Dachman, Abraham H.; Wroblewski, Kristen; Vannier, Michael W.; Horne, John M.
2014-01-01
Computed tomography (CT) colonography is a screening modality used to detect colonic polyps before they progress to colorectal cancer. Computer-aided detection (CAD) is designed to decrease errors of detection by finding and displaying polyp candidates for evaluation by the reader. CT colonography CAD false-positive results are common and have numerous causes. The relative frequency of CAD false-positive results and their effect on reader performance on the basis of a 19-reader, 100-case trial shows that the vast majority of CAD false-positive results were dismissed by readers. Many CAD false-positive results are easily disregarded, including those that result from coarse mucosa, reconstruction, peristalsis, motion, streak artifacts, diverticulum, rectal tubes, and lipomas. CAD false-positive results caused by haustral folds, extracolonic candidates, diminutive lesions (<6 mm), anal papillae, internal hemorrhoids, varices, extrinsic compression, and flexural pseudotumors are almost always recognized and disregarded. The ileocecal valve and tagged stool are common sources of CAD false-positive results associated with reader false-positive results. Nondismissable CAD soft-tissue polyp candidates larger than 6 mm are another common cause of reader false-positive results that may lead to further evaluation with follow-up CT colonography or optical colonoscopy. Strategies for correctly evaluating CAD polyp candidates are important to avoid pitfalls from common sources of CAD false-positive results. ©RSNA, 2014 PMID:25384290
Ikeda, Kei; Narita, Akihiro; Ogasawara, Michihiro; Ohno, Shigeru; Kawahito, Yutaka; Kawakami, Atsushi; Ito, Hiromu; Matsushita, Isao; Suzuki, Takeshi; Misaki, Kenta; Ogura, Takehisa; Kamishima, Tamotsu; Seto, Yohei; Nakahara, Ryuichi; Kaneko, Atsushi; Nakamura, Takayuki; Henmi, Mihoko; Fukae, Jun; Nishida, Keiichiro; Sumida, Takayuki; Koike, Takao
2016-01-01
We aimed to identify causes of false-positives in ultrasound scanning of synovial/tenosynovial/bursal inflammation and provide corresponding imaging examples. We first performed systematic literature review to identify previously reported causes of false-positives. We next determined causes of false-positives and corresponding example images for educational material through Delphi exercises and discussion by 15 experts who were an instructor and/or a lecturer in the 2013 advanced course for musculoskeletal ultrasound organized by Japan College of Rheumatology Committee for the Standardization of Musculoskeletal Ultrasonography. Systematic literature review identified 11 articles relevant to sonographic false-positives of synovial/tenosynovial inflammation. Based on these studies, 21 candidate causes of false-positives were identified in the consensus meeting. Of these items, 11 achieved a predefined consensus (≥ 80%) in Delphi exercise and were classified as follows: (I) Gray-scale assessment [(A) non-specific synovial findings and (B) normal anatomical structures which can mimic synovial lesions due to either their low echogenicity or anisotropy]; (II) Doppler assessment [(A) Intra-articular normal vessels and (B) reverberation)]. Twenty-four corresponding examples with 49 still and 23 video images also achieved consensus. Our study provides a set of representative images that can help sonographers to understand false-positives in ultrasound scanning of synovitis and tenosynovitis.
Skin irritation, false positives and the local lymph node assay: a guideline issue?
Basketter, David A; Kimber, Ian
2011-10-01
Since the formal validation and regulatory acceptance of the local lymph node assay (LLNA) there have been commentaries suggesting that the irritant properties of substances can give rise to false positives. As toxicology aspires to progress rapidly towards the age of in vitro alternatives, it is of increasing importance that issues relating to assay selectivity and performance are understood fully, and that true false positive responses are distinguished clearly from those that are simply unpalatable. In the present review, we have focused on whether skin irritation per se is actually a direct cause of true false positive results in the LLNA. The body of published work has been examined critically and considered in relation to our current understanding of the mechanisms of skin irritation and skin sensitisation. From these analyses it is very clear that, of itself, skin irritation is not a cause of false positive results. The corollary is, therefore, that limiting test concentrations in the LLNA for the purpose of avoiding skin irritation may lead, unintentionally, to false negatives. Where a substance is a true false positive in the LLNA, the classic example being sodium lauryl sulphate, explanations for that positivity will have to reach beyond the seductive, but incorrect, recourse to its skin irritation potential. Copyright © 2011 Elsevier Inc. All rights reserved.
Case Reports of Aripiprazole Causing False-Positive Urine Amphetamine Drug Screens in Children.
Kaplan, Justin; Shah, Pooja; Faley, Brian; Siegel, Mark E
2015-12-01
Urine drug screens (UDSs) are used to identify the presence of certain medications. One limitation of UDSs is the potential for false-positive results caused by cross-reactivity with other substances. Amphetamines have an extensive list of cross-reacting medications. The literature contains reports of false-positive amphetamine UDSs with multiple antidepressants and antipsychotics. We present 2 cases of presumed false-positive UDSs for amphetamines after ingestion of aripiprazole. Case 1 was a 16-month-old girl who accidently ingested 15 to 45 mg of aripiprazole. She was lethargic and ataxic at home with 1 episode of vomiting containing no identifiable tablets. She remained sluggish with periods of irritability and was admitted for observation. UDS on 2 consecutive days came back positive for amphetamines. Case 2 was of a 20-month-old girl who was brought into the hospital after accidental ingestion of an unknown quantity of her father's medications which included aripiprazole. UDS on the first day of admission came back positive only for amphetamines. Confirmatory testing with gas chromatography-mass spectrometry (GC-MS) on the blood and urine samples were also performed for both patients on presentation to detect amphetamines and were subsequently negative. Both patients returned to baseline and were discharged from the hospital. To our knowledge, these cases represent the first reports of false-positive amphetamine urine drug tests with aripiprazole. In both cases, aripiprazole was the drug with the highest likelihood of causing the positive amphetamine screen. The implications of these false-positives include the possibility of unnecessary treatment and monitoring of patients. Copyright © 2015 by the American Academy of Pediatrics.
False-positive cryptococcal antigen latex agglutination caused by disinfectants and soaps.
Blevins, L B; Fenn, J; Segal, H; Newcomb-Gayman, P; Carroll, K C
1995-01-01
Five disinfectants or soaps were tested to determine if any could be responsible for false-positive results obtained with the Latex-Crypto Antigen Detection System kit (Immuno-Mycologics, Inc., Norman, Okla.). Three disinfectants or soaps (Derma soap, 7X, and Bacdown) produced false-positive agglutination after repeated washing of ring slides during testing of a known negative cerebrospinal fluid specimen. PMID:7650214
Nel, Jeremy S; Lippincott, Christopher K; Berhanu, Rebecca; Spencer, David C; Sanne, Ian M; Ive, Prudence
2017-06-02
We retrospectively reviewed the Determine TB-LAM lateral flow assay (LF-LAM) results among HIV-infected patients with disseminated nontuberculous mycobacterial (NTM) disease. LF-LAM was positive in 19/21 patients without evidence of tuberculosis coinfection. Although tuberculosis-NTM coinfection may have been underdiagnosed, our results suggest that disseminated NTM disease may cause false-positive LF-LAM results. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Pisciotta, John M.; Rath, Damon F.; Stanek, Paul A.; Flanery, D. Michael; Harwood, Valerie J.
2002-01-01
The Colilert-18 system for enumeration of total coliforms and Escherichia coli is approved by the U.S. Environmental Protection Agency for use in drinking water analysis and is also used by various agencies and research studies for enumeration of indicator organisms in fresh and saline waters. During monitoring of Pinellas County, Fla., marine waters, estimates of E. coli numbers (by Colilert-18) frequently exceeded fecal coliform counts (by membrane filtration) by 1 to 3 orders of magnitude. Samples from freshwater sites did not display similar discrepancies. Fecal coliforms, including E. coli, could be cultured from 100% of yellow fluorescent wells (denoting E. coli-positive results) inoculated with freshwater samples but could be cultured from only 17.1% of the “positive” wells inoculated with marine samples. Ortho-nitrophenyl-β-d-galactopyranoside (ONPG)-positive or 4-methylumbelliferyl-β-d-glucuronide (MUG)-positive noncoliform bacteria were readily cultured from Colilert-18 test wells inoculated with marine samples. Filtered cell-free seawater did not cause false positives. Coculture preparations of as few as 5 CFU of Vibrio cholerae (ONPG positive) and Providencia sp. (MUG positive) ml−1 inoculated into Colilert-18 caused false-positive E. coli results. Salinity conditions influenced coculture results, as the concentration of coculture inoculum required to cause false positives in most wells increased from about 5 CFU ml−1 in seawater diluted 1:10 with freshwater to ≈5,000 CFU ml−1 in seawater diluted 1:20 with freshwater. Estimated E. coli numbers in various marine water samples processed at the 1:10 dilution ranged from 10 to 7,270 CFU·100 ml−1, while E. coli numbers in the same samples processed at the 1:20 dilution did not exceed 40 CFU·100 ml−1. The lower estimates of E. coli numbers corresponded well with fecal coliform counts by membrane filtration. This study indicates that assessment of E. coli in subtropical marine waters by Colilert-18 is not accurate when the recommended 1:10 sample dilution is used. The results suggest that greater dilution may diminish the false-positive problem, but further study of this possibility is recommended. PMID:11823188
Pavletic, Adriana J; Marques, Adriana R
2017-07-15
False-positive serology for Lyme disease was reported in patients with acute infectious mononucleosis. Here we describe 2 patients with early disseminated Lyme disease who were misdiagnosed with infectious mononucleosis based on false-positive tests for primary Epstein-Barr virus infection. Published by Oxford University Press for the Infectious Diseases Society of America 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Zhou, Yang; Utsunomiya, Yuri T; Xu, Lingyang; Hay, El Hamidi Abdel; Bickhart, Derek M; Sonstegard, Tad S; Van Tassell, Curtis P; Garcia, Jose Fernando; Liu, George E
2016-07-06
We compared CNV region (CNVR) results derived from 1,682 Nellore cattle with equivalent results derived from our previous analysis of Bovine HapMap samples. By comparing CNV segment frequencies between different genders and groups, we identified 9 frequent, false positive CNVRs with a total length of 0.8 Mbp that were likely caused by assembly errors. Although there was a paucity of lineage specific events, we did find one 54 kb deletion on chr5 significantly enriched in Nellore cattle. A few highly frequent CNVRs present in both datasets were detected within genomic regions containing olfactory receptor, ATP-binding cassette, and major histocompatibility complex genes. We further evaluated their impacts on downstream bioinformatics and CNV association analyses. Our results revealed pitfalls caused by false positive and lineage-differential copy number variations and will increase the accuracy of future CNV studies in both taurine and indicine cattle.
Mordang, Jan-Jurre; Gubern-Mérida, Albert; Bria, Alessandro; Tortorella, Francesco; den Heeten, Gerard; Karssemeijer, Nico
2017-04-01
Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated by microcalcification detection algorithms. We aim at reducing the number of obvious false-positive findings by adding an additional step in the detection method. In this step, a multiclass machine learning method is implemented in which dedicated classifiers learn to recognize the patterns of obvious false-positive subtypes that occur most frequently. The method is compared to a conventional two-class approach, where all false-positive subtypes are grouped together in one class, and to the baseline CADe system without the new false-positive removal step. The methods are evaluated on an independent dataset containing 1,542 screening examinations of which 80 examinations contain malignant microcalcifications. Analysis showed that the multiclass approach yielded a significantly higher sensitivity compared to the other two methods (P < 0.0002). At one obvious false positive per 100 images, the baseline CADe system detected 61% of the malignant examinations, while the systems with the two-class and multiclass false-positive reduction step detected 73% and 83%, respectively. Our study showed that by adding the proposed method to a CADe system, the number of obvious false positives can decrease significantly (P < 0.0002). © 2017 American Association of Physicists in Medicine.
Patriquin, Glenn; LeBlanc, Jason; Heinstein, Charles; Roberts, Catherine; Lindsay, Robbin; Hatchette, Todd F
2016-03-01
Increased rates of Lyme disease and syphilis in the same geographic area prompted an assessment of screening test cross-reactivity. This study supports the previously described cross-reactivity of Lyme screening among syphilis-positive sera and reports evidence against the possibility of false-positive syphilis screening tests resulting from previous Borrelia burgdorferi infection. Copyright © 2016 Elsevier Inc. All rights reserved.
Zilli, Alessandra; Fanetti, Ilaria; Conte, Dario; Massironi, Sara
Gallium-68 DOTA-peptide positron emission tomography/computed tomography ( 68 Ga-PET/CT) has emerged as a promising tool for the diagnosis and staging of gastro-entero-pancreatic neoplasms, thanks to its high sensitivity and specificity. Heterotopic pancreas, which is relatively rare, has never been reported as a possible cause of false positives of 68 Ga-PET/CT. We report on the first case of a heterotopic pancreas showing pathological uptake at 68 Ga-PET/CT, thus mimicking an intestinal neuroendocrine tumor. The present case suggests that heterotopic pancreas should be included among the possible causes of false positives at 68 Ga PET. Copyright © 2018 Elsevier Inc. All rights reserved.
Hiatal hernia uptake of iodine-131 mimicking mediastinal metastasis of papillary thyroid carcinoma.
Haghighatafshar, Mahdi; Khajehrahimi, Farnaz
2015-01-01
There are a few case reports of hiatal hernia demonstrating thoracic uptake on I-131 scintigraphy. In this case, high thyroglobulin levels in combination with misinterpretation of I-131 uptake in the mediastinum, leaded to mismanagement of the patient. Here we present a case of focal I-131 uptake within a hiatal hernia initially mimicking an isolated mediastinal metastasis. There are many potential causes of false-positive I-131 scan result. In this case, adjunctive chest computed tomography and gastroesophageal barium study helped to elucidate the true nature of this I-131 uptake. False-positive findings may be caused by a wide variety of nonthyroidal carcinomas, which can concentrate radioiodine or from skin contamination. Several organs, such as the gastric, salivary glands, renal cyst, pericardial effusion, and ovarian can accumulate I-131. It should be borne in mind as a potential source of false-positive whole-body I-131 imaging.
Kiemde, Francois; Bonko, Massa Dit Achille; Tahita, Marc Christian; Lompo, Palpouguini; Rouamba, Toussaint; Tinto, Halidou; van Hensbroek, Michael Boele; Mens, Petra F; Schallig, Henk D F H
2017-07-20
It remains challenging to distinguish malaria from other fever causing infections, as a positive rapid diagnostic test does not always signify a true active malaria infection. This study was designed to determine the influence of other causes of fever, prior anti-malarial treatment, and a possible seasonality of the performance of a PfHRP2 RDT for the diagnosis of malaria in children under-5 years of age living in a malaria endemic area. A prospective etiology study was conducted in 2015 among febrile children under 5 years of age in Burkina Faso. In order to assess the influence of other febrile illnesses, prior treatment and seasonality on the performance of a PfHRP2 RDT in diagnosing malaria, the RDT results were compared with the gold standard (expert microscopic diagnosis of Plasmodium falciparum) and test results were analysed by assuming that prior anti-malarial use and bacterial/viral infection status would have been known prior to testing. To assess bacterial and viral infection status blood, urine and stool samples were analysed. In total 683 blood samples were analysed with microscopy and RDT-PfHRP2. Plasmodium falciparum malaria was diagnosed in 49.8% (340/683) by microscopy compared to 69.5% (475/683) by RDT-PfHRP2. The RDT-PfHRP2 reported 29.7% (141/475) false positive results and 1.8% (6/340) false negative cases. The RDT-PfHRP2 had a high sensitivity (98.2%) and negative predictive value (97.1%), but a low specificity (58.9%) and positive predictive value (70.3%). Almost 50% of the alternative cause of fever were diagnosed by laboratory testing in the RDT false positive malaria group. The use of a malaria RDT-PfHRP2 in a malaria endemic area may cause misdiagnosis of the actual cause of fever due to false positive test results. The development of a practical diagnostic tool to screen for other causes of fever in malaria endemic areas is required to save lives.
Female False Positive Exercise Stress ECG Testing - Fact Verses Fiction.
Fitzgerald, Benjamin T; Scalia, William M; Scalia, Gregory M
2018-03-07
Exercise stress testing is a well validated cardiovascular investigation. Accuracy for treadmill stress electrocardiograph (ECG) testing has been documented at 60%. False positive stress ECGs (exercise ECG changes with non-obstructive disease on anatomical testing) are common, especially in women, limiting the effectiveness of the test. This study investigates the incidence and predictors of false positive stress ECG findings, referenced against stress echocardiography (SE) as a standard. Stress echocardiography was performed using the Bruce treadmill protocol. False positive stress ECG tests were defined as greater than 1mm of ST depression on ECG during exertion, without pain, with a normal SE. Potential causes for false positive tests were recorded before the test. Three thousand consecutive negative stress echocardiograms (1036 females, 34.5%) were analysed (age 59+/-14 years. False positive (F+) stress ECGs were documented in 565/3000 tests (18.8%). F+ stress ECGs were equally prevalent in females (194/1036, 18.7%) and males (371/1964, 18.9%, p=0.85 for the difference). Potential causes (hypertension, left ventricular hypertrophy, known coronary disease, arrhythmia, diabetes mellitus, valvular heart disease) were recorded in 36/194 (18.6%) of the female F+ ECG tests and 249/371 (68.2%) of the male F+ ECG tests (p<0.0001 for the difference). These data suggest that F+ stress ECG tests are frequent and equally common in women and men. However, most F+ stress ECGs in men can be predicted before the test, while most in women cannot. Being female may be a risk factor in itself. These data reinforce the value of stress imaging, particularly in women. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.
Wakefield, Jerome C; First, Michael B
2012-02-01
The Diagnostic and Statistical Manual of Mental Disorders (DSM) definition of mental disorder requires that symptoms be caused by a dysfunction in the individual; when dysfunction is absent, symptoms represent normal-range distress or eccentricity and, if diagnosed as a mental disorder, are false positives. We hypothesized that because of psychiatry's lack of direct laboratory tests to distinguish dysfunction from normal-range distress, the context in which symptoms occur (eg, lack of imminent danger in a panic attack) is often essential to determining whether symptoms are caused by a dysfunction. If this is right, then the DSM diagnostic criteria should include many contextual criteria added to symptom syndromes to prevent dysfunction false positives. Despite their potential importance, such contextual criteria have not been previously reviewed. We, thus, systematically reviewed DSM categories to establish the extent of such uses of contextual criteria and created a typology of such uses. Of 111 sampled categories, 68 (61%) used context to prevent dysfunction false positives. Contextual criteria fell into 7 types: (1) exclusion of specific false-positive scenarios; (2) requiring that patients experience preconditions for normal responses (eg, requiring that individuals experience adequate sexual stimulation before being diagnosed with sexual dysfunctions); (3) requiring that symptoms be disproportionate relative to circumstances; (4) for childhood disorders, requiring that symptoms be developmentally inappropriate; (5) requiring that symptoms occur in multiple contexts; (6) requiring a substantial discrepancy between beliefs and reality; and (7) a residual category. Most DSM categories include contextual criteria to eliminate false-positive diagnoses and increase validity of descriptive criteria. Future revisions should systematically evaluate each category's need for contextual criteria. Copyright © 2012 Elsevier Inc. All rights reserved.
How does negative emotion cause false memories?
Brainerd, C J; Stein, L M; Silveira, R A; Rohenkohl, G; Reyna, V F
2008-09-01
Remembering negative events can stimulate high levels of false memory, relative to remembering neutral events. In experiments in which the emotional valence of encoded materials was manipulated with their arousal levels controlled, valence produced a continuum of memory falsification. Falsification was highest for negative materials, intermediate for neutral materials, and lowest for positive materials. Conjoint-recognition analysis produced a simple process-level explanation: As one progresses from positive to neutral to negative valence, false memory increases because (a) the perceived meaning resemblance between false and true items increases and (b) subjects are less able to use verbatim memories of true items to suppress errors.
Khorrami, Seyed Mahmood Seyed; Mokhtari-Azad, Talat; Yavarian, Jila; Nasab, Gazal Sadat Fatemi; Naseri, Maryam; Jandaghi, Nazanin Zahra Shafiei
2015-11-01
Rubella is a mild self-limiting contagious viral disease caused by the rubella virus (RV). Although symptoms are often mild, the concern is centralized around the possible effect on a fetus growth and development in case of primary infection during early months of pregnancy. Recently acquired rubella is commonly confirmed by RV-specific IgM antibody detection in the serum. However, rubella primary infection is not always the only cause of IgM positivity. Other possible causes of rubella IgM positivity may include IgM persistence following vaccination or naturally acquired infection or even re-infection. Moreover, nonspecific IgM reactivity can cause false-positive results. There are few articles to differentiate the aetiology of rash in rubella-like illnesses. However, limited studies have been conducted on clarifying the source of IgM positivity in these cases. This article reports the study of 10,896 clinical cases demonstrating rubella-like illness between 2011 and 2013 in Iran. The rate of IgM positivity among these cases was 0.52% (57 cases). As predicted based on the high coverage of vaccination in Iran fewer than 16% of cases with ELISA IgM positive result, were due to current rubella primary infections. The greater part of the positive IgM reactions occurred in cross reactivity with other viruses (31.6%) or in prolonged IgM response post vaccination (24.6%). This research confirmed that the positive result of rubella IgM assay in vaccinated individuals is mainly caused by prolonged IgM production, rubella re-infection, and false positivity due to infection with other viruses, rather than the rubella primary infection itself. © 2015 Wiley Periodicals, Inc.
Assessment of potential false positives via orbitrap-based untargeted lipidomics from rat tissues.
Xu, Lina; Wang, Xueying; Jiao, Yupei; Liu, Xiaohui
2018-02-01
Untargeted lipidomics is increasingly popular due to the broad coverage of lipid species. Data dependent MS/MS acquisition is commonly used in order to acquire sufficient information for confident lipid assignment. However, although lipids are identified based on MS/MS confirmation, a number of false positives are still observed. Here, we discuss several causes of introducing lipid false identifications in untargeted analysis. Phosphotidylcholines and cholesteryl esters generate in-source fragmentation to produce dimethylated phosphotidylethanolamine and free cholesterol. Dimerization of fatty acid results in false identification of fatty acid ester of hydroxyl fatty acid. Realizing these false positives is able to improve confidence of results acquired from untargeted analysis. Besides, thresholds are established for lipids identified using LipidSearch v4.1.16 software to reduce unreliable results. Copyright © 2017 Elsevier B.V. All rights reserved.
Willcox, M C
1976-04-01
Agglutinins reacting with normal and tanned sheep erythrocytes were the probable cause of false positive reactions given by 51 of 214 Liberian sera when using a commercial passive-haemagglutination test for hepatitis-B surface antigen. Absorption showed these agglutinins to be identical to those described earlier in Nigerian sera. Rheumatoid factor and anti-sheep-serum antibodies although present in 12 and five per cent respectively of all sera were not responsible for any false positive reactions. The practical conclusion is that such tests, based on sheep erythrocytes are unsuitable for screening this population.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fowler, J.E. Jr.; Platoff, G.E.; Kubrock, C.A.
1982-01-01
Among 17 men who had received seemingly curative treatment for unilateral non-seminomatous germ cell tumors for the testis and who had consistently normal serum human chorionic gonadotropin (HCG) levels at a reference laboratory, 7 (41%) had at least one falsely positive commercial serum HCG determination. To investigate the cause of these falsely positive determinations the authors measured the cross reactivity of luteinizing hormone (LH) and follicle stimulating hormone (FSH) standards in the commercial HCG assay, and studied the relationships between commercial HCG levels and serum LH levels, serum FSH levels and gonadal status in men with and without normal gonadalmore » function. The falsely positive HCG determinations appeared to be due to elevated serum LH levels and cross reactivity of LH in the commercial HCG assay because: 1) there was substantial cross reactivity of the LH standards in the commercial assay, 2) the serum LH was elevated in four of six men with solitary testes, 3) there was a striking correlation between elevated serum LH levels and falsely elevated commercial HCG levels in ten men with solitary or absent testes, and 4) there were no falsely positive HCG determinations in 13 normal men but there were falsely positive HCG determinations in seven of ten anorchid men.« less
False Positives in Exoplanet Detection
NASA Astrophysics Data System (ADS)
Leuquire, Jacob; Kasper, David; Jang-Condell, Hannah; Kar, Aman; Sorber, Rebecca; Suhaimi, Afiq; KELT (Kilodegree Extremely Little Telescope)
2018-06-01
Our team at the University of Wyoming uses a 0.6 m telescope at RBO (Red Buttes Observatory) to help confirm results on potential exoplanet candidates from low resolution, wide field surveys shared by the KELT (Kilodegree Extremely Little Telescope) team. False positives are common in this work. We carry out transit photometry, and this method comes with special types of false positives. The most common false positive seen at the confirmation level is an EB (eclipsing binary). Low resolution images are great in detecting multiple sources for photometric dips in light curves, but they lack the precision to decipher single targets at an accurate level. For example, target star KC18C030621 needed RBO’s photometric precision to determine there was a nearby EB causing exoplanet type light curves. Identifying false positives with our telescope is important work because it helps eliminate the waste of time taken by more expensive telescopes trying to rule out negative candidate stars. It also furthers the identification of other types of photometric events, like eclipsing binaries, so they can be studied on their own.
Chung, Shimin J; Krishnan, Prabha U; Leo, Yee Sin
2015-02-01
Early diagnosis of dengue has been made easier in recent years owing to the advancement in diagnostic technologies. The rapid non-structural protein 1 (NS1) test strip is widely used in many developed and developing regions at risk of dengue. Despite the relatively high specificity of this test, we recently encountered two cases of false-positive dengue NS1 antigen in patients with underlying hematological malignancies. We reviewed the literature for causes of false-positive dengue NS1. © The American Society of Tropical Medicine and Hygiene.
Induction detection of concealed bulk banknotes
NASA Astrophysics Data System (ADS)
Fuller, Christopher; Chen, Antao
2012-06-01
The smuggling of bulk cash across borders is a serious issue that has increased in recent years. In an effort to curb the illegal transport of large numbers of paper bills, a detection scheme has been developed, based on the magnetic characteristics of bank notes. The results show that volumes of paper currency can be detected through common concealing materials such as plastics, cardboard, and fabrics making it a possible potential addition to border security methods. The detection scheme holds the potential of also reducing or eliminating false positives caused by metallic materials found in the vicinity, by observing the stark difference in received signals caused by metal and currency. The detection scheme holds the potential to detect for both the presence and number of concealed bulk notes, while maintaining the ability to reduce false positives caused by metal objects.
Trinh, Tony W; Glazer, Daniel I; Sadow, Cheryl A; Sahni, V Anik; Geller, Nina L; Silverman, Stuart G
2018-03-01
To determine test characteristics of CT urography for detecting bladder cancer in patients with hematuria and those undergoing surveillance, and to analyze reasons for false-positive and false-negative results. A HIPAA-compliant, IRB-approved retrospective review of reports from 1623 CT urograms between 10/2010 and 12/31/2013 was performed. 710 examinations for hematuria or bladder cancer history were compared to cystoscopy performed within 6 months. Reference standard was surgical pathology or 1-year minimum clinical follow-up. False-positive and false-negative examinations were reviewed to determine reasons for errors. Ninety-five bladder cancers were detected. CT urography accuracy: was 91.5% (650/710), sensitivity 86.3% (82/95), specificity 92.4% (568/615), positive predictive value 63.6% (82/129), and negative predictive value was 97.8% (568/581). Of 43 false positives, the majority of interpretation errors were due to benign prostatic hyperplasia (n = 12), trabeculated bladder (n = 9), and treatment changes (n = 8). Other causes include blood clots, mistaken normal anatomy, infectious/inflammatory changes, or had no cystoscopic correlate. Of 13 false negatives, 11 were due to technique, one to a large urinary residual, one to artifact. There were no errors in perception. CT urography is an accurate test for diagnosing bladder cancer; however, in protocols relying predominantly on excretory phase images, overall sensitivity remains insufficient to obviate cystoscopy. Awareness of bladder cancer mimics may reduce false-positive results. Improvements in CTU technique may reduce false-negative results.
BlackOPs: increasing confidence in variant detection through mappability filtering.
Cabanski, Christopher R; Wilkerson, Matthew D; Soloway, Matthew; Parker, Joel S; Liu, Jinze; Prins, Jan F; Marron, J S; Perou, Charles M; Hayes, D Neil
2013-10-01
Identifying variants using high-throughput sequencing data is currently a challenge because true biological variants can be indistinguishable from technical artifacts. One source of technical artifact results from incorrectly aligning experimentally observed sequences to their true genomic origin ('mismapping') and inferring differences in mismapped sequences to be true variants. We developed BlackOPs, an open-source tool that simulates experimental RNA-seq and DNA whole exome sequences derived from the reference genome, aligns these sequences by custom parameters, detects variants and outputs a blacklist of positions and alleles caused by mismapping. Blacklists contain thousands of artifact variants that are indistinguishable from true variants and, for a given sample, are expected to be almost completely false positives. We show that these blacklist positions are specific to the alignment algorithm and read length used, and BlackOPs allows users to generate a blacklist specific to their experimental setup. We queried the dbSNP and COSMIC variant databases and found numerous variants indistinguishable from mapping errors. We demonstrate how filtering against blacklist positions reduces the number of potential false variants using an RNA-seq glioblastoma cell line data set. In summary, accounting for mapping-caused variants tuned to experimental setups reduces false positives and, therefore, improves genome characterization by high-throughput sequencing.
van Turenhout, Sietze T; Oort, Frank A; Terhaar sive Droste, Jochim S; Coupé, Veerle M H; van der Hulst, Rene W; Loffeld, Ruud J; Scholten, Pieter; Depla, Annekatrien C T M; Bouman, Anneke A; Meijer, Gerrit A; Mulder, Chris J J; van Rossum, Leo G M
2012-07-01
Colorectal cancer screening by fecal immunochemical tests (FITs) is hampered by frequent false-positive (FP) results and thereby the risk of complications and strain on colonoscopy capacity. Hemorrhoids might be a plausible cause of FP results. To determine the contribution of hemorrhoids to the frequency of FP FIT results. Retrospective analysis from prospective cohort study. Five large teaching hospitals, including 1 academic hospital. All subjects scheduled for elective colonoscopy. FIT before bowel preparation. Frequency of FP FIT results in subjects with hemorrhoids as the only relevant abnormality compared with FP FIT results in subjects with no relevant abnormalities. Logistic regression analysis to determine colonic abnormalities influencing FP results. In 2855 patients, 434 had positive FIT results: 213 had advanced neoplasia and 221 had FP results. In 9 individuals (4.1%; 95% CI, 1.4-6.8) with an FP FIT result, hemorrhoids were the only abnormality. In univariate unadjusted analysis, subjects with hemorrhoids as the only abnormality did not have more positive results (9/134; 6.7%) compared with subjects without any abnormalities (43/886; 4.9%; P = .396). Logistic regression identified hemorrhoids, nonadvanced polyps, and a group of miscellaneous abnormalities, all significantly influencing false positivity. Of 1000 subjects with hemorrhoids, 67 would have FP results, of whom 18 would have FP results because of hemorrhoids only. Potential underreporting of hemorrhoids; high-risk individuals. Hemorrhoids in individuals participating in colorectal cancer screening will probably not lead to a substantial number of false-positive test results. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
False-positive cerebrospinal fluid cryptococcus antigen in Libman-Sacks endocarditis.
Isseh, Iyad N; Bourgi, Kassem; Nakhle, Asaad; Ali, Mahmoud; Zervos, Marcus J
2016-12-01
Cryptococcus meningoencephalitis is a serious opportunistic infection associated with high morbidity and mortality in immunocompromised hosts, particularly patients with advanced AIDS disease. The diagnosis is established through cerebrospinal fluid (CSF) cryptococcus antigen detection and cultures. Cryptococcus antigen testing is usually the initial test of choice due its high sensitivity and specificity along with the quick availability of the results. We hereby report a case of a false-positive CSF cryptococcus antigen assay in a patient with systemic lupus erythematosus presenting with acute confusion. While initial CSF evaluation revealed a positive cryptococcus antigen assay, the patient's symptoms were inconsistent with cryptococcus meningoencephalitis. A repeat CSF evaluation, done 3 days later, revealed a negative CSF cryptococcus antigen assay. Given the patient's active lupus disease and the elevated antinuclear antibody titers, we believe that the initial positive result was a false positive caused by interference from autoantibodies.
[Analysis for Discordance of Positive and Negative Blood Typing by Gel Card].
Li, Cui-Ying; Xu, Hong; Lei, Hui-Fen; Liu, Juan; Li, Xiao-Wei
2017-08-01
To explore the method of Gel card identifying ABO blood group, determine the inconsistent cause and the distribution of disease affecting factors, and put forward a method of its solutions. To collect 240 positive and negative typing-discordant blood speciments from patients examined by Gel card and send these speciments to blood type reference laboratory for examining with the classic tube method and serological test, such as salivary blood-group substance, in order to performe genotyping method when serologic test can not be determined. Among 240 positive and negative typing-discordant blood speciments from patients examined by Gel card, 107 blood speciments were positive and negative consistent examined by false agglutination test (44.58%), 133 blood specinents were discordent examined by false agglutination (55.42%), out of them, 35 cases (14.58%) with inconsistent cold agglutination test, 22 cases (9.17%) with weakened AB antigenicity, 16 cases (6.67%) with ABO subtyping, 12 cases (5.00%) with positive direct antiglobulin test, 11 cases (4.58%) with reduced or without antibodies, 11 cases (4.58%) with false aggregation caused by drugs or protein, 11 cases (4.58%) with salivary blood-type substances, 8 cases (3.33%) with non-ABO alloantibody, and 7 cases (2.92%) with allogeneic bone marrow transplantation. The distribution of disease were following: blood disease (16.83%), tumor (11.88%), and cardiopulmonary diseases (11.39%); chi-square test results indicated that the distribution significantly different. The analysis of ABO blood grouping shows a variety factors influencing positive and negative blood typing, and the Gel Card identification can produc more false positive blood types. Therefore, more attention should be paid on the high incidence diseases, such as blood disease, tumor, and cardiopulmonary disease.
Tests for a disease-susceptibility locus allowing for an inbreeding coefficient (F).
Song, Kijoung; Elston, Robert C
2003-11-01
We begin by discussing the false positive test results that arise because of cryptic relatedness and population substructure when testing a disease susceptibility locus. We extend and evaluate the Hardy-Weinberg disequilibrium (HWD) method, allowing for an inbreeding coefficient (F) in a similar way that Devlin and Roeder (1999) allowed for inbreeding in a case-control study. Then we compare the HWD measure and the common direct measure of linkage disequilibrium, both when there is no population substructure (F = 0) and when there is population substructure (F not = 0), for a single marker. The HWD test statistic gives rise to false positives caused by population stratification. These false positives can be controlled by adjusting the test statistic for the amount of variance inflation caused by the inbreeding coefficient (F). The power loss for the HWD test that arises when controlling for population structure is much less than that which arises for the common direct measure of linkage disequilibrium. However, in the multiplicative model, the HWD test has virtually no power even when allowing for non-zero F.
Steiner, J M; Rehfeld, J F; Pantchev, N
2010-01-01
An assay for the measurement of pancreatic elastase in dog feces has been introduced. The goal of this study was to evaluate the rate of false-positive fecal-elastase test results in dogs with suspected exocrine pancreatic insufficiency (EPI) and to assess serum cholecystokinin (CCK) concentrations in dogs with a false positive fecal elastase test result. Twenty-six fecal and serum samples from dogs suspected of EPI, for which samples had been submitted to a commercial laboratory (Vet Med Labor) for analysis. Prospective study. Serum trypsin-like immunoreactivity (TLI) was measured in 26 dogs with a decreased fecal elastase concentration of <10 microg/g feces. Serum CCK concentrations were measured in 21 of these dogs. Of 26 dogs with a decreased fecal elastase concentration, 6 (23%) had serum TLI concentrations within or above the reference range. Serum CCK concentrations were significantly higher in dogs with a true positive fecal elastase test result (median: 1.1 pmol/L; range: 0.1-3.3 pmol/L) than in those with a false positive fecal elastase test result (median: 0.1 pmol/L; range: 0.1-0.9 pmol/L; P value = .0163). The rate of false positive fecal elastase test results was high in this group of dogs, suggesting that diagnosis of EPI must be confirmed by other means. The decreased CCK concentration in dogs with a false positive fecal elastase test result could suggest that false positive results are because of decreased stimulation of exocrine pancreatic function caused by other conditions.
Is it time to sound an alarm about false-positive cell-free DNA testing for fetal aneuploidy?
Mennuti, Michael T; Cherry, Athena M; Morrissette, Jennifer J D; Dugoff, Lorraine
2013-11-01
Testing cell-free DNA (cfDNA) in maternal blood samples has been shown to have very high sensitivity for the detection of fetal aneuploidy with very low false-positive results in high-risk patients who undergo invasive prenatal diagnosis. Recent observation in clinical practice of several cases of positive cfDNA tests for trisomy 18 and trisomy 13, which were not confirmed by cytogenetic testing of the pregnancy, may reflect a limitation of the positive predictive value of this quantitative testing, particularly when it is used to detect rare aneuploidies. Analysis of a larger number of false-positive cases is needed to evaluate whether these observations reflect the positive predictive value that should be expected. Infrequently, mechanisms (such as low percentage mosaicism or confined placental mosaicism) might also lead to positive cfDNA testing that is not concordant with standard prenatal cytogenetic diagnosis. The need to explore these and other possible causes of false-positive cfDNA testing is exemplified by 2 of these cases. Additional evaluation of cfDNA testing in clinical practice and a mechanism for the systematic reporting of false-positive and false-negative cases will be important before this test is offered widely to the general population of low-risk obstetric patients. In the meantime, incorporating information about the positive predictive value in pretest counseling and in clinical laboratory reports is recommended. These experiences reinforce the importance of offering invasive testing to confirm cfDNA results before parental decision-making. Copyright © 2013 Mosby, Inc. All rights reserved.
Buton, Leckzinscka; Morel, Olivier; Gault, Patricia; Illouz, Frédéric; Rodien, Patrice; Rohmer, Vincent
2013-07-01
Iodine-131 (I-131) whole-body scan (WBS) plays an important role in the management of patients with differentiated thyroid carcinoma (DTC), to detect normal thyroid remnants and recurrent or metastatic disease. A focus of I-131 accumulation outside the thyroid bed and the areas of physiological uptake is strongly suggestive of a distant functioning metastasis. However, many false-positive I-131 WBS findings have been reported in the literature. We describe a series of 11 personal cases of patients with DTC, collected from 1992 to 2011, in whom diagnostic or post-treatment WBS showed false-positive retention of I-131 in various locations. False-positive accumulations of I-131 on WBS may be classified according to the underlying pathophysiological mechanisms: external and internal contaminations by body secretions, ectopic normal thyroid and gastric tissues, inflammatory and infectious diseases, benign and malignant tumors, cysts and effusions of serous cavities, thymic uptake, and other non classified causes. Clinicians must be aware of possible false-positive findings to avoid misinterpretations of the I-131 WBS, which could lead to inappropriate treatments. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Sandes, V S; Silva, S G C; Motta, I J F; Velarde, L G C; de Castilho, S R
2017-06-01
We propose to analyse the positive and false-positive results of treponemal and nontreponemal tests in blood donors from Brazil and to evaluate possible factors associated with the results of treponemal tests. Treponemal tests have been used widely for syphilis screening in blood banks. The introduction of these tests in donor screening has caused an impact and a loss of donors who need to be assessed. This was a retrospective cross-sectional study of syphilis screening and confirmatory test results of blood donors that were obtained before and after adopting a chemiluminescent immunoassay (CLIA). A comparative analysis was performed using a second sample drawn from positive donors. The possible factors associated with CLIA-positive or CLIA-false-positive results were investigated in a subgroup. Statistical tests were used to compare the proportions and adjusted estimates of association. The reactivity rate increased from 1·01% (N = 28 158) to 2·66% (N = 25 577) after introducing the new test. Among Venereal Disease Research Laboratory (VDRL)- and CLIA-confirmed results, the false-positive rates were 40·5% (N = 180) and 37·4% (N = 359), respectively (P = 0·5266). Older donors (OR = 1·04; P = 0·0010) and donors with lower education levels (OR = 6·59; P = 0·0029) were associated with a higher risk of positivity for syphilis. CLIA represents an improvement in blood bank serological screening. However, its use in a healthy population appears to result in high rates of false positives. Identifying which characteristics can predict false positives, however, remains a challenge. © 2017 British Blood Transfusion Society.
Samarakoon, Pubudu Saneth; Sorte, Hanne Sørmo; Stray-Pedersen, Asbjørg; Rødningen, Olaug Kristin; Rognes, Torbjørn; Lyle, Robert
2016-01-14
With advances in next generation sequencing technology and analysis methods, single nucleotide variants (SNVs) and indels can be detected with high sensitivity and specificity in exome sequencing data. Recent studies have demonstrated the ability to detect disease-causing copy number variants (CNVs) in exome sequencing data. However, exonic CNV prediction programs have shown high false positive CNV counts, which is the major limiting factor for the applicability of these programs in clinical studies. We have developed a tool (cnvScan) to improve the clinical utility of computational CNV prediction in exome data. cnvScan can accept input from any CNV prediction program. cnvScan consists of two steps: CNV screening and CNV annotation. CNV screening evaluates CNV prediction using quality scores and refines this using an in-house CNV database, which greatly reduces the false positive rate. The annotation step provides functionally and clinically relevant information using multiple source datasets. We assessed the performance of cnvScan on CNV predictions from five different prediction programs using 64 exomes from Primary Immunodeficiency (PIDD) patients, and identified PIDD-causing CNVs in three individuals from two different families. In summary, cnvScan reduces the time and effort required to detect disease-causing CNVs by reducing the false positive count and providing annotation. This improves the clinical utility of CNV detection in exome data.
Chen, X; Zhang, J; Feng, X; Chen, X; Yin, S; Wen, H; Zheng, S
2014-01-01
The patients with false immune diagnosis of hydatid disease were investigated for the humoural immune response to analyse the possible reasons and mechanism leading to false immune diagnosis. Two hundred and thirty-nine patients with nature-unknown cysts and 30 healthy controls were detected by immunological assays (four hydatid antigen-based immunogold filtration assay and enzyme-linked immune absorbent assay) and ultrasound. Sensitivity of and specificity of immunological assay and ultrasound were calculated, respectively. The serological diagnosis was compared with surgical pathology to screen the patients with false immune diagnosis for the immunoglobulin measurement and pathological analysis. The history and cyst characteristics were also reviewed. The results indicate the immunoglobulin has little influence on false immunodiagnosis. The false-negative immunodiagnosis was caused by the cysts' inactive status while the false positive caused by previous rupture, antigen cross-reaction. The clinical diagnosis of cystic echinococcosis requires a combination of immunodiagnosis and ultrasonography, which is the necessary complementary confirmation. PMID:24372157
Rheiner, Steven; Reichel, Derek; Rychahou, Piotr; Izumi, Tadahide; Yang, Hsin-Sheng; Bae, Younsoo
2017-08-07
Poly(ethylene glycol)-conjugated polyethylenimine (PEG-PEI) is a widely studied cationic polymer used to develop non-viral vectors for siRNA therapy of genetic disorders including cancer. Cell lines stably expressing luciferase reporter protein typically evaluate the transfection efficacy of siRNA/PEG-PEI complexes, however recent findings revealed that PEG-PEI can reduce luciferase expression independent of siRNA. This study elucidates a cause of the false positive effect in luciferase assays by using polymer nanoassemblies (PNAs) made from PEG, PEI, poly-(l-lysine) (PLL), palmitate (PAL), and deoxycholate (DOC): PEG-PEI (2P), PEG-PEI-PAL (3P), PEG-PLL (2P'), PEG-PLL-PAL (3P'), and PEG-PEI-DOC (2PD). In vitro transfection and western blot assays of luciferase using a colorectal cancer cell line expressing luciferase (HT29/LUC) concluded that 2P and 2P' caused no luciferase expression reduction while hydrophobically modified PNAs induced a 35-50% reduction (3P'<2PD<3P). Although cell viability remained stagnant, 3P triggered cellular stress responses including increased membrane porosity and decreased ATP and cellular protein concentrations. Raman spectroscopy suggested that hydrophobic groups influence PNA conformation changes, which may have caused over-ubiquitination and degradation of luciferase in the cells. These results indicate that hydrophobically modified PEG-PEI induces cellular distress causing over-ubiquitination of the luciferase protein, producing false positive siRNA transfection in the luciferase assay. Copyright © 2017 Elsevier B.V. All rights reserved.
The local lymph node assay being too sensitive?
Hans-Werner, Vohr; Jürgen, Ahr Hans
2005-12-01
The local lymph node assay (LLNA) and modifications thereof were recently recognized by the OECD as stand-alone methods for the detection of skin-sensitizing potential. However, although the validity of the LLNA was acknowledged by the ICCVAM, attention was drawn to one major problem, i.e., the possibility of false positive results caused by non-specific cell activation as a result of inflammatory processes in the skin (irritation). This is based on the fact that inflammatory processes in the skin may lead to non-specific activation of dendritic cells, cell migration and non-specific proliferation of lymph node cells. Measuring cell proliferation by radioactive or non-radioactive methods, without taking the irritating properties of test items into account, leads thus to false positive reactions. In this paper, we have compared both endpoints: (1) cell proliferation alone and (2) cell proliferation in combination with inflammatory (irritating) processes. It turned out that a considerable number of tests were "false positive" to the definition mentioned above. By excluding such false positive results the LLNA seems not to be more sensitive than relevant guinea pig assays. These various methods and results are described here.
Larsen, W G
1985-01-01
The most common reaction to fragrance materials seen by practicing dermatologists is allergic contact dermatitis. Photodermatitis is occasionally seen, as is contact urticaria, irritation, and depigmentation. Fragrances are the leading cause of allergic contact dermatitis due to cosmetics. The fragrance mixture can cause false-positive reactions; therefore, it is more desirable to test with a separate series of fragrance materials.
... into (contaminating) the blood sample and causing a false-positive result (see below). The sample is sent to a laboratory. There, it is placed in a special dish (culture). It is then watched to see if bacteria ...
Lee, Jae Seok; Kim, Eui-Chong; Joo, Sei Ick; Lee, Sang-Min; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Shim, Young-Soo; Yim, Jae-Joon
2008-10-01
Although it is not rare to find sputum that is positive acid-fast bacilli (AFB) smear but subsequent culture fails to isolate mycobacteria in clinical practice, the incidence and clinical implication of those sputa from new patients has not been clearly elucidated. The aim of this study was to determine the incidence and clinical implication of sputum with positive AFB smear but negative in mycobacterial culture. All sputa that were positive AFB smear requested during diagnostic work up for new patients visiting Seoul National University Hospital from 1 January 2005 through 31 December 2006 were included. Sputa producing a positive AFB smear but negative mycobacterial culture were classified into one of four categories: laboratory failure to isolate mycobacteria, false positive AFB smear, pathogen may show a positive AFB smear other than mycobacteria, and indeterminate results. Out of 447 sputa with a positive AFB smear, 29 (6.5%) failed to culture any organism. Among these 29 sputa, 18 were caused by laboratory failure to isolate mycobacteria, six were false positive smears, and five indeterminate. Although most sputum with a positive AFB smear but negative culture could be classified as a laboratory failure, clinicians should consider the possibility of false positive AFB smear.
Bergougnoux, Anne; Boureau-Wirth, Amandine; Rouzier, Cécile; Altieri, Jean-Pierre; Verneau, Fanny; Larrieu, Lise; Koenig, Michel; Claustres, Mireille; Raynal, Caroline
2016-05-01
The detection of two frequent CFTR disease-causing variations in the context of a newborn screening program (NBS) usually leads to the diagnosis of cystic fibrosis (CF) and a relevant genetic counseling in the family. In the present study, CF-causing variants p.Phe508del (F508del) and c.3140-26A>G (3272-26A>G) were identified on a neonate with positive ImmunoReactive Trypsinogen test by the Elucigene™ CF30 kit. The CF diagnosis initially suggested, despite three inconclusive Sweat Chloride Tests (SCT), was finally ruled out after the familial segregation study combined with a negative SCT. Haplotype studies, based on the comparison of 80 p.Phe508del haplotypes, suggested a probable de novo occurrence of c.3140-26A>G on the p.Phe508del ancestral allele in this family. This false positive case emphasizes the importance of SCT in the NBS strategy. Moreover, it raises the need for familial segregation studies in CF and in overall molecular diagnosis strategy of autosomal recessive diseases. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Missed Lesions at CT Colonography: Lessons Learned
Pickhardt, Perry J.
2017-01-01
Misinterpretation at CT colonography (CTC) can result in either a colorectal lesion being missed (false negative) or a false-positive diagnosis. This review will largely focus on potential missed lesions – and ways to avoid such misses. The general causes of false-negative interpretation at CTC can be broadly characterized and grouped into discrete categories related to suboptimal study technique, specific lesion characteristics, anatomic location, and imaging artifacts. Overlapping causes further increase the likelihood of missing a clinically relevant lesion. In the end, if the technical factors of bowel preparation, colonic distention, and robust CTC software are adequately addressed on a consistent basis, and the reader is aware of all the potential pitfalls at CTC, important lesions will seldom be missed. PMID:22539045
Navabi, Nazlee; Montebatsi, Milton; Scott, Michelle; Gluckman, Stephen J; Reid, Michael J A
2015-01-01
A case of false-negative serum latex agglutination cryptococcal antigen (CRAG) test in a 45-year-old HIV-positive male with Cryptococcus-positive culture is described. The patient was presented to a hospital in Botswana, with breathlessness and a diffuse papular rash. His CD4 count was 25 cells/μL. Despite the suspicion for disseminated cryptococcal disease, an initial serum CRAG latex test was negative. Results of subsequent Indian ink staining, culture of cerebrospinal fluid and skin scrapings, and serum lateral flow immunoassay (LFA) were all positive for Cryptococcus neoformans. There are several possible explanations for the false-negative CRAG latex test. Given the positive LFA result, we speculate that disease may have been caused by Cryptococcus gattii, which is estimated to be responsible for between 15% and 30% of all cryptococcal diseases in Botswana. Reduced sensitivity of CRAG latex assays for detecting C gattii may lead to underdiagnosis of cryptococcal infection. © The Author(s) 2014.
Diagnosing periprosthetic infection: false-positive intraoperative Gram stains.
Oethinger, Margret; Warner, Debra K; Schindler, Susan A; Kobayashi, Hideo; Bauer, Thomas W
2011-04-01
Intraoperative Gram stains have a reported low sensitivity but high specificity when used to help diagnose periprosthetic infections. In early 2008, we recognized an unexpectedly high frequency of apparent false-positive Gram stains from revision arthroplasties. The purpose of this report is to describe the cause of these false-positive test results. We calculated the sensitivity and specificity of all intraoperative Gram stains submitted from revision arthroplasty cases during a 3-month interval using microbiologic cultures of the same samples as the gold standard. Methods of specimen harvesting, handling, transport, distribution, specimen processing including tissue grinding/macerating, Gram staining, and interpretation were studied. After a test modification, results of specimens were prospectively collected for a second 3-month interval, and the sensitivity and specificity of intraoperative Gram stains were calculated. The retrospective review of 269 Gram stains submitted from revision arthroplasties indicated historic sensitivity and specificity values of 23% and 92%, respectively. Systematic analysis of all steps of the procedure identified Gram-stained but nonviable bacteria in commercial broth reagents used as diluents for maceration of periprosthetic membranes before Gram staining and culture. Polymerase chain reaction and sequencing showed mixed bacterial DNA. Evaluation of 390 specimens after initiating standardized Millipore filtering of diluent fluid revealed a reduced number of positive Gram stains, yielding 9% sensitivity and 99% specificity. Clusters of false-positive Gram stains have been reported in other clinical conditions. They are apparently rare related to diagnosing periprosthetic infections but have severe consequences if used to guide treatment. Even occasional false-positive Gram stains should prompt review of laboratory methods. Our observations implicate dead bacteria in microbiologic reagents as potential sources of false-positive Gram stains.
Ranitidine interference with standard amphetamine immunoassay.
Liu, Li; Wheeler, Sarah E; Rymer, Jacqueline A; Lower, Darla; Zona, Jayne; Peck Palmer, Octavia M; Tamama, Kenichi
2015-01-01
We recently encountered several cases of possible false positive results of amphetamine on the Beckman Coulter AMPH assay, but not on the Siemens EMIT II Plus assay. Our clinical chart review suggested that ranitidine interference may be responsible for the false positive results of the AMPH assays. Blank urine specimens spiked with ranitidine concentrations ranging from 5μg/ml to 5mg/ml were analyzed on both the AMPH and EMIT II Plus assays. To examine if the false positive results were due to assay specific reagent/sample ratios, we prepared 3 different sample to reagent ratios and analyzed them for amphetamine reaction rates on both assays. Ranitidine at 160μg/ml caused a positive interference on the AMPH assay. No interference was observed by ranitidine on the EMIT II Plus assay. Specifically, the sample to reagent ratios tested neither eliminated the positive inference on the AMP assay nor introduced an interference on the EMIT II Plus assay. Unlike the EMIT II Plus assay, the AMPH assay has cross-activity with ranitidine, which is independent of sample to reagent ratio. Copyright © 2014 Elsevier B.V. All rights reserved.
Prevention. How much harm? How much benefit? 3. Physical, psychological and social harm.
Marshall, K G
1996-01-01
Harm caused by preventive programs may be physical, psychological, social or, if informed consent has not been obtained, ethical. Adverse effects of preventive screening programs may occur at any of the three levels of the "screening cascade", the screening procedure itself, the investigation of abnormal results of screening tests or the treatment of detected abnormalities or diseases. The greatest harm occurs at the second and third levels. Examples of procedures that may cause physical harm are venipuncture, mammography, colonoscopy, breast biopsy, transrectal ultrasonography, prostate biopsy, weight-reducing and cholesterol-lowering diets and radical prostatectomy. The psychological and social harm of preventive programs involves anticipated discomfort or perception of adverse effects of preventive interventions; unpleasant interactions with health care workers, time required for preventive programs, excessive overall awareness of health, anxiety over the results of a screening test implications of a positive screening test, consequences of being labelled as "sick" or "at risk," psychopathologic effects induced directly by preventive programs and, in the case of a false-negative test result, false assurance of disease-free status. Since the positive predictive value of screening tests in the general population is always low, most abnormal test results are "false-positive," these engender a great deal of psychological discuss among patients. PMID:8800074
Koita, Ousmane A; Doumbo, Ogobara K; Ouattara, Amed; Tall, Lalla K; Konaré, Aoua; Diakité, Mahamadou; Diallo, Mouctar; Sagara, Issaka; Masinde, Godfred L; Doumbo, Safiatou N; Dolo, Amagana; Tounkara, Anatole; Traoré, Issa; Krogstad, Donald J
2012-02-01
We identified 480 persons with positive thick smears for asexual Plasmodium falciparum parasites, of whom 454 had positive rapid diagnostic tests (RDTs) for the histidine-rich protein 2 (HRP2) product of the hrp2 gene and 26 had negative tests. Polymerase chain reaction (PCR) amplification for the histidine-rich repeat region of that gene was negative in one-half (10/22) of false-negative specimens available, consistent with spontaneous deletion. False-negative RDTs were found only in persons with asymptomatic infections, and multiplicities of infection (MOIs) were lower in persons with false-negative RDTs (both P < 0.001). These results show that parasites that fail to produce HRP2 can cause patent bloodstream infections and false-negative RDT results. The importance of these observations is likely to increase as malaria control improves, because lower MOIs are associated with false-negative RDTs and false-negative RDTs are more frequent in persons with asymptomatic infections. These findings suggest that the use of HRP2-based RDTs should be reconsidered.
Influence of ECG measurement accuracy on ECG diagnostic statements.
Zywietz, C; Celikag, D; Joseph, G
1996-01-01
Computer analysis of electrocardiograms (ECGs) provides a large amount of ECG measurement data, which may be used for diagnostic classification and storage in ECG databases. Until now, neither error limits for ECG measurements have been specified nor has their influence on diagnostic statements been systematically investigated. An analytical method is presented to estimate the influence of measurement errors on the accuracy of diagnostic ECG statements. Systematic (offset) errors will usually result in an increase of false positive or false negative statements since they cause a shift of the working point on the receiver operating characteristics curve. Measurement error dispersion broadens the distribution function of discriminative measurement parameters and, therefore, usually increases the overlap between discriminative parameters. This results in a flattening of the receiver operating characteristics curve and an increase of false positive and false negative classifications. The method developed has been applied to ECG conduction defect diagnoses by using the proposed International Electrotechnical Commission's interval measurement tolerance limits. These limits appear too large because more than 30% of false positive atrial conduction defect statements and 10-18% of false intraventricular conduction defect statements could be expected due to tolerated measurement errors. To assure long-term usability of ECG measurement databases, it is recommended that systems provide its error tolerance limits obtained on a defined test set.
McClintock, Brett T.; Bailey, Larissa L.; Pollock, Kenneth H.; Simons, Theodore R.
2010-01-01
The recent surge in the development and application of species occurrence models has been associated with an acknowledgment among ecologists that species are detected imperfectly due to observation error. Standard models now allow unbiased estimation of occupancy probability when false negative detections occur, but this is conditional on no false positive detections and sufficient incorporation of explanatory variables for the false negative detection process. These assumptions are likely reasonable in many circumstances, but there is mounting evidence that false positive errors and detection probability heterogeneity may be much more prevalent in studies relying on auditory cues for species detection (e.g., songbird or calling amphibian surveys). We used field survey data from a simulated calling anuran system of known occupancy state to investigate the biases induced by these errors in dynamic models of species occurrence. Despite the participation of expert observers in simplified field conditions, both false positive errors and site detection probability heterogeneity were extensive for most species in the survey. We found that even low levels of false positive errors, constituting as little as 1% of all detections, can cause severe overestimation of site occupancy, colonization, and local extinction probabilities. Further, unmodeled detection probability heterogeneity induced substantial underestimation of occupancy and overestimation of colonization and local extinction probabilities. Completely spurious relationships between species occurrence and explanatory variables were also found. Such misleading inferences would likely have deleterious implications for conservation and management programs. We contend that all forms of observation error, including false positive errors and heterogeneous detection probabilities, must be incorporated into the estimation framework to facilitate reliable inferences about occupancy and its associated vital rate parameters.
Evaluation of Epstein-Barr Virus infection in hypopharyngeal carcinomas from 37 Japanese patients.
Zhou, L; Miyagi, Y; Hiroshi, E; Tanaka, Y; Aoki, I; Tsukuda, M
1998-06-01
Thirty-seven biopsy specimens from primary sites, 18 surgically removed metastatic neck nodes, and 18 surgically removed primary sites from 37 patients with hypopharyngeal carcinoma (HPC) were evaluated for the presence of Epstein-Barr Virus (EBV) infection by in situ hybridization (ISH) and polymerase chain reaction (PCR). Although some of normal lymphocytes in 6 of 18 metastatic nodes were positive by ISH, there were no positive results from HPC tumor cells themselves. Our results indicate that EBV-infected non-neoplastic cells such as lymphocytes can be a cause of false positivity, if a study were conducted with PCR alone. Because ISH for EBV-encoded early RNAs was highly sensitive, even more sensitive than PCR from paraffin-embedded samples in our study, this method should be the first choice for identification of EBV infection to avoid false positives.
Center not liable for defamation from false-positive hepatitis test.
1997-04-18
The Nebraska Court of Appeals ruled that [name removed] does not have a cause of action against the Lincoln Plasma Center in Lincoln, NE. The center blacklisted him as a carrier of hepatitis B virus; subsequent tests proved [name removed] was uninfected. [Name removed], a paid plasma donator, was placed on an ineligible list after he tested positive for the hepatitis B surface antigen. [Name removed] sued, alleging that Lincoln defamed him by publishing false information to blood banks about his eligibility to donate. The Court of Appeals upheld a trial court's directed verdict because there was no evidence that the plasma center acted in malice.
Thyroid Fine-Needle Aspiration Cytology:Causes of false-positive results.
Malheiros, Daniela C; Canberk, Sule; Poller, David N; Schmitt, Fernando
2018-05-16
In this paper, we aim to focus on false positive results in the evaluation of thyroid aspirations, covering cystic, inflammatory, follicular and oncocytic lesions, papillary carcinoma, and medullary carcinoma of thyroid. The recently described entity, "noninvasive follicular thyroid neoplasm with papillary-like nuclear features" (NIFTP), is also discussed detailing the impact of its introduction on the sensitivity and specificity of thyroid FNA, as well as the use of molecular tests for diagnostics. Medicolegal issues in relation to current practice in English law are also described. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Reducing False Positives in Runtime Analysis of Deadlocks
NASA Technical Reports Server (NTRS)
Bensalem, Saddek; Havelund, Klaus; Clancy, Daniel (Technical Monitor)
2002-01-01
This paper presents an improvement of a standard algorithm for detecting dead-lock potentials in multi-threaded programs, in that it reduces the number of false positives. The standard algorithm works as follows. The multi-threaded program under observation is executed, while lock and unlock events are observed. A graph of locks is built, with edges between locks symbolizing locking orders. Any cycle in the graph signifies a potential for a deadlock. The typical standard example is the group of dining philosophers sharing forks. The algorithm is interesting because it can catch deadlock potentials even though no deadlocks occur in the examined trace, and at the same time it scales very well in contrast t o more formal approaches to deadlock detection. The algorithm, however, can yield false positives (as well as false negatives). The extension of the algorithm described in this paper reduces the amount of false positives for three particular cases: when a gate lock protects a cycle, when a single thread introduces a cycle, and when the code segments in different threads that cause the cycle can actually not execute in parallel. The paper formalizes a theory for dynamic deadlock detection and compares it to model checking and static analysis techniques. It furthermore describes an implementation for analyzing Java programs and its application to two case studies: a planetary rover and a space craft altitude control system.
Gatton, Michelle L; Ciketic, Sadmir; Barnwell, John W; Cheng, Qin; Chiodini, Peter L; Incardona, Sandra; Bell, David; Cunningham, Jane; González, Iveth J
2018-01-01
Malaria rapid diagnostic tests (RDTs) can produce false positive (FP) results in patients with human African trypanosomiasis and rheumatoid factor (RF), but specificity against other infectious agents and immunological factors is largely unknown. Low diagnostic specificity caused by cross-reactivity may lead to over-estimates of the number of malaria cases and over-use of antimalarial drugs, at the cost of not diagnosing and treating the true underlying condition. Data from the WHO Malaria RDT Product Testing Programme was analysed to assess FP rates of 221 RDTs against four infectious agents (Chagas, dengue, Leishmaniasis and Schistosomiasis) and four immunological factors (anti-nuclear antibody, human anti-mouse antibody (HAMA), RF and rapid plasma regain). Only RDTs with a FP rate against clean negative samples less than 10% were included. Paired t-tests were used to compare product-specific FP rates on clean negative samples and samples containing non-Plasmodium infectious agents and immunological factors. Forty (18%) RDTs showed no FP results against any tested infectious agent or immunological factor. In the remaining RDTs significant and clinically relevant increases in FP rates were observed for samples containing HAMA and RF (P<0.001). There were significant correlations between product-matched FP rates for RF and HAMA on all RDT test bands (P<0.001), and FP rates for each infectious agent and immunological factor were also correlated between test bands of combination RDTs (P≤0.002). False positive results against non-Plasmodium infectious agents and immunological factors does not appear to be a universal property of malaria RDTs. However, since many malaria RDTs have elevated FP rates against HAMA and RF positive samples practitioners may need to consider the possibility of false positive results for malaria in patients with conditions that stimulate HAMA or RF.
CHROMOSPHERIC EMISSION OF PLANET CANDIDATE HOST STARS: A WAY TO IDENTIFY FALSE POSITIVES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karoff, Christoffer; Knudsen, Mads Faurschou; Albrecht, Simon
2016-10-10
It has been hypothesized that the presence of closely orbiting giant planets is associated with enhanced chromospheric emission of their host stars. The main cause for such a relation would likely be enhanced dynamo action induced by the planet. We present measurements of chromospheric emission in 234 planet candidate systems from the Kepler mission. This ensemble includes 37 systems with giant-planet candidates, which show a clear emission enhancement. The enhancement, however, disappears when systems that are also identified as eclipsing binary candidates are removed from the ensemble. This suggests that a large fraction of the giant-planet candidate systems with chromosphericmore » emission stronger than the Sun are not giant-planet systems, but false positives. Such false-positive systems could be tidally interacting binaries with strong chromospheric emission. This hypothesis is supported by an analysis of 188 eclipsing binary candidates that show increasing chromospheric emission as function of decreasing orbital period.« less
Emotionally negative pictures enhance gist memory.
Bookbinder, S H; Brainerd, C J
2017-02-01
In prior work on how true and false memory are influenced by emotion, valence and arousal have often been conflated. Thus, it is difficult to say which specific effects are caused by valence and which are caused by arousal. In the present research, we used a picture-memory paradigm that allowed emotional valence to be manipulated with arousal held constant. Negatively valenced pictures elevated both true and false memory, relative to positive and neutral pictures. Conjoint recognition modeling revealed that negative valence (a) reduced erroneous suppression of true memories and (b) increased the familiarity of the semantic content of both true and false memories. Overall, negative valence impaired the verbatim side of episodic memory but enhanced the gist side, and these effects persisted even after a week-long delay. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Marin, Stephanie J; Doyle, Kelly; Chang, Annie; Concheiro-Guisan, Marta; Huestis, Marilyn A; Johnson-Davis, Kamisha L
2016-01-01
Some amphetamine (AMP) and ecstacy (MDMA) urine immunoassay (IA) kits are prone to false-positive results due to poor specificity of the antibody. We employed two techniques, high-resolution mass spectrometry (HRMS) and an in silico structure search, to identify compounds likely to cause false-positive results. Hundred false-positive IA specimens for AMP and/or MDMA were analyzed by an Agilent 6230 time-of-flight (TOF) mass spectrometer. Separately, SciFinder (Chemical Abstracts) was used as an in silico structure search to generate a library of compounds that are known to cross-react with AMP/MDMA IAs. Chemical formulas and exact masses of 145 structures were then compared against masses identified by TOF. Compounds known to have cross-reactivity with the IAs were identified in the structure-based search. The chemical formulas and exact masses of 145 structures (of 20 chemical formulas) were compared against masses identified by TOF. Urine analysis by HRMS correlates accurate mass with chemical formulae, but provides little information regarding compound structure. Structural data of targeted antigens can be utilized to correlate HRMS-derived chemical formulas with structural analogs. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Buffer substitution in malaria rapid diagnostic tests causes false-positive results
2010-01-01
Background Malaria rapid diagnostic tests (RDTs) are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution) or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands) showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74%) RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20), and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs). Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness) of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results. PMID:20650003
Cross-Reactivity of Pantoprazole with Three Commercial Cannabinoids Immunoassays in Urine.
Gomila, Isabel; Barceló, Bernardino; Rosell, Antonio; Avella, Sonia; Sahuquillo, Laura; Dastis, Macarena
2017-11-01
Pantoprazole is a frequently prescribed proton pump inhibitor (PPI) commonly utilized in the management of gastrointestinal symptoms. Few substances have proved to cause a false-positive cannabinoid urine screen. However, a case of false-positive urine cannabinoid screen in a patient who received a pantoprazole dose has been recently published. The purpose of this study was to determine the potential cross-reactivity of pantoprazole in the cannabinoid immunoassays: Alere Triage® TOX Drug Screen, KIMS® Cannabinoids II and DRI® Cannabinoids Assay. Drug-free urine to which pantoprazole was added up to 12,000 μg/mL produced negative results in the DRI® Cannabinoids and KIMS® Cannabinoids II. Alere Triage® TOX Drug Screen assay gave positive results at pantoprazole concentrations higher than 1,000 μg/mL. Urine samples from 8 pediatric patients were collected at the beginning of their pantoprazole treatment. Alere Triage® TOX Drug Screen assay produced positive test results in all patient samples and KIMS® Cannabinoids II immunoassay produced positive test results in one patient sample. None patient sample gave a false-positive result when analyzed by the DRI® Cannabinoids Assay. Our findings demonstrate that some cannabinoids immunoassays are susceptible to cross-reaction errors resulting from the presence in urine of pantoprazole and the resulting metabolism of the parent drug. Clinicians should be aware of the possibility of false-positive results for cannabinoids after a pantoprazole treatment. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Impact of false-negative sentinel lymph node biopsy on survival in patients with cutaneous melanoma.
Caracò, C; Marone, U; Celentano, E; Botti, G; Mozzillo, N
2007-09-01
Sentinel lymph node biopsy is widely accepted as standard care in melanoma despite lack of pertinent randomized trials results. A possible pitfall of this procedure is the inaccurate identification of the sentinel lymph node leading to biopsy and analysis of a nonsentinel node. Such a technical failure may yield a different prognosis. The purpose of this study is to analyze the incidence of false negativity and its impact on clinical outcome and to try to understand its causes. The Melanoma Data Base at National Cancer Institute of Naples was analyzed comparing results between false-negative and tumor-positive sentinel node patients focusing on overall survival and prognostic factors influencing the clinical outcome. One hundred fifty-one cases were diagnosed to be tumor-positive after sentinel lymph node biopsy and were subjected to complete lymph node dissection. Thirty-four (18.4%)patients with tumor-negative sentinel node subsequently developed lymph node metastases in the basin site of the sentinel procedure. With a median follow-up of 42.8 months the 5-year overall survival was 48.4% and 66.3% for false-negative and tumor-positive group respectively with significant statistical differences (P < .03). The sensitivity of sentinel lymph node biopsy was 81.6%, and a regional nodal basin recurrence after negative-sentinel node biopsy means a worse prognosis, compared with patients submitted to complete lymph node dissection after a positive sentinel biopsy. The evidence of higher number of tumor-positive nodes after delayed lymphadenectomy in false-negative group compared with tumor-positive sentinel node cases, confirmed the importance of an early staging of lymph nodal involvement. Further data will better clarify the role of prognostic factors to identify cases with a more aggressive biological behavior of the disease.
Costa, Elisa; Tormo, Nuria; Clari, María Ángeles; Bravo, Dayana; Muñoz-Cobo, Beatriz; Navarro, David
2009-01-01
Acute parvovirus B19 infection has been reported to cause false-positive results frequently in the Epstein-Barr (EBV) and herpes simplex virus (HSV) immunoglobulin M (IgM) assays from DiaSorin performed on the Liaison platform. We tested 65 sera from patients with a presumptive or conclusive diagnosis of acute parvovirus B19 infection in both assays and obtained no false-positive results in the EBV IgM test and 10.4% nonspecific reactivities in the HSV IgM assay. Our data support the specificity of both assays in this clinical setting. PMID:19571110
False positive indium-111 white blood cell scan in a closed clavicle fracture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Friedman, R.J.; Gordon, L.
1988-01-01
Aggressive treatment of the multiply injured patient often requires early fixation of many fractures, some of which may be open. Often, patients develop postoperative fevers requiring a thorough workup to rule out infection. Recently, indium-111 white blood cell (WBC) imaging has become a valuable adjunct in the diagnosis of acute infection. The patient described had a simple, closed clavicle fracture with markedly increased activity on an indium-111 WBC scan obtained for fever workup. This subsequently proved to be a normal, healing, noninfected fracture by other diagnostic techniques. Noninfected, simple closed fractures should be added to the list of causes formore » a false-positive indium-111 WBC scan.« less
[A pseudo-outbreak of pharyngeal gonorrhoea related to a false-positive PCR-result].
Verzijl, A; Berretty, P J M; Erceg, A; Krekels, G A M; Van den Brule, A J C; Boel, C H E
2007-03-24
Nucleic acid amplification tests, including the polymerase chain reaction (PCR), are sensitive and specific tests that are often used for diagnosing sexually transmitted diseases (STDs). A pseudo-outbreak of pharyngeal gonorrhoea in a group of prostitutes turned out to have been caused by false-positive test results due to commensal oropharyngeal Neisseria species. Specific molecular tests may yield erroneous results. When the results of an STD study have major consequences at a legal or social level, it is advisable, in consultation with a medical microbiologist, to take a sample for culture or to carry out a second molecular test aimed at a different part of the bacterial genome.
MicroRNA array normalization: an evaluation using a randomized dataset as the benchmark.
Qin, Li-Xuan; Zhou, Qin
2014-01-01
MicroRNA arrays possess a number of unique data features that challenge the assumption key to many normalization methods. We assessed the performance of existing normalization methods using two microRNA array datasets derived from the same set of tumor samples: one dataset was generated using a blocked randomization design when assigning arrays to samples and hence was free of confounding array effects; the second dataset was generated without blocking or randomization and exhibited array effects. The randomized dataset was assessed for differential expression between two tumor groups and treated as the benchmark. The non-randomized dataset was assessed for differential expression after normalization and compared against the benchmark. Normalization improved the true positive rate significantly in the non-randomized data but still possessed a false discovery rate as high as 50%. Adding a batch adjustment step before normalization further reduced the number of false positive markers while maintaining a similar number of true positive markers, which resulted in a false discovery rate of 32% to 48%, depending on the specific normalization method. We concluded the paper with some insights on possible causes of false discoveries to shed light on how to improve normalization for microRNA arrays.
MicroRNA Array Normalization: An Evaluation Using a Randomized Dataset as the Benchmark
Qin, Li-Xuan; Zhou, Qin
2014-01-01
MicroRNA arrays possess a number of unique data features that challenge the assumption key to many normalization methods. We assessed the performance of existing normalization methods using two microRNA array datasets derived from the same set of tumor samples: one dataset was generated using a blocked randomization design when assigning arrays to samples and hence was free of confounding array effects; the second dataset was generated without blocking or randomization and exhibited array effects. The randomized dataset was assessed for differential expression between two tumor groups and treated as the benchmark. The non-randomized dataset was assessed for differential expression after normalization and compared against the benchmark. Normalization improved the true positive rate significantly in the non-randomized data but still possessed a false discovery rate as high as 50%. Adding a batch adjustment step before normalization further reduced the number of false positive markers while maintaining a similar number of true positive markers, which resulted in a false discovery rate of 32% to 48%, depending on the specific normalization method. We concluded the paper with some insights on possible causes of false discoveries to shed light on how to improve normalization for microRNA arrays. PMID:24905456
False positives in Biolog EcoPlates™ and MT2 MicroPlates™ caused by calcium.
Pierce, Melissa L; Ward, J Evan; Dobbs, Fred C
2014-02-01
Biolog MicroPlates(TM) (e.g. EcoPlate(TM), MT2 MicroPlate(TM), GN MicroPlate(TM)) are useful tools for characterizing microbial communities, providing community-level physiological profiles to terrestrial and aquatic ecologists. The more recently designed Biolog EcoPlates have been used frequently in aquatic ecology with success. This study, however, reveals one major problem when using EcoPlates to evaluate samples within an estuarine or seawater matrix. At concentrations greater than 100 parts per million, the cation calcium begins to interfere with the microplate chemistry, causing false positive readings. Experiments, in which multiple treatments of natural and artificial seawater were tested, as well as calcium-addition experiments, demonstrate that calcium inhibits complete dissolution of the minimal growth medium in wells. Future studies involving Biolog EcoPlates and MicroPlates should take this effect into account, and the dilution of samples is strongly recommended to diminish the "calcium effect." Copyright © 2013 Elsevier B.V. All rights reserved.
False-Positive Rate of AKI Using Consensus Creatinine-Based Criteria.
Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G S; Negoianu, Dan; Testani, Jeffrey M; Berns, Jeffrey S; Parikh, Chirag R; Wilson, F Perry
2015-10-07
Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false-positive rates because of inherent laboratory and biologic variabilities of creatinine. We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false-positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient's true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false-positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%-8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false-positive AKI diagnosis rate of 30.5% (interquartile range =30.1%-30.9%) versus 2.0% (interquartile range =1.9%-2.1%) in patients with true serum creatinine values <1.5 mg/dl (P<0.001). Use of small serum creatinine changes to diagnose AKI is limited by high false-positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. Copyright © 2015 by the American Society of Nephrology.
Zardo, Pauline; Graves, Nicholas
2018-01-01
The “publish or perish” incentive drives many researchers to increase the quantity of their papers at the cost of quality. Lowering quality increases the number of false positive errors which is a key cause of the reproducibility crisis. We adapted a previously published simulation of the research world where labs that produce many papers are more likely to have “child” labs that inherit their characteristics. This selection creates a competitive spiral that favours quantity over quality. To try to halt the competitive spiral we added random audits that could detect and remove labs with a high proportion of false positives, and also improved the behaviour of “child” and “parent” labs who increased their effort and so lowered their probability of making a false positive error. Without auditing, only 0.2% of simulations did not experience the competitive spiral, defined by a convergence to the highest possible false positive probability. Auditing 1.35% of papers avoided the competitive spiral in 71% of simulations, and auditing 1.94% of papers in 95% of simulations. Audits worked best when they were only applied to established labs with 50 or more papers compared with labs with 25 or more papers. Adding a ±20% random error to the number of false positives to simulate peer reviewer error did not reduce the audits’ efficacy. The main benefit of the audits was via the increase in effort in “child” and “parent” labs. Audits improved the literature by reducing the number of false positives from 30.2 per 100 papers to 12.3 per 100 papers. Auditing 1.94% of papers would cost an estimated $15.9 million per year if applied to papers produced by National Institutes of Health funding. Our simulation greatly simplifies the research world and there are many unanswered questions about if and how audits would work that can only be addressed by a trial of an audit. PMID:29649314
Barnett, Adrian G; Zardo, Pauline; Graves, Nicholas
2018-01-01
The "publish or perish" incentive drives many researchers to increase the quantity of their papers at the cost of quality. Lowering quality increases the number of false positive errors which is a key cause of the reproducibility crisis. We adapted a previously published simulation of the research world where labs that produce many papers are more likely to have "child" labs that inherit their characteristics. This selection creates a competitive spiral that favours quantity over quality. To try to halt the competitive spiral we added random audits that could detect and remove labs with a high proportion of false positives, and also improved the behaviour of "child" and "parent" labs who increased their effort and so lowered their probability of making a false positive error. Without auditing, only 0.2% of simulations did not experience the competitive spiral, defined by a convergence to the highest possible false positive probability. Auditing 1.35% of papers avoided the competitive spiral in 71% of simulations, and auditing 1.94% of papers in 95% of simulations. Audits worked best when they were only applied to established labs with 50 or more papers compared with labs with 25 or more papers. Adding a ±20% random error to the number of false positives to simulate peer reviewer error did not reduce the audits' efficacy. The main benefit of the audits was via the increase in effort in "child" and "parent" labs. Audits improved the literature by reducing the number of false positives from 30.2 per 100 papers to 12.3 per 100 papers. Auditing 1.94% of papers would cost an estimated $15.9 million per year if applied to papers produced by National Institutes of Health funding. Our simulation greatly simplifies the research world and there are many unanswered questions about if and how audits would work that can only be addressed by a trial of an audit.
