Sample records for falsely positive determinations

  1. Methods for threshold determination in multiplexed assays

    DOEpatents

    Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J

    2014-06-24

    Methods for determination of threshold values of signatures comprised in an assay are described. Each signature enables detection of a target. The methods determine a probability density function of negative samples and a corresponding false positive rate curve. A false positive criterion is established and a threshold for that signature is determined as a point at which the false positive rate curve intersects the false positive criterion. A method for quantitative analysis and interpretation of assay results together with a method for determination of a desired limit of detection of a signature in an assay are also described.

  2. Commercial radioimmunoassay for beta subunit of human chorionic gonadotropin: falsely positive determinations due to elevated serum luteinizing hormone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowler, J.E. Jr.; Platoff, G.E.; Kubrock, C.A.

    1982-01-01

    Among 17 men who had received seemingly curative treatment for unilateral non-seminomatous germ cell tumors for the testis and who had consistently normal serum human chorionic gonadotropin (HCG) levels at a reference laboratory, 7 (41%) had at least one falsely positive commercial serum HCG determination. To investigate the cause of these falsely positive determinations the authors measured the cross reactivity of luteinizing hormone (LH) and follicle stimulating hormone (FSH) standards in the commercial HCG assay, and studied the relationships between commercial HCG levels and serum LH levels, serum FSH levels and gonadal status in men with and without normal gonadalmore » function. The falsely positive HCG determinations appeared to be due to elevated serum LH levels and cross reactivity of LH in the commercial HCG assay because: 1) there was substantial cross reactivity of the LH standards in the commercial assay, 2) the serum LH was elevated in four of six men with solitary testes, 3) there was a striking correlation between elevated serum LH levels and falsely elevated commercial HCG levels in ten men with solitary or absent testes, and 4) there were no falsely positive HCG determinations in 13 normal men but there were falsely positive HCG determinations in seven of ten anorchid men.« less

  3. Experimental investigation of false positive errors in auditory species occurrence surveys

    USGS Publications Warehouse

    Miller, David A.W.; Weir, Linda A.; McClintock, Brett T.; Grant, Evan H. Campbell; Bailey, Larissa L.; Simons, Theodore R.

    2012-01-01

    False positive errors are a significant component of many ecological data sets, which in combination with false negative errors, can lead to severe biases in conclusions about ecological systems. We present results of a field experiment where observers recorded observations for known combinations of electronically broadcast calling anurans under conditions mimicking field surveys to determine species occurrence. Our objectives were to characterize false positive error probabilities for auditory methods based on a large number of observers, to determine if targeted instruction could be used to reduce false positive error rates, and to establish useful predictors of among-observer and among-species differences in error rates. We recruited 31 observers, ranging in abilities from novice to expert, that recorded detections for 12 species during 180 calling trials (66,960 total observations). All observers made multiple false positive errors and on average 8.1% of recorded detections in the experiment were false positive errors. Additional instruction had only minor effects on error rates. After instruction, false positive error probabilities decreased by 16% for treatment individuals compared to controls with broad confidence interval overlap of 0 (95% CI: -46 to 30%). This coincided with an increase in false negative errors due to the treatment (26%; -3 to 61%). Differences among observers in false positive and in false negative error rates were best predicted by scores from an online test and a self-assessment of observer ability completed prior to the field experiment. In contrast, years of experience conducting call surveys was a weak predictor of error rates. False positive errors were also more common for species that were played more frequently, but were not related to the dominant spectral frequency of the call. Our results corroborate other work that demonstrates false positives are a significant component of species occurrence data collected by auditory methods. Instructing observers to only report detections they are completely certain are correct is not sufficient to eliminate errors. As a result, analytical methods that account for false positive errors will be needed, and independent testing of observer ability is a useful predictor for among-observer variation in observation error rates.

  4. False-positive cryptococcal antigen latex agglutination caused by disinfectants and soaps.

    PubMed Central

    Blevins, L B; Fenn, J; Segal, H; Newcomb-Gayman, P; Carroll, K C

    1995-01-01

    Five disinfectants or soaps were tested to determine if any could be responsible for false-positive results obtained with the Latex-Crypto Antigen Detection System kit (Immuno-Mycologics, Inc., Norman, Okla.). Three disinfectants or soaps (Derma soap, 7X, and Bacdown) produced false-positive agglutination after repeated washing of ring slides during testing of a known negative cerebrospinal fluid specimen. PMID:7650214

  5. Bladder cancer diagnosis with CT urography: test characteristics and reasons for false-positive and false-negative results.

    PubMed

    Trinh, Tony W; Glazer, Daniel I; Sadow, Cheryl A; Sahni, V Anik; Geller, Nina L; Silverman, Stuart G

    2018-03-01

    To determine test characteristics of CT urography for detecting bladder cancer in patients with hematuria and those undergoing surveillance, and to analyze reasons for false-positive and false-negative results. A HIPAA-compliant, IRB-approved retrospective review of reports from 1623 CT urograms between 10/2010 and 12/31/2013 was performed. 710 examinations for hematuria or bladder cancer history were compared to cystoscopy performed within 6 months. Reference standard was surgical pathology or 1-year minimum clinical follow-up. False-positive and false-negative examinations were reviewed to determine reasons for errors. Ninety-five bladder cancers were detected. CT urography accuracy: was 91.5% (650/710), sensitivity 86.3% (82/95), specificity 92.4% (568/615), positive predictive value 63.6% (82/129), and negative predictive value was 97.8% (568/581). Of 43 false positives, the majority of interpretation errors were due to benign prostatic hyperplasia (n = 12), trabeculated bladder (n = 9), and treatment changes (n = 8). Other causes include blood clots, mistaken normal anatomy, infectious/inflammatory changes, or had no cystoscopic correlate. Of 13 false negatives, 11 were due to technique, one to a large urinary residual, one to artifact. There were no errors in perception. CT urography is an accurate test for diagnosing bladder cancer; however, in protocols relying predominantly on excretory phase images, overall sensitivity remains insufficient to obviate cystoscopy. Awareness of bladder cancer mimics may reduce false-positive results. Improvements in CTU technique may reduce false-negative results.

  6. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    PubMed

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  7. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    PubMed Central

    2012-01-01

    Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals. PMID:22429706

  8. Development of Technologies for Early Detection and Stratification of Breast Cancer

    DTIC Science & Technology

    2012-10-01

    at the time of screening, and has an 8-10% false positive rate.3 These drawbacks lead to inaccurate patient diagnosis, which can allow potentially...95% recovery efficiency. Furthermore, using whole blood from healthy donors, we determined we have a zero false positive rate; that is, we have not...detected a single false positive event out of the dozen samples we ran. The technology we developed here is not only useful for the isolation of CTCs

  9. Evaluation of the Architect HIV Ag/Ab Combo Assay in a low-prevalence setting: The role of samples with a low S/CO ratio.

    PubMed

    Alonso, Roberto; Pérez-García, Felipe; Gijón, Paloma; Collazos, Ana; Bouza, Emilio

    2018-06-01

    The Architect HIV Ag/Ab Combo Assay, a fourth-generation ELISA, has proven to be highly reliable for the diagnosis of HIV infection. However, its high sensitivity may lead to false-positive results. To evaluate the diagnostic performance of Architect in a low-prevalence population and to assess the role of the sample-to-cutoff ratio (S/CO) in reducing the frequency of false-positive results. We conducted a retrospective study of samples analyzed by Architect between January 2015 and June 2017. Positive samples were confirmed by immunoblot (RIBA) or nucleic acid amplification tests (NAATs). Different S/CO thresholds (1, 2.5, 10, 25, and 100) were analyzed to determine sensitivity, specificity, and negative and positive predictive values (NPV, PPV). ROC analysis was used to determine the optimal S/CO. A total of 69,471 samples were analyzed. 709 (1.02%) were positive by Architect. Of these, 63 (8.89%) were false-positive results. Most of them (93.65%) were in samples with S/CO < 100. However, most confirmations by NAATs (12 out of 19 cases) were also recorded for these samples. The optimal S/CO was 2.5, which provided the highest area under the ROC curve (0.9998) and no false-negative results. With this S/CO, sensitivity and specificity were 100.0%, and PPV and NPV were 95.8% and 100.0%, respectively. In addition, the frequency of false-positive results decreased significantly to 4.15%. Although Architect generates a relatively high number of false-positive results, raising the S/CO limit too much to increase specificity can lead to false-negative results, especially in newly infected individuals. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Does disseminated nontuberculous mycobacterial disease cause false-positive Determine B-LAM lateral flow assay results? A retrospective review.

    PubMed

    Nel, Jeremy S; Lippincott, Christopher K; Berhanu, Rebecca; Spencer, David C; Sanne, Ian M; Ive, Prudence

    2017-06-02

    We retrospectively reviewed the Determine TB-LAM lateral flow assay (LF-LAM) results among HIV-infected patients with disseminated nontuberculous mycobacterial (NTM) disease. LF-LAM was positive in 19/21 patients without evidence of tuberculosis coinfection. Although tuberculosis-NTM coinfection may have been underdiagnosed, our results suggest that disseminated NTM disease may cause false-positive LF-LAM results. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  11. False-positive rate determination of protein target discovery using a covalent modification- and mass spectrometry-based proteomics platform.

    PubMed

    Strickland, Erin C; Geer, M Ariel; Hong, Jiyong; Fitzgerald, Michael C

    2014-01-01

    Detection and quantitation of protein-ligand binding interactions is important in many areas of biological research. Stability of proteins from rates of oxidation (SPROX) is an energetics-based technique for identifying the proteins targets of ligands in complex biological mixtures. Knowing the false-positive rate of protein target discovery in proteome-wide SPROX experiments is important for the correct interpretation of results. Reported here are the results of a control SPROX experiment in which chemical denaturation data is obtained on the proteins in two samples that originated from the same yeast lysate, as would be done in a typical SPROX experiment except that one sample would be spiked with the test ligand. False-positive rates of 1.2-2.2% and <0.8% are calculated for SPROX experiments using Q-TOF and Orbitrap mass spectrometer systems, respectively. Our results indicate that the false-positive rate is largely determined by random errors associated with the mass spectral analysis of the isobaric mass tag (e.g., iTRAQ®) reporter ions used for peptide quantitation. Our results also suggest that technical replicates can be used to effectively eliminate such false positives that result from this random error, as is demonstrated in a SPROX experiment to identify yeast protein targets of the drug, manassantin A. The impact of ion purity in the tandem mass spectral analyses and of background oxidation on the false-positive rate of protein target discovery using SPROX is also discussed.

  12. False Positive Probabilities for all Kepler Objects of Interest: 1284 Newly Validated Planets and 428 Likely False Positives

    NASA Astrophysics Data System (ADS)

    Morton, Timothy D.; Bryson, Stephen T.; Coughlin, Jeffrey L.; Rowe, Jason F.; Ravichandran, Ganesh; Petigura, Erik A.; Haas, Michael R.; Batalha, Natalie M.

    2016-05-01

    We present astrophysical false positive probability calculations for every Kepler Object of Interest (KOI)—the first large-scale demonstration of a fully automated transiting planet validation procedure. Out of 7056 KOIs, we determine that 1935 have probabilities <1% of being astrophysical false positives, and thus may be considered validated planets. Of these, 1284 have not yet been validated or confirmed by other methods. In addition, we identify 428 KOIs that are likely to be false positives, but have not yet been identified as such, though some of these may be a result of unidentified transit timing variations. A side product of these calculations is full stellar property posterior samplings for every host star, modeled as single, binary, and triple systems. These calculations use vespa, a publicly available Python package that is able to be easily applied to any transiting exoplanet candidate.

  13. 5 CFR 550.143 - Bases for determining positions for which premium pay under § 550.141 is authorized.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Bases for determining positions for which... Standby Duty Pay § 550.143 Bases for determining positions for which premium pay under § 550.141 is... isolation, or solely because the employee lives on the grounds. (2) The hours during which the requirement...

  14. 5 CFR 550.143 - Bases for determining positions for which premium pay under § 550.141 is authorized.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Bases for determining positions for which... Standby Duty Pay § 550.143 Bases for determining positions for which premium pay under § 550.141 is... isolation, or solely because the employee lives on the grounds. (2) The hours during which the requirement...

  15. Prescription drugs associated with false-positive results when using faecal immunochemical tests for colorectal cancer screening.

    PubMed

    Ibáñez-Sanz, Gemma; Garcia, Montse; Rodríguez-Moranta, Francisco; Binefa, Gemma; Gómez-Matas, Javier; Domènech, Xènia; Vidal, Carmen; Soriano, Antonio; Moreno, Víctor

    2016-10-01

    The most common side effect in population screening programmes is a false-positive result which leads to unnecessary risks and costs. To identify factors associated with false-positive results in a colorectal cancer screening programme with the faecal immunochemical test (FIT). Cross-sectional study of 472 participants with a positive FIT who underwent colonoscopy for confirmation of diagnosis between 2013 and 2014. A false-positive result was defined as having a positive FIT (≥20μg haemoglobin per gram of faeces) and follow-up colonoscopy without intermediate/high-risk lesions or cancer. Women showed a two-fold increased likelihood of a false-positive result compared with men (adjusted OR, 2.3; 95%CI, 1.5-3.4), but no female-specific factor was identified. The other variables associated with a false-positive result were successive screening (adjusted OR, 1.5; 95%CI, 1.0-2.2), anal disorders (adjusted OR, 3.1; 95%CI, 2.1-4.5) and the use of proton pump inhibitors (adjusted OR, 1.8; 95%CI, 1.1-2.9). Successive screening and proton pump inhibitor use were associated with FP in men. None of the other drugs were related to a false-positive FIT. Concurrent use of proton pump inhibitors at the time of FIT might increase the likelihood of a false-positive result. Further investigation is needed to determine whether discontinuing them could decrease the false-positive rate. Copyright © 2016 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  16. Working memory affects false memory production for emotional events.

    PubMed

    Mirandola, Chiara; Toffalini, Enrico; Ciriello, Alfonso; Cornoldi, Cesare

    2017-01-01

    Whereas a link between working memory (WM) and memory distortions has been demonstrated, its influence on emotional false memories is unclear. In two experiments, a verbal WM task and a false memory paradigm for negative, positive or neutral events were employed. In Experiment 1, we investigated individual differences in verbal WM and found that the interaction between valence and WM predicted false recognition, with negative and positive material protecting high WM individuals against false remembering; the beneficial effect of negative material disappeared in low WM participants. In Experiment 2, we lowered the WM capacity of half of the participants with a double task request, which led to an overall increase in false memories; furthermore, consistent with Experiment 1, the increase in negative false memories was larger than that of neutral or positive ones. It is concluded that WM plays a critical role in determining false memory production, specifically influencing the processing of negative material.

  17. 5 CFR 213.3301 - Positions of a confidential or policy-determining nature.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Positions of a confidential or policy-determining nature. 213.3301 Section 213.3301 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL... or policy-determining nature. (a) Upon specific authorization by OPM, agencies may make appointments...

  18. 5 CFR 213.3301 - Positions of a confidential or policy-determining nature.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Positions of a confidential or policy-determining nature. 213.3301 Section 213.3301 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL... or policy-determining nature. (a) Upon specific authorization by OPM, agencies may make appointments...

  19. 5 CFR 213.3301 - Positions of a confidential or policy-determining nature.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Positions of a confidential or policy-determining nature. 213.3301 Section 213.3301 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL... or policy-determining nature. (a) Upon specific authorization by OPM, agencies may make appointments...

  20. 5 CFR 213.3301 - Positions of a confidential or policy-determining nature.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Positions of a confidential or policy-determining nature. 213.3301 Section 213.3301 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL... or policy-determining nature. (a) Upon specific authorization by OPM, agencies may make appointments...

  1. 5 CFR 213.3301 - Positions of a confidential or policy-determining nature.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 1 2013-01-01 2013-01-01 false Positions of a confidential or policy-determining nature. 213.3301 Section 213.3301 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL... or policy-determining nature. (a) Upon specific authorization by OPM, agencies may make appointments...

  2. US women's attitudes to false positive mammography results and detection of ductal carcinoma in situ: cross sectional survey

    PubMed Central

    Schwartz, Lisa M; Woloshin, Steven; Sox, Harold C; Fischhoff, Baruch; Welch, H Gilbert

    2000-01-01

    Objective To determine women's attitudes to and knowledge of both false positive mammography results and the detection of ductal carcinoma in situ after screening mammography. Design Cross sectional survey. Setting United States. Participants 479 women aged 18-97 years who did not report a history of breast cancer. Main outcome measures Attitudes to and knowledge of false positive results and the detection of ductal carcinoma in situ after screening mammography. Results Women were aware that false positive results do occur. Their median estimate of the false positive rate for 10 years of annual screening was 20% (25th percentile estimate, 10%; 75th percentile estimate, 45%). The women were highly tolerant of false positives: 63% thought that 500 or more false positives per life saved was reasonable and 37% would tolerate 10 000 or more. Women who had had a false positive result (n=76) expressed the same high tolerance: 39% would tolerate 10 000 or more false positives. 62% of women did not want to take false positive results into account when deciding about screening. Only 8% of women thought that mammography could harm a woman without breast cancer, and 94% doubted the possibility of non-progressive breast cancers. Few had heard about ductal carcinoma in situ, a cancer that may not progress, but when informed, 60% of women wanted to take into account the possibility of it being detected when deciding about screening. Conclusions Women are aware of false positives and seem to view them as an acceptable consequence of screening mammography. In contrast, most women are unaware that screening can detect cancers that may never progress but feel that such information would be relevant. Education should perhaps focus less on false positives and more on the less familiar outcome of detection of ductal carcinoma in situ. PMID:10856064

  3. Consensus-based identification of factors related to false-positives in ultrasound scanning of synovitis and tenosynovitis.

    PubMed

    Ikeda, Kei; Narita, Akihiro; Ogasawara, Michihiro; Ohno, Shigeru; Kawahito, Yutaka; Kawakami, Atsushi; Ito, Hiromu; Matsushita, Isao; Suzuki, Takeshi; Misaki, Kenta; Ogura, Takehisa; Kamishima, Tamotsu; Seto, Yohei; Nakahara, Ryuichi; Kaneko, Atsushi; Nakamura, Takayuki; Henmi, Mihoko; Fukae, Jun; Nishida, Keiichiro; Sumida, Takayuki; Koike, Takao

    2016-01-01

    We aimed to identify causes of false-positives in ultrasound scanning of synovial/tenosynovial/bursal inflammation and provide corresponding imaging examples. We first performed systematic literature review to identify previously reported causes of false-positives. We next determined causes of false-positives and corresponding example images for educational material through Delphi exercises and discussion by 15 experts who were an instructor and/or a lecturer in the 2013 advanced course for musculoskeletal ultrasound organized by Japan College of Rheumatology Committee for the Standardization of Musculoskeletal Ultrasonography. Systematic literature review identified 11 articles relevant to sonographic false-positives of synovial/tenosynovial inflammation. Based on these studies, 21 candidate causes of false-positives were identified in the consensus meeting. Of these items, 11 achieved a predefined consensus (≥ 80%) in Delphi exercise and were classified as follows: (I) Gray-scale assessment [(A) non-specific synovial findings and (B) normal anatomical structures which can mimic synovial lesions due to either their low echogenicity or anisotropy]; (II) Doppler assessment [(A) Intra-articular normal vessels and (B) reverberation)]. Twenty-four corresponding examples with 49 still and 23 video images also achieved consensus. Our study provides a set of representative images that can help sonographers to understand false-positives in ultrasound scanning of synovitis and tenosynovitis.

  4. Interpreting the results of the Semmes-Weinstein monofilament test: accounting for false-positive answers in the international consensus on the diabetic foot protocol by a new model.

    PubMed

    Slater, Robert A; Koren, Shlomit; Ramot, Yoram; Buchs, Andreas; Rapoport, Micha J

    2014-01-01

    The Semmes-Weinstein monofilament is the most widely used test to diagnose the loss of protective sensation. The commonly used protocol of the International Consensus on the Diabetic Foot includes a 'sham' application that allows for false-positive answers. We sought to study the heretofore unexamined significance of false-positive answers. Forty-five patients with diabetes and a history of pedal ulceration (Group I) and 81 patients with diabetes but no history of ulceration (Group II) were studied. The three original sites of the International Consensus on the Diabetic Foot at the hallux, 1st metatarsal and 5th metatarsal areas were used. At each location, the test was performed three times: 2 actual and 1 "sham" applications. Scores were graded from 0 to 3 based upon correct responses. Determination of loss of protective sensation was performed with and without calculating a false-positive answer as a minus 1 score. False-positive responses were found in a significant percentage of patients with and without history of ulceration. Introducing false-positive results as minus 1 into the test outcome significantly increased the number of patients diagnosed with loss of protective sensation in both groups. False-positive answers can significantly affect Semmes-Weinstein monofilament test results and the diagnosis of LOPS. A model that accounts for false-positive answers is offered. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Cumulative Incidence of False-Positive Results in Repeated, Multimodal Cancer Screening

    PubMed Central

    Croswell, Jennifer Miller; Kramer, Barnett S.; Kreimer, Aimee R.; Prorok, Phil C.; Xu, Jian-Lun; Baker, Stuart G.; Fagerstrom, Richard; Riley, Thomas L.; Clapp, Jonathan D.; Berg, Christine D.; Gohagan, John K.; Andriole, Gerald L.; Chia, David; Church, Timothy R.; Crawford, E. David; Fouad, Mona N.; Gelmann, Edward P.; Lamerato, Lois; Reding, Douglas J.; Schoen, Robert E.

    2009-01-01

    PURPOSE Multiple cancer screening tests have been advocated for the general population; however, clinicians and patients are not always well-informed of screening burdens. We sought to determine the cumulative risk of a false-positive screening result and the resulting risk of a diagnostic procedure for an individual participating in a multimodal cancer screening program. METHODS Data were analyzed from the intervention arm of the ongoing Prostate, Lung, Colorectal, and Ovarian (PLCO) Cancer Screening Trial, a randomized controlled trial to determine the effects of prostate, lung, colorectal, and ovarian cancer screening on disease-specific mortality. The 68,436 participants, aged 55 to 74 years, were randomized to screening or usual care. Women received serial serum tests to detect cancer antigen 125 (CA-125), transvaginal sonograms, posteroanterior-view chest radiographs, and flexible sigmoidoscopies. Men received serial chest radiographs, flexible sigmoidoscopies, digital rectal examinations, and serum prostate-specific antigen tests. Fourteen screening examinations for each sex were possible during the 3-year screening period. RESULTS After 14 tests, the cumulative risk of having at least 1 false-positive screening test is 60.4% (95% CI, 59.8%–61.0%) for men, and 48.8% (95% CI, 48.1%–49.4%) for women. The cumulative risk after 14 tests of undergoing an invasive diagnostic procedure prompted by a false-positive test is 28.5% (CI, 27.8%–29.3%) for men and 22.1% (95% CI, 21.4%–22.7%) for women. CONCLUSIONS For an individual in a multimodal cancer screening trial, the risk of a false-positive finding is about 50% or greater by the 14th test. Physicians should educate patients about the likelihood of false positives and resulting diagnostic interventions when counseling about cancer screening. PMID:19433838

  6. The health system impact of false positive newborn screening results for medium-chain acyl-CoA dehydrogenase deficiency: a cohort study.

    PubMed

    Karaceper, Maria D; Chakraborty, Pranesh; Coyle, Doug; Wilson, Kumanan; Kronick, Jonathan B; Hawken, Steven; Davies, Christine; Brownell, Marni; Dodds, Linda; Feigenbaum, Annette; Fell, Deshayne B; Grosse, Scott D; Guttmann, Astrid; Laberge, Anne-Marie; Mhanni, Aizeddin; Miller, Fiona A; Mitchell, John J; Nakhla, Meranda; Prasad, Chitra; Rockman-Greenberg, Cheryl; Sparkes, Rebecca; Wilson, Brenda J; Potter, Beth K

    2016-02-03

    There is no consensus in the literature regarding the impact of false positive newborn screening results on early health care utilization patterns. We evaluated the impact of false positive newborn screening results for medium-chain acyl-CoA dehydrogenase deficiency (MCADD) in a cohort of Ontario infants. The cohort included all children who received newborn screening in Ontario between April 1, 2006 and March 31, 2010. Newborn screening and diagnostic confirmation results were linked to province-wide health care administrative datasets covering physician visits, emergency department visits, and inpatient hospitalizations, to determine health service utilization from April 1, 2006 through March 31, 2012. Incidence rate ratios (IRRs) were used to compare those with false positive results for MCADD to those with negative newborn screening results, stratified by age at service use. We identified 43 infants with a false positive newborn screening result for MCADD during the study period. These infants experienced significantly higher rates of physician visits (IRR: 1.42) and hospitalizations (IRR: 2.32) in the first year of life relative to a screen negative cohort in adjusted analyses. Differences in health services use were not observed after the first year of life. The higher use of some health services among false positive infants during the first year of life may be explained by a psychosocial impact of false positive results on parental perceptions of infant health, and/or by differences in underlying health status. Understanding the impact of false positive newborn screening results can help to inform newborn screening programs in designing support and education for families. This is particularly important as additional disorders are added to expanded screening panels, yielding important clinical benefits for affected children but also a higher frequency of false positive findings.

  7. Comparison of bronchoalveolar lavage cytology and transbronchial biopsy in the diagnosis of carcinoma of lung.

    PubMed

    Ahmed, Ayesha; Ahmed, Sajjad

    2004-01-01

    The objectives of this study were to compare bronchoalveolar lavage (BAL) cytology and transbronchial biopsy in the diagnosis of carcinoma lung and to determine accuracy of BAL cytology using histopathlologic examination of transbronchial biopsy as gold standard at our center. This study was carried out at Department of Histopathology, Ayub Medical College, Abbottabad, from 1.09.2000 to 28.02.2003. BAL fluid and bronchial biopsy were received and processed simultaneously. Four cytology and a set of histopathology slides were prepared. These were screened and diagnosis recorded. Sensitivity, Specificity, False Positive, False Negative, Positive predictive value and Negative predictive value of BAL cytology were determined using histopathology of transbronchial biopsy as gold standard. We found the sensitivity of BAL cytology to be 93.44% as compared with transbronchial biopsy. The specificity was 100%. There was no false positive while false negative results were 6.55 %. The positive predictive value was 100 %, while the negative predictive value was 75 %. The overall diagnostic efficacy of BAL cytology was 94.52 %. BAL cytology is a highly sensitive and specific test for diagnosis of carcinoma lung. It can be used as a quick and reliable diagnostic method for diagnosis of lung malignancy.

  8. Analysis of false results in a series of 835 fine needle aspirates of breast lesions.

    PubMed

    Willis, S L; Ramzy, I

    1995-01-01

    To analyze cases of false diagnoses from a large series to help increase the accuracy of fine needle aspiration of palpable breast lesions. The results of FNA of 835 palpable breast lesions were analyzed to determine the reasons for false positive, false negative and false suspicious diagnoses. Of the 835 aspirates, 174 were reported as positive, 549 as negative and 66 as suspicious or atypical but not diagnostic of malignancy. Forty-six cases were considered unsatisfactory. Tissue was available for comparison in 286 cases. The cytologic diagnoses in these cases were reported as follows: positive, 125 (43.7%); suspicious, 33 (11.5%); atypical, 18 (6.2%); negative, 92 (32%); and unsatisfactory, 18 (6.2%). There was one false positive diagnosis, yielding a false positive rate of 0.8%. This lesion was a case of fibrocystic change with hyperplasia, focal fat necrosis and reparative atypia. There were 14 false negative cases, resulting in a false negative rate of 13.2%. Nearly all these cases were sampling errors and included infiltrating ductal carcinomas (9), ductal carcinomas in situ (2), infiltrating lobular carcinomas (2) and tubular carcinoma (1). Most of the suspicious and atypical lesions proved to be carcinomas (35/50). The remainder were fibroadenomas (6), fibrocystic change (4), gynecomastia (2), adenosis (2) and granulomatous mastitis (1). A positive diagnosis of malignancy by FNA is reliable in establishing the diagnosis and planning the treatment of breast cancer. The false-positive rate is very low, with only a single case reported in 835 aspirates. Most false negatives are due to sampling and not to interpretive difficulties. The category "suspicious but not diagnostic of malignancy" serves a useful purpose in management of patients with breast lumps.

  9. False Positives in Exoplanet Detection

    NASA Astrophysics Data System (ADS)

    Leuquire, Jacob; Kasper, David; Jang-Condell, Hannah; Kar, Aman; Sorber, Rebecca; Suhaimi, Afiq; KELT (Kilodegree Extremely Little Telescope)

    2018-06-01

    Our team at the University of Wyoming uses a 0.6 m telescope at RBO (Red Buttes Observatory) to help confirm results on potential exoplanet candidates from low resolution, wide field surveys shared by the KELT (Kilodegree Extremely Little Telescope) team. False positives are common in this work. We carry out transit photometry, and this method comes with special types of false positives. The most common false positive seen at the confirmation level is an EB (eclipsing binary). Low resolution images are great in detecting multiple sources for photometric dips in light curves, but they lack the precision to decipher single targets at an accurate level. For example, target star KC18C030621 needed RBO’s photometric precision to determine there was a nearby EB causing exoplanet type light curves. Identifying false positives with our telescope is important work because it helps eliminate the waste of time taken by more expensive telescopes trying to rule out negative candidate stars. It also furthers the identification of other types of photometric events, like eclipsing binaries, so they can be studied on their own.

  10. Analyzing False Positives of Four Questions in the Force Concept Inventory

    ERIC Educational Resources Information Center

    Yasuda, Jun-ichro; Mae, Naohiro; Hull, Michael M.; Taniguchi, Masa-aki

    2018-01-01

    In this study, we analyze the systematic error from false positives of the Force Concept Inventory (FCI). We compare the systematic errors of question 6 (Q.6), Q.7, and Q.16, for which clearly erroneous reasoning has been found, with Q.5, for which clearly erroneous reasoning has not been found. We determine whether or not a correct response to a…

  11. Biological Evaluation of Methods for the Determination of Free Available Chlorine.

    DTIC Science & Technology

    1980-03-01

    tri • :., t at pH 6.0, 20’C. Lowest C1 level for false positive, mg/l Chloramine Species Test NH2CI NHC1 2 NCI1 DPDT 4.8 b 0.8 DPDTSF 4.8 b 0.6 DPDP 1.1...Available Chlorine Chlorine Membrane Electrode T )PD FACTS biofac Amperometric titration 20. ASIST’IACT C’ntAtmoe so &eJie .b f nerandm Idenwlry by block...methods tested yielded false positive determinations of free chlorine with one or more of the inorganic chloramines . The FACTS procedure was the most

  12. Retrospective imaging study on the diagnosis of pathological false positive iodine-131 scans in patients with thyroid cancer.

    PubMed

    Jia, Qiang; Meng, Zhaowei; Tan, Jian; Zhang, Guizhi; He, Yajing; Sun, Haoran; Yu, Chunshui; Li, Dong; Zheng, Wei; Wang, Renfei; Wang, Shen; Li, Xue; Zhang, Jianping; Hu, Tianpeng; Liu, N A; Upadhyaya, Arun

    2015-11-01

    Iodine-131 (I-131) therapy and post-therapy I-131 scanning are essential in the management of differentiated thyroid cancer (DTC). However, pathological false positive I-131 scans can lead to misdiagnosis and inappropriate I-131 treatment. This retrospective study aimed to investigate the best imaging modality for the diagnosis of pathological false positive I-131 scans in a DTC patient cohort, and to determine its incidence. DTC patient data archived from January 2008 to January 2010 was retrieved. Post-therapeutic I-131 scans were conducted and interpreted. The imaging modalities of magnetic resonance imaging (MRI), computed tomography and ultrasonography were applied and compared to check all suspected lesions. Biopsy or needle aspiration was conducted for patients who consented to the acquisition of histopathological confirmation. Data for 156 DTC patients were retrieved. Only 6 cases of pathological false-positives were found among these (incidence, 3.85%), which included 3 cases of thymic hyperplasia in the mediastinum, 1 case of pleomorphic adenoma in the parapharyngeal space and 1 case of thyroglossal duct cyst in the neck. MRI was demonstrated as the best imaging modality for diagnosis due to its superior soft tissue resolution. However, no imaging modality was able to identify the abdominal false positive-lesions observed in 2 cases, one of whom also had thymic hyperplasia. In conclusion, pathological false positive I-131 scans occurred with an incidence of 3.85%. MRI was the best imaging modality for diagnosing these pathological false-positives.

  13. Impacting the effect of fMRI noise through hardware and acquisition choices - Implications for controlling false positive rates.

    PubMed

    Wald, Lawrence L; Polimeni, Jonathan R

    2017-07-01

    We review the components of time-series noise in fMRI experiments and the effect of image acquisition parameters on the noise. In addition to helping determine the total amount of signal and noise (and thus temporal SNR), the acquisition parameters have been shown to be critical in determining the ratio of thermal to physiological induced noise components in the time series. Although limited attention has been given to this latter metric, we show that it determines the degree of spatial correlations seen in the time-series noise. The spatially correlations of the physiological noise component are well known, but recent studies have shown that they can lead to a higher than expected false-positive rate in cluster-wise inference based on parametric statistical methods used by many researchers. Based on understanding the effect of acquisition parameters on the noise mixture, we propose several acquisition strategies that might be helpful reducing this elevated false-positive rate, such as moving to high spatial resolution or using highly-accelerated acquisitions where thermal sources dominate. We suggest that the spatial noise correlations at the root of the inflated false-positive rate problem can be limited with these strategies, and the well-behaved spatial auto-correlation functions (ACFs) assumed by the conventional statistical methods are retained if the high resolution data is smoothed to conventional resolutions. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. 10 CFR 26.103 - Determining a confirmed positive test result for alcohol.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Determining a confirmed positive test result for alcohol. 26.103 Section 26.103 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting... fitness indicates that the donor is fit to safely and competently perform his or her duties. ...

  15. 10 CFR 26.103 - Determining a confirmed positive test result for alcohol.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Determining a confirmed positive test result for alcohol. 26.103 Section 26.103 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting... fitness indicates that the donor is fit to safely and competently perform his or her duties. ...

  16. 10 CFR 26.103 - Determining a confirmed positive test result for alcohol.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Determining a confirmed positive test result for alcohol. 26.103 Section 26.103 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting... fitness indicates that the donor is fit to safely and competently perform his or her duties. ...

  17. 10 CFR 26.103 - Determining a confirmed positive test result for alcohol.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Determining a confirmed positive test result for alcohol. 26.103 Section 26.103 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting... fitness indicates that the donor is fit to safely and competently perform his or her duties. ...

  18. 10 CFR 26.103 - Determining a confirmed positive test result for alcohol.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Determining a confirmed positive test result for alcohol. 26.103 Section 26.103 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Collecting... fitness indicates that the donor is fit to safely and competently perform his or her duties. ...

  19. Effects of positive results for Mycobacterium avium subsp paratuberculosis as determined by microbial culture of feces or antibody ELISA on results of caudal fold tuberculin test and interferon-gamma assay for tuberculosis in cattle.

    PubMed

    Dunn, John R; Kaneene, John B; Grooms, Daniel L; Bolin, Steven R; Bolin, Carole A; Bruning-Fann, Colleen S

    2005-02-01

    To determine whether cattle testing positive for Mycobacterium avium subsp paratuberculosis as determined by microbial culture of feces or antibody ELISA were more likely to have false-positive responses on the caudal fold tuberculin (CFT) test or interferon-gamma (IFN-gamma) assay for Mycobacterium bovis than cattle testing negative for M paratuberculosis. 1043 cattle from 10 herds in Michigan. Feces and blood samples for plasma were collected from cattle > or =24 months old on the day the CFT test was read. Fecal samples were submitted for microbial culture for M paratuberculosis. Plasma samples were tested for antibody against M paratuberculosis, and IFN-gamma after stimulation with purified protein derivative tuberculin from M bovis or M avium. Of 1043 cattle, 180 (17.3%) had positive CFT test results (suspects) and 8 (0.8%) had positive IFN-gamma assay results after stimulation with purified protein derivative tuberculin from M bovis. Forty-five (4.3%) and 115 (11.0%) cattle tested positive for M paratuberculosis as determined by microbial culture of feces and antibody ELISA, respectively. Cattle with positive responses for M paratuberculosis appeared to have an increased likelihood of false-positive results on the CFT test, although this association was not significant. No significant association was detected among cattle testing positive for M paratuberculosis as determined by microbial culture of feces and antibody ELISA and positive CFT test and IFN-gamma assay results for M bovis.

  20. 25 CFR 63.14 - What positions require a background investigation and determination of suitability for employment...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false What positions require a background investigation and determination of suitability for employment or retention? 63.14 Section 63.14 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR TRIBAL GOVERNMENT INDIAN CHILD PROTECTION AND FAMILY VIOLENCE PREVENTION Minimum...

  1. False-Positive Rate of AKI Using Consensus Creatinine-Based Criteria.

    PubMed

    Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G S; Negoianu, Dan; Testani, Jeffrey M; Berns, Jeffrey S; Parikh, Chirag R; Wilson, F Perry

    2015-10-07

    Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false-positive rates because of inherent laboratory and biologic variabilities of creatinine. We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false-positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient's true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false-positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%-8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false-positive AKI diagnosis rate of 30.5% (interquartile range =30.1%-30.9%) versus 2.0% (interquartile range =1.9%-2.1%) in patients with true serum creatinine values <1.5 mg/dl (P<0.001). Use of small serum creatinine changes to diagnose AKI is limited by high false-positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. Copyright © 2015 by the American Society of Nephrology.

  2. False-positive IgM for CMV in pregnant women with autoimmune disease: a novel prognostic factor for poor pregnancy outcome.

    PubMed

    De Carolis, S; Santucci, S; Botta, A; Garofalo, S; Martino, C; Perrelli, A; Salvi, S; Degennaro, Va; de Belvis, Ag; Ferrazzani, S; Scambia, G

    2010-06-01

    Our aims were to assess the frequency of false-positive IgM antibodies for cytomegalovirus in pregnant women with autoimmune diseases and in healthy women (controls) and to determine their relationship with pregnancy outcome. Data from 133 pregnancies in 118 patients with autoimmune diseases and from 222 pregnancies in 198 controls were assessed. When positive IgM for cytomegalovirus was detected, IgG avidity, cytomegalovirus isolation and polymerase chain reaction for CMV-DNA in maternal urine and amniotic fluid samples were performed in order to identify primary infection or false positivity. A statistically significantly higher rate of false-positive IgM was found in pregnancies with autoimmune diseases (16.5%) in comparison with controls (0.9%). A worse pregnancy outcome was observed among patients with autoimmune disease and false cytomegalovirus IgM in comparison with those without false positivity: earlier week of delivery (p = 0.017), lower neonatal birth weight (p = 0.0004) and neonatal birth weight percentile (p = 0.002), higher rate of intrauterine growth restriction (p = 0.02) and babies weighing less than 2000 g (p = 0.025) were encountered. The presence of false cytomegalovirus IgM in patients with autoimmune diseases could be used as a novel prognostic index of poor pregnancy outcome: it may reflect a non-specific activation of the immune system that could negatively affect pregnancy outcome. Lupus (2010) 19, 844-849.

  3. Reliability of roentgenogram evaluation of pedicle screw position.

    PubMed

    Ferrick, M R; Kowalski, J M; Simmons, E D

    1997-06-01

    This was a human cadaver study of the accuracy of biplanar roentgenography in determining pedicle screw position. To determine the independent accuracy of radiologic evaluation of screw placement and to determine if there are any particular screw malpositions that are more likely to produce a false sense of acceptable screw position. Other investigators have reported the correlation between radiologic evaluation and anatomic dissection. However, in those studies the radiologic evaluation was not independent of the surgeons placing the screws. There has been no comment in the literature regarding particular screw malpositions that would lead the surgeon into a false sense of successful screw placement. Pedicle screws were placed in cadaver spines, and biplanar roentgenograms of the specimens were evaluated by independent observers. The results of the roantgenogram evaluation then were compared to those of the anatomic dissection. The accuracy of roentgenogram evaluation varied from 73% to 83%, depending on the experience of the surgeon grading the roentgenograms. Screws misplaced medially into the spinal canal are more likely to give the surgeon a false sense of successful screw placement. The surgeon must not rely solely on the roentgenograms, but instead continue to use tactile sensory skills, anatomic knowledge, and additional modalities such as electromyography monitoring.

  4. Quality control in molecular immunohistochemistry

    PubMed Central

    2008-01-01

    Immunoperoxidase histochemistry is a widespread method of assessing expression of biomolecules in tissue samples. Accurate assessment of the expression levels of genes is critical for the management of disease, particularly as therapy targeted to specific molecules becomes more widespread. Determining the quality of preservation of macromolecules in tissue is important to avoid false negative and false positive results. In this review we discuss (1) issues of sensitivity (false negativity) and specificity (false positivity) of immunohistochemical stains, (2) approaches to better understanding differences in immunostains done by different laboratories (including the recently proposed MISFISHIE specification for tissue localization studies), and (3) approaches to assessing the quality of preservation of macromolecules in tissue, particularly in small biopsy samples. PMID:18648842

  5. The diagnostic significance of lactate dehydrogenase isoenzymes in urinary cytology.

    PubMed Central

    Nishikawa, A.; Tanaka, T.; Takeuchi, T.; Fujihiro, S.; Mori, H.

    1991-01-01

    Lactate dehydrogenase (LDH) isoenzyme distribution was examined in 106 urine samples being tested cytologically for evidence of bladder cancer; the samples were selected to have less than 20 leucocytes and erythrocytes per high power field and the LDH pattern determined by electrophoresis. The Papanicolaou stained-smears showed 68 negative, 17 suspicious and 21 positive. The LDH M-fraction of the urinary supernatant in cytologically positive cases was significantly greater than in negative cases, although the latter included a few false negative samples. Some of the false negatives gave positive results for the LDH M-fraction; these results suggest that the determination of LDH isoenzymes in the urine is useful in diagnosing urinary tract cancers, including early stage, and for follow-up of patients with bladder cancers after surgical resection. PMID:2039708

  6. Comparison of multiple methods for the determination of sulphite in Allium and Brassica vegetables

    PubMed Central

    Robbins Carlos, Katherine S.; de Jager, Lowri S.

    2018-01-01

    Sulphites are a family of additives regulated for use worldwide in food products. They must be declared on the label if they are present in concentrations greater than 10 mg kg−1, determined as sulphur dioxide (SO2). The current US regulatory method for sulphites, the optimised Monier–Williams method (OMW), produces false-positive results with vegetables from the Allium (garlic) and Brassica (cabbage) genera due to extraction conditions that are thought to cause endogenous sulphur compounds to release SO2. Recently, modifications to the OMW method (2× MW) were published that reportedly reduced this false-positive in garlic. However, no other vegetables from these genera have been investigated. In addition, an LC-MS/MS method was developed for sulphite analysis, but it has not yet been tested with these problematic matrices. Ten vegetable species were analysed using these sulphite methods (OMW titration, OMW gravimetric, 2× MW and LC-MS/MS) to determine the false-positive rate. Sulphite concentrations > 10 mg kg−1 SO2 were observed with the OMW analyses. The 2× MW method reduced the measured concentration in unsulphited samples to ≤ 10 mg kg−1 SO2 for all matrices analysed. The LC-MS/MS method showed concentrations < 10 mg kg−1 for the Brassica samples, but only displayed a slight reduction in the Allium matrices. Spiked recovery studies were conducted to determine if these methods can detect added sulphite. The 2× MW had recoveries of 17% and 42% for water and fresh garlic, respectively, and the LC-MS/MS had recoveries of 108%, 125%, 116% and 107% for water, fresh garlic, roasted garlic, and hummus, respectively. The low recoveries of the 2× MW may indicate that sulphur compounds cannot be properly quantified with this method. The ability to eliminate false-positives will enable accurate determination of added sulphite to ensure compliance with sulphite labelling requirements. PMID:27592824

  7. 14 CFR 25.1389 - Position light distribution and intensities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... provided by new equipment with light covers and color filters in place. Intensities must be determined with... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Position light distribution and intensities... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1389 Position...

  8. 14 CFR 27.1389 - Position light distribution and intensities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... provided by new equipment with light covers and color filters in place. Intensities must be determined with... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Position light distribution and intensities... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Lights § 27.1389 Position...

  9. 14 CFR 27.1389 - Position light distribution and intensities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... provided by new equipment with light covers and color filters in place. Intensities must be determined with... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Position light distribution and intensities... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Lights § 27.1389 Position...

  10. 14 CFR 25.1389 - Position light distribution and intensities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... provided by new equipment with light covers and color filters in place. Intensities must be determined with... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Position light distribution and intensities... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1389 Position...

  11. 14 CFR 27.1389 - Position light distribution and intensities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... provided by new equipment with light covers and color filters in place. Intensities must be determined with... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Position light distribution and intensities... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Lights § 27.1389 Position...

  12. 14 CFR 25.1389 - Position light distribution and intensities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... provided by new equipment with light covers and color filters in place. Intensities must be determined with... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Position light distribution and intensities... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1389 Position...

  13. 14 CFR 25.1389 - Position light distribution and intensities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... provided by new equipment with light covers and color filters in place. Intensities must be determined with... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Position light distribution and intensities... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Equipment Lights § 25.1389 Position...

  14. 14 CFR 27.1389 - Position light distribution and intensities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... provided by new equipment with light covers and color filters in place. Intensities must be determined with... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Position light distribution and intensities... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Equipment Lights § 27.1389 Position...

  15. Hemorrhoids detected at colonoscopy: an infrequent cause of false-positive fecal immunochemical test results.

    PubMed

    van Turenhout, Sietze T; Oort, Frank A; Terhaar sive Droste, Jochim S; Coupé, Veerle M H; van der Hulst, Rene W; Loffeld, Ruud J; Scholten, Pieter; Depla, Annekatrien C T M; Bouman, Anneke A; Meijer, Gerrit A; Mulder, Chris J J; van Rossum, Leo G M

    2012-07-01

    Colorectal cancer screening by fecal immunochemical tests (FITs) is hampered by frequent false-positive (FP) results and thereby the risk of complications and strain on colonoscopy capacity. Hemorrhoids might be a plausible cause of FP results. To determine the contribution of hemorrhoids to the frequency of FP FIT results. Retrospective analysis from prospective cohort study. Five large teaching hospitals, including 1 academic hospital. All subjects scheduled for elective colonoscopy. FIT before bowel preparation. Frequency of FP FIT results in subjects with hemorrhoids as the only relevant abnormality compared with FP FIT results in subjects with no relevant abnormalities. Logistic regression analysis to determine colonic abnormalities influencing FP results. In 2855 patients, 434 had positive FIT results: 213 had advanced neoplasia and 221 had FP results. In 9 individuals (4.1%; 95% CI, 1.4-6.8) with an FP FIT result, hemorrhoids were the only abnormality. In univariate unadjusted analysis, subjects with hemorrhoids as the only abnormality did not have more positive results (9/134; 6.7%) compared with subjects without any abnormalities (43/886; 4.9%; P = .396). Logistic regression identified hemorrhoids, nonadvanced polyps, and a group of miscellaneous abnormalities, all significantly influencing false positivity. Of 1000 subjects with hemorrhoids, 67 would have FP results, of whom 18 would have FP results because of hemorrhoids only. Potential underreporting of hemorrhoids; high-risk individuals. Hemorrhoids in individuals participating in colorectal cancer screening will probably not lead to a substantial number of false-positive test results. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  16. Test Performance and Test-Retest Reliability of the Vestibular/Ocular Motor Screening and King-Devick Test in Adolescent Athletes During a Competitive Sport Season.

    PubMed

    Worts, Phillip R; Schatz, Philip; Burkhart, Scott O

    2018-05-01

    The Vestibular/Ocular Motor Screening (VOMS) and King-Devick (K-D) test are tools designed to assess ocular or vestibular function after a sport-related concussion. To determine the test-retest reliability and rate of false-positive results of the VOMS and K-D test in a healthy athlete sample. Cohort study (diagnosis); Level of evidence, 2. Forty-five healthy high school student-athletes (mean age, 16.11 ± 1.43 years) completed self-reported demographics and medical history and were administered the VOMS and K-D test during rest on day 1 (baseline). The VOMS and K-D test were administered again once during rest (prepractice) and once within 5 minutes of removal from sport practice on day 2 (removal). The Borg rating of perceived exertion scale was administered at removal. Intraclass correlation coefficients were used to determine test-retest reliability on the K-D test and the average near point of convergence (NPC) distance on the VOMS. Level of agreement was used to examine VOMS symptom provocation over the 3 administration times. Multivariate base rates were used to determine the rate of false-positive results when simultaneously considering multiple clinical cutoffs. Test-retest reliability of total time on the K-D test (0.91 [95% CI, 0.86-0.95]) and NPC distance (0.91 [95% CI, 0.85-0.95]) was high across the 3 administration times. Level of agreement ranged from 48.9% to 88.9% across all 3 times for the VOMS items. Using established clinical cutoffs, false-positive results occurred in 2% of the sample using the VOMS at removal and 36% using the K-D test. The VOMS displayed a false-positive rate of 2% in this high school student-athlete cohort. The K-D test's false-positive rate was 36% while maintaining a high level of test-retest reliability (0.91). Results from this study support future investigation of VOMS administration in an acutely injured high school athletic sample. Going forward, the VOMS may be more stable than other neurological and symptom report screening measures and less vulnerable to false-positive results than the K-D test.

  17. Accuracy of BRT and Delvotest microbial inhibition tests as affected by composition of ewe's milk.

    PubMed

    Althaus, Rafael; Torres, Antonio; Peris, Cristofol; Beltran, M Carmen; Fernandez, Nemesio; Molina, M Pilar

    2003-03-01

    The presence of drug residues in ewe's milk samples can be determined by microbial assays. The main limitation of these tests is the large number of false-positive results associated with them. False-positive results can be explained by the interaction of certain substances naturally existing in ewe's milk with the growth of the microorganism used in the test. In this study, milk chemical composition (fat, protein, lactose, total solids), somatic cell counts (SCCs), free fatty acid concentrations, and lactoperoxidase system components were determined in order to investigate their influence on the rate of false-positive results for the BRT and Delvotest microbiological inhibitor tests. Milk samples were obtained after morning milking of Manchega ewes at 15, 30, 45, 60, 75, 90, 105, 120, and 135 days after parturition. The animals did not receive any kind of treatment or medicated feed throughout the experiment. The false-positive rates for BRT and Delvotest were 3.75 and 2.4%, respectively. When the logistic regression model was applied, the percentages of total solids for positive samples were significantly different from those for negative samples (16.90 versus 18.42% for BRT, 16.05 versus 18.45% for Delvotest), while the SCC logarithmic transformation was significantly higher for the positive samples than for the negative samples (5.38 versus 5.11 log units for BRT, 5.32 versus 5.11 log units for Delvotest). Moreover, Delvotest-positive samples exhibited thiocyanate concentrations higher than those of Delvotest-negative samples (8.18 mg/liter versus 6.85 mg/liter). Further analyses are needed to confirm the possible presence of antimicrobial residues in this particular type of milk sample.

  18. [Analysis for Discordance of Positive and Negative Blood Typing by Gel Card].

    PubMed

    Li, Cui-Ying; Xu, Hong; Lei, Hui-Fen; Liu, Juan; Li, Xiao-Wei

    2017-08-01

    To explore the method of Gel card identifying ABO blood group, determine the inconsistent cause and the distribution of disease affecting factors, and put forward a method of its solutions. To collect 240 positive and negative typing-discordant blood speciments from patients examined by Gel card and send these speciments to blood type reference laboratory for examining with the classic tube method and serological test, such as salivary blood-group substance, in order to performe genotyping method when serologic test can not be determined. Among 240 positive and negative typing-discordant blood speciments from patients examined by Gel card, 107 blood speciments were positive and negative consistent examined by false agglutination test (44.58%), 133 blood specinents were discordent examined by false agglutination (55.42%), out of them, 35 cases (14.58%) with inconsistent cold agglutination test, 22 cases (9.17%) with weakened AB antigenicity, 16 cases (6.67%) with ABO subtyping, 12 cases (5.00%) with positive direct antiglobulin test, 11 cases (4.58%) with reduced or without antibodies, 11 cases (4.58%) with false aggregation caused by drugs or protein, 11 cases (4.58%) with salivary blood-type substances, 8 cases (3.33%) with non-ABO alloantibody, and 7 cases (2.92%) with allogeneic bone marrow transplantation. The distribution of disease were following: blood disease (16.83%), tumor (11.88%), and cardiopulmonary diseases (11.39%); chi-square test results indicated that the distribution significantly different. The analysis of ABO blood grouping shows a variety factors influencing positive and negative blood typing, and the Gel Card identification can produc more false positive blood types. Therefore, more attention should be paid on the high incidence diseases, such as blood disease, tumor, and cardiopulmonary disease.

  19. Analysis of sentinel node positivity in primary cutaneous melanoma: an 8-year single institution experience.

    PubMed

    Joyce, K M; McInerney, N M; Piggott, R P; Martin, F; Jones, D M; Hussey, A J; Kerin, M J; Kelly, J L; Regan, P J

    2017-11-01

    Sentinel lymph node biopsy (SLNB) is a standard method for determining the pathologic status of the regional lymph nodes. The aim of our study was to determine the incidence and clinicopathologic factors predictive of SLN positivity, and to evaluate the prognostic importance of SLNB in patients with cutaneous melanoma. We performed a retrospective analysis of a prospectively maintained database of all patients who underwent SLNB for primary melanoma at our institution from 2005 to 2012. Statistical analysis was performed using χ 2 and Fischer exact test. In total, 318 patients underwent SLNB, of which 65 were for thin melanoma (≤1 mm). There were 36 positive SLNB, 278 negative SLNB and in four cases the SLN was not located. The incidence rate for SLNB was 11.3% overall and 1.5% in thin melanomas alone. Statistical analysis identified Breslow thickness >1 mm (P = 0.006), Clark level ≥ IV (P = 0.004) and age <75 years (P = 0.035) as the strongest predictors of SLN positivity. Our overall false negativity rate was 20% (9/45) with one case of false-negative SLNB in thin melanomas. Breslow thickness of the primary tumour remains the strongest predictor of SLN positivity. Our findings point to a possible limited role for SLNB in thin melanoma due to its low positivity rate, associated false-negative rate and related morbidity.

  20. False positive circumsporozoite protein ELISA: a challenge for the estimation of the entomological inoculation rate of malaria and for vector incrimination

    PubMed Central

    2011-01-01

    Background The entomological inoculation rate (EIR) is an important indicator in estimating malaria transmission and the impact of vector control. To assess the EIR, the enzyme-linked immunosorbent assay (ELISA) to detect the circumsporozoite protein (CSP) is increasingly used. However, several studies have reported false positive results in this ELISA. The false positive results could lead to an overestimation of the EIR. The aim of present study was to estimate the level of false positivity among different anopheline species in Cambodia and Vietnam and to check for the presence of other parasites that might interact with the anti-CSP monoclonal antibodies. Methods Mosquitoes collected in Cambodia and Vietnam were identified and tested for the presence of sporozoites in head and thorax by using CSP-ELISA. ELISA positive samples were confirmed by a Plasmodium specific PCR. False positive mosquitoes were checked by PCR for the presence of parasites belonging to the Haemosporidia, Trypanosomatidae, Piroplasmida, and Haemogregarines. The heat-stability and the presence of the cross-reacting antigen in the abdomen of the mosquitoes were also checked. Results Specimens (N = 16,160) of seven anopheline species were tested by CSP-ELISA for Plasmodium falciparum and Plasmodium vivax (Pv210 and Pv247). Two new vector species were identified for the region: Anopheles pampanai (P. vivax) and Anopheles barbirostris (Plasmodium malariae). In 88% (155/176) of the mosquitoes found positive with the P. falciparum CSP-ELISA, the presence of Plasmodium sporozoites could not be confirmed by PCR. This percentage was much lower (28% or 5/18) for P. vivax CSP-ELISAs. False positive CSP-ELISA results were associated with zoophilic mosquito species. None of the targeted parasites could be detected in these CSP-ELISA false positive mosquitoes. The ELISA reacting antigen of P. falciparum was heat-stable in CSP-ELISA true positive specimens, but not in the false positives. The heat-unstable cross-reacting antigen is mainly present in head and thorax and almost absent in the abdomens (4 out of 147) of the false positive specimens. Conclusion The CSP-ELISA can considerably overestimate the EIR, particularly for P. falciparum and for zoophilic species. The heat-unstable cross-reacting antigen in false positives remains unknown. Therefore it is highly recommended to confirm all positive CSP-ELISA results, either by re-analysing the heated ELISA lysate (100°C, 10 min), or by performing Plasmodium specific PCR followed if possible by sequencing of the amplicons for Plasmodium species determination. PMID:21767376

  1. The probability of false positives in zero-dimensional analyses of one-dimensional kinematic, force and EMG trajectories.

    PubMed

    Pataky, Todd C; Vanrenterghem, Jos; Robinson, Mark A

    2016-06-14

    A false positive is the mistake of inferring an effect when none exists, and although α controls the false positive (Type I error) rate in classical hypothesis testing, a given α value is accurate only if the underlying model of randomness appropriately reflects experimentally observed variance. Hypotheses pertaining to one-dimensional (1D) (e.g. time-varying) biomechanical trajectories are most often tested using a traditional zero-dimensional (0D) Gaussian model of randomness, but variance in these datasets is clearly 1D. The purpose of this study was to determine the likelihood that analyzing smooth 1D data with a 0D model of variance will produce false positives. We first used random field theory (RFT) to predict the probability of false positives in 0D analyses. We then validated RFT predictions via numerical simulations of smooth Gaussian 1D trajectories. Results showed that, across a range of public kinematic, force/moment and EMG datasets, the median false positive rate was 0.382 and not the assumed α=0.05, even for a simple two-sample t test involving N=10 trajectories per group. The median false positive rate for experiments involving three-component vector trajectories was p=0.764. This rate increased to p=0.945 for two three-component vector trajectories, and to p=0.999 for six three-component vectors. This implies that experiments involving vector trajectories have a high probability of yielding 0D statistical significance when there is, in fact, no 1D effect. Either (a) explicit a priori identification of 0D variables or (b) adoption of 1D methods can more tightly control α. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Factors that influence standard automated perimetry test results in glaucoma: test reliability, technician experience, time of day, and season.

    PubMed

    Junoy Montolio, Francisco G; Wesselink, Christiaan; Gordijn, Marijke; Jansonius, Nomdo M

    2012-10-09

    To determine the influence of several factors on standard automated perimetry test results in glaucoma. Longitudinal Humphrey field analyzer 30-2 Swedish interactive threshold algorithm data from 160 eyes of 160 glaucoma patients were used. The influence of technician experience, time of day, and season on the mean deviation (MD) was determined by performing linear regression analysis of MD against time on a series of visual fields and subsequently performing a multiple linear regression analysis with the MD residuals as dependent variable and the factors mentioned above as independent variables. Analyses were performed with and without adjustment for the test reliability (fixation losses and false-positive and false-negative answers) and with and without stratification according to disease stage (baseline MD). Mean follow-up was 9.4 years, with on average 10.8 tests per patient. Technician experience, time of day, and season were associated with the MD. Approximately 0.2 dB lower MD values were found for inexperienced technicians (P < 0.001), tests performed after lunch (P < 0.001), and tests performed in the summer or autumn (P < 0.001). The effects of time of day and season appeared to depend on disease stage. Independent of these effects, the percentage of false-positive answers strongly influenced the MD with a 1 dB increase in MD per 10% increase in false-positive answers. Technician experience, time of day, season, and the percentage of false-positive answers have a significant influence on the MD of standard automated perimetry.

  3. Screening for subclinical Cushing's syndrome in type 2 diabetes mellitus: low false-positive rates with nocturnal salivary cortisol.

    PubMed

    Gagliardi, L; Chapman, I M; O'Loughlin, P; Torpy, D J

    2010-04-01

    The diagnosis of subclinical Cushing's syndrome (SCS) is important, but its relative rarity amongst patients with common metabolic disorders requires a simple test with a low false-positive rate. Using nocturnal salivary cortisol (NSC), which we first validated in patients with suspected and proven Cushing's syndrome, we screened 106 overweight patients with type 2 diabetes mellitus, a group at high risk of SCS and nontumoral hypothalamic-pituitary-adrenal axis perturbations. Our hypothesis was that a lower false-positive rate with NSC was likely, compared with that reported with the dexamethasone suppression test (DST) (10-20%), currently the foundation of diagnosis of SCS. No participant had clinically apparent Cushing's syndrome. Three participants had an elevated NSC but further testing excluded SCS. In this study, NSC had a lower false-positive rate (3%) than previously reported for the DST. Given the reported excellent performance of NSC in detection of hypercortisolism, the low false-positive rate in SCS suggests NSC may be superior to the DST for SCS screening. The NSC and DST should be compared directly in metabolic disorder patients; although our data suggest the patient group will need to be substantially larger to definitively determine the optimal screening test. Georg Thieme Verlag KG Stuttgart New York.

  4. Tinel's sign or percussion test? Developing a better method of evoking a Tinel's sign.

    PubMed

    Monsivais, J J; Sun, Y

    1997-01-01

    Clinicians elicit a Tinel's sign by tapping over a nerve site with their fingertips. No standard force has been established, and overzealous tapping can produce a false-positive "Tinel's sign" that is actually a positive percussion test. The purpose of our study was to determine a threshold force that produces a positive percussion test in each of seven nerve locations in the upper extremities of subjects with no known nerve injuries and in subjects with nerve injuries. These data suggest limits for the amount of force necessary to elicit a Tinel's sign. If these limits are adhered to, the incidence of false-positive responses may be kept low.

  5. Statistics provide guidance for indigenous organic carbon detection on Mars missions.

    PubMed

    Sephton, Mark A; Carter, Jonathan N

    2014-08-01

    Data from the Viking and Mars Science Laboratory missions indicate the presence of organic compounds that are not definitively martian in origin. Both contamination and confounding mineralogies have been suggested as alternatives to indigenous organic carbon. Intuitive thought suggests that we are repeatedly obtaining data that confirms the same level of uncertainty. Bayesian statistics may suggest otherwise. If an organic detection method has a true positive to false positive ratio greater than one, then repeated organic matter detection progressively increases the probability of indigeneity. Bayesian statistics also reveal that methods with higher ratios of true positives to false positives give higher overall probabilities and that detection of organic matter in a sample with a higher prior probability of indigenous organic carbon produces greater confidence. Bayesian statistics, therefore, provide guidance for the planning and operation of organic carbon detection activities on Mars. Suggestions for future organic carbon detection missions and instruments are as follows: (i) On Earth, instruments should be tested with analog samples of known organic content to determine their true positive to false positive ratios. (ii) On the mission, for an instrument with a true positive to false positive ratio above one, it should be recognized that each positive detection of organic carbon will result in a progressive increase in the probability of indigenous organic carbon being present; repeated measurements, therefore, can overcome some of the deficiencies of a less-than-definitive test. (iii) For a fixed number of analyses, the highest true positive to false positive ratio method or instrument will provide the greatest probability that indigenous organic carbon is present. (iv) On Mars, analyses should concentrate on samples with highest prior probability of indigenous organic carbon; intuitive desires to contrast samples of high prior probability and low prior probability of indigenous organic carbon should be resisted.

  6. Limits of intravascular contrast extravasation on computed tomography scan to define the need for pelvic angioembolization in pelvic blunt trauma: a specific assessment on the risk of false-positives.

    PubMed

    Ramin, Séverin; Hermida, Margaux; Millet, Ingrid; Murez, Thibault; Monnin, Valérie; Hamoui, Mazen; Capdevila, Xavier; Charbit, Jonathan

    2018-06-12

    The objective was to assess the predictive performance of different intravascular contrast extravasation (ICE) characteristics for need for pelvic transarterial embolization (TAE) to determine the risk factors of false-positives. A retrospective study was performed in our trauma center between 2010 and 2015. All severe trauma patients with pelvic fracture were included. Pelvic ICE characteristics on computed tomography (CT) scan were studied: arterial (aSICE), portal surface (pSICE), and extension (exSICE) anatomic relationships. The overall predictive performance of ICE surfaces for pelvic TAE was analyzed using receiver operating characteristic curves. The analysis focused on risk factors for false-positives. Among 311 severe trauma patients with pelvic ring fracture (mean age, 42 ± 19 years, mean Injury Severity Score, 27 ± 19), 94 (30%) had at least one pelvic ICE on the initial CT scan. Patients requiring pelvic TAE had significantly larger aSICE and pSICE than others (P=0.001 and P=0.035, respectively). The overall ability of ICE surfaces to predict pelvic TAE was modest (aSICE AUC, 0.76 [95% CI, 0.64-0.90]; P=0.011) or non-significant (pSICE and exSICE). The high-sensitivity threshold was defined as aSICE ≥20 mm. Using this threshold, 76% of patients were false-positives. Risk factors for false-positives were: admission systolic blood pressure ≥90 mmHg (63% versus 20%; P=0.03) and low transfusion needs (63% versus 10%; P=0.009), extravasation in contact with complex bone fracture (78% versus 30%; P=0.008) or the absence of a direct relationship between extravasation and a large retroperitoneal hematoma (100% versus 38%; P<0.001). A significant pelvic ICE during the arterial phase does not guarantee the need for pelvic TAE. Three-quarter of patients with aSICE ≥20 mm did not need pelvic TAE. Several complementary CT scan criteria will help to identify this risk of false-positives to determine adequate hemostatic pelvic procedures.This work is an original article, retrospective study Level II of evidence, Therapeutic/Critical Care management.

  7. Analyzing false positives of four questions in the Force Concept Inventory

    NASA Astrophysics Data System (ADS)

    Yasuda, Jun-ichiro; Mae, Naohiro; Hull, Michael M.; Taniguchi, Masa-aki

    2018-06-01

    In this study, we analyze the systematic error from false positives of the Force Concept Inventory (FCI). We compare the systematic errors of question 6 (Q.6), Q.7, and Q.16, for which clearly erroneous reasoning has been found, with Q.5, for which clearly erroneous reasoning has not been found. We determine whether or not a correct response to a given FCI question is a false positive using subquestions. In addition to the 30 original questions, subquestions were introduced for Q.5, Q.6, Q.7, and Q.16. This modified version of the FCI was administered to 1145 university students in Japan from 2015 to 2017. In this paper, we discuss our finding that the systematic errors of Q.6, Q.7, and Q.16 are much larger than that of Q.5 for students with mid-level FCI scores. Furthermore, we find that, averaged over the data sample, the sum of the false positives from Q.5, Q.6, Q.7, and Q.16 is about 10% of the FCI score of a midlevel student.

  8. Visual field progression in glaucoma: what is the specificity of the Guided Progression Analysis?

    PubMed

    Artes, Paul H; O'Leary, Neil; Nicolela, Marcelo T; Chauhan, Balwantray C; Crabb, David P

    2014-10-01

    To estimate the specificity of the Guided Progression Analysis (GPA) (Carl Zeiss Meditec, Dublin, CA) in individual patients with glaucoma. Observational cohort study. Thirty patients with open-angle glaucoma. In 30 patients with open-angle glaucoma, 1 eye (median mean deviation [MD], -2.5 decibels [dB]; interquartile range, -4.4 to -1.3 dB) was tested 12 times over 3 months (Humphrey Field Analyzer, Carl Zeiss Meditec; SITA Standard, 24-2). "Possible progression" and "likely progression" were determined with the GPA. These analyses were repeated after the order of the tests had been randomly rearranged (1000 unique permutations). Rate of false-positive alerts of "possible progression" and "likely progression" with the GPA. On average, the specificity of the GPA "likely progression" alert was high-for the entire sample, the mean rate of false-positive alerts after 10 follow-up tests was 2.6%. With "possible progression," the specificity was considerably lower (false-positive rate, 18.5%). Most important, the cumulative rate of false-positive alerts varied substantially among patients, from <1% to 80% with "possible progression" and from <0.1% to 20% with "likely progression." Factors associated with false-positive alerts were visual field variability (standard deviation of MD, Spearman's rho = 0.41, P<0.001) and the reliability indices (proportion of false-positive and false-negative responses, fixation losses, rho>0.31, P≤0.10). On average, progression criteria currently used in the GPA have high specificity, but some patients are more likely to show false-positive alerts than others. This is a natural consequence of population-based change criteria and may not matter in clinical trials and studies in which large groups of patients are compared. However, it must be considered when the GPA is used in clinical practice where specificity needs to be controlled for individual patients. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  9. Mixed group validation: a method to address the limitations of criterion group validation in research on malingering detection.

    PubMed

    Frederick, R I

    2000-01-01

    Mixed group validation (MGV) is offered as an alternative to criterion group validation (CGV) to estimate the true positive and false positive rates of tests and other diagnostic signs. CGV requires perfect confidence about each research participant's status with respect to the presence or absence of pathology. MGV determines diagnostic efficiencies based on group data; knowing an individual's status with respect to pathology is not required. MGV can use relatively weak indicators to validate better diagnostic signs, whereas CGV requires perfect diagnostic signs to avoid error in computing true positive and false positive rates. The process of MGV is explained, and a computer simulation demonstrates the soundness of the procedure. MGV of the Rey 15-Item Memory Test (Rey, 1958) for 723 pre-trial criminal defendants resulted in higher estimates of true positive rates and lower estimates of false positive rates as compared with prior research conducted with CGV. The author demonstrates how MGV addresses all the criticisms Rogers (1997b) outlined for differential prevalence designs in malingering detection research. Copyright 2000 John Wiley & Sons, Ltd.

  10. The incidence and clinical implication of sputum with positive acid-fast bacilli smear but negative in mycobacterial culture in a tertiary referral hospital in South Korea.

    PubMed

    Lee, Jae Seok; Kim, Eui-Chong; Joo, Sei Ick; Lee, Sang-Min; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Shim, Young-Soo; Yim, Jae-Joon

    2008-10-01

    Although it is not rare to find sputum that is positive acid-fast bacilli (AFB) smear but subsequent culture fails to isolate mycobacteria in clinical practice, the incidence and clinical implication of those sputa from new patients has not been clearly elucidated. The aim of this study was to determine the incidence and clinical implication of sputum with positive AFB smear but negative in mycobacterial culture. All sputa that were positive AFB smear requested during diagnostic work up for new patients visiting Seoul National University Hospital from 1 January 2005 through 31 December 2006 were included. Sputa producing a positive AFB smear but negative mycobacterial culture were classified into one of four categories: laboratory failure to isolate mycobacteria, false positive AFB smear, pathogen may show a positive AFB smear other than mycobacteria, and indeterminate results. Out of 447 sputa with a positive AFB smear, 29 (6.5%) failed to culture any organism. Among these 29 sputa, 18 were caused by laboratory failure to isolate mycobacteria, six were false positive smears, and five indeterminate. Although most sputum with a positive AFB smear but negative culture could be classified as a laboratory failure, clinicians should consider the possibility of false positive AFB smear.

  11. 5 CFR 532.263 - Special wage schedules for production facilitating positions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Special wage schedules for production facilitating positions. 532.263 Section 532.263 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PREVAILING RATE SYSTEMS Prevailing Rate Determinations § 532.263 Special wage...

  12. 5 CFR 532.249 - Minimum rates for hard-to-fill positions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Minimum rates for hard-to-fill positions. 532.249 Section 532.249 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PREVAILING RATE SYSTEMS Prevailing Rate Determinations § 532.249 Minimum rates for hard-to-fill...

  13. 5 CFR 532.249 - Minimum rates for hard-to-fill positions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 1 2013-01-01 2013-01-01 false Minimum rates for hard-to-fill positions. 532.249 Section 532.249 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PREVAILING RATE SYSTEMS Prevailing Rate Determinations § 532.249 Minimum rates for hard-to-fill...

  14. 5 CFR 532.249 - Minimum rates for hard-to-fill positions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Minimum rates for hard-to-fill positions. 532.249 Section 532.249 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PREVAILING RATE SYSTEMS Prevailing Rate Determinations § 532.249 Minimum rates for hard-to-fill...

  15. Do mammographic technologists affect radiologists’ diagnostic mammography interpretative performance?

    PubMed Central

    Henderson, Louise M.; Benefield, Thad; Bowling, J. Michael; Durham, Danielle; Marsh, Mary W.; Schroeder, Bruce F.; Yankaskas, Bonnie C.

    2015-01-01

    Objective The purpose of this study was to determine whether the technologist has an effect on the radiologists’ interpretative performance of diagnostic mammography. Materials and Methods Using data from a community based mammography registry from 1994 to 2009, we identified 162,755 diagnostic mammograms interpreted by 286 radiologists and performed by 303 mammographic technologists. We calculated sensitivity, false positive rate, and positive predictive value of biopsy (PPV2) for examinations performed (images taken) by each mammographic technologist, separately for film and digital modalities. We assessed the variability of these performance measures among mammographic technologists, using mixed effects logistic regression and taking into account the clustering of examinations within women, radiologists, and radiology practice. Results Among the 291 technologists performing film examinations, mean sensitivity of the examinations they performed was 83.0% (95% Confidence Interval (CI)=80.8–85.2%), mean false positive rate was 8.5 per 1000 examinations (95%CI: 8.0–9.0%), and mean PPV2 was 27.1% (95%CI: 24.8–29.4). For the 45 technologists performing digital examinations, mean sensitivity of the examinations they performed was 79.6% (95%CI: 73.1–86.2%), mean false positive rate was 8.8 (95%CI: 7.5–10.0%), and mean PPV2 was 23.6% (95%CI: 18.8–28.4%). We found significant variation by technologist in the sensitivity, false positive rate, and PPV2 for film but not digital mammography (p<0.0001 for all 3 film performance measures). Conclusions Our results suggest that the technologist has an influence on radiologists’ performance of diagnostic film mammography but not digital. Future work should examine why this difference by modality exists and determine if similar patterns are observed for screening mammography. PMID:25794085

  16. Phenolphthalein false-positive reactions from legume root nodules.

    PubMed

    Petersen, Daniel; Kovacs, Frank

    2014-03-01

    Presumptive tests for blood play a critical role in the examination of physical evidence and in the determination of subsequent analysis. The catalytic power of hemoglobin allows colorimetric reactions employing phenolphthalein (Kastle-Meyer test) to indicate "whether" blood is present. Consequently, DNA profiles extracted from phenolphthalein-positive stains are presumed to be from blood on the evidentiary item and can lead to the identification of "whose" blood is present. Crushed nodules from a variety of legumes yielded phenolphthalein false-positive reactions that were indistinguishable from true bloodstains both in color quality and in developmental time frame. Clothing and other materials stained by nodules also yielded phenolphthalein false-positive reactivity for several years after nodule exposure. Nodules from leguminous plants contain a protein (leghemoglobin) which is structurally and functionally similar to hemoglobin. Testing of purified leghemoglobin confirmed this protein as a source of phenolphthalein reactivity. A scenario is presented showing how the presence of leghemoglobin from nodule staining can mislead investigators. © 2013 American Academy of Forensic Sciences.

  17. Confirmation of congenital adrenal hyperplasia by adrenal steroid profiling of filter paper dried blood samples using ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Rossi, Claudia; Calton, Lisa; Brown, Heather A; Gillingwater, Scott; Wallace, A Michael; Petrucci, Francesca; Ciavardelli, Domenico; Urbani, Andrea; Sacchetta, Paolo; Morris, Michael

    2011-04-01

    The specificity of screening for congenital adrenal hyperplasia by direct measurement of 17-hydroxyprogesterone in filter paper dried blood spot samples by immunoassay is low and has a high false-positive rate. In order to reduce the false-positive rate of this test, we developed a rapid, robust, specific confirmatory procedure in which cortisol, 4-androstene-3,17-dione and 17-hydroxyprogesterone were measured simultaneously by ultra-performance liquid chromatography-tandem mass spectrometry. After extraction, samples were analysed by ultra-performance liquid chromatography-tandem mass spectrometry and 17-hydroxyprogesterone was quantified accurately. Other steroids were determined using stable deuterated internal standards. In total, 25 patient blood spot samples and 92 control samples were analysed. The assay was linear for 17-hydroxyprogesterone, with a coefficient of determination >0.997 and imprecision ≤ 6.5%. An upper limit of normal for 17-hydroxyprogester-one of 4.45 nmol/L was established by analysing a cohort of samples from unaffected newborns. In addition, a cut-off of 3.5 for the peak areas ratio (17-hydroxyprogesterone+4-androstene-3,17-dione)/cortisol, allows confirmation of the affected steroidogenic enzyme. A high throughput method for the detection of steroids related to congenital adrenal hyperplasia has been developed, allowing the false-positive rate associated with screening for 17-hydroxyprogesterone by immunoassay to be determined.

