Sample records for fast diagnostic camera

  1. A Fast Visible Camera Divertor-Imaging Diagnostic on DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roquemore, A; Maingi, R; Lasnier, C

    2007-06-19

    In recent campaigns, the Photron Ultima SE fast framing camera has proven to be a powerful diagnostic when applied to imaging divertor phenomena on the National Spherical Torus Experiment (NSTX). Active areas of NSTX divertor research addressed with the fast camera include identification of types of EDGE Localized Modes (ELMs)[1], dust migration, impurity behavior and a number of phenomena related to turbulence. To compare such edge and divertor phenomena in low and high aspect ratio plasmas, a multi-institutional collaboration was developed for fast visible imaging on NSTX and DIII-D. More specifically, the collaboration was proposed to compare the NSTX smallmore » type V ELM regime [2] and the residual ELMs observed during Type I ELM suppression with external magnetic perturbations on DIII-D[3]. As part of the collaboration effort, the Photron camera was installed recently on DIII-D with a tangential view similar to the view implemented on NSTX, enabling a direct comparison between the two machines. The rapid implementation was facilitated by utilization of the existing optics that coupled the visible spectral output from the divertor vacuum ultraviolet UVTV system, which has a view similar to the view developed for the divertor tangential TV camera [4]. A remote controlled filter wheel was implemented, as was the radiation shield required for the DIII-D installation. The installation and initial operation of the camera are described in this paper, and the first images from the DIII-D divertor are presented.« less

  2. Innovative diagnostics for ITER physics addressed in JET

    NASA Astrophysics Data System (ADS)

    Murari, A.; Edlington, T.; Alfier, A.; Alonso, A.; Andrew, Y.; Arnoux, G.; Beurskens, M.; Coad, P.; Crombe, C.; Gauthier, E.; Giroud, C.; Hidalgo, C.; Hong, S.; Kempenaars, M.; Kiptily, V.; Loarer, T.; Meigs, A.; Pasqualotto, R.; Tala, T.; Contributors, JET-EFDA

    2008-12-01

    In recent years, JET diagnostic capability has been significantly improved to widen the range of physical phenomena that can be studied and thus contribute to the understanding of some ITER relevant issues. The most significant results reported in this paper refer to the plasma wall interactions, the interplay between core and edge physics and fast particles. A synergy between new infrared cameras, visible cameras and spectroscopy diagnostics has allowed investigating a series of new aspects of the plasma wall interactions. The power loads on the plasma facing components of JET main chambers have been assessed at steady state and during transient events like ELMs and disruptions. Evidence of filaments in the edge region of the plasma has been collected with a new fast visible camera and high resolution Thomson scattering. The physics of detached plasmas and some new aspects of dust formation have also been devoted particular attention. The influence of the edge plasma on the core has been investigated with upgraded active spectroscopy, providing new information on momentum transport and the effects of impurity injection on ELMs and ITBs and their interdependence. Given the fact that JET is the only machine with a plasma volume big enough to confine the alphas, a coherent programme of diagnostic developments for the energetic particles has been undertaken. With upgraded γ-ray spectroscopy and a new scintillator probe, it is now possible to study both the redistribution and the losses of the fast particles in various plasma conditions.

  3. Overview of diagnostic performance and results for the first operation phase in Wendelstein 7-X (invited).

    PubMed

    Krychowiak, M; Adnan, A; Alonso, A; Andreeva, T; Baldzuhn, J; Barbui, T; Beurskens, M; Biel, W; Biedermann, C; Blackwell, B D; Bosch, H S; Bozhenkov, S; Brakel, R; Bräuer, T; Brotas de Carvalho, B; Burhenn, R; Buttenschön, B; Cappa, A; Cseh, G; Czarnecka, A; Dinklage, A; Drews, P; Dzikowicka, A; Effenberg, F; Endler, M; Erckmann, V; Estrada, T; Ford, O; Fornal, T; Frerichs, H; Fuchert, G; Geiger, J; Grulke, O; Harris, J H; Hartfuß, H J; Hartmann, D; Hathiramani, D; Hirsch, M; Höfel, U; Jabłoński, S; Jakubowski, M W; Kaczmarczyk, J; Klinger, T; Klose, S; Knauer, J; Kocsis, G; König, R; Kornejew, P; Krämer-Flecken, A; Krawczyk, N; Kremeyer, T; Książek, I; Kubkowska, M; Langenberg, A; Laqua, H P; Laux, M; Lazerson, S; Liang, Y; Liu, S C; Lorenz, A; Marchuk, A O; Marsen, S; Moncada, V; Naujoks, D; Neilson, H; Neubauer, O; Neuner, U; Niemann, H; Oosterbeek, J W; Otte, M; Pablant, N; Pasch, E; Sunn Pedersen, T; Pisano, F; Rahbarnia, K; Ryć, L; Schmitz, O; Schmuck, S; Schneider, W; Schröder, T; Schuhmacher, H; Schweer, B; Standley, B; Stange, T; Stephey, L; Svensson, J; Szabolics, T; Szepesi, T; Thomsen, H; Travere, J-M; Trimino Mora, H; Tsuchiya, H; Weir, G M; Wenzel, U; Werner, A; Wiegel, B; Windisch, T; Wolf, R; Wurden, G A; Zhang, D; Zimbal, A; Zoletnik, S

    2016-11-01

    Wendelstein 7-X, a superconducting optimized stellarator built in Greifswald/Germany, started its first plasmas with the last closed flux surface (LCFS) defined by 5 uncooled graphite limiters in December 2015. At the end of the 10 weeks long experimental campaign (OP1.1) more than 20 independent diagnostic systems were in operation, allowing detailed studies of many interesting plasma phenomena. For example, fast neutral gas manometers supported by video cameras (including one fast-frame camera with frame rates of tens of kHz) as well as visible cameras with different interference filters, with field of views covering all ten half-modules of the stellarator, discovered a MARFE-like radiation zone on the inboard side of machine module 4. This structure is presumably triggered by an inadvertent plasma-wall interaction in module 4 resulting in a high impurity influx that terminates some discharges by radiation cooling. The main plasma parameters achieved in OP1.1 exceeded predicted values in discharges of a length reaching 6 s. Although OP1.1 is characterized by short pulses, many of the diagnostics are already designed for quasi-steady state operation of 30 min discharges heated at 10 MW of ECRH. An overview of diagnostic performance for OP1.1 is given, including some highlights from the physics campaigns.

  4. Fast-camera imaging on the W7-X stellarator

    NASA Astrophysics Data System (ADS)

    Ballinger, S. B.; Terry, J. L.; Baek, S. G.; Tang, K.; Grulke, O.

    2017-10-01

    Fast cameras recording in the visible range have been used to study filamentary (``blob'') edge turbulence in tokamak plasmas, revealing that emissive filaments aligned with the magnetic field can propagate perpendicular to it at speeds on the order of 1 km/s in the SOL or private flux region. The motion of these filaments has been studied in several tokamaks, including MAST, NSTX, and Alcator C-Mod. Filaments were also observed in the W7-X Stellarator using fast cameras during its initial run campaign. For W7-X's upcoming 2017-18 run campaign, we have installed a Phantom V710 fast camera with a view of the machine cross section and part of a divertor module in order to continue studying edge and divertor filaments. The view is coupled to the camera via a coherent fiber bundle. The Phantom camera is able to record at up to 400,000 frames per second and has a spatial resolution of roughly 2 cm in the view. A beam-splitter is used to share the view with a slower machine-protection camera. Stepping-motor actuators tilt the beam-splitter about two orthogonal axes, making it possible to frame user-defined sub-regions anywhere within the view. The diagnostic has been prepared to be remotely controlled via MDSplus. The MIT portion of this work is supported by US DOE award DE-SC0014251.

  5. Overview of diagnostic performance and results for the first operation phase in Wendelstein 7-X (invited)

    DOE PAGES

    Krychowiak, M.

    2016-10-27

    Wendelstein 7-X, a superconducting optimized stellarator built in Greifswald/Germany, started its first plasmas with the last closed flux surface (LCFS) defined by 5 uncooled graphite limiters in December 2015. At the end of the 10 weeks long experimental campaign (OP1.1) more than 20 independent diagnostic systems were in operation, allowing detailed studies of many interesting plasma phenomena. For example, fast neutral gas manometers supported by video cameras (including one fast-frame camera with frame rates of tens of kHz) as well as visible cameras with different interference filters, with field of views covering all ten half-modules of the stellarator, discovered amore » MARFE-like radiation zone on the inboard side of machine module 4. This structure is presumably triggered by an inadvertent plasma-wall interaction in module 4 resulting in a high impurity influx that terminates some discharges by radiation cooling. The main plasma parameters achieved in OP1.1 exceeded predicted values in discharges of a length reaching 6 s. Although OP1.1 is characterized by short pulses, many of the diagnostics are already designed for quasi-steady state operation of 30 min discharges heated at 10 MW of ECRH. Finally, an overview of diagnostic performance for OP1.1 is given, including some highlights from the physics campaigns.« less

  6. Overview of diagnostic performance and results for the first operation phase in Wendelstein 7-X (invited)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krychowiak, M.

    Wendelstein 7-X, a superconducting optimized stellarator built in Greifswald/Germany, started its first plasmas with the last closed flux surface (LCFS) defined by 5 uncooled graphite limiters in December 2015. At the end of the 10 weeks long experimental campaign (OP1.1) more than 20 independent diagnostic systems were in operation, allowing detailed studies of many interesting plasma phenomena. For example, fast neutral gas manometers supported by video cameras (including one fast-frame camera with frame rates of tens of kHz) as well as visible cameras with different interference filters, with field of views covering all ten half-modules of the stellarator, discovered amore » MARFE-like radiation zone on the inboard side of machine module 4. This structure is presumably triggered by an inadvertent plasma-wall interaction in module 4 resulting in a high impurity influx that terminates some discharges by radiation cooling. The main plasma parameters achieved in OP1.1 exceeded predicted values in discharges of a length reaching 6 s. Although OP1.1 is characterized by short pulses, many of the diagnostics are already designed for quasi-steady state operation of 30 min discharges heated at 10 MW of ECRH. Finally, an overview of diagnostic performance for OP1.1 is given, including some highlights from the physics campaigns.« less

  7. Fast Fiber-Coupled Imaging Devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brockington, Samuel; Case, Andrew; Witherspoon, Franklin Douglas

    HyperV Technologies Corp. has successfully designed, built and experimentally demonstrated a full scale 1024 pixel 100 MegaFrames/s fiber coupled camera with 12 or 14 bits, and record lengths of 32K frames, exceeding our original performance objectives. This high-pixel-count, fiber optically-coupled, imaging diagnostic can be used for investigating fast, bright plasma events. In Phase 1 of this effort, a 100 pixel fiber-coupled fast streak camera for imaging plasma jet profiles was constructed and successfully demonstrated. The resulting response from outside plasma physics researchers emphasized development of increased pixel performance as a higher priority over increasing pixel count. In this Phase 2more » effort, HyperV therefore focused on increasing the sample rate and bit-depth of the photodiode pixel designed in Phase 1, while still maintaining a long record length and holding the cost per channel to levels which allowed up to 1024 pixels to be constructed. Cost per channel was 53.31 dollars, very close to our original target of $50 per channel. The system consists of an imaging "camera head" coupled to a photodiode bank with an array of optical fibers. The output of these fast photodiodes is then digitized at 100 Megaframes per second and stored in record lengths of 32,768 samples with bit depths of 12 to 14 bits per pixel. Longer record lengths are possible with additional memory. A prototype imaging system with up to 1024 pixels was designed and constructed and used to successfully take movies of very fast moving plasma jets as a demonstration of the camera performance capabilities. Some faulty electrical components on the 64 circuit boards resulted in only 1008 functional channels out of 1024 on this first generation prototype system. We experimentally observed backlit high speed fan blades in initial camera testing and then followed that with full movies and streak images of free flowing high speed plasma jets (at 30-50 km/s). Jet structure and jet collisions onto metal pillars in the path of the plasma jets were recorded in a single shot. This new fast imaging system is an attractive alternative to conventional fast framing cameras for applications and experiments where imaging events using existing techniques are inefficient or impossible. The development of HyperV's new diagnostic was split into two tracks: a next generation camera track, in which HyperV built, tested, and demonstrated a prototype 1024 channel camera at its own facility, and a second plasma community beta test track, where selected plasma physics programs received small systems of a few test pixels to evaluate the expected performance of a full scale camera on their experiments. These evaluations were performed as part of an unfunded collaboration with researchers at Los Alamos National Laboratory and the University of California at Davis. Results from the prototype 1024-pixel camera are discussed, as well as results from the collaborations with test pixel system deployment sites.« less

  8. A neutron camera system for MAST.

    PubMed

    Cecconello, M; Turnyanskiy, M; Conroy, S; Ericsson, G; Ronchi, E; Sangaroon, S; Akers, R; Fitzgerald, I; Cullen, A; Weiszflog, M

    2010-10-01

    A prototype neutron camera has been developed and installed at MAST as part of a feasibility study for a multichord neutron camera system with the aim to measure the spatial and time resolved 2.45 MeV neutron emissivity profile. Liquid scintillators coupled to a fast digitizer are used for neutron/gamma ray digital pulse shape discrimination. The preliminary results obtained clearly show the capability of this diagnostic to measure neutron emissivity profiles with sufficient time resolution to study the effect of fast ion loss and redistribution due to magnetohydrodynamic activity. A minimum time resolution of 2 ms has been achieved with a modest 1.5 MW of neutral beam injection heating with a measured neutron count rate of a few 100 kHz.

  9. Fast imaging diagnostics on the C-2U advanced beam-driven field-reversed configuration device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Granstedt, E. M., E-mail: egranstedt@trialphaenergy.com; Petrov, P.; Knapp, K.