Anecdotal reports suggest that high environmental or occupational exposures to the fuel oxygenate methyl tert-butyl ether (MTBE) may result in breath concentrations that are sufficiently elevated to cause a false positive on commercial breath-alcohol analyzers. We evaluated th...
Report of data on children with non-typhi Salmonella gastroenteritis in a three-year period.
Küçük, Öznur; Biçer, Suat; Ugraş, Meltem; Çöl, Defne; Giray, Tuba; Çiler Erdag, Gülay; Gürol, Yeşim; Yilmaz, Gülden; Yalvaç, Zerrin; Vitrinel, Ayça; Kaspar, Çigdem
2016-09-01
The purpose of this study was to evaluate the clinical and laboratory data of children with acute gastroenteritis caused by non-typhoid Salmonella spp. infections. Clinical (demographic data, symptoms and findings) and laboratory data (stool microscopy, rapid antigen tests, culture, multiplex polymerase chain reaction and blood test results) of children with acute gastroenteritis caused by non-typhoid Salmonella spp. between January 2010 and October 2012 were evaluated. Differences between the groups for categorical variables were estimated with a chi-square or Fisher exact test; for continuous variables with two independent samples a t test was used. P values < 0.05 were considered statistically significant. Sixty-seven children, 39 (58.2%) males and 28 (41.8%) females aged between 1 - 16 years (mean ± SD: 4.64 ± 2.91), were diagnosed with acute bacterial gastroenteritis caused by non-typhoid Salmonella spp. The main serotypes are Salmonella enteritidis (85%) and Salmonella typhimurium (7.5%). The presenting symptoms were diarrhoea (95.5%), fever (61.1%), vomiting (34.3%), abdominal pain (32.8%), loss of appetite (7.4%) and malaise (7.4%). Fever and dehydration (moderate and/or severe) were detected in 11 (16.4%) patients. The mean leukocyte count was 10.930/μL [95% confidence interval (CI), SD: ± 5.710/μL], neutrophil count was 7.880/μL (95% CI, SD: ± 4.960/μL), CRP was 64.16 mg/L (95% CI, SD: ± 76.24 mg/L), and erythrocyte sedimentation rate was 34.72 mm/hour (95% CI, SD: ± 13.64 mm/h). Stool microscopy was positive for leukocytes in 18 patients (26.8%). The definitive diagnosis was made with positive stool culture (n = 65) and/or PCR test (n = 4). Viral antigen positivity was detected in 10 patients (14.9%), evaluated as viral co-infection and false positive results. Antibiotic therapy and hospitalization were required in 26 (38.8%) and 23 (34.3%) patients, respectively. Salmonella carriage was detected in one patient (1.5%). Bloody diarrhoea, leukocytes in stool with an increased erythrocyte sedimentation rate and a CRP level without overt leukocytosis may indicate Salmonella infection. Viral antigens may cause false positive results in fast antigen tests in cases where clinical and laboratory findings indicate bacterial aetiology. Stool culture is a reference method in diagnosis whereas some agents may be detected via molecular techniques (polymerase chain reaction) in spite of negative culture. Multiplex polymerase chain reaction may be used to detect Salmonella spp. and may reveal false positivity for viruses as well as the detection of other bacteria.
Present Concepts in Internal Medicine. Volume 13, Number 1. Endocrinology Research Symposium,
1980-01-01
Liddle suppression test in which dexamethasone 0.5 mg q6h (2 mg/day) is given for two days with collection of urine 17-OHCS. 3 Confirmation of the...diagnosis is best established by measurement of urine free cortisol which has the advantage of not being elevated in obesity.4 False negatives occur in 10...experience (in the absence of conditions causing false positive responses) the presence of elevated urine free cortisol (> 100 Vg/24 h) and lack of
INFRARED- BASED BLINK DETECTING GLASSES FOR FACIAL PACING: TOWARDS A BIONIC BLINK
Frigerio, Alice; Hadlock, Tessa A; Murray, Elizabeth H; Heaton, James T
2015-01-01
IMPORTANCE Facial paralysis remains one of the most challenging conditions to effectively manage, often causing life-altering deficits in both function and appearance. Facial rehabilitation via pacing and robotic technology has great yet unmet potential. A critical first step towards reanimating symmetrical facial movement in cases of unilateral paralysis is the detection of healthy movement to use as a trigger for stimulated movement. OBJECTIVE To test a blink detection system that can be attached to standard eyeglasses and used as part of a closed-loop facial pacing system. DESIGN Standard safety glasses were equipped with an infrared (IR) emitter/detector pair oriented horizontally across the palpebral fissure, creating a monitored IR beam that became interrupted when the eyelids closed. SETTING Tertiary care Facial Nerve Center. PARTICIPANTS 24 healthy volunteers. MAIN OUTCOME MEASURE Video-quantified blinking was compared with both IR sensor signal magnitude and rate of change in healthy participants with their gaze in repose, while they shifted gaze from central to far peripheral positions, and during the production of particular facial expressions. RESULTS Blink detection based on signal magnitude achieved 100% sensitivity in forward gaze, but generated false-detections on downward gaze. Calculations of peak rate of signal change (first derivative) typically distinguished blinks from gaze-related lid movements. During forward gaze, 87% of detected blink events were true positives, 11% were false positives, and 2% false negatives. Of the 11% false positives, 6% were associated with partial eyelid closures. During gaze changes, false blink detection occurred 6.3% of the time during lateral eye movements, 10.4% during upward movements, 46.5% during downward movements, and 5.6% for movements from an upward or downward gaze back to the primary gaze. Facial expressions disrupted sensor output if they caused substantial squinting or shifted the glasses. CONCLUSION AND RELEVANCE Our blink detection system provides a reliable, non-invasive indication of eyelid closure using an invisible light beam passing in front of the eye. Future versions will aim to mitigate detection errors by using multiple IR emitter/detector pairs mounted on the glasses, and alternative frame designs may reduce shifting of the sensors relative to the eye during facial movements. PMID:24699708
Shin, Jae Il; Lee, Jae Seung; Jang, Young Ho; Kim, Sung Hun; Lee, Kang Hyuk; Lee, Chang Hoon
2009-01-01
A 16-month-old boy was admitted because of cough that had lasted for 10 days. The patient showed severe hepatomegaly incidentally, and dual positivity of Immunoglobulin (Ig) M to Epstein-Barr virus (EBV) viral capsid antigen (VCA) and cytomegalovirus (CMV). On the basis of seroconversion to Epstein-Barr nuclear antigen (EBNA) Ig G positivity and reduced CMV Ig M titer with persistently negative CMV Ig G, a definite diagnosis of EBV-induced infectious mononucleosis was established 1 year 2 month later. PMID:19881978
Park, Jee Min; Shin, Jae Il; Lee, Jae Seung; Jang, Young Ho; Kim, Sung Hun; Lee, Kang Hyuk; Lee, Chang Hoon
2009-10-31
A 16-month-old boy was admitted because of cough that had lasted for 10 days. The patient showed severe hepatomegaly incidentally, and dual positivity of Immunoglobulin (Ig) M to Epstein-Barr virus (EBV) viral capsid antigen (VCA) and cytomegalovirus (CMV). On the basis of seroconversion to Epstein-Barr nuclear antigen (EBNA) Ig G positivity and reduced CMV Ig M titer with persistently negative CMV Ig G, a definite diagnosis of EBV-induced infectious mononucleosis was established 1 year 2 month later.
A Positive Emotional Bias in Confabulatory False Beliefs about Place
ERIC Educational Resources Information Center
Turnbull, Oliver H.; Berry, Helen; Evans, Cathryn E.Y.
2004-01-01
Some neurological patients with medial frontal lesions exhibit striking confabulations. Most accounts of the cause of confabulations are cognitive, though the literature has produced anecdotal suggestions that confabulations may not be emotionally neutral, having a ("wish-fulfillment") bias that shapes the patient's perception of reality in a more…
Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi
2005-01-01
We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.
[False positive of DUPAN-2 caused by IgM-human anti mouse antibody].
Abe, Masaki; Hyoki, Miyuki; Abe, Ikurou; Kaito, Ken; Takagi, Ichirou
2012-11-01
We investigated a case in our experience presenting false-positive for DUPAN-2 by IgM-human anti mouse antibody (HAMA). A female aged 40s has been treated in our hospital from 2003. Her serum level of DUPAN-2 in 2005 and 2006 were 110 U/mL and 140 U/mL respectively. While this level was increased to 770 U/ml in 2007, and kept in the higher level so far. Around years of 2007, no meaning changes was detected by radiological and laboratory tests, and there was no significant change in her clinical signs and symptoms and medications. The elevation of DUPAN-2 was thought as a false-positive phenomenon and the mechanism was investigated. As results, no dilution lineality was found, and absorption test showed a 95% reduction of DUPAN-2 levels not by IgG and IgA, but IgM-specific antiserum. Dithiothreitoldeacylation test with neuraminidase, and absorption test with HBR-1, IIR, and mouse IgM serum, it was suggested that the IgM with HAMA activity of the patient reacted with mouse monoclonal antibodies in reagents. Moreover, the HPLC-eluted fraction of DUPAN-2 of this patients was detected in the fraction of IgM, which as different from that of a control pancreatic cancer patient. Above these data, elevation of DUPAN-2 in this patient was a false positive phenomenon by IgM-HAMA reacting with mouse monoclonal antibodies in reagents. Although there are few reported cases of false positive phenomenon in DUPAN-2 measurement, we have to pay attention to such phenomenon when detecting an unlikely higher levels that could not be explained by clinical information.
Mi, Tian; Merlin, Jerlin Camilus; Deverasetty, Sandeep; Gryk, Michael R; Bill, Travis J; Brooks, Andrew W; Lee, Logan Y; Rathnayake, Viraj; Ross, Christian A; Sargeant, David P; Strong, Christy L; Watts, Paula; Rajasekaran, Sanguthevar; Schiller, Martin R
2012-01-01
Minimotif Miner (MnM available at http://minimotifminer.org or http://mnm.engr.uconn.edu) is an online database for identifying new minimotifs in protein queries. Minimotifs are short contiguous peptide sequences that have a known function in at least one protein. Here we report the third release of the MnM database which has now grown 60-fold to approximately 300,000 minimotifs. Since short minimotifs are by their nature not very complex we also summarize a new set of false-positive filters and linear regression scoring that vastly enhance minimotif prediction accuracy on a test data set. This online database can be used to predict new functions in proteins and causes of disease.
One-day fluorescent-antibody procedure for detecting salmonellae in frozen and dried foods.
Goepfert, J M; Mann, M E; Hicks, R
1970-12-01
The indirect fluorescent-antibody technique was used to examine 422 food samples for the presence of salmonellae. A cultural phase involving a 16-hr preenrichment in buffered nutrient broth-milk medium followed by a 4- to 5-hr subculture into fresh medium of the same composition was evaluated. This procedure yielded a sufficient population of salmonellae so that no false-negative results were obtained. Of the 31 false-positives obtained, 12 samples yielded positive cultural results upon extensive subculture of the original enrichment broths. Yeast cells and both vegetative and spore forms of bacilli were observed to fluoresce when stained with anti-Salmonella serum. Efforts to ascertain the cause of these cross-reactions and several alternate explanations are discussed.
Galkin, O Yu; Besarab, A B; Lutsenko, T N
2017-01-01
The goal of this work was to study sensitivity and specificity of the developed ELISA set for the identification of IgG antibodies against Chlamydia trachomatis HSP-60 (using biotinylated tyramine-based signal amplification system). The study was conducted using a panel of characterized sera, as well as two reference ELISA sets of similar purpose. According to the results of ELISA informative value parameters, the ELISA we have developed showed the highest specificity and sensitivity parameters (no false negative or false positive results were registered). In 4 out of 15 intralaboratory panel serum samples initially identified as negative, anti-HSP-60 IgG-antibodies test result in reference ELISA sets upon dilution changed from negative to positive. The nature of titration curves of false negative sera and commercial monoclonal antibodies А57-В9 against C. trachomatis HSP-60 after incubation for 24 h was indicative of the presence of anti-idiotypic antibodies in these samples. Upon sera dilution, idiotypic-anti-idiotypic complexes dissociated, which caused the change of test result. High informative value of the developed ELISA set for identification of IgG antibodies against C. trachomatis HSP-60 has been proven. Anti-idiotypic antibodies possessing C. trachomatis anti-HSP-60 activity and being one of the causes of false negative results of the relevant ELISA-based tests have been identified in blood sera of individuals infected with chlamydial genitourinary infection agents.
Detection of Fundus Lesions Using Classifier Selection
NASA Astrophysics Data System (ADS)
Nagayoshi, Hiroto; Hiramatsu, Yoshitaka; Sako, Hiroshi; Himaga, Mitsutoshi; Kato, Satoshi
A system for detecting fundus lesions caused by diabetic retinopathy from fundus images is being developed. The system can screen the images in advance in order to reduce the inspection workload on doctors. One of the difficulties that must be addressed in completing this system is how to remove false positives (which tend to arise near blood vessels) without decreasing the detection rate of lesions in other areas. To overcome this difficulty, we developed classifier selection according to the position of a candidate lesion, and we introduced new features that can distinguish true lesions from false positives. A system incorporating classifier selection and these new features was tested in experiments using 55 fundus images with some lesions and 223 images without lesions. The results of the experiments confirm the effectiveness of the proposed system, namely, degrees of sensitivity and specificity of 98% and 81%, respectively.
Burns, Joseph E.; Yao, Jianhua; Muñoz, Hector
2016-01-01
Purpose To design and validate a fully automated computer system for the detection and anatomic localization of traumatic thoracic and lumbar vertebral body fractures at computed tomography (CT). Materials and Methods This retrospective study was HIPAA compliant. Institutional review board approval was obtained, and informed consent was waived. CT examinations in 104 patients (mean age, 34.4 years; range, 14–88 years; 32 women, 72 men), consisting of 94 examinations with positive findings for fractures (59 with vertebral body fractures) and 10 control examinations (without vertebral fractures), were performed. There were 141 thoracic and lumbar vertebral body fractures in the case set. The locations of fractures were marked and classified by a radiologist according to Denis column involvement. The CT data set was divided into training and testing subsets (37 and 67 subsets, respectively) for analysis by means of prototype software for fully automated spinal segmentation and fracture detection. Free-response receiver operating characteristic analysis was performed. Results Training set sensitivity for detection and localization of fractures within each vertebra was 0.82 (28 of 34 findings; 95% confidence interval [CI]: 0.68, 0.90), with a false-positive rate of 2.5 findings per patient. The sensitivity for fracture localization to the correct vertebra was 0.88 (23 of 26 findings; 95% CI: 0.72, 0.96), with a false-positive rate of 1.3. Testing set sensitivity for the detection and localization of fractures within each vertebra was 0.81 (87 of 107 findings; 95% CI: 0.75, 0.87), with a false-positive rate of 2.7. The sensitivity for fracture localization to the correct vertebra was 0.92 (55 of 60 findings; 95% CI: 0.79, 0.94), with a false-positive rate of 1.6. The most common cause of false-positive findings was nutrient foramina (106 of 272 findings [39%]). Conclusion The fully automated computer system detects and anatomically localizes vertebral body fractures in the thoracic and lumbar spine on CT images with a high sensitivity and a low false-positive rate. © RSNA, 2015 Online supplemental material is available for this article. PMID:26172532
Computerized tomography tailored for the assessment of microscopic hematuria.
Lang, Erich K; Macchia, Richard J; Thomas, Raju; Ruiz-Deya, Gilberto; Watson, Richard A; Richter, Frank; Irwin R, Robert; Marberger, Michael; Mydlo, Jack; Lechner, Gerhard; Cho, Kyunghee C; Gayle, Brian
2002-02-01
We report the results of a multicenter study of arterial, corticomedullary, nephrographic and excretory phase helical computerized tomography (CT) for detecting and characterizing abnormalities causing asymptomatic microscopic hematuria. We evaluated 350 consecutive patients, including 216 men and 134 women 23 to 88 years old, with asymptomatic microscopic hematuria of undetermined cause at 4 medical centers. Patients with known urological pathology were excluded from study. We performed 4 helical CT sequences, including pre-enhancement phase imaging from kidney to symphysis pubis, arterial phase imaging of the kidney and lower pelvis, corticomedullary nephrographic phase imaging of the kidney and lower pelvis, and excretory phase imaging from kidney to symphysis pubis with 2 to 5 mm. collimation and 1 to 1.5 pitch. Of 171 proved lesions 158 were correctly diagnosed. There were 10 false-positive and 13 false-negative diagnoses, indicating 0.9239 sensitivity, 0.9441 specificity, 0.9404 positive and 0.9285 negative predictive values, (p <0.001). All cases of congenital renal lesions, calculous disease, ureteral lesion and neoplastic lesion of the bladder were correctly diagnosed, as were 40 of 41 inflammatory renal, 21 of 23 renal masses and 13 of 16 inflammatory bladder lesions. In 27 patients with renal calculi the study was limited to pre-enhancement spiral CT. A positive diagnosis rate of 45.1% (158 of 350 cases) for the causes of heretofore refractory cases of hematuria with high sensitivity and specificity attest to the effectiveness of our hematuria CT protocol and support its use.
Systematic Errors in Peptide and Protein Identification and Quantification by Modified Peptides*
Bogdanow, Boris; Zauber, Henrik; Selbach, Matthias
2016-01-01
The principle of shotgun proteomics is to use peptide mass spectra in order to identify corresponding sequences in a protein database. The quality of peptide and protein identification and quantification critically depends on the sensitivity and specificity of this assignment process. Many peptides in proteomic samples carry biochemical modifications, and a large fraction of unassigned spectra arise from modified peptides. Spectra derived from modified peptides can erroneously be assigned to wrong amino acid sequences. However, the impact of this problem on proteomic data has not yet been investigated systematically. Here we use combinations of different database searches to show that modified peptides can be responsible for 20–50% of false positive identifications in deep proteomic data sets. These false positive hits are particularly problematic as they have significantly higher scores and higher intensities than other false positive matches. Furthermore, these wrong peptide assignments lead to hundreds of false protein identifications and systematic biases in protein quantification. We devise a “cleaned search” strategy to address this problem and show that this considerably improves the sensitivity and specificity of proteomic data. In summary, we show that modified peptides cause systematic errors in peptide and protein identification and quantification and should therefore be considered to further improve the quality of proteomic data annotation. PMID:27215553
A case of placental trisomy 18 mosaicism causing a false negative NIPT result.
Yang, Jiexia; Qi, Yiming; Guo, Fangfang; Hou, Yaping; Peng, Haishan; Wang, Dongmei; Oy, Haoxin; Yin, Aihua
2017-01-01
The non-invasive prenatal testing that evaluates circulating cell free DNA, and has been established as an additional pregnancy test for detecting the common fetal trisomies 21, 18 and 13 is rapidly revolutionizing prenatal screening as a result of its increased sensitivity and specificity. However, false positive and false negative results still exist. We presented a case in which the non-invasive prenatal testing results were normal at 15 gestational age (GA), but an ultrasound examination at 30GA showed that the fetus had heart abnormalities, and the third trimester ultrasound at 33GA noted multiple anomalies including a 3.0 mm ventricular septal defect. Along with cordocentesis at 33GA, the cord blood sample cytogenetics analysis showed a mos 47,XN,+18[61]/46,XN[39] T18 karyotype. Six placental biopsies confirmed that the chromosome 18 placenta chimerism ratio had changed from 33% to 72%. Ultimately, the pregnancy was interrupted at 34GA. We presented this case to highlight the need to clearly explain false positive or false negative results to patients. We believe that this information will also influence the development of future diagnostic test methodologies.
Automated microaneurysm detection method based on double ring filter in retinal fundus images
NASA Astrophysics Data System (ADS)
Mizutani, Atsushi; Muramatsu, Chisako; Hatanaka, Yuji; Suemori, Shinsuke; Hara, Takeshi; Fujita, Hiroshi
2009-02-01
The presence of microaneurysms in the eye is one of the early signs of diabetic retinopathy, which is one of the leading causes of vision loss. We have been investigating a computerized method for the detection of microaneurysms on retinal fundus images, which were obtained from the Retinopathy Online Challenge (ROC) database. The ROC provides 50 training cases, in which "gold standard" locations of microaneurysms are provided, and 50 test cases without the gold standard locations. In this study, the computerized scheme was developed by using the training cases. Although the results for the test cases are also included, this paper mainly discusses the results for the training cases because the "gold standard" for the test cases is not known. After image preprocessing, candidate regions for microaneurysms were detected using a double-ring filter. Any potential false positives located in the regions corresponding to blood vessels were removed by automatic extraction of blood vessels from the images. Twelve image features were determined, and the candidate lesions were classified into microaneurysms or false positives using the rule-based method and an artificial neural network. The true positive fraction of the proposed method was 0.45 at 27 false positives per image. Forty-two percent of microaneurysms in the 50 training cases were considered invisible by the consensus of two co-investigators. When the method was evaluated for visible microaneurysms, the sensitivity for detecting microaneurysms was 65% at 27 false positives per image. Our computerized detection scheme could be improved for helping ophthalmologists in the early diagnosis of diabetic retinopathy.
Rácil, Z; Kocmanová, I; Wagnerová, B; Winterová, J; Lengerová, M; Moulis, M; Mayer, J
2008-01-01
PREMISES AND OBJECTIVES: Timely diagnosis is of critical importance for the prognosis of invasive aspergilosis (IA) patients. Over recent years, IA detection of galactomannan using the ELISA method has assumed growing importance. The objective of the study was to analyse the usability of the method in current clinical practice of a hemato-oncological ward. From May 2003 to October 2006, blood samples were taken from patients at IA risk to detect galactomannan (GM) in serum using the ELISA method. The patients who underwent the tests were classified by the probability of IA presence on the basis of the results of conventional diagnostic methods and section findings. A total of 11,360 serum samples from 911 adult patients were tested for GM presence. IA (probable/proven) was diagnosed in 42 (4.6%) of them. The rates of sensitivity, specificity, positive and negative predictive value of galactomannan detection for IA diagnosis in our ward were, respectively, 95.2%, 90.0%, 31.5% and 99.7%. The principal causes of the limited positive predictive value of the test were the high percentage of false-positive test results (mainly caused by concomitant administration of some penicillin antibiotics or Plasma-Lyte infusion solution), as well as the fact that a large percentage of patients we examined fell within the group of patients with hematological malignity with a very low prevalence of IA. GM detection in serum is associated with high sensitivity and excellent negative predictive value in IA diagnosis in hemato-oncological patients. Knowledge and elimination of possible causes of false-positive results as well as focusing the screening on patients at greatest risk of infection are necessary for an even better exploitation of the test.
Tyagi, Ruchita; Gupta, Nalini; Bhagat, Priyanka; Gainder, Shalini; Rai, Bhavna; Dhaliwal, L K; Rajwanshi, Arvind
2017-01-01
Context: Peritoneal washing is performed for staging of gynecologic tumors to detect subclinical intraperitoneal metastases. Aim: The aim of the present study was to assess the impact of SurePath™ liquid-based cytology (LBC) in peritoneal washing in various gynecological malignancies. Settings and Design: An audit of peritoneal-fluid/washing (January 2012 to July 2013) was performed with corresponding gynecologic specimens. All peritoneal washings were processed using both conventional and LBC technique. Suspicious cases on cytology were reported along with gynecologic specimens. Results: There were a total of 393 peritoneal fluids. Eighty-three (21.1%) were positive for malignancy, and the corresponding histology was available in 352 (89.6%) cases. Sixty-nine positive samples had ovarian malignancies and 5 had uterine causes. There were 9 cases of peritoneal washings in which no histopathology was available. The most common cause of positive peritoneal cytology was ovarian serous carcinoma in 55/84 (65.5%) cases. Other causes included mucinous cystadenocarcinoma, dysgerminoma, squamous cell carcinoma in teratoma, yolk sac tumor, and granulosa cell tumor. Uterine causes included 2/45 (4.4%) cases of endometrioid adenocarcinoma, ¼ (25%) cases of clear cell carcinoma, ½ (50%) cases of carcinosarcoma, and ¼ (25%) cervix carcinoma. On review of positive cases (n = 83), 10 cases were identified, which had nil (n = 4) to low cellularity (<3 tumor clusters/smear; n = 6) on conventional smears, and were confirmed malignant on LBC. Conclusions: The most common ovarian malignancy causing positive peritoneal cytology is papillary serous carcinoma. Endometrioid adenocarcinoma rarely leads to positive peritoneal cytology. LBC technique leads to concentration of tumor cells causing reduction in false negative cases, especially in hemorrhagic and low-cellular cases. PMID:28469317
van der Meulen, Miriam P; Lansdorp-Vogelaar, Iris; van Heijningen, Else-Mariëtte B; Kuipers, Ernst J; van Ballegooijen, Marjolein
2016-06-01
If some adenomas do not bleed over several years, they will cause systematic false-negative fecal immunochemical test (FIT) results. The long-term effectiveness of FIT screening has been estimated without accounting for such systematic false-negativity. There are now data with which to evaluate this issue. The authors developed one microsimulation model (MISCAN [MIcrosimulation SCreening ANalysis]-Colon) without systematic false-negative FIT results and one model that allowed a percentage of adenomas to be systematically missed in successive FIT screening rounds. Both variants were adjusted to reproduce the first-round findings of the Dutch CORERO FIT screening trial. The authors then compared simulated detection rates in the second screening round with those observed, and adjusted the simulated percentage of systematically missed adenomas to those data. Finally, the authors calculated the impact of systematic false-negative FIT results on the effectiveness of repeated FIT screening. The model without systematic false-negativity simulated higher detection rates in the second screening round than observed. These observed rates could be reproduced when assuming that FIT systematically missed 26% of advanced and 73% of nonadvanced adenomas. To reduce the false-positive rate in the second round to the observed level, the authors also had to assume that 30% of false-positive findings were systematically false-positive. Systematic false-negative FIT testing limits the long-term reduction of biennial FIT screening in the incidence of colorectal cancer (35.6% vs 40.9%) and its mortality (55.2% vs 59.0%) in participants. The results of the current study provide convincing evidence based on the combination of real-life and modeling data that a percentage of adenomas are systematically missed by repeat FIT screening. This impairs the efficacy of FIT screening. Cancer 2016;122:1680-8. © 2016 American Cancer Society. © 2016 American Cancer Society.
Aller-Morán, Luis M; Martínez-Lobo, F Javier; Rubio, Pedro; Carvajal, Ana
2016-11-01
An emerging novel spirochete in swine, provisionally designated "Brachyspira hampsonii," has been detected worldwide. It has been associated with swine dysentery and cannot be differentiated from B. hyodysenteriae, the classical etiologic agent of this disease, using standard phenotypic methods. We evaluated cross-reactions of "B. hampsonii" isolates recovered from avian species in some of the currently available species-specific polymerase chain reaction (PCR) assays for the identification of swine Brachyspira species. Ten avian "B. hampsonii" isolates recovered from wild waterfowl were used. No false-positive results were recorded with a B. pilosicoli-specific PCR based on the amplification of a fragment of the 16S rRNA gene. However, the percentage of false-positive results varied, with a range of 10-80%, in the evaluated B. hyodysenteriae-specific assays based on the amplification of the 23S rRNA, nox, and tlyA genes. Similarly, results of the B. intermedia-specific PCR assays yielded poor specificity, with up to 80% of the "B. hampsonii" isolates tested giving false-positive results. Finally, 2 "B. hampsonii" avian isolates yielded a positive result in a B. innocens- and B. murdochii-specific PCR. This result should be interpreted very cautiously as these 2 isolates could represent a recombinant genotype. © 2016 The Author(s).
Rogot, E; Feinleib, M; Ockay, K A; Schwartz, S H; Bilgrad, R; Patterson, J E
1983-01-01
To test the feasibility of using large national probability samples provided by the US Census Bureau, a pilot project was initiated to link 230,000 Census-type records to the National Death Index (NDI). Using strict precautions to maintain the complete confidentiality of individual records, the Current Population Survey files of one month in 1973 and one month in 1978 were matched by computer to the 1979 NDI file. The basic question to be addressed was whether deaths so obtained are seriously underestimated when there is no Social Security Number (SSN) in the Census record. The search of the NDI file resulted in 5,542 matches of which about 1,800 appear to be "true positives" representing deaths, the remainder are "false positives." Of the deaths, 80 per cent would still have been detected without SSN in the Census record. The main reasons for missing deaths (false negatives) were discrepancies in the year of birth and in the given name. Assuming certain changes in the NDI matching algorithm, the 80 per cent figure could increase to 85 per cent or higher; however, this could also cause significant increases in the number of false positives. The National Heart, Lung and Blood Institute (NHLBI) and Census Bureau staff are currently developing a probabilistic method to eliminate false positives from the NDI output tape. The results of the pilot study indicate that a larger research project is clearly feasible. PMID:6625029
Mostafa, Mohamed; Vali, Reza; Chan, Jeffrey; Omarkhail, Yusuaf; Shammas, Amer
2016-10-01
Potentially false-positive findings on radioiodine scans in children with differentiated thyroid carcinoma can mimic functioning thyroid tissue and functioning thyroid carcinomatous tissue. Such false-positive findings comprise variants and pitfalls that can vary slightly in children as compared with adults. To determine the patterns and frequency of these potential false-positive findings on radioiodine scans in children with differentiated thyroid carcinoma. We reviewed a total of 223 radioiodine scans from 53 pediatric patients (mean age 13.3 years, 37 girls) with differentiated thyroid carcinoma. Focal or regional activity that likely did not represent functioning thyroid tissue or functioning thyroid carcinomatous tissue were categorized as variants or pitfalls. The final diagnosis was confirmed by reviewing the concurrent and follow-up clinical data, correlative ultrasonography, CT scanning, serum thyroglobulin and antithyroglobulin antibody levels. We calculated the frequency of these variants and pitfalls from diagnostic and post-therapy radioiodine scans. The most common variant on the radioiodine scans was the thymic activity (24/223, 10.8%) followed by the cardiac activity (8/223, 3.6%). Salivary contamination and star artifact, caused by prominent thyroid remnant, were the most important observed pitfalls. Variants and pitfalls that mimic functioning thyroid tissue or functioning thyroid carcinomatous tissue on radioiodine scan in children with differentiated thyroid carcinoma are not infrequent, but they decrease in frequency on successive radioiodine scans. Potential false-positive findings can be minimized with proper knowledge of the common variants and pitfalls in children and correlation with clinical, laboratory and imaging data.
Hiura, Masahito; Nakajima, Osamu; Mori, Toshizumi; Kitano, Katsuya
2005-10-01
We evaluated the accuracy of visually reading the whole blood Rapicheck H-FABP panel test using the quantitative plasma H-FABP concentration as the reference. Consecutive patients with chest pain (n = 237) who were suspected of having acute myocardial infarction were recruited. The appearance of an evident test line within 5 min was given a grade of +3 (strongly positive), appearance within 15 min +2 (moderately positive) and the appearance of a weak test line within 15 min +1 (weakly positive). The concordance rates were 91.8% for positive, 70.1% for negative and 80.2% for overall. Plasma H-FABP concentrations were above the cut-off value for 9.2% of negative (0) results. Fifty percent of weakly positive (+1) and 25.0% of moderately positive (+2) results had H-FABP concentrations lower than the cut-off value. All of the strongly positive (+3) were above the cut-off value. These results suggested that the false-positive and false-negative results of Rapicheck H-FABP were caused by over or underestimation in visual reading when the plasma H-FABP concentration was near the cut-off concentration. Low accuracy of visual reading of Rapicheck H-FABP was due to poor estimation by manual reading around the cut-off value.
Extensive testing or focused testing of patients with elevated liver enzymes.
Tapper, Elliot B; Saini, Sameer D; Sengupta, Neil
2017-02-01
Many patients have elevated serum aminotransferases reflecting many underlying conditions, both common and rare. Clinicians generally apply one of two evaluative strategies: testing for all diseases at once (extensive) or just common diseases first (focused). We simulated the evaluation of 10,000 adult outpatients with elevated with alanine aminotransferase to compare both testing strategies. Model inputs employed population-based data from the US (National Health and Nutrition Examination Survey) and Britain (Birmingham and Lambeth Liver Evaluation Testing Strategies). Patients were followed until a diagnosis was provided or a diagnostic liver biopsy was considered. The primary outcome was US dollars per diagnosis. Secondary outcomes included doctor visits per diagnosis, false-positives per diagnosis and confirmatory liver biopsies ordered. The extensive testing strategy required the lowest monetary cost, yielding diagnoses for 54% of patients at $448/patient compared to 53% for $502 under the focused strategy. The extensive strategy also required fewer doctor visits (1.35 vs. 1.61 visits/patient). However, the focused strategy generated fewer false-positives (0.1 vs. 0.19/patient) and more biopsies (0.04 vs. 0.08/patient). Focused testing becomes the most cost-effective strategy when accounting for pre-test probabilities and prior evaluations performed. This includes when the respective prevalence of alcoholic, non-alcoholic and drug-induced liver disease exceeds 51.1%, 53.0% and 13.0%. Focused testing is also the most cost-effective strategy in the referral setting where assessments for viral hepatitis, alcoholic and non-alcoholic fatty liver disease have already been performed. Testing for elevated liver enzymes should be deliberate and focused to account for pre-test probabilities if possible. Many patients have elevated liver enzymes reflecting one of many possible liver diseases, some of which are very common and some of which are rare. Tests are widely available for most causes but it is unclear whether clinicians should order them all at once or direct testing based on how likely a given disease may be given the patient's history and physical exam. The tradeoffs of both approaches involve the money spent on testing, number of office visits needed, and false positive results generated. This study shows that if there are no clues available at the time of evaluation, testing all at once saves time and money while causing more false positives. However, if there are strong clues regarding the likelihood of a particular disease, limited testing saves time, money and prevents false positives. Copyright © 2016 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.
False Position, Double False Position and Cramer's Rule
ERIC Educational Resources Information Center
Boman, Eugene
2009-01-01
We state and prove the methods of False Position (Regula Falsa) and Double False Position (Regula Duorum Falsorum). The history of both is traced from ancient Egypt and China through the work of Fibonacci, ending with a connection between Double False Position and Cramer's Rule.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berquist, T.H.; Nolan, N.G.; Stephens, D.H.
1976-06-01
Numerous reports in the recent literature have questioned the value of abdominal scanning with pertechnetate in the diagnosis of Meckel's diverticulum. In an attempt to evaluate further the specificity of pertechnetate in this condition, the clinical data and scintigrams of 100 patients with suspected Meckel's diverticulum were reviewed. The scintigram correctly identified Meckel's diverticulum before operation in seven of eight patients. One false-negative study occurred in 33 patients who underwent laparotomy. Conditions suggested as possible causes of false-positive studies (hydronephrosis, arteriovenous malformations, and intussusception) were found to give negative scans. (auth)
18F-FDG PET/CT in detection of gynecomastia in patients with hepatocellular carcinoma.
Wang, Hsin-Yi; Jeng, Long-Bin; Lin, Ming-Chia; Chao, Chih-Hao; Lin, Wan-Yu; Kao, Chia-Hung
2013-01-01
We retrospectively investigate the prevalence of gynecomastia as false-positive 2-[18F]fluoro-2-deoxy-d-glucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) imaging in patients with hepatocellular carcinoma (HCC). Among the 127 male HCC patients who underwent 18F-FDG PET/CT scan, the 18FDG uptakes at the bilateral breasts in 9 patients with gynecomastia were recorded as standard uptake value (SUVmax) and the visual interpretation in both early and delayed images. The mean early SUVmax was 1.58/1.57 (right/left breast) in nine gynecomastia patients. The three patients with early visual score of 3 had higher early SUVmaxs. Gynecomastia is a possible cause of false-positive uptake on 18F-FDG PET/CT images. Copyright © 2013 Elsevier Inc. All rights reserved.
Bachrach, D G; Bendoly, E; Podsakoff, P M
2001-12-01
The purpose of this study was to examine the possibility that feedback regarding team performance may influence team members' reports of organizational citizenship behaviors. Ninety-five teams of business students (N = 412) participated in a labor-scheduling simulation over a local area network. Teams were provided with false negative, false positive, or neutral feedback regarding their performance. Results support the hypothesis that the perception of 2 forms of organizational citizenship behavior (helping behavior and civic virtue) in work groups may, in part. be a function of the nature of the performance feedback that group members receive. However, negative feedback appears to play a more critical role than positive feedback in this attributional process. Possible reasons for these findings, as well as their implications, are discussed.
Tse, Herman; Chan, Elaine; Lam, Ching-Wan; Leung, Ka-Fai; Chow, Pat; Lee, Kim-Chung; Sze, Kong-Hung; Cheung, Stanley K. K.; Tse, Man-Kit; Ho, Pak-Leung; Leung, Sze-Pui; Lau, Susanna K. P.; Woo, Patrick C. Y.
2012-01-01
Staphylococcus aureus can be distinguished from similar coagulase-positive staphylococci by its absence of β-galactosidase activity. This is commonly tested using o-nitrophenyl-β-d-galactopyranoside (ONPG) as the substrate. Unexpectedly, 111 and 58 of 123 isolates displayed apparent β-galactosidase activity in the ONPG assay and on the Vitek 2 system, respectively. Compositional analysis showed that the yellow coloration of the positive ONPG assay resulted from production of 2-aminophenoxazin-3-one. Alternative β-galactosidase substrates like X-Gal (5-bromo-4-chloro-3-indolyl-β-d-galactopyranoside) should be used for testing staphylococci. PMID:22972831
Is MMTV associated with human breast cancer? Maybe, but probably not.
Perzova, Raisa; Abbott, Lynn; Benz, Patricia; Landas, Steve; Khan, Seema; Glaser, Jordan; Cunningham, Coleen K; Poiesz, Bernard
2017-10-13
Conflicting results regarding the association of MMTV with human breast cancer have been reported. Published sequence data have indicated unique MMTV strains in some human samples. However, concerns regarding contamination as a cause of false positive results have persisted. We performed PCR assays for MMTV on human breast cancer cell lines and fresh frozen and formalin fixed normal and malignant human breast epithelial samples. Assays were also performed on peripheral blood mononuclear cells from volunteer blood donors and subjects at risk for human retroviral infections. In addition, assays were performed on DNA samples from wild and laboratory mice. Sequencing of MMTV positive samples from both humans and mice were performed and phylogenetically compared. Using PCR under rigorous conditions to prevent and detect "carryover" contamination, we did detect MMTV DNA in human samples, including breast cancer. However, the results were not consistent and seemed to be an artifact. Further, experiments indicated that the probable source of false positives was murine DNA, containing endogenous MMTV, present in our building. However, comparison of published and, herein, newly described MMTV sequences with published data, indicates that there are some very unique human MMTV sequences in the literature. While we could not confirm the true presence of MMTV in our human breast cancer subjects, the data indicate that further, perhaps more traditional, retroviral studies are warranted to ascertain whether MMTV might rarely be the cause of human breast cancer.
Robust Detection of Rare Species Using Environmental DNA: The Importance of Primer Specificity
Wilcox, Taylor M.; McKelvey, Kevin S.; Young, Michael K.; Jane, Stephen F.; Lowe, Winsor H.; Whiteley, Andrew R.; Schwartz, Michael K.
2013-01-01
Environmental DNA (eDNA) is being rapidly adopted as a tool to detect rare animals. Quantitative PCR (qPCR) using probe-based chemistries may represent a particularly powerful tool because of the method’s sensitivity, specificity, and potential to quantify target DNA. However, there has been little work understanding the performance of these assays in the presence of closely related, sympatric taxa. If related species cause any cross-amplification or interference, false positives and negatives may be generated. These errors can be disastrous if false positives lead to overestimate the abundance of an endangered species or if false negatives prevent detection of an invasive species. In this study we test factors that influence the specificity and sensitivity of TaqMan MGB assays using co-occurring, closely related brook trout (Salvelinus fontinalis) and bull trout (S. confluentus) as a case study. We found qPCR to be substantially more sensitive than traditional PCR, with a high probability of detection at concentrations as low as 0.5 target copies/µl. We also found that number and placement of base pair mismatches between the Taqman MGB assay and non-target templates was important to target specificity, and that specificity was most influenced by base pair mismatches in the primers, rather than in the probe. We found that insufficient specificity can result in both false positive and false negative results, particularly in the presence of abundant related species. Our results highlight the utility of qPCR as a highly sensitive eDNA tool, and underscore the importance of careful assay design. PMID:23555689
Robust detection of rare species using environmental DNA: the importance of primer specificity.
Wilcox, Taylor M; McKelvey, Kevin S; Young, Michael K; Jane, Stephen F; Lowe, Winsor H; Whiteley, Andrew R; Schwartz, Michael K
2013-01-01
Environmental DNA (eDNA) is being rapidly adopted as a tool to detect rare animals. Quantitative PCR (qPCR) using probe-based chemistries may represent a particularly powerful tool because of the method's sensitivity, specificity, and potential to quantify target DNA. However, there has been little work understanding the performance of these assays in the presence of closely related, sympatric taxa. If related species cause any cross-amplification or interference, false positives and negatives may be generated. These errors can be disastrous if false positives lead to overestimate the abundance of an endangered species or if false negatives prevent detection of an invasive species. In this study we test factors that influence the specificity and sensitivity of TaqMan MGB assays using co-occurring, closely related brook trout (Salvelinus fontinalis) and bull trout (S. confluentus) as a case study. We found qPCR to be substantially more sensitive than traditional PCR, with a high probability of detection at concentrations as low as 0.5 target copies/µl. We also found that number and placement of base pair mismatches between the Taqman MGB assay and non-target templates was important to target specificity, and that specificity was most influenced by base pair mismatches in the primers, rather than in the probe. We found that insufficient specificity can result in both false positive and false negative results, particularly in the presence of abundant related species. Our results highlight the utility of qPCR as a highly sensitive eDNA tool, and underscore the importance of careful assay design.
From the RSNA refresher courses: US of the rotator cuff: pitfalls, limitations, and artifacts.
Rutten, Matthieu J C M; Jager, Gerrit J; Blickman, Johan G
2006-01-01
High-resolution ultrasonography (US) has gained increasing popularity as a diagnostic tool for assessment of the soft tissues in shoulder impingement syndrome. US is a powerful and accurate method for diagnosis of rotator cuff tears and other rotator cuff abnormalities, provided the examiner has a detailed knowledge of shoulder anatomy, uses a standardized examination technique, and has a thorough understanding of the potential pitfalls, limitations, and artifacts. False-positive sonographic findings of rotator cuff tears can be caused by the technique (anisotropy, transducer positioning, acoustic shadowing by the deltoid septum), by the anatomy (rotator cuff interval, supraspinatus-infraspinatus interface, musculotendinous junction, fibrocartilaginous insertion), or by disease (criteria for diagnosis of rotator cuff tears, tendon inhomogeneity, acoustic shadowing by scar tissue or calcification, rotator cuff thinning). False-negative sonographic findings of rotator cuff tears can be caused by the technique (transducer frequency, suboptimal focusing, imaging protocol, transducer handling), by the anatomy (nondiastasis of the ruptured tendon fibers, posttraumatic obscuration of landmarks), by disease (tendinosis, calcifications, synovial proliferation, granulation or scar tissue, bursal thickening, massive rotator cuff tears), or by patient factors (obesity, muscularity, limited shoulder motion). (c) RSNA, 2006.
Terry, Nicolas P
2000-01-01
There are three areas of potential legal exposure for an organization such as a trustmark authority involved in ehealth quality rating. First, an ehealth provider may make a complaint about negative or impliedly negative ratings rendered by the ratings body (false negative). Typically, a negative ratings complaint would rely on defamation or product disparagement causes of action. In some cases such complaints could be defended on the basis of absence of malice (US). Second, the rating body might render a positive rating on ehealth data that a third party allegedly relied upon and suffered injury (false positive). While the primary cause of action would be against the ehealth data provider, questions may arise as to possible liability of the trustmark authority. For example, some US liability exposure is possible based on cases involving the potential liability of product warrantors, trade associations and certifiers or endorsers. Third, a ratings body may face public law liability for its own web misfeasance. Several risk management approaches are possible and would not necessarily be mutually exclusive. These approaches will require careful investigation to assess their risk reduction potential and, in some cases, legislation.
2000-01-01
There are three areas of potential legal exposure for an organization such as a trustmark authority involved in e-health quality rating. First, an e-health provider may make a complaint about negative or impliedly negative ratings rendered by the ratings body (false negative). Typically, a negative ratings complaint would rely on defamation or product disparagement causes of action. In some cases such complaints could be defended on the basis of absence of malice (US). Second, the rating body might render a positive rating on e-health data that a third party allegedly relied upon and suffered injury (false positive). While the primary cause of action would be against the e-health data provider, questions may arise as to the possible liability of the trustmark authority. For example, some US liability exposure is possible based on cases involving the potential liability of product warrantors, trade associations, and certifiers or endorsers. Third, a ratings body may face public law liability for its own web misfeasance. Several risk management approaches are possible and would not necessarily be mutually exclusive. These approaches will require careful investigation to assess their risk reduction potential and, in some cases, the introduction of legislation. PMID:11720941
Alpha Elements' Effects on Planet Formation and the Hunt for Extragalactic Planets
NASA Astrophysics Data System (ADS)
Penny, Matthew; Rodriguez, Joseph E.; Beatty, Thomas; Zhou, George
2018-01-01
A star's likelihood of hosting a giant planet is well known to be strongly dependent on metallicity. However, little is known about what elements cause this correlation (e.g. bulk metals, iron, or alpha elements such as silicon and oxygen). This is likely because most planet searches target stars in the Galactic disk, and due to Galactic chemical evolution, alpha element abundances are themselves correlated with metallicity within a population. We investigate the feasibility of simultaneous transiting planet search towards the alpha-poor Sagittarius dwarf galaxy and alpha-rich Galactic bulge in a single field of view of DECam, that would enable a comparative study of planet frequency over an [alpha/Fe] baseline of ~0.4 dex. We show that a modestly sized survey could detect planet candidates in both populations, but that false positive rejection in Sgr Dwarf may be prohibitively expensive. Conversely, two-filter survey observations alone would be sufficient to rule out a large fraction of bulge false positives, enabling statistical validation of candidates with a modest follow-up investment. Although over a shorter [alpha/Fe] baseline, this survey would provide a test of whether it is alpha or iron that causes the planet metallicity correlation.
Sweat chloride concentrations in children with Idiopathic Nephrotic Syndrome.
Guglani, Lokesh; Moir, Devin; Jain, Amrish
2016-01-01
Idiopathic Nephrotic Syndrome (INS) has been believed to cause a false positive elevation of sweat chloride concentrations, as measured by the sweat test. Sweat tests were done for 11 children with acute onset INS at admission and again while they were in remission, with results being compared to normal historical controls. The initial sweat chloride concentration for 10 patients was normal (mean16.7 ± 11.02 mmol/L) and 1 patient had inadequate collection. This latter patient and two others were excluded during follow-up because of diagnoses other than INS. Sweat test results for the eight INS patients during follow up remained unchanged when they were in remission (16.94 ± 7.88 mmol/L; P = 0.98; Wilcoxon Matched-Pairs Signed Rank Test). In comparing sweat chloride concentrations from INS patients to those from 20 historical control subjects, we found no significant differences (Mann-Whitney Test; initial vs. control P = 0.643; follow up vs. control P = 0.806). INS does not cause a false positive sweat test. Further studies should be done to objectively assess the conditions that have been reported to affect sweat chloride concentrations. © 2015 Wiley Periodicals, Inc.
Terry, N P
2000-01-01
There are three areas of potential legal exposure for an organization such as a trustmark authority involved in e-health quality rating. First, an e-health provider may make a complaint about negative or impliedly negative ratings rendered by the ratings body (false negative). Typically, a negative ratings complaint would rely on defamation or product disparagement causes of action. In some cases such complaints could be defended on the basis of absence of malice (US). Second, the rating body might render a positive rating on e-health data that a third party allegedly relied upon and suffered injury (false positive). While the primary cause of action would be against the e-health data provider, questions may arise as to the possible liability of the trustmark authority. For example, some US liability exposure is possible based on cases involving the potential liability of product warrantors, trade associations, and certifiers or endorsers. Third, a ratings body may face public law liability for its own web misfeasance. Several risk management approaches are possible and would not necessarily be mutually exclusive. These approaches will require careful investigation to assess their risk reduction potential and, in some cases, the introduction of legislation.
There was not, they did not: May negation cause the negated ideas to be remembered as existing?
2017-01-01
In this article we demonstrate that negation of ideas can have paradoxical effects, possibly leading the listener to believe that the negated ideas actually existed. In Experiment 1, participants listened to a description of a house, in which some objects were mentioned, some were negated, and some were not mentioned at all. When questioned about the existence of these objects a week later, the participants gave more false positives for items that were negated in the original material than for items that were not mentioned at all, an effect we call negation related false memories (NRFM). The NRFM effect was replicated again in Experiment 2 with a sample of five and six year-old children. Experiment 3 confirmed NRFM in the case of negated actions. The results are discussed in terms of retention hypothesis, as well as the theory that negation can activate a representation of an entity and behaviour. It is also indicated that future research is needed to ensure that it is indeed negation which caused false alarms, not merely mentioning an object. PMID:28448549
Rutegård, Martin; Kverneng Hultberg, Daniel; Angenete, Eva; Lydrup, Marie-Louise
2017-12-01
The causes and effects of anastomotic leakage after anterior resection are difficult to study in small samples and have thus been evaluated using large population-based national registries. To assess the accuracy of such research, registries should be validated continuously. Patients who underwent anterior resection for rectal cancer during 2007-2013 in 15 different hospitals in three healthcare regions in Sweden were included in the study. Registry data and information from patient records were retrieved. Registered anastomotic leakage within 30 postoperative days was evaluated, using all available registry data and using only the main variable anastomotic insufficiency. With the consensus definition of anastomotic leakage developed by the International Study Group on Rectal Cancer as reference, validity measures were calculated. Some 1507 patients were included in the study. The negative and positive predictive values for registered anastomotic leakage were 96 and 88%, respectively, while the κ-value amounted to 0.76. The false-negative rate was 29%, whereas the false-positive rate reached 1.3% (the vast majority consisting of actual leaks, but occurring after postoperative day 30). Using the main variable anastomotic insufficiency only, the false-negative rate rose to 41%. There is considerable underreporting of anastomotic leakage after anterior resection for rectal cancer in the Swedish Colorectal Cancer Registry. It is probable that this causes an underestimation of the true effects of leakage on patient outcomes, and further quality control is needed.
Paige F.B. Ferguson; Michael J. Conroy; Jeffrey Hepinstall-Cymerman; Nigel Yoccoz
2015-01-01
False positive detections, such as species misidentifications, occur in ecological data, although many models do not account for them. Consequently, these models are expected to generate biased inference.The main challenge in an analysis of data with false positives is to distinguish false positive and false negative...
Substances that interfere with guaiac card tests: implications for gastric aspirate testing.
Gogel, H K; Tandberg, D; Strickland, R G
1989-09-01
Previous studies have shown that acidic pH and several ingestible substances can cause misleading guaiac tests of gastric aspirates. In this in vitro study, over 100 foods, beverages, and drugs were diluted to concentrations potentially present in the stomachs of outpatients being evaluated for gastrointestinal bleeding. These were mixed with known concentrations of blood and tested with different brands of guaiac cards. Decreased guaiac test sensitivity was associated with activated charcoal, dimethylaminoethanol, red chile, N-acetylcysteine, rifampin, red Jell-O (General Foods Corp, White Plains, NY), orange juice, Pepto-Bismol (Norwich Eaton Pharmaceuticals, Norwich, NY), simethicone, spaghetti sauce, and several red wines. Chlorophyll and methylene blue-containing tablets produced false-positive results, but other blue and blue-green colored tablets did not, except at high concentrations. Previously described false-negative results with vitamin C, bile, and certain antacids were confirmed, as were false-positive results with iodide, bromide, cupric sulfate, iron salts, and hypochlorite. Physicians should exercise caution when interpreting guaiac card tests of gastric aspirates, especially in the outpatient setting.
Interferences on microbial inhibitor tests related to ivermectin treatment in lactating dairy goats.
Romero, Tamara; Moya, Vicente Javier; Fernández, Nemesio; Althaus, Rafael; Reybroeck, Wim; Molina, María Pilar
2016-08-01
This Research Communication reports interferences related to the administration of ivermectin in lactating dairy goats on the response of microbial tests for screening antibiotics in milk. Twenty-eight Murciano-Granadina goats, naturally infested with Sarcoptes scabiei var. caprae, were treated with a subcutaneous injection of ivermectin (200 µg/kg b.w.). To prevent re-infestation, a second dose was applied 7 d later. Individual milk samples were collected, daily, up to 15 d post-treatment. Milk samples were analysed by microbial inhibitor tests (BRT MRL, Delvotest SP-NT MCS and Eclipse 100) and ivermectin residues were quantified by HPLC. A large number of positive results were obtained for all microbial tests, especially on the first day after treatment (BRT MRL = 46·4%; Delvotest SP-NT MCS = 14·3%; and Eclipse 100 = 17·8%). However, the highest concentration of drug residues in milk (24·3 ng/ml) was detected on the tenth day after treatment, when positive outcomes were relatively lower (BRT MRL = 17·8%; Delvotest SP-NT MCS = 10·7%; and Eclipse 100 = 7·4%). Results herein suggest that factors related to the ivermectin treatment other than drug residues in milk, or alterations produced by the parasitic disease itself affecting the immune response of animals, could be the cause of false-positive results in microbial tests. It can be concluded that the application of ivermectin in dairy goats infested with sarcoptes mange during lactation produces persistent drug residues in milk, and could also cause false-positive results in microbial inhibitor tests for screening antibiotics.
Urine drug screens: Considerations for the psychiatric pharmacist
Hale, Genevieve M.; Ross, Clint
2016-01-01
Introduction: Proper psychiatric evaluation of patients necessitates that the clinician be vigilant in ruling out secondary causes of symptoms, such as substance-induced symptoms. Immunoassay-type urine drug screens (UDSs) offer clinicians rapid drug screen results, ease of use, and inexpensive cost. Unfortunately, these screens are not without their limitations. This review aims to outline the nuances and limitations of immunoassay UDSs and to provide the clinician with information that facilitates more accurate interpretation of UDS results. Specifically, false positive results associated with psychiatric medications and the availability and methods for acquisition of commercialized UDS masking agents will be reviewed. Methods: A literature review was conducted to identify false positive UDSs associated with psychiatric medications. References for each article identified were also reviewed. Additionally, a Google® search was conducted to identify commercially available preparations used to mask UDS results and the methods of acquisition of these products. Results: A total of 14 articles were identified using PubMed. No articles for mood stabilizing agents were identified. Entering the phrase how to pass a drug test into Google® search yielded about 12.6 million results, and select references were reviewed based on relevance and user reviews. Discussion: Several psychiatric medications are documented as potential sources of false positive UDSs. Additionally, several agents are available for consumer purchase that may result in false negative UDSs. The clinician must be vigilant in interpreting immunoassay UDS results and should utilize more advanced forms of testing as clinically appropriate.
Arndt, Torsten; Grüner, Joachim; Schröfel, Stefanie; Stemmerich, Karsten
2012-11-30
Urine ethyl glucuronide (EtG) is considered as a specific marker of recent ethanol consumption. We describe false-positive DRI(®) EIA EtG enzyme immunoassay results caused by propyl glucuronides in urine after using a propanol-based hand sanitizer. EtG screening was done with the DRI(®) EIA EtG assay (Microgenics), using a cut-off of 0.5 mg/L as recommended by the manufacturer and of 0.1 mg/L as demanded by the German Regulations for Reissuing Drivers Licenses. Confirmatory EtG analysis was done with the ClinMass(®) EtG LC-MS/MS testkit (Recipe), extended by the mass transitions 235.1→75.1, 235.1→85.1, and 235.1→113.1 for the detection of the 1- and 2-propyl glucuronides. Self-experiments were done by staff members of our lab (n=7), using 3 mL Sterillium(®) Classic Pure (30 g/100 g 1-propanol and 45 g/100 g 2-propanol) for hand sanitation every quarter of an hour for 8 h according to DIN EN 1500:2011-05 with and without an exhauster and by passive inhalation of the sanitizer vapor. Spot urine samples were taken immediately before and up to 24 h after the first sanitizer use. False-positive immunoassay results of up to 4 mg/L or 2.3 mg/g creatinine were obtained after normal use of the sanitizer and also after passive inhalation of the sanitizer vapor (up to 0.89 mg/L or 0.61 mg/g). Immunoassay results were positive even after 4-fold use of the sanitizer (up to 0.14 mg/L or 0.38 mg/g) and up to 6 h after the last sanitizer contact (maximum 0.63 mg/L and 0.33 mg/g for sanitizer users and 0.25 mg/g after passive inhalation). Spiking of EtG-free urine with 1-propyl glucuronide (Athena Environmental Sciences) between 0.05 and 10 mg/L clearly demonstrated a cross reaction of the immunoassay of approx. 10% as compared to EtG. LC-MS/MS of urines with a positive immunoassay EtG result did not show EtG signals, but distinct signals of 1-propyl glucuronide (n-propyl glucuronide) and 2-propyl glucuronide (iso-propyl glucuronide). An exhauster effectively prevented the inhalation of the sanitizer vapor, the formation of propyl glucuronides and thus false-positive DRI(®) EIA EtG screening results, proving that propyl alcohols are almost exclusively taken up by respiration. The widespread use of propanol-containing products such as hand sanitizers may lead to sufficient uptake of propyl alcohols and excretion of significant amounts of propyl glucuronides to yield false-positive DRI(®) EIA EtG screening results. Thus, positive EtG immunoassay results have to be controlled by mass-spectrometry, in clinical cases at least if ethanol intake is denied by the patient. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Clinical experience with (/sup 111/ In) indium chloride scanning in inflammatory diseases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dayem, H.M.; Breen, J.; Leslie, E.V.
1978-05-01
Forty-eight patients were scanned with /sup 111/In-chloride in an attempt to identify the cause of fever. Fifteen true positive scans, 30 true negatives, and 3 false negatives were found. Of the 15 true positives, 7 cases of abdominal or pelvic abscess, and 8 cases of alcoholic hepatitis were detected. The 3 false negatives included: (1) an abscess in the anterior abdominal wall; (2) an abscess in the right upper quadrant at the site of a necrotic gallbladder; and (3) a tuberculous abscess of the lumbar spine. Examples from the different categories, pitfalls in interpretation and advantages and disadvantages of scanningmore » with /sup 111/In-chloride will be presented. These studies indicate that /sup 111/In-chloride is a safe, reliable scanning agent for abscesses below the diaphragm especially in patients who cannot undergo adequate bowel preparation.« less
He, Dengchao; Zhang, Hongjun; Hao, Wenning; Zhang, Rui; Cheng, Kai
2017-07-01
Distant supervision, a widely applied approach in the field of relation extraction can automatically generate large amounts of labeled training corpus with minimal manual effort. However, the labeled training corpus may have many false-positive data, which would hurt the performance of relation extraction. Moreover, in traditional feature-based distant supervised approaches, extraction models adopt human design features with natural language processing. It may also cause poor performance. To address these two shortcomings, we propose a customized attention-based long short-term memory network. Our approach adopts word-level attention to achieve better data representation for relation extraction without manually designed features to perform distant supervision instead of fully supervised relation extraction, and it utilizes instance-level attention to tackle the problem of false-positive data. Experimental results demonstrate that our proposed approach is effective and achieves better performance than traditional methods.
Daluwatte, Chathuri; Vicente, Jose; Galeotti, Loriano; Johannesen, Lars; Strauss, David G; Scully, Christopher G
Performance of ECG beat detectors is traditionally assessed on long intervals (e.g.: 30min), but only incorrect detections within a short interval (e.g.: 10s) may cause incorrect (i.e., missed+false) heart rate limit alarms (tachycardia and bradycardia). We propose a novel performance metric based on distribution of incorrect beat detection over a short interval and assess its relationship with incorrect heart rate limit alarm rates. Six ECG beat detectors were assessed using performance metrics over long interval (sensitivity and positive predictive value over 30min) and short interval (Area Under empirical cumulative distribution function (AUecdf) for short interval (i.e., 10s) sensitivity and positive predictive value) on two ECG databases. False heart rate limit and asystole alarm rates calculated using a third ECG database were then correlated (Spearman's rank correlation) with each calculated performance metric. False alarm rates correlated with sensitivity calculated on long interval (i.e., 30min) (ρ=-0.8 and p<0.05) and AUecdf for sensitivity (ρ=0.9 and p<0.05) in all assessed ECG databases. Sensitivity over 30min grouped the two detectors with lowest false alarm rates while AUecdf for sensitivity provided further information to identify the two beat detectors with highest false alarm rates as well, which was inseparable with sensitivity over 30min. Short interval performance metrics can provide insights on the potential of a beat detector to generate incorrect heart rate limit alarms. Published by Elsevier Inc.
Dental pulp neurophysiology: part 2. Current diagnostic tests to assess pulp vitality.
Abd-Elmeguid, Ashraf; Yu, Donald C
2009-03-01
In this second part of our 2-part review, we discuss recent research about pulp tests that determine the vitality of the tooth and clinically accepted pulp testers. A pain response to hot, cold or an electric pulp tester indicates the vitality of only a tooth's pulpal sensory supply; the response does not give any idea about the state of the pulp. Although the sensitivity of these tests is high, when false-positive and false-negative results occur, they may affect the treatment of the tooth. A tooth falsely diagnosed as nonvital with an electric pulp tester may undergo an unnecessary root canal, whereas one falsely diagnosed as vital may be left untreated, causing the necrotic tissue to destroy the supporting tissues (resorption). The vascular supply is more important to the determination of the health of the pulp than the sensory supply. Pulp death is caused by cessation of blood flow and may result in a necrotic pulp, even though the pulpal sensory supply may still be viable. The pulp can be healed only if the circulating blood flow is healthy. Although still under investigation, diagnostic devices that examine pulpal blood flow, such as the pulse oximeter and laser Doppler flowmetry, show promising results for the assessment of pulp vitality.
Pulsar Search Using Supervised Machine Learning
NASA Astrophysics Data System (ADS)
Ford, John M.
2017-05-01
Pulsars are rapidly rotating neutron stars which emit a strong beam of energy through mechanisms that are not entirely clear to physicists. These very dense stars are used by astrophysicists to study many basic physical phenomena, such as the behavior of plasmas in extremely dense environments, behavior of pulsar-black hole pairs, and tests of general relativity. Many of these tasks require a large ensemble of pulsars to provide enough statistical information to answer the scientific questions posed by physicists. In order to provide more pulsars to study, there are several large-scale pulsar surveys underway, which are generating a huge backlog of unprocessed data. Searching for pulsars is a very labor-intensive process, currently requiring skilled people to examine and interpret plots of data output by analysis programs. An automated system for screening the plots will speed up the search for pulsars by a very large factor. Research to date on using machine learning and pattern recognition has not yielded a completely satisfactory system, as systems with the desired near 100% recall have false positive rates that are higher than desired, causing more manual labor in the classification of pulsars. This work proposed to research, identify, propose and develop methods to overcome the barriers to building an improved classification system with a false positive rate of less than 1% and a recall of near 100% that will be useful for the current and next generation of large pulsar surveys. The results show that it is possible to generate classifiers that perform as needed from the available training data. While a false positive rate of 1% was not reached, recall of over 99% was achieved with a false positive rate of less than 2%. Methods of mitigating the imbalanced training and test data were explored and found to be highly effective in enhancing classification accuracy.
Iwanowicz, Deborah D; Sanders, Lakyn R; Schill, W Bane; Xayavong, Maniphet V; da Silva, Alexandre J; Qvarnstrom, Yvonne; Smith, Trevor
2015-07-01
The rat lungworm (Angiostrongylus cantonensis) is a parasitic nematode that causes rat lungworm disease. It is the leading cause of eosinophilic meningitis and is a zoonotic health risk. We confirmed the presence of A. cantonensis using species-specific, quantitative PCR in 18 of 50 (36%) giant African land snails (Lissachatina fulica) collected from Miami, Florida, US in May 2013. These snails were collected from seven of 21 core areas that the Florida Department of Agriculture and Consumer Services monitor weekly. Rat lungworms have not previously been identified in these areas. Duplicate DNA extractions of foot muscle tissue from each snail were tested. Of the seven core areas we examined, six were positive for A. cantonensis and prevalence of infection ranged from 27% to 100%. Of the 18 positive snails, only five were positive in both extractions. Our results confirm an increase in the range and prevalence of rat lungworm infection in Miami. We also emphasize the importance of extracting sufficient host tissue to minimize false negatives.
Iwanowicz, Deborah; Sanders, Lakyn R.; Schill, W. Bane; Xayavong, Maniphet V; da Silva, Alexandre J; Qvarnstrom, Yvonne; Smith, Trevor
2015-01-01
The rat lungworm (Angiostrongylus cantonensis) is a parasitic nematode that causes rat lungworm disease. It is the leading cause of eosinophilic meningitis and is a zoonotic health risk. We confirmed the presence of A. cantonensis using species-specific, quantitative PCR in 18 of 50 (36%) giant African land snails (Lissachatina fulica) collected from Miami, Florida in May 2013. These snails were collected from seven of 21 core areas that the Florida Department of Agriculture and Consumer Services monitor weekly. Rat lungworms have not previously been identified in these areas. Duplicate DNA extractions of foot muscle tissue from each snail were tested. Of the seven core areas we examined, six were positive for A. cantonensis and prevalence of infection ranged from 27% to 100%. Of the 18 positive snails, only five were positive in both extractions. Our results confirm an increase in the range and prevalence of rat lungworm infection in Miami. We also emphasize the importance of extracting sufficient host tissue to minimize false negatives.
Nelson, Christina; Hojvat, Sally; Johnson, Barbara; Petersen, Jeannine; Schriefer, Marty; Beard, C Ben; Petersen, Lyle; Mead, Paul
2014-04-18
In 2005, CDC and the Food and Drug Administration (FDA) issued a warning regarding the use of Lyme disease tests whose accuracy and clinical usefulness have not been adequately established. Often these are laboratory-developed tests (also known as "home brew" tests) that are manufactured and used within a single laboratory and have not been cleared or approved by FDA. Recently, CDC has received inquiries regarding a laboratory-developed test that uses a novel culture method to identify Borrelia burgdorferi, the spirochete that causes Lyme disease. Patient specimens reportedly are incubated using a two-step pre-enrichment process, followed by immunostaining with or without polymerase chain reaction (PCR) analysis. Specimens that test positive by immunostaining or PCR are deemed "culture positive". Published methods and results for this laboratory-developed test have been reviewed by CDC. The review raised serious concerns about false-positive results caused by laboratory contamination and the potential for misdiagnosis.
Cross-Reactivity of Chloroquine and Hydroxychloroquine With DRI Amphetamine Immunoassay.
Gomila, Isabel; Quesada, Loreto; López-Corominas, Victoria; Fernández, Julia; Servera, Miguel Á; Sahuquillo, Laura; Dastis, Macarena; Torrents, Albert; Barceló, Bernardino
2017-04-01
Chloroquine and hydroxychloroquine are medical drugs used to treat the chemoprophylaxis of malaria and a second-line anti-inflammatory drug. We performed a study of cross-reactivity of chloroquine and hydroxychloroquine in the DRI Amphetamine Assay inspired by a case report of a self-ingestion of chloroquine after a family dispute, that involved the following: (1) an in vitro study with control samples of healthy subjects, (2) an in vivo study with samples of patients with rheumatoid arthritis, and (3) an evaluation of the cross-reactivity of chloroquine and hydroxychloroquine in 3 additional immunoassays. In the case report, the Amphetamine DRI assay resulted positive both at 1000 ng/mL cutoff (1507 and 1137 ng/mL) and at 500 ng/mL cutoff (1178 and 642 ng/mL). Chloroquine urine levels were 103,900 and 100,900 ng/mL at 5 and 9 hours after ingestion. The results with control samples showed a positive cross-reactivity of chloroquine in the DRI Amphetamine Assay (approximately 0.74% and 0.89% at cutoff of 1000 and 500 ng/mL, respectively). Hydroxychloroquine did not cross-react with the DRI Amphetamine Assay up to 1,000,000 ng/mL. In patients treated with chloroquine or hydroxychloroquine, DRI Amphetamine did not produce false-positive results. The comparative assay study showed a positive cross-reactivity of chloroquine in the Emit II Plus Amphetamines Assay with control samples. Chloroquine can cause false-positive results in the DRI Amphetamine Assay when it is present at high concentrations. Hydroxychloroquine did not produce false-positive results neither in the DRI Amphetamine Assay nor in the others immunoassays evaluated.
Unreliable alcohol testing in a shipping safety programme.
Helander, Anders; Hagelberg, Charlotte Asker; Beck, Olof; Petrini, Björn
2009-08-10
Within a maritime alcohol and drug testing programme, a case showing an unphysiological urine ethanol concentration (235 mmol/L, 10.8 g/L) was found. The sample contained low levels of the ethanol metabolites ethyl glucuronide (EtG) and ethyl sulphate (EtS) which confirmed prior drinking, but also tested positive for the fermenting yeast Candida albicans which suggested post-sampling ethanol formation. This and other questionable cases prompted investigation of the suitability of urine alcohol testing for the intended application. Besides the routine measurements of ethanol, illicit drugs and creatinine, randomly selected ethanol-positive and ethanol-negative urines collected within the maritime programme were checked for the presence of EtG and EtS and for fungal and bacterial growth. Data on sample handling and storage was also gathered. Ten of 15 (67%) ethanol-positive and 4 of 9 (44%) ethanol-negative urines contained yeast and/or bacteria. Among the ethanol-positive cases, 4 (27%) were obviously false positives because EtG and EtS were not detected. Microbial action as the reason for false-high ethanol concentrations was indicated in other cases. When 17 bacteria-infected but fungi-negative urines were supplemented with glucose and stored for 1 week at 21 degrees C, ethanol was formed in 2 specimens containing Escherichia coli and E. coli plus P. aeruginosa. In these samples, EtG was also formed on storage while EtS was not. The routines employed for urine collection and handling within this substance abuse programme caused many false-positive identifications of alcohol use with unintended medico-legal consequences. Unpreserved urines stored without cooling should not be used for alcohol testing, given the high risk for microbial interference.
Texture-based CAD improves diagnosis for low-dose CT colonography
NASA Astrophysics Data System (ADS)
Liang, Zhengrong; Cohen, Harris; Posniak, Erica; Fiore, Eddie; Wang, Zigang; Li, Bin; Andersen, Joseph; Harrington, Donald
2008-03-01
Computed tomography (CT)-based virtual colonoscopy or CT colonography (CTC) currently utilizes oral contrast solutions to tag the colonic fluid and possibly residual stool for differentiation from the colon wall and polyps. The enhanced image density of the tagged colonic materials causes a significant partial volume (PV) effect into the colon wall as well as the lumen space (filled with air or CO II). The PV effect on the colon wall can "bury" polyps of size as large as 5mm by increasing their image densities to a noticeable level, resulting in false negatives. It can also create false positives when PV effect goes into the lumen space. We have been modeling the PV effect for mixture-based image segmentation and developing text-based computer-aided detection of polyp (CADpolyp) by utilizing the PV mixture-based image segmentation. This work presents some preliminary results of developing and applying texture-based CADpolyp technique to low-dose CTC studies. A total of 114 studies of asymptomatic patients older than 50, who underwent CTC and then optical colonoscopy (OC) on the same day, were selected from a database, which was accumulated in the past decade and contains various bowel preparations and CT scanning protocols. The participating radiologists found ten polyps of greater than 5 mm from a total of 16 OC proved polyps, i.e., a detection sensitivity of 63%. They scored 23 false positives from the database, i.e., a 20% false positive rate. Approximately 70% of the datasets were marked as imperfect bowel cleansing and/or presence of image artifacts. The impact of imperfect bowel cleansing and image artifacts on VC performance is significant. The texture-based CADpolyp detected all the polyps with an average of 2.68 false positives per patient. This indicates that texture-based CADpolyp can improve the CTC performance in the cases of imperfect cleansed bowels and presence of image artifacts.
Discrepancy between culture and DNA probe analysis for the detection of periodontal bacteria.
van Steenbergen, T J; Timmerman, M F; Mikx, F H; de Quincey, G; van der Weijden, G A; van der Velden, U; de Graaff, J
1996-10-01
The purpose of this study was to compare a commercially available DNA probe technique with conventional cultural techniques for the detection of Actinobacillus actinomycetemcomitans, Porphyromonas gingivalis and Prevotella intermedia in subgingival plaque samples. Samples from 20 patients with moderate to severe periodontitis were evaluated at baseline and during a 15 months period of periodontal treatment. Paperpoints from 4 periodontal pockets per patient were forwarded to Omnigene for DNA probe analysis, and simultaneously inserted paperpoints from the same pockets were analyzed by standard culture techniques. In addition, mixed bacterial samples were constructed harbouring known proportions of 25 strains of A. actinomycetemcomitans, P. gingivalis and P. intermedia each. A relatively low concordance was found between both methods. At baseline a higher detection frequency was found for A. actinomycetemcomitans and P. gingivalis for the DNA probe technique; for P. intermedia the detection frequency by culture was higher. For A. actinomycetemcomitans, 21% of the culture positive samples was positive with the DNA probe. Testing the constructed bacterial samples with the DNA probe method resulted in about 16% false positive results for the 3 species tested. Furthermore, 40% of P. gingivalis strains were not detected by the DNA probe. The present data suggest that at least part of the discrepancies found between the DNA probe technique used and cultural methods are caused by false positive and false negative DNA probe results. Therefore, the value of this DNA probe method for the detection of periodontal pathogens is questionable.
Bupropion interference with immunoassays for amphetamines and LSD.
Vidal, Christian; Skripuletz, Thomas
2007-06-01
A 50-year-old male patient suddenly had lost consciousness, although he had previously been healthy. On arrival at hospital seizures arose. The authors investigated a urine sample of the patient, and performed toxicological drug screening with immunochemical Cloned Enzyme Donor Immunoassay (CEDIA) assays. Positive findings for amphetamines and LSD could not be confirmed. Using gas chromatography/mass spectrometry (GC/MS), and liquid chromatography/mass spectrometry (LC/MS), the authors identified bupropion, a drug used to aid in smoking cessation, as the interfering compound, which may cause false-positive results for amphetamines and LSD using the CEDIA assays.
Use of an Atrial Lead with Very Short Tip-To-Ring Spacing Avoids Oversensing of Far-Field R-Wave
Kolb, Christof; Nölker, Georg; Lennerz, Carsten; Jetter, Hansmartin; Semmler, Verena; Pürner, Klaus; Gutleben, Klaus-Jürgen; Reents, Tilko; Lang, Klaus; Lotze, Ulrich
2012-01-01
Objective The AVOID-FFS (Avoidance of Far-Field R-wave Sensing) study aimed to investigate whether an atrial lead with a very short tip-to-ring spacing without optimization of pacemaker settings shows equally low incidence of far-field R-wave sensing (FFS) when compared to a conventional atrial lead in combination with optimization of the programming. Methods Patients receiving a dual chamber pacemaker were randomly assigned to receive an atrial lead with a tip-to-ring spacing of 1.1 mm or a lead with a conventional tip-to-ring spacing of 10 mm. Postventricular atrial blanking (PVAB) was programmed to the shortest possible value of 60 ms in the study group, and to an individually determined optimized value in the control group. Atrial sensing threshold was programmed to 0.3 mV in both groups. False positive mode switch caused by FFS was evaluated at one and three months post implantation. Results A total of 204 patients (121 male; age 73±10 years) were included in the study. False positive mode switch caused by FFS was detected in one (1%) patient of the study group and two (2%) patients of the control group (p = 0.62). Conclusion The use of an atrial electrode with a very short tip-to-ring spacing avoids inappropriate mode switch caused by FFS without the need for individual PVAB optimization. Trial Registration ClinicalTrials.gov NCT00512915 PMID:22745661
Use of an atrial lead with very short tip-to-ring spacing avoids oversensing of far-field R-wave.
Kolb, Christof; Nölker, Georg; Lennerz, Carsten; Jetter, Hansmartin; Semmler, Verena; Pürner, Klaus; Gutleben, Klaus-Jürgen; Reents, Tilko; Lang, Klaus; Lotze, Ulrich
2012-01-01
The AVOID-FFS (Avoidance of Far-Field R-wave Sensing) study aimed to investigate whether an atrial lead with a very short tip-to-ring spacing without optimization of pacemaker settings shows equally low incidence of far-field R-wave sensing (FFS) when compared to a conventional atrial lead in combination with optimization of the programming. Patients receiving a dual chamber pacemaker were randomly assigned to receive an atrial lead with a tip-to-ring spacing of 1.1 mm or a lead with a conventional tip-to-ring spacing of 10 mm. Postventricular atrial blanking (PVAB) was programmed to the shortest possible value of 60 ms in the study group, and to an individually determined optimized value in the control group. Atrial sensing threshold was programmed to 0.3 mV in both groups. False positive mode switch caused by FFS was evaluated at one and three months post implantation. A total of 204 patients (121 male; age 73±10 years) were included in the study. False positive mode switch caused by FFS was detected in one (1%) patient of the study group and two (2%) patients of the control group (p = 0.62). The use of an atrial electrode with a very short tip-to-ring spacing avoids inappropriate mode switch caused by FFS without the need for individual PVAB optimization. ClinicalTrials.gov NCT00512915.
Creger, Richard J.; Weeman, Kisa E.; Jacobs, Michael R.; Morrissey, Anne; Parker, Pamela; Fox, Robert M.; Lazarus, Hillard M.
