False negative rates in Drosophila cell-based RNAi screens: a case study
2011-01-01
Background High-throughput screening using RNAi is a powerful gene discovery method but is often complicated by false positive and false negative results. Whereas false positive results associated with RNAi reagents has been a matter of extensive study, the issue of false negatives has received less attention. Results We performed a meta-analysis of several genome-wide, cell-based Drosophila RNAi screens, together with a more focused RNAi screen, and conclude that the rate of false negative results is at least 8%. Further, we demonstrate how knowledge of the cell transcriptome can be used to resolve ambiguous results and how the number of false negative results can be reduced by using multiple, independently-tested RNAi reagents per gene. Conclusions RNAi reagents that target the same gene do not always yield consistent results due to false positives and weak or ineffective reagents. False positive results can be partially minimized by filtering with transcriptome data. RNAi libraries with multiple reagents per gene also reduce false positive and false negative outcomes when inconsistent results are disambiguated carefully. PMID:21251254
The false-negative rate of sentinel node biopsy in patients with breast cancer: a meta-analysis
Pesek, Sarah; Ashikaga, Taka; Krag, Lars Erik; Krag, David
2012-01-01
Background/Purpose In sentinel node surgery for breast cancer, procedural accuracy is assessed by calculating the false-negative rate. It is important to measure this since there are potential adverse outcomes from missing node metastases. We performed a meta-analysis of published data to assess which method has achieved the lowest false-negative rate. Methods We found 3588 articles concerning sentinel nodes and breast cancer published from 1993 through mid-2011; 183 articles met our inclusion criteria. The studies described in these 183 articles included a total of 9306 patients. We grouped the studies by injection material and injection location. The false-negative rates were analyzed according to these groupings and also by the year in which the articles were published. Results There was significant variation in the false-negative rate over time with a trend to higher rates over time. There was significant variation related to injection material. The use of blue dye alone was associated with the highest false-negative rate. Inclusion of a radioactive tracer along with blue dye resulted in a significantly lower false-negative rate. Although there were variations in the false-negative rate according to injection location, none were significant. This meta-analysis also indicates a significant change over time in the false-negative rate. Discussion/Conclusions The use of blue dye should be accompanied by a radioactive tracer to achieve a significantly lower false-negative rate. Location of injection did not have a significant impact on the false-negative rate. Given the limitations of acquiring appropriate data, the false-negative rate should not be used as a metric for training or quality control. PMID:22569745
The problem of false positives and false negatives in violent video game experiments.
Ferguson, Christopher J
The problem of false positives and negatives has received considerable attention in behavioral research in recent years. The current paper uses video game violence research as an example of how such issues may develop in a field. Despite decades of research, evidence on whether violent video games (VVGs) contribute to aggression in players has remained mixed. Concerns have been raised in recent years that experiments regarding VVGs may suffer from both "false positives" and "false negatives." The current paper examines this issue in three sets of video game experiments, two sets of video game experiments on aggression and prosocial behaviors identified in meta-analysis, and a third group of recent null studies. Results indicated that studies of VVGs and aggression appear to be particularly prone to false positive results. Studies of VVGs and prosocial behavior, by contrast are heterogeneous and did not demonstrate any indication of false positive results. However, their heterogeneous nature made it difficult to base solid conclusions on them. By contrast, evidence for false negatives in null studies was limited, and little evidence emerged that null studies lacked power in comparison those highlighted in past meta-analyses as evidence for effects. These results are considered in light of issues related to false positives and negatives in behavioral science more broadly. Copyright © 2017 Elsevier Ltd. All rights reserved.
The impact of non-concordant self-report of substance use in clinical trials research.
Clark, C Brendan; Zyambo, Cosmas M; Li, Ye; Cropsey, Karen L
2016-07-01
Studies comparing self-report substance use data to biochemical verification generally demonstrate high rates of concordance. We argue that these rates are due to the relatively high true negative rate in the general population, and high degree of honestly in treatment seeking individuals. We hypothesized that high risk individuals not seeking treatment would demonstrate low concordance and a high false negative rate of self-reported substance use. A sample of 500 individuals from a smoking cessation clinical trial was assessed over 1 year. Assessments included semi-structured interviews, questionnaires (e.g. Addiction Severity Index, etc.), and urine drug screen assays (UDS). Generalized estimating equations (GEEs) were used to predict false negative reports for various substances across the study and determine the influence of substance use on the primary study outcome of smoking cessation. Participants demonstrated high false negative rates in reporting substances use, and the false negative rates increased as the study progressed. Established predictors of false negatives generalized to the current sample. High concordance and low false negative rates were found in self-report of nicotine use. A small but significant relationship was found in for effect of biochemically verified substance use on smoking cessation. Biochemical verification of substance use is needed in high risk populations involved in studies not directly related to the treatment of substance use, especially in populations with high threat of stigmatization. Testing should continue through the time period of the study for maximal identification of substance use. Copyright © 2016 Elsevier Ltd. All rights reserved.
Otgaar, Henry; Howe, Mark L; Muris, Peter
2017-09-01
We examined the creation of spontaneous and suggestion-induced false memories in maltreated and non-maltreated children. Maltreated and non-maltreated children were involved in a Deese-Roediger-McDermott false memory paradigm where they studied and remembered negative and neutral word lists. Suggestion-induced false memories were created using a misinformation procedure during which both maltreated and non-maltreated children viewed a negative video (i.e., bank robbery) and later received suggestive misinformation concerning the event. Our results showed that maltreated children had higher levels of spontaneous negative false memories but lower levels of suggestion-induced false memories as compared to non-maltreated children. Collectively, our study demonstrates that maltreatment both increases and decreases susceptibility to memory illusions depending on the type of false memory being induced. Statement of contribution What is already known on this subject? Trauma affects memory. It is unclear how trauma affects false memory. What does this study add? This study focuses on two types of false memories. © 2017 The Authors. British Journal of Developmental Psychology published by John Wiley & Sons Ltd on behalf of British Psychological Society.
Muthukumar, Alagarraju; Alatoom, Adnan; Burns, Susan; Ashmore, Jerry; Kim, Anne; Emerson, Brian; Bannister, Edward; Ansari, M Qasim
2015-01-01
To assess the false-positive and false-negative rates of a 4th-generation human immunodeficiency virus (HIV) assay, the Abbott ARCHITECT, vs 2 HIV 3rd-generation assays, the Siemens Centaur and the Ortho-Clinical Diagnostics Vitros. We examined 123 patient specimens. In the first phase of the study, we compared 99 specimens that had a positive screening result via the 3rd-generation Vitros assay (10 positive, 82 negative, and 7 indeterminate via confirmatory immunofluorescent assay [IFA]/Western blot [WB] testing). In the second phase, we assessed 24 HIV-1 RNA-positive (positive result via the nuclear acid amplification test [NAAT] and negative/indeterminate results via the WB test) specimens harboring acute HIV infection. The 4th-generation ARCHITECT assay yielded fewer false-positive results (n = 2) than the 3rd-generation Centaur (n = 9; P = .02) and Vitros (n = 82; P <.001) assays. One confirmed positive case had a false-negative result via the Centaur assay. When specimens from the 24 patients with acute HIV-1 infection were tested, the ARCHITECT assay yielded fewer false-negative results (n = 5) than the Centaur (n = 10) (P = .13) and the other 3rd-generation tests (n = 16) (P = .002). This study indicates that the 4th-generation ARCHITECT HIV assay yields fewer false-positive and false-negative results than the 3rd-generation HIV assays we tested. Copyright© by the American Society for Clinical Pathology (ASCP).
High false-negative rate of anti-HCV among Egyptian patients on regular hemodialysis.
El-Sherif, Assem; Elbahrawy, Ashraf; Aboelfotoh, Atef; Abdelkarim, Magdy; Saied Mohammad, Abdel-Gawad; Abdallah, Abdallah Mahmoud; Mostafa, Sadek; Elmestikawy, Amr; Elwassief, Ahmed; Salah, Mohamed; Abdelbaseer, Mohamed Ali; Abdelwahab, Kouka Saadeldin
2012-07-01
Routine serological testing for hepatitis C virus (HCV) infection among hemodialysis (HD) patients is currently recommended. A dilemma existed on the value of serology because some investigators reported a high rate of false-negative serologic testing. In this study, we aimed to detect the false-negative rate of anti-HCV among Egyptian HD patients. Seventy-eight HD patients, negative for anti-HCV, anti-HIV, and hepatitis B surface antigen, were tested for HCV RNA by reverse transcriptase polymerase chain reaction (RT-PCR). In the next step, the viral load was quantified by real-time PCR in RT-PCR-positive patients. Risk factors for HCV infection, as well as clinical and biochemical indicators of liver disease, were compared between false-negative and true-negative anti-HCV HD patients. The frequency of false-negative anti-HCV was 17.9%. Frequency of blood transfusion, duration of HD, dialysis at multiple centers, and diabetes mellitus were not identified as risk factors for HCV infection. The frequency of false-negative results had a linear relation to the prevalence of HCV infection in the HD units. Timely identification of HCV within dialysis units is needed in order to lower the risk of HCV spread within the HD units. The high false-negative rate of anti-HCV among HD patients in our study justifies testing of a large scale of patients for precious assessment of effectiveness of nucleic acid amplification technology testing in screening HD patient. © 2012 The Authors. Hemodialysis International © 2012 International Society for Hemodialysis.
Narita, Kazuto; Ishii, Yuuki; Vo, Phuc Thi Hong; Nakagawa, Fumiko; Ogata, Shinichi; Yamashita, Kunihiko; Kojima, Hajime; Itagaki, Hiroshi
2018-01-01
Recently, animal testing has been affected by increasing ethical, social, and political concerns regarding animal welfare. Several in vitro safety tests for evaluating skin sensitization, such as the human cell line activation test (h-CLAT), have been proposed. However, similar to other tests, the h-CLAT has produced false-negative results, including in tests for acid anhydride and water-insoluble chemicals. In a previous study, we demonstrated that the cause of false-negative results from phthalic anhydride was hydrolysis by an aqueous vehicle, with IL-8 release from THP-1 cells, and that short-time exposure to liquid paraffin (LP) dispersion medium could reduce false-negative results from acid anhydrides. In the present study, we modified the h-CLAT by applying this exposure method. We found that the modified h-CLAT is a promising method for reducing false-negative results obtained from acid anhydrides and chemicals with octanol-water partition coefficients (LogK ow ) greater than 3.5. Based on the outcomes from the present study, a combination of the original and the modified h-CLAT is suggested for reducing false-negative results. Notably, the combination method provided a sensitivity of 95% (overall chemicals) or 93% (chemicals with LogK ow > 2.0), and an accuracy of 88% (overall chemicals) or 81% (chemicals with LogK ow > 2.0). We found that the combined method is a promising evaluation scheme for reducing false-negative results seen in existing in vitro skin-sensitization tests. In the future, we expect a combination of original and modified h-CLAT to be applied in a newly developed in vitro test for evaluating skin sensitization.
Yang, Chi; Zhang, Shaojun; Yao, Lan; Fan, Lin
2018-05-01
Objective To investigate the diagnostic efficacy of an interferon-γ release assay, T-SPOT ® . TB, for diagnosing active tuberculosis (TB) and to identify risk factors for false-negative results. Methods This retrospective study enrolled consecutive patients with active TB and with non-TB respiratory diseases to evaluate the risk factors for false-negative results when using the T-SPOT ® . TB assay for the diagnosis of active TB. Patients with active TB were categorized as having confirmed pulmonary TB, clinically diagnosed pulmonary TB or extrapulmonary TB (EPTB). Results This study analysed 4964 consecutive patients; 2425 with active TB and 2539 with non-TB respiratory diseases. Multivariate logistic regression analyses identified the following five factors that were all associated with an increased false-negative rate with the T-SPOT ® . TB assay: increased age (odds ratio [OR] 1.018; 95% confidence interval [CI] 1.013, 1.024); decreased CD8+ count (OR 0.307; 95% CI 0.117, 0.803); negative sputum acid-fast bacilli (AFB) smear staining (OR 1.821; 95% CI 1.338, 2.477); negative mycobacterial cultures (OR 1.379; 95% CI 1.043, 1.824); and absence of EPTB (OR 1.291; 95% CI 1.026, 1.623). Conclusions Increased age, decreased CD8+ count, negative sputum AFB smear results, negative sputum mycobacterial cultures and absence of EPTB might lead to an increased false-negative rate when using the T-SPOT ® . TB assay.
Can missed breast cancer be recognized by regular peer auditing on screening mammography?
Pan, Huay-Ben; Yang, Tsung-Lung; Hsu, Giu-Cheng; Chiang, Chia-Ling; Huang, Jer-Shyung; Chou, Chen-Pin; Wang, Yen-Chi; Liang, Huei-Lung; Lee, San-Kan; Chou, Yi-Hong; Wong, Kam-Fai
2012-09-01
This study was conducted to investigate whether detectable missed breast cancers could be distinguished from truly false negative images in a mammographic screening by a regular peer auditing. Between 2004 and 2007, a total of 311,193 free nationwide biennial mammographic screenings were performed for 50- to 69-year-old women in Taiwan. Retrospectively comparing the records in Taiwan's Cancer registry, 1283 cancers were detected (4.1 per 1000). Of the total, 176 (0.6 per 1000) initial mammographic negative assessments were reported to have cancers (128 traditional films and 48 laser-printed digital images). We selected 186 true negative films (138 traditional films and 48 laser-printed ones) as control group. These were seeded into 4815 films of 2008 images to be audited in 2009. Thirty-four auditors interpreted all the films in a single-blind, randomized, pair-control study. The performance of 34 auditors was analyzed by chi-square test. A p value of < 0.05 was considered significant. Eight (6 traditional and 2 digital films) of the 176 false negative films were not reported by the auditors (missing rate of 4.5%). Of this total, 87 false negatives were reassessed as positive, while 29 of the 186 true negatives were reassessed as positive, making the overall performance of the 34 auditors in interpreting the false negatives and true negatives a specificity of 84.4% and sensitivity of 51.8%. The specificity and sensitivity in traditional films and laser-printed films were 98.6% versus 43.8% and 41.8% versus 78.3%, respectively. Almost 42% of the traditional false negative films had positive reassessment by the auditors, showing a significant difference from the initial screeners (p < 0.001). The specificity of their reinterpretation of laser-printed films was obviously low. Almost 42% of the false negative traditional films were judged as missed cancers in this study. A peer auditing should reduce the probability of missed cancers. 2012 Published by Elsevier B.V
van der Meulen, Miriam P; Lansdorp-Vogelaar, Iris; van Heijningen, Else-Mariëtte B; Kuipers, Ernst J; van Ballegooijen, Marjolein
2016-06-01
If some adenomas do not bleed over several years, they will cause systematic false-negative fecal immunochemical test (FIT) results. The long-term effectiveness of FIT screening has been estimated without accounting for such systematic false-negativity. There are now data with which to evaluate this issue. The authors developed one microsimulation model (MISCAN [MIcrosimulation SCreening ANalysis]-Colon) without systematic false-negative FIT results and one model that allowed a percentage of adenomas to be systematically missed in successive FIT screening rounds. Both variants were adjusted to reproduce the first-round findings of the Dutch CORERO FIT screening trial. The authors then compared simulated detection rates in the second screening round with those observed, and adjusted the simulated percentage of systematically missed adenomas to those data. Finally, the authors calculated the impact of systematic false-negative FIT results on the effectiveness of repeated FIT screening. The model without systematic false-negativity simulated higher detection rates in the second screening round than observed. These observed rates could be reproduced when assuming that FIT systematically missed 26% of advanced and 73% of nonadvanced adenomas. To reduce the false-positive rate in the second round to the observed level, the authors also had to assume that 30% of false-positive findings were systematically false-positive. Systematic false-negative FIT testing limits the long-term reduction of biennial FIT screening in the incidence of colorectal cancer (35.6% vs 40.9%) and its mortality (55.2% vs 59.0%) in participants. The results of the current study provide convincing evidence based on the combination of real-life and modeling data that a percentage of adenomas are systematically missed by repeat FIT screening. This impairs the efficacy of FIT screening. Cancer 2016;122:1680-8. © 2016 American Cancer Society. © 2016 American Cancer Society.
The role of attention at retrieval on the false recognition of negative emotional DRM lists.
Shah, Datin; Knott, Lauren M
2018-02-01
This study examined the role of attention at retrieval on the false recognition of emotional items using the Deese-Roediger-McDermott (DRM) paradigm. Previous research has shown that divided attention at test increases false remember judgements for neutral critical lures. However, no research has yet directly assessed emotional false memories when attention is manipulated at retrieval. To examine this, participants studied negative (low in valence and high in arousal) and neutral DRM lists and completed recognition tests under conditions of full and divided attention. Results revealed that divided attention at retrieval increased false remember judgements for all critical lures compared to retrieval under full attention, but in both retrieval conditions, false memories were greater for negative compared to neutral stimuli. We believe that this is due to reliance on a more easily accessible (meaning of the word) but less diagnostic form of source monitoring, amplified under conditions of divided attention.
A critical reappraisal of false negative sentinel lymph node biopsy in melanoma.
Manca, G; Romanini, A; Rubello, D; Mazzarri, S; Boni, G; Chiacchio, S; Tredici, M; Duce, V; Tardelli, E; Volterrani, D; Mariani, G
2014-06-01
Lymphatic mapping and sentinel lymph node biopsy (SLNB) have completely changed the clinical management of cutaneous melanoma. This procedure has been accepted worldwide as a recognized method for nodal staging. SLNB is able to accurately determine nodal basin status, providing the most useful prognostic information. However, SLNB is not a perfect diagnostic test. Several large-scale studies have reported a relatively high false-negative rate (5.6-21%), correctly defined as the proportion of false-negative results with respect to the total number of "actual" positive lymph nodes. The main purpose of this review is to address the technical issues that nuclear physicians, surgeons, and pathologists should carefully consider to improve the accuracy of SLNB by minimizing its false-negative rate. In particular, SPECT/CT imaging has demonstrated to be able to identify a greater number of sentinel lymph nodes (SLNs) than those found by planar lymphoscintigraphy. Furthermore, a unique definition in the international guidelines is missing for the operational identification of SLNs, which may be partly responsible for this relatively high false-negative rate of SLNB. Therefore, it is recommended for the scientific community to agree on the radioactive counting rate threshold so that the surgeon can be better radioguided to detect all the lymph nodes which are most likely to harbor metastases. Another possible source of error may be linked to the examination of the harvested SLNs by conventional histopathological methods. A more careful and extensive SLN analysis (e.g. molecular analysis by RT-PCR) is able to find more positive nodes, so that the false-negative rate is reduced. Older age at diagnosis, deeper lesions, histologic ulceration, head-neck anatomical location of primary lesions are the clinical factors associated with false-negative SLNBs in melanoma patients. There is still much controversy about the clinical significance of a false-negative SLNB on the prognosis of melanoma patients. Indeed, most studies have failed to show that there is worse melanoma-specific survival for false-negative compared to true-positive SLNB patients.
Singh, Gurmukh
2017-01-01
Background Serum free light chain assay (SFLCA) and κ/λ ratio, and protein electrophoretic methods are used in the diagnosis and monitoring of monoclonal gammopathies. Methods Results for serum free light chains, serum and urine protein electrophoreses and immunofixation electrophoreses in 468 patients with a diagnosis of monoclonal gammopathy were compared. The results of the two methods were graded as concordant, non-concordant or discordant with the established diagnoses to assess the relative performance of the methods. Results of κ/λ ratio in samples with monoclonal protein detectable by electrophoretic methods were also analyzed. Results Protein electrophoreses results were concordant with the established diagnoses significantly more often than κ/λ ratio. The false negative rate for κ/λ ratio was higher than that for electrophoretic methods. κ/λ ratio was falsely negative in about 27% of the 1,860 samples with detectable monoclonal immunoglobulin. The false negative rate was higher in lesions with lambda chains (32%) than those with kappa chains (24%). The false negative rate for κ/λ ratio was over 55% in samples with monoclonal gammopathy of undetermined significance. Even at first encounter, the false negative rates for κ/λ ratios for monoclonal gammopathy of undetermined significance, smoldering myeloma and multiple myeloma were 66.98%, 23.08%, and 30.15%, respectively, with false negative rate for lambda chain lesions being higher. Conclusions Electrophoretic studies of serum and urine are superior to SFLCA and κ/λ ratio. Abnormal κ/λ ratio, per se, is not diagnostic of monoclonal gammopathy. A normal κ/λ ratio does not exclude monoclonal gammopathy. False negative rates for lesions with lambda chain are higher than those for lesions with kappa chains. Electrophoretic studies of urine are underutilized. Clinical usefulness and medical necessity of SFLCA and κ/λ ratio is of questionable value in routine clinical testing. PMID:27924175
Singh, Gurmukh
2017-01-01
Serum free light chain assay (SFLCA) and κ/λ ratio, and protein electrophoretic methods are used in the diagnosis and monitoring of monoclonal gammopathies. Results for serum free light chains, serum and urine protein electrophoreses and immunofixation electrophoreses in 468 patients with a diagnosis of monoclonal gammopathy were compared. The results of the two methods were graded as concordant, non-concordant or discordant with the established diagnoses to assess the relative performance of the methods. Results of κ/λ ratio in samples with monoclonal protein detectable by electrophoretic methods were also analyzed. Protein electrophoreses results were concordant with the established diagnoses significantly more often than κ/λ ratio. The false negative rate for κ/λ ratio was higher than that for electrophoretic methods. κ/λ ratio was falsely negative in about 27% of the 1,860 samples with detectable monoclonal immunoglobulin. The false negative rate was higher in lesions with lambda chains (32%) than those with kappa chains (24%). The false negative rate for κ/λ ratio was over 55% in samples with monoclonal gammopathy of undetermined significance. Even at first encounter, the false negative rates for κ/λ ratios for monoclonal gammopathy of undetermined significance, smoldering myeloma and multiple myeloma were 66.98%, 23.08%, and 30.15%, respectively, with false negative rate for lambda chain lesions being higher. Electrophoretic studies of serum and urine are superior to SFLCA and κ/λ ratio. Abnormal κ/λ ratio, per se , is not diagnostic of monoclonal gammopathy. A normal κ/λ ratio does not exclude monoclonal gammopathy. False negative rates for lesions with lambda chain are higher than those for lesions with kappa chains. Electrophoretic studies of urine are underutilized. Clinical usefulness and medical necessity of SFLCA and κ/λ ratio is of questionable value in routine clinical testing.
Tamkus, Arvydas A; Rice, Kent S; McCaffrey, Michael T
2018-02-01
Although some authors have published case reports describing false negatives in intraoperative neurophysiological monitoring (IONM), a systematic review of causes of false-negative IONM results is lacking. The objective of this study was to analyze false-negative IONM findings in spine surgery. This is a retrospective cohort analysis. A cohort of 109 patients with new postoperative neurologic deficits was analyzed for possible false-negative IONM reporting. The causes of false-negative IONM reporting were determined. From a cohort of 62,038 monitored spine surgeries, 109 consecutive patients with new postoperative neurologic deficits were reviewed for IONM alarms. Intraoperative neurophysiological monitoring alarms occurred in 87 of 109 surgeries. Nineteen patients with new postoperative neurologic deficits did not have an IONM alarm and surgeons were not warned. In addition, three patients had no interpretable IONM baseline data and no alarms were possible for the duration of the surgery. Therefore, 22 patients were included in the study. The absence of IONM alarms during these 22 surgeries had different origins: "true" false negatives where no waveform changes meeting the alarm criteria occurred despite the appropriate IONM (7); a postoperative development of a deficit (6); failure to monitor the pathway, which became injured (5); the absence of interpretable IONM baseline data which precluded any alarm (3); and technical IONM application issues (1). Overall, the rate of IONM method failing to predict the patient's outcome was very low (0.04%, 22/62,038). Minimizing false negatives requires the application of a proper IONM technique with the limitations of each modality considered in their selection and interpretation. Multimodality IONM provides the most inclusive information, and although it might be impractical to monitor every neural structure that can be at risk, a thorough preoperative consideration of available IONM modalities is important. Delayed development of postoperative deficits cannot be predicted by IONM. Absent baseline IONM data should be treated as an alarm when inconsistent with the patient's preoperative neurologic status. Alarm criteria for IONM may need to be refined for specific procedures and deserves continued study. Copyright © 2017 Elsevier Inc. All rights reserved.
Discrete emotion-congruent false memories in the DRM paradigm.
Bland, Cassandra E; Howe, Mark L; Knott, Lauren
2016-08-01
Research has shown that false-memory production is enhanced for material that is emotionally congruent with the mood of the participant at the time of encoding. So far this research has only been conducted to examine the influence of generic negative affective mood states and generic negative stimuli on false-memory production. In addition, much of the research is limited as it focuses on valence and arousal dimensions, and fails to take into account the more comprehensive nature of emotions. The current study demonstrates that this effect goes beyond general negative or positive moods and acts at a more discrete emotional level. Participants underwent a standard emotion-induction procedure before listening to negative emotional or neutral associative word lists. The emotions induced, negative word lists, and associated nonpresented critical lures, were related to either fear or anger, 2 negative valence emotions that are also both high in arousal. Results showed that when valence and arousal are controlled for, false memories are more likely to be produced for discrete emotionally congruent compared with incongruent materials. These results support spreading activation theories of false remembering and add to our understanding of the adaptive nature of false-memory production. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Stirling, Paul; Faroug, Radwane; Amanat, Suheil; Ahmed, Abdulkhaled; Armstrong, Malcolm; Sharma, Pankaj; Qamruddin, Ahmed
2014-01-01
We quantify the false-negative diagnostic rate of septic arthritis using Gram-stain microscopy of synovial fluid and compare this to values reported in the peer-reviewed literature. We propose a method of improving the diagnostic value of Gram-stain microscopy using Lithium Heparin containers that prevent synovial fluid coagulation. Retrospective study of the Manchester Royal Infirmary microbiology database of patients undergoing synovial fluid Gram-stain and culture between December 2003 and March 2012 was undertaken. The initial cohort of 1896 synovial fluid analyses for suspected septic arthritis was reduced to 143 after exclusion criteria were applied. Analysis of our Gram-stain microscopy yielded 111 false-negative results from a cohort size of 143 positive synovial fluid cultures, giving a false-negative rate of 78%. We report a false-negative rate of Gram-stain microscopy for septic arthritis of 78%. Clinicians should therefore avoid the investigation until a statistically significant data set confirms its efficacy. The investigation's value could be improved by using Lithium Heparin containers to collect homogenous synovial fluid samples. Ongoing research aims to establish how much this could reduce the false-negative rate.
Whitson, Bryan A; Groth, Shawn S; Odell, David D; Briones, Eleazar P; Maddaus, Michael A; D'Cunha, Jonathan; Andrade, Rafael S
2013-05-01
Mediastinal staging in patients with non-small cell lung cancer (NSCLC) with endobronchial ultrasound-guided fine-needle aspiration (EBUS-FNA) requires a high negative predictive value (NPV) (ie, low false negative rate). We provide a conservative calculation of NPV that calls for caution in the interpretation of EBUS results. We retrospectively analyzed our prospectively gathered database (January 2007 to November 2011) to include NSCLC patients who underwent EBUS-FNA for mediastinal staging. We excluded patients with metastatic NSCLC and other malignancies. We assessed FNAs with rapid on-site evaluation (ROSE). The calculation of NPV is NPV = true negatives/true negatives + false negatives. However, this definition ignores nondiagnostic samples. Nondiagnostic samples should be added to the NPV denominator because decisions based on nondiagnostic samples could be flawed. We conservatively calculated NPV for EBUS-FNA as NPV = true negatives/true negatives + false negatives + nondiagnostic. We defined false negatives as negative FNAs but NSCLC-positive surgical biopsy of the same site. Nondiagnostic FNAs were nonrepresentative of lymphoid tissue. We compared diagnostic performance with the inclusion and exclusion of nondiagnostic procedures. We studied 120 patients with NSCLC who underwent EBUS-FNA; 5 patients had false negative findings and 10 additional patients had nondiagnostic results. The NPV with and without inclusion of nondiagnostic samples was 65.9% and 85.3%, respectively. The inclusion of nondiagnostic specimens into the conservative, worst-case-scenario calculation of NPV for EBUS-FNA in NSCLC lowers the NPV from 85.3% to 65.9%. The true NPV is likely higher than 65.9% as few nondiagnostic specimens are false negatives. Caution is imperative for the safe application of EBUS-FNA in NSCLC staging. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Porter, Stephen; Taylor, Kristian; Ten Brinke, Leanne
2008-01-01
Despite a large body of false memory research, little has addressed the potential influence of an event's emotional content on susceptibility to false recollections. The Paradoxical Negative Emotion (PNE) hypothesis predicts that negative emotion generally facilitates memory but also heightens susceptibility to false memories. Participants were asked whether they could recall 20 "widely publicised" public events (half fictitious) ranging in emotional valence, with or without visual cues. Participants recalled a greater number of true negative events (M=3.31/5) than true positive (M=2.61/5) events. Nearly everyone (95%) came to recall at least one false event (M=2.15 false events recalled). Further, more than twice as many participants recalled any false negative (90%) compared to false positive (41.7%) events. Negative events, in general, were associated with more detailed memories and false negative event memories were more detailed than false positive event memories. Higher dissociation scores were associated with false recollections of negative events, specifically.
Wiwanitkit, Viroj; Udomsantisuk, Nibhond; Boonchalermvichian, Chaiyaporn
2005-06-01
The aim of this study was to evaluate the diagnostic properties of urine Gram stain and urine microscopic examination for screening for urinary tract infection (UTI), and to perform an additional cost utility analysis. This descriptive study was performed on 95 urine samples sent for urine culture to the Department of Microbiology, Faculty of Medicine, Chulalongkorn University. The first part of the study was to determine the diagnostic properties of two screening tests (urine Gram stain and urine microscopic examination). Urine culture was set as the gold standard and the results from both methods were compared to this. The second part of this study was to perform a cost utility analysis. The sensitivity of urine Gram stain was 96.2%, the specificity 93.0%, the positive predictive value 94.3% and the negative predictive value 95.2%. False positives occurred with a frequency of 7.0% and false negatives 3.8%. For the microscopic examination, the sensitivity was 65.4%, specificity 74.4%, positive predictive value 75.6% and negative predictive value 64.0%. False positives occurred with a frequency of 25.6% and false negatives 34.6%. Combining urine Gram stain and urine microscopic examination, the sensitivity was 98.1%, specificity 74.4%, positive predictive value 82.3% and negative predictive value 97.0%. False positives occurred with a frequency of 25.6% and false negatives 1.9%. However, the cost per utility of the combined method was higher than either urine microscopic examination or urine Gram stain alone. Urine Gram stain provided the lowest cost per utility. Economically, urine Gram stain is the proper screening tool for presumptive diagnosis of UTI.
Negative feedback from maternal signals reduces false alarms by collectively signalling offspring.
Hamel, Jennifer A; Cocroft, Reginald B
2012-09-22
Within animal groups, individuals can learn of a predator's approach by attending to the behaviour of others. This use of social information increases an individual's perceptual range, but can also lead to the propagation of false alarms. Error copying is especially likely in species that signal collectively, because the coordination required for collective displays relies heavily on social information. Recent evidence suggests that collective behaviour in animals is, in part, regulated by negative feedback. Negative feedback may reduce false alarms by collectively signalling animals, but this possibility has not yet been tested. We tested the hypothesis that negative feedback increases the accuracy of collective signalling by reducing the production of false alarms. In the treehopper Umbonia crassicornis, clustered offspring produce collective signals during predator attacks, advertising the predator's location to the defending mother. Mothers signal after evicting the predator, and we show that this maternal communication reduces false alarms by offspring. We suggest that maternal signals elevate offspring signalling thresholds. This is, to our knowledge, the first study to show that negative feedback can reduce false alarms by collectively behaving groups.
Paek, Se Hyun; Kim, Byung Seup; Kang, Kyung Ho; Kim, Hee Sung
2017-11-13
The BRAF V600E mutation is highly specific for papillary thyroid carcinoma (PTC). A test for this mutation can increase the diagnostic accuracy of fine-needle aspiration cytology (FNAC), but a considerably high false-negative rate for the BRAF V600E mutation on FNAC has been reported. In this study, we investigated the risk factors associated with false-negative BRAF V600E mutation results on FNAC. BRAF V600E mutation results of 221 PTC nodules between December 2011 and June 2013 were retrospectively reviewed. BRAF V600E mutation results on both preoperative FNAC and postoperative formalin-fixed, paraffin-embedded (FFPE) samples were compared. We investigated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of BRAF V600E mutation results on FNAC. And, we identified the risk factors associated with false-negative results. Of 221 PTC nodules, 150 (67.9%) on FNAC and 185 (83.7%) on FFPE samples were BRAF V600E mutation positive. The sensitivity, specificity, PPV, and NPV for BRAF V600E mutation testing with FNAC were 80.5, 97.2, 99.3, and 49.3%, respectively. Thirty-six (16.3%) BRAF V600E mutation-negative nodules on FNAC were mutation positive on FFPE sample analysis. Risk factors for these false-negative results were age, indeterminate FNAC results (nondiagnostic, atypia of undetermined significance (AUS), and findings suspicious for PTC), and PTC subtype. False-negative rate of BRAF mutation testing with FNAC for thyroid nodules is increased in cases of old age, indeterminate FNAC pathology results, and certain PTC subtypes. Therapeutic surgery can be considered for these cases. A well-designed prospective study with informed consent of patients will be essential for more informative results.
Sentinel lymph node mapping in melanoma: the issue of false-negative findings.
Manca, Gianpiero; Rubello, Domenico; Romanini, Antonella; Boni, Giuseppe; Chiacchio, Serena; Tredici, Manuel; Mazzarri, Sara; Duce, Valerio; Colletti, Patrick M; Volterrani, Duccio; Mariani, Giuliano
2014-07-01
Management of cutaneous melanoma has changed after introduction in the clinical routine of sentinel lymph node biopsy (SLNB) for nodal staging. By defining the nodal basin status, SLNB provides a powerful prognostic information. Nevertheless, some debate still surrounds the accuracy of this procedure in terms of false-negative rate. Several large-scale studies have reported a relatively high false-negative rate (5.6%-21%), correctly defined as the proportion of false-negative results with respect to the total number of "actual" positive lymph nodes. In this review, we identified all the technical aspects that the nuclear medicine physician, the surgeon, and the pathologist should take into account to improve accuracy of the procedure and minimize the false-negative rate. In particular, SPECT/CT imaging detects more SLNs than those found by planar lymphoscintigraphy. Furthermore, the nuclear medicine community should reach a consensus on the radioactive counting rate threshold to better guide the surgeon in identifying the lymph nodes with the highest likelihood of housing metastases ("true biologic SLNs"). Analysis of the harvested SLNs by conventional techniques is also a further potential source for error. More accurate SLN analysis (eg, molecular analysis by reverse transcriptase-polymerase chain reaction) and more extensive SLN sampling identify more positive nodes, thus reducing the false-negative rate.The clinical factors identifying patients at higher-risk local recurrence after a negative SLNB include older age at diagnosis, deeper lesions, histological ulceration, and head-neck anatomic location of the primary lesion.The clinical impact of a false-negative SLNB on the prognosis of melanoma patients remains controversial, because the majority of studies have failed to demonstrate overall statistically significant disadvantage in melanoma-specific survival for false-negative SLNB patients compared with true-positive SLNB patients.When new more effective drugs will be available in the adjuvant setting for stage III melanoma patients, the implication of an accurate staging procedure for the sentinel lymph nodes will be crucial for both patients and clinicians. Standardization and accuracy of SLN identification, removal, and analysis are required.
Effects of depressive disorder on false memory for emotional information.
Yeh, Zai-Ting; Hua, Mau-Sun
2009-01-01
This study explored with a false memory paradigm whether (1) depressed patients revealed more false memories and (2) whether more negative false than positive false recognition existed in subjects with depressive disorders. Thirty-two patients suffering from a major depressive episode (DSM-IV criteria), and 30 age- and education-matched normal control subjects participated in this study. After the presentation of a list of positive, negative, and neutral association items in the learning phase, subjects were asked to give a yes/no response in the recognition phase. They were also asked to rate 81 recognition items with emotional valence scores. The results revealed more negative false memories in the clinical depression group than in the normal control group; however, we did not find more negative false memories than positive ones in patients. When compared with the normal group, a more conservative response criterion for positive items was evident in patient groups. It was also found that when compared with the normal group, the subjects in the depression group perceived the positive items as less positive. On the basis of present results, it is suggested that depressed subjects judged the emotional information with criteria different from normal individuals, and patients' emotional memory intensity is attenuated by their mood.
Emotions and false memories: valence or arousal?
Corson, Yves; Verrier, Nadège
2007-03-01
The effects of mood on false memories have not been studied systematically until recently. Some results seem to indicate that negative mood may reduce false recall and thus suggest an influence of emotional valence on false memory. The present research tested the effects of both valence and arousal on recall and recognition and indicates that the effect is actually due to arousal. In fact, whether participants' mood is positive, negative, or neutral, false memories are significantly more frequent under conditions of high arousal than under conditions of low arousal.
Bruijn, Merel M C; Hermans, Frederik J R; Vis, Jolande Y; Wilms, Femke F; Oudijk, Martijn A; Kwee, Anneke; Porath, Martina M; Oei, Guid; Scheepers, Hubertina C J; Spaanderman, Marc E A; Bloemenkamp, Kitty W M; Haak, Monique C; Bolte, Antoinette C; Vandenbussche, Frank P H A; Woiski, Mallory D; Bax, Caroline J; Cornette, Jérôme M J; Duvekot, Johannes J; Bijvank, Bas W A N I J; van Eyck, Jim; Franssen, Maureen T M; Sollie, Krystyna M; van der Post, Joris A M; Bossuyt, Patrick M M; Kok, Marjolein; Mol, Ben W J; van Baaren, Gert-Jan
2017-02-01
Objective We assessed the influence of external factors on false-positive, false-negative, and invalid fibronectin results in the prediction of spontaneous delivery within 7 days. Methods We studied symptomatic women between 24 and 34 weeks' gestational age. We performed uni- and multivariable logistic regression to estimate the effect of external factors (vaginal soap, digital examination, transvaginal sonography, sexual intercourse, vaginal bleeding) on the risk of false-positive, false-negative, and invalid results, using spontaneous delivery within 7 days as the outcome. Results Out of 708 women, 237 (33%) had a false-positive result; none of the factors showed a significant association. Vaginal bleeding increased the proportion of positive fetal fibronectin (fFN) results, but was significantly associated with a lower risk of false-positive test results (odds ratio [OR], 0.22; 95% confidence intervals [CI], 0.12-0.39). Ten women (1%) had a false-negative result. None of the investigated factors was significantly associated with a significantly higher risk of false-negative results. Twenty-one tests (3%) were invalid; only vaginal bleeding showed a significant association (OR, 4.5; 95% CI, 1.7-12). Conclusion The effect of external factors on the performance of qualitative fFN testing is limited, with vaginal bleeding as the only factor that reduces its validity. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piepel, Gregory F.; Hutchison, Janine R.
2014-04-16
This report describes the experimental design for a laboratory study to quantify the recovery efficiencies and false negative rates of a validated, macrofoam swab sampling method for low concentrations of Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus (BG) spores on four surface materials (stainless steel, glass, vinyl tile, plastic light cover panel). Two analytical methods (plating/counting and polymerase chain reaction) will be used. Only one previous study has investigated false negative as a function of affecting test factors. The surrogates BAS and BG have not been tested together in the same study previously. Hence, this study will provide for completingmore » gaps in the available information on the performance of macrofoam swab sampling at low concentrations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piepel, Gregory F.; Hutchison, Janine R.
This report describes the experimental design for a laboratory study to quantify the recovery efficiencies and false negative rates of a validated, macrofoam-swab sampling method for low concentrations of Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus (BG) spores on four surface materials (stainless steel, glass, vinyl tile, plastic light cover panel). Two analytical methods (culture and polymerase chain reaction) will be used. Only one previous study has investigated how the false negative rate depends on test factors. The surrogates BAS and BG have not been tested together in the same study previously. Hence, this study will provide for completing gapsmore » in the available information on the performance of macrofoam-swab sampling at low concentrations.« less
False Memories for Affective Information in Schizophrenia.
Fairfield, Beth; Altamura, Mario; Padalino, Flavia A; Balzotti, Angela; Di Domenico, Alberto; Mammarella, Nicola
2016-01-01
Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the to-be-remembered material and false memory occurrence has not yet been studied. In this study, 24 patients and 24 healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative, or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls ( p < 0.05) when remembering episodes with positive or negative outcomes. The effect of valence was apparent in the patient group. For example, it did not affect the production causal false memories ( p > 0.05) resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e., neutral episodes yielded a higher degree of errors than positive and negative episodes). Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved.
False Memories for Affective Information in Schizophrenia
Fairfield, Beth; Altamura, Mario; Padalino, Flavia A.; Balzotti, Angela; Di Domenico, Alberto; Mammarella, Nicola
2016-01-01
Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the to-be-remembered material and false memory occurrence has not yet been studied. In this study, 24 patients and 24 healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative, or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls (p < 0.05) when remembering episodes with positive or negative outcomes. The effect of valence was apparent in the patient group. For example, it did not affect the production causal false memories (p > 0.05) resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e., neutral episodes yielded a higher degree of errors than positive and negative episodes). Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved. PMID:27965600
Mood-congruent false memories persist over time.
Knott, Lauren M; Thorley, Craig
2014-01-01
In this study, we examined the role of mood-congruency and retention interval on the false recognition of emotion laden items using the Deese/Roediger-McDermott (DRM) paradigm. Previous research has shown a mood-congruent false memory enhancement during immediate recognition tasks. The present study examined the persistence of this effect following a one-week delay. Participants were placed in a negative or neutral mood, presented with negative-emotion and neutral-emotion DRM word lists, and administered with both immediate and delayed recognition tests. Results showed that a negative mood state increased remember judgments for negative-emotion critical lures, in comparison to neutral-emotion critical lures, on both immediate and delayed testing. These findings are discussed in relation to theories of spreading activation and emotion-enhanced memory, with consideration of the applied forensic implications of such findings.
Generalized site occupancy models allowing for false positive and false negative errors
Royle, J. Andrew; Link, W.A.
2006-01-01
Site occupancy models have been developed that allow for imperfect species detection or ?false negative? observations. Such models have become widely adopted in surveys of many taxa. The most fundamental assumption underlying these models is that ?false positive? errors are not possible. That is, one cannot detect a species where it does not occur. However, such errors are possible in many sampling situations for a number of reasons, and even low false positive error rates can induce extreme bias in estimates of site occupancy when they are not accounted for. In this paper, we develop a model for site occupancy that allows for both false negative and false positive error rates. This model can be represented as a two-component finite mixture model and can be easily fitted using freely available software. We provide an analysis of avian survey data using the proposed model and present results of a brief simulation study evaluating the performance of the maximum-likelihood estimator and the naive estimator in the presence of false positive errors.
Dehon, Hedwige; Larøi, Frank; Van der Linden, Martial
2010-10-01
This study examined the influence of emotional valence on the production of DRM false memories (Roediger & McDermott, 1995). Participants were presented with neutral, positive, or negative DRM lists for a later recognition (Experiment 1) or recall (Experiment 2) test. In both experiments, confidence and recollective experience (i.e., "Remember-Know" judgments; Tulving, 1985) were also assessed. Results consistently showed that, compared with neutral lists, affective lists induced more false recognition and recall of nonpresented critical lures. Moreover, although confidence ratings did not differ between the false remembering from the different kinds of lists, "Remember" responses were more often associated with negative than positive and neutral false remembering of the critical lures. In contrast, positive false remembering of the critical lures was more often associated with "Know" responses. These results are discussed in light of the Paradoxical Negative Emotion (PNE) hypothesis (Porter, Taylor, & ten Bricke, 2008). (PsycINFO Database Record (c) 2010 APA, all rights reserved).
Chen, Qianting; Dai, Congling; Zhang, Qianjun; Du, Juan; Li, Wen
2016-10-01
To study the prediction performance evaluation with five kinds of bioinformatics software (SIFT, PolyPhen2, MutationTaster, Provean, MutationAssessor). From own database for genetic mutations collected over the past five years, Chinese literature database, Human Gene Mutation Database, and dbSNP, 121 missense mutations confirmed by functional studies, and 121 missense mutations suspected to be pathogenic by pedigree analysis were used as positive gold standard, while 242 missense mutations with minor allele frequency (MAF)>5% in dominant hereditary diseases were used as negative gold standard. The selected mutations were predicted with the five software. Based on the results, the performance of the five software was evaluated for their sensitivity, specificity, positive predict value, false positive rate, negative predict value, false negative rate, false discovery rate, accuracy, and receiver operating characteristic curve (ROC). In terms of sensitivity, negative predictive value and false negative rate, the rank was MutationTaster, PolyPhen2, Provean, SIFT, and MutationAssessor. For specificity and false positive rate, the rank was MutationTaster, Provean, MutationAssessor, SIFT, and PolyPhen2. For positive predict value and false discovery rate, the rank was MutationTaster, Provean, MutationAssessor, PolyPhen2, and SIFT. For area under the ROC curve (AUC) and accuracy, the rank was MutationTaster, Provean, PolyPhen2, MutationAssessor, and SIFT. The prediction performance of software may be different when using different parameters. Among the five software, MutationTaster has the best prediction performance.
Herbert, Cornelia; Kübler, Andrea
2011-01-01
The present study investigated event-related brain potentials elicited by true and false negated statements to evaluate if discrimination of the truth value of negated information relies on conscious processing and requires higher-order cognitive processing in healthy subjects across different levels of stimulus complexity. The stimulus material consisted of true and false negated sentences (sentence level) and prime-target expressions (word level). Stimuli were presented acoustically and no overt behavioral response of the participants was required. Event-related brain potentials to target words preceded by true and false negated expressions were analyzed both within group and at the single subject level. Across the different processing conditions (word pairs and sentences), target words elicited a frontal negativity and a late positivity in the time window from 600-1000 msec post target word onset. Amplitudes of both brain potentials varied as a function of the truth value of the negated expressions. Results were confirmed at the single-subject level. In sum, our results support recent suggestions according to which evaluation of the truth value of a negated expression is a time- and cognitively demanding process that cannot be solved automatically, and thus requires conscious processing. Our paradigm provides insight into higher-order processing related to language comprehension and reasoning in healthy subjects. Future studies are needed to evaluate if our paradigm also proves sensitive for the detection of consciousness in non-responsive patients.
The effect of mood on false memory for emotional DRM word lists.
Zhang, Weiwei; Gross, Julien; Hayne, Harlene
2017-04-01
In the present study, we investigated the effect of participants' mood on true and false memories of emotional word lists in the Deese-Roediger-McDermott (DRM) paradigm. In Experiment 1, we constructed DRM word lists in which all the studied words and corresponding critical lures reflected a specified emotional valence. In Experiment 2, we used these lists to assess mood-congruent true and false memory. Participants were randomly assigned to one of three induced-mood conditions (positive, negative, or neutral) and were presented with word lists comprised of positive, negative, or neutral words. For both true and false memory, there was a mood-congruent effect in the negative mood condition; this effect was due to a decrease in true and false recognition of the positive and neutral words. These findings are consistent with both spreading-activation and fuzzy-trace theories of DRM performance and have practical implications for our understanding of the effect of mood on memory.
The value of a transformation zone component in anal cytology to detect HSIL.
Roberts, Jennifer M; Jin, Fengyi; Thurloe, Julia K; Ekman, Deborah; Adams, Marjorie K; McDonald, Ross L; Biro, Clare; Poynten, I Mary; Grulich, Andrew E; Farnsworth, Annabelle
2016-08-01
In a cytology-based screening program intended to prevent anal cancer, the anal transformation zone (TZ) should be adequately sampled because it is the site most susceptible to the development of the cancer precursor, high-grade squamous intraepithelial lesion (HSIL). An adequate TZ component is defined as comprising at least 10 rectal columnar or squamous metaplastic cells. In the current study, the authors examined whether the presence of a TZ component in anal cytology correlated with the detection of histological HSIL. In a natural history study of anal human papillomavirus infection in homosexual men, all participants underwent liquid-based cytology and high-resolution anoscopy (HRA) with or without biopsy at each visit. True-negative cytology (negative cytology with non-HSIL biopsy or negative HRA), false-negative cytology (negative cytology with HSIL biopsy), and true-positive cytology (abnormal cytology with HSIL biopsy) were compared with regard to the presence or absence of a TZ component. Of 617 participants, baseline results included 155 true-positive results, 191 true-negative results, and 31 false-negative results. The absence of an adequate TZ component was found to be significantly higher for false-negative (32.3%) than for either true-positive (11.0%; P = .0034) or true-negative (13.1%; P = .0089) results. Significantly more false-negative cases lacked a TZ component compared with either true-positive or true-negative cases. TZ cells may be an important indicator of sample quality for anal cytology because, unlike cervical sampling, the anal canal is not visualized during cytology sampling. Cancer Cytopathol 2016;124:596-601. © 2016 American Cancer Society. © 2016 American Cancer Society.
Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun
2018-06-01
Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P < .05). The diagnostic accuracy was best in nodules of 5 to 10 mm in diameter. The sensitivity, accuracy, PPV, and LR for negative US-guided FNA results were better in nodules with a size range of 5 to 15 mm. The specificity, negative predictive value (NPV), and LR for positive results and the Youden index rose with increasing nodule size. Seventeen false-positive and 60 false-negative results were found in this study. The false-negative rate rose with increasing nodule size. However, the false-positive rate was highest in the group containing the smallest nodules. Nodules with circumscribed margins and those that were nonsolid and nonhypoechoic and had no microcalcifications correlated with Bethesda I FNA results. Nodules with circumscribed margins and those that were nonsolid, heterogeneous, and nonhypoechoic and had increased vascularity correlated with false-negative FNA results. Borders correlated with Bethesda I false-negative and false-positive FNA results. Tiny nodules (≤5 mm) with obscure borders tended to yield false-positive FNA results. Large nodules (>20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.
A Closer Look at Self-Reported Suicide Attempts: False Positives and False Negatives
ERIC Educational Resources Information Center
Ploderl, Martin; Kralovec, Karl; Yazdi, Kurosch; Fartacek, Reinhold
2011-01-01
The validity of self-reported suicide attempt information is undermined by false positives (e.g., incidences without intent to die), or by unreported suicide attempts, referred to as false negatives. In a sample of 1,385 Austrian adults, we explored the occurrence of false positives and false negatives with detailed, probing questions. Removing…
Koita, Ousmane A; Doumbo, Ogobara K; Ouattara, Amed; Tall, Lalla K; Konaré, Aoua; Diakité, Mahamadou; Diallo, Mouctar; Sagara, Issaka; Masinde, Godfred L; Doumbo, Safiatou N; Dolo, Amagana; Tounkara, Anatole; Traoré, Issa; Krogstad, Donald J
2012-02-01
We identified 480 persons with positive thick smears for asexual Plasmodium falciparum parasites, of whom 454 had positive rapid diagnostic tests (RDTs) for the histidine-rich protein 2 (HRP2) product of the hrp2 gene and 26 had negative tests. Polymerase chain reaction (PCR) amplification for the histidine-rich repeat region of that gene was negative in one-half (10/22) of false-negative specimens available, consistent with spontaneous deletion. False-negative RDTs were found only in persons with asymptomatic infections, and multiplicities of infection (MOIs) were lower in persons with false-negative RDTs (both P < 0.001). These results show that parasites that fail to produce HRP2 can cause patent bloodstream infections and false-negative RDT results. The importance of these observations is likely to increase as malaria control improves, because lower MOIs are associated with false-negative RDTs and false-negative RDTs are more frequent in persons with asymptomatic infections. These findings suggest that the use of HRP2-based RDTs should be reconsidered.
Sievert, Lynnette L; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E
2010-01-01
The aims of this study were to test for a diurnal pattern in hot flashes in a multiethnic population living in a hot, humid environment and to examine the rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Study participants aged 45 to 55 years were recruited from the general population of Hilo, HI. Women wore a Biolog hot flash monitor (UFI, Morro Bay, CA), kept a diary for 24 hours, and also participated in 3-hour laboratory measures (n = 199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true-positive readings. Subjective hot flashes were considered the standard for computing false-positive and false-negative readings. True-positive, false-positive, and false-negative readings were compared across ethnic groups by chi analyses. Frequencies of sternal, nuchal, and subjective hot flashes peaked at 1500 +/- 1 hours with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true-positive measures, but nonsternal electrodes picked up more false-positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true-positive or false-positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false-negative measures). The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo were similar to results from more temperate environments. Lack of variation in sternal versus nonsternal measures and in true-positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns.
False negative cytology in large thyroid nodules.
Giles, Wesley H; Maclellan, Reid A; Gawande, Atul A; Ruan, Daniel T; Alexander, Erik K; Moore, Francis D; Cho, Nancy L
2015-01-01
Controversy exists regarding the accuracy of fine-needle aspiration (FNA) in large thyroid nodules. Recent surgical series have documented false-negative rates ranging from 0.7 to 13 %. We examined the accuracy of benign FNA cytology in patients with thyroid nodules ≥3 cm who underwent surgical resection and identified features characteristic of false-negative results. We retrospectively studied all thyroidectomy specimens between January 2009 and October 2011 and identified nodules ≥3 cm with corresponding benign preoperative FNA cytology. We collected clinical information regarding patient demographics, nodule size, symptoms, sonographic features, FNA results, and final surgical pathology. For comparison, we analyzed nodules <3 cm from this cohort also with benign FNA cytology. A total of 323 nodules with benign preoperative cytology were identified. Eighty-three nodules were <3 cm, 94 nodules were 3-3.9 cm, and 146 nodules were ≥4 cm in size. The false-negative rate was 11.7 % for all nodules ≥3 cm and 4.8 % for nodules <3 cm (p = 0.03). Subgroup analysis of nodules ≥3 cm revealed a false-negative rate of 12.8 % for nodules 3-3.9 cm and 11 % for nodules ≥4 cm. Age ≥55 years and asymptomatic clinical status were the only patient characteristics that reached statistical significance as risk factors. Final pathology of the false-negative specimens consisted mainly of follicular variant of papillary thyroid cancer and follicular thyroid cancer. When referred for thyroidectomy, patients with large thyroid nodules demonstrate a modest, yet significant, false-negative rate despite initial benign aspiration cytology. Therefore, thyroid nodules ≥3 cm may be considered for removal even when referred with benign preoperative cytology.
Clinical Features of Children With Autism Who Passed 18-Month Screening.
Øien, Roald A; Schjølberg, Synnve; Volkmar, Fred R; Shic, Frederick; Cicchetti, Domenic V; Nordahl-Hansen, Anders; Stenberg, Nina; Hornig, Mady; Havdahl, Alexandra; Øyen, Anne-Siri; Ventola, Pamela; Susser, Ezra S; Eisemann, Martin R; Chawarska, Katarzyna
2018-06-01
We compared sex-stratified developmental and temperamental profiles at 18 months in children screening negative for autism spectrum disorder (ASD) on the Modified Checklist for Autism in Toddlers (M-CHAT) but later receiving diagnoses of ASD (false-negative group) versus those without later ASD diagnoses (true-negative group). We included 68 197 screen-negative cases from the Norwegian Mother and Child Cohort Study (49.1% girls). Children were screened by using the 6 critical items of the M-CHAT at 18 months. Groups were compared on domains of the Ages and Stages Questionnaire and the Emotionality Activity Sociability Temperament Survey. Despite passing M-CHAT screening at 18 months, children in the false-negative group exhibited delays in social, communication, and motor skills compared with the true-negative group. Differences were more pronounced in girls. However, with regard to shyness, boys in the false-negative group were rated as more shy than their true-negative counterparts, but girls in the false-negative group were rated as less shy than their counterparts in the true-negative group. This is the first study to reveal that children who pass M-CHAT screening at 18 months and are later diagnosed with ASD exhibit delays in core social and communication areas as well as fine motor skills at 18 months. Differences appeared to be more pronounced in girls. With these findings, we underscore the need to enhance the understanding of early markers of ASD in boys and girls, as well as factors affecting parental report on early delays and abnormalities, to improve the sensitivity of screening instruments. Copyright © 2018 by the American Academy of Pediatrics.
Rui, Y; Han, M; Zhou, W; He, Q; Li, H; Li, P; Zhang, F; Shi, Y; Su, X
2018-06-06
To determine true negatives and characterise the variables associated with false-negative results when interpreting non-malignant results of computed tomography (CT)-guided lung biopsy. Nine hundred and fifty patients with initial non-malignant findings on their first transthoracic CT-guided core-needle biopsy (TTNB) were included in the study. Initial biopsy results were compared to definitive diagnoses established later. The negative predictive value (NPV) of non-malignant diseases upon initial TTNB was 83.6%. When the biopsy results indicated specific infection or benign tumour (n=225, 26.1%), they all were confirmed true negative for malignancy later. Only one inconclusive "granuloma" diagnosis was false negative. All 141 patients (141/861, 16.4%) who were false negative for malignancy were from the "infection not otherwise specified (NOS)", "inflammatory diseases", or "inconclusive" groups. Age (p=0.002), cancer history (p<0.001), target size (p=0.003), and pneumothorax during lung biopsy (p=0.003) were found to be significant predictors of false-negative results; 47.6% (410/861) of patients underwent additional invasive examinations to reach a final diagnosis. Ultimately, 52.7% (216/410) were successfully diagnosed. Specific infection, benign tumour, and granulomatous inflammation of first TTNBs were mostly true negative. Older age, history of cancer, larger target size, and pneumothorax were highly predictive of false-negative results for malignancies. In such cases, additional invasive examinations were frequently necessary to obtain final diagnoses. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Greyson, Bruce
2005-01-01
Some persons who claim to have had near-death experiences (NDEs) fail research criteria for having had NDEs ("false positives"); others who deny having had NDEs do meet research criteria for having had NDEs ("false negatives"). The author evaluated false positive claims and false negative denials in an organization that promotes near-death…
Fairfield, Beth; Mammarella, Nicola; Di Domenico, Alberto; D'Aurora, Marco; Stuppia, Liborio; Gatta, Valentina
2017-08-30
False memories are common memory distortions in everyday life and seem to increase with affectively connoted complex information. In line with recent studies showing a significant interaction between the noradrenergic system and emotional memory, we investigated whether healthy volunteer carriers of the deletion variant of the ADRA2B gene that codes for the α2b-adrenergic receptor are more prone to false memories than non-carriers. In this study, we collected genotype data from 212 healthy female volunteers; 91 ADRA2B carriers and 121 non-carriers. To assess gene effects on false memories for affective information, factorial mixed model analysis of variances (ANOVAs) were conducted with genotype as the between-subjects factor and type of memory error as the within-subjects factor. We found that although carriers and non-carriers made comparable numbers of false memory errors, they showed differences in the direction of valence biases, especially for inferential causal errors. Specifically, carriers produced fewer causal false memory errors for scripts with a negative outcome, whereas non-carriers showed a more general emotional effect and made fewer causal errors with both positive and negative outcomes. These findings suggest that putatively higher levels of noradrenaline in deletion carriers may enhance short-term consolidation of negative information and lead to fewer memory distortions when facing negative events. Copyright © 2017 Elsevier B.V. All rights reserved.
Nemoto, Kenji; Oh-ishi, Shuji; Taguchi, Masato; Hyodo, Kentaro; Kanazawa, Jun; Miura, Yukiko; Takaku, Takio; Usui, Shingo; Hayashihara, Kenji; Saito, Takefumi
2016-04-01
T-SPOT.TB (T-SPOT), an interferon-gamma release assay, has shown promise as a diagnostic tool for active tuberculosis (TB), and its use is expanding. Addition of the T-Cell Xtend (TCX) reagent may allow delayed processing, and this characteristic is important for using this test in the field. However, limited data is available on the usefulness of T-SPOT with TCX as a field test for diagnosing active TB. To investigate the clinical utility of T-SPOT with TCX and the risk factors for a false-negative result in patients with active TB. A total of 57 patients with active TB who underwent the T-SPOT test with TCX prior to treatment were enrolled between May 2013 and May 2015. One patient with an indeterminate result for T-SPOT was excluded; therefore, the data of 56 patients were eventually included in the final analysis. The basic characteristics and clinical findings were compared between the true-positive and false-negative T-SPOT groups. Of the 56 patients, 40 (71.4%), 13 (23.2%), 3 (5.4%) had true-positive, false-negative, and borderline T-SPOT results, respectively. This study did not reveal any significant risk factors for a false-negative T-SPOT result. In this clinical study, the proportion of patients with a false-negative result for T-SPOT with TCX for active TB was higher than that reported previously. Therefore, careful interpretation of a negative result for T-SPOT with TCX is necessary, regardless of the patient's background.
Linguistic Determinants of the Difficulty of True-False Test Items
ERIC Educational Resources Information Center
Peterson, Candida C.; Peterson, James L.
1976-01-01
Adults read a prose passage and responded to passages based on it which were either true or false and were phrased either affirmatively or negatively. True negatives yielded most errors, followed in order by false negatives, true affirmatives, and false affirmatives. (Author/RC)
Johnson, Cheryl C; Fonner, Virginia; Sands, Anita; Ford, Nathan; Obermeyer, Carla Mahklouf; Tsui, Sharon; Wong, Vincent; Baggaley, Rachel
2017-08-29
In accordance with global testing and treatment targets, many countries are seeking ways to reach the "90-90-90" goals, starting with diagnosing 90% of all people with HIV. Quality HIV testing services are needed to enable people with HIV to be diagnosed and linked to treatment as early as possible. It is essential that opportunities to reach people with undiagnosed HIV are not missed, diagnoses are correct and HIV-negative individuals are not inadvertently initiated on life-long treatment. We conducted this systematic review to assess the magnitude of misdiagnosis and to describe poor HIV testing practices using rapid diagnostic tests. We systematically searched peer-reviewed articles, abstracts and grey literature published from 1 January 1990 to 19 April 2017. Studies were included if they used at least two rapid diagnostic tests and reported on HIV misdiagnosis, factors related to potential misdiagnosis or described quality issues and errors related to HIV testing. Sixty-four studies were included in this review. A small proportion of false positive (median 3.1%, interquartile range (IQR): 0.4-5.2%) and false negative (median: 0.4%, IQR: 0-3.9%) diagnoses were identified. Suboptimal testing strategies were the most common factor in studies reporting misdiagnoses, particularly false positive diagnoses due to using a "tiebreaker" test to resolve discrepant test results. A substantial proportion of false negative diagnoses were related to retesting among people on antiretroviral therapy. Conclusions HIV testing errors and poor practices, particularly those resulting in false positive or false negative diagnoses, do occur but are preventable. Efforts to accelerate HIV diagnosis and linkage to treatment should be complemented by efforts to improve the quality of HIV testing services and strengthen the quality management systems, particularly the use of validated testing algorithms and strategies, retesting people diagnosed with HIV before initiating treatment and providing clear messages to people with HIV on treatment on the risk of a "false negative" test result.
Studies regarding the mechanism of false negative urea breath tests with proton pump inhibitors.
Graham, David Y; Opekun, Antone R; Hammoud, Fadi; Yamaoka, Yoshio; Reddy, Rita; Osato, Michael S; El-Zimaity, Hala M T
2003-05-01
The mechanism of false negative urea breath tests (UBTs) results among proton pump inhibitor (PPI) users is unknown. We studied the time course of PPI-associated negative UBT, the relation to Helicobacter pylori density, and whether gastric acidification would prevent false negative UBT results. In the UBT experiment, H. pylori-infected volunteers received omeprazole 20 mg b.i.d. for 13.5 days. UBTs with citric acid were done before, after 6.5 days of PPI, and 1, 2, 4, 7, and 14 days after therapy. In the culture and histology experiment, after a wash-out of >5 months, nine of the original subjects were rechallenged with omeprazole for 6.5 days. Antral and corpus biopsies for histology and culture were done before and 1 day after PPI administration. Thirty subjects (mean age 42 yr) were enrolled. UBTs were significantly reduced on day 6.5 (p = 0.031); 10 subjects (33%) developed transient negative UBTs. The UBT recovered in all but one subject by the fourth day post-PPI and in all subjects by day 14. In the culture and histology experiment, upon PPI rechallenge, three of nine subjects (33%) had negative UBTs. H. pylori density, whether measured by culture or histology, decreased with PPI therapy; antral biopsies became histologically negative in five subjects and corpus biopsies in three subjects. PPI-induced negative UBT results were related to the anti-H. pylori effect of the PPI. Acidification of the stomach did not prevent false negative UBT results. Three days is likely the minimum delay from stopping PPI until one should perform a test for active infection. A delay of 14 days is preferred.
Misinformation, partial knowledge and guessing in true/false tests.
Burton, Richard F
2002-09-01
Examiners disagree on whether or not multiple choice and true/false tests should be negatively marked. Much of the debate has been clouded by neglect of the role of misinformation and by vagueness regarding both the specification of test types and "partial knowledge" in relation to guessing. Moreover, variations in risk-taking in the face of negative marking have too often been treated in absolute terms rather than in relation to the effect of guessing on test unreliability. This paper aims to clarify these points and to compare the ill-effects on test reliability of guessing and of variable risk-taking. Three published studies on medical students are examined. These compare responses in true/false tests obtained with both negative marking and number-right scoring. The studies yield data on misinformation and on the extent to which students may fail to benefit from distrusted partial knowledge when there is negative marking. A simple statistical model is used to compare variations in risk-taking with test unreliability due to blind guessing under number-right scoring conditions. Partial knowledge should be least problematic with independent true/false items. The effect on test reliability of blind guessing under number-right conditions is generally greater than that due to the over-cautiousness of some students when there is negative marking.
Kim, Sue Jung; Kim, Yoonjung; Shin, Saeam; Song, Jaewoo; Choi, Jong Rak
2012-11-01
In the clinical laboratory, it is important both to reduce the number of peripheral blood slide reviews to save time and money and to avoid reporting false results. To determine differences in the slide review rates of 3 widely used automated hematologic analyzers, the Unicel DxH 800 (Beckman Coulter Inc, Fullerton, California), ADVIA 2120i (Siemens Diagnostics, Tarrytown, New York), and XE 2100 (Sysmex, Kobe, Japan), using International Consensus Group for Hematology Review guidelines. A total of 1485 samples were tested, and 300 were manually reviewed. Slide review rates, sensitivity, specificity, and false-positive and false-negative rates were estimated using consensus group rules and compared using χ(2) tests, Fisher exact tests, or generalized estimating equations. Unicel DxH 800, ADVIA 2120i, and XE 2100 showed 22.8%, 20.2%, and 28.6% slide review rates; 14.3%, 14.3%, and 9.7% false-negative rates; and 13.7, 11.3%, and 17.3% false-positive rates, respectively. All analyzers showed significantly higher false-negative rates than that of the consensus group (2.9%). False-negative rates were higher than the recommended levels. Among 3 automated hematologic analyzers, XE 2100 showed the highest rate of slide review. Because the present study clearly shows that the slide review rates have distinct characteristics among the studied analyzers, each individual laboratory should consider selecting the most appropriate analyzer according to clinical characteristics. Analyzers with high sensitivity may be advantageous in outpatient settings for screening patients, whereas analyzers with high specificity may be beneficial in inpatient settings for efficient patient care.
Mehler, W Tyler; Keough, Michael J; Pettigrove, Vincent
2018-04-01
Three common false-negative scenarios have been encountered with amendment addition in whole-sediment toxicity identification evaluations (TIEs): dilution of toxicity by amendment addition (i.e., not toxic enough), not enough amendment present to reduce toxicity (i.e., too toxic), and the amendment itself elicits a toxic response (i.e., secondary amendment effect). One such amendment in which all 3 types of false-negatives have been observed is with the nonpolar organic amendment (activated carbon or powdered coconut charcoal). The objective of the present study was to reduce the likelihood of encountering false-negatives with this amendment and to increase the value of the whole-sediment TIE bioassay. To do this, the present study evaluated the effects of various activated carbon additions to survival, growth, emergence, and mean development rate of Chironomus tepperi. Using this information, an alternative method for this amendment was developed which utilized a combination of multiple amendment addition ratios based on wet weight (1%, lower likelihood of the secondary amendment effect; 5%, higher reduction of contaminant) and nonconventional endpoints (emergence, mean development rate). This alternative method was then validated in the laboratory (using spiked sediments) and with contaminated field sediments. Using these multiple activated carbon ratios in combination with additional endpoints (namely, emergence) reduced the likelihood of all 3 types of false-negatives and provided a more sensitive evaluation of risk. Environ Toxicol Chem 2018;37:1219-1230. © 2017 SETAC. © 2017 SETAC.
Working memory affects false memory production for emotional events.
Mirandola, Chiara; Toffalini, Enrico; Ciriello, Alfonso; Cornoldi, Cesare
2017-01-01
Whereas a link between working memory (WM) and memory distortions has been demonstrated, its influence on emotional false memories is unclear. In two experiments, a verbal WM task and a false memory paradigm for negative, positive or neutral events were employed. In Experiment 1, we investigated individual differences in verbal WM and found that the interaction between valence and WM predicted false recognition, with negative and positive material protecting high WM individuals against false remembering; the beneficial effect of negative material disappeared in low WM participants. In Experiment 2, we lowered the WM capacity of half of the participants with a double task request, which led to an overall increase in false memories; furthermore, consistent with Experiment 1, the increase in negative false memories was larger than that of neutral or positive ones. It is concluded that WM plays a critical role in determining false memory production, specifically influencing the processing of negative material.
Xu, Stanley; Newcomer, Sophia; Nelson, Jennifer; Qian, Lei; McClure, David; Pan, Yi; Zeng, Chan; Glanz, Jason
2014-05-01
The Vaccine Safety Datalink project captures electronic health record data including vaccinations and medically attended adverse events on 8.8 million enrollees annually from participating managed care organizations in the United States. While the automated vaccination data are generally of high quality, a presumptive adverse event based on diagnosis codes in automated health care data may not be true (misclassification). Consequently, analyses using automated health care data can generate false positive results, where an association between the vaccine and outcome is incorrectly identified, as well as false negative findings, where a true association or signal is missed. We developed novel conditional Poisson regression models and fixed effects models that accommodate misclassification of adverse event outcome for self-controlled case series design. We conducted simulation studies to evaluate their performance in signal detection in vaccine safety hypotheses generating (screening) studies. We also reanalyzed four previously identified signals in a recent vaccine safety study using the newly proposed models. Our simulation studies demonstrated that (i) outcome misclassification resulted in both false positive and false negative signals in screening studies; (ii) the newly proposed models reduced both the rates of false positive and false negative signals. In reanalyses of four previously identified signals using the novel statistical models, the incidence rate ratio estimates and statistical significances were similar to those using conventional models and including only medical record review confirmed cases. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Underpowered samples, false negatives, and unconscious learning.
Vadillo, Miguel A; Konstantinidis, Emmanouil; Shanks, David R
2016-02-01
The scientific community has witnessed growing concern about the high rate of false positives and unreliable results within the psychological literature, but the harmful impact of false negatives has been largely ignored. False negatives are particularly concerning in research areas where demonstrating the absence of an effect is crucial, such as studies of unconscious or implicit processing. Research on implicit processes seeks evidence of above-chance performance on some implicit behavioral measure at the same time as chance-level performance (that is, a null result) on an explicit measure of awareness. A systematic review of 73 studies of contextual cuing, a popular implicit learning paradigm, involving 181 statistical analyses of awareness tests, reveals how underpowered studies can lead to failure to reject a false null hypothesis. Among the studies that reported sufficient information, the meta-analytic effect size across awareness tests was d z = 0.31 (95 % CI 0.24-0.37), showing that participants' learning in these experiments was conscious. The unusually large number of positive results in this literature cannot be explained by selective publication. Instead, our analyses demonstrate that these tests are typically insensitive and underpowered to detect medium to small, but true, effects in awareness tests. These findings challenge a widespread and theoretically important claim about the extent of unconscious human cognition.
Dividing Attention Lowers Children's but Increases Adults' False Memories
ERIC Educational Resources Information Center
Otgaar, Henry; Peters, Maarten; Howe, Mark L.
2012-01-01
The present study examined the impact of divided attention on children's and adults' neutral and negative true and false memories in a standard Deese/Roediger-McDermott paradigm. Children (7- and 11-year-olds; n = 126) and adults (n = 52) received 5 neutral and 5 negative Deese/Roediger-McDermott word lists; half of each group also received a…
Ahmed, Ayesha; Ahmed, Sajjad
2004-01-01
The objectives of this study were to compare bronchoalveolar lavage (BAL) cytology and transbronchial biopsy in the diagnosis of carcinoma lung and to determine accuracy of BAL cytology using histopathlologic examination of transbronchial biopsy as gold standard at our center. This study was carried out at Department of Histopathology, Ayub Medical College, Abbottabad, from 1.09.2000 to 28.02.2003. BAL fluid and bronchial biopsy were received and processed simultaneously. Four cytology and a set of histopathology slides were prepared. These were screened and diagnosis recorded. Sensitivity, Specificity, False Positive, False Negative, Positive predictive value and Negative predictive value of BAL cytology were determined using histopathology of transbronchial biopsy as gold standard. We found the sensitivity of BAL cytology to be 93.44% as compared with transbronchial biopsy. The specificity was 100%. There was no false positive while false negative results were 6.55 %. The positive predictive value was 100 %, while the negative predictive value was 75 %. The overall diagnostic efficacy of BAL cytology was 94.52 %. BAL cytology is a highly sensitive and specific test for diagnosis of carcinoma lung. It can be used as a quick and reliable diagnostic method for diagnosis of lung malignancy.
Vijayakumar, Vani; Boerner, Philip S; Jani, Ashesh B; Vijayakumar, Srinivasan
2005-05-01
Radionuclide sentinel lymph node localization and biopsy is a staging procedure that is being increasingly used to evaluate patients with invasive breast cancer who have clinically normal axillary nodes. The most important prognostic indicator in patients with invasive breast cancer is the axillary node status, which must also be known for correct staging, and influences the selection of adjuvant therapies. The accuracy of sentinel lymph node localization depends on a number of factors, including the injection method, the operating surgeon's experience and the hospital setting. The efficacy of sentinel lymph node mapping can be determined by two measures: the sentinel lymph node identification rate and the false-negative rate. Of these, the false-negative rate is the most important, based on a review of 92 studies. As sentinel lymph node procedures vary widely, nuclear medicine physicians and radiologists must be acquainted with the advantages and disadvantages of the various techniques. In this review, the factors that influence the success of different techniques are examined, and studies which have investigated false-negative rates and/or sentinel lymph node identification rates are summarized.
Storbeck, Justin
2013-01-01
I investigated whether negative affective states enhance encoding of and memory for item-specific information reducing false memories. Positive, negative, and neutral moods were induced, and participants then completed a Deese-Roediger-McDermott (DRM) false-memory task. List items were presented in unique spatial locations or unique fonts to serve as measures for item-specific encoding. The negative mood conditions had more accurate memories for item-specific information, and they also had fewer false memories. The final experiment used a manipulation that drew attention to distinctive information, which aided learning for DRM words, but also promoted item-specific encoding. For the condition that promoted item-specific encoding, false memories were reduced for positive and neutral mood conditions to a rate similar to that of the negative mood condition. These experiments demonstrated that negative affective cues promote item-specific processing reducing false memories. People in positive and negative moods encode events differently creating different memories for the same event.
Sizikova, T E; Lebedev, V N; Pantyukhov, V B; Borisevich, S V; Merkulov, V A
2015-01-01
Experience of study and possible ways of elimination of false positive and false negative results during execution of polymerase chain reaction on an example of Junin virus RNA detection. MATERIALSS AND METHODS: Junin virus--causative agent of Argentine hemorrhagic fever (AHF) strain XJpR37/5787 was obtained from the State collection of pathogenicity group I causative agents of the 48th Central Research Institute. Reagent kit for detection of Junin virus RNA by RT-PCR was developed in the Institute and consists of 4 sets: for isolation of RNA, execution of reverse-transcription reaction, execution of PCR and electrophoretic detection of PCR products. RT-PCR was carried out by a standard technique. Continuous cell cultures of African green monkey Vero B, GMK-AH-1(D) were obtained from the museum of cell culture department of the Centre. An experimental study of the effect of various factors of impact on the sample under investigation ("thawing-freezing", presence of formaldehyde, heparin) on the obtaining of false negative results during Junin virus RNA detection by using RT-PCR was studied. Addition of 0.01% heparin to the samples was shown to completely inhibit PCR. Addition of 0.05% formaldehyde significantly reduces sensitivity of the method. A possibility of reduction of analysis timeframe from 15 to 5 days was shown during detection of the causative agent in samples with low concentration of the latter by growing the samples and subsequent analysis of the material obtained by using RT-PCR. During detection of causative agent by using RT-PCR false negative results could appear in the presence of formaldehyde and heparin in the sample. A possibility of elimination of false negative PCR results due to concentration of the causative agent in the sample under investigation at a level below sensitivity threshold was shown on the example of Junin virus RNA detection by using growing of the pathogen in appropriate accumulation system with subsequent analysis of the material obtained using PCR.
Sievert, Lynnette L.; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E.
2010-01-01
Objective To test for a diurnal pattern in hot flashes in a multi-ethnic population living in a hot, humid environment. To examine rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Methods Study participants aged 45–55 were recruited from the general population of Hilo, Hawaii. Women wore a Biolog hot flash monitor, kept a diary for 24-hours, and also participated in 3-hour laboratory measures (n=199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true positive readings. Subjective hot flashes were considered the standard for computing false positive and false negative readings. True positive, false positive, and false negative readings were compared across ethnic groups by chi-square analyses. Results Frequencies of sternal, nuchal and subjective hot flashes peaked at 15:00 ± 1 hour with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true positive measures, but non-sternal electrodes picked up more false positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true positive or false positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false negative measures). Conclusions The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo was similar to results from more temperate environments. Lack of variation in sternal vs. non-sternal measures, and in true positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns. PMID:20220538
False Positive and False Negative Effects on Network Attacks
NASA Astrophysics Data System (ADS)
Shang, Yilun
2018-01-01
Robustness against attacks serves as evidence for complex network structures and failure mechanisms that lie behind them. Most often, due to detection capability limitation or good disguises, attacks on networks are subject to false positives and false negatives, meaning that functional nodes may be falsely regarded as compromised by the attacker and vice versa. In this work, we initiate a study of false positive/negative effects on network robustness against three fundamental types of attack strategies, namely, random attacks (RA), localized attacks (LA), and targeted attack (TA). By developing a general mathematical framework based upon the percolation model, we investigate analytically and by numerical simulations of attack robustness with false positive/negative rate (FPR/FNR) on three benchmark models including Erdős-Rényi (ER) networks, random regular (RR) networks, and scale-free (SF) networks. We show that ER networks are equivalently robust against RA and LA only when FPR equals zero or the initial network is intact. We find several interesting crossovers in RR and SF networks when FPR is taken into consideration. By defining the cost of attack, we observe diminishing marginal attack efficiency for RA, LA, and TA. Our finding highlights the potential risk of underestimating or ignoring FPR in understanding attack robustness. The results may provide insights into ways of enhancing robustness of network architecture and improve the level of protection of critical infrastructures.
Positive events protect children from causal false memories for scripted events.
Melinder, Annika; Toffalini, Enrico; Geccherle, Eleonora; Cornoldi, Cesare
2017-11-01
Adults produce fewer inferential false memories for scripted events when their conclusions are emotionally charged than when they are neutral, but it is not clear whether the same effect is also found in children. In the present study, we examined this issue in a sample of 132 children aged 6-12 years (mean 9 years, 3 months). Participants encoded photographs depicting six script-like events that had a positively, negatively, or a neutral valenced ending. Subsequently, true and false recognition memory of photographs related to the observed scripts was tested as a function of emotionality. Causal errors-a type of false memory thought to stem from inferential processes-were found to be affected by valence: children made fewer causal errors for positive than for neutral or negative events. Hypotheses are proposed on why adults were found protected against inferential false memories not only by positive (as for children) but also by negative endings when administered similar versions of the same paradigm.
