Hundhausen, T; Müller, T H
2005-08-01
The microbial detection system BacT/ALERT (bioMérieux) is widely used to monitor bacterial contamination of platelet concentrates (PCs). Recently, the manufacturer introduced polycarbonate culture bottles and a modified pH-sensitive liquid emulsion sensor as microbial growth indicator. This reconfigured assay was investigated in a routine setting. In each of eight transfusion centers, samples from 500 consecutive PCs were monitored for 1 week. For all PCs with a positive BacT/ALERT signal, retained samples and, if available, original PC containers and concomitant red blood cell concentrates were analyzed independently. Initially BacT/ALERT-positive PCs without bacterial identification in any sample were defined as false-positive. BacT/ALERT-positive PCs with bacteria in the first sample only were called potentially positive. PCs with bacteria in the first sample and the same strain in at least one additional sample were accepted as positive. Five PCs (0.13%) were positive, 9 PCs (0.23%) were potentially positive, and 35 PCs (0.9%) were false-positive. The rate of false-positive BacT/ALERT results varied substantially between centers (<0.2%-3.2%). Tracings from false-positive cultures lacked an exponential increase of the signal during incubation. Most of these false-positives were due to malfunctioning cells in various BacT/ALERT incubation units. Careful assessment of individual tracings of samples with positive signals helps to identify malfunctioning incubation units. Their early shutdown or replacement minimizes the high rate of unrectifiable product rejects attributed to false-positive alarms and avoids unnecessary concern of doctors and patients after conversion to a reconfigured BacT/ALERT assay.
Visual field progression in glaucoma: what is the specificity of the Guided Progression Analysis?
Artes, Paul H; O'Leary, Neil; Nicolela, Marcelo T; Chauhan, Balwantray C; Crabb, David P
2014-10-01
To estimate the specificity of the Guided Progression Analysis (GPA) (Carl Zeiss Meditec, Dublin, CA) in individual patients with glaucoma. Observational cohort study. Thirty patients with open-angle glaucoma. In 30 patients with open-angle glaucoma, 1 eye (median mean deviation [MD], -2.5 decibels [dB]; interquartile range, -4.4 to -1.3 dB) was tested 12 times over 3 months (Humphrey Field Analyzer, Carl Zeiss Meditec; SITA Standard, 24-2). "Possible progression" and "likely progression" were determined with the GPA. These analyses were repeated after the order of the tests had been randomly rearranged (1000 unique permutations). Rate of false-positive alerts of "possible progression" and "likely progression" with the GPA. On average, the specificity of the GPA "likely progression" alert was high-for the entire sample, the mean rate of false-positive alerts after 10 follow-up tests was 2.6%. With "possible progression," the specificity was considerably lower (false-positive rate, 18.5%). Most important, the cumulative rate of false-positive alerts varied substantially among patients, from <1% to 80% with "possible progression" and from <0.1% to 20% with "likely progression." Factors associated with false-positive alerts were visual field variability (standard deviation of MD, Spearman's rho = 0.41, P<0.001) and the reliability indices (proportion of false-positive and false-negative responses, fixation losses, rho>0.31, P≤0.10). On average, progression criteria currently used in the GPA have high specificity, but some patients are more likely to show false-positive alerts than others. This is a natural consequence of population-based change criteria and may not matter in clinical trials and studies in which large groups of patients are compared. However, it must be considered when the GPA is used in clinical practice where specificity needs to be controlled for individual patients. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Larsen, C P; Ezligini, F; Hermansen, N O; Kjeldsen-Kragh, J
2005-02-01
Approximately 1 in every 2000 units of platelets is contaminated with bacteria. The BacT/ALERT automated blood culture system can be used to screen platelet concentrates (PCs) for bacterial contamination. Data were collected from May 1998 until May 2004. The number of PCs tested during this period was 36 896, most of which were produced from pools of four buffy-coats. On the day following blood collection or platelet apheresis, a 5-10 ml sample of the PC was aseptically transferred to a BacT/ALERT culture bottle for detection of aerobic bacteria. The sample was monitored for bacterial growth during the entire storage period of the PC (6.5 days). When a positive signal was generated, the culture bottle, the PC and the erythrocyte concentrates were tested for bacterial growth. In order to determine the frequency of false-negative BacT/ALERT signals, 1061 outdated PCs were tested during the period from May 2002 to May 2004. Eighty-eight positive signals were detected by the BacT/ALERT system, of which 12 were interpreted as truly positive. Fourteen signals were interpreted as truly false positive. Thirty-three signals were interpreted to be probably false positive. Two of 1061 outdated units tested positive, and Bacillus spp. and Staphylococcus epidermidis, respectively, were isolated from these PCs. Between 0.03% and 0.12% of the PCs were contaminated with bacteria. BacT/ALERT is an efficient tool for monitoring PCs for bacterial contamination; however, it is important to realize that false-negative results may occur.
Evaluating Alerting and Guidance Performance of a UAS Detect-And-Avoid System
NASA Technical Reports Server (NTRS)
Lee, Seung Man; Park, Chunki; Thipphavong, David P.; Isaacson, Douglas R.; Santiago, Confesor
2016-01-01
A key challenge to the routine, safe operation of unmanned aircraft systems (UAS) is the development of detect-and-avoid (DAA) systems to aid the UAS pilot in remaining "well clear" of nearby aircraft. The goal of this study is to investigate the effect of alerting criteria and pilot response delay on the safety and performance of UAS DAA systems in the context of routine civil UAS operations in the National Airspace System (NAS). A NAS-wide fast-time simulation study was conducted to assess UAS DAA system performance with a large number of encounters and a broad set of DAA alerting and guidance system parameters. Three attributes of the DAA system were controlled as independent variables in the study to conduct trade-off analyses: UAS trajectory prediction method (dead-reckoning vs. intent-based), alerting time threshold (related to predicted time to LoWC), and alerting distance threshold (related to predicted Horizontal Miss Distance, or HMD). A set of metrics, such as the percentage of true positive, false positive, and missed alerts, based on signal detection theory and analysis methods utilizing the Receiver Operating Characteristic (ROC) curves were proposed to evaluate the safety and performance of DAA alerting and guidance systems and aid development of DAA system performance standards. The effect of pilot response delay on the performance of DAA systems was evaluated using a DAA alerting and guidance model and a pilot model developed to support this study. A total of 18 fast-time simulations were conducted with nine different DAA alerting threshold settings and two different trajectory prediction methods, using recorded radar traffic from current Visual Flight Rules (VFR) operations, and supplemented with DAA-equipped UAS traffic based on mission profiles modeling future UAS operations. Results indicate DAA alerting distance threshold has a greater effect on DAA system performance than DAA alerting time threshold or ownship trajectory prediction method. Further analysis on the alert lead time (time in advance of predicted loss of well clear at which a DAA alert is first issued) indicated a strong positive correlation between alert lead time and DAA system performance (i.e. the ability of the UAS pilot to maneuver the unmanned aircraft to remain well clear). While bigger distance thresholds had beneficial effects on alert lead time and missed alert rate, it also generated a higher rate of false alerts. In the design and development of DAA alerting and guidance systems, therefore, the positive and negative effects of false alerts and missed alerts should be carefully considered to achieve acceptable alerting system performance by balancing false and missed alerts. The results and methodology presented in this study are expected to help stakeholders, policymakers and standards committees define the appropriate setting of DAA system parameter thresholds for UAS that ensure safety while minimizing operational impacts to the NAS and equipage requirements for its users before DAA operational performance standards can be finalized.
Zhu, Li-Wei; Yang, Xue-Mei; Xu, Xiao-Qin; Xu, Jian; Lu, Huang-Jun; Yan, Li-Xing
2008-10-01
This study was aimed to analyze the results of false positive reaction in bacterial detection of blood samples with BacT/ALERT 3D system, to evaluate the specificity of this system, and to decrease the false positive reaction. Each reaction flasks in past five years were processed for bacteria isolation and identification. When the initial cultures were positive, the remaining samples and the corresponding units were recultured if still available. 11395 blood samples were detected. It is worthy of note that the incubator temperature should be stabilized, avoiding fluctuation; when the cultures were alarmed, the reaction flasks showed be kept some hours for further incubation so as to trace a sharply increasing signal to support the judgement of true bacterial growth. The results indicated that 122 samples (1.07%) wee positive at initial culture, out of them 107 samples (88.7%) were found bacterial, and 15 samples (12.3%) were found nothing. The detection curves of positive samples resulted from bacterial growth showed ascent. In conclusion, maintenance of temperature stability and avoidance of temperature fluctuation in incubator could decrease the occurrence of false-positive reaction in detection process. The reaction flasks with positive results at initial culture should be recultured, and whether existence of a sharply ascending logarilhimic growth phase in bacterial growth curve should be further detected, which are helpful to distinguish false-positive reactions from true positive, and thus increase the specificity of the BacT/ALERT system.
Martín, Ana; Herranz, Marta; Lirola, Miguel Martínez; Fernández, Rosa Fernández; Bouza, Emilio; García de Viedma, Darío
2008-02-14
The phenomenon of misdiagnosing tuberculosis (TB) by laboratory cross-contamination when culturing Mycobacterium tuberculosis (MTB) has been widely reported and it has an obvious clinical, therapeutic and social impact. The final confirmation of a cross-contamination event requires the molecular identification of the same MTB strain cultured from both the potential source of the contamination and from the false-positive candidate. The molecular tool usually applied in this context is IS6110-RFLP which takes a long time to provide an answer, usually longer than is acceptable for microbiologists and clinicians to make decisions. Our purpose in this study is to evaluate a novel PCR-based method, MIRU-VNTR as an alternative to assure a rapid and optimized analysis of cross-contamination alerts. MIRU-VNTR was prospectively compared with IS6110-RFLP for clarifying 19 alerts of false positivity from other laboratories. MIRU-VNTR highly correlated with IS6110-RFLP, reduced the response time by 27 days and clarified six alerts unresolved by RFLP. Additionally, MIRU-VNTR revealed complex situations such as contamination events involving polyclonal isolates and a false-positive case due to the simultaneous cross-contamination from two independent sources. Unlike standard RFLP-based genotyping, MIRU-VNTR i) could help reduce the impact of a false positive diagnosis of TB, ii) increased the number of events that could be solved and iii) revealed the complexity of some cross-contamination events that could not be dissected by IS6110-RFLP.
Kundnani, Vishal K; Zhu, Lisa; Tak, HH; Wong, HK
2010-01-01
Background: Multimodal intraoperative neuromonitoring is recommended during corrective spinal surgery, and has been widely used in surgery for spinal deformity with successful outcomes. Despite successful outcomes of corrective surgery due to increased safety of the patients with the usage of spinal cord monitoring in many large spine centers, this modality has not yet achieved widespread popularity. We report the analysis of prospectively collected intraoperative neurophysiological monitoring data of 354 consecutive patients undergoing corrective surgery for adolescent idiopathic scoliosis (AIS) to establish the efficacy of multimodal neuromonitoring and to evaluate comparative sensitivity and specificity. Materials and Methods: The study group consisted of 354 (female = 309; male = 45) patients undergoing spinal deformity corrective surgery between 2004 and 2008. Patients were monitored using electrophysiological methods including somatosensory-evoked potentials and motor-evoked potentials simultaneously. Results: Mean age of patients was 13.6 years (±2.3 years). The operative procedures involved were instrumented fusion of the thoracic/lumbar/both curves, Baseline somatosensory-evoked potentials (SSEP) and neurogenic motor-evoked potentials (NMEP) were recorded successfully in all cases. Thirteen cases expressed significant alert to prompt reversal of intervention. All these 13 cases with significant alert had detectable NMEP alerts, whereas significant SSEP alert was detected in 8 cases. Two patients awoke with new neurological deficit (0.56%) and had significant intraoperative SSEP + NMEP alerts. There were no false positives with SSEP (high specificity) but 5 patients with false negatives with SSEP (38%) reduced its sensitivity. There was no false negative with NMEP but 2 of 13 cases were false positive with NMEP (15%). The specificity of SSEP (100%) is higher than NMEP (96%); however, the sensitivity of NMEP (100%) is far better than SSEP (51%). Due to these results, the overall sensitivity, specificity and positive predictive value of combined multimodality neuromonitoring in this adult deformity series was 100, 98.5 and 85%, respectively. Conclusion: Neurogenic motor-evoked potential (NMEP) monitoring appears to be superior to conventional SSEP monitoring for identifying evolving spinal cord injury. Used in conjunction, the sensitivity and specificity of combined neuromonitoring may reach up to 100%. Multimodality monitoring with SSEP + NMEP should be the standard of care. PMID:20165679
Sethuraman, Usha; Kannikeswaran, Nirupama; Murray, Kyle P; Zidan, Marwan A; Chamberlain, James M
2015-06-01
Prescription errors occur frequently in pediatric emergency departments (PEDs).The effect of computerized physician order entry (CPOE) with electronic medication alert system (EMAS) on these is unknown. The objective was to compare prescription errors rates before and after introduction of CPOE with EMAS in a PED. The hypothesis was that CPOE with EMAS would significantly reduce the rate and severity of prescription errors in the PED. A prospective comparison of a sample of outpatient, medication prescriptions 5 months before and after CPOE with EMAS implementation (7,268 before and 7,292 after) was performed. Error types and rates, alert types and significance, and physician response were noted. Medication errors were deemed significant if there was a potential to cause life-threatening injury, failure of therapy, or an adverse drug effect. There was a significant reduction in the errors per 100 prescriptions (10.4 before vs. 7.3 after; absolute risk reduction = 3.1, 95% confidence interval [CI] = 2.2 to 4.0). Drug dosing error rates decreased from 8 to 5.4 per 100 (absolute risk reduction = 2.6, 95% CI = 1.8 to 3.4). Alerts were generated for 29.6% of prescriptions, with 45% involving drug dose range checking. The sensitivity of CPOE with EMAS in identifying errors in prescriptions was 45.1% (95% CI = 40.8% to 49.6%), and the specificity was 57% (95% CI = 55.6% to 58.5%). Prescribers modified 20% of the dosing alerts, resulting in the error not reaching the patient. Conversely, 11% of true dosing alerts for medication errors were overridden by the prescribers: 88 (11.3%) resulted in medication errors, and 684 (88.6%) were false-positive alerts. A CPOE with EMAS was associated with a decrease in overall prescription errors in our PED. Further system refinements are required to reduce the high false-positive alert rates. © 2015 by the Society for Academic Emergency Medicine.
Wang, Ruiping; Jiang, Yonggen; Guo, Xiaoqin; Wu, Yiling; Zhao, Genming
2017-01-01
Objective The Chinese Center for Disease Control and Prevention developed the China Infectious Disease Automated-alert and Response System (CIDARS) in 2008. The CIDARS can detect outbreak signals in a timely manner but generates many false-positive signals, especially for diseases with seasonality. We assessed the influence of seasonality on infectious disease outbreak detection performance. Methods Chickenpox surveillance data in Songjiang District, Shanghai were used. The optimized early alert thresholds for chickenpox were selected according to three algorithm evaluation indexes: sensitivity (Se), false alarm rate (FAR), and time to detection (TTD). Performance of selected proper thresholds was assessed by data external to the study period. Results The optimized early alert threshold for chickenpox during the epidemic season was the percentile P65, which demonstrated an Se of 93.33%, FAR of 0%, and TTD of 0 days. The optimized early alert threshold in the nonepidemic season was P50, demonstrating an Se of 100%, FAR of 18.94%, and TTD was 2.5 days. The performance evaluation demonstrated that the use of an optimized threshold adjusted for seasonality could reduce the FAR and shorten the TTD. Conclusions Selection of optimized early alert thresholds based on local infectious disease seasonality could improve the performance of the CIDARS. PMID:28728470
Wang, Ruiping; Jiang, Yonggen; Guo, Xiaoqin; Wu, Yiling; Zhao, Genming
2018-01-01
Objective The Chinese Center for Disease Control and Prevention developed the China Infectious Disease Automated-alert and Response System (CIDARS) in 2008. The CIDARS can detect outbreak signals in a timely manner but generates many false-positive signals, especially for diseases with seasonality. We assessed the influence of seasonality on infectious disease outbreak detection performance. Methods Chickenpox surveillance data in Songjiang District, Shanghai were used. The optimized early alert thresholds for chickenpox were selected according to three algorithm evaluation indexes: sensitivity (Se), false alarm rate (FAR), and time to detection (TTD). Performance of selected proper thresholds was assessed by data external to the study period. Results The optimized early alert threshold for chickenpox during the epidemic season was the percentile P65, which demonstrated an Se of 93.33%, FAR of 0%, and TTD of 0 days. The optimized early alert threshold in the nonepidemic season was P50, demonstrating an Se of 100%, FAR of 18.94%, and TTD was 2.5 days. The performance evaluation demonstrated that the use of an optimized threshold adjusted for seasonality could reduce the FAR and shorten the TTD. Conclusions Selection of optimized early alert thresholds based on local infectious disease seasonality could improve the performance of the CIDARS.
47 CFR 80.334 - False distress alerts.
Code of Federal Regulations, 2013 CFR
2013-10-01
....S. Coast Guard; (d) Was repeated; or (e) Was transmitted using a false identity. [68 FR 46968, Aug... § 80.334 False distress alerts. A distress alert is false if it was transmitted without any indication that a mobile unit or person was in distress and required immediate assistance. Transmitting a false...
47 CFR 80.334 - False distress alerts.
Code of Federal Regulations, 2014 CFR
2014-10-01
....S. Coast Guard; (d) Was repeated; or (e) Was transmitted using a false identity. [68 FR 46968, Aug... § 80.334 False distress alerts. A distress alert is false if it was transmitted without any indication that a mobile unit or person was in distress and required immediate assistance. Transmitting a false...
47 CFR 80.334 - False distress alerts.
Code of Federal Regulations, 2011 CFR
2011-10-01
....S. Coast Guard; (d) Was repeated; or (e) Was transmitted using a false identity. [68 FR 46968, Aug... § 80.334 False distress alerts. A distress alert is false if it was transmitted without any indication that a mobile unit or person was in distress and required immediate assistance. Transmitting a false...
47 CFR 80.334 - False distress alerts.
Code of Federal Regulations, 2010 CFR
2010-10-01
....S. Coast Guard; (d) Was repeated; or (e) Was transmitted using a false identity. [68 FR 46968, Aug... § 80.334 False distress alerts. A distress alert is false if it was transmitted without any indication that a mobile unit or person was in distress and required immediate assistance. Transmitting a false...
47 CFR 80.334 - False distress alerts.
Code of Federal Regulations, 2012 CFR
2012-10-01
....S. Coast Guard; (d) Was repeated; or (e) Was transmitted using a false identity. [68 FR 46968, Aug... § 80.334 False distress alerts. A distress alert is false if it was transmitted without any indication that a mobile unit or person was in distress and required immediate assistance. Transmitting a false...
Final Report: Computer-aided Human Centric Cyber Situation Awareness
2016-03-20
logs, OS audit trails, vulnerability reports, and packet dumps ), weeding out the false positives, grouping the related indicators so that different...short time duration of each visual stimulus in an fMRI study, we have designed “network security analysis cards ” that require the subject to...determine whether alerts in the cards indicate malicious events. Two types of visual displays of alerts (i.e., tabular display and node-link display) are
A framework for evaluating the appropriateness of clinical decision support alerts and responses
Waitman, Lemuel R; Lewis, Julia B; Wright, Julie A; Choma, David P; Miller, Randolph A; Peterson, Josh F
2011-01-01
Objective Alerting systems, a type of clinical decision support, are increasingly prevalent in healthcare, yet few studies have concurrently measured the appropriateness of alerts with provider responses to alerts. Recent reports of suboptimal alert system design and implementation highlight the need for better evaluation to inform future designs. The authors present a comprehensive framework for evaluating the clinical appropriateness of synchronous, interruptive medication safety alerts. Methods Through literature review and iterative testing, metrics were developed that describe successes, justifiable overrides, provider non-adherence, and unintended adverse consequences of clinical decision support alerts. The framework was validated by applying it to a medication alerting system for patients with acute kidney injury (AKI). Results Through expert review, the framework assesses each alert episode for appropriateness of the alert display and the necessity and urgency of a clinical response. Primary outcomes of the framework include the false positive alert rate, alert override rate, provider non-adherence rate, and rate of provider response appropriateness. Application of the framework to evaluate an existing AKI medication alerting system provided a more complete understanding of the process outcomes measured in the AKI medication alerting system. The authors confirmed that previous alerts and provider responses were most often appropriate. Conclusion The new evaluation model offers a potentially effective method for assessing the clinical appropriateness of synchronous interruptive medication alerts prior to evaluating patient outcomes in a comparative trial. More work can determine the generalizability of the framework for use in other settings and other alert types. PMID:21849334
Evaluation of negative results of BacT/Alert 3D automated blood culture system.
Kocoglu, M Esra; Bayram, Aysen; Balci, Iclal
2005-06-01
Although automated continuous-monitoring blood culture systems are both rapid and sensitive, false-positive and false-negative results still occur. The objective of this study, then, was to evaluate negative results occurring with BacT/Alert 3D blood culture systems. A total of 1032 samples were cultured with the BacT/Alert 3D automated blood culture system, using both aerobic (FA) and anaerobic (FN) [corrected] media, and 128 of these samples yielded positive results. A total of 904 negative blood samples were then subcultured in 5% sheep blood agar, eosin methylene blue, chocolate agar, and sabouraud-dextrose agar. Organisms growing on these subcultures were subsequently identified using both Vitek32 (bioMerieux, Durham, NC) and conventional methods. Twenty four (2.6%) of the 904 subcultures grew on the subculture media. The majority (83.3%) of these were determined to be gram-positive microorganisms. Fourteen (58.3%) were coagulase-negative staphylococci, two (8.3%) were Bacillus spp., one (4.2%) was Staphylococcus aureus, and one (4.2%) was identified as Enterococcus faecium. Streptococcus pneumoniae and Neisseria spp. were isolated together in two (8.3%) vials. Gram-negative microorganisms comprised 12.5% of the subcultures, of which two (8.3%) were found to be Pseudomonas aeruginosa, and one (4.2%) was Pseudomonas fluorescens. The other isolate (4.2%) was identified as Candida albicans. We conclude that the subculture of negative results is valuable in the BacT/Alert 3D system, especially in situations in which only one set of blood cultures is taken.
[Automated detection of estrus and mastitis in dairy cows].
de Mol, R M
2001-02-15
The development and test of detection models for oestrus and mastitis in dairy cows is described in a PhD thesis that was defended in Wageningen on June 5, 2000. These models were based on sensors for milk yield, milk temperature, electrical conductivity of milk, and cow activity and concentrate intake, and on combined processing of the sensor data. The models alert farmers to cows that need attention, because of possible oestrus or mastitis. A first detection model for cows, milked twice a day, was based on time series models for the sensor variables. A time series model describes the dependence between successive observations. The parameters of the time series models were fitted on-line for each cow after each milking by means of a Kalman filter, a mathematical method to estimate the state of a system on-line. The Kalman filter gives the best estimate of the current state of a system based on all preceding observations. This model was tested for 2 years on two experimental farms, and under field conditions on four farms over several years. A second detection model, for cow milked in an automatic milking system (AMS), was based on a generalization of the first model. Two data sets (one small, one large) were used for testing. The results for oestrus detection were good for both models. The results for mastitis detection were varying (in some cases good, in other cases moderate). Fuzzy logic was used to classify mastitis and oestrus alerts with both detection models, to reduce the number of false positive alerts. Fuzzy logic makes approximate reasoning possible, where statements can be partly true or false. Input for the fuzzy logic model were alerts from the detection models and additional information. The number of false positive alerts decreased considerably, while the number of detected cases remained at the same level. These models make automated detection possible in practice.
Perceptual evaluation of visual alerts in surveillance videos
NASA Astrophysics Data System (ADS)
Rogowitz, Bernice E.; Topkara, Mercan; Pfeiffer, William; Hampapur, Arun
2015-03-01
Visual alerts are commonly used in video monitoring and surveillance systems to mark events, presumably making them more salient to human observers. Surprisingly, the effectiveness of computer-generated alerts in improving human performance has not been widely studied. To address this gap, we have developed a tool for simulating different alert parameters in a realistic visual monitoring situation, and have measured human detection performance under conditions that emulated different set-points in a surveillance algorithm. In the High-Sensitivity condition, the simulated alerts identified 100% of the events with many false alarms. In the Lower-Sensitivity condition, the simulated alerts correctly identified 70% of the targets, with fewer false alarms. In the control condition, no simulated alerts were provided. To explore the effects of learning, subjects performed these tasks in three sessions, on separate days, in a counterbalanced, within subject design. We explore these results within the context of cognitive models of human attention and learning. We found that human observers were more likely to respond to events when marked by a visual alert. Learning played a major role in the two alert conditions. In the first session, observers generated almost twice as many False Alarms as in the No-Alert condition, as the observers responded pre-attentively to the computer-generated false alarms. However, this rate dropped equally dramatically in later sessions, as observers learned to discount the false cues. Highest observer Precision, Hits/(Hits + False Alarms), was achieved in the High Sensitivity condition, but only after training. The successful evaluation of surveillance systems depends on understanding human attention and performance.
Variability of Diabetes Alert Dog Accuracy in a Real-World Setting
Gonder-Frederick, Linda A.; Grabman, Jesse H.; Shepard, Jaclyn A.; Tripathi, Anand V.; Ducar, Dallas M.; McElgunn, Zachary R.
2017-01-01
Background: Diabetes alert dogs (DADs) are growing in popularity as an alternative method of glucose monitoring for individuals with type 1 diabetes (T1D). Only a few empirical studies have assessed DAD accuracy, with inconsistent results. The present study examined DAD accuracy and variability in performance in real-world conditions using a convenience sample of owner-report diaries. Method: Eighteen DAD owners (44.4% female; 77.8% youth) with T1D completed diaries of DAD alerts during the first year after placement. Diary entries included daily BG readings and DAD alerts. For each DAD, percentage hits (alert with BG ≤ 5.0 or ≥ 11.1 mmol/L; ≤90 or ≥200 mg/dl), percentage misses (no alert with BG out of range), and percentage false alarms (alert with BG in range) were computed. Sensitivity, specificity, positive likelihood ratio (PLR), and true positive rates were also calculated. Results: Overall comparison of DAD Hits to Misses yielded significantly more Hits for both low and high BG. Total sensitivity was 57.0%, with increased sensitivity to low BG (59.2%) compared to high BG (56.1%). Total specificity was 49.3% and PLR = 1.12. However, high variability in accuracy was observed across DADs, with low BG sensitivity ranging from 33% to 100%. Number of DADs achieving ≥ 60%, 65% and 70% true positive rates was 71%, 50% and 44%, respectively. Conclusions: DADs may be able to detect out-of-range BG, but variability across DADs is evident. Larger trials are needed to further assess DAD accuracy and to identify factors influencing the complexity of DAD accuracy in BG detection. PMID:28627305
The Diagnostic Utility of Bact/ALERT and Nested PCR in the Diagnosis of Tuberculous Meningitis.
Sastry, Apurba Sankar; Bhat K, Sandhya; Kumudavathi
2013-01-01
The early laboratory diagnosis of Tuberculous Meningitis (TBM) is crucial, to start the antitubercular chemotherapy and to prevent its complications. However, the conventional methods are either less sensitive or time consuming. Hence, the diagnostic potentials of BacT/ALERT and Polymerase Chain Reaction (PCR) was evaluated in this study. The study group comprised of 62 cases and 33 controls. The cases were divided according to Ahuja's criteria into the confirmed (two cases), highly probable (19 cases), probable (26 cases) and the possible (15 cases) subgroups. Ziehl Neelsen's (ZN) and Auramine Phenol (AP) staining, Lowenstein Jensen (LJ) medium culture, BacT/ALERT and nested Polymerase Chain Reaction (PCR) which targeted IS6110 were carried out on all the patients. The sensitivity of the LJ culture was 3.22%. BacT/ALERT showed a sensitivity and a specificity of 25.80% and 100% and those of nested PCR were found to be 40.32% and 96.97% respectively. The mean detection time of growth of the LJ culture was 31.28 days, whereas that of BacT/ALERT was 20.68 days. The contamination rate in the LJ culture and BacT/ALERT were 7.2% and 5.8% respectively. Nested PCR was found to be more sensitive, followed by BacT/ALERT as compared to the LJ culture and smear microscopy. As both false negative and false positive results have been reported for nested PCR, so it should not be used alone as a criterion for initiating or terminating the therapy, but it should be supported by clinical, radiological, cytological and other microbiological findings.
Feature-based alert correlation in security systems using self organizing maps
NASA Astrophysics Data System (ADS)
Kumar, Munesh; Siddique, Shoaib; Noor, Humera
2009-04-01
The security of the networks has been an important concern for any organization. This is especially important for the defense sector as to get unauthorized access to the sensitive information of an organization has been the prime desire for cyber criminals. Many network security techniques like Firewall, VPN Concentrator etc. are deployed at the perimeter of network to deal with attack(s) that occur(s) from exterior of network. But any vulnerability that causes to penetrate the network's perimeter of defense, can exploit the entire network. To deal with such vulnerabilities a system has been evolved with the purpose of generating an alert for any malicious activity triggered against the network and its resources, termed as Intrusion Detection System (IDS). The traditional IDS have still some deficiencies like generating large number of alerts, containing both true and false one etc. By automatically classifying (correlating) various alerts, the high-level analysis of the security status of network can be identified and the job of network security administrator becomes much easier. In this paper we propose to utilize Self Organizing Maps (SOM); an Artificial Neural Network for correlating large amount of logged intrusion alerts based on generic features such as Source/Destination IP Addresses, Port No, Signature ID etc. The different ways in which alerts can be correlated by Artificial Intelligence techniques are also discussed. . We've shown that the strategy described in the paper improves the efficiency of IDS by better correlating the alerts, leading to reduced false positives and increased competence of network administrator.
Adaptive Trajectory Prediction Algorithm for Climbing Flights
NASA Technical Reports Server (NTRS)
Schultz, Charles Alexander; Thipphavong, David P.; Erzberger, Heinz
2012-01-01
Aircraft climb trajectories are difficult to predict, and large errors in these predictions reduce the potential operational benefits of some advanced features for NextGen. The algorithm described in this paper improves climb trajectory prediction accuracy by adjusting trajectory predictions based on observed track data. It utilizes rate-of-climb and airspeed measurements derived from position data to dynamically adjust the aircraft weight modeled for trajectory predictions. In simulations with weight uncertainty, the algorithm is able to adapt to within 3 percent of the actual gross weight within two minutes of the initial adaptation. The root-mean-square of altitude errors for five-minute predictions was reduced by 73 percent. Conflict detection performance also improved, with a 15 percent reduction in missed alerts and a 10 percent reduction in false alerts. In a simulation with climb speed capture intent and weight uncertainty, the algorithm improved climb trajectory prediction accuracy by up to 30 percent and conflict detection performance, reducing missed and false alerts by up to 10 percent.
Brassel, J; Rohrssen, F; Failing, K; Wehrend, A
2018-06-11
To evaluate the performance of a novel accelerometer-based oestrus detection system (ODS) for dairy cows on pasture, in comparison with measurement of concentrations of progesterone in milk, ultrasonographic examination of ovaries and farmer observations. Mixed-breed lactating dairy cows (n=109) in a commercial, seasonal-calving herd managed at pasture under typical farming conditions in Ireland, were fitted with oestrus detection collars 3 weeks prior to mating start date. The ODS performed multimetric analysis of eight different motion patterns to generate oestrus alerts. Data were collected during the artificial insemination period of 66 days, commencing on 16 April 2015. Transrectal ultrasonographic examinations of the reproductive tract and measurements of concentrations of progesterone in milk were used to confirm oestrus events. Visual observations by the farmer and the number of theoretically expected oestrus events were used to evaluate the number of false negative ODS alerts. The percentage of eligible cows that were detected in oestrus at least once (and were confirmed true positives) was calculated for the first 21, 42 and 63 days of the insemination period. During the insemination period, the ODS generated 194 oestrus alerts and 140 (72.2%) were confirmed as true positives. Six confirmed oestrus events recognised by the farmer did not generate ODS alerts. The positive predictive value of the ODS was 72.2 (95% CI=65.3-78.4)%. To account for oestrus events not identified by the ODS or the farmer, four theoretical missed oestrus events were added to the false negatives. Estimated sensitivity of the automated ODS was 93.3 (95% CI=88.1-96.8)%. The proportion of eligible cows that were detected in oestrus during the first 21 days of the insemination period was 92/106 (86.8%), and during the first 42 and 63 days of the insemination period was 103/106 (97.2%) and 105/106 (99.1%), respectively. The ODS under investigation was suitable for oestrus detection in dairy cows on pasture and showed a high sensitivity of oestrus detection. Multimetric analysis of behavioural data seems to be the superior approach to developing and improving ODS for dairy cows on pasture. Due to a high proportion of false positive alerts, its use as a stand-alone system for oestrus detection cannot be recommended. As it is the first time the system was investigated, testing on other farms would be necessary for further validation.
Wickens, Christopher; Colcombe, Angela
2007-10-01
Performance consequences related to integrating an imperfect alert within a complex task domain were examined in two experiments. Cockpit displays of traffic information (CDTIs) are being designed for use in airplane cockpits as responsibility for safe separation becomes shared between pilots and controllers. Of interest in this work is how characteristics of the alarm system such as threshold, modality, and number of alert levels impact concurrent task (flight control) performance and response to potential conflicts. Student pilots performed a tracking task analogous to flight control while simultaneously monitoring for air traffic conflicts with the aid of a CDTI alert as the threshold, modality, and level of alert was varied. As the alerting system became more prone to false alerts, pilot compliance decreased and concurrent performance improved. There was some evidence of auditory preemption with auditory alerts as the false alarm rate increased. Finally, there was no benefit to a three-level system over a two-level system. There is justification for increased false alarm rates, as miss-prone systems appear to be costly. The 4:1 false alarm to miss ratio employed here improved accuracy and concurrent task performance. More research needs to address the potential benefits of likelihood alerting. The issues addressed in this research can be applied to any imperfect alerting system such as in aviation, driving, or air traffic control. It is crucial to understand the performance consequences of new technology and the efficacy of potential mitigating design features within the specific context desired.
Makam, Anil N.; Nguyen, Oanh K.; Auerbach, Andrew D.
2015-01-01
Background Although timely treatment of sepsis improves outcomes, delays in administering evidence-based therapies are common. Purpose To determine whether automated real-time electronic sepsis alerts can: 1) accurately identify sepsis, and 2) improve process measures and outcomes. Data Sources We systematically searched MEDLINE, Embase, The Cochrane Library, and CINAHL from database inception through June 27, 2014. Study Selection Included studies that empirically evaluated one or both of the prespecified objectives. Data Extraction Two independent reviewers extracted data and assessed the risk of bias. Diagnostic accuracy of sepsis identification was measured by sensitivity, specificity, positive (PPV) and negative predictive values (NPV) and likelihood ratios (LR). Effectiveness was assessed by changes in sepsis care process measures and outcomes. Data Synthesis Of 1,293 citations, 8 studies met inclusion criteria, 5 for the identification of sepsis (n=35,423) and 5 for the effectiveness of sepsis alerts (n=6,894). Though definition of sepsis alert thresholds varied, most included systemic inflammatory response syndrome criteria ± evidence of shock. Diagnostic accuracy varied greatly, with PPV ranging from 20.5-53.8%, NPV 76.5-99.7%; LR+ 1.2-145.8; and LR- 0.06-0.86. There was modest evidence for improvement in process measures (i.e., antibiotic escalation), but only among patients in non-critical care settings; there were no corresponding improvements in mortality or length of stay. Minimal data were reported on potential harms due to false positive alerts. Conclusions Automated sepsis alerts derived from electronic health data may improve care processes but tend to have poor positive predictive value and do not improve mortality or length of stay. PMID:25758641
Radhakrishna, K.; Bowles, K.; Zettek-Sumner, A.
2013-01-01
Summary Background Telehealth data overload through high alert generation is a significant barrier to sustained adoption of telehealth for managing HF patients. Objective To explore the factors contributing to frequent telehealth alerts including false alerts for Medicare heart failure (HF) patients admitted to a home health agency. Materials and Methods A mixed methods design that combined quantitative correlation analysis of patient characteristic data with number of telehealth alerts and qualitative analysis of telehealth and visiting nurses’ notes on follow-up actions to patients’ telehealth alerts was employed. All the quantitative and qualitative data was collected through retrospective review of electronic records of the home heath agency. Results Subjects in the study had a mean age of 83 (SD = 7.6); 56% were female. Patient co-morbidities (p<0.05) of renal disorders, anxiety, and cardiac arrhythmias emerged as predictors of telehealth alerts through quantitative analysis (n = 168) using multiple regression. Inappropriate telehealth measurement technique by patients (54%) and home healthcare system inefficiencies (37%) contributed to most telehealth false alerts in the purposive qualitative sub-sample (n = 35) of patients with high telehealth alerts. Conclusion Encouraging patient engagement with the telehealth process, fostering a collaborative approach among all the clinicians involved with the telehealth intervention, tailoring telehealth alert thresholds to patient characteristics along with establishing patient-centered telehealth outcome goals may allow meaningful generation of telehealth alerts. Reducing avoidable telehealth alerts could vastly improve the efficiency and sustainability of telehealth programs for HF management. PMID:24454576
Reliability of Trained Dogs to Alert to Hypoglycemia in Patients With Type 1 Diabetes
Los, Evan A.; Ramsey, Katrina L.; Guttmann-Bauman, Ines; Ahmann, Andrew J.
2016-01-01
Background: We examined the reliability of trained dogs to alert to hypoglycemia in individuals with type 1 diabetes. Methods: Patients with type 1 diabetes who currently used diabetes alert dogs participated in this exploratory study. Subjects reported satisfaction, perceived dog glucose sensing ability and reasons for obtaining a trained dog. Reliability of dog alerts was assessed using capillary blood glucose (CBG) and blinded continuous glucose monitoring (CGM) as comparators in 8 subjects (age 4-48). Hypoglycemia was defined as CBG or CGM <70 mg/dL. Results: Dog users were very satisfied (8.9/10 on a Likert-type scale) and largely confident (7.9/10) in their dog’s ability to detect hypoglycemia. Detection of hypoglycemia was the primary reason for obtaining a trained dog. During hypoglycemia, spontaneous dog alerts occurred at a rate 3.2 (2.0-5.2, 95% CI) times higher than during euglycemia (70-179 mg/dL). Dogs provided timely alerts in 36% (sensitivity) of all hypoglycemia events (n = 45). Due to inappropriate alerts, the PPV of a dog alert for hypoglycemia was 12%. When there was concurrence of a hypoglycemic event between the dog alert and CGM (n = 30), CGM would have alerted prior to the dog in 73% of events (median 22-minute difference). Conclusions: This is the first study evaluating reliability of trained dogs to alert to hypoglycemia under real-life conditions. Trained dogs often alert a human companion to otherwise unknown hypoglycemia; however due to high false-positive rate, a dog alert alone is unlikely to be helpful in differentiating hypo-/hyper-/euglycemia. CGM often detects hypoglycemia before a trained dog by a clinically significant margin. PMID:27573791
Reliability of Trained Dogs to Alert to Hypoglycemia in Patients With Type 1 Diabetes.
Los, Evan A; Ramsey, Katrina L; Guttmann-Bauman, Ines; Ahmann, Andrew J
2017-05-01
We examined the reliability of trained dogs to alert to hypoglycemia in individuals with type 1 diabetes. Patients with type 1 diabetes who currently used diabetes alert dogs participated in this exploratory study. Subjects reported satisfaction, perceived dog glucose sensing ability and reasons for obtaining a trained dog. Reliability of dog alerts was assessed using capillary blood glucose (CBG) and blinded continuous glucose monitoring (CGM) as comparators in 8 subjects (age 4-48). Hypoglycemia was defined as CBG or CGM <70 mg/dL. Dog users were very satisfied (8.9/10 on a Likert-type scale) and largely confident (7.9/10) in their dog's ability to detect hypoglycemia. Detection of hypoglycemia was the primary reason for obtaining a trained dog. During hypoglycemia, spontaneous dog alerts occurred at a rate 3.2 (2.0-5.2, 95% CI) times higher than during euglycemia (70-179 mg/dL). Dogs provided timely alerts in 36% (sensitivity) of all hypoglycemia events (n = 45). Due to inappropriate alerts, the PPV of a dog alert for hypoglycemia was 12%. When there was concurrence of a hypoglycemic event between the dog alert and CGM (n = 30), CGM would have alerted prior to the dog in 73% of events (median 22-minute difference). This is the first study evaluating reliability of trained dogs to alert to hypoglycemia under real-life conditions. Trained dogs often alert a human companion to otherwise unknown hypoglycemia; however due to high false-positive rate, a dog alert alone is unlikely to be helpful in differentiating hypo-/hyper-/euglycemia. CGM often detects hypoglycemia before a trained dog by a clinically significant margin.
47 CFR 10.300 - Alert aggregator. [Reserved
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.300 Alert aggregator. [Reserved] ...
47 CFR 10.300 - Alert aggregator. [Reserved
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.300 Alert aggregator. [Reserved] ...
47 CFR 10.300 - Alert aggregator. [Reserved
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...
47 CFR 10.300 - Alert aggregator. [Reserved
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...
47 CFR 10.300 - Alert aggregator. [Reserved
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...
Improving the Quality of Alerts and Predicting Intruder's Next Goal with Hidden Colored Petri-Net
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Dong; Frincke, Deb A.
2006-06-22
Intrusion detection systems (IDS) often provide poor quality alerts, which are insufficient to support rapid identification of ongoing attacks or predict an intruder’s next likely goal. In this paper, we propose a novel approach to alert post-processing and correlation, the Hidden Colored Petri-Net (HCPN). Different from most other alert correlation methods, our approach treats the alert correlation problem as an inference problem rather than a filter problem. Our approach assumes that the intruder’s actions are unknown to the IDS and can be inferred only from the alerts generated by the IDS sensors. HCPN can describe the relationship between different stepsmore » carried out by intruders, model observations (alerts) and transitions (actions) separately, and associate each token element (system state) with a probability (or confidence). The model is an extension to Colored Petri-Net (CPN) .It is so called “hidden” because the transitions (actions) are not directly observable but can be inferred by looking through the observations (alerts). These features make HCPN especially suitable for discovering intruders’ actions from their partial observations (alerts,) and predicting intruders’ next goal. Our experiments on DARPA evaluation datasets and the attack scenarios from the Grand Challenge Problem (GCP) show that HCPN has promise as a way to reducing false positives and negatives, predicting intruder’s next possible action, uncovering intruders’ intrusion strategies after the attack scenario has happened, and providing confidence scores.« less
47 CFR 10.310 - Federal alert gateway. [Reserved
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...
47 CFR 10.310 - Federal alert gateway. [Reserved
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.310 Federal alert gateway. [Reserved] ...
47 CFR 10.310 - Federal alert gateway. [Reserved
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.310 Federal alert gateway. [Reserved] ...
47 CFR 10.310 - Federal alert gateway. [Reserved
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...
47 CFR 10.310 - Federal alert gateway. [Reserved
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...
Tactical Conflict Detection in Terminal Airspace
NASA Technical Reports Server (NTRS)
Tang, Huabin; Robinson, John E.; Denery, Dallas G.
2010-01-01
Air traffic systems have long relied on automated short-term conflict prediction algorithms to warn controllers of impending conflicts (losses of separation). The complexity of terminal airspace has proven difficult for such systems as it often leads to excessive false alerts. Thus, the legacy system, called Conflict Alert, which provides short-term alerts in both en-route and terminal airspace currently, is often inhibited or degraded in areas where frequent false alerts occur, even though the alerts are provided only when an aircraft is in dangerous proximity of other aircraft. This research investigates how a minimal level of flight intent information may be used to improve short-term conflict detection in terminal airspace such that it can be used by the controller to maintain legal aircraft separation. The flight intent information includes a site-specific nominal arrival route and inferred altitude clearances in addition to the flight plan that includes the RNAV (Area Navigation) departure route. A new tactical conflict detection algorithm is proposed, which uses a single analytic trajectory, determined by the flight intent and the current state information of the aircraft, and includes a complex set of current, dynamic separation standards for terminal airspace to define losses of separation. The new algorithm is compared with an algorithm that imitates a known en-route algorithm and another that imitates Conflict Alert by analysis of false-alert rate and alert lead time with recent real-world data of arrival and departure operations and a large set of operational error cases from Dallas/Fort Worth TRACON (Terminal Radar Approach Control). The new algorithm yielded a false-alert rate of two per hour and an average alert lead time of 38 seconds.
47 CFR 80.1114 - False distress alerts.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false False distress alerts. 80.1114 Section 80.1114 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating Procedures for Distress and...
47 CFR 80.1114 - False distress alerts.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false False distress alerts. 80.1114 Section 80.1114 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating Procedures for Distress and...
Lessons from Hawaii: A Blessing in Disguise.
Deitchman, Scott; Dallas, Cham E; Burkle, Frederick
2018-03-20
On January 13, 2018, Hawaii experienced an erroneous alert that falsely warned of an imminent ballistic missile strike. Rather than focus on the inconvenience caused by the false alert, we used reporting of the event to identify the missing elements that would characterize a system that could save lives by alerting and informing the public in a nuclear detonation. These include warnings that contain essential information rather than directing recipients to secondary sources; a system that issues alerts directly from federal agencies that will have the earliest warning; a robust multimodal alerting system that can deliver messages before and after the detonation; and swift activation of federal agencies immediately upon warning.
47 CFR 10.320 - Provider alert gateway requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...
47 CFR 10.320 - Provider alert gateway requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...
47 CFR 10.410 - Prioritization.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Prioritization. 10.410 Section 10.410 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message... required to transmit Imminent Threat Alerts and AMBER Alerts on a first in-first out (FIFO) basis. ...
Developing the surveillance algorithm for detection of failure to recognize and treat severe sepsis.
Harrison, Andrew M; Thongprayoon, Charat; Kashyap, Rahul; Chute, Christopher G; Gajic, Ognjen; Pickering, Brian W; Herasevich, Vitaly
2015-02-01
To develop and test an automated surveillance algorithm (sepsis "sniffer") for the detection of severe sepsis and monitoring failure to recognize and treat severe sepsis in a timely manner. We conducted an observational diagnostic performance study using independent derivation and validation cohorts from an electronic medical record database of the medical intensive care unit (ICU) of a tertiary referral center. All patients aged 18 years and older who were admitted to the medical ICU from January 1 through March 31, 2013 (N=587), were included. The criterion standard for severe sepsis/septic shock was manual review by 2 trained reviewers with a third superreviewer for cases of interobserver disagreement. Critical appraisal of false-positive and false-negative alerts, along with recursive data partitioning, was performed for algorithm optimization. An algorithm based on criteria for suspicion of infection, systemic inflammatory response syndrome, organ hypoperfusion and dysfunction, and shock had a sensitivity of 80% and a specificity of 96% when applied to the validation cohort. In order, low systolic blood pressure, systemic inflammatory response syndrome positivity, and suspicion of infection were determined through recursive data partitioning to be of greatest predictive value. Lastly, 117 alert-positive patients (68% of the 171 patients with severe sepsis) had a delay in recognition and treatment, defined as no lactate and central venous pressure measurement within 2 hours of the alert. The optimized sniffer accurately identified patients with severe sepsis that bedside clinicians failed to recognize and treat in a timely manner. Copyright © 2015 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
16 CFR 613.1 - Duration of active duty alerts.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...
16 CFR 613.1 - Duration of active duty alerts.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...
16 CFR 613.1 - Duration of active duty alerts.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...
47 CFR 80.277 - Ship Security Alert System (SSAS).
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Ship Security Alert System (SSAS). 80.277... Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety..., “RTCM Standard 11020.0—Ship Security Alert Systems (SSAS) using the Cospas-Sarsat System,” Version 1.0...
47 CFR 10.320 - Provider alert gateway requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...
Clinical decision support alert malfunctions: analysis and empirically derived taxonomy.
Wright, Adam; Ai, Angela; Ash, Joan; Wiesen, Jane F; Hickman, Thu-Trang T; Aaron, Skye; McEvoy, Dustin; Borkowsky, Shane; Dissanayake, Pavithra I; Embi, Peter; Galanter, William; Harper, Jeremy; Kassakian, Steve Z; Ramoni, Rachel; Schreiber, Richard; Sirajuddin, Anwar; Bates, David W; Sittig, Dean F
2018-05-01
To develop an empirically derived taxonomy of clinical decision support (CDS) alert malfunctions. We identified CDS alert malfunctions using a mix of qualitative and quantitative methods: (1) site visits with interviews of chief medical informatics officers, CDS developers, clinical leaders, and CDS end users; (2) surveys of chief medical informatics officers; (3) analysis of CDS firing rates; and (4) analysis of CDS overrides. We used a multi-round, manual, iterative card sort to develop a multi-axial, empirically derived taxonomy of CDS malfunctions. We analyzed 68 CDS alert malfunction cases from 14 sites across the United States with diverse electronic health record systems. Four primary axes emerged: the cause of the malfunction, its mode of discovery, when it began, and how it affected rule firing. Build errors, conceptualization errors, and the introduction of new concepts or terms were the most frequent causes. User reports were the predominant mode of discovery. Many malfunctions within our database caused rules to fire for patients for whom they should not have (false positives), but the reverse (false negatives) was also common. Across organizations and electronic health record systems, similar malfunction patterns recurred. Challenges included updates to code sets and values, software issues at the time of system upgrades, difficulties with migration of CDS content between computing environments, and the challenge of correctly conceptualizing and building CDS. CDS alert malfunctions are frequent. The empirically derived taxonomy formalizes the common recurring issues that cause these malfunctions, helping CDS developers anticipate and prevent CDS malfunctions before they occur or detect and resolve them expediently.
12 CFR 1022.121 - Active duty alerts.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 12 Banks and Banking 8 2014-01-01 2014-01-01 false Active duty alerts. 1022.121 Section 1022.121... Consumer Reporting Agencies Regarding Identity Theft § 1022.121 Active duty alerts. (a) Duration. The duration of an active duty alert shall be twelve months. ...
12 CFR 1022.121 - Active duty alerts.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 12 Banks and Banking 8 2013-01-01 2013-01-01 false Active duty alerts. 1022.121 Section 1022.121... Consumer Reporting Agencies Regarding Identity Theft § 1022.121 Active duty alerts. (a) Duration. The duration of an active duty alert shall be twelve months. ...
12 CFR 1022.121 - Active duty alerts.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 12 Banks and Banking 8 2012-01-01 2012-01-01 false Active duty alerts. 1022.121 Section 1022.121... Consumer Reporting Agencies Regarding Identity Theft § 1022.121 Active duty alerts. (a) Duration. The duration of an active duty alert shall be twelve months. (b) [Reserved] ...
Makam, Anil N; Nguyen, Oanh K; Auerbach, Andrew D
2015-06-01
Although timely treatment of sepsis improves outcomes, delays in administering evidence-based therapies are common. To determine whether automated real-time electronic sepsis alerts can: (1) accurately identify sepsis and (2) improve process measures and outcomes. We systematically searched MEDLINE, Embase, The Cochrane Library, and Cumulative Index to Nursing and Allied Health Literature from database inception through June 27, 2014. Included studies that empirically evaluated 1 or both of the prespecified objectives. Two independent reviewers extracted data and assessed the risk of bias. Diagnostic accuracy of sepsis identification was measured by sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and likelihood ratio (LR). Effectiveness was assessed by changes in sepsis care process measures and outcomes. Of 1293 citations, 8 studies met inclusion criteria, 5 for the identification of sepsis (n = 35,423) and 5 for the effectiveness of sepsis alerts (n = 6894). Though definition of sepsis alert thresholds varied, most included systemic inflammatory response syndrome criteria ± evidence of shock. Diagnostic accuracy varied greatly, with PPV ranging from 20.5% to 53.8%, NPV 76.5% to 99.7%, LR+ 1.2 to 145.8, and LR- 0.06 to 0.86. There was modest evidence for improvement in process measures (ie, antibiotic escalation), but only among patients in non-critical care settings; there were no corresponding improvements in mortality or length of stay. Minimal data were reported on potential harms due to false positive alerts. Automated sepsis alerts derived from electronic health data may improve care processes but tend to have poor PPV and do not improve mortality or length of stay. © 2015 Society of Hospital Medicine.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Alert system. 26.20 Section 26.20 Food and Drugs... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an alert...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Alert system. 26.20 Section 26.20 Food and Drugs... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an alert...
47 CFR 11.56 - EAS Participants receive CAP-formatted alerts.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false EAS Participants receive CAP-formatted alerts... SYSTEM (EAS) Emergency Operations § 11.56 EAS Participants receive CAP-formatted alerts. Notwithstanding anything herein to the contrary, all EAS Participants must be able to receive CAP-formatted EAS alerts no...
Code of Federal Regulations, 2010 CFR
2010-04-01
... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Alert system. 26.20 Section 26.20 Food and Drugs... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an alert...
47 CFR 80.277 - Ship Security Alert System (SSAS).
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...
47 CFR 80.277 - Ship Security Alert System (SSAS).
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...
47 CFR 80.277 - Ship Security Alert System (SSAS).
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...
47 CFR 80.277 - Ship Security Alert System (SSAS).
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...
47 CFR 10.410 - Prioritization.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Prioritization. 10.410 Section 10.410 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.410 Prioritization. A Participating CMS Provider is required to transmit Presidential Alerts...
47 CFR 80.335 - Procedures for canceling false distress alerts.
Code of Federal Regulations, 2014 CFR
2014-10-01
... priority message by way of the same land earth station through which the false distress alert was sent.... 80.335 Section 80.335 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress...
47 CFR 80.335 - Procedures for canceling false distress alerts.
Code of Federal Regulations, 2013 CFR
2013-10-01
... priority message by way of the same land earth station through which the false distress alert was sent.... 80.335 Section 80.335 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress...
47 CFR 80.335 - Procedures for canceling false distress alerts.
Code of Federal Regulations, 2010 CFR
2010-10-01
... priority message by way of the same land earth station through which the false distress alert was sent.... 80.335 Section 80.335 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress...
47 CFR 80.335 - Procedures for canceling false distress alerts.
Code of Federal Regulations, 2012 CFR
2012-10-01
... priority message by way of the same land earth station through which the false distress alert was sent.... 80.335 Section 80.335 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress...
47 CFR 80.335 - Procedures for canceling false distress alerts.
Code of Federal Regulations, 2011 CFR
2011-10-01
... priority message by way of the same land earth station through which the false distress alert was sent.... 80.335 Section 80.335 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress...
47 CFR 10.440 - Embedded reference prohibition.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.440 Embedded reference prohibition. A CMAS Alert Message processed by a...
47 CFR 10.320 - Provider alert gateway requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM... that each Participating Commercial Mobile Service provider is required to support and perform at its...