    2016-11-15

    The C-2U device employed neutral beam injection, end-biasing, and various particle fueling techniques to sustain a Field-Reversed Configuration (FRC) plasma. As part of the diagnostic suite, two fast imaging instruments with radial and nearly axial plasma views were developed using a common camera platform. To achieve the necessary viewing geometry, imaging lenses were mounted behind re-entrant viewports attached to welded bellows. During gettering, the vacuum optics were retracted and isolated behind a gate valve permitting their removal if cleaning was necessary. The axial view incorporated a stainless-steel mirror in a protective cap assembly attached to the vacuum-side of the viewport.more » For each system, a custom lens-based, high-throughput optical periscope was designed to relay the plasma image about half a meter to a high-speed camera. Each instrument also contained a remote-controlled filter wheel, set between shots to isolate a particular hydrogen or impurity emission line. The design of the camera platform, imaging performance, and sample data for each view is presented.« less

  10. Fast imaging diagnostics on the C-2U advanced beam-driven field-reversed configuration device

    NASA Astrophysics Data System (ADS)

    Granstedt, E. M.; Petrov, P.; Knapp, K.; Cordero, M.; Patel, V.

    2016-11-01

    The C-2U device employed neutral beam injection, end-biasing, and various particle fueling techniques to sustain a Field-Reversed Configuration (FRC) plasma. As part of the diagnostic suite, two fast imaging instruments with radial and nearly axial plasma views were developed using a common camera platform. To achieve the necessary viewing geometry, imaging lenses were mounted behind re-entrant viewports attached to welded bellows. During gettering, the vacuum optics were retracted and isolated behind a gate valve permitting their removal if cleaning was necessary. The axial view incorporated a stainless-steel mirror in a protective cap assembly attached to the vacuum-side of the viewport. For each system, a custom lens-based, high-throughput optical periscope was designed to relay the plasma image about half a meter to a high-speed camera. Each instrument also contained a remote-controlled filter wheel, set between shots to isolate a particular hydrogen or impurity emission line. The design of the camera platform, imaging performance, and sample data for each view is presented.

  11. Overview of diagnostic implementation on Proto-MPEX at ORNL

    NASA Astrophysics Data System (ADS)

    Biewer, T. M.; Bigelow, T.; Caughman, J. B. O.; Fehling, D.; Goulding, R. H.; Gray, T. K.; Isler, R. C.; Martin, E. H.; Meitner, S.; Rapp, J.; Unterberg, E. A.; Dhaliwal, R. S.; Donovan, D.; Kafle, N.; Ray, H.; Shaw, G. C.; Showers, M.; Mosby, R.; Skeen, C.

    2015-11-01

    The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) recently began operating with an expanded diagnostic set. Approximately 100 sightlines have been established, delivering the plasma light emission to a ``patch panel'' in the diagnostic room for distribution to a variety of instruments: narrow-band filter spectroscopy, Doppler spectroscopy, laser induced breakdown spectroscopy, optical emission spectroscopy, and Thomson scattering. Additional diagnostic systems include: IR camera imaging, in-vessel thermocouples, ex-vessel fluoroptic probes, fast pressure gauges, visible camera imaging, microwave interferometry, a retarding-field energy analyzer, rf-compensated and ``double'' Langmuir probes, and B-dot probes. A data collection and archival system has been initiated using the MDSplus format. This effort capitalizes on a combination of new and legacy diagnostic hardware at ORNL and was accomplished largely through student labor. This work was supported by the US. D.O.E. contract DE-AC05-00OR22725.

  12. Dust measurements in tokamaks (invited).

    PubMed

    Rudakov, D L; Yu, J H; Boedo, J A; Hollmann, E M; Krasheninnikov, S I; Moyer, R A; Muller, S H; Pigarov, A Yu; Rosenberg, M; Smirnov, R D; West, W P; Boivin, R L; Bray, B D; Brooks, N H; Hyatt, A W; Wong, C P C; Roquemore, A L; Skinner, C H; Solomon, W M; Ratynskaia, S; Fenstermacher, M E; Groth, M; Lasnier, C J; McLean, A G; Stangeby, P C

    2008-10-01

    Dust production and accumulation present potential safety and operational issues for the ITER. Dust diagnostics can be divided into two groups: diagnostics of dust on surfaces and diagnostics of dust in plasma. Diagnostics from both groups are employed in contemporary tokamaks; new diagnostics suitable for ITER are also being developed and tested. Dust accumulation in ITER is likely to occur in hidden areas, e.g., between tiles and under divertor baffles. A novel electrostatic dust detector for monitoring dust in these regions has been developed and tested at PPPL. In the DIII-D tokamak dust diagnostics include Mie scattering from Nd:YAG lasers, visible imaging, and spectroscopy. Laser scattering is able to resolve particles between 0.16 and 1.6 microm in diameter; using these data the total dust content in the edge plasmas and trends in the dust production rates within this size range have been established. Individual dust particles are observed by visible imaging using fast framing cameras, detecting dust particles of a few microns in diameter and larger. Dust velocities and trajectories can be determined in two-dimension with a single camera or three-dimension using multiple cameras, but determination of particle size is challenging. In order to calibrate diagnostics and benchmark dust dynamics modeling, precharacterized carbon dust has been injected into the lower divertor of DIII-D. Injected dust is seen by cameras, and spectroscopic diagnostics observe an increase in carbon line (CI, CII, C(2) dimer) and thermal continuum emissions from the injected dust. The latter observation can be used in the design of novel dust survey diagnostics.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rudakov, D. L.; Yu, J. H.; Boedo, J. A.

    Dust production and accumulation present potential safety and operational issues for the ITER. Dust diagnostics can be divided into two groups: diagnostics of dust on surfaces and diagnostics of dust in plasma. Diagnostics from both groups are employed in contemporary tokamaks; new diagnostics suitable for ITER are also being developed and tested. Dust accumulation in ITER is likely to occur in hidden areas, e.g., between tiles and under divertor baffles. A novel electrostatic dust detector for monitoring dust in these regions has been developed and tested at PPPL. In the DIII-D tokamak dust diagnostics include Mie scattering from Nd:YAG lasers,more » visible imaging, and spectroscopy. Laser scattering is able to resolve particles between 0.16 and 1.6 {mu}m in diameter; using these data the total dust content in the edge plasmas and trends in the dust production rates within this size range have been established. Individual dust particles are observed by visible imaging using fast framing cameras, detecting dust particles of a few microns in diameter and larger. Dust velocities and trajectories can be determined in two-dimension with a single camera or three-dimension using multiple cameras, but determination of particle size is challenging. In order to calibrate diagnostics and benchmark dust dynamics modeling, precharacterized carbon dust has been injected into the lower divertor of DIII-D. Injected dust is seen by cameras, and spectroscopic diagnostics observe an increase in carbon line (CI, CII, C{sub 2} dimer) and thermal continuum emissions from the injected dust. The latter observation can be used in the design of novel dust survey diagnostics.« less

  14. Fast visible imaging of turbulent plasma in TORPEX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iraji, D.; Diallo, A.; Fasoli, A.

    2008-10-15

    Fast framing cameras constitute an important recent diagnostic development aimed at monitoring light emission from magnetically confined plasmas, and are now commonly used to study turbulence in plasmas. In the TORPEX toroidal device [A. Fasoli et al., Phys. Plasmas 13, 055902 (2006)], low frequency electrostatic fluctuations associated with drift-interchange waves are routinely measured by means of extensive sets of Langmuir probes. A Photron Ultima APX-RS fast framing camera has recently been acquired to complement Langmuir probe measurements, which allows comparing statistical and spectral properties of visible light and electrostatic fluctuations. A direct imaging system has been developed, which allows viewingmore » the light, emitted from microwave-produced plasmas tangentially and perpendicularly to the toroidal direction. The comparison of the probability density function, power spectral density, and autoconditional average of the camera data to those obtained using a multiple head electrostatic probe covering the plasma cross section shows reasonable agreement in the case of perpendicular view and in the plasma region where interchange modes dominate.« less

  15. Diagnostic Suite for HyperV Coaxial Plasma Gun Development for the PLX- α Project

    NASA Astrophysics Data System (ADS)

    Case, Andrew; Brockington, Sam; Witherspoon, F. Douglas

    2015-11-01

    We present the diagnostic suite to be used during development of the coaxial guns HyperV will deliver to LANL in support of the ARPA-E Accelerating Low-Cost Plasma Heating And Assembly (ALPHA) program. For plasma jet diagnostics this includes fast photodiodes for velocimetry, a ballistic pendulum for measuring total plasmoid momentum, interferometry for line integrated plasma density, deflectometry for line integrated perpendicular density gradient measurements, and spectroscopy, both time resolved high resolution spectroscopy using a novel detector developed by HyperV and time integrated survey spectroscopy, for measurements of velocity and temperature as well as impurities. In addition, we plan to use fast pressure probes for stagnation pressure, a Faraday cup for density, fast imaging for plume geometry and time integrated imaging for overall light emission. A novel low resolution long record length camera developed by HyperV will also be used for plume diagnostics. For diagnostics of gun operation, we will use Rogowski coils to measure current, voltage dividers for voltages, B-dot probes for magnetic field, and time resolved fast photodiodes to measure plasmoid velocity inside the accelerator. This work supported by the ARPA-E ALPHA program.

  16. A poloidal section neutron camera for MAST upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sangaroon, S.; Weiszflog, M.; Cecconello, M.

    2014-08-21

    The Mega Ampere Spherical Tokamak Upgrade (MAST Upgrade) is intended as a demonstration of the physics viability of the Spherical Tokamak (ST) concept and as a platform for contributing to ITER/DEMO physics. Concerning physics exploitation, MAST Upgrade plasma scenarios can contribute to the ITER Tokamak physics particularly in the field of fast particle behavior and current drive studies. At present, MAST is equipped with a prototype neutron camera (NC). On the basis of the experience and results from previous experimental campaigns using the NC, the conceptual design of a neutron camera upgrade (NC Upgrade) is being developed. As part ofmore » the MAST Upgrade, the NC Upgrade is considered a high priority diagnostic since it would allow studies in the field of fast ions and current drive with good temporal and spatial resolution. In this paper, we explore an optional design with the camera array viewing the poloidal section of the plasma from different directions.« less

  17. High speed movies of turbulence in Alcator C-Mod

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Terry, J.L.; Zweben, S.J.; Bose, B.

    2004-10-01

    A high speed (250 kHz), 300 frame charge coupled device camera has been used to image turbulence in the Alcator C-Mod Tokamak. The camera system is described and some of its important characteristics are measured, including time response and uniformity over the field-of-view. The diagnostic has been used in two applications. One uses gas-puff imaging to illuminate the turbulence in the edge/scrape-off-layer region, where D{sub 2} gas puffs localize the emission in a plane perpendicular to the magnetic field when viewed by the camera system. The dynamics of the underlying turbulence around and outside the separatrix are detected in thismore » manner. In a second diagnostic application, the light from an injected, ablating, high speed Li pellet is observed radially from the outer midplane, and fast poloidal motion of toroidal striations are seen in the Li{sup +} light well inside the separatrix.« less

  18. Fast-ion Dα spectrum diagnostic in the EAST

    NASA Astrophysics Data System (ADS)

    Hou, Y. M.; Wu, C. R.; Huang, J.; Heidbrink, W. W.; von Hellermann, M. G.; Xu, Z.; Jin, Z.; Chang, J. F.; Zhu, Y. B.; Gao, W.; Chen, Y. J.; Lyu, B.; Hu, R. J.; Zhang, P. F.; Zhang, L.; Gao, W.; Wu, Z. W.; Yu, Y.; Ye, M. Y.

    2016-11-01

    In toroidal magnetic fusion devices, fast-ion D-alpha diagnostic (FIDA) is a powerful method to study the fast-ion feature. The fast-ion characteristics can be inferred from the Doppler shifted spectrum of Dα light according to charge exchange recombination process between fast ions and probe beam. Since conceptual design presented in the last HTPD conference, significant progress has been made to apply FIDA systems on the Experimental Advanced Superconducting Tokamak (EAST). Both co-current and counter-current neutral beam injectors are available, and each can deliver 2-4 MW beam power with 50-80 keV beam energy. Presently, two sets of high throughput spectrometer systems have been installed on EAST, allowing to capture passing and trapped fast-ion characteristics simultaneously, using Kaiser HoloSpec transmission grating spectrometer and Bunkoukeiki FLP-200 volume phase holographic spectrometer coupled with Princeton Instruments ProEM 1024B eXcelon and Andor DU-888 iXon3 1024 CCD camera, respectively. This paper will present the details of the hardware descriptions and experimental spectrum.

  19. Emission computerized axial tomography from multiple gamma-camera views using frequency filtering.

    PubMed

    Pelletier, J L; Milan, C; Touzery, C; Coitoux, P; Gailliard, P; Budinger, T F

    1980-01-01

    Emission computerized axial tomography is achievable in any nuclear medicine department from multiple gamma camera views. Data are collected by rotating the patient in front of the camera. A simple fast algorithm is implemented, known as the convolution technique: first the projection data are Fourier transformed and then an original filter designed for optimizing resolution and noise suppression is applied; finally the inverse transform of the latter operation is back-projected. This program, which can also take into account the attenuation for single photon events, was executed with good results on phantoms and patients. We think that it can be easily implemented for specific diagnostic problems.

  20. High speed photography, videography, and photonics III; Proceedings of the Meeting, San Diego, CA, August 22, 23, 1985

    NASA Technical Reports Server (NTRS)

    Ponseggi, B. G. (Editor); Johnson, H. C. (Editor)

    1985-01-01

    Papers are presented on the picosecond electronic framing camera, photogrammetric techniques using high-speed cineradiography, picosecond semiconductor lasers for characterizing high-speed image shutters, the measurement of dynamic strain by high-speed moire photography, the fast framing camera with independent frame adjustments, design considerations for a data recording system, and nanosecond optical shutters. Consideration is given to boundary-layer transition detectors, holographic imaging, laser holographic interferometry in wind tunnels, heterodyne holographic interferometry, a multispectral video imaging and analysis system, a gated intensified camera, a charge-injection-device profile camera, a gated silicon-intensified-target streak tube and nanosecond-gated photoemissive shutter tubes. Topics discussed include high time-space resolved photography of lasers, time-resolved X-ray spectrographic instrumentation for laser studies, a time-resolving X-ray spectrometer, a femtosecond streak camera, streak tubes and cameras, and a short pulse X-ray diagnostic development facility.