Accuracy and reliability of forensic latent fingerprint decisions
Ulery, Bradford T.; Hicklin, R. Austin; Buscaglia, JoAnn; Roberts, Maria Antonia
2011-01-01
The interpretation of forensic fingerprint evidence relies on the expertise of latent print examiners. The National Research Council of the National Academies and the legal and forensic sciences communities have called for research to measure the accuracy and reliability of latent print examiners’ decisions, a challenging and complex problem in need of systematic analysis. Our research is focused on the development of empirical approaches to studying this problem. Here, we report on the first large-scale study of the accuracy and reliability of latent print examiners’ decisions, in which 169 latent print examiners each compared approximately 100 pairs of latent and exemplar fingerprints from a pool of 744 pairs. The fingerprints were selected to include a range of attributes and quality encountered in forensic casework, and to be comparable to searches of an automated fingerprint identification system containing more than 58 million subjects. This study evaluated examiners on key decision points in the fingerprint examination process; procedures used operationally include additional safeguards designed to minimize errors. Five examiners made false positive errors for an overall false positive rate of 0.1%. Eighty-five percent of examiners made at least one false negative error for an overall false negative rate of 7.5%. Independent examination of the same comparisons by different participants (analogous to blind verification) was found to detect all false positive errors and the majority of false negative errors in this study. Examiners frequently differed on whether fingerprints were suitable for reaching a conclusion. PMID:21518906
Accuracy and reliability of forensic latent fingerprint decisions.
Ulery, Bradford T; Hicklin, R Austin; Buscaglia, Joann; Roberts, Maria Antonia
2011-05-10
The interpretation of forensic fingerprint evidence relies on the expertise of latent print examiners. The National Research Council of the National Academies and the legal and forensic sciences communities have called for research to measure the accuracy and reliability of latent print examiners' decisions, a challenging and complex problem in need of systematic analysis. Our research is focused on the development of empirical approaches to studying this problem. Here, we report on the first large-scale study of the accuracy and reliability of latent print examiners' decisions, in which 169 latent print examiners each compared approximately 100 pairs of latent and exemplar fingerprints from a pool of 744 pairs. The fingerprints were selected to include a range of attributes and quality encountered in forensic casework, and to be comparable to searches of an automated fingerprint identification system containing more than 58 million subjects. This study evaluated examiners on key decision points in the fingerprint examination process; procedures used operationally include additional safeguards designed to minimize errors. Five examiners made false positive errors for an overall false positive rate of 0.1%. Eighty-five percent of examiners made at least one false negative error for an overall false negative rate of 7.5%. Independent examination of the same comparisons by different participants (analogous to blind verification) was found to detect all false positive errors and the majority of false negative errors in this study. Examiners frequently differed on whether fingerprints were suitable for reaching a conclusion.
Ibañez-Sanz, Gemma; Garcia, Montse; Milà, Núria; Rodríguez-Moranta, Francisco; Binefa, Gemma; Gómez-Matas, Javier; Benito, Llúcia; Padrol, Isabel; Barenys, Mercè; Moreno, Victor
2017-09-01
The aim of this study was to analyse false-negative (FN) results of the faecal immunochemical test (FIT) and its determinants in a colorectal cancer screening programme in Catalonia. We carried out a cross-sectional study among 218 screenees with a negative FIT result who agreed to undergo a colonoscopy. A false-negative result was defined as the detection, at colonoscopy, of intermediate/high-risk polyps or colorectal cancer in a patient with a previous negative FIT (<20 µgHb/g). Multivariate logistic regression models were constructed to identify sociodemographic (sex, age) and screening variables (quantitative faecal haemoglobin, colonoscopy findings) related to FN results. Adjusted odds ratios and their 95% confidence intervals were estimated. There were 15.6% FN FIT results. Faecal haemoglobin was undetected in 45.5% of these results and was below 4 µgHb/g in 94.0% of the individuals with a FN result. About 60% of the lesions were located in the proximal colon, whereas the expected percentage was 30%. Decreasing the positivity threshold of FIT does not increase the detection rate of advanced neoplasia, but may increase the costs and potential adverse effects.
Reducing false negatives in clinical practice: the role of neural network technology.
Mango, L J
1996-10-01
The fact that some cervical smears result in false-negative findings is an unavoidable and unpredictable consequence of the conventional (manual microscopic) method of screening. Errors in the detection and interpretation of abnormality are cited as leading causes of false-negative cytology findings; these are random errors that are not known to correlate with any patient risk factor, which makes the false-negative findings a "silent" threat that is difficult to prevent. Described by many as a labor-intensive procedure, the microscopic evaluation of a cervical smear involves a detailed search among hundreds of thousands of cells on each smear for a possible few that may indicate abnormality. Investigations into causes of false-negative findings preceding the discovery of high-grade lesions found that many smears had very few diagnostic cells that were often very small in size. These small cells were initially overlooked or misinterpreted and repeatedly missed on rescreening. PAPNET testing is designed to supplement conventional screening by detecting abnormal cells that initially may have been missed by microscopic examination. This interactive system uses neural networks, a type of artificial intelligence well suited for pattern recognition, to automate the arduous search for abnormality. The instrument focuses the review of suspicious cells by a trained cytologist. Clinical studies indicate that PAPNET testing is sensitive to abnormality typically missed by conventional screening and that its use as a supplemental test improves the accuracy of screening.
Half, Elizabeth E; Mlynarsky, Liat; Naftali, Timna; Benjaminov, Fabiana; Konikoff, Fred M
2013-09-01
Fecal Occult Blood Test (FOBT) is an accepted screening test for colorectal cancer (CRC). It has been shown to decrease mortality by up to 30%. The outcome of screening failures has not been adequately studied. The purpose of this study was to assess the outcome of patients who were diagnosed with CRC after a false negative FOBT. We identified all consecutive CRCs from pathology reports between 2005 and 2010. Patients were divided according to their FOBT result. Those who became positive were compared to patients who remained negative. Altogether 401 CRCs were identified. Of those, 202 never performed a FOBT. At least one negative FOBT was performed by 133 individuals (67%). Of these, 76 remained negative (false negatives, FN) and 57 became positive (positive conversion, PC, controls). The prevalence of metastatic disease was threefold higher among the FNs as compared to the PC group (16 [22.2%] vs. 4 [7.5%], P=0.022). All-cause mortality was also significantly higher among FNs versus PCs (24 [31.6%] vs. 5 [8.8%], P=0.001); in Cox regression analysis of survival (covariates: FNs vs. PC, gender, age, medications and co-morbidities) FNs had increased mortality compared to the PC (HR 2.929, P=0.033, CI 95% 1.092-7.858). No statistically significant difference was found regarding all primary end points when comparing the FN and the "No test" group. These data disclose a particular risk of FOBT as a screening test. A subgroup of patients with "false" negative tests may have increased morbidity and mortality. Efforts should be made to recognize and characterize this high-risk group.
Wang, Zhishi; Craven, Mark; Newton, Michael A.; Ahlquist, Paul
2013-01-01
Systematic, genome-wide RNA interference (RNAi) analysis is a powerful approach to identify gene functions that support or modulate selected biological processes. An emerging challenge shared with some other genome-wide approaches is that independent RNAi studies often show limited agreement in their lists of implicated genes. To better understand this, we analyzed four genome-wide RNAi studies that identified host genes involved in influenza virus replication. These studies collectively identified and validated the roles of 614 cell genes, but pair-wise overlap among the four gene lists was only 3% to 15% (average 6.7%). However, a number of functional categories were overrepresented in multiple studies. The pair-wise overlap of these enriched-category lists was high, ∼19%, implying more agreement among studies than apparent at the gene level. Probing this further, we found that the gene lists implicated by independent studies were highly connected in interacting networks by independent functional measures such as protein-protein interactions, at rates significantly higher than predicted by chance. We also developed a general, model-based approach to gauge the effects of false-positive and false-negative factors and to estimate, from a limited number of studies, the total number of genes involved in a process. For influenza virus replication, this novel statistical approach estimates the total number of cell genes involved to be ∼2,800. This and multiple other aspects of our experimental and computational results imply that, when following good quality control practices, the low overlap between studies is primarily due to false negatives rather than false-positive gene identifications. These results and methods have implications for and applications to multiple forms of genome-wide analysis. PMID:24068911
Valence and the development of immediate and long-term false memory illusions.
Howe, Mark L; Candel, Ingrid; Otgaar, Henry; Malone, Catherine; Wimmer, Marina C
2010-01-01
Across five experiments we examined the role of valence in children's and adults' true and false memories. Using the Deese/Roediger-McDermott paradigm and either neutral or negative-emotional lists, both adults' (Experiment 1) and children's (Experiment 2) true recall and recognition was better for neutral than negative items, and although false recall was also higher for neutral items, false recognition was higher for negative items. The last three experiments examined adults' (Experiment 3) and children's (Experiments 4 and 5) 1-week long-term recognition of neutral and negative-emotional information. The results replicated the immediate recall and recognition findings from the first two experiments. More important, these experiments showed that although true recognition decreased over the 1-week interval, false recognition of neutral items remained unchanged whereas false recognition of negative-emotional items increased. These findings are discussed in terms of theories of emotion and memory as well as their forensic implications.
Nieuwland, Mante S; Kuperberg, Gina R
2008-12-01
Our brains rapidly map incoming language onto what we hold to be true. Yet there are claims that such integration and verification processes are delayed in sentences containing negation words like not. However, studies have often confounded whether a statement is true and whether it is a natural thing to say during normal communication. In an event-related potential (ERP) experiment, we aimed to disentangle effects of truth value and pragmatic licensing on the comprehension of affirmative and negated real-world statements. As in affirmative sentences, false words elicited a larger N400 ERP than did true words in pragmatically licensed negated sentences (e.g., "In moderation, drinking red wine isn't bad/good..."), whereas true and false words elicited similar responses in unlicensed negated sentences (e.g., "A baby bunny's fur isn't very hard/soft..."). These results suggest that negation poses no principled obstacle for readers to immediately relate incoming words to what they hold to be true.
Palmier, James; Lanzrath, Brian; Dixon, Ammon; Idowu, Oluseun
2014-01-01
To identify and quantify demographic correlates of false-negative self-reporting of tobacco use in life insurance applicants. Several studies have assessed the sensitivity of self-reporting for tobacco use in various populations, but statistical examination of the causes of misreporting has been rarer. The very large (488,000 confirmed tobacco users) sample size, US-wide geographic scope, and unique incentive structure of the life insurance application process permit more robust and insurance industry-specific results in this study. Approximately 6.2 million life insurance applicants for whom both tobacco-use interview questions and a confirmatory urine cotinine test were completed between 1999 and 2012 were evaluated for consistency between self-reported and laboratory-confirmed tobacco-use status. The data set was subjected to logistic regression to identify predictors of false negative self-reports (FNSR). False-negative self-reporting was found to be strongly associated with male gender, applicant ages of less than 30 or greater than 60, and low cotinine positivity rates in the applicant's state of residence. Policy face value was also moderately predictive, values above $500,000 associated with moderately higher FNSR. The findings imply that FNSR in life insurance applicants may be the result of complex interactions among financial incentives, geography and presumptive peer groups, and gender.
Martínez-Pacheco, María C; Ferrán de la Cierva, Luis; García-Purriños, Francisco J
Despite its importance, the existence of false negatives (patients who are told they hear well, but they have some degree of hipacusia) is rarely evaluated in programs for early detection of hearing loss. The aim of this study is to determine the variables that can lead to a delayed diagnosis, especially the existence of false negatives and the lack of registration of risk factors. A retrospective study of prevalence has been carried out, in which the medical records of children diagnosed with sensorineural hearing loss born within 2005 and 2012 in the health centers of study have been analyzed. Of the 32 children with sensorineural hearing loss, 16 passed the OAE, 12 did not passed the OAE, and in four they were not carried out. Of the children who passed the OAE, 57% have severe hearing loss. 66% of children with hearing loss presented a risk factor for hearing loss at birth, being the most frecuent family history of hearing loss, but only 7% of those with family history of hearing loss were included in the risk group. The results of the study indicate that the late diagnosis of hearing loss is related to the presence of false negatives to the OAE and the non-registration of risk factors. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.
Proksch, A L; Unterer, S; Speck, S; Truyen, U; Hartmann, K
2015-06-01
False negative faecal canine parvovirus (CPV) antigen ELISA results in dogs with CPV infection are common, but the factors that lead to these false negative results are still unknown. The aim of this study was to investigate whether dogs with a false negative faecal CPV antigen ELISA result have milder clinical signs and laboratory changes, a lower faecal virus load, higher faecal and serum CPV antibody titres and a faster recovery than dogs with a positive result. Eighty dogs with CPV infection, confirmed by the presence of clinical signs and a positive faecal CPV polymerase chain reaction (PCR), were assigned to two groups according to their faecal antigen ELISA result. Time until presentation, severity of symptoms, laboratory parameters, faecal virus load, faecal and serum antibody titres, and CPV sequencing data were compared between both groups. In 38/80 dogs that were hospitalised until recovery, the time to recovery, mortality, and the course of the disease were compared between dogs with positive and negative faecal antigen ELISA results. Of the 80 dogs included, 41 (51.3%) had a false negative faecal antigen ELISA result. ELISA-negative dogs had a significantly shorter time until presentation, lower frequency of defaecation, lower faecal virus load, and higher serum antibody concentrations than ELISA-positive dogs. Laboratory changes, CPV shedding, and outcomes were not associated with faecal antigen ELISA results. In conclusion, low faecal CPV load and antibodies binding to CPV antigen in faeces are likely to be important reasons for false negative faecal antigen ELISA results. Dogs with clinical signs of CPV infection should be retested by faecal PCR. Copyright © 2015 Elsevier Ltd. All rights reserved.
Impact of false-negative sentinel lymph node biopsy on survival in patients with cutaneous melanoma.
Caracò, C; Marone, U; Celentano, E; Botti, G; Mozzillo, N
2007-09-01
Sentinel lymph node biopsy is widely accepted as standard care in melanoma despite lack of pertinent randomized trials results. A possible pitfall of this procedure is the inaccurate identification of the sentinel lymph node leading to biopsy and analysis of a nonsentinel node. Such a technical failure may yield a different prognosis. The purpose of this study is to analyze the incidence of false negativity and its impact on clinical outcome and to try to understand its causes. The Melanoma Data Base at National Cancer Institute of Naples was analyzed comparing results between false-negative and tumor-positive sentinel node patients focusing on overall survival and prognostic factors influencing the clinical outcome. One hundred fifty-one cases were diagnosed to be tumor-positive after sentinel lymph node biopsy and were subjected to complete lymph node dissection. Thirty-four (18.4%)patients with tumor-negative sentinel node subsequently developed lymph node metastases in the basin site of the sentinel procedure. With a median follow-up of 42.8 months the 5-year overall survival was 48.4% and 66.3% for false-negative and tumor-positive group respectively with significant statistical differences (P < .03). The sensitivity of sentinel lymph node biopsy was 81.6%, and a regional nodal basin recurrence after negative-sentinel node biopsy means a worse prognosis, compared with patients submitted to complete lymph node dissection after a positive sentinel biopsy. The evidence of higher number of tumor-positive nodes after delayed lymphadenectomy in false-negative group compared with tumor-positive sentinel node cases, confirmed the importance of an early staging of lymph nodal involvement. Further data will better clarify the role of prognostic factors to identify cases with a more aggressive biological behavior of the disease.
Quality control in molecular immunohistochemistry
2008-01-01
Immunoperoxidase histochemistry is a widespread method of assessing expression of biomolecules in tissue samples. Accurate assessment of the expression levels of genes is critical for the management of disease, particularly as therapy targeted to specific molecules becomes more widespread. Determining the quality of preservation of macromolecules in tissue is important to avoid false negative and false positive results. In this review we discuss (1) issues of sensitivity (false negativity) and specificity (false positivity) of immunohistochemical stains, (2) approaches to better understanding differences in immunostains done by different laboratories (including the recently proposed MISFISHIE specification for tissue localization studies), and (3) approaches to assessing the quality of preservation of macromolecules in tissue, particularly in small biopsy samples. PMID:18648842
Paige F.B. Ferguson; Michael J. Conroy; Jeffrey Hepinstall-Cymerman; Nigel Yoccoz
2015-01-01
False positive detections, such as species misidentifications, occur in ecological data, although many models do not account for them. Consequently, these models are expected to generate biased inference.The main challenge in an analysis of data with false positives is to distinguish false positive and false negative...
Wang, Jann-Yuan; Lee, Li-Na; Lai, Hsin-Chih; Hsu, Hsiao-Leng; Jan, I-Shiow; Yu, Chong-Jen; Hsueh, Po-Ren; Yang, Pan-Chyr
2007-12-01
Because of the increasing numbers of nontuberculous mycobacterial isolates from clinical specimens, rapid and accurate methods for culture confirmation of Mycobacterium tuberculosis are urgently needed. The study evaluated the performance of the Capilia TB immunochromatographic assay (TAUNS, Numazu, Japan) for culture confirmation of M. tuberculosis using 242 culture-positive liquid media in 2 mycobacterial laboratories from November 2005 to February 2006. Among the 242 samples, 183 were also tested with the BD ProbeTec ET (CTB) assay (Becton Dickinson, Sparks, MD). The results of both assays were compared to the culture results and to each other. The overall sensitivity and specificity of the Capilia TB assay were 98.6% and 97.9%, respectively, and for the CTB assay were 97.3% and 97.1%, respectively. The positive and negative predictive values for the Capilia TB assay were 98.6% and 97.9%, respectively, and for the CTB assay were 98.2% and 95.8%, respectively. Among the 183 samples tested with both assays, 8 had discrepant results, including Capilia-TB-false-positive in 2, CTB-false-positive in another 2, CTB-false-negative in 2, Capilia TB-false-negative in 1, and both assays with false-negative results in the remaining one. This study demonstrated that the Capilia TB assay has a similar diagnostic value with the CTB assay. In addition, with the immunochromatographic method, it is less time-consuming and does not require other laboratory equipment.
Galkin, O Yu; Besarab, A B; Lutsenko, T N
2017-01-01
The goal of this work was to study sensitivity and specificity of the developed ELISA set for the identification of IgG antibodies against Chlamydia trachomatis HSP-60 (using biotinylated tyramine-based signal amplification system). The study was conducted using a panel of characterized sera, as well as two reference ELISA sets of similar purpose. According to the results of ELISA informative value parameters, the ELISA we have developed showed the highest specificity and sensitivity parameters (no false negative or false positive results were registered). In 4 out of 15 intralaboratory panel serum samples initially identified as negative, anti-HSP-60 IgG-antibodies test result in reference ELISA sets upon dilution changed from negative to positive. The nature of titration curves of false negative sera and commercial monoclonal antibodies А57-В9 against C. trachomatis HSP-60 after incubation for 24 h was indicative of the presence of anti-idiotypic antibodies in these samples. Upon sera dilution, idiotypic-anti-idiotypic complexes dissociated, which caused the change of test result. High informative value of the developed ELISA set for identification of IgG antibodies against C. trachomatis HSP-60 has been proven. Anti-idiotypic antibodies possessing C. trachomatis anti-HSP-60 activity and being one of the causes of false negative results of the relevant ELISA-based tests have been identified in blood sera of individuals infected with chlamydial genitourinary infection agents.
Ventilation/perfusion single-photon emission computed tomography: a service evaluation.
Parekh, Amit; Graham, Richard; Redman, Stewart
2017-08-01
To identify the positive rate and negative predictive value (NPV) of our ventilation/perfusion (V/Q) single-photon emission computed tomography (SPECT) service as respective markers of overcalling (false positives) and undercalling (false negatives). We also identified the indeterminate rate as an indicator of the technical quality of the scans and reporter confidence. V/Q SPECT studies carried out over 5 years were classified into positive, negative and indeterminate results. Patients who had died or had pulmonary emboli on imaging within 3 months of a negative V/Q SPECT were identified as false negatives, from which the NPV was calculated. The total number of positive and indeterminate studies as a proportion of all studies was calculated as the positive and indeterminate rates. The positive rate, NPV and indeterminate rates in nonpregnant patients were 24, 98.7-100 and 3.6%, respectively. The positive rate, NPV and indeterminate rates in pregnant patients were 6.8, 100 and 2.3%, respectively. The positive rate and NPV for nonpregnant patients were similar to the published literature. This suggests that we provide a safe service. The indeterminate rate was slightly higher than the stated guidelines. The study shows that the positive rate and NPV are achievable indicators of potential overcalling and undercalling in a V/Q SPECT service.This is also one of the first studies to report a positive rate in pregnant patients undergoing V/Q SPECT that other institutions can use as a standard when evaluating their services.
Choi, Hae-Yoon; Kensinger, Elizabeth A; Rajaram, Suparna
2017-09-01
Social transmission of memory and its consequence on collective memory have generated enduring interdisciplinary interest because of their widespread significance in interpersonal, sociocultural, and political arenas. We tested the influence of 3 key factors-emotional salience of information, group structure, and information distribution-on mnemonic transmission, social contagion, and collective memory. Participants individually studied emotionally salient (negative or positive) and nonemotional (neutral) picture-word pairs that were completely shared, partially shared, or unshared within participant triads, and then completed 3 consecutive recalls in 1 of 3 conditions: individual-individual-individual (control), collaborative-collaborative (identical group; insular structure)-individual, and collaborative-collaborative (reconfigured group; diverse structure)-individual. Collaboration enhanced negative memories especially in insular group structure and especially for shared information, and promoted collective forgetting of positive memories. Diverse group structure reduced this negativity effect. Unequally distributed information led to social contagion that creates false memories; diverse structure propagated a greater variety of false memories whereas insular structure promoted confidence in false recognition and false collective memory. A simultaneous assessment of network structure, information distribution, and emotional valence breaks new ground to specify how network structure shapes the spread of negative memories and false memories, and the emergence of collective memory. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
How does negative emotion cause false memories?
Brainerd, C J; Stein, L M; Silveira, R A; Rohenkohl, G; Reyna, V F
2008-09-01
Remembering negative events can stimulate high levels of false memory, relative to remembering neutral events. In experiments in which the emotional valence of encoded materials was manipulated with their arousal levels controlled, valence produced a continuum of memory falsification. Falsification was highest for negative materials, intermediate for neutral materials, and lowest for positive materials. Conjoint-recognition analysis produced a simple process-level explanation: As one progresses from positive to neutral to negative valence, false memory increases because (a) the perceived meaning resemblance between false and true items increases and (b) subjects are less able to use verbatim memories of true items to suppress errors.
Taylor, Darlene; Durigon, Monica; Davis, Heather; Archibald, Chris; Konrad, Bernhard; Coombs, Daniel; Gilbert, Mark; Cook, Darrel; Krajden, Mel; Wong, Tom; Ogilvie, Gina
2015-03-01
Failure to understand the risk of false-negative HIV test results during the window period results in anxiety. Patients typically want accurate test results as soon as possible while clinicians prefer to wait until the probability of a false-negative is virtually nil. This review summarizes the median window periods for third-generation antibody and fourth-generation HIV tests and provides the probability of a false-negative result for various days post-exposure. Data were extracted from published seroconversion panels. A 10-day eclipse period was used to estimate days from infection to first detection of HIV RNA. Median (interquartile range) days to seroconversion were calculated and probabilities of a false-negative result at various time periods post-exposure are reported. The median (interquartile range) window period for third-generation tests was 22 days (19-25) and 18 days (16-24) for fourth-generation tests. The probability of a false-negative result is 0.01 at 80 days' post-exposure for third-generation tests and at 42 days for fourth-generation tests. The table of probabilities of falsely-negative HIV test results may be useful during pre- and post-test HIV counselling to inform co-decision making regarding the ideal time to test for HIV. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
False feedback and beliefs influence name recall in younger and older adults.
Strickland-Hughes, Carla M; West, Robin Lea; Smith, Kimberly A; Ebner, Natalie C
2017-09-01
Feedback is an important self-regulatory process that affects task effort and subsequent performance. Benefits of positive feedback for list recall have been explored in research on goals and feedback, but the effect of negative feedback on memory has rarely been studied. The current research extends knowledge of memory and feedback effects by investigating face-name association memory and by examining the potential mediation of feedback effects, in younger and older adults, through self-evaluative beliefs. Beliefs were assessed before and after name recognition and name recall testing. Repeated presentation of false positive feedback was compared to false negative feedback and a no feedback condition. Results showed that memory self-efficacy declined over time for participants in the negative and no feedback conditions but was sustained for those receiving positive feedback. Furthermore, participants who received negative feedback felt older after testing than before testing. For name recall, the positive feedback group outperformed the negative feedback and no feedback groups combined, with no age interactions. The observed feedback-related effects on memory were fully mediated by changes in memory self-efficacy. These findings advance our understanding of how beliefs are related to feedback in memory and inform future studies examining the importance of self-regulation in memory.
Lee, Grace J; Suhr, Julie A
2018-03-31
Expectancy is a psychological factor that can impact treatment effectiveness. Research on neurofeedback for attention-deficit/hyperactivity disorder (ADHD) suggests expectancy may contribute to treatment outcomes, though evidence for expectancy as an explanatory factor is sparse. This pilot study investigated the effects of expectancies on self-reported ADHD symptoms in simulated neurofeedback. Forty-six adults who were concerned that they had ADHD expected to receive active neurofeedback, but were randomly assigned to receive a placebo with false feedback indicating attentive (positive false feedback) or inattentive (negative false feedback) states. Effects of the expectancy manipulation were measured on an ADHD self-report scale. Large expectancy effects were found, such that individuals who received positive false feedback reported significant decreases in ADHD symptoms, whereas individuals who received negative false feedback reported significant increases in ADHD symptoms. Findings suggest that expectancy should be considered as an explanatory mechanism for ADHD symptom change in response to neurofeedback.
Aliyev, Shamil; Agcaoglu, Orhan; Aksoy, Erol; Birsen, Onur; Milas, Mira; Mitchell, Jamie; Siperstein, Allan; Berber, Eren
2014-11-01
Tc-99 sestamibi (MIBI) scan is the imaging study most frequently used in primary hyperparathyroidism (PHP). Transcutaneous cervical ultrasonography (US) is the other modality used for preoperative localization. The aim of this study was to determine whether surgeon-performed neck US can be used as the primary localizing study in PHP. This was a prospective study of 1,000 consecutive patients with first-time, sporadic PHP who underwent parathyroidectomy at a tertiary academic center. All patients had surgeon-performed neck US and MIBI before bilateral neck exploration. The findings at exploration were 72% single adenoma, 15% double adenoma, and 13% hyperplasia. When US suggested single-gland disease (n = 842), MIBI was concordant in 82.5%, discordant and false in 8%, negative in 7%, and discordant but correct in 2.5%. When US suggested multigland disease (n = 68), MIBI was concordant in 47%, discordant and false in 41%, and negative in 12%. When US was negative (n = 90), MIBI was positive and correct in 43%, negative in 31%, and positive but false in 26%. Surgeon-performed neck US identified unrecognized thyroid nodules in 326 patients (33%), which led to fine-needle aspiration biopsy in 161 (49%) patients and thyroid surgery in 103 (32%) patients, with a final diagnosis of thyroid cancer in 24 (7%) patients. Our results show that MIBI provides additional useful information in only a minority of patients with a positive US in PHP. Nevertheless, MIBI benefits about half of patients with a negative US. Because one-third of this patient population has unrecognized thyroid nodules as well, we propose that the most cost-effective algorithm would be to do US first and reserve MIBI for US-negative cases. Copyright © 2014 Elsevier Inc. All rights reserved.
Bonanzinga, Tommaso; Zahar, Akos; Dütsch, Michael; Lausmann, Christian; Kendoff, Daniel; Gehrke, Thorsten
2017-02-01
A key issue in the treatment of periprosthetic joint infection (PJI) is the correct diagnosis. The main problem is lack of diagnostic tools able to diagnose a PJI with high accuracy. Alpha-defensin has been proposed as a possible solution, but in the current literature, there is a lack of independent validation. We performed a prospective study to determine (1) what is the sensitivity, specificity, and positive and the negative predictive values of the alpha-defensin immunoassay test in diagnosing PJI; and (2) which clinical features may be responsible for false-positive and false-negative results? Preoperative aspiration was performed in all patients presenting with a painful hip/knee arthroplasty, including both primary and revision implants. Metallosis, other inflammatory comorbidities, and previous/concomitant antibiotic therapy were not considered as exclusion criteria. An inadequate amount of synovial fluid for culture was an exclusion criterion. A total of 156 patients (65 knees, 91 hips) were included in this prospective study. At the time of revision, synovial fluid samples were taken to perform the alpha-defensin assay. During surgical débridement of tissue, samples for cultures and histologic evaluation were taken, and samples were cultured until positive or until negative at 14 days. A diagnosis of PJI was confirmed in 29 patients according to the International Consensus Group on PJI. The sensitivity of the alpha-defensin immunoassay was 97% (95% confidence interval [CI], 92%-99%), the specificity was 97% (95% CI, 92%-99%), the positive predictive value was 88% (95% CI, 81%-92%), and the negative predictive value was 99% (95% CI, 96%-99%). Among four false-positive patients, two had metallosis and one had polyethylene wear. The false-negative case presented with a draining sinus, and intraoperative cultures were also negative. Alpha-defensin assay appears to be a reliable test, but followup evaluation is needed to estimate longer term performance of the test. The authors believe that alpha-defensin has demonstrated itself to be sufficiently robust that PJI diagnostic criteria now should include this test. Future studies are needed to compare the differences among the diagnostic capability of the available tests, in particular when metallosis is present, because metallosis may predispose the test to a false-positive result. Level I, diagnostic study.
Sentinel Lymph Node Detection Using Carbon Nanoparticles in Patients with Early Breast Cancer
Lu, Jianping; Zeng, Yi; Chen, Xia; Yan, Jun
2015-01-01
Purpose Carbon nanoparticles have a strong affinity for the lymphatic system. The purpose of this study was to evaluate the feasibility of sentinel lymph node biopsy using carbon nanoparticles in early breast cancer and to optimize the application procedure. Methods Firstly, we performed a pilot study to demonstrate the optimized condition using carbon nanoparticles for sentinel lymph nodes (SLNs) detection by investigating 36 clinically node negative breast cancer patients. In subsequent prospective study, 83 patients with clinically node negative breast cancer were included to evaluate SLNs using carbon nanoparticles. Another 83 SLNs were detected by using blue dye. SLNs detection parameters were compared between the methods. All patients irrespective of the SLNs status underwent axillary lymph node dissection for verification of axillary node status after the SLN biopsy. Results In pilot study, a 1 ml carbon nanoparticles suspension used 10–15min before surgery was associated with the best detection rate. In subsequent prospective study, with carbon nanoparticles, the identification rate, accuracy, false negative rate was 100%, 96.4%, 11.1%, respectively. The identification rate and accuracy were 88% and 95.5% with 15.8% of false negative rate using blue dye technique. The use of carbon nanoparticles suspension showed significantly superior results in identification rate (p = 0.001) and reduced false-negative results compared with blue dye technique. Conclusion Our study demonstrated feasibility and accuracy of using carbon nanoparticles for SLNs mapping in breast cancer patients. Carbon nanoparticles are useful in SLNs detection in institutions without access to radioisotope. PMID:26296136
Wu, Hu-bing; Wang, Lijuan; Wang, Quan-shi; Han, Yan-jian; Li, Hong-sheng; Zhou, Wen-lan; Tian, Ying
2015-01-01
Purpose. The present study investigated which type of adenocarcinoma with BAC features was prone to be false-negative on 18F-FDG PET/CT. Materials and Methods. A retrospective study was performed on 51 consecutive patients with localized adenocarcinoma with BAC features. CT and PET were assessed for lesion size, GGO percentage, and SUVmax. Lesions with FDG uptake the same as or more than mediastinal blood-pool activity were considered as PET-positive. Results. Of the 51 cases, 19.6% presented as pure GGO nodules, 31.4% as mixed nodules, and 49.0% as solid nodules. None of the pure GGO nodules was 18F-FDG avid, compared with 37.5% of mixed nodules and 96.0% of solid nodules (χ 2 = 31.55, P = 0.000). In the mixed nodule group, SUVmax was negatively correlated with GGO percentage (r = −0.588; P = 0.021). The positive detection rate of 18F-FDG PET/CT was 50.0%, 55.6%, and 100% in tumors 1.1–2.0 cm, 2.1–3.0 cm, and >3.0 cm in diameter, respectively (χ 2 = 5.815, P = 0.055). General linear model factor analysis showed that the GGO was an important factor contributing to false-negative PET/CT results (F = 23.992, P = 0.000), but lesion size was not (F = 0.602, P = 0.866). Conclusions. The present study indicated that the adenocarcinoma with BAC features presented as nonsolid nodule is prone to be false negative on 18F-FDG PET/CT. PMID:25879020
Trinh, Tony W; Glazer, Daniel I; Sadow, Cheryl A; Sahni, V Anik; Geller, Nina L; Silverman, Stuart G
2018-03-01
To determine test characteristics of CT urography for detecting bladder cancer in patients with hematuria and those undergoing surveillance, and to analyze reasons for false-positive and false-negative results. A HIPAA-compliant, IRB-approved retrospective review of reports from 1623 CT urograms between 10/2010 and 12/31/2013 was performed. 710 examinations for hematuria or bladder cancer history were compared to cystoscopy performed within 6 months. Reference standard was surgical pathology or 1-year minimum clinical follow-up. False-positive and false-negative examinations were reviewed to determine reasons for errors. Ninety-five bladder cancers were detected. CT urography accuracy: was 91.5% (650/710), sensitivity 86.3% (82/95), specificity 92.4% (568/615), positive predictive value 63.6% (82/129), and negative predictive value was 97.8% (568/581). Of 43 false positives, the majority of interpretation errors were due to benign prostatic hyperplasia (n = 12), trabeculated bladder (n = 9), and treatment changes (n = 8). Other causes include blood clots, mistaken normal anatomy, infectious/inflammatory changes, or had no cystoscopic correlate. Of 13 false negatives, 11 were due to technique, one to a large urinary residual, one to artifact. There were no errors in perception. CT urography is an accurate test for diagnosing bladder cancer; however, in protocols relying predominantly on excretory phase images, overall sensitivity remains insufficient to obviate cystoscopy. Awareness of bladder cancer mimics may reduce false-positive results. Improvements in CTU technique may reduce false-negative results.
Mirandola, Chiara; Toffalini, Enrico; Grassano, Massimo; Cornoldi, Cesare; Melinder, Annika
2014-01-01
The present experiment was conducted to investigate whether negative emotionally charged and arousing content of to-be-remembered scripted material would affect propensity towards memory distortions. We further investigated whether elaboration of the studied material through free recall would affect the magnitude of memory errors. In this study participants saw eight scripts. Each of the scripts included an effect of an action, the cause of which was not presented. Effects were either negatively emotional or neutral. Participants were assigned to either a yes/no recognition test group (recognition), or to a recall and yes/no recognition test group (elaboration + recognition). Results showed that participants in the recognition group produced fewer memory errors in the emotional condition. Conversely, elaboration + recognition participants had lower accuracy and produced more emotional memory errors than the other group, suggesting a mediating role of semantic elaboration on the generation of false memories. The role of emotions and semantic elaboration on the generation of false memories is discussed.
Castelló, Ana; Francès, Francesc; Verdú, Fernando
2017-09-01
Presumptive tests for blood are very simple and sensitive tests used in the search for evidence. They also provide initial information on the nature of stains. A second test can confirm their nature. However, these tests can present false-negative results for different reasons. Some of those reasons have been studied, while others, those caused by the substrate material that contains the stain, are less well known. This work studies the effect of one component of a leather substrate-quebracho extract-on presumptive and human hemoglobin blood tests. Assays were performed using samples of blood dilutions contaminated with quebracho extract and others formed on a substrate containing the contaminant. Results show an undoubted interference that causes false negatives and even visible to the naked eye stains and also indicate that some tests (phenolphthalein) are more affected than others. Examiners should be taken into account when working on this kind of substrates. © 2017 American Academy of Forensic Sciences.
Daxboeck, Florian; Dornbusch, Hans Jürgen; Krause, Robert; Assadian, Ojan; Wenisch, Christoph
2004-01-01
A small but significant proportion of blood cultures processed by the BACTEC 9000 series systems is signaled positive, while subsequent Gram's stain and culture on solid media yield no pathogens. In this study, 15 "false-positive" vials (7 aerobes, 8 anaerobes) from 15 patients were investigated for the presence of bacteria and fungi by eubacterial 16S rDNA and panfungal 18S rDNA amplification, respectively. All samples turned out negative by both methods. Most patients (7) had neutropenia, which does not support the theory that high leukocyte counts enhance the generation of false-positive results. In conclusion, the results of this study indicate that false-negative results generated by the BACTEC 9000 series are inherent to the automated detection and not due to the growth of fastidious organisms.
Analysis of false results in a series of 835 fine needle aspirates of breast lesions.
Willis, S L; Ramzy, I
1995-01-01
To analyze cases of false diagnoses from a large series to help increase the accuracy of fine needle aspiration of palpable breast lesions. The results of FNA of 835 palpable breast lesions were analyzed to determine the reasons for false positive, false negative and false suspicious diagnoses. Of the 835 aspirates, 174 were reported as positive, 549 as negative and 66 as suspicious or atypical but not diagnostic of malignancy. Forty-six cases were considered unsatisfactory. Tissue was available for comparison in 286 cases. The cytologic diagnoses in these cases were reported as follows: positive, 125 (43.7%); suspicious, 33 (11.5%); atypical, 18 (6.2%); negative, 92 (32%); and unsatisfactory, 18 (6.2%). There was one false positive diagnosis, yielding a false positive rate of 0.8%. This lesion was a case of fibrocystic change with hyperplasia, focal fat necrosis and reparative atypia. There were 14 false negative cases, resulting in a false negative rate of 13.2%. Nearly all these cases were sampling errors and included infiltrating ductal carcinomas (9), ductal carcinomas in situ (2), infiltrating lobular carcinomas (2) and tubular carcinoma (1). Most of the suspicious and atypical lesions proved to be carcinomas (35/50). The remainder were fibroadenomas (6), fibrocystic change (4), gynecomastia (2), adenosis (2) and granulomatous mastitis (1). A positive diagnosis of malignancy by FNA is reliable in establishing the diagnosis and planning the treatment of breast cancer. The false-positive rate is very low, with only a single case reported in 835 aspirates. Most false negatives are due to sampling and not to interpretive difficulties. The category "suspicious but not diagnostic of malignancy" serves a useful purpose in management of patients with breast lumps.
Nieuwland, Mante S.; Kuperberg, Gina R.
2011-01-01
Our brains rapidly map incoming language onto what we hold to be true. Yet there are claims that such integration and verification processes are delayed in sentences containing negation words like ‘not’. However, research studies have often confounded whether a statement is true and whether it is natural thing to say during normal communication. In an event-related potential (ERP) experiment, we aimed to disentangle effects of truth-value and pragmatic licensing on the comprehension of affirmative and negated real-world statements. As in affirmative sentences, false words elicited a larger N400 ERP than true words in pragmatically licensed negated sentences (e.g., “In moderation, drinking red wine isn’t bad/good…”), whereas true and false words elicited similar responses in unlicensed negated sentences (e.g., “A baby bunny’s fur isn’t very hard/soft…”). These results suggest that negation poses no principled obstacle for readers to immediately relate incoming words to what they hold to be true. PMID:19121125
2012-01-01
Background We previously investigated the current status of breast cytology cancer screening at seven institutes in our area of southern Fukuoka Prefecture, and found some differences in diagnostic accuracy among the institutions. In the present study, we evaluated the cases involved and noted possible reasons for their original cytological classification as inadequate, indeterminate, false-negative and false-positive according to histological type. Methods We evaluated the histological findings in 5693 individuals who underwent cytological examination for breast cancer (including inadequate, indeterminate, false-negative and false-positive cases), to determine the most common histological types and/or features in these settings and the usefulness/limitations of cytological examination for the diagnosis of breast cancer. Results Among 1152 cytologically inadequate cases, histology revealed that 75/173 (43.6%) cases were benign, including mastopathy (fibrocystic disease) in 38.6%, fibroadenoma in 24.0% and papilloma in 5.3%. Ninety-five of 173 (54.9%) cases were histologically malignant, with scirrhous growing type, invasive ductal carcinoma (SIDC) being significantly more frequent (49.5%) than papillotubular growing type (Papi-tub) (P < 0.0001), solid-tubular growing type (P = 0.0001) and ductal carcinoma in situ (DCIS) (P = 0.0001). Among 458 indeterminate cases, 54/139 (38.8%) were histologically benign (mastopathy, 30.0%; fibroadenoma, 27.8%; papilloma, 26.0%) and 73/139 (52.5%) were malignant, with SIDC being the most frequent malignant tumor (37.0%). Among 52 false-negative cases, SIDC was significantly more frequent (42.3%) than DCIS (P = 0.0049) and Papi-tub (P = 0.001). There were three false-positive cases, with one each of fibroadenoma, epidermal cyst and papilloma. Conclusions The inadequate, indeterminate, false-negative and false-positive cases showed similar histological types, notably SIDC for malignant tumors, and mastopathy, fibroadenoma and papilloma for benign cases. We need to pay particular attention to the collection and assessment of aspirates for these histological types of breast disease. In particular, several inadequate, indeterminate and false-negative cases with samples collected by aspiration were diagnosed as SIDC. These findings should encourage the use of needle biopsy rather than aspiration when this histological type is identified on imaging. Namely, good communication between clinicians and pathological staff, and triple assessment (i.e., clinical, pathological and radiological assessment), are important for accurate diagnosis of aspiration samples. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/7349809170055423 PMID:22607447
Ahmadinejad, Mojtaba; Aliepour, Asghar; Anbari, Khatereh; Kaviani, Mojhgan; Ganjizadeh, Hasan; Nadri, Sedigheh; Foroutani, Niloufar; Meysami, Masoumeh; Almasi, Vahid
2015-12-01
Several methods are used to evaluate the thyroid nodules. The aim of this study was to determine the sensitivity, specificity, false positive and negative rates, positive predictive value (PPV), and negative predictive value (NPV) of touch imprint, crush preparation, and fine-needle aspiration (FNA) methods. This cross-sectional study was done in Shohada-ye Ashayer University Hospital in Khorramabad. All the patients who underwent thyroid surgery due to thyroid nodules in this hospital between March and September 2011 were evaluated. The thyroid nodules of all the patients were evaluated by touch imprint, crush preparation, FNA, and permanent pathology methods. Finally, the results of the first three methods were compared with the result of permanent pathology method. The mean age of 104 patients who underwent thyroid surgery was 42.6 ± 11.9 years old. Based on permanent pathology, touch imprint, crush preparation, and FNA methods, 15.3, 6.25, 6.25, and 4.4 % of thyroid nodules were malignant, respectively. Sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of FNA biopsy were 62.5, 100, 0, 37.5, 100, and 95.3 %, respectively. Also, sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of touch imprint and crush preparation were equal and were 80, 100, 0, 20, 100, and 96.7 %, respectively. Using touch imprint and crush preparation in evaluation of thyroid nodules for rapid evaluation of these nodules in operating rooms seems to be logical, and it can prevent further surgeries.
Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho
2014-01-01
Background: This study was conducted to evaluate the diagnostic validity of the 13C-urea breath test (13C-UBT) in the remnant stomach after partial gastrectomy for gastric cancer. Methods: The 13C-UBT results after Helicobacter pylori eradication therapy was compared with the results of endoscopic biopsy-based methods in the patients who have received partial gastrectomy for the gastric cancer. Results: Among the gastrectomized patients who showed the positive 13C-UBT results (≥ 2.5‰, n = 47) and negative 13C-UBT results (< 2.5‰, n = 114) after H. pylori eradication, 26 patients (16.1%) and 4 patients (2.5%) were found to show false positive and false negative results based on biopsy-based methods, respectively. The sensitivity, specificity, false positive rate, and false negative rate for the cut-off value of 2.5‰ were 84.0%, 80.9%, 19.1%, and 16.0%, respectively. The positive and negative predictive values were 44.7% and 96.5%, respectively. In the multivariate analysis, two or more H. pylori eradication therapies (odds ratio = 3.248, 95% confidence interval= 1.088–9.695, P = 0.035) was associated with a false positive result of the 13C-UBT. Conclusions: After partial gastrectomy, a discordant result was shown in the positive 13C-UBT results compared to the endoscopic biopsy methods for confirming the H. pylori status after eradication. Additional endoscopic biopsy-based H. pylori tests would be helpful to avoid unnecessary treatment for H. pylori eradication in these cases. PMID:25574466
Monds, Lauren A; Paterson, Helen M; Kemp, Richard I
2017-09-01
Many eyewitness memory situations involve negative and distressing events; however, many studies investigating "false memory" phenomena use neutral stimuli only. The aim of the present study was to determine how both the Deese-Roediger-McDermott (DRM) procedure and the Misinformation Effect Paradigm tasks were related to each other using distressing and neutral stimuli. Participants completed the DRM (with negative and neutral word lists) and viewed a distressing or neutral film. Misinformation for the film was introduced and memory was assessed. Film accuracy and misinformation susceptibility were found to be greater for those who viewed the distressing film relative to the neutral film. Accuracy responses on both tasks were related, however, susceptibility to the DRM illusion and Misinformation Effect were not. The misinformation findings support the Paradoxical Negative Emotion (PNE) hypothesis that negative stimuli will lead to remembering more accurate details but also greater likelihood of memory distortion. However, the PNE hypothesis was not supported for the DRM results. The findings also suggest that the DRM and Misinformation tasks are not equivalent and may have differences in underlying mechanisms. Future research should focus on more ecologically valid methods of assessing false memory.
Breast cancers not detected at MRI: review of false-negative lesions.
Shimauchi, Akiko; Jansen, Sanaz A; Abe, Hiroyuki; Jaskowiak, Nora; Schmidt, Robert A; Newstead, Gillian M
2010-06-01
The objective of our study was to determine the sensitivity of cancer detection at breast MRI using current imaging techniques and to evaluate the characteristics of lesions with false-negative examinations. Two hundred seventeen patients with 222 newly diagnosed breast cancers or highly suspicious breast lesions that were subsequently shown to be malignant underwent breast MRI examinations for staging. Two breast imaging radiologists performed a consensus review of the breast MRI examinations. The absence of perceptible contrast enhancement at the expected site was considered to be a false-negative MRI. Histology of all lesions was reviewed by an experienced breast pathologist. Enhancement was observed in 213 (95.9%) of the 222 cancer lesions. Of the nine lesions without visible enhancement, two lesions were excluded because the entire tumor had been excised at percutaneous biopsy performed before the MRI examination and no residual tumor was noted on the final histology. The overall sensitivity of MRI for the known cancers was 96.8% (213/220); for invasive cancer, 98.3% (176/179); and for ductal carcinoma in situ, 90.2% (37/41). In a population of 220 sequentially diagnosed breast cancer lesions, we found seven (3.2%) MRI-occult cancers, fewer than seen in other published studies. Small tumor size and diffuse parenchymal enhancement were the principal reasons for these false-negative results. Although the overall sensitivity of cancer detection was high (96.8%), it should be emphasized that a negative MRI should not influence the management of a lesion that appears to be of concern on physical examination or on other imaging techniques.
Hofvind, Solveig; Sagstad, Silje; Sebuødegård, Sofie; Chen, Ying; Roman, Marta; Lee, Christoph I
2018-04-01
Purpose To compare rates and tumor characteristics of interval breast cancers (IBCs) detected after a negative versus false-positive screening among women participating in the Norwegian Breast Cancer Screening Program. Materials and Methods The Cancer Registry Regulation approved this retrospective study. Information about 423 445 women aged 49-71 years who underwent 789 481 full-field digital mammographic screening examinations during 2004-2012 was extracted from the Cancer Registry of Norway. Rates and odds ratios of IBC among women with a negative (the reference group) versus a false-positive screening were estimated by using logistic regression models adjusted for age at diagnosis and county of residence. Results A total of 1302 IBCs were diagnosed after 789 481 screening examinations, of which 7.0% (91 of 1302) were detected among women with a false-positive screening as the most recent breast imaging examination before detection. By using negative screening as the reference, adjusted odds ratios of IBCs were 3.3 (95% confidence interval [CI]: 2.6, 4.2) and 2.8 (95% CI: 1.8, 4.4) for women with a false-positive screening without and with needle biopsy, respectively. Women with a previous negative screening had a significantly lower proportion of tumors that were 10 mm or less (14.3% [150 of 1049] vs 50.0% [seven of 14], respectively; P < .01) and grade I tumors (13.2% [147 of 1114] vs 42.9% [six of 14]; P < .01), but a higher proportion of cases with lymph nodes positive for cancer (40.9% [442 of 1080] vs 13.3% [two of 15], respectively; P = .03) compared with women with a previous false-positive screening with benign biopsy. A retrospective review of the screening mammographic examinations identified 42.9% (39 of 91) of the false-positive cases to be the same lesion as the IBC. Conclusion By using a negative screening as the reference, a false-positive screening examination increased the risk of an IBC three-fold. The tumor characteristics of IBC after a negative screening were less favorable compared with those detected after a previous false-positive screening. © RSNA, 2017 Online supplemental material is available for this article.
Kozycki, Christina T; Umulisa, Noella; Rulisa, Stephen; Mwikarago, Emil I; Musabyimana, Jean Pierre; Habimana, Jean Pierre; Karema, Corine; Krogstad, Donald J
2017-03-20
Rapid diagnostic tests (RDTs) for histidine rich protein 2 (HRP2) are often used to determine whether persons with fever should be treated with anti-malarials. However, Plasmodium falciparum parasites with a deletion of the hrp2 gene yield false-negative RDTs and there are concerns the sensitivity of HRP2-based RDTs may fall when the intensity of transmission decreases. This observational study enrolled 9226 patients at three health centres in Rwanda from April 2014 to April 2015. It then compared the sensitivity of RDTs based on HRP2 and the Plasmodium lactate dehydrogenase (pLDH) to microscopy (thick smears) for the diagnosis of malaria. PCR was used to determine whether deletions of the histidine-rich central repeat region of the hrp2 gene (exon 2) were associated with false-negative HRP2-based RDTs. In comparison to microscopy, the sensitivity and specificity of HRP2- and pLDH-based RDTs were 89.5 and 86.2% and 80.2 and 94.3%, respectively. When the results for both RDTs were combined, sensitivity rose to 91.8% and specificity was 85.7%. Additionally, when smear positivity fell from 46 to 3%, the sensitivity of the HRP2-based RDT fell from 88 to 67%. Of 370 samples with false-negative HRP2 RDT results for which PCR was performed, 140 (38%) were identified as P. falciparum by PCR. Of the isolates identified as P. falciparum by PCR, 32 (23%) were negative for the hrp2 gene based on PCR. Of the 32 P. falciparum isolates negative for hrp2 by PCR, 17 (53%) were positive based on the pLDH RDT. This prospective study of RDT performance coincided with a decline in the intensity of malaria transmission in Kibirizi (fall in slide positivity from 46 to 3%). This decline was associated with a decrease in HRP2 RDT sensitivity (from 88 to 67%). While P. falciparum isolates without the hrp2 gene were an important cause of false-negative HRP2-based RDTs, most were identified by the pLDH-based RDT. Although WHO does not recommend the use of combined HRP2/pLDH testing in sub-Saharan Africa, these results suggest that combination HRP2/pLDH-based RDTs could reduce the impact of false-negative HRP2-based RDTs for detection of symptomatic P. falciparum malaria.
Yoon, Jung Hyun; Jung, Hae Kyoung; Lee, Jong Tae; Ko, Kyung Hee
2013-09-01
To investigate the factors that have an effect on false-positive or false-negative shear-wave elastography (SWE) results in solid breast masses. From June to December 2012, 222 breast lesions of 199 consecutive women (mean age: 45.3 ± 10.1 years; range, 21 to 88 years) who had been scheduled for biopsy or surgical excision were included. Greyscale ultrasound and SWE were performed in all women before biopsy. Final ultrasound assessments and SWE parameters (pattern classification and maximum elasticity) were recorded and compared with histopathology results. Patient and lesion factors in the 'true' and 'false' groups were compared. Of the 222 masses, 175 (78.8 %) were benign, and 47 (21.2 %) were malignant. False-positive rates of benign masses were significantly higher than false-negative rates of malignancy in SWE patterns, 36.6 % to 6.4 % (P < 0.001). Among both benign and malignant masses, factors showing significance among false SWE features were lesion size, breast thickness and lesion depth (all P < 0.05). All 47 malignant breast masses had SWE images of good quality. False SWE features were more significantly seen in benign masses. Lesion size, breast thickness and lesion depth have significance in producing false results, and this needs consideration in SWE image acquisition. • Shear-wave elastography (SWE) is widely used during breast imaging • At SWE, false-positive rates were significantly higher than false-negative rates • Larger size, breast thickness, depth and fair quality influences false-positive SWE features • Smaller size, larger breast thickness and depth influences false-negative SWE features.
Park, So Yoon; Choi, Ji Soo; Han, Boo-Kyung; Ko, Eun Young; Ko, Eun Sook
2017-09-01
To investigate factors related to false shear wave elastography (SWE) results for breast non-mass lesions (NMLs) detected by B-mode US. This retrospective study enrolled 152 NMLs detected by B-mode US and later pathologically confirmed (79 malignant, 73 benign). All lesions underwent B-mode US and SWE. Quantitative (mean elasticity [E mean ]) and qualitative (maximum stiffness colour) SWE parameters were assessed, and 'E mean > 85.1 kPa' or 'stiff colour (green to red)' determined malignancy. Final SWE results were matched to pathology results. Multivariate logistic regression analysis identified factors associated with false SWE results for diagnosis of breast NMLs. Associated calcifications (E mean : odds ratio [OR] = 7.60, P < 0.01; maximum stiffness colour: OR = 6.30, P = 0.02), in situ cancer compared to invasive cancer (maximum stiffness colour: OR = 5.29, P = 0.02), and lesion size (E mean : OR = 0.90, P < 0.01; maximum stiffness colour: OR = 0.91, P = 0.01) were significantly associated with false negative SWE results for malignant NMLs. Distance from the nipple (E mean : OR = 0.84, P = 0.03; maximum stiffness colour: OR = 0.93, P = 0.04) was significantly associated with false positive SWE results for benign NMLs. Presence of associated calcifications, absence of the invasive component, and smaller lesion size for malignant NMLs and shorter distance from the nipple for benign NMLs are factors significantly associated with false SWE results. • Calcification and size are associated with false negative SWE in malignant NMLs. • In situ cancer is associated with false negative SWE in malignant NMLs. • Distance from the nipple is associated with false positive SWE in benign NMLs. • These factors need consideration when performing SWE on breast NMLs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berquist, T.H.; Nolan, N.G.; Stephens, D.H.
1976-06-01
Numerous reports in the recent literature have questioned the value of abdominal scanning with pertechnetate in the diagnosis of Meckel's diverticulum. In an attempt to evaluate further the specificity of pertechnetate in this condition, the clinical data and scintigrams of 100 patients with suspected Meckel's diverticulum were reviewed. The scintigram correctly identified Meckel's diverticulum before operation in seven of eight patients. One false-negative study occurred in 33 patients who underwent laparotomy. Conditions suggested as possible causes of false-positive studies (hydronephrosis, arteriovenous malformations, and intussusception) were found to give negative scans. (auth)
Lucovnik, Miha; Chambliss, Linda R; Blumrick, Richard; Balducci, James; Gersak, Ksenija; Garfield, Robert E
2016-10-01
It has been shown that noninvasive uterine electromyography (EMG) can identify true preterm labor more accurately than methods available to clinicians today. The objective of this study was to evaluate the effect of body mass index (BMI) on the accuracy of uterine EMG in predicting preterm delivery. Predictive values of uterine EMG for preterm delivery were compared in obese versus overweight/normal BMI patients. Hanley-McNeil test was used to compare receiver operator characteristics curves in these groups. Previously reported EMG cutoffs were used to determine groups with false positive/false negative and true positive/true negative EMG results. BMI in these groups was compared with Student t test (p < 0.05 significant). A total of 88 patients were included: 20 obese, 64 overweight, and four with normal BMI. EMG predicted preterm delivery within 7 days with area under the curve = 0.95 in the normal/overweight group, and with area under the curve = 1.00 in the obese group (p = 0.08). Six patients in true preterm labor (delivering within 7 days from EMG measurement) had low EMG values (false negative group). There were no false positive results. No significant differences in patient's BMI were noted between false negative group patients and preterm labor patients with high EMG values (true positive group) and nonlabor patients with low EMG values (true negative group; p = 0.32). Accuracy of noninvasive uterine EMG monitoring and its predictive value for preterm delivery are not affected by obesity. Copyright © 2016. Published by Elsevier B.V.
Application of Immunosignatures for Diagnosis of Valley Fever
Navalkar, Krupa Arun; Johnston, Stephen Albert; Woodbury, Neal; Galgiani, John N.; Magee, D. Mitchell; Chicacz, Zbigniew
2014-01-01
Valley fever (VF) is difficult to diagnose, partly because the symptoms of VF are confounded with those of other community-acquired pneumonias. Confirmatory diagnostics detect IgM and IgG antibodies against coccidioidal antigens via immunodiffusion (ID). The false-negative rate can be as high as 50% to 70%, with 5% of symptomatic patients never showing detectable antibody levels. In this study, we tested whether the immunosignature diagnostic can resolve VF false negatives. An immunosignature is the pattern of antibody binding to random-sequence peptides on a peptide microarray. A 10,000-peptide microarray was first used to determine whether valley fever patients can be distinguished from 3 other cohorts with similar infections. After determining the VF-specific peptides, a small 96-peptide diagnostic array was created and tested. The performances of the 10,000-peptide array and the 96-peptide diagnostic array were compared to that of the ID diagnostic standard. The 10,000-peptide microarray classified the VF samples from the other 3 infections with 98% accuracy. It also classified VF false-negative patients with 100% sensitivity in a blinded test set versus 28% sensitivity for ID. The immunosignature microarray has potential for simultaneously distinguishing valley fever patients from those with other fungal or bacterial infections. The same 10,000-peptide array can diagnose VF false-negative patients with 100% sensitivity. The smaller 96-peptide diagnostic array was less specific for diagnosing false negatives. We conclude that the performance of the immunosignature diagnostic exceeds that of the existing standard, and the immunosignature can distinguish related infections and might be used in lieu of existing diagnostics. PMID:24964807
Johnson, Cheryl C.; Fonner, Virginia; Sands, Anita; Ford, Nathan; Obermeyer, Carla Mahklouf; Tsui, Sharon; Wong, Vincent; Baggaley, Rachel
2017-01-01
Abstract Introduction: In accordance with global testing and treatment targets, many countries are seeking ways to reach the “90-90-90” goals, starting with diagnosing 90% of all people with HIV. Quality HIV testing services are needed to enable people with HIV to be diagnosed and linked to treatment as early as possible. It is essential that opportunities to reach people with undiagnosed HIV are not missed, diagnoses are correct and HIV-negative individuals are not inadvertently initiated on life-long treatment. We conducted this systematic review to assess the magnitude of misdiagnosis and to describe poor HIV testing practices using rapid diagnostic tests. Methods: We systematically searched peer-reviewed articles, abstracts and grey literature published from 1 January 1990 to 19 April 2017. Studies were included if they used at least two rapid diagnostic tests and reported on HIV misdiagnosis, factors related to potential misdiagnosis or described quality issues and errors related to HIV testing. Results: Sixty-four studies were included in this review. A small proportion of false positive (median 3.1%, interquartile range (IQR): 0.4-5.2%) and false negative (median: 0.4%, IQR: 0-3.9%) diagnoses were identified. Suboptimal testing strategies were the most common factor in studies reporting misdiagnoses, particularly false positive diagnoses due to using a “tiebreaker” test to resolve discrepant test results. A substantial proportion of false negative diagnoses were related to retesting among people on antiretroviral therapy. Conclusions: HIV testing errors and poor practices, particularly those resulting in false positive or false negative diagnoses, do occur but are preventable. Efforts to accelerate HIV diagnosis and linkage to treatment should be complemented by efforts to improve the quality of HIV testing services and strengthen the quality management systems, particularly the use of validated testing algorithms and strategies, retesting people diagnosed with HIV before initiating treatment and providing clear messages to people with HIV on treatment on the risk of a “false negative” test result. PMID:28872271
Saingam, Prakit; Li, Bo; Yan, Tao
2018-06-01
DNA-based molecular detection of microbial pathogens in complex environments is still plagued by sensitivity, specificity and robustness issues. We propose to address these issues by viewing them as inadvertent consequences of requiring specific and adequate amplification (SAA) of target DNA molecules by current PCR methods. Using the invA gene of Salmonella as the model system, we investigated if next generation sequencing (NGS) can be used to directly detect target sequences in false-negative PCR reaction (PCR-NGS) in order to remove the SAA requirement from PCR. False-negative PCR and qPCR reactions were first created using serial dilutions of laboratory-prepared Salmonella genomic DNA and then analyzed directly by NGS. Target invA sequences were detected in all false-negative PCR and qPCR reactions, which lowered the method detection limits near the theoretical minimum of single gene copy detection. The capability of the PCR-NGS approach in correcting false negativity was further tested and confirmed under more environmentally relevant conditions using Salmonella-spiked stream water and sediment samples. Finally, the PCR-NGS approach was applied to ten urban stream water samples and detected invA sequences in eight samples that would be otherwise deemed Salmonella negative. Analysis of the non-target sequences in the false-negative reactions helped to identify primer dime-like short sequences as the main cause of the false negativity. Together, the results demonstrated that the PCR-NGS approach can significantly improve method sensitivity, correct false-negative detections, and enable sequence-based analysis for failure diagnostics in complex environmental samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Statistical approaches to account for false-positive errors in environmental DNA samples.
Lahoz-Monfort, José J; Guillera-Arroita, Gurutzeta; Tingley, Reid
2016-05-01
Environmental DNA (eDNA) sampling is prone to both false-positive and false-negative errors. We review statistical methods to account for such errors in the analysis of eDNA data and use simulations to compare the performance of different modelling approaches. Our simulations illustrate that even low false-positive rates can produce biased estimates of occupancy and detectability. We further show that removing or classifying single PCR detections in an ad hoc manner under the suspicion that such records represent false positives, as sometimes advocated in the eDNA literature, also results in biased estimation of occupancy, detectability and false-positive rates. We advocate alternative approaches to account for false-positive errors that rely on prior information, or the collection of ancillary detection data at a subset of sites using a sampling method that is not prone to false-positive errors. We illustrate the advantages of these approaches over ad hoc classifications of detections and provide practical advice and code for fitting these models in maximum likelihood and Bayesian frameworks. Given the severe bias induced by false-negative and false-positive errors, the methods presented here should be more routinely adopted in eDNA studies. © 2015 John Wiley & Sons Ltd.
[Relevance of the sentinel lymph node biopsy in breast multifocal and multicentric cancer].
Mosbah, R; Raimond, E; Pelissier, A; Hocedez, C; Graesslin, O
2015-05-01
The sentinel lymph node biopsy is a gold standard in the management of breast cancer. Its role in multifocal or multicentric tumors is still evolving. The aim of this study is to assess the feasibility and pertinence of sentinel lymph node biopsy in multifocal and multicentric tumors based on a systematic review of literature. A systematic review was conducted searching in the following electronic databases PubMed using "sentinel lymph node biopsy", "breast cancer", "multifocal tumor", "multicentric tumor" and "multiple tumor" as keywords. We included original articles published between 2000 and 2014, both French and English, studying feasibility of sentinel lymph node biopsy in invasive breast cancer, multicentric and/or multifocal tumors. The first end point was success rate and false negative rate. Twenty-six articles were included in this literature review, with 2212 cases (782 multifocal, 737 multicentric and 693 multiple tumors). Percentage of tumors whose stage was higher than stage T2 ranged from 0 to 86.3%. Success rate average was 83.1%. False negative average was 8.2%. False negative rate was less than 10% in 15 articles. Mean of sentinel lymph node biopsy was 2 (1-9). The average rate of sentinel lymph node positive was 50.6%. Axillary recurrence rate was 0.5%. Despite the methodological biases of the studies included in this review of literature, the false negative rate of sentinel node biopsy in multifocal and multicentric breast cancers are less than 10% with a low rate of axillary recurrence. Despite the lack of randomized study, this procedure can be routinely performed in accordance with rigorous technical process. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Hydrogen breath test in schoolchildren.
Douwes, A C; Schaap, C; van der Klei-van Moorsel, J M
1985-01-01
The frequency of negative hydrogen breath tests due to colonic bacterial flora which are unable to produce hydrogen was determined after oral lactulose challenge in 98 healthy Dutch schoolchildren. There was a negative result in 9.2%. The probability of a false normal lactose breath test (1:77) was calculated from these results together with those from a separate group of children with lactose malabsorption (also determined by hydrogen breath test). A study of siblings and mothers of subjects with a negative breath test did not show familial clustering of this condition. Faecal incubation tests with various sugars showed an increase in breath hydrogen greater than 100 parts per million in those with a positive breath test while subjects with a negative breath test also had a negative faecal incubation test. The frequency of a false negative hydrogen breath test was higher than previously reported, but this does not affect the superiority of this method of testing over the conventional blood glucose determination. PMID:4004310
[Roaming through methodology. XXXII. False test results].
van der Weijden, T; van den Akker, M
2001-05-12
The number of requests for diagnostic tests is rising. This leads to a higher chance of false test results. The false-negative proportion of a test is the proportion of negative test results among the diseased subjects. The false-positive proportion is the proportion of positive test results among the healthy subjects. The calculation of the false-positive proportion is often incorrect. For example, instead of 1 minus the specificity it is calculated as 1 minus the positive predictive value. This can lead to incorrect decision-making with respect to the application of the test. Physicians must apply diagnostic tests in such a way that the risk of false test results is minimal. The patient should be aware that a perfectly conclusive diagnostic test is rare in medical practice, and should more often be informed of the implications of false-positive and false-negative test results.
Finite mixture modeling for vehicle crash data with application to hotspot identification.
Park, Byung-Jung; Lord, Dominique; Lee, Chungwon
2014-10-01
The application of finite mixture regression models has recently gained an interest from highway safety researchers because of its considerable potential for addressing unobserved heterogeneity. Finite mixture models assume that the observations of a sample arise from two or more unobserved components with unknown proportions. Both fixed and varying weight parameter models have been shown to be useful for explaining the heterogeneity and the nature of the dispersion in crash data. Given the superior performance of the finite mixture model, this study, using observed and simulated data, investigated the relative performance of the finite mixture model and the traditional negative binomial (NB) model in terms of hotspot identification. For the observed data, rural multilane segment crash data for divided highways in California and Texas were used. The results showed that the difference measured by the percentage deviation in ranking orders was relatively small for this dataset. Nevertheless, the ranking results from the finite mixture model were considered more reliable than the NB model because of the better model specification. This finding was also supported by the simulation study which produced a high number of false positives and negatives when a mis-specified model was used for hotspot identification. Regarding an optimal threshold value for identifying hotspots, another simulation analysis indicated that there is a discrepancy between false discovery (increasing) and false negative rates (decreasing). Since the costs associated with false positives and false negatives are different, it is suggested that the selected optimal threshold value should be decided by considering the trade-offs between these two costs so that unnecessary expenses are minimized. Copyright © 2014 Elsevier Ltd. All rights reserved.
Van Damme, Ilse; Smets, Karolien
2014-04-01
Research has shown that emotional events are remembered better than neutral events, but might also elicit an increase in false memories. The present study was designed to disentangle the influences of valence and arousal on event memory in the misinformation paradigm. Participants were shown six types of photographs (positive with high/low arousal, negative with high/low arousal, ambiguous, neutral), after which half of them were exposed to misleading information. A recognition test assessed memory for both correct and false central and peripheral details. Negative and ambiguous events elicited fewer correct and more false memories for peripheral details than positive and neutral events, regardless of previous exposure to misinformation. Arousal improved memory for correct central details, and both negative valence and arousal inhibited control participants' tendency to endorse false central details. The power of emotion was overruled by the power of suggestion, however, as the latter effect disappeared with previous exposure to misinformation. Results are discussed in the light of earlier research on emotion and cognition, recent motivational theories, and implications for forensic practice.
Children's False Memory and True Disclosure in the Face of Repeated Questions
ERIC Educational Resources Information Center
Schaaf, Jennifer M.; Alexander, Kristen Weede; Goodman, Gail S.
2008-01-01
The current study was designed to investigate children's memory and suggestibility for events differing in valence (positive or negative) and veracity (true or false). A total of 82 3- and 5-year-olds were asked repeated questions about true and false events, either in a grouped order (i.e., all questions about a certain event asked consecutively)…
Motivated reconstruction: The effect of brand commitment on false memories.
Montgomery, Nicole Votolato; Rajagopal, Priyali
2018-06-01
Across 5 studies, we examine the effect of prior brand commitment on the creation of false memories about product experience after reading online product reviews. We find that brand commitment and the valence of reviews to which consumers are exposed, interact to affect the incidence of false memories. Thus, highly committed consumers are more susceptible to the creation of false experience memories on exposure to positive versus negative reviews, whereas low commitment consumers exhibit similar levels of false memories in response to both positive and negative reviews. Further, these differences across brand commitment are attenuated when respondents are primed with an accuracy motivation, suggesting that the biasing effects of commitment are likely because of the motivation to defend the committed brand. Finally, we find that differences in false memories subsequently lead to differences in intentions to spread word-of-mouth (e.g., recommend the product to friends), suggesting that the consequences of false product experience memories can be significant for marketers and consumers. Our findings contribute to the literatures in false memory and marketing by documenting a motivated bias in false memories because of brand commitment. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Graff, L; Russell, J; Seashore, J; Tate, J; Elwell, A; Prete, M; Werdmann, M; Maag, R; Krivenko, C; Radford, M
2000-11-01
To test the hypothesis that physician errors (failure to diagnose appendicitis at initial evaluation) correlate with adverse outcome. The authors also postulated that physician errors would correlate with delays in surgery, delays in surgery would correlate with adverse outcomes, and physician errors would occur on patients with atypical presentations. This was a retrospective two-arm observational cohort study at 12 acute care hospitals: 1) consecutive patients who had an appendectomy for appendicitis and 2) consecutive emergency department abdominal pain patients. Outcome measures were adverse events (perforation, abscess) and physician diagnostic performance (false-positive decisions, false-negative decisions). The appendectomy arm of the study included 1, 026 patients with 110 (10.5%) false-positive decisions (range by hospital 4.7% to 19.5%). Of the 916 patients with appendicitis, 170 (18.6%) false-negative decisions were made (range by hospital 10.6% to 27.8%). Patients who had false-negative decisions had increased risks of perforation (r = 0.59, p = 0.058) and of abscess formation (r = 0.81, p = 0.002). For admitted patients, when the inhospital delay before surgery was >20 hours, the risk of perforation was increased [2.9 odds ratio (OR) 95% CI = 1.8 to 4.8]. The amount of delay from initial physician evaluation until surgery varied with physician diagnostic performance: 7.0 hours (95% CI = 6.7 to 7.4) if the initial physician made the diagnosis, 72.4 hours (95% CI = 51.2 to 93.7) if the initial office physician missed the diagnosis, and 63.1 hours (95% CI = 47.9 to 78.4) if the initial emergency physician missed the diagnosis. Patients whose diagnosis was initially missed by the physician had fewer signs and symptoms of appendicitis than patients whose diagnosis was made initially [appendicitis score 2.0 (95% CI = 1.6 to 2.3) vs 6.5 (95% CI = 6.4 to 6.7)]. Older patients (>41 years old) had more false-negative decisions and a higher risk of perforation or abscess (3.5 OR 95% CI = 2.4 to 5.1). False-positive decisions were made for patients who had signs and symptoms similar to those of appendicitis patients [appendicitis score 5.7 (95% CI = 5.2 to 6.1) vs 6.5 (95% CI = 6.4 to 6.7)]. Female patients had an increased risk of false-positive surgery (2.3 OR 95% CI = 1.5 to 3.4). The abdominal pain arm of the study included 1,118 consecutive patients submitted by eight hospitals, with 44 patients having appendicitis. Hospitals with observation units compared with hospitals without observation units had a higher "rule out appendicitis" evaluation rate [33.7% (95% CI = 27 to 38) vs 24.7% (95% CI = 23 to 27)] and a similar hospital admission rate (27.6% vs 24.7%, p = NS). There was a lower miss-diagnosis rate (15.1% vs 19.4%, p = NS power 0.02), lower perforation rate (19.0% vs 20.6%, p = NS power 0.05), and lower abscess rate (5.6% vs 6.9%, p = NS power 0.06), but these did not reach statistical significance. Errors in physician diagnostic decisions correlated with patient clinical findings, i.e., the missed diagnoses were on appendicitis patients with few clinical findings and unnecessary surgeries were on non-appendicitis patients with clinical findings similar to those of patients with appendicitis. Adverse events (perforation, abscess formation) correlated with physician false-negative decisions.
Meller, J; Köster, G; Liersch, T; Siefker, U; Lehmann, K; Meyer, I; Schreiber, K; Altenvoerde, G; Becker, W
2002-01-01
Indium-111-labelled white blood cells ((111)In-WBCs) are currently considered the tracer of choice in the diagnostic work-up of suspected active chronic osteomyelitis (COM). Previous studies in a limited number of patients, performed with dedicated PET systems, have shown that [(18)F]2'-deoxy-2-fluoro- D-glucose (FDG) imaging may offer at least similar diagnostic accuracy. The aim of this prospective study was to compare FDG imaging with a dual-head coincidence camera (DHCC) and (111)In-WBC imaging in patients with suspected COM. Thirty consecutive non-diabetic patients with possible COM underwent combined skeletal scintigraphy (30/30 patients), (111)In-WBC imaging (28/30 patients) and FDG-PET with a DHCC (30/30 patients). During diagnostic work-up, COM was proven in 11/36 regions of suspected skeletal infection and subsequently excluded in 25/36 regions. In addition, soft tissue infection was present in five patients and septic arthritis in three. (111)In-WBC imaging in 28 patients was true positive in 2/11 regions with proven COM and true negative in 21/23 regions without further evidence of COM. False-positive results occurred in two regions and false-negative results in nine regions suspected for COM. Most of the false-negative results (7/9) occurred in the central skeleton. If the analysis was restricted to the 18 regions with available histology ( n=17) or culture ( n=1), (111)In-WBC imaging was true positive in 2/18 regions, true negative in 8/18 regions, false negative in 7/18 regions and false positive in 1/18 regions. FDG-DHCC imaging was true positive in 11/11 regions with proven COM and true negative in 23/25 regions without further evidence of COM. False-positive results occurred in two regions. If the analysis was restricted to the 19 regions with available histology ( n=18) or culture ( n=1), FDG-DHCC imaging was true positive in 9/9 regions with proven COM and true negative in 10/10 regions without further evidence of COM. It is concluded that FDG-DHCC imaging is superior to (111)In-WBC scintigraphy in the diagnosis of COM in the central skeleton and therefore should be considered the method of choice for this indication. This seems to hold true for peripheral lesions as well, but in our series the number of cases with proven infection was too small to permit a final conclusion.
Folli, Secondo; Falco, Giuseppe; Mingozzi, Matteo; Buggi, Federico; Curcio, Annalisa; Ferrari, Guglielmo; Taffurelli, Mario; Regolo, Lea; Nanni, Oriana
2016-04-01
Patients with ipsilateral breast tumor recurrence or new ipsilateral primary tumor after previous breast conservative surgery with negative sentinel lymph node biopsy need a new axillary staging procedure. However, the best surgical option, i.e. repeat sentinel lymph node biopsy or axillary lymph node dissection, is still debated. Purpose of the study is to assess the performance of repeat sentinel lymph node biopsy. In a multicenter study, lymph node biopsy completed by back-up axillary lymph node dissection was undertaken for ipsilateral breast tumor recurrence or new ipsilateral primary tumor. Tracer uptake was used to identify and isolate the sentinel lymph node during surgery, and it was classified after staining with hematoxylin and eosin and monoclonal anti-cytokeratin antibodies. Aside from negative predictive value, overall accuracy and false-negative rate of repeat sentinel lymph node biopsy were assessed. A multicenter, prospective study was conducted performing 30 repeat sentinel lymph node biopsy completed by back-up axillary lymph node dissection for ipsilateral breast tumor recurrence or new ipsilateral primary tumor in patients formerly treated with previous breast conservative surgery and negative sentinel lymph node biopsy. Negative predictive value, overall accuracy and false-negative rate of repeat sentinel lymph node biopsy were assessed. Sentinel lymph nodes were mapped in 27 patients out of 30 (90%). Aberrant drainage pathways were observed in one patient (3.7%). Tracer uptake was sufficient to identify and isolate the sentinel lymph node during surgery in 23 cases (76.6%); the patients in whom lymphoscintigraphy failed or no sentinel lymph nodes could be isolated underwent axillary lymph node dissection. The negative predictive value was 95.2%, the accuracy was 95.6% and the false-negative rate was 33%. Repeat sentinel lymph node biopsy is feasible and accurate, with a high negative predictive value. Patients with ipsilateral breast tumor recurrence or new ipsilateral primary tumor after previous breast conservative surgery and negative sentinel lymph node biopsy can be treated with repeat sentinel lymph node biopsy for the axillary staging and can be spared axillary dissection in case of absence of metastases. However, repeat sentinel lymph node biopsy may prove technically impracticable in about one quarter of cases and thus axillary lymph node dissection remains the only viable option in such instance.
True detection limits in an experimental linearly heteroscedastic system.. Part 2
NASA Astrophysics Data System (ADS)
Voigtman, Edward; Abraham, Kevin T.
2011-11-01
Despite much different processing of the experimental fluorescence detection data presented in Part 1, essentially the same estimates were obtained for the true theoretical Currie decision levels ( YC and XC) and true Currie detection limits ( YD and XD). The obtained experimental values, for 5% probability of false positives and 5% probability of false negatives, were YC = 56.0 mV, YD = 125. mV, XC = 0.132 μg/mL and XD = 0.293 μg/mL. For 5% probability of false positives and 1% probability of false negatives, the obtained detection limits were YD = 158 . mV and XD = 0.371 μg/mL. Furthermore, by using bootstrapping methodology on the experimental data for the standards and the analytical blank, it was possible to validate previously published experimental domain expressions for the decision levels ( yC and xC) and detection limits ( yD and xD). This was demonstrated by testing the generated decision levels and detection limits for their performance in regard to false positives and false negatives. In every case, the obtained numbers of false negatives and false positives were as specified a priori.
Intellectual factors in false memories of patients with schizophrenia.
Zhu, Bi; Chen, Chuansheng; Loftus, Elizabeth F; Dong, Qi; Lin, Chongde; Li, Jun
2018-07-01
The current study explored the intellectual factors in false memories of 139 patients with schizophrenia, using a recognition task and an IQ test. The full-scale IQ score of the participants ranged from 57 to 144 (M = 100, SD = 14). The full IQ score had a negative correlation with false recognition in patients with schizophrenia, and positive correlations with high-confidence true recognition and discrimination rates. Further analyses with the subtests' scores revealed that false recognition was negatively correlated with scores of performance IQ (and one of its subtests: picture arrangement), whereas true recognition was positively correlated with scores of verbal IQ (and two of its subtests: information and digit span). High-IQ patients had less false recognition (overall or high-confidence false recognition), more high-confidence true recognition, and higher discrimination abilities than those with low IQ. These findings contribute to a better understanding of the cognitive mechanism in false memory of patients with schizophrenia, and are of practical relevance to the evaluation of memory reliability in patients with different intellectual levels. Copyright © 2018 Elsevier B.V. All rights reserved.
Moatamed, Neda A; Naini, Bita V; Fathizadeh, Payman; Estrella, Julie; Apple, Sophia K
2009-10-01
The clinical diagnosis of a mass in the neck region encompasses a wide spectrum of differential diagnosis. Fine-needle aspiration is a quick and safe technique, which can provide useful information for initial assessment and further therapeutic measures. The aim of this retrospective study was to evaluate the performance characteristics of the fine-needle aspiration (FNA) in cystic neck lesions. Of 142 patients with FNA for cystic neck masses during 2002-2007, 92 cases were selected with a follow-up histologic diagnosis, excluding the cystic colloid nodule of the thyroid. The cases were divided into salivary gland cystic neck (37 patients) and non-salivary cystic neck (55 patients) mass groups. False-positive and false-negative diagnoses were applied only to the malignant lesions after confirmation by histopathology. In the first group, nine malignant and 28 benign diagnoses were made by FNA; of which three were false-negative. In the second group, there were nine malignant and 46 benign diagnoses with three false negatives. The overall performance of the FNA showed 76% sensitivity and 100% specificity. In conclusion, FNA of the cystic neck lesions offers an invaluable and highly specific initial diagnostic approach for the management of the patients. (c) 2009 Wiley-Liss, Inc.