  18. Case report of a false positive result of the Xpert® MTB/RIF assay for rifampicin resistance in Mycobacterium tuberculosis complex.

    PubMed

    Claessens, Jolien; Mathys, Vanessa; Derdelinckx, Inge; Saegeman, Veroniek

    2017-06-01

    In the present case, we report a false positive result for the detection of rifampicin (RIF) resistance by the Xpert ® MTB/RIF assay, version G4.Miliary Mycobacterium tuberculosis infection (miliary TB) was suspected in a 50-year old Angolan woman. Imaging of the thorax and abdomen displayed diffuse lesions. The Xpert ® MTB/RIF assay conducted on the broncho-alveolar lavage (BAL) fluid was positive for TB and positive for RIF resistance. Confirmatory molecular tests and the phenotypic drug susceptibility determination supported the diagnosis of TB but not RIF resistance. The patient was treated successfully with a conventional therapeutic scheme. Because, the Xpert ® MTB/RIF assay allows the simultaneous detection of TB and RIF resistance, the World Health Organisation (WHO) recommends its use as initial diagnostic test, over microscopy, culture and phenotypic drug susceptibility testing. Even though specificity of the Xpert ® MTB/RIF assay version G4 is high, false positive test results remain possible and have to be considered for the interpretation of the RIF resistance detection by Xpert ® MTB/RIF assay.

  19. Diagnostic value and cost utility analysis for urine Gram stain and urine microscopic examination as screening tests for urinary tract infection.

    PubMed

    Wiwanitkit, Viroj; Udomsantisuk, Nibhond; Boonchalermvichian, Chaiyaporn

    2005-06-01

    The aim of this study was to evaluate the diagnostic properties of urine Gram stain and urine microscopic examination for screening for urinary tract infection (UTI), and to perform an additional cost utility analysis. This descriptive study was performed on 95 urine samples sent for urine culture to the Department of Microbiology, Faculty of Medicine, Chulalongkorn University. The first part of the study was to determine the diagnostic properties of two screening tests (urine Gram stain and urine microscopic examination). Urine culture was set as the gold standard and the results from both methods were compared to this. The second part of this study was to perform a cost utility analysis. The sensitivity of urine Gram stain was 96.2%, the specificity 93.0%, the positive predictive value 94.3% and the negative predictive value 95.2%. False positives occurred with a frequency of 7.0% and false negatives 3.8%. For the microscopic examination, the sensitivity was 65.4%, specificity 74.4%, positive predictive value 75.6% and negative predictive value 64.0%. False positives occurred with a frequency of 25.6% and false negatives 34.6%. Combining urine Gram stain and urine microscopic examination, the sensitivity was 98.1%, specificity 74.4%, positive predictive value 82.3% and negative predictive value 97.0%. False positives occurred with a frequency of 25.6% and false negatives 1.9%. However, the cost per utility of the combined method was higher than either urine microscopic examination or urine Gram stain alone. Urine Gram stain provided the lowest cost per utility. Economically, urine Gram stain is the proper screening tool for presumptive diagnosis of UTI.

  20. Placing symptoms in context: the role of contextual criteria in reducing false positives in Diagnostic and Statistical Manual of Mental Disorders diagnoses.

    PubMed

    Wakefield, Jerome C; First, Michael B

    2012-02-01

    The Diagnostic and Statistical Manual of Mental Disorders (DSM) definition of mental disorder requires that symptoms be caused by a dysfunction in the individual; when dysfunction is absent, symptoms represent normal-range distress or eccentricity and, if diagnosed as a mental disorder, are false positives. We hypothesized that because of psychiatry's lack of direct laboratory tests to distinguish dysfunction from normal-range distress, the context in which symptoms occur (eg, lack of imminent danger in a panic attack) is often essential to determining whether symptoms are caused by a dysfunction. If this is right, then the DSM diagnostic criteria should include many contextual criteria added to symptom syndromes to prevent dysfunction false positives. Despite their potential importance, such contextual criteria have not been previously reviewed. We, thus, systematically reviewed DSM categories to establish the extent of such uses of contextual criteria and created a typology of such uses. Of 111 sampled categories, 68 (61%) used context to prevent dysfunction false positives. Contextual criteria fell into 7 types: (1) exclusion of specific false-positive scenarios; (2) requiring that patients experience preconditions for normal responses (eg, requiring that individuals experience adequate sexual stimulation before being diagnosed with sexual dysfunctions); (3) requiring that symptoms be disproportionate relative to circumstances; (4) for childhood disorders, requiring that symptoms be developmentally inappropriate; (5) requiring that symptoms occur in multiple contexts; (6) requiring a substantial discrepancy between beliefs and reality; and (7) a residual category. Most DSM categories include contextual criteria to eliminate false-positive diagnoses and increase validity of descriptive criteria. Future revisions should systematically evaluate each category's need for contextual criteria. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Determining Occurrence Dynamics when False Positives Occur: Estimating the Range Dynamics of Wolves from Public Survey Data.

    PubMed

    Miller, David A W; Nichols, James D; Gude, Justin A; Rich, Lindsey N; Podruzny, Kevin M; Hines, James E; Mitchell, Michael S

    2013-01-01

    Large-scale presence-absence monitoring programs have great promise for many conservation applications. Their value can be limited by potential incorrect inferences owing to observational errors, especially when data are collected by the public. To combat this, previous analytical methods have focused on addressing non-detection from public survey data. Misclassification errors have received less attention but are also likely to be a common component of public surveys, as well as many other data types. We derive estimators for dynamic occupancy parameters (extinction and colonization), focusing on the case where certainty can be assumed for a subset of detections. We demonstrate how to simultaneously account for non-detection (false negatives) and misclassification (false positives) when estimating occurrence parameters for gray wolves in northern Montana from 2007-2010. Our primary data source for the analysis was observations by deer and elk hunters, reported as part of the state's annual hunter survey. This data was supplemented with data from known locations of radio-collared wolves. We found that occupancy was relatively stable during the years of the study and wolves were largely restricted to the highest quality habitats in the study area. Transitions in the occupancy status of sites were rare, as occupied sites almost always remained occupied and unoccupied sites remained unoccupied. Failing to account for false positives led to over estimation of both the area inhabited by wolves and the frequency of turnover. The ability to properly account for both false negatives and false positives is an important step to improve inferences for conservation from large-scale public surveys. The approach we propose will improve our understanding of the status of wolf populations and is relevant to many other data types where false positives are a component of observations.

  2. Technetium-99m stannous pyrophosphate myocardial scintigraphy after cardiopulmonary resuscitation with cardioversion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davison, R.; Spies, S.M.; Przybylek, J.

    1979-08-01

    Thirty consecutive patients underwent technetium-99m stannous pyrophosphate myocardial scintigraphy 48 to 72 h after successful cardiopulmonary resuscitation and direct current cardioversion. Five patients with transmural myocardial infarctions by ECG and enzyme determinations were correctly identified by scintigraphy. Myocardial scans were positive in five of nine patients with nontransmural infarction. Of 16 patients without evidence of myocardial infarction, only two (13%) had false-positive myocardial scans. The overall accuracy of imaging in this series was 80%. We conclude that false-positive scans after cardiopulmonary resuscitation with electrical cardioversion are infrequent, and do not significantly detract from the value of myocardial scintigraphy in themore » diagnosis of myocardial infarction.« less

  3. Age-standardisation when target setting and auditing performance of Down syndrome screening programmes.

    PubMed

    Cuckle, Howard; Aitken, David; Goodburn, Sandra; Senior, Brian; Spencer, Kevin; Standing, Sue

    2004-11-01

    To describe and illustrate a method of setting Down syndrome screening targets and auditing performance that allows for differences in the maternal age distribution. A reference population was determined from a Gaussian model of maternal age. Target detection and false-positive rates were determined by standard statistical modelling techniques, except that the reference population rather than an observed population was used. Second-trimester marker parameters were obtained for Down syndrome from a large meta-analysis, and for unaffected pregnancies from the combined results of more than 600,000 screens in five centres. Audited detection and false-positive rates were the weighted average of the rates in five broad age groups corrected for viability bias. Weights were based on the age distributions in the reference population. Maternal age was found to approximate reasonably well to a Gaussian distribution with mean 27 years and standard deviation 5.5 years. Depending on marker combination, the target detection rates were 59 to 64% and false-positive rate 4.2 to 5.4% for a 1 in 250 term cut-off; 65 to 68% and 6.1 to 7.3% for 1 in 270 at mid-trimester. Among the five centres, the audited detection rate ranged from 7% below target to 10% above target, with audited false-positive rates better than the target by 0.3 to 1.5%. Age-standardisation should help to improve screening quality by allowing for intrinsic differences between programmes, so that valid comparisons can be made. Copyright 2004 John Wiley & Sons, Ltd.

  4. Application of Reverse Transcriptase -PCR (RT-PCR) for rapid detection of viable Escherichia coli in drinking water samples.

    PubMed

    Molaee, Neda; Abtahi, Hamid; Ghannadzadeh, Mohammad Javad; Karimi, Masoude; Ghaznavi-Rad, Ehsanollah

    2015-01-01

    Polymerase chain reaction (PCR) is preferred to other methods for detecting Escherichia coli (E. coli) in water in terms of speed, accuracy and efficiency. False positive result is considered as the major disadvantages of PCR. For this reason, reverse transcriptase-polymerase chain reaction (RT-PCR) can be used to solve this problem. The aim of present study was to determine the efficiency of RT-PCR for rapid detection of viable Escherichia coli in drinking water samples and enhance its sensitivity through application of different filter membranes. Specific primers were designed for 16S rRNA and elongation Factor II genes. Different concentrations of bacteria were passed through FHLP and HAWP filters. Then, RT-PCR was performed using 16srRNA and EF -Tu primers. Contamination of 10 wells was determined by RT-PCR in Arak city. To evaluate RT-PCR efficiency, the results were compared with most probable number (MPN) method. RT-PCR is able to detect bacteria in different concentrations. Application of EF II primers reduced false positive results compared to 16S rRNA primers. The FHLP hydrophobic filters have higher ability to absorb bacteria compared with HAWB hydrophilic filters. So the use of hydrophobic filters will increase the sensitivity of RT-PCR. RT-PCR shows a higher sensitivity compared to conventional water contamination detection method. Unlike PCR, RT-PCR does not lead to false positive results. The use of EF-Tu primers can reduce the incidence of false positive results. Furthermore, hydrophobic filters have a higher ability to absorb bacteria compared to hydrophilic filters.

  5. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    PubMed

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false negative results due to seroconversion or misclassification by the lower sensitivity dilution test. Further research is needed to determine if these results can be replicated in other settings. ClinicalTrials.gov, NCT01716299 .

  6. 5 CFR 532.273 - Special wage schedules for United States Information Agency Radio Antenna Rigger positions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Special wage schedules for United States Information Agency Radio Antenna Rigger positions. 532.273 Section 532.273 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PREVAILING RATE SYSTEMS Prevailing Rate Determinations § 532...

  7. The Influence of Feedback of Diagnosis and Executive Function Skills on Rates of False Positive and False Negative Outcomes for ADHD

    ERIC Educational Resources Information Center

    Bender, Stacy L.; Privitera, Gregory J.

    2016-01-01

    This study examined executive function (EF) skills and self-reported symptoms of ADHD. EF skills were measured to determine whether skills were different between groups that reported clinical levels of ADHD symptoms (clinical group) and nonclinical levels of ADHD symptoms (nonclinical group). EF skills in the nonclinical group were also…

  8. Quality control in the diagnosis of Trichuris trichiura and Ascaris lumbricoides using the Kato-Katz technique: experience from three randomised controlled trials.

    PubMed

    Speich, Benjamin; Ali, Said M; Ame, Shaali M; Albonico, Marco; Utzinger, Jürg; Keiser, Jennifer

    2015-02-05

    An accurate diagnosis of soil-transmitted helminthiasis is important for individual patient management, for drug efficacy evaluation and for monitoring control programmes. The Kato-Katz technique is the most widely used method detecting soil-transmitted helminth eggs in faecal samples. However, detailed analyses of quality control, including false-positive and faecal egg count (FEC) estimates, have received little attention. Over a 3-year period, within the frame of a series of randomised controlled trials conducted in Pemba, United Republic of Tanzania, 10% of randomly selected Kato-Katz thick smears were re-read for Trichuris trichiura and Ascaris lumbricoides eggs. In case of discordant result (i.e. positive versus negative) the slides were re-examined a third time. A result was assumed to be false-positive or false-negative if the result from the initial reading did not agree with the quality control as well as the third reading. We also evaluated the general agreement in FECs between the first and second reading, according to internal and World Health Organization (WHO) guidelines. From the 1,445 Kato-Katz thick smears subjected to quality control, 1,181 (81.7%) were positive for T. trichiura and 290 (20.1%) were positive for A. lumbricoides. During quality control, very low rates of false-positive results were observed; 0.35% (n = 5) for T. trichiura and 0.28% (n = 4) for A. lumbricoides. False-negative readings of Kato-Katz thick smears were obtained in 28 (1.94%) and 6 (0.42%) instances for T. trichiura and A. lumbricoides, respectively. A high frequency of discordant results in FECs was observed (i.e. 10.0-23.9% for T. trichiura, and 9.0-11.4% for A. lumbricoides). Our analyses show that the rate of false-positive diagnoses of soil-transmitted helminths is low. As the probability of false-positive results increases after examination of multiple stool samples from a single individual, the potential influence of false-positive results on epidemiological studies and anthelminthic drug efficacy studies should be determined. Existing WHO guidelines for quality control might be overambitious and might have to be revised, specifically with regard to handling disagreements in FECs.

  9. Laxative-free CT colonography.

    PubMed

    Slater, A; Betts, M; D'Costa, H

    2012-08-01

    The aim of this study was to determine if the introduction of faecal tagging to CT colonography (CTC) made the examination easier to tolerate or reduced the number of false-positives. Our department changed bowel preparation for CT colonography from Picolax (Ferring Pharmaceuticals Ltd, London, UK) to Gastrografin (Bracco Diagnostics Inc, Princeton, NJ) only with a modified diet. Questionnaires were given to a subgroup of patients within these cohorts. The numbers of false-positives were compared between two cohorts before and after this change. false-positives were defined as lesions reported on CT that were not confirmed by subsequent endoscopic examination. Polyps were matched if they were in the same or adjacent segments, and were within 5 mm of the reported size. 412 patients were identified from the Picolax cohort, and 116 from the Gastrografin cohort. 62 patients in each group completed questionnaires. Gastrografin produced less diarrhoea; 34% had five or more bowel motions in the previous day and night, compared with 77% for Picolax (p<0.001), although more patients found drinking it unpleasant compared with Picolax (85% reported drinking Picolax as "easy" vs 61% for Gastrografin; p=0.002). Picolax produced more non-diagnostic examinations, although this difference was not statistically significant. There was not a significant reduction in the numbers of false-positives (2 out of 112 for Gastrografin group, 14 out of 389 for the Picolax group; p=0.54). Switching from Picolax to Gastrografin as a CTC preparation technique produced less diarrhoea, but did not reduce the number of false-positives.

  10. Misdiagnosis of HIV infection during a South African community-based survey: implications for rapid HIV testing

    PubMed Central

    Kufa, Tendesayi; Kharsany, Ayesha BM; Cawood, Cherie; Khanyile, David; Lewis, Lara; Grobler, Anneke; Chipeta, Zawadi; Bere, Alfred; Glenshaw, Mary; Puren, Adrian

    2017-01-01

    Abstract Introduction: We describe the overall accuracy and performance of a serial rapid HIV testing algorithm used in community-based HIV testing in the context of a population-based household survey conducted in two sub-districts of uMgungundlovu district, KwaZulu-Natal, South Africa, against reference fourth-generation HIV-1/2 antibody and p24 antigen combination immunoassays. We discuss implications of the findings on rapid HIV testing programmes. Methods: Cross-sectional design: Following enrolment into the survey, questionnaires were administered to eligible and consenting participants in order to obtain demographic and HIV-related data. Peripheral blood samples were collected for HIV-related testing. Participants were offered community-based HIV testing in the home by trained field workers using a serial algorithm with two rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using two fourth-generation immunoassays with all positives in the confirmatory test considered true positives. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value and false-positive and false-negative rates were determined. Results: Of 10,236 individuals enrolled in the survey, 3740 were tested in the home (median age 24 years (interquartile range 19–31 years), 42.1% males and HIV positivity on RDT algorithm 8.0%). From those tested, 3729 (99.7%) had a definitive RDT result as well as a laboratory immunoassay result. The overall accuracy of the RDT when compared to the fourth-generation immunoassays was 98.8% (95% confidence interval (CI) 98.5–99.2). The sensitivity, specificity, positive predictive value and negative predictive value were 91.1% (95% CI 87.5–93.7), 99.9% (95% CI 99.8–100), 99.3% (95% CI 97.4–99.8) and 99.1% (95% CI 98.8–99.4) respectively. The false-positive and false-negative rates were 0.06% (95% CI 0.01–0.24) and 8.9% (95% CI 6.3–12.53). Compared to true positives, false negatives were more likely to be recently infected on limited antigen avidity assay and to report antiretroviral therapy (ART) use. Conclusions: The overall accuracy of the RDT algorithm was high. However, there were few false positives, and the sensitivity was lower than expected with high false negatives, despite implementation of quality assurance measures. False negatives were associated with recent (early) infection and ART exposure. The RDT algorithm was able to correctly identify the majority of HIV infections in community-based HIV testing. Messaging on the potential for false positives and false negatives should be included in these programmes. PMID:28872274

  11. The semantics of emotion in false memory.

    PubMed

    Brainerd, C J; Bookbinder, S H

    2018-03-26

    The emotional valence of target information has been a centerpiece of recent false memory research, but in most experiments, it has been confounded with emotional arousal. We sought to clarify the results of such research by identifying a shared mathematical relation between valence and arousal ratings in commonly administered normed materials. That relation was then used to (a) decide whether arousal as well as valence influences false memory when they are confounded and to (b) determine whether semantic properties that are known to affect false memory covary with valence and arousal ratings. In Study 1, we identified a quadratic relation between valence and arousal ratings of words and pictures that has 2 key properties: Arousal increases more rapidly as function of negative valence than positive valence, and hence, a given level of negative valence is more arousing than the same level of positive valence. This quadratic function predicts that if arousal as well as valence affects false memory when they are confounded, false memory data must have certain fine-grained properties. In Study 2, those properties were absent from norming data for the Cornell-Cortland Emotional Word Lists, indicating that valence but not arousal affects false memory in those norms. In Study 3, we tested fuzzy-trace theory's explanation of that pattern: that valence ratings are positively related to semantic properties that are known to increase false memory, but arousal ratings are not. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  12. A novel gamma-fitting statistical method for anti-drug antibody assays to establish assay cut points for data with non-normal distribution.

    PubMed

    Schlain, Brian; Amaravadi, Lakshmi; Donley, Jean; Wickramasekera, Ananda; Bennett, Donald; Subramanyam, Meena

    2010-01-31

    In recent years there has been growing recognition of the impact of anti-drug or anti-therapeutic antibodies (ADAs, ATAs) on the pharmacokinetic and pharmacodynamic behavior of the drug, which ultimately affects drug exposure and activity. These anti-drug antibodies can also impact safety of the therapeutic by inducing a range of reactions from hypersensitivity to neutralization of the activity of an endogenous protein. Assessments of immunogenicity, therefore, are critically dependent on the bioanalytical method used to test samples, in which a positive versus negative reactivity is determined by a statistically derived cut point based on the distribution of drug naïve samples. For non-normally distributed data, a novel gamma-fitting method for obtaining assay cut points is presented. Non-normal immunogenicity data distributions, which tend to be unimodal and positively skewed, can often be modeled by 3-parameter gamma fits. Under a gamma regime, gamma based cut points were found to be more accurate (closer to their targeted false positive rates) compared to normal or log-normal methods and more precise (smaller standard errors of cut point estimators) compared with the nonparametric percentile method. Under a gamma regime, normal theory based methods for estimating cut points targeting a 5% false positive rate were found in computer simulation experiments to have, on average, false positive rates ranging from 6.2 to 8.3% (or positive biases between +1.2 and +3.3%) with bias decreasing with the magnitude of the gamma shape parameter. The log-normal fits tended, on average, to underestimate false positive rates with negative biases as large a -2.3% with absolute bias decreasing with the shape parameter. These results were consistent with the well known fact that gamma distributions become less skewed and closer to a normal distribution as their shape parameters increase. Inflated false positive rates, especially in a screening assay, shifts the emphasis to confirm test results in a subsequent test (confirmatory assay). On the other hand, deflated false positive rates in the case of screening immunogenicity assays will not meet the minimum 5% false positive target as proposed in the immunogenicity assay guidance white papers. Copyright 2009 Elsevier B.V. All rights reserved.

  13. The efficacy of protoporphyrin as a predictive biomarker for lead exposure in canvasback ducks: effect of sample storage time

    USGS Publications Warehouse

    Franson, J.C.; Hohman, W.L.; Moore, J.L.; Smith, M.R.

    1996-01-01

    We used 363 blood samples collected from wild canvasback dueks (Aythya valisineria) at Catahoula Lake, Louisiana, U.S.A. to evaluate the effect of sample storage time on the efficacy of erythrocytic protoporphyrin as an indicator of lead exposure. The protoporphyrin concentration of each sample was determined by hematofluorometry within 5 min of blood collection and after refrigeration at 4 °C for 24 and 48 h. All samples were analyzed for lead by atomic absorption spectrophotometry. Based on a blood lead concentration of ≥0.2 ppm wet weight as positive evidence for lead exposure, the protoporphyrin technique resulted in overall error rates of 29%, 20%, and 19% and false negative error rates of 47%, 29% and 25% when hematofluorometric determinations were made on blood at 5 min, 24 h, and 48 h, respectively. False positive error rates were less than 10% for all three measurement times. The accuracy of the 24-h erythrocytic protoporphyrin classification of blood samples as positive or negative for lead exposure was significantly greater than the 5-min classification, but no improvement in accuracy was gained when samples were tested at 48 h. The false negative errors were probably due, at least in part, to the lag time between lead exposure and the increase of blood protoporphyrin concentrations. False negatives resulted in an underestimation of the true number of canvasbacks exposed to lead, indicating that hematofluorometry provides a conservative estimate of lead exposure.

  14. Diagnostic classification of macular ganglion cell and retinal nerve fiber layer analysis: differentiation of false-positives from glaucoma.

    PubMed

    Kim, Ko Eun; Jeoung, Jin Wook; Park, Ki Ho; Kim, Dong Myung; Kim, Seok Hwan

    2015-03-01

    To investigate the rate and associated factors of false-positive diagnostic classification of ganglion cell analysis (GCA) and retinal nerve fiber layer (RNFL) maps, and characteristic false-positive patterns on optical coherence tomography (OCT) deviation maps. Prospective, cross-sectional study. A total of 104 healthy eyes of 104 normal participants. All participants underwent peripapillary and macular spectral-domain (Cirrus-HD, Carl Zeiss Meditec Inc, Dublin, CA) OCT scans. False-positive diagnostic classification was defined as yellow or red color-coded areas for GCA and RNFL maps. Univariate and multivariate logistic regression analyses were used to determine associated factors. Eyes with abnormal OCT deviation maps were categorized on the basis of the shape and location of abnormal color-coded area. Differences in clinical characteristics among the subgroups were compared. (1) The rate and associated factors of false-positive OCT maps; (2) patterns of false-positive, color-coded areas on the GCA deviation map and associated clinical characteristics. Of the 104 healthy eyes, 42 (40.4%) and 32 (30.8%) showed abnormal diagnostic classifications on any of the GCA and RNFL maps, respectively. Multivariate analysis revealed that false-positive GCA diagnostic classification was associated with longer axial length and larger fovea-disc angle, whereas longer axial length and smaller disc area were associated with abnormal RNFL maps. Eyes with abnormal GCA deviation map were categorized as group A (donut-shaped round area around the inner annulus), group B (island-like isolated area), and group C (diffuse, circular area with an irregular inner margin in either). The axial length showed a significant increasing trend from group A to C (P=0.001), and likewise, the refractive error was more myopic in group C than in groups A (P=0.015) and B (P=0.014). Group C had thinner average ganglion cell-inner plexiform layer thickness compared with other groups (group A=B>C, P=0.004). Abnormal OCT diagnostic classification should be interpreted with caution, especially in eyes with long axial lengths, large fovea-disc angles, and small optic discs. Our findings suggest that the characteristic patterns of OCT deviation map can provide useful clues to distinguish glaucomatous changes from false-positive findings. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  15. The accuracy of HIV rapid testing in integrated bio-behavioral surveys of men who have sex with men across 5 Provinces in South Africa

    PubMed Central

    Kufa, Tendesayi; Lane, Tim; Manyuchi, Albert; Singh, Beverley; Isdahl, Zachary; Osmand, Thomas; Grasso, Mike; Struthers, Helen; McIntyre, James; Chipeta, Zawadi; Puren, Adrian

    2017-01-01

    Abstract We describe the accuracy of serial rapid HIV testing among men who have sex with men (MSM) in South Africa and discuss the implications for HIV testing and prevention. This was a cross-sectional survey conducted at five stand-alone facilities from five provinces. Demographic, behavioral, and clinical data were collected. Dried blood spots were obtained for HIV-related testing. Participants were offered rapid HIV testing using 2 rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using a third-generation enzyme immunoassay (EIA) and a fourth-generation EIA as confirmatory. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value, false-positive, and false-negative rates were determined. Between August 2015 and July 2016, 2503 participants were enrolled. Of these, 2343 were tested by RDT on site with a further 2137 (91.2%) having definitive results on both RDT and EIA. Sensitivity, specificity, positive predictive value, negative predictive value, false-positive rates, and false-negative rates were 92.6% [95% confidence interval (95% CI) 89.6–94.8], 99.4% (95% CI 98.9–99.7), 97.4% (95% CI 95.2–98.6), 98.3% (95% CI 97.6–98.8), 0.6% (95% CI 0.3–1.1), and 7.4% (95% CI 5.2–10.4), respectively. False negatives were similar to true positives with respect to virological profiles. Overall accuracy of the RDT algorithm was high, but sensitivity was lower than expected. Post-HIV test counseling should include discussions of possible false-negative results and the need for retesting among HIV negatives. PMID:28700474

  16. Can imaging criteria distinguish enchondroma from grade 1 chondrosarcoma?

    PubMed

    Crim, Julia; Schmidt, Robert; Layfield, Lester; Hanrahan, Christopher; Manaster, Betty Jean

    2015-11-01

    To minimize systematic bias and optimize agreement on imaging criteria in order to better define the accuracy of imaging criteria in the diagnosis of grade 1 chondrosarcoma. Study was IRB-approved and HIPAA compliant; informed consent was waived. Records were reviewed and disclosed 53 cases (38 women, 15 men ages 21-76) which were diagnosed as enchondroma or grade 1 chondrosarcoma and had available radiographs, contrast-enhanced MRI, and definitive diagnosis by histology or 5-year follow-up. 2 MSK radiologists read the studies independently after a session where they agreed on criteria for malignancy. Interobserver variability was determined as raw variability and with the kappa statistic. Accuracy was determined compared to final diagnosis. Reliability of imaging features of chondrosarcoma was determined using regression analysis. The correct diagnosis of enchondroma was made on radiographs in 43 (67.2%) of readings, and on MRI in 37/64 (57.8%). The correct diagnosis of chondrosarcoma was made on radiographs in 5/24 (20.8%) of readings, and on MRI in 14/24 (57.8%). A diagnosis of borderline lesion was made in 19/64 (29.7%) of enchondromas on radiographs and 18/64 (28.1%) on MRI. The false positive rate of radiographs for chondrosarcoma was 2/64 (3.1%) and the false positive rate of MRI was 9/64 (14.1%). There was substantial interobserver variability. Cortical thickening and bone expansion were rare but specific signs of chondrosarcoma. Both radiographs and MRI have limitations in the evaluation of low-grade cartilage lesions. MRI has an increased rate of both true-positive and false-positive diagnosis compared to radiographs. Differences in the findings of this study compared to previous literature may reflect the influence of systematic biases. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. First European interlaboratory comparison of tetracycline and age determination with red fox teeth following oral rabies vaccination programs.

    PubMed

    Robardet, Emmanuelle; Demerson, Jean-Michel; Andrieu, Sabrina; Cliquet, Florence

    2012-10-01

    The first European interlaboratory comparison of tetracycline and age determination with red fox (Vulpes vulpes) tooth samples was organized by the European Union Reference Laboratory for rabies. Performance and procedures implemented by member states were compared. These techniques are widely used to monitor bait uptake in European oral rabies vaccination campaigns. A panel of five red fox half-mandibles comprising one weak positive juvenile sample, two positive adult samples, one negative juvenile sample, and one negative adult sample were sent, along with a technical questionnaire, to 12 laboratories participating on a voluntary basis. The results of only three laboratories (25%) were 100% correct. False-negative results were more frequently seen in weak positive juvenile samples (58%) but were infrequent in positive adult samples (4%), probably due to differences in the ease of reading the two groups of teeth. Four laboratories (44%) had correct results for age determination on all samples. Ages were incorrectly identified in both adult and juvenile samples, with 11 and 17% of discordant results, respectively. Analysis of the technical questionnaires in parallel with test results suggested that all laboratories cutting mandible sections between the canine and first premolar obtained false results. All the laboratories using longitudinal rather than transverse sections and those not using a mounting medium also produced false results. Section thickness appeared to affect the results; no mistakes were found in laboratories using sections <150 μm thick. Factors having a potential impact on the success of laboratories were discussed, and recommendations proposed. Such interlaboratory trials underline the importance of using standardized procedures for biomarker detection in oral rabies vaccination campaigns. Several changes can be made to improve analysis quality and increase the comparability of bait uptake frequencies among member states.

  18. Comparison of a novel chemiluminescence enzyme immunoassay (CLEIA) with enzyme-linked immunosorbent assay (ELISA) for the determination of MPO-ANCA in patients with ANCA-associated vasculitis.

    PubMed

    Hirose, Orie; Itabashi, Mitsuyo; Takei, Takashi; Nitta, Kosaku

    2015-03-01

    Myeloperoxidase (MPO) anti-neutrophil cytoplasmic antibody (ANCA) represents the serological hallmark of ANCA-associated vasculitis (AAV). We evaluated the analytical and diagnostic accuracy of chemiluminescence enzyme immunoassay (CLEIA) versus enzyme-linked immunosorbent assay (ELISA) for the detection of MPO-ANCA. A total of 242 sera obtained from 51 patients with AAV and 103 patients without AAV were tested for MPO-ANCA by ELISA (NephroScholor MPOANC II) and CLEIA (the STACIA MEBLux test). Disease activity in the patients with AAV was determined based on the Birmingham Vasculitis Activity Score. We analyzed the correlations between the MPO-ANCA titers determined by the CLEIA and those determined by the ELISA, and also between the MPO-ANCA titers and the disease activity. The MPO-ANCA titers determined by the CLEIA (x) were strongly correlated with those determined by the ELISA (y). The correlation could be expressed by the following equation in this study: y = 1.8x + 7.7 (r = 0.96; p < 0.0001). At the cutoff value of 3.5 U/ml, the CLEIA yielded positive test results for MPO-ANCA in 73 of the 242 sera (30.2%), while at the cutoff value of 20 U/ml, ELISA yielded positive test results in 57 of the 242 sera (23.6%). The CLEIA yielded false-positive test results in 4 of the 120 sera obtained from the non-AAV patients (3.3%), whereas the ELISA yielded a false-positive result in only 1 of the 120 sera obtained from the non-AAV patients (0.8%). The sensitivity and specificity of the CLEIA for the diagnosis of AAV were 100% and 96.7%, respectively, while those of the ELISA were 94.3% and 99.2%, respectively. The sensitivity and specificity of the CLEIA for the prediction of active disease were 100% and 64.4%, respectively, while those of the ELISA were 94.3% and 73.6%, respectively. The false positivity rate of the CLEIA for MPO-ANCA tended to be high as compared with that of the ELISA. Also, according to the correlation coefficient between the results of the CLEIA and the ELISA calculated in this study, it is necessary to pay attention to the differences in the sensitivity and specificity between CLEIA and ELISA.

  19. Utility of galactomannan antigen detection in bronchoalveolar lavage fluid in immunocompromised patients.

    PubMed

    Brownback, Kyle R; Pitts, Lucas R; Simpson, Steven Q

    2013-09-01

    Diagnosis of invasive pulmonary aspergillosis (IPA) is a challenging process in immunocompromised patients. Galactomannan (GM) antigen detection in bronchoalveolar lavage (BAL) fluid is a method to detect IPA with improved sensitivity over conventional studies. We sought to determine the diagnostic yield of BAL GM assay in a diverse population of immunocompromised patients. A retrospective review of 150 fiberoptic bronchoscopy (FOB) with BAL for newly diagnosed pulmonary infiltrate in immunocompromised patients was performed. Patient information, procedural details and laboratory studies were collected. BAL and serum samples were evaluated for GM using enzyme-linked immunoassay. Of 150 separate FOB with BAL, BAL GM was obtained in 143 samples. There were 31 positive BAL GM assays. In those 31 positive tests, 13 were confirmed as IPA, giving a positive predictive value of 41.9%. There was one false negative BAL GM. Of the 18 false positive BAL GM, 4 were receiving piperacillin-tazobactam and 11 were receiving an alternative beta-lactam antibiotic. BAL GM assay shows excellent sensitivity for diagnosing IPA. There was a significant number of false positive BAL GM assays and several of those patients were receiving beta-lactam antibiotics at the time of bronchoscopy. © 2013 Blackwell Verlag GmbH.

  20. Occupational exposure assessment of magnetic fields generated by induction heating equipment-the role of spatial averaging.

    PubMed

    Kos, Bor; Valič, Blaž; Kotnik, Tadej; Gajšek, Peter

    2012-10-07

    Induction heating equipment is a source of strong and nonhomogeneous magnetic fields, which can exceed occupational reference levels. We investigated a case of an induction tempering tunnel furnace. Measurements of the emitted magnetic flux density (B) were performed during its operation and used to validate a numerical model of the furnace. This model was used to compute the values of B and the induced in situ electric field (E) for 15 different body positions relative to the source. For each body position, the computed B values were used to determine their maximum and average values, using six spatial averaging schemes (9-285 averaging points) and two averaging algorithms (arithmetic mean and quadratic mean). Maximum and average B values were compared to the ICNIRP reference level, and E values to the ICNIRP basic restriction. Our results show that in nonhomogeneous fields, the maximum B is an overly conservative predictor of overexposure, as it yields many false positives. The average B yielded fewer false positives, but as the number of averaging points increased, false negatives emerged. The most reliable averaging schemes were obtained for averaging over the torso with quadratic averaging, with no false negatives even for the maximum number of averaging points investigated.

  1. Six years' experience of using the BacT/ALERT system to screen all platelet concentrates, and additional testing of outdated platelet concentrates to estimate the frequency of false-negative results.

    PubMed

    Larsen, C P; Ezligini, F; Hermansen, N O; Kjeldsen-Kragh, J

    2005-02-01

    Approximately 1 in every 2000 units of platelets is contaminated with bacteria. The BacT/ALERT automated blood culture system can be used to screen platelet concentrates (PCs) for bacterial contamination. Data were collected from May 1998 until May 2004. The number of PCs tested during this period was 36 896, most of which were produced from pools of four buffy-coats. On the day following blood collection or platelet apheresis, a 5-10 ml sample of the PC was aseptically transferred to a BacT/ALERT culture bottle for detection of aerobic bacteria. The sample was monitored for bacterial growth during the entire storage period of the PC (6.5 days). When a positive signal was generated, the culture bottle, the PC and the erythrocyte concentrates were tested for bacterial growth. In order to determine the frequency of false-negative BacT/ALERT signals, 1061 outdated PCs were tested during the period from May 2002 to May 2004. Eighty-eight positive signals were detected by the BacT/ALERT system, of which 12 were interpreted as truly positive. Fourteen signals were interpreted as truly false positive. Thirty-three signals were interpreted to be probably false positive. Two of 1061 outdated units tested positive, and Bacillus spp. and Staphylococcus epidermidis, respectively, were isolated from these PCs. Between 0.03% and 0.12% of the PCs were contaminated with bacteria. BacT/ALERT is an efficient tool for monitoring PCs for bacterial contamination; however, it is important to realize that false-negative results may occur.

  2. Cross-Reactivity of Pantoprazole with Three Commercial Cannabinoids Immunoassays in Urine.

    PubMed

    Gomila, Isabel; Barceló, Bernardino; Rosell, Antonio; Avella, Sonia; Sahuquillo, Laura; Dastis, Macarena

    2017-11-01

    Pantoprazole is a frequently prescribed proton pump inhibitor (PPI) commonly utilized in the management of gastrointestinal symptoms. Few substances have proved to cause a false-positive cannabinoid urine screen. However, a case of false-positive urine cannabinoid screen in a patient who received a pantoprazole dose has been recently published. The purpose of this study was to determine the potential cross-reactivity of pantoprazole in the cannabinoid immunoassays: Alere Triage® TOX Drug Screen, KIMS® Cannabinoids II and DRI® Cannabinoids Assay. Drug-free urine to which pantoprazole was added up to 12,000 μg/mL produced negative results in the DRI® Cannabinoids and KIMS® Cannabinoids II. Alere Triage® TOX Drug Screen assay gave positive results at pantoprazole concentrations higher than 1,000 μg/mL. Urine samples from 8 pediatric patients were collected at the beginning of their pantoprazole treatment. Alere Triage® TOX Drug Screen assay produced positive test results in all patient samples and KIMS® Cannabinoids II immunoassay produced positive test results in one patient sample. None patient sample gave a false-positive result when analyzed by the DRI® Cannabinoids Assay. Our findings demonstrate that some cannabinoids immunoassays are susceptible to cross-reaction errors resulting from the presence in urine of pantoprazole and the resulting metabolism of the parent drug. Clinicians should be aware of the possibility of false-positive results for cannabinoids after a pantoprazole treatment. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Laxative-free CT colonography

    PubMed Central

    Slater, A; Betts, M; D'Costa, H

    2012-01-01

    Objectives The aim of this study was to determine if the introduction of faecal tagging to CT colonography (CTC) made the examination easier to tolerate or reduced the number of false-positives. Methods Our department changed bowel preparation for CT colonography from Picolax (Ferring Pharmaceuticals Ltd, London, UK) to Gastrografin® (Bracco Diagnostics Inc, Princeton, NJ) only with a modified diet. Questionnaires were given to a subgroup of patients within these cohorts. The numbers of false-positives were compared between two cohorts before and after this change. false-positives were defined as lesions reported on CT that were not confirmed by subsequent endoscopic examination. Polyps were matched if they were in the same or adjacent segments, and were within 5 mm of the reported size. Results 412 patients were identified from the Picolax cohort, and 116 from the Gastrografin cohort. 62 patients in each group completed questionnaires. Gastrografin produced less diarrhoea; 34% had five or more bowel motions in the previous day and night, compared with 77% for Picolax (p<0.001), although more patients found drinking it unpleasant compared with Picolax (85% reported drinking Picolax as “easy” vs 61% for Gastrografin; p=0.002). Picolax produced more non-diagnostic examinations, although this difference was not statistically significant. There was not a significant reduction in the numbers of false-positives (2 out of 112 for Gastrografin group, 14 out of 389 for the Picolax group; p=0.54). Conclusion Switching from Picolax to Gastrografin as a CTC preparation technique produced less diarrhoea, but did not reduce the number of false-positives. PMID:22167512

  4. Where Have All the Interactions Gone? Estimating the Coverage of Two-Hybrid Protein Interaction Maps

    PubMed Central

    Huang, Hailiang; Jedynak, Bruno M; Bader, Joel S

    2007-01-01

    Yeast two-hybrid screens are an important method for mapping pairwise physical interactions between proteins. The fraction of interactions detected in independent screens can be very small, and an outstanding challenge is to determine the reason for the low overlap. Low overlap can arise from either a high false-discovery rate (interaction sets have low overlap because each set is contaminated by a large number of stochastic false-positive interactions) or a high false-negative rate (interaction sets have low overlap because each misses many true interactions). We extend capture–recapture theory to provide the first unified model for false-positive and false-negative rates for two-hybrid screens. Analysis of yeast, worm, and fly data indicates that 25% to 45% of the reported interactions are likely false positives. Membrane proteins have higher false-discovery rates on average, and signal transduction proteins have lower rates. The overall false-negative rate ranges from 75% for worm to 90% for fly, which arises from a roughly 50% false-negative rate due to statistical undersampling and a 55% to 85% false-negative rate due to proteins that appear to be systematically lost from the assays. Finally, statistical model selection conclusively rejects the Erdös-Rényi network model in favor of the power law model for yeast and the truncated power law for worm and fly degree distributions. Much as genome sequencing coverage estimates were essential for planning the human genome sequencing project, the coverage estimates developed here will be valuable for guiding future proteomic screens. All software and datasets are available in Datasets S1 and S2, Figures S1–S5, and Tables S1−S6, and are also available from our Web site, http://www.baderzone.org. PMID:18039026

  5. Models for Threat Assessment in Networks

    DTIC Science & Technology

    2006-09-01

    Software International and Command AntiVirus . [Online]. Available: http://www.commandsoftware.com/virus/newlove.html [38] C. Ng and P. Ferrie. (2000...28 2.3 False positive trends across all population sizes for r=0.7 and m=0.1 . . . . 33 2.4 False negative trends across all population...benefits analysis is often performed to determine the list of mitigation procedures. Traditionally, risk assessment has been done in part with software

  6. False Position, Double False Position and Cramer's Rule

    ERIC Educational Resources Information Center

    Boman, Eugene

    2009-01-01

    We state and prove the methods of False Position (Regula Falsa) and Double False Position (Regula Duorum Falsorum). The history of both is traced from ancient Egypt and China through the work of Fibonacci, ending with a connection between Double False Position and Cramer's Rule.

  7. The Diagnostic Validity of Citric Acid-Free, High Dose (13)C-Urea Breath Test After Helicobacter pylori Eradication in Korea.

    PubMed

    Kwon, Yong Hwan; Kim, Nayoung; Lee, Ju Yup; Choi, Yoon Jin; Yoon, Kichul; Hwang, Jae Jin; Lee, Hyun Joo; Lee, AeRa; Jeong, Yeon Sang; Oh, Sooyeon; Yoon, Hyuk; Shin, Cheol Min; Park, Young Soo; Lee, Dong Ho

    2015-06-01

    The (13)C-urea breath test ((13)C-UBT) is a noninvasive method for diagnosing Helicobacter pylori (H. pylori) infection. The aims of this study were to evaluate the diagnostic validity of the (13)C-UBT cutoff value and to identify influencing clinical factors responsible for aberrant results. (13)C-UBT (UBiTkit; Otsuka Pharmaceutical, cutoff value: 2.5‰) results in the range 2.0‰ to 10.0‰ after H. pylori eradication therapy were compared with the results of endoscopic biopsy results of the antrum and body. Factors considered to affect test results adversely were analyzed. Among patients with a positive (13)C-UBT result (2.5‰ to 10.0‰, n = 223) or a negative (13)C-UBT result (2.0‰ to < 2.5‰, n = 66) after H. pylori eradication, 73 patients (34.0%) were false positive, and one (1.5%) was false negative as determined by endoscopic biopsy. The sensitivity, specificity, false-positive rate, and false-negative rate for a cutoff value of 2.5‰ were 99.3%, 47.1%, 52.9%, and 0.7%, respectively, and positive and negative predictive values of the (13)C-UBT were 67.3% and 98.5%, respectively. Multivariate analysis showed that a history of two or more previous H. pylori eradication therapies (OR = 2.455, 95%CI = 1.299-4.641) and moderate to severe gastric intestinal metaplasia (OR = 3.359, 95%CI = 1.572-7.178) were associated with a false-positive (13)C-UBT result. The (13)C-UBT cutoff value currently used has poor specificity for confirming H. pylori status after eradication, and this lack of specificity is exacerbated in patients that have undergone multiple prior eradication therapies and in patients with moderate to severe gastric intestinal metaplasia. In addition, the citric-free (13)C-UBT would increase a false-positive (13)C-UBT result. © 2015 John Wiley & Sons Ltd.

  8. New Constraints on the False Positive Rate for Short-Period Kepler Planet Candidates

    NASA Astrophysics Data System (ADS)

    Colón, Knicole D.; Morehead, Robert C.; Ford, Eric B.

    2015-01-01

    The Kepler space mission has discovered thousands of potential planets orbiting other stars, thereby setting the stage for in-depth studies of different populations of planets. We present new multi-wavelength transit photometry of small (Rp < 6 Earth radii), short-period (P < 6 days) Kepler planet candidates acquired with the Gran Telescopio Canarias. Multi-wavelength transit photometry allows us to search for wavelength-dependent transit depths and subsequently identify eclipsing binary false positives (which are especially prevalent at the shortest orbital periods). We combine these new observations of three candidates with previous results for five other candidates (Colón & Ford 2011 and Colón, Ford, & Morehead 2012) to provide new constraints on the false positive rate for small, close-in candidates. In our full sample, we identify four candidates as viable planets and four as eclipsing binary false positives. We therefore find a higher false positive rate for small, close-in candidates compared to the lower false positive rate of ~10% determined by other studies for the full sample of Kepler planet candidates (e.g. Fressin et al. 2013). We also discuss the dearth of known planets with periods less than ~2.5 days and radii between ~3 and 11 Earth radii (the so-called 'sub-Jovian desert'), since the majority of the candidates in our study are located in or around this 'desert.' The lack of planets with these orbital and physical properties is not expected to be due to observational bias, as short-period planets are generally easier to detect (especially if they are larger or more massive than Earth). We consider the implications of our results for the other ~20 Kepler planet candidates located in this desert. Characterizing these candidates will allow us to better understand the formation processes of this apparently rare class of planets.

  9. Histoplasma Urinary Antigen Testing Obviates the Need for Coincident Serum Antigen Testing.

    PubMed

    Libert, Diane; Procop, Gary W; Ansari, Mohammad Q

    2018-03-07

    Serum and urine antigen (SAg, UAg) detection are common tests for Histoplasma capsulatum. UAg detection is more widely used and reportedly has a higher sensitivity. We investigated whether SAg detection contributes meaningfully to the initial evaluation of patients with suspected histoplasmosis. We reviewed 20,285 UAg and 1,426 SAg tests ordered from 1997 to 2016 and analyzed paired UAg and SAg tests completed on the same patient within 1 week. We determined the positivity rate for each test. Of 601 paired specimens, 542 were concurrent negatives and 48 were concurrent positives (98% agreement). Medical records were available for eight of 11 pairs with discrepant results. UAg was falsely positive in six instances, truly positive once, and falsely negative once. These findings support using a single antigen detection test, rather than both UAg and SAg, as an initial screen for suspected histoplasmosis. This aligns with the current practice of most physicians.

  10. The Determination of Hydrogen Sulfide in Stack Gases, Iodometric Titration After Sulfite Removal.

    ERIC Educational Resources Information Center

    Robles, E. G.

    The determination of hydrogen sulfide in effluents from coal-fired furnaces and incinerators is complicated by the presence of sulfur oxides (which form acids). Organic compounds also may interfere with or prevent the formation of the cadmium sulfide precipitate or give false positive results because of reaction with iodine. The report presents a…

  11. Microscopic diagnosis of vulvovaginal candidiasis in stained vaginal smears by Dutch general practitioners.

    PubMed

    Engberts, Marian K; Goedbloed, Annelize F; van Haaften, Maarten; van Haaften, Mathilde; Boon, Mathilde E; Boon, Maarten E; Heintz, Peter M

    2007-01-01

    To determine the accuracy of the microscopic diagnosis of vulvovaginal candidiasis (presence of [pseudo] hyphae and blastospores) in stained vaginal smears in clinical practice. General practitioners trained in diagnosing vulvovaginal candidiasis performed microscopy of 324 stained vaginal smears. These smears were sent to the pathologist for confirmation of the microscopic diagnosis of the clinician; cytologic diagnosis by the pathologist was considered the gold standard. In 104 of the 342 cases Candida was established by the pathologist. The clinicians made 24 false positive and 50 false negative diagnoses of Candida. Sensitivity and specificity of the microscopic diagnoses of the clinicians were 52% and 89%, respectively. The most frequent reason for a false positive diagnosis was presence of hairs, whereas the most frequent reason for a false negative diagnosis was understaining of the smear. This study shows that even in stained smears it is difficult for clinicians to recognize blastospores and (pseudo)hyphae. Efforts are clearly needed to improve the quality of the clinical diagnosis of vulvovaginal candidiasis.

  12. Differential specificity of selective culture media for enumeration of pathogenic vibrios: advantages and limitations of multi-plating methods.

    PubMed

    Nigro, Olivia D; Steward, Grieg F

    2015-04-01

    Plating environmental samples on vibrio-selective chromogenic media is a commonly used technique that allows one to quickly estimate concentrations of putative vibrio pathogens or to isolate them for further study. Although this approach is convenient, its usefulness depends directly on how well the procedure selects against false positives. We tested whether a chromogenic medium, CHROMagar Vibrio (CaV), used alone (single-plating) or in combination (double-plating) with a traditional medium thiosulfate-citrate-bile-salts (TCBS), could improve the discrimination among three pathogenic vibrio species (Vibrio cholerae, Vibrio parahaemolyticus, and Vibrio vulnificus) and thereby decrease the number of false-positive colonies that must be screened by molecular methods. Assays were conducted on water samples from two estuarine environments (one subtropical, one tropical) in a variety of seasonal conditions. The results of the double-plating method were confirmed by PCR and 16S rRNA sequencing. Our data indicate that there is no significant difference in the false-positive rate between CaV and TCBS when using a single-plating technique, but determining color changes on the two media sequentially (double-plating) reduced the rate of false positive identification in most cases. The improvement achieved was about two-fold on average, but varied greatly (from 0- to 5-fold) and depended on the sampling time and location. The double-plating method was most effective for V. vulnificus in warm months, when overall V. vulnificus abundance is high (false positive rates as low as 2%, n=178). Similar results were obtained for V. cholerae (minimum false positive rate of 16%, n=146). In contrast, the false positive rate for V. parahaemolyticus was always high (minimum of 59%, n=109). Sequence analysis of false-positive isolates indicated that the majority of confounding isolates are from the Vibrionaceae family, however, members of distantly related bacterial groups were also able to grow on vibrio-selective media, even when using the double-plating method. In conclusion, the double-plating assay is a simple means to increase the efficiency of identifying pathogenic vibrios in aquatic environments and to reduce the number of molecular assays required for identity confirmation. However, the high spatial and temporal variability in the performance of the media mean that molecular approaches are still essential to obtain the most accurate vibrio abundance estimates from environmental samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Rapid Identification of Laboratory Contamination with Mycobacterium tuberculosis Using Variable Number Tandem Repeat Analysis

    PubMed Central

    Gascoyne-Binzi, Deborah M.; Barlow, Rachael E. L.; Frothingham, Richard; Robinson, Grant; Collyns, Timothy A.; Gelletlie, Ruth; Hawkey, Peter M.

    2001-01-01

    Compared with solid media, broth-based mycobacterial culture systems have increased sensitivity but also have higher false-positive rates due to cross-contamination. Systematic strain typing is rarely undertaken because the techniques are technically demanding and the data are difficult to organize. Variable number tandem repeat (VNTR) analysis by PCR is rapid and reproducible. The digital profile is easily manipulated in a database. We undertook a retrospective study of Mycobacterium tuberculosis isolates collected over an 18-month period following the introduction of the BACTEC MGIT 960 system. VNTR allele profiles were determined with early positive broth cultures and entered into a database with the specimen processing date and other specimen data. We found 36 distinct VNTR profiles in cultures from 144 patients. Three common VNTR profiles accounted for 45% of true-positive cases. By combining VNTR results with specimen data, we identified nine cross-contamination incidents, six of which were previously unsuspected. These nine incidents resulted in 34 false-positive cultures for 29 patients. False-positive cultures were identified for three patients who had previously been culture positive for tuberculosis and were receiving treatment. Identification of cross-contamination incidents requires careful documentation of specimen data and good communication between clinical and laboratory staff. Automated broth culture systems should be supplemented with molecular analysis to identify cross-contamination events. VNTR analysis is reproducible and provides timely results when applied to early positive broth cultures. This method should ensure that patients are not placed on unnecessary tuberculosis therapy or that cases are not falsely identified as treatment failures. In addition, areas where existing procedures may be improved can be identified. PMID:11136751

  14. Detecting false positive sequence homology: a machine learning approach.

    PubMed

    Fujimoto, M Stanley; Suvorov, Anton; Jensen, Nicholas O; Clement, Mark J; Bybee, Seth M

    2016-02-24

    Accurate detection of homologous relationships of biological sequences (DNA or amino acid) amongst organisms is an important and often difficult task that is essential to various evolutionary studies, ranging from building phylogenies to predicting functional gene annotations. There are many existing heuristic tools, most commonly based on bidirectional BLAST searches that are used to identify homologous genes and combine them into two fundamentally distinct classes: orthologs and paralogs. Due to only using heuristic filtering based on significance score cutoffs and having no cluster post-processing tools available, these methods can often produce multiple clusters constituting unrelated (non-homologous) sequences. Therefore sequencing data extracted from incomplete genome/transcriptome assemblies originated from low coverage sequencing or produced by de novo processes without a reference genome are susceptible to high false positive rates of homology detection. In this paper we develop biologically informative features that can be extracted from multiple sequence alignments of putative homologous genes (orthologs and paralogs) and further utilized in context of guided experimentation to verify false positive outcomes. We demonstrate that our machine learning method trained on both known homology clusters obtained from OrthoDB and randomly generated sequence alignments (non-homologs), successfully determines apparent false positives inferred by heuristic algorithms especially among proteomes recovered from low-coverage RNA-seq data. Almost ~42 % and ~25 % of predicted putative homologies by InParanoid and HaMStR respectively were classified as false positives on experimental data set. Our process increases the quality of output from other clustering algorithms by providing a novel post-processing method that is both fast and efficient at removing low quality clusters of putative homologous genes recovered by heuristic-based approaches.

  15. False Positivity of Non-Targeted Infections in Malaria Rapid Diagnostic Tests: The Case of Human African Trypanosomiasis

    PubMed Central

    Gillet, Philippe; Mumba Ngoyi, Dieudonné; Lukuka, Albert; Kande, Viktor; Atua, Benjamin; van Griensven, Johan; Muyembe, Jean-Jacques; Jacobs, Jan; Lejon, Veerle

    2013-01-01

    Background In endemic settings, diagnosis of malaria increasingly relies on the use of rapid diagnostic tests (RDTs). False positivity of such RDTs is poorly documented, although it is especially relevant in those infections that resemble malaria, such as human African trypanosomiasis (HAT). We therefore examined specificity of malaria RDT products among patients infected with Trypanosoma brucei gambiense. Methodology/Principal Findings Blood samples of 117 HAT patients and 117 matched non-HAT controls were prospectively collected in the Democratic Republic of the Congo. Reference malaria diagnosis was based on real-time PCR. Ten commonly used malaria RDT products were assessed including three two-band and seven three-band products, targeting HRP-2, Pf-pLDH and/or pan-pLDH antigens. Rheumatoid factor was determined in PCR negative subjects. Specificity of the 10 malaria RDT products varied between 79.5 and 100% in HAT-negative controls and between 11.3 and 98.8% in HAT patients. For seven RDT products, specificity was significantly lower in HAT patients compared to controls. False positive reactions in HAT were mainly observed for pan-pLDH test lines (specificities between 13.8 and 97.5%), but also occurred frequently for the HRP-2 test line (specificities between 67.9 and 98.8%). The Pf-pLDH test line was not affected by false-positive lines in HAT patients (specificities between 97.5 and 100%). False positivity was not associated to rheumatoid factor, detected in 7.6% of controls and 1.2% of HAT patients. Conclusions/Significance Specificity of some malaria RDT products in HAT was surprisingly low, and constitutes a risk for misdiagnosis of a fatal but treatable infection. Our results show the importance to assess RDT specificity in non-targeted infections when evaluating diagnostic tests. PMID:23638201

  16. Evaluation of exome variants using the Ion Proton Platform to sequence error-prone regions.

    PubMed

    Seo, Heewon; Park, Yoomi; Min, Byung Joo; Seo, Myung Eui; Kim, Ju Han

    2017-01-01

    The Ion Proton sequencer from Thermo Fisher accurately determines sequence variants from target regions with a rapid turnaround time at a low cost. However, misleading variant-calling errors can occur. We performed a systematic evaluation and manual curation of read-level alignments for the 675 ultrarare variants reported by the Ion Proton sequencer from 27 whole-exome sequencing data but that are not present in either the 1000 Genomes Project and the Exome Aggregation Consortium. We classified positive variant calls into 393 highly likely false positives, 126 likely false positives, and 156 likely true positives, which comprised 58.2%, 18.7%, and 23.1% of the variants, respectively. We identified four distinct error patterns of variant calling that may be bioinformatically corrected when using different strategies: simplicity region, SNV cluster, peripheral sequence read, and base inversion. Local de novo assembly successfully corrected 201 (38.7%) of the 519 highly likely or likely false positives. We also demonstrate that the two sequencing kits from Thermo Fisher (the Ion PI Sequencing 200 kit V3 and the Ion PI Hi-Q kit) exhibit different error profiles across different error types. A refined calling algorithm with better polymerase may improve the performance of the Ion Proton sequencing platform.

  17. Occupancy models for data with false positive and false negative errors and heterogeneity across sites and surveys

    Treesearch

    Paige F.B. Ferguson; Michael J. Conroy; Jeffrey Hepinstall-Cymerman; Nigel Yoccoz

    2015-01-01

    False positive detections, such as species misidentifications, occur in ecological data, although many models do not account for them. Consequently, these models are expected to generate biased inference.The main challenge in an analysis of data with false positives is to distinguish false positive and false negative...

  18. Comparative evaluation of paired blood culture (aerobic/aerobic) and single blood culture, along with clinical importance in catheter versus peripheral line at a tertiary care hospital.

    PubMed

    Tarai, B; Das, P; Kumar, D; Budhiraja, S

    2012-01-01

    Paired blood culture (PBC) is uncommon practice in hospitals in India, leading to delayed and inadequate diagnosis. Also contamination remains a critical determinant in hampering the definitive diagnosis. To establish the need of PBC over single blood culture (SBC) along with the degree of contamination, this comparative retrospective study was initiated. We processed 2553 PBC and 4350 SBC in BacT/ALERT 3D (bioMerieux) between October 2010 and June 2011. The positive cultures were identified in VITEK 2 Compact (bioMerieux). True positivity and contaminants were also analyzed in 486 samples received from catheter and peripheral line. Out of 2553 PBC samples, positivity was seen in 350 (13.70%). In 4350 SBC samples, positivity was seen in 200 samples (4.59%). In PBC true pathogens were 267 (10.45%) and contaminants were 83 (3.25%), whereas in SBC 153 (3.51%) were true positives and contaminants were 47 (1.08%). Most of the blood cultures (99.27 %) grew within 72 h and 95.8% were isolated within 48 h. In 486 PBCs received from catheter/periphery (one each), catheter positivity was found in 85 (true positives were 48, false positives 37). In peripheral samples true positives were 50 and false positives were 8. Significantly higher positive rates were seen in PBCs compared with SBCs. Automated blood culture and identification methods significantly reduced the time required for processing of samples and also facilitated yield of diverse/rare organisms. Blood culture from catheter line had higher false positives than peripheral blood culture. Thus every positive result from a catheter must be correlated with clinical findings and requires further confirmation.

  19. Direct versus indirect molecular diagnosis of fragile X mental retardation in 40 German families at risk.

    PubMed

    Knobloch, O; Pelz, F; Wick, U; Nelson, D L; Zoll, B

    1993-03-01

    In order to test whether the direct molecular diagnostic approach for fragile X mental retardation (Martin-Bell syndrome, MBS) really makes diagnosis of this disease more precise, we evaluated the results of direct diagnosis in 40 German families at risk together with the results of an earlier study with closely linked flanking markers in the same families. Of 84 men analysed, 43 showed clinical signs. In 39 of these affected men the disease could be confirmed by direct diagnosis. Compared to cytogenetic data, one man was false negative and two were false positive. Two men, whose status could not be determined by means of RFLP data, proved to be normal transmitting males (NTMs). However, the possibility of being an NTM had to be rejected in one case on RFLP data. Fragile X syndrome could be confirmed in 10 of the 13 women with clinical signs. Compared to cytogenetic data there were three cases of false negative results and one of false positive. All 36 obligate carrier women were detected by the direct approach. In addition, 22 women were newly identified as normal transmitting females (NTFs), among them one woman who could not be identified by cytogenetic means or by analysis with closely linked markers. These findings are discussed in view of the relative reliability of the three diagnostic approaches to MBS. Special attention is drawn to the significance of false negative and false positive results in direct diagnosis.

  20. 5 CFR 339.203 - Physical requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Physical requirements. 339.203 Section... QUALIFICATION DETERMINATIONS Physical and Medical Qualifications § 339.203 Physical requirements. Agencies are authorized to establish physical requirements for individual positions without OPM approval when such...

  1. 5 CFR 339.203 - Physical requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Physical requirements. 339.203 Section... QUALIFICATION DETERMINATIONS Physical and Medical Qualifications § 339.203 Physical requirements. Agencies are authorized to establish physical requirements for individual positions without OPM approval when such...

  2. 5 CFR 339.203 - Physical requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Physical requirements. 339.203 Section... QUALIFICATION DETERMINATIONS Physical and Medical Qualifications § 339.203 Physical requirements. Agencies are authorized to establish physical requirements for individual positions without OPM approval when such...

  3. 5 CFR 339.203 - Physical requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 1 2013-01-01 2013-01-01 false Physical requirements. 339.203 Section... QUALIFICATION DETERMINATIONS Physical and Medical Qualifications § 339.203 Physical requirements. Agencies are authorized to establish physical requirements for individual positions without OPM approval when such...

  4. 5 CFR 339.203 - Physical requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Physical requirements. 339.203 Section... QUALIFICATION DETERMINATIONS Physical and Medical Qualifications § 339.203 Physical requirements. Agencies are authorized to establish physical requirements for individual positions without OPM approval when such...

  5. Fine-Needle Aspiration, Touch Imprint, and Crush Preparation Cytology for Diagnosing Thyroid Malignancies in Thyroid Nodules.

    PubMed

    Ahmadinejad, Mojtaba; Aliepour, Asghar; Anbari, Khatereh; Kaviani, Mojhgan; Ganjizadeh, Hasan; Nadri, Sedigheh; Foroutani, Niloufar; Meysami, Masoumeh; Almasi, Vahid

    2015-12-01

    Several methods are used to evaluate the thyroid nodules. The aim of this study was to determine the sensitivity, specificity, false positive and negative rates, positive predictive value (PPV), and negative predictive value (NPV) of touch imprint, crush preparation, and fine-needle aspiration (FNA) methods. This cross-sectional study was done in Shohada-ye Ashayer University Hospital in Khorramabad. All the patients who underwent thyroid surgery due to thyroid nodules in this hospital between March and September 2011 were evaluated. The thyroid nodules of all the patients were evaluated by touch imprint, crush preparation, FNA, and permanent pathology methods. Finally, the results of the first three methods were compared with the result of permanent pathology method. The mean age of 104 patients who underwent thyroid surgery was 42.6 ± 11.9 years old. Based on permanent pathology, touch imprint, crush preparation, and FNA methods, 15.3, 6.25, 6.25, and 4.4 % of thyroid nodules were malignant, respectively. Sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of FNA biopsy were 62.5, 100, 0, 37.5, 100, and 95.3 %, respectively. Also, sensitivity, specificity, false positive rate, false negative rate, PPV, and NPV of touch imprint and crush preparation were equal and were 80, 100, 0, 20, 100, and 96.7 %, respectively. Using touch imprint and crush preparation in evaluation of thyroid nodules for rapid evaluation of these nodules in operating rooms seems to be logical, and it can prevent further surgeries.

  6. Effect of obesity on preterm delivery prediction by transabdominal recording of uterine electromyography.

    PubMed

    Lucovnik, Miha; Chambliss, Linda R; Blumrick, Richard; Balducci, James; Gersak, Ksenija; Garfield, Robert E

    2016-10-01

    It has been shown that noninvasive uterine electromyography (EMG) can identify true preterm labor more accurately than methods available to clinicians today. The objective of this study was to evaluate the effect of body mass index (BMI) on the accuracy of uterine EMG in predicting preterm delivery. Predictive values of uterine EMG for preterm delivery were compared in obese versus overweight/normal BMI patients. Hanley-McNeil test was used to compare receiver operator characteristics curves in these groups. Previously reported EMG cutoffs were used to determine groups with false positive/false negative and true positive/true negative EMG results. BMI in these groups was compared with Student t test (p < 0.05 significant). A total of 88 patients were included: 20 obese, 64 overweight, and four with normal BMI. EMG predicted preterm delivery within 7 days with area under the curve = 0.95 in the normal/overweight group, and with area under the curve = 1.00 in the obese group (p = 0.08). Six patients in true preterm labor (delivering within 7 days from EMG measurement) had low EMG values (false negative group). There were no false positive results. No significant differences in patient's BMI were noted between false negative group patients and preterm labor patients with high EMG values (true positive group) and nonlabor patients with low EMG values (true negative group; p = 0.32). Accuracy of noninvasive uterine EMG monitoring and its predictive value for preterm delivery are not affected by obesity. Copyright © 2016. Published by Elsevier B.V.

  7. Experimental identification of specificity determinants in the domain linker of a LacI/GalR protein: bioinformatics-based predictions generate true positives and false negatives.

    PubMed

    Meinhardt, Sarah; Swint-Kruse, Liskin

    2008-12-01

    In protein families, conserved residues often contribute to a common general function, such as DNA-binding. However, unique attributes for each homolog (e.g. recognition of alternative DNA sequences) must arise from variation in other functionally-important positions. The locations of these "specificity determinant" positions are obscured amongst the background of varied residues that do not make significant contributions to either structure or function. To isolate specificity determinants, a number of bioinformatics algorithms have been developed. When applied to the LacI/GalR family of transcription regulators, several specificity determinants are predicted in the 18 amino acids that link the DNA-binding and regulatory domains. However, results from alternative algorithms are only in partial agreement with each other. Here, we experimentally evaluate these predictions using an engineered repressor comprising the LacI DNA-binding domain, the LacI linker, and the GalR regulatory domain (LLhG). "Wild-type" LLhG has altered DNA specificity and weaker lacO(1) repression compared to LacI or a similar LacI:PurR chimera. Next, predictions of linker specificity determinants were tested, using amino acid substitution and in vivo repression assays to assess functional change. In LLhG, all predicted sites are specificity determinants, as well as three sites not predicted by any algorithm. Strategies are suggested for diminishing the number of false negative predictions. Finally, individual substitutions at LLhG specificity determinants exhibited a broad range of functional changes that are not predicted by bioinformatics algorithms. Results suggest that some variants have altered affinity for DNA, some have altered allosteric response, and some appear to have changed specificity for alternative DNA ligands.

  8. Rubella Surveillance and Diagnostic Testing among a Low-Prevalence Population, New York City, 2012–2013

    PubMed Central

    Zucker, Jane R.; Giancotti, Francesca R.; Abernathy, Emily; Icenogle, Joseph; Rakeman, Jennifer L.; Rosen, Jennifer B.

    2017-01-01

    ABSTRACT The New York City Department of Health and Mental Hygiene (DOHMH) receives clinical and laboratory reports for rubella. Because rubella immunoglobulin M (IgM) assays may produce false-positive results and rubella infections may be asymptomatic, interpretation of positive IgM results can be challenging. Rubella reports received by DOHMH in 2012 to 2013 were reviewed. The rubella IgM testing purpose was determined through case investigation. Results of IgM testing by indirect enzyme-linked immunosorbent assay (ELISA) and capture enzyme immunoassay (EIA) were compared to determine positive predictive value (PPV) and specificity. DOHMH received 199 rubella reports; 2 were true cases. Of all reports, 77.9% were tested for rubella IgM erroneously, 19.6% were tested for diagnostic purposes, 2.0% had unknown test purpose, and 0.5% were not tested. PPV of indirect ELISA was 6% overall, 14% for diagnostic tests, and 0% for tests ordered erroneously. PPV of capture EIA was 29% overall, 50% for diagnostic tests, and 0% for tests ordered erroneously. Overall, specificity was 52% for indirect ELISA and 85% for capture EIA. Limiting rubella IgM testing to patients for whom rubella diagnosis is suspected and using a more specific IgM assay have the potential to reduce false-positive rubella IgM results. PMID:28701468

  9. 14 CFR 135.351 - Recurrent training.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Recurrent training. 135.351 Section 135.351 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS... other review to determine the crewmember's knowledge of the aircraft and crewmember position involved...

  10. 14 CFR 135.351 - Recurrent training.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Recurrent training. 135.351 Section 135.351 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS... other review to determine the crewmember's knowledge of the aircraft and crewmember position involved...

  11. 5 CFR 319.302 - Individual qualifications.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Individual qualifications. 319.302... Individual qualifications. Agency heads are delegated authority to approve the qualifications of individuals appointed to SL and ST positions. The agency head must determine that the individual meets the...

  12. Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings.

    PubMed

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; Bria, Alessandro; Tortorella, Francesco; den Heeten, Gerard; Karssemeijer, Nico

    2017-04-01

    Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated by microcalcification detection algorithms. We aim at reducing the number of obvious false-positive findings by adding an additional step in the detection method. In this step, a multiclass machine learning method is implemented in which dedicated classifiers learn to recognize the patterns of obvious false-positive subtypes that occur most frequently. The method is compared to a conventional two-class approach, where all false-positive subtypes are grouped together in one class, and to the baseline CADe system without the new false-positive removal step. The methods are evaluated on an independent dataset containing 1,542 screening examinations of which 80 examinations contain malignant microcalcifications. Analysis showed that the multiclass approach yielded a significantly higher sensitivity compared to the other two methods (P < 0.0002). At one obvious false positive per 100 images, the baseline CADe system detected 61% of the malignant examinations, while the systems with the two-class and multiclass false-positive reduction step detected 73% and 83%, respectively. Our study showed that by adding the proposed method to a CADe system, the number of obvious false positives can decrease significantly (P < 0.0002). © 2017 American Association of Physicists in Medicine.

  13. Shear wave elastography in the diagnosis of breast non-mass lesions: factors associated with false negative and false positive results.

    PubMed

    Park, So Yoon; Choi, Ji Soo; Han, Boo-Kyung; Ko, Eun Young; Ko, Eun Sook

    2017-09-01

    To investigate factors related to false shear wave elastography (SWE) results for breast non-mass lesions (NMLs) detected by B-mode US. This retrospective study enrolled 152 NMLs detected by B-mode US and later pathologically confirmed (79 malignant, 73 benign). All lesions underwent B-mode US and SWE. Quantitative (mean elasticity [E mean ]) and qualitative (maximum stiffness colour) SWE parameters were assessed, and 'E mean  > 85.1 kPa' or 'stiff colour (green to red)' determined malignancy. Final SWE results were matched to pathology results. Multivariate logistic regression analysis identified factors associated with false SWE results for diagnosis of breast NMLs. Associated calcifications (E mean : odds ratio [OR] = 7.60, P < 0.01; maximum stiffness colour: OR = 6.30, P = 0.02), in situ cancer compared to invasive cancer (maximum stiffness colour: OR = 5.29, P = 0.02), and lesion size (E mean : OR = 0.90, P < 0.01; maximum stiffness colour: OR = 0.91, P = 0.01) were significantly associated with false negative SWE results for malignant NMLs. Distance from the nipple (E mean : OR = 0.84, P = 0.03; maximum stiffness colour: OR = 0.93, P = 0.04) was significantly associated with false positive SWE results for benign NMLs. Presence of associated calcifications, absence of the invasive component, and smaller lesion size for malignant NMLs and shorter distance from the nipple for benign NMLs are factors significantly associated with false SWE results. • Calcification and size are associated with false negative SWE in malignant NMLs. • In situ cancer is associated with false negative SWE in malignant NMLs. • Distance from the nipple is associated with false positive SWE in benign NMLs. • These factors need consideration when performing SWE on breast NMLs.

  14. A prospective study: Is handheld micropower impulse radar technology (Pneumoscan) a promising method to detect pneumothorax?

    PubMed

    Hocagil, Hilal; Hocagil, Abdullah Cüneyt; Karacabey, Sinan; Akkaya, Tuğba; Şimşek, Gözde; Sanrı, Erkman

    2015-09-01

    This study aimed to discuss the effectiveness of Pneumoscan working with micropower impulse radar (MIR) technology in diagnosing pneumothorax (PTX) in the emergency department. Patients with suspicion of PTX and indication for thorax tomography (CT) were included into the study. Findings of the Thorax CT were compared with the results of Pneumoscan. Chi-square and Fisher's exact tests were used in categorical variables. One hundred and fifteen patients were included into the study group; twelve patients presented with PTX diagnosed by CT, 10 of which were detected by Pneumoscan. Thirty-six true negative results, sixty-seven false positive results, and two false negative results were obtained, which resulted in an overall sensitivity of 83.3%, specificity of 35.0% for Pneumoscan. There was no statistically significant difference between the effectiveness of Pneumoscan and CT on the detection of PTX (p=0.33). There was no difference between the size of PTX diagnosed by CT and PTX diagnosed by Pneumoscan (p=0.47). There was no statistically significant difference between Pneumoscan and CT on detecting the localisation of the PTX (p=1.00). For the 10 cases diagnosed by Pneumoscan, mean chest wall thickness was determined as 50.3 mm while mean chest wall thickness for two false negatives diagnosed by Pneumoscan was 56.5 mm. However, no statistically significant difference was found between the chest wall thickness and the effectiveness of Pneumoscan on the detection of the PTX (p=0.77). Among sixty-seven false positives diagnosed by Pneumoscan, 46.3% had additional medical signs such as bronchiectasis, pulmonary consolidation, pulmonary edema or pulmonary tumor when they had a reading with CT. The relationship between having additional medical signs at the reading with CT and the effectiveness of Pneumoscan on the detection of the PTX was investigated and no significant difference was found (p=0.472). Using Pneumoscan to detect PTX is controversial since the device has a high false positive ratio. Wherein, false positive diagnosis can cause unjustifiable chest tube insertion. In addition, the device failed to show the size of the PTX, and therefore, it did not aid in determining the treatment and prognosis on contrary to traditional diagnostic methods. The findings could not demonstrate that the device was efficient in emergency care. Further studies and increasing experience may change this outcome in upcoming years.

  15. Evaluation of inadequate, indeterminate, false-negative and false-positive cases in cytological examination for breast cancer according to histological type

    PubMed Central

    2012-01-01

    Background We previously investigated the current status of breast cytology cancer screening at seven institutes in our area of southern Fukuoka Prefecture, and found some differences in diagnostic accuracy among the institutions. In the present study, we evaluated the cases involved and noted possible reasons for their original cytological classification as inadequate, indeterminate, false-negative and false-positive according to histological type. Methods We evaluated the histological findings in 5693 individuals who underwent cytological examination for breast cancer (including inadequate, indeterminate, false-negative and false-positive cases), to determine the most common histological types and/or features in these settings and the usefulness/limitations of cytological examination for the diagnosis of breast cancer. Results Among 1152 cytologically inadequate cases, histology revealed that 75/173 (43.6%) cases were benign, including mastopathy (fibrocystic disease) in 38.6%, fibroadenoma in 24.0% and papilloma in 5.3%. Ninety-five of 173 (54.9%) cases were histologically malignant, with scirrhous growing type, invasive ductal carcinoma (SIDC) being significantly more frequent (49.5%) than papillotubular growing type (Papi-tub) (P < 0.0001), solid-tubular growing type (P = 0.0001) and ductal carcinoma in situ (DCIS) (P = 0.0001). Among 458 indeterminate cases, 54/139 (38.8%) were histologically benign (mastopathy, 30.0%; fibroadenoma, 27.8%; papilloma, 26.0%) and 73/139 (52.5%) were malignant, with SIDC being the most frequent malignant tumor (37.0%). Among 52 false-negative cases, SIDC was significantly more frequent (42.3%) than DCIS (P = 0.0049) and Papi-tub (P = 0.001). There were three false-positive cases, with one each of fibroadenoma, epidermal cyst and papilloma. Conclusions The inadequate, indeterminate, false-negative and false-positive cases showed similar histological types, notably SIDC for malignant tumors, and mastopathy, fibroadenoma and papilloma for benign cases. We need to pay particular attention to the collection and assessment of aspirates for these histological types of breast disease. In particular, several inadequate, indeterminate and false-negative cases with samples collected by aspiration were diagnosed as SIDC. These findings should encourage the use of needle biopsy rather than aspiration when this histological type is identified on imaging. Namely, good communication between clinicians and pathological staff, and triple assessment (i.e., clinical, pathological and radiological assessment), are important for accurate diagnosis of aspiration samples. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/7349809170055423 PMID:22607447

  16. Optimising in situ gamma measurements to identify the presence of radioactive particles in land areas.

    PubMed

    Rostron, Peter D; Heathcote, John A; Ramsey, Michael H

    2014-12-01

    High-coverage in situ surveys with gamma detectors are the best means of identifying small hotspots of activity, such as radioactive particles, in land areas. Scanning surveys can produce rapid results, but the probabilities of obtaining false positive or false negative errors are often unknown, and they may not satisfy other criteria such as estimation of mass activity concentrations. An alternative is to use portable gamma-detectors that are set up at a series of locations in a systematic sampling pattern, where any positive measurements are subsequently followed up in order to determine the exact location, extent and nature of the target source. The preliminary survey is typically designed using settings of detector height, measurement spacing and counting time that are based on convenience, rather than using settings that have been calculated to meet requirements. This paper introduces the basis of a repeatable method of setting these parameters at the outset of a survey, for pre-defined probabilities of false positive and false negative errors in locating spatially small radioactive particles in land areas. It is shown that an un-collimated detector is more effective than a collimated detector that might typically be used in the field. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Validation of an Arab name algorithm in the determination of Arab ancestry for use in health research.