  1. Recent improvements of the JET lithium beam diagnostica)

    NASA Astrophysics Data System (ADS)

    Brix, M.; Dodt, D.; Dunai, D.; Lupelli, I.; Marsen, S.; Melson, T. F.; Meszaros, B.; Morgan, P.; Petravich, G.; Refy, D. I.; Silva, C.; Stamp, M.; Szabolics, T.; Zastrow, K.-D.; Zoletnik, S.; JET-EFDA Contributors

    2012-10-01

    A 60 kV neutral lithium diagnostic beam probes the edge plasma of JET for the measurement of electron density profiles. This paper describes recent enhancements of the diagnostic setup, new procedures for calibration and protection measures for the lithium ion gun during massive gas puffs for disruption mitigation. New light splitting optics allow in parallel beam emission measurements with a new double entrance slit CCD spectrometer (spectrally resolved) and a new interference filter avalanche photodiode camera (fast density and fluctuation studies).

  2. Fast, Deep-Record-Length, Fiber-Coupled Photodiode Imaging Array for Plasma Diagnostics

    NASA Astrophysics Data System (ADS)

    Brockington, Samuel; Case, Andrew; Witherspoon, F. Douglas

    2015-11-01

    HyperV Technologies has been developing an imaging diagnostic comprised of an array of fast, low-cost, long-record-length, fiber-optically-coupled photodiode channels to investigate plasma dynamics and other fast, bright events. By coupling an imaging fiber bundle to a bank of amplified photodiode channels, imagers and streak imagers can be constructed. By interfacing analog photodiode systems directly to commercial analog-to-digital converters and modern memory chips, a scalable solution for 100 to 1000 pixel systems with 14 bit resolution and record-lengths of 128k frames has been developed. HyperV is applying these techniques to construct a prototype 1000 Pixel framing camera with up to 100 Msamples/sec rate and 10 to 14 bit depth. Preliminary experimental results as well as future plans will be discussed. Work supported by USDOE Phase 2 SBIR Grant DE-SC0009492.

  3. Fast, Deep-Record-Length, Fiber-Coupled Photodiode Imaging Array for Plasma Diagnostics

    NASA Astrophysics Data System (ADS)

    Brockington, Samuel; Case, Andrew; Witherspoon, F. Douglas

    2014-10-01

    HyperV Technologies has been developing an imaging diagnostic comprised of an array of fast, low-cost, long-record-length, fiber-optically-coupled photodiode channels to investigate plasma dynamics and other fast, bright events. By coupling an imaging fiber bundle to a bank of amplified photodiode channels, imagers and streak imagers of 100 to 1000 pixels can be constructed. By interfacing analog photodiode systems directly to commercial analog-to-digital converters and modern memory chips, a prototype 100 pixel array with an extremely deep record length (128 k points at 20 Msamples/s) and 10 bit pixel resolution has already been achieved. HyperV now seeks to extend these techniques to construct a prototype 1000 Pixel framing camera with up to 100 Msamples/sec rate and 10 to 12 bit depth. Preliminary experimental results as well as Phase 2 plans will be discussed. Work supported by USDOE Phase 2 SBIR Grant DE-SC0009492.

  4. Intense ion beam diagnostics for ICF

    NASA Astrophysics Data System (ADS)

    Yasuike, K.; Cuneo, M. E.; Wenger, D. F.; Bailey, J. E.; Hanson, D. L.; Mehlhorn, T. A.; Imasaki, K.; Nakai, S.; Mima, K.

    1998-11-01

    Development of diagnostic methods for high intensity ion beams for ICF is crucial for understanding the ion diode physics. At Osaka University, an arrayed pinhole camera (APC) diagnostic method had been developed to measure the proton beams with an energy of 1 MeV and a J_i. of 100 A/cm^2. on Reiden-SHVS. The APC measures spatial distributions of the beam divergence in r and θ drection and the intensity distribution. An ion image detector capable to acquire a whole temporal evolution within a shot is necessary to measure the higher intensity beams. A fast scintillator with photo-multiplier tubes has been chosen as the image detector. The detector is being tested on a single pinhole camera using a Lithium beam with a particle energy of 5 MeV, a J_i. of 0.5-1 kA/cm^2. and duration of 50 ns, which are very close to the parameters required from ICF, on the SABRE at Sandia National Labs. We will present the diagnostic design and preliminary experiments from SABRE and also present the experimental results from Reiden-SHVS.

  5. Optical diagnostics of the arc plasma using fast intensified CCD-spectrograph system

    NASA Astrophysics Data System (ADS)

    Pavelescu, Gabriela; Guillot, Stephane; Braic, Mariana T.; Hong, Dunpin; Pavelescu, D.; Fleurier, Claude; Braic, Viorel; Gherendi, F.; Dumitrescu, G.; Anghelita, P.; Bauchire, J. M.

    2004-10-01

    Spectroscopic diagnostics, using intensified high speed CCD camera, was applied to study the arc dynamics in low voltage circuit breakers, in vacuum and in air. Time-resolved emission spectroscopy of the vacuum arc plasma, generated during electrode separation, provided information about the interruption process. The investigations were focused on the partial unsuccessful interruption around current zero. Absorption spectroscopy, in a peculiar setup, was used in order to determine the metallic atoms densities in the interelectrode space of a low voltage circuit breaker, working in ambient air.

  6. Scintillator-based fast ion loss measurements in the EAST.

    PubMed

    Chang, J F; Isobe, M; Ogawa, K; Huang, J; Wu, C R; Xu, Z; Jin, Z; Lin, S Y; Hu, L Q

    2016-11-01

    A new scintillator-based fast ion loss detector (FILD) has been installed on Experimental Advanced Superconducting Tokamak (EAST) to investigate the fast ion loss behavior in high performance plasma with neutral beam injection (NBI) and ion cyclotron resonance heating (ICRH). A two dimensional 40 mm × 40 mm scintillator-coated (ZnS:Ag) stainless plate is mounted in the front of the detector, capturing the escaping fast ions. Photons from the scintillator plate are imaged with a Phantom V2010 CCD camera. The lost fast ions can be measured with the pitch angle from 60° to 120° and the gyroradius from 10 mm to 180 mm. This paper will describe the details of FILD diagnostic on EAST and describe preliminary measurements during NBI and ICRH heating.

  7. New developments in the diagnostics for the fusion products on JET in preparation for ITER (invited).

    PubMed

    Murari, A; Angelone, M; Bonheure, G; Cecil, E; Craciunescu, T; Darrow, D; Edlington, T; Ericsson, G; Gatu-Johnson, M; Gorini, G; Hellesen, C; Kiptily, V; Mlynar, J; Perez von Thun, C; Pillon, M; Popovichev, S; Syme, B; Tardocchi, M; Zoita, V L

    2010-10-01

    Notwithstanding the advances of the past decades, significant developments are still needed to satisfactorily diagnose “burning plasmas.” D–T plasmas indeed require a series of additional measurements for the optimization and control of the configuration: the 14 MeV neutrons, the isotopic composition of the main plasma, the helium ash, and the redistribution and losses of the alpha particles. Moreover a burning plasma environment is in general much more hostile for diagnostics than purely deuterium plasmas. Therefore, in addition to the development and refinement of new measuring techniques, technological advances are also indispensable for the proper characterization of the next generation of devices. On JET an integrated program of diagnostic developments, for JET future and in preparation for ITER, has been pursued and many new results are now available. In the field of neutron detection, the neutron spectra are now routinely measured in the energy range of 1–18 MeV by a time of flight spectrometer and they have allowed studying the effects of rf heating on the fast ions. A new analysis method for the interpretation of the neutron cameras measurements has been refined and applied to the data of the last trace tritium campaign (TTE). With regard to technological upgrades, chemical vapor deposition diamond detectors have been qualified both as neutron counters and as neutron spectrometers, with a potential energy resolution of about one percent. The in situ calibration of the neutron diagnostics, in preparation for the operation with the ITER-like wall, is also promoting important technological developments. With regard to the fast particles, for the first time the temperature of the fast particle tails has been obtained with a new high purity Germanium detector measuring the gamma emission spectrum from the plasma. The effects of toroidal Alfven eigenmodes modes and various MHD instabilities on the confinement of the fast particles have been determined with a combination of gamma ray cameras, neutral particle analyzers, scintillator probe, and Faraday cups. From a more technological perspective, various neutron filters have been tested to allow measurement of the gamma ray emission also at high level of neutron yield.

  8. New developments in the diagnostics for the fusion products on JET in preparation for ITER (invited)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murari, A.; Angelone, M.; Pillon, M.

    Notwithstanding the advances of the past decades, significant developments are still needed to satisfactorily diagnose ''burning plasmas.'' D-T plasmas indeed require a series of additional measurements for the optimization and control of the configuration: the 14 MeV neutrons, the isotopic composition of the main plasma, the helium ash, and the redistribution and losses of the alpha particles. Moreover a burning plasma environment is in general much more hostile for diagnostics than purely deuterium plasmas. Therefore, in addition to the development and refinement of new measuring techniques, technological advances are also indispensable for the proper characterization of the next generation ofmore » devices. On JET an integrated program of diagnostic developments, for JET future and in preparation for ITER, has been pursued and many new results are now available. In the field of neutron detection, the neutron spectra are now routinely measured in the energy range of 1-18 MeV by a time of flight spectrometer and they have allowed studying the effects of rf heating on the fast ions.A new analysis method for the interpretation of the neutron cameras measurements has been refined and applied to the data of the last trace tritium campaign (TTE). With regard to technological upgrades, chemical vapor deposition diamond detectors have been qualified both as neutron counters and as neutron spectrometers, with a potential energy resolution of about one percent. The in situ calibration of the neutron diagnostics, in preparation for the operation with the ITER-like wall, is also promoting important technological developments. With regard to the fast particles, for the first time the temperature of the fast particle tails has been obtained with a new high purity Germanium detector measuring the gamma emission spectrum from the plasma. The effects of toroidal Alfven eigenmodes modes and various MHD instabilities on the confinement of the fast particles have been determined with a combination of gamma ray cameras, neutral particle analyzers, scintillator probe, and Faraday cups. From a more technological perspective, various neutron filters have been tested to allow measurement of the gamma ray emission also at high level of neutron yield.« less

  9. Distribution of biomolecules in porous nitrocellulose membrane pads using confocal laser scanning microscopy and high-speed cameras.

    PubMed

    Mujawar, Liyakat Hamid; Maan, Abid Aslam; Khan, Muhammad Kashif Iqbal; Norde, Willem; van Amerongen, Aart

    2013-04-02

    The main focus of our research was to study the distribution of inkjet printed biomolecules in porous nitrocellulose membrane pads of different brands. We produced microarrays of fluorophore-labeled IgG and bovine serum albumin (BSA) on FAST, Unisart, and Oncyte-Avid slides and compared the spot morphology of the inkjet printed biomolecules. The distribution of these biomolecules within the spot embedded in the nitrocellulose membrane was analyzed by confocal laser scanning microscopy in the "Z" stack mode. By applying a "concentric ring" format, the distribution profile of the fluorescence intensity in each horizontal slice was measured and represented in a graphical color-coded way. Furthermore, a one-step diagnostic antibody assay was performed with a primary antibody, double-labeled amplicons, and fluorophore-labeled streptavidin in order to study the functionality and distribution of the immune complex in the nitrocellulose membrane slides. Under the conditions applied, the spot morphology and distribution of the primary labeled biomolecules was nonhomogenous and doughnut-like on the FAST and Unisart nitrocellulose slides, whereas a better spot morphology with more homogeneously distributed biomolecules was observed on the Oncyte-Avid slide. Similar morphologies and distribution patterns were observed when the diagnostic one-step nucleic acid microarray immunoassay was performed on these nitrocellulose slides. We also investigated possible reasons for the differences in the observed spot morphology by monitoring the dynamic behavior of a liquid droplet on and in these nitrocellulose slides. Using high speed cameras, we analyzed the wettability and fluid flow dynamics of a droplet on the various nitrocellulose substrates. The spreading of the liquid droplet was comparable for the FAST and Unisart slides but different, i.e., slower, for the Oncyte-Avid slide. The results of the spreading of the droplet and the penetration behavior of the liquid in the nitrocellulose membrane may (partly) explain the distribution of the biomolecules in the different slides. To our knowledge, this is the first time that fluid dynamics in diagnostic membranes have been analyzed by the use of high-speed cameras.

  10. Can YAG screen accept LEReC bunch train?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seletskiy, S.; Thieberger, P.; Miller, T.

    2016-05-18

    LEReC RF diagnostic beamline is supposed to accept 250 us long pulse trains of 1.6 MeV – 2.6 MeV (kinetic energy) electrons. This beamline is equipped with YAG profile monitor. Since we are interested in observing only the last macro bunch in the train, one of the possibilities is to install a fast kicker and a dedicated dump upstream of the YAG screen (and related diagnostics equipment). This approach is expensive and challenging from engineering point of view. Another possibility is to send the whole pulse train to the YAG screen and to use a fast gated camera (such asmore » Imperex B0610 with trigger jitter under 60ns) to observe the image from the last pulse only. In this paper we study the feasibility of the last approach.« less

  11. Control and automation of the Pegasus multi-point Thomson scattering system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bodner, G. M., E-mail: gbodner@wisc.edu; Bongard, M. W.; Fonck, R. J.

    A new control system for the Pegasus Thomson scattering diagnostic has recently been deployed to automate the laser operation, data collection process, and interface with the system-wide Pegasus control code. Automation has been extended to areas outside of data collection, such as manipulation of beamline cameras and remotely controlled turning mirror actuators to enable intra-shot beam alignment. Additionally, the system has been upgraded with a set of fast (∼1 ms) mechanical shutters to mitigate contamination from background light. Modification and automation of the Thomson system have improved both data quality and diagnostic reliability.

  12. Control and automation of the Pegasus multi-point Thomson scattering system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bodner, Grant M.; Bongard, Michael W.; Fonck, Raymond J.