Lin, Karl K; Rahman, Mohammad A
2018-05-21
Interest has been expressed in using a joint test procedure that requires that the results of both a trend test and a pairwise comparison test between the control and the high groups be statistically significant simultaneously at the levels of significance recommended in the FDA 2001 draft guidance for industry document for the separate tests in order for the drug effect on the development of an individual tumor type to be considered as statistically significant. Results of our simulation studies show that there is a serious consequence of large inflations of the false negative rate through large decreases of false positive rate in the use of the above joint test procedure in the final interpretation of the carcinogenicity potential of a new drug if the levels of significance recommended for separate tests are used. The inflation can be as high as 204.5% of the false negative rate when the trend test alone is required to test if the effect is statistically significant. To correct the problem, new sets of levels of significance have also been developed for those who want to use the joint test in reviews of carcinogenicity studies.
Fehr, Mathias K
2011-10-01
Sentinel lymph node (SLN) dissections have been shown to be sensitive for the evaluation of nodal basins for metastatic disease and are associated with decreased short-term and long-term morbidity when compared with complete lymph node dissection. There has been increasing interest in the use of SLN technology in gynecologic cancers. This review assesses the current evidence-based literature for the use of SLN dissections in gynecologic malignancies. Recent literature continues to support the safety and feasibility of SLN biopsy for early stage vulvar cancer with negative predictive value approaching 100 % and low false negative rates. Alternatively, for endometrial cancer most studies have reported low false-negative rates, with variable sensitivities and have reported low detection rates of the sentinel node. Studies examining the utility of SLN biopsy in early-stage cervical cancer remain promising with detection rates, sensitivities, and false-negative rates greater than 90 % for stage 1B1 tumors. SLN dissections have been shown to be effective and safe in certain, select vulvar cancer patients and can be considered an alternative surgical approach for these patients. For endometrial and cervical cancer, SLN dissection continues to have encouraging results and however needs further investigation.
Iverson, Grant L; Langlois, Jean A; McCrea, Michael A; Kelly, James P
2009-11-01
There is ongoing debate regarding the epidemiology of mild traumatic brain injury (MTBI) in military personnel. Accurate and timely estimates of the incidence of brain injury and the prevalence of long-term problems associated with brain injuries among active duty service members and veterans are essential for (a) operational planning, and (b) to allocate sufficient resources for rehabilitation and ongoing services and supports. The purpose of this article is to discuss challenges associated with post-deployment screening for MTBI. Multiple screening methods have been used in military, Veterans Affairs, and independent studies, which complicate cross-study comparisons of the resulting epidemiological data. We believe that post-deployment screening is important and necessary--but no screening methodology will be flawless, and false positives and false negatives are inevitable. Additional research is necessary to refine the sequential screening methodology, with the goal of minimizing false negatives during initial post-deployment screening and minimizing false positives during follow-up evaluations.
Mood-congruent memory in depression - the influence of personal relevance and emotional context.
Wittekind, Charlotte E; Terfehr, Kirsten; Otte, Christian; Jelinek, Lena; Hinkelmann, Kim; Moritz, Steffen
2014-03-30
The investigation of veridical mood-congruent memory (MCM) in major depressive disorder (MDD) has been subject of many studies, whereas mood-congruent false memory has received comparatively little attention. The present study examined the influence of valence, personal relevance and the valence of the context of the learning material on true and false MCM in 20 inpatients with MDD and 20 healthy controls. Sixty positive, negative, neutral or personally relevant nouns were either combined with a positive, negative or neutral adjective. Word pairs were presented to participants in a learning trial. In a recognition task, participants had to identify the previously studied word pairs. A MCM effect could not be found for hits. However, in exploratory analyses, word pairs containing personally relevant nouns were more rated towards old by the patient relative to the control group. Furthermore, depressed patients tended to rate items more towards old than controls when the words were presented in a negative new context. Results are in line with previous findings in depression research emphasizing the role of mood-congruent false memories for mood disorders. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
The semantics of emotion in false memory.
Brainerd, C J; Bookbinder, S H
2018-03-26
The emotional valence of target information has been a centerpiece of recent false memory research, but in most experiments, it has been confounded with emotional arousal. We sought to clarify the results of such research by identifying a shared mathematical relation between valence and arousal ratings in commonly administered normed materials. That relation was then used to (a) decide whether arousal as well as valence influences false memory when they are confounded and to (b) determine whether semantic properties that are known to affect false memory covary with valence and arousal ratings. In Study 1, we identified a quadratic relation between valence and arousal ratings of words and pictures that has 2 key properties: Arousal increases more rapidly as function of negative valence than positive valence, and hence, a given level of negative valence is more arousing than the same level of positive valence. This quadratic function predicts that if arousal as well as valence affects false memory when they are confounded, false memory data must have certain fine-grained properties. In Study 2, those properties were absent from norming data for the Cornell-Cortland Emotional Word Lists, indicating that valence but not arousal affects false memory in those norms. In Study 3, we tested fuzzy-trace theory's explanation of that pattern: that valence ratings are positively related to semantic properties that are known to increase false memory, but arousal ratings are not. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Effects of aging and education on false memory.
Lee, Yuh-Shiow; Lee, Chia-Lin; Yang, Hua-Te
2012-01-01
This study examined the effects of aging and education on participants' false memory for words that were not presented. Three age groups of participants with either a high or low education level were asked to study lists of semantically related words. Both age and education were found to affect veridical and false memory, as indicated in the recall and recognition of the studied word and nonstudied lures. A low education level had a negative effect on memory performance for both young and middle-aged adults. Older adults with a high level of education had a higher level of false memory than those with a lower education level. The results of this study are discussed in terms of the importance of education on false memory and mechanisms that create false memory of words in older adults.
Masking as an effective quality control method for next-generation sequencing data analysis.
Yun, Sajung; Yun, Sijung
2014-12-13
Next generation sequencing produces base calls with low quality scores that can affect the accuracy of identifying simple nucleotide variation calls, including single nucleotide polymorphisms and small insertions and deletions. Here we compare the effectiveness of two data preprocessing methods, masking and trimming, and the accuracy of simple nucleotide variation calls on whole-genome sequence data from Caenorhabditis elegans. Masking substitutes low quality base calls with 'N's (undetermined bases), whereas trimming removes low quality bases that results in a shorter read lengths. We demonstrate that masking is more effective than trimming in reducing the false-positive rate in single nucleotide polymorphism (SNP) calling. However, both of the preprocessing methods did not affect the false-negative rate in SNP calling with statistical significance compared to the data analysis without preprocessing. False-positive rate and false-negative rate for small insertions and deletions did not show differences between masking and trimming. We recommend masking over trimming as a more effective preprocessing method for next generation sequencing data analysis since masking reduces the false-positive rate in SNP calling without sacrificing the false-negative rate although trimming is more commonly used currently in the field. The perl script for masking is available at http://code.google.com/p/subn/. The sequencing data used in the study were deposited in the Sequence Read Archive (SRX450968 and SRX451773).
A statistical model of false negative and false positive detection of phase singularities.
Jacquemet, Vincent
2017-10-01
The complexity of cardiac fibrillation dynamics can be assessed by analyzing the distribution of phase singularities (PSs) observed using mapping systems. Interelectrode distance, however, limits the accuracy of PS detection. To investigate in a theoretical framework the PS false negative and false positive rates in relation to the characteristics of the mapping system and fibrillation dynamics, we propose a statistical model of phase maps with controllable number and locations of PSs. In this model, phase maps are generated from randomly distributed PSs with physiologically-plausible directions of rotation. Noise and distortion of the phase are added. PSs are detected using topological charge contour integrals on regular grids of varying resolutions. Over 100 × 10 6 realizations of the random field process are used to estimate average false negative and false positive rates using a Monte-Carlo approach. The false detection rates are shown to depend on the average distance between neighboring PSs expressed in units of interelectrode distance, following approximately a power law with exponents in the range of 1.14 to 2 for false negatives and around 2.8 for false positives. In the presence of noise or distortion of phase, false detection rates at high resolution tend to a non-zero noise-dependent lower bound. This model provides an easy-to-implement tool for benchmarking PS detection algorithms over a broad range of configurations with multiple PSs.
ERIC Educational Resources Information Center
Rohrer, Lisa M.; Cicchetti, Dante; Rogosch, Fred A.; Toth, Sheree L.; Maughan, Angeline
2011-01-01
Research has shown that children of depressed mothers are at risk for problems in a variety of developmental domains; however, little is known about the effects of maternal depression on children's emerging understanding of false beliefs. In this study, 3 false belief tasks were administered to 5-year-old children whose mothers had either met…
Sherlock Holmes and child psychopathology assessment approaches: the case of the false-positive.
Jensen, P S; Watanabe, H
1999-02-01
To explore the relative value of various methods of assessing childhood psychopathology, the authors compared 4 groups of children: those who met criteria for one or more DSM diagnoses and scored high on parent symptom checklists, those who met psychopathology criteria on either one of these two assessment approaches alone, and those who met no psychopathology assessment criterion. Parents of 201 children completed the Child Behavior Checklist (CBCL), after which children and parents were administered the Diagnostic Interview Schedule for Children (version 2.1). Children and parents also completed other survey measures and symptom report inventories. The 4 groups of children were compared against "external validators" to examine the merits of "false-positive" and "false-negative" cases. True-positive cases (those that met DSM criteria and scored high on the CBCL) differed significantly from the true-negative cases on most external validators. "False-positive" and "false-negative" cases had intermediate levels of most risk factors and external validators. "False-positive" cases were not normal per se because they scored significantly above the true-negative group on a number of risk factors and external validators. A similar but less marked pattern was noted for "false-negatives." Findings call into question whether cases with high symptom checklist scores despite no formal diagnoses should be considered "false-positive." Pending the availability of robust markers for mental illness, researchers and clinicians must resist the tendency to reify diagnostic categories or to engage in arcane debates about the superiority of one assessment approach over another.
Taylor, Michelle; Sullivan, John; Ring, Susan M; Macleod, John; Hickman, Matthew
2017-03-01
We investigate the extent of and factors associated with denial of previously reported cannabis and other illicit drug use, and assess the potential of hair testing for measuring substance use in general population samples. Birth cohort study. United Kingdom, 1991-present. A total of 3643 participants who provided hair and self-report measures of cannabis and other illicit drug use in the Avon Longitudinal Study of Parents and Children (ALSPAC) at age 18 years. Denial of ever use of cannabis and other illicit drugs at age 18 following previously reported use. Positive hair drug tests for cannabis and other illicit drugs, and expected numbers of false positives and false negatives based on expected sensitivity and specificity. Cannabis and other illicit drug use was reported by 1223 and 393 individuals, respectively, before age 18 years. Of these 176 (14.4%) and 99 (25.2%), respectively, denied use at age 18. Denial of cannabis use decreased with the reporting of other substances and antisocial behaviour. Cannabis and other illicit drug use at age 18 was reported by 547 (22.5%) and 203 (8.4%) individuals, respectively. Of these, 111 (20.3%) and 13 (6.4%) were hair-positive for cannabis and other illicit drugs, respectively. Based on hair testing for cannabis use we expect 0 [95% confidence interval (CI) = 0-169] false positives and 394 (95% CI = 323-449) false negatives compared to observed 362 potential false positives and 436 potential false negatives based on self-report. In hair-positive individuals, reporting the use of other substances and antisocial behaviour decreased the odds of a negative self-report. Hair analysis provides an unreliable marker of substance use in general population samples. People who report more frequent substance use before age 18 are less likely to later deny previous substance use at age 18 than people who report occasional use. © 2016 The Authors. Addiction published by John Wiley & Sons Ltd on behalf of Society for the Study of Addiction.
Where Have All the Interactions Gone? Estimating the Coverage of Two-Hybrid Protein Interaction Maps
Huang, Hailiang; Jedynak, Bruno M; Bader, Joel S
2007-01-01
Yeast two-hybrid screens are an important method for mapping pairwise physical interactions between proteins. The fraction of interactions detected in independent screens can be very small, and an outstanding challenge is to determine the reason for the low overlap. Low overlap can arise from either a high false-discovery rate (interaction sets have low overlap because each set is contaminated by a large number of stochastic false-positive interactions) or a high false-negative rate (interaction sets have low overlap because each misses many true interactions). We extend capture–recapture theory to provide the first unified model for false-positive and false-negative rates for two-hybrid screens. Analysis of yeast, worm, and fly data indicates that 25% to 45% of the reported interactions are likely false positives. Membrane proteins have higher false-discovery rates on average, and signal transduction proteins have lower rates. The overall false-negative rate ranges from 75% for worm to 90% for fly, which arises from a roughly 50% false-negative rate due to statistical undersampling and a 55% to 85% false-negative rate due to proteins that appear to be systematically lost from the assays. Finally, statistical model selection conclusively rejects the Erdös-Rényi network model in favor of the power law model for yeast and the truncated power law for worm and fly degree distributions. Much as genome sequencing coverage estimates were essential for planning the human genome sequencing project, the coverage estimates developed here will be valuable for guiding future proteomic screens. All software and datasets are available in Datasets S1 and S2, Figures S1–S5, and Tables S1−S6, and are also available from our Web site, http://www.baderzone.org. PMID:18039026
Wu, Shan; Zhang, Xiaofeng; Shuai, Jiangbing; Li, Ke; Yu, Huizhen; Jin, Chenchen
2016-07-04
To simplify the PNA-FISH (Peptide nucleic acid-fluorescence in situ hybridization) test, molecular beacon based PNA probe combined with fluorescence scanning detection technology was applied to replace the original microscope observation to detect Listeria monocytogenes The 5′ end and 3′ end of the L. monocytogenes specific PNA probes were labeled with the fluorescent group and the quenching group respectively, to form a molecular beacon based PNA probe. When PNA probe used for fluorescence scanning and N1 treatment as the control, the false positive rate was 11.4%, and the false negative rate was 0; when N2 treatment as the control, the false positive rate decreased to 4.3%, but the false negative rate rose to 18.6%. When beacon based PNA probe used for fluorescence scanning, taken N1 treatment as blank control, the false positive rate was 8.6%, and the false negative rate was 1.4%; taken N2 treatment as blank control, the false positive rate was 5.7%, and the false negative rate was 1.4%. Compared with PNA probe, molecular beacon based PNA probe can effectively reduce false positives and false negatives. The success rates of hybridization of the two PNA probes were 83.3% and 95.2% respectively; and the rates of the two beacon based PNA probes were 91.7% and 90.5% respectively, which indicated that labeling the both ends of the PNA probe dose not decrease the hybridization rate with the target bacteria. The combination of liquid phase PNA-FISH and fluorescence scanning method, can significantly improve the detection efficiency.
Missed Lesions at CT Colonography: Lessons Learned
Pickhardt, Perry J.
2017-01-01
Misinterpretation at CT colonography (CTC) can result in either a colorectal lesion being missed (false negative) or a false-positive diagnosis. This review will largely focus on potential missed lesions – and ways to avoid such misses. The general causes of false-negative interpretation at CTC can be broadly characterized and grouped into discrete categories related to suboptimal study technique, specific lesion characteristics, anatomic location, and imaging artifacts. Overlapping causes further increase the likelihood of missing a clinically relevant lesion. In the end, if the technical factors of bowel preparation, colonic distention, and robust CTC software are adequately addressed on a consistent basis, and the reader is aware of all the potential pitfalls at CTC, important lesions will seldom be missed. PMID:22539045
There was not, they did not: May negation cause the negated ideas to be remembered as existing?
2017-01-01
In this article we demonstrate that negation of ideas can have paradoxical effects, possibly leading the listener to believe that the negated ideas actually existed. In Experiment 1, participants listened to a description of a house, in which some objects were mentioned, some were negated, and some were not mentioned at all. When questioned about the existence of these objects a week later, the participants gave more false positives for items that were negated in the original material than for items that were not mentioned at all, an effect we call negation related false memories (NRFM). The NRFM effect was replicated again in Experiment 2 with a sample of five and six year-old children. Experiment 3 confirmed NRFM in the case of negated actions. The results are discussed in terms of retention hypothesis, as well as the theory that negation can activate a representation of an entity and behaviour. It is also indicated that future research is needed to ensure that it is indeed negation which caused false alarms, not merely mentioning an object. PMID:28448549
Comparison of the diuretic renogram and the pressure perfusion study in children
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kass, E.J.; Majd, M.; Belman, A.B.
1985-07-01
The authors evaluated 42 hydronephrotic kidneys with diuretic renography and pressure perfusion studies to diagnose or exclude the presence of obstruction. Both studies were highly accurate but a small number of false positive and false negative studies were observed with each testing modality. The advantages, disadvantages and potential sources of inaccuracy of each study are discussed, and a protocol for the evaluation of hydronephrosis incorporating both studies is proposed.
Facebook False Self-Presentation Behaviors and Negative Mental Health.
Wright, Elizabeth J; White, Katherine M; Obst, Patricia L
2018-01-01
As research examining what constitutes Facebook false self-presentation is lacking, the aim of this study was to develop a preliminary inventory of Facebook false self-presentation behaviors, as well as identify predictors and possible outcomes. Participants (N = 211) completed questions regarding frequency of engagement in Facebook false self-presentation behaviors, as well as self-esteem, social influences, motivation strategies, well-being, depression, anxiety, and stress. Results indicated the presence of two distinct false self-presentation behaviors: lying (e.g., untruthful status updates, profile creation) and liking behaviors (e.g., liking posts dishonestly), each associated with different predictors and outcomes. Results indicated that moral norms significantly predicted lying behaviors; and age, self-esteem, group norms, and moral norms significantly predicted liking behaviors. Unexpectedly, liking behaviors were associated with depression, anxiety, and stress, whereas lying behaviors were related to anxiety only. Findings highlight associations between online self-presentation strategies, in particular liking behaviors, on Facebook and possible offline negative mental health.
The Development of Theory of Mind and Positive and Negative Reciprocity in Preschool Children
Schug, Joanna; Takagishi, Haruto; Benech, Catalina; Okada, Hiroyuki
2016-01-01
This study examined the relation between the acquisition of false-beliefs theory of mind (ToM) and reciprocity in preschoolers. Preschool-aged children completed a task assessing the understanding of false beliefs, and played an Ultimatum Game (UG) with another child in a face-to-face setting. Negative reciprocity was assessed by examining the rejection of unfair offers made by another child in the UG, while positive reciprocity was assessed by examining allocations made by participants in a Dictator Game (DG) following the UG. The results indicated that children who had passed a task assessing first-order false beliefs were more likely to make generous offers in a DG following a fair offer made by their partner in a proceeding UG, but that false beliefs ToM was unrelated to the rejection of unfair offers in the UG. PMID:27445881
The Development of Theory of Mind and Positive and Negative Reciprocity in Preschool Children.
Schug, Joanna; Takagishi, Haruto; Benech, Catalina; Okada, Hiroyuki
2016-01-01
This study examined the relation between the acquisition of false-beliefs theory of mind (ToM) and reciprocity in preschoolers. Preschool-aged children completed a task assessing the understanding of false beliefs, and played an Ultimatum Game (UG) with another child in a face-to-face setting. Negative reciprocity was assessed by examining the rejection of unfair offers made by another child in the UG, while positive reciprocity was assessed by examining allocations made by participants in a Dictator Game (DG) following the UG. The results indicated that children who had passed a task assessing first-order false beliefs were more likely to make generous offers in a DG following a fair offer made by their partner in a proceeding UG, but that false beliefs ToM was unrelated to the rejection of unfair offers in the UG.
Rohrer, Lisa M; Cicchetti, Dante; Rogosch, Fred A; Toth, Sheree L; Maughan, Angeline
2011-01-01
Research has shown that children of depressed mothers are at risk for problems in a variety of developmental domains; however, little is known about the effects of maternal depression on children's emerging understanding of false beliefs. In this study, 3 false belief tasks were administered to 5-year-old children whose mothers had either met criteria for major depressive disorder within the first 20 months of the child's life (n = 91) or had never been depressed (n = 50). Significant difficulties in performance were found among the children of depressed mothers, especially those whose mothers had experienced early and recent recurrent depressive disorder. Regardless of diagnostic status, children whose mothers exhibited negativity during problem-solving tasks administered at an earlier developmental period also were less likely to demonstrate false belief understanding. These effects remained even after child verbal ability was controlled.
Rohrer, Lisa M.; Cicchetti, Dante; Rogosch, Fred A.; Toth, Sheree L.; Maughan, Angeline
2015-01-01
Research has shown that children of depressed mothers are at risk for problems in a variety of developmental domains; however, little is known about the effects of maternal depression on children’s emerging understanding of false beliefs. In this study, three false belief tasks were administered to five-year-old children whose mothers had either met criteria for major depressive disorder within the first 20 months of the child’s life (n = 91) or had never been depressed (n = 50). Significant difficulties in performance were found among the children of depressed mothers, especially those whose mothers had experienced early and recent recurrent depressive disorder. Regardless of diagnostic status, children whose mothers exhibited negativity during problem-solving tasks administered at an earlier developmental period also were less likely to demonstrate false belief understanding. These effects remained even after child verbal ability was controlled. PMID:21244156
Zhang, Jingyang; Chaloner, Kathryn; McLinden, James H.; Stapleton, Jack T.
2013-01-01
Reconciling two quantitative ELISA tests for an antibody to an RNA virus, in a situation without a gold standard and where false negatives may occur, is the motivation for this work. False negatives occur when access of the antibody to the binding site is blocked. Based on the mechanism of the assay, a mixture of four bivariate normal distributions is proposed with the mixture probabilities depending on a two-stage latent variable model including the prevalence of the antibody in the population and the probabilities of blocking on each test. There is prior information on the prevalence of the antibody, and also on the probability of false negatives, and so a Bayesian analysis is used. The dependence between the two tests is modeled to be consistent with the biological mechanism. Bayesian decision theory is utilized for classification. The proposed method is applied to the motivating data set to classify the data into two groups: those with and those without the antibody. Simulation studies describe the properties of the estimation and the classification. Sensitivity to the choice of the prior distribution is also addressed by simulation. The same model with two levels of latent variables is applicable in other testing procedures such as quantitative polymerase chain reaction tests where false negatives occur when there is a mutation in the primer sequence. PMID:23592433
Detection of CIN by naked eye visualization after application of acetic acid.
Londhe, M; George, S S; Seshadri, L
1997-06-01
A prospective study was undertaken to determine the sensitivity and specificity of acetic application to the cervix followed by naked eye visualization as a screening test for detection of cervical intraepithelial neoplasia. Three hundred and seventy two sexually active woman in the reproductive age group were studied. All the women underwent Papanicolaou test, acetic acid test and colposcopy. One hundred and seventy five woman were acetic acid test negative, 197 women were acetic acid test positive. The sensitivity of acetic acid test was 72.4%, specificity 54% and false negative rate 15.2%, as compared to papanicolaou test which had a sensitivity of 13.2%, specificity of 96.3% and false negative rate of 24.4%. The advantage of the acetic acid test lies in its easy technique, low cost and high sensitivity which are important factors for determining the efficacy of any screening programme in developing countries.
Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?
Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M. Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz
2015-01-01
Background Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Methodology/Principal Findings Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). Conclusion The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study. PMID:26161864
Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?
Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz
2015-01-01
Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.
Sadder and less accurate? False memory for negative material in depression.
Joormann, Jutta; Teachman, Bethany A; Gotlib, Ian H
2009-05-01
Previous research has demonstrated that induced sad mood is associated with increased accuracy of recall in certain memory tasks; the effects of clinical depression, however, are likely to be quite different. The authors used the Deese-Roediger-McDermott paradigm to examine the impact of clinical depression on erroneous recall of neutral and/or emotional stimuli. Specifically, they presented Deese-Roediger-McDermott lists that were highly associated with negative, neutral, or positive lures and compared participants diagnosed with major depressive disorder and nondepressed control participants on the accuracy of their recall of presented material and their false recall of never-presented lures. Compared with control participants, major depressive disorder participants recalled fewer words that had been previously presented but were more likely to falsely recall negative lures; there were no differences between major depressive disorder and control participants in false recall of positive or neutral lures. These findings indicate that depression is associated with false memories of negative material.
Rahal, M; Kervaire, B; Villard, J; Tiercy, J-M
2008-03-01
Human leukocyte antigen (HLA) typing by polymerase chain reaction-sequence-specific oligonucleotide (PCR-SSO) hybridization on solid phase (microbead assay) or polymerase chain reaction-sequence-specific primers (PCR-SSP) requires interpretation softwares to detect all possible allele combinations. These programs propose allele calls by taking into account false-positive or false-negative signal(s). The laboratory has the option to validate typing results in the presence of strongly cross-reacting or apparent false-negative signals. Alternatively, these seemingly aberrant signals may disclose novel variants. We report here four new HLA-B (B*5620 and B*5716) and HLA-DRB1 alleles (DRB1*110107 and DRB1*1474) that were detected by apparent false-negative or -positive hybridization or amplification patterns, and ultimately resolved by sequencing. To avoid allele misassignments, a comprehensive evaluation of acquired data as documented in a quality assurance system is therefore required to confirm unambiguous typing interpretation.
Won, Kyu-Hee; Lee, Jae Yeon; Cho, Hye-Yon; Suh, Dong Hoon; No, Jae Hong; Kim, Yong-Beom
2015-03-01
Human papillomavirus (HPV) test was incorporated into the triage of lesser abnormal cervical cytologies: atypical squamous cells of undetermined significance (ASCUS) or low-grade squamous intraepithelial lesion (LSIL). This study aimed to evaluate the impact of age on the efficacy of HPV testing in patients with lesser abnormal cervical cytologies. A total of 439 patients with ASCUS or LSIL were included. The association between age groups and the diagnostic performances of HPV test for high-grade cervical intraepithelial neoplasia (CIN2+) was evaluated. Median age was 44 years (range, 17 to 75 years). ASCUS was more frequently observed in older patients while LSIL was more common in younger patients (P=0.002). CIN2+ was found in 11.3% (32/284) of the ASCUS patients and 12.9% (20/155) of patients with LSIL. Older patients with ASCUS showed lower HPV infection rates (P=0.025), but not LSIL (P=0.114). However, the prevalence of CIN2+ was similar between the age groups with ASCUS or LSIL. In patients with ASCUS, the false negative rate of HPV test for CIN2+ was 6.2%. The false negative rate of the HPV test became higher with increasing of the age after the age of 50 (P=0.034). Our findings suggest that false negative rate of the HPV test for CIN2+ in ASCUS patients older than 50 years might become higher with increasing of the age. Negative HPV results in patients of the age >50 years with ASCUS should be carefully interpreted.
Noninvasive Electromagnetic Detection of Bladder Cancer
Cormio, Luigi; Vedruccio, Clarbruno; Leucci, Giorgio; Massenio, Paolo; Di Fino, Giuseppe; Cavaliere, Vincenzo; Carrieri, Giuseppe
2014-01-01
Objectives. Normal and neoplastic human tissues have different electromagnetic properties. This study aimed to determine the diagnostic accuracy of noninvasive electromagnetic detection of bladder cancer (BC) by the tissue-resonance interaction method (TRIM-prob). Patients and Methods. Consecutive patients were referred for cystoscopy because of (i) microscopic or gross hematuria and/or irritative voiding symptoms and (ii) bladder ultrasounds and urinary cytology findings negative or just suspicious of malignancy. Patients were first submitted to TRIM-prob bladder scanning by a single investigator and then to cystoscopy by another investigator blind to TRIM-prob data. Results. In 125 evaluated patients cystoscopy was positive for BC in 47 and negative in the remaining 78; conversely, TRIM-prob bladder scanning was positive for BC in 53 and negative in 72. In particular, TRIM-prob scanning yielded 7 false positives and only one false negative; therefore, its overall sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.9%, 89.9%, 86.8%, 98.6%, and 93.6%, respectively. Conclusions. TRIM-prob bladder scanning was a simple and quite accurate method for non-invasive electromagnetic detection of BC. If the elevated positive and negative predictive values will be replicated in further well-designed studies, it could be used to screen asymptomatic patients at high risk of BC. PMID:24563795
Introducing Bayesian thinking to high-throughput screening for false-negative rate estimation.
Wei, Xin; Gao, Lin; Zhang, Xiaolei; Qian, Hong; Rowan, Karen; Mark, David; Peng, Zhengwei; Huang, Kuo-Sen
2013-10-01
High-throughput screening (HTS) has been widely used to identify active compounds (hits) that bind to biological targets. Because of cost concerns, the comprehensive screening of millions of compounds is typically conducted without replication. Real hits that fail to exhibit measurable activity in the primary screen due to random experimental errors will be lost as false-negatives. Conceivably, the projected false-negative rate is a parameter that reflects screening quality. Furthermore, it can be used to guide the selection of optimal numbers of compounds for hit confirmation. Therefore, a method that predicts false-negative rates from the primary screening data is extremely valuable. In this article, we describe the implementation of a pilot screen on a representative fraction (1%) of the screening library in order to obtain information about assay variability as well as a preliminary hit activity distribution profile. Using this training data set, we then developed an algorithm based on Bayesian logic and Monte Carlo simulation to estimate the number of true active compounds and potential missed hits from the full library screen. We have applied this strategy to five screening projects. The results demonstrate that this method produces useful predictions on the numbers of false negatives.
García-Garzon, J R; Villasboas-Rosciolesi, Diego; Baquero, Miguel; Bassa, Pere; Soler, Marina; Riera, Eduard
2016-08-01
We report a case of a 44-year-old man with neurological symptoms and MRI findings, which were unable to differentiate between glioma and lymphoma. Metabolic characterization by means of PET imaging with F-FDG and C-methionine is proposed to determine the benign or tumor (high- and low-grade) origin of brain lesions. In this case, the MRI lesion corresponded with an inconclusive metabolic pattern of intense F-FDG uptake and no significant C-methionine uptake. Pathological study revealed a false-negative case of C-methionine due to lymphoma.
Kumar, Navin; Pande, Veena; Bhatt, R M; Shah, Naman K; Mishra, Neelima; Srivastava, Bina; Valecha, Neena; Anvikar, Anupkumar R
2013-01-01
Genetic polymorphisms in diagnostic antigens are important factors responsible for variable performance of rapid diagnostic tests. Additionally, the failure of antigen expression due to gene deletion may also contribute to variable performance. We report Indian Plasmodium falciparum field isolates lacking both Pfhrp2 and Pfhrp3 genes leading to false negative results of rapid diagnostic tests. The study highlights need to determine the prevalence of P. falciparum isolates lacking these genes in larger field populations in India. Copyright © 2012 Elsevier B.V. All rights reserved.
Wilson, Mathew G; Lane, Andy M; Beedie, Chris J; Farooq, Abdulaziz
2012-01-01
The objective of the study is to examine the impact of accurate and inaccurate 'split-time' feedback upon a 10-mile time trial (TT) performance and to quantify power output into a practically meaningful unit of variation. Seven well-trained cyclists completed four randomised bouts of a 10-mile TT on a SRM™ cycle ergometer. TTs were performed with (1) accurate performance feedback, (2) without performance feedback, (3) and (4) false negative and false positive 'split-time' feedback showing performance 5% slower or 5% faster than actual performance. There were no significant differences in completion time, average power output, heart rate or blood lactate between the four feedback conditions. There were significantly lower (p < 0.001) average [Formula: see text] (ml min(-1)) and [Formula: see text] (l min(-1)) scores in the false positive (3,485 ± 596; 119 ± 33) and accurate (3,471 ± 513; 117 ± 22) feedback conditions compared to the false negative (3,753 ± 410; 127 ± 27) and blind (3,772 ± 378; 124 ± 21) feedback conditions. Cyclists spent a greater amount of time in a '20 watt zone' 10 W either side of average power in the negative feedback condition (fastest) than the accurate feedback (slowest) condition (39.3 vs. 32.2%, p < 0.05). There were no significant differences in the 10-mile TT performance time between accurate and inaccurate feedback conditions, despite significantly lower average [Formula: see text] and [Formula: see text] scores in the false positive and accurate feedback conditions. Additionally, cycling with a small variation in power output (10 W either side of average power) produced the fastest TT. Further psycho-physiological research should examine the mechanism(s) why lower [Formula: see text] and [Formula: see text] scores are observed when cycling in a false positive or accurate feedback condition compared to a false negative or blind feedback condition.
Kufa, Tendesayi; Lane, Tim; Manyuchi, Albert; Singh, Beverley; Isdahl, Zachary; Osmand, Thomas; Grasso, Mike; Struthers, Helen; McIntyre, James; Chipeta, Zawadi; Puren, Adrian
2017-01-01
Abstract We describe the accuracy of serial rapid HIV testing among men who have sex with men (MSM) in South Africa and discuss the implications for HIV testing and prevention. This was a cross-sectional survey conducted at five stand-alone facilities from five provinces. Demographic, behavioral, and clinical data were collected. Dried blood spots were obtained for HIV-related testing. Participants were offered rapid HIV testing using 2 rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using a third-generation enzyme immunoassay (EIA) and a fourth-generation EIA as confirmatory. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive, and false-negative rates were determined. Between August 2015 and July 2016, 2503 participants were enrolled. Of these, 2343 were tested by RDT on site with a further 2137 (91.2%) having definitive results on both RDT and EIA. Sensitivity, specificity, positive predictive value, negative predictive value, false-positive rates, and false-negative rates were 92.6% [95% confidence interval (95% CI) 89.6–94.8], 99.4% (95% CI 98.9–99.7), 97.4% (95% CI 95.2–98.6), 98.3% (95% CI 97.6–98.8), 0.6% (95% CI 0.3–1.1), and 7.4% (95% CI 5.2–10.4), respectively. False negatives were similar to true positives with respect to virological profiles. Overall accuracy of the RDT algorithm was high, but sensitivity was lower than expected. Post-HIV test counseling should include discussions of possible false-negative results and the need for retesting among HIV negatives. PMID:28700474
Causes of false-negative for high-grade urothelial carcinoma in urine cytology.
Lee, Paul J; Owens, Christopher L; Lithgow, Marie Y; Jiang, Zhong; Fischer, Andrew H
2016-12-01
The Paris System for classifying urine cytology emphasizes identification of high-grade urothelial carcinoma (HGUC). The causes of false-negative urine cytologies (UC) within this system are not well described. We identified 660 cases between 2005 and 2013 with both UC and subsequent cystoscopic biopsies. UC were classified as either Negative for HGUC or "Abnormal" ("Atypical", "Suspicious", and "Malignant"). Apparent false-negative cases were reviewed in a nonblinded fashion by two cytopathologists and two subspecialized genitourinary pathologists. A total of 199 of the 660 cases (30%) were histologically diagnosed as HGUC. The UC were "Abnormal" in 170/199 cases (sensitivity/specificity of 86%/71%). Twenty four apparent false negative cases were available for retrospective review. Five of 24 (21%) cystoscopic biopsies were found not to be HGUC on review (one false positive and four low-grade urothelial carcinoma (LGUC on review). Of the remaining 19 UC, 7 (29%) cytology samples were found to be truly negative on review, 11 (46%) were found to be Atypical, and 1 (4%) suspicious. Of the 12 UC that were at least "Atypical" with histologic HGUC on review: six misses (half) were attributed to obscuring inflammation/blood, four to poor preservation, eight to paucity of abnormal cells, and 1 case to interpretive error; many cases demonstrated overlapping reasons. About one fifth of apparent false negative diagnoses for HGUC can be because of overdiagnosis of HGUC by surgical pathologists. If poor preservation or obscured samples are called nondiagnostic, the sensitivity/specificity of UC for HGUC can be as high as 94%/71%. Diagn. Cytopathol. 2016;44:994-999. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Knobloch, O; Pelz, F; Wick, U; Nelson, D L; Zoll, B
1993-03-01
In order to test whether the direct molecular diagnostic approach for fragile X mental retardation (Martin-Bell syndrome, MBS) really makes diagnosis of this disease more precise, we evaluated the results of direct diagnosis in 40 German families at risk together with the results of an earlier study with closely linked flanking markers in the same families. Of 84 men analysed, 43 showed clinical signs. In 39 of these affected men the disease could be confirmed by direct diagnosis. Compared to cytogenetic data, one man was false negative and two were false positive. Two men, whose status could not be determined by means of RFLP data, proved to be normal transmitting males (NTMs). However, the possibility of being an NTM had to be rejected in one case on RFLP data. Fragile X syndrome could be confirmed in 10 of the 13 women with clinical signs. Compared to cytogenetic data there were three cases of false negative results and one of false positive. All 36 obligate carrier women were detected by the direct approach. In addition, 22 women were newly identified as normal transmitting females (NTFs), among them one woman who could not be identified by cytogenetic means or by analysis with closely linked markers. These findings are discussed in view of the relative reliability of the three diagnostic approaches to MBS. Special attention is drawn to the significance of false negative and false positive results in direct diagnosis.
The risk factor of false-negative and false-positive for T-SPOT.TB in active tuberculosis.
Di, Li; Li, Yan
2018-02-01
T-SPOT.TB is a promising diagnosis tool to identify both pulmonary tuberculosis and extrapulmonary tuberculosis, as well as latent tuberculosis; however, the factors that affect the results of T-SPOT.TB remains unclear. In this study, we aim to figure out the risk factor of T-SPOT.TB for active TB. A total of 349 patients were recruited between January 1st, 2016 and January 22st, 2017 at Renmin Hospital of Wuhan University, including 98 subjects with TB and 251 subjects with non-TB disease, and received T-SPOT.TB (Oxford Immunotec Ltd). Statistics were analyzed by SPSS 19.0 using logistic regression. The overall specificity and sensitivity of the T-SPOT.TB was 92.83% (233/251; 95%CI 0.8872-0.9557) and 83.67% (82/98; 95%CI 0.7454-0.9010), respectively. Patients with tuberculous meningitis were more likely to have false-negative results (OR 17.4, 95%CI 3.068-98.671; P<.001) while patients with cured TB tended to induce false-positive results (OR 30.297; 95%CI 7.069-129.849; P<.001). The results were not affected by sex, age, onset time, smoke, alcohol, treatment, allergic history, co-morbidity, TB (exclude tuberculous meningitis) (P>.05). Tuberculous meningitis was a risk factor of false-negative for T-SPOT.TB, while cured TB was a risk factor of false-positive. © 2017 Wiley Periodicals, Inc.
Griffey, Richard T; Trent, Caleb J; Bavolek, Rebecca A; Keeperman, Jacob B; Sampson, Christopher; Poirier, Robert F
2013-01-01
Failure to detect pregnancy in the emergency department (ED) can have important consequences. Urine human chorionic gonadotropin (uhCG) point-of-care (POC) assays are valued for rapidly detecting early pregnancy with high sensitivity. However, under certain conditions, POC uhCG tests can fail to detect pregnancy. In investigating a series of late first-trimester false-negative pregnancy tests in our ED, a novel and distinct causative phenomenon was recently elucidated in our institution. We discuss uhCG POC tests, review our false-negative rate, and describe mechanisms for false negatives and potential remedies. The false-negative POC uhCG rate is very low, but in the setting of a large volume of tests, the numbers are worth consideration. In positive uhCG POC tests, free and fixed antibodies bind hCG to form a "sandwich"; hCG is present in several variant forms that change in their concentrations at different stages of pregnancy. When in excess, intact hCG can saturate the antibodies, preventing sandwich formation (hook effect phenomenon). Some assays may include an antibody that does not recognize certain variants present in later stages of pregnancy. When this variant is in excess, it can bind one antibody avidly and the other not at all, resulting in a false-negative test (hook-like phenomenon). In both situations, dilution is key to an accurate test. Manufacturers should consider that uhCG tests are routinely used at many stages of pregnancy. Characterizing uhCG variants recognized by their tests and eliminating lot-to-lot variability may help improve uhCG test performance. Clinicians need to be aware of and familiarize themselves with the limitations of the specific type of uhCG POC tests used in their practice, recognizing that under certain circumstances, false-negative tests can occur. Copyright © 2013 Elsevier Inc. All rights reserved.
Robust Detection of Rare Species Using Environmental DNA: The Importance of Primer Specificity
Wilcox, Taylor M.; McKelvey, Kevin S.; Young, Michael K.; Jane, Stephen F.; Lowe, Winsor H.; Whiteley, Andrew R.; Schwartz, Michael K.
2013-01-01
Environmental DNA (eDNA) is being rapidly adopted as a tool to detect rare animals. Quantitative PCR (qPCR) using probe-based chemistries may represent a particularly powerful tool because of the method’s sensitivity, specificity, and potential to quantify target DNA. However, there has been little work understanding the performance of these assays in the presence of closely related, sympatric taxa. If related species cause any cross-amplification or interference, false positives and negatives may be generated. These errors can be disastrous if false positives lead to overestimate the abundance of an endangered species or if false negatives prevent detection of an invasive species. In this study we test factors that influence the specificity and sensitivity of TaqMan MGB assays using co-occurring, closely related brook trout (Salvelinus fontinalis) and bull trout (S. confluentus) as a case study. We found qPCR to be substantially more sensitive than traditional PCR, with a high probability of detection at concentrations as low as 0.5 target copies/µl. We also found that number and placement of base pair mismatches between the Taqman MGB assay and non-target templates was important to target specificity, and that specificity was most influenced by base pair mismatches in the primers, rather than in the probe. We found that insufficient specificity can result in both false positive and false negative results, particularly in the presence of abundant related species. Our results highlight the utility of qPCR as a highly sensitive eDNA tool, and underscore the importance of careful assay design. PMID:23555689
Robust detection of rare species using environmental DNA: the importance of primer specificity.
Wilcox, Taylor M; McKelvey, Kevin S; Young, Michael K; Jane, Stephen F; Lowe, Winsor H; Whiteley, Andrew R; Schwartz, Michael K
2013-01-01
Environmental DNA (eDNA) is being rapidly adopted as a tool to detect rare animals. Quantitative PCR (qPCR) using probe-based chemistries may represent a particularly powerful tool because of the method's sensitivity, specificity, and potential to quantify target DNA. However, there has been little work understanding the performance of these assays in the presence of closely related, sympatric taxa. If related species cause any cross-amplification or interference, false positives and negatives may be generated. These errors can be disastrous if false positives lead to overestimate the abundance of an endangered species or if false negatives prevent detection of an invasive species. In this study we test factors that influence the specificity and sensitivity of TaqMan MGB assays using co-occurring, closely related brook trout (Salvelinus fontinalis) and bull trout (S. confluentus) as a case study. We found qPCR to be substantially more sensitive than traditional PCR, with a high probability of detection at concentrations as low as 0.5 target copies/µl. We also found that number and placement of base pair mismatches between the Taqman MGB assay and non-target templates was important to target specificity, and that specificity was most influenced by base pair mismatches in the primers, rather than in the probe. We found that insufficient specificity can result in both false positive and false negative results, particularly in the presence of abundant related species. Our results highlight the utility of qPCR as a highly sensitive eDNA tool, and underscore the importance of careful assay design.
Breast cancer in tough economic times: disruptive technology emerging
NASA Astrophysics Data System (ADS)
Bretz, Phillip; Lynch, Richard
2012-06-01
The objective of this study was to investigate the efficacy of melding three emerging technologies: Pharmacogenomics, Modified Military Digital Infrared and Halo to establish their capability in diagnosing ultra-small breast cancers as well as other cancers. Mammography, ultrasound and MRI technologies have been available for over forty years, however, there is still no uniform utilization by women, costs continue to escalate and problems persist like high false positive rates for MRI and high false negative rates for mammography. Of the first 500 IR patients, 499 were female and 1 male. Of 550 OncoVue patients, 129 opted to undergo IR. A total of 19 were lost to follow-up. Patients who were negative on IR: 419/500 (84%). Of these, 63/419 went to biopsy because of findings of other diagnostic modalities. Of these 61/63 with negative IR had a negative biopsy. Of two missed, one was the fault of the investigator but was included. In this series 2/500 were false negative (0.4%). The sensitivity was 96% and the specificity was 79%. In total, 46 cancers were identified including five outside the breast (e.g. 2 lung cancers). A total of 92 MRIs were done and in 71/92 patients IR and MRI agreed. Using these three modalities the smallest cancer found was a 4 mm invasive cancer. The study demonstrated that these diagnostic techniques can dramatically lower cost and provide results at least as good as the older paradigms. Further research and a multicenter clinical trial are necessary to shift the paradigm of breast cancer diagnosis and treatment.
Tetteh, Ato Kwamena; Agyarko, Edward
2017-01-01
Screening results of 488 pregnant women aged 15-44 years whose blood samples had been tested on-site, using First Response® HIV 1/2, and confirmed with INNO-LIA™ HIV I/II Score were used. Of this total, 178 were reactive (HIV I, 154; HIV II, 2; and HIV I and HIV II, 22). Of the 154 HIV I-reactive samples, 104 were confirmed to be HIV I-positive and 2 were confirmed to be HIV II-positive, while 48 were confirmed to be negative [false positive rate = 17.44% (13.56-21.32)]. The two HIV II samples submitted were confirmed to be negative with the confirmatory test. For the 22 HIV I and HIV II samples, 7 were confirmed to be HIV I-positive and 1 was confirmed to be HIV I- and HIV II-positive, while 14 were confirmed to be negative. Of the 310 nonreactive samples, 6 were confirmed to be HIV I-positive and 1 was confirmed to be HIV II-positive [false negative rate = 5.79% (1.63-8.38)], while 303 were negative. False negative outcomes will remain unconfirmed, with no management options for the client. False negative rate of 5.79% requires attention, as its resultant implications on control of HIV/AIDS could be dire.
Lower Cutoffs for LC-MS/MS Urine Drug Testing Indicates Better Patient Compliance.
Krock, Kevin; Pesce, Amadeo; Ritz, Dennis; Thomas, Richard; Cua, Agnes; Rogers, Ryan; Lipnick, Phil; Kilbourn, Kristen
2017-11-01
Urine drug testing is used by health care providers to determine a patient's compliance to their prescribed regimen and to detect non-prescribed medications and illicit drugs. However, the cutoff levels used by clinical labs are often arbitrarily set and may not reflect the urine drug concentrations of compliant patients. Our aim was to test the hypothesis that commonly used cutoffs for many prescribed and illicit drugs were set too high, and methods using these cutoffs may yield a considerable number of false-negative results. The goals of this study were to outline the way to analyze patient results and estimate a more appropriate cutoff, develop and validate a high sensitivity analytical method capable of quantitating drugs and metabolites at lower than the commonly used cutoffs, and determine the number of true positive results that would have been missed when using the common cutoffs. This was a retrospective study of urine specimens submitted for urine drug testing as part of the monitoring of prescription drug compliance described in chronic opioid therapy treatment guidelines. The study was set in a clinical toxicology laboratory, using specimens submitted for routine analysis by health care providers in the normal course of business. Lognormal distributions of test results were generated and fitted with a trendline to estimate the required cutoff level necessary to capture the normal distributions of each drug for the patient population study. A validated laboratory derived liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis capable of achieving the required cutoff levels was developed for each drug and/or metabolite. The study shows that a lognormal distribution of patient urine test results fitted with a trendline is appropriate for estimating the required cutoff levels needed to assess medication adherence. The study showed a wide variation in the false-negative rate, ranging from 1.5% to 94.3% across a range of prescribed and illicit drugs. The patient specimens were largely sourced from patients in either a long-term pain management program or in treatment for substance use disorder in the US. These specimens may not be representative of patients in other types of treatment or in countries with different approaches to these issues. The high-sensitivity method reduces false-negative results which could negatively impact patient care. Clinicians using less sensitive methods for detecting and quantifying drugs and metabolites in urine should exercise caution in assessing patient adherence using and changing the treatment plan based on those results. Urine drug testing, patient adherence, clinical toxicology, immunoassay, LC-MS, definitive drug testing, REMS, negative test results, false negative.
False-positive cancer screens and health-related quality of life.
McGovern, Patricia M; Gross, Cynthia R; Krueger, Richard A; Engelhard, Deborah A; Cordes, Jill E; Church, Timothy R
2004-01-01
By design, screening tests are imperfect-unresponsive to some cancers (false negatives) while occasionally raising suspicion of cancer where none exists (false positives). This pilot study describes patients' responses to having a false-positive screening test for cancer, and identifies screening effects on health-related quality of life (HRQoL). The pilot findings suggest issues important for incorporation in future evaluations of the impact of screening for prostate, lung, colon, or ovarian (PLCO) cancers. Seven focus groups were conducted to identify the nature and meaning of all phases of PLCO screening. Minnesota participants in the Prostate, Lung, Colorectal and Ovarian Cancer Screening Trial who had completed screening, with at least 1 false-positive screen, participated (N = 47). Participants' reactions to abnormal screens and diagnostic work-ups were primarily emotional (eg, anxiety and distress), not physical, and ultimately positive for the majority. Health distress and fear of cancer and death were the major negative aspects of HRQoL identified. These concepts are not typically included in generic HRQoL questionnaires like the SF-36, but are highly relevant to PLCO screening. Clinicians were regarded as underestimating the discomfort of follow-up diagnostic testing. However, relief and assurance appeared to eventually outweigh the negative emotions for most participants. Implications for oncology nurses include the need to consider the emotional consequences of screening in association with screen reliability and validity.
Kim, Won Hwa; Kim, Hye Jung; Jung, Jin Hyang; Park, Ho Yong; Lee, Jeeyeon; Kim, Wan Wook; Park, Ji Young; Cheon, Hyejin; Lee, So Mi; Cho, Seung Hyun; Shin, Kyung Min; Kim, Gab Chul
2017-11-01
Ultrasonography-guided fine-needle aspiration (US-guided FNA) for axillary lymph nodes (ALNs) is currently used with various techniques for the initial staging of breast cancer and tagging of ALNs. With the implementation of the tattooing of biopsied ALNs, the rate of false-negative results of US-guided FNA for non-palpable and suspicious ALNs and concordance with sentinel lymph nodes were determined by node-to node analyses. A total of 61 patients with breast cancer had negative results for metastasis on US-guided FNA of their non-palpable and suspicious ALNs. The biopsied ALNs were tattooed with an injection of 1-3 mL Charcotrace (Phebra, Lane Cove West, Australia) ink and removed during sentinel lymph node biopsy or axillary dissection. We determined the rate of false-negative results and concordance with the sentinel lymph nodes by a retrospective review of surgical and pathologic findings. The association of false-negative results with clinical and imaging factors was evaluated using logistic regression. Of the 61 ALNs with negative results for US-guided FNA, 13 (21%) had metastases on final pathology. In 56 of 61 ALNs (92%), tattooed ALNs corresponded to the sentinel lymph nodes. Among the 5 patients (8%) without correspondence, 1 patient (2%) had 2 metastatic ALNs of 1 tattooed node and 1 sentinel lymph node. In multivariate analysis, atypical cells on FNA results (odds ratio = 20.7, p = 0.040) was independently associated with false-negative FNA results. False-negative ALNs after US-guided FNA occur at a rate of 21% and most of the tattooed ALNs showed concordance with sentinel lymph nodes. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
An empirical probability model of detecting species at low densities.
Delaney, David G; Leung, Brian
2010-06-01
False negatives, not detecting things that are actually present, are an important but understudied problem. False negatives are the result of our inability to perfectly detect species, especially those at low density such as endangered species or newly arriving introduced species. They reduce our ability to interpret presence-absence survey data and make sound management decisions (e.g., rapid response). To reduce the probability of false negatives, we need to compare the efficacy and sensitivity of different sampling approaches and quantify an unbiased estimate of the probability of detection. We conducted field experiments in the intertidal zone of New England and New York to test the sensitivity of two sampling approaches (quadrat vs. total area search, TAS), given different target characteristics (mobile vs. sessile). Using logistic regression we built detection curves for each sampling approach that related the sampling intensity and the density of targets to the probability of detection. The TAS approach reduced the probability of false negatives and detected targets faster than the quadrat approach. Mobility of targets increased the time to detection but did not affect detection success. Finally, we interpreted two years of presence-absence data on the distribution of the Asian shore crab (Hemigrapsus sanguineus) in New England and New York, using our probability model for false negatives. The type of experimental approach in this paper can help to reduce false negatives and increase our ability to detect species at low densities by refining sampling approaches, which can guide conservation strategies and management decisions in various areas of ecology such as conservation biology and invasion ecology.
Carrera, D; de la Flor, M; Galera, J; Amillano, K; Gomez, M; Izquierdo, V; Aguilar, E; López, S; Martínez, M; Martínez, S; Serra, J M; Pérez, M; Martin, L
2016-01-01
The aim of our study was to evaluate sentinel lymph node biopsy as a diagnostic test for assessing the presence of residual metastatic axillary lymph nodes after neoadjuvant chemotherapy, replacing the need for a lymphadenectomy in negative selective lymph node biopsy patients. A multicentre, diagnostic validation study was conducted in the province of Tarragona, on women with T1-T3, N1-N2 breast cancer, who presented with a complete axillary response after neoadjuvant chemotherapy. Study procedures consisted of performing an selective lymph node biopsy followed by lymphadenectomy. A total of 53 women were included in the study. Surgical detection rate was 90.5% (no sentinel node found in 5 patients). Histopathological analysis of the lymphadenectomy showed complete disease regression of axillary nodes in 35.4% (17/48) of the patients, and residual axillary node involvement in 64.6% (31/48) of them. In lymphadenectomy positive patients, 28 had a positive selective lymph node biopsy (true positive), while 3 had a negative selective lymph node biopsy (false negative). Of the 28 true selective lymph node biopsy positives, the sentinel node was the only positive node in 10 cases. All lymphadenectomy negative cases were selective lymph node biopsy negative. These data yield a sensitivity of 93.5%, a false negative rate of 9.7%, and a global test efficiency of 93.7%. Selective lymph node biopsy after chemotherapy in patients with a complete axillary response provides valid and reliable information regarding axillary status after neoadjuvant treatment, and might prevent lymphadenectomy in cases with negative selective lymph node biopsy. Copyright © 2016 Elsevier España, S.L.U. and SEMNIM. All rights reserved.
In-111 WBC imaging in musculoskeletal sepsis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, L.; Ouzounian, T.J.; Webber, M.M.
This study evaluated the accuracy and utility of the In-111 labeled WBC imaging in a series of patients who were suspected of having musculoskeletal sepsis. The labeling of the WBCs was patterned after a method previously described, in which the WBCs are labeled with In-111 oxine in plasma. The WBCs from 100 ml of blood are separated and incubated with In-111 oxine complex, and then 500 ..mu..Ci. of the labeled cells were reinjected into the patient. Images of the areas in question were obtained at 24 hrs. In some instances, 48 hour images were also obtained. Images were interpreted usingmore » consistent criteria. Forty imaging procedures were done on 39 patients. These included 39 total joint protheses, and 17 other images to evaluate possible osteomyelitis, septic arthritis or deep abscesses. Of these studies, 15 were positive, and 42 negative. The findings were then correlated with operative culture and pathology in 21, aspiration cultures and gram stains in 14, and with clinical findings in the remaining 21. This correlation showed 41 true negatives, 12 true positives, 1 false negative, and 2 false positives. The sensitivity was 92.9% and the specificity was 95.2%l. The false negative occurred in a patient on chronic suppressive antibiotic therapy for an infected total hip replacement. The false positive images occurred in a patient with active rheumatoid arthritis and in a patient imaged one month post operative placement of the prosthesis. These images were very useful in several septic patients who had many possible sites of infection. The authors conclude that In-III imaging is an accurate and useful non-invasive method of evaluating musculoskeletal sepsis.« less
Sullivan, John; Ring, Susan M.; Macleod, John; Hickman, Matthew
2016-01-01
Abstract Aims We investigate the extent of and factors associated with denial of previously reported cannabis and other illicit drug use, and assess the potential of hair testing for measuring substance use in general population samples. Design Birth cohort study. Setting United Kingdom, 1991–present. Participants A total of 3643 participants who provided hair and self‐report measures of cannabis and other illicit drug use in the Avon Longitudinal Study of Parents and Children (ALSPAC) at age 18 years. Measurements Denial of ever use of cannabis and other illicit drugs at age 18 following previously reported use. Positive hair drug tests for cannabis and other illicit drugs, and expected numbers of false positives and false negatives based on expected sensitivity and specificity. Findings Cannabis and other illicit drug use was reported by 1223 and 393 individuals, respectively, before age 18 years. Of these 176 (14.4%) and 99 (25.2%), respectively, denied use at age 18. Denial of cannabis use decreased with the reporting of other substances and antisocial behaviour. Cannabis and other illicit drug use at age 18 was reported by 547 (22.5%) and 203 (8.4%) individuals, respectively. Of these, 111 (20.3%) and 13 (6.4%) were hair‐positive for cannabis and other illicit drugs, respectively. Based on hair testing for cannabis use we expect 0 [95% confidence interval (CI) = 0–169] false positives and 394 (95% CI = 323–449) false negatives compared to observed 362 potential false positives and 436 potential false negatives based on self‐report. In hair‐positive individuals, reporting the use of other substances and antisocial behaviour decreased the odds of a negative self‐report. Conclusions Hair analysis provides an unreliable marker of substance use in general population samples. People who report more frequent substance use before age 18 are less likely to later deny previous substance use at age 18 than people who report occasional use. PMID:27743424
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haase, G.M.; Sfakianakis, G.N.; Lobe, T.E.
1981-06-01
The ability of external imaging to demonstrate intestinal infarction in neonatal necrotizing enterocolitis (NEC) was prospectively evaluated. The radiopharmaceutical technetium--99m diphosphonate was injected intravenously and the patients subsequently underwent abdominal scanning. Clinical patient care and interpretation of the images were entirely independent throughout the study. Of 33 studies, 7 were positive, 4 were suspicious, and 22 were negative. One false positive study detected ischemia without transmural infarction. The second false positive scan occurred postoperatively and was due to misinterpretation of the hyperactivity along the surgical incision. None of the suspicious cases had damaged bowel. The two false negative studies clearlymore » failed to demonstrate frank intestinal necrosis. The presence of very small areas of infarction, errors in technical settings, subjective interpretation of scans and delayed clearance of the radionuclide in a critically ill neonate may all limit the accuracy of external abdominal scanning. However, in spite of an error rate of 12%, it is likely that this technique will enhance the present clinical, laboratory, and radiologic parameters of patient management in NEC.« less
Pan, Liping; Jia, Hongyan; Liu, Fei; Sun, Huishan; Gao, Mengqiu; Du, Fengjiao; Xing, Aiying; Du, Boping; Sun, Qi; Wei, Rongrong; Gu, Shuxiang; Zhang, Zongde
2015-04-01
To investigate the risk factors for false-negative T-SPOT.TB results in patients with pulmonary TB (PTB) and extra-pulmonary TB (EPTB). Patients with suspected TB who underwent valid T-SPOT.TB tests were prospectively enrolled at Beijing Chest Hospital between November 2012 and November 2013. Basic characters and clinical laboratory findings were compared between true-positive and false-negative T-SPOT.TB groups. Of 1928 suspected TB patients, 774 (530 PTB and 244 EPTB) microbiologically/histopathogenically-confirmed patients (636 culture-confirmed) were analyzed. Forty-six PTB patients (8.7%) and 32 EPTB patients (13.1%) had negative T-SPOT.TB results. Multivariate analysis showed that increased age [odds radio (OR) 2.26, 95% confidence interval (CI) 1.11-4.58], over-weight (BMI ≥ 25 kg/m(2), OR 2.43, 95% CI 1.05-5.63), and a longer period of illness before hospitalization (>6 months, OR 2.46, 95% CI 1.24-4.92) were independent risk factors for false-negative T-SPOT.TB results in PTB patients. In EPTB patients, increased age (OR 2.42, 95% CI 1.09-5.35) also showed an independent association with false-negative T-SPOT.TB results. Careful interpretation of negative T-SPOT.TB results is necessary in older patients with suspected PTB or EPTB, and in PTB patients who are over-weight or have had longer periods of illness before hospitalization. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
Tirnaksiz, M B; Deschamps, C; Allen, M S; Johnson, D C; Pairolero, P C
2005-01-01
Aqueous contrast swallow study is recommended as a screening procedure for the evaluation of esophageal anastomotic integrity following esophagectomy. The aim of this study was to assess the accuracy of water-soluble contrast swallow screening as a predictor of clinically significant anastomotic leak in patients with esophagectomy. The records of 505 consecutive patients undergoing esophagectomy in Mayo Clinic from January 1991 through December 1995 were retrospectively reviewed. 464 (92%) patients had water-soluble contrast swallows performed in the early postoperative period (median postoperative day 7, range 4-11 days). A total of 39 radiological leaks were obtained but only 17 of these had clinical signs of anastomotic leakage. Furthermore, 25 patients who had normal swallow study developed a clinical anastomotic leak. There were therefore 22 (4.7%) false positive and 25 (5.4%) false negative results giving values for the specificity, sensitivity and false negative error rate of the radiological examination of 94.7, 40.4, and 59.5% respectively. Aspiration of the contrast agent was noted on fluoroscopy in 30 (6.5%) patients. Only 2 (0.4%) patients developed aqueous contrast agent-caused aspiration pneumonia. There was no procedure-related mortality. While radiological assessment of esophageal anastomoses in the early postoperative period using aqueous contrast agents appears to be a relatively safe procedure, the poor sensitivity and high false negative error rate of this technique, when performed on postoperative day 7 and in a series with clinical anastomotic leak rate of 9%, is insufficient for it to be worthwhile as a screening procedure. Copyright (c) 2005 S. Karger AG, Basel.
Ratnarajan, Gokulan; Kean, Jane; French, Karen; Parker, Mike; Bourne, Rupert
2015-09-01
To establish the safety of the CHANGES glaucoma referral refinement scheme (GRRS). The CHANGES scheme risk stratifies glaucoma referrals, with low risk referrals seen by a community based specialist optometrist (OSI) while high risk referrals are referred directly to the hospital. In this study, those patients discharged by the OSI were reviewed by the consultant ophthalmologist to establish a 'false negative' rate (Study 1). Virtual review of optic disc photographs was carried out both by a hospital-based specialist optometrist as well as the consultant ophthalmologist (Study 2). None of these 34 discharged patients seen by the consultant were found to have glaucoma or started on treatment to lower the intra-ocular pressure. Five of the 34 (15%) were classified as 'glaucoma suspect' based on the appearance of the optic disc and offered a follow-up appointment. Virtual review by both the consultant and optometrist had a sensitivity of 80%, whilst the false positive rate for the optometrist was 3.4%, and 32% for the consultant (p < 0.05). The false negative rate of the OSIs in the CHANGES scheme was 15%, however there were no patients where glaucoma was missed. Virtual review in experienced hands can be as effective as clinical review by a consultant, and is a valid method to ensure glaucoma is not missed in GRRS. The CHANGES scheme, which includes virtual review, is effective at reducing referrals to the hospital whilst not compromising patient safety. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.
True detection limits in an experimental linearly heteroscedastic system. Part 1
NASA Astrophysics Data System (ADS)
Voigtman, Edward; Abraham, Kevin T.
2011-11-01
Using a lab-constructed laser-excited filter fluorimeter deliberately designed to exhibit linearly heteroscedastic, additive Gaussian noise, it has been shown that accurate estimates may be made of the true theoretical Currie decision levels ( YC and XC) and true Currie detection limits ( YD and XD) for the detection of rhodamine 6 G tetrafluoroborate in ethanol. The obtained experimental values, for 5% probability of false positives and 5% probability of false negatives, were YC = 56.1 mV, YD = 125. mV, XC = 0.132 μg /mL and XD = 0.294 μg /mL. For 5% probability of false positives and 1% probability of false negatives, the obtained detection limits were YD = 158. mV and XD = 0.372 μg /mL. These decision levels and corresponding detection limits were shown to pass the ultimate test: they resulted in observed probabilities of false positives and false negatives that were statistically equivalent to the a priori specified values.
Kufa, Tendesayi; Kharsany, Ayesha BM; Cawood, Cherie; Khanyile, David; Lewis, Lara; Grobler, Anneke; Chipeta, Zawadi; Bere, Alfred; Glenshaw, Mary; Puren, Adrian
2017-01-01
Abstract Introduction: We describe the overall accuracy and performance of a serial rapid HIV testing algorithm used in community-based HIV testing in the context of a population-based household survey conducted in two sub-districts of uMgungundlovu district, KwaZulu-Natal, South Africa, against reference fourth-generation HIV-1/2 antibody and p24 antigen combination immunoassays. We discuss implications of the findings on rapid HIV testing programmes. Methods: Cross-sectional design: Following enrolment into the survey, questionnaires were administered to eligible and consenting participants in order to obtain demographic and HIV-related data. Peripheral blood samples were collected for HIV-related testing. Participants were offered community-based HIV testing in the home by trained field workers using a serial algorithm with two rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using two fourth-generation immunoassays with all positives in the confirmatory test considered true positives. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value and false-positive and false-negative rates were determined. Results: Of 10,236 individuals enrolled in the survey, 3740 were tested in the home (median age 24 years (interquartile range 19–31 years), 42.1% males and HIV positivity on RDT algorithm 8.0%). From those tested, 3729 (99.7%) had a definitive RDT result as well as a laboratory immunoassay result. The overall accuracy of the RDT when compared to the fourth-generation immunoassays was 98.8% (95% confidence interval (CI) 98.5–99.2). The sensitivity, specificity, positive predictive value and negative predictive value were 91.1% (95% CI 87.5–93.7), 99.9% (95% CI 99.8–100), 99.3% (95% CI 97.4–99.8) and 99.1% (95% CI 98.8–99.4) respectively. The false-positive and false-negative rates were 0.06% (95% CI 0.01–0.24) and 8.9% (95% CI 6.3–12.53). Compared to true positives, false negatives were more likely to be recently infected on limited antigen avidity assay and to report antiretroviral therapy (ART) use. Conclusions: The overall accuracy of the RDT algorithm was high. However, there were few false positives, and the sensitivity was lower than expected with high false negatives, despite implementation of quality assurance measures. False negatives were associated with recent (early) infection and ART exposure. The RDT algorithm was able to correctly identify the majority of HIV infections in community-based HIV testing. Messaging on the potential for false positives and false negatives should be included in these programmes. PMID:28872274
Are the memories of older adults positively biased?
Fernandes, Myra; Ross, Michael; Wiegand, Melanie; Schryer, Emily
2008-06-01
There is disagreement in the literature about whether a "positivity effect" in memory performance exists in older adults. To assess the generalizability of the effect, the authors examined memory for autobiographical, picture, and word information in a group of younger (17-29 years old) and older (60-84 years old) adults. For the autobiographical memory task, the authors asked participants to produce 4 positive, 4 negative, and 4 neutral recent autobiographical memories and to recall these a week later. For the picture and word tasks, participants studied photos or words of different valences (positive, negative, neutral) and later remembered them on a free-recall test. The authors found significant correlations in memory performance, across task material, for recall of both positive and neutral valence autobiographical events, pictures, and words. When the authors examined accurate memories, they failed to find consistent evidence, across the different types of material, of a positivity effect in either age group. However, the false memory findings offer more consistent support for a positivity effect in older adults. During recall of all 3 types of material, older participants recalled more false positive than false negative memories.
Alonso, Roberto; Pérez-García, Felipe; Gijón, Paloma; Collazos, Ana; Bouza, Emilio
2018-06-01
The Architect HIV Ag/Ab Combo Assay, a fourth-generation ELISA, has proven to be highly reliable for the diagnosis of HIV infection. However, its high sensitivity may lead to false-positive results. To evaluate the diagnostic performance of Architect in a low-prevalence population and to assess the role of the sample-to-cutoff ratio (S/CO) in reducing the frequency of false-positive results. We conducted a retrospective study of samples analyzed by Architect between January 2015 and June 2017. Positive samples were confirmed by immunoblot (RIBA) or nucleic acid amplification tests (NAATs). Different S/CO thresholds (1, 2.5, 10, 25, and 100) were analyzed to determine sensitivity, specificity, and negative and positive predictive values (NPV, PPV). ROC analysis was used to determine the optimal S/CO. A total of 69,471 samples were analyzed. 709 (1.02%) were positive by Architect. Of these, 63 (8.89%) were false-positive results. Most of them (93.65%) were in samples with S/CO < 100. However, most confirmations by NAATs (12 out of 19 cases) were also recorded for these samples. The optimal S/CO was 2.5, which provided the highest area under the ROC curve (0.9998) and no false-negative results. With this S/CO, sensitivity and specificity were 100.0%, and PPV and NPV were 95.8% and 100.0%, respectively. In addition, the frequency of false-positive results decreased significantly to 4.15%. Although Architect generates a relatively high number of false-positive results, raising the S/CO limit too much to increase specificity can lead to false-negative results, especially in newly infected individuals. Copyright © 2018 Elsevier B.V. All rights reserved.
El-Sayed, Abdulrahman M; Lauderdale, Diane S; Galea, Sandro
2010-12-01
Data about Arab-Americans, a growing ethnic minority, are not routinely collected in vital statistics, registry, or administrative data in the USA. The difficulty in identifying Arab-Americans using publicly available data sources is a barrier to health research about this group. Here, we validate an empirically based probabilistic Arab name algorithm (ANA) for identifying Arab-Americans in health research. We used data from all Michigan birth certificates between 2000 and 2005. Fathers' surnames and mothers' maiden names were coded as Arab or non-Arab according to the ANA. We calculated sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) of Arab ethnicity inferred using the ANA as compared to self-reported Arab ancestry. Statewide, the ANA had a specificity of 98.9%, a sensitivity of 50.3%, a PPV of 57.0%, and an NPV of 98.6%. Both the false-positive and false-negative rates were higher among men than among women. As the concentration of Arab-Americans in a study locality increased, the ANA false-positive rate increased and false-negative rate decreased. The ANA is highly specific but only moderately sensitive as a means of detecting Arab ancestry. Future research should compare health characteristics among Arab-American populations defined by Arab ancestry and those defined by the ANA.
Ko, Kyung Dae; El-Ghazawi, Tarek; Kim, Dongkyu; Morizono, Hiroki
2014-05-01
Motor neuron diseases (MNDs) are a class of progressive neurological diseases that damage the motor neurons. An accurate diagnosis is important for the treatment of patients with MNDs because there is no standard cure for the MNDs. However, the rates of false positive and false negative diagnoses are still very high in this class of diseases. In the case of Amyotrophic Lateral Sclerosis (ALS), current estimates indicate 10% of diagnoses are false-positives, while 44% appear to be false negatives. In this study, we developed a new methodology to profile specific medical information from patient medical records for predicting the progression of motor neuron diseases. We implemented a system using Hbase and the Random forest classifier of Apache Mahout to profile medical records provided by the Pooled Resource Open-Access ALS Clinical Trials Database (PRO-ACT) site, and we achieved 66% accuracy in the prediction of ALS progress.
Network Compression as a Quality Measure for Protein Interaction Networks
Royer, Loic; Reimann, Matthias; Stewart, A. Francis; Schroeder, Michael
2012-01-01
With the advent of large-scale protein interaction studies, there is much debate about data quality. Can different noise levels in the measurements be assessed by analyzing network structure? Because proteomic regulation is inherently co-operative, modular and redundant, it is inherently compressible when represented as a network. Here we propose that network compression can be used to compare false positive and false negative noise levels in protein interaction networks. We validate this hypothesis by first confirming the detrimental effect of false positives and false negatives. Second, we show that gold standard networks are more compressible. Third, we show that compressibility correlates with co-expression, co-localization, and shared function. Fourth, we also observe correlation with better protein tagging methods, physiological expression in contrast to over-expression of tagged proteins, and smart pooling approaches for yeast two-hybrid screens. Overall, this new measure is a proxy for both sensitivity and specificity and gives complementary information to standard measures such as average degree and clustering coefficients. PMID:22719828
Engberts, Marian K; Goedbloed, Annelize F; van Haaften, Maarten; van Haaften, Mathilde; Boon, Mathilde E; Boon, Maarten E; Heintz, Peter M
2007-01-01
To determine the accuracy of the microscopic diagnosis of vulvovaginal candidiasis (presence of [pseudo] hyphae and blastospores) in stained vaginal smears in clinical practice. General practitioners trained in diagnosing vulvovaginal candidiasis performed microscopy of 324 stained vaginal smears. These smears were sent to the pathologist for confirmation of the microscopic diagnosis of the clinician; cytologic diagnosis by the pathologist was considered the gold standard. In 104 of the 342 cases Candida was established by the pathologist. The clinicians made 24 false positive and 50 false negative diagnoses of Candida. Sensitivity and specificity of the microscopic diagnoses of the clinicians were 52% and 89%, respectively. The most frequent reason for a false positive diagnosis was presence of hairs, whereas the most frequent reason for a false negative diagnosis was understaining of the smear. This study shows that even in stained smears it is difficult for clinicians to recognize blastospores and (pseudo)hyphae. Efforts are clearly needed to improve the quality of the clinical diagnosis of vulvovaginal candidiasis.
Lee, Jae Seok; Kim, Eui-Chong; Joo, Sei Ick; Lee, Sang-Min; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Shim, Young-Soo; Yim, Jae-Joon
2008-10-01
Although it is not rare to find sputum that is positive acid-fast bacilli (AFB) smear but subsequent culture fails to isolate mycobacteria in clinical practice, the incidence and clinical implication of those sputa from new patients has not been clearly elucidated. The aim of this study was to determine the incidence and clinical implication of sputum with positive AFB smear but negative in mycobacterial culture. All sputa that were positive AFB smear requested during diagnostic work up for new patients visiting Seoul National University Hospital from 1 January 2005 through 31 December 2006 were included. Sputa producing a positive AFB smear but negative mycobacterial culture were classified into one of four categories: laboratory failure to isolate mycobacteria, false positive AFB smear, pathogen may show a positive AFB smear other than mycobacteria, and indeterminate results. Out of 447 sputa with a positive AFB smear, 29 (6.5%) failed to culture any organism. Among these 29 sputa, 18 were caused by laboratory failure to isolate mycobacteria, six were false positive smears, and five indeterminate. Although most sputum with a positive AFB smear but negative culture could be classified as a laboratory failure, clinicians should consider the possibility of false positive AFB smear.
Ackermann, S.; Schoenenberger, C.-A.; Zanetti-Dällenbach, R.
2016-01-01
Purpose: Ultrasound (US) is a well-established diagnostic procedure for breast examination. We investigated the malignancy rate in solid breast lesions according to their BI-RADS classification with a particular focus on false-negative BI-RADS 3 lesions. We examined whether patient history and clinical findings could provide additional information that would help determine further diagnostic steps in breast lesions. Materials and Methods: We conducted a retrospective study by exploring US BI-RADS in 1469 breast lesions of 1201 patients who underwent minimally invasive breast biopsy (MIBB) from January 2002 to December 2011. Results: The overall sensitivity and specificity of BI-RADS classification was 97.4% and 66.4%, respectively, with a positive (PPV) and negative predictive value (NPV) of 65% and 98%, respectively. In 506 BI-RADS 3 lesions, histology revealed 15 malignancies (2.4% malignancy rate), which corresponds to a false-negative rate (FNR) of 2.6%. Clinical evaluation and patient requests critically influenced the further diagnostic procedure, thereby prevailing over the recommendation given by the BI-RADS 3 classification. Conclusion: Clinical criteria including age, family and personal history, clinical examination, mammography and patient choice ensure adequate diagnostic procedures such as short-term follow-up or MIBB in patients with lesions classified as US-BI-RADS 3. PMID:27689181
What Is a False Negative Sentinel Node Biopsy: Definition, Reasons and Ways to Minimize It?
Kataria, Kamal; Srivastava, Anurag; Qaiser, Darakhshan
2016-10-01
Sentinel node biopsy helps in assessing the involvement of axillary lymph node without the morbidity of full axillary lymph node dissection, namely arm and shoulder pain, paraesthesia and lymphoedema. The various methods described in the literature identify the sentinel lymph nodes in approximately 96 % of cases and associated with a false negativity rate of 5 to 10 %. A false negative sentinel node is defined as the proportion of cases in whom sentinel node biopsy is reported as negative, but the rest of axillary lymph node(s) harbours cancer cells. The possible causes of a false negative sentinel lymph node may be because of blocked lymphatics either by cancer cells or following fibrosis of previous surgery/radiotherapy, and an alternative pathway opens draining the blue dye or isotope to another uninvolved node . The other reasons may be two lymphatic pathways for a tumour area, the one opening to a superficial node and the other in deep nodes. Sometimes, lymphatics do not relay into a node but traverse it going to a higher node. In some patients, the microscopic focus of metastasis inside a lymph node is so small-micrometastasis (i.e. between 0.2 and 2 mm) or isolated tumour cells (i.e. less than 0.2 mm) that is missed by the pathologist. The purpose of this review is to clear some fears lurking in the mind of most surgeons about the false negative sentinel lymph node (FNSLN).
A Study of False-Positive and False-Negative Error Rates in Cartridge Case Comparisons
2014-04-07
materials for the study, in particular Vicki Sieve. 3 Abstract: This report provides the details for a study designed to...participate in ASCLD were provided with 15 sets of 3 known + 1 unknown cartridge cases fired from a collection of 25 new Ruger SR9 handguns . The...answer sheet allowing for the AFTE range of conclusions, and return shipping materials . They were also asked to assess how many of the 3 knowns were
Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Hwang, Jae Jin; Lee, Hyun Joo; Lee, AeRa; Jeong, Yeon Sang; Oh, Sooyeon; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho
2015-06-01
The (13)C-urea breath test ((13)C-UBT) is a noninvasive method for diagnosing Helicobacter pylori (H. pylori) infection. The aims of this study were to evaluate the diagnostic validity of the (13)C-UBT cutoff value and to identify influencing clinical factors responsible for aberrant results. (13)C-UBT (UBiTkit; Otsuka Pharmaceutical, cutoff value: 2.5‰) results in the range 2.0‰ to 10.0‰ after H. pylori eradication therapy were compared with the results of endoscopic biopsy results of the antrum and body. Factors considered to affect test results adversely were analyzed. Among patients with a positive (13)C-UBT result (2.5‰ to 10.0‰, n = 223) or a negative (13)C-UBT result (2.0‰ to < 2.5‰, n = 66) after H. pylori eradication, 73 patients (34.0%) were false positive, and one (1.5%) was false negative as determined by endoscopic biopsy. The sensitivity, specificity, false-positive rate, and false-negative rate for a cutoff value of 2.5‰ were 99.3%, 47.1%, 52.9%, and 0.7%, respectively, and positive and negative predictive values of the (13)C-UBT were 67.3% and 98.5%, respectively. Multivariate analysis showed that a history of two or more previous H. pylori eradication therapies (OR = 2.455, 95%CI = 1.299-4.641) and moderate to severe gastric intestinal metaplasia (OR = 3.359, 95%CI = 1.572-7.178) were associated with a false-positive (13)C-UBT result. The (13)C-UBT cutoff value currently used has poor specificity for confirming H. pylori status after eradication, and this lack of specificity is exacerbated in patients that have undergone multiple prior eradication therapies and in patients with moderate to severe gastric intestinal metaplasia. In addition, the citric-free (13)C-UBT would increase a false-positive (13)C-UBT result. © 2015 John Wiley & Sons Ltd.
Qualitative PCR method for Roundup Ready soybean: interlaboratory study.
Kodama, Takashi; Kasahara, Masaki; Minegishi, Yasutaka; Futo, Satoshi; Sawada, Chihiro; Watai, Masatoshi; Akiyama, Hiroshi; Teshima, Reiko; Kurosawa, Yasunori; Furui, Satoshi; Hino, Akihiro; Kitta, Kazumi
2011-01-01
Quantitative and qualitative methods based on PCR have been developed for genetically modified organisms (GMO). Interlaboratory studies were previously conducted for GMO quantitative methods; in this study, an interlaboratory study was conducted for a qualitative method for a GM soybean, Roundup Ready soy (RR soy), with primer pairs designed for the quantitative method of RR soy studied previously. Fourteen laboratories in Japan participated. Each participant extracted DNA from 1.0 g each of the soy samples containing 0, 0.05, and 0.10% of RR soy, and performed PCR with primer pairs for an internal control gene (Le1) and RR soy followed by agarose gel electrophoresis. The PCR product amplified in this PCR system for Le1 was detected from all samples. The sensitivity, specificity, and false-negative and false-positive rates of the method were obtained from the results of RR soy detection. False-negative rates at the level of 0.05 and 0.10% of the RR soy samples were 6.0 and 2.3%, respectively, revealing that the LOD of the method was somewhat below 0.10%. The current study demonstrated that the qualitative method would be practical for monitoring the labeling system of GM soy in kernel lots.