    PubMed

    El-Sayed, Abdulrahman M; Lauderdale, Diane S; Galea, Sandro

    2010-12-01

    Data about Arab-Americans, a growing ethnic minority, are not routinely collected in vital statistics, registry, or administrative data in the USA. The difficulty in identifying Arab-Americans using publicly available data sources is a barrier to health research about this group. Here, we validate an empirically based probabilistic Arab name algorithm (ANA) for identifying Arab-Americans in health research. We used data from all Michigan birth certificates between 2000 and 2005. Fathers' surnames and mothers' maiden names were coded as Arab or non-Arab according to the ANA. We calculated sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) of Arab ethnicity inferred using the ANA as compared to self-reported Arab ancestry. Statewide, the ANA had a specificity of 98.9%, a sensitivity of 50.3%, a PPV of 57.0%, and an NPV of 98.6%. Both the false-positive and false-negative rates were higher among men than among women. As the concentration of Arab-Americans in a study locality increased, the ANA false-positive rate increased and false-negative rate decreased. The ANA is highly specific but only moderately sensitive as a means of detecting Arab ancestry. Future research should compare health characteristics among Arab-American populations defined by Arab ancestry and those defined by the ANA.

  18. Automated microaneurysm detection method based on double ring filter in retinal fundus images

    NASA Astrophysics Data System (ADS)

    Mizutani, Atsushi; Muramatsu, Chisako; Hatanaka, Yuji; Suemori, Shinsuke; Hara, Takeshi; Fujita, Hiroshi

    2009-02-01

    The presence of microaneurysms in the eye is one of the early signs of diabetic retinopathy, which is one of the leading causes of vision loss. We have been investigating a computerized method for the detection of microaneurysms on retinal fundus images, which were obtained from the Retinopathy Online Challenge (ROC) database. The ROC provides 50 training cases, in which "gold standard" locations of microaneurysms are provided, and 50 test cases without the gold standard locations. In this study, the computerized scheme was developed by using the training cases. Although the results for the test cases are also included, this paper mainly discusses the results for the training cases because the "gold standard" for the test cases is not known. After image preprocessing, candidate regions for microaneurysms were detected using a double-ring filter. Any potential false positives located in the regions corresponding to blood vessels were removed by automatic extraction of blood vessels from the images. Twelve image features were determined, and the candidate lesions were classified into microaneurysms or false positives using the rule-based method and an artificial neural network. The true positive fraction of the proposed method was 0.45 at 27 false positives per image. Forty-two percent of microaneurysms in the 50 training cases were considered invisible by the consensus of two co-investigators. When the method was evaluated for visible microaneurysms, the sensitivity for detecting microaneurysms was 65% at 27 false positives per image. Our computerized detection scheme could be improved for helping ophthalmologists in the early diagnosis of diabetic retinopathy.

  19. Results of newborn screening for hearing loss: effects on the family in the first 2 years of life.

    PubMed

    Vohr, Betty R; Jodoin-Krauzyk, Julie; Tucker, Richard; Johnson, Mary Jane; Topol, Deborah; Ahlgren, Marianne

    2008-03-01

    To determine whether there was increased stress and impact on the family for mothers of infants whose screening results and subsequent diagnostic findings indicated hearing loss (HL) and mothers of infants with a positive screening result who subsequently pass the rescreening (false-positive group), compared with mothers of infants who pass the initial screening (control group), when their children were aged 6 to 10, 12 to 16, and 18 to 24 months. Matched cohort analytic study. Home visits. Patients/ Mothers of 33 infants with confirmed HL, 42 infants with a false-positive screening result, and 70 infants in the control group. Screening for HL. Scores on the Parenting Stress Index and the Impact on Family-Adapted Version G. Mothers of infants in the false-positive group did not report increased stress or impact. Mothers of infants with HL reported greater financial impact, total impact, and caretaker burden compared with mothers of infants in the control group. In multivariate analysis of the total cohort, the presence of HL was associated with increased total impact on the family; a neonatal intensive care unit stay was associated with increased stress and total impact on the family; and older maternal age and greater family resources were associated with decreased stress and total impact on the family. Although a false-positive result or a pass of the screening for HL was not associated with increased stress or impact, identification of HL was independently associated with greater total impact on the family when the child was 18 to 24 months of age.

  20. A national study of breast and colorectal cancer patients' decision-making for novel personalized medicine genomic diagnostics.

    PubMed

    Issa, Amalia M; Tufail, Waqas; Atehortua, Nelson; McKeever, John

    2013-05-01

    Molecular diagnostics are increasingly being used to help guide decision-making for personalized medical treatment of breast and colorectal cancer patients. The main aim of this study was to better understand and determine breast and colorectal cancer patients' decision-making strategies and the trade-offs they make in deciding about characteristics of molecular genomic diagnostics for breast and colorectal cancer. We surveyed a nationally representative sample of 300 breast and colorectal cancer patients using a previously developed web-administered instrument. Eligibility criteria included patients aged 18 years and older with either breast or colorectal cancer. We explored several attributes and attribute levels of molecular genomic diagnostics in 20 scenarios. Our analysis revealed that both breast and colorectal cancer patients weighted the capability of molecular genomic diagnostics to determine the probability of treatment efficacy as being of greater importance than information provided to detect adverse events. The probability of either false-positive or -negative results was ranked highly as a potential barrier by both breast and colorectal patients. However, 78.6% of breast cancer patients ranked the possibility of a 'false-negative test result leading to undertreatment' higher than the 'chance of a false positive, which may lead to overtreatment' (68%). This finding contrasted with the views of colorectal cancer patients who ranked the chance of a false positive as being of greater concern than a false negative (72.8 vs 63%). Overall, cancer patients exhibited a high willingness to accept and pay for genomic diagnostic tests, especially among breast cancer patients. Cancer patients seek a test accuracy rate of 90% or higher. Breast and colorectal cancer patients' decisions about genomic diagnostics are influenced more by the probability of being cured than by avoiding potential severe adverse events. This study provides insights into the relative weight that breast and colorectal cancer patients place on various aspects of molecular genomic diagnostics, and the trade-offs they are willing to make among attributes of such tests.

  1. A retrospective comparison of false negative skin test rates in penicillin allergy, using pencilloyl-poly-lysine and minor determinants or Penicillin G, followed by open challenge.

    PubMed

    Rosenfield, Lana; Kalicinsky, Chrystyna; Warrington, Richard

    2015-01-01

    A history of penicillin allergy in patients is common, but only 10-15 % are truly allergic. While the gold standard for diagnosing penicillin allergy is challenge, it is not recommended that this be done without first carrying out diagnostic skin testing. This is carried out with the major determinant benzylpenicilloyl (PPL) and the minor determinant mixture (MDM), consisting of penilloate, penicilloate and Penicillin G. However, since availability of the MDM is limited, Penicillin G alone has been used. A retrospective chart review was carried out on patients tested for penicillin allergy in the Clinical Immunology and Allergy Clinic at the Health Sciences Centre, Winnipeg, Canada between 2005 and 2013. A total of 521 patients charts were reviewed, of whom 240 had skin testing, ImmunoCap(®) for IgE to Penicillin G and V and had oral challenges with penicillin, amoxicillin or cloxacillin. 17/240 (7.5 %) were skin test positive, 8 to PPL, 4 to MDM and 5 to Penicillin G. One was also positive on ImmunoCap(®) testing. Three patients had negative skin tests but weakly positive ImmunoCap(®). 222 patients with negative skin tests and serological tests were challenged. Of these, 12 patients reacted to challenge. Three of the challenges were equivocal. Of the nine patients with definite positive challenges, three were tested with Penicillin G and six with MDM. Therefore the false negative rates for testing were 2.3 % with PPL and Penicillin G and 6.97 % for PPL and MDM. The difference was not significant (p = 0.0856). In this group of patients with a history of penicillin allergy tested with the major determinant of benzyl penicillin and either MDM or Penicillin G, there was no difference in the rate of false negative testing, based on oral penicillin challenges. Therefore, Penicillin G can be safely used as an alternative to MDM in diagnosing penicillin allergy.

  2. Statistical approaches to account for false-positive errors in environmental DNA samples.

    PubMed

    Lahoz-Monfort, José J; Guillera-Arroita, Gurutzeta; Tingley, Reid

    2016-05-01

    Environmental DNA (eDNA) sampling is prone to both false-positive and false-negative errors. We review statistical methods to account for such errors in the analysis of eDNA data and use simulations to compare the performance of different modelling approaches. Our simulations illustrate that even low false-positive rates can produce biased estimates of occupancy and detectability. We further show that removing or classifying single PCR detections in an ad hoc manner under the suspicion that such records represent false positives, as sometimes advocated in the eDNA literature, also results in biased estimation of occupancy, detectability and false-positive rates. We advocate alternative approaches to account for false-positive errors that rely on prior information, or the collection of ancillary detection data at a subset of sites using a sampling method that is not prone to false-positive errors. We illustrate the advantages of these approaches over ad hoc classifications of detections and provide practical advice and code for fitting these models in maximum likelihood and Bayesian frameworks. Given the severe bias induced by false-negative and false-positive errors, the methods presented here should be more routinely adopted in eDNA studies. © 2015 John Wiley & Sons Ltd.

  3. Easy fix for clinical laboratories for the false-positive defect with the Abbott AxSym total beta-hCG test.

    PubMed

    Cole, Laurence A; Khanlian, Sarah A

    2004-05-01

    False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.

  4. 14 CFR 91.1107 - Recurrent training.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Recurrent training. 91.1107 Section 91.1107 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC... quiz or other review to determine the crewmember's knowledge of the aircraft and crewmember position...

  5. 14 CFR 91.1107 - Recurrent training.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Recurrent training. 91.1107 Section 91.1107 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC... quiz or other review to determine the crewmember's knowledge of the aircraft and crewmember position...

  6. 5 CFR 531.215 - Setting pay upon demotion.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Setting pay upon demotion. 531.215 Section 531.215 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PAY UNDER THE GENERAL SCHEDULE Determining Rate of Basic Pay Setting Pay When Appointment Or Position...

  7. 5 CFR 531.214 - Setting pay upon promotion.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Setting pay upon promotion. 531.214 Section 531.214 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PAY UNDER THE GENERAL SCHEDULE Determining Rate of Basic Pay Setting Pay When Appointment Or Position...

  8. A biopsymeter to support the diagnostic procedure of skin samples

    NASA Astrophysics Data System (ADS)

    Fioravanti, Valeria; Chandrashekar, Shailendra; Brandhoff, Lukas; Pucciarelli, Daniela; van den Driesche, Sander; Breiteneder, Heimo; Hafner, Christine; Vellekoop, Michael J.

    2015-06-01

    We present an infrared biopsymeter to assist pathologists in the diagnosis of melanoma presence in skin biopsies. The designed and realized system combines the features of visual inspection and physical sensing to reduce false positives and false negatives occurring during standard histopathological analyses. The biopsymeter determines the CH2-stretch ratio by infrared absorbance measurements of skin biopsies. Investigations conducted with the biopsymeter shows that malignant melanomas and melanoma metastases have higher CH2-stretch ratio values compared to healthy skin tissues.

  9. CT Colonography with Computer-aided Detection: Recognizing the Causes of False-Positive Reader Results

    PubMed Central

    Dachman, Abraham H.; Wroblewski, Kristen; Vannier, Michael W.; Horne, John M.

    2014-01-01

    Computed tomography (CT) colonography is a screening modality used to detect colonic polyps before they progress to colorectal cancer. Computer-aided detection (CAD) is designed to decrease errors of detection by finding and displaying polyp candidates for evaluation by the reader. CT colonography CAD false-positive results are common and have numerous causes. The relative frequency of CAD false-positive results and their effect on reader performance on the basis of a 19-reader, 100-case trial shows that the vast majority of CAD false-positive results were dismissed by readers. Many CAD false-positive results are easily disregarded, including those that result from coarse mucosa, reconstruction, peristalsis, motion, streak artifacts, diverticulum, rectal tubes, and lipomas. CAD false-positive results caused by haustral folds, extracolonic candidates, diminutive lesions (<6 mm), anal papillae, internal hemorrhoids, varices, extrinsic compression, and flexural pseudotumors are almost always recognized and disregarded. The ileocecal valve and tagged stool are common sources of CAD false-positive results associated with reader false-positive results. Nondismissable CAD soft-tissue polyp candidates larger than 6 mm are another common cause of reader false-positive results that may lead to further evaluation with follow-up CT colonography or optical colonoscopy. Strategies for correctly evaluating CAD polyp candidates are important to avoid pitfalls from common sources of CAD false-positive results. ©RSNA, 2014 PMID:25384290

  10. Free thyroxine concentrations by equilibrium dialysis and chemiluminescent immunoassays in 13 hypothyroid dogs positive for thyroglobulin antibody.

    PubMed

    Randolph, J F; Lamb, S V; Cheraskin, J L; Schanbacher, B J; Salerno, V J; Mack, K M; Scarlett, J M; Place, N J

    2015-01-01

    To determine if concentrations of free thyroxine (FT4) measured by semi-automated chemiluminescent immunoassay (CLIA) correspond to FT4 determined by equilibrium dialysis (ED) in hypothyroid dogs positive for thyroglobulin antibody (TGA). Thirteen TGA-positive dogs classified as hypothyroid based on subnormal FT4 concentrations by ED. Qualitative assessment of canine TGA was performed using an enzyme-linked immunosorbent assay. Serum total thyroxine and total triiodothyronine concentrations were measured by radioimmunoassay. Serum FT4 concentration was determined by ED, and also by semi-automated CLIA for human FT4 (FT4h) and veterinary FT4 (FT4v). Canine thyroid stimulating hormone concentration was measured by semi-automated CLIA. Each dog's comprehensive thyroid profile supported a diagnosis of hypothyroidism. For detection of hypothyroidism, sensitivities of CLIA for FT4h and FT4v were 62% (95% CI, 32-85%) and 75% (95% CI, 36-96%), respectively, compared to FT4 by ED. Five of 13 (38%) dogs had FT4h and 2 of 8 (25%) dogs had FT4v concentrations by CLIA that were increased or within the reference range. Percentage of false-negative test results for FT4 by CLIA compared to ED was significantly (P < .0001 for FT4h and P < .001for FT4v) higher than the hypothesized false-negative rate of 0%. Caution should be exercised in screening dogs for hypothyroidism using FT4 measured by CLIA alone. Some (25-38%) TGA-positive hypothyroid dogs had FT4 concentrations determined by CLIA that did not support a diagnosis of hypothyroidism. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  11. Gene expression information improves reliability of receptor status in breast cancer patients

    PubMed Central

    Kenn, Michael; Schlangen, Karin; Castillo-Tong, Dan Cacsire; Singer, Christian F.; Cibena, Michael; Koelbl, Heinz; Schreiner, Wolfgang

    2017-01-01

    Immunohistochemical (IHC) determination of receptor status in breast cancer patients is frequently inaccurate. Since it directs the choice of systemic therapy, it is essential to increase its reliability. We increase the validity of IHC receptor expression by additionally considering gene expression (GE) measurements. Crisp therapeutic decisions are based on IHC estimates, even if they are borderline reliable. We further improve decision quality by a responsibility function, defining a critical domain for gene expression. Refined normalization is devised to file any newly diagnosed patient into existing data bases. Our approach renders receptor estimates more reliable by identifying patients with questionable receptor status. The approach is also more efficient since the rate of conclusive samples is increased. We have curated and evaluated gene expression data, together with clinical information, from 2880 breast cancer patients. Combining IHC with gene expression information yields a method more reliable and also more efficient as compared to common practice up to now. Several types of possibly suboptimal treatment allocations, based on IHC receptor status alone, are enumerated. A ‘therapy allocation check’ identifies patients possibly miss-classified. Estrogen: false negative 8%, false positive 6%. Progesterone: false negative 14%, false positive 11%. HER2: false negative 2%, false positive 50%. Possible implications are discussed. We propose an ‘expression look-up-plot’, allowing for a significant potential to improve the quality of precision medicine. Methods are developed and exemplified here for breast cancer patients, but they may readily be transferred to diagnostic data relevant for therapeutic decisions in other fields of oncology. PMID:29100391

  12. Dye-binding assays for evaluation of the effects of small molecule inhibitors on amyloid (aβ) self-assembly.

    PubMed

    Jameson, Laramie P; Smith, Nicholas W; Dzyuba, Sergei V

    2012-11-21

    Dye-binding assays, such as those utilizing Congo red and thioflavin T, are among the most widely used tools to probe the aggregation of amyloidogenic biomolecules and for the evaluation of small molecule inhibitors of amyloid aggregation and fibrillization. A number of recent reports have indicated that these dye-binding assays could be prone to false positive effects when assessing inhibitors' potential toward Aβ peptides, species involved in Alzheimer's disease. Specifically, this review focuses on the application of thioflavin T for determining the efficiency of small molecule inhibitors of Aβ aggregation and addresses potential reasons that might be associated with the false positive effects in an effort to increase reliability of dye-binding assays.

  13. Dye-Binding Assays for Evaluation of the Effects of Small Molecule Inhibitors on Amyloid (Aβ) Self-Assembly

    PubMed Central

    2012-01-01

    Dye-binding assays, such as those utilizing Congo red and thioflavin T, are among the most widely used tools to probe the aggregation of amyloidogenic biomolecules and for the evaluation of small molecule inhibitors of amyloid aggregation and fibrillization. A number of recent reports have indicated that these dye-binding assays could be prone to false positive effects when assessing inhibitors’ potential toward Aβ peptides, species involved in Alzheimer’s disease. Specifically, this review focuses on the application of thioflavin T for determining the efficiency of small molecule inhibitors of Aβ aggregation and addresses potential reasons that might be associated with the false positive effects in an effort to increase reliability of dye-binding assays. PMID:23173064

  14. Do intestinal parasites interfere with the seroepidemiologic surveillance of Schistosoma mansoni infection?

    PubMed Central

    Alarcón de Noya, B.; Colmenares, C.; Losada, S.; Fermin, Z.; Masroua, G.; Ruiz, L.; Soto, L.; Noya, O.

    1996-01-01

    In view of the known cross-reactivity of sera from patients with intestinal parasites to some Schistosoma mansoni antigens, field work was conducted in an area of Venezuela non-endemic for schistosomiasis using the routine immunoenzymatic assay (ELISA) with soluble egg antigen (SEA). False positive reactions represented 15.3% of the total population as determined by SEA-ELISA. SEA-immunoblotting of the false positive sera indicated that protein fractions of 91 and 80 kDa appear to be responsible for cross-reactivity. Sera from hookworm infected individuals produced a higher frequency and intensity of cross-reaction than other sera. SEA-fractions of 105, 54, 46, 42, 32, 25 and 15 kDa were the most specific. Images Fig. 2 PMID:8666077

  15. Neural network for photoplethysmographic respiratory rate monitoring

    NASA Astrophysics Data System (ADS)

    Johansson, Anders

    2001-10-01

    The photoplethysmographic signal (PPG) includes respiratory components seen as frequency modulation of the heart rate (respiratory sinus arrhythmia, RSA), amplitude modulation of the cardiac pulse, and respiratory induced intensity variations (RIIV) in the PPG baseline. The aim of this study was to evaluate the accuracy of these components in determining respiratory rate, and to combine the components in a neural network for improved accuracy. The primary goal is to design a PPG ventilation monitoring system. PPG signals were recorded from 15 healthy subjects. From these signals, the systolic waveform, diastolic waveform, respiratory sinus arrhythmia, pulse amplitude and RIIV were extracted. By using simple algorithms, the rates of false positive and false negative detection of breaths were calculated for each of the five components in a separate analysis. Furthermore, a simple neural network (NN) was tried out in a combined pattern recognition approach. In the separate analysis, the error rates (sum of false positives and false negatives) ranged from 9.7% (pulse amplitude) to 14.5% (systolic waveform). The corresponding value of the NN analysis was 9.5-9.6%.

  16. Variants and pitfalls on radioiodine scans in pediatric patients with differentiated thyroid carcinoma.

    PubMed

    Mostafa, Mohamed; Vali, Reza; Chan, Jeffrey; Omarkhail, Yusuaf; Shammas, Amer

    2016-10-01

    Potentially false-positive findings on radioiodine scans in children with differentiated thyroid carcinoma can mimic functioning thyroid tissue and functioning thyroid carcinomatous tissue. Such false-positive findings comprise variants and pitfalls that can vary slightly in children as compared with adults. To determine the patterns and frequency of these potential false-positive findings on radioiodine scans in children with differentiated thyroid carcinoma. We reviewed a total of 223 radioiodine scans from 53 pediatric patients (mean age 13.3 years, 37 girls) with differentiated thyroid carcinoma. Focal or regional activity that likely did not represent functioning thyroid tissue or functioning thyroid carcinomatous tissue were categorized as variants or pitfalls. The final diagnosis was confirmed by reviewing the concurrent and follow-up clinical data, correlative ultrasonography, CT scanning, serum thyroglobulin and antithyroglobulin antibody levels. We calculated the frequency of these variants and pitfalls from diagnostic and post-therapy radioiodine scans. The most common variant on the radioiodine scans was the thymic activity (24/223, 10.8%) followed by the cardiac activity (8/223, 3.6%). Salivary contamination and star artifact, caused by prominent thyroid remnant, were the most important observed pitfalls. Variants and pitfalls that mimic functioning thyroid tissue or functioning thyroid carcinomatous tissue on radioiodine scan in children with differentiated thyroid carcinoma are not infrequent, but they decrease in frequency on successive radioiodine scans. Potential false-positive findings can be minimized with proper knowledge of the common variants and pitfalls in children and correlation with clinical, laboratory and imaging data.

  17. Autofluorescence imaging to optimize 5-ALA-induced fluorescence endoscopy of bladder carcinoma.

    PubMed

    Frimberger, D; Zaak, D; Stepp, H; Knüchel, R; Baumgartner, R; Schneede, P; Schmeller, N; Hofstetter, A

    2001-09-01

    To design an optical system for detecting autofluorescence (AF) of bladder tumors and to determine the success of reducing the false-positive rate of 5-aminolevulinic acid-induced fluorescence endoscopy (AFE). AFE provides significantly higher sensitivity in detecting and localizing bladder carcinoma compared with white light endoscopy. The specificity of AFE is equivalent to white light endoscopy, mostly because of the false-positive fluorescence of chronic cystitis lesions. Laser-induced spectral autofluorescence detection is also an efficient method in the diagnosis of bladder carcinoma. Bladder tissue was excited to AF using the D-Light (375 to 440 nm) after regular AFE with detection of fluorescence-positive areas. The optical image was produced using a special RGB camera. Biopsies were taken from AFE-positive areas, the peritumoral edges, and normal bladder mucosa. The AF images of the suspicious areas were compared with the AFE images and the histologic results. A total of 43 biopsies were histologically examined (24 benign and 19 neoplastic). AF imaging showed contrast differences between papillary tumors, flat lesions, and normal mucosa. The combination of AFE with AF raised the specificity of AFE alone from 67% to 88%. AF imaging is possible. The value of the method in reducing the false-positive rate of the highly sensitive AFE needs to be validated with higher numbers. The combination of AF with AFE had a 20% higher specificity than AFE alone in our study.

  18. A Closer Look at Self-Reported Suicide Attempts: False Positives and False Negatives

    ERIC Educational Resources Information Center

    Ploderl, Martin; Kralovec, Karl; Yazdi, Kurosch; Fartacek, Reinhold

    2011-01-01

    The validity of self-reported suicide attempt information is undermined by false positives (e.g., incidences without intent to die), or by unreported suicide attempts, referred to as false negatives. In a sample of 1,385 Austrian adults, we explored the occurrence of false positives and false negatives with detailed, probing questions. Removing…

  19. Clinical outcome of subchromosomal events detected by whole‐genome noninvasive prenatal testing

    PubMed Central

    Helgeson, J.; Wardrop, J.; Boomer, T.; Almasri, E.; Paxton, W. B.; Saldivar, J. S.; Dharajiya, N.; Monroe, T. J.; Farkas, D. H.; Grosu, D. S.

    2015-01-01

    Abstract Objective A novel algorithm to identify fetal microdeletion events in maternal plasma has been developed and used in clinical laboratory‐based noninvasive prenatal testing. We used this approach to identify the subchromosomal events 5pdel, 22q11del, 15qdel, 1p36del, 4pdel, 11qdel, and 8qdel in routine testing. We describe the clinical outcomes of those samples identified with these subchromosomal events. Methods Blood samples from high‐risk pregnant women submitted for noninvasive prenatal testing were analyzed using low coverage whole genome massively parallel sequencing. Sequencing data were analyzed using a novel algorithm to detect trisomies and microdeletions. Results In testing 175 393 samples, 55 subchromosomal deletions were reported. The overall positive predictive value for each subchromosomal aberration ranged from 60% to 100% for cases with diagnostic and clinical follow‐up information. The total false positive rate was 0.0017% for confirmed false positives results; false negative rate and sensitivity were not conclusively determined. Conclusion Noninvasive testing can be expanded into the detection of subchromosomal copy number variations, while maintaining overall high test specificity. In the current setting, our results demonstrate high positive predictive values for testing of rare subchromosomal deletions. © 2015 The Authors. Prenatal Diagnosis published by John Wiley & Sons Ltd. PMID:26088833

  20. 5 CFR 532.303 - Specialized industry.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Specialized industry. 532.303 Section 532... SYSTEMS Determining Rates for Principal Types of Positions § 532.303 Specialized industry. (a)(1) Under the appropriated fund wage system, a “specialized industry” is a Federal activity engaged in the...

  1. 5 CFR 532.303 - Specialized industry.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Specialized industry. 532.303 Section 532... SYSTEMS Determining Rates for Principal Types of Positions § 532.303 Specialized industry. (a)(1) Under the appropriated fund wage system, a “specialized industry” is a Federal activity engaged in the...

  2. 5 CFR 532.303 - Specialized industry.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 1 2013-01-01 2013-01-01 false Specialized industry. 532.303 Section 532... SYSTEMS Determining Rates for Principal Types of Positions § 532.303 Specialized industry. (a)(1) Under the appropriated fund wage system, a “specialized industry” is a Federal activity engaged in the...

  3. 5 CFR 532.303 - Specialized industry.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Specialized industry. 532.303 Section 532... SYSTEMS Determining Rates for Principal Types of Positions § 532.303 Specialized industry. (a)(1) Under the appropriated fund wage system, a “specialized industry” is a Federal activity engaged in the...

  4. Modeling Kepler Transit Light Curves as False Positives: Rejection of Blend Scenarios for Kepler-9, and Validation of Kepler-9 d, a Super-Earth-Size Planet in a Multiple System

    NASA Technical Reports Server (NTRS)

    Torres, Guillermo; Fressin, Francois; Batalha, Natalie M.; Borucki, William J.; Brown, Timothy M.; Bryson, Stephen T.; Buchhave, Lars A.; Charbonneau, David; Ciardi, David R.; Dunham, Edward W.; hide

    2011-01-01

    Light curves from the Kepler Mission contain valuable information on the nature of the phenomena producing the transit-like signals. To assist in exploring the possibility that they are due to an astrophysical false positive we describe a procedure (BLENDER) to model the photometry in terms of a blend rather than a planet orbiting a star. A blend may consist of a background or foreground eclipsing binary (or star-planet pair) whose eclipses are attenuated by the light of the candidate and possibly other stars within the photometric aperture. We apply BLENDER to the case of Kepler-9 (KIC 3323887), a target harboring two previously confirmed Saturn-size planets (Kepler-9 b and Kepler-9 c) showing transit timing variations, and an additional shallower signal with a 1.59 day period suggesting the presence of a super-Earth-size planet. Using BLENDER together with constraints from other follow-up observations we are able to rule out all blends for the two deeper signals and provide independent validation of their planetary nature. For the shallower signal, we rule out a large fraction of the false positives that might mimic the transits. The false alarm rate for remaining blends depends in part (and inversely) on the unknown frequency of small-size planets. Based on several realistic estimates of this frequency, we conclude with very high confidence that this small signal is due to a super-Earth-size planet (Kepler-9 d) in a multiple system, rather than a false positive. The radius is determined to be 1.64(exp)(sub-14),R, and current spectroscopic observations are as yet insufficient to establish its mass.

  5. "False Positive" Claims of Near-Death Experiences and "False Negative" Denials of Near-Death Experiences

    ERIC Educational Resources Information Center

    Greyson, Bruce

    2005-01-01

    Some persons who claim to have had near-death experiences (NDEs) fail research criteria for having had NDEs ("false positives"); others who deny having had NDEs do meet research criteria for having had NDEs ("false negatives"). The author evaluated false positive claims and false negative denials in an organization that promotes near-death…

  6. Control/display trade-off study for single-pilot instrument flight rule operations

    NASA Technical Reports Server (NTRS)

    Hoh, R.

    1983-01-01

    The objectives were to determine minimum autopilot functions and displays required to keep pilot workload at an acceptable level; to determine what constitutes an acceptable level of workload; to identify critical tasks; and to suggest specific experiments required to refine conclusions. It was determined that workload relief is derived from basic stability augmentation; that complex autopilots can lead to serious blunders; and that displays need to enhance positional awareness and minimize the likelihood of false hypothesis.

  7. Risk of breast cancer after false-positive results in mammographic screening.

    PubMed

    Román, Marta; Castells, Xavier; Hofvind, Solveig; von Euler-Chelpin, My

    2016-06-01

    Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level data from the population-based screening programs in Copenhagen and Funen in Denmark, Norway, and Spain. Overall, 150,383 screened women from Denmark (1991-2008), 612,138 from Norway (1996-2010), and 1,172,572 from Spain (1990-2006) were included. Poisson regression was used to estimate the relative risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50-69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1.4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93-2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77-1.96), whereas those who tested false-positive at third screening had a RR of 2.42 (95% CI: 2.21-2.64). The RR of breast cancer at the screening test after the false-positive result was 3.95 (95% CI: 3.71-4.21), whereas it decreased to 1.25 (95% CI: 1.17-1.34) three or more screens after the false-positive result. Women with false-positive results had a twofold risk of screen-detected breast cancer compared to women with negative tests. The risk remained significantly higher three or more screens after the false-positive result. The increased risk should be considered when discussing stratified screening strategies. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  8. Determination of cellulose crystallinity from powder diffraction diagrams: Powder Diffraction Diagrams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindner, Benjamin; Petridis, Loukas; Langan, Paul

    2014-10-01

    Commonly one-dimensional (1D) (spherically averaged) powder diffraction diagrams are used to determine the degree of cellulose crystallinity in biomass samples. Here, it is shown using molecular modeling how disorder in cellulose fibrils can lead to considerable uncertainty in conclusions drawn concerning crystallinity based on 1D powder diffraction data alone. For example, cellulose microfibrils that contain both crystalline and noncrystalline segments can lead to powder diffraction diagrams lacking identifiable peaks, while microfibrils without any crystalline segments can lead to such peaks. Moreover, this leads to false positives, that is, assigning disordered cellulose as crystalline, and false negatives, that is, categorizing fibrilsmore » with crystalline segments as amorphous. Finally, the reliable determination of the fraction of crystallinity in any given biomass sample will require a more sophisticated approach combining detailed experiment and simulation.« less

  9. 10 CFR 435.8 - Life-cycle costing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Life-cycle costing. 435.8 Section 435.8 Energy DEPARTMENT...-cycle costing. Each Federal agency shall determine life-cycle cost-effectiveness by using the procedures..., including lower life-cycle costs, positive net savings, savings-to-investment ratio that is estimated to be...

  10. 10 CFR 435.8 - Life-cycle costing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Life-cycle costing. 435.8 Section 435.8 Energy DEPARTMENT...-cycle costing. Each Federal agency shall determine life-cycle cost-effectiveness by using the procedures..., including lower life-cycle costs, positive net savings, savings-to-investment ratio that is estimated to be...

  11. 10 CFR 435.8 - Life-cycle costing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Life-cycle costing. 435.8 Section 435.8 Energy DEPARTMENT...-cycle costing. Each Federal agency shall determine life-cycle cost-effectiveness by using the procedures..., including lower life-cycle costs, positive net savings, savings-to-investment ratio that is estimated to be...

  12. 31 CFR 128.13 - Special survey reports.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance: Treasury 1 2014-07-01 2014-07-01 false Special survey reports. 128.13... Reports on International Capital Transactions and Positions § 128.13 Special survey reports. The Secretary may prescribe special survey reports at such times as the Secretary determines there is a need for...

  13. 5 CFR 532.315 - Additional survey jobs.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Additional survey jobs. 532.315 Section... RATE SYSTEMS Determining Rates for Principal Types of Positions § 532.315 Additional survey jobs. (a) For appropriated fund surveys, when the lead agency adds to the industries to be surveyed, it shall...

  14. 5 CFR 532.315 - Additional survey jobs.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Additional survey jobs. 532.315 Section... RATE SYSTEMS Determining Rates for Principal Types of Positions § 532.315 Additional survey jobs. (a) For appropriated fund surveys, when the lead agency adds to the industries to be surveyed, it shall...

  15. 31 CFR 128.13 - Special survey reports.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance: Treasury 1 2012-07-01 2012-07-01 false Special survey reports. 128.13... Reports on International Capital Transactions and Positions § 128.13 Special survey reports. The Secretary may prescribe special survey reports at such times as the Secretary determines there is a need for...

  16. 5 CFR 532.315 - Additional survey jobs.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Additional survey jobs. 532.315 Section... RATE SYSTEMS Determining Rates for Principal Types of Positions § 532.315 Additional survey jobs. (a) For appropriated fund surveys, when the lead agency adds to the industries to be surveyed, it shall...

  17. 31 CFR 128.13 - Special survey reports.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance: Treasury 1 2013-07-01 2013-07-01 false Special survey reports. 128.13... Reports on International Capital Transactions and Positions § 128.13 Special survey reports. The Secretary may prescribe special survey reports at such times as the Secretary determines there is a need for...

  18. 5 CFR 532.315 - Additional survey jobs.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Additional survey jobs. 532.315 Section... RATE SYSTEMS Determining Rates for Principal Types of Positions § 532.315 Additional survey jobs. (a) For appropriated fund surveys, when the lead agency adds to the industries to be surveyed, it shall...

  19. 31 CFR 128.13 - Special survey reports.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance: Treasury 1 2011-07-01 2011-07-01 false Special survey reports. 128.13... Reports on International Capital Transactions and Positions § 128.13 Special survey reports. The Secretary may prescribe special survey reports at such times as the Secretary determines there is a need for...

  20. 14 CFR 25.1531 - Maneuvering flight load factors.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Maneuvering flight load factors. 25.1531... Operating Limitations § 25.1531 Maneuvering flight load factors. Load factor limitations, not exceeding the positive limit load factors determined from the maneuvering diagram in § 25.333(b), must be established. ...

  1. 16 CFR 1203.14 - Peripheral vision test.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Peripheral vision test. 1203.14 Section 1203... SAFETY STANDARD FOR BICYCLE HELMETS The Standard § 1203.14 Peripheral vision test. Position the helmet on... the helmet to set the comfort or fit padding. (Note: Peripheral vision clearance may be determined...

  2. 16 CFR 1203.14 - Peripheral vision test.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Peripheral vision test. 1203.14 Section 1203... SAFETY STANDARD FOR BICYCLE HELMETS The Standard § 1203.14 Peripheral vision test. Position the helmet on... the helmet to set the comfort or fit padding. (Note: Peripheral vision clearance may be determined...

  3. 5 CFR 532.305 - Dominant industry.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 5 Administrative Personnel 1 2011-01-01 2011-01-01 false Dominant industry. 532.305 Section 532... SYSTEMS Determining Rates for Principal Types of Positions § 532.305 Dominant industry. (a)(1) A specialized industry is a “dominant industry” if the number of wage employees in the wage area who are subject...

  4. 5 CFR 532.305 - Dominant industry.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Dominant industry. 532.305 Section 532... SYSTEMS Determining Rates for Principal Types of Positions § 532.305 Dominant industry. (a)(1) A specialized industry is a “dominant industry” if the number of wage employees in the wage area who are subject...

  5. 5 CFR 532.305 - Dominant industry.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Dominant industry. 532.305 Section 532... SYSTEMS Determining Rates for Principal Types of Positions § 532.305 Dominant industry. (a)(1) A specialized industry is a “dominant industry” if the number of wage employees in the wage area who are subject...

  6. 5 CFR 532.305 - Dominant industry.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 5 Administrative Personnel 1 2013-01-01 2013-01-01 false Dominant industry. 532.305 Section 532... SYSTEMS Determining Rates for Principal Types of Positions § 532.305 Dominant industry. (a)(1) A specialized industry is a “dominant industry” if the number of wage employees in the wage area who are subject...

  7. 47 CFR 80.320 - Radiotelephone distress call and message transmission procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... by its call sign or name, to permit direction-finding stations to determine its position. This... 47 Telecommunication 5 2010-10-01 2010-10-01 false Radiotelephone distress call and message... Procedures Distress, Alarm, Urgency and Safety Procedures § 80.320 Radiotelephone distress call and message...

  8. 5 CFR 532.407 - Promotion.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Promotion. 532.407 Section 532.407... Administration § 532.407 Promotion. (a) An employee who is promoted is entitled to be paid at the lowest.... (c) If the promotion is to a position in a different wage area, the agency shall determine the...

  9. Reduction of false-positive recalls using a computerized mammographic image feature analysis scheme

    NASA Astrophysics Data System (ADS)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-08-01

    The high false-positive recall rate is one of the major dilemmas that significantly reduce the efficacy of screening mammography, which harms a large fraction of women and increases healthcare cost. This study aims to investigate the feasibility of helping reduce false-positive recalls by developing a new computer-aided diagnosis (CAD) scheme based on the analysis of global mammographic texture and density features computed from four-view images. Our database includes full-field digital mammography (FFDM) images acquired from 1052 recalled women (669 positive for cancer and 383 benign). Each case has four images: two craniocaudal (CC) and two mediolateral oblique (MLO) views. Our CAD scheme first computed global texture features related to the mammographic density distribution on the segmented breast regions of four images. Second, the computed features were given to two artificial neural network (ANN) classifiers that were separately trained and tested in a ten-fold cross-validation scheme on CC and MLO view images, respectively. Finally, two ANN classification scores were combined using a new adaptive scoring fusion method that automatically determined the optimal weights to assign to both views. CAD performance was tested using the area under a receiver operating characteristic curve (AUC). The AUC = 0.793  ±  0.026 was obtained for this four-view CAD scheme, which was significantly higher at the 5% significance level than the AUCs achieved when using only CC (p = 0.025) or MLO (p = 0.0004) view images, respectively. This study demonstrates that a quantitative assessment of global mammographic image texture and density features could provide useful and/or supplementary information to classify between malignant and benign cases among the recalled cases, which may eventually help reduce the false-positive recall rate in screening mammography.

  10. Rubella Surveillance and Diagnostic Testing among a Low-Prevalence Population, New York City, 2012-2013.

    PubMed

    Isaac, Beth M; Zucker, Jane R; Giancotti, Francesca R; Abernathy, Emily; Icenogle, Joseph; Rakeman, Jennifer L; Rosen, Jennifer B

    2017-09-01

    The New York City Department of Health and Mental Hygiene (DOHMH) receives clinical and laboratory reports for rubella. Because rubella immunoglobulin M (IgM) assays may produce false-positive results and rubella infections may be asymptomatic, interpretation of positive IgM results can be challenging. Rubella reports received by DOHMH in 2012 to 2013 were reviewed. The rubella IgM testing purpose was determined through case investigation. Results of IgM testing by indirect enzyme-linked immunosorbent assay (ELISA) and capture enzyme immunoassay (EIA) were compared to determine positive predictive value (PPV) and specificity. DOHMH received 199 rubella reports; 2 were true cases. Of all reports, 77.9% were tested for rubella IgM erroneously, 19.6% were tested for diagnostic purposes, 2.0% had unknown test purpose, and 0.5% were not tested. PPV of indirect ELISA was 6% overall, 14% for diagnostic tests, and 0% for tests ordered erroneously. PPV of capture EIA was 29% overall, 50% for diagnostic tests, and 0% for tests ordered erroneously. Overall, specificity was 52% for indirect ELISA and 85% for capture EIA. Limiting rubella IgM testing to patients for whom rubella diagnosis is suspected and using a more specific IgM assay have the potential to reduce false-positive rubella IgM results. Copyright © 2017 American Society for Microbiology.

  11. Characterisation of false-positive observations in botanical surveys

    PubMed Central

    2017-01-01

    Errors in botanical surveying are a common problem. The presence of a species is easily overlooked, leading to false-absences; while misidentifications and other mistakes lead to false-positive observations. While it is common knowledge that these errors occur, there are few data that can be used to quantify and describe these errors. Here we characterise false-positive errors for a controlled set of surveys conducted as part of a field identification test of botanical skill. Surveys were conducted at sites with a verified list of vascular plant species. The candidates were asked to list all the species they could identify in a defined botanically rich area. They were told beforehand that their final score would be the sum of the correct species they listed, but false-positive errors counted against their overall grade. The number of errors varied considerably between people, some people create a high proportion of false-positive errors, but these are scattered across all skill levels. Therefore, a person’s ability to correctly identify a large number of species is not a safeguard against the generation of false-positive errors. There was no phylogenetic pattern to falsely observed species; however, rare species are more likely to be false-positive as are species from species rich genera. Raising the threshold for the acceptance of an observation reduced false-positive observations dramatically, but at the expense of more false negative errors. False-positive errors are higher in field surveying of plants than many people may appreciate. Greater stringency is required before accepting species as present at a site, particularly for rare species. Combining multiple surveys resolves the problem, but requires a considerable increase in effort to achieve the same sensitivity as a single survey. Therefore, other methods should be used to raise the threshold for the acceptance of a species. For example, digital data input systems that can verify, feedback and inform the user are likely to reduce false-positive errors significantly. PMID:28533972

  12. Assessing environmental DNA detection in controlled lentic systems.

    PubMed

    Moyer, Gregory R; Díaz-Ferguson, Edgardo; Hill, Jeffrey E; Shea, Colin

    2014-01-01

    Little consideration has been given to environmental DNA (eDNA) sampling strategies for rare species. The certainty of species detection relies on understanding false positive and false negative error rates. We used artificial ponds together with logistic regression models to assess the detection of African jewelfish eDNA at varying fish densities (0, 0.32, 1.75, and 5.25 fish/m3). Our objectives were to determine the most effective water stratum for eDNA detection, estimate true and false positive eDNA detection rates, and assess the number of water samples necessary to minimize the risk of false negatives. There were 28 eDNA detections in 324, 1-L, water samples collected from four experimental ponds. The best-approximating model indicated that the per-L-sample probability of eDNA detection was 4.86 times more likely for every 2.53 fish/m3 (1 SD) increase in fish density and 1.67 times less likely for every 1.02 C (1 SD) increase in water temperature. The best section of the water column to detect eDNA was the surface and to a lesser extent the bottom. Although no false positives were detected, the estimated likely number of false positives in samples from ponds that contained fish averaged 3.62. At high densities of African jewelfish, 3-5 L of water provided a >95% probability for the presence/absence of its eDNA. Conversely, at moderate and low densities, the number of water samples necessary to achieve a >95% probability of eDNA detection approximated 42-73 and >100 L, respectively. Potential biases associated with incomplete detection of eDNA could be alleviated via formal estimation of eDNA detection probabilities under an occupancy modeling framework; alternatively, the filtration of hundreds of liters of water may be required to achieve a high (e.g., 95%) level of certainty that African jewelfish eDNA will be detected at low densities (i.e., <0.32 fish/m3 or 1.75 g/m3).

  13. Enhancing pediatric clinical trial feasibility through the use of Bayesian statistics.

    PubMed

    Huff, Robin A; Maca, Jeff D; Puri, Mala; Seltzer, Earl W

    2017-11-01

    BackgroundPediatric clinical trials commonly experience recruitment challenges including limited number of patients and investigators, inclusion/exclusion criteria that further reduce the patient pool, and a competitive research landscape created by pediatric regulatory commitments. To overcome these challenges, innovative approaches are needed.MethodsThis article explores the use of Bayesian statistics to improve pediatric trial feasibility, using pediatric Type-2 diabetes as an example. Data for six therapies approved for adults were used to perform simulations to determine the impact on pediatric trial size.ResultsWhen the number of adult patients contributing to the simulation was assumed to be the same as the number of patients to be enrolled in the pediatric trial, the pediatric trial size was reduced by 75-78% when compared with a frequentist statistical approach, but was associated with a 34-45% false-positive rate. In subsequent simulations, greater control was exerted over the false-positive rate by decreasing the contribution of the adult data. A 30-33% reduction in trial size was achieved when false-positives were held to less than 10%.ConclusionReducing the trial size through the use of Bayesian statistics would facilitate completion of pediatric trials, enabling drugs to be labeled appropriately for children.

  14. Kepler Certified False Positive Table

    NASA Technical Reports Server (NTRS)

    Bryson, Stephen T.; Batalha, Natalie Marie; Colon, Knicole Dawn; Coughlin, Jeffrey Langer; Haas, Michael R.; Henze, Chris; Huber, Daniel; Morton, Tim; Rowe, Jason Frank; Mullally, Susan Elizabeth; hide

    2017-01-01

    This document describes the Kepler Certied False Positive table hosted at the Exoplanet Archive1, herein referred to as the CFP table. This table is the result of detailed examination by the Kepler False Positive Working Group (FPWG) of declared false positives in the Kepler Object of Interest (KOI) tables (see, for example, Batalha et al. (2012); Burke et al.(2014); Rowe et al. (2015); Mullally et al. (2015); Coughlin et al. (2015b)) at the Exoplanet Archive. A KOI is considered a false positive if it is not due to a planet orbiting the KOI's target star. The CFP table contains all KOIs in the Exoplanet Archive cumulative KOI table. The purpose of the CFP table is to provide a list of certified false positive KOIs. A KOI is certified as a false positive when, in the judgement of the FPWG, there is no plausible planetary interpretation of the observational evidence, which we summarize by saying that the evidence for a false positive is compelling. This certification process involves detailed examination using all available data for each KOI, establishing a high-reliability ground truth set. The CFP table can be used to estimate the reliability of, for example, the KOI tables which are created using only Kepler photometric data, so the disposition of individual KOIs may differ in the KOI and CFP tables. Follow-up observers may find the CFP table useful to avoid observing false positives.

  15. Cumulative risk of false positive test in relation to breast symptoms in mammography screening: a historical prospective cohort study.

    PubMed

    Singh, Deependra; Pitkäniemi, Janne; Malila, Nea; Anttila, Ahti

    2016-09-01

    Mammography has been found effective as the primary screening test for breast cancer. We estimated the cumulative probability of false positive screening test results with respect to symptom history reported at screen. A historical prospective cohort study was done using individual screening data from 413,611 women aged 50-69 years with 2,627,256 invitations for mammography screening between 1992 and 2012 in Finland. Symptoms (lump, retraction, and secretion) were reported at 56,805 visits, and 48,873 visits resulted in a false positive mammography result. Generalized linear models were used to estimate the probability of at least one false positive test and true positive at screening visits. The estimates were compared among women with and without symptoms history. The estimated cumulative probabilities were 18 and 6 % for false positive and true positive results, respectively. In women with a history of a lump, the cumulative probabilities of false positive test and true positive were 45 and 16 %, respectively, compared to 17 and 5 % with no reported lump. In women with a history of any given symptom, the cumulative probabilities of false positive test and true positive were 38 and 13 %, respectively. Likewise, women with a history of a 'lump and retraction' had the cumulative false positive probability of 56 %. The study showed higher cumulative risk of false positive tests and more cancers detected in women who reported symptoms compared to women who did not report symptoms at screen. The risk varies substantially, depending on symptom types and characteristics. Information on breast symptoms influences the balance of absolute benefits and harms of screening.

  16. Detecting false positives in multielement designs: implications for brief assessments.

    PubMed

    Bartlett, Sara M; Rapp, John T; Henrickson, Marissa L

    2011-11-01

    The authors assessed the extent to which multielement designs produced false positives using continuous duration recording (CDR) and interval recording with 10-s and 1-min interval sizes. Specifically, they created 6,000 graphs with multielement designs that varied in the number of data paths, and the number of data points per data path, using a random number generator. In Experiment 1, the authors visually analyzed the graphs for the occurrence of false positives. Results indicated that graphs depicting only two sessions for each condition (e.g., a control condition plotted with multiple test conditions) produced the highest percentage of false positives for CDR and interval recording with 10-s and 1-min intervals. Conversely, graphs with four or five sessions for each condition produced the lowest percentage of false positives for each method. In Experiment 2, they applied two new rules, which were intended to decrease false positives, to each graph that depicted a false positive in Experiment 1. Results showed that application of new rules decreased false positives to less than 5% for all of the graphs except for those with two data paths and two data points per data path. Implications for brief assessments are discussed.

  17. Response time as a discriminator between true- and false-positive responses in suprathreshold perimetry.

    PubMed

    Artes, Paul H; McLeod, David; Henson, David B

    2002-01-01

    To report on differences between the latency distributions of responses to stimuli and to false-positive catch trials in suprathreshold perimetry. To describe an algorithm for defining response time windows and to report on its performance in discriminating between true- and false-positive responses on the basis of response time (RT). A sample of 435 largely inexperienced patients underwent suprathreshold visual field examination on a perimeter that was modified to record RTs. Data were analyzed from 60,500 responses to suprathreshold stimuli and from 523 false-positive responses to catch trials. False-positive responses had much more variable latencies than responses to suprathreshold stimuli. An algorithm defining RT windows on the basis of z-transformed individual latency samples correctly identified more than 70% of false-positive responses to catch trials, whereas fewer than 3% of responses to suprathreshold stimuli were classified as false-positive responses. Latency analysis can be used to detect a substantial proportion of false-positive responses in suprathreshold perimetry. Rejection of such responses may increase the reliability of visual field screening by reducing variability and bias in a small but clinically important proportion of patients.

  18. Validation of an Arab names algorithm in the determination of Arab ancestry for use in health research

    PubMed Central

    El-Sayed, Abdulrahman M.; Lauderdale, Diane S.; Galea, Sandro

    2010-01-01

    Objective Data about Arab-Americans, a growing ethnic minority, is not routinely collected in vital statistics, registry, or administrative data in the US. The difficulty in identifying Arab-Americans using publicly available data sources is a barrier to health research about this group. Here, we validate an empirically-based, probabilistic Arab name algorithm (ANA) for identifying Arab-Americans in health research. Design We used data from all Michigan birth certificates between 2000-2005. Fathers’ surnames and mothers’ maiden names were coded as Arab or non-Arab according to the ANA. We calculated sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) of Arab ethnicity inferred using the ANA as compared to self-reported Arab ancestry. Results State-wide, the ANA had a specificity of 98.9%, a sensitivity of 50.3%, a PPV of 57.0%, and a NPV of 98.6%. Both the false positive and false negative rates were higher among men than among women. As the concentration of Arab-Americans in a study locality increased, the ANA false positive rate increased and false-negative rate decreased. Conclusion The ANA is highly specific but only moderately sensitive as a means of detecting Arab ancestry. Future research should compare health characteristics among Arab-American populations defined by Arab ancestry and those defined by the ANA. PMID:20845117

  19. A stochastic model to determine the economic value of changing diagnostic test characteristics for identification of cattle for treatment of bovine respiratory disease.

    PubMed

    Theurer, M E; White, B J; Larson, R L; Schroeder, T C

    2015-03-01

    Bovine respiratory disease is an economically important syndrome in the beef industry, and diagnostic accuracy is important for optimal disease management. The objective of this study was to determine whether improving diagnostic sensitivity or specificity was of greater economic value at varied levels of respiratory disease prevalence by using Monte Carlo simulation. Existing literature was used to populate model distributions of published sensitivity, specificity, and performance (ADG, carcass weight, yield grade, quality grade, and mortality risk) differences among calves based on clinical respiratory disease status. Data from multiple cattle feeding operations were used to generate true ranges of respiratory disease prevalence and associated mortality. Input variables were combined into a single model that calculated estimated net returns for animals by diagnostic category (true positive, false positive, false negative, and true negative) based on the prevalence, sensitivity, and specificity for each iteration. Net returns for each diagnostic category were multiplied by the proportion of animals in each diagnostic category to determine group profitability. Apparent prevalence was categorized into low (<15%) and high (≥15%) groups. For both apparent prevalence categories, increasing specificity created more rapid, positive change in net returns than increasing sensitivity. Improvement of diagnostic specificity, perhaps through a confirmatory test interpreted in series or pen-level diagnostics, can increase diagnostic value more than improving sensitivity. Mortality risk was the primary driver for net returns. The results from this study are important for determining future research priorities to analyze diagnostic techniques for bovine respiratory disease and provide a novel way for modeling diagnostic tests.

  20. The human false-negative rate of rescreening Pap tests. Measured in a two-arm prospective clinical trial.

    PubMed

    Renshaw, A A; Lezon, K M; Wilbur, D C

    2001-04-25

    Routine quality control rescreening often is used to calculate the false-negative rate (FNR) of gynecologic cytology. Theoretic analysis suggests that this is not appropriate, due to the high FNR of rescreening and the inability to actually measure it. The authors sought to determine the FNR of manual rescreening in a large, prospective, two-arm clinical trial using an analytic instrument in the evaluation. The results of the Autopap System Clinical Trial, encompassing 25,124 analyzed slides, were reviewed. The false-negative and false-positive rates at various thresholds were determined for routine primary screening, routine rescreening, Autopap primary screening, and Autopap rescreening by using a simple, standard methodology. The FNR of routine manual rescreening at the level of atypical squamous cells of undetermined significance (ASCUS) was 73%, more than 3 times the FNR of primary screening; 11 cases were detected. The FNR of Autopap rescreening was 34%; 80 cases were detected. Routine manual rescreening decreased the laboratory FNR by less than 1%; Autopap rescreening reduced the overall laboratory FNR by 5.7%. At the same time, the false-positive rate for Autopap screening was significantly less than that of routine manual screening at the ASCUS level (4.7% vs. 5.6%; P < 0.0001). Rescreening with the Autopap system remained more sensitive than manual rescreening at the low grade squamous intraepithelial lesions threshold (FNR of 58.8% vs. 100%, respectively), although the number of cases rescreened was low. Routine manual rescreening cannot be used to calculate the FNR of primary screening. Routine rescreening is an extremely ineffective method to detect error and thereby decrease a laboratory's FNR. The Autopap system is a much more effective way of detecting errors within a laboratory and reduces the laboratory's FNR by greater than 25%.

  1. False negative rates in Drosophila cell-based RNAi screens: a case study

    PubMed Central

    2011-01-01

    Background High-throughput screening using RNAi is a powerful gene discovery method but is often complicated by false positive and false negative results. Whereas false positive results associated with RNAi reagents has been a matter of extensive study, the issue of false negatives has received less attention. Results We performed a meta-analysis of several genome-wide, cell-based Drosophila RNAi screens, together with a more focused RNAi screen, and conclude that the rate of false negative results is at least 8%. Further, we demonstrate how knowledge of the cell transcriptome can be used to resolve ambiguous results and how the number of false negative results can be reduced by using multiple, independently-tested RNAi reagents per gene. Conclusions RNAi reagents that target the same gene do not always yield consistent results due to false positives and weak or ineffective reagents. False positive results can be partially minimized by filtering with transcriptome data. RNAi libraries with multiple reagents per gene also reduce false positive and false negative outcomes when inconsistent results are disambiguated carefully. PMID:21251254

  2. [Roaming through methodology. XXXII. False test results].

    PubMed

    van der Weijden, T; van den Akker, M

    2001-05-12

    The number of requests for diagnostic tests is rising. This leads to a higher chance of false test results. The false-negative proportion of a test is the proportion of negative test results among the diseased subjects. The false-positive proportion is the proportion of positive test results among the healthy subjects. The calculation of the false-positive proportion is often incorrect. For example, instead of 1 minus the specificity it is calculated as 1 minus the positive predictive value. This can lead to incorrect decision-making with respect to the application of the test. Physicians must apply diagnostic tests in such a way that the risk of false test results is minimal. The patient should be aware that a perfectly conclusive diagnostic test is rare in medical practice, and should more often be informed of the implications of false-positive and false-negative test results.

  3. False positive acetaminophen concentrations in patients with liver injury.

    PubMed

    Polson, Julie; Wians, Frank H; Orsulak, Paul; Fuller, Dwain; Murray, Natalie G; Koff, Jonathan M; Khan, Adil I; Balko, Jody A; Hynan, Linda S; Lee, William M

    2008-05-01

    Acetaminophen toxicity is the most common form of acute liver failure in the U.S. After acetaminophen overdoses, quantitation of plasma acetaminophen can aid in predicting severity of injury. However, recent case reports have suggested that acetaminophen concentrations may be falsely increased in the presence of hyperbilirubinemia. We tested sera obtained from 43 patients with acute liver failure, mostly unrelated to acetaminophen, utilizing 6 different acetaminophen quantitation systems to determine the significance of this effect. In 36 of the 43 samples with bilirubin concentrations ranging from 1.0-61.5 mg/dl no acetaminophen was detectable by gas chromatography-mass spectroscopy. These 36 samples were then utilized to test the performance characteristics of 2 immunoassay and 4 enzymatic-colorimetric methods. Three of four colorimetric methods demonstrated 'detectable' values for acetaminophen in from 4 to 27 of the 36 negative samples, low concentration positive values being observed when serum bilirubin concentrations exceeded 10 mg/dl. By contrast, the 2 immunoassay methods (EMIT, FPIA) were virtually unaffected. The false positive values obtained were, in general, proportional to the quantity of bilirubin in the sample. However, prepared samples of normal human serum with added bilirubin showed a dose-response curve for only one of the 4 colorimetric assays. False positive acetaminophen tests may result when enzymatic-colorimetric assays are used, most commonly with bilirubin concentrations >10 mg/dl, leading to potential clinical errors in this setting. Bilirubin (or possibly other substances in acute liver failure sera) appears to affect the reliable measurement of acetaminophen, particularly with enzymatic-colorimetric assays.

  4. Correcting false positive medium-chain acyl-CoA dehydrogenase deficiency results from newborn screening; synthesis, purification, and standardization of branched-chain C8 acylcarnitines for use in their selective and accurate absolute quantitation by UHPLC-MS/MS.

    PubMed

    Minkler, Paul E; Stoll, Maria S K; Ingalls, Stephen T; Hoppel, Charles L

    2017-04-01

    While selectively quantifying acylcarnitines in thousands of patient samples using UHPLC-MS/MS, we have occasionally observed unidentified branched-chain C8 acylcarnitines. Such observations are not possible using tandem MS methods, which generate pseudo-quantitative acylcarnitine "profiles". Since these "profiles" select for mass alone, they cannot distinguish authentic signal from isobaric and isomeric interferences. For example, some of the samples containing branched-chain C8 acylcarnitines were, in fact, expanded newborn screening false positive "profiles" for medium-chain acyl-CoA dehydrogenase deficiency (MCADD). Using our fast, highly selective, and quantitatively accurate UHPLC-MS/MS acylcarnitine determination method, we corrected the false positive tandem MS results and reported the sample results as normal for octanoylcarnitine (the marker for MCADD). From instances such as these, we decided to further investigate the presence of branched-chain C8 acylcarnitines in patient samples. To accomplish this, we synthesized and chromatographically characterized several branched-chain C8 acylcarnitines (in addition to valproylcarnitine): 2-methylheptanoylcarnitine, 6-methylheptanoylcarnitine, 2,2-dimethylhexanoylcarnitine, 3,3-dimethylhexanoylcarnitine, 3,5-dimethylhexanoylcarnitine, 2-ethylhexanoylcarnitine, and 2,4,4-trimethylpentanoylcarnitine. We then compared their behavior with branched-chain C8 acylcarnitines observed in patient samples and demonstrated our ability to chromographically resolve, and thus distinguish, octanoylcarnitine from branched-chain C8 acylcarnitines, correcting false positive MCADD results from expanded newborn screening. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Accurate decisions in an uncertain world: collective cognition increases true positives while decreasing false positives.

    PubMed

    Wolf, Max; Kurvers, Ralf H J M; Ward, Ashley J W; Krause, Stefan; Krause, Jens

    2013-04-07

    In a wide range of contexts, including predator avoidance, medical decision-making and security screening, decision accuracy is fundamentally constrained by the trade-off between true and false positives. Increased true positives are possible only at the cost of increased false positives; conversely, decreased false positives are associated with decreased true positives. We use an integrated theoretical and experimental approach to show that a group of decision-makers can overcome this basic limitation. Using a mathematical model, we show that a simple quorum decision rule enables individuals in groups to simultaneously increase true positives and decrease false positives. The results from a predator-detection experiment that we performed with humans are in line with these predictions: (i) after observing the choices of the other group members, individuals both increase true positives and decrease false positives, (ii) this effect gets stronger as group size increases, (iii) individuals use a quorum threshold set between the average true- and false-positive rates of the other group members, and (iv) individuals adjust their quorum adaptively to the performance of the group. Our results have broad implications for our understanding of the ecology and evolution of group-living animals and lend themselves for applications in the human domain such as the design of improved screening methods in medical, forensic, security and business applications.

  6. Accurate decisions in an uncertain world: collective cognition increases true positives while decreasing false positives

    PubMed Central

    Wolf, Max; Kurvers, Ralf H. J. M.; Ward, Ashley J. W.; Krause, Stefan; Krause, Jens

    2013-01-01

    In a wide range of contexts, including predator avoidance, medical decision-making and security screening, decision accuracy is fundamentally constrained by the trade-off between true and false positives. Increased true positives are possible only at the cost of increased false positives; conversely, decreased false positives are associated with decreased true positives. We use an integrated theoretical and experimental approach to show that a group of decision-makers can overcome this basic limitation. Using a mathematical model, we show that a simple quorum decision rule enables individuals in groups to simultaneously increase true positives and decrease false positives. The results from a predator-detection experiment that we performed with humans are in line with these predictions: (i) after observing the choices of the other group members, individuals both increase true positives and decrease false positives, (ii) this effect gets stronger as group size increases, (iii) individuals use a quorum threshold set between the average true- and false-positive rates of the other group members, and (iv) individuals adjust their quorum adaptively to the performance of the group. Our results have broad implications for our understanding of the ecology and evolution of group-living animals and lend themselves for applications in the human domain such as the design of improved screening methods in medical, forensic, security and business applications. PMID:23407830

  7. Screening for Sex Chromosome Aneuploidy by Cell-Free DNA Testing: Patient Choice and Performance.

    PubMed

    Bevilacqua, Elisa; Ordóñez, Elena; Hurtado, Ivan; Rueda, Laura; Mazzone, Eléonora; Cirigliano, Vincenzo; Jani, Jacques C

    2017-08-23

    To study patient choice regarding testing for sex chromosome aneuploidy (SCA) and the performance of cell-free DNA (cfDNA) screening for SCA. Patient choice regarding screening for SCA and factors influencing this choice were evaluated in a single center. In a subsequent two-center study, cases that screened positive for SCA were analyzed to determine the positive predictive value (PPV) for each SCA. In all, 1,957 (61.9%) of the 3,162 patients undergoing cfDNA testing opted for SCA screening. Regression analysis demonstrated that independent predictors of a patient's decision for SCA were earlier gestational age, spontaneous conception, and cfDNA chosen as a primary method of screening. A total of 161 cases screened positive for SCA and follow-up data were available for 118 (73.3%). Forty-six of the 61 cases of 45,X were false-positive results and 15 were concordant with the fetal karyotype (PPV = 24.6%). Seventeen of the 22 cases of 47,XXX were false positive and 5 concordant (PPV = 22.7%). Eleven of the 30 cases of 47,XXY were false positive and 19 concordant (PPV = 63.3%). All 5 cases of 47,XYY were correctly identified, thus yielding a PPV of 100%. More than half of the patients undergoing cfDNA aneuploidy screening also opted for SCA testing, but they were less likely to do so in the presence of an increased risk of trisomy. SCAs involving the X chromosome had a lower PPV than those involving the Y chromosome. © 2017 S. Karger AG, Basel.

  8. Categorizing mistaken false positives in regulation of human and environmental health.

    PubMed

    Hansen, Steffen Foss; Krayer von Krauss, Martin P; Tickner, Joel A

    2007-02-01

    One of the concerns often voiced by critics of the precautionary principle is that a widespread regulatory application of the principle will lead to a large number of false positives (i.e., over-regulation of minor risks and regulation of nonexisting risks). The present article proposes a general definition of a regulatory false positive, and seeks to identify case studies that can be considered authentic regulatory false positives. Through a comprehensive review of the science policy literature for proclaimed false positives and interviews with authorities on regulation and the precautionary principle we identified 88 cases. Following a detailed analysis of these cases, we found that few of the cases mentioned in the literature can be considered to be authentic false positives. As a result, we have developed a number of different categories for these cases of "mistaken false positives," including: real risks, "The jury is still out," nonregulated proclaimed risks, "Too narrow a definition of risk," and risk-risk tradeoffs. These categories are defined and examples are presented in order to illustrate their key characteristics. On the basis of our analysis, we were able to identify only four cases that could be defined as regulatory false positives in the light of today's knowledge and recognized uncertainty: the Southern Corn Leaf Blight, the Swine Flu, Saccharin, and Food Irradiation in relation to consumer health. We conclude that concerns about false positives do not represent a reasonable argument against future application of the precautionary principle.

  9. An analysis of false positive reactions occurring with the Captia Syph G EIA.

    PubMed Central

    Ross, J; Moyes, A; Young, H; McMillan, A

    1991-01-01

    AIM--The Captia Syph G enzyme immuno assay (EAI) offers the potential for the rapid automated detection of syphilis antibodies. This study was designed to assess the role of other sexually transmitted diseases (STDs) in producing false positive reactions in the Captia Syph G EIA. The role of rheumatoid factor (RF) as a potential source of false positives was also analysed. METHODS--Patients who attended a genitourinary medicine (GUM) department and gave a false positive reaction with the EIA between 1988 and 1990 were compared with women undergoing antenatal testing and with the control clinic population (EIA negative) over the same time period. The incidence of sexually transmitted disease (STD) in the clinic population and the false positive reactors was measured in relation to gonorrhoea, chlamydia, genital warts, candidiasis, "other conditions not requiring treatment" and "other conditions requiring treatment." Male: female sex ratios were also compared. Ninety two RF positive sera were analysed with the EIA. RESULTS--The rate of false positive reactions did not differ with respect to the diagnosis within the GUM clinic population. The antenatal group of women, however, had a lower incidence of false positive reactions than the GUM clinic group. No RF positive sera were positive on Captia Syph G EIA testing. CONCLUSIONS--There is no cross reaction between Captia Syph G EIA and any specific STD or with RF positive sera. The lower incidence of false positive reactions in antenatal women is unexplained but may be related to physiological changes associated with pregnancy. PMID:1743715

  10. Evaluation of EMIT and RIA high volume test procedures for THC metabolites in urine utilizing GC/MS confirmation.

    PubMed

    Abercrombie, M L; Jewell, J S

    1986-01-01

    Results of EMIT, Abuscreen RIA, and GC/MS tests for THC metabolites in a high volume random urinalysis program are compared. Samples were field tested by non-laboratory personnel with an EMIT system using a 100 ng/mL cutoff. Samples were then sent to the Army Forensic Toxicology Drug Testing Laboratory (WRAMC) at Fort Meade, Maryland, where they were tested by RIA (Abuscreen) using a statistical 100 ng/mL cutoff. Confirmations of all RIA positives were accomplished using a GC/MS procedure. EMIT and RIA results agreed for 91% of samples. Data indicated a 4% false positive rate and a 10% false negative rate for EMIT field testing. In a related study, results for samples which tested positive by RIA for THC metabolites using a statistical 100 ng/mL cutoff were compared with results by GC/MS utilizing a 20 ng/mL cutoff for the THCA metabolite. Presence of THCA metabolite was detected in 99.7% of RIA positive samples. No relationship between quantitations determined by the two tests was found.

  11. Verification of clinical samples, positive in AMPLICOR Neisseria gonorrhoeae polymerase chain reaction, by 16S rRNA and gyrA compared with culture.

    PubMed

    Airell, Asa; Lindbäck, Emma; Ataker, Ferda; Pörnull, Kirsti Jalakas; Wretlind, Bengt

    2005-06-01

    We compared 956 samples for AMPLICOR Neisseria gonorrhoeae polymerase chain reaction (PCR) (Roche) with species verification using the 16S rRNA gene to verification using gyrA gene. Control was the culture method. The gyrA verification uses pyrosequencing of the quinolone resistance-determining region of gyrA. Of 52 samples with optical density >/=0.2 in PCR, 27 were negative in culture, two samples from pharynx were false negative in culture and four samples from pharynx were false positives in verification with 16S rRNA. Twenty-five samples showed growth of gonococci, 18 of the corresponding PCR samples were verified by both methods; three urine samples were positive only in gyrA ; and one pharynx specimen was positive only in 16S rRNA. Three samples were lost. We conclude that AMPLICOR N. gonorrhoeae PCR with verification in gyrA gene can be considered as a diagnostic tool in populations with low prevalence of gonorrhoea and that pharynx specimens should not be analysed by PCR.

  12. Automatic Reacquisition of Satellite Positions by Detecting Their Expected Streaks in Astronomical Images

    NASA Astrophysics Data System (ADS)

    Levesque, M.

    Artificial satellites, and particularly space junk, drift continuously from their known orbits. In the surveillance-of-space context, they must be observed frequently to ensure that the corresponding orbital parameter database entries are up-to-date. Autonomous ground-based optical systems are periodically tasked to observe these objects, calculate the difference between their predicted and real positions and update object orbital parameters. The real satellite positions are provided by the detection of the satellite streaks in the astronomical images specifically acquired for this purpose. This paper presents the image processing techniques used to detect and extract the satellite positions. The methodology includes several processing steps including: image background estimation and removal, star detection and removal, an iterative matched filter for streak detection, and finally false alarm rejection algorithms. This detection methodology is able to detect very faint objects. Simulated data were used to evaluate the methodology's performance and determine the sensitivity limits where the algorithm can perform detection without false alarm, which is essential to avoid corruption of the orbital parameter database.

  13. A rapid and reliable PCR method for genotyping the ABO blood group.

    PubMed

    O'Keefe, D S; Dobrovic, A

    1993-01-01

    The ABO blood group has been used extensively as a marker in population studies, epidemiology, and forensic work. However, until the cloning of the gene, it was not possible to determine the genotype of group A and B individuals without recourse to family studies. We have developed a method to determine the ABO genotype directly from human DNA using multiplex PCR and restriction enzyme analysis. Two PCR fragments spanning positions 258 and 700 of the cDNA sequence are amplified. The site at position 258 allows us to differentiate the O allele from the A and B alleles. The site at position 700 allows us to distinguish the B allele from the A and O alleles. Analysis at the two sites thus allows us to distinguish the three alleles. The multiplex PCR product is digested separately with four enzymes, two for each of the sites. The pair of enzymes for each site cut in a reciprocal fashion. Whereas one enzyme for each site is theoretically sufficient for genotyping, the use of complementary pairs of enzymes prevents the assignment of a false genotype as a result of false negative or partial digestion. This method is fast and reliable, does not rely on probing of blots, and should be widely applicable.

  14. Rapid and reliable determination of illegal adulterant in herbal medicines and dietary supplements by LC/MS/MS.

    PubMed

    Liang, Qionglin; Qu, Jun; Luo, Guoan; Wang, Yiming

    2006-02-13

    In recent years, dietary supplements and herbal medicines are increasing in popularity all over the world. However, it is problematic that some manufacturers illegally included synthetic drugs in their products. Due to the extremely complex matrices of those products, most existing methods for screening illegal adulterations are time-consuming and liable to false positive. In this paper, a robust LC/MS/MS method for the high-throughput, sensitive and reliable determination of illegal adulterations from herbal medicines and dietary supplements was established. Minimal LC separation was employed and MRM was used to simultaneously monitor the three transitions under their respective optimal collision energy for each compound. Positive results were determined only if well-defined peaks appeared at all of the three transitions and the ratios among the peak areas were within given threshold. In this study, the method had been applied for the screening of nine most commonly adulterated therapeutic substances, such as sildenafil (Viagra) and famotidine, and the lower limits of detection of these compounds ranged from 0.05 to 1.5 ng/ml. Little sample preparation was needed for this method and the analysis time was less than 5 min/sample. The reliability has been demonstrated by the test with blank matrix. Over 200 products that were under suspicion by SDA of China had been assayed and till now no false negative or positive result was found. This method is rapid, simple, reliable and capable of screening multiple adulterants in one run.

  15. 10 CFR 433.8 - Life-cycle costing.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Life-cycle costing. 433.8 Section 433.8 Energy DEPARTMENT... HIGH-RISE RESIDENTIAL BUILDINGS § 433.8 Life-cycle costing. Each Federal agency shall determine life... choose to use any of four methods, including lower life-cycle costs, positive net savings, savings-to...

  16. 10 CFR 433.8 - Life-cycle costing.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Life-cycle costing. 433.8 Section 433.8 Energy DEPARTMENT... HIGH-RISE RESIDENTIAL BUILDINGS § 433.8 Life-cycle costing. Each Federal agency shall determine life... choose to use any of four methods, including lower life-cycle costs, positive net savings, savings-to...

  17. 10 CFR 433.8 - Life-cycle costing.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Life-cycle costing. 433.8 Section 433.8 Energy DEPARTMENT... HIGH-RISE RESIDENTIAL BUILDINGS § 433.8 Life-cycle costing. Each Federal agency shall determine life... choose to use any of four methods, including lower life-cycle costs, positive net savings, savings-to...

  18. 13 CFR 120.1721 - SBA's right to investigate.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false SBA's right to investigate. 120... Establishment of SBA Secondary Market Guarantee Program for First Lien Position 504 Loan Pools § 120.1721 SBA's right to investigate. SBA may undertake such investigation as it deems necessary to determine whether it...

  19. 29 CFR 1614.201 - Age Discrimination in Employment Act.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Age Discrimination in Employment Act. 1614.201 Section 1614... SECTOR EQUAL EMPLOYMENT OPPORTUNITY Provisions Applicable to Particular Complaints § 1614.201 Age... establishes a maximum age requirement for the position on the basis of a determination that age is a bona fide...

  20. 29 CFR 1614.201 - Age Discrimination in Employment Act.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 4 2012-07-01 2012-07-01 false Age Discrimination in Employment Act. 1614.201 Section 1614... SECTOR EQUAL EMPLOYMENT OPPORTUNITY Provisions Applicable to Particular Complaints § 1614.201 Age... establishes a maximum age requirement for the position on the basis of a determination that age is a bona fide...

  1. 12 CFR 268.201 - Age Discrimination in Employment Act.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 3 2011-01-01 2011-01-01 false Age Discrimination in Employment Act. 268.201... Age Discrimination in Employment Act. (a) As an alternative to filing a complaint under this part, an... Commission establishes a maximum age requirement for the position on the basis of a determination that age is...

  2. 29 CFR 1614.201 - Age Discrimination in Employment Act.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 4 2014-07-01 2014-07-01 false Age Discrimination in Employment Act. 1614.201 Section 1614... SECTOR EQUAL EMPLOYMENT OPPORTUNITY Provisions Applicable to Particular Complaints § 1614.201 Age... establishes a maximum age requirement for the position on the basis of a determination that age is a bona fide...