47 CFR 10.420 - Message elements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Message elements. 10.420 Section 10.420 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.420 Message elements. A CMAS Alert Message processed by a Participating CMS Provider shall...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Definitions. 10.10 Section 10.10 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM General Information § 10.10 Definitions. (a) Alert Message. An Alert Message is a message that is intended to provide the...
47 CFR 10.440 - Embedded reference prohibition.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.440 Embedded reference prohibition. A CMAS Alert Message processed by a...
47 CFR 10.440 - Embedded reference prohibition.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.440 Embedded reference prohibition. A CMAS Alert Message processed by a...
47 CFR 10.430 - Character limit.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Character limit. 10.430 Section 10.430 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.430 Character limit. A CMAS Alert Message processed by a Participating CMS Provider must not...
Clinically relevant hypoglycemia prediction metrics for event mitigation.
Harvey, Rebecca A; Dassau, Eyal; Zisser, Howard C; Bevier, Wendy; Seborg, Dale E; Jovanovič, Lois; Doyle, Francis J
2012-08-01
The purpose of this study was to develop a method to compare hypoglycemia prediction algorithms and choose parameter settings for different applications, such as triggering insulin pump suspension or alerting for rescue carbohydrate treatment. Hypoglycemia prediction algorithms with different parameter settings were implemented on an ambulatory dataset containing 490 days from 30 subjects with type 1 diabetes mellitus using the Dexcom™ (San Diego, CA) SEVEN™ continuous glucose monitoring system. The performance was evaluated using a proposed set of metrics representing the true-positive ratio, false-positive rate, and distribution of warning times. A prospective, in silico study was performed to show the effect of using different parameter settings to prevent or rescue from hypoglycemia. The retrospective study results suggest the parameter settings for different methods of hypoglycemia mitigation. When rescue carbohydrates are used, a high true-positive ratio, a minimal false-positive rate, and alarms with short warning time are desired. These objectives were met with a 30-min prediction horizon and two successive flags required to alarm: 78% of events were detected with 3.0 false alarms/day and 66% probability of alarms occurring within 30 min of the event. This parameter setting selection was confirmed in silico: treating with rescue carbohydrates reduced the duration of hypoglycemia from 14.9% to 0.5%. However, for a different method, such as pump suspension, this parameter setting only reduced hypoglycemia to 8.7%, as can be expected by the low probability of alarming more than 30 min ahead. The proposed metrics allow direct comparison of hypoglycemia prediction algorithms and selection of parameter settings for different types of hypoglycemia mitigation, as shown in the prospective in silico study in which hypoglycemia was alerted or treated with rescue carbohydrates.
77 FR 8181 - Airworthiness Directives; Fokker Services B.V. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-14
... hydraulic system and accompanying alerts for ``hydraulic system 1 low quantity'' and ``hydraulic system 2... of the hydraulic system and accompanying alerts for ``hydraulic system 1 low quantity'' and... for these alerts may give the false impression that the stabiliser is still hydraulically controllable...
Benjamin, Richard J; McDonald, Carl P
2014-04-01
The BacT/ALERT microbial detection system (bioMerieux, Inc, Durham, NC) is in routine use in many blood centers as a prerelease test for platelet collections. Published reports document wide variation in practices and outcomes. A systematic review of the English literature was performed to describe publications assessing the use of the BacT/ALERT culture system on platelet collections as a routine screen test of more than 10000 platelet components. Sixteen publications report the use of confirmatory testing to substantiate initial positive culture results but use varying nomenclature to classify the results. Preanalytical and analytical variables that may affect the outcomes differ widely between centers. Incomplete description of protocol details complicates comparison between sites. Initial positive culture results range from 539 to 10606 per million (0.054%-1.061%) and confirmed positive from 127 to 1035 per million (0.013%-0.104%) donations. False-negative results determined by outdate culture range from 662 to 2173 per million (0.066%-0.217%) and by septic reactions from 0 to 66 per million (0%-0.007%) collections. Current culture protocols represent pragmatic compromises between optimizing analytical sensitivity and ensuring the timely availability of platelets for clinical needs. Insights into the effect of protocol variations on outcomes are generally restricted to individual sites that implement limited changes to their protocols over time. Platelet manufacturers should reassess the adequacy of their BacT/ALERT screening protocols in light of the growing international experience and provide detailed documentation of all variables that may affect culture outcomes when reporting results. We propose a framework for a standardized nomenclature for reporting of the results of BacT/ALERT screening. Copyright © 2014 Elsevier Inc. All rights reserved.
Human Factors Evaluation of Conflict Detection Tool for Terminal Area
NASA Technical Reports Server (NTRS)
Verma, Savita Arora; Tang, Huabin; Ballinger, Deborah; Chinn, Fay Cherie; Kozon, Thomas E.
2013-01-01
A conflict detection and resolution tool, Terminal-area Tactical Separation-Assured Flight Environment (T-TSAFE), is being developed to improve the timeliness and accuracy of alerts and reduce the false alert rate observed with the currently deployed technology. The legacy system in use today, Conflict Alert, relies primarily on a dead reckoning algorithm, whereas T-TSAFE uses intent information to augment dead reckoning. In previous experiments, T-TSAFE was found to reduce the rate of false alerts and increase time between the alert to the controller and a loss of separation over the legacy system. In the present study, T-TSAFE was tested under two meteorological conditions, 1) all aircraft operated under instrument flight regimen, and 2) some aircraft operated under mixed operating conditions. The tool was used to visually alert controllers to predicted Losses of separation throughout the terminal airspace, and show compression errors, on final approach. The performance of T-TSAFE on final approach was compared with Automated Terminal Proximity Alert (ATPA), a tool recently deployed by the FAA. Results show that controllers did not report differences in workload or situational awareness between the T-TSAFE and ATPA cones but did prefer T-TSAFE features over ATPA functionality. T-TSAFE will provide one tool that shows alerts in the data blocks and compression errors via cones on the final approach, implementing all tactical conflict detection and alerting via one tool in TRACON airspace.
21 CFR 26.50 - Alert system and exchange of postmarket vigilance reports.
Code of Federal Regulations, 2010 CFR
2010-04-01
... QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN MEDICAL DEVICE PRODUCT EVALUATION REPORTS: UNITED STATES AND THE EUROPEAN COMMUNITY Specific Sector Provisions for Medical Devices § 26.50 Alert system and exchange of... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Alert system and exchange of postmarket vigilance...
47 CFR 76.1711 - Emergency alert system (EAS) tests and activation.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 4 2012-10-01 2012-10-01 false Emergency alert system (EAS) tests and activation. 76.1711 Section 76.1711 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Documents to be Maintained for Inspection § 76.1711 Emergency alert system (EAS)...
47 CFR 76.1711 - Emergency alert system (EAS) tests and activation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 4 2014-10-01 2014-10-01 false Emergency alert system (EAS) tests and activation. 76.1711 Section 76.1711 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Documents to be Maintained for Inspection § 76.1711 Emergency alert system (EAS)...
Balamuth, Fran; Alpern, Elizabeth R; Abbadessa, Mary Kate; Hayes, Katie; Schast, Aileen; Lavelle, Jane; Fitzgerald, Julie C; Weiss, Scott L; Zorc, Joseph J
2017-12-01
Recognition of pediatric sepsis is a key clinical challenge. We evaluate the performance of a sepsis recognition process including an electronic sepsis alert and bedside assessment in a pediatric emergency department (ED). This was a cohort study with quality improvement intervention in a pediatric ED. Exposure was a positive electronic sepsis alert, defined as elevated pulse rate or hypotension, concern for infection, and at least one of the following: abnormal capillary refill, abnormal mental status, or high-risk condition. A positive electronic sepsis alert prompted team assessment or huddle to determine need for sepsis protocol. Clinicians could initiate team assessment or huddle according to clinical concern without positive electronic sepsis alert. Severe sepsis outcome defined as activation of the sepsis protocol in the ED or development of severe sepsis requiring ICU admission within 24 hours. There were 182,509 ED visits during the study period, with 86,037 before electronic sepsis alert implementation and 96,472 afterward, and 1,112 (1.2%) positive electronic sepsis alerts. Overall, 326 patients (0.3%) were treated for severe sepsis within 24 hours. Test characteristics of the electronic sepsis alert alone to detect severe sepsis were sensitivity 86.2% (95% confidence interval [CI] 82.0% to 89.5%), specificity 99.1% (95% CI 99.0% to 99.2%), positive predictive value 25.4% (95% CI 22.8% to 28.0%), and negative predictive value 100% (95% CI 99.9% to 100%). Inclusion of the clinician screen identified 43 additional electronic sepsis alert-negative children, with severe sepsis sensitivity 99.4% (95% CI 97.8% to 99.8%) and specificity 99.1% (95% CI 99.1% to 99.2%). Electronic sepsis alert implementation increased ED sepsis detection from 83% to 96%. Electronic sepsis alert for severe sepsis demonstrated good sensitivity and high specificity. Addition of clinician identification of electronic sepsis alert-negative patients further improved sensitivity. Implementation of the electronic sepsis alert was associated with improved recognition of severe sepsis. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Perils of using speed zone data to assess real-world compliance to speed limits.
Chevalier, Anna; Clarke, Elizabeth; Chevalier, Aran John; Brown, Julie; Coxon, Kristy; Ivers, Rebecca; Keay, Lisa
2017-11-17
Real-world driving studies, including those involving speeding alert devices and autonomous vehicles, can gauge an individual vehicle's speeding behavior by comparing measured speed with mapped speed zone data. However, there are complexities with developing and maintaining a database of mapped speed zones over a large geographic area that may lead to inaccuracies within the data set. When this approach is applied to large-scale real-world driving data or speeding alert device data to determine speeding behavior, these inaccuracies may result in invalid identification of speeding. We investigated speeding events based on service provider speed zone data. We compared service provider speed zone data (Speed Alert by Smart Car Technologies Pty Ltd., Ultimo, NSW, Australia) against a second set of speed zone data (Google Maps Application Programming Interface [API] mapped speed zones). We found a systematic error in the zones where speed limits of 50-60 km/h, typical of local roads, were allocated to high-speed motorways, which produced false speed limits in the speed zone database. The result was detection of false-positive high-range speeding. Through comparison of the service provider speed zone data against a second set of speed zone data, we were able to identify and eliminate data most affected by this systematic error, thereby establishing a data set of speeding events with a high level of sensitivity (a true positive rate of 92% or 6,412/6,960). Mapped speed zones can be a source of error in real-world driving when examining vehicle speed. We explored the types of inaccuracies found within speed zone data and recommend that a second set of speed zone data be utilized when investigating speeding behavior or developing mapped speed zone data to minimize inaccuracy in estimates of speeding.
21 CFR 26.50 - Alert system and exchange of postmarket vigilance reports.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Alert system and exchange of postmarket vigilance reports. 26.50 Section 26.50 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... postmarket vigilance reports. (a) An alert system will be set up during the transition period and maintained...
Alerts of forest disturbance from MODIS imagery
NASA Astrophysics Data System (ADS)
Hammer, Dan; Kraft, Robin; Wheeler, David
2014-12-01
This paper reports the methodology and computational strategy for a forest cover disturbance alerting system. Analytical techniques from time series econometrics are applied to imagery from the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor to detect temporal instability in vegetation indices. The characteristics from each MODIS pixel's spectral history are extracted and compared against historical data on forest cover loss to develop a geographically localized classification rule that can be applied across the humid tropical biome. The final output is a probability of forest disturbance for each 500 m pixel that is updated every 16 days. The primary objective is to provide high-confidence alerts of forest disturbance, while minimizing false positives. We find that the alerts serve this purpose exceedingly well in Pará, Brazil, with high probability alerts garnering a user accuracy of 98 percent over the training period and 93 percent after the training period (2000-2005) when compared against the PRODES deforestation data set, which is used to assess spatial accuracy. Implemented in Clojure and Java on the Hadoop distributed data processing platform, the algorithm is a fast, automated, and open source system for detecting forest disturbance. It is intended to be used in conjunction with higher-resolution imagery and data products that cannot be updated as quickly as MODIS-based data products. By highlighting hotspots of change, the algorithm and associated output can focus high-resolution data acquisition and aid in efforts to enforce local forest conservation efforts.
47 CFR 10.460 - Retransmission frequency. [Reserved
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Retransmission frequency. [Reserved] 10.460 Section 10.460 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.460 Retransmission frequency. [Reserved] ...
10. DETAIL OF NUCLEAR ALERT INSIGNIA, EAST WALL NORTHWEST OFFICE ...
10. DETAIL OF NUCLEAR ALERT INSIGNIA, EAST WALL NORTHWEST OFFICE ABOVE FORMER FALSE CEILING - Selfridge Field, Building Nos. 1424, 1425, South of Carswell Street, west of Castle Avenue, Mount Clemens, Macomb County, MI
ElarmS Earthquake Early Warning System: 2017 Performance and New ElarmS Version 3.0 (E3)
NASA Astrophysics Data System (ADS)
Chung, A. I.; Henson, I. H.; Allen, R. M.; Hellweg, M.; Neuhauser, D. S.
2017-12-01
The ElarmS earthquake early warning (EEW) system has been successfully detecting earthquakes throughout California since 2007. ElarmS version 2.0 (E2) is one of the three algorithms contributing alerts to ShakeAlert, a public EEW system being developed by the USGS in collaboration with UC Berkeley, Caltech, University of Washington, and University of Oregon. E2 began operating in test mode in the Pacific Northwest in 2013, and since April of this year E2 has been contributing real-time alerts from Oregon and Washington to the ShakeAlert production prototype system as part of the ShakeAlert roll-out throughout the West Coast. Since it began operating west-coast-wide, E2 has correctly alerted on 5 events that matched ANSS catalog events with M≥4, missed 1 event with M≥4, and incorrectly created alerts for 5 false events with M≥4. The most recent version of the algorithm, ElarmS version 3.0 (E3), is a significant improvement over E2. It addresses some of the most problematic causes of false events for which E2 produced alerts, without impacting reliability in terms of matched and missed events. Of the 5 false events that were generated by E2 since April, 4 would have been suppressed by E3. In E3, we have added a filterbank teleseismic filter. By analyzing the amplitude of the waveform filtered in various passbands, it is possible to distinguish between local and teleseismic events. We have also added a series of checks to validate triggers and filter out spurious and S-wave triggers. Additional improvements to the waveform associator also improve detections. In this presentation, we describe the improvements and compare the performance of the current production (E2) and development (E3) versions of ElarmS over the past year. The ShakeAlert project is now working through a streamlining process to identify the best components of various algorithms and merge them. The ElarmS team is participating in this effort and we anticipate that much of E3 will continue in the final system.
Terminal - Tactical Separation Assured Flight Environment (T-TSafe)
NASA Technical Reports Server (NTRS)
Verma, Savita Arora; Tang, Huabin; Ballinger, Debbi
2011-01-01
The Tactical Separation Assured Flight Environment (TSAFE) has been previously tested as a conflict detection and resolution tool in the en-route phase of flight. Fast time simulations of a terminal version of this tool called Terminal TSAFE (T-TSAFE) have shown promise over the current conflict detection tools. It has shown to have fewer false alerts (as low as 2 per hour) and better prediction to conflict time than Conflict Alert. The tool will be tested in the simulated terminal area of Los Angeles International Airport, in a Human-in-the-loop experiment to identify controller procedures and information requirements. The simulation will include comparisons of T-TSAFE with NASA's version of Conflict Alert. Also, some other variables such as altitude entry by the controller, which improve T-TSAFE's predictions for conflict detection, will be tested. T-TSAFE integrates features of current conflict detection tools such as Automated Terminal Proximity Alert used to alleviate compression errors in the final approach phase. Based on fast-time simulation analysis, the anticipated benefits of T-TSAFE over Conflict Alert include reduced false/missed alerts and increased time to predicted loss of separation. Other metrics that will be used to evaluate the tool's impact on the controller include controller intervention, workload, and situation awareness.
Tracking Object Existence From an Autonomous Patrol Vehicle
NASA Technical Reports Server (NTRS)
Wolf, Michael; Scharenbroich, Lucas
2011-01-01
An autonomous vehicle patrols a large region, during which an algorithm receives measurements of detected potential objects within its sensor range. The goal of the algorithm is to track all objects in the region over time. This problem differs from traditional multi-target tracking scenarios because the region of interest is much larger than the sensor range and relies on the movement of the sensor through this region for coverage. The goal is to know whether anything has changed between visits to the same location. In particular, two kinds of alert conditions must be detected: (1) a previously detected object has disappeared and (2) a new object has appeared in a location already checked. For the time an object is within sensor range, the object can be assumed to remain stationary, changing position only between visits. The problem is difficult because the upstream object detection processing is likely to make many errors, resulting in heavy clutter (false positives) and missed detections (false negatives), and because only noisy, bearings-only measurements are available. This work has three main goals: (1) Associate incoming measurements with known objects or mark them as new objects or false positives, as appropriate. For this, a multiple hypothesis tracker was adapted to this scenario. (2) Localize the objects using multiple bearings-only measurements to provide estimates of global position (e.g., latitude and longitude). A nonlinear Kalman filter extension provides these 2D position estimates using the 1D measurements. (3) Calculate the probability that a suspected object truly exists (in the estimated position), and determine whether alert conditions have been triggered (for new objects or disappeared objects). The concept of a probability of existence was created, and a new Bayesian method for updating this probability at each time step was developed. A probabilistic multiple hypothesis approach is chosen because of its superiority in handling the uncertainty arising from errors in sensors and upstream processes. However, traditional target tracking methods typically assume a stationary detection volume of interest, whereas in this case, one must make adjustments for being able to see only a small portion of the region of interest and understand when an alert situation has occurred. To track object existence inside and outside the vehicle's sensor range, a probability of existence was defined for each hypothesized object, and this value was updated at every time step in a Bayesian manner based on expected characteristics of the sensor and object and whether that object has been detected in the most recent time step. Then, this value feeds into a sequential probability ratio test (SPRT) to determine the status of the object (suspected, confirmed, or deleted). Alerts are sent upon selected status transitions. Additionally, in order to track objects that move in and out of sensor range and update the probability of existence appropriately a variable probability detection has been defined and the hypothesis probability equations have been re-derived to accommodate this change. Unsupervised object tracking is a pervasive issue in automated perception systems. This work could apply to any mobile platform (ground vehicle, sea vessel, air vehicle, or orbiter) that intermittently revisits regions of interest and needs to determine whether anything interesting has changed.
47 CFR 10.450 - Geographic targeting.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Geographic targeting. 10.450 Section 10.450 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.450 Geographic targeting. This section establishes minimum requirements for the geographic...
47 CFR 10.400 - Classification.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Classification. 10.400 Section 10.400 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.400 Classification. A Participating CMS Provider is required to receive and transmit three...
47 CFR 10.400 - Classification.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Classification. 10.400 Section 10.400 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.400 Classification. A Participating CMS Provider is required to receive and transmit three...
47 CFR 10.400 - Classification.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Classification. 10.400 Section 10.400 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS Alert Message Requirements § 10.400 Classification. A Participating CMS Provider is required to receive and transmit three classes...
47 CFR 10.400 - Classification.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Classification. 10.400 Section 10.400 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.400 Classification. A Participating CMS Provider is required to receive and transmit three...
47 CFR 10.400 - Classification.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Classification. 10.400 Section 10.400 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS Alert Message Requirements § 10.400 Classification. A Participating CMS Provider is required to receive and transmit three classes...
Initial Evaluation of a Conflict Detection Tool in the Terminal Area
NASA Technical Reports Server (NTRS)
Verma Savita Arora; Tang, Huabin; Ballinger, Deborah S.; Kozon, Thomas E.; Farrahi, Amir Hossein
2012-01-01
Despite the recent economic recession and its adverse impact on air travel, the Federal Aviation Administration (FAA) continues to forecast an increase in air traffic demand that may see traffic double or triple by the year 2025. Increases in air traffic will burden the air traffic management system, and higher levels of safety and efficiency will be required. The air traffic controllers primary task is to ensure separation between aircraft in their airspace and keep the skies safe. As air traffic is forecasted to increase in volume and complexity [1], there is an increased likelihood of conflicts between aircraft, which adds risk and inefficiency to air traffic management and increases controller workload. To attenuate these factors, recent ATM research has shown that air and ground-based automation tools could reduce controller workload, especially if the automation is focused on conflict detection and resolution. Conflict Alert is a short time horizon conflict detection tool deployed in the Terminal Radar Approach Control (TRACON), which has limited utility due to the high number of false alerts generated and its use of dead reckoning to predict loss of separation between aircraft. Terminal Tactical Separation Assurance Flight Environment (T-TSAFE) is a short time horizon conflict detection tool that uses both flight intent and dead reckoning to detect conflicts. Results of a fast time simulation experiment indicated that TTSAFE provided a more effective alert lead-time and generated less false alerts than Conflict Alert [2]. TSAFE was previously tested in a Human-In-The-Loop (HITL) simulation study that focused on the en route phase of flight [3]. The current study tested the T-TSAFE tool in an HITL simulation study, focusing on the terminal environment with current day operations. The study identified procedures, roles, responsibilities, information requirements and usability, with the help of TRACON controllers who participated in the experiment. Metrics such as lead alert time, alert response time, workload, situation awareness and other measures were statistically analyzed. These metrics were examined from an overall perspective and comparisons between conditions (altitude resolutions via keyboard entry vs. ADS-B entry) and controller positions (two final approach sectors and two feeder sectors) were also examined. Results of these analyses and controller feedback provided evidence of T-TSAFE s potential promise as a useful air traffic controller tool. Heuristic analysis also provided information on ways in which the T-TSAFE tool can be improved. Details of analyses results will be presented in the full paper.
Roberts, David W; Schultz, Terry W; Api, Anne Marie
2016-10-01
The Local Lymph Node Assay (LLNA) is the gold standard regulatory toxicology test for skin sensitisation along with the guinea pig maximisation test (GPMT). Compared with the GPMT, LLNA uses fewer animals, it is quantitative, and it gives a numerical prediction of potency. However several concerns have been raised with this assay, mainly related to false positives and false negatives. Over the years, many authors, including the developers of the assay, have presented cases where there have been discrepancies between the GMPT and LLNA results. Several theories have been put forward for these discrepancies, the main one being the "over-sensitivity" of the GPMT. This paper analyses the data from a systematic study, published in three papers from 2008 to 2011, covering several classes of chemicals, in particular unsaturated fatty acids, sugar surfactants and ethoxylated alcohols, with many cases of chemicals testing positive in the LLNA being negative in the GPMT. Based on consideration of reaction chemistry and structural alerts, it is concluded that these discrepancies are not LLNA false positives, but can be rationalised in terms of the different protocols of the assays. Copyright © 2016 Elsevier Inc. All rights reserved.
Conditional Outlier Detection for Clinical Alerting
Hauskrecht, Milos; Valko, Michal; Batal, Iyad; Clermont, Gilles; Visweswaran, Shyam; Cooper, Gregory F.
2010-01-01
We develop and evaluate a data-driven approach for detecting unusual (anomalous) patient-management actions using past patient cases stored in an electronic health record (EHR) system. Our hypothesis is that patient-management actions that are unusual with respect to past patients may be due to a potential error and that it is worthwhile to raise an alert if such a condition is encountered. We evaluate this hypothesis using data obtained from the electronic health records of 4,486 post-cardiac surgical patients. We base the evaluation on the opinions of a panel of experts. The results support that anomaly-based alerting can have reasonably low false alert rates and that stronger anomalies are correlated with higher alert rates. PMID:21346986
Conditional outlier detection for clinical alerting.
Hauskrecht, Milos; Valko, Michal; Batal, Iyad; Clermont, Gilles; Visweswaran, Shyam; Cooper, Gregory F
2010-11-13
We develop and evaluate a data-driven approach for detecting unusual (anomalous) patient-management actions using past patient cases stored in an electronic health record (EHR) system. Our hypothesis is that patient-management actions that are unusual with respect to past patients may be due to a potential error and that it is worthwhile to raise an alert if such a condition is encountered. We evaluate this hypothesis using data obtained from the electronic health records of 4,486 post-cardiac surgical patients. We base the evaluation on the opinions of a panel of experts. The results support that anomaly-based alerting can have reasonably low false alert rates and that stronger anomalies are correlated with higher alert rates.
McGovern, Tracey N; Fitzgerald, John E
2008-10-01
The performance of mental alerting during caloric testing has always been considered important, however its use/benefit during electronystagmography (ENG)/videonystagmography (VNG) testing has been questioned. The aim of this study was to investigate the effect of mental alerting tasks on peripheral type vestibular nystagmus recorded during ENG. Thirty patients with significant spontaneous/gaze or positional nystagmus (slow phase velocity >or= 6 degrees /s) were recruited from consecutive referrals for vestibular assessment. Nystagmus was recorded by ENG both in the presence and absence of mental alerting for each patient. Investigation of nystagmus by analysis of variance (ANOVA) revealed significantly larger nystagmus (higher value SPV) with mental alerting than with no alerting (p<0.001), and for some patients nystagmus traces were reduced to a flat line (no nystagmus) with no alerting. The study demonstrates the importance of mental alerting in helping overcome central suppression of nystagmus and highlights its importance to help identify peripheral type nystagmus during ENG.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Roaming. 10.470 Section 10.470 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.470 Roaming. When, pursuant to a roaming agreement (see § 20.12 of this chapter), a...
47 CFR 10.210 - CMAS participation election procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false CMAS participation election procedures. 10.210 Section 10.210 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.210 CMAS participation election procedures...
47 CFR 10.440 - Embedded reference prohibition.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS Alert... address) to a resource on the Internet, or an embedded telephone number. This prohibition does not apply...
47 CFR 10.440 - Embedded reference prohibition.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS Alert... address) to a resource on the Internet, or an embedded telephone number. This prohibition does not apply...
Miyake, Noriko; Chong, Yong; Nishida, Ruriko; Nagasaki, Yoji; Kibe, Yasushi; Kiyosuke, Makiko; Shimomura, Takeshi; Shimono, Nobuyuki; Shimoda, Shinji; Akashi, Koichi
2015-11-01
In our hospital, positive blood culture rates of Helicobacter cinaedi dramatically increased after introducing the Bactec system. A simulated culture model of H. cinaedi bacteremia demonstrated no positive signals using the BacT/Alert system, despite efficient growth in bottles. Clinically suspected H. cinaedi bacteremia should be monitored more closely when using the BacT/Alert system, preferably with subcultivation after 7days of incubation. Copyright © 2015 Elsevier Inc. All rights reserved.
Airport Traffic Conflict Detection and Resolution Algorithm Evaluation
NASA Technical Reports Server (NTRS)
Jones, Denise R.; Chartrand, Ryan C.; Wilson, Sara R.; Commo, Sean A.; Ballard, Kathryn M.; Otero, Sharon D.; Barker, Glover D.
2016-01-01
Two conflict detection and resolution (CD&R) algorithms for the terminal maneuvering area (TMA) were evaluated in a fast-time batch simulation study at the National Aeronautics and Space Administration (NASA) Langley Research Center. One CD&R algorithm, developed at NASA, was designed to enhance surface situation awareness and provide cockpit alerts of potential conflicts during runway, taxi, and low altitude air-to-air operations. The second algorithm, Enhanced Traffic Situation Awareness on the Airport Surface with Indications and Alerts (SURF IA), was designed to increase flight crew awareness of the runway environment and facilitate an appropriate and timely response to potential conflict situations. The purpose of the study was to evaluate the performance of the aircraft-based CD&R algorithms during various runway, taxiway, and low altitude scenarios, multiple levels of CD&R system equipage, and various levels of horizontal position accuracy. Algorithm performance was assessed through various metrics including the collision rate, nuisance and missed alert rate, and alert toggling rate. The data suggests that, in general, alert toggling, nuisance and missed alerts, and unnecessary maneuvering occurred more frequently as the position accuracy was reduced. Collision avoidance was more effective when all of the aircraft were equipped with CD&R and maneuvered to avoid a collision after an alert was issued. In order to reduce the number of unwanted (nuisance) alerts when taxiing across a runway, a buffer is needed between the hold line and the alerting zone so alerts are not generated when an aircraft is behind the hold line. All of the results support RTCA horizontal position accuracy requirements for performing a CD&R function to reduce the likelihood and severity of runway incursions and collisions.
47 CFR 10.270 - Subscribers' right to terminate subscription.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Subscribers' right to terminate subscription. 10.270 Section 10.270 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.270 Subscribers' right to...
47 CFR 10.260 - Timing of subscriber notification.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Timing of subscriber notification. 10.260 Section 10.260 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.260 Timing of subscriber notification. A CMS...
Handler beliefs affect scent detection dog outcomes.
Lit, Lisa; Schweitzer, Julie B; Oberbauer, Anita M
2011-05-01
Our aim was to evaluate how human beliefs affect working dog outcomes in an applied environment. We asked whether beliefs of scent detection dog handlers affect team performance and evaluated relative importance of human versus dog influences on handlers' beliefs. Eighteen drug and/or explosive detection dog/handler teams each completed two sets of four brief search scenarios (conditions). Handlers were falsely told that two conditions contained a paper marking scent location (human influence). Two conditions contained decoy scents (food/toy) to encourage dog interest in a false location (dog influence). Conditions were (1) control; (2) paper marker; (3) decoy scent; and (4) paper marker at decoy scent. No conditions contained drug or explosive scent; any alerting response was incorrect. A repeated measures analysis of variance was used with search condition as the independent variable and number of alerts as the dependent variable. Additional nonparametric tests compared human and dog influence. There were 225 incorrect responses, with no differences in mean responses across conditions. Response patterns differed by condition. There were more correct (no alert responses) searches in conditions without markers. Within marked conditions, handlers reported that dogs alerted more at marked locations than other locations. Handlers' beliefs that scent was present potentiated handler identification of detection dog alerts. Human more than dog influences affected alert locations. This confirms that handler beliefs affect outcomes of scent detection dog deployments.
NASA Astrophysics Data System (ADS)
Souvatzoglou, G.; Papaioannou, A.; Mavromichalaki, H.; Dimitroulakos, J.; Sarlanis, C.
2014-11-01
Whenever a significant intensity increase is being recorded by at least three neutron monitor stations in real-time mode, a ground level enhancement (GLE) event is marked and an automated alert is issued. Although, the physical concept of the algorithm is solid and has efficiently worked in a number of cases, the availability of real-time data is still an open issue and makes timely GLE alerts quite challenging. In this work we present the optimization of the GLE alert that has been set into operation since 2006 at the Athens Neutron Monitor Station. This upgrade has led to GLE Alert Plus, which is currently based upon the Neutron Monitor Database (NMDB). We have determined the critical values per station allowing us to issue reliable GLE alerts close to the initiation of the event while at the same time we keep the false alert rate at low levels. Furthermore, we have managed to treat the problem of data availability, introducing the Go-Back-N algorithm. A total of 13 GLE events have been marked from January 2000 to December 2012. GLE Alert Plus issued an alert for 12 events. These alert times are compared to the alert times of GOES Space Weather Prediction Center and Solar Energetic Particle forecaster of the University of Málaga (UMASEP). In all cases GLE Alert Plus precedes the GOES alert by ≈8-52 min. The comparison with UMASEP demonstrated a remarkably good agreement. Real-time GLE alerts by GLE Alert Plus may be retrieved by http://cosray.phys.uoa.gr/gle_alert_plus.html, http://www.nmdb.eu, and http://swe.ssa.esa.int/web/guest/space-radiation. An automated GLE alert email notification system is also available to interested users.
Sutter, Martin A.; Grob, Dieter; Jeszenszky, Dezsö; Porchet, François; Dvorak, Jiri
2007-01-01
A prospective study of 246 patients who received multimodal intraoperative monitoring during cervical spine surgery between March 2000 and December 2005. To determine the sensitivity and specificity of MIOM techniques used to monitor spinal cord and nerve root function during cervical spine surgery. It is appreciated that complication rate of cervical spine surgery is low, however, there is a significant risk of neurological injury. The combination of monitoring of ascending and descending pathways may provide more sensitive and specific results giving immediate feedback information and/or alert regarding any neurological changes during the operation to the surgeon. Intraoperative somatosensory spinal and cerebral evoked potentials combined with continuous EMG and motor-evoked potentials of the spinal cord and muscles were evaluated and compared with postoperative clinical neurological changes. A total of 246 consecutive patients with cervical pathologies, majority spinal stenosis due to degenerative changes of cervical spine were monitored by means of MIOM during the surgical procedure. About 232 patients presented true negative while 2 patients false negative responses. About ten patients presented true positive responses where neurological deficit after the operation was predicted and two patients presented false positive findings. The sensitivity of MIOM applied during cervical spine procedure (anterior and/or posterior) was 83.3% and specificity of 99.2%. MIOM is an effective method of monitoring the spinal cord functional integrity during cervical spine surgery and can help to reduce the risk of neurological deficit by alerting the surgeon when monitoring changes are observed. PMID:17610090
Brown, Samuel M; Jones, Jason; Kuttler, Kathryn Gibb; Keddington, Roger K; Allen, Todd L; Haug, Peter
2016-08-22
Sepsis is an often-fatal syndrome resulting from severe infection. Rapid identification and treatment are critical for septic patients. We therefore developed a probabilistic model to identify septic patients in the emergency department (ED). We aimed to produce a model that identifies 80 % of sepsis patients, with no more than 15 false positive alerts per day, within one hour of ED admission, using routine clinical data. We developed the model using retrospective data for 132,748 ED encounters (549 septic), with manual chart review to confirm cases of severe sepsis or septic shock from January 2006 through December 2008. A naïve Bayes model was used to select model features, starting with clinician-proposed candidate variables, which were then used to calculate the probability of sepsis. We evaluated the accuracy of the resulting model in 93,733 ED encounters from April 2009 through June 2010. The final model included mean blood pressure, temperature, age, heart rate, and white blood cell count. The area under the receiver operating characteristic curve (AUC) for the continuous predictor model was 0.953. The binary alert achieved 76.4 % sensitivity with a false positive rate of 4.7 %. We developed and validated a probabilistic model to identify sepsis early in an ED encounter. Despite changes in process, organizational focus, and the H1N1 influenza pandemic, our model performed adequately in our validation cohort, suggesting that it will be generalizable.
47 CFR 10.230 - New CMS providers participation in CMAS.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false New CMS providers participation in CMAS. 10.230 Section 10.230 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.230 New CMS providers participation in CMAS...
47 CFR 10.250 - Notification to existing subscribers of non-participation in CMAS.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Notification to existing subscribers of non-participation in CMAS. 10.250 Section 10.250 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.250...
47 CFR 10.280 - Subscribers' right to opt out of CMAS notifications.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Subscribers' right to opt out of CMAS notifications. 10.280 Section 10.280 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.280 Subscribers' right...
44 CFR 208.36 - Reimbursement for Alert.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Reimbursement for Alert. 208.36 Section 208.36 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT... § 208.41 of this part. (4) Food and beverages for Task Force Members and Support Specialists when DHS...
Adaptive sequential Bayesian classification using Page's test
NASA Astrophysics Data System (ADS)
Lynch, Robert S., Jr.; Willett, Peter K.
2002-03-01
In this paper, the previously introduced Mean-Field Bayesian Data Reduction Algorithm is extended for adaptive sequential hypothesis testing utilizing Page's test. In general, Page's test is well understood as a method of detecting a permanent change in distribution associated with a sequence of observations. However, the relationship between detecting a change in distribution utilizing Page's test with that of classification and feature fusion is not well understood. Thus, the contribution of this work is based on developing a method of classifying an unlabeled vector of fused features (i.e., detect a change to an active statistical state) as quickly as possible given an acceptable mean time between false alerts. In this case, the developed classification test can be thought of as equivalent to performing a sequential probability ratio test repeatedly until a class is decided, with the lower log-threshold of each test being set to zero and the upper log-threshold being determined by the expected distance between false alerts. It is of interest to estimate the delay (or, related stopping time) to a classification decision (the number of time samples it takes to classify the target), and the mean time between false alerts, as a function of feature selection and fusion by the Mean-Field Bayesian Data Reduction Algorithm. Results are demonstrated by plotting the delay to declaring the target class versus the mean time between false alerts, and are shown using both different numbers of simulated training data and different numbers of relevant features for each class.
Page, N; Baysari, M T; Westbrook, J I
2017-09-01
To assess the evidence of the effectiveness of different categories of interruptive medication prescribing alerts to change prescriber behavior and/or improve patient outcomes in hospital computerized provider order entry (CPOE) systems. PubMed, Embase, CINAHL and the Cochrane Library were searched for relevant articles published between January 2000 and February 2016. Studies were included if they compared the outcomes of automatic, interruptive medication prescribing alert/s to a control/comparison group to determine alert effectiveness. Twenty-three studies describing 32 alerts classified into 11 alert categories were identified. The most common alert categories studied were drug-condition interaction (n=6), drug-drug interaction alerts (n=6) and corollary order alerts (n=6). All 23 papers investigated the effect of the intervention alert on at least one outcome measure of prescriber behavior. Just over half of the studies (53%, n=17) reported a statistically significant beneficial effect from the intervention alert; 34% (n=11) reported no statistically significant effect, and 6% (n=2) reported a significant detrimental effect. Two studies also evaluated the effect of alerts on patient outcome measures; neither finding that patient outcomes significantly improved following alert implementation (6%, n=2). The greatest volume of evidence relates to three alert categories: drug-condition, drug-drug and corollary order alerts. Of these, drug-condition alerts had the greatest number of studies reporting positive effects (five out of six studies). Only two of six studies of drug-drug interaction and one of six of corollary alerts reported positive benefits. The current evidence-base does not show a clear indication that particular categories of alerts are more effective than others. While the majority of alert categories were shown to improve outcomes in some studies, there were also many cases where outcomes did not improve. This lack of evidence hinders decisions about the amount and type of decision support that should be integrated into CPOE systems to increase safety while reducing the risk of alert fatigue. Virtually no studies have sought to investigate the impact on changes to prescriber behavior and outcomes overall when alerts from multiple categories are incorporated within the same system. Copyright © 2017 Elsevier B.V. All rights reserved.
Sensitivity and specificity of dosing alerts for dosing errors among hospitalized pediatric patients
Stultz, Jeremy S; Porter, Kyle; Nahata, Milap C
2014-01-01
Objectives To determine the sensitivity and specificity of a dosing alert system for dosing errors and to compare the sensitivity of a proprietary system with and without institutional customization at a pediatric hospital. Methods A retrospective analysis of medication orders, orders causing dosing alerts, reported adverse drug events, and dosing errors during July, 2011 was conducted. Dosing errors with and without alerts were identified and the sensitivity of the system with and without customization was compared. Results There were 47 181 inpatient pediatric orders during the studied period; 257 dosing errors were identified (0.54%). The sensitivity of the system for identifying dosing errors was 54.1% (95% CI 47.8% to 60.3%) if customization had not occurred and increased to 60.3% (CI 54.0% to 66.3%) with customization (p=0.02). The sensitivity of the system for underdoses was 49.6% without customization and 60.3% with customization (p=0.01). Specificity of the customized system for dosing errors was 96.2% (CI 96.0% to 96.3%) with a positive predictive value of 8.0% (CI 6.8% to 9.3). All dosing errors had an alert over-ridden by the prescriber and 40.6% of dosing errors with alerts were administered to the patient. The lack of indication-specific dose ranges was the most common reason why an alert did not occur for a dosing error. Discussion Advances in dosing alert systems should aim to improve the sensitivity and positive predictive value of the system for dosing errors. Conclusions The dosing alert system had a low sensitivity and positive predictive value for dosing errors, but might have prevented dosing errors from reaching patients. Customization increased the sensitivity of the system for dosing errors. PMID:24496386
Report: Management Alert - Salary Increases for Certain Administratively Determined Positions
Report #18-N-0154, April 16, 2018. The purpose of this alert is to notify the EPA of certain factual info while our audit of the Office of the Administrator's (present and prior administrations) use of administratively determined positions continues.
Postural control system influences intrinsic alerting state.
Barra, Julien; Auclair, Laurent; Charvillat, Agnès; Vidal, Manuel; Pérennou, Dominic
2015-03-01
Numerous studies using dual-task paradigms (postural and cognitive) have shown that postural control requires cognitive resources. However, the influence of postural control on attention components has never been directly addressed. Using the attention network test (ANT), which assesses specifically each of the 3 components of attention-alertness, orientation, and executive control-within a single paradigm, we investigated the effect of postural balance demand on these 3 components. Forty-two participants completed the ANT in 3 postural conditions: (a) supine, a very stable position; (b) sitting on a chair, an intermediate position; and (c) standing with feet lined up heel to toe, a very instable position known as the Romberg position. Our results revealed that the difficulty of postural control does modulate alerting in such a way that it improves with the level of instability of the position. Regarding the orienting and executive control components of attention, performance was not different when participants were standing upright or seated, whereas in the supine position, performance dropped. The strong and specific interaction between postural control and the alerting system suggests that these mechanisms may share parts of the underlying neural circuits. We discuss the possible implication of the locus coeruleus, known to be involved in both postural balance and alerting. Also, our findings concerning orienting and executive control systems suggest that supine posture could have a specific effect on cognitive activities. These effects are discussed in terms of particularities resulting from the supine position. PsycINFO Database Record (c) 2015 APA, all rights reserved.
Fiori, Barbara; D'Inzeo, Tiziana; Di Florio, Viviana; De Maio, Flavio; De Angelis, Giulia; Giaquinto, Alessia; Campana, Lara; Tanzarella, Eloisa; Tumbarello, Mario; Antonelli, Massimo; Spanu, Teresa
2014-01-01
We compared the clinical performances of the BacT/Alert Plus (bioMérieux) and Bactec Plus (Becton Dickinson) aerobic and anaerobic blood culture (BC) media with adsorbent polymeric beads. Patients ≥16 years old with suspected bloodstream infections (BSIs) were enrolled in intensive care units and infectious disease wards. A single 40-ml blood sample was collected from each and used to inoculate (10 ml/bottle) one set of BacT/Alert Plus cultures and one set of Bactec Plus cultures, each set consisting of one aerobic and one anaerobic bottle. Cultures were incubated ≤5 days in the BacT/Alert 3D and Bactec FX instruments, respectively. A total of 128 unique BSI episodes were identified based on the recovery of clinically significant growth in 212 aerobic cultures (106 BacT/Alert and 106 Bactec) and 151 anaerobic cultures (82 BacT/Alert and 69 Bactec). The BacT/Alert aerobic medium had higher recovery rates for Gram-positive cocci (P = 0.024), whereas the Bactec aerobic medium was superior for recovery of Gram-negative bacilli (P = 0.006). BacT/Alert anaerobic medium recovery rates exceeded those of the Bactec anaerobic medium for total organisms (P = 0.003), Gram-positive cocci (P = 0.013), and Escherichia coli (P = 0.030). In terms of capacity for diagnosing the 128 septic episodes, the BacT/Alert and Bactec sets were comparable, although the former sets diagnosed more BSIs caused by Gram-positive cocci (P = 0.008). They also allowed earlier identification of coagulase-negative staphylococcal growth (mean, 2.8 h; P = 0.003) and growth in samples from patients not on antimicrobial therapy that yielded positive results (mean, 1.3 h; P < 0.001). Similarly high percentages of microorganisms in BacT/Alert and Bactec cultures (93.8% and 93.3%, respectively) were identified by direct matrix-assisted laser desorption ionization–time of flight mass spectrometry assay of BC broths. The BacT/Alert Plus media line appears to be a reliable, timesaving tool for routine detection of BSIs in the population we studied, although further studies are needed to evaluate their performance in other settings. PMID:25031441
Bode, Bruce; Gross, Kenneth; Rikalo, Nancy; Schwartz, Sherwyn; Wahl, Timothy; Page, Casey; Gross, Todd; Mastrototaro, John
2004-04-01
The purposes of this study were to demonstrate the accuracy and effectiveness of the Guardian Continuous Monitoring System (Medtronic MiniMed, Northridge, California) and to demonstrate that the application of real-time alarms to continuous monitoring alerts users to hypo and hyperglycemia and reduces excursions in people with diabetes. A total of 71 subjects with type 1 diabetes, mean hemoglobin A1c of 7.6 +/- 1.1%, age 44.0 +/- 11.4 years, and duration of diabetes 23.6 +/- 10.6 years were enrolled in this two-period, randomized, multicenter study. Subjects were randomized into either an Alert group or a Control group. The accuracy of the Guardian was evaluated by treating the study data as a single-sample correlational design. Effectiveness of the Guardian alerts was evaluated by comparing the Alert group with the Control group. The mean (median) absolute relative error between home blood glucose meter readings and sensor values was 21.3% (17.3%), and the Guardian, on average, read 12.8 mg/dL below the concurrent home blood glucose meter readings. The hypoglycemia alert was able to distinguished glucose values < or =70 mg/dL with 67% sensitivity, 90% specificity, and 47% false alerts. The hyperglycemia alert showed a similar ability to detect sensor values > or =250 mg/dL with 63% sensitivity, 97% specificity, and 19% false alerts. The Alert group demonstrated a median decrease in the duration of hypoglycemic excursions (-27.8 min) that was significantly greater than the median decrease in the duration of hypoglycemic excursions in the Control group (-4.5 min) (P = 0.03). A marginally significant increase in the frequency of hyperglycemic excursions (P = 0.07) between Period 1 and Period 2 was accompanied by a decrease of 9.6 min in the duration of hyperglycemic excursions in the Alert group. Glucose measurements differ between blood samples taken from the finger and interstitial fluid, especially when levels are changing rapidly; however, these results demonstrate that the Guardian is reasonably accurate while performing continuous glucose monitoring. The subjects' responses to hypoglycemia alerts resulted in a significant reduction in the duration of hypoglycemic excursions; however, overtreating hypoglycemia may have resulted in a marginally significant increase in the frequency of hyperglycemic excursions.
Analysis of UAS DAA Alerting in Fast-Time Simulations without DAA Mitigation
NASA Technical Reports Server (NTRS)
Thipphavong, David P.; Santiago, Confesor; Isaacson, Douglas R.; Lee, Seung Man; Park, Chunki; Refai, Mohamad Said; Snow, James
2015-01-01
Realization of the expected proliferation of Unmanned Aircraft System (UAS) operations in the National Airspace System (NAS) depends on the development and validation of performance standards for UAS Detect and Avoid (DAA) Systems. The RTCA Special Committee 228 is charged with leading the development of draft Minimum Operational Performance Standards (MOPS) for UAS DAA Systems. NASA, as a participating member of RTCA SC-228 is committed to supporting the development and validation of draft requirements for DAA alerting system performance. A recent study conducted using NASA's ACES (Airspace Concept Evaluation System) simulation capability begins to address questions surrounding the development of draft MOPS for DAA alerting systems. ACES simulations were conducted to study the performance of alerting systems proposed by the SC-228 DAA Alerting sub-group. Analysis included but was not limited to: 1) correct alert (and timeliness), 2) false alert (and severity and duration), 3) missed alert, and 4) probability of an alert type at the time of loss of well clear. The performance of DAA alerting systems when using intent vs. dead-reckoning for UAS ownship trajectories was also compared. The results will be used by SC-228 to inform decisions about the surveillance standards of UAS DAA systems and future requirements development and validation efforts.
Practitioners’ Views on Computerized Drug–Drug Interaction Alerts in the VA System
Ko, Yu; Abarca, Jacob; Malone, Daniel C.; Dare, Donna C.; Geraets, Doug; Houranieh, Antoun; Jones, William N.; Nichol, W. Paul; Schepers, Gregory P.; Wilhardt, Michelle
2007-01-01
Objectives To assess Veterans Affairs (VA) prescribers’ and pharmacists’ opinions about computer-generated drug–drug interaction (DDI) alerts and obtain suggestions for improving DDI alerts. Design A mail survey of 725 prescribers and 142 pharmacists from seven VA medical centers across the United States. Measurements A questionnaire asked respondents about their sources of drug and DDI information, satisfaction with the combined inpatient and outpatient computerized prescriber order entry (CPOE) system, attitude toward DDI alerts, and suggestions for improving DDI alerts. Results The overall response rate was 40% (prescribers: 36%; pharmacists: 59%). Both prescribers and pharmacists indicated that the CPOE system had a neutral to positive impact on their jobs. DDI alerts were not viewed as a waste of time and the majority (61%) of prescribers felt that DDI alerts had increased their potential to prescribe safely. However, only 30% of prescribers felt DDI alerts provided them with what they needed most of the time. Both prescribers and pharmacists agreed that DDI alerts should be accompanied by management alternatives (73% and 82%, respectively) and more detailed information (65% and 89%, respectively). When asked about suggestions for improving DDI alerts, prescribers most preferred including management options whereas pharmacists most preferred making it more difficult to override lethal interactions. Prescribers and pharmacists reported primarily relying on electronic references for general drug information (62% and 55%, respectively) and DDI information (51% and 79%, respectively). Conclusion Respondents reported neutral to positive views regarding the effect of CPOE on their jobs. Their opinions suggest DDI alerts are useful but still require additional work to increase their clinical utility. PMID:17068346
Bacterial contamination of platelet components not detected by BacT/ALERT®.
Abela, M A; Fenning, S; Maguire, K A; Morris, K G
2018-02-01
To investigate the possible causes for false negative results in BacT/ALERT ® 3D Signature System despite bacterial contamination of platelet units. The Northern Ireland Blood Transfusion Service (NIBTS) routinely extends platelet component shelf life to 7 days. Components are sampled and screened for bacterial contamination using an automated microbial detection system, the BacT/ALERT ® 3D Signature System. We report on three platelet components with confirmed bacterial contamination, which represent false negative BacT/ALERT ® results and near-miss serious adverse events. NIBTS protocols for risk reduction of bacterial contamination of platelet components are described. The methodology for bacterial detection using BacT/ALERT ® is outlined. Laboratory tests, relevant patient details and relevant follow-up information are analysed. In all three cases, Staphylococcus aureus was isolated from the platelet residue and confirmed on terminal sub-culture using BacT/ALERT ® . In two cases, S. aureus with similar genetic makeup was isolated from the donors. Risk reduction measures for bacterial contamination of platelet components are not always effective. Automated bacterial culture detection does not eliminate the risk of bacterial contamination. Visual inspection of platelet components prior to release, issue and administration remains an important last line of defence. © 2017 British Blood Transfusion Society.
47 CFR 10.280 - Subscribers' right to opt out of CMAS notifications.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Subscribers' right to opt out of CMAS... MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.280 Subscribers' right to opt out of CMAS notifications. (a) CMS providers may provide their subscribers with the option to...
47 CFR 10.280 - Subscribers' right to opt out of CMAS notifications.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Subscribers' right to opt out of CMAS... MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.280 Subscribers' right to opt out of CMAS notifications. (a) CMS providers may provide their subscribers with the option to...
47 CFR 80.1115 - Transmission of a distress alert by a station not itself in distress.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Transmission of a distress alert by a station not itself in distress. 80.1115 Section 80.1115 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and...
47 CFR 80.1115 - Transmission of a distress alert by a station not itself in distress.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Transmission of a distress alert by a station not itself in distress. 80.1115 Section 80.1115 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and...
47 CFR 11.11 - The Emergency Alert System (EAS).
Code of Federal Regulations, 2014 CFR
2014-10-01
... through the use of a single set of EAS equipment at the hub station (or common studio or control point... the FCC in any agreements. (e) Other technologies and public service providers, such as low earth... 47 Telecommunication 1 2014-10-01 2014-10-01 false The Emergency Alert System (EAS). 11.11 Section...
47 CFR 11.11 - The Emergency Alert System (EAS).
Code of Federal Regulations, 2013 CFR
2013-10-01
... through the use of a single set of EAS equipment at the hub station (or common studio or control point... the FCC in any agreements. (e) Other technologies and public service providers, such as low earth... 47 Telecommunication 1 2013-10-01 2013-10-01 false The Emergency Alert System (EAS). 11.11 Section...
47 CFR 11.11 - The Emergency Alert System (EAS).
Code of Federal Regulations, 2012 CFR
2012-10-01
... through the use of a single set of EAS equipment at the hub station (or common studio or control point... the FCC in any agreements. (e) Other technologies and public service providers, such as low earth... 47 Telecommunication 1 2012-10-01 2012-10-01 false The Emergency Alert System (EAS). 11.11 Section...
Doshi-Velez, Finale; Li, William; Battat, Yoni; Charrow, Ben; Curtis, Dorothy; Curthis, Dorothy; Park, Jun-geun; Hemachandra, Sachithra; Velez, Javier; Walsh, Cynthia; Fredette, Don; Reimer, Bryan; Roy, Nicholas; Teller, Seth
2012-07-01
To assess the effectiveness of a wireless network (WiFi-based) localization system (devices mounted on resident wheelchairs) in decreasing caretaker time spent searching for residents and providing alerts of residents going outdoors in a skilled nursing facility. A controlled study over two 2-month periods approved by the institutional review board. A long-term skilled nursing facility in Massachusetts specializing in multiple sclerosis previously instrumented with wireless network infrastructure. Nineteen residents and 9 staff members at the facility for the first 2-month period; 9 residents and 3 staff members at the facility for the second 2-month period. Software was installed on 4 staff computers to display the locations of residents enrolled in the study. This software was made available to enrolled staff for the second half of the first 2-month period and the entirety of the second 2-month study. In the second 2-month study, the software was modified to provide alerts if any 1 of 9 participating "high-risk"' residents went outdoors, and the accuracy of the alert system was evaluated. In the first 2-month study, 9 staff members recorded the amount of time it took them to locate participating residents (as and when needed during the course of their daily activities). In the second 2-month study, 3 staff members recorded whether outdoor-alerts correctly identified a resident leaving the building or if it was a false alarm. In both phases, participating staff members made frequent use of the system (44 searches and 215 outdoor alerts). Overall, the localization information decreased the average time needed to find residents by about two-thirds (from 311.1 seconds to 110.9 seconds). For outdoor alerts, the system had a false-alarm rate of 9.1% (under normal facility operations); systematic tests of the outdoor-alert system carried out by the authors had a false-negative, or missed-alarm, rate of 1.7%. Using timely resident location information can provide significant gains for both operational efficiency (finding residents) and enhanced resident safety (outdoor alerts). This approach may provide an inexpensive alternative for facilities that have sufficient wireless infrastructure; future work should assess its effectiveness in additional settings. Copyright © 2012 American Medical Directors Association. Published by Elsevier Inc. All rights reserved.
Flight crew interface aspects of forward-looking airborne windshear detection systems
NASA Technical Reports Server (NTRS)
Anderson, Charles D.; Carbaugh, David C.