ClubSub-P: Cluster-Based Subcellular Localization Prediction for Gram-Negative Bacteria and Archaea
Paramasivam, Nagarajan; Linke, Dirk
2011-01-01
The subcellular localization (SCL) of proteins provides important clues to their function in a cell. In our efforts to predict useful vaccine targets against Gram-negative bacteria, we noticed that misannotated start codons frequently lead to wrongly assigned SCLs. This and other problems in SCL prediction, such as the relatively high false-positive and false-negative rates of some tools, can be avoided by applying multiple prediction tools to groups of homologous proteins. Here we present ClubSub-P, an online database that combines existing SCL prediction tools into a consensus pipeline from more than 600 proteomes of fully sequenced microorganisms. On top of the consensus prediction at the level of single sequences, the tool uses clusters of homologous proteins from Gram-negative bacteria and from Archaea to eliminate false-positive and false-negative predictions. ClubSub-P can assign the SCL of proteins from Gram-negative bacteria and Archaea with high precision. The database is searchable, and can easily be expanded using either new bacterial genomes or new prediction tools as they become available. This will further improve the performance of the SCL prediction, as well as the detection of misannotated start codons and other annotation errors. ClubSub-P is available online at http://toolkit.tuebingen.mpg.de/clubsubp/ PMID:22073040
Applying a CAD-generated imaging marker to assess short-term breast cancer risk
NASA Astrophysics Data System (ADS)
Mirniaharikandehei, Seyedehnafiseh; Zarafshani, Ali; Heidari, Morteza; Wang, Yunzhi; Aghaei, Faranak; Zheng, Bin
2018-02-01
Although whether using computer-aided detection (CAD) helps improve radiologists' performance in reading and interpreting mammograms is controversy due to higher false-positive detection rates, objective of this study is to investigate and test a new hypothesis that CAD-generated false-positives, in particular, the bilateral summation of false-positives, is a potential imaging marker associated with short-term breast cancer risk. An image dataset involving negative screening mammograms acquired from 1,044 women was retrospectively assembled. Each case involves 4 images of craniocaudal (CC) and mediolateral oblique (MLO) view of the left and right breasts. In the next subsequent mammography screening, 402 cases were positive for cancer detected and 642 remained negative. A CAD scheme was applied to process all "prior" negative mammograms. Some features from CAD scheme were extracted, which include detection seeds, the total number of false-positive regions, an average of detection scores and the sum of detection scores in CC and MLO view images. Then the features computed from two bilateral images of left and right breasts from either CC or MLO view were combined. In order to predict the likelihood of each testing case being positive in the next subsequent screening, two logistic regression models were trained and tested using a leave-one-case-out based cross-validation method. Data analysis demonstrated the maximum prediction accuracy with an area under a ROC curve of AUC=0.65+/-0.017 and the maximum adjusted odds ratio of 4.49 with a 95% confidence interval of [2.95, 6.83]. The results also illustrated an increasing trend in the adjusted odds ratio and risk prediction scores (p<0.01). Thus, the study showed that CAD-generated false-positives might provide a new quantitative imaging marker to help assess short-term breast cancer risk.
Handheld echocardiographic screening for rheumatic heart disease by non-experts.
Ploutz, Michelle; Lu, Jimmy C; Scheel, Janet; Webb, Catherine; Ensing, Greg J; Aliku, Twalib; Lwabi, Peter; Sable, Craig; Beaton, Andrea
2016-01-01
Handheld echocardiography (HAND) has good sensitivity and specificity for rheumatic heart disease (RHD) when performed by cardiologists. However, physician shortages in RHD-endemic areas demand less-skilled users to make RHD screening practical. We examine nurse performance and interpretation of HAND using a simplified approach for RHD screening. Two nurses received training on HAND and a simplified screening approach. Consented students at two schools in Uganda were eligible for participation. A simplified approach (HAND performed and interpreted by a non-expert) was compared with the reference standard (standard portable echocardiography, performed and interpreted by experts according to the 2012 World Heart Federation guidelines). Reasons for false-positive and false-negative HAND studies were identified. A total of 1002 children were consented, with 956 (11.1 years, 41.8% male) having complete data for review. Diagnoses included: 913 (95.5%) children were classified normal, 32 (3.3%) borderline RHD and 11 (1.2%) definite RHD. The simplified approach had a sensitivity of 74.4% (58.8% to 86.5%) and a specificity of 78.8% (76.0% to 81.4%) for any RHD (borderline and definite). Sensitivity improved to 90.9% (58.7% to 98.5%) for definite RHD. Identification and measurement of erroneous colour jets was the most common reason for false-positive studies (n=164/194), while missed mitral regurgitation and shorter regurgitant jet lengths with HAND were the most common reasons for false-negative studies (n=10/11). Non-expert-led HAND screening programmes offer a potential solution to financial and workforce barriers that limit widespread RHD screening. Nurses trained on HAND using a simplified approach had reasonable sensitivity and specificity for RHD screening. Information on reasons for false-negative and false-positive screening studies should be used to inform future training protocols, which could lead to improved screening performance. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Cliquet, F; McElhinney, L M; Servat, A; Boucher, J M; Lowings, J P; Goddard, T; Mansfield, K L; Fooks, A R
2004-04-01
A protocol suitable for the detection of rabies virus-specific antibodies in serum samples from companion animals using an enzyme linked immunosorbent assay (ELISA) is described. This method has been used successfully for the qualitative assessment of rabies virus-specific antibodies in serum samples from a cohort of vaccinated dogs and cats. In two initial field studies, a variable population of field samples from the Veterinary Laboratories Agency (VLA), United Kingdom were tested. In the first study (n = 1000), the number of false-positive and false-negative results was 11 samples (1.1%) and 67 samples (6.7%), respectively. In the second study (n = 920), the number of false-positive and false-negative results was 7 samples (0.8%) and 52 samples (5.7%). In a third study, undertaken at l'Agence Française de Sécurité Sanitaire des Aliments (AFSSA), Nancy, France (n = 440), 1 false-positive sample (0.23%) and 91 (20.7%) false-negative samples were identified. Data generated using this prototype ELISA indicate a strong correlation for specificity when compared to the gold standard fluorescent antibody virus neutralisation (FAVN) test. Although the ELISA has a lower sensitivity than the FAVN test, it is a useful tool for rapidly screening serum samples from vaccinated companion animals. Using a cut-off value of 0.6 EU/ml, the sensitivity (R = % from VLA and 79% from AFSSA) and specificity (R = 97.3%) indices between the ELISA compared favourably with data generated using the FAVN test. The major advantages of the ELISA test are that it is a qualitative tool that can be completed in four hours, does not require the use of live virus and can be performed without the need for specialised laboratory containment. This contrasts with 4 days using conventional rabies antibody virus neutralisation assays. Using the current format, the ELISA assay described would be a valuable screening tool for the detection of rabies antibodies from vaccinated domestic animals in combination with other Office International des Epizooties (OIE) accepted serological tests.
Frequency of false-negative reactions to the fragrance mix.
de Groot, A C; van der Kley, A M; Bruynzeel, D P; Meinardi, M M; Smeenk, G; van Joost, T; Pavel, S
1993-03-01
To estimate the frequency of false-negative reactions to the fragrance mix, the 8 constituents of the mix in concentrations of 5% (2% for cinnamic aldehyde) were added to the European standard series for routine testing. Patients with positive reactions to individual ingredients in the absence of a reaction to the mix were retested with serial dilutions. In a 4-month period, 677 patients were tested. 61 (9%) reacted to the mix and to 1 or more of the ingredients. 4 patients (0.6% of all patients tested and 6.2% of the patients allergic to fragrances) had false-negative reactions to the mix. They were allergic to cinnamic alcohol, geraniol, isoeugenol and oak moss (1 reaction each), in the absence of a reaction to the fragrance mix. It is concluded that the currently used concentration of the mix (8 x 1%) not infrequently results in false-negative reactions, and that further research should be done to overcome this problem.
Emotionally Negative Pictures Enhance Gist Memory
Bookbinder, S. H.; Brainerd, C. J.
2016-01-01
In prior work on how true and false memory are influenced by emotion, valence and arousal have often been conflated. Thus, it is difficult to say which specific effects are due to valence and which are due to arousal. In the present research, we used a picture-memory paradigm that allowed emotional valence to be manipulated with arousal held constant. Negatively-valenced pictures elevated both true and false memory, relative to positive and neutral pictures. Conjoint recognition modeling revealed that negative valence (a) reduced erroneous suppression of true memories and (b) increased the familiarity of the semantic content of both true and false memories. Overall, negative valence impaired the verbatim side of episodic memory but enhanced the gist side, and these effects persisted even after a week-long delay. PMID:27454002
Le, Yali; Chen, Yu; Zhou, Fan; Liu, Guangfu; Huang, Zhanwen; Chen, Yue
2016-10-01
This study compared the diagnostic value of F-fluoride PET-computed tomography (PET-CT) and MRI in skull-base bone erosion in nasopharyngeal carcinoma (NPC) patients. A total of 93 patients with biopsy-confirmed NPC were enrolled, including 68 men and 25 women between 23 and 74 years of age. All patients were evaluated by both F-fluoride PET-CT and MRI, and the interval between the two imaging examinations was less than 20 days. The patients received no treatment either before or between scans. The studies were interpreted by two nuclear medicine physicians or two radiologists with more than 10 years of professional experience who were blinded to both the diagnosis and the results of the other imaging studies. The reference standard was skull-base bone erosion at a 20-week follow-up imaging study. On the basis of the results of the follow-up imaging studies, 52 patients showed skull-base bone erosion. The numbers of true positives, false positives, true negatives, and false negatives with F-fluoride PET-CT were 49, 4, 37, and 3, respectively. The numbers of true positives, false positives, true negatives, and false negatives with MRI were 46, 5, 36, and 6, respectively. The sensitivity, specificity, and crude accuracy of F-fluoride PET-CT were 94.23, 90.24, and 92.47%, respectively; for MRI, these values were 88.46, 87.80, and 88.17%. Of the 52 patients, 43 showed positive findings both on F-fluoride PET-CT and on MRI. Within the patient cohort, F-fluoride PET-CT and MRI detected 178 and 135 bone lesions, respectively. Both F-fluoride PET-CT and MRI have high sensitivity, specificity, and crude accuracy for detecting skull-base bone invasion in patients with NPC. F-fluoride PET-CT detected more lesions than did MRI in the skull-base bone. This suggests that F-fluoride PET-CT has a certain advantage in evaluating the skull-base bone of NPC patients. Combining the two methods could improve the diagnostic accuracy of skull-base bone invasion for NPC.
Karaceper, Maria D; Chakraborty, Pranesh; Coyle, Doug; Wilson, Kumanan; Kronick, Jonathan B; Hawken, Steven; Davies, Christine; Brownell, Marni; Dodds, Linda; Feigenbaum, Annette; Fell, Deshayne B; Grosse, Scott D; Guttmann, Astrid; Laberge, Anne-Marie; Mhanni, Aizeddin; Miller, Fiona A; Mitchell, John J; Nakhla, Meranda; Prasad, Chitra; Rockman-Greenberg, Cheryl; Sparkes, Rebecca; Wilson, Brenda J; Potter, Beth K
2016-02-03
There is no consensus in the literature regarding the impact of false positive newborn screening results on early health care utilization patterns. We evaluated the impact of false positive newborn screening results for medium-chain acyl-CoA dehydrogenase deficiency (MCADD) in a cohort of Ontario infants. The cohort included all children who received newborn screening in Ontario between April 1, 2006 and March 31, 2010. Newborn screening and diagnostic confirmation results were linked to province-wide health care administrative datasets covering physician visits, emergency department visits, and inpatient hospitalizations, to determine health service utilization from April 1, 2006 through March 31, 2012. Incidence rate ratios (IRRs) were used to compare those with false positive results for MCADD to those with negative newborn screening results, stratified by age at service use. We identified 43 infants with a false positive newborn screening result for MCADD during the study period. These infants experienced significantly higher rates of physician visits (IRR: 1.42) and hospitalizations (IRR: 2.32) in the first year of life relative to a screen negative cohort in adjusted analyses. Differences in health services use were not observed after the first year of life. The higher use of some health services among false positive infants during the first year of life may be explained by a psychosocial impact of false positive results on parental perceptions of infant health, and/or by differences in underlying health status. Understanding the impact of false positive newborn screening results can help to inform newborn screening programs in designing support and education for families. This is particularly important as additional disorders are added to expanded screening panels, yielding important clinical benefits for affected children but also a higher frequency of false positive findings.
ERIC Educational Resources Information Center
Bender, Stacy L.; Privitera, Gregory J.
2016-01-01
This study examined executive function (EF) skills and self-reported symptoms of ADHD. EF skills were measured to determine whether skills were different between groups that reported clinical levels of ADHD symptoms (clinical group) and nonclinical levels of ADHD symptoms (nonclinical group). EF skills in the nonclinical group were also…
Proactive and Retroactive Effects of Negative Suggestion
ERIC Educational Resources Information Center
Brown, Alan S.; Brown, Christine M.; Mosbacher, Joy L.; Dryden, W. Erich
2006-01-01
The negative effects of false information presented either prior to (proactive interference; PI) or following (retroactive interference; RI) true information was examined with word definitions (Experiment 1) and trivia facts (Experiment 2). Participants were explicitly aware of which information was true and false when shown, and true-false…
Rutegård, Martin; Kverneng Hultberg, Daniel; Angenete, Eva; Lydrup, Marie-Louise
2017-12-01
The causes and effects of anastomotic leakage after anterior resection are difficult to study in small samples and have thus been evaluated using large population-based national registries. To assess the accuracy of such research, registries should be validated continuously. Patients who underwent anterior resection for rectal cancer during 2007-2013 in 15 different hospitals in three healthcare regions in Sweden were included in the study. Registry data and information from patient records were retrieved. Registered anastomotic leakage within 30 postoperative days was evaluated, using all available registry data and using only the main variable anastomotic insufficiency. With the consensus definition of anastomotic leakage developed by the International Study Group on Rectal Cancer as reference, validity measures were calculated. Some 1507 patients were included in the study. The negative and positive predictive values for registered anastomotic leakage were 96 and 88%, respectively, while the κ-value amounted to 0.76. The false-negative rate was 29%, whereas the false-positive rate reached 1.3% (the vast majority consisting of actual leaks, but occurring after postoperative day 30). Using the main variable anastomotic insufficiency only, the false-negative rate rose to 41%. There is considerable underreporting of anastomotic leakage after anterior resection for rectal cancer in the Swedish Colorectal Cancer Registry. It is probable that this causes an underestimation of the true effects of leakage on patient outcomes, and further quality control is needed.
Comparison of one-tier and two-tier newborn screening metrics for congenital adrenal hyperplasia.
Sarafoglou, Kyriakie; Banks, Kathryn; Gaviglio, Amy; Hietala, Amy; McCann, Mark; Thomas, William
2012-11-01
Newborn screening (NBS) for the classic forms of congenital adrenal hyperplasia (CAH) is mandated in all states in the United States. Compared with other NBS disorders, the false-positive rate (FPR) of CAH screening remains high and has not been significantly improved by adjusting 17α-hydroxyprogesterone cutoff values for birth weight and/or gestational age. Minnesota was the first state to initiate, and only 1 of 4 states currently performing, second-tier steroid profiling for CAH. False-negative rates (FNRs) for CAH are not well known. This is a population-based study of all Minnesota infants (769,834) born 1999-2009, grouped by screening protocol (one-tier with repeat screen, January 1999 to May 2004; two-tier with second-tier steroid profiling, June 2004 to December 2009). FPR, FNR, and positive predictive value (PPV) were calculated per infant, rather than per sample, and compared between protocols. Overall, 15 false-negatives (4 salt-wasting, 11 simple-virilizing) and 45 true-positives were identified from 1999 to 2009. With two-tier screening, FNR was 32%, FPR increased to 0.065%, and PPV decreased to 8%, but these changes were not statistically significant. Second-tier steroid profiling obviated repeat screens of borderline results (355 per year average). In comparing the 2 screening protocols, the FPR of CAH NBS remains high, the PPV remains low, and false-negatives occur more frequently than has been reported. Physicians should be cautioned that a negative NBS does not necessarily rule out classic CAH; therefore, any patient for whom there is clinical concern for CAH should receive immediate diagnostic testing.
Deducing the Milky Way's Massive Cluster Population
NASA Astrophysics Data System (ADS)
Hanson, M. M.; Popescu, B.; Larsen, S. S.; Ivanov, V. D.
2010-11-01
Recent near-infrared surveys of the galactic plane have been used to identify new massive cluster candidates. Follow up study indicates about half are not true, gravitationally-bound clusters. These false positives are created by high density fields of unassociated stars, often due to a sight-line of reduced extinction. What is not so easy to estimate is the number of false negatives, clusters which exist but are not currently being detected by our surveys. In order to derive critical characteristics of the Milky Way's massive cluster population, such as cluster mass function and cluster lifetimes, one must be able to estimate the characteristics of these false negatives. Our group has taken on the daunting task of attempting such an estimate by first creating the stellar cluster imaging simulation program, MASSCLEAN. I will present our preliminary models and methods for deriving the biases of current searches.
Standoff detection of chemical and biological threats using laser-induced breakdown spectroscopy.
Gottfried, Jennifer L; De Lucia, Frank C; Munson, Chase A; Miziolek, Andrzej W
2008-04-01
Laser-induced breakdown spectroscopy (LIBS) is a promising technique for real-time chemical and biological warfare agent detection in the field. We have demonstrated the detection and discrimination of the biological warfare agent surrogates Bacillus subtilis (BG) (2% false negatives, 0% false positives) and ovalbumin (0% false negatives, 1% false positives) at 20 meters using standoff laser-induced breakdown spectroscopy (ST-LIBS) and linear correlation. Unknown interferent samples (not included in the model), samples on different substrates, and mixtures of BG and Arizona road dust have been classified with reasonable success using partial least squares discriminant analysis (PLS-DA). A few of the samples tested such as the soot (not included in the model) and the 25% BG:75% dust mixture resulted in a significant number of false positives or false negatives, respectively. Our preliminary results indicate that while LIBS is able to discriminate biomaterials with similar elemental compositions at standoff distances based on differences in key intensity ratios, further work is needed to reduce the number of false positives/negatives by refining the PLS-DA model to include a sufficient range of material classes and carefully selecting a detection threshold. In addition, we have demonstrated that LIBS can distinguish five different organophosphate nerve agent simulants at 20 meters, despite their similar stoichiometric formulas. Finally, a combined PLS-DA model for chemical, biological, and explosives detection using a single ST-LIBS sensor has been developed in order to demonstrate the potential of standoff LIBS for universal hazardous materials detection.
Role of re-screening of cervical smears in internal quality control.
Baker, A; Melcher, D; Smith, R
1995-01-01
AIMS--To investigate the use of rapid re-screening as a quality control method for previously screened cervical slides; to compare this method with 10% random re-screening and clinically indicated double screening. METHODS--Between June 1990 and December 1994, 117,890 negative smears were subjected to rapid re-screening. RESULTS--This study shows that rapid re-screening detects far greater numbers of false negative cases when compared with both 10% random re-screening and clinically indicated double screening, with no additional demand on human resources. The technique also identifies variation in the performance of screening personnel as an additional benefit. CONCLUSION--Rapid re-screening is an effective method of quality control. Although less sensitive, rapid re-screening should replace 10% random re-screening and selected re-screening as greater numbers of false negative results are detected while consuming less resources. PMID:8543619
Clinical experience with (/sup 111/ In) indium chloride scanning in inflammatory diseases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dayem, H.M.; Breen, J.; Leslie, E.V.
1978-05-01
Forty-eight patients were scanned with /sup 111/In-chloride in an attempt to identify the cause of fever. Fifteen true positive scans, 30 true negatives, and 3 false negatives were found. Of the 15 true positives, 7 cases of abdominal or pelvic abscess, and 8 cases of alcoholic hepatitis were detected. The 3 false negatives included: (1) an abscess in the anterior abdominal wall; (2) an abscess in the right upper quadrant at the site of a necrotic gallbladder; and (3) a tuberculous abscess of the lumbar spine. Examples from the different categories, pitfalls in interpretation and advantages and disadvantages of scanningmore » with /sup 111/In-chloride will be presented. These studies indicate that /sup 111/In-chloride is a safe, reliable scanning agent for abscesses below the diaphragm especially in patients who cannot undergo adequate bowel preparation.« less
Issa, Amalia M; Tufail, Waqas; Atehortua, Nelson; McKeever, John
2013-05-01
Molecular diagnostics are increasingly being used to help guide decision-making for personalized medical treatment of breast and colorectal cancer patients. The main aim of this study was to better understand and determine breast and colorectal cancer patients' decision-making strategies and the trade-offs they make in deciding about characteristics of molecular genomic diagnostics for breast and colorectal cancer. We surveyed a nationally representative sample of 300 breast and colorectal cancer patients using a previously developed web-administered instrument. Eligibility criteria included patients aged 18 years and older with either breast or colorectal cancer. We explored several attributes and attribute levels of molecular genomic diagnostics in 20 scenarios. Our analysis revealed that both breast and colorectal cancer patients weighted the capability of molecular genomic diagnostics to determine the probability of treatment efficacy as being of greater importance than information provided to detect adverse events. The probability of either false-positive or -negative results was ranked highly as a potential barrier by both breast and colorectal patients. However, 78.6% of breast cancer patients ranked the possibility of a 'false-negative test result leading to undertreatment' higher than the 'chance of a false positive, which may lead to overtreatment' (68%). This finding contrasted with the views of colorectal cancer patients who ranked the chance of a false positive as being of greater concern than a false negative (72.8 vs 63%). Overall, cancer patients exhibited a high willingness to accept and pay for genomic diagnostic tests, especially among breast cancer patients. Cancer patients seek a test accuracy rate of 90% or higher. Breast and colorectal cancer patients' decisions about genomic diagnostics are influenced more by the probability of being cured than by avoiding potential severe adverse events. This study provides insights into the relative weight that breast and colorectal cancer patients place on various aspects of molecular genomic diagnostics, and the trade-offs they are willing to make among attributes of such tests.
Emotionally negative pictures enhance gist memory.
Bookbinder, S H; Brainerd, C J
2017-02-01
In prior work on how true and false memory are influenced by emotion, valence and arousal have often been conflated. Thus, it is difficult to say which specific effects are caused by valence and which are caused by arousal. In the present research, we used a picture-memory paradigm that allowed emotional valence to be manipulated with arousal held constant. Negatively valenced pictures elevated both true and false memory, relative to positive and neutral pictures. Conjoint recognition modeling revealed that negative valence (a) reduced erroneous suppression of true memories and (b) increased the familiarity of the semantic content of both true and false memories. Overall, negative valence impaired the verbatim side of episodic memory but enhanced the gist side, and these effects persisted even after a week-long delay. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Jeremiah, S S; Balaji, V; Anandan, S; Sahni, R D
2014-01-01
The modified Hodge test (MHT) is widely used as a screening test for the detection of carbapenemases in Gram-negative bacteria. This test has several pitfalls in terms of validity and interpretation. Also the test has a very low sensitivity in detecting the New Delhi metallo-β-lactamase (NDM). Considering the degree of dissemination of the NDM and the growing pandemic of carbapenem resistance, a more accurate alternative test is needed at the earliest. The study intends to compare the performance of the MHT with the commercially available Neo-Sensitabs - Carbapenemases/Metallo-β-Lactamase (MBL) Confirmative Identification pack to find out whether the latter could be an efficient alternative to the former. A total of 105 isolates of Klebsiella pneumoniae resistant to imipenem and meropenem, collected prospectively over a period of 2 years were included in the study. The study isolates were tested with the MHT, the Neo-Sensitabs - Carbapenemases/MBL Confirmative Identification pack and polymerase chain reaction (PCR) for detecting the blaNDM-1 gene. Among the 105 isolates, the MHT identified 100 isolates as carbapenemase producers. In the five isolates negative for the MHT, four were found to produce MBLs by the Neo-Sensitabs. The Neo-Sensitabs did not have any false negatives when compared against the PCR. The MHT can give false negative results, which lead to failure in detecting the carbapenemase producers. Also considering the other pitfalls of the MHT, the Neo-Sensitabs--Carbapenemases/MBL Confirmative Identification pack could be a more efficient alternative for detection of carbapenemase production in Gram-negative bacteria.
False belief and verb non-factivity: a common neural basis?
Cheung, Him; Chen, Lan; Szeto, Ching-Yee; Feng, Gangyi; Lu, Guangming; Zhang, Zhiqiang; Zhu, Zude; Wang, Suiping
2012-03-01
Using fMRI, the present study compares the brain activation underlying false belief thinking induced by pictorial, nonverbal material to that instigated by strong non-factive verbs in a sample of adult Chinese speakers. These verbs obligatorily negate their complements which describe the mind content of the sentence agent, and thus may activate part of the false belief network. Some previous studies have shown a behavioral correlation between verb non-factivity/false complementation and conventional false belief but corresponding neural evidence is lacking. Our results showed that the non-factive grammar and false belief commonly implicated the right temporo-parietal junction (TPJ), which had been shown by past studies to play a role in general mentalizing. Regions that were unique to nonverbal false belief were the left TPJ and right middle frontal gyrus (MFG), whereas the unique regions for the non-factive grammar were the left inferior frontal gyrus (IFG) and right superior temporal gyrus (STG). Hence, conventional nonverbal false belief and verb non-factivity have both shared and unique neural representations. Copyright © 2011 Elsevier B.V. All rights reserved.
Østergaard, Mia L; Nielsen, Kristina R; Albrecht-Beste, Elisabeth; Konge, Lars; Nielsen, Michael B
2018-01-01
This study aimed to develop a test with validity evidence for abdominal diagnostic ultrasound with a pass/fail-standard to facilitate mastery learning. The simulator had 150 real-life patient abdominal scans of which 15 cases with 44 findings were selected, representing level 1 from The European Federation of Societies for Ultrasound in Medicine and Biology. Four groups of experience levels were constructed: Novices (medical students), trainees (first-year radiology residents), intermediates (third- to fourth-year radiology residents) and advanced (physicians with ultrasound fellowship). Participants were tested in a standardized setup and scored by two blinded reviewers prior to an item analysis. The item analysis excluded 14 diagnoses. Both internal consistency (Cronbach's alpha 0.96) and inter-rater reliability (0.99) were good and there were statistically significant differences (p < 0.001) between all four groups, except the intermediate and advanced groups (p = 1.0). There was a statistically significant correlation between experience and test scores (Pearson's r = 0.82, p < 0.001). The pass/fail-standard failed all novices (no false positives) and passed all advanced (no false negatives). All intermediate participants and six out of 14 trainees passed. We developed a test for diagnostic abdominal ultrasound with solid validity evidence and a pass/fail-standard without any false-positive or false-negative scores. • Ultrasound training can benefit from competency-based education based on reliable tests. • This simulation-based test can differentiate between competency levels of ultrasound examiners. • This test is suitable for competency-based education, e.g. mastery learning. • We provide a pass/fail standard without false-negative or false-positive scores.
Predictors of false negative sentinel lymph node biopsy in trunk and extremity melanoma.
Sinnamon, Andrew J; Neuwirth, Madalyn G; Bartlett, Edmund K; Zaheer, Salman; Etherington, Mark S; Xu, Xiaowei; Elder, David E; Czerniecki, Brian J; Fraker, Douglas L; Karakousis, Giorgos C
2017-12-01
Nodal recurrence following negative sentinel lymph node biopsy (SLNB) for melanoma is known as false-negative (FN) SLNB. Risk factors for FN SLNB among patients with trunk and extremity melanoma have not been well-defined. After retrospective review, SLNB procedures were classified FN, true positive (TP; positive SLNB), or true negative (TN; negative SLNB without recurrence). Factors associated with high false negative rate (FNR) and low negative predictive value (NPV) were identified by comparing FNs to TPs and TNs, respectively. Survival was evaluated using Kaplan-Meier methods. Of 1728 patients, 234 were TP and 37 were FN for overall FNR of 14% and NPV of 97.5%. Age ≥65 years was independently associated with high FNR (FNR 20% in this group). Breslow thickness >1 mm and ulceration were independently associated with low NPV. Among patients with ulcerated tumors >4 mm, NPV was 88%. Median time to recurrence for FNs was 13 months. Among patients with primary melanomas ≤2 mm in depth, overall and distant disease-free survival were significantly shorter with FN SLNB than TP SLNB. Older age is associated with increased FNR; patients with thick, ulcerated lesions should be considered for increased nodal surveillance after negative SLNB given low NPV in this group. © 2017 Wiley Periodicals, Inc.
Is screening with digital imaging using one retinal view adequate?
Herbert, H M; Jordan, K; Flanagan, D W
2003-05-01
To compare the detection of diabetic retinopathy from digital images with slit-lamp biomicroscopy, and to determine whether British Diabetic Association (BDA) screening criteria are attained (>80% sensitivity, >95% specificity, &<5% technical failure). Diabetics referred for screening were studied in a prospective fashion. A single 45 degrees fundus image was obtained using the nonmydriatic digital camera. Each patient subsequently underwent slit-lamp biomicroscopy and diabetic retinopathy grading by a consultant ophthalmologist. Diabetic retinopathy and maculopathy was graded according to the Early Treatment of Diabetic Retinopathy Study. A total of 145 patients (288 eyes) were identified for screening. Of these, 26% of eyes had diabetic retinopathy, and eight eyes (3%) had sight-threatening diabetic retinopathy requiring treatment. The sensitivity for detection of any diabetic retinopathy was 38% and the specificity 95%. There was a 4% technical failure rate. There were 42/288 false negatives and 10/288 false positives. Of the 42 false negatives, 18 represented diabetic maculopathy, 20 represented peripheral diabetic retinopathy and four eyes had both macular and peripheral changes. Three eyes in the false-negative group (1% of total eyes) had sight-threatening retinopathy. There was good concordance between the two consultants (79% agreement on slit-lamp biomicroscopy and 84% on digital image interpretation). The specificity value and technical failure rate compare favourably with BDA guidelines. The low sensitivity for detection of any retinopathy reflects failure to detect minimal maculopathy and retinopathy outside the 45 degrees image. This could be improved by an additional nasal image and careful evaluation of macular images with a low threshold for slit-lamp biomicroscopy if image quality is poor.
Antituberculosis IgG Antibodies as a Marker of Active Mycobacterium tuberculosis Disease
Welch, Ryan J.; Lawless, Kathleen M.
2012-01-01
Anti-Mycobacterium tuberculosis IgG antibodies may aid in the diagnosis of active M. tuberculosis disease. We studied whether anti-M. tuberculosis IgG antibodies are elevated in active M. tuberculosis disease and assessed factors contributing to false-positive and -negative results. A retrospective study of 2,150 individuals tested by the QuantiFERON-TB Gold In-Tube (QFT-GIT) assay was conducted at the University of Utah, ARUP Laboratories, November 2008 to December 2010. All samples were tested with the InBios Active TbDetect antituberculosis (anti-TB) IgG antibody assay. Of 1,044 patients with a positive QFT-GIT, 59 (5.7%) were positive for M. tuberculosis antibodies. Fourteen of 1,106 (1.3%) with a negative or indeterminate QFT-GIT were positive for M. tuberculosis antibodies. M. tuberculosis antibody tests were positive in 61.5% with confirmed active M. tuberculosis disease and other mycobacterial infections. Over half of the false-negative M. tuberculosis antibody tests occurred in patients ≥90 years of age. False positives were seen in 12.9% of autoimmune patients. The odds ratio of being positive by the QFT-GIT and the InBios TB IgG assay increased with confirmed M. tuberculosis disease or highly suspected M. tuberculosis disease and was 86.7 (95% confidence interval [CI], 34.4 to 218.5) in these two groups compared to patients negative by both tests. Although anti-M. tuberculosis antibodies can be detected in patients with active M. tuberculosis disease, caution should be used with patients where immunoglobulin levels may be decreased or patients with autoantibodies. PMID:22301692
Landry, Marie L.; Eid, Tore; Bannykh, Serguei; Major, Eugene
2009-01-01
Genome amplification methods such as polymerase chain reaction (PCR) have revolutionized our ability to detect viruses in spinal fluids of patients with neurologic diseases. It is not as well appreciated among clinicians that PCR protocols, quality assurance, and technical expertise vary significantly among laboratories. In a multi-laboratory blinded study of herpes simplex virus PCR, the most widely used and best validated CSF PCR assay, low-level positives were often missed and false positives were not uncommon [Schloss L, van Loon AM, Cinque P, Cleator G, Echevarria JM, Falk KI, et al. An international external quality assessment of nucleic acid amplification of herpes simplex virus. J Clin Virol 2003;28(2):175–85]. In addition, genome variability and mutations, which are increasingly recognized for a number of different viruses, can lead to falsely low or negative results. Both clinicians and laboratories must recognize the limitations of PCR, since misleading results may have serious consequences. We present here a case of a rapidly progressive, fatal neurologic illness in a young mother, whose CSF JCV DNA PCR at a reference laboratory was falsely negative. Ultimately, brain biopsy established the diagnosis of progressive multifocal leukoencephalopathy (PML). Repeat PCR testing of the same CSF targeting a different region of the genome yielded a high positive result. PMID:18701345
El-Sayed, Abdulrahman M.; Lauderdale, Diane S.; Galea, Sandro
2010-01-01
Objective Data about Arab-Americans, a growing ethnic minority, is not routinely collected in vital statistics, registry, or administrative data in the US. The difficulty in identifying Arab-Americans using publicly available data sources is a barrier to health research about this group. Here, we validate an empirically-based, probabilistic Arab name algorithm (ANA) for identifying Arab-Americans in health research. Design We used data from all Michigan birth certificates between 2000-2005. Fathers’ surnames and mothers’ maiden names were coded as Arab or non-Arab according to the ANA. We calculated sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) of Arab ethnicity inferred using the ANA as compared to self-reported Arab ancestry. Results State-wide, the ANA had a specificity of 98.9%, a sensitivity of 50.3%, a PPV of 57.0%, and a NPV of 98.6%. Both the false positive and false negative rates were higher among men than among women. As the concentration of Arab-Americans in a study locality increased, the ANA false positive rate increased and false-negative rate decreased. Conclusion The ANA is highly specific but only moderately sensitive as a means of detecting Arab ancestry. Future research should compare health characteristics among Arab-American populations defined by Arab ancestry and those defined by the ANA. PMID:20845117
Ma, C; Wang, X; Shao, M; Zhao, L; Jiawei, X; Wu, Z; Wang, H
2015-06-01
Aim of the present study was to investigate the usefulness of 18F-FDG SPECT/CT in differentiated thyroid cancer (DTC) with elevated serum thyroglobulin (Tg) but negative iodine-131 scan. This retrospective review of patients with DTC recurrence who had 18F-FDG SPECT/CT and 18F-FDG PET/CT for elevated serum Tg but negative iodine-131 scan (March 2007-October 2012). After total thyroidectomy followed by radioiodine ablation, 86 consecutive patients with elevated Tg levels underwent 18F-FDG SPECT/CT or 18F-FDG PET/CT. Of these, 45 patients had 18F-FDG SPECT/CT, the other 41 patients had 18F-FDG PET/CT 3-4weeks after thyroid hormone withdrawal. The results of 18F-FDG PET/CT and SPECT/CT were correlated with patient follow-up information, which included the results from subsequent imaging modalities such as neck ultrasound, MRI and CT, Tg levels, and histologic examination of surgical specimens. The diagnostic accuracy of the two imaging modalities was evaluated. In 18F-FDG SPECT/CT scans, 24 (24/45) patients had positive findings, 22 true positive in 24 patients, false positive in 2 patients, true-negative and false-negative in 6, 15 patients, respectively. The overall sensitivity, specificity, and accuracy of 18F-FDG SPECT/CT were 59.5%, 75% and 62.2%, respectively. Twenty six patients had positive findings on 18F-FDG PET/CT scans, 23 true positive in 26 (26/41) patients, false positive in 3 patients, true-negative and false-negative in 9, 6 patients, respectively. The overall sensitivity, specificity, and accuracy of 18F-FDG PET/CT were 79.3%, 81.8% and 78.1%, respectively. Clinical management changed for 13 (29%) of 45 patients by 18F-FDG SPECT/CT, 14 (34%) of 41 patients by 18F-FDG PET/CT including surgery, radiation therapy, or multikinase inhibitor. Based on the retrospective analysis of 86 patients, 18F-FDG SPECT/CT has lower sensitivity in the diagnosis of DTC recurrence with elevated Tg and negative iodine-131scan to 18F-FDG PET/CT. The clinical application of FDG SPECT/CT is then limited and cannot replace PET/CT.
Joyce, K M; McInerney, N M; Piggott, R P; Martin, F; Jones, D M; Hussey, A J; Kerin, M J; Kelly, J L; Regan, P J
2017-11-01
Sentinel lymph node biopsy (SLNB) is a standard method for determining the pathologic status of the regional lymph nodes. The aim of our study was to determine the incidence and clinicopathologic factors predictive of SLN positivity, and to evaluate the prognostic importance of SLNB in patients with cutaneous melanoma. We performed a retrospective analysis of a prospectively maintained database of all patients who underwent SLNB for primary melanoma at our institution from 2005 to 2012. Statistical analysis was performed using χ 2 and Fischer exact test. In total, 318 patients underwent SLNB, of which 65 were for thin melanoma (≤1 mm). There were 36 positive SLNB, 278 negative SLNB and in four cases the SLN was not located. The incidence rate for SLNB was 11.3% overall and 1.5% in thin melanomas alone. Statistical analysis identified Breslow thickness >1 mm (P = 0.006), Clark level ≥ IV (P = 0.004) and age <75 years (P = 0.035) as the strongest predictors of SLN positivity. Our overall false negativity rate was 20% (9/45) with one case of false-negative SLNB in thin melanomas. Breslow thickness of the primary tumour remains the strongest predictor of SLN positivity. Our findings point to a possible limited role for SLNB in thin melanoma due to its low positivity rate, associated false-negative rate and related morbidity.
Levenback, Charles F.; Ali, Shamshad; Coleman, Robert L.; Gold, Michael A.; Fowler, Jeffrey M.; Judson, Patricia L.; Bell, Maria C.; De Geest, Koen; Spirtos, Nick M.; Potkul, Ronald K.; Leitao, Mario M.; Bakkum-Gamez, Jamie N.; Rossi, Emma C.; Lentz, Samuel S.; Burke, James J.; Van Le, Linda; Trimble, Cornelia L.
2012-01-01
Purpose To determine the safety of sentinel lymph node biopsy as a replacement for inguinal femoral lymphadenectomy in selected women with vulvar cancer. Patients and Methods Eligible women had squamous cell carcinoma, at least 1-mm invasion, and tumor size ≥ 2 cm and ≤ 6 cm. The primary tumor was limited to the vulva, and there were no groin lymph nodes that were clinically suggestive of cancer. All women underwent intraoperative lymphatic mapping, sentinel lymph node biopsy, and inguinal femoral lymphadenectomy. Histologic ultra staging of the sentinel lymph node was prescribed. Results In all, 452 women underwent the planned procedures, and 418 had at least one sentinel lymph node identified. There were 132 node-positive women, including 11 (8.3%) with false-negative nodes. Twenty-three percent of the true-positive patients were detected by immunohistochemical analysis of the sentinel lymph node. The sensitivity was 91.7% (90% lower confidence bound, 86.7%) and the false-negative predictive value (1-negative predictive value) was 3.7% (90% upper confidence bound, 6.1%). In women with tumor less than 4 cm, the false-negative predictive value was 2.0% (90% upper confidence bound, 4.5%). Conclusion Sentinel lymph node biopsy is a reasonable alternative to inguinal femoral lymphadenectomy in selected women with squamous cell carcinoma of the vulva. PMID:22753905
False-negative syphilis treponemal enzyme immunoassay results in an HIV-infected case-patient.
Katz, Alan R; Komeya, Alan Y; Tomas, Juval E
2017-06-01
We present a case report of a false-negative syphilis treponemal enzyme immunoassay test result in an HIV-infected male. While treponemal tests are widely considered to be more sensitive and specific than non-treponemal tests, our findings point to potential challenges using the reverse sequence syphilis screening algorithm.
Hocagil, Hilal; Hocagil, Abdullah Cüneyt; Karacabey, Sinan; Akkaya, Tuğba; Şimşek, Gözde; Sanrı, Erkman
2015-09-01
This study aimed to discuss the effectiveness of Pneumoscan working with micropower impulse radar (MIR) technology in diagnosing pneumothorax (PTX) in the emergency department. Patients with suspicion of PTX and indication for thorax tomography (CT) were included into the study. Findings of the Thorax CT were compared with the results of Pneumoscan. Chi-square and Fisher's exact tests were used in categorical variables. One hundred and fifteen patients were included into the study group; twelve patients presented with PTX diagnosed by CT, 10 of which were detected by Pneumoscan. Thirty-six true negative results, sixty-seven false positive results, and two false negative results were obtained, which resulted in an overall sensitivity of 83.3%, specificity of 35.0% for Pneumoscan. There was no statistically significant difference between the effectiveness of Pneumoscan and CT on the detection of PTX (p=0.33). There was no difference between the size of PTX diagnosed by CT and PTX diagnosed by Pneumoscan (p=0.47). There was no statistically significant difference between Pneumoscan and CT on detecting the localisation of the PTX (p=1.00). For the 10 cases diagnosed by Pneumoscan, mean chest wall thickness was determined as 50.3 mm while mean chest wall thickness for two false negatives diagnosed by Pneumoscan was 56.5 mm. However, no statistically significant difference was found between the chest wall thickness and the effectiveness of Pneumoscan on the detection of the PTX (p=0.77). Among sixty-seven false positives diagnosed by Pneumoscan, 46.3% had additional medical signs such as bronchiectasis, pulmonary consolidation, pulmonary edema or pulmonary tumor when they had a reading with CT. The relationship between having additional medical signs at the reading with CT and the effectiveness of Pneumoscan on the detection of the PTX was investigated and no significant difference was found (p=0.472). Using Pneumoscan to detect PTX is controversial since the device has a high false positive ratio. Wherein, false positive diagnosis can cause unjustifiable chest tube insertion. In addition, the device failed to show the size of the PTX, and therefore, it did not aid in determining the treatment and prognosis on contrary to traditional diagnostic methods. The findings could not demonstrate that the device was efficient in emergency care. Further studies and increasing experience may change this outcome in upcoming years.
Ferreira, Bruno G.; Falcioni, Renan; Guedes, Lubia M.; Avritzer, Sofia C.; Antunes, Werner C.; Souza, Luiz A.; Isaias, Rosy M.S.
2016-01-01
Polyethylene glycol (PEG) is a low-cost and advantageous embedding medium, which maintains the majority of cell contents unaltered during the embedding process. Some hard or complex plant materials are better embedded in PEG than in other usual embedding media. However, the histochemical tests for phenolics and lignins in PEG-embedded plant tissues commonly result in false negatives. We hypothesize that these false negatives should be prevented by the use of distinct fixatives, which should avoid the bonds between PEG and phenols. Novel protocols for phenolics and flavanols detection are efficiently tested, with fixation of the samples in ferrous sulfate and formalin or in caffeine and sodium benzoate, respectively. The differentiation of lignin types is possible in safranin-stained sections observed under fluorescence. The Maule’s test faultlessly distinguishes syringyl-rich from guaiacyl- and hydroxyphenyl-rich lignins in PEG-embedded material under light microscopy. Current hypothesis is corroborated, that is, the adequate fixation solves the false-negative results, and the new proposed protocols fill up some gaps on the detection of phenolics and lignins. PMID:28117630
Monier, I; Blondel, B; Ego, A; Kaminiski, M; Goffinet, F; Zeitlin, J
2015-03-01
To assess the proportion of small for gestational age (SGA) and normal birthweight infants suspected of fetal growth restriction (FGR) during pregnancy, and to investigate obstetric and neonatal outcomes by suspicion of FGR and SGA status at birth. Population-based study. All French maternity units in 2010. Representative sample of singleton births (n = 14,100). We compared SGA infants with a birthweight of less than the 10th percentile suspected of FGR, defined as mention of FGR in medical charts (true positives), non-SGA infants suspected of FGR (false positives), SGA infants without suspicion of FGR (false negatives) and non-SGA infants without suspicion of FGR (true negatives). Multivariable analyses were adjusted for maternal and neonatal characteristics hypothesised to affect closer surveillance for FGR and our outcomes. Obstetric management (caesarean, provider-initiated preterm and early term delivery) and neonatal outcomes (late fetal death, preterm birth, Apgar score, resuscitation at birth). 21.7% of SGA infants (n = 265) and 2.1% of non-SGA infants (n = 271) were suspected of FGR during pregnancy. Compared with true negatives, provider-initiated preterm deliveries were higher for true and false positives (adjusted risk ratio [aRR], 6.1 [95% CI, 3.8-9.8] and 4.6 [95% CI, 3.2-6.7]), but not for false negatives (aRR, 1.1 [95% CI, 0.6-1.9]). Neonatal outcomes were not better for SGA infants if FGR was suspected. Antenatal suspicion of FGR among SGA infants was low and one-half of infants suspected of FGR were not SGA. The increased risk of provider-initiated delivery observed in non-SGA infants suspected of FGR raises concerns about the iatrogenic consequences of screening. © 2014 The Authors BJOG An International Journal of Obstetrics and Gynaecology published by John Wiley & Sons Ltd on behalf of Royal College of Obstetricians and Gynaecologists.
Neural network for photoplethysmographic respiratory rate monitoring
NASA Astrophysics Data System (ADS)
Johansson, Anders
2001-10-01
The photoplethysmographic signal (PPG) includes respiratory components seen as frequency modulation of the heart rate (respiratory sinus arrhythmia, RSA), amplitude modulation of the cardiac pulse, and respiratory induced intensity variations (RIIV) in the PPG baseline. The aim of this study was to evaluate the accuracy of these components in determining respiratory rate, and to combine the components in a neural network for improved accuracy. The primary goal is to design a PPG ventilation monitoring system. PPG signals were recorded from 15 healthy subjects. From these signals, the systolic waveform, diastolic waveform, respiratory sinus arrhythmia, pulse amplitude and RIIV were extracted. By using simple algorithms, the rates of false positive and false negative detection of breaths were calculated for each of the five components in a separate analysis. Furthermore, a simple neural network (NN) was tried out in a combined pattern recognition approach. In the separate analysis, the error rates (sum of false positives and false negatives) ranged from 9.7% (pulse amplitude) to 14.5% (systolic waveform). The corresponding value of the NN analysis was 9.5-9.6%.
Buratto, Luciano Grüdtner; Zimmermann, Nicolle; Ferré, Perrine; Joanette, Yves; Fonseca, Rochele Paz; Stein, Lilian Milnitsky
2014-10-01
Previous research has attributed to the right hemisphere (RH) a key role in eliciting false memories to visual emotional stimuli. These results have been explained in terms of two right-hemisphere properties: (i) that emotional stimuli are preferentially processed in the RH and (ii) that visual stimuli are represented more coarsely in the RH. According to this account, false emotional memories are preferentially produced in the RH because emotional stimuli are both more strongly and more diffusely activated during encoding, leaving a memory trace that can be erroneously reactivated by similar but unstudied emotional items at test. If this right-hemisphere hypothesis is correct, then RH damage should result in a reduction in false memories to emotional stimuli relative to left-hemisphere lesions. To investigate this possibility, groups of right-brain-damaged (RBD, N=15), left-brain-damaged (LBD, N=15) and healthy (HC, N=30) participants took part in a recognition memory experiment with emotional (negative and positive) and non-emotional pictures. False memories were operationalized as incorrect responses to unstudied pictures that were similar to studied ones. Both RBD and LBD participants showed similar reductions in false memories for negative pictures relative to controls. For positive pictures, however, false memories were reduced only in RBD patients. The results provide only partial support for the right-hemisphere hypothesis and suggest that inter-hemispheric cooperation models may be necessary to fully account for false emotional memories. Copyright © 2014 Elsevier Inc. All rights reserved.
Risk management and precaution: insights on the cautious use of evidence.
Hrudey, Steve E; Leiss, William
2003-01-01
Risk management, done well, should be inherently precautionary. Adopting an appropriate degree of precaution with respect to feared health and environmental hazards is fundamental to risk management. The real problem is in deciding how precautionary to be in the face of inevitable uncertainties, demanding that we understand the equally inevitable false positives and false negatives from screening evidence. We consider a framework for detection and judgment of evidence of well-characterized hazards, using the concepts of sensitivity, specificity, positive predictive value, and negative predictive value that are well established for medical diagnosis. Our confidence in predicting the likelihood of a true danger inevitably will be poor for rare hazards because of the predominance of false positives; failing to detect a true danger is less likely because false negatives must be rarer than the danger itself. Because most controversial environmental hazards arise infrequently, this truth poses a dilemma for risk management. PMID:14527835
Can integrated 18F-FDG PET/MR replace sentinel lymph node resection in malignant melanoma?
Schaarschmidt, Benedikt Michael; Grueneisen, Johannes; Stebner, Vanessa; Klode, Joachim; Stoffels, Ingo; Umutlu, Lale; Schadendorf, Dirk; Heusch, Philipp; Antoch, Gerald; Pöppel, Thorsten Dirk
2018-06-06
To compare the sensitivity and specificity of 18F-fluordesoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT), 18F-FDG PET/magnetic resonance (18F-FDG PET/MR) and 18F-FDG PET/MR including diffusion weighted imaging (DWI) in the detection of sentinel lymph node metastases in patients suffering from malignant melanoma. Fifty-two patients with malignant melanoma (female: n = 30, male: n = 22, mean age 50.5 ± 16.0 years, mean tumor thickness 2.28 ± 1.97 mm) who underwent 18F-FDG PET/CT and subsequent PET/MR & DWI for distant metastasis staging were included in this retrospective study. After hybrid imaging, lymphoscintigraphy including single photon emission computed tomography/CT (SPECT/CT) was performed to identify the sentinel lymph node prior to sentinel lymph node biopsy (SLNB). In a total of 87 sentinel lymph nodes in 64 lymph node basins visible on SPECT/CT, 17 lymph node metastases were detected by histopathology. In separate sessions PET/CT, PET/MR, and PET/MR & DWI were assessed for sentinel lymph node metastases by two independent readers. Discrepant results were resolved in a consensus reading. Sensitivities, specificities, positive predictive values and negative predictive values were calculated with histopathology following SPECT/CT guided SLNB as a reference standard. Compared with histopathology, lymph nodes were true positive in three cases, true negative in 65 cases, false positive in three cases and false negative in 14 cases in PET/CT. PET/MR was true positive in four cases, true negative in 63 cases, false positive in two cases and false negative in 13 cases. Hence, we observed a sensitivity, specificity, positive predictive value and negative predictive value of 17.7, 95.6, 50.0 and 82.3% for PET/CT and 23.5, 96.9, 66.7 and 82.3% for PET/MR. In DWI, 56 sentinel lymph node basins could be analyzed. Here, the additional analysis of DWI led to two additional false positive findings, while the number of true positive findings could not be increased. In conclusion, integrated 18F-FDG PET/MR does not reliably differentiate N-positive from N-negative melanoma patients. Additional DWI does not increase the sensitivity of 18F-FDG PET/MR. Hence, sentinel lymph node biopsy cannot be replaced by 18F-FDG-PE/MR or 18F-FDG-PET/CT.
Johnson, Susan L; Tabaei, Bahman P; Herman, William H
2005-02-01
To simulate the outcomes of alternative strategies for screening the U.S. population 45-74 years of age for type 2 diabetes. We simulated screening with random plasma glucose (RPG) and cut points of 100, 130, and 160 mg/dl and a multivariate equation including RPG and other variables. Over 15 years, we simulated screening at intervals of 1, 3, and 5 years. All positive screening tests were followed by a diagnostic fasting plasma glucose or an oral glucose tolerance test. Outcomes include the numbers of false-negative, true-positive, and false-positive screening tests and the direct and indirect costs. At year 15, screening every 3 years with an RPG cut point of 100 mg/dl left 0.2 million false negatives, an RPG of 130 mg/dl or the equation left 1.3 million false negatives, and an RPG of 160 mg/dl left 2.8 million false negatives. Over 15 years, the absolute difference between the most sensitive and most specific screening strategy was 4.5 million true positives and 476 million false-positives. Strategies using RPG cut points of 130 mg/dl or the multivariate equation every 3 years identified 17.3 million true positives; however, the equation identified fewer false-positives. The total cost of the most sensitive screening strategy was $42.7 billion and that of the most specific strategy was $6.9 billion. Screening for type 2 diabetes every 3 years with an RPG cut point of 130 mg/dl or the multivariate equation provides good yield and minimizes false-positive screening tests and costs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dana Kelly; Kurt Vedros; Robert Youngblood
This paper examines false indication probabilities in the context of the Mitigating System Performance Index (MSPI), in order to investigate the pros and cons of different approaches to resolving two coupled issues: (1) sensitivity to the prior distribution used in calculating the Bayesian-corrected unreliability contribution to the MSPI, and (2) whether (in a particular plant configuration) to model the fuel oil transfer pump (FOTP) as a separate component, or integrally to its emergency diesel generator (EDG). False indication probabilities were calculated for the following situations: (1) all component reliability parameters at their baseline values, so that the true indication ismore » green, meaning that an indication of white or above would be false positive; (2) one or more components degraded to the extent that the true indication would be (mid) white, and “false” would be green (negative) or yellow (negative) or red (negative). In key respects, this was the approach taken in NUREG-1753. The prior distributions examined were the constrained noninformative (CNI) prior used currently by the MSPI, a mixture of conjugate priors, the Jeffreys noninformative prior, a nonconjugate log(istic)-normal prior, and the minimally informative prior investigated in (Kelly et al., 2010). The mid-white performance state was set at ?CDF = ?10 ? 10-6/yr. For each simulated time history, a check is made of whether the calculated ?CDF is above or below 10-6/yr. If the parameters were at their baseline values, and ?CDF > 10-6/yr, this is counted as a false positive. Conversely, if one or all of the parameters are set to values corresponding to ?CDF > 10-6/yr but that time history’s ?CDF < 10-6/yr, this is counted as a false negative indication. The false indication (positive or negative) probability is then estimated as the number of false positive or negative counts divided by the number of time histories (100,000). Results are presented for a set of base case parameter values, and three sensitivity cases in which the number of FOTP demands was reduced, along with the Birnbaum importance of the FOTP.« less
Experience with a tuberculosis antigen test in Rhodesia.
Cookson, J B; Cruickshank, J G; Ellis, B P
1977-10-01
Experience with a new serological method for the diagnosis of tuberculosis is reported in a predominantly black population. We have found that in only 69% of 167 patients was there agreement between serology and the presence or absence of tuberculosis. Both false positive and false negative results were common. Of 47 healthy controls, 80% were positive. These results are less satisfactory than previous studies but differences in the reading of the results seems an unlikely explanation. Differences in the populations studied may be an important factor.
The psychological impact of a false-positive screening mammogram in Barcelona.
Espasa, Rebecca; Murta-Nascimento, Cristiane; Bayés, Ramón; Sala, Maria; Casamitjana, Montserrat; Macià, Francesc; Castells, Xavier
2012-12-01
The purpose of this study was to ascertain the psychological impact of mammographic screening for women who receive negative results and for those who need additional non-invasive and invasive complementary investigations to exclude breast cancer (false positives). One hundred fifty women who attended a breast cancer screening programme in Barcelona, aged 50-69 years, were included in this study: 50 with negative results and 100 with false positive mammograms (50 underwent non-invasive and 50 underwent invasive complementary investigations). Participants worried little until they underwent mammography, but worries increased when a telephone call notified the women of the need for further testing. A substantial proportion of women requiring further assessment reported that they were at least somewhat worried about having breast cancer throughout the screening process (P < 0.0001). Nevertheless, levels of anxiety and depression, measured by the Hospital Anxiety and Depression Scale, showed no statistically significant differences among the three groups. In conclusion, although the women showed no psychological morbidity, there is a substantial psychological response in those with an abnormal screening mammogram.
Hakim, R; Black, P M
1998-01-01
After the initial description of normal pressure hydrocephalus (NPH) and its clinical triad, there has been a continuous interest from clinicians and researchers to set different diagnostic criteria that would make the selection of candidates for shunt surgery easier and more precise. A preliminary group of 12 patients was given a diagnosis of idiopathic normal pressure hydrocephalus by clinical and radiologic criteria. Each patient underwent two different tests: a magnetic resonance imaging-cerebrospinal fluid (MRI-CSF) flow study and a lumbo-ventricular perfusion test. The purpose was to compare the correlation of the results obtained with these tests and the clinical results obtained after CSF diversion. Eleven patients were given shunts and one was managed with lumbar punctures. One year after treatment, 10 of the 12 patients had improved with good results. The MRI-CSF flow studies were reliable in six patients; there were five false negatives and one false positive. The lumbo-ventricular perfusion test showed reliability in nine patients; there were two false negatives and one false positive. In only three patients were the results of both of these tests in accordance with the outcome. Even though there are few patients in this study so far, the data suggests that at the present time the most predictive guides for the diagnosis of NPH and its outcome after shunting are the clinical criteria and the radiological findings in computed tomography (CT) and/or MRI rather than lumbo-ventricular perfusion and CSF flow studies.
Do false belief and verb non-factivity share similar neural circuits?
Chen, Lan; Cheung, Him; Szeto, Ching-Yee; Zhu, Zude; Wang, Suiping
2012-02-21
The present study investigates whether the complement falsity elicited by strong non-factive verbs and the false belief activated by a standard nonverbal false belief task produce similar electrophysiological activities in the brain. The hypothesis is based on the notion that both complement falsity and false belief involve decoupling a false mental representation from reality. Some previous studies have reported a behavioral correlation between children's false belief reasoning and interpretation of strong non-factive verbs together with their false complements, but a neural basis for this correlation has not been found. Our event-related potential (ERP) results with normal adults showed that both nonverbal false belief and strong non-factive verb comprehension elicited a negative late slow waveform divergence compared to their respective baselines. Although these slow waves due to the two types of stimuli had slightly different scalp distributions, both were regarded as reflecting primarily frontal activation. Such ERP similarity provides evidence for a common neural basis shared by nonverbal false belief reasoning and comprehension of strong non-factive verbs. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Padoan, R; Genoni, S; Moretti, E; Seia, M; Giunta, A; Corbetta, C
2002-01-01
A study was performed on the delayed diagnosis of cystic fibrosis (CF) in infants who had false-negative results in a neonatal screening programme. The genetic and clinical features of false-negative infants in this screening programme were assessed together with the efficiency of the screening procedure in the Lombardia region. In total, 774,687 newborns were screened using a two-step immunoreactive trypsinogen (IRT) (in the years 1990-1992), IRT/IRT + delF508 (1993-1998) or IRT/IRT + polymerase chain reaction (PCR) and oligonucleotide ligation assay (OLA) protocol (1998-1999). Out of 196 CF children born in the 10 y period 15 were false negative on screening (7.6%) and molecular analysis showed a high variability in the genotypes. The cystic fibrosis transmembrane regulator (CFTR) gene mutations identified were delF508, D1152H, R1066C, R334W, G542X, N1303K, F1052V, A120T, 3849 + 10kbC --> T, 2789 + 5G --> A, 5T-12TG and the novel mutation D110E. In three patients no mutation was identified after denaturing gradient gel electrophoresis of the majority of CFTR gene exons. The clinical phenotypes of CF children diagnosed by their symptoms at different ages were very mild. None of them presented with a severe lung disease. The majority of them did not seem to have been damaged by the delayed diagnosis. The combination of IRT assay plus genotype analysis (1998-1999) appears to be a more reliable method of detecting CF than IRT measurement alone or combined with only the delF508 mutation.
Padula, Francesco; Laganà, Antonio Simone; Vitale, Salvatore Giovanni; D'Emidio, Laura; Coco, Claudio; Giannarelli, Diana; Cariola, Maria; Favilli, Alessandro; Giorlandino, Claudio
2017-05-01
Maternal age is a crucial factor in fetal aneuploidy screening, resulting in an increased rate of false-positive cases in older women and false-negative cases in younger women. The absolute risk (AR) is the simplest way to eliminate the background maternal age risk, as it represents the amount of improvement of the combined risk from the maternal background risk. The aim of this work is to assess the performance of the AR in the combined first-trimester screening for aneuploidies. A retrospective validation of the AR in the combined first-trimester screening for fetal aneuploidies, in an unselected population at Altamedica Fetal-Maternal Medical Center in Rome, between March 2007 and December 2008. Of 3845 women included in the study, we had a complete follow-up on 2984. We evaluated that an AR < 3 would individuate 22 of 23 cases of aneuploidy with a detection rate of 95.7% (95%CI 87.3-100), a false-positive rate of 8.7% (95%CI 7.7-9.7) and a false-negative rate of 4.3% (95%CI 0-12.7). In our study, the AR ameliorates the detection rate for aneuploidy. Further research and a prospective study on a larger population would help us to improve the AR in detecting most cases of aneuploidy.
Global Sensitivity Analysis with Small Sample Sizes: Ordinary Least Squares Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Michael J.; Liu, Wei; Sivaramakrishnan, Raghu
2016-12-21
A new version of global sensitivity analysis is developed in this paper. This new version coupled with tools from statistics, machine learning, and optimization can devise small sample sizes that allow for the accurate ordering of sensitivity coefficients for the first 10-30 most sensitive chemical reactions in complex chemical-kinetic mechanisms, and is particularly useful for studying the chemistry in realistic devices. A key part of the paper is calibration of these small samples. Because these small sample sizes are developed for use in realistic combustion devices, the calibration is done over the ranges of conditions in such devices, with amore » test case being the operating conditions of a compression ignition engine studied earlier. Compression ignition engines operate under low-temperature combustion conditions with quite complicated chemistry making this calibration difficult, leading to the possibility of false positives and false negatives in the ordering of the reactions. So an important aspect of the paper is showing how to handle the trade-off between false positives and false negatives using ideas from the multiobjective optimization literature. The combination of the new global sensitivity method and the calibration are sample sizes a factor of approximately 10 times smaller than were available with our previous algorithm.« less
[Applying competitive polymerase chain reaction to the detection of hepatitis B virus DNA].
Wang, Ling; Yang, Peng; Li, Shuang-qing; Xu, Shu-hui; Cao, Gui-qun; Zhang, Fa-qiang; Zhang, Mei-xia; Chen, Qing-ying; Xia, Qing-jie; Liu, Kai; Tang, Fang; Zhang, Yuan-zheng
2004-11-01
To reduce the rate of accidental false negative result in the HBV DNA PCR test on clinical serum samples. A competitive polymerase chain reaction (C-PCR) was used to decrease the false negative ratio. In the C-PCR, a constructed inner control DNA was added for co-amplification with the HBV target DNA. In a 20 microl C-PCR system, about 60 to 200 copies of inner control DNA could give apparent co-amplification signal band after electrophoresis on a 2% agarose gel. Five of 120 samples of clinical serum (4.2%) could not be amplified. C-PCR has the advantage of yielding information on false negative in the HBV DNA PCR assay of clinical serum samples.
Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L
2018-03-01
There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.
Emotion and false memory: How goal-irrelevance can be relevant for what people remember.
Van Damme, Ilse; Kaplan, Robin L; Levine, Linda J; Loftus, Elizabeth F
2017-02-01
Elaborating on misleading information concerning emotional events can lead people to form false memories. The present experiment compared participants' susceptibility to false memories when they elaborated on information associated with positive versus negative emotion and pregoal versus postgoal emotion. Pregoal emotion reflects appraisals that goal attainment or failure is anticipated but has not yet occurred (e.g., hope and fear). Postgoal emotion reflects appraisals that goal attainment or failure has already occurred (e.g., happiness and devastation). Participants watched a slideshow depicting an interaction between a couple and were asked to empathise with the protagonist's feelings of hope (positive pregoal), happiness (positive postgoal), fear (negative pregoal), or devastation (negative postgoal); in control conditions, no emotion was mentioned. Participants were then asked to reflect on details of the interaction that had occurred (true) or had not occurred (false), and that were relevant or irrelevant to the protagonist's goal. Irrespective of emotional valence, participants in the pregoal conditions were more susceptible to false memories concerning goal-irrelevant details than were participants in the other conditions. These findings support the view that pregoal emotions narrow attention to information relevant to goal pursuit, increasing susceptibility to false memories for irrelevant information.
Predicting the carcinogenicity of chemicals with alternative approaches: recent advances.
Benigni, Romualdo
2014-09-01
Alternative approaches to the rodent bioassay are necessary for early identification of problematic drugs and biocides during the development process, and are the only practicable tool for assessing environmental chemicals with no or adequate safety documentation. This review informs on: i) the traditional prescreening through genotoxicity testing; ii) an integrative approach that assesses DNA-reactivity and ability to disorganize tissues; iii) new applications of omics technologies (ToxCast/Tox21 project); iv) a pragmatic approach aimed at filling data gaps by intrapolating/extrapolating from similar chemicals (read-across, category formation). The review also approaches the issue of the concerns about false-positive and false-negative results that prevents a wider acceptance and use of alternatives. The review addresses strengths and limitations of various proposals, and concludes on the need of differential approaches to the issue of false negatives and false positives. False negatives can be eliminated or reduced below the variability of the animal assay with conservative quantitative structure-activity relationships or in vitro tests; false positives can be cleared with ad hoc mechanistically based follow-ups. This framework can permit a reduction of animal testing and a better protection of human health.
[How to manage vertigo in adult?
Vuong Chaney, Hella; Rohmer, Dominique; Charpiot, Anne
2017-11-01
The interrogation and the clinical examination are critical in the research of vertigo etiology. In the context of vertigo, the vital emergencies are of neurological and vascular origins. It is therefore necessary to be able to identify them quickly and simply. Vertigo is a symptom to relieve and the cause is to be diagnosed. Careful questioning combined with neurological examination, nystagmus study, Halmagyi test and skew deviation search are more reliable than imaging in the first 48hours to detect a stroke. There are 12% false negatives in cerebral MRI and 74% false negative in cerebral CT-scan in the first 48hours of an ischemic stroke. Labyrinth emergencies are infectious labyrinthitis, perilymphatic fistula and aeroembolism of the vestibule. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Mei, Suyu; Zhu, Hao
2015-01-26
Protein-protein interaction (PPI) prediction is generally treated as a problem of binary classification wherein negative data sampling is still an open problem to be addressed. The commonly used random sampling is prone to yield less representative negative data with considerable false negatives. Meanwhile rational constraints are seldom exerted on model selection to reduce the risk of false positive predictions for most of the existing computational methods. In this work, we propose a novel negative data sampling method based on one-class SVM (support vector machine, SVM) to predict proteome-wide protein interactions between HTLV retrovirus and Homo sapiens, wherein one-class SVM is used to choose reliable and representative negative data, and two-class SVM is used to yield proteome-wide outcomes as predictive feedback for rational model selection. Computational results suggest that one-class SVM is more suited to be used as negative data sampling method than two-class PPI predictor, and the predictive feedback constrained model selection helps to yield a rational predictive model that reduces the risk of false positive predictions. Some predictions have been validated by the recent literature. Lastly, gene ontology based clustering of the predicted PPI networks is conducted to provide valuable cues for the pathogenesis of HTLV retrovirus.
Lindquist, Kristen A.; Adebayo, Morenikeji; Barrett, Lisa Feldman
2016-01-01
Negative stimuli do not only evoke fear or disgust, but can also evoke a state of ‘morbid fascination’ which is an urge to approach and explore a negative stimulus. In the present neuroimaging study, we applied an innovative method to investigate the neural systems involved in typical and atypical conceptualizations of negative images. Participants received false feedback labeling their mental experience as fear, disgust or morbid fascination. This manipulation was successful; participants judged the false feedback correct for 70% of the trials on average. The neuroimaging results demonstrated differential activity within regions in the ‘neural reference space for discrete emotion’ depending on the type of feedback. We found robust differences in the ventrolateral prefrontal cortex, the dorsomedial prefrontal cortex and the lateral orbitofrontal cortex comparing morbid fascination to control feedback. More subtle differences in the dorsomedial prefrontal cortex and the lateral orbitofrontal cortex were also found between morbid fascination feedback and the other emotion feedback conditions. This study is the first to forward evidence about the neural representation of the experimentally unexplored state of morbid fascination. In line with a constructionist framework, our findings suggest that neural resources associated with the process of conceptualization contribute to the neural representation of this state. PMID:26180088
Speich, Benjamin; Ali, Said M; Ame, Shaali M; Albonico, Marco; Utzinger, Jürg; Keiser, Jennifer
2015-02-05
An accurate diagnosis of soil-transmitted helminthiasis is important for individual patient management, for drug efficacy evaluation and for monitoring control programmes. The Kato-Katz technique is the most widely used method detecting soil-transmitted helminth eggs in faecal samples. However, detailed analyses of quality control, including false-positive and faecal egg count (FEC) estimates, have received little attention. Over a 3-year period, within the frame of a series of randomised controlled trials conducted in Pemba, United Republic of Tanzania, 10% of randomly selected Kato-Katz thick smears were re-read for Trichuris trichiura and Ascaris lumbricoides eggs. In case of discordant result (i.e. positive versus negative) the slides were re-examined a third time. A result was assumed to be false-positive or false-negative if the result from the initial reading did not agree with the quality control as well as the third reading. We also evaluated the general agreement in FECs between the first and second reading, according to internal and World Health Organization (WHO) guidelines. From the 1,445 Kato-Katz thick smears subjected to quality control, 1,181 (81.7%) were positive for T. trichiura and 290 (20.1%) were positive for A. lumbricoides. During quality control, very low rates of false-positive results were observed; 0.35% (n = 5) for T. trichiura and 0.28% (n = 4) for A. lumbricoides. False-negative readings of Kato-Katz thick smears were obtained in 28 (1.94%) and 6 (0.42%) instances for T. trichiura and A. lumbricoides, respectively. A high frequency of discordant results in FECs was observed (i.e. 10.0-23.9% for T. trichiura, and 9.0-11.4% for A. lumbricoides). Our analyses show that the rate of false-positive diagnoses of soil-transmitted helminths is low. As the probability of false-positive results increases after examination of multiple stool samples from a single individual, the potential influence of false-positive results on epidemiological studies and anthelminthic drug efficacy studies should be determined. Existing WHO guidelines for quality control might be overambitious and might have to be revised, specifically with regard to handling disagreements in FECs.
Antunes, Bárbara; Murtagh, Fliss; Bausewein, Claudia; Harding, Richard; Higginson, Irene J
2015-02-01
Depression is common among patients with advanced disease but often difficult to detect. To assess the Palliative care Outcome Scale (POS) (10 items) against the Geriatric Depression Scale (GDS)-10 total score and the Hospital Anxiety and Depression Scale (HADS)-Depression subscale total score and determine if the POS has appropriate items to screen for depression among people with advanced disease. This was a secondary analysis performed on five studies. Four psychometric properties were assessed: data quality, scaling assumptions, acceptability, and internal consistency (reliability). Receiver operating characteristic (ROC) curves were used to determine the area under the curve. Sensitivity, specificity, positive and negative predictive values, false positive and negative rates, and positive and negative likelihood ratios were computed. The overall sample had 416 patients from Germany and England: 144 had cancer and 267 had nonmalignant conditions. Prevalence of depression across the sample was 17.5%. Floor and ceiling effects were rare. Cronbach's alpha coefficients for POS items 7 and 8 summed, GDS-10 and HADS-Depression items varied: 0.61 (heart failure) and 0.80 (cancer). Two items combined (Item 7-feeling depressed and Item 8-feeling good about yourself) consistently presented the highest area under the ROC curve, ranging from 0.76 (95% CI 0.60, 0.93) (Germany, lung cancer) to 0.97 (95% CI 0.91, 1.0) (heart failure), highest negative predictive value, and lowest false negative rate. For the overall sample, the cutoff 2/3 presented a negative predictive value of 89.4% (95% CI 84.7, 92.8) and false negative rate of 10.6 (95% CI 7.2, 15.3). POS items 7 and 8 summed are potentially useful to screen for depression in advanced disease populations. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
Confabulation versus experimentally induced false memories in Korsakoff patients.
Van Damme, Ilse; d'Ydewalle, Géry
2010-09-01
The present study focuses on both the clinical symptom of confabulation and experimentally induced false memories in patients suffering from Korsakoff's syndrome. Despite the vast amount of case studies of confabulating patients and studies investigating false memories in the Deese-Roediger-McDermott (DRM) paradigm, the nature of Korsakoff patients' confabulatory behaviour and its association with DRM false memories have been rarely examined. Hence, the first aim of the present study was to evaluate confabulatory responses in a large sample of chronic Korsakoff patients and matched controls by means of the Dalla Barba Confabulation Battery. Second, the association between (provoked) confabulation and the patients' DRM false recognition performance was investigated. Korsakoff patients mainly confabulated in response to questions about episodic memory and questions to which the answer was unknown. A positive association was obtained between confabulation and the tendency to accept unstudied distractor words as being old in the DRM paradigm. On the other hand, there was a negative association between confabulation and false recognition of critical lures. The latter could be attributed to the importance of strategic retrieval at delayed memory testing.
Miller, David A W; Nichols, James D; Gude, Justin A; Rich, Lindsey N; Podruzny, Kevin M; Hines, James E; Mitchell, Michael S
2013-01-01
Large-scale presence-absence monitoring programs have great promise for many conservation applications. Their value can be limited by potential incorrect inferences owing to observational errors, especially when data are collected by the public. To combat this, previous analytical methods have focused on addressing non-detection from public survey data. Misclassification errors have received less attention but are also likely to be a common component of public surveys, as well as many other data types. We derive estimators for dynamic occupancy parameters (extinction and colonization), focusing on the case where certainty can be assumed for a subset of detections. We demonstrate how to simultaneously account for non-detection (false negatives) and misclassification (false positives) when estimating occurrence parameters for gray wolves in northern Montana from 2007-2010. Our primary data source for the analysis was observations by deer and elk hunters, reported as part of the state's annual hunter survey. This data was supplemented with data from known locations of radio-collared wolves. We found that occupancy was relatively stable during the years of the study and wolves were largely restricted to the highest quality habitats in the study area. Transitions in the occupancy status of sites were rare, as occupied sites almost always remained occupied and unoccupied sites remained unoccupied. Failing to account for false positives led to over estimation of both the area inhabited by wolves and the frequency of turnover. The ability to properly account for both false negatives and false positives is an important step to improve inferences for conservation from large-scale public surveys. The approach we propose will improve our understanding of the status of wolf populations and is relevant to many other data types where false positives are a component of observations.
Finkel, Eli J; Eastwick, Paul W; Reis, Harry T
2015-02-01
In recent years, a robust movement has emerged within psychology to increase the evidentiary value of our science. This movement, which has analogs throughout the empirical sciences, is broad and diverse, but its primary emphasis has been on the reduction of statistical false positives. The present article addresses epistemological and pragmatic issues that we, as a field, must consider as we seek to maximize the scientific value of this movement. Regarding epistemology, this article contrasts the false-positives-reduction (FPR) approach with an alternative, the error balance (EB) approach, which argues that any serious consideration of optimal scientific practice must contend simultaneously with both false-positive and false-negative errors. Regarding pragmatics, the movement has devoted a great deal of attention to issues that frequently arise in laboratory experiments and one-shot survey studies, but it has devoted less attention to issues that frequently arise in intensive and/or longitudinal studies. We illustrate these epistemological and pragmatic considerations with the case of relationship science, one of the many research domains that frequently employ intensive and/or longitudinal methods. Specifically, we examine 6 research prescriptions that can help to reduce false-positive rates: preregistration, prepublication sharing of materials, postpublication sharing of data, close replication, avoiding piecemeal publication, and increasing sample size. For each, we offer concrete guidance not only regarding how researchers can improve their research practices and balance the risk of false-positive and false-negative errors, but also how the movement can capitalize upon insights from research practices within relationship science to make the movement stronger and more inclusive. PsycINFO Database Record (c) 2015 APA, all rights reserved.
Bays, Rebecca B; Zabrucky, Karen M; Gagne, Phill
2012-01-01
In the current study we examined whether prevalence information and imagery encoding influence participants' general plausibility, personal plausibility, belief, and memory ratings for suggested childhood events. Results showed decreases in general and personal plausibility ratings for low prevalence events when encoding instructions were not elaborate; however, instructions to repeatedly imagine suggested events elicited personal plausibility increases for low-prevalence events, evidence that elaborate imagery negated the effect of our prevalence manipulation. We found no evidence of imagination inflation or false memory construction. We discuss critical differences in researchers' manipulations of plausibility and imagery that may influence results of false memory studies in the literature. In future research investigators should focus on the specific nature of encoding instructions when examining the development of false memories.
Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer.
Broeren, Maarten A C; Bahçeci, Semiha; Vader, Huib L; Arents, Niek L A
2011-03-01
The diagnosis of urinary tract infection (UTI) by urine culture is time-consuming and can produce up to 60 to 80% negative results. Fast screening methods that can reduce the necessity for urine cultures will have a large impact on overall turnaround time and laboratory economics. We have evaluated the detection of bacteria and leukocytes by a new urine analyzer, the UF-1000i, to identify negative urine samples that can be excluded from urine culture. In total, 1,577 urine samples were analyzed and compared to urine culture. Urine culture showed growth of ≥10(3) CFU/ml in 939 samples (60%). Receiver operating characteristics (ROC) curves and ROC decision plots were been prepared at three different gold standard definitions of a negative urine culture: no growth, growth of bacteria at <10(4) CFU/ml, and growth of bacteria at <10(5) CFU/ml. Also, the reduction in urine cultures and the percentage of false negatives were calculated. At the most stringent gold standard definition of no growth, a chosen sensitivity of 95% resulted in a cutoff value of 26 bacteria/μl, a specificity of 43% and a reduction in urine cultures of only 20%, of which 14% were false negatives. However, at a gold standard definition of <10(5) CFU/ml and a sensitivity of 95%, the UF-1000i cutoff value was 230 bacteria/μl, the specificity was 80%, and the reduction in urine cultures was 52%, of which 0.3% were false negatives. The applicability of the UF-1000i to screen for negative urine samples strongly depends on population characteristics and the definition of a negative urine culture. In our setting, however, the low workload savings and the high percentage of false-negative results do not warrant the UF-1000i to be used as a screening analyzer.
Imaging in gynaecology: How good are we in identifying endometriomas?
Van Holsbeke, C.; Van Calster, B.; Guerriero, S.; Savelli, L.; Leone, F.; Fischerova, D; Czekierdowski, A.; Fruscio, R.; Veldman, J.; Van de Putte, G.; Testa, A.C.; Bourne, T.; Valentin, L.; Timmerman, D.