  3. 12 CFR 268.201 - Age Discrimination in Employment Act.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Age Discrimination in Employment Act. 268.201... Age Discrimination in Employment Act. (a) As an alternative to filing a complaint under this part, an... Commission establishes a maximum age requirement for the position on the basis of a determination that age is...

  4. 29 CFR 1614.201 - Age Discrimination in Employment Act.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 4 2011-07-01 2011-07-01 false Age Discrimination in Employment Act. 1614.201 Section 1614... SECTOR EQUAL EMPLOYMENT OPPORTUNITY Provisions Applicable to Particular Complaints § 1614.201 Age... establishes a maximum age requirement for the position on the basis of a determination that age is a bona fide...

  5. 29 CFR 1614.201 - Age Discrimination in Employment Act.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 4 2013-07-01 2013-07-01 false Age Discrimination in Employment Act. 1614.201 Section 1614... SECTOR EQUAL EMPLOYMENT OPPORTUNITY Provisions Applicable to Particular Complaints § 1614.201 Age... establishes a maximum age requirement for the position on the basis of a determination that age is a bona fide...

  6. 5 CFR 532.317 - Use of data from the nearest similar area.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Use of data from the nearest similar area. 532.317 Section 532.317 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS PREVAILING RATE SYSTEMS Determining Rates for Principal Types of Positions § 532.317 Use of data...

  7. 41 CFR 102-5.85 - What information should our determination for field work include if positions are identified...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What information should...? 102-5.85 Section 102-5.85 Public Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION GENERAL 5-HOME-TO-WORK TRANSPORTATION Authorizing...

  8. The expediency of peritoneal lavage for blunt trauma in children.

    PubMed

    Drew, R; Perry, J F; Fischer, R P

    1977-12-01

    Two hundred and thirty children, ten years of age or younger, suspected of having blunt abdominal injuries underwent diagnostic peritoneal lavage. Peritoneal lavage was 99.1 per cent accurate in determining the presence or absence of abdominal injuries. One patient had a false-positive peritoneal lavage. Sixty-nine of the 70 patients with blunt abdominal injuries, who underwent peritoneal lavage, had a positive peritoneal lavage; one patient had a false-negative peritoneal levage. Ninety-one per cent of the positive peritoneal lavages were grossly positive for hemoperitoneum. All 11 children with extraperitoneal abdominal injuries had positive peritoneal lavages from associated intraperitoneal injeries. The mortality for children with blunt abdominal injuries was 19.4 per cent. Intra-abdominal injuries were solely responsible for 29 per cent of the deaths and were a major contributing factor in an additional 21 per cent of the deaths. The routine use of diagnostic peritoneal lavage during the initial evaluation of blunt abdominal trauma was, in large part, responsible for the rapid, definitive treatment which -he children with abdominal injuries received. Sixty-five per cent of the children underwent exploratory laparotomy within one hour of admission to the hospital.

  9. Frequency of false positive rapid HIV serologic tests in African men and women receiving PrEP for HIV prevention: implications for programmatic roll-out of biomedical interventions.

    PubMed

    Ndase, Patrick; Celum, Connie; Kidoguchi, Lara; Ronald, Allan; Fife, Kenneth H; Bukusi, Elizabeth; Donnell, Deborah; Baeten, Jared M

    2015-01-01

    Rapid HIV assays are the mainstay of HIV testing globally. Delivery of effective biomedical HIV prevention strategies such as antiretroviral pre-exposure prophylaxis (PrEP) requires periodic HIV testing. Because rapid tests have high (>95%) but imperfect specificity, they are expected to generate some false positive results. We assessed the frequency of true and false positive rapid results in the Partners PrEP Study, a randomized, placebo-controlled trial of PrEP. HIV testing was performed monthly using 2 rapid tests done in parallel with HIV enzyme immunoassay (EIA) confirmation following all positive rapid tests. A total of 99,009 monthly HIV tests were performed; 98,743 (99.7%) were dual-rapid HIV negative. Of the 266 visits with ≥1 positive rapid result, 99 (37.2%) had confirmatory positive EIA results (true positives), 155 (58.3%) had negative EIA results (false positives), and 12 (4.5%) had discordant EIA results. In the active PrEP arms, over two-thirds of visits with positive rapid test results were false positive results (69.2%, 110 of 159), although false positive results occurred at <1% (110/65,945) of total visits. When HIV prevalence or incidence is low due to effective HIV prevention interventions, rapid HIV tests result in a high number of false relative to true positive results, although the absolute number of false results will be low. Program roll-out for effective interventions should plan for quality assurance of HIV testing, mechanisms for confirmatory HIV testing, and counseling strategies for persons with positive rapid test results.

  10. Experimental investigation of observation error in anuran call surveys

    USGS Publications Warehouse

    McClintock, B.T.; Bailey, L.L.; Pollock, K.H.; Simons, T.R.

    2010-01-01

    Occupancy models that account for imperfect detection are often used to monitor anuran and songbird species occurrence. However, presenceabsence data arising from auditory detections may be more prone to observation error (e.g., false-positive detections) than are sampling approaches utilizing physical captures or sightings of individuals. We conducted realistic, replicated field experiments using a remote broadcasting system to simulate simple anuran call surveys and to investigate potential factors affecting observation error in these studies. Distance, time, ambient noise, and observer abilities were the most important factors explaining false-negative detections. Distance and observer ability were the best overall predictors of false-positive errors, but ambient noise and competing species also affected error rates for some species. False-positive errors made up 5 of all positive detections, with individual observers exhibiting false-positive rates between 0.5 and 14. Previous research suggests false-positive errors of these magnitudes would induce substantial positive biases in standard estimators of species occurrence, and we recommend practices to mitigate for false positives when developing occupancy monitoring protocols that rely on auditory detections. These recommendations include additional observer training, limiting the number of target species, and establishing distance and ambient noise thresholds during surveys. ?? 2010 The Wildlife Society.

  11. Lymphangiography

    PubMed Central

    Kadin, Michael R.; Thompson, Ronald W.

    1974-01-01

    Since the introduction of “staging laparotomy” (to determine the disease's stage) in assessing Hodgkin's disease, some observers have argued that lymphangiography could be safely omitted in the initial diagnostic evaluation. To test these opinions a series of 75 patients with Hodgkin's disease who had a staging laparotomy and histological correlation with lymphangiograms was reviewed. Of 16 examinations with positive results, one proved to be a false positive. Of the 14 examinations with equivocal results, one proved histologically positive. In the remaining 45 lymphangiograms, five were falsely negative. In all five of these patients abdominal lymph nodes were involved, but in areas that do not routinely opacify on lower extremity lymphangiography. The overall accuracy was 90 percent. Therapeutically, the lymphangiogram permits accurate planning for treatment by radiation therapy so that all known disease is treated and yet bone marrow is not excessively irradiated. Changes in lymph node architecture after therapy provide valuable information as to regression of the disease or signs of its early recurrence. ImagesFigure 1.Figure 2.Figure 3.Figure 4.Figure 5.Figure 6.Figure 7. PMID:4816398

  12. Memory for media: investigation of false memories for negatively and positively charged public events.

    PubMed

    Porter, Stephen; Taylor, Kristian; Ten Brinke, Leanne

    2008-01-01

    Despite a large body of false memory research, little has addressed the potential influence of an event's emotional content on susceptibility to false recollections. The Paradoxical Negative Emotion (PNE) hypothesis predicts that negative emotion generally facilitates memory but also heightens susceptibility to false memories. Participants were asked whether they could recall 20 "widely publicised" public events (half fictitious) ranging in emotional valence, with or without visual cues. Participants recalled a greater number of true negative events (M=3.31/5) than true positive (M=2.61/5) events. Nearly everyone (95%) came to recall at least one false event (M=2.15 false events recalled). Further, more than twice as many participants recalled any false negative (90%) compared to false positive (41.7%) events. Negative events, in general, were associated with more detailed memories and false negative event memories were more detailed than false positive event memories. Higher dissociation scores were associated with false recollections of negative events, specifically.

  13. Are overreferrals on developmental screening tests really a problem?

    PubMed

    Glascoe, F P

    2001-01-01

    Developmental screening tests, even those meeting standards for screening test accuracy, produce numerous false-positive results for 15% to 30% of children. This is thought to produce unnecessary referrals for diagnostic testing or special services and increase the cost of screening programs. To explore whether children who pass screening tests differ in important ways from those who do not and to determine whether children overreferred for testing benefit from the scrutiny of diagnostic testing and treatment planning. Subjects were a national sample of 512 parents and their children (age range of the children, 7 months to 8 years) who participated in validation studies of various screening tests. Psychological examiners adhering to standardized directions obtained informed consent and administered at least 2 developmental screening measures (the Brigance Screens, the Battelle Developmental Inventory Screening Test, the Denver-II, and the Parents' Evaluations of Developmental Status) and a concurrent battery of diagnostic measures, including tests of intelligence, language, and academic achievement (for children aged 2(1/2) years and older). The performance on diagnostic measures of children who failed screening but were not found to have a disability (false positives) was compared with that of children who passed screening and did not have a disability on diagnostic testing (true negatives). Children with false-positive scores performed significantly (P<.001) lower on diagnostic measures than did children with true-negative scores. The false-positive group had scores in adaptive behavior, language, intelligence, and academic achievement that were 9 to 14 points lower than the scores of those in the true-negative group. When viewing the likelihood of scoring below the 25th percentile on diagnostic measures, children with false-positive scores had a relative risk of 2.6 in adaptive behavior (95% confidence interval [CI], 1.67-4.21), 3.1 in language skills (95% CI, 1.90-5.20), 6.7 on intelligence tests (95% CI, 3.28-13.50), and 4.9 on academic measures (95% CI, 2.61-9.28). Overall, 151 (70%) of the children with false-positive results scored below the 25th percentile on 1 or more diagnostic measures (the point at which most children have difficulty benefiting from typical classroom instruction) in contrast with 64 (29%) of the children with true-negative scores (odds ratio, 5.6; 95% CI, 3.73-8.49). Children with false-positive scores were also more likely to be nonwhite and to have parents who had not graduated from high school. Performance differences between children with true-negative scores and children with false-positive scores continued to be significant (P<.001) even after adjusting for sociodemographic differences between groups. Children overreferred for diagnostic testing by developmental screens perform substantially lower than children with true-negative scores on measures of intelligence, language, and academic achievement-the 3 best predictors of school success. These children also carry more psychosocial risk factors, such as limited parental education and minority status. Thus, children with false-positive screening results are an at-risk group for whom diagnostic testing may not be an unnecessary expense but rather a beneficial and needed service that can help focus intervention efforts. Although such testing will not indicate a need for special education placement, it can be useful in identifying children's needs for other programs known to improve language, cognitive, and academic skills, such as Head Start, Title I services, tutoring, private speech-language therapy, and quality day care.

  14. The effect of carbonated beverages on colorimetric end-tidal CO(2) determination

    PubMed

    Qureshi; Park; Sturmann; Hsu

    2000-10-01

    Esophageal intubation is a significant complication of attempted airway control. Colorimetric end-tidal CO(2) monitors are highly sensitive and specific for detecting the presence of CO(2). There are reports of false-positive end-tidal CO(2) readings from esophageal intubations in patients who had ingested carbonated beverages. OBJECTIVE: To determine whether carbonated gastric contents can affect colorimetric end-tidal CO(2) readings. METHODS: End-tidal CO(2) was measured in sacrificed piglets at measured time intervals after instillation of 5-, 10-, 15-, and 20-mL aliquots of Diet Coke were placed into the stomach via a 28-French orogastric tube followed by esophageal intubation. The stomach was completely evacuated prior to each instillation and rechecked for baseline CO(2). RESULTS: Compiled data from three piglets (20-30 kg). Piglets were not ventilated or moved and determinations were measured at 20 degrees while supine. All data collected within 2 hours postmortem (table 24-1). CONCLUSIONS: The colorimetric end-tidal CO(2) turned "yellow" and did not change to blue with extended insufflations. The CO(2) of a small quantity of carbonated beverage in the stomach could be "blown off" by multiple insufflations. We conclude that esophageal intubation in the setting of recent ingestion of a carbonated beverage may result in a false-positive end-tidal CO(2) determination.

  15. Generalized site occupancy models allowing for false positive and false negative errors

    USGS Publications Warehouse

    Royle, J. Andrew; Link, W.A.

    2006-01-01

    Site occupancy models have been developed that allow for imperfect species detection or ?false negative? observations. Such models have become widely adopted in surveys of many taxa. The most fundamental assumption underlying these models is that ?false positive? errors are not possible. That is, one cannot detect a species where it does not occur. However, such errors are possible in many sampling situations for a number of reasons, and even low false positive error rates can induce extreme bias in estimates of site occupancy when they are not accounted for. In this paper, we develop a model for site occupancy that allows for both false negative and false positive error rates. This model can be represented as a two-component finite mixture model and can be easily fitted using freely available software. We provide an analysis of avian survey data using the proposed model and present results of a brief simulation study evaluating the performance of the maximum-likelihood estimator and the naive estimator in the presence of false positive errors.

  16. Assessment of real-time PCR cycle threshold values in Microsporum canis culture-positive and culture-negative cats in an animal shelter: a field study.

    PubMed

    Jacobson, Linda S; McIntyre, Lauren; Mykusz, Jenny

    2018-02-01

    Objectives Real-time PCR provides quantitative information, recorded as the cycle threshold (Ct) value, about the number of organisms detected in a diagnostic sample. The Ct value correlates with the number of copies of the target organism in an inversely proportional and exponential relationship. The aim of the study was to determine whether Ct values could be used to distinguish between culture-positive and culture-negative samples. Methods This was a retrospective analysis of Ct values from dermatophyte PCR results in cats with suspicious skin lesions or suspected exposure to dermatophytosis. Results One hundred and thirty-two samples were included. Using culture as the gold standard, 28 were true positives, 12 were false positives and 92 were true negatives. The area under the curve for the pretreatment time point was 96.8% (95% confidence interval [CI] 94.2-99.5) compared with 74.3% (95% CI 52.6-96.0) for pooled data during treatment. Before treatment, a Ct cut-off of <35.7 (approximate DNA count 300) provided a sensitivity of 92.3% and specificity of 95.2%. There was no reliable cut-off Ct value between culture-positive and culture-negative samples during treatment. Ct values prior to treatment differed significantly between the true-positive and false-positive groups ( P = 0.0056). There was a significant difference between the pretreatment and first and second negative culture time points ( P = 0.0002 and P <0.0001, respectively). However, there was substantial overlap between Ct values for true positives and true negatives, and for pre- and intra-treatment time points. Conclusions and relevance Ct values had limited usefulness for distinguishing between culture-positive and culture-negative cases when field study samples were analyzed. In addition, Ct values were less reliable than fungal culture for determining mycological cure.

  17. Comparison of 4th-Generation HIV Antigen/Antibody Combination Assay With 3rd-Generation HIV Antibody Assays for the Occurrence of False-Positive and False-Negative Results.

    PubMed

    Muthukumar, Alagarraju; Alatoom, Adnan; Burns, Susan; Ashmore, Jerry; Kim, Anne; Emerson, Brian; Bannister, Edward; Ansari, M Qasim

    2015-01-01

    To assess the false-positive and false-negative rates of a 4th-generation human immunodeficiency virus (HIV) assay, the Abbott ARCHITECT, vs 2 HIV 3rd-generation assays, the Siemens Centaur and the Ortho-Clinical Diagnostics Vitros. We examined 123 patient specimens. In the first phase of the study, we compared 99 specimens that had a positive screening result via the 3rd-generation Vitros assay (10 positive, 82 negative, and 7 indeterminate via confirmatory immunofluorescent assay [IFA]/Western blot [WB] testing). In the second phase, we assessed 24 HIV-1 RNA-positive (positive result via the nuclear acid amplification test [NAAT] and negative/indeterminate results via the WB test) specimens harboring acute HIV infection. The 4th-generation ARCHITECT assay yielded fewer false-positive results (n = 2) than the 3rd-generation Centaur (n = 9; P = .02) and Vitros (n = 82; P <.001) assays. One confirmed positive case had a false-negative result via the Centaur assay. When specimens from the 24 patients with acute HIV-1 infection were tested, the ARCHITECT assay yielded fewer false-negative results (n = 5) than the Centaur (n = 10) (P = .13) and the other 3rd-generation tests (n = 16) (P = .002). This study indicates that the 4th-generation ARCHITECT HIV assay yields fewer false-positive and false-negative results than the 3rd-generation HIV assays we tested. Copyright© by the American Society for Clinical Pathology (ASCP).

  18. A critical reappraisal of false negative sentinel lymph node biopsy in melanoma.

    PubMed

    Manca, G; Romanini, A; Rubello, D; Mazzarri, S; Boni, G; Chiacchio, S; Tredici, M; Duce, V; Tardelli, E; Volterrani, D; Mariani, G

    2014-06-01

    Lymphatic mapping and sentinel lymph node biopsy (SLNB) have completely changed the clinical management of cutaneous melanoma. This procedure has been accepted worldwide as a recognized method for nodal staging. SLNB is able to accurately determine nodal basin status, providing the most useful prognostic information. However, SLNB is not a perfect diagnostic test. Several large-scale studies have reported a relatively high false-negative rate (5.6-21%), correctly defined as the proportion of false-negative results with respect to the total number of "actual" positive lymph nodes. The main purpose of this review is to address the technical issues that nuclear physicians, surgeons, and pathologists should carefully consider to improve the accuracy of SLNB by minimizing its false-negative rate. In particular, SPECT/CT imaging has demonstrated to be able to identify a greater number of sentinel lymph nodes (SLNs) than those found by planar lymphoscintigraphy. Furthermore, a unique definition in the international guidelines is missing for the operational identification of SLNs, which may be partly responsible for this relatively high false-negative rate of SLNB. Therefore, it is recommended for the scientific community to agree on the radioactive counting rate threshold so that the surgeon can be better radioguided to detect all the lymph nodes which are most likely to harbor metastases. Another possible source of error may be linked to the examination of the harvested SLNs by conventional histopathological methods. A more careful and extensive SLN analysis (e.g. molecular analysis by RT-PCR) is able to find more positive nodes, so that the false-negative rate is reduced. Older age at diagnosis, deeper lesions, histologic ulceration, head-neck anatomical location of primary lesions are the clinical factors associated with false-negative SLNBs in melanoma patients. There is still much controversy about the clinical significance of a false-negative SLNB on the prognosis of melanoma patients. Indeed, most studies have failed to show that there is worse melanoma-specific survival for false-negative compared to true-positive SLNB patients.

  19. False-positive alarms for bacterial screening of platelet concentrates with BacT/ALERT new-generation plastic bottles: a multicenter pilot study.

    PubMed

    Hundhausen, T; Müller, T H

    2005-08-01

    The microbial detection system BacT/ALERT (bioMérieux) is widely used to monitor bacterial contamination of platelet concentrates (PCs). Recently, the manufacturer introduced polycarbonate culture bottles and a modified pH-sensitive liquid emulsion sensor as microbial growth indicator. This reconfigured assay was investigated in a routine setting. In each of eight transfusion centers, samples from 500 consecutive PCs were monitored for 1 week. For all PCs with a positive BacT/ALERT signal, retained samples and, if available, original PC containers and concomitant red blood cell concentrates were analyzed independently. Initially BacT/ALERT-positive PCs without bacterial identification in any sample were defined as false-positive. BacT/ALERT-positive PCs with bacteria in the first sample only were called potentially positive. PCs with bacteria in the first sample and the same strain in at least one additional sample were accepted as positive. Five PCs (0.13%) were positive, 9 PCs (0.23%) were potentially positive, and 35 PCs (0.9%) were false-positive. The rate of false-positive BacT/ALERT results varied substantially between centers (<0.2%-3.2%). Tracings from false-positive cultures lacked an exponential increase of the signal during incubation. Most of these false-positives were due to malfunctioning cells in various BacT/ALERT incubation units. Careful assessment of individual tracings of samples with positive signals helps to identify malfunctioning incubation units. Their early shutdown or replacement minimizes the high rate of unrectifiable product rejects attributed to false-positive alarms and avoids unnecessary concern of doctors and patients after conversion to a reconfigured BacT/ALERT assay.

  20. Accuracy in inference of nursing diagnoses in heart failure patients.

    PubMed

    Pereira, Juliana de Melo Vellozo; Cavalcanti, Ana Carla Dantas; Lopes, Marcos Venícios de Oliveira; da Silva, Valéria Gonçalves; de Souza, Rosana Oliveira; Gonçalves, Ludmila Cuzatis

    2015-01-01

    Heart failure (HF) is a common cause of hospitalization and requires accuracy in clinical judgment and appropriate nursing diagnoses. to determine the accuracy of nursing diagnoses of fatigue, intolerance to activity and decreased cardiac output in hospitalized HF patients. descriptive study applied to nurses with experience in NANDA-I and/or HF nursing diagnoses. Evaluation and accuracy were determined by calculating efficacy (E), false negative (FN), false positive (FP) and trend (T) measures. Nurses who showed acceptable inspection for two diagnoses were selected. the nursing diagnosis of fatigue was the most commonly mistaken diagnosis identified by the nursing evaluators. the search for improving diagnostic accuracy reaffirms the need for continuous and specific training to improve the diagnosis capability of nurses. the training allowed the exercise of clinical judgment and better accuracy of nurses.

  1. Multi-centre evaluation of the Determine HIV Combo assay when used for point of care testing in a high risk clinic-based population.

    PubMed

    Conway, Damian P; Holt, Martin; McNulty, Anna; Couldwell, Deborah L; Smith, Don E; Davies, Stephen C; Cunningham, Philip; Keen, Phillip; Guy, Rebecca

    2014-01-01

    Determine HIV Combo (DHC) is the first point of care assay designed to increase sensitivity in early infection by detecting both HIV antibody and antigen. We conducted a large multi-centre evaluation of DHC performance in Sydney sexual health clinics. We compared DHC performance (overall, by test component and in early infection) with conventional laboratory HIV serology (fourth generation screening immunoassay, supplementary HIV antibody, p24 antigen and Western blot tests) when testing gay and bisexual men attending four clinic sites. Early infection was defined as either acute or recent HIV infection acquired within the last six months. Of 3,190 evaluation specimens, 39 were confirmed as HIV-positive (12 with early infection) and 3,133 were HIV-negative by reference testing. DHC sensitivity was 87.2% overall and 94.4% and 0% for the antibody and antigen components, respectively. Sensitivity in early infection was 66.7% (all DHC antibody reactive) and the DHC antigen component detected none of nine HIV p24 antigen positive specimens. Median HIV RNA was higher in false negative than true positive cases (238,025 vs. 37,591 copies/ml; p = 0.022). Specificity overall was 99.4% with the antigen component contributing to 33% of false positives. The DHC antibody component detected two thirds of those with early infection, while the DHC antigen component did not enhance performance during point of care HIV testing in a high risk clinic-based population.

  2. Is there a positive bias in false recognition? Evidence from confabulating amnesia patients.

    PubMed

    Alkathiri, Nura H; Morris, Robin G; Kopelman, Michael D

    2015-10-01

    Although there is some evidence for a positive emotional bias in the content of confabulations in brain damaged patients, findings have been inconsistent. The present study used the semantic-associates procedure to induce false recall and false recognition in order to examine whether a positive bias would be found in confabulating amnesic patients, relative to non-confabulating amnesic patients and healthy controls. Lists of positive, negative and neutral words were presented in order to induce false recall or false recognition of non-presented (but semantically associated) words. The latter were termed 'critical intrusions'. Thirteen confabulating amnesic patients, 13 non-confabulating amnesic patients and 13 healthy controls were investigated. Confabulating patients falsely recognised a higher proportion of positive (but unrelated) words, compared with non-confabulating patients and healthy controls. No differences were found for recall memory. Signal detection analysis, however, indicated that the positive bias for false recognition memory might reflect weaker memory in the confabulating amnesic group. This suggested that amnesia patients with weaker memory are more likely to confabulate and the content of these confabulations are more likely to be positive. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Study of false positives in 5-ALA induced photodynamic diagnosis of bladder carcinoma

    NASA Astrophysics Data System (ADS)

    Draga, Ronald O. P.; Grimbergen, Matthijs C. M.; Kok, Esther T.; Jonges, Trudy G. N.; Bosch, J. L. H. R.

    2009-02-01

    Photodynamic diagnosis (PDD) is a technique that enhances the detection of tumors during cystoscopy using a photosensitizer which accumulates primarily in cancerous cells and will fluoresce when illuminated by violetblue light. A disadvantage of PDD is the relatively low specificity. In this retrospective study we aimed to identify predictors for false positive findings in PDD. Factors such as gender, age, recent transurethral resection of bladder tumors (TURBT), previous intravesical therapy (IVT) and urinary tract infections (UTIs) were examined for association with the false positive rates in a multivariate analysis. Data of 366 procedures and 200 patients were collected. Patients were instilled with 5-aminolevulinic acid (5-ALA) intravesically and 1253 biopsies were taken from tumors and suspicious lesions. Female gender and TURBT are independent predictors of false positives in PDD. However, previous intravesical therapy with Bacille Calmette-Guérin is also an important predictor of false positives. The false positive rate decreases during the first 9-12 weeks after the latest TURBT and the latest intravesical chemotherapy. Although shortly after IVT and TURBT false positives increase, PDD improves the diagnostic sensitivity and results in more adequate treatment strategies in a significant number of patients.

  4. Comparison of body mass index, waist circumference, and waist to height ratio in the prediction of hypertension and diabetes mellitus: Filipino-American women cardiovascular study.

    PubMed

    Battie, Cynthia A; Borja-Hart, Nancy; Ancheta, Irma B; Flores, Rene; Rao, Goutham; Palaniappan, Latha

    2016-12-01

    The relative ability of three obesity indices to predict hypertension (HTN) and diabetes (DM) and the validity of using Asian-specific thresholds of these indices were examined in Filipino-American women (FAW). Filipino-American women ( n  = 382), 40-65 years of age were screened for hypertension (HTN) and diabetes (DM) in four major US cities. Body mass index (BMI), waist circumference (WC) and waist circumference to height ratio (WHtR) were measured. ROC analyses determined that the three obesity measurements were similar in predicting HTN and DM (AUC: 0.6-0.7). The universal WC threshold of ≥ 35 in. missed 13% of the hypertensive patients and 12% of the diabetic patients. The Asian WC threshold of ≥ 31.5 in. increased detection of HTN and DM but with a high rate of false positives. The traditional BMI ≥ 25 kg/m 2 threshold missed 35% of those with hypertension and 24% of those with diabetes. The Asian BMI threshold improved detection but resulted in a high rate of false positives. The suggested WHtR cut-off of ≥ 0.5 missed only 1% of those with HTN and 0% of those with DM. The three obesity measurements had similar but modest ability to predict HTN and DM in FAW. Using Asian-specific thresholds increased accuracy but with a high rate of false positives. Whether FAW, especially at older ages, should be encouraged to reach these lower thresholds needs further investigation because of the high false positive rates.

  5. 5 CFR 532.317 - Use of data from the nearest similar area.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... REGULATIONS PREVAILING RATE SYSTEMS Determining Rates for Principal Types of Positions § 532.317 Use of data... 5 Administrative Personnel 1 2013-01-01 2013-01-01 false Use of data from the nearest similar area... subpart, analyze and use the acceptable data from the nearest similar wage area together with the data...

  6. 5 CFR 532.317 - Use of data from the nearest similar area.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... REGULATIONS PREVAILING RATE SYSTEMS Determining Rates for Principal Types of Positions § 532.317 Use of data... 5 Administrative Personnel 1 2012-01-01 2012-01-01 false Use of data from the nearest similar area... subpart, analyze and use the acceptable data from the nearest similar wage area together with the data...

  7. Erasure Analyses: Reducing the Number of False Positives

    ERIC Educational Resources Information Center

    McClintock, Joseph Clair

    2015-01-01

    Erasure analysis is the study of the pattern or quantity of erasures on multiple-choice paper-and-pencil examinations, to determine whether erasures were made post-testing for the purpose of unfairly increasing students' scores. This study examined the erasure data from over 1.4 million exams, taken by more than 600,000 students. Three…

  8. Accounting for false-positive acoustic detections of bats using occupancy models

    USGS Publications Warehouse

    Clement, Matthew J.; Rodhouse, Thomas J.; Ormsbee, Patricia C.; Szewczak, Joseph M.; Nichols, James D.

    2014-01-01

    4. Synthesis and applications. Our results suggest that false positives sufficient to affect inferences may be common in acoustic surveys for bats. We demonstrate an approach that can estimate occupancy, regardless of the false-positive rate, when acoustic surveys are paired with capture surveys. Applications of this approach include monitoring the spread of White-Nose Syndrome, estimating the impact of climate change and informing conservation listing decisions. We calculate a site-specific probability of occupancy, conditional on survey results, which could inform local permitting decisions, such as for wind energy projects. More generally, the magnitude of false positives suggests that false-positive occupancy models can improve accuracy in research and monitoring of bats and provide wildlife managers with more reliable information.

  9. The value of confirmatory testing in early infant HIV diagnosis programmes in South Africa: A cost-effectiveness analysis.

    PubMed

    Dunning, Lorna; Francke, Jordan A; Mallampati, Divya; MacLean, Rachel L; Penazzato, Martina; Hou, Taige; Myer, Landon; Abrams, Elaine J; Walensky, Rochelle P; Leroy, Valériane; Freedberg, Kenneth A; Ciaranello, Andrea

    2017-11-01

    The specificity of nucleic acid amplification tests (NAATs) used for early infant diagnosis (EID) of HIV infection is <100%, leading some HIV-uninfected infants to be incorrectly identified as HIV-infected. The World Health Organization recommends that infants undergo a second NAAT to confirm any positive test result, but implementation is limited. Our objective was to determine the impact and cost-effectiveness of confirmatory HIV testing for EID programmes in South Africa. Using the Cost-effectiveness of Preventing AIDS Complications (CEPAC)-Pediatric model, we simulated EID testing at age 6 weeks for HIV-exposed infants without and with confirmatory testing. We assumed a NAAT cost of US$25, NAAT specificity of 99.6%, NAAT sensitivity of 100% for infants infected in pregnancy or at least 4 weeks prior to testing, and a mother-to-child transmission (MTCT) rate at 12 months of 4.9%; we simulated guideline-concordant rates of testing uptake, result return, and antiretroviral therapy (ART) initiation (100%). After diagnosis, infants were linked to and retained in care for 10 years (false-positive) or lifelong (true-positive). All parameters were varied widely in sensitivity analyses. Outcomes included number of infants with false-positive diagnoses linked to ART per 1,000 ART initiations, life expectancy (LE, in years) and per-person lifetime HIV-related healthcare costs. Both without and with confirmatory testing, LE was 26.2 years for HIV-infected infants and 61.4 years for all HIV-exposed infants; clinical outcomes for truly infected infants did not differ by strategy. Without confirmatory testing, 128/1,000 ART initiations were false-positive diagnoses; with confirmatory testing, 1/1,000 ART initiations were false-positive diagnoses. Because confirmatory testing averted costly HIV care and ART in truly HIV-uninfected infants, it was cost-saving: total cost US$1,790/infant tested, compared to US$1,830/infant tested without confirmatory testing. Confirmatory testing remained cost-saving unless NAAT cost exceeded US$400 or the HIV-uninfected status of infants incorrectly identified as infected was ascertained and ART stopped within 3 months of starting. Limitations include uncertainty in the data used in the model, which we examined with sensitivity and uncertainty analyses. We also excluded clinical harms to HIV-uninfected infants incorrectly treated with ART after false-positive diagnosis (e.g., medication toxicities); including these outcomes would further increase the value of confirmatory testing. Without confirmatory testing, in settings with MTCT rates similar to that of South Africa, more than 10% of infants who initiate ART may reflect false-positive diagnoses. Confirmatory testing prevents inappropriate HIV diagnosis, is cost-saving, and should be adopted in all EID programmes.

  10. Evaluation of an enzyme immunoassay system for measuring herpes simplex virus (HSV) type 1-specific and HSV type 2-specific IgG antibodies.

    PubMed

    Prince, H E; Ernst, C E; Hogrefe, W R

    2000-01-01

    MRL Diagnostics has developed a dual enzyme immunoassay (EIA) system that employs the recombinant Herpes Simplex Virus (HSV) type-specific glycoproteins G1 (HSV1) and G2 (HSV2) to detect HSV type-specific IgG antibodies. This system was evaluated using 155 consecutive sera previously tested in a conventional dual EIA system (Zeus) that employs multiple HSV1 and HSV2 proteins to detect type-common as well as type-specific antibodies. Sera were also analyzed by Western blot to determine the true HSV type-specific IgG reactivity pattern. Of 110 sera giving concordant reactivity patterns in the MRL and Zeus EIA systems, 108 (98%) also displayed concordant Western blot patterns; two sera gave false positive HSV2 reactivity in both EIA systems. Of 45 sera giving discordant MRL and Zeus EIA reactivity patterns, 41 (91%) displayed a Western blot reactivity pattern that matched the MRL reactivity pattern. Both the HSV1 IgG component and the HSV2 IgG component of the MRL EIA system were 100% sensitive and > 95% specific. In contrast, the Zeus HSV1 IgG EIA was 98% sensitive and 79% specific, and the Zeus HSV2 IgG EIA was 85% sensitive and 79% specific. An analysis of the distribution of index values in the MRL EIA system showed that low-positive values (1.0-3.0) were rare, but, when detected, often represented false positive results; only 11 MRL low-positive results were observed, but all 6 MRL false positive results were found within this low-positive subgroup. These findings show that the MRL dual EIA system effectively detects HSV type-specific IgG antibodies. Copyright 2000 Wiley-Liss, Inc.

  11. Sensitivity and specificity of intrathecal fluorescein and white light excitation for detecting intraoperative cerebrospinal fluid leak in endoscopic skull base surgery: a prospective study.

    PubMed

    Raza, Shaan M; Banu, Matei A; Donaldson, Angela; Patel, Kunal S; Anand, Vijay K; Schwartz, Theodore H

    2016-03-01

    The intraoperative detection of CSF leaks during endonasal endoscopic skull base surgery is critical to preventing postoperative CSF leaks. Intrathecal fluorescein (ITF) has been used at varying doses to aid in the detection of intraoperative CSF leaks. However, the sensitivity and specificity of ITF at certain dosages is unknown. A prospective database of all endoscopic endonasal procedures was reviewed. All patients received 25 mg ITF diluted in 10 ml CSF and were pretreated with dexamethasone and Benadryl. Immediately after surgery, the operating surgeon prospectively noted if there was an intraoperative CSF leak and fluorescein was identified. The sensitivity, specificity, and positive and negative predictive power of ITF for detecting intraoperative CSF leak were calculated. Factors correlating with postoperative CSF leak were determined. Of 419 patients, 35.8% of patients did not show a CSF leak. Fluorescein-tinted CSF (true positive) was noted in 59.7% of patients and 0 false positives were encountered. CSF without fluorescein staining (false negative) was noted in 4.5% of patients. The sensitivity and specificity of ITF were 92.9% and 100%, respectively. The negative and positive predictive values were 88.8% and 100%, respectively. Postoperative CSF leaks only occurred in true positives at a rate of 2.8%. ITF is extremely specific and very sensitive for detecting intraoperative CSF leaks. Although false negatives can occur, these patients do not appear to be at risk for postoperative CSF leak. The use of ITF may help surgeons prevent postoperative CSF leaks by intraoperatively detecting and confirming a watertight repair.

  12. Detection and Species Determination of Malaria Parasites by PCR: Comparison with Microscopy and with ParaSight-F and ICT Malaria Pf Tests in a Clinical Environment

    PubMed Central

    Tham, Jill M.; Lee, Szu Hee; Tan, Theresa M. C.; Ting, Robert C. Y.; Kara, Ursula A. K.

    1999-01-01

    A rapid procedure for the diagnosis of malaria infections directly from dried blood spots by PCR amplification was evaluated with samples from 52 patients. Plasmodium infections were identified with a genus-specific primer set, and species differentiation between Plasmodium falciparum and Plasmodium vivax was analyzed by multiplex PCR. The PCR test with any of the three primer sets was able to detect as few as four parasites per microliter by gel electrophoresis or by nonisotopic paper hybridization chromatography. The diagnoses obtained by PCR correlated closely with those obtained by Giemsa staining except for two samples observed to have mixed P. falciparum-P. vivax infections. These were initially missed by microscopic analysis. In comparison with antigen-capture assays for P. falciparum, the PCR assays were able to detect three infections that were missed by the ParaSight-F test. The PCR test was negative for nine ParaSight-F-positive samples and one ICT Malaria Pf-positive sample, and these were confirmed to be false-positive results. The PCR thus gave no false-negative or false-positive results. Patients undergoing antimalarial therapy were also monitored by the PCR assay. Four of seven patients who were PCR positive for P. vivax at the time of discharge were later readmitted to the hospital with a recurrence of P. vivax infection. We would like to propose that PCR is a sensitive and easy method that can serve as a useful addition to microscopy for the diagnosis and the clinical monitoring of treatment of malaria. PMID:10203469

  13. Avoiding false positive antigen detection by flow cytometry on blood cell derived microparticles: the importance of an appropriate negative control.

    PubMed

    Crompot, Emerence; Van Damme, Michael; Duvillier, Hugues; Pieters, Karlien; Vermeesch, Marjorie; Perez-Morga, David; Meuleman, Nathalie; Mineur, Philippe; Bron, Dominique; Lagneaux, Laurence; Stamatopoulos, Basile

    2015-01-01

    Microparticles (MPs), also called microvesicles (MVs) are plasma membrane-derived fragments with sizes ranging from 0.1 to 1μm. Characterization of these MPs is often performed by flow cytometry but there is no consensus on the appropriate negative control to use that can lead to false positive results. We analyzed MPs from platelets, B-cells, T-cells, NK-cells, monocytes, and chronic lymphocytic leukemia (CLL) B-cells. Cells were purified by positive magnetic-separation and cultured for 48h. Cells and MPs were characterized using the following monoclonal antibodies (CD19,20 for B-cells, CD3,8,5,27 for T-cells, CD16,56 for NK-cells, CD14,11c for monocytes, CD41,61 for platelets). Isolated MPs were stained with annexin-V-FITC and gated between 300nm and 900nm. The latex bead technique was then performed for easy detection of MPs. Samples were analyzed by Transmission (TEM) and Scanning Electron microscopy (SEM). Annexin-V positive events within a gate of 300-900nm were detected and defined as MPs. Our results confirmed that the characteristic antigens CD41/CD61 were found on platelet-derived-MPs validating our technique. However, for MPs derived from other cell types, we were unable to detect any antigen, although they were clearly expressed on the MP-producing cells in the contrary of several data published in the literature. Using the latex bead technique, we confirmed detection of CD41,61. However, the apparent expression of other antigens (already deemed positive in several studies) was determined to be false positive, indicated by negative controls (same labeling was used on MPs from different origins). We observed that mother cell antigens were not always detected on corresponding MPs by direct flow cytometry or latex bead cytometry. Our data highlighted that false positive results could be generated due to antibody aspecificity and that phenotypic characterization of MPs is a difficult field requiring the use of several negative controls.

  14. Avoiding False Positive Antigen Detection by Flow Cytometry on Blood Cell Derived Microparticles: The Importance of an Appropriate Negative Control

    PubMed Central

    Crompot, Emerence; Van Damme, Michael; Duvillier, Hugues; Pieters, Karlien; Vermeesch, Marjorie; Perez-Morga, David; Meuleman, Nathalie; Mineur, Philippe; Bron, Dominique; Lagneaux, Laurence; Stamatopoulos, Basile

    2015-01-01

    Background Microparticles (MPs), also called microvesicles (MVs) are plasma membrane-derived fragments with sizes ranging from 0.1 to 1μm. Characterization of these MPs is often performed by flow cytometry but there is no consensus on the appropriate negative control to use that can lead to false positive results. Materials and Methods We analyzed MPs from platelets, B-cells, T-cells, NK-cells, monocytes, and chronic lymphocytic leukemia (CLL) B-cells. Cells were purified by positive magnetic-separation and cultured for 48h. Cells and MPs were characterized using the following monoclonal antibodies (CD19,20 for B-cells, CD3,8,5,27 for T-cells, CD16,56 for NK-cells, CD14,11c for monocytes, CD41,61 for platelets). Isolated MPs were stained with annexin-V-FITC and gated between 300nm and 900nm. The latex bead technique was then performed for easy detection of MPs. Samples were analyzed by Transmission (TEM) and Scanning Electron microscopy (SEM). Results Annexin-V positive events within a gate of 300-900nm were detected and defined as MPs. Our results confirmed that the characteristic antigens CD41/CD61 were found on platelet-derived-MPs validating our technique. However, for MPs derived from other cell types, we were unable to detect any antigen, although they were clearly expressed on the MP-producing cells in the contrary of several data published in the literature. Using the latex bead technique, we confirmed detection of CD41,61. However, the apparent expression of other antigens (already deemed positive in several studies) was determined to be false positive, indicated by negative controls (same labeling was used on MPs from different origins). Conclusion We observed that mother cell antigens were not always detected on corresponding MPs by direct flow cytometry or latex bead cytometry. Our data highlighted that false positive results could be generated due to antibody aspecificity and that phenotypic characterization of MPs is a difficult field requiring the use of several negative controls. PMID:25978814

  15. Uncertainty in biological monitoring: a framework for data collection and analysis to account for multiple sources of sampling bias

    USGS Publications Warehouse

    Ruiz-Gutierrez, Viviana; Hooten, Melvin B.; Campbell Grant, Evan H.

    2016-01-01

    Biological monitoring programmes are increasingly relying upon large volumes of citizen-science data to improve the scope and spatial coverage of information, challenging the scientific community to develop design and model-based approaches to improve inference.Recent statistical models in ecology have been developed to accommodate false-negative errors, although current work points to false-positive errors as equally important sources of bias. This is of particular concern for the success of any monitoring programme given that rates as small as 3% could lead to the overestimation of the occurrence of rare events by as much as 50%, and even small false-positive rates can severely bias estimates of occurrence dynamics.We present an integrated, computationally efficient Bayesian hierarchical model to correct for false-positive and false-negative errors in detection/non-detection data. Our model combines independent, auxiliary data sources with field observations to improve the estimation of false-positive rates, when a subset of field observations cannot be validated a posteriori or assumed as perfect. We evaluated the performance of the model across a range of occurrence rates, false-positive and false-negative errors, and quantity of auxiliary data.The model performed well under all simulated scenarios, and we were able to identify critical auxiliary data characteristics which resulted in improved inference. We applied our false-positive model to a large-scale, citizen-science monitoring programme for anurans in the north-eastern United States, using auxiliary data from an experiment designed to estimate false-positive error rates. Not correcting for false-positive rates resulted in biased estimates of occupancy in 4 of the 10 anuran species we analysed, leading to an overestimation of the average number of occupied survey routes by as much as 70%.The framework we present for data collection and analysis is able to efficiently provide reliable inference for occurrence patterns using data from a citizen-science monitoring programme. However, our approach is applicable to data generated by any type of research and monitoring programme, independent of skill level or scale, when effort is placed on obtaining auxiliary information on false-positive rates.

  16. [Predictive factors of contamination in a blood culture with bacterial growth in an Emergency Department].

    PubMed

    Hernández-Bou, S; Trenchs Sainz de la Maza, V; Esquivel Ojeda, J N; Gené Giralt, A; Luaces Cubells, C

    2015-06-01

    The aim of this study is to identify predictive factors of bacterial contamination in positive blood cultures (BC) collected in an emergency department. A prospective, observational and analytical study was conducted on febrile children aged on to 36 months, who had no risk factors of bacterial infection, and had a BC collected in the Emergency Department between November 2011 and October 2013 in which bacterial growth was detected. The potential BC contamination predicting factors analysed were: maximum temperature, time to positivity, initial Gram stain result, white blood cell count, absolute neutrophil count, band count, and C-reactive protein (CRP). Bacteria grew in 169 BC. Thirty (17.8%) were finally considered true positives and 139 (82.2%) false positives. All potential BC contamination predicting factors analysed, except maximum temperature, showed significant differences between true positives and false positives. CRP value, time to positivity, and initial Gram stain result are the best predictors of false positives in BC. The positive predictive values of a CRP value≤30mg/L, BC time to positivity≥16h, and initial Gram stain suggestive of a contaminant in predicting a FP, are 95.1, 96.9 and 97.5%, respectively. When all 3 conditions are applied, their positive predictive value is 100%. Four (8.3%) patients with a false positive BC and discharged to home were revaluated in the Emergency Department. The majority of BC obtained in the Emergency Department that showed positive were finally considered false positives. Initial Gram stain, time to positivity, and CRP results are valuable diagnostic tests in distinguishing between true positives and false positives in BC. The early detection of false positives will allow minimising their negative consequences. Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  17. Reducing false-positive incidental findings with ensemble genotyping and logistic regression based variant filtering methods.

    PubMed

    Hwang, Kyu-Baek; Lee, In-Hee; Park, Jin-Ho; Hambuch, Tina; Choe, Yongjoon; Kim, MinHyeok; Lee, Kyungjoon; Song, Taemin; Neu, Matthew B; Gupta, Neha; Kohane, Isaac S; Green, Robert C; Kong, Sek Won

    2014-08-01

    As whole genome sequencing (WGS) uncovers variants associated with rare and common diseases, an immediate challenge is to minimize false-positive findings due to sequencing and variant calling errors. False positives can be reduced by combining results from orthogonal sequencing methods, but costly. Here, we present variant filtering approaches using logistic regression (LR) and ensemble genotyping to minimize false positives without sacrificing sensitivity. We evaluated the methods using paired WGS datasets of an extended family prepared using two sequencing platforms and a validated set of variants in NA12878. Using LR or ensemble genotyping based filtering, false-negative rates were significantly reduced by 1.1- to 17.8-fold at the same levels of false discovery rates (5.4% for heterozygous and 4.5% for homozygous single nucleotide variants (SNVs); 30.0% for heterozygous and 18.7% for homozygous insertions; 25.2% for heterozygous and 16.6% for homozygous deletions) compared to the filtering based on genotype quality scores. Moreover, ensemble genotyping excluded > 98% (105,080 of 107,167) of false positives while retaining > 95% (897 of 937) of true positives in de novo mutation (DNM) discovery in NA12878, and performed better than a consensus method using two sequencing platforms. Our proposed methods were effective in prioritizing phenotype-associated variants, and an ensemble genotyping would be essential to minimize false-positive DNM candidates. © 2014 WILEY PERIODICALS, INC.

  18. Reducing false positive incidental findings with ensemble genotyping and logistic regression-based variant filtering methods

    PubMed Central

    Hwang, Kyu-Baek; Lee, In-Hee; Park, Jin-Ho; Hambuch, Tina; Choi, Yongjoon; Kim, MinHyeok; Lee, Kyungjoon; Song, Taemin; Neu, Matthew B.; Gupta, Neha; Kohane, Isaac S.; Green, Robert C.; Kong, Sek Won

    2014-01-01

    As whole genome sequencing (WGS) uncovers variants associated with rare and common diseases, an immediate challenge is to minimize false positive findings due to sequencing and variant calling errors. False positives can be reduced by combining results from orthogonal sequencing methods, but costly. Here we present variant filtering approaches using logistic regression (LR) and ensemble genotyping to minimize false positives without sacrificing sensitivity. We evaluated the methods using paired WGS datasets of an extended family prepared using two sequencing platforms and a validated set of variants in NA12878. Using LR or ensemble genotyping based filtering, false negative rates were significantly reduced by 1.1- to 17.8-fold at the same levels of false discovery rates (5.4% for heterozygous and 4.5% for homozygous SNVs; 30.0% for heterozygous and 18.7% for homozygous insertions; 25.2% for heterozygous and 16.6% for homozygous deletions) compared to the filtering based on genotype quality scores. Moreover, ensemble genotyping excluded > 98% (105,080 of 107,167) of false positives while retaining > 95% (897 of 937) of true positives in de novo mutation (DNM) discovery, and performed better than a consensus method using two sequencing platforms. Our proposed methods were effective in prioritizing phenotype-associated variants, and ensemble genotyping would be essential to minimize false positive DNM candidates. PMID:24829188

  19. High luminance monochrome vs. color displays: impact on performance and search

    NASA Astrophysics Data System (ADS)

    Krupinski, Elizabeth A.; Roehrig, Hans; Matsui, Takashi

    2011-03-01

    To determine if diagnostic accuracy and visual search efficiency with a high luminance medical-grade color display are equivalent to a high luminance medical-grade monochrome display. Six radiologists viewed DR chest images, half with a solitary pulmonary nodule and half without. Observers reported whether or not a nodule was present and their confidence in that decision. Total viewing time per image was recorded. On a subset of 15 cases eye-position was recorded. Confidence data were analyzed using MRMC ROC techniques. There was no statistically significant difference (F = 0.0136, p = 0.9078) between color (mean Az = 0.8981, se = 0.0065) and monochrome (mean Az = 0.8945, se = 0.0148) diagnostic performance. Total viewing time per image did not differ significantly (F = 0.392, p = 0.5315) as a function of color (mean = 27.36 sec, sd = 12.95) vs monochrome (mean = 28.04, sd = 14.36) display. There were no significant differences in decision dwell times (true and false, positive and negative) overall for color vs monochrome displays (F = 0.133, p = 0.7154). The true positive (TP) and false positive (FP) decisions were associated with the longest dwell times, the false negatives (FN) with slightly shorter dwell times, and the true negative decisions (TN) with the shortest (F = 50.552, p < 0.0001) and these trends were consistent for both color and monochrome displays. Current color medical-grade displays are suitable for primary diagnostic interpretation in clinical radiology.

  20. The sFlt-1/PlGF ratio associates with prolongation and adverse outcome of pregnancy in women with (suspected) preeclampsia: analysis of a high-risk cohort.

    PubMed

    Saleh, Langeza; Verdonk, Koen; Jan Danser, A H; Steegers, Eric A P; Russcher, Henk; van den Meiracker, Anton H; Visser, Willy

    2016-04-01

    To evaluate the additive value of the sFlt-1/PlGF ratio for diagnosing preeclampsia (PE) and predicting prolongation of pregnancy and adverse outcome in a cohort of women with PE or at high risk of PE. Patients with suspected or confirmed clinical PE were recruited. At time of inclusion blood for measurement of sFlt-1and PlGF was taken. Values were determined after delivery. A cut-off ratio of ≥85 was defined as a positive test. A total of 107 patients were included. Of the patients, 62 (58%) met the clinical criteria of PE at time of blood sampling. In 10% of these patients (n=6) the ratio was <85 (false negative), whereas in 7% (n=3) of patients without clinical PE the ratio was ≥85 (false positive), resulting in positive and negative predictive values of 95% and 88% respectively. One patient with false positive ratio developed superimposed PE and 2 developed gestational hypertension, and adverse outcome occurred in all three. An adverse pregnancy outcome was only encountered in 1 of the 6 patients with a false negative ratio. Using a binary regression model with adjustment for gestational age <34 weeks, the adverse outcome risk was 11 times increased on the basis of clinical PE, and 30 times on the basis of an elevated ratio (P=0.036). The additive value of an increased ratio for diagnosing PE is limited since most patients with clinical PE also have a positive ratio. However, an elevated ratio is superior to the clinical diagnosis of PE for predicting an adverse pregnancy outcome. Furthermore, irrespective of clinical PE, a low ratio is inversely correlated with prolongation of pregnancy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. The problem of false positives and false negatives in violent video game experiments.

    PubMed

    Ferguson, Christopher J

    The problem of false positives and negatives has received considerable attention in behavioral research in recent years. The current paper uses video game violence research as an example of how such issues may develop in a field. Despite decades of research, evidence on whether violent video games (VVGs) contribute to aggression in players has remained mixed. Concerns have been raised in recent years that experiments regarding VVGs may suffer from both "false positives" and "false negatives." The current paper examines this issue in three sets of video game experiments, two sets of video game experiments on aggression and prosocial behaviors identified in meta-analysis, and a third group of recent null studies. Results indicated that studies of VVGs and aggression appear to be particularly prone to false positive results. Studies of VVGs and prosocial behavior, by contrast are heterogeneous and did not demonstrate any indication of false positive results. However, their heterogeneous nature made it difficult to base solid conclusions on them. By contrast, evidence for false negatives in null studies was limited, and little evidence emerged that null studies lacked power in comparison those highlighted in past meta-analyses as evidence for effects. These results are considered in light of issues related to false positives and negatives in behavioral science more broadly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    PubMed Central

    Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M. Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz

    2015-01-01

    Background Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Methodology/Principal Findings Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). Conclusion The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study. PMID:26161864

  3. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    PubMed

    Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz

    2015-01-01

    Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  4. Relevance of cutoff on a 4th generation ELISA performance in the false positive rate during HIV diagnostic in a low HIV prevalence setting.

    PubMed

    Chacón, Lucía; Mateos, María Luisa; Holguín, África

    2017-07-01

    Despite the high specificity of fourth-generation enzyme immunoassays (4th-gen-EIA) for screening during HIV diagnosis, their positive predictive value is low in populations with low HIV prevalence. Thus, screening should be optimized to reduce false positive results. The influence of sample cutoff (S/CO) values by a 4th-gen-EIA with the false positive rate during the routine HIV diagnosis in a low HIV prevalence population was evaluated. A total of 30,201 sera were tested for HIV diagnosis using Abbott Architect ® HIV-Ag/Ab-Combo 4th-gen-EIA at a hospital in Spain during 17 months. Architect S/CO values were recorded, comparing the HIV-1 positive results following Architect interpretation (S/CO≥1) with the final HIV-1 diagnosis by confirmatory tests (line immunoassay, LIA and/or nucleic acid test, NAT). ROC curve was also performed. Among the 30,201 HIV performed tests, 256 (0.85%) were positive according to Architect interpretation (S/CO≥1) but only 229 (0.76%) were definitively HIV-1 positive after LIA and/or NAT. Thus, 27 (10.5%) of 256 samples with S/CO≥1 by Architect were false positive diagnose. The false positive rate decreased when the S/CO ratio increased. All 19 samples with S/CO ≤10 were false positives and all 220 with S/CO>50 true HIV-positives. The optimal S/CO cutoff value provided by ROC curves was 32.7. No false negative results were found. We show that very low S/CO values during HIV-1 screening using Architect can result HIV negative after confirmation by LIA and NAT. The false positive rate is reduced when S/CO increases. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Which Factors Contribute to False-Positive, False-Negative, and Invalid Results in Fetal Fibronectin Testing in Women with Symptoms of Preterm Labor?

    PubMed

    Bruijn, Merel M C; Hermans, Frederik J R; Vis, Jolande Y; Wilms, Femke F; Oudijk, Martijn A; Kwee, Anneke; Porath, Martina M; Oei, Guid; Scheepers, Hubertina C J; Spaanderman, Marc E A; Bloemenkamp, Kitty W M; Haak, Monique C; Bolte, Antoinette C; Vandenbussche, Frank P H A; Woiski, Mallory D; Bax, Caroline J; Cornette, Jérôme M J; Duvekot, Johannes J; Bijvank, Bas W A N I J; van Eyck, Jim; Franssen, Maureen T M; Sollie, Krystyna M; van der Post, Joris A M; Bossuyt, Patrick M M; Kok, Marjolein; Mol, Ben W J; van Baaren, Gert-Jan

    2017-02-01

    Objective  We assessed the influence of external factors on false-positive, false-negative, and invalid fibronectin results in the prediction of spontaneous delivery within 7 days. Methods  We studied symptomatic women between 24 and 34 weeks' gestational age. We performed uni- and multivariable logistic regression to estimate the effect of external factors (vaginal soap, digital examination, transvaginal sonography, sexual intercourse, vaginal bleeding) on the risk of false-positive, false-negative, and invalid results, using spontaneous delivery within 7 days as the outcome. Results  Out of 708 women, 237 (33%) had a false-positive result; none of the factors showed a significant association. Vaginal bleeding increased the proportion of positive fetal fibronectin (fFN) results, but was significantly associated with a lower risk of false-positive test results (odds ratio [OR], 0.22; 95% confidence intervals [CI], 0.12-0.39). Ten women (1%) had a false-negative result. None of the investigated factors was significantly associated with a significantly higher risk of false-negative results. Twenty-one tests (3%) were invalid; only vaginal bleeding showed a significant association (OR, 4.5; 95% CI, 1.7-12). Conclusion  The effect of external factors on the performance of qualitative fFN testing is limited, with vaginal bleeding as the only factor that reduces its validity. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. Life-threatening false alarm rejection in ICU: using the rule-based and multi-channel information fusion method.

    PubMed

    Liu, Chengyu; Zhao, Lina; Tang, Hong; Li, Qiao; Wei, Shoushui; Li, Jianqing

    2016-08-01

    False alarm (FA) rates as high as 86% have been reported in intensive care unit monitors. High FA rates decrease quality of care by slowing staff response times while increasing patient burdens and stresses. In this study, we proposed a rule-based and multi-channel information fusion method for accurately classifying the true or false alarms for five life-threatening arrhythmias: asystole (ASY), extreme bradycardia (EBR), extreme tachycardia (ETC), ventricular tachycardia (VTA) and ventricular flutter/fibrillation (VFB). The proposed method consisted of five steps: (1) signal pre-processing, (2) feature detection and validation, (3) true/false alarm determination for each channel, (4) 'real-time' true/false alarm determination and (5) 'retrospective' true/false alarm determination (if needed). Up to four signal channels, that is, two electrocardiogram signals, one arterial blood pressure and/or one photoplethysmogram signal were included in the analysis. Two events were set for the method validation: event 1 for 'real-time' and event 2 for 'retrospective' alarm classification. The results showed that 100% true positive ratio (i.e. sensitivity) on the training set were obtained for ASY, EBR, ETC and VFB types, and 94% for VTA type, accompanied by the corresponding true negative ratio (i.e. specificity) results of 93%, 81%, 78%, 85% and 50% respectively, resulting in the score values of 96.50, 90.70, 88.89, 92.31 and 64.90, as well as with a final score of 80.57 for event 1 and 79.12 for event 2. For the test set, the proposed method obtained the score of 88.73 for ASY, 77.78 for EBR, 89.92 for ETC, 67.74 for VFB and 61.04 for VTA types, with the final score of 71.68 for event 1 and 75.91 for event 2.

  7. Skin irritation, false positives and the local lymph node assay: a guideline issue?

    PubMed

    Basketter, David A; Kimber, Ian

    2011-10-01

    Since the formal validation and regulatory acceptance of the local lymph node assay (LLNA) there have been commentaries suggesting that the irritant properties of substances can give rise to false positives. As toxicology aspires to progress rapidly towards the age of in vitro alternatives, it is of increasing importance that issues relating to assay selectivity and performance are understood fully, and that true false positive responses are distinguished clearly from those that are simply unpalatable. In the present review, we have focused on whether skin irritation per se is actually a direct cause of true false positive results in the LLNA. The body of published work has been examined critically and considered in relation to our current understanding of the mechanisms of skin irritation and skin sensitisation. From these analyses it is very clear that, of itself, skin irritation is not a cause of false positive results. The corollary is, therefore, that limiting test concentrations in the LLNA for the purpose of avoiding skin irritation may lead, unintentionally, to false negatives. Where a substance is a true false positive in the LLNA, the classic example being sodium lauryl sulphate, explanations for that positivity will have to reach beyond the seductive, but incorrect, recourse to its skin irritation potential. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. Hypertension is strongly associated with false-positive bicycle exercise stress echocardiography testing results.

    PubMed

    Keller, Karsten; Stelzer, Kathrin; Munzel, Thomas; Ostad, Mir Abolfazl

    2016-12-01

    Exercise echocardiography is a reliable routine test in patients with known or suspected coronary artery disease. However, in ∼15% of all patients, stress echocardiography leads to false-positive stress echocardiography results. We aimed to investigate the impact of hypertension on stress echocardiographic results. We performed a retrospective study of patients with suspected or known stable coronary artery disease who underwent a bicycle exercise stress echocardiography. Patients with false-positive stress results were compared with those with appropriate results. 126 patients with suspected or known coronary artery disease were included in this retrospective study. 23 patients showed false-positive stress echocardiography results. Beside comparable age, gender distribution and coronary artery status, hypertension was more prevalent in patients with false-positive stress results (95.7% vs. 67.0%, p = 0.0410). Exercise peak load revealed a borderline-significance with lower loads in patients with false-positive results (100.0 (IQR 75.0/137.5) vs. 125.0 (100.0/150.0) W, p = 0.0601). Patients with false-positive stress results showed higher systolic (2.05 ± 0.69 vs. 1.67 ± 0.39 mmHg/W, p = 0.0193) and diastolic (1.03 ± 0.38 vs. 0.80 ± 0.28 mmHg/W, p = 0.0165) peak blood pressure (BP) per wattage. In a multivariate logistic regression test, hypertension (OR 17.6 [CI 95% 1.9-162.2], p = 0.0115), and systolic (OR 4.12 [1.56-10.89], p = 0.00430) and diastolic (OR 13.74 [2.46-76.83], p = 0.00285) peak BP per wattage, were associated with false-positive exercise results. ROC analysis for systolic and diastolic peak BP levels per wattage showed optimal cut-off values of 1.935mmHg/W and 0.823mmHg/W, indicating false-positive exercise echocardiographic results with AUCs of 0.660 and 0.664, respectively. Hypertension is a risk factor for false-positive stress exercise echocardiographic results in patients with known or suspected coronary artery disease. Presence of hypertension was associated with 17.6-fold elevated risk of false-positive results.

  9. The epidemiology of pertussis in the Australian Capital Territory, 1999 to 2005--epidemics of testing, disease or false positives?

    PubMed

    Wylks, Clare E; Ewald, Ben; Guest, Charles

    2007-12-01

    The increase in pertussis notifications since the 1990s in many countries, including Australia, has been attributed to improved diagnosis. This study aimed to describe the epidemiology of pertussis in the Australian Capital Territory from 1999 to 2005, determine whether the apparent changes could be accounted for by greater recognition and testing, and explore the impact of false positive serology results associated with faulty test kits. The Australian Capital Territory resident notification, laboratory and separation data from 1999 to 2005 were examined and the proportions of positive tests across time periods and age groups compared. Notification rates increased in the years 2000, 2003 and 2005. There was a shift in the age distribution of cases, from children and teenagers in 2000, to teenagers in 2003 and adults in 2005. Testing activity and notification activity were closely related. Comparing the epidemic periods to the preceding inter-epidemic periods, the proportion of positive tests was maintained or increased for all age groups combined and for adults and children (e.g. statistically significant increase from 7.8% to 14.0% in the 2005 epidemic in adults). During each epidemic the proportion of positive tests was statistically significantly higher in the age group with the highest notification activity. Despite similar testing rates in adults in 2003 and 2005, greater disease activity was reported in 2005. Although the numbers were small, polymerase chain reaction and culture positive test results increased in 2003 but not in 2005. The proportion of positive polymerase chain reaction results increased in 2003, providing strong evidence that the apparent epidemic of 2003 was due to a true increase in underlying disease activity. Because of the uncertainty surrounding the timing of the false positive serology results, the study provides weaker support for a true epidemic of pertussis in 2005.

  10. Development of size-selective sampling of Bacillus anthracis surrogate spores from simulated building air intake mixtures for analysis via laser-induced breakdown spectroscopy.

    PubMed

    Gibb-Snyder, Emily; Gullett, Brian; Ryan, Shawn; Oudejans, Lukas; Touati, Abderrahmane

    2006-08-01

    Size-selective sampling of Bacillus anthracis surrogate spores from realistic, common aerosol mixtures was developed for analysis by laser-induced breakdown spectroscopy (LIBS). A two-stage impactor was found to be the preferential sampling technique for LIBS analysis because it was able to concentrate the spores in the mixtures while decreasing the collection of potentially interfering aerosols. Three common spore/aerosol scenarios were evaluated, diesel truck exhaust (to simulate a truck running outside of a building air intake), urban outdoor aerosol (to simulate common building air), and finally a protein aerosol (to simulate either an agent mixture (ricin/anthrax) or a contaminated anthrax sample). Two statistical methods, linear correlation and principal component analysis, were assessed for differentiation of surrogate spore spectra from other common aerosols. Criteria for determining percentages of false positives and false negatives via correlation analysis were evaluated. A single laser shot analysis of approximately 4 percent of the spores in a mixture of 0.75 m(3) urban outdoor air doped with approximately 1.1 x 10(5) spores resulted in a 0.04 proportion of false negatives. For that same sample volume of urban air without spores, the proportion of false positives was 0.08.

  11. False Recognition in Behavioral Variant Frontotemporal Dementia and Alzheimer's Disease-Disinhibition or Amnesia?

    PubMed

    Flanagan, Emma C; Wong, Stephanie; Dutt, Aparna; Tu, Sicong; Bertoux, Maxime; Irish, Muireann; Piguet, Olivier; Rao, Sulakshana; Hodges, John R; Ghosh, Amitabha; Hornberger, Michael

    2016-01-01

    Episodic memory recall processes in Alzheimer's disease (AD) and behavioral variant frontotemporal dementia (bvFTD) can be similarly impaired, whereas recognition performance is more variable. A potential reason for this variability could be false-positive errors made on recognition trials and whether these errors are due to amnesia per se or a general over-endorsement of recognition items regardless of memory. The current study addressed this issue by analysing recognition performance on the Rey Auditory Verbal Learning Test (RAVLT) in 39 bvFTD, 77 AD and 61 control participants from two centers (India, Australia), as well as disinhibition assessed using the Hayling test. Whereas both AD and bvFTD patients were comparably impaired on delayed recall, bvFTD patients showed intact recognition performance in terms of the number of correct hits. However, both patient groups endorsed significantly more false-positives than controls, and bvFTD and AD patients scored equally poorly on a sensitivity index (correct hits-false-positives). Furthermore, measures of disinhibition were significantly associated with false positives in both groups, with a stronger relationship with false-positives in bvFTD. Voxel-based morphometry analyses revealed similar neural correlates of false positive endorsement across bvFTD and AD, with both patient groups showing involvement of prefrontal and Papez circuitry regions, such as medial temporal and thalamic regions, and a DTI analysis detected an emerging but non-significant trend between false positives and decreased fornix integrity in bvFTD only. These findings suggest that false-positive errors on recognition tests relate to similar mechanisms in bvFTD and AD, reflecting deficits in episodic memory processes and disinhibition. These findings highlight that current memory tests are not sufficient to accurately distinguish between bvFTD and AD patients.

  12. Hog Charm II tetracycline test screening results compared with a liquid chromatography tandem mass spectrometry 10-μg/kg method.

    PubMed

    Salter, Robert; Holmes, Steven; Legg, David; Coble, Joel; George, Bruce

    2012-02-01

    Pork tissue samples that tested positive and negative by the Charm II tetracycline test screening method in the slaughter plant laboratory were tested with the modified AOAC International liquid chromatography tandem mass spectrometry (LC-MS-MS) method 995.09 to determine the predictive value of the screening method at detecting total tetracyclines at 10 μg/kg of tissue, in compliance with Russian import regulations. There were 218 presumptive-positive tetracycline samples of 4,195 randomly tested hogs. Of these screening test positive samples, 83% (182) were positive, >10 μg/kg by LC-MS-MS; 12.8% (28) were false violative, greater than limit of detection (LOD) but <10 μg/kg; and 4.2% (8) were not detected at the LC-MS-MS LOD. The 36 false-violative and not-detected samples represent 1% of the total samples screened. Twenty-seven of 30 randomly selected tetracycline screening negative samples tested below the LC-MS-MS LOD, and 3 samples tested <3 μg/kg chlortetracycline. Results indicate that the Charm II tetracycline test is effective at predicting hogs containing >10 μg/kg total tetracyclines in compliance with Russian import regulations.

  13. Creatine transporter deficiency: prevalence among patients with mental retardation and pitfalls in metabolite screening.

    PubMed

    Arias, Angela; Corbella, Marc; Fons, Carmen; Sempere, Angela; García-Villoria, Judit; Ormazabal, Aida; Poo, Pilar; Pineda, Mercé; Vilaseca, María Antonia; Campistol, Jaume; Briones, Paz; Pàmpols, Teresa; Salomons, Gajja S; Ribes, Antonia; Artuch, Rafael

    2007-11-01

    To report the prevalence of creatine transporter deficiency in males with mental retardation and to study whether a protein-rich food intake might be a potential diagnostic pitfall. We determined creatine/creatinine ratio in urine samples from 1600 unrelated male patients with mental retardation and/or autism. Urine creatine was analyzed by HPLC-MS/MS. Thirty-three of 1600 cases showed increased urine creatine/creatinine ratio. Four out of these thirty-three cases were definitively diagnosed with creatine transporter deficiency, while the other 29 were false positive results. Significantly higher values were observed for urine Cr/Crn ratio in healthy volunteers after a meal based on beef or oily fish as compared to eggs, pasta or salad (Wilcoxon test: p<0.005). False positive results may be observed in biochemical screening for creatine transporter deficiency, and they may be due to intake of meals rich in creatine prior to urine samples analysis.

  14. False-positive tangible outcomes of functional analyses.

    PubMed

    Rooker, Griffin W; Iwata, Brian A; Harper, Jill M; Fahmie, Tara A; Camp, Erin M

    2011-01-01

    Functional analysis (FA) methodology is the most precise method for identifying variables that maintain problem behavior. Occasionally, however, results of an FA may be influenced by idiosyncratic sensitivity to aspects of the assessment conditions. For example, data from several studies suggest that inclusion of a tangible condition during an FA may be prone to a false-positive outcome, although the extent to which tangible reinforcement routinely produces such outcomes is unknown. We examined susceptibility to tangible reinforcement by determining whether a new response was acquired more readily when exposed to a tangible contingency relative to others commonly used in an FA (Study 1), and whether problem behavior known not to have a social function nevertheless emerged when exposed to tangible reinforcement (Study 2). Results indicated that inclusion of items in the tangible condition should be done with care and that selection should be based on those items typically found in the individual's environment.

  15. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    PubMed

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  16. Noninvasive Electromagnetic Detection of Bladder Cancer

    PubMed Central

    Cormio, Luigi; Vedruccio, Clarbruno; Leucci, Giorgio; Massenio, Paolo; Di Fino, Giuseppe; Cavaliere, Vincenzo; Carrieri, Giuseppe

    2014-01-01

    Objectives. Normal and neoplastic human tissues have different electromagnetic properties. This study aimed to determine the diagnostic accuracy of noninvasive electromagnetic detection of bladder cancer (BC) by the tissue-resonance interaction method (TRIM-prob). Patients and Methods. Consecutive patients were referred for cystoscopy because of (i) microscopic or gross hematuria and/or irritative voiding symptoms and (ii) bladder ultrasounds and urinary cytology findings negative or just suspicious of malignancy. Patients were first submitted to TRIM-prob bladder scanning by a single investigator and then to cystoscopy by another investigator blind to TRIM-prob data. Results. In 125 evaluated patients cystoscopy was positive for BC in 47 and negative in the remaining 78; conversely, TRIM-prob bladder scanning was positive for BC in 53 and negative in 72. In particular, TRIM-prob scanning yielded 7 false positives and only one false negative; therefore, its overall sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.9%, 89.9%, 86.8%, 98.6%, and 93.6%, respectively. Conclusions. TRIM-prob bladder scanning was a simple and quite accurate method for non-invasive electromagnetic detection of BC. If the elevated positive and negative predictive values will be replicated in further well-designed studies, it could be used to screen asymptomatic patients at high risk of BC. PMID:24563795

  17. How Reliable Is the Alpha-defensin Immunoassay Test for Diagnosing Periprosthetic Joint Infection? A Prospective Study.

    PubMed

    Bonanzinga, Tommaso; Zahar, Akos; Dütsch, Michael; Lausmann, Christian; Kendoff, Daniel; Gehrke, Thorsten

    2017-02-01

    A key issue in the treatment of periprosthetic joint infection (PJI) is the correct diagnosis. The main problem is lack of diagnostic tools able to diagnose a PJI with high accuracy. Alpha-defensin has been proposed as a possible solution, but in the current literature, there is a lack of independent validation. We performed a prospective study to determine (1) what is the sensitivity, specificity, and positive and the negative predictive values of the alpha-defensin immunoassay test in diagnosing PJI; and (2) which clinical features may be responsible for false-positive and false-negative results? Preoperative aspiration was performed in all patients presenting with a painful hip/knee arthroplasty, including both primary and revision implants. Metallosis, other inflammatory comorbidities, and previous/concomitant antibiotic therapy were not considered as exclusion criteria. An inadequate amount of synovial fluid for culture was an exclusion criterion. A total of 156 patients (65 knees, 91 hips) were included in this prospective study. At the time of revision, synovial fluid samples were taken to perform the alpha-defensin assay. During surgical débridement of tissue, samples for cultures and histologic evaluation were taken, and samples were cultured until positive or until negative at 14 days. A diagnosis of PJI was confirmed in 29 patients according to the International Consensus Group on PJI. The sensitivity of the alpha-defensin immunoassay was 97% (95% confidence interval [CI], 92%-99%), the specificity was 97% (95% CI, 92%-99%), the positive predictive value was 88% (95% CI, 81%-92%), and the negative predictive value was 99% (95% CI, 96%-99%). Among four false-positive patients, two had metallosis and one had polyethylene wear. The false-negative case presented with a draining sinus, and intraoperative cultures were also negative. Alpha-defensin assay appears to be a reliable test, but followup evaluation is needed to estimate longer term performance of the test. The authors believe that alpha-defensin has demonstrated itself to be sufficiently robust that PJI diagnostic criteria now should include this test. Future studies are needed to compare the differences among the diagnostic capability of the available tests, in particular when metallosis is present, because metallosis may predispose the test to a false-positive result. Level I, diagnostic study.

  18. Relapse surveillance in AFP-positive hepatoblastoma: re-evaluating the role of imaging.

    PubMed

    Rojas, Yesenia; Guillerman, R Paul; Zhang, Wei; Vasudevan, Sanjeev A; Nuchtern, Jed G; Thompson, Patrick A

    2014-10-01

    Children with hepatoblastoma routinely undergo repetitive surveillance imaging, with CT scans for several years after therapy, increasing the risk of radiation-induced cancer. The purpose of this study was to determine the utility of surveillance CT scans compared to serum alpha-fetoprotein (AFP) levels for the detection of hepatoblastoma relapse. This was a retrospective study of all children diagnosed with AFP-positive hepatoblastoma from 2001 to 2011 at a single institution. Twenty-six children with hepatoblastoma were identified, with a mean age at diagnosis of 2 years 4 months (range 3 months to 11 years). Mean AFP level at diagnosis was 132,732 ng/ml (range 172.8-572,613 ng/ml). Five of the 26 children had hepatoblastoma relapse. A total of 105 imaging exams were performed following completion of therapy; 88 (84%) CT, 8 (8%) MRI, 5 (5%) US and 4 (4%) FDG PET/CT exams. A total of 288 alpha-fetoprotein levels were drawn, with a mean of 11 per child. The AFP level was elevated in all recurrences and no relapses were detected by imaging before AFP elevation. Two false-positive AFP levels and 15 false-positive imaging exams were detected. AFP elevation was found to be significantly more specific than PET/CT and CT imaging at detecting relapse. We recommend using serial serum AFP levels as the preferred method of surveillance in children with AFP-positive hepatoblastoma, reserving imaging for the early postoperative period, for children at high risk of relapse, and for determination of the anatomical site of clinically suspected recurrence. Given the small size of this preliminary study, validation in a larger patient population is warranted.

  19. Diurnal rhythm and concordance between objective and subjective hot flashes: the Hilo Women's Health Study.

    PubMed

    Sievert, Lynnette L; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E

    2010-01-01

    The aims of this study were to test for a diurnal pattern in hot flashes in a multiethnic population living in a hot, humid environment and to examine the rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Study participants aged 45 to 55 years were recruited from the general population of Hilo, HI. Women wore a Biolog hot flash monitor (UFI, Morro Bay, CA), kept a diary for 24 hours, and also participated in 3-hour laboratory measures (n = 199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true-positive readings. Subjective hot flashes were considered the standard for computing false-positive and false-negative readings. True-positive, false-positive, and false-negative readings were compared across ethnic groups by chi analyses. Frequencies of sternal, nuchal, and subjective hot flashes peaked at 1500 +/- 1 hours with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true-positive measures, but nonsternal electrodes picked up more false-positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true-positive or false-positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false-negative measures). The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo were similar to results from more temperate environments. Lack of variation in sternal versus nonsternal measures and in true-positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns.

  20. Diurnal rhythm and concordance between objective and subjective hot flashes: The Hilo Women’s Health Study

    PubMed Central

    Sievert, Lynnette L.; Reza, Angela; Mills, Phoebe; Morrison, Lynn; Rahberg, Nichole; Goodloe, Amber; Sutherland, Michael; Brown, Daniel E.

