Taylor, Darlene; Durigon, Monica; Davis, Heather; Archibald, Chris; Konrad, Bernhard; Coombs, Daniel; Gilbert, Mark; Cook, Darrel; Krajden, Mel; Wong, Tom; Ogilvie, Gina
2015-03-01
Failure to understand the risk of false-negative HIV test results during the window period results in anxiety. Patients typically want accurate test results as soon as possible while clinicians prefer to wait until the probability of a false-negative is virtually nil. This review summarizes the median window periods for third-generation antibody and fourth-generation HIV tests and provides the probability of a false-negative result for various days post-exposure. Data were extracted from published seroconversion panels. A 10-day eclipse period was used to estimate days from infection to first detection of HIV RNA. Median (interquartile range) days to seroconversion were calculated and probabilities of a false-negative result at various time periods post-exposure are reported. The median (interquartile range) window period for third-generation tests was 22 days (19-25) and 18 days (16-24) for fourth-generation tests. The probability of a false-negative result is 0.01 at 80 days' post-exposure for third-generation tests and at 42 days for fourth-generation tests. The table of probabilities of falsely-negative HIV test results may be useful during pre- and post-test HIV counselling to inform co-decision making regarding the ideal time to test for HIV. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
[Roaming through methodology. XXXII. False test results].
van der Weijden, T; van den Akker, M
2001-05-12
The number of requests for diagnostic tests is rising. This leads to a higher chance of false test results. The false-negative proportion of a test is the proportion of negative test results among the diseased subjects. The false-positive proportion is the proportion of positive test results among the healthy subjects. The calculation of the false-positive proportion is often incorrect. For example, instead of 1 minus the specificity it is calculated as 1 minus the positive predictive value. This can lead to incorrect decision-making with respect to the application of the test. Physicians must apply diagnostic tests in such a way that the risk of false test results is minimal. The patient should be aware that a perfectly conclusive diagnostic test is rare in medical practice, and should more often be informed of the implications of false-positive and false-negative test results.
Koita, Ousmane A; Doumbo, Ogobara K; Ouattara, Amed; Tall, Lalla K; Konaré, Aoua; Diakité, Mahamadou; Diallo, Mouctar; Sagara, Issaka; Masinde, Godfred L; Doumbo, Safiatou N; Dolo, Amagana; Tounkara, Anatole; Traoré, Issa; Krogstad, Donald J
2012-02-01
We identified 480 persons with positive thick smears for asexual Plasmodium falciparum parasites, of whom 454 had positive rapid diagnostic tests (RDTs) for the histidine-rich protein 2 (HRP2) product of the hrp2 gene and 26 had negative tests. Polymerase chain reaction (PCR) amplification for the histidine-rich repeat region of that gene was negative in one-half (10/22) of false-negative specimens available, consistent with spontaneous deletion. False-negative RDTs were found only in persons with asymptomatic infections, and multiplicities of infection (MOIs) were lower in persons with false-negative RDTs (both P < 0.001). These results show that parasites that fail to produce HRP2 can cause patent bloodstream infections and false-negative RDT results. The importance of these observations is likely to increase as malaria control improves, because lower MOIs are associated with false-negative RDTs and false-negative RDTs are more frequent in persons with asymptomatic infections. These findings suggest that the use of HRP2-based RDTs should be reconsidered.
Muthukumar, Alagarraju; Alatoom, Adnan; Burns, Susan; Ashmore, Jerry; Kim, Anne; Emerson, Brian; Bannister, Edward; Ansari, M Qasim
2015-01-01
To assess the false-positive and false-negative rates of a 4th-generation human immunodeficiency virus (HIV) assay, the Abbott ARCHITECT, vs 2 HIV 3rd-generation assays, the Siemens Centaur and the Ortho-Clinical Diagnostics Vitros. We examined 123 patient specimens. In the first phase of the study, we compared 99 specimens that had a positive screening result via the 3rd-generation Vitros assay (10 positive, 82 negative, and 7 indeterminate via confirmatory immunofluorescent assay [IFA]/Western blot [WB] testing). In the second phase, we assessed 24 HIV-1 RNA-positive (positive result via the nuclear acid amplification test [NAAT] and negative/indeterminate results via the WB test) specimens harboring acute HIV infection. The 4th-generation ARCHITECT assay yielded fewer false-positive results (n = 2) than the 3rd-generation Centaur (n = 9; P = .02) and Vitros (n = 82; P <.001) assays. One confirmed positive case had a false-negative result via the Centaur assay. When specimens from the 24 patients with acute HIV-1 infection were tested, the ARCHITECT assay yielded fewer false-negative results (n = 5) than the Centaur (n = 10) (P = .13) and the other 3rd-generation tests (n = 16) (P = .002). This study indicates that the 4th-generation ARCHITECT HIV assay yields fewer false-positive and false-negative results than the 3rd-generation HIV assays we tested. Copyright© by the American Society for Clinical Pathology (ASCP).
High false-negative rate of anti-HCV among Egyptian patients on regular hemodialysis.
El-Sherif, Assem; Elbahrawy, Ashraf; Aboelfotoh, Atef; Abdelkarim, Magdy; Saied Mohammad, Abdel-Gawad; Abdallah, Abdallah Mahmoud; Mostafa, Sadek; Elmestikawy, Amr; Elwassief, Ahmed; Salah, Mohamed; Abdelbaseer, Mohamed Ali; Abdelwahab, Kouka Saadeldin
2012-07-01
Routine serological testing for hepatitis C virus (HCV) infection among hemodialysis (HD) patients is currently recommended. A dilemma existed on the value of serology because some investigators reported a high rate of false-negative serologic testing. In this study, we aimed to detect the false-negative rate of anti-HCV among Egyptian HD patients. Seventy-eight HD patients, negative for anti-HCV, anti-HIV, and hepatitis B surface antigen, were tested for HCV RNA by reverse transcriptase polymerase chain reaction (RT-PCR). In the next step, the viral load was quantified by real-time PCR in RT-PCR-positive patients. Risk factors for HCV infection, as well as clinical and biochemical indicators of liver disease, were compared between false-negative and true-negative anti-HCV HD patients. The frequency of false-negative anti-HCV was 17.9%. Frequency of blood transfusion, duration of HD, dialysis at multiple centers, and diabetes mellitus were not identified as risk factors for HCV infection. The frequency of false-negative results had a linear relation to the prevalence of HCV infection in the HD units. Timely identification of HCV within dialysis units is needed in order to lower the risk of HCV spread within the HD units. The high false-negative rate of anti-HCV among HD patients in our study justifies testing of a large scale of patients for precious assessment of effectiveness of nucleic acid amplification technology testing in screening HD patient. © 2012 The Authors. Hemodialysis International © 2012 International Society for Hemodialysis.
Griffey, Richard T; Trent, Caleb J; Bavolek, Rebecca A; Keeperman, Jacob B; Sampson, Christopher; Poirier, Robert F
2013-01-01
Failure to detect pregnancy in the emergency department (ED) can have important consequences. Urine human chorionic gonadotropin (uhCG) point-of-care (POC) assays are valued for rapidly detecting early pregnancy with high sensitivity. However, under certain conditions, POC uhCG tests can fail to detect pregnancy. In investigating a series of late first-trimester false-negative pregnancy tests in our ED, a novel and distinct causative phenomenon was recently elucidated in our institution. We discuss uhCG POC tests, review our false-negative rate, and describe mechanisms for false negatives and potential remedies. The false-negative POC uhCG rate is very low, but in the setting of a large volume of tests, the numbers are worth consideration. In positive uhCG POC tests, free and fixed antibodies bind hCG to form a "sandwich"; hCG is present in several variant forms that change in their concentrations at different stages of pregnancy. When in excess, intact hCG can saturate the antibodies, preventing sandwich formation (hook effect phenomenon). Some assays may include an antibody that does not recognize certain variants present in later stages of pregnancy. When this variant is in excess, it can bind one antibody avidly and the other not at all, resulting in a false-negative test (hook-like phenomenon). In both situations, dilution is key to an accurate test. Manufacturers should consider that uhCG tests are routinely used at many stages of pregnancy. Characterizing uhCG variants recognized by their tests and eliminating lot-to-lot variability may help improve uhCG test performance. Clinicians need to be aware of and familiarize themselves with the limitations of the specific type of uhCG POC tests used in their practice, recognizing that under certain circumstances, false-negative tests can occur. Copyright © 2013 Elsevier Inc. All rights reserved.
Narita, Kazuto; Ishii, Yuuki; Vo, Phuc Thi Hong; Nakagawa, Fumiko; Ogata, Shinichi; Yamashita, Kunihiko; Kojima, Hajime; Itagaki, Hiroshi
2018-01-01
Recently, animal testing has been affected by increasing ethical, social, and political concerns regarding animal welfare. Several in vitro safety tests for evaluating skin sensitization, such as the human cell line activation test (h-CLAT), have been proposed. However, similar to other tests, the h-CLAT has produced false-negative results, including in tests for acid anhydride and water-insoluble chemicals. In a previous study, we demonstrated that the cause of false-negative results from phthalic anhydride was hydrolysis by an aqueous vehicle, with IL-8 release from THP-1 cells, and that short-time exposure to liquid paraffin (LP) dispersion medium could reduce false-negative results from acid anhydrides. In the present study, we modified the h-CLAT by applying this exposure method. We found that the modified h-CLAT is a promising method for reducing false-negative results obtained from acid anhydrides and chemicals with octanol-water partition coefficients (LogK ow ) greater than 3.5. Based on the outcomes from the present study, a combination of the original and the modified h-CLAT is suggested for reducing false-negative results. Notably, the combination method provided a sensitivity of 95% (overall chemicals) or 93% (chemicals with LogK ow > 2.0), and an accuracy of 88% (overall chemicals) or 81% (chemicals with LogK ow > 2.0). We found that the combined method is a promising evaluation scheme for reducing false-negative results seen in existing in vitro skin-sensitization tests. In the future, we expect a combination of original and modified h-CLAT to be applied in a newly developed in vitro test for evaluating skin sensitization.
Kufa, Tendesayi; Lane, Tim; Manyuchi, Albert; Singh, Beverley; Isdahl, Zachary; Osmand, Thomas; Grasso, Mike; Struthers, Helen; McIntyre, James; Chipeta, Zawadi; Puren, Adrian
2017-01-01
Abstract We describe the accuracy of serial rapid HIV testing among men who have sex with men (MSM) in South Africa and discuss the implications for HIV testing and prevention. This was a cross-sectional survey conducted at five stand-alone facilities from five provinces. Demographic, behavioral, and clinical data were collected. Dried blood spots were obtained for HIV-related testing. Participants were offered rapid HIV testing using 2 rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using a third-generation enzyme immunoassay (EIA) and a fourth-generation EIA as confirmatory. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive, and false-negative rates were determined. Between August 2015 and July 2016, 2503 participants were enrolled. Of these, 2343 were tested by RDT on site with a further 2137 (91.2%) having definitive results on both RDT and EIA. Sensitivity, specificity, positive predictive value, negative predictive value, false-positive rates, and false-negative rates were 92.6% [95% confidence interval (95% CI) 89.6–94.8], 99.4% (95% CI 98.9–99.7), 97.4% (95% CI 95.2–98.6), 98.3% (95% CI 97.6–98.8), 0.6% (95% CI 0.3–1.1), and 7.4% (95% CI 5.2–10.4), respectively. False negatives were similar to true positives with respect to virological profiles. Overall accuracy of the RDT algorithm was high, but sensitivity was lower than expected. Post-HIV test counseling should include discussions of possible false-negative results and the need for retesting among HIV negatives. PMID:28700474
Linguistic Determinants of the Difficulty of True-False Test Items
ERIC Educational Resources Information Center
Peterson, Candida C.; Peterson, James L.
1976-01-01
Adults read a prose passage and responded to passages based on it which were either true or false and were phrased either affirmatively or negatively. True negatives yielded most errors, followed in order by false negatives, true affirmatives, and false affirmatives. (Author/RC)
Bruijn, Merel M C; Hermans, Frederik J R; Vis, Jolande Y; Wilms, Femke F; Oudijk, Martijn A; Kwee, Anneke; Porath, Martina M; Oei, Guid; Scheepers, Hubertina C J; Spaanderman, Marc E A; Bloemenkamp, Kitty W M; Haak, Monique C; Bolte, Antoinette C; Vandenbussche, Frank P H A; Woiski, Mallory D; Bax, Caroline J; Cornette, Jérôme M J; Duvekot, Johannes J; Bijvank, Bas W A N I J; van Eyck, Jim; Franssen, Maureen T M; Sollie, Krystyna M; van der Post, Joris A M; Bossuyt, Patrick M M; Kok, Marjolein; Mol, Ben W J; van Baaren, Gert-Jan
2017-02-01
Objective We assessed the influence of external factors on false-positive, false-negative, and invalid fibronectin results in the prediction of spontaneous delivery within 7 days. Methods We studied symptomatic women between 24 and 34 weeks' gestational age. We performed uni- and multivariable logistic regression to estimate the effect of external factors (vaginal soap, digital examination, transvaginal sonography, sexual intercourse, vaginal bleeding) on the risk of false-positive, false-negative, and invalid results, using spontaneous delivery within 7 days as the outcome. Results Out of 708 women, 237 (33%) had a false-positive result; none of the factors showed a significant association. Vaginal bleeding increased the proportion of positive fetal fibronectin (fFN) results, but was significantly associated with a lower risk of false-positive test results (odds ratio [OR], 0.22; 95% confidence intervals [CI], 0.12-0.39). Ten women (1%) had a false-negative result. None of the investigated factors was significantly associated with a significantly higher risk of false-negative results. Twenty-one tests (3%) were invalid; only vaginal bleeding showed a significant association (OR, 4.5; 95% CI, 1.7-12). Conclusion The effect of external factors on the performance of qualitative fFN testing is limited, with vaginal bleeding as the only factor that reduces its validity. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Kufa, Tendesayi; Kharsany, Ayesha BM; Cawood, Cherie; Khanyile, David; Lewis, Lara; Grobler, Anneke; Chipeta, Zawadi; Bere, Alfred; Glenshaw, Mary; Puren, Adrian
2017-01-01
Abstract Introduction: We describe the overall accuracy and performance of a serial rapid HIV testing algorithm used in community-based HIV testing in the context of a population-based household survey conducted in two sub-districts of uMgungundlovu district, KwaZulu-Natal, South Africa, against reference fourth-generation HIV-1/2 antibody and p24 antigen combination immunoassays. We discuss implications of the findings on rapid HIV testing programmes. Methods: Cross-sectional design: Following enrolment into the survey, questionnaires were administered to eligible and consenting participants in order to obtain demographic and HIV-related data. Peripheral blood samples were collected for HIV-related testing. Participants were offered community-based HIV testing in the home by trained field workers using a serial algorithm with two rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using two fourth-generation immunoassays with all positives in the confirmatory test considered true positives. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value and false-positive and false-negative rates were determined. Results: Of 10,236 individuals enrolled in the survey, 3740 were tested in the home (median age 24 years (interquartile range 19–31 years), 42.1% males and HIV positivity on RDT algorithm 8.0%). From those tested, 3729 (99.7%) had a definitive RDT result as well as a laboratory immunoassay result. The overall accuracy of the RDT when compared to the fourth-generation immunoassays was 98.8% (95% confidence interval (CI) 98.5–99.2). The sensitivity, specificity, positive predictive value and negative predictive value were 91.1% (95% CI 87.5–93.7), 99.9% (95% CI 99.8–100), 99.3% (95% CI 97.4–99.8) and 99.1% (95% CI 98.8–99.4) respectively. The false-positive and false-negative rates were 0.06% (95% CI 0.01–0.24) and 8.9% (95% CI 6.3–12.53). Compared to true positives, false negatives were more likely to be recently infected on limited antigen avidity assay and to report antiretroviral therapy (ART) use. Conclusions: The overall accuracy of the RDT algorithm was high. However, there were few false positives, and the sensitivity was lower than expected with high false negatives, despite implementation of quality assurance measures. False negatives were associated with recent (early) infection and ART exposure. The RDT algorithm was able to correctly identify the majority of HIV infections in community-based HIV testing. Messaging on the potential for false positives and false negatives should be included in these programmes. PMID:28872274
Johnson, Cheryl C; Fonner, Virginia; Sands, Anita; Ford, Nathan; Obermeyer, Carla Mahklouf; Tsui, Sharon; Wong, Vincent; Baggaley, Rachel
2017-08-29
In accordance with global testing and treatment targets, many countries are seeking ways to reach the "90-90-90" goals, starting with diagnosing 90% of all people with HIV. Quality HIV testing services are needed to enable people with HIV to be diagnosed and linked to treatment as early as possible. It is essential that opportunities to reach people with undiagnosed HIV are not missed, diagnoses are correct and HIV-negative individuals are not inadvertently initiated on life-long treatment. We conducted this systematic review to assess the magnitude of misdiagnosis and to describe poor HIV testing practices using rapid diagnostic tests. We systematically searched peer-reviewed articles, abstracts and grey literature published from 1 January 1990 to 19 April 2017. Studies were included if they used at least two rapid diagnostic tests and reported on HIV misdiagnosis, factors related to potential misdiagnosis or described quality issues and errors related to HIV testing. Sixty-four studies were included in this review. A small proportion of false positive (median 3.1%, interquartile range (IQR): 0.4-5.2%) and false negative (median: 0.4%, IQR: 0-3.9%) diagnoses were identified. Suboptimal testing strategies were the most common factor in studies reporting misdiagnoses, particularly false positive diagnoses due to using a "tiebreaker" test to resolve discrepant test results. A substantial proportion of false negative diagnoses were related to retesting among people on antiretroviral therapy. Conclusions HIV testing errors and poor practices, particularly those resulting in false positive or false negative diagnoses, do occur but are preventable. Efforts to accelerate HIV diagnosis and linkage to treatment should be complemented by efforts to improve the quality of HIV testing services and strengthen the quality management systems, particularly the use of validated testing algorithms and strategies, retesting people diagnosed with HIV before initiating treatment and providing clear messages to people with HIV on treatment on the risk of a "false negative" test result.
Misinformation, partial knowledge and guessing in true/false tests.
Burton, Richard F
2002-09-01
Examiners disagree on whether or not multiple choice and true/false tests should be negatively marked. Much of the debate has been clouded by neglect of the role of misinformation and by vagueness regarding both the specification of test types and "partial knowledge" in relation to guessing. Moreover, variations in risk-taking in the face of negative marking have too often been treated in absolute terms rather than in relation to the effect of guessing on test unreliability. This paper aims to clarify these points and to compare the ill-effects on test reliability of guessing and of variable risk-taking. Three published studies on medical students are examined. These compare responses in true/false tests obtained with both negative marking and number-right scoring. The studies yield data on misinformation and on the extent to which students may fail to benefit from distrusted partial knowledge when there is negative marking. A simple statistical model is used to compare variations in risk-taking with test unreliability due to blind guessing under number-right scoring conditions. Partial knowledge should be least problematic with independent true/false items. The effect on test reliability of blind guessing under number-right conditions is generally greater than that due to the over-cautiousness of some students when there is negative marking.
Comparing diagnostic tests on benefit-risk.
Pennello, Gene; Pantoja-Galicia, Norberto; Evans, Scott
2016-01-01
Comparing diagnostic tests on accuracy alone can be inconclusive. For example, a test may have better sensitivity than another test yet worse specificity. Comparing tests on benefit risk may be more conclusive because clinical consequences of diagnostic error are considered. For benefit-risk evaluation, we propose diagnostic yield, the expected distribution of subjects with true positive, false positive, true negative, and false negative test results in a hypothetical population. We construct a table of diagnostic yield that includes the number of false positive subjects experiencing adverse consequences from unnecessary work-up. We then develop a decision theory for evaluating tests. The theory provides additional interpretation to quantities in the diagnostic yield table. It also indicates that the expected utility of a test relative to a perfect test is a weighted accuracy measure, the average of sensitivity and specificity weighted for prevalence and relative importance of false positive and false negative testing errors, also interpretable as the cost-benefit ratio of treating non-diseased and diseased subjects. We propose plots of diagnostic yield, weighted accuracy, and relative net benefit of tests as functions of prevalence or cost-benefit ratio. Concepts are illustrated with hypothetical screening tests for colorectal cancer with test positive subjects being referred to colonoscopy.
Trinh, Tony W; Glazer, Daniel I; Sadow, Cheryl A; Sahni, V Anik; Geller, Nina L; Silverman, Stuart G
2018-03-01
To determine test characteristics of CT urography for detecting bladder cancer in patients with hematuria and those undergoing surveillance, and to analyze reasons for false-positive and false-negative results. A HIPAA-compliant, IRB-approved retrospective review of reports from 1623 CT urograms between 10/2010 and 12/31/2013 was performed. 710 examinations for hematuria or bladder cancer history were compared to cystoscopy performed within 6 months. Reference standard was surgical pathology or 1-year minimum clinical follow-up. False-positive and false-negative examinations were reviewed to determine reasons for errors. Ninety-five bladder cancers were detected. CT urography accuracy: was 91.5% (650/710), sensitivity 86.3% (82/95), specificity 92.4% (568/615), positive predictive value 63.6% (82/129), and negative predictive value was 97.8% (568/581). Of 43 false positives, the majority of interpretation errors were due to benign prostatic hyperplasia (n = 12), trabeculated bladder (n = 9), and treatment changes (n = 8). Other causes include blood clots, mistaken normal anatomy, infectious/inflammatory changes, or had no cystoscopic correlate. Of 13 false negatives, 11 were due to technique, one to a large urinary residual, one to artifact. There were no errors in perception. CT urography is an accurate test for diagnosing bladder cancer; however, in protocols relying predominantly on excretory phase images, overall sensitivity remains insufficient to obviate cystoscopy. Awareness of bladder cancer mimics may reduce false-positive results. Improvements in CTU technique may reduce false-negative results.
False-negative syphilis treponemal enzyme immunoassay results in an HIV-infected case-patient.
Katz, Alan R; Komeya, Alan Y; Tomas, Juval E
2017-06-01
We present a case report of a false-negative syphilis treponemal enzyme immunoassay test result in an HIV-infected male. While treponemal tests are widely considered to be more sensitive and specific than non-treponemal tests, our findings point to potential challenges using the reverse sequence syphilis screening algorithm.
Hydrogen breath test in schoolchildren.
Douwes, A C; Schaap, C; van der Klei-van Moorsel, J M
1985-01-01
The frequency of negative hydrogen breath tests due to colonic bacterial flora which are unable to produce hydrogen was determined after oral lactulose challenge in 98 healthy Dutch schoolchildren. There was a negative result in 9.2%. The probability of a false normal lactose breath test (1:77) was calculated from these results together with those from a separate group of children with lactose malabsorption (also determined by hydrogen breath test). A study of siblings and mothers of subjects with a negative breath test did not show familial clustering of this condition. Faecal incubation tests with various sugars showed an increase in breath hydrogen greater than 100 parts per million in those with a positive breath test while subjects with a negative breath test also had a negative faecal incubation test. The frequency of a false negative hydrogen breath test was higher than previously reported, but this does not affect the superiority of this method of testing over the conventional blood glucose determination. PMID:4004310
... including physical and emotional problems. False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...
... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...
Negative feedback from maternal signals reduces false alarms by collectively signalling offspring.
Hamel, Jennifer A; Cocroft, Reginald B
2012-09-22
Within animal groups, individuals can learn of a predator's approach by attending to the behaviour of others. This use of social information increases an individual's perceptual range, but can also lead to the propagation of false alarms. Error copying is especially likely in species that signal collectively, because the coordination required for collective displays relies heavily on social information. Recent evidence suggests that collective behaviour in animals is, in part, regulated by negative feedback. Negative feedback may reduce false alarms by collectively signalling animals, but this possibility has not yet been tested. We tested the hypothesis that negative feedback increases the accuracy of collective signalling by reducing the production of false alarms. In the treehopper Umbonia crassicornis, clustered offspring produce collective signals during predator attacks, advertising the predator's location to the defending mother. Mothers signal after evicting the predator, and we show that this maternal communication reduces false alarms by offspring. We suggest that maternal signals elevate offspring signalling thresholds. This is, to our knowledge, the first study to show that negative feedback can reduce false alarms by collectively behaving groups.
van der Meulen, Miriam P; Lansdorp-Vogelaar, Iris; van Heijningen, Else-Mariëtte B; Kuipers, Ernst J; van Ballegooijen, Marjolein
2016-06-01
If some adenomas do not bleed over several years, they will cause systematic false-negative fecal immunochemical test (FIT) results. The long-term effectiveness of FIT screening has been estimated without accounting for such systematic false-negativity. There are now data with which to evaluate this issue. The authors developed one microsimulation model (MISCAN [MIcrosimulation SCreening ANalysis]-Colon) without systematic false-negative FIT results and one model that allowed a percentage of adenomas to be systematically missed in successive FIT screening rounds. Both variants were adjusted to reproduce the first-round findings of the Dutch CORERO FIT screening trial. The authors then compared simulated detection rates in the second screening round with those observed, and adjusted the simulated percentage of systematically missed adenomas to those data. Finally, the authors calculated the impact of systematic false-negative FIT results on the effectiveness of repeated FIT screening. The model without systematic false-negativity simulated higher detection rates in the second screening round than observed. These observed rates could be reproduced when assuming that FIT systematically missed 26% of advanced and 73% of nonadvanced adenomas. To reduce the false-positive rate in the second round to the observed level, the authors also had to assume that 30% of false-positive findings were systematically false-positive. Systematic false-negative FIT testing limits the long-term reduction of biennial FIT screening in the incidence of colorectal cancer (35.6% vs 40.9%) and its mortality (55.2% vs 59.0%) in participants. The results of the current study provide convincing evidence based on the combination of real-life and modeling data that a percentage of adenomas are systematically missed by repeat FIT screening. This impairs the efficacy of FIT screening. Cancer 2016;122:1680-8. © 2016 American Cancer Society. © 2016 American Cancer Society.
Risks of Skin Cancer Screening
... may have serious side effects . False-negative test results can occur. Screening test results may appear to ... even if there are symptoms. False-positive test results can occur. Screening test results may appear to ...
Modified Test Protocol Improves Sensitivity of the Stereo Fly Test.
De La Cruz, Angie; Morale, Sarah E; Jost, Reed M; Kelly, Krista R; Birch, Eileen E
2016-01-01
Stereoacuity measurement is a common element of pediatric ophthalmic examinations. Although the Stereo Fly Test is routinely used to establish the presence of coarse stereopsis (3000 arcsecs), it often yields a false negative "pass" due to learned responses and non-stereoscopic cues. We developed and evaluated a modified Stereo Fly Test protocol aimed at increasing sensitivity, thus reducing false negatives. The Stereo Fly Test was administered according to manufacturer instructions to 321 children aged 3-12 years. Children with a "pass" outcome (n = 147) were re-tested wearing glasses fitted with polarizers of matching orientation for both eyes to verify that they were responding to stereoscopic cues (modified protocol). The response to the standard Stereo Fly Test was considered a false negative (pass) if the child still pinched above the plate after disparity cues were eliminated. Randot ® Preschool Stereoacuity and Butterfly Tests were used as gold standards. Sensitivity was 81% (95% CI: 0.75 - 0.86) for standard administration of the Stereo Fly Test (19% false negative "pass"). The modified protocol increased sensitivity to 90% (95% CI: 0.85 - 0.94). The modified two-step protocol is a simple and convenient way to administer the Stereo Fly Test with increased sensitivity in a clinical setting. © 2016 Board of regents of the University of Wisconsin System, American Orthoptic Journal, Volume 66, 2016, ISSN 0065-955X, E-ISSN 1553-4448.
Frequency of false-negative reactions to the fragrance mix.
de Groot, A C; van der Kley, A M; Bruynzeel, D P; Meinardi, M M; Smeenk, G; van Joost, T; Pavel, S
1993-03-01
To estimate the frequency of false-negative reactions to the fragrance mix, the 8 constituents of the mix in concentrations of 5% (2% for cinnamic aldehyde) were added to the European standard series for routine testing. Patients with positive reactions to individual ingredients in the absence of a reaction to the mix were retested with serial dilutions. In a 4-month period, 677 patients were tested. 61 (9%) reacted to the mix and to 1 or more of the ingredients. 4 patients (0.6% of all patients tested and 6.2% of the patients allergic to fragrances) had false-negative reactions to the mix. They were allergic to cinnamic alcohol, geraniol, isoeugenol and oak moss (1 reaction each), in the absence of a reaction to the fragrance mix. It is concluded that the currently used concentration of the mix (8 x 1%) not infrequently results in false-negative reactions, and that further research should be done to overcome this problem.
False negative rates in Drosophila cell-based RNAi screens: a case study
2011-01-01
Background High-throughput screening using RNAi is a powerful gene discovery method but is often complicated by false positive and false negative results. Whereas false positive results associated with RNAi reagents has been a matter of extensive study, the issue of false negatives has received less attention. Results We performed a meta-analysis of several genome-wide, cell-based Drosophila RNAi screens, together with a more focused RNAi screen, and conclude that the rate of false negative results is at least 8%. Further, we demonstrate how knowledge of the cell transcriptome can be used to resolve ambiguous results and how the number of false negative results can be reduced by using multiple, independently-tested RNAi reagents per gene. Conclusions RNAi reagents that target the same gene do not always yield consistent results due to false positives and weak or ineffective reagents. False positive results can be partially minimized by filtering with transcriptome data. RNAi libraries with multiple reagents per gene also reduce false positive and false negative outcomes when inconsistent results are disambiguated carefully. PMID:21251254
Tetteh, Ato Kwamena; Agyarko, Edward
2017-01-01
Screening results of 488 pregnant women aged 15-44 years whose blood samples had been tested on-site, using First Response® HIV 1/2, and confirmed with INNO-LIA™ HIV I/II Score were used. Of this total, 178 were reactive (HIV I, 154; HIV II, 2; and HIV I and HIV II, 22). Of the 154 HIV I-reactive samples, 104 were confirmed to be HIV I-positive and 2 were confirmed to be HIV II-positive, while 48 were confirmed to be negative [false positive rate = 17.44% (13.56-21.32)]. The two HIV II samples submitted were confirmed to be negative with the confirmatory test. For the 22 HIV I and HIV II samples, 7 were confirmed to be HIV I-positive and 1 was confirmed to be HIV I- and HIV II-positive, while 14 were confirmed to be negative. Of the 310 nonreactive samples, 6 were confirmed to be HIV I-positive and 1 was confirmed to be HIV II-positive [false negative rate = 5.79% (1.63-8.38)], while 303 were negative. False negative outcomes will remain unconfirmed, with no management options for the client. False negative rate of 5.79% requires attention, as its resultant implications on control of HIV/AIDS could be dire.
Paek, Se Hyun; Kim, Byung Seup; Kang, Kyung Ho; Kim, Hee Sung
2017-11-13
The BRAF V600E mutation is highly specific for papillary thyroid carcinoma (PTC). A test for this mutation can increase the diagnostic accuracy of fine-needle aspiration cytology (FNAC), but a considerably high false-negative rate for the BRAF V600E mutation on FNAC has been reported. In this study, we investigated the risk factors associated with false-negative BRAF V600E mutation results on FNAC. BRAF V600E mutation results of 221 PTC nodules between December 2011 and June 2013 were retrospectively reviewed. BRAF V600E mutation results on both preoperative FNAC and postoperative formalin-fixed, paraffin-embedded (FFPE) samples were compared. We investigated the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of BRAF V600E mutation results on FNAC. And, we identified the risk factors associated with false-negative results. Of 221 PTC nodules, 150 (67.9%) on FNAC and 185 (83.7%) on FFPE samples were BRAF V600E mutation positive. The sensitivity, specificity, PPV, and NPV for BRAF V600E mutation testing with FNAC were 80.5, 97.2, 99.3, and 49.3%, respectively. Thirty-six (16.3%) BRAF V600E mutation-negative nodules on FNAC were mutation positive on FFPE sample analysis. Risk factors for these false-negative results were age, indeterminate FNAC results (nondiagnostic, atypia of undetermined significance (AUS), and findings suspicious for PTC), and PTC subtype. False-negative rate of BRAF mutation testing with FNAC for thyroid nodules is increased in cases of old age, indeterminate FNAC pathology results, and certain PTC subtypes. Therapeutic surgery can be considered for these cases. A well-designed prospective study with informed consent of patients will be essential for more informative results.
Castelló, Ana; Francès, Francesc; Verdú, Fernando
2017-09-01
Presumptive tests for blood are very simple and sensitive tests used in the search for evidence. They also provide initial information on the nature of stains. A second test can confirm their nature. However, these tests can present false-negative results for different reasons. Some of those reasons have been studied, while others, those caused by the substrate material that contains the stain, are less well known. This work studies the effect of one component of a leather substrate-quebracho extract-on presumptive and human hemoglobin blood tests. Assays were performed using samples of blood dilutions contaminated with quebracho extract and others formed on a substrate containing the contaminant. Results show an undoubted interference that causes false negatives and even visible to the naked eye stains and also indicate that some tests (phenolphthalein) are more affected than others. Examiners should be taken into account when working on this kind of substrates. © 2017 American Academy of Forensic Sciences.
The role of attention at retrieval on the false recognition of negative emotional DRM lists.
Shah, Datin; Knott, Lauren M
2018-02-01
This study examined the role of attention at retrieval on the false recognition of emotional items using the Deese-Roediger-McDermott (DRM) paradigm. Previous research has shown that divided attention at test increases false remember judgements for neutral critical lures. However, no research has yet directly assessed emotional false memories when attention is manipulated at retrieval. To examine this, participants studied negative (low in valence and high in arousal) and neutral DRM lists and completed recognition tests under conditions of full and divided attention. Results revealed that divided attention at retrieval increased false remember judgements for all critical lures compared to retrieval under full attention, but in both retrieval conditions, false memories were greater for negative compared to neutral stimuli. We believe that this is due to reliance on a more easily accessible (meaning of the word) but less diagnostic form of source monitoring, amplified under conditions of divided attention.
Half, Elizabeth E; Mlynarsky, Liat; Naftali, Timna; Benjaminov, Fabiana; Konikoff, Fred M
2013-09-01
Fecal Occult Blood Test (FOBT) is an accepted screening test for colorectal cancer (CRC). It has been shown to decrease mortality by up to 30%. The outcome of screening failures has not been adequately studied. The purpose of this study was to assess the outcome of patients who were diagnosed with CRC after a false negative FOBT. We identified all consecutive CRCs from pathology reports between 2005 and 2010. Patients were divided according to their FOBT result. Those who became positive were compared to patients who remained negative. Altogether 401 CRCs were identified. Of those, 202 never performed a FOBT. At least one negative FOBT was performed by 133 individuals (67%). Of these, 76 remained negative (false negatives, FN) and 57 became positive (positive conversion, PC, controls). The prevalence of metastatic disease was threefold higher among the FNs as compared to the PC group (16 [22.2%] vs. 4 [7.5%], P=0.022). All-cause mortality was also significantly higher among FNs versus PCs (24 [31.6%] vs. 5 [8.8%], P=0.001); in Cox regression analysis of survival (covariates: FNs vs. PC, gender, age, medications and co-morbidities) FNs had increased mortality compared to the PC (HR 2.929, P=0.033, CI 95% 1.092-7.858). No statistically significant difference was found regarding all primary end points when comparing the FN and the "No test" group. These data disclose a particular risk of FOBT as a screening test. A subgroup of patients with "false" negative tests may have increased morbidity and mortality. Efforts should be made to recognize and characterize this high-risk group.
Lin, Karl K; Rahman, Mohammad A
2018-05-21
Interest has been expressed in using a joint test procedure that requires that the results of both a trend test and a pairwise comparison test between the control and the high groups be statistically significant simultaneously at the levels of significance recommended in the FDA 2001 draft guidance for industry document for the separate tests in order for the drug effect on the development of an individual tumor type to be considered as statistically significant. Results of our simulation studies show that there is a serious consequence of large inflations of the false negative rate through large decreases of false positive rate in the use of the above joint test procedure in the final interpretation of the carcinogenicity potential of a new drug if the levels of significance recommended for separate tests are used. The inflation can be as high as 204.5% of the false negative rate when the trend test alone is required to test if the effect is statistically significant. To correct the problem, new sets of levels of significance have also been developed for those who want to use the joint test in reviews of carcinogenicity studies.
Johnson, Cheryl C.; Fonner, Virginia; Sands, Anita; Ford, Nathan; Obermeyer, Carla Mahklouf; Tsui, Sharon; Wong, Vincent; Baggaley, Rachel
2017-01-01
Abstract Introduction: In accordance with global testing and treatment targets, many countries are seeking ways to reach the “90-90-90” goals, starting with diagnosing 90% of all people with HIV. Quality HIV testing services are needed to enable people with HIV to be diagnosed and linked to treatment as early as possible. It is essential that opportunities to reach people with undiagnosed HIV are not missed, diagnoses are correct and HIV-negative individuals are not inadvertently initiated on life-long treatment. We conducted this systematic review to assess the magnitude of misdiagnosis and to describe poor HIV testing practices using rapid diagnostic tests. Methods: We systematically searched peer-reviewed articles, abstracts and grey literature published from 1 January 1990 to 19 April 2017. Studies were included if they used at least two rapid diagnostic tests and reported on HIV misdiagnosis, factors related to potential misdiagnosis or described quality issues and errors related to HIV testing. Results: Sixty-four studies were included in this review. A small proportion of false positive (median 3.1%, interquartile range (IQR): 0.4-5.2%) and false negative (median: 0.4%, IQR: 0-3.9%) diagnoses were identified. Suboptimal testing strategies were the most common factor in studies reporting misdiagnoses, particularly false positive diagnoses due to using a “tiebreaker” test to resolve discrepant test results. A substantial proportion of false negative diagnoses were related to retesting among people on antiretroviral therapy. Conclusions: HIV testing errors and poor practices, particularly those resulting in false positive or false negative diagnoses, do occur but are preventable. Efforts to accelerate HIV diagnosis and linkage to treatment should be complemented by efforts to improve the quality of HIV testing services and strengthen the quality management systems, particularly the use of validated testing algorithms and strategies, retesting people diagnosed with HIV before initiating treatment and providing clear messages to people with HIV on treatment on the risk of a “false negative” test result. PMID:28872271
Nemoto, Kenji; Oh-ishi, Shuji; Taguchi, Masato; Hyodo, Kentaro; Kanazawa, Jun; Miura, Yukiko; Takaku, Takio; Usui, Shingo; Hayashihara, Kenji; Saito, Takefumi
2016-04-01
T-SPOT.TB (T-SPOT), an interferon-gamma release assay, has shown promise as a diagnostic tool for active tuberculosis (TB), and its use is expanding. Addition of the T-Cell Xtend (TCX) reagent may allow delayed processing, and this characteristic is important for using this test in the field. However, limited data is available on the usefulness of T-SPOT with TCX as a field test for diagnosing active TB. To investigate the clinical utility of T-SPOT with TCX and the risk factors for a false-negative result in patients with active TB. A total of 57 patients with active TB who underwent the T-SPOT test with TCX prior to treatment were enrolled between May 2013 and May 2015. One patient with an indeterminate result for T-SPOT was excluded; therefore, the data of 56 patients were eventually included in the final analysis. The basic characteristics and clinical findings were compared between the true-positive and false-negative T-SPOT groups. Of the 56 patients, 40 (71.4%), 13 (23.2%), 3 (5.4%) had true-positive, false-negative, and borderline T-SPOT results, respectively. This study did not reveal any significant risk factors for a false-negative T-SPOT result. In this clinical study, the proportion of patients with a false-negative result for T-SPOT with TCX for active TB was higher than that reported previously. Therefore, careful interpretation of a negative result for T-SPOT with TCX is necessary, regardless of the patient's background.
Navabi, Nazlee; Montebatsi, Milton; Scott, Michelle; Gluckman, Stephen J; Reid, Michael J A
2015-01-01
A case of false-negative serum latex agglutination cryptococcal antigen (CRAG) test in a 45-year-old HIV-positive male with Cryptococcus-positive culture is described. The patient was presented to a hospital in Botswana, with breathlessness and a diffuse papular rash. His CD4 count was 25 cells/μL. Despite the suspicion for disseminated cryptococcal disease, an initial serum CRAG latex test was negative. Results of subsequent Indian ink staining, culture of cerebrospinal fluid and skin scrapings, and serum lateral flow immunoassay (LFA) were all positive for Cryptococcus neoformans. There are several possible explanations for the false-negative CRAG latex test. Given the positive LFA result, we speculate that disease may have been caused by Cryptococcus gattii, which is estimated to be responsible for between 15% and 30% of all cryptococcal diseases in Botswana. Reduced sensitivity of CRAG latex assays for detecting C gattii may lead to underdiagnosis of cryptococcal infection. © The Author(s) 2014.
Won, Kyu-Hee; Lee, Jae Yeon; Cho, Hye-Yon; Suh, Dong Hoon; No, Jae Hong; Kim, Yong-Beom
2015-03-01
Human papillomavirus (HPV) test was incorporated into the triage of lesser abnormal cervical cytologies: atypical squamous cells of undetermined significance (ASCUS) or low-grade squamous intraepithelial lesion (LSIL). This study aimed to evaluate the impact of age on the efficacy of HPV testing in patients with lesser abnormal cervical cytologies. A total of 439 patients with ASCUS or LSIL were included. The association between age groups and the diagnostic performances of HPV test for high-grade cervical intraepithelial neoplasia (CIN2+) was evaluated. Median age was 44 years (range, 17 to 75 years). ASCUS was more frequently observed in older patients while LSIL was more common in younger patients (P=0.002). CIN2+ was found in 11.3% (32/284) of the ASCUS patients and 12.9% (20/155) of patients with LSIL. Older patients with ASCUS showed lower HPV infection rates (P=0.025), but not LSIL (P=0.114). However, the prevalence of CIN2+ was similar between the age groups with ASCUS or LSIL. In patients with ASCUS, the false negative rate of HPV test for CIN2+ was 6.2%. The false negative rate of the HPV test became higher with increasing of the age after the age of 50 (P=0.034). Our findings suggest that false negative rate of the HPV test for CIN2+ in ASCUS patients older than 50 years might become higher with increasing of the age. Negative HPV results in patients of the age >50 years with ASCUS should be carefully interpreted.
Ferreira, Bruno G.; Falcioni, Renan; Guedes, Lubia M.; Avritzer, Sofia C.; Antunes, Werner C.; Souza, Luiz A.; Isaias, Rosy M.S.
2016-01-01
Polyethylene glycol (PEG) is a low-cost and advantageous embedding medium, which maintains the majority of cell contents unaltered during the embedding process. Some hard or complex plant materials are better embedded in PEG than in other usual embedding media. However, the histochemical tests for phenolics and lignins in PEG-embedded plant tissues commonly result in false negatives. We hypothesize that these false negatives should be prevented by the use of distinct fixatives, which should avoid the bonds between PEG and phenols. Novel protocols for phenolics and flavanols detection are efficiently tested, with fixation of the samples in ferrous sulfate and formalin or in caffeine and sodium benzoate, respectively. The differentiation of lignin types is possible in safranin-stained sections observed under fluorescence. The Maule’s test faultlessly distinguishes syringyl-rich from guaiacyl- and hydroxyphenyl-rich lignins in PEG-embedded material under light microscopy. Current hypothesis is corroborated, that is, the adequate fixation solves the false-negative results, and the new proposed protocols fill up some gaps on the detection of phenolics and lignins. PMID:28117630
Prenatal Genetic Screening Tests
... information about the rates of false-positive and false-negative results for each test. What should I consider when deciding whether to have prenatal genetic testing? It is your choice whether to have prenatal testing. Your personal beliefs and values are important factors in the decision ...
Zhang, Jingyang; Chaloner, Kathryn; McLinden, James H.; Stapleton, Jack T.
2013-01-01
Reconciling two quantitative ELISA tests for an antibody to an RNA virus, in a situation without a gold standard and where false negatives may occur, is the motivation for this work. False negatives occur when access of the antibody to the binding site is blocked. Based on the mechanism of the assay, a mixture of four bivariate normal distributions is proposed with the mixture probabilities depending on a two-stage latent variable model including the prevalence of the antibody in the population and the probabilities of blocking on each test. There is prior information on the prevalence of the antibody, and also on the probability of false negatives, and so a Bayesian analysis is used. The dependence between the two tests is modeled to be consistent with the biological mechanism. Bayesian decision theory is utilized for classification. The proposed method is applied to the motivating data set to classify the data into two groups: those with and those without the antibody. Simulation studies describe the properties of the estimation and the classification. Sensitivity to the choice of the prior distribution is also addressed by simulation. The same model with two levels of latent variables is applicable in other testing procedures such as quantitative polymerase chain reaction tests where false negatives occur when there is a mutation in the primer sequence. PMID:23592433
... rule out a possible false-negative result. Normal Results A negative or nonreactive result means that you ... meaning of your specific test results. What Abnormal Results Mean A positive FTA-ABS is often a ...
Reducing false negatives in clinical practice: the role of neural network technology.
Mango, L J
1996-10-01
The fact that some cervical smears result in false-negative findings is an unavoidable and unpredictable consequence of the conventional (manual microscopic) method of screening. Errors in the detection and interpretation of abnormality are cited as leading causes of false-negative cytology findings; these are random errors that are not known to correlate with any patient risk factor, which makes the false-negative findings a "silent" threat that is difficult to prevent. Described by many as a labor-intensive procedure, the microscopic evaluation of a cervical smear involves a detailed search among hundreds of thousands of cells on each smear for a possible few that may indicate abnormality. Investigations into causes of false-negative findings preceding the discovery of high-grade lesions found that many smears had very few diagnostic cells that were often very small in size. These small cells were initially overlooked or misinterpreted and repeatedly missed on rescreening. PAPNET testing is designed to supplement conventional screening by detecting abnormal cells that initially may have been missed by microscopic examination. This interactive system uses neural networks, a type of artificial intelligence well suited for pattern recognition, to automate the arduous search for abnormality. The instrument focuses the review of suspicious cells by a trained cytologist. Clinical studies indicate that PAPNET testing is sensitive to abnormality typically missed by conventional screening and that its use as a supplemental test improves the accuracy of screening.
Johnson, Susan L; Tabaei, Bahman P; Herman, William H
2005-02-01
To simulate the outcomes of alternative strategies for screening the U.S. population 45-74 years of age for type 2 diabetes. We simulated screening with random plasma glucose (RPG) and cut points of 100, 130, and 160 mg/dl and a multivariate equation including RPG and other variables. Over 15 years, we simulated screening at intervals of 1, 3, and 5 years. All positive screening tests were followed by a diagnostic fasting plasma glucose or an oral glucose tolerance test. Outcomes include the numbers of false-negative, true-positive, and false-positive screening tests and the direct and indirect costs. At year 15, screening every 3 years with an RPG cut point of 100 mg/dl left 0.2 million false negatives, an RPG of 130 mg/dl or the equation left 1.3 million false negatives, and an RPG of 160 mg/dl left 2.8 million false negatives. Over 15 years, the absolute difference between the most sensitive and most specific screening strategy was 4.5 million true positives and 476 million false-positives. Strategies using RPG cut points of 130 mg/dl or the multivariate equation every 3 years identified 17.3 million true positives; however, the equation identified fewer false-positives. The total cost of the most sensitive screening strategy was $42.7 billion and that of the most specific strategy was $6.9 billion. Screening for type 2 diabetes every 3 years with an RPG cut point of 130 mg/dl or the multivariate equation provides good yield and minimizes false-positive screening tests and costs.
A case of placental trisomy 18 mosaicism causing a false negative NIPT result.
Yang, Jiexia; Qi, Yiming; Guo, Fangfang; Hou, Yaping; Peng, Haishan; Wang, Dongmei; Oy, Haoxin; Yin, Aihua
2017-01-01
The non-invasive prenatal testing that evaluates circulating cell free DNA, and has been established as an additional pregnancy test for detecting the common fetal trisomies 21, 18 and 13 is rapidly revolutionizing prenatal screening as a result of its increased sensitivity and specificity. However, false positive and false negative results still exist. We presented a case in which the non-invasive prenatal testing results were normal at 15 gestational age (GA), but an ultrasound examination at 30GA showed that the fetus had heart abnormalities, and the third trimester ultrasound at 33GA noted multiple anomalies including a 3.0 mm ventricular septal defect. Along with cordocentesis at 33GA, the cord blood sample cytogenetics analysis showed a mos 47,XN,+18[61]/46,XN[39] T18 karyotype. Six placental biopsies confirmed that the chromosome 18 placenta chimerism ratio had changed from 33% to 72%. Ultimately, the pregnancy was interrupted at 34GA. We presented this case to highlight the need to clearly explain false positive or false negative results to patients. We believe that this information will also influence the development of future diagnostic test methodologies.
Predicting the carcinogenicity of chemicals with alternative approaches: recent advances.
Benigni, Romualdo
2014-09-01
Alternative approaches to the rodent bioassay are necessary for early identification of problematic drugs and biocides during the development process, and are the only practicable tool for assessing environmental chemicals with no or adequate safety documentation. This review informs on: i) the traditional prescreening through genotoxicity testing; ii) an integrative approach that assesses DNA-reactivity and ability to disorganize tissues; iii) new applications of omics technologies (ToxCast/Tox21 project); iv) a pragmatic approach aimed at filling data gaps by intrapolating/extrapolating from similar chemicals (read-across, category formation). The review also approaches the issue of the concerns about false-positive and false-negative results that prevents a wider acceptance and use of alternatives. The review addresses strengths and limitations of various proposals, and concludes on the need of differential approaches to the issue of false negatives and false positives. False negatives can be eliminated or reduced below the variability of the animal assay with conservative quantitative structure-activity relationships or in vitro tests; false positives can be cleared with ad hoc mechanistically based follow-ups. This framework can permit a reduction of animal testing and a better protection of human health.
Strep Test: Rapid (For Parents)
... third of negative rapid strep test results are false (meaning someone actually has a strep throat infection even though the rapid strep results were negative). A throat culture may then be done to ensure accuracy. Risks ...
Gestational Trophoblastic Disease Diagnosis Delayed by the Hook Effect.
Cormano, Julia; Mackay, Gillian; Holschneider, Christine
2015-10-01
A "hook effect" resulting from saturation of antibodies used in pregnancy tests can occur at human chorionic gonadotropin (hCG) levels above 500,000 milliinternational units/mL, resulting in falsely negative values. A 34-year-old woman, gravida 5 para 3, presented to the emergency department after heavy bleeding. Ultrasonogram revealed a uterine mass, urine pregnancy test result was negative, and endometrial biopsy inconclusive. The patient was discharged and presented 10 days later with recurrent bleeding. Urine pregnancy test result was again negative, but serum hCG was 581 milliinternational units/mL. Serial dilution revealed an actual hCG higher than 5 million milliinternational units/mL. She was diagnosed with gestational trophoblastic disease. Awareness of the risk of a false-negative pregnancy test result when hCG levels are extremely high may prevent delayed diagnosis of gestational trophoblastic disease.
Mood-congruent false memories persist over time.
Knott, Lauren M; Thorley, Craig
2014-01-01
In this study, we examined the role of mood-congruency and retention interval on the false recognition of emotion laden items using the Deese/Roediger-McDermott (DRM) paradigm. Previous research has shown a mood-congruent false memory enhancement during immediate recognition tasks. The present study examined the persistence of this effect following a one-week delay. Participants were placed in a negative or neutral mood, presented with negative-emotion and neutral-emotion DRM word lists, and administered with both immediate and delayed recognition tests. Results showed that a negative mood state increased remember judgments for negative-emotion critical lures, in comparison to neutral-emotion critical lures, on both immediate and delayed testing. These findings are discussed in relation to theories of spreading activation and emotion-enhanced memory, with consideration of the applied forensic implications of such findings.
Skin testing for immediate hypersensitivity to corticosteroids: a case series and literature review.
Baker, A; Empson, M; The, R; Fitzharris, P
2015-03-01
Immediate hypersensitivity to corticosteroids is reported to occur with an incidence of 0.1%. The largest previous case series reporting corticosteroid skin testing has seven patients. We identified 23 patients (mean age 50 years, 65% female) from Auckland City Hospital who underwent skin testing (ST) for suspected corticosteroid hypersensitivity between July 2005 and April 2012. We performed a retrospective clinical case note review detailing clinical history of reaction, skin test results and subsequent management. Most patients (21/23) had a standard panel of testing with prednisolone, triamcinolone, methylprednisolone, hydrocortisone and dexamethasone. Skin tests used a 10% steroid stock concentration for skin prick tests (SPT) and dilutions of 1 : 1000, 1 : 100 and 1 : 10 for subsequent intradermal testing. A weal 3 mm greater than the negative control was considered positive. A total of 23 patients were identified who had skin testing for suspected acute hypersensitivity to corticosteroids, eight of which had a history of anaphylaxis. From 28 reactions (in 23 patients), the most common route of administration was intra-articular (13), followed by oral (7), intravenous (3) and other (5). Skin tests were positive in 8/23 patients, and 7/8 of these patients had a history of corticosteroid-associated anaphylaxis. Skin tests were positive at either the skin prick test or intradermal stages. There was evidence suggesting clinical and skin test cross-reactivity between corticosteroids in one patient. One patient had a positive skin test, but negative oral challenge suggesting the skin test was false positive. Skin tests were negative in 15/23 patients. One patient had a negative prednisolone skin test and positive unblinded oral challenge, suggesting a false-negative skin test. Skin testing can provide sufficient evidence to diagnose allergy in patients with a clear history of immediate hypersensitivity to corticosteroids such as anaphylaxis. Both skin prick and intradermal tests should be used. There is evidence of cross-reactivity between steroids, so a panel is recommended. False-positive and false-negative reactions do occur; however, the frequency is unknown. Challenge remains the only definitive way to demonstrate a safe alternative to use. As the largest case series described, this article provides new evidence for the interpretation of skin tests when investigating possible immediate hypersensitivity to corticosteroids. © 2014 John Wiley & Sons Ltd.
Potential for false positive HIV test results with the serial rapid HIV testing algorithm.
Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K
2012-03-19
Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.
Potential for false positive HIV test results with the serial rapid HIV testing algorithm
2012-01-01
Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals. PMID:22429706
Are overreferrals on developmental screening tests really a problem?
Glascoe, F P
2001-01-01
Developmental screening tests, even those meeting standards for screening test accuracy, produce numerous false-positive results for 15% to 30% of children. This is thought to produce unnecessary referrals for diagnostic testing or special services and increase the cost of screening programs. To explore whether children who pass screening tests differ in important ways from those who do not and to determine whether children overreferred for testing benefit from the scrutiny of diagnostic testing and treatment planning. Subjects were a national sample of 512 parents and their children (age range of the children, 7 months to 8 years) who participated in validation studies of various screening tests. Psychological examiners adhering to standardized directions obtained informed consent and administered at least 2 developmental screening measures (the Brigance Screens, the Battelle Developmental Inventory Screening Test, the Denver-II, and the Parents' Evaluations of Developmental Status) and a concurrent battery of diagnostic measures, including tests of intelligence, language, and academic achievement (for children aged 2(1/2) years and older). The performance on diagnostic measures of children who failed screening but were not found to have a disability (false positives) was compared with that of children who passed screening and did not have a disability on diagnostic testing (true negatives). Children with false-positive scores performed significantly (P<.001) lower on diagnostic measures than did children with true-negative scores. The false-positive group had scores in adaptive behavior, language, intelligence, and academic achievement that were 9 to 14 points lower than the scores of those in the true-negative group. When viewing the likelihood of scoring below the 25th percentile on diagnostic measures, children with false-positive scores had a relative risk of 2.6 in adaptive behavior (95% confidence interval [CI], 1.67-4.21), 3.1 in language skills (95% CI, 1.90-5.20), 6.7 on intelligence tests (95% CI, 3.28-13.50), and 4.9 on academic measures (95% CI, 2.61-9.28). Overall, 151 (70%) of the children with false-positive results scored below the 25th percentile on 1 or more diagnostic measures (the point at which most children have difficulty benefiting from typical classroom instruction) in contrast with 64 (29%) of the children with true-negative scores (odds ratio, 5.6; 95% CI, 3.73-8.49). Children with false-positive scores were also more likely to be nonwhite and to have parents who had not graduated from high school. Performance differences between children with true-negative scores and children with false-positive scores continued to be significant (P<.001) even after adjusting for sociodemographic differences between groups. Children overreferred for diagnostic testing by developmental screens perform substantially lower than children with true-negative scores on measures of intelligence, language, and academic achievement-the 3 best predictors of school success. These children also carry more psychosocial risk factors, such as limited parental education and minority status. Thus, children with false-positive screening results are an at-risk group for whom diagnostic testing may not be an unnecessary expense but rather a beneficial and needed service that can help focus intervention efforts. Although such testing will not indicate a need for special education placement, it can be useful in identifying children's needs for other programs known to improve language, cognitive, and academic skills, such as Head Start, Title I services, tutoring, private speech-language therapy, and quality day care.
Detection of CIN by naked eye visualization after application of acetic acid.
Londhe, M; George, S S; Seshadri, L
1997-06-01
A prospective study was undertaken to determine the sensitivity and specificity of acetic application to the cervix followed by naked eye visualization as a screening test for detection of cervical intraepithelial neoplasia. Three hundred and seventy two sexually active woman in the reproductive age group were studied. All the women underwent Papanicolaou test, acetic acid test and colposcopy. One hundred and seventy five woman were acetic acid test negative, 197 women were acetic acid test positive. The sensitivity of acetic acid test was 72.4%, specificity 54% and false negative rate 15.2%, as compared to papanicolaou test which had a sensitivity of 13.2%, specificity of 96.3% and false negative rate of 24.4%. The advantage of the acetic acid test lies in its easy technique, low cost and high sensitivity which are important factors for determining the efficacy of any screening programme in developing countries.
Parry, John V; Easterbrook, Philippa; Sands, Anita R
2017-11-01
Initial serological testing for chronic hepatitis B virus (HBV) and hepatitis C virus (HCV) infection is conducted using either rapid diagnostic tests (RDT) or laboratory-based enzyme immunoassays (EIA)s for detection of hepatitis B surface antigen (HBsAg) or antibodies to HCV (anti-HCV), typically on serum or plasma specimens and, for certain RDTs, capillary whole blood. WHO recommends the use of standardized testing strategies - defined as a sequence of one or more assays to maximize testing accuracy while simplifying the testing process and ideally minimizing cost. Our objective was to examine the diagnostic outcomes of a one- versus two-assay serological testing strategy. These data were used to inform recommendations in the 2017 WHO Guidelines on hepatitis B and C testing. Few published studies have compared diagnostic outcomes for one-assay versus two-assay serological testing strategies for HBsAg and anti-HCV. Therefore, the principles of Bayesian statistics were used to conduct a modelling exercise to examine the outcomes of a one-assay versus two-assay testing strategy when applied to a hypothetical population of 10,000 individuals. The resulting model examined the diagnostic outcomes (true and false positive diagnoses; true and false negative diagnoses; positive and negative predictive values as a function of prevalence; and total tests required) for both one-assay and two-assay testing strategies. The performance characteristics assumed for assays used within the testing strategies were informed by WHO prequalification assessment findings and systematic reviews for diagnostic accuracy studies. Each of the presumptive testing strategies (one-assay or two-assay) was modelled at varying prevalences of HBsAg (10%, 2% and 0.4%) and of anti-HCV (40%, 10%, 2% and 0.4%), aimed at representing the range of testing populations typically encountered in WHO Member States. When the two-assay testing strategy was considered, the model assumed the independence of the two assays. Modeling demonstrated that applying a single assay (HBsAg or anti-HCV), even with high specificity (99%), may result in considerable numbers of false positive diagnoses and low positive predictive values (PPV), particularly in lower prevalence settings. Even at very low prevalences shifting to a two-assay testing strategy would result in a PPV approaching 1.0. When test sensitivity is high (>99%) false negative reactions are rare at all but the highest prevalences; but a two-test strategy might yield more false negative diagnoses. The order in which the tests are used has no impact on the overall accuracy of a two-assay strategy though it may impact the total number of tests needed to complete the diagnostic strategy, incurring added cost and complexity. HBsAg assays may have a low sensitivity (<90%), and result in large numbers of false negative diagnoses, particularly in high prevalence settings, which would be exacerbated in the two-assay testing strategy. In contrast, most anti-HCV assays have high sensitivity and lead to fewer false negative results, both in the one-assay and two-assay testing strategies. At prevalences ≤2% the number of tests needed using a second assay was nearly always small, at <300 per 10,000 individuals tested, making sustainability of a second assay uncertain in such a setting. A key public health objective of an effective testing strategy is to identify all individuals who would benefit from treatment. Therefore, a strategy that prioritizes a high NPV (minimal false negatives) may be acceptable even if the PPV is suboptimal (some false positives) as the implementation of such a public health programme must also take account of other factors such as costs, feasibility, impact on testing uptake and linkage to care, and consequences of a false-positive test. This rationale informed the development of the WHO Viral Hepatitis Testing Guidelines, with a conditional recommendation for a one-assay serological testing strategy in most testing settings and populations (≥0.4% prevalence in population tested). A one-test strategy results in few failures to diagnose infection and, although it is associated under most assumptions with a sub-optimal PPV, benefits include greater simplicity, easier implementation, lower costs and better feasibility, uptake and linkage to care. Furthermore, prior to antiviral therapy all those diagnosed either HBsAg or anti-HCV positive will require confirmation of viræmia, preventing unnecessary treatment of those who may be false positive on serology. For HBsAg, in low-prevalence settings (≤0.4%), a second recommendation was made to consider a two-assay testing strategy, using a confirmatory neutralization step or a second different HBsAg assay.
Studies regarding the mechanism of false negative urea breath tests with proton pump inhibitors.
Graham, David Y; Opekun, Antone R; Hammoud, Fadi; Yamaoka, Yoshio; Reddy, Rita; Osato, Michael S; El-Zimaity, Hala M T
2003-05-01
The mechanism of false negative urea breath tests (UBTs) results among proton pump inhibitor (PPI) users is unknown. We studied the time course of PPI-associated negative UBT, the relation to Helicobacter pylori density, and whether gastric acidification would prevent false negative UBT results. In the UBT experiment, H. pylori-infected volunteers received omeprazole 20 mg b.i.d. for 13.5 days. UBTs with citric acid were done before, after 6.5 days of PPI, and 1, 2, 4, 7, and 14 days after therapy. In the culture and histology experiment, after a wash-out of >5 months, nine of the original subjects were rechallenged with omeprazole for 6.5 days. Antral and corpus biopsies for histology and culture were done before and 1 day after PPI administration. Thirty subjects (mean age 42 yr) were enrolled. UBTs were significantly reduced on day 6.5 (p = 0.031); 10 subjects (33%) developed transient negative UBTs. The UBT recovered in all but one subject by the fourth day post-PPI and in all subjects by day 14. In the culture and histology experiment, upon PPI rechallenge, three of nine subjects (33%) had negative UBTs. H. pylori density, whether measured by culture or histology, decreased with PPI therapy; antral biopsies became histologically negative in five subjects and corpus biopsies in three subjects. PPI-induced negative UBT results were related to the anti-H. pylori effect of the PPI. Acidification of the stomach did not prevent false negative UBT results. Three days is likely the minimum delay from stopping PPI until one should perform a test for active infection. A delay of 14 days is preferred.
Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?
Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M. Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz
2015-01-01
Background Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Methodology/Principal Findings Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). Conclusion The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study. PMID:26161864
Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?
Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz
2015-01-01
Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.
[Analysis for Discordance of Positive and Negative Blood Typing by Gel Card].
Li, Cui-Ying; Xu, Hong; Lei, Hui-Fen; Liu, Juan; Li, Xiao-Wei
2017-08-01
To explore the method of Gel card identifying ABO blood group, determine the inconsistent cause and the distribution of disease affecting factors, and put forward a method of its solutions. To collect 240 positive and negative typing-discordant blood speciments from patients examined by Gel card and send these speciments to blood type reference laboratory for examining with the classic tube method and serological test, such as salivary blood-group substance, in order to performe genotyping method when serologic test can not be determined. Among 240 positive and negative typing-discordant blood speciments from patients examined by Gel card, 107 blood speciments were positive and negative consistent examined by false agglutination test (44.58%), 133 blood specinents were discordent examined by false agglutination (55.42%), out of them, 35 cases (14.58%) with inconsistent cold agglutination test, 22 cases (9.17%) with weakened AB antigenicity, 16 cases (6.67%) with ABO subtyping, 12 cases (5.00%) with positive direct antiglobulin test, 11 cases (4.58%) with reduced or without antibodies, 11 cases (4.58%) with false aggregation caused by drugs or protein, 11 cases (4.58%) with salivary blood-type substances, 8 cases (3.33%) with non-ABO alloantibody, and 7 cases (2.92%) with allogeneic bone marrow transplantation. The distribution of disease were following: blood disease (16.83%), tumor (11.88%), and cardiopulmonary diseases (11.39%); chi-square test results indicated that the distribution significantly different. The analysis of ABO blood grouping shows a variety factors influencing positive and negative blood typing, and the Gel Card identification can produc more false positive blood types. Therefore, more attention should be paid on the high incidence diseases, such as blood disease, tumor, and cardiopulmonary disease.
Østergaard, Mia L; Nielsen, Kristina R; Albrecht-Beste, Elisabeth; Konge, Lars; Nielsen, Michael B
2018-01-01
This study aimed to develop a test with validity evidence for abdominal diagnostic ultrasound with a pass/fail-standard to facilitate mastery learning. The simulator had 150 real-life patient abdominal scans of which 15 cases with 44 findings were selected, representing level 1 from The European Federation of Societies for Ultrasound in Medicine and Biology. Four groups of experience levels were constructed: Novices (medical students), trainees (first-year radiology residents), intermediates (third- to fourth-year radiology residents) and advanced (physicians with ultrasound fellowship). Participants were tested in a standardized setup and scored by two blinded reviewers prior to an item analysis. The item analysis excluded 14 diagnoses. Both internal consistency (Cronbach's alpha 0.96) and inter-rater reliability (0.99) were good and there were statistically significant differences (p < 0.001) between all four groups, except the intermediate and advanced groups (p = 1.0). There was a statistically significant correlation between experience and test scores (Pearson's r = 0.82, p < 0.001). The pass/fail-standard failed all novices (no false positives) and passed all advanced (no false negatives). All intermediate participants and six out of 14 trainees passed. We developed a test for diagnostic abdominal ultrasound with solid validity evidence and a pass/fail-standard without any false-positive or false-negative scores. • Ultrasound training can benefit from competency-based education based on reliable tests. • This simulation-based test can differentiate between competency levels of ultrasound examiners. • This test is suitable for competency-based education, e.g. mastery learning. • We provide a pass/fail standard without false-negative or false-positive scores.
Underpowered samples, false negatives, and unconscious learning.
Vadillo, Miguel A; Konstantinidis, Emmanouil; Shanks, David R
2016-02-01
The scientific community has witnessed growing concern about the high rate of false positives and unreliable results within the psychological literature, but the harmful impact of false negatives has been largely ignored. False negatives are particularly concerning in research areas where demonstrating the absence of an effect is crucial, such as studies of unconscious or implicit processing. Research on implicit processes seeks evidence of above-chance performance on some implicit behavioral measure at the same time as chance-level performance (that is, a null result) on an explicit measure of awareness. A systematic review of 73 studies of contextual cuing, a popular implicit learning paradigm, involving 181 statistical analyses of awareness tests, reveals how underpowered studies can lead to failure to reject a false null hypothesis. Among the studies that reported sufficient information, the meta-analytic effect size across awareness tests was d z = 0.31 (95 % CI 0.24-0.37), showing that participants' learning in these experiments was conscious. The unusually large number of positive results in this literature cannot be explained by selective publication. Instead, our analyses demonstrate that these tests are typically insensitive and underpowered to detect medium to small, but true, effects in awareness tests. These findings challenge a widespread and theoretically important claim about the extent of unconscious human cognition.
Performance of acidified 14C-urea capsule breath test during pantoprazole and ranitidine treatment.
Oztürk, Emel; Yeşilova, Zeki; Ilgan, Seyfettin; Ozgüven, Mehmet; Dağalp, Kemal
2009-07-01
Urea breath test (UBT) results could be false negative in patients taking antisecretory drugs. This effect would be prevented by citric acid administration during UBT. We prospectively investigated whether acidified 14C-urea capsule prevents false negative UBT results in patients taking antisecretory drugs and show interference with the duration of medications. Sixty Helicobacter pylori positive patients were included. Pantoprazole (40 mg/day) was given to 27 patients for 28 days and ranitidine (300 mg. o.d.) to 33 patients for 60 days. Urea breath tests were repeated on days 14 and 28 in both groups and on day 60 in the ranitidine group. The baseline mean breath counts of two groups did not show any significant difference. Pantoprazole led to a significant decrease in mean breath counts on day 14 (P < 0.005). Six of 27 and 3 of 25 patients taking pantoprazole developed negative or equivocal UBT results on days 14 and 28, respectively. Two of 32, 2 of 32 and 3 of 21 patients taking ranitidine developed negative or equivocal UBT results on days 14, 28 and 60, respectively. The use of acidified 14C-urea capsule did not prevent false negative UBT results in patients taking pantoprazole and ranitidine, and the duration of medication does not affect the test results.
Emotions and false memories: valence or arousal?
Corson, Yves; Verrier, Nadège
2007-03-01
The effects of mood on false memories have not been studied systematically until recently. Some results seem to indicate that negative mood may reduce false recall and thus suggest an influence of emotional valence on false memory. The present research tested the effects of both valence and arousal on recall and recognition and indicates that the effect is actually due to arousal. In fact, whether participants' mood is positive, negative, or neutral, false memories are significantly more frequent under conditions of high arousal than under conditions of low arousal.
Ramirez-Arcos, Sandra; DiFranco, Caesar; McIntyre, Terri; Goldman, Mindy
2017-09-01
Canadian Blood Services screens 100% of platelet concentrates (PCs) for bacterial contamination with the BacT/ALERT system. Quality-control sterility testing of 1% (≥10 units) of outdated PCs is performed monthly. Data from routine screening, quality-control testing, and septic reactions obtained from 2010 to 2016 are presented herein. In total, 601,988 buffy coat PC pools and 186,737 apheresis PCs were routinely screened with aerobic cultures over 6 years. Outdate quality-control testing of 8535 buffy coat and 8498 apheresis PCs was performed using aerobic and anaerobic cultures during the same period. Results were classified as "true-positives" when the same bacterium was isolated in initial and confirmatory cultures or "false-negatives" when bacteria were missed in early screening and were captured during quality-control sterility testing or through investigation of sepsis cases. During routine screening, the true-positive rates between buffy coat (0.94 per 10,000) and apheresis (0.96 per 10,000) PCs were similar (p = 0.9473). Seventy-five bacteria isolated during PC screening included Gram-positive and Gram-negative organisms. Six false-negative septic reactions were reported that implicated coagulase-negative staphylococci (n = 3) and Staphylococcus aureus (n = 3) for approximate rates of 1 per 100,000 transfusion reactions and 1 per 500,000 fatalities. During quality-control testing, the false-negative rates between buffy coat (8 per 10,000) and apheresis (9 per 10,000) PCs were similar (p = 0.7897). All 15 quality-control isolates were Gram-positive bacteria. The current bacterial screening protocol is efficacious for identifying Gram-negative bacteria. However, the high proportion of Gram-positive organisms detected on outdate quality-control testing and septic transfusion events demonstrates a residual safety risk that merits further intervention. © 2017 AABB.
Ndase, Patrick; Celum, Connie; Kidoguchi, Lara; Ronald, Allan; Fife, Kenneth H; Bukusi, Elizabeth; Donnell, Deborah; Baeten, Jared M
2015-01-01
Rapid HIV assays are the mainstay of HIV testing globally. Delivery of effective biomedical HIV prevention strategies such as antiretroviral pre-exposure prophylaxis (PrEP) requires periodic HIV testing. Because rapid tests have high (>95%) but imperfect specificity, they are expected to generate some false positive results. We assessed the frequency of true and false positive rapid results in the Partners PrEP Study, a randomized, placebo-controlled trial of PrEP. HIV testing was performed monthly using 2 rapid tests done in parallel with HIV enzyme immunoassay (EIA) confirmation following all positive rapid tests. A total of 99,009 monthly HIV tests were performed; 98,743 (99.7%) were dual-rapid HIV negative. Of the 266 visits with ≥1 positive rapid result, 99 (37.2%) had confirmatory positive EIA results (true positives), 155 (58.3%) had negative EIA results (false positives), and 12 (4.5%) had discordant EIA results. In the active PrEP arms, over two-thirds of visits with positive rapid test results were false positive results (69.2%, 110 of 159), although false positive results occurred at <1% (110/65,945) of total visits. When HIV prevalence or incidence is low due to effective HIV prevention interventions, rapid HIV tests result in a high number of false relative to true positive results, although the absolute number of false results will be low. Program roll-out for effective interventions should plan for quality assurance of HIV testing, mechanisms for confirmatory HIV testing, and counseling strategies for persons with positive rapid test results.
Application of Immunosignatures for Diagnosis of Valley Fever
Navalkar, Krupa Arun; Johnston, Stephen Albert; Woodbury, Neal; Galgiani, John N.; Magee, D. Mitchell; Chicacz, Zbigniew
2014-01-01
Valley fever (VF) is difficult to diagnose, partly because the symptoms of VF are confounded with those of other community-acquired pneumonias. Confirmatory diagnostics detect IgM and IgG antibodies against coccidioidal antigens via immunodiffusion (ID). The false-negative rate can be as high as 50% to 70%, with 5% of symptomatic patients never showing detectable antibody levels. In this study, we tested whether the immunosignature diagnostic can resolve VF false negatives. An immunosignature is the pattern of antibody binding to random-sequence peptides on a peptide microarray. A 10,000-peptide microarray was first used to determine whether valley fever patients can be distinguished from 3 other cohorts with similar infections. After determining the VF-specific peptides, a small 96-peptide diagnostic array was created and tested. The performances of the 10,000-peptide array and the 96-peptide diagnostic array were compared to that of the ID diagnostic standard. The 10,000-peptide microarray classified the VF samples from the other 3 infections with 98% accuracy. It also classified VF false-negative patients with 100% sensitivity in a blinded test set versus 28% sensitivity for ID. The immunosignature microarray has potential for simultaneously distinguishing valley fever patients from those with other fungal or bacterial infections. The same 10,000-peptide array can diagnose VF false-negative patients with 100% sensitivity. The smaller 96-peptide diagnostic array was less specific for diagnosing false negatives. We conclude that the performance of the immunosignature diagnostic exceeds that of the existing standard, and the immunosignature can distinguish related infections and might be used in lieu of existing diagnostics. PMID:24964807
Role of Urine Drug Testing in the Current Opioid Epidemic.
Mahajan, Gagan
2017-12-01
While the evidence for urine drug testing for patients on chronic opioid therapy is weak, the guidelines created by numerous medical societies and state and federal regulatory agencies recommend that it be included as one of the tools used to monitor patients for compliance with chronic opioid therapy. To get the most comprehensive results, clinicians should order both an immunoassay screen and confirmatory urine drug test. The immunoassay screen, which can be performed as an in-office point-of-care test or as a laboratory-based test, is a cheap and convenient study to order. Limitations of an immunoassay screen, however, include having a high threshold of detectability and only providing qualitative information about a select number of drug classes. Because of these restrictions, clinicians should understand that immunoassay screens have high false-positive and false-negative rates. Despite these limitations, though, the results can assist the clinician with making preliminary treatment decisions. In comparison, a confirmatory urine drug test, which can only be performed as a laboratory-based test, has a lower threshold of detectability and provides both qualitative and quantitative information. A urine drug test's greater degree of specificity allows for a relatively low false-negative and false-positive rate in contrast to an immunoassay screen. Like any other diagnostic test, an immunoassay screen and a confirmatory urine drug test both possess limitations. Clinicians must keep this in mind when interpreting an unexpected test result and consult with their laboratory when in doubt about the meaning of the test result to avoid making erroneous decisions that negatively impact both the patient and clinician.
Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck
2015-05-14
Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false negative results due to seroconversion or misclassification by the lower sensitivity dilution test. Further research is needed to determine if these results can be replicated in other settings. ClinicalTrials.gov, NCT01716299 .
Screening for acute HIV infection in South Africa: finding acute and chronic disease
Bassett, Ingrid V.; Chetty, Senica; Giddy, Janet; Reddy, Shabashini; Bishop, Karen; Lu, Zhigang; Losina, Elena; Freedberg, Kenneth A.; Walensky, Rochelle P.
2010-01-01
Background The yield of screening for acute HIV infection among general medical patients in resource-scarce settings remains unclear. Our objective was to evaluate a strategy of pooled HIV plasma RNA to diagnose acute HIV infection in patients with negative or discordant rapid HIV antibody tests in Durban, South Africa. Methods We prospectively enrolled patients with negative or discordant rapid HIV antibody tests from a routine HIV screening program in an outpatient department in Durban with an HIV prevalence of 48%. Study participants underwent venipuncture for pooled qualitative HIV RNA, and if positive, quantitative RNA, enzyme immunoassay and Western Blot (WB). Patients with negative or indeterminate WB and positive quantitative HIV RNA were considered acutely infected. Those with chronic infection (positive RNA and WB) despite negative or discordant rapid HIV tests were considered false negative rapid antibody tests. Results Nine hundred ninety-four participants were enrolled with either negative (N=976) or discordant (N=18) rapid test results. Eleven (1.1%, 95% CI: 0.6–2.0%) had acute HIV infection. Of the 994 patients, an additional 20 (2.0%, 95% CI: 1.3–.3.1%) had chronic HIV infection (false negative rapid test). Conclusions One percent of outpatients with negative or discordant rapid HIV tests in Durban, South Africa had acute HIV infection readily detectable through pooled serum HIV RNA screening. Pooled RNA testing also identified an additional 2% of patients with chronic HIV infection. HIV RNA screening has the potential to identify both acute and chronic HIV infections that are otherwise missed by standard HIV testing algorithms. PMID:20553336
Edwards, Jeffrey K; Kleine, Christian; Munster, Vincent; Giuliani, Ruggero; Massaquoi, Moses; Sprecher, Armand; Chertow, Daniel S
2015-12-01
Quantitative reverse-transcription polymerase chain reaction (qRT-PCR) is the most sensitive quantitative diagnostic assay for detection of Ebola virus in multiple body fluids. Despite the strengths of this assay, we present 2 cases of Ebola virus disease (EVD) and highlight the potential for false-negative results during the early and late stages of EVD. The first case emphasizes the low negative-predictive value of qRT-PCR during incubation and the early febrile stage of EVD, and the second case emphasizes the potential for false-negative results during recovery and late neurologic complications of EVD. Careful interpretation of test results are needed to guide difficult admission and discharge decisions in suspected or confirmed EVD.