1998-01-01
We retrospectively compared the utility of a fungal isolation device (Isolator) versus conventional techniques for recovering fungal organisms from blood cultures obtained from neutropenic cancer patients. Positive cultures were deemed true pathogens, possible pathogens, or contaminants according to laboratory and clinical criteria. Fifty-three patients had 66 positive blood cultures for fungi, nine on multiple occasions. In 20 episodes true pathogens were recovered, 6 from broth medium alone, 4 from the Isolator system alone, and 10 from both systems. False-negative cultures were noted in 4 of 20 (20%) cases in which broth medium was used and in 6 of 20 (30%) cases in which the Isolator system was used. Possible pathogens were detected in 4 of 66 blood culture-positive cases. Forty-two positive cultures were considered contaminants, 1 collected from standard medium and 41 of 42 (98%) which grew only in Isolators. Eleven of 18 patients with true fungal infections expired as a result of infection, while 4 of 33 patients with a contaminant expired, none from a fungal cause. We do not advocate the routine use of Isolator tubes in the evaluation of the febrile, neutropenic patient due to the high rates of false positives and of contamination. PMID:9431970
Tsujikawa, Kenji; Yamamuro, Tadashi; Kuwayama, Kenji; Kanamori, Tatsuyuki; Iwata, Yuko T; Miyamoto, Kazuna; Kasuya, Fumiyo; Inoue, Hiroyuki
2016-09-01
This is the first report on development of a library search-based screening system for 3,4-methylenedioxymethamphetamine (MDMA) in ecstasy tablets using a portable near-infrared (NIR) spectrometer. The spectrum library consisted of spectra originating from standard substances as well as mixtures of MDMA hydrochloride (MDMA-HCl) and diluents. The raw NIR spectra were mathematically pretreated, and then, a library search was performed using correlation coefficient. To enhance the discrimination ability, the wavelength used for the library search was limited. Mixtures of MDMA-HCl and diluents were used to decide criteria to judge MDMA-positive or MDMA-negative. Confiscated MDMA tablets and medicinal tablets were used for performance check of the criteria. Twenty-two of 27 MDMA tablets were truly judged as MDMA-positive. Five false-negative results may be caused by compounds not included in the library. No false-positive results were obtained for medicinal tablets. This system will be a useful tool for on-site screening of MDMA tablets. © 2016 American Academy of Forensic Sciences.
Hardie, Diana Ruth; Korsman, Stephen N; Hsiao, Nei-Yuan; Morobadi, Molefi Daniel; Vawda, Sabeehah; Goedhals, Dominique
2017-01-01
In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector laboratories, the performance of two automated platforms was compared in a clinical pathology setting, firstly on routine diagnostic specimens and secondly on known sero-negative samples. Firstly, 1181 routine diagnostic specimens were sequentially tested on Siemens and Roche automated 4th generation platforms. HIV viral load, western blot and follow up testing were used to determine the true status of inconclusive specimens. Subsequently, known HIV seronegative samples from a single donor were repeatedly tested on both platforms and an analyser was tested for surface contamination with HIV positive serum to identify how suspected specimen contamination could be occurring. Serial testing of diagnostic specimens yielded 163 weakly positive or discordant results. Only 3 of 163 were conclusively shown to indicate true HIV infection. Specimen contamination with HIV antibody was suspected, based on the following evidence: the proportion of positive specimens increased on repeated passage through the analysers; viral loads were low or undetectable and western blots negative or indeterminate on problem specimens; screen negative, 2nd test positive specimens tested positive when reanalysed on the screening assay; follow up specimens (where available) were negative. Similarly, an increasing number of known negative specimens became (repeatedly) sero-positive on serial passage through one of the analysers. Internal and external analyser surfaces were contaminated with HIV serum, evidence that sample splashes occur during testing. Due to the extreme sensitivity of these assays, contamination with minute amounts of HIV antibody can cause a negative sample to test positive. Better contamination control measures are needed on analysers used in clinical pathology environments, especially in regions where HIV sero-prevalence is high.
Statistical approaches to account for false-positive errors in environmental DNA samples.
Lahoz-Monfort, José J; Guillera-Arroita, Gurutzeta; Tingley, Reid
2016-05-01
Environmental DNA (eDNA) sampling is prone to both false-positive and false-negative errors. We review statistical methods to account for such errors in the analysis of eDNA data and use simulations to compare the performance of different modelling approaches. Our simulations illustrate that even low false-positive rates can produce biased estimates of occupancy and detectability. We further show that removing or classifying single PCR detections in an ad hoc manner under the suspicion that such records represent false positives, as sometimes advocated in the eDNA literature, also results in biased estimation of occupancy, detectability and false-positive rates. We advocate alternative approaches to account for false-positive errors that rely on prior information, or the collection of ancillary detection data at a subset of sites using a sampling method that is not prone to false-positive errors. We illustrate the advantages of these approaches over ad hoc classifications of detections and provide practical advice and code for fitting these models in maximum likelihood and Bayesian frameworks. Given the severe bias induced by false-negative and false-positive errors, the methods presented here should be more routinely adopted in eDNA studies. © 2015 John Wiley & Sons Ltd.
Cole, Laurence A; Khanlian, Sarah A
2004-05-01
False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.
Bond, Mary; Garside, Ruth; Hyde, Christopher
2015-11-01
To understand the meaning of having a false-positive screening mammogram. Qualitative interview study. Twenty-one women, who had experienced false-positive screening mammograms, took part in semi-structured interviews that were analysed with Interpretive Phenomenological Analysis. This research took place in the United Kingdom. The analysis revealed a wide range of response to having a false-positive mammogram, from nonchalance to extreme fear. These reactions come from the potential for the belief that one is healthy to be challenged by being recalled, as the worst is frequently assumed. For most, the image of the lesion on the X-ray brought the reality of this challenge into sharp focus, as they might soon discover they had breast cancer. Waiting, whether for the appointment, at the clinic or for biopsy results was considered the worst aspect of being recalled. Generally, the uncertainty was quickly resolved with the pronouncement of the 'all-clear', which brought considerable relief and the restoration of belief in the healthy self. However, for some, lack of information, contradictory information, or poor interpersonal communication meant that uncertainty about their health status lingered at least until their next normal screening mammogram. Mammography screening related anxiety lasted for up to 12 years. Breast cancer screening produces a 'crisis of visibility'. Accepting the screening invitation is taking a risk that you may experience unnecessary stress, uncertainty, fear, anxiety, and physical pain. Not accepting the invitation is taking a risk that malignant disease will remain invisible. Statement of contribution What is already known on this subject? More than 50,000 women a year in England have a false-positive mammogram (FPM). Having an FPM can cause anxiety compared with a normal mammogram. The anxiety can last up to 35 months. What does this study add? Refocuses attention from the average response found in quantitative studies to the wide range of individual response. Gives insight into the nature of the anxiety of having FPMs. Highlights the role of uncertainty in provoking distress from an FPM. © 2015 The British Psychological Society.
An Assessment of Normalized Difference Skin Index Robustness in Aquatic Environments
2014-03-27
Index NDSI Normalized Difference Skin Index NDVI Normalized Difference Vegetation Index NIR Near-Infrared SAR Search and Rescue SERG Sensors... Vegetation and water-bearing objects with high scatter tend to have NDSI values similar to human skin , potentially causing false positives in certain...AN ASSESSMENT OF NORMALIZED DIFFERENCE SKIN INDEX ROBUSTNESS IN AQUATIC ENVIRONMENTS THESIS Alice W. Chan, First Lieutenant, USAF AFIT-ENG-14-M-17
A Closer Look at Self-Reported Suicide Attempts: False Positives and False Negatives
ERIC Educational Resources Information Center
Ploderl, Martin; Kralovec, Karl; Yazdi, Kurosch; Fartacek, Reinhold
2011-01-01
The validity of self-reported suicide attempt information is undermined by false positives (e.g., incidences without intent to die), or by unreported suicide attempts, referred to as false negatives. In a sample of 1,385 Austrian adults, we explored the occurrence of false positives and false negatives with detailed, probing questions. Removing…
ERIC Educational Resources Information Center
Greyson, Bruce
2005-01-01
Some persons who claim to have had near-death experiences (NDEs) fail research criteria for having had NDEs ("false positives"); others who deny having had NDEs do meet research criteria for having had NDEs ("false negatives"). The author evaluated false positive claims and false negative denials in an organization that promotes near-death…
Comparison of the accuracy rates of 3-T and 1.5-T MRI of the knee in the diagnosis of meniscal tear.
Grossman, Jeffrey W; De Smet, Arthur A; Shinki, Kazuhiko
2009-08-01
The purpose of this study was to compare the accuracy of 3-T MRI with that of 1.5-T MRI of the knee in the diagnosis of meniscal tear and to analyze the causes of diagnostic error. We reviewed the medical records and original MRI interpretations of 100 consecutive patients who underwent 3-T MRI of the knee and of 100 consecutive patients who underwent 1.5-T MRI of the knee to determine the accuracy of diagnoses of meniscal tear. Knee arthroscopy was the reference standard. We retrospectively reviewed all MRI diagnostic errors to determine the cause of the errors. At arthroscopy, 109 medial and 77 lateral meniscal tears were identified in the 200 patients. With two abnormal MR images indicating a meniscal tear, the sensitivity and specificity for medial tear were 92.7% and 82.2% at 1.5-T MRI and 92.6% and 76.1% at 3-T MRI (p = 1.0, p = 0.61). The sensitivity and specificity for lateral tears were 68.4% and 95.2% at 1.5-T MRI and 69.2% and 91.8% at 3-T MRI (p = 1.0, p = 0.49). Of the false-positive diagnoses of medial meniscal tear, five of eight at 1.5 T and seven of 11 at 3 T were apparent peripheral longitudinal tears of the posterior horn. Fifteen of the 26 missed medial and lateral meniscal tears were not seen in retrospect even with knowledge of the tear type and location. Allowing for sample size limitations, we found comparable accuracy of 3-T and 1.5-T MRI of the knee in the diagnosis of meniscal tear. The causes of false-positive and false-negative MRI diagnoses of meniscal tear are similar for 3-T and 1.5-T MRI.
Risk of breast cancer after false-positive results in mammographic screening.
Román, Marta; Castells, Xavier; Hofvind, Solveig; von Euler-Chelpin, My
2016-06-01
Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level data from the population-based screening programs in Copenhagen and Funen in Denmark, Norway, and Spain. Overall, 150,383 screened women from Denmark (1991-2008), 612,138 from Norway (1996-2010), and 1,172,572 from Spain (1990-2006) were included. Poisson regression was used to estimate the relative risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50-69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1.4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93-2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77-1.96), whereas those who tested false-positive at third screening had a RR of 2.42 (95% CI: 2.21-2.64). The RR of breast cancer at the screening test after the false-positive result was 3.95 (95% CI: 3.71-4.21), whereas it decreased to 1.25 (95% CI: 1.17-1.34) three or more screens after the false-positive result. Women with false-positive results had a twofold risk of screen-detected breast cancer compared to women with negative tests. The risk remained significantly higher three or more screens after the false-positive result. The increased risk should be considered when discussing stratified screening strategies. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
Schwartz, Lisa M; Woloshin, Steven; Sox, Harold C; Fischhoff, Baruch; Welch, H Gilbert
2000-01-01
Objective To determine women's attitudes to and knowledge of both false positive mammography results and the detection of ductal carcinoma in situ after screening mammography. Design Cross sectional survey. Setting United States. Participants 479 women aged 18-97 years who did not report a history of breast cancer. Main outcome measures Attitudes to and knowledge of false positive results and the detection of ductal carcinoma in situ after screening mammography. Results Women were aware that false positive results do occur. Their median estimate of the false positive rate for 10 years of annual screening was 20% (25th percentile estimate, 10%; 75th percentile estimate, 45%). The women were highly tolerant of false positives: 63% thought that 500 or more false positives per life saved was reasonable and 37% would tolerate 10 000 or more. Women who had had a false positive result (n=76) expressed the same high tolerance: 39% would tolerate 10 000 or more false positives. 62% of women did not want to take false positive results into account when deciding about screening. Only 8% of women thought that mammography could harm a woman without breast cancer, and 94% doubted the possibility of non-progressive breast cancers. Few had heard about ductal carcinoma in situ, a cancer that may not progress, but when informed, 60% of women wanted to take into account the possibility of it being detected when deciding about screening. Conclusions Women are aware of false positives and seem to view them as an acceptable consequence of screening mammography. In contrast, most women are unaware that screening can detect cancers that may never progress but feel that such information would be relevant. Education should perhaps focus less on false positives and more on the less familiar outcome of detection of ductal carcinoma in situ. PMID:10856064
Deindl, Philipp; O'Reilly, Megan; Zoller, Katharina; Berger, Angelika; Pollak, Arnold; Schwindt, Jens; Schmölzer, Georg M
2014-01-01
Anatomical face mask with an air cushion rim might be placed accidentally in a false orientation on the newborn's face or filled with various amounts of air during neonatal resuscitation. Both false orientation as well as variable filling may reduce a tight seal and therefore hamper effective positive pressure ventilation (PPV). We aimed to measure the influence of mask type and mask position on the effectiveness of PPV. Twenty neonatal staff members delivered PPV to a modified, leak-free manikin. Resuscitation parameters were recorded using a self-inflatable bag PPV with an Intersurgical anatomical air cushion rim face mask (IS) and a size 0/1 Laerdal round face mask. Three different positions of the IS were tested: correct position, 90° and 180° rotation in reference to the midline of the face. IS masks in each correct position on the face but with different inflation of the air cushion (empty, 10, 20 and 30 mL). Mask leak was similar with mask rotation to either 90° or 180° but significantly increased from 27 (13-73) % with an adequate filled IS mask compared to 52 (16-83) % with an emptied air cushion rim. Anatomical-shaped face mask had similar mask leaks compared to round face mask. A wrongly positioned anatomical-shaped mask does not influence mask leak. Mask leak significantly increased once the air cushion rim was empty, which may cause failure in mask PPV.
Presymptomatic Diagnosis of Spinal Muscular Atrophy Through Newborn Screening.
Chien, Yin-Hsiu; Chiang, Shu-Chuan; Weng, Wen-Chin; Lee, Ni-Chung; Lin, Ching-Jie; Hsieh, Wu-Shiun; Lee, Wang-Tso; Jong, Yuh-Jyh; Ko, Tsang-Ming; Hwu, Wuh-Liang
2017-11-01
To demonstrate the feasibility of presymptomatic diagnosis of spinal muscular atrophy (SMA) through newborn screening (NBS). We performed a screening trial to assess all newborns who underwent routine newborn metabolic screening at the National Taiwan University Hospital newborn screening center between November 2014 and September 2016. A real-time polymerase chain reaction (RT-PCR) genotyping assay for the SMN1/SMN2 intron 7 c.888+100A/G polymorphism was performed to detect homozygous SMN1 deletion using dried blood spot (DBS) samples. Then the exon 7 c.840C>T mutation and SMN2 copy number were determined by both droplet digital PCR (ddPCR) using the original screening DBS and multiplex ligation-dependent probe amplification (MLPA) using a whole blood sample. Of the 120 267 newborns, 15 tested positive according to the RT-PCR assay. The DBS ddPCR assay excluded 8 false-positives, and the other 7 patients were confirmed by the MLPA assay. Inclusion of the second-tier DBS ddPCR screening assay resulted in a positive prediction value of 100%. The incidence of SMA was 1 in 17 181 (95% CI, 1 in 8323 to 1 in 35 468). Two of the 3 patients with 2 copies of SMN2 and all 4 patients with 3 or 4 copies of SMN2 were asymptomatic at the time of diagnosis. Five of the 8 false-positives were caused by intragenic recombination between SMN1 and SMN2. Newborn screening can detect patients affected by SMA before symptom onset and enable early therapeutic intervention. A combination of a RT-PCR and a second-tier ddPCR can accurately diagnose SMA from DBS samples with no false-positives. ClinicalTrials.gov NCT02123186. Copyright © 2017 Elsevier Inc. All rights reserved.
Wang, Sheng H; Lobier, Muriel; Siebenhühner, Felix; Puoliväli, Tuomas; Palva, Satu; Palva, J Matias
2018-06-01
Inter-areal functional connectivity (FC), neuronal synchronization in particular, is thought to constitute a key systems-level mechanism for coordination of neuronal processing and communication between brain regions. Evidence to support this hypothesis has been gained largely using invasive electrophysiological approaches. In humans, neuronal activity can be non-invasively recorded only with magneto- and electroencephalography (MEG/EEG), which have been used to assess FC networks with high temporal resolution and whole-scalp coverage. However, even in source-reconstructed MEG/EEG data, signal mixing, or "source leakage", is a significant confounder for FC analyses and network localization. Signal mixing leads to two distinct kinds of false-positive observations: artificial interactions (AI) caused directly by mixing and spurious interactions (SI) arising indirectly from the spread of signals from true interacting sources to nearby false loci. To date, several interaction metrics have been developed to solve the AI problem, but the SI problem has remained largely intractable in MEG/EEG all-to-all source connectivity studies. Here, we advance a novel approach for correcting SIs in FC analyses using source-reconstructed MEG/EEG data. Our approach is to bundle observed FC connections into hyperedges by their adjacency in signal mixing. Using realistic simulations, we show here that bundling yields hyperedges with good separability of true positives and little loss in the true positive rate. Hyperedge bundling thus significantly decreases graph noise by minimizing the false-positive to true-positive ratio. Finally, we demonstrate the advantage of edge bundling in the visualization of large-scale cortical networks with real MEG data. We propose that hypergraphs yielded by bundling represent well the set of true cortical interactions that are detectable and dissociable in MEG/EEG connectivity analysis. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
IMS software developments for the detection of chemical warfare agent
NASA Technical Reports Server (NTRS)
Klepel, ST.; Graefenhain, U.; Lippe, R.; Stach, J.; Starrock, V.
1995-01-01
Interference compounds like gasoline, diesel, burning wood or fuel, etc. are presented in common battlefield situations. These compounds can cause detectors to respond as a false positive or interfere with the detector's ability to respond to target compounds such as chemical warfare agents. To ensure proper response of the ion mobility spectrometer to chemical warfare agents, two special software packages were developed and incorporated into the Bruker RAID-1. The programs suppress interferring signals caused by car exhaust or smoke gases resulting from burning materials and correct the influence of variable sample gas humidity which is important for detection and quantification of blister agents like mustard gas or lewisite.
Experimental investigation of false positive errors in auditory species occurrence surveys
Miller, David A.W.; Weir, Linda A.; McClintock, Brett T.; Grant, Evan H. Campbell; Bailey, Larissa L.; Simons, Theodore R.
2012-01-01
False positive errors are a significant component of many ecological data sets, which in combination with false negative errors, can lead to severe biases in conclusions about ecological systems. We present results of a field experiment where observers recorded observations for known combinations of electronically broadcast calling anurans under conditions mimicking field surveys to determine species occurrence. Our objectives were to characterize false positive error probabilities for auditory methods based on a large number of observers, to determine if targeted instruction could be used to reduce false positive error rates, and to establish useful predictors of among-observer and among-species differences in error rates. We recruited 31 observers, ranging in abilities from novice to expert, that recorded detections for 12 species during 180 calling trials (66,960 total observations). All observers made multiple false positive errors and on average 8.1% of recorded detections in the experiment were false positive errors. Additional instruction had only minor effects on error rates. After instruction, false positive error probabilities decreased by 16% for treatment individuals compared to controls with broad confidence interval overlap of 0 (95% CI: -46 to 30%). This coincided with an increase in false negative errors due to the treatment (26%; -3 to 61%). Differences among observers in false positive and in false negative error rates were best predicted by scores from an online test and a self-assessment of observer ability completed prior to the field experiment. In contrast, years of experience conducting call surveys was a weak predictor of error rates. False positive errors were also more common for species that were played more frequently, but were not related to the dominant spectral frequency of the call. Our results corroborate other work that demonstrates false positives are a significant component of species occurrence data collected by auditory methods. Instructing observers to only report detections they are completely certain are correct is not sufficient to eliminate errors. As a result, analytical methods that account for false positive errors will be needed, and independent testing of observer ability is a useful predictor for among-observer variation in observation error rates.
Characterisation of false-positive observations in botanical surveys
2017-01-01
Errors in botanical surveying are a common problem. The presence of a species is easily overlooked, leading to false-absences; while misidentifications and other mistakes lead to false-positive observations. While it is common knowledge that these errors occur, there are few data that can be used to quantify and describe these errors. Here we characterise false-positive errors for a controlled set of surveys conducted as part of a field identification test of botanical skill. Surveys were conducted at sites with a verified list of vascular plant species. The candidates were asked to list all the species they could identify in a defined botanically rich area. They were told beforehand that their final score would be the sum of the correct species they listed, but false-positive errors counted against their overall grade. The number of errors varied considerably between people, some people create a high proportion of false-positive errors, but these are scattered across all skill levels. Therefore, a person’s ability to correctly identify a large number of species is not a safeguard against the generation of false-positive errors. There was no phylogenetic pattern to falsely observed species; however, rare species are more likely to be false-positive as are species from species rich genera. Raising the threshold for the acceptance of an observation reduced false-positive observations dramatically, but at the expense of more false negative errors. False-positive errors are higher in field surveying of plants than many people may appreciate. Greater stringency is required before accepting species as present at a site, particularly for rare species. Combining multiple surveys resolves the problem, but requires a considerable increase in effort to achieve the same sensitivity as a single survey. Therefore, other methods should be used to raise the threshold for the acceptance of a species. For example, digital data input systems that can verify, feedback and inform the user are likely to reduce false-positive errors significantly. PMID:28533972
Kepler Certified False Positive Table
NASA Technical Reports Server (NTRS)
Bryson, Stephen T.; Batalha, Natalie Marie; Colon, Knicole Dawn; Coughlin, Jeffrey Langer; Haas, Michael R.; Henze, Chris; Huber, Daniel; Morton, Tim; Rowe, Jason Frank; Mullally, Susan Elizabeth;
2017-01-01
This document describes the Kepler Certied False Positive table hosted at the Exoplanet Archive1, herein referred to as the CFP table. This table is the result of detailed examination by the Kepler False Positive Working Group (FPWG) of declared false positives in the Kepler Object of Interest (KOI) tables (see, for example, Batalha et al. (2012); Burke et al.(2014); Rowe et al. (2015); Mullally et al. (2015); Coughlin et al. (2015b)) at the Exoplanet Archive. A KOI is considered a false positive if it is not due to a planet orbiting the KOI's target star. The CFP table contains all KOIs in the Exoplanet Archive cumulative KOI table. The purpose of the CFP table is to provide a list of certified false positive KOIs. A KOI is certified as a false positive when, in the judgement of the FPWG, there is no plausible planetary interpretation of the observational evidence, which we summarize by saying that the evidence for a false positive is compelling. This certification process involves detailed examination using all available data for each KOI, establishing a high-reliability ground truth set. The CFP table can be used to estimate the reliability of, for example, the KOI tables which are created using only Kepler photometric data, so the disposition of individual KOIs may differ in the KOI and CFP tables. Follow-up observers may find the CFP table useful to avoid observing false positives.
Singh, Deependra; Pitkäniemi, Janne; Malila, Nea; Anttila, Ahti
2016-09-01
Mammography has been found effective as the primary screening test for breast cancer. We estimated the cumulative probability of false positive screening test results with respect to symptom history reported at screen. A historical prospective cohort study was done using individual screening data from 413,611 women aged 50-69 years with 2,627,256 invitations for mammography screening between 1992 and 2012 in Finland. Symptoms (lump, retraction, and secretion) were reported at 56,805 visits, and 48,873 visits resulted in a false positive mammography result. Generalized linear models were used to estimate the probability of at least one false positive test and true positive at screening visits. The estimates were compared among women with and without symptoms history. The estimated cumulative probabilities were 18 and 6 % for false positive and true positive results, respectively. In women with a history of a lump, the cumulative probabilities of false positive test and true positive were 45 and 16 %, respectively, compared to 17 and 5 % with no reported lump. In women with a history of any given symptom, the cumulative probabilities of false positive test and true positive were 38 and 13 %, respectively. Likewise, women with a history of a 'lump and retraction' had the cumulative false positive probability of 56 %. The study showed higher cumulative risk of false positive tests and more cancers detected in women who reported symptoms compared to women who did not report symptoms at screen. The risk varies substantially, depending on symptom types and characteristics. Information on breast symptoms influences the balance of absolute benefits and harms of screening.
Detecting false positives in multielement designs: implications for brief assessments.
Bartlett, Sara M; Rapp, John T; Henrickson, Marissa L
2011-11-01
The authors assessed the extent to which multielement designs produced false positives using continuous duration recording (CDR) and interval recording with 10-s and 1-min interval sizes. Specifically, they created 6,000 graphs with multielement designs that varied in the number of data paths, and the number of data points per data path, using a random number generator. In Experiment 1, the authors visually analyzed the graphs for the occurrence of false positives. Results indicated that graphs depicting only two sessions for each condition (e.g., a control condition plotted with multiple test conditions) produced the highest percentage of false positives for CDR and interval recording with 10-s and 1-min intervals. Conversely, graphs with four or five sessions for each condition produced the lowest percentage of false positives for each method. In Experiment 2, they applied two new rules, which were intended to decrease false positives, to each graph that depicted a false positive in Experiment 1. Results showed that application of new rules decreased false positives to less than 5% for all of the graphs except for those with two data paths and two data points per data path. Implications for brief assessments are discussed.
Artes, Paul H; McLeod, David; Henson, David B
2002-01-01
To report on differences between the latency distributions of responses to stimuli and to false-positive catch trials in suprathreshold perimetry. To describe an algorithm for defining response time windows and to report on its performance in discriminating between true- and false-positive responses on the basis of response time (RT). A sample of 435 largely inexperienced patients underwent suprathreshold visual field examination on a perimeter that was modified to record RTs. Data were analyzed from 60,500 responses to suprathreshold stimuli and from 523 false-positive responses to catch trials. False-positive responses had much more variable latencies than responses to suprathreshold stimuli. An algorithm defining RT windows on the basis of z-transformed individual latency samples correctly identified more than 70% of false-positive responses to catch trials, whereas fewer than 3% of responses to suprathreshold stimuli were classified as false-positive responses. Latency analysis can be used to detect a substantial proportion of false-positive responses in suprathreshold perimetry. Rejection of such responses may increase the reliability of visual field screening by reducing variability and bias in a small but clinically important proportion of patients.
Basal forebrain amnesia: does the nucleus accumbens contribute to human memory?
Goldenberg, G.; Schuri, U.; Gromminger, O.; Arnold, U.
1999-01-01
OBJECTIVE—To analyse amnesia caused by basal forebrain lesions. METHODS—A single case study of a patient with amnesia after bleeding into the anterior portion of the left basal ganglia. Neuropsychological examination included tests of attention, executive function, working memory, recall, and recognition of verbal and non-verbal material, and recall from remote semantic and autobiographical memory. The patient's MRI and those of other published cases of basal forebrain amnesia were reviewed to specify which structures within the basal forebrain are crucial for amnesia. RESULTS—Attention and executive function were largely intact. There was anterograde amnesia for verbal material which affected free recall and recognition. With both modes of testing the patient produced many false positive responses and intrusions when lists of unrelated words had been memorised. However, he confabulated neither on story recall nor in day to day memory, nor in recall from remote memory. The lesion affected mainly the nucleus accumbens, but encroached on the inferior limb of the capsula interna and the most ventral portion of the nucleus caudatus and globus pallidus, and there was evidence of some atrophy of the head of the caudate nucleus. The lesion spared the nucleus basalis Meynert, the diagnonal band, and the septum, which are the sites of cholinergic cell concentrations. CONCLUSIONS—It seems unlikely that false positive responses were caused by insufficient strategic control of memory retrieval. This speaks against a major role of the capsular lesion which might disconnect the prefrontal cortex from the thalamus. It is proposed that the lesion of the nucleus accumbens caused amnesia. PMID:10406982
On the occurrence of false positives in tests of migration under an isolation with migration model
Hey, Jody; Chung, Yujin; Sethuraman, Arun
2015-01-01
The population genetic study of divergence is often done using a Bayesian genealogy sampler, like those implemented in IMa2 and related programs, and these analyses frequently include a likelihood-ratio test of the null hypothesis of no migration between populations. Cruickshank and Hahn (2014, Molecular Ecology, 23, 3133–3157) recently reported a high rate of false positive test results with IMa2 for data simulated with small numbers of loci under models with no migration and recent splitting times. We confirm these findings and discover that they are caused by a failure of the assumptions underlying likelihood ratio tests that arises when using marginal likelihoods for a subset of model parameters. We also show that for small data sets, with little divergence between samples from two populations, an excellent fit can often be found by a model with a low migration rate and recent splitting time and a model with a high migration rate and a deep splitting time. PMID:26456794
Automated detection of lung nodules with three-dimensional convolutional neural networks
NASA Astrophysics Data System (ADS)
Pérez, Gustavo; Arbeláez, Pablo
2017-11-01
Lung cancer is the cancer type with highest mortality rate worldwide. It has been shown that early detection with computer tomography (CT) scans can reduce deaths caused by this disease. Manual detection of cancer nodules is costly and time-consuming. We present a general framework for the detection of nodules in lung CT images. Our method consists of the pre-processing of a patient's CT with filtering and lung extraction from the entire volume using a previously calculated mask for each patient. From the extracted lungs, we perform a candidate generation stage using morphological operations, followed by the training of a three-dimensional convolutional neural network for feature representation and classification of extracted candidates for false positive reduction. We perform experiments on the publicly available LIDC-IDRI dataset. Our candidate extraction approach is effective to produce precise candidates with a recall of 99.6%. In addition, false positive reduction stage manages to successfully classify candidates and increases precision by a factor of 7.000.
Ibáñez-Sanz, Gemma; Garcia, Montse; Rodríguez-Moranta, Francisco; Binefa, Gemma; Gómez-Matas, Javier; Domènech, Xènia; Vidal, Carmen; Soriano, Antonio; Moreno, Víctor
2016-10-01
The most common side effect in population screening programmes is a false-positive result which leads to unnecessary risks and costs. To identify factors associated with false-positive results in a colorectal cancer screening programme with the faecal immunochemical test (FIT). Cross-sectional study of 472 participants with a positive FIT who underwent colonoscopy for confirmation of diagnosis between 2013 and 2014. A false-positive result was defined as having a positive FIT (≥20μg haemoglobin per gram of faeces) and follow-up colonoscopy without intermediate/high-risk lesions or cancer. Women showed a two-fold increased likelihood of a false-positive result compared with men (adjusted OR, 2.3; 95%CI, 1.5-3.4), but no female-specific factor was identified. The other variables associated with a false-positive result were successive screening (adjusted OR, 1.5; 95%CI, 1.0-2.2), anal disorders (adjusted OR, 3.1; 95%CI, 2.1-4.5) and the use of proton pump inhibitors (adjusted OR, 1.8; 95%CI, 1.1-2.9). Successive screening and proton pump inhibitor use were associated with FP in men. None of the other drugs were related to a false-positive FIT. Concurrent use of proton pump inhibitors at the time of FIT might increase the likelihood of a false-positive result. Further investigation is needed to determine whether discontinuing them could decrease the false-positive rate. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
False recollection of emotional pictures in Alzheimer's disease.
Gallo, David A; Foster, Katherine T; Wong, Jessica T; Bennett, David A
2010-10-01
Alzheimer's Disease (AD) can reduce the effects of emotional content on memory for studied pictures, but less is known about false memory. In healthy adults, emotionally arousing pictures can be more susceptible to false memory effects than neutral pictures, potentially because emotional pictures share conceptual similarities that cause memory confusions. We investigated these effects in AD patients and healthy controls. Participants studied pictures and their verbal labels, and then picture recollection was tested using verbal labels as retrieval cues. Some of the test labels had been associated with a picture at study, whereas other had not. On this picture recollection test, we found that both AD patients and controls incorrectly endorsed some of the test labels that had not been studied with pictures. These errors were associated with medium to high levels of confidence, indicating some degree of false recollection. Critically, these false recollection judgments were greater for emotional compared to neutral items, especially for positively valenced items, in both AD patients and controls. Dysfunction of the amygdala and hippocampus in early AD may impair recollection, but AD did not disrupt the effect of emotion on false recollection judgments. Copyright © 2010 Elsevier Ltd. All rights reserved.
Detection of immunocytological markers in photomicroscopic images
NASA Astrophysics Data System (ADS)
Friedrich, David; zur Jacobsmühlen, Joschka; Braunschweig, Till; Bell, André; Chaisaowong, Kraisorn; Knüchel-Clarke, Ruth; Aach, Til
2012-03-01
Early detection of cervical cancer can be achieved through visual analysis of cell anomalies. The established PAP smear achieves a sensitivity of 50-90%, most false negative results are caused by mistakes in the preparation of the specimen or reader variability in the subjective, visual investigation. Since cervical cancer is caused by human papillomavirus (HPV), the detection of HPV-infected cells opens new perspectives for screening of precancerous abnormalities. Immunocytochemical preparation marks HPV-positive cells in brush smears of the cervix with high sensitivity and specificity. The goal of this work is the automated detection of all marker-positive cells in microscopic images of a sample slide stained with an immunocytochemical marker. A color separation technique is used to estimate the concentrations of the immunocytochemical marker stain as well as of the counterstain used to color the nuclei. Segmentation methods based on Otsu's threshold selection method and Mean Shift are adapted to the task of segmenting marker-positive cells and their nuclei. The best detection performance of single marker-positive cells was achieved with the adapted thresholding method with a sensitivity of 95.9%. The contours differed by a modified Hausdorff Distance (MHD) of 2.8 μm. Nuclei of single marker positive cells were detected with a sensitivity of 95.9% and MHD = 1.02 μm.
False negative rates in Drosophila cell-based RNAi screens: a case study
2011-01-01
Background High-throughput screening using RNAi is a powerful gene discovery method but is often complicated by false positive and false negative results. Whereas false positive results associated with RNAi reagents has been a matter of extensive study, the issue of false negatives has received less attention. Results We performed a meta-analysis of several genome-wide, cell-based Drosophila RNAi screens, together with a more focused RNAi screen, and conclude that the rate of false negative results is at least 8%. Further, we demonstrate how knowledge of the cell transcriptome can be used to resolve ambiguous results and how the number of false negative results can be reduced by using multiple, independently-tested RNAi reagents per gene. Conclusions RNAi reagents that target the same gene do not always yield consistent results due to false positives and weak or ineffective reagents. False positive results can be partially minimized by filtering with transcriptome data. RNAi libraries with multiple reagents per gene also reduce false positive and false negative outcomes when inconsistent results are disambiguated carefully. PMID:21251254
[Roaming through methodology. XXXII. False test results].
van der Weijden, T; van den Akker, M
2001-05-12
The number of requests for diagnostic tests is rising. This leads to a higher chance of false test results. The false-negative proportion of a test is the proportion of negative test results among the diseased subjects. The false-positive proportion is the proportion of positive test results among the healthy subjects. The calculation of the false-positive proportion is often incorrect. For example, instead of 1 minus the specificity it is calculated as 1 minus the positive predictive value. This can lead to incorrect decision-making with respect to the application of the test. Physicians must apply diagnostic tests in such a way that the risk of false test results is minimal. The patient should be aware that a perfectly conclusive diagnostic test is rare in medical practice, and should more often be informed of the implications of false-positive and false-negative test results.
Wolf, Max; Kurvers, Ralf H J M; Ward, Ashley J W; Krause, Stefan; Krause, Jens
2013-04-07
In a wide range of contexts, including predator avoidance, medical decision-making and security screening, decision accuracy is fundamentally constrained by the trade-off between true and false positives. Increased true positives are possible only at the cost of increased false positives; conversely, decreased false positives are associated with decreased true positives. We use an integrated theoretical and experimental approach to show that a group of decision-makers can overcome this basic limitation. Using a mathematical model, we show that a simple quorum decision rule enables individuals in groups to simultaneously increase true positives and decrease false positives. The results from a predator-detection experiment that we performed with humans are in line with these predictions: (i) after observing the choices of the other group members, individuals both increase true positives and decrease false positives, (ii) this effect gets stronger as group size increases, (iii) individuals use a quorum threshold set between the average true- and false-positive rates of the other group members, and (iv) individuals adjust their quorum adaptively to the performance of the group. Our results have broad implications for our understanding of the ecology and evolution of group-living animals and lend themselves for applications in the human domain such as the design of improved screening methods in medical, forensic, security and business applications.
Wolf, Max; Kurvers, Ralf H. J. M.; Ward, Ashley J. W.; Krause, Stefan; Krause, Jens
2013-01-01
In a wide range of contexts, including predator avoidance, medical decision-making and security screening, decision accuracy is fundamentally constrained by the trade-off between true and false positives. Increased true positives are possible only at the cost of increased false positives; conversely, decreased false positives are associated with decreased true positives. We use an integrated theoretical and experimental approach to show that a group of decision-makers can overcome this basic limitation. Using a mathematical model, we show that a simple quorum decision rule enables individuals in groups to simultaneously increase true positives and decrease false positives. The results from a predator-detection experiment that we performed with humans are in line with these predictions: (i) after observing the choices of the other group members, individuals both increase true positives and decrease false positives, (ii) this effect gets stronger as group size increases, (iii) individuals use a quorum threshold set between the average true- and false-positive rates of the other group members, and (iv) individuals adjust their quorum adaptively to the performance of the group. Our results have broad implications for our understanding of the ecology and evolution of group-living animals and lend themselves for applications in the human domain such as the design of improved screening methods in medical, forensic, security and business applications. PMID:23407830
Causes of false-negative for high-grade urothelial carcinoma in urine cytology.
Lee, Paul J; Owens, Christopher L; Lithgow, Marie Y; Jiang, Zhong; Fischer, Andrew H
2016-12-01
The Paris System for classifying urine cytology emphasizes identification of high-grade urothelial carcinoma (HGUC). The causes of false-negative urine cytologies (UC) within this system are not well described. We identified 660 cases between 2005 and 2013 with both UC and subsequent cystoscopic biopsies. UC were classified as either Negative for HGUC or "Abnormal" ("Atypical", "Suspicious", and "Malignant"). Apparent false-negative cases were reviewed in a nonblinded fashion by two cytopathologists and two subspecialized genitourinary pathologists. A total of 199 of the 660 cases (30%) were histologically diagnosed as HGUC. The UC were "Abnormal" in 170/199 cases (sensitivity/specificity of 86%/71%). Twenty four apparent false negative cases were available for retrospective review. Five of 24 (21%) cystoscopic biopsies were found not to be HGUC on review (one false positive and four low-grade urothelial carcinoma (LGUC on review). Of the remaining 19 UC, 7 (29%) cytology samples were found to be truly negative on review, 11 (46%) were found to be Atypical, and 1 (4%) suspicious. Of the 12 UC that were at least "Atypical" with histologic HGUC on review: six misses (half) were attributed to obscuring inflammation/blood, four to poor preservation, eight to paucity of abnormal cells, and 1 case to interpretive error; many cases demonstrated overlapping reasons. About one fifth of apparent false negative diagnoses for HGUC can be because of overdiagnosis of HGUC by surgical pathologists. If poor preservation or obscured samples are called nondiagnostic, the sensitivity/specificity of UC for HGUC can be as high as 94%/71%. Diagn. Cytopathol. 2016;44:994-999. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Categorizing mistaken false positives in regulation of human and environmental health.
Hansen, Steffen Foss; Krayer von Krauss, Martin P; Tickner, Joel A
2007-02-01
One of the concerns often voiced by critics of the precautionary principle is that a widespread regulatory application of the principle will lead to a large number of false positives (i.e., over-regulation of minor risks and regulation of nonexisting risks). The present article proposes a general definition of a regulatory false positive, and seeks to identify case studies that can be considered authentic regulatory false positives. Through a comprehensive review of the science policy literature for proclaimed false positives and interviews with authorities on regulation and the precautionary principle we identified 88 cases. Following a detailed analysis of these cases, we found that few of the cases mentioned in the literature can be considered to be authentic false positives. As a result, we have developed a number of different categories for these cases of "mistaken false positives," including: real risks, "The jury is still out," nonregulated proclaimed risks, "Too narrow a definition of risk," and risk-risk tradeoffs. These categories are defined and examples are presented in order to illustrate their key characteristics. On the basis of our analysis, we were able to identify only four cases that could be defined as regulatory false positives in the light of today's knowledge and recognized uncertainty: the Southern Corn Leaf Blight, the Swine Flu, Saccharin, and Food Irradiation in relation to consumer health. We conclude that concerns about false positives do not represent a reasonable argument against future application of the precautionary principle.
Missing value imputation strategies for metabolomics data.
Armitage, Emily Grace; Godzien, Joanna; Alonso-Herranz, Vanesa; López-Gonzálvez, Ángeles; Barbas, Coral
2015-12-01
The origin of missing values can be caused by different reasons and depending on these origins missing values should be considered differently and dealt with in different ways. In this research, four methods of imputation have been compared with respect to revealing their effects on the normality and variance of data, on statistical significance and on the approximation of a suitable threshold to accept missing data as truly missing. Additionally, the effects of different strategies for controlling familywise error rate or false discovery and how they work with the different strategies for missing value imputation have been evaluated. Missing values were found to affect normality and variance of data and k-means nearest neighbour imputation was the best method tested for restoring this. Bonferroni correction was the best method for maximizing true positives and minimizing false positives and it was observed that as low as 40% missing data could be truly missing. The range between 40 and 70% missing values was defined as a "gray area" and therefore a strategy has been proposed that provides a balance between the optimal imputation strategy that was k-means nearest neighbor and the best approximation of positioning real zeros. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
An analysis of false positive reactions occurring with the Captia Syph G EIA.
Ross, J; Moyes, A; Young, H; McMillan, A
1991-01-01
AIM--The Captia Syph G enzyme immuno assay (EAI) offers the potential for the rapid automated detection of syphilis antibodies. This study was designed to assess the role of other sexually transmitted diseases (STDs) in producing false positive reactions in the Captia Syph G EIA. The role of rheumatoid factor (RF) as a potential source of false positives was also analysed. METHODS--Patients who attended a genitourinary medicine (GUM) department and gave a false positive reaction with the EIA between 1988 and 1990 were compared with women undergoing antenatal testing and with the control clinic population (EIA negative) over the same time period. The incidence of sexually transmitted disease (STD) in the clinic population and the false positive reactors was measured in relation to gonorrhoea, chlamydia, genital warts, candidiasis, "other conditions not requiring treatment" and "other conditions requiring treatment." Male: female sex ratios were also compared. Ninety two RF positive sera were analysed with the EIA. RESULTS--The rate of false positive reactions did not differ with respect to the diagnosis within the GUM clinic population. The antenatal group of women, however, had a lower incidence of false positive reactions than the GUM clinic group. No RF positive sera were positive on Captia Syph G EIA testing. CONCLUSIONS--There is no cross reaction between Captia Syph G EIA and any specific STD or with RF positive sera. The lower incidence of false positive reactions in antenatal women is unexplained but may be related to physiological changes associated with pregnancy. PMID:1743715
Automatic lumen segmentation in IVOCT images using binary morphological reconstruction
2013-01-01
Background Atherosclerosis causes millions of deaths, annually yielding billions in expenses round the world. Intravascular Optical Coherence Tomography (IVOCT) is a medical imaging modality, which displays high resolution images of coronary cross-section. Nonetheless, quantitative information can only be obtained with segmentation; consequently, more adequate diagnostics, therapies and interventions can be provided. Since it is a relatively new modality, many different segmentation methods, available in the literature for other modalities, could be successfully applied to IVOCT images, improving accuracies and uses. Method An automatic lumen segmentation approach, based on Wavelet Transform and Mathematical Morphology, is presented. The methodology is divided into three main parts. First, the preprocessing stage attenuates and enhances undesirable and important information, respectively. Second, in the feature extraction block, wavelet is associated with an adapted version of Otsu threshold; hence, tissue information is discriminated and binarized. Finally, binary morphological reconstruction improves the binary information and constructs the binary lumen object. Results The evaluation was carried out by segmenting 290 challenging images from human and pig coronaries, and rabbit iliac arteries; the outcomes were compared with the gold standards made by experts. The resultant accuracy was obtained: True Positive (%) = 99.29 ± 2.96, False Positive (%) = 3.69 ± 2.88, False Negative (%) = 0.71 ± 2.96, Max False Positive Distance (mm) = 0.1 ± 0.07, Max False Negative Distance (mm) = 0.06 ± 0.1. Conclusions In conclusion, by segmenting a number of IVOCT images with various features, the proposed technique showed to be robust and more accurate than published studies; in addition, the method is completely automatic, providing a new tool for IVOCT segmentation. PMID:23937790
Half, Elizabeth E; Mlynarsky, Liat; Naftali, Timna; Benjaminov, Fabiana; Konikoff, Fred M
2013-09-01
Fecal Occult Blood Test (FOBT) is an accepted screening test for colorectal cancer (CRC). It has been shown to decrease mortality by up to 30%. The outcome of screening failures has not been adequately studied. The purpose of this study was to assess the outcome of patients who were diagnosed with CRC after a false negative FOBT. We identified all consecutive CRCs from pathology reports between 2005 and 2010. Patients were divided according to their FOBT result. Those who became positive were compared to patients who remained negative. Altogether 401 CRCs were identified. Of those, 202 never performed a FOBT. At least one negative FOBT was performed by 133 individuals (67%). Of these, 76 remained negative (false negatives, FN) and 57 became positive (positive conversion, PC, controls). The prevalence of metastatic disease was threefold higher among the FNs as compared to the PC group (16 [22.2%] vs. 4 [7.5%], P=0.022). All-cause mortality was also significantly higher among FNs versus PCs (24 [31.6%] vs. 5 [8.8%], P=0.001); in Cox regression analysis of survival (covariates: FNs vs. PC, gender, age, medications and co-morbidities) FNs had increased mortality compared to the PC (HR 2.929, P=0.033, CI 95% 1.092-7.858). No statistically significant difference was found regarding all primary end points when comparing the FN and the "No test" group. These data disclose a particular risk of FOBT as a screening test. A subgroup of patients with "false" negative tests may have increased morbidity and mortality. Efforts should be made to recognize and characterize this high-risk group.
Identification of Low-Latency Obfuscated Traffic Using Multi-Attribute Analysis
2017-03-01
the distribution of common Tor packet sizes. Herrmann et al. also contend that the remaining variations in observed packet sizes are caused by OS...specific fragmentation and that Tor’s variation in packet size provides an additional level of protection as the false positive rate (FPR) using packet...three pre-filter variations , the observed FPR for non-Tor ranged from 94.4 percent to 7.2 percent, and the observed FNR for Tor ranged from 61.3
Comparison of multiple methods for the determination of sulphite in Allium and Brassica vegetables
Robbins Carlos, Katherine S.; de Jager, Lowri S.
2018-01-01
Sulphites are a family of additives regulated for use worldwide in food products. They must be declared on the label if they are present in concentrations greater than 10 mg kg−1, determined as sulphur dioxide (SO2). The current US regulatory method for sulphites, the optimised Monier–Williams method (OMW), produces false-positive results with vegetables from the Allium (garlic) and Brassica (cabbage) genera due to extraction conditions that are thought to cause endogenous sulphur compounds to release SO2. Recently, modifications to the OMW method (2× MW) were published that reportedly reduced this false-positive in garlic. However, no other vegetables from these genera have been investigated. In addition, an LC-MS/MS method was developed for sulphite analysis, but it has not yet been tested with these problematic matrices. Ten vegetable species were analysed using these sulphite methods (OMW titration, OMW gravimetric, 2× MW and LC-MS/MS) to determine the false-positive rate. Sulphite concentrations > 10 mg kg−1 SO2 were observed with the OMW analyses. The 2× MW method reduced the measured concentration in unsulphited samples to ≤ 10 mg kg−1 SO2 for all matrices analysed. The LC-MS/MS method showed concentrations < 10 mg kg−1 for the Brassica samples, but only displayed a slight reduction in the Allium matrices. Spiked recovery studies were conducted to determine if these methods can detect added sulphite. The 2× MW had recoveries of 17% and 42% for water and fresh garlic, respectively, and the LC-MS/MS had recoveries of 108%, 125%, 116% and 107% for water, fresh garlic, roasted garlic, and hummus, respectively. The low recoveries of the 2× MW may indicate that sulphur compounds cannot be properly quantified with this method. The ability to eliminate false-positives will enable accurate determination of added sulphite to ensure compliance with sulphite labelling requirements. PMID:27592824
Ndase, Patrick; Celum, Connie; Kidoguchi, Lara; Ronald, Allan; Fife, Kenneth H; Bukusi, Elizabeth; Donnell, Deborah; Baeten, Jared M
2015-01-01
Rapid HIV assays are the mainstay of HIV testing globally. Delivery of effective biomedical HIV prevention strategies such as antiretroviral pre-exposure prophylaxis (PrEP) requires periodic HIV testing. Because rapid tests have high (>95%) but imperfect specificity, they are expected to generate some false positive results. We assessed the frequency of true and false positive rapid results in the Partners PrEP Study, a randomized, placebo-controlled trial of PrEP. HIV testing was performed monthly using 2 rapid tests done in parallel with HIV enzyme immunoassay (EIA) confirmation following all positive rapid tests. A total of 99,009 monthly HIV tests were performed; 98,743 (99.7%) were dual-rapid HIV negative. Of the 266 visits with ≥1 positive rapid result, 99 (37.2%) had confirmatory positive EIA results (true positives), 155 (58.3%) had negative EIA results (false positives), and 12 (4.5%) had discordant EIA results. In the active PrEP arms, over two-thirds of visits with positive rapid test results were false positive results (69.2%, 110 of 159), although false positive results occurred at <1% (110/65,945) of total visits. When HIV prevalence or incidence is low due to effective HIV prevention interventions, rapid HIV tests result in a high number of false relative to true positive results, although the absolute number of false results will be low. Program roll-out for effective interventions should plan for quality assurance of HIV testing, mechanisms for confirmatory HIV testing, and counseling strategies for persons with positive rapid test results.
Experimental investigation of observation error in anuran call surveys
McClintock, B.T.; Bailey, L.L.; Pollock, K.H.; Simons, T.R.
2010-01-01
Occupancy models that account for imperfect detection are often used to monitor anuran and songbird species occurrence. However, presenceabsence data arising from auditory detections may be more prone to observation error (e.g., false-positive detections) than are sampling approaches utilizing physical captures or sightings of individuals. We conducted realistic, replicated field experiments using a remote broadcasting system to simulate simple anuran call surveys and to investigate potential factors affecting observation error in these studies. Distance, time, ambient noise, and observer abilities were the most important factors explaining false-negative detections. Distance and observer ability were the best overall predictors of false-positive errors, but ambient noise and competing species also affected error rates for some species. False-positive errors made up 5 of all positive detections, with individual observers exhibiting false-positive rates between 0.5 and 14. Previous research suggests false-positive errors of these magnitudes would induce substantial positive biases in standard estimators of species occurrence, and we recommend practices to mitigate for false positives when developing occupancy monitoring protocols that rely on auditory detections. These recommendations include additional observer training, limiting the number of target species, and establishing distance and ambient noise thresholds during surveys. ?? 2010 The Wildlife Society.
Kermani, Bahram G
2016-07-01
Crystal Genetics, Inc. is an early-stage genetic test company, focused on achieving the highest possible clinical-grade accuracy and comprehensiveness for detecting germline (e.g., in hereditary cancer) and somatic (e.g., in early cancer detection) mutations. Crystal's mission is to significantly improve the health status of the population, by providing high accuracy, comprehensive, flexible and affordable genetic tests, primarily in cancer. Crystal's philosophy is that when it comes to detecting mutations that are strongly correlated with life-threatening diseases, the detection accuracy of every single mutation counts: a single false-positive error could cause severe anxiety for the patient. And, more importantly, a single false-negative error could potentially cost the patient's life. Crystal's objective is to eliminate both of these error types.
Diagnostic accuracy of an ultrasonic multiple transducer cardiac imaging system
NASA Technical Reports Server (NTRS)
Popp, R. L.; Brown, O. R.; Harrison, D. C.
1975-01-01
An ultrasonic multiple-transducer imaging system for intracardiac structure visualization is developed in order to simplify visualization of the human heart in vivo without radiation hazard or invasion of the body. Results of the evaluation of the diagnostic accuracy of the devised system in a clinical setting for adult patients are presented and discussed. Criteria are presented for recognition of mitral valva prolapse, mitral stenosis, pericardial effusion, atrial septal defect, and left ventricular dyssynergy. The probable cause for false-positive and false-negative diagnoses is discussed. However, hypertrophic myopathy and congestive myopathy were unable to be detected. Since only qualitative criteria were used, it was not possible to differentiate patients with left ventricular volume overload from patients without cardiac pathology.
Eclipsing Binaries From the CSTAR Project at Dome A, Antarctica
NASA Astrophysics Data System (ADS)
Yang, Ming; Zhang, Hui; Wang, Songhu; Zhou, Ji-Lin; Zhou, Xu; Wang, Lingzhi; Wang, Lifan; Wittenmyer, R. A.; Liu, Hui-Gen; Meng, Zeyang; Ashley, M. C. B.; Storey, J. W. V.; Bayliss, D.; Tinney, Chris; Wang, Ying; Wu, Donghong; Liang, Ensi; Yu, Zhouyi; Fan, Zhou; Feng, Long-Long; Gong, Xuefei; Lawrence, J. S.; Liu, Qiang; Luong-Van, D. M.; Ma, Jun; Wu, Zhenyu; Yan, Jun; Yang, Huigen; Yang, Ji; Yuan, Xiangyan; Zhang, Tianmeng; Zhu, Zhenxi; Zou, Hu
2015-04-01
The Chinese Small Telescope ARray (CSTAR) has observed an area around the Celestial South Pole at Dome A since 2008. About 20,000 light curves in the i band were obtained during the observation season lasting from 2008 March to July. The photometric precision achieves about 4 mmag at i = 7.5 and 20 mmag at i = 12 within a 30 s exposure time. These light curves are analyzed using Lomb-Scargle, Phase Dispersion Minimization, and Box Least Squares methods to search for periodic signals. False positives may appear as a variable signature caused by contaminating stars and the observation mode of CSTAR. Therefore, the period and position of each variable candidate are checked to eliminate false positives. Eclipsing binaries are removed by visual inspection, frequency spectrum analysis, and a locally linear embedding technique. We identify 53 eclipsing binaries in the field of view of CSTAR, containing 24 detached binaries, 8 semi-detached binaries, 18 contact binaries, and 3 ellipsoidal variables. To derive the parameters of these binaries, we use the Eclipsing Binaries via Artificial Intelligence method. The primary and secondary eclipse timing variations (ETVs) for semi-detached and contact systems are analyzed. Correlated primary and secondary ETVs confirmed by false alarm tests may indicate an unseen perturbing companion. Through ETV analysis, we identify two triple systems (CSTAR J084612.64-883342.9 and CSTAR J220502.55-895206.7). The orbital parameters of the third body in CSTAR J220502.55-895206.7 are derived using a simple dynamical model.
Jaroenlak, Pattana; Sanguanrut, Piyachat; Williams, Bryony A. P.; Stentiford, Grant D.; Flegel, Timothy W.; Sritunyalucksana, Kallaya
2016-01-01
Hepatopancreatic microsporidiosis (HPM) caused by Enterocytozoon hepatopenaei (EHP) is an important disease of cultivated shrimp. Heavy infections may lead to retarded growth and unprofitable harvests. Existing PCR detection methods target the EHP small subunit ribosomal RNA (SSU rRNA) gene (SSU-PCR). However, we discovered that they can give false positive test results due to cross reactivity of the SSU-PCR primers with DNA from closely related microsporidia that infect other aquatic organisms. This is problematic for investigating and monitoring EHP infection pathways. To overcome this problem, a sensitive and specific nested PCR method was developed for detection of the spore wall protein (SWP) gene of EHP (SWP-PCR). The new SWP-PCR method did not produce false positive results from closely related microsporidia. The first PCR step of the SWP-PCR method was 100 times (104 plasmid copies per reaction vial) more sensitive than that of the existing SSU-PCR method (106 copies) but sensitivity was equal for both in the nested step (10 copies). Since the hepatopancreas of cultivated shrimp is not currently known to be infected with microsporidia other than EHP, the SSU-PCR methods are still valid for analyzing hepatopancreatic samples despite the lower sensitivity than the SWP-PCR method. However, due to its greater specificity and sensitivity, we recommend that the SWP-PCR method be used to screen for EHP in feces, feed and environmental samples for potential EHP carriers. PMID:27832178
Jaroenlak, Pattana; Sanguanrut, Piyachat; Williams, Bryony A P; Stentiford, Grant D; Flegel, Timothy W; Sritunyalucksana, Kallaya; Itsathitphaisarn, Ornchuma
2016-01-01
Hepatopancreatic microsporidiosis (HPM) caused by Enterocytozoon hepatopenaei (EHP) is an important disease of cultivated shrimp. Heavy infections may lead to retarded growth and unprofitable harvests. Existing PCR detection methods target the EHP small subunit ribosomal RNA (SSU rRNA) gene (SSU-PCR). However, we discovered that they can give false positive test results due to cross reactivity of the SSU-PCR primers with DNA from closely related microsporidia that infect other aquatic organisms. This is problematic for investigating and monitoring EHP infection pathways. To overcome this problem, a sensitive and specific nested PCR method was developed for detection of the spore wall protein (SWP) gene of EHP (SWP-PCR). The new SWP-PCR method did not produce false positive results from closely related microsporidia. The first PCR step of the SWP-PCR method was 100 times (104 plasmid copies per reaction vial) more sensitive than that of the existing SSU-PCR method (106 copies) but sensitivity was equal for both in the nested step (10 copies). Since the hepatopancreas of cultivated shrimp is not currently known to be infected with microsporidia other than EHP, the SSU-PCR methods are still valid for analyzing hepatopancreatic samples despite the lower sensitivity than the SWP-PCR method. However, due to its greater specificity and sensitivity, we recommend that the SWP-PCR method be used to screen for EHP in feces, feed and environmental samples for potential EHP carriers.
Browning, Brian L.; Yu, Zhaoxia
2009-01-01
We present a novel method for simultaneous genotype calling and haplotype-phase inference. Our method employs the computationally efficient BEAGLE haplotype-frequency model, which can be applied to large-scale studies with millions of markers and thousands of samples. We compare genotype calls made with our method to genotype calls made with the BIRDSEED, CHIAMO, GenCall, and ILLUMINUS genotype-calling methods, using genotype data from the Illumina 550K and Affymetrix 500K arrays. We show that our method has higher genotype-call accuracy and yields fewer uncalled genotypes than competing methods. We perform single-marker analysis of data from the Wellcome Trust Case Control Consortium bipolar disorder and type 2 diabetes studies. For bipolar disorder, the genotype calls in the original study yield 25 markers with apparent false-positive association with bipolar disorder at a p < 10−7 significance level, whereas genotype calls made with our method yield no associated markers at this significance threshold. Conversely, for markers with replicated association with type 2 diabetes, there is good concordance between genotype calls used in the original study and calls made by our method. Results from single-marker and haplotypic analysis of our method's genotype calls for the bipolar disorder study indicate that our method is highly effective at eliminating genotyping artifacts that cause false-positive associations in genome-wide association studies. Our new genotype-calling methods are implemented in the BEAGLE and BEAGLECALL software packages. PMID:19931040
Porter, Stephen; Taylor, Kristian; Ten Brinke, Leanne
2008-01-01
Despite a large body of false memory research, little has addressed the potential influence of an event's emotional content on susceptibility to false recollections. The Paradoxical Negative Emotion (PNE) hypothesis predicts that negative emotion generally facilitates memory but also heightens susceptibility to false memories. Participants were asked whether they could recall 20 "widely publicised" public events (half fictitious) ranging in emotional valence, with or without visual cues. Participants recalled a greater number of true negative events (M=3.31/5) than true positive (M=2.61/5) events. Nearly everyone (95%) came to recall at least one false event (M=2.15 false events recalled). Further, more than twice as many participants recalled any false negative (90%) compared to false positive (41.7%) events. Negative events, in general, were associated with more detailed memories and false negative event memories were more detailed than false positive event memories. Higher dissociation scores were associated with false recollections of negative events, specifically.
Li, Zhixi; He, Yifan; Keel, Stuart; Meng, Wei; Chang, Robert T; He, Mingguang
2018-03-02
To assess the performance of a deep learning algorithm for detecting referable glaucomatous optic neuropathy (GON) based on color fundus photographs. A deep learning system for the classification of GON was developed for automated classification of GON on color fundus photographs. We retrospectively included 48 116 fundus photographs for the development and validation of a deep learning algorithm. This study recruited 21 trained ophthalmologists to classify the photographs. Referable GON was defined as vertical cup-to-disc ratio of 0.7 or more and other typical changes of GON. The reference standard was made until 3 graders achieved agreement. A separate validation dataset of 8000 fully gradable fundus photographs was used to assess the performance of this algorithm. The area under receiver operator characteristic curve (AUC) with sensitivity and specificity was applied to evaluate the efficacy of the deep learning algorithm detecting referable GON. In the validation dataset, this deep learning system achieved an AUC of 0.986 with sensitivity of 95.6% and specificity of 92.0%. The most common reasons for false-negative grading (n = 87) were GON with coexisting eye conditions (n = 44 [50.6%]), including pathologic or high myopia (n = 37 [42.6%]), diabetic retinopathy (n = 4 [4.6%]), and age-related macular degeneration (n = 3 [3.4%]). The leading reason for false-positive results (n = 480) was having other eye conditions (n = 458 [95.4%]), mainly including physiologic cupping (n = 267 [55.6%]). Misclassification as false-positive results amidst a normal-appearing fundus occurred in only 22 eyes (4.6%). A deep learning system can detect referable GON with high sensitivity and specificity. Coexistence of high or pathologic myopia is the most common cause resulting in false-negative results. Physiologic cupping and pathologic myopia were the most common reasons for false-positive results. Copyright © 2018 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Hocagil, Hilal; Hocagil, Abdullah Cüneyt; Karacabey, Sinan; Akkaya, Tuğba; Şimşek, Gözde; Sanrı, Erkman
2015-09-01
This study aimed to discuss the effectiveness of Pneumoscan working with micropower impulse radar (MIR) technology in diagnosing pneumothorax (PTX) in the emergency department. Patients with suspicion of PTX and indication for thorax tomography (CT) were included into the study. Findings of the Thorax CT were compared with the results of Pneumoscan. Chi-square and Fisher's exact tests were used in categorical variables. One hundred and fifteen patients were included into the study group; twelve patients presented with PTX diagnosed by CT, 10 of which were detected by Pneumoscan. Thirty-six true negative results, sixty-seven false positive results, and two false negative results were obtained, which resulted in an overall sensitivity of 83.3%, specificity of 35.0% for Pneumoscan. There was no statistically significant difference between the effectiveness of Pneumoscan and CT on the detection of PTX (p=0.33). There was no difference between the size of PTX diagnosed by CT and PTX diagnosed by Pneumoscan (p=0.47). There was no statistically significant difference between Pneumoscan and CT on detecting the localisation of the PTX (p=1.00). For the 10 cases diagnosed by Pneumoscan, mean chest wall thickness was determined as 50.3 mm while mean chest wall thickness for two false negatives diagnosed by Pneumoscan was 56.5 mm. However, no statistically significant difference was found between the chest wall thickness and the effectiveness of Pneumoscan on the detection of the PTX (p=0.77). Among sixty-seven false positives diagnosed by Pneumoscan, 46.3% had additional medical signs such as bronchiectasis, pulmonary consolidation, pulmonary edema or pulmonary tumor when they had a reading with CT. The relationship between having additional medical signs at the reading with CT and the effectiveness of Pneumoscan on the detection of the PTX was investigated and no significant difference was found (p=0.472). Using Pneumoscan to detect PTX is controversial since the device has a high false positive ratio. Wherein, false positive diagnosis can cause unjustifiable chest tube insertion. In addition, the device failed to show the size of the PTX, and therefore, it did not aid in determining the treatment and prognosis on contrary to traditional diagnostic methods. The findings could not demonstrate that the device was efficient in emergency care. Further studies and increasing experience may change this outcome in upcoming years.
Generalized site occupancy models allowing for false positive and false negative errors
Royle, J. Andrew; Link, W.A.
2006-01-01
Site occupancy models have been developed that allow for imperfect species detection or ?false negative? observations. Such models have become widely adopted in surveys of many taxa. The most fundamental assumption underlying these models is that ?false positive? errors are not possible. That is, one cannot detect a species where it does not occur. However, such errors are possible in many sampling situations for a number of reasons, and even low false positive error rates can induce extreme bias in estimates of site occupancy when they are not accounted for. In this paper, we develop a model for site occupancy that allows for both false negative and false positive error rates. This model can be represented as a two-component finite mixture model and can be easily fitted using freely available software. We provide an analysis of avian survey data using the proposed model and present results of a brief simulation study evaluating the performance of the maximum-likelihood estimator and the naive estimator in the presence of false positive errors.
Muthukumar, Alagarraju; Alatoom, Adnan; Burns, Susan; Ashmore, Jerry; Kim, Anne; Emerson, Brian; Bannister, Edward; Ansari, M Qasim
2015-01-01
To assess the false-positive and false-negative rates of a 4th-generation human immunodeficiency virus (HIV) assay, the Abbott ARCHITECT, vs 2 HIV 3rd-generation assays, the Siemens Centaur and the Ortho-Clinical Diagnostics Vitros. We examined 123 patient specimens. In the first phase of the study, we compared 99 specimens that had a positive screening result via the 3rd-generation Vitros assay (10 positive, 82 negative, and 7 indeterminate via confirmatory immunofluorescent assay [IFA]/Western blot [WB] testing). In the second phase, we assessed 24 HIV-1 RNA-positive (positive result via the nuclear acid amplification test [NAAT] and negative/indeterminate results via the WB test) specimens harboring acute HIV infection. The 4th-generation ARCHITECT assay yielded fewer false-positive results (n = 2) than the 3rd-generation Centaur (n = 9; P = .02) and Vitros (n = 82; P <.001) assays. One confirmed positive case had a false-negative result via the Centaur assay. When specimens from the 24 patients with acute HIV-1 infection were tested, the ARCHITECT assay yielded fewer false-negative results (n = 5) than the Centaur (n = 10) (P = .13) and the other 3rd-generation tests (n = 16) (P = .002). This study indicates that the 4th-generation ARCHITECT HIV assay yields fewer false-positive and false-negative results than the 3rd-generation HIV assays we tested. Copyright© by the American Society for Clinical Pathology (ASCP).
Hundhausen, T; Müller, T H
2005-08-01
The microbial detection system BacT/ALERT (bioMérieux) is widely used to monitor bacterial contamination of platelet concentrates (PCs). Recently, the manufacturer introduced polycarbonate culture bottles and a modified pH-sensitive liquid emulsion sensor as microbial growth indicator. This reconfigured assay was investigated in a routine setting. In each of eight transfusion centers, samples from 500 consecutive PCs were monitored for 1 week. For all PCs with a positive BacT/ALERT signal, retained samples and, if available, original PC containers and concomitant red blood cell concentrates were analyzed independently. Initially BacT/ALERT-positive PCs without bacterial identification in any sample were defined as false-positive. BacT/ALERT-positive PCs with bacteria in the first sample only were called potentially positive. PCs with bacteria in the first sample and the same strain in at least one additional sample were accepted as positive. Five PCs (0.13%) were positive, 9 PCs (0.23%) were potentially positive, and 35 PCs (0.9%) were false-positive. The rate of false-positive BacT/ALERT results varied substantially between centers (<0.2%-3.2%). Tracings from false-positive cultures lacked an exponential increase of the signal during incubation. Most of these false-positives were due to malfunctioning cells in various BacT/ALERT incubation units. Careful assessment of individual tracings of samples with positive signals helps to identify malfunctioning incubation units. Their early shutdown or replacement minimizes the high rate of unrectifiable product rejects attributed to false-positive alarms and avoids unnecessary concern of doctors and patients after conversion to a reconfigured BacT/ALERT assay.
Reflectance-based skin detection in the short wave infrared band and its application to video
NASA Astrophysics Data System (ADS)
Langston, Tye
2016-10-01
Robust reflectance-based skin detection is a potentially powerful tool for security and search and rescue applications, especially when applied to video. However, to be useful it must be able to account for the variations of human skin, as well as other items in the environment that could cause false detections. This effort focused on identifying a robust skin detection scheme that is appropriate for video application. Skin reflectance was modeled to identify unique skin features and compare them to potential false positive materials. Based on these comparisons, specific wavelength bands were selected and different combinations of two and three optical filters were used for actively identifying skin, as well as identifying and removing potential false positive materials. One wavelength combination (1072
HangOut: generating clean PSI-BLAST profiles for domains with long insertions.
Kim, Bong-Hyun; Cong, Qian; Grishin, Nick V
2010-06-15
Profile-based similarity search is an essential step in structure-function studies of proteins. However, inclusion of non-homologous sequence segments into a profile causes its corruption and results in false positives. Profile corruption is common in multidomain proteins, and single domains with long insertions are a significant source of errors. We developed a procedure (HangOut) that, for a single domain with specified insertion position, cleans erroneously extended PSI-BLAST alignments to generate better profiles. HangOut is implemented in Python 2.3 and runs on all Unix-compatible platforms. The source code is available under the GNU GPL license at http://prodata.swmed.edu/HangOut/. Supplementary data are available at Bioinformatics online.
FDG-PET/CT can rule out malignancy in patients with vocal cord palsy.
Thomassen, Anders; Nielsen, Anne Lerberg; Lauridsen, Jeppe Kiilerich; Blomberg, Björn Alexander; Hess, Søren; Petersen, Henrik; Johansen, Allan; Asmussen, Jon Thor; Sørensen, Jesper Roed; Johansen, Jørgen; Godballe, Christian; Høilund-Carlsen, Poul Flemming
2014-01-01
The aim was to investigate the performance of (18)F-fluorodeoxyglucose PET/CT to rule out malignancy in patients with confirmed vocal cord palsy (VCP). Between January 2011 and June 2013, we retrospectively included consecutive patients referred to PET/CT with paresis or paralysis of one or both vocal cords. PET/CT results were compared to clinical workup and histopathology. The study comprised 65 patients (32 females) with a mean age of 66±12 years (range 37-89). Eleven patients (17%) had antecedent cancer. Twenty-seven (42%) were diagnosed with cancer during follow-up. The palsy was right-sided in 24 patients, left-sided in 37, and bilateral in 4. Median follow-up was 7 months (interquartile range 4-11 months). Patients without cancer were followed for at least three months. PET/CT suggested a malignancy in 35 patients (27 true positives, 8 false positives) and showed none in 30 (30 true negatives, 0 false negatives). Thus, the sensitivity, specificity, positive and negative predictive values, and accuracy were (95% confidence intervals in parenthesis): 100% (88%-100%), 79% (64%-89%), 77% (61%-88%), 100% (89%-100%), and 88% (78%-94%), respectively. Sixteen patients had palliative treatment, while 11 were treated with curative intent, emphasising the severity of VCP and the need for a rapid and accurate diagnostic work-up. In this retrospective survey, biopsy proven malignancy (whether newly diagnosed or relapsed) was the cause of VCP in almost half of patients (42%). PET/CT had a high sensitivity (100%) with a relatively high false positive rate, but was excellent in ruling out malignancy (negative predictive value 100%).
Is there a positive bias in false recognition? Evidence from confabulating amnesia patients.
Alkathiri, Nura H; Morris, Robin G; Kopelman, Michael D
2015-10-01
Although there is some evidence for a positive emotional bias in the content of confabulations in brain damaged patients, findings have been inconsistent. The present study used the semantic-associates procedure to induce false recall and false recognition in order to examine whether a positive bias would be found in confabulating amnesic patients, relative to non-confabulating amnesic patients and healthy controls. Lists of positive, negative and neutral words were presented in order to induce false recall or false recognition of non-presented (but semantically associated) words. The latter were termed 'critical intrusions'. Thirteen confabulating amnesic patients, 13 non-confabulating amnesic patients and 13 healthy controls were investigated. Confabulating patients falsely recognised a higher proportion of positive (but unrelated) words, compared with non-confabulating patients and healthy controls. No differences were found for recall memory. Signal detection analysis, however, indicated that the positive bias for false recognition memory might reflect weaker memory in the confabulating amnesic group. This suggested that amnesia patients with weaker memory are more likely to confabulate and the content of these confabulations are more likely to be positive. Copyright © 2015 Elsevier Ltd. All rights reserved.
Study of false positives in 5-ALA induced photodynamic diagnosis of bladder carcinoma
NASA Astrophysics Data System (ADS)
Draga, Ronald O. P.; Grimbergen, Matthijs C. M.; Kok, Esther T.; Jonges, Trudy G. N.; Bosch, J. L. H. R.
2009-02-01
Photodynamic diagnosis (PDD) is a technique that enhances the detection of tumors during cystoscopy using a photosensitizer which accumulates primarily in cancerous cells and will fluoresce when illuminated by violetblue light. A disadvantage of PDD is the relatively low specificity. In this retrospective study we aimed to identify predictors for false positive findings in PDD. Factors such as gender, age, recent transurethral resection of bladder tumors (TURBT), previous intravesical therapy (IVT) and urinary tract infections (UTIs) were examined for association with the false positive rates in a multivariate analysis. Data of 366 procedures and 200 patients were collected. Patients were instilled with 5-aminolevulinic acid (5-ALA) intravesically and 1253 biopsies were taken from tumors and suspicious lesions. Female gender and TURBT are independent predictors of false positives in PDD. However, previous intravesical therapy with Bacille Calmette-Guérin is also an important predictor of false positives. The false positive rate decreases during the first 9-12 weeks after the latest TURBT and the latest intravesical chemotherapy. Although shortly after IVT and TURBT false positives increase, PDD improves the diagnostic sensitivity and results in more adequate treatment strategies in a significant number of patients.
Wallis, Ilka; Pichler, Thomas
2018-08-01
Groundwater monitoring relies on the acquisition of 'representative' groundwater samples, which should reflect the ambient water quality at a given location. However, drilling of a monitoring well for sample acquisition has the potential to perturb groundwater conditions to a point that may prove to be detrimental to the monitoring objective. Following installation of 20 monitoring wells in close geographic proximity in central Florida, opposing concentration trends for As and Mo were observed. In the first year after well installation As and Mo concentrations increased in some wells by a factor of 2, while in others As and Mo concentrations decreased by a factor of up to 100. Given this relatively short period of time, a natural change in groundwater composition of such magnitude is not expected, leaving well installation itself as the likely cause for the observed concentration changes. Hence, initial concentrations were identified as 'false negatives' if concentrations increased with time or as 'false positives' if concentrations decreased. False negatives were observed if concentrations were already high, i.e., the As or Mo were present at the time of drilling. False positives were observed if concentrations were relatively lower, i.e., As or Mo were present at low concentrations of approximately 1 to 2μg/L before drilling, but then released from the aquifer matrix as a result of drilling. Generally, As and Mo were present in the aquifer matrix in either pyrite or organic matter, both of which are susceptible to dissolution if redox conditions change due to the addition of oxygen. Thus, introduction of an oxidant into an anoxic aquifer through use of an oxygen saturated drilling fluid served as the conceptual model for the trends where concentrations decreased with time. Mixing between drilling fluid and groundwater (i.e., dilution) was used as the conceptual model for scenarios where increasing trends were observed. Conceptual models were successfully tested through formulation and application of data-driven reactive transport models, using the USGS code MODFLOW in conjunction with the reactive multicomponent transport code PHT3D. Copyright © 2018 Elsevier B.V. All rights reserved.
Indicator saturation: a novel approach to detect multiple breaks in geodetic time series.
NASA Astrophysics Data System (ADS)
Jackson, L. P.; Pretis, F.; Williams, S. D. P.
2016-12-01
Geodetic time series can record long term trends, quasi-periodic signals at a variety of time scales from days to decades, and sudden breaks due to natural or anthropogenic causes. The causes of breaks range from instrument replacement to earthquakes to unknown (i.e. no attributable cause). Furthermore, breaks can be permanent or short-lived and range at least two orders of magnitude in size (mm to 100's mm). To account for this range of possible signal-characteristics requires a flexible time series method that can distinguish between true and false breaks, outliers and time-varying trends. One such method, Indicator Saturation (IS) comes from the field of econometrics where analysing stochastic signals in these terms is a common problem. The IS approach differs from alternative break detection methods by considering every point in the time series as a break until it is demonstrated statistically that it is not. A linear model is constructed with a break function at every point in time, and all but statistically significant breaks are removed through a general-to-specific model selection algorithm for more variables than observations. The IS method is flexible because it allows multiple breaks of different forms (e.g. impulses, shifts in the mean, and changing trends) to be detected, while simultaneously modelling any underlying variation driven by additional covariates. We apply the IS method to identify breaks in a suite of synthetic GPS time series used for the Detection of Offsets in GPS Experiments (DOGEX). We optimise the method to maximise the ratio of true-positive to false-positive detections, which improves estimates of errors in the long term rates of land motion currently required by the GPS community.
Karaceper, Maria D; Chakraborty, Pranesh; Coyle, Doug; Wilson, Kumanan; Kronick, Jonathan B; Hawken, Steven; Davies, Christine; Brownell, Marni; Dodds, Linda; Feigenbaum, Annette; Fell, Deshayne B; Grosse, Scott D; Guttmann, Astrid; Laberge, Anne-Marie; Mhanni, Aizeddin; Miller, Fiona A; Mitchell, John J; Nakhla, Meranda; Prasad, Chitra; Rockman-Greenberg, Cheryl; Sparkes, Rebecca; Wilson, Brenda J; Potter, Beth K
2016-02-03
There is no consensus in the literature regarding the impact of false positive newborn screening results on early health care utilization patterns. We evaluated the impact of false positive newborn screening results for medium-chain acyl-CoA dehydrogenase deficiency (MCADD) in a cohort of Ontario infants. The cohort included all children who received newborn screening in Ontario between April 1, 2006 and March 31, 2010. Newborn screening and diagnostic confirmation results were linked to province-wide health care administrative datasets covering physician visits, emergency department visits, and inpatient hospitalizations, to determine health service utilization from April 1, 2006 through March 31, 2012. Incidence rate ratios (IRRs) were used to compare those with false positive results for MCADD to those with negative newborn screening results, stratified by age at service use. We identified 43 infants with a false positive newborn screening result for MCADD during the study period. These infants experienced significantly higher rates of physician visits (IRR: 1.42) and hospitalizations (IRR: 2.32) in the first year of life relative to a screen negative cohort in adjusted analyses. Differences in health services use were not observed after the first year of life. The higher use of some health services among false positive infants during the first year of life may be explained by a psychosocial impact of false positive results on parental perceptions of infant health, and/or by differences in underlying health status. Understanding the impact of false positive newborn screening results can help to inform newborn screening programs in designing support and education for families. This is particularly important as additional disorders are added to expanded screening panels, yielding important clinical benefits for affected children but also a higher frequency of false positive findings.