2009-01-01
Aim: To evaluate the performance of subjective evaluation of ultrasound findings (pattern recognition) to discriminate endometriomas from other types of adnexal masses and to compare the demographic and ultrasound characteristics of the true positive cases with those cases that were presumed to be an endometrioma but proved to have a different histology (false positive cases) and the endometriomas missed by pattern recognition (false negative cases). Methods: All patients in the International Ovarian Tumor Analysis (IOTA ) studies were included for analysis. In the IOTA studies, patients with an adnexal mass that were preoperatively examined by expert sonologists following the same standardized ultrasound protocol were prospectively included in 21 international centres. Sensitivity and specificity to discriminate endometriomas from other types of adnexal masses using pattern recognition were calculated. Ultrasound and some demographic variables of the masses presumed to be an endometrioma were analysed (true positives and false positives) and compared with the variables of the endometriomas missed by pattern recognition (false negatives) as well as the true negatives. Results: IOTA phase 1, 1b and 2 included 3511 patients of which 2560 were benign (73%) and 951 malignant (27%). The dataset included 713 endometriomas. Sensitivity and specificity for pattern recognition were 81% (577/713) and 97% (2723/2798). The true positives were more often unilocular with ground glass echogenicity than the masses in any other category. Among the 75 false positive cases, 66 were benign but 9 were malignant (5 borderline tumours, 1 rare primary invasive tumour and 3 endometrioid adenocarcinomas). The presumed diagnosis suggested by the sonologist in case of a missed endometrioma was mostly functional cyst or cystadenoma. Conclusion: Expert sonologists can quite accurately discriminate endometriomas from other types of adnexal masses, but in this dataset 1% of the masses that were classified as endometrioma by pattern recognition proved to be malignancies. PMID:25478066
Mello, Juliana M R B; Bittelbrunn, Fernando P; Rockenbach, Marcio A B C; May, Guilherme G; Vedolin, Leonardo M; Kruger, Marilia S; Soldatelli, Matheus D; Zwetsch, Guilherme; de Miranda, Gabriel T F; Teixeira, Saone I P; Arruda, Bruna S
2017-12-01
To evaluate the quality assurance of mammography results at a reference institution for the diagnosis and treatment of breast cancer in southern Brazil, based on the BIRADS (Breast Imaging Reporting and Data System) 5th edition recommendations for auditing purposes. Retrospective cohort and cross-sectional study with 4502 patients (9668 mammographies)) who underwent at least one or both breast mammographies throughout 2013 at a regional public hospital, linked to a federal public university. The results were followed until 31 December 2014, including true positives (TPs), true negatives (TNs), false positives (FPs), false negatives (FNs), positive predictive values (PPVs), negative predictive value (NPV), sensitivity and specificity, with a confidence interval of 95%. The study showed high quality assurance, particularly regarding sensitivity (90.22%) and specificity (92.31%). The overall positive predictive value (PPV) was 65.35%, and the negative predictive value (NPV) was 98.32%. The abnormal interpretation rate (recall rate) was 12.26%. The results are appropriate when compared to the values proposed by the BIRADS 5th edition. Additionally, the study provided self-reflection considering our radiological practice, which is essential for improvements and collaboration regarding breast cancer detection. It may stimulate better radiological practice performance and continuing education, despite possible infrastructure and facility limitations. • Accurate quality performance rates are possible despite financial and governmental limitations. • Low-income institutions should develop standardised teamwork to improve radiological practice. • Regular mammography audits may help to increase the quality of public health systems.
Herbert, C; Kissler, J
2014-09-26
In sentences such as dogs cannot fly/bark, evaluation of the truth-value of the sentence is assumed to appear after the negation has been integrated into the sentence structure. Moreover negation processing and truth-value processing are considered effortful processes, whereas processing of the semantic relatedness of the words within sentences is thought to occur automatically. In the present study, modulation of event-related brain potentials (N400 and late positive potential, LPP) was investigated during an implicit task (silent listening) and active truth-value evaluation to test these theoretical assumptions and determine if truth-value evaluation will be modulated by the way participants processed the negated information implicitly prior to truth-value verification. Participants first listened to negated sentences and then evaluated these sentences for their truth-value in an active evaluation task. During passive listening, the LPP was generally more pronounced for targets in false negative (FN) than true negative (TN) sentences, indicating enhanced attention allocation to semantically-related but false targets. N400 modulation by truth-value (FN>TN) was observed in 11 out of 24 participants. However, during active evaluation, processing of semantically-unrelated but true targets (TN) elicited larger N400 and LPP amplitudes as well as a pronounced frontal negativity. This pattern was particularly prominent in those 11 individuals, whose N400 modulation during silent listening indicated that they were more sensitive to violations of the truth-value than to semantic priming effects. The results provide evidence for implicit truth-value processing during silent listening of negated sentences and for task dependence related to inter-individual differences in implicit negation processing. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.
Intra-operative Localization of Brachytherapy Implants Using Intensity-based Registration
KarimAghaloo, Z.; Abolmaesumi, P.; Ahmidi, N.; Chen, T.K.; Gobbi, D. G.; Fichtinger, G.
2010-01-01
In prostate brachytherapy, a transrectal ultrasound (TRUS) will show the prostate boundary but not all the implanted seeds, while fluoroscopy will show all the seeds clearly but not the boundary. We propose an intensity-based registration between TRUS images and the implant reconstructed from uoroscopy as a means of achieving accurate intra-operative dosimetry. The TRUS images are first filtered and compounded, and then registered to the uoroscopy model via mutual information. A training phantom was implanted with 48 seeds and imaged. Various ultrasound filtering techniques were analyzed, and the best results were achieved with the Bayesian combination of adaptive thresholding, phase congruency, and compensation for the non-uniform ultrasound beam profile in the elevation and lateral directions. The average registration error between corresponding seeds relative to the ground truth was 0.78 mm. The effect of false positives and false negatives in ultrasound were investigated by masking true seeds in the uoroscopy volume or adding false seeds. The registration error remained below 1.01 mm when the false positive rate was 31%, and 0.96 mm when the false negative rate was 31%. This fully automated method delivers excellent registration accuracy and robustness in phantom studies, and promises to demonstrate clinically adequate performance on human data as well. Keywords: Prostate brachytherapy, Ultrasound, Fluoroscopy, Registration. PMID:21152376
Evaluation of Second-Level Inference in fMRI Analysis
Roels, Sanne P.; Loeys, Tom; Moerkerke, Beatrijs
2016-01-01
We investigate the impact of decisions in the second-level (i.e., over subjects) inferential process in functional magnetic resonance imaging on (1) the balance between false positives and false negatives and on (2) the data-analytical stability, both proxies for the reproducibility of results. Second-level analysis based on a mass univariate approach typically consists of 3 phases. First, one proceeds via a general linear model for a test image that consists of pooled information from different subjects. We evaluate models that take into account first-level (within-subjects) variability and models that do not take into account this variability. Second, one proceeds via inference based on parametrical assumptions or via permutation-based inference. Third, we evaluate 3 commonly used procedures to address the multiple testing problem: familywise error rate correction, False Discovery Rate (FDR) correction, and a two-step procedure with minimal cluster size. Based on a simulation study and real data we find that the two-step procedure with minimal cluster size results in most stable results, followed by the familywise error rate correction. The FDR results in most variable results, for both permutation-based inference and parametrical inference. Modeling the subject-specific variability yields a better balance between false positives and false negatives when using parametric inference. PMID:26819578
Lantieri, Francesca; Malacarne, Michela; Gimelli, Stefania; Santamaria, Giuseppe; Coviello, Domenico; Ceccherini, Isabella
2017-01-01
The presence of false positive and false negative results in the Array Comparative Genomic Hybridization (aCGH) design is poorly addressed in literature reports. We took advantage of a custom aCGH recently carried out to analyze its design performance, the use of several Agilent aberrations detection algorithms, and the presence of false results. Our study provides a confirmation that the high density design does not generate more noise than standard designs and, might reach a good resolution. We noticed a not negligible presence of false negative and false positive results in the imbalances call performed by the Agilent software. The Aberration Detection Method 2 (ADM-2) algorithm with a threshold of 6 performed quite well, and the array design proved to be reliable, provided that some additional filters are applied, such as considering only intervals with average absolute log2ratio above 0.3. We also propose an additional filter that takes into account the proportion of probes with log2ratio exceeding suggestive values for gain or loss. In addition, the quality of samples was confirmed to be a crucial parameter. Finally, this work raises the importance of evaluating the samples profiles by eye and the necessity of validating the imbalances detected. PMID:28287439
[Evaluation of quality of HIV diagnostic procedures in Poland].
Parczewski, Miłosz; Madaliński, Kazimierz; Leszczyszyn-Pynka, Magdalena; Boroń-Kaczmarska, Anna
2010-01-01
The aim of this work was quality assessment of HIV diagnostic procedures in Poland, including human and technical resources as well as laboratory practice. Sixty questionnaires were distributed among diagnostic centers to obtain qualitative data. Basing on the survey data serological control using coded panels of HIV-1/2 samples was performed. Thirty-one filled questionnaires were received (50.8%). Surveyed laboratories perform from 350 to 5500 serological screening tests per year. In most of laboratories fourth generation assays are available, while Blood Donation Centers screen the blood both with serological assays and by HIV-RNA detection. Sanitary and Epidemiological Stations and academic laboratories hold the ISO/IEC 17025 or IS0 9001:2001 accreditation, five of the surveyed centers participate in Labquality assurance and two in Quality Control in Molecular Diagnostics programs. Data of control serological testing were received from 21 centers. In the quality control assessment 194 analyses were performed with 91 true negative, 2 false negative, 96 true positive and 5 false positive results. False negative rate of % and false positive rate of 5.2% was noted for this study. Currently, virtually no guidelines related to the HIV-diagnostics quality assurance and control in Poland are in delineated. Development of the national unified quality control system, basing on the central institution is highly desirable. National certification within the frames of the quality control and assurance program should be mandatory for all the diagnostic labs, and aim at improvement of reliability of the result distributed among clinicians and patients.
A New Method for Assessing How Sensitivity and Specificity of Linkage Studies Affects Estimation
Moore, Cecilia L.; Amin, Janaki; Gidding, Heather F.; Law, Matthew G.
2014-01-01
Background While the importance of record linkage is widely recognised, few studies have attempted to quantify how linkage errors may have impacted on their own findings and outcomes. Even where authors of linkage studies have attempted to estimate sensitivity and specificity based on subjects with known status, the effects of false negatives and positives on event rates and estimates of effect are not often described. Methods We present quantification of the effect of sensitivity and specificity of the linkage process on event rates and incidence, as well as the resultant effect on relative risks. Formulae to estimate the true number of events and estimated relative risk adjusted for given linkage sensitivity and specificity are then derived and applied to data from a prisoner mortality study. The implications of false positive and false negative matches are also discussed. Discussion Comparisons of the effect of sensitivity and specificity on incidence and relative risks indicate that it is more important for linkages to be highly specific than sensitive, particularly if true incidence rates are low. We would recommend that, where possible, some quantitative estimates of the sensitivity and specificity of the linkage process be performed, allowing the effect of these quantities on observed results to be assessed. PMID:25068293
Bortcosh, William; Siedner, Mark; Carroll, Ryan W.
2018-01-01
OBJECTIVE Diagnosis of bacterial meningitis often requires cytometry, chemistry and/or microbiologic culture capabilities. Unfortunately, laboratory resources in low-resource settings (LRS) often lack the capacity to perform these studies. We sought to determine whether the presence of white blood cells in CSF detected by commercially available urine reagent strips could aid in the diagnosis of bacterial meningitis. METHODS We searched PubMed for studies published between 1980 and 2016 that investigated the use of urine reagent strips to identify cerebrospinal fluid (CSF) pleocytosis. We assessed studies in any language that enrolled subjects who underwent lumbar puncture and had cerebrospinal fluid testing by both standard laboratory assays and urine reagent strips. We abstracted true-positive, false-negative, false-positive and true-negative counts for each study using a diagnostic threshold of ≥10 white blood cells per microlitre for suspected bacterial meningitis and performed mixed regression modelling with random effects to estimate pooled diagnostic accuracy across studies. RESULTS Our search returned 13 studies including 2235 participants. Urine reagent strips detected CSF pleocytosis with a pooled sensitivity of 92% (95% CI: 84–96), a pooled specificity of 98% (95% CI: 94–99) and a negative predictive value of 99% when the bacterial meningitis prevalence is 10%. CONCLUSIONS Urine reagent strips could provide a rapid and accurate tool to detect CSF pleocytosis, which, if negative, can be used to exclude diagnosis of bacterial meningitis in settings without laboratory infrastructure. Further investigation of the diagnostic value of using protein, glucose and bacteria components of these strips is warranted. PMID:28627004
ERIC Educational Resources Information Center
Severo, Milton; Silva-Pereira, Fernanda; Ferreira, Maria Amelia
2013-01-01
Several studies have shown that the standard error of measurement (SEM) can be used as an additional “safety net” to reduce the frequency of false-positive or false-negative student grading classifications. Practical examinations in clinical anatomy are often used as diagnostic tests to admit students to course final examinations. The aim of this…
The Precautionary Principle and Electric and Magnetic Fields
Jamieson, Dale; Wartenberg, Daniel
2001-01-01
Current environmental regulation represents a paternalistic policy, more concerned to avoid false positives than false negatives, limiting opportunities for individuals to make choices between risk-avoidance and risk-taking alternatives. For example, many exposures to magnetic fields could be reduced at little or no cost but are not considered seriously, owing to the uncertainty of risk and the concern to avoid false positives. Even though precautionary approaches that focus on avoiding false negatives often do not lead to adverse economic consequences or irrational choices, such approaches usually are not taken. The value of autonomy and the proper role of governmental paternalism with respect to environmental policy need to be considered more carefully in environmental decision making. PMID:11527754
Andreis, D; Bonardi, S; Allevi, G; Aguggini, S; Gussago, F; Milani, M; Strina, C; Spada, D; Ferrero, G; Ungari, M; Rocca, A; Nanni, O; Roviello, G; Berruti, A; Harris, A L; Fox, S B; Roviello, F; Polom, K; Bottini, A; Generali, D
2016-10-01
Histological status of axillary lymph nodes is an important prognostic factor in patients receiving surgery for breast cancer (BC). Sentinel lymph node (SLN) biopsy (B) has rapidly replaced axillary lymph node dissection (ALND), and is now the standard of care for axillary staging in patients with clinically node-negative (N0) operable BC. The aim of this study is to compare pretreatment lymphoscintigraphy with a post primary systemic treatment (PST) scan in order to reduce the false-negative rates for SLNB. In this single-institution study we considered 170 consecutive T2-4 N0-1 M0 BC patients treated with anthracycline-based PST. At the time of incisional biopsy, we performed sentinel lymphatic mapping. After PST, all patients repeated lymphoscintigraphy with the same methodology. During definitive surgery we performed further sentinel lymphatic mapping, SLNB and ALND. The SLN was removed in 158/170 patients giving an identification rate of 92.9% (95% confidence interval (CI) = 88.0-96.3%) and a false-negative rate of 14.0% (95% CI = 6.3-25.8%). SLNB revealed a sensitivity of 86.0% (95% CI = 74.2-93.7%), an accuracy of 94.9% (95% CI = 90.3-97.8%) and a negative predictive value of 92.7% (95% CI = 86.1-96.8%). Identification rate, sensitivity and accuracy are in accordance with other studies on SLNB after PST, even after clinically negative node conversion following PST. This study confirms that diagnostic biopsy and neoadjuvant chemotherapy maintain breast lymphatic drainage unaltered. Copyright © 2016 Elsevier Ltd. All rights reserved.
Dassanayake, Dinesh L B; Wimalaratna, Harith; Agampodi, Suneth B; Liyanapathirana, Veranja C; Piyarathna, Thibbotumunuwe A C L; Goonapienuwala, Bimba L
2009-04-22
Leptospirosis is endemic in both urban and rural areas of Sri Lanka and there had been many out breaks in the recent past. This study was aimed at validating the leptospirosis surveillance case definition, using the Microscopic Agglutination Test (MAT). The study population consisted of patients with undiagnosed acute febrile illness who were admitted to the medical wards of the Teaching Hospital Kandy, from 1st July 2007 to 31st July 2008. The subjects were screened to diagnose leptospirosis according to the leptospirosis case definition. MAT was performed on blood samples taken from each patient on the 7th day of fever. Leptospirosis case definition was evaluated in regard to sensitivity, specificity and predictive values, using a MAT titre >or= 1:800 for confirming leptospirosis. A total of 123 patients were initially recruited of which 73 had clinical features compatible with the surveillance case definition. Out of the 73 only 57 had a positive MAT result (true positives) leaving 16 as false positives. Out of the 50 who didn't have clinical features compatible with the case definition 45 had a negative MAT as well (true negatives), therefore 5 were false negatives. Total number of MAT positives was 62 out of 123. According to these results the test sensitivity was 91.94%, specificity 73.77%, positive predictive value and negative predictive values were 78.08% and 90% respectively. Diagnostic accuracy of the test was 82.93%. This study confirms that the surveillance case definition has a very high sensitivity and negative predictive value with an average specificity in diagnosing leptospirosis, based on a MAT titre of >or= 1: 800.
Nandipati, Kalyana C; Allamaneni, Shyam; Kakarla, Ravindra; Wong, Alfredo; Richards, Neil; Satterfield, James; Turner, James W; Sung, Kae-Jae
2011-05-01
Early identification of pneumothorax is crucial to reduce the mortality in critically injured patients. The objective of our study is to investigate the utility of surgeon performed extended focused assessment with sonography for trauma (EFAST) in the diagnosis of pneumothorax. We prospectively analysed 204 trauma patients in our level I trauma center over a period of 12 (06/2007-05/2008) months in whom EFAST was performed. The patients' demographics, type of injury, clinical examination findings (decreased air entry), CXR, EFAST and CT scan findings were entered into the data base. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated. Of 204 patients (mean age--43.01+/-19.5 years, sex--male 152, female 52) 21 (10.3%) patients had pneumothorax. Of 21 patients who had pneumothorax 12 were due to blunt trauma and 9 were due to penetrating trauma. The diagnosis of pneumothorax in 204 patients demonstrated the following: clinical examination was positive in 17 patients (true positive in 13/21, 62%; 4 were false positive and 8 were false negative), CXR was positive in 16 (true positive in 15/19, 79%; 1 false positive, 4 missed and 2 CXR not performed before chest tube) patients and EFAST was positive in 21 patients (20 were true positive [95.2%], 1 false positive and 1 false negative). In diagnosing pneumothorax EFAST has significantly higher sensitivity compared to the CXR (P=0.02). Surgeon performed trauma room extended FAST is simple and has higher sensitivity compared to the chest X-ray and clinical examination in detecting pneumothorax. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harwood, S.J.; Anderson, M.W.; Klein, R.C.
1984-01-01
Emission computed tomography (ECT) studies were performed on a GE 400 A/T camera and ADAC computers (system 3 and system 3300). Thirty-three sets of ECT and planar images were obtained in 20 patients over a six month period. Imaging was performed 48 hours after the intravenous administration of 5 mc of Gallium 67 citrate. No bowel preparation was employed. Comparison is made of the initial nuclear medicine report derived from planar and ECT imaging aided by clinical knowledge versus the consensus opinion of two nuclear medicine physicians reading the planar images along with minimal clinical information. The lymphoma series consistsmore » of 18 scans in 10 patients. There were 5 scans in which a false negative planar interpretation was changed to a true positive ECT interpretation. Sensitivity of planar imaging for lymphoma was 58% which rose to 100% with addition of ECT information. There were no false positives by either technique. There were 5 sets of scans in 5 lung carcinoma patients. Sensitivity of the planar images was 60% because of 2 false negative results. Sensitivity of the ECT technique was 100%. There were no false positives. The infection series consists of 10 scans in 5 patients. Sensitivity of ECT was 100%, sensitivity of planar was 66%. There was 1 false positive planar. For the total series the accuracy of planar imaging was 69% and the predictive value of a negative planar interpretation was 44%. Corresponding values for ECT imaging were 100%. The authors' experience demonstrates significant increase in sensitivity without loss of specificity resulting from the use of Emission Computed Tomography in both chest and abdomen in patients with lymphoma, infection, and lung cancer.« less
Imberger, Georgina; Thorlund, Kristian; Gluud, Christian; Wetterslev, Jørn
2016-08-12
Many published meta-analyses are underpowered. We explored the role of trial sequential analysis (TSA) in assessing the reliability of conclusions in underpowered meta-analyses. We screened The Cochrane Database of Systematic Reviews and selected 100 meta-analyses with a binary outcome, a negative result and sufficient power. We defined a negative result as one where the 95% CI for the effect included 1.00, a positive result as one where the 95% CI did not include 1.00, and sufficient power as the required information size for 80% power, 5% type 1 error, relative risk reduction of 10% or number needed to treat of 100, and control event proportion and heterogeneity taken from the included studies. We re-conducted the meta-analyses, using conventional cumulative techniques, to measure how many false positives would have occurred if these meta-analyses had been updated after each new trial. For each false positive, we performed TSA, using three different approaches. We screened 4736 systematic reviews to find 100 meta-analyses that fulfilled our inclusion criteria. Using conventional cumulative meta-analysis, false positives were present in seven of the meta-analyses (7%, 95% CI 3% to 14%), occurring more than once in three. The total number of false positives was 14 and TSA prevented 13 of these (93%, 95% CI 68% to 98%). In a post hoc analysis, we found that Cochrane meta-analyses that are negative are 1.67 times more likely to be updated (95% CI 0.92 to 2.68) than those that are positive. We found false positives in 7% (95% CI 3% to 14%) of the included meta-analyses. Owing to limitations of external validity and to the decreased likelihood of updating positive meta-analyses, the true proportion of false positives in meta-analysis is probably higher. TSA prevented 93% of the false positives (95% CI 68% to 98%). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Are overreferrals on developmental screening tests really a problem?
Glascoe, F P
2001-01-01
Developmental screening tests, even those meeting standards for screening test accuracy, produce numerous false-positive results for 15% to 30% of children. This is thought to produce unnecessary referrals for diagnostic testing or special services and increase the cost of screening programs. To explore whether children who pass screening tests differ in important ways from those who do not and to determine whether children overreferred for testing benefit from the scrutiny of diagnostic testing and treatment planning. Subjects were a national sample of 512 parents and their children (age range of the children, 7 months to 8 years) who participated in validation studies of various screening tests. Psychological examiners adhering to standardized directions obtained informed consent and administered at least 2 developmental screening measures (the Brigance Screens, the Battelle Developmental Inventory Screening Test, the Denver-II, and the Parents' Evaluations of Developmental Status) and a concurrent battery of diagnostic measures, including tests of intelligence, language, and academic achievement (for children aged 2(1/2) years and older). The performance on diagnostic measures of children who failed screening but were not found to have a disability (false positives) was compared with that of children who passed screening and did not have a disability on diagnostic testing (true negatives). Children with false-positive scores performed significantly (P<.001) lower on diagnostic measures than did children with true-negative scores. The false-positive group had scores in adaptive behavior, language, intelligence, and academic achievement that were 9 to 14 points lower than the scores of those in the true-negative group. When viewing the likelihood of scoring below the 25th percentile on diagnostic measures, children with false-positive scores had a relative risk of 2.6 in adaptive behavior (95% confidence interval [CI], 1.67-4.21), 3.1 in language skills (95% CI, 1.90-5.20), 6.7 on intelligence tests (95% CI, 3.28-13.50), and 4.9 on academic measures (95% CI, 2.61-9.28). Overall, 151 (70%) of the children with false-positive results scored below the 25th percentile on 1 or more diagnostic measures (the point at which most children have difficulty benefiting from typical classroom instruction) in contrast with 64 (29%) of the children with true-negative scores (odds ratio, 5.6; 95% CI, 3.73-8.49). Children with false-positive scores were also more likely to be nonwhite and to have parents who had not graduated from high school. Performance differences between children with true-negative scores and children with false-positive scores continued to be significant (P<.001) even after adjusting for sociodemographic differences between groups. Children overreferred for diagnostic testing by developmental screens perform substantially lower than children with true-negative scores on measures of intelligence, language, and academic achievement-the 3 best predictors of school success. These children also carry more psychosocial risk factors, such as limited parental education and minority status. Thus, children with false-positive screening results are an at-risk group for whom diagnostic testing may not be an unnecessary expense but rather a beneficial and needed service that can help focus intervention efforts. Although such testing will not indicate a need for special education placement, it can be useful in identifying children's needs for other programs known to improve language, cognitive, and academic skills, such as Head Start, Title I services, tutoring, private speech-language therapy, and quality day care.
19 CFR 207.14 - Negative petition determination.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 3 2010-04-01 2010-04-01 false Negative petition determination. 207.14 Section... SUBSIDIZED EXPORTS TO THE UNITED STATES Preliminary Determinations § 207.14 Negative petition determination... section 732(d) of the Act that the administering authority has made a negative petition determination...
Potential for false positive HIV test results with the serial rapid HIV testing algorithm.
Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K
2012-03-19
Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.
Potential for false positive HIV test results with the serial rapid HIV testing algorithm
2012-01-01
Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals. PMID:22429706
Beyer, Lukas Philipp; Wassermann, Florian; Pregler, Benedikt; Michalik, Katharina; Rennert, Janine; Wiesinger, Isabel; Stroszczynski, Christian; Wiggermann, Philipp; Jung, Ernst Michael
2017-12-01
The purpose of this study was to compare contrast-enhanced ultrasound (CEUS), magnetic resonance imaging (MRI) using liver-specific contrast agent and a combination of both for the characterization of focal liver lesions (FLL). 83 patients with both benign and malignant liver lesions were examined using CEUS and MRI after the intravenous administration of liver-specific contrast media. All patients had inconclusive results from prior imaging examinations. Histopathological specimens could be obtained in 53 patients. Ultrasound was performed using a multi-frequency curved probe (1 - 6 MHz) after the injection of 1 - 2.4 ml ultrasound contrast media. The sensitivity, specificity, positive predictive value and negative predictive value of CEUS, MRI and a combination of both (CEUS + MRI) were compared. The sensitivity, specificity, positive and negative predictive values regarding lesion classification were 90.9 %, 70.6 %, 92.3 % and 66.6 %, respectively, for CEUS; 90.9 %, 82.4 %, 95.2 % and 70.0 %, respectively, for MRI; and 96.9 %, 70.6 %, 92.7 % and 85.7 % respectively, for CEUS + MRI. There were no statistically significant differences. 6 malignant lesions were missed using CEUS or MRI alone (false negatives). The use of both modalities combined reduced the false-negative results to 2. CEUS and MRI with liver-specific contrast media are very reliable and of equal informative value in the characterization of focal liver lesions. The number of false-negative results can be decreased using a combination of the two methods. © Georg Thieme Verlag KG Stuttgart · New York.
Screening for acute HIV infection in South Africa: finding acute and chronic disease
Bassett, Ingrid V.; Chetty, Senica; Giddy, Janet; Reddy, Shabashini; Bishop, Karen; Lu, Zhigang; Losina, Elena; Freedberg, Kenneth A.; Walensky, Rochelle P.
2010-01-01
Background The yield of screening for acute HIV infection among general medical patients in resource-scarce settings remains unclear. Our objective was to evaluate a strategy of pooled HIV plasma RNA to diagnose acute HIV infection in patients with negative or discordant rapid HIV antibody tests in Durban, South Africa. Methods We prospectively enrolled patients with negative or discordant rapid HIV antibody tests from a routine HIV screening program in an outpatient department in Durban with an HIV prevalence of 48%. Study participants underwent venipuncture for pooled qualitative HIV RNA, and if positive, quantitative RNA, enzyme immunoassay and Western Blot (WB). Patients with negative or indeterminate WB and positive quantitative HIV RNA were considered acutely infected. Those with chronic infection (positive RNA and WB) despite negative or discordant rapid HIV tests were considered false negative rapid antibody tests. Results Nine hundred ninety-four participants were enrolled with either negative (N=976) or discordant (N=18) rapid test results. Eleven (1.1%, 95% CI: 0.6–2.0%) had acute HIV infection. Of the 994 patients, an additional 20 (2.0%, 95% CI: 1.3–.3.1%) had chronic HIV infection (false negative rapid test). Conclusions One percent of outpatients with negative or discordant rapid HIV tests in Durban, South Africa had acute HIV infection readily detectable through pooled serum HIV RNA screening. Pooled RNA testing also identified an additional 2% of patients with chronic HIV infection. HIV RNA screening has the potential to identify both acute and chronic HIV infections that are otherwise missed by standard HIV testing algorithms. PMID:20553336
Navabi, Nazlee; Montebatsi, Milton; Scott, Michelle; Gluckman, Stephen J; Reid, Michael J A
2015-01-01
A case of false-negative serum latex agglutination cryptococcal antigen (CRAG) test in a 45-year-old HIV-positive male with Cryptococcus-positive culture is described. The patient was presented to a hospital in Botswana, with breathlessness and a diffuse papular rash. His CD4 count was 25 cells/μL. Despite the suspicion for disseminated cryptococcal disease, an initial serum CRAG latex test was negative. Results of subsequent Indian ink staining, culture of cerebrospinal fluid and skin scrapings, and serum lateral flow immunoassay (LFA) were all positive for Cryptococcus neoformans. There are several possible explanations for the false-negative CRAG latex test. Given the positive LFA result, we speculate that disease may have been caused by Cryptococcus gattii, which is estimated to be responsible for between 15% and 30% of all cryptococcal diseases in Botswana. Reduced sensitivity of CRAG latex assays for detecting C gattii may lead to underdiagnosis of cryptococcal infection. © The Author(s) 2014.
Theron, Grant; Venter, Rouxjeane; Smith, Liezel; Esmail, Aliasgar; Randall, Philippa; Sood, Vishesh; Oelfese, Suzette; Calligaro, Greg; Warren, Robin; Dheda, Keertan
2018-03-01
Globally, Xpert MTB/RIF (Xpert) is the most widely used PCR test for the diagnosis of tuberculosis (TB). Positive results in previously treated patients, which are due to old DNA or active disease, are a diagnostic dilemma. We prospectively retested sputum from 238 patients, irrespective of current symptoms, who were previously diagnosed to be Xpert positive and treated successfully. Patients who retested as Xpert positive and culture negative were exhaustively investigated (repeat culture, chest radiography, bronchoscopy with bronchoalveolar lavage, long-term clinical follow-up). We evaluated whether the duration since previous treatment completion, mycobacterial burden (the Xpert cycle threshold [ C T ] value), and reclassification of Xpert-positive results with a very low semiquantitation level to Xpert-negative results reduced the rate of false positivity. A total of 229/238 (96%) of patients were culture negative. Sixteen of 229 (7%) were Xpert positive a median of 11 months (interquartile range, 5 to 19 months) after treatment completion. The specificity was 93% (95% confidence interval [CI], 89 to 96%). Nine of 15 (40%) Xpert-positive, culture-negative patients reverted to Xpert negative after 2 to 3 months (1 patient declined further participation). Patients with false-positive Xpert results had a lower mycobacterial burden than patients with true-positive Xpert results ( C T , 28.7 [95% CI, 27.2 to 30.4] versus 17.6 [95% CI, 16.9 to 18.2]; P < 0.001), an increased likelihood of a chest radiograph not compatible with active TB (5/15 patients versus 0/5 patients; P = 0.026), and less-viscous sputum (15/16 patients versus 2/5 patients whose sputum was graded as mucoid or less; P = 0.038). All patients who initially retested as Xpert positive and culture negative ("Xpert false positive") were clinically well without treatment after follow-up. The duration since the previous treatment poorly predicted false-positive results (a duration of ≤2 years identified only 66% of patients with false-positive results). Reclassifying Xpert-positive results with a very low semiquantitation level to Xpert negative improved the specificity (+3% [95% CI, +2 to +5%]) but reduced the sensitivity (-10% [95% CI, -4 to -15%]). Patients with previous TB retested with Xpert can have false-positive results and thus not require treatment. These data inform clinical practice by highlighting the challenges in interpreting Xpert-positive results, underscore the need for culture, and have implications for next-generation ultrasensitive tests. Copyright © 2018 American Society for Microbiology.
Kim, Mi Young; Choi, Nami; Yang, Jung-Hyun; Yoo, Young Bum; Park, Kyoung Sik
2015-10-01
Shear-wave elastography (SWE) has the potential to improve diagnostic performance of conventional ultrasound (US) in differentiating benign from malignant breast masses. To investigate false positive or negative results of SWE in differentiating benign from malignant breast masses and to analyze clinical and imaging characteristics of the masses with false SWE findings. From May to October 2013, 166 breast lesions of 164 consecutive women (mean age, 45.3 ± 10.1 years) who had been scheduled for biopsy were included. Conventional US and SWE were performed in all women before biopsy. Clinical, ultrasonographic morphologic features and SWE parameters (pattern classification and standard deviation [SD]) were recorded and compared with the histopathology results. Patient and lesion factors in the "true" and "false" groups were compared. Of the 166 masses, 118 (71.1%) were benign and 48 (28.9%) were malignant. False SWE features were more frequently observed in benign masses. False positive rates of benign masses and false negative rates of malignancy were 53% and 8.2%, respectively, using SWE pattern analysis and were 22.4% and 10.3%, respectively, using SD values. A lesion boundary of the masses on US (P = 0.039) and younger patient age (P = 0.047) were significantly associated with false SWE findings. These clinical and ultrasonographic features need to be carefully evaluated in performance and interpretation of SWE examinations. © The Foundation Acta Radiologica 2014.
Jacobson, Linda S; McIntyre, Lauren; Mykusz, Jenny
2018-02-01
Objectives Real-time PCR provides quantitative information, recorded as the cycle threshold (Ct) value, about the number of organisms detected in a diagnostic sample. The Ct value correlates with the number of copies of the target organism in an inversely proportional and exponential relationship. The aim of the study was to determine whether Ct values could be used to distinguish between culture-positive and culture-negative samples. Methods This was a retrospective analysis of Ct values from dermatophyte PCR results in cats with suspicious skin lesions or suspected exposure to dermatophytosis. Results One hundred and thirty-two samples were included. Using culture as the gold standard, 28 were true positives, 12 were false positives and 92 were true negatives. The area under the curve for the pretreatment time point was 96.8% (95% confidence interval [CI] 94.2-99.5) compared with 74.3% (95% CI 52.6-96.0) for pooled data during treatment. Before treatment, a Ct cut-off of <35.7 (approximate DNA count 300) provided a sensitivity of 92.3% and specificity of 95.2%. There was no reliable cut-off Ct value between culture-positive and culture-negative samples during treatment. Ct values prior to treatment differed significantly between the true-positive and false-positive groups ( P = 0.0056). There was a significant difference between the pretreatment and first and second negative culture time points ( P = 0.0002 and P <0.0001, respectively). However, there was substantial overlap between Ct values for true positives and true negatives, and for pre- and intra-treatment time points. Conclusions and relevance Ct values had limited usefulness for distinguishing between culture-positive and culture-negative cases when field study samples were analyzed. In addition, Ct values were less reliable than fungal culture for determining mycological cure.
Emotion and false memory: The context-content paradox.
Bookbinder, S H; Brainerd, C J
2016-12-01
False memories are influenced by a variety of factors, but emotion is a variable of special significance, for theoretical and practical reasons. Interestingly, emotion's effects on false memory depend on whether it is embedded in the content of to-be-remembered events or in our moods, where mood is an aspect of the context in which events are encoded. We sketch the theoretical basis for this content-context dissociation and then review accumulated evidence that content and context effects are indeed different. Paradoxically, we find that in experiments on spontaneous and implanted false memories, negatively valenced content foments distortion, but negatively valenced moods protect against it. In addition, correlational data show that enduring negative natural moods (e.g., depression) foment false memory. Current opponent-process models of false memory, such as fuzzy-trace theory, are able to explain the content-context dissociation: Variations in emotional content primarily affect memory for the gist of events, whereas variations in emotional context primarily affect memory for events' exact verbatim form. Important questions remain about how these effects are modulated by variations in memory tests and in arousal. Promising methods of tackling those questions are outlined, especially designs that separate the gist and verbatim influences of emotion. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Tafra, Lorraine; Lannin, Donald R.; Swanson, Melvin S.; Van Eyk, Jason J.; Verbanac, Kathryn M.; Chua, Arlene N.; Ng, Peter C.; Edwards, Maxine S.; Halliday, Bradford E.; Henry, C. Alan; Sommers, Linda M.; Carman, Claire M.; Molin, Melinda R.; Yurko, John E.; Perry, Roger R.; Williams, Robert
2001-01-01
Objective To determine the factors associated with false-negative results on sentinel node biopsy and sentinel node localization (identification rate) in patients with breast cancer enrolled in a multicenter trial using a combination technique of isosulfan blue with technetium sulfur colloid (Tc99). Summary Background Data Sentinel node biopsy is a diagnostic test used to detect breast cancer metastases. To test the reliability of this method, a complete lymph node dissection must be performed to determine the false-negative rate. Single-institution series have reported excellent results, although one multicenter trial reported a false-negative rate as high as 29% using radioisotope alone. A multicenter trial was initiated to test combined use of Tc99 and isosulfan blue. Methods Investigators (both private-practice and academic surgeons) were recruited after attending a course on the technique of sentinel node biopsy. No investigator participated in a learning trial before entering patients. Tc99 and isosulfan blue were injected into the peritumoral region. Results Five hundred twenty-nine patients underwent 535 sentinel node biopsy procedures for an overall identification rate in finding a sentinel node of 87% and a false-negative rate of 13%. The identification rate increased and the false-negative rate decreased to 90% and 4.3%, respectively, after investigators had performed more than 30 cases. Univariate analysis of tumor showed the poorest success rate with older patients and inexperienced surgeons. Multivariate analysis identified both age and experience as independent predictors of failure. However, with older patients, inexperienced surgeons, and patients with five or more metastatic axillary nodes, the false-negative rate was consistently greater. Conclusions This multicenter trial, from both private practice and academic institutions, is an excellent indicator of the general utility of sentinel node biopsy. It establishes the factors that play an important role (patient age, surgical experience, tumor location) and those that are irrelevant (prior surgery, tumor size, Tc99 timing). This widens the applicability of the technique and identifies factors that require further investigation. PMID:11141225
Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck
2015-05-14
Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false negative results due to seroconversion or misclassification by the lower sensitivity dilution test. Further research is needed to determine if these results can be replicated in other settings. ClinicalTrials.gov, NCT01716299 .
Sensitivity and Specificity of Histoplasma Antigen Detection by Enzyme Immunoassay.
Cunningham, Lauren; Cook, Audrey; Hanzlicek, Andrew; Harkin, Kenneth; Wheat, Joseph; Goad, Carla; Kirsch, Emily
2015-01-01
The objective of this study was to evaluate the sensitivity and specificity of an antigen enzyme immunoassay (EIA) on urine samples for the diagnosis of histoplasmosis in dogs. This retrospective medical records review included canine cases with urine samples submitted for Histoplasma EIA antigen assay between 2007 and 2011 from three veterinary institutions. Cases for which urine samples were submitted for Histoplasma antigen testing were reviewed and compared to the gold standard of finding Histoplasma organisms or an alternative diagnosis on cytology or histopathology. Sensitivity, specificity, negative predictive value, positive predictive value, and the kappa coefficient and associated confidence interval were calculated for the EIA-based Histoplasma antigen assay. Sixty cases met the inclusion criteria. Seventeen cases were considered true positives based on identification of the organism, and 41 cases were considered true negatives with an alternative definitive diagnosis. Two cases were considered false negatives, and there were no false positives. Sensitivity was 89.47% and the negative predictive value was 95.35%. Specificity and the positive predictive value were both 100%. The kappa coefficient was 0.9207 (95% confidence interval, 0.8131-1). The Histoplasma antigen EIA test demonstrated high specificity and sensitivity for the diagnosis of histoplasmosis in dogs.
Clasen, Frederick Johannes; Pierneef, Rian Ewald; Slippers, Bernard; Reva, Oleg
2018-05-03
Genomic islands (GIs) are inserts of foreign DNA that have potentially arisen through horizontal gene transfer (HGT). There are evidences that GIs can contribute significantly to the evolution of prokaryotes. The acquisition of GIs through HGT in eukaryotes has, however, been largely unexplored. In this study, the previously developed GI prediction tool, SeqWord Gene Island Sniffer (SWGIS), is modified to predict GIs in eukaryotic chromosomes. Artificial simulations are used to estimate ratios of predicting false positive and false negative GIs by inserting GIs into different test chromosomes and performing the SWGIS v2.0 algorithm. Using SWGIS v2.0, GIs are then identified in 36 fungal, 22 protozoan and 8 invertebrate genomes. SWGIS v2.0 predicts GIs in large eukaryotic chromosomes based on the atypical nucleotide composition of these regions. Averages for predicting false negative and false positive GIs were 20.1% and 11.01% respectively. A total of 10,550 GIs were identified in 66 eukaryotic species with 5299 of these GIs coding for at least one functional protein. The EuGI web-resource, freely accessible at http://eugi.bi.up.ac.za , was developed that allows browsing the database created from identified GIs and genes within GIs through an interactive and visual interface. SWGIS v2.0 along with the EuGI database, which houses GIs identified in 66 different eukaryotic species, and the EuGI web-resource, provide the first comprehensive resource for studying HGT in eukaryotes.
Sharma, S. T.; Raff, H.
2011-01-01
Context: Anomalous venous drainage can lead to false-negative inferior petrosal sinus sampling (IPSS) results. Baseline inferior petrosal sinus to peripheral (IPS/P) prolactin ratio higher than 1.8 ipsilateral to the highest ACTH ratio has been proposed to verify successful catheterization. Prolactin-normalized ACTH IPS/P ratios may differentiate Cushing's disease (CD) from ectopic ACTH syndrome (EAS). Objective: Our objective was to examine the utility of prolactin measurement during IPSS. Design, Setting, and Participants: We conducted a retrospective analysis of prolactin levels in basal and CRH-stimulated IPSS samples in ACTH-dependent Cushing's syndrome (2007–2010). Results: Twenty-five of 29 patients had a pathologically proven diagnosis (17 CD and eight EAS). IPSS results were partitioned into true positive for CD (n = 16), true negative (n = 7), false negative (n = 1), and false positive (n = 1). Prolactin IPS/P ratio suggested successful IPSS in eight of 11 with abnormal venograms. Baseline prolactin IPS/P ratio was helpful in two patients with abnormal venograms and false-negative (catheterization unsuccessful) or true-negative (catheterization successful) IPSS results; the normalized ratio correctly diagnosed their disease. Normalized ACTH IPS/P ratio was at least 1.3 in all with CD, but prolactin IPS/P ratios were misleadingly low in two. One patient with cyclic EAS had a false-positive IPSS when eucortisolemic (baseline prolactin IPS/P = 1.7; normalized ratio = 5.6). All other EAS patients had normalized ratios no higher than 0.7. Conclusion: Prolactin measurement and evaluation of the venogram can improve diagnostic accuracy when IPSS results suggest EAS but is not necessary with positive IPSS results. Confirmation of hypercortisolemia remains a prerequisite for IPSS. A normalized ratio of 0.7–1.3 was not diagnostic. PMID:22031511
HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites
Kosack, Cara S.; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng’ang’a, Anne; Andre, Bita; Zahinda, Jean-Paul BN; Fransen, Katrien; Page, Anne-Laure
2017-01-01
Abstract Introduction: We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. Methods: In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Results: Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. Conclusions: The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy. PMID:28691437
HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites.
Kosack, Cara S; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng'ang'a, Anne; Andre, Bita; Zahinda, Jean-Paul Bn; Fransen, Katrien; Page, Anne-Laure
2017-07-03
We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy.
Kapan, Murat; Onder, Akin; Girgin, Sadullah; Ulger, Burak Veli; Firat, Ugur; Uslukaya, Omer; Oguz, Abdullah
2015-02-01
The aim of this study was to analyze the presence of malignancy in patients with Hashimoto's thyroiditis and to investigate the reliability of preoperative fine-needle aspiration biopsy (FNAB). The retrospective study included 44 patients who were operated on for nodular goiter between December 2010 and October 2011. The patients underwent thyroidectomy following a cytologic analysis plus FNAB. Hashimoto's thyroiditis was confirmed on histopathology in all patients. FNAB results were defined as benign in 14 (31.8%), suspicion for malignancy in 17 (38.6%), malignant in 9 (20.5%), and inadequate in 4 (9.1%). Following the thyroidectomy, presence of papillary thyroid carcinoma and follicular variant of papillary thyroid carcinoma were detected in 10 patients (22.7%) and 1 (2.3%) patient, respectively. The FNAB results were interpreted in terms of malignancy, which revealed the sensitivity as 80%; specificity, 40%; false positives, 69.2%; false negatives, 14.3%; positive predictive value, 31.8%; negative predictive value, 85.7%; and diagnostic accuracy, 50%. The coexistence of Hashimoto's thyroiditis with papillary thyroid carcinoma is quite common. The FNAB results for such cases are hard to evaluate, and they are likely to increase the number of false positives.
Microscopic diagnosis of dysbacteriosis in stained vaginal smears in clinical practice.
Verbruggen, Banut-Sabine M; Boon, Mathilde E; Melkerl, Peter; van Haaften, Maarten; Heintz, A Peter M
2006-10-01
Dysbacteriosis is a microscopical diagnosis. In women with dysbacteriosis, an overgrowth of coccoid bacteria and almost a complete absence of lactobacilli are observed in the (stained) vaginal smear. The aim of this study was to determine the accuracy of this microscopic diagnosis in clinical practice. The analysis concerned 342 consecutive cases in which the microscopy of the stained smears was performed by general practitioners trained in diagnosing dysbacteriosis. These smears were sent to the pathologist for confirmation of the microscopical diagnosis of the clinician. The cytological diagnoses of the pathologist, sometimes performed on restained slides when the quality of the staining was substandard, were considered as the "gold standard." In 92 of the 342 cases, dysbacteriosis was unequivocally established by the pathologist. Sensitivity and specificity of the microscopical diagnoses of the clinicians were 40% and 85%, respectively. There were 37 false-positive and 54 false-negative diagnoses of dysbacteriosis rendered by the clinicians. The most frequent reason for a false-negative diagnosis was an excess of lactobacilli in the smear. This study shows that even in stained smears it is difficult for clinicians to render a correct evaluation of the status of the vaginal flora.
Pre-clinical toxicology considerations for vaccine development.
Al-Humadi, Nabil
2017-10-13
Vaccine development requires pre-clinical toxicology studies, following good laboratory practice (GLP), before first in human (phase I) use. Many factors are critical in the final outcome of any pre-clinical toxicology study. The study design is one of these critical factors and should be carefully planned to avoid any false negative and/or false positive results. Preparation is another most critical factor in a successful study. Major changes in any procedure during the course of study should be avoided by all means. For example, if the protocol specified the tail as the site of blood collection and this procedure was used for the control group at the day of necropsy, this collection site should never be replaced by another site (e.g. foot, eye, or heart) in all other treatment groups. Food restrictions and acute restraint stress affect clinical pathology data and should be avoided in rodents. Institutional Animal Care and Use Committee (IACUC) guidelines for frequent blood collections (weekly, monthly, or at necropsy) in any animal species should be strictly followed. Clinical pathology data will be profoundly affected by any diversion from the recommended volumes. If CO 2 is specified in the protocol for anesthesia and/or euthanasia, ensuring enough quantity to use for all groups at necropsy is a very important factor. Using two different anesthetics in any study (e.g. CO 2 vs. pentobarbital) may result in false positive or false negative results in clinical chemistry parameters. Quality assurance elements (SOPs, instrument validation, lab certification etc.) affect the data interpretation and the final outcome of any toxicology study. SOPs should be up to date and written clearly. All lab instruments should be validated and all laboratories should be certified. Published by Elsevier Ltd.
Omitting duodenal biopsy in children with suspected celiac disease and extra-intestinal symptoms.
Bozzola, Mauro; Meazza, Cristina; Gertosio, Chiara; Pagani, Sara; Larizza, Daniela; Calcaterra, Valeria; Luinetti, Ombretta; Farello, Giovanni; Tinelli, Carmine; Iughetti, Lorenzo
2017-07-15
The aim of our study is to evaluate if in children with highly positive serology and HLA-DQ2/DQ8 (triple test, TT) and only extra-intestinal symptoms, it is possible to omit performing an intestinal biopsy for celiac disease (CD) diagnosis, as suggested by the new European Society for Pediatric Gastroenterology, Hepatology and Nutrition ESPGHAN guidelines. In this retrospective study a total of 105 patients, suspected of having CD because of extra-intestinal symptoms and showing serum tissue transglutaminase antibody (anti-tTG) and anti-endomysial antibody (EMA) measurements and HLA genotyping, were considered for the final analysis (33 boys and 72 girls; age range 1.5-17.6 years). Histological findings confirmed diagnosis of CD in 97 (92.4%) patients. Forty-one patients (39%) showed anti-tTG >10 times normal values, positive EMA and positive HLA-DQ2/DQ8 (positive TT). All of them had a diagnosis of CD, therefore there were no false positive cases. Sixty-four patients were negative for the TT. In eight cases, CD was ruled out and these were considered true negative cases. In the remaining 56 negative TT patients, intestinal biopsy confirmed CD diagnosis and they were considered false negatives. Based on these results, specificity for the TT was 100% and sensitivity was 42.3%. On the basis of the present study, diagnosis of CD can be reliably performed without a duodenal biopsy in children with only extra-intestinal symptoms.
Sánchez-Villalobos, Alfredo; Urdaneta-Fernández, Margelys; Rubio-Fuenmayor, Elí; Molero-Saras, Gladys; Luzardo-Charris, Carlos; Corona-Mengual, Carlos
2011-03-01
In order to show the development and scope of a serological analysis method based on fluorescence polarization assay (FPA) from a drop of blood obtained by the capillary technique, a Brucella antibody assay was performed on a group of 321 high-risk workers. The results were compared with data from the analysis of blood serum by FPA and a competitive enzyme immunoassay (ELISA-c). The number of concordance was 318 (99.06%), and discordant 3 (0.93%), which were negative in serum by fluorescence polarization (FPAs) and ELISA-c, but positive with capillary FPA (FPAc). The comparative results FPAc were: sensitivity 100%; specificity: 99.05%; positive predictive value 66.67%; negative predictive value 100.0%; false positive rate: 0.95%; false negative rate: 0%; accuracy: 98.0%; odds ratio: 203.00. The youden J for both FPA methods was 0.667. The identification was considered reliable and the correlation of both procedures, FPA and ELISA-c, was no statistically different (P > 0.05%), which allows to highly recommend the study implementation of human brucellosis with capillary blood as a preliminary method.
Arousal-But Not Valence-Reduces False Memories at Retrieval.
Mirandola, Chiara; Toffalini, Enrico
2016-01-01
Mood affects both memory accuracy and memory distortions. However, some aspects of this relation are still poorly understood: (1) whether valence and arousal equally affect false memory production, and (2) whether retrieval-related processes matter; the extant literature typically shows that mood influences memory performance when it is induced before encoding, leaving unsolved whether mood induced before retrieval also impacts memory. We examined how negative, positive, and neutral mood induced before retrieval affected inferential false memories and related subjective memory experiences. A recognition-memory paradigm for photographs depicting script-like events was employed. Results showed that individuals in both negative and positive moods-similar in arousal levels-correctly recognized more target events and endorsed fewer false memories (and these errors were linked to remember responses less frequently), compared to individuals in neutral mood. This suggests that arousal (but not valence) predicted memory performance; furthermore, we found that arousal ratings provided by participants were more adequate predictors of memory performance than their actual belonging to either positive, negative or neutral mood groups. These findings suggest that arousal has a primary role in affecting memory, and that mood exerts its power on true and false memory even when induced at retrieval.
Arousal—But Not Valence—Reduces False Memories at Retrieval
Mirandola, Chiara; Toffalini, Enrico
2016-01-01
Mood affects both memory accuracy and memory distortions. However, some aspects of this relation are still poorly understood: (1) whether valence and arousal equally affect false memory production, and (2) whether retrieval-related processes matter; the extant literature typically shows that mood influences memory performance when it is induced before encoding, leaving unsolved whether mood induced before retrieval also impacts memory. We examined how negative, positive, and neutral mood induced before retrieval affected inferential false memories and related subjective memory experiences. A recognition-memory paradigm for photographs depicting script-like events was employed. Results showed that individuals in both negative and positive moods–similar in arousal levels–correctly recognized more target events and endorsed fewer false memories (and these errors were linked to remember responses less frequently), compared to individuals in neutral mood. This suggests that arousal (but not valence) predicted memory performance; furthermore, we found that arousal ratings provided by participants were more adequate predictors of memory performance than their actual belonging to either positive, negative or neutral mood groups. These findings suggest that arousal has a primary role in affecting memory, and that mood exerts its power on true and false memory even when induced at retrieval. PMID:26938737
Comparing diagnostic tests on benefit-risk.
Pennello, Gene; Pantoja-Galicia, Norberto; Evans, Scott
2016-01-01
Comparing diagnostic tests on accuracy alone can be inconclusive. For example, a test may have better sensitivity than another test yet worse specificity. Comparing tests on benefit risk may be more conclusive because clinical consequences of diagnostic error are considered. For benefit-risk evaluation, we propose diagnostic yield, the expected distribution of subjects with true positive, false positive, true negative, and false negative test results in a hypothetical population. We construct a table of diagnostic yield that includes the number of false positive subjects experiencing adverse consequences from unnecessary work-up. We then develop a decision theory for evaluating tests. The theory provides additional interpretation to quantities in the diagnostic yield table. It also indicates that the expected utility of a test relative to a perfect test is a weighted accuracy measure, the average of sensitivity and specificity weighted for prevalence and relative importance of false positive and false negative testing errors, also interpretable as the cost-benefit ratio of treating non-diseased and diseased subjects. We propose plots of diagnostic yield, weighted accuracy, and relative net benefit of tests as functions of prevalence or cost-benefit ratio. Concepts are illustrated with hypothetical screening tests for colorectal cancer with test positive subjects being referred to colonoscopy.
A case of placental trisomy 18 mosaicism causing a false negative NIPT result.
Yang, Jiexia; Qi, Yiming; Guo, Fangfang; Hou, Yaping; Peng, Haishan; Wang, Dongmei; Oy, Haoxin; Yin, Aihua
2017-01-01
The non-invasive prenatal testing that evaluates circulating cell free DNA, and has been established as an additional pregnancy test for detecting the common fetal trisomies 21, 18 and 13 is rapidly revolutionizing prenatal screening as a result of its increased sensitivity and specificity. However, false positive and false negative results still exist. We presented a case in which the non-invasive prenatal testing results were normal at 15 gestational age (GA), but an ultrasound examination at 30GA showed that the fetus had heart abnormalities, and the third trimester ultrasound at 33GA noted multiple anomalies including a 3.0 mm ventricular septal defect. Along with cordocentesis at 33GA, the cord blood sample cytogenetics analysis showed a mos 47,XN,+18[61]/46,XN[39] T18 karyotype. Six placental biopsies confirmed that the chromosome 18 placenta chimerism ratio had changed from 33% to 72%. Ultimately, the pregnancy was interrupted at 34GA. We presented this case to highlight the need to clearly explain false positive or false negative results to patients. We believe that this information will also influence the development of future diagnostic test methodologies.
Rapid automated method for screening of enteric pathogens from stool specimens.
Villasante, P A; Agulla, A; Merino, F J; Pérez, T; Ladrón de Guevara, C; Velasco, A C
1987-01-01
A total of 800 colonies suggestive of Salmonella, Shigella, or Yersinia species isolated on stool differential agar media were inoculated onto both conventional biochemical test media (triple sugar iron agar, urea agar, and phenylalanine agar) and Entero Pathogen Screen cards of the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). Based on the conventional tests, the AutoMicrobic system method yielded the following results: 587 true-negatives, 185 true-positives, 2 false-negatives, and 26 false-positives (sensitivity, 99%; specificity, 96%). Both true-positive and true-negative results were achieved considerably earlier than false results (P less than 0.001). The Entero Pathogen Screen card method is a fast, easy, and sensitive method for screening for Salmonella, Shigella, or Yersinia species. The impossibility of screening for oxidase-positive pathogens is a minor disadvantage of this method. PMID:3553230
Performance of Momguard, a new non-invasive prenatal testing protocol developed in Korea.
Lee, Mi-Young; Cho, Dae-Yeon; Won, Hye-Sung; Hwang, Ah Reum; Jeong, Bada; Kim, Jihun; Oh, Mijin
2015-09-01
To evaluate the performance of Momguard, non-invasive prenatal test (NIPT) for detecting trisomy (T) 21, T18, T13, and sex-chromosome abnormalities recently developed in Korea. This preliminary study formed part of a large prospective cohort study conducted at Asan Medical Center, Seoul, Korea. Only pregnant women who underwent both NIPT and confirmatory karyotyping were included in this study. NIPT results were compared with those of karyotype analyses. Among 93 eligible cases, NIPT results could not be obtained in one case due to a low fetal cell-free DNA fraction. Based on NIPT, eight cases of fetal aneuploidies, including T21 (n=5), T18 (n=2), and T13 (n=1), were identified. For T21 and T18, the sensitivity and specificity of NIPT were both 100%, with a false-positive and false-negative rate of 0% and a positive-predictive value of 100%. One patient classified as having intermediate risk for T13 by NIPT was confirmed to have T13 by karyotyping, and there were no false-negative cases. No cases of sex-chromosome anomalies were detected by NIPT or karyotyping during the study period. Momguard is a reliable screening tool for detecting T21 and T18. For T13 and sex-chromosome anomalies, further prospective studies are necessary to confirm its utility.
Mobile natural gas leak surveys indicate that two utilities have high false negative rates
NASA Astrophysics Data System (ADS)
von Fischer, J. C.; Brewer, P. E.; Chamberlain, S.; Gaylord, A.; von Fischer, J.
2016-12-01
In the distribution systems that carry natural gas to consumers, leaks need to be discovered for safety reasons and to reduce greenhouse gas emissions. However, few utilities have adopted newer laser-based technologies that have greater sensitivity and precision, and instead rely on "industry standard" equipment that is far less sensitive. In partnership with the Environmental Defense Fund and Google, we mapped natural gas leaks in the domains of two anonymous utilities (Utility "A" and "B") using high sensitivity Picarro methane analyzers in Google Street View Cars. Surprisingly, when we shared these results with utilities, their survey crews were unable to find most of the leaks that our survey indicated (84% in A and 80% in B). To investigate this phenomenon, our team visited a subset of the leaks in each utility domain (n=32 in A and n=30 in B), and worked alongside utility surveyors to search the leak indication area, using a Los Gatos Research ultraportable methane analyzer to pinpoint leak locations. We found evidence of natural gas leaks at 69% and 68% of the locations in Utilities A and B respectively where survey crews had found nothing. We describe this as a "false negative" rate for the utility because the utility survey falsely indicated that there was no leak at these locations. Of these false negatives, 7% (n=2 of 32 in A, n=2 of 30 in B) were determined to be Grade 1 leaks requiring immediate repair due to high safety risk. Instrument sensitivity appears to explain some of the false negative rates. In particular, use of some industry standard equipment appears to have created a false sense of confidence among utility surveyors that leaks were not present. However, there was also evidence of communication failures and that surveyors did not use optimal approaches in their search. Based on these findings, we suggest that: 1) mobile deployment of high-precision methane analyzers can help find more natural gas leaks, and 2) use of some hand-held survey instruments may lead to higher rates of false negatives in leak survey and 3) there may be room for improvement in leak survey methodologies.
Makkar, Steve R; Grisham, Jessica R
2013-03-01
Current social phobia models (e.g., Clark & Wells, 1995; Leary & Kowalski, 1995) postulate that socially anxious individuals negatively appraise their anxiety sensations (e.g., sweating, heart racing, blushing) as evidence of poor social performance, and thus fear these anxiety symptoms will be noticed and judged negatively by others. Consequently, they become self-focused and hypervigilant of these sensations and use them to judge how they appear to others. To test this model, high (N=41) and low (N=38) socially anxious participants were shown false physiological feedback regarding an increase or decrease in heart rate prior to and during an impromptu speech task. Relative to participants who observed a false heart rate decrease, those in the increase condition reported higher levels of negative affect, more negative performance appraisals, and more frequent negative ruminative thoughts, and these effects were mediated by an increase in self-focused attention. The unhelpful effects of the physiological feedback were not specific to high socially anxious participants. The results have implications for current cognitive models as well as the treatment of social phobia. Copyright © 2012. Published by Elsevier Ltd.
Gubern-Mérida, Albert; Vreemann, Suzan; Martí, Robert; Melendez, Jaime; Lardenoije, Susanne; Mann, Ritse M; Karssemeijer, Nico; Platel, Bram
2016-02-01
To evaluate the performance of an automated computer-aided detection (CAD) system to detect breast cancers that were overlooked or misinterpreted in a breast MRI screening program for women at increased risk. We identified 40 patients that were diagnosed with breast cancer in MRI and had a prior MRI examination reported as negative available. In these prior examinations, 24 lesions could retrospectively be identified by two breast radiologists in consensus: 11 were scored as visible and 13 as minimally visible. Additionally, 120 normal scans were collected from 120 women without history of breast cancer or breast surgery participating in the same MRI screening program. A fully automated CAD system was applied to this dataset to detect malignant lesions. At 4 false-positives per normal case, the sensitivity for the detection of cancer lesions that were visible or minimally visible in retrospect in prior-negative examinations was 0.71 (95% CI=0.38-1.00) and 0.31 (0.07-0.59), respectively. A substantial proportion of cancers that were misinterpreted or overlooked in an MRI screening program was detected by a CAD system in prior-negative examinations. It has to be clarified with further studies if such a CAD system has an influence on the number of misinterpreted and overlooked cancers in clinical practice when results are given to a radiologist. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
2014-01-01
Introduction Interval cancers are tumors arising after a negative screening episode and before the next screening invitation. They can be classified into true interval cancers, false-negatives, minimal-sign cancers, and occult tumors based on mammographic findings in screening and diagnostic mammograms. This study aimed to describe tumor-related characteristics and the association of breast density and tumor phenotype within four interval cancer categories. Methods We included 2,245 invasive tumors (1,297 screening-detected and 948 interval cancers) diagnosed from 2000 to 2009 among 645,764 women aged 45 to 69 who underwent biennial screening in Spain. Interval cancers were classified by a semi-informed retrospective review into true interval cancers (n = 455), false-negatives (n = 224), minimal-sign (n = 166), and occult tumors (n = 103). Breast density was evaluated using Boyd’s scale and was conflated into: <25%; 25 to 50%; 50 to 75%; >75%. Tumor-related information was obtained from cancer registries and clinical records. Tumor phenotype was defined as follows: luminal A: ER+/HER2- or PR+/HER2-; luminal B: ER+/HER2+ or PR+/HER2+; HER2: ER-/PR-/HER2+; triple-negative: ER-/PR-/HER2-. The association of tumor phenotype and breast density was assessed using a multinomial logistic regression model. Adjusted odds ratios (OR) and 95% confidence intervals (95% CI) were calculated. All statistical tests were two-sided. Results Forty-eight percent of interval cancers were true interval cancers and 23.6% false-negatives. True interval cancers were associated with HER2 and triple-negative phenotypes (OR = 1.91 (95% CI:1.22-2.96), OR = 2.07 (95% CI:1.42-3.01), respectively) and extremely dense breasts (>75%) (OR = 1.67 (95% CI:1.08-2.56)). However, among true interval cancers a higher proportion of triple-negative tumors was observed in predominantly fatty breasts (<25%) than in denser breasts (28.7%, 21.4%, 11.3% and 14.3%, respectively; <0.001). False-negatives and occult tumors had similar phenotypic characteristics to screening-detected cancers, extreme breast density being strongly associated with occult tumors (OR = 6.23 (95% CI:2.65-14.66)). Minimal-sign cancers were biologically close to true interval cancers but showed no association with breast density. Conclusions Our findings revealed that both the distribution of tumor phenotype and breast density play specific and independent roles in each category of interval cancer. Further research is needed to understand the biological basis of the overrepresentation of triple-negative phenotype among predominantly fatty breasts in true interval cancers. PMID:24410848
Police Officer Schema of Sexual Assault Reports: Real Rape, Ambiguous Cases, and False Reports.
Venema, Rachel M
2016-03-01
While extensive research has studied sexual assault reporting behaviors and described negative experiences with the criminal justice system among victim-survivors, fewer studies have explored police officer attitudes, knowledge, and thought processes that may affect victims' perceptions of negative interactions and unsatisfactory outcomes within reported sexual assault cases. This study explores police officer understanding of the definition of sexual assault and characteristics that influence their perceptions and response. Ten police officers were interviewed within one police department in a midsized city in the Great Lakes region. The study uses a modified grounded theory approach. Findings suggest that officers employ distinct schema of reported sexual assaults. Case characteristics, perceived credibility of the victim, and types of evidence formed categorizations of false reports, ambiguous cases, and legitimate sexual assaults. Police officers describe the ways in which perceptions of the case may or may not influence the response and point to areas for improvement within police procedure. The study findings provide insight into recommendations for improved police interviewing and response to reported sexual assaults. © The Author(s) 2014.
Parry, John V; Easterbrook, Philippa; Sands, Anita R
2017-11-01
Initial serological testing for chronic hepatitis B virus (HBV) and hepatitis C virus (HCV) infection is conducted using either rapid diagnostic tests (RDT) or laboratory-based enzyme immunoassays (EIA)s for detection of hepatitis B surface antigen (HBsAg) or antibodies to HCV (anti-HCV), typically on serum or plasma specimens and, for certain RDTs, capillary whole blood. WHO recommends the use of standardized testing strategies - defined as a sequence of one or more assays to maximize testing accuracy while simplifying the testing process and ideally minimizing cost. Our objective was to examine the diagnostic outcomes of a one- versus two-assay serological testing strategy. These data were used to inform recommendations in the 2017 WHO Guidelines on hepatitis B and C testing. Few published studies have compared diagnostic outcomes for one-assay versus two-assay serological testing strategies for HBsAg and anti-HCV. Therefore, the principles of Bayesian statistics were used to conduct a modelling exercise to examine the outcomes of a one-assay versus two-assay testing strategy when applied to a hypothetical population of 10,000 individuals. The resulting model examined the diagnostic outcomes (true and false positive diagnoses; true and false negative diagnoses; positive and negative predictive values as a function of prevalence; and total tests required) for both one-assay and two-assay testing strategies. The performance characteristics assumed for assays used within the testing strategies were informed by WHO prequalification assessment findings and systematic reviews for diagnostic accuracy studies. Each of the presumptive testing strategies (one-assay or two-assay) was modelled at varying prevalences of HBsAg (10%, 2% and 0.4%) and of anti-HCV (40%, 10%, 2% and 0.4%), aimed at representing the range of testing populations typically encountered in WHO Member States. When the two-assay testing strategy was considered, the model assumed the independence of the two assays. Modeling demonstrated that applying a single assay (HBsAg or anti-HCV), even with high specificity (99%), may result in considerable numbers of false positive diagnoses and low positive predictive values (PPV), particularly in lower prevalence settings. Even at very low prevalences shifting to a two-assay testing strategy would result in a PPV approaching 1.0. When test sensitivity is high (>99%) false negative reactions are rare at all but the highest prevalences; but a two-test strategy might yield more false negative diagnoses. The order in which the tests are used has no impact on the overall accuracy of a two-assay strategy though it may impact the total number of tests needed to complete the diagnostic strategy, incurring added cost and complexity. HBsAg assays may have a low sensitivity (<90%), and result in large numbers of false negative diagnoses, particularly in high prevalence settings, which would be exacerbated in the two-assay testing strategy. In contrast, most anti-HCV assays have high sensitivity and lead to fewer false negative results, both in the one-assay and two-assay testing strategies. At prevalences ≤2% the number of tests needed using a second assay was nearly always small, at <300 per 10,000 individuals tested, making sustainability of a second assay uncertain in such a setting. A key public health objective of an effective testing strategy is to identify all individuals who would benefit from treatment. Therefore, a strategy that prioritizes a high NPV (minimal false negatives) may be acceptable even if the PPV is suboptimal (some false positives) as the implementation of such a public health programme must also take account of other factors such as costs, feasibility, impact on testing uptake and linkage to care, and consequences of a false-positive test. This rationale informed the development of the WHO Viral Hepatitis Testing Guidelines, with a conditional recommendation for a one-assay serological testing strategy in most testing settings and populations (≥0.4% prevalence in population tested). A one-test strategy results in few failures to diagnose infection and, although it is associated under most assumptions with a sub-optimal PPV, benefits include greater simplicity, easier implementation, lower costs and better feasibility, uptake and linkage to care. Furthermore, prior to antiviral therapy all those diagnosed either HBsAg or anti-HCV positive will require confirmation of viræmia, preventing unnecessary treatment of those who may be false positive on serology. For HBsAg, in low-prevalence settings (≤0.4%), a second recommendation was made to consider a two-assay testing strategy, using a confirmatory neutralization step or a second different HBsAg assay.
Berhane, Araia; Anderson, Karen; Mihreteab, Selam; Gresty, Karryn; Rogier, Eric; Mohamed, Salih; Hagos, Filmon; Embaye, Ghirmay; Chinorumba, Anderson; Zehaie, Assefash; Dowd, Simone; Waters, Norman C.; Gatton, Michelle L.; Udhayakumar, Venkatachalam; Cunningham, Jane
2018-01-01
False-negative results for Plasmodium falciparum histidine-rich protein (HRP) 2–based rapid diagnostic tests (RDTs) are increasing in Eritrea. We investigated HRP gene 2/3 (pfhrp2/pfhrp3) status in 50 infected patients at 2 hospitals. We showed that 80.8% (21/26) of patients at Ghindae Hospital and 41.7% (10/24) at Massawa Hospital were infected with pfhrp2-negative parasites and 92.3% (24/26) of patients at Ghindae Hospital and 70.8% (17/24) at Massawa Hospital were infected with pfhrp3-negative parasites. Parasite densities between pfhrp2-positive and pfhrp2-negative patients were comparable. All pfhrp2-negative samples had no detectable HRP2/3 antigen and showed negative results for HRP2-based RDTs. pfhrp2-negative parasites were genetically less diverse and formed 2 clusters with no close relationships to parasites from Peru. These parasites probably emerged independently by selection in Eritrea. High prevalence of pfhrp2-negative parasites caused a high rate of false-negative results for RDTs. Determining prevalence of pfhrp2-negative parasites is urgently needed in neighboring countries to assist case management policies. PMID:29460730
Berhane, Araia; Anderson, Karen; Mihreteab, Selam; Gresty, Karryn; Rogier, Eric; Mohamed, Salih; Hagos, Filmon; Embaye, Ghirmay; Chinorumba, Anderson; Zehaie, Assefash; Dowd, Simone; Waters, Norman C; Gatton, Michelle L; Udhayakumar, Venkatachalam; Cheng, Qin; Cunningham, Jane
2018-03-01
False-negative results for Plasmodium falciparum histidine-rich protein (HRP) 2-based rapid diagnostic tests (RDTs) are increasing in Eritrea. We investigated HRP gene 2/3 (pfhrp2/pfhrp3) status in 50 infected patients at 2 hospitals. We showed that 80.8% (21/26) of patients at Ghindae Hospital and 41.7% (10/24) at Massawa Hospital were infected with pfhrp2-negative parasites and 92.3% (24/26) of patients at Ghindae Hospital and 70.8% (17/24) at Massawa Hospital were infected with pfhrp3-negative parasites. Parasite densities between pfhrp2-positive and pfhrp2-negative patients were comparable. All pfhrp2-negative samples had no detectable HRP2/3 antigen and showed negative results for HRP2-based RDTs. pfhrp2-negative parasites were genetically less diverse and formed 2 clusters with no close relationships to parasites from Peru. These parasites probably emerged independently by selection in Eritrea. High prevalence of pfhrp2-negative parasites caused a high rate of false-negative results for RDTs. Determining prevalence of pfhrp2-negative parasites is urgently needed in neighboring countries to assist case management policies.
Edwards, Jeffrey K; Kleine, Christian; Munster, Vincent; Giuliani, Ruggero; Massaquoi, Moses; Sprecher, Armand; Chertow, Daniel S
2015-12-01
Quantitative reverse-transcription polymerase chain reaction (qRT-PCR) is the most sensitive quantitative diagnostic assay for detection of Ebola virus in multiple body fluids. Despite the strengths of this assay, we present 2 cases of Ebola virus disease (EVD) and highlight the potential for false-negative results during the early and late stages of EVD. The first case emphasizes the low negative-predictive value of qRT-PCR during incubation and the early febrile stage of EVD, and the second case emphasizes the potential for false-negative results during recovery and late neurologic complications of EVD. Careful interpretation of test results are needed to guide difficult admission and discharge decisions in suspected or confirmed EVD.
Testing the validity of a continuous false belief task in 3- to 7-year-old children.
Mahy, Caitlin E V; Bernstein, Daniel M; Gerrard, Lindsey D; Atance, Cristina M
2017-08-01
In two studies, we examined young children's performance on the paper-and-pencil version of the Sandbox task, a continuous measure of false belief, and its relations with other false belief and inhibition tasks. In Study 1, 96 children aged 3 to 7years completed three false belief tasks (Sandbox, Unexpected Contents, and Appearance/Reality) and two inhibition tasks (Head-Shoulders-Knees-Toes and Grass/Snow). Results revealed that false belief bias-a measure of egocentrism-on the Sandbox task correlated with age but not with the Unexpected Contents or Appearance/Reality task or with measures of inhibition after controlling for age. In Study 2, 90 3- to 7-year-olds completed five false belief tasks (Sandbox, Unexpected Contents, Appearance/Reality, Change of Location, and a second-order false belief task), two inhibition tasks (Simon Says and Grass/Snow), and a receptive vocabulary task (Peabody Picture Vocabulary Test). Results showed that false belief bias on the Sandbox task correlated negatively with age and with the Change of Location task but not with the other false belief or inhibition tasks after controlling for age and receptive vocabulary. The Sandbox task shows promise as an age-sensitive measure of false belief performance during early childhood and shows convergent and discriminant validity. Copyright © 2017 Elsevier Inc. All rights reserved.
7 CFR 275.13 - Review of negative cases.
Code of Federal Regulations, 2010 CFR
2010-01-01
... household which was listed incorrectly in the negative frame. (f) Demonstration projects/SSA processing. A... 7 Agriculture 4 2010-01-01 2010-01-01 false Review of negative cases. 275.13 Section 275.13... § 275.13 Review of negative cases. (a) General. A sample of households whose applications for food stamp...
Optimization and validation of CEDIA drugs of abuse immunoassay tests in serum on Hitachi 912.
Kirschbaum, Katrin M; Musshoff, Frank; Schmithausen, Ricarda; Stockhausen, Sarah; Madea, Burkhard
2011-10-10
Due to sensitive limits of detection of chromatographic methods and low limit values regarding the screening of drugs under the terms of impairment in safe driving (§ 24a StVG, Street Traffic Law in Germany), preliminary immunoassay (IA) tests should be able to detect also low concentrations of legal and illegal drugs in serum in forensic cases. False-negatives should be avoided, the rate of false-positive samples should be low due to cost and time. An optimization of IA cutoff values and a validation of the assay is required for each laboratory. In a retrospective study results for serum samples containing amphetamine, methylenedioxy derivatives, cannabinoids, benzodiazepines, cocaine (metabolites), methadone and opiates obtained with CEDIA drugs of abuse reagents on a Hitachi 912 autoanalyzer were compared with quantitative results of chromatographic methods (gas or liquid chromatography coupled with mass spectrometry (GC/MS or LC/MS)). Firstly sensitivity, specificity, positive and negative predictive values and overall misclassification rates were evaluated by contingency tables and compared to ROC-analyses and Youden-Indices. Secondly ideal cutoffs were statistically calculated on the basis of sensitivity and specificity as decisive statistical criteria with focus on a high sensitivity (low rates of false-negatives), i.e. using the Youden-Index. Immunoassay (IA) and confirmatory results were available for 3014 blood samples. Sensitivity was 90% or more for nearly all analytes: amphetamines (IA cutoff 9.5 ng/ml), methylenedioxy derivatives (IA cutoff 5.5 ng/ml), cannabinoids (IA cutoff 14.5 ng/ml), benzodiazepines (IA cutoff >0 ng/ml). Test of opiates showed a sensitivity of 86% for a IA cutoff value of >0 ng/ml. Values for specificity ranged between 33% (methadone, IA cutoff 10 ng/ml) and 90% (cocaine, IA cutoff 20 ng/ml). Lower cutoff values as recommended by ROC analyses were chosen for most tests to decrease the rate of false-negatives. Analyses enabled the definition of cutoff values with good values for sensitivity. Small rates of false-positives can be accepted in forensic cases. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Ndase, Patrick; Celum, Connie; Kidoguchi, Lara; Ronald, Allan; Fife, Kenneth H; Bukusi, Elizabeth; Donnell, Deborah; Baeten, Jared M
2015-01-01
Rapid HIV assays are the mainstay of HIV testing globally. Delivery of effective biomedical HIV prevention strategies such as antiretroviral pre-exposure prophylaxis (PrEP) requires periodic HIV testing. Because rapid tests have high (>95%) but imperfect specificity, they are expected to generate some false positive results. We assessed the frequency of true and false positive rapid results in the Partners PrEP Study, a randomized, placebo-controlled trial of PrEP. HIV testing was performed monthly using 2 rapid tests done in parallel with HIV enzyme immunoassay (EIA) confirmation following all positive rapid tests. A total of 99,009 monthly HIV tests were performed; 98,743 (99.7%) were dual-rapid HIV negative. Of the 266 visits with ≥1 positive rapid result, 99 (37.2%) had confirmatory positive EIA results (true positives), 155 (58.3%) had negative EIA results (false positives), and 12 (4.5%) had discordant EIA results. In the active PrEP arms, over two-thirds of visits with positive rapid test results were false positive results (69.2%, 110 of 159), although false positive results occurred at <1% (110/65,945) of total visits. When HIV prevalence or incidence is low due to effective HIV prevention interventions, rapid HIV tests result in a high number of false relative to true positive results, although the absolute number of false results will be low. Program roll-out for effective interventions should plan for quality assurance of HIV testing, mechanisms for confirmatory HIV testing, and counseling strategies for persons with positive rapid test results.
Van Bergen, Saskia; Jelicic, Marko; Merckelbach, Harald
2009-01-01
The relationship between subjective memory beliefs and suggestibility, compliance, false memories, and objective memory performance was studied in a community sample of young and middle-aged people (N = 142). We hypothesized that people with subjective memory problems would exhibit higher suggestibility and compliance levels and would be more susceptible to false recollections than those who are optimistic about their memory. In addition, we expected a discrepancy between subjective memory judgments and objective memory performance. We found that subjective memory judgments correlated significantly with compliance, with more negative memory judgments accompanying higher levels of compliance. Contrary to our expectation, subjective memory problems did not correlate with suggestibility or false recollections. Furthermore, participants were accurate in estimating their objective memory performance.
Role of Urine Drug Testing in the Current Opioid Epidemic.
Mahajan, Gagan
2017-12-01
While the evidence for urine drug testing for patients on chronic opioid therapy is weak, the guidelines created by numerous medical societies and state and federal regulatory agencies recommend that it be included as one of the tools used to monitor patients for compliance with chronic opioid therapy. To get the most comprehensive results, clinicians should order both an immunoassay screen and confirmatory urine drug test. The immunoassay screen, which can be performed as an in-office point-of-care test or as a laboratory-based test, is a cheap and convenient study to order. Limitations of an immunoassay screen, however, include having a high threshold of detectability and only providing qualitative information about a select number of drug classes. Because of these restrictions, clinicians should understand that immunoassay screens have high false-positive and false-negative rates. Despite these limitations, though, the results can assist the clinician with making preliminary treatment decisions. In comparison, a confirmatory urine drug test, which can only be performed as a laboratory-based test, has a lower threshold of detectability and provides both qualitative and quantitative information. A urine drug test's greater degree of specificity allows for a relatively low false-negative and false-positive rate in contrast to an immunoassay screen. Like any other diagnostic test, an immunoassay screen and a confirmatory urine drug test both possess limitations. Clinicians must keep this in mind when interpreting an unexpected test result and consult with their laboratory when in doubt about the meaning of the test result to avoid making erroneous decisions that negatively impact both the patient and clinician.
Evaluation of negative results of BacT/Alert 3D automated blood culture system.
Kocoglu, M Esra; Bayram, Aysen; Balci, Iclal
2005-06-01
Although automated continuous-monitoring blood culture systems are both rapid and sensitive, false-positive and false-negative results still occur. The objective of this study, then, was to evaluate negative results occurring with BacT/Alert 3D blood culture systems. A total of 1032 samples were cultured with the BacT/Alert 3D automated blood culture system, using both aerobic (FA) and anaerobic (FN) [corrected] media, and 128 of these samples yielded positive results. A total of 904 negative blood samples were then subcultured in 5% sheep blood agar, eosin methylene blue, chocolate agar, and sabouraud-dextrose agar. Organisms growing on these subcultures were subsequently identified using both Vitek32 (bioMerieux, Durham, NC) and conventional methods. Twenty four (2.6%) of the 904 subcultures grew on the subculture media. The majority (83.3%) of these were determined to be gram-positive microorganisms. Fourteen (58.3%) were coagulase-negative staphylococci, two (8.3%) were Bacillus spp., one (4.2%) was Staphylococcus aureus, and one (4.2%) was identified as Enterococcus faecium. Streptococcus pneumoniae and Neisseria spp. were isolated together in two (8.3%) vials. Gram-negative microorganisms comprised 12.5% of the subcultures, of which two (8.3%) were found to be Pseudomonas aeruginosa, and one (4.2%) was Pseudomonas fluorescens. The other isolate (4.2%) was identified as Candida albicans. We conclude that the subculture of negative results is valuable in the BacT/Alert 3D system, especially in situations in which only one set of blood cultures is taken.