    2010-01-01

    Objective To test for a diurnal pattern in hot flashes in a multi-ethnic population living in a hot, humid environment. To examine rates of concordance between objective and subjective measures of hot flashes using ambulatory and laboratory measures. Methods Study participants aged 45–55 were recruited from the general population of Hilo, Hawaii. Women wore a Biolog hot flash monitor, kept a diary for 24-hours, and also participated in 3-hour laboratory measures (n=199). Diurnal patterns were assessed using polynomial regression. For each woman, objectively recorded hot flashes that matched subjective experience were treated as true positive readings. Subjective hot flashes were considered the standard for computing false positive and false negative readings. True positive, false positive, and false negative readings were compared across ethnic groups by chi-square analyses. Results Frequencies of sternal, nuchal and subjective hot flashes peaked at 15:00 ± 1 hour with no difference by ethnicity. Laboratory results supported the pattern seen in ambulatory monitoring. Sternal and nuchal monitoring showed the same frequency of true positive measures, but non-sternal electrodes picked up more false positive readings. Laboratory monitoring showed very low frequencies of false negatives. There were no ethnic differences in the frequency of true positive or false positive measures. Women of European descent were more likely to report hot flashes that were not objectively demonstrated (false negative measures). Conclusions The diurnal pattern and peak in hot flash occurrence in the hot humid environment of Hilo was similar to results from more temperate environments. Lack of variation in sternal vs. non-sternal measures, and in true positive measures across ethnicities suggests no appreciable effect of population variation in sweating patterns. PMID:20220538

  1. Ignoring Intermarker Linkage Disequilibrium Induces False-Positive Evidence of Linkage for Consanguineous Pedigrees when Genotype Data Is Missing for Any Pedigree Member

    PubMed Central

    Li, Bingshan; Leal, Suzanne M.

    2008-01-01

    Missing genotype data can increase false-positive evidence for linkage when either parametric or nonparametric analysis is carried out ignoring intermarker linkage disequilibrium (LD). Previously it was demonstrated by Huang et al. [1] that no bias occurs in this situation for affected sib-pairs with unrelated parents when either both parents are genotyped or genotype data is available for two additional unaffected siblings when parental genotypes are missing. However, this is not the case for autosomal recessive consanguineous pedigrees, where missing genotype data for any pedigree member within a consanguinity loop can increase false-positive evidence of linkage. False-positive evidence for linkage is further increased when cryptic consanguinity is present. The amount of false-positive evidence for linkage, and which family members aid in its reduction, is highly dependent on which family members are genotyped. When parental genotype data is available, the false-positive evidence for linkage is usually not as strong as when parental genotype data is unavailable. For a pedigree with an affected proband whose first-cousin parents have been genotyped, further reduction in the false-positive evidence of linkage can be obtained by including genotype data from additional affected siblings of the proband or genotype data from the proband's sibling-grandparents. For the situation, when parental genotypes are unavailable, false-positive evidence for linkage can be reduced by including genotype data from either unaffected siblings of the proband or the proband's married-in-grandparents in the analysis. PMID:18073490

  2. Biological false-positive venereal disease research laboratory test in cerebrospinal fluid in the diagnosis of neurosyphilis - a case-control study.

    PubMed

    Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L

    2018-03-01

    There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.

  3. Field testing Diorhabda elongata (Coleoptera:Chrysomelidae) from Crete, Greece to assess potential impact to non-target native California plants in the genus Frankenia

    USDA-ARS?s Scientific Manuscript database

    When laboratory host specificity tests on weed biological control agents produce ambiguous results or are suspected of producing false positives, field cage or open field tests can be utilized in an attempt to determine the true ecological host range of the agent. The leaf beetle Diorhabda elongata ...

  4. 17 CFR 240.15c3-5 - Risk management controls for brokers or dealers with market access.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... determining that such customer, based on its position in the transaction and relationship with an ultimate... 17 Commodity and Securities Exchanges 3 2011-04-01 2011-04-01 false Risk management controls for... Markets § 240.15c3-5 Risk management controls for brokers or dealers with market access. (a) For the...

  5. 17 CFR 240.15c3-5 - Risk management controls for brokers or dealers with market access.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... determining that such customer, based on its position in the transaction and relationship with an ultimate... 17 Commodity and Securities Exchanges 3 2012-04-01 2012-04-01 false Risk management controls for... Markets § 240.15c3-5 Risk management controls for brokers or dealers with market access. (a) For the...

  6. Sequence fingerprints distinguish erroneous from correct predictions of intrinsically disordered protein regions.

    PubMed

    Saravanan, Konda Mani; Dunker, A Keith; Krishnaswamy, Sankaran

    2017-12-27

    More than 60 prediction methods for intrinsically disordered proteins (IDPs) have been developed over the years, many of which are accessible on the World Wide Web. Nearly, all of these predictors give balanced accuracies in the ~65%-~80% range. Since predictors are not perfect, further studies are required to uncover the role of amino acid residues in native IDP as compared to predicted IDP regions. In the present work, we make use of sequences of 100% predicted IDP regions, false positive disorder predictions, and experimentally determined IDP regions to distinguish the characteristics of native versus predicted IDP regions. A higher occurrence of asparagine is observed in sequences of native IDP regions but not in sequences of false positive predictions of IDP regions. The occurrences of certain combinations of amino acids at the pentapeptide level provide a distinguishing feature in the IDPs with respect to globular proteins. The distinguishing features presented in this paper provide insights into the sequence fingerprints of amino acid residues in experimentally determined as compared to predicted IDP regions. These observations and additional work along these lines should enable the development of improvements in the accuracy of disorder prediction algorithm.

  7. A soft kinetic data structure for lesion border detection.

    PubMed

    Kockara, Sinan; Mete, Mutlu; Yip, Vincent; Lee, Brendan; Aydin, Kemal

    2010-06-15

    The medical imaging and image processing techniques, ranging from microscopic to macroscopic, has become one of the main components of diagnostic procedures to assist dermatologists in their medical decision-making processes. Computer-aided segmentation and border detection on dermoscopic images is one of the core components of diagnostic procedures and therapeutic interventions for skin cancer. Automated assessment tools for dermoscopic images have become an important research field mainly because of inter- and intra-observer variations in human interpretations. In this study, a novel approach-graph spanner-for automatic border detection in dermoscopic images is proposed. In this approach, a proximity graph representation of dermoscopic images in order to detect regions and borders in skin lesion is presented. Graph spanner approach is examined on a set of 100 dermoscopic images whose manually drawn borders by a dermatologist are used as the ground truth. Error rates, false positives and false negatives along with true positives and true negatives are quantified by digitally comparing results with manually determined borders from a dermatologist. The results show that the highest precision and recall rates obtained to determine lesion boundaries are 100%. However, accuracy of assessment averages out at 97.72% and borders errors' mean is 2.28% for whole dataset.

  8. 77 FR 48045 - Supplemental Nutrition Assistance Program: Disqualified Recipient Reporting and Computer Matching...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-13

    ... false positive match rate of 10 percent. Making the match mandatory for the States who did not perform... number of prisoners from 1995 to 2013 and assumed a 10 percent false positive match rate. Finally, we... matches are false positives. We estimate that mandatory matches at certification will identify an...

  9. [Quality assurance of rapid on-site evaluation of CT-guided fine-needle aspiration cytology of lung nodules].

    PubMed

    Bak, Mihály; Hidvégi, Judit; Andi, Judit; Bahéry, Mária; Kovács, Eszter; Schneider, Ferenc; Kostic, Szilárd; Rényi-Vámos, Ferenc; Szőke, János; Nyári, Tibor; Gődény, Mária; Kásler, Miklós

    2013-01-06

    The methods available for the diagnosis of lung cancer include radiologic, cytologic and pathologic procedures. The aim of this study was to determine the quality assurance of CT guided fine needle aspiration cytology of lung nodules. Cytology results were rated to 4 categories (positive; suspicious; negative; not representative). All cytology reports were compared with the final histology diagnosis. A total of 128 patients underwent CT-guided percutaneous fine-needle aspiration biopsy cytology (63 males; 65 females; mean age 62.8 years). Smears were adequate in 99 cases and inadequate in 29 cases. The average diameter of the nodules was 3.28 cm. Thirty three (25.6%) of the cases were histologically verified and 2 falsely negative and 2 falsely positive cases were detected. The sensitivity and the positive predictive value were 88.8% and 88.8%, respectively. Pneumothorax developed in 7 (5.4%) cases. These results suggest that CT-guided transthoracic fine needle aspiration cytology has a high diagnostic accuracy and an acceptable complication rate. The auditing valves of the results meet the proposed threshold values.

  10. High-frequency (8 to 16 kHz) reference thresholds and intrasubject threshold variability relative to ototoxicity criteria using a Sennheiser HDA 200 earphone.

    PubMed

    Frank, T

    2001-04-01

    The first purpose of this study was to determine high-frequency (8 to 16 kHz) thresholds for standardizing reference equivalent threshold sound pressure levels (RETSPLs) for a Sennheiser HDA 200 earphone. The second and perhaps more important purpose of this study was to determine whether repeated high-frequency thresholds using a Sennheiser HDA 200 earphone had a lower intrasubject threshold variability than the ASHA 1994 significant threshold shift criteria for ototoxicity. High-frequency thresholds (8 to 16 kHz) were obtained for 100 (50 male, 50 female) normally hearing (0.25 to 8 kHz) young adults (mean age of 21.2 yr) in four separate test sessions using a Sennheiser HDA 200 earphone. The mean and median high-frequency thresholds were similar for each test session and increased as frequency increased. At each frequency, the high-frequency thresholds were not significantly (p > 0.05) different for gender, test ear, or test session. The median thresholds at each frequency were similar to the 1998 interim ISO RETSPLs; however, large standard deviations and wide threshold distributions indicated very high intersubject threshold variability, especially at 14 and 16 kHz. Threshold repeatability was determined by finding the threshold differences between each possible test session comparison (N = 6). About 98% of all of the threshold differences were within a clinically acceptable range of +/-10 dB from 8 to 14 kHz. The threshold differences between each subject's second, third, and fourth minus their first test session were also found to determine whether intrasubject threshold variability was less than the ASHA 1994 criteria for determining a significant threshold shift due to ototoxicity. The results indicated a false-positive rate of 0% for a threshold shift > or = 20 dB at any frequency and a false-positive rate of 2% for a threshold shift >10 dB at two consecutive frequencies. This study verified that the output of high-frequency audiometers at 0 dB HL using Sennheiser HDA 200 earphones should equal the 1998 interim ISO RETSPLs from 8 to 16 kHz. Further, because the differences between repeated thresholds were well within +/-10 dB and had an extremely low false-positive rate in reference to the ASHA 1994 criteria for a significant threshold shift due to ototoxicity, a Sennheiser HDA 200 earphone can be used for serial monitoring to determine whether significant high-frequency threshold shifts have occurred for patients receiving potentially ototoxic drug therapy.

  11. Comparison study of the rates of manual peripheral blood smear review from 3 automated hematology analyzers, Unicel DxH 800, ADVIA 2120i, and XE 2100, using international consensus group guidelines.

    PubMed

    Kim, Sue Jung; Kim, Yoonjung; Shin, Saeam; Song, Jaewoo; Choi, Jong Rak

    2012-11-01

    In the clinical laboratory, it is important both to reduce the number of peripheral blood slide reviews to save time and money and to avoid reporting false results. To determine differences in the slide review rates of 3 widely used automated hematologic analyzers, the Unicel DxH 800 (Beckman Coulter Inc, Fullerton, California), ADVIA 2120i (Siemens Diagnostics, Tarrytown, New York), and XE 2100 (Sysmex, Kobe, Japan), using International Consensus Group for Hematology Review guidelines. A total of 1485 samples were tested, and 300 were manually reviewed. Slide review rates, sensitivity, specificity, and false-positive and false-negative rates were estimated using consensus group rules and compared using χ(2) tests, Fisher exact tests, or generalized estimating equations. Unicel DxH 800, ADVIA 2120i, and XE 2100 showed 22.8%, 20.2%, and 28.6% slide review rates; 14.3%, 14.3%, and 9.7% false-negative rates; and 13.7, 11.3%, and 17.3% false-positive rates, respectively. All analyzers showed significantly higher false-negative rates than that of the consensus group (2.9%). False-negative rates were higher than the recommended levels. Among 3 automated hematologic analyzers, XE 2100 showed the highest rate of slide review. Because the present study clearly shows that the slide review rates have distinct characteristics among the studied analyzers, each individual laboratory should consider selecting the most appropriate analyzer according to clinical characteristics. Analyzers with high sensitivity may be advantageous in outpatient settings for screening patients, whereas analyzers with high specificity may be beneficial in inpatient settings for efficient patient care.

  12. Hydrogen breath test in schoolchildren.

    PubMed Central

    Douwes, A C; Schaap, C; van der Klei-van Moorsel, J M

    1985-01-01

    The frequency of negative hydrogen breath tests due to colonic bacterial flora which are unable to produce hydrogen was determined after oral lactulose challenge in 98 healthy Dutch schoolchildren. There was a negative result in 9.2%. The probability of a false normal lactose breath test (1:77) was calculated from these results together with those from a separate group of children with lactose malabsorption (also determined by hydrogen breath test). A study of siblings and mothers of subjects with a negative breath test did not show familial clustering of this condition. Faecal incubation tests with various sugars showed an increase in breath hydrogen greater than 100 parts per million in those with a positive breath test while subjects with a negative breath test also had a negative faecal incubation test. The frequency of a false negative hydrogen breath test was higher than previously reported, but this does not affect the superiority of this method of testing over the conventional blood glucose determination. PMID:4004310

  13. Shear-wave elastography in the diagnosis of solid breast masses: what leads to false-negative or false-positive results?

    PubMed

    Yoon, Jung Hyun; Jung, Hae Kyoung; Lee, Jong Tae; Ko, Kyung Hee

    2013-09-01

    To investigate the factors that have an effect on false-positive or false-negative shear-wave elastography (SWE) results in solid breast masses. From June to December 2012, 222 breast lesions of 199 consecutive women (mean age: 45.3 ± 10.1 years; range, 21 to 88 years) who had been scheduled for biopsy or surgical excision were included. Greyscale ultrasound and SWE were performed in all women before biopsy. Final ultrasound assessments and SWE parameters (pattern classification and maximum elasticity) were recorded and compared with histopathology results. Patient and lesion factors in the 'true' and 'false' groups were compared. Of the 222 masses, 175 (78.8 %) were benign, and 47 (21.2 %) were malignant. False-positive rates of benign masses were significantly higher than false-negative rates of malignancy in SWE patterns, 36.6 % to 6.4 % (P < 0.001). Among both benign and malignant masses, factors showing significance among false SWE features were lesion size, breast thickness and lesion depth (all P < 0.05). All 47 malignant breast masses had SWE images of good quality. False SWE features were more significantly seen in benign masses. Lesion size, breast thickness and lesion depth have significance in producing false results, and this needs consideration in SWE image acquisition. • Shear-wave elastography (SWE) is widely used during breast imaging • At SWE, false-positive rates were significantly higher than false-negative rates • Larger size, breast thickness, depth and fair quality influences false-positive SWE features • Smaller size, larger breast thickness and depth influences false-negative SWE features.

  14. Sensitivity of fetal RHD screening for safe guidance of targeted anti-D immunoglobulin prophylaxis: prospective cohort study of a nationwide programme in the Netherlands.

    PubMed

    de Haas, Masja; Thurik, Florentine F; van der Ploeg, Catharina P B; Veldhuisen, Barbera; Hirschberg, Hoang; Soussan, Aicha Ait; Woortmeijer, Heleen; Abbink, Frithjofna; Page-Christiaens, Godelieve C M L; Scheffer, Peter G; Ellen van der Schoot, C

    2016-11-07

     To determine the accuracy of non-invasive fetal testing for the RHD gene in week 27 of pregnancy as part of an antenatal screening programme to restrict anti-D immunoglobulin use to women carrying a child positive for RHD DESIGN:  Prospectively monitoring of fetal RHD testing accuracy compared with serological cord blood typing on introduction of the test. Fetal RHD testing was performed with a duplex real time quantitative polymerase chain reaction, with cell-free fetal DNA isolated from 1 mL of maternal plasma The study period was between 4 July 2011 and 7 October 2012. The proportion of women participating in screening was determined.  Nationwide screening programme, the Netherlands. Tests are performed in a centralised setting.  25 789 RhD negative pregnant women.  Sensitivity, specificity, false negative rate, and false positive rate of fetal RHD testing compared with serological cord blood typing; proportion of technical failures; and compliance to the screening programme.  A fetal RHD test result and serological cord blood result were available for 25 789 pregnancies. Sensitivity for detection of fetal RHD was 99.94% (95% confidence interval 99.89% to 99.97%) and specificity was 97.74% (97.43% to 98.02%). Nine false negative results for fetal RHD testing were registered (0.03%, 95% confidence interval 0.01% to 0.06%). In two cases these were due to technical failures. False positive fetal RHD testing results were registered for 225 samples (0.87%, 0.76% to 0.99%). Weak RhD expression was shown in 22 of these cases, justifying anti-D immunoglobulin use. The negative and positive predictive values were 99.91% (95% confidence interval 99.82% to 99.95%) and 98.60% (98.40% to 98.77%), respectively. More than 98% of the women participated in the screening programme.  Fetal RHD testing in week 27 of pregnancy as part of a national antenatal screening programme is highly reliable and can be used to target both antenatal and postnatal anti-D immunoglobulin use. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications.

    PubMed

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; den Heeten, Gerard; Karssemeijer, Nico

    2016-04-01

    In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists' detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8-1.0 were significantly different between the system without BACs removal and the system with BACs removal, 0.129 ± 0.009 versus 0.144 ± 0.008 (p<0.05), respectively. Additionally, the sensitivity at one false positive per 50 cases and one false positive per 25 cases increased as well, 37% versus 51% (p<0.05) and 58% versus 67% (p<0.05) sensitivity, respectively. Additionally, the CADe system with BACs removal reduces the number of false positives per case by 29% on average. The same sensitivity at one false positive per 50 cases in the CADe system without BACs removal can be achieved at one false positive per 80 cases in the CADe system with BACs removal. By using dedicated algorithms to detect and remove breast arterial calcifications, the performance of CADe systems can be improved, in particular, at false positive rates representative for operating points used in screening.

  16. Presymptomatic Diagnosis of Spinal Muscular Atrophy Through Newborn Screening.

    PubMed

    Chien, Yin-Hsiu; Chiang, Shu-Chuan; Weng, Wen-Chin; Lee, Ni-Chung; Lin, Ching-Jie; Hsieh, Wu-Shiun; Lee, Wang-Tso; Jong, Yuh-Jyh; Ko, Tsang-Ming; Hwu, Wuh-Liang

    2017-11-01

    To demonstrate the feasibility of presymptomatic diagnosis of spinal muscular atrophy (SMA) through newborn screening (NBS). We performed a screening trial to assess all newborns who underwent routine newborn metabolic screening at the National Taiwan University Hospital newborn screening center between November 2014 and September 2016. A real-time polymerase chain reaction (RT-PCR) genotyping assay for the SMN1/SMN2 intron 7 c.888+100A/G polymorphism was performed to detect homozygous SMN1 deletion using dried blood spot (DBS) samples. Then the exon 7 c.840C>T mutation and SMN2 copy number were determined by both droplet digital PCR (ddPCR) using the original screening DBS and multiplex ligation-dependent probe amplification (MLPA) using a whole blood sample. Of the 120 267 newborns, 15 tested positive according to the RT-PCR assay. The DBS ddPCR assay excluded 8 false-positives, and the other 7 patients were confirmed by the MLPA assay. Inclusion of the second-tier DBS ddPCR screening assay resulted in a positive prediction value of 100%. The incidence of SMA was 1 in 17 181 (95% CI, 1 in 8323 to 1 in 35 468). Two of the 3 patients with 2 copies of SMN2 and all 4 patients with 3 or 4 copies of SMN2 were asymptomatic at the time of diagnosis. Five of the 8 false-positives were caused by intragenic recombination between SMN1 and SMN2. Newborn screening can detect patients affected by SMA before symptom onset and enable early therapeutic intervention. A combination of a RT-PCR and a second-tier ddPCR can accurately diagnose SMA from DBS samples with no false-positives. ClinicalTrials.gov NCT02123186. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Effects of depressive disorder on false memory for emotional information.

    PubMed

    Yeh, Zai-Ting; Hua, Mau-Sun

    2009-01-01

    This study explored with a false memory paradigm whether (1) depressed patients revealed more false memories and (2) whether more negative false than positive false recognition existed in subjects with depressive disorders. Thirty-two patients suffering from a major depressive episode (DSM-IV criteria), and 30 age- and education-matched normal control subjects participated in this study. After the presentation of a list of positive, negative, and neutral association items in the learning phase, subjects were asked to give a yes/no response in the recognition phase. They were also asked to rate 81 recognition items with emotional valence scores. The results revealed more negative false memories in the clinical depression group than in the normal control group; however, we did not find more negative false memories than positive ones in patients. When compared with the normal group, a more conservative response criterion for positive items was evident in patient groups. It was also found that when compared with the normal group, the subjects in the depression group perceived the positive items as less positive. On the basis of present results, it is suggested that depressed subjects judged the emotional information with criteria different from normal individuals, and patients' emotional memory intensity is attenuated by their mood.

  18. A Retrospective Analysis of Urine Drugs of Abuse Immunoassay True Positive Rates at a National Reference Laboratory.

    PubMed

    Johnson-Davis, Kamisha L; Sadler, Aaron J; Genzen, Jonathan R

    2016-03-01

    Urine drug screens are commonly performed to identify drug use or monitor adherence to drug therapy. The purpose of this retrospective study was to evaluate the true positive and false positive rates of one of our in-house urine drug screen panels. The urine drugs of abuse panel studied consists of screening by immunoassay then positive immunoassay results were confirmed by mass spectrometry. Reagents from Syva and Microgenics were used for the immunoassay screen. The screen was performed on a Beckman AU5810 random access automated clinical analyzer. The percent of true positives for each immunoassay was determined. Agreement with previously validated GC-MS or LC-MS-MS confirmatory methods was also evaluated. There were 8,825 de-identified screening results for each of the drugs in the panel, except for alcohol (N = 2,296). The percent of samples that screened positive were: 10.0% for amphetamine/methamphetamine/3,4-methylenedioxy-methamphetamine (MDMA), 12.8% for benzodiazepines, 43.7% for opiates (including oxycodone) and 20.3% for tetrahydrocannabinol (THC). The false positive rate for amphetamine/methamphetamine was ∼14%, ∼34% for opiates (excluding oxycodone), 25% for propoxyphene and 100% for phencyclidine and MDMA immunoassays. Based on the results from this retrospective study, the true positive rate for THC drug use among adults were similar to the rate of illicit drug use in young adults from the 2013 National Survey; however, our positivity rate for cocaine was higher than the National Survey. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. The efficacy and cost of alternative strategies for systematic screening for type 2 diabetes in the U.S. population 45-74 years of age.

    PubMed

    Johnson, Susan L; Tabaei, Bahman P; Herman, William H

    2005-02-01

    To simulate the outcomes of alternative strategies for screening the U.S. population 45-74 years of age for type 2 diabetes. We simulated screening with random plasma glucose (RPG) and cut points of 100, 130, and 160 mg/dl and a multivariate equation including RPG and other variables. Over 15 years, we simulated screening at intervals of 1, 3, and 5 years. All positive screening tests were followed by a diagnostic fasting plasma glucose or an oral glucose tolerance test. Outcomes include the numbers of false-negative, true-positive, and false-positive screening tests and the direct and indirect costs. At year 15, screening every 3 years with an RPG cut point of 100 mg/dl left 0.2 million false negatives, an RPG of 130 mg/dl or the equation left 1.3 million false negatives, and an RPG of 160 mg/dl left 2.8 million false negatives. Over 15 years, the absolute difference between the most sensitive and most specific screening strategy was 4.5 million true positives and 476 million false-positives. Strategies using RPG cut points of 130 mg/dl or the multivariate equation every 3 years identified 17.3 million true positives; however, the equation identified fewer false-positives. The total cost of the most sensitive screening strategy was $42.7 billion and that of the most specific strategy was $6.9 billion. Screening for type 2 diabetes every 3 years with an RPG cut point of 130 mg/dl or the multivariate equation provides good yield and minimizes false-positive screening tests and costs.

  20. Breast cancer detection risk in screening mammography after a false-positive result.

    PubMed

    Castells, X; Román, M; Romero, A; Blanch, J; Zubizarreta, R; Ascunce, N; Salas, D; Burón, A; Sala, M

    2013-02-01

    False-positives are a major concern in breast cancer screening. However, false-positives have been little evaluated as a prognostic factor for cancer detection. Our aim was to evaluate the association of false-positive results with the cancer detection risk in subsequent screening participations over a 17-year period. This is a retrospective cohort study of 762,506 women aged 45-69 years, with at least two screening participations, who underwent 2,594,146 screening mammograms from 1990 to 2006. Multilevel discrete-time hazard models were used to estimate the adjusted odds ratios (OR) of breast cancer detection in subsequent screening participations in women with false-positive results. False-positives involving a fine-needle aspiration cytology or a biopsy had a higher cancer detection risk than those involving additional imaging procedures alone (OR = 2.69; 95%CI: 2.28-3.16 and OR = 1.81; 95%CI: 1.70-1.94, respectively). The risk of cancer detection increased substantially if women with cytology or biopsy had a familial history of breast cancer (OR = 4.64; 95%CI: 3.23-6.66). Other factors associated with an increased cancer detection risk were age 65-69 years (OR = 1.84; 95%CI: 1.67-2.03), non-attendance at the previous screening invitation (OR = 1.26; 95%CI: 1.11-1.43), and having undergone a previous benign biopsy outside the screening program (OR = 1.24; 95%CI: 1.13-1.35). Women with a false-positive test have an increased risk of cancer detection in subsequent screening participations, especially those with a false-positive result involving cytology or biopsy. Understanding the factors behind this association could provide valuable information to increase the effectiveness of breast cancer screening. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Psychological distress in U.S. women who have experienced false-positive mammograms.

    PubMed

    Jatoi, Ismail; Zhu, Kangmin; Shah, Mona; Lawrence, William

    2006-11-01

    In the United States, approximately 10.7% of all screening mammograms lead to a false-positive result, but the overall impact of false-positives on psychological well-being is poorly understood. Data were analyzed from the 2000 U.S. National Health Interview Survey (NHIS), the most recent national survey that included a cancer control module. Study subjects were 9,755 women who ever had a mammogram, of which 1,450 had experienced a false-positive result. Psychological distress was assessed using the validated K6 questionnaire and logistic regression was used to discern any association with previous false-positive mammograms. In a multivariate analysis, women who had indicated a previous false-positive mammogram were more likely to report feeling sad (OR = 1.18, 95% CI, 1.03-1.35), restless (OR = 1.23, 95% CI, 1.08-1.40), worthless (OR = 1.27, 95% CI, 1.04-1.54), and finding that everything was an effort (OR = 1.27, 95% CI, 1.10-1.47). These women were also more likely to have seen a mental health professional in the 12 months preceding the survey (OR = 1.28, 95% CI, 1.03-1.58) and had a higher composite score on all items of the K6 scale (P < 0.0001), a reflection of increased psychological distress. Analyses by age and race revealed that, among women who had experienced false-positives, younger women were more likely to feel that everything was an effort, and blacks were more likely to feel restless. In a random sampling of the U.S. population, women who had previously experienced false-positive mammograms were more likely to report symptoms of anxiety and depression.

  2. False-negative malaria rapid diagnostic tests in Rwanda: impact of Plasmodium falciparum isolates lacking hrp2 and declining malaria transmission.

    PubMed

    Kozycki, Christina T; Umulisa, Noella; Rulisa, Stephen; Mwikarago, Emil I; Musabyimana, Jean Pierre; Habimana, Jean Pierre; Karema, Corine; Krogstad, Donald J

    2017-03-20

    Rapid diagnostic tests (RDTs) for histidine rich protein 2 (HRP2) are often used to determine whether persons with fever should be treated with anti-malarials. However, Plasmodium falciparum parasites with a deletion of the hrp2 gene yield false-negative RDTs and there are concerns the sensitivity of HRP2-based RDTs may fall when the intensity of transmission decreases. This observational study enrolled 9226 patients at three health centres in Rwanda from April 2014 to April 2015. It then compared the sensitivity of RDTs based on HRP2 and the Plasmodium lactate dehydrogenase (pLDH) to microscopy (thick smears) for the diagnosis of malaria. PCR was used to determine whether deletions of the histidine-rich central repeat region of the hrp2 gene (exon 2) were associated with false-negative HRP2-based RDTs. In comparison to microscopy, the sensitivity and specificity of HRP2- and pLDH-based RDTs were 89.5 and 86.2% and 80.2 and 94.3%, respectively. When the results for both RDTs were combined, sensitivity rose to 91.8% and specificity was 85.7%. Additionally, when smear positivity fell from 46 to 3%, the sensitivity of the HRP2-based RDT fell from 88 to 67%. Of 370 samples with false-negative HRP2 RDT results for which PCR was performed, 140 (38%) were identified as P. falciparum by PCR. Of the isolates identified as P. falciparum by PCR, 32 (23%) were negative for the hrp2 gene based on PCR. Of the 32 P. falciparum isolates negative for hrp2 by PCR, 17 (53%) were positive based on the pLDH RDT. This prospective study of RDT performance coincided with a decline in the intensity of malaria transmission in Kibirizi (fall in slide positivity from 46 to 3%). This decline was associated with a decrease in HRP2 RDT sensitivity (from 88 to 67%). While P. falciparum isolates without the hrp2 gene were an important cause of false-negative HRP2-based RDTs, most were identified by the pLDH-based RDT. Although WHO does not recommend the use of combined HRP2/pLDH testing in sub-Saharan Africa, these results suggest that combination HRP2/pLDH-based RDTs could reduce the impact of false-negative HRP2-based RDTs for detection of symptomatic P. falciparum malaria.

  3. Performance characteristics of broth-only cultures after revision total joint arthroplasty.

    PubMed

    Smith, Eric B; Cai, Jenny; Wynne, Rachael; Maltenfort, Mitchell; Good, Robert P

    2014-11-01

    Surgeons frequently obtain intraoperative cultures at the time of revision total joint arthroplasty. The use of broth or liquid medium before applying the sample to the agar medium may be associated with contamination and false-positive cultures; however, the degree to which this is the case is not known. We (1) calculated the performance characteristics of broth-only cultures (sensitivity, specificity, positive predictive value, and negative predictive value) and (2) characterized the organisms identified in broth to determine whether a specific organism showed increased proclivity for true-positive periprosthetic joint infection (PJI). A single-institution retrospective chart review was performed on 257 revision total joint arthroplasties from 2009 through 2010. One hundred ninety (74%) had cultures for review. All culture results, as well as treatment, if any, were documented and patients were followed for a minimum of 1 year for evidence of PJI. Cultures were measured as either positive from the broth only or broth negative. The true diagnosis of infection was determined by the Musculoskeletal Infection Society criteria during the preoperative workup or postoperatively at 1 year for purposes of calculating the performance characteristics of the broth-only culture. The sensitivity, specificity, positive predictive value, and negative predictive value were 19%, 88%, 13%, and 92%, respectively. The most common organism identified was coagulase-negative Staphylococcus (16 of 24 cases, 67%). Coagulase-negative Staphylococcus was present in all three true-positive cases; however, it was also found in 13 of the false-positive cases. The broth-only positive cultures showed poor sensitivity and positive predictive value but good specificity and negative predictive value. The good specificity indicates that it can help to rule in the presence of PJI; however, the poor sensitivity makes broth-only culture an unreliable screening test. We recommend that broth-only culture results be carefully scrutinized and decisions on the diagnosis and treatment of infection should be based specifically on the Musculoskeletal Infection Society criteria. Level IV, diagnostic study. See Instructions for Authors for a complete description of levels of evidence.

  4. How to limit false positives in environmental DNA and metabarcoding?

    PubMed

    Ficetola, Gentile Francesco; Taberlet, Pierre; Coissac, Eric

    2016-05-01

    Environmental DNA (eDNA) and metabarcoding are boosting our ability to acquire data on species distribution in a variety of ecosystems. Nevertheless, as most of sampling approaches, eDNA is not perfect. It can fail to detect species that are actually present, and even false positives are possible: a species may be apparently detected in areas where it is actually absent. Controlling false positives remains a main challenge for eDNA analyses: in this issue of Molecular Ecology Resources, Lahoz-Monfort et al. () test the performance of multiple statistical modelling approaches to estimate the rate of detection and false positives from eDNA data. Here, we discuss the importance of controlling for false detection from early steps of eDNA analyses (laboratory, bioinformatics), to improve the quality of results and allow an efficient use of the site occupancy-detection modelling (SODM) framework for limiting false presences in eDNA analysis. © 2016 John Wiley & Sons Ltd.

  5. The Importance of Amoxicillin and Amoxicillin-Clavulanate Determinants in the Diagnosis of Immediate Allergic Reactions to β-Lactams.

    PubMed

    Confino-Cohen, Ronit; Rosman, Yossi; Lachover, Idit; Meir Shafrir, Keren; Goldberg, Arnon

    2016-01-01

    Immediate allergic reactions to β-lactam antibiotics are considered to be one of the most important drug hypersensitivities. A positive skin test (ST) with a combination of major and minor penicillin determinants is usually sufficient to recommend avoidance of the culprit drug, whereas a negative ST is usually followed by an oral challenge test (OCT). Recently, concern has been raised regarding the role of amoxicillin (AMX) ST in the diagnosis of AMX allergy. The aim of this study was to examine the additive value of AMX determinants in STs of patients with immediate hypersensitivity reactions to AMX or AMX-clavulanate (AMX-C). Patients with a history of immediate AMX or AMX-C allergy underwent an ST using a combination of penicilloyl-polylysine (PPL) and minor determinants as well as AMX. An ST with AMX-C was added when appropriate. Thirty-one patients were evaluated. Eight patients, all of them with a history of AMX allergy, had positive reactions only to the AMX component. Two patients with AMX-C allergy had a positive ST reaction only to the AMX-C component. Moreover, only 14 patients (13 with AMX and 1 with AMX-C allergy) had a positive reaction to PPL, whereas most patients (54.8%) had positive reactions to other determinants. One patient, who was positive for AMX, developed several urticarial lesions after the test. Skin testing with AMX and AMX-C is mandatory in patients with immediate allergy to these drugs. Failure to perform it may result in a false-negative ST jeopardizing these patients with anaphylactic reactions during a hazardous OCT. © 2016 S. Karger AG, Basel.

  6. Large Scale Mass Spectrometry-based Identifications of Enzyme-mediated Protein Methylation Are Subject to High False Discovery Rates*

    PubMed Central

    Hart-Smith, Gene; Yagoub, Daniel; Tay, Aidan P.; Pickford, Russell; Wilkins, Marc R.

    2016-01-01

    All large scale LC-MS/MS post-translational methylation site discovery experiments require methylpeptide spectrum matches (methyl-PSMs) to be identified at acceptably low false discovery rates (FDRs). To meet estimated methyl-PSM FDRs, methyl-PSM filtering criteria are often determined using the target-decoy approach. The efficacy of this methyl-PSM filtering approach has, however, yet to be thoroughly evaluated. Here, we conduct a systematic analysis of methyl-PSM FDRs across a range of sample preparation workflows (each differing in their exposure to the alcohols methanol and isopropyl alcohol) and mass spectrometric instrument platforms (each employing a different mode of MS/MS dissociation). Through 13CD3-methionine labeling (heavy-methyl SILAC) of Saccharomyces cerevisiae cells and in-depth manual data inspection, accurate lists of true positive methyl-PSMs were determined, allowing methyl-PSM FDRs to be compared with target-decoy approach-derived methyl-PSM FDR estimates. These results show that global FDR estimates produce extremely unreliable methyl-PSM filtering criteria; we demonstrate that this is an unavoidable consequence of the high number of amino acid combinations capable of producing peptide sequences that are isobaric to methylated peptides of a different sequence. Separate methyl-PSM FDR estimates were also found to be unreliable due to prevalent sources of false positive methyl-PSMs that produce high peptide identity score distributions. Incorrect methylation site localizations, peptides containing cysteinyl-S-β-propionamide, and methylated glutamic or aspartic acid residues can partially, but not wholly, account for these false positive methyl-PSMs. Together, these results indicate that the target-decoy approach is an unreliable means of estimating methyl-PSM FDRs and methyl-PSM filtering criteria. We suggest that orthogonal methylpeptide validation (e.g. heavy-methyl SILAC or its offshoots) should be considered a prerequisite for obtaining high confidence methyl-PSMs in large scale LC-MS/MS methylation site discovery experiments and make recommendations on how to reduce methyl-PSM FDRs in samples not amenable to heavy isotope labeling. Data are available via ProteomeXchange with the data identifier PXD002857. PMID:26699799

  7. Evaluation of MTANNs for eliminating false-positive with different computer aided pulmonary nodules detection software.

    PubMed

    Shi, Zhenghao; Ma, Jiejue; Feng, Yaning; He, Lifeng; Suzuki, Kenji

    2015-11-01

    MTANN (Massive Training Artificial Neural Network) is a promising tool, which applied to eliminate false-positive for thoracic CT in recent years. In order to evaluate whether this method is feasible to eliminate false-positive of different CAD schemes, especially, when it is applied to commercial CAD software, this paper evaluate the performance of the method for eliminating false-positives produced by three different versions of commercial CAD software for lung nodules detection in chest radiographs. Experimental results demonstrate that the approach is useful in reducing FPs for different computer aided lung nodules detection software in chest radiographs.

  8. Computerized mass detection in whole breast ultrasound images: reduction of false positives using bilateral subtraction technique

    NASA Astrophysics Data System (ADS)

    Ikedo, Yuji; Fukuoka, Daisuke; Hara, Takeshi; Fujita, Hiroshi; Takada, Etsuo; Endo, Tokiko; Morita, Takako

    2007-03-01

    The comparison of left and right mammograms is a common technique used by radiologists for the detection and diagnosis of masses. In mammography, computer-aided detection (CAD) schemes using bilateral subtraction technique have been reported. However, in breast ultrasonography, there are no reports on CAD schemes using comparison of left and right breasts. In this study, we propose a scheme of false positive reduction based on bilateral subtraction technique in whole breast ultrasound images. Mass candidate regions are detected by using the information of edge directions. Bilateral breast images are registered with reference to the nipple positions and skin lines. A false positive region is detected based on a comparison of the average gray values of a mass candidate region and a region with the same position and same size as the candidate region in the contralateral breast. In evaluating the effectiveness of the false positive reduction method, three normal and three abnormal bilateral pairs of whole breast images were employed. These abnormal breasts included six masses larger than 5 mm in diameter. The sensitivity was 83% (5/6) with 13.8 (165/12) false positives per breast before applying the proposed reduction method. By applying the method, false positives were reduced to 4.5 (54/12) per breast without removing a true positive region. This preliminary study indicates that the bilateral subtraction technique is effective for improving the performance of a CAD scheme in whole breast ultrasound images.

  9. Malingering in Toxic Exposure. Classification Accuracy of Reliable Digit Span and WAIS-III Digit Span Scaled Scores

    ERIC Educational Resources Information Center

    Greve, Kevin W.; Springer, Steven; Bianchini, Kevin J.; Black, F. William; Heinly, Matthew T.; Love, Jeffrey M.; Swift, Douglas A.; Ciota, Megan A.

    2007-01-01

    This study examined the sensitivity and false-positive error rate of reliable digit span (RDS) and the WAIS-III Digit Span (DS) scaled score in persons alleging toxic exposure and determined whether error rates differed from published rates in traumatic brain injury (TBI) and chronic pain (CP). Data were obtained from the files of 123 persons…

  10. Facing the problem of "false positives": re-assessment and improvement of a multiplex RT-PCR procedure for the diagnosis of A. flavus mycotoxin producers.

    PubMed

    Degola, F; Berni, E; Spotti, E; Ferrero, I; Restivo, F M

    2009-02-28

    The aim of our research project was to consolidate a multiplex RT-PCR protocol to detect aflatoxigenic strains of Aspergillus flavus. Several independent A. flavus strains were isolated from corn and flour samples from the North of Italy and from three European countries. Aflatoxin producing/not producing phenotype was assessed by qualitative and quantitative assays at day five of growth in aflatoxin inducing conditions. Expression of 16 genes belonging to the aflatoxin cluster was assayed by multiplex or monomeric RT-PCR. There is a good correlation between gene expression and aflatoxin production. Strains that apparently transcribed all the relevant genes but did not release aflatoxin in the medium ("false positives") were re-assessed for mycotoxin production after extended growth in inducing condition. All the "false positive" strains in actual fact were positive when aflatoxin determination was performed after 10 days of growth. These strains should then be re-classified as "slow aflatoxin accumulators". To optimise the diagnostic procedure, a quintuplex RT-PCR procedure was designed consisting of a primer set directed against four informative aflatoxin cluster genes and the beta-tubulin gene as an internal amplification control. In conclusion we have provided evidence for the robustness and reliability of our RT-PCR protocol in discriminating mycotoxin producer from non-producer strains of A. flavus. and the molecular procedure we devised is a promising tool with which to screen and control the endemic population of A. flavus colonising different areas of the World.

  11. Evaluation of fecal elastase and serum cholecystokinin in dogs with a false positive fecal elastase test.

    PubMed

    Steiner, J M; Rehfeld, J F; Pantchev, N

    2010-01-01

    An assay for the measurement of pancreatic elastase in dog feces has been introduced. The goal of this study was to evaluate the rate of false-positive fecal-elastase test results in dogs with suspected exocrine pancreatic insufficiency (EPI) and to assess serum cholecystokinin (CCK) concentrations in dogs with a false positive fecal elastase test result. Twenty-six fecal and serum samples from dogs suspected of EPI, for which samples had been submitted to a commercial laboratory (Vet Med Labor) for analysis. Prospective study. Serum trypsin-like immunoreactivity (TLI) was measured in 26 dogs with a decreased fecal elastase concentration of <10 microg/g feces. Serum CCK concentrations were measured in 21 of these dogs. Of 26 dogs with a decreased fecal elastase concentration, 6 (23%) had serum TLI concentrations within or above the reference range. Serum CCK concentrations were significantly higher in dogs with a true positive fecal elastase test result (median: 1.1 pmol/L; range: 0.1-3.3 pmol/L) than in those with a false positive fecal elastase test result (median: 0.1 pmol/L; range: 0.1-0.9 pmol/L; P value = .0163). The rate of false positive fecal elastase test results was high in this group of dogs, suggesting that diagnosis of EPI must be confirmed by other means. The decreased CCK concentration in dogs with a false positive fecal elastase test result could suggest that false positive results are because of decreased stimulation of exocrine pancreatic function caused by other conditions.

  12. Ordering blood tests for patients with unexplained fatigue in general practice: what does it yield? Results of the VAMPIRE trial.

    PubMed

    Koch, Hèlen; van Bokhoven, Marloes A; ter Riet, Gerben; van Alphen-Jager, Jm Tineke; van der Weijden, Trudy; Dinant, Geert-Jan; Bindels, Patrick J E

    2009-04-01

    Unexplained fatigue is frequently encountered in general practice. Because of the low prior probability of underlying somatic pathology, the positive predictive value of abnormal (blood) test results is limited in such patients. The study objectives were to investigate the relationship between established diagnoses and the occurrence of abnormal blood test results among patients with unexplained fatigue; to survey the effects of the postponement of test ordering on this relationship; and to explore consultation-related determinants of abnormal test results. Cluster randomised trial. General practices of 91 GPs in the Netherlands. GPs were randomised to immediate or postponed blood-test ordering. Patients with new unexplained fatigue were included. Limited and expanded sets of blood tests were ordered either immediately or after 4 weeks. Diagnoses during the 1-year follow-up period were extracted from medical records. Two-by-two tables were generated. To establish independent determinants of abnormal test results, a multivariate logistic regression model was used. Data of 325 patients were analysed (71% women; mean age 41 years). Eight per cent of patients had a somatic illness that was detectable by blood-test ordering. The number of false-positive test results increased in particular in the expanded test set. Patients rarely re-consulted after 4 weeks. Test postponement did not affect the distribution of patients over the two-by-two tables. No independent consultation-related determinants of abnormal test results were found. Results support restricting the number of tests ordered because of the increased risk of false-positive test results from expanded test sets. Although the number of re-consulting patients was small, the data do not refute the advice to postpone blood-test ordering for medical reasons in patients with unexplained fatigue in general practice.

  13. Dental pulp neurophysiology: part 2. Current diagnostic tests to assess pulp vitality.

    PubMed

    Abd-Elmeguid, Ashraf; Yu, Donald C

    2009-03-01

    In this second part of our 2-part review, we discuss recent research about pulp tests that determine the vitality of the tooth and clinically accepted pulp testers. A pain response to hot, cold or an electric pulp tester indicates the vitality of only a tooth's pulpal sensory supply; the response does not give any idea about the state of the pulp. Although the sensitivity of these tests is high, when false-positive and false-negative results occur, they may affect the treatment of the tooth. A tooth falsely diagnosed as nonvital with an electric pulp tester may undergo an unnecessary root canal, whereas one falsely diagnosed as vital may be left untreated, causing the necrotic tissue to destroy the supporting tissues (resorption). The vascular supply is more important to the determination of the health of the pulp than the sensory supply. Pulp death is caused by cessation of blood flow and may result in a necrotic pulp, even though the pulpal sensory supply may still be viable. The pulp can be healed only if the circulating blood flow is healthy. Although still under investigation, diagnostic devices that examine pulpal blood flow, such as the pulse oximeter and laser Doppler flowmetry, show promising results for the assessment of pulp vitality.

  14. Sherlock Holmes and child psychopathology assessment approaches: the case of the false-positive.

    PubMed

    Jensen, P S; Watanabe, H

    1999-02-01

    To explore the relative value of various methods of assessing childhood psychopathology, the authors compared 4 groups of children: those who met criteria for one or more DSM diagnoses and scored high on parent symptom checklists, those who met psychopathology criteria on either one of these two assessment approaches alone, and those who met no psychopathology assessment criterion. Parents of 201 children completed the Child Behavior Checklist (CBCL), after which children and parents were administered the Diagnostic Interview Schedule for Children (version 2.1). Children and parents also completed other survey measures and symptom report inventories. The 4 groups of children were compared against "external validators" to examine the merits of "false-positive" and "false-negative" cases. True-positive cases (those that met DSM criteria and scored high on the CBCL) differed significantly from the true-negative cases on most external validators. "False-positive" and "false-negative" cases had intermediate levels of most risk factors and external validators. "False-positive" cases were not normal per se because they scored significantly above the true-negative group on a number of risk factors and external validators. A similar but less marked pattern was noted for "false-negatives." Findings call into question whether cases with high symptom checklist scores despite no formal diagnoses should be considered "false-positive." Pending the availability of robust markers for mental illness, researchers and clinicians must resist the tendency to reify diagnostic categories or to engage in arcane debates about the superiority of one assessment approach over another.

  15. Optical detection of chemical warfare agents and toxic industrial chemicals

    NASA Astrophysics Data System (ADS)

    Webber, Michael E.; Pushkarsky, Michael B.; Patel, C. Kumar N.

    2004-12-01

    We present an analytical model evaluating the suitability of optical absorption based spectroscopic techniques for detection of chemical warfare agents (CWAs) and toxic industrial chemicals (TICs) in ambient air. The sensor performance is modeled by simulating absorption spectra of a sample containing both the target and multitude of interfering species as well as an appropriate stochastic noise and determining the target concentrations from the simulated spectra via a least square fit (LSF) algorithm. The distribution of the LSF target concentrations determines the sensor sensitivity, probability of false positives (PFP) and probability of false negatives (PFN). The model was applied to CO2 laser based photoacosutic (L-PAS) CWA sensor and predicted single digit ppb sensitivity with very low PFP rates in the presence of significant amount of interferences. This approach will be useful for assessing sensor performance by developers and users alike; it also provides methodology for inter-comparison of different sensing technologies.

  16. Detection of CIN by naked eye visualization after application of acetic acid.

    PubMed

    Londhe, M; George, S S; Seshadri, L

    1997-06-01

    A prospective study was undertaken to determine the sensitivity and specificity of acetic application to the cervix followed by naked eye visualization as a screening test for detection of cervical intraepithelial neoplasia. Three hundred and seventy two sexually active woman in the reproductive age group were studied. All the women underwent Papanicolaou test, acetic acid test and colposcopy. One hundred and seventy five woman were acetic acid test negative, 197 women were acetic acid test positive. The sensitivity of acetic acid test was 72.4%, specificity 54% and false negative rate 15.2%, as compared to papanicolaou test which had a sensitivity of 13.2%, specificity of 96.3% and false negative rate of 24.4%. The advantage of the acetic acid test lies in its easy technique, low cost and high sensitivity which are important factors for determining the efficacy of any screening programme in developing countries.

  17. DuPont qualicon BAX system real-time PCR assay for Escherichia coli O157:H7.

    PubMed

    Burns, Frank; Fleck, Lois; Andaloro, Bridget; Davis, Eugene; Rohrbeck, Jeff; Tice, George; Wallace, Morgan

    2011-01-01

    Evaluations were conducted to test the performance of the BAX System Real-Time PCR assay, which was certified as Performance Tested Method 031002 for screening E. coli O157:H7 in ground beef, beef trim, spinach, and lettuce. Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent or superior to the FDA-BAM and the USDA-FSIS culture methods, but with a significantly shorter time to result. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined affect the performance of the assay. An accelerated shelf life study determined an initial 36 month shelf life for the test kit.

  18. Performance of the G4 Xpert® MTB/RIF assay for the detection of Mycobacterium tuberculosis and rifampin resistance: a retrospective case-control study of analytical and clinical samples from high- and low-tuberculosis prevalence settings.

    PubMed

    Dharan, Nila J; Blakemore, Robert; Sloutsky, Alex; Kaur, Devinder; Alexander, Richard C; Ghajar, Minoo; Musser, Kimberlee A; Escuyer, Vincent E; Rowlinson, Marie-Claire; Crowe, Susanne; Laniado-Laborin, Rafael; Valli, Eloise; Nabeta, Pamela; Johnson, Pamela; Alland, David

    2016-12-20

    The Xpert ® MTB/RIF (Xpert) assay is a rapid PCR-based assay for the detection of Mycobacterium tuberculosis complex DNA (MTBc) and mutations associated with rifampin resistance (RIF). An updated version introduced in 2011, the G4 Xpert, included modifications to probe B and updated analytic software. An analytical study was performed to assess Xpert detection of mutations associated with rifampin resistance in rifampin-susceptible and -resistant isolates. A clinical study was performed in which specimens from US and non-US persons suspected of tuberculosis (TB) were tested to determine Xpert performance characteristics. All specimens underwent smear microscopy, mycobacterial culture, conventional drug-susceptibility testing and Xpert testing; DNA from isolates with discordant rifampin resistance results was sequenced. Among 191 laboratory-prepared isolates in the analytical study, Xpert sensitivity for detection of rifampin resistance associated mutations was 97.7% and specificity was 90.8%, which increased to 99.0% after DNA sequencing analysis of the discordant samples. Of the 1,096 subjects in the four clinical studies, 49% were from the US. Overall, Xpert detected MTBc in 439 of 468 culture-positive specimens for a sensitivity of 93.8% (95% confidence interval [CI]: 91.2%-95.7%) and did not detect MTBc in 620 of 628 culture-negative specimens for a specificity of 98.7% (95% CI: 97.5%-99.4%). Sensitivity was 99.7% among smear-positive cases, and 76.1% among smear-negative cases. Non-determinate MTBc detection and false-positive RIF resistance results were low (1.2 and 0.9%, respectively). The updated Xpert assay retained the high sensitivity and specificity of the previous assay versions and demonstrated low rates of non-determinate and RIF resistance false positive results.

  19. Variation in false-positive rates of mammography reading among 1067 radiologists: a population-based assessment.

    PubMed

    Tan, Alai; Freeman, Daniel H; Goodwin, James S; Freeman, Jean L

    2006-12-01

    The accuracy of mammography reading varies among radiologists. We conducted a population-based assessment on radiologist variation in false- positive rates of screening mammography and its associated radiologist characteristics. About 27,394 screening mammograms interpreted by 1067 radiologists were identified from a 5% non-cancer sample of Medicare claims during 1998-1999. The data were linked to the American Medical Association Masterfile to obtain radiologist characteristics. Multilevel logistic regression models were used to examine the radiologist variation in false-positive rates of screening mammography and the associated radiologist characteristics. Radiologists varied substantially in the false-positive rates of screening mammography (ranging from 1.5 to 24.1%, adjusting for patient characteristics). A longer time period since graduation is associated with lower false-positive rates (odds ratio [OR] for every 10 years increase: 0.87, 95% Confidence Interval [CI], 0.81-0.94) and female radiologists had higher false-positive rates than male radiologists (OR = 1.25, 95% CI, 1.05-1.49), adjusting for patient and other radiologist characteristics. The unmeasured factors contributed to about 90% of the between-radiologist variance. Radiologists varied greatly in accuracy of mammography reading. Female and more recently trained radiologists had higher false-positive rates. The variation among radiologists was largely due to unmeasured factors, especially unmeasured radiologist factors. If our results are confirmed in further studies, they suggest that system-level interventions would be required to reduce variation in mammography interpretation.

  20. Is it time to sound an alarm about false-positive cell-free DNA testing for fetal aneuploidy?

    PubMed

    Mennuti, Michael T; Cherry, Athena M; Morrissette, Jennifer J D; Dugoff, Lorraine

    2013-11-01

    Testing cell-free DNA (cfDNA) in maternal blood samples has been shown to have very high sensitivity for the detection of fetal aneuploidy with very low false-positive results in high-risk patients who undergo invasive prenatal diagnosis. Recent observation in clinical practice of several cases of positive cfDNA tests for trisomy 18 and trisomy 13, which were not confirmed by cytogenetic testing of the pregnancy, may reflect a limitation of the positive predictive value of this quantitative testing, particularly when it is used to detect rare aneuploidies. Analysis of a larger number of false-positive cases is needed to evaluate whether these observations reflect the positive predictive value that should be expected. Infrequently, mechanisms (such as low percentage mosaicism or confined placental mosaicism) might also lead to positive cfDNA testing that is not concordant with standard prenatal cytogenetic diagnosis. The need to explore these and other possible causes of false-positive cfDNA testing is exemplified by 2 of these cases. Additional evaluation of cfDNA testing in clinical practice and a mechanism for the systematic reporting of false-positive and false-negative cases will be important before this test is offered widely to the general population of low-risk obstetric patients. In the meantime, incorporating information about the positive predictive value in pretest counseling and in clinical laboratory reports is recommended. These experiences reinforce the importance of offering invasive testing to confirm cfDNA results before parental decision-making. Copyright © 2013 Mosby, Inc. All rights reserved.

  1. False-positive findings in Cochrane meta-analyses with and without application of trial sequential analysis: an empirical review.

    PubMed

    Imberger, Georgina; Thorlund, Kristian; Gluud, Christian; Wetterslev, Jørn

    2016-08-12

    Many published meta-analyses are underpowered. We explored the role of trial sequential analysis (TSA) in assessing the reliability of conclusions in underpowered meta-analyses. We screened The Cochrane Database of Systematic Reviews and selected 100 meta-analyses with a binary outcome, a negative result and sufficient power. We defined a negative result as one where the 95% CI for the effect included 1.00, a positive result as one where the 95% CI did not include 1.00, and sufficient power as the required information size for 80% power, 5% type 1 error, relative risk reduction of 10% or number needed to treat of 100, and control event proportion and heterogeneity taken from the included studies. We re-conducted the meta-analyses, using conventional cumulative techniques, to measure how many false positives would have occurred if these meta-analyses had been updated after each new trial. For each false positive, we performed TSA, using three different approaches. We screened 4736 systematic reviews to find 100 meta-analyses that fulfilled our inclusion criteria. Using conventional cumulative meta-analysis, false positives were present in seven of the meta-analyses (7%, 95% CI 3% to 14%), occurring more than once in three. The total number of false positives was 14 and TSA prevented 13 of these (93%, 95% CI 68% to 98%). In a post hoc analysis, we found that Cochrane meta-analyses that are negative are 1.67 times more likely to be updated (95% CI 0.92 to 2.68) than those that are positive. We found false positives in 7% (95% CI 3% to 14%) of the included meta-analyses. Owing to limitations of external validity and to the decreased likelihood of updating positive meta-analyses, the true proportion of false positives in meta-analysis is probably higher. TSA prevented 93% of the false positives (95% CI 68% to 98%). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. Evaluation of positive and false-positive results in syphilis screening of blood donors in Rio de Janeiro, Brazil.

    PubMed

    Sandes, V S; Silva, S G C; Motta, I J F; Velarde, L G C; de Castilho, S R

    2017-06-01

    We propose to analyse the positive and false-positive results of treponemal and nontreponemal tests in blood donors from Brazil and to evaluate possible factors associated with the results of treponemal tests. Treponemal tests have been used widely for syphilis screening in blood banks. The introduction of these tests in donor screening has caused an impact and a loss of donors who need to be assessed. This was a retrospective cross-sectional study of syphilis screening and confirmatory test results of blood donors that were obtained before and after adopting a chemiluminescent immunoassay (CLIA). A comparative analysis was performed using a second sample drawn from positive donors. The possible factors associated with CLIA-positive or CLIA-false-positive results were investigated in a subgroup. Statistical tests were used to compare the proportions and adjusted estimates of association. The reactivity rate increased from 1·01% (N = 28 158) to 2·66% (N = 25 577) after introducing the new test. Among Venereal Disease Research Laboratory (VDRL)- and CLIA-confirmed results, the false-positive rates were 40·5% (N = 180) and 37·4% (N = 359), respectively (P = 0·5266). Older donors (OR = 1·04; P = 0·0010) and donors with lower education levels (OR = 6·59; P = 0·0029) were associated with a higher risk of positivity for syphilis. CLIA represents an improvement in blood bank serological screening. However, its use in a healthy population appears to result in high rates of false positives. Identifying which characteristics can predict false positives, however, remains a challenge. © 2017 British Blood Transfusion Society.

  3. Comparison of 3 Methods to Assess Urine Specific Gravity in Collegiate Wrestlers.

    PubMed

    Stuempfle, Kristin J.; Drury, Daniel G.

    2003-12-01

    OBJECTIVE: To investigate the reliability and validity of refractometry, hydrometry, and reagent strips in assessing urine specific gravity in collegiate wrestlers. DESIGN AND SETTING: We assessed the reliability of refractometry, hydrometry, and reagent strips between 2 trials and among 4 testers. The validity of hydrometry and reagent strips was assessed by comparison with refractometry, the criterion measure for urine specific gravity. SUBJECTS: Twenty-one National Collegiate Athletic Association Division III collegiate wrestlers provided fresh urine samples. MEASUREMENTS: Four testers measured the specific gravity of each urine sample 6 times: twice by refractometry, twice by hydrometry, and twice by reagent strips. RESULTS: Refractometer measurements were consistent between trials (R =.998) and among testers; hydrometer measurements were consistent between trials (R =.987) but not among testers; and reagent-strip measurements were not consistent between trials or among testers. Hydrometer (1.018 +/- 0.006) and reagent-strip (1.017 +/- 0.007) measurements were significantly higher than refractometer (1.015 +/- 0.006) measurements. Intraclass correlation coefficients were moderate between refractometry and hydrometry (R =.869) and low between refractometry and reagent strips (R =.573). The hydrometer produced 28% false positives and 2% false negatives, and reagent strips produced 15% false positives and 9% false negatives. CONCLUSIONS: Only the refractometer should be used to determine urine specific gravity in collegiate wrestlers during the weight-certification process.

  4. Comparison of 3 Methods to Assess Urine Specific Gravity in Collegiate Wrestlers

    PubMed Central

    Drury, Daniel G.

    2003-01-01

    Objective: To investigate the reliability and validity of refractometry, hydrometry, and reagent strips in assessing urine specific gravity in collegiate wrestlers. Design and Setting: We assessed the reliability of refractometry, hydrometry, and reagent strips between 2 trials and among 4 testers. The validity of hydrometry and reagent strips was assessed by comparison with refractometry, the criterion measure for urine specific gravity. Subjects: Twenty-one National Collegiate Athletic Association Division III collegiate wrestlers provided fresh urine samples. Measurements: Four testers measured the specific gravity of each urine sample 6 times: twice by refractometry, twice by hydrometry, and twice by reagent strips. Results: Refractometer measurements were consistent between trials (R = .998) and among testers; hydrometer measurements were consistent between trials (R = .987) but not among testers; and reagent-strip measurements were not consistent between trials or among testers. Hydrometer (1.018 ± 0.006) and reagent-strip (1.017 ± 0.007) measurements were significantly higher than refractometer (1.015 ± 0.006) measurements. Intraclass correlation coefficients were moderate between refractometry and hydrometry (R = .869) and low between refractometry and reagent strips (R = .573). The hydrometer produced 28% false positives and 2% false negatives, and reagent strips produced 15% false positives and 9% false negatives. Conclusions: Only the refractometer should be used to determine urine specific gravity in collegiate wrestlers during the weight-certification process. PMID:14737213

  5. Evaluation of the light scattering and the turbidity microtiter plate-based methods for the detection of the excipient-mediated drug precipitation inhibition.

    PubMed

    Petruševska, Marija; Urleb, Uroš; Peternel, Luka

    2013-11-01

    The excipient-mediated precipitation inhibition is classically determined by the quantification of the dissolved compound in the solution. In this study, two alternative approaches were evaluated, one is the light scattering (nephelometer) and other is the turbidity (plate reader) microtiter plate-based methods which are based on the quantification of the compound precipitate. Following the optimization of the nephelometer settings (beam focus, laser gain) and the experimental conditions, the screening of 23 excipients on the precipitation inhibition of poorly soluble fenofibrate and dipyridamole was performed. The light scattering method resulted in excellent correlation (r>0.91) between the calculated precipitation inhibitor parameters (PIPs) and the precipitation inhibition index (PI(classical)) obtained by the classical approach for fenofibrate and dipyridamole. Among the evaluated PIPs AUC100 (nephelometer) resulted in only four false positives and lack of false negatives. In the case of the turbidity-based method a good correlation of the PI(classical) was obtained for the PIP maximal optical density (OD(max), r=0.91), however, only for fenofibrate. In the case of the OD(max) (plate reader) five false positives and two false negatives were identified. In conclusion, the light scattering-based method outperformed the turbidity-based one and could be reliably used for identification of novel precipitation inhibitors. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. How pH, Temperature, and Time of Incubation Affect False-Positive Responses and Uncertainty of the LAL Gel-Clot Test.

    PubMed

    Lourenço, Felipe Rebello; Botelho, Túlia De Souza; Pinto, Terezinha De Jesus Andreoli

    2012-01-01

    The limulus amebocyte lysate (LAL) test is the simplest and most widely used procedure for detection of endotoxin in parenteral drugs. The LAL test demands optimal pH, ionic strength, temperature, and time of incubation. Slight changes in these parameters may increase the frequency of false-positive responses and the estimated uncertainty of the LAL test. The aim of this paper is to evaluate how changes in the pH, temperature, and time of incubation affect the occurrence of false-positive responses in the LAL test. LAL tests were performed in nominal conditions (37 °C, 60 min, and pH 7) and in different conditions of temperature (36 °C and 38 °C), time of incubation (58 and 62 min), and pH (6 and 8). Slight differences in pH increase the frequency of false-positive responses 5-fold (relative risk 5.0), resulting in an estimated of uncertainty 7.6%. Temperature and time of incubation affect the LAL test less, showing relative risks of 1.5 and 1.0, respectively. Estimated uncertainties in 36 °C or 38 °C temperatures and 58 or 62 min of incubation were found to be 2.0% and 1.0%, respectively. Simultaneous differences in these parameters significantly increase the frequency of false-positive responses. The limulus amebocyte lysate (LAL) gel-clot test is a simple test for detection of endotoxin from Gram-negative bacteria. The test is based on a gel formation when a certain amount of endotoxin is present; it is a pass/fail test. The LAL test requires optimal pH, ionic strength, temperature, and time of incubation. Slight difference in these parameters may increase the frequency of false-positive responses. The aim of this paper is to evaluate how changes in the pH, temperature, and time of incubation affect the occurrence of false-positive responses in the LAL test. We find that slight differences in pH increase the frequency of false-positive responses 5-fold. Temperature and time of incubation affect the LAL test less. Simultaneous differences in these parameters significantly increase the frequency of false-positive responses.

  7. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mordang, Jan-Jurre, E-mail: Jan-Jurre.Mordang@radboudumc.nl; Gubern-Mérida, Albert; Karssemeijer, Nico

    Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performancemore » of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8–1.0 were significantly different between the system without BACs removal and the system with BACs removal, 0.129 ± 0.009 versus 0.144 ± 0.008 (p<0.05), respectively. Additionally, the sensitivity at one false positive per 50 cases and one false positive per 25 cases increased as well, 37% versus 51% (p<0.05) and 58% versus 67% (p<0.05) sensitivity, respectively. Additionally, the CADe system with BACs removal reduces the number of false positives per case by 29% on average. The same sensitivity at one false positive per 50 cases in the CADe system without BACs removal can be achieved at one false positive per 80 cases in the CADe system with BACs removal. Conclusions: By using dedicated algorithms to detect and remove breast arterial calcifications, the performance of CADe systems can be improved, in particular, at false positive rates representative for operating points used in screening.« less

  8. Screening for erectile dysfunction in men with lifelong premature ejaculation--Is the Sexual Health Inventory for Men (SHIM) reliable?

    PubMed

    McMahon, Chris G

    2009-02-01

    Some men with premature ejaculation (PE) and normal erectile function record contradictory response/s to The Sexual Health Inventory for Men (SHIM) and may be incorrectly categorized as suffering from erectile dysfunction (ED). The aim of this study was to evaluate the frequency of false positive SHIM diagnosis of ED in men with lifelong PE. SHIM, stopwatch intravaginal ejaculation latency time (IELT). A prospective observational study of men with normal erectile function and lifelong PE, diagnosed using the ISSM definition of lifelong PE, was conducted. The SHIM was self-administered at Visit 1. Mean per subject stopwatch IELT was determined from four subsequent intercourse attempts. Seventy-eight subjects with a mean age of 33.2 +/- 8.3 years and a geometric mean IELT of 15.9 +/- 2.3 seconds were enrolled. The mean SHIM score for all subjects was 20.4 +/- 6.0. Fifty-two subjects (66.7%) have SHIM scores of >21 (mean 24.3 +/- 1.1), consistent with normal erectile function, and a geometric mean IELT of 18.3 +/- 2.2 seconds. Twenty-six subjects (33.3%) had SHIM scores <22 (mean 12.7 +/- 3.7), consistent with a false positive diagnosis of ED, and a geometric mean IELT of 10.5 +/- 2.3 seconds. The incidence of false positive SHIM diagnosis of ED (SHIM < 22) was inversely related to the IELT. Although the geometric mean IELT for subjects with SHIM scores <22 was significantly less than that of all subjects and subjects with SHIM scores >21, there were no significant differences between the geometric mean IELT or the IELT distribution of all subjects vs. the normal erectile function IELT (SHIM > 21) cohort. This study demonstrates a 33.3% false positive SHIM diagnosis of ED in men with PE. This is likely to limit subject recruitment in clinical trials by exclusion of subjects with low-range IELTs but is unlikely to result in significantly different baseline IELTs or IELT distributions.

  9. Bone marrow cells stained by azide-conjugated Alexa fluors in the absence of an alkyne label.

    PubMed

    Lin, Guiting; Ning, Hongxiu; Banie, Lia; Qiu, Xuefeng; Zhang, Haiyang; Lue, Tom F; Lin, Ching-Shwun

    2012-09-01

    Thymidine analog 5-ethynyl-2'-deoxyuridine (EdU) has recently been introduced as an alternative to 5-bromo-2-deoxyuridine (BrdU) for cell labeling and tracking. Incorporation of EdU into replicating DNA can be detected by azide-conjugated fluors (eg, Alexa-azide) through a Cu(i)-catalyzed click reaction between EdU's alkyne moiety and azide. While this cell labeling method has proven to be valuable for tracking transplanted stem cells in various tissues, we have found that some bone marrow cells could be stained by Alexa-azide in the absence of EdU label. In intact rat femoral bone marrow, ~3% of nucleated cells were false-positively stained, and in isolated bone marrow cells, ~13%. In contrast to true-positive stains, which localize in the nucleus, the false-positive stains were cytoplasmic. Furthermore, while true-positive staining requires Cu(i), false-positive staining does not. Reducing the click reaction time or reducing the Alexa-azide concentration failed to improve the distinction between true- and false-positive staining. Hematopoietic and mesenchymal stem cell markers CD34 and Stro-1 did not co-localize with the false-positively stained cells, and these cells' identity remains unknown.

  10. The diagnostic performance evaluation of the SD BIOLINE HIV/syphilis Duo rapid test in southern Ethiopia: a cross-sectional study

    PubMed Central

    Shimelis, Techalew; Tadesse, Endale

    2015-01-01

    Objective To determine the diagnostic performance of the SD BIOLINE HIV/syphilis Duo rapid test. Design A hospital-based cross-sectional study. Setting This evaluation was conducted at one of the largest hospitals in southern Ethiopia. Participants Serum samples obtained from clients attending the antiretroviral therapy and voluntary counselling and testing centres were used. Sera were originally collected for the purpose of investigating syphilis epidemiology. The performance of the test to detect HIV was evaluated using 400 sera (200 HIV positives and 200 HIV negatives). Also, its performance to detect syphilis was evaluated using 85 syphilis positive and 100 syphilis negative serum samples. Individuals <15 years of age or syphilis treated or those with ≤50 cells/µL CD4 cell count were originally excluded. Outcome measures HIV screening was carried out according to the national rapid diagnostic testing (RDT) algorithm: Shenghai Kehua Bioengineering (KHB) test kit as a screening test, followed by the HIV1/2 STAT-PAK assay if positive. Where the result of the STAT-PAK is discordant with KHB, Unigold HIV is used as a tiebreaker to determine the result. We also used ELISA to resolve discordant HIV results. Syphilis serostatus was determined using the Treponema pallidum haemagglutination assay (TPHA). Results The respective sensitivity, specificity, positive predictive value and negative predictive value of the SD BIOLINE HIV/syphilis Duo test were 100, 99.5, 99.5 and 100% for HIV and 97.6, 96, 95.4 and 98% for syphilis testing, respectively. In reference to TPHA, the test kit reported 4 false positives and 2 false negative results for syphilis. The κ values were 0.99 for HIV testing and 0.94 for syphilis testing. Conclusions The excellent performance of the SD BIOLINE HIV/syphilis Duo test to detect HIV as well as syphilis facilitates the integration of syphilis testing and treatment to the already established HIV prevention programme, ultimately contributing to the dual HIV and syphilis elimination goal. PMID:25908677

  11. The diagnostic performance evaluation of the SD BIOLINE HIV/syphilis Duo rapid test in southern Ethiopia: a cross-sectional study.

    PubMed

    Shimelis, Techalew; Tadesse, Endale

    2015-04-23

    To determine the diagnostic performance of the SD BIOLINE HIV/syphilis Duo rapid test. A hospital-based cross-sectional study. This evaluation was conducted at one of the largest hospitals in southern Ethiopia. Serum samples obtained from clients attending the antiretroviral therapy and voluntary counselling and testing centres were used. Sera were originally collected for the purpose of investigating syphilis epidemiology. The performance of the test to detect HIV was evaluated using 400 sera (200 HIV positives and 200 HIV negatives). Also, its performance to detect syphilis was evaluated using 85 syphilis positive and 100 syphilis negative serum samples. Individuals <15 years of age or syphilis treated or those with ≤50 cells/µL CD4 cell count were originally excluded. HIV screening was carried out according to the national rapid diagnostic testing (RDT) algorithm: Shenghai Kehua Bioengineering (KHB) test kit as a screening test, followed by the HIV1/2 STAT-PAK assay if positive. Where the result of the STAT-PAK is discordant with KHB, Unigold HIV is used as a tiebreaker to determine the result. We also used ELISA to resolve discordant HIV results. Syphilis serostatus was determined using the Treponema pallidum haemagglutination assay (TPHA). The respective sensitivity, specificity, positive predictive value and negative predictive value of the SD BIOLINE HIV/syphilis Duo test were 100, 99.5, 99.5 and 100% for HIV and 97.6, 96, 95.4 and 98% for syphilis testing, respectively. In reference to TPHA, the test kit reported 4 false positives and 2 false negative results for syphilis. The κ values were 0.99 for HIV testing and 0.94 for syphilis testing. The excellent performance of the SD BIOLINE HIV/syphilis Duo test to detect HIV as well as syphilis facilitates the integration of syphilis testing and treatment to the already established HIV prevention programme, ultimately contributing to the dual HIV and syphilis elimination goal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Highly sensitive detection of individual HEAT and ARM repeats with HHpred and COACH.

    PubMed

    Kippert, Fred; Gerloff, Dietlind L

    2009-09-24

    HEAT and ARM repeats occur in a large number of eukaryotic proteins. As these repeats are often highly diverged, the prediction of HEAT or ARM domains can be challenging. Except for the most clear-cut cases, identification at the individual repeat level is indispensable, in particular for determining domain boundaries. However, methods using single sequence queries do not have the sensitivity required to deal with more divergent repeats and, when applied to proteins with known structures, in some cases failed to detect a single repeat. Testing algorithms which use multiple sequence alignments as queries, we found two of them, HHpred and COACH, to detect HEAT and ARM repeats with greatly enhanced sensitivity. Calibration against experimentally determined structures suggests the use of three score classes with increasing confidence in the prediction, and prediction thresholds for each method. When we applied a new protocol using both HHpred and COACH to these structures, it detected 82% of HEAT repeats and 90% of ARM repeats, with the minimum for a given protein of 57% for HEAT repeats and 60% for ARM repeats. Application to bona fide HEAT and ARM proteins or domains indicated that similar numbers can be expected for the full complement of HEAT/ARM proteins. A systematic screen of the Protein Data Bank for false positive hits revealed their number to be low, in particular for ARM repeats. Double false positive hits for a given protein were rare for HEAT and not at all observed for ARM repeats. In combination with fold prediction and consistency checking (multiple sequence alignments, secondary structure prediction, and position analysis), repeat prediction with the new HHpred/COACH protocol dramatically improves prediction in the twilight zone of fold prediction methods, as well as the delineation of HEAT/ARM domain boundaries. A protocol is presented for the identification of individual HEAT or ARM repeats which is straightforward to implement. It provides high sensitivity at a low false positive rate and will therefore greatly enhance the accuracy of predictions of HEAT and ARM domains.

  13. Highly Sensitive Detection of Individual HEAT and ARM Repeats with HHpred and COACH

    PubMed Central

    Kippert, Fred; Gerloff, Dietlind L.

    2009-01-01

    Background HEAT and ARM repeats occur in a large number of eukaryotic proteins. As these repeats are often highly diverged, the prediction of HEAT or ARM domains can be challenging. Except for the most clear-cut cases, identification at the individual repeat level is indispensable, in particular for determining domain boundaries. However, methods using single sequence queries do not have the sensitivity required to deal with more divergent repeats and, when applied to proteins with known structures, in some cases failed to detect a single repeat. Methodology and Principal Findings Testing algorithms which use multiple sequence alignments as queries, we found two of them, HHpred and COACH, to detect HEAT and ARM repeats with greatly enhanced sensitivity. Calibration against experimentally determined structures suggests the use of three score classes with increasing confidence in the prediction, and prediction thresholds for each method. When we applied a new protocol using both HHpred and COACH to these structures, it detected 82% of HEAT repeats and 90% of ARM repeats, with the minimum for a given protein of 57% for HEAT repeats and 60% for ARM repeats. Application to bona fide HEAT and ARM proteins or domains indicated that similar numbers can be expected for the full complement of HEAT/ARM proteins. A systematic screen of the Protein Data Bank for false positive hits revealed their number to be low, in particular for ARM repeats. Double false positive hits for a given protein were rare for HEAT and not at all observed for ARM repeats. In combination with fold prediction and consistency checking (multiple sequence alignments, secondary structure prediction, and position analysis), repeat prediction with the new HHpred/COACH protocol dramatically improves prediction in the twilight zone of fold prediction methods, as well as the delineation of HEAT/ARM domain boundaries. Significance A protocol is presented for the identification of individual HEAT or ARM repeats which is straightforward to implement. It provides high sensitivity at a low false positive rate and will therefore greatly enhance the accuracy of predictions of HEAT and ARM domains. PMID:19777061

  14. Paracheck Pf compared with microscopy for diagnosis of Plasmodium falciparum malaria among children in Tanga City, north-eastern Tanzania.