Automated segmentation of serous pigment epithelium detachment in SD-OCT images
NASA Astrophysics Data System (ADS)
Sun, Zhuli; Shi, Fei; Xiang, Dehui; Chen, Haoyu; Chen, Xinjian
2015-03-01
Pigment epithelium detachment (PED) is an important clinical manifestation of multiple chorio-retinal disease processes, which can cause the loss of central vision. A 3-D method is proposed to automatically segment serous PED in SD-OCT images. The proposed method consists of five steps: first, a curvature anisotropic diffusion filter is applied to remove speckle noise. Second, the graph search method is applied for abnormal retinal layer segmentation associated with retinal pigment epithelium (RPE) deformation. During this process, Bruch's membrane, which doesn't show in the SD-OCT images, is estimated with the convex hull algorithm. Third, the foreground and background seeds are automatically obtained from retinal layer segmentation result. Fourth, the serous PED is segmented based on the graph cut method. Finally, a post-processing step is applied to remove false positive regions based on mathematical morphology. The proposed method was tested on 20 SD-OCT volumes from 20 patients diagnosed with serous PED. The average true positive volume fraction (TPVF), false positive volume fraction (FPVF), dice similarity coefficient (DSC) and positive predictive value (PPV) are 97.19%, 0.03%, 96.34% and 95.59%, respectively. Linear regression analysis shows a strong correlation (r = 0.975) comparing the segmented PED volumes with the ground truth labeled by an ophthalmology expert. The proposed method can provide clinicians with accurate quantitative information, including shape, size and position of the PED regions, which can assist diagnose and treatment.
Accounting for false-positive acoustic detections of bats using occupancy models
Clement, Matthew J.; Rodhouse, Thomas J.; Ormsbee, Patricia C.; Szewczak, Joseph M.; Nichols, James D.
2014-01-01
4. Synthesis and applications. Our results suggest that false positives sufficient to affect inferences may be common in acoustic surveys for bats. We demonstrate an approach that can estimate occupancy, regardless of the false-positive rate, when acoustic surveys are paired with capture surveys. Applications of this approach include monitoring the spread of White-Nose Syndrome, estimating the impact of climate change and informing conservation listing decisions. We calculate a site-specific probability of occupancy, conditional on survey results, which could inform local permitting decisions, such as for wind energy projects. More generally, the magnitude of false positives suggests that false-positive occupancy models can improve accuracy in research and monitoring of bats and provide wildlife managers with more reliable information.
Analysis of false results in a series of 835 fine needle aspirates of breast lesions.
Willis, S L; Ramzy, I
1995-01-01
To analyze cases of false diagnoses from a large series to help increase the accuracy of fine needle aspiration of palpable breast lesions. The results of FNA of 835 palpable breast lesions were analyzed to determine the reasons for false positive, false negative and false suspicious diagnoses. Of the 835 aspirates, 174 were reported as positive, 549 as negative and 66 as suspicious or atypical but not diagnostic of malignancy. Forty-six cases were considered unsatisfactory. Tissue was available for comparison in 286 cases. The cytologic diagnoses in these cases were reported as follows: positive, 125 (43.7%); suspicious, 33 (11.5%); atypical, 18 (6.2%); negative, 92 (32%); and unsatisfactory, 18 (6.2%). There was one false positive diagnosis, yielding a false positive rate of 0.8%. This lesion was a case of fibrocystic change with hyperplasia, focal fat necrosis and reparative atypia. There were 14 false negative cases, resulting in a false negative rate of 13.2%. Nearly all these cases were sampling errors and included infiltrating ductal carcinomas (9), ductal carcinomas in situ (2), infiltrating lobular carcinomas (2) and tubular carcinoma (1). Most of the suspicious and atypical lesions proved to be carcinomas (35/50). The remainder were fibroadenomas (6), fibrocystic change (4), gynecomastia (2), adenosis (2) and granulomatous mastitis (1). A positive diagnosis of malignancy by FNA is reliable in establishing the diagnosis and planning the treatment of breast cancer. The false-positive rate is very low, with only a single case reported in 835 aspirates. Most false negatives are due to sampling and not to interpretive difficulties. The category "suspicious but not diagnostic of malignancy" serves a useful purpose in management of patients with breast lumps.
Ruiz-Gutierrez, Viviana; Hooten, Melvin B.; Campbell Grant, Evan H.
2016-01-01
Biological monitoring programmes are increasingly relying upon large volumes of citizen-science data to improve the scope and spatial coverage of information, challenging the scientific community to develop design and model-based approaches to improve inference.Recent statistical models in ecology have been developed to accommodate false-negative errors, although current work points to false-positive errors as equally important sources of bias. This is of particular concern for the success of any monitoring programme given that rates as small as 3% could lead to the overestimation of the occurrence of rare events by as much as 50%, and even small false-positive rates can severely bias estimates of occurrence dynamics.We present an integrated, computationally efficient Bayesian hierarchical model to correct for false-positive and false-negative errors in detection/non-detection data. Our model combines independent, auxiliary data sources with field observations to improve the estimation of false-positive rates, when a subset of field observations cannot be validated a posteriori or assumed as perfect. We evaluated the performance of the model across a range of occurrence rates, false-positive and false-negative errors, and quantity of auxiliary data.The model performed well under all simulated scenarios, and we were able to identify critical auxiliary data characteristics which resulted in improved inference. We applied our false-positive model to a large-scale, citizen-science monitoring programme for anurans in the north-eastern United States, using auxiliary data from an experiment designed to estimate false-positive error rates. Not correcting for false-positive rates resulted in biased estimates of occupancy in 4 of the 10 anuran species we analysed, leading to an overestimation of the average number of occupied survey routes by as much as 70%.The framework we present for data collection and analysis is able to efficiently provide reliable inference for occurrence patterns using data from a citizen-science monitoring programme. However, our approach is applicable to data generated by any type of research and monitoring programme, independent of skill level or scale, when effort is placed on obtaining auxiliary information on false-positive rates.
Hernández-Bou, S; Trenchs Sainz de la Maza, V; Esquivel Ojeda, J N; Gené Giralt, A; Luaces Cubells, C
2015-06-01
The aim of this study is to identify predictive factors of bacterial contamination in positive blood cultures (BC) collected in an emergency department. A prospective, observational and analytical study was conducted on febrile children aged on to 36 months, who had no risk factors of bacterial infection, and had a BC collected in the Emergency Department between November 2011 and October 2013 in which bacterial growth was detected. The potential BC contamination predicting factors analysed were: maximum temperature, time to positivity, initial Gram stain result, white blood cell count, absolute neutrophil count, band count, and C-reactive protein (CRP). Bacteria grew in 169 BC. Thirty (17.8%) were finally considered true positives and 139 (82.2%) false positives. All potential BC contamination predicting factors analysed, except maximum temperature, showed significant differences between true positives and false positives. CRP value, time to positivity, and initial Gram stain result are the best predictors of false positives in BC. The positive predictive values of a CRP value≤30mg/L, BC time to positivity≥16h, and initial Gram stain suggestive of a contaminant in predicting a FP, are 95.1, 96.9 and 97.5%, respectively. When all 3 conditions are applied, their positive predictive value is 100%. Four (8.3%) patients with a false positive BC and discharged to home were revaluated in the Emergency Department. The majority of BC obtained in the Emergency Department that showed positive were finally considered false positives. Initial Gram stain, time to positivity, and CRP results are valuable diagnostic tests in distinguishing between true positives and false positives in BC. The early detection of false positives will allow minimising their negative consequences. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.
Slater, Robert A; Koren, Shlomit; Ramot, Yoram; Buchs, Andreas; Rapoport, Micha J
2014-01-01
The Semmes-Weinstein monofilament is the most widely used test to diagnose the loss of protective sensation. The commonly used protocol of the International Consensus on the Diabetic Foot includes a 'sham' application that allows for false-positive answers. We sought to study the heretofore unexamined significance of false-positive answers. Forty-five patients with diabetes and a history of pedal ulceration (Group I) and 81 patients with diabetes but no history of ulceration (Group II) were studied. The three original sites of the International Consensus on the Diabetic Foot at the hallux, 1st metatarsal and 5th metatarsal areas were used. At each location, the test was performed three times: 2 actual and 1 "sham" applications. Scores were graded from 0 to 3 based upon correct responses. Determination of loss of protective sensation was performed with and without calculating a false-positive answer as a minus 1 score. False-positive responses were found in a significant percentage of patients with and without history of ulceration. Introducing false-positive results as minus 1 into the test outcome significantly increased the number of patients diagnosed with loss of protective sensation in both groups. False-positive answers can significantly affect Semmes-Weinstein monofilament test results and the diagnosis of LOPS. A model that accounts for false-positive answers is offered. Copyright © 2013 John Wiley & Sons, Ltd.
Value of a Single-Tube Widal Test in Diagnosis of Typhoid Fever in Vietnam
Parry, Christopher M.; Hoa, Nguyen Thi Tuyet; Diep, To Song; Wain, John; Chinh, Nguyen Tran; Vinh, Ha; Hien, Tran Tinh; White, Nicholas J.; Farrar, Jeremy J.
1999-01-01
The diagnostic value of an acute-phase single-tube Widal test for suspected typhoid fever was evaluated with 2,000 Vietnamese patients admitted to an infectious disease referral hospital between 1993 and 1998. Test patients had suspected typhoid fever and a blood culture positive for Salmonella typhi (n= 1,400) or Salmonella paratyphi A (n = 45). Control patients had a febrile illness for which another cause was confirmed (malaria [n = 103], dengue [n = 76], or bacteremia due to another microorganism [n = 156] or tetanus (n = 265). An O-agglutinin titer of ≥100 was found in 18% of the febrile controls and 7% of the tetanus patients. Corresponding values for H agglutinins were 8 and 1%, respectively. The O-agglutinin titer was ≥100 in 83% of the blood culture-positive typhoid fever cases, and the H-agglutinin titer was ≥100 in 67%. The disease prevalence in investigated patients in this hospital was 30.8% (95% confidence interval, 26.8 to 35.1%); at this prevalence, an elevated level of H agglutinins gave better positive predictive values for typhoid fever than did O agglutinins. With a cutoff titer of ≥200 for O agglutinin or ≥100 for H agglutinin, the Widal test would diagnose correctly 74% of the blood culture-positive cases of typhoid fever. However, 14% of the positive results would be false-positive, and 10% of the negative results would be false-negative. The Widal test can be helpful in the laboratory diagnosis of typhoid fever in Vietnam if interpreted with care. PMID:10449469
Hwang, Kyu-Baek; Lee, In-Hee; Park, Jin-Ho; Hambuch, Tina; Choe, Yongjoon; Kim, MinHyeok; Lee, Kyungjoon; Song, Taemin; Neu, Matthew B; Gupta, Neha; Kohane, Isaac S; Green, Robert C; Kong, Sek Won
2014-08-01
As whole genome sequencing (WGS) uncovers variants associated with rare and common diseases, an immediate challenge is to minimize false-positive findings due to sequencing and variant calling errors. False positives can be reduced by combining results from orthogonal sequencing methods, but costly. Here, we present variant filtering approaches using logistic regression (LR) and ensemble genotyping to minimize false positives without sacrificing sensitivity. We evaluated the methods using paired WGS datasets of an extended family prepared using two sequencing platforms and a validated set of variants in NA12878. Using LR or ensemble genotyping based filtering, false-negative rates were significantly reduced by 1.1- to 17.8-fold at the same levels of false discovery rates (5.4% for heterozygous and 4.5% for homozygous single nucleotide variants (SNVs); 30.0% for heterozygous and 18.7% for homozygous insertions; 25.2% for heterozygous and 16.6% for homozygous deletions) compared to the filtering based on genotype quality scores. Moreover, ensemble genotyping excluded > 98% (105,080 of 107,167) of false positives while retaining > 95% (897 of 937) of true positives in de novo mutation (DNM) discovery in NA12878, and performed better than a consensus method using two sequencing platforms. Our proposed methods were effective in prioritizing phenotype-associated variants, and an ensemble genotyping would be essential to minimize false-positive DNM candidates. © 2014 WILEY PERIODICALS, INC.
Hwang, Kyu-Baek; Lee, In-Hee; Park, Jin-Ho; Hambuch, Tina; Choi, Yongjoon; Kim, MinHyeok; Lee, Kyungjoon; Song, Taemin; Neu, Matthew B.; Gupta, Neha; Kohane, Isaac S.; Green, Robert C.; Kong, Sek Won
2014-01-01
As whole genome sequencing (WGS) uncovers variants associated with rare and common diseases, an immediate challenge is to minimize false positive findings due to sequencing and variant calling errors. False positives can be reduced by combining results from orthogonal sequencing methods, but costly. Here we present variant filtering approaches using logistic regression (LR) and ensemble genotyping to minimize false positives without sacrificing sensitivity. We evaluated the methods using paired WGS datasets of an extended family prepared using two sequencing platforms and a validated set of variants in NA12878. Using LR or ensemble genotyping based filtering, false negative rates were significantly reduced by 1.1- to 17.8-fold at the same levels of false discovery rates (5.4% for heterozygous and 4.5% for homozygous SNVs; 30.0% for heterozygous and 18.7% for homozygous insertions; 25.2% for heterozygous and 16.6% for homozygous deletions) compared to the filtering based on genotype quality scores. Moreover, ensemble genotyping excluded > 98% (105,080 of 107,167) of false positives while retaining > 95% (897 of 937) of true positives in de novo mutation (DNM) discovery, and performed better than a consensus method using two sequencing platforms. Our proposed methods were effective in prioritizing phenotype-associated variants, and ensemble genotyping would be essential to minimize false positive DNM candidates. PMID:24829188
Flagging threshold optimization for manual blood smear review in primary care laboratory.
Bihl, Pierre-Adrien
2018-04-01
Manual blood smear review is required when an anomaly detected by the automated hematologic analyzer triggers a flag. Our will through this study is to optimize these flagging thresholds for manual slide review in order to limit workload, while insuring clinical care through no extra false-negative. Flagging causes of 4,373 samples were investigated by manual slide review, after having been run on ADVIA 2120i. A set of 6 user-adjustments is proposed. By implementing all recommendations that we made, false-positive rate falls from 81.8% to 58.6%, while PPV increases from 18.2% to 23.7%. Hence, use of such optimized thresholds enables us to maximize efficiency without altering clinical care, but each laboratory should establish its own criteria to take into consideration local distinctive features.
Accuracy in inference of nursing diagnoses in heart failure patients.
Pereira, Juliana de Melo Vellozo; Cavalcanti, Ana Carla Dantas; Lopes, Marcos Venícios de Oliveira; da Silva, Valéria Gonçalves; de Souza, Rosana Oliveira; Gonçalves, Ludmila Cuzatis
2015-01-01
Heart failure (HF) is a common cause of hospitalization and requires accuracy in clinical judgment and appropriate nursing diagnoses. to determine the accuracy of nursing diagnoses of fatigue, intolerance to activity and decreased cardiac output in hospitalized HF patients. descriptive study applied to nurses with experience in NANDA-I and/or HF nursing diagnoses. Evaluation and accuracy were determined by calculating efficacy (E), false negative (FN), false positive (FP) and trend (T) measures. Nurses who showed acceptable inspection for two diagnoses were selected. the nursing diagnosis of fatigue was the most commonly mistaken diagnosis identified by the nursing evaluators. the search for improving diagnostic accuracy reaffirms the need for continuous and specific training to improve the diagnosis capability of nurses. the training allowed the exercise of clinical judgment and better accuracy of nurses.
The problem of false positives and false negatives in violent video game experiments.
Ferguson, Christopher J
The problem of false positives and negatives has received considerable attention in behavioral research in recent years. The current paper uses video game violence research as an example of how such issues may develop in a field. Despite decades of research, evidence on whether violent video games (VVGs) contribute to aggression in players has remained mixed. Concerns have been raised in recent years that experiments regarding VVGs may suffer from both "false positives" and "false negatives." The current paper examines this issue in three sets of video game experiments, two sets of video game experiments on aggression and prosocial behaviors identified in meta-analysis, and a third group of recent null studies. Results indicated that studies of VVGs and aggression appear to be particularly prone to false positive results. Studies of VVGs and prosocial behavior, by contrast are heterogeneous and did not demonstrate any indication of false positive results. However, their heterogeneous nature made it difficult to base solid conclusions on them. By contrast, evidence for false negatives in null studies was limited, and little evidence emerged that null studies lacked power in comparison those highlighted in past meta-analyses as evidence for effects. These results are considered in light of issues related to false positives and negatives in behavioral science more broadly. Copyright © 2017 Elsevier Ltd. All rights reserved.
Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?
Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M. Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz
2015-01-01
Background Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Methodology/Principal Findings Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). Conclusion The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study. PMID:26161864
Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?
Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz
2015-01-01
Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.
Chacón, Lucía; Mateos, María Luisa; Holguín, África
2017-07-01
Despite the high specificity of fourth-generation enzyme immunoassays (4th-gen-EIA) for screening during HIV diagnosis, their positive predictive value is low in populations with low HIV prevalence. Thus, screening should be optimized to reduce false positive results. The influence of sample cutoff (S/CO) values by a 4th-gen-EIA with the false positive rate during the routine HIV diagnosis in a low HIV prevalence population was evaluated. A total of 30,201 sera were tested for HIV diagnosis using Abbott Architect ® HIV-Ag/Ab-Combo 4th-gen-EIA at a hospital in Spain during 17 months. Architect S/CO values were recorded, comparing the HIV-1 positive results following Architect interpretation (S/CO≥1) with the final HIV-1 diagnosis by confirmatory tests (line immunoassay, LIA and/or nucleic acid test, NAT). ROC curve was also performed. Among the 30,201 HIV performed tests, 256 (0.85%) were positive according to Architect interpretation (S/CO≥1) but only 229 (0.76%) were definitively HIV-1 positive after LIA and/or NAT. Thus, 27 (10.5%) of 256 samples with S/CO≥1 by Architect were false positive diagnose. The false positive rate decreased when the S/CO ratio increased. All 19 samples with S/CO ≤10 were false positives and all 220 with S/CO>50 true HIV-positives. The optimal S/CO cutoff value provided by ROC curves was 32.7. No false negative results were found. We show that very low S/CO values during HIV-1 screening using Architect can result HIV negative after confirmation by LIA and NAT. The false positive rate is reduced when S/CO increases. Copyright © 2017 Elsevier B.V. All rights reserved.
Bruijn, Merel M C; Hermans, Frederik J R; Vis, Jolande Y; Wilms, Femke F; Oudijk, Martijn A; Kwee, Anneke; Porath, Martina M; Oei, Guid; Scheepers, Hubertina C J; Spaanderman, Marc E A; Bloemenkamp, Kitty W M; Haak, Monique C; Bolte, Antoinette C; Vandenbussche, Frank P H A; Woiski, Mallory D; Bax, Caroline J; Cornette, Jérôme M J; Duvekot, Johannes J; Bijvank, Bas W A N I J; van Eyck, Jim; Franssen, Maureen T M; Sollie, Krystyna M; van der Post, Joris A M; Bossuyt, Patrick M M; Kok, Marjolein; Mol, Ben W J; van Baaren, Gert-Jan
2017-02-01
Objective We assessed the influence of external factors on false-positive, false-negative, and invalid fibronectin results in the prediction of spontaneous delivery within 7 days. Methods We studied symptomatic women between 24 and 34 weeks' gestational age. We performed uni- and multivariable logistic regression to estimate the effect of external factors (vaginal soap, digital examination, transvaginal sonography, sexual intercourse, vaginal bleeding) on the risk of false-positive, false-negative, and invalid results, using spontaneous delivery within 7 days as the outcome. Results Out of 708 women, 237 (33%) had a false-positive result; none of the factors showed a significant association. Vaginal bleeding increased the proportion of positive fetal fibronectin (fFN) results, but was significantly associated with a lower risk of false-positive test results (odds ratio [OR], 0.22; 95% confidence intervals [CI], 0.12-0.39). Ten women (1%) had a false-negative result. None of the investigated factors was significantly associated with a significantly higher risk of false-negative results. Twenty-one tests (3%) were invalid; only vaginal bleeding showed a significant association (OR, 4.5; 95% CI, 1.7-12). Conclusion The effect of external factors on the performance of qualitative fFN testing is limited, with vaginal bleeding as the only factor that reduces its validity. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Keller, Karsten; Stelzer, Kathrin; Munzel, Thomas; Ostad, Mir Abolfazl
2016-12-01
Exercise echocardiography is a reliable routine test in patients with known or suspected coronary artery disease. However, in ∼15% of all patients, stress echocardiography leads to false-positive stress echocardiography results. We aimed to investigate the impact of hypertension on stress echocardiographic results. We performed a retrospective study of patients with suspected or known stable coronary artery disease who underwent a bicycle exercise stress echocardiography. Patients with false-positive stress results were compared with those with appropriate results. 126 patients with suspected or known coronary artery disease were included in this retrospective study. 23 patients showed false-positive stress echocardiography results. Beside comparable age, gender distribution and coronary artery status, hypertension was more prevalent in patients with false-positive stress results (95.7% vs. 67.0%, p = 0.0410). Exercise peak load revealed a borderline-significance with lower loads in patients with false-positive results (100.0 (IQR 75.0/137.5) vs. 125.0 (100.0/150.0) W, p = 0.0601). Patients with false-positive stress results showed higher systolic (2.05 ± 0.69 vs. 1.67 ± 0.39 mmHg/W, p = 0.0193) and diastolic (1.03 ± 0.38 vs. 0.80 ± 0.28 mmHg/W, p = 0.0165) peak blood pressure (BP) per wattage. In a multivariate logistic regression test, hypertension (OR 17.6 [CI 95% 1.9-162.2], p = 0.0115), and systolic (OR 4.12 [1.56-10.89], p = 0.00430) and diastolic (OR 13.74 [2.46-76.83], p = 0.00285) peak BP per wattage, were associated with false-positive exercise results. ROC analysis for systolic and diastolic peak BP levels per wattage showed optimal cut-off values of 1.935mmHg/W and 0.823mmHg/W, indicating false-positive exercise echocardiographic results with AUCs of 0.660 and 0.664, respectively. Hypertension is a risk factor for false-positive stress exercise echocardiographic results in patients with known or suspected coronary artery disease. Presence of hypertension was associated with 17.6-fold elevated risk of false-positive results.
Biasogram: Visualization of Confounding Technical Bias in Gene Expression Data
Krzystanek, Marcin; Szallasi, Zoltan; Eklund, Aron C.
2013-01-01
Gene expression profiles of clinical cohorts can be used to identify genes that are correlated with a clinical variable of interest such as patient outcome or response to a particular drug. However, expression measurements are susceptible to technical bias caused by variation in extraneous factors such as RNA quality and array hybridization conditions. If such technical bias is correlated with the clinical variable of interest, the likelihood of identifying false positive genes is increased. Here we describe a method to visualize an expression matrix as a projection of all genes onto a plane defined by a clinical variable and a technical nuisance variable. The resulting plot indicates the extent to which each gene is correlated with the clinical variable or the technical variable. We demonstrate this method by applying it to three clinical trial microarray data sets, one of which identified genes that may have been driven by a confounding technical variable. This approach can be used as a quality control step to identify data sets that are likely to yield false positive results. PMID:23613961
Joshi, Prathamesh; Lele, Vikram; Mahajan, Pravin
2012-01-01
We report a case documenting fluorodeoxyglucose (FDG) accumulation in cervical, supraclavicular and axillary lymph nodes resulting from acute toxoplasmosis. A 50-year-old Indian female with history of non-Hodgkin's lymphoma (NHL) of left breast, postchemotherapy status, was found to have hypermetabolic right cervical, supraclavicular and axillary lymph nodes on a surveillance FDG positron emission tomography/computed tomography (PET/CT) scan. Her previous two PET/CT scans were unremarkable with no evidence of metabolically active disease. Therefore, a differential diagnosis of relapse of NHL versus infectious/inflammatory pathology was raised in the report. Biopsy of axillary lymph node demonstrated features characteristic of toxoplasmosis. The serological test results were also compatible with acute toxoplasmosis infection. Infective and inflammatory diseases are known to accumulate FDG, resulting in false positives for malignancy. This case demonstrates lymph nodal toxoplasmosis as a potential cause of false positive FDG PET/CT findings in patients with known malignancy and highlights the importance of histopathological and laboratory correlation for the accurate interpretation of FDG PET/CT scans.
Mbabazi, Phoebe; Hopkins, Heidi; Osilo, Emmanuel; Kalungu, Michael; Byakika-Kibwika, Pauline; Kamya, Moses R.
2015-01-01
Malaria rapid diagnostic tests (RDTs) may improve fever management in areas without microscopy. We compared the accuracy of histidine-rich protein 2 (HRP2) and Plasmodium lactate dehydrogenase (pLDH)-based RDTs, using expert microscopy as a gold standard, for initial diagnosis, treatment monitoring, and diagnosis of recurrent malaria in a cohort of children followed longitudinally in a high-transmission area in Uganda. For 305 initial fever episodes, sensitivity was 98% for HRP2 and 87% for pLDH, whereas specificity was 55% and 96%, respectively. The HRP2 gave 51% false-positive results on Day 28, whereas pLDH gave no false positives after Day 7. For 59 recurrent fever episodes during follow-up, sensitivity was 100% for HRP2 and 91% for pLDH, whereas specificity was 33% and 100%, respectively. The HRP2-based RDTs are useful for initial diagnosis of malaria caused by superior sensitivity; however, as a result of superior specificity, pLDH-based RDTs are more appropriate to monitor treatment and diagnose recurrent malaria. PMID:25624399
Flanagan, Emma C; Wong, Stephanie; Dutt, Aparna; Tu, Sicong; Bertoux, Maxime; Irish, Muireann; Piguet, Olivier; Rao, Sulakshana; Hodges, John R; Ghosh, Amitabha; Hornberger, Michael
2016-01-01
Episodic memory recall processes in Alzheimer's disease (AD) and behavioral variant frontotemporal dementia (bvFTD) can be similarly impaired, whereas recognition performance is more variable. A potential reason for this variability could be false-positive errors made on recognition trials and whether these errors are due to amnesia per se or a general over-endorsement of recognition items regardless of memory. The current study addressed this issue by analysing recognition performance on the Rey Auditory Verbal Learning Test (RAVLT) in 39 bvFTD, 77 AD and 61 control participants from two centers (India, Australia), as well as disinhibition assessed using the Hayling test. Whereas both AD and bvFTD patients were comparably impaired on delayed recall, bvFTD patients showed intact recognition performance in terms of the number of correct hits. However, both patient groups endorsed significantly more false-positives than controls, and bvFTD and AD patients scored equally poorly on a sensitivity index (correct hits-false-positives). Furthermore, measures of disinhibition were significantly associated with false positives in both groups, with a stronger relationship with false-positives in bvFTD. Voxel-based morphometry analyses revealed similar neural correlates of false positive endorsement across bvFTD and AD, with both patient groups showing involvement of prefrontal and Papez circuitry regions, such as medial temporal and thalamic regions, and a DTI analysis detected an emerging but non-significant trend between false positives and decreased fornix integrity in bvFTD only. These findings suggest that false-positive errors on recognition tests relate to similar mechanisms in bvFTD and AD, reflecting deficits in episodic memory processes and disinhibition. These findings highlight that current memory tests are not sufficient to accurately distinguish between bvFTD and AD patients.
False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.
Tenore, Peter L
2012-01-01
In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.
Marcomichelakis, J; Donaldson, R; Green, J; Joseph, S; Kelly, H B; Taggart, P; Somerville, W
1980-01-01
The value of exercise testing in detecting myocardial ischaemia resulting from coronary atheroma remains controversial. In order to increase the reliability of exercise testing, all its components (asymptomatic, haemodynamic, and electrocardiographic) have been scrutinised. In this study, concerned only with the electrocardiographic response to exercise, the incorporation of beta-blockade into the standard exercise procedure has improved specificity and predictive value without affecting sensitivity. Fifty patients with anginal pain and 50 asymptomatic subjects with an abnormal electrocardiogram were investigated by exercise testing before and after beta-blockade (oxprenolol). All subjects had coronary arteriograms and left ventriculograms, and the results of exercise testing were related to the presence or absence of obstructive coronary artery disease. Possible causes of false positive exercise tests were eliminated by echocardiography. Though beta-blockade was unreliable in distinguishing ischaemic from non-ischaemic resting electrocardiograms, it eliminated all the false positive electrocardiographic responses to exercise in both groups and did not abolish any of the true positive electrocardiographic responses. Thus, specificity and predictive value were improved without reduction in sensitivity. This technique may not necessarily be applicable to other groups of patients or to a random population, but the results of this study suggest it will be a useful additional routine procedure in the investigation of coronary heart disease. PMID:7437172
Maratou, Klio; Behmoaras, Jacques; Fewings, Chris; Srivastava, Prashant; D’Souza, Zelpha; Smith, Jennifer; Game, Laurence; Cook, Terence; Aitman, Tim
2010-01-01
Crescentic glomerulonephritis (CRGN) is a major cause of rapidly progressive renal failure for which the underlying genetic basis is unknown. WKY rats show marked susceptibility to CRGN, while Lewis rats are resistant. Glomerular injury and crescent formation are macrophage-dependent and mainly explained by seven quantitative trait loci (Crgn1-7). Here, we used microarray analysis in basal and lipopolysaccharide (LPS)-stimulated macrophages to identify genes that reside on pathways predisposing WKY rats to CRGN. We detected 97 novel positional candidates for the uncharacterised Crgn3-7. We identified 10 additional secondary effector genes with profound differences in expression between the two strains (>5-fold change, <1% False Discovery Rate) for basal and LPS-stimulated macrophages. Moreover, we identified 8 genes with differentially expressed alternatively spliced isoforms, by using an in depth analysis at probe-level that allowed us to discard false positives due to polymorphisms between the two rat strains. Pathway analysis identified several common linked pathways, enriched for differentially expressed genes, which affect macrophage activation. In summary, our results identify distinct macrophage transcriptome profiles between two rat strains that differ in susceptibility to glomerulonephritis, provide novel positional candidates for Crgn3-7, and define groups of genes that play a significant role in differential regulation of macrophage activity. PMID:21179115
Alegro, Maryana; Theofilas, Panagiotis; Nguy, Austin; Castruita, Patricia A; Seeley, William; Heinsen, Helmut; Ushizima, Daniela M; Grinberg, Lea T
2017-04-15
Immunofluorescence (IF) plays a major role in quantifying protein expression in situ and understanding cell function. It is widely applied in assessing disease mechanisms and in drug discovery research. Automation of IF analysis can transform studies using experimental cell models. However, IF analysis of postmortem human tissue relies mostly on manual interaction, often subjected to low-throughput and prone to error, leading to low inter and intra-observer reproducibility. Human postmortem brain samples challenges neuroscientists because of the high level of autofluorescence caused by accumulation of lipofuscin pigment during aging, hindering systematic analyses. We propose a method for automating cell counting and classification in IF microscopy of human postmortem brains. Our algorithm speeds up the quantification task while improving reproducibility. Dictionary learning and sparse coding allow for constructing improved cell representations using IF images. These models are input for detection and segmentation methods. Classification occurs by means of color distances between cells and a learned set. Our method successfully detected and classified cells in 49 human brain images. We evaluated our results regarding true positive, false positive, false negative, precision, recall, false positive rate and F1 score metrics. We also measured user-experience and time saved compared to manual countings. We compared our results to four open-access IF-based cell-counting tools available in the literature. Our method showed improved accuracy for all data samples. The proposed method satisfactorily detects and classifies cells from human postmortem brain IF images, with potential to be generalized for applications in other counting tasks. Copyright © 2017 Elsevier B.V. All rights reserved.
Quigley, S J; Linnane, B; Connellan, S; Ward, A; Ryan, P
2018-06-01
Significant gaps have been identified in parental understanding of CF newborn screening and the consequences of carrying an altered CF gene. Seven potential causes of psychosocial adversity arising from false positive newborn screening for CF have been identified. The current study aimed to increase parents understanding of CF, reduce their levels of stress, and investigate psychosocial adversity arising from false-positive screening. This national study was run over one year in the Republic of Ireland. Parents were recruited for the study following a diagnostic sweat test confirming their child carried a single altered CF gene. Parents were randomly assigned into a control and intervention group, with those in the intervention group receiving a carefully designed information pack. All parents took part in semi-structured interviews. Parents (n = 16) who received an information pack had significantly higher CF knowledge scores than parents (n = 16) in the control group. 66% of parents in the control group misunderstood the health implications of carrying an altered CF gene, no parents in the intervention group had the same misunderstanding. There was no significant difference in stress scores between the groups. Parents of infants who had more than one sweat test due to insufficient sweat quantity had higher overall stress percentiles (50%), than parents of infants who had one sweat test (30%), indicating greater parental stress. The combination of written and audio-visual information contained in the information pack successfully increased parents comprehension of CF. The study also evaluates the potential for psychosocial adversity following false positive newborn screening for CF.
NASA Astrophysics Data System (ADS)
Tsehay, Yohannes K.; Lay, Nathan S.; Roth, Holger R.; Wang, Xiaosong; Kwak, Jin Tae; Turkbey, Baris I.; Pinto, Peter A.; Wood, Brad J.; Summers, Ronald M.
2017-03-01
Prostate cancer (PCa) is the second most common cause of cancer related deaths in men. Multiparametric MRI (mpMRI) is the most accurate imaging method for PCa detection; however, it requires the expertise of experienced radiologists leading to inconsistency across readers of varying experience. To increase inter-reader agreement and sensitivity, we developed a computer-aided detection (CAD) system that can automatically detect lesions on mpMRI that readers can use as a reference. We investigated a convolutional neural network based deep-learing (DCNN) architecture to find an improved solution for PCa detection on mpMRI. We adopted a network architecture from a state-of-the-art edge detector that takes an image as an input and produces an image probability map. Two-fold cross validation along with a receiver operating characteristic (ROC) analysis and free-response ROC (FROC) were used to determine our deep-learning based prostate-CAD's (CADDL) performance. The efficacy was compared to an existing prostate CAD system that is based on hand-crafted features, which was evaluated on the same test-set. CADDL had an 86% detection rate at 20% false-positive rate while the top-down learning CAD had 80% detection rate at the same false-positive rate, which translated to 94% and 85% detection rate at 10 false-positives per patient on the FROC. A CNN based CAD is able to detect cancerous lesions on mpMRI of the prostate with results comparable to an existing prostate-CAD showing potential for further development.
Chardin, David; Nivaggioni, Guillaume; Viau, Philippe; Butori, Caherine; Padovani, Bernard; Grangeaon, Caroline; Razzouk-Cadet, Micheline
2017-06-01
Exogenous lipoid pneumonia is a rare condition due to abnormal presence of oily substances in the lungs. It is a rarely known cause for false positive FDG PET-CT results and can sometimes lead to invasive investigations. Searching and finding the source of the oily substance is one of the keys to the diagnosis. Inhalation of oily drugs during snorting has rarely been described. A patient with well controlled HIV infection was referred for an FDG PET-CT to assess extension of Kaposi's disease, recently removed from his right foot. The patient had no particular symptoms. Abnormal uptake of FDG was found in a suspicious lung nodule. An experienced radiologist thought the nodule was due to lipoid pneumonia. Bronchoalveolar lavage fluid did not contain lipid-laden macrophages but bronchoscopy showed violet lesions resembling Kaposi's disease lesions. Lobectomy was performed after a multidisciplinary discussion. Anatomopathological analysis revealed the nodule was due to lipoid pneumonia. The patient's quality of life did not diminish after the operation and he is still in good health. The source of the oily substance causing lipoid pneumonia was found after the surgery: the patient used to snort oily drugs. The presence of a suspicious lung nodule possibly due to lipoid pneumonia in a patient with known Kaposi's disease was difficult to untangle and lead to invasive surgery. It is possible that if a source of exogenous lipoid pneumonia had been found beforehand, surgery could have been prevented.
Wang, Yilin; Xiong, Lishou; Gong, Xiaorong; Li, Weimin; Zhang, Xiangsong; Chen, Minhu
2015-06-01
It has been reported that small intestinal bacterial overgrowth (SIBO) may lead to false positive diagnoses of lactose malabsorption (LM) in irritable bowel syndrome patients. The aim of this study was to determine the influence of SIBO on lactose hydrogen breath test (HBT) results in these patients. Diarrhea-predominant irritable bowel syndrome patients with abnormal lactose HBTs ingested a test meal containing (99m) Tc and lactose. The location of the test meal and the breath levels of hydrogen were recorded simultaneously by scintigraphic scanning and lactose HBT, respectively. The increase in hydrogen concentration was not considered to be caused by SIBO if ≥ 10% of (99m) Tc accumulated in the cecal region at the time or before of abnormal lactose HBT. LM was present in 84% (31/37) of irritable bowel syndrome patients. Twenty of these patients agreed to measurement of oro-cecal transit time. Only three patients (15%) with abnormal lactose HBT might have had SIBO. The median oro-cecal transit time between LM and lactose intolerance patients were 75 min and 45 min, respectively (Z=2.545, P=0.011). Most of irritable bowel syndrome patients with an abnormal lactose HBT had LM. SIBO had little impact on the interpretation of lactose HBTs. The patients with lactose intolerance had faster small intestinal transit than LM patients. © 2014 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.
Sievert, Lynnette L; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E
2010-01-01
The aims of this study were to test for a diurnal pattern in hot flashes in a multiethnic population living in a hot, humid environment and to examine the rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Study participants aged 45 to 55 years were recruited from the general population of Hilo, HI. Women wore a Biolog hot flash monitor (UFI, Morro Bay, CA), kept a diary for 24 hours, and also participated in 3-hour laboratory measures (n = 199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true-positive readings. Subjective hot flashes were considered the standard for computing false-positive and false-negative readings. True-positive, false-positive, and false-negative readings were compared across ethnic groups by chi analyses. Frequencies of sternal, nuchal, and subjective hot flashes peaked at 1500 +/- 1 hours with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true-positive measures, but nonsternal electrodes picked up more false-positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true-positive or false-positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false-negative measures). The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo were similar to results from more temperate environments. Lack of variation in sternal versus nonsternal measures and in true-positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns.
Sievert, Lynnette L.; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E.
2010-01-01
Objective To test for a diurnal pattern in hot flashes in a multi-ethnic population living in a hot, humid environment. To examine rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Methods Study participants aged 45–55 were recruited from the general population of Hilo, Hawaii. Women wore a Biolog hot flash monitor, kept a diary for 24-hours, and also participated in 3-hour laboratory measures (n=199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true positive readings. Subjective hot flashes were considered the standard for computing false positive and false negative readings. True positive, false positive, and false negative readings were compared across ethnic groups by chi-square analyses. Results Frequencies of sternal, nuchal and subjective hot flashes peaked at 15:00 ± 1 hour with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true positive measures, but non-sternal electrodes picked up more false positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true positive or false positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false negative measures). Conclusions The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo was similar to results from more temperate environments. Lack of variation in sternal vs. non-sternal measures, and in true positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns. PMID:20220538
Induction detection of concealed bulk banknotes
NASA Astrophysics Data System (ADS)
Fuller, Christopher; Chen, Antao
2011-10-01
Bulk cash smuggling is a serious issue that has grown in volume in recent years. By building on the magnetic characteristics of paper currency, induction sensing is found to be capable of quickly detecting large masses of banknotes. The results show that this method is effective in detecting bulk cash through concealing materials such as plastics, cardboards, fabrics and aluminum foil. The significant difference in the observed phase between the received signals caused by conducting materials and ferrite compounds, found in banknotes, provides a good indication that this process can overcome the interference by metal objects in a real sensing application. This identification strategy has the potential to not only detect the presence of banknotes, but also the number, while still eliminating false positives caused by metal objects.
Li, Bingshan; Leal, Suzanne M.
2008-01-01
Missing genotype data can increase false-positive evidence for linkage when either parametric or nonparametric analysis is carried out ignoring intermarker linkage disequilibrium (LD). Previously it was demonstrated by Huang et al. [1] that no bias occurs in this situation for affected sib-pairs with unrelated parents when either both parents are genotyped or genotype data is available for two additional unaffected siblings when parental genotypes are missing. However, this is not the case for autosomal recessive consanguineous pedigrees, where missing genotype data for any pedigree member within a consanguinity loop can increase false-positive evidence of linkage. False-positive evidence for linkage is further increased when cryptic consanguinity is present. The amount of false-positive evidence for linkage, and which family members aid in its reduction, is highly dependent on which family members are genotyped. When parental genotype data is available, the false-positive evidence for linkage is usually not as strong as when parental genotype data is unavailable. For a pedigree with an affected proband whose first-cousin parents have been genotyped, further reduction in the false-positive evidence of linkage can be obtained by including genotype data from additional affected siblings of the proband or genotype data from the proband's sibling-grandparents. For the situation, when parental genotypes are unavailable, false-positive evidence for linkage can be reduced by including genotype data from either unaffected siblings of the proband or the proband's married-in-grandparents in the analysis. PMID:18073490
Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L
2018-03-01
There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.
2011-01-01
Background The entomological inoculation rate (EIR) is an important indicator in estimating malaria transmission and the impact of vector control. To assess the EIR, the enzyme-linked immunosorbent assay (ELISA) to detect the circumsporozoite protein (CSP) is increasingly used. However, several studies have reported false positive results in this ELISA. The false positive results could lead to an overestimation of the EIR. The aim of present study was to estimate the level of false positivity among different anopheline species in Cambodia and Vietnam and to check for the presence of other parasites that might interact with the anti-CSP monoclonal antibodies. Methods Mosquitoes collected in Cambodia and Vietnam were identified and tested for the presence of sporozoites in head and thorax by using CSP-ELISA. ELISA positive samples were confirmed by a Plasmodium specific PCR. False positive mosquitoes were checked by PCR for the presence of parasites belonging to the Haemosporidia, Trypanosomatidae, Piroplasmida, and Haemogregarines. The heat-stability and the presence of the cross-reacting antigen in the abdomen of the mosquitoes were also checked. Results Specimens (N = 16,160) of seven anopheline species were tested by CSP-ELISA for Plasmodium falciparum and Plasmodium vivax (Pv210 and Pv247). Two new vector species were identified for the region: Anopheles pampanai (P. vivax) and Anopheles barbirostris (Plasmodium malariae). In 88% (155/176) of the mosquitoes found positive with the P. falciparum CSP-ELISA, the presence of Plasmodium sporozoites could not be confirmed by PCR. This percentage was much lower (28% or 5/18) for P. vivax CSP-ELISAs. False positive CSP-ELISA results were associated with zoophilic mosquito species. None of the targeted parasites could be detected in these CSP-ELISA false positive mosquitoes. The ELISA reacting antigen of P. falciparum was heat-stable in CSP-ELISA true positive specimens, but not in the false positives. The heat-unstable cross-reacting antigen is mainly present in head and thorax and almost absent in the abdomens (4 out of 147) of the false positive specimens. Conclusion The CSP-ELISA can considerably overestimate the EIR, particularly for P. falciparum and for zoophilic species. The heat-unstable cross-reacting antigen in false positives remains unknown. Therefore it is highly recommended to confirm all positive CSP-ELISA results, either by re-analysing the heated ELISA lysate (100°C, 10 min), or by performing Plasmodium specific PCR followed if possible by sequencing of the amplicons for Plasmodium species determination. PMID:21767376
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-13
... false positive match rate of 10 percent. Making the match mandatory for the States who did not perform... number of prisoners from 1995 to 2013 and assumed a 10 percent false positive match rate. Finally, we... matches are false positives. We estimate that mandatory matches at certification will identify an...
Methods for threshold determination in multiplexed assays
Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J
2014-06-24
Methods for determination of threshold values of signatures comprised in an assay are described. Each signature enables detection of a target. The methods determine a probability density function of negative samples and a corresponding false positive rate curve. A false positive criterion is established and a threshold for that signature is determined as a point at which the false positive rate curve intersects the false positive criterion. A method for quantitative analysis and interpretation of assay results together with a method for determination of a desired limit of detection of a signature in an assay are also described.
Yoon, Jung Hyun; Jung, Hae Kyoung; Lee, Jong Tae; Ko, Kyung Hee
2013-09-01
To investigate the factors that have an effect on false-positive or false-negative shear-wave elastography (SWE) results in solid breast masses. From June to December 2012, 222 breast lesions of 199 consecutive women (mean age: 45.3 ± 10.1 years; range, 21 to 88 years) who had been scheduled for biopsy or surgical excision were included. Greyscale ultrasound and SWE were performed in all women before biopsy. Final ultrasound assessments and SWE parameters (pattern classification and maximum elasticity) were recorded and compared with histopathology results. Patient and lesion factors in the 'true' and 'false' groups were compared. Of the 222 masses, 175 (78.8 %) were benign, and 47 (21.2 %) were malignant. False-positive rates of benign masses were significantly higher than false-negative rates of malignancy in SWE patterns, 36.6 % to 6.4 % (P < 0.001). Among both benign and malignant masses, factors showing significance among false SWE features were lesion size, breast thickness and lesion depth (all P < 0.05). All 47 malignant breast masses had SWE images of good quality. False SWE features were more significantly seen in benign masses. Lesion size, breast thickness and lesion depth have significance in producing false results, and this needs consideration in SWE image acquisition. • Shear-wave elastography (SWE) is widely used during breast imaging • At SWE, false-positive rates were significantly higher than false-negative rates • Larger size, breast thickness, depth and fair quality influences false-positive SWE features • Smaller size, larger breast thickness and depth influences false-negative SWE features.
Mordang, Jan-Jurre; Gubern-Mérida, Albert; den Heeten, Gerard; Karssemeijer, Nico
2016-04-01
In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists' detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8-1.0 were significantly different between the system without BACs removal and the system with BACs removal, 0.129 ± 0.009 versus 0.144 ± 0.008 (p<0.05), respectively. Additionally, the sensitivity at one false positive per 50 cases and one false positive per 25 cases increased as well, 37% versus 51% (p<0.05) and 58% versus 67% (p<0.05) sensitivity, respectively. Additionally, the CADe system with BACs removal reduces the number of false positives per case by 29% on average. The same sensitivity at one false positive per 50 cases in the CADe system without BACs removal can be achieved at one false positive per 80 cases in the CADe system with BACs removal. By using dedicated algorithms to detect and remove breast arterial calcifications, the performance of CADe systems can be improved, in particular, at false positive rates representative for operating points used in screening.
Evaluation of recombinant proteins of Burkholderia mallei for serodiagnosis of glanders.
Pal, Vijai; Kumar, Subodh; Malik, Praveen; Rai, Ganga Prasad
2012-08-01
Glanders is a contagious disease caused by the Gram-negative bacillus Burkholderia mallei. The number of equine glanders outbreaks has increased steadily during the last decade. The disease must be reported to the Office International des Epizooties, Paris, France. Glanders serodiagnosis is hampered by the considerable number of false positives and negatives of the internationally prescribed tests. The major problem leading to the low sensitivity and specificity of the complement fixation test (CFT) and enzyme-linked immunosorbent assay (ELISA) has been linked to the test antigens currently used, i.e., crude preparations of whole cells. False-positive results obtained from other diagnostic tests utilizing crude antigens lead to financial losses to animal owners, and false-negative results can turn a risk into a possible threat. In this study, we report on the identification of diagnostic targets using bioinformatics tools for serodiagnosis of glanders. The identified gene sequences were cloned and expressed as recombinant proteins. The purified recombinant proteins of B. mallei were used in an indirect ELISA format for serodiagnosis of glanders. Two recombinant proteins, 0375H and 0375TH, exhibited 100% sensitivity and specificity for glanders diagnosis. The proteins also did not cross-react with sera from patients with the closely related disease melioidosis. The results of this investigation highlight the potential of recombinant 0375H and 0375TH proteins in specific and sensitive diagnosis of glanders.
Evaluation of Recombinant Proteins of Burkholderia mallei for Serodiagnosis of Glanders
Kumar, Subodh; Malik, Praveen
2012-01-01
Glanders is a contagious disease caused by the Gram-negative bacillus Burkholderia mallei. The number of equine glanders outbreaks has increased steadily during the last decade. The disease must be reported to the Office International des Epizooties, Paris, France. Glanders serodiagnosis is hampered by the considerable number of false positives and negatives of the internationally prescribed tests. The major problem leading to the low sensitivity and specificity of the complement fixation test (CFT) and enzyme-linked immunosorbent assay (ELISA) has been linked to the test antigens currently used, i.e., crude preparations of whole cells. False-positive results obtained from other diagnostic tests utilizing crude antigens lead to financial losses to animal owners, and false-negative results can turn a risk into a possible threat. In this study, we report on the identification of diagnostic targets using bioinformatics tools for serodiagnosis of glanders. The identified gene sequences were cloned and expressed as recombinant proteins. The purified recombinant proteins of B. mallei were used in an indirect ELISA format for serodiagnosis of glanders. Two recombinant proteins, 0375H and 0375TH, exhibited 100% sensitivity and specificity for glanders diagnosis. The proteins also did not cross-react with sera from patients with the closely related disease melioidosis. The results of this investigation highlight the potential of recombinant 0375H and 0375TH proteins in specific and sensitive diagnosis of glanders. PMID:22695165
Effects of depressive disorder on false memory for emotional information.
Yeh, Zai-Ting; Hua, Mau-Sun
2009-01-01
This study explored with a false memory paradigm whether (1) depressed patients revealed more false memories and (2) whether more negative false than positive false recognition existed in subjects with depressive disorders. Thirty-two patients suffering from a major depressive episode (DSM-IV criteria), and 30 age- and education-matched normal control subjects participated in this study. After the presentation of a list of positive, negative, and neutral association items in the learning phase, subjects were asked to give a yes/no response in the recognition phase. They were also asked to rate 81 recognition items with emotional valence scores. The results revealed more negative false memories in the clinical depression group than in the normal control group; however, we did not find more negative false memories than positive ones in patients. When compared with the normal group, a more conservative response criterion for positive items was evident in patient groups. It was also found that when compared with the normal group, the subjects in the depression group perceived the positive items as less positive. On the basis of present results, it is suggested that depressed subjects judged the emotional information with criteria different from normal individuals, and patients' emotional memory intensity is attenuated by their mood.
Johnson, Susan L; Tabaei, Bahman P; Herman, William H
2005-02-01
To simulate the outcomes of alternative strategies for screening the U.S. population 45-74 years of age for type 2 diabetes. We simulated screening with random plasma glucose (RPG) and cut points of 100, 130, and 160 mg/dl and a multivariate equation including RPG and other variables. Over 15 years, we simulated screening at intervals of 1, 3, and 5 years. All positive screening tests were followed by a diagnostic fasting plasma glucose or an oral glucose tolerance test. Outcomes include the numbers of false-negative, true-positive, and false-positive screening tests and the direct and indirect costs. At year 15, screening every 3 years with an RPG cut point of 100 mg/dl left 0.2 million false negatives, an RPG of 130 mg/dl or the equation left 1.3 million false negatives, and an RPG of 160 mg/dl left 2.8 million false negatives. Over 15 years, the absolute difference between the most sensitive and most specific screening strategy was 4.5 million true positives and 476 million false-positives. Strategies using RPG cut points of 130 mg/dl or the multivariate equation every 3 years identified 17.3 million true positives; however, the equation identified fewer false-positives. The total cost of the most sensitive screening strategy was $42.7 billion and that of the most specific strategy was $6.9 billion. Screening for type 2 diabetes every 3 years with an RPG cut point of 130 mg/dl or the multivariate equation provides good yield and minimizes false-positive screening tests and costs.
Breast cancer detection risk in screening mammography after a false-positive result.
Castells, X; Román, M; Romero, A; Blanch, J; Zubizarreta, R; Ascunce, N; Salas, D; Burón, A; Sala, M
2013-02-01
False-positives are a major concern in breast cancer screening. However, false-positives have been little evaluated as a prognostic factor for cancer detection. Our aim was to evaluate the association of false-positive results with the cancer detection risk in subsequent screening participations over a 17-year period. This is a retrospective cohort study of 762,506 women aged 45-69 years, with at least two screening participations, who underwent 2,594,146 screening mammograms from 1990 to 2006. Multilevel discrete-time hazard models were used to estimate the adjusted odds ratios (OR) of breast cancer detection in subsequent screening participations in women with false-positive results. False-positives involving a fine-needle aspiration cytology or a biopsy had a higher cancer detection risk than those involving additional imaging procedures alone (OR = 2.69; 95%CI: 2.28-3.16 and OR = 1.81; 95%CI: 1.70-1.94, respectively). The risk of cancer detection increased substantially if women with cytology or biopsy had a familial history of breast cancer (OR = 4.64; 95%CI: 3.23-6.66). Other factors associated with an increased cancer detection risk were age 65-69 years (OR = 1.84; 95%CI: 1.67-2.03), non-attendance at the previous screening invitation (OR = 1.26; 95%CI: 1.11-1.43), and having undergone a previous benign biopsy outside the screening program (OR = 1.24; 95%CI: 1.13-1.35). Women with a false-positive test have an increased risk of cancer detection in subsequent screening participations, especially those with a false-positive result involving cytology or biopsy. Understanding the factors behind this association could provide valuable information to increase the effectiveness of breast cancer screening. Copyright © 2012 Elsevier Ltd. All rights reserved.
Psychological distress in U.S. women who have experienced false-positive mammograms.
Jatoi, Ismail; Zhu, Kangmin; Shah, Mona; Lawrence, William
2006-11-01
In the United States, approximately 10.7% of all screening mammograms lead to a false-positive result, but the overall impact of false-positives on psychological well-being is poorly understood. Data were analyzed from the 2000 U.S. National Health Interview Survey (NHIS), the most recent national survey that included a cancer control module. Study subjects were 9,755 women who ever had a mammogram, of which 1,450 had experienced a false-positive result. Psychological distress was assessed using the validated K6 questionnaire and logistic regression was used to discern any association with previous false-positive mammograms. In a multivariate analysis, women who had indicated a previous false-positive mammogram were more likely to report feeling sad (OR = 1.18, 95% CI, 1.03-1.35), restless (OR = 1.23, 95% CI, 1.08-1.40), worthless (OR = 1.27, 95% CI, 1.04-1.54), and finding that everything was an effort (OR = 1.27, 95% CI, 1.10-1.47). These women were also more likely to have seen a mental health professional in the 12 months preceding the survey (OR = 1.28, 95% CI, 1.03-1.58) and had a higher composite score on all items of the K6 scale (P < 0.0001), a reflection of increased psychological distress. Analyses by age and race revealed that, among women who had experienced false-positives, younger women were more likely to feel that everything was an effort, and blacks were more likely to feel restless. In a random sampling of the U.S. population, women who had previously experienced false-positive mammograms were more likely to report symptoms of anxiety and depression.
Fox, Stefan; Strasdeit, Henry
2017-01-01
The "Rare Earth" hypothesis-put forward by Ward and Brownlee in their 2000 book of the same title-states that prokaryote-type organisms may be common in the universe but animals and higher plants are exceedingly rare. If this idea is correct, the search for extraterrestrial life is essentially the search for microorganisms. Various indicators may be used to detect extant or extinct microbial life beyond Earth. Among them are chemical biosignatures, such as biomolecules and stable isotope ratios. The present minireview focuses on the major problems associated with the identification of chemical biosignatures. Two main types of misinterpretation are distinguished, namely false positive and false negative results. The former can be caused by terrestrial biogenic contaminants or by abiotic products. Terrestrial contamination is a common problem in space missions that search for biosignatures on other planets and moons. Abiotic organics can lead to false positive results if erroneously interpreted as biomolecules, but also to false negatives, for example when an abiotic source obscures a less productive biological one. In principle, all types of putative chemical biosignatures are prone to misinterpretation. Some, however, are more reliable ("stronger") than others. These include: (i) homochiral polymers of defined length and sequence, comparable to proteins and polynucleotides; (ii) enantiopure compounds; (iii) the existence of only a subset of molecules when abiotic syntheses would produce a continuous range of molecules; the proteinogenic amino acids constitute such a subset. These considerations are particularly important for life detection missions to solar system bodies such as Mars, Europa, and Enceladus.
Favaloro, Emmanuel J; McCaughan, Georgia; Mohammed, Soma; Lau, Kun Kan Edwin; Gemmell, Rosalie; Cavanaugh, Lauren; Donikian, Dea; Kondo, Mayuko; Brighton, Timothy; Pasalic, Leonardo
2018-04-17
Heparin induced thrombocytopenia (HIT) is a rare but potentially fatal complication of heparin therapy, which in a proportion of patients causes platelet activation and thrombosis. Initial clinical assessment of the likelihood of HIT is facilitated by laboratory testing to confirm or exclude HIT. This prospective investigation was performed over an 18-month period, and has involved testing of over 300 test samples from over 100 consecutive patients. Clinical assessment by 4T score was supplemented by laboratory tests that comprised both immunological [lateral flow ('STiC'), chemiluminescence (AcuStar; HIT-IgG (PF4-H) ), ELISA (Asserachrom HPIA IgG)] and functional assays [SRA, platelet aggregation using whole blood ('Multiplate') and platelet rich plasma ('LTA')]. We observed both false positive and false negative test findings with most assays. Overall, the whole blood aggregation method provided a reasonable alternative to SRA for identifying functional HIT. STiC, AcuStar and ELISA procedures were fairly comparable in terms of screening for HIT, although STiC and AcuStar both yielded false negatives, albeit also resulting in fewer false positives than ELISA. The 4T score had less utility in our patient cohort than we were expecting, although there was an association with the likelihood of HIT. Nevertheless, we accept that our observations are based on limited test numbers. In conclusion, no single approach (clinical or laboratory) was associated with optimal sensitivity or specificity of HIT exclusion or identification, and thus, a combination of clinical evaluation and laboratory testing will best ensure the accuracy of diagnosis. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.
Fox, Stefan; Strasdeit, Henry
2017-01-01
The “Rare Earth” hypothesis—put forward by Ward and Brownlee in their 2000 book of the same title—states that prokaryote-type organisms may be common in the universe but animals and higher plants are exceedingly rare. If this idea is correct, the search for extraterrestrial life is essentially the search for microorganisms. Various indicators may be used to detect extant or extinct microbial life beyond Earth. Among them are chemical biosignatures, such as biomolecules and stable isotope ratios. The present minireview focuses on the major problems associated with the identification of chemical biosignatures. Two main types of misinterpretation are distinguished, namely false positive and false negative results. The former can be caused by terrestrial biogenic contaminants or by abiotic products. Terrestrial contamination is a common problem in space missions that search for biosignatures on other planets and moons. Abiotic organics can lead to false positive results if erroneously interpreted as biomolecules, but also to false negatives, for example when an abiotic source obscures a less productive biological one. In principle, all types of putative chemical biosignatures are prone to misinterpretation. Some, however, are more reliable (“stronger”) than others. These include: (i) homochiral polymers of defined length and sequence, comparable to proteins and polynucleotides; (ii) enantiopure compounds; (iii) the existence of only a subset of molecules when abiotic syntheses would produce a continuous range of molecules; the proteinogenic amino acids constitute such a subset. These considerations are particularly important for life detection missions to solar system bodies such as Mars, Europa, and Enceladus. PMID:28970819
Nelson, Heidi D; Pappas, Miranda; Cantor, Amy; Griffin, Jessica; Daeges, Monica; Humphrey, Linda
2016-02-16
In 2009, the U.S. Preventive Services Task Force recommended biennial mammography screening for women aged 50 to 74 years and selective screening for those aged 40 to 49 years. To review studies of screening in average-risk women with mammography, magnetic resonance imaging, or ultrasonography that reported on false-positive results, overdiagnosis, anxiety, pain, and radiation exposure. MEDLINE and Cochrane databases through December 2014. English-language systematic reviews, randomized trials, and observational studies of screening. Investigators extracted and confirmed data from studies and dual-rated study quality. Discrepancies were resolved through consensus. Based on 2 studies of U.S. data, 10-year cumulative rates of false-positive mammography results and biopsies were higher with annual than biennial screening (61% vs. 42% and 7% vs. 5%, respectively) and for women aged 40 to 49 years, those with dense breasts, and those using combination hormone therapy. Twenty-nine studies using different methods reported overdiagnosis rates of 0% to 54%; rates from randomized trials were 11% to 22%. Women with false-positive results reported more anxiety, distress, and breast cancer-specific worry, although results varied across 80 observational studies. Thirty-nine observational studies indicated that some women reported pain during mammography (1% to 77%); of these, 11% to 46% declined future screening. Models estimated 2 to 11 screening-related deaths from radiation-induced cancer per 100,000 women using digital mammography, depending on age and screening interval. Five observational studies of tomosynthesis and mammography indicated increased biopsies but reduced recalls compared with mammography alone. Studies of overdiagnosis were highly heterogeneous, and estimates varied depending on the analytic approach. Studies of anxiety and pain used different outcome measures. Radiation exposure was based on models. False-positive results are common and are higher for annual screening, younger women, and women with dense breasts. Although overdiagnosis, anxiety, pain, and radiation exposure may cause harm, their effects on individual women are difficult to estimate and vary widely. Agency for Healthcare Research and Quality.
NASA Astrophysics Data System (ADS)
Morton, Timothy D.; Bryson, Stephen T.; Coughlin, Jeffrey L.; Rowe, Jason F.; Ravichandran, Ganesh; Petigura, Erik A.; Haas, Michael R.; Batalha, Natalie M.
2016-05-01
We present astrophysical false positive probability calculations for every Kepler Object of Interest (KOI)—the first large-scale demonstration of a fully automated transiting planet validation procedure. Out of 7056 KOIs, we determine that 1935 have probabilities <1% of being astrophysical false positives, and thus may be considered validated planets. Of these, 1284 have not yet been validated or confirmed by other methods. In addition, we identify 428 KOIs that are likely to be false positives, but have not yet been identified as such, though some of these may be a result of unidentified transit timing variations. A side product of these calculations is full stellar property posterior samplings for every host star, modeled as single, binary, and triple systems. These calculations use vespa, a publicly available Python package that is able to be easily applied to any transiting exoplanet candidate.
Radioiodine therapy for thyroid cancer depicted uterine leiomyoma.
Hirata, Kenji; Shiga, Tohru; Kubota, Kanako C; Okamoto, Shozo; Kamibayashi, Tomohito; Tamaki, Nagara
2009-03-01
A 55-year-old woman underwent radioiodine therapy for papillary carcinoma of the thyroid. Post-therapeutic I-131 scan revealed radioiodine uptake in the pelvic region and in the thyroid bed. CT revealed a huge mass connected to the uterus. The tumor was operated on and histologically proven to be a leiomyoma of the uterus. Some physiological conditions or nonthyroidal diseases can cause false positives in patients with postoperative thyroid cancer. We suggest that uterine leiomyoma might be added to the pitfall list, although the mechanism of I-131 uptake remains unclear.
How to limit false positives in environmental DNA and metabarcoding?
Ficetola, Gentile Francesco; Taberlet, Pierre; Coissac, Eric
2016-05-01
Environmental DNA (eDNA) and metabarcoding are boosting our ability to acquire data on species distribution in a variety of ecosystems. Nevertheless, as most of sampling approaches, eDNA is not perfect. It can fail to detect species that are actually present, and even false positives are possible: a species may be apparently detected in areas where it is actually absent. Controlling false positives remains a main challenge for eDNA analyses: in this issue of Molecular Ecology Resources, Lahoz-Monfort et al. () test the performance of multiple statistical modelling approaches to estimate the rate of detection and false positives from eDNA data. Here, we discuss the importance of controlling for false detection from early steps of eDNA analyses (laboratory, bioinformatics), to improve the quality of results and allow an efficient use of the site occupancy-detection modelling (SODM) framework for limiting false presences in eDNA analysis. © 2016 John Wiley & Sons Ltd.
Sgoifo Rossi, C A; Arioli, F; Bassini, A; Chiesa, L M; Dell'Orto, V; Montana, M; Pompa, G
2004-08-01
European Directive 96/22/EC, which controls veterinary residues in animals, does not permit the presence of synthetic growth promoters in products of animal origin or in livestock. Boldenone is categorized in class A3 (growth promoters -- steroids) and is thus a banned substance. Testing of veal urine for banned substances is part of the European Union statutory programme for animals going into the food chain. In relation to this monitoring, three studies were conducted to investigate the apparent presence of the banned growth promoter boldenone in veal urine, which was suspected as being caused by interference from faecal contamination of the sample. In the first study, urine samples were collected at different times (time 0 and after 30 min) using (1) a conventional zoonotechnical apron and (2) a technique designed specifically to avoid faecal contamination ('kettle'). This resulted in samples that were, respectively, positive and negative for the presence of alpha-boldenone (alpha-BOL). In a second study, urine samples negative to alpha-BOL were collected from eight veal calves, but became positive after deliberate faecal contamination. In a third study, data obtained from the Italian RNP (Residual National Program) indicated that 18.1% of 3295 urine samples collected using the zootechnical apron were positive for alpha-BOL and 2.1% for beta-boldenone (beta-BOL), whilst of 902 samples collected using the kettle, beta-BOL was not detected in any samples and only 0.2% were positive to alpha-BOL, in concentrations lower than 2 ng ml(-1). These results further support the supposition that faecal contamination of the urine during sample collection can lead to false-positive results during boldenone analysis.
Abad-Franch, Fernando; Valença-Barbosa, Carolina; Sarquis, Otília; Lima, Marli M.
2014-01-01
Background Vector-borne diseases are major public health concerns worldwide. For many of them, vector control is still key to primary prevention, with control actions planned and evaluated using vector occurrence records. Yet vectors can be difficult to detect, and vector occurrence indices will be biased whenever spurious detection/non-detection records arise during surveys. Here, we investigate the process of Chagas disease vector detection, assessing the performance of the surveillance method used in most control programs – active triatomine-bug searches by trained health agents. Methodology/Principal Findings Control agents conducted triplicate vector searches in 414 man-made ecotopes of two rural localities. Ecotope-specific ‘detection histories’ (vectors or their traces detected or not in each individual search) were analyzed using ordinary methods that disregard detection failures and multiple detection-state site-occupancy models that accommodate false-negative and false-positive detections. Mean (±SE) vector-search sensitivity was ∼0.283±0.057. Vector-detection odds increased as bug colonies grew denser, and were lower in houses than in most peridomestic structures, particularly woodpiles. False-positive detections (non-vector fecal streaks misidentified as signs of vector presence) occurred with probability ∼0.011±0.008. The model-averaged estimate of infestation (44.5±6.4%) was ∼2.4–3.9 times higher than naïve indices computed assuming perfect detection after single vector searches (11.4–18.8%); about 106–137 infestation foci went undetected during such standard searches. Conclusions/Significance We illustrate a relatively straightforward approach to addressing vector detection uncertainty under realistic field survey conditions. Standard vector searches had low sensitivity except in certain singular circumstances. Our findings suggest that many infestation foci may go undetected during routine surveys, especially when vector density is low. Undetected foci can cause control failures and induce bias in entomological indices; this may confound disease risk assessment and mislead program managers into flawed decision making. By helping correct bias in naïve indices, the approach we illustrate has potential to critically strengthen vector-borne disease control-surveillance systems. PMID:25233352
Kurucz, Nina; Markey, Peter; Draper, Anthony; Melville, Lorna; Weir, Richard; Davis, Steven; Warchot, Allan; Boyd, Rowena; Stokeld, Danielle
2016-02-01
Between October 2012 and October 2013, unprecedented high numbers of Barmah Forest virus (BFV) disease cases were reported in the Northern Territory (NT). An investigation was launched by the NT Department of Health in cooperation with the Department of Primary Industry and Fisheries and the Department of Land Resource Management to investigate possible causes for this phenomenon. The investigation included virus isolations from mosquitoes collected in Darwin urban areas, BFV antibody testing in peri-urban small mammals and a human BFV disease case series investigation of recent cases. No BFV was isolated from the 4641 mosquitoes tested, none of the mammals tested positive for BFV antibodies, and the high BFV disease case numbers did not correlate with the relatively low mosquito vector numbers trapped in 2012-2013. It was estimated that up to 89% of the 79 human cases investigated did not have an acute arboviral illness and therefore had tested falsely positive. An Alere PanBio BFV immunoglobulin M enzyme-linked immunosorbent assay test kit is generally used to test for BFV, with the BFV disease case definition based on immunoglobulin M positives only. Other jurisdictions in Australia also reported high numbers of BFV disease cases, with the majority of the cases suspected to be false positives. Therefore, current testing methods need to be revised to reflect the true numbers of BFV disease cases occurring in Australia and to provide correct diagnoses for patients.
Assessment of clinical scoring systems for the diagnosis of Williams-Beuren syndrome.
Leme, D E S; Souza, D H; Mercado, G; Pastene, E; Dias, A; Moretti-Ferreira, D
2013-09-04
Williams-Beuren syndrome (WBS) is a genetic disorder characterized by physical and intellectual developmental delay, associated with congenital heart disease and facial dysmorphism. WBS is caused by a microdeletion on chromosome 7 (7q11.23), which encompasses the elastin (ELN) gene and about 27 other genes. The gold standard for WBS laboratory diagnosis is FISH (fluorescence in situ hybridization), which is very costly. As a possible alternative, we investigated the accuracy of three clinical diagnostic scoring systems in 250 patients with WBS diagnosed by FISH. We concluded that all three systems could be used for the clinical diagnosis of WBS, but they all gave a low percentage of false-positive (6.0-9.2%) and false-negative (0.8-4.0%) results. Therefore, their use should be associated with FISH testing.
Shi, Zhenghao; Ma, Jiejue; Feng, Yaning; He, Lifeng; Suzuki, Kenji
2015-11-01
MTANN (Massive Training Artificial Neural Network) is a promising tool, which applied to eliminate false-positive for thoracic CT in recent years. In order to evaluate whether this method is feasible to eliminate false-positive of different CAD schemes, especially, when it is applied to commercial CAD software, this paper evaluate the performance of the method for eliminating false-positives produced by three different versions of commercial CAD software for lung nodules detection in chest radiographs. Experimental results demonstrate that the approach is useful in reducing FPs for different computer aided lung nodules detection software in chest radiographs.
NASA Astrophysics Data System (ADS)
Ikedo, Yuji; Fukuoka, Daisuke; Hara, Takeshi; Fujita, Hiroshi; Takada, Etsuo; Endo, Tokiko; Morita, Takako
2007-03-01
The comparison of left and right mammograms is a common technique used by radiologists for the detection and diagnosis of masses. In mammography, computer-aided detection (CAD) schemes using bilateral subtraction technique have been reported. However, in breast ultrasonography, there are no reports on CAD schemes using comparison of left and right breasts. In this study, we propose a scheme of false positive reduction based on bilateral subtraction technique in whole breast ultrasound images. Mass candidate regions are detected by using the information of edge directions. Bilateral breast images are registered with reference to the nipple positions and skin lines. A false positive region is detected based on a comparison of the average gray values of a mass candidate region and a region with the same position and same size as the candidate region in the contralateral breast. In evaluating the effectiveness of the false positive reduction method, three normal and three abnormal bilateral pairs of whole breast images were employed. These abnormal breasts included six masses larger than 5 mm in diameter. The sensitivity was 83% (5/6) with 13.8 (165/12) false positives per breast before applying the proposed reduction method. By applying the method, false positives were reduced to 4.5 (54/12) per breast without removing a true positive region. This preliminary study indicates that the bilateral subtraction technique is effective for improving the performance of a CAD scheme in whole breast ultrasound images.
Sherlock Holmes and child psychopathology assessment approaches: the case of the false-positive.
Jensen, P S; Watanabe, H
1999-02-01
To explore the relative value of various methods of assessing childhood psychopathology, the authors compared 4 groups of children: those who met criteria for one or more DSM diagnoses and scored high on parent symptom checklists, those who met psychopathology criteria on either one of these two assessment approaches alone, and those who met no psychopathology assessment criterion. Parents of 201 children completed the Child Behavior Checklist (CBCL), after which children and parents were administered the Diagnostic Interview Schedule for Children (version 2.1). Children and parents also completed other survey measures and symptom report inventories. The 4 groups of children were compared against "external validators" to examine the merits of "false-positive" and "false-negative" cases. True-positive cases (those that met DSM criteria and scored high on the CBCL) differed significantly from the true-negative cases on most external validators. "False-positive" and "false-negative" cases had intermediate levels of most risk factors and external validators. "False-positive" cases were not normal per se because they scored significantly above the true-negative group on a number of risk factors and external validators. A similar but less marked pattern was noted for "false-negatives." Findings call into question whether cases with high symptom checklist scores despite no formal diagnoses should be considered "false-positive." Pending the availability of robust markers for mental illness, researchers and clinicians must resist the tendency to reify diagnostic categories or to engage in arcane debates about the superiority of one assessment approach over another.
Jia, Qiang; Meng, Zhaowei; Tan, Jian; Zhang, Guizhi; He, Yajing; Sun, Haoran; Yu, Chunshui; Li, Dong; Zheng, Wei; Wang, Renfei; Wang, Shen; Li, Xue; Zhang, Jianping; Hu, Tianpeng; Liu, N A; Upadhyaya, Arun
2015-11-01
Iodine-131 (I-131) therapy and post-therapy I-131 scanning are essential in the management of differentiated thyroid cancer (DTC). However, pathological false positive I-131 scans can lead to misdiagnosis and inappropriate I-131 treatment. This retrospective study aimed to investigate the best imaging modality for the diagnosis of pathological false positive I-131 scans in a DTC patient cohort, and to determine its incidence. DTC patient data archived from January 2008 to January 2010 was retrieved. Post-therapeutic I-131 scans were conducted and interpreted. The imaging modalities of magnetic resonance imaging (MRI), computed tomography and ultrasonography were applied and compared to check all suspected lesions. Biopsy or needle aspiration was conducted for patients who consented to the acquisition of histopathological confirmation. Data for 156 DTC patients were retrieved. Only 6 cases of pathological false-positives were found among these (incidence, 3.85%), which included 3 cases of thymic hyperplasia in the mediastinum, 1 case of pleomorphic adenoma in the parapharyngeal space and 1 case of thyroglossal duct cyst in the neck. MRI was demonstrated as the best imaging modality for diagnosis due to its superior soft tissue resolution. However, no imaging modality was able to identify the abdominal false positive-lesions observed in 2 cases, one of whom also had thymic hyperplasia. In conclusion, pathological false positive I-131 scans occurred with an incidence of 3.85%. MRI was the best imaging modality for diagnosing these pathological false-positives.
Tan, Alai; Freeman, Daniel H; Goodwin, James S; Freeman, Jean L
2006-12-01
The accuracy of mammography reading varies among radiologists. We conducted a population-based assessment on radiologist variation in false- positive rates of screening mammography and its associated radiologist characteristics. About 27,394 screening mammograms interpreted by 1067 radiologists were identified from a 5% non-cancer sample of Medicare claims during 1998-1999. The data were linked to the American Medical Association Masterfile to obtain radiologist characteristics. Multilevel logistic regression models were used to examine the radiologist variation in false-positive rates of screening mammography and the associated radiologist characteristics. Radiologists varied substantially in the false-positive rates of screening mammography (ranging from 1.5 to 24.1%, adjusting for patient characteristics). A longer time period since graduation is associated with lower false-positive rates (odds ratio [OR] for every 10 years increase: 0.87, 95% Confidence Interval [CI], 0.81-0.94) and female radiologists had higher false-positive rates than male radiologists (OR = 1.25, 95% CI, 1.05-1.49), adjusting for patient and other radiologist characteristics. The unmeasured factors contributed to about 90% of the between-radiologist variance. Radiologists varied greatly in accuracy of mammography reading. Female and more recently trained radiologists had higher false-positive rates. The variation among radiologists was largely due to unmeasured factors, especially unmeasured radiologist factors. If our results are confirmed in further studies, they suggest that system-level interventions would be required to reduce variation in mammography interpretation.
Imberger, Georgina; Thorlund, Kristian; Gluud, Christian; Wetterslev, Jørn
2016-08-12
Many published meta-analyses are underpowered. We explored the role of trial sequential analysis (TSA) in assessing the reliability of conclusions in underpowered meta-analyses. We screened The Cochrane Database of Systematic Reviews and selected 100 meta-analyses with a binary outcome, a negative result and sufficient power. We defined a negative result as one where the 95% CI for the effect included 1.00, a positive result as one where the 95% CI did not include 1.00, and sufficient power as the required information size for 80% power, 5% type 1 error, relative risk reduction of 10% or number needed to treat of 100, and control event proportion and heterogeneity taken from the included studies. We re-conducted the meta-analyses, using conventional cumulative techniques, to measure how many false positives would have occurred if these meta-analyses had been updated after each new trial. For each false positive, we performed TSA, using three different approaches. We screened 4736 systematic reviews to find 100 meta-analyses that fulfilled our inclusion criteria. Using conventional cumulative meta-analysis, false positives were present in seven of the meta-analyses (7%, 95% CI 3% to 14%), occurring more than once in three. The total number of false positives was 14 and TSA prevented 13 of these (93%, 95% CI 68% to 98%). In a post hoc analysis, we found that Cochrane meta-analyses that are negative are 1.67 times more likely to be updated (95% CI 0.92 to 2.68) than those that are positive. We found false positives in 7% (95% CI 3% to 14%) of the included meta-analyses. Owing to limitations of external validity and to the decreased likelihood of updating positive meta-analyses, the true proportion of false positives in meta-analysis is probably higher. TSA prevented 93% of the false positives (95% CI 68% to 98%). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Working memory affects false memory production for emotional events.