Bonanzinga, Tommaso; Zahar, Akos; Dütsch, Michael; Lausmann, Christian; Kendoff, Daniel; Gehrke, Thorsten
2017-02-01
A key issue in the treatment of periprosthetic joint infection (PJI) is the correct diagnosis. The main problem is lack of diagnostic tools able to diagnose a PJI with high accuracy. Alpha-defensin has been proposed as a possible solution, but in the current literature, there is a lack of independent validation. We performed a prospective study to determine (1) what is the sensitivity, specificity, and positive and the negative predictive values of the alpha-defensin immunoassay test in diagnosing PJI; and (2) which clinical features may be responsible for false-positive and false-negative results? Preoperative aspiration was performed in all patients presenting with a painful hip/knee arthroplasty, including both primary and revision implants. Metallosis, other inflammatory comorbidities, and previous/concomitant antibiotic therapy were not considered as exclusion criteria. An inadequate amount of synovial fluid for culture was an exclusion criterion. A total of 156 patients (65 knees, 91 hips) were included in this prospective study. At the time of revision, synovial fluid samples were taken to perform the alpha-defensin assay. During surgical débridement of tissue, samples for cultures and histologic evaluation were taken, and samples were cultured until positive or until negative at 14 days. A diagnosis of PJI was confirmed in 29 patients according to the International Consensus Group on PJI. The sensitivity of the alpha-defensin immunoassay was 97% (95% confidence interval [CI], 92%-99%), the specificity was 97% (95% CI, 92%-99%), the positive predictive value was 88% (95% CI, 81%-92%), and the negative predictive value was 99% (95% CI, 96%-99%). Among four false-positive patients, two had metallosis and one had polyethylene wear. The false-negative case presented with a draining sinus, and intraoperative cultures were also negative. Alpha-defensin assay appears to be a reliable test, but followup evaluation is needed to estimate longer term performance of the test. The authors believe that alpha-defensin has demonstrated itself to be sufficiently robust that PJI diagnostic criteria now should include this test. Future studies are needed to compare the differences among the diagnostic capability of the available tests, in particular when metallosis is present, because metallosis may predispose the test to a false-positive result. Level I, diagnostic study.
Kim, Sue Jung; Kim, Yoonjung; Shin, Saeam; Song, Jaewoo; Choi, Jong Rak
2012-11-01
In the clinical laboratory, it is important both to reduce the number of peripheral blood slide reviews to save time and money and to avoid reporting false results. To determine differences in the slide review rates of 3 widely used automated hematologic analyzers, the Unicel DxH 800 (Beckman Coulter Inc, Fullerton, California), ADVIA 2120i (Siemens Diagnostics, Tarrytown, New York), and XE 2100 (Sysmex, Kobe, Japan), using International Consensus Group for Hematology Review guidelines. A total of 1485 samples were tested, and 300 were manually reviewed. Slide review rates, sensitivity, specificity, and false-positive and false-negative rates were estimated using consensus group rules and compared using χ(2) tests, Fisher exact tests, or generalized estimating equations. Unicel DxH 800, ADVIA 2120i, and XE 2100 showed 22.8%, 20.2%, and 28.6% slide review rates; 14.3%, 14.3%, and 9.7% false-negative rates; and 13.7, 11.3%, and 17.3% false-positive rates, respectively. All analyzers showed significantly higher false-negative rates than that of the consensus group (2.9%). False-negative rates were higher than the recommended levels. Among 3 automated hematologic analyzers, XE 2100 showed the highest rate of slide review. Because the present study clearly shows that the slide review rates have distinct characteristics among the studied analyzers, each individual laboratory should consider selecting the most appropriate analyzer according to clinical characteristics. Analyzers with high sensitivity may be advantageous in outpatient settings for screening patients, whereas analyzers with high specificity may be beneficial in inpatient settings for efficient patient care.
Kumar, Navin; Pande, Veena; Bhatt, R M; Shah, Naman K; Mishra, Neelima; Srivastava, Bina; Valecha, Neena; Anvikar, Anupkumar R
2013-01-01
Genetic polymorphisms in diagnostic antigens are important factors responsible for variable performance of rapid diagnostic tests. Additionally, the failure of antigen expression due to gene deletion may also contribute to variable performance. We report Indian Plasmodium falciparum field isolates lacking both Pfhrp2 and Pfhrp3 genes leading to false negative results of rapid diagnostic tests. The study highlights need to determine the prevalence of P. falciparum isolates lacking these genes in larger field populations in India. Copyright © 2012 Elsevier B.V. All rights reserved.
Rapid automated method for screening of enteric pathogens from stool specimens.
Villasante, P A; Agulla, A; Merino, F J; Pérez, T; Ladrón de Guevara, C; Velasco, A C
1987-01-01
A total of 800 colonies suggestive of Salmonella, Shigella, or Yersinia species isolated on stool differential agar media were inoculated onto both conventional biochemical test media (triple sugar iron agar, urea agar, and phenylalanine agar) and Entero Pathogen Screen cards of the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). Based on the conventional tests, the AutoMicrobic system method yielded the following results: 587 true-negatives, 185 true-positives, 2 false-negatives, and 26 false-positives (sensitivity, 99%; specificity, 96%). Both true-positive and true-negative results were achieved considerably earlier than false results (P less than 0.001). The Entero Pathogen Screen card method is a fast, easy, and sensitive method for screening for Salmonella, Shigella, or Yersinia species. The impossibility of screening for oxidase-positive pathogens is a minor disadvantage of this method. PMID:3553230
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piepel, Gregory F.; Hutchison, Janine R.
2014-04-16
This report describes the experimental design for a laboratory study to quantify the recovery efficiencies and false negative rates of a validated, macrofoam swab sampling method for low concentrations of Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus (BG) spores on four surface materials (stainless steel, glass, vinyl tile, plastic light cover panel). Two analytical methods (plating/counting and polymerase chain reaction) will be used. Only one previous study has investigated false negative as a function of affecting test factors. The surrogates BAS and BG have not been tested together in the same study previously. Hence, this study will provide for completingmore » gaps in the available information on the performance of macrofoam swab sampling at low concentrations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piepel, Gregory F.; Hutchison, Janine R.
This report describes the experimental design for a laboratory study to quantify the recovery efficiencies and false negative rates of a validated, macrofoam-swab sampling method for low concentrations of Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus (BG) spores on four surface materials (stainless steel, glass, vinyl tile, plastic light cover panel). Two analytical methods (culture and polymerase chain reaction) will be used. Only one previous study has investigated how the false negative rate depends on test factors. The surrogates BAS and BG have not been tested together in the same study previously. Hence, this study will provide for completing gapsmore » in the available information on the performance of macrofoam-swab sampling at low concentrations.« less
Agréus, Lars; Talley, Nicholas J; Jones, Michael
2016-06-01
In populations with a low prevalence rate of Helicobacter pylori (H. pylori) infection from Western countries, guidelines for the management of uninvestigated dyspepsia generally recommend that the "test and treat" strategy should be avoided in favor of empiric proton-pump inhibitor therapy in younger patients (on average < 50 years of age) without alarm symptoms and signs. The prevalence of H. pylori infection has fallen from about 30% to about 10% in Sweden and other countries. We aimed to explore whether the rationale for test and treat is relevant in contemporary clinical practice. In settings with an infection rate in the adult population of 30% and 10%, we modeled the positive and negative predictive values for indirect (nonendoscopy) tests on current H. pylori infection with a presumed sensitivity and specificity of 95%. We then calculated the difference in false-negative and false-positive test outcome, and eradication prescription rates in the two scenarios. While the positive predictive value for the test decreased from 0.89 to 0.68 when the prevalence of H. pylori fell from 30% to 10%, there were only 1% more false-negative tests and 1% less false-positive tests. The eradication prescription rate would decrease by 18% with a 10% prevalence rate. The recommendation to stop applying "test and treat" at lower prevalence rates of H. pylori should be reconsidered. The test and treat strategy is the preferred approach for most patients who present with dyspepsia. © 2015 John Wiley & Sons Ltd.
Galkin, O Yu; Besarab, A B; Lutsenko, T N
2017-01-01
The goal of this work was to study sensitivity and specificity of the developed ELISA set for the identification of IgG antibodies against Chlamydia trachomatis HSP-60 (using biotinylated tyramine-based signal amplification system). The study was conducted using a panel of characterized sera, as well as two reference ELISA sets of similar purpose. According to the results of ELISA informative value parameters, the ELISA we have developed showed the highest specificity and sensitivity parameters (no false negative or false positive results were registered). In 4 out of 15 intralaboratory panel serum samples initially identified as negative, anti-HSP-60 IgG-antibodies test result in reference ELISA sets upon dilution changed from negative to positive. The nature of titration curves of false negative sera and commercial monoclonal antibodies А57-В9 against C. trachomatis HSP-60 after incubation for 24 h was indicative of the presence of anti-idiotypic antibodies in these samples. Upon sera dilution, idiotypic-anti-idiotypic complexes dissociated, which caused the change of test result. High informative value of the developed ELISA set for identification of IgG antibodies against C. trachomatis HSP-60 has been proven. Anti-idiotypic antibodies possessing C. trachomatis anti-HSP-60 activity and being one of the causes of false negative results of the relevant ELISA-based tests have been identified in blood sera of individuals infected with chlamydial genitourinary infection agents.
False feedback and beliefs influence name recall in younger and older adults.
Strickland-Hughes, Carla M; West, Robin Lea; Smith, Kimberly A; Ebner, Natalie C
2017-09-01
Feedback is an important self-regulatory process that affects task effort and subsequent performance. Benefits of positive feedback for list recall have been explored in research on goals and feedback, but the effect of negative feedback on memory has rarely been studied. The current research extends knowledge of memory and feedback effects by investigating face-name association memory and by examining the potential mediation of feedback effects, in younger and older adults, through self-evaluative beliefs. Beliefs were assessed before and after name recognition and name recall testing. Repeated presentation of false positive feedback was compared to false negative feedback and a no feedback condition. Results showed that memory self-efficacy declined over time for participants in the negative and no feedback conditions but was sustained for those receiving positive feedback. Furthermore, participants who received negative feedback felt older after testing than before testing. For name recall, the positive feedback group outperformed the negative feedback and no feedback groups combined, with no age interactions. The observed feedback-related effects on memory were fully mediated by changes in memory self-efficacy. These findings advance our understanding of how beliefs are related to feedback in memory and inform future studies examining the importance of self-regulation in memory.
Wiwanitkit, Viroj; Udomsantisuk, Nibhond; Boonchalermvichian, Chaiyaporn
2005-06-01
The aim of this study was to evaluate the diagnostic properties of urine Gram stain and urine microscopic examination for screening for urinary tract infection (UTI), and to perform an additional cost utility analysis. This descriptive study was performed on 95 urine samples sent for urine culture to the Department of Microbiology, Faculty of Medicine, Chulalongkorn University. The first part of the study was to determine the diagnostic properties of two screening tests (urine Gram stain and urine microscopic examination). Urine culture was set as the gold standard and the results from both methods were compared to this. The second part of this study was to perform a cost utility analysis. The sensitivity of urine Gram stain was 96.2%, the specificity 93.0%, the positive predictive value 94.3% and the negative predictive value 95.2%. False positives occurred with a frequency of 7.0% and false negatives 3.8%. For the microscopic examination, the sensitivity was 65.4%, specificity 74.4%, positive predictive value 75.6% and negative predictive value 64.0%. False positives occurred with a frequency of 25.6% and false negatives 34.6%. Combining urine Gram stain and urine microscopic examination, the sensitivity was 98.1%, specificity 74.4%, positive predictive value 82.3% and negative predictive value 97.0%. False positives occurred with a frequency of 25.6% and false negatives 1.9%. However, the cost per utility of the combined method was higher than either urine microscopic examination or urine Gram stain alone. Urine Gram stain provided the lowest cost per utility. Economically, urine Gram stain is the proper screening tool for presumptive diagnosis of UTI.
Gerstl, Sibylle; Dunkley, Sophie; Mukhtar, Ahmed; De Smet, Martin; Baker, Samuel; Maikere, Jacob
2010-01-21
Most malaria rapid diagnostic tests (RDTs) use HRP2 detection, including Paracheck-Pf(R), but their utility is limited by persistent false positivity after treatment. PLDH-based tests become negative more quickly, but sensitivity has been reported below the recommended standard of 90%. A new pLDH test, CareStart three-line P.f/PAN-pLDH, claims better sensitivity with continued rapid conversion to negative. The study aims were to 1) compare sensitivity and specificity of CareStart to Paracheck-Pf(R) to diagnose falciparum malaria in children under five years of age, 2) assess how quickly false-positive CareStart tests become negative and 3) evaluate ease of use and inter-reader agreement of both tests. Participants were included if they were aged between two and 59 months, presenting to a Médecins Sans Frontières community health centre in eastern Sierra Leone with suspected malaria defined as fever (axillary temperature > 37.5 degrees C) and/or history of fever in the previous 72 hours and no signs of severe disease. The same capillary blood was used for the RDTs and the blood slide, the latter used as the gold standard reference. All positive participants were treated with supervised artesunate and amodiaquine treatment for three days. Participants with a persistent false-positive CareStart, but a negative blood slide on Day 2, were followed with repeated CareStart and blood slide tests every seven days until CareStart became negative or a maximum of 28 days. Sensitivity of CareStart was 99.4% (CI 96.8-100.0, 168/169) and of Paracheck-Pf(R), 98.8% (95% CI 95.8-99.8, 167/169). Specificity of CareStart was 96.0% (CI 91.9-98.4, 167/174) and of Paracheck-Pf(R), 74.7% (CI 67.6-81.0, 130/174) (p < 0.001). Neither test showed any change in sensitivity with decreasing parasitaemia. Of the 155 eligible follow-up CareStart participants, 63.9% (99/155) had a false-positive test on day 2, 21.3% (33/155) on day 7, 5.8% (9/155) on day 14, 1.9% (3/155) on day 21 and 0.6% (1/155) on day 28. The median time for test negativity was seven days. CareStart was as easy to use and interpret as Paracheck-Pf(R) with excellent inter-reader agreement. Both RDTs were highly sensitive, met WHO standards for the detection of falciparum malaria monoinfections where parasitaemia was >100 parasites/mul and were easy to use. CareStart persistent false positivity decreased quickly after successful anti-malarial treatment, making it a good choice for a RDT for a hyperendemic falciparum malaria area.
Dehon, Hedwige; Larøi, Frank; Van der Linden, Martial
2010-10-01
This study examined the influence of emotional valence on the production of DRM false memories (Roediger & McDermott, 1995). Participants were presented with neutral, positive, or negative DRM lists for a later recognition (Experiment 1) or recall (Experiment 2) test. In both experiments, confidence and recollective experience (i.e., "Remember-Know" judgments; Tulving, 1985) were also assessed. Results consistently showed that, compared with neutral lists, affective lists induced more false recognition and recall of nonpresented critical lures. Moreover, although confidence ratings did not differ between the false remembering from the different kinds of lists, "Remember" responses were more often associated with negative than positive and neutral false remembering of the critical lures. In contrast, positive false remembering of the critical lures was more often associated with "Know" responses. These results are discussed in light of the Paradoxical Negative Emotion (PNE) hypothesis (Porter, Taylor, & ten Bricke, 2008). (PsycINFO Database Record (c) 2010 APA, all rights reserved).
False-positive cryptococcal antigen latex agglutination caused by disinfectants and soaps.
Blevins, L B; Fenn, J; Segal, H; Newcomb-Gayman, P; Carroll, K C
1995-01-01
Five disinfectants or soaps were tested to determine if any could be responsible for false-positive results obtained with the Latex-Crypto Antigen Detection System kit (Immuno-Mycologics, Inc., Norman, Okla.). Three disinfectants or soaps (Derma soap, 7X, and Bacdown) produced false-positive agglutination after repeated washing of ring slides during testing of a known negative cerebrospinal fluid specimen. PMID:7650214
Mundangepfupfu, Tichaendepi; Waseem, Muhammad
2014-03-01
Hydatidiform mole (molar pregnancy) is a benign tumor of placental trophoblastic cells, which release human chorionic gonadotropin (hCG). Several case reports have described complete hydatidiform moles with false-negative urine qualitative hCG tests. These negative pregnancy tests have been attributed to the hook effect. We report an unusual presentation of a partial mole and review an alternative explanation for the negative hCG test. As partial moles are usually not associated with a large proliferation of trophoblastic cells, levels of hCG are commonly < 100,000 mIU/mL. The most common presentation of a hydatidiform mole is vaginal bleeding. Hydatidiform mole is associated with a risk of malignant transformation and disseminated disease. In a pregnant patient, vaginal bleeding and abdominal pain are common presentations. Molar pregnancy is an uncommon cause of abdominal pain and vaginal bleeding that should be considered. A 47-year-old female presented to the emergency department with abdominal pain and vaginal bleeding. Urine qualitative hCG was negative and serum quantitative hCG was 1,094,950 mIU/mL. Pelvic ultrasonography showed a uterine cavity containing a soft-tissue mass with multiple cystic lesions and the hydatidiform mole was extracted with suction curettage. Tissue pathology confirmed partial hydatidiform mole. In addition to the hook effect, we present another possible explanation for the false-negative test; namely the inability of some assays to detect hCG-degradation products, which may be higher in clinical samples from patients with hydatidiform mole. This case underscores the importance of knowing the limitations of the commonly used hCG assays. Copyright © 2014 Elsevier Inc. All rights reserved.
Implications of false-positive results for future cancer screenings.
Taksler, Glen B; Keating, Nancy L; Rothberg, Michael B
2018-06-01
False-positive cancer screening results may affect a patient's willingness to obtain future screening. The authors conducted logistic regression analysis of 450,484 person-years of electronic medical records (2006-2015) in 92,405 individuals aged 50 to 75 years. Exposures were false-positive breast, prostate, or colorectal cancer screening test results (repeat breast imaging or negative breast biopsy ≤3 months after screening mammography, repeat prostate-specific antigen [PSA] test ≤3 months after PSA test result ≥4.0 ng/mL or negative prostate biopsy ≤3 months after any PSA result, or negative colonoscopy [without biopsy/polypectomy] ≤6 months after a positive fecal occult blood test). Outcomes were up-to-date status with breast or colorectal cancer screening. Covariates included prior screening history, clinical information (eg, family history, obesity, and smoking status), comorbidity, and demographics. Women were more likely to be up to date with breast cancer screening if they previously had false-positive mammography findings (adjusted odds ratio [AOR], 1.43 [95% confidence interval, 1.34-1.51] without breast biopsy and AOR, 2.02 [95% confidence interval, 1.56-2.62] with breast biopsy; both P<.001). The same women were more likely to be up to date with colorectal cancer screening (AOR range, 1.25-1.47 depending on breast biopsy; both P<.001). Men who previously had false-positive PSA testing were more likely to be up to date with colorectal cancer screening (AOR, 1.22 [P = .039] without prostate imaging/biopsy and AOR, 1.60 [P = .028] with imaging/biopsy). Results were stronger for individuals with more false-positive results (all P≤.005). However, women with previous false-positive colorectal cancer fecal occult blood test screening results were found to be less likely to be up to date with breast cancer screening (AOR, 0.73; P<.001). Patients who previously had a false-positive breast or prostate cancer screening test were more likely to engage in future screening. Cancer 2018;124:2390-8. © 2018 American Cancer Society. © 2018 American Cancer Society.
Significance of pregnancy test false negative results due to elevated levels of β-core fragment hCG.
Johnson, Sarah; Eapen, Saji; Smith, Peter; Warren, Graham; Zinaman, Michael
2017-01-01
Very high levels of β-core fragment human chorionic gonadotrophin (βcf-hCG) are reported to potentially cause false negative results in point-of-care (POC)/over-the-counter (OTC) pregnancy tests. To investigate this further, women's daily early morning urine samples, collected prior to conception and during pregnancy, were analysed for intact, free β-, and βcf-hCG. The proportion of βcf-hCG was found to be related to that of hCG produced and in circulation. Therefore, best practice for accuracy testing of POC/OTC pregnancy tests would be to test devices against clinical samples containing high levels of βcf-hCG as well as standards spiked with biologically relevant ratios.
Basketter, David A; Gerberick, G Frank; Kimber, Ian
2007-01-01
The local lymph node assay (LLNA) is being used increasingly in the identification of skin sensitizing chemicals for regulatory purposes. In the context of new chemicals legislation (REACH) in Europe, it is the preferred assay. The rationale for this is that the LLNA quantitative and objective approach to skin sensitization testing allied with the important animal welfare benefits that the method offers. However, as with certain guinea pig sensitization tests before it, this increasing use also brings experience with an increasingly wide range of industrial and other chemicals where the outcome of the assay does not always necessarily meet with the expectations of those conducting it. Sometimes, the result appears to be a false negative, but rather more commonly, the complaint is that the chemical represents a false positive. Against this background we have here reviewed a number of instances where false positive and false negative results have been described and have sought to reconcile science with expectation. Based on these analyses, it is our conclusion that false positives and false negatives do occur in the LLNA, as they do with any other skin sensitization assay (and indeed with all tests used for hazard identification), and that this occurs for a number of reasons. We further conclude, however, that false positive results in the LLNA, as with the guinea pig maximization test, arise most commonly via failure to distinguish what is scientifically correct from that which is unpalatable. The consequences of this confusion are discussed in the article, particularly in relation to the need to integrate both potency measurement and risk assessments into classification and labelling schemes that aim to manage potential risks to human health.
True detection limits in an experimental linearly heteroscedastic system.. Part 2
NASA Astrophysics Data System (ADS)
Voigtman, Edward; Abraham, Kevin T.
2011-11-01
Despite much different processing of the experimental fluorescence detection data presented in Part 1, essentially the same estimates were obtained for the true theoretical Currie decision levels ( YC and XC) and true Currie detection limits ( YD and XD). The obtained experimental values, for 5% probability of false positives and 5% probability of false negatives, were YC = 56.0 mV, YD = 125. mV, XC = 0.132 μg/mL and XD = 0.293 μg/mL. For 5% probability of false positives and 1% probability of false negatives, the obtained detection limits were YD = 158 . mV and XD = 0.371 μg/mL. Furthermore, by using bootstrapping methodology on the experimental data for the standards and the analytical blank, it was possible to validate previously published experimental domain expressions for the decision levels ( yC and xC) and detection limits ( yD and xD). This was demonstrated by testing the generated decision levels and detection limits for their performance in regard to false positives and false negatives. In every case, the obtained numbers of false negatives and false positives were as specified a priori.
Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho
2014-01-01
Background: This study was conducted to evaluate the diagnostic validity of the 13C-urea breath test (13C-UBT) in the remnant stomach after partial gastrectomy for gastric cancer. Methods: The 13C-UBT results after Helicobacter pylori eradication therapy was compared with the results of endoscopic biopsy-based methods in the patients who have received partial gastrectomy for the gastric cancer. Results: Among the gastrectomized patients who showed the positive 13C-UBT results (≥ 2.5‰, n = 47) and negative 13C-UBT results (< 2.5‰, n = 114) after H. pylori eradication, 26 patients (16.1%) and 4 patients (2.5%) were found to show false positive and false negative results based on biopsy-based methods, respectively. The sensitivity, specificity, false positive rate, and false negative rate for the cut-off value of 2.5‰ were 84.0%, 80.9%, 19.1%, and 16.0%, respectively. The positive and negative predictive values were 44.7% and 96.5%, respectively. In the multivariate analysis, two or more H. pylori eradication therapies (odds ratio = 3.248, 95% confidence interval= 1.088–9.695, P = 0.035) was associated with a false positive result of the 13C-UBT. Conclusions: After partial gastrectomy, a discordant result was shown in the positive 13C-UBT results compared to the endoscopic biopsy methods for confirming the H. pylori status after eradication. Additional endoscopic biopsy-based H. pylori tests would be helpful to avoid unnecessary treatment for H. pylori eradication in these cases. PMID:25574466
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 1 2013-10-01 2013-10-01 false What are the MRO's functions in reviewing laboratory confirmed non-negative drug test results? 40.129 Section 40.129 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Medical Review Officers and the Verification Proces...
49 CFR 40.127 - What are the MRO's functions in reviewing negative test results?
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 1 2013-10-01 2013-10-01 false What are the MRO's functions in reviewing negative test results? 40.127 Section 40.127 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Medical Review Officers and the Verification Process § 40.127 What are the MRO's...
49 CFR 40.149 - May the MRO change a verified drug test result?
Code of Federal Regulations, 2011 CFR
2011-10-01
... identifying (e.g., a paperwork mistake) or testing (e.g., a false positive or negative) the employee's primary... result only in the following situations: (1) When you have reopened a verification that was done without... laboratory notifies you that it mixed up the two test results, and X was really negative and Y was really...
49 CFR 40.149 - May the MRO change a verified drug test result?
Code of Federal Regulations, 2014 CFR
2014-10-01
... identifying (e.g., a paperwork mistake) or testing (e.g., a false positive or negative) the employee's primary... result only in the following situations: (1) When you have reopened a verification that was done without... laboratory notifies you that it mixed up the two test results, and X was really negative and Y was really...
49 CFR 40.149 - May the MRO change a verified drug test result?
Code of Federal Regulations, 2012 CFR
2012-10-01
... identifying (e.g., a paperwork mistake) or testing (e.g., a false positive or negative) the employee's primary... result only in the following situations: (1) When you have reopened a verification that was done without... laboratory notifies you that it mixed up the two test results, and X was really negative and Y was really...
49 CFR 40.149 - May the MRO change a verified drug test result?
Code of Federal Regulations, 2013 CFR
2013-10-01
... identifying (e.g., a paperwork mistake) or testing (e.g., a false positive or negative) the employee's primary... result only in the following situations: (1) When you have reopened a verification that was done without... laboratory notifies you that it mixed up the two test results, and X was really negative and Y was really...
Tafra, Lorraine; Lannin, Donald R.; Swanson, Melvin S.; Van Eyk, Jason J.; Verbanac, Kathryn M.; Chua, Arlene N.; Ng, Peter C.; Edwards, Maxine S.; Halliday, Bradford E.; Henry, C. Alan; Sommers, Linda M.; Carman, Claire M.; Molin, Melinda R.; Yurko, John E.; Perry, Roger R.; Williams, Robert
2001-01-01
Objective To determine the factors associated with false-negative results on sentinel node biopsy and sentinel node localization (identification rate) in patients with breast cancer enrolled in a multicenter trial using a combination technique of isosulfan blue with technetium sulfur colloid (Tc99). Summary Background Data Sentinel node biopsy is a diagnostic test used to detect breast cancer metastases. To test the reliability of this method, a complete lymph node dissection must be performed to determine the false-negative rate. Single-institution series have reported excellent results, although one multicenter trial reported a false-negative rate as high as 29% using radioisotope alone. A multicenter trial was initiated to test combined use of Tc99 and isosulfan blue. Methods Investigators (both private-practice and academic surgeons) were recruited after attending a course on the technique of sentinel node biopsy. No investigator participated in a learning trial before entering patients. Tc99 and isosulfan blue were injected into the peritumoral region. Results Five hundred twenty-nine patients underwent 535 sentinel node biopsy procedures for an overall identification rate in finding a sentinel node of 87% and a false-negative rate of 13%. The identification rate increased and the false-negative rate decreased to 90% and 4.3%, respectively, after investigators had performed more than 30 cases. Univariate analysis of tumor showed the poorest success rate with older patients and inexperienced surgeons. Multivariate analysis identified both age and experience as independent predictors of failure. However, with older patients, inexperienced surgeons, and patients with five or more metastatic axillary nodes, the false-negative rate was consistently greater. Conclusions This multicenter trial, from both private practice and academic institutions, is an excellent indicator of the general utility of sentinel node biopsy. It establishes the factors that play an important role (patient age, surgical experience, tumor location) and those that are irrelevant (prior surgery, tumor size, Tc99 timing). This widens the applicability of the technique and identifies factors that require further investigation. PMID:11141225
False-positive cancer screens and health-related quality of life.
McGovern, Patricia M; Gross, Cynthia R; Krueger, Richard A; Engelhard, Deborah A; Cordes, Jill E; Church, Timothy R
2004-01-01
By design, screening tests are imperfect-unresponsive to some cancers (false negatives) while occasionally raising suspicion of cancer where none exists (false positives). This pilot study describes patients' responses to having a false-positive screening test for cancer, and identifies screening effects on health-related quality of life (HRQoL). The pilot findings suggest issues important for incorporation in future evaluations of the impact of screening for prostate, lung, colon, or ovarian (PLCO) cancers. Seven focus groups were conducted to identify the nature and meaning of all phases of PLCO screening. Minnesota participants in the Prostate, Lung, Colorectal and Ovarian Cancer Screening Trial who had completed screening, with at least 1 false-positive screen, participated (N = 47). Participants' reactions to abnormal screens and diagnostic work-ups were primarily emotional (eg, anxiety and distress), not physical, and ultimately positive for the majority. Health distress and fear of cancer and death were the major negative aspects of HRQoL identified. These concepts are not typically included in generic HRQoL questionnaires like the SF-36, but are highly relevant to PLCO screening. Clinicians were regarded as underestimating the discomfort of follow-up diagnostic testing. However, relief and assurance appeared to eventually outweigh the negative emotions for most participants. Implications for oncology nurses include the need to consider the emotional consequences of screening in association with screen reliability and validity.
Ibañez-Sanz, Gemma; Garcia, Montse; Milà, Núria; Rodríguez-Moranta, Francisco; Binefa, Gemma; Gómez-Matas, Javier; Benito, Llúcia; Padrol, Isabel; Barenys, Mercè; Moreno, Victor
2017-09-01
The aim of this study was to analyse false-negative (FN) results of the faecal immunochemical test (FIT) and its determinants in a colorectal cancer screening programme in Catalonia. We carried out a cross-sectional study among 218 screenees with a negative FIT result who agreed to undergo a colonoscopy. A false-negative result was defined as the detection, at colonoscopy, of intermediate/high-risk polyps or colorectal cancer in a patient with a previous negative FIT (<20 µgHb/g). Multivariate logistic regression models were constructed to identify sociodemographic (sex, age) and screening variables (quantitative faecal haemoglobin, colonoscopy findings) related to FN results. Adjusted odds ratios and their 95% confidence intervals were estimated. There were 15.6% FN FIT results. Faecal haemoglobin was undetected in 45.5% of these results and was below 4 µgHb/g in 94.0% of the individuals with a FN result. About 60% of the lesions were located in the proximal colon, whereas the expected percentage was 30%. Decreasing the positivity threshold of FIT does not increase the detection rate of advanced neoplasia, but may increase the costs and potential adverse effects.
Matsuda, Chikashi; Moriyama, Hidehiko; Taketani, Takeshi; Shibata, Hiroshi; Nagai, Atsushi
2011-01-01
The presence in serum of the Hepatitis B surface antigen (HBsAg), the outer envelope of the hepatitis B virus (HBV), indicates viral infection, used in laboratory tests to confirm this. We report a case of discrepancy among HBsAg test results detected between measurements in a subject with HB infection. Gene analysis demonstrated several S region gene mutations, not detected previously. We tested 12 measurements e.g., EIA, CLIA, CLEIA, F-EIA, MAT, and IC for whether they could detect our subject's HBsAg and found that it was not recognized by a method using only a single monoclonal antibody to detect HBsAg in two detection processes, in contrast to the 11 other measurements, which used two different antibodies. This case shows that amino acid substitution may cause a false negative result for HBsAg. Gene mutations known to occur in HBV, should thus trigger an awareness of the need to keep in mind that false negative results can happen in case such as ours.
Geerts, L; Adriaens, E; Alépée, N; Guest, R; Willoughby, J A; Kandarova, H; Drzewiecka, A; Fochtman, P; Verstraelen, S; Van Rompay, A R
2018-06-01
Assessment of ocular irritation is a regulatory requirement in safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as stand-alone assays. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed to assess the reliability of eight in vitro test methods and computational models as well as establishing an optimal tiered-testing strategy. For three computational models (Toxtree, and Case Ultra EYE_DRAIZE and EYE_IRR) performance parameters were calculated. Coverage ranged from 15 to 58%. Coverage was 2 to 3.4 times higher for liquids than for solids. The lowest number of false positives (5%) was reached with EYE_IRR; this model however also gave a high number of false negatives (46%). The lowest number of false negatives (25%) was seen with Toxtree; for liquids Toxtree predicted the lowest number of false negatives (11%), for solids EYE_DRAIZE did (17%). It can be concluded that the training sets should be enlarged with high quality data. The tested models are not yet sufficiently powerful for stand-alone evaluations, but that they can surely become of value in an integrated weight-of-evidence approach in hazard assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.
Lavoie, S; Caswell, D; Gill, M J; Kadkhoda, K; Charlton, C L; Levett, P N; Hatchette, T; Garceau, R; Maregmen, J; Mazzulli, T; Needle, R; Kadivar, K; Kim, J
2018-07-01
False-reactivity in HIV-negative specimens has been detected in HIV fourth-generation antigen/antibody or 'combo' assays which are able to detect both anti-HIV-1/HIV-2 antibodies and HIV-1 antigen. We sought to characterize these specimens and determine the effect of heterophilic interference. Specimens previously testing as false-reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay and re-tested on a different (Siemens ADVIA Centaur HIV Ag/Ab) assay. A subset of these specimens were also pre-treated with heterophilic blocking agents and re-tested on the Abbott assay. Here we report that 95% (252/264) of clinical specimens that were repeatedly reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay (S/Co range, 0.94-678) were negative when re-tested on a different fourth generation HIV combo assay (Siemens ADVIA Centaur HIV Ag/Ab). All 264 samples were subsequently confirmed to be HIV negative. On a small subset (57) of specimens with available volume, pre-treatment with two different reagents (HBT; Heterophilic Blocking Tube, NABT; Non-Specific Blocking Tube) designed to block heterophilic antibody interference either eliminated (HBT) or reduced (NABT) the false reactivity when re-tested on the ARCHITECT HIV Ag/Ab combo assay. Our results suggest that the Abbott ARCHITECT HIV Ag/Ab combo assay can be prone to heterophilic antibody interference. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.
Lipkus, Isaac M; Samsa, Gregory P; Dement, John; Skinner, Celette Sugg; Green, La Sonya G; Pompeii, Lisa; Ransohoff, David F
2003-11-01
Inaccuracy in self-reports of colorectal cancer (CRC) screening procedures (e.g., over- or underreporting) may interfere with individuals adhering to appropriate screening intervals, and can blur the true effects of physician recommendations to screen and the effects of interventions designed to promote screening. We assessed accuracy of self-report of having a fecal occult blood test (FOBT) within a 1-year window based on receipt of FOBT kits among individuals aged 50 and older in the carpentry trade (N = 658) who were off-schedule for having had a FOBT. Indices of evaluating accuracy of self-reports (concordance, specificity, false-positive and false-negative rates) were calculated relative to receipt of a mailed FOBT. Among those who mailed a completed FOBT, we assessed accuracy of reporting the test result. Participants underestimated having performed a FOBT (false-negative rate of 44%). Accuracy was unrelated to perceptions of getting or worrying about CRC or family history. Self-reports of having a negative FOBT result more consistently matched the laboratory result (specificity 98%) than having a positive test result (sensitivity 63%). Contrary to other findings, participants under- rather than over reported FOBT screening. Results suggest greater efforts are needed to enhance accurate recall of FOBT screening.
Evaluation of the LDBIO point of care test for the combined detection of toxoplasmic IgG and IgM.
Chapey, Emmanuelle; Wallon, Martine; Peyron, François
2017-01-01
The toxoplasma ICT IgG-IgM rapid diagnostic test for the simultaneous detection of specific toxoplasmic immunoglobulin (Ig) G and IgM was compared with the Architect fully automated chemiluminescence test. Four hundred sera were included, among which 248 scored negative in Architect. The cassettes were easily read with the naked eye. Diagnostic sensitivity and specificity were 97% and 96%, respectively. The test scored 8 false-positive IgG and yielded negative results in 3 sera displaying unspecific IgM in Architect. The LDBIO appears to be a reliable first line test, although the false-positive results for IgG deserve further investigation. Such an easily performed test could be used advantageously for screening for toxoplasmosis in pregnant women. Copyright © 2016 Elsevier B.V. All rights reserved.
Lucovnik, Miha; Chambliss, Linda R; Blumrick, Richard; Balducci, James; Gersak, Ksenija; Garfield, Robert E
2016-10-01
It has been shown that noninvasive uterine electromyography (EMG) can identify true preterm labor more accurately than methods available to clinicians today. The objective of this study was to evaluate the effect of body mass index (BMI) on the accuracy of uterine EMG in predicting preterm delivery. Predictive values of uterine EMG for preterm delivery were compared in obese versus overweight/normal BMI patients. Hanley-McNeil test was used to compare receiver operator characteristics curves in these groups. Previously reported EMG cutoffs were used to determine groups with false positive/false negative and true positive/true negative EMG results. BMI in these groups was compared with Student t test (p < 0.05 significant). A total of 88 patients were included: 20 obese, 64 overweight, and four with normal BMI. EMG predicted preterm delivery within 7 days with area under the curve = 0.95 in the normal/overweight group, and with area under the curve = 1.00 in the obese group (p = 0.08). Six patients in true preterm labor (delivering within 7 days from EMG measurement) had low EMG values (false negative group). There were no false positive results. No significant differences in patient's BMI were noted between false negative group patients and preterm labor patients with high EMG values (true positive group) and nonlabor patients with low EMG values (true negative group; p = 0.32). Accuracy of noninvasive uterine EMG monitoring and its predictive value for preterm delivery are not affected by obesity. Copyright © 2016. Published by Elsevier B.V.
Saingam, Prakit; Li, Bo; Yan, Tao
2018-06-01
DNA-based molecular detection of microbial pathogens in complex environments is still plagued by sensitivity, specificity and robustness issues. We propose to address these issues by viewing them as inadvertent consequences of requiring specific and adequate amplification (SAA) of target DNA molecules by current PCR methods. Using the invA gene of Salmonella as the model system, we investigated if next generation sequencing (NGS) can be used to directly detect target sequences in false-negative PCR reaction (PCR-NGS) in order to remove the SAA requirement from PCR. False-negative PCR and qPCR reactions were first created using serial dilutions of laboratory-prepared Salmonella genomic DNA and then analyzed directly by NGS. Target invA sequences were detected in all false-negative PCR and qPCR reactions, which lowered the method detection limits near the theoretical minimum of single gene copy detection. The capability of the PCR-NGS approach in correcting false negativity was further tested and confirmed under more environmentally relevant conditions using Salmonella-spiked stream water and sediment samples. Finally, the PCR-NGS approach was applied to ten urban stream water samples and detected invA sequences in eight samples that would be otherwise deemed Salmonella negative. Analysis of the non-target sequences in the false-negative reactions helped to identify primer dime-like short sequences as the main cause of the false negativity. Together, the results demonstrated that the PCR-NGS approach can significantly improve method sensitivity, correct false-negative detections, and enable sequence-based analysis for failure diagnostics in complex environmental samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Larsen, C P; Ezligini, F; Hermansen, N O; Kjeldsen-Kragh, J
2005-02-01
Approximately 1 in every 2000 units of platelets is contaminated with bacteria. The BacT/ALERT automated blood culture system can be used to screen platelet concentrates (PCs) for bacterial contamination. Data were collected from May 1998 until May 2004. The number of PCs tested during this period was 36 896, most of which were produced from pools of four buffy-coats. On the day following blood collection or platelet apheresis, a 5-10 ml sample of the PC was aseptically transferred to a BacT/ALERT culture bottle for detection of aerobic bacteria. The sample was monitored for bacterial growth during the entire storage period of the PC (6.5 days). When a positive signal was generated, the culture bottle, the PC and the erythrocyte concentrates were tested for bacterial growth. In order to determine the frequency of false-negative BacT/ALERT signals, 1061 outdated PCs were tested during the period from May 2002 to May 2004. Eighty-eight positive signals were detected by the BacT/ALERT system, of which 12 were interpreted as truly positive. Fourteen signals were interpreted as truly false positive. Thirty-three signals were interpreted to be probably false positive. Two of 1061 outdated units tested positive, and Bacillus spp. and Staphylococcus epidermidis, respectively, were isolated from these PCs. Between 0.03% and 0.12% of the PCs were contaminated with bacteria. BacT/ALERT is an efficient tool for monitoring PCs for bacterial contamination; however, it is important to realize that false-negative results may occur.
Rosenfield, Lana; Kalicinsky, Chrystyna; Warrington, Richard
2015-01-01
A history of penicillin allergy in patients is common, but only 10-15 % are truly allergic. While the gold standard for diagnosing penicillin allergy is challenge, it is not recommended that this be done without first carrying out diagnostic skin testing. This is carried out with the major determinant benzylpenicilloyl (PPL) and the minor determinant mixture (MDM), consisting of penilloate, penicilloate and Penicillin G. However, since availability of the MDM is limited, Penicillin G alone has been used. A retrospective chart review was carried out on patients tested for penicillin allergy in the Clinical Immunology and Allergy Clinic at the Health Sciences Centre, Winnipeg, Canada between 2005 and 2013. A total of 521 patients charts were reviewed, of whom 240 had skin testing, ImmunoCap(®) for IgE to Penicillin G and V and had oral challenges with penicillin, amoxicillin or cloxacillin. 17/240 (7.5 %) were skin test positive, 8 to PPL, 4 to MDM and 5 to Penicillin G. One was also positive on ImmunoCap(®) testing. Three patients had negative skin tests but weakly positive ImmunoCap(®). 222 patients with negative skin tests and serological tests were challenged. Of these, 12 patients reacted to challenge. Three of the challenges were equivocal. Of the nine patients with definite positive challenges, three were tested with Penicillin G and six with MDM. Therefore the false negative rates for testing were 2.3 % with PPL and Penicillin G and 6.97 % for PPL and MDM. The difference was not significant (p = 0.0856). In this group of patients with a history of penicillin allergy tested with the major determinant of benzyl penicillin and either MDM or Penicillin G, there was no difference in the rate of false negative testing, based on oral penicillin challenges. Therefore, Penicillin G can be safely used as an alternative to MDM in diagnosing penicillin allergy.
True detection limits in an experimental linearly heteroscedastic system. Part 1
NASA Astrophysics Data System (ADS)
Voigtman, Edward; Abraham, Kevin T.
2011-11-01
Using a lab-constructed laser-excited filter fluorimeter deliberately designed to exhibit linearly heteroscedastic, additive Gaussian noise, it has been shown that accurate estimates may be made of the true theoretical Currie decision levels ( YC and XC) and true Currie detection limits ( YD and XD) for the detection of rhodamine 6 G tetrafluoroborate in ethanol. The obtained experimental values, for 5% probability of false positives and 5% probability of false negatives, were YC = 56.1 mV, YD = 125. mV, XC = 0.132 μg /mL and XD = 0.294 μg /mL. For 5% probability of false positives and 1% probability of false negatives, the obtained detection limits were YD = 158. mV and XD = 0.372 μg /mL. These decision levels and corresponding detection limits were shown to pass the ultimate test: they resulted in observed probabilities of false positives and false negatives that were statistically equivalent to the a priori specified values.
HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites
Kosack, Cara S.; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng’ang’a, Anne; Andre, Bita; Zahinda, Jean-Paul BN; Fransen, Katrien; Page, Anne-Laure
2017-01-01
Abstract Introduction: We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. Methods: In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Results: Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. Conclusions: The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy. PMID:28691437
HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites.
Kosack, Cara S; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng'ang'a, Anne; Andre, Bita; Zahinda, Jean-Paul Bn; Fransen, Katrien; Page, Anne-Laure
2017-07-03
We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy.
Lower Cutoffs for LC-MS/MS Urine Drug Testing Indicates Better Patient Compliance.
Krock, Kevin; Pesce, Amadeo; Ritz, Dennis; Thomas, Richard; Cua, Agnes; Rogers, Ryan; Lipnick, Phil; Kilbourn, Kristen
2017-11-01
Urine drug testing is used by health care providers to determine a patient's compliance to their prescribed regimen and to detect non-prescribed medications and illicit drugs. However, the cutoff levels used by clinical labs are often arbitrarily set and may not reflect the urine drug concentrations of compliant patients. Our aim was to test the hypothesis that commonly used cutoffs for many prescribed and illicit drugs were set too high, and methods using these cutoffs may yield a considerable number of false-negative results. The goals of this study were to outline the way to analyze patient results and estimate a more appropriate cutoff, develop and validate a high sensitivity analytical method capable of quantitating drugs and metabolites at lower than the commonly used cutoffs, and determine the number of true positive results that would have been missed when using the common cutoffs. This was a retrospective study of urine specimens submitted for urine drug testing as part of the monitoring of prescription drug compliance described in chronic opioid therapy treatment guidelines. The study was set in a clinical toxicology laboratory, using specimens submitted for routine analysis by health care providers in the normal course of business. Lognormal distributions of test results were generated and fitted with a trendline to estimate the required cutoff level necessary to capture the normal distributions of each drug for the patient population study. A validated laboratory derived liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis capable of achieving the required cutoff levels was developed for each drug and/or metabolite. The study shows that a lognormal distribution of patient urine test results fitted with a trendline is appropriate for estimating the required cutoff levels needed to assess medication adherence. The study showed a wide variation in the false-negative rate, ranging from 1.5% to 94.3% across a range of prescribed and illicit drugs. The patient specimens were largely sourced from patients in either a long-term pain management program or in treatment for substance use disorder in the US. These specimens may not be representative of patients in other types of treatment or in countries with different approaches to these issues. The high-sensitivity method reduces false-negative results which could negatively impact patient care. Clinicians using less sensitive methods for detecting and quantifying drugs and metabolites in urine should exercise caution in assessing patient adherence using and changing the treatment plan based on those results. Urine drug testing, patient adherence, clinical toxicology, immunoassay, LC-MS, definitive drug testing, REMS, negative test results, false negative.
Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi
2005-01-01
We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.
Histoplasma Urinary Antigen Testing Obviates the Need for Coincident Serum Antigen Testing.
Libert, Diane; Procop, Gary W; Ansari, Mohammad Q
2018-03-07
Serum and urine antigen (SAg, UAg) detection are common tests for Histoplasma capsulatum. UAg detection is more widely used and reportedly has a higher sensitivity. We investigated whether SAg detection contributes meaningfully to the initial evaluation of patients with suspected histoplasmosis. We reviewed 20,285 UAg and 1,426 SAg tests ordered from 1997 to 2016 and analyzed paired UAg and SAg tests completed on the same patient within 1 week. We determined the positivity rate for each test. Of 601 paired specimens, 542 were concurrent negatives and 48 were concurrent positives (98% agreement). Medical records were available for eight of 11 pairs with discrepant results. UAg was falsely positive in six instances, truly positive once, and falsely negative once. These findings support using a single antigen detection test, rather than both UAg and SAg, as an initial screen for suspected histoplasmosis. This aligns with the current practice of most physicians.
Goldenberg, S D; Cliff, P R; Smith, S; Milner, M; French, G L
2010-01-01
Current diagnosis of Clostridium difficile infection (CDI) relies upon detection of toxins A/B in stool by enzyme immunoassay [EIA(A/B)]. This strategy is unsatisfactory because it has a low sensitivity resulting in significant false negatives. We investigated the performance of a two-step algorithm for diagnosis of CDI using detection of glutamate dehydrogenase (GDH). GDH-positive samples were tested for C. difficile toxin B gene (tcdB) by polymerase chain reaction (PCR). The performance of the two-step protocol was compared with toxin detection by the Meridian Premier EIA kit in 500 consecutive stool samples from patients with suspected CDI. The reference standard among samples that were positive by either EIA(A/B) or GDH testing was culture cytotoxin neutralisation (culture/CTN). Thirty-six (7%) of 500 samples were identified as true positives by culture/CTN. EIA(A/B) identified 14 of the positive specimens with 22 false negatives and two false positives. The two-step protocol identified 34 of the positive samples with two false positives and two false negatives. EIA(A/B) had a sensitivity of 39%, specificity of 99%, positive predictive value of 88% and negative predictive value of 95%. The two-step algorithm performed better, with corresponding values of 94%, 99%, 94% and 99% respectively. Screening for GDH before confirmation of positives by PCR is cheaper than screening all specimens by PCR and is an effective method for routine use. Current EIA(A/B) tests for CDI are of inadequate sensitivity and should be replaced; however, this may result in apparent changes in CDI rates that would need to be explained in national surveillance statistics. Copyright 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
Jeremiah, S S; Balaji, V; Anandan, S; Sahni, R D
2014-01-01
The modified Hodge test (MHT) is widely used as a screening test for the detection of carbapenemases in Gram-negative bacteria. This test has several pitfalls in terms of validity and interpretation. Also the test has a very low sensitivity in detecting the New Delhi metallo-β-lactamase (NDM). Considering the degree of dissemination of the NDM and the growing pandemic of carbapenem resistance, a more accurate alternative test is needed at the earliest. The study intends to compare the performance of the MHT with the commercially available Neo-Sensitabs - Carbapenemases/Metallo-β-Lactamase (MBL) Confirmative Identification pack to find out whether the latter could be an efficient alternative to the former. A total of 105 isolates of Klebsiella pneumoniae resistant to imipenem and meropenem, collected prospectively over a period of 2 years were included in the study. The study isolates were tested with the MHT, the Neo-Sensitabs - Carbapenemases/MBL Confirmative Identification pack and polymerase chain reaction (PCR) for detecting the blaNDM-1 gene. Among the 105 isolates, the MHT identified 100 isolates as carbapenemase producers. In the five isolates negative for the MHT, four were found to produce MBLs by the Neo-Sensitabs. The Neo-Sensitabs did not have any false negatives when compared against the PCR. The MHT can give false negative results, which lead to failure in detecting the carbapenemase producers. Also considering the other pitfalls of the MHT, the Neo-Sensitabs--Carbapenemases/MBL Confirmative Identification pack could be a more efficient alternative for detection of carbapenemase production in Gram-negative bacteria.
Mirandola, Chiara; Toffalini, Enrico; Grassano, Massimo; Cornoldi, Cesare; Melinder, Annika
2014-01-01
The present experiment was conducted to investigate whether negative emotionally charged and arousing content of to-be-remembered scripted material would affect propensity towards memory distortions. We further investigated whether elaboration of the studied material through free recall would affect the magnitude of memory errors. In this study participants saw eight scripts. Each of the scripts included an effect of an action, the cause of which was not presented. Effects were either negatively emotional or neutral. Participants were assigned to either a yes/no recognition test group (recognition), or to a recall and yes/no recognition test group (elaboration + recognition). Results showed that participants in the recognition group produced fewer memory errors in the emotional condition. Conversely, elaboration + recognition participants had lower accuracy and produced more emotional memory errors than the other group, suggesting a mediating role of semantic elaboration on the generation of false memories. The role of emotions and semantic elaboration on the generation of false memories is discussed.
Kozycki, Christina T; Umulisa, Noella; Rulisa, Stephen; Mwikarago, Emil I; Musabyimana, Jean Pierre; Habimana, Jean Pierre; Karema, Corine; Krogstad, Donald J
2017-03-20
Rapid diagnostic tests (RDTs) for histidine rich protein 2 (HRP2) are often used to determine whether persons with fever should be treated with anti-malarials. However, Plasmodium falciparum parasites with a deletion of the hrp2 gene yield false-negative RDTs and there are concerns the sensitivity of HRP2-based RDTs may fall when the intensity of transmission decreases. This observational study enrolled 9226 patients at three health centres in Rwanda from April 2014 to April 2015. It then compared the sensitivity of RDTs based on HRP2 and the Plasmodium lactate dehydrogenase (pLDH) to microscopy (thick smears) for the diagnosis of malaria. PCR was used to determine whether deletions of the histidine-rich central repeat region of the hrp2 gene (exon 2) were associated with false-negative HRP2-based RDTs. In comparison to microscopy, the sensitivity and specificity of HRP2- and pLDH-based RDTs were 89.5 and 86.2% and 80.2 and 94.3%, respectively. When the results for both RDTs were combined, sensitivity rose to 91.8% and specificity was 85.7%. Additionally, when smear positivity fell from 46 to 3%, the sensitivity of the HRP2-based RDT fell from 88 to 67%. Of 370 samples with false-negative HRP2 RDT results for which PCR was performed, 140 (38%) were identified as P. falciparum by PCR. Of the isolates identified as P. falciparum by PCR, 32 (23%) were negative for the hrp2 gene based on PCR. Of the 32 P. falciparum isolates negative for hrp2 by PCR, 17 (53%) were positive based on the pLDH RDT. This prospective study of RDT performance coincided with a decline in the intensity of malaria transmission in Kibirizi (fall in slide positivity from 46 to 3%). This decline was associated with a decrease in HRP2 RDT sensitivity (from 88 to 67%). While P. falciparum isolates without the hrp2 gene were an important cause of false-negative HRP2-based RDTs, most were identified by the pLDH-based RDT. Although WHO does not recommend the use of combined HRP2/pLDH testing in sub-Saharan Africa, these results suggest that combination HRP2/pLDH-based RDTs could reduce the impact of false-negative HRP2-based RDTs for detection of symptomatic P. falciparum malaria.
Cole, Laurence A; Khanlian, Sarah A
2004-05-01
False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 1 2013-10-01 2013-10-01 false What does the MRO do when a valid test result cannot be produced and a negative result is required? 40.160 Section 40.160 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Medical Review Officers and the Verification...
Wang, Jann-Yuan; Lee, Li-Na; Lai, Hsin-Chih; Hsu, Hsiao-Leng; Jan, I-Shiow; Yu, Chong-Jen; Hsueh, Po-Ren; Yang, Pan-Chyr
2007-12-01
Because of the increasing numbers of nontuberculous mycobacterial isolates from clinical specimens, rapid and accurate methods for culture confirmation of Mycobacterium tuberculosis are urgently needed. The study evaluated the performance of the Capilia TB immunochromatographic assay (TAUNS, Numazu, Japan) for culture confirmation of M. tuberculosis using 242 culture-positive liquid media in 2 mycobacterial laboratories from November 2005 to February 2006. Among the 242 samples, 183 were also tested with the BD ProbeTec ET (CTB) assay (Becton Dickinson, Sparks, MD). The results of both assays were compared to the culture results and to each other. The overall sensitivity and specificity of the Capilia TB assay were 98.6% and 97.9%, respectively, and for the CTB assay were 97.3% and 97.1%, respectively. The positive and negative predictive values for the Capilia TB assay were 98.6% and 97.9%, respectively, and for the CTB assay were 98.2% and 95.8%, respectively. Among the 183 samples tested with both assays, 8 had discrepant results, including Capilia-TB-false-positive in 2, CTB-false-positive in another 2, CTB-false-negative in 2, Capilia TB-false-negative in 1, and both assays with false-negative results in the remaining one. This study demonstrated that the Capilia TB assay has a similar diagnostic value with the CTB assay. In addition, with the immunochromatographic method, it is less time-consuming and does not require other laboratory equipment.
[Applying competitive polymerase chain reaction to the detection of hepatitis B virus DNA].
Wang, Ling; Yang, Peng; Li, Shuang-qing; Xu, Shu-hui; Cao, Gui-qun; Zhang, Fa-qiang; Zhang, Mei-xia; Chen, Qing-ying; Xia, Qing-jie; Liu, Kai; Tang, Fang; Zhang, Yuan-zheng
2004-11-01
To reduce the rate of accidental false negative result in the HBV DNA PCR test on clinical serum samples. A competitive polymerase chain reaction (C-PCR) was used to decrease the false negative ratio. In the C-PCR, a constructed inner control DNA was added for co-amplification with the HBV target DNA. In a 20 microl C-PCR system, about 60 to 200 copies of inner control DNA could give apparent co-amplification signal band after electrophoresis on a 2% agarose gel. Five of 120 samples of clinical serum (4.2%) could not be amplified. C-PCR has the advantage of yielding information on false negative in the HBV DNA PCR assay of clinical serum samples.
Fogel, Jessica M; Piwowar-Manning, Estelle; Debevec, Barbara; Walsky, Tamara; Schlusser, Katherine; Laeyendecker, Oliver; Wilson, Ethan A; McCauley, Marybeth; Gamble, Theresa; Tegha, Gerald; Soko, Dean; Kumwenda, Johnstone; Hosseinipour, Mina C; Chen, Ying Q; Cohen, Myron S; Eshleman, Susan H
2017-08-01
Antiretroviral therapy (ART) can downregulate antibody responses to HIV infection. We evaluated the impact of early vs. delayed ART on the performance of HIV diagnostic and incidence assays. Samples were obtained from 207 participants in the HPTN 052 trial, who were stably suppressed on ART for ≥4 years [Malawi sites; pre-ART CD4 cell count 350-550 cells/mm (early ART arm, N = 180) or <250 cells/mm or an AIDS-defining illness (delayed ART arm, N = 27)]. Samples were tested with 2 HIV rapid tests and 2 HIV incidence assays; selected samples were also tested with two fourth-generation immunoassays and a Western blot (WB) assay. A pre-ART sample was analyzed if the follow-up sample had a false-negative or weakly-reactive rapid test result, or had an incidence assay result indicative of recent infection (false-recent result). Ten (4.8%) samples had a nonreactive or weakly-reactive rapid test result (7/180 early ART arm, 3/27 delayed ART arm, P = 0.13); one sample had nonreactive fourth-generation assay results and 3 had indeterminate WBs. Forty (18.9%) samples had a false-recent incidence assay result; 16 (7.8%) had false-recent results with both incidence assays. Baseline samples had stronger rapid test and WB bands, higher fourth-generation assay signal-to-cutoff values, and fewer HIV incidence assay results indicative of recent infection. False-negative/weakly-reactive HIV rapid tests and false-recent HIV incidence assay results were observed in virally-suppressed individuals, regardless of pre-ART CD4 cell count. Downregulation of the antibody response to HIV infection in the setting of ART may impact population-level surveys of HIV prevalence and incidence.
Sabour, Siamak
2018-03-08
The purpose of this letter, in response to Hall, Mehta, and Fackrell (2017), is to provide important knowledge about methodology and statistical issues in assessing the reliability and validity of an audiologist-administered tinnitus loudness matching test and a patient-reported tinnitus loudness rating. The author uses reference textbooks and published articles regarding scientific assessment of the validity and reliability of a clinical test to discuss the statistical test and the methodological approach in assessing validity and reliability in clinical research. Depending on the type of the variable (qualitative or quantitative), well-known statistical tests can be applied to assess reliability and validity. The qualitative variables of sensitivity, specificity, positive predictive value, negative predictive value, false positive and false negative rates, likelihood ratio positive and likelihood ratio negative, as well as odds ratio (i.e., ratio of true to false results), are the most appropriate estimates to evaluate validity of a test compared to a gold standard. In the case of quantitative variables, depending on distribution of the variable, Pearson r or Spearman rho can be applied. Diagnostic accuracy (validity) and diagnostic precision (reliability or agreement) are two completely different methodological issues. Depending on the type of the variable (qualitative or quantitative), well-known statistical tests can be applied to assess validity.
Singh, Gurmukh
2017-01-01
Background Serum free light chain assay (SFLCA) and κ/λ ratio, and protein electrophoretic methods are used in the diagnosis and monitoring of monoclonal gammopathies. Methods Results for serum free light chains, serum and urine protein electrophoreses and immunofixation electrophoreses in 468 patients with a diagnosis of monoclonal gammopathy were compared. The results of the two methods were graded as concordant, non-concordant or discordant with the established diagnoses to assess the relative performance of the methods. Results of κ/λ ratio in samples with monoclonal protein detectable by electrophoretic methods were also analyzed. Results Protein electrophoreses results were concordant with the established diagnoses significantly more often than κ/λ ratio. The false negative rate for κ/λ ratio was higher than that for electrophoretic methods. κ/λ ratio was falsely negative in about 27% of the 1,860 samples with detectable monoclonal immunoglobulin. The false negative rate was higher in lesions with lambda chains (32%) than those with kappa chains (24%). The false negative rate for κ/λ ratio was over 55% in samples with monoclonal gammopathy of undetermined significance. Even at first encounter, the false negative rates for κ/λ ratios for monoclonal gammopathy of undetermined significance, smoldering myeloma and multiple myeloma were 66.98%, 23.08%, and 30.15%, respectively, with false negative rate for lambda chain lesions being higher. Conclusions Electrophoretic studies of serum and urine are superior to SFLCA and κ/λ ratio. Abnormal κ/λ ratio, per se, is not diagnostic of monoclonal gammopathy. A normal κ/λ ratio does not exclude monoclonal gammopathy. False negative rates for lesions with lambda chain are higher than those for lesions with kappa chains. Electrophoretic studies of urine are underutilized. Clinical usefulness and medical necessity of SFLCA and κ/λ ratio is of questionable value in routine clinical testing. PMID:27924175
Singh, Gurmukh
2017-01-01
Serum free light chain assay (SFLCA) and κ/λ ratio, and protein electrophoretic methods are used in the diagnosis and monitoring of monoclonal gammopathies. Results for serum free light chains, serum and urine protein electrophoreses and immunofixation electrophoreses in 468 patients with a diagnosis of monoclonal gammopathy were compared. The results of the two methods were graded as concordant, non-concordant or discordant with the established diagnoses to assess the relative performance of the methods. Results of κ/λ ratio in samples with monoclonal protein detectable by electrophoretic methods were also analyzed. Protein electrophoreses results were concordant with the established diagnoses significantly more often than κ/λ ratio. The false negative rate for κ/λ ratio was higher than that for electrophoretic methods. κ/λ ratio was falsely negative in about 27% of the 1,860 samples with detectable monoclonal immunoglobulin. The false negative rate was higher in lesions with lambda chains (32%) than those with kappa chains (24%). The false negative rate for κ/λ ratio was over 55% in samples with monoclonal gammopathy of undetermined significance. Even at first encounter, the false negative rates for κ/λ ratios for monoclonal gammopathy of undetermined significance, smoldering myeloma and multiple myeloma were 66.98%, 23.08%, and 30.15%, respectively, with false negative rate for lambda chain lesions being higher. Electrophoretic studies of serum and urine are superior to SFLCA and κ/λ ratio. Abnormal κ/λ ratio, per se , is not diagnostic of monoclonal gammopathy. A normal κ/λ ratio does not exclude monoclonal gammopathy. False negative rates for lesions with lambda chain are higher than those for lesions with kappa chains. Electrophoretic studies of urine are underutilized. Clinical usefulness and medical necessity of SFLCA and κ/λ ratio is of questionable value in routine clinical testing.
Antituberculosis IgG Antibodies as a Marker of Active Mycobacterium tuberculosis Disease
Welch, Ryan J.; Lawless, Kathleen M.
2012-01-01
Anti-Mycobacterium tuberculosis IgG antibodies may aid in the diagnosis of active M. tuberculosis disease. We studied whether anti-M. tuberculosis IgG antibodies are elevated in active M. tuberculosis disease and assessed factors contributing to false-positive and -negative results. A retrospective study of 2,150 individuals tested by the QuantiFERON-TB Gold In-Tube (QFT-GIT) assay was conducted at the University of Utah, ARUP Laboratories, November 2008 to December 2010. All samples were tested with the InBios Active TbDetect antituberculosis (anti-TB) IgG antibody assay. Of 1,044 patients with a positive QFT-GIT, 59 (5.7%) were positive for M. tuberculosis antibodies. Fourteen of 1,106 (1.3%) with a negative or indeterminate QFT-GIT were positive for M. tuberculosis antibodies. M. tuberculosis antibody tests were positive in 61.5% with confirmed active M. tuberculosis disease and other mycobacterial infections. Over half of the false-negative M. tuberculosis antibody tests occurred in patients ≥90 years of age. False positives were seen in 12.9% of autoimmune patients. The odds ratio of being positive by the QFT-GIT and the InBios TB IgG assay increased with confirmed M. tuberculosis disease or highly suspected M. tuberculosis disease and was 86.7 (95% confidence interval [CI], 34.4 to 218.5) in these two groups compared to patients negative by both tests. Although anti-M. tuberculosis antibodies can be detected in patients with active M. tuberculosis disease, caution should be used with patients where immunoglobulin levels may be decreased or patients with autoantibodies. PMID:22301692
A critical reappraisal of false negative sentinel lymph node biopsy in melanoma.
Manca, G; Romanini, A; Rubello, D; Mazzarri, S; Boni, G; Chiacchio, S; Tredici, M; Duce, V; Tardelli, E; Volterrani, D; Mariani, G
2014-06-01
Lymphatic mapping and sentinel lymph node biopsy (SLNB) have completely changed the clinical management of cutaneous melanoma. This procedure has been accepted worldwide as a recognized method for nodal staging. SLNB is able to accurately determine nodal basin status, providing the most useful prognostic information. However, SLNB is not a perfect diagnostic test. Several large-scale studies have reported a relatively high false-negative rate (5.6-21%), correctly defined as the proportion of false-negative results with respect to the total number of "actual" positive lymph nodes. The main purpose of this review is to address the technical issues that nuclear physicians, surgeons, and pathologists should carefully consider to improve the accuracy of SLNB by minimizing its false-negative rate. In particular, SPECT/CT imaging has demonstrated to be able to identify a greater number of sentinel lymph nodes (SLNs) than those found by planar lymphoscintigraphy. Furthermore, a unique definition in the international guidelines is missing for the operational identification of SLNs, which may be partly responsible for this relatively high false-negative rate of SLNB. Therefore, it is recommended for the scientific community to agree on the radioactive counting rate threshold so that the surgeon can be better radioguided to detect all the lymph nodes which are most likely to harbor metastases. Another possible source of error may be linked to the examination of the harvested SLNs by conventional histopathological methods. A more careful and extensive SLN analysis (e.g. molecular analysis by RT-PCR) is able to find more positive nodes, so that the false-negative rate is reduced. Older age at diagnosis, deeper lesions, histologic ulceration, head-neck anatomical location of primary lesions are the clinical factors associated with false-negative SLNBs in melanoma patients. There is still much controversy about the clinical significance of a false-negative SLNB on the prognosis of melanoma patients. Indeed, most studies have failed to show that there is worse melanoma-specific survival for false-negative compared to true-positive SLNB patients.
Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Hwang, Jae Jin; Lee, Hyun Joo; Lee, AeRa; Jeong, Yeon Sang; Oh, Sooyeon; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho
2015-06-01
The (13)C-urea breath test ((13)C-UBT) is a noninvasive method for diagnosing Helicobacter pylori (H. pylori) infection. The aims of this study were to evaluate the diagnostic validity of the (13)C-UBT cutoff value and to identify influencing clinical factors responsible for aberrant results. (13)C-UBT (UBiTkit; Otsuka Pharmaceutical, cutoff value: 2.5‰) results in the range 2.0‰ to 10.0‰ after H. pylori eradication therapy were compared with the results of endoscopic biopsy results of the antrum and body. Factors considered to affect test results adversely were analyzed. Among patients with a positive (13)C-UBT result (2.5‰ to 10.0‰, n = 223) or a negative (13)C-UBT result (2.0‰ to < 2.5‰, n = 66) after H. pylori eradication, 73 patients (34.0%) were false positive, and one (1.5%) was false negative as determined by endoscopic biopsy. The sensitivity, specificity, false-positive rate, and false-negative rate for a cutoff value of 2.5‰ were 99.3%, 47.1%, 52.9%, and 0.7%, respectively, and positive and negative predictive values of the (13)C-UBT were 67.3% and 98.5%, respectively. Multivariate analysis showed that a history of two or more previous H. pylori eradication therapies (OR = 2.455, 95%CI = 1.299-4.641) and moderate to severe gastric intestinal metaplasia (OR = 3.359, 95%CI = 1.572-7.178) were associated with a false-positive (13)C-UBT result. The (13)C-UBT cutoff value currently used has poor specificity for confirming H. pylori status after eradication, and this lack of specificity is exacerbated in patients that have undergone multiple prior eradication therapies and in patients with moderate to severe gastric intestinal metaplasia. In addition, the citric-free (13)C-UBT would increase a false-positive (13)C-UBT result. © 2015 John Wiley & Sons Ltd.
The impact of non-concordant self-report of substance use in clinical trials research.
Clark, C Brendan; Zyambo, Cosmas M; Li, Ye; Cropsey, Karen L
2016-07-01
Studies comparing self-report substance use data to biochemical verification generally demonstrate high rates of concordance. We argue that these rates are due to the relatively high true negative rate in the general population, and high degree of honestly in treatment seeking individuals. We hypothesized that high risk individuals not seeking treatment would demonstrate low concordance and a high false negative rate of self-reported substance use. A sample of 500 individuals from a smoking cessation clinical trial was assessed over 1 year. Assessments included semi-structured interviews, questionnaires (e.g. Addiction Severity Index, etc.), and urine drug screen assays (UDS). Generalized estimating equations (GEEs) were used to predict false negative reports for various substances across the study and determine the influence of substance use on the primary study outcome of smoking cessation. Participants demonstrated high false negative rates in reporting substances use, and the false negative rates increased as the study progressed. Established predictors of false negatives generalized to the current sample. High concordance and low false negative rates were found in self-report of nicotine use. A small but significant relationship was found in for effect of biochemically verified substance use on smoking cessation. Biochemical verification of substance use is needed in high risk populations involved in studies not directly related to the treatment of substance use, especially in populations with high threat of stigmatization. Testing should continue through the time period of the study for maximal identification of substance use. Copyright © 2016 Elsevier Ltd. All rights reserved.
False-negative dipyridamole-thallium-201 myocardial imaging after caffeine infusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smits, P.; Corstens, F.H.; Aengevaeren, W.R.
1991-08-01
The vasodilator effect of intravenously administered dipyridamole may be caused by an increase in endogenous plasma adenosine levels. The authors evaluated the effect of caffeine, an adenosine receptor antagonist, on the diagnostic results of dipyridamole-201Tl myocardial imaging in eight patients with coronary artery disease. Caffeine infusion significantly attenuated the dipyridamole-induced fall in blood pressure and the accompanied increase in heart rate. The infusion of dipyridamole alone resulted in chest pain and ST-segment depressions on the electrocardiogram in four patients, whereas none of these problems occurred when the tests were repeated after caffeine. In six of eight patients, caffeine was responsiblemore » for false-negative dipyridamole-201Tl tests. Semiquantitive scores of the dipyridamole-induced 201Tl perfusion defects were decreased by caffeine from 9.0 {plus minus} 0.9 to 2.0 {plus minus} 1.1 points (p less than 0.05). Computerized analysis revealed a caffeine-mediated reduction in the percent reversibility of the images from 46% {plus minus} 16% to 6% {plus minus} 10% (p less than 0.05). They conclude that the use of caffeinated products prior to dipyridamole-201Tl testing may be responsible for false-negative findings.« less
Taylor, Michelle; Sullivan, John; Ring, Susan M; Macleod, John; Hickman, Matthew
2017-03-01
We investigate the extent of and factors associated with denial of previously reported cannabis and other illicit drug use, and assess the potential of hair testing for measuring substance use in general population samples. Birth cohort study. United Kingdom, 1991-present. A total of 3643 participants who provided hair and self-report measures of cannabis and other illicit drug use in the Avon Longitudinal Study of Parents and Children (ALSPAC) at age 18 years. Denial of ever use of cannabis and other illicit drugs at age 18 following previously reported use. Positive hair drug tests for cannabis and other illicit drugs, and expected numbers of false positives and false negatives based on expected sensitivity and specificity. Cannabis and other illicit drug use was reported by 1223 and 393 individuals, respectively, before age 18 years. Of these 176 (14.4%) and 99 (25.2%), respectively, denied use at age 18. Denial of cannabis use decreased with the reporting of other substances and antisocial behaviour. Cannabis and other illicit drug use at age 18 was reported by 547 (22.5%) and 203 (8.4%) individuals, respectively. Of these, 111 (20.3%) and 13 (6.4%) were hair-positive for cannabis and other illicit drugs, respectively. Based on hair testing for cannabis use we expect 0 [95% confidence interval (CI) = 0-169] false positives and 394 (95% CI = 323-449) false negatives compared to observed 362 potential false positives and 436 potential false negatives based on self-report. In hair-positive individuals, reporting the use of other substances and antisocial behaviour decreased the odds of a negative self-report. Hair analysis provides an unreliable marker of substance use in general population samples. People who report more frequent substance use before age 18 are less likely to later deny previous substance use at age 18 than people who report occasional use. © 2016 The Authors. Addiction published by John Wiley & Sons Ltd on behalf of Society for the Study of Addiction.
Sullivan, John; Ring, Susan M.; Macleod, John; Hickman, Matthew
2016-01-01
Abstract Aims We investigate the extent of and factors associated with denial of previously reported cannabis and other illicit drug use, and assess the potential of hair testing for measuring substance use in general population samples. Design Birth cohort study. Setting United Kingdom, 1991–present. Participants A total of 3643 participants who provided hair and self‐report measures of cannabis and other illicit drug use in the Avon Longitudinal Study of Parents and Children (ALSPAC) at age 18 years. Measurements Denial of ever use of cannabis and other illicit drugs at age 18 following previously reported use. Positive hair drug tests for cannabis and other illicit drugs, and expected numbers of false positives and false negatives based on expected sensitivity and specificity. Findings Cannabis and other illicit drug use was reported by 1223 and 393 individuals, respectively, before age 18 years. Of these 176 (14.4%) and 99 (25.2%), respectively, denied use at age 18. Denial of cannabis use decreased with the reporting of other substances and antisocial behaviour. Cannabis and other illicit drug use at age 18 was reported by 547 (22.5%) and 203 (8.4%) individuals, respectively. Of these, 111 (20.3%) and 13 (6.4%) were hair‐positive for cannabis and other illicit drugs, respectively. Based on hair testing for cannabis use we expect 0 [95% confidence interval (CI) = 0–169] false positives and 394 (95% CI = 323–449) false negatives compared to observed 362 potential false positives and 436 potential false negatives based on self‐report. In hair‐positive individuals, reporting the use of other substances and antisocial behaviour decreased the odds of a negative self‐report. Conclusions Hair analysis provides an unreliable marker of substance use in general population samples. People who report more frequent substance use before age 18 are less likely to later deny previous substance use at age 18 than people who report occasional use. PMID:27743424
Moesker, F M; van Kampen, J J A; Aron, G; Schutten, M; van de Vijver, D A M C; Koopmans, M P G; Osterhaus, A D M E; Fraaij, P L A
2016-06-01
Rapid antigen detection tests (RADTs) are increasingly used to detect influenza viruses and respiratory syncytial virus (RSV). However, their sensitivity and specificity are a matter of debate, challenging their clinical usefulness. Comparing diagnostic performances of BinaxNow Influenza AB(®) (BNI) and BinaxNow RSV(®) (BNR), to those of real-time reverse transcriptase PCR (RT-PCR), virus isolation and direct immunofluorescence (D-IF) in paediatric patients. Between November 2005 and September 2013, 521 nasal washings from symptomatic children (age <5 years) attending our tertiary care centre were tested, with a combination of the respective assays using RT-PCR as gold standard. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of BNI were 69% (confidence interval [CI] [51-83]), 96% [94-97], 55% [39-70] and 98% [96-99] respectively. Of eleven false-negative samples, RT-PCR Ct-values were higher than all RT-PCR positive test results (27 vs 22, p=0.012). Of twenty false-positive samples, none were culture positive and two tested positive in D-IF. Sensitivity, specificity, PPV and NPV for BNR were 79% [73-85], 98% [96-99], 97% [93-99] and 88% [84-91]. Of the 42 false-negative samples the median Ct-value was higher than that of all RT-PCR positive samples (31 vs 23, p<0.0001). Five false-positive samples were detected. Three of these tested positive for RSV in virus isolation and D-IF. RADTs have a high specificity with BNR being superior to BNI. However, their relative low sensitivity limits their usefulness for clinical decision making in a tertiary care paediatric hospital. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Laboratory and clinical evaluation of on-site urine drug testing.
Beck, Olof; Carlsson, Sten; Tusic, Marinela; Olsson, Robert; Franzen, Lisa; Hulten, Peter
2014-11-01
Products for on-site urine drug testing offer the possibility to perform screening for drugs of abuse directly at the point-of-care. This is a well-established routine in emergency and dependency clinics but further evaluation of performance is needed due to inherent limitations with the available products. Urine drug testing by an on-site product was compared with routine laboratory methods. First, on-site testing was performed at the laboratory in addition to the routine method. Second, the on-site testing was performed at a dependency clinic and urine samples were subsequently sent to the laboratory for additional analytical investigation. The on-site testing products did not perform with assigned cut-off levels. The subjective reading between the presence of a spot (i.e. negative test result) being present or no spot (positive result) was difficult in 3.2% of the cases, and occurred for all parameters. The tests performed more accurately in drug negative samples (specificity 96%) but less accurately for detecting positives (sensitivity 79%). Of all incorrect results by the on-site test the proportion of false negatives was 42%. The overall agreement between on-site and laboratory testing was 95% in the laboratory study and 98% in the clinical study. Although a high degree of agreement was observed between on-site and routine laboratory urine drug testing, the performance of on-site testing was not acceptable due to significant number of false negative results. The limited sensitivity of on-site testing compared to laboratory testing reduces the applicability of these tests.
Wu, Shan; Zhang, Xiaofeng; Shuai, Jiangbing; Li, Ke; Yu, Huizhen; Jin, Chenchen
2016-07-04
To simplify the PNA-FISH (Peptide nucleic acid-fluorescence in situ hybridization) test, molecular beacon based PNA probe combined with fluorescence scanning detection technology was applied to replace the original microscope observation to detect Listeria monocytogenes The 5′ end and 3′ end of the L. monocytogenes specific PNA probes were labeled with the fluorescent group and the quenching group respectively, to form a molecular beacon based PNA probe. When PNA probe used for fluorescence scanning and N1 treatment as the control, the false positive rate was 11.4%, and the false negative rate was 0; when N2 treatment as the control, the false positive rate decreased to 4.3%, but the false negative rate rose to 18.6%. When beacon based PNA probe used for fluorescence scanning, taken N1 treatment as blank control, the false positive rate was 8.6%, and the false negative rate was 1.4%; taken N2 treatment as blank control, the false positive rate was 5.7%, and the false negative rate was 1.4%. Compared with PNA probe, molecular beacon based PNA probe can effectively reduce false positives and false negatives. The success rates of hybridization of the two PNA probes were 83.3% and 95.2% respectively; and the rates of the two beacon based PNA probes were 91.7% and 90.5% respectively, which indicated that labeling the both ends of the PNA probe dose not decrease the hybridization rate with the target bacteria. The combination of liquid phase PNA-FISH and fluorescence scanning method, can significantly improve the detection efficiency.