    PubMed

    Kamugisha, M L; Msangeni, H; Beale, E; Malecela, E K; Akida, J; Ishengoma, D R S; Lemnge, M M

    2008-01-01

    Malaria is a major public health problem particularly in rural Sub-Saharan Africa. In most urban areas, malaria transmission intensity is low thus monitoring trends using reliable tools is crucial to provide vital information for future management of the disease. Rapid diagnostic tests (RDT) such as Paracheck Pf are now increasingly adopted for Plasmodium falciparum malaria diagnosis and are advantageous and cost effective alternative to microscopy. This cross sectional survey was carried out during June 2005 to determine the prevalence of malaria in an urban setting and compare microscopy diagnosis versus Paracheck Pf for detecting Plasmodium falciparum. Blood samples from a total of 301 children (< 10 years) attending outpatient clinic at Makorora Health Centre, in Tanga, Tanzania were examined for the presence of malaria. Twenty-nine (9.6%) of the children were positive to malaria by microscopy while 30 (10.0%) were positive by Paracheck test. Three out of 30 positive cases detected by Paracheck were negative by microscopy; thus considered to be false positive results. For the 271 Paracheck Pf negative cases, 2 were positive by microscopy; yielding 2 false negative results. Paracheck Pf sensitivity and specificity were 93.1% and 98.9%, respectively. P. falciparum was the only malarial species observed among the 29 microscopy positive cases. The prevalence of anaemia among the children was 53.16%. These findings indicate a low prevalence of malaria in Tanga City and that Paracheck Pf can be an effective tool for malaria diagnosis.

  15. The Illusion of the Positive: The impact of natural and induced mood on older adults’ false recall

    PubMed Central

    Emery, Lisa; Hess, Thomas M.; Elliot, Tonya

    2012-01-01

    Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults’ information processing and potentially increase underlying cognitive age differences. PMID:22292431

  16. The illusion of the positive: the impact of natural and induced mood on older adults' false recall.

    PubMed

    Emery, Lisa; Hess, Thomas M; Elliot, Tonya

    2012-11-01

    Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995 , Journal of Experimental Psychology: Learning, Memory, and Cognition, 21, 803) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults' information processing and potentially increase underlying cognitive age differences.

  17. Prehospital Acute ST-Elevation Myocardial Infarction Identification in San Diego: A Retrospective Analysis of the Effect of a New Software Algorithm.

    PubMed

    Coffey, Christanne; Serra, John; Goebel, Mat; Espinoza, Sarah; Castillo, Edward; Dunford, James

    2018-05-03

    A significant increase in false positive ST-elevation myocardial infarction (STEMI) electrocardiogram interpretations was noted after replacement of all of the City of San Diego's 110 monitor-defibrillator units with a new brand. These concerns were brought to the manufacturer and a revised interpretive algorithm was implemented. This study evaluated the effects of a revised interpretation algorithm to identify STEMI when used by San Diego paramedics. Data were reviewed 6 months before and 6 months after the introduction of a revised interpretation algorithm. True-positive and false-positive interpretations were identified. Factors contributing to an incorrect interpretation were assessed and patient demographics were collected. A total of 372 (234 preimplementation, 138 postimplementation) cases met inclusion criteria. There was a significant reduction in false positive STEMI (150 preimplementation, 40 postimplementation; p < 0.001) after implementation. The most common factors resulting in false positive before implementation were right bundle branch block, left bundle branch block, and atrial fibrillation. The new algorithm corrected for these misinterpretations with most postimplementation false positives attributed to benign early repolarization and poor data quality. Subsequent follow-up at 10 months showed maintenance of the observed reduction in false positives. This study shows that introducing a revised 12-lead interpretive algorithm resulted in a significant reduction in the number of false positive STEMI electrocardiogram interpretations in a large urban emergency medical services system. Rigorous testing and standardization of new interpretative software is recommended before introduction into a clinical setting to prevent issues resulting from inappropriate cardiac catheterization laboratory activations. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. True detection limits in an experimental linearly heteroscedastic system.. Part 2

    NASA Astrophysics Data System (ADS)

    Voigtman, Edward; Abraham, Kevin T.

    2011-11-01

    Despite much different processing of the experimental fluorescence detection data presented in Part 1, essentially the same estimates were obtained for the true theoretical Currie decision levels ( YC and XC) and true Currie detection limits ( YD and XD). The obtained experimental values, for 5% probability of false positives and 5% probability of false negatives, were YC = 56.0 mV, YD = 125. mV, XC = 0.132 μg/mL and XD = 0.293 μg/mL. For 5% probability of false positives and 1% probability of false negatives, the obtained detection limits were YD = 158 . mV and XD = 0.371 μg/mL. Furthermore, by using bootstrapping methodology on the experimental data for the standards and the analytical blank, it was possible to validate previously published experimental domain expressions for the decision levels ( yC and xC) and detection limits ( yD and xD). This was demonstrated by testing the generated decision levels and detection limits for their performance in regard to false positives and false negatives. In every case, the obtained numbers of false negatives and false positives were as specified a priori.

  19. Is it necessary to remove the seminal vesicles completely at radical prostatectomy? decision curve analysis of European Society of Urologic Oncology criteria.

    PubMed

    Secin, Fernando P; Bianco, Fernando J; Cronin, Angel; Eastham, James A; Scardino, Peter T; Guillonneau, Bertrand; Vickers, Andrew J

    2009-02-01

    A publication on behalf of the European Society of Urological Oncology questioned the need for removing the seminal vesicles during radical prostatectomy in patients with prostate specific antigen less than 10 ng/ml except when biopsy Gleason score is greater than 6 or there are greater than 50% positive biopsy cores. We applied the European Society of Urological Oncology algorithm to an independent data set to determine its predictive value. Data on 1,406 men who underwent radical prostatectomy and seminal vesicle removal between 1998 and 2004 were analyzed. Patients with and without seminal vesicle invasion were classified as positive or negative according to the European Society of Urological Oncology algorithm. Of 90 cases with seminal vesicle invasion 81 (6.4%) were positive for 90% sensitivity, while 656 of 1,316 without seminal vesicle invasion were negative for 50% specificity. The negative predictive value was 98.6%. In decision analytic terms if the loss in health when seminal vesicles are invaded and not completely removed is considered at least 75 times greater than when removing them unnecessarily, the algorithm proposed by the European Society of Urological Oncology should not be used. Whether to use the European Society of Urological Oncology algorithm depends not only on its accuracy, but also on the relative clinical consequences of false-positive and false-negative results. Our threshold of 75 is an intermediate value that is difficult to interpret, given uncertainties about the benefit of seminal vesicle sparing and harm associated with untreated seminal vesicle invasion. We recommend more formal decision analysis to determine the clinical value of the European Society of Urological Oncology algorithm.

  20. Do Intracerebral Hemorrhage Nonexpanders Actually Expand Into the Ventricular Space?

    PubMed

    Dowlatshahi, Dar; Deshpande, Anirudda; Aviv, Richard I; Rodriguez-Luna, David; Molina, Carlos A; Blas, Yolanda Silva; Dzialowski, Imanuel; Kobayashi, Adam; Boulanger, Jean-Martin; Lum, Cheemun; Gubitz, Gordon J; Padma, Vasantha; Roy, Jayanta; Kase, Carlos S; Bhatia, Rohit; Hill, Michael D; Demchuk, Andrew M

    2018-01-01

    The computed tomographic angiography spot sign as a predictor of hematoma expansion is limited by its modest sensitivity and positive predictive value. It is possible that hematoma expansion in spot-positive patients is missed because of decompression of intracerebral hemorrhage (ICH) into the ventricular space. We hypothesized that revising hematoma expansion definitions to include intraventricular hemorrhage (IVH) expansion will improve the predictive performance of the spot sign. Our objectives were to determine the proportion of ICH nonexpanders who actually have IVH expansion, determine the proportion of false-positive spot signs that have IVH expansion, and compare the known predictive performance of the spot sign to a revised definition incorporating IVH expansion. We analyzed patients from the multicenter PREDICT ICH spot sign study. We defined hematoma expansion as ≥6 mL or ≥33% ICH expansion or >2 mL IVH expansion and compared spot sign performance using this revised definition with the conventional 6 mL/33% definition using receiver operating curve analysis. Of 311 patients, 213 did not meet the 6-mL/33% expansion definition (nonexpanders). Only 13 of 213 (6.1%) nonexpanders had ≥2 mL IVH expansion. Of the false-positive spot signs, 4 of 40 (10%) had >2 mL ventricular expansion. The area under the curve for spot sign to predict significant ICH expansion was 0.65 (95% confidence interval, 0.58-0.72), which was no different than when IVH expansion was added to the definition (area under the curve, 0.66; 95% confidence interval, 0.58-0.71). Although IVH expansion does indeed occur in a minority of ICH nonexpanders, its inclusion into a revised hematoma expansion definition does not alter the predictive performance of the spot sign. © 2017 American Heart Association, Inc.

  1. Interval Breast Cancer Rates and Histopathologic Tumor Characteristics after False-Positive Findings at Mammography in a Population-based Screening Program.

    PubMed

    Hofvind, Solveig; Sagstad, Silje; Sebuødegård, Sofie; Chen, Ying; Roman, Marta; Lee, Christoph I

    2018-04-01

    Purpose To compare rates and tumor characteristics of interval breast cancers (IBCs) detected after a negative versus false-positive screening among women participating in the Norwegian Breast Cancer Screening Program. Materials and Methods The Cancer Registry Regulation approved this retrospective study. Information about 423 445 women aged 49-71 years who underwent 789 481 full-field digital mammographic screening examinations during 2004-2012 was extracted from the Cancer Registry of Norway. Rates and odds ratios of IBC among women with a negative (the reference group) versus a false-positive screening were estimated by using logistic regression models adjusted for age at diagnosis and county of residence. Results A total of 1302 IBCs were diagnosed after 789 481 screening examinations, of which 7.0% (91 of 1302) were detected among women with a false-positive screening as the most recent breast imaging examination before detection. By using negative screening as the reference, adjusted odds ratios of IBCs were 3.3 (95% confidence interval [CI]: 2.6, 4.2) and 2.8 (95% CI: 1.8, 4.4) for women with a false-positive screening without and with needle biopsy, respectively. Women with a previous negative screening had a significantly lower proportion of tumors that were 10 mm or less (14.3% [150 of 1049] vs 50.0% [seven of 14], respectively; P < .01) and grade I tumors (13.2% [147 of 1114] vs 42.9% [six of 14]; P < .01), but a higher proportion of cases with lymph nodes positive for cancer (40.9% [442 of 1080] vs 13.3% [two of 15], respectively; P = .03) compared with women with a previous false-positive screening with benign biopsy. A retrospective review of the screening mammographic examinations identified 42.9% (39 of 91) of the false-positive cases to be the same lesion as the IBC. Conclusion By using a negative screening as the reference, a false-positive screening examination increased the risk of an IBC three-fold. The tumor characteristics of IBC after a negative screening were less favorable compared with those detected after a previous false-positive screening. © RSNA, 2017 Online supplemental material is available for this article.

  2. Collision count in rugby union: A comparison of micro-technology and video analysis methods.

    PubMed

    Reardon, Cillian; Tobin, Daniel P; Tierney, Peter; Delahunt, Eamonn

    2017-10-01

    The aim of our study was to determine if there is a role for manipulation of g force thresholds acquired via micro-technology for accurately detecting collisions in rugby union. In total, 36 players were recruited from an elite Guinness Pro12 rugby union team. Player movement profiles and collisions were acquired via individual global positioning system (GPS) micro-technology units. Players were assigned to a sub-category of positions in order to determine positional collision demands. The coding of collisions by micro-technology at g force thresholds between 2 and 5.5 g (0.5 g increments) was compared with collision coding by an expert video analyst using Bland-Altman assessments. The most appropriate g force threshold (smallest mean difference compared with video analyst coding) was lower for all forwards positions (2.5 g) than for all backs positions (3.5 g). The Bland-Altman 95% limits of agreement indicated that there may be a substantial over- or underestimation of collisions coded via GPS micro-technology when using expert video analyst coding as the reference comparator. The manipulation of the g force thresholds applied to data acquired by GPS micro-technology units based on incremental thresholds of 0.5 g does not provide a reliable tool for the accurate coding of collisions in rugby union. Future research should aim to investigate smaller g force threshold increments and determine the events that cause coding of false positives.

  3. Designing occupancy studies when false-positive detections occur

    USGS Publications Warehouse

    Clement, Matthew

    2016-01-01

    1.Recently, estimators have been developed to estimate occupancy probabilities when false-positive detections occur during presence-absence surveys. Some of these estimators combine different types of survey data to improve estimates of occupancy. With these estimators, there is a tradeoff between the number of sample units surveyed, and the number and type of surveys at each sample unit. Guidance on efficient design of studies when false positives occur is unavailable. 2.For a range of scenarios, I identified survey designs that minimized the mean square error of the estimate of occupancy. I considered an approach that uses one survey method and two observation states and an approach that uses two survey methods. For each approach, I used numerical methods to identify optimal survey designs when model assumptions were met and parameter values were correctly anticipated, when parameter values were not correctly anticipated, and when the assumption of no unmodelled detection heterogeneity was violated. 3.Under the approach with two observation states, false positive detections increased the number of recommended surveys, relative to standard occupancy models. If parameter values could not be anticipated, pessimism about detection probabilities avoided poor designs. Detection heterogeneity could require more or fewer repeat surveys, depending on parameter values. If model assumptions were met, the approach with two survey methods was inefficient. However, with poor anticipation of parameter values, with detection heterogeneity, or with removal sampling schemes, combining two survey methods could improve estimates of occupancy. 4.Ignoring false positives can yield biased parameter estimates, yet false positives greatly complicate the design of occupancy studies. Specific guidance for major types of false-positive occupancy models, and for two assumption violations common in field data, can conserve survey resources. This guidance can be used to design efficient monitoring programs and studies of species occurrence, species distribution, or habitat selection, when false positives occur during surveys.

  4. Accuracy of a Plasmodium falciparum specific histidine-rich protein 2 rapid diagnostic test in the context of the presence of non-malaria fevers, prior anti-malarial use and seasonal malaria transmission.

    PubMed

    Kiemde, Francois; Bonko, Massa Dit Achille; Tahita, Marc Christian; Lompo, Palpouguini; Rouamba, Toussaint; Tinto, Halidou; van Hensbroek, Michael Boele; Mens, Petra F; Schallig, Henk D F H

    2017-07-20

    It remains challenging to distinguish malaria from other fever causing infections, as a positive rapid diagnostic test does not always signify a true active malaria infection. This study was designed to determine the influence of other causes of fever, prior anti-malarial treatment, and a possible seasonality of the performance of a PfHRP2 RDT for the diagnosis of malaria in children under-5 years of age living in a malaria endemic area. A prospective etiology study was conducted in 2015 among febrile children under 5 years of age in Burkina Faso. In order to assess the influence of other febrile illnesses, prior treatment and seasonality on the performance of a PfHRP2 RDT in diagnosing malaria, the RDT results were compared with the gold standard (expert microscopic diagnosis of Plasmodium falciparum) and test results were analysed by assuming that prior anti-malarial use and bacterial/viral infection status would have been known prior to testing. To assess bacterial and viral infection status blood, urine and stool samples were analysed. In total 683 blood samples were analysed with microscopy and RDT-PfHRP2. Plasmodium falciparum malaria was diagnosed in 49.8% (340/683) by microscopy compared to 69.5% (475/683) by RDT-PfHRP2. The RDT-PfHRP2 reported 29.7% (141/475) false positive results and 1.8% (6/340) false negative cases. The RDT-PfHRP2 had a high sensitivity (98.2%) and negative predictive value (97.1%), but a low specificity (58.9%) and positive predictive value (70.3%). Almost 50% of the alternative cause of fever were diagnosed by laboratory testing in the RDT false positive malaria group. The use of a malaria RDT-PfHRP2 in a malaria endemic area may cause misdiagnosis of the actual cause of fever due to false positive test results. The development of a practical diagnostic tool to screen for other causes of fever in malaria endemic areas is required to save lives.

  5. The Effect of Reactive atypia/Inflammation on the Laser-Induced Fluorescence Diagnosis of Non-dysplastic Barrett’s Esophagus

    PubMed Central

    Panjehpour, Masoud; Overholt, Bergein F.; Vo-Dinh, Tuan; Coppola, Domenico

    2012-01-01

    Background and Objectives Differential Normalized Fluorescence (DNF) technique has been used to distinguish high-grade dysplasia from non-dysplastic Barrett’s esophagus. This technology may assist gastroenterologists in targeting biopsies, reducing the number of biopsies using the standard protocol. In the presence of reactive atypia/inflammation, it becomes difficult for the pathologist to differentiate non-dysplastic Barrett’s esophagus from Barrett’s esophagus with low grade dysplasia. Before DNF technique may be used to guide target biopsies, it is critical to know whether reactive atypia/inflammation in non-dysplastic Barrett’s may result in false positives. This study was conducted to determine whether DNF technique is adversely affected by the presence of reactive atypia/inflammation in non-dysplastic Barrett’s esophagus resulting in false positives. Study Design/Materials and Methods 410-nm laser light was used to induce autofluorescence of Barrett's mucosa in 49 patients. The clinical study included 37 males and 12 females. This was a blinded retrospective data analysis study. A total of 303 spectra were collected and matched to non-dysplastic Barrett’s biopsy results. 175 spectra were collected from areas with a pathology of non-dysplastic Barrett’s esophagus with reactive atypia/inflammation. 128 spectra were collected from areas with non-dysplastic Barrett’s esophagus without reactive changes/ inflammation. The spectra were analyzed using the DNF Index at 480 nm and classified as positive or negative using the threshold of −0.75 × 10−03 . Results Using DNF technique, 92.6% of non-dysplastic samples with reactive atypia/inflammation were classified correctly (162/175). 92.2 % of non-dysplastic samples without reactive atypia/inflammation were classified correctly (118/128). Comparing the ratios of false positives among the two sample groups, there was not a statistically significant difference between the two groups. Conclusion Using Differential Normalized Fluorescence technique for classification of non-dysplastic Barrett’s mucosa doesn’t result in false positive readings due to reactive atypia/inflammation. Target biopsies guided by DNF technique may drastically reduce the number of pinch biopsies using the standard biopsy protocol. PMID:22535652

  6. Screening for depression in advanced disease: psychometric properties, sensitivity, and specificity of two items of the Palliative Care Outcome Scale (POS).

    PubMed

    Antunes, Bárbara; Murtagh, Fliss; Bausewein, Claudia; Harding, Richard; Higginson, Irene J

    2015-02-01

    Depression is common among patients with advanced disease but often difficult to detect. To assess the Palliative care Outcome Scale (POS) (10 items) against the Geriatric Depression Scale (GDS)-10 total score and the Hospital Anxiety and Depression Scale (HADS)-Depression subscale total score and determine if the POS has appropriate items to screen for depression among people with advanced disease. This was a secondary analysis performed on five studies. Four psychometric properties were assessed: data quality, scaling assumptions, acceptability, and internal consistency (reliability). Receiver operating characteristic (ROC) curves were used to determine the area under the curve. Sensitivity, specificity, positive and negative predictive values, false positive and negative rates, and positive and negative likelihood ratios were computed. The overall sample had 416 patients from Germany and England: 144 had cancer and 267 had nonmalignant conditions. Prevalence of depression across the sample was 17.5%. Floor and ceiling effects were rare. Cronbach's alpha coefficients for POS items 7 and 8 summed, GDS-10 and HADS-Depression items varied: 0.61 (heart failure) and 0.80 (cancer). Two items combined (Item 7-feeling depressed and Item 8-feeling good about yourself) consistently presented the highest area under the ROC curve, ranging from 0.76 (95% CI 0.60, 0.93) (Germany, lung cancer) to 0.97 (95% CI 0.91, 1.0) (heart failure), highest negative predictive value, and lowest false negative rate. For the overall sample, the cutoff 2/3 presented a negative predictive value of 89.4% (95% CI 84.7, 92.8) and false negative rate of 10.6 (95% CI 7.2, 15.3). POS items 7 and 8 summed are potentially useful to screen for depression in advanced disease populations. Copyright © 2015 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.

  7. Multi-crack imaging using nonclassical nonlinear acoustic method

    NASA Astrophysics Data System (ADS)

    Zhang, Lue; Zhang, Ying; Liu, Xiao-Zhou; Gong, Xiu-Fen

    2014-10-01

    Solid materials with cracks exhibit the nonclassical nonlinear acoustical behavior. The micro-defects in solid materials can be detected by nonlinear elastic wave spectroscopy (NEWS) method with a time-reversal (TR) mirror. While defects lie in viscoelastic solid material with different distances from one another, the nonlinear and hysteretic stress—strain relation is established with Preisach—Mayergoyz (PM) model in crack zone. Pulse inversion (PI) and TR methods are used in numerical simulation and defect locations can be determined from images obtained by the maximum value. Since false-positive defects might appear and degrade the imaging when the defects are located quite closely, the maximum value imaging with a time window is introduced to analyze how defects affect each other and how the fake one occurs. Furthermore, NEWS-TR-NEWS method is put forward to improve NEWS-TR scheme, with another forward propagation (NEWS) added to the existing phases (NEWS and TR). In the added phase, scanner locations are determined by locations of all defects imaged in previous phases, so that whether an imaged defect is real can be deduced. NEWS-TR-NEWS method is proved to be effective to distinguish real defects from the false-positive ones. Moreover, it is also helpful to detect the crack that is weaker than others during imaging procedure.

  8. A statistical model of false negative and false positive detection of phase singularities.

    PubMed

    Jacquemet, Vincent

    2017-10-01

    The complexity of cardiac fibrillation dynamics can be assessed by analyzing the distribution of phase singularities (PSs) observed using mapping systems. Interelectrode distance, however, limits the accuracy of PS detection. To investigate in a theoretical framework the PS false negative and false positive rates in relation to the characteristics of the mapping system and fibrillation dynamics, we propose a statistical model of phase maps with controllable number and locations of PSs. In this model, phase maps are generated from randomly distributed PSs with physiologically-plausible directions of rotation. Noise and distortion of the phase are added. PSs are detected using topological charge contour integrals on regular grids of varying resolutions. Over 100 × 10 6 realizations of the random field process are used to estimate average false negative and false positive rates using a Monte-Carlo approach. The false detection rates are shown to depend on the average distance between neighboring PSs expressed in units of interelectrode distance, following approximately a power law with exponents in the range of 1.14 to 2 for false negatives and around 2.8 for false positives. In the presence of noise or distortion of phase, false detection rates at high resolution tend to a non-zero noise-dependent lower bound. This model provides an easy-to-implement tool for benchmarking PS detection algorithms over a broad range of configurations with multiple PSs.

  9. Overhead longwave infrared hyperspectral material identification using radiometric models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zelinski, M. E.

    Material detection algorithms used in hyperspectral data processing are computationally efficient but can produce relatively high numbers of false positives. Material identification performed as a secondary processing step on detected pixels can help separate true and false positives. This paper presents a material identification processing chain for longwave infrared hyperspectral data of solid materials collected from airborne platforms. The algorithms utilize unwhitened radiance data and an iterative algorithm that determines the temperature, humidity, and ozone of the atmospheric profile. Pixel unmixing is done using constrained linear regression and Bayesian Information Criteria for model selection. The resulting product includes an optimalmore » atmospheric profile and full radiance material model that includes material temperature, abundance values, and several fit statistics. A logistic regression method utilizing all model parameters to improve identification is also presented. This paper details the processing chain and provides justification for the algorithms used. Several examples are provided using modeled data at different noise levels.« less

  10. Development of a computer-aided detection system for lung cancer diagnosis

    NASA Astrophysics Data System (ADS)

    Suzuki, Hideo; Inaoka, Noriko; Takabatake, Hirotsugu; Mori, Masaki; Sasaoka, Soichi; Natori, Hiroshi; Suzuki, Akira

    1992-06-01

    This paper describes a modified system for automatic detection of lung nodules by means of chest x ray image processing techniques. The objective of the system is to help radiologists to improve their accuracy in cancer detection. It is known from retrospective studies of chest x- ray images that radiologists fail to detect about 30 percent of lung cancer cases. A computerized method for detecting lung nodules would be very useful for decreasing the proportion of such oversights. Our proposed system consists of five sub-systems, for image input, lung region determination, nodule detection, rule-based false-positive elimination, and statistical false-positive elimination. In an experiment with the modified system, using 30 lung cancer cases and 78 normal control cases, we obtained figures of 73.3 percent and 89.7 percent for the sensitivity and specificity of the system, respectively. The system has been developed to run on the IBM* PS/55* and IBM RISC System/6000* (RS/6000), and we give the processing time for each platform.

  11. Clinical impact of reducing routine blood culture incubation time from 7 to 5 days.

    PubMed

    Marginson, Michael J; Daveson, Kathryn L; Kennedy, Karina J

    2014-12-01

    The aim of this study was to determine the clinical impact of reducing the blood culture incubation protocol from 7 to 5 days.A laboratory data extraction identified positive blood cultures occurring after 5 or more days of incubation at Canberra Hospital, Australia between 1 January 2001 and 31 August 2011. Isolates were identified as clinically significant using a pre-existing prospective bacteraemia database. Medical records review determined whether the positive result affected clinical management.Positive blood cultures after 5 or more days of incubation accounted for 2.65% (423/15979) of all positive blood cultures, although the majority were false positives or contaminants. Eighty-five were significant/indeterminate, representing an average of eight cases per year or 0.47% (85/15979) of all positive blood cultures sets. Forty-three were isolated for the first time, representing 1.1% of all significant/indeterminate blood culture episodes. Fungi and anaerobic bacteria compromised over 50% of isolates. In 26 cases (2.4 cases per year), the culture result led to a change in patient management.A 7 day incubation protocol is preferable due to late isolation of organisms; however, if space is required to accommodate increasing blood culture numbers, reducing to a 5 or 6 day protocol would miss only a small percentage of clinically significant isolates.

  12. High-resolution multi-band imaging for validation and characterization of small Kepler planets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Everett, Mark E.; Silva, David R.; Barclay, Thomas

    2015-02-01

    High-resolution ground-based optical speckle and near-infrared adaptive optics images are taken to search for stars in close angular proximity to host stars of candidate planets identified by the NASA Kepler Mission. Neighboring stars are a potential source of false positive signals. These stars also blend into Kepler light curves, affecting estimated planet properties, and are important for an understanding of planets in multiple star systems. Deep images with high angular resolution help to validate candidate planets by excluding potential background eclipsing binaries as the source of the transit signals. A study of 18 Kepler Object of Interest stars hosting amore » total of 28 candidate and validated planets is presented. Validation levels are determined for 18 planets against the likelihood of a false positive from a background eclipsing binary. Most of these are validated at the 99% level or higher, including five newly validated planets in two systems: Kepler-430 and Kepler-431. The stellar properties of the candidate host stars are determined by supplementing existing literature values with new spectroscopic characterizations. Close neighbors of seven of these stars are examined using multi-wavelength photometry to determine their nature and influence on the candidate planet properties. Most of the close neighbors appear to be gravitationally bound secondaries, while a few are best explained as closely co-aligned field stars. Revised planet properties are derived for each candidate and validated planet, including cases where the close neighbors are the potential host stars.« less

  13. [Analysis of false-positive reaction for bacterial detection of blood samples with the automated microbial detection system BacT/ALERT 3D].

    PubMed

    Zhu, Li-Wei; Yang, Xue-Mei; Xu, Xiao-Qin; Xu, Jian; Lu, Huang-Jun; Yan, Li-Xing

    2008-10-01

    This study was aimed to analyze the results of false positive reaction in bacterial detection of blood samples with BacT/ALERT 3D system, to evaluate the specificity of this system, and to decrease the false positive reaction. Each reaction flasks in past five years were processed for bacteria isolation and identification. When the initial cultures were positive, the remaining samples and the corresponding units were recultured if still available. 11395 blood samples were detected. It is worthy of note that the incubator temperature should be stabilized, avoiding fluctuation; when the cultures were alarmed, the reaction flasks showed be kept some hours for further incubation so as to trace a sharply increasing signal to support the judgement of true bacterial growth. The results indicated that 122 samples (1.07%) wee positive at initial culture, out of them 107 samples (88.7%) were found bacterial, and 15 samples (12.3%) were found nothing. The detection curves of positive samples resulted from bacterial growth showed ascent. In conclusion, maintenance of temperature stability and avoidance of temperature fluctuation in incubator could decrease the occurrence of false-positive reaction in detection process. The reaction flasks with positive results at initial culture should be recultured, and whether existence of a sharply ascending logarilhimic growth phase in bacterial growth curve should be further detected, which are helpful to distinguish false-positive reactions from true positive, and thus increase the specificity of the BacT/ALERT system.

  14. PREDICTING ABUSE POTENTIAL OF STIMULANTS AND OTHER DOPAMINERGIC DRUGS: OVERVIEW AND RECOMMENDATIONS

    PubMed Central

    Huskinson, Sally L.; Naylor, Jennifer E.; Rowlett, James K.; Freeman, Kevin B.

    2014-01-01

    Examination of a drug’s abuse potential at multiple levels of analysis (molecular/cellular action, whole-organism behavior, epidemiological data) is an essential component to regulating controlled substances under the Controlled Substances Act (CSA). We reviewed studies that examined several central nervous system (CNS) stimulants, focusing on those with primarily dopaminergic actions, in drug self-administration, drug discrimination, and physical dependence. For drug self-administration and drug discrimination, we distinguished between experiments conducted with rats and nonhuman primates (NHP) to highlight the common and unique attributes of each model in the assessment of abuse potential. Our review of drug self-administration studies suggests that this procedure is important in predicting abuse potential of dopaminergic compounds, but there were many false positives. We recommended that tests to determine how reinforcing a drug is relative to a known drug of abuse may be more predictive of abuse potential than tests that yield a binary, yes-or-no classification. Several false positives also occurred with drug discrimination. With this procedure, we recommended that future research follow a standard decision-tree approach that may require examining the drug being tested for abuse potential as the training stimulus. This approach would also allow several known drugs of abuse to be tested for substitution, and this may reduce false positives. Finally, we reviewed evidence of physical dependence with stimulants and discussed the feasibility of modeling these phenomena in nonhuman animals in a rational and practical fashion. PMID:24662599

  15. DNA sequencing of maternal plasma reliably identifies trisomy 18 and trisomy 13 as well as Down syndrome: an international collaborative study

    PubMed Central

    Palomaki, Glenn E.; Deciu, Cosmin; Kloza, Edward M.; Lambert-Messerlian, Geralyn M.; Haddow, James E.; Neveux, Louis M.; Ehrich, Mathias; van den Boom, Dirk; Bombard, Allan T.; Grody, Wayne W.; Nelson, Stanley F.; Canick, Jacob A.

    2012-01-01

    Purpose: To determine whether maternal plasma cell–free DNA sequencing can effectively identify trisomy 18 and 13. Methods: Sixty-two pregnancies with trisomy 18 and 12 with trisomy 13 were selected from a cohort of 4,664 pregnancies along with matched euploid controls (including 212 additional Down syndrome and matched controls already reported), and their samples tested using a laboratory-developed, next-generation sequencing test. Interpretation of the results for chromosome 18 and 13 included adjustment for CG content bias. Results: Among the 99.1% of samples interpreted (1,971/1,988), observed trisomy 18 and 13 detection rates were 100% (59/59) and 91.7% (11/12) at false-positive rates of 0.28% and 0.97%, respectively. Among the 17 samples without an interpretation, three were trisomy 18. If z-score cutoffs for trisomy 18 and 13 were raised slightly, the overall false-positive rates for the three aneuploidies could be as low as 0.1% (2/1,688) at an overall detection rate of 98.9% (280/283) for common aneuploidies. An independent academic laboratory confirmed performance in a subset. Conclusion: Among high-risk pregnancies, sequencing circulating cell–free DNA detects nearly all cases of Down syndrome, trisomy 18, and trisomy 13, at a low false-positive rate. This can potentially reduce invasive diagnostic procedures and related fetal losses by 95%. Evidence supports clinical testing for these aneuploidies. PMID:22281937

  16. Comparison of acridine orange and Gram stains for detection of microorganisms in cerebrospinal fluid and other clinical specimens.

    PubMed Central

    Lauer, B A; Reller, L B; Mirrett, S

    1981-01-01

    Acridine orange, a fluorochrome strain, is potentially superior to the Gram stain in the direct microscopic examination of clinical specimens because it gives striking differential staining between bacteria and background cells and debris. Its value in clinical laboratories was evaluated by testing 209 cerebrospinal fluids and 288 other body fluids, tissues, and exudates by both techniques. Smears were made in duplicate, fixed with methanol, stained, and examined without knowledge of the result of the companion smear or culture. Overall, acridine orange was slightly more sensitive than the Gram stain (acridine orange, 59.9%; Gram stain, 55.8%) and equally specific in detecting microorganisms. One smear was falsely positive by the Gram stain; none was falsely positive by the acridine orange stain. We conclude that acridine orange staining is a sensitive method for screening clinical specimens and reviewing selected specimens that are purulent, but negative by the Gram stain. Bloody fluids, thick exudates, and other normally difficult-to-read specimens were easily and quickly examined. We recommend, however, that positive smears be reexamined with the Gram stain to confirm the result and determine the Gram reaction of the microorganisms. PMID:6168652

  17. False-Positive Tuberculin Skin Test Results Among Low-Risk Healthcare Workers Following Implementation of Fifty-Dose Vials of Purified Protein Derivative.

    PubMed

    Collins, Jeffrey M; Hunter, Mary; Gordon, Wanda; Kempker, Russell R; Blumberg, Henry M; Ray, Susan M

    2018-06-01

    Following large declines in tuberculosis transmission the United States, large-scale screening programs targeting low-risk healthcare workers are increasingly a source of false-positive results. We report a large cluster of presumed false-positive tuberculin skin test results in healthcare workers following a change to 50-dose vials of Tubersol tuberculin.Infect Control Hosp Epidemiol 2018;39:750-752.

  18. An Evaluation of Unit and ½ Mass Correction Approaches as a Means of Minimizing the False Positives Produced by M+2 species in US EPA Method 200.8 using ICP-MS

    EPA Science Inventory

    Rare earth elements (REE) and certain alkaline earths can produce M+2 interferences in ICP-MS because they have sufficiently low second ionization energies. Four REEs (150Sm, 150Nd, 156Gd and 156Dy) produce false positives on 75As and 78Se and 132Ba can produce a false positive ...

  19. Algorithm of reducing the false positives in IDS based on correlation Analysis

    NASA Astrophysics Data System (ADS)

    Liu, Jianyi; Li, Sida; Zhang, Ru

    2018-03-01

    This paper proposes an algorithm of reducing the false positives in IDS based on correlation Analysis. Firstly, the algorithm analyzes the distinguishing characteristics of false positives and real alarms, and preliminary screen the false positives; then use the method of attribute similarity clustering to the alarms and further reduces the amount of alarms; finally, according to the characteristics of multi-step attack, associated it by the causal relationship. The paper also proposed a reverse causation algorithm based on the attack association method proposed by the predecessors, turning alarm information into a complete attack path. Experiments show that the algorithm simplifies the number of alarms, improve the efficiency of alarm processing, and contribute to attack purposes identification and alarm accuracy improvement.

  20. [Molecular beacon based PNA-FISH method combined with fluorescence scanning for rapid detection of Listeria monocytogenes].

    PubMed

    Wu, Shan; Zhang, Xiaofeng; Shuai, Jiangbing; Li, Ke; Yu, Huizhen; Jin, Chenchen

    2016-07-04

    To simplify the PNA-FISH (Peptide nucleic acid-fluorescence in situ hybridization) test, molecular beacon based PNA probe combined with fluorescence scanning detection technology was applied to replace the original microscope observation to detect Listeria monocytogenes The 5′ end and 3′ end of the L. monocytogenes specific PNA probes were labeled with the fluorescent group and the quenching group respectively, to form a molecular beacon based PNA probe. When PNA probe used for fluorescence scanning and N1 treatment as the control, the false positive rate was 11.4%, and the false negative rate was 0; when N2 treatment as the control, the false positive rate decreased to 4.3%, but the false negative rate rose to 18.6%. When beacon based PNA probe used for fluorescence scanning, taken N1 treatment as blank control, the false positive rate was 8.6%, and the false negative rate was 1.4%; taken N2 treatment as blank control, the false positive rate was 5.7%, and the false negative rate was 1.4%. Compared with PNA probe, molecular beacon based PNA probe can effectively reduce false positives and false negatives. The success rates of hybridization of the two PNA probes were 83.3% and 95.2% respectively; and the rates of the two beacon based PNA probes were 91.7% and 90.5% respectively, which indicated that labeling the both ends of the PNA probe dose not decrease the hybridization rate with the target bacteria. The combination of liquid phase PNA-FISH and fluorescence scanning method, can significantly improve the detection efficiency.

  1. Implications of false-positive results for future cancer screenings.

    PubMed

    Taksler, Glen B; Keating, Nancy L; Rothberg, Michael B

    2018-06-01

    False-positive cancer screening results may affect a patient's willingness to obtain future screening. The authors conducted logistic regression analysis of 450,484 person-years of electronic medical records (2006-2015) in 92,405 individuals aged 50 to 75 years. Exposures were false-positive breast, prostate, or colorectal cancer screening test results (repeat breast imaging or negative breast biopsy ≤3 months after screening mammography, repeat prostate-specific antigen [PSA] test ≤3 months after PSA test result ≥4.0 ng/mL or negative prostate biopsy ≤3 months after any PSA result, or negative colonoscopy [without biopsy/polypectomy] ≤6 months after a positive fecal occult blood test). Outcomes were up-to-date status with breast or colorectal cancer screening. Covariates included prior screening history, clinical information (eg, family history, obesity, and smoking status), comorbidity, and demographics. Women were more likely to be up to date with breast cancer screening if they previously had false-positive mammography findings (adjusted odds ratio [AOR], 1.43 [95% confidence interval, 1.34-1.51] without breast biopsy and AOR, 2.02 [95% confidence interval, 1.56-2.62] with breast biopsy; both P<.001). The same women were more likely to be up to date with colorectal cancer screening (AOR range, 1.25-1.47 depending on breast biopsy; both P<.001). Men who previously had false-positive PSA testing were more likely to be up to date with colorectal cancer screening (AOR, 1.22 [P = .039] without prostate imaging/biopsy and AOR, 1.60 [P = .028] with imaging/biopsy). Results were stronger for individuals with more false-positive results (all P≤.005). However, women with previous false-positive colorectal cancer fecal occult blood test screening results were found to be less likely to be up to date with breast cancer screening (AOR, 0.73; P<.001). Patients who previously had a false-positive breast or prostate cancer screening test were more likely to engage in future screening. Cancer 2018;124:2390-8. © 2018 American Cancer Society. © 2018 American Cancer Society.

  2. Novel shifts in memory research and their impact on the legal process: introduction to the special issue on memory formation and suggestibility in the legal process.

    PubMed

    Otgaar, Henry; Sauerland, Melanie; Petrila, John P

    2013-01-01

    The functioning and frailties of memory are frequently at the centerpiece of much expert testimony about the reliability of eyewitness accounts. Although we have much knowledge about how false memories and suggestibility can affect testimonies, the contributions in this special issue show that when using a sound theoretical framework, novel directions in this field can surface. The papers in this issue can broadly be divided into contributions that are related to: (1) the exact determinants of false memory and suggestibility; (2) new paradigms in legal psychology; (3) positive consequences of memory illusions; and (4) developmental false memory research. Collectively, these contributions have the potential to provide novel shifts in memory research and push this field beyond its current boundaries. Copyright © 2013 John Wiley & Sons, Ltd.

  3. False-Positive Xpert MTB/RIF Results in Retested Patients with Previous Tuberculosis: Frequency, Profile, and Prospective Clinical Outcomes.

    PubMed

    Theron, Grant; Venter, Rouxjeane; Smith, Liezel; Esmail, Aliasgar; Randall, Philippa; Sood, Vishesh; Oelfese, Suzette; Calligaro, Greg; Warren, Robin; Dheda, Keertan

    2018-03-01

    Globally, Xpert MTB/RIF (Xpert) is the most widely used PCR test for the diagnosis of tuberculosis (TB). Positive results in previously treated patients, which are due to old DNA or active disease, are a diagnostic dilemma. We prospectively retested sputum from 238 patients, irrespective of current symptoms, who were previously diagnosed to be Xpert positive and treated successfully. Patients who retested as Xpert positive and culture negative were exhaustively investigated (repeat culture, chest radiography, bronchoscopy with bronchoalveolar lavage, long-term clinical follow-up). We evaluated whether the duration since previous treatment completion, mycobacterial burden (the Xpert cycle threshold [ C T ] value), and reclassification of Xpert-positive results with a very low semiquantitation level to Xpert-negative results reduced the rate of false positivity. A total of 229/238 (96%) of patients were culture negative. Sixteen of 229 (7%) were Xpert positive a median of 11 months (interquartile range, 5 to 19 months) after treatment completion. The specificity was 93% (95% confidence interval [CI], 89 to 96%). Nine of 15 (40%) Xpert-positive, culture-negative patients reverted to Xpert negative after 2 to 3 months (1 patient declined further participation). Patients with false-positive Xpert results had a lower mycobacterial burden than patients with true-positive Xpert results ( C T , 28.7 [95% CI, 27.2 to 30.4] versus 17.6 [95% CI, 16.9 to 18.2]; P < 0.001), an increased likelihood of a chest radiograph not compatible with active TB (5/15 patients versus 0/5 patients; P = 0.026), and less-viscous sputum (15/16 patients versus 2/5 patients whose sputum was graded as mucoid or less; P = 0.038). All patients who initially retested as Xpert positive and culture negative ("Xpert false positive") were clinically well without treatment after follow-up. The duration since the previous treatment poorly predicted false-positive results (a duration of ≤2 years identified only 66% of patients with false-positive results). Reclassifying Xpert-positive results with a very low semiquantitation level to Xpert negative improved the specificity (+3% [95% CI, +2 to +5%]) but reduced the sensitivity (-10% [95% CI, -4 to -15%]). Patients with previous TB retested with Xpert can have false-positive results and thus not require treatment. These data inform clinical practice by highlighting the challenges in interpreting Xpert-positive results, underscore the need for culture, and have implications for next-generation ultrasensitive tests. Copyright © 2018 American Society for Microbiology.

  4. Case Reports of Aripiprazole Causing False-Positive Urine Amphetamine Drug Screens in Children.

    PubMed

    Kaplan, Justin; Shah, Pooja; Faley, Brian; Siegel, Mark E

    2015-12-01

    Urine drug screens (UDSs) are used to identify the presence of certain medications. One limitation of UDSs is the potential for false-positive results caused by cross-reactivity with other substances. Amphetamines have an extensive list of cross-reacting medications. The literature contains reports of false-positive amphetamine UDSs with multiple antidepressants and antipsychotics. We present 2 cases of presumed false-positive UDSs for amphetamines after ingestion of aripiprazole. Case 1 was a 16-month-old girl who accidently ingested 15 to 45 mg of aripiprazole. She was lethargic and ataxic at home with 1 episode of vomiting containing no identifiable tablets. She remained sluggish with periods of irritability and was admitted for observation. UDS on 2 consecutive days came back positive for amphetamines. Case 2 was of a 20-month-old girl who was brought into the hospital after accidental ingestion of an unknown quantity of her father's medications which included aripiprazole. UDS on the first day of admission came back positive only for amphetamines. Confirmatory testing with gas chromatography-mass spectrometry (GC-MS) on the blood and urine samples were also performed for both patients on presentation to detect amphetamines and were subsequently negative. Both patients returned to baseline and were discharged from the hospital. To our knowledge, these cases represent the first reports of false-positive amphetamine urine drug tests with aripiprazole. In both cases, aripiprazole was the drug with the highest likelihood of causing the positive amphetamine screen. The implications of these false-positives include the possibility of unnecessary treatment and monitoring of patients. Copyright © 2015 by the American Academy of Pediatrics.

  5. Determining decision thresholds and evaluating indicators when conservation status is measured as a continuum.

    PubMed

    Connors, B M; Cooper, A B

    2014-12-01

    Categorization of the status of populations, species, and ecosystems underpins most conservation activities. Status is often based on how a system's current indicator value (e.g., change in abundance) relates to some threshold of conservation concern. Receiver operating characteristic (ROC) curves can be used to quantify the statistical reliability of indicators of conservation status and evaluate trade-offs between correct (true positive) and incorrect (false positive) classifications across a range of decision thresholds. However, ROC curves assume a discrete, binary relationship between an indicator and the conservation status it is meant to track, which is a simplification of the more realistic continuum of conservation status, and may limit the applicability of ROC curves in conservation science. We describe a modified ROC curve that treats conservation status as a continuum rather than a discrete state. We explored the influence of this continuum and typical sources of variation in abundance that can lead to classification errors (i.e., random variation and measurement error) on the true and false positive rates corresponding to varying decision thresholds and the reliability of change in abundance as an indicator of conservation status, respectively. We applied our modified ROC approach to an indicator of endangerment in Pacific salmon (Oncorhynchus nerka) (i.e., percent decline in geometric mean abundance) and an indicator of marine ecosystem structure and function (i.e., detritivore biomass). Failure to treat conservation status as a continuum when choosing thresholds for indicators resulted in the misidentification of trade-offs between true and false positive rates and the overestimation of an indicator's reliability. We argue for treating conservation status as a continuum when ROC curves are used to evaluate decision thresholds in indicators for the assessment of conservation status. © 2014 Society for Conservation Biology.

  6. False-Positive Gen-Probe Direct Mycobacterium tuberculosis Amplification Test Results for Patients with Pulmonary M. kansasii and M. avium Infections

    PubMed Central

    Jorgensen, James H.; Salinas, Jesse R.; Paxson, Rosemary; Magnon, Karen; Patterson, Jan E.; Patterson, Thomas F.

    1999-01-01

    The Gen-Probe Amplified Mycobacterium Tuberculosis Direct (MTD) test has been approved for use in the United States for the rapid diagnosis of pulmonary tuberculosis in patients with acid-fast smear-positive sputum samples since 1996. Four patients infected with human immunodeficiency virus and one chronic pulmonary-disease patient seen in our institutions with abnormal chest radiographs and fluorochrome stain-positive sputa were evaluated for tuberculosis, including performance of the MTD test on expectorated sputum samples. Three of these five patients’ sputa were highly smear-positive (i.e., more than 100 bacilli per high-power field), while two patient’s sputa contained 1 to 10 bacilli per field. MTD results on sputum specimens from these patients ranged from 43,498 to 193,858 relative light units (RLU). Gen-Probe has defined values of at least 30,000 RLU as indicative of a positive test, i.e., the presence of Mycobacterium tuberculosis RNA. Four of the patients’ sputum cultures yielded growth of M. kansasii within 6 to 12 days, and the fifth produced growth of M. avium only. One patient’s culture contained both M. kansasii and M. avium, but none of the initial or follow-up cultures from these five patients revealed M. tuberculosis. However, subsequent cultures from three of the patients again revealed M. kansasii. During the period of this study, in which MTD tests were performed on smear-positive sputum specimens from 82 patients, four of seven patients with culture-proven M. kansasii pulmonary infections yielded one or more false-positive MTD tests. The MTD sensitivity observed in this study was 93.8%, and the specificity was 85.3%. Five cultures of M. kansasii (including three of these patients’ isolates and M. kansasii ATCC 12478), and cultures of several other species were examined at densities of 105 to 107 viable CFU/ml by the MTD test. All five isolates of M. kansasii and three of three isolates of M. simiae yielded false-positive test results, with readings of 75,191 to 335,591 RLU. These findings indicate that low-level false-positive MTD results can occur due to the presence of M. kansasii, M. avium, and possibly other Mycobacterium species other than M. tuberculosis in sputum. Low-level positive MTD results of 30,000 to 500,000 RLU should be interpreted in light of these findings. It remains to be determined if the enhanced MTD test (MTD 2) recently released by Gen-Probe will provide greater specificity than that observed in this report with its first-generation test. PMID:9854086

  7. Effect of protocol-related variables and women's characteristics on the cumulative false-positive risk in breast cancer screening

    PubMed Central

    Román, R.; Sala, M.; Salas, D.; Ascunce, N.; Zubizarreta, R.; Castells, X.

    2012-01-01

    Background: Reducing the false-positive risk in breast cancer screening is important. We examined how the screening-protocol and women's characteristics affect the cumulative false-positive risk. Methods: This is a retrospective cohort study of 1 565 364 women aged 45–69 years who underwent 4 739 498 screening mammograms from 1990 to 2006. Multilevel discrete hazard models were used to estimate the cumulative false-positive risk over 10 sequential mammograms under different risk scenarios. Results: The factors affecting the false-positive risk for any procedure and for invasive procedures were double mammogram reading [odds ratio (OR) = 2.06 and 4.44, respectively], two mammographic views (OR = 0.77 and 1.56, respectively), digital mammography (OR = 0.83 for invasive procedures), premenopausal status (OR = 1.31 and 1.22, respectively), use of hormone replacement therapy (OR = 1.03 and 0.84, respectively), previous invasive procedures (OR = 1.52 and 2.00, respectively), and a familial history of breast cancer (OR = 1.18 and 1.21, respectively). The cumulative false-positive risk for women who started screening at age 50–51 was 20.39% [95% confidence interval (CI) 20.02–20.76], ranging from 51.43% to 7.47% in the highest and lowest risk profiles, respectively. The cumulative risk for invasive procedures was 1.76% (95% CI 1.66–1.87), ranging from 12.02% to 1.58%. Conclusions: The cumulative false-positive risk varied widely depending on the factors studied. These findings are relevant to provide women with accurate information and to improve the effectiveness of screening programs. PMID:21430183

  8. Factors associated with a second deferral among donors eligible for re-entry after a false-positive screening test for syphilis, HCV, HBV and HIV.

    PubMed

    Grégoire, Y; Germain, M; Delage, G

    2018-05-01

    Since 25 May 2010, all donors at our blood centre who tested false-positive for HIV, HBV, HCV or syphilis are eligible for re-entry after further testing. Donors who have a second false-positive screening test, either during qualification for or after re-entry, are deferred for life. This study reports on factors associated with the occurrence of such deferrals. Rates of second false-positive results were compared by year of deferral, transmissible disease marker, gender, age, donor status (new or repeat) and testing platform (same or different) both at qualification for re-entry and afterwards. Chi-square tests were used to compare proportions. Cox regression was used for multivariate analyses. Participation rates in the re-entry programme were 42·1%: 25·6% failed to qualify for re-entry [different platform: 2·7%; same platform: 42·9% (P < 0·0001)]. After re-entry, rates of deferral for second false-positive results were 8·4% after 3 years [different platform: 1·8%; same platform: 21·4% (P < 0·0001)]. Deferral rates were higher for HIV and HCV than for HBV at qualification when tested on the same platform. The risk, when analysed by multivariate analyses, of a second deferral for a false-positive result, both at qualification and 3 years after re-entry, was lower for donors deferred on a different platform; this risk was higher for HIV, HCV and syphilis than for HBV and for new donors if tested on the same platform. Re-entry is more often successful when donors are tested on a testing platform different from the one on which they obtained their first false-positive result. © 2018 International Society of Blood Transfusion.

  9. An Evaluation of Unit and ½ Mass Correction Approaches as a Means of Minimizing the False Positives Produced by M+2 species in US EPA Method 200.8 using ICP-MS (webinar presentation)

    EPA Science Inventory

    Rare earth elements (REE) and certain alkaline earths can produce M+2 interferences in ICP-MS because they have sufficiently low second ionization energies. Four REEs (150Sm, 150Nd, 156Gd and 156Dy) produce false positives on 75As and 78Se and 132Ba can produce a false positive ...

  10. Accuracy of administrative data versus clinical data to evaluate carotid endarterectomy and carotid stenting

    PubMed Central

    Bensley, Rodney P; Yoshida, Shunsuke; Lo, Ruby C; Fokkema, Margriet; Hamdan, Allen D; Wyers, Mark C; Chaikof, Elliot L; Schermerhorn, Marc L

    2013-01-01

    Objectives Administrative data have been used to compare carotid endarterectomy (CEA) and carotid artery stenting (CAS). However, there are limitations in defining symptom status, CMS high-risk status, as well as complications. Therefore, we did a direct comparison between administrative data and physician chart review as well as between data collected for the National Surgical Quality Improvement Program (NSQIP) and physician chart review for CEA and CAS. Methods We performed an outcomes analysis on all CEA and CAS procedures from 2005–2011. We obtained ICD-9 diagnosis codes from hospital discharge records regarding symptom status, high-risk status, and perioperative stroke. We also obtained data on all CEA patients submitted to NSQIP over the same time period. A physician then performed a chart review of the same patients to determine symptom status, high-risk status, and perioperative strokes and the results were compared. Results We identified 1342 patients who underwent CEA or CAS between 2005–2011 and 392 patients who underwent CEA that were submitted to NSQIP. Administrative data identified fewer symptomatic patients (17.0% vs. 34.0%), fewer physiologic high-risk patients (9.3% vs. 23.0%), fewer anatomic high-risk patients (0% vs. 15.2%), and a similar proportion of perioperative strokes (1.9% vs. 2.0%). However, administrative data identified 8 false positive and 9 false negative perioperative strokes. NSQIP data identified more symptomatic patients compared to chart review (44.1% vs. 30.3%), fewer physiologic high-risk patients (13.0% vs. 18.6%), fewer anatomic high-risk patients (0% vs. 6.6%), and a similar proportion of perioperative strokes (1.5% vs. 1.8%, only 1 false negative stroke and no false positives). Conclusions Administrative data are unreliable for determining symptom status, high-risk status, and perioperative stroke and should not be used to analyze CEA and CAS. NSQIP data do not adequately identify high-risk patients, but do accurately identify perioperative strokes and to a lesser degree, symptom status. PMID:23490294

  11. Upper Limb Neural Tension and Seated Slump Tests: The False Positive Rate among Healthy Young Adults without Cervical or Lumbar Symptoms

    PubMed Central

    Davis, D. Scott; Anderson, Ila Beth; Carson, Mary Grace; Elkins, Caroline L.; Stuckey, Lindsey B.

    2008-01-01

    This study examined the false positive rate of the upper limb neural tension test (ULNTT) and seated slump test (SST) among healthy young adults with no history of cervical, lumbar, or peripheral symptoms. Eighty-four subjects (27 men and 57 women) with a mean age of 22.9 years participated in the investigation. All participants completed a screening questionnaire designed to exclude subjects with a history of cervical or lumbar spine pain or injury, or upper or lower extremity neurological symptoms. The ULNTT and the SST were performed on the left upper and lower extremity of each participant. Of the 84 participants tested, 73 (86.9%) were found to have a positive ULNTT at some point in the available range of elbow extension. Twenty-eight (33.3%) of the 84 subjects had a positive SST at some point in the available range of knee extension. The mean knee extension angle for those subjects with a positive SST was 15.1° with a 95% confidence interval (CI) of 12.3 and 19.7°. The mean elbow extension angle for those with a positive ULNTT was 49.4° with a 95% CI of 44.8 and 54.0°. The number of positive tests for both the ULNTT and the SST was found to be high in this sample of asymptomatic healthy young adults. Based on the results of this investigation, the authors suggest that the current criteria for determining a positive test for both the ULNTT and the SST should be examined using the proposed range of motion cut-off scores. PMID:19119402

  12. Upper Limb Neural Tension and Seated Slump Tests: The False Positive Rate among Healthy Young Adults without Cervical or Lumbar Symptoms.

    PubMed

    Davis, D Scott; Anderson, Ila Beth; Carson, Mary Grace; Elkins, Caroline L; Stuckey, Lindsey B

    2008-01-01

    This study examined the false positive rate of the upper limb neural tension test (ULNTT) and seated slump test (SST) among healthy young adults with no history of cervical, lumbar, or peripheral symptoms. Eighty-four subjects (27 men and 57 women) with a mean age of 22.9 years participated in the investigation. All participants completed a screening questionnaire designed to exclude subjects with a history of cervical or lumbar spine pain or injury, or upper or lower extremity neurological symptoms. The ULNTT and the SST were performed on the left upper and lower extremity of each participant. Of the 84 participants tested, 73 (86.9%) were found to have a positive ULNTT at some point in the available range of elbow extension. Twenty-eight (33.3%) of the 84 subjects had a positive SST at some point in the available range of knee extension. The mean knee extension angle for those subjects with a positive SST was 15.1 degrees with a 95% confidence interval (CI) of 12.3 and 19.7 degrees . The mean elbow extension angle for those with a positive ULNTT was 49.4 degrees with a 95% CI of 44.8 and 54.0 degrees . The number of positive tests for both the ULNTT and the SST was found to be high in this sample of asymptomatic healthy young adults. Based on the results of this investigation, the authors suggest that the current criteria for determining a positive test for both the ULNTT and the SST should be examined using the proposed range of motion cut-off scores.

  13. False memory and level of processing effect: an event-related potential study.

    PubMed

    Beato, Maria Soledad; Boldini, Angela; Cadavid, Sara

    2012-09-12

    Event-related potentials (ERPs) were used to determine the effects of level of processing on true and false memory, using the Deese-Roediger-McDermott (DRM) paradigm. In the DRM paradigm, lists of words highly associated to a single nonpresented word (the 'critical lure') are studied and, in a subsequent memory test, critical lures are often falsely remembered. Lists with three critical lures per list were auditorily presented here to participants who studied them with either a shallow (saying whether the word contained the letter 'o') or a deep (creating a mental image of the word) processing task. Visual presentation modality was used on a final recognition test. True recognition of studied words was significantly higher after deep encoding, whereas false recognition of nonpresented critical lures was similar in both experimental groups. At the ERP level, true and false recognition showed similar patterns: no FN400 effect was found, whereas comparable left parietal and late right frontal old/new effects were found for true and false recognition in both experimental conditions. Items studied under shallow encoding conditions elicited more positive ERP than items studied under deep encoding conditions at a 1000-1500 ms interval. These ERP results suggest that true and false recognition share some common underlying processes. Differential effects of level of processing on true and false memory were found only at the behavioral level but not at the ERP level.

  14. Oxybuprocaine induces a false-positive response in immunochromatographic SAS Adeno Test.

    PubMed

    Hoshino, Takeshi; Takanashi, Taiji; Okada, Morio; Uchida, Sunao

    2002-04-01

    To investigate whether a solution of oxybuprocaine hydrochloride, 0.4%, results in a false-positive response in an immunochromatographic SAS Adeno Test. Experimental study. Physiologic saline and 2% lidocaine. Each chemical (100 microl) was diluted in a transport medium. Five drops (200 microl) of the resultant solution were dispensed into the round sample well of a test device. Fifteen samples were tested in each group. Ten minutes after the start of the test, a colored line in the "specimen" portion of the test membrane was visually read as positive or negative by a masked technician. No positive reaction was observed in the control groups (physiologic saline and lidocaine). A false-positive reaction was observed in six samples (33.3%) in the oxybuprocaine group. The positive rate was significantly higher in the oxybuprocaine group compared with those in control groups (P = 0.0062, Fisher's extract probability test). Oxybuprocaine may induce a false-positive reaction in an immunochromatographic SAS Adeno Test. We recommend the use of lidocaine, instead of oxybuprocaine, for local anesthesia in taking eye swabs from patients with suspected adenovirus infection.

  15. Do positive schizotypal symptoms predict false perceptual experiences in nonclinical populations?

    PubMed

    Tsakanikos, Elias; Reed, Phil

    2005-12-01

    We examined whether positive schizotypy (i.e., reports of hallucinatory and delusional-like experiences) in nonclinical participants could predict false perceptual experiences during detection of fast-moving words beyond a possible response bias. The participants (N = 160) were assigned to one of two conditions: they were asked either to make presence/absence judgments (loose criterion) or to read aloud every detected word (strict criterion). Regression analysis showed that high levels of positive schizotypy predicted false alarms in the loose condition and false perceptions of words in the strict condition. The obtained effects were independent of detection accuracy, task order, impulsivity, and social desirability. We discuss the results in the context of information processing biases linked to the positive symptomatology of schizophrenia. Clinical and theoretical implications are also considered.

  16. False Memory in Adults With ADHD: A Comparison Between Subtypes and Normal Controls.

    PubMed

    Soliman, Abdrabo Moghazy; Elfar, Rania Mohamed

    2017-10-01

    To examine the performance on the Deese-Roediger-McDermott task of adults divided into ADHD subtypes and compares their performance to that of healthy controls to examine whether adults with ADHD are more susceptible to the production of false memories under experimental conditions. A total of 128 adults with ADHD (50% females), classified into three Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV-TR) subtypes, were compared with 48 controls. The results indicated that the ADHD participants recalled and recognized fewer studied words than the controls, the ADHD groups produced more false memories than the control group, no differences in either the false positives or the false negatives. The ADHD-combined (ADHD-CT) group recognized significantly more critical words than the control, ADHD-predominantly inattentive (ADHD-IA), and ADHD-predominantly hyperactive-impulsive (ADHD-HI) groups. The ADHD groups recalled and recognized more false positives, were more confident in their false responses, and displayed more knowledge corruption than the controls. The ADHD-CT group recalled and recognized more false positives than the other ADHD groups. The adults with ADHD have more false memories than the controls and that false memory formation varied with the ADHD subtypes.

  17. VarBin, a novel method for classifying true and false positive variants in NGS data

    PubMed Central

    2013-01-01

    Background Variant discovery for rare genetic diseases using Illumina genome or exome sequencing involves screening of up to millions of variants to find only the one or few causative variant(s). Sequencing or alignment errors create "false positive" variants, which are often retained in the variant screening process. Methods to remove false positive variants often retain many false positive variants. This report presents VarBin, a method to prioritize variants based on a false positive variant likelihood prediction. Methods VarBin uses the Genome Analysis Toolkit variant calling software to calculate the variant-to-wild type genotype likelihood ratio at each variant change and position divided by read depth. The resulting Phred-scaled, likelihood-ratio by depth (PLRD) was used to segregate variants into 4 Bins with Bin 1 variants most likely true and Bin 4 most likely false positive. PLRD values were calculated for a proband of interest and 41 additional Illumina HiSeq, exome and whole genome samples (proband's family or unrelated samples). At variant sites without apparent sequencing or alignment error, wild type/non-variant calls cluster near -3 PLRD and variant calls typically cluster above 10 PLRD. Sites with systematic variant calling problems (evident by variant quality scores and biases as well as displayed on the iGV viewer) tend to have higher and more variable wild type/non-variant PLRD values. Depending on the separation of a proband's variant PLRD value from the cluster of wild type/non-variant PLRD values for background samples at the same variant change and position, the VarBin method's classification is assigned to each proband variant (Bin 1 to Bin 4). Results To assess VarBin performance, Sanger sequencing was performed on 98 variants in the proband and background samples. True variants were confirmed in 97% of Bin 1 variants, 30% of Bin 2, and 0% of Bin 3/Bin 4. Conclusions These data indicate that VarBin correctly classifies the majority of true variants as Bin 1 and Bin 3/4 contained only false positive variants. The "uncertain" Bin 2 contained both true and false positive variants. Future work will further differentiate the variants in Bin 2. PMID:24266885

  18. Final Report: Computer-aided Human Centric Cyber Situation Awareness

    DTIC Science & Technology

    2016-03-20

    logs, OS audit trails, vulnerability reports, and packet dumps ), weeding out the false positives, grouping the related indicators so that different...short time duration of each visual stimulus in an fMRI study, we have designed “network security analysis cards ” that require the subject to...determine whether alerts in the cards indicate malicious events. Two types of visual displays of alerts (i.e., tabular display and node-link display) are

  19. Phase 1 Testing of Bioflash Technology for White Powder Identification

    DTIC Science & Technology

    2012-06-01

    limit of detection for the test bed system for powdered spores of Bacillus anthracis and Bacillus subtilis , and (2) to determine if common nonhazardous... Bacillus subtilis ; and (2) if common nonhazardous white powders trigger a false positive response or subsequently interfere with the ability of the...Isolated from Flour and Ropy Bread. Letters in App Microbiol. 2003, 37, 169-173. Te Giffel, M.C. Incidence of Bacillus cereus and Bacillus subtilis in

  20. IgM rheumatoid factor removal and performance of the FTA-ABS (IgM) test in congenital syphilis.

    PubMed

    Meyer, M P; Roditi, D; Louw, S

    1992-08-01

    To determine the performance of the FTA-ABS (IgM) test in congenital syphilis after eliminating interference by IgM rheumatoid factor (RF) and preventing competitive inhibition by IgG. The FTA-ABS (IgM) test was carried out before and after RF removal (achieved by immunoprecipitation of the IgG) in infants with congenital syphilis and controls. Newborns delivered in the Peninsula Maternal and Neonatal Services in Cape Town and infants presenting at Red Cross War Memorial Children's Hospital. Infants with congenital syphilis aged 0-4 months were divided into those with clinical signs at presentation and those who were asymptomatic at delivery. In addition, patients without congenital syphilis but with similar clinical signs at presentation were investigated as were control infants. The diagnosis of congenital syphilis was based on the criteria suggested by Kaufman et al (1977). Amongst symptomatic infants with congenital syphilis the FTA-ABS (IgM) test was positive in 34 (92%) of 37 cases prior to abolishing the RF effect and in 29 (78.4%) of 37 cases afterwards (p = 0.19). In 12 cases of congenital syphilis who were asymptomatic at birth, 10 had positive FTA-ABS (IgM) tests before RF removal and only three had positive tests afterwards (p = 0.006). False positive tests were not found amongst 15 symptomatic infants whose clinical features mimicked those of the infants with congenital syphilis. Among 51 healthy infants the test had a false-positive rate of 2% in newborns and 13% in older infants. The false positive reactions were eradicated by IgG precipitation. Following IgG and RF removal there was an improvement in the specificity of the FTA-ABS (IgM) test but this was at the expense of a loss of sensitivity, particularly in asymptomatic newborns. For newborns, if the FTA-ABS (IgM) test was positive, the patient was likely to require treatment for congenital syphilis, regardless of whether the result was due to the presence of RF or specific IgM.

  1. Abort Trigger False Positive and False Negative Analysis Methodology for Threshold-Based Abort Detection

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin J.; Cruz, Jose A.; Johnson Stephen B.; Lo, Yunnhon

    2015-01-01

    This paper describes a quantitative methodology for bounding the false positive (FP) and false negative (FN) probabilities associated with a human-rated launch vehicle abort trigger (AT) that includes sensor data qualification (SDQ). In this context, an AT is a hardware and software mechanism designed to detect the existence of a specific abort condition. Also, SDQ is an algorithmic approach used to identify sensor data suspected of being corrupt so that suspect data does not adversely affect an AT's detection capability. The FP and FN methodologies presented here were developed to support estimation of the probabilities of loss of crew and loss of mission for the Space Launch System (SLS) which is being developed by the National Aeronautics and Space Administration (NASA). The paper provides a brief overview of system health management as being an extension of control theory; and describes how ATs and the calculation of FP and FN probabilities relate to this theory. The discussion leads to a detailed presentation of the FP and FN methodology and an example showing how the FP and FN calculations are performed. This detailed presentation includes a methodology for calculating the change in FP and FN probabilities that result from including SDQ in the AT architecture. To avoid proprietary and sensitive data issues, the example incorporates a mixture of open literature and fictitious reliability data. Results presented in the paper demonstrate the effectiveness of the approach in providing quantitative estimates that bound the probability of a FP or FN abort determination.

  2. Current nonclinical testing paradigm enables safe entry to First-In-Human clinical trials: The IQ consortium nonclinical to clinical translational database.

    PubMed

    Monticello, Thomas M; Jones, Thomas W; Dambach, Donna M; Potter, David M; Bolt, Michael W; Liu, Maggie; Keller, Douglas A; Hart, Timothy K; Kadambi, Vivek J

    2017-11-01

    The contribution of animal testing in drug development has been widely debated and challenged. An industry-wide nonclinical to clinical translational database was created to determine how safety assessments in animal models translate to First-In-Human clinical risk. The blinded database was composed of 182 molecules and contained animal toxicology data coupled with clinical observations from phase I human studies. Animal and clinical data were categorized by organ system and correlations determined. The 2×2 contingency table (true positive, false positive, true negative, false negative) was used for statistical analysis. Sensitivity was 48% with a 43% positive predictive value (PPV). The nonhuman primate had the strongest performance in predicting adverse effects, especially for gastrointestinal and nervous system categories. When the same target organ was identified in both the rodent and nonrodent, the PPV increased. Specificity was 84% with an 86% negative predictive value (NPV). The beagle dog had the strongest performance in predicting an absence of clinical adverse effects. If no target organ toxicity was observed in either test species, the NPV increased. While nonclinical studies can demonstrate great value in the PPV for certain species and organ categories, the NPV was the stronger predictive performance measure across test species and target organs indicating that an absence of toxicity in animal studies strongly predicts a similar outcome in the clinic. These results support the current regulatory paradigm of animal testing in supporting safe entry to clinical trials and provide context for emerging alternate models. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. The Use of Dried Blood Spots: A Potential Tool for the Introduction of a Neonatal Screening Program for Sickle Cell Anemia in Zambia.

    PubMed

    Chindima, Nanjela; Nkhoma, Panji; Sinkala, Musalula; Zulu, Mildred; Kafita, Doris; Simakando, Marah; Mwaba, Florence; Mantina, Hamakwa; Mutale, Mubanga

    2018-01-01

    Sickle cell disease is a group of hemoglobin (Hb) disorders resulting from the inheritance of the sickle β-globin gene. It is the most common pathological Hb mutation worldwide with 75% being born in Sub-Saharan Africa. This study aims to determine if dried blood spots (DBSs) can be used for diagnosis of sickle cell in newborns. In Zambia, there is no neonatal screening program for sickle cell anemia (SCA), yet it has been proved that early diagnosis by newborn screening (NBS) using DBSs and access to comprehensive care results in survival to adulthood of over 96% of sickle cell patients. A cross-sectional study was carried out at the University Teaching Hospital to determine whether DBSs can be used to diagnose sickle cell using Hb electrophoresis. Results from DBSs stored for 2 weeks were then compared to those obtained using freshly collected whole blood. To evaluate performance characteristics, the following values were used: true positive, false positive, true negative, and false negative. Ninety-seven participants were included in this study. DBSs had a sensitivity of 100%, a specificity of 94.7%, positive predictive value of 96.7%, negative predictive value of 100%, overall efficiency of 97.9%, and a Kappa r 2 , P < 0.0001 in comparison to fresh whole blood which we used as the gold standard. The use of DBSs can be recommended for NBS of SCA in Zambia due to its high sensitivity, specificity, and stability of hemoglobin.

  4. A utility/cost analysis of breast cancer risk prediction algorithms

    NASA Astrophysics Data System (ADS)

    Abbey, Craig K.; Wu, Yirong; Burnside, Elizabeth S.; Wunderlich, Adam; Samuelson, Frank W.; Boone, John M.

    2016-03-01

    Breast cancer risk prediction algorithms are used to identify subpopulations that are at increased risk for developing breast cancer. They can be based on many different sources of data such as demographics, relatives with cancer, gene expression, and various phenotypic features such as breast density. Women who are identified as high risk may undergo a more extensive (and expensive) screening process that includes MRI or ultrasound imaging in addition to the standard full-field digital mammography (FFDM) exam. Given that there are many ways that risk prediction may be accomplished, it is of interest to evaluate them in terms of expected cost, which includes the costs of diagnostic outcomes. In this work we perform an expected-cost analysis of risk prediction algorithms that is based on a published model that includes the costs associated with diagnostic outcomes (true-positive, false-positive, etc.). We assume the existence of a standard screening method and an enhanced screening method with higher scan cost, higher sensitivity, and lower specificity. We then assess expected cost of using a risk prediction algorithm to determine who gets the enhanced screening method under the strong assumption that risk and diagnostic performance are independent. We find that if risk prediction leads to a high enough positive predictive value, it will be cost-effective regardless of the size of the subpopulation. Furthermore, in terms of the hit-rate and false-alarm rate of the of the risk prediction algorithm, iso-cost contours are lines with slope determined by properties of the available diagnostic systems for screening.

  5. Evaluation of single-nucleotide polymorphisms as internal controls in prenatal diagnosis of fetal blood groups.

    PubMed

    Doescher, Andrea; Petershofen, Eduard K; Wagner, Franz F; Schunter, Markus; Müller, Thomas H

    2013-02-01

    Determination of fetal blood groups in maternal plasma samples critically depends on adequate amplification of fetal DNA. We evaluated the routine inclusion of 52 single-nucleotide polymorphisms (SNPs) as internal reference in our polymerase chain reaction (PCR) settings to obtain a positive internal control for fetal DNA. DNA from 223 plasma samples of pregnant women was screened for RHD Exons 3, 4, 5, and 7 in a multiplex PCR including 52 SNPs divided into four primer pools. Amplicons were analyzed by single-base extension and the GeneScan method in a genetic analyzer. Results of D screening were compared to standard RHD genotyping of amniotic fluid or real-time PCR of fetal DNA from maternal plasma. The vast majority of all samples (97.8%) demonstrated differences in maternal and fetal SNP patterns when tested with four primer pools. These differences were not observed in less than 2.2% of the samples most probably due to an extraction failure for adequate amounts of fetal DNA. Comparison of the fetal genotypes with independent results did not reveal a single false-negative case among samples (n = 42) with positive internal control and negative fetal RHD typing. Coamplification of 52 SNPs with RHD-specific sequences for fetal blood group determination introduces a valid positive control for the amplification of fetal DNA to avoid false-negative results. This new approach does not require a paternal blood sample. It may also be applicable to other assays for fetal genotyping in maternal blood samples. © 2012 American Association of Blood Banks.

  6. Affective valence influences participant's susceptibility to false memories and illusory recollection.

    PubMed

    Dehon, Hedwige; Larøi, Frank; Van der Linden, Martial

    2010-10-01

    This study examined the influence of emotional valence on the production of DRM false memories (Roediger & McDermott, 1995). Participants were presented with neutral, positive, or negative DRM lists for a later recognition (Experiment 1) or recall (Experiment 2) test. In both experiments, confidence and recollective experience (i.e., "Remember-Know" judgments; Tulving, 1985) were also assessed. Results consistently showed that, compared with neutral lists, affective lists induced more false recognition and recall of nonpresented critical lures. Moreover, although confidence ratings did not differ between the false remembering from the different kinds of lists, "Remember" responses were more often associated with negative than positive and neutral false remembering of the critical lures. In contrast, positive false remembering of the critical lures was more often associated with "Know" responses. These results are discussed in light of the Paradoxical Negative Emotion (PNE) hypothesis (Porter, Taylor, & ten Bricke, 2008). (PsycINFO Database Record (c) 2010 APA, all rights reserved).

  7. Hair Follicle Bulb as a Biodosimeter for Low-Level VX Vapor Exposure: Initial Studies Validating the Presence of Potential Protein Biomarkers of Exposure in the Sprague-Dawley Rat Whisker Follicle

    DTIC Science & Technology

    2006-10-01

    lead to false positive segmental hair analysis results.13 Due to the increased risk of false positives associated with segmental hair analysis ...to 200 mg of hair (to allow confirmation testing). 7 The segments are typically washed to remove external contaminants and the chemicals in the hair ...further confirmation. The method overcomes the false positives associated with traditional segmental hair analysis such. By measuring the

  8. Early Disseminated Lyme Disease Causing False-Positive Serology for Primary Epstein-Barr Virus Infection: Report of 2 Cases.

    PubMed

    Pavletic, Adriana J; Marques, Adriana R

    2017-07-15

    False-positive serology for Lyme disease was reported in patients with acute infectious mononucleosis. Here we describe 2 patients with early disseminated Lyme disease who were misdiagnosed with infectious mononucleosis based on false-positive tests for primary Epstein-Barr virus infection. Published by Oxford University Press for the Infectious Diseases Society of America 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  9. An approach to functionally relevant clustering of the protein universe: Active site profile‐based clustering of protein structures and sequences

    PubMed Central

    Knutson, Stacy T.; Westwood, Brian M.; Leuthaeuser, Janelle B.; Turner, Brandon E.; Nguyendac, Don; Shea, Gabrielle; Kumar, Kiran; Hayden, Julia D.; Harper, Angela F.; Brown, Shoshana D.; Morris, John H.; Ferrin, Thomas E.; Babbitt, Patricia C.