Mirandola, Chiara; Toffalini, Enrico; Ciriello, Alfonso; Cornoldi, Cesare
2017-01-01
Whereas a link between working memory (WM) and memory distortions has been demonstrated, its influence on emotional false memories is unclear. In two experiments, a verbal WM task and a false memory paradigm for negative, positive or neutral events were employed. In Experiment 1, we investigated individual differences in verbal WM and found that the interaction between valence and WM predicted false recognition, with negative and positive material protecting high WM individuals against false remembering; the beneficial effect of negative material disappeared in low WM participants. In Experiment 2, we lowered the WM capacity of half of the participants with a double task request, which led to an overall increase in false memories; furthermore, consistent with Experiment 1, the increase in negative false memories was larger than that of neutral or positive ones. It is concluded that WM plays a critical role in determining false memory production, specifically influencing the processing of negative material.
Lourenço, Felipe Rebello; Botelho, Túlia De Souza; Pinto, Terezinha De Jesus Andreoli
2012-01-01
The limulus amebocyte lysate (LAL) test is the simplest and most widely used procedure for detection of endotoxin in parenteral drugs. The LAL test demands optimal pH, ionic strength, temperature, and time of incubation. Slight changes in these parameters may increase the frequency of false-positive responses and the estimated uncertainty of the LAL test. The aim of this paper is to evaluate how changes in the pH, temperature, and time of incubation affect the occurrence of false-positive responses in the LAL test. LAL tests were performed in nominal conditions (37 °C, 60 min, and pH 7) and in different conditions of temperature (36 °C and 38 °C), time of incubation (58 and 62 min), and pH (6 and 8). Slight differences in pH increase the frequency of false-positive responses 5-fold (relative risk 5.0), resulting in an estimated of uncertainty 7.6%. Temperature and time of incubation affect the LAL test less, showing relative risks of 1.5 and 1.0, respectively. Estimated uncertainties in 36 °C or 38 °C temperatures and 58 or 62 min of incubation were found to be 2.0% and 1.0%, respectively. Simultaneous differences in these parameters significantly increase the frequency of false-positive responses. The limulus amebocyte lysate (LAL) gel-clot test is a simple test for detection of endotoxin from Gram-negative bacteria. The test is based on a gel formation when a certain amount of endotoxin is present; it is a pass/fail test. The LAL test requires optimal pH, ionic strength, temperature, and time of incubation. Slight difference in these parameters may increase the frequency of false-positive responses. The aim of this paper is to evaluate how changes in the pH, temperature, and time of incubation affect the occurrence of false-positive responses in the LAL test. We find that slight differences in pH increase the frequency of false-positive responses 5-fold. Temperature and time of incubation affect the LAL test less. Simultaneous differences in these parameters significantly increase the frequency of false-positive responses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mordang, Jan-Jurre, E-mail: Jan-Jurre.Mordang@radboudumc.nl; Gubern-Mérida, Albert; Karssemeijer, Nico
Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performancemore » of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8–1.0 were significantly different between the system without BACs removal and the system with BACs removal, 0.129 ± 0.009 versus 0.144 ± 0.008 (p<0.05), respectively. Additionally, the sensitivity at one false positive per 50 cases and one false positive per 25 cases increased as well, 37% versus 51% (p<0.05) and 58% versus 67% (p<0.05) sensitivity, respectively. Additionally, the CADe system with BACs removal reduces the number of false positives per case by 29% on average. The same sensitivity at one false positive per 50 cases in the CADe system without BACs removal can be achieved at one false positive per 80 cases in the CADe system with BACs removal. Conclusions: By using dedicated algorithms to detect and remove breast arterial calcifications, the performance of CADe systems can be improved, in particular, at false positive rates representative for operating points used in screening.« less
Alegro, Maryana; Theofilas, Panagiotis; Nguy, Austin; Castruita, Patricia A.; Seeley, William; Heinsen, Helmut; Ushizima, Daniela M.
2017-01-01
Background Immunofluorescence (IF) plays a major role in quantifying protein expression in situ and understanding cell function. It is widely applied in assessing disease mechanisms and in drug discovery research. Automation of IF analysis can transform studies using experimental cell models. However, IF analysis of postmortem human tissue relies mostly on manual interaction, often subjected to low-throughput and prone to error, leading to low inter and intra-observer reproducibility. Human postmortem brain samples challenges neuroscientists because of the high level of autofluorescence caused by accumulation of lipofuscin pigment during aging, hindering systematic analyses. We propose a method for automating cell counting and classification in IF microscopy of human postmortem brains. Our algorithm speeds up the quantification task while improving reproducibility. New method Dictionary learning and sparse coding allow for constructing improved cell representations using IF images. These models are input for detection and segmentation methods. Classification occurs by means of color distances between cells and a learned set. Results Our method successfully detected and classified cells in 49 human brain images. We evaluated our results regarding true positive, false positive, false negative, precision, recall, false positive rate and F1 score metrics. We also measured user-experience and time saved compared to manual countings. Comparison with existing methods We compared our results to four open-access IF-based cell-counting tools available in the literature. Our method showed improved accuracy for all data samples. Conclusion The proposed method satisfactorily detects and classifies cells from human postmortem brain IF images, with potential to be generalized for applications in other counting tasks. PMID:28267565
Arthur, Terrance M; Bosilevac, Joseph M; Nou, Xiangwu; Koohmaraie, Mohammad
2005-08-01
Currently, several beef processors employ test-and-hold systems for increased quality control of ground beef. In such programs, each lot of product must be tested and found negative for Escherichia coli O157:H7 prior to release of the product into commerce. Optimization of three testing attributes (detection time, specificity, and sensitivity) is critical to the success of such strategies. Because ground beef is a highly perishable product, the testing methodology used must be as rapid as possible. The test also must have a low false-positive result rate so product is not needlessly discarded. False-negative results cannot be tolerated because they would allow contaminated product to be released and potentially cause disease. In this study, two culture-based and three PCR-based methods for detecting E. coli O157:H7 in ground beef were compared for their abilities to meet the above criteria. Ground beef samples were individually spiked with five genetically distinct strains of E. coli O157: H7 at concentrations of 17 and 1.7 CFU/65 g and then subjected to the various testing methodologies. There was no difference (P > 0.05) in the abilities of the PCR-based methods to detect E. coli O157:H7 inoculated in ground beef at 1.7 CFU/65 g. The culture-based systems detected more positive samples than did the PCR-based systems, but the detection times (21 to 48 h) were at least 9 h longer than those for the PCR-based methods (7.5 to 12 h). Ground beef samples were also spiked with potentially cross-reactive strains. The PCR-based systems that employed an immunomagnetic separation step prior to detection produced fewer false-positive results.
Transient ST segment depression during Holter monitoring: how to avoid false positive findings.
Völler, H; Andresen, D; Brüggemann, T; Jereczek, M; Becker, B; Schröder, R
1992-09-01
To increase the specificity of 24-hour Holter monitoring in detecting transient myocardial ischemia, we separated genuine ST deviations from those dependent on artifacts by adding a detailed shape analysis of real-time printouts to the usual criteria of significant ST segment depression. We screened 116 apparently healthy subjects; 31 had to be excluded, because of pathologic findings in preliminary examinations. The remaining 85 (49 women and 36 men; mean age, 43.1 years) underwent Holter monitoring for assessment of the extent, frequency, and duration of episodes of horizontal and descending ST segment depression of at least 0.1 mV that persisted for at least 60 msec after the J point and that were at least 1 minute apart. On the basis of these criteria, six subjects (7.1%) showed 24 episodes of horizontal or descending ST segment depression with a mean of 0.2 mV (range, 0.15 to 0.25 mV), a frequency of four episodes per 24 hours (one to nine), and a duration of 12.2 minutes (range 3-range 41 minutes). Supplementary criteria--e.g., sudden onset of ST segment depression, identical orientation of PQ and ST segments, or simultaneous increase in R and P wave amplitude--made it possible to identify ST changes caused by artifacts in four volunteers. In only two subjects (2.4%) could true silent ischemia not be differentiated from false positive results. Thus consideration of only the extent, frequency, and duration of episodes does not permit a differentiation between true silent ischemia and false positive results. A supplementary shape analysis increases the specificity of ST segment analysis in detecting transient myocardial ischemia during 24-hour Holter monitoring.
Gabriel, M; Muehllechner, P; Decristoforo, C; von Guggenberg, E; Kendler, D; Prommegger, R; Profanter, C; Moncayo, R; Virgolini, I
2005-09-01
To evaluate the use of 99mTc-EDDA-hydrazinonicotinyl-Tyr3-octreotide (Tc-TOC) for staging and follow-up of neuroendocrine gastro-entero-pancreatic (GEP) tumors with special focus on the acquisition protocol including single photon emission computed tomography (SPECT). Eighty-eight patients (37 female, 51 male; age range: 16 to 81 years; mean age: 56.3 years) were studied: 42 patients for staging after initial histological confirmation and 46 patients during post-therapy follow-up. An average activity of 400 MBq of the radiopharmaceutical was injected. All tumors originated from neuroendocrine tissue of the gastroenteropancreatic tract. Whole body scintigrams at 4 h postinjection and SPECT of the abdomen were obtained in all patients. Additional planar images of the abdomen were acquired at 2 h after injection in 68 patients. The Tc-TOC scan result was true-positive in 56 patients, true-negative in 17, false-negative in 14, and false-positive in 1 patient. The false-positive finding was caused by a colonic adenoma. Overall, a scan sensitivity of 80% (56/70 patients), specificity of 94.4% (17/18 patients) and accuracy of 82.9% (73/88 patients) were calculated on patient basis. In total, Tc-TOC detected 357 foci in 69 patients. In 7 patients equivocal findings were observed in the bowel at 4 h postinjection without corresponding tracer uptake in the scan 2 h earlier, meaning that these abnormal findings were correctly classified as non-malignant. In addition to planar views, SPECT revealed further 62 lesions. Tc-TOC with one-day, dual-time acquisition protocol is an accurate staging procedure in patients with neuroendocrine GEP tumors. SPECT shows high sensitivity for detection of abdominal lesions, while earlier images improve the reliability of abnormal abdominal findings.
DSM-5: proposed changes to depressive disorders.
Wakefield, Jerome C
2012-03-01
The Diagnostic and Statistical Manual of Mental Disorders (DSM) is currently undergoing a revision that will lead to a fifth edition in 2013. Proposed changes for DSM-5 include the creation of several new categories of depressive disorder. Some nosologists have expressed concern that the proposed changes could yield many 'false-positive diagnoses' in which normal distress is mislabeled as a mental disorder. Such confusion of normal distress and mental disorder undermines the interpretability of clinical trials and etiological research, causes inefficient allocation of resources, and incurs risks of unnecessary treatment. To evaluate these concerns, I critically examine five proposed DSM-5 expansions in the scope of depressive and grief disorders: (1) a new mixed anxiety/depression category; (2) a new premenstrual dysphoric disorder category; (3) elimination of the major depression bereavement exclusion; (4) elimination of the adjustment disorder bereavement exclusion, thus allowing the diagnosis of subsyndromal depressive symptoms during bereavement as adjustment disorders; and (5) a new category of adjustment disorder related to bereavement for diagnosing pathological non-depressive grief. I examine each proposal's face validity and conceptual coherence as well as empirical support where relevant, with special attention to potential implications for false-positive diagnoses. I conclude that mixed anxiety/depression and premenstrual dysphoric disorder are needed categories, but are too broadly drawn and will yield substantial false positives; that the elimination of the bereavement exclusion is not supported by the evidence; and that the proposed elimination of the adjustment-disorder bereavement exclusion, as well as the new category of grief-related adjustment disorder, are inconsistent with recent grief research, which suggests that these proposals would massively pathologize normal grief responses.
Dasgupta, Amitava; Wahed, Amer; Wells, Alice
2002-02-01
Several adulterants are used to mask tests for abused drugs in urine. Adulterants such as "Klear" and "Whizzies" contain potassium nitrite, and "Urine Luck" contains pyridinium chlorochromate (PCC). The presence of these adulterants cannot be detected by routine specimen integrity checks (pH, specific gravity, and temperature). We developed rapid spot tests for detecting these adulterants in urine. Addition of 3% hydrogen peroxide in urine adulterated with PCC caused rapid formation of a dark brown color. In contrast, unadulterated urine turned colorless when hydrogen peroxide was added. When urine contaminated with nitrite and 2 to 3 drops of 2N hydrochloric acid were added to 2% aqueous potassium permanganate solution, the dark pink permanganate solution turned colorless immediately with effervescence. Urine contaminated with nitrite liberated iodine from potassium iodide solution in the presence of 2N hydrochloric acid. Urine adulterated with PCC also liberated iodine from potassium iodide in acid medium but did not turn potassium permanganate solution colorless. Urine specimens from volunteers and random urine samples that tested negative for drugs did not cause false-positive results. These rapid spot tests are useful for detecting adulterated urine to avoid false-negative drug tests.
Terakado, Shingo; Ohmura, Naoya; Park, Seok-Un; Lee, Seung-Min; Glass, Thomas R
2013-01-01
Development and modifications are described that expand the application of an immunoassay from the detection of Kanechlors (Japanese technical PCBs mixtures) to the detection of Aroclors (U. S. technical PCB mixtures, used in Korea) in contaminated Korean transformer oil. The first necessary modification was the development of a new antibody with a reactivity profile favorable for Aroclors. The second modification was the addition of a second column to the solid-phase extraction method to reduce assay interference caused by the Korean oil matrix. The matrix interference is suspected to be caused by the presence of synthetic oils (or similar materials) present as contaminants. The modified assay was validated by comparison to high-resolution gas chromatography/high-resolution mass spectrometry analysis, and was shown to be tolerant of up to 10% of several common synthetic insulating oils. Finally the screening performance of the modified assay was evaluated using 500 used transformer oil samples of Korean origin, and was shown to have good performance in terms of false positive and false negative rates. This report provides evidence for the first establishment of immunoassay screening for Aroclor based PCB contamination in Korean transformer oil.
Identification student’s misconception of heat and temperature using three-tier diagnostic test
NASA Astrophysics Data System (ADS)
Suliyanah; Putri, H. N. P. A.; Rohmawati, L.
2018-03-01
The objective of this research is to develop a Three-Tier Diagnostic Test (TTDT) to identify the student's misconception of heat and temperature. Stages of development include: analysis, planning, design, development, evaluation and revise. The results of this study show that (1) the quality of the three-tier type diagnostic test instrument developed has been expressed well with the following details: (a) Internal validity of 88.19% belonging to the valid category. (b) External validity of empirical construct validity test using Pearson Product Moment obtained 0.43 is classified and result of empirical construct validity test obtained false positives 6.1% and false negatives 5.9% then the instrument was valid. (c) Test reliability by using Cronbach’s Alpha of 0.98 which means acceptable. (d) The 80% difficulty level test is quite difficult. (2) Student misconceptions on the temperature of heat and displacement materials based on the II test the highest (84%), the lowest (21%), and the non-misconceptions (7%). (3) The highest cause of misconception among students is associative thinking (22%) and the lowest is caused by incomplete or incomplete reasoning (11%). Three-Tier Diagnostic Test (TTDT) could identify the student's misconception of heat and temperature.
Bone marrow cells stained by azide-conjugated Alexa fluors in the absence of an alkyne label.
Lin, Guiting; Ning, Hongxiu; Banie, Lia; Qiu, Xuefeng; Zhang, Haiyang; Lue, Tom F; Lin, Ching-Shwun
2012-09-01
Thymidine analog 5-ethynyl-2'-deoxyuridine (EdU) has recently been introduced as an alternative to 5-bromo-2-deoxyuridine (BrdU) for cell labeling and tracking. Incorporation of EdU into replicating DNA can be detected by azide-conjugated fluors (eg, Alexa-azide) through a Cu(i)-catalyzed click reaction between EdU's alkyne moiety and azide. While this cell labeling method has proven to be valuable for tracking transplanted stem cells in various tissues, we have found that some bone marrow cells could be stained by Alexa-azide in the absence of EdU label. In intact rat femoral bone marrow, ~3% of nucleated cells were false-positively stained, and in isolated bone marrow cells, ~13%. In contrast to true-positive stains, which localize in the nucleus, the false-positive stains were cytoplasmic. Furthermore, while true-positive staining requires Cu(i), false-positive staining does not. Reducing the click reaction time or reducing the Alexa-azide concentration failed to improve the distinction between true- and false-positive staining. Hematopoietic and mesenchymal stem cell markers CD34 and Stro-1 did not co-localize with the false-positively stained cells, and these cells' identity remains unknown.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartholomew, Rachel A.; Ozanich, Richard M.; Arce, Jennifer S.
2017-02-01
The goal of this testing was to evaluate the ability of currently available commercial off-the-shelf (COTS) biological indicator tests and immunoassays to detect Bacillus anthracis (Ba) spores and ricin. In general, immunoassays provide more specific identification of biological threats as compared to indicator tests [3]. Many of these detection products are widely used by first responders and other end users. In most cases, performance data for these instruments are supplied directly from the manufacturer, but have not been verified by an external, independent assessment [1]. Our test plan modules included assessments of inclusivity (ability to generate true positive results), commonlymore » encountered hoax powders (which can cause potential interferences or false positives), and estimation of limit of detection (LOD) (sensitivity) testing.« less
Screening for Ovarian Cancer: US Preventive Services Task Force Recommendation Statement.
Grossman, David C; Curry, Susan J; Owens, Douglas K; Barry, Michael J; Davidson, Karina W; Doubeni, Chyke A; Epling, John W; Kemper, Alex R; Krist, Alex H; Kurth, Ann E; Landefeld, C Seth; Mangione, Carol M; Phipps, Maureen G; Silverstein, Michael; Simon, Melissa A; Tseng, Chien-Wen
2018-02-13
With approximately 14 000 deaths per year, ovarian cancer is the fifth most common cause of cancer death among US women and the leading cause of death from gynecologic cancer. More than 95% of ovarian cancer deaths occur among women 45 years and older. To update the 2012 US Preventive Services Task Force (USPSTF) recommendation on screening for ovarian cancer. The USPSTF reviewed the evidence on the benefits and harms of screening for ovarian cancer in asymptomatic women not known to be at high risk for ovarian cancer (ie, high risk includes women with certain hereditary cancer syndromes that increase their risk for ovarian cancer). Outcomes of interest included ovarian cancer mortality, quality of life, false-positive rate, surgery and surgical complication rates, and psychological effects of screening. The USPSTF found adequate evidence that screening for ovarian cancer does not reduce ovarian cancer mortality. The USPSTF found adequate evidence that the harms from screening for ovarian cancer are at least moderate and may be substantial in some cases, and include unnecessary surgery for women who do not have cancer. Given the lack of mortality benefit of screening, and the moderate to substantial harms that could result from false-positive screening test results and subsequent surgery, the USPSTF concludes with moderate certainty that the harms of screening for ovarian cancer outweigh the benefit, and the net balance of the benefit and harms of screening is negative. The USPSTF recommends against screening for ovarian cancer in asymptomatic women. (D recommendation) This recommendation applies to asymptomatic women who are not known to have a high-risk hereditary cancer syndrome.
Chidambaram, Meenachi; Parija, Subhash Chandra; Toi, Pampa Ch; Mandal, Jharna; Sankaramoorthy, Dhanalakshmi; George, Santosh; Natarajan, Mailan; Padukone, Shashiraja
2017-01-01
Human hookworm infection is caused mainly by Necator americanus and Ancylostoma duodenale . Among the zoonotic hookworm species, only Ancylostoma ceylanicum causes potent human infections where dogs and cats act as reservoir of infection. Hence, species differentiation is imperative because the eradication of both anthroponotic and zoonotic hookworm depends on the concurrent human and animal health programs, hygienic practices, and mass drug administration for humans and dogs. This study was performed to evaluate the utility of polymerase chain reaction (PCR) for detection of hookworm infections. A total of 209 stool samples were collected and subjected to stool microscopy, Kato-Katz method to identify the intensity of the infection, coproculture for L3 larval identification and species differentiation and semi-nested PCR with sequencing. The prevalence of hookworm was estimated as 7.6%. Highest hookworm prevalence was seen in 20-30 years of age group. Majority of the infections were mild intensity infections. Sensitivity of stool microscopy was found to be 81.2% and the specificity was 100%. Sensitivity of Kato-Katz method was 87.5% and specificity was 100%. True positivity by agar plate culture was 83.3% and false positivity rate was 16.6%. Stool microscopy is the major mode of detection, but it has a higher false negative rate. Coproculture is time-consuming and needs the expertise to differentiate the species. On the other hand, PCR is known to be a sensitive, specific, and a reliable investigative tool which can help in diagnosis as well as in species differentiation.
The Illusion of the Positive: The impact of natural and induced mood on older adults’ false recall
Emery, Lisa; Hess, Thomas M.; Elliot, Tonya
2012-01-01
Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults’ information processing and potentially increase underlying cognitive age differences. PMID:22292431
The illusion of the positive: the impact of natural and induced mood on older adults' false recall.
Emery, Lisa; Hess, Thomas M; Elliot, Tonya
2012-11-01
Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995 , Journal of Experimental Psychology: Learning, Memory, and Cognition, 21, 803) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults' information processing and potentially increase underlying cognitive age differences.
Alonso, Roberto; Pérez-García, Felipe; Gijón, Paloma; Collazos, Ana; Bouza, Emilio
2018-06-01
The Architect HIV Ag/Ab Combo Assay, a fourth-generation ELISA, has proven to be highly reliable for the diagnosis of HIV infection. However, its high sensitivity may lead to false-positive results. To evaluate the diagnostic performance of Architect in a low-prevalence population and to assess the role of the sample-to-cutoff ratio (S/CO) in reducing the frequency of false-positive results. We conducted a retrospective study of samples analyzed by Architect between January 2015 and June 2017. Positive samples were confirmed by immunoblot (RIBA) or nucleic acid amplification tests (NAATs). Different S/CO thresholds (1, 2.5, 10, 25, and 100) were analyzed to determine sensitivity, specificity, and negative and positive predictive values (NPV, PPV). ROC analysis was used to determine the optimal S/CO. A total of 69,471 samples were analyzed. 709 (1.02%) were positive by Architect. Of these, 63 (8.89%) were false-positive results. Most of them (93.65%) were in samples with S/CO < 100. However, most confirmations by NAATs (12 out of 19 cases) were also recorded for these samples. The optimal S/CO was 2.5, which provided the highest area under the ROC curve (0.9998) and no false-negative results. With this S/CO, sensitivity and specificity were 100.0%, and PPV and NPV were 95.8% and 100.0%, respectively. In addition, the frequency of false-positive results decreased significantly to 4.15%. Although Architect generates a relatively high number of false-positive results, raising the S/CO limit too much to increase specificity can lead to false-negative results, especially in newly infected individuals. Copyright © 2018 Elsevier B.V. All rights reserved.
Coffey, Christanne; Serra, John; Goebel, Mat; Espinoza, Sarah; Castillo, Edward; Dunford, James
2018-05-03
A significant increase in false positive ST-elevation myocardial infarction (STEMI) electrocardiogram interpretations was noted after replacement of all of the City of San Diego's 110 monitor-defibrillator units with a new brand. These concerns were brought to the manufacturer and a revised interpretive algorithm was implemented. This study evaluated the effects of a revised interpretation algorithm to identify STEMI when used by San Diego paramedics. Data were reviewed 6 months before and 6 months after the introduction of a revised interpretation algorithm. True-positive and false-positive interpretations were identified. Factors contributing to an incorrect interpretation were assessed and patient demographics were collected. A total of 372 (234 preimplementation, 138 postimplementation) cases met inclusion criteria. There was a significant reduction in false positive STEMI (150 preimplementation, 40 postimplementation; p < 0.001) after implementation. The most common factors resulting in false positive before implementation were right bundle branch block, left bundle branch block, and atrial fibrillation. The new algorithm corrected for these misinterpretations with most postimplementation false positives attributed to benign early repolarization and poor data quality. Subsequent follow-up at 10 months showed maintenance of the observed reduction in false positives. This study shows that introducing a revised 12-lead interpretive algorithm resulted in a significant reduction in the number of false positive STEMI electrocardiogram interpretations in a large urban emergency medical services system. Rigorous testing and standardization of new interpretative software is recommended before introduction into a clinical setting to prevent issues resulting from inappropriate cardiac catheterization laboratory activations. Copyright © 2018 Elsevier Inc. All rights reserved.
True detection limits in an experimental linearly heteroscedastic system.. Part 2
NASA Astrophysics Data System (ADS)
Voigtman, Edward; Abraham, Kevin T.
2011-11-01
Despite much different processing of the experimental fluorescence detection data presented in Part 1, essentially the same estimates were obtained for the true theoretical Currie decision levels ( YC and XC) and true Currie detection limits ( YD and XD). The obtained experimental values, for 5% probability of false positives and 5% probability of false negatives, were YC = 56.0 mV, YD = 125. mV, XC = 0.132 μg/mL and XD = 0.293 μg/mL. For 5% probability of false positives and 1% probability of false negatives, the obtained detection limits were YD = 158 . mV and XD = 0.371 μg/mL. Furthermore, by using bootstrapping methodology on the experimental data for the standards and the analytical blank, it was possible to validate previously published experimental domain expressions for the decision levels ( yC and xC) and detection limits ( yD and xD). This was demonstrated by testing the generated decision levels and detection limits for their performance in regard to false positives and false negatives. In every case, the obtained numbers of false negatives and false positives were as specified a priori.
Janzen, Nils; Sander, Stefanie; Terhardt, Michael; Steuerwald, Ulrike; Peter, Michael; Das, Anibh M; Sander, Johannes
2011-12-11
Newborn screening for congenital adrenal hyperplasia (CAH) is usually done by quantifying 17α-hydroxyprogesterone using immunoassay. However, this test produces high rates of false positive results caused by cross reacting steroids. Therefore we have developed a selective and specific method with a short run time (1.25 min) for quantification of 17α-hydroxyprogesterone, 21-deoxycortisol, 11-deoxycortisol, 11-deoxycorticosterone and cortisol from dried blood spots. The extraction procedure is very simple and steroid separation is ensured on a BEH C18 column and an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Analysis was done in positive ionization mode (ESI+) and recorded in multiple reaction monitoring mode (MRM). The method gave linear results for all steroids over a range of 5-200 (cortisol: 12.5-500)nmol/L with coefficients of regression >0.992. Absolute recovery was >64.1%. Across the analytical range the inter-assay coefficient of variation (CV) was <3%. Newborn blood samples of patients with confirmed 21-CAH and 11-CAH could clearly be distinguished from samples of unaffected newborns falsely positive on immunoassay. The method is not influenced by cross reactions as found on immunoassay. Analysis of dried blood spots shows that this method is sensitive and fast enough to allow rapid analysis and can therefore improve the newborn screening program. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lee, Haeil; Lee, Hansang; Park, Minseok; Kim, Junmo
2017-03-01
Lung cancer is the most common cause of cancer-related death. To diagnose lung cancers in early stages, numerous studies and approaches have been developed for cancer screening with computed tomography (CT) imaging. In recent years, convolutional neural networks (CNN) have become one of the most common and reliable techniques in computer aided detection (CADe) and diagnosis (CADx) by achieving state-of-the-art-level performances for various tasks. In this study, we propose a CNN classification system for false positive reduction of initially detected lung nodule candidates. First, image patches of lung nodule candidates are extracted from CT scans to train a CNN classifier. To reflect the volumetric contextual information of lung nodules to 2D image patch, we propose a weighted average image patch (WAIP) generation by averaging multiple slice images of lung nodule candidates. Moreover, to emphasize central slices of lung nodules, slice images are locally weighted according to Gaussian distribution and averaged to generate the 2D WAIP. With these extracted patches, 2D CNN is trained to achieve the classification of WAIPs of lung nodule candidates into positive and negative labels. We used LUNA 2016 public challenge database to validate the performance of our approach for false positive reduction in lung CT nodule classification. Experiments show our approach improves the classification accuracy of lung nodules compared to the baseline 2D CNN with patches from single slice image.
An automated real-time microscopy system for analysis of fluorescence resonance energy transfer
NASA Astrophysics Data System (ADS)
Bernardini, André; Wotzlaw, Christoph; Lipinski, Hans-Gerd; Fandrey, Joachim
2010-05-01
Molecular imaging based on Fluorescence Resonance Energy Transfer (FRET) is widely used in cellular physiology both for protein-protein interaction analysis and detecting conformational changes of single proteins, e.g. during activation of signaling cascades. However, getting reliable results from FRET measurements is still hampered by methodological problems such as spectral bleed through, chromatic aberration, focal plane shifts and false positive FRET. Particularly false positive FRET signals caused by random interaction of the fluorescent dyes can easily lead to misinterpretation of the data. This work introduces a Nipkow Disc based FRET microscopy system, that is easy to operate without expert knowledge of FRET. The system automatically accounts for all relevant sources of errors and provides various result presentations of two, three and four dimensional FRET data. Two examples are given to demonstrate the scope of application. An interaction analysis of the two subunits of the hypoxia-inducible transcription factor 1 demonstrates the use of the system as a tool for protein-protein interaction analysis. As an example for time lapse observations, the conformational change of the fluorophore labeled heat shock protein 33 in the presence of oxidant stress is shown.
Kunakorn, M; Raksakai, K; Pracharktam, R; Sattaudom, C
1999-03-01
Our experiences from 1993 to 1997 in the development and use of IS6110 base PCR for the diagnosis of extrapulmonary tuberculosis in a routine clinical setting revealed that error-correcting processes can improve existing diagnostic methodology. The reamplification method initially used had a sensitivity of 90.91% and a specificity of 93.75%. The concern was focused on the false positive results of this method caused by product-carryover contamination. This method was changed to single round PCR with carryover prevention by uracil DNA glycosylase (UDG), resulting in a 100% specificity but only 63% sensitivity. Dot blot hybridization was added after the single round PCR, increasing the sensitivity to 87.50%. However, false positivity resulted from the nonspecific dot blot hybridization signal, reducing the specificity to 89.47%. The hybridization of PCR was changed to a Southern blot with a new oligonucleotide probe giving the sensitivity of 85.71% and raising the specificity to 99.52%. We conclude that the PCR protocol for routine clinical use should include UDG for carryover prevention and hybridization with specific probes to optimize diagnostic sensitivity and specificity in extrapulmonary tuberculosis testing.
Detection of Spoofed MAC Addresses in 802.11 Wireless Networks
NASA Astrophysics Data System (ADS)
Tao, Kai; Li, Jing; Sampalli, Srinivas
Medium Access Control (MAC) address spoofing is considered as an important first step in a hacker's attempt to launch a variety of attacks on 802.11 wireless networks. Unfortunately, MAC address spoofing is hard to detect. Most current spoofing detection systems mainly use the sequence number (SN) tracking technique, which has drawbacks. Firstly, it may lead to an increase in the number of false positives. Secondly, such techniques cannot be used in systems with wireless cards that do not follow standard 802.11 sequence number patterns. Thirdly, attackers can forge sequence numbers, thereby causing the attacks to go undetected. We present a new architecture called WISE GUARD (Wireless Security Guard) for detection of MAC address spoofing on 802.11 wireless LANs. It integrates three detection techniques - SN tracking, Operating System (OS) fingerprinting & tracking and Received Signal Strength (RSS) fingerprinting & tracking. It also includes the fingerprinting of Access Point (AP) parameters as an extension to the OS fingerprinting for detection of AP address spoofing. We have implemented WISE GUARD on a test bed using off-the-shelf wireless devices and open source drivers. Experimental results show that the new design enhances the detection effectiveness and reduces the number of false positives in comparison with current approaches.
Hofvind, Solveig; Sagstad, Silje; Sebuødegård, Sofie; Chen, Ying; Roman, Marta; Lee, Christoph I
2018-04-01
Purpose To compare rates and tumor characteristics of interval breast cancers (IBCs) detected after a negative versus false-positive screening among women participating in the Norwegian Breast Cancer Screening Program. Materials and Methods The Cancer Registry Regulation approved this retrospective study. Information about 423 445 women aged 49-71 years who underwent 789 481 full-field digital mammographic screening examinations during 2004-2012 was extracted from the Cancer Registry of Norway. Rates and odds ratios of IBC among women with a negative (the reference group) versus a false-positive screening were estimated by using logistic regression models adjusted for age at diagnosis and county of residence. Results A total of 1302 IBCs were diagnosed after 789 481 screening examinations, of which 7.0% (91 of 1302) were detected among women with a false-positive screening as the most recent breast imaging examination before detection. By using negative screening as the reference, adjusted odds ratios of IBCs were 3.3 (95% confidence interval [CI]: 2.6, 4.2) and 2.8 (95% CI: 1.8, 4.4) for women with a false-positive screening without and with needle biopsy, respectively. Women with a previous negative screening had a significantly lower proportion of tumors that were 10 mm or less (14.3% [150 of 1049] vs 50.0% [seven of 14], respectively; P < .01) and grade I tumors (13.2% [147 of 1114] vs 42.9% [six of 14]; P < .01), but a higher proportion of cases with lymph nodes positive for cancer (40.9% [442 of 1080] vs 13.3% [two of 15], respectively; P = .03) compared with women with a previous false-positive screening with benign biopsy. A retrospective review of the screening mammographic examinations identified 42.9% (39 of 91) of the false-positive cases to be the same lesion as the IBC. Conclusion By using a negative screening as the reference, a false-positive screening examination increased the risk of an IBC three-fold. The tumor characteristics of IBC after a negative screening were less favorable compared with those detected after a previous false-positive screening. © RSNA, 2017 Online supplemental material is available for this article.
Designing occupancy studies when false-positive detections occur
Clement, Matthew
2016-01-01
1.Recently, estimators have been developed to estimate occupancy probabilities when false-positive detections occur during presence-absence surveys. Some of these estimators combine different types of survey data to improve estimates of occupancy. With these estimators, there is a tradeoff between the number of sample units surveyed, and the number and type of surveys at each sample unit. Guidance on efficient design of studies when false positives occur is unavailable. 2.For a range of scenarios, I identified survey designs that minimized the mean square error of the estimate of occupancy. I considered an approach that uses one survey method and two observation states and an approach that uses two survey methods. For each approach, I used numerical methods to identify optimal survey designs when model assumptions were met and parameter values were correctly anticipated, when parameter values were not correctly anticipated, and when the assumption of no unmodelled detection heterogeneity was violated. 3.Under the approach with two observation states, false positive detections increased the number of recommended surveys, relative to standard occupancy models. If parameter values could not be anticipated, pessimism about detection probabilities avoided poor designs. Detection heterogeneity could require more or fewer repeat surveys, depending on parameter values. If model assumptions were met, the approach with two survey methods was inefficient. However, with poor anticipation of parameter values, with detection heterogeneity, or with removal sampling schemes, combining two survey methods could improve estimates of occupancy. 4.Ignoring false positives can yield biased parameter estimates, yet false positives greatly complicate the design of occupancy studies. Specific guidance for major types of false-positive occupancy models, and for two assumption violations common in field data, can conserve survey resources. This guidance can be used to design efficient monitoring programs and studies of species occurrence, species distribution, or habitat selection, when false positives occur during surveys.
A statistical model of false negative and false positive detection of phase singularities.
Jacquemet, Vincent
2017-10-01
The complexity of cardiac fibrillation dynamics can be assessed by analyzing the distribution of phase singularities (PSs) observed using mapping systems. Interelectrode distance, however, limits the accuracy of PS detection. To investigate in a theoretical framework the PS false negative and false positive rates in relation to the characteristics of the mapping system and fibrillation dynamics, we propose a statistical model of phase maps with controllable number and locations of PSs. In this model, phase maps are generated from randomly distributed PSs with physiologically-plausible directions of rotation. Noise and distortion of the phase are added. PSs are detected using topological charge contour integrals on regular grids of varying resolutions. Over 100 × 10 6 realizations of the random field process are used to estimate average false negative and false positive rates using a Monte-Carlo approach. The false detection rates are shown to depend on the average distance between neighboring PSs expressed in units of interelectrode distance, following approximately a power law with exponents in the range of 1.14 to 2 for false negatives and around 2.8 for false positives. In the presence of noise or distortion of phase, false detection rates at high resolution tend to a non-zero noise-dependent lower bound. This model provides an easy-to-implement tool for benchmarking PS detection algorithms over a broad range of configurations with multiple PSs.
Clinical decision support alert malfunctions: analysis and empirically derived taxonomy.
Wright, Adam; Ai, Angela; Ash, Joan; Wiesen, Jane F; Hickman, Thu-Trang T; Aaron, Skye; McEvoy, Dustin; Borkowsky, Shane; Dissanayake, Pavithra I; Embi, Peter; Galanter, William; Harper, Jeremy; Kassakian, Steve Z; Ramoni, Rachel; Schreiber, Richard; Sirajuddin, Anwar; Bates, David W; Sittig, Dean F
2018-05-01
To develop an empirically derived taxonomy of clinical decision support (CDS) alert malfunctions. We identified CDS alert malfunctions using a mix of qualitative and quantitative methods: (1) site visits with interviews of chief medical informatics officers, CDS developers, clinical leaders, and CDS end users; (2) surveys of chief medical informatics officers; (3) analysis of CDS firing rates; and (4) analysis of CDS overrides. We used a multi-round, manual, iterative card sort to develop a multi-axial, empirically derived taxonomy of CDS malfunctions. We analyzed 68 CDS alert malfunction cases from 14 sites across the United States with diverse electronic health record systems. Four primary axes emerged: the cause of the malfunction, its mode of discovery, when it began, and how it affected rule firing. Build errors, conceptualization errors, and the introduction of new concepts or terms were the most frequent causes. User reports were the predominant mode of discovery. Many malfunctions within our database caused rules to fire for patients for whom they should not have (false positives), but the reverse (false negatives) was also common. Across organizations and electronic health record systems, similar malfunction patterns recurred. Challenges included updates to code sets and values, software issues at the time of system upgrades, difficulties with migration of CDS content between computing environments, and the challenge of correctly conceptualizing and building CDS. CDS alert malfunctions are frequent. The empirically derived taxonomy formalizes the common recurring issues that cause these malfunctions, helping CDS developers anticipate and prevent CDS malfunctions before they occur or detect and resolve them expediently.
Pitfalls of national routine death statistics for maternal mortality study.
Saucedo, Monica; Bouvier-Colle, Marie-Hélène; Chantry, Anne A; Lamarche-Vadel, Agathe; Rey, Grégoire; Deneux-Tharaux, Catherine
2014-11-01
The lessons learned from the study of maternal deaths depend on the accuracy of data. Our objective was to assess time trends in the underestimation of maternal mortality (MM) in the national routine death statistics in France and to evaluate their current accuracy for the selection and causes of maternal deaths. National data obtained by enhanced methods in 1989, 1999, and 2007-09 were used as the gold standard to assess time trends in the underestimation of MM ratios (MMRs) in death statistics. Enhanced data and death statistics for 2007-09 were further compared by characterising false negatives (FNs) and false positives (FPs). The distribution of cause-specific MMRs, as assessed by each system, was described. Underestimation of MM in death statistics decreased from 55.6% in 1989 to 11.4% in 2007-09 (P < 0.001). In 2007-09, of 787 pregnancy-associated deaths, 254 were classified as maternal by the enhanced system and 211 by the death statistics; 34% of maternal deaths in the enhanced system were FNs in the death statistics, and 20% of maternal deaths in the death statistics were FPs. The hierarchy of causes of MM differed between the two systems. The discordances were mainly explained by the lack of precision in the drafting of death certificates by clinicians. Although the underestimation of MM in routine death statistics has decreased substantially over time, one third of maternal deaths remain unidentified, and the main causes of death are incorrectly identified in these data. Defining relevant priorities in maternal health requires the use of enhanced methods for MM study. © 2014 John Wiley & Sons Ltd.
Reconstruction based finger-knuckle-print verification with score level adaptive binary fusion.
Gao, Guangwei; Zhang, Lei; Yang, Jian; Zhang, Lin; Zhang, David
2013-12-01
Recently, a new biometrics identifier, namely finger knuckle print (FKP), has been proposed for personal authentication with very interesting results. One of the advantages of FKP verification lies in its user friendliness in data collection. However, the user flexibility in positioning fingers also leads to a certain degree of pose variations in the collected query FKP images. The widely used Gabor filtering based competitive coding scheme is sensitive to such variations, resulting in many false rejections. We propose to alleviate this problem by reconstructing the query sample with a dictionary learned from the template samples in the gallery set. The reconstructed FKP image can reduce much the enlarged matching distance caused by finger pose variations; however, both the intra-class and inter-class distances will be reduced. We then propose a score level adaptive binary fusion rule to adaptively fuse the matching distances before and after reconstruction, aiming to reduce the false rejections without increasing much the false acceptances. Experimental results on the benchmark PolyU FKP database show that the proposed method significantly improves the FKP verification accuracy.
De Carolis, S; Santucci, S; Botta, A; Garofalo, S; Martino, C; Perrelli, A; Salvi, S; Degennaro, Va; de Belvis, Ag; Ferrazzani, S; Scambia, G
2010-06-01
Our aims were to assess the frequency of false-positive IgM antibodies for cytomegalovirus in pregnant women with autoimmune diseases and in healthy women (controls) and to determine their relationship with pregnancy outcome. Data from 133 pregnancies in 118 patients with autoimmune diseases and from 222 pregnancies in 198 controls were assessed. When positive IgM for cytomegalovirus was detected, IgG avidity, cytomegalovirus isolation and polymerase chain reaction for CMV-DNA in maternal urine and amniotic fluid samples were performed in order to identify primary infection or false positivity. A statistically significantly higher rate of false-positive IgM was found in pregnancies with autoimmune diseases (16.5%) in comparison with controls (0.9%). A worse pregnancy outcome was observed among patients with autoimmune disease and false cytomegalovirus IgM in comparison with those without false positivity: earlier week of delivery (p = 0.017), lower neonatal birth weight (p = 0.0004) and neonatal birth weight percentile (p = 0.002), higher rate of intrauterine growth restriction (p = 0.02) and babies weighing less than 2000 g (p = 0.025) were encountered. The presence of false cytomegalovirus IgM in patients with autoimmune diseases could be used as a novel prognostic index of poor pregnancy outcome: it may reflect a non-specific activation of the immune system that could negatively affect pregnancy outcome. Lupus (2010) 19, 844-849.
Zhu, Li-Wei; Yang, Xue-Mei; Xu, Xiao-Qin; Xu, Jian; Lu, Huang-Jun; Yan, Li-Xing
2008-10-01
This study was aimed to analyze the results of false positive reaction in bacterial detection of blood samples with BacT/ALERT 3D system, to evaluate the specificity of this system, and to decrease the false positive reaction. Each reaction flasks in past five years were processed for bacteria isolation and identification. When the initial cultures were positive, the remaining samples and the corresponding units were recultured if still available. 11395 blood samples were detected. It is worthy of note that the incubator temperature should be stabilized, avoiding fluctuation; when the cultures were alarmed, the reaction flasks showed be kept some hours for further incubation so as to trace a sharply increasing signal to support the judgement of true bacterial growth. The results indicated that 122 samples (1.07%) wee positive at initial culture, out of them 107 samples (88.7%) were found bacterial, and 15 samples (12.3%) were found nothing. The detection curves of positive samples resulted from bacterial growth showed ascent. In conclusion, maintenance of temperature stability and avoidance of temperature fluctuation in incubator could decrease the occurrence of false-positive reaction in detection process. The reaction flasks with positive results at initial culture should be recultured, and whether existence of a sharply ascending logarilhimic growth phase in bacterial growth curve should be further detected, which are helpful to distinguish false-positive reactions from true positive, and thus increase the specificity of the BacT/ALERT system.
A comparison of acoustic montoring methods for common anurans of the northeastern United States
Brauer, Corinne; Donovan, Therese; Mickey, Ruth M.; Katz, Jonathan; Mitchell, Brian R.
2016-01-01
Many anuran monitoring programs now include autonomous recording units (ARUs). These devices collect audio data for extended periods of time with little maintenance and at sites where traditional call surveys might be difficult. Additionally, computer software programs have grown increasingly accurate at automatically identifying the calls of species. However, increased automation may cause increased error. We collected 435 min of audio data with 2 types of ARUs at 10 wetland sites in Vermont and New York, USA, from 1 May to 1 July 2010. For each minute, we determined presence or absence of 4 anuran species (Hyla versicolor, Pseudacris crucifer, Anaxyrus americanus, and Lithobates clamitans) using 1) traditional human identification versus 2) computer-mediated identification with software package, Song Scope® (Wildlife Acoustics, Concord, MA). Detections were compared with a data set consisting of verified calls in order to quantify false positive, false negative, true positive, and true negative rates. Multinomial logistic regression analysis revealed a strong (P < 0.001) 3-way interaction between the ARU recorder type, identification method, and focal species, as well as a trend in the main effect of rain (P = 0.059). Overall, human surveyors had the lowest total error rate (<2%) compared with 18–31% total errors with automated methods. Total error rates varied by species, ranging from 4% for A. americanus to 26% for L. clamitans. The presence of rain may reduce false negative rates. For survey minutes where anurans were known to be calling, the odds of a false negative were increased when fewer individuals of the same species were calling.
Bae, Y J; Jeon, Y J; Choi, B S; Koo, J-W; Song, J-J
2017-06-01
Typewriter tinnitus, a symptom characterized by paroxysmal attacks of staccato sounds, has been thought to be caused by neurovascular compression of the cochlear nerve, but the correlation between radiologic evidence of neurovascular compression of the cochlear nerve and symptom presentation has not been thoroughly investigated. The purpose of this study was to examine whether radiologic evidence of neurovascular compression of the cochlear nerve is pathognomonic in typewriter tinnitus. Fifteen carbamazepine-responding patients with typewriter tinnitus and 8 control subjects were evaluated with a 3D T2-weighted volume isotropic turbo spin-echo acquisition sequence. Groups 1 (16 symptomatic sides), 2 (14 asymptomatic sides), and 3 (16 control sides) were compared with regard to the anatomic relation between the vascular loop and the internal auditory canal and the presence of neurovascular compression of the cochlear nerve with/without angulation/indentation. The anatomic location of the vascular loop was not significantly different among the 3 groups (all, P > .05). Meanwhile, neurovascular compression of the cochlear nerve on MR imaging was significantly higher in group 1 than in group 3 ( P = .032). However, considerable false-positive (no symptoms with neurovascular compression of the cochlear nerve on MR imaging) and false-negative (typewriter tinnitus without demonstrable neurovascular compression of the cochlear nerve) findings were also observed. Neurovascular compression of the cochlear nerve was more frequently detected on the symptomatic side of patients with typewriter tinnitus compared with the asymptomatic side of these patients or on both sides of control subjects on MR imaging. However, considering false-positive and false-negative findings, meticulous history-taking and the response to the initial carbamazepine trial should be regarded as more reliable diagnostic clues than radiologic evidence of neurovascular compression of the cochlear nerve. © 2017 by American Journal of Neuroradiology.
Collins, Jeffrey M; Hunter, Mary; Gordon, Wanda; Kempker, Russell R; Blumberg, Henry M; Ray, Susan M
2018-06-01
Following large declines in tuberculosis transmission the United States, large-scale screening programs targeting low-risk healthcare workers are increasingly a source of false-positive results. We report a large cluster of presumed false-positive tuberculin skin test results in healthcare workers following a change to 50-dose vials of Tubersol tuberculin.Infect Control Hosp Epidemiol 2018;39:750-752.
Rare earth elements (REE) and certain alkaline earths can produce M+2 interferences in ICP-MS because they have sufficiently low second ionization energies. Four REEs (150Sm, 150Nd, 156Gd and 156Dy) produce false positives on 75As and 78Se and 132Ba can produce a false positive ...
Algorithm of reducing the false positives in IDS based on correlation Analysis
NASA Astrophysics Data System (ADS)
Liu, Jianyi; Li, Sida; Zhang, Ru
2018-03-01
This paper proposes an algorithm of reducing the false positives in IDS based on correlation Analysis. Firstly, the algorithm analyzes the distinguishing characteristics of false positives and real alarms, and preliminary screen the false positives; then use the method of attribute similarity clustering to the alarms and further reduces the amount of alarms; finally, according to the characteristics of multi-step attack, associated it by the causal relationship. The paper also proposed a reverse causation algorithm based on the attack association method proposed by the predecessors, turning alarm information into a complete attack path. Experiments show that the algorithm simplifies the number of alarms, improve the efficiency of alarm processing, and contribute to attack purposes identification and alarm accuracy improvement.
NASA Astrophysics Data System (ADS)
Devipriya, K.; Ivy, B. Persis Urbana; Prabha, D.
2018-04-01
A mobile ad hoc network (MANET) is an assemblage of nodes composed of mobile devices coupled in various ways wirelessly which do not have any central administration. Each node in MANET cooperates in forwarding packets in the network. This type of collaboration incurs high cost but there exits nodes that declines to cooperate leading to selfish conduct of nodes which effects overall network performance. To discover the attacks caused by such nodes, a renowned mechanism using watchdog can be deployed. In infrastructure less network attack detection and reaction and high false positives, false negatives initiating black hole attack becomes major issue in watchdog. This paper put forward a collaborative approach for identifying such attacks in MANET. Through abstract analysis and extensive simulation of this approach, the detection time of misbehaved nodes is reduced and substantial enhancement in overhead and throughput is witnessed.
Diagnosis of Fanconi Anemia by Diepoxybutane Analysis
Auerbach, Arleen D.
2015-01-01
Fanconi anemia (FA) is a genetically and phenotypically heterogeneous disorder characterized by congenital malformations, progressive bone marrow failure, and predisposition to cancer, particularly hematological malignancies and solid tumors of the head and neck. The main role of FA proteins is in the repair of DNA interstrand crosslinks (ICLs). FA results from pathogenic variants in at least 16 distinct genes, causing genomic instability. Although the highly variable phenotype makes accurate diagnosis on the basis of clinical manifestations difficult in some patients, diagnosis based on a profound sensitivity to DNA crosslinking agents can be used to identify the pre-anemia patient as well as patients with aplastic anemia or leukemia who may or may not have the physical stigmata associated with the syndrome. Diepoxybutane (DEB) analysis is the preferred test for FA because other agents have higher rates of false-positive and false-negative results. PMID:25827349
Rapid analytical methods for on-site triage for traumatic brain injury.
North, Stella H; Shriver-Lake, Lisa C; Taitt, Chris R; Ligler, Frances S
2012-01-01
Traumatic brain injury (TBI) results from an event that causes rapid acceleration and deceleration of the brain or penetration of the skull with an object. Responses to stimuli and questions, loss of consciousness, and altered behavior are symptoms currently used to justify brain imaging for diagnosis and therapeutic guidance. Tests based on such symptoms are susceptible to false-positive and false-negative results due to stress, fatigue, and medications. Biochemical markers of neuronal damage and the physiological response to that damage are being identified. Biosensors capable of rapid measurement of such markers in the circulation offer a solution for on-site triage, as long as three criteria are met: (a) Recognition reagents can be identified that are sufficiently sensitive and specific, (b) the biosensor can provide quantitative assessment of multiple markers rapidly and simultaneously, and (c) both the sensor and reagents are designed for use outside the laboratory.
Do the benefits outweigh the side effects of colorectal cancer surveillance? A systematic review.
Augestad, Knut Magne; Rose, Johnie; Crawshaw, Benjamin; Cooper, Gregory; Delaney, Conor
2014-05-15
Most patients treated with curative intent for colorectal cancer (CRC) are included in a follow-up program involving periodic evaluations. The survival benefits of a follow-up program are well delineated, and previous meta-analyses have suggested an overall survival improvement of 5%-10% by intensive follow-up. However, in a recent randomized trial, there was no survival benefit when a minimal vs an intensive follow-up program was compared. Less is known about the potential side effects of follow-up. Well-known side effects of preventive programs are those of somatic complications caused by testing, negative psychological consequences of follow-up itself, and the downstream impact of false positive or false negative tests. Accordingly, the potential survival benefits of CRC follow-up must be weighed against these potential negatives. The present review compares the benefits and side effects of CRC follow-up, and we propose future areas for research.
Rapid Analytical Methods for On-Site Triage for Traumatic Brain Injury
NASA Astrophysics Data System (ADS)
North, Stella H.; Shriver-Lake, Lisa C.; Taitt, Chris R.; Ligler, Frances S.
2012-07-01
Traumatic brain injury (TBI) results from an event that causes rapid acceleration and deceleration of the brain or penetration of the skull with an object. Responses to stimuli and questions, loss of consciousness, and altered behavior are symptoms currently used to justify brain imaging for diagnosis and therapeutic guidance. Tests based on such symptoms are susceptible to false-positive and false-negative results due to stress, fatigue, and medications. Biochemical markers of neuronal damage and the physiological response to that damage are being identified. Biosensors capable of rapid measurement of such markers in the circulation offer a solution for on-site triage, as long as three criteria are met: (a) Recognition reagents can be identified that are sufficiently sensitive and specific, (b) the biosensor can provide quantitative assessment of multiple markers rapidly and simultaneously, and (c) both the sensor and reagents are designed for use outside the laboratory.
Finding 'Evidence of Absence' in Medical Notes: Using NLP for Clinical Inferencing.
Carter, Marjorie E; Divita, Guy; Redd, Andrew; Rubin, Michael A; Samore, Matthew H; Gupta, Kalpana; Trautner, Barbara W; Gundlapalli, Adi V
2016-01-01
Extracting evidence of the absence of a target of interest from medical text can be useful in clinical inferencing. The purpose of our study was to develop a natural language processing (NLP) pipelineto identify the presence of indwelling urinary catheters from electronic medical notes to aid in detection of catheter-associated urinary tract infections (CAUTI). Finding clear evidence that a patient does not have an indwelling urinary catheter is useful in making a determination regarding CAUTI. We developed a lexicon of seven core concepts to infer the absence of a urinary catheter. Of the 990,391 concepts extractedby NLP from a large corpus of 744,285 electronic medical notes from 5589 hospitalized patients, 63,516 were labeled as evidence of absence.Human review revealed three primary causes for false negatives. The lexicon and NLP pipeline were refined using this information, resulting in outputs with an acceptable false positive rate of 11%.
Wu, Shan; Zhang, Xiaofeng; Shuai, Jiangbing; Li, Ke; Yu, Huizhen; Jin, Chenchen
2016-07-04
To simplify the PNA-FISH (Peptide nucleic acid-fluorescence in situ hybridization) test, molecular beacon based PNA probe combined with fluorescence scanning detection technology was applied to replace the original microscope observation to detect Listeria monocytogenes The 5′ end and 3′ end of the L. monocytogenes specific PNA probes were labeled with the fluorescent group and the quenching group respectively, to form a molecular beacon based PNA probe. When PNA probe used for fluorescence scanning and N1 treatment as the control, the false positive rate was 11.4%, and the false negative rate was 0; when N2 treatment as the control, the false positive rate decreased to 4.3%, but the false negative rate rose to 18.6%. When beacon based PNA probe used for fluorescence scanning, taken N1 treatment as blank control, the false positive rate was 8.6%, and the false negative rate was 1.4%; taken N2 treatment as blank control, the false positive rate was 5.7%, and the false negative rate was 1.4%. Compared with PNA probe, molecular beacon based PNA probe can effectively reduce false positives and false negatives. The success rates of hybridization of the two PNA probes were 83.3% and 95.2% respectively; and the rates of the two beacon based PNA probes were 91.7% and 90.5% respectively, which indicated that labeling the both ends of the PNA probe dose not decrease the hybridization rate with the target bacteria. The combination of liquid phase PNA-FISH and fluorescence scanning method, can significantly improve the detection efficiency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kipping, David M.; Chen, Jingjing; Sandford, Emily
The analysis of Proxima Centauri’s radial velocities recently led Anglada-Escudé et al. to claim the presence of a low-mass planet orbiting the Sun’s nearest star once every 11.2 days. Although the a priori probability that Proxima b transits its parent star is just 1.5%, the potential impact of such a discovery would be considerable. Independent of recent radial velocity efforts, we observed Proxima Centauri for 12.5 days in 2014 and 31 days in 2015 with the Microwave and Oscillations of Stars space telescope. We report here that we cannot make a compelling case that Proxima b transits in our precisemore » photometric time series. Imposing an informative prior on the period and phase, we do detect a candidate signal with the expected depth. However, perturbing the phase prior across 100 evenly spaced intervals reveals one strong false positive and one weaker instance. We estimate a false-positive rate of at least a few percent and a much higher false-negative rate of 20%–40%, likely caused by the very high flare rate of Proxima Centauri. Comparing our candidate signal to HATSouth ground-based photometry reveals that the signal is somewhat, but not conclusively, disfavored (1 σ –2 σ ), leading us to argue that the signal is most likely spurious. We expect that infrared photometric follow-up could more conclusively test the existence of this candidate signal, owing to the suppression of flare activity and the impressive infrared brightness of the parent star.« less
No Conclusive Evidence for Transits of Proxima b in MOST Photometry
NASA Astrophysics Data System (ADS)
Kipping, David M.; Cameron, Chris; Hartman, Joel D.; Davenport, James R. A.; Matthews, Jaymie M.; Sasselov, Dimitar; Rowe, Jason; Siverd, Robert J.; Chen, Jingjing; Sandford, Emily; Bakos, Gáspár Á.; Jordán, Andrés; Bayliss, Daniel; Henning, Thomas; Mancini, Luigi; Penev, Kaloyan; Csubry, Zoltan; Bhatti, Waqas; Da Silva Bento, Joao; Guenther, David B.; Kuschnig, Rainer; Moffat, Anthony F. J.; Rucinski, Slavek M.; Weiss, Werner W.
2017-03-01
The analysis of Proxima Centauri’s radial velocities recently led Anglada-Escudé et al. to claim the presence of a low-mass planet orbiting the Sun’s nearest star once every 11.2 days. Although the a priori probability that Proxima b transits its parent star is just 1.5%, the potential impact of such a discovery would be considerable. Independent of recent radial velocity efforts, we observed Proxima Centauri for 12.5 days in 2014 and 31 days in 2015 with the Microwave and Oscillations of Stars space telescope. We report here that we cannot make a compelling case that Proxima b transits in our precise photometric time series. Imposing an informative prior on the period and phase, we do detect a candidate signal with the expected depth. However, perturbing the phase prior across 100 evenly spaced intervals reveals one strong false positive and one weaker instance. We estimate a false-positive rate of at least a few percent and a much higher false-negative rate of 20%-40%, likely caused by the very high flare rate of Proxima Centauri. Comparing our candidate signal to HATSouth ground-based photometry reveals that the signal is somewhat, but not conclusively, disfavored (1σ-2σ), leading us to argue that the signal is most likely spurious. We expect that infrared photometric follow-up could more conclusively test the existence of this candidate signal, owing to the suppression of flare activity and the impressive infrared brightness of the parent star.
Flores Mateo, Gemma; Conejero, Jaume; Grenzner Martinel, Elisabet; Baba, Zeki; Dicono, Susana; Echasabal, Mildrey; Gonzalo Santos, Concepción; Aliaga, Arantxa; Barredo, María; Ruiz, Luis; Carrau, Montserrat
2010-07-01
To determine the validity of the rapid antigen test for the diagnoses of acute pharyngitis caused by group A beta-haemolytic Streptococcus (GABHS) compared with culture. Observational study of a consecutive sample of paediatric patients. Two primary care centres (PCC) from the metropolitan area of Barcelona. Children aged 1-14 years with sore throat of no more than 5 days duration were chosen at PCC. Oropharyngeal samples were collected from tonsillar bed and posterior pharynx. A rapid diagnostic test was performed, as well as a throat culture. A total of 211 patients were studied. The overall prevalence of pharyngitis due to Streptococcus was 34.1%. Compared with the throat culture, the sensitivity of the rapid test was 90.3% (95% CI: 81.0-96.0), the specificity was 78.4% (95% CI: 70.6-84.9). The percentage of false negatives was 9.7% and the false positives was 21.6%. Spectrum bias was present, inasmuch as the rapid test sensitivity increased with Centor scores. The diagnostic value of a rapid antigen test for the diagnosis of streptococcal pharyngitis in paediatric patients at PCC is high. However, the percentage of false positives and negatives is too high, and also the sensitivity is too low in patients with fewer symptoms to support the use of rapid antigenic test without culture confirmation and bacterial sensitivity test. 2009 Elsevier España, S.L. All rights reserved.
Implications of false-positive results for future cancer screenings.
Taksler, Glen B; Keating, Nancy L; Rothberg, Michael B
2018-06-01
False-positive cancer screening results may affect a patient's willingness to obtain future screening. The authors conducted logistic regression analysis of 450,484 person-years of electronic medical records (2006-2015) in 92,405 individuals aged 50 to 75 years. Exposures were false-positive breast, prostate, or colorectal cancer screening test results (repeat breast imaging or negative breast biopsy ≤3 months after screening mammography, repeat prostate-specific antigen [PSA] test ≤3 months after PSA test result ≥4.0 ng/mL or negative prostate biopsy ≤3 months after any PSA result, or negative colonoscopy [without biopsy/polypectomy] ≤6 months after a positive fecal occult blood test). Outcomes were up-to-date status with breast or colorectal cancer screening. Covariates included prior screening history, clinical information (eg, family history, obesity, and smoking status), comorbidity, and demographics. Women were more likely to be up to date with breast cancer screening if they previously had false-positive mammography findings (adjusted odds ratio [AOR], 1.43 [95% confidence interval, 1.34-1.51] without breast biopsy and AOR, 2.02 [95% confidence interval, 1.56-2.62] with breast biopsy; both P<.001). The same women were more likely to be up to date with colorectal cancer screening (AOR range, 1.25-1.47 depending on breast biopsy; both P<.001). Men who previously had false-positive PSA testing were more likely to be up to date with colorectal cancer screening (AOR, 1.22 [P = .039] without prostate imaging/biopsy and AOR, 1.60 [P = .028] with imaging/biopsy). Results were stronger for individuals with more false-positive results (all P≤.005). However, women with previous false-positive colorectal cancer fecal occult blood test screening results were found to be less likely to be up to date with breast cancer screening (AOR, 0.73; P<.001). Patients who previously had a false-positive breast or prostate cancer screening test were more likely to engage in future screening. Cancer 2018;124:2390-8. © 2018 American Cancer Society. © 2018 American Cancer Society.
Theron, Grant; Venter, Rouxjeane; Smith, Liezel; Esmail, Aliasgar; Randall, Philippa; Sood, Vishesh; Oelfese, Suzette; Calligaro, Greg; Warren, Robin; Dheda, Keertan
2018-03-01
Globally, Xpert MTB/RIF (Xpert) is the most widely used PCR test for the diagnosis of tuberculosis (TB). Positive results in previously treated patients, which are due to old DNA or active disease, are a diagnostic dilemma. We prospectively retested sputum from 238 patients, irrespective of current symptoms, who were previously diagnosed to be Xpert positive and treated successfully. Patients who retested as Xpert positive and culture negative were exhaustively investigated (repeat culture, chest radiography, bronchoscopy with bronchoalveolar lavage, long-term clinical follow-up). We evaluated whether the duration since previous treatment completion, mycobacterial burden (the Xpert cycle threshold [ C T ] value), and reclassification of Xpert-positive results with a very low semiquantitation level to Xpert-negative results reduced the rate of false positivity. A total of 229/238 (96%) of patients were culture negative. Sixteen of 229 (7%) were Xpert positive a median of 11 months (interquartile range, 5 to 19 months) after treatment completion. The specificity was 93% (95% confidence interval [CI], 89 to 96%). Nine of 15 (40%) Xpert-positive, culture-negative patients reverted to Xpert negative after 2 to 3 months (1 patient declined further participation). Patients with false-positive Xpert results had a lower mycobacterial burden than patients with true-positive Xpert results ( C T , 28.7 [95% CI, 27.2 to 30.4] versus 17.6 [95% CI, 16.9 to 18.2]; P < 0.001), an increased likelihood of a chest radiograph not compatible with active TB (5/15 patients versus 0/5 patients; P = 0.026), and less-viscous sputum (15/16 patients versus 2/5 patients whose sputum was graded as mucoid or less; P = 0.038). All patients who initially retested as Xpert positive and culture negative ("Xpert false positive") were clinically well without treatment after follow-up. The duration since the previous treatment poorly predicted false-positive results (a duration of ≤2 years identified only 66% of patients with false-positive results). Reclassifying Xpert-positive results with a very low semiquantitation level to Xpert negative improved the specificity (+3% [95% CI, +2 to +5%]) but reduced the sensitivity (-10% [95% CI, -4 to -15%]). Patients with previous TB retested with Xpert can have false-positive results and thus not require treatment. These data inform clinical practice by highlighting the challenges in interpreting Xpert-positive results, underscore the need for culture, and have implications for next-generation ultrasensitive tests. Copyright © 2018 American Society for Microbiology.
An investigation into false-negative transthoracic fine needle aspiration and core biopsy specimens.
Minot, Douglas M; Gilman, Elizabeth A; Aubry, Marie-Christine; Voss, Jesse S; Van Epps, Sarah G; Tuve, Delores J; Sciallis, Andrew P; Henry, Michael R; Salomao, Diva R; Lee, Peter; Carlson, Stephanie K; Clayton, Amy C
2014-12-01
Transthoracic fine needle aspiration (TFNA)/core needle biopsy (CNB) under computed tomography (CT) guidance has proved useful in the assessment of pulmonary nodules. We sought to determine the TFNA false-negative (FN) rate at our institution and identify potential causes of FN diagnoses. Medical records were reviewed from 1,043 consecutive patients who underwent CT-guided TFNA with or without CNB of lung nodules over a 5-year time period (2003-2007). Thirty-seven FN cases of "negative" TFNA/CNB with malignant outcome were identified with 36 cases available for review, of which 35 had a corresponding CNB. Cases were reviewed independently (blinded to original diagnosis) by three pathologists with 15 age- and sex-matched positive and negative controls. Diagnosis (i.e., nondiagnostic, negative or positive for malignancy, atypical or suspicious) and qualitative assessments were recorded. Consensus diagnosis was suspicious or positive in 10 (28%) of 36 TFNA cases and suspicious in 1 (3%) of 35 CNB cases, indicating potential interpretive errors. Of the 11 interpretive errors (including both suspicious and positive cases), 8 were adenocarcinomas, 1 squamous cell carcinoma, 1 metastatic renal cell carcinoma, and 1 lymphoma. The remaining 25 FN cases (69.4%) were considered sampling errors and consisted of 7 adenocarcinomas, 3 nonsmall cell carcinomas, 3 lymphomas, 2 squamous cell carcinomas, and 2 renal cell carcinomas. Interpretive and sampling error cases were more likely to abut the pleura, while histopathologically, they tended to be necrotic and air-dried. The overall FN rate in this patient cohort is 3.5% (1.1% interpretive and 2.4% sampling errors). © 2014 Wiley Periodicals, Inc.
Are Hemorrhoids Associated with False-Positive Fecal Immunochemical Test Results?
Kim, Nam Hee; Park, Jung Ho; Park, Dong Il; Sohn, Chong Il; Choi, Kyuyong; Jung, Yoon Suk
2017-01-01
False-positive (FP) results of fecal immunochemical tests (FITs) conducted in colorectal cancer (CRC) screening could lead to performing unnecessary colonoscopies. Hemorrhoids are a possible cause of FP FIT results; however, studies on this topic are extremely rare. We investigated whether hemorrhoids are associated with FP FIT results. A retrospective study was conducted at a university hospital in Korea from June 2013 to May 2015. Of the 34547 individuals who underwent FITs, 3946 aged ≥50 years who underwent colonoscopies were analyzed. Logistic regression analysis was performed to determine factors associated with FP FIT results. Among 3946 participants, 704 (17.8%) showed positive FIT results and 1303 (33.0%) had hemorrhoids. Of the 704 participants with positive FIT results, 165 had advanced colorectal neoplasia (ACRN) and 539 had no ACRN (FP results). Of the 1303 participants with hemorrhoids, 291 showed FP results, of whom 81 showed FP results because of hemorrhoids only. Participants with hemorrhoids had a higher rate of FP results than those without hemorrhoids (291/1176, 24.7% vs. 248/2361, 10.5%; p<0.001). Additionally, the participants with hemorrhoids as the only abnormality had a higher rate of FP results than those experiencing no such abnormalities (81/531, 15.3% vs. 38/1173, 3.2%; p<0.001). In multivariate analysis, the presence of hemorrhoids was identified as an independent predictor of FP results (adjusted odds ratio, 2.76; 95% confidence interval, 2.24-3.40; p<0.001). Hemorrhoids are significantly associated with FP FIT results. Their presence seemed to be a non-negligible contributor of FP results in FIT-based CRC screening programs.
Román, R.; Sala, M.; Salas, D.; Ascunce, N.; Zubizarreta, R.; Castells, X.
2012-01-01
Background: Reducing the false-positive risk in breast cancer screening is important. We examined how the screening-protocol and women's characteristics affect the cumulative false-positive risk. Methods: This is a retrospective cohort study of 1 565 364 women aged 45–69 years who underwent 4 739 498 screening mammograms from 1990 to 2006. Multilevel discrete hazard models were used to estimate the cumulative false-positive risk over 10 sequential mammograms under different risk scenarios. Results: The factors affecting the false-positive risk for any procedure and for invasive procedures were double mammogram reading [odds ratio (OR) = 2.06 and 4.44, respectively], two mammographic views (OR = 0.77 and 1.56, respectively), digital mammography (OR = 0.83 for invasive procedures), premenopausal status (OR = 1.31 and 1.22, respectively), use of hormone replacement therapy (OR = 1.03 and 0.84, respectively), previous invasive procedures (OR = 1.52 and 2.00, respectively), and a familial history of breast cancer (OR = 1.18 and 1.21, respectively). The cumulative false-positive risk for women who started screening at age 50–51 was 20.39% [95% confidence interval (CI) 20.02–20.76], ranging from 51.43% to 7.47% in the highest and lowest risk profiles, respectively. The cumulative risk for invasive procedures was 1.76% (95% CI 1.66–1.87), ranging from 12.02% to 1.58%. Conclusions: The cumulative false-positive risk varied widely depending on the factors studied. These findings are relevant to provide women with accurate information and to improve the effectiveness of screening programs. PMID:21430183
Grégoire, Y; Germain, M; Delage, G
2018-05-01
Since 25 May 2010, all donors at our blood centre who tested false-positive for HIV, HBV, HCV or syphilis are eligible for re-entry after further testing. Donors who have a second false-positive screening test, either during qualification for or after re-entry, are deferred for life. This study reports on factors associated with the occurrence of such deferrals. Rates of second false-positive results were compared by year of deferral, transmissible disease marker, gender, age, donor status (new or repeat) and testing platform (same or different) both at qualification for re-entry and afterwards. Chi-square tests were used to compare proportions. Cox regression was used for multivariate analyses. Participation rates in the re-entry programme were 42·1%: 25·6% failed to qualify for re-entry [different platform: 2·7%; same platform: 42·9% (P < 0·0001)]. After re-entry, rates of deferral for second false-positive results were 8·4% after 3 years [different platform: 1·8%; same platform: 21·4% (P < 0·0001)]. Deferral rates were higher for HIV and HCV than for HBV at qualification when tested on the same platform. The risk, when analysed by multivariate analyses, of a second deferral for a false-positive result, both at qualification and 3 years after re-entry, was lower for donors deferred on a different platform; this risk was higher for HIV, HCV and syphilis than for HBV and for new donors if tested on the same platform. Re-entry is more often successful when donors are tested on a testing platform different from the one on which they obtained their first false-positive result. © 2018 International Society of Blood Transfusion.
Pataky, Todd C; Vanrenterghem, Jos; Robinson, Mark A
2016-06-14
A false positive is the mistake of inferring an effect when none exists, and although α controls the false positive (Type I error) rate in classical hypothesis testing, a given α value is accurate only if the underlying model of randomness appropriately reflects experimentally observed variance. Hypotheses pertaining to one-dimensional (1D) (e.g. time-varying) biomechanical trajectories are most often tested using a traditional zero-dimensional (0D) Gaussian model of randomness, but variance in these datasets is clearly 1D. The purpose of this study was to determine the likelihood that analyzing smooth 1D data with a 0D model of variance will produce false positives. We first used random field theory (RFT) to predict the probability of false positives in 0D analyses. We then validated RFT predictions via numerical simulations of smooth Gaussian 1D trajectories. Results showed that, across a range of public kinematic, force/moment and EMG datasets, the median false positive rate was 0.382 and not the assumed α=0.05, even for a simple two-sample t test involving N=10 trajectories per group. The median false positive rate for experiments involving three-component vector trajectories was p=0.764. This rate increased to p=0.945 for two three-component vector trajectories, and to p=0.999 for six three-component vectors. This implies that experiments involving vector trajectories have a high probability of yielding 0D statistical significance when there is, in fact, no 1D effect. Either (a) explicit a priori identification of 0D variables or (b) adoption of 1D methods can more tightly control α. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gabriel, Michael; Decristoforo, Clemens; Donnemiller, Eveline; Ulmer, Hanno; Watfah Rychlinski, Christine; Mather, Stephen J; Moncayo, Roy
2003-05-01
The aim of this study was to compare the imaging abilities of the recently developed somatostatin analog, (99m)Tc-hydrazinonicotinyl-Tyr(3)-octreotide ((99m)Tc-HYNIC-TOC [(99m)Tc-TOC]), with (111)In-diethylenediaminepentaacetic acid-D-Phe(1)-octreotide ((111)In-OCT [Octreoscan]) in patients undergoing routine somatostatin receptor (SSTR) scintigraphy. Forty-one patients (20 men, 21 women; age range, 29-75 y; mean age, 56.7 y) with either histologically proven or biologically and clinically suspected endocrine tumors were enrolled in the study. Four groups were distinguished: (a) patients being evaluated for the detection and localization of neuroendocrine tumors (n = 6), (b) tumor staging (n = 19), (c) patients being investigated to determine the SSTR status of tumor lesions (n = 11), and (d) patient follow-up studies (n = 5). Each patient received a mean activity of 150 MBq (111)In-OCT and 350-400 MBq (99m)Tc-TOC. Scintigraphy with (99m)Tc-TOC was performed 4 h after injection and scintigraphy with (111)In-OCT was performed 4 and 24 h after injection. SPECT studies of areas of interest were performed 4 h after injection for both tracers as well as at 24 h after injection for (111)In-OCT. The time interval between the studies using each tracer ranged from 2 to 22 d (mean interval, 9.3 d). (111)In-OCT and (99m)Tc-TOC showed an equivalent scan result in 32 patients (78%), 9 cases showed discrepancies (22%), false-negative results with (111)In-OCT were seen in 6 cases (14.6%), whereas (99m)Tc-TOC was false-positive in 2 cases (4.9%). (111)In-OCT was true-negative in both cases. The false-positive findings of the (99m)Tc-TOC studies were caused by nonspecific uptake in the bowel. In 1 case, (99m)Tc-TOC correctly identified a metastasis in the lumbar spine but both scan results were false-positive because of an inflammatory process. In 21 patients with SSTR-expressing tumors, the semiquantitative region-of-interest analysis showed that (99m)Tc-TOC achieved higher tumor-to-normal tissue ratios than (111)In-OCT. This study revealed a higher sensitivity of (99m)Tc-TOC as compared with (111)In-OCT as an imaging agent for the localization of SSTR-expressing tumors. To avoid false-positive findings with (99m)Tc-OCT due to nonspecific tracer accumulation, additional scanning at 1-2 h after injection should be done.
Development of Technologies for Early Detection and Stratification of Breast Cancer
2012-10-01
at the time of screening, and has an 8-10% false positive rate.3 These drawbacks lead to inaccurate patient diagnosis, which can allow potentially...95% recovery efficiency. Furthermore, using whole blood from healthy donors, we determined we have a zero false positive rate; that is, we have not...detected a single false positive event out of the dozen samples we ran. The technology we developed here is not only useful for the isolation of CTCs
Rare earth elements (REE) and certain alkaline earths can produce M+2 interferences in ICP-MS because they have sufficiently low second ionization energies. Four REEs (150Sm, 150Nd, 156Gd and 156Dy) produce false positives on 75As and 78Se and 132Ba can produce a false positive ...
El-Assmy, Ahmed; El-Tholoth, Hossam S; Abou-El-Ghar, Mohamed E; Mohsen, Tarek; Ibrahiem, El Housseiny I
2010-06-01
We determined the value of clinical and radiological findings in diagnosis of false penile fracture. Also, the long-term outcome of conservative and surgical treatment of such patients was evaluated. Seventeen patients with false penile fracture were treated conservatively (3 patients) and surgically (14 patients) at our center. Medical records were retrospectively reviewed for etiology, symptoms, signs of physical examination, and information on findings of surgical exploration. Data on erectile function and penile sequelae were obtained during follow-up using the Sexual Health Inventory for Men (SHIM) questionnaire and local examination. The most common cause of false penile fracture is sexual intercourse (76.5%). False fracture was suspected in 3 patients who presented with small hematoma and slow post-trauma detumescence; intact tunicas were diagnosed by magnetic resonance imaging (MRI) in all of them and were managed conservatively. Surgical penile exploration was performed in 14 cases, in whom preoperative ultrasound was done in 6, and it was false positive for presence of tunical tear in 50%. Exploration revealed nonspecific dartos bleeding in 9 cases and avulsed superficial dorsal vein in 5. Long-term follow-up (mean=93 months) was available for 16 patients, among whom there was no complications. In most cases, false penile fracture is indistinguishable from true penile fracture either clinically or radiologically. In atypical cases, MRI seems to be a promising modality for diagnosis of such patients. The long-term outcome of conservative and surgical treatment is excellent. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Zandieh, Shahin; Schütz, Matthias; Bernt, Reinhard; Zwerina, Jochen; Haller, Joerg
2013-01-01
We report the case of a 50-year-old woman presented with a history of right hemicolectomy due to an ileocecal neuroendocrine tumor and left breast metastasis. Owing to a slightly elevated chromogranin A-level and lower abdominal pain, single photon emission computed tomography-computer tomography (SPECT-CT) was performed. There were no signs of recurrence on the SPECT-CT scan, but the patient was incidentally found to have an inflamed intramural myoma. We believe that the slightly elevated chromogranin A-level was caused by the hypertension that the patient presented. In the clinical context, this is a report of an inflamed uterine myoma seen as a false positive result detected by TC-99m-Tc-EDDA/HYNIC-Tyr3-Octreotide (Tektrotyd) SPECT-CT hybrid imaging.
Oxybuprocaine induces a false-positive response in immunochromatographic SAS Adeno Test.