    A new control system for the Pegasus Thomson scattering diagnostic has recently been deployed to automate the laser operation, data collection process, and interface with the system-wide Pegasus control code. Automation has been extended to areas outside of data collection, such as manipulation of beamline cameras and remotely controlled turning mirror actuators to enable intra-shot beam alignment. In addition, the system has been upgraded with a set of fast (~1 ms) mechanical shutters to mitigate contamination from background light. Modification and automation of the Thomson system have improved both data quality and diagnostic reliability.

  13. Control and automation of the Pegasus multi-point Thomson scattering system

    DOE PAGES

    Bodner, Grant M.; Bongard, Michael W.; Fonck, Raymond J.; ...

    2016-08-12

    A new control system for the Pegasus Thomson scattering diagnostic has recently been deployed to automate the laser operation, data collection process, and interface with the system-wide Pegasus control code. Automation has been extended to areas outside of data collection, such as manipulation of beamline cameras and remotely controlled turning mirror actuators to enable intra-shot beam alignment. In addition, the system has been upgraded with a set of fast (~1 ms) mechanical shutters to mitigate contamination from background light. Modification and automation of the Thomson system have improved both data quality and diagnostic reliability.

  14. Time-resolved optical measurements of the post-detonation combustion of aluminized explosives

    NASA Astrophysics Data System (ADS)

    Carney, Joel R.; Miller, J. Scott; Gump, Jared C.; Pangilinan, G. I.

    2006-06-01

    The dynamic observation and characterization of light emission following the detonation and subsequent combustion of an aluminized explosive is described. The temporal, spatial, and spectral specificity of the light emission are achieved using a combination of optical diagnostics. Aluminum and aluminum monoxide emission peaks are monitored as a function of time and space using streak camera based spectroscopy in a number of light collection configurations. Peak areas of selected aluminum containing species are tracked as a function of time to ascertain the relative kinetics (growth and decay of emitting species) during the energetic event. At the chosen streak camera sensitivity, aluminum emission is observed for 10μs following the detonation of a confined 20g charge of PBXN-113, while aluminum monoxide emission persists longer than 20μs. A broadband optical emission gauge, shock velocity gauge, and fast digital framing camera are used as supplemental optical diagnostics. In-line, collimated detection is determined to be the optimum light collection geometry because it is independent of distance between the optics and the explosive charge. The chosen optical configuration also promotes a constant cylindrical collection volume that should facilitate future modeling efforts.

  15. A 10MHz Fiber-Coupled Photodiode Imaging Array for Plasma Diagnostics

    NASA Astrophysics Data System (ADS)

    Brockington, Samuel; Case, Andrew; Witherspoon, F. Douglas

    2013-10-01

    HyperV Technologies has been developing an imaging diagnostic comprised of arrays of fast, low-cost, long-record-length, fiber-optically-coupled photodiode channels to investigate plasma dynamics and other fast, bright events. By coupling an imaging fiber bundle to a bank of amplified photodiode channels, imagers and streak imagers of 100 to 10,000 pixels can be constructed. By interfacing analog photodiode systems directly to commercial analog to digital convertors and modern memory chips, a prototype pixel with an extremely deep record length (128 k points at 40 Msamples/s) has been achieved for a 10 bit resolution system with signal bandwidths of at least 10 MHz. Progress on a prototype 100 Pixel streak camera employing this technique is discussed along with preliminary experimental results and plans for a 10,000 pixel imager. Work supported by USDOE Phase 1 SBIR Grant DE-SC0009492.

  16. Fast soft x-ray images of magnetohydrodynamic phenomena in NSTX.

    PubMed

    Bush, C E; Stratton, B C; Robinson, J; Zakharov, L E; Fredrickson, E D; Stutman, D; Tritz, K

    2008-10-01

    A variety of magnetohydrodynamic (MHD) phenomena have been observed on NSTX. Many of these affect fast particle losses, which are of major concern for future burning plasma experiments. Usual diagnostics for studying these phenomena are arrays of Mirnov coils for magnetic oscillations and p-i-n diode arrays for soft x-ray emission from the plasma core. Data reported here are from a unique fast soft x-ray imaging camera (FSXIC) with a wide-angle (pinhole) tangential view of the entire plasma minor cross section. The camera provides a 64x64 pixel image, on a charge coupled device chip, of light resulting from conversion of soft x rays incident on a phosphor to the visible. We have acquired plasma images at frame rates of 1-500 kHz (300 frames/shot) and have observed a variety of MHD phenomena: disruptions, sawteeth, fishbones, tearing modes, and edge localized modes (ELMs). New data including modes with frequency >90 kHz are also presented. Data analysis and modeling techniques used to interpret the FSXIC data are described and compared, and FSXIC results are compared to Mirnov and p-i-n diode array results.

  17. First measurements of Dα spectrum produced by anisotropic fast ions in the gas dynamic trap

    NASA Astrophysics Data System (ADS)

    Lizunov, A.; Anikeev, A.

    2014-11-01

    Angled injection of eight deuterium beams in gas dynamic trap (GDT) plasmas builds up the population of fast ions with the distribution function, which conserves a high degree of initial anisotropy in space, energy, and pitch angle. Unlike the Maxwellian distribution case, the fast ion plasma component in GDT cannot be exhaustively characterized by the temperature and density. The instrumentation complex to study of fast ions is comprised of motional Stark effect diagnostic, analyzers of charge exchange atoms, and others. The set of numerical codes using for equilibrium modeling is also an important tool of analysis. In the recent campaign of summer 2014, we recorded first signals from the new fast ion D-alpha diagnostic on GDT. This paper presents the diagnostic description and results of pilot measurements. The diagnostic has four lines of sight, distributed across the radius of an axially symmetric plasma column in GDT. In the present setup, a line-integrated optical signal is measured in each channel. In the transverse direction, the spatial resolution is 18 mm. Collected light comes to the grating spectrometer with the low-noise detector based on a charge-coupled device matrix. In the regime of four spectra stacked vertically on the sensor, the effective spectral resolution of measurements is approximately 0.015 nm. Exposure timing is provided by the fast optical ferroelectric crystal shutter, allowing frames of duration down to 70 μs. This number represents the time resolution of measurements. A large dynamic range of the camera permits for a measurement of relatively small light signals produced by fast ions on top of the bright background emission from the bulk plasma. The fast ion emission has a non-Gaussian spectrum featuring the characteristic width of approximately 4 nm, which can be separated from relatively narrow Gaussian lines of D-alpha and H-alpha coming from the plasma periphery, and diagnostic beam emission. The signal to noise ratio varies from approximately ten for the central channel to approximately five for the outermost channel. We used the special set of Monte Carlo codes to fit the measured spectra. The shape of model fit shows a good agreement with the experimental fast ion D-alpha spectrum.

  18. Diagnostics for PLX-alpha

    NASA Astrophysics Data System (ADS)

    Gilmore, Mark; Hsu, Scott

    2015-11-01

    The goal of the Plasma Liner eXperiment PLX-alpha at Los Alamos National Laboratory is to establish the viability of creating a spherically imploding plasma liner for MIF and HED applications, using a spherical array of supersonic plasma jets launched by innovative contoured-gap coaxial plasma guns. PLX- α experiments will focus in particular on establishing the ram pressure and uniformity scalings of partial and fully spherical plasma liners. In order to characterize these parameters experimentally, a suite of diagnostics is planned, including multi-camera fast imaging, a 16-channel visible interferometer (upgraded from 8 channels) with reconfigurable, fiber-coupled front end, and visible and VUV high-resolution and survey spectroscopy. Tomographic reconstruction and data fusion techniques will be used in conjunction with interferometry, imaging, and synthetic diagnostics from modeling to characterize liner uniformity in 3D. Diagnostic and data analysis design, implementation, and status will be presented. Supported by the Advanced Research Projects Agency - Energy - U.S. Department of Energy.

  19. Behavior of Compact Toroid Injected into C-2U Confinement Vessel

    NASA Astrophysics Data System (ADS)

    Matsumoto, Tadafumi; Roche, T.; Allrey, I.; Sekiguchi, J.; Asai, T.; Conroy, M.; Gota, H.; Granstedt, E.; Hooper, C.; Kinley, J.; Valentine, T.; Waggoner, W.; Binderbauer, M.; Tajima, T.; the TAE Team

    2016-10-01

    The compact toroid (CT) injector system has been developed for particle refueling on the C-2U device. A CT is formed by a magnetized coaxial plasma gun (MCPG) and the typical ejected CT/plasmoid parameters are as follows: average velocity 100 km/s, average electron density 1.9 ×1015 cm-3, electron temperature 30-40 eV, mass 12 μg . To refuel particles into FC plasma the CT must penetrate the transverse magnetic field that surrounds the FRC. The kinetic energy density of the CT should be higher than magnetic energy density of the axial magnetic field, i.e., ρv2 / 2 >=B2 / 2μ0 , where ρ, v, and B are mass density, velocity, and surrounded magnetic field, respectively. Also, the penetrated CT's trajectory is deflected by the transverse magnetic field (Bz 1 kG). Thus, we have to estimate CT's energy and track the CT trajectory inside the magnetic field, for which we adopted a fast-framing camera on C-2U: framing rate is up to 1.25 MHz for 120 frames. By employing the camera we clearly captured the CT/plasmoid trajectory. Comparisons between the fast-framing camera and some other diagnostics as well as CT injection results on C-2U will be presented.

  20. Developments of fast emittance monitors for ion sources at RCNP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yorita, T., E-mail: yorita@rcnp.osaka-u.ac.jp; Hatanaka, K.; Fukuda, M.

    2016-02-15

    Recently, several developments of low energy beam transport line and its beam diagnostic systems have been performed to improve the injection efficiency of ion beam to azimuthally varying field cyclotron at Research Center for Nuclear Physics, Osaka University. One of those is the fast emittance monitor which can measure within several seconds for the efficient beam development and a Pepper-Pot Emittance Monitor (PPEM) has been developed. The PPEM consists of pepper-pot mask, multichannel plate, fluorescent screen, mirror, and CCD camera. The CCD image is taken via IEEE1394b to a personal computer and analyzed immediately and frequently, and then real timemore » measurement with about 2 Hz has been achieved.« less

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, M. C., E-mail: mthompson@trialphaenergy.com; Gota, H.; Putvinski, S.

    The C-2U experiment at Tri Alpha Energy studies the evolution of field-reversed configuration (FRC) plasmas sustained by neutral beam injection. Data on the FRC plasma performance are provided by a comprehensive suite of diagnostics that includes magnetic sensors, interferometry, Thomson scattering, spectroscopy, bolometry, reflectometry, neutral particle analyzers, and fusion product detectors. While many of these diagnostic systems were inherited from the preceding experiment C-2, C-2U has a variety of new and upgraded diagnostic systems: multi-chord far-infrared polarimetry, multiple fast imaging cameras with selectable atomic line filters, proton detector arrays, and 100 channel bolometer units capable of observing multiple regions ofmore » the spectrum simultaneously. In addition, extensive ongoing work focuses on advanced methods of measuring separatrix shape and plasma current profile that will facilitate equilibrium reconstruction and active control of the FRC plasma.« less

  2. Phone camera detection of glucose blood level based on magnetic particles entrapped inside bubble wrap.

    PubMed

    Martinkova, Pavla; Pohanka, Miroslav

    2016-12-18

    Glucose is an important diagnostic biochemical marker of diabetes but also for organophosphates, carbamates, acetaminophens or salicylates poisoning. Hence, innovation of accurate and fast detection assay is still one of priorities in biomedical research. Glucose sensor based on magnetic particles (MPs) with immobilized enzymes glucose oxidase (GOx) and horseradish peroxidase (HRP) was developed and the GOx catalyzed reaction was visualized by a smart-phone-integrated camera. Exponential decay concentration curve with correlation coefficient 0.997 and with limit of detection 0.4 mmol/l was achieved. Interfering and matrix substances were measured due to possibility of assay influencing and no effect of the tested substances was observed. Spiked plasma samples were also measured and no influence of plasma matrix on the assay was proved. The presented assay showed complying results with reference method (standard spectrophotometry based on enzymes glucose oxidase and peroxidase inside plastic cuvettes) with linear dependence and correlation coefficient 0.999 in concentration range between 0 and 4 mmol/l. On the grounds of measured results, method was considered as highly specific, accurate and fast assay for detection of glucose.

  3. Multi-energy SXR cameras for magnetically confined fusion plasmas (invited)

    NASA Astrophysics Data System (ADS)

    Delgado-Aparicio, L. F.; Maddox, J.; Pablant, N.; Hill, K.; Bitter, M.; Rice, J. E.; Granetz, R.; Hubbard, A.; Irby, J.; Greenwald, M.; Marmar, E.; Tritz, K.; Stutman, D.; Stratton, B.; Efthimion, P.

    2016-11-01

    A compact multi-energy soft x-ray camera has been developed for time, energy and space-resolved measurements of the soft-x-ray emissivity in magnetically confined fusion plasmas. Multi-energy soft x-ray imaging provides a unique opportunity for measuring, simultaneously, a variety of important plasma properties (Te, nZ, ΔZeff, and ne,fast). The electron temperature can be obtained by modeling the slope of the continuum radiation from ratios of the available brightness and inverted radial emissivity profiles over multiple energy ranges. Impurity density measurements are also possible using the line-emission from medium- to high-Z impurities to separate the background as well as transient levels of metal contributions. This technique should be explored also as a burning plasma diagnostic in-view of its simplicity and robustness.