    2017-01-01

    Abstract Protein function identification remains a significant problem. Solving this problem at the molecular functional level would allow mechanistic determinant identification—amino acids that distinguish details between functional families within a superfamily. Active site profiling was developed to identify mechanistic determinants. DASP and DASP2 were developed as tools to search sequence databases using active site profiling. Here, TuLIP (Two‐Level Iterative clustering Process) is introduced as an iterative, divisive clustering process that utilizes active site profiling to separate structurally characterized superfamily members into functionally relevant clusters. Underlying TuLIP is the observation that functionally relevant families (curated by Structure‐Function Linkage Database, SFLD) self‐identify in DASP2 searches; clusters containing multiple functional families do not. Each TuLIP iteration produces candidate clusters, each evaluated to determine if it self‐identifies using DASP2. If so, it is deemed a functionally relevant group. Divisive clustering continues until each structure is either a functionally relevant group member or a singlet. TuLIP is validated on enolase and glutathione transferase structures, superfamilies well‐curated by SFLD. Correlation is strong; small numbers of structures prevent statistically significant analysis. TuLIP‐identified enolase clusters are used in DASP2 GenBank searches to identify sequences sharing functional site features. Analysis shows a true positive rate of 96%, false negative rate of 4%, and maximum false positive rate of 4%. F‐measure and performance analysis on the enolase search results and comparison to GEMMA and SCI‐PHY demonstrate that TuLIP avoids the over‐division problem of these methods. Mechanistic determinants for enolase families are evaluated and shown to correlate well with literature results. PMID:28054422

  10. An approach to functionally relevant clustering of the protein universe: Active site profile-based clustering of protein structures and sequences.

    PubMed

    Knutson, Stacy T; Westwood, Brian M; Leuthaeuser, Janelle B; Turner, Brandon E; Nguyendac, Don; Shea, Gabrielle; Kumar, Kiran; Hayden, Julia D; Harper, Angela F; Brown, Shoshana D; Morris, John H; Ferrin, Thomas E; Babbitt, Patricia C; Fetrow, Jacquelyn S

    2017-04-01

    Protein function identification remains a significant problem. Solving this problem at the molecular functional level would allow mechanistic determinant identification-amino acids that distinguish details between functional families within a superfamily. Active site profiling was developed to identify mechanistic determinants. DASP and DASP2 were developed as tools to search sequence databases using active site profiling. Here, TuLIP (Two-Level Iterative clustering Process) is introduced as an iterative, divisive clustering process that utilizes active site profiling to separate structurally characterized superfamily members into functionally relevant clusters. Underlying TuLIP is the observation that functionally relevant families (curated by Structure-Function Linkage Database, SFLD) self-identify in DASP2 searches; clusters containing multiple functional families do not. Each TuLIP iteration produces candidate clusters, each evaluated to determine if it self-identifies using DASP2. If so, it is deemed a functionally relevant group. Divisive clustering continues until each structure is either a functionally relevant group member or a singlet. TuLIP is validated on enolase and glutathione transferase structures, superfamilies well-curated by SFLD. Correlation is strong; small numbers of structures prevent statistically significant analysis. TuLIP-identified enolase clusters are used in DASP2 GenBank searches to identify sequences sharing functional site features. Analysis shows a true positive rate of 96%, false negative rate of 4%, and maximum false positive rate of 4%. F-measure and performance analysis on the enolase search results and comparison to GEMMA and SCI-PHY demonstrate that TuLIP avoids the over-division problem of these methods. Mechanistic determinants for enolase families are evaluated and shown to correlate well with literature results. © 2017 The Authors Protein Science published by Wiley Periodicals, Inc. on behalf of The Protein Society.

  11. The effect of sample storage on the performance and reproducibility of the galactomannan EIA test.

    PubMed

    Kimpton, George; White, P Lewis; Barnes, Rosemary A

    2014-08-01

    Galactomannan enzyme immune assay (GM EIA) is a nonculture test for detecting invasive aspergillosis (IA) forming a key part of diagnosis and management. Recent reports have questioned the reproducibility of indices after sample storage. To investigate this, 198 serum samples (72 from cases and 126 from controls) and 61 plasma samples (24 from cases and 37 from controls), initially tested between 2010 and 2013, were retested to determine any change in index. Data were also collected on circulatory protein levels for false-positive serum samples. Serum indices significantly declined on retesting (median: initial, 0.50, retest, 0.23; P < 0.0001). This was shown to be diagnosis dependent as the decline was apparent on retesting of control samples (median: initial 0.50, retest 0.12; P < 0.0001), but was not evident with case samples (median: initial, 0.80, retest, 0.80; P = 0.724). Plasma samples showed little change on reanalysis after long-term storage at 4°C. Retesting after freezing showed a decrease in index values for controls (median: initial 0.40, retest 0.26; P = 0.0505), but no significant change in cases. Circulatory proteins showed a correlation between serum albumin concentration and difference in index value on retesting. Overall, this study suggests that a lack of reproducibility in GM EIA positivity is only significant when disease is absent. Retesting after freezing helps to differentiate false-positive GM EIA results and, with consecutive positivity, could help to improve accuracy in predicting disease status. The freezing of samples prior to testing could potentially reduce false-positivity rates and the need to retest. © The Author 2014. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Acute hepatitis B virus infection with simultaneous high HBsAg and high anti-HBs signals in a previously HBV vaccinated HIV-1 positive patient.

    PubMed

    van Dommelen, Laura; Verbon, Annelies; van Doorn, H Rogier; Goossens, Valère J

    2010-03-01

    We present a case of a clinical manifest hepatitis B virus infection and a potentially misleading HBV serological profile in an HIV-1 positive patient despite previous HBV vaccination. The patient presented with an acute hepatitis B and there was no indication of chronic HBV infection or the presence of a mutation in the 'a' determinant. Remarkably, simultaneously with high HBV surface antigen and HBV viral load, high anti-HBs antibodies were present. If, due to previous HBV vaccination only anti-HBs was tested in this patient, the result of the high anti-HBs antibodies could be very misleading and offering a false sense of security. Our findings contribute to the ongoing discussion on how to assess HBV specific immunological memory and determining the role of HBV booster vaccinations in immunocompromised individuals.

  13. Clinical stage I carcinoma of the cervix. Value of MR imaging in determining invasion into the parametrium.

    PubMed

    Lien, H H; Blomlie, V; Iversen, T; Tropé, C; Sundfør, K; Abeler, V M

    1993-03-01

    Using MR imaging with a body coil parametrial invasion was determined prospectively in 169 consecutive patients considered on the basis of clinical examination to have carcinoma confined to the cervix. After radical hysterectomy correlation with histologic examination was performed for the left and right parametrium separately. The criterion for parametrial invasion was a high-signal-intensity lesion with disruption of the full thickness of the cervical stroma combined with areas of abnormal signal intensity within the parametrial region on T2-weighted images. Histologic examination showed that 18 parametria in 13 patients were invaded by tumor. MR had an overall accuracy of 93%, a sensitivity of 89%, and a specificity of 93% in demonstrating parametrial involvement. Positive and negative predictive values were 43% and 99%. The main weakness of MR was 21 false-positive tests. This represents a limitation when MR is performed with a body coil.

  14. Evaluating gold standard corpora against gene/protein tagging solutions and lexical resources

    PubMed Central

    2013-01-01

    Motivation The identification of protein and gene names (PGNs) from the scientific literature requires semantic resources: Terminological and lexical resources deliver the term candidates into PGN tagging solutions and the gold standard corpora (GSC) train them to identify term parameters and contextual features. Ideally all three resources, i.e. corpora, lexica and taggers, cover the same domain knowledge, and thus support identification of the same types of PGNs and cover all of them. Unfortunately, none of the three serves as a predominant standard and for this reason it is worth exploring, how these three resources comply with each other. We systematically compare different PGN taggers against publicly available corpora and analyze the impact of the included lexical resource in their performance. In particular, we determine the performance gains through false positive filtering, which contributes to the disambiguation of identified PGNs. Results In general, machine learning approaches (ML-Tag) for PGN tagging show higher F1-measure performance against the BioCreative-II and Jnlpba GSCs (exact matching), whereas the lexicon based approaches (LexTag) in combination with disambiguation methods show better results on FsuPrge and PennBio. The ML-Tag solutions balance precision and recall, whereas the LexTag solutions have different precision and recall profiles at the same F1-measure across all corpora. Higher recall is achieved with larger lexical resources, which also introduce more noise (false positive results). The ML-Tag solutions certainly perform best, if the test corpus is from the same GSC as the training corpus. As expected, the false negative errors characterize the test corpora and – on the other hand – the profiles of the false positive mistakes characterize the tagging solutions. Lex-Tag solutions that are based on a large terminological resource in combination with false positive filtering produce better results, which, in addition, provide concept identifiers from a knowledge source in contrast to ML-Tag solutions. Conclusion The standard ML-Tag solutions achieve high performance, but not across all corpora, and thus should be trained using several different corpora to reduce possible biases. The LexTag solutions have different profiles for their precision and recall performance, but with similar F1-measure. This result is surprising and suggests that they cover a portion of the most common naming standards, but cope differently with the term variability across the corpora. The false positive filtering applied to LexTag solutions does improve the results by increasing their precision without compromising significantly their recall. The harmonisation of the annotation schemes in combination with standardized lexical resources in the tagging solutions will enable their comparability and will pave the way for a shared standard. PMID:24112383

  15. Morphometric evaluation and nonclassical criteria for the diagnosis of HPV infection and cytological atypia in cervical samples.

    PubMed

    Sana, Dandara Emery Morais; Mayrink de Miranda, Priscila; Pitol, Bruna Caroline Vieira; Moran, Mariana Soares; Silva, Nayara Nascimento Toledo; Guerreiro da Silva, Ismael Dali Cotrim; de Cássia Stocco, Rita; Beçak, Willy; Lima, Angélica Alves; Carneiro, Cláudia Martins

    2013-09-01

    Herein, we evaluated cervical samples from normal tissue or HPV-infected tissue, to determine if the relative nuclear/cytoplasmic ratio (NA/CA) and the presence of nonclassical cytological criteria are a novel cytological criterion for the diagnosis of HPV. Significantly, larger NA/CA ratios were found for the HPV-ATYPIA+ and HPV+ATYPIA+ groups compared with HPV-ATYPIA- group, regardless of collection method. For the samples collected with a spatula, only three samples from the HPV-ATIPIA- group showed four or more nonclassical parameters (i.e., were positive), while a larger number of the samples in the HPV-ATYPIA+, HPV+ATYPIA-, and HPV+ATYPIA+ groups were positive (13, 4, and 13 samples, respectively). Among those collected with a brush, no sample showed four or more nonclassical criteria in the HPV-ATYPIA- group, while a number of samples were positive in the HPV-ATYPIA+, HPV+ATYPIA-, and HPV+ATYPIA+ groups (4, 3, and 4 samples, respectively). HPV infection was associated with significant morphometrical changes; no increase in the NA/CA ratio was found in the HPV+ATYPIA- samples, compared with the HPV-ATIPIA- samples collected with either a spatula or a brush. In conclusion, by including nonclassical cytological criteria into the patient diagnosis, we were able to reduce the number of false negative and false positive HPV diagnoses made using conventional cytology alone. Copyright © 2013 Wiley Periodicals, Inc.

  16. Positive events protect children from causal false memories for scripted events.

    PubMed

    Melinder, Annika; Toffalini, Enrico; Geccherle, Eleonora; Cornoldi, Cesare

    2017-11-01

    Adults produce fewer inferential false memories for scripted events when their conclusions are emotionally charged than when they are neutral, but it is not clear whether the same effect is also found in children. In the present study, we examined this issue in a sample of 132 children aged 6-12 years (mean 9 years, 3 months). Participants encoded photographs depicting six script-like events that had a positively, negatively, or a neutral valenced ending. Subsequently, true and false recognition memory of photographs related to the observed scripts was tested as a function of emotionality. Causal errors-a type of false memory thought to stem from inferential processes-were found to be affected by valence: children made fewer causal errors for positive than for neutral or negative events. Hypotheses are proposed on why adults were found protected against inferential false memories not only by positive (as for children) but also by negative endings when administered similar versions of the same paradigm.

  17. Feline focus: Diagnostic testing for feline thyroid disease: hyperthyroidism.

    PubMed

    Peterson, Mark E

    2013-08-01

    In older cats presenting with clinical features of hyperthyroidism, confirming the diagnosis of thyroid disease is usually straightforward. However, the potential for false-negative and false-positive results exists with all thyroid function tests, especially when used for routine screening of large numbers of asymptomatic cats. Therefore, all thyroid function test results must be interpreted in light of the cat's history, clinical signs, and other laboratory findings. If a high serum thyroxine (T4) value is found in a cat that lacks clinical signs of hyperthyroidism, or if hyperthyroidism is suspected in a cat with normal total T4 concentrations, repeating the total T4 analysis, determining the free T4 concentration, or performing thyroid scintigraphy may be needed to confirm the diagnosis.

  18. Quality of malaria diagnosis and molecular confirmation of Plasmodium ovale curtisi in a rural area of the southeastern region of Ethiopia.

    PubMed

    Díaz, Pedro Berzosa; Lozano, Patricia Mula; Rincón, Jose Manuel Ramos; García, Luz; Reyes, Francisco; Llanes, Agustín Benito

    2015-09-18

    Approximately 50 million people (60 %) live in malaria risk areas in Ethiopia, at altitudes below 2000 m. According to official data, 60-70 % of malaria cases are due to Plasmodium falciparum, and 40-30 % by Plasmodium vivax. The species Plasmodium ovale was detected in 2013 in the northwest of the country, being the first report of the presence of this species in Ethiopia since the 60 s. The aim of this study was to assess the diagnosis by microscopy and PCR, and demonstrate the presence of other Plasmodium species in the country. The survey was conducted in Bulbula, situated in the Rift Valley (West Arsi Province, Oromia Region). From December 2010 to October 2011, 3060 samples were collected from patients with symptoms of malaria; the diagnosis of malaria was done by microscopy and confirmation by PCR. 736 samples were positive for malaria by microscopy. After removing the 260 samples (109 positives and 151 negatives) for which it was not possible to do PCR, there were a total of 2800 samples, 1209 are used for its confirmation by PCR and quality control (627 are positives and 582 negatives by microscopy). From the 627 positive samples, 604 were confirmed as positive by PCR, 23 false positives were detected, and the group of 582 negative samples, 184 were positive by PCR (false negatives), which added to the previous positive samples is a total of 788, positive samples for some species of Plasmodium sp. 13.3 % more positives were detected with the PCR than the microscopy. Importantly, 23 samples were detected by PCR as P. ovale, after the sequencing of these samples was determined as P. ovale curtisi. The PCR detected more positive samples than the microscopy; in addition, P. ovale and P. ovale/P. vivax were detected that had not been detected by microscopy, which can affect in the infection control.

  19. Evidence-based guideline update: determining brain death in adults: report of the Quality Standards Subcommittee of the American Academy of Neurology.

    PubMed

    Wijdicks, Eelco F M; Varelas, Panayiotis N; Gronseth, Gary S; Greer, David M

    2010-06-08

    To provide an update of the 1995 American Academy of Neurology guideline with regard to the following questions: Are there patients who fulfill the clinical criteria of brain death who recover neurologic function? What is an adequate observation period to ensure that cessation of neurologic function is permanent? Are complex motor movements that falsely suggest retained brain function sometimes observed in brain death? What is the comparative safety of techniques for determining apnea? Are there new ancillary tests that accurately identify patients with brain death? A systematic literature search was conducted and included a review of MEDLINE and EMBASE from January 1996 to May 2009. Studies were limited to adults. In adults, there are no published reports of recovery of neurologic function after a diagnosis of brain death using the criteria reviewed in the 1995 American Academy of Neurology practice parameter. Complex-spontaneous motor movements and false-positive triggering of the ventilator may occur in patients who are brain dead. There is insufficient evidence to determine the minimally acceptable observation period to ensure that neurologic functions have ceased irreversibly. Apneic oxygenation diffusion to determine apnea is safe, but there is insufficient evidence to determine the comparative safety of techniques used for apnea testing. There is insufficient evidence to determine if newer ancillary tests accurately confirm the cessation of function of the entire brain.

  20. Fuzzy logic-based approach to detecting a passive RFID tag in an outpatient clinic.

    PubMed

    Min, Daiki; Yih, Yuehwern

    2011-06-01

    This study is motivated by the observations on the data collected by radio frequency identification (RFID) readers in a pilot study, which was used to investigate the feasibility of implementing an RFID-based monitoring system in an outpatient eye clinic. The raw RFID data collected from RFID readers contain noise and missing reads, which prevent us from determining the tag location. In this paper, fuzzy logic-based algorithms are proposed to interpret the raw RFID data to extract accurate information. The proposed algorithms determine the location of an RFID tag by evaluating its possibility of presence and absence. To evaluate the performance of the proposed algorithms, numerical experiments are conducted using the data observed in the outpatient eye clinic. Experiments results showed that the proposed algorithms outperform existing static smoothing method in terms of minimizing both false positives and false negatives. Furthermore, the proposed algorithms are applied to a set of simulated data to show the robustness of the proposed algorithms at various levels of RFID reader reliability.

  1. Human antibodies to bovine alpha-globulin.

    PubMed

    Foucard, T; Bennich, H; Johansson, S G; Lundkvist, U

    1975-01-01

    Antibodies to bovine gamma-globulin (anti-BGG antibodies) were detectable by a radio-immunoassay in 70% of healthy blood donors but, generally, the titres were low. Significantly increased concentrations of anti-BGG antibodies were found in patients lacking IgA but not in patients with allergic disorders. The anti-BGG antibodies were shown to give rise to falsely high IgE values in the radio-immunosorbent test for IgE determination (RIST) when a sheep anti-IgE antiserum was used. Furthermore, falsely positive results can sometimes be caused by such antibodies in the determination of cow-dander- or cow's-milk-specific IgE by the radio-allergosorbent test (RAST). When a rabbit anti-IgE antiserum was used instead of the sheep anti-IgE, normal IgE levels and negative RAST results were obtained. The difference is explained by the higher degree of cross-reactivity between the anti-BGG antibodies and sheep alpha-globulin than between anti-BGG antibodies and rabbit alpha-globulin.

  2. Probabilistic Tractography of the Cranial Nerves in Vestibular Schwannoma.

    PubMed

    Zolal, Amir; Juratli, Tareq A; Podlesek, Dino; Rieger, Bernhard; Kitzler, Hagen H; Linn, Jennifer; Schackert, Gabriele; Sobottka, Stephan B

    2017-11-01

    Multiple recent studies have reported on diffusion tensor-based fiber tracking of cranial nerves in vestibular schwannoma, with conflicting results as to the accuracy of the method and the occurrence of cochlear nerve depiction. Probabilistic nontensor-based tractography might offer advantages in terms of better extraction of directional information from the underlying data in cranial nerves, which are of subvoxel size. Twenty-one patients with large vestibular schwannomas were recruited. The probabilistic tracking was run preoperatively and the position of the potential depictions of the facial and cochlear nerves was estimated postoperatively by 3 independent observers in a blinded fashion. The true position of the nerve was determined intraoperatively by the surgeon. Thereafter, the imaging-based estimated position was compared with the intraoperatively determined position. Tumor size, cystic appearance, and postoperative House-Brackmann score were analyzed with regard to the accuracy of the depiction of the nerves. The probabilistic tracking showed a connection that correlated to the position of the facial nerve in 81% of the cases and to the position of the cochlear nerve in 33% of the cases. Altogether, the resulting depiction did not correspond to the intraoperative position of any of the nerves in 3 cases. In a majority of cases, the position of the facial nerve, but not of the cochlear nerve, could be estimated by evaluation of the probabilistic tracking results. However, false depictions not corresponding to any nerve do occur and cannot be discerned as such from the image only. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Minimizing false positive error with multiple performance validity tests: response to Bilder, Sugar, and Hellemann (2014 this issue).

    PubMed

    Larrabee, Glenn J

    2014-01-01

    Bilder, Sugar, and Hellemann (2014 this issue) contend that empirical support is lacking for use of multiple performance validity tests (PVTs) in evaluation of the individual case, differing from the conclusions of Davis and Millis (2014), and Larrabee (2014), who found no substantial increase in false positive rates using a criterion of failure of ≥ 2 PVTs and/or Symptom Validity Tests (SVTs) out of multiple tests administered. Reconsideration of data presented in Larrabee (2014) supports a criterion of ≥ 2 out of up to 7 PVTs/SVTs, as keeping false positive rates close to and in most cases below 10% in cases with bona fide neurologic, psychiatric, and developmental disorders. Strategies to minimize risk of false positive error are discussed, including (1) adjusting individual PVT cutoffs or criterion for number of PVTs failed, for examinees who have clinical histories placing them at risk for false positive identification (e.g., severe TBI, schizophrenia), (2) using the history of the individual case to rule out conditions known to result in false positive errors, (3) using normal performance in domains mimicked by PVTs to show that sufficient native ability exists for valid performance on the PVT(s) that have been failed, and (4) recognizing that as the number of PVTs/SVTs failed increases, the likelihood of valid clinical presentation decreases, with a corresponding increase in the likelihood of invalid test performance and symptom report.

  4. An Evaluation of Unit and ½ Mass Correction Approaches as a ...

    EPA Pesticide Factsheets

    Rare earth elements (REE) and certain alkaline earths can produce M+2 interferences in ICP-MS because they have sufficiently low second ionization energies. Four REEs (150Sm, 150Nd, 156Gd and 156Dy) produce false positives on 75As and 78Se and 132Ba can produce a false positive on 66Zn. Currently, US EPA Method 200.8 does not address these as sources of false positives. Additionally, these M+2 false positives are typically enhanced if collision cell technology is utilized to reduce polyatomic interferences associated with ICP-MS detection. A preliminary evaluation indicates that instrumental tuning conditions can impact the observed M+2/M+1 ratio and in turn the false positives generated on Zn, As and Se. Both unit and ½ mass approaches will be evaluated to correct for these false positives relative to the benchmark concentrations estimates from a triple quadrupole ICP-MS using standard solutions. The impact of matrix on these M+2 corrections will be evaluated over multiple analysis days with a focus on evaluating internal standards that mirror the matrix induced shifts in the M+2 ion transmission. The goal of this evaluation is to move away from fixed M+2 corrective approaches and move towards sample specific approaches that mimic the sample matrix induced variability while attempting to address intra-day variability of the M+2 correction factors through the use of internal standards. Oral Presentation via webinar for EPA Laboratory Technical Informati

  5. [Feline leukemia virus infection: importance and current situation in Switzerland].

    PubMed

    Hofmann-Lehmann, R; Gönczi, E; Riond, B; Meli, M; Willi, B; Howard, J; Schaarschmidt-Kiener, D; Regli, W; Gilli, U; Boretti, F

    2018-02-01

    Feline leukemia virus (FeLV) leads to fatal disease in cats with progressive infection. The aim of this study was to determine the importance of FeLV infection in Switzerland and make a comparison with previous studies. Of 881 blood samples taken from cats living in Switzerland (minimum of 20 samples per Canton), 47 samples were provirus-positive (5.3%; 95% confidence interval (CI) 3.9-7.0%) and 18 samples were antigen-positive (2%; 95% CI 1.2-3.2%). Together with data previously collected in similar studies, these findings demonstrated a decrease in prevalence between 1997 and 2003 followed by a relative constant low prevalence thereafter. Young cats (=2 years) were more frequently infected than older cats, but FeLV-positive cats were up to 15 (antigen-positive) and 19 (provirus-positive) years old. Sexually intact cats were more frequently viremic than neutered cats; purebred cats were somewhat less frequently FeLV-positive than non-purebred cats. In a second study, in which 300 saliva samples were analyzed, samples from 5 cats were FeLV-RNA positive (1.7%; 95% CI, 0.5-3.8%), although one young feral cat had been falsely assumed to be FeLV-negative based on a point-of-care test. Of the 300 cats, only 50% were FeLV tested or vaccinated, although 90% of the cats were at risk of exposure to FeLV. Testing and vaccination of all cats with exposure risk may help further decrease the prevalence of FeLV infection. Moreover, characteristics of FeLV tests should be considered, such as the risk of false negative results in the early phase of infection when performing antigen testing.

  6. Use of the Abbott Architect HIV antigen/antibody assay in a low incidence population.

    PubMed

    Dubravac, Terry; Gahan, Thomas F; Pentella, Michael A

    2013-12-01

    With the availability of 4th generation HIV diagnostic tests which are capable of detecting acute infection, Iowa evaluated the 3rd and 4th generation HIV test and compared the performance of these products in a low incidence population. This study was conducted to evaluate the performance of an HIV antigen/antibody combination (4th generation) assay compared to an EIA 3rd generation assay. Over a 4 month period, 2037 specimens submitted for HIV screening were tested by Bio-Rad GS HIV-1/HIV-2 Plus O EIA and the Abbott Architect i1000SR HIV Ag/Ab Combo. The performance characteristics of sensitivity, specificity, positive predictive value and negative predictive value were determined. Of the 2037 specimens tested, there were 13 (0.64%) true positives detected. None of the positive specimens were from patients in the acute phase of infection. The Abbott antigen/antibody combo assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.85%, 81.25%, and 100% respectively. The Bio-Rad EIA assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.80%, 76.47% and 100%, respectively. The EIA had four false positive results which tested negative by the antigen/antibody assay and western blot. In a low-incidence state where early infections are less commonly encountered, the EIA assay and the antigen/antibody assay performed with near equivalency. The antigen/antibody assay had one less false positive result. While no patients were detected in the acute stage of infection, the use of the antigen/antibody assay presents the opportunity to detect an infected patient sooner and prevent transmission to others. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Extended focused assessment with sonography for trauma (EFAST) in the diagnosis of pneumothorax: experience at a community based level I trauma center.

    PubMed

    Nandipati, Kalyana C; Allamaneni, Shyam; Kakarla, Ravindra; Wong, Alfredo; Richards, Neil; Satterfield, James; Turner, James W; Sung, Kae-Jae

    2011-05-01

    Early identification of pneumothorax is crucial to reduce the mortality in critically injured patients. The objective of our study is to investigate the utility of surgeon performed extended focused assessment with sonography for trauma (EFAST) in the diagnosis of pneumothorax. We prospectively analysed 204 trauma patients in our level I trauma center over a period of 12 (06/2007-05/2008) months in whom EFAST was performed. The patients' demographics, type of injury, clinical examination findings (decreased air entry), CXR, EFAST and CT scan findings were entered into the data base. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated. Of 204 patients (mean age--43.01+/-19.5 years, sex--male 152, female 52) 21 (10.3%) patients had pneumothorax. Of 21 patients who had pneumothorax 12 were due to blunt trauma and 9 were due to penetrating trauma. The diagnosis of pneumothorax in 204 patients demonstrated the following: clinical examination was positive in 17 patients (true positive in 13/21, 62%; 4 were false positive and 8 were false negative), CXR was positive in 16 (true positive in 15/19, 79%; 1 false positive, 4 missed and 2 CXR not performed before chest tube) patients and EFAST was positive in 21 patients (20 were true positive [95.2%], 1 false positive and 1 false negative). In diagnosing pneumothorax EFAST has significantly higher sensitivity compared to the CXR (P=0.02). Surgeon performed trauma room extended FAST is simple and has higher sensitivity compared to the chest X-ray and clinical examination in detecting pneumothorax. Published by Elsevier Ltd.

  8. When good news is bad news: psychological impact of false positive diagnosis of HIV.

    PubMed

    Bhattacharya, Rahul; Barton, Simon; Catalan, Jose

    2008-05-01

    HIV testing is known to be stressful, however the impact of false positive HIV results on individuals is not well documented. This is a series of four case who developed psychological difficulties and psychiatric morbidities after being informed they had been misdiagnosed with HIV-positive status. We look into documented cases of misdiagnosis and potential risks of misdiagnosis. The case series highlights the implications a false diagnosis HIV-positive status can have, even when the diagnosis is rectified. Impact of misdiagnosis of HIV can lead to psychosocial difficulties and psychiatric morbidity, have public health and epidemiological implications and can lead to medico-legal conflict. This further reiterates the importance of HIV testing carried out ethically and sensitively, and in line with guidelines, respecting confidentiality and consent, and offering counselling pre-test and post-test, being mindful of the reality of erroneous and false positive HIV test results. The implications of misdiagnosis are for the individual, their partners and social contacts, as well as for the community.

  9. False-positive iodine-131 whole-body scan findings in patients with differentiated thyroid carcinoma: report of 11 cases and review of the literature.

    PubMed

    Buton, Leckzinscka; Morel, Olivier; Gault, Patricia; Illouz, Frédéric; Rodien, Patrice; Rohmer, Vincent

    2013-07-01

    Iodine-131 (I-131) whole-body scan (WBS) plays an important role in the management of patients with differentiated thyroid carcinoma (DTC), to detect normal thyroid remnants and recurrent or metastatic disease. A focus of I-131 accumulation outside the thyroid bed and the areas of physiological uptake is strongly suggestive of a distant functioning metastasis. However, many false-positive I-131 WBS findings have been reported in the literature. We describe a series of 11 personal cases of patients with DTC, collected from 1992 to 2011, in whom diagnostic or post-treatment WBS showed false-positive retention of I-131 in various locations. False-positive accumulations of I-131 on WBS may be classified according to the underlying pathophysiological mechanisms: external and internal contaminations by body secretions, ectopic normal thyroid and gastric tissues, inflammatory and infectious diseases, benign and malignant tumors, cysts and effusions of serous cavities, thymic uptake, and other non classified causes. Clinicians must be aware of possible false-positive findings to avoid misinterpretations of the I-131 WBS, which could lead to inappropriate treatments. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  10. Comparing diagnostic tests on benefit-risk.

    PubMed

    Pennello, Gene; Pantoja-Galicia, Norberto; Evans, Scott

    2016-01-01

    Comparing diagnostic tests on accuracy alone can be inconclusive. For example, a test may have better sensitivity than another test yet worse specificity. Comparing tests on benefit risk may be more conclusive because clinical consequences of diagnostic error are considered. For benefit-risk evaluation, we propose diagnostic yield, the expected distribution of subjects with true positive, false positive, true negative, and false negative test results in a hypothetical population. We construct a table of diagnostic yield that includes the number of false positive subjects experiencing adverse consequences from unnecessary work-up. We then develop a decision theory for evaluating tests. The theory provides additional interpretation to quantities in the diagnostic yield table. It also indicates that the expected utility of a test relative to a perfect test is a weighted accuracy measure, the average of sensitivity and specificity weighted for prevalence and relative importance of false positive and false negative testing errors, also interpretable as the cost-benefit ratio of treating non-diseased and diseased subjects. We propose plots of diagnostic yield, weighted accuracy, and relative net benefit of tests as functions of prevalence or cost-benefit ratio. Concepts are illustrated with hypothetical screening tests for colorectal cancer with test positive subjects being referred to colonoscopy.

  11. Gas insufflation of minimal preparation CT of the colon reduces false-positives

    PubMed Central

    Slater, A; North, M; Hart, M; Ferrett, C

    2012-01-01

    Objectives Minimal preparation CT of the colon (MPCT colon) is used for investigation of suspected colorectal cancer in frail and/or elderly patients who would be expected to tolerate laxative bowel preparation poorly. Although it has good sensitivity for colorectal cancer it has a poor specificity. We wished to investigate whether distension of the colon with carbon dioxide alone would reduce the number of false-positives, but without making the test arduous or excessively uncomfortable. Methods 134 patients were recruited and underwent MPCT colon with gas insufflation and antispasmodics. Results were compared with a cohort of 134 patients undergoing standard protocol MPCT colon. The numbers of false-positives were compared, as was reader confidence. All trial patients were given a questionnaire documenting their experience. Results The number of false-positives was 15% in the control group and 5% in the trial group; this difference was statistically significant, (p=0.01). Reader confidence was increased in the trial group. Patient tolerance was good, with 95% saying they would have the test again. Conclusion Use of gas insufflation and antispasmodics reduces the false-positives from 15% to 5% without adversely affecting patient tolerance. PMID:21224295

  12. A cluster of culture positive gonococcal infections but with false negative cppB gene based PCR.

    PubMed

    Lum, G; Freeman, K; Nguyen, N L; Limnios, E A; Tabrizi, S N; Carter, I; Chambers, I W; Whiley, D M; Sloots, T P; Garland, S M; Tapsall, J W

    2005-10-01

    To describe the prevalence and characteristics of isolates of Neisseria gonorrhoeae grown from urine samples that produced negative results with nucleic acid amplification assays (NAA) targeting the cppB gene. An initial cluster of culture positive, but cppB gene based NAA negative, gonococcal infections was recognised. Urine samples and suspensions of gonococci isolated over 9 months in the Northern Territory of Australia were examined using cppB gene based and other non-cppB gene based NAA. The gonococcal isolates were phenotyped by determining the auxotype/serovar (A/S) class and genotyped by pulsed field gel electrophoresis (PFGE). 14 (9.8%) of 143 gonococci isolated were of A/S class Pro(-/)Brpyut, indistinguishable on PFGE and negative in cppB gene based, but not other, NAA. This cluster represents a temporal and geographic expansion of a gonococcal subtype lacking the cppB gene with consequent loss of sensitivity of NAA dependent on amplification of this target. Gonococci lacking the cppB gene have in the past been more commonly associated with the PAU-/PCU- auxotype, a gonococcal subtype hitherto infrequently encountered in Australia. NAA based on the cppB gene as a target may produce false positive as well as false negative NAA. This suggests that unless there is continuing comparison with culture to show their utility, cppB gene based NAA should be regarded as suboptimal for use either as a diagnostic or supplemental assay for diagnosis of gonorrhoea, and NAA with alternative amplification targets should be substituted.

  13. Convolutional neural network based deep-learning architecture for prostate cancer detection on multiparametric magnetic resonance images

    NASA Astrophysics Data System (ADS)

    Tsehay, Yohannes K.; Lay, Nathan S.; Roth, Holger R.; Wang, Xiaosong; Kwak, Jin Tae; Turkbey, Baris I.; Pinto, Peter A.; Wood, Brad J.; Summers, Ronald M.

    2017-03-01

    Prostate cancer (PCa) is the second most common cause of cancer related deaths in men. Multiparametric MRI (mpMRI) is the most accurate imaging method for PCa detection; however, it requires the expertise of experienced radiologists leading to inconsistency across readers of varying experience. To increase inter-reader agreement and sensitivity, we developed a computer-aided detection (CAD) system that can automatically detect lesions on mpMRI that readers can use as a reference. We investigated a convolutional neural network based deep-learing (DCNN) architecture to find an improved solution for PCa detection on mpMRI. We adopted a network architecture from a state-of-the-art edge detector that takes an image as an input and produces an image probability map. Two-fold cross validation along with a receiver operating characteristic (ROC) analysis and free-response ROC (FROC) were used to determine our deep-learning based prostate-CAD's (CADDL) performance. The efficacy was compared to an existing prostate CAD system that is based on hand-crafted features, which was evaluated on the same test-set. CADDL had an 86% detection rate at 20% false-positive rate while the top-down learning CAD had 80% detection rate at the same false-positive rate, which translated to 94% and 85% detection rate at 10 false-positives per patient on the FROC. A CNN based CAD is able to detect cancerous lesions on mpMRI of the prostate with results comparable to an existing prostate-CAD showing potential for further development.

  14. Computational investigation of kinetics of cross-linking reactions in proteins: importance in structure prediction.

    PubMed

    Bandyopadhyay, Pradipta; Kuntz, Irwin D

    2009-01-01

    The determination of protein structure using distance constraints is a new and promising field of study. One implementation involves attaching residues of a protein using a cross-linking agent, followed by protease digestion, analysis of the resulting peptides by mass spectroscopy, and finally sequence threading to detect the protein folds. In the present work, we carry out computational modeling of the kinetics of cross-linking reactions in proteins using the master equation approach. The rate constants of the cross-linking reactions are estimated using the pKas and the solvent-accessible surface areas of the residues involved. This model is tested with fibroblast growth factor (FGF) and cytochrome C. It is consistent with the initial experimental rate data for individual lysine residues for cytochrome C. Our model captures all observed cross-links for FGF and almost 90% of the observed cross-links for cytochrome C, although it also predicts cross-links that were not observed experimentally (false positives). However, the analysis of the false positive results is complicated by the fact that experimental detection of cross-links can be difficult and may depend on specific experimental conditions such as pH, ionic strength. Receiver operator characteristic plots showed that our model does a good job in predicting the observed cross-links. Molecular dynamics simulations showed that for cytochrome C, in general, the two lysines come closer for the observed cross-links as compared to the false positive ones. For FGF, no such clear pattern exists. The kinetic model and MD simulation can be used to study proposed cross-linking protocols.

  15. Sensitivity and specificity of a two-question screening tool for depression in a specialist palliative care unit.

    PubMed

    Payne, Ann; Barry, Sandra; Creedon, Brian; Stone, Carol; Sweeney, Catherine; O' Brien, Tony; O' Sullivan, Kathleen

    2007-04-01

    The primary objective in this study is to determine the sensitivity and specificity of a two-item screening interview for depression versus the formal psychiatric interview, in the setting of a specialist palliative in-patient unit so that we may identify those individuals suffering from depressive disorder and therefore optimise their management in this often-complex population. A prospective sample of consecutive admissions (n = 167) consented to partake in the study, and the screening interview was asked separately to the formal psychiatric interview. The two-item questionnaire, achieved a sensitivity of 90.7% (95% CI 76.9-97.0) but a lower specificity of 67.7% (95% CI 58.7-75.7). The false positive rate was 32.3% (95% CI 24.3-41.3), but the false negative rate was found to be a low 9.3% (95% CI 3.0-23.1). A subgroup analysis of individuals with a past experience of depressive illness, (n = 95), revealed that a significant number screened positive for depression by the screening test, 55.2% (16/29) compared to those with no background history of depression, 33.3% (22/66) (P = 0.045). The high sensitivity and low false negative rate of the two-question screening tool will aid health professionals in identifying depression in the in-patient specialist palliative care unit. Individuals, who admit to a previous experience of depressive illness, are more likely to respond positively to the two-item questionnaire than those who report no prior history of depressive illness (P = 0.045).

  16. Predicting abuse potential of stimulants and other dopaminergic drugs: overview and recommendations.

    PubMed

    Huskinson, Sally L; Naylor, Jennifer E; Rowlett, James K; Freeman, Kevin B

    2014-12-01

    Examination of a drug's abuse potential at multiple levels of analysis (molecular/cellular action, whole-organism behavior, epidemiological data) is an essential component to regulating controlled substances under the Controlled Substances Act (CSA). We reviewed studies that examined several central nervous system (CNS) stimulants, focusing on those with primarily dopaminergic actions, in drug self-administration, drug discrimination, and physical dependence. For drug self-administration and drug discrimination, we distinguished between experiments conducted with rats and nonhuman primates (NHP) to highlight the common and unique attributes of each model in the assessment of abuse potential. Our review of drug self-administration studies suggests that this procedure is important in predicting abuse potential of dopaminergic compounds, but there were many false positives. We recommended that tests to determine how reinforcing a drug is relative to a known drug of abuse may be more predictive of abuse potential than tests that yield a binary, yes-or-no classification. Several false positives also occurred with drug discrimination. With this procedure, we recommended that future research follow a standard decision-tree approach that may require examining the drug being tested for abuse potential as the training stimulus. This approach would also allow several known drugs of abuse to be tested for substitution, and this may reduce false positives. Finally, we reviewed evidence of physical dependence with stimulants and discussed the feasibility of modeling these phenomena in nonhuman animals in a rational and practical fashion. This article is part of the Special Issue entitled 'CNS Stimulants'. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Validating a strategy for psychosocial phenotyping using a large corpus of clinical text.

    PubMed

    Gundlapalli, Adi V; Redd, Andrew; Carter, Marjorie; Divita, Guy; Shen, Shuying; Palmer, Miland; Samore, Matthew H

    2013-12-01

    To develop algorithms to improve efficiency of patient phenotyping using natural language processing (NLP) on text data. Of a large number of note titles available in our database, we sought to determine those with highest yield and precision for psychosocial concepts. From a database of over 1 billion documents from US Department of Veterans Affairs medical facilities, a random sample of 1500 documents from each of 218 enterprise note titles were chosen. Psychosocial concepts were extracted using a UIMA-AS-based NLP pipeline (v3NLP), using a lexicon of relevant concepts with negation and template format annotators. Human reviewers evaluated a subset of documents for false positives and sensitivity. High-yield documents were identified by hit rate and precision. Reasons for false positivity were characterized. A total of 58 707 psychosocial concepts were identified from 316 355 documents for an overall hit rate of 0.2 concepts per document (median 0.1, range 1.6-0). Of 6031 concepts reviewed from a high-yield set of note titles, the overall precision for all concept categories was 80%, with variability among note titles and concept categories. Reasons for false positivity included templating, negation, context, and alternate meaning of words. The sensitivity of the NLP system was noted to be 49% (95% CI 43% to 55%). Phenotyping using NLP need not involve the entire document corpus. Our methods offer a generalizable strategy for scaling NLP pipelines to large free text corpora with complex linguistic annotations in attempts to identify patients of a certain phenotype.

  18. Validating a strategy for psychosocial phenotyping using a large corpus of clinical text

    PubMed Central

    Gundlapalli, Adi V; Redd, Andrew; Carter, Marjorie; Divita, Guy; Shen, Shuying; Palmer, Miland; Samore, Matthew H

    2013-01-01

    Objective To develop algorithms to improve efficiency of patient phenotyping using natural language processing (NLP) on text data. Of a large number of note titles available in our database, we sought to determine those with highest yield and precision for psychosocial concepts. Materials and methods From a database of over 1 billion documents from US Department of Veterans Affairs medical facilities, a random sample of 1500 documents from each of 218 enterprise note titles were chosen. Psychosocial concepts were extracted using a UIMA-AS-based NLP pipeline (v3NLP), using a lexicon of relevant concepts with negation and template format annotators. Human reviewers evaluated a subset of documents for false positives and sensitivity. High-yield documents were identified by hit rate and precision. Reasons for false positivity were characterized. Results A total of 58 707 psychosocial concepts were identified from 316 355 documents for an overall hit rate of 0.2 concepts per document (median 0.1, range 1.6–0). Of 6031 concepts reviewed from a high-yield set of note titles, the overall precision for all concept categories was 80%, with variability among note titles and concept categories. Reasons for false positivity included templating, negation, context, and alternate meaning of words. The sensitivity of the NLP system was noted to be 49% (95% CI 43% to 55%). Conclusions Phenotyping using NLP need not involve the entire document corpus. Our methods offer a generalizable strategy for scaling NLP pipelines to large free text corpora with complex linguistic annotations in attempts to identify patients of a certain phenotype. PMID:24169276

  19. Rediscovery rate estimation for assessing the validation of significant findings in high-throughput studies.

    PubMed

    Ganna, Andrea; Lee, Donghwan; Ingelsson, Erik; Pawitan, Yudi

    2015-07-01

    It is common and advised practice in biomedical research to validate experimental or observational findings in a population different from the one where the findings were initially assessed. This practice increases the generalizability of the results and decreases the likelihood of reporting false-positive findings. Validation becomes critical when dealing with high-throughput experiments, where the large number of tests increases the chance to observe false-positive results. In this article, we review common approaches to determine statistical thresholds for validation and describe the factors influencing the proportion of significant findings from a 'training' sample that are replicated in a 'validation' sample. We refer to this proportion as rediscovery rate (RDR). In high-throughput studies, the RDR is a function of false-positive rate and power in both the training and validation samples. We illustrate the application of the RDR using simulated data and real data examples from metabolomics experiments. We further describe an online tool to calculate the RDR using t-statistics. We foresee two main applications. First, if the validation study has not yet been collected, the RDR can be used to decide the optimal combination between the proportion of findings taken to validation and the size of the validation study. Secondly, if a validation study has already been done, the RDR estimated using the training data can be compared with the observed RDR from the validation data; hence, the success of the validation study can be assessed. © The Author 2014. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  20. False memories, but not false beliefs, affect implicit attitudes for food preferences.

    PubMed

    Howe, David; Anderson, Rachel J; Dewhurst, Stephen A

    2017-09-01

    Previous studies have found that false memories and false beliefs of childhood experiences can have attitudinal consequences. Previous studies have, however, focused exclusively on explicit attitude measures without exploring whether implicit attitudes are similarly affected. Using a false feedback/imagination inflation paradigm, false memories and beliefs of enjoying a certain food as a child were elicited in participants, and their effects were assessed using both explicit attitude measures (self-report questionnaires) and implicit measures (a Single-Target Implicit Association Test). Positive changes in explicit attitudes were observed both in participants with false memories and participants with false beliefs. In contrast, only participants with false memories exhibited more positive implicit attitudes. The findings are discussed in terms of theories of explicit and implicit attitudes. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Prevalence of Brucella abortus antibodies in equines of a tropical region of Mexico

    PubMed Central

    Acosta-González, Rosa I.; González-Reyes, Ismael; Flores-Gutiérrez, Gerardo H.

    2006-01-01

    A cross-sectional study was conducted to determinate the seroprevalence rate of equine brucellosis in the state of Tamaulipas, Mexico. Serum samples from 420 equines were analyzed with the Rose Bengal test at cell concentrations of 3% (RBT-3%) and 8% (RBT-8%), and positive results were confirmed with the Rivanol test (RT). Risk factors were determined with the prevalence ratio (PR) and the use of variables generated from a questionnaire administered to the animals’ owners. Serum from 1 stallion had positive results with both the RBT-8% and the RT, for a seroprevalence rate of 0.238%. Drinking of water from a pond that was also used by cattle and dogs was the only associated risk factor for this animal (PR = 0.25). However, the results were considered false-positive, because the results for other horses in the same environmental conditions were negative. Although brucellosis is considered endemic in ruminants in the study area, the results obtained suggest that equines are not a reservoir of brucellosis and do not play an important role in the epidemiologic patterns of this disease in northeastern Mexico. PMID:17042384

  2. Identifying seizure clusters in patients with epilepsy

    PubMed Central

    Lipton, R. B.; LeValley, A. J.; Hall, C. B.; Shinnar, S.

    2006-01-01

    Clinicians often encounter patients whose neurologic attacks appear to cluster. In a daily diary study, the authors explored whether clustering is a true phenomenon in epilepsy and can be identified in the clinical setting. Nearly half the subjects experienced at least one episode of three or more seizures in 24 hours; 20% also met a statistical clustering criterion. Utilizing the clinical definition of clustering should identify all seizure clusterers, and false positives can be determined with diary data. PMID:16247068

  3. Assessment of potential false positives via orbitrap-based untargeted lipidomics from rat tissues.

    PubMed

    Xu, Lina; Wang, Xueying; Jiao, Yupei; Liu, Xiaohui

    2018-02-01

    Untargeted lipidomics is increasingly popular due to the broad coverage of lipid species. Data dependent MS/MS acquisition is commonly used in order to acquire sufficient information for confident lipid assignment. However, although lipids are identified based on MS/MS confirmation, a number of false positives are still observed. Here, we discuss several causes of introducing lipid false identifications in untargeted analysis. Phosphotidylcholines and cholesteryl esters generate in-source fragmentation to produce dimethylated phosphotidylethanolamine and free cholesterol. Dimerization of fatty acid results in false identification of fatty acid ester of hydroxyl fatty acid. Realizing these false positives is able to improve confidence of results acquired from untargeted analysis. Besides, thresholds are established for lipids identified using LipidSearch v4.1.16 software to reduce unreliable results. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. False-positive psychology: undisclosed flexibility in data collection and analysis allows presenting anything as significant.

    PubMed

    Simmons, Joseph P; Nelson, Leif D; Simonsohn, Uri

    2011-11-01

    In this article, we accomplish two things. First, we show that despite empirical psychologists' nominal endorsement of a low rate of false-positive findings (≤ .05), flexibility in data collection, analysis, and reporting dramatically increases actual false-positive rates. In many cases, a researcher is more likely to falsely find evidence that an effect exists than to correctly find evidence that it does not. We present computer simulations and a pair of actual experiments that demonstrate how unacceptably easy it is to accumulate (and report) statistically significant evidence for a false hypothesis. Second, we suggest a simple, low-cost, and straightforwardly effective disclosure-based solution to this problem. The solution involves six concrete requirements for authors and four guidelines for reviewers, all of which impose a minimal burden on the publication process.

  5. New Predictive Model at 11+0 to 13+6 Gestational Weeks for Early-Onset Preeclampsia With Fetal Growth Restriction.

    PubMed

    Chang, Ying; Chen, Xu; Cui, Hong-Yan; Li, Xing; Xu, Ya-Ling

    2017-05-01

    The aim of the present study was to determine a predictive model for early-onset preeclampsia with fetal growth restriction (FGR) to be used at 11 +0 to 13 +6 gestational weeks, by combining the maternal serum level of pregnancy-associated plasma protein-A (PAPP-A), placental growth factor (PLGF), placental protein 13 (PP13), soluble endoglin (sEng), mean arterial pressure (MAP), and uterine artery Doppler. This was a retrospective cohort study of 4453 pregnant women. Uterine artery Doppler examination was conducted in the first trimester. Maternal serum PAPP-A, PLGF, PP13, and sEng were measured. Mean arterial pressure was obtained. Women were classified as with/without early-onset preeclampsia, and women with preeclampsia were classified as with/without FGR. Receiver operating characteristic analysis was performed to determine the value of the model. There were 30 and 32 pregnant women with early-onset preeclampsia with and without FGR. The diagnosis rate of early-onset preeclampsia with FGR was 67.4% using the predictive model when the false positive rate was set at 5% and 73.2% when the false positive rate was 10%. The predictive model (MAP, uterine artery Doppler measurements, and serum biomarkers) had some predictive value for the early diagnosis (11 +0 to 13 +6 gestational weeks) of early-onset preeclampsia with FGR.

  6. Use of the sentinel node procedure to stage endometrial cancer.

    PubMed

    Ballester, Marcos; Dubernard, Gil; Rouzier, Roman; Barranger, Emmanuel; Darai, Emile

    2008-05-01

    Lymph node status is a major prognostic factor and a criterion for adjuvant therapy in endometrial cancer. The sentinel lymph node (SN) procedure has emerged as a possible alternative to systematic lymphadenectomy. The aims of this study were to determine the detection rate and the false-negative rate of the SN procedure, and its contribution to the staging of women with endometrial cancer. Forty-six patients with endometrial cancer underwent the sentinel node procedure followed by pelvic lymphadenectomy. SNs were detected with a dual or single labelling method in 39 and 7 cases, respectively. All SNs were analysed by both hematoxylin and eosin (H&E) staining and immunochemistry. SNs were identified in 40 patients (87%), whose mean number of SN was 2.6 (range 1-5). The SN detection rate was significantly lower with the single label than with the dual label (p = 0.01). Ten women (25%) had a positive SN on final histology (i.e. there were no false negatives). A correlation was observed between lymph node involvement and both histological grade (p = 0.01) and lymphovascular space involvement (p = 0.001). The stage predicted by magnetic resonance (MR) imaging correlated poorly with the Federation International of Gynaecology and Obstetrics (FIGO) stage. Among the ten women with a positive SN, three of the four women with a grade 1 tumour at biopsy had grade 2-3 disease on final histology. Seven of the ten women with a positive SN underwent external pelvic radiotherapy, based solely on their SN involvement. The SN procedure can reliably determine lymph node status in women with endometrial cancer. Given the limited capacity of MR imaging to detect myometrial invasion, and of biopsy to determine histological grade, our results support the systematic use of the SN procedure in women with endometrial cancer, including those with presumed early-stage disease and/or well-differentiated tumours.

  7. Diagnosing periprosthetic infection: false-positive intraoperative Gram stains.

    PubMed

    Oethinger, Margret; Warner, Debra K; Schindler, Susan A; Kobayashi, Hideo; Bauer, Thomas W

    2011-04-01

    Intraoperative Gram stains have a reported low sensitivity but high specificity when used to help diagnose periprosthetic infections. In early 2008, we recognized an unexpectedly high frequency of apparent false-positive Gram stains from revision arthroplasties. The purpose of this report is to describe the cause of these false-positive test results. We calculated the sensitivity and specificity of all intraoperative Gram stains submitted from revision arthroplasty cases during a 3-month interval using microbiologic cultures of the same samples as the gold standard. Methods of specimen harvesting, handling, transport, distribution, specimen processing including tissue grinding/macerating, Gram staining, and interpretation were studied. After a test modification, results of specimens were prospectively collected for a second 3-month interval, and the sensitivity and specificity of intraoperative Gram stains were calculated. The retrospective review of 269 Gram stains submitted from revision arthroplasties indicated historic sensitivity and specificity values of 23% and 92%, respectively. Systematic analysis of all steps of the procedure identified Gram-stained but nonviable bacteria in commercial broth reagents used as diluents for maceration of periprosthetic membranes before Gram staining and culture. Polymerase chain reaction and sequencing showed mixed bacterial DNA. Evaluation of 390 specimens after initiating standardized Millipore filtering of diluent fluid revealed a reduced number of positive Gram stains, yielding 9% sensitivity and 99% specificity. Clusters of false-positive Gram stains have been reported in other clinical conditions. They are apparently rare related to diagnosing periprosthetic infections but have severe consequences if used to guide treatment. Even occasional false-positive Gram stains should prompt review of laboratory methods. Our observations implicate dead bacteria in microbiologic reagents as potential sources of false-positive Gram stains.

  8. Risk of Breast Cancer in Women with False-Positive Results according to Mammographic Features.

    PubMed

    Castells, Xavier; Torá-Rocamora, Isabel; Posso, Margarita; Román, Marta; Vernet-Tomas, Maria; Rodríguez-Arana, Ana; Domingo, Laia; Vidal, Carmen; Baré, Marisa; Ferrer, Joana; Quintana, María Jesús; Sánchez, Mar; Natal, Carmen; Espinàs, Josep A; Saladié, Francina; Sala, María

    2016-08-01

    Purpose To assess the risk of breast cancer in women with false-positive screening results according to radiologic classification of mammographic features. Materials and Methods Review board approval was obtained, with waiver of informed consent. This retrospective cohort study included 521 200 women aged 50-69 years who underwent screening as part of the Spanish Breast Cancer Screening Program between 1994 and 2010 and who were observed until December 2012. Cox proportional hazards regression analysis was used to estimate the age-adjusted hazard ratio (HR) of breast cancer and the 95% confidence interval (CI) in women with false-positive mammograms as compared with women with negative mammograms. Separate models were adjusted for screen-detected and interval cancers and for screen-film and digital mammography. Time without a breast cancer diagnosis was plotted by using Kaplan-Meier curves. Results When compared with women with negative mammograms, the age-adjusted HR of cancer in women with false-positive results was 1.84 (95% CI: 1.73, 1.95; P < .001). The risk was higher in women who had calcifications, whether they were (HR, 2.73; 95% CI: 2.28, 3.28; P < .001) or were not (HR, 2.24; 95% CI: 2.02, 2.48; P < .001) associated with masses. Women in whom mammographic features showed changes in subsequent false-positive results were those who had the highest risk (HR, 9.13; 95% CI: 8.28, 10.07; P < .001). Conclusion Women with false-positive results had an increased risk of breast cancer, particularly women who had calcifications at mammography. Women who had more than one examination with false-positive findings and in whom the mammographic features changed over time had a highly increased risk of breast cancer. Previous mammographic features might yield useful information for further risk-prediction models and personalized follow-up screening protocols. (©) RSNA, 2016 Online supplemental material is available for this article.

  9. Experimental Null Method to Guide the Development of Technical Procedures and to Control False-Positive Discovery in Quantitative Proteomics.

    PubMed

    Shen, Xiaomeng; Hu, Qiang; Li, Jun; Wang, Jianmin; Qu, Jun

    2015-10-02

    Comprehensive and accurate evaluation of data quality and false-positive biomarker discovery is critical to direct the method development/optimization for quantitative proteomics, which nonetheless remains challenging largely due to the high complexity and unique features of proteomic data. Here we describe an experimental null (EN) method to address this need. Because the method experimentally measures the null distribution (either technical or biological replicates) using the same proteomic samples, the same procedures and the same batch as the case-vs-contol experiment, it correctly reflects the collective effects of technical variability (e.g., variation/bias in sample preparation, LC-MS analysis, and data processing) and project-specific features (e.g., characteristics of the proteome and biological variation) on the performances of quantitative analysis. To show a proof of concept, we employed the EN method to assess the quantitative accuracy and precision and the ability to quantify subtle ratio changes between groups using different experimental and data-processing approaches and in various cellular and tissue proteomes. It was found that choices of quantitative features, sample size, experimental design, data-processing strategies, and quality of chromatographic separation can profoundly affect quantitative precision and accuracy of label-free quantification. The EN method was also demonstrated as a practical tool to determine the optimal experimental parameters and rational ratio cutoff for reliable protein quantification in specific proteomic experiments, for example, to identify the necessary number of technical/biological replicates per group that affords sufficient power for discovery. Furthermore, we assessed the ability of EN method to estimate levels of false-positives in the discovery of altered proteins, using two concocted sample sets mimicking proteomic profiling using technical and biological replicates, respectively, where the true-positives/negatives are known and span a wide concentration range. It was observed that the EN method correctly reflects the null distribution in a proteomic system and accurately measures false altered proteins discovery rate (FADR). In summary, the EN method provides a straightforward, practical, and accurate alternative to statistics-based approaches for the development and evaluation of proteomic experiments and can be universally adapted to various types of quantitative techniques.

  10. Reliability of high- and low-field magnetic resonance imaging systems for detection of cartilage and bone lesions in the equine cadaver fetlock.

    PubMed

    Smith, M A; Dyson, S J; Murray, R C

    2012-11-01

    To determine the reliability of 2 magnetic resonance imaging (MRI) systems for detection of cartilage and bone lesions of the equine fetlock. To test the hypotheses that lesions in cartilage, subchondral and trabecular bone of the equine fetlock verified using histopathology can be detected on high- and low-field MR images with a low incidence of false positive or negative results; that low-field images are less reliable than high-field images for detection of cartilage lesions; and that combining results of interpretation from different pulse sequences increases detection of cartilage lesions. High- and low-field MRI was performed on 19 limbs from horses identified with fetlock lameness prior to euthanasia. Grading systems were used to score cartilage, subchondral and trabecular bone on MR images and histopathology. Sensitivity and specificity were calculated for images. High-field T2*-weighted gradient echo (T2*W-GRE) and low-field T2-weighted fast spin echo (T2W-FSE) images had high sensitivity but low specificity for detection of cartilage lesions. All pulse sequences had high sensitivity and low-moderate specificity for detection of subchondral bone lesions and moderate sensitivity and moderate-high specificity for detection of trabecular bone lesions (histopathology as gold standard). For detection of lesions of trabecular bone low-field T2*W-GRE images had higher sensitivity and specificity than T2W-FSE images. There is high likelihood of false positive results using high- or low-field MRI for detection of cartilage lesions and moderate-high likelihood of false positive results for detection of subchondral bone lesions compared with histopathology. Combining results of interpretation from different pulse sequences did not increase detection of cartilage lesions. MRI interpretation of trabecular bone was more reliable than cartilage or subchondral bone in both MR systems. Independent interpretation of a variety of pulse sequences may maximise detection of cartilage and bone lesions in the fetlock. Clinicians should be aware of potential false positive and negative results. © 2012 EVJ Ltd.

  11. Evaluation of grades 3 and 4 chondromalacia of the knee using T2*-weighted 3D gradient-echo articular cartilage imaging.

    PubMed

    Murphy, B J

    2001-06-01

    To determine the accuracy of T2*-weighted three-dimensional (3D) gradient-echo articular cartilage imaging in the identification of grades 3 and 4 chondromalacia of the knee. A retrospective evaluation of 80 patients who underwent both arthroscopic and MRI evaluation was performed. The 3D images were interpreted by one observer without knowledge of the surgical results. The medial and lateral femoral condyles, the medial and lateral tibial plateau, the patellar cartilage and trochlear groove were evaluated. MR cartilage images were considered positive if focal reduction of cartilage thickness was present (grade 3 chondromalacia) or if complete loss of cartilage was present (grade 4 chondromalacia). Comparison of the 3D MR results with the arthroscopic findings was performed. Eighty patients were included in the study group. A total of 480 articular cartilage sites were evaluated with MRI and arthroscopy. Results of MR identification of grades 3 and 4 chondromalacia, all sites combined, were: sensitivity 83%, specificity 97%, false negative rate 17%, false positive rate 3%, positive predictive value 87%, negative predictive value 95%, overall accuracy 93%. The results demonstrate that T2*-weighted 3D gradient-echo articular cartilage imaging can identify grades 3 and 4 chondromalacia of the knee.

  12. Differences in tuberculin reactivity as determined in a veterans administration employee health screening program.

    PubMed

    Mehta, Sanjay R; MacGruder, Cathy; Looney, David; Johns, Scott; Smith, Davey M

    2009-04-01

    In response to a difference in pricing, the San Diego Veterans Administration Medical Center changed its tuberculin preparation from Tubersol to Aplisol in the fall of 2006. Following the change, an increased number of employee skin test conversions was noted. Employee tuberculin skin test converters from 2006 were screened with the QuantiFERON Gold (QFT-G) gamma interferon release assay. Those employees who tested negative by QFT-G were asked to repeat their skin test with both Tubersol and Aplisol tuberculin preparations. Of the new purified protein derivative converters, 12 of 14 returned for repeat testing with QFT-G, and the assay was negative for 83% (10/12), positive for 8% (1/12), and indeterminate for 8% (1/12) of the individuals. Nine of the individuals who were QFT-G negative agreed to repeat skin testing with both tuberculin preparations, and 7/8 (87.5%) demonstrated reactivity with the Aplisol preparation, while 0/8 (0%) reacted to the Tubersol preparation. A change from Tubersol to Aplisol resulted in elevated tuberculin skin test conversion rates that may be due to false-positive reactions. The differences in skin test reactivity between preparations support CDC guidelines that recommend that institutions should not change tuberculin preparations, as doing so may falsely increase the number of positive reactions.

  13. Automatic lung nodule graph cuts segmentation with deep learning false positive reduction

    NASA Astrophysics Data System (ADS)

    Sun, Wenqing; Huang, Xia; Tseng, Tzu-Liang Bill; Qian, Wei

    2017-03-01

    To automatic detect lung nodules from CT images, we designed a two stage computer aided detection (CAD) system. The first stage is graph cuts segmentation to identify and segment the nodule candidates, and the second stage is convolutional neural network for false positive reduction. The dataset contains 595 CT cases randomly selected from Lung Image Database Consortium and Image Database Resource Initiative (LIDC/IDRI) and the 305 pulmonary nodules achieved diagnosis consensus by all four experienced radiologists were our detection targets. Consider each slice as an individual sample, 2844 nodules were included in our database. The graph cuts segmentation was conducted in a two-dimension manner, 2733 lung nodule ROIs are successfully identified and segmented. With a false positive reduction by a seven-layer convolutional neural network, 2535 nodules remain detected while the false positive dropped to 31.6%. The average F-measure of segmented lung nodule tissue is 0.8501.

  14. Verification of false-positive blood culture results generated by the BACTEC 9000 series by eubacterial 16S rDNA and panfungal 18S rDNA directed polymerase chain reaction (PCR).

    PubMed

    Daxboeck, Florian; Dornbusch, Hans Jürgen; Krause, Robert; Assadian, Ojan; Wenisch, Christoph

    2004-01-01

    A small but significant proportion of blood cultures processed by the BACTEC 9000 series systems is signaled positive, while subsequent Gram's stain and culture on solid media yield no pathogens. In this study, 15 "false-positive" vials (7 aerobes, 8 anaerobes) from 15 patients were investigated for the presence of bacteria and fungi by eubacterial 16S rDNA and panfungal 18S rDNA amplification, respectively. All samples turned out negative by both methods. Most patients (7) had neutropenia, which does not support the theory that high leukocyte counts enhance the generation of false-positive results. In conclusion, the results of this study indicate that false-negative results generated by the BACTEC 9000 series are inherent to the automated detection and not due to the growth of fastidious organisms.

  15. False positives in psychiatric diagnosis: implications for human freedom.

    PubMed

    Wakefield, Jerome C

    2010-02-01

    Current symptom-based DSM and ICD diagnostic criteria for mental disorders are prone to yielding false positives because they ignore the context of symptoms. This is often seen as a benign flaw because problems of living and emotional suffering, even if not true disorders, may benefit from support and treatment. However, diagnosis of a disorder in our society has many ramifications not only for treatment choice but for broader social reactions to the diagnosed individual. In particular, mental disorders impose a sick role on individuals and place a burden upon them to change; thus, disorders decrease the level of respect and acceptance generally accorded to those with even annoying normal variations in traits and features. Thus, minimizing false positives is important to a pluralistic society. The harmful dysfunction analysis of disorder is used to diagnose the sources of likely false positives, and propose potential remedies to the current weaknesses in the validity of diagnostic criteria.

  16. False positive malaria rapid diagnostic test in returning traveler with typhoid fever.

    PubMed

    Meatherall, Bonnie; Preston, Keith; Pillai, Dylan R

    2014-07-09

    Rapid diagnostic tests play a pivotal role in the early diagnosis of malaria where microscopy or polymerase chain reaction are not immediately available. We report the case of a 39 year old traveler to Canada who presented with fever, headache, and abdominal pain after visiting friends and relatives in India. While in India, the individual was not ill and had no signs or symptoms of malaria. Laboratory testing upon his return to Canada identified a false positive malaria rapid diagnostic (BinaxNOW® malaria) result for P. falciparum with coincident Salmonella Typhi bacteraemia without rheumatoid or autoimmune factors. Rapid diagnostic test false positivity for malaria coincided with the presence or absence of Salmonella Typhi in the blood. Clinicians should be aware that Salmonella Typhi infection may result in a false positive malaria rapid diagnostic test. The mechanism of this cross-reactivity is not clear.

  17. Negative affect promotes encoding of and memory for details at the expense of the gist: affect, encoding, and false memories.

    PubMed

    Storbeck, Justin

    2013-01-01

    I investigated whether negative affective states enhance encoding of and memory for item-specific information reducing false memories. Positive, negative, and neutral moods were induced, and participants then completed a Deese-Roediger-McDermott (DRM) false-memory task. List items were presented in unique spatial locations or unique fonts to serve as measures for item-specific encoding. The negative mood conditions had more accurate memories for item-specific information, and they also had fewer false memories. The final experiment used a manipulation that drew attention to distinctive information, which aided learning for DRM words, but also promoted item-specific encoding. For the condition that promoted item-specific encoding, false memories were reduced for positive and neutral mood conditions to a rate similar to that of the negative mood condition. These experiments demonstrated that negative affective cues promote item-specific processing reducing false memories. People in positive and negative moods encode events differently creating different memories for the same event.

  18. True detection limits in an experimental linearly heteroscedastic system. Part 1

    NASA Astrophysics Data System (ADS)

    Voigtman, Edward; Abraham, Kevin T.

    2011-11-01

    Using a lab-constructed laser-excited filter fluorimeter deliberately designed to exhibit linearly heteroscedastic, additive Gaussian noise, it has been shown that accurate estimates may be made of the true theoretical Currie decision levels ( YC and XC) and true Currie detection limits ( YD and XD) for the detection of rhodamine 6 G tetrafluoroborate in ethanol. The obtained experimental values, for 5% probability of false positives and 5% probability of false negatives, were YC = 56.1 mV, YD = 125. mV, XC = 0.132 μg /mL and XD = 0.294 μg /mL. For 5% probability of false positives and 1% probability of false negatives, the obtained detection limits were YD = 158. mV and XD = 0.372 μg /mL. These decision levels and corresponding detection limits were shown to pass the ultimate test: they resulted in observed probabilities of false positives and false negatives that were statistically equivalent to the a priori specified values.

  19. Computerized detection of unruptured aneurysms in MRA images: reduction of false positives using anatomical location features

    NASA Astrophysics Data System (ADS)

    Uchiyama, Yoshikazu; Gao, Xin; Hara, Takeshi; Fujita, Hiroshi; Ando, Hiromichi; Yamakawa, Hiroyasu; Asano, Takahiko; Kato, Hiroki; Iwama, Toru; Kanematsu, Masayuki; Hoshi, Hiroaki

    2008-03-01

    The detection of unruptured aneurysms is a major subject in magnetic resonance angiography (MRA). However, their accurate detection is often difficult because of the overlapping between the aneurysm and the adjacent vessels on maximum intensity projection images. The purpose of this study is to develop a computerized method for the detection of unruptured aneurysms in order to assist radiologists in image interpretation. The vessel regions were first segmented using gray-level thresholding and a region growing technique. The gradient concentration (GC) filter was then employed for the enhancement of the aneurysms. The initial candidates were identified in the GC image using a gray-level threshold. For the elimination of false positives (FPs), we determined shape features and an anatomical location feature. Finally, rule-based schemes and quadratic discriminant analysis were employed along with these features for distinguishing between the aneurysms and the FPs. The sensitivity for the detection of unruptured aneurysms was 90.0% with 1.52 FPs per patient. Our computerized scheme can be useful in assisting the radiologists in the detection of unruptured aneurysms in MRA images.

  20. Effect of the Protein Corona on Antibody-Antigen Binding in Nanoparticle Sandwich Immunoassays.

    PubMed

    de Puig, Helena; Bosch, Irene; Carré-Camps, Marc; Hamad-Schifferli, Kimberly

    2017-01-18

    We investigated the effect of the protein corona on the function of nanoparticle (NP) antibody (Ab) conjugates in dipstick sandwich immunoassays. Ab specific for Zika virus nonstructural protein 1 (NS1) were conjugated to gold NPs, and another anti-NS1 Ab was immobilized onto the nitrocellulose membrane. Sandwich immunoassay formation was influenced by whether the strip was run in corona forming conditions, i.e., in human serum. Strips run in buffer or pure solutions of bovine serum albumin exhibited false positives, but those run in human serum did not. Serum pretreatment of the nitrocellulose also eliminated false positives. Corona formation around the NP-Ab in serum was faster than the immunoassay time scale. Langmuir binding analysis determined how the immobilized Ab affinity for the NP-Ab/NS1 was impacted by corona formation conditions, quantified as an effective dissociation constant, K D eff . Results show that corona formation mediates the specificity and sensitivity of the antibody-antigen interaction of Zika biomarkers in immunoassays, and plays a critical but beneficial role.

  1. Analysis of Hypodermic Needles and Syringes for the Presence of Blood and Polydimethylsiloxane (Silicone) Utilizing Microchemical Tests and Infrared Spectroscopy.

    PubMed

    Crowe, John B; Lanzarotta, Adam; Witkowski, Mark R; Andria, Sara E

    2015-07-01

    Suspect hypodermic needles and syringes were seized from an unlicensed individual who was allegedly injecting patients with silicone (polydimethylsiloxane [PDMS]) for cosmetic enhancement. Since control syringe barrels and needles often contain an interfering PDMS lubricant, a risk for false positives of foreign PDMS exists. The focus of this report was to minimize this risk and determine a quick and reliable test for the presence of blood in PDMS matrices. Using ATR-FT-IR spectroscopy, the risk for false-positive identification of foreign PDMS was reduced by (i) overfilling the sampling aperture to prevent spectral distortions and (ii) sampling a region of the suspect syringe/needle assembly where manufacturer-applied PDMS is not typically located. Analysis for blood indicated that the Teichman microchemical test was effective for detecting blood in the presence of PDMS. Overall, detecting PDMS established intent and detecting blood established that the needle containing the PDMS had been used for injection. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.

  2. Cerebral microbleed detection in traumatic brain injury patients using 3D convolutional neural networks

    NASA Astrophysics Data System (ADS)

    Standvoss, K.; Crijns, T.; Goerke, L.; Janssen, D.; Kern, S.; van Niedek, T.; van Vugt, J.; Alfonso Burgos, N.; Gerritse, E. J.; Mol, J.; van de Vooren, D.; Ghafoorian, M.; van den Heuvel, T. L. A.; Manniesing, R.

    2018-02-01

    The number and location of cerebral microbleeds (CMBs) in patients with traumatic brain injury (TBI) is important to determine the severity of trauma and may hold prognostic value for patient outcome. However, manual assessment is subjective and time-consuming due to the resemblance of CMBs to blood vessels, the possible presence of imaging artifacts, and the typical heterogeneity of trauma imaging data. In this work, we present a computer aided detection system based on 3D convolutional neural networks for detecting CMBs in 3D susceptibility weighted images. Network architectures with varying depth were evaluated. Data augmentation techniques were employed to improve the networks' generalization ability and selective sampling was implemented to handle class imbalance. The predictions of the models were clustered using a connected component analysis. The system was trained on ten annotated scans and evaluated on an independent test set of eight scans. Despite this limited data set, the system reached a sensitivity of 0.87 at 16.75 false positives per scan (2.5 false positives per CMB), outperforming related work on CMB detection in TBI patients.

  3. A False Positive Dengue Fever Rapid Diagnostic Test Result in a Case of Acute Parvovirus B19 Infection.

    PubMed

    Izumida, Toshihide; Sakata, Hidenao; Nakamura, Masahiko; Hayashibara, Yumiko; Inasaki, Noriko; Inahata, Ryo; Hasegawa, Sumiyo; Takizawa, Takenori; Kaya, Hiroyasu

    2016-01-01

    An outbreak of dengue fever occurred in Japan in August 2014. We herein report the case of a 63-year-old man who presented with a persistent fever in September 2014. Acute parvovirus B19 infection led to a false positive finding of dengue fever on a rapid diagnostic test (Panbio Dengue Duo Cassette(TM)). To the best of our knowledge, there are no previous reports of a false positive result for dengue IgM with the dengue rapid diagnostic test. We believe that epidemiological information on the prevalence of parvovirus B19 is useful for guiding the interpretation of a positive result with the dengue rapid diagnostic test.

  4. Two-step glutamate dehydrogenase antigen real-time polymerase chain reaction assay for detection of toxigenic Clostridium difficile.

    PubMed

    Goldenberg, S D; Cliff, P R; Smith, S; Milner, M; French, G L

    2010-01-01

    Current diagnosis of Clostridium difficile infection (CDI) relies upon detection of toxins A/B in stool by enzyme immunoassay [EIA(A/B)]. This strategy is unsatisfactory because it has a low sensitivity resulting in significant false negatives. We investigated the performance of a two-step algorithm for diagnosis of CDI using detection of glutamate dehydrogenase (GDH). GDH-positive samples were tested for C. difficile toxin B gene (tcdB) by polymerase chain reaction (PCR). The performance of the two-step protocol was compared with toxin detection by the Meridian Premier EIA kit in 500 consecutive stool samples from patients with suspected CDI. The reference standard among samples that were positive by either EIA(A/B) or GDH testing was culture cytotoxin neutralisation (culture/CTN). Thirty-six (7%) of 500 samples were identified as true positives by culture/CTN. EIA(A/B) identified 14 of the positive specimens with 22 false negatives and two false positives. The two-step protocol identified 34 of the positive samples with two false positives and two false negatives. EIA(A/B) had a sensitivity of 39%, specificity of 99%, positive predictive value of 88% and negative predictive value of 95%. The two-step algorithm performed better, with corresponding values of 94%, 99%, 94% and 99% respectively. Screening for GDH before confirmation of positives by PCR is cheaper than screening all specimens by PCR and is an effective method for routine use. Current EIA(A/B) tests for CDI are of inadequate sensitivity and should be replaced; however, this may result in apparent changes in CDI rates that would need to be explained in national surveillance statistics. Copyright 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  5. Wavelet method for CT colonography computer-aided polyp detection.

    PubMed

    Li, Jiang; Van Uitert, Robert; Yao, Jianhua; Petrick, Nicholas; Franaszek, Marek; Huang, Adam; Summers, Ronald M

    2008-08-01

    Computed tomographic colonography (CTC) computer aided detection (CAD) is a new method to detect colon polyps. Colonic polyps are abnormal growths that may become cancerous. Detection and removal of colonic polyps, particularly larger ones, has been shown to reduce the incidence of colorectal cancer. While high sensitivities and low false positive rates are consistently achieved for the detection of polyps sized 1 cm or larger, lower sensitivities and higher false positive rates occur when the goal of CAD is to identify "medium"-sized polyps, 6-9 mm in diameter. Such medium-sized polyps may be important for clinical patient management. We have developed a wavelet-based postprocessor to reduce false positives for this polyp size range. We applied the wavelet-based postprocessor to CTC CAD findings from 44 patients in whom 45 polyps with sizes of 6-9 mm were found at segmentally unblinded optical colonoscopy and visible on retrospective review of the CT colonography images. Prior to the application of the wavelet-based postprocessor, the CTC CAD system detected 33 of the polyps (sensitivity 73.33%) with 12.4 false positives per patient, a sensitivity comparable to that of expert radiologists. Fourfold cross validation with 5000 bootstraps showed that the wavelet-based postprocessor could reduce the false positives by 56.61% (p <0.001), to 5.38 per patient (95% confidence interval [4.41, 6.34]), without significant sensitivity degradation (32/45, 71.11%, 95% confidence interval [66.39%, 75.74%], p=0.1713). We conclude that this wavelet-based postprocessor can substantially reduce the false positive rate of our CTC CAD for this important polyp size range.