Hoshino, Takeshi; Takanashi, Taiji; Okada, Morio; Uchida, Sunao
2002-04-01
To investigate whether a solution of oxybuprocaine hydrochloride, 0.4%, results in a false-positive response in an immunochromatographic SAS Adeno Test. Experimental study. Physiologic saline and 2% lidocaine. Each chemical (100 microl) was diluted in a transport medium. Five drops (200 microl) of the resultant solution were dispensed into the round sample well of a test device. Fifteen samples were tested in each group. Ten minutes after the start of the test, a colored line in the "specimen" portion of the test membrane was visually read as positive or negative by a masked technician. No positive reaction was observed in the control groups (physiologic saline and lidocaine). A false-positive reaction was observed in six samples (33.3%) in the oxybuprocaine group. The positive rate was significantly higher in the oxybuprocaine group compared with those in control groups (P = 0.0062, Fisher's extract probability test). Oxybuprocaine may induce a false-positive reaction in an immunochromatographic SAS Adeno Test. We recommend the use of lidocaine, instead of oxybuprocaine, for local anesthesia in taking eye swabs from patients with suspected adenovirus infection.
Visual field progression in glaucoma: what is the specificity of the Guided Progression Analysis?
Artes, Paul H; O'Leary, Neil; Nicolela, Marcelo T; Chauhan, Balwantray C; Crabb, David P
2014-10-01
To estimate the specificity of the Guided Progression Analysis (GPA) (Carl Zeiss Meditec, Dublin, CA) in individual patients with glaucoma. Observational cohort study. Thirty patients with open-angle glaucoma. In 30 patients with open-angle glaucoma, 1 eye (median mean deviation [MD], -2.5 decibels [dB]; interquartile range, -4.4 to -1.3 dB) was tested 12 times over 3 months (Humphrey Field Analyzer, Carl Zeiss Meditec; SITA Standard, 24-2). "Possible progression" and "likely progression" were determined with the GPA. These analyses were repeated after the order of the tests had been randomly rearranged (1000 unique permutations). Rate of false-positive alerts of "possible progression" and "likely progression" with the GPA. On average, the specificity of the GPA "likely progression" alert was high-for the entire sample, the mean rate of false-positive alerts after 10 follow-up tests was 2.6%. With "possible progression," the specificity was considerably lower (false-positive rate, 18.5%). Most important, the cumulative rate of false-positive alerts varied substantially among patients, from <1% to 80% with "possible progression" and from <0.1% to 20% with "likely progression." Factors associated with false-positive alerts were visual field variability (standard deviation of MD, Spearman's rho = 0.41, P<0.001) and the reliability indices (proportion of false-positive and false-negative responses, fixation losses, rho>0.31, P≤0.10). On average, progression criteria currently used in the GPA have high specificity, but some patients are more likely to show false-positive alerts than others. This is a natural consequence of population-based change criteria and may not matter in clinical trials and studies in which large groups of patients are compared. However, it must be considered when the GPA is used in clinical practice where specificity needs to be controlled for individual patients. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Do positive schizotypal symptoms predict false perceptual experiences in nonclinical populations?
Tsakanikos, Elias; Reed, Phil
2005-12-01
We examined whether positive schizotypy (i.e., reports of hallucinatory and delusional-like experiences) in nonclinical participants could predict false perceptual experiences during detection of fast-moving words beyond a possible response bias. The participants (N = 160) were assigned to one of two conditions: they were asked either to make presence/absence judgments (loose criterion) or to read aloud every detected word (strict criterion). Regression analysis showed that high levels of positive schizotypy predicted false alarms in the loose condition and false perceptions of words in the strict condition. The obtained effects were independent of detection accuracy, task order, impulsivity, and social desirability. We discuss the results in the context of information processing biases linked to the positive symptomatology of schizophrenia. Clinical and theoretical implications are also considered.
False Memory in Adults With ADHD: A Comparison Between Subtypes and Normal Controls.
Soliman, Abdrabo Moghazy; Elfar, Rania Mohamed
2017-10-01
To examine the performance on the Deese-Roediger-McDermott task of adults divided into ADHD subtypes and compares their performance to that of healthy controls to examine whether adults with ADHD are more susceptible to the production of false memories under experimental conditions. A total of 128 adults with ADHD (50% females), classified into three Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV-TR) subtypes, were compared with 48 controls. The results indicated that the ADHD participants recalled and recognized fewer studied words than the controls, the ADHD groups produced more false memories than the control group, no differences in either the false positives or the false negatives. The ADHD-combined (ADHD-CT) group recognized significantly more critical words than the control, ADHD-predominantly inattentive (ADHD-IA), and ADHD-predominantly hyperactive-impulsive (ADHD-HI) groups. The ADHD groups recalled and recognized more false positives, were more confident in their false responses, and displayed more knowledge corruption than the controls. The ADHD-CT group recalled and recognized more false positives than the other ADHD groups. The adults with ADHD have more false memories than the controls and that false memory formation varied with the ADHD subtypes.
2012-01-01
Background Verbal autopsy has been widely used to estimate causes of death in settings with inadequate vital registries, but little is known about its validity. This analysis was part of Addis Ababa Mortality Surveillance Program to examine the validity of verbal autopsy for determining causes of death compared with hospital medical records among adults in the urban setting of Ethiopia. Methods This validation study consisted of comparison of verbal autopsy final diagnosis with hospital diagnosis taken as a “gold standard”. In public and private hospitals of Addis Ababa, 20,152 adult deaths (15 years and above) were recorded between 2007 and 2010. With the same period, a verbal autopsy was conducted for 4,776 adult deaths of which, 1,356 were deceased in any of Addis Ababa hospitals. Then, verbal autopsy and hospital data sets were merged using the variables; full name of the deceased, sex, address, age, place and date of death. We calculated sensitivity, specificity and positive predictive values with 95% confidence interval. Results After merging, a total of 335 adult deaths were captured. For communicable diseases, the values of sensitivity, specificity and positive predictive values of verbal autopsy diagnosis were 79%, 78% and 68% respectively. For non-communicable diseases, sensitivity of the verbal autopsy diagnoses was 69%, specificity 78% and positive predictive value 79%. Regarding injury, sensitivity of the verbal autopsy diagnoses was 70%, specificity 98% and positive predictive value 83%. Higher sensitivity was achieved for HIV/AIDS and tuberculosis, but lower specificity with relatively more false positives. Conclusion These findings may indicate the potential of verbal autopsy to provide cost-effective information to guide policy on communicable and non communicable diseases double burden among adults in Ethiopia. Thus, a well structured verbal autopsy method, followed by qualified physician reviews could be capable of providing reasonable cause specific mortality estimates in Ethiopia. However, the limited generalizability of this study due to the fact that matched verbal autopsy deaths were all in-hospital deaths in an urban center, thus results may not be generalizable to rural home deaths. Such application and refinement of existing verbal autopsy methods holds out the possibility of obtaining replicable, sustainable and internationally comparable mortality statistics of known quality. Similar validation studies need to be undertaken considering the limitation of medical records as “gold standard” since records may not be confirmed using laboratory investigations or medical technologies. The validation studies need to address child and maternal causes of death and possibly all underlying causes of death. PMID:22928712
VarBin, a novel method for classifying true and false positive variants in NGS data
2013-01-01
Background Variant discovery for rare genetic diseases using Illumina genome or exome sequencing involves screening of up to millions of variants to find only the one or few causative variant(s). Sequencing or alignment errors create "false positive" variants, which are often retained in the variant screening process. Methods to remove false positive variants often retain many false positive variants. This report presents VarBin, a method to prioritize variants based on a false positive variant likelihood prediction. Methods VarBin uses the Genome Analysis Toolkit variant calling software to calculate the variant-to-wild type genotype likelihood ratio at each variant change and position divided by read depth. The resulting Phred-scaled, likelihood-ratio by depth (PLRD) was used to segregate variants into 4 Bins with Bin 1 variants most likely true and Bin 4 most likely false positive. PLRD values were calculated for a proband of interest and 41 additional Illumina HiSeq, exome and whole genome samples (proband's family or unrelated samples). At variant sites without apparent sequencing or alignment error, wild type/non-variant calls cluster near -3 PLRD and variant calls typically cluster above 10 PLRD. Sites with systematic variant calling problems (evident by variant quality scores and biases as well as displayed on the iGV viewer) tend to have higher and more variable wild type/non-variant PLRD values. Depending on the separation of a proband's variant PLRD value from the cluster of wild type/non-variant PLRD values for background samples at the same variant change and position, the VarBin method's classification is assigned to each proband variant (Bin 1 to Bin 4). Results To assess VarBin performance, Sanger sequencing was performed on 98 variants in the proband and background samples. True variants were confirmed in 97% of Bin 1 variants, 30% of Bin 2, and 0% of Bin 3/Bin 4. Conclusions These data indicate that VarBin correctly classifies the majority of true variants as Bin 1 and Bin 3/4 contained only false positive variants. The "uncertain" Bin 2 contained both true and false positive variants. Future work will further differentiate the variants in Bin 2. PMID:24266885
Multiview face detection based on position estimation over multicamera surveillance system
NASA Astrophysics Data System (ADS)
Huang, Ching-chun; Chou, Jay; Shiu, Jia-Hou; Wang, Sheng-Jyh
2012-02-01
In this paper, we propose a multi-view face detection system that locates head positions and indicates the direction of each face in 3-D space over a multi-camera surveillance system. To locate 3-D head positions, conventional methods relied on face detection in 2-D images and projected the face regions back to 3-D space for correspondence. However, the inevitable false face detection and rejection usually degrades the system performance. Instead, our system searches for the heads and face directions over the 3-D space using a sliding cube. Each searched 3-D cube is projected onto the 2-D camera views to determine the existence and direction of human faces. Moreover, a pre-process to estimate the locations of candidate targets is illustrated to speed-up the searching process over the 3-D space. In summary, our proposed method can efficiently fuse multi-camera information and suppress the ambiguity caused by detection errors. Our evaluation shows that the proposed approach can efficiently indicate the head position and face direction on real video sequences even under serious occlusion.
Kufa, Tendesayi; Kharsany, Ayesha BM; Cawood, Cherie; Khanyile, David; Lewis, Lara; Grobler, Anneke; Chipeta, Zawadi; Bere, Alfred; Glenshaw, Mary; Puren, Adrian
2017-01-01
Abstract Introduction: We describe the overall accuracy and performance of a serial rapid HIV testing algorithm used in community-based HIV testing in the context of a population-based household survey conducted in two sub-districts of uMgungundlovu district, KwaZulu-Natal, South Africa, against reference fourth-generation HIV-1/2 antibody and p24 antigen combination immunoassays. We discuss implications of the findings on rapid HIV testing programmes. Methods: Cross-sectional design: Following enrolment into the survey, questionnaires were administered to eligible and consenting participants in order to obtain demographic and HIV-related data. Peripheral blood samples were collected for HIV-related testing. Participants were offered community-based HIV testing in the home by trained field workers using a serial algorithm with two rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using two fourth-generation immunoassays with all positives in the confirmatory test considered true positives. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value and false-positive and false-negative rates were determined. Results: Of 10,236 individuals enrolled in the survey, 3740 were tested in the home (median age 24 years (interquartile range 19–31 years), 42.1% males and HIV positivity on RDT algorithm 8.0%). From those tested, 3729 (99.7%) had a definitive RDT result as well as a laboratory immunoassay result. The overall accuracy of the RDT when compared to the fourth-generation immunoassays was 98.8% (95% confidence interval (CI) 98.5–99.2). The sensitivity, specificity, positive predictive value and negative predictive value were 91.1% (95% CI 87.5–93.7), 99.9% (95% CI 99.8–100), 99.3% (95% CI 97.4–99.8) and 99.1% (95% CI 98.8–99.4) respectively. The false-positive and false-negative rates were 0.06% (95% CI 0.01–0.24) and 8.9% (95% CI 6.3–12.53). Compared to true positives, false negatives were more likely to be recently infected on limited antigen avidity assay and to report antiretroviral therapy (ART) use. Conclusions: The overall accuracy of the RDT algorithm was high. However, there were few false positives, and the sensitivity was lower than expected with high false negatives, despite implementation of quality assurance measures. False negatives were associated with recent (early) infection and ART exposure. The RDT algorithm was able to correctly identify the majority of HIV infections in community-based HIV testing. Messaging on the potential for false positives and false negatives should be included in these programmes. PMID:28872274
Li, A; Meyre, D
2013-04-01
A robust replication of initial genetic association findings has proved to be difficult in human complex diseases and more specifically in the obesity field. An obvious cause of non-replication in genetic association studies is the initial report of a false positive result, which can be explained by a non-heritable phenotype, insufficient sample size, improper correction for multiple testing, population stratification, technical biases, insufficient quality control or inappropriate statistical analyses. Replication may, however, be challenging even when the original study describes a true positive association. The reasons include underpowered replication samples, gene × gene, gene × environment interactions, genetic and phenotypic heterogeneity and subjective interpretation of data. In this review, we address classic pitfalls in genetic association studies and provide guidelines for proper discovery and replication genetic association studies with a specific focus on obesity.
Palmier, James; Lanzrath, Brian; Dixon, Ammon; Idowu, Oluseun
2014-01-01
To identify and quantify demographic correlates of false-negative self-reporting of tobacco use in life insurance applicants. Several studies have assessed the sensitivity of self-reporting for tobacco use in various populations, but statistical examination of the causes of misreporting has been rarer. The very large (488,000 confirmed tobacco users) sample size, US-wide geographic scope, and unique incentive structure of the life insurance application process permit more robust and insurance industry-specific results in this study. Approximately 6.2 million life insurance applicants for whom both tobacco-use interview questions and a confirmatory urine cotinine test were completed between 1999 and 2012 were evaluated for consistency between self-reported and laboratory-confirmed tobacco-use status. The data set was subjected to logistic regression to identify predictors of false negative self-reports (FNSR). False-negative self-reporting was found to be strongly associated with male gender, applicant ages of less than 30 or greater than 60, and low cotinine positivity rates in the applicant's state of residence. Policy face value was also moderately predictive, values above $500,000 associated with moderately higher FNSR. The findings imply that FNSR in life insurance applicants may be the result of complex interactions among financial incentives, geography and presumptive peer groups, and gender.
Dehon, Hedwige; Larøi, Frank; Van der Linden, Martial
2010-10-01
This study examined the influence of emotional valence on the production of DRM false memories (Roediger & McDermott, 1995). Participants were presented with neutral, positive, or negative DRM lists for a later recognition (Experiment 1) or recall (Experiment 2) test. In both experiments, confidence and recollective experience (i.e., "Remember-Know" judgments; Tulving, 1985) were also assessed. Results consistently showed that, compared with neutral lists, affective lists induced more false recognition and recall of nonpresented critical lures. Moreover, although confidence ratings did not differ between the false remembering from the different kinds of lists, "Remember" responses were more often associated with negative than positive and neutral false remembering of the critical lures. In contrast, positive false remembering of the critical lures was more often associated with "Know" responses. These results are discussed in light of the Paradoxical Negative Emotion (PNE) hypothesis (Porter, Taylor, & ten Bricke, 2008). (PsycINFO Database Record (c) 2010 APA, all rights reserved).
2006-10-01
lead to false positive segmental hair analysis results.13 Due to the increased risk of false positives associated with segmental hair analysis ...to 200 mg of hair (to allow confirmation testing). 7 The segments are typically washed to remove external contaminants and the chemicals in the hair ...further confirmation. The method overcomes the false positives associated with traditional segmental hair analysis such. By measuring the
Ribeiro, Antonio; Golicz, Agnieszka; Hackett, Christine Anne; Milne, Iain; Stephen, Gordon; Marshall, David; Flavell, Andrew J; Bayer, Micha
2015-11-11
Single Nucleotide Polymorphisms (SNPs) are widely used molecular markers, and their use has increased massively since the inception of Next Generation Sequencing (NGS) technologies, which allow detection of large numbers of SNPs at low cost. However, both NGS data and their analysis are error-prone, which can lead to the generation of false positive (FP) SNPs. We explored the relationship between FP SNPs and seven factors involved in mapping-based variant calling - quality of the reference sequence, read length, choice of mapper and variant caller, mapping stringency and filtering of SNPs by read mapping quality and read depth. This resulted in 576 possible factor level combinations. We used error- and variant-free simulated reads to ensure that every SNP found was indeed a false positive. The variation in the number of FP SNPs generated ranged from 0 to 36,621 for the 120 million base pairs (Mbp) genome. All of the experimental factors tested had statistically significant effects on the number of FP SNPs generated and there was a considerable amount of interaction between the different factors. Using a fragmented reference sequence led to a dramatic increase in the number of FP SNPs generated, as did relaxed read mapping and a lack of SNP filtering. The choice of reference assembler, mapper and variant caller also significantly affected the outcome. The effect of read length was more complex and suggests a possible interaction between mapping specificity and the potential for contributing more false positives as read length increases. The choice of tools and parameters involved in variant calling can have a dramatic effect on the number of FP SNPs produced, with particularly poor combinations of software and/or parameter settings yielding tens of thousands in this experiment. Between-factor interactions make simple recommendations difficult for a SNP discovery pipeline but the quality of the reference sequence is clearly of paramount importance. Our findings are also a stark reminder that it can be unwise to use the relaxed mismatch settings provided as defaults by some read mappers when reads are being mapped to a relatively unfinished reference sequence from e.g. a non-model organism in its early stages of genomic exploration.
Sonek, Jiri; Krantz, David; Carmichael, Jon; Downing, Cathy; Jessup, Karen; Haidar, Ziad; Ho, Shannon; Hallahan, Terrence; Kliman, Harvey J; McKenna, David
2018-01-01
Preeclampsia is a major cause of perinatal morbidity and mortality. First-trimester screening has been shown to be effective in selecting patients at an increased risk for preeclampsia in some studies. We sought to evaluate the feasibility of screening for preeclampsia in the first trimester based on maternal characteristics, medical history, biomarkers, and placental volume. This is a prospective observational nonintervention cohort study in an unselected US population. Patients who presented for an ultrasound examination between 11-13+6 weeks' gestation were included. The following parameters were assessed and were used to calculate the risk of preeclampsia: maternal characteristics (demographic, anthropometric, and medical history), maternal biomarkers (mean arterial pressure, uterine artery pulsatility index, placental growth factor, pregnancy-associated plasma protein A, and maternal serum alpha-fetoprotein), and estimated placental volume. After delivery, medical records were searched for the diagnosis of preeclampsia. Detection rates for early-onset preeclampsia (<34 weeks' gestation) and later-onset preeclampsia (≥34 weeks' gestation) for 5% and 10% false-positive rates using various combinations of markers were calculated. We screened 1288 patients of whom 1068 (82.99%) were available for analysis. In all, 46 (4.3%) developed preeclampsia, with 13 (1.22%) having early-onset preeclampsia and 33 (3.09%) having late-onset preeclampsia. Using maternal characteristics, serum biomarkers, and uterine artery pulsatility index, the detection rate of early-onset preeclampsia for either 5% or 10% false-positive rate was 85%. With the same protocol, the detection rates for preeclampsia with delivery <37 weeks were 52% and 60% for 5% and 10% false-positive rates, respectively. Based on maternal characteristics, the detection rates for late-onset preeclampsia were 15% and 48% for 5% and 10%, while for preeclampsia at ≥37 weeks' gestation the detection rates were 24% and 43%, respectively. The detection rates for late-onset preeclampsia and preeclampsia with delivery at >37 weeks' gestation were not improved by the addition of biomarkers. Screening for preeclampsia at 11-13+6 weeks' gestation using maternal characteristics and biomarkers is associated with a high detection rate for a low false-positive rate. Screening for late-onset preeclampsia yields a much poorer performance. In this study the utility of estimated placental volume and mean arterial pressure was limited but larger studies are needed to ultimately determine the effectiveness of these markers. Copyright © 2017 Elsevier Inc. All rights reserved.
Definition of rainfall thresholds for shallow landslide early warning in Italy
NASA Astrophysics Data System (ADS)
Cancelliere, A.; Peres, D. J.
2011-12-01
Extreme rainfall is the main cause of shallow landslides. For risk mitigation, landslide early warning systems can be implemented, on the basis of rainfall monitoring and forecasting, and the use of a landslide triggering model. Several empirical, also referred to as statistical, rainfall-landslide triggering models have been proposed in the scientific literature, and used for early warning systems activated worldwide. Nonetheless, it is not clear how effective are landslide warning systems, and it is difficult to quantify the induced benefits for the implemented ones. Many rainfall thresholds have been determined through the statistical analysis of the rainfall events that have been the cause of past landslides only, thus neglecting the cases of true negatives and false positives, with negative effects on the robustness of the proposed threshold and, probably, on the effectiveness of the warning system. In the present work we address the issue of establishing warning thresholds, which, although in an approximate way, account for the related benefits. We propose the maximization of an objective function, that measures the trade-off between true and false warning issues. A ratio between the disadvantages of false positive and false negatives, not greater than one, is introduced in the function. The effect of this ratio on the determination of the thresholds is analysed. The proposed method is based on the availability of a continuous rainfall time series. In Italy, continuous rainfall time series are available from the 1920s, but practical difficulties arise for using them, as they are not published in the Hydrological Annual Reports, by the Servizio Idrografico e Mareografico Nazionale (National Hydrologic and Oceanographic Service), the manager of the most important rainfall monitoring network in Italy. However, it is possible to have a good approximation of the most intense rainfall events, in terms total rainfall, by using the data of annual maxima of precipitation for given durations, which are available in those Reports. The National Research Council's AVI database, the most complete systematic inventory of landslides events occurred in the past century in Italy, can be exploited to determine the thresholds. Hence the method has applicability for whole Italy, and uses large datasets of easy availability. As the method is based on the analysis of subdaily data, it is reliable for shallow landslides, for which low influence of antecedent precipitation on landslide triggering can be supposed. The method is illustrated through its application to case study areas in Sicily, for which there is high interest for activating early warning systems, after that the 1st October 2009 debris flow caused the loss of 37 lives and severe damage to nearby urban areas in the Peloritan Mountains.
False Broomrape: A Physiological Disorder Caused by Growth-Regulator Imbalance 1
Hamilton, James L.; Lowe, Richie H.; Skoog, Folke
1972-01-01
False broomrape on tobacco (Nicotiana tabacum) can be induced by applying cytokinins to the roots, by causing an increase in the cytokinin-auxin ratio in the roots, by removing the apical and auxillary buds, or by applying extracts from tobacco with false broomrape to the roots of healthy plants. It can be prevented by treating debudded plants with auxin. Images PMID:16658161
Statistics provide guidance for indigenous organic carbon detection on Mars missions.
Sephton, Mark A; Carter, Jonathan N
2014-08-01
Data from the Viking and Mars Science Laboratory missions indicate the presence of organic compounds that are not definitively martian in origin. Both contamination and confounding mineralogies have been suggested as alternatives to indigenous organic carbon. Intuitive thought suggests that we are repeatedly obtaining data that confirms the same level of uncertainty. Bayesian statistics may suggest otherwise. If an organic detection method has a true positive to false positive ratio greater than one, then repeated organic matter detection progressively increases the probability of indigeneity. Bayesian statistics also reveal that methods with higher ratios of true positives to false positives give higher overall probabilities and that detection of organic matter in a sample with a higher prior probability of indigenous organic carbon produces greater confidence. Bayesian statistics, therefore, provide guidance for the planning and operation of organic carbon detection activities on Mars. Suggestions for future organic carbon detection missions and instruments are as follows: (i) On Earth, instruments should be tested with analog samples of known organic content to determine their true positive to false positive ratios. (ii) On the mission, for an instrument with a true positive to false positive ratio above one, it should be recognized that each positive detection of organic carbon will result in a progressive increase in the probability of indigenous organic carbon being present; repeated measurements, therefore, can overcome some of the deficiencies of a less-than-definitive test. (iii) For a fixed number of analyses, the highest true positive to false positive ratio method or instrument will provide the greatest probability that indigenous organic carbon is present. (iv) On Mars, analyses should concentrate on samples with highest prior probability of indigenous organic carbon; intuitive desires to contrast samples of high prior probability and low prior probability of indigenous organic carbon should be resisted.
Positive events protect children from causal false memories for scripted events.
Melinder, Annika; Toffalini, Enrico; Geccherle, Eleonora; Cornoldi, Cesare
2017-11-01
Adults produce fewer inferential false memories for scripted events when their conclusions are emotionally charged than when they are neutral, but it is not clear whether the same effect is also found in children. In the present study, we examined this issue in a sample of 132 children aged 6-12 years (mean 9 years, 3 months). Participants encoded photographs depicting six script-like events that had a positively, negatively, or a neutral valenced ending. Subsequently, true and false recognition memory of photographs related to the observed scripts was tested as a function of emotionality. Causal errors-a type of false memory thought to stem from inferential processes-were found to be affected by valence: children made fewer causal errors for positive than for neutral or negative events. Hypotheses are proposed on why adults were found protected against inferential false memories not only by positive (as for children) but also by negative endings when administered similar versions of the same paradigm.
McCoy, Gary R; Touzet, Nicolas; Fleming, Gerard T A; Raine, Robin
2015-07-01
The toxic microalgal species Prymnesium parvum and Prymnesium polylepis are responsible for numerous fish kills causing economic stress on the aquaculture industry and, through the consumption of contaminated shellfish, can potentially impact on human health. Monitoring of toxic phytoplankton is traditionally carried out by light microscopy. However, molecular methods of identification and quantification are becoming more common place. This study documents the optimisation of the novel Microarrays for the Detection of Toxic Algae (MIDTAL) microarray from its initial stages to the final commercial version now available from Microbia Environnement (France). Existing oligonucleotide probes used in whole-cell fluorescent in situ hybridisation (FISH) for Prymnesium species from higher group probes to species-level probes were adapted and tested on the first-generation microarray. The combination and interaction of numerous other probes specific for a whole range of phytoplankton taxa also spotted on the chip surface caused high cross reactivity, resulting in false-positive results on the microarray. The probe sequences were extended for the subsequent second-generation microarray, and further adaptations of the hybridisation protocol and incubation temperatures significantly reduced false-positive readings from the first to the second-generation chip, thereby increasing the specificity of the MIDTAL microarray. Additional refinement of the subsequent third-generation microarray protocols with the addition of a poly-T amino linker to the 5' end of each probe further enhanced the microarray performance but also highlighted the importance of optimising RNA labelling efficiency when testing with natural seawater samples from Killary Harbour, Ireland.
An Improved Extended-Spectrum-β-Lactamase Detection Test Utilizing Aztreonam plus Clavulanate.
Thomson, Gina K; Ayaz, Maaz; Lutes, Kelli; Thomson, Kenneth S
2018-01-01
Clinical laboratories test for extended-spectrum β-lactamases (ESBLs) for epidemiological and infection control purposes and also for the potential of cephalosporins to cause therapeutic failures. Testing can be problematic, because the CLSI does not recommend the testing of all producers of ESBLs and also falsely negative results may occur with isolates that coproduce AmpC. Boronic acid-supplemented tests can enhance ESBL detection in AmpC producers. Because aztreonam inhibits AmpCs, a study was designed to compare ESBL detection by the CLSI disk test (CLSI), a boronic acid-supplemented CLSI disk test (CLSI plus BA), and an aztreonam plus clavulanate disk test (ATM plus CA). The study tested 100 well-characterized Enterobacteriaceae , Acinetobacter baumannii , and Pseudomonas aeruginosa isolates. Seventy produced TEM, SHV, or CTX-M ESBLs, with 15 coproducing an AmpC and 11 coproducing a metallo-β-lactamase. Thirty ESBL-negative isolates were also tested. Tests were inoculated by CLSI methodology and interpreted as positive if an inhibitor caused a zone diameter increase of ≥5 mm. The percentages of ESBL producers detected were as follows: ATM plus CA, 95.7%; CLSI plus BA, 88.6%; and CLSI, 78.6%. When AmpC was coproduced, the sensitivities of the tests were as follows: ATM plus CA, 100%; CLSI plus BA, 93.3%; and CLSI, 60%. ATM plus CA also detected an ESBL in 90.1% of isolates that coproduced a metallo-β-lactamase. Falsely positive tests occurred only with the CLSI and CLSI plus BA tests. Overall, the ATM plus CA test detected ESBLs more accurately than the CLSI and CLSI plus BA tests, especially with isolates coproducing an AmpC or metallo-β-lactamase. Copyright © 2017 American Society for Microbiology.
Strickland, Erin C; Geer, M Ariel; Hong, Jiyong; Fitzgerald, Michael C
2014-01-01
Detection and quantitation of protein-ligand binding interactions is important in many areas of biological research. Stability of proteins from rates of oxidation (SPROX) is an energetics-based technique for identifying the proteins targets of ligands in complex biological mixtures. Knowing the false-positive rate of protein target discovery in proteome-wide SPROX experiments is important for the correct interpretation of results. Reported here are the results of a control SPROX experiment in which chemical denaturation data is obtained on the proteins in two samples that originated from the same yeast lysate, as would be done in a typical SPROX experiment except that one sample would be spiked with the test ligand. False-positive rates of 1.2-2.2% and <0.8% are calculated for SPROX experiments using Q-TOF and Orbitrap mass spectrometer systems, respectively. Our results indicate that the false-positive rate is largely determined by random errors associated with the mass spectral analysis of the isobaric mass tag (e.g., iTRAQ®) reporter ions used for peptide quantitation. Our results also suggest that technical replicates can be used to effectively eliminate such false positives that result from this random error, as is demonstrated in a SPROX experiment to identify yeast protein targets of the drug, manassantin A. The impact of ion purity in the tandem mass spectral analyses and of background oxidation on the false-positive rate of protein target discovery using SPROX is also discussed.
Larrabee, Glenn J
2014-01-01
Bilder, Sugar, and Hellemann (2014 this issue) contend that empirical support is lacking for use of multiple performance validity tests (PVTs) in evaluation of the individual case, differing from the conclusions of Davis and Millis (2014), and Larrabee (2014), who found no substantial increase in false positive rates using a criterion of failure of ≥ 2 PVTs and/or Symptom Validity Tests (SVTs) out of multiple tests administered. Reconsideration of data presented in Larrabee (2014) supports a criterion of ≥ 2 out of up to 7 PVTs/SVTs, as keeping false positive rates close to and in most cases below 10% in cases with bona fide neurologic, psychiatric, and developmental disorders. Strategies to minimize risk of false positive error are discussed, including (1) adjusting individual PVT cutoffs or criterion for number of PVTs failed, for examinees who have clinical histories placing them at risk for false positive identification (e.g., severe TBI, schizophrenia), (2) using the history of the individual case to rule out conditions known to result in false positive errors, (3) using normal performance in domains mimicked by PVTs to show that sufficient native ability exists for valid performance on the PVT(s) that have been failed, and (4) recognizing that as the number of PVTs/SVTs failed increases, the likelihood of valid clinical presentation decreases, with a corresponding increase in the likelihood of invalid test performance and symptom report.
An Evaluation of Unit and ½ Mass Correction Approaches as a ...
Rare earth elements (REE) and certain alkaline earths can produce M+2 interferences in ICP-MS because they have sufficiently low second ionization energies. Four REEs (150Sm, 150Nd, 156Gd and 156Dy) produce false positives on 75As and 78Se and 132Ba can produce a false positive on 66Zn. Currently, US EPA Method 200.8 does not address these as sources of false positives. Additionally, these M+2 false positives are typically enhanced if collision cell technology is utilized to reduce polyatomic interferences associated with ICP-MS detection. A preliminary evaluation indicates that instrumental tuning conditions can impact the observed M+2/M+1 ratio and in turn the false positives generated on Zn, As and Se. Both unit and ½ mass approaches will be evaluated to correct for these false positives relative to the benchmark concentrations estimates from a triple quadrupole ICP-MS using standard solutions. The impact of matrix on these M+2 corrections will be evaluated over multiple analysis days with a focus on evaluating internal standards that mirror the matrix induced shifts in the M+2 ion transmission. The goal of this evaluation is to move away from fixed M+2 corrective approaches and move towards sample specific approaches that mimic the sample matrix induced variability while attempting to address intra-day variability of the M+2 correction factors through the use of internal standards. Oral Presentation via webinar for EPA Laboratory Technical Informati
Kozycki, Christina T; Umulisa, Noella; Rulisa, Stephen; Mwikarago, Emil I; Musabyimana, Jean Pierre; Habimana, Jean Pierre; Karema, Corine; Krogstad, Donald J
2017-03-20
Rapid diagnostic tests (RDTs) for histidine rich protein 2 (HRP2) are often used to determine whether persons with fever should be treated with anti-malarials. However, Plasmodium falciparum parasites with a deletion of the hrp2 gene yield false-negative RDTs and there are concerns the sensitivity of HRP2-based RDTs may fall when the intensity of transmission decreases. This observational study enrolled 9226 patients at three health centres in Rwanda from April 2014 to April 2015. It then compared the sensitivity of RDTs based on HRP2 and the Plasmodium lactate dehydrogenase (pLDH) to microscopy (thick smears) for the diagnosis of malaria. PCR was used to determine whether deletions of the histidine-rich central repeat region of the hrp2 gene (exon 2) were associated with false-negative HRP2-based RDTs. In comparison to microscopy, the sensitivity and specificity of HRP2- and pLDH-based RDTs were 89.5 and 86.2% and 80.2 and 94.3%, respectively. When the results for both RDTs were combined, sensitivity rose to 91.8% and specificity was 85.7%. Additionally, when smear positivity fell from 46 to 3%, the sensitivity of the HRP2-based RDT fell from 88 to 67%. Of 370 samples with false-negative HRP2 RDT results for which PCR was performed, 140 (38%) were identified as P. falciparum by PCR. Of the isolates identified as P. falciparum by PCR, 32 (23%) were negative for the hrp2 gene based on PCR. Of the 32 P. falciparum isolates negative for hrp2 by PCR, 17 (53%) were positive based on the pLDH RDT. This prospective study of RDT performance coincided with a decline in the intensity of malaria transmission in Kibirizi (fall in slide positivity from 46 to 3%). This decline was associated with a decrease in HRP2 RDT sensitivity (from 88 to 67%). While P. falciparum isolates without the hrp2 gene were an important cause of false-negative HRP2-based RDTs, most were identified by the pLDH-based RDT. Although WHO does not recommend the use of combined HRP2/pLDH testing in sub-Saharan Africa, these results suggest that combination HRP2/pLDH-based RDTs could reduce the impact of false-negative HRP2-based RDTs for detection of symptomatic P. falciparum malaria.
Kepler False Positive Rate & Occurrence of Earth-size and Larger Planets
NASA Astrophysics Data System (ADS)
Fressin, Francois; Torres, G.; Charbonneau, D.; Kepler Team
2013-01-01
We model the Kepler exoplanet survey targets and their background stars to estimate the occurrence of astrophysical configurations which could mimic an exoplanetary transit. Using real noise level estimates, we compute the number and the characteristics of detectable eclipsing pairs involving stars or planets. We select the fraction of those that would pass the Kepler candidate vetting procedure, including the modeling of the centroid shift of their position on the Kepler camera. By comparing their distribution with that of the Kepler Object Interests from the first 6 quarters of Kepler data, we quantify the false positive rate of Kepler, as a function of candidate planet size and period. Most importantly, this approach allows quantifying and characterizing the distribution of planets, with no assumption of any prior, as the remaining population of the Kepler candidate list minus the simulated population of alternate astrophysical causes. We study the actual detection recovery rate for Kepler that allows reproducing both the KOI size and period distribution as well as their SNR distribution. We estimate the occurrence of planets down to Earth-size, and study if their frequency is correlated with their host star spectral type. This work is supported by the Spitzer General Observer Proposal #80117 - Validating the First Habitable-Zone Planet Candidates Identified by the NASA Kepler Mission, and by the Kepler Participating Scientist Contract led by David Charbonneau, to confirm the planetary nature of candidates identified by the Kepler mission
Speich, Benjamin; Ali, Said M; Ame, Shaali M; Albonico, Marco; Utzinger, Jürg; Keiser, Jennifer
2015-02-05
An accurate diagnosis of soil-transmitted helminthiasis is important for individual patient management, for drug efficacy evaluation and for monitoring control programmes. The Kato-Katz technique is the most widely used method detecting soil-transmitted helminth eggs in faecal samples. However, detailed analyses of quality control, including false-positive and faecal egg count (FEC) estimates, have received little attention. Over a 3-year period, within the frame of a series of randomised controlled trials conducted in Pemba, United Republic of Tanzania, 10% of randomly selected Kato-Katz thick smears were re-read for Trichuris trichiura and Ascaris lumbricoides eggs. In case of discordant result (i.e. positive versus negative) the slides were re-examined a third time. A result was assumed to be false-positive or false-negative if the result from the initial reading did not agree with the quality control as well as the third reading. We also evaluated the general agreement in FECs between the first and second reading, according to internal and World Health Organization (WHO) guidelines. From the 1,445 Kato-Katz thick smears subjected to quality control, 1,181 (81.7%) were positive for T. trichiura and 290 (20.1%) were positive for A. lumbricoides. During quality control, very low rates of false-positive results were observed; 0.35% (n = 5) for T. trichiura and 0.28% (n = 4) for A. lumbricoides. False-negative readings of Kato-Katz thick smears were obtained in 28 (1.94%) and 6 (0.42%) instances for T. trichiura and A. lumbricoides, respectively. A high frequency of discordant results in FECs was observed (i.e. 10.0-23.9% for T. trichiura, and 9.0-11.4% for A. lumbricoides). Our analyses show that the rate of false-positive diagnoses of soil-transmitted helminths is low. As the probability of false-positive results increases after examination of multiple stool samples from a single individual, the potential influence of false-positive results on epidemiological studies and anthelminthic drug efficacy studies should be determined. Existing WHO guidelines for quality control might be overambitious and might have to be revised, specifically with regard to handling disagreements in FECs.
Can weak crust explain the correlation of geoid and topography on Venus?
NASA Technical Reports Server (NTRS)
Buck, W. Roger
1993-01-01
The effect on geoid and topography of low viscosity crust overlying a steady-state convecting mantle is estimated under the assumption that the shear between crust and mantle does not alter the mantle flow. The weak crustal layer can change the sign of the geoid to topography ratio (admittance). The positive long wavelength admittance for Venus is consistent with a weak crust overlying a mantle with a viscosity that increases strongly with depth. The accepted interpretation of the strong positive correlation of geoid and topography on Venus, is that the convecting mantle of Venus has a constant viscosity with depth. Topography results from vertical normal stresses caused by mantle convection and highlands occur where mantle upwells. For topography to be supported by normal stress, the time scale for crustal flow must be long compared to the time scale for changes in the pattern of mantle flow. Because the high surface temperature of Venus may cause the crust to have a low viscosity, this assumption may be false. Topography should then be dominated by shear coupling between the crust and mantle. In the absence of a crustal layer, convection in a constant viscosity layer gives rise to a geoid anomaly that correlates positively with surface topography. When the viscosity in the layer increases with depth by several orders of magnitude, the surface topography and geoid anomaly become anti-correlated.
A New Way to Confirm Planet Candidates
NASA Astrophysics Data System (ADS)
Kohler, Susanna
2016-05-01
What was the big deal behind the Kepler news conference yesterday? Its not just that the number of confirmed planets found by Kepler has more than doubled (though thats certainly exciting news!). Whats especially interesting is the way in which these new planets were confirmed.Number of planet discoveries by year since 1995, including previous non-Kepler discoveries (blue), previous Kepler discoveries (light blue) and the newly validated Kepler planets (orange). [NASA Ames/W. Stenzel; Princeton University/T. Morton]No Need for Follow-UpBefore Kepler, the way we confirmed planet candidates was with follow-up observations. The candidate could be validated either by directly imaging (which is rare) or obtaining a large number radial-velocity measurements of the wobble of the planets host star due to the planets orbit. But once Kepler started producing planet candidates, these approaches to validation became less feasible. A lot of Kepler candidates are small and orbit faint stars, making follow-up observations difficult or impossible.This problem is what inspired the development of whats known as probabilistic validation, an analysis technique that involves assessing the likelihood that the candidates signal is caused by various false-positive scenarios. Using this technique allows astronomers to estimate the likelihood of a candidate signal being a true planet detection; if that likelihood is high enough, the planet candidate can be confirmed without the need for follow-up observations.A breakdown of the catalog of Kepler Objects of Interest. Just over half had previously been identified as false positives or confirmed as candidates. 1284 are newly validated, and another 455 have FPP of1090%. [Morton et al. 2016]Probabilistic validation has been used in the past to confirm individual planet candidates in Kepler data, but now Timothy Morton (Princeton University) and collaborators have taken this to a new level: they developed the first code thats designed to do fully automated batch processing of a large number of candidates.In a recently published study the results of which were announced yesterday the teamapplied their code to the entire catalog of 7,470 Kepler objects of interest.New Planets and False PositivesThe teams code was able to successfully evaluate the total false-positive probability (FPP) for 7,056 of the objects of interest. Of these, 428 objects previously identified as candidates were found to have FPP of more than 90%, suggesting that they are most likely false positives.Periods and radii of candidate and confirmed planets in the Kepler Objects of Interest catalog. Blue circles have previously been identified as confirmed planets. Candidates (orange) are shaded by false positive probability; more transparent means more likely to be a false positive. [Morton et al. 2016]In contrast, 1,935 candidates were found to have FPP of less than 1%, and were therefore declared validated planets. Of these confirmations, 1,284 were previously unconfirmed, more than doubling Keplers previous catalog of 1,041 confirmed planets. Morton and collaborators believe that 9 of these newly confirmed planets may fall within the habitable zone of their host stars.While the announcement of 1,284 newly confirmed planets is huge, the analysis presented in this study is the real news. The code used is publicly available and can be applied to any transiting exoplanet candidate. This means that this analysis technique can be used to find batches of exoplanets in data from the extended Kepler mission (K2) or from the future TESS and PLATO transit missions.CitationTimothy D. Morton et al 2016 ApJ 822 86. doi:10.3847/0004-637X/822/2/86
Nandipati, Kalyana C; Allamaneni, Shyam; Kakarla, Ravindra; Wong, Alfredo; Richards, Neil; Satterfield, James; Turner, James W; Sung, Kae-Jae
2011-05-01
Early identification of pneumothorax is crucial to reduce the mortality in critically injured patients. The objective of our study is to investigate the utility of surgeon performed extended focused assessment with sonography for trauma (EFAST) in the diagnosis of pneumothorax. We prospectively analysed 204 trauma patients in our level I trauma center over a period of 12 (06/2007-05/2008) months in whom EFAST was performed. The patients' demographics, type of injury, clinical examination findings (decreased air entry), CXR, EFAST and CT scan findings were entered into the data base. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated. Of 204 patients (mean age--43.01+/-19.5 years, sex--male 152, female 52) 21 (10.3%) patients had pneumothorax. Of 21 patients who had pneumothorax 12 were due to blunt trauma and 9 were due to penetrating trauma. The diagnosis of pneumothorax in 204 patients demonstrated the following: clinical examination was positive in 17 patients (true positive in 13/21, 62%; 4 were false positive and 8 were false negative), CXR was positive in 16 (true positive in 15/19, 79%; 1 false positive, 4 missed and 2 CXR not performed before chest tube) patients and EFAST was positive in 21 patients (20 were true positive [95.2%], 1 false positive and 1 false negative). In diagnosing pneumothorax EFAST has significantly higher sensitivity compared to the CXR (P=0.02). Surgeon performed trauma room extended FAST is simple and has higher sensitivity compared to the chest X-ray and clinical examination in detecting pneumothorax. Published by Elsevier Ltd.
1984-01-01
The Research Committee of the British Thoracic Association conducted a confidential inquiry into death from asthma in adults aged 15-64 years resident in the West Midland and Mersey Regions during 1979. Death certificates recording the word asthma were received for 153 persons. The International Classification of Diseases code for the cause of death was obtained from the Office of Population Censuses and Surveys. Information about the patients, their illness, and their death was obtained by interviews, questionnaires, and inspection of patients' records. A panel of three physicians assisted by a pathologist assessed the clinical and, where applicable, the necropsy findings to ascertain whether bronchial asthma was the true cause of death. Of 147 assessable patients, 89 were considered by the panel to have died from asthma. In 77 of these cases the death certificates were correctly coded, whereas in 12 (13%) death was considered to have been wrongly attributed to another cause (falsely negative). Twenty four deaths on the other hand were considered to have been wrongly attributed to asthma (falsely positive). From this it appears that the total number of 101 certificates recording death from asthma represents a net overestimate of 13%. Accuracy was highest in the youngest age group. There were few discrepancies between the assessment of the panel and certified cause of death when a necropsy had been performed. The most common error (17% of all certificates) was failure to follow the procedure advised for completion of death certificates. This usually occurred when patients suffered from two or more conditions, or when death was sudden and necropsy was not performed. PMID:6463930
1984-07-01
The Research Committee of the British Thoracic Association conducted a confidential inquiry into death from asthma in adults aged 15-64 years resident in the West Midland and Mersey Regions during 1979. Death certificates recording the word asthma were received for 153 persons. The International Classification of Diseases code for the cause of death was obtained from the Office of Population Censuses and Surveys. Information about the patients, their illness, and their death was obtained by interviews, questionnaires, and inspection of patients' records. A panel of three physicians assisted by a pathologist assessed the clinical and, where applicable, the necropsy findings to ascertain whether bronchial asthma was the true cause of death. Of 147 assessable patients, 89 were considered by the panel to have died from asthma. In 77 of these cases the death certificates were correctly coded, whereas in 12 (13%) death was considered to have been wrongly attributed to another cause (falsely negative). Twenty four deaths on the other hand were considered to have been wrongly attributed to asthma (falsely positive). From this it appears that the total number of 101 certificates recording death from asthma represents a net overestimate of 13%. Accuracy was highest in the youngest age group. There were few discrepancies between the assessment of the panel and certified cause of death when a necropsy had been performed. The most common error (17% of all certificates) was failure to follow the procedure advised for completion of death certificates. This usually occurred when patients suffered from two or more conditions, or when death was sudden and necropsy was not performed.
When good news is bad news: psychological impact of false positive diagnosis of HIV.
Bhattacharya, Rahul; Barton, Simon; Catalan, Jose
2008-05-01
HIV testing is known to be stressful, however the impact of false positive HIV results on individuals is not well documented. This is a series of four case who developed psychological difficulties and psychiatric morbidities after being informed they had been misdiagnosed with HIV-positive status. We look into documented cases of misdiagnosis and potential risks of misdiagnosis. The case series highlights the implications a false diagnosis HIV-positive status can have, even when the diagnosis is rectified. Impact of misdiagnosis of HIV can lead to psychosocial difficulties and psychiatric morbidity, have public health and epidemiological implications and can lead to medico-legal conflict. This further reiterates the importance of HIV testing carried out ethically and sensitively, and in line with guidelines, respecting confidentiality and consent, and offering counselling pre-test and post-test, being mindful of the reality of erroneous and false positive HIV test results. The implications of misdiagnosis are for the individual, their partners and social contacts, as well as for the community.
Comparing diagnostic tests on benefit-risk.
Pennello, Gene; Pantoja-Galicia, Norberto; Evans, Scott
2016-01-01
Comparing diagnostic tests on accuracy alone can be inconclusive. For example, a test may have better sensitivity than another test yet worse specificity. Comparing tests on benefit risk may be more conclusive because clinical consequences of diagnostic error are considered. For benefit-risk evaluation, we propose diagnostic yield, the expected distribution of subjects with true positive, false positive, true negative, and false negative test results in a hypothetical population. We construct a table of diagnostic yield that includes the number of false positive subjects experiencing adverse consequences from unnecessary work-up. We then develop a decision theory for evaluating tests. The theory provides additional interpretation to quantities in the diagnostic yield table. It also indicates that the expected utility of a test relative to a perfect test is a weighted accuracy measure, the average of sensitivity and specificity weighted for prevalence and relative importance of false positive and false negative testing errors, also interpretable as the cost-benefit ratio of treating non-diseased and diseased subjects. We propose plots of diagnostic yield, weighted accuracy, and relative net benefit of tests as functions of prevalence or cost-benefit ratio. Concepts are illustrated with hypothetical screening tests for colorectal cancer with test positive subjects being referred to colonoscopy.
Gas insufflation of minimal preparation CT of the colon reduces false-positives
Slater, A; North, M; Hart, M; Ferrett, C
2012-01-01
Objectives Minimal preparation CT of the colon (MPCT colon) is used for investigation of suspected colorectal cancer in frail and/or elderly patients who would be expected to tolerate laxative bowel preparation poorly. Although it has good sensitivity for colorectal cancer it has a poor specificity. We wished to investigate whether distension of the colon with carbon dioxide alone would reduce the number of false-positives, but without making the test arduous or excessively uncomfortable. Methods 134 patients were recruited and underwent MPCT colon with gas insufflation and antispasmodics. Results were compared with a cohort of 134 patients undergoing standard protocol MPCT colon. The numbers of false-positives were compared, as was reader confidence. All trial patients were given a questionnaire documenting their experience. Results The number of false-positives was 15% in the control group and 5% in the trial group; this difference was statistically significant, (p=0.01). Reader confidence was increased in the trial group. Patient tolerance was good, with 95% saying they would have the test again. Conclusion Use of gas insufflation and antispasmodics reduces the false-positives from 15% to 5% without adversely affecting patient tolerance. PMID:21224295
False memories, but not false beliefs, affect implicit attitudes for food preferences.
Howe, David; Anderson, Rachel J; Dewhurst, Stephen A
2017-09-01
Previous studies have found that false memories and false beliefs of childhood experiences can have attitudinal consequences. Previous studies have, however, focused exclusively on explicit attitude measures without exploring whether implicit attitudes are similarly affected. Using a false feedback/imagination inflation paradigm, false memories and beliefs of enjoying a certain food as a child were elicited in participants, and their effects were assessed using both explicit attitude measures (self-report questionnaires) and implicit measures (a Single-Target Implicit Association Test). Positive changes in explicit attitudes were observed both in participants with false memories and participants with false beliefs. In contrast, only participants with false memories exhibited more positive implicit attitudes. The findings are discussed in terms of theories of explicit and implicit attitudes. Copyright © 2017 Elsevier B.V. All rights reserved.
[Streptococcal pharyngitis: clinical suspicion versus diagnosis].
Morais, Sofia; Teles, Andreia; Ramalheira, Elmano; Roseta, José
2009-01-01
Pharyngitis is a very prevalent illness in the ambulatory care setting. Its diagnosis is a challenge, especially in the differentiation between the viric and streptococcal causes. A formulary was made to register the clinical and laboratory data; a throat swab for culture was obtained from all the children who presented to the emergency department with sore throat and/or signs of pharyngitis/tonsillitis, for a period of three months (15th of April to 15th of July of 2006). The signs and symptoms, prescribed antibiotherapy and frequency of false diagnostics were evaluated and the clinical suspicion compared with the diagnosis by culture. 158 children were evaluated, with a median age of four years, with a male predominance (56%). The period that showed the greatest number of cases was the first fifteen days of May. Forty-three percent of the cultures were positive for Streptococcus pyogenes. The more frequent signs and symptoms in pharyngitis were pharyngeal erythema (98%), fever (86%) and sore throat (78%). A significative statistical difference was found for cough, scarlatiniform rash, tonsillar exudate, palatal petechiae and tonsillar swelling. Of the signs and symptoms studied, only three of them presented a positive predictive value superior to 50%: scarlatiniform rash (85%), palatal petechiae (63%) and cough (57%). The presence of tonsillar exudate had a positive predictive value for non-streptococcal pharyngitis of 70%. Fifty-three percent of the doctors considered streptococcal pharyngitis highly probable, and from this, 56% had a positive culture for Streptococcus. Those who considered a low probability, the culture was positive in 28%. There were 37% of false diagnosis. The distinction between streptococcal pharyngitis and non-streptococcal pharyngitis is not always correct when based on clinical characteristics. The use of diagnostic tests is important in order to avoid unnecessary antibiotherapy as well as to allow the correct use in the positive cases.
Simmons, Joseph P; Nelson, Leif D; Simonsohn, Uri
2011-11-01
In this article, we accomplish two things. First, we show that despite empirical psychologists' nominal endorsement of a low rate of false-positive findings (≤ .05), flexibility in data collection, analysis, and reporting dramatically increases actual false-positive rates. In many cases, a researcher is more likely to falsely find evidence that an effect exists than to correctly find evidence that it does not. We present computer simulations and a pair of actual experiments that demonstrate how unacceptably easy it is to accumulate (and report) statistically significant evidence for a false hypothesis. Second, we suggest a simple, low-cost, and straightforwardly effective disclosure-based solution to this problem. The solution involves six concrete requirements for authors and four guidelines for reviewers, all of which impose a minimal burden on the publication process.
Fusion of ultrasonic and infrared signatures for personnel detection by a mobile robot
NASA Astrophysics Data System (ADS)
Carroll, Matthew S.; Meng, Min; Cadwallender, William K.
1992-04-01
Passive Infrared sensors used for intrusion detection, especially those used on mobile robots, are vulnerable to false alarms caused by clutter objects such as radiators, steam pipes, windows, etc., as well as deliberately caused false alarms caused by decoy objects. To overcome these sources of false alarms, we are now combining thermal and ultrasonic signals, the results being a more robust system for detecting personnel. Our paper will discuss the fusion strategies used for combining sensor information. Our first strategy uses a statistical classifier using features such as the sonar cross-section, the received thermal energy, and ultrasonic range. Our second strategy uses s 3-layered neural classifier trained by backpropagation. The probability of correct classification and the false alarm rate for both strategies will be presented in the paper.
Colloff, Melissa F; Flowe, Heather D
2016-06-01
False face recognition rates are sometimes higher when faces are learned while under the influence of alcohol. Alcohol myopia theory (AMT) proposes that acute alcohol intoxication during face learning causes people to attend to only the most salient features of a face, impairing the encoding of less salient facial features. Yet, there is currently no direct evidence to support this claim. Our objective was to test whether acute alcohol intoxication impairs face learning by causing subjects to attend to a salient (i.e., distinctive) facial feature over other facial features, as per AMT. We employed a balanced placebo design (N = 100). Subjects in the alcohol group were dosed to achieve a blood alcohol concentration (BAC) of 0.06 %, whereas the no alcohol group consumed tonic water. Alcohol expectancy was controlled. Subjects studied faces with or without a distinctive feature (e.g., scar, piercing). An old-new recognition test followed. Some of the test faces were "old" (i.e., previously studied), and some were "new" (i.e., not previously studied). We varied whether the new test faces had a previously studied distinctive feature versus other familiar characteristics. Intoxicated and sober recognition accuracy was comparable, but subjects in the alcohol group made more positive identifications overall compared to the no alcohol group. The results are not in keeping with AMT. Rather, a more general cognitive mechanism appears to underlie false face recognition in intoxicated subjects. Specifically, acute alcohol intoxication during face learning results in more liberal choosing, perhaps because of an increased reliance on familiarity.
The Occurrence Rate of Hot Jupiters
NASA Astrophysics Data System (ADS)
Rampalli, Rayna; Catanzarite, Joseph; Batalha, Natalie M.
2017-01-01
As the first kind of exoplanet to be discovered, hot Jupiters have always been objects of interest. Despite being prevalent in radial velocity and ground-based surveys, they were found to be much rarer based on Kepler observations. These data show a pile-up at radii of 9-22 Rearth and orbital periods of 1-10 days. Computing accurate occurrence rates can lend insight into planet-formation and migration-theories. To get a more accurate look, the idea of reliability was introduced. Each hot Jupiter candidate was assigned a reliability based on its location in the galactic plane and likelihood of being a false positive. Numbers were updated if ground-based follow-up indicated a candidate was indeed a false positive. These reliabilities were introduced into an occurrence rate calculation and yielded about a 12% decrease in occurrence rate for each period bin examined and a 25% decrease across all the bins. To get a better idea of the cause behind the pileup, occurrence rates based on parent stellar metallicity were calculated. As expected from previous work, higher metallicity stars yield higher occurrence rates. Future work includes examining period distributions in both the high metallicity and low metallicity sample for a better understanding and confirmation of the pile-up effect.
Statistical parsimony networks and species assemblages in Cephalotrichid nemerteans (nemertea).
Chen, Haixia; Strand, Malin; Norenburg, Jon L; Sun, Shichun; Kajihara, Hiroshi; Chernyshev, Alexey V; Maslakova, Svetlana A; Sundberg, Per
2010-09-21
It has been suggested that statistical parsimony network analysis could be used to get an indication of species represented in a set of nucleotide data, and the approach has been used to discuss species boundaries in some taxa. Based on 635 base pairs of the mitochondrial protein-coding gene cytochrome c oxidase I (COI), we analyzed 152 nemertean specimens using statistical parsimony network analysis with the connection probability set to 95%. The analysis revealed 15 distinct networks together with seven singletons. Statistical parsimony yielded three networks supporting the species status of Cephalothrix rufifrons, C. major and C. spiralis as they currently have been delineated by morphological characters and geographical location. Many other networks contained haplotypes from nearby geographical locations. Cladistic structure by maximum likelihood analysis overall supported the network analysis, but indicated a false positive result where subnetworks should have been connected into one network/species. This probably is caused by undersampling of the intraspecific haplotype diversity. Statistical parsimony network analysis provides a rapid and useful tool for detecting possible undescribed/cryptic species among cephalotrichid nemerteans based on COI gene. It should be combined with phylogenetic analysis to get indications of false positive results, i.e., subnetworks that would have been connected with more extensive haplotype sampling.
Douville, Christopher; Masica, David L; Stenson, Peter D; Cooper, David N; Gygax, Derek M; Kim, Rick; Ryan, Michael; Karchin, Rachel
2016-01-01
Insertion/deletion variants (indels) alter protein sequence and length, yet are highly prevalent in healthy populations, presenting a challenge to bioinformatics classifiers. Commonly used features--DNA and protein sequence conservation, indel length, and occurrence in repeat regions--are useful for inference of protein damage. However, these features can cause false positives when predicting the impact of indels on disease. Existing methods for indel classification suffer from low specificities, severely limiting clinical utility. Here, we further develop our variant effect scoring tool (VEST) to include the classification of in-frame and frameshift indels (VEST-indel) as pathogenic or benign. We apply 24 features, including a new "PubMed" feature, to estimate a gene's importance in human disease. When compared with four existing indel classifiers, our method achieves a drastically reduced false-positive rate, improving specificity by as much as 90%. This approach of estimating gene importance might be generally applicable to missense and other bioinformatics pathogenicity predictors, which often fail to achieve high specificity. Finally, we tested all possible meta-predictors that can be obtained from combining the four different indel classifiers using Boolean conjunctions and disjunctions, and derived a meta-predictor with improved performance over any individual method. © 2015 The Authors. **Human Mutation published by Wiley Periodicals, Inc.
Redshaw, Natalie; Dickson, Stuart J; Ambrose, Vikki; Horswell, Jacqui
2007-10-25
The bioluminescence response of two genetically modified (lux-marked) bacteria to potentially toxic compounds (PTCs) in stomach contents was monitored using an in vitro assay. Cells of Escherichia coli HB101 and Salmonella typhimurium both carrying the lux light producing gene on a plasmid (pUDC607) were added to stomach contents containing various concentrations of organic and inorganic compounds. There was some variability in the response of the two biosensors, but both were sensitive to the herbicides glyphosate, 2,4-dichlorophenoxyacetic acid (2,4-D), 2,4,5-trichlorophenoxyacetic acid (2,4,5-T); pentachlorophenol (PCP), and inorganic poisons arsenic and mercury at a concentration range likely to be found in stomach contents samples submitted for toxicological analysis. This study demonstrates that biosensor bioassays could be a useful preliminary screening tool in forensic toxicology and that such a toxicological screening should include more than one test organism to maximise the number of PTC's detected. The probability of false positive results from samples containing compounds that may interfere with the assay such as over-the-counter (OTC) drugs and caffeine in tea and coffee was also investigated. Of the substances tested only coffee has the potential to cause false positive results.
Jaroenram, Wansadaj; Owens, Leigh
2014-11-01
Penaeus stylirostris densovirus (PstDV) is an important shrimp pathogen that causes mortality in P. stylirostris and runt deformity syndrome (RDS) in Penaeus vannamei and Penaeus monodon. Recently, PstDV-related sequences were found in the genome of P. monodon and P. vannamei. This led to false positive results by PCR-based detection system. Here, a more efficient detection platform based on recombinase polymerase amplification (RPA) and a lateral flow dipstick (LFD) was developed for detecting PstDV. Under the optimal conditions, 30 min at 37°C for RPA followed by 5 min at room temperature for LFD, the protocol was 10 times more sensitive than the Saksmerphrome et al's interim 3-tube nested PCR and showed no cross-reaction with other shrimp viruses. It also reduced false positive results arising from viral inserts to ∼5% compared to 76-78% by the IQ2000™ nested PCR kit and the 309F/R PCR protocol currently recommended by World Organization for Animal Health (OIE) for PstDV detection. Together with simplicity and portability, the protocol serves as an alternative tool to PCR for primarily screening PstDV, which is suitable for both laboratory and field application. Copyright © 2014 Elsevier B.V. All rights reserved.
Risk of Breast Cancer in Women with False-Positive Results according to Mammographic Features.
Castells, Xavier; Torá-Rocamora, Isabel; Posso, Margarita; Román, Marta; Vernet-Tomas, Maria; Rodríguez-Arana, Ana; Domingo, Laia; Vidal, Carmen; Baré, Marisa; Ferrer, Joana; Quintana, María Jesús; Sánchez, Mar; Natal, Carmen; Espinàs, Josep A; Saladié, Francina; Sala, María
2016-08-01
Purpose To assess the risk of breast cancer in women with false-positive screening results according to radiologic classification of mammographic features. Materials and Methods Review board approval was obtained, with waiver of informed consent. This retrospective cohort study included 521 200 women aged 50-69 years who underwent screening as part of the Spanish Breast Cancer Screening Program between 1994 and 2010 and who were observed until December 2012. Cox proportional hazards regression analysis was used to estimate the age-adjusted hazard ratio (HR) of breast cancer and the 95% confidence interval (CI) in women with false-positive mammograms as compared with women with negative mammograms. Separate models were adjusted for screen-detected and interval cancers and for screen-film and digital mammography. Time without a breast cancer diagnosis was plotted by using Kaplan-Meier curves. Results When compared with women with negative mammograms, the age-adjusted HR of cancer in women with false-positive results was 1.84 (95% CI: 1.73, 1.95; P < .001). The risk was higher in women who had calcifications, whether they were (HR, 2.73; 95% CI: 2.28, 3.28; P < .001) or were not (HR, 2.24; 95% CI: 2.02, 2.48; P < .001) associated with masses. Women in whom mammographic features showed changes in subsequent false-positive results were those who had the highest risk (HR, 9.13; 95% CI: 8.28, 10.07; P < .001). Conclusion Women with false-positive results had an increased risk of breast cancer, particularly women who had calcifications at mammography. Women who had more than one examination with false-positive findings and in whom the mammographic features changed over time had a highly increased risk of breast cancer. Previous mammographic features might yield useful information for further risk-prediction models and personalized follow-up screening protocols. (©) RSNA, 2016 Online supplemental material is available for this article.
Real-time Bayesian anomaly detection in streaming environmental data
NASA Astrophysics Data System (ADS)
Hill, David J.; Minsker, Barbara S.; Amir, Eyal
2009-04-01
With large volumes of data arriving in near real time from environmental sensors, there is a need for automated detection of anomalous data caused by sensor or transmission errors or by infrequent system behaviors. This study develops and evaluates three automated anomaly detection methods using dynamic Bayesian networks (DBNs), which perform fast, incremental evaluation of data as they become available, scale to large quantities of data, and require no a priori information regarding process variables or types of anomalies that may be encountered. This study investigates these methods' abilities to identify anomalies in eight meteorological data streams from Corpus Christi, Texas. The results indicate that DBN-based detectors, using either robust Kalman filtering or Rao-Blackwellized particle filtering, outperform a DBN-based detector using Kalman filtering, with the former having false positive/negative rates of less than 2%. These methods were successful at identifying data anomalies caused by two real events: a sensor failure and a large storm.
Streby, Henry M.; Kramer, Gunnar R.; Peterson, Sean M.; Lehman, Justin A.; Buehler, David A.; Andersen, David
2018-01-01
Lisovski et al. [1] describe the widely recognized limitations of light-level geolocator data for identifying short-distance latitudinal movements, recommend that caution be used when interpreting such data, intimated that we did not use such caution and argued that environmental shading likely explained the Golden-winged Warbler (Vermivora chrysoptera) movements described in our 2015 report [2] . Lisovski et al. [1] conclude that the bird movements we reported could not be disentangled from estimation error in stationary animals caused by environmental shading. We argue that, to the contrary, these hypotheses can easily be disentangled because the premise that environmental shading caused synchronous and parallel error among geolocators is false. With their assertion that our location estimates could be biased by >3,500 km on a day with no observable local sources of shading, Lisovski et al. [1] have taken a position of incredulity toward all geolocator-based animal movement data published to date.
Automatic lung nodule graph cuts segmentation with deep learning false positive reduction
NASA Astrophysics Data System (ADS)
Sun, Wenqing; Huang, Xia; Tseng, Tzu-Liang Bill; Qian, Wei
2017-03-01
To automatic detect lung nodules from CT images, we designed a two stage computer aided detection (CAD) system. The first stage is graph cuts segmentation to identify and segment the nodule candidates, and the second stage is convolutional neural network for false positive reduction. The dataset contains 595 CT cases randomly selected from Lung Image Database Consortium and Image Database Resource Initiative (LIDC/IDRI) and the 305 pulmonary nodules achieved diagnosis consensus by all four experienced radiologists were our detection targets. Consider each slice as an individual sample, 2844 nodules were included in our database. The graph cuts segmentation was conducted in a two-dimension manner, 2733 lung nodule ROIs are successfully identified and segmented. With a false positive reduction by a seven-layer convolutional neural network, 2535 nodules remain detected while the false positive dropped to 31.6%. The average F-measure of segmented lung nodule tissue is 0.8501.
Daxboeck, Florian; Dornbusch, Hans Jürgen; Krause, Robert; Assadian, Ojan; Wenisch, Christoph
2004-01-01
A small but significant proportion of blood cultures processed by the BACTEC 9000 series systems is signaled positive, while subsequent Gram's stain and culture on solid media yield no pathogens. In this study, 15 "false-positive" vials (7 aerobes, 8 anaerobes) from 15 patients were investigated for the presence of bacteria and fungi by eubacterial 16S rDNA and panfungal 18S rDNA amplification, respectively. All samples turned out negative by both methods. Most patients (7) had neutropenia, which does not support the theory that high leukocyte counts enhance the generation of false-positive results. In conclusion, the results of this study indicate that false-negative results generated by the BACTEC 9000 series are inherent to the automated detection and not due to the growth of fastidious organisms.
False positives in psychiatric diagnosis: implications for human freedom.
Wakefield, Jerome C
2010-02-01
Current symptom-based DSM and ICD diagnostic criteria for mental disorders are prone to yielding false positives because they ignore the context of symptoms. This is often seen as a benign flaw because problems of living and emotional suffering, even if not true disorders, may benefit from support and treatment. However, diagnosis of a disorder in our society has many ramifications not only for treatment choice but for broader social reactions to the diagnosed individual. In particular, mental disorders impose a sick role on individuals and place a burden upon them to change; thus, disorders decrease the level of respect and acceptance generally accorded to those with even annoying normal variations in traits and features. Thus, minimizing false positives is important to a pluralistic society. The harmful dysfunction analysis of disorder is used to diagnose the sources of likely false positives, and propose potential remedies to the current weaknesses in the validity of diagnostic criteria.
False positive malaria rapid diagnostic test in returning traveler with typhoid fever.
Meatherall, Bonnie; Preston, Keith; Pillai, Dylan R
2014-07-09
Rapid diagnostic tests play a pivotal role in the early diagnosis of malaria where microscopy or polymerase chain reaction are not immediately available. We report the case of a 39 year old traveler to Canada who presented with fever, headache, and abdominal pain after visiting friends and relatives in India. While in India, the individual was not ill and had no signs or symptoms of malaria. Laboratory testing upon his return to Canada identified a false positive malaria rapid diagnostic (BinaxNOW® malaria) result for P. falciparum with coincident Salmonella Typhi bacteraemia without rheumatoid or autoimmune factors. Rapid diagnostic test false positivity for malaria coincided with the presence or absence of Salmonella Typhi in the blood. Clinicians should be aware that Salmonella Typhi infection may result in a false positive malaria rapid diagnostic test. The mechanism of this cross-reactivity is not clear.
Nissan, Jack; Abrahams, Sharon; Sala, Sergio Della
2013-01-01
It is a common finding in tests of false recognition that amnesic patients recognize fewer related lures than healthy controls, and this has led to assumptions that gist memory is damaged in these patients (Schacter, Verfaellie, & Anes, 1997, Neuropsychology, 11; Schacter, Verfaellie, Anes, & Racine, 1998, Journal of Cognitive Neuroscience, 10; Schacter, Verfaellie, & Pradere, 1996, Journal of Memory and Language, 35). However, clinical observations find that amnesic patients typically hold meaningful conversations and make relevant remarks, and there is some experimental evidence highlighting preserved immediate recall of prose (Baddeley & Wilson, 2002, Neuropsychologia, 40; Gooding, Isaac, & Mayes, 2005, Neuropsychologia, 43; Rosenbaum, Gilboa, Levine, Winocur, & Moscovitch, 2009, Neuropsychologia, 47), which suggests that amnesiacs can get the gist. The present experiment used false recognition paradigms to assess whether the reduced rate of false recognition found in amnesic patients may be a consequence of their impaired item-specific memory. It examined the effect of increasing the item-specific memory of amnesic patient DA by bringing her to criterion on relevant study-lists and compared her performance on a false recognition paradigm with a group of 32 healthy young adults. Results indicated that when DA's item-specific memory was increased she was more able to gist and her performance was no different to the healthy young adults. Previous assumptions that gist memory is necessarily damaged in amnesia might therefore be revisited, since the reduced rate of false recognition could be caused by impaired item-specific memory. The experiment also highlights a positive relationship between item-specific and gist memory which has not previously been accounted for in false-recognition experiments.
E/N effects on K0 values revealed by high precision measurements under low field conditions
NASA Astrophysics Data System (ADS)
Hauck, Brian C.; Siems, William F.; Harden, Charles S.; McHugh, Vincent M.; Hill, Herbert H.
2016-07-01
Ion mobility spectrometry (IMS) is used to detect chemical warfare agents, explosives, and narcotics. While IMS has a low rate of false positives, their occurrence causes the loss of time and money as the alarm is verified. Because numerous variables affect the reduced mobility (K0) of an ion, wide detection windows are required in order to ensure a low false negative response rate. Wide detection windows, however, reduce response selectivity, and interferents with similar K0 values may be mistaken for targeted compounds and trigger a false positive alarm. Detection windows could be narrowed if reference K0 values were accurately known for specific instrumental conditions. Unfortunately, there is a lack of confidence in the literature values due to discrepancies in the reported K0 values and their lack of reported error. This creates the need for the accurate control and measurement of each variable affecting ion mobility, as well as for a central accurate IMS database for reference and calibration. A new ion mobility spectrometer has been built that reduces the error of measurements affecting K0 by an order of magnitude less than ±0.2%. Precise measurements of ±0.002 cm2 V-1 s-1 or better have been produced and, as a result, an unexpected relationship between K0 and the electric field to number density ratio (E/N) has been discovered in which the K0 values of ions decreased as a function of E/N along a second degree polynomial trend line towards an apparent asymptote at approximately 4 Td.
NASA Astrophysics Data System (ADS)
Hirano, Mitsuharu; Tonosaki, Shozo; Ueno, Takahiro; Tanaka, Masato; Hasegawa, Takemi
2014-02-01
We report an improved method to visualize lipid distribution in axial and lateral direction within arterial vessel walls by spectroscopic spectral-domain Optical Coherence Tomography (OCT) at 1.7μm wavelength for identification of lipidrich plaque that is suspected to cause coronary events. In our previous method, an extended InGaAs-based line camera detects an OCT interferometric spectrum from 1607 to 1766 nm, which is then divided into twenty subbands, and A-scan OCT profile is calculated for each subband, resulting in a tomographic spectrum. This tomographic spectrum is decomposed into lipid spectrum having an attenuation peak at 1730 nm and non-lipid spectrum independent of wavelength, and the weight of each spectrum, that is, lipid and non-lipid score is calculated. In this paper, we present an improved algorithm, in which we have combined the lipid score and the non-lipid score to derive a corrected lipid score. We have found that the corrected lipid score is better than the raw lipid score in that the former is more robust against false positive occurring due to abrupt change in reflectivity at vessel surface. In addition, we have optimized spatial smoothing filter and reduced false positive and false negative due to detection noise and speckle. We have verified this improved algorithm by the use of measuring data of normal porcine coronary artery and lard as a model of lipid-rich plaque and confirmed that both the sensitivity and the specificity of lard are 92%.
Cheurfa, N; Giard, S
2015-01-01
Despite the standard management of non-palpable breast cancer (needle core biopsy diagnostic, accurate preoperative localization), there are differences in some cases between the malignant histo-pathological finding in diagnostic biopsy results and negative histo-pathological finding after surgical excision. The aim of this study is to evaluate this incidence and classifying them under three category: failure of surgical excision after preoperative identification; removal of the tumor was already completed by percutaneous biopsy; percutaneous biopsy true false positive. We conducted a study based on prospective database, all patients included in this study had partial mastectomy for ductal carcinoma in-situ or invasive cancer which was diagnosed by needle core biopsy and normal/benign after surgery. Regarding the partial mastectomy, 1863 was performed in the last three years in our center. Thirty-seven patients (2%) correspond our study criteria. After discussion of cases in our multidisciplinary reunion, 6 patients (16%) were considered as failure of surgical excision, 26 patients (70%) as true removal of the whole lesion in the core, and 5 patients (13%) as true false-positive cores. This is the first study witch investigate all factors that influence the results of negative final histo-pathological finding of surgical excision of the tumor after malignant diagnostic needle core biopsy. This rare situation need a multidisciplinary meeting to analyse all the steps of management and to determine causes of those false results and try to find adequate management to solve this problem. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Schlain, Brian; Amaravadi, Lakshmi; Donley, Jean; Wickramasekera, Ananda; Bennett, Donald; Subramanyam, Meena
2010-01-31
In recent years there has been growing recognition of the impact of anti-drug or anti-therapeutic antibodies (ADAs, ATAs) on the pharmacokinetic and pharmacodynamic behavior of the drug, which ultimately affects drug exposure and activity. These anti-drug antibodies can also impact safety of the therapeutic by inducing a range of reactions from hypersensitivity to neutralization of the activity of an endogenous protein. Assessments of immunogenicity, therefore, are critically dependent on the bioanalytical method used to test samples, in which a positive versus negative reactivity is determined by a statistically derived cut point based on the distribution of drug naïve samples. For non-normally distributed data, a novel gamma-fitting method for obtaining assay cut points is presented. Non-normal immunogenicity data distributions, which tend to be unimodal and positively skewed, can often be modeled by 3-parameter gamma fits. Under a gamma regime, gamma based cut points were found to be more accurate (closer to their targeted false positive rates) compared to normal or log-normal methods and more precise (smaller standard errors of cut point estimators) compared with the nonparametric percentile method. Under a gamma regime, normal theory based methods for estimating cut points targeting a 5% false positive rate were found in computer simulation experiments to have, on average, false positive rates ranging from 6.2 to 8.3% (or positive biases between +1.2 and +3.3%) with bias decreasing with the magnitude of the gamma shape parameter. The log-normal fits tended, on average, to underestimate false positive rates with negative biases as large a -2.3% with absolute bias decreasing with the shape parameter. These results were consistent with the well known fact that gamma distributions become less skewed and closer to a normal distribution as their shape parameters increase. Inflated false positive rates, especially in a screening assay, shifts the emphasis to confirm test results in a subsequent test (confirmatory assay). On the other hand, deflated false positive rates in the case of screening immunogenicity assays will not meet the minimum 5% false positive target as proposed in the immunogenicity assay guidance white papers. Copyright 2009 Elsevier B.V. All rights reserved.
Storbeck, Justin
2013-01-01
I investigated whether negative affective states enhance encoding of and memory for item-specific information reducing false memories. Positive, negative, and neutral moods were induced, and participants then completed a Deese-Roediger-McDermott (DRM) false-memory task. List items were presented in unique spatial locations or unique fonts to serve as measures for item-specific encoding. The negative mood conditions had more accurate memories for item-specific information, and they also had fewer false memories. The final experiment used a manipulation that drew attention to distinctive information, which aided learning for DRM words, but also promoted item-specific encoding. For the condition that promoted item-specific encoding, false memories were reduced for positive and neutral mood conditions to a rate similar to that of the negative mood condition. These experiments demonstrated that negative affective cues promote item-specific processing reducing false memories. People in positive and negative moods encode events differently creating different memories for the same event.
True detection limits in an experimental linearly heteroscedastic system. Part 1
NASA Astrophysics Data System (ADS)
Voigtman, Edward; Abraham, Kevin T.
2011-11-01
Using a lab-constructed laser-excited filter fluorimeter deliberately designed to exhibit linearly heteroscedastic, additive Gaussian noise, it has been shown that accurate estimates may be made of the true theoretical Currie decision levels ( YC and XC) and true Currie detection limits ( YD and XD) for the detection of rhodamine 6 G tetrafluoroborate in ethanol. The obtained experimental values, for 5% probability of false positives and 5% probability of false negatives, were YC = 56.1 mV, YD = 125. mV, XC = 0.132 μg /mL and XD = 0.294 μg /mL. For 5% probability of false positives and 1% probability of false negatives, the obtained detection limits were YD = 158. mV and XD = 0.372 μg /mL. These decision levels and corresponding detection limits were shown to pass the ultimate test: they resulted in observed probabilities of false positives and false negatives that were statistically equivalent to the a priori specified values.
Izumida, Toshihide; Sakata, Hidenao; Nakamura, Masahiko; Hayashibara, Yumiko; Inasaki, Noriko; Inahata, Ryo; Hasegawa, Sumiyo; Takizawa, Takenori; Kaya, Hiroyasu
2016-01-01
An outbreak of dengue fever occurred in Japan in August 2014. We herein report the case of a 63-year-old man who presented with a persistent fever in September 2014. Acute parvovirus B19 infection led to a false positive finding of dengue fever on a rapid diagnostic test (Panbio Dengue Duo Cassette(TM)). To the best of our knowledge, there are no previous reports of a false positive result for dengue IgM with the dengue rapid diagnostic test. We believe that epidemiological information on the prevalence of parvovirus B19 is useful for guiding the interpretation of a positive result with the dengue rapid diagnostic test.