1993-01-01
The goal of this research effort was to conduct analyses and research which could provide guidelines for design of the crew interface of an integrated windshear system. Addressed were HF issues, crew/system requirements, candidate display formats, alerting criteria, and crew procedures. A survey identified five flight management issues as top priority: missed alert acceptability; avoidance distance needed; false alert acceptability; nuisance rate acceptability; and crew procedures. Results of a simulation study indicated that the warning time for a look-ahead alert needs to be between 11 and 36 seconds (target of 23 seconds) before the reactive system triggers in order to be effective. Pilots considered the standard go-around maneuver most appropriate for look-ahead alerts, and the escape maneuvers used did not require lateral turns. Prototype display formats were reviewed or developed for alerting the crew; providing guidance to avoid or escape windshear; and status displays to provide windshear situational awareness. The three alerting levels now in use were considered appropriate, with a fourth (time-critical) level as a possible addition, although many reviewers felt only two levels of alerting were needed. Another survey gathered expert opinion on what crew procedures and alerting criteria should be used for look-ahead, or integrated, windshear systems, with a wide diversity of opinion in these areas.
DANTi: Detect and Avoid iN The Cockpit
NASA Technical Reports Server (NTRS)
Chamberlain, James; Consiglio, Maria; Munoz, Cesar
2017-01-01
Mid-air collision risk continues to be a concern for manned aircraft operations, especially near busy non-towered airports. The use of Detect and Avoid (DAA) technologies and draft standards developed for unmanned aircraft systems (UAS), either alone or in combination with other collision avoidance technologies, may be useful in mitigating this collision risk for manned aircraft. This paper describes a NASA research effort known as DANTi (DAA iN The Cockpit), including the initial development of the concept of use, a software prototype, and results from initial flight tests conducted with this prototype. The prototype used a single Automatic Dependent Surveillance - Broadcast (ADS-B) traffic sensor and the own aircraft's position, track, heading and air data information, along with NASA-developed DAA software to display traffic alerts and maneuver guidance to manned aircraft pilots on a portable tablet device. Initial flight tests with the prototype showed a successful DANTi proof-of-concept, but also demonstrated that the traffic separation parameter set specified in the RTCA SC-228 Phase I DAA MOPS may generate excessive false alerts during traffic pattern operations. Several parameter sets with smaller separation values were also tested in flight, one of which yielded more timely alerts for the maneuvers tested. Results from this study may further inform future DANTi efforts as well as Phase II DAA MOPS development.
47 CFR 11.11 - The Emergency Alert System (EAS).
Code of Federal Regulations, 2010 CFR
2010-10-01
... through the use of a single set of EAS equipment at the hub station (or common studio or control point... as low earth orbiting satellites, that wish to participate in the EAS may contact the FCC's Public... 47 Telecommunication 1 2010-10-01 2010-10-01 false The Emergency Alert System (EAS). 11.11 Section...
47 CFR 11.11 - The Emergency Alert System (EAS).
Code of Federal Regulations, 2011 CFR
2011-10-01
... through the use of a single set of EAS equipment at the hub station (or common studio or control point... as low earth orbiting satellites, that wish to participate in the EAS may contact the FCC's Public... 47 Telecommunication 1 2011-10-01 2011-10-01 false The Emergency Alert System (EAS). 11.11 Section...
Fiori, Barbara; D'Inzeo, Tiziana; Di Florio, Viviana; De Maio, Flavio; De Angelis, Giulia; Giaquinto, Alessia; Campana, Lara; Tanzarella, Eloisa; Tumbarello, Mario; Antonelli, Massimo; Sanguinetti, Maurizio; Spanu, Teresa
2014-10-01
We compared the clinical performances of the BacT/Alert Plus (bioMérieux) and Bactec Plus (Becton Dickinson) aerobic and anaerobic blood culture (BC) media with adsorbent polymeric beads. Patients ≥ 16 years old with suspected bloodstream infections (BSIs) were enrolled in intensive care units and infectious disease wards. A single 40-ml blood sample was collected from each and used to inoculate (10 ml/bottle) one set of BacT/Alert Plus cultures and one set of Bactec Plus cultures, each set consisting of one aerobic and one anaerobic bottle. Cultures were incubated ≤ 5 days in the BacT/Alert 3D and Bactec FX instruments, respectively. A total of 128 unique BSI episodes were identified based on the recovery of clinically significant growth in 212 aerobic cultures (106 BacT/Alert and 106 Bactec) and 151 anaerobic cultures (82 BacT/Alert and 69 Bactec). The BacT/Alert aerobic medium had higher recovery rates for Gram-positive cocci (P = 0.024), whereas the Bactec aerobic medium was superior for recovery of Gram-negative bacilli (P = 0.006). BacT/Alert anaerobic medium recovery rates exceeded those of the Bactec anaerobic medium for total organisms (P = 0.003), Gram-positive cocci (P = 0.013), and Escherichia coli (P = 0.030). In terms of capacity for diagnosing the 128 septic episodes, the BacT/Alert and Bactec sets were comparable, although the former sets diagnosed more BSIs caused by Gram-positive cocci (P = 0.008). They also allowed earlier identification of coagulase-negative staphylococcal growth (mean, 2.8 h; P = 0.003) and growth in samples from patients not on antimicrobial therapy that yielded positive results (mean, 1.3 h; P < 0.001). Similarly high percentages of microorganisms in BacT/Alert and Bactec cultures (93.8% and 93.3%, respectively) were identified by direct matrix-assisted laser desorption ionization-time of flight mass spectrometry assay of BC broths. The BacT/Alert Plus media line appears to be a reliable, timesaving tool for routine detection of BSIs in the population we studied, although further studies are needed to evaluate their performance in other settings. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Real-Time Detection of Infusion Site Failures in a Closed-Loop Artificial Pancreas.
Howsmon, Daniel P; Baysal, Nihat; Buckingham, Bruce A; Forlenza, Gregory P; Ly, Trang T; Maahs, David M; Marcal, Tatiana; Towers, Lindsey; Mauritzen, Eric; Deshpande, Sunil; Huyett, Lauren M; Pinsker, Jordan E; Gondhalekar, Ravi; Doyle, Francis J; Dassau, Eyal; Hahn, Juergen; Bequette, B Wayne
2018-05-01
As evidence emerges that artificial pancreas systems improve clinical outcomes for patients with type 1 diabetes, the burden of this disease will hopefully begin to be alleviated for many patients and caregivers. However, reliance on automated insulin delivery potentially means patients will be slower to act when devices stop functioning appropriately. One such scenario involves an insulin infusion site failure, where the insulin that is recorded as delivered fails to affect the patient's glucose as expected. Alerting patients to these events in real time would potentially reduce hyperglycemia and ketosis associated with infusion site failures. An infusion site failure detection algorithm was deployed in a randomized crossover study with artificial pancreas and sensor-augmented pump arms in an outpatient setting. Each arm lasted two weeks. Nineteen participants wore infusion sets for up to 7 days. Clinicians contacted patients to confirm infusion site failures detected by the algorithm and instructed on set replacement if failure was confirmed. In real time and under zone model predictive control, the infusion site failure detection algorithm achieved a sensitivity of 88.0% (n = 25) while issuing only 0.22 false positives per day, compared with a sensitivity of 73.3% (n = 15) and 0.27 false positives per day in the SAP arm (as indicated by retrospective analysis). No association between intervention strategy and duration of infusion sets was observed ( P = .58). As patient burden is reduced by each generation of advanced diabetes technology, fault detection algorithms will help ensure that patients are alerted when they need to manually intervene. Clinical Trial Identifier: www.clinicaltrials.gov,NCT02773875.
A Comparative Analysis of the Snort and Suricata Intrusion-Detection Systems
2011-09-01
Category: Test Rules Test #6: Simple LFI Attack 43 Snort True Positive: Snort generated an alert based on the ‘/etc/ passwd ’ string passed...through an HTTP command. Suricata True Positive: Suricata generated an alert based on the ‘/etc/ passwd ’ string passed through an HTTP command
Cuéllar Monreal, Mª Jesús; Reig Aguado, Jorge; Font Noguera, Isabel; Poveda Andrés, José Luis
2017-01-01
To reduce the alert fatigue in our Assisted Electronic Prescribing System (AEPS), through the Lean Six Sigma (LSS) methodology. An observational (transversal) and retrospective study, in a general hospital with 850 beds and AEPS. The LSS methodology was followed in order to evaluate the alert fatigue situation in the AEPS system, to implement improvements, and to assess outcomes. The alerts generated during two trimesters studied (before and after the intervention) were analyzed. In order to measure the qualitative indicators, the most frequent alert types were analyzed, as well as the molecules responsible for over 50% of each type of alert. The action by the prescriber was analyzed in a sample of 496 prescriptions that generated such alerts. For each type of alert and molecule, there was a prioritization of the improvements to be implemented according to the alert generated and its quality. A second survey evaluated the pharmacist action for the alerts most highly valued by physicians. The problem, the objective, the work team and the project schedule were defined. A survey was designed in order to understand the opinion of the client about the alert system in the program. Based on the surveys collected (n = 136), the critical characteristics and the quanti/qualitative indicators were defined. Sixty (60) fields in the alert system were modified, corresponding to 32 molecules, and this led to a 28% reduction in the total number of alerts. Regarding quality indicators, false po sitive results were reduced by 25% (p < 0.05), 100% of those alerts ignored with justification were sustained, and there were no significant differences in user adherence to the system. The project improvements and outcomes were reviewed by the work team. LSS methodology has demonstrated being a valid tool for the quantitative and qualitative improvement of the alert system in an Assisted Electronic Prescription Program, thus reducing alert fatigue. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
Downing, N. Lance; Shepard, John; Chu, Weihan; Tam, Julia; Wessels, Alexander; Li, Ron; Dietrich, Brian; Rudy, Michael; Castaneda, Leon; Shieh, Lisa
2016-01-01
Summary Bachground Increasing use of EHRs has generated interest in the potential of computerized clinical decision support to improve treatment of sepsis. Electronic sepsis alerts have had mixed results due to poor test characteristics, the inability to detect sepsis in a timely fashion and the use of outside software limiting widespread adoption. We describe the development, evaluation and validation of an accurate and timely severe sepsis alert with the potential to impact sepsis management. Objective To develop, evaluate, and validate an accurate and timely severe sepsis alert embedded in a commercial EHR. Methods The sepsis alert was developed by identifying the most common severe sepsis criteria among a cohort of patients with ICD 9 codes indicating a diagnosis of sepsis. This alert requires criteria in three categories: indicators of a systemic inflammatory response, evidence of suspected infection from physician orders, and markers of organ dysfunction. Chart review was used to evaluate test performance and the ability to detect clinical time zero, the point in time when a patient develops severe sepsis. Results Two physicians reviewed 100 positive cases and 75 negative cases. Based on this review, sensitivity was 74.5%, specificity was 86.0%, the positive predictive value was 50.3%, and the negative predictive value was 94.7%. The most common source of end-organ dysfunction was MAP less than 70 mm/Hg (59%). The alert was triggered at clinical time zero in 41% of cases and within three hours in 53.6% of cases. 96% of alerts triggered before a manual nurse screen. Conclusion We are the first to report the time between a sepsis alert and physician chart-review clinical time zero. Incorporating physician orders in the alert criteria improves specificity while maintaining sensitivity, which is important to reduce alert fatigue. By leveraging standard EHR functionality, this alert could be implemented by other healthcare systems. PMID:27437061
Rolnick, Joshua; Downing, N Lance; Shepard, John; Chu, Weihan; Tam, Julia; Wessels, Alexander; Li, Ron; Dietrich, Brian; Rudy, Michael; Castaneda, Leon; Shieh, Lisa
2016-01-01
Increasing use of EHRs has generated interest in the potential of computerized clinical decision support to improve treatment of sepsis. Electronic sepsis alerts have had mixed results due to poor test characteristics, the inability to detect sepsis in a timely fashion and the use of outside software limiting widespread adoption. We describe the development, evaluation and validation of an accurate and timely severe sepsis alert with the potential to impact sepsis management. To develop, evaluate, and validate an accurate and timely severe sepsis alert embedded in a commercial EHR. The sepsis alert was developed by identifying the most common severe sepsis criteria among a cohort of patients with ICD 9 codes indicating a diagnosis of sepsis. This alert requires criteria in three categories: indicators of a systemic inflammatory response, evidence of suspected infection from physician orders, and markers of organ dysfunction. Chart review was used to evaluate test performance and the ability to detect clinical time zero, the point in time when a patient develops severe sepsis. Two physicians reviewed 100 positive cases and 75 negative cases. Based on this review, sensitivity was 74.5%, specificity was 86.0%, the positive predictive value was 50.3%, and the negative predictive value was 94.7%. The most common source of end-organ dysfunction was MAP less than 70 mm/Hg (59%). The alert was triggered at clinical time zero in 41% of cases and within three hours in 53.6% of cases. 96% of alerts triggered before a manual nurse screen. We are the first to report the time between a sepsis alert and physician chart-review clinical time zero. Incorporating physician orders in the alert criteria improves specificity while maintaining sensitivity, which is important to reduce alert fatigue. By leveraging standard EHR functionality, this alert could be implemented by other healthcare systems.
Tarai, B; Das, P; Kumar, D; Budhiraja, S
2012-01-01
Paired blood culture (PBC) is uncommon practice in hospitals in India, leading to delayed and inadequate diagnosis. Also contamination remains a critical determinant in hampering the definitive diagnosis. To establish the need of PBC over single blood culture (SBC) along with the degree of contamination, this comparative retrospective study was initiated. We processed 2553 PBC and 4350 SBC in BacT/ALERT 3D (bioMerieux) between October 2010 and June 2011. The positive cultures were identified in VITEK 2 Compact (bioMerieux). True positivity and contaminants were also analyzed in 486 samples received from catheter and peripheral line. Out of 2553 PBC samples, positivity was seen in 350 (13.70%). In 4350 SBC samples, positivity was seen in 200 samples (4.59%). In PBC true pathogens were 267 (10.45%) and contaminants were 83 (3.25%), whereas in SBC 153 (3.51%) were true positives and contaminants were 47 (1.08%). Most of the blood cultures (99.27 %) grew within 72 h and 95.8% were isolated within 48 h. In 486 PBCs received from catheter/periphery (one each), catheter positivity was found in 85 (true positives were 48, false positives 37). In peripheral samples true positives were 50 and false positives were 8. Significantly higher positive rates were seen in PBCs compared with SBCs. Automated blood culture and identification methods significantly reduced the time required for processing of samples and also facilitated yield of diverse/rare organisms. Blood culture from catheter line had higher false positives than peripheral blood culture. Thus every positive result from a catheter must be correlated with clinical findings and requires further confirmation.
Rapid deployable global sensing hazard alert system
Cordaro, Joseph V; Tibrea, Steven L; Shull, Davis J; Coleman, Jerry T; Shuler, James M
2015-04-28
A rapid deployable global sensing hazard alert system and associated methods of operation are provided. An exemplary system includes a central command, a wireless backhaul network, and a remote monitoring unit. The remote monitoring unit can include a positioning system configured to determine a position of the remote monitoring unit based on one or more signals received from one or more satellites located in Low Earth Orbit. The wireless backhaul network can provide bidirectional communication capability independent of cellular telecommunication networks and the Internet. An exemplary method includes instructing at least one of a plurality of remote monitoring units to provide an alert based at least in part on a location of a hazard and a plurality of positions respectively associated with the plurality of remote monitoring units.
[Sequential monitoring of renal transplant with aspiration cytology].
Manfro, R C; Gonçalves, L F; de Moura, L A
1998-01-01
To evaluate the utility of kidney aspiration cytology in the sequential monitorization of acute rejection in renal transplant patients. Thirty patients were submitted to 376 aspirations. The clinical diagnoses were independently established. The representativity of the samples reached 82.7%. The total corrected increment index and the number of immunoactivated cells were higher during acute rejection as compared to normal allograft function, acute tubular necrosis, and cyclosporine nephrotoxicity. The parameters to the diagnosis of acute rejection were sensitivity: 71.8%, specificity: 87.3%, positive predictive value: 50.9%, negative predictive value: 94.9% and accuracy 84.9%. The false positive results were mainly related to cytomegalovirus infection or to the administration of OKT3. In 10 out of 11 false negative results incipient immunoactivation was present alerting to the possibility of acute rejection. Kidney aspiration cytology is a useful tool for the sequential monitorization of acute rejection in renal transplant patients. The best results are reached when the results of aspiration cytology are analyzed with the clinical data.
An Analysis of EMS and ED Detection of Stroke.
Medoro, Ian; Cone, David C
2017-01-01
Studies have shown a reduction in time-to-CT and improved process measures when EMS personnel notify the ED of a "stroke alert" from the field. However, there are few data on the accuracy of these EMS stroke alerts. The goal of this study was to examine diagnostic test performance of EMS and ED stroke alerts and related process measures. The EMS and ED records of all stroke alerts in a large tertiary ED from August 2013-January 2014 were examined and data abstracted by one trained investigator, with data accuracy confirmed by a second investigator for 15% of cases. Stroke alerts called by EMS prior to ED arrival were compared to stroke alerts called by ED physicians and nurses (for walk-in patients, and patients transported by EMS without EMS stroke alerts). Means ± SD, medians, unpaired t-tests (for continuous data), and two-tailed Fisher's exact tests (for categorical data) were used. Of 260 consecutive stroke alerts, 129 were EMS stroke alerts, and 131 were ED stroke alerts (70 called by physicians, 61 by nurses). The mean NIH Stroke Scale was higher in the EMS group (8.1 ± 7.6 vs. 3.0 ± 5.0, p < 0.0001). The positive predictive value of EMS stroke alerts was 0.60 (78/129), alerts by ED nurses was 0.25 (15/61), and alerts by ED physicians was 0.31 (22/70). The PPV for EMS was better than for nurses or physicians (both p < 0.001), and more patients in the EMS group had final diagnoses of stroke (62/129 vs. 24/131, p < 0.001). The positive likelihood ratio was 1.53 for EMS personnel, 0.45 for physicians, and 0.77 for nurses. The mean time to order the CT (8.5 ± 7.1 min vs. 23.1 ± 18.2 min, p < 0.0001) and the mean ED length of stay (248 ± 116 min vs. 283 ± 128 min, p = 0.022) were shorter for the EMS stroke alert group. More EMS stroke alert patients received tPA (16/129 vs. 6/131, p = 0.027). EMS stroke alerts have better diagnostic test performance than stroke alerts by ED staff, likely due to higher NIH Stroke Scale scores (more obvious presentations) and are associated with better process measures. The fairly low PPV suggests room for improvement in prehospital stroke protocols.
Validation of a personal fluid loss monitor.
Wickwire, J; Bishop, P A; Green, J M; Richardson, M T; Lomax, R G; Casaru, C; Jones, E; Curtner-Smith, M
2008-02-01
Dehydration raises heat injury risk and reduces performance [ , , ]. The purpose was to validate the Hydra-Alert Jr (Acumen). The Hydra-Alert was tested in two exercise/clothing conditions. Participants wore it while wearing exercise clothing and exercising at a self-selected intensity (n = 8). Others wore the Hydra-Alert while wearing a ballistic-vest and performing an industrial-protocol (n = 8). For each condition, the Hydra-Alert was tested on two occasions (T1 and T2). The Hydra-Alert was tested against nude weight loss for both conditions. The Hydra-Alert had low test-retest reliability for both conditions (average absolute value of the error between Hydra-Alert outputs of T1 and T2 = 0.08 +/- 0.08 percentage points). With exercise-clothing, the Hydra-Alert evidenced low-moderate correlations between percent nude weight loss and Hydra-Alert output at 20 min (r = 0.59-T1, p = 0.13; r = 0.12-T2, p = 0.78), at 40 min (r = 0.93-T1, p = 0.001; r = 0.63-T2, p = 0.10), and at approximately 2 % weight loss (r = 0.21-T1 and T2, p = 0.61 and 0.62, respectively). The correlation at 40 min during T1 fell during T2 suggesting the Hydra-Alert was inconsistent. When wearing a ballistic-vest, the Hydra-Alert had poor validity (T1: r = - 0.29 [p = 0.48] for weight loss vs. monitor; T2: r = 0.11 [p = 0.80]). At the higher levels of dehydration ( approximately 2 %), the Hydra-Alert error was so high as to render its readings of little value. In some cases, the Hydra-Alert could lead to a false level of security if dehydrated. Therefore, the Hydra-Alert is of little use for those who want to measure their fluid loss while exercising in the heat.
Computerized Alerts Improve Outpatient Laboratory Monitoring of Transplant Patients
Staes, Catherine J.; Evans, R. Scott; Rocha, Beatriz H.S.C.; Sorensen, John B.; Huff, Stanley M.; Arata, Joan; Narus, Scott P.
2008-01-01
Authors evaluated the impact of computerized alerts on the quality of outpatient laboratory monitoring for transplant patients. For 356 outpatient liver transplant patients managed at LDS Hospital, Salt Lake City, this observational study compared traditional laboratory result reporting, using faxes and printouts, to computerized alerts implemented in 2004. Study alerts within the electronic health record notified clinicians of new results and overdue new orders for creatinine tests and immunosuppression drug levels. After implementing alerts, completeness of reporting increased from 66 to >99 %, as did positive predictive value that a report included new information (from 46 to >99 %). Timeliness of reporting and clinicians' responses improved after implementing alerts (p <0.001): median times for clinicians to receive and complete actions decreased to 9 hours from 33 hours using the prior traditional reporting system. Computerized alerts led to more efficient, complete, and timely management of laboratory information. PMID:18308982
Aircraft Conflict Analysis and Real-Time Conflict Probing Using Probabilistic Trajectory Modeling
NASA Technical Reports Server (NTRS)
Yang, Lee C.; Kuchar, James K.
2000-01-01
Methods for maintaining separation between aircraft in the current airspace system have been built from a foundation of structured routes and evolved procedures. However, as the airspace becomes more congested and the chance of failures or operational error become more problematic, automated conflict alerting systems have been proposed to help provide decision support and to serve as traffic monitoring aids. The problem of conflict detection and resolution has been tackled from a number of different ways, but in this thesis, it is recast as a problem of prediction in the presence of uncertainties. Much of the focus is concentrated on the errors and uncertainties from the working trajectory model used to estimate future aircraft positions. The more accurate the prediction, the more likely an ideal (no false alarms, no missed detections) alerting system can be designed. Additional insights into the problem were brought forth by a review of current operational and developmental approaches found in the literature. An iterative, trial and error approach to threshold design was identified. When examined from a probabilistic perspective, the threshold parameters were found to be a surrogate to probabilistic performance measures. To overcome the limitations in the current iterative design method, a new direct approach is presented where the performance measures are directly computed and used to perform the alerting decisions. The methodology is shown to handle complex encounter situations (3-D, multi-aircraft, multi-intent, with uncertainties) with relative ease. Utilizing a Monte Carlo approach, a method was devised to perform the probabilistic computations in near realtime. Not only does this greatly increase the method's potential as an analytical tool, but it also opens up the possibility for use as a real-time conflict alerting probe. A prototype alerting logic was developed and has been utilized in several NASA Ames Research Center experimental studies.
The effect of phasic auditory alerting on visual perception.
Petersen, Anders; Petersen, Annemarie Hilkjær; Bundesen, Claus; Vangkilde, Signe; Habekost, Thomas
2017-08-01
Phasic alertness refers to a short-lived change in the preparatory state of the cognitive system following an alerting signal. In the present study, we examined the effect of phasic auditory alerting on distinct perceptual processes, unconfounded by motor components. We combined an alerting/no-alerting design with a pure accuracy-based single-letter recognition task. Computational modeling based on Bundesen's Theory of Visual Attention was used to examine the effect of phasic alertness on visual processing speed and threshold of conscious perception. Results show that phasic auditory alertness affects visual perception by increasing the visual processing speed and lowering the threshold of conscious perception (Experiment 1). By manipulating the intensity of the alerting cue, we further observed a positive relationship between alerting intensity and processing speed, which was not seen for the threshold of conscious perception (Experiment 2). This was replicated in a third experiment, in which pupil size was measured as a physiological marker of alertness. Results revealed that the increase in processing speed was accompanied by an increase in pupil size, substantiating the link between alertness and processing speed (Experiment 3). The implications of these results are discussed in relation to a newly developed mathematical model of the relationship between levels of alertness and the speed with which humans process visual information. Copyright © 2017 Elsevier B.V. All rights reserved.
Campmans, Zizi; van Rhijn, Arianne; Dull, René M; Santen-Reestman, Jacqueline; Taxis, Katja; Borgsteede, Sander D
2018-01-01
Drug confusion is thought to be the most common type of dispensing error. Several strategies can be implemented to reduce the risk of medication errors. One of these are alerts in the pharmacy information system. To evaluate the experiences of pharmacists and pharmacy technicians with alerts for drug name and strength confusion. In May 2017, a cross-sectional survey of pharmacists and pharmacy technicians was performed in community pharmacies in the Netherlands using an online questionnaire. Of the 269 respondents, 86% (n = 230) had noticed the alert for drug name confusion, and 26% (n = 67) for drug strength confusion. Of those 230, 9% (n = 20) had experienced that the alert had prevented dispensing the wrong drug. For drug strength confusion, this proportion was 12% (n = 8). Respondents preferred to have an alert for drug name and strength confusion in the pharmacy information system. 'Alert fatigue' was an important issue, so alerts should only be introduced for frequent confusions or confusions with serious consequences. Pharmacists and pharmacy technicians were positive about having alerts for drug confusions in their pharmacy information system and experienced that alerts contributed to the prevention of dispensing errors. To prevent alert fatigue, it was considered important not to include all possible confusions as a new alert: the potential contribution to the prevention of drug confusion should be weighed against the risk of alert fatigue.
JPL's GNSS Real-Time Earthquake and Tsunami (GREAT) Alert System
NASA Astrophysics Data System (ADS)
Bar-Sever, Yoaz; Miller, Mark; Vallisneri, Michele; Khachikyan, Robert; Meyer, Robert
2017-04-01
We describe recent developments to the GREAT Alert natural hazard monitoring service from JPL's Global Differential GPS (GDGPS) System. GREAT Alert provides real-time, 1 Hz positioning solutions for hundreds of GNSS tracking sites, from both global and regional networks, aiming to monitor ground motion in the immediate aftermath of earthquakes. We take advantage of the centralized data processing, which is collocated with the GNSS orbit determination operations of the GDGPS System, to combine orbit determination with large-scale point-positioning in a grand estimation scheme, and as a result realize significant improvement to the positioning accuracy compared to conventional stand-alone point positioning techniques. For example, the measured median site (over all sites) real-time horizontal positioning accuracy is 2 cm 1DRMS, and the median real-time vertical accuracy is 4 cm RMS. The GREAT Alert positioning service is integrated with automated global earthquake notices from the United States Geodetic Survey (USGS) to support near-real-time calculations of co-seismic displacements with attendant formal errors based both short-term and long-term error analysis for each individual site. We will show the millimeter-level resolution of co-seismic displacement can be achieved by this system. The co-seismic displacements, in turn, are fed into a JPL geodynamics and ocean models, that estimate the Earthquake magnitude and predict the potential tsunami scale.
Austrian, Jonathan S; Adelman, Jason S; Reissman, Stan H; Cohen, Hillel W; Billett, Henny H
2011-01-01
The aim of this study was to measure the effect of an electronic heparin-induced thrombocytopenia (HIT) alert on provider ordering behaviors and on patient outcomes. A pop-up alert was created for providers when an individual's platelet values had decreased by 50% or to <100,000/mm(3) in the setting of recent heparin exposure. The authors retrospectively compared inpatients admitted between January 24, 2008 and August 24, 2008 to a control group admitted 1 year prior to the HIT alert. The primary outcome was a change in HIT antibody testing. Secondary outcomes included an assessment of incidence of HIT antibody positivity, percentage of patients started on a direct thrombin inhibitor (DTI), length of stay and overall mortality. There were 1006 and 1081 patients in the control and intervention groups, respectively. There was a 33% relative increase in HIT antibody test orders (p=0.01), and 33% more of these tests were ordered the first day after the criteria were met when a pop-up alert was given (p=0.03). Heparin was discontinued in 25% more patients in the alerted group (p=0.01), and more direct thrombin inhibitors were ordered for them (p=0.03). The number who tested HIT antibody-positive did not differ, however, between the two groups (p=0.99). The length of stay and mortality were similar in both groups. The HIT alert significantly impacted provider behaviors. However, the alert did not result in more cases of HIT being detected or an improvement in overall mortality. Our findings do not support implementation of a computerized HIT alert.
Marcelino, Isabel; Lopes, David; Reis, Michael; Silva, Fernando; Laza, Rosalía; Pereira, António
2015-01-01
World's aging population is rising and the elderly are increasingly isolated socially and geographically. As a consequence, in many situations, they need assistance that is not granted in time. In this paper, we present a solution that follows the CRISP-DM methodology to detect the elderly's behavior pattern deviations that may indicate possible risk situations. To obtain these patterns, many variables are aggregated to ensure the alert system reliability and minimize eventual false positive alert situations. These variables comprehend information provided by body area network (BAN), by environment sensors, and also by the elderly's interaction in a service provider platform, called eServices--Elderly Support Service Platform. eServices is a scalable platform aggregating a service ecosystem developed specially for elderly people. This pattern recognition will further activate the adequate response. With the system evolution, it will learn to predict potential danger situations for a specified user, acting preventively and ensuring the elderly's safety and well-being. As the eServices platform is still in development, synthetic data, based on real data sample and empiric knowledge, is being used to populate the initial dataset. The presented work is a proof of concept of knowledge extraction using the eServices platform information. Regardless of not using real data, this work proves to be an asset, achieving a good performance in preventing alert situations.
Marcelino, Isabel; Laza, Rosalía
2015-01-01
World's aging population is rising and the elderly are increasingly isolated socially and geographically. As a consequence, in many situations, they need assistance that is not granted in time. In this paper, we present a solution that follows the CRISP-DM methodology to detect the elderly's behavior pattern deviations that may indicate possible risk situations. To obtain these patterns, many variables are aggregated to ensure the alert system reliability and minimize eventual false positive alert situations. These variables comprehend information provided by body area network (BAN), by environment sensors, and also by the elderly's interaction in a service provider platform, called eServices—Elderly Support Service Platform. eServices is a scalable platform aggregating a service ecosystem developed specially for elderly people. This pattern recognition will further activate the adequate response. With the system evolution, it will learn to predict potential danger situations for a specified user, acting preventively and ensuring the elderly's safety and well-being. As the eServices platform is still in development, synthetic data, based on real data sample and empiric knowledge, is being used to populate the initial dataset. The presented work is a proof of concept of knowledge extraction using the eServices platform information. Regardless of not using real data, this work proves to be an asset, achieving a good performance in preventing alert situations. PMID:25874219
A Cross-Reactivity of Fenofibric Acid With MDMA DRI Assay.
Bugier, Sarah; Garcia-Hejl, Carine; Vest, Philippe; Plantamura, Julie; Chianea, Denis; Renard, Christophe
2016-09-01
Within the framework of routine fitness examinations, French Air Force military crew underwent urine testing for 3,4 methylenedioxymetamphetamine (MDMA [ecstasy]). The cross-reactivity of a dyslipidemic drug, fenofibrate, with an MDMA immunoassay was studied and confirmed on a large population sample. A 3-year retrospective study was performed on the MDMA DRI Ecstasy Assay on the Unicel DXC 600. In the event of positive test result, a confirmatory testing was carried out by gas chromatography/mass spectrometry (GC/MS) to establish the presence of MDMA. When analysis by GC/MS did not confirm the presence of MDMA, a false-positive result was suspected and the samples were analyzed by high-performance liquid chromatography-mass spectrometry to identify a potential interfering substance. A total of 15,169 urine samples, from 7,803 patients, were tested for 3 years. Of the tested samples, 22 (0.15%) were positive by DRI Ecstasy Assay. None of them were positive by GC/MS. A cross-reactivity of fenofibrate's metabolite with MDMA using this assay was systematically found. Fenofibrate's interference with MDMA immunoassay was confirmed. Fenofibrate being widely prescribed, physicians had to be alerted that this treatment could lead to false-positive results. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
Crum, Alia J.; Phillips, Damon J.; Goyer, J. Parker; Akinola, Modupe; Higgins, E. Tory
2016-01-01
This paper investigates how social influence can alter physiological, psychological, and functional responses to a placebo product and how such responses influence the ultimate endorsement of the product. Participants consumed a product, “AquaCharge Energy Water,” falsely-labeled as containing 200 mg of caffeine but which was actually plain spring water, in one of three conditions: a no social influence condition, a disconfirming social influence condition, and a confirming social influence condition. Results demonstrated that the effect of the product labeling on physiological alertness (systolic blood pressure), psychological alertness (self-reported alertness), functional alertness (cognitive interference), and product endorsement was moderated by social influence: participants experienced more subjective, physiological and functional alertness and stronger product endorsement when they consumed the product in the confirming social influence condition than when they consumed the product in the disconfirming social influence condition. These results suggest that social influence can alter subjective, physiological, and functional responses to a faux product, in this case transforming the effects of plain water. PMID:27875567
Crum, Alia J; Phillips, Damon J; Goyer, J Parker; Akinola, Modupe; Higgins, E Tory
2016-01-01
This paper investigates how social influence can alter physiological, psychological, and functional responses to a placebo product and how such responses influence the ultimate endorsement of the product. Participants consumed a product, "AquaCharge Energy Water," falsely-labeled as containing 200 mg of caffeine but which was actually plain spring water, in one of three conditions: a no social influence condition, a disconfirming social influence condition, and a confirming social influence condition. Results demonstrated that the effect of the product labeling on physiological alertness (systolic blood pressure), psychological alertness (self-reported alertness), functional alertness (cognitive interference), and product endorsement was moderated by social influence: participants experienced more subjective, physiological and functional alertness and stronger product endorsement when they consumed the product in the confirming social influence condition than when they consumed the product in the disconfirming social influence condition. These results suggest that social influence can alter subjective, physiological, and functional responses to a faux product, in this case transforming the effects of plain water.
Safe and sound? A systematic literature review of seizure detection methods for personal use.
Jory, Caryn; Shankar, Rohit; Coker, Deborah; McLean, Brendan; Hanna, Jane; Newman, Craig
2016-03-01
The study aims to review systematically the quality of evidence supporting seizure detection devices. The unpredictable nature of seizures is distressing and disabling for sufferers and carers. If a seizure can be reliably detected then the patient or carer could be alerted. It could help prevent injury and death. A literature search was completed. Forty three of 120 studies found using relevant search terms were suitable for systematic review which was done applying pre-agreed criteria using PRISMA guidelines. The papers identified and reviewed were those that could have potential for everyday use of patients in a domestic setting. Studies involving long term use of scalp electrodes to record EEG were excluded on the grounds of unacceptable restriction of daily activities. Most of the devices focused on changes in movement and/or physiological signs and were dependent on an algorithm to determine cut off points. No device was able to detect all seizures and there was an issue with both false positives and missed seizures. Many of the studies involved relatively small numbers of cases or report on only a few seizures. Reports of seizure alert dogs are also considered. Seizure detection devices are at a relatively early stage of development and as yet there are no large scale studies or studies that compare the effectiveness of one device against others. The issue of false positive detection rates is important as they are disruptive for both the patient and the carer. Nevertheless, the development of seizure detection devices offers great potential in the management of epilepsy. Copyright © 2016 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
Seidling, Hanna M; Phansalkar, Shobha; Seger, Diane L; Paterno, Marilyn D; Shaykevich, Shimon; Haefeli, Walter E
2011-01-01
Background Clinical decision support systems can prevent knowledge-based prescription errors and improve patient outcomes. The clinical effectiveness of these systems, however, is substantially limited by poor user acceptance of presented warnings. To enhance alert acceptance it may be useful to quantify the impact of potential modulators of acceptance. Methods We built a logistic regression model to predict alert acceptance of drug–drug interaction (DDI) alerts in three different settings. Ten variables from the clinical and human factors literature were evaluated as potential modulators of provider alert acceptance. ORs were calculated for the impact of knowledge quality, alert display, textual information, prioritization, setting, patient age, dose-dependent toxicity, alert frequency, alert level, and required acknowledgment on acceptance of the DDI alert. Results 50 788 DDI alerts were analyzed. Providers accepted only 1.4% of non-interruptive alerts. For interruptive alerts, user acceptance positively correlated with frequency of the alert (OR 1.30, 95% CI 1.23 to 1.38), quality of display (4.75, 3.87 to 5.84), and alert level (1.74, 1.63 to 1.86). Alert acceptance was higher in inpatients (2.63, 2.32 to 2.97) and for drugs with dose-dependent toxicity (1.13, 1.07 to 1.21). The textual information influenced the mode of reaction and providers were more likely to modify the prescription if the message contained detailed advice on how to manage the DDI. Conclusion We evaluated potential modulators of alert acceptance by assessing content and human factors issues, and quantified the impact of a number of specific factors which influence alert acceptance. This information may help improve clinical decision support systems design. PMID:21571746
Improved Conflict Detection for Reducing Operational Errors in Air Traffic Control
NASA Technical Reports Server (NTRS)
Paielli, Russell A.; Erzberger, Hainz
2003-01-01
An operational error is an incident in which an air traffic controller allows the separation between two aircraft to fall below the minimum separation standard. The rates of such errors in the US have increased significantly over the past few years. This paper proposes new detection methods that can help correct this trend by improving on the performance of Conflict Alert, the existing software in the Host Computer System that is intended to detect and warn controllers of imminent conflicts. In addition to the usual trajectory based on the flight plan, a "dead-reckoning" trajectory (current velocity projection) is also generated for each aircraft and checked for conflicts. Filters for reducing common types of false alerts were implemented. The new detection methods were tested in three different ways. First, a simple flightpath command language was developed t o generate precisely controlled encounters for the purpose of testing the detection software. Second, written reports and tracking data were obtained for actual operational errors that occurred in the field, and these were "replayed" to test the new detection algorithms. Finally, the detection methods were used to shadow live traffic, and performance was analysed, particularly with regard to the false-alert rate. The results indicate that the new detection methods can provide timely warnings of imminent conflicts more consistently than Conflict Alert.
McDonald, C P; Rogers, A; Cox, M; Smith, R; Roy, A; Robbins, S; Hartley, S; Barbara, J A J; Rothenberg, S; Stutzman, L; Widders, G
2002-10-01
Bacterial transmission remains the major component of morbidity and mortality associated with transfusion-transmitted infections. Platelet concentrates are the most common cause of bacterial transmission. The BacT/ALERT 3D automated blood culture system has the potential to screen platelet concentrates for the presence of bacteria. Evaluation of this system was performed by spiking day 2 apheresis platelet units with individual bacterial isolates at final concentrations of 10 and 100 colony-forming units (cfu) mL-1. Fifteen organisms were used which had been cited in platelet transmission and monitoring studies. BacT/ALERT times to detection were compared with thioglycollate broth cultures, and the performance of five types of BacT/ALERT culture bottles was evaluated. Sampling was performed immediately after the inoculation of the units, and 10 replicates were performed per organism concentration for each of the five types of BacT/ALERT bottles. The mean times for the detection of these 15 organisms by BacT/ALERT, with the exception of Propionibacterium acnes, ranged from 9.1 to 48.1 h (all 10 replicates were positive). In comparison, the time range found using thioglycollate was 12.0-32.3 h (all 10 replicates were positive). P. acnes' BacT/ALERT mean detection times ranged from 89.0 to 177.6 h compared with 75.6-86.4 h for the thioglycollate broth. BacT/ALERT, with the exception of P. acnes, which has dubious clinical significance, gave equivalent or shorter detection times when compared with the thioglycollate broth system. The BacT/ALERT system detected a range of organisms at levels of 10 and 100 cfu mL-1. This study validates the BacT/ALERT microbial detection system for screening platelets. Currently, the system is the only practically viable option available for routinely screening platelet concentrates to prevent bacterial transmission.
Campmans, Zizi; van Rhijn, Arianne; Dull, René M.; Santen-Reestman, Jacqueline; Taxis, Katja
2018-01-01
Introduction Drug confusion is thought to be the most common type of dispensing error. Several strategies can be implemented to reduce the risk of medication errors. One of these are alerts in the pharmacy information system. Objective To evaluate the experiences of pharmacists and pharmacy technicians with alerts for drug name and strength confusion. Methods In May 2017, a cross-sectional survey of pharmacists and pharmacy technicians was performed in community pharmacies in the Netherlands using an online questionnaire. Results Of the 269 respondents, 86% (n = 230) had noticed the alert for drug name confusion, and 26% (n = 67) for drug strength confusion. Of those 230, 9% (n = 20) had experienced that the alert had prevented dispensing the wrong drug. For drug strength confusion, this proportion was 12% (n = 8). Respondents preferred to have an alert for drug name and strength confusion in the pharmacy information system. ‘Alert fatigue’ was an important issue, so alerts should only be introduced for frequent confusions or confusions with serious consequences. Conclusion Pharmacists and pharmacy technicians were positive about having alerts for drug confusions in their pharmacy information system and experienced that alerts contributed to the prevention of dispensing errors. To prevent alert fatigue, it was considered important not to include all possible confusions as a new alert: the potential contribution to the prevention of drug confusion should be weighed against the risk of alert fatigue. PMID:29813099
Point Positioning Service for Natural Hazard Monitoring
NASA Astrophysics Data System (ADS)
Bar-Sever, Y. E.
2014-12-01
In an effort to improve natural hazard monitoring, JPL has invested in updating and enlarging its global real-time GNSS tracking network, and has launched a unique service - real-time precise positioning for natural hazard monitoring, entitled GREAT Alert (GNSS Real-Time Earthquake and Tsunami Alert). GREAT Alert leverages the full technological and operational capability of the JPL's Global Differential GPS System [www.gdgps.net] to offer owners of real-time dual-frequency GNSS receivers: Sub-5 cm (3D RMS) real-time, absolute positioning in ITRF08, regardless of location Under 5 seconds turnaround time Full covariance information Estimates of ancillary parameters (such as troposphere) optionally provided This service enables GNSS networks operators to instantly have access to the most accurate and reliable real-time positioning solutions for their sites, and also to the hundreds of participating sites globally, assuring inter-consistency and uniformity across all solutions. Local authorities with limited technical and financial resources can now access to the best technology, and share environmental data to the benefit of the entire pacific region. We will describe the specialized precise point positioning techniques employed by the GREAT Alert service optimized for natural hazard monitoring, and in particular Earthquake monitoring. We address three fundamental aspects of these applications: 1) small and infrequent motion, 2) the availability of data at a central location, and 3) the need for refined solutions at several time scales
On-Board GPS Clock Monitoring for Signal Integrity
2010-11-01
to-alert requirements to permit primary reliance for safety -of-life applications. Augmentation systems are being developed and deployed to address...virtually no false alerts from the combined system . With three running, on-board AFSs , occasional breaks of the error threshold can be allowed if the... system can be assured of transfer to another AFS within a period shorter than the required TTA. With only two AFSs on board running and measured
Heideman, Wieke H; de Wit, Maartje; Middelkoop, Barend J C; Nierkens, Vera; Stronks, Karien; Verhoeff, Arnoud P; Snoek, Frank J
2012-09-27
Prevalence of type 2 diabetes mellitus is increasing due to lifestyle changes, particularly affecting those genetically at risk. We developed DiAlert as a targeted group-based intervention aimed to promote intrinsic motivation and action planning for lifestyle changes and weight loss in first degree relatives of patients with type 2 diabetes mellitus.The main objective of the pilot of the DiAlert intervention was to assess fidelity, feasibility and acceptability prior to starting the randomized controlled trial. Individuals with a family history of type 2 diabetes mellitus were self-identified and screened for eligibility. DiAlert consists of two group sessions. Feasibility, fidelity, acceptability and self-reported perceptions and behavioral determinants were evaluated in a pre-post study using questionnaires and observations. Determinants of behavior change were analyzed using paired-samples t tests and Wilcoxon signed rank tests. DiAlert was delivered to two groups of first degree relatives of patients with type 2 diabetes mellitus (N = 9 and N = 12). Feasibility and fidelity were confirmed. Overall, the DiAlert group sessions were positively evaluated (8.0 on a scale of 1 to 10) by participants. The intervention did not impact perceived susceptibility or worry about personal diabetes risk. Action planning with regard to changing diet and physical activity increased. DiAlert proved feasible and was well-accepted by participants. Positive trends in action planning indicate increased likelihood of actual behavior change following DiAlert. Testing the effectiveness in a randomized controlled trial is imperative. Netherlands National Trial Register (NTR): NTR2036.
Comparison of Two Sepsis Recognition Methods in a Pediatric Emergency Department
Balamuth, Fran; Alpern, Elizabeth R.; Grundmeier, Robert W.; Chilutti, Marianne; Weiss, Scott L.; Fitzgerald, Julie C.; Hayes, Katie; Bilker, Warren; Lautenbach, Ebbing
2015-01-01
Objectives To compare the effectiveness of physician judgment and an electronic algorithmic alert to identify pediatric patients with severe sepsis/septic shock in a pediatric emergency department (ED). Methods This was an observational cohort study of patients older than 56 days with fever or hypothermia. All patients were evaluated for potential sepsis in real time by the ED clinical team. An electronic algorithmic alert was retrospectively applied to identify patients with potential sepsis independent of physician judgment. The primary outcome was the proportion of patients correctly identified with severe sepsis/septic shock defined by consensus criteria. Test characteristics were determined and receiver operating characteristic (ROC) curves were compared. Results Of 19,524 eligible patient visits, 88 patients developed consensus-confirmed severe sepsis or septic shock. Physician judgment identified 159, and the algorithmic alert identified 3,301 patients with potential sepsis. Physician judgment had sensitivity of 72.7% (95% CI = 72.1% to 73.4%) and specificity 99.5% (95% CI = 99.4% to 99.6%); the algorithmic alert had sensitivity 92.1% (95% CI = 91.7% to 92.4%), and specificity 83.4% (95% CI = 82.9% to 83.9%) for severe sepsis/septic shock. There was no significant difference in the area under the ROC curve for physician judgment (0.86, 95% CI = 0.81 to 0.91) or the algorithm (0.88, 95% CI = 0.85 to 0.91; p = 0.54). A combination method using either positive physician judgment or an algorithmic alert improved sensitivity to 96.6% and specificity to 83.3%. A sequential approach, in which positive identification by the algorithmic alert was then confirmed by physician judgment, achieved 68.2% sensitivity and 99.6% specificity. Positive and negative predictive values for physician judgment vs. algorithmic alert were 40.3% vs. 2.5% and 99.88 % vs. 99.96%, respectively. Conclusions The electronic algorithmic alert was more sensitive but less specific than physician judgment for recognition of pediatric severe sepsis and septic shock. These findings can help to guide institutions in selecting pediatric sepsis recognition methods based on institutional needs and priorities. PMID:26474032
Comparison of Two Sepsis Recognition Methods in a Pediatric Emergency Department.
Balamuth, Fran; Alpern, Elizabeth R; Grundmeier, Robert W; Chilutti, Marianne; Weiss, Scott L; Fitzgerald, Julie C; Hayes, Katie; Bilker, Warren; Lautenbach, Ebbing
2015-11-01
The objective was to compare the effectiveness of physician judgment and an electronic algorithmic alert to identify pediatric patients with severe sepsis/septic shock in a pediatric emergency department (ED). This was an observational cohort study of patients older than 56 days with fever or hypothermia. All patients were evaluated for potential sepsis in real time by the ED clinical team. An electronic algorithmic alert was retrospectively applied to identify patients with potential sepsis independent of physician judgment. The primary outcome was the proportion of patients correctly identified with severe sepsis/septic shock defined by consensus criteria. Test characteristics were determined and receiver operating characteristic (ROC) curves were compared. Of 19,524 eligible patient visits, 88 patients developed consensus-confirmed severe sepsis or septic shock. Physician judgment identified 159 and the algorithmic alert identified 3,301 patients with potential sepsis. Physician judgment had sensitivity of 72.7% (95% confidence interval [CI] = 72.1% to 73.4%) and specificity of 99.5% (95% CI = 99.4% to 99.6%); the algorithmic alert had sensitivity of 92.1% (95% CI = 91.7% to 92.4%) and specificity of 83.4% (95% CI = 82.9% to 83.9%) for severe sepsis/septic shock. There was no significant difference in the area under the ROC curve for physician judgment (0.86, 95% CI = 0.81 to 0.91) or the algorithm (0.88, 95% CI = 0.85 to 0.91; p = 0.54). A combination method using either positive physician judgment or an algorithmic alert improved sensitivity to 96.6% and specificity to 83.3%. A sequential approach, in which positive identification by the algorithmic alert was then confirmed by physician judgment, achieved 68.2% sensitivity and 99.6% specificity. Positive and negative predictive values for physician judgment versus algorithmic alert were 40.3% versus 2.5% and 99.88% versus 99.96%, respectively. The electronic algorithmic alert was more sensitive but less specific than physician judgment for recognition of pediatric severe sepsis and septic shock. These findings can help to guide institutions in selecting pediatric sepsis recognition methods based on institutional needs and priorities. © 2015 by the Society for Academic Emergency Medicine.
FAB (Functionally Alert Behavior Strategies) to Improve Self-Control
ERIC Educational Resources Information Center
Pagano, John
2015-01-01
This paper describes the FAB (Functionally Alert Behavior) Strategies approach to improve behavior in children and adolescents with complex behavioral challenges. FAB Strategies include evidence-based environmental adaptations, sensory modulation, positive behavioral support, and physical self-regulation strategies. FAB Strategies can be used by…
Xu, Xidong; Wickens, Christopher D; Rantanen, Esa M
2007-01-15
A total of 24 pilots viewed dynamic encounters between their own aircraft and an intruder aircraft on a 2-D cockpit display of traffic information (CDTI) and estimated the point and time of closest approach. A three-level alerting system provided a correct categorical estimate of the projected miss distance on 83% of the trials. The remaining 17% of alerts were equally divided between misses and false alarms, of large and small magnitude. Roughly half the pilots depended on automation to improve estimation of miss distance relative to the baseline pilots, who viewed identical trials without the aid of automated alerts. Moreover, they did so more on the more difficult traffic trials resulting in improved performance on the 83% correct automation trials without causing harm on the 17% automation-error trials, compared to the baseline group. The automated alerts appeared to lead pilots to inspect the raw data more closely. While assisting the accurate prediction of miss distance, the automation led to an underestimate of the time remaining until the point of closest approach. The results point to the benefits of even imperfect automation in the strategic alerts characteristic of the CDTI, at least as long as this reliability remains high (above 80%).
Role of data aggregation in biosurveillance detection strategies with applications from ESSENCE.
Burkom, Howard S; Elbert, Y; Feldman, A; Lin, J
2004-09-24
Syndromic surveillance systems are used to monitor daily electronic data streams for anomalous counts of features of varying specificity. The monitored quantities might be counts of clinical diagnoses, sales of over-the-counter influenza remedies, school absenteeism among a given age group, and so forth. Basic data-aggregation decisions for these systems include determining which records to count and how to group them in space and time. This paper discusses the application of spatial and temporal data-aggregation strategies for multiple data streams to alerting algorithms appropriate to the surveillance region and public health threat of interest. Such a strategy was applied and evaluated for a complex, authentic, multisource, multiregion environment, including >2 years of data records from a system-evaluation exercise for the Defense Advanced Research Project Agency (DARPA). Multivariate and multiple univariate statistical process control methods were adapted and applied to the DARPA data collection. Comparative parametric analyses based on temporal aggregation were used to optimize the performance of these algorithms for timely detection of a set of outbreaks identified in the data by a team of epidemiologists. The sensitivity and timeliness of the most promising detection methods were tested at empirically calculated thresholds corresponding to multiple practical false-alert rates. Even at the strictest false-alert rate, all but one of the outbreaks were detected by the best method, and the best methods achieved a 1-day median time before alert over the set of test outbreaks. These results indicate that a biosurveillance system can provide a substantial alerting-timeliness advantage over traditional public health monitoring for certain outbreaks. Comparative analyses of individual algorithm results indicate further achievable improvement in sensitivity and specificity.
Automatic recognition of coronal type II radio bursts: The ARBIS 2 method and first observations
NASA Astrophysics Data System (ADS)
Lobzin, Vasili; Cairns, Iver; Robinson, Peter; Steward, Graham; Patterson, Garth
Major space weather events such as solar flares and coronal mass ejections are usually accompa-nied by solar radio bursts, which can potentially be used for real-time space weather forecasts. Type II radio bursts are produced near the local plasma frequency and its harmonic by fast electrons accelerated by a shock wave moving through the corona and solar wind with a typi-cal speed of 1000 km s-1 . The coronal bursts have dynamic spectra with frequency gradually falling with time and durations of several minutes. We present a new method developed to de-tect type II coronal radio bursts automatically and describe its implementation in an extended Automated Radio Burst Identification System (ARBIS 2). Preliminary tests of the method with spectra obtained in 2002 show that the performance of the current implementation is quite high, ˜ 80%, while the probability of false positives is reasonably low, with one false positive per 100-200 hr for high solar activity and less than one false event per 10000 hr for low solar activity periods. The first automatically detected coronal type II radio bursts are also presented. ARBIS 2 is now operational with IPS Radio and Space Services, providing email alerts and event lists internationally.
Earthquake Early Warning: New Strategies for Seismic Hardware
NASA Astrophysics Data System (ADS)
Allardice, S.; Hill, P.
2017-12-01
Implementing Earthquake Early Warning System (EEWS) triggering algorithms into seismic networks has been a hot topic of discussion for some years now. With digitizer technology now available, such as the Güralp Minimus, with on average 40-60ms delay time (latency) from earthquake origin to issuing an alert the next step is to provide network operators with a simple interface for on board parameter calculations from a seismic station. A voting mechanism is implemented on board which mitigates the risk of false positives being communicated. Each Minimus can be configured to with a `score' from various sources i.e. Z channel on seismometer, N/S E/W channels on accelerometer and MEMS inside Minimus. If the score exceeds the set threshold then an alert is sent to the `Master Minimus'. The Master Minimus within the network will also be configured as to when the alert should be issued i.e. at least 3 stations must have triggered. Industry standard algorithms focus around the calculation of Peak Ground Acceleration (PGA), Peak Ground Velocity (PGV), Peak Ground Displacement (PGD) and C. Calculating these single station parameters on-board in order to stream only the results could help network operators with possible issues, such as restricted bandwidth. Developments on the Minimus allow these parameters to be calculated and distributed through Common Alert Protocol (CAP). CAP is the XML based data format used for exchanging and describing public warnings and emergencies. Whenever the trigger conditions are met the Minimus can send a signed UDP packet to the configured CAP receiver which can then send the alert via SMS, e-mail or CAP forwarding. Increasing network redundancy is also a consideration when developing these features, therefore the forwarding CAP message can be sent to multiple destinations. This allows for a hierarchical approach by which the single station (or network) parameters can be streamed to another Minimus, or data centre, or both, so that there is no one single point of failure. Developments on the Guralp Minimus to calculate these on board parameters which are capable of streaming single station parameters, accompanied with the ultra-low latency is the next generation of EEWS and Güralps contribution to the community.