  4. Knee, Shoulder, and Fundamentals of Arthroscopic Surgery Training: Validation of a Virtual Arthroscopy Simulator.

    PubMed

    Tofte, Josef N; Westerlind, Brian O; Martin, Kevin D; Guetschow, Brian L; Uribe-Echevarria, Bastián; Rungprai, Chamnanni; Phisitkul, Phinit

    2017-03-01

    To validate the knee, shoulder, and virtual Fundamentals of Arthroscopic Training (FAST) modules on a virtual arthroscopy simulator via correlations with arthroscopy case experience and postgraduate year. Orthopaedic residents and faculty from one institution performed a standardized sequence of knee, shoulder, and FAST modules to evaluate baseline arthroscopy skills. Total operation time, camera path length, and composite total score (metric derived from multiple simulator measurements) were compared with case experience and postgraduate level. Values reported are Pearson r; alpha = 0.05. 35 orthopaedic residents (6 per postgraduate year), 2 fellows, and 3 faculty members (2 sports, 1 foot and ankle), including 30 male and 5 female residents, were voluntarily enrolled March to June 2015. Knee: training year correlated significantly with year-averaged knee composite score, r = 0.92, P = .004, 95% confidence interval (CI) = 0.84, 0.96; operation time, r = -0.92, P = .004, 95% CI = -0.96, -0.84; and camera path length, r = -0.97, P = .0004, 95% CI = -0.98, -0.93. Knee arthroscopy case experience correlated significantly with composite score, r = 0.58, P = .0008, 95% CI = 0.27, 0.77; operation time, r = -0.54, P = .002, 95% CI = -0.75, -0.22; and camera path length, r = -0.62, P = .0003, 95% CI = -0.8, -0.33. Shoulder: training year correlated strongly with average shoulder composite score, r = 0.90, P = .006, 95% CI = 0.81, 0.95; operation time, r = -0.94, P = .001, 95% CI = -0.97, -0.89; and camera path length, r = -0.89, P = .007, 95% CI = -0.95, -0.80. Shoulder arthroscopy case experience correlated significantly with average composite score, r = 0.52, P = .003, 95% CI = 0.2, 0.74; strongly with operation time, r = -0.62, P = .0002, 95% CI = -0.8, -0.33; and camera path length, r = -0.37, P = .044, 95% CI = -0.64, -0.01, by training year. FAST: training year correlated significantly with 3 combined FAST activity average composite scores, r = 0.81, P = .0279, 95% CI = 0.65, 0.90; operation times, r = -0.86, P = .012, 95% CI = -0.93, -0.74; and camera path lengths, r = -0.85, P = .015, 95% CI = -0.92, -0.72. Total arthroscopy cases performed did not correlate significantly with overall FAST performance. We found significant correlations between both training year and knee and shoulder arthroscopy experience when compared with performance as measured by composite score, camera path length, and operation time during a simulated diagnostic knee and shoulder arthroscopy, respectively. Three FAST activities demonstrated significant correlations with training year but not arthroscopy case experience as measured by composite score, camera path length, and operation time. We attempt to validate an arthroscopy simulator that could be used to supplement arthroscopy skills training for orthopaedic residents. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  5. High-Speed Linear Raman Spectroscopy for Instability Analysis of a Bluff Body Flame

    NASA Technical Reports Server (NTRS)

    Kojima, Jun; Fischer, David

    2013-01-01

    We report a high-speed laser diagnostics technique based on point-wise linear Raman spectroscopy for measuring the frequency content of a CH4-air premixed flame stabilized behind a circular bluff body. The technique, which primarily employs a Nd:YLF pulsed laser and a fast image-intensified CCD camera, successfully measures the time evolution of scalar parameters (N2, O2, CH4, and H2O) in the vortex-induced flame instability at a data rate of 1 kHz. Oscillation of the V-shaped flame front is quantified through frequency analysis of the combustion species data and their correlations. This technique promises to be a useful diagnostics tool for combustion instability studies.

  6. Extreme ultra-violet movie camera for imaging microsecond time scale magnetic reconnection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chai, Kil-Byoung; Bellan, Paul M.

    2013-12-15

    An ultra-fast extreme ultra-violet (EUV) movie camera has been developed for imaging magnetic reconnection in the Caltech spheromak/astrophysical jet experiment. The camera consists of a broadband Mo:Si multilayer mirror, a fast decaying YAG:Ce scintillator, a visible light block, and a high-speed visible light CCD camera. The camera can capture EUV images as fast as 3.3 × 10{sup 6} frames per second with 0.5 cm spatial resolution. The spectral range is from 20 eV to 60 eV. EUV images reveal strong, transient, highly localized bursts of EUV radiation when magnetic reconnection occurs.

  7. Applications of Collisional Radiative Modeling of Helium and Deuterium for Image Tomography Diagnostic of Te, Ne, and ND in the DIII-D Tokamak

    NASA Astrophysics Data System (ADS)

    Munoz Burgos, J. M.; Brooks, N. H.; Fenstermacher, M. E.; Meyer, W. H.; Unterberg, E. A.; Schmitz, O.; Loch, S. D.; Balance, C. P.

    2011-10-01

    We apply new atomic modeling techniques to helium and deuterium for diagnostics in the divertor and scrape-off layer regions. Analysis of tomographically inverted images is useful for validating detachment prediction models and power balances in the divertor. We apply tomographic image inversion from fast tangential cameras of helium and Dα emission at the divertor in order to obtain 2D profiles of Te, Ne, and ND (neutral ion density profiles). The accuracy of the atomic models for He I will be cross-checked against Thomson scattering measurements of Te and Ne. This work summarizes several current developments and applications of atomic modeling into diagnostic at the DIII-D tokamak. Supported in part by the US DOE under DE-AC05-06OR23100, DE-FC02-04ER54698, DE-AC52-07NA27344, and DE-AC05-00OR22725.

  8. Coincidence ion imaging with a fast frame camera

    NASA Astrophysics Data System (ADS)

    Lee, Suk Kyoung; Cudry, Fadia; Lin, Yun Fei; Lingenfelter, Steven; Winney, Alexander H.; Fan, Lin; Li, Wen

    2014-12-01

    A new time- and position-sensitive particle detection system based on a fast frame CMOS (complementary metal-oxide semiconductors) camera is developed for coincidence ion imaging. The system is composed of four major components: a conventional microchannel plate/phosphor screen ion imager, a fast frame CMOS camera, a single anode photomultiplier tube (PMT), and a high-speed digitizer. The system collects the positional information of ions from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of a PMT processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum of a PMT. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide.

  9. Multi-energy SXR cameras for magnetically confined fusion plasmas (invited).

    PubMed

    Delgado-Aparicio, L F; Maddox, J; Pablant, N; Hill, K; Bitter, M; Rice, J E; Granetz, R; Hubbard, A; Irby, J; Greenwald, M; Marmar, E; Tritz, K; Stutman, D; Stratton, B; Efthimion, P

    2016-11-01

    A compact multi-energy soft x-ray camera has been developed for time, energy and space-resolved measurements of the soft-x-ray emissivity in magnetically confined fusion plasmas. Multi-energy soft x-ray imaging provides a unique opportunity for measuring, simultaneously, a variety of important plasma properties (T e , n Z , ΔZ eff , and n e,fast ). The electron temperature can be obtained by modeling the slope of the continuum radiation from ratios of the available brightness and inverted radial emissivity profiles over multiple energy ranges. Impurity density measurements are also possible using the line-emission from medium- to high-Z impurities to separate the background as well as transient levels of metal contributions. This technique should be explored also as a burning plasma diagnostic in-view of its simplicity and robustness.

  10. High Voltage Test-Stand Research Done on ICRF Antenna Elements of the High-Harmonic Fast-Wave System of NSTX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perkins, R. J.; Ahn, J.W.; Bortolon, A.

    The twelve-strap high-harmonic fast-wave (HHFW) antenna on NSTX has exhibited a high-voltage standoff around 25 kV during previous experimental campaigns; this standoff needs to be improved for increased power coupling. During the recent NSTX-U upgrade period, a test-stand was set up with two antenna straps along with Faraday screens for testing purposes. Using a diagnostic suite consisting of a fast camera, a residual gas analyzer, a pressure gage, high-voltage probes, and an infrared camera, several interesting discoveries were made, leading to possible improvements of the antenna RF voltage operation level. First, arcing was observed outside the Faraday shields towards themore » low-voltage ("grounded") end of the straps (faraday shield box ends); this arcing was successfully eliminated by installing an additional grounding point between the Faraday shield box and the vessel wall. Second, considerable outgassing was observed during the RF pulse and the amount of outgassing was found to decrease with increasing RF power, possibly indicative of multipacting. Finally, infrared camera measurements of heating on the Faraday shield assembly suggest that the return currents on the Faraday shield box are highly localized at the box sides and possibly account for the pressure increase observed. Computations of these RF currents using Microwave Studio show qualitative agreement with the heated regions. New grounding points between the antenna box and the vessel have been implemented in NSTX-U, where future tests will be done to determine if the high-voltage standoff has improved. Further antenna improvements will be sought through future experiments on the test stand.« less

  11. Synergy between fast-ion transport by core MHD and test blanket module fields in DIII-D experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heidbrink, W. W.; Austin, M. E.; Collins, C. S.

    2015-07-21

    We measured fast-ion transport caused by the combination of MHD and a mock-up test-blanket module (TBM) coil in the DIII-D tokamak. The primary diagnostic is an infrared camera that measures the heat flux on the tiles surrounding the coil. The combined effects of the TBM and four other potential sources of transport are studied: neoclassical tearing modes, Alfvén eigenmodes, sawteeth, and applied resonant magnetic perturbation fields for the control of edge localized modes. A definitive synergistic effect is observed at sawtooth crashes where, in the presence of the TBM, the localized heat flux at a burst increases from 0.36 ±0.27more » to 2.6 ±0.5 MW/m -2.« less

  12. Diagnostics Upgrades for Investigations of HOM Effects in TESLA-type SCRF Cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lumpkin, A. H.; Edstrom Jr., D.; Ruan, J.

    We describe the upgrades to diagnostic capabilities on the Fermilab Accelerator Science and Technology (FAST) electron linear accelerator that will allow investigations of the effects of high-order modes (HOMs) in SCRF cavities on macropulse-average beam quality. We examine the dipole modes in the first pass-band generally observed in the 1.6-1.9 GHz regime for TESLA-type SCRF cavities due to uniform transverse beam offsets of the electron beam. Such cavities are the basis of the accelerators such as the European XFEL and the proposed MaRIE XFEL facility. Preliminary HOM detector data, prototype BPM test data, and first framing camera OTR data withmore » ~20- micron spatial resolution at 250 pC per bunch will be presented.« less

  13. Simultaneous use of camera and probe diagnostics to unambiguously identify and study the dynamics of multiple underlying instabilities during the route to plasma turbulence.

    PubMed

    Thakur, S C; Brandt, C; Light, A; Cui, L; Gosselin, J J; Tynan, G R

    2014-11-01

    We use multiple-tip Langmuir probes and fast imaging to unambiguously identify and study the dynamics of underlying instabilities during the controlled route to fully-developed plasma turbulence in a linear magnetized helicon plasma device. Langmuir probes measure radial profiles of electron temperature, plasma density and potential; from which we compute linear growth rates of instabilities, cross-phase between density and potential fluctuations, Reynold's stress, particle flux, vorticity, time-delay estimated velocity, etc. Fast imaging complements the 1D probe measurements by providing temporally and spatially resolved 2D details of plasma structures associated with the instabilities. We find that three radially separated plasma instabilities exist simultaneously. Density gradient driven resistive drift waves propagating in the electron diamagnetic drift direction separate the plasma into an edge region dominated by strong, velocity shear driven Kelvin-Helmholtz instabilities and a central core region which shows coherent Rayleigh-Taylor modes propagating in the ion diamagnetic drift direction. The simultaneous, complementary use of both probes and camera was crucial to identify the instabilities and understand the details of the very rich plasma dynamics.

  14. Evaluation of the aero-optical properties of the SOFIA cavity by means of computional fluid dynamics and a super fast diagnostic camera

    NASA Astrophysics Data System (ADS)

    Engfer, Christian; Pfüller, Enrico; Wiedemann, Manuel; Wolf, Jürgen; Lutz, Thorsten; Krämer, Ewald; Röser, Hans-Peter

    2012-09-01

    The Stratospheric Observatory for Infrared Astronomy (SOFIA) is a 2.5 m reflecting telescope housed in an open cavity on board of a Boeing 747SP. During observations, the cavity is exposed to transonic flow conditions. The oncoming boundary layer evolves into a free shear layer being responsible for optical aberrations and for aerodynamic and aeroacoustic disturbances within the cavity. While the aero-acoustical excitation of an airborne telescope can be minimized by using passive flow control devices, the aero-optical properties of the flow are difficult to improve. Hence it is important to know how much the image seen through the SOFIA telescope is perturbed by so called seeing effects. Prior to the SOFIA science fights Computational Fluid Dynamics (CFD) simulations using URANS and DES methods were carried out to determine the flow field within and above the cavity and hence in the optical path in order to provide an assessment of the aero-optical properties under baseline conditions. In addition and for validation purposes, out of focus images have been taken during flight with a Super Fast Diagnostic Camera (SFDC). Depending on the binning factor and the sub-array size, the SFDC is able to take and to read out images at very high frame rates. The paper explains the numerical approach based on CFD to evaluate the aero-optical properties of SOFIA. The CFD data is then compared to the high speed images taken by the SFDC during flight.

  15. Development of the FPI+ as facility science instrument for SOFIA cycle four observations

    NASA Astrophysics Data System (ADS)

    Pfüller, Enrico; Wiedemann, Manuel; Wolf, Jürgen; Krabbe, Alfred

    2016-08-01

    The Stratospheric Observatory for Infrared Astronomy (SOFIA) is a heavily modified Boeing 747SP aircraft, accommodating a 2.5m infrared telescope. This airborne observation platform takes astronomers to flight altitudes of up to 13.7 km (45,000ft) and therefore allows an unobstructed view of the infrared universe at wavelengths between 0.3 m and 1600 m. SOFIA is currently completing its fourth cycle of observations and utilizes eight different imaging and spectroscopic science instruments. New instruments for SOFIAs cycle 4 observations are the High-resolution Airborne Wideband Camera-plus (HAWC+) and the Focal Plane Imager (FPI+). The latter is an integral part of the telescope assembly and is used on every SOFIA flight to ensure precise tracking on the desired targets. The FPI+ is used as a visual-light photometer in its role as facility science instrument. Since the upgrade of the FPI camera and electronics in 2013, it uses a thermo-electrically cooled science grade EM-CCD sensor inside a commercial-off-the-shelf Andor camera. The back-illuminated sensor has a peak quantum efficiency of 95% and the dark current is as low as 0.01 e-/pix/sec. With this new hardware the telescope has successfully tracked on 16th magnitude stars and thus the sky coverage, e.g. the area of sky that has suitable tracking stars, has increased to 99%. Before its use as an integrated tracking imager, the same type of camera has been used as a standalone diagnostic tool to analyze the telescope pointing stability at frequencies up to 200 Hz (imaging with 400 fps). These measurements help to improve the telescope pointing control algorithms and therefore reduce the image jitter in the focal plane. Science instruments benefit from this improvement with smaller image sizes for longer exposure times. The FPI has also been used to support astronomical observations like stellar occultations by the dwarf planet Pluto and a number of exoplanet transits. Especially the observation of the occultation events benefits from the high camera sensitivity, fast readout capability and the low read noise and it was possible to achieve high time resolution on the photometric light curves. This paper will give an overview of the development from the standalone diagnostic camera to the upgraded guiding/tracking camera, fully integrated into the telescope, while still offering the diagnostic capabilities and finally to the use as a facility science instrument on SOFIA.