Are Hemorrhoids Associated with False-Positive Fecal Immunochemical Test Results?
Kim, Nam Hee; Park, Jung Ho; Park, Dong Il; Sohn, Chong Il; Choi, Kyuyong
2017-01-01
Purpose False-positive (FP) results of fecal immunochemical tests (FITs) conducted in colorectal cancer (CRC) screening could lead to performing unnecessary colonoscopies. Hemorrhoids are a possible cause of FP FIT results; however, studies on this topic are extremely rare. We investigated whether hemorrhoids are associated with FP FIT results. Materials and Methods A retrospective study was conducted at a university hospital in Korea from June 2013 to May 2015. Of the 34547 individuals who underwent FITs, 3946 aged ≥50 years who underwent colonoscopies were analyzed. Logistic regression analysis was performed to determine factors associated with FP FIT results. Results Among 3946 participants, 704 (17.8%) showed positive FIT results and 1303 (33.0%) had hemorrhoids. Of the 704 participants with positive FIT results, 165 had advanced colorectal neoplasia (ACRN) and 539 had no ACRN (FP results). Of the 1303 participants with hemorrhoids, 291 showed FP results, of whom 81 showed FP results because of hemorrhoids only. Participants with hemorrhoids had a higher rate of FP results than those without hemorrhoids (291/1176, 24.7% vs. 248/2361, 10.5%; p<0.001). Additionally, the participants with hemorrhoids as the only abnormality had a higher rate of FP results than those experiencing no such abnormalities (81/531, 15.3% vs. 38/1173, 3.2%; p<0.001). In multivariate analysis, the presence of hemorrhoids was identified as an independent predictor of FP results (adjusted odds ratio, 2.76; 95% confidence interval, 2.24–3.40; p<0.001). Conclusion Hemorrhoids are significantly associated with FP FIT results. Their presence seemed to be a non-negligible contributor of FP results in FIT-based CRC screening programs. PMID:27873508
Bollmann, Reinhard; Bankfalvi, Agnes; Griefingholt, Harald; Trosic, Ante; Speich, Norbert; Schmitt, Christoph; Bollmann, Magdolna
2005-05-01
Our aim was to improve the accuracy of routine cervical screening by a risk-adapted multimodal protocol with special focus on possible reduction and prognostic assessment of false positive results. A cohort of 31031 women from the Bonn-region in West Germany, median age 36 years, were screened by cytology (conventional or liquid-based), followed by PCR-based HVP detection with genotyping and adjuvant DNA image cytometry, if indicated, in a sequential manner. The true prevalence of high-grade cervical intraepithelial neoplasia and carcinoma (>/=CIN2) was 0.32% in the population as projected from cervical biopsies of 123 women (0.4%), of whom 100 showed >/=CIN2. Sensitivity of the cytology screening program at PapIIID/HSIL threshold for detecting histologically confirmed >/=CIN2 cases was 81%, with specificity, positive predictive value (PPV) and negative predictive value (NPV) of 99, 20.9 and 99.9%, respectively. Of 38 women receiving the complete screening protocol, all the 31 >/=CIN2 cases were correctly detected by cytology alone, 30 by positive high-risk HPV genotype and 30 by aneuploid DNA profile. The combination of the three methods resulted in an up to 6.9% increase in PPV for >/=CIN2 at practically unchanged detection rate with the additional benefit of being able to predict the probable outcome of CIN1 lesions detected as false positives with any single test. Multimodal cervical screening might permit identification of those women with low-grade squamous intraepithelial lesions likely to progress at an earlier and curable stage of disease and lengthen the screening interval in those with transient minor lesions caused by productive HPV infection.
Functional impairment matters in the screening and diagnosis of gaming disorder
Billieux, Joël; King, Daniel L.; Higuchi, Susumu; Achab, Sophia; Bowden-Jones, Henrietta; Hao, Wei; Long, Jiang; Lee, Hae Kook; Potenza, Marc N.; Saunders, John B.; Poznyak, Vladimir
2017-01-01
This commentary responds to Aarseth et al.’s (in press) criticisms that the ICD-11 Gaming Disorder proposal would result in “moral panics around the harm of video gaming” and “the treatment of abundant false-positive cases.” The ICD-11 Gaming Disorder avoids potential “overpathologizing” with its explicit reference to functional impairment caused by gaming and therefore improves upon a number of flawed previous approaches to identifying cases with suspected gaming-related harms. We contend that moral panics are more likely to occur and be exacerbated by misinformation and lack of understanding, rather than proceed from having a clear diagnostic system. PMID:28816514
Guidelines for investigating causality of sequence variants in human disease
MacArthur, D. G.; Manolio, T. A.; Dimmock, D. P.; Rehm, H. L.; Shendure, J.; Abecasis, G. R.; Adams, D. R.; Altman, R. B.; Antonarakis, S. E.; Ashley, E. A.; Barrett, J. C.; Biesecker, L. G.; Conrad, D. F.; Cooper, G. M.; Cox, N. J.; Daly, M. J.; Gerstein, M. B.; Goldstein, D. B.; Hirschhorn, J. N.; Leal, S. M.; Pennacchio, L. A.; Stamatoyannopoulos, J. A.; Sunyaev, S. R.; Valle, D.; Voight, B. F.; Winckler, W.; Gunter, C.
2014-01-01
The discovery of rare genetic variants is accelerating, and clear guidelines for distinguishing disease-causing sequence variants from the many potentially functional variants present in any human genome are urgently needed. Without rigorous standards we risk an acceleration of false-positive reports of causality, which would impede the translation of genomic research findings into the clinical diagnostic setting and hinder biological understanding of disease. Here we discuss the key challenges of assessing sequence variants in human disease, integrating both gene-level and variant-level support for causality. We propose guidelines for summarizing confidence in variant pathogenicity and highlight several areas that require further resource development. PMID:24759409
Gaussian-based filters for detecting Martian dust devils
Yang, F.; Mlsna, P.A.; Geissler, P.
2006-01-01
The ability to automatically detect dust devils in the Martian atmosphere from orbital imagery is becoming important both for scientific studies of the planet and for the planning of future robotic and manned missions. This paper describes our approach for the unsupervised detection of dust devils and the preliminary results achieved to date. The algorithm centers upon the use of a filter constructed from Gaussian profiles to match dust devil characteristics over a range of scale and orientation. The classification step is designed to reduce false positive errors caused by static surface features such as craters. A brief discussion of planned future work is included. ?? 2006 IEEE.
Guidelines for investigating causality of sequence variants in human disease.
MacArthur, D G; Manolio, T A; Dimmock, D P; Rehm, H L; Shendure, J; Abecasis, G R; Adams, D R; Altman, R B; Antonarakis, S E; Ashley, E A; Barrett, J C; Biesecker, L G; Conrad, D F; Cooper, G M; Cox, N J; Daly, M J; Gerstein, M B; Goldstein, D B; Hirschhorn, J N; Leal, S M; Pennacchio, L A; Stamatoyannopoulos, J A; Sunyaev, S R; Valle, D; Voight, B F; Winckler, W; Gunter, C
2014-04-24
The discovery of rare genetic variants is accelerating, and clear guidelines for distinguishing disease-causing sequence variants from the many potentially functional variants present in any human genome are urgently needed. Without rigorous standards we risk an acceleration of false-positive reports of causality, which would impede the translation of genomic research findings into the clinical diagnostic setting and hinder biological understanding of disease. Here we discuss the key challenges of assessing sequence variants in human disease, integrating both gene-level and variant-level support for causality. We propose guidelines for summarizing confidence in variant pathogenicity and highlight several areas that require further resource development.
Functional impairment matters in the screening and diagnosis of gaming disorder.
Billieux, Joël; King, Daniel L; Higuchi, Susumu; Achab, Sophia; Bowden-Jones, Henrietta; Hao, Wei; Long, Jiang; Lee, Hae Kook; Potenza, Marc N; Saunders, John B; Poznyak, Vladimir
2017-09-01
This commentary responds to Aarseth et al.'s (in press) criticisms that the ICD-11 Gaming Disorder proposal would result in "moral panics around the harm of video gaming" and "the treatment of abundant false-positive cases." The ICD-11 Gaming Disorder avoids potential "overpathologizing" with its explicit reference to functional impairment caused by gaming and therefore improves upon a number of flawed previous approaches to identifying cases with suspected gaming-related harms. We contend that moral panics are more likely to occur and be exacerbated by misinformation and lack of understanding, rather than proceed from having a clear diagnostic system.
Dougherty, Carrie
2014-05-01
Occipital pain is a common complaint amongst patients with headache, and the differential can include many primary headache disorders such as cervicogenic headache or migraine. Occipital neuralgia is an uncommon cause of occipital pain characterized by paroxysmal lancinating pain in the distribution of the greater, lesser or third occipital nerves. Greater occipital nerve blockade with anesthetics and/or corticosteroids can aid in confirming the diagnosis and providing pain relief. However, nerve blocks are also effective in migraine headache and misdiagnosis can result in a false positive. Physical therapy and preventive medication with antiepileptics and tricyclic antidepressants are often effective treatments for occipital neuralgia. Refractory cases may require intervention with pulsed radiofrequency or occipital nerve stimulation.
Goldenberg, S D; Cliff, P R; Smith, S; Milner, M; French, G L
2010-01-01
Current diagnosis of Clostridium difficile infection (CDI) relies upon detection of toxins A/B in stool by enzyme immunoassay [EIA(A/B)]. This strategy is unsatisfactory because it has a low sensitivity resulting in significant false negatives. We investigated the performance of a two-step algorithm for diagnosis of CDI using detection of glutamate dehydrogenase (GDH). GDH-positive samples were tested for C. difficile toxin B gene (tcdB) by polymerase chain reaction (PCR). The performance of the two-step protocol was compared with toxin detection by the Meridian Premier EIA kit in 500 consecutive stool samples from patients with suspected CDI. The reference standard among samples that were positive by either EIA(A/B) or GDH testing was culture cytotoxin neutralisation (culture/CTN). Thirty-six (7%) of 500 samples were identified as true positives by culture/CTN. EIA(A/B) identified 14 of the positive specimens with 22 false negatives and two false positives. The two-step protocol identified 34 of the positive samples with two false positives and two false negatives. EIA(A/B) had a sensitivity of 39%, specificity of 99%, positive predictive value of 88% and negative predictive value of 95%. The two-step algorithm performed better, with corresponding values of 94%, 99%, 94% and 99% respectively. Screening for GDH before confirmation of positives by PCR is cheaper than screening all specimens by PCR and is an effective method for routine use. Current EIA(A/B) tests for CDI are of inadequate sensitivity and should be replaced; however, this may result in apparent changes in CDI rates that would need to be explained in national surveillance statistics. Copyright 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
Wavelet method for CT colonography computer-aided polyp detection.
Li, Jiang; Van Uitert, Robert; Yao, Jianhua; Petrick, Nicholas; Franaszek, Marek; Huang, Adam; Summers, Ronald M
2008-08-01
Computed tomographic colonography (CTC) computer aided detection (CAD) is a new method to detect colon polyps. Colonic polyps are abnormal growths that may become cancerous. Detection and removal of colonic polyps, particularly larger ones, has been shown to reduce the incidence of colorectal cancer. While high sensitivities and low false positive rates are consistently achieved for the detection of polyps sized 1 cm or larger, lower sensitivities and higher false positive rates occur when the goal of CAD is to identify "medium"-sized polyps, 6-9 mm in diameter. Such medium-sized polyps may be important for clinical patient management. We have developed a wavelet-based postprocessor to reduce false positives for this polyp size range. We applied the wavelet-based postprocessor to CTC CAD findings from 44 patients in whom 45 polyps with sizes of 6-9 mm were found at segmentally unblinded optical colonoscopy and visible on retrospective review of the CT colonography images. Prior to the application of the wavelet-based postprocessor, the CTC CAD system detected 33 of the polyps (sensitivity 73.33%) with 12.4 false positives per patient, a sensitivity comparable to that of expert radiologists. Fourfold cross validation with 5000 bootstraps showed that the wavelet-based postprocessor could reduce the false positives by 56.61% (p <0.001), to 5.38 per patient (95% confidence interval [4.41, 6.34]), without significant sensitivity degradation (32/45, 71.11%, 95% confidence interval [66.39%, 75.74%], p=0.1713). We conclude that this wavelet-based postprocessor can substantially reduce the false positive rate of our CTC CAD for this important polyp size range.
Breast screening: the use of consensus opinion for all recalls.
Matcham, N J; Ridley, N T F; Taylor, S J; Cook, J-L; Scolding, J
2004-06-01
The quality of a breast-screening programme is measured not only by it's cancer detection rates (sensitivity), but also by it's recall rates and positive predictive values (specificity). False positive screens, which lead to assessments with benign outcomes, can cause psychological and physical morbidity in previously well women. In 1999 the Wiltshire breast-screening programme adopted a novel recall strategy whereby all films marked for recall are subject to consensus opinion--even women "recalled" by both original readers may be returned to routine screening. Since 1999 our recall rates have fallen from above to below the national averages (prevalent 7.2% and incident 3.0% in 2001/02). Specificity has increased over the same period such that approximately one in seven women assessed will be diagnosed with cancer. The consensus meetings provide a forum for teaching and are very popular with our film readers, who all report reduced levels of stress. Copyright 2003 Elsevier Ltd.
Kim, Ko Eun; Jeoung, Jin Wook; Park, Ki Ho; Kim, Dong Myung; Kim, Seok Hwan
2015-03-01
To investigate the rate and associated factors of false-positive diagnostic classification of ganglion cell analysis (GCA) and retinal nerve fiber layer (RNFL) maps, and characteristic false-positive patterns on optical coherence tomography (OCT) deviation maps. Prospective, cross-sectional study. A total of 104 healthy eyes of 104 normal participants. All participants underwent peripapillary and macular spectral-domain (Cirrus-HD, Carl Zeiss Meditec Inc, Dublin, CA) OCT scans. False-positive diagnostic classification was defined as yellow or red color-coded areas for GCA and RNFL maps. Univariate and multivariate logistic regression analyses were used to determine associated factors. Eyes with abnormal OCT deviation maps were categorized on the basis of the shape and location of abnormal color-coded area. Differences in clinical characteristics among the subgroups were compared. (1) The rate and associated factors of false-positive OCT maps; (2) patterns of false-positive, color-coded areas on the GCA deviation map and associated clinical characteristics. Of the 104 healthy eyes, 42 (40.4%) and 32 (30.8%) showed abnormal diagnostic classifications on any of the GCA and RNFL maps, respectively. Multivariate analysis revealed that false-positive GCA diagnostic classification was associated with longer axial length and larger fovea-disc angle, whereas longer axial length and smaller disc area were associated with abnormal RNFL maps. Eyes with abnormal GCA deviation map were categorized as group A (donut-shaped round area around the inner annulus), group B (island-like isolated area), and group C (diffuse, circular area with an irregular inner margin in either). The axial length showed a significant increasing trend from group A to C (P=0.001), and likewise, the refractive error was more myopic in group C than in groups A (P=0.015) and B (P=0.014). Group C had thinner average ganglion cell-inner plexiform layer thickness compared with other groups (group A=B>C, P=0.004). Abnormal OCT diagnostic classification should be interpreted with caution, especially in eyes with long axial lengths, large fovea-disc angles, and small optic discs. Our findings suggest that the characteristic patterns of OCT deviation map can provide useful clues to distinguish glaucomatous changes from false-positive findings. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Mobile chemical detector (AP2C+SP4E) as an aid for medical decision making in the battlefield.
Eisenkraft, Arik; Markel, Gal; Simovich, Shirley; Layish, Ido; Hoffman, Azik; Finkelstein, Arseny; Rotman, Eran; Dushnitsky, Tsvika; Krivoy, Amir
2007-09-01
The combination of the AP2C unit with the SP4E kit composes a lightweight mobile detector of chemical warfare agents (CWA), such as nerve and mustard agents, with both vapor- and liquid-sampling capabilities. This apparatus was recently introduced into our military medical units as an aid for detection of CWA on casualties. Importantly, critical information regarding the applicability in the battlefield was absent. In view of the serious consequences that might follow a proclamation of CWA recognition in battlefield, a high false-positive rate positions the utilization of this apparatus as a medical decision tool in question. We have therefore conducted a field experiment to test the false-positive rate as well as analyze possible factors leading to false-positive readings with this device. The experiment was carried out before and after a 4-day army field exercise, using a standard AP2C device, a SP4E surface sampling kit, and a specially designed medical sampling kit for casualties, intended for medical teams. Soldiers were examined at rest, after mild exercise, and after 4 days in the field. The readings with AP2C alone were compared to the combination of AP2C and SP4E and to the medical sampling kit. Various body fluids served as negative controls. Remarkably, we found a false-positive rate of 57% at rest and after mild exercise, and an even higher rate of 64% after the 4-day field exercise with the AP2C detector alone, as compared to almost no false-positive readings with the combination of AP2C and SP4E. Strikingly, the medical sampling kit has yielded numerous false-positive readings, even in normal body fluids such as blood, urine, and saliva. We therefore see no place for using the medical sampling kit due to an unaccepted high rate of false-positive readings. Finally, we have designed an algorithm that uses the entire apparatus of AP2C and SP4E as a reliable validation tool for medical triage in the setting of exposure to nerve agents in the battlefield.
Santiago, Gilberto A.; Vergne, Edgardo; Quiles, Yashira; Cosme, Joan; Vazquez, Jesus; Medina, Juan F.; Medina, Freddy; Colón, Candimar; Margolis, Harold; Muñoz-Jordán, Jorge L.
2013-01-01
Dengue is an acute illness caused by the positive-strand RNA dengue virus (DENV). There are four genetically distinct DENVs (DENV-1–4) that cause disease in tropical and subtropical countries. Most patients are viremic when they present with symptoms; therefore, RT-PCR has been increasingly used in dengue diagnosis. The CDC DENV-1–4 RT-PCR Assay has been developed as an in-vitro diagnostic platform and was recently approved by the US Food and Drug Administration (FDA) for detection of dengue in patients with signs or symptoms of mild or severe dengue. The primers and probes of this test have been designed to detect currently circulating strains of DENV-1–4 from around the world at comparable sensitivity. In a retrospective study with 102 dengue cases confirmed by IgM anti-DENV seroconversion in the convalescent sample, the RT-PCR Assay detected DENV RNA in 98.04% of the paired acute samples. Using sequencing as a positive indicator, the RT-PCR Assay had a 97.92% positive agreement in 86 suspected dengue patients with a single acute serum sample. After extensive validations, the RT-PCR Assay performance was highly reproducible when evaluated across three independent testing sites, did not produce false positive results for etiologic agents of other febrile illnesses, and was not affected by pathological levels of potentially interfering biomolecules. These results indicate that the CDC DENV-1–4 RT-PCR Assay provides a reliable diagnostic platform capable for confirming dengue in suspected cases. PMID:23875046
False Positive and False Negative Effects on Network Attacks
NASA Astrophysics Data System (ADS)
Shang, Yilun
2018-01-01
Robustness against attacks serves as evidence for complex network structures and failure mechanisms that lie behind them. Most often, due to detection capability limitation or good disguises, attacks on networks are subject to false positives and false negatives, meaning that functional nodes may be falsely regarded as compromised by the attacker and vice versa. In this work, we initiate a study of false positive/negative effects on network robustness against three fundamental types of attack strategies, namely, random attacks (RA), localized attacks (LA), and targeted attack (TA). By developing a general mathematical framework based upon the percolation model, we investigate analytically and by numerical simulations of attack robustness with false positive/negative rate (FPR/FNR) on three benchmark models including Erdős-Rényi (ER) networks, random regular (RR) networks, and scale-free (SF) networks. We show that ER networks are equivalently robust against RA and LA only when FPR equals zero or the initial network is intact. We find several interesting crossovers in RR and SF networks when FPR is taken into consideration. By defining the cost of attack, we observe diminishing marginal attack efficiency for RA, LA, and TA. Our finding highlights the potential risk of underestimating or ignoring FPR in understanding attack robustness. The results may provide insights into ways of enhancing robustness of network architecture and improve the level of protection of critical infrastructures.
A Scalable Approach for Protein False Discovery Rate Estimation in Large Proteomic Data Sets.
Savitski, Mikhail M; Wilhelm, Mathias; Hahne, Hannes; Kuster, Bernhard; Bantscheff, Marcus
2015-09-01
Calculating the number of confidently identified proteins and estimating false discovery rate (FDR) is a challenge when analyzing very large proteomic data sets such as entire human proteomes. Biological and technical heterogeneity in proteomic experiments further add to the challenge and there are strong differences in opinion regarding the conceptual validity of a protein FDR and no consensus regarding the methodology for protein FDR determination. There are also limitations inherent to the widely used classic target-decoy strategy that particularly show when analyzing very large data sets and that lead to a strong over-representation of decoy identifications. In this study, we investigated the merits of the classic, as well as a novel target-decoy-based protein FDR estimation approach, taking advantage of a heterogeneous data collection comprised of ∼19,000 LC-MS/MS runs deposited in ProteomicsDB (https://www.proteomicsdb.org). The "picked" protein FDR approach treats target and decoy sequences of the same protein as a pair rather than as individual entities and chooses either the target or the decoy sequence depending on which receives the highest score. We investigated the performance of this approach in combination with q-value based peptide scoring to normalize sample-, instrument-, and search engine-specific differences. The "picked" target-decoy strategy performed best when protein scoring was based on the best peptide q-value for each protein yielding a stable number of true positive protein identifications over a wide range of q-value thresholds. We show that this simple and unbiased strategy eliminates a conceptual issue in the commonly used "classic" protein FDR approach that causes overprediction of false-positive protein identification in large data sets. The approach scales from small to very large data sets without losing performance, consistently increases the number of true-positive protein identifications and is readily implemented in proteomics analysis software. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.
Clemens, Daniel J; Lentino, Anne R; Kapplinger, Jamie D; Ye, Dan; Zhou, Wei; Tester, David J; Ackerman, Michael J
2018-04-01
Mutations in the KCNQ1-encoded Kv7.1 potassium channel cause long QT syndrome (LQTS) type 1 (LQT1). It has been suggested that ∼10%-20% of rare LQTS case-derived variants in the literature may have been published erroneously as LQT1-causative mutations and may be "false positives." The purpose of this study was to determine which previously published KCNQ1 case variants are likely false positives. A list of all published, case-derived KCNQ1 missense variants (MVs) was compiled. The occurrence of each MV within the Genome Aggregation Database (gnomAD) was assessed. Eight in silico tools were used to predict each variant's pathogenicity. Case-derived variants that were either (1) too frequently found in gnomAD or (2) absent in gnomAD but predicted to be pathogenic by ≤2 tools were considered potential false positives. Three of these variants were characterized functionally using whole-cell patch clamp technique. Overall, there were 244 KCNQ1 case-derived MVs. Of these, 29 (12%) were seen in ≥10 individuals in gnomAD and are demotable. However, 157 of 244 MVs (64%) were absent in gnomAD. Of these, 7 (4%) were predicted to be pathogenic by ≤2 tools, 3 of which we characterized functionally. There was no significant difference in current density between heterozygous KCNQ1-F127L, -P477L, or -L619M variant-containing channels compared to KCNQ1-WT. This study offers preliminary evidence for the demotion of 32 (13%) previously published LQT1 MVs. Of these, 29 were demoted because of their frequent sighting in gnomAD. Additionally, in silico analysis and in vitro functional studies have facilitated the demotion of 3 ultra-rare MVs (F127L, P477L, L619M). Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
A Scalable Approach for Protein False Discovery Rate Estimation in Large Proteomic Data Sets
Savitski, Mikhail M.; Wilhelm, Mathias; Hahne, Hannes; Kuster, Bernhard; Bantscheff, Marcus
2015-01-01
Calculating the number of confidently identified proteins and estimating false discovery rate (FDR) is a challenge when analyzing very large proteomic data sets such as entire human proteomes. Biological and technical heterogeneity in proteomic experiments further add to the challenge and there are strong differences in opinion regarding the conceptual validity of a protein FDR and no consensus regarding the methodology for protein FDR determination. There are also limitations inherent to the widely used classic target–decoy strategy that particularly show when analyzing very large data sets and that lead to a strong over-representation of decoy identifications. In this study, we investigated the merits of the classic, as well as a novel target–decoy-based protein FDR estimation approach, taking advantage of a heterogeneous data collection comprised of ∼19,000 LC-MS/MS runs deposited in ProteomicsDB (https://www.proteomicsdb.org). The “picked” protein FDR approach treats target and decoy sequences of the same protein as a pair rather than as individual entities and chooses either the target or the decoy sequence depending on which receives the highest score. We investigated the performance of this approach in combination with q-value based peptide scoring to normalize sample-, instrument-, and search engine-specific differences. The “picked” target–decoy strategy performed best when protein scoring was based on the best peptide q-value for each protein yielding a stable number of true positive protein identifications over a wide range of q-value thresholds. We show that this simple and unbiased strategy eliminates a conceptual issue in the commonly used “classic” protein FDR approach that causes overprediction of false-positive protein identification in large data sets. The approach scales from small to very large data sets without losing performance, consistently increases the number of true-positive protein identifications and is readily implemented in proteomics analysis software. PMID:25987413
Mandelblatt, Jeanne S.; Stout, Natasha K.; Schechter, Clyde B.; van den Broek, Jeroen J.; Miglioretti, Diana; Krapcho, Martin; Trentham-Dietz, Amy; Munoz, Diego; Lee, Sandra J.; Berry, Donald A.; van Ravesteyn, Nicolien T.; Alagoz, Oguzhan; Kerlikowske, Karla; Tosteson, Anna N.A.; Near, Aimee M.; Hoeffken, Amanda; Chang, Yaojen; Heijnsdijk, Eveline A.; Chisholm, Gary; Huang, Xuelin; Huang, Hui; Ergun, Mehmet Ali; Gangnon, Ronald; Sprague, Brian L.; Plevritis, Sylvia; Feuer, Eric; de Koning, Harry J.; Cronin, Kathleen A.
2016-01-01
Background Controversy persists about optimal mammography screening strategies. Objective To evaluate mammography strategies considering screening and treatment advances. Design Collaboration of six simulation models. Data Sources National data on incidence, risk, breast density, digital mammography performance, treatment effects, and other-cause mortality. Target Population An average-risk cohort. Time Horizon Lifetime. Perspective Societal. Interventions Mammograms from age 40, 45 or 50 to 74 at annual or biennial intervals, or annually from 40 or 45 to 49 then biennially to 74, assuming 100% screening and treatment adherence. Outcome Measures Screening benefits (vs. no screening) include percent breast cancer mortality reduction, deaths averted, and life-years gained. Harms include number of mammograms, false-positives, benign biopsies, and overdiagnosis. Results for Average-Risk Women Biennial strategies maintain 79.8%-81.3% (range across strategies and models: 68.3–98.9%) of annual screening benefits with almost half the false-positives and fewer overdiagnoses. Screening biennially from ages 50–74 achieves a median 25.8% (range: 24.1%-31.8%) breast cancer mortality reduction; annual screening from ages 40–74 years reduces mortality an additional 12.0% (range: 5.7%-17.2%) vs. no screening, but yields 1988 more false-positives and 7 more overdiagnoses per 1000 women screened. Annual screening from ages 50–74 had similar benefits as other strategies but more harms, so would not be recommended. Sub-population Results Annual screening starting at age 40 for women who have a two- to four-fold increase in risk has a similar balance of harms and benefits as biennial screening of average-risk women from 50–74. Limitations We do not consider other imaging technologies, polygenic risk, or non-adherence. Conclusion These results suggest that biennial screening is efficient for average-risk groups, but decisions on strategies depend on the weight given to the balance of harms and benefits. Primary Funding Source National Institutes of Health PMID:26756606
Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun
2018-06-01
Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P < .05). The diagnostic accuracy was best in nodules of 5 to 10 mm in diameter. The sensitivity, accuracy, PPV, and LR for negative US-guided FNA results were better in nodules with a size range of 5 to 15 mm. The specificity, negative predictive value (NPV), and LR for positive results and the Youden index rose with increasing nodule size. Seventeen false-positive and 60 false-negative results were found in this study. The false-negative rate rose with increasing nodule size. However, the false-positive rate was highest in the group containing the smallest nodules. Nodules with circumscribed margins and those that were nonsolid and nonhypoechoic and had no microcalcifications correlated with Bethesda I FNA results. Nodules with circumscribed margins and those that were nonsolid, heterogeneous, and nonhypoechoic and had increased vascularity correlated with false-negative FNA results. Borders correlated with Bethesda I false-negative and false-positive FNA results. Tiny nodules (≤5 mm) with obscure borders tended to yield false-positive FNA results. Large nodules (>20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.
Neural events that underlie remembering something that never happened.
Gonsalves, B; Paller, K A
2000-12-01
We induced people to experience a false-memory illusion by first asking them to visualize common objects when cued with the corresponding word; on some trials, a photograph of the object was presented 1800 ms after the cue word. We then tested their memory for the photographs. Posterior brain potentials in response to words at encoding were more positive if the corresponding object was later falsely remembered as a photograph. Similar brain potentials during the memory test were more positive for true than for false memories. These results implicate visual imagery in the generation of false memories and provide neural correlates of processing differences between true and false memories.
Otten, J D M; Fracheboud, J; den Heeten, G J; Otto, S J; Holland, R; de Koning, H J; Broeders, M J M; Verbeek, A L M
2013-10-01
Women require balanced, high-quality information when making an informed decision on screening benefits and harms before attending biennial mammographic screening. The cumulative risk of a false-positive recall and/or (small) screen-detected or interval cancer over 13 consecutive screening examinations for women aged 50 from the start of screening were estimated using data from the Nijmegen programme, the Netherlands. Women who underwent 13 successive screens in the period 1975-1976 had a 5.3% cumulative chance of a screen-detected cancer, with a 4.2% risk of at least one false-positive recall. The risk of being diagnosed with interval cancer was 3.7%. Two decades later, these estimates were 6.9%, 7.3% and 2.9%, respectively. The chance of detection of a small, favourable invasive breast cancer, anticipating a normal life-expectancy, rose from 2.3% to 3.7%. Extrapolation to digital screening mammography indicates that the proportion of false-positive results will rise to 16%. Dutch women about to participate in the screening programme can be reassured that the chance of false-positive recall in the Netherlands is relatively low. A new screening policy and improved mammography have increased the detection of an early screening carcinoma and lowering the risk of interval carcinoma.
False-positive results in pharmacoepidemiology and pharmacovigilance.
Bezin, Julien; Bosco-Levy, Pauline; Pariente, Antoine
2017-09-01
False-positive constitute an important issue in scientific research. In the domain of drug evaluation, it affects all phases of drug development and assessment, from the very early preclinical studies to the late post-marketing evaluations. The core concern associated with this false-positive is the lack of replicability of the results. Aside from fraud or misconducts, false-positive is often envisioned from the statistical angle, which considers them as a price to pay for type I error in statistical testing, and its inflation in the context of multiple testing. If envisioning this problematic in the context of pharmacoepidemiology and pharmacovigilance however, that both evaluate drugs in an observational settings, information brought by statistical testing and the significance of such should only be considered as additional to the estimates provided and their confidence interval, in a context where differences have to be a clinically meaningful upon everything, and the results appear robust to the biases likely to have affected the studies. In the following article, we consequently illustrate these biases and their consequences in generating false-positive results, through studies and associations between drug use and health outcomes that have been widely disputed. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.
Gagliardi, L; Chapman, I M; O'Loughlin, P; Torpy, D J
2010-04-01
The diagnosis of subclinical Cushing's syndrome (SCS) is important, but its relative rarity amongst patients with common metabolic disorders requires a simple test with a low false-positive rate. Using nocturnal salivary cortisol (NSC), which we first validated in patients with suspected and proven Cushing's syndrome, we screened 106 overweight patients with type 2 diabetes mellitus, a group at high risk of SCS and nontumoral hypothalamic-pituitary-adrenal axis perturbations. Our hypothesis was that a lower false-positive rate with NSC was likely, compared with that reported with the dexamethasone suppression test (DST) (10-20%), currently the foundation of diagnosis of SCS. No participant had clinically apparent Cushing's syndrome. Three participants had an elevated NSC but further testing excluded SCS. In this study, NSC had a lower false-positive rate (3%) than previously reported for the DST. Given the reported excellent performance of NSC in detection of hypercortisolism, the low false-positive rate in SCS suggests NSC may be superior to the DST for SCS screening. The NSC and DST should be compared directly in metabolic disorder patients; although our data suggest the patient group will need to be substantially larger to definitively determine the optimal screening test. Georg Thieme Verlag KG Stuttgart New York.
Tetteh, Ato Kwamena; Agyarko, Edward
2017-01-01
Screening results of 488 pregnant women aged 15-44 years whose blood samples had been tested on-site, using First Response® HIV 1/2, and confirmed with INNO-LIA™ HIV I/II Score were used. Of this total, 178 were reactive (HIV I, 154; HIV II, 2; and HIV I and HIV II, 22). Of the 154 HIV I-reactive samples, 104 were confirmed to be HIV I-positive and 2 were confirmed to be HIV II-positive, while 48 were confirmed to be negative [false positive rate = 17.44% (13.56-21.32)]. The two HIV II samples submitted were confirmed to be negative with the confirmatory test. For the 22 HIV I and HIV II samples, 7 were confirmed to be HIV I-positive and 1 was confirmed to be HIV I- and HIV II-positive, while 14 were confirmed to be negative. Of the 310 nonreactive samples, 6 were confirmed to be HIV I-positive and 1 was confirmed to be HIV II-positive [false negative rate = 5.79% (1.63-8.38)], while 303 were negative. False negative outcomes will remain unconfirmed, with no management options for the client. False negative rate of 5.79% requires attention, as its resultant implications on control of HIV/AIDS could be dire.
Guan, Zhonghui; Baker, Keith; Sandberg, Warren S
2009-11-01
We report a small case series in which misaligned disposable pulse oximeter sensors gave falsely low saturation readings. In each instance, the sensor performed well during preinduction oxygen administration and the early part of the case, most notably by producing a plethysmographic trace rated as high quality by the oximeter software. The reported pulse oximeter oxygen saturation eventually decreased to concerning levels in each instance, but the anesthesiologists, relying on the reported high-quality signal, initially sought other causes for apparent hypoxia. They undertook maneuvers and diagnostic procedures later deemed unnecessary. When the malpositioned sensors were discovered and repositioned, the apparent hypoxia was quickly relieved in each case. We then undertook a survey of disposable oximeter sensors as patients entered the recovery room, and discovered malposition of more than 1 cm in approximately 20% of all sensors, without apparent consequence. We conclude that the technology is quite robust, but that the diagnosis of apparent hypoxia should include a quick check of oximeter position early on.
NASA Astrophysics Data System (ADS)
Ozsahin, I.; Unlu, M. Z.
2014-03-01
Breast cancer is the most common leading cause of cancer death among women. Positron Emission Tomography (PET) Mammography, also known as Positron Emission Mammography (PEM), is a method for imaging primary breast cancer. Over the past few years, PEMs based on scintillation crystals dramatically increased their importance in diagnosis and treatment of early stage breast cancer. However, these detectors have significant limitations like poor energy resolution resulting with false-negative result (missed cancer), and false-positive result which leads to suspecting cancer and suggests an unnecessary biopsy. In this work, a PEM scanner based on CdTe strip detectors is simulated via the Monte Carlo method and evaluated in terms of its spatial resolution, sensitivity, and image quality. The spatial resolution is found to be ~ 1 mm in all three directions. The results also show that CdTe strip detectors based PEM scanner can produce high resolution images for early diagnosis of breast cancer.
Schouten, M C M; Karst, W A; van der Stel, H F; Teeuw, A H; van de Putte, E M
2016-01-01
A false accusation of child abuse has a major impact on child and family. Conversely, a missed diagnosis of child abuse may have significant and lifelong consequences for the child. For health professionals the assessment of the nature of the injury and differentiating between accidental and inflicted injury, disease manifestation or a physiological phenomenon can be challenging. For adequate determination of the cause of injury, an integrated approach including paediatric knowledge and forensic medical expertise is essential. Therefore, a national expertise centre for child abuse (LECK) was established in the Netherlands in 2014. The first results of this integrated approach are described and illustrated with three case reports. Case A, a 7-month-old boy with an accidental humerus fracture. Case B, an 8-year-old boy with a false positive suspicion of child abuse who was eventually diagnosed with Henoch-Schönlein syndrome. Case C, boy of 3 months with bruises and a metaphyseal fracture of the femur, both highly suspected of being inflicted injury.
Human antibodies to bovine alpha-globulin.
Foucard, T; Bennich, H; Johansson, S G; Lundkvist, U
1975-01-01
Antibodies to bovine gamma-globulin (anti-BGG antibodies) were detectable by a radio-immunoassay in 70% of healthy blood donors but, generally, the titres were low. Significantly increased concentrations of anti-BGG antibodies were found in patients lacking IgA but not in patients with allergic disorders. The anti-BGG antibodies were shown to give rise to falsely high IgE values in the radio-immunosorbent test for IgE determination (RIST) when a sheep anti-IgE antiserum was used. Furthermore, falsely positive results can sometimes be caused by such antibodies in the determination of cow-dander- or cow's-milk-specific IgE by the radio-allergosorbent test (RAST). When a rabbit anti-IgE antiserum was used instead of the sheep anti-IgE, normal IgE levels and negative RAST results were obtained. The difference is explained by the higher degree of cross-reactivity between the anti-BGG antibodies and sheep alpha-globulin than between anti-BGG antibodies and rabbit alpha-globulin.
Chen, Qianting; Dai, Congling; Zhang, Qianjun; Du, Juan; Li, Wen
2016-10-01
To study the prediction performance evaluation with five kinds of bioinformatics software (SIFT, PolyPhen2, MutationTaster, Provean, MutationAssessor). From own database for genetic mutations collected over the past five years, Chinese literature database, Human Gene Mutation Database, and dbSNP, 121 missense mutations confirmed by functional studies, and 121 missense mutations suspected to be pathogenic by pedigree analysis were used as positive gold standard, while 242 missense mutations with minor allele frequency (MAF)>5% in dominant hereditary diseases were used as negative gold standard. The selected mutations were predicted with the five software. Based on the results, the performance of the five software was evaluated for their sensitivity, specificity, positive predict value, false positive rate, negative predict value, false negative rate, false discovery rate, accuracy, and receiver operating characteristic curve (ROC). In terms of sensitivity, negative predictive value and false negative rate, the rank was MutationTaster, PolyPhen2, Provean, SIFT, and MutationAssessor. For specificity and false positive rate, the rank was MutationTaster, Provean, MutationAssessor, SIFT, and PolyPhen2. For positive predict value and false discovery rate, the rank was MutationTaster, Provean, MutationAssessor, PolyPhen2, and SIFT. For area under the ROC curve (AUC) and accuracy, the rank was MutationTaster, Provean, PolyPhen2, MutationAssessor, and SIFT. The prediction performance of software may be different when using different parameters. Among the five software, MutationTaster has the best prediction performance.
Solution to the SLAM problem in low dynamic environments using a pose graph and an RGB-D sensor.
Lee, Donghwa; Myung, Hyun
2014-07-11
In this study, we propose a solution to the simultaneous localization and mapping (SLAM) problem in low dynamic environments by using a pose graph and an RGB-D (red-green-blue depth) sensor. The low dynamic environments refer to situations in which the positions of objects change over long intervals. Therefore, in the low dynamic environments, robots have difficulty recognizing the repositioning of objects unlike in highly dynamic environments in which relatively fast-moving objects can be detected using a variety of moving object detection algorithms. The changes in the environments then cause groups of false loop closing when the same moved objects are observed for a while, which means that conventional SLAM algorithms produce incorrect results. To address this problem, we propose a novel SLAM method that handles low dynamic environments. The proposed method uses a pose graph structure and an RGB-D sensor. First, to prune the falsely grouped constraints efficiently, nodes of the graph, that represent robot poses, are grouped according to the grouping rules with noise covariances. Next, false constraints of the pose graph are pruned according to an error metric based on the grouped nodes. The pose graph structure is reoptimized after eliminating the false information, and the corrected localization and mapping results are obtained. The performance of the method was validated in real experiments using a mobile robot system.
Sakurai, Fuminori; Narii, Nobuhiro; Tomita, Kyoko; Togo, Shinsaku; Takahashi, Kazuhisa; Machitani, Mitsuhiro; Tachibana, Masashi; Ouchi, Masaaki; Katagiri, Nobuyoshi; Urata, Yasuo; Fujiwara, Toshiyoshi; Mizuguchi, Hiroyuki
2016-01-01
Circulating tumor cells (CTCs) are promising biomarkers in several cancers, and thus methods and apparatuses for their detection and quantification in the blood have been actively pursued. A novel CTC detection system using a green fluorescence protein (GFP)–expressing conditionally replicating adenovirus (Ad) (rAd-GFP) was recently developed; however, there is concern about the production of false-positive cells (GFP-positive normal blood cells) when using rAd-GFP, particularly at high titers. In addition, CTCs lacking or expressing low levels of coxsackievirus–adenovirus receptor (CAR) cannot be detected by rAd-GFP, because rAd-GFP is constructed based on Ad serotype 5, which recognizes CAR. In order to suppress the production of false-positive cells, sequences perfectly complementary to blood cell–specific microRNA, miR-142-3p, were incorporated into the 3′-untranslated region of the E1B and GFP genes. In addition, the fiber protein was replaced with that of Ad serotype 35, which recognizes human CD46, creating rAdF35-142T-GFP. rAdF35-142T-GFP efficiently labeled not only CAR-positive tumor cells but also CAR-negative tumor cells with GFP. The numbers of false-positive cells were dramatically lower for rAdF35-142T-GFP than for rAd-GFP. CTCs in the blood of cancer patients were detected by rAdF35-142T-GFP with a large reduction in false-positive cells. PMID:26966699
2015-01-01
Molecular docking is a powerful tool used in drug discovery and structural biology for predicting the structures of ligand–receptor complexes. However, the accuracy of docking calculations can be limited by factors such as the neglect of protein reorganization in the scoring function; as a result, ligand screening can produce a high rate of false positive hits. Although absolute binding free energy methods still have difficulty in accurately rank-ordering binders, we believe that they can be fruitfully employed to distinguish binders from nonbinders and reduce the false positive rate. Here we study a set of ligands that dock favorably to a newly discovered, potentially allosteric site on the flap of HIV-1 protease. Fragment binding to this site stabilizes a closed form of protease, which could be exploited for the design of allosteric inhibitors. Twenty-three top-ranked protein–ligand complexes from AutoDock were subject to the free energy screening using two methods, the recently developed binding energy analysis method (BEDAM) and the standard double decoupling method (DDM). Free energy calculations correctly identified most of the false positives (≥83%) and recovered all the confirmed binders. The results show a gap averaging ≥3.7 kcal/mol, separating the binders and the false positives. We present a formula that decomposes the binding free energy into contributions from the receptor conformational macrostates, which provides insights into the roles of different binding modes. Our binding free energy component analysis further suggests that improving the treatment for the desolvation penalty associated with the unfulfilled polar groups could reduce the rate of false positive hits in docking. The current study demonstrates that the combination of docking with free energy methods can be very useful for more accurate ligand screening against valuable drug targets. PMID:25189630
Cumulative Incidence of False-Positive Results in Repeated, Multimodal Cancer Screening
Croswell, Jennifer Miller; Kramer, Barnett S.; Kreimer, Aimee R.; Prorok, Phil C.; Xu, Jian-Lun; Baker, Stuart G.; Fagerstrom, Richard; Riley, Thomas L.; Clapp, Jonathan D.; Berg, Christine D.; Gohagan, John K.; Andriole, Gerald L.; Chia, David; Church, Timothy R.; Crawford, E. David; Fouad, Mona N.; Gelmann, Edward P.; Lamerato, Lois; Reding, Douglas J.; Schoen, Robert E.
2009-01-01
PURPOSE Multiple cancer screening tests have been advocated for the general population; however, clinicians and patients are not always well-informed of screening burdens. We sought to determine the cumulative risk of a false-positive screening result and the resulting risk of a diagnostic procedure for an individual participating in a multimodal cancer screening program. METHODS Data were analyzed from the intervention arm of the ongoing Prostate, Lung, Colorectal, and Ovarian (PLCO) Cancer Screening Trial, a randomized controlled trial to determine the effects of prostate, lung, colorectal, and ovarian cancer screening on disease-specific mortality. The 68,436 participants, aged 55 to 74 years, were randomized to screening or usual care. Women received serial serum tests to detect cancer antigen 125 (CA-125), transvaginal sonograms, posteroanterior-view chest radiographs, and flexible sigmoidoscopies. Men received serial chest radiographs, flexible sigmoidoscopies, digital rectal examinations, and serum prostate-specific antigen tests. Fourteen screening examinations for each sex were possible during the 3-year screening period. RESULTS After 14 tests, the cumulative risk of having at least 1 false-positive screening test is 60.4% (95% CI, 59.8%–61.0%) for men, and 48.8% (95% CI, 48.1%–49.4%) for women. The cumulative risk after 14 tests of undergoing an invasive diagnostic procedure prompted by a false-positive test is 28.5% (CI, 27.8%–29.3%) for men and 22.1% (95% CI, 21.4%–22.7%) for women. CONCLUSIONS For an individual in a multimodal cancer screening trial, the risk of a false-positive finding is about 50% or greater by the 14th test. Physicians should educate patients about the likelihood of false positives and resulting diagnostic interventions when counseling about cancer screening. PMID:19433838
Wiwanitkit, Viroj; Udomsantisuk, Nibhond; Boonchalermvichian, Chaiyaporn
2005-06-01
The aim of this study was to evaluate the diagnostic properties of urine Gram stain and urine microscopic examination for screening for urinary tract infection (UTI), and to perform an additional cost utility analysis. This descriptive study was performed on 95 urine samples sent for urine culture to the Department of Microbiology, Faculty of Medicine, Chulalongkorn University. The first part of the study was to determine the diagnostic properties of two screening tests (urine Gram stain and urine microscopic examination). Urine culture was set as the gold standard and the results from both methods were compared to this. The second part of this study was to perform a cost utility analysis. The sensitivity of urine Gram stain was 96.2%, the specificity 93.0%, the positive predictive value 94.3% and the negative predictive value 95.2%. False positives occurred with a frequency of 7.0% and false negatives 3.8%. For the microscopic examination, the sensitivity was 65.4%, specificity 74.4%, positive predictive value 75.6% and negative predictive value 64.0%. False positives occurred with a frequency of 25.6% and false negatives 34.6%. Combining urine Gram stain and urine microscopic examination, the sensitivity was 98.1%, specificity 74.4%, positive predictive value 82.3% and negative predictive value 97.0%. False positives occurred with a frequency of 25.6% and false negatives 1.9%. However, the cost per utility of the combined method was higher than either urine microscopic examination or urine Gram stain alone. Urine Gram stain provided the lowest cost per utility. Economically, urine Gram stain is the proper screening tool for presumptive diagnosis of UTI.
NASA Astrophysics Data System (ADS)
de Oliveira, Helder C. R.; Mencattini, Arianna; Casti, Paola; Martinelli, Eugenio; di Natale, Corrado; Catani, Juliana H.; de Barros, Nestor; Melo, Carlos F. E.; Gonzaga, Adilson; Vieira, Marcelo A. C.
2018-02-01
This paper proposes a method to reduce the number of false-positives (FP) in a computer-aided detection (CAD) scheme for automated detection of architectural distortion (AD) in digital mammography. AD is a subtle contraction of breast parenchyma that may represent an early sign of breast cancer. Due to its subtlety and variability, AD is more difficult to detect compared to microcalcifications and masses, and is commonly found in retrospective evaluations of false-negative mammograms. Several computer-based systems have been proposed for automated detection of AD in breast images. The usual approach is automatically detect possible sites of AD in a mammographic image (segmentation step) and then use a classifier to eliminate the false-positives and identify the suspicious regions (classification step). This paper focus on the optimization of the segmentation step to reduce the number of FPs that is used as input to the classifier. The proposal is to use statistical measurements to score the segmented regions and then apply a threshold to select a small quantity of regions that should be submitted to the classification step, improving the detection performance of a CAD scheme. We evaluated 12 image features to score and select suspicious regions of 74 clinical Full-Field Digital Mammography (FFDM). All images in this dataset contained at least one region with AD previously marked by an expert radiologist. The results showed that the proposed method can reduce the false positives of the segmentation step of the CAD scheme from 43.4 false positives (FP) per image to 34.5 FP per image, without increasing the number of false negatives.
Basketter, David A; Gerberick, G Frank; Kimber, Ian
2007-01-01
The local lymph node assay (LLNA) is being used increasingly in the identification of skin sensitizing chemicals for regulatory purposes. In the context of new chemicals legislation (REACH) in Europe, it is the preferred assay. The rationale for this is that the LLNA quantitative and objective approach to skin sensitization testing allied with the important animal welfare benefits that the method offers. However, as with certain guinea pig sensitization tests before it, this increasing use also brings experience with an increasingly wide range of industrial and other chemicals where the outcome of the assay does not always necessarily meet with the expectations of those conducting it. Sometimes, the result appears to be a false negative, but rather more commonly, the complaint is that the chemical represents a false positive. Against this background we have here reviewed a number of instances where false positive and false negative results have been described and have sought to reconcile science with expectation. Based on these analyses, it is our conclusion that false positives and false negatives do occur in the LLNA, as they do with any other skin sensitization assay (and indeed with all tests used for hazard identification), and that this occurs for a number of reasons. We further conclude, however, that false positive results in the LLNA, as with the guinea pig maximization test, arise most commonly via failure to distinguish what is scientifically correct from that which is unpalatable. The consequences of this confusion are discussed in the article, particularly in relation to the need to integrate both potency measurement and risk assessments into classification and labelling schemes that aim to manage potential risks to human health.
Miller, David A W; Nichols, James D; Gude, Justin A; Rich, Lindsey N; Podruzny, Kevin M; Hines, James E; Mitchell, Michael S
2013-01-01
Large-scale presence-absence monitoring programs have great promise for many conservation applications. Their value can be limited by potential incorrect inferences owing to observational errors, especially when data are collected by the public. To combat this, previous analytical methods have focused on addressing non-detection from public survey data. Misclassification errors have received less attention but are also likely to be a common component of public surveys, as well as many other data types. We derive estimators for dynamic occupancy parameters (extinction and colonization), focusing on the case where certainty can be assumed for a subset of detections. We demonstrate how to simultaneously account for non-detection (false negatives) and misclassification (false positives) when estimating occurrence parameters for gray wolves in northern Montana from 2007-2010. Our primary data source for the analysis was observations by deer and elk hunters, reported as part of the state's annual hunter survey. This data was supplemented with data from known locations of radio-collared wolves. We found that occupancy was relatively stable during the years of the study and wolves were largely restricted to the highest quality habitats in the study area. Transitions in the occupancy status of sites were rare, as occupied sites almost always remained occupied and unoccupied sites remained unoccupied. Failing to account for false positives led to over estimation of both the area inhabited by wolves and the frequency of turnover. The ability to properly account for both false negatives and false positives is an important step to improve inferences for conservation from large-scale public surveys. The approach we propose will improve our understanding of the status of wolf populations and is relevant to many other data types where false positives are a component of observations.
Finkel, Eli J; Eastwick, Paul W; Reis, Harry T
2015-02-01
In recent years, a robust movement has emerged within psychology to increase the evidentiary value of our science. This movement, which has analogs throughout the empirical sciences, is broad and diverse, but its primary emphasis has been on the reduction of statistical false positives. The present article addresses epistemological and pragmatic issues that we, as a field, must consider as we seek to maximize the scientific value of this movement. Regarding epistemology, this article contrasts the false-positives-reduction (FPR) approach with an alternative, the error balance (EB) approach, which argues that any serious consideration of optimal scientific practice must contend simultaneously with both false-positive and false-negative errors. Regarding pragmatics, the movement has devoted a great deal of attention to issues that frequently arise in laboratory experiments and one-shot survey studies, but it has devoted less attention to issues that frequently arise in intensive and/or longitudinal studies. We illustrate these epistemological and pragmatic considerations with the case of relationship science, one of the many research domains that frequently employ intensive and/or longitudinal methods. Specifically, we examine 6 research prescriptions that can help to reduce false-positive rates: preregistration, prepublication sharing of materials, postpublication sharing of data, close replication, avoiding piecemeal publication, and increasing sample size. For each, we offer concrete guidance not only regarding how researchers can improve their research practices and balance the risk of false-positive and false-negative errors, but also how the movement can capitalize upon insights from research practices within relationship science to make the movement stronger and more inclusive. PsycINFO Database Record (c) 2015 APA, all rights reserved.
Are the memories of older adults positively biased?
Fernandes, Myra; Ross, Michael; Wiegand, Melanie; Schryer, Emily
2008-06-01
There is disagreement in the literature about whether a "positivity effect" in memory performance exists in older adults. To assess the generalizability of the effect, the authors examined memory for autobiographical, picture, and word information in a group of younger (17-29 years old) and older (60-84 years old) adults. For the autobiographical memory task, the authors asked participants to produce 4 positive, 4 negative, and 4 neutral recent autobiographical memories and to recall these a week later. For the picture and word tasks, participants studied photos or words of different valences (positive, negative, neutral) and later remembered them on a free-recall test. The authors found significant correlations in memory performance, across task material, for recall of both positive and neutral valence autobiographical events, pictures, and words. When the authors examined accurate memories, they failed to find consistent evidence, across the different types of material, of a positivity effect in either age group. However, the false memory findings offer more consistent support for a positivity effect in older adults. During recall of all 3 types of material, older participants recalled more false positive than false negative memories.
Two-species occupancy modeling accounting for species misidentification and nondetection
Chambert, Thierry; Grant, Evan H. Campbell; Miller, David A. W.; Nichols, James; Mulder, Kevin P.; Brand, Adrianne B,
2018-01-01
In occupancy studies, species misidentification can lead to false‐positive detections, which can cause severe estimator biases. Currently, all models that account for false‐positive errors only consider omnibus sources of false detections and are limited to single‐species occupancy.However, false detections for a given species often occur because of the misidentification with another, closely related species. To exploit this explicit source of false‐positive detection error, we develop a two‐species occupancy model that accounts for misidentifications between two species of interest. As with other false‐positive models, identifiability is greatly improved by the availability of unambiguous detections at a subset of site x occasions. Here, we consider the case where some of the field observations can be confirmed using laboratory or other independent identification methods (“confirmatory data”).We performed three simulation studies to (1) assess the model's performance under various realistic scenarios, (2) investigate the influence of the proportion of confirmatory data on estimator accuracy and (3) compare the performance of this two‐species model with that of the single‐species false‐positive model. The model shows good performance under all scenarios, even when only small proportions of detections are confirmed (e.g. 5%). It also clearly outperforms the single‐species model.We illustrate application of this model using a 4‐year dataset on two sympatric species of lungless salamanders: the US federally endangered Shenandoah salamander Plethodon shenandoah, and its presumed competitor, the red‐backed salamander Plethodon cinereus. Occupancy of red‐backed salamanders appeared very stable across the 4 years of study, whereas the Shenandoah salamander displayed substantial turnover in occupancy of forest habitats among years.Given the extent of species misidentification issues in occupancy studies, this modelling approach should help improve the reliability of estimates of species distribution, which is the goal of many studies and monitoring programmes. Further developments, to account for different forms of state uncertainty, can be readily undertaken under our general approach.
Xu, X W; Doi, K; Kobayashi, T; MacMahon, H; Giger, M L
1997-09-01
Lung cancer is the leading cause of cancer deaths in men and women in the United States, with a 5-year survival rate of only about 13%. However, this survival rate can be improved to 47% if the disease is diagnosed and treated at an early stage. In this study, we developed an improved computer-aided diagnosis (CAD) scheme for the automated detection of lung nodules in digital chest images to assist radiologists, who could miss up to 30% of the actually positive cases in their daily practice. Two hundred PA chest radiographs, 100 normals and 100 abnormals, were used as the database for our study. The presence of nodules in the 100 abnormal cases was confirmed by two experienced radiologists on the basis of CT scans or radiographic follow-up. In our CAD scheme, nodule candidates were selected initially by multiple gray-level thresholding of the difference image (which corresponds to the subtraction of a signal-enhanced image and a signal-suppressed image) and then classified into six groups. A large number of false positives were eliminated by adaptive rule-based tests and an artificial neural network (ANN). The CAD scheme achieved, on average, a sensitivity of 70% with 1.7 false positives per chest image, a performance which was substantially better as compared with other studies. The CPU time for the processing of one chest image was about 20 seconds on an IBM RISC/6000 Powerstation 590. We believe that the CAD scheme with the current performance is ready for initial clinical evaluation.
Standoff detection of chemical and biological threats using laser-induced breakdown spectroscopy.
Gottfried, Jennifer L; De Lucia, Frank C; Munson, Chase A; Miziolek, Andrzej W
2008-04-01
Laser-induced breakdown spectroscopy (LIBS) is a promising technique for real-time chemical and biological warfare agent detection in the field. We have demonstrated the detection and discrimination of the biological warfare agent surrogates Bacillus subtilis (BG) (2% false negatives, 0% false positives) and ovalbumin (0% false negatives, 1% false positives) at 20 meters using standoff laser-induced breakdown spectroscopy (ST-LIBS) and linear correlation. Unknown interferent samples (not included in the model), samples on different substrates, and mixtures of BG and Arizona road dust have been classified with reasonable success using partial least squares discriminant analysis (PLS-DA). A few of the samples tested such as the soot (not included in the model) and the 25% BG:75% dust mixture resulted in a significant number of false positives or false negatives, respectively. Our preliminary results indicate that while LIBS is able to discriminate biomaterials with similar elemental compositions at standoff distances based on differences in key intensity ratios, further work is needed to reduce the number of false positives/negatives by refining the PLS-DA model to include a sufficient range of material classes and carefully selecting a detection threshold. In addition, we have demonstrated that LIBS can distinguish five different organophosphate nerve agent simulants at 20 meters, despite their similar stoichiometric formulas. Finally, a combined PLS-DA model for chemical, biological, and explosives detection using a single ST-LIBS sensor has been developed in order to demonstrate the potential of standoff LIBS for universal hazardous materials detection.
Banks, Emily; Reeves, Gillian; Beral, Valerie; Bull, Diana; Crossley, Barbara; Simmonds, Moya; Hilton, Elizabeth; Bailey, Stephen; Barrett, Nigel; Briers, Peter; English, Ruth; Jackson, Alan; Kutt, Elizabeth; Lavelle, Janet; Rockall, Linda; Wallis, Matthew G; Wilson, Mary; Patnick, Julietta
2006-01-01
Introduction Current and recent users of hormone replacement therapy (HRT) have an increased risk of being recalled to assessment at mammography without breast cancer being diagnosed ('false positive recall'), but there is limited information on the effects of different patterns of HRT use on this. The aim of this study is to investigate in detail the relationship between patterns of use of HRT and false positive recall. Methods A total of 87,967 postmenopausal women aged 50 to 64 years attending routine breast cancer screening at 10 UK National Health Service Breast Screening Units from 1996 to 1998 joined the Million Women Study by completing a questionnaire before screening and were followed for their screening outcome. Results Overall, 399 (0.5%) participants were diagnosed with breast cancer and 2,629 (3.0%) had false positive recall. Compared to never users of HRT, the adjusted relative risk (95% CI) of false positive recall was: 1.62 (1.43–1.83), 1.80 (1.62–2.01) and 0.76 (0.52–1.10) in current users of oestrogen-only HRT, oestrogen-progestagen HRT and tibolone, respectively (p (heterogeneity) < 0.0001); 1.65 (1.43–1.91), 1.49 (1.22–1.81) and 2.11 (1.45–3.07) for current HRT used orally, transdermally or via an implant, respectively (p (heterogeneity) = 0.2); and 1.84 (1.67–2.04) and 1.75 (1.49–2.06) for sequential and continuous oestrogen-progestagen HRT, respectively (p (heterogeneity) = 0.6). The relative risk of false positive recall among current users appeared to increase with increasing time since menopause, but did not vary significantly according to any other factors examined, including duration of use, hormonal constituents, dose, whether single- or two-view screening was used, or the woman's personal characteristics. Conclusion Current use of oestrogen-only and oestrogen-progestagen HRT, but not tibolone, increases the risk of false positive recall at screening. PMID:16417651
Mahfouz, Ayman; Naji, Meeran; Mok, Wing Yan; Taghi, Ali S; Win, Zarni
2015-09-01
A false-positive uptake of F18-fluorodeoxyglucose (FDG) on positron-emission tomography/computed tomography (PET/CT) can result in confusion and misinterpretation of scans. Such uptakes have been previously described after injection of polytetrafluoroethylene (Teflon) into the vocal folds. Similarly, vocal fold injection of silicone elastomer (Silastic) can result not only in a false-positive FDG uptake on PET/CT, but also in chronic inflammation. We report a case of increased FDG uptake in a vocal fold after Silastic injection that was misinterpreted as a malignancy in a 70-year-old woman who had metastatic carcinoma of the stomach.
HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites
Kosack, Cara S.; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng’ang’a, Anne; Andre, Bita; Zahinda, Jean-Paul BN; Fransen, Katrien; Page, Anne-Laure
2017-01-01
Abstract Introduction: We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. Methods: In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Results: Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. Conclusions: The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy. PMID:28691437
HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites.
Kosack, Cara S; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng'ang'a, Anne; Andre, Bita; Zahinda, Jean-Paul Bn; Fransen, Katrien; Page, Anne-Laure
2017-07-03
We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy.
DOT National Transportation Integrated Search
1974-05-01
A resting 'normal' ECG can coexist with known angina pectoris, positive angiocardiography and previous myocardial infarction. In contemporary exercise ECG tests, a false positive/false negative total error of 10% is not unusual. Research aimed at imp...
Finkelstein's test: a descriptive error that can produce a false positive.
Elliott, B G
1992-08-01
Over the last three decades an error in performing Finkelstein's test has crept into the English literature in both text books and journals. This error can produce a false-positive, and if relied upon, a wrong diagnosis can be made, leading to inappropriate surgery.
A Demonstration of Regression False Positive Selection in Data Mining
ERIC Educational Resources Information Center
Pinder, Jonathan P.
2014-01-01
Business analytics courses, such as marketing research, data mining, forecasting, and advanced financial modeling, have substantial predictive modeling components. The predictive modeling in these courses requires students to estimate and test many linear regressions. As a result, false positive variable selection ("type I errors") is…
Nigro, Olivia D; Steward, Grieg F
2015-04-01
Plating environmental samples on vibrio-selective chromogenic media is a commonly used technique that allows one to quickly estimate concentrations of putative vibrio pathogens or to isolate them for further study. Although this approach is convenient, its usefulness depends directly on how well the procedure selects against false positives. We tested whether a chromogenic medium, CHROMagar Vibrio (CaV), used alone (single-plating) or in combination (double-plating) with a traditional medium thiosulfate-citrate-bile-salts (TCBS), could improve the discrimination among three pathogenic vibrio species (Vibrio cholerae, Vibrio parahaemolyticus, and Vibrio vulnificus) and thereby decrease the number of false-positive colonies that must be screened by molecular methods. Assays were conducted on water samples from two estuarine environments (one subtropical, one tropical) in a variety of seasonal conditions. The results of the double-plating method were confirmed by PCR and 16S rRNA sequencing. Our data indicate that there is no significant difference in the false-positive rate between CaV and TCBS when using a single-plating technique, but determining color changes on the two media sequentially (double-plating) reduced the rate of false positive identification in most cases. The improvement achieved was about two-fold on average, but varied greatly (from 0- to 5-fold) and depended on the sampling time and location. The double-plating method was most effective for V. vulnificus in warm months, when overall V. vulnificus abundance is high (false positive rates as low as 2%, n=178). Similar results were obtained for V. cholerae (minimum false positive rate of 16%, n=146). In contrast, the false positive rate for V. parahaemolyticus was always high (minimum of 59%, n=109). Sequence analysis of false-positive isolates indicated that the majority of confounding isolates are from the Vibrionaceae family, however, members of distantly related bacterial groups were also able to grow on vibrio-selective media, even when using the double-plating method. In conclusion, the double-plating assay is a simple means to increase the efficiency of identifying pathogenic vibrios in aquatic environments and to reduce the number of molecular assays required for identity confirmation. However, the high spatial and temporal variability in the performance of the media mean that molecular approaches are still essential to obtain the most accurate vibrio abundance estimates from environmental samples. Copyright © 2015 Elsevier B.V. All rights reserved.
The effect of mood on false memory for emotional DRM word lists.
Zhang, Weiwei; Gross, Julien; Hayne, Harlene
2017-04-01
In the present study, we investigated the effect of participants' mood on true and false memories of emotional word lists in the Deese-Roediger-McDermott (DRM) paradigm. In Experiment 1, we constructed DRM word lists in which all the studied words and corresponding critical lures reflected a specified emotional valence. In Experiment 2, we used these lists to assess mood-congruent true and false memory. Participants were randomly assigned to one of three induced-mood conditions (positive, negative, or neutral) and were presented with word lists comprised of positive, negative, or neutral words. For both true and false memory, there was a mood-congruent effect in the negative mood condition; this effect was due to a decrease in true and false recognition of the positive and neutral words. These findings are consistent with both spreading-activation and fuzzy-trace theories of DRM performance and have practical implications for our understanding of the effect of mood on memory.
Use of the false discovery rate for evaluating clinical safety data.
Mehrotra, Devan V; Heyse, Joseph F
2004-06-01
Clinical adverse experience (AE) data are routinely evaluated using between group P values for every AE encountered within each of several body systems. If the P values are reported and interpreted without multiplicity considerations, there is a potential for an excess of false positive findings. Procedures based on confidence interval estimates of treatment effects have the same potential for false positive findings as P value methods. Excess false positive findings can needlessly complicate the safety profile of a safe drug or vaccine. Accordingly, we propose a novel method for addressing multiplicity in the evaluation of adverse experience data arising in clinical trial settings. The method involves a two-step application of adjusted P values based on the Benjamini and Hochberg false discovery rate (FDR). Data from three moderate to large vaccine trials are used to illustrate our proposed 'Double FDR' approach, and to reinforce the potential impact of failing to account for multiplicity. This work was in collaboration with the late Professor John W. Tukey who coined the term 'Double FDR'.
Rahal, M; Kervaire, B; Villard, J; Tiercy, J-M
2008-03-01
Human leukocyte antigen (HLA) typing by polymerase chain reaction-sequence-specific oligonucleotide (PCR-SSO) hybridization on solid phase (microbead assay) or polymerase chain reaction-sequence-specific primers (PCR-SSP) requires interpretation softwares to detect all possible allele combinations. These programs propose allele calls by taking into account false-positive or false-negative signal(s). The laboratory has the option to validate typing results in the presence of strongly cross-reacting or apparent false-negative signals. Alternatively, these seemingly aberrant signals may disclose novel variants. We report here four new HLA-B (B*5620 and B*5716) and HLA-DRB1 alleles (DRB1*110107 and DRB1*1474) that were detected by apparent false-negative or -positive hybridization or amplification patterns, and ultimately resolved by sequencing. To avoid allele misassignments, a comprehensive evaluation of acquired data as documented in a quality assurance system is therefore required to confirm unambiguous typing interpretation.
A hybrid protection approaches for denial of service (DoS) attacks in wireless sensor networks
NASA Astrophysics Data System (ADS)
Gunasekaran, Mahalakshmi; Periakaruppan, Subathra
2017-06-01
Wireless sensor network (WSN) contains the distributed autonomous devices with the sensing capability of physical and environmental conditions. During the clustering operation, the consumption of more energy causes the draining in battery power that leads to minimum network lifetime. Hence, the WSN devices are initially operated on low-power sleep mode to maximise the lifetime. But, the attacks arrival cause the disruption in low-power operating called denial of service (DoS) attacks. The conventional intrusion detection (ID) approaches such as rule-based and anomaly-based methods effectively detect the DoS attacks. But, the energy consumption and false detection rate are more. The absence of attack information and broadcast of its impact to the other cluster head (CH) leads to easy DoS attacks arrival. This article combines the isolation and routing tables to detect the attack in the specific cluster and broadcasts the information to other CH. The intercommunication between the CHs prevents the DoS attacks effectively. In addition, the swarm-based defence approach is proposed to migrate the fault channel to normal operating channel through frequency hop approaches. The comparative analysis between the proposed table-based intrusion detection systems (IDSs) and swarm-based defence approaches with the traditional IDS regarding the parameters of transmission overhead/efficiency, energy consumption, and false positive/negative rates proves the capability of DoS prediction/prevention in WSN.
Dalquen, P; Rashed, B; Hinsch, A; Issa, R; Clauditz, T; Luebke, A; Lüttges, J; Saeger, W; Bohuslavizki, K H
2016-09-01
Diagnostic problems of thyroid cytology are frequently discussed, but relevance and causes of discrepant cytological and histological diagnoses are rarely studied in detail. Investigation of causes and relevance of discrepant diagnoses. The analysis includes 297 patients who had thyroid resection after prior fine needle aspiration (FNA) and is based on the cytological and histological reports. In special cases, cytological and histological specimens were re-examined. Malignant tumors were found in 45 patients (15.1 %). In 5 patients the cytological diagnosis was "false negative". Three of these 5 tumors were papillary carcinomas (PTC) of ≤10 mm, one an obviously nonmalignant papillary proliferation of the thyroidal epithelium and one a malignant lymphoma complicating autoimmune thyreoiditis (AIT). In 11 of the 35 patients with a FNA diagnosis "suspicious of malignancy" or "malignant," 1 AIT, 4 goiter nodules, and 6 adenomas were diagnosed histologically. However, since distinct nuclear atypia was found in three of five false positive diagnoses, there still remains doubt in their benignity. Carcinomas of ≤10 mm incidentally detected in the resected thyroid tissue may not be relevant to the patient and do not reduce the high negative predictive value of FNA. The final diagnosis on the resected tissue should include the cytological findings. Discrepant findings should be commented in the report to the clinician.
Glanders and the risk for its introduction through the international movement of horses.
Kettle, A N B; Wernery, U
2016-09-01
Glanders is the contagious zoonotic disease caused by infection with Burkholderia mallei. It affects primarily horses, donkeys and mules. The disease was eradicated from large areas of the Western world in the early 20th century, but, over the last 10-20 years, has emerged and re-emerged in areas in which it was previously unknown or had been eradicated. Although glanders was previously thought to manifest in only acute or chronic presentations, it now appears that B. mallei can produce latent infections similar to those caused by Burkholderia pseudomallei. These latent infections may or may not be detectable by current diagnostic tests. The diagnostic test currently recommended by the World Organisation for Animal Health (Office International des Epizooties [OIE]) for international trade in equids is the complement fixation test (CFT). This test has been shown to have varying sensitivities and specificities depending on the antigen and methodology used. False positives are problematic for the horse-owner and veterinary authority, whereas false negatives may allow the reintroduction of B. mallei into B. mallei-free areas. These gaps in knowledge of the epidemiology of glanders, and weaknesses in its diagnosis, coupled with the increased movement of equids, indicate that infection with B. mallei remains a major risk in the context of international movement of equids. © 2016 EVJ Ltd.
Are false-positive rates leading to an overestimation of noise-induced hearing loss?
Schlauch, Robert S; Carney, Edward
2011-04-01
To estimate false-positive rates for rules proposed to identify early noise-induced hearing loss (NIHL) using the presence of notches in audiograms. Audiograms collected from school-age children in a national survey of health and nutrition (the Third National Health and Nutrition Examination Survey [NHANES III]; National Center for Health Statistics, 1994) were examined using published rules for identifying noise notches at various pass-fail criteria. These results were compared with computer-simulated "flat" audiograms. The proportion of these identified as having a noise notch is an estimate of the false-positive rate for a particular rule. Audiograms from the NHANES III for children 6-11 years of age yielded notched audiograms at rates consistent with simulations, suggesting that this group does not have significant NIHL. Further, pass-fail criteria for rules suggested by expert clinicians, applied to NHANES III audiometric data, yielded unacceptably high false-positive rates. Computer simulations provide an effective method for estimating false-positive rates for protocols used to identify notched audiograms. Audiometric precision could possibly be improved by (a) eliminating systematic calibration errors, including a possible problem with reference levels for TDH-style earphones; (b) repeating and averaging threshold measurements; and (c) using earphones that yield lower variability for 6.0 and 8.0 kHz--2 frequencies critical for identifying noise notches.
False-positive cancer screens and health-related quality of life.
McGovern, Patricia M; Gross, Cynthia R; Krueger, Richard A; Engelhard, Deborah A; Cordes, Jill E; Church, Timothy R
2004-01-01
By design, screening tests are imperfect-unresponsive to some cancers (false negatives) while occasionally raising suspicion of cancer where none exists (false positives). This pilot study describes patients' responses to having a false-positive screening test for cancer, and identifies screening effects on health-related quality of life (HRQoL). The pilot findings suggest issues important for incorporation in future evaluations of the impact of screening for prostate, lung, colon, or ovarian (PLCO) cancers. Seven focus groups were conducted to identify the nature and meaning of all phases of PLCO screening. Minnesota participants in the Prostate, Lung, Colorectal and Ovarian Cancer Screening Trial who had completed screening, with at least 1 false-positive screen, participated (N = 47). Participants' reactions to abnormal screens and diagnostic work-ups were primarily emotional (eg, anxiety and distress), not physical, and ultimately positive for the majority. Health distress and fear of cancer and death were the major negative aspects of HRQoL identified. These concepts are not typically included in generic HRQoL questionnaires like the SF-36, but are highly relevant to PLCO screening. Clinicians were regarded as underestimating the discomfort of follow-up diagnostic testing. However, relief and assurance appeared to eventually outweigh the negative emotions for most participants. Implications for oncology nurses include the need to consider the emotional consequences of screening in association with screen reliability and validity.
Comparison of scanty AFB smears against culture in an area with high HIV prevalence.
Lawson, L; Yassin, M A; Ramsay, A; Emenyonu, N E; Squire, S B; Cuevas, L E
2005-08-01
To verify among tuberculosis (TB) suspects attending hospitals in Abuja, Nigeria, if sputum smears graded as scanty are false-positive, sputum smears from 1068 patients were graded with the International Union Against Tuberculosis and Lung Disease classification. One specimen was cultured. Eight hundred and twenty-four (26%) smears were positive, 137 (4%) scanty and 2243 negative. Of 1068 cultures, 680 (64%) were positive. One hundred and thirty (95%) scanty and 809 (98%) positive smears were culture-positive. Twelve of 18 patients with a single scanty smear and 51 of 52 with > or = 2 scanty smears were culture-positive. Fewer than < 5% scanty results, < 1% of the patients treated for TB, are false-positive.
Potential for false positive HIV test results with the serial rapid HIV testing algorithm.
Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K
2012-03-19
Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.
Potential for false positive HIV test results with the serial rapid HIV testing algorithm
2012-01-01
Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals. PMID:22429706
Prediction-Oriented Marker Selection (PROMISE): With Application to High-Dimensional Regression.
Kim, Soyeon; Baladandayuthapani, Veerabhadran; Lee, J Jack
2017-06-01
In personalized medicine, biomarkers are used to select therapies with the highest likelihood of success based on an individual patient's biomarker/genomic profile. Two goals are to choose important biomarkers that accurately predict treatment outcomes and to cull unimportant biomarkers to reduce the cost of biological and clinical verifications. These goals are challenging due to the high dimensionality of genomic data. Variable selection methods based on penalized regression (e.g., the lasso and elastic net) have yielded promising results. However, selecting the right amount of penalization is critical to simultaneously achieving these two goals. Standard approaches based on cross-validation (CV) typically provide high prediction accuracy with high true positive rates but at the cost of too many false positives. Alternatively, stability selection (SS) controls the number of false positives, but at the cost of yielding too few true positives. To circumvent these issues, we propose prediction-oriented marker selection (PROMISE), which combines SS with CV to conflate the advantages of both methods. Our application of PROMISE with the lasso and elastic net in data analysis shows that, compared to CV, PROMISE produces sparse solutions, few false positives, and small type I + type II error, and maintains good prediction accuracy, with a marginal decrease in the true positive rates. Compared to SS, PROMISE offers better prediction accuracy and true positive rates. In summary, PROMISE can be applied in many fields to select regularization parameters when the goals are to minimize false positives and maximize prediction accuracy.
False Memories for Affective Information in Schizophrenia.
Fairfield, Beth; Altamura, Mario; Padalino, Flavia A; Balzotti, Angela; Di Domenico, Alberto; Mammarella, Nicola
2016-01-01
Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the to-be-remembered material and false memory occurrence has not yet been studied. In this study, 24 patients and 24 healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative, or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls ( p < 0.05) when remembering episodes with positive or negative outcomes. The effect of valence was apparent in the patient group. For example, it did not affect the production causal false memories ( p > 0.05) resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e., neutral episodes yielded a higher degree of errors than positive and negative episodes). Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved.
False Memories for Affective Information in Schizophrenia
Fairfield, Beth; Altamura, Mario; Padalino, Flavia A.; Balzotti, Angela; Di Domenico, Alberto; Mammarella, Nicola
2016-01-01
Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the to-be-remembered material and false memory occurrence has not yet been studied. In this study, 24 patients and 24 healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative, or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls (p < 0.05) when remembering episodes with positive or negative outcomes. The effect of valence was apparent in the patient group. For example, it did not affect the production causal false memories (p > 0.05) resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e., neutral episodes yielded a higher degree of errors than positive and negative episodes). Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved. PMID:27965600
False positive computed tomographic angiography for Stanford type A aortic dissection.