Diversion Alert: 1-Year Evaluation Across Northern New England, 2013–2014
Desrosiers, Clare
2016-01-01
This report describes Diversion Alert, a unique online tool aimed at reducing misuse and diversion of prescription drugs, and reports the results of a 1-year evaluation of Diversion Alert’s impact in Maine. We used a quasi-experimental research design to compare survey data in Maine with those of neighboring states (New Hampshire and Vermont, 2013 and 2014). Compared with their counterparts in New Hampshire and Vermont who did not use Diversion Alert, prescribers and pharmacists in Maine who used Diversion Alert increased their communication with patients and other providers involved in their patients’ care, became aware of patients arrested for prescription drugs possession or diversion, used best practices associated with prevention or detection of addiction and diversion more frequently, and attributed positive changes in their prescribing practices to Diversion Alert. In combination with other state and federal programs, Diversion Alert may be an effective tool to help prevent the misuse of opioid medications. PMID:27880633
Loonen, A J M; Jansz, A R; Stalpers, J; Wolffs, P F G; van den Brule, A J C
2012-07-01
Matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) is a fast and reliable method for the identification of bacteria from agar media. Direct identification from positive blood cultures should decrease the time to obtaining the result. In this study, three different processing methods for the rapid direct identification of bacteria from positive blood culture bottles were compared. In total, 101 positive aerobe BacT/ALERT bottles were included in this study. Aliquots from all bottles were used for three bacterial processing methods, i.e. the commercially available Bruker's MALDI Sepsityper kit, the commercially available Molzym's MolYsis Basic5 kit and a centrifugation/washing method. In addition, the best method was used to evaluate the possibility of MALDI application after a reduced incubation time of 7 h of Staphylococcus aureus- and Escherichia coli-spiked (1,000, 100 and 10 colony-forming units [CFU]) aerobe BacT/ALERT blood cultures. Sixty-six (65%), 51 (50.5%) and 79 (78%) bottles were identified correctly at the species level when the centrifugation/washing method, MolYsis Basic 5 and Sepsityper were used, respectively. Incorrect identification was obtained in 35 (35%), 50 (49.5%) and 22 (22%) bottles, respectively. Gram-positive cocci were correctly identified in 33/52 (64%) of the cases. However, Gram-negative rods showed a correct identification in 45/47 (96%) of all bottles when the Sepsityper kit was used. Seven hours of pre-incubation of S. aureus- and E. coli-spiked aerobe BacT/ALERT blood cultures never resulted in reliable identification with MALDI-TOF MS. Sepsityper is superior for the direct identification of microorganisms from aerobe BacT/ALERT bottles. Gram-negative pathogens show better results compared to Gram-positive bacteria. Reduced incubation followed by MALDI-TOF MS did not result in faster reliable identification.
Head Rotation Detection in Marmoset Monkeys
NASA Astrophysics Data System (ADS)
Simhadri, Sravanthi
Head movement is known to have the benefit of improving the accuracy of sound localization for humans and animals. Marmoset is a small bodied New World monkey species and it has become an emerging model for studying the auditory functions. This thesis aims to detect the horizontal and vertical rotation of head movement in marmoset monkeys. Experiments were conducted in a sound-attenuated acoustic chamber. Head movement of marmoset monkey was studied under various auditory and visual stimulation conditions. With increasing complexity, these conditions are (1) idle, (2) sound-alone, (3) sound and visual signals, and (4) alert signal by opening and closing of the chamber door. All of these conditions were tested with either house light on or off. Infra-red camera with a frame rate of 90 Hz was used to capture of the head movement of monkeys. To assist the signal detection, two circular markers were attached to the top of monkey head. The data analysis used an image-based marker detection scheme. Images were processed using the Computation Vision Toolbox in Matlab. The markers and their positions were detected using blob detection techniques. Based on the frame-by-frame information of marker positions, the angular position, velocity and acceleration were extracted in horizontal and vertical planes. Adaptive Otsu Thresholding, Kalman filtering and bound setting for marker properties were used to overcome a number of challenges encountered during this analysis, such as finding image segmentation threshold, continuously tracking markers during large head movement, and false alarm detection. The results show that the blob detection method together with Kalman filtering yielded better performances than other image based techniques like optical flow and SURF features .The median of the maximal head turn in the horizontal plane was in the range of 20 to 70 degrees and the median of the maximal velocity in horizontal plane was in the range of a few hundreds of degrees per second. In comparison, the natural alert signal -- door opening and closing -- evoked the faster head turns than other stimulus conditions. These results suggest that behaviorally relevant stimulus such as alert signals evoke faster head-turn responses in marmoset monkeys.
Alertness Modulates Conflict Adaptation and Feature Integration in an Opposite Way
Chen, Jia; Huang, Xiting; Chen, Antao
2013-01-01
Previous studies show that the congruency sequence effect can result from both the conflict adaptation effect (CAE) and feature integration effect which can be observed as the repetition priming effect (RPE) and feature overlap effect (FOE) depending on different experimental conditions. Evidence from neuroimaging studies suggests that a close correlation exists between the neural mechanisms of alertness-related modulations and the congruency sequence effect. However, little is known about whether and how alertness mediates the congruency sequence effect. In Experiment 1, the Attentional Networks Test (ANT) and a modified flanker task were used to evaluate whether the alertness of the attentional functions had a correlation with the CAE and RPE. In Experimental 2, the ANT and another modified flanker task were used to investigate whether alertness of the attentional functions correlate with the CAE and FOE. In Experiment 1, through the correlative analysis, we found a significant positive correlation between alertness and the CAE, and a negative correlation between the alertness and the RPE. Moreover, a significant negative correlation existed between CAE and RPE. In Experiment 2, we found a marginally significant negative correlation between the CAE and the RPE, but the correlation between alertness and FOE, CAE and FOE was not significant. These results suggest that alertness can modulate conflict adaptation and feature integration in an opposite way. Participants at the high alerting level group may tend to use the top-down cognitive processing strategy, whereas participants at the low alerting level group tend to use the bottom-up processing strategy. PMID:24250824
Pfeiffer, Yvonne; Schwappach, David
2016-01-01
National safety alert systems publish relevant information to improve patient safety in hospitals. However, the information has to be transformed into local action to have an effect on patient safety. We studied three research questions: How do Swiss healthcare quality and risk managers (qm/rm(1)) see their own role in learning from safety alerts issued by the Swiss national voluntary reporting and analysis system? What are their attitudes towards and evaluations of the alerts, and which types of improvement actions were fostered by the safety alerts? A survey was developed and applied to Swiss healthcare risk and quality managers, with a response rate of 39 % (n=116). Descriptive statistics are presented. The qm/rm disseminate and communicate with a broad variety of professional groups about the alerts. While most respondents felt that they should know the alerts and their contents, only a part of them felt responsible for driving organizational change based on the recommendations. However, most respondents used safety alerts to back up their own patient safety goals. The alerts were evaluated positively on various dimensions such as usefulness and were considered as standards of good practice by the majority of the respondents. A range of organizational responses was applied, with disseminating information being the most common. An active role is related to using safety alerts for backing up own patient safety goals. To support an active role of qm/rm in their hospital's learning from safety alerts, appropriate organizational structures should be developed. Furthermore, they could be given special information or training to act as an information hub on the issues discussed in the alerts. Copyright © 2016. Published by Elsevier GmbH.
An evaluation of an intelligent home monitoring system.
Sixsmith, A J
2000-01-01
A trial was performed of an intelligent monitoring system which used sensors in the home to identify emergencies by detecting deviations from normal activity patterns. The field trial lasted three months. Twenty-two elderly people agreed to participate. Their ages ranged from early 60s to over 85, with two-thirds in the age range 75-84 years. They lived in four different localities within the UK--Ipswich, Northumberland, Merseyside and Nottingham. A total of 61 alerts was recorded, at a mean frequency about one alert per month per client. Of the 61 alerts generated, 46 were classified as false alerts and the other 15 as genuine, although no real emergencies occurred during the study. Many people in the field trial reported enhanced feelings of safety and security, which could help to stimulate independence and help them to remain living in their own homes. The monitoring system increased the care choices available to elderly people and supported and enhanced the carer's role.
Intense illumination in the morning hours improved mood and alertness but not mental performance.
Leichtfried, Veronika; Mair-Raggautz, Maria; Schaeffer, Viktoria; Hammerer-Lercher, Angelika; Mair, Gerald; Bartenbach, Christian; Canazei, Markus; Schobersberger, Wolfgang
2015-01-01
Cognitive performance and alertness are two determinants for work efficiency, varying throughout the day and depending on bright light. We conducted a prospective crossover study evaluating the impacts of exposure to an intense, early morning illumination on sustained attention, alertness, mood, and serum melatonin levels in 33 healthy individuals. Compared with a dim illumination, the intense illumination negatively impacted performance requiring sustained attention; however, it positively impacted subjective alertness and mood and had no impact on serum melatonin levels. These results suggest that brief exposure to bright light in the morning hours can improve subjective measures of mood and alertness, but can also have detrimental effects on mental performance as a result of visual distraction. Therefore, it is important that adequate lighting should correspond to both non-visual and visual demands. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Experimental evaluation of candidate graphical microburst alert displays
NASA Technical Reports Server (NTRS)
Wanke, Craig R.; Hansman, R. John
1992-01-01
A piloted flight simulator experiment was conducted to evaluate issues related to the display of microburst alerts on electronic cockpit instrumentation. Issues addressed include display clarity, usefulness of multilevel microburst intensity information, and whether information from multiple sensors should be presented separately or 'fused' into combined alerts. Nine active airline pilots of 'glass cockpit' aircraft participated in the study. Microburst alerts presented on a moving map display were found to be visually clear and useful to pilots. Also, multilevel intensity information coded by colors or patterns was found to be important for decision making purposes. Pilot opinion was mixed on whether to 'fuse' data from multiple sensors, and some resulting design tradeoffs were identified. The positional information included in the graphical alert presentation was found useful by the pilots for planning lateral missed approach maneuvers, but may result in deviations which could interfere with normal airport operations. A number of flight crew training issues were also identified.
Ramirez-Arcos, Sandra; DiFranco, Caesar; McIntyre, Terri; Goldman, Mindy
2017-09-01
Canadian Blood Services screens 100% of platelet concentrates (PCs) for bacterial contamination with the BacT/ALERT system. Quality-control sterility testing of 1% (≥10 units) of outdated PCs is performed monthly. Data from routine screening, quality-control testing, and septic reactions obtained from 2010 to 2016 are presented herein. In total, 601,988 buffy coat PC pools and 186,737 apheresis PCs were routinely screened with aerobic cultures over 6 years. Outdate quality-control testing of 8535 buffy coat and 8498 apheresis PCs was performed using aerobic and anaerobic cultures during the same period. Results were classified as "true-positives" when the same bacterium was isolated in initial and confirmatory cultures or "false-negatives" when bacteria were missed in early screening and were captured during quality-control sterility testing or through investigation of sepsis cases. During routine screening, the true-positive rates between buffy coat (0.94 per 10,000) and apheresis (0.96 per 10,000) PCs were similar (p = 0.9473). Seventy-five bacteria isolated during PC screening included Gram-positive and Gram-negative organisms. Six false-negative septic reactions were reported that implicated coagulase-negative staphylococci (n = 3) and Staphylococcus aureus (n = 3) for approximate rates of 1 per 100,000 transfusion reactions and 1 per 500,000 fatalities. During quality-control testing, the false-negative rates between buffy coat (8 per 10,000) and apheresis (9 per 10,000) PCs were similar (p = 0.7897). All 15 quality-control isolates were Gram-positive bacteria. The current bacterial screening protocol is efficacious for identifying Gram-negative bacteria. However, the high proportion of Gram-positive organisms detected on outdate quality-control testing and septic transfusion events demonstrates a residual safety risk that merits further intervention. © 2017 AABB.
... of feeling. During this examination, the surgeon will position the foot and tap on the nerve to ... a city or last name. Use your current position? {{ps.position.alert.message}} Getting your location, one ...
Continuous glucose monitoring: quality of hypoglycaemia detection.
Zijlstra, E; Heise, T; Nosek, L; Heinemann, L; Heckermann, S
2013-02-01
To evaluate the accuracy of a (widely used) continuous glucose monitoring (CGM)-system and its ability to detect hypoglycaemic events. A total of 18 patients with type 1 diabetes mellitus used continuous glucose monitoring (Guardian REAL-Time CGMS) during two 9-day in-house periods. A hypoglycaemic threshold alarm alerted patients to sensor readings <70 mg/dl. Continuous glucose monitoring sensor readings were compared to laboratory reference measurements taken every 4 h and in case of a hypoglycaemic alarm. A total of 2317 paired data points were evaluated. Overall, the mean absolute relative difference (MARD) was 16.7%. The percentage of data points in the clinically accurate or acceptable Clarke Error Grid zones A + B was 94.6%. In the hypoglycaemic range, accuracy worsened (MARD 38.8%) leading to a failure to detect more than half of the true hypoglycaemic events (sensitivity 37.5%). Furthermore, more than half of the alarms that warn patients for hypoglycaemia were false (false alert rate 53.3%). Above the low alert threshold, the sensor confirmed 2077 of 2182 reference values (specificity 95.2%). Patients using continuous glucose monitoring should be aware of its limitation to accurately detect hypoglycaemia. © 2012 Blackwell Publishing Ltd.
NASA Astrophysics Data System (ADS)
Cua, G. B.; Fischer, M.; Caprio, M.; Heaton, T. H.; Cisn Earthquake Early Warning Project Team
2010-12-01
The Virtual Seismologist (VS) earthquake early warning (EEW) algorithm is one of 3 EEW approaches being incorporated into the California Integrated Seismic Network (CISN) ShakeAlert system, a prototype EEW system that could potentially be implemented in California. The VS algorithm, implemented by the Swiss Seismological Service at ETH Zurich, is a Bayesian approach to EEW, wherein the most probable source estimate at any given time is a combination of contributions from a likehihood function that evolves in response to incoming data from the on-going earthquake, and selected prior information, which can include factors such as network topology, the Gutenberg-Richter relationship or previously observed seismicity. The VS codes have been running in real-time at the Southern California Seismic Network since July 2008, and at the Northern California Seismic Network since February 2009. We discuss recent enhancements to the VS EEW algorithm that are being integrated into CISN ShakeAlert. We developed and continue to test a multiple-threshold event detection scheme, which uses different association / location approaches depending on the peak amplitudes associated with an incoming P pick. With this scheme, an event with sufficiently high initial amplitudes can be declared on the basis of a single station, maximizing warning times for damaging events for which EEW is most relevant. Smaller, non-damaging events, which will have lower initial amplitudes, will require more picks to initiate an event declaration, with the goal of reducing false alarms. This transforms the VS codes from a regional EEW approach reliant on traditional location estimation (and the requirement of at least 4 picks as implemented by the Binder Earthworm phase associator) into an on-site/regional approach capable of providing a continuously evolving stream of EEW information starting from the first P-detection. Real-time and offline analysis on Swiss and California waveform datasets indicate that the multiple-threshold approach is faster and more reliable for larger events than the earlier version of the VS codes. In addition, we provide evolutionary estimates of the probability of false alarms (PFA), which is an envisioned output stream of the CISN ShakeAlert system. The real-time decision-making approach envisioned for CISN ShakeAlert users, where users specify a threshhold PFA in addition to thresholds on peak ground motion estimates, has the potential to increase the available warning time for users with high tolerance to false alarms without compromising the needs of users with lower tolerances to false alarms.
Attentional networks and visuospatial working memory capacity in social anxiety.
Moriya, Jun
2018-02-01
Social anxiety is associated with attentional bias and working memory for emotional stimuli; however, the ways in which social anxiety affects cognitive functions involving non-emotional stimuli remains unclear. The present study focused on the role of attentional networks (i.e. alerting, orienting, and executive control networks) and visuospatial working memory capacity (WMC) for non-emotional stimuli in the context of social anxiety. One hundred and seventeen undergraduates completed questionnaires on social anxiety. They then performed an attentional network test and a change detection task to measure visuospatial WMC. Orienting network and visuospatial WMC were positively correlated with social anxiety. A multiple regression analysis showed significant positive associations of alerting, orienting, and visuospatial WMC with social anxiety. Alerting, orienting networks, and high visuospatial WMC for non-emotional stimuli may predict degree of social anxiety.
Ly, Sovann; Arashiro, Takeshi; Ieng, Vanra; Tsuyuoka, Reiko; Parry, Amy; Horwood, Paul; Heng, Seng; Hamid, Sarah; Vandemaele, Katelijn; Chin, Savuth; Sar, Borann; Arima, Yuzo
2017-01-01
To establish seasonal and alert thresholds and transmission intensity categories for influenza to provide timely triggers for preventive measures or upscaling control measures in Cambodia. Using Cambodia's influenza-like illness (ILI) and laboratory-confirmed influenza surveillance data from 2009 to 2015, three parameters were assessed to monitor influenza activity: the proportion of ILI patients among all outpatients, proportion of ILI samples positive for influenza and the product of the two. With these parameters, four threshold levels (seasonal, moderate, high and alert) were established and transmission intensity was categorized based on a World Health Organization alignment method. Parameters were compared against their respective thresholds. Distinct seasonality was observed using the two parameters that incorporated laboratory data. Thresholds established using the composite parameter, combining syndromic and laboratory data, had the least number of false alarms in declaring season onset and were most useful in monitoring intensity. Unlike in temperate regions, the syndromic parameter was less useful in monitoring influenza activity or for setting thresholds. Influenza thresholds based on appropriate parameters have the potential to provide timely triggers for public health measures in a tropical country where monitoring and assessing influenza activity has been challenging. Based on these findings, the Ministry of Health plans to raise general awareness regarding influenza among the medical community and the general public. Our findings have important implications for countries in the tropics/subtropics and in resource-limited settings, and categorized transmission intensity can be used to assess severity of potential pandemic influenza as well as seasonal influenza.
The effect of music-induced mood on attentional networks.
Jiang, Jun; Scolaro, Ashley J; Bailey, Kira; Chen, Antao
2011-06-01
Attention network theory suggests that there are three separate neural networks that execute the discrete functions of alerting, orienting, and executive attention. Previous research on the influence of mood on attention has shown subtle and inconsistent results. The attention network theory may aid in clarifying the influence of mood on attention. The present study investigated the influence of mood on attentional networks in a normal population. Participants performed the Attention Network Test (ANT), which provides functional measures of alerting, orienting, and executive attention. Positive or negative mood was induced by listening to music with a positive or negative valence, respectively; neutral mood was induced by reading a collection of basic facts about China. The results revealed that negative mood led to a significantly higher alerting efficiency relative to other moods, while there were no significant mood effects on orienting or executive attention efficiency. According to the algorithm underlying the ANT, the higher alerting efficiency in the negative mood condition can be attributed to relatively greater benefits of cueing effects. The findings are discussed in the context of the noradrenergic system and of evolutionary significance. Specifically, the increase in the alerting function during negative mood states may be due to the modulation effect of negative mood on the noradrenergic system, and/or to the survival benefit resulting from an increase in automatic vigilance towards negative information. The current results suggest that as the influence of negative mood on attention appears to specifically consist in an enhanced alerting function, it may not be found in studies where the three attentional networks are not dissociated.
Wüppenhorst, N; Consoir, C; Lörch, D; Schneider, C
2012-10-01
Several protocols for direct matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) from positive blood cultures are currently used to speed up the diagnostic process of bacteraemia. Identification rates are high and results are accurate for the BACTEC™ system and for charcoal-free bottles. Only a few studies have evaluated protocols for charcoal-containing BacT/ALERT bottles reaching substantially lower identification rates. We established a new protocol for sample preparation from aerobic and anaerobic positive charcoal-containing BacT/ALERT blood culture bottles and measured the protein profiles (n = 167). Then, we integrated this protocol in the routine workflow of our laboratory (n = 212). During the establishment of our protocol, 74.3 % of bacteria were correctly identified to the species level, in 23.4 %, no result and in 2.4 %, a false identification were obtained. Reliable criteria for correct species identification were a score value ≥1.400 and a best match on rank 1-3 of the same species. Identification rates during routine workflow were 77.8 % for correct identification, 20.8 % for not identified samples and 1.4 % for discordant identification. In conclusion, our results indicate that MALDI-TOF MS is possible, even from charcoal-containing blood cultures. Reliable criteria for correct species identification are a score value ≥1.400 and a best match on rank 1-3 of a single species.
Given, Douglas D.; Cochran, Elizabeth S.; Heaton, Thomas; Hauksson, Egill; Allen, Richard; Hellweg, Peggy; Vidale, John; Bodin, Paul
2014-01-01
Earthquake Early Warning (EEW) systems can provide as much as tens of seconds of warning to people and automated systems before strong shaking arrives. The United States Geological Survey (USGS) and its partners are developing such an EEW system, called ShakeAlert, for the West Coast of the United States. This document describes the technical implementation of that system, which leverages existing stations and infrastructure of the Advanced National Seismic System (ANSS) regional networks to achieve this new capability. While significant progress has been made in developing the ShakeAlert early warning system, improved robustness of each component of the system and additional testing and certification are needed for the system to be reliable enough to issue public alerts. Major components of the system include dense networks of ground motion sensors, telecommunications from those sensors to central processing systems, algorithms for event detection and alert creation, and distribution systems to alert users. Capital investment costs for a West Coast EEW system are projected to be $38.3M, with additional annual maintenance and operations totaling $16.1M—in addition to current ANSS expenditures for earthquake monitoring. An EEW system is complementary to, but does not replace, other strategies to mitigate earthquake losses. The system has limitations: false and missed alerts are possible, and the area very near to an earthquake epicenter may receive little or no warning. However, such an EEW system would save lives, reduce injuries and damage, and improve community resilience by reducing longer-term economic losses for both public and private entities.
Dormann, H; Criegee-Rieck, M; Neubert, A; Egger, T; Levy, M; Hahn, E G; Brune, K
2004-02-01
To investigate the effectiveness of a computer monitoring system that detects adverse drug reactions (ADRs) by laboratory signals in gastroenterology. A prospective, 6-month, pharmaco-epidemiological survey was carried out on a gastroenterological ward at the University Hospital Erlangen-Nuremberg. Two methods were used to identify ADRs. (i) All charts were reviewed daily by physicians and clinical pharmacists. (ii) A computer monitoring system generated a daily list of automatic laboratory signals and alerts of ADRs, including patient data and dates of events. One hundred and nine ADRs were detected in 474 admissions (377 patients). The computer monitoring system generated 4454 automatic laboratory signals from 39 819 laboratory parameters tested, and issued 2328 alerts, 914 (39%) of which were associated with ADRs; 574 (25%) were associated with ADR-positive admissions. Of all the alerts generated, signals of hepatotoxicity (1255), followed by coagulation disorders (407) and haematological toxicity (207), were prevalent. Correspondingly, the prevailing ADRs were concerned with the metabolic and hepato-gastrointestinal system (61). The sensitivity was 91%: 69 of 76 ADR-positive patients were indicated by an alert. The specificity of alerts was increased from 23% to 76% after implementation of an automatic laboratory signal trend monitoring algorithm. This study shows that a computer monitoring system is a useful tool for the systematic and automated detection of ADRs in gastroenterological patients.
Non-visual biological effects of light on human cognition, alertness, and mood
NASA Astrophysics Data System (ADS)
Li, Huaye; Wang, Huihui; Shen, Junfei; Sun, Peng; Xie, Ting; Zhang, Siman; Zheng, Zhenrong
2017-09-01
Light exerts non-visual effects on a wide range of biological functions and behavior apart from the visual effect. Light can regulate human circadian rhythms, like the secretion of melatonin and cortisol. Light also has influence on body's physiological parameters, such as blood pressure, heart rate and body temperature. However, human cognitive performance, alertness and mood under different lighting conditions have not been considered thoroughly especially for the complicated visual task like surgical operating procedure. In this paper, an experiment was conducted to investigate the cognition, alertness and mood of healthy participants in a simulated operating room (OR) in the hospital. A LED surgical lamp was used as the light source, which is mixed by three color LEDs (amber, green and blue). The surgical lamp is flexible on both spectrum and intensity. Exposed to different light settings, which are varied from color temperature and luminance, participants were asked to take psychomotor vigilance task (PVT) for alertness measurement, alphabet test for cognitive performance measurement, positive and negative affect schedule (PANAS) for mood measurement. The result showed the participants' cognitive performance, alertness and mood are related to the color temperature and luminance of the LED light. This research will have a guidance for the surgical lighting environment, which can not only enhance doctors' efficiency during the operations, but also create a positive and peaceful surgical lighting environment.
Measurement of signal use and vehicle turns as indication of driver cognition.
Wallace, Bruce; Goubran, Rafik; Knoefel, Frank
2014-01-01
This paper uses data analytics to provide a method for the measurement of a key driving task, turn signal usage as a measure of an automatic over-learned cognitive function drivers. The paper augments previously reported more complex executive function cognition measures by proposing an algorithm that analyzes dashboard video to detect turn indicator use with 100% accuracy without any false positives. The paper proposes two algorithms that determine the actual turns made on a trip. The first through analysis of GPS location traces for the vehicle, locating 73% of the turns made with a very low false positive rate of 3%. A second algorithm uses GIS tools to retroactively create turn by turn directions. Fusion of GIS and GPS information raises performance to 77%. The paper presents the algorithm required to measure signal use for actual turns by realigning the 0.2Hz GPS data, 30fps video and GIS turn events. The result is a measure that can be tracked over time and changes in the driver's performance can result in alerts to the driver, caregivers or clinicians as indication of cognitive change. A lack of decline can also be shared as reassurance.
Shuptar, Susan L.; Milord, Philippe; Essick, Connor J.; Nevrekar, Reshma; Granovsky, Svetlana L.; Seo, Susan K.; Martin, Steven C.; Pessin, Melissa S.
2015-01-01
We implemented hospital information system (HIS) alerts to deter unnecessary test orders for ovum and parasite (O&P) exams and Clostridium difficile PCR. The HIS alerts decreased noncompliant O&P orders (orders after >72 h of hospitalization) from 49.8% to 30.9%, an overall decrease of 19%, and reduced noncompliant C. difficile PCR orders (orders <7 days after a previous positive result) from 30.6% to 19.2%, an overall decrease of 31.9%. PMID:26063860
Broyer, Patrick; Perrot, Nadine; Rostaing, Hervé; Blaze, Jérome; Pinston, Frederic; Gervasi, Gaspard; Charles, Marie-Hélène; Dachaud, Fabien; Dachaud, Jacques; Moulin, Frederic; Cordier, Sylvain; Dauwalder, Olivier; Meugnier, Hélène; Vandenesch, Francois
2018-01-01
Sepsis is the leading cause of death among patients in intensive care units (ICUs) requiring an early diagnosis to introduce efficient therapeutic intervention. Rapid identification (ID) of a causative pathogen is key to guide directed antimicrobial selection and was recently shown to reduce hospitalization length in ICUs. Direct processing of positive blood cultures by MALDI-TOF MS technology is one of the several currently available tools used to generate rapid microbial ID. However, all recently published protocols are still manual and time consuming, requiring dedicated technician availability and specific strategies for batch processing. We present here a new prototype instrument for automated preparation of Vitek ® MS slides directly from positive blood culture broth based on an "all-in-one" extraction strip. This bench top instrument was evaluated on 111 and 22 organisms processed using artificially inoculated blood culture bottles in the BacT/ALERT ® 3D (SA/SN blood culture bottles) or the BacT/ALERT Virtuo TM system (FA/FN Plus bottles), respectively. Overall, this new preparation station provided reliable and accurate Vitek MS species-level identification of 87% (Gram-negative bacteria = 85%, Gram-positive bacteria = 88%, and yeast = 100%) when used with BacT/ALERT ® 3D and of 84% (Gram-negative bacteria = 86%, Gram-positive bacteria = 86%, and yeast = 75%) with Virtuo ® instruments, respectively. The prototype was then evaluated in a clinical microbiology laboratory on 102 clinical blood culture bottles and compared to routine laboratory ID procedures. Overall, the correlation of ID on monomicrobial bottles was 83% (Gram-negative bacteria = 89%, Gram-positive bacteria = 79%, and yeast = 78%), demonstrating roughly equivalent performance between manual and automatized extraction methods. This prototype instrument exhibited a high level of performance regardless of bottle type or BacT/ALERT system. Furthermore, blood culture workflow could potentially be improved by converting direct ID of positive blood cultures from a batch-based to real-time and "on-demand" process.
47 CFR 10.540 - Attestation requirement. [Reserved
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Attestation requirement. [Reserved] 10.540 Section 10.540 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Equipment Requirements § 10.540 Attestation requirement. [Reserved] ...
Terminal Area Conflict Detection and Resolution Tool
NASA Technical Reports Server (NTRS)
Verma, Savita Arora
2011-01-01
This poster will describe analysis of a conflict detection and resolution tool for the terminal area called T-TSAFE. With altitude clearance information, the tool can reduce false alerts to as low as 2 per hour.
Behavioral and Brain Measures of Phasic Alerting Effects on Visual Attention.
Wiegand, Iris; Petersen, Anders; Finke, Kathrin; Bundesen, Claus; Lansner, Jon; Habekost, Thomas
2017-01-01
In the present study, we investigated effects of phasic alerting on visual attention in a partial report task, in which half of the displays were preceded by an auditory warning cue. Based on the computational Theory of Visual Attention (TVA), we estimated parameters of spatial and non-spatial aspects of visual attention and measured event-related lateralizations (ERLs) over visual processing areas. We found that the TVA parameter sensory effectiveness a , which is thought to reflect visual processing capacity, significantly increased with phasic alerting. By contrast, the distribution of visual processing resources according to task relevance and spatial position, as quantified in parameters top-down control α and spatial bias w index , was not modulated by phasic alerting. On the electrophysiological level, the latencies of ERLs in response to the task displays were reduced following the warning cue. These results suggest that phasic alerting facilitates visual processing in a general, unselective manner and that this effect originates in early stages of visual information processing.
ERIC Educational Resources Information Center
Donnelly, John E.
2010-01-01
Early alert strategies are an increasingly common way to address students' ongoing needs for greater academic and social engagement by enabling a positive campus environment and appropriate academic support; Kuh et al. find these to be necessary engagement conditions. Young and Fry show the benefits of student metacognition, or awareness of…
47 CFR 80.1091 - Ship radio equipment-Sea areas A1, A2, and A3.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the transmission of ship-to-shore distress alerts by a radio service operating either: (i) Through the..., the position from which the ship is normally navigated); or (ii) On HF using DSC: or (iii) Through the...); and (3) Means of initiating the transmission of ship-to-shore distress alerts by a radio-communication...
47 CFR 80.1091 - Ship radio equipment-Sea areas A1, A2, and A3.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the transmission of ship-to-shore distress alerts by a radio service operating either: (i) Through the..., the position from which the ship is normally navigated); or (ii) On HF using DSC: or (iii) Through the...); and (3) Means of initiating the transmission of ship-to-shore distress alerts by a radio-communication...
47 CFR 80.1091 - Ship radio equipment-Sea areas A1, A2, and A3.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the transmission of ship-to-shore distress alerts by a radio service operating either: (i) Through the..., the position from which the ship is normally navigated); or (ii) On HF using DSC: or (iii) Through the...); and (3) Means of initiating the transmission of ship-to-shore distress alerts by a radio-communication...
Congestrì, Francesco; Pedna, Maria Federica; Fantini, Michela; Samuelli, Michela; Schiavone, Pasqua; Torri, Arianna; Bertini, Stefania; Sambri, Vittorio
2017-09-01
The early detection of bacteraemia and fungemia is of paramount importance to guide antimicrobial therapy in septic patients. In this study the 'time to detection' (TTD) value for the new blood culture system BacT/ALERT VIRTUO (VIRTUO) was evaluated in 1462 positive clinical bottles and compared with the TTD for 1601 positive clinical bottles incubated in the BacT/ALERT 3D system (BTA-3D). The most representative microorganisms isolated from bottles incubated in both blood culture systems were divided into eight categories (in order of frequency): coagulase-negative staphylococci (CoNS), Escherichia coli, Enterobacteriaceae (other than E. coli), Staphylococcus aureus, Enterococcus spp, viridans group streptococci, Pseudomonas aeruginosa, and Candida spp. The comparison of TTD values for the two blood culture systems strongly indicated that growth of the first five groups listed above was detected earlier with VIRTUO than with BTA-3D (p < 0.05). The new VIRTUO blood culture system can reduce the TTD for more than 75% of isolated microorganisms. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Technical Reports Server (NTRS)
Chelette, T. L.; Repperger, Daniel W.; Albery, W. B.
1991-01-01
An effort was initiated at the Armstrong Aerospace Medical Research Laboratory (AAMRL) to investigate the improvement of the situational awareness of a pilot with respect to his aircraft's spatial orientation. The end product of this study is a device to alert a pilot to potentially disorienting situations. Much like a ground collision avoidance system (GCAS) is used in fighter aircraft to alert the pilot to 'pull up' when dangerous flight paths are predicted, this device warns the pilot to put a higher priority on attention to the orientation instrument. A Kalman filter was developed which estimates the pilot's perceived position and orientation. The input to the Kalman filter consists of two classes of data. The first class of data consists of noise parameters (indicating parameter uncertainty), conflict signals (e.g. vestibular and kinesthetic signal disagreement), and some nonlinear effects. The Kalman filter's perceived estimates are now the sum of both Class 1 data (good information) and Class 2 data (distorted information). When the estimated perceived position or orientation is significantly different from the actual position or orientation, the pilot is alerted.
Validation of the CME Geomagnetic Forecast Alerts Under the COMESEP Alert System
NASA Astrophysics Data System (ADS)
Dumbović, Mateja; Srivastava, Nandita; Rao, Yamini K.; Vršnak, Bojan; Devos, Andy; Rodriguez, Luciano
2017-08-01
Under the European Union 7th Framework Programme (EU FP7) project Coronal Mass Ejections and Solar Energetic Particles (COMESEP, http://comesep.aeronomy.be), an automated space weather alert system has been developed to forecast solar energetic particles (SEP) and coronal mass ejection (CME) risk levels at Earth. The COMESEP alert system uses the automated detection tool called Computer Aided CME Tracking (CACTus) to detect potentially threatening CMEs, a drag-based model (DBM) to predict their arrival, and a CME geoeffectiveness tool (CGFT) to predict their geomagnetic impact. Whenever CACTus detects a halo or partial halo CME and issues an alert, the DBM calculates its arrival time at Earth and the CGFT calculates its geomagnetic risk level. The geomagnetic risk level is calculated based on an estimation of the CME arrival probability and its likely geoeffectiveness, as well as an estimate of the geomagnetic storm duration. We present the evaluation of the CME risk level forecast with the COMESEP alert system based on a study of geoeffective CMEs observed during 2014. The validation of the forecast tool is made by comparing the forecasts with observations. In addition, we test the success rate of the automatic forecasts (without human intervention) against the forecasts with human intervention using advanced versions of the DBM and CGFT (independent tools available at the Hvar Observatory website, http://oh.geof.unizg.hr). The results indicate that the success rate of the forecast in its current form is unacceptably low for a realistic operation system. Human intervention improves the forecast, but the false-alarm rate remains unacceptably high. We discuss these results and their implications for possible improvement of the COMESEP alert system.
The Explosive Universe with Gaia
NASA Astrophysics Data System (ADS)
Wyrzykowski, Łukasz; Hodgkin, Simon T.; Blagorodnova, Nadejda; Belokurov, Vasily
2014-01-01
The Gaia mission will observe the entire sky for 5 years providing ultra-precise astrometric, photometric and spectroscopic measurements for a billion stars in the Galaxy. Hence, naturally, Gaia becomes an all-sky multi-epoch photometric survey, which will monitor and detect variability with millimag precision as well as new transient sources such as supernovae, novae, microlensing events, tidal disruption events, asteroids, among others. Gaia data-flow allows for quick detections of anomalies within 24-48h after the observation. Such near-real-time survey will be able to detect about 6000 supernovae brighter than 19 mag up to redshifts of Z 0.15. The on-board low-resolution (R 100) spectrograph will allow for early and robust classification of transients and minimise the false-alert rate, even providing the estimates on redshift for supernovae. Gaia will also offer a unique possibility for detecting astrometric shifts in microlensing events, which, combined with Gaia's and ground-based photometry, will provide unique mass measurements of lenses, constrains on the dark matter content in the Milky Way and possible detections of free floating black holes. Alerts from Gaia will be publicly available soon after the detection is verified and tested. First alerts are expected early in 2014 and those will be used for ground-based verification. All facilities are invited to join the verification and the follow-up effort. Alerts will be published on a web page, via Skyalert.org and via emailing list. Each alert will contain coordinates, Gaia light curve and low-resolution spectra, classification and cross-matching results. More information on the Gaia Science Alerts can be found here: http://www.ast.cam.ac.uk/ioa/wikis/gsawgwiki/ The full version of the poster is available here: http://www.ast.cam.ac.uk/ioa/wikis/gsawgwiki/images/1/13/GaiaAlertsPosterIAUS298.pdf
... can conceal sharp objects underwater. People living with diabetes should never go barefoot, even indoors, because their nervous system may not ... Use your current position? {{ps.position.alert.message}} Getting your location, one ...
Management of Patient-Reported Outcome (PRO) Alerts in Clinical Trials: A Cross Sectional Survey.
Kyte, Derek; Ives, Jonathan; Draper, Heather; Calvert, Melanie
2016-01-01
Assessment of patient-reported outcomes (PROs) provides valuable information to inform patient-centered care, but may also reveal 'PRO alerts': psychological distress or physical symptoms that may require an immediate response. Ad-hoc management of PRO alerts in clinical trials may result in suboptimal patient care or potentially bias trial results. To gain greater understanding of current practice in PRO alert management we conducted a national survey of personnel involved in clinical trials with a PRO endpoint. We conducted a national cross-sectional survey of 767 UK-based research nurses, data managers/coordinators, trial managers and chief/principal investigators involved in clinical trials using PROs. Respondents were self-selected volunteers from a non-randomised sample of eligible individuals recruited via 55 UK Clinical Research Collaboration Registered Clinical Trials Units and 19 Comprehensive Local Research Networks. Questions centred on the proportion of trial personnel encountering alerts, how staff responded to PRO alerts and whether current guidance was deemed sufficient to support research personnel. We undertook descriptive analyses of the quantitative data and directed thematic analysis of free-text comments. 20% of research nurses did not view completed PRO questionnaires and were not in a position to discover alerts, 39-50% of the remaining respondent group participants reported encountering PRO alerts. Of these, 83% of research nurses and 54% of data managers/trial coordinators reported taking action to assist the trial participant, but less than half were able to record the intervention in the trial documentation. Research personnel reported current PRO alert guidance/training was insufficient. Research personnel are intermittently exposed to PRO alerts. Some intervene to help trial participants, but are not able to record this intervention in the trial documentation, risking co-intervention bias. Other staff do not check PRO information during the trial, meaning alerts may remain undiscovered, or do not respond to alerts if they are inadvertently encountered; both of which may impact on patient safety. Guidance is needed to support PRO alert management that protects the interests of trial participants whilst avoiding potential bias.
NASA Technical Reports Server (NTRS)
Cajochen, C.; Zeitzer, J. M.; Czeisler, C. A.; Dijk, D. J.
2000-01-01
Light can elicit both circadian and acute physiological responses in humans. In a dose response protocol men and women were exposed to illuminances ranging from 3 to 9100 lux for 6.5 h during the early biological night after they had been exposed to <3 lux for several hours. Light exerted an acute alerting response as assessed by a reduction in the incidence of slow-eye movements, a reduction of EEG activity in the theta-alpha frequencies (power density in the 5-9 Hz range) as well as a reduction in self-reported sleepiness. This alerting response was positively correlated with the degree of melatonin suppression by light. In accordance with the dose response function for circadian resetting and melatonin suppression, the responses of all three indices of alertness to variations in illuminance were consistent with a logistic dose response curve. Half of the maximum alerting response to bright light of 9100 lux was obtained with room light of approximately 100 lux. This sensitivity to light indicates that variations in illuminance within the range of typical, ambient, room light (90-180 lux) can have a significant impact on subjective alertness and its electrophysiologic concomitants in humans during the early biological night.
Wipfli, Rolf; Ehrler, Frederic; Bediang, Georges; Bétrancourt, Mireille; Lovis, Christian
2016-06-02
As demonstrated in several publications, low positive predictive value alerts in computerized physician order entry (CPOE) induce fatigue and may interrupt physicians unnecessarily during prescription of medication. Although it is difficult to increase the consideration of medical alerts by physician through an improvement of their predictive value, another approach consists to act on the way they are presented. The interruption management model inspired us to propose an alternative alert display strategy of regrouping the alerts in the screen layout, as a possible solution for reducing the interruption in physicians' workflow. In this study, we compared 2 CPOE designs based on a particular alert presentation strategy: one design involved regrouping the alerts in a single place on the screen, and in the other, the alerts were located next to the triggering information. Our objective was to evaluate experimentally whether the new design led to fewer interruptions in workflow and if it affected alert handling. The 2 CPOE designs were compared in a controlled crossover randomized trial. All interactions with the system and eye movements were stored for quantitative analysis. The study involved a group of 22 users consisting of physicians and medical students who solved medical scenarios containing prescription tasks. Scenario completion time was shorter when the alerts were regrouped (mean 117.29 seconds, SD 36.68) than when disseminated on the screen (mean 145.58 seconds, SD 75.07; P=.045). Eye tracking revealed that physicians fixated longer on alerts in the classic design (mean 119.71 seconds, SD 76.77) than in the centralized alert design (mean 70.58 seconds, SD 33.53; P=.001). Visual switches between prescription and alert areas, indicating interruption, were reduced with centralized alerts (mean 41.29, SD 21.26) compared with the classic design (mean 57.81, SD 35.97; P=.04). Prescription behavior (ie, prescription changes after alerting), however, did not change significantly between the 2 strategies of display. The After-Scenario Questionnaire (ASQ) that was filled out after each scenario showed that overall satisfaction was significantly rated lower when alerts were regrouped (mean 4.37, SD 1.23) than when displayed next to the triggering information (mean 5.32, SD 0.94; P=.02). Centralization of alerts in a table might be a way to motivate physicians to manage alerts more actively, in a meaningful way, rather than just being interrupted by them. Our study could not provide clear recommendations yet, but provides objective data through a cognitive psychological approach. Future tests should work on standardized scenarios that would enable to not only measure physicians' behavior (visual fixations and handling of alerts) but also validate those actions using clinical criteria.
Otto, Caitlin C; Shuptar, Susan L; Milord, Philippe; Essick, Connor J; Nevrekar, Reshma; Granovsky, Svetlana L; Seo, Susan K; Babady, N Esther; Martin, Steven C; Tang, Yi-Wei; Pessin, Melissa S
2015-08-01
We implemented hospital information system (HIS) alerts to deter unnecessary test orders for ovum and parasite (O&P) exams and Clostridium difficile PCR. The HIS alerts decreased noncompliant O&P orders (orders after >72 h of hospitalization) from 49.8% to 30.9%, an overall decrease of 19%, and reduced noncompliant C. difficile PCR orders (orders <7 days after a previous positive result) from 30.6% to 19.2%, an overall decrease of 31.9%. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Automation bias in electronic prescribing.
Lyell, David; Magrabi, Farah; Raban, Magdalena Z; Pont, L G; Baysari, Melissa T; Day, Richard O; Coiera, Enrico
2017-03-16
Clinical decision support (CDS) in e-prescribing can improve safety by alerting potential errors, but introduces new sources of risk. Automation bias (AB) occurs when users over-rely on CDS, reducing vigilance in information seeking and processing. Evidence of AB has been found in other clinical tasks, but has not yet been tested with e-prescribing. This study tests for the presence of AB in e-prescribing and the impact of task complexity and interruptions on AB. One hundred and twenty students in the final two years of a medical degree prescribed medicines for nine clinical scenarios using a simulated e-prescribing system. Quality of CDS (correct, incorrect and no CDS) and task complexity (low, low + interruption and high) were varied between conditions. Omission errors (failure to detect prescribing errors) and commission errors (acceptance of false positive alerts) were measured. Compared to scenarios with no CDS, correct CDS reduced omission errors by 38.3% (p < .0001, n = 120), 46.6% (p < .0001, n = 70), and 39.2% (p < .0001, n = 120) for low, low + interrupt and high complexity scenarios respectively. Incorrect CDS increased omission errors by 33.3% (p < .0001, n = 120), 24.5% (p < .009, n = 82), and 26.7% (p < .0001, n = 120). Participants made commission errors, 65.8% (p < .0001, n = 120), 53.5% (p < .0001, n = 82), and 51.7% (p < .0001, n = 120). Task complexity and interruptions had no impact on AB. This study found evidence of AB omission and commission errors in e-prescribing. Verification of CDS alerts is key to avoiding AB errors. However, interventions focused on this have had limited success to date. Clinicians should remain vigilant to the risks of CDS failures and verify CDS.
Towards Deep Learning from Twitter for Improved Tsunami Alerts and Advisories
NASA Astrophysics Data System (ADS)
Lumb, L. I.; Freemantle, J. R.
2017-12-01
Data from social-networking services increasingly complements that from traditional sources in scenarios that seek to 'cultivate' situational awareness. As false-positive alerts and retracted advisories appear to suggest, establishing a causal connection between earthquakes and tsunamis remains an extant challenge that could prove life-critical. Because posts regarding such natural disasters typically 'trend' in real time via social media, we extract tweets in an effort to elucidate this cause-effect relationship from a very different perspective. To extract content of potential geophysical value from a multiplicity of 140-character tweets streamed in real time, we apply Natural Language Processing (NLP) to the unstructured data and metadata available via Twitter. In Deep Learning from Twitter, words such as "earthquake" are represented as vectors embedded in a corpora of tweets, whose proximity to words such as "tsunami" can be subsequently quantified. Furthermore, when use is made of pre-trained word vectors available for various reference corpora, geophysically credible tweets are rendered distinguishable by quantifying similarities through use of a word-vector dot product. Finally, word-vector analogies are shown to be promising in terms of deconstructing the earthquake-tsunami relationship in terms of the cumulative effect of multiple, contributing factors (see figure). Because diction is anticipated to differ in tweets that follow a tsunami-producing earthquake, our emphasis here is on the re-analysis of actual event data extracted from Twitter that quantifies word sense relative to earthquake-only events. If proven viable, our approach could complement those measures already in place to deliver real-time alerts and advisories following tsunami-causing earthquakes. With climate change accelerating the frequency of glacial calving, and in so doing providing an alternate, potential source for tsunamis, our approach is anticipated to be of value in broader contexts.
Schmidt, V; Jarosch, A; März, P; Sander, C; Vacata, V; Kalka-Moll, W
2012-03-01
Blood culture is probably the most significant specimen used for the diagnosis of bacterial infections, especially for bloodstream infections. In the present study, we compared the resin-containing BD BACTEC™ Plus-Aerobic (Becton Dickinson), non-charcoal-containing BacT/Alert(®) SA (bioMérieux), and charcoal-containing BacT/Alert(®) FA (bioMérieux) blood culture bottles with direct identification by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS). A total of 103 bacterial isolates, from clinical blood cultures, representing the most frequent 13 genera and 24 species were examined. Bacteria were extracted from positive blood culture broth by density centrifugation and then subjected to identification by MALDI-TOF MS using two different volumes and chemical treatments. Overall, correct identification by MALDI-TOF MS was obtained for the BD BACTEC™ Plus-Aerobic, BacT/Alert(®) SA, and BacT/Alert(®) FA blood culture bottles in 72%, 45.6%, and 23%, respectively, for gram-negative bacteria in 86.6%, 69.2%, and 47.1%, respectively, and for gram-positive bacteria in 60.0%, 28.8%, and 5.4%, respectively. The lack of identification was observed mainly with viridans streptococci. Depending on the blood culture bottles used in routine diagnostic procedures and the protocol for bacterial preparation, the applied MALDI-TOF MS represents an efficient and rapid method for direct bacterial identification.
47 CFR 10.330 - Provider infrastructure requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Provider infrastructure requirements. 10.330 Section 10.330 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.330 Provider infrastructure requirements. This section specifies the general...
47 CFR 10.330 - Provider infrastructure requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Provider infrastructure requirements. 10.330 Section 10.330 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.330 Provider infrastructure requirements. This section specifies the general...
47 CFR 10.330 - Provider infrastructure requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Provider infrastructure requirements. 10.330 Section 10.330 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.330 Provider infrastructure requirements. This section specifies the general...
47 CFR 10.330 - Provider infrastructure requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Provider infrastructure requirements. 10.330 Section 10.330 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.330 Provider infrastructure requirements. This section specifies the general...
47 CFR 10.330 - Provider infrastructure requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Provider infrastructure requirements. 10.330 Section 10.330 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.330 Provider infrastructure requirements. This section specifies the general...
Grant, Devon A; Honn, Kimberly A; Layton, Matthew E; Riedy, Samantha M; Van Dongen, Hans P A
2017-06-01
The psychomotor vigilance test (PVT) is widely used to measure reduced alertness due to sleep loss. Here, two newly developed, 3-min versions of the psychomotor vigilance test, one smartphone-based and the other tablet-based, were validated against a conventional 10-min laptop-based PVT. Sixteen healthy participants (ages 22-40; seven males, nine females) completed a laboratory study, which included a practice and a baseline day, a 38-h total sleep deprivation (TSD) period, and a recovery day, during which they performed the three different versions of the PVT every 3 h. For each version of the PVT, the number of lapses, mean response time (RT), and number of false starts showed statistically significant changes across the sleep deprivation and recovery days. The number of lapses on the laptop was significantly correlated with the numbers of lapses on the smartphone and tablet. The mean RTs were generally faster on the smartphone and tablet than on the laptop. All three versions of the PVT exhibited a time-on-task effect in RTs, modulated by time awake and time of day. False starts were relatively rare on all three PVTs. For the number of lapses, the effect sizes across 38 h of TSD were large for the laptop PVT and medium for the smartphone and tablet PVTs. These results indicate that the 3-min smartphone and tablet PVTs are valid instruments for measuring reduced alertness due to sleep deprivation and restored alertness following recovery sleep. The results also indicate that the loss of sensitivity on the 3-min PVTs may be mitigated by modifying the threshold defining lapses.
Implementing the European Neutron Monitor Service for the ESA SSA Program
NASA Astrophysics Data System (ADS)
Mavromichalaki, H.; Papaioannou, A.; Souvatzoglou, G.; Dimitroulakos, J.; Paschalis, P.; Gerontidou, M.; Sarlanis, Ch.
2013-09-01
Ground level enhancements (GLEs) are observed as significant intensity increases at neutron monitor measurements, followed by an intense solar flare and/or a very energetic coronal mass ejection. Due to their space weather impact it is crucial to establish a real-time operational system that would be in place to issue reliable and timely GLE Alerts. Such a Neutron Monitor Service that will be made available via the Space Weather Portal operated by the European Space Agency (ESA), under the Space Situational Awareness (SSA) Program, is currently under development. The ESA Neutron Monitor Service will provide two products: a web interface providing data from multiple Neutron Monitor stations as well as an upgraded GLE Alert. Both services are now under testing and validation and will probably enter to an operational phase next year. The core of this Neutron Monitor Service is the GLE Alert software, and therefore, the main goal of this research effort is to upgrade the existing GLE Alert software and to minimize the probability of false alarms. The ESA Neutron Monitor Service is building upon the infrastructure made available with the implementation of the High-Resolution Neutron Monitor Database (NMDB). In this work the structure of the ESA Neutron Monitor Service, the core of the novel GLE Alert Service and its validation results will be presented and further discussed.
Bunions (Hallux Abducto Valgus)
... a city or last name. Use your current position? {{ps.position.alert.message}} Getting your location, one moment... Please ... and Ankle Surgeons (ACFAS), All Rights Reserved. Privacy Statement | Disclaimer | Terms and Conditions | Site Map 8725 West ...
Dopamine in motivational control: rewarding, aversive, and alerting
Bromberg-Martin, Ethan S.; Matsumoto, Masayuki; Hikosaka, Okihide
2010-01-01
SUMMARY Midbrain dopamine neurons are well known for their strong responses to rewards and their critical role in positive motivation. It has become increasingly clear, however, that dopamine neurons also transmit signals related to salient but non-rewarding experiences such as aversive and alerting events. Here we review recent advances in understanding the reward and non-reward functions of dopamine. Based on this data, we propose that dopamine neurons come in multiple types that are connected with distinct brain networks and have distinct roles in motivational control. Some dopamine neurons encode motivational value, supporting brain networks for seeking, evaluation, and value learning. Others encode motivational salience, supporting brain networks for orienting, cognition, and general motivation. Both types of dopamine neurons are augmented by an alerting signal involved in rapid detection of potentially important sensory cues. We hypothesize that these dopaminergic pathways for value, salience, and alerting cooperate to support adaptive behavior. PMID:21144997
[Health alert management and emerging risk].
Pillonel, J
2010-12-01
Following health crisis that have occurred in the nineties (contaminated blood, mad cow, asbestos, etc.) and more recently those generated by the heat wave in 2003 or by emerging infectious pathogens (SARS, West Nile, Chikungunya, H5N1, H1N1…), a real health vigilance system has been progressively developed in France. After a brief historical overview of the health alert system, this article will give the guiding principles of its current organization in France and will present two examples of recent health alerts (Chikungunya in the Reunion Island in 2005-2006 and hepatitis A outbreak in the Côtes-d'Armor in August 2007), that have needed the implementation of preventive measures regarding the blood donor selection. These two examples have shown that the position of the alert in the French health vigilance system needs to be very close to the event. In that case, health alert is a very useful tool for decision making especially when measures have to be taken to prevent transfusion-transmitted pathogens. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
Earthquake Warning Performance in Vallejo for the South Napa Earthquake
NASA Astrophysics Data System (ADS)
Wurman, G.; Price, M.
2014-12-01
In 2002 and 2003, Seismic Warning Systems, Inc. installed first-generation QuakeGuardTM earthquake warning devices at all eight fire stations in Vallejo, CA. These devices are designed to detect the P-wave of an earthquake and initiate predetermined protective actions if the impending shaking is estimated at approximately Modifed Mercalli Intensity V or greater. At the Vallejo fire stations the devices were set up to sound an audio alert over the public address system and to command the equipment bay doors to open. In August 2014, after more than 11 years of operating in the fire stations with no false alarms, the five units that were still in use triggered correctly on the MW 6.0 South Napa earthquake, less than 16 km away. The audio alert sounded in all five stations, providing fire fighters with 1.5 to 2.5 seconds of warning before the arrival of the S-wave, and the equipment bay doors opened in three of the stations. In one station the doors were disconnected from the QuakeGuard device, and another station lost power before the doors opened completely. These problems highlight just a small portion of the complexity associated with realizing actionable earthquake warnings. The issues experienced in this earthquake have already been addressed in subsequent QuakeGuard product generations, with downstream connection monitoring and backup power for critical systems. The fact that the fire fighters in Vallejo were afforded even two seconds of warning at these epicentral distances results from the design of the QuakeGuard devices, which focuses on rapid false positive rejection and ground motion estimates. We discuss the performance of the ground motion estimation algorithms, with an emphasis on the accuracy and timeliness of the estimates at close epicentral distances.