  16. Neutron temporal diagnostic for high-yield deuterium-tritium cryogenic implosions on OMEGA

    DOE PAGES

    Stoeckl, C.; Boni, R.; Ehrne, F.; ...

    2016-05-10

    A next-generation neutron temporal diagnostic (NTD) capable of recording high-quality data for the highest anticipated yield cryogenic DT implosion experiments was recently installed at the Omega Laser Facility. A high-quality measurement of the neutron production width is required to determine the hot-spot pressure achieved in inertial confinement fusion experiments—a key metric in assessing the quality of these implosions. The design of this NTD is based on a fast-rise-time plastic scintillator, which converts the neutron kinetic energy to 350- to 450-nm-wavelength light. The light from the scintillator inside the nose-cone assembly is relayed ~16 m to a streak camera in amore » well-shielded location. An ~200× reduction in neutron background was observed during the first high-yield DT cryogenic implosions compared to the current NTD installation on OMEGA. An impulse response of ~40±10 ps was measured in a dedicated experiment using hard x rays from a planar target irradiated with a 10-ps short pulse from the OMEGA EP laser. Furthermore, the measured instrument response includes contributions from the scintillator rise time, optical relay, and streak camera.« less

  17. Neutron temporal diagnostic for high-yield deuterium–tritium cryogenic implosions on OMEGA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoeckl, C.; Boni, R.; Ehrne, F.

    A next-generation neutron temporal diagnostic (NTD) capable of recording high-quality data for the highest anticipated yield cryogenic deuterium–tritium (DT) implosion experiments was recently installed at the Omega Laser Facility. A high-quality measurement of the neutron production width is required to determine the hot-spot pressure achieved in inertial confinement fusion experiments—a key metric in assessing the quality of these implosions. The design of this NTD is based on a fast-rise-time plastic scintillator, which converts the neutron kinetic energy to 350- to 450-nm-wavelength light. The light from the scintillator inside the nose-cone assembly is relayed ∼16 m to a streak camera inmore » a well-shielded location. An ∼200× reduction in neutron background was observed during the first high-yield DT cryogenic implosions compared to the current NTD installation on OMEGA. An impulse response of ∼40 ± 10 ps was measured in a dedicated experiment using hard x-rays from a planar target irradiated with a 10-ps short pulse from the OMEGA EP laser. The measured instrument response includes contributions from the scintillator rise time, optical relay, and streak camera.« less

  18. Neutron temporal diagnostic for high-yield deuterium-tritium cryogenic implosions on OMEGA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoeckl, C.; Boni, R.; Ehrne, F.

    A next-generation neutron temporal diagnostic (NTD) capable of recording high-quality data for the highest anticipated yield cryogenic DT implosion experiments was recently installed at the Omega Laser Facility. A high-quality measurement of the neutron production width is required to determine the hot-spot pressure achieved in inertial confinement fusion experiments—a key metric in assessing the quality of these implosions. The design of this NTD is based on a fast-rise-time plastic scintillator, which converts the neutron kinetic energy to 350- to 450-nm-wavelength light. The light from the scintillator inside the nose-cone assembly is relayed ~16 m to a streak camera in amore » well-shielded location. An ~200× reduction in neutron background was observed during the first high-yield DT cryogenic implosions compared to the current NTD installation on OMEGA. An impulse response of ~40±10 ps was measured in a dedicated experiment using hard x rays from a planar target irradiated with a 10-ps short pulse from the OMEGA EP laser. Furthermore, the measured instrument response includes contributions from the scintillator rise time, optical relay, and streak camera.« less

  19. Coincidence ion imaging with a fast frame camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Suk Kyoung; Cudry, Fadia; Lin, Yun Fei

    2014-12-15

    A new time- and position-sensitive particle detection system based on a fast frame CMOS (complementary metal-oxide semiconductors) camera is developed for coincidence ion imaging. The system is composed of four major components: a conventional microchannel plate/phosphor screen ion imager, a fast frame CMOS camera, a single anode photomultiplier tube (PMT), and a high-speed digitizer. The system collects the positional information of ions from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of a PMT processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of ion spots onmore » each camera frame with the peak heights on the corresponding time-of-flight spectrum of a PMT. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide.« less

  20. Multi-energy SXR cameras for magnetically confined fusion plasmas (invited)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Delgado-Aparicio, L. F.; Maddox, J.; Pablant, N.

    A compact multi-energy soft x-ray camera has been developed for time, energy and space-resolved measurements of the soft-x-ray emissivity in magnetically confined fusion plasmas. Multi-energy soft x-ray imaging provides a unique opportunity for measuring, simultaneously, a variety of important plasma properties (T e, n Z, ΔZ eff, and n e,fast). The electron temperature can be obtained by modeling the slope of the continuum radiation from ratios of the available brightness and inverted radial emissivity profiles over multiple energy ranges. Impurity density measurements are also possible using the line-emission from medium- to high-Z impurities to separate the background as well asmore » transient levels of metal contributions. As a result, this technique should be explored also as a burning plasma diagnostic in-view of its simplicity and robustness.« less

  1. Multi-energy SXR cameras for magnetically confined fusion plasmas (invited)

    DOE PAGES

    Delgado-Aparicio, L. F.; Maddox, J.; Pablant, N.; ...

    2016-11-14

    A compact multi-energy soft x-ray camera has been developed for time, energy and space-resolved measurements of the soft-x-ray emissivity in magnetically confined fusion plasmas. Multi-energy soft x-ray imaging provides a unique opportunity for measuring, simultaneously, a variety of important plasma properties (T e, n Z, ΔZ eff, and n e,fast). The electron temperature can be obtained by modeling the slope of the continuum radiation from ratios of the available brightness and inverted radial emissivity profiles over multiple energy ranges. Impurity density measurements are also possible using the line-emission from medium- to high-Z impurities to separate the background as well asmore » transient levels of metal contributions. As a result, this technique should be explored also as a burning plasma diagnostic in-view of its simplicity and robustness.« less

  2. Observations of Macroscopic Shocks in the Laboratory

    NASA Astrophysics Data System (ADS)

    Endrizzi, Douglass; Laufman-Wollitzer, Lauren; Clark, Mike; Olson, Joseph; Myers, Rachel; Forest, Cary; Gota, Hiroshi; WiPAL Team; Tri Alpha Energy Team

    2016-10-01

    A magnetized coaxial plasma gun (MCPG) built by Tri Alpha Energy has been installed on the Wisconsin Plasma Astrophysics Lab (WiPAL) vacuum vessel. The MCPG fires a dense (1018m-3) and warm (10-30 eV) compact toroid (CT) at speeds of order 100 km/s. The CT is characterized using B magnetic diagnostics, multi-tip temperature probes, Ion saturation density probes, and a fast Phantom camera. The CT is injected into vacuum field, neutral gas, and plasmas of various beta. Results and evidence for propagating shocks will be presented. This work supported the NSF GRFP under Grant No. DGE-1256259.

  3. Rise time measurement for ultrafast X-ray pulses

    DOEpatents

    Celliers, Peter M [Berkeley, CA; Weber, Franz A [Oakland, CA; Moon, Stephen J [Tracy, CA

    2005-04-05

    A pump-probe scheme measures the rise time of ultrafast x-ray pulses. Conventional high speed x-ray diagnostics (x-ray streak cameras, PIN diodes, diamond PCD devices) do not provide sufficient time resolution to resolve rise times of x-ray pulses on the order of 50 fs or less as they are being produced by modern fast x-ray sources. Here, we are describing a pump-probe technique that can be employed to measure events where detector resolution is insufficient to resolve the event. The scheme utilizes a diamond plate as an x-ray transducer and a p-polarized probe beam.

  4. Rise Time Measurement for Ultrafast X-Ray Pulses

    DOEpatents

    Celliers, Peter M.; Weber, Franz A.; Moon, Stephen J.

    2005-04-05

    A pump-probe scheme measures the rise time of ultrafast x-ray pulses. Conventional high speed x-ray diagnostics (x-ray streak cameras, PIN diodes, diamond PCD devices) do not provide sufficient time resolution to resolve rise times of x-ray pulses on the order of 50 fs or less as they are being produced by modern fast x-ray sources. Here, we are describing a pump-probe technique that can be employed to measure events where detector resolution is insufficient to resolve the event. The scheme utilizes a diamond plate as an x-ray transducer and a p-polarized probe beam.

  5. Design and Calibration of a Dispersive Imaging Spectrometer Adaptor for a Fast IR Camera on NSTX-U

    NASA Astrophysics Data System (ADS)

    Reksoatmodjo, Richard; Gray, Travis; Princeton Plasma Physics Laboratory Team

    2017-10-01

    A dispersive spectrometer adaptor was designed, constructed and calibrated for use on a fast infrared camera employed to measure temperatures on the lower divertor tiles of the NSTX-U tokamak. This adaptor efficiently and evenly filters and distributes long-wavelength infrared photons between 8.0 and 12.0 microns across the 128x128 pixel detector of the fast IR camera. By determining the width of these separated wavelength bands across the camera detector, and then determining the corresponding average photon count for each photon wavelength, a very accurate measurement of the temperature, and thus heat flux, of the divertor tiles can be calculated using Plank's law. This approach of designing an exterior dispersive adaptor for the fast IR camera allows accurate temperature measurements to be made of materials with unknown emissivity. Further, the relative simplicity and affordability of this adaptor design provides an attractive option over more expensive, slower, dispersive IR camera systems. This work was made possible by funding from the Department of Energy for the Summer Undergraduate Laboratory Internship (SULI) program. This work is supported by the US DOE Contract No. DE-AC02-09CH11466.

  6. Coincidence electron/ion imaging with a fast frame camera

    NASA Astrophysics Data System (ADS)

    Li, Wen; Lee, Suk Kyoung; Lin, Yun Fei; Lingenfelter, Steven; Winney, Alexander; Fan, Lin

    2015-05-01

    A new time- and position- sensitive particle detection system based on a fast frame CMOS camera is developed for coincidence electron/ion imaging. The system is composed of three major components: a conventional microchannel plate (MCP)/phosphor screen electron/ion imager, a fast frame CMOS camera and a high-speed digitizer. The system collects the positional information of ions/electrons from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of MCPs processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of electron/ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide. We further show that a time resolution of 30 ps can be achieved when measuring electron TOF spectrum and this enables the new system to achieve a good energy resolution along the TOF axis.

  7. Simulation of a tangential soft x-ray imaging system.

    PubMed

    Battaglia, D J; Shafer, M W; Unterberg, E A; Bell, R E; Hillis, D L; LeBlanc, B P; Maingi, R; Sabbagh, S; Stratton, B C

    2010-10-01

    Tangentially viewing soft x-ray (SXR) cameras are capable of detecting nonaxisymmetric plasma structures in magnetically confined plasmas. They are particularly useful for studying stationary perturbations or phenomenon that occur on a timescale faster than the plasma rotation period. Tangential SXR camera diagnostics are planned for the DIII-D and NSTX tokamaks to elucidate the static edge magnetic structure during the application of 3D perturbations. To support the design of the proposed diagnostics, a synthetic diagnostic model was developed using the CHIANTI database to estimate the SXR emission. The model is shown to be in good agreement with the measurements from an existing tangential SXR camera diagnostic on NSTX.

  8. Spectroscopic interpretation and velocimetry analysis of fluctuations in a cylindrical plasma recorded by a fast camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oldenbuerger, S.; Brandt, C.; Brochard, F.

    2010-06-15

    Fast visible imaging is used on a cylindrical magnetized argon plasma produced by thermionic discharge in the Mirabelle device. To link the information collected with the camera to a physical quantity, fast camera movies of plasma structures are compared to Langmuir probe measurements. High correlation is found between light fluctuations and plasma density fluctuations. Contributions from neutral argon and ionized argon to the overall light intensity are separated by using interference filters and a light intensifier. Light emitting transitions are shown to involve a metastable neutral argon state that can be excited by thermal plasma electrons, thus explaining the goodmore » correlation between light and density fluctuations. The propagation velocity of plasma structures is calculated by adapting velocimetry methods to the fast camera movies. The resulting estimates of instantaneous propagation velocity are in agreement with former experiments. The computation of mean velocities is discussed.« less

  9. Spectroscopic interpretation and velocimetry analysis of fluctuations in a cylindrical plasma recorded by a fast camera

    NASA Astrophysics Data System (ADS)

    Oldenbürger, S.; Brandt, C.; Brochard, F.; Lemoine, N.; Bonhomme, G.

    2010-06-01

    Fast visible imaging is used on a cylindrical magnetized argon plasma produced by thermionic discharge in the Mirabelle device. To link the information collected with the camera to a physical quantity, fast camera movies of plasma structures are compared to Langmuir probe measurements. High correlation is found between light fluctuations and plasma density fluctuations. Contributions from neutral argon and ionized argon to the overall light intensity are separated by using interference filters and a light intensifier. Light emitting transitions are shown to involve a metastable neutral argon state that can be excited by thermal plasma electrons, thus explaining the good correlation between light and density fluctuations. The propagation velocity of plasma structures is calculated by adapting velocimetry methods to the fast camera movies. The resulting estimates of instantaneous propagation velocity are in agreement with former experiments. The computation of mean velocities is discussed.