Positive events protect children from causal false memories for scripted events.
Melinder, Annika; Toffalini, Enrico; Geccherle, Eleonora; Cornoldi, Cesare
2017-11-01
Adults produce fewer inferential false memories for scripted events when their conclusions are emotionally charged than when they are neutral, but it is not clear whether the same effect is also found in children. In the present study, we examined this issue in a sample of 132 children aged 6-12 years (mean 9 years, 3 months). Participants encoded photographs depicting six script-like events that had a positively, negatively, or a neutral valenced ending. Subsequently, true and false recognition memory of photographs related to the observed scripts was tested as a function of emotionality. Causal errors-a type of false memory thought to stem from inferential processes-were found to be affected by valence: children made fewer causal errors for positive than for neutral or negative events. Hypotheses are proposed on why adults were found protected against inferential false memories not only by positive (as for children) but also by negative endings when administered similar versions of the same paradigm.
Can missed breast cancer be recognized by regular peer auditing on screening mammography?
Pan, Huay-Ben; Yang, Tsung-Lung; Hsu, Giu-Cheng; Chiang, Chia-Ling; Huang, Jer-Shyung; Chou, Chen-Pin; Wang, Yen-Chi; Liang, Huei-Lung; Lee, San-Kan; Chou, Yi-Hong; Wong, Kam-Fai
2012-09-01
This study was conducted to investigate whether detectable missed breast cancers could be distinguished from truly false negative images in a mammographic screening by a regular peer auditing. Between 2004 and 2007, a total of 311,193 free nationwide biennial mammographic screenings were performed for 50- to 69-year-old women in Taiwan. Retrospectively comparing the records in Taiwan's Cancer registry, 1283 cancers were detected (4.1 per 1000). Of the total, 176 (0.6 per 1000) initial mammographic negative assessments were reported to have cancers (128 traditional films and 48 laser-printed digital images). We selected 186 true negative films (138 traditional films and 48 laser-printed ones) as control group. These were seeded into 4815 films of 2008 images to be audited in 2009. Thirty-four auditors interpreted all the films in a single-blind, randomized, pair-control study. The performance of 34 auditors was analyzed by chi-square test. A p value of < 0.05 was considered significant. Eight (6 traditional and 2 digital films) of the 176 false negative films were not reported by the auditors (missing rate of 4.5%). Of this total, 87 false negatives were reassessed as positive, while 29 of the 186 true negatives were reassessed as positive, making the overall performance of the 34 auditors in interpreting the false negatives and true negatives a specificity of 84.4% and sensitivity of 51.8%. The specificity and sensitivity in traditional films and laser-printed films were 98.6% versus 43.8% and 41.8% versus 78.3%, respectively. Almost 42% of the traditional false negative films had positive reassessment by the auditors, showing a significant difference from the initial screeners (p < 0.001). The specificity of their reinterpretation of laser-printed films was obviously low. Almost 42% of the false negative traditional films were judged as missed cancers in this study. A peer auditing should reduce the probability of missed cancers. 2012 Published by Elsevier B.V
False-Positive Cryptococcal Antigen Test Associated with Use of BBL Port-A-Cul Transport Vials▿
Wilson, Deborah A.; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S.; Procop, Gary W.
2011-01-01
A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed. PMID:21159939
False-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.
Wilson, Deborah A; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S; Procop, Gary W
2011-02-01
A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed.
Cliquet, F; McElhinney, L M; Servat, A; Boucher, J M; Lowings, J P; Goddard, T; Mansfield, K L; Fooks, A R
2004-04-01
A protocol suitable for the detection of rabies virus-specific antibodies in serum samples from companion animals using an enzyme linked immunosorbent assay (ELISA) is described. This method has been used successfully for the qualitative assessment of rabies virus-specific antibodies in serum samples from a cohort of vaccinated dogs and cats. In two initial field studies, a variable population of field samples from the Veterinary Laboratories Agency (VLA), United Kingdom were tested. In the first study (n = 1000), the number of false-positive and false-negative results was 11 samples (1.1%) and 67 samples (6.7%), respectively. In the second study (n = 920), the number of false-positive and false-negative results was 7 samples (0.8%) and 52 samples (5.7%). In a third study, undertaken at l'Agence Française de Sécurité Sanitaire des Aliments (AFSSA), Nancy, France (n = 440), 1 false-positive sample (0.23%) and 91 (20.7%) false-negative samples were identified. Data generated using this prototype ELISA indicate a strong correlation for specificity when compared to the gold standard fluorescent antibody virus neutralisation (FAVN) test. Although the ELISA has a lower sensitivity than the FAVN test, it is a useful tool for rapidly screening serum samples from vaccinated companion animals. Using a cut-off value of 0.6 EU/ml, the sensitivity (R = % from VLA and 79% from AFSSA) and specificity (R = 97.3%) indices between the ELISA compared favourably with data generated using the FAVN test. The major advantages of the ELISA test are that it is a qualitative tool that can be completed in four hours, does not require the use of live virus and can be performed without the need for specialised laboratory containment. This contrasts with 4 days using conventional rabies antibody virus neutralisation assays. Using the current format, the ELISA assay described would be a valuable screening tool for the detection of rabies antibodies from vaccinated domestic animals in combination with other Office International des Epizooties (OIE) accepted serological tests.
Sociopathic Knowledge Bases: Correct Knowledge Can Be Harmful Even Given Unlimited Computation
1989-08-01
pobitive, as false positives generated by a medical program can often be caught by a physician upon further testing . False negatives, however, may be...improvement over the knowledge base tested is obtained. Although our work is pretty much theoretical research oriented one example of ex- periments is...knowledge base, improves the performance by about 10%. of tests . First, we divide the cases into a training set and a validation set with 70% vs. 30% each
Current methodological issues in the economic assessment of personalized medicine.
Annemans, Lieven; Redekop, Ken; Payne, Katherine
2013-01-01
There is a need for methodological scrutiny in the economic assessment of personalized medicine. In this article, we present a list of 10 specific issues that we argue pose specific methodological challenges that require careful consideration when designing and conducting robust model-based economic evaluations in the context of personalized medicine. Key issues are related to the correct framing of the research question, interpretation of test results, data collection of medical management options after obtaining test results, and expressing the value of tests. The need to formulate the research question clearly and be explicit and specific about the technology being evaluated is essential because various test kits can have the same purpose and yet differ in predictive value, costs, and relevance to practice and patient populations. The correct reporting of sensitivity/specificity, and especially the false negatives and false positives (which are population dependent), of the investigated tests is also considered as a key element. This requires additional structural complexity to establish the relationship between the test result and the consecutive treatment changes and outcomes. This process involves translating the test characteristics into clinical utility, and therefore outlining the clinical and economic consequences of true and false positives and true and false negatives. Information on treatment patterns and on their costs and outcomes, however, is often lacking, especially for false-positive and false-negative test results. The analysis can even become very complex if different tests are combined or sequentially used. This potential complexity can be handled by explicitly showing how these tests are going to be used in practice and then working with the combined sensitivities and specificities of the tests. Each of these issues leads to a higher degree of uncertainty in economic models designed to assess the added value of personalized medicine compared with their simple pharmaceutical counterparts. To some extent, these problems can be overcome by performing early population-level simulations, which can lead to the identification and collection of data on critical input parameters. Finally, it is important to understand that a test strategy does not necessarily lead to more quality-adjusted life-years (QALYs). It is possible that the test will lead to not only fewer QALYs but also fewer costs, which can be defined as "decremental" cost per QALYs. Different decision criteria are needed to interpret such results. © 2013 Published by Elsevier Inc. on behalf of International Society for Pharmacoeconomics and Outcomes Research (ISPOR).
Risk of breast cancer after false-positive results in mammographic screening.
Román, Marta; Castells, Xavier; Hofvind, Solveig; von Euler-Chelpin, My
2016-06-01
Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level data from the population-based screening programs in Copenhagen and Funen in Denmark, Norway, and Spain. Overall, 150,383 screened women from Denmark (1991-2008), 612,138 from Norway (1996-2010), and 1,172,572 from Spain (1990-2006) were included. Poisson regression was used to estimate the relative risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50-69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1.4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93-2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77-1.96), whereas those who tested false-positive at third screening had a RR of 2.42 (95% CI: 2.21-2.64). The RR of breast cancer at the screening test after the false-positive result was 3.95 (95% CI: 3.71-4.21), whereas it decreased to 1.25 (95% CI: 1.17-1.34) three or more screens after the false-positive result. Women with false-positive results had a twofold risk of screen-detected breast cancer compared to women with negative tests. The risk remained significantly higher three or more screens after the false-positive result. The increased risk should be considered when discussing stratified screening strategies. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
de Haas, Masja; Thurik, Florentine F; van der Ploeg, Catharina P B; Veldhuisen, Barbera; Hirschberg, Hoang; Soussan, Aicha Ait; Woortmeijer, Heleen; Abbink, Frithjofna; Page-Christiaens, Godelieve C M L; Scheffer, Peter G; Ellen van der Schoot, C
2016-11-07
To determine the accuracy of non-invasive fetal testing for the RHD gene in week 27 of pregnancy as part of an antenatal screening programme to restrict anti-D immunoglobulin use to women carrying a child positive for RHD DESIGN: Prospectively monitoring of fetal RHD testing accuracy compared with serological cord blood typing on introduction of the test. Fetal RHD testing was performed with a duplex real time quantitative polymerase chain reaction, with cell-free fetal DNA isolated from 1 mL of maternal plasma The study period was between 4 July 2011 and 7 October 2012. The proportion of women participating in screening was determined. Nationwide screening programme, the Netherlands. Tests are performed in a centralised setting. 25 789 RhD negative pregnant women. Sensitivity, specificity, false negative rate, and false positive rate of fetal RHD testing compared with serological cord blood typing; proportion of technical failures; and compliance to the screening programme. A fetal RHD test result and serological cord blood result were available for 25 789 pregnancies. Sensitivity for detection of fetal RHD was 99.94% (95% confidence interval 99.89% to 99.97%) and specificity was 97.74% (97.43% to 98.02%). Nine false negative results for fetal RHD testing were registered (0.03%, 95% confidence interval 0.01% to 0.06%). In two cases these were due to technical failures. False positive fetal RHD testing results were registered for 225 samples (0.87%, 0.76% to 0.99%). Weak RhD expression was shown in 22 of these cases, justifying anti-D immunoglobulin use. The negative and positive predictive values were 99.91% (95% confidence interval 99.82% to 99.95%) and 98.60% (98.40% to 98.77%), respectively. More than 98% of the women participated in the screening programme. Fetal RHD testing in week 27 of pregnancy as part of a national antenatal screening programme is highly reliable and can be used to target both antenatal and postnatal anti-D immunoglobulin use. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Mehta, Sanjay R; MacGruder, Cathy; Looney, David; Johns, Scott; Smith, Davey M
2009-04-01
In response to a difference in pricing, the San Diego Veterans Administration Medical Center changed its tuberculin preparation from Tubersol to Aplisol in the fall of 2006. Following the change, an increased number of employee skin test conversions was noted. Employee tuberculin skin test converters from 2006 were screened with the QuantiFERON Gold (QFT-G) gamma interferon release assay. Those employees who tested negative by QFT-G were asked to repeat their skin test with both Tubersol and Aplisol tuberculin preparations. Of the new purified protein derivative converters, 12 of 14 returned for repeat testing with QFT-G, and the assay was negative for 83% (10/12), positive for 8% (1/12), and indeterminate for 8% (1/12) of the individuals. Nine of the individuals who were QFT-G negative agreed to repeat skin testing with both tuberculin preparations, and 7/8 (87.5%) demonstrated reactivity with the Aplisol preparation, while 0/8 (0%) reacted to the Tubersol preparation. A change from Tubersol to Aplisol resulted in elevated tuberculin skin test conversion rates that may be due to false-positive reactions. The differences in skin test reactivity between preparations support CDC guidelines that recommend that institutions should not change tuberculin preparations, as doing so may falsely increase the number of positive reactions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 33 2013-07-01 2013-07-01 false Test results. 799.12 Section 799.12... results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or negative test result in any of the tests required under subpart B is defined in the TSCA test guidelines...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 33 2012-07-01 2012-07-01 false Test results. 799.12 Section 799.12... results. Except as set forth in specific chemical test rules in subpart B of this part, a positive or negative test result in any of the tests required under subpart B is defined in the TSCA test guidelines...
An empirical probability model of detecting species at low densities.
Delaney, David G; Leung, Brian
2010-06-01
False negatives, not detecting things that are actually present, are an important but understudied problem. False negatives are the result of our inability to perfectly detect species, especially those at low density such as endangered species or newly arriving introduced species. They reduce our ability to interpret presence-absence survey data and make sound management decisions (e.g., rapid response). To reduce the probability of false negatives, we need to compare the efficacy and sensitivity of different sampling approaches and quantify an unbiased estimate of the probability of detection. We conducted field experiments in the intertidal zone of New England and New York to test the sensitivity of two sampling approaches (quadrat vs. total area search, TAS), given different target characteristics (mobile vs. sessile). Using logistic regression we built detection curves for each sampling approach that related the sampling intensity and the density of targets to the probability of detection. The TAS approach reduced the probability of false negatives and detected targets faster than the quadrat approach. Mobility of targets increased the time to detection but did not affect detection success. Finally, we interpreted two years of presence-absence data on the distribution of the Asian shore crab (Hemigrapsus sanguineus) in New England and New York, using our probability model for false negatives. The type of experimental approach in this paper can help to reduce false negatives and increase our ability to detect species at low densities by refining sampling approaches, which can guide conservation strategies and management decisions in various areas of ecology such as conservation biology and invasion ecology.
The positive and negative consequences of multiple-choice testing.
Roediger, Henry L; Marsh, Elizabeth J
2005-09-01
Multiple-choice tests are commonly used in educational settings but with unknown effects on students' knowledge. The authors examined the consequences of taking a multiple-choice test on a later general knowledge test in which students were warned not to guess. A large positive testing effect was obtained: Prior testing of facts aided final cued-recall performance. However, prior testing also had negative consequences. Prior reading of a greater number of multiple-choice lures decreased the positive testing effect and increased production of multiple-choice lures as incorrect answers on the final test. Multiple-choice testing may inadvertently lead to the creation of false knowledge.
Evaluation of recombinant proteins of Burkholderia mallei for serodiagnosis of glanders.
Pal, Vijai; Kumar, Subodh; Malik, Praveen; Rai, Ganga Prasad
2012-08-01
Glanders is a contagious disease caused by the Gram-negative bacillus Burkholderia mallei. The number of equine glanders outbreaks has increased steadily during the last decade. The disease must be reported to the Office International des Epizooties, Paris, France. Glanders serodiagnosis is hampered by the considerable number of false positives and negatives of the internationally prescribed tests. The major problem leading to the low sensitivity and specificity of the complement fixation test (CFT) and enzyme-linked immunosorbent assay (ELISA) has been linked to the test antigens currently used, i.e., crude preparations of whole cells. False-positive results obtained from other diagnostic tests utilizing crude antigens lead to financial losses to animal owners, and false-negative results can turn a risk into a possible threat. In this study, we report on the identification of diagnostic targets using bioinformatics tools for serodiagnosis of glanders. The identified gene sequences were cloned and expressed as recombinant proteins. The purified recombinant proteins of B. mallei were used in an indirect ELISA format for serodiagnosis of glanders. Two recombinant proteins, 0375H and 0375TH, exhibited 100% sensitivity and specificity for glanders diagnosis. The proteins also did not cross-react with sera from patients with the closely related disease melioidosis. The results of this investigation highlight the potential of recombinant 0375H and 0375TH proteins in specific and sensitive diagnosis of glanders.
Evaluation of Recombinant Proteins of Burkholderia mallei for Serodiagnosis of Glanders
Kumar, Subodh; Malik, Praveen
2012-01-01
Glanders is a contagious disease caused by the Gram-negative bacillus Burkholderia mallei. The number of equine glanders outbreaks has increased steadily during the last decade. The disease must be reported to the Office International des Epizooties, Paris, France. Glanders serodiagnosis is hampered by the considerable number of false positives and negatives of the internationally prescribed tests. The major problem leading to the low sensitivity and specificity of the complement fixation test (CFT) and enzyme-linked immunosorbent assay (ELISA) has been linked to the test antigens currently used, i.e., crude preparations of whole cells. False-positive results obtained from other diagnostic tests utilizing crude antigens lead to financial losses to animal owners, and false-negative results can turn a risk into a possible threat. In this study, we report on the identification of diagnostic targets using bioinformatics tools for serodiagnosis of glanders. The identified gene sequences were cloned and expressed as recombinant proteins. The purified recombinant proteins of B. mallei were used in an indirect ELISA format for serodiagnosis of glanders. Two recombinant proteins, 0375H and 0375TH, exhibited 100% sensitivity and specificity for glanders diagnosis. The proteins also did not cross-react with sera from patients with the closely related disease melioidosis. The results of this investigation highlight the potential of recombinant 0375H and 0375TH proteins in specific and sensitive diagnosis of glanders. PMID:22695165
DOT National Transportation Integrated Search
1974-05-01
A resting 'normal' ECG can coexist with known angina pectoris, positive angiocardiography and previous myocardial infarction. In contemporary exercise ECG tests, a false positive/false negative total error of 10% is not unusual. Research aimed at imp...
Pomes, M.L.; Thurman, E.M.; Aga, D.S.; Goolsby, D.A.
1998-01-01
Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false- positive rate of 11.8% and the chloroacetanilide ELISA yielded a false- negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.Triazine and chloroacetanilide concentrations in rainfall samples collected from a 23-state region of the United States were analyzed with microtiter-plate enzyme-linked immunosorbent assay (ELISA). Thirty-six percent of rainfall samples (2072 out of 5691) were confirmed using gas chromatography/mass spectrometry (GC/MS) to evaluate the operating performance of ELISA as a screening test. Comparison of ELISA to GC/MS results showed that the two ELISA methods accurately reported GC/MS results (m = 1), but with more variability evident with the triazine than with the chloroacetanilide ELISA. Bayes's rule, a standardized method to report the results of screening tests, indicated that the two ELISA methods yielded comparable predictive values (80%), but the triazine ELISA yielded a false-positive rate of 11.8% and the chloroacetanilide ELISA yielded a false-negative rate of 23.1%. The false-positive rate for the triazine ELISA may arise from cross reactivity with an unknown triazine or metabolite. The false-negative rate of the chloroacetanilide ELISA probably resulted from a combination of low sensitivity at the reporting limit of 0.15 ??g/L and a distribution characterized by 75% of the samples at or below the reporting limit of 0.15 ??g/L.
40 CFR 745.88 - Recognized test kits.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...
40 CFR 745.88 - Recognized test kits.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...
40 CFR 745.88 - Recognized test kits.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...
40 CFR 745.88 - Recognized test kits.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...
Nakhoul, Georges N; Hickner, John
2013-06-01
Rapid antigen detection tests (RADT) are commonly used to guide appropriate antibiotic treatment of group A beta-hemolytic streptococcal (GABHS) pharyngitis. In adults, there is controversy about the need for routine backup testing of negative RADT. Estimate the costs and benefits in adults of routine backup testing by DNA Gen-probe of negative RADT (Acceava). Observational follow-up study. All patients aged 18 years and older visiting a Cleveland Clinic generalist physician in 2009 and 2010 with a visit diagnosis of acute pharyngitis (ICD codes 462, 034.0). The patients were identified using the Cleveland Clinic Epic Clarity database. We determined the proportion of false negative RADT, antibiotic prescription patterns and rate of serious suppurative complications within 30 days of the office visit. Of 25,130 patients with acute pharyngitis, 19% had no testing and 81% were tested. Of the 15,555 patients that had a negative RADT and follow-up DNA probe, 6% had a positive DNA probe. Of the 953 patients who had a negative RADT and a positive DNA strep probe, 48% received an antibiotic prescription at the time of the visit and 51% received an antibiotic prescription after an average of 2.3 days. Only one patient with a negative RADT and no follow-up DNA probe developed a peritonsillar abscess. Overall, of the 15,555 DNA probes performed, management was altered in only 3% of the patients at a total cost of $1,757,715. Fifty-six percent received an antibiotic while only 19.5% had a confirmed strep throat diagnosis. The false negative rate of Acceava RADT for the diagnosis of GABHS pharyngitis was 6%. We question the benefit of routine DNA probe backup testing in adults because of its substantial cost, an average delay in antibiotic prescribing of over 2 days, and because suppurative complications are very uncommon. We found a high rate of inappropriate antibiotic prescribing.
Miles, Anne; Rodrigues, Vania; Sevdalis, Nick
2013-11-01
To examine the impact of numeric risk information about false negative (FN) and false positive (FP) rates in faecal occult blood testing (FOBt) on attitudes towards screening. 95 people aged 45-59, living in England, read 6 hypothetical vignettes presented online about the use of FOB testing to detect bowel cancer, in which information about FN and FP rates was systematically varied. Both verbal and numeric FN risk information reduced people's interest in screening compared with no FN information. Numeric FN risk information reduced people's perceptions of screening effectiveness and lowered perceived trust in the results of screening compared with both verbal FN information and no FN information. FP information did not affect attitudes towards FOB testing. There was limited evidence that FN information reduced interest and perceptions of screening effectiveness more in educated groups. Numeric FN risk information decreased people's perceptions of screening effectiveness and trust in the results of screening but did not affect people's interest in screening anymore than verbal FN risk information. Numeric FN information could be added to patient information without affecting interest in screening, although this needs to be replicated in a larger, more representative sample. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Pan, Liping; Jia, Hongyan; Liu, Fei; Sun, Huishan; Gao, Mengqiu; Du, Fengjiao; Xing, Aiying; Du, Boping; Sun, Qi; Wei, Rongrong; Gu, Shuxiang; Zhang, Zongde
2015-04-01
To investigate the risk factors for false-negative T-SPOT.TB results in patients with pulmonary TB (PTB) and extra-pulmonary TB (EPTB). Patients with suspected TB who underwent valid T-SPOT.TB tests were prospectively enrolled at Beijing Chest Hospital between November 2012 and November 2013. Basic characters and clinical laboratory findings were compared between true-positive and false-negative T-SPOT.TB groups. Of 1928 suspected TB patients, 774 (530 PTB and 244 EPTB) microbiologically/histopathogenically-confirmed patients (636 culture-confirmed) were analyzed. Forty-six PTB patients (8.7%) and 32 EPTB patients (13.1%) had negative T-SPOT.TB results. Multivariate analysis showed that increased age [odds radio (OR) 2.26, 95% confidence interval (CI) 1.11-4.58], over-weight (BMI ≥ 25 kg/m(2), OR 2.43, 95% CI 1.05-5.63), and a longer period of illness before hospitalization (>6 months, OR 2.46, 95% CI 1.24-4.92) were independent risk factors for false-negative T-SPOT.TB results in PTB patients. In EPTB patients, increased age (OR 2.42, 95% CI 1.09-5.35) also showed an independent association with false-negative T-SPOT.TB results. Careful interpretation of negative T-SPOT.TB results is necessary in older patients with suspected PTB or EPTB, and in PTB patients who are over-weight or have had longer periods of illness before hospitalization. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
Rath, S; Panda, M; Sahu, M C; Padhy, R N
2015-09-01
Quantitatively, conventional methods of diagnosis of tinea capitis or paediatric ringworm, microscopic and culture tests were evaluated with Bayes rule. This analysis would help in quantifying the pervasive errors in each diagnostic method, particularly the microscopic method, as a long-term treatment would be involved to eradicate the infection by the use of a particular antifungal chemotherapy. Secondly, the analysis of clinical data would help in obtaining digitally the fallible standard of the microscopic test method, as the culture test method is taken as gold standard. Test results of 51 paediatric patients were of 4 categories: 21 samples were true positive (both tests positive), and 13 were true negative; the rest samples comprised both 14 false positive (microscopic test positivity with culture test negativity) and 3 false negative (microscopic test negativity with culture test positivity) samples. The prevalence of tinea infection was 47.01% in the population of 51 children. The microscopic test of a sample was efficient by 87.5%, in arriving at a positive result on diagnosis, when its culture test was positive; and, this test was efficient by 76.4%, in arriving at a negative result, when its culture test was negative. But, the post-test probability value of a sample with both microscopic and culture tests would be correct in distinguishing a sample from a sick or a healthy child with a chance of 71.5%. However, since the sensitivity of the analysis is 87.5%, the microscopic test positivity would be easier to detect in the presence of infection. In conclusion, it could be stated that Trychophyton rubrum was the most prevalent species; sensitivity and specificity of treating the infection, by antifungal therapy before ascertaining by the culture method remain as 0.8751 and 0.7642, respectively. A correct/coveted diagnostic method of fungal infection would be could be achieved by modern molecular methods (matrix-assisted laser desorption ionisation-time of flight mass spectrometry or fluorescence in situ hybridization or enzyme-linked immunosorbent assay [ELISA] or restriction fragment length polymorphism or DNA/RNA probes of known fungal taxa) in advanced laboratories. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
40 CFR 745.88 - Recognized test kits.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have... publicizes its recognition of the first test kit that meets both the negative response and positive response...
Do the benefits outweigh the side effects of colorectal cancer surveillance? A systematic review.
Augestad, Knut Magne; Rose, Johnie; Crawshaw, Benjamin; Cooper, Gregory; Delaney, Conor
2014-05-15
Most patients treated with curative intent for colorectal cancer (CRC) are included in a follow-up program involving periodic evaluations. The survival benefits of a follow-up program are well delineated, and previous meta-analyses have suggested an overall survival improvement of 5%-10% by intensive follow-up. However, in a recent randomized trial, there was no survival benefit when a minimal vs an intensive follow-up program was compared. Less is known about the potential side effects of follow-up. Well-known side effects of preventive programs are those of somatic complications caused by testing, negative psychological consequences of follow-up itself, and the downstream impact of false positive or false negative tests. Accordingly, the potential survival benefits of CRC follow-up must be weighed against these potential negatives. The present review compares the benefits and side effects of CRC follow-up, and we propose future areas for research.
Hadker, Nandini; Garg, Suchita; Costanzo, Cory; van der Helm, Wim; Creeden, James
2013-05-01
To quantify the financial impact of adding a novel serum test to the current diagnostic toolkit for preeclampsia (PE) detection in Germany. A decision-analytic model was created to quantify the economic impact of adding a recently developed novel diagnostic test for PE (Roche Diagnostics, Rotkreuz, Switzerland) to current diagnostic practice in Germany. The model simulated a cohort of 1000 pregnant patients receiving obstetric care and quantified the budget impact of adding the novel test to current German PE detection and management practices. The model estimates that the costs associated with managing a typical pregnancy in Germany are €941 when the novel test is used versus €1579 with standard practice. This represents savings of €637 per pregnant woman, even when the test is used as a supplementary diagnostic tool. The savings are attributed to the novel test's ability to better classify patients relative to current practice, specifically, its ability to reduce false negatives by 67% and false positives by 71%. The novel PE test has the potential to provide substantial cost savings to German healthcare payers, even when used as an addition to standard practice. Better classification of patients at risk for developing PE and declassification of those that are not compared to current practice leads to economic savings for the healthcare system. Furthermore, by reducing the rates of false-positive and false-negative classification relative to current standard of care, the test helps better target healthcare spending and lowers overall costs associated with PE care.
Caciagli, P; Verderio, A
2003-06-30
Several aspects of enzyme-linked immunosorbent assay (ELISA) procedures and data analysis have been examined in an attempt to find a rapid and reliable method for discriminating between 'positive' and 'negative' results when testing a large number of samples. A layout of ELISA plates was designed to reduce uncontrolled variation and to optimize the number of negative and positive controls. A transformation using the fourth root (A(1/4)) of the optical density readings corrected for the blank (A) stabilized the variance of most ELISA data examined. Transformed A values were used to calculate the true limits, at a set protection level, for false positive (C) and false negative (D). Methods are discussed to reduce the number of undifferentiated samples, i.e. the samples with response falling between C and D. The whole procedure was set up for use with an electronic spreadsheet. With the addition of few instructions of the type 'if em leader then em leader else' in the spreadsheet, the ELISA results were obtained in the simple trichotomous form 'negative/undefined/positive'. This allowed rapid analysis of more than 1100 maize samples testing for the presence of seven aphid-borne viruses-in fact almost 8000 ELISA samples.
Optimization and validation of CEDIA drugs of abuse immunoassay tests in serum on Hitachi 912.
Kirschbaum, Katrin M; Musshoff, Frank; Schmithausen, Ricarda; Stockhausen, Sarah; Madea, Burkhard
2011-10-10
Due to sensitive limits of detection of chromatographic methods and low limit values regarding the screening of drugs under the terms of impairment in safe driving (§ 24a StVG, Street Traffic Law in Germany), preliminary immunoassay (IA) tests should be able to detect also low concentrations of legal and illegal drugs in serum in forensic cases. False-negatives should be avoided, the rate of false-positive samples should be low due to cost and time. An optimization of IA cutoff values and a validation of the assay is required for each laboratory. In a retrospective study results for serum samples containing amphetamine, methylenedioxy derivatives, cannabinoids, benzodiazepines, cocaine (metabolites), methadone and opiates obtained with CEDIA drugs of abuse reagents on a Hitachi 912 autoanalyzer were compared with quantitative results of chromatographic methods (gas or liquid chromatography coupled with mass spectrometry (GC/MS or LC/MS)). Firstly sensitivity, specificity, positive and negative predictive values and overall misclassification rates were evaluated by contingency tables and compared to ROC-analyses and Youden-Indices. Secondly ideal cutoffs were statistically calculated on the basis of sensitivity and specificity as decisive statistical criteria with focus on a high sensitivity (low rates of false-negatives), i.e. using the Youden-Index. Immunoassay (IA) and confirmatory results were available for 3014 blood samples. Sensitivity was 90% or more for nearly all analytes: amphetamines (IA cutoff 9.5 ng/ml), methylenedioxy derivatives (IA cutoff 5.5 ng/ml), cannabinoids (IA cutoff 14.5 ng/ml), benzodiazepines (IA cutoff >0 ng/ml). Test of opiates showed a sensitivity of 86% for a IA cutoff value of >0 ng/ml. Values for specificity ranged between 33% (methadone, IA cutoff 10 ng/ml) and 90% (cocaine, IA cutoff 20 ng/ml). Lower cutoff values as recommended by ROC analyses were chosen for most tests to decrease the rate of false-negatives. Analyses enabled the definition of cutoff values with good values for sensitivity. Small rates of false-positives can be accepted in forensic cases. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Ranadive, Nikhil; Kunene, Simon; Darteh, Sarah; Ntshalintshali, Nyasatu; Nhlabathi, Nomcebo; Dlamini, Nomcebo; Chitundu, Stanley; Saini, Manik; Murphy, Maxwell; Soble, Adam; Schwartz, Alanna; Greenhouse, Bryan
2017-01-01
Abstract Background. The performance of Plasmodium falciparum–specific histidine-rich protein 2–based rapid diagnostic tests (RDTs) to evaluate suspected malaria in low-endemicity settings has not been well characterized. Methods. Using dried blood spot samples from patients with suspected malaria at 37 health facilities from 2012 to 2014 in the low-endemicity country of Swaziland, we investigated the diagnostic accuracy of histidine-rich protein 2–based RDTs using qualitative polymerase chain reaction (PCR) (nested PCR targeting the cytochrome b gene) and quantitative PCR as reference standards. To explore reasons for false-negative and/or false-positive results, we used pfhrp2/3-specific PCR and logistic regression analyses of potentially associated epidemiological factors. Results. From 1353 patients, 93.0% of RDT-positive (n = 185) and 31.2% of RDT-negative samples (n = 340) were available and selected for testing. Compared with nested PCR, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of RDTs were 51.7%, 94.1%, 67.3%, and 89.1%, respectively. After exclusion of samples with parasite densities <100/μL, which accounted for 75.7% of false-negative results and 33.3% of PCR-detectable infections, the sensitivity, specificity, PPV, and NPV were 78.8%, 93.7%, 62.3%, and 97.1%. Deletions of pfhrp2 were not detected. False-positivity was more likely during the second year and was not associated with demographics, recent malaria, health facility testing characteristics, or potential DNA degradation. Conclusions. In the low-transmission setting of Swaziland, we demonstrated low sensitivity of RDT for malaria diagnosis, owing to an unexpectedly high proportion of low-density infection among symptomatic subjects. The PPV was also low, requiring further investigation. A more accurate point-of-care diagnostic may be needed to support malaria elimination efforts. PMID:28369268
Ranadive, Nikhil; Kunene, Simon; Darteh, Sarah; Ntshalintshali, Nyasatu; Nhlabathi, Nomcebo; Dlamini, Nomcebo; Chitundu, Stanley; Saini, Manik; Murphy, Maxwell; Soble, Adam; Schwartz, Alanna; Greenhouse, Bryan; Hsiang, Michelle S
2017-05-01
The performance of Plasmodium falciparum-specific histidine-rich protein 2-based rapid diagnostic tests (RDTs) to evaluate suspected malaria in low-endemicity settings has not been well characterized. Using dried blood spot samples from patients with suspected malaria at 37 health facilities from 2012 to 2014 in the low-endemicity country of Swaziland, we investigated the diagnostic accuracy of histidine-rich protein 2-based RDTs using qualitative polymerase chain reaction (PCR) (nested PCR targeting the cytochrome b gene) and quantitative PCR as reference standards. To explore reasons for false-negative and/or false-positive results, we used pfhrp2/3-specific PCR and logistic regression analyses of potentially associated epidemiological factors. From 1353 patients, 93.0% of RDT-positive (n = 185) and 31.2% of RDT-negative samples (n = 340) were available and selected for testing. Compared with nested PCR, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of RDTs were 51.7%, 94.1%, 67.3%, and 89.1%, respectively. After exclusion of samples with parasite densities <100/μL, which accounted for 75.7% of false-negative results and 33.3% of PCR-detectable infections, the sensitivity, specificity, PPV, and NPV were 78.8%, 93.7%, 62.3%, and 97.1%. Deletions of pfhrp2 were not detected. False-positivity was more likely during the second year and was not associated with demographics, recent malaria, health facility testing characteristics, or potential DNA degradation. In the low-transmission setting of Swaziland, we demonstrated low sensitivity of RDT for malaria diagnosis, owing to an unexpectedly high proportion of low-density infection among symptomatic subjects. The PPV was also low, requiring further investigation. A more accurate point-of-care diagnostic may be needed to support malaria elimination efforts. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.
Use of General-purpose Negation Detection to Augment Concept Indexing of Medical Documents
Mutalik, Pradeep G.; Deshpande, Aniruddha; Nadkarni, Prakash M.
2001-01-01
Objectives: To test the hypothesis that most instances of negated concepts in dictated medical documents can be detected by a strategy that relies on tools developed for the parsing of formal (computer) languages—specifically, a lexical scanner (“lexer”) that uses regular expressions to generate a finite state machine, and a parser that relies on a restricted subset of context-free grammars, known as LALR(1) grammars. Methods: A diverse training set of 40 medical documents from a variety of specialties was manually inspected and used to develop a program (Negfinder) that contained rules to recognize a large set of negated patterns occurring in the text. Negfinder's lexer and parser were developed using tools normally used to generate programming language compilers. The input to Negfinder consisted of medical narrative that was preprocessed to recognize UMLS concepts: the text of a recognized concept had been replaced with a coded representation that included its UMLS concept ID. The program generated an index with one entry per instance of a concept in the document, where the presence or absence of negation of that concept was recorded. This information was used to mark up the text of each document by color-coding it to make it easier to inspect. The parser was then evaluated in two ways: 1) a test set of 60 documents (30 discharge summaries, 30 surgical notes) marked-up by Negfinder was inspected visually to quantify false-positive and false-negative results; and 2) a different test set of 10 documents was independently examined for negatives by a human observer and by Negfinder, and the results were compared. Results: In the first evaluation using marked-up documents, 8,358 instances of UMLS concepts were detected in the 60 documents, of which 544 were negations detected by the program and verified by human observation (true-positive results, or TPs). Thirteen instances were wrongly flagged as negated (false-positive results, or FPs), and the program missed 27 instances of negation (false-negative results, or FNs), yielding a sensitivity of 95.3 percent and a specificity of 97.7 percent. In the second evaluation using independent negation detection, 1,869 concepts were detected in 10 documents, with 135 TPs, 12 FPs, and 6 FNs, yielding a sensitivity of 95.7 percent and a specificity of 91.8 percent. One of the words “no,” “denies/denied,” “not,” or “without” was present in 92.5 percent of all negations. Conclusions: Negation of most concepts in medical narrative can be reliably detected by a simple strategy. The reliability of detection depends on several factors, the most important being the accuracy of concept matching. PMID:11687566
Diagnosis of canine hypothyroidism. Perspectives from a testing laboratory.
Kemppainen, R J; Behrend, E N
2001-09-01
The most common sample received by our endocrine testing laboratory is submitted for the diagnosis of hypothyroidism in a dog. The current tests most frequently employed in our laboratory for thyroid evaluation in dogs are total T4, free T4 by dialysis, and canine TSH measurement. Each test has strengths and weaknesses and suffers from the possibility of both false positive and false negative results. This article provides a working description of each test and an approach to interpretation of results. Other tests that are less commonly used are also discussed. Examples of interpretation of test results in individual hypothyroid-suspect dogs are presented for illustration.
ERIC Educational Resources Information Center
Frederick, Richard I.; Bowden, Stephen C.
2009-01-01
Common rates employed in classificatory testing are the true positive rate (TPR), false positive rate (FPR), positive predictive power (PPP), and negative predictive power (NPP). FPR and TPR are estimated from research samples representing populations to be distinguished by classificatory testing. PPP and NPP are used by clinicians to classify…
Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L
2018-03-01
There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.
Theron, Grant; Venter, Rouxjeane; Smith, Liezel; Esmail, Aliasgar; Randall, Philippa; Sood, Vishesh; Oelfese, Suzette; Calligaro, Greg; Warren, Robin; Dheda, Keertan
2018-03-01
Globally, Xpert MTB/RIF (Xpert) is the most widely used PCR test for the diagnosis of tuberculosis (TB). Positive results in previously treated patients, which are due to old DNA or active disease, are a diagnostic dilemma. We prospectively retested sputum from 238 patients, irrespective of current symptoms, who were previously diagnosed to be Xpert positive and treated successfully. Patients who retested as Xpert positive and culture negative were exhaustively investigated (repeat culture, chest radiography, bronchoscopy with bronchoalveolar lavage, long-term clinical follow-up). We evaluated whether the duration since previous treatment completion, mycobacterial burden (the Xpert cycle threshold [ C T ] value), and reclassification of Xpert-positive results with a very low semiquantitation level to Xpert-negative results reduced the rate of false positivity. A total of 229/238 (96%) of patients were culture negative. Sixteen of 229 (7%) were Xpert positive a median of 11 months (interquartile range, 5 to 19 months) after treatment completion. The specificity was 93% (95% confidence interval [CI], 89 to 96%). Nine of 15 (40%) Xpert-positive, culture-negative patients reverted to Xpert negative after 2 to 3 months (1 patient declined further participation). Patients with false-positive Xpert results had a lower mycobacterial burden than patients with true-positive Xpert results ( C T , 28.7 [95% CI, 27.2 to 30.4] versus 17.6 [95% CI, 16.9 to 18.2]; P < 0.001), an increased likelihood of a chest radiograph not compatible with active TB (5/15 patients versus 0/5 patients; P = 0.026), and less-viscous sputum (15/16 patients versus 2/5 patients whose sputum was graded as mucoid or less; P = 0.038). All patients who initially retested as Xpert positive and culture negative ("Xpert false positive") were clinically well without treatment after follow-up. The duration since the previous treatment poorly predicted false-positive results (a duration of ≤2 years identified only 66% of patients with false-positive results). Reclassifying Xpert-positive results with a very low semiquantitation level to Xpert negative improved the specificity (+3% [95% CI, +2 to +5%]) but reduced the sensitivity (-10% [95% CI, -4 to -15%]). Patients with previous TB retested with Xpert can have false-positive results and thus not require treatment. These data inform clinical practice by highlighting the challenges in interpreting Xpert-positive results, underscore the need for culture, and have implications for next-generation ultrasensitive tests. Copyright © 2018 American Society for Microbiology.
Validation of a hospital-laboratory workstation for immunohematologic methods.
Schoenfeld, Helge; Pretzel, Karin J; von Heymann, Christian; Neuner, Bruno; Kalus, Ulrich; Kiesewetter, Holger; Pruss, Axel
2010-01-01
The FREELYS Nano system (Diagast) is a manual workstation for ABO/D grouping, Rh phenotyping, K typing, and antibody screening (ABS) for immunoglobulin G (IgG) antibodies only and works with the erythrocyte-magnetized technology (EMT). The principle of EMT is based on magnetization of red blood cells and avoids centrifugation and washing steps. A total of 304 samples were tested with our routine blood bank methods, 100 samples for ABO/D grouping, 196 samples (100 at first evaluation, 96 at second evaluation) for Rh phenotyping and K typing (PK7200, Olympus), and 108 samples for ABS (DiaMed). All samples were tested in parallel with the FREELYS Nano. We found a 100% concordance between the observed (FREELYS Nano) and the expected (Olympus PK7200) results for ABO/D grouping in all 100 samples. For Rh phenotyping and K tests, in 24 of 100 samples false-positive reactions were observed in the first evaluation by the FREELYS Nano. After changing the test kit batch for Rh phenotyping by the manufacturer, a complete concordance in Rh phenotyping and K tests was observed in a second evaluation. For ABS, the FREELYS Nano showed in 4 of 108 samples (3.7%) false-negative reactions for IgG antibodies (two anti-K, one anti-E, one anti-C(w)), and one (0.9%) false-positive reaction. The FREELYS Nano is reliably suited to ABO/D grouping, Rh phenotyping, and K testing. The rate of false-negative reactions for IgG antibodies should be reduced.
Hardie, Diana Ruth; Korsman, Stephen N; Hsiao, Nei-Yuan; Morobadi, Molefi Daniel; Vawda, Sabeehah; Goedhals, Dominique
2017-01-01
In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector laboratories, the performance of two automated platforms was compared in a clinical pathology setting, firstly on routine diagnostic specimens and secondly on known sero-negative samples. Firstly, 1181 routine diagnostic specimens were sequentially tested on Siemens and Roche automated 4th generation platforms. HIV viral load, western blot and follow up testing were used to determine the true status of inconclusive specimens. Subsequently, known HIV seronegative samples from a single donor were repeatedly tested on both platforms and an analyser was tested for surface contamination with HIV positive serum to identify how suspected specimen contamination could be occurring. Serial testing of diagnostic specimens yielded 163 weakly positive or discordant results. Only 3 of 163 were conclusively shown to indicate true HIV infection. Specimen contamination with HIV antibody was suspected, based on the following evidence: the proportion of positive specimens increased on repeated passage through the analysers; viral loads were low or undetectable and western blots negative or indeterminate on problem specimens; screen negative, 2nd test positive specimens tested positive when reanalysed on the screening assay; follow up specimens (where available) were negative. Similarly, an increasing number of known negative specimens became (repeatedly) sero-positive on serial passage through one of the analysers. Internal and external analyser surfaces were contaminated with HIV serum, evidence that sample splashes occur during testing. Due to the extreme sensitivity of these assays, contamination with minute amounts of HIV antibody can cause a negative sample to test positive. Better contamination control measures are needed on analysers used in clinical pathology environments, especially in regions where HIV sero-prevalence is high.
Favaloro, Emmanuel J; McCaughan, Georgia; Mohammed, Soma; Lau, Kun Kan Edwin; Gemmell, Rosalie; Cavanaugh, Lauren; Donikian, Dea; Kondo, Mayuko; Brighton, Timothy; Pasalic, Leonardo
2018-04-17
Heparin induced thrombocytopenia (HIT) is a rare but potentially fatal complication of heparin therapy, which in a proportion of patients causes platelet activation and thrombosis. Initial clinical assessment of the likelihood of HIT is facilitated by laboratory testing to confirm or exclude HIT. This prospective investigation was performed over an 18-month period, and has involved testing of over 300 test samples from over 100 consecutive patients. Clinical assessment by 4T score was supplemented by laboratory tests that comprised both immunological [lateral flow ('STiC'), chemiluminescence (AcuStar; HIT-IgG (PF4-H) ), ELISA (Asserachrom HPIA IgG)] and functional assays [SRA, platelet aggregation using whole blood ('Multiplate') and platelet rich plasma ('LTA')]. We observed both false positive and false negative test findings with most assays. Overall, the whole blood aggregation method provided a reasonable alternative to SRA for identifying functional HIT. STiC, AcuStar and ELISA procedures were fairly comparable in terms of screening for HIT, although STiC and AcuStar both yielded false negatives, albeit also resulting in fewer false positives than ELISA. The 4T score had less utility in our patient cohort than we were expecting, although there was an association with the likelihood of HIT. Nevertheless, we accept that our observations are based on limited test numbers. In conclusion, no single approach (clinical or laboratory) was associated with optimal sensitivity or specificity of HIT exclusion or identification, and thus, a combination of clinical evaluation and laboratory testing will best ensure the accuracy of diagnosis. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Severo, Milton; Silva-Pereira, Fernanda; Ferreira, Maria Amelia
2013-01-01
Several studies have shown that the standard error of measurement (SEM) can be used as an additional “safety net” to reduce the frequency of false-positive or false-negative student grading classifications. Practical examinations in clinical anatomy are often used as diagnostic tests to admit students to course final examinations. The aim of this…
Choi, Hae-Yoon; Kensinger, Elizabeth A; Rajaram, Suparna
2017-09-01
Social transmission of memory and its consequence on collective memory have generated enduring interdisciplinary interest because of their widespread significance in interpersonal, sociocultural, and political arenas. We tested the influence of 3 key factors-emotional salience of information, group structure, and information distribution-on mnemonic transmission, social contagion, and collective memory. Participants individually studied emotionally salient (negative or positive) and nonemotional (neutral) picture-word pairs that were completely shared, partially shared, or unshared within participant triads, and then completed 3 consecutive recalls in 1 of 3 conditions: individual-individual-individual (control), collaborative-collaborative (identical group; insular structure)-individual, and collaborative-collaborative (reconfigured group; diverse structure)-individual. Collaboration enhanced negative memories especially in insular group structure and especially for shared information, and promoted collective forgetting of positive memories. Diverse group structure reduced this negativity effect. Unequally distributed information led to social contagion that creates false memories; diverse structure propagated a greater variety of false memories whereas insular structure promoted confidence in false recognition and false collective memory. A simultaneous assessment of network structure, information distribution, and emotional valence breaks new ground to specify how network structure shapes the spread of negative memories and false memories, and the emergence of collective memory. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Applying a CAD-generated imaging marker to assess short-term breast cancer risk
NASA Astrophysics Data System (ADS)
Mirniaharikandehei, Seyedehnafiseh; Zarafshani, Ali; Heidari, Morteza; Wang, Yunzhi; Aghaei, Faranak; Zheng, Bin
2018-02-01
Although whether using computer-aided detection (CAD) helps improve radiologists' performance in reading and interpreting mammograms is controversy due to higher false-positive detection rates, objective of this study is to investigate and test a new hypothesis that CAD-generated false-positives, in particular, the bilateral summation of false-positives, is a potential imaging marker associated with short-term breast cancer risk. An image dataset involving negative screening mammograms acquired from 1,044 women was retrospectively assembled. Each case involves 4 images of craniocaudal (CC) and mediolateral oblique (MLO) view of the left and right breasts. In the next subsequent mammography screening, 402 cases were positive for cancer detected and 642 remained negative. A CAD scheme was applied to process all "prior" negative mammograms. Some features from CAD scheme were extracted, which include detection seeds, the total number of false-positive regions, an average of detection scores and the sum of detection scores in CC and MLO view images. Then the features computed from two bilateral images of left and right breasts from either CC or MLO view were combined. In order to predict the likelihood of each testing case being positive in the next subsequent screening, two logistic regression models were trained and tested using a leave-one-case-out based cross-validation method. Data analysis demonstrated the maximum prediction accuracy with an area under a ROC curve of AUC=0.65+/-0.017 and the maximum adjusted odds ratio of 4.49 with a 95% confidence interval of [2.95, 6.83]. The results also illustrated an increasing trend in the adjusted odds ratio and risk prediction scores (p<0.01). Thus, the study showed that CAD-generated false-positives might provide a new quantitative imaging marker to help assess short-term breast cancer risk.
Standoff detection of chemical and biological threats using laser-induced breakdown spectroscopy.
Gottfried, Jennifer L; De Lucia, Frank C; Munson, Chase A; Miziolek, Andrzej W
2008-04-01
Laser-induced breakdown spectroscopy (LIBS) is a promising technique for real-time chemical and biological warfare agent detection in the field. We have demonstrated the detection and discrimination of the biological warfare agent surrogates Bacillus subtilis (BG) (2% false negatives, 0% false positives) and ovalbumin (0% false negatives, 1% false positives) at 20 meters using standoff laser-induced breakdown spectroscopy (ST-LIBS) and linear correlation. Unknown interferent samples (not included in the model), samples on different substrates, and mixtures of BG and Arizona road dust have been classified with reasonable success using partial least squares discriminant analysis (PLS-DA). A few of the samples tested such as the soot (not included in the model) and the 25% BG:75% dust mixture resulted in a significant number of false positives or false negatives, respectively. Our preliminary results indicate that while LIBS is able to discriminate biomaterials with similar elemental compositions at standoff distances based on differences in key intensity ratios, further work is needed to reduce the number of false positives/negatives by refining the PLS-DA model to include a sufficient range of material classes and carefully selecting a detection threshold. In addition, we have demonstrated that LIBS can distinguish five different organophosphate nerve agent simulants at 20 meters, despite their similar stoichiometric formulas. Finally, a combined PLS-DA model for chemical, biological, and explosives detection using a single ST-LIBS sensor has been developed in order to demonstrate the potential of standoff LIBS for universal hazardous materials detection.
The diagnostic significance of lactate dehydrogenase isoenzymes in urinary cytology.
Nishikawa, A.; Tanaka, T.; Takeuchi, T.; Fujihiro, S.; Mori, H.
1991-01-01
Lactate dehydrogenase (LDH) isoenzyme distribution was examined in 106 urine samples being tested cytologically for evidence of bladder cancer; the samples were selected to have less than 20 leucocytes and erythrocytes per high power field and the LDH pattern determined by electrophoresis. The Papanicolaou stained-smears showed 68 negative, 17 suspicious and 21 positive. The LDH M-fraction of the urinary supernatant in cytologically positive cases was significantly greater than in negative cases, although the latter included a few false negative samples. Some of the false negatives gave positive results for the LDH M-fraction; these results suggest that the determination of LDH isoenzymes in the urine is useful in diagnosing urinary tract cancers, including early stage, and for follow-up of patients with bladder cancers after surgical resection. PMID:2039708
Experimental investigation of false positive errors in auditory species occurrence surveys
Miller, David A.W.; Weir, Linda A.; McClintock, Brett T.; Grant, Evan H. Campbell; Bailey, Larissa L.; Simons, Theodore R.
2012-01-01
False positive errors are a significant component of many ecological data sets, which in combination with false negative errors, can lead to severe biases in conclusions about ecological systems. We present results of a field experiment where observers recorded observations for known combinations of electronically broadcast calling anurans under conditions mimicking field surveys to determine species occurrence. Our objectives were to characterize false positive error probabilities for auditory methods based on a large number of observers, to determine if targeted instruction could be used to reduce false positive error rates, and to establish useful predictors of among-observer and among-species differences in error rates. We recruited 31 observers, ranging in abilities from novice to expert, that recorded detections for 12 species during 180 calling trials (66,960 total observations). All observers made multiple false positive errors and on average 8.1% of recorded detections in the experiment were false positive errors. Additional instruction had only minor effects on error rates. After instruction, false positive error probabilities decreased by 16% for treatment individuals compared to controls with broad confidence interval overlap of 0 (95% CI: -46 to 30%). This coincided with an increase in false negative errors due to the treatment (26%; -3 to 61%). Differences among observers in false positive and in false negative error rates were best predicted by scores from an online test and a self-assessment of observer ability completed prior to the field experiment. In contrast, years of experience conducting call surveys was a weak predictor of error rates. False positive errors were also more common for species that were played more frequently, but were not related to the dominant spectral frequency of the call. Our results corroborate other work that demonstrates false positives are a significant component of species occurrence data collected by auditory methods. Instructing observers to only report detections they are completely certain are correct is not sufficient to eliminate errors. As a result, analytical methods that account for false positive errors will be needed, and independent testing of observer ability is a useful predictor for among-observer variation in observation error rates.
Establishing a sample-to cut-off ratio for lab-diagnosis of hepatitis C virus in Indian context.
Tiwari, Aseem K; Pandey, Prashant K; Negi, Avinash; Bagga, Ruchika; Shanker, Ajay; Baveja, Usha; Vimarsh, Raina; Bhargava, Richa; Dara, Ravi C; Rawat, Ganesh
2015-01-01
Lab-diagnosis of hepatitis C virus (HCV) is based on detecting specific antibodies by enzyme immuno-assay (EIA) or chemiluminescence immuno-assay (CIA). Center for Disease Control reported that signal-to-cut-off (s/co) ratios in anti-HCV antibody tests like EIA/CIA can be used to predict the probable result of supplemental test; above a certain s/co value it is most likely to be true-HCV positive result and below that certain s/co it is most likely to be false-positive result. A prospective study was undertaken in patients in tertiary care setting for establishing this "certain" s/co value. The study was carried out in consecutive patients requiring HCV testing for screening/diagnosis and medical management. These samples were tested for anti-HCV on CIA (VITROS(®) Anti-HCV assay, Ortho-Clinical Diagnostics, New Jersey) for calculating s/co value. The supplemental nucleic acid test used was polymerase chain reaction (PCR) (Abbott). PCR test results were used to define true negatives, false negatives, true positives, and false positives. Performance of different putative s/co ratios versus PCR was measured using sensitivity, specificity, positive predictive value and negative predictive value and most appropriate s/co was considered on basis of highest specificity at sensitivity of at least 95%. An s/co ratio of ≥6 worked out to be over 95% sensitive and almost 92% specific in 438 consecutive patient samples tested. The s/co ratio of six can be used for lab-diagnosis of HCV infection; those with s/co higher than six can be diagnosed to have HCV infection without any need for supplemental assays.
Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young
2008-08-01
We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.
Accuracy of BRT and Delvotest microbial inhibition tests as affected by composition of ewe's milk.
Althaus, Rafael; Torres, Antonio; Peris, Cristofol; Beltran, M Carmen; Fernandez, Nemesio; Molina, M Pilar
2003-03-01
The presence of drug residues in ewe's milk samples can be determined by microbial assays. The main limitation of these tests is the large number of false-positive results associated with them. False-positive results can be explained by the interaction of certain substances naturally existing in ewe's milk with the growth of the microorganism used in the test. In this study, milk chemical composition (fat, protein, lactose, total solids), somatic cell counts (SCCs), free fatty acid concentrations, and lactoperoxidase system components were determined in order to investigate their influence on the rate of false-positive results for the BRT and Delvotest microbiological inhibitor tests. Milk samples were obtained after morning milking of Manchega ewes at 15, 30, 45, 60, 75, 90, 105, 120, and 135 days after parturition. The animals did not receive any kind of treatment or medicated feed throughout the experiment. The false-positive rates for BRT and Delvotest were 3.75 and 2.4%, respectively. When the logistic regression model was applied, the percentages of total solids for positive samples were significantly different from those for negative samples (16.90 versus 18.42% for BRT, 16.05 versus 18.45% for Delvotest), while the SCC logarithmic transformation was significantly higher for the positive samples than for the negative samples (5.38 versus 5.11 log units for BRT, 5.32 versus 5.11 log units for Delvotest). Moreover, Delvotest-positive samples exhibited thiocyanate concentrations higher than those of Delvotest-negative samples (8.18 mg/liter versus 6.85 mg/liter). Further analyses are needed to confirm the possible presence of antimicrobial residues in this particular type of milk sample.
Human Immunodeficiency Virus (HIV) Testing and False Disclosures in Heterosexual College Students
ERIC Educational Resources Information Center
Marelich, William D.; Clark, Tonya
2004-01-01
The authors assessed factors that motivate individuals to report negative human immunodeficiency virus (HIV) antibody test results, although they had never been tested. In particular, they investigated sexual intimacy motives associated with the needs for affiliation, sex, and dominance as contributing factors for faulty disclosures. Participants…
Ahmed, Ayesha; Ahmed, Sajjad
2004-01-01
The objectives of this study were to compare bronchoalveolar lavage (BAL) cytology and transbronchial biopsy in the diagnosis of carcinoma lung and to determine accuracy of BAL cytology using histopathlologic examination of transbronchial biopsy as gold standard at our center. This study was carried out at Department of Histopathology, Ayub Medical College, Abbottabad, from 1.09.2000 to 28.02.2003. BAL fluid and bronchial biopsy were received and processed simultaneously. Four cytology and a set of histopathology slides were prepared. These were screened and diagnosis recorded. Sensitivity, Specificity, False Positive, False Negative, Positive predictive value and Negative predictive value of BAL cytology were determined using histopathology of transbronchial biopsy as gold standard. We found the sensitivity of BAL cytology to be 93.44% as compared with transbronchial biopsy. The specificity was 100%. There was no false positive while false negative results were 6.55 %. The positive predictive value was 100 %, while the negative predictive value was 75 %. The overall diagnostic efficacy of BAL cytology was 94.52 %. BAL cytology is a highly sensitive and specific test for diagnosis of carcinoma lung. It can be used as a quick and reliable diagnostic method for diagnosis of lung malignancy.
Gillet, Philippe; Mumba Ngoyi, Dieudonné; Lukuka, Albert; Kande, Viktor; Atua, Benjamin; van Griensven, Johan; Muyembe, Jean-Jacques; Jacobs, Jan; Lejon, Veerle
2013-01-01
Background In endemic settings, diagnosis of malaria increasingly relies on the use of rapid diagnostic tests (RDTs). False positivity of such RDTs is poorly documented, although it is especially relevant in those infections that resemble malaria, such as human African trypanosomiasis (HAT). We therefore examined specificity of malaria RDT products among patients infected with Trypanosoma brucei gambiense. Methodology/Principal Findings Blood samples of 117 HAT patients and 117 matched non-HAT controls were prospectively collected in the Democratic Republic of the Congo. Reference malaria diagnosis was based on real-time PCR. Ten commonly used malaria RDT products were assessed including three two-band and seven three-band products, targeting HRP-2, Pf-pLDH and/or pan-pLDH antigens. Rheumatoid factor was determined in PCR negative subjects. Specificity of the 10 malaria RDT products varied between 79.5 and 100% in HAT-negative controls and between 11.3 and 98.8% in HAT patients. For seven RDT products, specificity was significantly lower in HAT patients compared to controls. False positive reactions in HAT were mainly observed for pan-pLDH test lines (specificities between 13.8 and 97.5%), but also occurred frequently for the HRP-2 test line (specificities between 67.9 and 98.8%). The Pf-pLDH test line was not affected by false-positive lines in HAT patients (specificities between 97.5 and 100%). False positivity was not associated to rheumatoid factor, detected in 7.6% of controls and 1.2% of HAT patients. Conclusions/Significance Specificity of some malaria RDT products in HAT was surprisingly low, and constitutes a risk for misdiagnosis of a fatal but treatable infection. Our results show the importance to assess RDT specificity in non-targeted infections when evaluating diagnostic tests. PMID:23638201
Whiley, Harriet
2016-12-24
Legionella is an opportunistic pathogen of public health significance. One of the main sources of Legionella is potable water systems. As a consequence of aging populations there is an increasing demographic considered at high risk for Legionellosis and, as such, a review of the guidelines is required. Worldwide, Legionella has been detected from many potable water sources, suggesting it is ubiquitous in this environment. Previous studies have identified the limitations of the current standard method for Legionella detection and the high possibility of it returning both false negative and false positive results. There is also huge variability in Legionella test results for the same water sample when conducted at different laboratories. However, many guidelines still recommend the testing of water systems. This commentary argues for the removal of routine Legionella monitoring from all water distribution guidelines. This procedure is financially consuming and false negatives may result in managers being over-confident with a system or a control mechanism. Instead, the presence of the pathogen should be assumed and focus spent on managing appropriate control measures and protecting high-risk population groups.
Whiley, Harriet
2016-01-01
Legionella is an opportunistic pathogen of public health significance. One of the main sources of Legionella is potable water systems. As a consequence of aging populations there is an increasing demographic considered at high risk for Legionellosis and, as such, a review of the guidelines is required. Worldwide, Legionella has been detected from many potable water sources, suggesting it is ubiquitous in this environment. Previous studies have identified the limitations of the current standard method for Legionella detection and the high possibility of it returning both false negative and false positive results. There is also huge variability in Legionella test results for the same water sample when conducted at different laboratories. However, many guidelines still recommend the testing of water systems. This commentary argues for the removal of routine Legionella monitoring from all water distribution guidelines. This procedure is financially consuming and false negatives may result in managers being over-confident with a system or a control mechanism. Instead, the presence of the pathogen should be assumed and focus spent on managing appropriate control measures and protecting high-risk population groups. PMID:28029126
49 CFR 40.273 - What is the effect of a cancelled alcohol test?
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 1 2011-10-01 2011-10-01 false What is the effect of a cancelled alcohol test? 40... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Alcohol Testing § 40.273 What is the effect of a cancelled alcohol test? (a) A cancelled alcohol test is neither positive nor negative. (1) As...
49 CFR 40.273 - What is the effect of a cancelled alcohol test?
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 1 2012-10-01 2012-10-01 false What is the effect of a cancelled alcohol test? 40... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Alcohol Testing § 40.273 What is the effect of a cancelled alcohol test? (a) A cancelled alcohol test is neither positive nor negative. (1) As...
49 CFR 40.273 - What is the effect of a cancelled alcohol test?
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 1 2014-10-01 2014-10-01 false What is the effect of a cancelled alcohol test? 40... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Alcohol Testing § 40.273 What is the effect of a cancelled alcohol test? (a) A cancelled alcohol test is neither positive nor negative. (1) As...
49 CFR 40.273 - What is the effect of a cancelled alcohol test?
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 1 2013-10-01 2013-10-01 false What is the effect of a cancelled alcohol test? 40... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Alcohol Testing § 40.273 What is the effect of a cancelled alcohol test? (a) A cancelled alcohol test is neither positive nor negative. (1) As...
49 CFR 40.207 - What is the effect of a cancelled drug test?
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 1 2012-10-01 2012-10-01 false What is the effect of a cancelled drug test? 40... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests § 40.207 What is the effect of a cancelled drug test? (a) A cancelled drug test is neither positive nor negative. (1) As an...
49 CFR 40.207 - What is the effect of a cancelled drug test?
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 1 2011-10-01 2011-10-01 false What is the effect of a cancelled drug test? 40... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests § 40.207 What is the effect of a cancelled drug test? (a) A cancelled drug test is neither positive nor negative. (1) As an...
49 CFR 40.207 - What is the effect of a cancelled drug test?
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false What is the effect of a cancelled drug test? 40... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests § 40.207 What is the effect of a cancelled drug test? (a) A cancelled drug test is neither positive nor negative. (1) As an...
49 CFR 40.207 - What is the effect of a cancelled drug test?
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 1 2014-10-01 2014-10-01 false What is the effect of a cancelled drug test? 40... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests § 40.207 What is the effect of a cancelled drug test? (a) A cancelled drug test is neither positive nor negative. (1) As an...
49 CFR 40.207 - What is the effect of a cancelled drug test?
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 1 2013-10-01 2013-10-01 false What is the effect of a cancelled drug test? 40... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Problems in Drug Tests § 40.207 What is the effect of a cancelled drug test? (a) A cancelled drug test is neither positive nor negative. (1) As an...
Issa, Amalia M; Tufail, Waqas; Atehortua, Nelson; McKeever, John
2013-05-01
Molecular diagnostics are increasingly being used to help guide decision-making for personalized medical treatment of breast and colorectal cancer patients. The main aim of this study was to better understand and determine breast and colorectal cancer patients' decision-making strategies and the trade-offs they make in deciding about characteristics of molecular genomic diagnostics for breast and colorectal cancer. We surveyed a nationally representative sample of 300 breast and colorectal cancer patients using a previously developed web-administered instrument. Eligibility criteria included patients aged 18 years and older with either breast or colorectal cancer. We explored several attributes and attribute levels of molecular genomic diagnostics in 20 scenarios. Our analysis revealed that both breast and colorectal cancer patients weighted the capability of molecular genomic diagnostics to determine the probability of treatment efficacy as being of greater importance than information provided to detect adverse events. The probability of either false-positive or -negative results was ranked highly as a potential barrier by both breast and colorectal patients. However, 78.6% of breast cancer patients ranked the possibility of a 'false-negative test result leading to undertreatment' higher than the 'chance of a false positive, which may lead to overtreatment' (68%). This finding contrasted with the views of colorectal cancer patients who ranked the chance of a false positive as being of greater concern than a false negative (72.8 vs 63%). Overall, cancer patients exhibited a high willingness to accept and pay for genomic diagnostic tests, especially among breast cancer patients. Cancer patients seek a test accuracy rate of 90% or higher. Breast and colorectal cancer patients' decisions about genomic diagnostics are influenced more by the probability of being cured than by avoiding potential severe adverse events. This study provides insights into the relative weight that breast and colorectal cancer patients place on various aspects of molecular genomic diagnostics, and the trade-offs they are willing to make among attributes of such tests.
Bandyopadhyay, Sanghamitra; Mitra, Ramkrishna
2009-10-15
Prediction of microRNA (miRNA) target mRNAs using machine learning approaches is an important area of research. However, most of the methods suffer from either high false positive or false negative rates. One reason for this is the marked deficiency of negative examples or miRNA non-target pairs. Systematic identification of non-target mRNAs is still not addressed properly, and therefore, current machine learning approaches are compelled to rely on artificially generated negative examples for training. In this article, we have identified approximately 300 tissue-specific negative examples using a novel approach that involves expression profiling of both miRNAs and mRNAs, miRNA-mRNA structural interactions and seed-site conservation. The newly generated negative examples are validated with pSILAC dataset, which elucidate the fact that the identified non-targets are indeed non-targets.These high-throughput tissue-specific negative examples and a set of experimentally verified positive examples are then used to build a system called TargetMiner, a support vector machine (SVM)-based classifier. In addition to assessing the prediction accuracy on cross-validation experiments, TargetMiner has been validated with a completely independent experimental test dataset. Our method outperforms 10 existing target prediction algorithms and provides a good balance between sensitivity and specificity that is not reflected in the existing methods. We achieve a significantly higher sensitivity and specificity of 69% and 67.8% based on a pool of 90 feature set and 76.5% and 66.1% using a set of 30 selected feature set on the completely independent test dataset. In order to establish the effectiveness of the systematically generated negative examples, the SVM is trained using a different set of negative data generated using the method in Yousef et al. A significantly higher false positive rate (70.6%) is observed when tested on the independent set, while all other factors are kept the same. Again, when an existing method (NBmiRTar) is executed with the our proposed negative data, we observe an improvement in its performance. These clearly establish the effectiveness of the proposed approach of selecting the negative examples systematically. TargetMiner is now available as an online tool at www.isical.ac.in/ approximately bioinfo_miu
21 CFR 640.5 - Testing the blood.
Code of Federal Regulations, 2010 CFR
2010-04-01
... be negative to a serological test for syphilis. (b) Determination of blood group. Each container of Whole Blood shall be classified as to ABO blood group. At least two blood group tests shall be made and... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Testing the blood. 640.5 Section 640.5 Food and...
Hakim, R; Black, P M
1998-01-01
After the initial description of normal pressure hydrocephalus (NPH) and its clinical triad, there has been a continuous interest from clinicians and researchers to set different diagnostic criteria that would make the selection of candidates for shunt surgery easier and more precise. A preliminary group of 12 patients was given a diagnosis of idiopathic normal pressure hydrocephalus by clinical and radiologic criteria. Each patient underwent two different tests: a magnetic resonance imaging-cerebrospinal fluid (MRI-CSF) flow study and a lumbo-ventricular perfusion test. The purpose was to compare the correlation of the results obtained with these tests and the clinical results obtained after CSF diversion. Eleven patients were given shunts and one was managed with lumbar punctures. One year after treatment, 10 of the 12 patients had improved with good results. The MRI-CSF flow studies were reliable in six patients; there were five false negatives and one false positive. The lumbo-ventricular perfusion test showed reliability in nine patients; there were two false negatives and one false positive. In only three patients were the results of both of these tests in accordance with the outcome. Even though there are few patients in this study so far, the data suggests that at the present time the most predictive guides for the diagnosis of NPH and its outcome after shunting are the clinical criteria and the radiological findings in computed tomography (CT) and/or MRI rather than lumbo-ventricular perfusion and CSF flow studies.
Landry, Marie L.; Eid, Tore; Bannykh, Serguei; Major, Eugene
2009-01-01
Genome amplification methods such as polymerase chain reaction (PCR) have revolutionized our ability to detect viruses in spinal fluids of patients with neurologic diseases. It is not as well appreciated among clinicians that PCR protocols, quality assurance, and technical expertise vary significantly among laboratories. In a multi-laboratory blinded study of herpes simplex virus PCR, the most widely used and best validated CSF PCR assay, low-level positives were often missed and false positives were not uncommon [Schloss L, van Loon AM, Cinque P, Cleator G, Echevarria JM, Falk KI, et al. An international external quality assessment of nucleic acid amplification of herpes simplex virus. J Clin Virol 2003;28(2):175–85]. In addition, genome variability and mutations, which are increasingly recognized for a number of different viruses, can lead to falsely low or negative results. Both clinicians and laboratories must recognize the limitations of PCR, since misleading results may have serious consequences. We present here a case of a rapidly progressive, fatal neurologic illness in a young mother, whose CSF JCV DNA PCR at a reference laboratory was falsely negative. Ultimately, brain biopsy established the diagnosis of progressive multifocal leukoencephalopathy (PML). Repeat PCR testing of the same CSF targeting a different region of the genome yielded a high positive result. PMID:18701345
Roberts, David W; Schultz, Terry W; Api, Anne Marie
2016-10-01
The Local Lymph Node Assay (LLNA) is the gold standard regulatory toxicology test for skin sensitisation along with the guinea pig maximisation test (GPMT). Compared with the GPMT, LLNA uses fewer animals, it is quantitative, and it gives a numerical prediction of potency. However several concerns have been raised with this assay, mainly related to false positives and false negatives. Over the years, many authors, including the developers of the assay, have presented cases where there have been discrepancies between the GMPT and LLNA results. Several theories have been put forward for these discrepancies, the main one being the "over-sensitivity" of the GPMT. This paper analyses the data from a systematic study, published in three papers from 2008 to 2011, covering several classes of chemicals, in particular unsaturated fatty acids, sugar surfactants and ethoxylated alcohols, with many cases of chemicals testing positive in the LLNA being negative in the GPMT. Based on consideration of reaction chemistry and structural alerts, it is concluded that these discrepancies are not LLNA false positives, but can be rationalised in terms of the different protocols of the assays. Copyright © 2016 Elsevier Inc. All rights reserved.
75 FR 28619 - Meeting of the Advisory Committee on Blood Safety and Availability
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-21
... began prior to the availability of tests for HIV in early 1985. The deferral has existed in its current form since September 1985. This and other related FDA policies are designed to address the major... screened using highly sensitive tests, screening tests can be falsely negative during the ``window period...
Chacón, Lucía; Mateos, María Luisa; Holguín, África
2017-07-01
Despite the high specificity of fourth-generation enzyme immunoassays (4th-gen-EIA) for screening during HIV diagnosis, their positive predictive value is low in populations with low HIV prevalence. Thus, screening should be optimized to reduce false positive results. The influence of sample cutoff (S/CO) values by a 4th-gen-EIA with the false positive rate during the routine HIV diagnosis in a low HIV prevalence population was evaluated. A total of 30,201 sera were tested for HIV diagnosis using Abbott Architect ® HIV-Ag/Ab-Combo 4th-gen-EIA at a hospital in Spain during 17 months. Architect S/CO values were recorded, comparing the HIV-1 positive results following Architect interpretation (S/CO≥1) with the final HIV-1 diagnosis by confirmatory tests (line immunoassay, LIA and/or nucleic acid test, NAT). ROC curve was also performed. Among the 30,201 HIV performed tests, 256 (0.85%) were positive according to Architect interpretation (S/CO≥1) but only 229 (0.76%) were definitively HIV-1 positive after LIA and/or NAT. Thus, 27 (10.5%) of 256 samples with S/CO≥1 by Architect were false positive diagnose. The false positive rate decreased when the S/CO ratio increased. All 19 samples with S/CO ≤10 were false positives and all 220 with S/CO>50 true HIV-positives. The optimal S/CO cutoff value provided by ROC curves was 32.7. No false negative results were found. We show that very low S/CO values during HIV-1 screening using Architect can result HIV negative after confirmation by LIA and NAT. The false positive rate is reduced when S/CO increases. Copyright © 2017 Elsevier B.V. All rights reserved.
Oxybuprocaine induces a false-positive response in immunochromatographic SAS Adeno Test.
Hoshino, Takeshi; Takanashi, Taiji; Okada, Morio; Uchida, Sunao
2002-04-01
To investigate whether a solution of oxybuprocaine hydrochloride, 0.4%, results in a false-positive response in an immunochromatographic SAS Adeno Test. Experimental study. Physiologic saline and 2% lidocaine. Each chemical (100 microl) was diluted in a transport medium. Five drops (200 microl) of the resultant solution were dispensed into the round sample well of a test device. Fifteen samples were tested in each group. Ten minutes after the start of the test, a colored line in the "specimen" portion of the test membrane was visually read as positive or negative by a masked technician. No positive reaction was observed in the control groups (physiologic saline and lidocaine). A false-positive reaction was observed in six samples (33.3%) in the oxybuprocaine group. The positive rate was significantly higher in the oxybuprocaine group compared with those in control groups (P = 0.0062, Fisher's extract probability test). Oxybuprocaine may induce a false-positive reaction in an immunochromatographic SAS Adeno Test. We recommend the use of lidocaine, instead of oxybuprocaine, for local anesthesia in taking eye swabs from patients with suspected adenovirus infection.
Salter, Robert; Holmes, Steven; Legg, David; Coble, Joel; George, Bruce
2012-02-01
Pork tissue samples that tested positive and negative by the Charm II tetracycline test screening method in the slaughter plant laboratory were tested with the modified AOAC International liquid chromatography tandem mass spectrometry (LC-MS-MS) method 995.09 to determine the predictive value of the screening method at detecting total tetracyclines at 10 μg/kg of tissue, in compliance with Russian import regulations. There were 218 presumptive-positive tetracycline samples of 4,195 randomly tested hogs. Of these screening test positive samples, 83% (182) were positive, >10 μg/kg by LC-MS-MS; 12.8% (28) were false violative, greater than limit of detection (LOD) but <10 μg/kg; and 4.2% (8) were not detected at the LC-MS-MS LOD. The 36 false-violative and not-detected samples represent 1% of the total samples screened. Twenty-seven of 30 randomly selected tetracycline screening negative samples tested below the LC-MS-MS LOD, and 3 samples tested <3 μg/kg chlortetracycline. Results indicate that the Charm II tetracycline test is effective at predicting hogs containing >10 μg/kg total tetracyclines in compliance with Russian import regulations.
Saniee, Parastoo; Shahreza, Somayeh; Siavoshi, Farideh
2016-04-01
Proton-pump inhibitor (PPI) consumption does lead to false-negative results of Helicobacter pylori diagnostic tests such as biopsy culture and rapid urease test (RUT). Helicobacter pylori isolates from 112 dyspeptic patients with (56.5%) or without (43.5%) PPI consumption were recruited for examining the negative effects of omeprazole (OMP), lansoprazole (LPZ), and pantoprazole (PAN) on H. pylori viability, morphology, and urease, in vitro. The effect of a sublethal concentration of OMP on bacterial features and their recovery after removal of OMP was also assessed. Of 112 culture-positive gastric biopsies, 87.5% were RUT positive and 12.5% RUT negative. There was a significant correlation between negative RUT results and PPI consumption (p < .05). OMP (minimum inhibitory concentration, MIC 32 μg/mL) and LPZ (MIC 8 μg/mL) inhibited the growth of 78.6% of H. pylori isolates. OMP and LPZ inhibited urease of 90.3% of isolates between 0 and 40 minutes and 54.4% between 20 and 40 minutes, respectively. PAN did not inhibit H. pylori growth and urease. Three 3-day (9 days) consecutive subcultures of H. pylori on brucella blood agar (BBA) supplemented with OMP resulted in reduced bacterial viability (1+), compared with control (4+), change of spiral morphology to coccoid, and reduction in pink color intensity in urea agar. Bacterial growth (1+), morphology, and urease test did not improve after the first 3-day and second 3-day (6 days) subcultures on BBA. However, relative recovery occurred after the third 3-day (9 days) subculture and complete recovery was observed after the fourth 3-day (12 days) subculture, as confluent growth (4+), 100% spiral cells, and strong urease test. Proton-pump Inhibitors exert transient negative effects on H. pylori viability, morphology, and urease test. Accordingly, cessation of PPI consumption at least 12 days before endoscopy could help avoiding false-negative results of H. pylori diagnostic tests. © 2015 John Wiley & Sons Ltd.