47 CFR 10.340 - Digital television transmission towers retransmission capability.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Digital television transmission towers retransmission capability. 10.340 Section 10.340 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.340 Digital television transmission towers...
47 CFR 10.340 - Digital television transmission towers retransmission capability.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Digital television transmission towers retransmission capability. 10.340 Section 10.340 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.340 Digital television transmission towers...
47 CFR 10.340 - Digital television transmission towers retransmission capability.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Digital television transmission towers retransmission capability. 10.340 Section 10.340 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.340 Digital television transmission towers...
47 CFR 10.340 - Digital television transmission towers retransmission capability.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Digital television transmission towers retransmission capability. 10.340 Section 10.340 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.340 Digital television transmission towers...
Singh, Hardeep; Thomas, Eric J.; Sittig, Dean F.; Wilson, Lindsey; Espadas, Donna; Khan, Myrna M.; Petersen, Laura A.
2010-01-01
Background: Follow-up of abnormal outpatient laboratory test results is a major patient safety concern. Electronic medical records can potentially address this concern through automated notification. We examined whether automated notifications of abnormal laboratory results (alerts) in an integrated electronic medical record resulted in timely follow-up actions. Methods: We studied four alerts: hemoglobin A1c (HbA1c) ≥15%, positive hepatitis C antibody (HCV), prostate specific antigen (PSA) ≥15 ng/mL, and thyroid stimulating hormone (TSH) ≥ 15 mIU/L. An alert tracking system determined whether the alert was acknowledged (i.e. provider clicked on and opened the message) within two weeks of transmission; acknowledged alerts were considered read. Within 30 days of result transmission, record review and provider contact determined follow-up actions (e.g. patient contact, treatment etc.). Multivariable logistic regression models analyzed predictors for lack of timely follow-up. Results: Between May 2008 and December 2008, 78,158 tests (HbA1c, HCV, TSH and PSA) were performed, of which 1163 (1.48%) were transmitted as alerts; 10.2% of these (119/1163) were unacknowledged. Timely follow-up was lacking in 79 (6.8%) and was statistically not different for acknowledged and unacknowledged alerts (6.4% vs. 10.1%; p =.13). Two-hundred two alerts (17.4% of 1163) arose from unnecessarily ordered (redundant) tests. Alerts for a new versus known diagnosis were more likely to lack timely follow-up (OR: 7.35; 95% CI: 4.16-12.97) whereas alerts related to redundant tests were less likely to lack timely follow-up (OR: 0.24; 95% CI: 0.07-0.84). Conclusions: Safety concerns related to timely patient follow-up remain despite automated notification of non-life threatening abnormal laboratory results in the outpatient setting. PMID:20193832
NASA Runway Incursion Prevention System (RIPS) Dallas-Fort Worth Demonstration Performance Analysis
NASA Technical Reports Server (NTRS)
Cassell, Rick; Evers, Carl; Esche, Jeff; Sleep, Benjamin; Jones, Denise R. (Technical Monitor)
2002-01-01
NASA's Aviation Safety Program Synthetic Vision System project conducted a Runway Incursion Prevention System (RIPS) flight test at the Dallas-Fort Worth International Airport in October 2000. The RIPS research system includes advanced displays, airport surveillance system, data links, positioning system, and alerting algorithms to provide pilots with enhanced situational awareness, supplemental guidance cues, a real-time display of traffic information, and warnings of runway incursions. This report describes the aircraft and ground based runway incursion alerting systems and traffic positioning systems (Automatic Dependent Surveillance - Broadcast (ADS-B) and Traffic Information Service - Broadcast (TIS-B)). A performance analysis of these systems is also presented.
Bio-ALIRT biosurveillance detection algorithm evaluation.
Siegrist, David; Pavlin, J
2004-09-24
Early detection of disease outbreaks by a medical biosurveillance system relies on two major components: 1) the contribution of early and reliable data sources and 2) the sensitivity, specificity, and timeliness of biosurveillance detection algorithms. This paper describes an effort to assess leading detection algorithms by arranging a common challenge problem and providing a common data set. The objectives of this study were to determine whether automated detection algorithms can reliably and quickly identify the onset of natural disease outbreaks that are surrogates for possible terrorist pathogen releases, and do so at acceptable false-alert rates (e.g., once every 2-6 weeks). Historic de-identified data were obtained from five metropolitan areas over 23 months; these data included International Classification of Diseases, Ninth Revision (ICD-9) codes related to respiratory and gastrointestinal illness syndromes. An outbreak detection group identified and labeled two natural disease outbreaks in these data and provided them to analysts for training of detection algorithms. All outbreaks in the remaining test data were identified but not revealed to the detection groups until after their analyses. The algorithms established a probability of outbreak for each day's counts. The probability of outbreak was assessed as an "actual" alert for different false-alert rates. The best algorithms were able to detect all of the outbreaks at false-alert rates of one every 2-6 weeks. They were often able to detect for the same day human investigators had identified as the true start of the outbreak. Because minimal data exists for an actual biologic attack, determining how quickly an algorithm might detect such an attack is difficult. However, application of these algorithms in combination with other data-analysis methods to historic outbreak data indicates that biosurveillance techniques for analyzing syndrome counts can rapidly detect seasonal respiratory and gastrointestinal illness outbreaks. Further research is needed to assess the value of electronic data sources for predictive detection. In addition, simulations need to be developed and implemented to better characterize the size and type of biologic attack that can be detected by current methods by challenging them under different projected operational conditions.
Van Nuffel, A; Van De Gucht, T; Saeys, W; Sonck, B; Opsomer, G; Vangeyte, J; Mertens, K C; De Ketelaere, B; Van Weyenberg, S
2016-09-01
To tackle the high prevalence of lameness, techniques to monitor cow locomotion are being developed in order to detect changes in cows' locomotion due to lameness. Obviously, in such lameness detection systems, alerts should only respond to locomotion changes that are related to lameness. However, other environmental or cow factors can contribute to locomotion changes not related to lameness and hence, might cause false alerts. In this study the effects of wet surfaces, dark environment, age, production level, lactation and gestation stage on cow locomotion were investigated. Data was collected at Institute for Agricultural and Fisheries Research research farm (Melle, Belgium) during a 5-month period. The gait variables of 30 non-lame and healthy Holstein cows were automatically measured every day. In dark environments and on wet walking surfaces cows took shorter, more asymmetrical strides with less step overlap. In general, older cows had a more asymmetrical gait and they walked slower with more abduction. Lactation stage or gestation stage also showed significant association with asymmetrical and shorter gait and less step overlap probably due to the heavy calf in the uterus. Next, two lameness detection algorithms were developed to investigate the added value of environmental and cow data into detection models. One algorithm solely used locomotion variables and a second algorithm used the same locomotion variables and additional environmental and cow data. In the latter algorithm only age and lactation stage together with the locomotion variables were withheld during model building. When comparing the sensitivity for the detection of non-lame cows, sensitivity increased by 10% when the cow data was added in the algorithm (sensitivity was 70% and 80% for the first and second algorithm, respectively). Hence, the number of false alerts for lame cows that were actually non-lame, decreased. This pilot study shows that using knowledge on influencing factors on cow locomotion will help in reducing the number of false alerts for lameness detection systems under development. However, further research is necessary in order to better understand these and many other possible influencing factors (e.g. trimming, conformation) of non-lame and hence 'normal' locomotion in cows.
Cerreta, Michelle M; Furton, Kenneth G
2015-06-01
In recent years, the high frequency of illicit substance abuse reported in the United States has made the development of efficient and rapid detection methods important. Biological detectors, such as canines (Canis familiaris), are valuable tools for rapid, on-site identification of illicit substances. However, research indicates that in many cases canines do not alert to the contraband, but rather to the volatile organic compounds (VOCs) that are released from the contraband, referred to as the "active odor." In 2013, canine accuracy and reliability were challenged in the Supreme Court case, State of Florida v. Jardines. In this case, it was stated that if a canine alerts to the active odor, and not the contraband, the canine's accuracy and selectivity could be questioned, since many of these compounds have been found in common household products. Specifically, methyl benzoate, the active odor of cocaine, has been found to be the most abundant compound produced by snapdragon flowers. Therefore, the purpose of this study is to evaluate the odor profiles of various species of snapdragon flowers to assess how significantly methyl benzoate contributes to the total VOC profile or fragrance that is produced. Particularly, this study examines the VOCs released from newly grown snapdragon flowers and determines its potential at eliciting a false alert from specially trained detection canines. The ability of detection canines to differentiate between cocaine and snapdragon flowers was determined in order to validate the field accuracy and discrimination power of these detectors. An optimized method using headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry (HS-SPME/GC-MS) was used to test the different types and abundances of compounds generated from snapdragon flowers at various stages throughout the plants' life cycle. The results indicate that although methyl benzoate is present in the odor profile of snapdragon flowers, other compounds are present that contribute significantly, if not more, than that of methyl benzoate. Canine teams, from various police departments throughout South Florida, certified for narcotics detection, took part in this study. Two canine trials involving 21 canines teams were performed by exposing the teams to 4 different species of snapdragon flowers. Of the 21 canine teams tested, none alerted to the snapdragon flowers presented, while all (100%) alerted to real cocaine samples, the positive control. Notably, the results revealed that although methyl benzoate is produced by snapdragon flowers, certified narcotics detection canines can distinguish cocaine's odor profile from that of snapdragon flowers. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Purpose. 10.2 Section 10.2 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM General Information § 10.2 Purpose. The rules in this part establish the requirements for participation in the voluntary Commercial...
47 CFR 10.520 - Common audio attention signal.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Common audio attention signal. 10.520 Section 10.520 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Equipment Requirements § 10.520 Common audio attention signal. A Participating CMS Provider and equipment...
47 CFR 10.530 - Common vibration cadence.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Common vibration cadence. 10.530 Section 10.530 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Equipment Requirements § 10.530 Common vibration cadence. A Participating CMS Provider and equipment manufacturers may only...
47 CFR 10.510 - Call preemption prohibition.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Call preemption prohibition. 10.510 Section 10.510 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Equipment Requirements § 10.510 Call preemption prohibition. Devices marketed for public use under part 10...
47 CFR 10.11 - CMAS implementation timeline.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false CMAS implementation timeline. 10.11 Section 10.11 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM General Information § 10.11 CMAS implementation timeline. Notwithstanding anything in this part to the contrary, a...
47 CFR 10.500 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false General requirements. 10.500 Section 10.500 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Equipment Requirements § 10.500 General requirements. CMAS mobile device functionality is dependent on the capabilities of a...
Eye Can See for Miles and Miles.
ERIC Educational Resources Information Center
School Planning & Management, 2002
2002-01-01
Describes how a New Hampshire school system eliminated internal school vandalism and bomb threats, and reduced the number of false alarms, by using video security software (WebEyeAlert security solution) that is accessible via a variety of methods from remote locations. (Author/EV)
47 CFR 11.43 - National level participation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false National level participation. 11.43 Section 11.43 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT SYSTEM (EAS... national level EAS may submit a written request to the Chief, Public Safety and Homeland Security Bureau...
Code of Federal Regulations, 2010 CFR
2010-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Procurement Standards § 32.43 Competition. All... 32 National Defense 1 2010-07-01 2010-07-01 false Competition. 32.43 Section 32.43 National... free competition. The recipient shall be alert to organizational conflicts of interest as well as...
Code of Federal Regulations, 2010 CFR
2010-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Procurement Standards § 49.43 Competition. All... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Competition. 49.43... free competition. The recipient shall be alert to organizational conflicts of interest as well as...
Code of Federal Regulations, 2010 CFR
2010-07-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Procurement Standards § 30.43 Competition. All... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Competition. 30.43 Section 30.43... free competition. The recipient shall be alert to organizational conflicts of interest as well as...
Austrian, Jonathan S; Jamin, Catherine T; Doty, Glenn R; Blecker, Saul
2018-05-01
The purpose of this study was to determine whether an electronic health record-based sepsis alert system could improve quality of care and clinical outcomes for patients with sepsis. We performed a patient-level interrupted time series study of emergency department patients with severe sepsis or septic shock between January 2013 and April 2015. The intervention, introduced in February 2014, was a system of interruptive sepsis alerts triggered by abnormal vital signs or laboratory results. Primary outcomes were length of stay (LOS) and in-hospital mortality; other outcomes included time to first lactate and blood cultures prior to antibiotics. We also assessed sensitivity, positive predictive value (PPV), and clinician response to the alerts. Mean LOS for patients with sepsis decreased from 10.1 to 8.6 days (P < .001) following alert introduction. In adjusted time series analysis, the intervention was associated with a decreased LOS of 16% (95% CI, 5%-25%; P = .007, with significance of α = 0.006) and no change thereafter (0%; 95% CI, -2%, 2%). The sepsis alert system had no effect on mortality or other clinical or process measures. The intervention had a sensitivity of 80.4% and a PPV of 14.6%. Alerting based on simple laboratory and vital sign criteria was insufficient to improve sepsis outcomes. Alert fatigue due to the low PPV is likely the primary contributor to these results. A more sophisticated algorithm for sepsis identification is needed to improve outcomes.
Szabados, F; Michels, M; Kaase, M; Gatermann, S
2011-02-01
Recently, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been presented as a novel method for the direct identification of bacteria from positive blood culture bottles. The rate of the MALDI TOF MS-based identification in the present study from positive BacT/ALERT (bioMérieux, Marcy l'Etoile, France) blood culture bottles was 30%, which is far below the previously reported sensitivities using the BACTEC (Becton Dickinson, Franklin Lakes, NJ, USA) system. We also found evidence that the Biotyper algorithm did not identify a second pathogen in cases of positive BacT/ALERT blood culture bottles containing two different species. © 2010 The Authors. Journal Compilation © 2010 European Society of Clinical Microbiology and Infectious Diseases.
Real-time Automated Sampling of Electronic Medical Records Predicts Hospital Mortality
Khurana, Hargobind S.; Groves, Robert H.; Simons, Michael P.; Martin, Mary; Stoffer, Brenda; Kou, Sherri; Gerkin, Richard; Reiman, Eric; Parthasarathy, Sairam
2016-01-01
Background Real-time automated continuous sampling of electronic medical record data may expeditiously identify patients at risk for death and enable prompt life-saving interventions. We hypothesized that a real-time electronic medical record-based alert could identify hospitalized patients at risk for mortality. Methods An automated alert was developed and implemented to continuously sample electronic medical record data and trigger when at least two of four systemic inflammatory response syndrome criteria plus at least one of 14 acute organ dysfunction parameters was detected. The SIRS/OD alert was applied real-time to 312,214 patients in 24 hospitals and analyzed in two phases: training and validation datasets. Results In the training phase, 29,317 (18.8%) triggered the alert and 5.2% of such patients died whereas only 0.2% without the alert died (unadjusted odds ratio 30.1; 95% confidence interval [95%CI] 26.1, 34.5; P<0.0001). In the validation phase, the sensitivity, specificity, area under curve (AUC), positive and negative likelihood ratios for predicting mortality were 0.86, 0.82, 0.84, 4.9, and 0.16, respectively. Multivariate Cox-proportional hazard regression model revealed greater hospital mortality when the alert was triggered (adjusted Hazards Ratio 4.0; 95%CI 3.3, 4.9; P<0.0001). Triggering the alert was associated with additional hospitalization days (+3.0 days) and ventilator days (+1.6 days; P<0.0001). Conclusion An automated alert system that continuously samples electronic medical record-data can be implemented, has excellent test characteristics, and can assist in the real-time identification of hospitalized patients at risk for death. PMID:27019043
Incorporation of operator knowledge for improved HMDS GPR classification
NASA Astrophysics Data System (ADS)
Kennedy, Levi; McClelland, Jessee R.; Walters, Joshua R.
2012-06-01
The Husky Mine Detection System (HMDS) detects and alerts operators to potential threats observed in groundpenetrating RADAR (GPR) data. In the current system architecture, the classifiers have been trained using available data from multiple training sites. Changes in target types, clutter types, and operational conditions may result in statistical differences between the training data and the testing data for the underlying features used by the classifier, potentially resulting in an increased false alarm rate or a lower probability of detection for the system. In the current mode of operation, the automated detection system alerts the human operator when a target-like object is detected. The operator then uses data visualization software, contextual information, and human intuition to decide whether the alarm presented is an actual target or a false alarm. When the statistics of the training data and the testing data are mismatched, the automated detection system can overwhelm the analyst with an excessive number of false alarms. This is evident in the performance of and the data collected from deployed systems. This work demonstrates that analyst feedback can be successfully used to re-train a classifier to account for variable testing data statistics not originally captured in the initial training data.
ElarmS Earthquake Early Warning System 2016 Performance and New Research
NASA Astrophysics Data System (ADS)
Chung, A. I.; Allen, R. M.; Hellweg, M.; Henson, I. H.; Neuhauser, D. S.
2016-12-01
The ElarmS earthquake early warning system has been detecting earthquakes throughout California since 2007. It is one of the algorithms that contributes to the West Coast ShakeAlert, a prototype earthquake early warning system being developed for the US West Coast. ElarmS is also running in the Pacific Northwest, and in Israel, Chile, Turkey, and Peru in test mode. We summarize the performance of the ElarmS system over the past year and review some of the more problematic events that the system has encountered. During the first half of 2016 (2016-01-01 through 2016-07-21), ElarmS successfully alerted on all events with ANSS catalog magnitudes M>3 in the Los Angeles area. The mean alert time for these 9 events was just 4.84 seconds. In the San Francisco Bay Area, ElarmS detected 26 events with ANSS catalog magnitudes M>3. The alert times for these events is 9.12 seconds. The alert times are longer in the Bay Area than in the Los Angeles area due to the sparser network of stations in the Bay Area. 7 Bay Area events were not detected by ElarmS. These events occurred in areas where there is less dense station coverage. In addition, ElarmS sent alerts for 13 of the 16 moderately-sized (ANSS catalog magnitudes M>4) events that occurred throughout the state of California. One of those missed events was a M4.5 that occurred far offshore in the northernmost part of the state. The other two missed events occurred inland in regions with sparse station coverage. Over the past year, we have worked towards the implementation of a new filterbank teleseismic filter algorithm, which we will discuss. Other than teleseismic events, a significant cause of false alerts and severely mislocated events is spurious triggers being associated with triggers from a real earthquake. Here, we address new approaches to filtering out problematic triggers.
41 CFR 105-72.503 - Competition.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false Competition. 105-72.503 Section 105-72.503 Public Contracts and Property Management Federal Property Management Regulations System... practical, open and free competition. The recipient shall be alert to organizational conflicts of interest...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 45 Public Welfare 1 2011-10-01 2011-10-01 false Competition. 74.43 Section 74.43 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION UNIFORM ADMINISTRATIVE REQUIREMENTS FOR AWARDS... competition. The recipient shall be alert to organizational conflicts of interest as well as noncompetitive...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 1 2010-10-01 2010-10-01 false Competition. 74.43 Section 74.43 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION UNIFORM ADMINISTRATIVE REQUIREMENTS FOR AWARDS... competition. The recipient shall be alert to organizational conflicts of interest as well as noncompetitive...
14 CFR 1260.143 - Competition.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., Hospitals, and Other Non-Profit Organizations Procurement Standards § 1260.143 Competition. All procurement... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Competition. 1260.143 Section 1260.143... competition. The recipient shall be alert to organizational conflicts of interest as well as noncompetitive...
Code of Federal Regulations, 2010 CFR
2010-04-01
... NON-PROFIT ORGANIZATIONS Post-Award Requirements Procurement Standards § 84.43 Competition. All... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Competition. 84.43 Section 84.43... free competition. The recipient shall be alert to organizational conflicts of interest as well as...
NASA Astrophysics Data System (ADS)
Donovan, Amy; Ayala, Irasema Alcántara; Eiser, J. R.; Sparks, R. S. J.
2018-05-01
This paper presents data from an online survey carried out in Mexico from 2012 to 2014. The survey focussed on the risk to Mexico City from Popocatépetl, an active volcano 60 km from the city. During the time period, volcanic activity was variable, and the alert level changed accordingly. The survey showed that people surveyed at the higher alert level were generally more concerned about the volcano. Since these people were measured separately from those who responded at the lower alert level and yet self-reported on the same scale as more concerned, this provides a useful indicator that the raised alert level may be associated with higher risk perception, and that alert level systems act as boundary objects in the translation of scientific information. In general, trust in various groups was most strongly explained by the perceived knowledge of the groups, followed by their perceived motivation (whether or not they are viewed as working in society's interest), with accuracy a tertiary concern. Some respondents were anxious about false alarms—these people also tended to be concerned about scientific accuracy while those who favoured precaution tended to be more trusting. The perceived effectiveness of warning and evacuation plans was also a significant predictor for trust in official groups. In general, the results suggest that there are important links between trust, warning plans and the perceived motivation of particular groups as well as between trust and perceived knowledge.
VHF-FM Emergency Position Indicating Radio Beacon
DOT National Transportation Integrated Search
1978-10-01
This report describes the development and testing of an Emergency Position Indicating Radio Beacon (EPIRB) which operates on Channels 15 and 16 of the Maritime Mobile VHF Band. It provides functions necessary to ensure that distress alerting and loca...
Terrain Display Alternatives Assessment of Information Density and Alerting Strategies
DOT National Transportation Integrated Search
1998-04-01
Current technology makes it possible to display navigation and terrain information on electronic : screens in the cockpit. The conventions used for position and terrain information must be clearly : presented so pilots can maintain their positional a...
Mestas, Javier; Felsenstein, Susanna; Bard, Jennifer Dien
2014-11-01
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry is a fast and robust method for the identification of bacteria. In this study, we evaluate the performance of a laboratory-developed lysis method (LDT) for the rapid identification of bacteria from positive BacT/ALERT blood culture bottles. Of the 168 positive bottles tested, 159 were monomicrobial, the majority of which were Gram-positive organisms (61.0% versus 39.0%). Using a cut-off score of ≥1.7, 80.4% of the organisms were correctly identified to the species level, and the identification rate of Gram-negative organisms (90.3%) was found to be significantly greater than that of Gram-positive organisms (78.4%). The simplicity and cost-effectiveness of the LDT enable it to be fully integrated into the routine workflow of the clinical microbiology laboratory, allowing for rapid identification of Gram-positive and Gram-negative bacteria within an hour of blood culture positivity. Copyright © 2014 Elsevier Inc. All rights reserved.
Online Conditional Outlier Detection in Nonstationary Time Series
Liu, Siqi; Wright, Adam; Hauskrecht, Milos
2017-01-01
The objective of this work is to develop methods for detecting outliers in time series data. Such methods can become the key component of various monitoring and alerting systems, where an outlier may be equal to some adverse condition that needs human attention. However, real-world time series are often affected by various sources of variability present in the environment that may influence the quality of detection; they may (1) explain some of the changes in the signal that would otherwise lead to false positive detections, as well as, (2) reduce the sensitivity of the detection algorithm leading to increase in false negatives. To alleviate these problems, we propose a new two-layer outlier detection approach that first tries to model and account for the nonstationarity and periodic variation in the time series, and then tries to use other observable variables in the environment to explain any additional signal variation. Our experiments on several data sets in different domains show that our method provides more accurate modeling of the time series, and that it is able to significantly improve outlier detection performance. PMID:29644345
Online Conditional Outlier Detection in Nonstationary Time Series.
Liu, Siqi; Wright, Adam; Hauskrecht, Milos
2017-05-01
The objective of this work is to develop methods for detecting outliers in time series data. Such methods can become the key component of various monitoring and alerting systems, where an outlier may be equal to some adverse condition that needs human attention. However, real-world time series are often affected by various sources of variability present in the environment that may influence the quality of detection; they may (1) explain some of the changes in the signal that would otherwise lead to false positive detections, as well as, (2) reduce the sensitivity of the detection algorithm leading to increase in false negatives. To alleviate these problems, we propose a new two-layer outlier detection approach that first tries to model and account for the nonstationarity and periodic variation in the time series, and then tries to use other observable variables in the environment to explain any additional signal variation. Our experiments on several data sets in different domains show that our method provides more accurate modeling of the time series, and that it is able to significantly improve outlier detection performance.
Application of the PageRank Algorithm to Alarm Graphs
NASA Astrophysics Data System (ADS)
Treinen, James J.; Thurimella, Ramakrishna
The task of separating genuine attacks from false alarms in large intrusion detection infrastructures is extremely difficult. The number of alarms received in such environments can easily enter into the millions of alerts per day. The overwhelming noise created by these alarms can cause genuine attacks to go unnoticed. As means of highlighting these attacks, we introduce a host ranking technique utilizing Alarm Graphs. Rather than enumerate all potential attack paths as in Attack Graphs, we build and analyze graphs based on the alarms generated by the intrusion detection sensors installed on a network. Given that the alarms are predominantly false positives, the challenge is to identify, separate, and ideally predict future attacks. In this paper, we propose a novel approach to tackle this problem based on the PageRank algorithm. By elevating the rank of known attackers and victims we are able to observe the effect that these hosts have on the other nodes in the Alarm Graph. Using this information we are able to discover previously overlooked attacks, as well as defend against future intrusions.
Circadian rhythms in human performance and mood under constant conditions
NASA Technical Reports Server (NTRS)
Monk, T. H.; Buysse, D. J.; Reynolds, C. F. 3rd; Berga, S. L.; Jarrett, D. B.; Begley, A. E.; Kupfer, D. J.
1997-01-01
This study explored the relationship between circadian performance rhythms and rhythms in rectal temperature, plasma cortisol, plasma melatonin, subjective alertness and well-being. Seventeen healthy young adults were studied under 36 h of 'unmasking' conditions (constant wakeful bedrest, temporal isolation, homogenized 'meals') during which rectal temperatures were measured every minute, and plasma cortisol and plasma melatonin measured every 20 min. Hourly subjective ratings of global vigour (alertness) and affect (well-being) were obtained followed by one of two performance batteries. On odd-numbered hours performance (speed and accuracy) of serial search, verbal reasoning and manual dexterity tasks was assessed. On even-numbered hours, performance (% hits, response speed) was measured at a 25-30 min visual vigilance task. Performance of all tasks (except search accuracy) showed a significant time of day variation usually with a nocturnal trough close to the trough in rectal temperature. Performance rhythms appeared not to reliably differ with working memory load. Within subjects, predominantly positive correlations emerged between good performance and higher temperatures and better subjective alertness; predominantly negative correlations between good performance and higher plasma levels of cortisol and melatonin. Temperature and cortisol rhythms correlated with slightly more performance measures (5/7) than did melatonin rhythms (4/7). Global vigour correlated about as well with performance (5/7) as did temperature, and considerably better than global affect (1/7). In conclusion: (1) between-task heterogeneity in circadian performance rhythms appeared to be absent when the sleep/wake cycle was suspended; (2) temperature (positively), cortisol and melatonin (negatively) appeared equally good as circadian correlates of performance, and (3) subjective alertness correlated with performance rhythms as well as (but not better than) body temperature, suggesting that performance rhythms were not directly mediated by rhythms in subjective alertness.
Akhloufi, H; Hulscher, M; van der Hoeven, C P; Prins, J M; van der Sijs, H; Melles, D C; Verbon, A
2018-04-26
To evaluate a clinical decision support system (CDSS) based on consensus-based intravenous to oral switch criteria, which identifies intravenous to oral switch candidates. A three-step evaluation study of a stand-alone CDSS with electronic health record interoperability was performed at the Erasmus University Medical Centre in the Netherlands. During the first step, we performed a technical validation. During the second step, we determined the sensitivity, specificity, negative predictive value and positive predictive value in a retrospective cohort of all hospitalized adult patients starting at least one therapeutic antibacterial drug between 1 and 16 May 2013. ICU, paediatric and psychiatric wards were excluded. During the last step the clinical relevance and usefulness was prospectively assessed by reports to infectious disease specialists. An alert was considered clinically relevant if antibiotics could be discontinued or switched to oral therapy at the time of the alert. During the first step, one technical error was found. The second step yielded a positive predictive value of 76.6% and a negative predictive value of 99.1%. The third step showed that alerts were clinically relevant in 53.5% of patients. For 43.4% it had already been decided to discontinue or switch the intravenous antibiotics by the treating physician. In 10.1%, the alert resulted in advice to change antibiotic policy and was considered useful. This prospective cohort study shows that the alerts were clinically relevant in >50% (n = 449) and useful in 10% (n = 85). The CDSS needs to be evaluated in hospitals with varying activity of infectious disease consultancy services as this probably influences usefulness.
Kim, Dae Shik; Emerson, Robert Wall; Naghshineh, Koorosh; Pliskow, Jay; Myers, Kyle
2012-05-01
This study examined the effect of adding an artificially generated alert sound to a quiet vehicle on its detectability and localizability with 15 visually impaired adults. When starting from a stationary position, the hybrid electric vehicle with an alert sound was significantly more quickly and reliably detected than either the identical vehicle without such added sound or the comparable internal combustion engine vehicle. However, no significant difference was found between the vehicles in respect to how accurately the participants could discriminate the path of a given vehicle (straight vs. right turn). These results suggest that adding an artificial sound to a hybrid electric vehicle may help reduce delay in street crossing initiation by a blind pedestrian, but the benefit of such alert sound may not be obvious in determining whether the vehicle in his near parallel lane proceeds straight through the intersection or turns right in front of him.
Kim, Dae Shik; Emerson, Robert Wall; Naghshineh, Koorosh; Pliskow, Jay; Myers, Kyle
2012-01-01
This study examined the effect of adding an artificially generated alert sound to a quiet vehicle on its detectability and localizability with 15 visually impaired adults. When starting from a stationary position, the hybrid electric vehicle with an alert sound was significantly more quickly and reliably detected than either the identical vehicle without such added sound or the comparable internal combustion engine vehicle. However, no significant difference was found between the vehicles in respect to how accurately the participants could discriminate the path of a given vehicle (straight vs. right turn). These results suggest that adding an artificial sound to a hybrid electric vehicle may help reduce delay in street crossing initiation by a blind pedestrian, but the benefit of such alert sound may not be obvious in determining whether the vehicle in his near parallel lane proceeds straight through the intersection or turns right in front of him. PMID:22707841
Results of an independent evaluation of Project ALERT delivered in schools by Cooperative Extension.
St Pierre, Tena L; Osgood, D Wayne; Mincemoyer, Claudia C; Kaltreider, D Lynne; Kauh, Tina J
2005-12-01
Reported are results of an independent effectiveness study of the Project ALERT drug prevention program implemented in eight Pennsylvania middle schools by outside program leaders employed by Cooperative Extension. In this randomized, 2-cohort longitudinal evaluation, 1,649 seventh-grade students completed a pretest and four waves of posttests over the 2-year program and 1-year follow-up. Project ALERT's effectiveness was tested through a 3-level hierarchical linear model. Analyses failed to yield any positive effects for substance use or mediators for use in the adult or teen-assisted delivery of the curriculum. An extensive set of additional analyses detected no differential program effects by student risk level, gender, school, or level of implementation quality. Potential explanations for outcomes relative to Project ALERT's original effectiveness trial are discussed, as well as implications for future research, including the need to conduct independent effectiveness studies of previously validated programs in a variety of contexts.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Basis. 10.1 Section 10.1 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM General Information § 10.1 Basis... 109-347, Titles I through III of the Communications Act of 1934, as amended, and Executive Order 13407...
47 CFR 10.350 - WEA Testing requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false WEA Testing requirements. 10.350 Section 10.350 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.350 WEA Testing requirements. This section specifies the testing that will be required, no later than the...
47 CFR 10.350 - WEA Testing requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false WEA Testing requirements. 10.350 Section 10.350 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.350 WEA Testing requirements. This section specifies the testing that will be required, no later than the...
47 CFR 10.420 - Message elements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Message elements. 10.420 Section 10.420... Requirements § 10.420 Message elements. A CMAS Alert Message processed by a Participating CMS Provider shall include five mandatory CAP elements—Event Type; Area Affected; Recommended Action; Expiration Time (with...
47 CFR 10.420 - Message elements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Message elements. 10.420 Section 10.420... Requirements § 10.420 Message elements. A CMAS Alert Message processed by a Participating CMS Provider shall include five mandatory CAP elements—Event Type; Area Affected; Recommended Action; Expiration Time (with...
47 CFR 10.420 - Message elements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Message elements. 10.420 Section 10.420... § 10.420 Message elements. A WEA Alert Message processed by a Participating CMS Provider shall include five mandatory CAP elements—Event Type; Area Affected; Recommended Action; Expiration Time (with time...
47 CFR 10.420 - Message elements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Message elements. 10.420 Section 10.420... § 10.420 Message elements. A WEA Alert Message processed by a Participating CMS Provider shall include five mandatory CAP elements—Event Type; Area Affected; Recommended Action; Expiration Time (with time...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Basis. 10.1 Section 10.1 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM General Information § 10.1 Basis... Response Network Act, Title VI of the Security and Accountability for Every Port Act of 2006, Public Law...
41 CFR 105-72.503 - Competition.
Code of Federal Regulations, 2010 CFR
2010-07-01
... NON-PROFIT ORGANIZATIONS 72.50-Post-Award Requirements/Procurement Standards § 105-72.503 Competition... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Competition. 105-72.503... practical, open and free competition. The recipient shall be alert to organizational conflicts of interest...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Network Act, Title VI of the Security and Accountability for Every Port Act of 2006, Public Law 109-347... 47 Telecommunication 1 2013-10-01 2013-10-01 false Basis. 10.1 Section 10.1 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS General Information § 10.1 Basis. The...
Code of Federal Regulations, 2014 CFR
2014-10-01
... Network Act, Title VI of the Security and Accountability for Every Port Act of 2006, Public Law 109-347... 47 Telecommunication 1 2014-10-01 2014-10-01 false Basis. 10.1 Section 10.1 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS General Information § 10.1 Basis. The...
Continuous Glucose Monitoring Enables the Detection of Losses in Infusion Set Actuation (LISAs)
Howsmon, Daniel P.; Cameron, Faye; Baysal, Nihat; Ly, Trang T.; Forlenza, Gregory P.; Maahs, David M.; Buckingham, Bruce A.; Hahn, Juergen; Bequette, B. Wayne
2017-01-01
Reliable continuous glucose monitoring (CGM) enables a variety of advanced technology for the treatment of type 1 diabetes. In addition to artificial pancreas algorithms that use CGM to automate continuous subcutaneous insulin infusion (CSII), CGM can also inform fault detection algorithms that alert patients to problems in CGM or CSII. Losses in infusion set actuation (LISAs) can adversely affect clinical outcomes, resulting in hyperglycemia due to impaired insulin delivery. Prolonged hyperglycemia may lead to diabetic ketoacidosis—a serious metabolic complication in type 1 diabetes. Therefore, an algorithm for the detection of LISAs based on CGM and CSII signals was developed to improve patient safety. The LISA detection algorithm is trained retrospectively on data from 62 infusion set insertions from 20 patients. The algorithm collects glucose and insulin data, and computes relevant fault metrics over two different sliding windows; an alarm sounds when these fault metrics are exceeded. With the chosen algorithm parameters, the LISA detection strategy achieved a sensitivity of 71.8% and issued 0.28 false positives per day on the training data. Validation on two independent data sets confirmed that similar performance is seen on data that was not used for training. The developed algorithm is able to effectively alert patients to possible infusion set failures in open-loop scenarios, with limited evidence of its extension to closed-loop scenarios. PMID:28098839
Continuous Glucose Monitoring Enables the Detection of Losses in Infusion Set Actuation (LISAs).
Howsmon, Daniel P; Cameron, Faye; Baysal, Nihat; Ly, Trang T; Forlenza, Gregory P; Maahs, David M; Buckingham, Bruce A; Hahn, Juergen; Bequette, B Wayne
2017-01-15
Reliable continuous glucose monitoring (CGM) enables a variety of advanced technology for the treatment of type 1 diabetes. In addition to artificial pancreas algorithms that use CGM to automate continuous subcutaneous insulin infusion (CSII), CGM can also inform fault detection algorithms that alert patients to problems in CGM or CSII. Losses in infusion set actuation (LISAs) can adversely affect clinical outcomes, resulting in hyperglycemia due to impaired insulin delivery. Prolonged hyperglycemia may lead to diabetic ketoacidosis-a serious metabolic complication in type 1 diabetes. Therefore, an algorithm for the detection of LISAs based on CGM and CSII signals was developed to improve patient safety. The LISA detection algorithm is trained retrospectively on data from 62 infusion set insertions from 20 patients. The algorithm collects glucose and insulin data, and computes relevant fault metrics over two different sliding windows; an alarm sounds when these fault metrics are exceeded. With the chosen algorithm parameters, the LISA detection strategy achieved a sensitivity of 71.8% and issued 0.28 false positives per day on the training data. Validation on two independent data sets confirmed that similar performance is seen on data that was not used for training. The developed algorithm is able to effectively alert patients to possible infusion set failures in open-loop scenarios, with limited evidence of its extension to closed-loop scenarios.
Allen, A P; Smith, A P
2012-10-01
Previous research has indicated that chewing gum enhances reported alertness, but has variable effects on attention. Demand characteristics may explain these effects. The current study investigated the effects of gum and demand characteristics on attention and reported mood over time. Participants completed measures of mood and attention, with and without chewing gum. To manipulate demand characteristics, they were told that the hypothesised effect of gum was either positive or negative, or no hypothesis was mentioned. Attitudes towards gum were assessed pre- and post-manipulation. Gum increased reported alertness; this effect was only significant for positive and neutral demand characteristics. Vigilance accuracy was reduced for chewing gum, but only in the fourth minute of the task, and gum reduced focussed attention accuracy, but only for the first 64 trials. Demand characteristics did not moderate time-on-task effects. Gum improved selective attention. A positive effect on response organisation was observed; this was significant when demand characteristics and pre-test attitudes to gum were both negative. The results suggest that demand characteristics moderate effects on self-reported alertness and response organisation, but cannot explain time-on-task effects or variable main effects on other aspects of attention. Copyright © 2012 Elsevier Ltd. All rights reserved.
Ayala, Jessica; Simons, Kelsie; Kerrigan, Sarah
2009-01-01
The purpose of this study was to determine whether non-alcoholic energy drinks could result in positive "alcohol alerts" based on transdermal alcohol concentration (TAC) using a commercially available electrochemical monitoring device. Eleven energy drinks were quantitatively assayed for both ethanol and caffeine. Ethanol concentrations for all of the non-alcoholic energy drinks ranged in concentration from 0.03 to 0.230% (w/v) and caffeine content per 8-oz serving ranged from 65 to 126 mg. A total of 15 human subjects participated in the study. Subjects consumed between 6 and 8 energy drinks over an 8-h period. The SCRAM II monitoring device was used to determine TACs every 30 min before, during, and after the study. None of the subjects produced TAC readings that resulted in positive "alcohol alerts". TAC measurements for all subjects before, during and after the energy drink study period (16 h total) were <0.02% (w/v). Subjects in the study consumed a quantity of non-alcoholic energy drink that greatly exceeds what would be considered typical. Based on these results, it appears that energy drink consumption is an unlikely explanation for elevated TACs that might be identified as potential drinking episodes or "alcohol alerts" using this device.
A model for anomaly classification in intrusion detection systems
NASA Astrophysics Data System (ADS)
Ferreira, V. O.; Galhardi, V. V.; Gonçalves, L. B. L.; Silva, R. C.; Cansian, A. M.
2015-09-01
Intrusion Detection Systems (IDS) are traditionally divided into two types according to the detection methods they employ, namely (i) misuse detection and (ii) anomaly detection. Anomaly detection has been widely used and its main advantage is the ability to detect new attacks. However, the analysis of anomalies generated can become expensive, since they often have no clear information about the malicious events they represent. In this context, this paper presents a model for automated classification of alerts generated by an anomaly based IDS. The main goal is either the classification of the detected anomalies in well-defined taxonomies of attacks or to identify whether it is a false positive misclassified by the IDS. Some common attacks to computer networks were considered and we achieved important results that can equip security analysts with best resources for their analyses.
Performance of two blood culture systems to detect anaerobic bacteria. Is there any difference?
Mueller-Premru, Manica; Jeverica, Samo; Papst, Lea; Nagy, Elisabeth
2017-06-01
We studied the performance characteristics of two blood culture (BC) bottles/systems, (i) BacT/ALERT-FN Plus/3D (bioMérieux, Marcy l'Étoile, France) and (ii) BACTEC-Lytic/9000 (Becton Dickinson, Sparks, USA) for detection of growth and time-to-positivity (TTP) against a balanced and diverse collection of anaerobic bacterial strains (n = 48) that included reference strains (n = 19) and clinical isolates (n = 29) of 32 species (15 Gram-negative and 17 Gram-positive). Standard suspension of bacteria was inoculated to each bottle in duplicates and incubated in the corresponding system. Overall, 62.5% (n = 30) of strains were detected by both BC bottle types. Comparing the two, 70.8% (n = 34) and 79.2% (n = 38) of strains were detected by BacT/ALERT-FN Plus and BACTEC-Lytic bottles, respectively (p = 0.38). Among Gram-negative anaerobes (n = 25) the detection rate was 76.0% (n = 19) vs. 92.0% (n = 23) (p = 0.22), respectively. Among Gram-positive anaerobes (n = 23) the detection rate was 65.2% (n = 15) in both bottles (p = 1). The average TTP per bottle was calculated only for the strains detected by both systems (n = 30) and was 40.85 h and 28.08 h for BacT/ALERT-FN Plus and BACTEC-Lytic, respectively (p < 0.001). The mean difference was 12.76 h (95% CI: 6.21-19-31 h). Six anaerobic strains were not detected by any system, including Gram-negative Porphyromonas gingivalis, and five Gram-positive strains: Finegoldia magna, Peptostreptococcus anaerobius, Propionibacterium acnes, Clostridium novyi and Clostridium clostridioforme. Furthermore, Eggerthella lenta and Prevotella bivia were detected only by BacT/ALERT-FN Plus, while Prevotella disiens and Prevotella intermedia were detected only by BACTEC-Lytic bottles. There were no major differences in detection rate among clinical and reference strains. Anaerobic bacteria represent a minority of BC isolates, however, far from ideal detection rate was observed in this study for both tested bottle/system combinations. Nevertheless, in those cases where both gave positive signal, BACTEC-Lytic was superior to BacT/ALERT FN Plus with 12.76 h shorter mean TTP. Improvements of media in blood culture bottles available for detection of anaerobes are warranted. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
47 CFR 11.19 - EAS Non-participating National Authorization Letter.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false EAS Non-participating National Authorization Letter. 11.19 Section 11.19 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT... level EAS. It states that the EAS Participant has agreed to go off the air or discontinue programming on...
47 CFR 11.19 - EAS Non-participating National Authorization Letter.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false EAS Non-participating National Authorization Letter. 11.19 Section 11.19 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT... level EAS. It states that the EAS Participant has agreed to go off the air or discontinue programming on...
47 CFR 11.14 - Primary Entry Point (PEP) System.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Primary Entry Point (PEP) System. 11.14 Section 11.14 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT SYSTEM (EAS) General § 11.14 Primary Entry Point (PEP) System. The PEP system is a nationwide network of broadcast...
47 CFR 11.14 - Primary Entry Point (PEP) System.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Primary Entry Point (PEP) System. 11.14 Section 11.14 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT SYSTEM (EAS) General § 11.14 Primary Entry Point (PEP) System. The PEP system is a nationwide network of broadcast...
16 CFR 1130.1 - Purpose, scope, and effective date.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Purpose, scope, and effective date. 1130.1..., scope, and effective date. (a) Purpose. This part prescribes a consumer product safety rule establishing... to improve the effectiveness of recalls of, and safety alerts regarding, such products. (b) Scope...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Désert, Jean-Michel; Brown, Timothy M.; Charbonneau, David
NASA’s Kepler mission has provided several thousand transiting planet candidates during the 4 yr of its nominal mission, yet only a small subset of these candidates have been confirmed as true planets. Therefore, the most fundamental question about these candidates is the fraction of bona fide planets. Estimating the rate of false positives of the overall Kepler sample is necessary to derive the planet occurrence rate. We present the results from two large observational campaigns that were conducted with the Spitzer Space Telescope during the the Kepler mission. These observations are dedicated to estimating the false positive rate (FPR) amongmore » the Kepler candidates. We select a sub-sample of 51 candidates, spanning wide ranges in stellar, orbital, and planetary parameter space, and we observe their transits with Spitzer at 4.5 μm. We use these observations to measures the candidate’s transit depths and infrared magnitudes. An authentic planet produces an achromatic transit depth (neglecting the modest effect of limb darkening). Conversely a bandpass-dependent depth alerts us to the potential presence of a blending star that could be the source of the observed eclipse: a false positive scenario. For most of the candidates (85%), the transit depths measured with Kepler are consistent with the transit depths measured with Spitzer as expected for planetary objects, while we find that the most discrepant measurements are due to the presence of unresolved stars that dilute the photometry. The Spitzer constraints on their own yield FPRs between 5% and depending on the Kepler Objects of Interest. By considering the population of the Kepler field stars, and by combining follow-up observations (imaging) when available, we find that the overall FPR of our sample is low. The measured upper limit on the FPR of our sample is 8.8% at a confidence level of 3σ. This observational result, which uses the achromatic property of planetary transit signals that is not investigated by the Kepler observations, provides an independent indication that Kepler’s FPR is low.« less
Douglas flight deck design philosophy
NASA Technical Reports Server (NTRS)
Oldale, Paul
1990-01-01
The systems experience gained from 17 years of DC-10 operation was used during the design of the MD-11 to automate system operation and reduce crew workload. All functions, from preflight to shutdown at the termination of flight, require little input from the crew. The MD-11 aircraft systems are monitored for proper operation by the Aircraft Systems Controllers (ASC). In most cases, system reconfiguration as a result of a malfunction is automated. Manual input is required for irreversible actions such as engine shutdown, fuel dump, fire agent discharge, or Integrated Drive Generator (IDG) disconnect. During normal operations, when the cockpit is configured for flight, all annunciators on the overhead panel will be extinguished. This Dark Cockpit immediately confirms to the crew that the panels are correctly configured and that no abnormalities are present. Primary systems annunciations are shown in text on the Alert Area of the Engine and Alert Display (EAD). This eliminates the need to scan the overhead. The MD-11 aircraft systems can be manually controlled from the overhead area of the cockpit. The center portion of the overhead panel is composed of the primary aircraft systems panels, which include FUEL, AIR, Electrical (ELEC) and Hydraulic (HYD) systems, which are easily accessible from both flight crew positions. Each Aircraft Systems Controller (ASC) has two automatic channels and a manual mode. All rectangular lights are annunciators. All square lights are combined switches and annunciators called switch/lights. Red switch/lights on the overhead (Level 3 alerts) are for conditions requiring immediate crew action. Amber (Level 2 or Level 1 alerts) indicates a fault or switch out of position requiring awareness or crew interaction. Overhead switches used in normal operating conditions will illuminate blue when in use (Level 0 alerts) such as WING ANTI-ICE - ON. An overhead switch/light with BLACK LETTERING on an amber or red background indicates a system failure and that crew interaction is required. A switch/light with blue or amber lettering and a BLACK BACKGROUND indicates a switch out of normal position and that crew action is necessary only if the system is in manual operation.
Self-Activating System and Method for Alerting When an Object or a Person is Left Unattended
NASA Technical Reports Server (NTRS)
Edwards, William Christopher (Inventor); Mack, Terry L. (Inventor); Modlin, Edward A. (Inventor)
2004-01-01
A system and method uses a wireless tether comprising a transmitter and a receiver to alert a caregiver that an object or person has been left unattended. A detector Senses the presence of the object, usually a child, located in a position such as a safety seat. The detector couples to the transmitter, which is located near the object. The transmitter transmits at least one wireless signal when the object is in the position. The receiver, which is remotely located from the transmitter, senses the at least one signal as long as the receiver is within a prescribed range of transmission. By performing a timing function, the receiver monitors the proximity of the caregiver, who maintains possession of the receiver, to the transmitter. The system communicates an alarm to the caregiver when the caregiver ventures outside the range of transmission without having removed the object/child from the position.
Self-activating System and Method for Alerting When an Object or a Person is Left Unattended
NASA Technical Reports Server (NTRS)
Edwards, William C. (Inventor); Mack, Terry L. (Inventor); Modlin, Edward A. (Inventor)
2006-01-01
A system and method use a wireless tether comprising a transmitter and a receiver to alert a caregiver that an object has been left unattended. A detector senses the presence of the object, usually a child, located in a position such as a safety seat. The detector is operatively coupled to the transmitter. which is located near the object. The transmitter transmits at least one wireless signal when the object is in the position. The receiver, which is remotely located from the transmitter, senses at least one signal as long as the receiver is within a prescribed range of transmission. By performing a timing function, the receiver monitors the proximity of the caregiver, who maintains possession of the receiver, to the transmitter. The system communicates an alarm to the caregiver when the caregiver ventures outside the range of transmission without having removed the object from the position.
Correlated colour temperature of morning light influences alertness and body temperature.
Te Kulve, Marije; Schlangen, Luc; Schellen, Lisje; Souman, Jan L; van Marken Lichtenbelt, Wouter
2018-03-01
Though several studies have reported human alertness to be affected by the intensity and spectral composition of ambient light, the mechanism behind this effect is still largely unclear, especially for daytime exposure. Alerting effects of nocturnal light exposure are correlated with melatonin suppression, but melatonin levels are generally low during the day. The aim of this study was to explore the alerting effect of light in the morning for different correlated colour temperature (CCT) values, as well as its interaction with ambient temperature. Body temperature and perceived comfort were included in the study as possible mediating factors. In a randomized crossover design, 16 healthy females participated in two sessions, once under 2700K and once under 6500K light (both 55lx). Each session consisted of a baseline, a cool, a neutral and a warm thermal environment. Alertness as measured in a reaction time task was lower for the 6500K exposure, while subjective sleepiness was not affected by CCT. Also, core body temperature was higher under 6500K. Skin temperature parameters and perceived comfort were positively correlated with subjective sleepiness. Reaction time correlated with heat loss, but this association did not explain why the reaction time was improved for 2700K. Copyright © 2017 Elsevier Inc. All rights reserved.
Warning systems in risk management.
Paté-Cornell, M E
1986-06-01
A method is presented here that allows probabilistic evaluation and optimization of warning systems, and comparison of their performance and cost-effectiveness with those of other means of risk management. The model includes an assessment of the signals, and of human response, given the memory that people have kept of the quality of previous alerts. The trade-off between the rate of false alerts and the length of the lead time is studied to account for the long-term effects of "crying wolf" and the effectiveness of emergency actions. An explicit formulation of the system's benefits, including inputs from a signal model, a response model, and a consequence model, is given to allow optimization of the warning threshold and of the system's sensitivity.
49 CFR 398.4 - Driving of motor vehicles.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 5 2013-10-01 2013-10-01 false Driving of motor vehicles. 398.4 Section 398.4... his/her ability or alertness is so impaired through fatigue, illness, or any other cause as to make it... result of the displacement or falling of such articles. (5) Maximum passengers on motor vehicles. No...
49 CFR 398.4 - Driving of motor vehicles.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Driving of motor vehicles. 398.4 Section 398.4... his/her ability or alertness is so impaired through fatigue, illness, or any other cause as to make it... result of the displacement or falling of such articles. (5) Maximum passengers on motor vehicles. No...
49 CFR 398.4 - Driving of motor vehicles.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 5 2012-10-01 2012-10-01 false Driving of motor vehicles. 398.4 Section 398.4... his/her ability or alertness is so impaired through fatigue, illness, or any other cause as to make it... result of the displacement or falling of such articles. (5) Maximum passengers on motor vehicles. No...
49 CFR 398.4 - Driving of motor vehicles.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 5 2014-10-01 2014-10-01 false Driving of motor vehicles. 398.4 Section 398.4... his/her ability or alertness is so impaired through fatigue, illness, or any other cause as to make it... result of the displacement or falling of such articles. (5) Maximum passengers on motor vehicles. No...
49 CFR 398.4 - Driving of motor vehicles.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Driving of motor vehicles. 398.4 Section 398.4... his/her ability or alertness is so impaired through fatigue, illness, or any other cause as to make it... result of the displacement or falling of such articles. (5) Maximum passengers on motor vehicles. No...
Yoo, In Young; Chun, Sejong; Song, Dong Joon; Huh, Hee Jae; Lee, Nam Yong
2016-11-01
We compared the BacT/Alert system FAN and FAN Plus media to conventional media for culturing cerebrospinal fluid (CSF) with 2,545 samples. FAN/FAN Plus bottles showed better performance for isolating microorganisms in CSF than conventional media (positive rate, 7.2% [182/2,545] versus 3.1% [80/2,545]). The incremental recovery rate of Cryptococcus neoformans from FAN Plus bottles was higher than that from FAN bottles. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Predicting Sepsis Risk Using the "Sniffer" Algorithm in the Electronic Medical Record.
Olenick, Evelyn M; Zimbro, Kathie S; DʼLima, Gabrielle M; Ver Schneider, Patricia; Jones, Danielle
The Sepsis "Sniffer" Algorithm (SSA) has merit as a digital sepsis alert but should be considered an adjunct to versus an alternative for the Nurse Screening Tool (NST), given lower specificity and positive predictive value. The SSA reduced the risk of incorrectly categorizing patients at low risk for sepsis, detected sepsis high risk in half the time, and reduced redundant NST screens by 70% and manual screening hours by 64% to 72%. Preserving nurse hours expended on manual sepsis alerts may translate into time directed toward other patient priorities.
NASA Technical Reports Server (NTRS)
Callantine, Todd J.; Bienert, Nancy; Borade, Abhay; Gabriel, Conrad; Gujral, Vimmy; Jobe, Kim; Martin, Lynne; Omar, Faisal; Prevot, Thomas; Mercer, Joey
2016-01-01
A human-in-the-loop simulation study addressed terminal-area controller-workstation interface variations for interoperability between three new capabilities being introduced by the FAA. The capabilities are Terminal Sequencing and Spacing (TSAS), Automated Terminal Proximity Alert (ATPA), and wake-separation recategorization, or 'RECAT.' TSAS provides controllers with Controller-Managed Spacing (CMS) tools, including slot markers, speed advisories, and early/late indications, together with runway assignments and sequence numbers. ATPA provides automatic monitor, warning, and alert cones to inform controllers about spacing between aircraft on approach. ATPA cones are sized according to RECAT, an improved method of specifying wake-separation standards. The objective of the study was to identify potential issues and provide recommendations for integrating TSAS with ATPA and RECAT. Participants controlled arrival traffic under seven different display configurations, then tested an 'exploratory' configuration developed with participant input. All the display conditions were workable and acceptable, but controllers strongly preferred having the CMS tools available on Feeder positions, and both CMS tools and ATPA available on Final positions. Controllers found the integrated systems favorable and liked being able to tailor configurations to individual preferences.