Clinical significance of FDG-PET/CT at the postoperative surveillance in the breast cancer patients.
Jung, Na Young; Yoo, Ie Ryung; Kang, Bong Joo; Kim, Sung Hun; Chae, Byung Joo; Seo, Ye Young
2016-01-01
We evaluated the clinical role of [(18)F]-2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (FDG-PET/CT) compared with conventional imaging (CI) to detect locoregional recurrence or distant metastasis during postoperative surveillance of patients with breast cancer. We included 1,819 examinations of 1,161 patients, who underwent FDG-PET/CT and CI, including mammography, breast ultrasound, whole-body bone scintigraphy, and chest radiography for postoperative surveillance. All patients had a history of surgery with or without adjuvant treatment due to more than stage II breast cancer between November 2003 and November 2009. We evaluated the diagnostic performance of CI, FDG-PET/CT, and combined CI and FDG-PET/CT for detecting locoregional recurrence, distant metastasis, and incidental cancer. We also analyzed false-positive and false-negative results in both FDG-PET/CT and CI. Sensitivity, specificity, positive predictive value, and negative predictive value of CI were 75.4, 98.7, 93.4, and 94.3 %. Those of FDG-PET/CT were 97.5, 98.8, 95.4, and 99.4 %. Those of the combined results were 98.6, 98.2, 96.7, and 99.7 %. Sensitivity of FDG-PET/CT was significantly higher than that of CI (P < 0.05). Sensitivity of combined CI and FDG-PET/CT results improved, but they were not significantly different from those of FDG-PET/CT alone (P = 0.43). Seventeen false-positive and nine false-negative cases were detected with FDG-PET/CT, and 19 false-positive and 88 false-negative cases were detected with CI. FDG-PET/CT is considered as an acceptable diagnostic imaging modality for postoperative surveillance of patients with breast cancer.
Raza, Shaan M; Banu, Matei A; Donaldson, Angela; Patel, Kunal S; Anand, Vijay K; Schwartz, Theodore H
2016-03-01
The intraoperative detection of CSF leaks during endonasal endoscopic skull base surgery is critical to preventing postoperative CSF leaks. Intrathecal fluorescein (ITF) has been used at varying doses to aid in the detection of intraoperative CSF leaks. However, the sensitivity and specificity of ITF at certain dosages is unknown. A prospective database of all endoscopic endonasal procedures was reviewed. All patients received 25 mg ITF diluted in 10 ml CSF and were pretreated with dexamethasone and Benadryl. Immediately after surgery, the operating surgeon prospectively noted if there was an intraoperative CSF leak and fluorescein was identified. The sensitivity, specificity, and positive and negative predictive power of ITF for detecting intraoperative CSF leak were calculated. Factors correlating with postoperative CSF leak were determined. Of 419 patients, 35.8% of patients did not show a CSF leak. Fluorescein-tinted CSF (true positive) was noted in 59.7% of patients and 0 false positives were encountered. CSF without fluorescein staining (false negative) was noted in 4.5% of patients. The sensitivity and specificity of ITF were 92.9% and 100%, respectively. The negative and positive predictive values were 88.8% and 100%, respectively. Postoperative CSF leaks only occurred in true positives at a rate of 2.8%. ITF is extremely specific and very sensitive for detecting intraoperative CSF leaks. Although false negatives can occur, these patients do not appear to be at risk for postoperative CSF leak. The use of ITF may help surgeons prevent postoperative CSF leaks by intraoperatively detecting and confirming a watertight repair.
40 CFR 62.2400 - Identification of plan-negative declaration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Identification of plan-negative declaration. 62.2400 Section 62.2400 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR....2400 Identification of plan—negative declaration. Letter from Florida Department of Environmental...
47 CFR 54.805 - Zone and study area above benchmark revenues calculated by the Administrator.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Period Residential and Single-Line Business Lines times 12. If negative, the Zone Above Benchmark...) multiplied by all eligible telecommunications carrier zone Base Period Multi-line Business Lines times 12. If... 47 Telecommunication 3 2010-10-01 2010-10-01 false Zone and study area above benchmark revenues...
False Negatives, Canter's Background Interference Procedure, the Trail Making Test, and Epileptics.
ERIC Educational Resources Information Center
McKinzey, Ronald K.; And Others
1985-01-01
Results of correlation studies of 141 adult epileptics' scores on the Background Interference Procedure (BIP) indicated that the BIP often does not agree with abnormal neurological diagnoses but often does agree with psychiatric diagnoses of Organic Brain Syndrome (OBS). Suggests that future BIP validity studies include a behavioral measure of OBS…
Publication bias and the canonization of false facts.
Nissen, Silas Boye; Magidson, Tali; Gross, Kevin; Bergstrom, Carl T
2016-12-20
Science is facing a "replication crisis" in which many experimental findings cannot be replicated and are likely to be false. Does this imply that many scientific facts are false as well? To find out, we explore the process by which a claim becomes fact. We model the community's confidence in a claim as a Markov process with successive published results shifting the degree of belief. Publication bias in favor of positive findings influences the distribution of published results. We find that unless a sufficient fraction of negative results are published, false claims frequently can become canonized as fact. Data-dredging, p-hacking, and similar behaviors exacerbate the problem. Should negative results become easier to publish as a claim approaches acceptance as a fact, however, true and false claims would be more readily distinguished. To the degree that the model reflects the real world, there may be serious concerns about the validity of purported facts in some disciplines.
Petrillo, Antonella; Fusco, Roberta; Petrillo, Mario; Triunfo, Flavia; Filice, Salvatore; Vallone, Paolo; Setola, Sergio Venanzio; Rubulotta, Mariarosaria; Di Bonito, Maurizio; Rinaldo, Massimo; D'Aiuto, Massimiliano; Brunetti, Arturo
2017-06-01
The purpose of this study was to evaluate the added value of breast magnetic resonance imaging (MRI) in preoperative diagnosis of ductal carcinoma in situ (DCIS). We reviewed our institution database of 3499 consecutive patients treated for breast cancer. A total of 362 patients with histologically proven DCIS were selected from the institutional database. Of these, 245 (67.7%) preoperatively underwent conventional imaging (CI) (mammography/ultrasonography) (CI group), and 117 (32.3%) underwent CI and dynamic MRI (CI + MRI group). The pathology of surgical specimens served as a reference standard. The Mann-Whitney U, χ 2 test, and Spearman correlation coefficient were performed. The CI + MRI group showed a sensitivity of 98.5% with an increase of 10.1% compared with the CI group to detect pure DCIS. Dynamic MRI identified 19.7% (n = 13) additional pure DCIS compared with CI. In the CI + MRI group, a single (1.5%) false negative was reported, whereas in the CI group, 11 (11.6%) false negatives were reported. Moreover, the CI + MRI group showed a sensitivity of 98.0% to detect DCIS + small invasive component. In this group, dynamic MRI identified 21.6% (n = 11) additional DCIS and a single (2.0%) false negative compared with the CI group, whereas in the CI group, 7 (4.7%) false negatives were reported. MRI and histopathologically measured lesion sizes, Breast Imaging Reporting and Data System MRI assessment categories, and enhancement signal intensity curve types showed a significant correlation. The MRI detection rate of DCIS increased significantly with increasing nuclear grade. Preoperative breast MRI showed a better accuracy then CI in preoperative diagnosis for both pure DCIS and DCIS + small invasive component with a precise assessment of lesion size. This can provide a more appropriate management of DCIS patients. Copyright © 2016 Elsevier Inc. All rights reserved.
Kwon, Hyuk-Jin; Yoo, Hee-Jeong; Kim, Joo-Hyun; Noh, Dong-Hyun; Sunwoo, Hyun-Jung; Jeon, Ye Seul; Lee, Sang-Youn; Jo, Ye-Ul; Bong, Gui-Young
2017-10-01
The current cut-off score of the Korean version of the Childhood Autism Rating Scale (K-CARS) does not seem to be sensitive enough to precisely diagnose high-functioning autism. The aim of this study was to identify the optimal cut-off score of K-CARS for diagnosing high-functioning individuals with autism spectrum disorders (ASD). A total of 329 participants were assessed by the Korean versions of the Autism Diagnostic Interview - Revised (K-ADI-R), Autism Diagnostic Observation Schedule (K-ADOS), and K-CARS. IQ and Social Maturity Scale scores were also obtained. The true positive and false negative rates of K-CARS were 77.2% and 22.8%, respectively. Verbal IQ (VIQ) and Social Quotient (SQ) were significant predictors of misclassification. The false negative rate increased to 36.0% from 19.8% when VIQ was >69.5, and the rate increased to 44.1% for participants with VIQ > 69.5 and SQ > 75.5. In addition, if SQ was >83.5, the false negative rate increased to 46.7%, even if the participant's VIQ was ≤69.5. Optimal cut-off scores were 28.5 (for VIQ ≤ 69.5 and SQ ≤ 75.5), 24.25 (for VIQ > 69.5 and SQ > 75.5), and 24.5 (for SQ > 83.5), respectively. The likelihood of a false negative error increases when K-CARS is used to diagnose high-functioning autism and Asperger's syndrome. For subjects with ASD and substantial verbal ability, the cut-off score for K-CARS should be re-adjusted and/or supplementary diagnostic tools might be needed to enhance diagnostic accuracy for ASD. © 2017 The Authors. Psychiatry and Clinical Neurosciences © 2017 Japanese Society of Psychiatry and Neurology.
Milhorn, Denise; Korpi-Steiner, Nichole
2015-02-01
It is unclear if the point-of-care (POC) Clinitest hCG device is subject to high-dose hook interference from physiological concentrations of intact human chorionic gonadotropin (hCG), β-core fragment of hCG (hCGβcf), and hCG free β-subunit (hCGβ) found in urine during pregnancy. We used a simulation model to address this question and related our findings to our institution's pregnant population in order to assess risk for potential false-negative hCG results. The expected distribution of days relative to ovulation during routine POC hCG testing was estimated from 182 patients. Clinitest-Clinitek Status hCG device susceptibility to high-dose hook interference from hCG variants and potential risk of false-negative results as it relates to this population were evaluated by testing increasing concentrations of hCG, hCGβcf, hCGβ as well as urine simulating physiological hCG, hCGβcf and hCGβ concentrations expected during early pregnancy (≤44 days post-ovulation). The Clinitest-Clinitek Status hCG device exhibited high-dose hook interference from hCGβcf alone, but not from hCG, hCGβ, or simulated physiological urinary concentrations of combined hCG, hCGβcf and hCGβ expected during early pregnancy. The majority of our patient population had urinary hCG testing conducted during early pregnancy. The Clinitest-Clinitek Status hCG device is unlikely to exhibit false-negative urinary hCG results due to high-dose hook interference for women in early healthy pregnancy, although additional studies are necessary to determine potential risk in other patient populations. Visual interpretation of POC urinary hCG device results is an important failure mode to consider in risk analyses for erroneous urinary hCG device results. Published by Elsevier Inc.
Performance of two hearing screening protocols in NICU in Shanghai.
Xu, Zheng-Min; Cheng, Wen-Xia; Yang, Xiao-Lin
2011-10-01
To study the sensitivity and specificity of targeted neonatal hearing screening for the single-session distortion product otoacoustic emissions (DPOAE) technique and the combined DPOAE/automated auditory brain-stem response (AABR) technique. 3000 high-risk newborns were studied at Children's Hospital of Fudan University. They were required to take two different screening procedures separately. The first procedure consisted of DPOAE alone and the second consisted of DPOAE combined with the AABR. Based upon the etiology in high-risk babies, they were divided into four groups. In group I there were 670 very-low-birth-weight (VLBW) newborns (1340 ears), and in group II there were 890 preterm babies (1780 ears). 850 babies (1700 ears) suffered from hyperbilirubinemia in group III, whereas 790 babies (1580 ears) with asphyxia were in group IV. The babies in groups II, III, and IV came from the neonatal intensive-care unit (NICU) of our hospital. The study protocols consisted of the DPOAE alone and DPOAE combined with AABR hearing screening at an age of less than 1 month, and a diagnostic stage at the age of 2 months. With single-session DPOAE screening, the referral rate (8% of the NICU babies), the false-positive rate (4.96%) and the false-negative rate (0.8%) were higher. The different etiologies in NICU babies had significantly different referral rates (F-test, p<0.01). A 4.46% referral rate of hyperbilirubinemi babies was much lower. The combined DPOAE/AABR screening technique revealed a referral rate of 5.03%, a false-positive rate of 2% and a false-negative rate of 0.06%. The false-positive rate was well below the suggested 3% of the American Academy of Pediatric. Comparisons of the referral rate, false-positive rate and false-negative rate of two hearing screening protocols (DPOAE alone and combined DPOAE/AABR) revealed significant differences (t-test, p<0.05, p<0.01, p<0.01). 91 infants (3.03% of the NICU babies) who failed the combined DPOAE/AABR screening were confirmed on hearing impairment. Of 22 babies who passed DPOAE screening but failed the AABR screening had a severe to profound hearing loss based on classic ABR. These patients (24% of the NICU babies with hearing losses) with hyperbilirubinemia and asphyxia problems at newborn stage were diagnosed as auditory neuropathy based on evaluations of DPOAE screening passed, abnormal ABR and absent middle-ear muscle reflexes (MMR). Our study demonstrates the use of a combination of DPOAE and AABR testing ensures high sensitivity and acceptable specificity, and predict the AN profile in NICU babies. Our efforts identified 22 NICU babies with auditory neuropathy who hopefully will benefit from early remediation of their hearing deficit. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Bachrach, D G; Bendoly, E; Podsakoff, P M
2001-12-01
The purpose of this study was to examine the possibility that feedback regarding team performance may influence team members' reports of organizational citizenship behaviors. Ninety-five teams of business students (N = 412) participated in a labor-scheduling simulation over a local area network. Teams were provided with false negative, false positive, or neutral feedback regarding their performance. Results support the hypothesis that the perception of 2 forms of organizational citizenship behavior (helping behavior and civic virtue) in work groups may, in part. be a function of the nature of the performance feedback that group members receive. However, negative feedback appears to play a more critical role than positive feedback in this attributional process. Possible reasons for these findings, as well as their implications, are discussed.
Bruno, Thiers; Abrahão, Julia
2012-01-01
This study examines the actions taken by operators aimed at preventing and combating information security incidents at a banking organization. The work utilizes the theoretical framework of ergonomics and cognitive psychology. The method is workplace ergonomic analysis. Its focus is directed towards examining the cognitive dimension of the work environment with special attention to the occurrence of correlations between variability in incident frequency and the results of sign detection actions. It categorizes 45,142 operator decisions according to the theory of signal detection (Sternberg, 2000). It analyzes the correlation between incident proportions (indirectly associated with the cognitive efforts demanded from the operator) and operator decisions. The study demonstrated the existence of a positive correlation between incident proportions and false positive decisions (false alarms). However, this correlation could not be observed in relation to decisions of the false-negative type (incorrect rejection).
Improving Universal Suicide Prevention Screening in Primary Care by Reducing False Negatives
2016-09-01
AWARD NUMBER: W81XWH-14-1-0272 TITLE: Improving universal suicide prevention screening in primary care by reducing false negatives PRINCIPAL...COVERED 9/1/2015-8/31/2016 4. TITLE AND SUBTITLE Improving universal suicide prevention screening in primary care by 5a. CONTRACT NUMBER reducing...proposed project is to develop a shortened version of the Suicide Cognitions Scale (SCS) and to evaluate its efficacy as a universal suicide prevention
Porter, Stephen; ten Brinke, Leanne; Riley, Sean N; Baker, Alysha
2014-01-01
We examined the relation between emotion and susceptibility to misinformation using a novel paradigm, the ambiguous stimuli affective priming (ASAP) paradigm. Participants (N = 88) viewed ambiguous neutral images primed either at encoding or retrieval to be interpreted as either highly positive or negative (or neutral/not primed). After viewing the images, they either were asked misleading or non-leading questions. Following a delay, memory accuracy for the original images was assessed. Results indicated that any emotional priming at encoding led to a higher susceptibility to misinformation relative to priming at recall. In particular, inducing a negative interpretation of the image at encoding led to an increased susceptibility of false memories for major misinformation (an entire object not actually present in the scene). In contrast, this pattern was reversed when priming was used at recall; a negative reinterpretation of the image decreased memory distortion relative to unprimed images. These findings suggest that, with precise experimental control, the experience of emotion at event encoding, in particular, is implicated in false memory susceptibility.
Gerstl, Sibylle; Dunkley, Sophie; Mukhtar, Ahmed; De Smet, Martin; Baker, Samuel; Maikere, Jacob
2010-01-21
Most malaria rapid diagnostic tests (RDTs) use HRP2 detection, including Paracheck-Pf(R), but their utility is limited by persistent false positivity after treatment. PLDH-based tests become negative more quickly, but sensitivity has been reported below the recommended standard of 90%. A new pLDH test, CareStart three-line P.f/PAN-pLDH, claims better sensitivity with continued rapid conversion to negative. The study aims were to 1) compare sensitivity and specificity of CareStart to Paracheck-Pf(R) to diagnose falciparum malaria in children under five years of age, 2) assess how quickly false-positive CareStart tests become negative and 3) evaluate ease of use and inter-reader agreement of both tests. Participants were included if they were aged between two and 59 months, presenting to a Médecins Sans Frontières community health centre in eastern Sierra Leone with suspected malaria defined as fever (axillary temperature > 37.5 degrees C) and/or history of fever in the previous 72 hours and no signs of severe disease. The same capillary blood was used for the RDTs and the blood slide, the latter used as the gold standard reference. All positive participants were treated with supervised artesunate and amodiaquine treatment for three days. Participants with a persistent false-positive CareStart, but a negative blood slide on Day 2, were followed with repeated CareStart and blood slide tests every seven days until CareStart became negative or a maximum of 28 days. Sensitivity of CareStart was 99.4% (CI 96.8-100.0, 168/169) and of Paracheck-Pf(R), 98.8% (95% CI 95.8-99.8, 167/169). Specificity of CareStart was 96.0% (CI 91.9-98.4, 167/174) and of Paracheck-Pf(R), 74.7% (CI 67.6-81.0, 130/174) (p < 0.001). Neither test showed any change in sensitivity with decreasing parasitaemia. Of the 155 eligible follow-up CareStart participants, 63.9% (99/155) had a false-positive test on day 2, 21.3% (33/155) on day 7, 5.8% (9/155) on day 14, 1.9% (3/155) on day 21 and 0.6% (1/155) on day 28. The median time for test negativity was seven days. CareStart was as easy to use and interpret as Paracheck-Pf(R) with excellent inter-reader agreement. Both RDTs were highly sensitive, met WHO standards for the detection of falciparum malaria monoinfections where parasitaemia was >100 parasites/mul and were easy to use. CareStart persistent false positivity decreased quickly after successful anti-malarial treatment, making it a good choice for a RDT for a hyperendemic falciparum malaria area.
Computer-aided diagnosis of contrast-enhanced spectral mammography: A feasibility study.
Patel, Bhavika K; Ranjbar, Sara; Wu, Teresa; Pockaj, Barbara A; Li, Jing; Zhang, Nan; Lobbes, Mark; Zhang, Bin; Mitchell, J Ross
2018-01-01
To evaluate whether the use of a computer-aided diagnosis-contrast-enhanced spectral mammography (CAD-CESM) tool can further increase the diagnostic performance of CESM compared with that of experienced radiologists. This IRB-approved retrospective study analyzed 50 lesions described on CESM from August 2014 to December 2015. Histopathologic analyses, used as the criterion standard, revealed 24 benign and 26 malignant lesions. An expert breast radiologist manually outlined lesion boundaries on the different views. A set of morphologic and textural features were then extracted from the low-energy and recombined images. Machine-learning algorithms with feature selection were used along with statistical analysis to reduce, select, and combine features. Selected features were then used to construct a predictive model using a support vector machine (SVM) classification method in a leave-one-out-cross-validation approach. The classification performance was compared against the diagnostic predictions of 2 breast radiologists with access to the same CESM cases. Based on the SVM classification, CAD-CESM correctly identified 45 of 50 lesions in the cohort, resulting in an overall accuracy of 90%. The detection rate for the malignant group was 88% (3 false-negative cases) and 92% for the benign group (2 false-positive cases). Compared with the model, radiologist 1 had an overall accuracy of 78% and a detection rate of 92% (2 false-negative cases) for the malignant group and 62% (10 false-positive cases) for the benign group. Radiologist 2 had an overall accuracy of 86% and a detection rate of 100% for the malignant group and 71% (8 false-positive cases) for the benign group. The results of our feasibility study suggest that a CAD-CESM tool can provide complementary information to radiologists, mainly by reducing the number of false-positive findings. Copyright © 2017 Elsevier B.V. All rights reserved.
Evaluation of musculoskeletal sepsis with indium-111 white blood cell imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ouzounian, T.J.; Thompson, L.; Grogan, T.J.
The detection of musculoskeletal sepsis, especially following joint replacement, continues to be a challenging problem. Often, even with invasive diagnostic evaluation, the diagnosis of infection remains uncertain. This is a report on the first 55 Indium-111 white blood cell (WBC) images performed in 39 patients for the evaluation of musculoskeletal sepsis. There were 40 negative and 15 positive Indium-111 WBC images. These were correlated with operative culture and tissue pathology, aspiration culture, and clinical findings. Thirty-eight images were performed for the evaluation of possible total joint sepsis (8 positive and 30 negative images); 17 for the evaluation of nonarthroplasty-related musculoskeletalmore » sepsis (7 positive and 10 negative images). Overall, there were 13 true-positive, 39 true-negative, two false-positive, and one false-negative images. Indium-111 WBC imaging is a sensitive and specific means of evaluating musculoskeletal sepsis, especially following total joint replacement.« less
47 CFR 76.981 - Negative option billing.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 4 2010-10-01 2010-10-01 false Negative option billing. 76.981 Section 76.981 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Rate Regulation § 76.981 Negative option billing. (a) A cable operator...
30 CFR 43.6 - Notice of negative finding.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Notice of negative finding. 43.6 Section 43.6... Notice of negative finding. (a) If it is determined that a special inspection is not warranted, a written notice of negative finding shall be issued as soon as possible following such determination. (b) If it is...
2014-01-01
Background The combination of single-switch access technology and scanning is the most promising means of augmentative and alternative communication for many children with severe physical disabilities. However, the physical impairment of the child and the technology’s limited ability to interpret the child’s intentions often lead to false positives and negatives (corresponding to accidental and missed selections, respectively) occurring at rates that frustrate the user and preclude functional communication. Multiple psychophysiological studies have associated cardiac deceleration and increased phasic electrodermal activity with self-realization of errors among able-bodied individuals. Thus, physiological measurements have potential utility at enhancing single-switch access, provided that such prototypical autonomic responses exist in persons with profound disabilities. Methods The present case series investigated the autonomic responses of three pediatric single-switch users with severe spastic quadriplegic cerebral palsy, in the context of a single-switch letter matching activity. Each participant exhibited distinct autonomic responses to activity engagement. Results Our analysis confirmed the presence of the autonomic response pattern of cardiac deceleration and increased phasic electrodermal activity following true positives, false positives and false negatives errors, but not subsequent to true negative outcomes. Conclusions These findings suggest that there may be merit in complementing single-switch input with autonomic measurements to improve augmentative and alternative communications for pediatric access technology users. PMID:24607065
Leung, Brian; Chau, Tom
2014-03-08
The combination of single-switch access technology and scanning is the most promising means of augmentative and alternative communication for many children with severe physical disabilities. However, the physical impairment of the child and the technology's limited ability to interpret the child's intentions often lead to false positives and negatives (corresponding to accidental and missed selections, respectively) occurring at rates that frustrate the user and preclude functional communication. Multiple psychophysiological studies have associated cardiac deceleration and increased phasic electrodermal activity with self-realization of errors among able-bodied individuals. Thus, physiological measurements have potential utility at enhancing single-switch access, provided that such prototypical autonomic responses exist in persons with profound disabilities. The present case series investigated the autonomic responses of three pediatric single-switch users with severe spastic quadriplegic cerebral palsy, in the context of a single-switch letter matching activity. Each participant exhibited distinct autonomic responses to activity engagement. Our analysis confirmed the presence of the autonomic response pattern of cardiac deceleration and increased phasic electrodermal activity following true positives, false positives and false negatives errors, but not subsequent to true negative outcomes. These findings suggest that there may be merit in complementing single-switch input with autonomic measurements to improve augmentative and alternative communications for pediatric access technology users.
Evaluation of recombinant proteins of Burkholderia mallei for serodiagnosis of glanders.
Pal, Vijai; Kumar, Subodh; Malik, Praveen; Rai, Ganga Prasad
2012-08-01
Glanders is a contagious disease caused by the Gram-negative bacillus Burkholderia mallei. The number of equine glanders outbreaks has increased steadily during the last decade. The disease must be reported to the Office International des Epizooties, Paris, France. Glanders serodiagnosis is hampered by the considerable number of false positives and negatives of the internationally prescribed tests. The major problem leading to the low sensitivity and specificity of the complement fixation test (CFT) and enzyme-linked immunosorbent assay (ELISA) has been linked to the test antigens currently used, i.e., crude preparations of whole cells. False-positive results obtained from other diagnostic tests utilizing crude antigens lead to financial losses to animal owners, and false-negative results can turn a risk into a possible threat. In this study, we report on the identification of diagnostic targets using bioinformatics tools for serodiagnosis of glanders. The identified gene sequences were cloned and expressed as recombinant proteins. The purified recombinant proteins of B. mallei were used in an indirect ELISA format for serodiagnosis of glanders. Two recombinant proteins, 0375H and 0375TH, exhibited 100% sensitivity and specificity for glanders diagnosis. The proteins also did not cross-react with sera from patients with the closely related disease melioidosis. The results of this investigation highlight the potential of recombinant 0375H and 0375TH proteins in specific and sensitive diagnosis of glanders.
Evaluation of Recombinant Proteins of Burkholderia mallei for Serodiagnosis of Glanders
Kumar, Subodh; Malik, Praveen
2012-01-01
Glanders is a contagious disease caused by the Gram-negative bacillus Burkholderia mallei. The number of equine glanders outbreaks has increased steadily during the last decade. The disease must be reported to the Office International des Epizooties, Paris, France. Glanders serodiagnosis is hampered by the considerable number of false positives and negatives of the internationally prescribed tests. The major problem leading to the low sensitivity and specificity of the complement fixation test (CFT) and enzyme-linked immunosorbent assay (ELISA) has been linked to the test antigens currently used, i.e., crude preparations of whole cells. False-positive results obtained from other diagnostic tests utilizing crude antigens lead to financial losses to animal owners, and false-negative results can turn a risk into a possible threat. In this study, we report on the identification of diagnostic targets using bioinformatics tools for serodiagnosis of glanders. The identified gene sequences were cloned and expressed as recombinant proteins. The purified recombinant proteins of B. mallei were used in an indirect ELISA format for serodiagnosis of glanders. Two recombinant proteins, 0375H and 0375TH, exhibited 100% sensitivity and specificity for glanders diagnosis. The proteins also did not cross-react with sera from patients with the closely related disease melioidosis. The results of this investigation highlight the potential of recombinant 0375H and 0375TH proteins in specific and sensitive diagnosis of glanders. PMID:22695165
Experimental investigation of false positive errors in auditory species occurrence surveys
Miller, David A.W.; Weir, Linda A.; McClintock, Brett T.; Grant, Evan H. Campbell; Bailey, Larissa L.; Simons, Theodore R.
2012-01-01
False positive errors are a significant component of many ecological data sets, which in combination with false negative errors, can lead to severe biases in conclusions about ecological systems. We present results of a field experiment where observers recorded observations for known combinations of electronically broadcast calling anurans under conditions mimicking field surveys to determine species occurrence. Our objectives were to characterize false positive error probabilities for auditory methods based on a large number of observers, to determine if targeted instruction could be used to reduce false positive error rates, and to establish useful predictors of among-observer and among-species differences in error rates. We recruited 31 observers, ranging in abilities from novice to expert, that recorded detections for 12 species during 180 calling trials (66,960 total observations). All observers made multiple false positive errors and on average 8.1% of recorded detections in the experiment were false positive errors. Additional instruction had only minor effects on error rates. After instruction, false positive error probabilities decreased by 16% for treatment individuals compared to controls with broad confidence interval overlap of 0 (95% CI: -46 to 30%). This coincided with an increase in false negative errors due to the treatment (26%; -3 to 61%). Differences among observers in false positive and in false negative error rates were best predicted by scores from an online test and a self-assessment of observer ability completed prior to the field experiment. In contrast, years of experience conducting call surveys was a weak predictor of error rates. False positive errors were also more common for species that were played more frequently, but were not related to the dominant spectral frequency of the call. Our results corroborate other work that demonstrates false positives are a significant component of species occurrence data collected by auditory methods. Instructing observers to only report detections they are completely certain are correct is not sufficient to eliminate errors. As a result, analytical methods that account for false positive errors will be needed, and independent testing of observer ability is a useful predictor for among-observer variation in observation error rates.
Whiley, Harriet
2016-12-24
Legionella is an opportunistic pathogen of public health significance. One of the main sources of Legionella is potable water systems. As a consequence of aging populations there is an increasing demographic considered at high risk for Legionellosis and, as such, a review of the guidelines is required. Worldwide, Legionella has been detected from many potable water sources, suggesting it is ubiquitous in this environment. Previous studies have identified the limitations of the current standard method for Legionella detection and the high possibility of it returning both false negative and false positive results. There is also huge variability in Legionella test results for the same water sample when conducted at different laboratories. However, many guidelines still recommend the testing of water systems. This commentary argues for the removal of routine Legionella monitoring from all water distribution guidelines. This procedure is financially consuming and false negatives may result in managers being over-confident with a system or a control mechanism. Instead, the presence of the pathogen should be assumed and focus spent on managing appropriate control measures and protecting high-risk population groups.
Whiley, Harriet
2016-01-01
Legionella is an opportunistic pathogen of public health significance. One of the main sources of Legionella is potable water systems. As a consequence of aging populations there is an increasing demographic considered at high risk for Legionellosis and, as such, a review of the guidelines is required. Worldwide, Legionella has been detected from many potable water sources, suggesting it is ubiquitous in this environment. Previous studies have identified the limitations of the current standard method for Legionella detection and the high possibility of it returning both false negative and false positive results. There is also huge variability in Legionella test results for the same water sample when conducted at different laboratories. However, many guidelines still recommend the testing of water systems. This commentary argues for the removal of routine Legionella monitoring from all water distribution guidelines. This procedure is financially consuming and false negatives may result in managers being over-confident with a system or a control mechanism. Instead, the presence of the pathogen should be assumed and focus spent on managing appropriate control measures and protecting high-risk population groups. PMID:28029126
Cytokines in pleural liquid for diagnosis of tuberculous pleurisy.
Yamada, Y; Nakamura, A; Hosoda, M; Kato, T; Asano, T; Tonegawa, K; Itoh, M
2001-07-01
An elevated level of adenosine deaminase (ADA) in pleural liquid has been considered as a supplemental diagnostic marker for tuberculous pleurisy. However, this is complicated by false-positives and -negatives. Recently, it has been revealed that various cytokines are intimately involved in the pathognomonic physiology of tuberculosis. In this study, interleukin-8 (IL-8), tumour necrosis factor alpha (TNFalpha) and interferon gamma (IFNgamma) were compared with ADA in pleural liquid of patients with inflammatory (21 cases), malignant (28 cases) and tuberculous (21 cases) disease. The pleural ADA, IL-8, TNFalpha and IFNgamma levels in the tuberculous group were higher than in the other three groups. Analysis of receiver operating characteristic (ROC) curves, to evaluate the utility of the various parameters, demonstrates values for the area under the curve (AUC) of 0.770, 0.875, 0.892 and 0.987, respectively for IL-8, TNFalpha, ADA and IFNgamma. No false-positives were encountered with IFNgamma and only one case with a small volume of pleural liquid was a false-negative. This indicates that IFNgamma is a very reliable marker of tuberculous pleurisy.
... including physical and emotional problems. False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...
Accuracy of ultrasound for the prediction of placenta accreta.
Bowman, Zachary S; Eller, Alexandra G; Kennedy, Anne M; Richards, Douglas S; Winter, Thomas C; Woodward, Paula J; Silver, Robert M
2014-08-01
Ultrasound has been reported to be greater than 90% sensitive for the diagnosis of accreta. Prior studies may be subject to bias because of single expert observers, suspicion for accreta, and knowledge of risk factors. We aimed to assess the accuracy of ultrasound for the prediction of accreta. Patients with accreta at a single academic center were matched to patients with placenta previa, but no accreta, by year of delivery. Ultrasound studies with views of the placenta were collected, deidentified, blinded to clinical history, and placed in random sequence. Six investigators prospectively interpreted each study for the presence of accreta and findings reported to be associated with its diagnosis. Sensitivity, specificity, positive predictive, negative predictive value, and accuracy were calculated. Characteristics of accurate findings were compared using univariate and multivariate analyses. Six investigators examined 229 ultrasound studies from 55 patients with accreta and 56 controls for 1374 independent observations. 1205/1374 (87.7% overall, 90% controls, 84.9% cases) studies were given a diagnosis. There were 371 (27.0%) true positives; 81 (5.9%) false positives; 533 (38.8%) true negatives, 220 (16.0%) false negatives, and 169 (12.3%) with uncertain diagnosis. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 53.5%, 88.0%, 82.1%, 64.8%, and 64.8%, respectively. In multivariate analysis, true positives were more likely to have placental lacunae (odds ratio [OR], 1.5; 95% confidence interval [CI], 1.4-1.6), loss of retroplacental clear space (OR, 2.4; 95% CI, 1.1-4.9), or abnormalities on color Doppler (OR, 2.1; 95% CI, 1.8-2.4). Ultrasound for the prediction of placenta accreta may not be as sensitive as previously described. Copyright © 2014 Mosby, Inc. All rights reserved.
Cai, Jing; Yan, Beizhan; Kinney, Patrick L.; Perzanowski, Matthew S.; Jung, Kyung-Hwa; Li, Tiantian; Xiu, Guangli; Zhang, Danian; Olivo, Cosette; Ross, James; Miller, Rachel L.; Chillrud, Steven N.
2014-01-01
Exposure to ambient black carbon (BC) is associated with adverse health effects. Black carbon levels display large spatial and temporal variability in many settings, such as cities and rural households where fossil fuel and biomass, respectively, are commonly burned for transportation, heat and cooking. This paper addresses the optimization of the miniaturized personal BC monitor, the microAeth® for use in epidemiology studies. To address false positive and negative peaks in real time BC concentrations resulting from changes in temperature and humidity, an inlet with a diffusion drier was developed. In addition, we developed data cleaning algorithms to address occasional false positive and negative fluctuations in BC readings related to physical vibration, due in part to both dirt accumulations in the optical inserts and degraded components. These methods were successfully used to process real-time BC data generated from a cohort of 9-10 year old children (N= 54) in NYC, who wore 1 or 2 microAeth units for six 24hr time periods. Two hour and daily BC averages after data cleaning were consistent with averaged raw data (slopes near 1 with R =0.99, p<0.001; R= 0.95, p<0.001, respectively), strongly suggesting that the false positive and negative excursions balance each other out when averaged for at least 2 hrs. Data cleaning of identified suspect events allows more confidence in the interpretation of the real-time personal monitoring data generated in environmental exposure studies, with mean percent difference <10% for 19 duplicate deployments. PMID:25558122
Ability of Ultrasonography in Detection of Different Extremity Bone Fractures; a Case Series Study
Bozorgi, Farzad; Shayesteh Azar, Massoud; Montazer, Seyed Hossein; Chabra, Aroona; Heidari, Seyed Farshad; Khalilian, Alireza
2017-01-01
Introduction: Despite radiography being the gold standard in evaluation of orthopedic injuries, using bedside ultrasonography has several potential supremacies such as avoiding exposure to ionizing radiation, availability in pre-hospital settings, being extensively accessible, and ability to be used on the bedside. The aim of the present study is to evaluate the diagnostic accuracy of ultrasonography in detection of extremity bone fractures. Methods: This study is a case series study, which was prospectively conducted on multiple blunt trauma patients, who were 18 years old or older, had stable hemodynamic, Glasgow coma scale 15, and signs or symptoms of a possible extremity bone fracture. After initial assessment, ultrasonography of suspected bones was performed by a trained emergency medicine resident and prevalence of true positive and false negative findings were calculated compared to plain radiology. Results: 108 patients with the mean age of 44.6 ± 20.4 years were studied (67.6% male). Analysis was done on 158 sites of fracture, which were confirmed with plain radiography. 91 (57.6%) cases were suspected to have upper extremity fracture(s) and 67 (42.4%) to have lower ones. The most frequent site of injuries were forearm (36.7%) in upper limbs and leg (27.8%) in lower limbs. Prevalence of true positive and false negative cases for fractures detected by ultrasonography were 59 (64.8%) and 32 (35.52%) for upper and 49 (73.1%) and 18 (26.9%) for lower extremities, respectively. In addition, prevalence of true positive and false negative detected cases for intra-articular fractures were 24 (48%) and 26 (52%), respectively. Conclusion The present study shows the moderate sensitivity (68.3%) of ultrasonography in detection of different extremity bone fractures. Ultrasonography showed the best sensitivity in detection of femur (100%) and humerus (76.2%) fractures, respectively. It had low sensitivity in detection of in intra-articular fractures. PMID:28286822
Ability of Ultrasonography in Detection of Different Extremity Bone Fractures; a Case Series Study.
Bozorgi, Farzad; Shayesteh Azar, Massoud; Montazer, Seyed Hossein; Chabra, Aroona; Heidari, Seyed Farshad; Khalilian, Alireza
2017-01-01
Despite radiography being the gold standard in evaluation of orthopedic injuries, using bedside ultrasonography has several potential supremacies such as avoiding exposure to ionizing radiation, availability in pre-hospital settings, being extensively accessible, and ability to be used on the bedside. The aim of the present study is to evaluate the diagnostic accuracy of ultrasonography in detection of extremity bone fractures. This study is a case series study, which was prospectively conducted on multiple blunt trauma patients, who were 18 years old or older, had stable hemodynamic, Glasgow coma scale 15, and signs or symptoms of a possible extremity bone fracture. After initial assessment, ultrasonography of suspected bones was performed by a trained emergency medicine resident and prevalence of true positive and false negative findings were calculated compared to plain radiology. 108 patients with the mean age of 44.6 ± 20.4 years were studied (67.6% male). Analysis was done on 158 sites of fracture, which were confirmed with plain radiography. 91 (57.6%) cases were suspected to have upper extremity fracture(s) and 67 (42.4%) to have lower ones. The most frequent site of injuries were forearm (36.7%) in upper limbs and leg (27.8%) in lower limbs. Prevalence of true positive and false negative cases for fractures detected by ultrasonography were 59 (64.8%) and 32 (35.52%) for upper and 49 (73.1%) and 18 (26.9%) for lower extremities, respectively. In addition, prevalence of true positive and false negative detected cases for intra-articular fractures were 24 (48%) and 26 (52%), respectively. The present study shows the moderate sensitivity (68.3%) of ultrasonography in detection of different extremity bone fractures. Ultrasonography showed the best sensitivity in detection of femur (100%) and humerus (76.2%) fractures, respectively. It had low sensitivity in detection of in intra-articular fractures.
Quan, May Lynn; Wells, Bryan J; McCready, David; Wright, Frances C; Fraser, Novlette; Gagliardi, Anna R
2010-02-01
Sentinel lymph node biopsy (SNLB) has been adopted as the standard method of axillary staging for women with clinically node-negative early-stage breast cancer. The false negative rate as a quality indicator is impractical given the need for a completion axillary dissection to calculate. The objective of this study was to develop practical quality indicators for SLNB using an expert consensus method and to determine if they were feasible to measure. We used a modified Delphi consensus process to develop quality indicators for SLNB. A multidisciplinary expert panel reviewed potential indicators extracted from the medical literature to select quality indicators that were relevant and measurable. Feasibility was determined by abstracting the quality indicator variables from a retrospective chart review. The expert panel prioritized 11 quality indicators as benchmarks for assessing the quality of surgical care in SNLB. Nine of the indicators were measurable at the chart or institutional level. A systematic evidence- and consensus-based approach was used to develop measurable quality indicators that could be used by practicing surgeons and administrators to evaluate performance of SLNB in breast cancer.
Wang, Li-jun; Lu, Xin-xin; Wu, Wei; Sui, Wen-jun; Zhang, Gui
2014-01-01
In order to evaluate a rapid matrix-assisted laser desorption ionization-time of flight mass spectrometry (MAIDI-TOF MS) assay in screening vancomycin-resistant Enterococcus faecium, a total of 150 E. faecium clinical strains were studied, including 60 vancomycin-resistant E. faecium (VREF) isolates and 90 vancomycin-susceptible (VSEF) strains. Vancomycin resistance genes were detected by sequencing. E. faecium were identified by MALDI-TOF MS. A genetic algorithm model with ClinProTools software was generated using spectra of 30 VREF isolates and 30 VSEF isolates. Using this model, 90 test isolates were discriminated between VREF and VSEF. The results showed that all sixty VREF isolates carried the vanA gene. The performance of VREF detection by the genetic algorithm model of MALDI-TOF MS compared to the sequencing method was sensitivity = 80%, specificity = 90%, false positive rate =10%, false negative rate =10%, positive predictive value = 80%, negative predictive value= 90%. MALDI-TOF MS can be used as a screening test for discrimination between vanA-positive E. faecium and vanA-negative E. faecium.
The diagnostic significance of lactate dehydrogenase isoenzymes in urinary cytology.
Nishikawa, A.; Tanaka, T.; Takeuchi, T.; Fujihiro, S.; Mori, H.
1991-01-01
Lactate dehydrogenase (LDH) isoenzyme distribution was examined in 106 urine samples being tested cytologically for evidence of bladder cancer; the samples were selected to have less than 20 leucocytes and erythrocytes per high power field and the LDH pattern determined by electrophoresis. The Papanicolaou stained-smears showed 68 negative, 17 suspicious and 21 positive. The LDH M-fraction of the urinary supernatant in cytologically positive cases was significantly greater than in negative cases, although the latter included a few false negative samples. Some of the false negatives gave positive results for the LDH M-fraction; these results suggest that the determination of LDH isoenzymes in the urine is useful in diagnosing urinary tract cancers, including early stage, and for follow-up of patients with bladder cancers after surgical resection. PMID:2039708
Effects of hydrocortisone on false memory recognition in healthy men and women.
Duesenberg, Moritz; Weber, Juliane; Schaeuffele, Carmen; Fleischer, Juliane; Hellmann-Regen, Julian; Roepke, Stefan; Moritz, Steffen; Otte, Christian; Wingenfeld, Katja
2016-12-01
Most of the studies focusing on the effect of stress on false memories by using psychosocial and physiological stressors yielded diverse results. In the present study, we systematically tested the effect of exogenous hydrocortisone using a false memory paradigm. In this placebo-controlled study, 37 healthy men and 38 healthy women (mean age 24.59 years) received either 10 mg of hydrocortisone or placebo 75 min before using the false memory, that is, Deese-Roediger-McDermott (DRM), paradigm. We used emotionally charged and neutral DRM-based word lists to look for false recognition rates in comparison to true recognition rates. Overall, we expected an increase in false memory after hydrocortisone compared to placebo. No differences between the cortisol and the placebo group were revealed for false and for true recognition performance. In general, false recognition rates were lower compared to true recognition rates. Furthermore, we found a valence effect (neutral, positive, negative, disgust word stimuli), indicating higher rates of true and false recognition for emotional compared to neutral words. We further found an interaction effect between sex and recognition. Post hoc t tests showed that for true recognition women showed a significantly better memory performance than men, independent of treatment. This study does not support the hypothesis that cortisol decreases the ability to distinguish between old versus novel words in young healthy individuals. However, sex and emotional valence of word stimuli appear to be important moderators. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...
Roberts, David W; Schultz, Terry W; Api, Anne Marie
2016-10-01
The Local Lymph Node Assay (LLNA) is the gold standard regulatory toxicology test for skin sensitisation along with the guinea pig maximisation test (GPMT). Compared with the GPMT, LLNA uses fewer animals, it is quantitative, and it gives a numerical prediction of potency. However several concerns have been raised with this assay, mainly related to false positives and false negatives. Over the years, many authors, including the developers of the assay, have presented cases where there have been discrepancies between the GMPT and LLNA results. Several theories have been put forward for these discrepancies, the main one being the "over-sensitivity" of the GPMT. This paper analyses the data from a systematic study, published in three papers from 2008 to 2011, covering several classes of chemicals, in particular unsaturated fatty acids, sugar surfactants and ethoxylated alcohols, with many cases of chemicals testing positive in the LLNA being negative in the GPMT. Based on consideration of reaction chemistry and structural alerts, it is concluded that these discrepancies are not LLNA false positives, but can be rationalised in terms of the different protocols of the assays. Copyright © 2016 Elsevier Inc. All rights reserved.
Automatic mouse ultrasound detector (A-MUD): A new tool for processing rodent vocalizations.
Zala, Sarah M; Reitschmidt, Doris; Noll, Anton; Balazs, Peter; Penn, Dustin J
2017-01-01
House mice (Mus musculus) emit complex ultrasonic vocalizations (USVs) during social and sexual interactions, which have features similar to bird song (i.e., they are composed of several different types of syllables, uttered in succession over time to form a pattern of sequences). Manually processing complex vocalization data is time-consuming and potentially subjective, and therefore, we developed an algorithm that automatically detects mouse ultrasonic vocalizations (Automatic Mouse Ultrasound Detector or A-MUD). A-MUD is a script that runs on STx acoustic software (S_TOOLS-STx version 4.2.2), which is free for scientific use. This algorithm improved the efficiency of processing USV files, as it was 4-12 times faster than manual segmentation, depending upon the size of the file. We evaluated A-MUD error rates using manually segmented sound files as a 'gold standard' reference, and compared them to a commercially available program. A-MUD had lower error rates than the commercial software, as it detected significantly more correct positives, and fewer false positives and false negatives. The errors generated by A-MUD were mainly false negatives, rather than false positives. This study is the first to systematically compare error rates for automatic ultrasonic vocalization detection methods, and A-MUD and subsequent versions will be made available for the scientific community.
Stress and emotional valence effects on children's versus adolescents' true and false memory.
Quas, Jodi A; Rush, Elizabeth B; Yim, Ilona S; Edelstein, Robin S; Otgaar, Henry; Smeets, Tom
2016-01-01
Despite considerable interest in understanding how stress influences memory accuracy and errors, particularly in children, methodological limitations have made it difficult to examine the effects of stress independent of the effects of the emotional valence of to-be-remembered information in developmental populations. In this study, we manipulated stress levels in 7-8- and 12-14-year-olds and then exposed them to negative, neutral, and positive word lists. Shortly afterward, we tested their recognition memory for the words and false memory for non-presented but related words. Adolescents in the high-stress condition were more accurate than those in the low-stress condition, while children's accuracy did not differ across stress conditions. Also, among adolescents, accuracy and errors were higher for the negative than positive words, while in children, word valence was unrelated to accuracy. Finally, increases in children's and adolescents' cortisol responses, especially in the high-stress condition, were related to greater accuracy but not false memories and only for positive emotional words. Findings suggest that stress at encoding, as well as the emotional content of to-be-remembered information, may influence memory in different ways across development, highlighting the need for greater complexity in existing models of true and false memory formation.
False positives complicate ancient pathogen identifications using high-throughput shotgun sequencing
2014-01-01
Background Identification of historic pathogens is challenging since false positives and negatives are a serious risk. Environmental non-pathogenic contaminants are ubiquitous. Furthermore, public genetic databases contain limited information regarding these species. High-throughput sequencing may help reliably detect and identify historic pathogens. Results We shotgun-sequenced 8 16th-century Mixtec individuals from the site of Teposcolula Yucundaa (Oaxaca, Mexico) who are reported to have died from the huey cocoliztli (‘Great Pestilence’ in Nahautl), an unknown disease that decimated native Mexican populations during the Spanish colonial period, in order to identify the pathogen. Comparison of these sequences with those deriving from the surrounding soil and from 4 precontact individuals from the site found a wide variety of contaminant organisms that confounded analyses. Without the comparative sequence data from the precontact individuals and soil, false positives for Yersinia pestis and rickettsiosis could have been reported. Conclusions False positives and negatives remain problematic in ancient DNA analyses despite the application of high-throughput sequencing. Our results suggest that several studies claiming the discovery of ancient pathogens may need further verification. Additionally, true single molecule sequencing’s short read lengths, inability to sequence through DNA lesions, and limited ancient-DNA-specific technical development hinder its application to palaeopathology. PMID:24568097
Evaluation of the on-site immunoassay drug-screening device Triage-TOX in routine forensic autopsy.
Tominaga, Mariko; Michiue, Tomomi; Maeda, Hitoshi
2015-11-01
Instrumental identification of drugs with quantification is essential in forensic toxicology, while on-site immunoassay urinalysis drug-screening devices conveniently provide preliminary information when adequately used. However, suitable or sufficient urine specimens are not always available. The present study evaluated the efficacy of a new on-site immunoassay drug-screening device Triage-TOX (Alere Inc., San Diego, CA, USA), which has recently been developed to provide objective data on the one-step automated processor, using 51 urine and 19 pericardial fluid samples from 66 forensic autopsy cases, compared with Triage-Drug of Abuse (DOA) and Monitect-9. For benzodiazepines, the positive predictive value and specificity of Triage-TOX were higher than those of Triage-DOA; however, sensitivity was higher with Monitect-9, despite frequent false-positives. The results for the other drugs with the three devices also included a few false-negatives and false-positives. These observations indicate the applicability of Triage-TOX in preliminary drug screening using urine or alternative materials in routine forensic autopsy, when a possible false-negative is considered, especially for benzodiazepines, providing objective information; however, the combined use of another device such as Monitect-9 can help minimize misinterpretation prior to instrumental analysis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
7 CFR 996.11 - Negative aflatoxin content.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 8 2013-01-01 2013-01-01 false Negative aflatoxin content. 996.11 Section 996.11 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... aflatoxin content. Negative aflatoxin content means 15 parts per billion (ppb) or less for peanuts that have...
7 CFR 996.11 - Negative aflatoxin content.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 8 2014-01-01 2014-01-01 false Negative aflatoxin content. 996.11 Section 996.11 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (MARKETING... aflatoxin content. Negative aflatoxin content means 15 parts per billion (ppb) or less for peanuts that have...
7 CFR 996.11 - Negative aflatoxin content.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 8 2012-01-01 2012-01-01 false Negative aflatoxin content. 996.11 Section 996.11 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing... aflatoxin content. Negative aflatoxin content means 15 parts per billion (ppb) or less for peanuts that have...
40 CFR 62.5375 - Identification of plan-negative declaration.
Code of Federal Regulations, 2010 CFR
2010-07-01
...—negative declaration. The State Department of Environmental Quality Engineering submitted on July 31, 1979... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Identification of plan-negative declaration. 62.5375 Section 62.5375 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...
40 CFR 57.816 - Effect of negative recommendation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Effect of negative recommendation. 57.816 Section 57.816 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Reduction Technology § 57.816 Effect of negative recommendation. No waiver of the interim requirement for...
Performance of acidified 14C-urea capsule breath test during pantoprazole and ranitidine treatment.
Oztürk, Emel; Yeşilova, Zeki; Ilgan, Seyfettin; Ozgüven, Mehmet; Dağalp, Kemal
2009-07-01
Urea breath test (UBT) results could be false negative in patients taking antisecretory drugs. This effect would be prevented by citric acid administration during UBT. We prospectively investigated whether acidified 14C-urea capsule prevents false negative UBT results in patients taking antisecretory drugs and show interference with the duration of medications. Sixty Helicobacter pylori positive patients were included. Pantoprazole (40 mg/day) was given to 27 patients for 28 days and ranitidine (300 mg. o.d.) to 33 patients for 60 days. Urea breath tests were repeated on days 14 and 28 in both groups and on day 60 in the ranitidine group. The baseline mean breath counts of two groups did not show any significant difference. Pantoprazole led to a significant decrease in mean breath counts on day 14 (P < 0.005). Six of 27 and 3 of 25 patients taking pantoprazole developed negative or equivocal UBT results on days 14 and 28, respectively. Two of 32, 2 of 32 and 3 of 21 patients taking ranitidine developed negative or equivocal UBT results on days 14, 28 and 60, respectively. The use of acidified 14C-urea capsule did not prevent false negative UBT results in patients taking pantoprazole and ranitidine, and the duration of medication does not affect the test results.
... rule out a possible false-negative result. Normal Results A negative or nonreactive result means that you ... meaning of your specific test results. What Abnormal Results Mean A positive FTA-ABS is often a ...
The efficacy of sentinel lymph node mapping with indocyanine green in cervical cancer.
Kim, Ju-Hyun; Kim, Dae-Yeon; Suh, Dae-Shik; Kim, Jong-Hyeok; Kim, Yong-Man; Kim, Young-Tak; Nam, Joo-Hyun
2018-03-09
Lymph node metastasis is a significant predictive factor for disease recurrence and survival in cervical cancer patients. Given the importance of lymph node metastasis, it is imperative that patients harboring metastasis are identified and can undergo appropriate treatment. Sentinel lymph node (SLN) mapping has drawn attention as a lymph node mapping technique. We evaluated the feasibility and efficacy of (SLN) mapping using indocyanine green (ICG) in cervical cancer. We performed a single-center, retrospective study of 103 surgically treated cervical cancer patients who underwent SLN mapping. After using ICG to detect SLN during surgery, we removed the SLNs followed by laparoscopic or robotic-assisted radical surgery and bilateral pelvic lymphadenectomy. Stage IB1 was the most common (61.17%). At least one SLN was detected in all cases. Eighty-eight patients (85.44%) had bilateral pelvic SLNs. The mean number of SLN per patient was 2.34. The side-specific sensitivity was 71.43%, the specificity was 100%, the negative predictive value (NPV) was 93.98%, and the false negative rate (FNR) was 28.57%. In cases of tumors smaller than 2 cm with negative lymph node metastasis on imaging, the study revealed a side-specific sensitivity of 100%, a specificity of 100%, a NPV of 100%, and a FNR of 0%. Large tumor size (≥ 4 cm), a previous history of a loop electrosurgical excision procedure (LEEP), depth of invasion (≥ 50%), the microscopic parametrial (PM) invasion, and vaginal extension were significantly associated with the false-negative detection of SLN. Moreover, the microscopic PM invasion was the only risk factor of the false-negative detection of SLN in multivariate analysis. SLN mapping with ICG in cervical cancer is feasible and has high detection rate. The sensitivity of 100% was high enough to perform SLN biopsy alone in an early stage in which the tumor is less than 2 cm, with no lymphadenopathy on image examination. However, for large or invasive tumors, we would have to be cautious about performing SLN biopsy alone. Retrospectively registered 2017-0600.
Paz-Alonso, Pedro M; Goodman, Gail S
2016-01-01
In the present study, we investigated age differences in children's eyewitness memory and suggestibility for negative and positive events that children often experience during middle childhood. We first examined 216 ratings by children aged 8-12 years of the frequency and intensity of personal negative and positive experiences (Study 1). Based on those ratings, videotapes depicting the most frequent and intense negative (an accident) and positive (a family excursion) events were developed. A new sample of 227 children aged 8-12 years was tested for recognition memory of the videotapes using the three-stage post-event misinformation procedure (Study 2). Compared with 8- to 9-year-olds, 10- to 12-year-olds exhibited less memory malleability and less compliance with false information. Age improvements in recognition accuracy were also evident for children who watched the negative event, but not for those who watched the positive event. Compliance predicted misinformation effects, particularly in regard to peripheral details. Thus, using ecologically representative emotional events, age differences in suggestibility and memory accuracy emerged, especially for negative events.Theoretical and forensic implications concerning children's eyewitness memory and suggestibility are discussed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Modified Test Protocol Improves Sensitivity of the Stereo Fly Test.
De La Cruz, Angie; Morale, Sarah E; Jost, Reed M; Kelly, Krista R; Birch, Eileen E
2016-01-01
Stereoacuity measurement is a common element of pediatric ophthalmic examinations. Although the Stereo Fly Test is routinely used to establish the presence of coarse stereopsis (3000 arcsecs), it often yields a false negative "pass" due to learned responses and non-stereoscopic cues. We developed and evaluated a modified Stereo Fly Test protocol aimed at increasing sensitivity, thus reducing false negatives. The Stereo Fly Test was administered according to manufacturer instructions to 321 children aged 3-12 years. Children with a "pass" outcome (n = 147) were re-tested wearing glasses fitted with polarizers of matching orientation for both eyes to verify that they were responding to stereoscopic cues (modified protocol). The response to the standard Stereo Fly Test was considered a false negative (pass) if the child still pinched above the plate after disparity cues were eliminated. Randot ® Preschool Stereoacuity and Butterfly Tests were used as gold standards. Sensitivity was 81% (95% CI: 0.75 - 0.86) for standard administration of the Stereo Fly Test (19% false negative "pass"). The modified protocol increased sensitivity to 90% (95% CI: 0.85 - 0.94). The modified two-step protocol is a simple and convenient way to administer the Stereo Fly Test with increased sensitivity in a clinical setting. © 2016 Board of regents of the University of Wisconsin System, American Orthoptic Journal, Volume 66, 2016, ISSN 0065-955X, E-ISSN 1553-4448.
Leppänen, J M; Niehaus, D J H; Koen, L; Du Toit, E; Schoeman, R; Emsley, R
2006-06-01
Schizophrenia is associated with a deficit in the recognition of negative emotions from facial expressions. The present study examined the universality of this finding by studying facial expression recognition in African Xhosa population. Forty-four Xhosa patients with schizophrenia and forty healthy controls were tested with a computerized task requiring rapid perceptual discrimination of matched positive (i.e. happy), negative (i.e. angry), and neutral faces. Patients were equally accurate as controls in recognizing happy faces but showed a marked impairment in recognition of angry faces. The impairment was particularly pronounced for high-intensity (open-mouth) angry faces. Patients also exhibited more false happy and angry responses to neutral faces than controls. No correlation between level of education or illness duration and emotion recognition was found but the deficit in the recognition of negative emotions was more pronounced in familial compared to non-familial cases of schizophrenia. These findings suggest that the deficit in the recognition of negative facial expressions may constitute a universal neurocognitive marker of schizophrenia.
[Pharmacovigilance center --internal medicine interactions: A useful diagnostic tool].
Rochoy, M; Gautier, S; Bordet, R; Caron, J; Launay, D; Hachulla, E; Hatron, P-Y; Lambert, M
2015-08-01
Patients hospitalized in internal medicine often have unexplained clinical symptoms for which a drug origin can be considered. The prevalence of patients hospitalized for iatrogenic is estimated between 4-22%. We wanted to evaluate the diagnostic value of the regional center of pharmacovigilance to identify or confirm an iatrogenic disease in the department of internal medicine of Lille and characterize factors associated with drug-related side effect. This is a single-center prospective diagnostic study. We included all subsequent requests from the department of internal medicine with the Nord-Pas-de-Calais regional pharmacovigilance center between 2010 and 2012. The opinion of the regional pharmacovigilance centre was held on the record of the adverse drug reaction in the national pharmacovigilance database and analyzed according to the conclusion of iatrogenic used by clinicians in internal medicine (reference diagnosis) with a follow-up to June 2013. The variables relating to the patient, medication and adverse events were analyzed by binary logistic regression. We analyzed 160 contacts: 118 concordant cases, 38 false-positives (drug-related side effect retained by the regional pharmacovigilance center only), 4 false negatives. Registration in the national pharmacovigilance database had a sensitivity of 96% (95% CI [0.92 to 0.99]), a specificity of 46% (95% CI [0.38 to 0.53]), a value positive predictive of 69% (95% CI [0.62 to 0.76]), a negative predictive value of 89% (95% CI [0.84 to 0.94]) and a negative likelihood ratio of 0.1. False-positive had chronological and semiological accountabilities questionable (adjusted RR=2.1, 95% CI [1.2 to 2.8]). In our study, the regional pharmacovigilance center confirms the clinician's suspicion of drug-related side effects and helps to exclude drug-induced with a high negative predictive value. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.
Akduman Alaşehir, Elçin; Balıkçı, Ahmet; Partal, Mualla; Çatmabacak, Gülay; Yaman, Görkem
2016-09-01
Effective diagnosis of tuberculosis is of great importance for transmission control and treatment success. The purpose of this study is to evaluate microscopic examination results of Ehrlich-Ziehl Neelsen (EZN) and Auramine-Rhodamine staining methods and automated BACTEC MGIT 960™ system and Löwenstein-Jensen (L-J) culture results of various clinical samples in the light of recent data from the world and Turkey. Specimens that were sent from various clinics to Sureyyapasa Chest Diseases and Chest Surgery Training and Research Hospital Microbiology Laboratory from January 2012 to December 2015 were evaluated retrospectively. From a total of 62456 samples; 60923 (97.5%) were pulmonary and 1533 (2.5%) were non-pulmonary samples, especially pleura. 2853 (4.6%) Acid-resistant bacilli (ARB) positivity was detected and mycobacterial culture positivity was in total 12.2%. 7076 (93%) and 535 (7%) mycobacteria other than tuberculosis (MOTT) strains were isolated. In 356 specimens the cultures were negative in despite the positive ARB results. Considering mycobacterial culture as the gold standard; the sensitivity, specificity, positive and negative predictive values of ARB microscopy were 32.8%, 99.4%, 87.5% and 91.4%, respectively. The contamination rates in total were within acceptable limits being 2.7% for L-J and 3.8% for MGIT. Analysis of our data indicated that the sensitivity of microscopy is low and it should be evaluated together with the mycobacterial culture to rule out tuberculosis infection. With the use of fluorescent staining and also L-J and MGIT broth together for routine culture since 2013; ARB false negativity rate was observed to fall to 51.7% from 74.1% compared to the years. The follow-up of data such as the sensitivity of microscopy, culture positivity, false-positivity and false-negativity rates and contamination values is of great importance in terms of assessing compliance with laboratory quality standards and contributing to the surveillance studies.
Stanzel, Susanne; Pernthaler, Birgit; Schwarz, Thomas; Bjelic-Radisic, Vesna; Kerschbaumer, Stefan; Aigner, Reingard M
2018-06-01
of the study was to demonstrate the diagnostic and prognostic value of SPECT/CT in sentinel lymph node mapping (SLNM) in patients with invasive breast cancer. 114 patients with invasive breast cancer with clinically negative lymph nodes were included in this retrospective study as they were referred for SLNM with 99m Tc-nanocolloid. Planar image acquisition was accomplished in a one-day or two-day protocol depending on the schedule of the surgical procedure. Low dose SPECT/CT was performed after the planar images. The sentinel lymph node biopsy (SLNB) was considered false negative if a primary recurrence developed within 12 months after SLNB in the axilla from which a tumor-free SLN had been removed. Between December 2009 and December 2011, 114 patients (pts.) underwent SLNM with additional SPECT/CT. Planar imaging identified in 109 pts. 139 SLNs, which were tumor-positive in 42 nodes (n = 41 pts.). SPECT/CT identified in 81 pts. 151 additional SLNs, of which 19 were tumor-positive and led to therapy change (axillary lymph node dissection) in 11 pts. (9.6 %). Of overall 61 tumor-positive SLNs (n = 52 pts.) SPECT/CT detected all, whereas planar imaging detected only 42 of 61 ( P < 0.0001). No patient had lymph node metastasis within 12 months after SLNB in the axilla from which a tumor-free SLN had been removed resulting in a false-negative rate of 0 %. The local relapse rate was 1.8 % leading to a 4-year disease-free survival rate of 90 %. Among patients with breast cancer, the use of SPECT/CT-aided SLNM correlated due to a better anatomical localization and identification of planar not visible SLNs with a higher detection rate of SLNs. This led to therapeutic consequences and an excellent false-negative and 4-year disease-free survival rate. Schattauer GmbH.
McClintock, Brett T.; Bailey, Larissa L.; Pollock, Kenneth H.; Simons, Theodore R.
2010-01-01
The recent surge in the development and application of species occurrence models has been associated with an acknowledgment among ecologists that species are detected imperfectly due to observation error. Standard models now allow unbiased estimation of occupancy probability when false negative detections occur, but this is conditional on no false positive detections and sufficient incorporation of explanatory variables for the false negative detection process. These assumptions are likely reasonable in many circumstances, but there is mounting evidence that false positive errors and detection probability heterogeneity may be much more prevalent in studies relying on auditory cues for species detection (e.g., songbird or calling amphibian surveys). We used field survey data from a simulated calling anuran system of known occupancy state to investigate the biases induced by these errors in dynamic models of species occurrence. Despite the participation of expert observers in simplified field conditions, both false positive errors and site detection probability heterogeneity were extensive for most species in the survey. We found that even low levels of false positive errors, constituting as little as 1% of all detections, can cause severe overestimation of site occupancy, colonization, and local extinction probabilities. Further, unmodeled detection probability heterogeneity induced substantial underestimation of occupancy and overestimation of colonization and local extinction probabilities. Completely spurious relationships between species occurrence and explanatory variables were also found. Such misleading inferences would likely have deleterious implications for conservation and management programs. We contend that all forms of observation error, including false positive errors and heterogeneous detection probabilities, must be incorporated into the estimation framework to facilitate reliable inferences about occupancy and its associated vital rate parameters.
Kagna, Olga; Kurash, Marina; Ghanem-Zoubi, Nesrin; Keidar, Zohar; Israel, Ora
2017-11-01
18 F-FDG PET/CT plays a significant role in the assessment of various infectious processes. Patients with suspected or known sites of infection are often referred for 18 F-FDG imaging while already receiving antibiotic treatment. The current study assessed whether antibiotic therapy affected the detectability rate of infectious processes by 18 F-FDG PET/CT. Methods: A 5-y retrospective study of all adult patients who underwent 18 F-FDG PET/CT in search of a focal source of infection was performed. The presence, duration, and appropriateness of antibiotic treatment before 18 F-FDG imaging were recorded. Diagnosis of an infectious process was based on microbiologic or pathologic data as well as on clinical and radiologic follow-up. Results: Two hundred seventeen patients underwent 243 PET/CT studies in search of a focal source of infection and were included in the study. Sixty-seven studies were excluded from further analysis because of a final noninfectious etiology or lack of further follow-up or details regarding the antibiotic treatment. The final study population included 176 18 F-FDG PET/CT studies in 153 patients (107 men, 46 women; age range, 18-86 y). One hundred nineteen studies (68%) were performed in patients receiving antibiotic therapy for a range of 1-73 d. A diagnosis of infection was made in 107 true-positive cases (61%), including 63 studies (59%) in patients receiving appropriate antibiotic therapy started before the performance of the 18 F-FDG PET/CT study. There were 52 true-negative (29%) and 17 false-positive (10%) 18 F-FDG PET/CT studies. No false-negative results were found. Conclusion: 18 F-FDG PET/CT correctly identified foci of increased uptake compatible with infection in most patients, including all patients receiving appropriate antimicrobial therapy, with no false-negative cases. On the basis of the current study results, the administration of antibiotics appears to have no clinically significant impact on the diagnostic accuracy of 18 F-FDG PET/CT performed for evaluation of known or suspected infectious processes. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Risks of Skin Cancer Screening
... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...
40 CFR 57.816 - Effect of negative recommendation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Effect of negative recommendation. 57... Reduction Technology § 57.816 Effect of negative recommendation. No waiver of the interim requirement for... or a State first takes into account the Administrator's report, findings, and recommendations as to...
Sentinel lymph node detection in patients with early cervical cancer.
Acharya, B C; Jihong, L
2009-01-01
Lymph node status is the most important independent prognostic factor in early stage cervical cancer. Intraoperative lymphatic mapping and sentinel lymph node detection have been increasingly evaluated in the treatment of a variety of solid tumors, particularly breast cancer and cutaneous melanoma. This study evaluated the feasibility of these procedures in patients undergoing radical hysterectomy with pelvic lymphadenectomy for early cervical cancer. A total of 30 patients with histologically diagnosed FIGO stage IA to IIA cervical cancer were enrolled to this study. They were scheduled to undergo radical abdominal hysterectomy and pelvic lymphadenectomy after injecting patent blue dye in cervix. A total of 60 SLNs (mean 2.5) were detected in 24 patients with detection rate of 80%. Bilateral SLNs were detected in 70.1% of cases. SLNs were identified in obturator and external iliac areas in 50% and 31.7%, respectively; no SLNs were discovered in the common iliac region. Seven patients (23.3%) had lymph node metastases; one of these had false negative SLN.The false negative rate and negative predictive value were 14.3% and 94.4%, respectively. SLN detection procedure with blue dye technique is a feasible procedure in cervical cancer. Patent blue dye is cheap, safe and effective tracer to detect sentinel node in carcinoma of cervix.
Jagtap, Pratik; Goslinga, Jill; Kooren, Joel A; McGowan, Thomas; Wroblewski, Matthew S; Seymour, Sean L; Griffin, Timothy J
2013-04-01
Large databases (>10(6) sequences) used in metaproteomic and proteogenomic studies present challenges in matching peptide sequences to MS/MS data using database-search programs. Most notably, strict filtering to avoid false-positive matches leads to more false negatives, thus constraining the number of peptide matches. To address this challenge, we developed a two-step method wherein matches derived from a primary search against a large database were used to create a smaller subset database. The second search was performed against a target-decoy version of this subset database merged with a host database. High confidence peptide sequence matches were then used to infer protein identities. Applying our two-step method for both metaproteomic and proteogenomic analysis resulted in twice the number of high confidence peptide sequence matches in each case, as compared to the conventional one-step method. The two-step method captured almost all of the same peptides matched by the one-step method, with a majority of the additional matches being false negatives from the one-step method. Furthermore, the two-step method improved results regardless of the database search program used. Our results show that our two-step method maximizes the peptide matching sensitivity for applications requiring large databases, especially valuable for proteogenomics and metaproteomics studies. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
2014-01-01
Background This study aimed to better understand the supporting role that mutational profiling (MP) of DNA from microdissected cytology slides and supernatant specimens may play in the diagnosis of malignancy in fine-needle aspirates (FNA) and biliary brushing specimens from patients with pancreaticobiliary masses. Methods Cytology results were examined in a total of 30 patients with associated surgical (10) or clinical (20) outcomes. MP of DNA from microdissected cytology slides and from discarded supernatant fluid was analyzed in 26 patients with atypical, negative or indeterminate cytology. Results Cytology correctly diagnosed aggressive disease in 4 patients. Cytological diagnoses for the remaining 26 were as follows: 16 negative (9 false negative), 9 atypical, 1 indeterminate. MP correctly determined aggressive disease in 1 false negative cytology case and confirmed a negative cytology diagnosis in 7 of 7 cases of non-aggressive disease. Of the 9 atypical cytology cases, MP correctly diagnosed 7 as positive and 1 as negative for aggressive disease. One specimen that was indeterminate by cytology was correctly diagnosed as non-aggressive by MP. When first line malignant (positive) cytology results were combined with positive second line MP results, 12/21 cases of aggressive disease were identified, compared to 4/21 cases identified by positive cytology alone. Conclusions When first line cytology results were uncertain (atypical), questionable (negative), or not possible (non-diagnostic/indeterminate), MP provided additional information regarding the presence of aggressive disease. When used in conjunction with first line cytology, MP increased detection of aggressive disease without compromising specificity in patients that were difficult to diagnose by cytology alone. PMID:25084836
Emotional content enhances true but not false memory for categorized stimuli.
Choi, Hae-Yoon; Kensinger, Elizabeth A; Rajaram, Suparna
2013-04-01
Past research has shown that emotion enhances true memory, but that emotion can either increase or decrease false memory. Two theoretical possibilities-the distinctiveness of emotional stimuli and the conceptual relatedness of emotional content-have been implicated as being responsible for influencing both true and false memory for emotional content. In the present study, we sought to identify the mechanisms that underlie these mixed findings by equating the thematic relatedness of the study materials across each type of valence used (negative, positive, or neutral). In three experiments, categorically bound stimuli (e.g., funeral, pets, and office items) were used for this purpose. When the encoding task required the processing of thematic relatedness, a significant true-memory enhancement for emotional content emerged in recognition memory, but no emotional boost to false memory (exp. 1). This pattern persisted for true memory with a longer retention interval between study and test (24 h), and false recognition was reduced for emotional items (exp. 2). Finally, better recognition memory for emotional items once again emerged when the encoding task (arousal ratings) required the processing of the emotional aspect of the study items, with no emotional boost to false recognition (EXP. 3). Together, these findings suggest that when emotional and neutral stimuli are equivalently high in thematic relatedness, emotion continues to improve true memory, but it does not override other types of grouping to increase false memory.
Intraoperative Evaluation of Breast Tumor Margins with Optical Coherence Tomography
Nguyen, Freddy T.; Zysk, Adam M.; Chaney, Eric J.; Kotynek, Jan G.; Oliphant, Uretz J.; Bellafiore, Frank J.; Rowland, Kendrith M.; Johnson, Patricia A.; Boppart, Stephen A.
2009-01-01
As breast cancer screening rates increase, smaller and more numerous lesions are being identified earlier, leading to more breast-conserving surgical procedures. Achieving a clean surgical margin represents a technical challenge with important clinical implications. Optical coherence tomography (OCT) is introduced as an intraoperative high-resolution imaging technique that assesses surgical breast tumor margins by providing real-time microscopic images up to 2 mm beneath the tissue surface. In a study of 37 patients split between training and study groups, OCT images covering 1 cm2 regions were acquired from surgical margins of lumpectomy specimens, registered with ink, and correlated with corresponding histological sections. A 17 patient training set used to establish standard imaging protocols and OCT evaluation criteria demonstrated that areas of higher scattering tissue with a heterogeneous pattern were indicative of tumor cells and tumor tissue, in contrast to lower scattering adipocytes found in normal breast tissue. The remaining 20 patients were enrolled into the feasibility study. Of these lumpectomy specimens, 11 were identified with a positive or close surgical margin and 9 were identified with a negative margin under OCT. Based on histological findings, 9 true positives, 9 true negatives, 2 false positives, and 0 false negatives were found, yielding a sensitivity of 100% and specificity of 82%. These results demonstrate the potential of OCT as a real-time method for intraoperative margin assessment in breast conserving surgeries. PMID:19910294
Tam, Yuk Him; Wong, Yuen Shan; Chan, Kin Wai; Pang, Kristine Kit Yi; Tsui, Siu Yan; Mou, Jennifer Wai Cheung; Sihoe, Jennifer Dart Yin; Lee, Kim Hung
2013-04-01
Transumbilical or transinguinal laparoscopic evaluation for contralateral patent processus vaginalis (CPPV) is commonly performed during laparoscopic or open hernia repair in children but may occasionally give false-negative findings. A retrospective study was conducted to compare 2 cohorts of children who underwent laparoscopic repair for clinically demonstrated unilateral inguinal hernia and evaluation for CPPV by transumbilical laparoscopy during the study periods of 2004 to 2007 (cohort 1) and 2008 to 2011 (cohort 2). Cohort 1 was a known historical cohort with CPPV being evaluated by laparoscopic inspection alone, whereas additional maneuvers were adopted in cohort 2. There were 395 and 564 patients in cohorts 1 and 2, respectively. There was no difference between the 2 cohorts in age of patients, sex distribution, laterality of clinically demonstrated inguinal hernia, and follow-up period at the time of data collection. More CPPV were diagnosed in cohort 2 than cohort 1(36.2% vs 25.8%; P < .01). 4 children (1.4%) developed metachronous inguinal hernia following negative laparoscopic evaluation for CPPV in cohort 1 compared with none from cohort 2 at a similar median follow-up period (P < .05). The additional maneuvers appear to be superior to laparoscopic inspection alone to evaluate CPPV during laparoscopic hernia repair in children. Copyright © 2013 Elsevier Inc. All rights reserved.
Accuracy of BRT and Delvotest microbial inhibition tests as affected by composition of ewe's milk.
Althaus, Rafael; Torres, Antonio; Peris, Cristofol; Beltran, M Carmen; Fernandez, Nemesio; Molina, M Pilar
2003-03-01
The presence of drug residues in ewe's milk samples can be determined by microbial assays. The main limitation of these tests is the large number of false-positive results associated with them. False-positive results can be explained by the interaction of certain substances naturally existing in ewe's milk with the growth of the microorganism used in the test. In this study, milk chemical composition (fat, protein, lactose, total solids), somatic cell counts (SCCs), free fatty acid concentrations, and lactoperoxidase system components were determined in order to investigate their influence on the rate of false-positive results for the BRT and Delvotest microbiological inhibitor tests. Milk samples were obtained after morning milking of Manchega ewes at 15, 30, 45, 60, 75, 90, 105, 120, and 135 days after parturition. The animals did not receive any kind of treatment or medicated feed throughout the experiment. The false-positive rates for BRT and Delvotest were 3.75 and 2.4%, respectively. When the logistic regression model was applied, the percentages of total solids for positive samples were significantly different from those for negative samples (16.90 versus 18.42% for BRT, 16.05 versus 18.45% for Delvotest), while the SCC logarithmic transformation was significantly higher for the positive samples than for the negative samples (5.38 versus 5.11 log units for BRT, 5.32 versus 5.11 log units for Delvotest). Moreover, Delvotest-positive samples exhibited thiocyanate concentrations higher than those of Delvotest-negative samples (8.18 mg/liter versus 6.85 mg/liter). Further analyses are needed to confirm the possible presence of antimicrobial residues in this particular type of milk sample.
Gupta, Nalini; Banik, Tarak; Rajwanshi, Arvind; Radotra, Bishan D; Panda, Naresh; Dey, Pranab; Srinivasan, Radhika; Nijhawan, Raje
2012-01-01
This study was undertaken to evaluate the diagnostic utility and pitfalls of fine needle aspiration cytology (FNAC) in oral and oropharyngeal lesions. This was a retrospective audit of oral and oropharyngeal lesions diagnosed with FNAC over a period of six years (2005-2010). Oral/oropharyngeal lesions [n=157] comprised 0.35% of the total FNAC load. The age ranged 1-80 years with the male: female ratio being 1.4:1. Aspirates were inadequate in 7% cases. Histopathology was available in 73/157 (46.5%) cases. Palate was the most common site of involvement [n=66] followed by tongue [n=35], buccal mucosa [n=18], floor of the mouth [n=17], tonsil [n=10], alveolus [n=5], retromolar trigone [n=3], and posterior pharyngeal wall [n=3]. Cytodiagnoses were categorized into infective/inflammatory lesions and benign cysts, and benign and malignant tumours. Uncommon lesions included ectopic lingual thyroid and adult rhabdomyoma of tongue, and solitary fibrous tumor (SFT), and leiomyosarcoma in buccal mucosa. A single false-positive case was dense inflammation with squamous cells misinterpreted as squamous cell carcinoma (SCC) on cytology. There were eight false-negative cases mainly due to sampling error. One false-negative case due to interpretation error was in a salivary gland tumor. The sensitivity of FNAC in diagnosing oral/oropharyngeal lesions was 71.4%; specificity was 97.8% with diagnostic accuracy of 87.7%. Salivary gland tumors and squamous cell carcinoma (SCC) are the most common lesions seen in the oral cavity. FNAC proves to be highly effective in diagnosing the spectrum of different lesions in this region. Sampling error is the main cause of false-negative cases in this region.
Validity of HydraTrend reagent strips for the assessment of hydration status.
Abbey, Bryce M; Heelan, Kate A; Brown, Gregory A; Bartee, Rodrick T
2014-09-01
Hydration is used by athletic governing organizations for weight class eligibility. The measurement of urine specific gravity (USG) as a measure of hydration by reagent strips is a controversial issue. The purpose of this study was to determine the validity of HydraTrend reagent strips that facilitate the correction of USG for alkaline urine samples against refractometry for the assessment of USG. Fifty-one participants (33 males, age = 22.3 ± 1.3 years; 18 females, age = 22.4 ± 1.2 years) provided 84 urine samples. The samples were tested for USG using refractometry and reagent strips and for pH using reagent strips and a digital pH meter. Strong correlation coefficients were found between refractometry and reagent strips for USG (rs(82) = 0.812, p < 0.01) and between reagent strips and pH meter for pH (rs(82) = 0.939, p < 0.01). It was observed that false negative results for National Collegiate Athletic Association (NCAA) requirements (fail refractometry with USG >1.020, pass reagent strips with USG ≤1.020) occurred 39% (33/84) of the time and false negative results for National Federation of State High School Association (NFHS) requirements (fail refractometry with USG >1.025, pass reagent strips with USG ≤1.025) occurred 14% (12/84) of the time. There were no false positives (pass refractometry and fail reagent strips) for NCAA or NFHS requirements. These data show that refractometry and reagent strips have strong positive correlations. However, the risk of a false negative result leading to incorrect certification of euhydration status outweighs the benefits of the HydraTrend reagent strips for the measurement of USG.