Makkar, Steve R; Grisham, Jessica R
2013-03-01
Current social phobia models (e.g., Clark & Wells, 1995; Leary & Kowalski, 1995) postulate that socially anxious individuals negatively appraise their anxiety sensations (e.g., sweating, heart racing, blushing) as evidence of poor social performance, and thus fear these anxiety symptoms will be noticed and judged negatively by others. Consequently, they become self-focused and hypervigilant of these sensations and use them to judge how they appear to others. To test this model, high (N=41) and low (N=38) socially anxious participants were shown false physiological feedback regarding an increase or decrease in heart rate prior to and during an impromptu speech task. Relative to participants who observed a false heart rate decrease, those in the increase condition reported higher levels of negative affect, more negative performance appraisals, and more frequent negative ruminative thoughts, and these effects were mediated by an increase in self-focused attention. The unhelpful effects of the physiological feedback were not specific to high socially anxious participants. The results have implications for current cognitive models as well as the treatment of social phobia. Copyright © 2012. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, James Christopher; Rennie, John Alan; Toevs, James Waldo
The introduction points out that radiation backgrounds fluctuate across very short distances: factors include geology, soil composition, altitude, building structures, topography, and other manmade structures; and asphalt and concrete can vary significantly over short distances. Brief descriptions are given of the detection system, experimental setup, and background variation measurements. It is concluded that positive and negative gradients can greatly reduce the detection sensitivity of an MDS: negative gradients create opportunities for false negatives (nondetection), and positive gradients create a potentially unacceptable FAR (above 1%); the location of use for mobile detection is important to understand; spectroscopic systems provide more informationmore » for screening out false alarms and may be preferred for mobile use; and mobile monitor testing at LANL accounts for expected variations in the background.« less
Porter, Stephen; Taylor, Kristian; Ten Brinke, Leanne
2008-01-01
Despite a large body of false memory research, little has addressed the potential influence of an event's emotional content on susceptibility to false recollections. The Paradoxical Negative Emotion (PNE) hypothesis predicts that negative emotion generally facilitates memory but also heightens susceptibility to false memories. Participants were asked whether they could recall 20 "widely publicised" public events (half fictitious) ranging in emotional valence, with or without visual cues. Participants recalled a greater number of true negative events (M=3.31/5) than true positive (M=2.61/5) events. Nearly everyone (95%) came to recall at least one false event (M=2.15 false events recalled). Further, more than twice as many participants recalled any false negative (90%) compared to false positive (41.7%) events. Negative events, in general, were associated with more detailed memories and false negative event memories were more detailed than false positive event memories. Higher dissociation scores were associated with false recollections of negative events, specifically.
Emotion and false memory: The context-content paradox.
Bookbinder, S H; Brainerd, C J
2016-12-01
False memories are influenced by a variety of factors, but emotion is a variable of special significance, for theoretical and practical reasons. Interestingly, emotion's effects on false memory depend on whether it is embedded in the content of to-be-remembered events or in our moods, where mood is an aspect of the context in which events are encoded. We sketch the theoretical basis for this content-context dissociation and then review accumulated evidence that content and context effects are indeed different. Paradoxically, we find that in experiments on spontaneous and implanted false memories, negatively valenced content foments distortion, but negatively valenced moods protect against it. In addition, correlational data show that enduring negative natural moods (e.g., depression) foment false memory. Current opponent-process models of false memory, such as fuzzy-trace theory, are able to explain the content-context dissociation: Variations in emotional content primarily affect memory for the gist of events, whereas variations in emotional context primarily affect memory for events' exact verbatim form. Important questions remain about how these effects are modulated by variations in memory tests and in arousal. Promising methods of tackling those questions are outlined, especially designs that separate the gist and verbatim influences of emotion. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Berhane, Araia; Anderson, Karen; Mihreteab, Selam; Gresty, Karryn; Rogier, Eric; Mohamed, Salih; Hagos, Filmon; Embaye, Ghirmay; Chinorumba, Anderson; Zehaie, Assefash; Dowd, Simone; Waters, Norman C.; Gatton, Michelle L.; Udhayakumar, Venkatachalam; Cunningham, Jane
2018-01-01
False-negative results for Plasmodium falciparum histidine-rich protein (HRP) 2–based rapid diagnostic tests (RDTs) are increasing in Eritrea. We investigated HRP gene 2/3 (pfhrp2/pfhrp3) status in 50 infected patients at 2 hospitals. We showed that 80.8% (21/26) of patients at Ghindae Hospital and 41.7% (10/24) at Massawa Hospital were infected with pfhrp2-negative parasites and 92.3% (24/26) of patients at Ghindae Hospital and 70.8% (17/24) at Massawa Hospital were infected with pfhrp3-negative parasites. Parasite densities between pfhrp2-positive and pfhrp2-negative patients were comparable. All pfhrp2-negative samples had no detectable HRP2/3 antigen and showed negative results for HRP2-based RDTs. pfhrp2-negative parasites were genetically less diverse and formed 2 clusters with no close relationships to parasites from Peru. These parasites probably emerged independently by selection in Eritrea. High prevalence of pfhrp2-negative parasites caused a high rate of false-negative results for RDTs. Determining prevalence of pfhrp2-negative parasites is urgently needed in neighboring countries to assist case management policies. PMID:29460730
Berhane, Araia; Anderson, Karen; Mihreteab, Selam; Gresty, Karryn; Rogier, Eric; Mohamed, Salih; Hagos, Filmon; Embaye, Ghirmay; Chinorumba, Anderson; Zehaie, Assefash; Dowd, Simone; Waters, Norman C; Gatton, Michelle L; Udhayakumar, Venkatachalam; Cheng, Qin; Cunningham, Jane
2018-03-01
False-negative results for Plasmodium falciparum histidine-rich protein (HRP) 2-based rapid diagnostic tests (RDTs) are increasing in Eritrea. We investigated HRP gene 2/3 (pfhrp2/pfhrp3) status in 50 infected patients at 2 hospitals. We showed that 80.8% (21/26) of patients at Ghindae Hospital and 41.7% (10/24) at Massawa Hospital were infected with pfhrp2-negative parasites and 92.3% (24/26) of patients at Ghindae Hospital and 70.8% (17/24) at Massawa Hospital were infected with pfhrp3-negative parasites. Parasite densities between pfhrp2-positive and pfhrp2-negative patients were comparable. All pfhrp2-negative samples had no detectable HRP2/3 antigen and showed negative results for HRP2-based RDTs. pfhrp2-negative parasites were genetically less diverse and formed 2 clusters with no close relationships to parasites from Peru. These parasites probably emerged independently by selection in Eritrea. High prevalence of pfhrp2-negative parasites caused a high rate of false-negative results for RDTs. Determining prevalence of pfhrp2-negative parasites is urgently needed in neighboring countries to assist case management policies.
Van Damme, Ilse; Smets, Karolien
2014-04-01
Research has shown that emotional events are remembered better than neutral events, but might also elicit an increase in false memories. The present study was designed to disentangle the influences of valence and arousal on event memory in the misinformation paradigm. Participants were shown six types of photographs (positive with high/low arousal, negative with high/low arousal, ambiguous, neutral), after which half of them were exposed to misleading information. A recognition test assessed memory for both correct and false central and peripheral details. Negative and ambiguous events elicited fewer correct and more false memories for peripheral details than positive and neutral events, regardless of previous exposure to misinformation. Arousal improved memory for correct central details, and both negative valence and arousal inhibited control participants' tendency to endorse false central details. The power of emotion was overruled by the power of suggestion, however, as the latter effect disappeared with previous exposure to misinformation. Results are discussed in the light of earlier research on emotion and cognition, recent motivational theories, and implications for forensic practice.
Sievert, Lynnette L; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E
2010-01-01
The aims of this study were to test for a diurnal pattern in hot flashes in a multiethnic population living in a hot, humid environment and to examine the rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Study participants aged 45 to 55 years were recruited from the general population of Hilo, HI. Women wore a Biolog hot flash monitor (UFI, Morro Bay, CA), kept a diary for 24 hours, and also participated in 3-hour laboratory measures (n = 199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true-positive readings. Subjective hot flashes were considered the standard for computing false-positive and false-negative readings. True-positive, false-positive, and false-negative readings were compared across ethnic groups by chi analyses. Frequencies of sternal, nuchal, and subjective hot flashes peaked at 1500 +/- 1 hours with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true-positive measures, but nonsternal electrodes picked up more false-positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true-positive or false-positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false-negative measures). The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo were similar to results from more temperate environments. Lack of variation in sternal versus nonsternal measures and in true-positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns.
Sievert, Lynnette L.; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E.
2010-01-01
Objective To test for a diurnal pattern in hot flashes in a multi-ethnic population living in a hot, humid environment. To examine rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Methods Study participants aged 45–55 were recruited from the general population of Hilo, Hawaii. Women wore a Biolog hot flash monitor, kept a diary for 24-hours, and also participated in 3-hour laboratory measures (n=199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true positive readings. Subjective hot flashes were considered the standard for computing false positive and false negative readings. True positive, false positive, and false negative readings were compared across ethnic groups by chi-square analyses. Results Frequencies of sternal, nuchal and subjective hot flashes peaked at 15:00 ± 1 hour with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true positive measures, but non-sternal electrodes picked up more false positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true positive or false positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false negative measures). Conclusions The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo was similar to results from more temperate environments. Lack of variation in sternal vs. non-sternal measures, and in true positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns. PMID:20220538
Milhorn, Denise; Korpi-Steiner, Nichole
2015-02-01
It is unclear if the point-of-care (POC) Clinitest hCG device is subject to high-dose hook interference from physiological concentrations of intact human chorionic gonadotropin (hCG), β-core fragment of hCG (hCGβcf), and hCG free β-subunit (hCGβ) found in urine during pregnancy. We used a simulation model to address this question and related our findings to our institution's pregnant population in order to assess risk for potential false-negative hCG results. The expected distribution of days relative to ovulation during routine POC hCG testing was estimated from 182 patients. Clinitest-Clinitek Status hCG device susceptibility to high-dose hook interference from hCG variants and potential risk of false-negative results as it relates to this population were evaluated by testing increasing concentrations of hCG, hCGβcf, hCGβ as well as urine simulating physiological hCG, hCGβcf and hCGβ concentrations expected during early pregnancy (≤44 days post-ovulation). The Clinitest-Clinitek Status hCG device exhibited high-dose hook interference from hCGβcf alone, but not from hCG, hCGβ, or simulated physiological urinary concentrations of combined hCG, hCGβcf and hCGβ expected during early pregnancy. The majority of our patient population had urinary hCG testing conducted during early pregnancy. The Clinitest-Clinitek Status hCG device is unlikely to exhibit false-negative urinary hCG results due to high-dose hook interference for women in early healthy pregnancy, although additional studies are necessary to determine potential risk in other patient populations. Visual interpretation of POC urinary hCG device results is an important failure mode to consider in risk analyses for erroneous urinary hCG device results. Published by Elsevier Inc.
Flores Mateo, Gemma; Conejero, Jaume; Grenzner Martinel, Elisabet; Baba, Zeki; Dicono, Susana; Echasabal, Mildrey; Gonzalo Santos, Concepción; Aliaga, Arantxa; Barredo, María; Ruiz, Luis; Carrau, Montserrat
2010-07-01
To determine the validity of the rapid antigen test for the diagnoses of acute pharyngitis caused by group A beta-haemolytic Streptococcus (GABHS) compared with culture. Observational study of a consecutive sample of paediatric patients. Two primary care centres (PCC) from the metropolitan area of Barcelona. Children aged 1-14 years with sore throat of no more than 5 days duration were chosen at PCC. Oropharyngeal samples were collected from tonsillar bed and posterior pharynx. A rapid diagnostic test was performed, as well as a throat culture. A total of 211 patients were studied. The overall prevalence of pharyngitis due to Streptococcus was 34.1%. Compared with the throat culture, the sensitivity of the rapid test was 90.3% (95% CI: 81.0-96.0), the specificity was 78.4% (95% CI: 70.6-84.9). The percentage of false negatives was 9.7% and the false positives was 21.6%. Spectrum bias was present, inasmuch as the rapid test sensitivity increased with Centor scores. The diagnostic value of a rapid antigen test for the diagnosis of streptococcal pharyngitis in paediatric patients at PCC is high. However, the percentage of false positives and negatives is too high, and also the sensitivity is too low in patients with fewer symptoms to support the use of rapid antigenic test without culture confirmation and bacterial sensitivity test. 2009 Elsevier España, S.L. All rights reserved.
Caudullo, Giorgio; Caruso, Valentina; Cappella, Annalisa; Sguazza, Emanuela; Mazzarelli, Debora; Amadasi, Alberto; Cattaneo, Cristina
2017-01-01
When forensic pathologists and anthropologists have to deal with the evaluation of the post-mortem interval (PMI) in skeletal remains, luminol testing is frequently performed as a preliminary screening method. However, the repeatability of this test on the same bone, as well as comparative studies on different bones of the same individual, has never been performed. Therefore, with the aim of investigating the influence that different types of bones may exert on the response to the luminol test, the present study analysed three different skeletal elements (femoral diaphysis, vertebra and cranial vault), gathered from ten recent exhumed skeletons (all with a 20-year PMI). The analysis was performed twice on the same bone after 2 months: the analysis at time 0 concerned the whole bone, whereas the second concerned only a part of the same bone taken during the first test (which already had been broken). The overall results showed different responses, depending on the type of bone and on the integrity of the samples. Negative results at the first analysis (6.6% out of the total of samples) are consistent with what is reported in the literature, whilst at the second analysis, the increase of about 20% of false-negative results highlights that the luminol test ought to be performed with caution in case of broken bones or elements which are taphonomically altered. Results have thus proven that the exposition to environmental agents might result in haemoglobin (Hb) loss, as detected even after only 2 months. The study also focused on the crucial issue of the type of bone subjected to testing, remarking the suitability of the femoral diaphysis (100% of positive responses at the first analysis vs only 18% of false-negative results at the second test, corresponding to 5% of total false-negative results) as opposed to other bone elements that showed a low yield. In particular, the cranial vault gave poor results, with 40% of discrepancy between results from the two analyses, which suggests caution in choosing the type of bone sample to test. In conclusion, luminol testing should be used with caution on bones different from long bones or on non-intact bones.
Intellectual factors in false memories of patients with schizophrenia.
Zhu, Bi; Chen, Chuansheng; Loftus, Elizabeth F; Dong, Qi; Lin, Chongde; Li, Jun
2018-07-01
The current study explored the intellectual factors in false memories of 139 patients with schizophrenia, using a recognition task and an IQ test. The full-scale IQ score of the participants ranged from 57 to 144 (M = 100, SD = 14). The full IQ score had a negative correlation with false recognition in patients with schizophrenia, and positive correlations with high-confidence true recognition and discrimination rates. Further analyses with the subtests' scores revealed that false recognition was negatively correlated with scores of performance IQ (and one of its subtests: picture arrangement), whereas true recognition was positively correlated with scores of verbal IQ (and two of its subtests: information and digit span). High-IQ patients had less false recognition (overall or high-confidence false recognition), more high-confidence true recognition, and higher discrimination abilities than those with low IQ. These findings contribute to a better understanding of the cognitive mechanism in false memory of patients with schizophrenia, and are of practical relevance to the evaluation of memory reliability in patients with different intellectual levels. Copyright © 2018 Elsevier B.V. All rights reserved.
49 CFR 40.149 - May the MRO change a verified drug test result?
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false May the MRO change a verified drug test result? 40... § 40.149 May the MRO change a verified drug test result? (a) As the MRO, you may change a verified test... positive. You would change X's test result from positive to negative and contact Y to conduct a...
Plate, Andreas; Stadler, Laura; Sutter, Reto; Anagnostopoulos, Alexia; Frustaci, Dario; Zbinden, Reinhard; Fucentese, Sandro F; Zinkernagel, Annelies S; Zingg, Patrick O; Achermann, Yvonne
2018-02-26
The antimicrobial peptide α-defensin has recently been introduced as potential "single" biomarker with a high sensitivity and specificity for the preoperative diagnosis of periprosthetic joint infections (PJIs). However, most studies assessed the benefits of the test with exclusion of patients with rheumatic diseases. We aimed to evaluate the α-defensin test in a cohort study without exclusion of cases with inflammatory diseases. Between June 2016 and June 2017, we prospectively included cases with a suspected PJI and an available lateral flow test α-defensin (Synovasure®) in synovial fluid. We compared the test result to the diagnostic criteria for PJIs published by an International Consensus Group in 2013. We included 109 cases (49 hips, 60 knees) in which preoperative α-defensin tests had been performed. Thereof, 20 PJIs (16 hips, 4 knees) were diagnosed. Preoperative α-defensin tests were positive in 25 cases (22.9%) with a test sensitivity and specificity of 90% and 92.1% (95% confidence interval [CI], 68.3 - 98.8% and 84.5 - 96.8%, respectively), and a high negative predictive value of 97.6% (95% CI, 91.7 - 99.4%). We interpreted seven α-defensin tests as false positive, mainly in cases with inflammatory rheumatic diseases, including crystal deposition diseases. A negative synovial α-defensin test can reliably rule out a PJI. However, the test can be false positive in conjunction with an underlying non-infectious inflammatory disease. We therefore propose to use the α-defensin test only in addition to MSIS criteria and assessment for crystals in synovial aspirates. Copyright © 2018. Published by Elsevier Ltd.
Bertoldi, Eduardo G; Stella, Steffen F; Rohde, Luis Eduardo P; Polanczyk, Carisi A
2017-05-04
The aim of this research is to evaluate the relative cost-effectiveness of functional and anatomical strategies for diagnosing stable coronary artery disease (CAD), using exercise (Ex)-ECG, stress echocardiogram (ECHO), single-photon emission CT (SPECT), coronary CT angiography (CTA) or stress cardiacmagnetic resonance (C-MRI). Decision-analytical model, comparing strategies of sequential tests for evaluating patients with possible stable angina in low, intermediate and high pretest probability of CAD, from the perspective of a developing nation's public healthcare system. Hypothetical cohort of patients with pretest probability of CAD between 20% and 70%. The primary outcome is cost per correct diagnosis of CAD. Proportion of false-positive or false-negative tests and number of unnecessary tests performed were also evaluated. Strategies using Ex-ECG as initial test were the least costly alternatives but generated more frequent false-positive initial tests and false-negative final diagnosis. Strategies based on CTA or ECHO as initial test were the most attractive and resulted in similar cost-effectiveness ratios (I$ 286 and I$ 305 per correct diagnosis, respectively). A strategy based on C-MRI was highly effective for diagnosing stable CAD, but its high cost resulted in unfavourable incremental cost-effectiveness (ICER) in moderate-risk and high-risk scenarios. Non-invasive strategies based on SPECT have been dominated. An anatomical diagnostic strategy based on CTA is a cost-effective option for CAD diagnosis. Functional strategies performed equally well when based on ECHO. C-MRI yielded acceptable ICER only at low pretest probability, and SPECT was not cost-effective in our analysis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Individual differences in false memory from misinformation: cognitive factors.
Zhu, Bi; Chen, Chuansheng; Loftus, Elizabeth F; Lin, Chongde; He, Qinghua; Chen, Chunhui; Li, He; Xue, Gui; Lu, Zhonglin; Dong, Qi
2010-07-01
This research investigated the cognitive correlates of false memories that are induced by the misinformation paradigm. A large sample of Chinese college students (N=436) participated in a misinformation procedure and also took a battery of cognitive tests. Results revealed sizable and systematic individual differences in false memory arising from exposure to misinformation. False memories were significantly and negatively correlated with measures of intelligence (measured with Raven's Advanced Progressive Matrices and Wechsler Adult Intelligence Scale), perception (Motor-Free Visual Perception Test, Change Blindness, and Tone Discrimination), memory (Wechsler Memory Scales and 2-back Working Memory tasks), and face judgement (Face Recognition and Facial Expression Recognition). These findings suggest that people with relatively low intelligence and poor perceptual abilities might be more susceptible to the misinformation effect.
Palmier, James; Lanzrath, Brian; Dixon, Ammon; Idowu, Oluseun
2014-01-01
To identify and quantify demographic correlates of false-negative self-reporting of tobacco use in life insurance applicants. Several studies have assessed the sensitivity of self-reporting for tobacco use in various populations, but statistical examination of the causes of misreporting has been rarer. The very large (488,000 confirmed tobacco users) sample size, US-wide geographic scope, and unique incentive structure of the life insurance application process permit more robust and insurance industry-specific results in this study. Approximately 6.2 million life insurance applicants for whom both tobacco-use interview questions and a confirmatory urine cotinine test were completed between 1999 and 2012 were evaluated for consistency between self-reported and laboratory-confirmed tobacco-use status. The data set was subjected to logistic regression to identify predictors of false negative self-reports (FNSR). False-negative self-reporting was found to be strongly associated with male gender, applicant ages of less than 30 or greater than 60, and low cotinine positivity rates in the applicant's state of residence. Policy face value was also moderately predictive, values above $500,000 associated with moderately higher FNSR. The findings imply that FNSR in life insurance applicants may be the result of complex interactions among financial incentives, geography and presumptive peer groups, and gender.
Unreliable alcohol testing in a shipping safety programme.
Helander, Anders; Hagelberg, Charlotte Asker; Beck, Olof; Petrini, Björn
2009-08-10
Within a maritime alcohol and drug testing programme, a case showing an unphysiological urine ethanol concentration (235 mmol/L, 10.8 g/L) was found. The sample contained low levels of the ethanol metabolites ethyl glucuronide (EtG) and ethyl sulphate (EtS) which confirmed prior drinking, but also tested positive for the fermenting yeast Candida albicans which suggested post-sampling ethanol formation. This and other questionable cases prompted investigation of the suitability of urine alcohol testing for the intended application. Besides the routine measurements of ethanol, illicit drugs and creatinine, randomly selected ethanol-positive and ethanol-negative urines collected within the maritime programme were checked for the presence of EtG and EtS and for fungal and bacterial growth. Data on sample handling and storage was also gathered. Ten of 15 (67%) ethanol-positive and 4 of 9 (44%) ethanol-negative urines contained yeast and/or bacteria. Among the ethanol-positive cases, 4 (27%) were obviously false positives because EtG and EtS were not detected. Microbial action as the reason for false-high ethanol concentrations was indicated in other cases. When 17 bacteria-infected but fungi-negative urines were supplemented with glucose and stored for 1 week at 21 degrees C, ethanol was formed in 2 specimens containing Escherichia coli and E. coli plus P. aeruginosa. In these samples, EtG was also formed on storage while EtS was not. The routines employed for urine collection and handling within this substance abuse programme caused many false-positive identifications of alcohol use with unintended medico-legal consequences. Unpreserved urines stored without cooling should not be used for alcohol testing, given the high risk for microbial interference.
Evaluation of Second-Level Inference in fMRI Analysis
Roels, Sanne P.; Loeys, Tom; Moerkerke, Beatrijs
2016-01-01
We investigate the impact of decisions in the second-level (i.e., over subjects) inferential process in functional magnetic resonance imaging on (1) the balance between false positives and false negatives and on (2) the data-analytical stability, both proxies for the reproducibility of results. Second-level analysis based on a mass univariate approach typically consists of 3 phases. First, one proceeds via a general linear model for a test image that consists of pooled information from different subjects. We evaluate models that take into account first-level (within-subjects) variability and models that do not take into account this variability. Second, one proceeds via inference based on parametrical assumptions or via permutation-based inference. Third, we evaluate 3 commonly used procedures to address the multiple testing problem: familywise error rate correction, False Discovery Rate (FDR) correction, and a two-step procedure with minimal cluster size. Based on a simulation study and real data we find that the two-step procedure with minimal cluster size results in most stable results, followed by the familywise error rate correction. The FDR results in most variable results, for both permutation-based inference and parametrical inference. Modeling the subject-specific variability yields a better balance between false positives and false negatives when using parametric inference. PMID:26819578
Performance of an HRP-2 Rapid Diagnostic Test in Nigerian Children Less Than 5 Years of Age
Ajumobi, Olufemi; Sabitu, Kabir; Nguku, Patrick; Kwaga, Jacob; Ntadom, Godwin; Gitta, Sheba; Elizeus, Rutebemberwa; Oyibo, Wellington; Nsubuga, Peter; Maire, Mark; Poggensee, Gabriele
2015-01-01
The diagnostic performance of histidine-rich protein 2 (HRP-2)–based malaria rapid diagnostic test (RDT) was evaluated in a mesoendemic area for malaria, Kaduna, Nigeria. We compared RDT results with expert microscopy results of blood samples from 295 febrile children under 5 years. Overall, 11.9% (35/295) tested positive with RDT compared with 10.5% (31/295) by microscopy: sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 100%, 98.5%, 88.6%, and 100%, respectively. The RDT sensitivity was not affected by transmission season, parasite density, and age. Specificity and positive PV decreased slightly during the high-transmission season (97.5% and 83.3%). The RDT test positivity rates in the low- and high-transmission seasons were 9.4% and 13.5%, respectively. Overall, the test performance of this RDT was satisfactory. The findings of a low proportion of RDT false positives, no invalid and no false-negative results should validate the performance of RDTs in this context. PMID:25711608
Terakado, Shingo; Glass, Thomas R; Sasaki, Kazuhiro; Ohmura, Naoya
2014-01-01
A simple new model for estimating the screening performance (false positive and false negative rates) of a given test for a specific sample population is presented. The model is shown to give good results on a test population, and is used to estimate the performance on a sampled population. Using the model developed in conjunction with regulatory requirements and the relative costs of the confirmatory and screening tests allows evaluation of the screening test's utility in terms of cost savings. Testers can use the methods developed to estimate the utility of a screening program using available screening tests with their own sample populations.
Evaluation of the Sysmex UF1000i flow cytometer for ruling out bacterial urinary tract infection.
De Rosa, Rita; Grosso, Shamanta; Bruschetta, Graziano; Avolio, Manuela; Stano, Paola; Modolo, Maria Luisa; Camporese, Alessandro
2010-08-05
Urine culture is one of the most frequently requested tests in microbiology, and it represents the gold standard for the diagnosis of UTIs. Considering the high prevalence of negative results and the long TAT of the culture test, the use of a rapid and reliable screening method is becoming more and more important, as it reduces the workload, the TAT of negative results, and above all, unnecessary antibiotic prescription. The Sysmex UF1000i is a new urine flow cytometry analyzer capable of quantifying urinary particles, including BACT, WBCs, and YLCs. To evaluate the analytical performance of the UF1000i as a method for ruling out UTIs, we examined 1349 urine samples and compared the UF1000i results with standard urine culture results. With instrument cut-off values of 170BACTx10(6)/L and 150WBCsx10(6)/L, we obtained a sensitivity of 98.8%, a specificity of 76.5%, a NPV of 99.5%, and four false negative results (1.2%), avoiding the culture of 57.1% of samples. The Sysmex UF1000i was capable of improving the efficiency of a routine microbiology laboratory by processing 100samples/h and providing negative results in a few minutes, thus reducing unnecessary testing with an acceptable number of false negative results. In addition, the preliminary evaluation of B_FSC and B_FLH parameters from bacteria histograms seems to be useful for the distinction of bacterial strains detected (Gram-negatives versus Gram-positives). In fact when B_FSC was less than 30 ch, it allowed the distinction of Gram-negative bacteria in 97% of the samples. Copyright 2010 Elsevier B.V. All rights reserved.
Hiura, Masahito; Nakajima, Osamu; Mori, Toshizumi; Kitano, Katsuya
2005-10-01
We evaluated the accuracy of visually reading the whole blood Rapicheck H-FABP panel test using the quantitative plasma H-FABP concentration as the reference. Consecutive patients with chest pain (n = 237) who were suspected of having acute myocardial infarction were recruited. The appearance of an evident test line within 5 min was given a grade of +3 (strongly positive), appearance within 15 min +2 (moderately positive) and the appearance of a weak test line within 15 min +1 (weakly positive). The concordance rates were 91.8% for positive, 70.1% for negative and 80.2% for overall. Plasma H-FABP concentrations were above the cut-off value for 9.2% of negative (0) results. Fifty percent of weakly positive (+1) and 25.0% of moderately positive (+2) results had H-FABP concentrations lower than the cut-off value. All of the strongly positive (+3) were above the cut-off value. These results suggested that the false-positive and false-negative results of Rapicheck H-FABP were caused by over or underestimation in visual reading when the plasma H-FABP concentration was near the cut-off concentration. Low accuracy of visual reading of Rapicheck H-FABP was due to poor estimation by manual reading around the cut-off value.
Chakravorty, Soumitesh; Simmons, Ann Marie; Rowneki, Mazhgan; Parmar, Heta; Cao, Yuan; Ryan, Jamie; Banada, Padmapriya P; Deshpande, Srinidhi; Shenai, Shubhada; Gall, Alexander; Glass, Jennifer; Krieswirth, Barry; Schumacher, Samuel G; Nabeta, Pamela; Tukvadze, Nestani; Rodrigues, Camilla; Skrahina, Alena; Tagliani, Elisa; Cirillo, Daniela M; Davidow, Amy; Denkinger, Claudia M; Persing, David; Kwiatkowski, Robert; Jones, Martin; Alland, David
2017-08-29
The Xpert MTB/RIF assay (Xpert) is a rapid test for tuberculosis (TB) and rifampin resistance (RIF-R) suitable for point-of-care testing. However, it has decreased sensitivity in smear-negative sputum, and false identification of RIF-R occasionally occurs. We developed the Xpert MTB/RIF Ultra assay (Ultra) to improve performance. Ultra and Xpert limits of detection (LOD), dynamic ranges, and RIF-R rpoB mutation detection were tested on Mycobacterium tuberculosis DNA or sputum samples spiked with known numbers of M. tuberculosis H37Rv or Mycobacterium bovis BCG CFU. Frozen and prospectively collected clinical samples from patients suspected of having TB, with and without culture-confirmed TB, were also tested. For M. tuberculosis H37Rv, the LOD was 15.6 CFU/ml of sputum for Ultra versus 112.6 CFU/ml of sputum for Xpert, and for M. bovis BCG, it was 143.4 CFU/ml of sputum for Ultra versus 344 CFU/ml of sputum for Xpert. Ultra resulted in no false-positive RIF-R specimens, while Xpert resulted in two false-positive RIF-R specimens. All RIF-R-associated M. tuberculosis rpoB mutations tested were identified by Ultra. Testing on clinical sputum samples, Ultra versus Xpert, resulted in an overall sensitivity of 87.5% (95% confidence interval [CI], 82.1, 91.7) versus 81.0% (95% CI, 74.9, 86.2) and a sensitivity on sputum smear-negative samples of 78.9% (95% CI, 70.0, 86.1) versus 66.1% (95% CI, 56.4, 74.9). Both tests had a specificity of 98.7% (95% CI, 93.0, 100), and both had comparable accuracies for detection of RIF-R in these samples. Ultra should significantly improve TB detection, especially in patients with paucibacillary disease, and may provide more-reliable RIF-R detection. IMPORTANCE The Xpert MTB/RIF assay (Xpert), the first point-of-care assay for tuberculosis (TB), was endorsed by the World Health Organization in December 2010. Since then, 23 million Xpert tests have been procured in 130 countries. Although Xpert showed high overall sensitivity and specificity with pulmonary samples, its sensitivity has been lower with smear-negative pulmonary samples and extrapulmonary samples. In addition, the prediction of rifampin resistance (RIF-R) in paucibacillary samples and for a few rpoB mutations has resulted in both false-positive and false-negative results. The present study is the first demonstration of the design features and operational characteristics of an improved Xpert Ultra assay. This study also shows that the Ultra format overcomes many of the known shortcomings of Xpert. The new assay should significantly improve TB detection, especially in patients with paucibacillary disease, and provide more-reliable detection of RIF-R. Copyright © 2017 Chakravorty et al.
San Juan, R; Aguado, J M; López, M J; Lumbreras, C; Enriquez, F; Sanz, F; Chaves, F; López-Medrano, F; Lizasoain, M; Rufilanchas, J J
2005-03-01
Postsurgical mediastinitis (PSM) remains a major cause of morbidity and mortality in patients undergoing cardiac surgery procedures. Although prompt diagnosis is crucial in these patients, neither clinical data nor imaging techniques have shown enough sensitivity or specificity for early diagnosis of PSM. The aim of the present study was to assess the validity of blood cultures as a diagnostic test for the early detection of PSM in patients who become febrile after cardiac surgery procedures. During a 4-year period (1999-2002), patients who developed fever (>37.8 degrees C) in the first 60 days after a cardiac surgery procedure were evaluated. Blood cultures were drawn from these patients. PSM was defined as deep infection involving retrosternal tissue and/or the sternal bone directly observed by the surgeon and confirmed microbiologically. Three criteria for positivity of blood cultures were applied: bacteremia, staphylococcal bacteremia, or Staphylococcus aureus bacteremia. For purposes of the analysis, a positive blood culture in patients with PSM was considered a true-positive test and a negative blood culture a false-negative test. Otherwise, in febrile patients without PSM in the postsurgery period, a positive blood culture was considered a false-positive test and a negative blood culture a true-negative test. Blood cultures were drawn from 266 febrile patients in the postsurgery period. PSM occurred in 38 patients (26 cases due to S. aureus, 8 to Staphylococcus epidermidis, 3 to gram-negative enteric bacteria, and one to Pseudomonas aeruginosa). Within the 60-day postsurgical period, blood culture as a diagnostic test was most accurate in patients with S. aureus bacteremia, providing 68% sensitivity, 98% specificity, a positive predictive value of 87%, and a negative predictive value of 95%. If the analysis was limited to the period during which patients are at maximum risk for PSM (day 7-20), the values in patients with S. aureus bacteremia were as follows: 73% sensitivity, 98% specificity, 90% positive predictive value, and 93% negative predictive value. Blood culture is an accurate test for the early diagnosis of PSM in febrile patients after cardiac surgery, particularly in institutions where S. aureus is prevalent in this context. A negative blood culture practically excludes PSM and, during the period of maximum risk for PSM, the presence of S. aureus bacteremia should compel early surgical management.
Bartels, Mette Damkjaer; Boye, Kit; Rohde, Susanne Mie; Larsen, Anders Rhod; Torfs, Herbert; Bouchy, Peggy; Skov, Robert; Westh, Henrik
2009-05-01
Rapid tests for detection of methicillin-resistant Staphylococcus aureus (MRSA) carriage are important to limit the transmission of MRSA in the health care setting. We evaluated the performance of the BD GeneOhm MRSA real-time PCR assay using a diverse collection of MRSA isolates, mainly from Copenhagen, Denmark, but also including international isolates, e.g., USA100-1100. Pure cultures of 349 MRSA isolates representing variants of staphylococcal cassette chromosome mec (SCCmec) types I to V and 103 different staphylococcal protein A (spa) types were tested. In addition, 53 methicillin-susceptible Staphylococcus aureus isolates were included as negative controls. Forty-four MRSA isolates were undetectable; of these, 95% harbored SCCmec type IVa, and these included the most-common clone in Copenhagen, spa t024-sequence type 8-IVa. The false-negative MRSA isolates were tested with new primers (analyte-specific reagent [ASR] BD GeneOhm MRSA assay) supplied by Becton Dickinson (BD). The ASR BD GeneOhm MRSA assay detected 42 of the 44 isolates that were false negative in the BD GeneOhm MRSA assay. Combining the BD GeneOhm MRSA assay with the ASR BD GeneOhm MRSA assay greatly improved the results, with only two MRSA isolates being false negative. The BD GeneOhm MRSA assay alone is not adequate for MRSA detection in Copenhagen, Denmark, as more than one-third of our MRSA isolates would not be detected. We recommend that the BD GeneOhm MRSA assay be evaluated against the local MRSA diversity before being established as a standard assay, and due to the constant evolution of SCCmec cassettes, a continuous global surveillance is advisable in order to update the assay as necessary.
Dasgupta, Amitava; Wahed, Amer; Wells, Alice
2002-02-01
Several adulterants are used to mask tests for abused drugs in urine. Adulterants such as "Klear" and "Whizzies" contain potassium nitrite, and "Urine Luck" contains pyridinium chlorochromate (PCC). The presence of these adulterants cannot be detected by routine specimen integrity checks (pH, specific gravity, and temperature). We developed rapid spot tests for detecting these adulterants in urine. Addition of 3% hydrogen peroxide in urine adulterated with PCC caused rapid formation of a dark brown color. In contrast, unadulterated urine turned colorless when hydrogen peroxide was added. When urine contaminated with nitrite and 2 to 3 drops of 2N hydrochloric acid were added to 2% aqueous potassium permanganate solution, the dark pink permanganate solution turned colorless immediately with effervescence. Urine contaminated with nitrite liberated iodine from potassium iodide solution in the presence of 2N hydrochloric acid. Urine adulterated with PCC also liberated iodine from potassium iodide in acid medium but did not turn potassium permanganate solution colorless. Urine specimens from volunteers and random urine samples that tested negative for drugs did not cause false-positive results. These rapid spot tests are useful for detecting adulterated urine to avoid false-negative drug tests.
Huo, Yuankai; Xu, Zhoubing; Bao, Shunxing; Bermudez, Camilo; Plassard, Andrew J.; Liu, Jiaqi; Yao, Yuang; Assad, Albert; Abramson, Richard G.; Landman, Bennett A.
2018-01-01
Spleen volume estimation using automated image segmentation technique may be used to detect splenomegaly (abnormally enlarged spleen) on Magnetic Resonance Imaging (MRI) scans. In recent years, Deep Convolutional Neural Networks (DCNN) segmentation methods have demonstrated advantages for abdominal organ segmentation. However, variations in both size and shape of the spleen on MRI images may result in large false positive and false negative labeling when deploying DCNN based methods. In this paper, we propose the Splenomegaly Segmentation Network (SSNet) to address spatial variations when segmenting extraordinarily large spleens. SSNet was designed based on the framework of image-to-image conditional generative adversarial networks (cGAN). Specifically, the Global Convolutional Network (GCN) was used as the generator to reduce false negatives, while the Markovian discriminator (PatchGAN) was used to alleviate false positives. A cohort of clinically acquired 3D MRI scans (both T1 weighted and T2 weighted) from patients with splenomegaly were used to train and test the networks. The experimental results demonstrated that a mean Dice coefficient of 0.9260 and a median Dice coefficient of 0.9262 using SSNet on independently tested MRI volumes of patients with splenomegaly.
Quality assuring HIV point of care testing using whole blood samples.
Dare-Smith, Raellene; Badrick, Tony; Cunningham, Philip; Kesson, Alison; Badman, Susan
2016-08-01
The Royal College of Pathologists Australasia Quality Assurance Programs (RCPAQAP), have offered dedicated external quality assurance (EQA) for HIV point of care testing (PoCT) since 2011. Prior to this, EQA for these tests was available within the comprehensive human immunodeficiency virus (HIV) module. EQA testing for HIV has typically involved the supply of serum or plasma, while in the clinic or community based settings HIV PoCT is generally performed using whole blood obtained by capillary finger-stick collection. RCPAQAP has offered EQA for HIV PoCT using stabilised whole blood since 2014. A total of eight surveys have been undertaken over a period of 2 years from 2014 to 2015. Of the 962 responses received, the overall consensus rate was found to be 98% (941/962). A total of 21 errors were detected. The majority of errors were attributable to false reactive HIV p24 antigen results (9/21, 43%), followed by false reactive HIV antibody results (8/21, 38%). There were 4/21 (19%) false negative HIV antibody results and no false negative HIV p24 antigen results reported. Overall performance was observed to vary minimally between surveys, from a low of 94% up to 99% concordant. Encouraging levels of testing proficiency for HIV PoCT are indicated by these data, but they also confirm the need for HIV PoCT sites to participate in external quality assurance programs to ensure the ongoing provision of high quality patient care. Copyright © 2016 Royal College of Pathologists of Australasia. All rights reserved.
49 CFR 40.161 - What does the MRO do when a drug test specimen is rejected for testing?
Code of Federal Regulations, 2011 CFR
2011-10-01
... negative test is required (e.g., in the case of a pre-employment, return-to-duty, or follow-up test). (c... 49 Transportation 1 2011-10-01 2011-10-01 false What does the MRO do when a drug test specimen is... Verification Process § 40.161 What does the MRO do when a drug test specimen is rejected for testing? As the...
49 CFR 40.161 - What does the MRO do when a drug test specimen is rejected for testing?
Code of Federal Regulations, 2010 CFR
2010-10-01
... negative test is required (e.g., in the case of a pre-employment, return-to-duty, or follow-up test). (c... 49 Transportation 1 2010-10-01 2010-10-01 false What does the MRO do when a drug test specimen is... Verification Process § 40.161 What does the MRO do when a drug test specimen is rejected for testing? As the...
49 CFR 40.161 - What does the MRO do when a drug test specimen is rejected for testing?
Code of Federal Regulations, 2012 CFR
2012-10-01
... negative test is required (e.g., in the case of a pre-employment, return-to-duty, or follow-up test). (c... 49 Transportation 1 2012-10-01 2012-10-01 false What does the MRO do when a drug test specimen is... Verification Process § 40.161 What does the MRO do when a drug test specimen is rejected for testing? As the...
49 CFR 40.161 - What does the MRO do when a drug test specimen is rejected for testing?
Code of Federal Regulations, 2014 CFR
2014-10-01
... negative test is required (e.g., in the case of a pre-employment, return-to-duty, or follow-up test). (c... 49 Transportation 1 2014-10-01 2014-10-01 false What does the MRO do when a drug test specimen is... Verification Process § 40.161 What does the MRO do when a drug test specimen is rejected for testing? As the...
49 CFR 40.161 - What does the MRO do when a drug test specimen is rejected for testing?
Code of Federal Regulations, 2013 CFR
2013-10-01
... negative test is required (e.g., in the case of a pre-employment, return-to-duty, or follow-up test). (c... 49 Transportation 1 2013-10-01 2013-10-01 false What does the MRO do when a drug test specimen is... Verification Process § 40.161 What does the MRO do when a drug test specimen is rejected for testing? As the...
Sensitivity and Specificity of Histoplasma Antigen Detection by Enzyme Immunoassay.
Cunningham, Lauren; Cook, Audrey; Hanzlicek, Andrew; Harkin, Kenneth; Wheat, Joseph; Goad, Carla; Kirsch, Emily
2015-01-01
The objective of this study was to evaluate the sensitivity and specificity of an antigen enzyme immunoassay (EIA) on urine samples for the diagnosis of histoplasmosis in dogs. This retrospective medical records review included canine cases with urine samples submitted for Histoplasma EIA antigen assay between 2007 and 2011 from three veterinary institutions. Cases for which urine samples were submitted for Histoplasma antigen testing were reviewed and compared to the gold standard of finding Histoplasma organisms or an alternative diagnosis on cytology or histopathology. Sensitivity, specificity, negative predictive value, positive predictive value, and the kappa coefficient and associated confidence interval were calculated for the EIA-based Histoplasma antigen assay. Sixty cases met the inclusion criteria. Seventeen cases were considered true positives based on identification of the organism, and 41 cases were considered true negatives with an alternative definitive diagnosis. Two cases were considered false negatives, and there were no false positives. Sensitivity was 89.47% and the negative predictive value was 95.35%. Specificity and the positive predictive value were both 100%. The kappa coefficient was 0.9207 (95% confidence interval, 0.8131-1). The Histoplasma antigen EIA test demonstrated high specificity and sensitivity for the diagnosis of histoplasmosis in dogs.
[Evaluation of quality of HIV diagnostic procedures in Poland].
Parczewski, Miłosz; Madaliński, Kazimierz; Leszczyszyn-Pynka, Magdalena; Boroń-Kaczmarska, Anna
2010-01-01
The aim of this work was quality assessment of HIV diagnostic procedures in Poland, including human and technical resources as well as laboratory practice. Sixty questionnaires were distributed among diagnostic centers to obtain qualitative data. Basing on the survey data serological control using coded panels of HIV-1/2 samples was performed. Thirty-one filled questionnaires were received (50.8%). Surveyed laboratories perform from 350 to 5500 serological screening tests per year. In most of laboratories fourth generation assays are available, while Blood Donation Centers screen the blood both with serological assays and by HIV-RNA detection. Sanitary and Epidemiological Stations and academic laboratories hold the ISO/IEC 17025 or IS0 9001:2001 accreditation, five of the surveyed centers participate in Labquality assurance and two in Quality Control in Molecular Diagnostics programs. Data of control serological testing were received from 21 centers. In the quality control assessment 194 analyses were performed with 91 true negative, 2 false negative, 96 true positive and 5 false positive results. False negative rate of % and false positive rate of 5.2% was noted for this study. Currently, virtually no guidelines related to the HIV-diagnostics quality assurance and control in Poland are in delineated. Development of the national unified quality control system, basing on the central institution is highly desirable. National certification within the frames of the quality control and assurance program should be mandatory for all the diagnostic labs, and aim at improvement of reliability of the result distributed among clinicians and patients.
False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.
Tenore, Peter L
2012-01-01
In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.
Maltha, Jessica; Gillet, Philippe; Heutmekers, Marloes; Bottieau, Emmanuel; Van Gompel, Alfons; Jacobs, Jan
2013-01-01
In the past malaria rapid diagnostic tests (RDTs) for self-diagnosis by travelers were considered suboptimal due to poor performance. Nowadays RDTs for self-diagnosis are marketed and available through the internet. The present study assessed RDT products marketed for self-diagnosis for diagnostic accuracy and quality of labeling, content and instructions for use (IFU). Diagnostic accuracy of eight RDT products was assessed with a panel of stored whole blood samples comprising the four Plasmodium species (n = 90) as well as Plasmodium negative samples (n = 10). IFUs were assessed for quality of description of procedure and interpretation and for lay-out and readability level. Errors in packaging and content were recorded. Two products gave false-positive test lines in 70% and 80% of Plasmodium negative samples, precluding their use. Of the remaining products, 4/6 had good to excellent sensitivity for the diagnosis of Plasmodium falciparum (98.2%-100.0%) and Plasmodium vivax (93.3%-100.0%). Sensitivity for Plasmodium ovale and Plasmodium malariae diagnosis was poor (6.7%-80.0%). All but one product yielded false-positive test lines after reading beyond the recommended reading time. Problems with labeling (not specifying target antigens (n = 3), and content (desiccant with no humidity indicator (n = 6)) were observed. IFUs had major shortcomings in description of test procedure and interpretation, poor readability and lay-out and user-unfriendly typography. Strategic issues (e.g. the need for repeat testing and reasons for false-negative tests) were not addressed in any of the IFUs. Diagnostic accuracy of RDTs for self-diagnosis was variable, with only 4/8 RDT products being reliable for the diagnosis of P. falciparum and P. vivax, and none for P. ovale and P. malariae. RDTs for self-diagnosis need improvements in IFUs (content and user-friendliness), labeling and content before they can be considered for self-diagnosis by the traveler.
Maltha, Jessica; Gillet, Philippe; Heutmekers, Marloes; Bottieau, Emmanuel; Van Gompel, Alfons; Jacobs, Jan
2013-01-01
Introduction In the past malaria rapid diagnostic tests (RDTs) for self-diagnosis by travelers were considered suboptimal due to poor performance. Nowadays RDTs for self-diagnosis are marketed and available through the internet. The present study assessed RDT products marketed for self-diagnosis for diagnostic accuracy and quality of labeling, content and instructions for use (IFU). Methods Diagnostic accuracy of eight RDT products was assessed with a panel of stored whole blood samples comprising the four Plasmodium species (n = 90) as well as Plasmodium negative samples (n = 10). IFUs were assessed for quality of description of procedure and interpretation and for lay-out and readability level. Errors in packaging and content were recorded. Results Two products gave false-positive test lines in 70% and 80% of Plasmodium negative samples, precluding their use. Of the remaining products, 4/6 had good to excellent sensitivity for the diagnosis of Plasmodium falciparum (98.2%–100.0%) and Plasmodium vivax (93.3%–100.0%). Sensitivity for Plasmodium ovale and Plasmodium malariae diagnosis was poor (6.7%–80.0%). All but one product yielded false-positive test lines after reading beyond the recommended reading time. Problems with labeling (not specifying target antigens (n = 3), and content (desiccant with no humidity indicator (n = 6)) were observed. IFUs had major shortcomings in description of test procedure and interpretation, poor readability and lay-out and user-unfriendly typography. Strategic issues (e.g. the need for repeat testing and reasons for false-negative tests) were not addressed in any of the IFUs. Conclusion Diagnostic accuracy of RDTs for self-diagnosis was variable, with only 4/8 RDT products being reliable for the diagnosis of P. falciparum and P. vivax, and none for P. ovale and P. malariae. RDTs for self-diagnosis need improvements in IFUs (content and user-friendliness), labeling and content before they can be considered for self-diagnosis by the traveler. PMID:23301027
The false-negative rate of sentinel node biopsy in patients with breast cancer: a meta-analysis
Pesek, Sarah; Ashikaga, Taka; Krag, Lars Erik; Krag, David
2012-01-01
Background/Purpose In sentinel node surgery for breast cancer, procedural accuracy is assessed by calculating the false-negative rate. It is important to measure this since there are potential adverse outcomes from missing node metastases. We performed a meta-analysis of published data to assess which method has achieved the lowest false-negative rate. Methods We found 3588 articles concerning sentinel nodes and breast cancer published from 1993 through mid-2011; 183 articles met our inclusion criteria. The studies described in these 183 articles included a total of 9306 patients. We grouped the studies by injection material and injection location. The false-negative rates were analyzed according to these groupings and also by the year in which the articles were published. Results There was significant variation in the false-negative rate over time with a trend to higher rates over time. There was significant variation related to injection material. The use of blue dye alone was associated with the highest false-negative rate. Inclusion of a radioactive tracer along with blue dye resulted in a significantly lower false-negative rate. Although there were variations in the false-negative rate according to injection location, none were significant. This meta-analysis also indicates a significant change over time in the false-negative rate. Discussion/Conclusions The use of blue dye should be accompanied by a radioactive tracer to achieve a significantly lower false-negative rate. Location of injection did not have a significant impact on the false-negative rate. Given the limitations of acquiring appropriate data, the false-negative rate should not be used as a metric for training or quality control. PMID:22569745
Occupancy Modeling for Improved Accuracy and Understanding of Pathogen Prevalence and Dynamics
Colvin, Michael E.; Peterson, James T.; Kent, Michael L.; Schreck, Carl B.
2015-01-01
Most pathogen detection tests are imperfect, with a sensitivity < 100%, thereby resulting in the potential for a false negative, where a pathogen is present but not detected. False negatives in a sample inflate the number of non-detections, negatively biasing estimates of pathogen prevalence. Histological examination of tissues as a diagnostic test can be advantageous as multiple pathogens can be examined and providing important information on associated pathological changes to the host. However, it is usually less sensitive than molecular or microbiological tests for specific pathogens. Our study objectives were to 1) develop a hierarchical occupancy model to examine pathogen prevalence in spring Chinook salmon Oncorhynchus tshawytscha and their distribution among host tissues 2) use the model to estimate pathogen-specific test sensitivities and infection rates, and 3) illustrate the effect of using replicate within host sampling on sample sizes required to detect a pathogen. We examined histological sections of replicate tissue samples from spring Chinook salmon O. tshawytscha collected after spawning for common pathogens seen in this population: Apophallus/echinostome metacercariae, Parvicapsula minibicornis, Nanophyetus salmincola/ metacercariae, and Renibacterium salmoninarum. A hierarchical occupancy model was developed to estimate pathogen and tissue-specific test sensitivities and unbiased estimation of host- and organ-level infection rates. Model estimated sensitivities and host- and organ-level infections rates varied among pathogens and model estimated infection rate was higher than prevalence unadjusted for test sensitivity, confirming that prevalence unadjusted for test sensitivity was negatively biased. The modeling approach provided an analytical approach for using hierarchically structured pathogen detection data from lower sensitivity diagnostic tests, such as histology, to obtain unbiased pathogen prevalence estimates with associated uncertainties. Accounting for test sensitivity using within host replicate samples also required fewer individual fish to be sampled. This approach is useful for evaluating pathogen or microbe community dynamics when test sensitivity is <100%. PMID:25738709
Occupancy modeling for improved accuracy and understanding of pathogen prevalence and dynamics
Colvin, Michael E.; Peterson, James T.; Kent, Michael L.; Schreck, Carl B.
2015-01-01
Most pathogen detection tests are imperfect, with a sensitivity < 100%, thereby resulting in the potential for a false negative, where a pathogen is present but not detected. False negatives in a sample inflate the number of non-detections, negatively biasing estimates of pathogen prevalence. Histological examination of tissues as a diagnostic test can be advantageous as multiple pathogens can be examined and providing important information on associated pathological changes to the host. However, it is usually less sensitive than molecular or microbiological tests for specific pathogens. Our study objectives were to 1) develop a hierarchical occupancy model to examine pathogen prevalence in spring Chinook salmonOncorhynchus tshawytscha and their distribution among host tissues 2) use the model to estimate pathogen-specific test sensitivities and infection rates, and 3) illustrate the effect of using replicate within host sampling on sample sizes required to detect a pathogen. We examined histological sections of replicate tissue samples from spring Chinook salmon O. tshawytscha collected after spawning for common pathogens seen in this population:Apophallus/echinostome metacercariae, Parvicapsula minibicornis, Nanophyetus salmincola/metacercariae, and Renibacterium salmoninarum. A hierarchical occupancy model was developed to estimate pathogen and tissue-specific test sensitivities and unbiased estimation of host- and organ-level infection rates. Model estimated sensitivities and host- and organ-level infections rates varied among pathogens and model estimated infection rate was higher than prevalence unadjusted for test sensitivity, confirming that prevalence unadjusted for test sensitivity was negatively biased. The modeling approach provided an analytical approach for using hierarchically structured pathogen detection data from lower sensitivity diagnostic tests, such as histology, to obtain unbiased pathogen prevalence estimates with associated uncertainties. Accounting for test sensitivity using within host replicate samples also required fewer individual fish to be sampled. This approach is useful for evaluating pathogen or microbe community dynamics when test sensitivity is <100%.
Husain, Shahid; Kwak, Eun Jeong; Obman, Asia; Wagener, Marilyn M; Kusne, Shimon; Stout, Janet E; McCurry, Kenneth R; Singh, Nina
2004-05-01
The clinical utility of Platelia trade mark Aspergillus galactomannan antigen for the early diagnosis of invasive aspergillosis was prospectively assessed in 70 consecutive lung transplant recipients. Sera were collected twice weekly and tested for galactomannan. Invasive aspergillosis was documented in 17.1% (12/70) of the patients. Using the generalized estimating equation model, at the cutoff value of >or= 0.5, the sensitivity of the test was 30%, specificity 93% with positive and negative likelihood ratios of 4.2 and 0.75, respectively. Increasing the cutoff value to >or= 0.66 yielded a sensitivity of 30%, specificity of 95%, and positive and negative likelihood ratios of 5.5 and 0.74. A total of 14 patients had false-positive tests, including nine who had cystic fibrosis or chronic obstructive pulmonary disease. False-positive tests occurred within 3 days of transplantation in 43% (6/14) of the patients, and within 7 days in 64% (9/14). Thus, the test demonstrated excellent specificity, but a low sensitivity for the diagnosis of aspergillosis in this patient population. Patients with cystic fibrosis or chronic obstructive pulmonary disease may transiently have a positive test in the early post-transplant period.
Jacobson, Gary P; McCaslin, Devin L; Piker, Erin G; Gruenwald, Jill; Grantham, Sarah; Tegel, Lauren
2011-01-01
The objective of this study was to assess the sensitivity, specificity, and positive and negative predictive value of the Romberg Test of Standing Balance on Firm and Compliant Support Surfaces (RTSBFCSS) for the identification of patients with vestibular system impairments affecting the horizontal semicircular canal, saccule, and/or inferior and superior vestibular nerves. The RTSBFCSS was developed for the National Health and Nutrition Examination Survey (NHANES) and was used recently to estimate the numbers of individuals aged 40 yr or older with vestibular system impairments among the general population of the United States. A retrospective analysis of the medical records of 103 consecutive patients aged 40 yr or older (mean age 59 ± 12 yr, 71 females) who had undergone vestibular assessment at the Balance Disorders Clinic at the Vanderbilt University School of Medicine. Patients with complete electro- or videonystagmography testing, cervical vestibular evoked myogenic potential (cVEMP) testing, and the RTSBFCSS screening test were included in the analysis. A series of 2 × 2 tables were created that represented the number of "true positives," "true negatives," "false positives," and "false negatives" of the RTSBFCSS under conditions where the caloric test was abnormal and then separately where the cVEMP test was abnormal. The data were analyzed in a manner such that sensitivity, specificity, and both positive and negative predictive value of the RTSBFCSS could be calculated. When the caloric test was used as the criterion standard and the subject selection criteria in the NHANES study were used (i.e., subjects who were able to maintain postural stability for trials 1-3 of the RTSBFCSS; N = 45), the sensitivity and specificity of the RTSBFCSS to impairment of the horizontal semicircular canal or superior vestibular nerve were 55% and 64%, respectively, yielding positive and negative predictive values of 55% and 64%, respectively. When all patients aged 40 yr or older were evaluated (N = 103), the sensitivity and specificity were 61% and 58%, respectively, yielding positive and negative predictive values of 39% and 78%, respectively. Using the cVEMP test as the criterion standard for the detection of impairment affecting the saccule and/or inferior vestibular nerve did not improve the performance criteria of the NHANES screening measure. The RTSBFCSS should not be used as a screening measure for vestibular impairment.
Dassanayake, Dinesh L B; Wimalaratna, Harith; Agampodi, Suneth B; Liyanapathirana, Veranja C; Piyarathna, Thibbotumunuwe A C L; Goonapienuwala, Bimba L
2009-04-22
Leptospirosis is endemic in both urban and rural areas of Sri Lanka and there had been many out breaks in the recent past. This study was aimed at validating the leptospirosis surveillance case definition, using the Microscopic Agglutination Test (MAT). The study population consisted of patients with undiagnosed acute febrile illness who were admitted to the medical wards of the Teaching Hospital Kandy, from 1st July 2007 to 31st July 2008. The subjects were screened to diagnose leptospirosis according to the leptospirosis case definition. MAT was performed on blood samples taken from each patient on the 7th day of fever. Leptospirosis case definition was evaluated in regard to sensitivity, specificity and predictive values, using a MAT titre >or= 1:800 for confirming leptospirosis. A total of 123 patients were initially recruited of which 73 had clinical features compatible with the surveillance case definition. Out of the 73 only 57 had a positive MAT result (true positives) leaving 16 as false positives. Out of the 50 who didn't have clinical features compatible with the case definition 45 had a negative MAT as well (true negatives), therefore 5 were false negatives. Total number of MAT positives was 62 out of 123. According to these results the test sensitivity was 91.94%, specificity 73.77%, positive predictive value and negative predictive values were 78.08% and 90% respectively. Diagnostic accuracy of the test was 82.93%. This study confirms that the surveillance case definition has a very high sensitivity and negative predictive value with an average specificity in diagnosing leptospirosis, based on a MAT titre of >or= 1: 800.
Marzulli, F; Maguire, H C
1982-02-01
Several guinea-pig predictive test methods were evaluated by comparison of results with those obtained with human predictive tests, using ten compounds that have been used in cosmetics. The method involves the statistical analysis of the frequency with which guinea-pig tests agree with the findings of tests in humans. In addition, the frequencies of false positive and false negative predictive findings are considered and statistically analysed. The results clearly demonstrate the superiority of adjuvant tests (complete Freund's adjuvant) in determining skin sensitizers and the overall superiority of the guinea-pig maximization test in providing results similar to those obtained by human testing. A procedure is suggested for utilizing adjuvant and non-adjuvant test methods for characterizing compounds as of weak, moderate or strong sensitizing potential.
NASA Astrophysics Data System (ADS)
Wang, Jing; Feng, Shangyuan; Lin, Juqiang; Zeng, Yongyi; Li, Ling; Huang, Zufang; Li, Buhong; Zeng, Haishan; Chen, Rong
2013-11-01
Surface-enhanced Raman spectroscopy (SERS) of serum albumin and globulin were employed to detect hepatocellular carcinoma (HCC). Tentative assignments of SERS bands show specific biomolecular changes associated with cancer development. These changes include a decrease in relative amounts of tryptophan, glutamine, glycine, and serine, indicating excessive consumption of amino acids for protein duplication. Principal component analysis was also introduced to analyze the obtained spectra, resulting in both diagnostic sensitivity and specificity of 100%. More importantly, it reveals that this method can detect HCC patients with alpha-fetoprotein negative test results, suggesting its great potential as a new alternative to detect HCC.
Wang, Li-jun; Lu, Xin-xin; Wu, Wei; Sui, Wen-jun; Zhang, Gui
2014-01-01
In order to evaluate a rapid matrix-assisted laser desorption ionization-time of flight mass spectrometry (MAIDI-TOF MS) assay in screening vancomycin-resistant Enterococcus faecium, a total of 150 E. faecium clinical strains were studied, including 60 vancomycin-resistant E. faecium (VREF) isolates and 90 vancomycin-susceptible (VSEF) strains. Vancomycin resistance genes were detected by sequencing. E. faecium were identified by MALDI-TOF MS. A genetic algorithm model with ClinProTools software was generated using spectra of 30 VREF isolates and 30 VSEF isolates. Using this model, 90 test isolates were discriminated between VREF and VSEF. The results showed that all sixty VREF isolates carried the vanA gene. The performance of VREF detection by the genetic algorithm model of MALDI-TOF MS compared to the sequencing method was sensitivity = 80%, specificity = 90%, false positive rate =10%, false negative rate =10%, positive predictive value = 80%, negative predictive value= 90%. MALDI-TOF MS can be used as a screening test for discrimination between vanA-positive E. faecium and vanA-negative E. faecium.
Bion, Cindy; Beck Henzelin, Andrea; Qu, Yajuan; Pizzocri, Giuseppe; Bolzoni, Giuseppe; Buffoli, Elena
2016-01-01
Delvotest® T was evaluated for its capability at detecting residues of 27 antibiotics in raw cow's milk and in some dairy ingredients (skimmed and full-cream milk powders). The kit was used as a screening tool for the qualitative determination of antibiotics from different families in a single test. Results delivered by such a method are expressed as 'positive' or 'negative', referring to the claimed screening target concentration (STC). Validation was conducted according to the European Community Reference Laboratories' (CRLs) residues guidelines of 20 January 2010 and performed by two laboratories, one located in Europe and the other in Asia. Five criteria were evaluated including detection capability at STC, false-positive (FP) rate, false-negative (FN) rate, robustness and cross-reactivity using visual reading and Delvoscan®. STCs were set at or below the corresponding maximum residue limit (MRL), as fixed by European Regulation EC No. 37/2010. Four antibiotics (nafcillin, oxytetracycline, tetracycline and rifaximin) out of 27 had a false-negative rate ranging from 1.7% to 4.9%; however, it was still compliant with the CRLs' requirements. Globally, Delvotest T can be recommended for the analysis of the surveyed antibiotics in raw cow's milk, skimmed and full-cream milk powders. Additional compounds were tested such as sulfamethazine, spiramycin and erythromycin; however, detection at the corresponding MRL was not achievable and these compounds were removed from the validation. Other drugs from the sulfonamide, aminoglycoside or macrolide families not detected by the test at the MRL were not evaluated in this study. Regarding the reliability of this rapid test to milk-based preparations, additional experiments should be performed on a larger range of compounds and samples to validate the Delvotest T in such matrices.
Six consecutive false positive cases from cell-free fetal DNA testing in a single referring centre
Dugo, Nella; Padula, Francesco; Mobili, Luisa; Brizzi, Cristiana; D’Emidio, Laura; Cignini, Pietro; Mesoraca, Alvaro; Bizzoco, Domenico; Cima, Antonella; Giorlandino, Claudio
2014-01-01
Introduction recent studies have proposed the introduction of cell-free fetal DNA testing (NIPT-Non Invasive Prenatal Testing) in routine clinical practice emphasizing its high sensibility and specificity. In any case, false positive and false negative findings may result from placental mosaicism, because cell-free fetal DNA originates mainly from placenta. Case we report six cases of women who underwent chorionic villus sampling (CVS) or amniocentesis to confirm the results from NIPT: two Turner syndromes, two Triple X, one Patau syndrome, one Edward syndrome. Results using classic cytogenetic analysis and, also, Array - Comparative Genomic Hybridization (Array CGH) the karyotype of all 5 fetuses was found to be normal. Conclusion results from NIPT must always be confirmed by invasive prenatal diagnosis. It is mandatory to inform the patient that the CVS and amniocentesis still represent the only form of prenatal diagnostic test available. PMID:25332757
Thorley, Nicola; Adebayo, Michael; Smit, Erasmus; Radcliffe, Keith
2016-08-01
An unconfirmed positive treponemal enzyme immunoassay (enzyme immunoassay positive, Treponema pallidum particle agglutination negative and rapid plasma reagin negative) presents a clinical challenge to distinguish early syphilis infection from false-positive results. These cases are referred for syphilis line assay (INNO-LIA) and recalled for repeat syphilis serology. We performed a retrospective audit to establish the proportion of HIV-negative cases with unconfirmed positive enzyme immunoassay results, the proportion of these cases that received an INNO-LIA test and repeat syphilis serology testing and reviewed the clinical outcomes; 0.35% (80/22687) cases had an unconfirmed positive treponemal enzyme immunoassay result. Repeat syphilis serology was performed in 80% (64/80) cases, but no additional cases of syphilis were identified. Eighty-eight per cent (70/80) received an INNO-LIA test; 14% (5/37) unconfirmed enzyme immunoassay-positive cases with no prior history of syphilis were confirmed on INNO-LIA assay, supporting a diagnosis of latent syphilis. As a confirmatory treponemal test, the INNO-LIA assay may be more useful than repeat syphilis serological testing. © The Author(s) 2016.
Lahuerta-Marin, Angela; McNair, James; Skuce, Robin; McBride, Stewart; Allen, Michelle; Strain, Sam A J; Menzies, Fraser D; McDowell, Stanley J W; Byrne, Andrew W
2016-08-01
Correctly identifying animals that are truly infected with a pathogen using ante-mortem tests is the cornerstone of any disease eradication programme. Failure to identify all infected animals will impede the progress towards controlling and eradicating disease and may also have unforeseen consequences when specific prevention measures are in place to avoid animal-to-animal transmission. In the case of bovine tuberculosis (bTB), the screening ante-mortem test, the Single Comparative Intradermal Tuberculin Test (SCITT), can exhibit moderate sensitivity which can result in a "hidden burden" of infection residing within the population. Using an animal-level dataset relating to the disclosure of infected cattle with Mycobacterium bovis, the causative agent of bTB within infected herds in Northern Ireland, we investigated what factors influenced the probability of an animal being a false-negative when truly infected (using post-mortem (PM) microbiological culture confirmation results to assess infection status). We found that different risk factors affected the probability of a test-negative outcome on infected animals depending on the ante-mortem test or their combination (SICTT and/or interferon gamma (IFN-ɣ) testing). Using multivariable models, SCITT disclosure performance varied significantly by age, location (region), and production type. The IFN-ɣ tests were significantly affected by region or season, but these effects depended on the cut-off used during interpretation of the test which affected the tests characteristics. Parallel use of SCITT and IFN-ɣ tests resulted in the least number of false-negatives, and their disclosure was affected by season and age-class. Understanding the factors that lead to the non-disclosure of infected animals is essential to optimise large-scale bTB disease eradication programmes. Copyright © 2016. Published by Elsevier Ltd.
Brain dead or not? CT angiogram yielding false-negative result on brain death confirmation.
Johnston, Robyn; Kaliaperumal, Chandrasekaran; Wyse, Gerald; Kaar, George
2013-01-08
We describe a case of severe traumatic brain injury with multiple facial and skull fractures where CT angiogram (CTA) failed to yield a definite result of brain death as an ancillary test. A 28-year-old man was admitted following a road traffic accident with a Glasgow Coma Score (GCS) of 3/15 and fixed pupils. CT brain revealed uncal herniation and diffuse cerebral oedema with associated multiple facial and skull fractures. 72 h later, his clinical condition remained the same with high intracranial pressure refractory to medical management. Clinical confirmation on brain death was not feasible owing to facial injuries. A CTA, performed to determine brain perfusion, yielded a 'false-negative' result. Skull fractures have possibly led to venous prominence in the cortical and deep venous drainage system. This point needs to be borne in mind while considering CTA as an ancillary test to confirm brain death.
Piwowar-Manning, Estelle; Fogel, Jessica M.; Richardson, Paul; Wolf, Shauna; Clarke, William; Marzinke, Mark A.; Fiamma, Agnès; Donnell, Deborah; Kulich, Michal; Mbwambo, Jessie K.K.; Richter, Linda; Gray, Glenda; Sweat, Michael; Coates, Thomas J.; Eshleman, Susan H.
2015-01-01
Background Fourth-generation HIV assays detect both antigen and antibody, facilitating detection of acute/early HIV infection. The Bio-Rad GS HIV Combo Ag/Ab assay (Bio-Rad Combo) is an enzyme immunoassay that simultaneously detects HIV p24 antigen and antibodies to HIV-1 and HIV-2 in serum or plasma. Objective To evaluate the performance of the Bio-Rad Combo assay for detection of HIV infection in adults from Southern Africa. Study design Samples were obtained from adults in Soweto and Vulindlela, South Africa and Dar es Salaam, Tanzania (300 HIV-positive samples; 300 HIV-negative samples; 12 samples from individuals previously classified as having acute/early HIV infection). The samples were tested with the Bio-Rad Combo assay. Additional testing was performed to characterize the 12 acute/early samples. Results All 300 HIV-positive samples were reactive using the Bio-Rad Combo assay; false positive test results were obtained for 10 (3.3%) of the HIV-negative samples (sensitivity: 100%, 95% confidence interval [CI]: 98.8–100%); specificity: 96.7%, 95% CI: 94.0–98.4%). The assay detected 10 of the 12 infections classified as acute/early. The two infections that were not detected had viral loads < 400 copies/mL; one of those samples contained antiretroviral drugs consistent with antiretroviral therapy. Conclusions The Bio-Rad Combo assay correctly classified the majority of study specimens. The specificity reported here may be higher than that seen in other settings, since HIV-negative samples were pre-screened using a different fourth-generation test. The assay also had high sensitivity for detection of acute/early infection. False-negative test results may be obtained in individuals who are virally suppressed. PMID:25542477
Use of the Abbott Architect HIV antigen/antibody assay in a low incidence population.
Dubravac, Terry; Gahan, Thomas F; Pentella, Michael A
2013-12-01
With the availability of 4th generation HIV diagnostic tests which are capable of detecting acute infection, Iowa evaluated the 3rd and 4th generation HIV test and compared the performance of these products in a low incidence population. This study was conducted to evaluate the performance of an HIV antigen/antibody combination (4th generation) assay compared to an EIA 3rd generation assay. Over a 4 month period, 2037 specimens submitted for HIV screening were tested by Bio-Rad GS HIV-1/HIV-2 Plus O EIA and the Abbott Architect i1000SR HIV Ag/Ab Combo. The performance characteristics of sensitivity, specificity, positive predictive value and negative predictive value were determined. Of the 2037 specimens tested, there were 13 (0.64%) true positives detected. None of the positive specimens were from patients in the acute phase of infection. The Abbott antigen/antibody combo assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.85%, 81.25%, and 100% respectively. The Bio-Rad EIA assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.80%, 76.47% and 100%, respectively. The EIA had four false positive results which tested negative by the antigen/antibody assay and western blot. In a low-incidence state where early infections are less commonly encountered, the EIA assay and the antigen/antibody assay performed with near equivalency. The antigen/antibody assay had one less false positive result. While no patients were detected in the acute stage of infection, the use of the antigen/antibody assay presents the opportunity to detect an infected patient sooner and prevent transmission to others. Copyright © 2013 Elsevier B.V. All rights reserved.
Shimelis, Techalew; Tadesse, Endale
2015-01-01
Objective To determine the diagnostic performance of the SD BIOLINE HIV/syphilis Duo rapid test. Design A hospital-based cross-sectional study. Setting This evaluation was conducted at one of the largest hospitals in southern Ethiopia. Participants Serum samples obtained from clients attending the antiretroviral therapy and voluntary counselling and testing centres were used. Sera were originally collected for the purpose of investigating syphilis epidemiology. The performance of the test to detect HIV was evaluated using 400 sera (200 HIV positives and 200 HIV negatives). Also, its performance to detect syphilis was evaluated using 85 syphilis positive and 100 syphilis negative serum samples. Individuals <15 years of age or syphilis treated or those with ≤50 cells/µL CD4 cell count were originally excluded. Outcome measures HIV screening was carried out according to the national rapid diagnostic testing (RDT) algorithm: Shenghai Kehua Bioengineering (KHB) test kit as a screening test, followed by the HIV1/2 STAT-PAK assay if positive. Where the result of the STAT-PAK is discordant with KHB, Unigold HIV is used as a tiebreaker to determine the result. We also used ELISA to resolve discordant HIV results. Syphilis serostatus was determined using the Treponema pallidum haemagglutination assay (TPHA). Results The respective sensitivity, specificity, positive predictive value and negative predictive value of the SD BIOLINE HIV/syphilis Duo test were 100, 99.5, 99.5 and 100% for HIV and 97.6, 96, 95.4 and 98% for syphilis testing, respectively. In reference to TPHA, the test kit reported 4 false positives and 2 false negative results for syphilis. The κ values were 0.99 for HIV testing and 0.94 for syphilis testing. Conclusions The excellent performance of the SD BIOLINE HIV/syphilis Duo test to detect HIV as well as syphilis facilitates the integration of syphilis testing and treatment to the already established HIV prevention programme, ultimately contributing to the dual HIV and syphilis elimination goal. PMID:25908677
Shimelis, Techalew; Tadesse, Endale
2015-04-23
To determine the diagnostic performance of the SD BIOLINE HIV/syphilis Duo rapid test. A hospital-based cross-sectional study. This evaluation was conducted at one of the largest hospitals in southern Ethiopia. Serum samples obtained from clients attending the antiretroviral therapy and voluntary counselling and testing centres were used. Sera were originally collected for the purpose of investigating syphilis epidemiology. The performance of the test to detect HIV was evaluated using 400 sera (200 HIV positives and 200 HIV negatives). Also, its performance to detect syphilis was evaluated using 85 syphilis positive and 100 syphilis negative serum samples. Individuals <15 years of age or syphilis treated or those with ≤50 cells/µL CD4 cell count were originally excluded. HIV screening was carried out according to the national rapid diagnostic testing (RDT) algorithm: Shenghai Kehua Bioengineering (KHB) test kit as a screening test, followed by the HIV1/2 STAT-PAK assay if positive. Where the result of the STAT-PAK is discordant with KHB, Unigold HIV is used as a tiebreaker to determine the result. We also used ELISA to resolve discordant HIV results. Syphilis serostatus was determined using the Treponema pallidum haemagglutination assay (TPHA). The respective sensitivity, specificity, positive predictive value and negative predictive value of the SD BIOLINE HIV/syphilis Duo test were 100, 99.5, 99.5 and 100% for HIV and 97.6, 96, 95.4 and 98% for syphilis testing, respectively. In reference to TPHA, the test kit reported 4 false positives and 2 false negative results for syphilis. The κ values were 0.99 for HIV testing and 0.94 for syphilis testing. The excellent performance of the SD BIOLINE HIV/syphilis Duo test to detect HIV as well as syphilis facilitates the integration of syphilis testing and treatment to the already established HIV prevention programme, ultimately contributing to the dual HIV and syphilis elimination goal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
A Closer Look at Self-Reported Suicide Attempts: False Positives and False Negatives
ERIC Educational Resources Information Center
Ploderl, Martin; Kralovec, Karl; Yazdi, Kurosch; Fartacek, Reinhold
2011-01-01
The validity of self-reported suicide attempt information is undermined by false positives (e.g., incidences without intent to die), or by unreported suicide attempts, referred to as false negatives. In a sample of 1,385 Austrian adults, we explored the occurrence of false positives and false negatives with detailed, probing questions. Removing…
Is it time to sound an alarm about false-positive cell-free DNA testing for fetal aneuploidy?
Mennuti, Michael T; Cherry, Athena M; Morrissette, Jennifer J D; Dugoff, Lorraine
2013-11-01
Testing cell-free DNA (cfDNA) in maternal blood samples has been shown to have very high sensitivity for the detection of fetal aneuploidy with very low false-positive results in high-risk patients who undergo invasive prenatal diagnosis. Recent observation in clinical practice of several cases of positive cfDNA tests for trisomy 18 and trisomy 13, which were not confirmed by cytogenetic testing of the pregnancy, may reflect a limitation of the positive predictive value of this quantitative testing, particularly when it is used to detect rare aneuploidies. Analysis of a larger number of false-positive cases is needed to evaluate whether these observations reflect the positive predictive value that should be expected. Infrequently, mechanisms (such as low percentage mosaicism or confined placental mosaicism) might also lead to positive cfDNA testing that is not concordant with standard prenatal cytogenetic diagnosis. The need to explore these and other possible causes of false-positive cfDNA testing is exemplified by 2 of these cases. Additional evaluation of cfDNA testing in clinical practice and a mechanism for the systematic reporting of false-positive and false-negative cases will be important before this test is offered widely to the general population of low-risk obstetric patients. In the meantime, incorporating information about the positive predictive value in pretest counseling and in clinical laboratory reports is recommended. These experiences reinforce the importance of offering invasive testing to confirm cfDNA results before parental decision-making. Copyright © 2013 Mosby, Inc. All rights reserved.
Anding, K; Albrecht, P; Heilmann, C; Daschner, F
1993-09-01
New approaches in the diagnosis of pneumonia, especially in intensive care units, are quantitative cultures of bronchoalveolar (BAL) fluid or the protected specimen brush. The sensitivity of these methods, however, has often been found to be as low as 50-60%. One possible explanation for the low sensitivity of these diagnostic tools is the antimicrobial activity of local anaesthetics used in bronchoscopy. Therefore, we investigated the bactericidal properties of oxybuprocaine, a topical anaesthetic used for bronchoscopy in our clinic, in order to test the reliability of specimens obtained from BAL. METHODS. The bactericidal activity of oxybuprocaine in concentrations of 1%, 0.1%, 0.05% and 0.01% was tested by constructing time-kill curves for Streptococcus pneumoniae, Hemophilus influenzae, Pseudomonas aeruginosa and Escherichia coli. Five stains of each bacterial species were tested. The inoculum size was 10(4) ml, and bacteria were counted after 10, 20, 30, 60 and 120 min. RESULTS. The resulting time-kill curves are demonstrated in Figs. 1-4. The most sensitive bacteria were S. pneumoniae and H. influenzae, in which significant bactericidal activity could be shown even with a 0.01% solution of oxybuprocaine. E. coli and P. aeruginosa were also inhibited, but only at the highest concentration of 1%. CONCLUSIONS. The use of local anaesthetics before material is taken for culture, e.g. from BAL, may give rise to false-negative results and should therefore be avoided or reduced. For each local anaesthetic used in bronchoscopy, the concentrations that can be used without the risk of false-negative results should be determined.