... in the big toe during use (walking, standing, bending, etc.) Pain and stiffness aggravated by cold, damp ... ps.position.alert.message}} Getting your location, one moment... Please enter a 5-digit zip code. Please ...
Hazards in Motion: Development of Mobile Geofences for Use in Logging Safety
Zimbelman, Eloise G.; Keefe, Robert F.; Strand, Eva K.; Kolden, Crystal A.; Wempe, Ann M.
2017-01-01
Logging is one of the most hazardous occupations in the United States. Real-time positioning that uses global navigation satellite system (GNSS) technology paired with radio frequency transmission (GNSS-RF) has the potential to reduce fatal and non-fatal accidents on logging operations through the use of geofences that define safe work areas. Until recently, most geofences have been static boundaries. The aim of this study was to evaluate factors affecting mobile geofence accuracy in order to determine whether virtual safety zones around moving ground workers or equipment are a viable option for improving situational awareness on active timber sales. We evaluated the effects of walking pace, transmission interval, geofence radius, and intersection angle on geofence alert delay using a replicated field experiment. Simulation was then used to validate field results and calculate the proportion of GNSS error bearings resulting in early alerts. The interaction of geofence radius and intersection angle affected safety geofence alert delay in the field experiment. The most inaccurate alerts were negative, representing early warning. The magnitude of this effect was largest at the greatest intersection angles. Simulation analysis supported these field results and also showed that larger GNSS error corresponded to greater variability in alert delay. Increasing intersection angle resulted in a larger proportion of directional GNSS error that triggered incorrect, early warnings. Because the accuracy of geofence alerts varied greatly depending on GNSS error and angle of approach, geofencing for occupational safety is most appropriate for general situational awareness unless real-time correction methods to improve accuracy or higher quality GNSS-RF transponders are used. PMID:28394303
NASA Astrophysics Data System (ADS)
Papaioannou, Athanasios; Mavromichalaki, Helen; Souvatzoglou, George; Paschalis, Pavlos; Sarlanis, Christos; Dimitroulakos, John; Gerontidou, Maria
2013-04-01
High-energy particles released at the Sun during a solar flare or a very energetic coronal mass ejection, result to a significant intensity increase at neutron monitor measurements known as Ground Level Enhancements (GLEs). Due to their space weather impact (i.e. risks and failures at communication and navigation systems, spacecraft electronics and operations, space power systems, manned space missions, and commercial aircraft operations) it is crucial to establish a real-time operational system that would be in place to issue reliable and timely GLE Alerts. Currently, the Cosmic Ray group of the National and Kapodistrian University of Athens is working towards the establishment of a Neutron Monitor Service that will be made available via the Space Weather Portal operated by the European Space Agency (ESA), under the Space Situational Awareness (SSA) Program. To this end, a web interface providing data from multiple Neutron Monitor stations as well as an upgraded GLE Alert will be provided. Both services are now under testing and validation and they will probably enter to an operational phase next year. The core of this Neutron Monitor Service is the GLE Alert software, and therefore, the main goal of this research effort is to upgrade the existing GLE Alert software, to minimize the probability of a false alarm and to enhance the usability of the corresponding results. The ESA Neutron Monitor Service is building upon the infrastructure made available with the implementation of the High-Resolution Neutron Monitor Database (NMDB). In this work the structure of the Neutron Monitor Service for ESA SSA Program and the impact of the novel GLE Alert Service that will be made available to future users via ESA SSA web portal will be presented and further discussed.
Risk management, or just a different risk?
Freer, Y; Lyon, A
2006-09-01
National reporting of adverse incidents has resulted in a number of clinical alerts being issued. Despite a lack of evidence, these alerts are often accompanied by a mandatory requirement to alter practice. There is likely to be clinician resistance to such a method of change management, particularly where evidence of safety is missing. To determine the level of implementation within neonatal units of an alert requiring the change from litmus to pH paper to test nasogastric tube position. A questionnaire sent to all neonatal units in the United Kingdom with more than 12 cots. From the 207 questionnaires sent, there were 165 (80%) responses. Fifty five percent of units were still using litmus. All continued to use supplementary tests not recommended in best practice statements issued at the time of the alert. There was considerable variation in the pH value at which it was considered safe to feed. Nine months after the alert, more than half the units had not changed to pH paper, and supplementary methods of testing were still being used. The wide range of pH values highlights the uncertainty about the "normal" gastric pH in the newborn. The evidence that, in neonatal units, changing to pH paper is safer than the long established use of litmus is lacking. Recommendations for change in practice must be based on good information and not seen just as a "knee jerk" response to adverse incidents.
content of resource. contentinfo contains meta information about the content on the page or the page as a Applications Vocabulary alert A message with important, and usually time-sensitive, information. Also see : true, false, or mixed. columnheader A cell containing header information for a column. combobox A
Piezoelectric Vibrational and Acoustic Alert for a Personal Communication Device
NASA Technical Reports Server (NTRS)
Woodard, Stanley E. (Inventor); Hellbaum, Richard F. (Inventor); Daugherty, Robert H. (Inventor); Scholz, Raymond C. (Inventor); Little, Bruce D. (Inventor); Fox, Robert L. (Inventor); Denhardt, Gerald A. (Inventor); Jang, SeGon (Inventor); Balein, Rizza (Inventor)
2001-01-01
An alert apparatus for a personal communication device includes a mechanically prestressed piezoelectric wafer positioned within the personal communication device and an alternating voltage input line coupled at two points of the wafer where polarity is recognized. The alert apparatus also includes a variable frequency device coupled to the alternating voltage input line, operative to switch the alternating voltage on the alternating voltage input line at least between an alternating voltage having a first frequency and an alternating voltage having a second frequency. The first frequency is preferably sufficiently high so as to cause the wafer to vibrate at a resulting frequency that produces a sound perceptible by a human ear, and the second frequency is preferably sufficiently low so as to cause the wafer to vibrate at a resulting frequency that produces a vibration readily felt by a holder of the personal communication device.
NASA Astrophysics Data System (ADS)
Meier, M.; Cua, G. B.; Wiemer, S.; Fischer, M.
2011-12-01
The Virtual Seismologist (VS) method is a Bayesian approach to regional network-based earthquake early warning (EEW) that uses observed phase arrivals, ground motion amplitudes and selected prior information to estimate earthquake magnitude, location and origin time, and predict the distribution of peak ground motion throughout a region using envelope attenuation relationships. Implementation of the VS algorithm in California is an on-going effort of the Swiss Seismological Service (SED) at ETH Zürich. VS is one of three EEW algorithms - the other two being ElarmS (Allen and Kanamori, 2003) and On-Site (Wu and Kanamori, 2005; Boese et al., 2008) - that form the basis of the California Integrated Seismic Network ShakeAlert system, a prototype end-to-end EEW system that could potentially be implemented in California. The current prototype version of VS in California requires picks at 4 stations to initiate an event declaration. On average, taking into account data latency, variable station distribution, and processing time, this initial estimate is available about 20 seconds after the earthquake origin time, corresponding to a blind zone of about 70 km around the epicenter which would receive no warning, but where it would be the most useful. To increase the available warning time, we want to produce EEW estimates faster (with less than 4 stations). However, working with less than 4 stations with our current approach would increase the number of false alerts, for which there is very little tolerance in a useful EEW system. We explore the use of back-azimuth estimations and the Voronoi-based concept of not-yet-arrived data for reducing false alerts of the earliest VS estimates. The concept of not-yet-arrived data was originally used to provide evolutionary location estimates in EEW (Horiuchi, 2005; Cua and Heaton, 2007; Satriano et al. 2008). However, it can also be applied in discriminating between earthquake and non-earthquake signals. For real earthquakes, the constraints on earthquake location from the not-yet-arrived data and the back-azimuth estimations are consistent with location constraints from the available picks. For non-earthquake signals, these different location constraints are in most cases inconsistent. We use archived event data from the Northern and Southern California Seismic Networks as well as archived continuous waveform data from where the current VS codes erroneously declared events to quantify how using a combination of pick-based and not-yet-arrived data constraints can reduce VS false alert rates while providing faster warning information. The consistency of the pick-based and not-yet-arrived data constraints are mapped into the VS likelihood parameter, which reflects the degree of believe that the signals come from a real earthquake. This approach contributes towards improving the robustness of the Virtual Seismologist Multiple Threshold Event Detection (VS-MTED), which allows for single-station event declarations, when signal amplitudes are large enough.
ERIC Educational Resources Information Center
Kourea, Lefki; Lo, Ya-yu; Owens, Tosha L.
2016-01-01
Despite the positive effects of school-wide positive behavior support (SWPBS) on school discipline, the overrepresentation of Black students in discipline data in SWPBS schools has alerted researchers and educators to initiate discussion about the need to blend culturally responsive pedagogy and the SWPBS approach. This qualitative research study…
Osteoarthritis of the Foot and Ankle
... in or near the joint Difficulty walking or bending the joint Some patients with osteoarthritis also develop ... ps.position.alert.message}} Getting your location, one moment... Please enter a 5-digit zip code. Please ...
Alsolamy, Sami; Al Salamah, Majid; Al Thagafi, Majed; Al-Dorzi, Hasan M; Marini, Abdellatif M; Aljerian, Nawfal; Al-Enezi, Farhan; Al-Hunaidi, Fatimah; Mahmoud, Ahmed M; Alamry, Ahmed; Arabi, Yaseen M
2014-12-05
Early recognition of severe sepsis and septic shock is challenging. The aim of this study was to determine the diagnostic accuracy of an electronic alert system in detecting severe sepsis or septic shock among emergency department (ED) patients. An electronic sepsis alert system was developed as a part of a quality-improvement project for severe sepsis and septic shock. The system screened all adult ED patients for a combination of systemic inflammatory response syndrome and organ dysfunction criteria (hypotension, hypoxemia or lactic acidosis). This study included all patients older than 14 years who presented to the ED of a tertiary care academic medical center from Oct. 1, 2012 to Jan. 31, 2013. As a comparator, emergency medicine physicians or the critical care physician identified the patients with severe sepsis or septic shock. In the ED, vital signs were manually entered into the hospital electronic heath record every hour in the critical care area and every two hours in other areas. We also calculated the time from the alert to the intensive care unit (ICU) referral. Of the 49,838 patients who presented to the ED, 222 (0.4%) were identified to have severe sepsis or septic shock. The electronic sepsis alert had a sensitivity of 93.18% (95% CI, 88.78% - 96.00%), specificity of 98.44 (95% CI, 98.33% - 98.55%), positive predictive value of 20.98% (95% CI, 18.50% - 23.70%) and negative predictive value of 99.97% (95% CI, 99.95% - 99.98%) for severe sepsis and septic shock. The alert preceded ICU referral by a median of 4.02 hours (Q1 - Q3: 1.25-8.55). Our study shows that electronic sepsis alert tool has high sensitivity and specificity in recognizing severe sepsis and septic shock, which may improve early recognition and management.
Almuhayawi, Mohammed; Altun, Osman; Abdulmajeed, Adam Dilshad; Ullberg, Måns; Özenci, Volkan
2015-01-01
Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS. PMID:26554930
Almuhayawi, Mohammed; Altun, Osman; Abdulmajeed, Adam Dilshad; Ullberg, Måns; Özenci, Volkan
2015-01-01
Detection and identification of anaerobic bacteria in blood cultures (BC) is a well-recognized challenge in clinical microbiology. We studied 100 clinical anaerobic BC isolates to evaluate the performance of BacT/ALERT-FN, -FN Plus (BioMérieux), BACTEC-Plus and -Lytic (Becton Dickinson BioSciences) BC bottles in detection and time to detection (TTD) of anaerobic bacteria. BACTEC Lytic had higher detection rate (94/100, 94%) than BacT/ALERT FN Plus (80/100, 80%) (p<0.01) in the studied material. There was no significant difference in detection of anaerobic bacteria among the remaining bottle types. The 67 anaerobic bacteria that signalled positive in all four bottle types were analyzed to compare the time to detection (TTD) and isolates were directly identified by MALDI-TOF MS. There was a significant difference in TTD among the four bottle types (p<0.0001). The shortest median TTD was 18 h in BACTEC Lytic followed by BacT/ALERT FN (23.5 h), BACTEC Plus (27 h) and finally BacT/ALERT FN Plus (38 h) bottles. In contrast, MALDI-TOF MS performed similarly in all bottle types with accurate identification in 51/67 (76%) BacT/ALERT FN, 51/67 (76%) BacT/ALERT FN Plus, 53/67 (79%) BACTEC Plus and 50/67 (75%) BACTEC Lytic bottles. In conclusion, BACTEC Lytic bottles have significantly better detection rates and shorter TTD compared to the three other bottle types. The anaerobic BC bottles are equally suitable for direct MALDI-TOF MS for rapid and reliable identification of common anaerobic bacteria. Further clinical studies are warranted to investigate the performance of anaerobic BC bottles in detection of anaerobic bacteria and identification by direct MALDI-TOF MS.
Sharing Concerns: Interpersonal Worry Regulation in Romantic Couples
2016-01-01
Two dyadic studies investigated interpersonal worry regulation in heterosexual relationships. In Study 1, we video-recorded 40 romantic couples discussing shared concerns. Male partners’ worry positively predicted female partners’ interpersonal calming attempts, and negatively predicted female partners’ interpersonal alerting attempts (i.e., attempts to make their partners appreciate the seriousness of concerns). Video-cued recall data also indicated that changes in partner A’s worry over time positively predicted partner B’s motivation to reduce partner A’s worry, and that this effect was stronger when B was the female partner. Study 2 was a dyadic survey of 100 couples. Individual differences in partner A’s negative affect were positive predictors of partner B’s interpersonal calming, and individual differences in partner A’s expressive suppression were negative predictors of partner B’s interpersonal calming. Further, individual differences in male partners’ expressivity were significant positive predictors of female partners’ interpersonal calming, and individual differences in male partners’ reappraisal were significant positive predictors of female partners’ interpersonal alerting. These findings suggest that interpersonal worry regulation relates to partners’ expression and intrapersonal regulation of worry, but not equally for men and women. PMID:26882336
Twitter Seismology: Earthquake Monitoring and Response in a Social World
NASA Astrophysics Data System (ADS)
Bowden, D. C.; Earle, P. S.; Guy, M.; Smoczyk, G.
2011-12-01
The U.S. Geological Survey (USGS) is investigating how the social networking site Twitter, a popular service for sending and receiving short, public, text messages, can augment USGS earthquake response products and the delivery of hazard information. The potential uses of Twitter for earthquake response include broadcasting earthquake alerts, rapidly detecting widely felt events, qualitatively assessing earthquake damage effects, communicating with the public, and participating in post-event collaboration. Several seismic networks and agencies are currently distributing Twitter earthquake alerts including the European-Mediterranean Seismological Centre (@LastQuake), Natural Resources Canada (@CANADAquakes), and the Indonesian meteorological agency (@infogempabmg); the USGS will soon distribute alerts via the @USGSted and @USGSbigquakes Twitter accounts. Beyond broadcasting alerts, the USGS is investigating how to use tweets that originate near the epicenter to detect and characterize shaking events. This is possible because people begin tweeting immediately after feeling an earthquake, and their short narratives and exclamations are available for analysis within 10's of seconds of the origin time. Using five months of tweets that contain the word "earthquake" and its equivalent in other languages, we generate a tweet-frequency time series. The time series clearly shows large peaks correlated with the origin times of widely felt events. To identify possible earthquakes, we use a simple Short-Term-Average / Long-Term-Average algorithm similar to that commonly used to detect seismic phases. As with most auto-detection algorithms, the parameters can be tuned to catch more or less events at the cost of more or less false triggers. When tuned to a moderate sensitivity, the detector found 48 globally-distributed, confirmed seismic events with only 2 false triggers. A space-shuttle landing and "The Great California ShakeOut" caused the false triggers. This number of detections is very small compared to the 5,175 earthquakes in the USGS PDE global earthquake catalog for the same five month time period, and no accurate location or magnitude can be assigned based on Tweet data alone. However, Twitter earthquake detections are not without merit. The detections are generally caused by widely felt events that are of more immediate interest than those with no human impact. The detections are also fast; about 80% occurred within 2 minutes of the origin time. This is considerably faster than seismographic detections in poorly instrumented regions of the world. The tweets triggering the detections also provided (very) short first-impression narratives from people who experienced the shaking. The USGS will continue investigating how to use Twitter and other forms of social media to augment is current suite of seismographically derived products.
A Comparison of Blue Light and Caffeine Effects on Cognitive Function and Alertness in Humans
Beaven, C. Martyn; Ekström, Johan
2013-01-01
The alerting effects of both caffeine and short wavelength (blue) light have been consistently reported. The ability of blue light to enhance alertness and cognitive function via non-image forming neuropathways have been suggested as a non-pharmacological countermeasure for drowsiness across a range of occupational settings. Here we compare and contrast the alerting and psychomotor effects of 240 mg of caffeine and a 1-h dose of ~40 lx blue light in a non-athletic population. Twenty-one healthy subjects performed a computer-based psychomotor vigilance test before and after each of four randomly assigned trial conditions performed on different days: white light/placebo; white light/240 mg caffeine; blue light/placebo; blue light/240 mg caffeine. The Karolinska Sleepiness Scale was used to assess subjective measures of alertness. Both the caffeine only and blue light only conditions enhanced accuracy in a visual reaction test requiring a decision and an additive effect was observed with respect to the fastest reaction times. However, in a test of executive function, where a distraction was included, caffeine exerted a negative effect on accuracy. Furthermore, the blue light only condition consistently outperformed caffeine when both congruent and incongruent distractions were presented. The visual reactions in the absence of a decision or distraction were also enhanced in the blue light only condition and this effect was most prominent in the blue-eyed participants. Overall, blue light and caffeine demonstrated distinct effects on aspects of psychomotor function and have the potential to positively influence a range of settings where cognitive function and alertness are important. Specifically, despite the widespread use of caffeine in competitive sporting environments, the possible impact of blue light has received no research attention. PMID:24282477
NASA Astrophysics Data System (ADS)
Vernaleken, Christoph; Mihalic, Lamir; Güttler, Mathias; Klingauf, Uwe
2006-05-01
Increasing traffic density on the aerodrome surface due to the continuous worldwide growth in the number of flight operations does not only cause capacity and efficiency problems, but also increases the risk of serious incidents and accidents on the airport movement area. Of these, Runway Incursions are the by far most safety-critical. In fact, the worst-ever accident in civil aviation, the collision of two Boeing B747s on Tenerife in 1977 with 583 fatalities, was caused by a Runway Incursion. Therefore, various Runway Safety programs have recently been initiated around the globe, often focusing on ground-based measures such as improved surveillance. However, as a lack of flight crew situational awareness is a key causal factor in many Runway Incursion incidents and accidents, there is a strong need for an onboard solution, which should be capable of interacting cooperatively with ground-based ATM systems, such as A-SMGCS where available. This paper defines the concept of preventive and reactive Runway Incursion avoidance and describes a Surface Movement Awareness & Alerting System (SMAAS) designed to alert the flight crew if they are at risk of infringing a runway. Both the SVS flight deck displays and the corresponding alerting algorithms utilize an ED 99A/RTCA DO-272A compliant aerodrome database, as well as airport operational, traffic and clearance data received via ADS-B or other data links, respectively. The displays provide the crew with enhanced positional, operational, clearance and traffic awareness, and they are used to visualize alerts. A future enhancement of the system will provide intelligent alerting for conflicts caused by surrounding traffic.
Airborne Data Link Study Report
DOT National Transportation Integrated Search
1996-01-01
This report represents evaluations of Data Link products and services in a simulated aviation opearation. The study addresses key issues related to alerting schemes for Data Link messages, positioning of Data Link displays, and mode of presentation o...
McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras
2016-01-01
Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time—the time elapsed from when an interruptive alert is generated to when it is dismissed—could be calculated by using historical alert data from log files. Drug–drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1–4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < .001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < .001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. PMID:26499101
Lumber defect detection abilities of furniture rough mill employees
Henry A. Huber; Charles W. McMillin; John P. McKinney
1985-01-01
To cut parts from boards, rough mill employees must be able to see defects, calculate the proper location of cuts, manually position the board, and remain alert. The objective of this study was to evaluate how well rough mill employees perform the task of recognizing, locating, and identifying surface defects independent of the calculation and positioning process....
Metric Education; A Position Paper for Vocational, Technical and Adult Education.
ERIC Educational Resources Information Center
Cooper, Gloria S.; And Others
Part of an Office of Education three-year project on metric education, the position paper is intended to alert and prepare teachers, curriculum developers, and administrators in vocational, technical, and adult education to the change over to the metric system. The five chapters cover issues in metric education, what the metric system is all…
Risk management, or just a different risk?
Freer, Y; Lyon, A
2006-01-01
Background National reporting of adverse incidents has resulted in a number of clinical alerts being issued. Despite a lack of evidence, these alerts are often accompanied by a mandatory requirement to alter practice. There is likely to be clinician resistance to such a method of change management, particularly where evidence of safety is missing. Aim To determine the level of implementation within neonatal units of an alert requiring the change from litmus to pH paper to test nasogastric tube position. Method A questionnaire sent to all neonatal units in the United Kingdom with more than 12 cots. Results From the 207 questionnaires sent, there were 165 (80%) responses. Fifty five percent of units were still using litmus. All continued to use supplementary tests not recommended in best practice statements issued at the time of the alert. There was considerable variation in the pH value at which it was considered safe to feed. Conclusions Nine months after the alert, more than half the units had not changed to pH paper, and supplementary methods of testing were still being used. The wide range of pH values highlights the uncertainty about the “normal” gastric pH in the newborn. The evidence that, in neonatal units, changing to pH paper is safer than the long established use of litmus is lacking. Recommendations for change in practice must be based on good information and not seen just as a “knee jerk” response to adverse incidents. PMID:16464936
Zorina, Olesya I; Haueis, Patrick; Semmler, Alexander; Marti, Isabelle; Gonzenbach, Roman R; Guzek, Markus; Kullak-Ublick, Gerd A; Weller, Michael; Russmann, Stefan
2012-08-01
The comparative evaluation of clinical decision support software (CDSS) programs regarding their sensitivity and positive predictive value for the identification of clinically relevant drug interactions. In this research, we used a cross-sectional study that identified potential drug interactions using the CDSS MediQ and the ID PHARMA CHECK in 484 neurological inpatients. Interactions were reclassified according to the Zurich Interaction System, a multidimensional classification that incorporates the Operational Classification of Drug Interactions. In 484 patients with 2812 prescriptions, MediQ and ID PHARMA CHECK generated a total of 1759 and 1082 alerts, respectively. MediQ identified 658 unique potentially interacting combinations, 8 classified as "high danger," 164 as "average danger," and 486 as "low danger." ID PHARMA CHECK detected 336 combinations assigned to one or several of 12 risk and management categories. Altogether, both CDSS issued alerts relating to 808 unique potentially interacting combinations. According to the Zurich Interaction System, 6 of these were contraindicated, 25 were provisionally contraindicated, 190 carried a conditional risk, and 587 had a minimal risk of adverse events. The positive predictive value for alerts having at least a conditional risk was 0.24 for MediQ and 0.48 for ID PHARMA CHECK. CDSS showed major differences in the identification and grading of interactions, and many interactions were only identified by one of the two CDSS. For both programs, only a small proportion of all identified interactions appeared clinically relevant, and the selected display of alerts that imply management changes is a key issue in the further development and local setup of such programs. Copyright © 2012 John Wiley & Sons, Ltd.
Mirus, Benjamin B.; Becker, Rachel E.; Baum, Rex L.; Smith, Joel B.
2018-01-01
Early warning for rainfall-induced shallow landsliding can help reduce fatalities and economic losses. Although these commonly occurring landslides are typically triggered by subsurface hydrological processes, most early warning criteria rely exclusively on empirical rainfall thresholds and other indirect proxies for subsurface wetness. We explore the utility of explicitly accounting for antecedent wetness by integrating real-time subsurface hydrologic measurements into landslide early warning criteria. Our efforts build on previous progress with rainfall thresholds, monitoring, and numerical modeling along the landslide-prone railway corridor between Everett and Seattle, Washington, USA. We propose a modification to a previously established recent versus antecedent (RA) cumulative rainfall thresholds by replacing the antecedent 15-day rainfall component with an average saturation observed over the same timeframe. We calculate this antecedent saturation with real-time telemetered measurements from five volumetric water content probes installed in the shallow subsurface within a steep vegetated hillslope. Our hybrid rainfall versus saturation (RS) threshold still relies on the same recent 3-day rainfall component as the existing RA thresholds, to facilitate ready integration with quantitative precipitation forecasts. During the 2015–2017 monitoring period, this RS hybrid approach has an increase of true positives and a decrease of false positives and false negatives relative to the previous RA rainfall-only thresholds. We also demonstrate that alternative hybrid threshold formats could be even more accurate, which suggests that further development and testing during future landslide seasons is needed. The positive results confirm that accounting for antecedent wetness conditions with direct subsurface hydrologic measurements can improve thresholds for alert systems and early warning of rainfall-induced shallow landsliding.
Wright, Adam; Aaron, Skye; Seger, Diane L; Samal, Lipika; Schiff, Gordon D; Bates, David W
2018-05-15
Drug-drug interaction (DDI) alerts in electronic health records (EHRs) can help prevent adverse drug events, but such alerts are frequently overridden, raising concerns about their clinical usefulness and contribution to alert fatigue. To study the effect of conversion to a commercial EHR on DDI alert and acceptance rates. Two before-and-after studies. 3277 clinicians who received a DDI alert in the outpatient setting. Introduction of a new, commercial EHR and subsequent adjustment of DDI alerting criteria. Alert burden and proportion of alerts accepted. Overall interruptive DDI alert burden increased by a factor of 6 from the legacy EHR to the commercial EHR. The acceptance rate for the most severe alerts fell from 100 to 8.4%, and from 29.3 to 7.5% for medium severity alerts (P < 0.001). After disabling the least severe alerts, total DDI alert burden fell by 50.5%, and acceptance of Tier 1 alerts rose from 9.1 to 12.7% (P < 0.01). Changing from a highly tailored DDI alerting system to a more general one as part of an EHR conversion decreased acceptance of DDI alerts and increased alert burden on users. The decrease in acceptance rates cannot be fully explained by differences in the clinical knowledge base, nor can it be fully explained by alert fatigue associated with increased alert burden. Instead, workflow factors probably predominate, including timing of alerts in the prescribing process, lack of differentiation of more and less severe alerts, and features of how users interact with alerts.
INITIATE: An Intelligent Adaptive Alert Environment.
Jafarpour, Borna; Abidi, Samina Raza; Ahmad, Ahmad Marwan; Abidi, Syed Sibte Raza
2015-01-01
Exposure to a large volume of alerts generated by medical Alert Generating Systems (AGS) such as drug-drug interaction softwares or clinical decision support systems over-whelms users and causes alert fatigue in them. Some of alert fatigue effects are ignoring crucial alerts and longer response times. A common approach to avoid alert fatigue is to devise mechanisms in AGS to stop them from generating alerts that are deemed irrelevant. In this paper, we present a novel framework called INITIATE: an INtellIgent adapTIve AlerT Environment to avoid alert fatigue by managing alerts generated by one or more AGS. We have identified and categories the lifecycle of different alerts and have developed alert management logic as per the alerts' lifecycle. Our framework incorporates an ontology that represents the alert management strategy and an alert management engine that executes this strategy. Our alert management framework offers the following features: (1) Adaptability based on users' feedback; (2) Personalization and aggregation of messages; and (3) Connection to Electronic Medical Records by implementing a HL7 Clinical Document Architecture parser.
That Pain in Your Back Could be Linked to Your Feet
... hurts, so you change your gait to avoid bending the joint when you walk. Changing your gait ... ps.position.alert.message}} Getting your location, one moment... Please enter a 5-digit zip code. Please ...
Wearable vital parameters monitoring system
NASA Astrophysics Data System (ADS)
Caramaliu, Radu Vadim; Vasile, Alexandru; Bacis, Irina
2015-02-01
The system we propose monitors body temperature, heart rate and beside this, it tracks if the person who wears it suffers a faint. It uses a digital temperature sensor, a pulse sensor and a gravitational acceleration sensor to monitor the eventual faint or small heights free falls. The system continuously tracks the GPS position when available and stores the last valid data. So, when measuring abnormal vital parameters the module will send an SMS, using the GSM cellular network , with the person's social security number, the last valid GPS position for that person, the heart rate, the body temperature and, where applicable, a valid fall alert or non-valid fall alert. Even though such systems exist, they contain only faint detection or heart rate detection. Usually there is a strong correlation between low/high heart rate and an eventual faint. Combining both features into one system results in a more reliable detection device.
Effectiveness of an expert system for astronaut assistance on a sleep experiment.
Callini, G; Essig, S M; Heher, D M; Young, L R
2000-10-01
Principal Investigator-in-a-Box ([PI]) is an expert system designed to train and assist astronauts with the performance of an experiment outside their field of expertise, particularly when contact with the Principal Investigators on the ground is limited or impossible. In the current case, [PI] was designed to assist with the calibration and troubleshooting procedures of the Neurolab Sleep and Respiration Experiment. [PI] displays physiological signals in real time during the pre-sleep instrumentation period, alerts the astronauts when a poor signal quality is detected, and displays steps to improve quality. Two studies are presented in this paper. In the first study 12 subjects monitored a set of prerecorded physiological signals and attempted to identify any signal artifacts appearing on the computer screen. Every subject performed the experiment twice, once with the assistance of [PI] and once without. The second part of this study focuses on the postflight analysis of the data gathered from the Neurolab Mission. After replaying the physiological signals on the ground, the frequency of correct [PI] alerts and false alarms (i.e., incorrect diagnoses by the expert system) was determined in order to assess the robustness and accuracy of the rules. Results of the ground study indicated a beneficial effect of [PI] and training in reducing anomaly detection time and the number of undetected anomalies. For the in-flight performance, excluding the saturated signals, the expert system had an 84% detection accuracy, and the questionnaires filled out by the astronauts showed positive crew reactions to the expert system.
McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras; Hoffman, James M
2016-04-01
Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time-the time elapsed from when an interruptive alert is generated to when it is dismissed-could be calculated by using historical alert data from log files. Drug-drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1-4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < 001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < 001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Electronic search and rescue aids
NASA Technical Reports Server (NTRS)
Trudell, B. J.
1980-01-01
There are two elements to the basic electronic search and rescue problem: a means for immediately alerting potential rescuers and an effective method to guide the rescue forces to the scene of the emergency. An Emergency Locator Transmitter (ELT) used by aircraft or an Emergency Position Indicating Radio Beacon (EPIRB) used by maritime vessels has the capability of providing for both an immediate alert and a homing signal to assist rescue forces in locating the site of the distress. This paper describes the development of ELT/EPIRB systems. Emphasis is placed on the SARSAT project, the COSPAS/SARSAT project, and an experimental 406 MHz ELT/EPIRB system.
Marko, Kathryn I; Krapf, Jill M; Meltzer, Andrew C; Oh, Julia; Ganju, Nihar; Martinez, Anjali G; Sheth, Sheetal G; Gaba, Nancy D
2016-11-18
Excessive weight gain and elevated blood pressure are significant risk factors for adverse pregnancy outcomes such as gestational diabetes, premature birth, and preeclampsia. More effective strategies to facilitate adherence to gestational weight gain goals and monitor blood pressure may have a positive health benefit for pregnant women and their babies. The impact of utilizing a remote patient monitoring system to monitor blood pressure and weight gain as a component of prenatal care has not been previously assessed. The objective of this study is to determine the feasibility of monitoring patients remotely in prenatal care using a mobile phone app and connected digital devices. In this prospective observational study, 8 women with low risk pregnancy in the first trimester were recruited at an urban academic medical center. Participants received a mobile phone app with a connected digital weight scale and blood pressure cuff for at-home data collection for the duration of pregnancy. At-home data was assessed for abnormal values of blood pressure or weight to generate clinical alerts to the patient and provider. As measures of the feasibility of the system, participants were studied for engagement with the app, accuracy of remote data, efficacy of alert system, and patient satisfaction. Patient engagement with the mobile app averaged 5.5 times per week over the 6-month study period. Weight data collection and blood pressure data collection averaged 1.5 times and 1.1 times per week, respectively. At-home measurements of weight and blood pressure were highly accurate compared to in-office measurements. Automatic clinical alerts identified two episodes of abnormal weight gain with no false triggers. Patients demonstrated high satisfaction with the system. In this pilot study, we demonstrated that a system using a mobile phone app coupled to remote monitoring devices is feasible for prenatal care. ©Kathryn I Marko, Jill M Krapf, Andrew C Meltzer, Julia Oh, Nihar Ganju, Anjali G Martinez, Sheetal G Sheth, Nancy D Gaba. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 18.11.2016.
Applying Binary Forecasting Approaches to Induced Seismicity in the Western Canada Sedimentary Basin
NASA Astrophysics Data System (ADS)
Kahue, R.; Shcherbakov, R.
2016-12-01
The Western Canada Sedimentary Basin has been chosen as a focus due to an increase in the recent observed seismicity there which is most likely linked to anthropogenic activities related to unconventional oil and gas exploration. Seismicity caused by these types of activities is called induced seismicity. The occurrence of moderate to larger induced earthquakes in areas where critical infrastructure is present can be potentially problematic. Here we use a binary forecast method to analyze past seismicity and well production data in order to quantify future areas of increased seismicity. This method splits the given region into spatial cells. The binary forecast method used here has been suggested in the past to retroactively forecast large earthquakes occurring globally in areas called alarm cells. An alarm cell, or alert zone, is a bin in which there is a higher likelihood for earthquakes to occur based on previous data. The first method utilizes the cumulative Benioff strain, based on earthquakes that had occurred in each bin above a given magnitude over a time interval called the training period. The second method utilizes the cumulative well production data within each bin. Earthquakes that occurred within an alert zone in the retrospective forecast period contribute to the hit rate, while alert zones that did not have an earthquake occur within them in the forecast period contribute to the false alarm rate. In the resulting analysis the hit rate and false alarm rate are determined after optimizing and modifying the initial parameters using the receiver operating characteristic diagram. It is found that when modifying the cell size and threshold magnitude parameters within various training periods, hit and false alarm rates are obtained for specific regions in Western Canada using both recent seismicity and cumulative well production data. Certain areas are thus shown to be more prone to potential larger earthquakes based on both datasets. This has implications for the potential link between oil and gas production and induced seismicity observed in the Western Canada Sedimentary Basin.
2006-11-01
positive reinforcement as a motivating stimulus (small pieces of marshmallow ) has been used to asses the HEC [Philippens et al. 2000]. The marmoset...apparatus using positive reinforcement as a motivating stimulus for the animals (small pieces of marshmallow ) has been used to asses the Hand-eye
First described case of prosthetic joint infection with Clostridium disporicum.
McBride, Joseph A; Sterkel, Alana K; Rehrauer, William M; Smith, Jeannina A
2017-12-01
An orthopedic hardware infection with Clostridium disporicum is described. C. disporicum is a gram positive anaerobic bacillus which can contain two subterminal spores. C. disporicum had not previously been reported in musculoskeletal infections. Gram stains demonstrating gram positive bacilli with two subterminal spores should alert practitioners to the possibility of C. disporicum infection. Published by Elsevier Ltd.
Fadda, Antonio; Frongia, Giorgio; Sanna, Antonietta; Melillo, Rita
2015-01-01
Listeria (L.) monocytogenes is frequently isolated from food production environment and often persists in dairy plants despite vigorous sanitation regimes. In recent years several alert notifications were sent to Rapid Alert System for Food Products system as a consequence of Listeria monocytogenes contamination of ricotta cheese. After the alert of 2012, competent authority (Local Health Unit of Sassari Province) organised an environmental monitoring plan with the partnership of the Institute for Experimental Veterinary Medicine of Sardinia to verify analysis of dairy plants own-check according to Regulation (EC) N° 2073/05 and further modifications. In 2014 n. 665 processing areas samples of n. 50 dairy plants of Sassari Province were examined. UNI EN ISO 11290-1:2005 for detection of L. monocytogenes was used. Non-compliance in n. 5 diary plants are observed (n. 8 positive samples). Post-non-compliance environmental sanitisation was efficient and own-check plans included appropriate corrective actions. PMID:27800407
Positive airway pressure treatment
... it. After using PAP regularly, you may notice: Better concentration and memory Feeling more alert and less sleepy during the day Improved sleep for your bed partner Being more productive at ... and a better mood Normal sleep patterns Lower blood pressure (in ...
Pelat, Camille; Bonmarin, Isabelle; Ruello, Marc; Fouillet, Anne; Caserio-Schönemann, Céline; Levy-Bruhl, Daniel; Le Strat, Yann
2017-08-10
The 2014/15 influenza epidemic caused a work overload for healthcare facilities in France. The French national public health agency announced the start of the epidemic - based on indicators aggregated at the national level - too late for many hospitals to prepare. It was therefore decided to improve the influenza alert procedure through (i) the introduction of a pre-epidemic alert level to better anticipate future outbreaks, (ii) the regionalisation of surveillance so that healthcare structures can be informed of the arrival of epidemics in their region, (iii) the standardised use of data sources and statistical methods across regions. A web application was developed to deliver statistical results of three outbreak detection methods applied to three surveillance data sources: emergency departments, emergency general practitioners and sentinel general practitioners. This application was used throughout the 2015/16 influenza season by the epidemiologists of the headquarters and regional units of the French national public health agency. It allowed them to signal the first influenza epidemic alert in week 2016-W03, in Brittany, with 11 other regions in pre-epidemic alert. This application received positive feedback from users and was pivotal for coordinating surveillance across the agency's regional units. This article is copyright of The Authors, 2017.
Effect of Traffic Position Accuracy for Conducting Safe Airport Surface Operations
NASA Technical Reports Server (NTRS)
Jones, Denise R.; Prinzel, Lawrence J., III; Bailey, Randall E.; Arthur, Jarvis J., III; Barnes, James R.
2014-01-01
The Next Generation Air Transportation System (NextGen) concept proposes many revolutionary operational concepts and technologies, such as display of traffic information and movements, airport moving maps (AMM), and proactive alerts of runway incursions and surface traffic conflicts, to deliver an overall increase in system capacity and safety. A piloted simulation study was conducted at the National Aeronautics and Space Administration (NASA) Langley Research Center to evaluate the ability to conduct safe and efficient airport surface operations while utilizing an AMM displaying traffic of various position accuracies as well as the effect of traffic position accuracy on airport conflict detection and resolution (CD&R) capability. Nominal scenarios and off-nominal conflict scenarios were conducted using 12 airline crews operating in a simulated Memphis International Airport terminal environment. The data suggest that all traffic should be shown on the airport moving map, whether qualified or unqualified, and conflict detection and resolution technologies provide significant safety benefits. Despite the presence of traffic information on the map, collisions or near collisions still occurred; when indications or alerts were generated in these same scenarios, the incidences were averted.
Weinbach, Noam; Perry, Amit; Sher, Helene; Lock, James D; Henik, Avishai
2017-08-01
Weak central coherence (WCC) refers to a bias towards processing details (local processing) at the expense of paying attention to the bigger picture (global processing). Multiple studies reported WCC in adults with anorexia nervosa (AN). Evidence for WCC in adolescents with AN has been inconsistent. The current study characterizes WCC in weight-restored adolescents with AN (WR-AN) using a direct measure of WCC, and examines whether WCC can be remediated by increasing alertness level-a manipulation that was found useful in enhancing global processing in healthy individuals and clinical populations. 40 adolescents (18 WR-AN and 22 healthy adolescents) performed a global/local processing task (Navon task). Auditory alerting cues that elevate alertness level were integrated into the task. Both groups processed global information faster than local information. However, compared with controls, adolescents with WR-AN were better at ignoring an irrelevant bigger picture while attending to details (smaller global interference) and had greater difficulty ignoring irrelevant details while attending to the bigger picture (larger local interference). These differences were attenuated when adolescents with WR-AN were under a state of high alertness. Additionally, the local interference effect was positively correlated with three independent self-report questionnaires assessing eating disorders symptomatology. This study suggests that abnormal interference by irrelevant global and local information is a central characteristic of WCC in adolescents with WR-AN that cannot be accounted for by enduring illness or malnourishment. Additionally, this study demonstrates that WCC can be temporarily remediated by encouraging a state of high alertness. © 2017 Wiley Periodicals, Inc.
[Circadian rhythm : Influence on Epworth Sleepiness Scale score].
Herzog, M; Bedorf, A; Rohrmeier, C; Kühnel, T; Herzog, B; Bremert, T; Plontke, S; Plößl, S
2017-02-01
The Epworth Sleepiness Scale (ESS) is frequently used to determine daytime sleepiness in patients with sleep-disordered breathing. It is still unclear whether different levels of alertness induced by the circadian rhythm influence ESS score. The aim of this study is to investigate the influence of circadian rhythm-dependent alertness on ESS performance. In a monocentric prospective noninterventional observation study, 97 patients with suspected sleep-disordered breathing were investigated with respect to daytime sleepiness in temporal relationship to polysomnographic examination and treatment. The Karolinska Sleepiness Scale (KSS) and the Stanford Sleepiness Scale (SSS) served as references for the detection of present sleepiness at three different measurement times (morning, noon, evening), prior to and following a diagnostic polysomnography night as well as after a continuous positive airway pressure (CPAP) titration night (9 measurements in total). The KSS, SSS, and ESS were performed at these times in a randomized order. The KSS and SSS scores revealed a circadian rhythm-dependent curve with increased sleepiness at noon and in the evening. Following a diagnostic polysomnography night, the scores were increased compared to the measurements prior to the night. After the CPAP titration night, sleepiness in the morning was reduced. KSS and SSS reflect the changes in alertness induced by the circadian rhythm. The ESS score war neither altered by the intra-daily nor by the inter-daily changes in the level of alertness. According to the present data, the ESS serves as a reliable instrument to detect the level of daytime sleepiness independently of the circadian rhythm-dependent level of alertness.
Using principal component analysis for selecting network behavioral anomaly metrics
NASA Astrophysics Data System (ADS)
Gregorio-de Souza, Ian; Berk, Vincent; Barsamian, Alex
2010-04-01
This work addresses new approaches to behavioral analysis of networks and hosts for the purposes of security monitoring and anomaly detection. Most commonly used approaches simply implement anomaly detectors for one, or a few, simple metrics and those metrics can exhibit unacceptable false alarm rates. For instance, the anomaly score of network communication is defined as the reciprocal of the likelihood that a given host uses a particular protocol (or destination);this definition may result in an unrealistically high threshold for alerting to avoid being flooded by false positives. We demonstrate that selecting and adapting the metrics and thresholds, on a host-by-host or protocol-by-protocol basis can be done by established multivariate analyses such as PCA. We will show how to determine one or more metrics, for each network host, that records the highest available amount of information regarding the baseline behavior, and shows relevant deviances reliably. We describe the methodology used to pick from a large selection of available metrics, and illustrate a method for comparing the resulting classifiers. Using our approach we are able to reduce the resources required to properly identify misbehaving hosts, protocols, or networks, by dedicating system resources to only those metrics that actually matter in detecting network deviations.
Serrano, Jorge; Moros, Javier; Sánchez, Carlos; Macías, Jorge; Laserna, J Javier
2014-01-02
The large similarity existing in the spectral emissions collected from organic compounds by laser-induced breakdown spectroscopy (LIBS) is a limiting factor for the use of this technology in the real world. Specifically, among the most ambitious challenges of today's LIBS involves the recognition of an organic residue when neglected on the surface of an object of identical nature. Under these circumstances, the development of an efficient algorithm to disclose the minute differences within this highly complex spectral information is crucial for a realistic application of LIBS in countering explosive threats. An approach cemented on scatter plots of characteristic emission features has been developed to identify organic explosives when located on polymeric surfaces (teflon, nylon and polyethylene). By using selected spectral variables, the approach allows to design a concise classifier for alerting when one of four explosives (DNT, TNT, RDX and PETN) is present on the surface of the polymer. Ordinary products (butter, fuel oil, hand cream, olive oil and motor oil) cause no confusion in the decisions taken by the classifier. With rates of false negatives and false positives below 5%, results demonstrate that the classification algorithm enables to label residues according to their harmful nature in the most demanding scenario for a LIBS sensor. Copyright © 2013 Elsevier B.V. All rights reserved.
Advanced alerting features: displaying new relevant data and retracting alerts.
Kuperman, G. J.; Hiltz, F. L.; Teich, J. M.
1997-01-01
We added two advanced features to our automated alerting system. The first feature identifies and displays, at the time an alert is reviewed, relevant data filed between the login time of a specimen leading to an alerting result and the time the alert is reviewed. Relevant data is defined as data of the same kind as generated the alert. The other feature retracts alerts when the alerting value is edited and no longer satisfies the alerting criteria. We evaluated the two features for a 14-week period (new relevant data) and a 6-week period (retraction). Of a total of 1104 alerts in the 14-week evaluation, 286 (25.9%) had new relevant data displayed at alert review time. Of the 286, 75.2% were due to additions of comments to the original piece of alerting data; 24.1% were due to new or pending laboratory results of the same type that generated the alert. Two alerts (out of 490) were retracted in a 6 week period. We conclude that in our system, new clinically relevant data is often added between the time of specimen login and the time that an alerting result from that specimen is reviewed. Retractions occur rarely but are important to detect and communicate. PMID:9357625
Evaluating 6 ricin field detection assays.
Slotved, Hans-Christian; Sparding, Nadja; Tanassi, Julia Tanas; Steenhard, Nina R; Heegaard, Niels H H
2014-01-01
This study presents data showing the performance of 6 commercial detection assays against ricin around concentrations specified as detection limits by the producers. A 2-fold dilution series of 20 ng/ml ricin was prepared and used for testing the lateral-flow kits: BADD, Pro Strips™, ENVI, RAID DX, Ricin BioThreat Alert, and IMASS™ device. Three of the 6 tested field assays (IMASS™ device, ENVI assay, and the BioThreat Alert assay) were able to detect ricin, although differences in the measured detection limits compared to the official detection limits and false-negative results were observed. We were not able to get the BADD, Pro Strips™, and RAID assays to function in our laboratory. We conclude that when purchasing a field responder assay, there is large variation in the specificity of the assays, and a number of in-house tests must be performed to ensure functionality.
Kane-Gill, Sandra L; O'Connor, Michael F; Rothschild, Jeffrey M; Selby, Nicholas M; McLean, Barbara; Bonafide, Christopher P; Cvach, Maria M; Hu, Xiao; Konkani, Avinash; Pelter, Michele M; Winters, Bradford D
2017-09-01
To provide ICU clinicians with evidence-based guidance on tested interventions that reduce or prevent alert fatigue within clinical decision support systems. Systematic review of PubMed, Embase, SCOPUS, and CINAHL for relevant literature from 1966 to February 2017. Focus on critically ill patients and included evaluations in other patient care settings, as well. Identified interventions designed to reduce or prevent alert fatigue within clinical decision support systems. Study selection was based on one primary key question to identify effective interventions that attempted to reduce alert fatigue and three secondary key questions that covered the negative effects of alert fatigue, potential unintended consequences of efforts to reduce alert fatigue, and ideal alert quantity. Data were abstracted by two reviewers independently using a standardized abstraction tool. Surveys, meeting abstracts, "gray" literature, studies not available in English, and studies with non-original data were excluded. For the primary key question, articles were excluded if they did not provide a comparator as key question 1 was designed as a problem, intervention, comparison, and outcome question. We anticipated that reduction in alert fatigue, including the concept of desensitization may not be directly measured and thus considered interventions that reduced alert quantity as a surrogate marker for alert fatigue. Twenty-six articles met the inclusion criteria. Approaches for managing alert fatigue in the ICU are provided as a result of reviewing tested interventions that reduced alert quantity with the anticipated effect of reducing fatigue. Suggested alert management strategies include prioritizing alerts, developing sophisticated alerts, customizing commercially available alerts, and including end user opinion in alert selection. Alert fatigue itself is studied less frequently, as an outcome, and there is a need for more precise evaluation. Standardized metrics for alert fatigue is needed to advance the field. Suggestions for standardized metrics are provided in this document.
The FDA alert on suicidality and antiepileptic drugs: Fire or false alarm?
Hesdorffer, Dale C; Kanner, Andres M
2009-05-01
In January 2008, the U.S. Food and Drug Administration (FDA) issued an alert about an increased risk for suicidality in 199 clinical trials of 11 antiepileptic drugs (AEDs) for three different indications, including epilepsy. An advisory panel voted against a black-box warning on AED labels, and the FDA has accepted this recommendation. We discuss three potential problems with the alert. First, adverse event data were used rather than systematically collected data. Second, the 11 drugs grouped together as a single class of AEDs have different mechanisms of action and very different relative risks, many of which were not statistically significant and some of which were smaller than one. These facts suggest that they should not be grouped as a class. Third, the risk of adverse effects from uncontrolled seizures almost certainly outweighs the small risk of suicidality. We place our comments in the context of a review of the literature on suicidality and depression in epilepsy and the sparse literature on AEDs and suicidality. We recommend that all patients with epilepsy be routinely evaluated for depression, anxiety, and suicidality, and that future clinical trials include validated instruments to systematically assess these conditions to determine whether the possible signal observed by the FDA is real.
The interplay of attention economics and computer-aided detection marks in screening mammography
NASA Astrophysics Data System (ADS)
Schwartz, Tayler M.; Sridharan, Radhika; Wei, Wei; Lukyanchenko, Olga; Geiser, William; Whitman, Gary J.; Haygood, Tamara Miner
2016-03-01
Introduction: According to attention economists, overabundant information leads to decreased attention for individual pieces of information. Computer-aided detection (CAD) alerts radiologists to findings potentially associated with breast cancer but is notorious for creating an abundance of false-positive marks. We suspected that increased CAD marks do not lengthen mammogram interpretation time, as radiologists will selectively disregard these marks when present in larger numbers. We explore the relevance of attention economics in mammography by examining how the number of CAD marks affects interpretation time. Methods: We performed a retrospective review of bilateral digital screening mammograms obtained between January 1, 2011 and February 28, 2014, using only weekend interpretations to decrease distractions and the likelihood of trainee participation. We stratified data according to reader and used ANOVA to assess the relationship between number of CAD marks and interpretation time. Results: Ten radiologists, with median experience after residency of 12.5 years (range 6 to 24,) interpreted 1849 mammograms. When accounting for number of images, Breast Imaging Reporting and Data System category, and breast density, increasing numbers of CAD marks was correlated with longer interpretation time only for the three radiologists with the fewest years of experience (median 7 years.) Conclusion: For the 7 most experienced readers, increasing CAD marks did not lengthen interpretation time. We surmise that as CAD marks increase, the attention given to individual marks decreases. Experienced radiologists may rapidly dismiss larger numbers of CAD marks as false-positive, having learned that devoting extra attention to such marks does not improve clinical detection.
Chor, Josette S Y; Ngai, Karry LK; Goggins, William B; Wong, Martin C S; Wong, Samuel Y S; Lee, Nelson; Leung, Ting-fan; Rainer, Timothy H; Griffiths, Sian
2009-01-01
Objective To assess the acceptability of pre-pandemic influenza vaccination among healthcare workers in public hospitals in Hong Kong and the effect of escalation in the World Health Organization’s alert level for an influenza pandemic. Design Repeated cross sectional studies using self administered, anonymous questionnaires Setting Surveys at 31 hospital departments of internal medicine, paediatrics, and emergency medicine under the Hong Kong Hospital Authority from January to March 2009 and in May 2009 Participants 2255 healthcare workers completed the questionnaires in the two studies. They were doctors, nurses, or allied health professionals working in the public hospital system. Main outcome measures Stated willingness to accept pre-pandemic influenza vaccination (influenza A subtypes H5N1 or H1N1) and its associating factors. Results The overall willingness to accept pre-pandemic H5N1 vaccine was only 28.4% in the first survey, conducted at WHO influenza pandemic alert phase 3. No significant changes in the level of willingness to accept pre-pandemic H5N1 vaccine were observed despite the escalation to alert phase 5. The willingness to accept pre-pandemic H1N1 vaccine was 47.9% among healthcare workers when the WHO alert level was at phase 5. The most common reasons for an intention to accept were “wish to be protected” and “following health authority’s advice.” The major barriers identified were fear of side effects and doubts about efficacy. More than half of the respondents thought nurses should be the first priority group to receive the vaccines. The strongest positive associating factors were history of seasonal influenza vaccination and perceived risk of contracting the infection. Conclusions The willingness to accept pre-pandemic influenza vaccination was low, and no significant effect was observed with the change in WHO alert level. Further studies are required to elucidate the root cause of the low intention to accept pre-pandemic vaccination. PMID:19706937
Clinical Decision Support Alert Appropriateness: A Review and Proposal for Improvement
McCoy, Allison B.; Thomas, Eric J.; Krousel-Wood, Marie; Sittig, Dean F.
2014-01-01
Background Many healthcare providers are adopting clinical decision support (CDS) systems to improve patient safety and meet meaningful use requirements. Computerized alerts that prompt clinicians about drug-allergy, drug-drug, and drug-disease warnings or provide dosing guidance are most commonly implemented. Alert overrides, which occur when clinicians do not follow the guidance presented by the alert, can hinder improved patient outcomes. Methods We present a review of CDS alerts and describe a proposal to develop novel methods for evaluating and improving CDS alerts that builds upon traditional informatics approaches. Our proposal incorporates previously described models for predicting alert overrides that utilize retrospective chart review to determine which alerts are clinically relevant and which overrides are justifiable. Results Despite increasing implementations of CDS alerts, detailed evaluations rarely occur because of the extensive labor involved in manual chart reviews to determine alert and response appropriateness. Further, most studies have solely evaluated alert overrides that are appropriate or justifiable. Our proposal expands the use of web-based monitoring tools with an interactive dashboard for evaluating CDS alert and response appropriateness that incorporates the predictive models. The dashboard provides 2 views, an alert detail view and a patient detail view, to provide a full history of alerts and help put the patient's events in context. Conclusion The proposed research introduces several innovations to address the challenges and gaps in alert evaluations. This research can transform alert evaluation processes across healthcare settings, leading to improved CDS, reduced alert fatigue, and increased patient safety. PMID:24940129
Medication-related clinical decision support alert overrides in inpatients.