  6. Mobile chemical detector (AP2C+SP4E) as an aid for medical decision making in the battlefield.

    PubMed

    Eisenkraft, Arik; Markel, Gal; Simovich, Shirley; Layish, Ido; Hoffman, Azik; Finkelstein, Arseny; Rotman, Eran; Dushnitsky, Tsvika; Krivoy, Amir

    2007-09-01

    The combination of the AP2C unit with the SP4E kit composes a lightweight mobile detector of chemical warfare agents (CWA), such as nerve and mustard agents, with both vapor- and liquid-sampling capabilities. This apparatus was recently introduced into our military medical units as an aid for detection of CWA on casualties. Importantly, critical information regarding the applicability in the battlefield was absent. In view of the serious consequences that might follow a proclamation of CWA recognition in battlefield, a high false-positive rate positions the utilization of this apparatus as a medical decision tool in question. We have therefore conducted a field experiment to test the false-positive rate as well as analyze possible factors leading to false-positive readings with this device. The experiment was carried out before and after a 4-day army field exercise, using a standard AP2C device, a SP4E surface sampling kit, and a specially designed medical sampling kit for casualties, intended for medical teams. Soldiers were examined at rest, after mild exercise, and after 4 days in the field. The readings with AP2C alone were compared to the combination of AP2C and SP4E and to the medical sampling kit. Various body fluids served as negative controls. Remarkably, we found a false-positive rate of 57% at rest and after mild exercise, and an even higher rate of 64% after the 4-day field exercise with the AP2C detector alone, as compared to almost no false-positive readings with the combination of AP2C and SP4E. Strikingly, the medical sampling kit has yielded numerous false-positive readings, even in normal body fluids such as blood, urine, and saliva. We therefore see no place for using the medical sampling kit due to an unaccepted high rate of false-positive readings. Finally, we have designed an algorithm that uses the entire apparatus of AP2C and SP4E as a reliable validation tool for medical triage in the setting of exposure to nerve agents in the battlefield.

  7. Foraging Parameters Influencing the Detection and Interpretation of Area-Restricted Search Behaviour in Marine Predators: A Case Study with the Masked Booby

    PubMed Central

    Sommerfeld, Julia; Kato, Akiko; Ropert-Coudert, Yan; Garthe, Stefan; Hindell, Mark A.

    2013-01-01

    Identification of Area-restricted search (ARS) behaviour is used to better understand foraging movements and strategies of marine predators. Track-based descriptive analyses are commonly used to detect ARS behaviour, but they may be biased by factors such as foraging trip duration or non-foraging behaviours (i.e. resting on the water). Using first-passage time analysis we tested if (I) daylight resting at the sea surface positions falsely increase the detection of ARS behaviour and (II) short foraging trips are less likely to include ARS behaviour in Masked Boobies Sula dactylatra. We further analysed whether ARS behaviour may be used as a proxy to identify important feeding areas. Depth-acceleration and GPS-loggers were simultaneously deployed on chick-rearing adults to obtain (1) location data every 4 minutes and (2) detailed foraging activity such as diving rates, time spent sitting on the water surface and in flight. In 82% of 50 foraging trips, birds adopted ARS behaviour. In 19.3% of 57 detected ARS zones, birds spent more than 70% of total ARS duration resting on the water, suggesting that these ARS zones were falsely detected. Based on generalized linear mixed models, the probability of detecting false ARS zones was 80%. False ARS zones mostly occurred during short trips in close proximity to the colony, with low or no diving activity. This demonstrates the need to account for resting on the water surface positions in marine animals when determining ARS behaviour based on foraging locations. Dive rates were positively correlated with trip duration and the probability of ARS behaviour increased with increasing number of dives, suggesting that the adoption of ARS behaviour in Masked Boobies is linked to enhanced foraging activity. We conclude that ARS behaviour may be used as a proxy to identify important feeding areas in this species. PMID:23717471

  8. Predictive performance of the Vitrigel-eye irritancy test method using 118 chemicals.

    PubMed

    Yamaguchi, Hiroyuki; Kojima, Hajime; Takezawa, Toshiaki

    2016-08-01

    We recently developed a novel Vitrigel-eye irritancy test (EIT) method. The Vitrigel-EIT method is composed of two parts, i.e., the construction of a human corneal epithelium (HCE) model in a collagen vitrigel membrane chamber and the prediction of eye irritancy by analyzing the time-dependent profile of transepithelial electrical resistance values for 3 min after exposing a chemical to the HCE model. In this study, we estimated the predictive performance of Vitrigel-EIT method by testing a total of 118 chemicals. The category determined by the Vitrigel-EIT method in comparison to the globally harmonized system classification revealed that the sensitivity, specificity and accuracy were 90.1%, 65.9% and 80.5%, respectively. Here, five of seven false-negative chemicals were acidic chemicals inducing the irregular rising of transepithelial electrical resistance values. In case of eliminating the test chemical solutions showing pH 5 or lower, the sensitivity, specificity and accuracy were improved to 96.8%, 67.4% and 84.4%, respectively. Meanwhile, nine of 16 false-positive chemicals were classified irritant by the US Environmental Protection Agency. In addition, the disappearance of ZO-1, a tight junction-associated protein and MUC1, a cell membrane-spanning mucin was immunohistologically confirmed in the HCE models after exposing not only eye irritant chemicals but also false-positive chemicals, suggesting that such false-positive chemicals have an eye irritant potential. These data demonstrated that the Vitrigel-EIT method could provide excellent predictive performance to judge the widespread eye irritancy, including very mild irritant chemicals. We hope that the Vitrigel-EIT method contributes to the development of safe commodity chemicals. Copyright © 2015 The Authors. Journal of Applied Toxicology published by John Wiley & Sons Ltd. Copyright © 2015 The Authors. Journal of Applied Toxicology published by John Wiley & Sons Ltd.

  9. Foraging parameters influencing the detection and interpretation of area-restricted search behaviour in marine predators: a case study with the masked booby.

    PubMed

    Sommerfeld, Julia; Kato, Akiko; Ropert-Coudert, Yan; Garthe, Stefan; Hindell, Mark A

    2013-01-01

    Identification of Area-restricted search (ARS) behaviour is used to better understand foraging movements and strategies of marine predators. Track-based descriptive analyses are commonly used to detect ARS behaviour, but they may be biased by factors such as foraging trip duration or non-foraging behaviours (i.e. resting on the water). Using first-passage time analysis we tested if (I) daylight resting at the sea surface positions falsely increase the detection of ARS behaviour and (II) short foraging trips are less likely to include ARS behaviour in Masked Boobies Sula dactylatra. We further analysed whether ARS behaviour may be used as a proxy to identify important feeding areas. Depth-acceleration and GPS-loggers were simultaneously deployed on chick-rearing adults to obtain (1) location data every 4 minutes and (2) detailed foraging activity such as diving rates, time spent sitting on the water surface and in flight. In 82% of 50 foraging trips, birds adopted ARS behaviour. In 19.3% of 57 detected ARS zones, birds spent more than 70% of total ARS duration resting on the water, suggesting that these ARS zones were falsely detected. Based on generalized linear mixed models, the probability of detecting false ARS zones was 80%. False ARS zones mostly occurred during short trips in close proximity to the colony, with low or no diving activity. This demonstrates the need to account for resting on the water surface positions in marine animals when determining ARS behaviour based on foraging locations. Dive rates were positively correlated with trip duration and the probability of ARS behaviour increased with increasing number of dives, suggesting that the adoption of ARS behaviour in Masked Boobies is linked to enhanced foraging activity. We conclude that ARS behaviour may be used as a proxy to identify important feeding areas in this species.

  10. False Positive and False Negative Effects on Network Attacks

    NASA Astrophysics Data System (ADS)

    Shang, Yilun

    2018-01-01

    Robustness against attacks serves as evidence for complex network structures and failure mechanisms that lie behind them. Most often, due to detection capability limitation or good disguises, attacks on networks are subject to false positives and false negatives, meaning that functional nodes may be falsely regarded as compromised by the attacker and vice versa. In this work, we initiate a study of false positive/negative effects on network robustness against three fundamental types of attack strategies, namely, random attacks (RA), localized attacks (LA), and targeted attack (TA). By developing a general mathematical framework based upon the percolation model, we investigate analytically and by numerical simulations of attack robustness with false positive/negative rate (FPR/FNR) on three benchmark models including Erdős-Rényi (ER) networks, random regular (RR) networks, and scale-free (SF) networks. We show that ER networks are equivalently robust against RA and LA only when FPR equals zero or the initial network is intact. We find several interesting crossovers in RR and SF networks when FPR is taken into consideration. By defining the cost of attack, we observe diminishing marginal attack efficiency for RA, LA, and TA. Our finding highlights the potential risk of underestimating or ignoring FPR in understanding attack robustness. The results may provide insights into ways of enhancing robustness of network architecture and improve the level of protection of critical infrastructures.

  11. Obesity prevalence and accuracy of BMI-defined obesity in Russian firefighters.

    PubMed

    Gurevich, K G; Poston, W S C; Anders, B; Ivkina, M A; Archangelskaya, A; Jitnarin, N; Starodubov, V I

    2017-01-01

    No data exist on obesity or the accuracy of body mass index (BMI) in Russian Federation firefighters. To determine the prevalence of obesity and rates of misclassification of BMI-based obesity status. Career firefighters in the Moscow region completed anthropometric assessments including height, weight, BMI, body fat per cent (BF%) and waist circumference (WC). Using these three methods, we defined obesity as BMI ≥30, BF% >25 and WC >102, respectively. The study group consisted of 167 male firefighters. Obesity prevalence was 22% for BMI [95% confidence interval (CI) 16.9-28.5], 60% for BF% (95% CI 52.5-67.3) and 28% for WC (95% CI 21.3-34.9). False positive rates for BMI-based obesity status were low, with 3% (95% CI -1.1 to 7.1) and 6% (95% CI 1.6-9.9) of non-obese participants defined by BF% and WC standards misidentified as obese using BMI. However, 65% (95% CI 55.7-77.4) of BF%-defined obese participants and 36% (95% CI 22.5-49.9) of WC-defined obese participants were misclassified as non-obese using BMI (i.e. false negatives). Rates of BMI-based obesity in Russian male firefighters were similar to that of males in the general Russian adult male population. Compared with BF% or WC standards, BMI-based obesity classi- fication produced low rates of false positives but demonstrated high rates of false negatives. © The Author 2016. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. The correct estimate of the probability of false detection of the matched filter in weak-signal detection problems

    NASA Astrophysics Data System (ADS)

    Vio, R.; Andreani, P.

    2016-05-01

    The reliable detection of weak signals is a critical issue in many astronomical contexts and may have severe consequences for determining number counts and luminosity functions, but also for optimizing the use of telescope time in follow-up observations. Because of its optimal properties, one of the most popular and widely-used detection technique is the matched filter (MF). This is a linear filter designed to maximise the detectability of a signal of known structure that is buried in additive Gaussian random noise. In this work we show that in the very common situation where the number and position of the searched signals within a data sequence (e.g. an emission line in a spectrum) or an image (e.g. a point-source in an interferometric map) are unknown, this technique, when applied in its standard form, may severely underestimate the probability of false detection. This is because the correct use of the MF relies upon a priori knowledge of the position of the signal of interest. In the absence of this information, the statistical significance of features that are actually noise is overestimated and detections claimed that are actually spurious. For this reason, we present an alternative method of computing the probability of false detection that is based on the probability density function (PDF) of the peaks of a random field. It is able to provide a correct estimate of the probability of false detection for the one-, two- and three-dimensional case. We apply this technique to a real two-dimensional interferometric map obtained with ALMA.

  13. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    PubMed

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2018-06-01

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P < .05). The diagnostic accuracy was best in nodules of 5 to 10 mm in diameter. The sensitivity, accuracy, PPV, and LR for negative US-guided FNA results were better in nodules with a size range of 5 to 15 mm. The specificity, negative predictive value (NPV), and LR for positive results and the Youden index rose with increasing nodule size. Seventeen false-positive and 60 false-negative results were found in this study. The false-negative rate rose with increasing nodule size. However, the false-positive rate was highest in the group containing the smallest nodules. Nodules with circumscribed margins and those that were nonsolid and nonhypoechoic and had no microcalcifications correlated with Bethesda I FNA results. Nodules with circumscribed margins and those that were nonsolid, heterogeneous, and nonhypoechoic and had increased vascularity correlated with false-negative FNA results. Borders correlated with Bethesda I false-negative and false-positive FNA results. Tiny nodules (≤5 mm) with obscure borders tended to yield false-positive FNA results. Large nodules (>20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  14. Mood and the DRM paradigm: An investigation of the effects of valence and arousal on false memory.

    PubMed

    Van Damme, Ilse

    2013-06-01

    Recent studies regarding the effect of mood on the DRM (Deese-Roediger-McDermott) illusion have not been able to clearly establish yet whether valence or arousal is most critical in determining susceptibility to false memories, nor what the underlying processes are. In three experiments, both the valence and the level of arousal of participants' mood were manipulated. Six conditions were used: positive mood with high/low arousal, negative mood with high/low arousal, neutral mood, and a control condition. Memory was tested by means of immediate and delayed recognition and immediate free recall. The mood induction procedure was effective. For recognition memory, there was an effect of arousal on the endorsement of critical lures. Low-arousal moods elicited more false recognition than high-arousal moods, regardless of valence. Based on signal detection analyses, the effect was attributed to more liberal response criteria with low arousal, in combination with a tendency towards improved item-specific memory with high arousal.

  15. Evaluation of DuPont Qualicon Bax System PCR assay for yeast and mold.

    PubMed

    Wallace, F Morgan; Burns, Frank; Fleck, Lois; Andaloro, Bridget; Farnum, Andrew; Tice, George; Ruebl, Joanne

    2010-01-01

    Evaluations were conducted to test the performance of the BAX System PCR assay which was certified as Performance Tested Method 010902 for screening yeast and mold in yogurt, corn starch, and milk-based powdered infant formula. Method comparison studies performed on samples with low-level inoculates showed that the BAX System demonstrates a sensitivity equivalent to the U.S. Food and Drug Administration's Bacteriological Analytical Manual culture method, but with a significantly shorter time to obtain results. Tests to evaluate inclusivity and exclusivity returned no false-negative and no false-positive results on a diverse panel of isolates, and tests for lot-to-lot variability and tablet stability demonstrated consistent performance. Ruggedness studies determined that none of the factors examined affected the performance of the assay.

  16. Feline focus: Diagnostic testing for feline thyroid disease: hypothyroidism.

    PubMed

    Peterson, Mark E

    2013-08-01

    Although naturally occurring hypothyroidism is very rare in cats, iatrogenic hypothyroidism is a recognized complication of treatment for hyperthyroidism. However, confirming the diagnosis of hypothyroidism in cats is not generally straightforward. The potential for false-negative and false-positive results exists with all thyroid function tests, especially in older cats that may have concurrent nonthyroidal illness. Therefore, all thyroid function test results must be interpreted in light of the cat's history, clinical signs, and other laboratory findings. If a low to low-normal serum thyroxine (T4) value is found in a cat that has been treated for hyperthyroidism, repeating the total T4 analysis, determining free T4 and thyroid stimulating hormone (TSH) concentrations, or performing a TSH stimulation test or thyroid scintigraphy may be needed to confirm the diagnosis.

  17. Neural events that underlie remembering something that never happened.

    PubMed

    Gonsalves, B; Paller, K A

    2000-12-01

    We induced people to experience a false-memory illusion by first asking them to visualize common objects when cued with the corresponding word; on some trials, a photograph of the object was presented 1800 ms after the cue word. We then tested their memory for the photographs. Posterior brain potentials in response to words at encoding were more positive if the corresponding object was later falsely remembered as a photograph. Similar brain potentials during the memory test were more positive for true than for false memories. These results implicate visual imagery in the generation of false memories and provide neural correlates of processing differences between true and false memories.

  18. MR-Guided Near Infrared Spectroscopy for Reducing Breast Cancer False Positives

    DTIC Science & Technology

    2009-09-01

    an Invivo breast coil in a (b) Philips scanner , and (b) a USA Instruments coil in a (d) GE scanner . 8 Quantitative accuracy in optical imaging...reconstruction [7], which includes a weighting term to account for the accuracy of the MR scanner in determining water and fat images. The advantage of... scanner used in this study. These methods were tested in a 86mm diameter gelatin phantom, shown in Figure 6, with porcine blood added to mimic the

  19. Likelihood of early detection of breast cancer in relation to false-positive risk in life-time mammographic screening: population-based cohort study.

    PubMed

    Otten, J D M; Fracheboud, J; den Heeten, G J; Otto, S J; Holland, R; de Koning, H J; Broeders, M J M; Verbeek, A L M

    2013-10-01

    Women require balanced, high-quality information when making an informed decision on screening benefits and harms before attending biennial mammographic screening. The cumulative risk of a false-positive recall and/or (small) screen-detected or interval cancer over 13 consecutive screening examinations for women aged 50 from the start of screening were estimated using data from the Nijmegen programme, the Netherlands. Women who underwent 13 successive screens in the period 1975-1976 had a 5.3% cumulative chance of a screen-detected cancer, with a 4.2% risk of at least one false-positive recall. The risk of being diagnosed with interval cancer was 3.7%. Two decades later, these estimates were 6.9%, 7.3% and 2.9%, respectively. The chance of detection of a small, favourable invasive breast cancer, anticipating a normal life-expectancy, rose from 2.3% to 3.7%. Extrapolation to digital screening mammography indicates that the proportion of false-positive results will rise to 16%. Dutch women about to participate in the screening programme can be reassured that the chance of false-positive recall in the Netherlands is relatively low. A new screening policy and improved mammography have increased the detection of an early screening carcinoma and lowering the risk of interval carcinoma.

  20. False-positive results in pharmacoepidemiology and pharmacovigilance.

    PubMed

    Bezin, Julien; Bosco-Levy, Pauline; Pariente, Antoine

    2017-09-01

    False-positive constitute an important issue in scientific research. In the domain of drug evaluation, it affects all phases of drug development and assessment, from the very early preclinical studies to the late post-marketing evaluations. The core concern associated with this false-positive is the lack of replicability of the results. Aside from fraud or misconducts, false-positive is often envisioned from the statistical angle, which considers them as a price to pay for type I error in statistical testing, and its inflation in the context of multiple testing. If envisioning this problematic in the context of pharmacoepidemiology and pharmacovigilance however, that both evaluate drugs in an observational settings, information brought by statistical testing and the significance of such should only be considered as additional to the estimates provided and their confidence interval, in a context where differences have to be a clinically meaningful upon everything, and the results appear robust to the biases likely to have affected the studies. In the following article, we consequently illustrate these biases and their consequences in generating false-positive results, through studies and associations between drug use and health outcomes that have been widely disputed. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.

  1. Discordant HIV Test Results: Implications on Perinatal and Haemotransfusion Screening for HIV Infection, Cape Coast, Ghana.

    PubMed

    Tetteh, Ato Kwamena; Agyarko, Edward

    2017-01-01

    Screening results of 488 pregnant women aged 15-44 years whose blood samples had been tested on-site, using First Response® HIV 1/2, and confirmed with INNO-LIA™ HIV I/II Score were used. Of this total, 178 were reactive (HIV I, 154; HIV II, 2; and HIV I and HIV II, 22). Of the 154 HIV I-reactive samples, 104 were confirmed to be HIV I-positive and 2 were confirmed to be HIV II-positive, while 48 were confirmed to be negative [false positive rate = 17.44% (13.56-21.32)]. The two HIV II samples submitted were confirmed to be negative with the confirmatory test. For the 22 HIV I and HIV II samples, 7 were confirmed to be HIV I-positive and 1 was confirmed to be HIV I- and HIV II-positive, while 14 were confirmed to be negative. Of the 310 nonreactive samples, 6 were confirmed to be HIV I-positive and 1 was confirmed to be HIV II-positive [false negative rate = 5.79% (1.63-8.38)], while 303 were negative. False negative outcomes will remain unconfirmed, with no management options for the client. False negative rate of 5.79% requires attention, as its resultant implications on control of HIV/AIDS could be dire.

  2. Lymphatic Mapping and Sentinel Lymph Node Biopsy in Women With Squamous Cell Carcinoma of the Vulva: A Gynecologic Oncology Group Study

    PubMed Central

    Levenback, Charles F.; Ali, Shamshad; Coleman, Robert L.; Gold, Michael A.; Fowler, Jeffrey M.; Judson, Patricia L.; Bell, Maria C.; De Geest, Koen; Spirtos, Nick M.; Potkul, Ronald K.; Leitao, Mario M.; Bakkum-Gamez, Jamie N.; Rossi, Emma C.; Lentz, Samuel S.; Burke, James J.; Van Le, Linda; Trimble, Cornelia L.

    2012-01-01

    Purpose To determine the safety of sentinel lymph node biopsy as a replacement for inguinal femoral lymphadenectomy in selected women with vulvar cancer. Patients and Methods Eligible women had squamous cell carcinoma, at least 1-mm invasion, and tumor size ≥ 2 cm and ≤ 6 cm. The primary tumor was limited to the vulva, and there were no groin lymph nodes that were clinically suggestive of cancer. All women underwent intraoperative lymphatic mapping, sentinel lymph node biopsy, and inguinal femoral lymphadenectomy. Histologic ultra staging of the sentinel lymph node was prescribed. Results In all, 452 women underwent the planned procedures, and 418 had at least one sentinel lymph node identified. There were 132 node-positive women, including 11 (8.3%) with false-negative nodes. Twenty-three percent of the true-positive patients were detected by immunohistochemical analysis of the sentinel lymph node. The sensitivity was 91.7% (90% lower confidence bound, 86.7%) and the false-negative predictive value (1-negative predictive value) was 3.7% (90% upper confidence bound, 6.1%). In women with tumor less than 4 cm, the false-negative predictive value was 2.0% (90% upper confidence bound, 4.5%). Conclusion Sentinel lymph node biopsy is a reasonable alternative to inguinal femoral lymphadenectomy in selected women with squamous cell carcinoma of the vulva. PMID:22753905

  3. Relationship between methamphetamine use history and segmental hair analysis findings of MA users.

    PubMed

    Han, Eunyoung; Lee, Sangeun; In, Sanghwan; Park, Meejung; Park, Yonghoon; Cho, Sungnam; Shin, Junguk; Lee, Hunjoo

    2015-09-01

    The aim of this study was to investigate the relationship between methamphetamine (MA) use history and segmental hair analysis (1 and 3cm sections) and whole hair analysis results in Korean MA users in rehabilitation programs. Hair samples were collected from 26 Korean MA users. Eleven of the 26 subjects used cannabis with MA and two used cocaine, opiates, and MDMA with MA. Self-reported single dose of MA from the 26 subjects ranged from 0.03 to 0.5g/one time. Concentrations of MA and its metabolite amphetamine (AP) in hair were determined by gas chromatography mass spectrometry (GC/MS) after derivatization. The method used was well validated. Qualitative analysis from all 1cm sections (n=154) revealed a good correlation between positive or negative results for MA in hair and self-reported MA use (69.48%, n=107). In detail, MA results were positive in 66 hair specimens of MA users who reported administering MA, and MA results were negative in 41 hair specimens of MA users who denied MA administration in the corresponding month. Test results were false-negative in 10.39% (n=16) of hair specimens and false-positive in 20.13% (n=31) of hair specimens. In false positive cases, it is considered that after MA cessation it continued to be accumulated in hair still, while in false negative cases, self-reported histories showed a small amount of MA use or MA use 5-7 months previously. In terms of quantitative analysis, the concentrations of MA in 1 and 3cm long hair segments and in whole hair samples ranged from 1.03 to 184.98 (mean 22.01), 2.26 to 89.33 (mean 18.71), and 0.91 to 124.49 (mean 15.24)ng/mg, respectively. Ten subjects showed a good correlation between MA use and MA concentration in hair. Correlation coefficient (r) of 7 among 10 subjects ranged from 0.71 to 0.98 (mean 0.85). Four subjects showed a low correlation between MA use and MA concentration in hair. Correlation coefficient (r) of 4 subjects ranged from 0.36 to 0.55. Eleven subjects showed a poor correlation between MA use and MA concentration in hair. Correlation between MA use and MA concentration in hair of remaining one subject could not be determined or calculated. In this study, the correlation between accurate MA use histories obtained by psychiatrists and well-trained counselors and MA concentrations in hair was shown. This report provides objective scientific findings that should considerably aid the interpretation of forensic results and of the results of trials related to MA use. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. [Evaluation of performance of five bioinformatics software for the prediction of missense mutations].

    PubMed

    Chen, Qianting; Dai, Congling; Zhang, Qianjun; Du, Juan; Li, Wen

    2016-10-01

    To study the prediction performance evaluation with five kinds of bioinformatics software (SIFT, PolyPhen2, MutationTaster, Provean, MutationAssessor). From own database for genetic mutations collected over the past five years, Chinese literature database, Human Gene Mutation Database, and dbSNP, 121 missense mutations confirmed by functional studies, and 121 missense mutations suspected to be pathogenic by pedigree analysis were used as positive gold standard, while 242 missense mutations with minor allele frequency (MAF)>5% in dominant hereditary diseases were used as negative gold standard. The selected mutations were predicted with the five software. Based on the results, the performance of the five software was evaluated for their sensitivity, specificity, positive predict value, false positive rate, negative predict value, false negative rate, false discovery rate, accuracy, and receiver operating characteristic curve (ROC). In terms of sensitivity, negative predictive value and false negative rate, the rank was MutationTaster, PolyPhen2, Provean, SIFT, and MutationAssessor. For specificity and false positive rate, the rank was MutationTaster, Provean, MutationAssessor, SIFT, and PolyPhen2. For positive predict value and false discovery rate, the rank was MutationTaster, Provean, MutationAssessor, PolyPhen2, and SIFT. For area under the ROC curve (AUC) and accuracy, the rank was MutationTaster, Provean, PolyPhen2, MutationAssessor, and SIFT. The prediction performance of software may be different when using different parameters. Among the five software, MutationTaster has the best prediction performance.

  5. Detection of Extended-Spectrum β-Lactamases in Clinical Isolates of Enterobacter cloacae and Enterobacter aerogenes

    PubMed Central

    Tzelepi, Eva; Giakkoupi, Panagiota; Sofianou, Danai; Loukova, Veneta; Kemeroglou, Anastassia; Tsakris, Athanassios

    2000-01-01

    The aim of the present study was to investigate the frequency of extended-spectrum β-lactamases (ESBLs) in a consecutive collection of clinical isolates of Enterobacter spp. The abilities of various screening methods to detect ESBLs in enterobacters were simultaneously tested. Among the 68 consecutive isolates (56 Enterobacter cloacae and 12 Enterobacter aerogenes isolates) that were analyzed for β-lactamase content, 21 (25 and 58%, respectively) possessed transferable ESBLs with pIs of 8.2 and phenotypic characteristics of SHV-type enzymes, 8 (14.3%) of the E. cloacae isolates produced a previously nondescribed, clavulanate-susceptible ESBL that exhibited a pI of 6.9 and that conferred a ceftazidime resistance phenotype on Escherichia coli transconjugants, and 2 E. cloacae isolates produced both of these enzymes. Among the total of 31 isolates that were considered ESBL producers, the Vitek ESBL detection test was positive for 2 (6.5%) strains, and the conventional double-disk synergy test (DDST) with amoxicillin-clavulanate and with expanded-spectrum cephalosporins and aztreonam was positive for 5 (16%) strains. Modifications of the DDST consisting of closer application of the disks (at 20 instead of 30 mm), the use of cefepime, and the use of both modifications increased the sensitivity of this test to 71, 61, and 90%, respectively. Of the 37 isolates for which isoelectric focusing failed to determine ESBLs, the Vitek test was false positive for 1 isolate and the various forms of DDSTs were false-positive for 3 isolates. PMID:10655342

  6. Efficient detection of human circulating tumor cells without significant production of false-positive cells by a novel conditionally replicating adenovirus

    PubMed Central

    Sakurai, Fuminori; Narii, Nobuhiro; Tomita, Kyoko; Togo, Shinsaku; Takahashi, Kazuhisa; Machitani, Mitsuhiro; Tachibana, Masashi; Ouchi, Masaaki; Katagiri, Nobuyoshi; Urata, Yasuo; Fujiwara, Toshiyoshi; Mizuguchi, Hiroyuki

    2016-01-01

    Circulating tumor cells (CTCs) are promising biomarkers in several cancers, and thus methods and apparatuses for their detection and quantification in the blood have been actively pursued. A novel CTC detection system using a green fluorescence protein (GFP)–expressing conditionally replicating adenovirus (Ad) (rAd-GFP) was recently developed; however, there is concern about the production of false-positive cells (GFP-positive normal blood cells) when using rAd-GFP, particularly at high titers. In addition, CTCs lacking or expressing low levels of coxsackievirus–adenovirus receptor (CAR) cannot be detected by rAd-GFP, because rAd-GFP is constructed based on Ad serotype 5, which recognizes CAR. In order to suppress the production of false-positive cells, sequences perfectly complementary to blood cell–specific microRNA, miR-142-3p, were incorporated into the 3′-untranslated region of the E1B and GFP genes. In addition, the fiber protein was replaced with that of Ad serotype 35, which recognizes human CD46, creating rAdF35-142T-GFP. rAdF35-142T-GFP efficiently labeled not only CAR-positive tumor cells but also CAR-negative tumor cells with GFP. The numbers of false-positive cells were dramatically lower for rAdF35-142T-GFP than for rAd-GFP. CTCs in the blood of cancer patients were detected by rAdF35-142T-GFP with a large reduction in false-positive cells. PMID:26966699

  7. Distinguishing Binders from False Positives by Free Energy Calculations: Fragment Screening Against the Flap Site of HIV Protease

    PubMed Central

    2015-01-01

    Molecular docking is a powerful tool used in drug discovery and structural biology for predicting the structures of ligand–receptor complexes. However, the accuracy of docking calculations can be limited by factors such as the neglect of protein reorganization in the scoring function; as a result, ligand screening can produce a high rate of false positive hits. Although absolute binding free energy methods still have difficulty in accurately rank-ordering binders, we believe that they can be fruitfully employed to distinguish binders from nonbinders and reduce the false positive rate. Here we study a set of ligands that dock favorably to a newly discovered, potentially allosteric site on the flap of HIV-1 protease. Fragment binding to this site stabilizes a closed form of protease, which could be exploited for the design of allosteric inhibitors. Twenty-three top-ranked protein–ligand complexes from AutoDock were subject to the free energy screening using two methods, the recently developed binding energy analysis method (BEDAM) and the standard double decoupling method (DDM). Free energy calculations correctly identified most of the false positives (≥83%) and recovered all the confirmed binders. The results show a gap averaging ≥3.7 kcal/mol, separating the binders and the false positives. We present a formula that decomposes the binding free energy into contributions from the receptor conformational macrostates, which provides insights into the roles of different binding modes. Our binding free energy component analysis further suggests that improving the treatment for the desolvation penalty associated with the unfulfilled polar groups could reduce the rate of false positive hits in docking. The current study demonstrates that the combination of docking with free energy methods can be very useful for more accurate ligand screening against valuable drug targets. PMID:25189630

  8. Female False Positive Exercise Stress ECG Testing - Fact Verses Fiction.

    PubMed

    Fitzgerald, Benjamin T; Scalia, William M; Scalia, Gregory M

    2018-03-07

    Exercise stress testing is a well validated cardiovascular investigation. Accuracy for treadmill stress electrocardiograph (ECG) testing has been documented at 60%. False positive stress ECGs (exercise ECG changes with non-obstructive disease on anatomical testing) are common, especially in women, limiting the effectiveness of the test. This study investigates the incidence and predictors of false positive stress ECG findings, referenced against stress echocardiography (SE) as a standard. Stress echocardiography was performed using the Bruce treadmill protocol. False positive stress ECG tests were defined as greater than 1mm of ST depression on ECG during exertion, without pain, with a normal SE. Potential causes for false positive tests were recorded before the test. Three thousand consecutive negative stress echocardiograms (1036 females, 34.5%) were analysed (age 59+/-14 years. False positive (F+) stress ECGs were documented in 565/3000 tests (18.8%). F+ stress ECGs were equally prevalent in females (194/1036, 18.7%) and males (371/1964, 18.9%, p=0.85 for the difference). Potential causes (hypertension, left ventricular hypertrophy, known coronary disease, arrhythmia, diabetes mellitus, valvular heart disease) were recorded in 36/194 (18.6%) of the female F+ ECG tests and 249/371 (68.2%) of the male F+ ECG tests (p<0.0001 for the difference). These data suggest that F+ stress ECG tests are frequent and equally common in women and men. However, most F+ stress ECGs in men can be predicted before the test, while most in women cannot. Being female may be a risk factor in itself. These data reinforce the value of stress imaging, particularly in women. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  9. Critical Analysis of the Mathematical Formalism of Theoretical Physics. V. Foundations of the Theory of Negative Numbers

    NASA Astrophysics Data System (ADS)

    Kalanov, Temur Z.

    2015-04-01

    Analysis of the foundations of the theory of negative numbers is proposed. The unity of formal logic and of rational dialectics is methodological basis of the analysis. Statement of the problem is as follows. As is known, point O in the Cartesian coordinate system XOY determines the position of zero on the scale. The number ``zero'' belongs to both the scale of positive numbers and the scale of negative numbers. In this case, the following formallogical contradiction arises: the number 0 is both positive number and negative number; or, equivalently, the number 0 is neither positive number nor negative number, i.e. number 0 has no sign. Then the following question arises: Do negative numbers exist in science and practice? A detailed analysis of the problem shows that negative numbers do not exist because the foundations of the theory of negative numbers contrary to the formal-logical laws. It is proved that: (a) all numbers have no signs; (b) the concepts ``negative number'' and ``negative sign of number'' represent a formallogical error; (c) signs ``plus'' and ``minus'' are only symbols of mathematical operations. The logical errors determine the essence of the theory of negative numbers: the theory of negative number is a false theory.

  10. Reduction of false-positives in a CAD scheme for automated detection of architectural distortion in digital mammography

    NASA Astrophysics Data System (ADS)

    de Oliveira, Helder C. R.; Mencattini, Arianna; Casti, Paola; Martinelli, Eugenio; di Natale, Corrado; Catani, Juliana H.; de Barros, Nestor; Melo, Carlos F. E.; Gonzaga, Adilson; Vieira, Marcelo A. C.

    2018-02-01

    This paper proposes a method to reduce the number of false-positives (FP) in a computer-aided detection (CAD) scheme for automated detection of architectural distortion (AD) in digital mammography. AD is a subtle contraction of breast parenchyma that may represent an early sign of breast cancer. Due to its subtlety and variability, AD is more difficult to detect compared to microcalcifications and masses, and is commonly found in retrospective evaluations of false-negative mammograms. Several computer-based systems have been proposed for automated detection of AD in breast images. The usual approach is automatically detect possible sites of AD in a mammographic image (segmentation step) and then use a classifier to eliminate the false-positives and identify the suspicious regions (classification step). This paper focus on the optimization of the segmentation step to reduce the number of FPs that is used as input to the classifier. The proposal is to use statistical measurements to score the segmented regions and then apply a threshold to select a small quantity of regions that should be submitted to the classification step, improving the detection performance of a CAD scheme. We evaluated 12 image features to score and select suspicious regions of 74 clinical Full-Field Digital Mammography (FFDM). All images in this dataset contained at least one region with AD previously marked by an expert radiologist. The results showed that the proposed method can reduce the false positives of the segmentation step of the CAD scheme from 43.4 false positives (FP) per image to 34.5 FP per image, without increasing the number of false negatives.

  11. The local lymph node assay: current position in the regulatory classification of skin sensitizing chemicals.

    PubMed

    Basketter, David A; Gerberick, G Frank; Kimber, Ian

    2007-01-01

    The local lymph node assay (LLNA) is being used increasingly in the identification of skin sensitizing chemicals for regulatory purposes. In the context of new chemicals legislation (REACH) in Europe, it is the preferred assay. The rationale for this is that the LLNA quantitative and objective approach to skin sensitization testing allied with the important animal welfare benefits that the method offers. However, as with certain guinea pig sensitization tests before it, this increasing use also brings experience with an increasingly wide range of industrial and other chemicals where the outcome of the assay does not always necessarily meet with the expectations of those conducting it. Sometimes, the result appears to be a false negative, but rather more commonly, the complaint is that the chemical represents a false positive. Against this background we have here reviewed a number of instances where false positive and false negative results have been described and have sought to reconcile science with expectation. Based on these analyses, it is our conclusion that false positives and false negatives do occur in the LLNA, as they do with any other skin sensitization assay (and indeed with all tests used for hazard identification), and that this occurs for a number of reasons. We further conclude, however, that false positive results in the LLNA, as with the guinea pig maximization test, arise most commonly via failure to distinguish what is scientifically correct from that which is unpalatable. The consequences of this confusion are discussed in the article, particularly in relation to the need to integrate both potency measurement and risk assessments into classification and labelling schemes that aim to manage potential risks to human health.

  12. Unmodeled observation error induces bias when inferring patterns and dynamics of species occurrence via aural detections

    USGS Publications Warehouse

    McClintock, Brett T.; Bailey, Larissa L.; Pollock, Kenneth H.; Simons, Theodore R.

    2010-01-01

    The recent surge in the development and application of species occurrence models has been associated with an acknowledgment among ecologists that species are detected imperfectly due to observation error. Standard models now allow unbiased estimation of occupancy probability when false negative detections occur, but this is conditional on no false positive detections and sufficient incorporation of explanatory variables for the false negative detection process. These assumptions are likely reasonable in many circumstances, but there is mounting evidence that false positive errors and detection probability heterogeneity may be much more prevalent in studies relying on auditory cues for species detection (e.g., songbird or calling amphibian surveys). We used field survey data from a simulated calling anuran system of known occupancy state to investigate the biases induced by these errors in dynamic models of species occurrence. Despite the participation of expert observers in simplified field conditions, both false positive errors and site detection probability heterogeneity were extensive for most species in the survey. We found that even low levels of false positive errors, constituting as little as 1% of all detections, can cause severe overestimation of site occupancy, colonization, and local extinction probabilities. Further, unmodeled detection probability heterogeneity induced substantial underestimation of occupancy and overestimation of colonization and local extinction probabilities. Completely spurious relationships between species occurrence and explanatory variables were also found. Such misleading inferences would likely have deleterious implications for conservation and management programs. We contend that all forms of observation error, including false positive errors and heterogeneous detection probabilities, must be incorporated into the estimation framework to facilitate reliable inferences about occupancy and its associated vital rate parameters.

  13. Best research practices in psychology: Illustrating epistemological and pragmatic considerations with the case of relationship science.

    PubMed

    Finkel, Eli J; Eastwick, Paul W; Reis, Harry T

    2015-02-01

    In recent years, a robust movement has emerged within psychology to increase the evidentiary value of our science. This movement, which has analogs throughout the empirical sciences, is broad and diverse, but its primary emphasis has been on the reduction of statistical false positives. The present article addresses epistemological and pragmatic issues that we, as a field, must consider as we seek to maximize the scientific value of this movement. Regarding epistemology, this article contrasts the false-positives-reduction (FPR) approach with an alternative, the error balance (EB) approach, which argues that any serious consideration of optimal scientific practice must contend simultaneously with both false-positive and false-negative errors. Regarding pragmatics, the movement has devoted a great deal of attention to issues that frequently arise in laboratory experiments and one-shot survey studies, but it has devoted less attention to issues that frequently arise in intensive and/or longitudinal studies. We illustrate these epistemological and pragmatic considerations with the case of relationship science, one of the many research domains that frequently employ intensive and/or longitudinal methods. Specifically, we examine 6 research prescriptions that can help to reduce false-positive rates: preregistration, prepublication sharing of materials, postpublication sharing of data, close replication, avoiding piecemeal publication, and increasing sample size. For each, we offer concrete guidance not only regarding how researchers can improve their research practices and balance the risk of false-positive and false-negative errors, but also how the movement can capitalize upon insights from research practices within relationship science to make the movement stronger and more inclusive. PsycINFO Database Record (c) 2015 APA, all rights reserved.

  14. Newborn screening for cystic fibrosis in Wisconsin: comparison of biochemical and molecular methods.

    PubMed

    Gregg, R G; Simantel, A; Farrell, P M; Koscik, R; Kosorok, M R; Laxova, A; Laessig, R; Hoffman, G; Hassemer, D; Mischler, E H; Splaingard, M

    1997-06-01

    To evaluate neonatal screening for cystic fibrosis (CF), including study of the screening procedures and characteristics of false-positive infants, over the past 10 years in Wisconsin. An important objective evolving from the original design has been to compare use of a single-tier immunoreactive trypsinogen (IRT) screening method with that of a two-tier method using IRT and analyses of samples for the most common cystic fibrosis transmembrane regulator (CFTR) (DeltaF508) mutation. We also examined the benefit of including up to 10 additional CFTR mutations in the screening protocol. From 1985 to 1994, using either the IRT or IRT/DNA protocol, 220 862 and 104 308 neonates, respectively, were screened for CF. For the IRT protocol, neonates with an IRT >/=180 ng/mL were considered positive, and the standard sweat chloride test was administered to determine CF status. For the IRT/DNA protocol, samples from the original dried-blood specimen on the Guthrie card of neonates with an IRT >/=110 ng/mL were tested for the presence of the DeltaF508 CFTR allele, and if the DNA test revealed one or two DeltaF508 alleles, a sweat test was obtained. Both screening procedures had very high specificity. The sensitivity tended to be higher with the IRT/DNA protocol, but the differences were not statistically significant. The positive predictive value of the IRT/DNA screening protocol was 15.2% compared with 6.4% if the same samples had been screened by the IRT method. Assessment of the false-positive IRT/DNA population revealed that the two-tier method eliminates the disproportionate number of infants with low Apgar scores and also the high prevalence of African-Americans identified previously in our study of newborns with high IRT levels. We found that 55% of DNA-positive CF infants were homozygous for DeltaF508 and 40% had one DeltaF508 allele. Adding analyses for 10 more CFTR mutations has only a small effect on the sensitivity but is likely to add significantly to the cost of screening. Advantages of the IRT/DNA protocol over IRT analysis include improved positive predictive value, reduction of false-positive infants, and more rapid diagnosis with elimination of recall specimens.

  15. Are the memories of older adults positively biased?

    PubMed

    Fernandes, Myra; Ross, Michael; Wiegand, Melanie; Schryer, Emily

    2008-06-01

    There is disagreement in the literature about whether a "positivity effect" in memory performance exists in older adults. To assess the generalizability of the effect, the authors examined memory for autobiographical, picture, and word information in a group of younger (17-29 years old) and older (60-84 years old) adults. For the autobiographical memory task, the authors asked participants to produce 4 positive, 4 negative, and 4 neutral recent autobiographical memories and to recall these a week later. For the picture and word tasks, participants studied photos or words of different valences (positive, negative, neutral) and later remembered them on a free-recall test. The authors found significant correlations in memory performance, across task material, for recall of both positive and neutral valence autobiographical events, pictures, and words. When the authors examined accurate memories, they failed to find consistent evidence, across the different types of material, of a positivity effect in either age group. However, the false memory findings offer more consistent support for a positivity effect in older adults. During recall of all 3 types of material, older participants recalled more false positive than false negative memories.

  16. Clinical sensitivity and specificity of the Check-Points Check-Direct ESBL Screen for BD MAX, a real-time PCR for direct ESBL detection from rectal swabs.

    PubMed

    Souverein, Dennis; Euser, Sjoerd M; van der Reijden, Wil A; Herpers, Bjorn L; Kluytmans, Jan; Rossen, John W A; Den Boer, Jeroen W

    2017-09-01

    To determine the diagnostic accuracy of the Check-Direct ESBL Screen for BD MAX (ESBL qPCR) and an ESBL culture method to identify ESBLs directly from rectal swabs. Rectal swabs were obtained from clinical patients by performing cross-sectional (point)prevalence measurements in three regional hospitals. Rectal swabs were analysed by direct culture (ChromID ESBL agar) and with the ESBL qPCR. Suspected ESBL-producing isolates were confirmed with the combination disc method and analysed by WGS. Out of 354 rectal swabs and 351 patients, 21 rectal swabs and 20 patients were positive for ESBL-producing isolates, resulting in a regional ESBL colonization prevalence of 5.7%. One rectal swab was false negative with the ESBL qPCR (blaTEM-12) and not covered by the ESBL qPCR. Eight ESBL qPCR-positive rectal swabs could not be confirmed by culture and were classified as false ESBL qPCR positive. The sensitivity and specificity of the ESBL qPCR were 95.2% (n = 20) and 97.6% (n = 323), respectively. When an optimal cycle threshold cut-off value of 37 was used, the ESBL qPCR displayed a sensitivity and specificity of 95.2% (n = 20) and 98.8% (n = 327), respectively (AUC = 0.975, 95% CI = 0.922-1). This ESBL qPCR offers rapid direct detection of the most prevalent ESBL types (blaCTX-M group and blaSHV group) from rectal swabs. The relatively high false-positive rate renders this test the most suitable as a screening test in high-prevalence regions or in an outbreak setting where a fast result is essential. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Differential diagnosis of solitary pulmonary nodules based on 99mTc-EDDA/HYNIC-TOC scintigraphy: the effect of tumour size on the optimal method of image assessment.

    PubMed

    Płachcińska, Anna; Mikołajczak, Renata; Kozak, Józef; Rzeszutek, Katarzyna; Kuśmierek, Jacek

    2006-09-01

    The aim of the study was to determine an optimal method for the evaluation of scintigrams obtained with (99m)Tc-EDDA/HYNIC-TOC for the purpose of differential diagnosis of solitary pulmonary nodules (SPNs) and to assess the diagnostic value of the method. Eighty-five patients (48 males and 37 females, mean age 57 years, range 34-78 years) were enrolled in the study. Patients underwent (99m)Tc-EDDA/HYNIC-TOC scintigraphy for the purpose of differential diagnosis of SPNs (size between 1 and 4 cm). Images of all patients were evaluated visually in a prospective manner. Positive scintigraphic results were found in 37 out of 40 (93%) patients with malignant SPNs including 34 out of 35 (97%) patients with primary lung carcinoma. Two remaining false negative cases turned out to be metastatic lesions of malignant melanoma and leiomyosarcoma. Among 45 benign tumours, negative results were obtained in 31 cases (69%) and positive results in 14. The accuracy of the method was 80%. Analysis of the results of the visual assessment of scintigrams revealed a significantly higher frequency of false positive results among larger nodules (diameter at least 1.4 cm). Uptake of the tracer in those nodules was therefore assessed semi-quantitatively (using the tumour-to-background ratio), in expectation of an improvement in the low specificity of the visual method. The semi-quantitative assessment reduced the total number of false positive results in a subgroup of larger nodules from 13 to six, while preserving the high sensitivity of the method. The combination of visual analysis (for lesions smaller than 1.4 cm in diameter) and semi-quantitative assessment (for larger lesions) provided a high sensitivity of the method and significantly improved its specificity (84%) and accuracy (88%) in comparison with visual analysis (p<0.05).

  18. An analysis of whether surgeon-performed neck ultrasound can be used as the main localizing study in primary hyperparathyroidism.

    PubMed

    Aliyev, Shamil; Agcaoglu, Orhan; Aksoy, Erol; Birsen, Onur; Milas, Mira; Mitchell, Jamie; Siperstein, Allan; Berber, Eren

    2014-11-01

    Tc-99 sestamibi (MIBI) scan is the imaging study most frequently used in primary hyperparathyroidism (PHP). Transcutaneous cervical ultrasonography (US) is the other modality used for preoperative localization. The aim of this study was to determine whether surgeon-performed neck US can be used as the primary localizing study in PHP. This was a prospective study of 1,000 consecutive patients with first-time, sporadic PHP who underwent parathyroidectomy at a tertiary academic center. All patients had surgeon-performed neck US and MIBI before bilateral neck exploration. The findings at exploration were 72% single adenoma, 15% double adenoma, and 13% hyperplasia. When US suggested single-gland disease (n = 842), MIBI was concordant in 82.5%, discordant and false in 8%, negative in 7%, and discordant but correct in 2.5%. When US suggested multigland disease (n = 68), MIBI was concordant in 47%, discordant and false in 41%, and negative in 12%. When US was negative (n = 90), MIBI was positive and correct in 43%, negative in 31%, and positive but false in 26%. Surgeon-performed neck US identified unrecognized thyroid nodules in 326 patients (33%), which led to fine-needle aspiration biopsy in 161 (49%) patients and thyroid surgery in 103 (32%) patients, with a final diagnosis of thyroid cancer in 24 (7%) patients. Our results show that MIBI provides additional useful information in only a minority of patients with a positive US in PHP. Nevertheless, MIBI benefits about half of patients with a negative US. Because one-third of this patient population has unrecognized thyroid nodules as well, we propose that the most cost-effective algorithm would be to do US first and reserve MIBI for US-negative cases. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Fetal sex chromosome testing by maternal plasma DNA sequencing: clinical laboratory experience and biology.

    PubMed

    Bianchi, Diana W; Parsa, Saba; Bhatt, Sucheta; Halks-Miller, Meredith; Kurtzman, Kathryn; Sehnert, Amy J; Swanson, Amy

    2015-02-01

    To describe the clinical experience with noninvasive prenatal testing for fetal sex chromosomes using sequencing of maternal plasma cell-free DNA in a commercial laboratory. A noninvasive prenatal testing laboratory data set was examined for samples in which fetal sex chromosomes were reported. Available clinical outcomes were reviewed. Of 18,161 samples with sex chromosome results, no sex chromosome aneuploidy was detected in 98.9% and the fetal sex was reported as XY (9,236) or XX (8,721). In 4 of 32 cases in which the fetal sex was reportedly discordant between noninvasive prenatal testing and karyotype or ultrasonogram, a potential biological reason for the discordance exists, including two cases of documented co-twin demise, one case of a maternal kidney transplant from a male donor, and one case of fetal ambiguous genitalia. In the remaining 204 samples (1.1%), one of four sex chromosome aneuploidies (monosomy X, XXX, XXY, or XYY) was detected. The frequency of false positive results for sex chromosome aneuploidies is a minimum of 0.26% and a maximum of 1.05%. All but one of the discordant sex chromosome aneuploidy results involved the X chromosome. In two putative false-positive XXX cases, maternal XXX was confirmed by karyotype. For the false-positive cases, mean maternal age was significantly higher in monosomy X (P<.001) and lower in XXX (P=.008). Noninvasive prenatal testing results for sex chromosome aneuploidy can be confounded by maternal or fetal biological phenomena. When a discordant noninvasive prenatal testing result is encountered, resolution requires additional maternal history, detailed fetal ultrasonography, and determination of fetal and possibly maternal karyotypes.

  20. Local connected fractal dimension analysis in gill of fish experimentally exposed to toxicants.

    PubMed

    Manera, Maurizio; Giari, Luisa; De Pasquale, Joseph A; Sayyaf Dezfuli, Bahram

    2016-06-01

    An operator-neutral method was implemented to objectively assess European seabass, Dicentrarchus labrax (Linnaeus, 1758) gill pathology after experimental exposure to cadmium (Cd) and terbuthylazine (TBA) for 24 and 48h. An algorithm-derived local connected fractal dimension (LCFD) frequency measure was used in this comparative analysis. Canonical variates (CVA) and linear discriminant analysis (LDA) were used to evaluate the discrimination power of the method among exposure classes (unexposed, Cd exposed, TBA exposed). Misclassification, sensitivity and specificity, both with original and cross-validated cases, were determined. LCFDs frequencies enhanced the differences among classes which were visually selected after their means, respective variances and the differences between Cd and TBA exposed means, with respect to unexposed mean, were analyzed by scatter plots. Selected frequencies were then scanned by means of LDA, stepwise analysis, and Mahalanobis distance to detect the most discriminative frequencies out of ten originally selected. Discrimination resulted in 91.7% of cross-validated cases correctly classified (22 out of 24 total cases), with sensitivity and specificity, respectively, of 95.5% (1 false negative with respect to 21 really positive cases) and 75% (1 false positive with respect to 3 really negative cases). CVA with convex hull polygons ensured prompt, visually intuitive discrimination among exposure classes and graphically supported the false positive case. The combined use of semithin sections, which enhanced the visual evaluation of the overall lamellar structure; of LCFD analysis, which objectively detected local variation in complexity, without the possible bias connected to human personnel; and of CVA/LDA, could be an objective, sensitive and specific approach to study fish gill lamellar pathology. Furthermore this approach enabled discrimination with sufficient confidence between exposure classes or pathological states and avoided misdiagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Sensitivity and Specificity of Interictal EEG-fMRI for Detecting the Ictal Onset Zone at Different Statistical Thresholds

    PubMed Central

    Tousseyn, Simon; Dupont, Patrick; Goffin, Karolien; Sunaert, Stefan; Van Paesschen, Wim

    2014-01-01

    There is currently a lack of knowledge about electroencephalography (EEG)-functional magnetic resonance imaging (fMRI) specificity. Our aim was to define sensitivity and specificity of blood oxygen level dependent (BOLD) responses to interictal epileptic spikes during EEG-fMRI for detecting the ictal onset zone (IOZ). We studied 21 refractory focal epilepsy patients who had a well-defined IOZ after a full presurgical evaluation and interictal spikes during EEG-fMRI. Areas of spike-related BOLD changes overlapping the IOZ in patients were considered as true positives; if no overlap was found, they were treated as false-negatives. Matched healthy case-controls had undergone similar EEG-fMRI in order to determine true-negative and false-positive fractions. The spike-related regressor of the patient was used in the design matrix of the healthy case-control. Suprathreshold BOLD changes in the brain of controls were considered as false positives, absence of these changes as true negatives. Sensitivity and specificity were calculated for different statistical thresholds at the voxel level combined with different cluster size thresholds and represented in receiver operating characteristic (ROC)-curves. Additionally, we calculated the ROC-curves based on the cluster containing the maximal significant activation. We achieved a combination of 100% specificity and 62% sensitivity, using a Z-threshold in the interval 3.4–3.5 and cluster size threshold of 350 voxels. We could obtain higher sensitivity at the expense of specificity. Similar performance was found when using the cluster containing the maximal significant activation. Our data provide a guideline for different EEG-fMRI settings with their respective sensitivity and specificity for detecting the IOZ. The unique cluster containing the maximal significant BOLD activation was a sensitive and specific marker of the IOZ. PMID:25101049

  2. A randomized and blinded comparison of qPCR and NGS-based detection of aneuploidy in a cell line mixture model of blastocyst biopsy mosaicism.

    PubMed

    Goodrich, David; Tao, Xin; Bohrer, Chelsea; Lonczak, Agnieszka; Xing, Tongji; Zimmerman, Rebekah; Zhan, Yiping; Scott, Richard T; Treff, Nathan R

    2016-11-01

    A subset of preimplantation stage embryos may possess mosaicism of chromosomal constitution, representing a possible limitation to the clinical predictive value of comprehensive chromosome screening (CCS) from a single biopsy. However, contemporary methods of CCS may be capable of predicting mosaicism in the blastocyst by detecting intermediate levels of aneuploidy within a trophectoderm biopsy. This study evaluates the sensitivity and specificity of aneuploidy detection by two CCS platforms using a cell line mixture model of a mosaic trophectoderm biopsy. Four cell lines with known karyotypes were obtained and mixed together at specific ratios of six total cells (0:6, 1:5, 2:4, 3:3, 4:2, 5:1, and 6:0). A female euploid and a male trisomy 18 cell line were used for one set, and a male trisomy 13 and a male trisomy 15 cell line were used for another. Replicates of each mixture were prepared, randomized, and blinded for analysis by one of two CCS platforms (quantitative polymerase chain reaction (qPCR) or VeriSeq next-generation sequencing (NGS)). Sensitivity and specificity of aneuploidy detection at each level of mosaicism was determined and compared between platforms. With the default settings for each platform, the sensitivity of qPCR and NGS were not statistically different, and 100 % specificity was observed (no false positives) at all levels of mosaicism. However, the use of previously published custom criteria for NGS increased sensitivity but also significantly decreased specificity (33 % false-positive prediction of aneuploidy). By demonstrating increased false-positive diagnoses when reducing the stringency of predicting an abnormality, these data illustrate the importance of preclinical evaluation of new testing paradigms before clinical implementation.

  3. Minimising Immunohistochemical False Negative ER Classification Using a Complementary 23 Gene Expression Signature of ER Status

    PubMed Central

    Li, Qiyuan; Eklund, Aron C.; Juul, Nicolai; Haibe-Kains, Benjamin; Workman, Christopher T.; Richardson, Andrea L.; Szallasi, Zoltan; Swanton, Charles

    2010-01-01

    Background Expression of the oestrogen receptor (ER) in breast cancer predicts benefit from endocrine therapy. Minimising the frequency of false negative ER status classification is essential to identify all patients with ER positive breast cancers who should be offered endocrine therapies in order to improve clinical outcome. In routine oncological practice ER status is determined by semi-quantitative methods such as immunohistochemistry (IHC) or other immunoassays in which the ER expression level is compared to an empirical threshold[1], [2]. The clinical relevance of gene expression-based ER subtypes as compared to IHC-based determination has not been systematically evaluated. Here we attempt to reduce the frequency of false negative ER status classification using two gene expression approaches and compare these methods to IHC based ER status in terms of predictive and prognostic concordance with clinical outcome. Methodology/Principal Findings Firstly, ER status was discriminated by fitting the bimodal expression of ESR1 to a mixed Gaussian model. The discriminative power of ESR1 suggested bimodal expression as an efficient way to stratify breast cancer; therefore we identified a set of genes whose expression was both strongly bimodal, mimicking ESR expression status, and highly expressed in breast epithelial cell lines, to derive a 23-gene ER expression signature-based classifier. We assessed our classifiers in seven published breast cancer cohorts by comparing the gene expression-based ER status to IHC-based ER status as a predictor of clinical outcome in both untreated and tamoxifen treated cohorts. In untreated breast cancer cohorts, the 23 gene signature-based ER status provided significantly improved prognostic power compared to IHC-based ER status (P = 0.006). In tamoxifen-treated cohorts, the 23 gene ER expression signature predicted clinical outcome (HR = 2.20, P = 0.00035). These complementary ER signature-based strategies estimated that between 15.1% and 21.8% patients of IHC-based negative ER status would be classified with ER positive breast cancer. Conclusion/Significance Expression-based ER status classification may complement IHC to minimise false negative ER status classification and optimise patient stratification for endocrine therapies. PMID:21152022

  4. Accuracy of administrative data versus clinical data to evaluate carotid endarterectomy and carotid stenting.

    PubMed

    Bensley, Rodney P; Yoshida, Shunsuke; Lo, Ruby C; Fokkema, Margriet; Hamdan, Allen D; Wyers, Mark C; Chaikof, Elliot L; Schermerhorn, Marc L

    2013-08-01

    Administrative data have been used to compare carotid endarterectomy (CEA) and carotid artery stenting (CAS). However, there are limitations in defining symptom status, Centers for Medicare and Medicaid Services high-risk status, as well as complications. Therefore, we did a direct comparison between administrative data and physician chart review as well as between data collected for the National Surgical Quality Improvement Program (NSQIP) and physician chart review for CEA and CAS. We performed an outcomes analysis on all CEA and CAS procedures from 2005 to 2011. We obtained International Classification of Diseases, Ninth Revision diagnosis codes from hospital discharge records regarding symptom status, high-risk status, and perioperative stroke. We also obtained data on all CEA patients submitted to NSQIP over the same time period. One of the study authors (R.B.) then performed a chart review of the same patients to determine symptom status, high-risk status, and perioperative strokes and the results were compared. We identified 1342 patients who underwent CEA or CAS between 2005 and 2011 and 392 patients who underwent CEA that were submitted to NSQIP. Administrative data identified fewer symptomatic patients (17.0% vs 34.0%), physiologic high-risk patients (9.3% vs 23.0%), and anatomic high-risk patients (0% vs 15.2%). Although administrative data identified a similar proportion of perioperative strokes (1.9% vs 2.0%), this was due to the fact that these data identified eight false positive and nine false negative perioperative strokes. NSQIP data identified more symptomatic patients compared with chart review (44.1% vs 30.3%), fewer physiologic high-risk patients (13.0% vs 18.6%), fewer anatomic high-risk patients (0% vs 6.6%), and a similar proportion of perioperative strokes (1.5% vs 1.8%, only one false negative stroke and no false positives). Administrative data are unreliable for determining symptom status, high-risk status, and perioperative stroke and should not be used to analyze CEA and CAS. NSQIP data do not adequately identify high-risk patients, but do accurately identify perioperative strokes and to a lesser degree, symptom status. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  5. Standoff detection of chemical and biological threats using laser-induced breakdown spectroscopy.

    PubMed

    Gottfried, Jennifer L; De Lucia, Frank C; Munson, Chase A; Miziolek, Andrzej W

    2008-04-01

    Laser-induced breakdown spectroscopy (LIBS) is a promising technique for real-time chemical and biological warfare agent detection in the field. We have demonstrated the detection and discrimination of the biological warfare agent surrogates Bacillus subtilis (BG) (2% false negatives, 0% false positives) and ovalbumin (0% false negatives, 1% false positives) at 20 meters using standoff laser-induced breakdown spectroscopy (ST-LIBS) and linear correlation. Unknown interferent samples (not included in the model), samples on different substrates, and mixtures of BG and Arizona road dust have been classified with reasonable success using partial least squares discriminant analysis (PLS-DA). A few of the samples tested such as the soot (not included in the model) and the 25% BG:75% dust mixture resulted in a significant number of false positives or false negatives, respectively. Our preliminary results indicate that while LIBS is able to discriminate biomaterials with similar elemental compositions at standoff distances based on differences in key intensity ratios, further work is needed to reduce the number of false positives/negatives by refining the PLS-DA model to include a sufficient range of material classes and carefully selecting a detection threshold. In addition, we have demonstrated that LIBS can distinguish five different organophosphate nerve agent simulants at 20 meters, despite their similar stoichiometric formulas. Finally, a combined PLS-DA model for chemical, biological, and explosives detection using a single ST-LIBS sensor has been developed in order to demonstrate the potential of standoff LIBS for universal hazardous materials detection.

  6. X-Ray Phantom Development For Observer Performance Studies

    NASA Astrophysics Data System (ADS)

    Kelsey, C. A.; Moseley, R. D.; Mettler, F. A.; Parker, T. W.

    1981-07-01

    The requirements for radiographic imaging phantoms for observer performance testing include realistic tasks which mimic at least some portion of the diagnostic examination presented in a setting which approximates clinically derived images. This study describes efforts to simulate chest and vascular diseases for evaluation of conventional and digital radiographic systems. Images of lung nodules, pulmonary infiltrates, as well as hilar and mediastinal masses are generated with a conventional chest phantom to make up chest disease test series. Vascular images are simulated by hollow tubes embedded in tissue density plastic with widening and narrowing added to mimic aneurysms and stenoses. Both sets of phantoms produce images which allow simultaneous determination of true positive and false positive rates as well as complete ROC curves.

  7. Hormone replacement therapy and false positive recall in the Million Women Study: patterns of use, hormonal constituents and consistency of effect

    PubMed Central

    Banks, Emily; Reeves, Gillian; Beral, Valerie; Bull, Diana; Crossley, Barbara; Simmonds, Moya; Hilton, Elizabeth; Bailey, Stephen; Barrett, Nigel; Briers, Peter; English, Ruth; Jackson, Alan; Kutt, Elizabeth; Lavelle, Janet; Rockall, Linda; Wallis, Matthew G; Wilson, Mary; Patnick, Julietta

    2006-01-01

    Introduction Current and recent users of hormone replacement therapy (HRT) have an increased risk of being recalled to assessment at mammography without breast cancer being diagnosed ('false positive recall'), but there is limited information on the effects of different patterns of HRT use on this. The aim of this study is to investigate in detail the relationship between patterns of use of HRT and false positive recall. Methods A total of 87,967 postmenopausal women aged 50 to 64 years attending routine breast cancer screening at 10 UK National Health Service Breast Screening Units from 1996 to 1998 joined the Million Women Study by completing a questionnaire before screening and were followed for their screening outcome. Results Overall, 399 (0.5%) participants were diagnosed with breast cancer and 2,629 (3.0%) had false positive recall. Compared to never users of HRT, the adjusted relative risk (95% CI) of false positive recall was: 1.62 (1.43–1.83), 1.80 (1.62–2.01) and 0.76 (0.52–1.10) in current users of oestrogen-only HRT, oestrogen-progestagen HRT and tibolone, respectively (p (heterogeneity) < 0.0001); 1.65 (1.43–1.91), 1.49 (1.22–1.81) and 2.11 (1.45–3.07) for current HRT used orally, transdermally or via an implant, respectively (p (heterogeneity) = 0.2); and 1.84 (1.67–2.04) and 1.75 (1.49–2.06) for sequential and continuous oestrogen-progestagen HRT, respectively (p (heterogeneity) = 0.6). The relative risk of false positive recall among current users appeared to increase with increasing time since menopause, but did not vary significantly according to any other factors examined, including duration of use, hormonal constituents, dose, whether single- or two-view screening was used, or the woman's personal characteristics. Conclusion Current use of oestrogen-only and oestrogen-progestagen HRT, but not tibolone, increases the risk of false positive recall at screening. PMID:16417651

  8. Hemoglobin mass and biological passport for the detection of autologous blood doping.

    PubMed

    Pottgiesser, Torben; Echteler, Tobias; Sottas, Pierre-Edouard; Umhau, Markus; Schumacher, Yorck Olaf

    2012-05-01

    The most promising attempt to reveal otherwise undetectable autologous blood doping is the Athlete Biological Passport enabling a longitudinal monitoring of hematological measures. Recently, the determination of hemoglobin mass (tHb) was suggested to be incorporated in the adaptive model of the Athlete Biological Passport. The purpose therefore was to evaluate the performance of tHb as part of the adaptive model for the detection of autologous blood transfusions in a longitudinal blinded study. Twenty-one subjects were divided into a doped group (n = 11) and a control group (n = 10). During the time course of a simulated cycling season (42 wk) including three major competitions (Classics, Grand Tour, World Championships), multiple autologous transfusions of erythrocyte concentrates were assigned in the doped group. A blinded investigator ordered up to 10 tHb measurements (carbon monoxide rebreathing) per subject, mimicking an intelligent doping testing approach in obtaining hematological data (tHb, OFFmass (novel marker including reticulocytes), and respective sequences) for the adaptive model. The final analysis included 199 of 206 overall tHb measurements. The use of tHb, OFFmass, and their sequences as markers of the adaptive model at the 99% specificity level allowed identification of 10 of 11 doped subjects (91% sensitivity) including one false positive in the control group. At the 99.9% specificity level, 8 of 11 subjects were identified without false positives (73% sensitivity). It seems that the problems of tHb determination by carbon monoxide rebreathing limit the application of this method in antidoping. Because of its potential to detect individual abnormalities associated with autologous blood transfusions shown in this study, a method for tHb determination that is compatible with today's standards of testing should be the focus of future research.

  9. False-positive cerebrospinal fluid cryptococcus antigen in Libman-Sacks endocarditis.

    PubMed

    Isseh, Iyad N; Bourgi, Kassem; Nakhle, Asaad; Ali, Mahmoud; Zervos, Marcus J

    2016-12-01

    Cryptococcus meningoencephalitis is a serious opportunistic infection associated with high morbidity and mortality in immunocompromised hosts, particularly patients with advanced AIDS disease. The diagnosis is established through cerebrospinal fluid (CSF) cryptococcus antigen detection and cultures. Cryptococcus antigen testing is usually the initial test of choice due its high sensitivity and specificity along with the quick availability of the results. We hereby report a case of a false-positive CSF cryptococcus antigen assay in a patient with systemic lupus erythematosus presenting with acute confusion. While initial CSF evaluation revealed a positive cryptococcus antigen assay, the patient's symptoms were inconsistent with cryptococcus meningoencephalitis. A repeat CSF evaluation, done 3 days later, revealed a negative CSF cryptococcus antigen assay. Given the patient's active lupus disease and the elevated antinuclear antibody titers, we believe that the initial positive result was a false positive caused by interference from autoantibodies.

  10. Silastic injection for vocal fold medialization resulting in a false-positive finding on F18 FDG-PET/CT.

    PubMed

    Mahfouz, Ayman; Naji, Meeran; Mok, Wing Yan; Taghi, Ali S; Win, Zarni

    2015-09-01

    A false-positive uptake of F18-fluorodeoxyglucose (FDG) on positron-emission tomography/computed tomography (PET/CT) can result in confusion and misinterpretation of scans. Such uptakes have been previously described after injection of polytetrafluoroethylene (Teflon) into the vocal folds. Similarly, vocal fold injection of silicone elastomer (Silastic) can result not only in a false-positive FDG uptake on PET/CT, but also in chronic inflammation. We report a case of increased FDG uptake in a vocal fold after Silastic injection that was misinterpreted as a malignancy in a 70-year-old woman who had metastatic carcinoma of the stomach.

  11. HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites

    PubMed Central

    Kosack, Cara S.; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng’ang’a, Anne; Andre, Bita; Zahinda, Jean-Paul BN; Fransen, Katrien; Page, Anne-Laure

    2017-01-01

    Abstract Introduction: We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. Methods: In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Results: Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. Conclusions: The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy. PMID:28691437

  12. HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites.

    PubMed

    Kosack, Cara S; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng'ang'a, Anne; Andre, Bita; Zahinda, Jean-Paul Bn; Fransen, Katrien; Page, Anne-Laure

    2017-07-03

    We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy.

  13. Evaluation of Raman spectroscopy in comparison to commonly performed dengue diagnostic tests

    NASA Astrophysics Data System (ADS)

    Khan, Saranjam; Ullah, Rahat; Khurram, Muhammad; Ali, Hina; Mahmood, Arshad; Khan, Ajmal; Ahmed, Mushtaq

    2016-09-01

    This study demonstrates the evaluation of Raman spectroscopy as a rapid diagnostic test in comparison to commonly performed tests for an accurate detection of dengue fever in human blood sera. Blood samples of 104 suspected dengue patients collected from Holy Family Hospital, Rawalpindi, Pakistan, have been used in this study. Out of 104 samples, 52 (50%) were positive based on immunoglobulin G (IgG), whereas 54 (52%) were positive based on immunoglobulin M (IgM) antibody tests. For the determination of the diagnostic capabilities of Raman spectroscopy, accuracy, sensitivity, specificity and false positive rate have been calculated in comparison to normally performed IgM and IgG captured enzyme-linked immunosorbent assay tests. Accuracy, precision, specificity, and sensitivity for Raman spectroscopy in comparison to IgM were found to be 66%, 70%, 72%, and 61%, whereas based on IgG they were 47%, 46%, 52%, and 43%, respectively.

  14. Progress toward the determination of correct classification rates in fire debris analysis.

    PubMed

    Waddell, Erin E; Song, Emma T; Rinke, Caitlin N; Williams, Mary R; Sigman, Michael E

    2013-07-01

    Principal components analysis (PCA), linear discriminant analysis (LDA), and quadratic discriminant analysis (QDA) were used to develop a multistep classification procedure for determining the presence of ignitable liquid residue in fire debris and assigning any ignitable liquid residue present into the classes defined under the American Society for Testing and Materials (ASTM) E 1618-10 standard method. A multistep classification procedure was tested by cross-validation based on model data sets comprised of the time-averaged mass spectra (also referred to as total ion spectra) of commercial ignitable liquids and pyrolysis products from common building materials and household furnishings (referred to simply as substrates). Fire debris samples from laboratory-scale and field test burns were also used to test the model. The optimal model's true-positive rate was 81.3% for cross-validation samples and 70.9% for fire debris samples. The false-positive rate was 9.9% for cross-validation samples and 8.9% for fire debris samples. © 2013 American Academy of Forensic Sciences.

  15. How does negative emotion cause false memories?

    PubMed

    Brainerd, C J; Stein, L M; Silveira, R A; Rohenkohl, G; Reyna, V F

    2008-09-01

    Remembering negative events can stimulate high levels of false memory, relative to remembering neutral events. In experiments in which the emotional valence of encoded materials was manipulated with their arousal levels controlled, valence produced a continuum of memory falsification. Falsification was highest for negative materials, intermediate for neutral materials, and lowest for positive materials. Conjoint-recognition analysis produced a simple process-level explanation: As one progresses from positive to neutral to negative valence, false memory increases because (a) the perceived meaning resemblance between false and true items increases and (b) subjects are less able to use verbatim memories of true items to suppress errors.

  16. Amplitude/frequency differences in a supine resting single-lead electrocardiogram of normal versus coronary heart diseased males.

    DOT National Transportation Integrated Search

    1974-05-01

    A resting 'normal' ECG can coexist with known angina pectoris, positive angiocardiography and previous myocardial infarction. In contemporary exercise ECG tests, a false positive/false negative total error of 10% is not unusual. Research aimed at imp...

  17. Finkelstein's test: a descriptive error that can produce a false positive.

    PubMed

    Elliott, B G

    1992-08-01

    Over the last three decades an error in performing Finkelstein's test has crept into the English literature in both text books and journals. This error can produce a false-positive, and if relied upon, a wrong diagnosis can be made, leading to inappropriate surgery.

  18. A Demonstration of Regression False Positive Selection in Data Mining

    ERIC Educational Resources Information Center

    Pinder, Jonathan P.

    2014-01-01

    Business analytics courses, such as marketing research, data mining, forecasting, and advanced financial modeling, have substantial predictive modeling components. The predictive modeling in these courses requires students to estimate and test many linear regressions. As a result, false positive variable selection ("type I errors") is…

  19. SU-F-T-235: Optical Scan Based Collision Avoidance Using Multiple Stereotactic Cameras During Simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cardan, R; Popple, R; Dobelbower, M

    Purpose: To demonstrate the ability to quickly generate an accurate collision avoidance map using multiple stereotactic cameras during simulation. Methods: Three Kinect stereotactic cameras were placed in the CT simulation room and optically calibrated to the DICOM isocenter. Immediately before scanning, the patient was optically imaged to generate a 3D polygon mesh, which was used to calculate the collision avoidance area using our previously developed framework. The mesh was visually compared to the CT scan body contour to ensure accurate coordinate alignment. To test the accuracy of the collision calculation, the patient and machine were physically maneuvered in the treatmentmore » room to calculated collision boundaries. Results: The optical scan and collision calculation took 38.0 seconds and 2.5 seconds to complete respectively. The collision prediction accuracy was determined using a receiver operating curve (ROC) analysis, where the true positive, true negative, false positive and false negative values were 837, 821, 43, and 79 points respectively. The ROC accuracy was 93.1% over the sampled collision space. Conclusion: We have demonstrated a framework which is fast and accurate for predicting collision avoidance for treatment which can be determined during the normal simulation process. Because of the speed, the system could be used to add a layer of safety with a negligible impact on the normal patient simulation experience. This information could be used during treatment planning to explore the feasible geometries when optimizing plans. Research supported by Varian Medical Systems.« less

  20. Measuring the psychosocial consequences of screening

    PubMed Central

    Brodersen, John; McKenna, Stephen P; Doward, Lynda C; Thorsen, Hanne

    2007-01-01

    The last three decades have seen a dramatic rise in the implementation of screening programmes for cancer in industrialised countries. However, in contrast to screening for infectious diseases, most cancer screening programmes only have the potential to reduce mortality; they cannot lower the incidence of cancer in a population. In fact, most cancer screening programmes have been shown to increase the incidence of the disease as a consequence of over-diagnosis. A further dilemma of cancer screening programmes is that they do not distinguish between healthy people and those with disease. Rather, they identify a continuum of disease severity. Consequently, many healthy people who have abnormal screening tests are wrongly diagnosed. Indeed, studies have demonstrated that for each screening-prevented death from cancer, at least 200 false-positive results are given. Therefore, screening has the potential to be harmful as well as beneficial. The psychosocial consequences of false-positive screening results cannot be determined by diagnostic tests or by other technical means. Instead, patient reported outcome measures must be employed. To measure the outcomes of screening accurately and comprehensively patient reported outcome measures have to capture; the nature and extent of the psychosocial consequences and how these change over time. The outcome measures used must have high content validity and their psychometric properties should be determined prior to their use in the specific population. In particular it is important to establish unidimensionality, additivity and item ordering through the application of Item Response Theory. PMID:17210071

Top