Effect of urine creatinine level during pregnancy on dipstick test.
Baba, Yosuke; Furuta, Itsuko; Zhai, Tianyue; Ohkuchi, Akihide; Yamada, Takahiro; Takahashi, Kayo; Matsubara, Shigeki; Minakami, Hisanori
2017-06-01
Dipstick results for proteinuria are affected by urine concentration, and thus urine creatinine concentration ([Cr]). This study was performed to determine whether spot urine [Cr] changes significantly during pregnancy, leading to a significantly different false-negative rate (FNR) on dipstick test between trimester. The [Cr] and protein concentrations ([P]) were analyzed in 631 spot urine samples with negative/equivocal dipstick from 425 pregnant women. False-negative dipstick was defined as [P] : [Cr] ratio (P/Cr) > 0.27 mg/mg. Median [Cr] was 117 mg/dL (range, 6.5-326 mg/dL), 72 mg/dL (range, 4.3-477 mg/dL), and 73 mg/dL (range, 8.4-396 mg/dL) in the first (n = 96), second (n = 344), and third (n = 191) trimester urine samples, respectively (P = 0.000, Kruskal-Wallis). Both [P] and P/Cr increased significantly with advancing gestation. FNR 9.4% (18/191) in the third trimester was significantly higher than that of 0.0% (0/96) in the second trimester and that of 0.5% (2/344) in the third trimester. In the 20 urine samples with false-negative dipstick, median [Cr] was 47.0 mg/dL (range, 11.0-358 mg/dL) and the proportion of samples with dilute urine, that is, [Cr] <47 mg/dL, was significantly higher than in the remaining 611 urine samples (50%, 10/20 vs 28%, 174/611, respectively, P = 0.046). Urine samples in the second and third trimesters were more likely to be diluted compared with the first trimester. This was associated with high FNR in third trimester urine samples. © 2017 Japan Society of Obstetrics and Gynecology.
FDG-PET/CT can rule out malignancy in patients with vocal cord palsy.
Thomassen, Anders; Nielsen, Anne Lerberg; Lauridsen, Jeppe Kiilerich; Blomberg, Björn Alexander; Hess, Søren; Petersen, Henrik; Johansen, Allan; Asmussen, Jon Thor; Sørensen, Jesper Roed; Johansen, Jørgen; Godballe, Christian; Høilund-Carlsen, Poul Flemming
2014-01-01
The aim was to investigate the performance of (18)F-fluorodeoxyglucose PET/CT to rule out malignancy in patients with confirmed vocal cord palsy (VCP). Between January 2011 and June 2013, we retrospectively included consecutive patients referred to PET/CT with paresis or paralysis of one or both vocal cords. PET/CT results were compared to clinical workup and histopathology. The study comprised 65 patients (32 females) with a mean age of 66±12 years (range 37-89). Eleven patients (17%) had antecedent cancer. Twenty-seven (42%) were diagnosed with cancer during follow-up. The palsy was right-sided in 24 patients, left-sided in 37, and bilateral in 4. Median follow-up was 7 months (interquartile range 4-11 months). Patients without cancer were followed for at least three months. PET/CT suggested a malignancy in 35 patients (27 true positives, 8 false positives) and showed none in 30 (30 true negatives, 0 false negatives). Thus, the sensitivity, specificity, positive and negative predictive values, and accuracy were (95% confidence intervals in parenthesis): 100% (88%-100%), 79% (64%-89%), 77% (61%-88%), 100% (89%-100%), and 88% (78%-94%), respectively. Sixteen patients had palliative treatment, while 11 were treated with curative intent, emphasising the severity of VCP and the need for a rapid and accurate diagnostic work-up. In this retrospective survey, biopsy proven malignancy (whether newly diagnosed or relapsed) was the cause of VCP in almost half of patients (42%). PET/CT had a high sensitivity (100%) with a relatively high false positive rate, but was excellent in ruling out malignancy (negative predictive value 100%).
Kabziński, Piotr; Rac, Jacek; Dorobisz, Tadeusz; Pawłowski, Wiktor; Ziomek, Agnieszka; Chabowski, Mariusz; Janczak, Dawid; Leśniak, Michał; Janczak, Dariusz
2016-05-01
At present, sentinel lymph node biopsy is a standard procedure to assess the advancement of breast cancer and cutaneous melanoma. The aim of the study was to assess the role of the sentinel lymph node biopsy in the treatment of patients with breast cancer in our own material. Analyzed was medical documentation of 258 patients with initially operable breast cancer, qualified for operation with sentinel lymph node biopsy in 2004-2014 in the Department of Surgery of the 4th Military Teaching Hospital. A few hours prior to the planned surgery, radioisotope (technitium-99 sulfur colloid) was applied in the area of tumor or under the areola. 1-2 hours after administering the tracer, the lymphoscintigraphy with the labelling of the sentinel lymph node on the skin was performed. On the basis of the gathered material, obtained were the following parameters: sensitivity - 100%, and specificity - 94.6%. Four cases were false negative (5.5%). 1. Marking the sentinel lymph node in breast cancer, based on the single visualisation method with the use of radioisotope, is a useful and effective technique. 2. The factor influencing the results of the sentinel lymph node biopsy (true positive and negative results and false negative result) was the number of the excised lymph nodes except for the sentinel lymph node. 3. Patients with estrogen receptor expression had often metastases to sentinel lymph node (145 cases - 56%). 4. The false negative rate, i.e. 5.5% in our material, is within the limits of acceptability given in the literature. 5. The sentinel lymph node biopsy performed by the experienced surgical team is a reliable diagnostic tool with a low complication rate.
[Echocardiographic diagnosis of atrial thrombosis].
Pinto Tortolero, R; Vargas Barrón, J; Rodas, M A; Díaz de la Vega, V; Horwitz, S
1982-01-01
Seventy patients with rheumatic mitral disease were studied by M-Mode and 2D echocardiography in order to detect left atrial thrombosis before surgery. Thrombosis were suspected by the observation of abnormal echoes in the left atrium. During surgery 17 (24%) patients had atrial thrombosis. It had been suspected by echocardiography in 12 (sensitivity 70%). In 53 patients thrombosis were not found during surgery; in 46 the echo had been also negative (specificity 86%). There was a false positive detection of thrombosis by echo in 7 patients (14%) and false negativity in 5 (30%). Patients with atrial thrombosis had atrial fibrilation in 91% of cases; and the most frequent valvular disease was mitral stenosis. There was not a direct relationship among existence of left atrial thrombosis and the anteroposterior diameter of the left atrium as measured by echo. We conclude that echocardiography has good specificity to rule out atrial thrombosis and moderate sensitivity to detect it in rheumatic mitral disease.
Nunes, Ludmila D.; Garcia-Marques, Leonel; Ferreira, Mário B.; Ramos, Tânia
2017-01-01
An extension of the DRM paradigm was used to study the impact of central traits (Asch, 1946) in impression formation. Traits corresponding to the four clusters of the implicit theory of personality—intellectual, positive and negative; and social, positive and negative (Rosenberg et al., 1968)—were used to develop lists containing several traits of one cluster and one central trait prototypical of the opposite cluster. Participants engaging in impression formation relative to participants engaging in memorization not only produced higher levels of false memories corresponding to the same cluster of the list traits but, under response time pressure at retrieval, also produced more false memories of the cluster corresponding to the central trait. We argue that the importance of central traits stems from their ability to activate their corresponding semantic space within a specialized associative memory structure underlying the implicit theory of personality. PMID:28878708
He, Xianmin; Wei, Qing; Sun, Meiqian; Fu, Xuping; Fan, Sichang; Li, Yao
2006-05-01
Biological techniques such as Array-Comparative genomic hybridization (CGH), fluorescent in situ hybridization (FISH) and affymetrix single nucleotide pleomorphism (SNP) array have been used to detect cytogenetic aberrations. However, on genomic scale, these techniques are labor intensive and time consuming. Comparative genomic microarray analysis (CGMA) has been used to identify cytogenetic changes in hepatocellular carcinoma (HCC) using gene expression microarray data. However, CGMA algorithm can not give precise localization of aberrations, fails to identify small cytogenetic changes, and exhibits false negatives and positives. Locally un-weighted smoothing cytogenetic aberrations prediction (LS-CAP) based on local smoothing and binomial distribution can be expected to address these problems. LS-CAP algorithm was built and used on HCC microarray profiles. Eighteen cytogenetic abnormalities were identified, among them 5 were reported previously, and 12 were proven by CGH studies. LS-CAP effectively reduced the false negatives and positives, and precisely located small fragments with cytogenetic aberrations.
Strep Test: Rapid (For Parents)
... third of negative rapid strep test results are false (meaning someone actually has a strep throat infection even though the rapid strep results were negative). A throat culture may then be done to ensure accuracy. Risks ...
Gestational Trophoblastic Disease Diagnosis Delayed by the Hook Effect.
Cormano, Julia; Mackay, Gillian; Holschneider, Christine
2015-10-01
A "hook effect" resulting from saturation of antibodies used in pregnancy tests can occur at human chorionic gonadotropin (hCG) levels above 500,000 milliinternational units/mL, resulting in falsely negative values. A 34-year-old woman, gravida 5 para 3, presented to the emergency department after heavy bleeding. Ultrasonogram revealed a uterine mass, urine pregnancy test result was negative, and endometrial biopsy inconclusive. The patient was discharged and presented 10 days later with recurrent bleeding. Urine pregnancy test result was again negative, but serum hCG was 581 milliinternational units/mL. Serial dilution revealed an actual hCG higher than 5 million milliinternational units/mL. She was diagnosed with gestational trophoblastic disease. Awareness of the risk of a false-negative pregnancy test result when hCG levels are extremely high may prevent delayed diagnosis of gestational trophoblastic disease.
Ruiz-Gutierrez, Viviana; Hooten, Melvin B.; Campbell Grant, Evan H.
2016-01-01
Biological monitoring programmes are increasingly relying upon large volumes of citizen-science data to improve the scope and spatial coverage of information, challenging the scientific community to develop design and model-based approaches to improve inference.Recent statistical models in ecology have been developed to accommodate false-negative errors, although current work points to false-positive errors as equally important sources of bias. This is of particular concern for the success of any monitoring programme given that rates as small as 3% could lead to the overestimation of the occurrence of rare events by as much as 50%, and even small false-positive rates can severely bias estimates of occurrence dynamics.We present an integrated, computationally efficient Bayesian hierarchical model to correct for false-positive and false-negative errors in detection/non-detection data. Our model combines independent, auxiliary data sources with field observations to improve the estimation of false-positive rates, when a subset of field observations cannot be validated a posteriori or assumed as perfect. We evaluated the performance of the model across a range of occurrence rates, false-positive and false-negative errors, and quantity of auxiliary data.The model performed well under all simulated scenarios, and we were able to identify critical auxiliary data characteristics which resulted in improved inference. We applied our false-positive model to a large-scale, citizen-science monitoring programme for anurans in the north-eastern United States, using auxiliary data from an experiment designed to estimate false-positive error rates. Not correcting for false-positive rates resulted in biased estimates of occupancy in 4 of the 10 anuran species we analysed, leading to an overestimation of the average number of occupied survey routes by as much as 70%.The framework we present for data collection and analysis is able to efficiently provide reliable inference for occurrence patterns using data from a citizen-science monitoring programme. However, our approach is applicable to data generated by any type of research and monitoring programme, independent of skill level or scale, when effort is placed on obtaining auxiliary information on false-positive rates.
False Memory in Adults With ADHD: A Comparison Between Subtypes and Normal Controls.
Soliman, Abdrabo Moghazy; Elfar, Rania Mohamed
2017-10-01
To examine the performance on the Deese-Roediger-McDermott task of adults divided into ADHD subtypes and compares their performance to that of healthy controls to examine whether adults with ADHD are more susceptible to the production of false memories under experimental conditions. A total of 128 adults with ADHD (50% females), classified into three Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV-TR) subtypes, were compared with 48 controls. The results indicated that the ADHD participants recalled and recognized fewer studied words than the controls, the ADHD groups produced more false memories than the control group, no differences in either the false positives or the false negatives. The ADHD-combined (ADHD-CT) group recognized significantly more critical words than the control, ADHD-predominantly inattentive (ADHD-IA), and ADHD-predominantly hyperactive-impulsive (ADHD-HI) groups. The ADHD groups recalled and recognized more false positives, were more confident in their false responses, and displayed more knowledge corruption than the controls. The ADHD-CT group recalled and recognized more false positives than the other ADHD groups. The adults with ADHD have more false memories than the controls and that false memory formation varied with the ADHD subtypes.
Use of General-purpose Negation Detection to Augment Concept Indexing of Medical Documents
Mutalik, Pradeep G.; Deshpande, Aniruddha; Nadkarni, Prakash M.
2001-01-01
Objectives: To test the hypothesis that most instances of negated concepts in dictated medical documents can be detected by a strategy that relies on tools developed for the parsing of formal (computer) languages—specifically, a lexical scanner (“lexer”) that uses regular expressions to generate a finite state machine, and a parser that relies on a restricted subset of context-free grammars, known as LALR(1) grammars. Methods: A diverse training set of 40 medical documents from a variety of specialties was manually inspected and used to develop a program (Negfinder) that contained rules to recognize a large set of negated patterns occurring in the text. Negfinder's lexer and parser were developed using tools normally used to generate programming language compilers. The input to Negfinder consisted of medical narrative that was preprocessed to recognize UMLS concepts: the text of a recognized concept had been replaced with a coded representation that included its UMLS concept ID. The program generated an index with one entry per instance of a concept in the document, where the presence or absence of negation of that concept was recorded. This information was used to mark up the text of each document by color-coding it to make it easier to inspect. The parser was then evaluated in two ways: 1) a test set of 60 documents (30 discharge summaries, 30 surgical notes) marked-up by Negfinder was inspected visually to quantify false-positive and false-negative results; and 2) a different test set of 10 documents was independently examined for negatives by a human observer and by Negfinder, and the results were compared. Results: In the first evaluation using marked-up documents, 8,358 instances of UMLS concepts were detected in the 60 documents, of which 544 were negations detected by the program and verified by human observation (true-positive results, or TPs). Thirteen instances were wrongly flagged as negated (false-positive results, or FPs), and the program missed 27 instances of negation (false-negative results, or FNs), yielding a sensitivity of 95.3 percent and a specificity of 97.7 percent. In the second evaluation using independent negation detection, 1,869 concepts were detected in 10 documents, with 135 TPs, 12 FPs, and 6 FNs, yielding a sensitivity of 95.7 percent and a specificity of 91.8 percent. One of the words “no,” “denies/denied,” “not,” or “without” was present in 92.5 percent of all negations. Conclusions: Negation of most concepts in medical narrative can be reliably detected by a simple strategy. The reliability of detection depends on several factors, the most important being the accuracy of concept matching. PMID:11687566
Dorell, Christina G.; Jain, Nidhi; Yankey, David
2011-01-01
Objective The validity of parent-reported adolescent vaccination histories has not been assessed. This study evaluated the validity of parent-reported adolescent vaccination histories by a combination of immunization card and recall, and by recall only, compared with medical provider records. Methods We analyzed data from the 2008 National Immunization Survey-Teen. Parents of adolescents aged 13–17 years reported their child's vaccination history either by immunization card and recall (n=3,661) or by recall only (n=12,822) for the hepatitis B (Hep B), measles-mumps-rubella (MMR), varicella (VAR), tetanus-diphtheria/tetanus-diphtheria-acellular pertussis (Td/Tdap), meningococcal conjugate (MCV4), and quadrivalent human papillomavirus (HPV4) (for girls only) vaccines. We validated parental report with medical records. Results Among the immunization card/recall group, vaccines with >20% false-positive reports included MMR (32.3%) and Td/Tdap (36.9%); vaccines with >20% false-negative reports included VAR (35.2%), MCV4 (36.0%), and Tdap (41.9%). Net bias ranged from −25.0 to −0.1 percentage points. Kappa values ranged from 0.22 to 0.92. Among the recall-only group, vaccines with >20% false-positive reports included Hep B (33.9%), MMR (61.4%), VAR (26.2%), and Td/Tdap (60.6%); vaccines with >20% false-negative reports included Hep B (58.9%), MMR (33.7%), VAR (51.6%), Td/Tdap (25.5%), Tdap (50.3%) MCV4 (63.0%), and HPV4 (20.5%). Net bias ranged from −46.0 to 0.5 percentage points. Kappa values ranged from 0.03 to 0.76. Conclusions Validity of parent-reported vaccination histories varies by type of report and vaccine. For recently recommended vaccines, false-negative rates were substantial and higher than false-positive rates, resulting in net underreporting of vaccination rates by both the immunization card/recall and recall-only groups. Provider validation of parent-reported vaccinations is needed for valid surveillance of adolescent vaccination coverage. PMID:21812170
The role of ethics in shale gas policies.
de Melo-Martín, Inmaculada; Hays, Jake; Finkel, Madelon L
2014-02-01
The United States has experienced a boom in natural gas production due to recent technological innovations that have enabled natural gas to be produced from unconventional sources, such as shale. There has been much discussion about the costs and benefits of developing shale gas among scientists, policy makers, and the general public. The debate has typically revolved around potential gains in economics, employment, energy independence, and national security as well as potential harms to the environment, the climate, and public health. In the face of scientific uncertainty, national and international governments must make decisions on how to proceed. So far, the results have been varied, with some governments banning the process, others enacting moratoria until it is better understood, and others explicitly sanctioning shale gas development. These policies reflect legislature's preferences to avoid false negative errors or false positive ones. Here we argue that policy makers have a prima facie duty to minimize false negatives based on three considerations: (1) protection from serious harm generally takes precedence over the enhancement of welfare; (2) minimizing false negatives in this case is more respectful to people's autonomy; and (3) alternative solutions exist that may provide many of the same benefits while minimizing many of the harms. © 2013.
False memory in aging: effects of emotional valence on word recognition accuracy.
Piguet, Olivier; Connally, Emily; Krendl, Anne C; Huot, Jessica R; Corkin, Suzanne
2008-06-01
Memory is susceptible to distortions. Valence and increasing age are variables known to affect memory accuracy and may increase false alarm production. Interaction between these variables and their impact on false memory was investigated in 36 young (18-28 years) and 36 older (61-83 years) healthy adults. At study, participants viewed lists of neutral words orthographically related to negative, neutral, or positive critical lures (not presented). Memory for these words was subsequently tested with a remember-know procedure. At test, items included the words seen at study and their associated critical lures, as well as sets of orthographically related neutral words not seen at study and their associated unstudied lures. Positive valence was shown to have two opposite effects on older adults' discrimination of the lures: It improved correct rejection of unstudied lures but increased false memory for critical lures (i.e., lures associated with words studied previously). Thus, increased salience triggered by positive valence may disrupt memory accuracy in older adults when discriminating among similar events. These findings likely reflect a source memory deficit due to decreased efficiency in cognitive control processes with aging.
Developmental reversals in false memory: Effects of emotional valence and arousal.
Brainerd, C J; Holliday, R E; Reyna, V F; Yang, Y; Toglia, M P
2010-10-01
Do the emotional valence and arousal of events distort children's memories? Do valence and arousal modulate counterintuitive age increases in false memory? We investigated those questions in children, adolescents, and adults using the Cornell/Cortland Emotion Lists, a word list pool that induces false memories and in which valence and arousal can be manipulated factorially. False memories increased with age for unpresented semantic associates of word lists, and net accuracy (the ratio of true memory to total memory) decreased with age. These surprising developmental trends were more pronounced for negatively valenced materials than for positively valenced materials, they were more pronounced for high-arousal materials than for low-arousal materials, and developmental increases in the effects of arousal were small in comparison with developmental increases in the effects of valence. These findings have ramifications for legal applications of false memory research; materials that share the emotional hallmark of crimes (events that are negatively valenced and arousing) produced the largest age increases in false memory and the largest age declines in net accuracy. Copyright 2010 Elsevier Inc. All rights reserved.
Cognitive errors: thinking clearly when it could be child maltreatment.
Laskey, Antoinette L
2014-10-01
Cognitive errors have been studied in a broad array of fields, including medicine. The more that is understood about how the human mind processes complex information, the more it becomes clear that certain situations are particularly susceptible to less than optimal outcomes because of these errors. This article explores how some of the known cognitive errors may influence the diagnosis of child abuse, resulting in both false-negative and false-positive diagnoses. Suggested remedies for these errors are offered. Copyright © 2014 Elsevier Inc. All rights reserved.
Zhao, Bo; Wang, Yan-Yan; Cao, Yun; Zhang, Hui-Qin; Zhu, Xing-Quan; He, Yong-Kang; Xia, Chao-Ming
2015-01-01
Background Schistosomiasis has decreased significantly in prevalence and intensity of infection in China, thus more accurate and sensitive methods are desperately needed for the further control of schistosomiasis. The present work aimed to assess the utility of the loop-mediated isothermal amplification (LAMP) for detection of light intensity infection or false-negative patients and patients post-treatment, targeting the highly repetitive retrotransposon SjR2 of Schistosoma japonicum. Methodology/ Principal Findings LAMP was first assessed in rabbits with low intensity infection (EPG<10). Then 110 patient sera from Hunan Province, China, and 47 sera after treatment by praziquantel were used to evaluate the diagnostic validity of LAMP. Meanwhile, 42 sera from healthy individuals in a non-endemic area, and 60 sera from "healthy” residents who were identified as being negative for feces examination and immuno-methods in an endemic area were also examined. The results showed that LAMP could detect S. japonicum DNA in sera from rabbits at 3rd day post-infection. Following administration of praziquantel, the S. japonicum DNA in rabbit sera became negative at 10 weeks post-treatment. Of 110 sera from patients, LAMP showed 95.5% sensitivity, and even for 41 patients with less than 10 EPG, the sensitivity of LAMP still reached to 95.1%. For 47 patients after treatment, the negative conversion rate of S. japonicum DNA in patient sera increased from 23.4%, 61.7% to 83.0% at 3 months, 6 months and 9 months post-treatment, respectively. No false-positive result was obtained for 42 human sera from non-endemic area, while for the 60 “healthy” individuals from endemic area, 10 (16.7%) individuals were positive by LAMP, which suggested that these individuals might be false-negative patients. Conclusions/ Significance The present study demonstrated that the LAMP assay is sensitive, specific, and affordable, which would help reduce schistosomiasis transmission through targeted treatment of individuals, particularly for those with negative stool examinations who may yet remain infected. The LAMP assay may provide a potential tool to support schistosomiasis control and elimination strategies. PMID:25874964
Xu, Jing; Guan, Zhi-Xun; Zhao, Bo; Wang, Yan-Yan; Cao, Yun; Zhang, Hui-Qin; Zhu, Xing-Quan; He, Yong-Kang; Xia, Chao-Ming
2015-04-01
Schistosomiasis has decreased significantly in prevalence and intensity of infection in China, thus more accurate and sensitive methods are desperately needed for the further control of schistosomiasis. The present work aimed to assess the utility of the loop-mediated isothermal amplification (LAMP) for detection of light intensity infection or false-negative patients and patients post-treatment, targeting the highly repetitive retrotransposon SjR2 of Schistosoma japonicum. LAMP was first assessed in rabbits with low intensity infection (EPG<10). Then 110 patient sera from Hunan Province, China, and 47 sera after treatment by praziquantel were used to evaluate the diagnostic validity of LAMP. Meanwhile, 42 sera from healthy individuals in a non-endemic area, and 60 sera from "healthy" residents who were identified as being negative for feces examination and immuno-methods in an endemic area were also examined. The results showed that LAMP could detect S. japonicum DNA in sera from rabbits at 3rd day post-infection. Following administration of praziquantel, the S. japonicum DNA in rabbit sera became negative at 10 weeks post-treatment. Of 110 sera from patients, LAMP showed 95.5% sensitivity, and even for 41 patients with less than 10 EPG, the sensitivity of LAMP still reached to 95.1%. For 47 patients after treatment, the negative conversion rate of S. japonicum DNA in patient sera increased from 23.4%, 61.7% to 83.0% at 3 months, 6 months and 9 months post-treatment, respectively. No false-positive result was obtained for 42 human sera from non-endemic area, while for the 60 "healthy" individuals from endemic area, 10 (16.7%) individuals were positive by LAMP, which suggested that these individuals might be false-negative patients. The present study demonstrated that the LAMP assay is sensitive, specific, and affordable, which would help reduce schistosomiasis transmission through targeted treatment of individuals, particularly for those with negative stool examinations who may yet remain infected. The LAMP assay may provide a potential tool to support schistosomiasis control and elimination strategies.
Publication bias and the canonization of false facts
Nissen, Silas Boye; Magidson, Tali; Gross, Kevin; Bergstrom, Carl T
2016-01-01
Science is facing a “replication crisis” in which many experimental findings cannot be replicated and are likely to be false. Does this imply that many scientific facts are false as well? To find out, we explore the process by which a claim becomes fact. We model the community’s confidence in a claim as a Markov process with successive published results shifting the degree of belief. Publication bias in favor of positive findings influences the distribution of published results. We find that unless a sufficient fraction of negative results are published, false claims frequently can become canonized as fact. Data-dredging, p-hacking, and similar behaviors exacerbate the problem. Should negative results become easier to publish as a claim approaches acceptance as a fact, however, true and false claims would be more readily distinguished. To the degree that the model reflects the real world, there may be serious concerns about the validity of purported facts in some disciplines. DOI: http://dx.doi.org/10.7554/eLife.21451.001 PMID:27995896
Goldenberg, S D; Cliff, P R; Smith, S; Milner, M; French, G L
2010-01-01
Current diagnosis of Clostridium difficile infection (CDI) relies upon detection of toxins A/B in stool by enzyme immunoassay [EIA(A/B)]. This strategy is unsatisfactory because it has a low sensitivity resulting in significant false negatives. We investigated the performance of a two-step algorithm for diagnosis of CDI using detection of glutamate dehydrogenase (GDH). GDH-positive samples were tested for C. difficile toxin B gene (tcdB) by polymerase chain reaction (PCR). The performance of the two-step protocol was compared with toxin detection by the Meridian Premier EIA kit in 500 consecutive stool samples from patients with suspected CDI. The reference standard among samples that were positive by either EIA(A/B) or GDH testing was culture cytotoxin neutralisation (culture/CTN). Thirty-six (7%) of 500 samples were identified as true positives by culture/CTN. EIA(A/B) identified 14 of the positive specimens with 22 false negatives and two false positives. The two-step protocol identified 34 of the positive samples with two false positives and two false negatives. EIA(A/B) had a sensitivity of 39%, specificity of 99%, positive predictive value of 88% and negative predictive value of 95%. The two-step algorithm performed better, with corresponding values of 94%, 99%, 94% and 99% respectively. Screening for GDH before confirmation of positives by PCR is cheaper than screening all specimens by PCR and is an effective method for routine use. Current EIA(A/B) tests for CDI are of inadequate sensitivity and should be replaced; however, this may result in apparent changes in CDI rates that would need to be explained in national surveillance statistics. Copyright 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
Kim, Sung-Hoon; Jin, Seok-Joon; Karm, Myong-Hwan; Moon, Young-Jin; Jeong, Hye-Won; Kim, Jae-Won; Ha, Seung-Il; Kim, Joung-Uk
2016-08-01
Although the elicited responses of motor evoked potential (MEP) monitoring are very sensitive to suppression by anesthetic agents and muscle relaxants, the use of neuromuscular blockade (NMB) during MEP monitoring is still controversial because of serious safety concerns and diagnostic accuracy. Here, we evaluated the incidence of unacceptable movement and compared false-negative MEP results between no and partial NMB during cerebral aneurysm clipping surgery. We reviewed patient medical records for demographic data, anesthesia regimen, neurophysiology event logs, MEP results, and clinical outcomes. Patients were divided into 2 groups according to the intraoperative use of NMB: no NMB group (n = 276) and partial NMB group (n = 409). We compared the diagnostic accuracy of MEP results to predict postoperative outcomes between both groups. Additionally, we evaluated unwanted patient movement during MEP monitoring in both groups. Of the 685 patients, 622 (90.8%) manifested no intraoperative changes in MEP and no postoperative motor deficits. Twenty patients showed postoperative neurologic deficits despite preserved intraoperative MEP. False-positive MEP results were 3.6% in the no NMB group and 3.9% in the partial NMB group (P = 1.00). False-negative MEP results were 1.1% in the no NMB group and 4.2% in the partial NMB group (P = 0.02). No spontaneous movement or spontaneous respiration was observed in either group. Propofol/remifentanil-based anesthesia without NMB decreases the stimulation intensity of MEPs, which may reduce the false-negative ratio of MEP monitoring during cerebral aneurysm surgery. Our anesthetic protocol enabled reliable intraoperative MEP recording and patient immobilization during cerebral aneurysm clipping surgery.
7 CFR 275.13 - Review of negative cases.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 4 2011-01-01 2011-01-01 false Review of negative cases. 275.13 Section 275.13... AGRICULTURE FOOD STAMP AND FOOD DISTRIBUTION PROGRAM PERFORMANCE REPORTING SYSTEM Quality Control (QC) Reviews § 275.13 Review of negative cases. (a) General. A sample of actions to deny applications, or suspend or...
21 CFR 878.4683 - Non-Powered suction apparatus device intended for negative pressure wound therapy.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Non-Powered suction apparatus device intended for... Surgical Devices § 878.4683 Non-Powered suction apparatus device intended for negative pressure wound therapy. (a) Identification. A non-powered suction apparatus device intended for negative pressure wound...
Lao, Annabelle Y; Sharma, Vijay K; Tsivgoulis, Georgios; Frey, James L; Malkoff, Marc D; Navarro, Jose C; Alexandrov, Andrei V
2008-10-01
International Consensus Criteria (ICC) consider right-to-left shunt (RLS) present when Transcranial Doppler (TCD) detects even one microbubble (microB). Spencer Logarithmic Scale (SLS) offers more grades of RLS with detection of >30 microB corresponding to a large shunt. We compared the yield of ICC and SLS in detection and quantification of a large RLS. We prospectively evaluated paradoxical embolism in consecutive patients with ischemic strokes or transient ischemic attack (TIA) using injections of 9 cc saline agitated with 1 cc of air. Results were classified according to ICC [negative (no microB), grade I (1-20 microB), grade II (>20 microB or "shower" appearance of microB), and grade III ("curtain" appearance of microB)] and SLS criteria [negative (no microB), grade I (1-10 microB), grade II (11-30 microB), grade III (31100 microB), grade IV (101300 microB), grade V (>300 microB)]. The RLS size was defined as large (>4 mm) using diameter measurement of the septal defects on transesophageal echocardiography (TEE). TCD comparison to TEE showed 24 true positive, 48 true negative, 4 false positive, and 2 false negative cases (sensitivity 92.3%, specificity 92.3%, positive predictive value (PPV) 85.7%, negative predictive value (NPV) 96%, and accuracy 92.3%) for any RLS presence. Both ICC and SLS were 100% sensitive for detection of large RLS. ICC and SLS criteria yielded a false positive rate of 24.4% and 7.7%, respectively when compared to TEE. Although both grading scales provide agreement as to any shunt presence, using the Spencer Scale grade III or higher can decrease by one-half the number of false positive TCD diagnoses to predict large RLS on TEE.
[Analysis for Discordance of Positive and Negative Blood Typing by Gel Card].
Li, Cui-Ying; Xu, Hong; Lei, Hui-Fen; Liu, Juan; Li, Xiao-Wei
2017-08-01
To explore the method of Gel card identifying ABO blood group, determine the inconsistent cause and the distribution of disease affecting factors, and put forward a method of its solutions. To collect 240 positive and negative typing-discordant blood speciments from patients examined by Gel card and send these speciments to blood type reference laboratory for examining with the classic tube method and serological test, such as salivary blood-group substance, in order to performe genotyping method when serologic test can not be determined. Among 240 positive and negative typing-discordant blood speciments from patients examined by Gel card, 107 blood speciments were positive and negative consistent examined by false agglutination test (44.58%), 133 blood specinents were discordent examined by false agglutination (55.42%), out of them, 35 cases (14.58%) with inconsistent cold agglutination test, 22 cases (9.17%) with weakened AB antigenicity, 16 cases (6.67%) with ABO subtyping, 12 cases (5.00%) with positive direct antiglobulin test, 11 cases (4.58%) with reduced or without antibodies, 11 cases (4.58%) with false aggregation caused by drugs or protein, 11 cases (4.58%) with salivary blood-type substances, 8 cases (3.33%) with non-ABO alloantibody, and 7 cases (2.92%) with allogeneic bone marrow transplantation. The distribution of disease were following: blood disease (16.83%), tumor (11.88%), and cardiopulmonary diseases (11.39%); chi-square test results indicated that the distribution significantly different. The analysis of ABO blood grouping shows a variety factors influencing positive and negative blood typing, and the Gel Card identification can produc more false positive blood types. Therefore, more attention should be paid on the high incidence diseases, such as blood disease, tumor, and cardiopulmonary disease.
Jacobsberg, L; Perry, S; Frances, A
1995-12-01
Instruments to assess personality disorders offer reliability, but at the cost of large amounts of a skilled clinician's time to make assessments. The Structured Clinical Interview for DSM-III Axis II (SCID-II; Spitzer, Williams, Gibbon, & First, 1990), incorporates a self-report screening questionnaire, reducing the number of items needing evaluation by the interviewer. However, false negative responses may cause clinically important areas to be overlooked. To establish the rate of false negative responses, we compared participant self-report on the SCID-II with Axis II diagnostic assessment done by clinicians using the Personality Disorder Examination (Loranger, Susman, Oldham, & Russakoff, 1987). The false negative rate was low for every diagnosis, supporting validity of following up with clinician questioning only those diagnostic elements endorsed in the self-report. Avoidant and dependent personality disorders were accurately self-reported. This, an efficient assessment instrument for personality disorders might combine self-report of those disorders where self-report is reliable, with clinician assessment where needed.
de Haas, Masja; Thurik, Florentine F; van der Ploeg, Catharina P B; Veldhuisen, Barbera; Hirschberg, Hoang; Soussan, Aicha Ait; Woortmeijer, Heleen; Abbink, Frithjofna; Page-Christiaens, Godelieve C M L; Scheffer, Peter G; Ellen van der Schoot, C
2016-11-07
To determine the accuracy of non-invasive fetal testing for the RHD gene in week 27 of pregnancy as part of an antenatal screening programme to restrict anti-D immunoglobulin use to women carrying a child positive for RHD DESIGN: Prospectively monitoring of fetal RHD testing accuracy compared with serological cord blood typing on introduction of the test. Fetal RHD testing was performed with a duplex real time quantitative polymerase chain reaction, with cell-free fetal DNA isolated from 1 mL of maternal plasma The study period was between 4 July 2011 and 7 October 2012. The proportion of women participating in screening was determined. Nationwide screening programme, the Netherlands. Tests are performed in a centralised setting. 25 789 RhD negative pregnant women. Sensitivity, specificity, false negative rate, and false positive rate of fetal RHD testing compared with serological cord blood typing; proportion of technical failures; and compliance to the screening programme. A fetal RHD test result and serological cord blood result were available for 25 789 pregnancies. Sensitivity for detection of fetal RHD was 99.94% (95% confidence interval 99.89% to 99.97%) and specificity was 97.74% (97.43% to 98.02%). Nine false negative results for fetal RHD testing were registered (0.03%, 95% confidence interval 0.01% to 0.06%). In two cases these were due to technical failures. False positive fetal RHD testing results were registered for 225 samples (0.87%, 0.76% to 0.99%). Weak RhD expression was shown in 22 of these cases, justifying anti-D immunoglobulin use. The negative and positive predictive values were 99.91% (95% confidence interval 99.82% to 99.95%) and 98.60% (98.40% to 98.77%), respectively. More than 98% of the women participated in the screening programme. Fetal RHD testing in week 27 of pregnancy as part of a national antenatal screening programme is highly reliable and can be used to target both antenatal and postnatal anti-D immunoglobulin use. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Fredrickson, Michael J
2008-01-01
Neurostimulation during single shot interscalene block has a significant false negative motor response rate. Compared with tangential needle approaches for single shot block, interscalene catheter (ISC) placement commonly involves Tuohy needles inserted longitudinally to the brachial plexus. This study aimed to determine the sensitivity of neurostimulation during ultrasound-guided ISC needle placement, and the feasibility of an ultrasound-guided ISC needle endpoint. One hundred fifty-five consecutive nonstimulating ISCs were placed with the needle tip position confirmed by the sonographic spread of 5 mL dextrose 5%. Catheter advancement was then blind 2 to 3 cm past the needle tip. A 0.8 mA electrical stimulus at 2 Hz was applied throughout. When a satisfactory image was obtained, neurostimulation was ignored and the minimum motor response amplitude noted. If imaging was equivocal, a brief appropriate motor response at 0.8 mA was sought. A sustained response at <0.5 mA was only sought if imaging was suboptimal. Prior to surgery conducted under general anesthesia, 30 mL ropivacaine 0.5% was administered through the ISC. Catheter success was defined as a recovery room numerical rating pain score of =2 (scale, 0-10). In 57% of patients, a muscle response was not elicited. An ultrasound needle endpoint was used in 92% of ISC placements, of which 96% were successful. Sustained twitches at <0.5 mA were obtained in 12 (8%) patients, 6 (4%) of these deliberately sought because of suboptimal imaging. Catheter success overall was 95%. This study suggests that the false negative motor response rate for longitudinal ISC needle placement is higher than the false negative response rate associated with tangential needle approach interscalene block. An ultrasound guided ISC needle endpoint is a feasible alternative to a neurostimulation endpoint.
Establishing a sample-to cut-off ratio for lab-diagnosis of hepatitis C virus in Indian context.
Tiwari, Aseem K; Pandey, Prashant K; Negi, Avinash; Bagga, Ruchika; Shanker, Ajay; Baveja, Usha; Vimarsh, Raina; Bhargava, Richa; Dara, Ravi C; Rawat, Ganesh
2015-01-01
Lab-diagnosis of hepatitis C virus (HCV) is based on detecting specific antibodies by enzyme immuno-assay (EIA) or chemiluminescence immuno-assay (CIA). Center for Disease Control reported that signal-to-cut-off (s/co) ratios in anti-HCV antibody tests like EIA/CIA can be used to predict the probable result of supplemental test; above a certain s/co value it is most likely to be true-HCV positive result and below that certain s/co it is most likely to be false-positive result. A prospective study was undertaken in patients in tertiary care setting for establishing this "certain" s/co value. The study was carried out in consecutive patients requiring HCV testing for screening/diagnosis and medical management. These samples were tested for anti-HCV on CIA (VITROS(®) Anti-HCV assay, Ortho-Clinical Diagnostics, New Jersey) for calculating s/co value. The supplemental nucleic acid test used was polymerase chain reaction (PCR) (Abbott). PCR test results were used to define true negatives, false negatives, true positives, and false positives. Performance of different putative s/co ratios versus PCR was measured using sensitivity, specificity, positive predictive value and negative predictive value and most appropriate s/co was considered on basis of highest specificity at sensitivity of at least 95%. An s/co ratio of ≥6 worked out to be over 95% sensitive and almost 92% specific in 438 consecutive patient samples tested. The s/co ratio of six can be used for lab-diagnosis of HCV infection; those with s/co higher than six can be diagnosed to have HCV infection without any need for supplemental assays.
Wei, Wei-Qi; Leibson, Cynthia L; Ransom, Jeanine E; Kho, Abel N; Caraballo, Pedro J; Chai, High Seng; Yawn, Barbara P; Pacheco, Jennifer A
2012-01-01
Objective To evaluate data fragmentation across healthcare centers with regard to the accuracy of a high-throughput clinical phenotyping (HTCP) algorithm developed to differentiate (1) patients with type 2 diabetes mellitus (T2DM) and (2) patients with no diabetes. Materials and methods This population-based study identified all Olmsted County, Minnesota residents in 2007. We used provider-linked electronic medical record data from the two healthcare centers that provide >95% of all care to County residents (ie, Olmsted Medical Center and Mayo Clinic in Rochester, Minnesota, USA). Subjects were limited to residents with one or more encounter January 1, 2006 through December 31, 2007 at both healthcare centers. DM-relevant data on diagnoses, laboratory results, and medication from both centers were obtained during this period. The algorithm was first executed using data from both centers (ie, the gold standard) and then from Mayo Clinic alone. Positive predictive values and false-negative rates were calculated, and the McNemar test was used to compare categorization when data from the Mayo Clinic alone were used with the gold standard. Age and sex were compared between true-positive and false-negative subjects with T2DM. Statistical significance was accepted as p<0.05. Results With data from both medical centers, 765 subjects with T2DM (4256 non-DM subjects) were identified. When single-center data were used, 252 T2DM subjects (1573 non-DM subjects) were missed; an additional false-positive 27 T2DM subjects (215 non-DM subjects) were identified. The positive predictive values and false-negative rates were 95.0% (513/540) and 32.9% (252/765), respectively, for T2DM subjects and 92.6% (2683/2898) and 37.0% (1573/4256), respectively, for non-DM subjects. Age and sex distribution differed between true-positive (mean age 62.1; 45% female) and false-negative (mean age 65.0; 56.0% female) T2DM subjects. Conclusion The findings show that application of an HTCP algorithm using data from a single medical center contributes to misclassification. These findings should be considered carefully by researchers when developing and executing HTCP algorithms. PMID:22249968
Locketz, Garrett D; Li, Peter M M C; Fischbein, Nancy J; Holdsworth, Samantha J; Blevins, Nikolas H
2016-10-01
A method to optimize imaging of cholesteatoma by combining the strengths of available modalities will improve diagnostic accuracy and help to target treatment. To assess whether fusing Periodically Rotated Overlapping Parallel Lines With Enhanced Reconstruction (PROPELLER) diffusion-weighted magnetic resonance imaging (DW-MRI) with corresponding temporal bone computed tomography (CT) images could increase cholesteatoma diagnostic and localization accuracy across 6 distinct anatomical regions of the temporal bone. Case series and preliminary technology evaluation of adults with preoperative temporal bone CT and PROPELLER DW-MRI scans who underwent surgery for clinically suggested cholesteatoma at a tertiary academic hospital. When cholesteatoma was encountered surgically, the precise location was recorded in a diagram of the middle ear and mastoid. For each patient, the 3 image data sets (CT, PROPELLER DW-MRI, and CT-MRI fusion) were reviewed in random order for the presence or absence of cholesteatoma by an investigator blinded to operative findings. If cholesteatoma was deemed present on review of each imaging modality, the location of the lesion was mapped presumptively. Image analysis was then compared with surgical findings. Twelve adults (5 women and 7 men; median [range] age, 45.5 [19-77] years) were included. The use of CT-MRI fusion had greater diagnostic sensitivity (0.88 vs 0.75), positive predictive value (0.88 vs 0.86), and negative predictive value (0.75 vs 0.60) than PROPELLER DW-MRI alone. Image fusion also showed increased overall localization accuracy when stratified across 6 distinct anatomical regions of the temporal bone (localization sensitivity and specificity, 0.76 and 0.98 for CT-MRI fusion vs 0.58 and 0.98 for PROPELLER DW-MRI). For PROPELLER DW-MRI, there were 15 true-positive, 45 true-negative, 1 false-positive, and 11 false-negative results; overall accuracy was 0.83. For CT-MRI fusion, there were 20 true-positive, 45 true-negative, 1 false-positive, and 6 false-negative results; overall accuracy was 0.90. The poor anatomical spatial resolution of DW-MRI makes precise localization of cholesteatoma within the middle ear and mastoid a diagnostic challenge. This study suggests that the bony anatomic detail obtained via CT coupled with the excellent sensitivity and specificity of PROPELLER DW-MRI for cholesteatoma can improve both preoperative identification and localization of disease over DW-MRI alone.
Franson, J.C.; Hohman, W.L.; Moore, J.L.; Smith, M.R.
1996-01-01
We used 363 blood samples collected from wild canvasback dueks (Aythya valisineria) at Catahoula Lake, Louisiana, U.S.A. to evaluate the effect of sample storage time on the efficacy of erythrocytic protoporphyrin as an indicator of lead exposure. The protoporphyrin concentration of each sample was determined by hematofluorometry within 5 min of blood collection and after refrigeration at 4 °C for 24 and 48 h. All samples were analyzed for lead by atomic absorption spectrophotometry. Based on a blood lead concentration of ≥0.2 ppm wet weight as positive evidence for lead exposure, the protoporphyrin technique resulted in overall error rates of 29%, 20%, and 19% and false negative error rates of 47%, 29% and 25% when hematofluorometric determinations were made on blood at 5 min, 24 h, and 48 h, respectively. False positive error rates were less than 10% for all three measurement times. The accuracy of the 24-h erythrocytic protoporphyrin classification of blood samples as positive or negative for lead exposure was significantly greater than the 5-min classification, but no improvement in accuracy was gained when samples were tested at 48 h. The false negative errors were probably due, at least in part, to the lag time between lead exposure and the increase of blood protoporphyrin concentrations. False negatives resulted in an underestimation of the true number of canvasbacks exposed to lead, indicating that hematofluorometry provides a conservative estimate of lead exposure.
Shahi, Prinka; Sood, P B; Sharma, Arun; Madan, Manish; Shahi, Nishat; Gandhi, Geetanjali
2015-01-01
The purpose of this study was to compare the pulp testing methods (pulse oximetry and electric pulp test) in primary and young permanent teeth of children. The study included a total of 155 children aged 4 to 15 years. Twenty children formed control group I. Study group included all healthy, 85 primary 2nd molars in group II and 85 permanent 1st molars in group III. Fifty children needing endodontics treatment formed test group IV. The readings were recorded as true positive (TP), false positive (FP), true negative (TN), false negative (FN). Based on this, the sensitivity, specificity, positive predictive value and negative predictive value were calculated for each method. The results were statistically analyzed using Chi-square test. On comparing pulse oximetry with electric pulp test 'p-value' was found to be 0.487 and 1.00 for groups 1 and 2 respectively and was statistically not significant. Whereas 'p-value' for groups 3 and 4 was < 0.0001 and 0.003 respectively and was statistically highly significant. The present study indicates that pulse oximetry can be used as a routine method for assessing the pulp vitality in primary, young permanent and mature permanent teeth. How to cite this article: Shahi P, Sood PB, Sharma A, Madan M, Shahi N, Gandhi G. Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester. Int J Clin Pediatr Dent 2015;8(2):94-98.
Basketter, David A; Gerberick, G Frank; Kimber, Ian
2007-01-01
The local lymph node assay (LLNA) is being used increasingly in the identification of skin sensitizing chemicals for regulatory purposes. In the context of new chemicals legislation (REACH) in Europe, it is the preferred assay. The rationale for this is that the LLNA quantitative and objective approach to skin sensitization testing allied with the important animal welfare benefits that the method offers. However, as with certain guinea pig sensitization tests before it, this increasing use also brings experience with an increasingly wide range of industrial and other chemicals where the outcome of the assay does not always necessarily meet with the expectations of those conducting it. Sometimes, the result appears to be a false negative, but rather more commonly, the complaint is that the chemical represents a false positive. Against this background we have here reviewed a number of instances where false positive and false negative results have been described and have sought to reconcile science with expectation. Based on these analyses, it is our conclusion that false positives and false negatives do occur in the LLNA, as they do with any other skin sensitization assay (and indeed with all tests used for hazard identification), and that this occurs for a number of reasons. We further conclude, however, that false positive results in the LLNA, as with the guinea pig maximization test, arise most commonly via failure to distinguish what is scientifically correct from that which is unpalatable. The consequences of this confusion are discussed in the article, particularly in relation to the need to integrate both potency measurement and risk assessments into classification and labelling schemes that aim to manage potential risks to human health.
Gong, Xianmin; Xiao, Hongrui; Wang, Dahua
2016-11-01
False recognition results from the interplay of multiple cognitive processes, including verbatim memory, gist memory, phantom recollection, and response bias. In the current study, we modified the simplified Conjoint Recognition (CR) paradigm to investigate the way in which the valence of emotional stimuli affects the cognitive process and behavioral outcome of false recognition. In Study 1, we examined the applicability of the modification to the simplified CR paradigm and model. Twenty-six undergraduate students (13 females, aged 21.00±2.30years) learned and recognized both the large and small categories of photo objects. The applicability of the paradigm and model was confirmed by a fair goodness-of-fit of the model to the observational data and by their competence in detecting the memory differences between the large- and small-category conditions. In Study 2, we recruited another sample of 29 undergraduate students (14 females, aged 22.60±2.74years) to learn and recognize the categories of photo objects that were emotionally provocative. The results showed that negative valence increased false recognition, particularly the rate of false "remember" responses, by facilitating phantom recollection; positive valence did not influence false recognition significantly though enhanced gist processing. Copyright © 2016 Elsevier B.V. All rights reserved.
Mariaux, Sandrine; Furustrand Tafin, Ulrika; Borens, Olivier
2018-01-01
Introduction : When treating periprosthetic joint infection with a two-stage procedure, antibiotic-impregnated spacers can be used in the interval between prosthetic removal and reimplantation. In our experience, cultures of sonicated spacers are most often negative. The objective of the study was to assess whether that sonication causes an elution of antibiotics, leading to elevated antibiotic concentrations in the sonication fluid inhibiting bacterial growth and thus causing false-negative cultures. Methods : A prospective monocentric study was performed from September 2014 to March 2016. Inclusion criteria were a two-stage procedure for prosthetic infection and agreement of the patient to participate in the study. Spacers were made of gentamicin-containing cement to which tobramycin and vancomycin were added. Antibiotic concentrations in the sonication fluid were determined by mass-spectometry (LC-MS). Results : 30 patients were identified (15 hip and 14 knee and 1 ankle arthroplasties). No cases of culture positive sonicated spacer fluid were observed in our serie. In the sonication fluid median concentrations of 13.2µg/ml, 392 µg/ml and 16.6 µg/ml were detected for vancomycin, tobramycin and gentamicin, respectively. According to the European Committee on antimicrobial susceptibility testing (EUCAST), these concentrations released from cement spacer during sonication are higher than the minimal inhibitory concentrations (MICs) for most bacteria relevant in prosthetic joint infections. Conclusion: Spacer sonication cultures remained sterile in all of our cases. Elevated concentrations of antibiotics released during sonication could explain partly negative-cultured sonicated spacers. Indeed, the absence of antibiotic free interval during the two-stages can also contribute to false-negative spacers sonicated cultures.
Automatic mouse ultrasound detector (A-MUD): A new tool for processing rodent vocalizations
Reitschmidt, Doris; Noll, Anton; Balazs, Peter; Penn, Dustin J.
2017-01-01
House mice (Mus musculus) emit complex ultrasonic vocalizations (USVs) during social and sexual interactions, which have features similar to bird song (i.e., they are composed of several different types of syllables, uttered in succession over time to form a pattern of sequences). Manually processing complex vocalization data is time-consuming and potentially subjective, and therefore, we developed an algorithm that automatically detects mouse ultrasonic vocalizations (Automatic Mouse Ultrasound Detector or A-MUD). A-MUD is a script that runs on STx acoustic software (S_TOOLS-STx version 4.2.2), which is free for scientific use. This algorithm improved the efficiency of processing USV files, as it was 4–12 times faster than manual segmentation, depending upon the size of the file. We evaluated A-MUD error rates using manually segmented sound files as a ‘gold standard’ reference, and compared them to a commercially available program. A-MUD had lower error rates than the commercial software, as it detected significantly more correct positives, and fewer false positives and false negatives. The errors generated by A-MUD were mainly false negatives, rather than false positives. This study is the first to systematically compare error rates for automatic ultrasonic vocalization detection methods, and A-MUD and subsequent versions will be made available for the scientific community. PMID:28727808
Petruševska, Marija; Urleb, Uroš; Peternel, Luka
2013-11-01
The excipient-mediated precipitation inhibition is classically determined by the quantification of the dissolved compound in the solution. In this study, two alternative approaches were evaluated, one is the light scattering (nephelometer) and other is the turbidity (plate reader) microtiter plate-based methods which are based on the quantification of the compound precipitate. Following the optimization of the nephelometer settings (beam focus, laser gain) and the experimental conditions, the screening of 23 excipients on the precipitation inhibition of poorly soluble fenofibrate and dipyridamole was performed. The light scattering method resulted in excellent correlation (r>0.91) between the calculated precipitation inhibitor parameters (PIPs) and the precipitation inhibition index (PI(classical)) obtained by the classical approach for fenofibrate and dipyridamole. Among the evaluated PIPs AUC100 (nephelometer) resulted in only four false positives and lack of false negatives. In the case of the turbidity-based method a good correlation of the PI(classical) was obtained for the PIP maximal optical density (OD(max), r=0.91), however, only for fenofibrate. In the case of the OD(max) (plate reader) five false positives and two false negatives were identified. In conclusion, the light scattering-based method outperformed the turbidity-based one and could be reliably used for identification of novel precipitation inhibitors. Copyright © 2013 Elsevier B.V. All rights reserved.
Langeslag-Smith, Miriam A; Vandal, Alain C; Briane, Vincent; Thompson, Benjamin; Anstice, Nicola S
2015-01-01
Objectives To assess the accuracy of preschool vision screening in a large, ethnically diverse, urban population in South Auckland, New Zealand. Design Retrospective longitudinal study. Methods B4 School Check vision screening records (n=5572) were compared with hospital eye department data for children referred from screening due to impaired acuity in one or both eyes who attended a referral appointment (n=556). False positive screens were identified by comparing screening data from the eyes that failed screening with hospital data. Estimation of false negative screening rates relied on data from eyes that passed screening. Data were analysed using logistic regression modelling accounting for the high correlation between results for the two eyes of each child. Primary outcome measure Positive predictive value of the preschool vision screening programme. Results Screening produced high numbers of false positive referrals, resulting in poor positive predictive value (PPV=31%, 95% CI 26% to 38%). High estimated negative predictive value (NPV=92%, 95% CI 88% to 95%) suggested most children with a vision disorder were identified at screening. Relaxing the referral criteria for acuity from worse than 6/9 to worse than 6/12 improved PPV without adversely affecting NPV. Conclusions The B4 School Check generated numerous false positive referrals and consequently had a low PPV. There is scope for reducing costs by altering the visual acuity criterion for referral. PMID:26614622
Lewis, Melissa A.; Neighbors, Clayton; Geisner, Irene Markman; Lee, Christine M.; Kilmer, Jason R.; Atkins, David C.
2009-01-01
The present study examined a range of injunctive norms for alcohol use and related consequences from less severe behaviors (e.g., drinking with friends) to more severe behaviors (e.g., drinking enough alcohol to pass out), and their relationship with alcohol consumption and alcohol-related negative consequences among college students. In addition, this research aimed to determine if these relationships between injunctive norms and consequences were moderated by alcohol consumption and level of identification with the typical same-sex college student. A random sample (N = 1,002) of undergraduates (56.9% female) completed a Web–based survey that was comprised of measures of drinking behavior, perceived approval of drinking behaviors that ranged in severity (i.e., injunctive norms), and level of identification with the typical same-sex college student. Results suggest that the association between negative consequences and injunctive drinking norms depend on one's own drinking behavior, identification with other students, and the severity of the alcohol use and related consequences for which injunctive norms are assessed. Findings are discussed in terms of false consensus and false uniqueness effects, and deviance regulation perspectives. Implications for preventative interventions are discussed. PMID:20565144
Relations between mental verb and false belief understanding in Cantonese-speaking children.
Cheung, Him; Chen, Hsuan-Chih; Yeung, William
2009-10-01
Previous research has shown that linguistic forms that codify mental contents bear a specific relation with children's false belief understanding. These forms include mental verbs and their following complements, yet the two have not been considered separately. The current study examined the roles of mental verb semantics and the complement syntax in children's false belief understanding. Independent tasks were used to measure verb meaning, complements, and false belief understanding such that the verbs in question were present only in the verb meaning test, and no linguistic devices biased toward false belief were used in the false belief test. We focused on (a) some mental verbs that obligatorily affirm or negate what follows and (b) sentential complements, the content of which is to be evaluated against the mind of another person, not reality. Results showed that only (a) predicted false belief understanding in a group of Cantonese-speaking 4-year-olds, controlling for nonverbal intelligence and general language ability. In particular, children's understanding of the strong nonfactive semantics of the Cantonese verbs /ji5-wai4/ ("falsely think") predicted false belief understanding most strongly. The current findings suggest that false belief understanding is specifically related to the comprehension of mental verbs that entail false thought in their semantics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, James Christopher; Rennie, John Alan; Toevs, James Waldo
The introduction points out that radiation backgrounds fluctuate across very short distances: factors include geology, soil composition, altitude, building structures, topography, and other manmade structures; and asphalt and concrete can vary significantly over short distances. Brief descriptions are given of the detection system, experimental setup, and background variation measurements. It is concluded that positive and negative gradients can greatly reduce the detection sensitivity of an MDS: negative gradients create opportunities for false negatives (nondetection), and positive gradients create a potentially unacceptable FAR (above 1%); the location of use for mobile detection is important to understand; spectroscopic systems provide more informationmore » for screening out false alarms and may be preferred for mobile use; and mobile monitor testing at LANL accounts for expected variations in the background.« less
Possible Correlation of Transfusion Transmitted Diseases with Rh type and ABO Blood Group System
Tyagi, Surabhi; Tyagi, Alok
2013-01-01
Background: Screening of blood is mandatory for transfusion transmitted diseases and is routinely done in the blood banks. As blood is the major source transmission of hepatitis B, hepatitis C, human immunodeficiency virus & many other diseases the hazards can be minimised by effective donor selection and screening. Aim: To find out the correlation between the transfusion transmitted diseases and blood groups and the seroprevalence of HIV, HBV, HCV & syphilis among the apparently healthy human blood donors. Study, Setting & Design: This retrospective study was conducted at the blood bank of a tertiary health care teaching centre for a period of four years. Material and Methods: All voluntary and replacement donors reporting to the blood bank were screened for HIV-1 & 2, HBsAg, HCV and Syphilis. Anti–HIV -1 & 2, HBsAg & anti - HCV was tested using the appropriate Enzyme–linked immunosorbent assay (ELISA) technique using micro–elisa kit supplied by J.Mitra & Co.Ltd. The seropositive samples were again tested on ELISA kits of RFCL &/or BIORAD for further confirmation & ruling out any false positive or false negative results. The rapid plasma reagain (RPR) test was used for estimation of syphilis infection. Statistical Analysis: The data entry was carried out using Microsoft office excel worksheet and was analysed by percentage and comparison. Results: Total of 6000 donors were screened which included voluntary and replacement donors. Seroprevalence of HIV (0.1833 %), HCV (1.28%), HBsAg (1.5833 %) and syphilis (0.4333 %) was detected. In the study done it was also noted - that the NEGATIVE blood groups were more prone to TTIs. Blood group A negative was more prone to TTIs with HIV, HBsAg and VDRL while blood group B negative was more affected by HCV. Conclusion: Seroprevalence of these infections shows that routine screening is a must for blood and blood product safe transfusion. Do negative blood groups predispose to TTIs? A finding which makes us think…. PMID:24179900
Possible Correlation of Transfusion Transmitted Diseases with Rh type and ABO Blood Group System.
Tyagi, Surabhi; Tyagi, Alok
2013-09-01
Screening of blood is mandatory for transfusion transmitted diseases and is routinely done in the blood banks. As blood is the major source transmission of hepatitis B, hepatitis C, human immunodeficiency virus & many other diseases the hazards can be minimised by effective donor selection and screening. To find out the correlation between the transfusion transmitted diseases and blood groups and the seroprevalence of HIV, HBV, HCV & syphilis among the apparently healthy human blood donors. Study, Setting & Design: This retrospective study was conducted at the blood bank of a tertiary health care teaching centre for a period of four years. All voluntary and replacement donors reporting to the blood bank were screened for HIV-1 & 2, HBsAg, HCV and Syphilis. Anti-HIV -1 & 2, HBsAg & anti - HCV was tested using the appropriate Enzyme-linked immunosorbent assay (ELISA) technique using micro-elisa kit supplied by J.Mitra & Co.Ltd. The seropositive samples were again tested on ELISA kits of RFCL &/or BIORAD for further confirmation & ruling out any false positive or false negative results. The rapid plasma reagain (RPR) test was used for estimation of syphilis infection. The data entry was carried out using Microsoft office excel worksheet and was analysed by percentage and comparison. Total of 6000 donors were screened which included voluntary and replacement donors. Seroprevalence of HIV (0.1833 %), HCV (1.28%), HBsAg (1.5833 %) and syphilis (0.4333 %) was detected. In the study done it was also noted - that the NEGATIVE blood groups were more prone to TTIs. Blood group A negative was more prone to TTIs with HIV, HBsAg and VDRL while blood group B negative was more affected by HCV. Seroprevalence of these infections shows that routine screening is a must for blood and blood product safe transfusion. Do negative blood groups predispose to TTIs? A finding which makes us think….
Gene expression information improves reliability of receptor status in breast cancer patients
Kenn, Michael; Schlangen, Karin; Castillo-Tong, Dan Cacsire; Singer, Christian F.; Cibena, Michael; Koelbl, Heinz; Schreiner, Wolfgang
2017-01-01
Immunohistochemical (IHC) determination of receptor status in breast cancer patients is frequently inaccurate. Since it directs the choice of systemic therapy, it is essential to increase its reliability. We increase the validity of IHC receptor expression by additionally considering gene expression (GE) measurements. Crisp therapeutic decisions are based on IHC estimates, even if they are borderline reliable. We further improve decision quality by a responsibility function, defining a critical domain for gene expression. Refined normalization is devised to file any newly diagnosed patient into existing data bases. Our approach renders receptor estimates more reliable by identifying patients with questionable receptor status. The approach is also more efficient since the rate of conclusive samples is increased. We have curated and evaluated gene expression data, together with clinical information, from 2880 breast cancer patients. Combining IHC with gene expression information yields a method more reliable and also more efficient as compared to common practice up to now. Several types of possibly suboptimal treatment allocations, based on IHC receptor status alone, are enumerated. A ‘therapy allocation check’ identifies patients possibly miss-classified. Estrogen: false negative 8%, false positive 6%. Progesterone: false negative 14%, false positive 11%. HER2: false negative 2%, false positive 50%. Possible implications are discussed. We propose an ‘expression look-up-plot’, allowing for a significant potential to improve the quality of precision medicine. Methods are developed and exemplified here for breast cancer patients, but they may readily be transferred to diagnostic data relevant for therapeutic decisions in other fields of oncology. PMID:29100391
Deep venous thrombophlebitis: detection with 4-hour versus 24-hour platelet scintigraphy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seabold, J.E.; Conrad, G.R.; Ponto, J.A.
Thirty-one nonheparinized patients with suspected deep venous thrombophlebitis (DVT) underwent contrast venography and indium-111 platelet scintigraphy (In-111 PS). Venography permitted identification of acute DVT in 12 of 31 cases (39%). One additional patient was considered to have acute DVT despite nonconclusive venography results. In-111 PS results were positive at 4 hours in nine of 13 cases (69%) and at 24 hours in 12 of 13 cases (92%). Two of four patients with false-negative 4-hour In-111 PS studies had received warfarin. Thus, the sensitivity of 4-hour In-111 PS in patients not receiving anticoagulants was 82%. Venography results were negative for acutemore » DVT in 18 cases, and 4-hour In-111 PS studies were negative or equivocal in each. In-111 PS is an alternative to contrast venography for detecting acute DVT. If 4-hour In-111 PS results are positive, anticoagulation can be initiated. Delayed images are necessary if the 4-hour images are negative or equivocal.« less
Almawazini, Abdulmajid M; Hanafi, Hamdi K; Madkhali, Hasan A; Majrashi, Noura B
2017-10-01
To evaluate the effectiveness of critical congenital heart disease (CCHD) screening program for early diagnosis of cardiac anomalies in newborn infants. Methods: This is a hospital-based prospective cross-sectional study conducted in the Pediatric and Neonatology Department, King Fahad Hospital at Albaha, Saudi Arabia, between February 2016 and February 2017. Results: We screened 2961 (95.4%) of 3103 patients in a nursery unit; 142 (4.6%) patients were not screened. The test was positive in 114 (3.9%) patients and negative in 2847 (96.1%). There were 94 (3.2%) false positives and 20 (0.7%) true positives. Critical cardiac defects were diagnosed in 7 (0.2%) patients of all screened infants, and severe pulmonary hypertension was diagnosed in 13 (0.4%) patients. True negative results were found in 2841(96%) patients, and no cardiac defect was diagnosed, whereas false negative results were seen in 6 (0.2%) patients diagnosed with ventricular septal defect. The sensitivity was 77%, and the specificity was very high at 97%, with a positive predictive value of 18%, and a negative predictive value of 99.8% (95% confidence interval 13.78-19.18, p=0.0001). Conclusion: Pulse oximetry was found to be easy, safe, sensitive, and highly specific for diagnosis of CCHD.
12 CFR Appendix B to Part 222 - Model Notices of Furnishing Negative Information
Code of Federal Regulations, 2010 CFR
2018-01-01
... your credit report. Model Notice B-2 We have told a credit bureau about a late payment, missed payment... 12 Banks and Banking 3 2018-01-01 2018-01-01 false Model Notices of Furnishing Negative... Appendix B to Part 222—Model Notices of Furnishing Negative Information a. Although use of the model...
12 CFR Appendix B to Part 1022 - Model Notices of Furnishing Negative Information
Code of Federal Regulations, 2010 CFR
2018-01-01
... 12 Banks and Banking 8 2018-01-01 2018-01-01 false Model Notices of Furnishing Negative... REPORTING (REGULATION V) Pt. 1022, App. B Appendix B to Part 1022—Model Notices of Furnishing Negative Information a. Although use of the model notices is not required, a financial institution that is subject to...
9 CFR 85.8 - Interstate movement of swine from a qualified negative gene-altered vaccinated herd.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Interstate movement of swine from a... (INCLUDING POULTRY) AND ANIMAL PRODUCTS PSEUDORABIES § 85.8 Interstate movement of swine from a qualified negative gene-altered vaccinated herd. Swine from a qualified negative gene-altered vaccinated herd, and...
9 CFR 85.8 - Interstate movement of swine from a qualified negative gene-altered vaccinated herd.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Interstate movement of swine from a... (INCLUDING POULTRY) AND ANIMAL PRODUCTS PSEUDORABIES § 85.8 Interstate movement of swine from a qualified negative gene-altered vaccinated herd. Swine from a qualified negative gene-altered vaccinated herd, and...
9 CFR 85.8 - Interstate movement of swine from a qualified negative gene-altered vaccinated herd.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Interstate movement of swine from a... (INCLUDING POULTRY) AND ANIMAL PRODUCTS PSEUDORABIES § 85.8 Interstate movement of swine from a qualified negative gene-altered vaccinated herd. Swine from a qualified negative gene-altered vaccinated herd, and...
9 CFR 85.8 - Interstate movement of swine from a qualified negative gene-altered vaccinated herd.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Interstate movement of swine from a... (INCLUDING POULTRY) AND ANIMAL PRODUCTS PSEUDORABIES § 85.8 Interstate movement of swine from a qualified negative gene-altered vaccinated herd. Swine from a qualified negative gene-altered vaccinated herd, and...
Cheurfa, N; Giard, S
2015-01-01
Despite the standard management of non-palpable breast cancer (needle core biopsy diagnostic, accurate preoperative localization), there are differences in some cases between the malignant histo-pathological finding in diagnostic biopsy results and negative histo-pathological finding after surgical excision. The aim of this study is to evaluate this incidence and classifying them under three category: failure of surgical excision after preoperative identification; removal of the tumor was already completed by percutaneous biopsy; percutaneous biopsy true false positive. We conducted a study based on prospective database, all patients included in this study had partial mastectomy for ductal carcinoma in-situ or invasive cancer which was diagnosed by needle core biopsy and normal/benign after surgery. Regarding the partial mastectomy, 1863 was performed in the last three years in our center. Thirty-seven patients (2%) correspond our study criteria. After discussion of cases in our multidisciplinary reunion, 6 patients (16%) were considered as failure of surgical excision, 26 patients (70%) as true removal of the whole lesion in the core, and 5 patients (13%) as true false-positive cores. This is the first study witch investigate all factors that influence the results of negative final histo-pathological finding of surgical excision of the tumor after malignant diagnostic needle core biopsy. This rare situation need a multidisciplinary meeting to analyse all the steps of management and to determine causes of those false results and try to find adequate management to solve this problem. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Should bedside sonography be used first to diagnose pneumothorax secondary to blunt trauma?
Donmez, Halil; Tokmak, Turgut Tursem; Yildirim, Afra; Buyukoglan, Hakan; Ozturk, Mehmet; Yaşar Ayaz, Umit; Mavili, Ertugrul
2012-01-01
BACKGROUND.: Our purpose was to evaluate the effectiveness of bedside sonography (US) in the detection of pneumothorax secondary to blunt thoracic trauma. METHODS.: In this prospective study, 240 hemithoraces of 120 consecutive patients with multiple trauma were evaluated with chest radiographs (CXR) and bedside thoracic US for the diagnosis of pneumothorax. CT examinations were performed in 68 patients. Fifty-two patients who did not undergo CT examinations were excluded from the study. US examinations were performed independently at bedside by two radiologists who were not informed about CXR and CT findings. CXRs were interpreted by two radiologists who were unaware of the US and CT results. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CXR and US were calculated. RESULTS.: One hundred thirty-six hemithoraces were assessed in 68 patients. A total of 35 pneumothoraces were detected in 33 patients. On US, the diagnosis of pneumothorax was correct in 32 hemithoraces. In 98 hemithoraces without pneumothorax, US was normal. With US examination, there were three false-positive and three false-negative results. The sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of US were 91.4%, 97%, 91.4%, 97%, and 97%, respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CXR were 82.7%, 89.7%, 68.5%, 95%, and 89.5%, respectively. CONCLUSIONS.: Bedside thoracic US is an accurate method that can be used in trauma patients instead of CXR for the detection of pneumothorax. Copyright © 2012 Wiley Periodicals, Inc.
Laboratory and clinical evaluation of on-site urine drug testing.
Beck, Olof; Carlsson, Sten; Tusic, Marinela; Olsson, Robert; Franzen, Lisa; Hulten, Peter
2014-11-01
Products for on-site urine drug testing offer the possibility to perform screening for drugs of abuse directly at the point-of-care. This is a well-established routine in emergency and dependency clinics but further evaluation of performance is needed due to inherent limitations with the available products. Urine drug testing by an on-site product was compared with routine laboratory methods. First, on-site testing was performed at the laboratory in addition to the routine method. Second, the on-site testing was performed at a dependency clinic and urine samples were subsequently sent to the laboratory for additional analytical investigation. The on-site testing products did not perform with assigned cut-off levels. The subjective reading between the presence of a spot (i.e. negative test result) being present or no spot (positive result) was difficult in 3.2% of the cases, and occurred for all parameters. The tests performed more accurately in drug negative samples (specificity 96%) but less accurately for detecting positives (sensitivity 79%). Of all incorrect results by the on-site test the proportion of false negatives was 42%. The overall agreement between on-site and laboratory testing was 95% in the laboratory study and 98% in the clinical study. Although a high degree of agreement was observed between on-site and routine laboratory urine drug testing, the performance of on-site testing was not acceptable due to significant number of false negative results. The limited sensitivity of on-site testing compared to laboratory testing reduces the applicability of these tests.
Crompot, Emerence; Van Damme, Michael; Duvillier, Hugues; Pieters, Karlien; Vermeesch, Marjorie; Perez-Morga, David; Meuleman, Nathalie; Mineur, Philippe; Bron, Dominique; Lagneaux, Laurence; Stamatopoulos, Basile
2015-01-01
Microparticles (MPs), also called microvesicles (MVs) are plasma membrane-derived fragments with sizes ranging from 0.1 to 1μm. Characterization of these MPs is often performed by flow cytometry but there is no consensus on the appropriate negative control to use that can lead to false positive results. We analyzed MPs from platelets, B-cells, T-cells, NK-cells, monocytes, and chronic lymphocytic leukemia (CLL) B-cells. Cells were purified by positive magnetic-separation and cultured for 48h. Cells and MPs were characterized using the following monoclonal antibodies (CD19,20 for B-cells, CD3,8,5,27 for T-cells, CD16,56 for NK-cells, CD14,11c for monocytes, CD41,61 for platelets). Isolated MPs were stained with annexin-V-FITC and gated between 300nm and 900nm. The latex bead technique was then performed for easy detection of MPs. Samples were analyzed by Transmission (TEM) and Scanning Electron microscopy (SEM). Annexin-V positive events within a gate of 300-900nm were detected and defined as MPs. Our results confirmed that the characteristic antigens CD41/CD61 were found on platelet-derived-MPs validating our technique. However, for MPs derived from other cell types, we were unable to detect any antigen, although they were clearly expressed on the MP-producing cells in the contrary of several data published in the literature. Using the latex bead technique, we confirmed detection of CD41,61. However, the apparent expression of other antigens (already deemed positive in several studies) was determined to be false positive, indicated by negative controls (same labeling was used on MPs from different origins). We observed that mother cell antigens were not always detected on corresponding MPs by direct flow cytometry or latex bead cytometry. Our data highlighted that false positive results could be generated due to antibody aspecificity and that phenotypic characterization of MPs is a difficult field requiring the use of several negative controls.
Memarsadeghi, Mazda; Riedl, Christopher C; Kaneider, Andreas; Galid, Arik; Rudas, Margaretha; Matzek, Wolfgang; Helbich, Thomas H
2006-11-01
To prospectively assess the accuracy of nonenhanced versus ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance (MR) imaging for depiction of axillary lymph node metastases in patients with breast carcinoma, with histopathologic findings as reference standard. The study was approved by the university ethics committee; written informed consent was obtained. Twenty-two women (mean age, 60 years; range, 40-79 years) with breast carcinomas underwent nonenhanced and USPIO-enhanced (2.6 mg of iron per kilogram of body weight intravenously administered) transverse T1-weighted and transverse and sagittal T2-weighted and T2*-weighted MR imaging in adducted and elevated arm positions. Two experienced radiologists, blinded to the histopathologic findings, analyzed images of axillary lymph nodes with regard to size, morphologic features, and USPIO uptake. A third independent radiologist served as a tiebreaker if consensus between two readers could not be reached. Visual and quantitative analyses of MR images were performed. Sensitivity, specificity, and accuracy values were calculated. To assess the effect of USPIO after administration, signal-to-noise ratio (SNR) changes were statistically analyzed with repeated-measurements analysis of variance (mixed model) for MR sequences. At nonenhanced MR imaging, of 133 lymph nodes, six were rated as true-positive, 99 as true-negative, 23 as false-positive, and five as false-negative. At USPIO-enhanced MR imaging, 11 lymph nodes were rated as true-positive, 120 as true-negative, two as false-positive, and none as false-negative. In two metastatic lymph nodes in two patients with more than one metastatic lymph node, a consensus was not reached. USPIO-enhanced MR imaging revealed a node-by-node sensitivity, specificity, and accuracy of 100%, 98%, and 98%, respectively. At USPIO-enhanced MR imaging, no metastatic lymph nodes were missed on a patient-by-patient basis. Significant interactions indicating differences in the decrease of SNR values for metastatic and nonmetastatic lymph nodes were found for all sequences (P < .001 to P = .022). USPIO-enhanced MR imaging appears valuable for assessment of axillary lymph node metastases in patients with breast carcinomas and is superior to nonenhanced MR imaging.
Crompot, Emerence; Van Damme, Michael; Duvillier, Hugues; Pieters, Karlien; Vermeesch, Marjorie; Perez-Morga, David; Meuleman, Nathalie; Mineur, Philippe; Bron, Dominique; Lagneaux, Laurence; Stamatopoulos, Basile
2015-01-01
Background Microparticles (MPs), also called microvesicles (MVs) are plasma membrane-derived fragments with sizes ranging from 0.1 to 1μm. Characterization of these MPs is often performed by flow cytometry but there is no consensus on the appropriate negative control to use that can lead to false positive results. Materials and Methods We analyzed MPs from platelets, B-cells, T-cells, NK-cells, monocytes, and chronic lymphocytic leukemia (CLL) B-cells. Cells were purified by positive magnetic-separation and cultured for 48h. Cells and MPs were characterized using the following monoclonal antibodies (CD19,20 for B-cells, CD3,8,5,27 for T-cells, CD16,56 for NK-cells, CD14,11c for monocytes, CD41,61 for platelets). Isolated MPs were stained with annexin-V-FITC and gated between 300nm and 900nm. The latex bead technique was then performed for easy detection of MPs. Samples were analyzed by Transmission (TEM) and Scanning Electron microscopy (SEM). Results Annexin-V positive events within a gate of 300-900nm were detected and defined as MPs. Our results confirmed that the characteristic antigens CD41/CD61 were found on platelet-derived-MPs validating our technique. However, for MPs derived from other cell types, we were unable to detect any antigen, although they were clearly expressed on the MP-producing cells in the contrary of several data published in the literature. Using the latex bead technique, we confirmed detection of CD41,61. However, the apparent expression of other antigens (already deemed positive in several studies) was determined to be false positive, indicated by negative controls (same labeling was used on MPs from different origins). Conclusion We observed that mother cell antigens were not always detected on corresponding MPs by direct flow cytometry or latex bead cytometry. Our data highlighted that false positive results could be generated due to antibody aspecificity and that phenotypic characterization of MPs is a difficult field requiring the use of several negative controls. PMID:25978814
van der Wilden, Gwendolyn M; Van der Wilden, Gwen; Albers, Christoph E; Albers, Christof; Haefeli, Pascal C; Haefeli, Peter; Zimmermann, Heinz; Zimmerman, Heinz; Exadaktylos, Aristomenis; Exadaktylos, Aris; Levy, Phillip; Birkhan, Oscar; Birkham, Oscar; Michaildou, Maria; Michailidou, Maria; Sideris, Antonios; Velmahos, George C; Velmahos, George; Alam, Hasan B; Alam, Hasan; King, David R; King, David; Fagenholz, Peter J; Fagenholz, Peter; Yeh, D Dante; Yeh, Dante; de Moya, Marc A
2012-12-01
Pneumothoraces (PTXs) are a common entity in thoracic trauma. Micropower impulse radar (MIR) has been able to detect PTXs in surgical patients. However, this technology has not been tested previously on trauma patients. The purpose of this study was to determine the sensitivity and specificity of MIR to detect clinically significant PTXs. We hypothesized that MIR technology can effectively screen trauma patients for clinically significant PTXs. This was a prospective observational study in Level I trauma centers in Boston, Massachusetts, and Bern, Switzerland. All trauma patients undergoing a chest computed tomographic (CT) scan were eligible for the study. Consent was obtained, and readings were performed within 30 minutes before or after the CT scan. The patients had eight lung fields tested (four on each side). The qualitative and quantitative MIR results were blinded and stored on the device. We then compared the results of the MIR to the CT scan and the need for chest tube drainage. We defined PTXs as clinically significant if they required a chest tube. Seventy-five patients were enrolled, with a mean age of 46 ± 16 years. Eighty-four percent were male. The screening test took approximately 1 minute. All but two patients had blunt chest trauma. Six true-positives, 6 false-positives, 63 true-negatives, and 0 false-negatives resulted in an overall sensitivity of 100%. MIR is an easy to use handheld technology that effectively screened patients for clinically significant PTXs, with a sensitivity and negative predictive value of 100%. MIR may be used for rapid, repeatable, and ongoing surveillance of trauma patients. Diagnostic study, level III.