A new approach for low-cost noninvasive detection of asymptomatic heart disease at rest.
DeMarzo, Arthur P; Calvin, James E
2007-01-01
It would be useful to have an inexpensive, noninvasive point-of-care test for early detection of asymptomatic heart disease. This study used impedance cardiography (ICG) in a new way to assess heart function that did not use stroke volume or cardiac output. There is a model of the ICG dZ/dt waveform that may be used as a template to represent normal heart function. The hypothesis was that a dZ/dt waveform which deviates from that template should indicate heart dysfunction and therefore heart disease. The objective was to assess the accuracy of this new ICG approach, using echocardiography as the standard. Thirty-four outpatients undergoing echocardiographic testing were tested by ICG while sitting upright and supine. All patients had no symptoms or history of a structural or functional heart disorder. Echocardiographic testing showed 17 patients with abnormalities and 17 as normal. ICG testing yielded 16 true positives for heart dysfunction with 1 false negative (sensitivity = 94%) and 17 true negatives with no false positives (specificity = 100%). Considering that the cost, technical skill, and time required for this ICG test are comparable to those of an electrocardiograph, this new approach has potential as a point-of-care screening test for asymptomatic heart disease.
Goodman, Gail S.; Ogle, Christin M.; Block, Stephanie D.; Harris, LaTonya S.; Larson, Rakel P.; Augusti, Else-Marie; Cho, Young Il; Beber, Jonathan; Timmer, Susan; Urquiza, Anthony
2014-01-01
The purpose of the present research was to examine Deese-Roediger-McDermott (DRM) false memory for trauma-related and nontrauma-related lists in adolescents and adults with and without documented histories of child sexual abuse (CSA). Individual differences in psychopathology and adult attachment were also explored. Participants were administered free recall and recognition tests after hearing CSA, negative, neutral, and positive DRM lists. In free recall, CSA and negative lists produced the most false memory. In sharp contrast, for recognition, CSA lists enjoyed the highest d’ scores. CSA-group adolescents who evinced greater PTSD symptoms had higher rates of false memory compared to: 1) nonCSA-group adolescents with higher PTSD symptom scores (free recall), and 2) CSA-group adolescents with lower PTSD symptom scores (recognition). Regression analyses revealed that individuals with higher PTSD scores and greater fearful-avoidant attachment tendencies showed less proficient memory monitoring for CSA lists. Implications for trauma and memory development and for translational research are discussed. PMID:23786687
Small-target leak detection for a closed vessel via infrared image sequences
NASA Astrophysics Data System (ADS)
Zhao, Ling; Yang, Hongjiu
2017-03-01
This paper focus on a leak diagnosis and localization method based on infrared image sequences. Some problems on high probability of false warning and negative affect for marginal information are solved by leak detection. An experimental model is established for leak diagnosis and localization on infrared image sequences. The differential background prediction is presented to eliminate the negative affect of marginal information on test vessel based on a kernel regression method. A pipeline filter based on layering voting is designed to reduce probability of leak point false warning. A synthesize leak diagnosis and localization algorithm is proposed based on infrared image sequences. The effectiveness and potential are shown for developed techniques through experimental results.
Hillemann, D; Rüsch-Gerdes, S; Richter, E
2005-12-01
The usefulness of a low-tech rapid test for culture confirmation of Mycobacterium tuberculosis complex, Capilia TB, was tested on 172 mycobacteria-positive clinical samples. The overall sensitivity and specificity were 92.4% and 100%, respectively. In three of nine false-negative isolates a mutation in the mpb64 gene could be detected.
An evaluation of the Monosticon rapid slide test diagnosis of infectious mononucleosis
Scott, G. L.; Priest, C. J.
1972-01-01
A new rapid slide test for the detection of infectious mononucleosis heterophile antibody has been compared with the Paul-Bunnell absorption test. Out of 200 sera, 46 were seropositive for infectious mononucleosis by the Paul-Bunnell test and 43 of these were detected by the Monosticon test; the three Monosticon-negative sera were of low titre. There was no problem with false positive reactions due to heterophile antibody not specific for infectious mononucleosis. PMID:4678188
Female False Positive Exercise Stress ECG Testing - Fact Verses Fiction.
Fitzgerald, Benjamin T; Scalia, William M; Scalia, Gregory M
2018-03-07
Exercise stress testing is a well validated cardiovascular investigation. Accuracy for treadmill stress electrocardiograph (ECG) testing has been documented at 60%. False positive stress ECGs (exercise ECG changes with non-obstructive disease on anatomical testing) are common, especially in women, limiting the effectiveness of the test. This study investigates the incidence and predictors of false positive stress ECG findings, referenced against stress echocardiography (SE) as a standard. Stress echocardiography was performed using the Bruce treadmill protocol. False positive stress ECG tests were defined as greater than 1mm of ST depression on ECG during exertion, without pain, with a normal SE. Potential causes for false positive tests were recorded before the test. Three thousand consecutive negative stress echocardiograms (1036 females, 34.5%) were analysed (age 59+/-14 years. False positive (F+) stress ECGs were documented in 565/3000 tests (18.8%). F+ stress ECGs were equally prevalent in females (194/1036, 18.7%) and males (371/1964, 18.9%, p=0.85 for the difference). Potential causes (hypertension, left ventricular hypertrophy, known coronary disease, arrhythmia, diabetes mellitus, valvular heart disease) were recorded in 36/194 (18.6%) of the female F+ ECG tests and 249/371 (68.2%) of the male F+ ECG tests (p<0.0001 for the difference). These data suggest that F+ stress ECG tests are frequent and equally common in women and men. However, most F+ stress ECGs in men can be predicted before the test, while most in women cannot. Being female may be a risk factor in itself. These data reinforce the value of stress imaging, particularly in women. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.
Performance of CarbaNP and CIM tests in OXA-48 carbapenemase-producing Enterobacteriaceae.
Yıldız, Serap Süzük; Kaşkatepe, Banu; Avcıküçük, Havva; Öztürk, Şükran
2017-03-01
This study applied two phenotypic tests, namely "Carbapenemase Nordmann-Poirel" (CarbaNP) test and "Carbapenem Inactivation Method" (CIM), against the isolates carrying the carbapenem resistance genes. The study included 83 carbapenem-resistant Enterobacteriaceae isolates producing oxacillinase-48 (OXA-48) and 30 carbapenem-sensitive Enterobacteriaceae isolates. Out of the total isolates studied, 77 isolates (92.77%) were identified as Klebsiella pneumoniae and six isolates (7.23%) were identified as Escherichia coli by Matrix Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry. Polymerase chain reaction (PCR) method used to detect resistance genes found that 74 isolates (89.16%) produced OXA-48 carbapenemase, whereas nine isolates (10.84%) produced both OXA-48 and New Delhi metallo-beta-lactamase-1 (NDM-1). The isolates producing both OXA-48 and NDM-1 were found to be positive by both phenotypic tests. Among isolates carrying only bla OXA-48 gene alone, nine isolates (13.04%) for CarbaNP test and two isolates for CIM test (2.90%) displayed false negative results, respectively. The sensitivity of CarbaNP and CIM tests was found to be 89.16% and 97.59%, respectively, whereas the specificity was determined to be 100% for both tests. These findings suggest that CarbaNP and CIM tests are useful tools to identify the carbapenemase producers. Molecular methods like PCR are recommended to verify false negative tests predicted to have OXA-48 activity.
Test set readings predict clinical performance to a limited extent: preliminary findings
NASA Astrophysics Data System (ADS)
Soh, BaoLin P.; Lee, Warwick M.; Kench, Peter L.; Reed, Warren M.; McEntee, Mark F.; Brennan, Patrick C.
2013-03-01
Aim: To investigate the level of agreement between test sets and actual clinical reading Background: The performance of screen readers in detecting breast cancer is being assessed in some countries by using mammographic test sets. However, previous studies have provided little evidence that performance assessed by test sets strongly correlate to performance in clinical reading. Methods: Five clinicians from BreastScreen New South Wales participated in this study. Each clinician was asked to read 200 de-identified mammographic examinations gathered from their own case history within the BreastScreen NSW Digital Imaging Library. All test sets were designed with specific proportions of true positive, true negative, false positive and false negative examinations from the previous actual clinical reads of each reader. A prior mammogram examination for comparison (when available) was also provided for each case. Results: Preliminary analyses have shown that there is a moderate level of agreement (Kappa 0.42-0.56, p < 0.001) between laboratory test sets and actual clinical reading. In addition, a mean increase of 38% in sensitivity in the laboratory test sets as compared to their actual clinical readings was demonstrated. Specificity is similar between the laboratory test sets and actual clinical reading. Conclusion: This study demonstrated a moderate level of agreement between actual clinical reading and test set reading, which suggests that test sets have a role in reflecting clinical performance.
ERIC Educational Resources Information Center
Greyson, Bruce
2005-01-01
Some persons who claim to have had near-death experiences (NDEs) fail research criteria for having had NDEs ("false positives"); others who deny having had NDEs do meet research criteria for having had NDEs ("false negatives"). The author evaluated false positive claims and false negative denials in an organization that promotes near-death…
Reliability of the anterior drawer test, the pivot shift test, and the Lachman test.
Kim, S J; Kim, H K
1995-08-01
In 147 patients with arthroscopically proved chronic injuries of the anterior cruciate ligament, the anterior drawer test, the Lachman test, and the pivot shift test were done before operation under general or spinal anesthesia. Results of the anterior drawer test were positive in 79.6% of the patients, in 98.6% patients having the Lachman test, and in 89.8% of patients having the pivot shift test. In 19 cases (12.9%), arthroscopic examination showed reattachment of the proximally torn end of the anterior cruciate ligament to the posterior cruciate ligament. In these cases, results of the anterior drawer test were positive in 13 patients (68.4%), in 17 (89.5%) patients having the Lachman test, and in 12 patients (63.2%) having the pivot shift test. In 15 cases with a false negative pivot shift test, arthroscopy showed blockage of anterior subluxation of the lateral tibial condyle by a partially functioning portion of the anterior cruciate ligament, which was reattached to the posterior cruciate ligament in 7 cases. In 2 cases with a false negative Lachman test, there was firm reattachment of the torn end of the anterior cruciate ligament to the proximal portion of the posterior cruciate ligament combined with a bucket handle tear of the medial meniscus. The Lachman test was most sensitive in diagnosing chronic injuries of the anterior cruciate ligament. The pivot shift test was also sensitive but was influenced by many factors.
Are the memories of older adults positively biased?
Fernandes, Myra; Ross, Michael; Wiegand, Melanie; Schryer, Emily
2008-06-01
There is disagreement in the literature about whether a "positivity effect" in memory performance exists in older adults. To assess the generalizability of the effect, the authors examined memory for autobiographical, picture, and word information in a group of younger (17-29 years old) and older (60-84 years old) adults. For the autobiographical memory task, the authors asked participants to produce 4 positive, 4 negative, and 4 neutral recent autobiographical memories and to recall these a week later. For the picture and word tasks, participants studied photos or words of different valences (positive, negative, neutral) and later remembered them on a free-recall test. The authors found significant correlations in memory performance, across task material, for recall of both positive and neutral valence autobiographical events, pictures, and words. When the authors examined accurate memories, they failed to find consistent evidence, across the different types of material, of a positivity effect in either age group. However, the false memory findings offer more consistent support for a positivity effect in older adults. During recall of all 3 types of material, older participants recalled more false positive than false negative memories.
Knobloch, O; Pelz, F; Wick, U; Nelson, D L; Zoll, B
1993-03-01
In order to test whether the direct molecular diagnostic approach for fragile X mental retardation (Martin-Bell syndrome, MBS) really makes diagnosis of this disease more precise, we evaluated the results of direct diagnosis in 40 German families at risk together with the results of an earlier study with closely linked flanking markers in the same families. Of 84 men analysed, 43 showed clinical signs. In 39 of these affected men the disease could be confirmed by direct diagnosis. Compared to cytogenetic data, one man was false negative and two were false positive. Two men, whose status could not be determined by means of RFLP data, proved to be normal transmitting males (NTMs). However, the possibility of being an NTM had to be rejected in one case on RFLP data. Fragile X syndrome could be confirmed in 10 of the 13 women with clinical signs. Compared to cytogenetic data there were three cases of false negative results and one of false positive. All 36 obligate carrier women were detected by the direct approach. In addition, 22 women were newly identified as normal transmitting females (NTFs), among them one woman who could not be identified by cytogenetic means or by analysis with closely linked markers. These findings are discussed in view of the relative reliability of the three diagnostic approaches to MBS. Special attention is drawn to the significance of false negative and false positive results in direct diagnosis.
Garrison, Louis P; Babigumira, Joseph B; Masaquel, Anthony; Wang, Bruce C M; Lalla, Deepa; Brammer, Melissa
2015-06-01
Patients with breast cancer whose tumors test positive for human epidermal growth factor receptor 2 (HER2) are treated with HER2-targeted therapies such as trastuzumab, but limitations with HER2 testing may lead to false-positive (FP) or false-negative (FN) results. To develop a US-level model to estimate the effect of tumor misclassification on health care costs and patient quality-adjusted life-years (QALYs). Decision analysis was used to estimate the number of patients with early-stage breast cancer (EBC) whose HER2 status was misclassified in 2012. FP results were assumed to generate unnecessary trastuzumab costs and unnecessary cases of trastuzumab-related cardiotoxicity. FN results were assumed to save money on trastuzumab, but with a loss of QALYs and greater risk of disease recurrence and its associated costs. QALYs were valued at $100,000 under a net monetary benefit approach. Among 226,870 women diagnosed with EBC in 2012, 3.12% (n = 7,070) and 2.18% (n = 4,955) were estimated to have had FP and FN test results, respectively. Approximately 8400 QALYs (discounted, lifetime) were lost among women not receiving trastuzumab because of FN results. The estimated incremental per-patient lifetime burden of FP or FN results was $58,900 and $116,000, respectively. The implied incremental losses to society were $417 million and $575 million, respectively. HER2 tests result in misclassification and nonoptimal treatment of approximately 12,025 US patients with EBC annually. The total economic societal loss of nearly $1 billion suggests that improvements in HER2 testing accuracy are needed and that further clinical and economic studies are warranted. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Gatton, Michelle L; Ciketic, Sadmir; Barnwell, John W; Cheng, Qin; Chiodini, Peter L; Incardona, Sandra; Bell, David; Cunningham, Jane; González, Iveth J
2018-01-01
Malaria rapid diagnostic tests (RDTs) can produce false positive (FP) results in patients with human African trypanosomiasis and rheumatoid factor (RF), but specificity against other infectious agents and immunological factors is largely unknown. Low diagnostic specificity caused by cross-reactivity may lead to over-estimates of the number of malaria cases and over-use of antimalarial drugs, at the cost of not diagnosing and treating the true underlying condition. Data from the WHO Malaria RDT Product Testing Programme was analysed to assess FP rates of 221 RDTs against four infectious agents (Chagas, dengue, Leishmaniasis and Schistosomiasis) and four immunological factors (anti-nuclear antibody, human anti-mouse antibody (HAMA), RF and rapid plasma regain). Only RDTs with a FP rate against clean negative samples less than 10% were included. Paired t-tests were used to compare product-specific FP rates on clean negative samples and samples containing non-Plasmodium infectious agents and immunological factors. Forty (18%) RDTs showed no FP results against any tested infectious agent or immunological factor. In the remaining RDTs significant and clinically relevant increases in FP rates were observed for samples containing HAMA and RF (P<0.001). There were significant correlations between product-matched FP rates for RF and HAMA on all RDT test bands (P<0.001), and FP rates for each infectious agent and immunological factor were also correlated between test bands of combination RDTs (P≤0.002). False positive results against non-Plasmodium infectious agents and immunological factors does not appear to be a universal property of malaria RDTs. However, since many malaria RDTs have elevated FP rates against HAMA and RF positive samples practitioners may need to consider the possibility of false positive results for malaria in patients with conditions that stimulate HAMA or RF.
Ashikaga, Takao; Sakaguchi, Hitoshi; Sono, Sakiko; Kosaka, Nanae; Ishikawa, Makie; Nukada, Yuko; Miyazawa, Masaaki; Ito, Yuichi; Nishiyama, Naohiro; Itagaki, Hiroshi
2010-08-01
We previously developed the human cell-line activation test (h-CLAT) in vitro skin sensitisation test, based on our reported finding that a 24-hour exposure of THP-1 cells (a human monocytic leukaemia cell line) to sensitisers is sufficient to induce the augmented expression of CD86 and CD54. The aim of this study is to confirm the predictive value of h-CLAT for skin sensitisation activity by employing a larger number of test chemicals. One hundred chemicals were selected, according to their categorisation in the local lymph node assay (LLNA), as being: extreme, strong, moderate and weak sensitisers, and non-sensitisers. The correlation of the h-CLAT results with the LLNA results was 84%. There were some false negatives (e.g. benzoyl peroxide, hexyl cinnamic aldehyde) and some false positives (e.g. 1-bromobutane, diethylphthalate). Eight out of the 9 false negatives (89%) were water-insoluble chemicals. The h-CLAT could positively predict not only extreme and strong sensitisers, but also moderate and weak sensitisers, though the detection rates of weak sensitisers and non-sensitisers were comparatively low. Some sensitisers enhanced both CD86 and CD54 levels, and some enhanced the level of only one of them. The use of the combination of CD86 and CD54 induction as a positive indicator, improved the accuracy of the test. In conclusion, the h-CLAT is expected to be a useful cell-based in vitro method for predicting skin sensitisation potential. 2010 FRAME.
Radioactive phosphorus uptake test for the diagnosis of malignant melanoma of the choroid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shields, J.A.; Packer, S.
The most frequently used radioisotope in ophthalmology is radioactive phosphorus (/sup 32/P). Since its introduction into ophthalmology in 1951, it has been used primarily as an aid in the diagnosis of malignant melanoma of the choroid. During the thirty years of clinical use, the indications for this test have been clearly defined. The maximum tissue penetration of /sup 32/P is 7 mm. Surgical dissection is therefore frequently necessary to enable the ophthalmologist to place the Geiger-Muller probe on the sclera in proximity to the tumor. False positive and false negative results are unusual and the test is between 96% andmore » 100% accurate.« less
Lourenço, Felipe Rebello; Botelho, Túlia De Souza; Pinto, Terezinha De Jesus Andreoli
2012-01-01
The limulus amebocyte lysate (LAL) test is the simplest and most widely used procedure for detection of endotoxin in parenteral drugs. The LAL test demands optimal pH, ionic strength, temperature, and time of incubation. Slight changes in these parameters may increase the frequency of false-positive responses and the estimated uncertainty of the LAL test. The aim of this paper is to evaluate how changes in the pH, temperature, and time of incubation affect the occurrence of false-positive responses in the LAL test. LAL tests were performed in nominal conditions (37 °C, 60 min, and pH 7) and in different conditions of temperature (36 °C and 38 °C), time of incubation (58 and 62 min), and pH (6 and 8). Slight differences in pH increase the frequency of false-positive responses 5-fold (relative risk 5.0), resulting in an estimated of uncertainty 7.6%. Temperature and time of incubation affect the LAL test less, showing relative risks of 1.5 and 1.0, respectively. Estimated uncertainties in 36 °C or 38 °C temperatures and 58 or 62 min of incubation were found to be 2.0% and 1.0%, respectively. Simultaneous differences in these parameters significantly increase the frequency of false-positive responses. The limulus amebocyte lysate (LAL) gel-clot test is a simple test for detection of endotoxin from Gram-negative bacteria. The test is based on a gel formation when a certain amount of endotoxin is present; it is a pass/fail test. The LAL test requires optimal pH, ionic strength, temperature, and time of incubation. Slight difference in these parameters may increase the frequency of false-positive responses. The aim of this paper is to evaluate how changes in the pH, temperature, and time of incubation affect the occurrence of false-positive responses in the LAL test. We find that slight differences in pH increase the frequency of false-positive responses 5-fold. Temperature and time of incubation affect the LAL test less. Simultaneous differences in these parameters significantly increase the frequency of false-positive responses.
Reliability of Soft Tissue Model Based Implant Surgical Guides; A Methodological Mistake.
Sabour, Siamak; Dastjerdi, Elahe Vahid
2012-08-20
Abstract We were interested to read the paper by Maney P and colleagues published in the July 2012 issue of J Oral Implantol. The authors aimed to assess the reliability of soft tissue model based implant surgical guides reported that the accuracy was evaluated using software. 1 I found the manuscript title of Maney P, et al. incorrect and misleading. Moreover, they reported twenty-two sites (46.81%) were considered accurate (13 of 24 maxillary and 9 of 23 mandibular sites). As the authors point out in their conclusion, Soft tissue models do not always provide sufficient accuracy for implant surgical guide fabrication.Reliability (precision) and validity (accuracy) are two different methodological issues in researches. Sensitivity, specificity, PPV, NPV, likelihood ratio positive (true positive/false negative) and likelihood ratio negative (false positive/ true negative) as well as odds ratio (true results\\false results - preferably more than 50) are among the tests to evaluate the validity (accuracy) of a single test compared to a gold standard.2-4 It is not clear that the reported twenty-two sites (46.81%) which were considered accurate related to which of the above mentioned estimates for validity analysis. Reliability (repeatability or reproducibility) is being assessed by different statistical tests such as Pearson r, least square and paired t.test which all of them are among common mistakes in reliability analysis 5. Briefly, for quantitative variable Intra Class Correlation Coefficient (ICC) and for qualitative variables weighted kappa should be used with caution because kappa has its own limitation too. Regarding reliability or agreement, it is good to know that for computing kappa value, just concordant cells are being considered, whereas discordant cells should also be taking into account in order to reach a correct estimation of agreement (Weighted kappa).2-4 As a take home message, for reliability and validity analysis, appropriate tests should be applied.
Pennick, Kate E; McKnight, Christy A; Patterson, Jon S; Latimer, Kenneth S; Maes, Roger K; Wise, Annabel G; Kiupel, Matti
2012-03-01
Immunohistochemistry (IHC) and in situ hybridization (ISH) can be used either to detect or to differentiate between Eastern equine encephalitis virus (EEEV) and West Nile virus (WNV) within formalin-fixed, paraffin-embedded (FFPE) brain tissue of horses. To compare the diagnostic sensitivity and specificity of ISH and IHC, FFPE brain tissue from 20 EEEV-positive horses and 16 WNV-positive horses were tested with both EEEV and WNV oligoprobes and EEEV- and WNV-specific antibodies. Reverse transcription polymerase chain reaction (RT-PCR) for detection of EEEV and WNV was used as the gold standard to confirm infection. All horses that tested positive for EEEV by RT-PCR also tested positive by IHC and ISH, except for 1 case that was false-negative by ISH. In contrast, all horses that tested positive for WNV by RT-PCR tested negative by IHC and only 2 horses tested positive by ISH. No false-positives were detected with either method for both viruses. Both IHC and ISH are highly specific and sensitive diagnostic methods to detect EEEV in equine FFPE brain tissues, although neither appear effective for the diagnosis of WNV in equine neurologic cases.
Comparison of the diuretic renogram and the pressure perfusion study in children
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kass, E.J.; Majd, M.; Belman, A.B.
1985-07-01
The authors evaluated 42 hydronephrotic kidneys with diuretic renography and pressure perfusion studies to diagnose or exclude the presence of obstruction. Both studies were highly accurate but a small number of false positive and false negative studies were observed with each testing modality. The advantages, disadvantages and potential sources of inaccuracy of each study are discussed, and a protocol for the evaluation of hydronephrosis incorporating both studies is proposed.
Savic, Spasenija; Diebold, Joachim; Zimmermann, Anne-Katrin; Jochum, Wolfram; Baschiera, Betty; Grieshaber, Susanne; Tornillo, Luigi; Bisig, Bettina; Kerr, Keith; Bubendorf, Lukas
2015-08-01
Immunohistochemistry (IHC) has become a promising method for pre-screening ALK-rearrangements in non-small cell lung carcinomas (NSCLC). Various ALK antibodies, detection systems and automated immunostainers are available. We therefore aimed to compare the performance of the monoclonal 5A4 (Novocastra, Leica) and D5F3 (Cell Signaling, Ventana) antibodies using two different immunostainers. Additionally we analyzed the accuracy of prospective ALK IHC-testing in routine diagnostics. Seventy-two NSCLC with available ALK FISH results and enriched for FISH-positive carcinomas were retrospectively analyzed. IHC was performed on BenchMarkXT (Ventana) using 5A4 and D5F3, respectively, and additionally with 5A4 on Bond-MAX (Leica). Data from our routine diagnostics on prospective ALK-testing with parallel IHC, using 5A4, and FISH were available from 303 NSCLC. All three IHC protocols showed congruent results. Only 1/25 FISH-positive NSCLC (4%) was false negative by IHC. For all three IHC protocols the sensitivity, specificity, positive (PPV) and negative predictive values (NPV) compared to FISH were 96%, 100%, 100% and 97.8%, respectively. In the prospective cohort 3/32 FISH-positive (9.4%) and 2/271 FISH-negative (0.7%) NSCLC were false negative and false positive by IHC, respectively. In routine diagnostics the sensitivity, specificity, PPV and NPV of IHC compared to FISH were 90.6%, 99.3%, 93.5% and 98.9%, respectively. 5A4 and D5F3 are equally well suited for detecting ALK-rearranged NSCLC. BenchMark and BOND-MAX immunostainers can be used for IHC with 5A4. True discrepancies between IHC and FISH results do exist and need to be addressed when implementing IHC in an ALK-testing algorithm. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Franson, J.C.; Hohman, W.L.; Moore, J.L.; Smith, M.R.
1996-01-01
We used 363 blood samples collected from wild canvasback dueks (Aythya valisineria) at Catahoula Lake, Louisiana, U.S.A. to evaluate the effect of sample storage time on the efficacy of erythrocytic protoporphyrin as an indicator of lead exposure. The protoporphyrin concentration of each sample was determined by hematofluorometry within 5 min of blood collection and after refrigeration at 4 °C for 24 and 48 h. All samples were analyzed for lead by atomic absorption spectrophotometry. Based on a blood lead concentration of ≥0.2 ppm wet weight as positive evidence for lead exposure, the protoporphyrin technique resulted in overall error rates of 29%, 20%, and 19% and false negative error rates of 47%, 29% and 25% when hematofluorometric determinations were made on blood at 5 min, 24 h, and 48 h, respectively. False positive error rates were less than 10% for all three measurement times. The accuracy of the 24-h erythrocytic protoporphyrin classification of blood samples as positive or negative for lead exposure was significantly greater than the 5-min classification, but no improvement in accuracy was gained when samples were tested at 48 h. The false negative errors were probably due, at least in part, to the lag time between lead exposure and the increase of blood protoporphyrin concentrations. False negatives resulted in an underestimation of the true number of canvasbacks exposed to lead, indicating that hematofluorometry provides a conservative estimate of lead exposure.
Yamada, Kageto; Kashiwa, Machiko; Arai, Katsumi; Nagano, Noriyuki; Saito, Ryoichi
2016-09-01
We compared three screening methods for carbapenemase-producing Enterobacteriaceae. While the Modified-Hodge test and Carba NP test produced false-negative results for OXA-48-like and mucoid NDM producers, the carbapenem inactivation method (CIM) showed positive results for these isolates. Although the CIM required cultivation time, it is well suited for general clinical laboratories. Copyright © 2016 Elsevier B.V. All rights reserved.
Working memory affects false memory production for emotional events.
Mirandola, Chiara; Toffalini, Enrico; Ciriello, Alfonso; Cornoldi, Cesare
2017-01-01
Whereas a link between working memory (WM) and memory distortions has been demonstrated, its influence on emotional false memories is unclear. In two experiments, a verbal WM task and a false memory paradigm for negative, positive or neutral events were employed. In Experiment 1, we investigated individual differences in verbal WM and found that the interaction between valence and WM predicted false recognition, with negative and positive material protecting high WM individuals against false remembering; the beneficial effect of negative material disappeared in low WM participants. In Experiment 2, we lowered the WM capacity of half of the participants with a double task request, which led to an overall increase in false memories; furthermore, consistent with Experiment 1, the increase in negative false memories was larger than that of neutral or positive ones. It is concluded that WM plays a critical role in determining false memory production, specifically influencing the processing of negative material.
Helm, Rebecca K; Ceci, Stephen J; Burd, Kayla A
2016-11-01
Eyewitness identification has been shown to be fallible and prone to false memory. In this study we develop and test a new method to probe the mechanisms involved in the formation of false memories in this area, and determine whether a particular memory is likely to be true or false. We created a seven-step procedure based on the Implicit Association Test to gauge implicit biases in eyewitness identification (the IATe). We show that identification errors may result from unconscious bias caused by implicit associations evoked by a given face. We also show that implicit associations between negative attributions such as guilt and eyewitnesses' final pick from a line-up can help to distinguish between true and false memory (especially where the witness has been subject to the suggestive nature of a prior blank line-up). Specifically, the more a witness implicitly associates an individual face with a particular crime, the more likely it is that a memory they have for that person committing the crime is false. These findings are consistent with existing findings in the memory and neuroscience literature showing that false memories can be caused by implicit associations that are outside conscious awareness. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Substances that interfere with guaiac card tests: implications for gastric aspirate testing.
Gogel, H K; Tandberg, D; Strickland, R G
1989-09-01
Previous studies have shown that acidic pH and several ingestible substances can cause misleading guaiac tests of gastric aspirates. In this in vitro study, over 100 foods, beverages, and drugs were diluted to concentrations potentially present in the stomachs of outpatients being evaluated for gastrointestinal bleeding. These were mixed with known concentrations of blood and tested with different brands of guaiac cards. Decreased guaiac test sensitivity was associated with activated charcoal, dimethylaminoethanol, red chile, N-acetylcysteine, rifampin, red Jell-O (General Foods Corp, White Plains, NY), orange juice, Pepto-Bismol (Norwich Eaton Pharmaceuticals, Norwich, NY), simethicone, spaghetti sauce, and several red wines. Chlorophyll and methylene blue-containing tablets produced false-positive results, but other blue and blue-green colored tablets did not, except at high concentrations. Previously described false-negative results with vitamin C, bile, and certain antacids were confirmed, as were false-positive results with iodide, bromide, cupric sulfate, iron salts, and hypochlorite. Physicians should exercise caution when interpreting guaiac card tests of gastric aspirates, especially in the outpatient setting.
Carrera, D; de la Flor, M; Galera, J; Amillano, K; Gomez, M; Izquierdo, V; Aguilar, E; López, S; Martínez, M; Martínez, S; Serra, J M; Pérez, M; Martin, L
2016-01-01
The aim of our study was to evaluate sentinel lymph node biopsy as a diagnostic test for assessing the presence of residual metastatic axillary lymph nodes after neoadjuvant chemotherapy, replacing the need for a lymphadenectomy in negative selective lymph node biopsy patients. A multicentre, diagnostic validation study was conducted in the province of Tarragona, on women with T1-T3, N1-N2 breast cancer, who presented with a complete axillary response after neoadjuvant chemotherapy. Study procedures consisted of performing an selective lymph node biopsy followed by lymphadenectomy. A total of 53 women were included in the study. Surgical detection rate was 90.5% (no sentinel node found in 5 patients). Histopathological analysis of the lymphadenectomy showed complete disease regression of axillary nodes in 35.4% (17/48) of the patients, and residual axillary node involvement in 64.6% (31/48) of them. In lymphadenectomy positive patients, 28 had a positive selective lymph node biopsy (true positive), while 3 had a negative selective lymph node biopsy (false negative). Of the 28 true selective lymph node biopsy positives, the sentinel node was the only positive node in 10 cases. All lymphadenectomy negative cases were selective lymph node biopsy negative. These data yield a sensitivity of 93.5%, a false negative rate of 9.7%, and a global test efficiency of 93.7%. Selective lymph node biopsy after chemotherapy in patients with a complete axillary response provides valid and reliable information regarding axillary status after neoadjuvant treatment, and might prevent lymphadenectomy in cases with negative selective lymph node biopsy. Copyright © 2016 Elsevier España, S.L.U. and SEMNIM. All rights reserved.
Evaluation of Physical Examination Tests for Thumb Basal Joint Osteoarthritis
Model, Zina; Liu, Andrew Y.; Kang, Lana; Wolfe, Scott W.; Burket, Jayme C.; Lee, Steve K.
2016-01-01
Background: We compare the ability of 3 diagnostic tests to reproduce the pain of basilar joint arthritis (BJA): the grind test, the lever test (grasping the first metacarpal just distal to the basal joint and shucking back and forth in radial and ulnar directions), and the metacarpophalangeal extension test. Methods: Sixty-two patients with thumb BJA were enrolled. The 3 tests were performed in a random order on both hands of each patient. Prior to testing, patients reported their typical pain level and subsequently rated their pain after each test on a 0 to 10 scale, also specifying the extent to which the test reproduced their thumb pain (fully, partially, not at all). All patients had radiographs that displayed basal joint arthritis. A test was defined as positive for BJA if pain produced was greater than 0. Sensitivity and specificity for each test were calculated using the patients’ history of pain localized to the basal joint and BJA diagnosis on radiographs as the gold standard. Results: The lever test produced the greatest level of pain and best reproduced the presenting pain. The lever test also had the highest sensitivity, high specificity, and the lowest false-negative rate. The grind test had the lowest sensitivity, highest specificity, and highest false-negative rate. Conclusions: The lever test was the diagnostic test that best reproduced the pain caused by thumb basal joint osteoarthritis. We recommend using the lever physical examination test when evaluating the patient with suspected basal joint osteoarthritis. The often-quoted grind test is of limited diagnostic value. PMID:27418899
Tantilipikorn, Pongsakorn; Danpornprasert, Piyanart; Ngaotepprutaram, Premyot; Assanasen, Paraya; Bunnag, Chaweewan; Thinkhamrop, Bandit
2015-12-01
Diagnosis of allergic rhinitis (AR) is based on history, physical examination, and skin prick test (SPT) while intradermal (ID) test can be performed to confirm the diagnosis in case of negative result of SPT. However, the ID test is not recommended for cat and timothy grass allergy because of its high false positive rate. As a result, the "quantitative" technique of serum specific IgE (sIgE) measurement might be helpful to diagnose AR with more confidence. To evaluate the correlation between ID tests and sIgE in the diagnosis of house dust mite (HDM)-sensitive AR patients. Patients with chronic rhinitis (CR) were recruited and SPT was performed. If SPT was negative, ID test and sIgE to HDM [Dermatophagoides pteronyssinus (Dp)] measurement were performed. Eighty-two patients with chronic rhinitis (CR), whose SPTs were negative for Dp, were included. There were 39 males (47.6%) and 43 females (52.4%) aged between 18 and 76 years old (mean age = 43.3 years). The ID test was positive in 13 patients (15.9%), and was negative in 69 patients (84.1 %). sIgE to HDM was positive ( ≥ 0.35 kUA/l) in 2 patients (2.4%). There was a fair to moderate correlation between the size of wheal of ID test and sIgE to HDM (r = 0.44, 95% confidence interval: 0.19 to 0.67, p < 0.01). ID test has a fair to moderate correlation with sIgE Dermatophagoides pteronyssinus and it can be used in CR patients with negative SPT where sIgE is not feasible.
Effect of urine creatinine level during pregnancy on dipstick test.
Baba, Yosuke; Furuta, Itsuko; Zhai, Tianyue; Ohkuchi, Akihide; Yamada, Takahiro; Takahashi, Kayo; Matsubara, Shigeki; Minakami, Hisanori
2017-06-01
Dipstick results for proteinuria are affected by urine concentration, and thus urine creatinine concentration ([Cr]). This study was performed to determine whether spot urine [Cr] changes significantly during pregnancy, leading to a significantly different false-negative rate (FNR) on dipstick test between trimester. The [Cr] and protein concentrations ([P]) were analyzed in 631 spot urine samples with negative/equivocal dipstick from 425 pregnant women. False-negative dipstick was defined as [P] : [Cr] ratio (P/Cr) > 0.27 mg/mg. Median [Cr] was 117 mg/dL (range, 6.5-326 mg/dL), 72 mg/dL (range, 4.3-477 mg/dL), and 73 mg/dL (range, 8.4-396 mg/dL) in the first (n = 96), second (n = 344), and third (n = 191) trimester urine samples, respectively (P = 0.000, Kruskal-Wallis). Both [P] and P/Cr increased significantly with advancing gestation. FNR 9.4% (18/191) in the third trimester was significantly higher than that of 0.0% (0/96) in the second trimester and that of 0.5% (2/344) in the third trimester. In the 20 urine samples with false-negative dipstick, median [Cr] was 47.0 mg/dL (range, 11.0-358 mg/dL) and the proportion of samples with dilute urine, that is, [Cr] <47 mg/dL, was significantly higher than in the remaining 611 urine samples (50%, 10/20 vs 28%, 174/611, respectively, P = 0.046). Urine samples in the second and third trimesters were more likely to be diluted compared with the first trimester. This was associated with high FNR in third trimester urine samples. © 2017 Japan Society of Obstetrics and Gynecology.
Bonar, Roslyn; Favaloro, Emmanuel; Zebeljan, Diane; Rosenfeld, David; Kershaw, Geoff; Mohammed, Soma; Marsden, Katherine; Hertzberg, Mark
2012-04-01
Laboratory identification of lupus anticoagulants (LA), an important component of the clinical diagnosis of the autoimmune disorder antiphospholipid syndrome (APS), is challenged by the heterogeneity of tests available, the diagnostic and laboratory approach undertaken, and the heterogeneity of the autoantibodies present. : To assess the laboratory approach for investigation of LA, as well as the utility of various tests and test approaches, given a difficult clinical scenario in which LA might or might not be present. Ninety-three participants in the Royal College of Pathologists of Australasia (RCPA) Haematology Quality Assurance Program (QAP) were sent 4 mL of a complex but strongly positive LA sample blinded to the nature of the abnormality. Seventy-three (79%) participants returned results and in most cases diagnostic interpretations. The laboratory approach to LA investigation of this sample was quite varied: 34.7% of participants concluded the sample was LA negative, with 91.7% of these performing dilute Russell viper venom time (dRVVT) testing without mixing, whereas 43.5% of participants identified a strong LA, with 96.7% of these having performed mixing studies. Most laboratories reporting negative LA instead identified the false presence of specific factor inhibitors against a variety of factors, including II, V and VIII. For this difficult challenge, performance of non-mixing dRVVT was associated with a high false negative LA rate. (C) 2012 Royal College of Pathologists of Australasia.
[How to manage vertigo in adult?
Vuong Chaney, Hella; Rohmer, Dominique; Charpiot, Anne
2017-11-01
The interrogation and the clinical examination are critical in the research of vertigo etiology. In the context of vertigo, the vital emergencies are of neurological and vascular origins. It is therefore necessary to be able to identify them quickly and simply. Vertigo is a symptom to relieve and the cause is to be diagnosed. Careful questioning combined with neurological examination, nystagmus study, Halmagyi test and skew deviation search are more reliable than imaging in the first 48hours to detect a stroke. There are 12% false negatives in cerebral MRI and 74% false negative in cerebral CT-scan in the first 48hours of an ischemic stroke. Labyrinth emergencies are infectious labyrinthitis, perilymphatic fistula and aeroembolism of the vestibule. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Altrich, Michelle L.; Nowicki, Marek J.
2016-01-01
The identification of nearly 3,500 cases of chikungunya virus (CHIKV) infection in U.S. residents returning in 2014 and 2015 from areas in which it is endemic has raised concerns within the transplant community that, should recently infected individuals become organ and/or tissue donors, CHIKV would be transmitted to transplant recipients. Thus, tests designed to detect recent CHIKV infection among U.S. organ and tissue donors may become necessary in the future. Accordingly, we evaluated 2 enzyme-linked immunosorbent assays (ELISAs) for CHIKV IgM readily available in the United States using 1,000 deidentified serum or plasma specimens collected from donors between November 2014 and March 2015. The Euroimmun indirect ELISA identified 38 reactive specimens; however, all 38 were negative for CHIKV IgG and IgM in immunofluorescence assays (IFAs) conducted at a reference laboratory and, thus, were falsely reactive in the Euroimmun CHIKV IgM assay. The InBios IgM-capture ELISA identified 26 reactive samples, and one was still reactive (index ≥ 1.00) when retested using the InBios kit with a background subtraction modification to identify false reactivity. This reactive specimen was CHIKV IgM negative but IgG positive by IFAs at two reference laboratories; plaque reduction neutralization testing (PRNT) demonstrated CHIKV-specific reactivity. The IgG and PRNT findings strongly suggest that the InBios CHIKV IgM-reactive result represents true reactivity, even though the IgM IFA result was negative. If testing organ/tissue donors for CHIKV IgM becomes necessary, the limitations of the currently available CHIKV IgM ELISAs and options for their optimization must be understood to avoid organ/tissue wastage due to falsely reactive results. PMID:27535838
Storbeck, Justin
2013-01-01
I investigated whether negative affective states enhance encoding of and memory for item-specific information reducing false memories. Positive, negative, and neutral moods were induced, and participants then completed a Deese-Roediger-McDermott (DRM) false-memory task. List items were presented in unique spatial locations or unique fonts to serve as measures for item-specific encoding. The negative mood conditions had more accurate memories for item-specific information, and they also had fewer false memories. The final experiment used a manipulation that drew attention to distinctive information, which aided learning for DRM words, but also promoted item-specific encoding. For the condition that promoted item-specific encoding, false memories were reduced for positive and neutral mood conditions to a rate similar to that of the negative mood condition. These experiments demonstrated that negative affective cues promote item-specific processing reducing false memories. People in positive and negative moods encode events differently creating different memories for the same event.
Relations between mental verb and false belief understanding in Cantonese-speaking children.
Cheung, Him; Chen, Hsuan-Chih; Yeung, William
2009-10-01
Previous research has shown that linguistic forms that codify mental contents bear a specific relation with children's false belief understanding. These forms include mental verbs and their following complements, yet the two have not been considered separately. The current study examined the roles of mental verb semantics and the complement syntax in children's false belief understanding. Independent tasks were used to measure verb meaning, complements, and false belief understanding such that the verbs in question were present only in the verb meaning test, and no linguistic devices biased toward false belief were used in the false belief test. We focused on (a) some mental verbs that obligatorily affirm or negate what follows and (b) sentential complements, the content of which is to be evaluated against the mind of another person, not reality. Results showed that only (a) predicted false belief understanding in a group of Cantonese-speaking 4-year-olds, controlling for nonverbal intelligence and general language ability. In particular, children's understanding of the strong nonfactive semantics of the Cantonese verbs /ji5-wai4/ ("falsely think") predicted false belief understanding most strongly. The current findings suggest that false belief understanding is specifically related to the comprehension of mental verbs that entail false thought in their semantics.
Dataset for Testing Contamination Source Identification Methods for Water Distribution Networks
This dataset includes the results of a simulation study using the source inversion techniques available in the Water Security Toolkit. The data was created to test the different techniques for accuracy, specificity, false positive rate, and false negative rate. The tests examined different parameters including measurement error, modeling error, injection characteristics, time horizon, network size, and sensor placement. The water distribution system network models that were used in the study are also included in the dataset. This dataset is associated with the following publication:Seth, A., K. Klise, J. Siirola, T. Haxton , and C. Laird. Testing Contamination Source Identification Methods for Water Distribution Networks. Journal of Environmental Division, Proceedings of American Society of Civil Engineers. American Society of Civil Engineers (ASCE), Reston, VA, USA, ., (2016).
Evaluation of DuPont Qualicon Bax System PCR assay for yeast and mold.
Wallace, F Morgan; Burns, Frank; Fleck, Lois; Andaloro, Bridget; Farnum, Andrew; Tice, George; Ruebl, Joanne
2010-01-01
Evaluations were conducted to test the performance of the BAX System PCR assay which was certified as Performance Tested Method 010902 for screening yeast and mold in yogurt, corn starch, and milk-based powdered infant formula. Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent to the U.S. Food and Drug Administration's Bacteriological Analytical Manual culture method, but with a significantly shorter time to obtain results. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined affected the performance of the assay.
Feline focus: Diagnostic testing for feline thyroid disease: hypothyroidism.
Peterson, Mark E
2013-08-01
Although naturally occurring hypothyroidism is very rare in cats, iatrogenic hypothyroidism is a recognized complication of treatment for hyperthyroidism. However, confirming the diagnosis of hypothyroidism in cats is not generally straightforward. The potential for false-negative and false-positive results exists with all thyroid function tests, especially in older cats that may have concurrent nonthyroidal illness. Therefore, all thyroid function test results must be interpreted in light of the cat's history, clinical signs, and other laboratory findings. If a low to low-normal serum thyroxine (T4) value is found in a cat that has been treated for hyperthyroidism, repeating the total T4 analysis, determining free T4 and thyroid stimulating hormone (TSH) concentrations, or performing a TSH stimulation test or thyroid scintigraphy may be needed to confirm the diagnosis.
Shahi, Prinka; Sood, P B; Sharma, Arun; Madan, Manish; Shahi, Nishat; Gandhi, Geetanjali
2015-01-01
The purpose of this study was to compare the pulp testing methods (pulse oximetry and electric pulp test) in primary and young permanent teeth of children. The study included a total of 155 children aged 4 to 15 years. Twenty children formed control group I. Study group included all healthy, 85 primary 2nd molars in group II and 85 permanent 1st molars in group III. Fifty children needing endodontics treatment formed test group IV. The readings were recorded as true positive (TP), false positive (FP), true negative (TN), false negative (FN). Based on this, the sensitivity, specificity, positive predictive value and negative predictive value were calculated for each method. The results were statistically analyzed using Chi-square test. On comparing pulse oximetry with electric pulp test 'p-value' was found to be 0.487 and 1.00 for groups 1 and 2 respectively and was statistically not significant. Whereas 'p-value' for groups 3 and 4 was < 0.0001 and 0.003 respectively and was statistically highly significant. The present study indicates that pulse oximetry can be used as a routine method for assessing the pulp vitality in primary, young permanent and mature permanent teeth. How to cite this article: Shahi P, Sood PB, Sharma A, Madan M, Shahi N, Gandhi G. Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester. Int J Clin Pediatr Dent 2015;8(2):94-98.
Monticello, Thomas M; Jones, Thomas W; Dambach, Donna M; Potter, David M; Bolt, Michael W; Liu, Maggie; Keller, Douglas A; Hart, Timothy K; Kadambi, Vivek J
2017-11-01
The contribution of animal testing in drug development has been widely debated and challenged. An industry-wide nonclinical to clinical translational database was created to determine how safety assessments in animal models translate to First-In-Human clinical risk. The blinded database was composed of 182 molecules and contained animal toxicology data coupled with clinical observations from phase I human studies. Animal and clinical data were categorized by organ system and correlations determined. The 2×2 contingency table (true positive, false positive, true negative, false negative) was used for statistical analysis. Sensitivity was 48% with a 43% positive predictive value (PPV). The nonhuman primate had the strongest performance in predicting adverse effects, especially for gastrointestinal and nervous system categories. When the same target organ was identified in both the rodent and nonrodent, the PPV increased. Specificity was 84% with an 86% negative predictive value (NPV). The beagle dog had the strongest performance in predicting an absence of clinical adverse effects. If no target organ toxicity was observed in either test species, the NPV increased. While nonclinical studies can demonstrate great value in the PPV for certain species and organ categories, the NPV was the stronger predictive performance measure across test species and target organs indicating that an absence of toxicity in animal studies strongly predicts a similar outcome in the clinic. These results support the current regulatory paradigm of animal testing in supporting safe entry to clinical trials and provide context for emerging alternate models. Copyright © 2017 Elsevier Inc. All rights reserved.
Using Relative Statistics and Approximate Disease Prevalence to Compare Screening Tests.
Samuelson, Frank; Abbey, Craig
2016-11-01
Schatzkin et al. and other authors demonstrated that the ratios of some conditional statistics such as the true positive fraction are equal to the ratios of unconditional statistics, such as disease detection rates, and therefore we can calculate these ratios between two screening tests on the same population even if negative test patients are not followed with a reference procedure and the true and false negative rates are unknown. We demonstrate that this same property applies to an expected utility metric. We also demonstrate that while simple estimates of relative specificities and relative areas under ROC curves (AUC) do depend on the unknown negative rates, we can write these ratios in terms of disease prevalence, and the dependence of these ratios on a posited prevalence is often weak particularly if that prevalence is small or the performance of the two screening tests is similar. Therefore we can estimate relative specificity or AUC with little loss of accuracy, if we use an approximate value of disease prevalence.
Baugerud, Gunn Astrid; Howe, Mark L; Magnussen, Svein; Melinder, Annika
2016-03-01
Maltreated (n=26) and non-maltreated (n=31) 7- to 12-year-old children were tested on the Deese/Roediger-McDermott (DRM) false memory task using emotional and neutral word lists. True recall was significantly better for non-maltreated than maltreated children regardless of list valence. The proportion of false recall for neutral lists was comparable regardless of maltreatment status. However, maltreated children showed a significantly higher false recall rate for the emotional lists than non-maltreated children. Together, these results provide new evidence that maltreated children could be more prone to false memory illusions for negatively valenced information than their non-maltreated counterparts. Copyright © 2015 Elsevier Inc. All rights reserved.
New monoclonal antibody-based test for Helicobacter pylori urease in gastric tissue.
Kim, Do Hyun; Kim, Ho Dong; Park, Hyeuk; Choi, Seung; Beom, Jae Won; Kim, Woo Jong; Park, Chang Kook; Lee, Young Jik; Park, Ju Young; Kim, Hyung Rag; Park, Chul; Joo, Young Eun; Jung, Young Do
2016-01-01
To evaluate a new monoclonal antibody for Helicobacter pylori urease in gastric tissue. A total of 107 volunteers were enrolled. All subjects underwent a (13)C-urea breath test and esophagogastroduodenoscopy. Gastric aspirates were analyzed for pH and ammonia. Six biopsy specimens in the gastric antrum and body were obtained for a rapid urease test and histology. The new monoclonal antibody-based H. pylori urease test (HPU) was performed to rapidly and qualitatively detect urease in two biopsy specimens. H. pylori infection was diagnosed in 73 subjects. The sensitivity and specificity of the HPU was 89% and 74%, respectively. The subjects were divided into two groups: one with true-positive and true-negative HPU results (n = 90) and the other with false-positive and false-negative HPU results (n = 17). Across all subjects, ammonia levels were 900.5 ± 646.7 and 604.3 ± 594.3 μmol/L (p > 0.05), and pH was 3.37 ± 1.64 and 2.82 ± 1.51 (p > 0.05). Sensitivity was higher in the presence of atrophic gastritis or intestinal metaplasia. HPU detected H. pylori in approximately 10 min. Gastric aspirate ammonia and pH levels did not affect the test results. Sensitivity was good in the presence of atrophic gastritis or intestinal metaplasia.
Is sequencing better than phenotypic tests for the detection of pyrazinamide resistance?
Bouzouita, I; Cabibbe, A M; Trovato, A; Draoui, H; Ghariani, A; Midouni, B; Essalah, L; Mehiri, E; Cirillo, D M; Slim-Saidi, L
2018-06-01
Phenotypic tests used to detect pyrazinamide (PZA) resistance are slow and have a high rate of false resistance. To evaluate the accuracy of pncA sequencing for the detection of PZA resistance in Mycobacterium tuberculosis strains isolated in Tunisia. A total of 82 isolates, 41 resistant and 41 susceptible to PZA on BACTEC™ MGIT™ 960, were sequenced for pncA. Whole genome sequencing was performed for strains that were phenotypically resistant and had wild-type pncA in addition to MGIT retesting with a modified protocol. Twenty-three strains resistant to PZA with negative pyrazinamidase (PZase) activity harboured a mutation in the promoter or coding region of pncA. However, 18 strains resistant to PZA did not present any mutation. Repeat MGIT 960 showed that 16 of 18 M. tuberculosis isolates were falsely resistant to PZA. Compared with MGIT, PZase activity assay and pncA sequencing both presented a sensitivity of 92.0% (95%CI 73.9-99.0) and a specificity of respectively 96.5% (positive predictive value [PPV] 92.0%, negative predictive value [NPV] 96.5%) and 100.0% (PPV 100.0%, NPV 96.6%). The standard MGIT assay showed a high rate of false resistance to PZA, and the PZase activity assay is slow. pncA sequencing could therefore represent a rapid, accurate, alternative test to detect PZA resistance.
Alonso, Roberto; Pérez-García, Felipe; Gijón, Paloma; Collazos, Ana; Bouza, Emilio
2018-06-01
The Architect HIV Ag/Ab Combo Assay, a fourth-generation ELISA, has proven to be highly reliable for the diagnosis of HIV infection. However, its high sensitivity may lead to false-positive results. To evaluate the diagnostic performance of Architect in a low-prevalence population and to assess the role of the sample-to-cutoff ratio (S/CO) in reducing the frequency of false-positive results. We conducted a retrospective study of samples analyzed by Architect between January 2015 and June 2017. Positive samples were confirmed by immunoblot (RIBA) or nucleic acid amplification tests (NAATs). Different S/CO thresholds (1, 2.5, 10, 25, and 100) were analyzed to determine sensitivity, specificity, and negative and positive predictive values (NPV, PPV). ROC analysis was used to determine the optimal S/CO. A total of 69,471 samples were analyzed. 709 (1.02%) were positive by Architect. Of these, 63 (8.89%) were false-positive results. Most of them (93.65%) were in samples with S/CO < 100. However, most confirmations by NAATs (12 out of 19 cases) were also recorded for these samples. The optimal S/CO was 2.5, which provided the highest area under the ROC curve (0.9998) and no false-negative results. With this S/CO, sensitivity and specificity were 100.0%, and PPV and NPV were 95.8% and 100.0%, respectively. In addition, the frequency of false-positive results decreased significantly to 4.15%. Although Architect generates a relatively high number of false-positive results, raising the S/CO limit too much to increase specificity can lead to false-negative results, especially in newly infected individuals. Copyright © 2018 Elsevier B.V. All rights reserved.
Pan, Hui; Ba-Thein, William
2018-01-01
Global Pharma Health Fund (GPHF) Minilab™, a semi-quantitative thin-layer chromatography (TLC)-based commercially available test kit, is widely used in drug quality surveillance globally, but its diagnostic accuracy is unclear. We investigated the diagnostic accuracy of Minilab system for antimicrobials, using high-performance liquid chromatography (HPLC) as reference standard. Following the Minilab protocols and the Pharmacopoeia of the People's Republic of China protocols, Minilab-TLC and HPLC were used to test five common antimicrobials (506 batches) for relative concentration of active pharmaceutical ingredients. The prevalence of poor-quality antimicrobials determined, respectively, by Minilab TLC and HPLC was amoxicillin (0% versus 14.9%), azithromycin (0% versus 17.4%), cefuroxime axetil (14.3% versus 0%), levofloxacin (0% versus 3.0%), and metronidazole (0% versus 38.0%). The Minilab TLC had false-positive and false-negative detection rates of 2.6% (13/506) and 15.2% (77/506) accordingly, resulting in the following test characteristics: sensitivity 0%, specificity 97.0%, positive predictive value 0, negative predictive value 0.8, positive likelihood ratio 0, negative likelihood ratio 1.0, diagnostic odds ratio 0, and adjusted diagnostic odds ratio 0.2. This study demonstrates unsatisfying diagnostic accuracy of Minilab system in screening poor-quality antimicrobials of common use. Using Minilab as a stand-alone system for monitoring drug quality should be reconsidered.
Cadieux, Brigitte; Blanchfield, Burke; Smith, James P; Austin, John W
2005-05-01
A simple, rapid, cost-effective in vitro slot blot immunoassay was developed for the detection and quantification of botulinum neurotoxin type E (BoNT/E) in cultures. Culture supernatants of 36 strains of clostridia, including 12 strains of Clostridium botulinum type E, 12 strains of other C. botulinum neurotoxin serotypes, and 12 strains of other clostridial species were tested. Samples containing BoNT/E were detected using affinity-purified polyclonal rabbit antisera prepared against BoNT/E with subsequent detection of secondary antibodies using chemiluminescence. All strains of C. botulinum type E tested positive, while all non C. botulinum type E strains tested negative. The sensitivity of the slot blot immunoassay for detection of BoNT/E was approximately four mouse lethal doses (MLD). The intensity of chemiluminescence was directly correlated with the concentration of BoNT/E up to 128 MLD, allowing quantification of BoNT/E between 4 and 128 MLD. The slot blot immunoassay was compared to the mouse bioassay for detection of BoNT/E using cultures derived from fish samples inoculated with C. botulinum type E, and cultures derived from naturally contaminated environmental samples. A total of 120 primary enrichment cultures derived from fish samples, of which 103 were inoculated with C. botulinum type E, and 17 were uninoculated controls, were assayed. Of the 103 primary enrichment cultures derived from inoculated fish samples, all were positive by mouse bioassay, while 94 were also positive by slot blot immunoassay, resulting in a 7.5% false-negative rate. All 17 primary enrichment cultures derived from the uninoculated fish samples were negative by both mouse bioassay and slot blot immunoassay. A total of twenty-six primary enrichment cultures derived from environmental samples were tested by mouse bioassay and slot blot immunoassay. Of 13 primary enrichment cultures positive by mouse bioassay, 12 were also positive by slot blot immunoassay, resulting in a 3.8% false-negative rate. All 13 primary enrichment cultures that tested negative by mouse bioassay also tested negative by slot blot immunoassay. The slot blot immunoassay could be used routinely as a positive screen for BoNT/E in primary enrichment cultures, and could be used as a replacement for the mouse bioassay for pure cultures.
Grey, Katherine R; Warshaw, Erin M
Allergic contact dermatitis is an important cause of periorbital dermatitis. Topical ophthalmic agents are relevant sensitizers. Contact dermatitis to ophthalmic medications can be challenging to diagnose and manage given the numerous possible offending agents, including both active and inactive ingredients. Furthermore, a substantial body of literature reports false-negative patch test results to ophthalmic agents. Subsequently, numerous alternative testing methods have been described. This review outlines the periorbital manifestations, causative agents, and alternative testing methods of allergic contact dermatitis to ophthalmic medications.
Feline focus: Diagnostic testing for feline thyroid disease: hyperthyroidism.
Peterson, Mark E
2013-08-01
In older cats presenting with clinical features of hyperthyroidism, confirming the diagnosis of thyroid disease is usually straightforward. However, the potential for false-negative and false-positive results exists with all thyroid function tests, especially when used for routine screening of large numbers of asymptomatic cats. Therefore, all thyroid function test results must be interpreted in light of the cat's history, clinical signs, and other laboratory findings. If a high serum thyroxine (T4) value is found in a cat that lacks clinical signs of hyperthyroidism, or if hyperthyroidism is suspected in a cat with normal total T4 concentrations, repeating the total T4 analysis, determining the free T4 concentration, or performing thyroid scintigraphy may be needed to confirm the diagnosis.
Arthur, Terrance M; Bosilevac, Joseph M; Nou, Xiangwu; Koohmaraie, Mohammad
2005-08-01
Currently, several beef processors employ test-and-hold systems for increased quality control of ground beef. In such programs, each lot of product must be tested and found negative for Escherichia coli O157:H7 prior to release of the product into commerce. Optimization of three testing attributes (detection time, specificity, and sensitivity) is critical to the success of such strategies. Because ground beef is a highly perishable product, the testing methodology used must be as rapid as possible. The test also must have a low false-positive result rate so product is not needlessly discarded. False-negative results cannot be tolerated because they would allow contaminated product to be released and potentially cause disease. In this study, two culture-based and three PCR-based methods for detecting E. coli O157:H7 in ground beef were compared for their abilities to meet the above criteria. Ground beef samples were individually spiked with five genetically distinct strains of E. coli O157: H7 at concentrations of 17 and 1.7 CFU/65 g and then subjected to the various testing methodologies. There was no difference (P > 0.05) in the abilities of the PCR-based methods to detect E. coli O157:H7 inoculated in ground beef at 1.7 CFU/65 g. The culture-based systems detected more positive samples than did the PCR-based systems, but the detection times (21 to 48 h) were at least 9 h longer than those for the PCR-based methods (7.5 to 12 h). Ground beef samples were also spiked with potentially cross-reactive strains. The PCR-based systems that employed an immunomagnetic separation step prior to detection produced fewer false-positive results.
Gloria, E M; Fonseca, H; Calori-Domingues, M A; Souza, I M
1998-01-01
The results of the black light test for aflatoxin-contaminated maize carried out in a large food factory in the State of São Paulo was evaluated against bi-directional thin layer chromatography (TLC) analysis for 286 samples of maize. All 286 samples were accepted by the black light test (< 7 fluorescent points), however, the results from TLC analysis showed that 96 samples were contaminated and 14 showed aflatoxin B1 contamination levels higher than 20 micrograms/kg. There were 14 false negative results and no false positives and out of the 14 samples, six did not show visible fluorescent points. If the rejection criterion of one or more fluorescent points were applied, the six samples would be accepted by the black light test. But, in this case, 95 samples would be rejected and 87 results would be false positives because they did not have contamination levels over 20 micrograms/kg which is the acceptance limit of the black light test. The results indicate that the black light test, as utilized by this factory, was not able to indicate lots with possible contamination and the black light test, as recommended in the literature, would produce a high number of false positives. It is necessary to make more studies on the use of black light as a screening test for possible aflatoxin B1-contaminated maize.
Optimization of upcyte® human hepatocytes for the in vitro micronucleus assay.
Nörenberg, Astrid; Heinz, Stefan; Scheller, Katharina; Hewitt, Nicola J; Braspenning, Joris; Ott, Michael
2013-12-12
"Upcyte(®) human hepatocytes" have the unique property of combining proliferation with the expression of drug metabolising activities. In our current study, we evaluated whether these cells would be suitable for early in vitro micronucleus (MN) tests. A treatment period of 96 h without a recovery period was most reliable for detecting MN formation in upcyte(®) hepatocytes from Donor 740. The basal MN rate in upcyte(®) hepatocytes varied considerably between donors (7-28%); therefore, modifications to the assay medium were tested to determine whether they could decrease inherent MN formation. Optimal medium supplements were 10 ng/ml oncostatin M for the pre-culture and recovery periods and 25 ng/ml epidermal growth factor and 10 ng/ml oncostatin M for the treatment period. Using the optimised conditions and outcome criteria, the upcyte(®) hepatocyte MN assay could correctly identify directly acting (e.g. mitomycin C, etoposide) and metabolically activated genotoxins (e.g. benzo[a]pyrene, cyclophosphamide). "True negative" and "false positive" compounds were also correctly identified as negative. The basal %MN in upcyte(®) hepatocytes from Donor 740 treated with DMSO, cyclophosphamide or MMC, was essentially unaffected by the growth stage ranging from population doublings of 14-61, suggesting that billions of cells could be produced from a single donor for standardised drug toxicity testing. In conclusion, we have established and optimised an in vitro MN test by using upcyte(®) hepatocytes to correctly identify known direct and metabolically activated genotoxicants as well as "false positives" and true negative compounds. The almost unlimited supply of cells from a single donor and optimised test conditions increase reproducibility in early and more predictive in vitro MN tests. Copyright © 2013 Elsevier B.V. All rights reserved.
Avidor, Boaz; Matus, Natalia; Girshengorn, Shirley; Achsanov, Svetlana; Gielman, Simona; Zeldis, Irene; Schweitzer, Inbal; Adler, Amos; Turner, Dan
2017-08-01
HIV-1 viral load (VL) testing is important to predict viral progression and to monitor the response to antiretroviral therapy. New HIV-1 VL tests are continuously introduced to the market. Their performance is usually compared to Abbott and/or Roche HIV-1 VL assays, as reference. The Xpert HIV-1 VL test was recently introduced, but its performance compared to Roche has not been sufficiently studied. To compare the Xpert assay with Roche and to assess its use in the HIV clinical laboratory. A total of 383 plasma samples of HIV-1 infected patients previously tested by Roche, were retrospectively tested by Xpert to determine concordance between the two assays. Samples included a diversity of HIV-1 subtypes and a wide range of VLs. There was a high concordance between the two assays, except for a CRF02_AG subtype variant with high VL titters, that was detected by Roche but undetected by Xpert. The 5' long terminal repeat gene region of this virus, targeted by the Xpert assay, was amplified and sequenced. A 25 nucleotide insert was identified, but was unmatched to any known sequences of HIV-1. This particular insert, however could not explain the false-negativity by the Xpert assay. This study underlines the challenge to routine VL testing due to the high genetic diversity of HIV-1. Clinicians should, therefore be advised that a negative VL in cases where the clinical picture does not match the laboratory report, might in fact be, a false-negative result of the VL assay. Copyright © 2017 Elsevier B.V. All rights reserved.
Feedback enhances the positive effects and reduces the negative effects of multiple-choice testing.
Butler, Andrew C; Roediger, Henry L
2008-04-01
Multiple-choice tests are used frequently in higher education without much consideration of the impact this form of assessment has on learning. Multiple-choice testing enhances retention of the material tested (the testing effect); however, unlike other tests, multiple-choice can also be detrimental because it exposes students to misinformation in the form of lures. The selection of lures can lead students to acquire false knowledge (Roediger & Marsh, 2005). The present research investigated whether feedback could be used to boost the positive effects and reduce the negative effects of multiple-choice testing. Subjects studied passages and then received a multiple-choice test with immediate feedback, delayed feedback, or no feedback. In comparison with the no-feedback condition, both immediate and delayed feedback increased the proportion of correct responses and reduced the proportion of intrusions (i.e., lure responses from the initial multiple-choice test) on a delayed cued recall test. Educators should provide feedback when using multiple-choice tests.
Beynon, C M; Sumnall, H R; McVeigh, J; Cole, J C; Bellis, M A
2006-10-01
Assessment of the sensitivity and specificity of two commercially available 'drug-facilitated sexual assault' drug detector kits, Drink Guard and Drink Detective. Experimental. Laboratory. Gamma hydroxybutyrate (GHB) sodium salt, ketamine hydrochloride, temazepam, flunitrazepam and diazepam were dissolved (Tween added to benzodiazepine solutions) as separate stock solutions and added to 330 ml samples of cola (Pepsi Max), beer (Stella Artois), 'alcopop' (Bacardi Breezer) and placebo (distilled water). The doses used are reported to be common in cases of intoxication. Each kit was tested 10 times for each drink/drug combination. Two blind, independent observers scored each test (presence/absence of drug) in accordance with kit instructions; chi 2 was used to compare the proportion of times raters scored tests correctly and incorrectly. Sensitivity and specificity were calculated overall, for each drink, and sensitivity was calculated for each drug. Inter-observer agreement was evaluated using the kappa statistic. While both raters were able to score significantly more tests correctly than incorrectly using Drink Detective, and one rater scored similarly using Drink Guard, the overall sensitivity of Drink Detective and Drink Guard was 69.0% (95% CI 64.2-73.5%) and 37.5% (95% CI 30.1-45.5%), respectively. Sensitivity was drink-dependent. Drink Detective was unable to detect our dose of GHB in water, with all tests scored negatively by both raters for this drink/drug combination (n = 20 negative scores). Overall, specificity was 76.6% (95% CI 71.5-81.0%) and 87.9% (95% CI 83.0-91.6%) for Drink Guard and Drink Detective, respectively, but was affected by the beverage. Inter-rater agreement was poor for Drink Guard (kappa = 0.278 +/- 0.069) but excellent for Drink Detective (kappa = 0.894 +/- 0.245). Inter-observer agreement was drug-dependent. Use of drug detector kits by the public in the night-time environment needs further investigation and may create a false sense of security (false negatives) and undue concern (false positives) among kit users.
Supporting diagnosis of attention-deficit hyperactive disorder with novelty detection.
Lee, Hyoung-Joo; Cho, Sungzoon; Shin, Min-Sup
2008-03-01
Computerized continuous performance test (CPT) is a widely used diagnostic tool for attention-deficit hyperactivity disorder (ADHD). It measures the number of correctly detected stimuli as well as response times. Typically, when calculating a cut-off score for discriminating between normal and abnormal, only the normal children's data are collected. Then the average and standard deviation of each measure or variable is computed. If any of variables is larger than 2 sigma above the average, that child is diagnosed as abnormal. We will call this approach as "T-score 70" classifier. However, its performance has a lot to be desired due to a high false negative error. In order to improve the classification accuracy we propose to use novelty detection approaches for supporting ADHD diagnosis. Novelty detection is a model building framework where a classifier is constructed using only one class of training data and a new input pattern is classified according to its similarity to the training data. A total of eight novelty detectors are introduced and applied to our ADHD datasets collected from two modes of tests, visual and auditory. They are evaluated and compared with the T-score model on validation datasets in terms of false positive and negative error rates, and area under receiver operating characteristics curve (AuROC). Experimental results show that the cut-off score of 70 is suboptimal which leads to a low false positive error but a very high false negative error. A few novelty detectors such as Parzen density estimators yield much more balanced classification performances. Moreover, most novelty detectors outperform the T-score method for most age groups statistically with a significance level of 1% in terms of AuROC. In particular, we recommend the Parzen and Gaussian density estimators, kernel principal component analysis, one-class support vector machine, and K-means clustering novelty detector which can improve upon the T-score method on average by at least 30% for the visual test and 40% for the auditory test. In addition, their performances are relatively stable over various parameter values as long as they are within reasonable ranges. The proposed novelty detection approaches can replace the T-score method which has been considered the "gold standard" for supporting ADHD diagnosis. Furthermore, they can be applied to other psychological tests where only normal data are available.
Influence of ECG measurement accuracy on ECG diagnostic statements.
Zywietz, C; Celikag, D; Joseph, G
1996-01-01
Computer analysis of electrocardiograms (ECGs) provides a large amount of ECG measurement data, which may be used for diagnostic classification and storage in ECG databases. Until now, neither error limits for ECG measurements have been specified nor has their influence on diagnostic statements been systematically investigated. An analytical method is presented to estimate the influence of measurement errors on the accuracy of diagnostic ECG statements. Systematic (offset) errors will usually result in an increase of false positive or false negative statements since they cause a shift of the working point on the receiver operating characteristics curve. Measurement error dispersion broadens the distribution function of discriminative measurement parameters and, therefore, usually increases the overlap between discriminative parameters. This results in a flattening of the receiver operating characteristics curve and an increase of false positive and false negative classifications. The method developed has been applied to ECG conduction defect diagnoses by using the proposed International Electrotechnical Commission's interval measurement tolerance limits. These limits appear too large because more than 30% of false positive atrial conduction defect statements and 10-18% of false intraventricular conduction defect statements could be expected due to tolerated measurement errors. To assure long-term usability of ECG measurement databases, it is recommended that systems provide its error tolerance limits obtained on a defined test set.
Slawson, D C; Bennett, J H; Simon, L J; Herman, J M
1994-04-01
Clinicians who manage women with Papanicolaou (Pap) smears showing atypical squamous cells of undetermined significance (ASCUS) may miss clinically significant cervical disease by repeating the cytology alone. We evaluated the ability of the human papillomavirus (HPV) screen and the naked-eye examination after a cervical acetic acid wash to enhance the follow-up Pap smear in predicting an abnormal colposcopic biopsy. Pap smears were performed on all women (N = 7458) attending six family practice offices for a health maintenance examination from August 1989 through February 1991. Consenting subjects with ASCUS underwent repeat cytological testing, an HPV screen, and a cervical acetic acid wash examination immediately before colposcopy after a 4- to 6-month waiting period. Of the 122 consenting women identified with ASCUS, 67 (55%) demonstrated abnormalities on biopsy, including 26 with condyloma, 26 with cervical intraepithelial neoplasia I (CIN I), and 15 with CIN II to III. The false-negative rate, 58%, of the follow-up Pap smear alone for detecting these cases of condyloma and CIN was significantly decreased (false-negative rate, 27%) with the use of the cervical acetic acid wash as an adjunctive test. There was no additional reduction in the false-negative rate with the use of the HPV screen. Of the 15 subjects with high-grade cervical lesions (CIN II to III), 14 had either an abnormal follow-up Pap smear or an abnormal cervical acetic acid wash examination. Among women with cervical atypia, a single follow-up Pap smear alone failed to detect one third of the cases of high-grade disease. Ninety-three percent of these cases were detected, however, with a follow-up Pap smear and an acetic acid wash. Our one subject with a high-grade lesion missed with this combination of tests had an unsatisfactory Pap smear. Use of both tests together may reliably guide clinical decisions regarding the management of cervical atypia.
Tang, Juan; Zhou, Xiangyang; Liu, Xiaochun; Ning, Leping; Zhou, Weiya; He, Yi
2017-09-01
The aim of this study is to improve the quality of testing for glucose-6-phosphate dehydrogenase (G6PD) deficiency through evaluation and analysis of the laboratory tests for G6PD activity. External quality assessment (EQA) was carried out twice per year with five samples each from 2014 to 2016. Samples were used for quantitative and qualitative assays. Quantitative results were collected, qualitative results were determined with reference values, and information about methods, reagents and instruments from participating laboratories within the required time. Laboratory performance scores, coefficient of variation (CV), and the rates of false negative and positive results were calculated. As a result, a total of 2,834 cases of negative quality control (QC) samples and 2,451 cases of positive QC samples were assessed, where the rates of false negative and false positive results were 1.31% (37/2,834) and 1.34% (33/2,451), respectively. Quantitative results indicated an increasing trend in testing quality, which were consistent with conclusions based on the comparison of EQA full-score and acceptable ratio in six assessments. The 2nd assay in 2016 had the best full-score ratio of 68.9% (135/196) and best acceptable ratio of 84.2% (165/196). There was a decreasing trend in the average CV of six reagents produced in China, and the range of average CV increased to 14.6-23.6% in 2016. The average CV of low level and high level samples was 22.5% and 15.3%, respectively, demonstrating that samples with low G6PD activity have greater interlaboratory CV values. In conclusion, laboratories improved their testing quality and provided better diagnostic service for G6PD deficiency in areas with high incidence after participation in the EQA program in the Guangxi region.
DOT National Transportation Integrated Search
2014-08-01
In the past 5.5 years, the Texas Department of Transportation (TxDOT) spent approximately $2 million for recasting precast concrete products that had alkali-silica reaction (ASR). Aggregates belonging to false positive and negative categories based o...
Comparison of one-tier and two-tier newborn screening metrics for congenital adrenal hyperplasia.
Sarafoglou, Kyriakie; Banks, Kathryn; Gaviglio, Amy; Hietala, Amy; McCann, Mark; Thomas, William
2012-11-01
Newborn screening (NBS) for the classic forms of congenital adrenal hyperplasia (CAH) is mandated in all states in the United States. Compared with other NBS disorders, the false-positive rate (FPR) of CAH screening remains high and has not been significantly improved by adjusting 17α-hydroxyprogesterone cutoff values for birth weight and/or gestational age. Minnesota was the first state to initiate, and only 1 of 4 states currently performing, second-tier steroid profiling for CAH. False-negative rates (FNRs) for CAH are not well known. This is a population-based study of all Minnesota infants (769,834) born 1999-2009, grouped by screening protocol (one-tier with repeat screen, January 1999 to May 2004; two-tier with second-tier steroid profiling, June 2004 to December 2009). FPR, FNR, and positive predictive value (PPV) were calculated per infant, rather than per sample, and compared between protocols. Overall, 15 false-negatives (4 salt-wasting, 11 simple-virilizing) and 45 true-positives were identified from 1999 to 2009. With two-tier screening, FNR was 32%, FPR increased to 0.065%, and PPV decreased to 8%, but these changes were not statistically significant. Second-tier steroid profiling obviated repeat screens of borderline results (355 per year average). In comparing the 2 screening protocols, the FPR of CAH NBS remains high, the PPV remains low, and false-negatives occur more frequently than has been reported. Physicians should be cautioned that a negative NBS does not necessarily rule out classic CAH; therefore, any patient for whom there is clinical concern for CAH should receive immediate diagnostic testing.
Present Concepts in Internal Medicine. Volume 13, Number 1. Endocrinology Research Symposium,
1980-01-01
Liddle suppression test in which dexamethasone 0.5 mg q6h (2 mg/day) is given for two days with collection of urine 17-OHCS. 3 Confirmation of the...diagnosis is best established by measurement of urine free cortisol which has the advantage of not being elevated in obesity.4 False negatives occur in 10...experience (in the absence of conditions causing false positive responses) the presence of elevated urine free cortisol (> 100 Vg/24 h) and lack of
Experience with a tuberculosis antigen test in Rhodesia.
Cookson, J B; Cruickshank, J G; Ellis, B P
1977-10-01
Experience with a new serological method for the diagnosis of tuberculosis is reported in a predominantly black population. We have found that in only 69% of 167 patients was there agreement between serology and the presence or absence of tuberculosis. Both false positive and false negative results were common. Of 47 healthy controls, 80% were positive. These results are less satisfactory than previous studies but differences in the reading of the results seems an unlikely explanation. Differences in the populations studied may be an important factor.
Joyce, K M; McInerney, N M; Piggott, R P; Martin, F; Jones, D M; Hussey, A J; Kerin, M J; Kelly, J L; Regan, P J
2017-11-01
Sentinel lymph node biopsy (SLNB) is a standard method for determining the pathologic status of the regional lymph nodes. The aim of our study was to determine the incidence and clinicopathologic factors predictive of SLN positivity, and to evaluate the prognostic importance of SLNB in patients with cutaneous melanoma. We performed a retrospective analysis of a prospectively maintained database of all patients who underwent SLNB for primary melanoma at our institution from 2005 to 2012. Statistical analysis was performed using χ 2 and Fischer exact test. In total, 318 patients underwent SLNB, of which 65 were for thin melanoma (≤1 mm). There were 36 positive SLNB, 278 negative SLNB and in four cases the SLN was not located. The incidence rate for SLNB was 11.3% overall and 1.5% in thin melanomas alone. Statistical analysis identified Breslow thickness >1 mm (P = 0.006), Clark level ≥ IV (P = 0.004) and age <75 years (P = 0.035) as the strongest predictors of SLN positivity. Our overall false negativity rate was 20% (9/45) with one case of false-negative SLNB in thin melanomas. Breslow thickness of the primary tumour remains the strongest predictor of SLN positivity. Our findings point to a possible limited role for SLNB in thin melanoma due to its low positivity rate, associated false-negative rate and related morbidity.