  10. Imaging diagnostics of pulsed plasma discharges in saline generated with various sharp pin powered electrodes

    NASA Astrophysics Data System (ADS)

    Asimakoulas, L.; Karim, M. L.; Dostal, L.; Krcma, F.; Graham, W. G.; Field, T. A.

    2016-09-01

    Plasmas formed by 1 ms pulses of between 180 and 300 V applied to sharp pin-like electrodes immersed in saline solution have been imaged with a Photron SA-X2 fast framing camera and an Andor iStar 510 ICCD camera. Stainless steel, Tungsten and Gold electrodes were investigated with tip diameters of 30 μm, 1 μm and < 1 μ m respectively. As previously observed, a vapour layer forms around the electrode prior to plasma ignition. For gold and stainless steel lower voltages were required to minimize electrode damage. Preliminary anlaysis indicates at lower voltages for all tips the fast framing results show that light emission is normally centred on a single small volume, which appears to move about, but remains close to the tip. In the case of Tungsten with higher voltages or longer pulses the tip of the needle can heat up to incandescent temperatures. At higher voltages shock wave fronts appear to be observed as the vapour layer collapses at the end of the voltage pulse. Backlighting and no lighting to observe bubble/vapour layer formation and emission due to plasma formation were employed. Sometimes at higher voltages a thicker vapour layer engulfs the tip and no plasma emission/current is observed.

  11. The application of high-speed photography in z-pinch high-temperature plasma diagnostics

    NASA Astrophysics Data System (ADS)

    Wang, Kui-lu; Qiu, Meng-tong; Hei, Dong-wei

    2007-01-01

    This invited paper is presented to discuss the application of high speed photography in z-pinch high temperature plasma diagnostics in recent years in Northwest Institute of Nuclear Technology in concentrative mode. The developments and applications of soft x-ray framing camera, soft x-ray curved crystal spectrometer, optical framing camera, ultraviolet four-frame framing camera and ultraviolet-visible spectrometer are introduced.

  12. Synthetic neutron camera and spectrometer in JET based on AFSI-ASCOT simulations

    NASA Astrophysics Data System (ADS)

    Sirén, P.; Varje, J.; Weisen, H.; Koskela, T.; contributors, JET

    2017-09-01

    The ASCOT Fusion Source Integrator (AFSI) has been used to calculate neutron production rates and spectra corresponding to the JET 19-channel neutron camera (KN3) and the time-of-flight spectrometer (TOFOR) as ideal diagnostics, without detector-related effects. AFSI calculates fusion product distributions in 4D, based on Monte Carlo integration from arbitrary reactant distribution functions. The distribution functions were calculated by the ASCOT Monte Carlo particle orbit following code for thermal, NBI and ICRH particle reactions. Fusion cross-sections were defined based on the Bosch-Hale model and both DD and DT reactions have been included. Neutrons generated by AFSI-ASCOT simulations have already been applied as a neutron source of the Serpent neutron transport code in ITER studies. Additionally, AFSI has been selected to be a main tool as the fusion product generator in the complete analysis calculation chain: ASCOT - AFSI - SERPENT (neutron and gamma transport Monte Carlo code) - APROS (system and power plant modelling code), which encompasses the plasma as an energy source, heat deposition in plant structures as well as cooling and balance-of-plant in DEMO applications and other reactor relevant analyses. This conference paper presents the first results and validation of the AFSI DD fusion model for different auxiliary heating scenarios (NBI, ICRH) with very different fast particle distribution functions. Both calculated quantities (production rates and spectra) have been compared with experimental data from KN3 and synthetic spectrometer data from ControlRoom code. No unexplained differences have been observed. In future work, AFSI will be extended for synthetic gamma diagnostics and additionally, AFSI will be used as part of the neutron transport calculation chain to model real diagnostics instead of ideal synthetic diagnostics for quantitative benchmarking.

  13. Enhanced visible and near-infrared capabilities of the JET mirror-linked divertor spectroscopy system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lomanowski, B. A., E-mail: b.a.lomanowski@durham.ac.uk; Sharples, R. M.; Meigs, A. G.

    2014-11-15

    The mirror-linked divertor spectroscopy diagnostic on JET has been upgraded with a new visible and near-infrared grating and filtered spectroscopy system. New capabilities include extended near-infrared coverage up to 1875 nm, capturing the hydrogen Paschen series, as well as a 2 kHz frame rate filtered imaging camera system for fast measurements of impurity (Be II) and deuterium Dα, Dβ, Dγ line emission in the outer divertor. The expanded system provides unique capabilities for studying spatially resolved divertor plasma dynamics at near-ELM resolved timescales as well as a test bed for feasibility assessment of near-infrared spectroscopy.

  14. Sub-millisecond electron density profile measurement at the JET tokamak with the fast lithium beam emission spectroscopy system

    NASA Astrophysics Data System (ADS)

    Réfy, D. I.; Brix, M.; Gomes, R.; Tál, B.; Zoletnik, S.; Dunai, D.; Kocsis, G.; Kálvin, S.; Szabolics, T.; JET Contributors

    2018-04-01

    Diagnostic alkali atom (e.g., lithium) beams are routinely used to diagnose magnetically confined plasmas, namely, to measure the plasma electron density profile in the edge and the scrape off layer region. A light splitting optics system was installed into the observation system of the lithium beam emission spectroscopy diagnostic at the Joint European Torus (JET) tokamak, which allows simultaneous measurement of the beam light emission with a spectrometer and a fast avalanche photodiode (APD) camera. The spectrometer measurement allows density profile reconstruction with ˜10 ms time resolution, absolute position calculation from the Doppler shift, spectral background subtraction as well as relative intensity calibration of the channels for each discharge. The APD system is capable of measuring light intensities on the microsecond time scale. However ˜100 μs integration is needed to have an acceptable signal to noise ratio due to moderate light levels. Fast modulation of the beam up to 30 kHz is implemented which allows background subtraction on the 100 μs time scale. The measurement covers the 0.9 < ρpol < 1.1 range with 6-10 mm optical resolution at the measurement location which translates to 3-5 mm radial resolution at the midplane due to flux expansion. An automated routine has been developed which performs the background subtraction, the relative calibration, and the comprehensive error calculation, runs a Bayesian density reconstruction code, and loads results to the JET database. The paper demonstrates the capability of the APD system by analyzing fast phenomena like pellet injection and edge localized modes.

  15. Demonstration of a real-time interferometer as a bunch-length monitor in a high-current electron beam accelerator.

    PubMed

    Thangaraj, J; Andonian, G; Thurman-Keup, R; Ruan, J; Johnson, A S; Lumpkin, A; Santucci, J; Maxwell, T; Murokh, A; Ruelas, M; Ovodenko, A

    2012-04-01

    A real-time interferometer (RTI) has been developed to monitor the bunch length of an electron beam in an accelerator. The RTI employs spatial autocorrelation, reflective optics, and a fast response pyro-detector array to obtain a real-time autocorrelation trace of the coherent radiation from an electron beam thus providing the possibility of online bunch-length diagnostics. A complete RTI system has been commissioned at the A0 photoinjector facility to measure sub-mm bunches at 13 MeV. Bunch length variation (FWHM) between 0.8 ps (~0.24 mm) and 1.5 ps (~0.45 mm) has been measured and compared with a Martin-Puplett interferometer and a streak camera. The comparisons show that RTI is a viable, complementary bunch length diagnostic for sub-mm electron bunches. © 2012 American Institute of Physics

  16. Diagnostics of thermal spraying plasma jets

    NASA Astrophysics Data System (ADS)

    Fauchais, P.; Coudert, J. F.; Vardelle, M.; Vardelle, A.; Denoirjean, A.

    1992-06-01

    The development of diagnostic techniques for dc plasma spraying is reviewed with attention given to the need for thick highly reproducible coatings of good quality for aeronautic and other uses. Among the techniques examined are fast cameras, laser-Doppler anemometry (LDA), coherent anti-Stokes Raman spectroscopy (CARS), enthalpy probes, and emission spectroscopy. Particular emphasis is given to the effect of arc fluctuations on the spectroscopic measurements, and a method is introduced for obtaining temperature and species density of vapor clouds traveling with each particle in flight. Coating properties can be deduced from data on single particles, and statistical approaches are often unreliable without added data on surface temperature and particle velocity. Also presented is a method for deriving the temperature evolution of a cooled splat and successive layers and passes. These methods are of interest to the control of adhesion and cohesion in coatings for critical aerospace applications.

  17. Demonstration of a real-time interferometer as a bunch-lenght monitor in a high-current electron beam accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thangaraj, J.; Thurman-Keup, R.; Ruan, J.

    2012-03-01

    A real-time interferometer (RTI) has been developed to monitor the bunch length of an electron beam in an accelerator. The RTI employs spatial autocorrelation, reflective optics, and a fast response pyro-detector array to obtain a real-time autocorrelation trace of the coherent radiation from an electron beam thus providing the possibility of online bunch-length diagnostics. A complete RTI system has been commissioned at the A0 photoinjector facility to measure sub-mm bunches at 13 MeV. Bunch length variation (FWHM) between 0.8 ps (-0.24 mm) and 1.5 ps (-0.45 mm) has been measured and compared with a Martin-Puplett interferometer and a streak camera.more » The comparisons show that RTI is a viable, complementary bunch length diagnostic for sub-mm electron bunches.« less

  18. Demonstration of a real-time interferometer as a bunch-length monitor in a high-current electron beam accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thangaraj, J.; Thurman-Keup, R.; Ruan, J.

    2012-04-15

    A real-time interferometer (RTI) has been developed to monitor the bunch length of an electron beam in an accelerator. The RTI employs spatial autocorrelation, reflective optics, and a fast response pyro-detector array to obtain a real-time autocorrelation trace of the coherent radiation from an electron beam thus providing the possibility of online bunch-length diagnostics. A complete RTI system has been commissioned at the A0 photoinjector facility to measure sub-mm bunches at 13 MeV. Bunch length variation (FWHM) between 0.8 ps ({approx}0.24 mm) and 1.5 ps ({approx}0.45 mm) has been measured and compared with a Martin-Puplett interferometer and a streak camera.more » The comparisons show that RTI is a viable, complementary bunch length diagnostic for sub-mm electron bunches.« less

  19. Fast and compact internal scanning CMOS-based hyperspectral camera: the Snapscan

    NASA Astrophysics Data System (ADS)

    Pichette, Julien; Charle, Wouter; Lambrechts, Andy

    2017-02-01

    Imec has developed a process for the monolithic integration of optical filters on top of CMOS image sensors, leading to compact, cost-efficient and faster hyperspectral cameras. Linescan cameras are typically used in remote sensing or for conveyor belt applications. Translation of the target is not always possible for large objects or in many medical applications. Therefore, we introduce a novel camera, the Snapscan (patent pending), exploiting internal movement of a linescan sensor enabling fast and convenient acquisition of high-resolution hyperspectral cubes (up to 2048x3652x150 in spectral range 475-925 nm). The Snapscan combines the spectral and spatial resolutions of a linescan system with the convenience of a snapshot camera.

  20. SCOUT: a fast Monte-Carlo modeling tool of scintillation camera output†

    PubMed Central

    Hunter, William C J; Barrett, Harrison H.; Muzi, John P.; McDougald, Wendy; MacDonald, Lawrence R.; Miyaoka, Robert S.; Lewellen, Thomas K.

    2013-01-01

    We have developed a Monte-Carlo photon-tracking and readout simulator called SCOUT to study the stochastic behavior of signals output from a simplified rectangular scintillation-camera design. SCOUT models the salient processes affecting signal generation, transport, and readout of a scintillation camera. Presently, we compare output signal statistics from SCOUT to experimental results for both a discrete and a monolithic camera. We also benchmark the speed of this simulation tool and compare it to existing simulation tools. We find this modeling tool to be relatively fast and predictive of experimental results. Depending on the modeled camera geometry, we found SCOUT to be 4 to 140 times faster than other modeling tools. PMID:23640136

  1. Modified slanted-edge method for camera modulation transfer function measurement using nonuniform fast Fourier transform technique

    NASA Astrophysics Data System (ADS)

    Duan, Yaxuan; Xu, Songbo; Yuan, Suochao; Chen, Yongquan; Li, Hongguang; Da, Zhengshang; Gao, Limin

    2018-01-01

    ISO 12233 slanted-edge method experiences errors using fast Fourier transform (FFT) in the camera modulation transfer function (MTF) measurement due to tilt angle errors in the knife-edge resulting in nonuniform sampling of the edge spread function (ESF). In order to resolve this problem, a modified slanted-edge method using nonuniform fast Fourier transform (NUFFT) for camera MTF measurement is proposed. Theoretical simulations for images with noise at a different nonuniform sampling rate of ESF are performed using the proposed modified slanted-edge method. It is shown that the proposed method successfully eliminates the error due to the nonuniform sampling of the ESF. An experimental setup for camera MTF measurement is established to verify the accuracy of the proposed method. The experiment results show that under different nonuniform sampling rates of ESF, the proposed modified slanted-edge method has improved accuracy for the camera MTF measurement compared to the ISO 12233 slanted-edge method.