Hwang, Hamish; Marsh, Ian; Doyle, Jason
2014-01-01
Background Acute cholecystitis is one of the most common diseases requiring emergency surgery. Ultrasonography is an accurate test for cholelithiasis but has a high false-negative rate for acute cholecystitis. The Murphy sign and laboratory tests performed independently are also not particularly accurate. This study was designed to review the accuracy of ultrasonography for diagnosing acute cholecystitis in a regional hospital. Methods We studied all emergency cholecystectomies performed over a 1-year period. All imaging studies were reviewed by a single radiologist, and all pathology was reviewed by a single pathologist. The reviewers were blinded to each other’s results. Results A total of 107 patients required an emergency cholecystectomy in the study period; 83 of them underwent ultrasonography. Interradiologist agreement was 92% for ultrasonography. For cholelithiasis, ultrasonography had 100% sensitivity, 18% specificity, 81% positive predictive value (PPV) and 100% negative predictive value (NPV). For acute cholecystitis, it had 54% sensitivity, 81% specificity, 85% PPV and 47% NPV. All patients had chronic cholecystitis and 67% had acute cholecystitis on histology. When combined with positive Murphy sign and elevated neutrophil count, an ultrasound showing cholelithiasis or acute cholecystitis yielded a sensitivity of 74%, specificity of 62%, PPV of 80% and NPV of 53% for the diagnosis of acute cholecystitis. Conclusion Ultrasonography alone has a high rate of false-negative studies for acute cholecystitis. However, a higher rate of accurate diagnosis can be achieved using a triad of positive Murphy sign, elevated neutrophil count and an ultrasound showing cholelithiasis or cholecystitis. PMID:24869607
Dawson, D J; Khan, A N; Miller, V; Ratcliffe, J F; Shreeve, D R
1985-01-01
The distribution of radioactivity after the oral administration of sucralfate labelled with technetium-99m was studied in 33 patients with Crohn's disease (13 adults, 20 children), 10 with ulcerative colitis (four adults), and 29 controls (23 with upper intestinal disease, four irritable bowel, one hypolactasia, and one malrotation of the gut). Positive scans were obtained in all patients with ulcerative colitis and 29 of 31 with active Crohn's disease. The scans of two patients with inactive Crohn's disease were negative. There were two false negative scans in patients with Crohn's colitis and one false positive scan. Overall, sensitivity was 95% and specificity 97%. Comparison with radiology in 39 patients showed similar distribution of disease in 24 and more extensive disease in 12. The scan was inexpensive, simple to perform, well tolerated, allowed small and large bowel to be visualised simultaneously, and used a lower dose of radiation than barium studies. It may prove useful as a screening test for inflammatory bowel disease and in the serial assessment of disease activity. Images FIG 1 FIG 2 FIG 3 FIG 4 PMID:3933613
Improving Malaria Control in West Africa: Interruption of Transmission as a Paradigm Shift
Doumbia, Seydou O.; Ndiaye, Daouda; Koita, Ousmane A.; Diakité, Mahamadou; Nwakanma, Davis; Coulibaly, Mamadou; Traoré, Sekou F.; Keating, Joseph; Milner, Danny A.; Ndiaye, Jean-Louis; Sene, Papa Diogoye; Ahouidi, Ambroise; Dieye, Tandakha N.; Gaye, Oumar; Okebe, Joseph; Ceesay, Serign J.; Ngwa, Alfred; Oriero, Eniyou C.; Konaté, Lassana; Sy, Ngayo; Jawara, Musa; Faye, Ousmane; Kéita, Moussa; Cissé, Moussa; Sogoba, Nafomon; Poudiougou, Belco; Diawara, Sory; Sangaré, Lansana; Coulibaly, Tinzana; Seck, Ibrahima; Abubakar, Ismaela; Gomis, Jules; Mather, Frances J.; Sissako, Aliou; Diarra, Ayouba; Kandeh, Balla; Whalen, Christopher; Moyer, Brian; Nnedu, Obinna; Thiero, Oumar; Bei, Amy K.; Daniels, Rachel; Miura, Kazutoyo; Long, Carole A.; Fairhurst, Rick M.; Duraisingh, Manoj; Muskavitch, Marc A.T.; D’Alessandro, Umberto; Conway, David J.; Volkman, Sarah K.; Valim, Clarissa; Wirth, Dyann F.; Krogstad, Donald J.
2011-01-01
With the paradigm shift from the reduction of morbidity and mortality to the interruption of transmission, the focus of malaria control broadens from symptomatic infections in children ≤ 5 years of age to include asymptomatic infections in older children and adults. In addition, as control efforts intensify and the number of interventions increases, there will be decreases in prevalence, incidence and transmission with additional decreases in morbidity and mortality. Expected secondary consequences of these changes include upward shifts in the peak ages for infection (parasitemia) and disease, increases in the ages for acquisition of antiparasite humoral and cellular immune responses and increases in false-negative blood smears and rapid diagnostic tests. Strategies to monitor these changes must include: 1] studies of the entire population (that are not restricted to children ≤ 5 or ≤ 10 years of age), 2] study sites in both cities and rural areas (because of increasing urbanization across sub-Saharan Africa) and 3] innovative strategies for surveillance as the prevalence of infection decreases and the frequency of false-negative smears and rapid diagnostic tests increases. PMID:22142790
Saeed, Mohammad
2017-05-01
Systemic lupus erythematosus (SLE) is a complex disorder. Genetic association studies of complex disorders suffer from the following three major issues: phenotypic heterogeneity, false positive (type I error), and false negative (type II error) results. Hence, genes with low to moderate effects are missed in standard analyses, especially after statistical corrections. OASIS is a novel linkage disequilibrium clustering algorithm that can potentially address false positives and negatives in genome-wide association studies (GWAS) of complex disorders such as SLE. OASIS was applied to two SLE dbGAP GWAS datasets (6077 subjects; ∼0.75 million single-nucleotide polymorphisms). OASIS identified three known SLE genes viz. IFIH1, TNIP1, and CD44, not previously reported using these GWAS datasets. In addition, 22 novel loci for SLE were identified and the 5 SLE genes previously reported using these datasets were verified. OASIS methodology was validated using single-variant replication and gene-based analysis with GATES. This led to the verification of 60% of OASIS loci. New SLE genes that OASIS identified and were further verified include TNFAIP6, DNAJB3, TTF1, GRIN2B, MON2, LATS2, SNX6, RBFOX1, NCOA3, and CHAF1B. This study presents the OASIS algorithm, software, and the meta-analyses of two publicly available SLE GWAS datasets along with the novel SLE genes. Hence, OASIS is a novel linkage disequilibrium clustering method that can be universally applied to existing GWAS datasets for the identification of new genes.
Strålin, Kristoffer; Bäckman, Anders; Holmberg, Hans; Fredlund, Hans; Olcén, Per
2005-02-01
A multiplex PCR (mPCR) was developed for simultaneous detection of specific genes for Streptococcus pneumoniae (lytA), Mycoplasma pneumoniae (P1), Chlamydophila pneumoniae (ompA), and Haemophilus influenzae (16S rRNA, with verification PCR for P6). When the protocol was tested on 257 bacterial strains belonging to 37 different species, no false negatives and only one false positive were noted. One Streptococcus mitis out of thirty was positive for lytA. In a pilot application study of 81 sputum samples from different patients with suspected lower respiratory tract infection (LRTI), mPCR identified S. pneumoniae in 25 samples, H. influenzae in 29, M. pneumoniae in 3, and C. pneumoniae in 1. All samples culture positive for S. pneumoniae (n=15) and H. influenzae (n=15) were mPCR positive for the same bacteria. In a pilot control study with nasopharyngeal swabs and aspirates from 10 healthy adults, both culture and mPCR were negative. No PCR inhibition was found in any of the mPCR-negative sputum or nasopharyngeal samples. Whether all samples identified as positive by mPCR are truly positive in an aetiological perspective regarding LRTI remains to be evaluated in a well-defined patient material. In conclusion, the mPCR appears to be a promising tool in the aetiological diagnostics of LRTI.
Meiklejohn, D J; Ridley, L J; Ngu, M C; Cowlishaw, J L; Duller, A; Ridley, W
2018-06-11
Colorectal cancers result in substantial morbidity and mortality to Australian society each year. The usual investigation for bowel malignancyis optical colonoscopy (OC), withcomputed tomographic colonography (CTC) used as an alternative investigation. The catharsis and colon insufflation associated with these investigations pose a higher risk in the elderly and frail. Risks include perforation, serum electrolyte disturbance, and anaesthesia/sedation risks.Minimal preparation computed tomographic colonography (MPCTC) eliminates these risks. This paper audits a 6-year period ofMPCTC in an Australian tertiary referral hospital. 145 patients underwent MPCTC during the study period. There were 7 true positives, 2 false positives and 2 false negatives. Analysis of this population indicates a sensitivity of 0.78 (95% CI 0.51 - 1.05), specificity of 0.99 (95% CI 0.97 - 1.01), positive predictive value (PPV) of 0.78 (95% CI 0.51 - 1.05) and negative predictive value (NPV) of 0.99 (95% CI 0.97 - 1.01). These findings are concordant with other published studies. The auditconfirmsthatminimal preparation CT colonography is a reasonable alternative to OC and CTC in detecting colorectal cancer in symptomatic elderly and frail patients, without the procedural risks inherent inmore invasive investigations. For most patients MPCTC ruled out significant colorectal carcinoma with a high negative predictive value. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Iguchi, Hiroyoshi; Wada, Tadashi; Matsushita, Naoki; Oishi, Masahiro; Teranishi, Yuichi; Yamane, Hideo
2014-07-01
The accuracy and sensitivity of fine-needle aspiration cytology (FNAC) in this analysis were not satisfactory, and the false-negative rate seemed to be higher than for parotid tumours. The possibility of low-grade malignancy should be considered in the surgical treatment of accessory parotid gland (APG) tumours, even if the preoperative results of FNAC suggest that the tumour is benign. Little is known about the usefulness of FNAC in the preoperative evaluation of APG tumours, probably due to the paucity of APG tumour cases. We examined the usefulness of FNAC in the detection of malignant APG tumours. We conducted a retrospective analysis of 3 cases from our hospital, along with 18 previously reported Japanese cases. We compared the preoperative FNAC results with postoperative histopathological diagnoses of APG tumours and evaluated the accuracy, sensitivity, specificity and false-negative rates of FNAC in detecting malignant APG tumours. There were four false-negative cases (19.0%), three of mucoepidermoid carcinomas and one of malignant lymphoma. One false-positive result was noted in the case of a myoepithelioma, which was cytologically diagnosed as suspected adenoid cystic carcinoma. The accuracy, sensitivity and specificity of FNAC in detecting malignant tumours were 76.2%, 60.0% and 90.9%, respectively.
Argani, Pedram; Zhang, Lei; Reuter, Victor E; Tickoo, Satish K; Antonescu, Cristina R
2017-05-01
Xp11 translocation renal cell carcinoma (RCC) are defined by chromosome translocations involving the Xp11 breakpoint which results in one of a variety of TFE3 gene fusions. TFE3 break-apart florescence in situ hybridization (FISH) assays are generally preferred to TFE3 immunohistochemistry (IHC) as a means of confirming the diagnosis in archival material, as FISH is less sensitive to the variable fixation which can result in false positive or false negative IHC. Prompted by a case report in the cytogenetics literature, we identify 3 cases of Xp11 translocation RCC characterized by a subtle chromosomal inversion involving the short arm of the X chromosome, resulting in an RBM10-TFE3 gene fusion. TFE3 rearrangement was not detected by conventional TFE3 break-apart FISH, but was suggested by strong diffuse TFE3 immunoreactivity in a clean background. We then developed novel fosmid probes to detect the RBM10-TFE3 gene fusion in archival material. These cases validate RBM10-TFE3 as a recurrent gene fusion in Xp11 translocation RCC, illustrate a source of false-negative TFE3 break-apart FISH, and highlight the complementary role of TFE3 IHC and TFE3 FISH.
Robotic CCD microscope for enhanced crystal recognition
Segelke, Brent W.; Toppani, Dominique
2007-11-06
A robotic CCD microscope and procedures to automate crystal recognition. The robotic CCD microscope and procedures enables more accurate crystal recognition, leading to fewer false negative and fewer false positives, and enable detection of smaller crystals compared to other methods available today.
NASA Astrophysics Data System (ADS)
Park, So-Hyun; Lee, Dong-Soo; Lee, Yun-Hee; Lee, Seu-Ran; Kim, Min-Ju; Suh, Tae-Suk
2015-09-01
The aim of this work is to demonstrate both the physical and the biological quality assurance (QA) aspects as pretreatment QA of the head and neck (H&N) cancer plan for the volumetric modulated arc therapy (VMAT). Ten H&N plans were studied. The COMPASS® dosimetry analysis system and the tumor control probability (TCP) and the normal tissue complication probability (NTCP) calculation free program were used as the respective measurement and calculation tools. The reliability of these tools was verified by a benchmark study in accordance with the TG-166 report. For the physical component of QA, the gamma passing rates and the false negative cases between the calculated and the measured data were evaluated. The biological component of QA was performed based on the equivalent uniform dose (EUD), TCP and NTCP values. The evaluation was performed for the planning target volumes (PTVs) and the organs at risks (OARs), including the eyes, the lens, the parotid glands, the esophagus, the spinal cord, and the brainstem. All cases had gamma passing rates above 95% at an acceptance tolerance level with the 3%/3 mm criteria. In addition, the false negative instances were presented for the PTVs and OARs. The gamma passing rates exhibited a weak correlation with false negative cases. For the biological QA, the physical dose errors affect the EUD and the TCP for the PTVs, but no linear correlation existed between them. The EUD and NTCP for the OARs were shown the random differences that could not be attributed to the dose errors from the physical QA. The differences in the EUD and NTCP between the calculated and the measured results were mainly demonstrated for the parotid glands. This study describes the importance and the necessity of improved QA to accompany both the physical and the biological aspects for accurate radiation treatment.
van der Jagt, E.J.; van Westreenen, H.L.; van Dullemen, H.M.; Kappert, P.; Groen, H.; Sietsma, J.; Oudkerk, M.; Plukker, J.Th.M.; van Dam, G.M.
2009-01-01
Abstract Aim: In this feasibility study we investigated whether magnetic resonance imaging (MRI) with ultrasmall superparamagnetic iron oxide (USPIO) can be used to identify regional and distant lymph nodes, including mediastinal and celiac lymph node metastases in patients with oesophageal cancer. Patients and methods: Ten patients with a potentially curative resectable cancer of the oesophagus were eligible for this study. All patients included in the study had positive lymph nodes on conventional staging (including endoscopic ultrasound, computed tomography and fluorodeoxyglucose-positron emission tomography). Nine patients underwent MRI + USPIO before surgery. Results were restricted to those patients who had both MRI + USPIO and histological examination. Results were compared with conventional staging and histopathologic findings. Results: One patient was excluded due to expired study time. Five out of 9 patients underwent an exploration; in 1 patient prior to surgery MRI + USPIO diagnosed liver metastases and in 3 patients an oesophageal resection was performed. USPIO uptake in mediastinal lymph nodes was seen in 6 out of 9 patients; in 3 patients non-malignant nodes were not visible. In total, 9 lymph node stations (of 6 patients) were separately analysed; 7 lymph node stations were assessed as positive (N1) on MRI+USPIO compared with 9 by conventional staging. According to histology findings, there was one false-positive and one false-negative result in MRI + USPIO. Also, conventional staging modalities had one false-positive and one false-negative result. MRI + USPIO had surplus value in one patient. Not all lymph node stations could be compared due to unforeseen explorations. No adverse effects occurred after USPIO infusion. Conclusion: MRI+USPIO identified the majority of mediastinal and celiac (suspect) lymph nodes in 9 patients with oesophageal cancer. MRI+USPIO could have an additional value in loco-regional staging; however, more supplementary research is needed. PMID:19414293
Slapa, Rafal Z.; Piwowonski, Antoni; Jakubowski, Wieslaw S.; Bierca, Jacek; Szopinski, Kazimierz T.; Slowinska-Srzednicka, Jadwiga; Migda, Bartosz; Mlosek, R. Krzysztof
2012-01-01
Although elastography can enhance the differential diagnosis of thyroid nodules, its diagnostic performance is not ideal at present. Further improvements in the technique and creation of robust diagnostic criteria are necessary. The purpose of this study was to compare the usefulness of strain elastography and a new generation of elasticity imaging called supersonic shear wave elastography (SSWE) in differential evaluation of thyroid nodules. Six thyroid nodules in 4 patients were studied. SSWE yielded 1 true-positive and 5 true-negative results. Strain elastography yielded 5 false-positive results and 1 false-negative result. A novel finding appreciated with SSWE, were punctate foci of increased stiffness corresponding to microcalcifications in 4 nodules, some not visible on B-mode ultrasound, as opposed to soft, colloid-inspissated areas visible on B-mode ultrasound in 2 nodules. This preliminary paper indicates that SSWE may outperform strain elastography in differentiation of thyroid nodules with regard to their stiffness. SSWE showed the possibility of differentiation of high echogenic foci into microcalcifications and inspissated colloid, adding a new dimension to thyroid elastography. Further multicenter large-scale studies of thyroid nodules evaluating different elastographic methods are warranted. PMID:22685685
Negatively-Biased Credulity and the Cultural Evolution of Beliefs
Fessler, Daniel M. T.; Pisor, Anne C.; Navarrete, Carlos David
2014-01-01
The functions of cultural beliefs are often opaque to those who hold them. Accordingly, to benefit from cultural evolution’s ability to solve complex adaptive problems, learners must be credulous. However, credulity entails costs, including susceptibility to exploitation, and effort wasted due to false beliefs. One determinant of the optimal level of credulity is the ratio between the costs of two types of errors: erroneous incredulity (failing to believe information that is true) and erroneous credulity (believing information that is false). This ratio can be expected to be asymmetric when information concerns hazards, as the costs of erroneous incredulity will, on average, exceed the costs of erroneous credulity; no equivalent asymmetry characterizes information concerning benefits. Natural selection can therefore be expected to have crafted learners’ minds so as to be more credulous toward information concerning hazards. This negatively-biased credulity extends general negativity bias, the adaptive tendency for negative events to be more salient than positive events. Together, these biases constitute attractors that should shape cultural evolution via the aggregated effects of learners’ differential retention and transmission of information. In two studies in the U.S., we demonstrate the existence of negatively-biased credulity, and show that it is most pronounced in those who believe the world to be dangerous, individuals who may constitute important nodes in cultural transmission networks. We then document the predicted imbalance in cultural content using a sample of urban legends collected from the Internet and a sample of supernatural beliefs obtained from ethnographies of a representative collection of the world’s cultures, showing that beliefs about hazards predominate in both. PMID:24736596
Negatively-biased credulity and the cultural evolution of beliefs.
Fessler, Daniel M T; Pisor, Anne C; Navarrete, Carlos David
2014-01-01
The functions of cultural beliefs are often opaque to those who hold them. Accordingly, to benefit from cultural evolution's ability to solve complex adaptive problems, learners must be credulous. However, credulity entails costs, including susceptibility to exploitation, and effort wasted due to false beliefs. One determinant of the optimal level of credulity is the ratio between the costs of two types of errors: erroneous incredulity (failing to believe information that is true) and erroneous credulity (believing information that is false). This ratio can be expected to be asymmetric when information concerns hazards, as the costs of erroneous incredulity will, on average, exceed the costs of erroneous credulity; no equivalent asymmetry characterizes information concerning benefits. Natural selection can therefore be expected to have crafted learners' minds so as to be more credulous toward information concerning hazards. This negatively-biased credulity extends general negativity bias, the adaptive tendency for negative events to be more salient than positive events. Together, these biases constitute attractors that should shape cultural evolution via the aggregated effects of learners' differential retention and transmission of information. In two studies in the U.S., we demonstrate the existence of negatively-biased credulity, and show that it is most pronounced in those who believe the world to be dangerous, individuals who may constitute important nodes in cultural transmission networks. We then document the predicted imbalance in cultural content using a sample of urban legends collected from the Internet and a sample of supernatural beliefs obtained from ethnographies of a representative collection of the world's cultures, showing that beliefs about hazards predominate in both.
Enhanced HTS hit selection via a local hit rate analysis.
Posner, Bruce A; Xi, Hualin; Mills, James E J
2009-10-01
The postprocessing of high-throughput screening (HTS) results is complicated by the occurrence of false positives (inactive compounds misidentified as active by the primary screen) and false negatives (active compounds misidentified as inactive by the primary screen). An activity cutoff is frequently used to select "active" compounds from HTS data; however, this approach is insensitive to both false positives and false negatives. An alternative method that can minimize the occurrence of these artifacts will increase the efficiency of hit selection and therefore lead discovery. In this work, rather than merely using the activity of a given compound, we look at the presence and absence of activity among all compounds in its "chemical space neighborhood" to give a degree of confidence in its activity. We demonstrate that this local hit rate (LHR) analysis method outperforms hit selection based on ranking by primary screen activity values across ten diverse high throughput screens, spanning both cell-based and biochemical assay formats of varying biology and robustness. On average, the local hit rate analysis method was approximately 2.3-fold and approximately 1.3-fold more effective in identifying active compounds and active chemical series, respectively, than selection based on primary activity alone. Moreover, when applied to finding false negatives, this method was 2.3-fold better than ranking by primary activity alone. In most cases, novel hit series were identified that would have otherwise been missed. Additional uses of and observations regarding this HTS analysis approach are also discussed.
The Illusion of the Positive: The impact of natural and induced mood on older adults’ false recall
Emery, Lisa; Hess, Thomas M.; Elliot, Tonya
2012-01-01
Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults’ information processing and potentially increase underlying cognitive age differences. PMID:22292431
The illusion of the positive: the impact of natural and induced mood on older adults' false recall.
Emery, Lisa; Hess, Thomas M; Elliot, Tonya
2012-11-01
Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995 , Journal of Experimental Psychology: Learning, Memory, and Cognition, 21, 803) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults' information processing and potentially increase underlying cognitive age differences.
Antimicrobial peptide 99mTc-ubiquicidin 29-41 as human infection-imaging agent: clinical trial.
Akhtar, Muhammad Saeed; Qaisar, Aitzaz; Irfanullah, Javaid; Iqbal, Javaid; Khan, Bashar; Jehangir, Mustansar; Nadeem, Muhammad Afzal; Khan, Muhammad Aleem; Afzal, Muhammad Shahzad; Ul-Haq, Ikram; Imran, Muhammad Babar
2005-04-01
Ubiquicidin (UBI) 29-41 is a cationic, synthetic antimicrobial peptide fragment that binds preferentially with the anionic microbial cell membrane at the site of infection. The current study was conducted to evaluate its potential as an infection-imaging agent in humans. Eighteen patients, 9 female and 9 male (mean age, 31.7 y; range, 5-75 y), with suspected bone, soft-tissue, or prosthesis infections were included in the study. (99m)Tc-UBI 29-41 in a dose of 400 microg/370-400 MBq was injected intravenously in adults. A dynamic study was followed by spot views of the suspected region of infection (target) and a corresponding normal area (nontarget) at 30, 60, 120, and 240 min. The target-to-nontarget ratios were used to find the optimum time for imaging. Whole-body anterior and posterior images were also acquired at 30, 120, and 240 min to study biodistribution. Activity in each organ was expressed as percentage retained dose. Visual score (0-3) was used to categorize studies as positive or negative, with scores of 0 (minimal or no uptake; equivalent to soft tissue) and 1 (mild; less uptake than in liver) being considered negative and scores of 2 (moderate; uptake greater than or equal to that in liver) and 3 (intense; uptake greater than or equal to that in kidneys) being considered positive. Scans were interpreted as true- or false-positive and true- or false-negative on the basis of bacterial culture as the major criterion and the results of clinical tests, radiography, and 3-phase bone scanning as minor criteria. The biodistribution study showed a gradual decline in renal activity as percentage of administered dose from 6.53% +/- 0.58% at 30 min to 4.54% +/- 0.57% at 120 min and 3.38% +/- 0.55% at 240 min. The liver showed a similar trend, with values of 5.43% +/- 0.76%, 3.17% +/- 0.25%, and 2.02% +/- 0.30% at 30, 120, and 240 min, respectively. Radioactivity accumulated gradually in the urinary bladder, with values of 4.60% +/- 0.92% at 30 min, 23.00% +/- 2.32% at 120 min, and 38.85% +/- 4.01% at 240 min. Of 18 studies performed with 99mTc-UBI 29-41, 14 showed positive findings and 4 showed negative findings. Negative findings were subsequently confirmed to be true negative. The positive findings for 1 scan were interpreted as false positive, as no growth was obtained on bacterial culture and no evidence of infection was found on minor criteria. In 10 cases, the major criterion was used, whereas in 4 cases minor criteria had to be used for interpretation. Quantitative analysis revealed a maximum mean target-to-nontarget ratio of 2.75 +/- 1.69 at 30 min, which decreased to 2.04 +/- 1.01 at 120 min. The overall sensitivity, specificity, and accuracy were 100%, 80%, and 94.4%, respectively. No adverse reactions were observed during image acquisition and within 5 d after the study. 99mTc-UBI 29-41 showed promise in localizing foci of infection, with optimal visualization at 30 min.
Baker, Laura; Almadani, Ammar; Ball, Chad G
2015-07-15
The Focused Assessment with Sonography for Trauma examination is an invaluable tool in the initial assessment of any injured patient. Although highly sensitive and accurate for identifying hemoperitoneum, occasional false negative results do occur in select scenarios. We present a previously unreported case of survival following blunt cardiac rupture with associated negative pericardial window due to a concurrent pericardial wall laceration. A healthy 46-year-old white woman presented to our level 1 trauma center with hemodynamic instability following a motor vehicle collision. Although her abdominal Focused Assessment with Sonography for Trauma windows were positive for fluid, her pericardial window was negative. After immediate transfer to the operating room in the setting of persistent instability, a subsequent thoracotomy identified a blunt cardiac rupture that was draining into the ipsilateral pleural space via an adjacent tear in the pericardium. The cardiac injury was controlled with digital pressure, resuscitation completed, and then repaired using standard cardiorrhaphy techniques. Following repair of her injuries (left ventricle, left atrial appendage, and liver), her postoperative course was uneventful. Evaluation of the pericardial space using Focused Assessment with Sonography for Trauma is an important component in the initial assessment of the severely injured patient. Even in cases of blunt mechanisms however, clinicians must be wary of occasional false negative pericardial ultrasound evaluations secondary to a concomitant pericardial laceration and subsequent decompression of hemorrhage from the cardiac rupture into the ipsilateral pleural space.
False HDAC Inhibition by Aurone Compound.
Itoh, Yukihiro; Suzuki, Miki; Matsui, Taiji; Ota, Yosuke; Hui, Zi; Tsubaki, Kazunori; Suzuki, Takayoshi
2016-01-01
Fluorescence assays are useful tools for estimating enzymatic activity. Their simplicity and manageability make them suitable for screening enzyme inhibitors in drug discovery studies. However, researchers need to pay attention to compounds that show auto-fluorescence and quench fluorescence, because such compounds lower the accuracy of the fluorescence assay systems by producing false-positive or negative results. In this study, we found that aurone compound 7, which has been reported as a histone deacetylase (HDAC) inhibitor, gave false-positive results. Although compound 7 was identified by an in vitro HDAC fluorescence assay, it did not show HDAC inhibitory activity in a cell-based assay, leading us to suspect its in vitro HDAC inhibitory activity. As a result of verification experiments, we found that compound 7 interferes with the HDAC fluorescence assay by quenching the HDAC fluorescence signal. Our findings underscore the faults of fluorescence assays and call attention to careless interpretation.
Estimated number of infants detected and missed by critical congenital heart defect screening.
Ailes, Elizabeth C; Gilboa, Suzanne M; Honein, Margaret A; Oster, Matthew E
2015-06-01
In 2011, the US Secretary of Health and Human Services recommended universal screening of newborns for critical congenital heart defects (CCHDs), yet few estimates of the number of infants with CCHDs likely to be detected through universal screening exist. Our objective was to estimate the number of infants with nonsyndromic CCHDs in the United States likely to be detected (true positives) and missed (false negatives) through universal newborn CCHD screening. We developed a simulation model based on estimates of birth prevalence, prenatal diagnosis, late detection, and sensitivity of newborn CCHD screening through pulse oximetry to estimate the number of true-positive and false-negative nonsyndromic cases of the 7 primary and 5 secondary CCHD screening targets identified through screening. We estimated that 875 (95% uncertainty interval [UI]: 705-1060) US infants with nonsyndromic CCHDs, including 470 (95% UI: 360-585) infants with primary CCHD screening targets, will be detected annually through newborn CCHD screening. An additional 880 (UI: 700-1080) false-negative screenings, including 280 (95% UI: 195-385) among primary screening targets, are expected. We estimated that similar numbers of CCHDs would be detected under scenarios comparing "lower" (∼19%) and "higher" (∼41%) than current prenatal detection prevalences. A substantial number of nonsyndromic CCHD cases are likely to be detected through universal CCHD screening; however, an equal number of false-negative screenings, primarily among secondary targets of screening, are likely to occur. Future efforts should document the true impact of CCHD screening in practice. Copyright © 2015 by the American Academy of Pediatrics.
Prenatal Genetic Screening Tests
... information about the rates of false-positive and false-negative results for each test. What should I consider when deciding whether to have prenatal genetic testing? It is your choice whether to have prenatal testing. Your personal beliefs and values are important factors in the decision ...
The dissociable effects of stereotype threat on older adults’ memory encoding and retrieval
Krendl, Anne C.; Ambady, Nalini; Kensinger, Elizabeth A.
2015-01-01
The present study asks how subliminal exposure to negative stereotypes about age-related memory deficits affects older adults’ memory performance. Whereas prior research has focused on the effect of “stereotype threat” on older adults’ memory for neutral material, the present study additionally examines the effect on memory for positive and negative words, as well as whether the subliminal “threat” has a larger impact on memory performance when it occurs prior to encoding or prior to retrieval (as compared to a control condition). Results revealed that older adults’ memory impairments were most pronounced when the threat was placed prior to retrieval as compared to when the threat was placed prior to encoding or no threat occurred. Moreover, the threat specifically increased false memory rates, particularly for neutral items compared to positive and negative ones. These results emphasize that stereotype threat effects vary depending upon the phase of memory it impacts. PMID:26029498
Matsuda, Chikashi; Moriyama, Hidehiko; Taketani, Takeshi; Shibata, Hiroshi; Nagai, Atsushi
2011-01-01
The presence in serum of the Hepatitis B surface antigen (HBsAg), the outer envelope of the hepatitis B virus (HBV), indicates viral infection, used in laboratory tests to confirm this. We report a case of discrepancy among HBsAg test results detected between measurements in a subject with HB infection. Gene analysis demonstrated several S region gene mutations, not detected previously. We tested 12 measurements e.g., EIA, CLIA, CLEIA, F-EIA, MAT, and IC for whether they could detect our subject's HBsAg and found that it was not recognized by a method using only a single monoclonal antibody to detect HBsAg in two detection processes, in contrast to the 11 other measurements, which used two different antibodies. This case shows that amino acid substitution may cause a false negative result for HBsAg. Gene mutations known to occur in HBV, should thus trigger an awareness of the need to keep in mind that false negative results can happen in case such as ours.
Satz, Alexander L; Hochstrasser, Remo; Petersen, Ann C
2017-04-10
To optimize future DNA-encoded library design, we have attempted to quantify the library size at which the signal becomes undetectable. To accomplish this we (i) have calculated that percent yields of individual library members following a screen range from 0.002 to 1%, (ii) extrapolated that ∼1 million copies per library member are required at the outset of a screen, and (iii) from this extrapolation predict that false negative rates will begin to outweigh the benefit of increased diversity at library sizes >10 8 . The above analysis is based upon a large internal data set comprising multiple screens, targets, and libraries; we also augmented our internal data with all currently available literature data. In theory, high false negative rates may be overcome by employing larger amounts of library; however, we argue that using more than currently reported amounts of library (≫10 nmoles) is impractical. The above conclusions may be generally applicable to other DNA encoded library platforms, particularly those platforms that do not allow for library amplification.
Risk of Breast Cancer in Women with False-Positive Results according to Mammographic Features.
Castells, Xavier; Torá-Rocamora, Isabel; Posso, Margarita; Román, Marta; Vernet-Tomas, Maria; Rodríguez-Arana, Ana; Domingo, Laia; Vidal, Carmen; Baré, Marisa; Ferrer, Joana; Quintana, María Jesús; Sánchez, Mar; Natal, Carmen; Espinàs, Josep A; Saladié, Francina; Sala, María
2016-08-01
Purpose To assess the risk of breast cancer in women with false-positive screening results according to radiologic classification of mammographic features. Materials and Methods Review board approval was obtained, with waiver of informed consent. This retrospective cohort study included 521 200 women aged 50-69 years who underwent screening as part of the Spanish Breast Cancer Screening Program between 1994 and 2010 and who were observed until December 2012. Cox proportional hazards regression analysis was used to estimate the age-adjusted hazard ratio (HR) of breast cancer and the 95% confidence interval (CI) in women with false-positive mammograms as compared with women with negative mammograms. Separate models were adjusted for screen-detected and interval cancers and for screen-film and digital mammography. Time without a breast cancer diagnosis was plotted by using Kaplan-Meier curves. Results When compared with women with negative mammograms, the age-adjusted HR of cancer in women with false-positive results was 1.84 (95% CI: 1.73, 1.95; P < .001). The risk was higher in women who had calcifications, whether they were (HR, 2.73; 95% CI: 2.28, 3.28; P < .001) or were not (HR, 2.24; 95% CI: 2.02, 2.48; P < .001) associated with masses. Women in whom mammographic features showed changes in subsequent false-positive results were those who had the highest risk (HR, 9.13; 95% CI: 8.28, 10.07; P < .001). Conclusion Women with false-positive results had an increased risk of breast cancer, particularly women who had calcifications at mammography. Women who had more than one examination with false-positive findings and in whom the mammographic features changed over time had a highly increased risk of breast cancer. Previous mammographic features might yield useful information for further risk-prediction models and personalized follow-up screening protocols. (©) RSNA, 2016 Online supplemental material is available for this article.
Cameirão, Mónica S; Faria, Ana Lúcia; Paulino, Teresa; Alves, Júlio; Bermúdez I Badia, Sergi
2016-08-09
Virtual Reality (VR) based methods for stroke rehabilitation have mainly focused on motor rehabilitation, but there is increasing interest in integrating motor and cognitive training to increase similarity to real-world settings. Unfortunately, more research is needed for the definition of which type of content should be used in the design of these tools. One possibility is the use of emotional stimuli, which are known to enhance attentional processes. According to the Socioemotional Selectivity Theory, as people age, the emotional salience arises for positive and neutral, but not for negative stimuli. For this study we developed a cognitive-motor VR task involving attention and short-term memory, and we investigated the impact of using emotional images of varying valence. The task consisted of finding a target image, shown for only two seconds, among fourteen neutral distractors, and selecting it through arm movements. After performing the VR task, a recall task took place and the patients had to identify the target images among a valence-matched number of distractors. Ten stroke patients participated in a within-subjects experiment with three conditions based on the valence of the images: positive, negative and neutral. Eye movements were recorded during VR task performance with an eye tracking system. Our results show decreased attention for negative stimuli in the VR task performance when compared to neutral stimuli. The recall task shows significantly more wrongly identified images (false memories) for negative stimuli than for neutral. Regression and correlation analyses with the Montreal Cognitive Assessment and the Geriatric Depression Scale revealed differential effects of cognitive function and depressive symptomatology in the encoding and recall of positive, negative and neutral images. Further, eye movement data shows reduced search patterns for wrongly selected stimuli containing emotional content. The results of this study suggest that it is feasible to use emotional content in a VR based cognitive-motor task for attention and memory training after stroke. Stroke survivors showed less attention towards negative information, exhibiting reduced visual search patterns and more false memories. We have also shown that the use of emotional stimuli in a VR task can provide additional information regarding patient's mood and cognitive status.
Onoue, Satomi; Suzuki, Gen; Kato, Masashi; Hirota, Morihiko; Nishida, Hayato; Kitagaki, Masato; Kouzuki, Hirokazu; Yamada, Shizuo
2013-12-01
The main purpose of the present study was to establish a non-animal photosafety assessment approach for cosmetics using in vitro photochemical and photobiochemical screening systems. Fifty-one cosmetics, pharmaceutics and other chemicals were selected as model chemicals on the basis of animal and/or clinical photosafety information. The model chemicals were assessed in terms of photochemical properties by UV/VIS spectral analysis, reactive oxygen species (ROS) assay and 3T3 neutral red uptake phototoxicity testing (3T3 NRU PT). Most phototoxins exhibited potent UV/VIS absorption with molar extinction coefficients of over 1000M(-1)cm(-1), although false-negative prediction occurred for 2 cosmetic phototoxins owing to weak UV/VIS absorption. Among all the cosmetic ingredients, ca. 42% of tested chemicals were non-testable in the ROS assay because of low water solubility; thereby, micellar ROS (mROS) assay using a solubilizing surfactant was employed for follow-up screening. Upon combination use of ROS and mROS assays, the individual specificity was 88.2%, and the positive and negative predictivities were estimated to be 94.4% and 100%, respectively. In the 3T3 NRU PT, 3 cosmetics and 4 drugs were incorrectly predicted not to be phototoxic, although some of them were typical photoallergens. Thus, these in vitro screening systems individually provide false predictions; however, a systematic tiered approach using these assays could provide reliable photosafety assessment without any false-negatives. The combined use of in vitro assays might enable simple and fast non-animal photosafety evaluation of cosmetic ingredients. Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stattaus, Joerg, E-mail: joerg.stattaus@uni-due.de; Kuehl, Hilmar; Ladd, Susanne
2007-09-15
Purpose. Our study aimed to determine the visibility of small liver lesions during CT-guided biopsy and to assess the influence of lesion visibility on biopsy results. Material and Methods. Fifty patients underwent CT-guided core biopsy of small focal liver lesions (maximum diameter, 3 cm); 38 biopsies were performed using noncontrast CT, and the remaining 12 were contrast-enhanced. Visibility of all lesions was graded on a 4-point-scale (0 = not visible, 1 = poorly visible, 2 = sufficiently visible, 3 = excellently visible) before and during biopsy (with the needle placed adjacent to and within the target lesion). Results. Forty-three biopsiesmore » (86%) yielded diagnostic results, and seven biopsies were false-negative. In noncontrast biopsies, the rate of insufficiently visualized lesions (grades 0-1) increased significantly during the procedure, from 10.5% to 44.7%, due to needle artifacts. This resulted in more (17.6%) false-negative biopsy results compared to lesions with good visualization (4.8%), although this difference lacks statistical significance. Visualization impairment appeared more often with an intercostal or subcostal vs. an epigastric access and with a subcapsular vs. a central lesion location, respectively. With contrast-enhanced biopsy the visibility of hepatic lesions was only temporarily improved, with a risk of complete obscuration in the late phase. Conclusion. In conclusion, visibility of small liver lesions diminished significantly during CT-guided biopsy due to needle artifacts, with a fourfold increased rate of insufficiently visualized lesions and of false-negative histological results. Contrast enhancement did not reveal better results.« less
[Abnormalities in cervical smears stored in plastic bags: potential cause of false negatives].
Ortega-González, Patricia; González-Bravo, Margarita S; Jiménez-Muñoz-Ledo, Gustavo; Macías, Alejandro E
2011-01-01
Cervical smear is the most economic and efficient diagnostic tool for the screening of cervical cancer. However, since plastic bags have been used in Guanajuato to transport and store smears, we have observed cytological abnormalities which difficult the diagnosis and lead to false negatives. To describe those abnormalities. Out of 340 women registered in a primary care center in Mexico, 68 were selected through systematic random sampling during 2007. A cervical smear was obtained and placed on two slides. The first sample was allowed to dry but the second one was placed into the plastic bag immediately after fixation. After 15 days all the smears were stained with the Papanicolaou technique. A certified pathologist, blinded about the variable of study, interpreted the samples according to the Bethesda system, and evaluated the presence of necrosis, edema, holes, and opportunistic microorganisms. Of the 68 smears exposed to a humid storage, 36 (53%) were inadequate for diagnosis (Fisher's exact probability < 0.001). From them, 36 (53%) had holes or lagoons, 34 (50%) had edema, 31 (46%) had necrosis, and 15 (22%) had fungus. On the other hand, the 68 dried cervical smears were all adequate for diagnosis and none had the changes or cytological abnormalities. The humid transport and storage of cervical smears produced abnormalities in the normal morphology that could lead to false negative results. The guideline for the handling of cervical smears must stress the importance of allowing the smears to dry completely after fixation and before storing them in plastic bags.
Xue, Jiao-Mei; Lin, Ping-Zhen; Sun, Ji-Wei; Cao, Feng-Lin
2017-12-01
Here, we explored the functional and neural mechanisms underlying aggression related to adverse childhood experiences. We assessed behavioral performance and event-related potentials during a go/no-go and N-back paradigm. The participants were 15 individuals with adverse childhood experiences and high aggression (ACE + HA), 13 individuals with high aggression (HA), and 14 individuals with low aggression and no adverse childhood experiences (control group). The P2 latency (initial perceptual processing) was longer in the ACE + HA group for the go trials. The HA group had a larger N2 (response inhibition) than controls for the no-go trials. Error-related negativity (error processing) in the ACE + HA and HA groups was smaller than that of controls for false alarm go trials. Lastly, the ACE + HA group had shorter error-related negativity latencies than controls for false alarm trials. Overall, our results reveal the neural correlates of executive function in aggressive individuals with ACEs.
Ramirez-Arcos, Sandra; DiFranco, Caesar; McIntyre, Terri; Goldman, Mindy
2017-09-01
Canadian Blood Services screens 100% of platelet concentrates (PCs) for bacterial contamination with the BacT/ALERT system. Quality-control sterility testing of 1% (≥10 units) of outdated PCs is performed monthly. Data from routine screening, quality-control testing, and septic reactions obtained from 2010 to 2016 are presented herein. In total, 601,988 buffy coat PC pools and 186,737 apheresis PCs were routinely screened with aerobic cultures over 6 years. Outdate quality-control testing of 8535 buffy coat and 8498 apheresis PCs was performed using aerobic and anaerobic cultures during the same period. Results were classified as "true-positives" when the same bacterium was isolated in initial and confirmatory cultures or "false-negatives" when bacteria were missed in early screening and were captured during quality-control sterility testing or through investigation of sepsis cases. During routine screening, the true-positive rates between buffy coat (0.94 per 10,000) and apheresis (0.96 per 10,000) PCs were similar (p = 0.9473). Seventy-five bacteria isolated during PC screening included Gram-positive and Gram-negative organisms. Six false-negative septic reactions were reported that implicated coagulase-negative staphylococci (n = 3) and Staphylococcus aureus (n = 3) for approximate rates of 1 per 100,000 transfusion reactions and 1 per 500,000 fatalities. During quality-control testing, the false-negative rates between buffy coat (8 per 10,000) and apheresis (9 per 10,000) PCs were similar (p = 0.7897). All 15 quality-control isolates were Gram-positive bacteria. The current bacterial screening protocol is efficacious for identifying Gram-negative bacteria. However, the high proportion of Gram-positive organisms detected on outdate quality-control testing and septic transfusion events demonstrates a residual safety risk that merits further intervention. © 2017 AABB.
Mundangepfupfu, Tichaendepi; Waseem, Muhammad
2014-03-01
Hydatidiform mole (molar pregnancy) is a benign tumor of placental trophoblastic cells, which release human chorionic gonadotropin (hCG). Several case reports have described complete hydatidiform moles with false-negative urine qualitative hCG tests. These negative pregnancy tests have been attributed to the hook effect. We report an unusual presentation of a partial mole and review an alternative explanation for the negative hCG test. As partial moles are usually not associated with a large proliferation of trophoblastic cells, levels of hCG are commonly < 100,000 mIU/mL. The most common presentation of a hydatidiform mole is vaginal bleeding. Hydatidiform mole is associated with a risk of malignant transformation and disseminated disease. In a pregnant patient, vaginal bleeding and abdominal pain are common presentations. Molar pregnancy is an uncommon cause of abdominal pain and vaginal bleeding that should be considered. A 47-year-old female presented to the emergency department with abdominal pain and vaginal bleeding. Urine qualitative hCG was negative and serum quantitative hCG was 1,094,950 mIU/mL. Pelvic ultrasonography showed a uterine cavity containing a soft-tissue mass with multiple cystic lesions and the hydatidiform mole was extracted with suction curettage. Tissue pathology confirmed partial hydatidiform mole. In addition to the hook effect, we present another possible explanation for the false-negative test; namely the inability of some assays to detect hCG-degradation products, which may be higher in clinical samples from patients with hydatidiform mole. This case underscores the importance of knowing the limitations of the commonly used hCG assays. Copyright © 2014 Elsevier Inc. All rights reserved.
Weaver, Lindell K; Churchill, Susan K; Deru, Kayla; Cooney, Darryl
2013-02-01
Symptoms of carbon monoxide (CO) poisoning are non-specific. Diagnosis requires suspicion of exposure, confirmed by measuring ambient CO levels or carboxyhemoglobin (COHb). An FDA-approved pulse oximeter (Rad-57) can measure CO saturation (S(pCO)). The device accuracy has implications for clinical decision-making. From April 1 to August 15, 2008, study personnel measured S(pCO) and documented demographic factors at time of clinical blood draw, in a convenience sample of 1,363 subjects presenting to the emergency department at Intermountain Medical Center, Murray, Utah. The technician then assayed COHb. COHb and S(pCO) values were compared by subject; false positive or negative values were defined as S(pCO) at least 3 percentage points greater or less than COHb level, reported by the manufacturer to be ± 1 SD in performance. In 1,363 subjects, 613 (45%) were male, 1,141 (84%) were light-skinned, 14 in shock, 4 with CO poisoning, and 122 (9%) met the criteria for a false positive value (range 3-19 percentage points), while 247 (18%) met the criteria for a false negative value (-13 to -3 percentage points). Risks for a false positive S(pCO) reading included being female and having a lower perfusion index. Methemoglobin, body temperature, and blood pressure also appear to influence the S(pCO) accuracy. There was variability among monitors, possibly related to technician technique, as rotation of monitors among technicians was not enforced. While the Rad-57 pulse oximeter functioned within the manufacturer's specifications, clinicians using the Rad-57 should expect some S(pCO) readings to be significantly higher or lower than COHb measurements, and should not use S(pCO) to direct triage or patient management. An elevated S(pCO) could broaden the diagnosis of CO poisoning in patients with non-specific symptoms. However, a negative S(pCO) level in patients suspected of having CO poisoning should never rule out CO poisoning, and should always be confirmed by COHb. © 2013 Daedalus Enterprises.
Borgstein, P J; Gordijn, R V; Eijsbouts, Q A; Cuesta, M A
1997-09-01
The aggressive surgical approach to patients suspected of having acute appendicitis for fear of perforation, and the inaccuracy of available diagnostic methods lead to an unacceptably high negative appendicectomy rate, especially in young women, in whom gynecological disorders frequently mimic appendicitis. Our objectives were to determine the value of diagnostic laparoscopy in women of child-bearing age to reduce the number of negative laparotomies and establish the correct diagnosis to allow prompt and appropriate treatment. 161 consecutive adult female patients under 50 years of age with a clinical diagnosis of acute appendicitis underwent diagnostic laparoscopy prior to the planned appendicectomy. If an inflamed appendix was found, appendicectomy was usually done through a muscle-splitting McBurney incision. Other diagnoses were treated accordingly. A normal appendix was not removed. Results were compared to a group of 42 similar patients in whom the laparoscopy was omitted for various reasons, to 23 postmenopausal women, and to all 137 male adults, directly operated by the McBurney approach. After laparoscopy, 55% of the patients required appendicectomy for appendicitis while in 23% a gynecological diagnosis was made in spite of previous examination by a gynecologist. Fourteen percent had a negative laparoscopy. There were no false-negative results. The negative appendicectomy rate after laparoscopy was 5% due to two false positives and eight laparoscopy failures. In the group of fertile females who escaped laparoscopy the negative appendicectomy rate was 38%. The respective rates for postmenopausal women and men were 4% and 8%. All women of child-bearing age suspected of having acute appendicitis should undergo diagnostic laparoscopy prior to the planned appendicectomy, regardless of the certainty of the preoperative diagnosis. This is currently the only way to reduce the negative appendicectomy rate and establish a correct diagnosis allowing prompt and appropriate treatment. In male patients and postmenopausal women one may proceed directly to emergency appendicectomy.
Nakhoul, Georges N; Hickner, John
2013-06-01
Rapid antigen detection tests (RADT) are commonly used to guide appropriate antibiotic treatment of group A beta-hemolytic streptococcal (GABHS) pharyngitis. In adults, there is controversy about the need for routine backup testing of negative RADT. Estimate the costs and benefits in adults of routine backup testing by DNA Gen-probe of negative RADT (Acceava). Observational follow-up study. All patients aged 18 years and older visiting a Cleveland Clinic generalist physician in 2009 and 2010 with a visit diagnosis of acute pharyngitis (ICD codes 462, 034.0). The patients were identified using the Cleveland Clinic Epic Clarity database. We determined the proportion of false negative RADT, antibiotic prescription patterns and rate of serious suppurative complications within 30 days of the office visit. Of 25,130 patients with acute pharyngitis, 19% had no testing and 81% were tested. Of the 15,555 patients that had a negative RADT and follow-up DNA probe, 6% had a positive DNA probe. Of the 953 patients who had a negative RADT and a positive DNA strep probe, 48% received an antibiotic prescription at the time of the visit and 51% received an antibiotic prescription after an average of 2.3 days. Only one patient with a negative RADT and no follow-up DNA probe developed a peritonsillar abscess. Overall, of the 15,555 DNA probes performed, management was altered in only 3% of the patients at a total cost of $1,757,715. Fifty-six percent received an antibiotic while only 19.5% had a confirmed strep throat diagnosis. The false negative rate of Acceava RADT for the diagnosis of GABHS pharyngitis was 6%. We question the benefit of routine DNA probe backup testing in adults because of its substantial cost, an average delay in antibiotic prescribing of over 2 days, and because suppurative complications are very uncommon. We found a high rate of inappropriate antibiotic prescribing.
False-positive cryptococcal antigen latex agglutination caused by disinfectants and soaps.
Blevins, L B; Fenn, J; Segal, H; Newcomb-Gayman, P; Carroll, K C
1995-01-01
Five disinfectants or soaps were tested to determine if any could be responsible for false-positive results obtained with the Latex-Crypto Antigen Detection System kit (Immuno-Mycologics, Inc., Norman, Okla.). Three disinfectants or soaps (Derma soap, 7X, and Bacdown) produced false-positive agglutination after repeated washing of ring slides during testing of a known negative cerebrospinal fluid specimen. PMID:7650214
Yamamoto, Maki; Fisher, Kate J; Wong, Joyce Y; Koscso, Jonathan M; Konstantinovic, Monique A; Govsyeyev, Nicholas; Messina, Jane L; Sarnaik, Amod A; Cruse, C Wayne; Gonzalez, Ricardo J; Sondak, Vernon K; Zager, Jonathan S
2015-05-15
Sentinel lymph node biopsy (SLNB) is indicated for the staging of clinically lymph node-negative melanoma of intermediate thickness, but its use is controversial in patients with thick melanoma. From 2002 to 2012, patients with melanoma measuring ≥4 mm in thickness were evaluated at a single institution. Associations between survival and clinicopathologic characteristics were explored. Of 571 patients with melanomas measuring ≥4 mm in thickness and no distant metastases, the median age was 66 years and 401 patients (70.2%) were male. The median Breslow thickness was 6.2 mm; the predominant subtype was nodular (45.4%). SLNB was performed in 412 patients (72%) whereas 46 patients (8.1%) presented with clinically lymph node-positive disease and 113 patients (20%) did not undergo SLNB. A positive SLN was found in 161 of 412 patients (39.1%). For SLNB performed at the study institution, 14 patients with a negative SLNB developed disease recurrence in the mapped lymph node basin (false-negative rate, 12.3%). The median disease-specific survival (DSS), overall survival (OS), and recurrence-free survival (RFS) for the entire cohort were 62.1 months, 42.5 months, and 21.2 months, respectively. The DSS and OS for patients with a negative SLNB were 82.4 months and 53.4 months, respectively; 41.2 months and 34.7 months, respectively, for patients with positive SLNB; and 26.8 months and 22 months, respectively, for patients with clinically lymph node-positive disease (P<.0001). The median RFS was 32.4 months for patients who were SLNB negative, 14.3 months for patients who were SLNB positive, and 6.8 months for patients with clinically lymph node-positive disease (P<.0001). With an acceptably low false-negative rate, patients with thick melanoma and a negative SLNB appear to have significantly prolonged RFS, DSS, and OS compared with those with a positive SLNB. Therefore, SLNB should be considered as indicated for patients with thick, clinically lymph node-negative melanoma. © 2015 American Cancer Society.
Goodman, Gail S.; Ogle, Christin M.; Block, Stephanie D.; Harris, LaTonya S.; Larson, Rakel P.; Augusti, Else-Marie; Cho, Young Il; Beber, Jonathan; Timmer, Susan; Urquiza, Anthony
2014-01-01
The purpose of the present research was to examine Deese-Roediger-McDermott (DRM) false memory for trauma-related and nontrauma-related lists in adolescents and adults with and without documented histories of child sexual abuse (CSA). Individual differences in psychopathology and adult attachment were also explored. Participants were administered free recall and recognition tests after hearing CSA, negative, neutral, and positive DRM lists. In free recall, CSA and negative lists produced the most false memory. In sharp contrast, for recognition, CSA lists enjoyed the highest d’ scores. CSA-group adolescents who evinced greater PTSD symptoms had higher rates of false memory compared to: 1) nonCSA-group adolescents with higher PTSD symptom scores (free recall), and 2) CSA-group adolescents with lower PTSD symptom scores (recognition). Regression analyses revealed that individuals with higher PTSD scores and greater fearful-avoidant attachment tendencies showed less proficient memory monitoring for CSA lists. Implications for trauma and memory development and for translational research are discussed. PMID:23786687
Sager, Sait; Kabasakal, Levent; Halac, Metin; Maecke, Helmut; Uslu, Lebriz; Önsel, Çetin; Kanmaz, Bedii
2013-05-01
There have been various studies for early diagnosis of local recurrent or distant metastatic thyroid cancers. The aim of this study is to evaluate the clinical utility of 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE, octreotide derivatives, to detect recurrences or distant metastases in 131I-negative thyroglobulin positive thyroid cancer patients and to compare the lesions with FDG PET and 99mTc-MIBI studies in the same patient group. Twenty differentiated thyroid cancer patients, 7 male and 13 female, mean age 54.6 ± 15.3 (range 13-78 years), were included in this study. Eighteen patients had papillary thyroid cancer and 2 had follicular thyroid cancer. Fifteen patients received HYNIC-TOC and 5 patients received HYNIC-TATE as a radiopharmaceutical. All patients underwent whole-body scan 1 and 4 hours after injection of octreotide derivatives and SPECT imagings were performed from the suspicious sites. The lesions that were seen in 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE studies were compared with 99mTc-MIBI and FDG-PET studies. Among 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE scintigraphies, 15 patient studies were evaluated as true positive (75%) and 5 were false negative (25%). The total number of lesions in octreotide scintigraphy was 48 in 20 patients. Of 20 patients, 19 had FDG-PET study, 15 of them were evaluated as true positive (78.9%), and 4 them were evaluated as false negative (21.1%). Total number of lesions in FDG PET was 74. 99mTc-MIBI study was positive in 11 patients (55%) and negative in 9 patients (45%). Total number of lesions in 99mTc-MIBI was 25. Technetium-labeled somatostatin receptor scintigraphy analogues HYNIC-TOC and HYNIC-TATE are useful imaging alternatives in somatostatin receptor expressing thyroid cancer patients. Radiolabeling is easy and they are readily available for routine use.
28 CFR 32.28 - Reconsideration of negative disability finding.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Reconsideration of negative disability finding. 32.28 Section 32.28 Judicial Administration DEPARTMENT OF JUSTICE PUBLIC SAFETY OFFICERS' DEATH, DISABILITY, AND EDUCATIONAL ASSISTANCE BENEFIT CLAIMS Disability Benefit Claims § 32.28 Reconsideration of...
40 CFR 62.9515 - Identification of sources-Negative declaration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Identification of sources-Negative declaration. 62.9515 Section 62.9515 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Oregon Metals, Acid Gases, Organic Compounds, Particulates and Nitrogen Oxide Emissions from Existing...
28 CFR 32.28 - Reconsideration of negative disability finding.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 28 Judicial Administration 1 2011-07-01 2011-07-01 false Reconsideration of negative disability finding. 32.28 Section 32.28 Judicial Administration DEPARTMENT OF JUSTICE PUBLIC SAFETY OFFICERS' DEATH, DISABILITY, AND EDUCATIONAL ASSISTANCE BENEFIT CLAIMS Disability Benefit Claims § 32.28 Reconsideration of...
Is there a positive bias in false recognition? Evidence from confabulating amnesia patients.
Alkathiri, Nura H; Morris, Robin G; Kopelman, Michael D
2015-10-01
Although there is some evidence for a positive emotional bias in the content of confabulations in brain damaged patients, findings have been inconsistent. The present study used the semantic-associates procedure to induce false recall and false recognition in order to examine whether a positive bias would be found in confabulating amnesic patients, relative to non-confabulating amnesic patients and healthy controls. Lists of positive, negative and neutral words were presented in order to induce false recall or false recognition of non-presented (but semantically associated) words. The latter were termed 'critical intrusions'. Thirteen confabulating amnesic patients, 13 non-confabulating amnesic patients and 13 healthy controls were investigated. Confabulating patients falsely recognised a higher proportion of positive (but unrelated) words, compared with non-confabulating patients and healthy controls. No differences were found for recall memory. Signal detection analysis, however, indicated that the positive bias for false recognition memory might reflect weaker memory in the confabulating amnesic group. This suggested that amnesia patients with weaker memory are more likely to confabulate and the content of these confabulations are more likely to be positive. Copyright © 2015 Elsevier Ltd. All rights reserved.
Experimental investigation of observation error in anuran call surveys
McClintock, B.T.; Bailey, L.L.; Pollock, K.H.; Simons, T.R.
2010-01-01
Occupancy models that account for imperfect detection are often used to monitor anuran and songbird species occurrence. However, presenceabsence data arising from auditory detections may be more prone to observation error (e.g., false-positive detections) than are sampling approaches utilizing physical captures or sightings of individuals. We conducted realistic, replicated field experiments using a remote broadcasting system to simulate simple anuran call surveys and to investigate potential factors affecting observation error in these studies. Distance, time, ambient noise, and observer abilities were the most important factors explaining false-negative detections. Distance and observer ability were the best overall predictors of false-positive errors, but ambient noise and competing species also affected error rates for some species. False-positive errors made up 5 of all positive detections, with individual observers exhibiting false-positive rates between 0.5 and 14. Previous research suggests false-positive errors of these magnitudes would induce substantial positive biases in standard estimators of species occurrence, and we recommend practices to mitigate for false positives when developing occupancy monitoring protocols that rely on auditory detections. These recommendations include additional observer training, limiting the number of target species, and establishing distance and ambient noise thresholds during surveys. ?? 2010 The Wildlife Society.
Bandyopadhyay, Sanghamitra; Mitra, Ramkrishna
2009-10-15
Prediction of microRNA (miRNA) target mRNAs using machine learning approaches is an important area of research. However, most of the methods suffer from either high false positive or false negative rates. One reason for this is the marked deficiency of negative examples or miRNA non-target pairs. Systematic identification of non-target mRNAs is still not addressed properly, and therefore, current machine learning approaches are compelled to rely on artificially generated negative examples for training. In this article, we have identified approximately 300 tissue-specific negative examples using a novel approach that involves expression profiling of both miRNAs and mRNAs, miRNA-mRNA structural interactions and seed-site conservation. The newly generated negative examples are validated with pSILAC dataset, which elucidate the fact that the identified non-targets are indeed non-targets.These high-throughput tissue-specific negative examples and a set of experimentally verified positive examples are then used to build a system called TargetMiner, a support vector machine (SVM)-based classifier. In addition to assessing the prediction accuracy on cross-validation experiments, TargetMiner has been validated with a completely independent experimental test dataset. Our method outperforms 10 existing target prediction algorithms and provides a good balance between sensitivity and specificity that is not reflected in the existing methods. We achieve a significantly higher sensitivity and specificity of 69% and 67.8% based on a pool of 90 feature set and 76.5% and 66.1% using a set of 30 selected feature set on the completely independent test dataset. In order to establish the effectiveness of the systematically generated negative examples, the SVM is trained using a different set of negative data generated using the method in Yousef et al. A significantly higher false positive rate (70.6%) is observed when tested on the independent set, while all other factors are kept the same. Again, when an existing method (NBmiRTar) is executed with the our proposed negative data, we observe an improvement in its performance. These clearly establish the effectiveness of the proposed approach of selecting the negative examples systematically. TargetMiner is now available as an online tool at www.isical.ac.in/ approximately bioinfo_miu
Aly, Ibrahim; Taher, Eman E; El Nain, Gehan; El Sayed, Hoda; Mohammed, Faten A; Hamad, Rabab S; Bayoumy, Elsayed M
2018-01-01
Nanotechnology is a promising arena for generating new applications in Medicine. To successfully functionalised nanoparticles for a given biomedical application, a wide range of chemical, physical and biological factors have to be taken into account. Silica-coated nanoparticles, (SiO2NP) exhibit substantial diagnostic activity owing to their large surface to volume ratios and crystallographic surface structure. This work aimed to evaluate the advantage of bioconjugation of SiO2NP with PAb against Toxoplasma lyzate antigen (TLA) as an innovative diagnostic method for human toxoplasmosis. This cross-sectional study included 120 individuals, divided into Group I: 70 patients suspected for Toxoplasma gondii based on the presence of clinical manifestation. Group II: 30 patients harboring other parasites than T. gondii Group III: 20 apparently healthy individuals free from toxoplasmosis and other parasitic infections served as negative control. Detection of circulating Toxoplasma antigen was performed by Sandwich ELISA and Nano-sandwich ELISA on sera and pooled urine of human samples. Using Sandwich ELISA, 10 out of 70 suspected Toxoplasma-infected human serum samples showed false negative and 8 out of 30 of other parasites groups were false positive giving 85.7% sensitivity and 84.0% specificity, while the sensitivity and specificity were 78.6% and 70% respectively in urine samples. Using Nano-Sandwich ELISA, 7 out of 70 suspected Toxoplasma-infected human samples showed false negative results and the sensitivity of the assay was 90.0%, while 4 out of 30 of other parasites groups were false positive giving 92.0% specificity, while the sensitivity and specificity were 82.6% and 80% respectively in urine samples. In conclusion, our data demonstrated that loading SiO2 nanoparticles with pAb increased the sensitivity and specificity of Nano-sandwich ELISA for detection of T.gondii antigens in serum and urine samples, thus active (early) and light infections could be easily detected. Copyright © 2017 Elsevier B.V. All rights reserved.
van Brummelen, Sigrid E.; Bauwens, Anja M.; Schlösser, Noël J.; Arend, Sandra M.
2010-01-01
Treatment of latent Mycobacterium tuberculosis infection on the basis of the tuberculin skin test (TST) result is inaccurate due to the false-positive TST results that occur after Mycobacterium bovis BCG vaccination or exposure to nontuberculous mycobacteria (NTM). Gamma interferon release assays (IGRAs) are based on M. tuberculosis-specific antigens. In a previous study among BCG-naïve military employees, a positive TST result after deployment was mostly associated with a negative IGRA result, suggesting exposure to NTM. Data regarding the kinetics of IGRAs are limited and controversial. The present study aimed to reassess the rate of false-positive TST results and to evaluate the kinetics of the Quantiferon TB Gold In-Tube assay (QFT-Git) in military personnel with a positive TST result. QFT-Git was performed at the time of inclusion in the study and was repeated after 2, 6, 12, and 18 or 24 months. Of 192 participants, 17 were recruits and 175 were screened after deployment (n = 169) or because of travel or health care work. Baseline positive QFT-Git results were observed in 7/17 (41.2%) and 12/174 (6.9%) participants, respectively. During follow-up, a negative QFT-Git result remained negative in 163/165 (98.8%) participants. Of 18 subjects with an initial positive QFT-Git result, reversion to a negative result occurred in 1/6 (16%) recruits, whereas it occurred in 8/12 (66%) subjects after deployment or with other risk factors (P = 0.046). The quantitative result was significantly lower in subjects with reversion than in those with consistent positive results (P = 0.017). This study confirmed a low rate of positive QFT-Git results among military personnel with a positive TST result after deployment, supporting the hypothesis of exposure to NTM. Reversion of the majority of initially low-positive QFT-Git results indicates that QFT-Git may be useful for the diagnosis of later reinfections. PMID:20375241
99mTc-EDDA/HYNIC-TOC and (18)F-FDG in thyroid cancer patients with negative (131)I whole-body scans.
Gabriel, Michael; Froehlich, Franz; Decristoforo, Clemens; Ensinger, Christian; Donnemiller, Eveline; von Guggenberg, Elisabeth; Heute, Dirk; Moncayo, Roy
2004-03-01
Several studies have reported on the expression of somatostatin receptors in patients with differentiated thyroid cancer (DTC). The aim of this study was to evaluate the imaging abilities of a recently developed technetium-99m labelled somatostatin analogue, (99m)Tc-EDDA/HYNIC-TOC ((99m)Tc-TOC), in terms of precise localisation of disease. The study population comprised 54 patients (24 men, 30 women; age range 22-90 years) with histologically confirmed DTC who presented with recurrent or persistent disease as indicated by elevated Tg levels after initial treatment. All patients were negative on the iodine-131 post-therapy whole-body scans. Fluorine-18 fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) was performed in a subgroup of 36 patients. The study population consisted of two groups: Group A ( n=22) comprised patients with disease recurrence as shown by elevated Tg levels but without detectable pathology. In group B ( n=32), pre-existing lesions were known. Among the 54 cases, SSTR scintigraphy was true positive in 33 (61.1%), true negative in 4 (7.4%) and false negative in 17 (31.5%) cases, which resulted in a sensitivity of 66%. A total of 138 tumour foci were localised in 33 patients. The fraction of true positive (99m)Tc-TOC findings was positively correlated ( P<0.01) with elevated Tg levels (higher than 30 ng/ml). Despite two false positive findings, analysis on a lesion basis demonstrated better diagnostic efficacy with (18)F-FDG PET ( P<0.001); however, it also revealed substantial agreement between the imaging techniques [Cohen's kappa of 0.62 (0.47-0.78)]. In conclusion, scintigraphy with (99m)Tc-TOC might be a promising tool for treatment planning; it is easy to perform and showed sufficient accuracy for localisation diagnostics in thyroid cancer patients with recurrent or metastatic disease.
Perandini, Simone; Soardi, Gian Alberto; Motton, Massimiliano; Rossi, Arianna; Signorini, Manuel; Montemezzi, Stefania
2016-09-01
The aim of this study was to compare classification results from four major risk prediction models in a wide population of incidentally detected solitary pulmonary nodules (SPNs) which were selected to crossmatch inclusion criteria for the selected models. A total of 285 solitary pulmonary nodules with a definitive diagnosis were evaluated by means of four major risk assessment models developed from non-screening populations, namely the Mayo, Gurney, PKUPH and BIMC models. Accuracy was evaluated by receiver operating characteristic (ROC) area under the curve (AUC) analysis. Each model's fitness to provide reliable help in decision analysis was primarily assessed by adopting a surgical threshold of 65 % and an observation threshold of 5 % as suggested by ACCP guidelines. ROC AUC values, false positives, false negatives and indeterminate nodules were respectively 0.775, 3, 8, 227 (Mayo); 0.794, 41, 6, 125 (Gurney); 0.889, 42, 0, 144 (PKUPH); 0.898, 16, 0, 118 (BIMC). Resultant data suggests that the BIMC model may be of greater help than Mayo, Gurney and PKUPH models in preoperative SPN characterization when using ACCP risk thresholds because of overall better accuracy and smaller numbers of indeterminate nodules and false positive results. • The BIMC and PKUPH models offer better characterization than older prediction models • Both the PKUPH and BIMC models completely avoided false negative results • The Mayo model suffers from a large number of indeterminate results.
First-trimester visualization of the fourth ventricle in fetuses with and without spina bifida.
Solt, Ido; Acuna, Joann G; Adeniji, Beni A; Mirocha, James; Kim, Matthew J; Rotmensch, Siegfried
2011-12-01
The purpose of this study was to examine the efficacy of nonvisualization of the fourth ventricle for first-trimester detection of spina bifida. A total of 250 digitally stored sonographic examinations at gestational ages of 11 weeks to 13 weeks 6 days (245 normal and 5 randomly interspersed spina bifida cases) were retrospectively analyzed by 4 blinded reviewers for the presence or absence of the fourth ventricle followed by an anteroposterior ventricular dimension measurement. The ventricle size was related to the crown-rump length and gestational age by linear regression analysis and Pearson correlation. The fourth ventricle was identified in 971 of 1000 image readings (97.1%). False-negative and false-positive readings occurred in 11 of 20 (55.0%) and 20 of 980 (2.0%) cases, respectively (sensitivity, 0.45; specificity, 0.98.). False-negative and false-positive readings were evenly distributed throughout the gestational age range. When the ventricular size was measurable, its mean dimensions increased linearly with gestational age and were below the fifth percentile in 10 of 245 (4.0%) normal and 0 of 4 spina bifida cases, respectively. Intraclass correlation coefficient estimates were calculated based on the 2-way analysis of variance model and found to be 0.30 for a single rater and 0.64 for the mean of 4 raters. Nonvisualization of the first-trimester fourth ventricle is a less robust screening parameter for spina bifida than previously published.
Langeslag-Smith, Miriam A; Vandal, Alain C; Briane, Vincent; Thompson, Benjamin; Anstice, Nicola S
2015-11-27
To assess the accuracy of preschool vision screening in a large, ethnically diverse, urban population in South Auckland, New Zealand. Retrospective longitudinal study. B4 School Check vision screening records (n=5572) were compared with hospital eye department data for children referred from screening due to impaired acuity in one or both eyes who attended a referral appointment (n=556). False positive screens were identified by comparing screening data from the eyes that failed screening with hospital data. Estimation of false negative screening rates relied on data from eyes that passed screening. Data were analysed using logistic regression modelling accounting for the high correlation between results for the two eyes of each child. Positive predictive value of the preschool vision screening programme. Screening produced high numbers of false positive referrals, resulting in poor positive predictive value (PPV=31%, 95% CI 26% to 38%). High estimated negative predictive value (NPV=92%, 95% CI 88% to 95%) suggested most children with a vision disorder were identified at screening. Relaxing the referral criteria for acuity from worse than 6/9 to worse than 6/12 improved PPV without adversely affecting NPV. The B4 School Check generated numerous false positive referrals and consequently had a low PPV. There is scope for reducing costs by altering the visual acuity criterion for referral. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Cistaro, Angelina; Cassalia, Laura; Ferrara, Cinzia; Quartuccio, Natale; Evangelista, Laura; Bianchi, Maurizio; Fagioli, Franca; Bisi, Gianni; Baldari, Sergio; Zanella, Alessandro; Pillon, Marta; Zucchetta, Pietro; Burei, Marta; Sala, Alessandra; Guerra, Luca; Guglielmo, Priscilla; Burnelli, Roberta; Panareo, Stefano; Scalorbi, Federica; Rambaldi, Ilaria; Piccardo, Arnoldo; Garaventa, Alberto; Familiari, Demetrio; Fornito, Maria Concetta; Lopci, Egesta; Mascarin, Maurizio; Altini, Corinna; Ferrari, Cristina; Perillo, Teresa; Santoro, Nicola; Borsatti, Eugenio; Rubini, Giuseppe
2018-06-01
The present study investigated the utility of fluorine-18 ( 18 F) fluoro-2-deoxy-d-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) in assessing bone marrow involvement (BMI) compared with bone marrow biopsy (BMB) in newly diagnosed pediatric Hodgkin lymphoma (HL). A total of 224 pediatric patients with HL underwent 18 F-FDG PET/CT at staging. BMB or follow-up imaging was used as the standard of reference for the evaluation of BMI. 18 F-FDG PET/CT was negative for BMI in 193 cases. Of the 193 patients, the findings for 16 were originally reported as doubtful and later interpreted as negative for BMI, with negative findings on follow-up imaging and BMB. At BMB, 1 of the 16 patients (6.25%) had BMI. Of the 193 patients, 192 (99.48%) had negative BMB findings. Thus, the 18 F-FDG PET/CT findings were truly negative for 192 patients and falsely negative for 1 patient for BMI. 18 F-FDG PET/CT showed high diagnostic performance in the evaluation of BMI in pediatric HL. Thus, BMB should be ideally reserved for patients presenting with doubtful 18 F-FDG PET/CT findings for BMI. Copyright © 2018 Elsevier Inc. All rights reserved.
Serologic screening for Trypanosoma cruzi among blood donors in central Brazil.
de Andrade, A L; Martelli, C M; Luquetti, A O; de Oliveira, O S; Almeida e Silva, S; Zicker, F
1992-01-01
The study reported here compares results obtained by blood banks screening sera for chagasic (Trypanosoma cruzi) infection with results obtained by the Chagas' Disease Reference Laboratory of the Federal University of Goiás in Goiânia, Brazil. It also evaluates results obtained using the ELISA technique to screen the study sera. The survey used data from six of eight blood banks serving the city of Goiânia, an urban region of Central Brazil where Chagas' disease is highly endemic. The survey population consisted of 1,513 voluntary first-time blood donors whose donations occurred between October 1988 and April 1989. This group included 50% of all the first-time blood donors in that period. The six participating blood banks, which accounted for about 90% of all blood donations in Goiânia during the study period, routinely used indirect hemagglutination (IHA) and complement fixation (CF) tests to screen sera for antibodies to T. cruzi. Comparison of the results provided by the blood banks with the reference laboratory's results indicated a relative sensitivity of 77%, which ranged from 50% to 100% depending on the blood bank studied. The comparison, which found 12 false negative results, indicated that transfusions of infected blood might have occurred despite the serologic screening performed by the blood banks. Relative to the standard of positivity established for the study, the enzyme-linked immunosorbent assay (ELISA) technique was found to have a sensitivity of 96.3%. Considering as positive only those sera yielding positive IHA and indirect immunofluorescence (IIF) test results, the ELISA technique yielded 2 false negative and 41 false positive responses.(ABSTRACT TRUNCATED AT 250 WORDS)
Piwowar-Manning, Estelle; Fogel, Jessica M.; Richardson, Paul; Wolf, Shauna; Clarke, William; Marzinke, Mark A.; Fiamma, Agnès; Donnell, Deborah; Kulich, Michal; Mbwambo, Jessie K.K.; Richter, Linda; Gray, Glenda; Sweat, Michael; Coates, Thomas J.; Eshleman, Susan H.
2015-01-01
Background Fourth-generation HIV assays detect both antigen and antibody, facilitating detection of acute/early HIV infection. The Bio-Rad GS HIV Combo Ag/Ab assay (Bio-Rad Combo) is an enzyme immunoassay that simultaneously detects HIV p24 antigen and antibodies to HIV-1 and HIV-2 in serum or plasma. Objective To evaluate the performance of the Bio-Rad Combo assay for detection of HIV infection in adults from Southern Africa. Study design Samples were obtained from adults in Soweto and Vulindlela, South Africa and Dar es Salaam, Tanzania (300 HIV-positive samples; 300 HIV-negative samples; 12 samples from individuals previously classified as having acute/early HIV infection). The samples were tested with the Bio-Rad Combo assay. Additional testing was performed to characterize the 12 acute/early samples. Results All 300 HIV-positive samples were reactive using the Bio-Rad Combo assay; false positive test results were obtained for 10 (3.3%) of the HIV-negative samples (sensitivity: 100%, 95% confidence interval [CI]: 98.8–100%); specificity: 96.7%, 95% CI: 94.0–98.4%). The assay detected 10 of the 12 infections classified as acute/early. The two infections that were not detected had viral loads < 400 copies/mL; one of those samples contained antiretroviral drugs consistent with antiretroviral therapy. Conclusions The Bio-Rad Combo assay correctly classified the majority of study specimens. The specificity reported here may be higher than that seen in other settings, since HIV-negative samples were pre-screened using a different fourth-generation test. The assay also had high sensitivity for detection of acute/early infection. False-negative test results may be obtained in individuals who are virally suppressed. PMID:25542477
Intraoperative ultrasound control of surgical margins during partial nephrectomy.
Alharbi, Feras M; Chahwan, Charles K; Le Gal, Sophie G; Guleryuz, Kerem M; Tillou, Xavier P; Doerfler, Arnaud P
2016-01-01
To evaluate a simple and fast technique to ensure negative surgical margins on partial nephrectomies, while correlating margin statuses with the final pathology report. This study was conducted for patients undergoing partial nephrectomy (PN) with T1-T2 renal tumors from January 2010 to the end of December 2015. Before tumor removal, intraoperative ultrasound (US) localization was performed. After tumor removal and before performing hemostasis of the kidney, the specimens were placed in a saline solution and a US was performed to evaluate if the tumor's capsule were intact, and then compared to the final pathology results. In 177 PN(s) (147 open procedures and 30 laparoscopic procedures) were performed on 147 patients. Arterial clamping was done for 32 patients and the mean warm ischemia time was 19 ± 6 min. The mean US examination time was 41 ± 7 s. The US analysis of surgical margins was negative in 172 cases, positive in four, and in only one case it was not possible to conclude. The final pathology results revealed one false positive surgical margin and one false negative surgical margin, while all other margins were in concert with US results. The mean tumor size was 3.53 ± 1.43 cm, and the mean surgical margin was 2.8 ± 1.5 mm. The intraoperative US control of resection margins in PN is a simple, efficient, and effective method for ensuring negative surgical margins with a small increase in warm ischemia time and can be conducted by the operating urologist.
False Belief vs. False Photographs: A Test of Theory of Mind or Working Memory?
Callejas, Alicia; Shulman, Gordon L; Corbetta, Maurizio
2011-01-01
Theory of mind (ToM), the ability to reason about other people's thoughts and beliefs, has been traditionally studied in behavioral and neuroimaging experiments by comparing performance in "false belief" and "false photograph" (control) stories. However, some evidence suggests that these stories are not matched in difficulty, complicating the interpretation of results. Here, we more fully evaluated the relative difficulty of comprehending these stories and drawing inferences from them. Subjects read false belief and false photograph stories followed by comprehension questions that probed true ("reality" questions) or false beliefs ("representation" questions) appropriate to the stories. Stories and comprehension questions were read and answered, respectively, more slowly in the false photograph than false belief conditions, indicating their greater difficulty. Interestingly, accuracy on representation questions for false photograph stories was significantly lower than for all other conditions and correlated positively with participants' working memory span scores. These results suggest that drawing representational inferences from false photo stories is particularly difficult and places heavy demands on working memory. Extensive naturalistic practice with ToM reasoning may enable a more flexible and efficient mental representation of false belief stories, resulting in lower memory load requirements. An important implication of these results is that the differential modulation of right temporal-parietal junction (RTPJ) during ToM and "false photo" control conditions may reflect the documented negative correlation of RTPJ activity with working memory load rather than a specialized involvement in ToM processes.
Controlling false-negative errors in microarray differential expression analysis: a PRIM approach.
Cole, Steve W; Galic, Zoran; Zack, Jerome A
2003-09-22
Theoretical considerations suggest that current microarray screening algorithms may fail to detect many true differences in gene expression (Type II analytic errors). We assessed 'false negative' error rates in differential expression analyses by conventional linear statistical models (e.g. t-test), microarray-adapted variants (e.g. SAM, Cyber-T), and a novel strategy based on hold-out cross-validation. The latter approach employs the machine-learning algorithm Patient Rule Induction Method (PRIM) to infer minimum thresholds for reliable change in gene expression from Boolean conjunctions of fold-induction and raw fluorescence measurements. Monte Carlo analyses based on four empirical data sets show that conventional statistical models and their microarray-adapted variants overlook more than 50% of genes showing significant up-regulation. Conjoint PRIM prediction rules recover approximately twice as many differentially expressed transcripts while maintaining strong control over false-positive (Type I) errors. As a result, experimental replication rates increase and total analytic error rates decline. RT-PCR studies confirm that gene inductions detected by PRIM but overlooked by other methods represent true changes in mRNA levels. PRIM-based conjoint inference rules thus represent an improved strategy for high-sensitivity screening of DNA microarrays. Freestanding JAVA application at http://microarray.crump.ucla.edu/focus