Bandali, Murad F; Hatem, Muhammed A; Appoo, Jehangir J; Hutchison, Stuart J; Wong, Jason K
2015-12-01
Computed tomographic angiography (CTA) has emerged as the defacto imaging test to rule out acute aortic dissection; however, it is not without flaws. We report a case of a false-positive CTA with respect to Stanford Type A aortic dissection. A 52 year-old male presented with sudden onset shortness of breath. He denied chest pain. Due to severe hypertension and an Emergency Department bedside ultrasound suggesting an intimal flap in the aorta, CTA was requested to better assess the ascending aorta and was interpreted as consistent with Stanford Type A aortic dissection with thrombosis of the false lumen in the ascending aorta. However, intra-operative imaging (TEE and epi-aortic scanning) did not identify an intimal flap or dissection, and neither did definitive surgical inspection of the aorta. The suspected aortic dissection and thrombosed false lumen were not visualized on repeat CTA two days later. False positive diagnosis of Stanford Type A aortic dissection on CTA can be the result of technical factors, streak artifacts, motion artifacts, and periaortic structures. In this case, non-uniform arterial contrast enhancement secondary to unrecognized biventricular dysfunction resulted in the false positive CTA appearance of an intimal flap and mural thrombus. Intra-operative TEE and epi-aortic scanning were proven correct in excluding aortic dissection by the standard of definitive surgical inspection of the aorta.
Wang, Yuexia; Yang, Ming; Liu, Shuchun; Chen, Wanyi; Suo, Biao
2015-09-01
Real-time polymerase chain reaction (PCR) allows rapid detection of Salmonella in frozen dairy products, but it might cause a false positive detection result because it might amplify DNA from dead target cells as well. In this study, Salmonella-free frozen ice cream was initially inoculated with heat-killed Salmonella Typhimurium cells and stored at -18°C. Bacterial DNA extracted from the sample was amplified using TaqMan probe-based real-time PCR targeting the invA gene. Our results indicated that DNA from the dead cells remained stable in frozen ice cream for at least 20 days, and could produce fluorescence signal for real-time PCR as well. To overcome this limitation, propidium monoazide (PMA) was combined with real-time PCR. PMA treatment can effectively prevent PCR amplification from heat-killed Salmonella cells in frozen ice cream. The PMA real-time PCR assay can selectively detect viable Salmonella at as low as 10 3 CFU/mL. Combining 18 hours of pre-enrichment with the assay allows for the detection of viable Salmonella at 10 0 CFU/mL and avoiding the false-positive result of dead cells. The PMA real-time PCR assay provides an alternative specifically for detection of viable Salmonella in ice cream. However, when the PMA real-time PCR assay was evaluated in ice cream subjected to frozen storage, it obviously underestimated the contamination situation of viable Salmonella, which might lead to a false negative result. According to this result, the use of enrichment prior to PMA real-time PCR analysis remains as the more appropriate approach. Copyright © 2015. Published by Elsevier B.V.
Kaufmann, A; Maden, K; Leisser, W; Matera, M; Gude, T
2005-11-01
Inorganic polyphosphates (di-, tri- and higher polyphosphates) can be used to treat fish, fish fillets and shrimps in order to improve their water-binding capacity. The practical relevance of this treatment is a significant gain of weight caused by the retention/uptake of water and natural juice into the fish tissues. This practice is legal; however, the use of phosphates has to be declared. The routine control testing of fish for the presence of polyphosphates, produced some results that were difficult to explain. One of the two analytical methods used determined low diphosphate concentrations in a number of untreated samples, while the other ion chromatography (IC) method did not detect them. This initiated a number of investigations: results showed that polyphosphates in fish and shrimps tissue undergo a rapid enzymatic degradation, producing the ubiquitous orthophosphate. This led to the conclusion that sensitive analytical methods are required in order to detect previous polyphosphate treatment of a sample. The polyphosphate concentrations detected by one of the analytical methods could not be explained by the degradation of endogenous high-energy nucleotides like ATP into diphosphate, but by a coeluting compound. Further investigations by LC-MS-MS proved that the substance responsible for the observed peak was inosine monophsosphate (IMP) and not as thought the inorganic diphosphate. The method producing the false-positive result was modified and both methods were ultimately able to detect polyphosphates well separated from natural nucleotides. Polyphosphates could no longer be detected (<0.5 mg kg-1) after modification of the analytical methodology. The relevance of these findings lies in the fact that similar analytical methods are employed in various control laboratories, which might lead to false interpretation of measurements.
Neonatal respiratory distress syndrome: Chest X-ray or lung ultrasound? A systematic review
Culpan, Anne-Marie; Watts, Catriona; Munyombwe, Theresa; Wolstenhulme, Stephen
2017-01-01
Background and aim Neonatal respiratory distress syndrome is a leading cause of morbidity in preterm new-born babies (<37 weeks gestation age). The current diagnostic reference standard includes clinical testing and chest radiography with associated exposure to ionising radiation. The aim of this review was to compare the diagnostic accuracy of lung ultrasound against the reference standard in symptomatic neonates of ≤42 weeks gestation age. Methods A systematic search of literature published between 1990 and 2016 identified 803 potentially relevant studies. Six studies met the review inclusion criteria and were retrieved for analysis. Quality assessment was performed before data extraction and meta-analysis. Results Four prospective cohort studies and two case control studies included 480 neonates. All studies were of moderate methodological quality although heterogeneity was evident across the studies. The pooled sensitivity and specificity of lung ultrasound were 97% (95% confidence interval [CI] 94–99%) and 91% (CI: 86–95%) respectively. False positive diagnoses were made in 16 cases due to pneumonia (n = 8), transient tachypnoea (n = 3), pneumothorax (n = 1) and meconium aspiration syndrome (n = 1); the diagnoses of the remaining three false positive results were not specified. False negatives diagnoses occurred in nine cases, only two were specified as air-leak syndromes. Conclusions Lung ultrasound was highly sensitive for the detection of neonatal respiratory distress syndrome although there is potential to miss co-morbid air-leak syndromes. Further research into lung ultrasound diagnostic accuracy for neonatal air-leak syndrome and economic modelling for service integration is required before lung ultrasound can replace chest radiography as the imaging component of the reference standard. PMID:28567102
Cushing's Syndrome: Where and How to Find It.
Debono, Miguel; Newell-Price, John D
2016-01-01
The diagnosis of Cushing's syndrome is challenging to endocrinologists as patients often present with an insidious history, together with subtle external clinical features. Moreover, complications of endogenous hypercortisolism, such as visceral obesity, diabetes, hypertension and osteoporosis, are conditions commonly found in the population, and discerning whether these are truly a consequence of hypercortisolism is not straightforward. To avoid misdiagnosis, a careful investigative approach is essential. The investigation of Cushing's syndrome is a three-step process. Firstly, after exclusion of exogenous glucocorticoid use, the decision to initiate investigations should be based on whether there is a clinical index of suspicion of the disease. Specific signs of endogenous hypercortisolism raise the a priori probability of a truly positive test. Secondly, if the probability of hypercortisolism is high, one should carry out specific tests as indicated by Endocrine Society guidelines. Populations with non-distinguishing features of Cushing's syndrome should not be screened routinely as biochemical tests have a high false-positive rate if used indiscriminately. Thirdly, once hypercortisolism is confirmed, one should move to establish the cause. This usually entails distinguishing between adrenal or pituitary-related causes and the remoter possibility of the ectopic adrenocorticotropic hormone syndrome. It is crucial that the presence of Cushing's syndrome is established before any attempt at differential diagnosis. © 2016 S. Karger AG, Basel.
Shanks, Leslie; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Pirou, Erwan; Ritmeijer, Koert; Masiga, Johnson; Abebe, Almaz
2015-02-03
In Ethiopia a tiebreaker algorithm using 3 rapid diagnostic tests (RDTs) in series is used to diagnose HIV. Discordant results between the first 2 RDTs are resolved by a third 'tiebreaker' RDT. Médecins Sans Frontières uses an alternate serial algorithm of 2 RDTs followed by a confirmation test for all double positive RDT results. The primary objective was to compare the performance of the tiebreaker algorithm with a serial algorithm, and to evaluate the addition of a confirmation test to both algorithms. A secondary objective looked at the positive predictive value (PPV) of weakly reactive test lines. The study was conducted in two HIV testing sites in Ethiopia. Study participants were recruited sequentially until 200 positive samples were reached. Each sample was re-tested in the laboratory on the 3 RDTs and on a simple to use confirmation test, the Orgenics Immunocomb Combfirm® (OIC). The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. 2620 subjects were included with a HIV prevalence of 7.7%. Each of the 3 RDTs had an individual specificity of at least 99%. The serial algorithm with 2 RDTs had a single false positive result (1 out of 204) to give a PPV of 99.5% (95% CI 97.3%-100%). The tiebreaker algorithm resulted in 16 false positive results (PPV 92.7%, 95% CI: 88.4%-95.8%). Adding the OIC confirmation test to either algorithm eliminated the false positives. All the false positives had at least one weakly reactive test line in the algorithm. The PPV of weakly reacting RDTs was significantly lower than those with strongly positive test lines. The risk of false positive HIV diagnosis in a tiebreaker algorithm is significant. We recommend abandoning the tie-breaker algorithm in favour of WHO recommended serial or parallel algorithms, interpreting weakly reactive test lines as indeterminate results requiring further testing except in the setting of blood transfusion, and most importantly, adding a confirmation test to the RDT algorithm. It is now time to focus research efforts on how best to translate this knowledge into practice at the field level. Clinical Trial registration #: NCT01716299.
Applying a CAD-generated imaging marker to assess short-term breast cancer risk
NASA Astrophysics Data System (ADS)
Mirniaharikandehei, Seyedehnafiseh; Zarafshani, Ali; Heidari, Morteza; Wang, Yunzhi; Aghaei, Faranak; Zheng, Bin
2018-02-01
Although whether using computer-aided detection (CAD) helps improve radiologists' performance in reading and interpreting mammograms is controversy due to higher false-positive detection rates, objective of this study is to investigate and test a new hypothesis that CAD-generated false-positives, in particular, the bilateral summation of false-positives, is a potential imaging marker associated with short-term breast cancer risk. An image dataset involving negative screening mammograms acquired from 1,044 women was retrospectively assembled. Each case involves 4 images of craniocaudal (CC) and mediolateral oblique (MLO) view of the left and right breasts. In the next subsequent mammography screening, 402 cases were positive for cancer detected and 642 remained negative. A CAD scheme was applied to process all "prior" negative mammograms. Some features from CAD scheme were extracted, which include detection seeds, the total number of false-positive regions, an average of detection scores and the sum of detection scores in CC and MLO view images. Then the features computed from two bilateral images of left and right breasts from either CC or MLO view were combined. In order to predict the likelihood of each testing case being positive in the next subsequent screening, two logistic regression models were trained and tested using a leave-one-case-out based cross-validation method. Data analysis demonstrated the maximum prediction accuracy with an area under a ROC curve of AUC=0.65+/-0.017 and the maximum adjusted odds ratio of 4.49 with a 95% confidence interval of [2.95, 6.83]. The results also illustrated an increasing trend in the adjusted odds ratio and risk prediction scores (p<0.01). Thus, the study showed that CAD-generated false-positives might provide a new quantitative imaging marker to help assess short-term breast cancer risk.
Looking for Childhood Schizophrenia: Case Series of False Positives.
ERIC Educational Resources Information Center
Stayer, Catherine; Sporn, Alexandra; Gogtay, Nitin; Tossell, Julia; Lenane, Marge; Gochman, Peter; Rapoport, Judith L.
2004-01-01
Extensive experience with the diagnosis of childhood-onset schizophrenia indicates a high rate of false positives. Most mislabeled patients have chronic disabling, affective, or behavioral disorders. The authors report the cases of three children who passed stringent initial childhood-onset schizophrenia "screens" but had no chronic psychotic…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Jared M; Ferber, Aaron E; Greenlee, Elliot D
Akatosh is a highly configurable system based on the integration of the capabilities of one or more Intrusion Detection Systems (IDS) and automated forensic analysis. Akatosh reduces the false positive rates of IDSs and alleviates costs of incident response by pointing forensic personnel to the root cause of an incident on affected endpoint devices. Akatosh is able to analyze a computer system in near real-time and provide operations and forensic analyst personnel with continuous feedback on the impact of malware and software on deployed systems. Additionally, Akatosh provides the ability to look back into any prior state in the historymore » of the computer system along with the ability to compare one or more prior system states with any other prior state.« less
Hypertensive emergency masquerading as phaeochromocytoma: a report of two cases.
Hulkower, Raphael; Gubbi, Sriram; Meholli, Mimoza; Schubart, Ulrich
2017-08-07
We report two cases of patients who were hospitalised for hypertensive emergency. In both cases, laboratory testing during admission revealed elevated normetanephrines in the range of 4-5 times the upper limit of normal using liquid chromatography with mass spectrometry. Imaging studies did not localise any phaeochromocytoma or paraganglioma (PPGL). Repeat biochemical testing after discharge was within normal limits in both cases. These observations suggest that hypertensive emergency should be recognised as a potential cause of 'false-positive' laboratory findings in the diagnostic assessment for PPGL. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Antidepressants and testicular cancer: cause versus association.
Andrade, Chittaranjan
2014-03-01
A data mining study that examined associations between 105 drugs and 55 cancer sites found significant associations between 2 selective serotonin reuptake inhibitors (fluoxetine and paroxetine) and testicular cancer. The study suggested several reasons why these associations merited further investigation. A later study tested specific relationships between 12 antidepressant drugs and testicular cancer and subtypes thereof; whereas significant relationships were again found, these disappeared after adjusting for confounding variables. These 2 studies are educative because they illustrate how false-positive results can easily arise in exploratory research and how confounding may be responsible for statistically significant relationships in study designs that are not randomized controlled trials. © Copyright 2014 Physicians Postgraduate Press, Inc.
Hepatic radiation injury mimicking metastasis in distal esophageal cancer.
Demey, Karel; Van Veer, Hans; Nafteux, Philippe; Deroose, Christophe M; Haustermans, Karin; Coolen, Johan; Vandecaveye, Vincent; Coosemans, Willy; Van Cutsem, Eric
2017-08-01
A new hypermetabolic lesion on 18 FDG-PET/CT after neo-adjuvant chemoradiotherapy for distal esophageal cancer can be a hepatic metastasis and should be examined carefully before esophagectomy. We present a case of acute and nodular radiation-induced injury of the left liver after neo-adjuvant chemoradiotherapy for distal esophageal cancer, which resembles a hepatic metastasis on 18 FDG-PET/CT. Acute and nodular radiation hepatitis (RH) can be a potential cause of false-positive findings of malignancy and therefore exclude patients who could benefit from esophagectomy. 18 FDG-PET/CT images should therefore carefully be interpreted and compared with the radiation beams, dose distribution and eventually clarified by DW-MR imaging.
Domínguez Hernández, Karem R.; Aguilar Lasserre, Alberto A.; Posada Gómez, Rubén; Palet Guzmán, José A.; González Sánchez, Blanca E.
2013-01-01
Cervical cancer is the second largest cause of death among women worldwide. Nowadays, this disease is preventable and curable at low cost and low risk when an accurate diagnosis is done in due time, since it is the neoplasm with the highest prevention potential. This work describes the development of an expert system able to provide a diagnosis to cervical neoplasia (CN) precursor injuries through the integration of fuzzy logics and image interpretation techniques. The key contribution of this research focuses on atypical cases, specifically on atypical glandular cells (AGC). The expert system consists of 3 phases: (1) risk diagnosis which consists of the interpretation of a patient's clinical background and the risks for contracting CN according to specialists; (2) cytology images detection which consists of image interpretation (IM) and the Bethesda system for cytology interpretation, and (3) determination of cancer precursor injuries which consists of in retrieving the information from the prior phases and integrating the expert system by means of a fuzzy logics (FL) model. During the validation stage of the system, 21 already diagnosed cases were tested with a positive correlation in which 100% effectiveness was obtained. The main contribution of this work relies on the reduction of false positives and false negatives by providing a more accurate diagnosis for CN. PMID:23690881
McAuliffe, Gary N; Taylor, Susan L; Drinković, Dragana; Roberts, Sally A; Wilson, Elizabeth M; Best, Emma J
2018-01-01
In July 2014, New Zealand introduced universal infant vaccination with RotaTeq (Merk & Co.) administered as 3 doses at 6 weeks, 3 and 5 months of age. We sought to assess the impact of rotavirus vaccination on gastroenteritis (GE) hospitalizations in the greater Auckland region and analyze changes in rotavirus testing in the period around vaccine introduction. Hospitalizations, laboratory testing rates and methods were compared between the pre-vaccine period (2009-2013), post-vaccine period (January 2015 to December 2015) and year of vaccine introduction (2014). There was a 68% decline in rotavirus hospitalizations of children <5 years of age after vaccine introduction (from 258/100,000 to 83/100,000) and a 17% decline in all-cause gastroenteritis admissions (from 1815/100,000 to 1293/100,000). Reductions were also seen in pediatric groups too old to have received vaccine. Despite these changes, rotavirus testing rates in our region remained static in the year after vaccine introduction compared with the 2 prior years, and after vaccine introduction, we observed a high rate of false positives 19/58 (33%) in patients with reactive rotavirus tests. Rotavirus vaccine has had a significant early impact on gastroenteritis hospitalizations for children in the Auckland region. However, continued rotavirus testing at pre-vaccine rates risks generating false positive results. Laboratories and clinicians should consider reviewing their testing algorithms before vaccine introduction.
Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young
2008-08-01
We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.
Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho
2014-01-01
Background: This study was conducted to evaluate the diagnostic validity of the 13C-urea breath test (13C-UBT) in the remnant stomach after partial gastrectomy for gastric cancer. Methods: The 13C-UBT results after Helicobacter pylori eradication therapy was compared with the results of endoscopic biopsy-based methods in the patients who have received partial gastrectomy for the gastric cancer. Results: Among the gastrectomized patients who showed the positive 13C-UBT results (≥ 2.5‰, n = 47) and negative 13C-UBT results (< 2.5‰, n = 114) after H. pylori eradication, 26 patients (16.1%) and 4 patients (2.5%) were found to show false positive and false negative results based on biopsy-based methods, respectively. The sensitivity, specificity, false positive rate, and false negative rate for the cut-off value of 2.5‰ were 84.0%, 80.9%, 19.1%, and 16.0%, respectively. The positive and negative predictive values were 44.7% and 96.5%, respectively. In the multivariate analysis, two or more H. pylori eradication therapies (odds ratio = 3.248, 95% confidence interval= 1.088–9.695, P = 0.035) was associated with a false positive result of the 13C-UBT. Conclusions: After partial gastrectomy, a discordant result was shown in the positive 13C-UBT results compared to the endoscopic biopsy methods for confirming the H. pylori status after eradication. Additional endoscopic biopsy-based H. pylori tests would be helpful to avoid unnecessary treatment for H. pylori eradication in these cases. PMID:25574466
Exploring the cause of initially reactive bovine brains on rapid tests for BSE
Dudas, Sandor; James, Jace; Anderson, Renee; Czub, Stefanie
2015-01-01
ABSTRACT Bovine spongiform encephalopathy (BSE) is an invariably fatal prion disease of cattle. The identification of the zoonotic potential of BSE prompted safety officials to initiate surveillance testing for this disease. In Canada, BSE surveillance is primarily focused on high risk cattle including animals which are dead, down and unable to rise, diseased or distressed. This targeted surveillance results in the submission of brain samples with a wide range of tissue autolysis and associated contaminants. These contaminants have the potential to interfere with important steps of surveillance tests resulting in initially positive test results requiring additional testing to confirm the disease status of the animal. The current tests used for BSE screening in Canada utilize the relative protease resistance of the prion protein gained when it misfolds from PrPC to PrPSc as part of the disease process. Proteinase K completely digests PrPC in normal brains, but leaves most of the PrPSc in BSE positive brains intact which is detected using anti-prion antibodies. These tests are highly reliable but occasionally give rise to initially reactive/false positive results. Test results for these reactive samples were close to the positive/negative cut-off on a sub set of test platforms. This is in contrast to all of the previous Canadian positive samples whose numeric values on these same test platforms were 10 to 100 fold greater than the test positive/negative cut-off. Here we explore the potential reason why a sample is repeatedly positive on a sub-set of rapid surveillance tests, but negative on other test platforms. In order to better understand and identify what might cause these initial reactions, we have conducted a variety of rapid and confirmatory assays as well as bacterial isolation and identification on BSE positive, negative and initially reactive samples. We observed high levels of viable bacterial contamination in initially reactive samples suggesting that the reactivity may be related to bacterial factors. Several bacteria isolated from the initially reactive samples have characteristics of biofilm forming bacteria and this extracellular matrix might play a role in preventing complete digestion of PrPC in these samples. PMID:26689488
Development and Implementation of Metrics for Identifying Military Impulse Noise
2010-09-01
False Negative Rate FP False Positive FPR False Positive Rate FtC Fort Carson, CO GIS Geographic Information System GMM Gaussian mixture model Hz...60 70 80 90 100 110 Bin Number B in N um be r N um ber of D ata Points M apped to B in 14 Figure 8. Plot of typical neuron activation...signal metrics and waveform itself were saved and transmitted to the home base. There is also a provision to download the entire recorded waveform
McDougall, I R
1995-10-01
Whole-body scintigraphy with radioiodine-131 is an important diagnostic test in the management of patients with differentiated thyroid cancer who have undergone surgical treatment. The scan can demonstrate the presence of residual thyroid or functioning metastases in lymph nodes or distant sites. However, there are a number of potential pitfalls in the interpretation of this scan that could lead to a false-positive diagnosis of cancer. The scintiscans are presented for five patients in whom uptake outside of the thyroid was not due to functioning metastases. Some of these abnormalities are physiologic, such as uptake of iodine in the gastrointestinal tract. A comprehensive list of false-positive results are tabulated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suzuki, Kenji; Yoshida, Hiroyuki; Naeppi, Janne
2006-10-15
One of the limitations of the current computer-aided detection (CAD) of polyps in CT colonography (CTC) is a relatively large number of false-positive (FP) detections. Rectal tubes (RTs) are one of the typical sources of FPs because a portion of a RT, especially a portion of a bulbous tip, often exhibits a cap-like shape that closely mimics the appearance of a small polyp. Radiologists can easily recognize and dismiss RT-induced FPs; thus, they may lose their confidence in CAD as an effective tool if the CAD scheme generates such ''obvious'' FPs due to RTs consistently. In addition, RT-induced FPs maymore » distract radiologists from less common true positives in the rectum. Therefore, removal RT-induced FPs as well as other types of FPs is desirable while maintaining a high sensitivity in the detection of polyps. We developed a three-dimensional (3D) massive-training artificial neural network (MTANN) for distinction between polyps and RTs in 3D CTC volumetric data. The 3D MTANN is a supervised volume-processing technique which is trained with input CTC volumes and the corresponding ''teaching'' volumes. The teaching volume for a polyp contains a 3D Gaussian distribution, and that for a RT contains zeros for enhancement of polyps and suppression of RTs, respectively. For distinction between polyps and nonpolyps including RTs, a 3D scoring method based on a 3D Gaussian weighting function is applied to the output of the trained 3D MTANN. Our database consisted of CTC examinations of 73 patients, scanned in both supine and prone positions (146 CTC data sets in total), with optical colonoscopy as a reference standard for the presence of polyps. Fifteen patients had 28 polyps, 15 of which were 5-9 mm and 13 were 10-25 mm in size. These CTC cases were subjected to our previously reported CAD scheme that included centerline-based segmentation of the colon, shape-based detection of polyps, and reduction of FPs by use of a Bayesian neural network based on geometric and texture features. Application of this CAD scheme yielded 96.4% (27/28) by-polyp sensitivity with 3.1 (224/73) FPs per patient, among which 20 FPs were caused by RTs. To eliminate the FPs due to RTs and possibly other normal structures, we trained a 3D MTANN with ten representative polyps and ten RTs, and applied the trained 3D MTANN to the above CAD true- and false-positive detections. In the output volumes of the 3D MTANN, polyps were represented by distributions of bright voxels, whereas RTs and other normal structures partly similar to RTs appeared as darker voxels, indicating the ability of the 3D MTANN to suppress RTs as well as other normal structures effectively. Application of the 3D MTANN to the CAD detections showed that the 3D MTANN eliminated all RT-induced 20 FPs, as well as 53 FPs due to other causes, without removal of any true positives. Overall, the 3D MTANN was able to reduce the FP rate of the CAD scheme from 3.1 to 2.1 FPs per patient (33% reduction), while the original by-polyp sensitivity of 96.4% was maintained.« less
Rapid automated method for screening of enteric pathogens from stool specimens.
Villasante, P A; Agulla, A; Merino, F J; Pérez, T; Ladrón de Guevara, C; Velasco, A C
1987-01-01
A total of 800 colonies suggestive of Salmonella, Shigella, or Yersinia species isolated on stool differential agar media were inoculated onto both conventional biochemical test media (triple sugar iron agar, urea agar, and phenylalanine agar) and Entero Pathogen Screen cards of the AutoMicrobic system (Vitek Systems, Inc., Hazelwood, Mo.). Based on the conventional tests, the AutoMicrobic system method yielded the following results: 587 true-negatives, 185 true-positives, 2 false-negatives, and 26 false-positives (sensitivity, 99%; specificity, 96%). Both true-positive and true-negative results were achieved considerably earlier than false results (P less than 0.001). The Entero Pathogen Screen card method is a fast, easy, and sensitive method for screening for Salmonella, Shigella, or Yersinia species. The impossibility of screening for oxidase-positive pathogens is a minor disadvantage of this method. PMID:3553230
The application of wavelet denoising in material discrimination system
NASA Astrophysics Data System (ADS)
Fu, Kenneth; Ranta, Dale; Guest, Clark; Das, Pankaj
2010-01-01
Recently, the need for cargo inspection imaging systems to provide a material discrimination function has become desirable. This is done by scanning the cargo container with x-rays at two different energy levels. The ratio of attenuations of the two energy scans can provide information on the composition of the material. However, with the statistical error from noise, the accuracy of such systems can be low. Because the moving source emits two energies of x-rays alternately, images from the two scans will not be identical. That means edges of objects in the two images are not perfectly aligned. Moreover, digitization creates blurry-edge artifacts. Different energy x-rays produce different edge spread functions. Those combined effects contribute to a source of false classification namely, the "edge effect." Other types of false classification are caused by noise, mainly Poisson noise associated with photons. The Poisson noise in xray images can be dealt with using either a Wiener filter or a wavelet shrinkage denoising approach. In this paper, we propose a method that uses the wavelet shrinkage denoising approach to enhance the performance of the material identification system. Test results show that this wavelet-based approach has improved performance in object detection and eliminating false positives due to the edge effects.
Risk management and precaution: insights on the cautious use of evidence.
Hrudey, Steve E; Leiss, William
2003-01-01
Risk management, done well, should be inherently precautionary. Adopting an appropriate degree of precaution with respect to feared health and environmental hazards is fundamental to risk management. The real problem is in deciding how precautionary to be in the face of inevitable uncertainties, demanding that we understand the equally inevitable false positives and false negatives from screening evidence. We consider a framework for detection and judgment of evidence of well-characterized hazards, using the concepts of sensitivity, specificity, positive predictive value, and negative predictive value that are well established for medical diagnosis. Our confidence in predicting the likelihood of a true danger inevitably will be poor for rare hazards because of the predominance of false positives; failing to detect a true danger is less likely because false negatives must be rarer than the danger itself. Because most controversial environmental hazards arise infrequently, this truth poses a dilemma for risk management. PMID:14527835
Emotion and false memory: How goal-irrelevance can be relevant for what people remember.
Van Damme, Ilse; Kaplan, Robin L; Levine, Linda J; Loftus, Elizabeth F
2017-02-01
Elaborating on misleading information concerning emotional events can lead people to form false memories. The present experiment compared participants' susceptibility to false memories when they elaborated on information associated with positive versus negative emotion and pregoal versus postgoal emotion. Pregoal emotion reflects appraisals that goal attainment or failure is anticipated but has not yet occurred (e.g., hope and fear). Postgoal emotion reflects appraisals that goal attainment or failure has already occurred (e.g., happiness and devastation). Participants watched a slideshow depicting an interaction between a couple and were asked to empathise with the protagonist's feelings of hope (positive pregoal), happiness (positive postgoal), fear (negative pregoal), or devastation (negative postgoal); in control conditions, no emotion was mentioned. Participants were then asked to reflect on details of the interaction that had occurred (true) or had not occurred (false), and that were relevant or irrelevant to the protagonist's goal. Irrespective of emotional valence, participants in the pregoal conditions were more susceptible to false memories concerning goal-irrelevant details than were participants in the other conditions. These findings support the view that pregoal emotions narrow attention to information relevant to goal pursuit, increasing susceptibility to false memories for irrelevant information.
Predicting the carcinogenicity of chemicals with alternative approaches: recent advances.
Benigni, Romualdo
2014-09-01
Alternative approaches to the rodent bioassay are necessary for early identification of problematic drugs and biocides during the development process, and are the only practicable tool for assessing environmental chemicals with no or adequate safety documentation. This review informs on: i) the traditional prescreening through genotoxicity testing; ii) an integrative approach that assesses DNA-reactivity and ability to disorganize tissues; iii) new applications of omics technologies (ToxCast/Tox21 project); iv) a pragmatic approach aimed at filling data gaps by intrapolating/extrapolating from similar chemicals (read-across, category formation). The review also approaches the issue of the concerns about false-positive and false-negative results that prevents a wider acceptance and use of alternatives. The review addresses strengths and limitations of various proposals, and concludes on the need of differential approaches to the issue of false negatives and false positives. False negatives can be eliminated or reduced below the variability of the animal assay with conservative quantitative structure-activity relationships or in vitro tests; false positives can be cleared with ad hoc mechanistically based follow-ups. This framework can permit a reduction of animal testing and a better protection of human health.
Analyzing false positives of four questions in the Force Concept Inventory
NASA Astrophysics Data System (ADS)
Yasuda, Jun-ichiro; Mae, Naohiro; Hull, Michael M.; Taniguchi, Masa-aki
2018-06-01
In this study, we analyze the systematic error from false positives of the Force Concept Inventory (FCI). We compare the systematic errors of question 6 (Q.6), Q.7, and Q.16, for which clearly erroneous reasoning has been found, with Q.5, for which clearly erroneous reasoning has not been found. We determine whether or not a correct response to a given FCI question is a false positive using subquestions. In addition to the 30 original questions, subquestions were introduced for Q.5, Q.6, Q.7, and Q.16. This modified version of the FCI was administered to 1145 university students in Japan from 2015 to 2017. In this paper, we discuss our finding that the systematic errors of Q.6, Q.7, and Q.16 are much larger than that of Q.5 for students with mid-level FCI scores. Furthermore, we find that, averaged over the data sample, the sum of the false positives from Q.5, Q.6, Q.7, and Q.16 is about 10% of the FCI score of a midlevel student.
Machine-learning-based real-bogus system for the HSC-SSP moving object detection pipeline
NASA Astrophysics Data System (ADS)
Lin, Hsing-Wen; Chen, Ying-Tung; Wang, Jen-Hung; Wang, Shiang-Yu; Yoshida, Fumi; Ip, Wing-Huen; Miyazaki, Satoshi; Terai, Tsuyoshi
2018-01-01
Machine-learning techniques are widely applied in many modern optical sky surveys, e.g., Pan-STARRS1, PTF/iPTF, and the Subaru/Hyper Suprime-Cam survey, to reduce human intervention in data verification. In this study, we have established a machine-learning-based real-bogus system to reject false detections in the Subaru/Hyper-Suprime-Cam Strategic Survey Program (HSC-SSP) source catalog. Therefore, the HSC-SSP moving object detection pipeline can operate more effectively due to the reduction of false positives. To train the real-bogus system, we use stationary sources as the real training set and "flagged" data as the bogus set. The training set contains 47 features, most of which are photometric measurements and shape moments generated from the HSC image reduction pipeline (hscPipe). Our system can reach a true positive rate (tpr) ˜96% with a false positive rate (fpr) ˜1% or tpr ˜99% at fpr ˜5%. Therefore, we conclude that stationary sources are decent real training samples, and using photometry measurements and shape moments can reject false positives effectively.
Kufa, Tendesayi; Lane, Tim; Manyuchi, Albert; Singh, Beverley; Isdahl, Zachary; Osmand, Thomas; Grasso, Mike; Struthers, Helen; McIntyre, James; Chipeta, Zawadi; Puren, Adrian
2017-01-01
Abstract We describe the accuracy of serial rapid HIV testing among men who have sex with men (MSM) in South Africa and discuss the implications for HIV testing and prevention. This was a cross-sectional survey conducted at five stand-alone facilities from five provinces. Demographic, behavioral, and clinical data were collected. Dried blood spots were obtained for HIV-related testing. Participants were offered rapid HIV testing using 2 rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using a third-generation enzyme immunoassay (EIA) and a fourth-generation EIA as confirmatory. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive, and false-negative rates were determined. Between August 2015 and July 2016, 2503 participants were enrolled. Of these, 2343 were tested by RDT on site with a further 2137 (91.2%) having definitive results on both RDT and EIA. Sensitivity, specificity, positive predictive value, negative predictive value, false-positive rates, and false-negative rates were 92.6% [95% confidence interval (95% CI) 89.6–94.8], 99.4% (95% CI 98.9–99.7), 97.4% (95% CI 95.2–98.6), 98.3% (95% CI 97.6–98.8), 0.6% (95% CI 0.3–1.1), and 7.4% (95% CI 5.2–10.4), respectively. False negatives were similar to true positives with respect to virological profiles. Overall accuracy of the RDT algorithm was high, but sensitivity was lower than expected. Post-HIV test counseling should include discussions of possible false-negative results and the need for retesting among HIV negatives. PMID:28700474
Muehlwald, S; Buchner, N; Kroh, L W
2018-03-23
Because of the high number of possible pesticide residues and their chemical complexity, it is necessary to develop methods which cover a broad range of pesticides. In this work, a qualitative multi-screening method for pesticides was developed by use of HPLC-ESI-Q-TOF. 110 pesticides were chosen for the creation of a personal compound database and library (PCDL). The MassHunter Qualitative Analysis software from Agilent Technologies was used to identify the analytes. The software parameter settings were optimised to produce a low number of false positive as well as false negative results. The method was validated for 78 selected pesticides. However, the validation criteria were not fulfilled for 45 analytes. Due to this result, investigations were started to elucidate reasons for the low detectability. It could be demonstrated that the three main causes of the signal suppression were the co-eluting matrix (matrix effect), the low sensitivity of the analyte in standard solution and the fragmentation of the analyte in the ion source (in-source collision-induced dissociation). In this paper different examples are discussed showing that the impact of these three causes is different for each analyte. For example, it is possible that an analyte with low signal intensity and an intense fragmentation in the ion source is detectable in a difficult matrix, whereas an analyte with a high sensitivity and a low fragmentation is not detectable in a simple matrix. Additionally, it could be shown that in-source fragments are a helpful tool for an unambiguous identification. Copyright © 2018 Elsevier B.V. All rights reserved.
Systematic Poisoning Attacks on and Defenses for Machine Learning in Healthcare.
Mozaffari-Kermani, Mehran; Sur-Kolay, Susmita; Raghunathan, Anand; Jha, Niraj K
2015-11-01
Machine learning is being used in a wide range of application domains to discover patterns in large datasets. Increasingly, the results of machine learning drive critical decisions in applications related to healthcare and biomedicine. Such health-related applications are often sensitive, and thus, any security breach would be catastrophic. Naturally, the integrity of the results computed by machine learning is of great importance. Recent research has shown that some machine-learning algorithms can be compromised by augmenting their training datasets with malicious data, leading to a new class of attacks called poisoning attacks. Hindrance of a diagnosis may have life-threatening consequences and could cause distrust. On the other hand, not only may a false diagnosis prompt users to distrust the machine-learning algorithm and even abandon the entire system but also such a false positive classification may cause patient distress. In this paper, we present a systematic, algorithm-independent approach for mounting poisoning attacks across a wide range of machine-learning algorithms and healthcare datasets. The proposed attack procedure generates input data, which, when added to the training set, can either cause the results of machine learning to have targeted errors (e.g., increase the likelihood of classification into a specific class), or simply introduce arbitrary errors (incorrect classification). These attacks may be applied to both fixed and evolving datasets. They can be applied even when only statistics of the training dataset are available or, in some cases, even without access to the training dataset, although at a lower efficacy. We establish the effectiveness of the proposed attacks using a suite of six machine-learning algorithms and five healthcare datasets. Finally, we present countermeasures against the proposed generic attacks that are based on tracking and detecting deviations in various accuracy metrics, and benchmark their effectiveness.
Laxative-free CT colonography.
Slater, A; Betts, M; D'Costa, H
2012-08-01
The aim of this study was to determine if the introduction of faecal tagging to CT colonography (CTC) made the examination easier to tolerate or reduced the number of false-positives. Our department changed bowel preparation for CT colonography from Picolax (Ferring Pharmaceuticals Ltd, London, UK) to Gastrografin (Bracco Diagnostics Inc, Princeton, NJ) only with a modified diet. Questionnaires were given to a subgroup of patients within these cohorts. The numbers of false-positives were compared between two cohorts before and after this change. false-positives were defined as lesions reported on CT that were not confirmed by subsequent endoscopic examination. Polyps were matched if they were in the same or adjacent segments, and were within 5 mm of the reported size. 412 patients were identified from the Picolax cohort, and 116 from the Gastrografin cohort. 62 patients in each group completed questionnaires. Gastrografin produced less diarrhoea; 34% had five or more bowel motions in the previous day and night, compared with 77% for Picolax (p<0.001), although more patients found drinking it unpleasant compared with Picolax (85% reported drinking Picolax as "easy" vs 61% for Gastrografin; p=0.002). Picolax produced more non-diagnostic examinations, although this difference was not statistically significant. There was not a significant reduction in the numbers of false-positives (2 out of 112 for Gastrografin group, 14 out of 389 for the Picolax group; p=0.54). Switching from Picolax to Gastrografin as a CTC preparation technique produced less diarrhoea, but did not reduce the number of false-positives.
When a Step Is Not a Step! Specificity Analysis of Five Physical Activity Monitors.
O'Connell, Sandra; ÓLaighin, Gearóid; Quinlan, Leo R
2017-01-01
Physical activity is an essential aspect of a healthy lifestyle for both physical and mental health states. As step count is one of the most utilized measures for quantifying physical activity it is important that activity-monitoring devices be both sensitive and specific in recording actual steps taken and disregard non-stepping body movements. The objective of this study was to assess the specificity of five activity monitors during a variety of prescribed non-stepping activities. Participants wore five activity monitors simultaneously for a variety of prescribed activities including deskwork, taking an elevator, taking a bus journey, automobile driving, washing and drying dishes; functional reaching task; indoor cycling; outdoor cycling; and indoor rowing. Each task was carried out for either a specific duration of time or over a specific distance. Activity monitors tested were the ActivPAL micro™, NL-2000™ pedometer, Withings Smart Activity Monitor Tracker (Pulse O2)™, Fitbit One™ and Jawbone UP™. Participants were video-recorded while carrying out the prescribed activities and the false positive step count registered on each activity monitor was obtained and compared to the video. All activity monitors registered a significant number of false positive steps per minute during one or more of the prescribed activities. The Withings™ activity performed best, registering a significant number of false positive steps per minute during the outdoor cycling activity only (P = 0.025). The Jawbone™ registered a significant number of false positive steps during the functional reaching task and while washing and drying dishes, which involved arm and hand movement (P < 0.01 for both). The ActivPAL™ registered a significant number of false positive steps during the cycling exercises (P < 0.001 for both). As a number of false positive steps were registered on the activity monitors during the non-stepping activities, the authors conclude that non-stepping physical activities can result in the false detection of steps. This can negatively affect the quantification of physical activity with regard to step count as an output. The Withings™ activity monitor performed best with regard to specificity during the activities of daily living tested.
Cais-Sokolińska, Dorota; Pikul, Jan; Wójtowski, Jacek; Danków, Romualda; Teichert, Joanna; Czyżak-Runowska, Grażyna; Bagnicka, Emilia
2015-04-01
The composition of bioactive components in dairy products depends on their content in raw milk and the processing conditions. The experimental material consisted of the milk of dairy goats supplemented with 120 g d(-1) per head of false flax cake. The aim of the study was to evaluate the quality of kefir produced from goat's milk with a higher content of bioactive components resulting from supplementation of the goats' diet with false flax cake. The administration of false flax cake to goats had a positive effect on the fatty acid profile of the raw milk, causing an increase in the proportion of polyunsaturated fatty acids (PUFA), including conjugated linoleic acid (CLA) and n-3 fatty acids. Their increased percentage was detected in the kefir after production as well as after storage. The processing value of the harvested milk did not differ from the qualitative characteristics of milk from goats of the control group. Increasing the proportion of bioactive components in goat's milk did not result in changes in the acidity, texture, colour, flavour, aroma or consistency of the kefir obtained. Milk and kefir obtained after the administration of false flax cake to goats contain bioactive components (PUFA including CLA, n-3 and monoenic trans fatty acids) in significant amounts. Kefir from experimental goat's milk did not differ in quality from kefir made from the milk of the control group. © 2014 Society of Chemical Industry.
Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Hwang, Jae Jin; Lee, Hyun Joo; Lee, AeRa; Jeong, Yeon Sang; Oh, Sooyeon; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho
2015-06-01
The (13)C-urea breath test ((13)C-UBT) is a noninvasive method for diagnosing Helicobacter pylori (H. pylori) infection. The aims of this study were to evaluate the diagnostic validity of the (13)C-UBT cutoff value and to identify influencing clinical factors responsible for aberrant results. (13)C-UBT (UBiTkit; Otsuka Pharmaceutical, cutoff value: 2.5‰) results in the range 2.0‰ to 10.0‰ after H. pylori eradication therapy were compared with the results of endoscopic biopsy results of the antrum and body. Factors considered to affect test results adversely were analyzed. Among patients with a positive (13)C-UBT result (2.5‰ to 10.0‰, n = 223) or a negative (13)C-UBT result (2.0‰ to < 2.5‰, n = 66) after H. pylori eradication, 73 patients (34.0%) were false positive, and one (1.5%) was false negative as determined by endoscopic biopsy. The sensitivity, specificity, false-positive rate, and false-negative rate for a cutoff value of 2.5‰ were 99.3%, 47.1%, 52.9%, and 0.7%, respectively, and positive and negative predictive values of the (13)C-UBT were 67.3% and 98.5%, respectively. Multivariate analysis showed that a history of two or more previous H. pylori eradication therapies (OR = 2.455, 95%CI = 1.299-4.641) and moderate to severe gastric intestinal metaplasia (OR = 3.359, 95%CI = 1.572-7.178) were associated with a false-positive (13)C-UBT result. The (13)C-UBT cutoff value currently used has poor specificity for confirming H. pylori status after eradication, and this lack of specificity is exacerbated in patients that have undergone multiple prior eradication therapies and in patients with moderate to severe gastric intestinal metaplasia. In addition, the citric-free (13)C-UBT would increase a false-positive (13)C-UBT result. © 2015 John Wiley & Sons Ltd.
New Constraints on the False Positive Rate for Short-Period Kepler Planet Candidates
NASA Astrophysics Data System (ADS)
Colón, Knicole D.; Morehead, Robert C.; Ford, Eric B.
2015-01-01
The Kepler space mission has discovered thousands of potential planets orbiting other stars, thereby setting the stage for in-depth studies of different populations of planets. We present new multi-wavelength transit photometry of small (Rp < 6 Earth radii), short-period (P < 6 days) Kepler planet candidates acquired with the Gran Telescopio Canarias. Multi-wavelength transit photometry allows us to search for wavelength-dependent transit depths and subsequently identify eclipsing binary false positives (which are especially prevalent at the shortest orbital periods). We combine these new observations of three candidates with previous results for five other candidates (Colón & Ford 2011 and Colón, Ford, & Morehead 2012) to provide new constraints on the false positive rate for small, close-in candidates. In our full sample, we identify four candidates as viable planets and four as eclipsing binary false positives. We therefore find a higher false positive rate for small, close-in candidates compared to the lower false positive rate of ~10% determined by other studies for the full sample of Kepler planet candidates (e.g. Fressin et al. 2013). We also discuss the dearth of known planets with periods less than ~2.5 days and radii between ~3 and 11 Earth radii (the so-called 'sub-Jovian desert'), since the majority of the candidates in our study are located in or around this 'desert.' The lack of planets with these orbital and physical properties is not expected to be due to observational bias, as short-period planets are generally easier to detect (especially if they are larger or more massive than Earth). We consider the implications of our results for the other ~20 Kepler planet candidates located in this desert. Characterizing these candidates will allow us to better understand the formation processes of this apparently rare class of planets.
Albayrak, Levent; Khanipov, Kamil; Pimenova, Maria; Golovko, George; Rojas, Mark; Pavlidis, Ioannis; Chumakov, Sergei; Aguilar, Gerardo; Chávez, Arturo; Widger, William R; Fofanov, Yuriy
2016-12-12
Low-abundance mutations in mitochondrial populations (mutations with minor allele frequency ≤ 1%), are associated with cancer, aging, and neurodegenerative disorders. While recent progress in high-throughput sequencing technology has significantly improved the heteroplasmy identification process, the ability of this technology to detect low-abundance mutations can be affected by the presence of similar sequences originating from nuclear DNA (nDNA). To determine to what extent nDNA can cause false positive low-abundance heteroplasmy calls, we have identified mitochondrial locations of all subsequences that are common or similar (one mismatch allowed) between nDNA and mitochondrial DNA (mtDNA). Performed analysis revealed up to a 25-fold variation in the lengths of longest common and longest similar (one mismatch allowed) subsequences across the mitochondrial genome. The size of the longest subsequences shared between nDNA and mtDNA in several regions of the mitochondrial genome were found to be as low as 11 bases, which not only allows using these regions to design new, very specific PCR primers, but also supports the hypothesis of the non-random introduction of mtDNA into the human nuclear DNA. Analysis of the mitochondrial locations of the subsequences shared between nDNA and mtDNA suggested that even very short (36 bases) single-end sequencing reads can be used to identify low-abundance variation in 20.4% of the mitochondrial genome. For longer (76 and 150 bases) reads, the proportion of the mitochondrial genome where nDNA presence will not interfere found to be 44.5 and 67.9%, when low-abundance mutations at 100% of locations can be identified using 417 bases long single reads. This observation suggests that the analysis of low-abundance variations in mitochondria population can be extended to a variety of large data collections such as NCBI Sequence Read Archive, European Nucleotide Archive, The Cancer Genome Atlas, and International Cancer Genome Consortium.
Accuracy evaluation of a new real-time continuous glucose monitoring algorithm in hypoglycemia.
Mahmoudi, Zeinab; Jensen, Morten Hasselstrøm; Dencker Johansen, Mette; Christensen, Toke Folke; Tarnow, Lise; Christiansen, Jens Sandahl; Hejlesen, Ole
2014-10-01
The purpose of this study was to evaluate the performance of a new continuous glucose monitoring (CGM) calibration algorithm and to compare it with the Guardian(®) REAL-Time (RT) (Medtronic Diabetes, Northridge, CA) calibration algorithm in hypoglycemia. CGM data were obtained from 10 type 1 diabetes patients undergoing insulin-induced hypoglycemia. Data were obtained in two separate sessions using the Guardian RT CGM device. Data from the same CGM sensor were calibrated by two different algorithms: the Guardian RT algorithm and a new calibration algorithm. The accuracy of the two algorithms was compared using four performance metrics. The median (mean) of absolute relative deviation in the whole range of plasma glucose was 20.2% (32.1%) for the Guardian RT calibration and 17.4% (25.9%) for the new calibration algorithm. The mean (SD) sample-based sensitivity for the hypoglycemic threshold of 70 mg/dL was 31% (33%) for the Guardian RT algorithm and 70% (33%) for the new algorithm. The mean (SD) sample-based specificity at the same hypoglycemic threshold was 95% (8%) for the Guardian RT algorithm and 90% (16%) for the new calibration algorithm. The sensitivity of the event-based hypoglycemia detection for the hypoglycemic threshold of 70 mg/dL was 61% for the Guardian RT calibration and 89% for the new calibration algorithm. Application of the new calibration caused one false-positive instance for the event-based hypoglycemia detection, whereas the Guardian RT caused no false-positive instances. The overestimation of plasma glucose by CGM was corrected from 33.2 mg/dL in the Guardian RT algorithm to 21.9 mg/dL in the new calibration algorithm. The results suggest that the new algorithm may reduce the inaccuracy of Guardian RT CGM system within the hypoglycemic range; however, data from a larger number of patients are required to compare the clinical reliability of the two algorithms.
Parametric vs. non-parametric statistics of low resolution electromagnetic tomography (LORETA).
Thatcher, R W; North, D; Biver, C
2005-01-01
This study compared the relative statistical sensitivity of non-parametric and parametric statistics of 3-dimensional current sources as estimated by the EEG inverse solution Low Resolution Electromagnetic Tomography (LORETA). One would expect approximately 5% false positives (classification of a normal as abnormal) at the P < .025 level of probability (two tailed test) and approximately 1% false positives at the P < .005 level. EEG digital samples (2 second intervals sampled 128 Hz, 1 to 2 minutes eyes closed) from 43 normal adult subjects were imported into the Key Institute's LORETA program. We then used the Key Institute's cross-spectrum and the Key Institute's LORETA output files (*.lor) as the 2,394 gray matter pixel representation of 3-dimensional currents at different frequencies. The mean and standard deviation *.lor files were computed for each of the 2,394 gray matter pixels for each of the 43 subjects. Tests of Gaussianity and different transforms were computed in order to best approximate a normal distribution for each frequency and gray matter pixel. The relative sensitivity of parametric vs. non-parametric statistics were compared using a "leave-one-out" cross validation method in which individual normal subjects were withdrawn and then statistically classified as being either normal or abnormal based on the remaining subjects. Log10 transforms approximated Gaussian distribution in the range of 95% to 99% accuracy. Parametric Z score tests at P < .05 cross-validation demonstrated an average misclassification rate of approximately 4.25%, and range over the 2,394 gray matter pixels was 27.66% to 0.11%. At P < .01 parametric Z score cross-validation false positives were 0.26% and ranged from 6.65% to 0% false positives. The non-parametric Key Institute's t-max statistic at P < .05 had an average misclassification error rate of 7.64% and ranged from 43.37% to 0.04% false positives. The nonparametric t-max at P < .01 had an average misclassification rate of 6.67% and ranged from 41.34% to 0% false positives of the 2,394 gray matter pixels for any cross-validated normal subject. In conclusion, adequate approximation to Gaussian distribution and high cross-validation can be achieved by the Key Institute's LORETA programs by using a log10 transform and parametric statistics, and parametric normative comparisons had lower false positive rates than the non-parametric tests.
The reproducibility of research and the misinterpretation of p-values
2017-01-01
We wish to answer this question: If you observe a ‘significant’ p-value after doing a single unbiased experiment, what is the probability that your result is a false positive? The weak evidence provided by p-values between 0.01 and 0.05 is explored by exact calculations of false positive risks. When you observe p = 0.05, the odds in favour of there being a real effect (given by the likelihood ratio) are about 3 : 1. This is far weaker evidence than the odds of 19 to 1 that might, wrongly, be inferred from the p-value. And if you want to limit the false positive risk to 5%, you would have to assume that you were 87% sure that there was a real effect before the experiment was done. If you observe p = 0.001 in a well-powered experiment, it gives a likelihood ratio of almost 100 : 1 odds on there being a real effect. That would usually be regarded as conclusive. But the false positive risk would still be 8% if the prior probability of a real effect were only 0.1. And, in this case, if you wanted to achieve a false positive risk of 5% you would need to observe p = 0.00045. It is recommended that the terms ‘significant’ and ‘non-significant’ should never be used. Rather, p-values should be supplemented by specifying the prior probability that would be needed to produce a specified (e.g. 5%) false positive risk. It may also be helpful to specify the minimum false positive risk associated with the observed p-value. Despite decades of warnings, many areas of science still insist on labelling a result of p < 0.05 as ‘statistically significant’. This practice must contribute to the lack of reproducibility in some areas of science. This is before you get to the many other well-known problems, like multiple comparisons, lack of randomization and p-hacking. Precise inductive inference is impossible and replication is the only way to be sure. Science is endangered by statistical misunderstanding, and by senior people who impose perverse incentives on scientists. PMID:29308247
Veyres, Nicolas; Hamadjida, Adjia; Huot, Philippe
2018-05-01
The 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-lesioned primate is the gold-standard animal model of Parkinson disease (PD) and has been used to assess the effectiveness of experimental drugs on dyskinesia, parkinsonism, and psychosis. Three species have been used in most studies-the macaque, marmoset, and squirrel monkey-the last much less so than the first two species; however, the predictive value of each species at forecasting clinical efficacy, or lack thereof, is poorly documented. Here, we have reviewed all the published literature detailing pharmacologic studies that assessed the effects of experimental drugs on dyskinesia, parkinsonism, and psychosis in each of these species and have calculated their predictive value of success and failure at the clinical level. We found that, for dyskinesia, the macaque has a positive predictive value of 87.5% and a false-positive rate of 38.1%, whereas the marmoset has a positive predictive value of 76.9% and a false-positive rate of 15.6%. For parkinsonism, the macaque has a positive predictive value of 68.2% and a false-positive rate of 44.4%, whereas the marmoset has a positive predictive value of 86.9% and a false-positive rate of 41.7%. No drug that alleviates psychosis in the clinic has shown efficacy at doing so in the macaque, whereas the marmoset has 100% positive predictive value. The small number of studies conducted in the squirrel monkey precluded us from calculating its predictive efficacy. We hope our results will help in the design of pharmacologic experiments and will facilitate the drug discovery and development process in PD. Copyright © 2018 by The American Society for Pharmacology and Experimental Therapeutics.
Frederick, R I
2000-01-01
Mixed group validation (MGV) is offered as an alternative to criterion group validation (CGV) to estimate the true positive and false positive rates of tests and other diagnostic signs. CGV requires perfect confidence about each research participant's status with respect to the presence or absence of pathology. MGV determines diagnostic efficiencies based on group data; knowing an individual's status with respect to pathology is not required. MGV can use relatively weak indicators to validate better diagnostic signs, whereas CGV requires perfect diagnostic signs to avoid error in computing true positive and false positive rates. The process of MGV is explained, and a computer simulation demonstrates the soundness of the procedure. MGV of the Rey 15-Item Memory Test (Rey, 1958) for 723 pre-trial criminal defendants resulted in higher estimates of true positive rates and lower estimates of false positive rates as compared with prior research conducted with CGV. The author demonstrates how MGV addresses all the criticisms Rogers (1997b) outlined for differential prevalence designs in malingering detection research. Copyright 2000 John Wiley & Sons, Ltd.
2012-01-01
Background We previously investigated the current status of breast cytology cancer screening at seven institutes in our area of southern Fukuoka Prefecture, and found some differences in diagnostic accuracy among the institutions. In the present study, we evaluated the cases involved and noted possible reasons for their original cytological classification as inadequate, indeterminate, false-negative and false-positive according to histological type. Methods We evaluated the histological findings in 5693 individuals who underwent cytological examination for breast cancer (including inadequate, indeterminate, false-negative and false-positive cases), to determine the most common histological types and/or features in these settings and the usefulness/limitations of cytological examination for the diagnosis of breast cancer. Results Among 1152 cytologically inadequate cases, histology revealed that 75/173 (43.6%) cases were benign, including mastopathy (fibrocystic disease) in 38.6%, fibroadenoma in 24.0% and papilloma in 5.3%. Ninety-five of 173 (54.9%) cases were histologically malignant, with scirrhous growing type, invasive ductal carcinoma (SIDC) being significantly more frequent (49.5%) than papillotubular growing type (Papi-tub) (P < 0.0001), solid-tubular growing type (P = 0.0001) and ductal carcinoma in situ (DCIS) (P = 0.0001). Among 458 indeterminate cases, 54/139 (38.8%) were histologically benign (mastopathy, 30.0%; fibroadenoma, 27.8%; papilloma, 26.0%) and 73/139 (52.5%) were malignant, with SIDC being the most frequent malignant tumor (37.0%). Among 52 false-negative cases, SIDC was significantly more frequent (42.3%) than DCIS (P = 0.0049) and Papi-tub (P = 0.001). There were three false-positive cases, with one each of fibroadenoma, epidermal cyst and papilloma. Conclusions The inadequate, indeterminate, false-negative and false-positive cases showed similar histological types, notably SIDC for malignant tumors, and mastopathy, fibroadenoma and papilloma for benign cases. We need to pay particular attention to the collection and assessment of aspirates for these histological types of breast disease. In particular, several inadequate, indeterminate and false-negative cases with samples collected by aspiration were diagnosed as SIDC. These findings should encourage the use of needle biopsy rather than aspiration when this histological type is identified on imaging. Namely, good communication between clinicians and pathological staff, and triple assessment (i.e., clinical, pathological and radiological assessment), are important for accurate diagnosis of aspiration samples. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/7349809170055423 PMID:22607447
Griffey, Richard T; Trent, Caleb J; Bavolek, Rebecca A; Keeperman, Jacob B; Sampson, Christopher; Poirier, Robert F
2013-01-01
Failure to detect pregnancy in the emergency department (ED) can have important consequences. Urine human chorionic gonadotropin (uhCG) point-of-care (POC) assays are valued for rapidly detecting early pregnancy with high sensitivity. However, under certain conditions, POC uhCG tests can fail to detect pregnancy. In investigating a series of late first-trimester false-negative pregnancy tests in our ED, a novel and distinct causative phenomenon was recently elucidated in our institution. We discuss uhCG POC tests, review our false-negative rate, and describe mechanisms for false negatives and potential remedies. The false-negative POC uhCG rate is very low, but in the setting of a large volume of tests, the numbers are worth consideration. In positive uhCG POC tests, free and fixed antibodies bind hCG to form a "sandwich"; hCG is present in several variant forms that change in their concentrations at different stages of pregnancy. When in excess, intact hCG can saturate the antibodies, preventing sandwich formation (hook effect phenomenon). Some assays may include an antibody that does not recognize certain variants present in later stages of pregnancy. When this variant is in excess, it can bind one antibody avidly and the other not at all, resulting in a false-negative test (hook-like phenomenon). In both situations, dilution is key to an accurate test. Manufacturers should consider that uhCG tests are routinely used at many stages of pregnancy. Characterizing uhCG variants recognized by their tests and eliminating lot-to-lot variability may help improve uhCG test performance. Clinicians need to be aware of and familiarize themselves with the limitations of the specific type of uhCG POC tests used in their practice, recognizing that under certain circumstances, false-negative tests can occur. Copyright © 2013 Elsevier Inc. All rights reserved.
Woyessa, Adugna; Deressa, Wakgari; Ali, Ahmed; Lindtjørn, Bernt
2013-06-27
Malaria is a major public health problem in Ethiopia. Plasmodium falciparum and Plasmodium vivax co-exist and malaria rapid diagnostic test (RDTs) is vital in rendering parasite-confirmed treatment especially in areas where microscopy from 2008 to 2010 is not available. CareStartTM Malaria Pf/Pv combo test was evaluated compared to microscopy in Butajira area, south-central Ethiopia. This RDT detects histidine-rich protein-2 (HRP2) found in P. falciparum, and Plasmodium enzyme lactate dehydrogenase (pLDH) for diagnosis of P. vivax. The standard for the reporting of diagnostic accuracy studies was complied. Among 2,394 participants enrolled, 10.9% (n=87) were Plasmodium infected (household survey) and 24.5% (n=392) health facility-based using microscopy. In the household surveys, the highest positivity was caused by P. vivax (83.9%, n=73), P. falciparum (15.0%, n=13), and the rest due to mixed infections of both (1.1%, n=1). In health facility, P. vivax caused 78.6% (n=308), P. falciparum caused 20.4% (n=80), and the rest caused by mixed infections 1.0% (n=4). RDT missed 9.1% (n=8) in household and 4.3% (n=17) in health facility-based surveys among Plasmodium positive confirmed by microscopy while 3.3% (n=24) in household and 17.2% (n=208) in health facility-based surveys were detected false positive. RDT showed agreement with microscopy in detecting 79 positives in household surveys (n=796) and 375 positives in health centre survey (n=1,598).RDT performance varied in both survey settings, lowest PPV (64.3%) for Plasmodium and P. falciparum (77.2%) in health centres; and Plasmodium (76.7%) and P. falciparum (87.5%) in household surveys. NPV was low in P. vivax in health centres (77.2%) and household (87.5%) surveys. Seasonally varying RDT precision of as low as 14.3% PPV (Dec. 2009), and 38.5% NPV (Nov. 2008) in health centre surveys; and 40-63.6% PPV was observed in household surveys. But the influence of age and parasite density on RDT performance was not ascertained. Establishing quality control of malaria RDT in the health system in areas with low endemic and where P. falciparum and P. vivax co-exist is recommendable. CareStartTM RDT might be employed for epidemiological studies that require interpreting the results cautiously. Future RDT field evaluation against microscopy should be PCR corrected.
Ishihara, Shinsuke; Labuta, Jan; Nakanishi, Takashi; Tanaka, Takeshi; Kataura, Hiromichi
2017-10-27
We report amperometric detection of formaldehyde (HCHO) using hydroxylamine hydrochloride and single-walled carbon nanotubes (SWCNTs). Hydroxylamine hydrochloride reacts with HCHO to emit HCl vapor, which injects a hole carrier into semiconducting SWCNTs. The increase of conductivity in SWCNTs is easily monitored using an ohmmeter. The debundling of SWCNTs with a metallo-supramolecular polymer (MSP) increased the active surface area in the SWCNTs network, leading to excellent sensitivity to HCHO with a limit of detection (LoD) of 0.016 ppm. The response of sensor is reversible, and the sensor is reusable. The selectivity to HCHO is 10 5 -10 6 times higher than interferences with other volatiles such as water, methanol, and toluene. Moreover, false-positive responses caused by a significant variation of humidity and/or temperature are successfully discriminated from true-positive responses by using two sensors, one with and the other without hydroxylamine hydrochloride, in a referenced system.
[Recurrent miscarriage turns out to be lung cancer].
Ebisch, Inge M W; Limonard, Gijs J M; Vreuls, Willem; Sporken, Jan M J
2013-01-01
If a positive pregnancy test is followed by profuse vaginal bleeding, the diagnosis of miscarriage can generally be made. Sometimes, however, elevated hCG levels may be associated with a phantom pregnancy, which may be a paraneoplastic symptom. A 27-year-old woman was referred for a diagnosis after having experienced 3 consecutive miscarriages. The diagnostic workup could not identify an underlying cause. After 3 more biochemical miscarriages, the original diagnosis was called into question and extensive testing for ectopic hCG production was performed. It appeared that the false pregnancies were paraneoplastic symptoms of an hCG-producing non-small cell lung cancer. After a lobectomy, the hCG levels returned to normal and a spontaneous pregnancy and uncomplicated delivery followed. Phantom pregnancy as a paraneoplastic symptom is extremely rare, but should be considered in patients presenting with recurrent, non-objectifiable miscarriages. Careful documentation of the menstrual cycle is necessary for early detection of the condition. The fact is that vaginal bleeding after a positive pregnancy test can still be a normal menstruation.
Sundar, Kaushik; Venkatasubramanian, Shankar; Shanmugam, Sundar; Arthur, Preetam; Subbaraya, Ramakrishnan; Hazeena, Philo
2017-10-15
Acute flaccid paralysis is a neuromuscular emergency characterized by rapidly worsening weakness that evolves quickly to cause diaphragmatic failure. The challenge for the treating physician is to stabilize the patient, generate the differential diagnosis and determine the management; all in quick time. Neurotoxic snake bites have inadequate signs of inflammation and are easily missed. Myasthenic crisis, on the other hand, could be the first sign of myasthenia gravis in up to 20% of patients. Both present with acute respiratory failure and inadequate history. Two of our patients presented with similar clinical picture, and received polyvalent anti-snake venom obtained from hyperimmunised horses (Equus caballus). Both tested positive for anti-acetyl choline receptor antibody. After recovery, both patients narrated a history suggestive of neurotoxic envenomation. We later discovered that patients, who are exposed to polyvalent anti-snake venom (Equus caballus) prior to radioimmunoassay, demonstrate high titers of Anti-AChR Ab in their serum erroneously. Copyright © 2017 Elsevier B.V. All rights reserved.
Larsen, C P; Ezligini, F; Hermansen, N O; Kjeldsen-Kragh, J
2005-02-01
Approximately 1 in every 2000 units of platelets is contaminated with bacteria. The BacT/ALERT automated blood culture system can be used to screen platelet concentrates (PCs) for bacterial contamination. Data were collected from May 1998 until May 2004. The number of PCs tested during this period was 36 896, most of which were produced from pools of four buffy-coats. On the day following blood collection or platelet apheresis, a 5-10 ml sample of the PC was aseptically transferred to a BacT/ALERT culture bottle for detection of aerobic bacteria. The sample was monitored for bacterial growth during the entire storage period of the PC (6.5 days). When a positive signal was generated, the culture bottle, the PC and the erythrocyte concentrates were tested for bacterial growth. In order to determine the frequency of false-negative BacT/ALERT signals, 1061 outdated PCs were tested during the period from May 2002 to May 2004. Eighty-eight positive signals were detected by the BacT/ALERT system, of which 12 were interpreted as truly positive. Fourteen signals were interpreted as truly false positive. Thirty-three signals were interpreted to be probably false positive. Two of 1061 outdated units tested positive, and Bacillus spp. and Staphylococcus epidermidis, respectively, were isolated from these PCs. Between 0.03% and 0.12% of the PCs were contaminated with bacteria. BacT/ALERT is an efficient tool for monitoring PCs for bacterial contamination; however, it is important to realize that false-negative results may occur.
Multi-Stage System for Automatic Target Recognition
NASA Technical Reports Server (NTRS)
Chao, Tien-Hsin; Lu, Thomas T.; Ye, David; Edens, Weston; Johnson, Oliver
2010-01-01
A multi-stage automated target recognition (ATR) system has been designed to perform computer vision tasks with adequate proficiency in mimicking human vision. The system is able to detect, identify, and track targets of interest. Potential regions of interest (ROIs) are first identified by the detection stage using an Optimum Trade-off Maximum Average Correlation Height (OT-MACH) filter combined with a wavelet transform. False positives are then eliminated by the verification stage using feature extraction methods in conjunction with neural networks. Feature extraction transforms the ROIs using filtering and binning algorithms to create feature vectors. A feedforward back-propagation neural network (NN) is then trained to classify each feature vector and to remove false positives. The system parameter optimizations process has been developed to adapt to various targets and datasets. The objective was to design an efficient computer vision system that can learn to detect multiple targets in large images with unknown backgrounds. Because the target size is small relative to the image size in this problem, there are many regions of the image that could potentially contain the target. A cursory analysis of every region can be computationally efficient, but may yield too many false positives. On the other hand, a detailed analysis of every region can yield better results, but may be computationally inefficient. The multi-stage ATR system was designed to achieve an optimal balance between accuracy and computational efficiency by incorporating both models. The detection stage first identifies potential ROIs where the target may be present by performing a fast Fourier domain OT-MACH filter-based correlation. Because threshold for this stage is chosen with the goal of detecting all true positives, a number of false positives are also detected as ROIs. The verification stage then transforms the regions of interest into feature space, and eliminates false positives using an artificial neural network classifier. The multi-stage system allows tuning the detection sensitivity and the identification specificity individually in each stage. It is easier to achieve optimized ATR operation based on its specific goal. The test results show that the system was successful in substantially reducing the false positive rate when tested on a sonar and video image datasets.
Krüger, Carsten; Malleyeck, Isaack
2010-05-01
With 700,000 to 1.5 million new cases annually, congenital syphilis remains a major infectious cause of morbidity and mortality in neonates, infants and children in resource-poor countries. We therefore analyzed the extent of congenital syphilis in the pediatric patient population at our rural hospital in Tanzania. For this retrospective analysis, from January 1, 1998 to August 31, 2000, all cases of congenital syphilis were collected from the medical records of the neonatal and pediatric department at Haydom Lutheran Hospital in rural northern Tanzania. Age, sex, weight, clinical signs and symptoms, venereal disease research laboratory (VDRL) results of mother and/or child, hemoglobin concentration, treatment, and outcome were recorded and analyzed. Fourteen neonates and infants were included. The earlier the diagnosis, the more it rested on maternal data because the presentation of neonatal congenital syphilis resembled neonatal sepsis. Syphilitic skin lesions were only seen in the post-neonatal age group. VDRL results were positive in 11 of the 14 mothers, and in 4 of the infants. Anemia was common in older infants. No patient showed signs of central nervous system involvement. Two patients died, and the remaining were cured after standard treatment with procaine penicillin. Highlighting the variable picture of congenital syphilis, this report demonstrates how difficult it is to make a correct diagnosis by solely history and clinical presentation in a resource-poor setting. Hence false-positive and false-negative diagnoses are common, and clinicians have to maintain a high index of suspicion in diagnosing congenital syphilis. Therefore, an important approach to control and finally eliminate congenital syphilis as a major public health problem will be universal on-site syphilis screening of all pregnant women at their first antenatal visit and immediate treatment for those who test positive.
Owusu, Ewurama D A; Djonor, Samson K; Brown, Charles A; Grobusch, Martin P; Mens, Petra F
2018-02-23
Plasmodium falciparum, the most dominant species in sub-Saharan Africa, causes the most severe clinical malaria manifestations. In resource-limited Ghana, where malaria and HIV geographically overlap, histidine-rich protein 2 (HRP2)-based rapid diagnostic test (RDT) is a faster, easier and cheaper alternative to clinical gold standard light microscopy. However, mutations in parasite hrp2 gene may result in missed infections, which have severe implications for malaria control. The performance of a common HRP2-based RDT and expert light microscopy in HIV-positive and HIV-negative children under 5 years old was compared with PCR as laboratory gold standard. Finger-prick capillary blood was tested with First Response ® Malaria Ag P. falciparum (HRP2). Giemsa-stained thick and thin blood films were examined with ≥ 200 high power fields and parasites counted per 200 white blood cells. Nested PCR species identification of P. falciparum was performed and resolved on agarose gel. False negatives from RDT were further tested for deleted pfhrp2/3 and flanking genes, using PCR. The study was performed in two anti-retroviral therapy clinics in Accra and Atibie. Out of 401 participants enrolled, 150 were HIV positive and 251 HIV negative. Malaria was more prevalent in children without HIV. Microscopy had a higher sensitivity [100% (99-100)] than RDT [83% (53.5-100)]. Parasites with pfhrp2/3 deletions contributed to missed infections from RDT false negatives. Circulation of malaria parasites with pfrhp2/3 deletions in this population played a role in missed infections with RDT. This ought to be addressed if further strides in malaria control are to be made.
Recombinant allergen-based IgE testing to distinguish bee and wasp allergy.
Mittermann, Irene; Zidarn, Mihaela; Silar, Mira; Markovic-Housley, Zora; Aberer, Werner; Korosec, Peter; Kosnik, Mitja; Valenta, Rudolf
2010-06-01
The identification of the disease-causing insect in venom allergy is often difficult. To establish recombinant allergen-based IgE tests to diagnose bee and yellow jacket wasp allergy. Sera from patients with bee and/or wasp allergy (n = 43) and patients with pollen allergy with false-positive IgE serology to venom extracts were tested for IgE reactivity in allergen extract-based tests or with purified allergens, including nonglycosylated Escherichia coli-expressed recombinant (r) Api m 1, rApi m 2, rVes v 5, and insect cell-expressed, glycosylated rApi m 2 as well as 2 natural plant glycoproteins (Phl p 4, bromelain). The patients with venom allergy could be diagnosed with a combination of E coli-expressed rApi m 1, rApi m 2, and rVes v 5 whereas patients with pollen allergy remained negative. For a group of 29 patients for whom the sensitizing venom could not be identified with natural allergen extracts, testing with nonglycosylated allergens allowed identification of the sensitizing venom. Recombinant nonglycosylated allergens also allowed definition of the sensitizing venom for those 14 patients who had reacted either with bee or wasp venom extracts. By IgE inhibition studies, it is shown that glycosylated Api m 2 contains carbohydrate epitopes that cross-react with natural Api m 1, Ves v 2, natural Phl p 4, and bromelain, thus identifying cross-reactive structures responsible for serologic false-positive test results or double-positivity to bee and wasp extracts. Nonglycosylated recombinant bee and wasp venom allergens allow the identification of patients with bee and wasp allergy and should facilitate accurate prescription of venom immunotherapy. Copyright (c) 2010 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.
The semantics of emotion in false memory.
Brainerd, C J; Bookbinder, S H
2018-03-26
The emotional valence of target information has been a centerpiece of recent false memory research, but in most experiments, it has been confounded with emotional arousal. We sought to clarify the results of such research by identifying a shared mathematical relation between valence and arousal ratings in commonly administered normed materials. That relation was then used to (a) decide whether arousal as well as valence influences false memory when they are confounded and to (b) determine whether semantic properties that are known to affect false memory covary with valence and arousal ratings. In Study 1, we identified a quadratic relation between valence and arousal ratings of words and pictures that has 2 key properties: Arousal increases more rapidly as function of negative valence than positive valence, and hence, a given level of negative valence is more arousing than the same level of positive valence. This quadratic function predicts that if arousal as well as valence affects false memory when they are confounded, false memory data must have certain fine-grained properties. In Study 2, those properties were absent from norming data for the Cornell-Cortland Emotional Word Lists, indicating that valence but not arousal affects false memory in those norms. In Study 3, we tested fuzzy-trace theory's explanation of that pattern: that valence ratings are positively related to semantic properties that are known to increase false memory, but arousal ratings are not. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Kim, Mi Young; Choi, Nami; Yang, Jung-Hyun; Yoo, Young Bum; Park, Kyoung Sik
2015-10-01
Shear-wave elastography (SWE) has the potential to improve diagnostic performance of conventional ultrasound (US) in differentiating benign from malignant breast masses. To investigate false positive or negative results of SWE in differentiating benign from malignant breast masses and to analyze clinical and imaging characteristics of the masses with false SWE findings. From May to October 2013, 166 breast lesions of 164 consecutive women (mean age, 45.3 ± 10.1 years) who had been scheduled for biopsy were included. Conventional US and SWE were performed in all women before biopsy. Clinical, ultrasonographic morphologic features and SWE parameters (pattern classification and standard deviation [SD]) were recorded and compared with the histopathology results. Patient and lesion factors in the "true" and "false" groups were compared. Of the 166 masses, 118 (71.1%) were benign and 48 (28.9%) were malignant. False SWE features were more frequently observed in benign masses. False positive rates of benign masses and false negative rates of malignancy were 53% and 8.2%, respectively, using SWE pattern analysis and were 22.4% and 10.3%, respectively, using SD values. A lesion boundary of the masses on US (P = 0.039) and younger patient age (P = 0.047) were significantly associated with false SWE findings. These clinical and ultrasonographic features need to be carefully evaluated in performance and interpretation of SWE examinations. © The Foundation Acta Radiologica 2014.
False recognition of facial expressions of emotion: causes and implications.
Fernández-Dols, José-Miguel; Carrera, Pilar; Barchard, Kimberly A; Gacitua, Marta
2008-08-01
This article examines the importance of semantic processes in the recognition of emotional expressions, through a series of three studies on false recognition. The first study found a high frequency of false recognition of prototypical expressions of emotion when participants viewed slides and video clips of nonprototypical fearful and happy expressions. The second study tested whether semantic processes caused false recognition. The authors found that participants made significantly higher error rates when asked to detect expressions that corresponded to semantic labels than when asked to detect visual stimuli. Finally, given that previous research reported that false memories are less prevalent in younger children, the third study tested whether false recognition of prototypical expressions increased with age. The authors found that 67% of eight- to nine-year-old children reported nonpresent prototypical expressions of fear in a fearful context, but only 40% of 6- to 7-year-old children did so. Taken together, these three studies demonstrate the importance of semantic processes in the detection and categorization of prototypical emotional expressions.
Detecting False Positives in Multielement Designs: Implications for Brief Assessments
ERIC Educational Resources Information Center
Bartlett, Sara M.; Rapp, John T.; Henrickson, Marissa L.
2011-01-01
The authors assessed the extent to which multielement designs produced false positives using continuous duration recording (CDR) and interval recording with 10-s and 1-min interval sizes. Specifically, they created 6,000 graphs with multielement designs that varied in the number of data paths, and the number of data points per data path, using a…
IS HCI THAT IS USED AS A PRESERVATIVE CREATING FALSE POSITIVES FOR TBA IN GROUND WATER
Will hydrochloric acid produce false positives for TBA? Yes, if you heat the sample to get a lower detection limit for TBA. Conventional purge and trap methods at ambient temperature have a reporting limit for TBA between 50 and 100 g/liter. This is higher than the provisiona...
ERIC Educational Resources Information Center
Shear, Benjamin R.; Zumbo, Bruno D.
2013-01-01
Type I error rates in multiple regression, and hence the chance for false positive research findings, can be drastically inflated when multiple regression models are used to analyze data that contain random measurement error. This article shows the potential for inflated Type I error rates in commonly encountered scenarios and provides new…
Are False-Positive Rates Leading to an Overestimation of Noise-Induced Hearing Loss?
ERIC Educational Resources Information Center
Schlauch, Robert S.; Carney, Edward
2011-01-01
Purpose: To estimate false-positive rates for rules proposed to identify early noise-induced hearing loss (NIHL) using the presence of notches in audiograms. Method: Audiograms collected from school-age children in a national survey of health and nutrition (the Third National Health and Nutrition Examination Survey [NHANES III]; National Center…
Yamatsuji, Tomoki; Ishida, Naomasa; Takaoka, Munenori; Hayashi, Jiro; Yoshida, Kazuhiro; Shigemitsu, Kaori; Urakami, Atsushi; Haisa, Minoru; Naomoto, Yoshio
2017-01-01
Of 129 esophagectomies at our institute from June 2010 to March 2015, we experienced three preoperative positron emission tomography-computed tomographic (PET/CT) false positives. Bone metastasis was originally suspected in 2 cases, but they were later found to be bone metastasis negative after a preoperative bone biopsy and clinical course observation. The other cases suspected of mediastinal lymph node metastasis were diagnosed as inflammatory lymphadenopathy by a pathological examination of the removed lymph nodes. Conducting a PET/CT is useful when diagnosing esophageal cancer metastasis, but we need to be aware of the possibility of false positives. Therapeutic decisions should be made based on appropriate and accurate diagnoses, with pathological diagnosis actively introduced if necessary. PMID:28469502