A new condition for assessing the clinical efficiency of a diagnostic test.
Bokhari, Ehsan; Hubert, Lawrence
2015-09-01
When prediction using a diagnostic test outperforms simple prediction using base rates, the test is said to be "clinically efficient," a term first introduced into the literature by Meehl and Rosen (1955) in Psychological Bulletin. This article provides three equivalent conditions for determining the clinical efficiency of a diagnostic test: (a) Meehl-Rosen (Meehl & Rosen, 1955); (b) Dawes (Dawes, 1962); and (c) the Bokhari-Hubert condition, introduced here for the first time. Clinical efficiency is then generalized to situations where misclassification costs are considered unequal (for example, false negatives are more costly than false positives). As an illustration, the clinical efficiency of an actuarial device for predicting violent and dangerous behavior is examined that was developed as part of the MacArthur Violence Risk Assessment Study. (c) 2015 APA, all rights reserved.
DuPont qualicon BAX system real-time PCR assay for Escherichia coli O157:H7.
Burns, Frank; Fleck, Lois; Andaloro, Bridget; Davis, Eugene; Rohrbeck, Jeff; Tice, George; Wallace, Morgan
2011-01-01
Evaluations were conducted to test the performance of the BAX System Real-Time PCR assay, which was certified as Performance Tested Method 031002 for screening E. coli O157:H7 in ground beef, beef trim, spinach, and lettuce. Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent or superior to the FDA-BAM and the USDA-FSIS culture methods, but with a significantly shorter time to result. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined affect the performance of the assay. An accelerated shelf life study determined an initial 36 month shelf life for the test kit.
Cholli, Preetam; Bradford, Leslie; Manga, Simon; Nulah, Kathleen; Kiyang, Edith; Manjuh, Florence; DeGregorio, Geneva; Ogembo, Rebecca K; Orock, Enow; Liu, Yuxin; Wamai, Richard G; Sheldon, Lisa Kennedy; Gona, Philimon N; Sando, Zacharie; Welty, Thomas; Welty, Edith; Ogembo, Javier Gordon
2018-01-01
The World Health Organization (WHO)'s cervical cancer screening guidelines for limited-resource settings recommend sequential screening followed by same-day treatment under a "screen-and-treat" approach. We aimed to (1) assess feasibility and clinical outcomes of screening HIV-positive and HIV-negative Cameroonian women by pairing visual inspection with acetic acid and Lugol's iodine enhanced by digital cervicography (VIA/VILI-DC) with careHPV, a high-risk human papillomavirus (HR-HPV) nucleic acid test designed for low-resource settings; and (2) determine persistence of HR-HPV infection after one-year follow-up to inform optimal screening, treatment, and follow-up algorithms. We co-tested 913 previously unscreened women aged ≥30years and applied WHO-recommended treatment for all VIA/VILI-DC-positive women. Baseline prevalence of HR-HPV and HIV were 24% and 42%, respectively. On initial screen, 44 (5%) women were VIA/VILI-DC-positive, of whom 22 had HR-HPV infection, indicating 50% of women screened false-positive and would have been triaged for unnecessary same-day treatment. VIA/VILI-DC-positive women with HIV infection were three times more likely to be HR-HPV-positive than HIV-negative women (65% vs. 20%). All women positive for either VIA/VILI-DC or HR-HPV (n=245) were invited for repeat co-testing after one year, of which 136 (56%) returned for follow-up. Of 122 women who were HR-HPV-positive on initial screen, 60 (49%) re-tested negative, of whom 6 had received treatment after initial screen, indicating that 44% of initially HR-HPV-positive women spontaneously cleared infection after one year without treatment. Women with HIV were more likely to remain HR-HPV-positive on follow-up than HIV-negative women (61% vs. 22%, p<0.001). Treatment was offered to all VIA/VILI-DC positive women on initial screen, and to all women screening VIA/VILI-DC or HR-HPV positive on follow-up. We found careHPV co-testing with VIA/VILI-DC to be feasible and valuable in identifying false-positives, but careHPV screening-to-result time was too long to inform same-day treatment. Copyright © 2017 Elsevier Inc. All rights reserved.
Valence and the development of immediate and long-term false memory illusions.
Howe, Mark L; Candel, Ingrid; Otgaar, Henry; Malone, Catherine; Wimmer, Marina C
2010-01-01
Across five experiments we examined the role of valence in children's and adults' true and false memories. Using the Deese/Roediger-McDermott paradigm and either neutral or negative-emotional lists, both adults' (Experiment 1) and children's (Experiment 2) true recall and recognition was better for neutral than negative items, and although false recall was also higher for neutral items, false recognition was higher for negative items. The last three experiments examined adults' (Experiment 3) and children's (Experiments 4 and 5) 1-week long-term recognition of neutral and negative-emotional information. The results replicated the immediate recall and recognition findings from the first two experiments. More important, these experiments showed that although true recognition decreased over the 1-week interval, false recognition of neutral items remained unchanged whereas false recognition of negative-emotional items increased. These findings are discussed in terms of theories of emotion and memory as well as their forensic implications.
Van Swol, Lyn M
2008-04-01
To assess performance and processes in collective and individual memory, participants watched two job candidates on video. Beforehand, half the participants were told they would be tested on their memory of the interviews, and the other half were asked to make a decision to hire one of the candidates. Afterwards, participants completed a recognition memory task in either a group or individual condition. Groups had better recognition memory than individuals. Individuals made more false positives than false negatives and groups exaggerated this. Post-hoc analysis found that groups only exaggerated the tendency towards false positives on items that reflected negatively on the job candidate. There was no significant difference between instruction conditions. When reaching consensus on the recognition task, groups tended to choose the correct answer if at least two members had the correct answer. This method of consensus is discussed as a factor in groups' superior memory performance.
A Workflow for Identifying Metabolically Active Chemicals to Complement in vitro Toxicity Screening
The new paradigm of toxicity testing approaches involves rapid screening of thousands of chemicals across hundreds of biological targets through use of in vitro assays. Such assays may lead to false negatives when the complex metabolic processes that render a chemical bioactive i...
Tham, Jill M.; Lee, Szu Hee; Tan, Theresa M. C.; Ting, Robert C. Y.; Kara, Ursula A. K.
1999-01-01
A rapid procedure for the diagnosis of malaria infections directly from dried blood spots by PCR amplification was evaluated with samples from 52 patients. Plasmodium infections were identified with a genus-specific primer set, and species differentiation between Plasmodium falciparum and Plasmodium vivax was analyzed by multiplex PCR. The PCR test with any of the three primer sets was able to detect as few as four parasites per microliter by gel electrophoresis or by nonisotopic paper hybridization chromatography. The diagnoses obtained by PCR correlated closely with those obtained by Giemsa staining except for two samples observed to have mixed P. falciparum-P. vivax infections. These were initially missed by microscopic analysis. In comparison with antigen-capture assays for P. falciparum, the PCR assays were able to detect three infections that were missed by the ParaSight-F test. The PCR test was negative for nine ParaSight-F-positive samples and one ICT Malaria Pf-positive sample, and these were confirmed to be false-positive results. The PCR thus gave no false-negative or false-positive results. Patients undergoing antimalarial therapy were also monitored by the PCR assay. Four of seven patients who were PCR positive for P. vivax at the time of discharge were later readmitted to the hospital with a recurrence of P. vivax infection. We would like to propose that PCR is a sensitive and easy method that can serve as a useful addition to microscopy for the diagnosis and the clinical monitoring of treatment of malaria. PMID:10203469
Vahidnia, Ali; van Empel, Pieter Jan; Costa, Sandra; Oud, Rob T N; van der Straaten, Tahar; Bliekendaal, Harry; Spaargaren, Joke
2015-07-01
A 53-year-old homosexual man presented at his general practitioner (GP) practice with a suspicion of sexually transmitted infection. Initial NAAT screening was performed for Chlamydia trachomatis and Neisseria gonorrhoeae. The patient was positive for Neisseria gonorrhoeae both for his urine and rectal sample. The subsequent confirmation test for Neisseria gonorrhoeae by a second laboratory was only confirmed for the urine sample and the rectal sample was negative. We report a case of a potential false-negative diagnosis of Neisseria gonorrhoeae due to mutations of DNA sequence in the probe region of opa-MGB assay of the rectal sample. The patient did not suffer any discomfort as diagnosis of Neisseria gonorrhoeae in his urine sample had already led to treatment by prescribing the patient with Ceftriaxone 500 mg IV dissolved in 1 ml lidocaine 2% and 4 mL saline. The patient also received a prescription for Azithromycin (2x500 mg).
Multiratio fusion change detection with adaptive thresholding
NASA Astrophysics Data System (ADS)
Hytla, Patrick C.; Balster, Eric J.; Vasquez, Juan R.; Neuroth, Robert M.
2017-04-01
A ratio-based change detection method known as multiratio fusion (MRF) is proposed and tested. The MRF framework builds on other change detection components proposed in this work: dual ratio (DR) and multiratio (MR). The DR method involves two ratios coupled with adaptive thresholds to maximize detected changes and minimize false alarms. The use of two ratios is shown to outperform the single ratio case when the means of the image pairs are not equal. MR change detection builds on the DR method by including negative imagery to produce four total ratios with adaptive thresholds. Inclusion of negative imagery is shown to improve detection sensitivity and to boost detection performance in certain target and background cases. MRF further expands this concept by fusing together the ratio outputs using a routine in which detections must be verified by two or more ratios to be classified as a true changed pixel. The proposed method is tested with synthetically generated test imagery and real datasets with results compared to other methods found in the literature. DR is shown to significantly outperform the standard single ratio method. MRF produces excellent change detection results that exhibit up to a 22% performance improvement over other methods from the literature at low false-alarm rates.
Cassar, Steven; Breidenbach, Laura; Olson, Amanda; Huang, Xin; Britton, Heather; Woody, Clarissa; Sancheti, Pankajkumar; Stolarik, DeAnne; Wicke, Karsten; Hempel, Katja; LeRoy, Bruce
2017-11-01
Unanticipated effects on the central nervous system are a concern during new drug development. A larval zebrafish locomotor assay can reveal seizure liability of experimental molecules before testing in mammals. Relative absorption of compounds by larvae is lacking in prior reports of such assays; having those data may be valuable for interpreting seizure liability assay performance. Twenty-eight reference drugs were tested at multiple dose levels in fish water and analyzed by a blinded investigator. Responses of larval zebrafish were quantified during a 30min dosing period. Predictive metrics were calculated by comparing fish activity to mammalian seizure liability for each drug. Drug level analysis was performed to calculate concentrations in dose solutions and larvae. Fifteen drug candidates with neuronal targets, some having preclinical convulsion findings in mammals, were tested similarly. The assay has good predictive value of established mammalian responses for reference drugs. Analysis of drug absorption by larval fish revealed a positive correlation between hyperactive behavior and pro-convulsive drug absorption. False negative results were associated with significantly lower compound absorption compared to true negative, or true positive results. The predictive value for preclinical toxicology findings was inferior to that suggested by reference drugs. Disproportionately low exposures in larvae giving false negative results demonstrate that drug exposure analysis can help interpret results. Due to the rigorous testing commonly performed in preclinical toxicology, predicting convulsions in those studies may be more difficult than predicting effects from marketed drugs. Copyright © 2017 Elsevier Inc. All rights reserved.
Malaria rapid diagnostic test evaluation at private retail pharmacies in Kumasi, Ghana.
Audu, Rauf; Anto, Berko Panyin; Koffuor, George Asumeng; Abruquah, Akua Afriyie; Buabeng, Kwame Ohene
2016-01-01
Malaria rapid diagnostic test (MRDT) provides a good alternative to malaria microscopy diagnosis, particularly in resource-constrained settings. This study therefore evaluated MRDT in private retail pharmacies (PRPs) as a critical step in community case malaria management. In a prospective, cross-over, validation survey at six PRPs in the Ashanti Region of Ghana, 1200 patients presenting with fever in the preceding 48 h were sampled. Fingerstick blood samples were collected for preparation of thick and thin blood films for malaria microscopy. Categorized patients (600 each) went through the processes of MRDT or presumptive diagnosis (PD) of malaria. The malaria disease prevalence of the study area was established. Selectivity (Se), specificity (Sp), positive predictive value (PPV) along with false discovery rate (FDR), and negative predictive value (NPV) along with the false omission rate (FOR), and diagnostic odds ratio (DOR) of MRDT were then calculated. While 43.0% tested positive using the MRDT, 57.0% tested negative. However, 62.0% MRDT-negative patients in addition to all the MRDT positives were given artemether-lumefantrine. Of those diagnosed by PD, 98.2% were prescribed with an antimalarial (microscopy however confirmed only 70.3% as positive). Se and Sp of the MRDT were 90.68 ± 11.18% and 98.68 ± 1.19%, respectively. Malaria prevalence was estimated to be 43.3%. PPV was 98.0%, FDR was 2.0%, NPV was 98.0%, FOR was 2.0%, and DOR was 2366.43. Results highlighted good performance of MRDTs at PRPs which could inform decision toward its implementation.
An Improved Extended-Spectrum-β-Lactamase Detection Test Utilizing Aztreonam plus Clavulanate.
Thomson, Gina K; Ayaz, Maaz; Lutes, Kelli; Thomson, Kenneth S
2018-01-01
Clinical laboratories test for extended-spectrum β-lactamases (ESBLs) for epidemiological and infection control purposes and also for the potential of cephalosporins to cause therapeutic failures. Testing can be problematic, because the CLSI does not recommend the testing of all producers of ESBLs and also falsely negative results may occur with isolates that coproduce AmpC. Boronic acid-supplemented tests can enhance ESBL detection in AmpC producers. Because aztreonam inhibits AmpCs, a study was designed to compare ESBL detection by the CLSI disk test (CLSI), a boronic acid-supplemented CLSI disk test (CLSI plus BA), and an aztreonam plus clavulanate disk test (ATM plus CA). The study tested 100 well-characterized Enterobacteriaceae , Acinetobacter baumannii , and Pseudomonas aeruginosa isolates. Seventy produced TEM, SHV, or CTX-M ESBLs, with 15 coproducing an AmpC and 11 coproducing a metallo-β-lactamase. Thirty ESBL-negative isolates were also tested. Tests were inoculated by CLSI methodology and interpreted as positive if an inhibitor caused a zone diameter increase of ≥5 mm. The percentages of ESBL producers detected were as follows: ATM plus CA, 95.7%; CLSI plus BA, 88.6%; and CLSI, 78.6%. When AmpC was coproduced, the sensitivities of the tests were as follows: ATM plus CA, 100%; CLSI plus BA, 93.3%; and CLSI, 60%. ATM plus CA also detected an ESBL in 90.1% of isolates that coproduced a metallo-β-lactamase. Falsely positive tests occurred only with the CLSI and CLSI plus BA tests. Overall, the ATM plus CA test detected ESBLs more accurately than the CLSI and CLSI plus BA tests, especially with isolates coproducing an AmpC or metallo-β-lactamase. Copyright © 2017 American Society for Microbiology.
The semantics of emotion in false memory.
Brainerd, C J; Bookbinder, S H
2018-03-26
The emotional valence of target information has been a centerpiece of recent false memory research, but in most experiments, it has been confounded with emotional arousal. We sought to clarify the results of such research by identifying a shared mathematical relation between valence and arousal ratings in commonly administered normed materials. That relation was then used to (a) decide whether arousal as well as valence influences false memory when they are confounded and to (b) determine whether semantic properties that are known to affect false memory covary with valence and arousal ratings. In Study 1, we identified a quadratic relation between valence and arousal ratings of words and pictures that has 2 key properties: Arousal increases more rapidly as function of negative valence than positive valence, and hence, a given level of negative valence is more arousing than the same level of positive valence. This quadratic function predicts that if arousal as well as valence affects false memory when they are confounded, false memory data must have certain fine-grained properties. In Study 2, those properties were absent from norming data for the Cornell-Cortland Emotional Word Lists, indicating that valence but not arousal affects false memory in those norms. In Study 3, we tested fuzzy-trace theory's explanation of that pattern: that valence ratings are positively related to semantic properties that are known to increase false memory, but arousal ratings are not. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Buratto, Luciano Grüdtner; Zimmermann, Nicolle; Ferré, Perrine; Joanette, Yves; Fonseca, Rochele Paz; Stein, Lilian Milnitsky
2014-10-01
Previous research has attributed to the right hemisphere (RH) a key role in eliciting false memories to visual emotional stimuli. These results have been explained in terms of two right-hemisphere properties: (i) that emotional stimuli are preferentially processed in the RH and (ii) that visual stimuli are represented more coarsely in the RH. According to this account, false emotional memories are preferentially produced in the RH because emotional stimuli are both more strongly and more diffusely activated during encoding, leaving a memory trace that can be erroneously reactivated by similar but unstudied emotional items at test. If this right-hemisphere hypothesis is correct, then RH damage should result in a reduction in false memories to emotional stimuli relative to left-hemisphere lesions. To investigate this possibility, groups of right-brain-damaged (RBD, N=15), left-brain-damaged (LBD, N=15) and healthy (HC, N=30) participants took part in a recognition memory experiment with emotional (negative and positive) and non-emotional pictures. False memories were operationalized as incorrect responses to unstudied pictures that were similar to studied ones. Both RBD and LBD participants showed similar reductions in false memories for negative pictures relative to controls. For positive pictures, however, false memories were reduced only in RBD patients. The results provide only partial support for the right-hemisphere hypothesis and suggest that inter-hemispheric cooperation models may be necessary to fully account for false emotional memories. Copyright © 2014 Elsevier Inc. All rights reserved.
Simmons, Ann Marie; Rowneki, Mazhgan; Parmar, Heta; Cao, Yuan; Ryan, Jamie; Banada, Padmapriya P.; Deshpande, Srinidhi; Shenai, Shubhada; Gall, Alexander; Glass, Jennifer; Krieswirth, Barry; Schumacher, Samuel G.; Nabeta, Pamela; Tukvadze, Nestani; Rodrigues, Camilla; Skrahina, Alena; Tagliani, Elisa; Cirillo, Daniela M.; Davidow, Amy; Denkinger, Claudia M.; Persing, David; Kwiatkowski, Robert; Jones, Martin
2017-01-01
ABSTRACT The Xpert MTB/RIF assay (Xpert) is a rapid test for tuberculosis (TB) and rifampin resistance (RIF-R) suitable for point-of-care testing. However, it has decreased sensitivity in smear-negative sputum, and false identification of RIF-R occasionally occurs. We developed the Xpert MTB/RIF Ultra assay (Ultra) to improve performance. Ultra and Xpert limits of detection (LOD), dynamic ranges, and RIF-R rpoB mutation detection were tested on Mycobacterium tuberculosis DNA or sputum samples spiked with known numbers of M. tuberculosis H37Rv or Mycobacterium bovis BCG CFU. Frozen and prospectively collected clinical samples from patients suspected of having TB, with and without culture-confirmed TB, were also tested. For M. tuberculosis H37Rv, the LOD was 15.6 CFU/ml of sputum for Ultra versus 112.6 CFU/ml of sputum for Xpert, and for M. bovis BCG, it was 143.4 CFU/ml of sputum for Ultra versus 344 CFU/ml of sputum for Xpert. Ultra resulted in no false-positive RIF-R specimens, while Xpert resulted in two false-positive RIF-R specimens. All RIF-R-associated M. tuberculosis rpoB mutations tested were identified by Ultra. Testing on clinical sputum samples, Ultra versus Xpert, resulted in an overall sensitivity of 87.5% (95% confidence interval [CI], 82.1, 91.7) versus 81.0% (95% CI, 74.9, 86.2) and a sensitivity on sputum smear-negative samples of 78.9% (95% CI, 70.0, 86.1) versus 66.1% (95% CI, 56.4, 74.9). Both tests had a specificity of 98.7% (95% CI, 93.0, 100), and both had comparable accuracies for detection of RIF-R in these samples. Ultra should significantly improve TB detection, especially in patients with paucibacillary disease, and may provide more-reliable RIF-R detection. PMID:28851844
Junoy Montolio, Francisco G; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M
2012-10-09
To determine the influence of several factors on standard automated perimetry test results in glaucoma. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience, time of day, and season on the mean deviation (MD) was determined by performing linear regression analysis of MD against time on a series of visual fields and subsequently performing a multiple linear regression analysis with the MD residuals as dependent variable and the factors mentioned above as independent variables. Analyses were performed with and without adjustment for the test reliability (fixation losses and false-positive and false-negative answers) and with and without stratification according to disease stage (baseline MD). Mean follow-up was 9.4 years, with on average 10.8 tests per patient. Technician experience, time of day, and season were associated with the MD. Approximately 0.2 dB lower MD values were found for inexperienced technicians (P < 0.001), tests performed after lunch (P < 0.001), and tests performed in the summer or autumn (P < 0.001). The effects of time of day and season appeared to depend on disease stage. Independent of these effects, the percentage of false-positive answers strongly influenced the MD with a 1 dB increase in MD per 10% increase in false-positive answers. Technician experience, time of day, season, and the percentage of false-positive answers have a significant influence on the MD of standard automated perimetry.
Onoue, Satomi; Suzuki, Gen; Kato, Masashi; Hirota, Morihiko; Nishida, Hayato; Kitagaki, Masato; Kouzuki, Hirokazu; Yamada, Shizuo
2013-12-01
The main purpose of the present study was to establish a non-animal photosafety assessment approach for cosmetics using in vitro photochemical and photobiochemical screening systems. Fifty-one cosmetics, pharmaceutics and other chemicals were selected as model chemicals on the basis of animal and/or clinical photosafety information. The model chemicals were assessed in terms of photochemical properties by UV/VIS spectral analysis, reactive oxygen species (ROS) assay and 3T3 neutral red uptake phototoxicity testing (3T3 NRU PT). Most phototoxins exhibited potent UV/VIS absorption with molar extinction coefficients of over 1000M(-1)cm(-1), although false-negative prediction occurred for 2 cosmetic phototoxins owing to weak UV/VIS absorption. Among all the cosmetic ingredients, ca. 42% of tested chemicals were non-testable in the ROS assay because of low water solubility; thereby, micellar ROS (mROS) assay using a solubilizing surfactant was employed for follow-up screening. Upon combination use of ROS and mROS assays, the individual specificity was 88.2%, and the positive and negative predictivities were estimated to be 94.4% and 100%, respectively. In the 3T3 NRU PT, 3 cosmetics and 4 drugs were incorrectly predicted not to be phototoxic, although some of them were typical photoallergens. Thus, these in vitro screening systems individually provide false predictions; however, a systematic tiered approach using these assays could provide reliable photosafety assessment without any false-negatives. The combined use of in vitro assays might enable simple and fast non-animal photosafety evaluation of cosmetic ingredients. Copyright © 2013 Elsevier Ltd. All rights reserved.
Paige F.B. Ferguson; Michael J. Conroy; Jeffrey Hepinstall-Cymerman; Nigel Yoccoz
2015-01-01
False positive detections, such as species misidentifications, occur in ecological data, although many models do not account for them. Consequently, these models are expected to generate biased inference.The main challenge in an analysis of data with false positives is to distinguish false positive and false negative...
Xie, Gui-lin; Yin, Jun-xia; Duan, Xin-yu; Feng, Xiao-hui; Wang, Yang; Jiang, Kai; Chen, Xin-mei
2015-06-01
One hundred and fifty-nine serum samples from hydatid disease patients and 80 serum samples from patients with other liver diseases were detected by gold-immunochromatographic assay, and read by naked eyes and the gold-immunochromatographic test strip reader. The sensitivity, specificity, and accuracy of eye-based method was 92.4% (147/159), 85.0% (68/80), and 89.9% (215/239), which was lower than that of the reader detection (95.6%, 93.7%, 95.0%, respectively). While, its false negative rate (7.5%, 12/159) and false positive rate (15.0%, 12/80) was higher than that of the reader detection (4.4% and 6.3%, respectively).
A two-hypothesis approach to establishing a life detection/biohazard protocol for planetary samples
NASA Astrophysics Data System (ADS)
Conley, Catharine; Steele, Andrew
2016-07-01
The COSPAR policy on performing a biohazard assessment on samples brought from Mars to Earth is framed in the context of a concern for false-positive results. However, as noted during the 2012 Workshop for Life Detection in Samples from Mars (ref. Kminek et al., 2014), a more significant concern for planetary samples brought to Earth is false-negative results, because an undetected biohazard could increase risk to the Earth. This is the reason that stringent contamination control must be a high priority for all Category V Restricted Earth Return missions. A useful conceptual framework for addressing these concerns involves two complementary 'null' hypotheses: testing both of them, together, would allow statistical and community confidence to be developed regarding one or the other conclusion. As noted above, false negatives are of primary concern for safety of the Earth, so the 'Earth Safety null hypothesis' -- that must be disproved to assure low risk to the Earth from samples introduced by Category V Restricted Earth Return missions -- is 'There is native life in these samples.' False positives are of primary concern for Astrobiology, so the 'Astrobiology null hypothesis' -- that must be disproved in order to demonstrate the existence of extraterrestrial life is 'There is no life in these samples.' The presence of Earth contamination would render both of these hypotheses more difficult to disprove. Both these hypotheses can be tested following a strict science protocol; analyse, interprete, test the hypotheses and repeat. The science measurements undertaken are then done in an iterative fashion that responds to discovery with both hypotheses testable from interpretation of the scientific data. This is a robust, community involved activity that ensures maximum science return with minimal sample use.
Fujita, Yurika; Kasamatsu, Toshio; Ikeda, Naohiro; Nishiyama, Naohiro; Honda, Hiroshi
2016-01-15
Although in vitro chromosomal aberration tests and micronucleus tests have been widely used for genotoxicity evaluation, false-positive results have been reported under strong cytotoxic conditions. To reduce false-positive results, the new Organization for Economic Co-operation and Development (OECD) test guideline (TG) recommends the use of a new cytotoxicity index, relative increase in cell count or relative population doubling (RICC/RPD), instead of the traditionally used index, relative cell count (RCC). Although the use of the RICC/RPD may result in different outcomes and require re-evaluation of tested substances, it is impractical to re-evaluate all existing data. Therefore, we established a method to estimate test results from existing RCC data. First, we developed formulae to estimate RICC/RPD from RCC without cell counts by considering cell doubling time and experiment time. Next, the accuracy of the cytotoxicity index transformation formulae was verified by comparing estimated RICC/RPD and measured RICC/RPD for 3 major chemicals associated with false-positive genotoxicity test results: ethyl acrylate, eugenol and p-nitrophenol. Moreover, 25 compounds with false-positive in vitro chromosomal aberration (CA) test results were re-evaluated to establish a retrospective evaluation method based on derived estimated RICC/RPD values. The estimated RICC/RPD values were in good agreement with the measured RICC/RPD values for every concentration and chemical, and the estimated RICC suggested the possibility that 12 chemicals (48%) with previously judged false-positive results in fact had negative results. Our method enables transformation of RCC data into RICC/RPD values with a high degree of accuracy and will facilitate comprehensive retrospective evaluation of test results. Copyright © 2015 Elsevier B.V. All rights reserved.
Barış, Ayşe; Anlıaçık, Nur; Bulut, Mehmet Emin; Deniz, Rıdvan; Yücel, Elif; Aktaş, Elif
2017-01-01
Pharyngitis in most cases is due to viral microorganisms however drug therapy without the detection of etiological agent leads to unnecessary use of antibiotics. On the other hand, when the etiologic agent is group A beta-hemolytic streptococci (GAS) it is important to identify the etiologic agent rapidly which will guide the treatment with appropriate antibiotics. The use of highly sensitive rapid tests will contribute significantly to early diagnosis and appropriate therapy. The aim of this study is to evaluate the efficacy of Mascia Brunelli rapid antigen test for the detection of GAS in throat swab samples. A total of 833 throat swab samples submitted to our laboratory with pre-diagnosis of pharyngitis were assessed between June 2016 and August 2016. The samples were simultaneously cultured and tested by rapid Mascia Brunelli Strep-A Card (Mascia Brunelli S.p.a, Italy). For identification, bacitracin sensitivity, PYR test and latex agglutination test in addition to Bruker MALDI-TOF MS (Daltonics, Germany) system were used. The density of GAS growth in the culture was noted. The samples that were false negative with Mascia Brunelli test were re-tested with QuickVue + Strep A Test (Quidel Corporation, San Diego, USA) rapid antigen test. A total of 833 patients, 376 (45.2%) female and 457 (54.8%) male were included in the study. The age range was between 0-94 years with a mean value of 7.86 ± 6.72. 125 (15%) and 94 (11.28%) of the samples were positive with culture and rapid antigen test, respectively. Mascia Brunelli antigen test gave negative results for 31 culture positive samples. Of these 31 samples, 28 were found positive by QuickVue + Strep A antigen test. As a result, the sensitivity of the test was found to be independent of the inoculum effect. The culture positivity rate in patients between 5-15 years was 18.4%. The sensitivity, specificity, positive predictive value, negative predictive value and the accuracy of Mascia Brunelli antigen test, with respect to culture, were 75.2%, 100%, 100%, 95.81% and 96.28%, respectively. In conclusion, the selection of rapid antigen tests with high sensitivity in the diagnosis of GAS pharyngitis will contribute to the prevention of resistance development by appropriate use of antibiotics as well as early diagnosis and appropriate treatment. However, confirmation of negative rapid antigen test results by culture is very important in terms of false diagnosis and prevention of incomplete treatment.
Diagnostic accuracy of blood centers in the screening of blood donors for viral markers
Dogbe, Elliot Eli; Arthur, Fareed
2015-01-01
Introduction Blood transfusion still remains a life saving intervention in almost all healthcare facilities worldwide. Screening of blood donors/blood units is done in almost every blood bank facility before the blood units/blood components are transfused to prevent transfusion-transmissible infections. The kind of testing kits or the methods used by a facility and the technical expertise of the personnel greatly affects the screening results of a facility. This study was aimed at evaluating the diagnostic accuracy of five hospital-based blood bank testing facilities (Komfo Anokye Teaching Hospital KNUST, Kwame Nkrumah University of Science and Technology, Agogo, Bekwai and Sunyani) that used rapid immunochromatograhic assays (RIA) in screening blood donors/blood units in Ghana. Methods Blood samples (300) from the five testing facilities and their screening results for hepatitis B surface antigen (HBsAg), antibodies to hepatitis C virus (HCV) and human immunodeficiency virus (HIV) using RIAs were obtained. All the samples were then analysed for the three viral markers using 3rd generational enzyme linked immunosorbent assay (ELISA) kit as the gold standard. Results The mean false positive for HBsAg was 2.2% with Bekwai testing facility having the highest of 4.4%. For HCV, the mean false positive was 2.8% with Agogo and Bekwai testing facilities having the highest of 8.7% respectively. For HIV screening, the mean false positive was 11.1% with Bekwai testing facility having the highest of 28.0%. The mean false negative for the facilities were 3.0% for HBV, 75.0% for HCV and 0.0% for HIV with KATH having the highest of 6.3% for HBV, Bekwai having the highest of 100% for HCV and no facility showing false negative for HIV. Mean sensitivity of the screening procedure for the facilities was 97.0%, 25.0% and 100.0% whilst the mean specificity was 97.8%, 97.2% and 88.9% for HBV, HCV and HIV respectively. Statistical comparison among the testing facilities showed no significant differences among the various testing centres for HBV screening; however, significant differences were obtained for HCV and HIV screening. Conclusion This study has shown that there is no standardised screening procedure for blood bank testing facilities in the country. There is therefore an urgent need for an internal and external control body to oversee screening procedures in blood banks across the country. PMID:26090067
Whitson, Bryan A; Groth, Shawn S; Odell, David D; Briones, Eleazar P; Maddaus, Michael A; D'Cunha, Jonathan; Andrade, Rafael S
2013-05-01
Mediastinal staging in patients with non-small cell lung cancer (NSCLC) with endobronchial ultrasound-guided fine-needle aspiration (EBUS-FNA) requires a high negative predictive value (NPV) (ie, low false negative rate). We provide a conservative calculation of NPV that calls for caution in the interpretation of EBUS results. We retrospectively analyzed our prospectively gathered database (January 2007 to November 2011) to include NSCLC patients who underwent EBUS-FNA for mediastinal staging. We excluded patients with metastatic NSCLC and other malignancies. We assessed FNAs with rapid on-site evaluation (ROSE). The calculation of NPV is NPV = true negatives/true negatives + false negatives. However, this definition ignores nondiagnostic samples. Nondiagnostic samples should be added to the NPV denominator because decisions based on nondiagnostic samples could be flawed. We conservatively calculated NPV for EBUS-FNA as NPV = true negatives/true negatives + false negatives + nondiagnostic. We defined false negatives as negative FNAs but NSCLC-positive surgical biopsy of the same site. Nondiagnostic FNAs were nonrepresentative of lymphoid tissue. We compared diagnostic performance with the inclusion and exclusion of nondiagnostic procedures. We studied 120 patients with NSCLC who underwent EBUS-FNA; 5 patients had false negative findings and 10 additional patients had nondiagnostic results. The NPV with and without inclusion of nondiagnostic samples was 65.9% and 85.3%, respectively. The inclusion of nondiagnostic specimens into the conservative, worst-case-scenario calculation of NPV for EBUS-FNA in NSCLC lowers the NPV from 85.3% to 65.9%. The true NPV is likely higher than 65.9% as few nondiagnostic specimens are false negatives. Caution is imperative for the safe application of EBUS-FNA in NSCLC staging. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Chee, Y C
1983-01-01
'Total antinuclear antibody' (ANF) is detected by the fluorescent antinuclear antibody technique which is a screening test, positive in 99% of systemic lupus erythematosus (SLE) sera. The LE factor (positive in 75% of SLE sera), like the anti-DNA antibody, is an antinuclear antibody but directed against DNA-histone. ANF-negative SLE is a clinical entity with absence of these antibodies. A false negative ANF, in the presence of high titre anti-DNA antibody and/or LE cells, is illustrated in two cases of SLE. Postulated mechanisms for this phenomenon are interference in ANF detection by rheumatoid factor, and the prozone effect on the immunofluorescent tests.
Owusu, Ewurama D A; Djonor, Samson K; Brown, Charles A; Grobusch, Martin P; Mens, Petra F
2018-02-23
Plasmodium falciparum, the most dominant species in sub-Saharan Africa, causes the most severe clinical malaria manifestations. In resource-limited Ghana, where malaria and HIV geographically overlap, histidine-rich protein 2 (HRP2)-based rapid diagnostic test (RDT) is a faster, easier and cheaper alternative to clinical gold standard light microscopy. However, mutations in parasite hrp2 gene may result in missed infections, which have severe implications for malaria control. The performance of a common HRP2-based RDT and expert light microscopy in HIV-positive and HIV-negative children under 5 years old was compared with PCR as laboratory gold standard. Finger-prick capillary blood was tested with First Response ® Malaria Ag P. falciparum (HRP2). Giemsa-stained thick and thin blood films were examined with ≥ 200 high power fields and parasites counted per 200 white blood cells. Nested PCR species identification of P. falciparum was performed and resolved on agarose gel. False negatives from RDT were further tested for deleted pfhrp2/3 and flanking genes, using PCR. The study was performed in two anti-retroviral therapy clinics in Accra and Atibie. Out of 401 participants enrolled, 150 were HIV positive and 251 HIV negative. Malaria was more prevalent in children without HIV. Microscopy had a higher sensitivity [100% (99-100)] than RDT [83% (53.5-100)]. Parasites with pfhrp2/3 deletions contributed to missed infections from RDT false negatives. Circulation of malaria parasites with pfrhp2/3 deletions in this population played a role in missed infections with RDT. This ought to be addressed if further strides in malaria control are to be made.
Stürenburg, Enno; Lang, Melanie; Horstkotte, Matthias A; Laufs, Rainer; Mack, Dietrich
2004-11-01
We aimed to assess the performance of the MicroScan ESBL plus confirmation panel using a series of 87 oxyimino-cephalosporin-resistant Gram-negative bacilli of various species. Organisms tested included 57 extended-spectrum beta-lactamase (ESBL) strains comprising Enterobacter aerogenes (3), Enterobacter cloacae (10), Escherichia coli (11), Klebsiella pneumoniae (26), Klebsiella oxytoca (3) and Proteus mirabilis (4). Also included were 30 strains resistant to oxyimino cephalosporins but lacking ESBLs, which were characterized with other resistance mechanisms, such as inherent clavulanate susceptibility in Acinetobacter spp. (4), hyperproduction of AmpC enzyme in Citrobacter freundii (2), E. aerogenes (3), E. cloacae (3), E. coli (4), Hafnia alvei (1) and Morganella morganii (1), production of plasmid-mediated AmpC beta-lactamase in K. pneumoniae (3) and E. coli (3) or hyperproduction of K1 enzyme in K. oxytoca (6). The MicroScan MIC-based clavulanate synergy correctly classified 50 of 57 ESBL strains as ESBL-positive and 23 of 30 non-ESBL strains as ESBL-negative (yielding a sensitivity of 88% and a specificity of 76.7%, respectively). False negatives among ESBL producers were highest with Enterobacter spp. due to masking interactions between ESBL and AmpC beta-lactamases. False-positive classifications occurred in two Acinetobacter spp., one E. coli producing plasmid-mediated AmpC beta-lactamase and two K. oxytoca hyperproducing their chromosomal K1 beta-lactamase. The MicroScan clavulanate synergy test proved to be a valuable tool for ESBL confirmation. However, this test has limitations in detecting ESBLs in Enterobacter spp. and in discriminating ESBL-related resistance from the K1 enzyme and from inherent clavulanate susceptibility in Acinetobacter spp.
Faiella, Eliodoro; Santucci, Domiziana; Greco, Federico; Frauenfelder, Giulia; Giacobbe, Viola; Muto, Giovanni; Zobel, Bruno Beomonte; Grasso, Rosario Francesco
2018-02-01
To evaluate the diagnostic accuracy of mp-MRI correlating US/mp-MRI fusion-guided biopsy with systematic random US-guided biopsy in prostate cancer diagnosis. 137 suspected prostatic abnormalities were identified on mp-MRI (1.5T) in 96 patients and classified according to PI-RADS score v2. All target lesions underwent US/mp-MRI fusion biopsy and prostatic sampling was completed by US-guided systematic random 12-core biopsies. Histological analysis and Gleason score were established for all the samples, both target lesions defined by mp-MRI, and random biopsies. PI-RADS score was correlated with the histological results, divided in three groups (benign tissue, atypia and carcinoma) and with Gleason groups, divided in four categories considering the new Grading system of the ISUP 2014, using t test. Multivariate analysis was used to correlate PI-RADS and Gleason categories to PSA level and abnormalities axial diameter. When the random core biopsies showed carcinoma (mp-MRI false-negatives), PSA value and lesions Gleason median value were compared with those of carcinomas identified by mp-MRI (true-positives), using t test. There was statistically significant difference between PI-RADS score in carcinoma, atypia and benign lesions groups (4.41, 3.61 and 3.24, respectively) and between PI-RADS score in Gleason < 7 group and Gleason > 7 group (4.14 and 4.79, respectively). mp-MRI performance was more accurate for lesions > 15 mm and in patients with PSA > 6 ng/ml. In systematic sampling, 130 (11.25%) mp-MRI false-negative were identified. There was no statistic difference in Gleason median value (7.0 vs 7.06) between this group and the mp-MRI true-positives, but a significant lower PSA median value was demonstrated (7.08 vs 7.53 ng/ml). mp-MRI remains the imaging modality of choice to identify PCa lesions. Integrating US-guided random sampling with US/mp-MRI fusion target lesions sampling, 3.49% of false-negative were identified.
Robust Detection of Rare Species Using Environmental DNA: The Importance of Primer Specificity
Wilcox, Taylor M.; McKelvey, Kevin S.; Young, Michael K.; Jane, Stephen F.; Lowe, Winsor H.; Whiteley, Andrew R.; Schwartz, Michael K.
2013-01-01
Environmental DNA (eDNA) is being rapidly adopted as a tool to detect rare animals. Quantitative PCR (qPCR) using probe-based chemistries may represent a particularly powerful tool because of the method’s sensitivity, specificity, and potential to quantify target DNA. However, there has been little work understanding the performance of these assays in the presence of closely related, sympatric taxa. If related species cause any cross-amplification or interference, false positives and negatives may be generated. These errors can be disastrous if false positives lead to overestimate the abundance of an endangered species or if false negatives prevent detection of an invasive species. In this study we test factors that influence the specificity and sensitivity of TaqMan MGB assays using co-occurring, closely related brook trout (Salvelinus fontinalis) and bull trout (S. confluentus) as a case study. We found qPCR to be substantially more sensitive than traditional PCR, with a high probability of detection at concentrations as low as 0.5 target copies/µl. We also found that number and placement of base pair mismatches between the Taqman MGB assay and non-target templates was important to target specificity, and that specificity was most influenced by base pair mismatches in the primers, rather than in the probe. We found that insufficient specificity can result in both false positive and false negative results, particularly in the presence of abundant related species. Our results highlight the utility of qPCR as a highly sensitive eDNA tool, and underscore the importance of careful assay design. PMID:23555689
Robust detection of rare species using environmental DNA: the importance of primer specificity.
Wilcox, Taylor M; McKelvey, Kevin S; Young, Michael K; Jane, Stephen F; Lowe, Winsor H; Whiteley, Andrew R; Schwartz, Michael K
2013-01-01
Environmental DNA (eDNA) is being rapidly adopted as a tool to detect rare animals. Quantitative PCR (qPCR) using probe-based chemistries may represent a particularly powerful tool because of the method's sensitivity, specificity, and potential to quantify target DNA. However, there has been little work understanding the performance of these assays in the presence of closely related, sympatric taxa. If related species cause any cross-amplification or interference, false positives and negatives may be generated. These errors can be disastrous if false positives lead to overestimate the abundance of an endangered species or if false negatives prevent detection of an invasive species. In this study we test factors that influence the specificity and sensitivity of TaqMan MGB assays using co-occurring, closely related brook trout (Salvelinus fontinalis) and bull trout (S. confluentus) as a case study. We found qPCR to be substantially more sensitive than traditional PCR, with a high probability of detection at concentrations as low as 0.5 target copies/µl. We also found that number and placement of base pair mismatches between the Taqman MGB assay and non-target templates was important to target specificity, and that specificity was most influenced by base pair mismatches in the primers, rather than in the probe. We found that insufficient specificity can result in both false positive and false negative results, particularly in the presence of abundant related species. Our results highlight the utility of qPCR as a highly sensitive eDNA tool, and underscore the importance of careful assay design.
Impaired theory of mind for moral judgment in high-functioning autism.
Moran, Joseph M; Young, Liane L; Saxe, Rebecca; Lee, Su Mei; O'Young, Daniel; Mavros, Penelope L; Gabrieli, John D
2011-02-15
High-functioning autism (ASD) is characterized by real-life difficulties in social interaction; however, these individuals often succeed on laboratory tests that require an understanding of another person's beliefs and intentions. This paradox suggests a theory of mind (ToM) deficit in adults with ASD that has yet to be demonstrated in an experimental task eliciting ToM judgments. We tested whether ASD adults would show atypical moral judgments when they need to consider both the intentions (based on ToM) and outcomes of a person's actions. In experiment 1, ASD and neurotypical (NT) participants performed a ToM task designed to test false belief understanding. In experiment 2, the same ASD participants and a new group of NT participants judged the moral permissibility of actions, in a 2 (intention: neutral/negative) × 2 (outcome: neutral/negative) design. Though there was no difference between groups on the false belief task, there was a selective difference in the moral judgment task for judgments of accidental harms, but not neutral acts, attempted harms, or intentional harms. Unlike the NT group, which judged accidental harms less morally wrong than attempted harms, the ASD group did not reliably judge accidental and attempted harms as morally different. In judging accidental harms, ASD participants appeared to show an underreliance on information about a person's innocent intention and, as a direct result, an overreliance on the action's negative outcome. These findings reveal impairments in integrating mental state information (e.g., beliefs, intentions) for moral judgment.
Clinical outcome of subchromosomal events detected by whole‐genome noninvasive prenatal testing
Helgeson, J.; Wardrop, J.; Boomer, T.; Almasri, E.; Paxton, W. B.; Saldivar, J. S.; Dharajiya, N.; Monroe, T. J.; Farkas, D. H.; Grosu, D. S.
2015-01-01
Abstract Objective A novel algorithm to identify fetal microdeletion events in maternal plasma has been developed and used in clinical laboratory‐based noninvasive prenatal testing. We used this approach to identify the subchromosomal events 5pdel, 22q11del, 15qdel, 1p36del, 4pdel, 11qdel, and 8qdel in routine testing. We describe the clinical outcomes of those samples identified with these subchromosomal events. Methods Blood samples from high‐risk pregnant women submitted for noninvasive prenatal testing were analyzed using low coverage whole genome massively parallel sequencing. Sequencing data were analyzed using a novel algorithm to detect trisomies and microdeletions. Results In testing 175 393 samples, 55 subchromosomal deletions were reported. The overall positive predictive value for each subchromosomal aberration ranged from 60% to 100% for cases with diagnostic and clinical follow‐up information. The total false positive rate was 0.0017% for confirmed false positives results; false negative rate and sensitivity were not conclusively determined. Conclusion Noninvasive testing can be expanded into the detection of subchromosomal copy number variations, while maintaining overall high test specificity. In the current setting, our results demonstrate high positive predictive values for testing of rare subchromosomal deletions. © 2015 The Authors. Prenatal Diagnosis published by John Wiley & Sons Ltd. PMID:26088833
Testing the validity of a continuous false belief task in 3- to 7-year-old children.
Mahy, Caitlin E V; Bernstein, Daniel M; Gerrard, Lindsey D; Atance, Cristina M
2017-08-01
In two studies, we examined young children's performance on the paper-and-pencil version of the Sandbox task, a continuous measure of false belief, and its relations with other false belief and inhibition tasks. In Study 1, 96 children aged 3 to 7years completed three false belief tasks (Sandbox, Unexpected Contents, and Appearance/Reality) and two inhibition tasks (Head-Shoulders-Knees-Toes and Grass/Snow). Results revealed that false belief bias-a measure of egocentrism-on the Sandbox task correlated with age but not with the Unexpected Contents or Appearance/Reality task or with measures of inhibition after controlling for age. In Study 2, 90 3- to 7-year-olds completed five false belief tasks (Sandbox, Unexpected Contents, Appearance/Reality, Change of Location, and a second-order false belief task), two inhibition tasks (Simon Says and Grass/Snow), and a receptive vocabulary task (Peabody Picture Vocabulary Test). Results showed that false belief bias on the Sandbox task correlated negatively with age and with the Change of Location task but not with the other false belief or inhibition tasks after controlling for age and receptive vocabulary. The Sandbox task shows promise as an age-sensitive measure of false belief performance during early childhood and shows convergent and discriminant validity. Copyright © 2017 Elsevier Inc. All rights reserved.
How does negative emotion cause false memories?
Brainerd, C J; Stein, L M; Silveira, R A; Rohenkohl, G; Reyna, V F
2008-09-01
Remembering negative events can stimulate high levels of false memory, relative to remembering neutral events. In experiments in which the emotional valence of encoded materials was manipulated with their arousal levels controlled, valence produced a continuum of memory falsification. Falsification was highest for negative materials, intermediate for neutral materials, and lowest for positive materials. Conjoint-recognition analysis produced a simple process-level explanation: As one progresses from positive to neutral to negative valence, false memory increases because (a) the perceived meaning resemblance between false and true items increases and (b) subjects are less able to use verbatim memories of true items to suppress errors.
Variation in aluminium patch test reactivity over time.
Siemund, Ingrid; Mowitz, Martin; Zimerson, Erik; Bruze, Magnus; Hindsén, Monica
2017-11-01
Contact allergy to aluminium has been reported more frequently in recent years. It has been pointed out that positive patch test reactions to aluminium may not be reproducible on retesting. To investigate possible variations in patch test reactivity to aluminium over time. Twenty-one adults, who had previously reacted positively to aluminium, were patch tested with equimolar dilution series in pet. of aluminium chloride hexahydrate and aluminium lactate, four times over a period of 8 months. Thirty-six of 84 (43%) serial dilution tests with aluminium chloride hexahydrate and 49 of 84 (58%) serial dilution tests with aluminium lactate gave negative results. The range of reactivity varied between a negative reaction to aluminium chloride hexahydrate at 10% and/or to aluminium lactate at 12%, and a positive reaction to aluminium chloride hexahydrate at 0.1% and/or to aluminium lactate at 0.12%. The highest individual difference in test reactivity noticed was 320-fold when the two most divergent minimal eliciting concentrations were compared. The patch test reactivity to aluminium varies over time. Aluminium-allergic individuals may have false-negative reactions. Therefore, retesting with aluminium should be considered when there is a strong suspicion of aluminium contact allergy. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Kiemde, Francois; Bonko, Massa Dit Achille; Tahita, Marc Christian; Lompo, Palpouguini; Rouamba, Toussaint; Tinto, Halidou; van Hensbroek, Michael Boele; Mens, Petra F; Schallig, Henk D F H
2017-07-20
It remains challenging to distinguish malaria from other fever causing infections, as a positive rapid diagnostic test does not always signify a true active malaria infection. This study was designed to determine the influence of other causes of fever, prior anti-malarial treatment, and a possible seasonality of the performance of a PfHRP2 RDT for the diagnosis of malaria in children under-5 years of age living in a malaria endemic area. A prospective etiology study was conducted in 2015 among febrile children under 5 years of age in Burkina Faso. In order to assess the influence of other febrile illnesses, prior treatment and seasonality on the performance of a PfHRP2 RDT in diagnosing malaria, the RDT results were compared with the gold standard (expert microscopic diagnosis of Plasmodium falciparum) and test results were analysed by assuming that prior anti-malarial use and bacterial/viral infection status would have been known prior to testing. To assess bacterial and viral infection status blood, urine and stool samples were analysed. In total 683 blood samples were analysed with microscopy and RDT-PfHRP2. Plasmodium falciparum malaria was diagnosed in 49.8% (340/683) by microscopy compared to 69.5% (475/683) by RDT-PfHRP2. The RDT-PfHRP2 reported 29.7% (141/475) false positive results and 1.8% (6/340) false negative cases. The RDT-PfHRP2 had a high sensitivity (98.2%) and negative predictive value (97.1%), but a low specificity (58.9%) and positive predictive value (70.3%). Almost 50% of the alternative cause of fever were diagnosed by laboratory testing in the RDT false positive malaria group. The use of a malaria RDT-PfHRP2 in a malaria endemic area may cause misdiagnosis of the actual cause of fever due to false positive test results. The development of a practical diagnostic tool to screen for other causes of fever in malaria endemic areas is required to save lives.
Possible Correlation of Transfusion Transmitted Diseases with Rh type and ABO Blood Group System
Tyagi, Surabhi; Tyagi, Alok
2013-01-01
Background: Screening of blood is mandatory for transfusion transmitted diseases and is routinely done in the blood banks. As blood is the major source transmission of hepatitis B, hepatitis C, human immunodeficiency virus & many other diseases the hazards can be minimised by effective donor selection and screening. Aim: To find out the correlation between the transfusion transmitted diseases and blood groups and the seroprevalence of HIV, HBV, HCV & syphilis among the apparently healthy human blood donors. Study, Setting & Design: This retrospective study was conducted at the blood bank of a tertiary health care teaching centre for a period of four years. Material and Methods: All voluntary and replacement donors reporting to the blood bank were screened for HIV-1 & 2, HBsAg, HCV and Syphilis. Anti–HIV -1 & 2, HBsAg & anti - HCV was tested using the appropriate Enzyme–linked immunosorbent assay (ELISA) technique using micro–elisa kit supplied by J.Mitra & Co.Ltd. The seropositive samples were again tested on ELISA kits of RFCL &/or BIORAD for further confirmation & ruling out any false positive or false negative results. The rapid plasma reagain (RPR) test was used for estimation of syphilis infection. Statistical Analysis: The data entry was carried out using Microsoft office excel worksheet and was analysed by percentage and comparison. Results: Total of 6000 donors were screened which included voluntary and replacement donors. Seroprevalence of HIV (0.1833 %), HCV (1.28%), HBsAg (1.5833 %) and syphilis (0.4333 %) was detected. In the study done it was also noted - that the NEGATIVE blood groups were more prone to TTIs. Blood group A negative was more prone to TTIs with HIV, HBsAg and VDRL while blood group B negative was more affected by HCV. Conclusion: Seroprevalence of these infections shows that routine screening is a must for blood and blood product safe transfusion. Do negative blood groups predispose to TTIs? A finding which makes us think…. PMID:24179900
Possible Correlation of Transfusion Transmitted Diseases with Rh type and ABO Blood Group System.
Tyagi, Surabhi; Tyagi, Alok
2013-09-01
Screening of blood is mandatory for transfusion transmitted diseases and is routinely done in the blood banks. As blood is the major source transmission of hepatitis B, hepatitis C, human immunodeficiency virus & many other diseases the hazards can be minimised by effective donor selection and screening. To find out the correlation between the transfusion transmitted diseases and blood groups and the seroprevalence of HIV, HBV, HCV & syphilis among the apparently healthy human blood donors. Study, Setting & Design: This retrospective study was conducted at the blood bank of a tertiary health care teaching centre for a period of four years. All voluntary and replacement donors reporting to the blood bank were screened for HIV-1 & 2, HBsAg, HCV and Syphilis. Anti-HIV -1 & 2, HBsAg & anti - HCV was tested using the appropriate Enzyme-linked immunosorbent assay (ELISA) technique using micro-elisa kit supplied by J.Mitra & Co.Ltd. The seropositive samples were again tested on ELISA kits of RFCL &/or BIORAD for further confirmation & ruling out any false positive or false negative results. The rapid plasma reagain (RPR) test was used for estimation of syphilis infection. The data entry was carried out using Microsoft office excel worksheet and was analysed by percentage and comparison. Total of 6000 donors were screened which included voluntary and replacement donors. Seroprevalence of HIV (0.1833 %), HCV (1.28%), HBsAg (1.5833 %) and syphilis (0.4333 %) was detected. In the study done it was also noted - that the NEGATIVE blood groups were more prone to TTIs. Blood group A negative was more prone to TTIs with HIV, HBsAg and VDRL while blood group B negative was more affected by HCV. Seroprevalence of these infections shows that routine screening is a must for blood and blood product safe transfusion. Do negative blood groups predispose to TTIs? A finding which makes us think….
Bruner, L H; Carr, G J; Harbell, J W; Curren, R D
2002-06-01
An approach commonly used to measure new toxicity test method (NTM) performance in validation studies is to divide toxicity results into positive and negative classifications, and the identify true positive (TP), true negative (TN), false positive (FP) and false negative (FN) results. After this step is completed, the contingent probability statistics (CPS), sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) are calculated. Although these statistics are widely used and often the only statistics used to assess the performance of toxicity test methods, there is little specific guidance in the validation literature on what values for these statistics indicate adequate performance. The purpose of this study was to begin developing data-based answers to this question by characterizing the CPS obtained from an NTM whose data have a completely random association with a reference test method (RTM). Determining the CPS of this worst-case scenario is useful because it provides a lower baseline from which the performance of an NTM can be judged in future validation studies. It also provides an indication of relationships in the CPS that help identify random or near-random relationships in the data. The results from this study of randomly associated tests show that the values obtained for the statistics vary significantly depending on the cut-offs chosen, that high values can be obtained for individual statistics, and that the different measures cannot be considered independently when evaluating the performance of an NTM. When the association between results of an NTM and RTM is random the sum of the complementary pairs of statistics (sensitivity + specificity, NPV + PPV) is approximately 1, and the prevalence (i.e., the proportion of toxic chemicals in the population of chemicals) and PPV are equal. Given that combinations of high sensitivity-low specificity or low specificity-high sensitivity (i.e., the sum of the sensitivity and specificity equal to approximately 1) indicate lack of predictive capacity, an NTM having these performance characteristics should be considered no better for predicting toxicity than by chance alone.
Corson-Knowles, Daniel; Russell, Frances M
2018-05-01
Clinical ultrasound (CUS) is highly specific for the diagnosis of acute appendicitis but is operator-dependent. The goal of this study was to determine if a heterogeneous group of emergency physicians (EP) could diagnose acute appendicitis on CUS in patients with a moderate to high pre-test probability. This was a prospective, observational study of a convenience sample of adult and pediatric patients with suspected appendicitis. Sonographers received a structured, 20-minute CUS training on appendicitis prior to patient enrollment. The presence of a dilated (>6 mm diameter), non-compressible, blind-ending tubular structure was considered a positive study. Non-visualization or indeterminate studies were considered negative. We collected pre-test probability of acute appendicitis based on a 10-point visual analog scale (moderate to high was defined as >3), and confidence in CUS interpretation. The primary objective was measured by comparing CUS findings to surgical pathology and one week follow-up. We enrolled 105 patients; 76 had moderate to high pre-test probability. Of these, 24 were children. The rate of appendicitis was 36.8% in those with moderate to high pre-test probability. CUS were recorded by 33 different EPs. The sensitivity, specificity, and positive and negative likelihood ratios of EP-performed CUS in patients with moderate to high pre-test probability were 42.8% (95% confidence interval [CI] [25-62.5%]), 97.9% (95% CI [87.5-99.8%]), 20.7 (95% CI [2.8-149.9]) and 0.58 (95% CI [0.42-0.8]), respectively. The 16 false negative scans were all interpreted as indeterminate. There was one false positive CUS diagnosis; however, the sonographer reported low confidence of 2/10. A heterogeneous group of EP sonographers can safely identify acute appendicitis with high specificity in patients with moderate to high pre-test probability. This data adds support for surgical consultation without further imaging beyond CUS in the appropriate clinical setting.
False-positive cerebrospinal fluid cryptococcus antigen in Libman-Sacks endocarditis.
Isseh, Iyad N; Bourgi, Kassem; Nakhle, Asaad; Ali, Mahmoud; Zervos, Marcus J
2016-12-01
Cryptococcus meningoencephalitis is a serious opportunistic infection associated with high morbidity and mortality in immunocompromised hosts, particularly patients with advanced AIDS disease. The diagnosis is established through cerebrospinal fluid (CSF) cryptococcus antigen detection and cultures. Cryptococcus antigen testing is usually the initial test of choice due its high sensitivity and specificity along with the quick availability of the results. We hereby report a case of a false-positive CSF cryptococcus antigen assay in a patient with systemic lupus erythematosus presenting with acute confusion. While initial CSF evaluation revealed a positive cryptococcus antigen assay, the patient's symptoms were inconsistent with cryptococcus meningoencephalitis. A repeat CSF evaluation, done 3 days later, revealed a negative CSF cryptococcus antigen assay. Given the patient's active lupus disease and the elevated antinuclear antibody titers, we believe that the initial positive result was a false positive caused by interference from autoantibodies.
Basketter, David A; McFadden, John F; Gerberick, Frank; Cockshott, Amanda; Kimber, Ian
2009-02-01
For many regulatory authorities, the local lymph node assay (LLNA) is the preferred assay for the predictive identification of skin-sensitizing chemicals. It is the initial requirement for sensitization testing within the new REACH (Registration, Evaluation, Authorization and Restriction of Chemical substances) regulations in the European Union. The primary reasons for the preferment of the LLNA are the animal welfare benefits it provides compared with traditional guinea-pig methods (refinement and reduction of animal usage) and the general performance characteristics of the assay with regard to overall reliability, accuracy, and interpretation. Moreover, a substantial published literature on the LLNA is available making it appropriate for use as a benchmark against which new approaches, including in vitro alternatives, can be evaluated and validated. There is, therefore, a view that the LLNA represents the 'gold standard' for skin sensitization testing. However, although this is probably correct, it is important to recognize and acknowledge that in common with all other predictive tests (whether they be validated or not), the LLNA has limitations, in addition to strengths, some of which were mentioned above. Arguably, it is the limitations (e.g., the occurrence of false positive and false negative results) of test methods that are most important to understand. With respect to the LLNA, these limitations are similar to those associated with guinea-pig skin sensitization methods. Among these are the occurrence of false positive and false negative results, susceptibility of results to changes in vehicle, and the possibility that interspecies differences may confound interpretation. In this commentary, these issues are reviewed and their impact on the utility of the LLNA for identification, classification, and potency assessment of skin sensitizers are considered. In addition, their relevance for the future development and validation of novel in vitro and in silico alternatives is explored.
False Negatives, Canter's Background Interference Procedure, the Trail Making Test, and Epileptics.
ERIC Educational Resources Information Center
McKinzey, Ronald K.; And Others
1985-01-01
Results of correlation studies of 141 adult epileptics' scores on the Background Interference Procedure (BIP) indicated that the BIP often does not agree with abnormal neurological diagnoses but often does agree with psychiatric diagnoses of Organic Brain Syndrome (OBS). Suggests that future BIP validity studies include a behavioral measure of OBS…
Pulmonary embolism in pregnancy. Consensus and controversies.
Benson, M D
2012-10-01
Venous thrombotic events (VTE) occur 1-2 per 10,000 pregnancies and remain one of the leading causes of maternal mortality in the developed world. The two largest risk factors are a personal history of VTE and heritable thrombophilias. D-dimer tests for VTE in pregnancy have a high false positive rate and at least some false negatives have been reported. Compression ultrasound should be used to evaluate pregnant women for deep venous thrombosis followed by magnetic resonance imaging of the pelvis for a negative test and strong remaining clinical suspicion. For pulmonary embolism, a chest x-ray should be used to triage the patient to either a ventilation/perfusion study after a normal X-ray or a CT pulmonary angiogram after an abnormal one. Treatment generally consists of low molecular weight heparin through a minimum of six weeks post-partum. Thombolysis might have merit in life-threatening, massive pulmonary embolism. VTE prophylaxis in at-risk populations remains a major area of uncertainty. Mechanical prophylaxis for all women undergoing cesarean, in particular, has a paucity of supportive evidence.
Improving Malaria Control in West Africa: Interruption of Transmission as a Paradigm Shift
Doumbia, Seydou O.; Ndiaye, Daouda; Koita, Ousmane A.; Diakité, Mahamadou; Nwakanma, Davis; Coulibaly, Mamadou; Traoré, Sekou F.; Keating, Joseph; Milner, Danny A.; Ndiaye, Jean-Louis; Sene, Papa Diogoye; Ahouidi, Ambroise; Dieye, Tandakha N.; Gaye, Oumar; Okebe, Joseph; Ceesay, Serign J.; Ngwa, Alfred; Oriero, Eniyou C.; Konaté, Lassana; Sy, Ngayo; Jawara, Musa; Faye, Ousmane; Kéita, Moussa; Cissé, Moussa; Sogoba, Nafomon; Poudiougou, Belco; Diawara, Sory; Sangaré, Lansana; Coulibaly, Tinzana; Seck, Ibrahima; Abubakar, Ismaela; Gomis, Jules; Mather, Frances J.; Sissako, Aliou; Diarra, Ayouba; Kandeh, Balla; Whalen, Christopher; Moyer, Brian; Nnedu, Obinna; Thiero, Oumar; Bei, Amy K.; Daniels, Rachel; Miura, Kazutoyo; Long, Carole A.; Fairhurst, Rick M.; Duraisingh, Manoj; Muskavitch, Marc A.T.; D’Alessandro, Umberto; Conway, David J.; Volkman, Sarah K.; Valim, Clarissa; Wirth, Dyann F.; Krogstad, Donald J.
2011-01-01
With the paradigm shift from the reduction of morbidity and mortality to the interruption of transmission, the focus of malaria control broadens from symptomatic infections in children ≤ 5 years of age to include asymptomatic infections in older children and adults. In addition, as control efforts intensify and the number of interventions increases, there will be decreases in prevalence, incidence and transmission with additional decreases in morbidity and mortality. Expected secondary consequences of these changes include upward shifts in the peak ages for infection (parasitemia) and disease, increases in the ages for acquisition of antiparasite humoral and cellular immune responses and increases in false-negative blood smears and rapid diagnostic tests. Strategies to monitor these changes must include: 1] studies of the entire population (that are not restricted to children ≤ 5 or ≤ 10 years of age), 2] study sites in both cities and rural areas (because of increasing urbanization across sub-Saharan Africa) and 3] innovative strategies for surveillance as the prevalence of infection decreases and the frequency of false-negative smears and rapid diagnostic tests increases. PMID:22142790
Buzzi, Marina; Guarino, Anna; Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato
2014-01-01
We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives.
Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato
2014-01-01
We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives. PMID:25397402
Conway, Damian P; Holt, Martin; McNulty, Anna; Couldwell, Deborah L; Smith, Don E; Davies, Stephen C; Cunningham, Philip; Keen, Phillip; Guy, Rebecca
2014-01-01
Determine HIV Combo (DHC) is the first point of care assay designed to increase sensitivity in early infection by detecting both HIV antibody and antigen. We conducted a large multi-centre evaluation of DHC performance in Sydney sexual health clinics. We compared DHC performance (overall, by test component and in early infection) with conventional laboratory HIV serology (fourth generation screening immunoassay, supplementary HIV antibody, p24 antigen and Western blot tests) when testing gay and bisexual men attending four clinic sites. Early infection was defined as either acute or recent HIV infection acquired within the last six months. Of 3,190 evaluation specimens, 39 were confirmed as HIV-positive (12 with early infection) and 3,133 were HIV-negative by reference testing. DHC sensitivity was 87.2% overall and 94.4% and 0% for the antibody and antigen components, respectively. Sensitivity in early infection was 66.7% (all DHC antibody reactive) and the DHC antigen component detected none of nine HIV p24 antigen positive specimens. Median HIV RNA was higher in false negative than true positive cases (238,025 vs. 37,591 copies/ml; p = 0.022). Specificity overall was 99.4% with the antigen component contributing to 33% of false positives. The DHC antibody component detected two thirds of those with early infection, while the DHC antigen component did not enhance performance during point of care HIV testing in a high risk clinic-based population.
Performance of two hearing screening protocols in NICU in Shanghai.
Xu, Zheng-Min; Cheng, Wen-Xia; Yang, Xiao-Lin
2011-10-01
To study the sensitivity and specificity of targeted neonatal hearing screening for the single-session distortion product otoacoustic emissions (DPOAE) technique and the combined DPOAE/automated auditory brain-stem response (AABR) technique. 3000 high-risk newborns were studied at Children's Hospital of Fudan University. They were required to take two different screening procedures separately. The first procedure consisted of DPOAE alone and the second consisted of DPOAE combined with the AABR. Based upon the etiology in high-risk babies, they were divided into four groups. In group I there were 670 very-low-birth-weight (VLBW) newborns (1340 ears), and in group II there were 890 preterm babies (1780 ears). 850 babies (1700 ears) suffered from hyperbilirubinemia in group III, whereas 790 babies (1580 ears) with asphyxia were in group IV. The babies in groups II, III, and IV came from the neonatal intensive-care unit (NICU) of our hospital. The study protocols consisted of the DPOAE alone and DPOAE combined with AABR hearing screening at an age of less than 1 month, and a diagnostic stage at the age of 2 months. With single-session DPOAE screening, the referral rate (8% of the NICU babies), the false-positive rate (4.96%) and the false-negative rate (0.8%) were higher. The different etiologies in NICU babies had significantly different referral rates (F-test, p<0.01). A 4.46% referral rate of hyperbilirubinemi babies was much lower. The combined DPOAE/AABR screening technique revealed a referral rate of 5.03%, a false-positive rate of 2% and a false-negative rate of 0.06%. The false-positive rate was well below the suggested 3% of the American Academy of Pediatric. Comparisons of the referral rate, false-positive rate and false-negative rate of two hearing screening protocols (DPOAE alone and combined DPOAE/AABR) revealed significant differences (t-test, p<0.05, p<0.01, p<0.01). 91 infants (3.03% of the NICU babies) who failed the combined DPOAE/AABR screening were confirmed on hearing impairment. Of 22 babies who passed DPOAE screening but failed the AABR screening had a severe to profound hearing loss based on classic ABR. These patients (24% of the NICU babies with hearing losses) with hyperbilirubinemia and asphyxia problems at newborn stage were diagnosed as auditory neuropathy based on evaluations of DPOAE screening passed, abnormal ABR and absent middle-ear muscle reflexes (MMR). Our study demonstrates the use of a combination of DPOAE and AABR testing ensures high sensitivity and acceptable specificity, and predict the AN profile in NICU babies. Our efforts identified 22 NICU babies with auditory neuropathy who hopefully will benefit from early remediation of their hearing deficit. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Understanding disparities among diagnostic technologies in glaucoma.
De Moraes, Carlos Gustavo V; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C
2012-07-01
To investigate causes of disagreement among 3 glaucoma diagnostic techniques: standard automated achromatic perimetry (SAP), the multifocal visual evoked potential technique (mfVEP), and optical coherence tomography (OCT). In a prospective cross-sectional study, 138 eyes of 69 patients with glaucomatous optic neuropathy were tested using SAP, the mfVEP, and OCT. Eyes with the worse and better mean deviations (MDs) were analyzed separately. If the results of 2 tests were consistent for the presence of an abnormality in the same topographic site, that abnormality was considered a true glaucoma defect. If a third test missed that abnormality (false-negative result), the reasons for disparity were investigated. Eyes with worse MD (mean [SD], -6.8 [8.0] dB) had better agreements among tests than did eyes with better MD (-2.5 [3.5] dB, P<.01). For the 94 of 138 hemifields with abnormalities of the more advanced eyes, the 3 tests were consistent in showing the same hemifield abnormality in 50 hemifields (53%), and at least 2 tests were abnormal in 65 of the 94 hemifields (69%). The potential explanations for the false-negative results fell into 2 general categories: inherent limitations of each technique to detect distinct features of glaucoma and individual variability and the distribution of normative values used to define statistically significant abnormalities. All the cases of disparity could be explained by known limitations of each technique and interindividual variability, suggesting that the agreement among diagnostic tests may be better than summary statistics suggest and that disagreements between tests do not indicate discordance in the structure-function relationship.
Evans, D. A.; Brownlow, N. D.; Hersh, W. R.; Campbell, E. M.
1996-01-01
We discuss the development and evaluation of an automated procedure for extracting drug-dosage information from clinical narratives. The process was developed rapidly using existing technology and resources, including categories of terms from UMLS96. Evaluations over a large training and smaller test set of medical records demonstrate an approximately 80% rate of exact and partial matches' on target phrases, with few false positives and a modest rate of false negatives. The results suggest a strategy for automating general concept identification in electronic medical records. PMID:8947694
Wu, Zhijin; Liu, Dongmei; Sui, Yunxia
2008-02-01
The process of identifying active targets (hits) in high-throughput screening (HTS) usually involves 2 steps: first, removing or adjusting for systematic variation in the measurement process so that extreme values represent strong biological activity instead of systematic biases such as plate effect or edge effect and, second, choosing a meaningful cutoff on the calculated statistic to declare positive compounds. Both false-positive and false-negative errors are inevitable in this process. Common control or estimation of error rates is often based on an assumption of normal distribution of the noise. The error rates in hit detection, especially false-negative rates, are hard to verify because in most assays, only compounds selected in primary screening are followed up in confirmation experiments. In this article, the authors take advantage of a quantitative HTS experiment in which all compounds are tested 42 times over a wide range of 14 concentrations so true positives can be found through a dose-response curve. Using the activity status defined by dose curve, the authors analyzed the effect of various data-processing procedures on the sensitivity and specificity of hit detection, the control of error rate, and hit confirmation. A new summary score is proposed and demonstrated to perform well in hit detection and useful in confirmation rate estimation. In general, adjusting for positional effects is beneficial, but a robust test can prevent overadjustment. Error rates estimated based on normal assumption do not agree with actual error rates, for the tails of noise distribution deviate from normal distribution. However, false discovery rate based on empirically estimated null distribution is very close to observed false discovery proportion.
False Negative Urine Pregnancy Testing with Complete Molar Pregnancy: An Example of the Hook Effect.
Anderson, Zachary; Larson, Eric; Khan, Muhammad; Bell, Maria
2016-02-01
Gestational trophoblastic disease (GTD) encompasses a group of tumors derived from trophoblasts, which normally form the placenta during pregnancy. Human chorionic gonadotropin (hCG) is a glycoprotein composed of an alpha subunit identical to that of thyroid stimulating hormone (TSH), follicle-stimulating hormone (FSH), and luteinizing hormone (LH). Detection of beta-hCG is achievable in both urine and serum samples, proving useful for the detection of normal pregnancy and GTD. However, in the presence of very high levels of beta-hCG, a false negative result may be obtained due to a phenomenon called the "hook effect" or "prozone phenomenon." In certain circumstances, trophoblastic tumors can produce very high levels of beta-hCG, causing misleading results on urine pregnancy testing. A 49-year-old Caucasian female with past medical history pertinent for deep vein thrombosis, ovarian cysts, and osteopenia presented to her internist with report of irregular uterine bleeding for the preceding three months, accompanied by complaints of abdominal bloating, night sweats, and constipation. The patient stated she had completed two negative qualitative urine pregnancy tests and had been seen by both gynecology and gastroenterology, with recommendations to start supplemental estrogen for her symptoms and begin additional fiber intake for irritable bowel syndrome, respectively. Despite negative urine beta-hCG, a quantitative serum beta-hCG was obtained and revealed a level greater than 200,000 international units (IU). The patient was referred to gynecologic oncology and an open abdominal hysterectomy with preservation of her ovaries was performed. Histopathologic examination showed a complete hydatiform mole with no evidence of invasion. The case highlights the importance of clinical judgment in modern medicine, where biochemical methods and imaging modalities have become main stays in diagnosis. As mentioned, there are ways to reduce the incidence of the hook effect, but with added time and cost. Clinicians need to consider the possibility of the hook effect for instances where the clinical picture points to a disease entity despite negative test results. Delaying diagnoses, as illustrated with GTD, has the potential to cause significant morbidity and mortality.
Analysis of false results in a series of 835 fine needle aspirates of breast lesions.
Willis, S L; Ramzy, I
1995-01-01
To analyze cases of false diagnoses from a large series to help increase the accuracy of fine needle aspiration of palpable breast lesions. The results of FNA of 835 palpable breast lesions were analyzed to determine the reasons for false positive, false negative and false suspicious diagnoses. Of the 835 aspirates, 174 were reported as positive, 549 as negative and 66 as suspicious or atypical but not diagnostic of malignancy. Forty-six cases were considered unsatisfactory. Tissue was available for comparison in 286 cases. The cytologic diagnoses in these cases were reported as follows: positive, 125 (43.7%); suspicious, 33 (11.5%); atypical, 18 (6.2%); negative, 92 (32%); and unsatisfactory, 18 (6.2%). There was one false positive diagnosis, yielding a false positive rate of 0.8%. This lesion was a case of fibrocystic change with hyperplasia, focal fat necrosis and reparative atypia. There were 14 false negative cases, resulting in a false negative rate of 13.2%. Nearly all these cases were sampling errors and included infiltrating ductal carcinomas (9), ductal carcinomas in situ (2), infiltrating lobular carcinomas (2) and tubular carcinoma (1). Most of the suspicious and atypical lesions proved to be carcinomas (35/50). The remainder were fibroadenomas (6), fibrocystic change (4), gynecomastia (2), adenosis (2) and granulomatous mastitis (1). A positive diagnosis of malignancy by FNA is reliable in establishing the diagnosis and planning the treatment of breast cancer. The false-positive rate is very low, with only a single case reported in 835 aspirates. Most false negatives are due to sampling and not to interpretive difficulties. The category "suspicious but not diagnostic of malignancy" serves a useful purpose in management of patients with breast lumps.
Kang, Stella K; Jiang, Miao; Duszak, Richard; Heller, Samantha L; Hughes, Danny R; Moy, Linda
2018-06-05
Purpose To retrospectively assess whether there is an association between screening mammography and the use of a variety of preventive services in women who are enrolled in Medicare. Materials and Methods U.S. Medicare claims from 2010 to 2014 Research Identifiable Files were reviewed to retrospectively identify a group of women who underwent screening mammography and a control group without screening mammography in 2012. The screened group was divided into positive versus negative results at screening, and the positive subgroup was divided into false-positive and true-positive findings. Multivariate logistic regression models and inverse probability of treatment weighting were used to examine the relationship between screening status and the probabilities of undergoing Papanicolaou test, bone mass measurement, or influenza vaccination in the following 2 years. Results The cohort consisted of 555 705 patients, of whom 185 625 (33.4%) underwent mammography. After adjusting for patient demographics, comorbidities, geographic covariates, and baseline preventive care, women who underwent index screening mammography (with either positive or negative results) were more likely than unscreened women to later undergo Papanicolaou test (odds ratio [OR], 1.49; 95% confidence interval: 1.40, 1.58), bone mass measurement (OR, 1.70; 95% confidence interval: 1.63, 1.78), and influenza vaccine (OR, 1.45; 95% confidence interval: 1.37, 1.53). In women who had not undergone these preventive measures in the 2 years before screening mammography, use of these three services after false-positive findings at screening was no different than after true-negative findings at screening. Conclusion In beneficiaries of U.S. Medicare, use of screening mammography was associated with higher likelihood of adherence to other preventive guidelines, without a negative association between false-positive results and cervical cancer screening. © RSNA, 2018 Online supplemental material is available for this article.
[Children with hyperthyroidism due to elevated hCG levels].
Jöbsis, Jasper J; van Trotsenburg, A S Paul; Merks, Johannes H M; Kamp, Gerdine A
2014-01-01
We describe two children with hyperthyroidism secondary to elevated hCG levels: one patient with gestational trophoblastic disease and one patient with choriocarcinoma. hCG resembles other glycoproteins that can lead to hyperthyroidism through TSH receptor activation. Also, through its LH-mimicking effect, hCG can induce high oestradiol levels, resulting in stormy pubertal development. False negative hCG tests due to the high-dose hook effect may complicate the diagnostic process. In patients with antibody-negative thyrotoxicosis, the diagnosis of hCG-induced hyperthyroidism must be considered.