Nanji, Karen C; Seger, Diane L; Slight, Sarah P; Amato, Mary G; Beeler, Patrick E; Her, Qoua L; Dalleur, Olivia; Eguale, Tewodros; Wong, Adrian; Silvers, Elizabeth R; Swerdloff, Michael; Hussain, Salman T; Maniam, Nivethietha; Fiskio, Julie M; Dykes, Patricia C; Bates, David W
2018-05-01
To define the types and numbers of inpatient clinical decision support alerts, measure the frequency with which they are overridden, and describe providers' reasons for overriding them and the appropriateness of those reasons. We conducted a cross-sectional study of medication-related clinical decision support alerts over a 3-year period at a 793-bed tertiary-care teaching institution. We measured the rate of alert overrides, the rate of overrides by alert type, the reasons cited for overrides, and the appropriateness of those reasons. Overall, 73.3% of patient allergy, drug-drug interaction, and duplicate drug alerts were overridden, though the rate of overrides varied by alert type (P < .0001). About 60% of overrides were appropriate, and that proportion also varied by alert type (P < .0001). Few overrides of renal- (2.2%) or age-based (26.4%) medication substitutions were appropriate, while most duplicate drug (98%), patient allergy (96.5%), and formulary substitution (82.5%) alerts were appropriate. Despite warnings of potential significant harm, certain categories of alert overrides were inappropriate >75% of the time. The vast majority of duplicate drug, patient allergy, and formulary substitution alerts were appropriate, suggesting that these categories of alerts might be good targets for refinement to reduce alert fatigue. Almost three-quarters of alerts were overridden, and 40% of the overrides were not appropriate. Future research should optimize alert types and frequencies to increase their clinical relevance, reducing alert fatigue so that important alerts are not inappropriately overridden.
Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting
Harrison, Andrew M.; Thongprayoon, Charat; Aakre, Christopher A.; Jeng, Jack Y.; Dziadzko, Mikhail A.; Gajic, Ognjen; Pickering, Brian W.
2017-01-01
Background Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. Objective To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. Study Design In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. Results The alert acknowledgement rate from the severe sepsis alert system was 3% (N = 148) and 51% (N = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min (N = 5) and median 2 min (N = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Conclusion Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting. PMID:28316887
Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting.
Harrison, Andrew M; Thongprayoon, Charat; Aakre, Christopher A; Jeng, Jack Y; Dziadzko, Mikhail A; Gajic, Ognjen; Pickering, Brian W; Herasevich, Vitaly
2017-01-01
Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. The alert acknowledgement rate from the severe sepsis alert system was 3% ( N = 148) and 51% ( N = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min ( N = 5) and median 2 min ( N = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting.
The Third Swift Burst Alert Telescope Gamma-Ray Burst Catalog
NASA Astrophysics Data System (ADS)
Lien, Amy; Sakamoto, Takanori; Barthelmy, Scott D.; Baumgartner, Wayne H.; Cannizzo, John K.; Chen, Kevin; Collins, Nicholas R.; Cummings, Jay R.; Gehrels, Neil; Krimm, Hans A.; Markwardt, Craig. B.; Palmer, David M.; Stamatikos, Michael; Troja, Eleonora; Ukwatta, T. N.
2016-09-01
To date, the Burst Alert Telescope (BAT) onboard Swift has detected ˜1000 gamma-ray bursts (GRBs), of which ˜360 GRBs have redshift measurements, ranging from z = 0.03 to z = 9.38. We present the analyses of the BAT-detected GRBs for the past ˜11 years up through GRB 151027B. We report summaries of both the temporal and spectral analyses of the GRB characteristics using event data (I.e., data for each photon within approximately 250 s before and 950 s after the BAT trigger time), and discuss the instrumental sensitivity and selection effects of GRB detections. We also explore the GRB properties with redshift when possible. The result summaries and data products are available at http://swift.gsfc.nasa.gov/results/batgrbcat/index.html. In addition, we perform searches for GRB emissions before or after the event data using the BAT survey data. We estimate the false detection rate to be only one false detection in this sample. There are 15 ultra-long GRBs (˜2% of the BAT GRBs) in this search with confirmed emission beyond ˜1000 s of event data, and only two GRBs (GRB 100316D and GRB 101024A) with detections in the survey data prior to the starting of event data.
THE THIRD SWIFT BURST ALERT TELESCOPE GAMMA-RAY BURST CATALOG
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lien, Amy; Baumgartner, Wayne H.; Cannizzo, John K.
2016-09-20
To date, the Burst Alert Telescope (BAT) onboard Swift has detected ∼1000 gamma-ray bursts (GRBs), of which ∼360 GRBs have redshift measurements, ranging from z = 0.03 to z = 9.38. We present the analyses of the BAT-detected GRBs for the past ∼11 years up through GRB 151027B. We report summaries of both the temporal and spectral analyses of the GRB characteristics using event data (i.e., data for each photon within approximately 250 s before and 950 s after the BAT trigger time), and discuss the instrumental sensitivity and selection effects of GRB detections. We also explore the GRB propertiesmore » with redshift when possible. The result summaries and data products are available at http://swift.gsfc.nasa.gov/results/batgrbcat/index.html. In addition, we perform searches for GRB emissions before or after the event data using the BAT survey data. We estimate the false detection rate to be only one false detection in this sample. There are 15 ultra-long GRBs (∼2% of the BAT GRBs) in this search with confirmed emission beyond ∼1000 s of event data, and only two GRBs (GRB 100316D and GRB 101024A) with detections in the survey data prior to the starting of event data.« less
Influenza surveillance in Europe: establishing epidemic thresholds by the Moving Epidemic Method
Vega, Tomás; Lozano, Jose Eugenio; Meerhoff, Tamara; Snacken, René; Mott, Joshua; Ortiz de Lejarazu, Raul; Nunes, Baltazar
2012-01-01
Please cite this paper as: Vega et al. (2012) Influenza surveillance in Europe: establishing epidemic thresholds by the moving epidemic method. Influenza and Other Respiratory Viruses 7(4), 546–558. Background Timely influenza surveillance is important to monitor influenza epidemics. Objectives (i) To calculate the epidemic threshold for influenza‐like illness (ILI) and acute respiratory infections (ARI) in 19 countries, as well as the thresholds for different levels of intensity. (ii) To evaluate the performance of these thresholds. Methods The moving epidemic method (MEM) has been developed to determine the baseline influenza activity and an epidemic threshold. False alerts, detection lags and timeliness of the detection of epidemics were calculated. The performance was evaluated using a cross‐validation procedure. Results The overall sensitivity of the MEM threshold was 71·8% and the specificity was 95·5%. The median of the timeliness was 1 week (range: 0–4·5). Conclusions The method produced a robust and specific signal to detect influenza epidemics. The good balance between the sensitivity and specificity of the epidemic threshold to detect seasonal epidemics and avoid false alerts has advantages for public health purposes. This method may serve as standard to define the start of the annual influenza epidemic in countries in Europe. PMID:22897919
Balaguera, Henri U; Wise, Diana; Ng, Chun Yin; Tso, Han-Wen; Chiang, Wan-Lin; Hutchinson, Aimee M; Galvin, Tracy; Hilborne, Lee; Hoffman, Cathy; Huang, Chi-Cheng; Wang, C Jason
2017-05-04
Hospitalized patients in the United States experience falls at a rate of 2.6 to 17.1 per 1000 patient-days, with the majority occurring when a patient is moving to, from, and around the bed. Each fall with injury costs an average of US $14,000. The aim was to conduct a technology evaluation, including feasibility, usability, and user experience, of a medical sensor-based Intranet of things (IoT) system in facilitating nursing response to bed exits in an acute care hospital. Patients 18 years and older with a Morse fall score of 45 or greater were recruited from a 35-bed medical-surgical ward in a 317-bed Massachusetts teaching hospital. Eligible patients were recruited between August 4, 2015 and July 31, 2016. Participants received a sensor pad placed between the top of their mattress and bed sheet. The sensor pad was positioned to monitor movement from patients' shoulders to their thighs. The SensableCare System was evaluated for monitoring patient movement and delivering timely alerts to nursing staff via mobile devices when there appeared to be a bed-exit attempt. Sensor pad data were collected automatically from the system. The primary outcomes included number of falls, time to turn off bed-exit alerts, and the number of attempted bed-exit events. Data on patient falls were collected by clinical research assistants and confirmed with the unit nurse manager. Explanatory variables included room locations (zones 1-3), day of the week, nursing shift, and Morse Fall Scale (ie, positive fall history, positive secondary diagnosis, positive ambulatory aid, weak impaired gait/transfer, positive IV/saline lock, mentally forgets limitations). We also assessed user experience via nurse focus groups. Qualitative data regarding staff interactions with the system were collected during two focus groups with 25 total nurses, each lasting approximately 1.5 hours. A total of 91 patients used the system for 234.0 patient-days and experienced no bed falls during the study period. On average, patients were assisted/returned to bed 46 seconds after the alert system was triggered. Response times were longer during the overnight nursing shift versus day shift (P=.005), but were independent of the patient's location on the unit. Focus groups revealed that nurses found the system integrated well into the clinical nursing workflow and the alerts were helpful in patient monitoring. A medical IoT system can be integrated into the existing nursing workflow and may reduce patient bed fall risk in acute care hospitals, a high priority but an elusive patient safety challenge. By using an alerting system that sends notifications directly to nurses' mobile devices, nurses can equally respond to unassisted bed-exit attempts wherever patients are located on the ward. Further study, including a fully powered randomized controlled trial, is needed to assess effectiveness across hospital settings. ©Henri U Balaguera, Diana Wise, Chun Yin Ng, Han-Wen Tso, Wan-Lin Chiang, Aimee M Hutchinson, Tracy Galvin, Lee Hilborne, Cathy Hoffman, Chi-Cheng Huang, C Jason Wang. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 04.05.2017.
Tamblyn, Robyn; Reidel, Kristen; Patel, Vaishali
2012-01-01
Objective Computerised drug alerts are expected to reduce patients’ risk of adverse drug events. However, physicians over-ride most drug alerts, because they believe that the benefit exceeds the risk. The purpose of this study was to determine the drug alert, patient and physician characteristics associated with the: (1) occurrence of psychotropic drug alerts for elderly patients and the (2) response to these alerts by their primary care physicians. Setting Primary care, Quebec, Canada. Design Prospective cohort study. Participants Sixty-one physicians using an electronic prescribing and drug alert decision-support system in their practice, and 3413 elderly patients using psychotropic drugs. Primary and secondary measures Psychotropic drug class, alert severity, patient risk for fall injuries and physician experience, practice volume and computer use were evaluated in relationship to the likelihood of having: (1) a psychotropic drug alert, (2) the prescription revised in response to an alert. Cluster-adjusted alternating logistic regression was used to assess multilevel predictors of alert occurrence and response. Results In total 13 080 psychotropic drug alerts were generated in 8931 visits. Alerts were more likely to be generated for male patients at higher risk of fall-related injury and for physicians who established the highest alert threshold. In 9.9% of alerts seen, the prescription was revised. The highest revision rate was for antipsychotic alerts (22.6%). Physicians were more likely to revise prescriptions for severe alerts (OR 2.03; 95%CI 1.39 to 2.98), if patients had cognitive impairment (OR 1.95; 95%CI 1.13 to 3.36), and if they made more visits to their physician (OR 1.05 per 5 visits; 95%CI 1 to 1.09). Conclusions Physicians view and respond to a small proportion of alerts, mainly for higher-risk patients. To reduce the risk of psychotropic drug-related fall injuries, a new generation of evidence-based drug alerts should be developed. PMID:23024254
Differential effects of phasic and tonic alerting on the efficiency of executive attention.
Asanowicz, Dariusz; Marzecová, Anna
2017-05-01
The study examined how alerting and executive attention interact in a task involving conflict resolution. We proposed a tentative scenario in which an initial exogenous phasic alerting phase is followed by an endogenous tonic alerting phase, and hypothesized that these two processes may have distinct effects on conflict resolution. Phasic alerting was expected to increase the conflict, whereas tonic alerting was expected to decrease the conflict. Three experiments were conducted using different variants of the flanker task with visual alerting cues and varied cue-target intervals (SOA), to differentiate between effects of phasic alerting (short SOA) and tonic alerting (long SOA). The results showed that phasic alerting consistently decreased the efficiency of conflict resolution indexed by response time and accuracy, whereas tonic alerting increased the accuracy of conflict resolution, but at a cost in the speed of processing the conflict. The third experiment additionally showed that the effects of phasic alerting may be modulated by the psychophysical strength of alerting cues. Discussed are possible mechanisms that could account for the observed interactions between alerting and conflict resolution, as well as some discrepancies between the current and previous studies. Copyright © 2017 Elsevier B.V. All rights reserved.
GPS: Shaping Student Success One Conversation at a Time
ERIC Educational Resources Information Center
Star, Mikhael; Collette, Lanita
2010-01-01
Increasing instructor-student interactions and improving support personnel interventions with students positively affects their academic performance, retention, and graduation rates. This article discusses the Grade Performance Status (GPS) which is Northern Arizona University's new online, academic early alert tool for increasing instructor…
Evaluation of health alerts from an early illness warning system in independent living.
Rantz, Marilyn J; Scott, Susan D; Miller, Steven J; Skubic, Marjorie; Phillips, Lorraine; Alexander, Greg; Koopman, Richelle J; Musterman, Katy; Back, Jessica
2013-06-01
Passive sensor networks were deployed in independent living apartments to monitor older adults in their home environments to detect signs of impending illness and alert clinicians so they can intervene and prevent or delay significant changes in health or functional status. A retrospective qualitative deductive content analysis was undertaken to refine health alerts to improve clinical relevance to clinicians as they use alerts in their normal workflow of routine care delivery to older adults. Clinicians completed written free-text boxes to describe actions taken (or not) as a result of each alert; they also rated the clinical significance (relevance) of each health alert on a scale of 1 to 5. Two samples of the clinician's written responses to the health alerts were analyzed after alert algorithms had been adjusted based on results of a pilot study using health alerts to enhance clinical decision-making. In the first sample, a total of 663 comments were generated by seven clinicians in response to 385 unique alerts; there are more comments than alerts because more than one clinician rated the same alert. The second sample had a total of 142 comments produced by three clinicians in response to 88 distinct alerts. The overall clinical relevance of the alerts, as judged by the content of the qualitative comments by clinicians for each alert, improved from 33.3% of the alerts in the first sample classified as clinically relevant to 43.2% in the second. The goal is to produce clinically relevant alerts that clinicians find useful in daily practice. The evaluation methods used are described to assist others as they consider building and iteratively refining health alerts to enhance clinical decision making.
An IDS Alerts Aggregation Algorithm Based on Rough Set Theory
NASA Astrophysics Data System (ADS)
Zhang, Ru; Guo, Tao; Liu, Jianyi
2018-03-01
Within a system in which has been deployed several IDS, a great number of alerts can be triggered by a single security event, making real alerts harder to be found. To deal with redundant alerts, we propose a scheme based on rough set theory. In combination with basic concepts in rough set theory, the importance of attributes in alerts was calculated firstly. With the result of attributes importance, we could compute the similarity of two alerts, which will be compared with a pre-defined threshold to determine whether these two alerts can be aggregated or not. Also, time interval should be taken into consideration. Allowed time interval for different types of alerts is computed individually, since different types of alerts may have different time gap between two alerts. In the end of this paper, we apply proposed scheme on DAPRA98 dataset and the results of experiment show that our scheme can efficiently reduce the redundancy of alerts so that administrators of security system could avoid wasting time on useless alerts.
Alertness and cognitive control: Toward a spatial grouping hypothesis.
Schneider, Darryl W
2018-05-01
A puzzling interaction involving alertness and cognitive control is indicated by the finding of faster performance but larger congruency effects on alert trials (on which alerting cues are presented before the task stimuli) than on no-alert trials in selective attention tasks. In the present study, the author conducted four experiments to test hypotheses about the interaction. Manipulation of stimulus spacing revealed a difference in congruency effects between alert and no-alert trials for narrowly spaced stimuli but not for widely spaced stimuli, inconsistent with the hypothesis that increased alertness is associated with more diffuse attention. Manipulation of color grouping revealed similar differences in congruency effects between alert and no-alert trials for same-color and different-color groupings of targets and distractors, inconsistent with the general hypothesis that increased alertness is associated with more perceptual grouping. To explain the results, the author proposes that increased alertness is associated specifically with more spatial grouping of stimuli, possibly by modulating the threshold for parsing stimulus displays into distinct objects.
Managing the Alert Process at NewYork-Presbyterian Hospital
Kuperman, Gilad J; Diamente, Rosanna; Khatu, Vrinda; Chan-Kraushar, Terri; Stetson, Pete; Boyer, Aurelia; Cooper, Mary
2005-01-01
Clinical decision support can improve the quality of care, but requires substantial knowledge management activities. At NewYork-Presbyterian Hospital in New York City, we have implemented a formal alert management process whereby only hospital committees and departments can request alerts. An explicit requestor, who will help resolve the details of the alert logic and the alert message must be identified. Alerts must be requested in writing using a structured alert request form. Alert requests are reviewed by the Alert Committee and then forwarded to the Information Systems department for a software development estimate. The model required that clinical committees and departments become more actively involved in the development of alerts than had previously been necessary. In the 12 months following implementation, 10 alert requests were received. The model has been well received. A lot of the knowledge engineering work has been distributed and burden has been removed from scarce medical informatics resources. PMID:16779073
Optimizing drug-dose alerts using commercial software throughout an integrated health care system.
Saiyed, Salim M; Greco, Peter J; Fernandes, Glenn; Kaelber, David C
2017-11-01
All default electronic health record and drug reference database vendor drug-dose alerting recommendations (single dose, daily dose, dose frequency, and dose duration) were silently turned on in inpatient, outpatient, and emergency department areas for pediatric-only and nonpediatric-only populations. Drug-dose alerts were evaluated during a 3-month period. Drug-dose alerts fired on 12% of orders (104 098/834 911). System-level and drug-specific strategies to decrease drug-dose alerts were analyzed. System-level strategies included: (1) turning off all minimum drug-dosing alerts, (2) turning off all incomplete information drug-dosing alerts, (3) increasing the maximum single-dose drug-dose alert threshold to 125%, (4) increasing the daily dose maximum drug-dose alert threshold to 125%, and (5) increasing the dose frequency drug-dose alert threshold to more than 2 doses per day above initial threshold. Drug-specific strategies included changing drug-specific maximum single and maximum daily drug-dose alerting parameters for the top 22 drug categories by alert frequency. System-level approaches decreased alerting to 5% (46 988/834 911) and drug-specific approaches decreased alerts to 3% (25 455/834 911). Drug-dose alerts varied between care settings and patient populations. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Investigation into the Value of Trained Glycaemia Alert Dogs to Clients with Type I Diabetes
Rooney, Nicola J.; Morant, Steve; Guest, Claire
2013-01-01
Previous studies have suggested that some pet dogs respond to their owners’ hypoglycaemic state. Here, we show that trained glycaemia alert dogs placed with clients living with diabetes afford significant improvements to owner well-being. We investigated whether trained dogs reliably respond to their owners’ hypoglycaemic state, and whether owners experience facilitated tightened glycaemic control, and wider psychosocial benefits. Since obtaining their dog, all seventeen clients studied reported positive effects including reduced paramedic call outs, decreased unconscious episodes and improved independence. Owner-recorded data showed that dogs alerted their owners, with significant, though variable, accuracy at times of low and high blood sugar. Eight out of the ten dogs (for which owners provided adequate records) responded consistently more often when their owner’s blood sugars were reported to be outside, than within, target range. Comparison of nine clients’ routine records showed significant overall change after obtaining their dogs, with seven clients recording a significantly higher proportion of routine tests within target range after obtaining a dog. HbA1C showed a small, non significant reduction after dog allocation. Based on owner-reported data we have shown, for the first time, that trained detection dogs perform above chance level. This study points to the potential value of alert dogs, for increasing glycaemic control, client independence and consequent quality of life and even reducing the costs of long-term health care. PMID:23950905
iFall: an Android application for fall monitoring and response.
Sposaro, Frank; Tyson, Gary
2009-01-01
Injuries due to falls are among the leading causes of hospitalization in elderly persons, often resulting in a rapid decline in quality of life or death. Rapid response can improve the patients outcome, but this is often lacking when the injured person lives alone and the nature of the injury complicates calling for help. This paper presents an alert system for fall detection using common commercially available electronic devices to both detect the fall and alert authorities. We use an Android-based smart phone with an integrated tri-axial accelerometer. Data from the accelerometer is evaluated with several threshold based algorithms and position data to determine a fall. The threshold is adaptive based on user provided parameters such as: height, weight, and level of activity. The algorithm adapts to unique movements that a phone experiences as opposed to similar systems which require users to mount accelerometers to their chest or trunk. If a fall is suspected a notification is raised requiring the user's response. If the user does not respond, the system alerts pre-specified social contacts with an informational message via SMS. If a contact responds the system commits an audible notification, automatically connects, and enables the speakerphone. If a social contact confirms a fall, an appropriate emergency service is alerted. Our system provides a realizable, cost effective solution to fall detection using a simple graphical interface while not overwhelming the user with uncomfortable sensors.
Prescription order risk factors for pediatric dosing alerts.
Stultz, J S; Porter, K; Nahata, M C
2015-02-01
To determine dosing alert rates based on prescription order characteristics and identify prescription order risk factors for the occurrence of dosing alerts. A retrospective analysis of inpatient medication orders and dosing alerts occurring during October 2011 and January, April, and July 2012 at a pediatric institution. Prescription orders and alerts were categorized by: medication class, patient age, route of administration, and month of the year. There were 228,259 orders during the studied period, with 11,072 alerted orders (4.9%). The most frequently alerted medication class was the non-analgesic central nervous system agent class (14% of alerts). Age, route, medication class, and month all independently affected dosing alert rates. The alert rate was highest for immunosuppressive agents (54%), neonates (6.7%), and orders for rectal administration (9.5%). The alert rate was higher in adult patients receiving their care at a pediatric institution (5.7%) compared to children (4.7%), but after multivariate analysis, pediatric orders had higher odds for an alert (OR 1.1, 95% CI 1.05-1.16). Mercaptopurine had the highest alert rate when categorized by active ingredient (73.9%). Albuterol 2.5mg/mL continuous aerosol and heparin 1000 units in 0.9% sodium chloride injection solution were the unique medications with the highest alert rates (100.0% and 97.7%, respectively). Certain types of prescription orders have a higher risk for causing dosing alerts than others. Patient age, medication class, route of administration, and the month of year can affect dosing alert rates. Design and customization efforts should focus on these medications and prescription order characteristics that increase the risk for dosing alerts. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Evaluation of Antimicrobial Stewardship-Related Alerts Using a Clinical Decision Support System.
Ghamrawi, Riane J; Kantorovich, Alexander; Bauer, Seth R; Pallotta, Andrea M; Sekeres, Jennifer K; Gordon, Steven M; Neuner, Elizabeth A
2017-11-01
Background: Information technology, including clinical decision support systems (CDSS), have an increasingly important and growing role in identifying opportunities for antimicrobial stewardship-related interventions. Objective: The aim of this study was to describe and compare types and outcomes of CDSS-built antimicrobial stewardship alerts. Methods: Fifteen alerts were evaluated in the initial antimicrobial stewardship program (ASP) review. Preimplementation, alerts were reviewed retrospectively. Postimplementation, alerts were reviewed in real-time. Data collection included total number of actionable alerts, recommendation acceptance rates, and time spent on each alert. Time to de-escalation to narrower spectrum agents was collected. Results: In total, 749 alerts were evaluated. Overall, 306 (41%) alerts were actionable (173 preimplementation, 133 postimplementation). Rates of actionable alerts were similar for custom-built and prebuilt alert types (39% [53 of 135] vs 41% [253 of 614], P = .68]. In the postimplementation group, an intervention was attempted in 97% of actionable alerts and 70% of interventions were accepted. The median time spent per alert was 7 minutes (interquartile range [IQR], 5-13 minutes; 15 [12-17] minutes for actionable alerts vs 6 [5-7] minutes for nonactionable alerts, P < .001). In cases where the antimicrobial was eventually de-escalated, the median time to de-escalation was 28.8 hours (95% confidence interval [CI], 10.0-69.1 hours) preimplementation vs 4.7 hours (95% CI, 2.4-22.1 hours) postimplementation, P < .001. Conclusions: CDSS have played an important role in ASPs to help identify opportunities to optimize antimicrobial use through prebuilt and custom-built alerts. As ASP roles continue to expand, focusing time on customizing institution specific alerts will be of vital importance to help redistribute time needed to manage other ASP tasks and opportunities.
Polybrominated diphenyl ethers (PBDEs) fall into the class of compounds known as brominated flame retardants and their incorporation in a multitude of products is responsible for saving numerous lives. However, toxicology studies have alerted researchers to the potential adverse...
Mitigating runway incursions : a safety benefits assessment of airport surface moving map displays
DOT National Transportation Integrated Search
2010-01-01
Airport surface moving maps vary in the capabilities provided (e.g., the depiction of ownship position and/or traffic, the presentation of taxi route, and indicating or alerting the potential for runway incursions). The purpose of this effort was to ...
Simpao, Allan F; Ahumada, Luis M; Desai, Bimal R; Bonafide, Christopher P; Gálvez, Jorge A; Rehman, Mohamed A; Jawad, Abbas F; Palma, Krisha L; Shelov, Eric D
2015-03-01
To develop and evaluate an electronic dashboard of hospital-wide electronic health record medication alerts for an alert fatigue reduction quality improvement project. We used visual analytics software to develop the dashboard. We collaborated with the hospital-wide Clinical Decision Support committee to perform three interventions successively deactivating clinically irrelevant drug-drug interaction (DDI) alert rules. We analyzed the impact of the interventions on care providers' and pharmacists' alert and override rates using an interrupted time series framework with piecewise regression. We evaluated 2 391 880 medication alerts between January 31, 2011 and January 26, 2014. For pharmacists, the median alert rate prior to the first DDI deactivation was 58.74 alerts/100 orders (IQR 54.98-60.48) and 25.11 alerts/100 orders (IQR 23.45-26.57) following the three interventions (p<0.001). For providers, baseline median alert rate prior to the first round of DDI deactivation was 19.73 alerts/100 orders (IQR 18.66-20.24) and 15.11 alerts/100 orders (IQR 14.44-15.49) following the three interventions (p<0.001). In a subgroup analysis, we observed a decrease in pharmacists' override rates for DDI alerts that were not modified in the system from a median of 93.06 overrides/100 alerts (IQR 91.96-94.33) to 85.68 overrides/100 alerts (IQR 84.29-87.15, p<0.001). The medication serious safety event rate decreased during the study period, and there were no serious safety events reported in association with the deactivated alert rules. An alert dashboard facilitated safe rapid-cycle reductions in alert burden that were temporally associated with lower pharmacist override rates in a subgroup of DDIs not directly affected by the interventions; meanwhile, the pharmacists' frequency of selecting the 'cancel' option increased. We hypothesize that reducing the alert burden enabled pharmacists to devote more attention to clinically relevant alerts. © The Author 2014. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Rogers, Peter J; Martin, James; Smith, Chloe; Heatherley, Susan V; Smit, Hendrik J
2003-04-01
The extent to which the measured (and felt) psychostimulant effects of caffeine represent a real benefit of caffeine consumption or merely withdrawal reversal is unclear. Results showing positive psychostimulant effects of acute caffeine administration in habitual non-consumers of caffeine would provide evidence for a net benefit of caffeine unconfounded by withdrawal. To compare the mood, alerting, psychomotor and reinforcing effects of caffeine in caffeine non-consumers and acutely (overnight) withdrawn caffeine consumers. In experiment 1, these participants consumed two differently flavoured drinks, one containing 100 mg caffeine and the other containing no caffeine. Each drink was consumed on 4 separate days in semi-random order, and self-ratings of mood and alertness were completed before and after drink consumption. On day 9, both drinks contained 50 mg caffeine and drink preference (choice) and intake were assessed. In experiment 2, mood, alertness and performance on a long-duration simple reaction time task were assessed before and after administration of 100 mg or placebo in a single test session. Prior to receiving caffeine, the (overnight withdrawn) caffeine consumers were less alert and more tense than the non-consumers. Caffeine only had significant reinforcing, mood and psychomotor performance effects in the caffeine consumers. The reinforcing effect of caffeine was evident from an effect on drink intake, but drink choice was unaffected. Caffeine increased self-rated alertness of both caffeine consumers and non-consumers; however, for some of the non-consumers this was associated with a worsening of performance. These results support the hypothesis that the psychostimulant and related effects of caffeine are due largely to withdrawal reversal.
Zijlstra, Jolande A; Beesems, Stefanie G; De Haan, Rob J; Koster, Rudolph W
2015-07-01
We studied the short-term psychological impact and post-traumatic stress disorder (PTSD)-related symptoms in lay rescuers performing cardiopulmonary resuscitation (CPR) after a text message (TM)-alert for out-of-hospital-cardiac arrest, and assessed which factors contribute to a higher level of PTSD-related symptoms. The lay rescuers received a TM-alert and simultaneously an email with a link to an online questionnaire. We analyzed all questionnaires from February 2013 until October 2014 measuring the short-term psychological impact. We interviewed by telephone all first arriving lay rescuers performing bystander CPR and assessed PTSD-related symptoms with the Impact of Event Scale (IES) 4-6 weeks after the resuscitation. IES-scores 0-8 reflected no stress, 9-25 mild, 26-43 moderate, and 44-75 severe stress. A score ≥ 26 indicated PTSD symptomatology. Of all alerted lay rescuers, 6572 completed the online questionnaire. Of these, 1955 responded to the alert and 507 assisted in the resuscitation. We interviewed 203 first arriving rescuers of whom 189 completed the IES. Of these, 41% perceived no/mild short-term impact, 46% bearable impact and 13% severe impact. On the IES, 81% scored no stress and 19% scored mild stress. None scored moderate or severe stress. Using a multivariable logistic regression model we identified three factors with an independent impact on mild stress level: no automated external defibrillator connected by the lay rescuer, severe short-term impact, and no (very) positive experience. Lay rescuers alerted by text messages, do not show PTSD-related symptoms 4-6 weeks after performing bystander CPR, even if they perceive severe short-term psychological impact. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Provider management strategies of abnormal test result alerts: a cognitive task analysis.
Hysong, Sylvia J; Sawhney, Mona K; Wilson, Lindsay; Sittig, Dean F; Espadas, Donna; Davis, Traber; Singh, Hardeep
2010-01-01
Electronic medical records (EMRs) facilitate abnormal test result communication through "alert" notifications. The aim was to evaluate how primary care providers (PCPs) manage alerts related to critical diagnostic test results on their EMR screens, and compare alert-management strategies of providers with high versus low rates of timely follow-up of results. 28 PCPs from a large, tertiary care Veterans Affairs Medical Center (VAMC) were purposively sampled according to their rates of timely follow-up of alerts, determined in a previous study. Using techniques from cognitive task analysis, participants were interviewed about how and when they manage alerts, focusing on four alert-management features to filter, sort and reduce unnecessary alerts on their EMR screens. Provider knowledge of alert-management features ranged between 4% and 75%. Almost half (46%) of providers did not use any of these features, and none used more than two. Providers with higher versus lower rates of timely follow-up used the four features similarly, except one (customizing alert notifications). Providers with low rates of timely follow-up tended to manually scan the alert list and process alerts heuristically using their clinical judgment. Additionally, 46% of providers used at least one workaround strategy to manage alerts. Considerable heterogeneity exists in provider use of alert-management strategies; specific strategies may be associated with lower rates of timely follow-up. Standardization of alert-management strategies including improving provider knowledge of appropriate tools in the EMR to manage alerts could reduce the lack of timely follow-up of abnormal diagnostic test results.
Dose-response association between salivary cotinine levels and Mycobacterium tuberculosis infection.
Shin, S S; Laniado-Laborin, R; Moreno, P G; Novotny, T E; Strathdee, S A; Garfein, R S
2013-11-01
Tijuana, Mexico. To describe the association between salivary cotinine levels and interferon-gamma (IFN-γ) release assay results. We conducted a cross-sectional study among injection drug users. Salivary cotinine levels were measured using NicAlert, a semi-quantitative dipstick assay. QuantiFERON©-TB Gold In-Tube (QFT-GIT) was used to determine Mycobacterium tuberculosis infection. Among 234 participants, the prevalence of QFT-GIT positivity for NicAlert cotinine categories 0 (non-smoking), 1 (second-hand smoke exposure or low-level smoking) and 26 (regular smoking) were respectively 42.1%, 46.4% and 65.2% (Ptrend 0.012). We found increasing trends in QFT-GIT positivity (Ptrend 0.003) and IFN-γ concentrations (Spearman's r 0.200, P 0.002) across cotinine levels 0 to 6. In multivariable log-binomial regression models adjusted for education, cotinine levels were not associated with QFT-GIT positivity when included as smoking categories (1 and 26 vs. 0), but were independently associated with QFT-GIT positivity when included as an ordinal variable (prevalence ratio 1.09 per 1 cotinine level, 95%CI 1.021.16). Our findings suggest that a dose-response relationship exists between tobacco smoke exposure and M. tuberculosis infection. Longitudinal studies that use biochemical measures for smoking status are needed to confirm our findings.
Chewing and Attention: A Positive Effect on Sustained Attention
Onozuka, Minoru
2015-01-01
Chewing is crushing food not only to aid swallowing and digestion, but also to help stress relief and regulate cognitive function, especially in attention. It is well known that chewing gum is used for sleepiness prevention during work, learning, and driving, suggesting a link between chewing and sustained attention. We hypothesized that chewing elevates attention and/or alertness, leading to improvements in cognitive performance. We carried out a systematic review of the PubMed database. We inspected the attributes of effects on attention in studies investigating the effects of chewing on attention or alertness conducted with pre-post design in healthy subjects, except elderly. We identified 151 references, 22 of which were included: 14 (64%) showed positive attributes of effects on attention, 1 (5%) showed negative attributes of effects on attention, 5 (23%) showed both positive and negative attributes of effects on attention, and 2 (9%) showed no significant attributes of effects on attention. Thus, positive attributes of effects of chewing on attention, especially on sustained attention, were shown in over half of the reports. These effects also appeared with improvement in mood and stress relief and were influenced by time-on-task effect. Further studies are needed, but chewing could be useful for modifying cognitive function. PMID:26075234
Hildebrand, Patricia; Königschulte, Werner; Gaber, Tilman Jakob; Bubenzer-Busch, Sarah; Helmbold, Katrin; Biskup, Caroline Sarah; Langen, Karl-Josef; Fink, Gereon Rudolf; Zepf, Florian Daniel
2015-01-01
The synthesis of the neurotransmitters serotonin (5-HT) and dopamine (DA) in the brain can be directly altered by dietary manipulation of their relevant precursor amino acids (AA). There is evidence that altered serotonergic and dopaminergic neurotransmission are both associated with impaired attentional control. Specifically, phasic alertness is one specific aspect of attention that has been linked to changes in 5-HT and DA availability in different neurocircuitries related to attentional processes. The present study investigated the impact of short-term reductions in central nervous system 5-HT and DA synthesis, which was achieved by dietary depletion of the relevant precursor AA, on phasic alertness in healthy adult volunteers; body weight-adapted dietary tryptophan and phenylalanine-tyrosine depletion (PTD) techniques were used. The study employed a double-blind between-subject design. Fifty healthy male and female subjects were allocated to three groups in a randomized and counterbalanced manner and received three different dietary challenge conditions: acute tryptophan depletion (ATD, for the depletion of 5-HT; N=16), PTD (for the depletion of DA; N=17), and a balanced AA load (BAL; N=17), which served as a control condition. Three hours after challenge intake (ATD/PTD/BAL), phasic alertness was assessed using a standardized test battery for attentional performance (TAP). Blood samples for AA level analyses were obtained at baseline and 360 min after the challenge intake. Overall, there were no significant differences in phasic alertness for the different challenge conditions. Regarding PTD administration, a positive correlation between the reaction times and the DA-related depletion magnitude was detected via the lower plasma tyrosine levels and the slow reaction times of the first run of the task. In contrast, higher tryptophan concentrations were associated with slower reaction times in the fourth run of the task in the same challenge group. The present study is the first to demonstrate preliminary data that support an association between decreased central nervous system DA synthesis, which was achieved by dietary depletion strategies, and slower reaction times in specific runs of a task designed to assess phasic alertness in healthy adult volunteers; these findings are consistent with previous evidence that links phasic alertness with dopaminergic neurotransmission. A lack of significant differences between the three groups could be due to compensatory mechanisms and the limited sample size, as well as the dietary challenge procedures administered to healthy participants and the strict exclusion criteria used. The potential underlying neurochemical processes related to phasic alertness should be the subject of further investigations.
Matheny, Michael E; Normand, Sharon-Lise T; Gross, Thomas P; Marinac-Dabic, Danica; Loyo-Berrios, Nilsa; Vidi, Venkatesan D; Donnelly, Sharon; Resnic, Frederic S
2011-12-14
Automated adverse outcome surveillance tools and methods have potential utility in quality improvement and medical product surveillance activities. Their use for assessing hospital performance on the basis of patient outcomes has received little attention. We compared risk-adjusted sequential probability ratio testing (RA-SPRT) implemented in an automated tool to Massachusetts public reports of 30-day mortality after isolated coronary artery bypass graft surgery. A total of 23,020 isolated adult coronary artery bypass surgery admissions performed in Massachusetts hospitals between January 1, 2002 and September 30, 2007 were retrospectively re-evaluated. The RA-SPRT method was implemented within an automated surveillance tool to identify hospital outliers in yearly increments. We used an overall type I error rate of 0.05, an overall type II error rate of 0.10, and a threshold that signaled if the odds of dying 30-days after surgery was at least twice than expected. Annual hospital outlier status, based on the state-reported classification, was considered the gold standard. An event was defined as at least one occurrence of a higher-than-expected hospital mortality rate during a given year. We examined a total of 83 hospital-year observations. The RA-SPRT method alerted 6 events among three hospitals for 30-day mortality compared with 5 events among two hospitals using the state public reports, yielding a sensitivity of 100% (5/5) and specificity of 98.8% (79/80). The automated RA-SPRT method performed well, detecting all of the true institutional outliers with a small false positive alerting rate. Such a system could provide confidential automated notification to local institutions in advance of public reporting providing opportunities for earlier quality improvement interventions.
The NAS Alert System: A look at the first eight years
Fuller, Pamela L.; Neilson, Matt; Huge, Dane H.
2013-01-01
The U.S. Geological Survey's Nonindigenous Aquatic Species (NAS) database program (http://nas.er.usgs.gov) tracks the distribution of introduced aquatic organisms across the United States. Awareness of, and timely response to, novel species introductions by those involved in nonindigenous aquatic species management and research requires a framework for rapid dissemination of occurrence data as it is incorporated into the NAS database. In May 2004, the NAS program developed an alert system to notify registered users of new introductions as part of a national early detection/rapid response system. This article summarizes information on system users and dispatched alerts from the system's inception through the end of 2011. The NAS alert system has registered over 1,700 users, with approximately 800 current subscribers. A total of 1,189 alerts had been transmitted through 2011. More alerts were sent for Florida (134 alerts) than for any other state. Fishes comprise the largest taxonomic group of alerts (440), with mollusks, plants, and crustaceans each containing over 100 alerts. Most alerts were for organisms that were intentionally released (414 alerts), with shipping, escape from captivity, and hitchhiking also representing major vectors. To explore the archive of sent alerts and to register, the search and signup page for the alert system can be found online at http://nas.er.usgs.gov/AlertSystem/default.aspx.
Acute effects of different light spectra on simulated night-shift work without circadian alignment.
Canazei, Markus; Pohl, Wilfried; Bliem, Harald R; Weiss, Elisabeth M
2017-01-01
Short-wavelength and short-wavelength-enhanced light have a strong impact on night-time working performance, subjective feelings of alertness and circadian physiology. In the present study, we investigated acute effects of white light sources with varied reduced portions of short wavelengths on cognitive and visual performance, mood and cardiac output.Thirty-one healthy subjects were investigated in a balanced cross-over design under three light spectra in a simulated night-shift paradigm without circadian adaptation.Exposure to the light spectrum with the largest attenuation of short wavelengths reduced heart rate and increased vagal cardiac parameters during the night compared to the other two light spectra without deleterious effects on sustained attention, working memory and subjective alertness. In addition, colour discrimination capability was significantly decreased under this light source.To our knowledge, the present study for the first time demonstrates that polychromatic white light with reduced short wavelengths, fulfilling current lighting standards for indoor illumination, may have a positive impact on cardiac physiology of night-shift workers without detrimental consequences for cognitive performance and alertness.
Testing new methodologies for short -term earthquake forecasting: Multi-parameters precursors
NASA Astrophysics Data System (ADS)
Ouzounov, Dimitar; Pulinets, Sergey; Tramutoli, Valerio; Lee, Lou; Liu, Tiger; Hattori, Katsumi; Kafatos, Menas
2014-05-01
We are conducting real-time tests involving multi-parameter observations over different seismo-tectonics regions in our investigation of phenomena preceding major earthquakes. Our approach is based on a systematic analysis of several selected parameters, namely: gas discharge; thermal infrared radiation; ionospheric electron density; and atmospheric temperature and humidity, which we believe are all associated with the earthquake preparation phase. We are testing a methodology capable to produce alerts in advance of major earthquakes (M > 5.5) in different regions of active earthquakes and volcanoes. During 2012-2013 we established a collaborative framework with PRE-EARTHQUAKE (EU) and iSTEP3 (Taiwan) projects for coordinated measurements and prospective validation over seven testing regions: Southern California (USA), Eastern Honshu (Japan), Italy, Greece, Turkey, Taiwan (ROC), Kamchatka and Sakhalin (Russia). The current experiment provided a "stress test" opportunity to validate the physical based earthquake precursor approach over regions of high seismicity. Our initial results are: (1) Real-time tests have shown the presence of anomalies in the atmosphere and ionosphere before most of the significant (M>5.5) earthquakes; (2) False positives exist and ratios are different for each region, varying between 50% for (Southern Italy), 35% (California) down to 25% (Taiwan, Kamchatka and Japan) with a significant reduction of false positives as soon as at least two geophysical parameters are contemporarily used; (3) Main problems remain related to the systematic collection and real-time integration of pre-earthquake observations. Our findings suggest that real-time testing of physically based pre-earthquake signals provides a short-term predictive power (in all three important parameters, namely location, time and magnitude) for the occurrence of major earthquakes in the tested regions and this result encourages testing to continue with a more detailed analysis of false alarm ratios and understanding of the overall physics of earthquake preparation.
Russ, Alissa L; Zillich, Alan J; Melton, Brittany L; Russell, Scott A; Chen, Siying; Spina, Jeffrey R; Weiner, Michael; Johnson, Elizabette G; Daggy, Joanne K; McManus, M Sue; Hawsey, Jason M; Puleo, Anthony G; Doebbeling, Bradley N; Saleem, Jason J
2014-01-01
Objective To apply human factors engineering principles to improve alert interface design. We hypothesized that incorporating human factors principles into alerts would improve usability, reduce workload for prescribers, and reduce prescribing errors. Materials and methods We performed a scenario-based simulation study using a counterbalanced, crossover design with 20 Veterans Affairs prescribers to compare original versus redesigned alerts. We redesigned drug–allergy, drug–drug interaction, and drug–disease alerts based upon human factors principles. We assessed usability (learnability of redesign, efficiency, satisfaction, and usability errors), perceived workload, and prescribing errors. Results Although prescribers received no training on the design changes, prescribers were able to resolve redesigned alerts more efficiently (median (IQR): 56 (47) s) compared to the original alerts (85 (71) s; p=0.015). In addition, prescribers rated redesigned alerts significantly higher than original alerts across several dimensions of satisfaction. Redesigned alerts led to a modest but significant reduction in workload (p=0.042) and significantly reduced the number of prescribing errors per prescriber (median (range): 2 (1–5) compared to original alerts: 4 (1–7); p=0.024). Discussion Aspects of the redesigned alerts that likely contributed to better prescribing include design modifications that reduced usability-related errors, providing clinical data closer to the point of decision, and displaying alert text in a tabular format. Displaying alert text in a tabular format may help prescribers extract information quickly and thereby increase responsiveness to alerts. Conclusions This simulation study provides evidence that applying human factors design principles to medication alerts can improve usability and prescribing outcomes. PMID:24668841
Russ, Alissa L; Zillich, Alan J; Melton, Brittany L; Russell, Scott A; Chen, Siying; Spina, Jeffrey R; Weiner, Michael; Johnson, Elizabette G; Daggy, Joanne K; McManus, M Sue; Hawsey, Jason M; Puleo, Anthony G; Doebbeling, Bradley N; Saleem, Jason J
2014-10-01
To apply human factors engineering principles to improve alert interface design. We hypothesized that incorporating human factors principles into alerts would improve usability, reduce workload for prescribers, and reduce prescribing errors. We performed a scenario-based simulation study using a counterbalanced, crossover design with 20 Veterans Affairs prescribers to compare original versus redesigned alerts. We redesigned drug-allergy, drug-drug interaction, and drug-disease alerts based upon human factors principles. We assessed usability (learnability of redesign, efficiency, satisfaction, and usability errors), perceived workload, and prescribing errors. Although prescribers received no training on the design changes, prescribers were able to resolve redesigned alerts more efficiently (median (IQR): 56 (47) s) compared to the original alerts (85 (71) s; p=0.015). In addition, prescribers rated redesigned alerts significantly higher than original alerts across several dimensions of satisfaction. Redesigned alerts led to a modest but significant reduction in workload (p=0.042) and significantly reduced the number of prescribing errors per prescriber (median (range): 2 (1-5) compared to original alerts: 4 (1-7); p=0.024). Aspects of the redesigned alerts that likely contributed to better prescribing include design modifications that reduced usability-related errors, providing clinical data closer to the point of decision, and displaying alert text in a tabular format. Displaying alert text in a tabular format may help prescribers extract information quickly and thereby increase responsiveness to alerts. This simulation study provides evidence that applying human factors design principles to medication alerts can improve usability and prescribing outcomes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Provider acceptance of an automated electronic alert for acute kidney injury
Oh, Janice; Bia, Joshua R.; Ubaid-Ullah, Muhamad; Testani, Jeffrey M.; Wilson, Francis Perry
2016-01-01
Background Clinical decision support systems, including electronic alerts, ideally provide immediate and relevant patient-specific information to improve clinical decision-making. Despite the growing capabilities of such alerts in conjunction with an expanding electronic medical record, there is a paucity of information regarding their perceived usefulness. We surveyed healthcare providers' opinions concerning the practicality and efficacy of a specific text-based automated electronic alert for acute kidney injury (AKI) in a single hospital during a randomized trial of AKI alerts. Methods Providers who had received at least one electronic AKI alert in the previous 6 months, as part of a separate randomized controlled trial (clinicaltrials.gov #01862419), were asked to complete a survey concerning their opinions about this specific AKI alert system. Individual approval of the alert system was defined by a provider's desire to continue receiving the alert after termination of the trial. Results A total of 98 individuals completed the survey, including 62 physicians, 27 pharmacists and 7 non-physician providers. Sixty-nine percent of responders approved the alert, with no significant difference among the various professions (P = 0.28). Alert approval was strongly correlated with the belief that the alerts improved patient care (P < 0.0001), and negatively correlated with the belief that alerts did not provide novel information (P = 0.0001). With each additional 30 days of trial duration, odds of approval decreased by 20% (3–35%) (P = 0.02). Conclusions The alert system was generally well received, although approval waned with time. Approval was correlated with the belief that this type of alert improved patient care. These findings suggest that perceived efficacy is critical to the success of future alert trials. PMID:27478598
Shah, Priya; Wyatt, Jeremy C; Makubate, Boikanyo; Cross, Frank W
2011-01-01
Objective Expert authorities recommend clinical decision support systems to reduce prescribing error rates, yet large numbers of insignificant on-screen alerts presented in modal dialog boxes persistently interrupt clinicians, limiting the effectiveness of these systems. This study compared the impact of modal and non-modal electronic (e-) prescribing alerts on prescribing error rates, to help inform the design of clinical decision support systems. Design A randomized study of 24 junior doctors each performing 30 simulated prescribing tasks in random order with a prototype e-prescribing system. Using a within-participant design, doctors were randomized to be shown one of three types of e-prescribing alert (modal, non-modal, no alert) during each prescribing task. Measurements The main outcome measure was prescribing error rate. Structured interviews were performed to elicit participants' preferences for the prescribing alerts and their views on clinical decision support systems. Results Participants exposed to modal alerts were 11.6 times less likely to make a prescribing error than those not shown an alert (OR 11.56, 95% CI 6.00 to 22.26). Those shown a non-modal alert were 3.2 times less likely to make a prescribing error (OR 3.18, 95% CI 1.91 to 5.30) than those not shown an alert. The error rate with non-modal alerts was 3.6 times higher than with modal alerts (95% CI 1.88 to 7.04). Conclusions Both kinds of e-prescribing alerts significantly reduced prescribing error rates, but modal alerts were over three times more effective than non-modal alerts. This study provides new evidence about the relative effects of modal and non-modal alerts on prescribing outcomes. PMID:21836158
Efferent-Mediated Responses in Vestibular Nerve Afferents of the Alert Macaque
Sadeghi, Soroush G.; Goldberg, Jay M.; Minor, Lloyd B.; Cullen, Kathleen E.
2009-01-01
The peripheral vestibular organs have long been known to receive a bilateral efferent innervation from the brain stem. However, the functional role of the efferent vestibular system has remained elusive. In this study, we investigated efferent-mediated responses in vestibular afferents of alert behaving primates (macaque monkey). We found that efferent-mediated rotational responses could be obtained from vestibular nerve fibers innervating the semicircular canals after conventional afferent responses were nulled by placing the corresponding canal plane orthogonal to the plane of motion. Responses were type III, i.e., excitatory for rotational velocity trapezoids (peak velocity, 320°/s) in both directions of rotation, consistent with those previously reported in the decerebrate chinchilla. Responses consisted of both fast and slow components and were larger in irregular (∼10 spikes/s) than in regular afferents (∼2 spikes/s). Following unilateral labyrinthectomy (UL) on the side opposite the recording site, similar responses were obtained. To confirm the vestibular source of the efferent-mediated responses, the ipsilateral horizontal and posterior canals were plugged following the UL. Responses to high-velocity rotations were drastically reduced when the superior canal (SC), the only intact canal, was in its null position, compared with when the SC was pitched 50° upward from the null position. Our findings show that vestibular afferents in alert primates show efferent-mediated responses that are related to the discharge regularity of the afferent, are of vestibular origin, and can be the result of both afferent excitation and inhibition. PMID:19091917
Efferent-mediated responses in vestibular nerve afferents of the alert macaque.
Sadeghi, Soroush G; Goldberg, Jay M; Minor, Lloyd B; Cullen, Kathleen E
2009-02-01
The peripheral vestibular organs have long been known to receive a bilateral efferent innervation from the brain stem. However, the functional role of the efferent vestibular system has remained elusive. In this study, we investigated efferent-mediated responses in vestibular afferents of alert behaving primates (macaque monkey). We found that efferent-mediated rotational responses could be obtained from vestibular nerve fibers innervating the semicircular canals after conventional afferent responses were nulled by placing the corresponding canal plane orthogonal to the plane of motion. Responses were type III, i.e., excitatory for rotational velocity trapezoids (peak velocity, 320 degrees/s) in both directions of rotation, consistent with those previously reported in the decerebrate chinchilla. Responses consisted of both fast and slow components and were larger in irregular (approximately 10 spikes/s) than in regular afferents (approximately 2 spikes/s). Following unilateral labyrinthectomy (UL) on the side opposite the recording site, similar responses were obtained. To confirm the vestibular source of the efferent-mediated responses, the ipsilateral horizontal and posterior canals were plugged following the UL. Responses to high-velocity rotations were drastically reduced when the superior canal (SC), the only intact canal, was in its null position, compared with when the SC was pitched 50 degrees upward from the null position. Our findings show that vestibular afferents in alert primates show efferent-mediated responses that are related to the discharge regularity of the afferent, are of vestibular origin, and can be the result of both afferent excitation and inhibition.
Acquisition and use of Orlando, Florida and Continental Airbus radar flight test data
NASA Technical Reports Server (NTRS)
Eide, Michael C.; Mathews, Bruce
1992-01-01
Westinghouse is developing a lookdown pulse Doppler radar for production as the sensor and processor of a forward looking hazardous windshear detection and avoidance system. A data collection prototype of that product was ready for flight testing in Orlando to encounter low level windshear in corroboration with the FAA-Terminal Doppler Weather Radar (TDWR). Airborne real-time processing and display of the hazard factor were demonstrated with TDWR facilitated intercepts and penetrations of over 80 microbursts in a three day period, including microbursts with hazard factors in excess of .16 (with 500 ft. PIREP altitude loss) and the hazard factor display at 6 n.mi. of a visually transparent ('dry') microburst with TDWR corroborated outflow reflectivities of +5 dBz. Range gated Doppler spectrum data was recorded for subsequent development and refinement of hazard factor detection and urban clutter rejection algorithms. Following Orlando, the data collection radar was supplemental type certified for in revenue service on a Continental Airlines Airbus in an automatic and non-interferring basis with its ARINC 708 radar to allow Westinghouse to confirm its understanding of commercial aircraft installation, interface realities, and urban airport clutter. A number of software upgrades, all of which were verified at the Receiver-Transmitter-Processor (RTP) hardware bench with Orlando microburst data to produce desired advanced warning hazard factor detection, included some preliminary loads with automatic (sliding window average hazard factor) detection and annunciation recording. The current (14-APR-92) configured software is free from false and/or nuisance alerts (CAUTIONS, WARNINGS, etc.) for all take-off and landing approaches, under 2500 ft. altitude to weight-on-wheels, into all encountered airports, including Newark (NJ), LAX, Denver, Houston, Cleveland, etc. Using the Orlando data collected on hazardous microbursts, Westinghouse has developed a lookdown pulse Doppler radar product with signal and data processing algorithms which detect realistic microburst hazards and has demonstrated those algorithms produce no false alerts (or nuisance alerts) in urban airport ground moving vehicle (GMTI) and/or clutter environments.
Living with the AIDS Virus: A Representative Case.
ERIC Educational Resources Information Center
Gordon, Jennifer; Shontz, Franklin C.
1990-01-01
Uses human sciences, multilevel, hermeneutic approach to study life experiences of 21-year-old male who had tested positive for Acquired Immunodeficiency Syndrome virus but who was asymptomatic. Demonstrates uses of systematic, personological procedure for examining these experiences and alerts practitioners to central psychological themes that…
Provider management strategies of abnormal test result alerts: a cognitive task analysis
Sawhney, Mona K; Wilson, Lindsay; Sittig, Dean F; Espadas, Donna; Davis, Traber; Singh, Hardeep
2010-01-01
Objective Electronic medical records (EMRs) facilitate abnormal test result communication through “alert” notifications. The aim was to evaluate how primary care providers (PCPs) manage alerts related to critical diagnostic test results on their EMR screens, and compare alert-management strategies of providers with high versus low rates of timely follow-up of results. Design 28 PCPs from a large, tertiary care Veterans Affairs Medical Center (VAMC) were purposively sampled according to their rates of timely follow-up of alerts, determined in a previous study. Using techniques from cognitive task analysis, participants were interviewed about how and when they manage alerts, focusing on four alert-management features to filter, sort and reduce unnecessary alerts on their EMR screens. Results Provider knowledge of alert-management features ranged between 4% and 75%. Almost half (46%) of providers did not use any of these features, and none used more than two. Providers with higher versus lower rates of timely follow-up used the four features similarly, except one (customizing alert notifications). Providers with low rates of timely follow-up tended to manually scan the alert list and process alerts heuristically using their clinical judgment. Additionally, 46% of providers used at least one workaround strategy to manage alerts. Conclusion Considerable heterogeneity exists in provider use of alert-management strategies; specific strategies may be associated with lower rates of timely follow-up. Standardization of alert-management strategies including improving provider knowledge of appropriate tools in the EMR to manage alerts could reduce the lack of timely follow-up of abnormal diagnostic test results. PMID:20064805
Reducing duplicate testing: a comparison of two clinical decision support tools.