Purrucker, Jan C; Haas, Kirsten; Rizos, Timolaos; Khan, Shujah; Poli, Sven; Kraft, Peter; Kleinschnitz, Christoph; Dziewas, Rainer; Binder, Andreas; Palm, Frederick; Jander, Sebastian; Soda, Hassan; Heuschmann, Peter U; Veltkamp, Roland
2017-01-01
In patients who present with acute ischemic stroke while on treatment with non-vitamin K antagonist oral anticoagulants (NOACs), coagulation testing is necessary to confirm the eligibility for thrombolytic therapy. We evaluated the current use of coagulation testing in routine clinical practice in patients who were on NOAC treatment at the time of acute ischemic stroke. Prospective multicenter observational RASUNOA registry (Registry of Acute Stroke Under New Oral Anticoagulants; February 2012-2015). Results of locally performed nonspecific (international normalized ratio, activated partial thromboplastin time, and thrombin time) and specific (antifactor Xa tests, hemoclot assay) coagulation tests were documented. The implications of test results for thrombolysis decision-making were explored. In the 290 patients enrolled, nonspecific coagulation tests were performed in ≥95% and specific coagulation tests in 26.9% of patients. Normal values of activated partial thromboplastin time and international normalized ratio did not reliably rule out peak drug levels at the time of the diagnostic tests (false-negative rates 11%-44% [95% confidence interval 1%-69%]). Twelve percent of patients apparently failed to take the prescribed NOAC prior to the acute event. Only 5.7% (9/159) of patients in the 4.5-hour time window received thrombolysis, and NOAC treatment was documented as main reason for not administering thrombolysis in 52.7% (79/150) of patients. NOAC treatment currently poses a significant barrier to thrombolysis in ischemic stroke. Because nonspecific coagulation test results within normal range have a high false-negative rate for detection of relevant drug concentrations, rapid drug-specific tests for thrombolysis decision-making should be established. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01850797. © 2016 American Heart Association, Inc.
Prince, Harry E; Altrich, Michelle L; Nowicki, Marek J
2016-10-01
The identification of nearly 3,500 cases of chikungunya virus (CHIKV) infection in U.S. residents returning in 2014 and 2015 from areas in which it is endemic has raised concerns within the transplant community that, should recently infected individuals become organ and/or tissue donors, CHIKV would be transmitted to transplant recipients. Thus, tests designed to detect recent CHIKV infection among U.S. organ and tissue donors may become necessary in the future. Accordingly, we evaluated 2 enzyme-linked immunosorbent assays (ELISAs) for CHIKV IgM readily available in the United States using 1,000 deidentified serum or plasma specimens collected from donors between November 2014 and March 2015. The Euroimmun indirect ELISA identified 38 reactive specimens; however, all 38 were negative for CHIKV IgG and IgM in immunofluorescence assays (IFAs) conducted at a reference laboratory and, thus, were falsely reactive in the Euroimmun CHIKV IgM assay. The InBios IgM-capture ELISA identified 26 reactive samples, and one was still reactive (index ≥ 1.00) when retested using the InBios kit with a background subtraction modification to identify false reactivity. This reactive specimen was CHIKV IgM negative but IgG positive by IFAs at two reference laboratories; plaque reduction neutralization testing (PRNT) demonstrated CHIKV-specific reactivity. The IgG and PRNT findings strongly suggest that the InBios CHIKV IgM-reactive result represents true reactivity, even though the IgM IFA result was negative. If testing organ/tissue donors for CHIKV IgM becomes necessary, the limitations of the currently available CHIKV IgM ELISAs and options for their optimization must be understood to avoid organ/tissue wastage due to falsely reactive results. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Blaser, Simon; Diem, Hanspeter; von Felten, Andreas; Gueuning, Morgan; Andreou, Michael; Boonham, Neil; Tomlinson, Jennifer; Müller, Pie; Utzinger, Jürg; Frey, Jürg E; Bühlmann, Andreas
2018-06-01
Rapid genetic on-site identification methods at points of entry, such as seaports and airports, have the potential to become important tools to prevent the introduction and spread of economically harmful pest species that are unintentionally transported by the global trade of plant commodities. This paper reports the development and evaluation of a loop-mediated isothermal amplification (LAMP)-based identification system to prevent introduction of the three most frequently encountered regulated quarantine insect species groups at Swiss borders, Bemisia tabaci, Thrips palmi and several regulated fruit flies of the genera Bactrocera and Zeugodacus. The LAMP primers were designed to target a fragment of the mitochondrial cytochrome c oxidase subunit I gene and were generated based on publicly available DNA sequences. Laboratory evaluations analysing 282 insect specimens suspected to be quarantine organisms revealed an overall test efficiency of 99%. Additional on-site evaluation at a point of entry using 37 specimens performed by plant health inspectors with minimal laboratory training resulted in an overall test efficiency of 95%. During both evaluation rounds, there were no false-positives and the observed false-negatives were attributable to human-induced manipulation errors. To overcome the possibility of accidental introduction of pests as a result of rare false-negative results, samples yielding negative results in the LAMP method were also subjected to DNA barcoding. Our LAMP assays reliably differentiated between the tested regulated and non-regulated insect species within <1 h. Hence, LAMP assays represent suitable tools for rapid on-site identification of harmful pests, which might facilitate an accelerated import control process for plant commodities. © 2018 The Authors. Pest Management Science published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry. © 2018 The Authors. Pest Management Science published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry.
Discrete emotion-congruent false memories in the DRM paradigm.
Bland, Cassandra E; Howe, Mark L; Knott, Lauren
2016-08-01
Research has shown that false-memory production is enhanced for material that is emotionally congruent with the mood of the participant at the time of encoding. So far this research has only been conducted to examine the influence of generic negative affective mood states and generic negative stimuli on false-memory production. In addition, much of the research is limited as it focuses on valence and arousal dimensions, and fails to take into account the more comprehensive nature of emotions. The current study demonstrates that this effect goes beyond general negative or positive moods and acts at a more discrete emotional level. Participants underwent a standard emotion-induction procedure before listening to negative emotional or neutral associative word lists. The emotions induced, negative word lists, and associated nonpresented critical lures, were related to either fear or anger, 2 negative valence emotions that are also both high in arousal. Results showed that when valence and arousal are controlled for, false memories are more likely to be produced for discrete emotionally congruent compared with incongruent materials. These results support spreading activation theories of false remembering and add to our understanding of the adaptive nature of false-memory production. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Stirling, Paul; Faroug, Radwane; Amanat, Suheil; Ahmed, Abdulkhaled; Armstrong, Malcolm; Sharma, Pankaj; Qamruddin, Ahmed
2014-01-01
We quantify the false-negative diagnostic rate of septic arthritis using Gram-stain microscopy of synovial fluid and compare this to values reported in the peer-reviewed literature. We propose a method of improving the diagnostic value of Gram-stain microscopy using Lithium Heparin containers that prevent synovial fluid coagulation. Retrospective study of the Manchester Royal Infirmary microbiology database of patients undergoing synovial fluid Gram-stain and culture between December 2003 and March 2012 was undertaken. The initial cohort of 1896 synovial fluid analyses for suspected septic arthritis was reduced to 143 after exclusion criteria were applied. Analysis of our Gram-stain microscopy yielded 111 false-negative results from a cohort size of 143 positive synovial fluid cultures, giving a false-negative rate of 78%. We report a false-negative rate of Gram-stain microscopy for septic arthritis of 78%. Clinicians should therefore avoid the investigation until a statistically significant data set confirms its efficacy. The investigation's value could be improved by using Lithium Heparin containers to collect homogenous synovial fluid samples. Ongoing research aims to establish how much this could reduce the false-negative rate.
van Rooijen, Martijn S; Roest, Wim; Hansen, Gino; Kwa, David; de Vries, Henry J C
2016-06-01
Herpes simplex virus (HSV) type-discriminating antibody tests (glycoprotein G (gG) directed) are used to identify naïve persons and differentiate acute infections from recurrences. We studied test characteristics of three commercially available antibody tests in patients with recurrent (established by viral PCR tests) herpes simplex virus type 1 (HSV-1) or herpes simplex virus type 2 (HSV-2) genital herpes episodes. Serum samples (at minimum 3 months after t=0) were examined for the presence of gG-1-specific or gG-2-specific antibodies using the HerpeSelect 1 and 2 Immunoblot IgG, the HerpeSelect 1 and 2 enzyme linked immunoassays IgG and the LIAISON HSV-1 and HSV-2 IgG indirect chemiluminescence immunoassays. The immunoblot was HSV-1 positive in 70.6% (95% CI 44.0% to 89.7%), the LIAISON in 88.2% (95% CI 63.5% to 98.5%) and the ELISA in 82.4% (95% CI 56.6% to 96.2%) of the 17 patients with a recurrent HSV-1 episode. From 33 patients with a recurrent HSV-2 episode, the immunoblot was HSV-2 positive in 84.8% (95% CI 68.1% to 94.9%), the LIAISON in 69.7% (95% CI 51.3% to 84.4%) and the ELISA in 84.8% (95% CI 68.1% to 94.9%). Among 15/17 (88.2%; 95% CI 63.5% to 98.5%) patients with HSV-1 and 30/33 (90.1%; 95% CI 75.7% to 98.1%) patients with HSV-2, HSV-1 or HSV-2 antibodies, respectively, were detected in at least one of the three antibody tests. Commercial type-specific gG HSV-1 or HSV-2 antibody assays were false negative in 12-30% of patients with recurrent HSV-1 or HSV-2 DNA positive genital lesions. The clinical and epidemiological use of type-specific HSV serology can be hampered by false-negative results, especially if based on a single test. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Nortunen, S; Flinkkilä, T; Lantto, I; Kortekangas, T; Niinimäki, J; Ohtonen, P; Pakarinen, H
2015-08-01
We prospectively assessed the diagnostic accuracy of the gravity stress test and clinical findings to evaluate the stability of the ankle mortise in patients with supination-external rotation-type fractures of the lateral malleolus without widening of the medial clear space. The cohort included 79 patients with a mean age of 44 years (16 to 82). Two surgeons assessed medial tenderness, swelling and ecchymosis and performed the external rotation (ER) stress test (a reference standard). A diagnostic radiographer performed the gravity stress test. For the gravity stress test, the positive likelihood ratio (LR) was 5.80 with a 95% confidence interval (CI) of 2.75 to 12.27, and the negative LR was 0.15 (95% CI 0.07 to 0.35), suggesting a moderate change from the pre-test probability. Medial tenderness, both alone and in combination with swelling and/or ecchymosis, indicated a small change (positive LR, 2.74 to 3.25; negative LR, 0.38 to 0.47), whereas swelling and ecchymosis indicated only minimal changes (positive LR, 1.41 to 1.65; negative LR, 0.38 to 0.47). In conclusion, when gravity stress test results are in agreement with clinical findings, the result is likely to predict stability of the ankle mortise with an accuracy equivalent to ER stress test results. When clinical examination suggests a medial-side injury, however, the gravity stress test may give a false negative result. ©2015 The British Editorial Society of Bone & Joint Surgery.
Herbert, C; Kissler, J
2014-09-26
In sentences such as dogs cannot fly/bark, evaluation of the truth-value of the sentence is assumed to appear after the negation has been integrated into the sentence structure. Moreover negation processing and truth-value processing are considered effortful processes, whereas processing of the semantic relatedness of the words within sentences is thought to occur automatically. In the present study, modulation of event-related brain potentials (N400 and late positive potential, LPP) was investigated during an implicit task (silent listening) and active truth-value evaluation to test these theoretical assumptions and determine if truth-value evaluation will be modulated by the way participants processed the negated information implicitly prior to truth-value verification. Participants first listened to negated sentences and then evaluated these sentences for their truth-value in an active evaluation task. During passive listening, the LPP was generally more pronounced for targets in false negative (FN) than true negative (TN) sentences, indicating enhanced attention allocation to semantically-related but false targets. N400 modulation by truth-value (FN>TN) was observed in 11 out of 24 participants. However, during active evaluation, processing of semantically-unrelated but true targets (TN) elicited larger N400 and LPP amplitudes as well as a pronounced frontal negativity. This pattern was particularly prominent in those 11 individuals, whose N400 modulation during silent listening indicated that they were more sensitive to violations of the truth-value than to semantic priming effects. The results provide evidence for implicit truth-value processing during silent listening of negated sentences and for task dependence related to inter-individual differences in implicit negation processing. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.
Thermal Threshold: Research Study on Small Fiber Dysfunction in Distal Diabetic Polyneuropathy
Jimenez-Cohl, Pedro; Grekin, Carlos; Leyton, Cristian; Vargas, Claudio; Villaseca, Roberto
2012-01-01
Objective The most commonly used technique for diagnosis of diabetic neuropathy (DN) is nervous conduction (NC). Our hypothesis is that the use of the thermal threshold (TT) technique to evaluate small fiber damage, which precedes large fiber damage, could enable earlier diagnosis and diminish false negatives. Research Design and Methods The study involved 70 asymptomatic patients with type 2 diabetes mellitus (T2DM) all being treated with oral hypoglycemic medication, and having negative metabolic control levels with glycosylated hemoglobin A1c greater than 7% and less than 8%. Diabetic neuropathy was their only evident complication. All other complications or other causes of neuropathy were discarded. Their time of evolution was 1 to 48 months since date of diagnosis of diabetes. Both thermal threshold and sensory and motor nervous conduction were determined in upper and lower limbs. Results Nervous conduction was found normal in 81% and altered in 19% of patients (large fiber neuropathy). Thermal threshold was normal in 57% and altered in 43% of patients (small fiber neuropathy). In those with normal TTs, no case with an altered NC was found (p < 0.001). Patients with altered TTs could have normal (57%) or altered NC (43%). Thus, NC showed a high frequency of false negatives for DN (57% of 30 cases). The frequency of small fiber neuropathy found with the TT test was higher than that of large fiber neuropathy found with the NC test (p < 0.001) and was found at an earlier age. Conclusions The TT test demonstrated a higher frequency of neuropathy than the NC test in clinically asymptomatic T2DM patients. We suggest that small fiber should be studied before large fiber function to diagnosis distal and symmetrical DN. PMID:22401337
Yoon, Jung Hyun; Jung, Hae Kyoung; Lee, Jong Tae; Ko, Kyung Hee
2013-09-01
To investigate the factors that have an effect on false-positive or false-negative shear-wave elastography (SWE) results in solid breast masses. From June to December 2012, 222 breast lesions of 199 consecutive women (mean age: 45.3 ± 10.1 years; range, 21 to 88 years) who had been scheduled for biopsy or surgical excision were included. Greyscale ultrasound and SWE were performed in all women before biopsy. Final ultrasound assessments and SWE parameters (pattern classification and maximum elasticity) were recorded and compared with histopathology results. Patient and lesion factors in the 'true' and 'false' groups were compared. Of the 222 masses, 175 (78.8 %) were benign, and 47 (21.2 %) were malignant. False-positive rates of benign masses were significantly higher than false-negative rates of malignancy in SWE patterns, 36.6 % to 6.4 % (P < 0.001). Among both benign and malignant masses, factors showing significance among false SWE features were lesion size, breast thickness and lesion depth (all P < 0.05). All 47 malignant breast masses had SWE images of good quality. False SWE features were more significantly seen in benign masses. Lesion size, breast thickness and lesion depth have significance in producing false results, and this needs consideration in SWE image acquisition. • Shear-wave elastography (SWE) is widely used during breast imaging • At SWE, false-positive rates were significantly higher than false-negative rates • Larger size, breast thickness, depth and fair quality influences false-positive SWE features • Smaller size, larger breast thickness and depth influences false-negative SWE features.
Kermani, Bahram G
2016-07-01
Crystal Genetics, Inc. is an early-stage genetic test company, focused on achieving the highest possible clinical-grade accuracy and comprehensiveness for detecting germline (e.g., in hereditary cancer) and somatic (e.g., in early cancer detection) mutations. Crystal's mission is to significantly improve the health status of the population, by providing high accuracy, comprehensive, flexible and affordable genetic tests, primarily in cancer. Crystal's philosophy is that when it comes to detecting mutations that are strongly correlated with life-threatening diseases, the detection accuracy of every single mutation counts: a single false-positive error could cause severe anxiety for the patient. And, more importantly, a single false-negative error could potentially cost the patient's life. Crystal's objective is to eliminate both of these error types.
[Comparison of eight screening tests for ant-HCV antibody].
Deguchi, Matsuo; Kagita, Masanori; Yamashita, Naoko; Nakano, Takasi; Tahara, Kazuko; Asari, Seishi; Iwatani, Yoshinori
2002-09-01
We compared eight HCV screening tests for detection of anti-HCV antibody; Ortho Quick Chaser HCV Ab (QC), Ortho HCV Ab ELISA III (ELISA), Ortho HVC Ab PA test III (PA), Lumipulse II Ortho HCV (LUMI), IMx HCV.DAINAPACKII (IMx), ARCHITECT HCV (ARCH), Immucheck.F-HCV C50 Ab (Immu), RANREAM HCV Ab Ex II (RAN). Sera from six hundred patients were examined by these eight screening tests. The positive rates of the eight screening tests were from 9.0% to 13.2%. Forty-five sera showed discrepant results between the eight screening tests, and about half of them showed weak positive reaction and/or false positive. Twenty-five of the forty-five sera were negative for ant-HCV antibody in the CHIRON RIBA III confirmatory test, and forty-four of them were negative for HCV-RNA in the PCR method. The agreement rates between the two reagents were from 95.5% to 99.2%, but were not always high between the two reagents that used similar antigen. The specificities and sensitivities evaluated by using the RIBA III confirmatory test were excellent in ELISA, LUMI, IMx, ARCH and Immu. Three BBI seroconversion panels were used to compare the positive readings in the initial stage of HCV infection by eight screening tests. ELISA and ARCH showed the earliest positive readings, and then IMx, LUMI = RAN, PA, QC and Immu in this order. These findings indicate that ELISA and ARCH were the most excellent in the sensitivity, specificity and early diagnosis of HCV infection. However, we must pay attention to the weak positive reaction in the screening tests, because there is a possibility of "false positive".
Stress and anxiety effects on positive skin test responses in young adults with allergic rhinitis.
Heffner, Kathi L; Kiecolt-Glaser, Janice K; Glaser, Ronald; Malarkey, William B; Marshall, Gailen D
2014-07-01
Anxiety and psychological stress affect allergy-related immune function. How these relations influence the evaluations of patients with allergic rhinitis is unknown. To examine whether anxiety and stress exposure affect skin prick test (SPT) responses to common allergens for which patients with atopy showed no prior positive SPT response. Patients with allergic rhinitis, evidenced by clinical history and SPT results, were admitted twice to a hospital research unit for 4 hours. In a crossover design, SPT wheals were assessed before and after the Trier Social Stress Test and then the following morning; for comparison, SPT wheals were assessed before and after a laboratory session without a stressor. Analyses focused on wheal responses for common allergens that tested negative (wheal size <3 mm larger than saline) from SPTs performed at multiple baseline assessments. After the Trier Social Stress Test, more anxious patients with atopy had a higher incidence of positive SPT reactions to antigens that previously tested negative. Anxiety was unrelated to positive SPT incidence under nonstressful conditions. Based on clinical symptom reports, newly positive SPT reactions after the stressor were apparently corrections of previously false-negative SPT reactions. The SPT wheal responses for allergens previously testing negative were enhanced after a stressor. Histamine (positive control) or saline (negative control) SPT responses were not affected. A laboratory stressor affected allergen SPT responses in more anxious patients with allergic rhinitis. In addition to clinical history, assessment of anxiety and current stress at the time of the SPT may provide valuable information about a patient's allergic status and aid in clinical decision making. Copyright © 2014 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Verstraelen, Sandra; Maglennon, Gareth; Hollanders, Karen; Boonen, Francis; Adriaens, Els; Alépée, Nathalie; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Kandarova, Helena; Willoughby, Jamin A; Guest, Robert; Schofield, Jane; Van Rompay, An R
2018-06-01
Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.
Verstraelen, Sandra; Maglennon, Gareth; Hollanders, Karen; Boonen, Francis; Adriaens, Els; Alépée, Nathalie; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Kandarova, Helena; Willoughby, Jamin A; Guest, Robert; Schofield, Jane; Van Rompay, An R
2017-10-01
Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.
The Accidental Transgressor: Morally Relevant Theory of Mind
Killen, Melanie; Mulvey, Kelly Lynn; Richardson, Cameron; Jampol, Noah
2014-01-01
To test young children’s false belief theory of mind in a morally relevant context, two experiments were conducted. In Experiment 1, children (N = 162) at 3.5, 5.5, and 7.5 years of age were administered 3 tasks: prototypic moral transgression task, false belief theory of mind task (ToM), and an “accidental transgressor” task, which measured a morally relevant false belief theory of mind (MoToM). Children who did not pass false belief ToM were more likely to attribute negative intentions to an accidental transgressor than children who passed false belief ToM, and to use moral reasons when blaming the accidental transgressor. In Experiment 2, children (N = 46) who did not pass false belief ToM viewed it as more acceptable to punish the accidental transgressor than did participants who passed false belief ToM. Findings are discussed in light of research on the emergence of moral judgment and theory of mind. PMID:21377148
Cumulative False-Positive QuantiFERON-TB Interferon-γ Release Assay Results.
Gamsky, Thomas E; Lum, Thomas; Hung-Fan, Melody; Green, Jon A
2016-05-01
Despite reports of unreliability, the QuantiFERON-TB interferon-γ release assay is increasingly used for the annual screening of individuals at risk for latent tuberculosis. Continued use of the QuantiFERON-TB assay suggests the need for more definitive evidence of its reproducibility and accuracy. To examine reproducibility and the accumulation of false-positive test results when the QuantiFERON-TB is repeated annually and to examine the validity of confirming positive test results with the performance of a second QuantiFERON-TB. We performed a retrospective, longitudinal evaluation of results from serial screening of a cohort of emergency responders from 2001 to 2013. Results of tuberculin tests and QuantiFERON-TB tests performed annually as part of a mandated first responder examination were retroactively reviewed. In this population, positive results occurred in new individuals each year. QuantiFERON-TB results were positive in 80 of 557 tuberculin test-negative individuals examined annually for a maximum of 7 years. Only 10 individuals with initially positive results remained positive when the test was repeated the next year, and 9 of these 10 were QuantiFERON-TB-negative within 3 years. The number of individuals with a positive result increased annually, and, after 7 years, 32 (27.4%) of 117 people had a positive result. When viewed in the context of the extensive literature documenting unreliable QuantiFERON-TB test performance, our findings of frequent, cumulative, sporadic, and irreproducible positive results support discontinuing the use of the QuantiFERON-TB assay for the diagnosis of latent tuberculosis in low-risk populations.
The problem of false positives and false negatives in violent video game experiments.
Ferguson, Christopher J
The problem of false positives and negatives has received considerable attention in behavioral research in recent years. The current paper uses video game violence research as an example of how such issues may develop in a field. Despite decades of research, evidence on whether violent video games (VVGs) contribute to aggression in players has remained mixed. Concerns have been raised in recent years that experiments regarding VVGs may suffer from both "false positives" and "false negatives." The current paper examines this issue in three sets of video game experiments, two sets of video game experiments on aggression and prosocial behaviors identified in meta-analysis, and a third group of recent null studies. Results indicated that studies of VVGs and aggression appear to be particularly prone to false positive results. Studies of VVGs and prosocial behavior, by contrast are heterogeneous and did not demonstrate any indication of false positive results. However, their heterogeneous nature made it difficult to base solid conclusions on them. By contrast, evidence for false negatives in null studies was limited, and little evidence emerged that null studies lacked power in comparison those highlighted in past meta-analyses as evidence for effects. These results are considered in light of issues related to false positives and negatives in behavioral science more broadly. Copyright © 2017 Elsevier Ltd. All rights reserved.
Renshaw, A A; Lezon, K M; Wilbur, D C
2001-04-25
Routine quality control rescreening often is used to calculate the false-negative rate (FNR) of gynecologic cytology. Theoretic analysis suggests that this is not appropriate, due to the high FNR of rescreening and the inability to actually measure it. The authors sought to determine the FNR of manual rescreening in a large, prospective, two-arm clinical trial using an analytic instrument in the evaluation. The results of the Autopap System Clinical Trial, encompassing 25,124 analyzed slides, were reviewed. The false-negative and false-positive rates at various thresholds were determined for routine primary screening, routine rescreening, Autopap primary screening, and Autopap rescreening by using a simple, standard methodology. The FNR of routine manual rescreening at the level of atypical squamous cells of undetermined significance (ASCUS) was 73%, more than 3 times the FNR of primary screening; 11 cases were detected. The FNR of Autopap rescreening was 34%; 80 cases were detected. Routine manual rescreening decreased the laboratory FNR by less than 1%; Autopap rescreening reduced the overall laboratory FNR by 5.7%. At the same time, the false-positive rate for Autopap screening was significantly less than that of routine manual screening at the ASCUS level (4.7% vs. 5.6%; P < 0.0001). Rescreening with the Autopap system remained more sensitive than manual rescreening at the low grade squamous intraepithelial lesions threshold (FNR of 58.8% vs. 100%, respectively), although the number of cases rescreened was low. Routine manual rescreening cannot be used to calculate the FNR of primary screening. Routine rescreening is an extremely ineffective method to detect error and thereby decrease a laboratory's FNR. The Autopap system is a much more effective way of detecting errors within a laboratory and reduces the laboratory's FNR by greater than 25%.
Prevention. How much harm? How much benefit? 3. Physical, psychological and social harm.
Marshall, K G
1996-01-01
Harm caused by preventive programs may be physical, psychological, social or, if informed consent has not been obtained, ethical. Adverse effects of preventive screening programs may occur at any of the three levels of the "screening cascade", the screening procedure itself, the investigation of abnormal results of screening tests or the treatment of detected abnormalities or diseases. The greatest harm occurs at the second and third levels. Examples of procedures that may cause physical harm are venipuncture, mammography, colonoscopy, breast biopsy, transrectal ultrasonography, prostate biopsy, weight-reducing and cholesterol-lowering diets and radical prostatectomy. The psychological and social harm of preventive programs involves anticipated discomfort or perception of adverse effects of preventive interventions; unpleasant interactions with health care workers, time required for preventive programs, excessive overall awareness of health, anxiety over the results of a screening test implications of a positive screening test, consequences of being labelled as "sick" or "at risk," psychopathologic effects induced directly by preventive programs and, in the case of a false-negative test result, false assurance of disease-free status. Since the positive predictive value of screening tests in the general population is always low, most abnormal test results are "false-positive," these engender a great deal of psychological discuss among patients. PMID:8800074
Abercrombie, M L; Jewell, J S
1986-01-01
Results of EMIT, Abuscreen RIA, and GC/MS tests for THC metabolites in a high volume random urinalysis program are compared. Samples were field tested by non-laboratory personnel with an EMIT system using a 100 ng/mL cutoff. Samples were then sent to the Army Forensic Toxicology Drug Testing Laboratory (WRAMC) at Fort Meade, Maryland, where they were tested by RIA (Abuscreen) using a statistical 100 ng/mL cutoff. Confirmations of all RIA positives were accomplished using a GC/MS procedure. EMIT and RIA results agreed for 91% of samples. Data indicated a 4% false positive rate and a 10% false negative rate for EMIT field testing. In a related study, results for samples which tested positive by RIA for THC metabolites using a statistical 100 ng/mL cutoff were compared with results by GC/MS utilizing a 20 ng/mL cutoff for the THCA metabolite. Presence of THCA metabolite was detected in 99.7% of RIA positive samples. No relationship between quantitations determined by the two tests was found.
Performance of Momguard, a new non-invasive prenatal testing protocol developed in Korea.
Lee, Mi-Young; Cho, Dae-Yeon; Won, Hye-Sung; Hwang, Ah Reum; Jeong, Bada; Kim, Jihun; Oh, Mijin
2015-09-01
To evaluate the performance of Momguard, non-invasive prenatal test (NIPT) for detecting trisomy (T) 21, T18, T13, and sex-chromosome abnormalities recently developed in Korea. This preliminary study formed part of a large prospective cohort study conducted at Asan Medical Center, Seoul, Korea. Only pregnant women who underwent both NIPT and confirmatory karyotyping were included in this study. NIPT results were compared with those of karyotype analyses. Among 93 eligible cases, NIPT results could not be obtained in one case due to a low fetal cell-free DNA fraction. Based on NIPT, eight cases of fetal aneuploidies, including T21 (n=5), T18 (n=2), and T13 (n=1), were identified. For T21 and T18, the sensitivity and specificity of NIPT were both 100%, with a false-positive and false-negative rate of 0% and a positive-predictive value of 100%. One patient classified as having intermediate risk for T13 by NIPT was confirmed to have T13 by karyotyping, and there were no false-negative cases. No cases of sex-chromosome anomalies were detected by NIPT or karyotyping during the study period. Momguard is a reliable screening tool for detecting T21 and T18. For T13 and sex-chromosome anomalies, further prospective studies are necessary to confirm its utility.
Silva, Felipe Carneiro; Torrezan, Giovana Tardin; Brianese, Rafael Canfield; Stabellini, Raquel; Carraro, Dirce Maria
2017-07-01
Hereditary breast and ovarian cancer is characterized by mutations in BRCA1 or BRCA2 genes and PCR-based screening techniques, such as capillary sequencing and next-generation sequencing (NGS), are considered gold standard methods for detection of pathogenic mutations in these genes. Single-nucleotide polymorphisms (SNPs) constitute a vast source of variation in the human genome and represent a risk for misdiagnosis in genetic testing, since the presence of a SNP in primer-annealing sites may cause false negative results due to allele dropout. However, few reports are available and the frequency of this phenomenon in diagnostic assays remains unknown. In this article, we investigated the causes of a false negative capillary sequencing result in BRCA1 involving a mother-daughter dyad. Using several molecular strategies, including different DNA polymerases, primer redesign, allele-specific PCR and NGS, we established that the initial misdiagnosis was caused by a SNP located in the primer-annealing region, leading to allele dropout of the mutated allele. Assuming that this problem can also occur in any PCR-based method that are widely used in diagnostic settings, the clinical report presented here draws attention for one of the limitations of genetic testing in general, for which medical and laboratory communities need to be aware.
Tuberculosis in HIV-infected South African children with complicated severe acute malnutrition.
Adler, H; Archary, M; Mahabeer, P; LaRussa, P; Bobat, R A
2017-04-01
Academic tertiary referral hospital in Durban, South Africa. To describe the incidence and diagnostic challenges of tuberculosis (TB) in human immunodeficiency virus (HIV) infected children with severe acute malnutrition (SAM). Post-hoc analysis of a randomised controlled trial that enrolled antiretroviral therapy naïve, HIV-infected children with SAM. Trial records and hospital laboratory results were explored for clinical diagnoses and bacteriologically confirmed cases of TB. Negative binomial regression was used to explore associations with confirmed cases of TB, excluding cases where the clinical diagnosis was not supported by microbiological confirmation. Of 82 children enrolled in the study, 21 (25.6%) were diagnosed with TB, with bacteriological confirmation in 8 cases. Sputum sampling (as opposed to gastric washings) was associated with an increased risk of subsequent diagnosis of TB (adjusted relative risk [aRR] 1.134, 95%CI 1.02-1.26). Culture-proven bacterial infection during admission was associated with a reduced risk of TB (aRR 0.856, 95%CI 0.748-0.979), which may reflect false-negative microbiological tests secondary to empiric broad-spectrum antibiotics. TB is common in HIV-infected children with SAM. While microbiological confirmation of the diagnosis is feasible, empiric treatment remains common, possibly influenced by suboptimal testing and false-negative TB diagnostics. Rigorous microbiological TB investigation should be integrated into the programmatic management of HIV and SAM.
Hygiene-therapists could be used to screen for dental caries and periodontal disease.
Richards, Derek
2015-12-01
A purposive sample of large NHS dental practices with a minimum of three surgeries employing at least one hygiene-therapist (HT) was taken. Asymptomatic patients attending for routine checkups who consented to the study underwent a screen by H-T for dental caries and periodontal disease (index test) followed by a screen by a general dental practitioner (reference test). Patients were recruited consecutively. H-Ts and dentists attended a compulsory training day, which covered recruitment, consenting, screening process, calibration using stock photographs and patient record form completion. Diagnostic threshold for caries was any tooth in the patient's mouth that showed evidence of frank cavitation or shadowing and opacity that would indicate dental caries into the dentine. The diagnostic threshold for periodontal disease was any pocket in the patient's mouth where the black-band of a basic periodontal examination (BPE) probe (3.5 to 5.5 mm) partially or totally disappeared (ie BPE code 3). The index test was compared with the reference test to determine true-positive, false-positive, false-negative and true-negative values. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic odds ratios are shown in Table 1. Eighteen hundred and ninety-nine patients consented to dental screening with 996 patients being randomly allocated to see the dentist first and 903 H-T first. The time interval between the index and reference test never exceeded 21 minutes. With the exception of two practices failing to collect data on smoking and dentures there were no missing results regarding the outcome of a positive or negative screening decision. No adverse events were reported. Mean screening time was five min 25 s for H-Ts and four min 26 s for dentists. Dentists identified 668 patients with caries (Prevalence of 0.35) while H-Ts classified 548 positive and correctly identified 1,047 of the 1,231 patients with no caries. Dentists identified 1074 patients with at least one pocket exceeding 3.5 mm in depth. Of these 935 were correctly identified by the H-Ts. For the 825 screened as negative by the dentist H-Ts correctly identified 621. The results suggest that hygiene-therapists could be used to screen for dental caries and periodontal disease. This has important ramifications for service design in public-funded health systems.
Ojeda-Jiménez, J; Méndez-Ojeda, M M; Martín-Vélez, P; Tejero-García, S; Pais-Brito, J L; Herrera-Pérez, M
2018-03-20
The indiscriminate practice of radiographs for foot and ankle injuries is not justified and numerous studies have corroborated the usefulness of clinical screening tests such as the Ottawa Ankle Rules. The aim of our study is to clinically validate the so-called Shetty Test in our area. A cross-sectional observational study by applying the Shetty test to patients seen in the Emergency Department. We enrolled 100 patients with an average age of 39.25 (16-86). The Shetty test was positive on 14 occasions. Subsequent radiography revealed a fracture in 10 cases: 4 were false positives. The test was negative in the remaining 86 patients and radiography confirmed the absence of fracture (with sensitivity of 100% and specificity of 95.56%, positive predictive value of 71.40%, and negative predictive value of 100%). The Shetty test is a valid clinical screening tool to decide whether simple radiography is indicated for foot and ankle injuries. It is a simple, quick and reproducible test. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
The psychological impact of a false-positive screening mammogram in Barcelona.
Espasa, Rebecca; Murta-Nascimento, Cristiane; Bayés, Ramón; Sala, Maria; Casamitjana, Montserrat; Macià, Francesc; Castells, Xavier
2012-12-01
The purpose of this study was to ascertain the psychological impact of mammographic screening for women who receive negative results and for those who need additional non-invasive and invasive complementary investigations to exclude breast cancer (false positives). One hundred fifty women who attended a breast cancer screening programme in Barcelona, aged 50-69 years, were included in this study: 50 with negative results and 100 with false positive mammograms (50 underwent non-invasive and 50 underwent invasive complementary investigations). Participants worried little until they underwent mammography, but worries increased when a telephone call notified the women of the need for further testing. A substantial proportion of women requiring further assessment reported that they were at least somewhat worried about having breast cancer throughout the screening process (P < 0.0001). Nevertheless, levels of anxiety and depression, measured by the Hospital Anxiety and Depression Scale, showed no statistically significant differences among the three groups. In conclusion, although the women showed no psychological morbidity, there is a substantial psychological response in those with an abnormal screening mammogram.
Krogulski, A
1994-01-01
Among the contaminants of water, soil and air the number of mutagenic and carcinogenic substances is increasing. For the assessment of health risk connected with the simple and cheap methods are necessary which could detected and measure the mutagenicity of these substances. The widely used tests using prokaryotes give negative results in the tests of certain substances which are carcinogenic in mammals. In the case of benzene and acetaldehyde Ames test gives false negative results, and in the case of formaldehyde the results are equivocal. An advantage of fruit fly Drosophila melanogaster used for this purpose is that its cell structures, enzymes and metabolic processes are similar to those of mammals. For the demonstration of mutagenicity of benzene, acetaldehyde and formaldehyde the test of somatic mutation and recombination SMART was carried out in these flies. The results confirmed the usefulness of the SMART test for the demonstration of the mutagenicity of contaminants in the environment.
Classification of HCV and HIV-1 Sequences with the Branching Index
Hraber, Peter; Kuiken, Carla; Waugh, Mark; Geer, Shaun; Bruno, William J.; Leitner, Thomas
2009-01-01
SUMMARY Classification of viral sequences should be fast, objective, accurate, and reproducible. Most methods that classify sequences use either pairwise distances or phylogenetic relations, but cannot discern when a sequence is unclassifiable. The branching index (BI) combines distance and phylogeny methods to compute a ratio that quantifies how closely a query sequence clusters with a subtype clade. In the hypothesis-testing framework of statistical inference, the BI is compared with a threshold to test whether sufficient evidence exists for the query sequence to be classified among known sequences. If above the threshold, the null hypothesis of no support for the subtype relation is rejected and the sequence is taken as belonging to the subtype clade with which it clusters on the tree. This study evaluates statistical properties of the branching index for subtype classification in HCV and HIV-1. Pairs of BI values with known positive and negative test results were computed from 10,000 random fragments of reference alignments. Sampled fragments were of sufficient length to contain phylogenetic signal that groups reference sequences together properly into subtype clades. For HCV, a threshold BI of 0.71 yields 95.1% agreement with reference subtypes, with equal false positive and false negative rates. For HIV-1, a threshold of 0.66 yields 93.5% agreement. Higher thresholds can be used where lower false positive rates are required. In synthetic recombinants, regions without breakpoints are recognized accurately; regions with breakpoints do not uniquely represent any known subtype. Web-based services for viral subtype classification with the branching index are available online. PMID:18753218
The Positive and Negative Effects of Science Concept Tests on Student Conceptual Understanding
NASA Astrophysics Data System (ADS)
Chang, Chun-Yen; Yeh, Ting-Kuang; Barufaldi, James P.
2010-01-01
This study explored the phenomenon of testing effect during science concept assessments, including the mechanism behind it and its impact upon a learner's conceptual understanding. The participants consisted of 208 high school students, in either the 11th or 12th grade. Three types of tests (traditional multiple-choice test, correct concept test, and incorrect concept test) related to the greenhouse effect and global warming were developed to explore the mechanisms underlining the test effect. Interview data analyzed by means of the flow-map method were used to examine the two-week post-test consequences of taking one of these three tests. The results indicated: (1) Traditional tests can affect participants' long-term memory, both positively and negatively; in addition, when students ponder repeatedly and think harder about highly distracting choices during a test, they may gradually develop new conceptions; (2) Students develop more correct conceptions when more true descriptions are provided on the tests; on the other hand, students develop more misconceptions while completing tests in which more false descriptions of choices are provided. Finally, the results of this study revealed a noteworthy phenomenon that tests, if employed appropriately, may be also an effective instrument for assisting students' conceptual understanding.
Influence of various factors on the accuracy of gallium-67 imaging for occult infection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maderazo, E.G.; Hickingbotham, N.B.; Woronick, C.L.
1988-05-01
To examine whether the results and interpretation of gallium-67 citrate imaging may be adversely influenced by factors present in compromised patients, we reviewed our 1-year experience in 69 patients in intensive care units, renal transplants, and those on hemodialysis. Our results indicate that it is an inappropriate diagnostic procedure for acute pancreatitis since seven of nine had false-negative results. Using loglinear modeling and chi-square analysis we found that treatment with antiinflammatory steroids, severe liver disease, end-stage renal disease, and renal transplantation with immunosuppressive therapy did not interfere with gallium-67 uptake. Increased rate of true-negative results in patients with end-stage renalmore » disease was due to a greater and earlier use of the test in the febrile transplant patient and in hemodialysis patients with infections not amenable to diagnosis with gallium-67 scan (transient bacteremia and bacteriuria). We conclude that gallium-67 imaging is a useful diagnostic tool that, with the exception of acute pancreatitis, has very few false-negative results.« less
van der Wilden, Gwendolyn M; Van der Wilden, Gwen; Albers, Christoph E; Albers, Christof; Haefeli, Pascal C; Haefeli, Peter; Zimmermann, Heinz; Zimmerman, Heinz; Exadaktylos, Aristomenis; Exadaktylos, Aris; Levy, Phillip; Birkhan, Oscar; Birkham, Oscar; Michaildou, Maria; Michailidou, Maria; Sideris, Antonios; Velmahos, George C; Velmahos, George; Alam, Hasan B; Alam, Hasan; King, David R; King, David; Fagenholz, Peter J; Fagenholz, Peter; Yeh, D Dante; Yeh, Dante; de Moya, Marc A
2012-12-01
Pneumothoraces (PTXs) are a common entity in thoracic trauma. Micropower impulse radar (MIR) has been able to detect PTXs in surgical patients. However, this technology has not been tested previously on trauma patients. The purpose of this study was to determine the sensitivity and specificity of MIR to detect clinically significant PTXs. We hypothesized that MIR technology can effectively screen trauma patients for clinically significant PTXs. This was a prospective observational study in Level I trauma centers in Boston, Massachusetts, and Bern, Switzerland. All trauma patients undergoing a chest computed tomographic (CT) scan were eligible for the study. Consent was obtained, and readings were performed within 30 minutes before or after the CT scan. The patients had eight lung fields tested (four on each side). The qualitative and quantitative MIR results were blinded and stored on the device. We then compared the results of the MIR to the CT scan and the need for chest tube drainage. We defined PTXs as clinically significant if they required a chest tube. Seventy-five patients were enrolled, with a mean age of 46 ± 16 years. Eighty-four percent were male. The screening test took approximately 1 minute. All but two patients had blunt chest trauma. Six true-positives, 6 false-positives, 63 true-negatives, and 0 false-negatives resulted in an overall sensitivity of 100%. MIR is an easy to use handheld technology that effectively screened patients for clinically significant PTXs, with a sensitivity and negative predictive value of 100%. MIR may be used for rapid, repeatable, and ongoing surveillance of trauma patients. Diagnostic study, level III.
Graff, L; Russell, J; Seashore, J; Tate, J; Elwell, A; Prete, M; Werdmann, M; Maag, R; Krivenko, C; Radford, M
2000-11-01
To test the hypothesis that physician errors (failure to diagnose appendicitis at initial evaluation) correlate with adverse outcome. The authors also postulated that physician errors would correlate with delays in surgery, delays in surgery would correlate with adverse outcomes, and physician errors would occur on patients with atypical presentations. This was a retrospective two-arm observational cohort study at 12 acute care hospitals: 1) consecutive patients who had an appendectomy for appendicitis and 2) consecutive emergency department abdominal pain patients. Outcome measures were adverse events (perforation, abscess) and physician diagnostic performance (false-positive decisions, false-negative decisions). The appendectomy arm of the study included 1, 026 patients with 110 (10.5%) false-positive decisions (range by hospital 4.7% to 19.5%). Of the 916 patients with appendicitis, 170 (18.6%) false-negative decisions were made (range by hospital 10.6% to 27.8%). Patients who had false-negative decisions had increased risks of perforation (r = 0.59, p = 0.058) and of abscess formation (r = 0.81, p = 0.002). For admitted patients, when the inhospital delay before surgery was >20 hours, the risk of perforation was increased [2.9 odds ratio (OR) 95% CI = 1.8 to 4.8]. The amount of delay from initial physician evaluation until surgery varied with physician diagnostic performance: 7.0 hours (95% CI = 6.7 to 7.4) if the initial physician made the diagnosis, 72.4 hours (95% CI = 51.2 to 93.7) if the initial office physician missed the diagnosis, and 63.1 hours (95% CI = 47.9 to 78.4) if the initial emergency physician missed the diagnosis. Patients whose diagnosis was initially missed by the physician had fewer signs and symptoms of appendicitis than patients whose diagnosis was made initially [appendicitis score 2.0 (95% CI = 1.6 to 2.3) vs 6.5 (95% CI = 6.4 to 6.7)]. Older patients (>41 years old) had more false-negative decisions and a higher risk of perforation or abscess (3.5 OR 95% CI = 2.4 to 5.1). False-positive decisions were made for patients who had signs and symptoms similar to those of appendicitis patients [appendicitis score 5.7 (95% CI = 5.2 to 6.1) vs 6.5 (95% CI = 6.4 to 6.7)]. Female patients had an increased risk of false-positive surgery (2.3 OR 95% CI = 1.5 to 3.4). The abdominal pain arm of the study included 1,118 consecutive patients submitted by eight hospitals, with 44 patients having appendicitis. Hospitals with observation units compared with hospitals without observation units had a higher "rule out appendicitis" evaluation rate [33.7% (95% CI = 27 to 38) vs 24.7% (95% CI = 23 to 27)] and a similar hospital admission rate (27.6% vs 24.7%, p = NS). There was a lower miss-diagnosis rate (15.1% vs 19.4%, p = NS power 0.02), lower perforation rate (19.0% vs 20.6%, p = NS power 0.05), and lower abscess rate (5.6% vs 6.9%, p = NS power 0.06), but these did not reach statistical significance. Errors in physician diagnostic decisions correlated with patient clinical findings, i.e., the missed diagnoses were on appendicitis patients with few clinical findings and unnecessary surgeries were on non-appendicitis patients with clinical findings similar to those of patients with appendicitis. Adverse events (perforation, abscess formation) correlated with physician false-negative decisions.
Bartels, Stephan; Schipper, Elisa; Hasemeier, Britta; Kreipe, Hans; Lehmann, Ulrich
2018-05-27
The detection of hotspot mutations in key cancer genes is now an essential part of the diagnostic work-up in molecular pathology. Nearly all assays for mutation detection involve an amplification step. A second single nucleotide variant (SNV) on the same allele adjacent to a mutational hotspot can interfere with primer binding, leading to unnoticed allele-specific amplification of the wild type allele and thereby false-negative mutation testing. We present two diagnostic cases with false negative sequence results for JAK2 and SRSF2. In both cases mutations would have escaped detection if only one strand of DNA had been analysed. Because many commercially available diagnostic kits rely on the analysis of only one DNA strand they are prone to fail in cases like these. Detailed protocols and quality control measures to prevent corresponding pitfalls are presented. Copyright © 2017. Published by Elsevier Inc.
Schlain, Brian; Amaravadi, Lakshmi; Donley, Jean; Wickramasekera, Ananda; Bennett, Donald; Subramanyam, Meena
2010-01-31
In recent years there has been growing recognition of the impact of anti-drug or anti-therapeutic antibodies (ADAs, ATAs) on the pharmacokinetic and pharmacodynamic behavior of the drug, which ultimately affects drug exposure and activity. These anti-drug antibodies can also impact safety of the therapeutic by inducing a range of reactions from hypersensitivity to neutralization of the activity of an endogenous protein. Assessments of immunogenicity, therefore, are critically dependent on the bioanalytical method used to test samples, in which a positive versus negative reactivity is determined by a statistically derived cut point based on the distribution of drug naïve samples. For non-normally distributed data, a novel gamma-fitting method for obtaining assay cut points is presented. Non-normal immunogenicity data distributions, which tend to be unimodal and positively skewed, can often be modeled by 3-parameter gamma fits. Under a gamma regime, gamma based cut points were found to be more accurate (closer to their targeted false positive rates) compared to normal or log-normal methods and more precise (smaller standard errors of cut point estimators) compared with the nonparametric percentile method. Under a gamma regime, normal theory based methods for estimating cut points targeting a 5% false positive rate were found in computer simulation experiments to have, on average, false positive rates ranging from 6.2 to 8.3% (or positive biases between +1.2 and +3.3%) with bias decreasing with the magnitude of the gamma shape parameter. The log-normal fits tended, on average, to underestimate false positive rates with negative biases as large a -2.3% with absolute bias decreasing with the shape parameter. These results were consistent with the well known fact that gamma distributions become less skewed and closer to a normal distribution as their shape parameters increase. Inflated false positive rates, especially in a screening assay, shifts the emphasis to confirm test results in a subsequent test (confirmatory assay). On the other hand, deflated false positive rates in the case of screening immunogenicity assays will not meet the minimum 5% false positive target as proposed in the immunogenicity assay guidance white papers. Copyright 2009 Elsevier B.V. All rights reserved.
False memory in aging: effects of emotional valence on word recognition accuracy.
Piguet, Olivier; Connally, Emily; Krendl, Anne C; Huot, Jessica R; Corkin, Suzanne
2008-06-01
Memory is susceptible to distortions. Valence and increasing age are variables known to affect memory accuracy and may increase false alarm production. Interaction between these variables and their impact on false memory was investigated in 36 young (18-28 years) and 36 older (61-83 years) healthy adults. At study, participants viewed lists of neutral words orthographically related to negative, neutral, or positive critical lures (not presented). Memory for these words was subsequently tested with a remember-know procedure. At test, items included the words seen at study and their associated critical lures, as well as sets of orthographically related neutral words not seen at study and their associated unstudied lures. Positive valence was shown to have two opposite effects on older adults' discrimination of the lures: It improved correct rejection of unstudied lures but increased false memory for critical lures (i.e., lures associated with words studied previously). Thus, increased salience triggered by positive valence may disrupt memory accuracy in older adults when discriminating among similar events. These findings likely reflect a source memory deficit due to decreased efficiency in cognitive control processes with aging.
Accelerated Test Method for Corrosion Protective Coatings Project
NASA Technical Reports Server (NTRS)
Falker, John; Zeitlin, Nancy; Calle, Luz
2015-01-01
This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.
Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun
2018-06-01
Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P < .05). The diagnostic accuracy was best in nodules of 5 to 10 mm in diameter. The sensitivity, accuracy, PPV, and LR for negative US-guided FNA results were better in nodules with a size range of 5 to 15 mm. The specificity, negative predictive value (NPV), and LR for positive results and the Youden index rose with increasing nodule size. Seventeen false-positive and 60 false-negative results were found in this study. The false-negative rate rose with increasing nodule size. However, the false-positive rate was highest in the group containing the smallest nodules. Nodules with circumscribed margins and those that were nonsolid and nonhypoechoic and had no microcalcifications correlated with Bethesda I FNA results. Nodules with circumscribed margins and those that were nonsolid, heterogeneous, and nonhypoechoic and had increased vascularity correlated with false-negative FNA results. Borders correlated with Bethesda I false-negative and false-positive FNA results. Tiny nodules (≤5 mm) with obscure borders tended to yield false-positive FNA results. Large nodules (>20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.
Effects of hydrocortisone on false memory recognition in healthy men and women.
Duesenberg, Moritz; Weber, Juliane; Schaeuffele, Carmen; Fleischer, Juliane; Hellmann-Regen, Julian; Roepke, Stefan; Moritz, Steffen; Otte, Christian; Wingenfeld, Katja
2016-12-01
Most of the studies focusing on the effect of stress on false memories by using psychosocial and physiological stressors yielded diverse results. In the present study, we systematically tested the effect of exogenous hydrocortisone using a false memory paradigm. In this placebo-controlled study, 37 healthy men and 38 healthy women (mean age 24.59 years) received either 10 mg of hydrocortisone or placebo 75 min before using the false memory, that is, Deese-Roediger-McDermott (DRM), paradigm. We used emotionally charged and neutral DRM-based word lists to look for false recognition rates in comparison to true recognition rates. Overall, we expected an increase in false memory after hydrocortisone compared to placebo. No differences between the cortisol and the placebo group were revealed for false and for true recognition performance. In general, false recognition rates were lower compared to true recognition rates. Furthermore, we found a valence effect (neutral, positive, negative, disgust word stimuli), indicating higher rates of true and false recognition for emotional compared to neutral words. We further found an interaction effect between sex and recognition. Post hoc t tests showed that for true recognition women showed a significantly better memory performance than men, independent of treatment. This study does not support the hypothesis that cortisol decreases the ability to distinguish between old versus novel words in young healthy individuals. However, sex and emotional valence of word stimuli appear to be important moderators. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
The role of ultrasound in the management and diagnosis of infectious mononucleosis
2014-01-01
Currently, infectious mononucleosis (IM) is a clinically diagnosed condition. According to the American Family Physician criteria for IM, splenomegaly is the key factor that distinguishes IM from other causes of sore throat. Though heterophile antibody tests are often ordered to confirm diagnosis of IM, this test has a high false-negative rate early in the course of the disease. This case report provides an example of how the use of ultrasound to diagnose splenomegaly and subsequently mononucleosis increases diagnostic accuracy. PMID:24580968
Pina, Géraldine; Dubois, Séverine; Murat, Arnaud; Berger, Nicole; Niccoli, Patricia; Peix, Jean-Louis; Cohen, Régis; Guillausseau, Claudine; Charrie, Anne; Chabre, Olivier; Cornu, Catherine; Borson-Chazot, Françoise; Rohmer, Vincent
2013-03-01
To evaluate a second-generation assay for basal serum calcitonin (CT) measurements compared with the pentagastrin-stimulation test for the diagnosis of inherited medullary thyroid carcinoma (MTC) and the follow-up of patients with MTC after surgery. Recent American Thyroid Association recommendations suggest the use of basal CT alone to diagnose and assess follow-up of MTC as the pentagastrin (Pg) test is unavailable in many countries. Multicentric prospective study. A total of 162 patients with basal CT <10 ng/l were included: 54 asymptomatic patients harboured noncysteine 'rearranged during transfection' (RET) proto-oncogene mutations and 108 patients had entered follow-up of MTC after surgery. All patients underwent basal and Pg-stimulated CT measurements using a second-generation assay with 5-ng/l functional sensitivity. Ninety-five per cent of patients with basal CT ≥ 5 ng/l and 25% of patients with basal CT <5 ng/l had a positive Pg-stimulation test (Pg CT >10 ng/l). Compared with the reference Pg test, basal CT ≥ 5 ng/l had 99% specificity, a 95%-positive predictive value but only 35% sensitivity (P < 0.0001). Overall, there were 31% less false-negative results using a 5-ng/l threshold for basal CT instead of the previously used 10-ng/l threshold. The ultrasensitive CT assay reduces the false-negative rate of basal CT measurements when diagnosing familial MTC and in postoperative follow-up compared with previously used assays. However, its sensitivity to detect C-cell disease remains lower than that of the Pg-stimulation test. © 2012 Blackwell Publishing Ltd.
Cheng, Hong; Macaluso, Maurizio; Vermund, Sten H.; Hook, Edward W.
2001-01-01
Published estimates of the sensitivity and specificity of PCR and ligase chain reaction (LCR) for detecting Chlamydia trachomatis are potentially biased because of study design limitations (confirmation of test results was limited to subjects who were PCR or LCR positive but culture negative). Relative measures of test accuracy are less prone to bias in incomplete study designs. We estimated the relative sensitivity (RSN) and relative false-positive rate (RFP) for PCR and LCR versus cell culture among 1,138 asymptomatic men and evaluated the potential bias of RSN and RFP estimates. PCR and LCR testing in urine were compared to culture of urethral specimens. Discordant results (PCR or LCR positive, but culture negative) were confirmed by using a sequence including the other DNA amplification test, direct fluorescent antibody testing, and a DNA amplification test to detect chlamydial major outer membrane protein. The RSN estimates for PCR and LCR were 1.45 (95% confidence interval [CI] = 1.3 to 1.7) and 1.49 (95% CI = 1.3 to 1.7), respectively, indicating that both methods are more sensitive than culture. Very few false-positive results were found, indicating that the specificity levels of PCR, LCR, and culture are high. The potential bias in RSN and RFP estimates were <5 and <20%, respectively. The estimation of bias is based on the most likely and probably conservative parameter settings. If the sensitivity of culture is between 60 and 65%, then the true sensitivity of PCR and LCR is between 90 and 97%. Our findings indicate that PCR and LCR are significantly more sensitive than culture, while the three tests have similar specificities. PMID:11682509
Malaria rapid diagnostic tests in endemic settings.
Maltha, J; Gillet, P; Jacobs, J
2013-05-01
Malaria rapid diagnostic tests (RDTs) are instrument-free tests that provide results within 20 min and can be used by community health workers. RDTs detect antigens produced by the Plasmodium parasite such as Plasmodium falciparum histidine-rich protein-2 (PfHPR2) and Plasmodium lactate dehydrogenase (pLDH). The accuracy of RDTs for the diagnosis of uncomplicated P. falciparum infection is equal or superior to routine microscopy (but inferior to expert microscopy). Sensitivity for Plasmodium vivax is 75-100%; for Plasmodium ovale and Plasmodium malariae, diagnostic performance is poor. Design limitations of RDTs include poor sensitivity at low parasite densities, susceptibility to the prozone effect (PfHRP2-detecting RDTs), false-negative results due to PfHRP2 deficiency in the case of pfhrp2 gene deletions (PfHRP2-detecting RDTs), cross-reactions between Plasmodium antigens and detection antibodies, false-positive results by other infections and susceptibility to heat and humidity. End-user's errors relate to safety, procedure (delayed reading, incorrect sample and buffer volumes) and interpretation (not recognizing invalid test results, disregarding faint test lines). Withholding antimalarial treatment in the case of negative RDT results tends to be infrequent and tendencies towards over-prescription of antibiotics have been noted. Numerous shortcomings in RDT kits' labelling, instructions for use (correctness and readability) and contents have been observed. The World Health Organization and partners actively address quality assurance of RDTs by comparative testing of RDTs, inspections of manufacturing sites, lot testing and training tools but no formal external quality assessment programme of end-user performance exists. Elimination of malaria requires RDTs with lower detection limits, for which nucleic acid amplification tests are under development. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.
[Primary cervical cancer screening].
Vargas-Hernández, Víctor Manuel; Vargas-Aguilar, Víctor Manuel; Tovar-Rodríguez, José María
2015-01-01
Cervico-uterine cancer screening with cytology decrease incidence by more than 50%. The cause of this cancer is the human papilloma virus high risk, and requires a sensitive test to provide sufficient sensitivity and specificity for early detection and greater interval period when the results are negative. The test of the human papilloma virus high risk, is effective and safe because of its excellent sensitivity, negative predictive value and optimal reproducibility, especially when combined with liquid-based cytology or biomarkers with viral load, with higher sensitivity and specificity, by reducing false positives for the detection of cervical intraepithelial neoplasia grade 2 or greater injury, with excellent clinical benefits to cervical cancer screening and related infection of human papilloma virus diseases, is currently the best test for early detection infection of human papillomavirus and the risk of carcinogenesis. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.
False memories and memory confidence in borderline patients.
Schilling, Lisa; Wingenfeld, Katja; Spitzer, Carsten; Nagel, Matthias; Moritz, Steffen
2013-12-01
Mixed results have been obtained regarding memory in patients with borderline personality disorder (BPD). Prior reports and anecdotal evidence suggests that patients with BPD are prone to false memories but this assumption has to been put to firm empirical test, yet. Memory accuracy and confidence was assessed in 20 BPD patients and 22 healthy controls using a visual variant of the false memory (Deese-Roediger-McDermott) paradigm which involved a negative and a positive-valenced picture. Groups did not differ regarding veridical item recognition. Importantly, patients did not display more false memories than controls. At trend level, borderline patients rated more items as new with high confidence compared to healthy controls. The results tentatively suggest that borderline patients show uncompromised visual memory functions and display no increased susceptibility for distorted memories. Copyright © 2013 Elsevier Ltd. All rights reserved.
Sentinel lymph node mapping in melanoma: the issue of false-negative findings.
Manca, Gianpiero; Rubello, Domenico; Romanini, Antonella; Boni, Giuseppe; Chiacchio, Serena; Tredici, Manuel; Mazzarri, Sara; Duce, Valerio; Colletti, Patrick M; Volterrani, Duccio; Mariani, Giuliano
2014-07-01
Management of cutaneous melanoma has changed after introduction in the clinical routine of sentinel lymph node biopsy (SLNB) for nodal staging. By defining the nodal basin status, SLNB provides a powerful prognostic information. Nevertheless, some debate still surrounds the accuracy of this procedure in terms of false-negative rate. Several large-scale studies have reported a relatively high false-negative rate (5.6%-21%), correctly defined as the proportion of false-negative results with respect to the total number of "actual" positive lymph nodes. In this review, we identified all the technical aspects that the nuclear medicine physician, the surgeon, and the pathologist should take into account to improve accuracy of the procedure and minimize the false-negative rate. In particular, SPECT/CT imaging detects more SLNs than those found by planar lymphoscintigraphy. Furthermore, the nuclear medicine community should reach a consensus on the radioactive counting rate threshold to better guide the surgeon in identifying the lymph nodes with the highest likelihood of housing metastases ("true biologic SLNs"). Analysis of the harvested SLNs by conventional techniques is also a further potential source for error. More accurate SLN analysis (eg, molecular analysis by reverse transcriptase-polymerase chain reaction) and more extensive SLN sampling identify more positive nodes, thus reducing the false-negative rate.The clinical factors identifying patients at higher-risk local recurrence after a negative SLNB include older age at diagnosis, deeper lesions, histological ulceration, and head-neck anatomic location of the primary lesion.The clinical impact of a false-negative SLNB on the prognosis of melanoma patients remains controversial, because the majority of studies have failed to demonstrate overall statistically significant disadvantage in melanoma-specific survival for false-negative SLNB patients compared with true-positive SLNB patients.When new more effective drugs will be available in the adjuvant setting for stage III melanoma patients, the implication of an accurate staging procedure for the sentinel lymph nodes will be crucial for both patients and clinicians. Standardization and accuracy of SLN identification, removal, and analysis are required.
Global Sensitivity Analysis with Small Sample Sizes: Ordinary Least Squares Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Michael J.; Liu, Wei; Sivaramakrishnan, Raghu
2016-12-21
A new version of global sensitivity analysis is developed in this paper. This new version coupled with tools from statistics, machine learning, and optimization can devise small sample sizes that allow for the accurate ordering of sensitivity coefficients for the first 10-30 most sensitive chemical reactions in complex chemical-kinetic mechanisms, and is particularly useful for studying the chemistry in realistic devices. A key part of the paper is calibration of these small samples. Because these small sample sizes are developed for use in realistic combustion devices, the calibration is done over the ranges of conditions in such devices, with amore » test case being the operating conditions of a compression ignition engine studied earlier. Compression ignition engines operate under low-temperature combustion conditions with quite complicated chemistry making this calibration difficult, leading to the possibility of false positives and false negatives in the ordering of the reactions. So an important aspect of the paper is showing how to handle the trade-off between false positives and false negatives using ideas from the multiobjective optimization literature. The combination of the new global sensitivity method and the calibration are sample sizes a factor of approximately 10 times smaller than were available with our previous algorithm.« less
Stress and emotional valence effects on children's versus adolescents' true and false memory.
Quas, Jodi A; Rush, Elizabeth B; Yim, Ilona S; Edelstein, Robin S; Otgaar, Henry; Smeets, Tom
2016-01-01
Despite considerable interest in understanding how stress influences memory accuracy and errors, particularly in children, methodological limitations have made it difficult to examine the effects of stress independent of the effects of the emotional valence of to-be-remembered information in developmental populations. In this study, we manipulated stress levels in 7-8- and 12-14-year-olds and then exposed them to negative, neutral, and positive word lists. Shortly afterward, we tested their recognition memory for the words and false memory for non-presented but related words. Adolescents in the high-stress condition were more accurate than those in the low-stress condition, while children's accuracy did not differ across stress conditions. Also, among adolescents, accuracy and errors were higher for the negative than positive words, while in children, word valence was unrelated to accuracy. Finally, increases in children's and adolescents' cortisol responses, especially in the high-stress condition, were related to greater accuracy but not false memories and only for positive emotional words. Findings suggest that stress at encoding, as well as the emotional content of to-be-remembered information, may influence memory in different ways across development, highlighting the need for greater complexity in existing models of true and false memory formation.
Jing, Chang-Wen; Wang, Zhuo; Cao, Hai-Xia; Ma, Rong; Wu, Jian-Zhong
2014-01-01
The aim of the research was to explore a cost effective, fast, easy to perform, and sensitive method for epidermal growth factor receptor (EGFR) mutation testing. High resolution melting analysis (HRM) was introduced to evaluate the efficacy of the analysis for dectecting EGFR mutations in exons 18 to 21 using formalin-fixed paraffin-embedded (FFPE) tissues and plasma free DNA from 120 patients. The total EGFR mutation rate was 37.5% (45/120) detected by direct sequencing. There were 48 mutations in 120 FFPE tissues assessed by HRM. For plasma free DNA, the EGFR mutation rate was 25.8% (31/120). The sensitivity of HRM assays in FFPE samples was 100% by HRM. There was a low false-positive mutation rate but a high false-negative rate in plasma free DNA detected by HRM. Our results show that HRM analysis has the advantage of small tumor sample need. HRM applied with plasma free DNA showed a high false-negative rate but a low false-positive rate. Further research into appropriate methods and analysis needs to be performed before HRM for plasma free DNA could be accepted as an option in diagnostic or screening settings.
Serological diagnosis of bovine brucellosis using B. melitensis strain B115.
Corrente, Marialaura; Desario, Costantina; Parisi, Antonio; Grandolfo, Erika; Scaltrito, Domenico; Vesco, Gesualdo; Colao, Valeriana; Buonavoglia, Domenico
2015-12-01
Bovine brucellosis is diagnosed by official tests, such as Rose Bengal plate test (RBPT) and Complement Fixation test (CFT). Both tests detect antibodies directed against the lipolysaccharide (LPS) of Brucella cell wall. Despite their good sensitivity, those tests do not discriminate between true positive and false positive serological reactions (FPSR), the latter being generated by animals infected with other Gram negative microorganisms that share components of Brucella LPS. In this study, an antigenic extract from whole Brucella melitensis B115 strain was used to set up an ELISA assay for the serological diagnosis of bovine brucellosis. A total of 148 serum samples from five different groups of animals were tested: Group A: 28 samples from two calves experimentally infected with Yersinia enterocolitica O:9; Group B: 30 samples from bovines infected with Brucella abortus; Group C: 50 samples from brucellosis-free herds; Group D: 20 samples RBPT positive and CFT negative; Group E: 20 samples both RBPT and CFT positive. Group D and Group E serum samples were from brucellosis-free herds. Positive reactions were detected only by RBPT and CFT in calves immunized with Y. enterocolitica O:9. Sera from Group B animals tested positive also in the ELISA assay, whereas sera from the remaining groups were all negative. The results obtained encourage the use of the ELISA assay to implement the serological diagnosis of brucellosis. Copyright © 2015 Elsevier B.V. All rights reserved.
Augmented Cross-Sectional Studies with Abbreviated Follow-up for Estimating HIV Incidence
Claggett, B.; Lagakos, S.W.; Wang, R.
2011-01-01
Summary Cross-sectional HIV incidence estimation based on a sensitive and less-sensitive test offers great advantages over the traditional cohort study. However, its use has been limited due to concerns about the false negative rate of the less-sensitive test, reflecting the phenomenon that some subjects may remain negative permanently on the less-sensitive test. Wang and Lagakos (2010) propose an augmented cross-sectional design which provides one way to estimate the size of the infected population who remain negative permanently and subsequently incorporate this information in the cross-sectional incidence estimator. In an augmented cross-sectional study, subjects who test negative on the less-sensitive test in the cross-sectional survey are followed forward for transition into the nonrecent state, at which time they would test positive on the less-sensitive test. However, considerable uncertainty exists regarding the appropriate length of follow-up and the size of the infected population who remain nonreactive permanently to the less-sensitive test. In this paper, we assess the impact of varying follow-up time on the resulting incidence estimators from an augmented cross-sectional study, evaluate the robustness of cross-sectional estimators to assumptions about the existence and the size of the subpopulation who will remain negative permanently, and propose a new estimator based on abbreviated follow-up time (AF). Compared to the original estimator from an augmented cross-sectional study, the AF Estimator allows shorter follow-up time and does not require estimation of the mean window period, defined as the average time between detectability of HIV infection with the sensitive and less-sensitive tests. It is shown to perform well in a wide range of settings. We discuss when the AF Estimator would be expected to perform well and offer design considerations for an augmented cross-sectional study with abbreviated follow-up. PMID:21668904
Augmented cross-sectional studies with abbreviated follow-up for estimating HIV incidence.
Claggett, B; Lagakos, S W; Wang, R
2012-03-01
Cross-sectional HIV incidence estimation based on a sensitive and less-sensitive test offers great advantages over the traditional cohort study. However, its use has been limited due to concerns about the false negative rate of the less-sensitive test, reflecting the phenomenon that some subjects may remain negative permanently on the less-sensitive test. Wang and Lagakos (2010, Biometrics 66, 864-874) propose an augmented cross-sectional design that provides one way to estimate the size of the infected population who remain negative permanently and subsequently incorporate this information in the cross-sectional incidence estimator. In an augmented cross-sectional study, subjects who test negative on the less-sensitive test in the cross-sectional survey are followed forward for transition into the nonrecent state, at which time they would test positive on the less-sensitive test. However, considerable uncertainty exists regarding the appropriate length of follow-up and the size of the infected population who remain nonreactive permanently to the less-sensitive test. In this article, we assess the impact of varying follow-up time on the resulting incidence estimators from an augmented cross-sectional study, evaluate the robustness of cross-sectional estimators to assumptions about the existence and the size of the subpopulation who will remain negative permanently, and propose a new estimator based on abbreviated follow-up time (AF). Compared to the original estimator from an augmented cross-sectional study, the AF estimator allows shorter follow-up time and does not require estimation of the mean window period, defined as the average time between detectability of HIV infection with the sensitive and less-sensitive tests. It is shown to perform well in a wide range of settings. We discuss when the AF estimator would be expected to perform well and offer design considerations for an augmented cross-sectional study with abbreviated follow-up. © 2011, The International Biometric Society.
Dental pulp neurophysiology: part 2. Current diagnostic tests to assess pulp vitality.
Abd-Elmeguid, Ashraf; Yu, Donald C
2009-03-01
In this second part of our 2-part review, we discuss recent research about pulp tests that determine the vitality of the tooth and clinically accepted pulp testers. A pain response to hot, cold or an electric pulp tester indicates the vitality of only a tooth's pulpal sensory supply; the response does not give any idea about the state of the pulp. Although the sensitivity of these tests is high, when false-positive and false-negative results occur, they may affect the treatment of the tooth. A tooth falsely diagnosed as nonvital with an electric pulp tester may undergo an unnecessary root canal, whereas one falsely diagnosed as vital may be left untreated, causing the necrotic tissue to destroy the supporting tissues (resorption). The vascular supply is more important to the determination of the health of the pulp than the sensory supply. Pulp death is caused by cessation of blood flow and may result in a necrotic pulp, even though the pulpal sensory supply may still be viable. The pulp can be healed only if the circulating blood flow is healthy. Although still under investigation, diagnostic devices that examine pulpal blood flow, such as the pulse oximeter and laser Doppler flowmetry, show promising results for the assessment of pulp vitality.
Chapin, Kimberle C.; Blake, Patricia; Wilson, Claire D.
2002-01-01
Group A streptococcus (GAS) antigen testing has become a routine point-of-care (POC) test in acute care settings. Concern about performance parameters (PP) of these tests as well as inappropriate antibiotic use has resulted in various recommendations regarding diagnosis of GAS. There were two objectives in this study. The first was to evaluate the rapid GAS antigen test presently in use (Thermo BioStar, Boulder, Colo.) and the GAS Direct probe test (Gen-Probe, San Diego, Calif.) compared to culture. The second was to define the optimal use of these technologies in a large acute care pediatric clinic. A total of 520 consecutive pediatric patients presenting with symptoms of pharyngitis at any of three Lahey Clinic acute care facilities were evaluated. Pharyngeal specimens were collected using a double-swab collection device (Copan, Corona, Calif.). One swab was used for the antigen test, the second was used for the probe test, and the pledget was placed in the collection device for culture on 5% sheep blood agar, incubated for 48 h anaerobically, and subsequently placed in Todd-Hewitt broth. After discrepant analysis, sensitivity, specificity, and positive and negative predictive values were as follows: 94.8, 100, 100, and 96.9% for the probe test and 86.1, 97.1, 93.7, and 93.4% for the antigen test, respectively. Sensitivity using an enhanced culture technique was 99.4% (163 of 164). False-positive (FP) antigen results were often seen from patients previously diagnosed and/or treated for GAS. No FP results were seen with the probe test. Colony counts for the false-negative (FN) antigen tests were higher than those for the FN probe tests. Compared to culture and DNA probe, the rapid antigen test (RAT) offered a result at the time of the patient's visit, with acceptable PP when prevalence of disease is high. Follow-up testing with the RAT of GAS patients who previously tested as positive should be avoided due to increased FP results. The probe test was comparable to culture in performance. Results indicate the probe test can be used as the primary test or as a backup to negative antigen tests. The probe test offers the advantage over culture of same-day reporting of a final result but, in contrast to a POC test, necessitates follow-up communication to the patient. Preliminary data show the specificity of the probe test to be greater than that of the RAT for patients previously diagnosed with GAS. PMID:12409399
Measurement error: Implications for diagnosis and discrepancy models of developmental dyslexia.
Cotton, Sue M; Crewther, David P; Crewther, Sheila G
2005-08-01
The diagnosis of developmental dyslexia (DD) is reliant on a discrepancy between intellectual functioning and reading achievement. Discrepancy-based formulae have frequently been employed to establish the significance of the difference between 'intelligence' and 'actual' reading achievement. These formulae, however, often fail to take into consideration test reliability and the error associated with a single test score. This paper provides an illustration of the potential effects that test reliability and measurement error can have on the diagnosis of dyslexia, with particular reference to discrepancy models. The roles of reliability and standard error of measurement (SEM) in classic test theory are also briefly reviewed. This is followed by illustrations of how SEM and test reliability can aid with the interpretation of a simple discrepancy-based formula of DD. It is proposed that a lack of consideration of test theory in the use of discrepancy-based models of DD can lead to misdiagnosis (both false positives and false negatives). Further, misdiagnosis in research samples affects reproducibility and generalizability of findings. This in turn, may explain current inconsistencies in research on the perceptual, sensory, and motor correlates of dyslexia.
More than just T₄: diagnostic testing for hyperthyroidism in cats.
Peterson, Mark E
2013-09-01
In older cats presenting with clinical features of hyperthyroidism, confirmation of a diagnosis of thyroid disease is usually straightforward. However, the potential for false-negative and false-positive results exists with all thyroid function tests (especially in the context of routine screening of asymptomatic cats) and leads to clinical dilemmas. For example, a high serum T₄ value may be found in a cat that lacks clinical signs of hyperthyroidism, or hyperthyroidism may be suspected in a cat with normal total T₄ concentrations. To avoid unnecessary treatment and potentially adverse effects in a euthyroid cat, thyroid function tests must always be interpreted in the light of the cat's history, clinical signs, physical examination findings and other laboratory findings. In this article the author reviews the use of commonly recommended thyroid function tests, focusing on clinical scenarios that present diagnostic difficulties. In doing so, he draws on the veterinary and comparative literature, his own clinical experience, and data, unpublished to date, obtained from a series of 100 hyperthyroid cats consecutively diagnosed at his clinic.
Brown, Charlotte A.; Bogers, Johnannes; Sahebali, Shaira; Depuydt, Christophe E.; De Prins, Frans; Malinowski, Douglas P.
2012-01-01
Since the Pap test was introduced in the 1940s, there has been an approximately 70% reduction in the incidence of squamous cell cervical cancers in many developed countries by the application of organized and opportunistic screening programs. The efficacy of the Pap test, however, is hampered by high interobserver variability and high false-negative and false-positive rates. The use of biomarkers has demonstrated the ability to overcome these issues, leading to improved positive predictive value of cervical screening results. In addition, the introduction of HPV primary screening programs will necessitate the use of a follow-up test with high specificity to triage the high number of HPV-positive tests. This paper will focus on protein biomarkers currently available for use in cervical cancer screening, which appear to improve the detection of women at greatest risk for developing cervical cancer, including Ki-67, p16INK4a, BD ProEx C, and Cytoactiv HPV L1. PMID:22481919
False negative cytology in large thyroid nodules.
Giles, Wesley H; Maclellan, Reid A; Gawande, Atul A; Ruan, Daniel T; Alexander, Erik K; Moore, Francis D; Cho, Nancy L
2015-01-01
Controversy exists regarding the accuracy of fine-needle aspiration (FNA) in large thyroid nodules. Recent surgical series have documented false-negative rates ranging from 0.7 to 13 %. We examined the accuracy of benign FNA cytology in patients with thyroid nodules ≥3 cm who underwent surgical resection and identified features characteristic of false-negative results. We retrospectively studied all thyroidectomy specimens between January 2009 and October 2011 and identified nodules ≥3 cm with corresponding benign preoperative FNA cytology. We collected clinical information regarding patient demographics, nodule size, symptoms, sonographic features, FNA results, and final surgical pathology. For comparison, we analyzed nodules <3 cm from this cohort also with benign FNA cytology. A total of 323 nodules with benign preoperative cytology were identified. Eighty-three nodules were <3 cm, 94 nodules were 3-3.9 cm, and 146 nodules were ≥4 cm in size. The false-negative rate was 11.7 % for all nodules ≥3 cm and 4.8 % for nodules <3 cm (p = 0.03). Subgroup analysis of nodules ≥3 cm revealed a false-negative rate of 12.8 % for nodules 3-3.9 cm and 11 % for nodules ≥4 cm. Age ≥55 years and asymptomatic clinical status were the only patient characteristics that reached statistical significance as risk factors. Final pathology of the false-negative specimens consisted mainly of follicular variant of papillary thyroid cancer and follicular thyroid cancer. When referred for thyroidectomy, patients with large thyroid nodules demonstrate a modest, yet significant, false-negative rate despite initial benign aspiration cytology. Therefore, thyroid nodules ≥3 cm may be considered for removal even when referred with benign preoperative cytology.
Manchikanti, Laxmaiah; Malla, Yogesh; Wargo, Bradley W; Cash, Kimberly A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D; Brandon, Doris E
2010-01-01
Therapeutic use, overuse, abuse, and diversion of controlled substances in managing chronic non-cancer pain continues to be an issue for physicians and patients. It has been stated that physicians, along with the public and federal, state, and local government; professional associations; and pharmaceutical companies all share responsibility for preventing abuse of controlled prescription drugs. The challenge is to eliminate or significantly curtail abuse of controlled prescription drugs while still assuring the proper treatment of those patients. A number of techniques, instruments, and tools have been described to monitor controlled substance use and abuse. Thus, multiple techniques and tools available for adherence monitoring include urine drug testing in conjunction with prescription monitoring programs and other screening tests. However, urine drug testing is associated with multiple methodological flaws. Multiple authors have provided conflicting results in relation to diagnostic accuracy with differing opinions about how to monitor adherence in a non-systematic fashion. Thus far, there have not been any studies systematically assessing the diagnostic accuracy of immunoassay with laboratory testing. A diagnostic accuracy study of urine drug testing. An interventional pain management practice, a specialty referral center, a private practice setting in the United States. To compare the information obtained by point of care (POC) or in-office urine drug testing (index test) to the information found when all drugs and analytes are tested by liquid chromatography tandem mass spectroscopy (LC/MS/MS) reference test in the same urine sample. The study is designed to include 1,000 patients with chronic pain receiving controlled substances. The primary outcome measure is the diagnostic accuracy. Patients will be tested for various controlled substances, including opioids, benzodiazepines, and illicit drugs. The diagnostic accuracy study is performed utilizing the Standards for Reporting of Diagnostic Accuracy Studies (STARD) initiative which established reporting guidelines for diagnostic accuracy studies to improve the quality of reporting. The prototypical flow diagram of diagnostic accuracy study as described by STARD will be utilized. Results of diagnostic accuracy and correlation of clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics will be calculated. The limitations include lack of availability of POC testing with lower cutoff levels. This article presents a protocol for a diagnostic accuracy study of urine drug testing. The protocol also will permit correlation of various clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics. NCT 01052155.