Procop, Gary W; Keating, Catherine; Stagno, Paul; Kottke-Marchant, Kandice; Partin, Mary; Tuttle, Robert; Wyllie, Robert
2015-05-01
Unnecessary duplicate laboratory testing is common and costly. Systems-based means to avert unnecessary testing should be investigated and employed. We compared the effectiveness and cost savings associated with two clinical decision support tools to stop duplicate testing. The Hard Stop required telephone contact with the laboratory and justification to have the duplicate test performed, whereas the Smart Alert allowed the provider to bypass the alert at the point of order entry without justification. The Hard Stop alert was significantly more effective than the Smart Alert (92.3% vs 42.6%, respectively; P < .0001). The cost savings realized per alert activation was $16.08/alert for the Hard Stop alert vs $3.52/alert for the Smart Alert. Structural and process changes that require laboratory contact and justification for duplicate testing are more effective than interventions that allow providers to bypass alerts without justification at point of computerized physician order entry. Copyright© by the American Society for Clinical Pathology.
Kids Get a Positive Lesson from this Discipline Program.
ERIC Educational Resources Information Center
Shropshire, John
1982-01-01
Sequoia Freshman School, a ninth-grade school in Fresno (California), has drastically reduced suspensions through a noontime in-school suspension program that helps students recognize inappropriate behavior, gives them counseling, and alerts parents or guardians to student misbehavior. A copy of the notification form is included. (Author/RW)
Effects of Pet and/or People Visits on Nursing Home.
ERIC Educational Resources Information Center
Hendy, Helen M.
1987-01-01
Compared effects of different visiting programs (people, people and pets, pets, no visit) on behaviors of nursing home residents. Found all three visiting programs increased behaviors of smiling and alertness in comparison to control conditions. Close proximity to person-alone visitor was associated with greatest number of positive resident…
Commercial Mobile Alert Service (CMAS) Alerting Pipeline Taxonomy
2012-03-01
for the consumer at the mo- ment but will soon become a commoditized, basic requirement. For example, as the baby boomers grow older, mobile services...Commercial Mobile Alert Service (CMAS) Alerting Pipeline Taxonomy The WEA Project Team March 2012 SPECIAL REPORT CMU/SEI-2012-TR-019 CERT...report presents a taxonomy developed for the Commercial Mobile Alert Service (CMAS). The CMAS Alerting Pipeline Taxonomy is a hierarchical classification
Wireless Emergency Alerts (WEA) Cybersecurity Risk Management Strategy for Alert Originators
2014-03-01
formerly known as the Commercial Mobile Alert Service ( CMAS ) RDT&E program, is a collaborative partnership that includes the cellular industry, the...Examples illustrate a STRIDE analysis of the generic mission 1 The CMAS Alerting Pipeline Taxonomy describes in detail a hierarchical classification...SEI-2013-SR-018 | 1 1 Introduction The Wireless Emergency Alerts (WEA) service, formerly known as the Commercial Mobile Alert Service ( CMAS ), is a
A Novel Design for Drug-Drug Interaction Alerts Improves Prescribing Efficiency.
Russ, Alissa L; Chen, Siying; Melton, Brittany L; Johnson, Elizabette G; Spina, Jeffrey R; Weiner, Michael; Zillich, Alan J
2015-09-01
Drug-drug interactions (DDIs) are common in clinical care and pose serious risks for patients. Electronic health records display DDI alerts that can influence prescribers, but the interface design of DDI alerts has largely been unstudied. In this study, the objective was to apply human factors engineering principles to alert design. It was hypothesized that redesigned DDI alerts would significantly improve prescribers' efficiency and reduce prescribing errors. In a counterbalanced, crossover study with prescribers, two DDI alert designs were evaluated. Department of Veterans Affairs (VA) prescribers were video recorded as they completed fictitious patient scenarios, which included DDI alerts of varying severity. Efficiency was measured from time-stamped recordings. Prescribing errors were evaluated against predefined criteria. Efficiency and prescribing errors were analyzed with the Wilcoxon signed-rank test. Other usability data were collected on the adequacy of alert content, prescribers' use of the DDI monograph, and alert navigation. Twenty prescribers completed patient scenarios for both designs. Prescribers resolved redesigned alerts in about half the time (redesign: 52 seconds versus original design: 97 seconds; p<.001). Prescribing errors were not significantly different between the two designs. Usability results indicate that DDI alerts might be enhanced by facilitating easier access to laboratory data and dosing information and by allowing prescribers to cancel either interacting medication directly from the alert. Results also suggest that neither design provided adequate information for decision making via the primary interface. Applying human factors principles to DDI alerts improved overall efficiency. Aspects of DDI alert design that could be further enhanced prior to implementation were also identified.
76 FR 80780 - Review of the Emergency Alert System
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-27
... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: In this document, the Commission amends its rules governing the Emergency Alert System (EAS) rules to extend the deadline for EAS Participants to be able to receive Common Alerting Protocol (CAP)- formatted EAS alerts to...
NASA Astrophysics Data System (ADS)
Applbaum, David; Dorman, Lev; Pustil'Nik, Lev; Sternlieb, Abraham; Zagnetko, Alexander; Zukerman, Igor
It is well known that during great SEP events, fluxes of energetic particles can be so big that the memory of computers and other electronics in space may be destroyed, and satellites and spacecraft may cease to function. According to the NOAA Space Weather Prediction Cen-ter, the following scales constitute dangerous solar radiation storms: S5-extreme (flux level of particles with energy ∼ 10 MeV more than 105 ); S4 - severe(f luxmorethan104 ); andS3 - strong(f luxmorethan103 ). In these persiods, it is necessary to switch off some of the electronics for a few hours energy particles (meaning those with a few GeV/nucleon and higher), whose transportation to Earthfrom the S20 minutes after they accelerate and escape into the solar wind) than the main bulk of the smaller energy particle 60 minutes later). Here we describe the principles and experience of the automatic function of the "SEP - Search" program. The positive result, showing the exact beginning of an SEP event on the Emilio Segre Observ 10.8GV ), is determined now automatically by simultaneously increasing by 2.5 St.Dev. in two sections of the ne search "programnext uses 1-mindata for checking whether or not the observed increase reflects the beginning Research "automatically starts to work online. We determine also the probabilities of false and missed alerts.
Chen, J Y C; Terrence, P I
2009-08-01
This study investigated the performance and workload of the combined position of gunner and robotics operator in a simulated military multitasking environment. Specifically, the study investigated how aided target recognition (AiTR) capabilities for the gunnery task with imperfect reliability (false-alarm-prone vs. miss-prone) might affect the concurrent robotics and communication tasks. Additionally, the study examined whether performance was affected by individual differences in spatial ability and attentional control. Results showed that when the robotics task was simply monitoring the video, participants had the best performance in their gunnery and communication tasks and the lowest perceived workload, compared with the other robotics tasking conditions. There was a strong interaction between the type of AiTR unreliability and participants' perceived attentional control. Overall, for participants with higher perceived attentional control, false-alarm-prone alerts were more detrimental; for low attentional control participants, conversely, miss-prone automation was more harmful. Low spatial ability participants preferred visual cueing and high spatial ability participants favoured tactile cueing. Potential applications of the findings include personnel selection for robotics operation, robotics user interface designs and training development. The present results will provide further understanding of the interplays among automation reliability, multitasking performance and individual differences in military tasking environments. These results will also facilitate the implementation of robots in military settings and will provide useful data to military system designs.
Application of neuro-fuzzy methods to gamma spectroscopy
NASA Astrophysics Data System (ADS)
Grelle, Austin L.
Nuclear non-proliferation activities are an essential part of national security activities both domestic and abroad. The safety of the public in densely populated environments such as urban areas or large events can be compromised if devices using special nuclear materials are present. Therefore, the prompt and accurate detection of these materials is an important topic of research, in which the identification of normal conditions is also of importance. With gamma-ray spectroscopy, these conditions are identified as the radiation background, which though being affected by a multitude of factors is ever present. Therefore, in nuclear non-proliferation activities the accurate identification of background is important. With this in mind, a method has been developed to utilize aggregate background data to predict the background of a location through the use of an Artificial Neural Network (ANN). After being trained on background data, the ANN is presented with nearby relevant gamma-ray spectroscopy data---as identified by a Fuzzy Inference System - to create a predicted background spectra to compare to a measured spectra. If a significant deviation exists between the predicted and measured data, the method alerts the user such that a more thorough investigation can take place. Research herein focused on data from an urban setting in which the number of false positives was observed to be 28 out of a total of 987, representing 2.94% error. The method therefore currently shows a high rate of false positives given the current configuration, however there are promising steps that can be taken to further minimize this error. With this in mind, the method stands as a potentially significant tool in urban nuclear nonproliferation activities.
& Imagery; includes NWS alerts and warnings No 6 Wireless Emergency Alerts (WEA) Mobile Phone Alerts & Warnings only No 7 Interactive NWS (iNWS) - NOTE 1 https://inws.ncep.noaa.gov/ Mobile Phone $$$$) Internet/ Mobile Phone Alerts and Warnings No 15 County or Local Emergency Management Telephone alert
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-11
... Special Fraud Alert on Telemarketing by Durable Medical Equipment Suppliers AGENCY: Office of Inspector... Special Fraud Alert. Specifically, the Updated Special Fraud Alert addressed the statutory provision...) 205-0007. SUPPLEMENTARY INFORMATION: In our publication of the OIG Updated Special Fraud Alert on...
Nishimura, Adam A.; Shirts, Brian H.; Salama, Joseph; Smith, Joe W.; Devine, Beth; Tarczy-Hornoch, Peter
2015-01-01
Objective To determine if physicians find clinical decision support alerts for pharmacogenomic drug-gene interactions useful and assess their perceptions of usability aspects that impact usefulness. Materials and Methods 52 physicians participated in an online simulation and questionnaire involving a prototype alert for the clopidogrel and CYP2C19 drug-gene interaction. Results Only 4% of participants stated they would override the alert. 92% agreed that the alerts were useful. 87% found the visual interface appropriate, 91% felt the timing of the alert was appropriate and 75% were unfamiliar with the specific drug-gene interaction. 80% of providers preferred the ability to order the recommended medication within the alert. Qualitative responses suggested that supplementary information is important, but should be provided as external links, and that the utility of pharmacogenomic alerts depends on the broader ecosystem of alerts. Principal Conclusions Pharmacogenomic alerts would be welcomed by many physicians, can be built with minimalist design principles, and are appropriately placed at the end of the prescribing process. Since many physicians lack familiarity with pharmacogenomics but have limited time, information and educational resources within the alert should be carefully selected and presented in concise ways. PMID:26642939
Nishimura, Adam A; Shirts, Brian H; Salama, Joseph; Smith, Joe W; Devine, Beth; Tarczy-Hornoch, Peter
2016-02-01
To determine if physicians find clinical decision support alerts for pharmacogenomic drug-gene interactions useful and assess their perceptions of usability aspects that impact usefulness. 52 physicians participated in an online simulation and questionnaire involving a prototype alert for the clopidogrel and CYP2C19 drug-gene interaction. Only 4% of participants stated they would override the alert. 92% agreed that the alerts were useful. 87% found the visual interface appropriate, 91% felt the timing of the alert was appropriate and 75% were unfamiliar with the specific drug-gene interaction. 80% of providers preferred the ability to order the recommended medication within the alert. Qualitative responses suggested that supplementary information is important, but should be provided as external links, and that the utility of pharmacogenomic alerts depends on the broader ecosystem of alerts. Pharmacogenomic alerts would be welcomed by many physicians, can be built with minimalist design principles, and are appropriately placed at the end of the prescribing process. Since many physicians lack familiarity with pharmacogenomics but have limited time, information and educational resources within the alert should be carefully selected and presented in concise ways. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Cutrona, Sarah L; Fouayzi, Hassan; Burns, Laura; Sadasivam, Rajani S; Mazor, Kathleen M; Gurwitz, Jerry H; Garber, Lawrence; Sundaresan, Devi; Houston, Thomas K; Field, Terry S
2017-11-01
Time-sensitive alerts are among the many types of clinical notifications delivered to physicians' secure InBaskets within commercial electronic health records (EHRs). A delayed alert review can impact patient safety and compromise care. To characterize factors associated with opening of non-interruptive time-sensitive alerts delivered into primary care provider (PCP) InBaskets. We analyzed data for 799 automated alerts. Alerts highlighted actionable medication concerns for older patients post-hospital discharge (2010-2011). These were study-generated alerts sent 3 days post-discharge to InBaskets for 75 PCPs across a multisite healthcare system, and represent a subset of all urgent InBasket notifications. Using EHR access and audit logs to track alert opening, we performed bivariate and multivariate analyses calculating associations between patient characteristics, provider characteristics, contextual factors at the time of alert delivery (number of InBasket notifications, weekday), and alert opening within 24 h. At the time of alert delivery, the PCPs had a median of 69 InBasket notifications and had received a median of 379.8 notifications (IQR 295.0, 492.0) over the prior 7 days. Of the 799 alerts, 47.1% were opened within 24 h. Patients with longer hospital stays (>4 days) were marginally more likely to have alerts opened (OR 1.48 [95% CI 1.00-2.19]). Alerts delivered to PCPs whose InBaskets had a higher number of notifications at the time of alert delivery were significantly less likely to be opened within 24 h (top quartile >157 notifications: OR 0.34 [95% CI 0.18-0.61]; reference bottom quartile ≤42). Alerts delivered on Saturdays were also less likely to be opened within 24 h (OR 0.18 [CI 0.08-0.39]). The number of total InBasket notifications and weekend delivery may impact the opening of time-sensitive EHR alerts. Further study is needed to support safe and effective approaches to care team management of InBasket notifications.
Pilot evaluation of a method to assess prescribers' information processing of medication alerts.
Russ, Alissa L; Melton, Brittany L; Daggy, Joanne K; Saleem, Jason J
2017-02-01
Prescribers commonly receive alerts during medication ordering. Prescribers work in a complex, time-pressured environment; to enhance the effectiveness of safety alerts, the effort needed to cognitively process these alerts should be minimized. Methods to evaluate the extent to which computerized alerts support prescribers' information processing are lacking. To develop a methodological protocol to assess the extent to which alerts support prescribers' information processing at-a-glance; specifically, the incorporation of information into their working memory. We hypothesized that the method would be feasible and that we would be able to detect a significant difference in prescribers' information processing with a revised alert display that incorporates warning design guidelines compared to the original alert display. A counterbalanced, within-subject study was conducted with 20 prescribers in a human-computer interaction laboratory. We tested a single alert that was displayed in two different ways. Prescribers were informed that an alert would appear for 10s. After the alert was shown, a white screen was displayed, and prescribers were asked to verbally describe what they saw; indicate how many total warnings; and describe anything else they remembered about the alert. We measured information processing via the accuracy of prescribers' free recall and their ability to identify that three warning messages were present. Two analysts independently evaluated participants' responses against a comprehensive catalog of alert elements and then discussed discrepancies until reaching consensus. This feasibility study demonstrated that the method seemed to be effective for evaluating prescribers' information processing of medication alert displays. With this method, we were able to detect significant differences in prescribers' recall of alert information. The proportion of total data elements that prescribers were able to accurately recall was significantly greater for the revised versus original alert display (p=0.006). With the revised display, more prescribers accurately reported that three warnings were shown (p=0.002). The methodological protocol was feasible for evaluating the alert display and yielded important findings on prescribers' information processing. Study methods supplement traditional usability evaluation methods and may be useful for evaluating information processing of other healthcare technologies. Published by Elsevier Inc.
Intraoperative neurophysiological monitoring team's communiqué with anesthesia professionals.
Tewari, Anurag; Francis, Lisa; Samy, Ravi N; Kurth, Dean C; Castle, Joshua; Frye, Tiffany; Mahmoud, Mohamed
2018-01-01
Intraoperative neurophysiological monitoring (IONM) is the standard of care during many spinal, vascular, and intracranial surgeries. High-quality perioperative care requires the communication and cooperation of several multidisciplinary teams. One of these multidisciplinary services is intraoperative neuromonitoring (IONM), while other teams represent anesthesia and surgery. Few studies have investigated the IONM team's objective communication with anesthesia providers. We conducted a retrospective review of IONM-related quality assurance data to identify how changes in the evoked potentials observed during the surgery were communicated within our IONM-anesthesia team and determined the resulting qualitative outcomes. Quality assurance records of 3,112 patients who underwent surgical procedures with IONM (from 2010 to 2015) were reviewed. We examined communications regarding perioperative evoked potential or electroencephalography (EEG) fluctuations that prompted neurophysiologists to alert/notify the anesthesia team to consider alteration of anesthetic depth/drug regimen or patient positioning and analyzed the outcomes of these interventions. Of the total of 1280 (41.13%) communications issued, there were 347 notifications and 11 alerts made by the neurophysiologist to the anesthesia team for various types of neuro/orthopedic surgeries. Prompt communication led to resolution of 90% of alerts and 80% of notifications after corrective measures were executed by the anesthesiologists. Notifications mainly related to limb malpositioning and extravasation of intravenous fluid. Based on our institutions' protocol and algorithm for intervention during IONM-supported surgeries, our findings of resolution in alerts and notifications indicate that successful communications between the two teams could potentially lead to improved anesthetic care and patient safety.
Beuhler, Michael C; Wittler, Mary A; Ford, Marsha; Dulaney, Anna R
2011-08-01
Many public health entities employ computer-based syndromic surveillance to monitor for aberrations including possible exposures to weapons of mass destruction (WMD). Often, this is done by screening signs and symptoms reported for cases against syndromic definitions. Poison centers (PCs) may offer significant contributions to public health surveillance because of their detailed clinical effect data field coding and real-time data entry. Because improper clinical effect coding may impede syndromic surveillance, it is important to assess this accuracy for PCs. An AAPCC-certified regional PC assessed the accuracy of clinical effect coding by specialists in poison information (SPIs) listening to audio recordings of standard cases. Eighteen different standardized cases were used, consisting of six cyanide, six botulism, and six control cases. Cases were scripted to simulate clinically relevant telephone conversations and converted to audio recordings. Ten SPIs were randomly selected from the center's staff to listen to and code case information from the recorded cases. Kappa scores and the percentage of correctly coding a present clinical effect were calculated for individual clinical effects summed over all test cases along with corresponding 95% confidence intervals. The rate of the case coding by the SPIs triggering the PC's automated botulism and cyanide alerts was also determined. The kappa scores and the percentage of correctly coding a present clinical effect varied depending on the specific clinical effect, with greater accuracy observed for the clinical effects of vomiting and agitation/irritability, and poor accuracy observed for the clinical effects of visual defect and anion gap increase. Lack of correct coding resulted in only 60 and 86% of the cases that met the botulism and cyanide surveillance definitions, respectively, triggering the corresponding alert. There was no difference observed in the percentage of coding a present clinical effect between certified (9.0 years experience) and non-certified (2.4 years experience) specialists. There were no cases of coding errors that resulted in the triggering of a false positive alert. The success of syndromic surveillance depends on accurate coding of signs and symptoms. Although PCs generally contribute high-quality data to public health surveillance, it is important to recognize this potential weak link in surveillance methods.
Balasuriya, Lilanthi; Vyles, David; Bakerman, Paul; Holton, Vanessa; Vaidya, Vinay; Garcia-Filion, Pamela; Westdorp, Joan; Sanchez, Christine; Kurz, Rhonda
2017-09-01
An enhanced dose range checking (DRC) system was developed to evaluate prescription error rates in the pediatric intensive care unit and the pediatric cardiovascular intensive care unit. An enhanced DRC system incorporating "soft" and "hard" alerts was designed and implemented. Practitioner responses to alerts for patients admitted to the pediatric intensive care unit and the pediatric cardiovascular intensive care unit were retrospectively reviewed. Alert rates increased from 0.3% to 3.4% after "go-live" (P < 0.001). Before go-live, all alerts were soft alerts. In the period after go-live, 68% of alerts were soft alerts and 32% were hard alerts. Before go-live, providers reduced doses only 1 time for every 10 dose alerts. After implementation of the enhanced computerized physician order entry system, the practitioners responded to soft alerts by reducing doses to more appropriate levels in 24.7% of orders (70/283), compared with 10% (3/30) before go-live (P = 0.0701). The practitioners deleted orders in 9.5% of cases (27/283) after implementation of the enhanced DRC system, as compared with no cancelled orders before go-live (P = 0.0774). Medication orders that triggered a soft alert were submitted unmodified in 65.7% (186/283) as compared with 90% (27/30) of orders before go-live (P = 0.0067). After go-live, 28.7% of hard alerts resulted in a reduced dose, 64% resulted in a cancelled order, and 7.4% were submitted as written. Before go-live, alerts were often clinically irrelevant. After go-live, there was a statistically significant decrease in orders that were submitted unmodified and an increase in the number of orders that were reduced or cancelled.
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
Kuperman, G. J.; Teich, J. M.; Bates, D. W.; Hiltz, F. L.; Hurley, J. M.; Lee, R. Y.; Paterno, M. D.
1996-01-01
We developed and evaluated a system to automatically identify serious clinical conditions in inpatients. The system notifies the patient's covering physician via his pager that an alert is present and offers potential therapies for the patient's condition (action items) at the time he views the alert information. Over a 6 month period, physicians responded to 1214 (70.2%) of 1730 alerts for which they were paged; they responded to 1002 (82.5% of the 1214) in less than 15 minutes. They said they would take action in 71.5% of the alerts, and they placed an order directly from the alert display screen in 39.4%. Further study is needed to determine if this alerting system improves processes or outcomes of care. PMID:8947756
Clemens, Benjamin; Zvyagintsev, Mikhail; Sack, Alexander T; Sack, Alexander; Heinecke, Armin; Willmes, Klaus; Sturm, Walter
2011-01-01
Clinical observations and neuroimaging data revealed a right-hemisphere fronto-parietal-thalamic-brainstem network for intrinsic alertness, and additional left fronto-parietal activity during phasic alertness. The primary objective of this fMRI study was to map the functional neuroanatomy of intrinsic alertness as precisely as possible in healthy participants, using a novel assessment paradigm already employed in clinical settings. Both the paradigm and the experimental design were optimized to specifically assess intrinsic alertness, while at the same time controlling for sensory-motor processing. The present results suggest that the processing of intrinsic alertness is accompanied by increased activity within the brainstem, thalamus, anterior cingulate gyrus, right insula, and right parietal cortex. Additionally, we found increased activation in the left hemisphere around the middle frontal gyrus (BA 9), the insula, the supplementary motor area, and the cerebellum. Our results further suggest that rather minute aspects of the experimental design may induce aspects of phasic alertness, which in turn might lead to additional brain activation in left-frontal areas not normally involved in intrinsic alertness. Accordingly, left BA 9 activation may be related to co-activation of the phasic alertness network due to the switch between rest and task conditions functioning as an external warning cue triggering the phasic alertness network. Furthermore, activation of the intrinsic alertness network during fixation blocks due to enhanced expectancy shortly before the switch to the task block might, when subtracted from the task block, lead to diminished activation in the typical right hemisphere intrinsic alertness network. Thus, we cautiously suggest that--as a methodological artifact--left frontal activations might show up due to phasic alertness involvement and intrinsic alertness activations might be weakened due to contrasting with fixation blocks, when assessing the functional neuroanatomy of intrinsic alertness with a block design in fMRI studies.
Clemens, Benjamin; Zvyagintsev, Mikhail; Sack, Alexander; Heinecke, Armin; Willmes, Klaus; Sturm, Walter
2011-01-01
Clinical observations and neuroimaging data revealed a right-hemisphere fronto-parietal-thalamic-brainstem network for intrinsic alertness, and additional left fronto-parietal activity during phasic alertness. The primary objective of this fMRI study was to map the functional neuroanatomy of intrinsic alertness as precisely as possible in healthy participants, using a novel assessment paradigm already employed in clinical settings. Both the paradigm and the experimental design were optimized to specifically assess intrinsic alertness, while at the same time controlling for sensory-motor processing. The present results suggest that the processing of intrinsic alertness is accompanied by increased activity within the brainstem, thalamus, anterior cingulate gyrus, right insula, and right parietal cortex. Additionally, we found increased activation in the left hemisphere around the middle frontal gyrus (BA 9), the insula, the supplementary motor area, and the cerebellum. Our results further suggest that rather minute aspects of the experimental design may induce aspects of phasic alertness, which in turn might lead to additional brain activation in left-frontal areas not normally involved in intrinsic alertness. Accordingly, left BA 9 activation may be related to co-activation of the phasic alertness network due to the switch between rest and task conditions functioning as an external warning cue triggering the phasic alertness network. Furthermore, activation of the intrinsic alertness network during fixation blocks due to enhanced expectancy shortly before the switch to the task block might, when subtracted from the task block, lead to diminished activation in the typical right hemisphere intrinsic alertness network. Thus, we cautiously suggest that – as a methodological artifact – left frontal activations might show up due to phasic alertness involvement and intrinsic alertness activations might be weakened due to contrasting with fixation blocks, when assessing the functional neuroanatomy of intrinsic alertness with a block design in fMRI studies. PMID:21984928
Sushko, Iurii; Salmina, Elena; Potemkin, Vladimir A; Poda, Gennadiy; Tetko, Igor V
2012-08-27
The article presents a Web-based platform for collecting and storing toxicological structural alerts from literature and for virtual screening of chemical libraries to flag potentially toxic chemicals and compounds that can cause adverse side effects. An alert is uniquely identified by a SMARTS template, a toxicological endpoint, and a publication where the alert was described. Additionally, the system allows storing complementary information such as name, comments, and mechanism of action, as well as other data. Most importantly, the platform can be easily used for fast virtual screening of large chemical datasets, focused libraries, or newly designed compounds against the toxicological alerts, providing a detailed profile of the chemicals grouped by structural alerts and endpoints. Such a facility can be used for decision making regarding whether a compound should be tested experimentally, validated with available QSAR models, or eliminated from consideration altogether. The alert-based screening can also be helpful for an easier interpretation of more complex QSAR models. The system is publicly accessible and tightly integrated with the Online Chemical Modeling Environment (OCHEM, http://ochem.eu). The system is open and expandable: any registered OCHEM user can introduce new alerts, browse, edit alerts introduced by other users, and virtually screen his/her data sets against all or selected alerts. The user sets being passed through the structural alerts can be used at OCHEM for other typical tasks: exporting in a wide variety of formats, development of QSAR models, additional filtering by other criteria, etc. The database already contains almost 600 structural alerts for such endpoints as mutagenicity, carcinogenicity, skin sensitization, compounds that undergo metabolic activation, and compounds that form reactive metabolites and, thus, can cause adverse reactions. The ToxAlerts platform is accessible on the Web at http://ochem.eu/alerts, and it is constantly growing.
2012-01-01
The article presents a Web-based platform for collecting and storing toxicological structural alerts from literature and for virtual screening of chemical libraries to flag potentially toxic chemicals and compounds that can cause adverse side effects. An alert is uniquely identified by a SMARTS template, a toxicological endpoint, and a publication where the alert was described. Additionally, the system allows storing complementary information such as name, comments, and mechanism of action, as well as other data. Most importantly, the platform can be easily used for fast virtual screening of large chemical datasets, focused libraries, or newly designed compounds against the toxicological alerts, providing a detailed profile of the chemicals grouped by structural alerts and endpoints. Such a facility can be used for decision making regarding whether a compound should be tested experimentally, validated with available QSAR models, or eliminated from consideration altogether. The alert-based screening can also be helpful for an easier interpretation of more complex QSAR models. The system is publicly accessible and tightly integrated with the Online Chemical Modeling Environment (OCHEM, http://ochem.eu). The system is open and expandable: any registered OCHEM user can introduce new alerts, browse, edit alerts introduced by other users, and virtually screen his/her data sets against all or selected alerts. The user sets being passed through the structural alerts can be used at OCHEM for other typical tasks: exporting in a wide variety of formats, development of QSAR models, additional filtering by other criteria, etc. The database already contains almost 600 structural alerts for such endpoints as mutagenicity, carcinogenicity, skin sensitization, compounds that undergo metabolic activation, and compounds that form reactive metabolites and, thus, can cause adverse reactions. The ToxAlerts platform is accessible on the Web at http://ochem.eu/alerts, and it is constantly growing. PMID:22876798
Alert status of nuclear weapons
NASA Astrophysics Data System (ADS)
Kristensen, Hans M.
2017-11-01
Nuclear Alert Forces. Four nuclear-armed states deploy nuclear warheads on alert, ready to be used on relatively short notice: United States, Russia, France and Britain. Combined, the four countries deploy an estimated 1,869 nuclear alert warheads. Russia and the United States deploy 1,749 alert warheads combined, or 94% of all alert warheads. Despite some debate about possible need to increase readiness of nuclear forces (China, Pakistan), the five other nuclear-armed states (China, Pakistan, India, Israel and North Korea) are thought to store their warheads separate from launchers under normal circumstances. The overall number of alert warheads has remained relatively stable during the past five years.
Geo-targeted Weather Alerts Coming to Millions of Mobile Devices
NASA Astrophysics Data System (ADS)
Gerber, M.
2011-12-01
The Personal Localized Alert Network (PLAN), aka Commercial Mobile Alert System (CMAS), is readying for roll out and will be broadcasting emergency public alerts to millions of cell phones by the middle of 2012. Learn how the National Weather Serivce (NWS) is supplying PLAN with geo-referenced weather alert information in the industry standard Common Alerting Protocol (CAP) format and how you can access this same information for integration with mobile devices, other consumer electronics, and decision support systems. Information will also be provided on the NWS' new collaborative venue that encourages wide participation in the evolution and use of NWS CAP alerts in a variety of applications.
Automated External Defibrillator
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
Thrombocythemia and Thrombocytosis
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
Percutaneous Coronary Intervention
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
Thrombotic Thrombocytopenic Purpura
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
Regulatory alerts for dietary supplements in Canada and the United States, 2005-13.
Abe, Andrew M; Hein, Darren J; Gregory, Philip J
2015-06-01
Dietary supplement regulatory alerts published by the Food and Drug Administration (FDA) and Health Canada were evaluated and characterized. FDA MedWatch and Health Canada websites were reviewed to identify regulatory alerts regarding dietary supplements from January 1, 2005, through December 31, 2013. Alerts were analyzed to identify product characteristics that may be predictive of product quality issues and potential patient harm. A total of 1560 dietary supplement-related regulatory alerts were identified. Of those, 1287 (83%) were identified through Health Canada, and 273 (18%) were identified through FDA MedWatch. The country of origin of dietary supplements associated with regulatory alerts was not provided in most regulatory alerts; however, when their origin was provided, the United States was the most common. Dietary supplements intended for sexual enhancement were the subject of 33% of all regulatory alerts identified. Products purchased online were the most likely to be associated with a regulatory alert. Dietary supplements intended for sexual enhancement, weight loss, and bodybuilding or athletic performance appeared to pose the greatest risk for patient harm due to product contamination with a pharmaceutical such as a phosphodiesterase-5 inhibitor or sibutramine. Analysis of Canadian and U.S. regulatory alerts concerning dietary supplements revealed that more than 80% of the composite alerts were issued by Health Canada. The most common intended uses of supplements for which alerts were issued were sexual enhancement, weight loss, and bodybuilding or athletic performance. The most common reason for alerts was the presence of a pharmaceutical contaminant. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Kobayashi, Leo; Gosbee, John W; Merck, Derek L
2017-07-01
(1) To develop a clinical microsystem simulation methodology for alarm fatigue research with a human factors engineering (HFE) assessment framework and (2) to explore its application to the comparative examination of different approaches to patient monitoring and provider notification. Problems with the design, implementation, and real-world use of patient monitoring systems result in alarm fatigue. A multidisciplinary team is developing an open-source tool kit to promote bedside informatics research and mitigate alarm fatigue. Simulation, HFE, and computer science experts created a novel simulation methodology to study alarm fatigue. Featuring multiple interconnected simulated patient scenarios with scripted timeline, "distractor" patient care tasks, and triggered true and false alarms, the methodology incorporated objective metrics to assess provider and system performance. Developed materials were implemented during institutional review board-approved study sessions that assessed and compared an experimental multiparametric alerting system with a standard monitor telemetry system for subject response, use characteristics, and end-user feedback. A four-patient simulation setup featuring objective metrics for participant task-related performance and response to alarms was developed along with accompanying structured HFE assessment (questionnaire and interview) for monitor systems use testing. Two pilot and four study sessions with individual nurse subjects elicited true alarm and false alarm responses (including diversion from assigned tasks) as well as nonresponses to true alarms. In-simulation observation and subject questionnaires were used to test the experimental system's approach to suppressing false alarms and alerting providers. A novel investigative methodology applied simulation and HFE techniques to replicate and study alarm fatigue in controlled settings for systems assessment and experimental research purposes.
Hadjidimitrakis, K; Moschovakis, A K; Dalezios, Y; Grantyn, A
2007-05-01
Rapid gaze shifts are often accomplished with coordinated movements of the eyes and head, the relative amplitude of which depends on the starting position of the eyes. The size of gaze shifts is determined by the superior colliculus (SC) but additional processing in the lower brain stem is needed to determine the relative contributions of eye and head components. Models of eye-head coordination often assume that the strength of the command sent to the head controllers is modified by a signal indicative of the eye position. Evidence in favor of this hypothesis has been recently obtained in a study of phasic electromyographic (EMG) responses to stimulation of the SC in head-restrained monkeys (Corneil et al. in J Neurophysiol 88:2000-2018, 2002b). Bearing in mind that the patterns of eye-head coordination are not the same in all species and because the eye position sensitivity of phasic EMG responses has not been systematically investigated in cats, in the present study we used cats to address this issue. We stimulated electrically the intermediate and deep layers of the caudal SC in alert cats and recorded the EMG responses of neck muscles with horizontal and vertical pulling directions. Our data demonstrate that phasic, short latency EMG responses can be modulated by the eye position such that they increase as the eye occupies more and more eccentric positions in the pulling direction of the muscle tested. However, the influence of the eye position is rather modest, typically accounting for only 10-50% of the variance of EMG response amplitude. Responses evoked from several SC sites were not modulated by the eye position.
NASA Astrophysics Data System (ADS)
Fuselier, S.; Allegrini, F.; Bzowski, M.; Dayeh, M. A.; Desai, M. I.; Funsten, H. O.; Galli, A.; Heirtzler, D.; Janzen, P. H.; Kubiak, M. A.; Kucharek, H.; Lewis, W. S.; Livadiotis, G.; McComas, D. J.; Moebius, E.; Petrinec, S. M.; Quinn, M. S.; Schwadron, N.; Sokol, J. M.; Trattner, K. J.
2014-12-01
The Bureau of Meteorology's Space Weather Service operates an alert service for severe space weather events. The service relies on a statistical model which ingests observations of M and X class solar flares at or shortly after the time of the flare to predict the occurrence and severity of terrestrial impacts with a lead time of 1 to 4 days. This model has been operational since 2012 and caters to the needs of critical infrastructure groups in the Australian region. This paper reports on improvements to the forecast model by including SOHO LASCO coronagraph observations of Coronal Mass Ejections (CMEs). The coronagraphs are analysed to determine the Earthward direction parameter and the integrated intensity as a measure of the CME mass. Both of these parameters can help to predict whether a CME will be geo-effective. This work aims to increase the accuracy of the model predictions and lower the rate of false positives, as well as providing an estimate of the expected level of geomagnetic storm intensity.
NASA Astrophysics Data System (ADS)
Freeland, L. E.; Terkildsen, M. B.
2015-12-01
The Bureau of Meteorology's Space Weather Service operates an alert service for severe space weather events. The service relies on a statistical model which ingests observations of M and X class solar flares at or shortly after the time of the flare to predict the occurrence and severity of terrestrial impacts with a lead time of 1 to 4 days. This model has been operational since 2012 and caters to the needs of critical infrastructure groups in the Australian region. This paper reports on improvements to the forecast model by including SOHO LASCO coronagraph observations of Coronal Mass Ejections (CMEs). The coronagraphs are analysed to determine the Earthward direction parameter and the integrated intensity as a measure of the CME mass. Both of these parameters can help to predict whether a CME will be geo-effective. This work aims to increase the accuracy of the model predictions and lower the rate of false positives, as well as providing an estimate of the expected level of geomagnetic storm intensity.
Alertness and cognitive control: Testing the early onset hypothesis.
Schneider, Darryl W
2018-05-01
Previous research has revealed a peculiar interaction between alertness and cognitive control in selective-attention tasks: Congruency effects are larger on alert trials (on which an alerting cue is presented briefly in advance of the imperative stimulus) than on no-alert trials, despite shorter response times (RTs) on alert trials. One explanation for this finding is the early onset hypothesis, which is based on the assumptions that increased alertness shortens stimulus-encoding time and that cognitive control involves gradually focusing attention during a trial. The author tested the hypothesis in 3 experiments by manipulating alertness and stimulus quality (which were intended to shorten and lengthen stimulus-encoding time, respectively) in an arrow-based flanker task involving congruent and incongruent stimuli. Replicating past findings, the alerting manipulation led to shorter RTs but larger congruency effects on alert trials than on no-alert trials. The stimulus-quality manipulation led to longer RTs and larger congruency effects for degraded stimuli than for intact stimuli. These results provide mixed support for the early onset hypothesis, but the author discusses how data and theory might be reconciled if stimulus quality affects stimulus-encoding time and the rate of evidence accumulation in the decision process. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
Chemical Safety Alerts are short publications which explain specific hazards that have become evident through chemical accident investigation efforts. EPA has produced over a dozen Alerts to date. This year's Alert: Managing Chemical Reactivity Hazards
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
What Is Bronchopulmonary Dysplasia?
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
What Is Cardiac Catheterization?
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
What Is Sudden Cardiac Arrest?
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
Blood and Bone Marrow Transplant?
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
What Is Respiratory Distress Syndrome?
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
ARDS (Acute Respiratory Distress Syndrome)
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
Kamaraj R, Dinesh; Bhushan, Kala S; K L, Vandana
2014-01-01
Medline search using key words halitosis, tongue coating, polymerase chain reaction, microbial profile did not reveal any study. Hence, the purpose of the present investigation was to assess the malodor using the organoleptic method and tanita device; to quantify odoriferous microorganisms using Polymerase Chain Reaction technique in chronic periodontitis patients. The study included 30 chronic periodontitis patients. Halitosis was detected using organoleptic assessment & tanita breath alert. Microbial analysis of Pg, Tf & Fn was done using PCR. Plaque index (PI), gingival index (GI), gingival bleeding index (GBI) were recorded. The maximum score of 3 for tongue coating was found in 60% of selected subjects. The tanita breath alert measured VSC level of score 2 in 60% of selected subjects while organoleptic score of 4 was found in 50% of subjects. The maximum mean value of 31.1±36.5 was found to be of F. nucleatum (Fn) followed by P. gingivalis (Pg) (13±13.3) & T. forsythia (Tf) (7.16±8.68) in tongue samples of selected patients. A weak positive correlation was found between VSC levels (tanita score & organoleptic score) and clinical parameters. The halitosis assessment by measuring VSC levels using organoleptic method and tanita breath alert are clinically feasible. Maximum tongue coating was found in 60% of patients. Fn was found comparatively more than the Pg & Tf. A weak positive correlation was found between VSC levels and clinical parameters such as PI, GI & GBI. Thus,the dentist/ periodontist should emphasise on tongue cleaning measures that would reduce the odoriferous microbial load.
Auditory alert systems with enhanced detectability
NASA Technical Reports Server (NTRS)
Begault, Durand R. (Inventor)
2008-01-01
Methods and systems for distinguishing an auditory alert signal from a background of one or more non-alert signals. In a first embodiment, a prefix signal, associated with an existing alert signal, is provided that has a signal component in each of three or more selected frequency ranges, with each signal component in each of three or more selected level at least 3-10 dB above an estimated background (non-alert) level in that frequency range. The alert signal may be chirped within one or more frequency bands. In another embodiment, an alert signal moves, continuously or discontinuously, from one location to another over a short time interval, introducing a perceived spatial modulation or jitter. In another embodiment, a weighted sum of background signals adjacent to each ear is formed, and the weighted sum is delivered to each ear as a uniform background; a distinguishable alert signal is presented on top of this weighted sum signal at one ear, or distinguishable first and second alert signals are presented at two ears of a subject.
Pitois, Frédéric; Vezie, Chantal; Thoraval, Isabelle; Baurès, Estelle
2016-05-01
Cyanobacteria and their toxins are known as a health hazard in recreative and distributed waters. Monitoring data from 2004 to 2011 were collected at regional scale to characterize exposition parameters to microcystins in Brittany (Western France). The data show that cyanobacteria populations are experiencing a composition shift leading to a longer duration of cell densities higher than WHO alert levels 2 and 3. Microcystins however appear to be more frequently detected with subacute concentrations in low cell density samples than in high cell density samples or during bloom episodes. Positive relations are described between microcystin concentrations, detection frequencies and cyanobacteria biovolumes, allowing for a novel definition of alert levels and decision framework following WHO recommendations. Copyright © 2015 Elsevier GmbH. All rights reserved.
Code of Federal Regulations, 2012 CFR
2012-10-01
... alerters shall provide an audio alarm upon expiration of the timing cycle interval. An alerter on a... indication to the operator at least five seconds prior to an audio alarm. The visual indication on an alerter...
What Is a Total Artificial Heart?
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
What Is a Ventricular Assist Device?
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
In the Kitchen with Your Young Child.
ERIC Educational Resources Information Center
Giddings, Louise R.
Under the guidance of alert adults, young children can develop new understandings, learn valuable skills, and acquire positive attitudes toward life and learning by taking part in activities in the kitchen. This book provides ideas that parents and parent surrogates can use to provide experiences in the kitchen that will contribute to children's…
Incorporation of EGPWS in the NASA Ames Research Center 747-400 Flight Simulator
NASA Technical Reports Server (NTRS)
Sallant, Ghislain; DeGennaro, Robert A.
2001-01-01
The NASA Ames Research Center CAE Boeing 747300 flight simulator is used primarily for the study of human factors in aviation safety. The simulator is constantly upgraded to maintain a configuration match to a specific United Airlines aircraft and maintains the highest level of FAA certification to ensure credibility to the results of research programs. United's 747-400 fleet and hence the simulator are transitioning from the older Ground Proximity Warning System (GPWS) to the state-of-the-art Enhanced Ground Proximity Warning System (EGPWS). GPWS was an early attempt to reduce or eliminate Controlled Flight Into Terrain (CFIT). Basic GPWS alerting modes include: excessive descent rate, excessive terrain closure rate, altitude loss after takeoff, unsafe terrain clearance, excessive deviation below glideslope, advisory callouts and windshear alerting. However, since GPWS uses the radar altimeter which looks straight down, ample warning is not always provided. EGPWS retains all of the basic functions of GPWS but adds the ability to look ahead by comparing the aircraft position to an internal database and provide additional alerting and display capabilities. This paper evaluates three methods of incorporating EGPWS in the simulator and describes the implementation and architecture of the preferred option.
Development and implementation of sepsis alert systems
Harrison, Andrew M.; Gajic, Ognjen; Pickering, Brian W.; Herasevich, Vitaly
2016-01-01
Synopsis/Summary Development and implementation of sepsis alert systems is challenging, particularly outside the monitored intensive care unit (ICU) setting. Important barriers to wider use of sepsis alerts include evolving clinical definitions of sepsis, information overload & alert fatigue, due to suboptimal alert performance. Outside the ICU, additional barriers include differences in health care delivery models, charting behaviors, and availability of electronic data. Currently available evidence does not support routine use of sepsis alert systems in clinical practice. However, continuous improvement in both the afferent (data availability and accuracy of detection algorithms) and efferent (evidence-based decision support and smoother integration into clinical workflow) limbs of sepsis alert systems will help translate theoretical advantages into measurable patient benefit. PMID:27229639
NASA Technical Reports Server (NTRS)
Lee, Seung Man; Park, Chunki; Cone, Andrew Clayton; Thipphavong, David P.; Santiago, Confesor
2016-01-01
This presentation contains the analysis results of NAS-wide fast-time simulations with UAS and VFR traffic for a single day for evaluating the performance of Detect-and-Avoid (DAA) alerting and guidance systems. This purpose of this study was to help refine and validate MOPS alerting and guidance requirements. In this study, we generated plots of all performance metrics that are specified by RTCA SC-228 Minimum Operational Performance Standards (MOPS): 1) to evaluate the sensitivity of alerting parameters on the performance metrics of each DAA alert type: Preventive, Corrective, and Warning alerts and 2) to evaluate the effect of sensor uncertainty on DAA alerting and guidance performance.
Wireless clinical alerts for physiologic, laboratory and medication data.
Shabot, M. M.; LoBue, M.; Chen, J.
2000-01-01
A fully interfaced clinical information system (CIS) contains physiologic, laboratory, blood gas, medication and other data that can be used as the information base for a comprehensive alerting system. Coupled with an event driven rules engine, a CIS can generate clinical alerts which may both prevent medical errors and assist caregivers in responding to critical events in a timely way. The authors have developed a clinical alerting system which delivers alerts and reminders to clinicians in real time via a alphanumeric display pagers. This paper will describe the system, the type and number of alerts generated, and the impact on clinical practice. A major issue remains in measuring the impact of wireless alerts on patient outcomes. PMID:11079992
Alerts in mobile healthcare applications: requirements and pilot study.
Kafeza, Eleanna; Chiu, Dickson K W; Cheung, S C; Kafeza, Marina
2004-06-01
Recent advances in mobile technologies have greatly extended traditional communication technologies to mobile devices. At the same time, healthcare environments are by nature "mobile" where doctors and nurses do not have fixed workspaces. Irregular and exceptional events are generated in daily hospital routines, such as operations rescheduling, laboratory/examination results, and adverse drug events. These events may create requests that should be delivered to the appropriate person at the appropriate time. Those requests that are classified as urgent are referred to as alerts. Efficient routing and monitoring of alerts are keys to quality and cost-effective healthcare services. Presently, these are generally handled in an ad hoc manner. In this paper, we propose the use of a healthcare alert management system to handle these alert messages systematically. We develop a model for specifying alerts that are associated with medical tasks and a set of parameters for their routing. We design an alert monitor that matches medical staff and their mobile devices to receive alerts, based on the requirements of these alerts. We also propose a mechanism to handle and reroute, if necessary, an alert message when it has not been acknowledged within a specific deadline.
Wearable PPG sensor based alertness scoring system.
Dey, Jishnu; Bhowmik, Tanmoy; Sahoo, Saswata; Tiwari, Vijay Narayan
2017-07-01
Quantifying mental alertness in today's world is important as it enables the person to adopt lifestyle changes for better work efficiency. Miniaturized sensors in wearable devices have facilitated detection/monitoring of mental alertness. Photoplethysmography (PPG) sensors through Heart Rate Variability (HRV) offer one such opportunity by providing information about one's daily alertness levels without requiring any manual interference from the user. In this paper, a smartwatch based alertness estimation system is proposed. Data collected from PPG sensor of smartwatch is processed and fed to machine learning based model to get a continuous alertness score. Utility functions are designed based on statistical analysis to give a quality score on different stages of alertness such as awake, long sleep and short duration power nap. An intelligent data collection approach is proposed in collaboration with the motion sensor in the smartwatch to reduce battery drainage. Overall, our proposed wearable based system provides a detailed analysis of alertness over a period in a systematic and optimized manner. We were able to achieve an accuracy of 80.1% for sleep/awake classification along with alertness score. This opens up the possibility for quantifying alertness levels using a single PPG sensor for better management of health related activities including sleep.
Closing the Loop in ICU Decision Support: Physiologic Event Detection, Alerts, and Documentation
Norris, Patrick R.; Dawant, Benoit M.
2002-01-01
Automated physiologic event detection and alerting is a challenging task in the ICU. Ideally care providers should be alerted only when events are clinically significant and there is opportunity for corrective action. However, the concepts of clinical significance and opportunity are difficult to define in automated systems, and effectiveness of alerting algorithms is difficult to measure. This paper describes recent efforts on the Simon project to capture information from ICU care providers about patient state and therapy in response to alerts, in order to assess the value of event definitions and progressively refine alerting algorithms. Event definitions for intracranial pressure and cerebral perfusion pressure were studied by implementing a reliable system to automatically deliver alerts to clinical users’ alphanumeric pagers, and to capture associated documentation about patient state and therapy when the alerts occurred. During a 6-month test period in the trauma ICU at Vanderbilt University Medical Center, 530 alerts were detected in 2280 hours of data spanning 14 patients. Clinical users electronically documented 81% of these alerts as they occurred. Retrospectively classifying documentation based on therapeutic actions taken, or reasons why actions were not taken, provided useful information about ways to potentially improve event definitions and enhance system utility.
Emergency Department Real Time Location System Patient and Equipment Tracking
2014-10-01
accomplishments/Reportable Outcomes Patient Tagging: Getting staff to embrace the change in their workflow and apply the RFID tag and band as well as getting...goes on if a patient passes the exit with a RFID tag still on. We have received the device however the vendor is researching how best to utilize the...technology to meet the need. The ability to limit the range for reading an RFID tag to prevent false alerts is presently being worked on. Tag
Aspirin to Prevent a First Heart Attack or Stroke
... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...
Pilot Non-Conformance to Alerting System Commands During Closely Spaced Parallel Approaches
NASA Technical Reports Server (NTRS)
Pritchett, Amy Ruth; Hansman, R. John; Corker, Kevin (Technical Monitor)
1997-01-01
Cockpit alerting systems monitor potentially hazardous situations, both inside and outside the aircraft. When a hazard is projected to occur, the alerting system displays alerts and/or command decisions to the pilot. However, pilots have been observed to not conform to alerting system commands by delaying their response or by not following the automatic commands exactly. This non-conformance to the automatic alerting system can reduce its benefit. Therefore, a need exists to understand the causes and effects of pilot non-conformance in order to develop automatic alerting systems whose commands the pilots are more likely to follow. These considerations were examined through flight simulator evaluations of the collision avoidance task during closely spaced parallel approaches. This task provided a useful case-study because the effects of non-conformance can be significant, given the time-critical nature of the task. A preliminary evaluation of alerting systems identified non-conformance in over 40% of the cases and a corresponding drop in collision avoidance performance. A follow-on experiment found subjects' alerting and maneuver selection criteria were consistent with different strategies than those used by automatic systems, indicating the pilot may potentially disagree with the alerting system if the pilot attempts to verify automatic alerts and commanded avoidance maneuvers. A final experiment found supporting automatic alerts with the explicit display of its underlying criteria resulted in more consistent subject reactions. In light of these experimental results, a general discussion of pilot non-conformance is provided. Contributing factors in pilot non-conformance include a lack of confidence in the automatic system and mismatches between the alerting system's commands and the pilots' own decisions based on the information available to them. The effects of non-conformance on system performance are discussed. Possible methods of reconciling mismatches are given, and design considerations for alerting systems which alleviate the problem of non-conformance are provided.
Beck, J R; Fung, K; Lopez, H; Mongero, L B; Argenziano, M
2015-01-01
Delayed perfusionist identification and reaction to abnormal clinical situations has been reported to contribute to increased mortality and morbidity. The use of automated data acquisition and compliance safety alerts has been widely accepted in many industries and its use may improve operator performance. A study was conducted to evaluate the reaction time of perfusionists with and without the use of compliance alert. A compliance alert is a computer-generated pop-up banner on a pump-mounted computer screen to notify the user of clinical parameters outside of a predetermined range. A proctor monitored and recorded the time from an alert until the perfusionist recognized the parameter was outside the desired range. Group one included 10 cases utilizing compliance alerts. Group 2 included 10 cases with the primary perfusionist blinded to the compliance alerts. In Group 1, 97 compliance alerts were identified and, in group two, 86 alerts were identified. The average reaction time in the group using compliance alerts was 3.6 seconds. The average reaction time in the group not using the alerts was nearly ten times longer than the group using computer-assisted, real-time data feedback. Some believe that real-time computer data acquisition and feedback improves perfusionist performance and may allow clinicians to identify and rectify potentially dangerous situations. © The Author(s) 2014.
Engels, Melanie J.
2015-01-01
Background: High-alert medications pose a greater risk of causing significant harm to patients if used in error. The Joint Commission requires that hospitals define institution-specific high-alert medications and implement processes to ensure safe medication use. Method: Nursing, pharmacy, and prescribers were asked to voluntarily complete a 34-question survey to assess their knowledge, experience, and perceptions regarding high-alert medications in an academic hospital. Results: The majority of respondents identified the organization’s high-alert medications, the consequences of an error involving a high-alert medication, and the reversal agent. Most of the risk-reduction strategies within the institution were viewed as being effective by respondents. Forty-five percent of the respondents utilized a high-alert medication in the previous 24 hours. Only 14.2% had experienced an error with a high-alert medication in the previous 12 months, with 46% being near misses. The survey found the 5 rights for medication administration were not being utilized consistently. Respondents indicated that work experience or hospital orientation is the preferred learning experience for high-alert medications. Conclusions: This study assessed all disciplines involved in the medication use process. Perceptions about high-alert medications differ between disciplines. Ongoing discipline-specific education is required to ensure that individuals accept accountability in the medication use process and to close knowledge gaps on high-alert medications and risk-reduction strategies. PMID:26446747
AmberAlert / DPS / DHSEM / AAB
cooperative public service alert to aid in the safe recovery of abducted children. The Alaska AMBER Alert children to aid in their safe return. AMBER Alert Hotline: 866-AKAMBER - (866-252-6237) State of Alaska
Analysis of Alerting System Failures in Commercial Aviation Accidents
NASA Technical Reports Server (NTRS)
Mumaw, Randall J.
2017-01-01
The role of an alerting system is to make the system operator (e.g., pilot) aware of an impending hazard or unsafe state so the hazard can be avoided or managed successfully. A review of 46 commercial aviation accidents (between 1998 and 2014) revealed that, in the vast majority of events, either the hazard was not alerted or relevant hazard alerting occurred but failed to aid the flight crew sufficiently. For this set of events, alerting system failures were placed in one of five phases: Detection, Understanding, Action Selection, Prioritization, and Execution. This study also reviewed the evolution of alerting system schemes in commercial aviation, which revealed naive assumptions about pilot reliability in monitoring flight path parameters; specifically, pilot monitoring was assumed to be more effective than it actually is. Examples are provided of the types of alerting system failures that have occurred, and recommendations are provided for alerting system improvements.