Identification student’s misconception of heat and temperature using three-tier diagnostic test
NASA Astrophysics Data System (ADS)
Suliyanah; Putri, H. N. P. A.; Rohmawati, L.
2018-03-01
The objective of this research is to develop a Three-Tier Diagnostic Test (TTDT) to identify the student's misconception of heat and temperature. Stages of development include: analysis, planning, design, development, evaluation and revise. The results of this study show that (1) the quality of the three-tier type diagnostic test instrument developed has been expressed well with the following details: (a) Internal validity of 88.19% belonging to the valid category. (b) External validity of empirical construct validity test using Pearson Product Moment obtained 0.43 is classified and result of empirical construct validity test obtained false positives 6.1% and false negatives 5.9% then the instrument was valid. (c) Test reliability by using Cronbach’s Alpha of 0.98 which means acceptable. (d) The 80% difficulty level test is quite difficult. (2) Student misconceptions on the temperature of heat and displacement materials based on the II test the highest (84%), the lowest (21%), and the non-misconceptions (7%). (3) The highest cause of misconception among students is associative thinking (22%) and the lowest is caused by incomplete or incomplete reasoning (11%). Three-Tier Diagnostic Test (TTDT) could identify the student's misconception of heat and temperature.
Blanch, Jordi; Sala, Maria; Ibáñez, Josefa; Domingo, Laia; Fernandez, Belén; Otegi, Arantza; Barata, Teresa; Zubizarreta, Raquel; Ferrer, Joana; Castells, Xavier; Rué, Montserrat; Salas, Dolores
2014-01-01
Background Interval cancers are primary breast cancers diagnosed in women after a negative screening test and before the next screening invitation. Our aim was to evaluate risk factors for interval cancer and their subtypes and to compare the risk factors identified with those associated with incident screen-detected cancers. Methods We analyzed data from 645,764 women participating in the Spanish breast cancer screening program from 2000–2006 and followed-up until 2009. A total of 5,309 screen-detected and 1,653 interval cancers were diagnosed. Among the latter, 1,012 could be classified on the basis of findings in screening and diagnostic mammograms, consisting of 489 true interval cancers (48.2%), 235 false-negatives (23.2%), 172 minimal-signs (17.2%) and 114 occult tumors (11.3%). Information on the screening protocol and women's characteristics were obtained from the screening program registry. Cause-specific Cox regression models were used to estimate the hazard ratios (HR) of risks factors for interval cancer and incident screen-detected cancer. A multinomial regression model, using screen-detected tumors as a reference group, was used to assess the effect of breast density and other factors on the occurrence of interval cancer subtypes. Results A previous false-positive was the main risk factor for interval cancer (HR = 2.71, 95%CI: 2.28–3.23); this risk was higher for false-negatives (HR = 8.79, 95%CI: 6.24–12.40) than for true interval cancer (HR = 2.26, 95%CI: 1.59–3.21). A family history of breast cancer was associated with true intervals (HR = 2.11, 95%CI: 1.60–2.78), previous benign biopsy with a false-negatives (HR = 1.83, 95%CI: 1.23–2.71). High breast density was mainly associated with occult tumors (RRR = 4.92, 95%CI: 2.58–9.38), followed by true intervals (RRR = 1.67, 95%CI: 1.18–2.36) and false-negatives (RRR = 1.58, 95%CI: 1.00–2.49). Conclusion The role of women's characteristics differs among interval cancer subtypes. This information could be useful to improve effectiveness of breast cancer screening programmes and to better classify subgroups of women with different risks of developing cancer. PMID:25333936
Reck, Martin; Hagiwara, Koichi; Han, Baohui; Tjulandin, Sergei; Grohé, Christian; Yokoi, Takashi; Morabito, Alessandro; Novello, Silvia; Arriola, Edurne; Molinier, Olivier; McCormack, Rose; Ratcliffe, Marianne; Normanno, Nicola
2016-10-01
To offer patients with EGFR mutation-positive advanced NSCLC appropriate EGFR tyrosine kinase inhibitor treatment, mutation testing of tumor samples is required. However, tissue/cytologic samples are not always available or evaluable. The large, noninterventional diagnostic ASSESS study (NCT01785888) evaluated the utility of circulating free tumor-derived DNA (ctDNA) from plasma for EGFR mutation testing. ASSESS was conducted in 56 centers (in Europe and Japan). Eligible patients (with newly diagnosed locally advanced/metastatic treatment-naive advanced NSCLC) provided diagnostic tissue/cytologic and plasma samples. DNA extracted from tissue/cytologic samples was subjected to EGFR mutation testing using local practices; designated laboratories performed DNA extraction/mutation testing of blood samples. The primary end point was level of concordance of EGFR mutation status between matched tissue/cytologic and plasma samples. Of 1311 patients enrolled, 1288 were eligible. Concordance of mutation status in 1162 matched samples was 89% (sensitivity 46%, specificity 97%, positive predictive value 78%, and negative predictive value 90%). A group of 25 patients with apparent false-positive plasma results was overrepresented for cytologic samples, use of less sensitive tissue testing methodologies, and smoking habits associated with high EGFR mutation frequency, indicative of false-negative tumor results. In cases in which plasma and tumor samples were tested with identical highly sensitive methods, positive predictive value/sensitivity were generally improved. These real-world data suggest that ctDNA is a feasible sample for EGFR mutation analysis. It is important to conduct mutation testing of both tumor and plasma samples in specialized laboratories, using robust/sensitive methods to ensure that patients receive appropriate treatments that target the molecular features of their disease. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.
A statistical model of false negative and false positive detection of phase singularities.
Jacquemet, Vincent
2017-10-01
The complexity of cardiac fibrillation dynamics can be assessed by analyzing the distribution of phase singularities (PSs) observed using mapping systems. Interelectrode distance, however, limits the accuracy of PS detection. To investigate in a theoretical framework the PS false negative and false positive rates in relation to the characteristics of the mapping system and fibrillation dynamics, we propose a statistical model of phase maps with controllable number and locations of PSs. In this model, phase maps are generated from randomly distributed PSs with physiologically-plausible directions of rotation. Noise and distortion of the phase are added. PSs are detected using topological charge contour integrals on regular grids of varying resolutions. Over 100 × 10 6 realizations of the random field process are used to estimate average false negative and false positive rates using a Monte-Carlo approach. The false detection rates are shown to depend on the average distance between neighboring PSs expressed in units of interelectrode distance, following approximately a power law with exponents in the range of 1.14 to 2 for false negatives and around 2.8 for false positives. In the presence of noise or distortion of phase, false detection rates at high resolution tend to a non-zero noise-dependent lower bound. This model provides an easy-to-implement tool for benchmarking PS detection algorithms over a broad range of configurations with multiple PSs.
Watterson, Jeannette M; Stallcup, Paulina; Escamilla, David; Chernay, Patrick; Reyes, Alfred; Trevino, Sylvia C
2007-01-01
After observing a high incidence of low positive hepatitis C virus (HCV) antibody screens by the Ortho-Clinical Vitros ECi test (Orthoclinical Diagnostics, Raritan, NJ), we compared results against those obtained using another chemiluminescent analyzer, as well as two U.S. Food and Drug Administration (FDA)-approved confirmatory methodologies. To ascertain the true anti-HCV status of samples deemed low-positive by the Ortho-Clinical Vitros ECi test, we tested samples using the ADVIA Centaur HCV screen test (Siemens Medical Solutions Diagnostics), the Chiron recombinant immunoblot assay (RIBA) test (Chiron Corp., Emeryville, CA), and the Roche COBAS Amplicor HCV qualitative test (Roche Diagnostics, Indianapolis, IN) in a series of studies. Of 94 specimens positive by Vitros ECi, 19% were observed to be negative by Centaur. A separate study of 91 samples with signal-to-cutoff (s/co) values less than 8.0 showed that all but one was negative for HCV ribonucleic acid (RNA). In comparison with RIBA, 100% (77) samples positive by the Vitros ECi test with s/co values less than 12.0 were negative or indeterminate by RIBA. A final study comparing all four methods side-by-side showed 63% disagreement by Centaur for Vitros ECi low-positive samples, 75% disagreement by RIBA, and 97% disagreement by polymerase chain reaction (PCR). In conclusion, the Ortho-Clinical Vitros ECi Anti-HCV test yields a high rate of false-positive results in the low s/co range in our patient population. (c) 2007 Wiley-Liss, Inc.
Feberwee, A; Mekkes, D R; de Wit, J J; Hartman, E G; Pijpers, A
2005-06-01
In this study, the technical performance of culture, two commercially available polymerase chain reaction (PCR) tests, rapid plate agglutination (RPA) test, hemagglutination inhibition (HI) test, and eight commercially available enzyme-linked immunosorbent assays (ELISAs) were compared for the detection of avian mycoplasma infections from 3 days postinfection (d.p.i.) through 35 d.p.i. The tests were carried out on samples from specified pathogen-free layers that were infected at 66 wk of age with recent Mycoplasma synoviae (MS) and Mycoplasma gallisepticum (MG) field strains, MS and MG ATCC strains, and Mycoplasma imitans (MIM), respectively. Results showed a high percentage of positive samples in the homologous infected groups and a high percentage of negative samples (100%) in the uninfected and heterologous infected groups during 35 d.p.i. of both culture and PCR tests. For the group infected with the MG 15302 ATCC strain, serology was more sensitive than bacteriology. All MG and MS tests, with the exception of MG ELISA kit D showed a lower percentage of positive samples during 35 d.p.i. for the detection of the MG and MS ATCC strain infection compared with that of the field strains. Also, the number of cross-reactions (false positives) in the serologic tests was lower after infection with an ATCC strain than after an infection with the MG or MS field strain. Contradictory to other studies, the ELISAs and the RPA test using undiluted serum showed a relatively high number of false-positive results. The MG ELISAs (except ELISA kit D) showed more false-positive results (up to 37%) in the MIM-infected group than in the MS-infected groups. This was not unexpected, as MIM and MG have a close antigenic relationship. The results of the serologic tests in this study showed that a certain level of false-positive results can be expected in about any serologic test. Although the level of false-positive results varied between several serologic tests, this study showed that it is not advisable to rely completely on one test (system) only.
Sherlock Holmes and child psychopathology assessment approaches: the case of the false-positive.
Jensen, P S; Watanabe, H
1999-02-01
To explore the relative value of various methods of assessing childhood psychopathology, the authors compared 4 groups of children: those who met criteria for one or more DSM diagnoses and scored high on parent symptom checklists, those who met psychopathology criteria on either one of these two assessment approaches alone, and those who met no psychopathology assessment criterion. Parents of 201 children completed the Child Behavior Checklist (CBCL), after which children and parents were administered the Diagnostic Interview Schedule for Children (version 2.1). Children and parents also completed other survey measures and symptom report inventories. The 4 groups of children were compared against "external validators" to examine the merits of "false-positive" and "false-negative" cases. True-positive cases (those that met DSM criteria and scored high on the CBCL) differed significantly from the true-negative cases on most external validators. "False-positive" and "false-negative" cases had intermediate levels of most risk factors and external validators. "False-positive" cases were not normal per se because they scored significantly above the true-negative group on a number of risk factors and external validators. A similar but less marked pattern was noted for "false-negatives." Findings call into question whether cases with high symptom checklist scores despite no formal diagnoses should be considered "false-positive." Pending the availability of robust markers for mental illness, researchers and clinicians must resist the tendency to reify diagnostic categories or to engage in arcane debates about the superiority of one assessment approach over another.
Miller, Kennon; Harrington, Susan M; Procop, Gary W
2015-08-01
New molecular diagnostic tests are attractive because of the potential they hold for improving diagnostics in microbiology. The value of these tests, which is often assumed, should be investigated to determine the best use of these potentially powerful tools. To investigate the usefulness of broad-range polymerase chain reaction (PCR), followed by sequencing, in mycobacterial infections. We reviewed the test performance of acid-fast bacilli (AFB) PCR and traditional diagnostic methods (histopathology, AFB smear, and culture). We assessed the diagnostic effect and cost of the unrestricted ordering of broad-range PCR for the detection and identification of mycobacteria in clinical specimens. The AFB PCR was less sensitive than culture and histopathology and was less specific than culture, AFB smear, and histopathology. During 18 months, $93 063 was spent on 183 patient specimens for broad-range PCR and DNA sequencing for mycobacteria to confirm one culture-proven Mycobacterium tuberculosis infection that was also known to be positive by AFB smear and histopathology. In this cohort, there was a false-negative AFB PCR for M tuberculosis and a false-positive AFB PCR for Mycobacterium lentiflavum . Testing of AFB smear-negative specimens from patients without an inflammatory response supportive of a mycobacterial infection is costly and has not been proven to improve patient care. Traditional diagnostics (histopathology, AFB smear, and culture) should remain the primary methods for the detection of mycobacteria in clinical specimens.
Rui, Y; Han, M; Zhou, W; He, Q; Li, H; Li, P; Zhang, F; Shi, Y; Su, X
2018-06-06
To determine true negatives and characterise the variables associated with false-negative results when interpreting non-malignant results of computed tomography (CT)-guided lung biopsy. Nine hundred and fifty patients with initial non-malignant findings on their first transthoracic CT-guided core-needle biopsy (TTNB) were included in the study. Initial biopsy results were compared to definitive diagnoses established later. The negative predictive value (NPV) of non-malignant diseases upon initial TTNB was 83.6%. When the biopsy results indicated specific infection or benign tumour (n=225, 26.1%), they all were confirmed true negative for malignancy later. Only one inconclusive "granuloma" diagnosis was false negative. All 141 patients (141/861, 16.4%) who were false negative for malignancy were from the "infection not otherwise specified (NOS)", "inflammatory diseases", or "inconclusive" groups. Age (p=0.002), cancer history (p<0.001), target size (p=0.003), and pneumothorax during lung biopsy (p=0.003) were found to be significant predictors of false-negative results; 47.6% (410/861) of patients underwent additional invasive examinations to reach a final diagnosis. Ultimately, 52.7% (216/410) were successfully diagnosed. Specific infection, benign tumour, and granulomatous inflammation of first TTNBs were mostly true negative. Older age, history of cancer, larger target size, and pneumothorax were highly predictive of false-negative results for malignancies. In such cases, additional invasive examinations were frequently necessary to obtain final diagnoses. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Yang, Chi; Zhang, Shaojun; Yao, Lan; Fan, Lin
2018-05-01
Objective To investigate the diagnostic efficacy of an interferon-γ release assay, T-SPOT ® . TB, for diagnosing active tuberculosis (TB) and to identify risk factors for false-negative results. Methods This retrospective study enrolled consecutive patients with active TB and with non-TB respiratory diseases to evaluate the risk factors for false-negative results when using the T-SPOT ® . TB assay for the diagnosis of active TB. Patients with active TB were categorized as having confirmed pulmonary TB, clinically diagnosed pulmonary TB or extrapulmonary TB (EPTB). Results This study analysed 4964 consecutive patients; 2425 with active TB and 2539 with non-TB respiratory diseases. Multivariate logistic regression analyses identified the following five factors that were all associated with an increased false-negative rate with the T-SPOT ® . TB assay: increased age (odds ratio [OR] 1.018; 95% confidence interval [CI] 1.013, 1.024); decreased CD8+ count (OR 0.307; 95% CI 0.117, 0.803); negative sputum acid-fast bacilli (AFB) smear staining (OR 1.821; 95% CI 1.338, 2.477); negative mycobacterial cultures (OR 1.379; 95% CI 1.043, 1.824); and absence of EPTB (OR 1.291; 95% CI 1.026, 1.623). Conclusions Increased age, decreased CD8+ count, negative sputum AFB smear results, negative sputum mycobacterial cultures and absence of EPTB might lead to an increased false-negative rate when using the T-SPOT ® . TB assay.
Where Have All the Interactions Gone? Estimating the Coverage of Two-Hybrid Protein Interaction Maps
Huang, Hailiang; Jedynak, Bruno M; Bader, Joel S
2007-01-01
Yeast two-hybrid screens are an important method for mapping pairwise physical interactions between proteins. The fraction of interactions detected in independent screens can be very small, and an outstanding challenge is to determine the reason for the low overlap. Low overlap can arise from either a high false-discovery rate (interaction sets have low overlap because each set is contaminated by a large number of stochastic false-positive interactions) or a high false-negative rate (interaction sets have low overlap because each misses many true interactions). We extend capture–recapture theory to provide the first unified model for false-positive and false-negative rates for two-hybrid screens. Analysis of yeast, worm, and fly data indicates that 25% to 45% of the reported interactions are likely false positives. Membrane proteins have higher false-discovery rates on average, and signal transduction proteins have lower rates. The overall false-negative rate ranges from 75% for worm to 90% for fly, which arises from a roughly 50% false-negative rate due to statistical undersampling and a 55% to 85% false-negative rate due to proteins that appear to be systematically lost from the assays. Finally, statistical model selection conclusively rejects the Erdös-Rényi network model in favor of the power law model for yeast and the truncated power law for worm and fly degree distributions. Much as genome sequencing coverage estimates were essential for planning the human genome sequencing project, the coverage estimates developed here will be valuable for guiding future proteomic screens. All software and datasets are available in Datasets S1 and S2, Figures S1–S5, and Tables S1−S6, and are also available from our Web site, http://www.baderzone.org. PMID:18039026
Otgaar, Henry; Howe, Mark L; Muris, Peter
2017-09-01
We examined the creation of spontaneous and suggestion-induced false memories in maltreated and non-maltreated children. Maltreated and non-maltreated children were involved in a Deese-Roediger-McDermott false memory paradigm where they studied and remembered negative and neutral word lists. Suggestion-induced false memories were created using a misinformation procedure during which both maltreated and non-maltreated children viewed a negative video (i.e., bank robbery) and later received suggestive misinformation concerning the event. Our results showed that maltreated children had higher levels of spontaneous negative false memories but lower levels of suggestion-induced false memories as compared to non-maltreated children. Collectively, our study demonstrates that maltreatment both increases and decreases susceptibility to memory illusions depending on the type of false memory being induced. Statement of contribution What is already known on this subject? Trauma affects memory. It is unclear how trauma affects false memory. What does this study add? This study focuses on two types of false memories. © 2017 The Authors. British Journal of Developmental Psychology published by John Wiley & Sons Ltd on behalf of British Psychological Society.
Feasibility of automated visual field examination in children between 5 and 8 years of age.
Safran, A. B.; Laffi, G. L.; Bullinger, A.; Viviani, P.; de Weisse, C.; Désangles, D.; Tschopp, C.; Mermoud, C.
1996-01-01
AIMS--To investigate how young children develop the ability to undergo a visual field evaluation using regular automated perimetry. METHODS--The study included 42 normal girls aged 5, 6, 7, and 8 years. Twelve locations in the 15 degrees eccentricity were tested in one eye, using an Octopus 2000R perimeter with a two level strategy. False positive and false negative catch trials were presented. The examination was performed three times in succession. Before the examination procedure, a specially designed programme was conducted for progressive familiarisation. RESULTS--During the familiarisation procedure, it was found that all of the 5-year-old children, seven of the 6-year-old children, and three of the 7-year-old children were unable to perform immediately, and correctly, the instructions given during the familiarisation phase; these children took from 30 seconds to 3 minutes to comply with the examiner's requests. With the exception of one 5-year-old child, all tested subjects completed the planned procedure. The mean proportion of false negative answers in catch trials was 1.6%. The mean proportion of false positive answers was 12.2%. The quadratic dependency on age suggested by the averages was not significant (F(3,116) = 0.88; p = 0.45). Detection stimulus improved with age, as shown by the fact that probability of perceiving dim stimulus increases significantly (F(3,116) = 12.68; p < 0.0001). CONCLUSION--Children did remarkably well regarding both the duration of the examination and the reliability of the answers. A preliminary familiarisation phase with a specially designed adaptation programme was found to be mandatory with children aged 7 or under. To our knowledge, this is the first time that such an investigation has been performed. PMID:8759261
Tiono, Alfred B; Ouédraogo, Alphonse; Diarra, Amidou; Coulibaly, Sam; Soulama, Issiaka; Konaté, Amadou T; Barry, Aïssata; Mukhopadhyay, Amitava; Sirima, Sodiomon B; Hamed, Kamal
2014-01-27
Rapid diagnostic tests (RDTs) are immune chromatographic tests targeting antigens of one or more Plasmodium species and offer the potential to extend accurate malaria diagnosis in endemic areas. In this study, the performance of Plasmodium falciparum-specific histidine-rich protein-2 (PfHRP-2) RDT in the detection of asymptomatic carriers from a hyperendemic region of Burkina Faso was compared with microscopy to gain further insight on its relevance in community-based interventions. The performance of HRP-2 test was evaluated in terms of sensitivity, specificity, positive and negative predictive values, discordant values, likelihood ratios, accuracy, and precision using microscopy as the 'gold standard'. This analysis was carried out in a controlled, parallel, cluster-randomized (18 clusters; 1:1) study in children and adults. The effect of systematic treatment of P. falciparum asymptomatic carriers during three consecutive monthly community screening campaigns on the incidence of symptomatic malaria episodes over a 12-month period was compared with no treatment of asymptomatic carriers. Sensitivity of HRP-2 test in asymptomatic carriers was higher in campaign 1 (92.4%) when compared to campaign 2 (84.0%) and campaign 3 (77.8%). The sensitivity of HRP-2 test increased as parasite density increased across all the age groups. Highest sensitivity (≥97.0%) was recorded at parasite densities of 1,000-4,999/μl, except for children aged 10 to 14 years. The specificity of HRP-2 test was comparable across age groups and highest in campaign 3 (95.9%). The negative predictive values were high across the three campaigns (≥92.7%) while the positive predictive values ranged from 23.2 to 73.8%. False-positive and false-negative rates were high in campaign 1 and campaign 3, respectively. The performance of HRP-2 test in detecting asymptomatic carriers of P. falciparum varied by age and parasite density. Although the use of HRP-2 test is beneficial for the diagnosis of acute malaria, its low sensitivity in screening asymptomatic carriers may limit its utility in pre-elimination interventional settings. The use of a practical and more sensitive test such as loop-mediated isothermal amplification in combination with a cost effective HRP-2 test may be worth exploring in such settings.
Petrillo, Antonella; Fusco, Roberta; Petrillo, Mario; Triunfo, Flavia; Filice, Salvatore; Vallone, Paolo; Setola, Sergio Venanzio; Rubulotta, Mariarosaria; Di Bonito, Maurizio; Rinaldo, Massimo; D'Aiuto, Massimiliano; Brunetti, Arturo
2017-06-01
The purpose of this study was to evaluate the added value of breast magnetic resonance imaging (MRI) in preoperative diagnosis of ductal carcinoma in situ (DCIS). We reviewed our institution database of 3499 consecutive patients treated for breast cancer. A total of 362 patients with histologically proven DCIS were selected from the institutional database. Of these, 245 (67.7%) preoperatively underwent conventional imaging (CI) (mammography/ultrasonography) (CI group), and 117 (32.3%) underwent CI and dynamic MRI (CI + MRI group). The pathology of surgical specimens served as a reference standard. The Mann-Whitney U, χ 2 test, and Spearman correlation coefficient were performed. The CI + MRI group showed a sensitivity of 98.5% with an increase of 10.1% compared with the CI group to detect pure DCIS. Dynamic MRI identified 19.7% (n = 13) additional pure DCIS compared with CI. In the CI + MRI group, a single (1.5%) false negative was reported, whereas in the CI group, 11 (11.6%) false negatives were reported. Moreover, the CI + MRI group showed a sensitivity of 98.0% to detect DCIS + small invasive component. In this group, dynamic MRI identified 21.6% (n = 11) additional DCIS and a single (2.0%) false negative compared with the CI group, whereas in the CI group, 7 (4.7%) false negatives were reported. MRI and histopathologically measured lesion sizes, Breast Imaging Reporting and Data System MRI assessment categories, and enhancement signal intensity curve types showed a significant correlation. The MRI detection rate of DCIS increased significantly with increasing nuclear grade. Preoperative breast MRI showed a better accuracy then CI in preoperative diagnosis for both pure DCIS and DCIS + small invasive component with a precise assessment of lesion size. This can provide a more appropriate management of DCIS patients. Copyright © 2016 Elsevier Inc. All rights reserved.
Jia, Tingting; Zhang, Lei; Wang, Guojing; Zhang, Rui; Zhang, Kuo; Lin, Guigao; Xie, Jiehong; Wang, Lunan; Li, Jinming
2015-01-01
In recent years, nucleic acid tests for detection of measles virus RNA have been widely applied in laboratories belonging to the measles surveillance system of China. An external quality assessment program was established by the National Center for Clinical Laboratories to evaluate the performance of nucleic acid tests for measles virus. The external quality assessment panel, which consisted of 10 specimens, was prepared using armored RNAs, complex of noninfectious MS2 bacteriophage coat proteins encapsulated RNA of measles virus, as measles virus surrogate controls. Conserved sequences amplified from a circulating measles virus strain or from a vaccine strain were encapsulated into these armored RNAs. Forty-one participating laboratories from 15 provinces, municipalities, or autonomous regions that currently conduct molecular detection of measles virus enrolled in the external quality assessment program, including 40 measles surveillance system laboratories and one diagnostic reagent manufacturer. Forty laboratories used commercial reverse transcription-quantitative PCR kits, with only one laboratory applying a conventional PCR method developed in-house. The results indicated that most of the participants (38/41, 92.7%) were able to accurately detect the panel with 100% sensitivity and 100% specificity. Although a wide range of commercially available kits for nucleic acid extraction and reverse transcription polymerase chain reaction were used by the participants, only two false-negative results and one false-positive result were generated; these were generated by three separate laboratories. Both false-negative results were obtained with tests performed on specimens with the lowest concentration (1.2 × 104 genomic equivalents/mL). In addition, all 18 participants from Beijing achieved 100% sensitivity and 100% specificity. Overall, we conclude that the majority of the laboratories evaluated have reliable diagnostic capacities for the detection of measles virus. PMID:26244795
Zhang, Dong; Sun, Yu; Jia, Tingting; Zhang, Lei; Wang, Guojing; Zhang, Rui; Zhang, Kuo; Lin, Guigao; Xie, Jiehong; Wang, Lunan; Li, Jinming
2015-01-01
In recent years, nucleic acid tests for detection of measles virus RNA have been widely applied in laboratories belonging to the measles surveillance system of China. An external quality assessment program was established by the National Center for Clinical Laboratories to evaluate the performance of nucleic acid tests for measles virus. The external quality assessment panel, which consisted of 10 specimens, was prepared using armored RNAs, complex of noninfectious MS2 bacteriophage coat proteins encapsulated RNA of measles virus, as measles virus surrogate controls. Conserved sequences amplified from a circulating measles virus strain or from a vaccine strain were encapsulated into these armored RNAs. Forty-one participating laboratories from 15 provinces, municipalities, or autonomous regions that currently conduct molecular detection of measles virus enrolled in the external quality assessment program, including 40 measles surveillance system laboratories and one diagnostic reagent manufacturer. Forty laboratories used commercial reverse transcription-quantitative PCR kits, with only one laboratory applying a conventional PCR method developed in-house. The results indicated that most of the participants (38/41, 92.7%) were able to accurately detect the panel with 100% sensitivity and 100% specificity. Although a wide range of commercially available kits for nucleic acid extraction and reverse transcription polymerase chain reaction were used by the participants, only two false-negative results and one false-positive result were generated; these were generated by three separate laboratories. Both false-negative results were obtained with tests performed on specimens with the lowest concentration (1.2 × 104 genomic equivalents/mL). In addition, all 18 participants from Beijing achieved 100% sensitivity and 100% specificity. Overall, we conclude that the majority of the laboratories evaluated have reliable diagnostic capacities for the detection of measles virus.
Kissinger, Patricia; White, Scott; Manhart, Lisa E.; Schwebke, Jane; Taylor, Stephanie N; Mena, Leandro; Khosropour, Christine M; Wilcox, Larissa; Schmidt, Norine; Martin, David H
2016-01-01
Background Three recent prospective studies have suggested that the 1 g dose of azithromycin for Chlamydia trachomatis (Ct) was less effective than expected, reporting a wide range of treatment failure rates (5.8%–22.6%). Reasons for the disparate results could be attributed to geographic or methodological differences. The purpose of this study was to re-examine the studies and attempt to harmonize methodologies to reduce misclassification as a result of false positives from early test-of-cure (TOC) or reinfection as a result of sexual exposure rather than treatment failure. Methods Men who had sex with women, who received 1 g azithromycin under directly observed therapy (DOT) for presumptive treatment of nongonococcal urethritis (NGU) with confirmed Ct were included. Baseline screening was performed on urethral swabs or urine and TOC screening was performed on urine using nucleic acid amplification tests (NAAT). Post-treatment vaginal sexual exposure was elicited at TOC. Data from the three studies was obtained and re-analyzed. Rates of Ct re-test positive were examined for all cases and a sensitivity analysis was conducted to either reclassify potential false positives/reinfections as negative or remove them from the analysis. Results The crude treatment failure rate was 12.8% (31/242). The rate when potential false positives/reinfections were reclassified as negative was 6.2% (15/242) or when these were excluded from analysis was 10.9% (15/138). Conclusion In these samples of men who have sex with women with Ct-related NGU, azithromycin treatment failure was between 6.2% and 12.8%. This range of failure is lower than previously published but higher than the desired World Health Organization’s target chlamydia treatment failure rate of < 5%. PMID:27631353
Gotfred-Rasmussen, Helle; Lund, Marianne; Enemark, Heidi L; Erlandsen, Mogens; Petersen, Eskild
2016-03-01
For decades, microscopy of feces after formol-ethylacetate (FEA) concentration and iodine staining has been the routine test for intestinal protozoa. Lately, polymerase chain reaction or fluorescence-labeled parasite-specific antibodies have been introduced, but their place in everyday routine diagnostics has not yet been established. We compared FEA and salt-sugar flotation (SSF) concentration followed by microscopy of iodine-stained concentrate and immunofluorescence assay (IFA) and real-time polymerase chain reaction (qPCR) for detection of Giardia duodenalis in human feces. The median number of Giardia cysts found by FEA in 19 Giardia-positive samples was 50 cysts per gram (CPG), by SSF 350 CPG, by IFA 76,700 CPG, and by qPCR 316,000 CPG. We next tested 455 consecutive samples for presence of Giardia cysts. Using IFA as reference, qPCR had a sensitivity of 91%, specificity of 95.1%, a false-positive rate of 50%, a false-negative rate of 0.48%, a positive predictive value of 50%, and a negative predictive value of 99.5%. In conclusion, qPCR and IFA were significantly more sensitive than microscopy of iodine-stained concentrates using either FEA or SSF. We suggest, when using qPCR, that positive samples are verified by IFA to prevent false-positive results. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Grati, Francesca R; Malvestiti, Francesca; Grimi, Beatrice; Gaetani, Elisa; Di Meco, Anna Maria; Trotta, Anna; Liuti, Rosaria; Chinetti, Sara; Dulcetti, Francesca; Ruggeri, Anna Maria; Agrati, Cristina; Frascoli, Giuditta; Milani, Silvia; De Toffol, Simona; Martinoni, Lorenza; Paganini, Silvia; Marcato, Livia; Maggi, Federico; Simoni, Giuseppe
2013-05-01
Karyotyping on chorionic villous samples (CVS) includes the analysis of both cytotrophoblast (STC) and mesenchyme (LTC). This approach requires complex laboratory organization and trained technicians. The introduction of quantitative fluorescent polymerase chain reaction (QF-PCR) instead of conventional karyotyping in low-risk pregnancies opened its application in CVS analysis. Discordant QF-PCR and CVS cytogenetic results were reported, and strategies for CVS analysis were introduced to minimize this risk. The possibility to substitute the STC with QF-PCR was reported. The aim of this study is to evaluate benefits and limitations of the approach QF-PCR + LTC compared with the traditional method STC + LTC and to quantify the associated risks of false results. This study is based on a retrospective cytogenetic audit of CVS results (n = 44 727) generated by the STC + LTC analytic approach. False-negative risks related to true fetal mosaicism type IV, imprinting syndromes and maternal contamination in LTC were calculated. Compared with STC + LTC, QF-PCR + LTC approach is associated with a cumulative false-negative risk of ~1/3100-1/4400. Costs and reporting time of STC in a high-throughput cytogenetic lab are similar to a CE-IVD marked QF-PCR analysis. These results should be clearly highlighted in the pre-test counseling and extensively discussed with the couple prior to testing for informed consent. © 2013 John Wiley & Sons, Ltd.
The influence of filtering and downsampling on the estimation of transfer entropy
Florin, Esther; von Papen, Michael; Timmermann, Lars
2017-01-01
Transfer entropy (TE) provides a generalized and model-free framework to study Wiener-Granger causality between brain regions. Because of its nonparametric character, TE can infer directed information flow also from nonlinear systems. Despite its increasing number of applications in neuroscience, not much is known regarding the influence of common electrophysiological preprocessing on its estimation. We test the influence of filtering and downsampling on a recently proposed nearest neighborhood based TE estimator. Different filter settings and downsampling factors were tested in a simulation framework using a model with a linear coupling function and two nonlinear models with sigmoid and logistic coupling functions. For nonlinear coupling and progressively lower low-pass filter cut-off frequencies up to 72% false negative direct connections and up to 26% false positive connections were identified. In contrast, for the linear model, a monotonic increase was only observed for missed indirect connections (up to 86%). High-pass filtering (1 Hz, 2 Hz) had no impact on TE estimation. After low-pass filtering interaction delays were significantly underestimated. Downsampling the data by a factor greater than the assumed interaction delay erased most of the transmitted information and thus led to a very high percentage (67–100%) of false negative direct connections. Low-pass filtering increases the number of missed connections depending on the filters cut-off frequency. Downsampling should only be done if the sampling factor is smaller than the smallest assumed interaction delay of the analyzed network. PMID:29149201
Gartiser, Stefan; Hafner, Christoph; Kronenberger-Schäfer, Kerstin; Happel, Oliver; Trautwein, Christoph; Kümmerer, Klaus
2012-09-01
Many pharmaceuticals and related metabolites are not efficiently removed in sewage treatment plants and enter into surface water. There, they might be subject of drinking water abstraction and treatment by ozonation. In this study, a systematic approach for producing and effect-based testing of transformation products (TPs) during the drinking water ozonation process is proposed. For this, two pharmaceutical parent substances, three metabolites and one environmental degradation product were investigated with respect to their biodegradability and fate during drinking water ozonation. The Ames test (TA98, TA100) was used for the identification of mutagenic activity present in the solutions after testing inherent biodegradability and/or after ozonation of the samples. Suspicious results were complemented with the umu test. Due to the low substrate concentration required for ozonation, all ozonated samples were concentrated via solid phase extraction (SPE) before performing the Ames test. With the exception of piracetam, all substances were only incompletely biodegradable, suggesting the formation of stable TPs. Metformin, piracetam and guanylurea could not be removed completely by the ozonation process. We received some evidence that technical TPs are formed by ozonation of metformin and piracetam, whereas all tested metabolites were not detectable by analytical means after ozonation. In the case of guanylurea, one ozonation TP was identified by LC/MS. None of the experiments showed an increase of mutagenic effects in the Ames test. However, the SPE concentration procedure might lead to false-positive results due to the generation of mutagenic artefacts or might lead to false-negative results by missing adequate recovery efficiency. Thus, these investigations should always be accompanied by process blank controls that are carried out along the whole ozonation and SPE procedure. The study presented here is a first attempt to investigate the significance of transformation products by a systematic approach. However, the adequacy and sensitivity of the methodology need to be further investigated. The approach of combining biodegradation and ozonation with effect-based assays is a promising tool for the early detection of potential hazards from TPs as drinking water contaminants. It can support the strategy for the evaluation of substances and metabolites in drinking water. A multitude of possible factors which influence the results have to be carefully considered, among them the selectivity and sensibility of the mutagenicity test applied, the extraction method for concentrating the relevant compounds and the biocompatibility of the solvent. Therefore, the results have to be carefully interpreted, and possible false-negative and false-positive results should be considered.
There was not, they did not: May negation cause the negated ideas to be remembered as existing?
2017-01-01
In this article we demonstrate that negation of ideas can have paradoxical effects, possibly leading the listener to believe that the negated ideas actually existed. In Experiment 1, participants listened to a description of a house, in which some objects were mentioned, some were negated, and some were not mentioned at all. When questioned about the existence of these objects a week later, the participants gave more false positives for items that were negated in the original material than for items that were not mentioned at all, an effect we call negation related false memories (NRFM). The NRFM effect was replicated again in Experiment 2 with a sample of five and six year-old children. Experiment 3 confirmed NRFM in the case of negated actions. The results are discussed in terms of retention hypothesis, as well as the theory that negation can activate a representation of an entity and behaviour. It is also indicated that future research is needed to ensure that it is indeed negation which caused false alarms, not merely mentioning an object. PMID:28448549
Iqbal, H. Syed; Solomon, Suniti; Murugavel, K. G.; Solomon, Sunil Suhas; Balakrishnan, P.
2005-01-01
Diagnosis of human immunodeficiency virus (HIV) infection is important for patient management and prevention of new infections. The number of test kits available for the detection of HIV antibodies is unprecedented. In order to identify appropriate test kits, we evaluated a variety of commercial kits manufactured abroad as well as in India. The plasma and serum specimens (n = 264) were collected from individuals attending the Voluntary Counseling and Testing Centre at the YRG Centre for AIDS and Education. The specimens were used to evaluate six commercially available HIV test kits: Enzaids HIV 1+2, HIV-CheX, Murex HIV-1.2.0, Genscreen HIV 1/2 version 2, Vironostika HIV Uni-Form II Ag/Ab, and CombAids RS Advantage. High sensitivities and specificities (≥99%) were observed for the Enzaids, Murex, Vironostika, and CombAids assays. HIV-CheX showed the highest number of false-positive and false-negative results. The Genscreen test also gave many false positives. The study indicated that the Enzaids, Murex, and Vironostika enzyme-linked immunosorbent assay kits and the CombAids RS Advantage rapid assay could be used to achieve acceptable results for the detection of HIV antibodies. A combination of two tests is recommended to optimize the efficiency of HIV antibody testing algorithms, especially when evaluation with an HIV Western blot confirmatory test is not possible. PMID:16339066
Generalized site occupancy models allowing for false positive and false negative errors
Royle, J. Andrew; Link, W.A.
2006-01-01
Site occupancy models have been developed that allow for imperfect species detection or ?false negative? observations. Such models have become widely adopted in surveys of many taxa. The most fundamental assumption underlying these models is that ?false positive? errors are not possible. That is, one cannot detect a species where it does not occur. However, such errors are possible in many sampling situations for a number of reasons, and even low false positive error rates can induce extreme bias in estimates of site occupancy when they are not accounted for. In this paper, we develop a model for site occupancy that allows for both false negative and false positive error rates. This model can be represented as a two-component finite mixture model and can be easily fitted using freely available software. We provide an analysis of avian survey data using the proposed model and present results of a brief simulation study evaluating the performance of the maximum-likelihood estimator and the naive estimator in the presence of false positive errors.
van de Groep, Kirsten; Bos, Martine P; Savelkoul, Paul H M; Rubenjan, Anna; Gazenbeek, Christel; Melchers, Willem J G; van der Poll, Tom; Juffermans, Nicole P; Ong, David S Y; Bonten, Marc J M; Cremer, Olaf L
2018-04-26
Molecular tests may enable early adjustment of antimicrobial therapy and be complementary to blood culture (BC) which has imperfect sensitivity in critically ill patients. We evaluated a novel multiplex real-time PCR assay to diagnose bloodstream pathogens directly in whole blood samples (BSI-PCR). BSI-PCR included 11 species- and four genus-specific PCRs, a molecular Gram-stain PCR, and two antibiotic resistance markers. We collected 5 mL blood from critically ill patients simultaneously with clinically indicated BC. Microbial DNA was isolated using the Polaris method followed by automated DNA extraction. Sensitivity and specificity were calculated using BC as reference. BSI-PCR was evaluated in 347 BC-positive samples (representing up to 50 instances of each pathogen covered by the test) and 200 BC-negative samples. Bacterial species-specific PCR sensitivities ranged from 65 to 100%. Sensitivity was 26% for the Gram-positive PCR, 32% for the Gram-negative PCR, and ranged 0 to 7% for yeast PCRs. Yeast detection was improved to 40% in a smaller set-up. There was no overall association between BSI-PCR sensitivity and time-to-positivity of BC (which was highly variable), yet Ct-values were lower for true-positive versus false-positive PCR results. False-positive results were observed in 84 (4%) of the 2200 species-specific PCRs in 200 culture-negative samples, and ranged from 0 to 6% for generic PCRs. Sensitivity of BSI-PCR was promising for individual bacterial pathogens, but still insufficient for yeasts and generic PCRs. Further development of BSI-PCR will focus on improving sensitivity by increasing input volumes and on subsequent implementation as a bedside test.
Value of a Single-Tube Widal Test in Diagnosis of Typhoid Fever in Vietnam
Parry, Christopher M.; Hoa, Nguyen Thi Tuyet; Diep, To Song; Wain, John; Chinh, Nguyen Tran; Vinh, Ha; Hien, Tran Tinh; White, Nicholas J.; Farrar, Jeremy J.
1999-01-01
The diagnostic value of an acute-phase single-tube Widal test for suspected typhoid fever was evaluated with 2,000 Vietnamese patients admitted to an infectious disease referral hospital between 1993 and 1998. Test patients had suspected typhoid fever and a blood culture positive for Salmonella typhi (n= 1,400) or Salmonella paratyphi A (n = 45). Control patients had a febrile illness for which another cause was confirmed (malaria [n = 103], dengue [n = 76], or bacteremia due to another microorganism [n = 156] or tetanus (n = 265). An O-agglutinin titer of ≥100 was found in 18% of the febrile controls and 7% of the tetanus patients. Corresponding values for H agglutinins were 8 and 1%, respectively. The O-agglutinin titer was ≥100 in 83% of the blood culture-positive typhoid fever cases, and the H-agglutinin titer was ≥100 in 67%. The disease prevalence in investigated patients in this hospital was 30.8% (95% confidence interval, 26.8 to 35.1%); at this prevalence, an elevated level of H agglutinins gave better positive predictive values for typhoid fever than did O agglutinins. With a cutoff titer of ≥200 for O agglutinin or ≥100 for H agglutinin, the Widal test would diagnose correctly 74% of the blood culture-positive cases of typhoid fever. However, 14% of the positive results would be false-positive, and 10% of the negative results would be false-negative. The Widal test can be helpful in the laboratory diagnosis of typhoid fever in Vietnam if interpreted with care. PMID:10449469
Bamber, A I; Fitzsimmons, K; Cunniffe, J G; Beasor, C C; Mackintosh, C A; Hobbs, G
2012-01-01
The laboratory diagnosis of Clostridium difficile infection (CDI) needs to be accurate and timely to ensure optimal patient management, infection control and reliable surveillance. Three methods are evaluated using 810 consecutive stool samples against toxigenic culture: CDT TOX A/B Premier enzyme immunoassay (EIA) kit (Meridian Bioscience, Europe), Premier EIA for C. difficile glutamate dehydrogenase (GDH) (Meridian Bioscience, Europe) and the Illumigene kit (Meridian Bioscience, Europe), both individually and within combined testing algorithms. The study revealed that the CDT TOX A/B Premier EIA gave rise to false-positive and false-negative results and demonstrated poor sensitivity (56.47%), compared to Premier EIA for C. difficile GDH (97.65%), suggesting this GDH EIA can be a useful negative screening method. Results for the Illumigene assay alone showed sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) of 91.57%, 98.07%, 99.03% and 84.44%, respectively. A two-stage algorithm using Premier EIA for C. difficile GDH/Illumigene assay yielded superior results compared with other testing algorithms (91.57%, 98.07%, 99.03% and 84.44%, respectively), mirroring the Illumigene performance. However, Illumigene is approximately half the cost of current polymerase chain reaction (PCR) methods, has a rapid turnaround time and requires no specialised skill base, making it an attractive alternative to assays such as the Xpert C. difficile assay (Cepheid, Sunnyvale, CA). A three-stage algorithm offered no improvement and would hamper workflow.
Kamugisha, M L; Msangeni, H; Beale, E; Malecela, E K; Akida, J; Ishengoma, D R S; Lemnge, M M
2008-01-01
Malaria is a major public health problem particularly in rural Sub-Saharan Africa. In most urban areas, malaria transmission intensity is low thus monitoring trends using reliable tools is crucial to provide vital information for future management of the disease. Rapid diagnostic tests (RDT) such as Paracheck Pf are now increasingly adopted for Plasmodium falciparum malaria diagnosis and are advantageous and cost effective alternative to microscopy. This cross sectional survey was carried out during June 2005 to determine the prevalence of malaria in an urban setting and compare microscopy diagnosis versus Paracheck Pf for detecting Plasmodium falciparum. Blood samples from a total of 301 children (< 10 years) attending outpatient clinic at Makorora Health Centre, in Tanga, Tanzania were examined for the presence of malaria. Twenty-nine (9.6%) of the children were positive to malaria by microscopy while 30 (10.0%) were positive by Paracheck test. Three out of 30 positive cases detected by Paracheck were negative by microscopy; thus considered to be false positive results. For the 271 Paracheck Pf negative cases, 2 were positive by microscopy; yielding 2 false negative results. Paracheck Pf sensitivity and specificity were 93.1% and 98.9%, respectively. P. falciparum was the only malarial species observed among the 29 microscopy positive cases. The prevalence of anaemia among the children was 53.16%. These findings indicate a low prevalence of malaria in Tanga City and that Paracheck Pf can be an effective tool for malaria diagnosis.
SAS molecular tests Salmonella detection kit. Performance tested method 021202.
Bapanpally, Chandra; Montier, Laura; Khan, Shah; Kasra, Akif; Brunelle, Sharon L
2014-01-01
The SAS Molecular tests Salmonella Detection method, a Loop-mediated Isothermal Amplification method, performed as well as or better than the U.S. Department of Agriculture-Food Safety Inspection Service Microbiology Laboratory Guidebook and the U.S. Food and Drug Administration Bacteriological Analytical Manual reference methods for ground beef, beef trim, ground turkey, chicken carcass rinses, bagged mixed lettuce, and fresh spinach. The ground beef (30% fat, 25 g test portion), poultry matrixes and leafy greens were validated in a 6-7 h enrichment, and ground beef (30% fat, 375 g composite test portion) and beef trim (375 g composite test portion) were validated in a 16-20 h enrichment. The method performance for meat and leafy green matrixes was shown to be acceptable under conditions of co-enrichment with Escherichia coli 0157. Thus, after a short 6-7 h co-enrichment step, ground beef, beef trim, lettuce, and spinach can be tested for both Salmonella and E. coli O157. Inclusivity and exclusivity testing revealed no false negatives and no false positives among the 100 Salmonella serovars and 30 non-Salmonella species examined. The method was shown to be robust when enrichment time, DNA extract hold time, and DNA volume were varied.
Tamkus, Arvydas A; Rice, Kent S; McCaffrey, Michael T
2018-02-01
Although some authors have published case reports describing false negatives in intraoperative neurophysiological monitoring (IONM), a systematic review of causes of false-negative IONM results is lacking. The objective of this study was to analyze false-negative IONM findings in spine surgery. This is a retrospective cohort analysis. A cohort of 109 patients with new postoperative neurologic deficits was analyzed for possible false-negative IONM reporting. The causes of false-negative IONM reporting were determined. From a cohort of 62,038 monitored spine surgeries, 109 consecutive patients with new postoperative neurologic deficits were reviewed for IONM alarms. Intraoperative neurophysiological monitoring alarms occurred in 87 of 109 surgeries. Nineteen patients with new postoperative neurologic deficits did not have an IONM alarm and surgeons were not warned. In addition, three patients had no interpretable IONM baseline data and no alarms were possible for the duration of the surgery. Therefore, 22 patients were included in the study. The absence of IONM alarms during these 22 surgeries had different origins: "true" false negatives where no waveform changes meeting the alarm criteria occurred despite the appropriate IONM (7); a postoperative development of a deficit (6); failure to monitor the pathway, which became injured (5); the absence of interpretable IONM baseline data which precluded any alarm (3); and technical IONM application issues (1). Overall, the rate of IONM method failing to predict the patient's outcome was very low (0.04%, 22/62,038). Minimizing false negatives requires the application of a proper IONM technique with the limitations of each modality considered in their selection and interpretation. Multimodality IONM provides the most inclusive information, and although it might be impractical to monitor every neural structure that can be at risk, a thorough preoperative consideration of available IONM modalities is important. Delayed development of postoperative deficits cannot be predicted by IONM. Absent baseline IONM data should be treated as an alarm when inconsistent with the patient's preoperative neurologic status. Alarm criteria for IONM may need to be refined for specific procedures and deserves continued study. Copyright © 2017 Elsevier Inc. All rights reserved.
Ginocchio, C. C.; Barth, D.; Zhang, F.
2008-01-01
This study compared the clinical performance of the Digene Hybrid Capture 2 (HC2) assay to that of a prototype Third Wave Invader human papillomavirus (HPV) (IHPV) analyte-specific reagent-based assay for the detection of oncogenic or “high-risk” (HR) HPV DNA using liquid-based cytology specimens. In total, 821 ThinPrep vials were tested using both assays. In accordance with the type-specific probes contained within each test, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the IHPV assay were 95.9%, 97.6%, 97.5%, and 96.1%, respectively, and those for the HC2 assay were 98.1%, 86.2%, 87.1%, and 97.9%. Overall, the sensitivity and NPV were comparable between the assays, but the IHPV assay demonstrated a better specificity and PPV, since the IHPV assay had fewer false-positive HR HPV results. The incorporation of an internal control to evaluate the cellularity of the test material is an important feature of the IHPV assay and should reduce the risk of false-negative results due to insufficient sample collection rather than the lack of HR HPV DNA. An additional benefit of the IHPV assay was the smaller sample volume required (1 ml versus 4 ml for the HC2 assay). PMID:18367578
Protein p16 as a marker of dysplastic and neoplastic alterations in cervical epithelial cells
Volgareva, Galina; Zavalishina, Larisa; Andreeva, Yulia; Frank, Georgy; Krutikova, Ella; Golovina, Darya; Bliev, Alexander; Spitkovsky, Dimitry; Ermilova, Valeriya; Kisseljov, Fjodor
2004-01-01
Background Cervical carcinomas are second most frequent type of women cancer. Success in diagnostics of this disease is due to the use of Pap-test (cytological smear analysis). However Pap-test gives significant portion of both false-positive and false-negative conclusions. Amendments of the diagnostic procedure are desirable. Aetiological role of papillomaviruses in cervical cancer is established while the role of cellular gene alterations in the course of tumor progression is less clear. Several research groups including us have recently named the protein p16INK4a as a possible diagnostic marker of cervical cancer. To evaluate whether the specificity of p16INK4a expression in dysplastic and neoplastic cervical epithelium is sufficient for such application we undertook a broader immunochistochemical registration of this protein with a highly p16INK4a-specific monoclonal antibody. Methods Paraffin-embedded samples of diagnostic biopsies and surgical materials were used. Control group included vaginal smears of healthy women and biopsy samples from patients with cervical ectopia. We examined 197 samples in total. Monoclonal antibody E6H4 (MTM Laboratories, Germany) was used. Results In control samples we did not find any p16INK4a-positive cells. Overexpression of p16INK4a was detected in samples of cervical dysplasia (CINs) and carcinomas. The portion of p16INK4a-positive samples increased in the row: CIN I – CIN II – CIN III – invasive carcinoma. For all stages the samples were found to be heterogeneous with respect to p16INK4a-expression. Every third of CINs III and one invasive squamous cell carcinoma (out of 21 analyzed) were negative. Conclusions Overexpression of the protein p16INK4a is typical for dysplastic and neoplastic epithelium of cervix uteri. However p16INK4a-negative CINs and carcinomas do exist. All stages of CINs and carcinomas analyzed are heterogeneous with respect to p16INK4a expression. So p16INK4a-negativity is not a sufficient reason to exclude a patient from the high risk group. As far as normal cervical epithelium is p16INK4a-negative and the ratio p16INK4a-positive/ p16INK4a-negative samples increases at the advanced stages application of immunohisto-/cytochemical test for p16INK4a may be regarded as a supplementary test for early diagnostics of cervical cancer. PMID:15339339
Yeo, Zhen Xuan; Wong, Joshua Chee Leong; Rozen, Steven G; Lee, Ann Siew Gek
2014-06-24
The Ion Torrent PGM is a popular benchtop sequencer that shows promise in replacing conventional Sanger sequencing as the gold standard for mutation detection. Despite the PGM's reported high accuracy in calling single nucleotide variations, it tends to generate many false positive calls in detecting insertions and deletions (indels), which may hinder its utility for clinical genetic testing. Recently, the proprietary analytical workflow for the Ion Torrent sequencer, Torrent Suite (TS), underwent a series of upgrades. We evaluated three major upgrades of TS by calling indels in the BRCA1 and BRCA2 genes. Our analysis revealed that false negative indels could be generated by TS under both default calling parameters and parameters adjusted for maximum sensitivity. However, indel calling with the same data using the open source variant callers, GATK and SAMtools showed that false negatives could be minimised with the use of appropriate bioinformatics analysis. Furthermore, we identified two variant calling measures, Quality-by-Depth (QD) and VARiation of the Width of gaps and inserts (VARW), which substantially reduced false positive indels, including non-homopolymer associated errors without compromising sensitivity. In our best case scenario that involved the TMAP aligner and SAMtools, we achieved 100% sensitivity, 99.99% specificity and 29% False Discovery Rate (FDR) in indel calling from all 23 samples, which is a good performance for mutation screening using PGM. New versions of TS, BWA and GATK have shown improvements in indel calling sensitivity and specificity over their older counterpart. However, the variant caller of TS exhibits a lower sensitivity than GATK and SAMtools. Our findings demonstrate that although indel calling from PGM sequences may appear to be noisy at first glance, proper computational indel calling analysis is able to maximize both the sensitivity and specificity at the single base level, paving the way for the usage of this technology for future clinical genetic testing.
Sadder and less accurate? False memory for negative material in depression.
Joormann, Jutta; Teachman, Bethany A; Gotlib, Ian H
2009-05-01
Previous research has demonstrated that induced sad mood is associated with increased accuracy of recall in certain memory tasks; the effects of clinical depression, however, are likely to be quite different. The authors used the Deese-Roediger-McDermott paradigm to examine the impact of clinical depression on erroneous recall of neutral and/or emotional stimuli. Specifically, they presented Deese-Roediger-McDermott lists that were highly associated with negative, neutral, or positive lures and compared participants diagnosed with major depressive disorder and nondepressed control participants on the accuracy of their recall of presented material and their false recall of never-presented lures. Compared with control participants, major depressive disorder participants recalled fewer words that had been previously presented but were more likely to falsely recall negative lures; there were no differences between major depressive disorder and control participants in false recall of positive or neutral lures. These findings indicate that depression is associated with false memories of negative material.
Rahal, M; Kervaire, B; Villard, J; Tiercy, J-M
2008-03-01
Human leukocyte antigen (HLA) typing by polymerase chain reaction-sequence-specific oligonucleotide (PCR-SSO) hybridization on solid phase (microbead assay) or polymerase chain reaction-sequence-specific primers (PCR-SSP) requires interpretation softwares to detect all possible allele combinations. These programs propose allele calls by taking into account false-positive or false-negative signal(s). The laboratory has the option to validate typing results in the presence of strongly cross-reacting or apparent false-negative signals. Alternatively, these seemingly aberrant signals may disclose novel variants. We report here four new HLA-B (B*5620 and B*5716) and HLA-DRB1 alleles (DRB1*110107 and DRB1*1474) that were detected by apparent false-negative or -positive hybridization or amplification patterns, and ultimately resolved by sequencing. To avoid allele misassignments, a comprehensive evaluation of acquired data as documented in a quality assurance system is therefore required to confirm unambiguous typing interpretation.
Imperfect pathogen detection from non-invasive skin swabs biases disease inference
DiRenzo, Graziella V.; Grant, Evan H. Campbell; Longo, Ana; Che-Castaldo, Christian; Zamudio, Kelly R.; Lips, Karen
2018-01-01
1. Conservation managers rely on accurate estimates of disease parameters, such as pathogen prevalence and infection intensity, to assess disease status of a host population. However, these disease metrics may be biased if low-level infection intensities are missed by sampling methods or laboratory diagnostic tests. These false negatives underestimate pathogen prevalence and overestimate mean infection intensity of infected individuals. 2. Our objectives were two-fold. First, we quantified false negative error rates of Batrachochytrium dendrobatidis on non-invasive skin swabs collected from an amphibian community in El Copé, Panama. We swabbed amphibians twice in sequence, and we used a recently developed hierarchical Bayesian estimator to assess disease status of the population. Second, we developed a novel hierarchical Bayesian model to simultaneously account for imperfect pathogen detection from field sampling and laboratory diagnostic testing. We evaluated the performance of the model using simulations and varying sampling design to quantify the magnitude of bias in estimates of pathogen prevalence and infection intensity. 3. We show that Bd detection probability from skin swabs was related to host infection intensity, where Bd infections < 10 zoospores have < 95% probability of being detected. If imperfect Bd detection was not considered, then Bd prevalence was underestimated by as much as 16%. In the Bd-amphibian system, this indicates a need to correct for imperfect pathogen detection caused by skin swabs in persisting host communities with low-level infections. More generally, our results have implications for study designs in other disease systems, particularly those with similar objectives, biology, and sampling decisions. 4. Uncertainty in pathogen detection is an inherent property of most sampling protocols and diagnostic tests, where the magnitude of bias depends on the study system, type of infection, and false negative error rates. Given that it may be difficult to know this information in advance, we advocate that the most cautious approach is to assume all errors are possible and to accommodate them by adjusting sampling designs. The modeling framework presented here improves the accuracy in estimating pathogen prevalence and infection intensity.
2014-01-01
Introduction Interval cancers are tumors arising after a negative screening episode and before the next screening invitation. They can be classified into true interval cancers, false-negatives, minimal-sign cancers, and occult tumors based on mammographic findings in screening and diagnostic mammograms. This study aimed to describe tumor-related characteristics and the association of breast density and tumor phenotype within four interval cancer categories. Methods We included 2,245 invasive tumors (1,297 screening-detected and 948 interval cancers) diagnosed from 2000 to 2009 among 645,764 women aged 45 to 69 who underwent biennial screening in Spain. Interval cancers were classified by a semi-informed retrospective review into true interval cancers (n = 455), false-negatives (n = 224), minimal-sign (n = 166), and occult tumors (n = 103). Breast density was evaluated using Boyd’s scale and was conflated into: <25%; 25 to 50%; 50 to 75%; >75%. Tumor-related information was obtained from cancer registries and clinical records. Tumor phenotype was defined as follows: luminal A: ER+/HER2- or PR+/HER2-; luminal B: ER+/HER2+ or PR+/HER2+; HER2: ER-/PR-/HER2+; triple-negative: ER-/PR-/HER2-. The association of tumor phenotype and breast density was assessed using a multinomial logistic regression model. Adjusted odds ratios (OR) and 95% confidence intervals (95% CI) were calculated. All statistical tests were two-sided. Results Forty-eight percent of interval cancers were true interval cancers and 23.6% false-negatives. True interval cancers were associated with HER2 and triple-negative phenotypes (OR = 1.91 (95% CI:1.22-2.96), OR = 2.07 (95% CI:1.42-3.01), respectively) and extremely dense breasts (>75%) (OR = 1.67 (95% CI:1.08-2.56)). However, among true interval cancers a higher proportion of triple-negative tumors was observed in predominantly fatty breasts (<25%) than in denser breasts (28.7%, 21.4%, 11.3% and 14.3%, respectively; <0.001). False-negatives and occult tumors had similar phenotypic characteristics to screening-detected cancers, extreme breast density being strongly associated with occult tumors (OR = 6.23 (95% CI:2.65-14.66)). Minimal-sign cancers were biologically close to true interval cancers but showed no association with breast density. Conclusions Our findings revealed that both the distribution of tumor phenotype and breast density play specific and independent roles in each category of interval cancer. Further research is needed to understand the biological basis of the overrepresentation of triple-negative phenotype among predominantly fatty breasts in true interval cancers. PMID:24410848
Classification of baseline toxicants for QSAR predictions to replace fish acute toxicity studies.
Nendza, Monika; Müller, Martin; Wenzel, Andrea
2017-03-22
Fish acute toxicity studies are required for environmental hazard and risk assessment of chemicals by national and international legislations such as REACH, the regulations of plant protection products and biocidal products, or the GHS (globally harmonised system) for classification and labelling of chemicals. Alternative methods like QSARs (quantitative structure-activity relationships) can replace many ecotoxicity tests. However, complete substitution of in vivo animal tests by in silico methods may not be realistic. For the so-called baseline toxicants, it is possible to predict the fish acute toxicity with sufficient accuracy from log K ow and, hence, valid QSARs can replace in vivo testing. In contrast, excess toxicants and chemicals not reliably classified as baseline toxicants require further in silico, in vitro or in vivo assessments. Thus, the critical task is to discriminate between baseline and excess toxicants. For fish acute toxicity, we derived a scheme based on structural alerts and physicochemical property thresholds to classify chemicals as either baseline toxicants (=predictable by QSARs) or as potential excess toxicants (=not predictable by baseline QSARs). The step-wise approach identifies baseline toxicants (true negatives) in a precautionary way to avoid false negative predictions. Therefore, a certain fraction of false positives can be tolerated, i.e. baseline toxicants without specific effects that may be tested instead of predicted. Application of the classification scheme to a new heterogeneous dataset for diverse fish species results in 40% baseline toxicants, 24% excess toxicants and 36% compounds not classified. Thus, we can conclude that replacing about half of the fish acute toxicity tests by QSAR predictions is realistic to be achieved in the short-term. The long-term goals are classification criteria also for further groups of toxicants and to replace as many in vivo fish acute toxicity tests as possible with valid QSAR predictions.
Mata, Luis; Sanz, David; Razquin, Pedro
2014-01-01
The Explorer(®) 2.0 tube test is a microbial inhibition test for the screening of antimicrobial residues in food samples. The new e-Reader(®) device coupled to Explorer(®) 2.0 operates by incubation at a selected temperature, determination of the endpoint of the assay and interpretation to generate results. This system was validated for muscle samples according to the European Commission Decision 2002/657/EC. Sensitivity towards 25 substances from several groups of antimicrobials was investigated in a first step. Detection capabilities for six substances representing the six major antimicrobial groups were also determined in bovine muscle. The detection capabilities for amoxicillin (10 µg l(-1)), cefalexin (200 µg l(-1)), doxycyclin (100 µg l(-1)), sulfamethazine (100 µg l(-1)), tylosin (100 µg l(-1)) and neomycin (200 µg l(-1)) were in all cases at or below the maximum residue limit (MRL). Specificity and applicability of the test were demonstrated with muscle samples from four animal species (bovine, porcine, ovine and poultry) and results were found to be satisfactory. Ruggedness was evaluated on negative and spiked samples with sulfamethazine as a representative antimicrobial. Neither false-positives nor false-negatives were detected when varying the sample volume, the time of pre-incubation, the temperature of incubation and the batch of the test. These results prove that Explorer(®) 2.0 coupled to e-Reader(®) is a valuable tool for the screening of a broad range of antimicrobials in muscle. This new methodology simplifies the analysis and increases the accuracy of interpretation of the test results since the endpoint of the assay is automatically determined and results are interpreted objectively.
McGeown, Sarah P; Gray, Eleanor A; Robinson, Jamey L; Dewhurst, Stephen A
2014-06-01
Two experiments investigated the cognitive skills that underlie children's susceptibility to semantic and phonological false memories in the Deese/Roediger-McDermott procedure (Deese, 1959; Roediger & McDermott, 1995). In Experiment 1, performance on the Verbal Similarities subtest of the British Ability Scales (BAS) II (Elliott, Smith, & McCulloch, 1997) predicted correct and false recall of semantic lures. In Experiment 2, performance on the Yopp-Singer Test of Phonemic Segmentation (Yopp, 1988) did not predict correct recall, but inversely predicted the false recall of phonological lures. Auditory short-term memory was a negative predictor of false recall in Experiment 1, but not in Experiment 2. The findings are discussed in terms of the formation of gist and verbatim traces as proposed by fuzzy trace theory (Reyna & Brainerd, 1998) and the increasing automaticity of associations as proposed by associative activation theory (Howe, Wimmer, Gagnon, & Plumpton, 2009). Copyright © 2014 Elsevier B.V. All rights reserved.
The Illusion of the Positive: The impact of natural and induced mood on older adults’ false recall
Emery, Lisa; Hess, Thomas M.; Elliot, Tonya
2012-01-01
Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults’ information processing and potentially increase underlying cognitive age differences. PMID:22292431
The illusion of the positive: the impact of natural and induced mood on older adults' false recall.
Emery, Lisa; Hess, Thomas M; Elliot, Tonya
2012-11-01
Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995 , Journal of Experimental Psychology: Learning, Memory, and Cognition, 21, 803) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults' information processing and potentially increase underlying cognitive age differences.
Validity of HydraTrend reagent strips for the assessment of hydration status.
Abbey, Bryce M; Heelan, Kate A; Brown, Gregory A; Bartee, Rodrick T
2014-09-01
Hydration is used by athletic governing organizations for weight class eligibility. The measurement of urine specific gravity (USG) as a measure of hydration by reagent strips is a controversial issue. The purpose of this study was to determine the validity of HydraTrend reagent strips that facilitate the correction of USG for alkaline urine samples against refractometry for the assessment of USG. Fifty-one participants (33 males, age = 22.3 ± 1.3 years; 18 females, age = 22.4 ± 1.2 years) provided 84 urine samples. The samples were tested for USG using refractometry and reagent strips and for pH using reagent strips and a digital pH meter. Strong correlation coefficients were found between refractometry and reagent strips for USG (rs(82) = 0.812, p < 0.01) and between reagent strips and pH meter for pH (rs(82) = 0.939, p < 0.01). It was observed that false negative results for National Collegiate Athletic Association (NCAA) requirements (fail refractometry with USG >1.020, pass reagent strips with USG ≤1.020) occurred 39% (33/84) of the time and false negative results for National Federation of State High School Association (NFHS) requirements (fail refractometry with USG >1.025, pass reagent strips with USG ≤1.025) occurred 14% (12/84) of the time. There were no false positives (pass refractometry and fail reagent strips) for NCAA or NFHS requirements. These data show that refractometry and reagent strips have strong positive correlations. However, the risk of a false negative result leading to incorrect certification of euhydration status outweighs the benefits of the HydraTrend reagent strips for the measurement of USG.
Comparison of Six Automated Treponema-Specific Antibody Assays.
Park, Borae G; Yoon, Jihoon G; Rim, John Hoon; Lee, Anna; Kim, Hyon-Suk
2016-01-01
Six different Treponema (TP)-specific immunoassays were compared to the fluorescent treponemal antibody absorption (FTA-ABS) test. A total of 615 samples were tested. The overall percent agreement, analytical sensitivity, and analytical specificity of each assay compared to the FTA-ABS test were as follows: Architect Syphilis TP, 99.2%, 96.8%, and 100%; Cobas Syphilis, 99.8%, 99.4%, and 100%; ADVIA Centaur Syphilis, 99.8%, 99.4%, and 100%; HISCL Anti-TP assay kit, 99.7%, 98.7%, and 100%; Immunoticles Auto3 TP, 99.0%, 97.5%, and 99.6%; Mediace TPLA, 98.0%, 98.1%, and 98.0%. All results that were discrepant between the TP-specific assays were associated with samples from noninfectious cases (11 immunoassay false positives and 7 from previous syphilis cases). Our study demonstrated that TP-specific immunoassays generally showed high sensitivities, specificities, and percentages of agreement compared to FTA-ABS, with rare cases of false-positive or false-negative results. Therefore, most TP-specific immunoassays are acceptable for use in screening for syphilis. However, it is important to perform a thorough review of a patient's clinical and treatment history for interpreting the results of syphilis serology. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
High confidence in falsely recognizing prototypical faces.
Sampaio, Cristina; Reinke, Victoria; Mathews, Jeffrey; Swart, Alexandra; Wallinger, Stephen
2018-06-01
We applied a metacognitive approach to investigate confidence in recognition of prototypical faces. Participants were presented with sets of faces constructed digitally as deviations from prototype/base faces. Participants were then tested with a simple recognition task (Experiment 1) or a multiple-choice task (Experiment 2) for old and new items plus new prototypes, and they showed a high rate of confident false alarms to the prototypes. Confidence and accuracy relationship in this face recognition paradigm was found to be positive for standard items but negative for the prototypes; thus, it was contingent on the nature of the items used. The data have implications for lineups that employ match-to-suspect strategies.
Rapid HIV Testing in Dental Practices
Abel, Stephen N.; Pereyra, Margaret; Liguori, Terri; Pollack, Harold A.; Metsch, Lisa R.
2012-01-01
Despite increasing discussion about the dental care setting as a logical, potentially fruitful venue for rapid HIV testing, dentists’ willingness to take on this task is unclear. Semistructured interviews with 40 private practice dentists revealed their principal concerns regarding offering patients HIV testing were false results, offending patients, viewing HIV testing as outside the scope of licensure, anticipating low patient acceptance of HIV testing in a dental setting, expecting inadequate reimbursement, and potential negative impact on the practice. Dentists were typically not concerned about transmission risks, staff opposition to testing, or making referrals for follow-up after a positive result. A larger cultural change may be required to engage dentists more actively in primary prevention and population-based HIV screening. PMID:22397342
Introducing Bayesian thinking to high-throughput screening for false-negative rate estimation.
Wei, Xin; Gao, Lin; Zhang, Xiaolei; Qian, Hong; Rowan, Karen; Mark, David; Peng, Zhengwei; Huang, Kuo-Sen
2013-10-01
High-throughput screening (HTS) has been widely used to identify active compounds (hits) that bind to biological targets. Because of cost concerns, the comprehensive screening of millions of compounds is typically conducted without replication. Real hits that fail to exhibit measurable activity in the primary screen due to random experimental errors will be lost as false-negatives. Conceivably, the projected false-negative rate is a parameter that reflects screening quality. Furthermore, it can be used to guide the selection of optimal numbers of compounds for hit confirmation. Therefore, a method that predicts false-negative rates from the primary screening data is extremely valuable. In this article, we describe the implementation of a pilot screen on a representative fraction (1%) of the screening library in order to obtain information about assay variability as well as a preliminary hit activity distribution profile. Using this training data set, we then developed an algorithm based on Bayesian logic and Monte Carlo simulation to estimate the number of true active compounds and potential missed hits from the full library screen. We have applied this strategy to five screening projects. The results demonstrate that this method produces useful predictions on the numbers of false negatives.
Alpern, Jonathan D; Arbefeville, Sophie S; Vercellotti, Gregory; Ferrieri, Patricia; Green, Jaime S
2017-02-01
Strongyloides stercoralis has the potential to cause accelerated autoinfection in immunocompromised hosts. Screening tests for strongyloidiasis may be falsely negative in the setting of immunosuppression. We report a case of Strongyloides hyperinfection syndrome in a patient with human T-lymphotropic virus type 1-associated T-cell leukemia early after hematopoietic stem cell transplant. The diagnosis was made by stool ova and parasite examination, despite a negative screening enzyme-linked immunosorbent assay. Because of anticipated prolonged neutropenia, an extended course of treatment was utilized. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Causes of false-negative for high-grade urothelial carcinoma in urine cytology.
Lee, Paul J; Owens, Christopher L; Lithgow, Marie Y; Jiang, Zhong; Fischer, Andrew H
2016-12-01
The Paris System for classifying urine cytology emphasizes identification of high-grade urothelial carcinoma (HGUC). The causes of false-negative urine cytologies (UC) within this system are not well described. We identified 660 cases between 2005 and 2013 with both UC and subsequent cystoscopic biopsies. UC were classified as either Negative for HGUC or "Abnormal" ("Atypical", "Suspicious", and "Malignant"). Apparent false-negative cases were reviewed in a nonblinded fashion by two cytopathologists and two subspecialized genitourinary pathologists. A total of 199 of the 660 cases (30%) were histologically diagnosed as HGUC. The UC were "Abnormal" in 170/199 cases (sensitivity/specificity of 86%/71%). Twenty four apparent false negative cases were available for retrospective review. Five of 24 (21%) cystoscopic biopsies were found not to be HGUC on review (one false positive and four low-grade urothelial carcinoma (LGUC on review). Of the remaining 19 UC, 7 (29%) cytology samples were found to be truly negative on review, 11 (46%) were found to be Atypical, and 1 (4%) suspicious. Of the 12 UC that were at least "Atypical" with histologic HGUC on review: six misses (half) were attributed to obscuring inflammation/blood, four to poor preservation, eight to paucity of abnormal cells, and 1 case to interpretive error; many cases demonstrated overlapping reasons. About one fifth of apparent false negative diagnoses for HGUC can be because of overdiagnosis of HGUC by surgical pathologists. If poor preservation or obscured samples are called nondiagnostic, the sensitivity/specificity of UC for HGUC can be as high as 94%/71%. Diagn. Cytopathol. 2016;44:994-999. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Mir, Nuria; Sánchez, Miguel; Baquero, Fernando; López, Blanca; Calderón, Celia; Cantón, Rafael
1998-01-01
The early detection of colonization with methicillin-resistant Staphylococcus aureus (MRSA) of patients in intensive-care units is an essential step in the strategy for preventing MRSA epidemics. In this study, tubes containing soft salt-mannitol agar with cloxacillin (6 μg/ml) (SSMAC) were prepared for inoculation of clinical samples at patients’ bedsides by personnel of an intensive-care unit. A total of 1,914 swabs from different sample sites of 81 patients were dipped into SSMAC tubes, and after 24 h of incubation (in an incubator located near the intensive-care unit), an evident color change was considered by the intensive-care-unit personnel to be an MRSA alarm. Sixty-three (3.3%) SSMAC tubes were considered positive for MRSA, 1,827 (95.4%) were considered negative, and 24 (1.2%) were considered intermediate. Compared with values for parallel conventional surveillance cultures for MRSA, excluding tubes with intermediate results, the SSMAC test had a sensitivity of 72.7%, a specificity of 99.2%, a positive predictive value of 76.2%, and a negative predictive value of 99.0%. When intermediate tubes were considered positive, the corresponding values were 75.3, 98.2, 63.2, and 99.0%, respectively. The sensitivity and specificity values of the test to identify MRSA-colonized patients were 89.4 and 100%, respectively. Oropharyngeal and naris specimens were the most reliable samples for MRSA detection. False-negative results were frequent in bronchial aspirates with low (<103 to 106 CFU/ml) MRSA counts. False-positive results were mainly due to methicillin-resistant Staphylococcus haemolyticus. The SSMAC tube is a useful, rapid, and inexpensive tool for the early identification of MRSA-colonized patients and, consequently, for the implementation of measures to prevent the spread of MRSA. PMID:9542922
Zahradnik, Celine; Kolm, Claudia; Martzy, Roland; Mach, Robert L; Krska, Rudolf; Farnleitner, Andreas H; Brunner, Kurt
2014-11-01
In 2003 the European Commission introduced a 0.9% threshold for food and feed products containing genetically modified organism (GMO)-derived components. For commodities containing GMO contents higher than this threshold, labelling is mandatory. To provide a DNA-based rapid and simple detection method suitable for high-throughput screening of GMOs, several isothermal amplification approaches for the 35S promoter were tested: strand displacement amplification, nicking-enzyme amplification reaction, rolling circle amplification, loop-mediated isothermal amplification (LAMP) and helicase-dependent amplification (HDA). The assays developed were tested for specificity in order to distinguish between samples containing genetically modified (GM) maize and non-GM maize. For those assays capable of this discrimination, tests were performed to determine the lower limit of detection. A false-negative rate was determined to rule out whether GMO-positive samples were incorrectly classified as GMO-negative. A robustness test was performed to show reliable detection independent from the instrument used for amplification. The analysis of three GM maize lines showed that only LAMP and HDA were able to differentiate between the GMOs MON810, NK603, and Bt11 and non-GM maize. Furthermore, with the HDA assay it was possible to realize a detection limit as low as 0.5%. A false-negative rate of only 5% for 1% GM maize for all three maize lines shows that HDA has the potential to be used as an alternative strategy for the detection of transgenic maize. All results obtained with the LAMP and HDA assays were compared with the results obtained with a previously reported real-time PCR assay for the 35S promoter in transgenic maize. This study presents two new screening assays for detection of the 35S promoter in transgenic maize by applying the isothermal amplification approaches HDA and LAMP.
1981-01-01
Gas production by coliform organisms and Escherichia coli from lauryl tryptose lactose broth (LTLB) was compared with that from brilliant green (lactose) bile broth (BGB). These media were compared with lauryl tryptose mannitol broth (LTMB) with and without added tryptophan for both gas and indole production. At 37 degrees C, LTLB and BGB were both satisfactory for gas production, but at 44 degrees C, LTLB gave fewer false-negative results and was thus significantly less inhibitory than BGB. However when LTLB and LTMB were compared as single-tube confirmatory media, LTLB give a high proportion of false-negative reactions in the indole test at 44 degrees C. The substitution of mannitol for lactose and the addition of tryptophan yielded a satisfactory medium for both confirmation of gas production and the demonstration of indole at 44 degrees C. PMID:7031125