  2. View of the Columbia's remote manipulator system

    NASA Image and Video Library

    1982-03-30

    STS003-09-444 (22-30 March 1982) --- The darkness of space provides the backdrop for this scene of the plasma diagnostics package (PDR) experiment in the grasp of the end effector or ?hand? of the remote manipulator system (RMS) arm, and other components of the Office of Space Sciences (OSS-1) package in the aft section of the Columbia?s cargo hold. The PDP is a compact, comprehensive assembly of electromagnetic and particle sensors that will be used to study the interaction of the orbiter with its surrounding environment; to test the capabilities of the shuttle?s remote manipulator system; and to carry out experiments in conjunction with the fast pulse electron generator of the vehicle charging and potential experiment, another experiment on the OSS-1 payload pallet. This photograph was exposed with a 70mm handheld camera by the astronaut crew of STS-3, with a handheld camera aimed through the flight deck?s aft window. Photo credit: NASA

  3. Real-time tracking and fast retrieval of persons in multiple surveillance cameras of a shopping mall

    NASA Astrophysics Data System (ADS)

    Bouma, Henri; Baan, Jan; Landsmeer, Sander; Kruszynski, Chris; van Antwerpen, Gert; Dijk, Judith

    2013-05-01

    The capability to track individuals in CCTV cameras is important for e.g. surveillance applications at large areas such as train stations, airports and shopping centers. However, it is laborious to track and trace people over multiple cameras. In this paper, we present a system for real-time tracking and fast interactive retrieval of persons in video streams from multiple static surveillance cameras. This system is demonstrated in a shopping mall, where the cameras are positioned without overlapping fields-of-view and have different lighting conditions. The results show that the system allows an operator to find the origin or destination of a person more efficiently. The misses are reduced with 37%, which is a significant improvement.

  4. Evaluation of a miniature microscope objective designed for fluorescence array microscopy detection of Mycobacterium tuberculosis.

    PubMed

    McCall, Brian; Olsen, Randall J; Nelles, Nicole J; Williams, Dawn L; Jackson, Kevin; Richards-Kortum, Rebecca; Graviss, Edward A; Tkaczyk, Tomasz S

    2014-03-01

    A prototype miniature objective that was designed for a point-of-care diagnostic array microscope for detection of Mycobacterium tuberculosis and previously fabricated and presented in a proof of concept is evaluated for its effectiveness in detecting acid-fast bacteria. To evaluate the ability of the microscope to resolve submicron features and details in the image of acid-fast microorganisms stained with a fluorescent dye, and to evaluate the accuracy of clinical diagnoses made with digital images acquired with the objective. The lens prescription data for the microscope design are presented. A test platform is built by combining parts of a standard microscope, a prototype objective, and a digital single-lens reflex camera. Counts of acid-fast bacteria made with the prototype objective are compared to counts obtained with a standard microscope over matched fields of view. Two sets of 20 smears, positive and negative, are diagnosed by 2 pathologists as sputum smear positive or sputum smear negative, using both a standard clinical microscope and the prototype objective under evaluation. The results are compared to a reference diagnosis of the same sample. More bacteria are counted in matched fields of view in digital images taken with the prototype objective than with the standard clinical microscope. All diagnostic results are found to be highly concordant. An array microscope built with this miniature lens design will be able to detect M tuberculosis with high sensitivity and specificity.

  5. 21 CFR 886.1120 - Opthalmic camera.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1120 Opthalmic camera. (a) Identification. An ophthalmic camera is an AC-powered device intended to take photographs of the eye and the surrounding area...

  6. Ultra-fast framing camera tube

    DOEpatents

    Kalibjian, Ralph

    1981-01-01

    An electronic framing camera tube features focal plane image dissection and synchronized restoration of the dissected electron line images to form two-dimensional framed images. Ultra-fast framing is performed by first streaking a two-dimensional electron image across a narrow slit, thereby dissecting the two-dimensional electron image into sequential electron line images. The dissected electron line images are then restored into a framed image by a restorer deflector operated synchronously with the dissector deflector. The number of framed images on the tube's viewing screen is equal to the number of dissecting slits in the tube. The distinguishing features of this ultra-fast framing camera tube are the focal plane dissecting slits, and the synchronously-operated restorer deflector which restores the dissected electron line images into a two-dimensional framed image. The framing camera tube can produce image frames having high spatial resolution of optical events in the sub-100 picosecond range.

  7. Design and realization of an AEC&AGC system for the CCD aerial camera

    NASA Astrophysics Data System (ADS)

    Liu, Hai ying; Feng, Bing; Wang, Peng; Li, Yan; Wei, Hao yun

    2015-08-01

    An AEC and AGC(Automatic Exposure Control and Automatic Gain Control) system was designed for a CCD aerial camera with fixed aperture and electronic shutter. The normal AEC and AGE algorithm is not suitable to the aerial camera since the camera always takes high-resolution photographs in high-speed moving. The AEC and AGE system adjusts electronic shutter and camera gain automatically according to the target brightness and the moving speed of the aircraft. An automatic Gamma correction is used before the image is output so that the image is better for watching and analyzing by human eyes. The AEC and AGC system could avoid underexposure, overexposure, or image blurring caused by fast moving or environment vibration. A series of tests proved that the system meet the requirements of the camera system with its fast adjusting speed, high adaptability, high reliability in severe complex environment.

  8. Flow visualization by mobile phone cameras

    NASA Astrophysics Data System (ADS)

    Cierpka, Christian; Hain, Rainer; Buchmann, Nicolas A.

    2016-06-01

    Mobile smart phones were completely changing people's communication within the last ten years. However, these devices do not only offer communication through different channels but also devices and applications for fun and recreation. In this respect, mobile phone cameras include now relatively fast (up to 240 Hz) cameras to capture high-speed videos of sport events or other fast processes. The article therefore explores the possibility to make use of this development and the wide spread availability of these cameras in the terms of velocity measurements for industrial or technical applications and fluid dynamics education in high schools and at universities. The requirements for a simplistic PIV (particle image velocimetry) system are discussed. A model experiment of a free water jet was used to prove the concept and shed some light on the achievable quality and determine bottle necks by comparing the results obtained with a mobile phone camera with data taken by a high-speed camera suited for scientific experiments.

  9. SCOUT: A Fast Monte-Carlo Modeling Tool of Scintillation Camera Output

    PubMed Central

    Hunter, William C. J.; Barrett, Harrison H.; Lewellen, Thomas K.; Miyaoka, Robert S.; Muzi, John P.; Li, Xiaoli; McDougald, Wendy; MacDonald, Lawrence R.

    2011-01-01

    We have developed a Monte-Carlo photon-tracking and readout simulator called SCOUT to study the stochastic behavior of signals output from a simplified rectangular scintillation-camera design. SCOUT models the salient processes affecting signal generation, transport, and readout. Presently, we compare output signal statistics from SCOUT to experimental results for both a discrete and a monolithic camera. We also benchmark the speed of this simulation tool and compare it to existing simulation tools. We find this modeling tool to be relatively fast and predictive of experimental results. Depending on the modeled camera geometry, we found SCOUT to be 4 to 140 times faster than other modeling tools. PMID:22072297

  10. Progress in diagnostics of the COMPASS tokamak

    NASA Astrophysics Data System (ADS)

    Weinzettl, V.; Adamek, J.; Berta, M.; Bilkova, P.; Bogar, O.; Bohm, P.; Cavalier, J.; Dejarnac, R.; Dimitrova, M.; Ficker, O.; Fridrich, D.; Grover, O.; Hacek, P.; Havlicek, J.; Havranek, A.; Horacek, J.; Hron, M.; Imrisek, M.; Komm, M.; Kovarik, K.; Krbec, J.; Markovic, T.; Matveeva, E.; Mitosinkova, K.; Mlynar, J.; Naydenkova, D.; Panek, R.; Paprok, R.; Peterka, M.; Podolnik, A.; Seidl, J.; Sos, M.; Stockel, J.; Tomes, M.; Varavin, M.; Varju, J.; Vlainic, M.; Vondracek, P.; Zajac, J.; Zacek, F.; Stano, M.; Anda, G.; Dunai, D.; Krizsanoczi, T.; Refy, D.; Zoletnik, S.; Silva, A.; Gomes, R.; Pereira, T.; Popov, Tsv.; Sarychev, D.; Ermak, G. P.; Zebrowski, J.; Jakubowski, M.; Rabinski, M.; Malinowski, K.; Nanobashvili, S.; Spolaore, M.; Vianello, N.; Gauthier, E.; Gunn, J. P.; Devitre, A.

    2017-12-01

    The COMPASS tokamak at IPP Prague is a small-size device with an ITER-relevant plasma geometry and operating in both the Ohmic as well as neutral beam assisted H-modes since 2012. A basic set of diagnostics installed at the beginning of the COMPASS operation has been gradually broadened in type of diagnostics, extended in number of detectors and collected channels and improved by an increased data acquisition speed. In recent years, a significant progress in diagnostic development has been motivated by the improved COMPASS plasma performance and broadening of its scientific programme (L-H transition and pedestal scaling studies, magnetic perturbations, runaway electron control and mitigation, plasma-surface interaction and corresponding heat fluxes, Alfvenic and edge localized mode observations, disruptions, etc.). In this contribution, we describe major upgrades of a broad spectrum of the COMPASS diagnostics and discuss their potential for physical studies. In particular, scrape-off layer plasma diagnostics will be represented by a new concept for microsecond electron temperature and heat flux measurements - we introduce a new set of divertor Langmuir and ball-pen probe arrays, newly constructed probe heads for reciprocating manipulators as well as several types of standalone probes. Among optical tools, an upgraded high-resolution edge Thomson scattering diagnostic for pedestal studies and a set of new visible light and infrared (plasma-surface interaction investigations) cameras will be described. Particle and beam diagnostics will be covered by a neutral particle analyzer, diagnostics on a lithium beam, Cherenkov detectors (for a direct detection of runaway electrons) and neutron detectors. We also present new modifications of the microwave reflectometer for fast edge density profile measurements.

  11. Fast Resistive Bolometry

    NASA Astrophysics Data System (ADS)

    Graham, Jeffrey

    2005-10-01

    A bolometer with microsecond scale response time is under construction for the Caltech spheromak experiment to measure radiation from a ˜20 μs duration plasma discharge emitting ˜10^2---10^3 kW/m^2. A gold film several micrometers thick absorbs the radiation, heats up, and the consequent change in resistance can be measured. The film itself is vacuum deposited upon a glass slide. Several geometries for the film are under consideration to optimize the amount of radiation absorbed, the response time and the signal-to-noise ratio. We measure the change in voltage across the film for a known current driven through it; a square pulse (3---30A, ˜20 μs) is used to avoid Joule heating. Results from prototypes tested with a UV flashlamp will be presented. After optimizing the bolometer design, the final vacuum-compatible diagnostic would consist of a plasma-facing bolometer and a reference in a camera obscura. This device could provide a design for fast resistive bolometry.

  12. An Efficient Pipeline Wavefront Phase Recovery for the CAFADIS Camera for Extremely Large Telescopes

    PubMed Central

    Magdaleno, Eduardo; Rodríguez, Manuel; Rodríguez-Ramos, José Manuel

    2010-01-01

    In this paper we show a fast, specialized hardware implementation of the wavefront phase recovery algorithm using the CAFADIS camera. The CAFADIS camera is a new plenoptic sensor patented by the Universidad de La Laguna (Canary Islands, Spain): international patent PCT/ES2007/000046 (WIPO publication number WO/2007/082975). It can simultaneously measure the wavefront phase and the distance to the light source in a real-time process. The pipeline algorithm is implemented using Field Programmable Gate Arrays (FPGA). These devices present architecture capable of handling the sensor output stream using a massively parallel approach and they are efficient enough to resolve several Adaptive Optics (AO) problems in Extremely Large Telescopes (ELTs) in terms of processing time requirements. The FPGA implementation of the wavefront phase recovery algorithm using the CAFADIS camera is based on the very fast computation of two dimensional fast Fourier Transforms (FFTs). Thus we have carried out a comparison between our very novel FPGA 2D-FFTa and other implementations. PMID:22315523

  13. An efficient pipeline wavefront phase recovery for the CAFADIS camera for extremely large telescopes.

    PubMed

    Magdaleno, Eduardo; Rodríguez, Manuel; Rodríguez-Ramos, José Manuel

    2010-01-01

    In this paper we show a fast, specialized hardware implementation of the wavefront phase recovery algorithm using the CAFADIS camera. The CAFADIS camera is a new plenoptic sensor patented by the Universidad de La Laguna (Canary Islands, Spain): international patent PCT/ES2007/000046 (WIPO publication number WO/2007/082975). It can simultaneously measure the wavefront phase and the distance to the light source in a real-time process. The pipeline algorithm is implemented using Field Programmable Gate Arrays (FPGA). These devices present architecture capable of handling the sensor output stream using a massively parallel approach and they are efficient enough to resolve several Adaptive Optics (AO) problems in Extremely Large Telescopes (ELTs) in terms of processing time requirements. The FPGA implementation of the wavefront phase recovery algorithm using the CAFADIS camera is based on the very fast computation of two dimensional fast Fourier Transforms (FFTs). Thus we have carried out a comparison between our very novel FPGA 2D-FFTa and other implementations.

  14. Initial operation of the Lockheed Martin T4B experiment

    NASA Astrophysics Data System (ADS)

    Garrett, M. L.; Blinzer, A.; Ebersohn, F.; Gucker, S.; Heinrich, J.; Lohff, C.; McGuire, T.; Montecalvo, N.; Raymond, A.; Rhoads, J.; Ross, P.; Sommers, B.; Strandberg, E.; Sullivan, R.; Walker, J.

    2017-10-01

    The T4B experiment is a linear, encapsulated ring cusp confinement device, designed to develop a physics and technology basis for a follow-on high beta (β 1) machine. The experiment consists of 13 magnetic field coils (11 external, 2 internal), to produce a series of on-axis field nulls surrounded by modest magnetic fields of up to 0.3 T. The primary plasma source used on T4B is a lanthanum hexaboride (LaB6) cathode, capable of coupling over 100 kW into the plasma. Initial testing focused on commissioning of components and integration of diagnostics. Diagnostics include both long and short wavelength interferometry, bolometry, visible and X-ray spectroscopy, Langmuir and B-dot probes, Thomson scattering, flux loops, and fast camera imagery. Low energy discharges were used to begin validation of physics models and simulation efforts. Following the initial machine check-out, neutral beam injection (NBI) was integrated onto the device. Detailed results will be presented. 2017 Lockheed Martin Corporation. All Rights Reserved.

  15. Easily Accessible Camera Mount

    NASA Technical Reports Server (NTRS)

    Chalson, H. E.

    1986-01-01

    Modified mount enables fast alinement of movie cameras in explosionproof housings. Screw on side and readily reached through side door of housing. Mount includes right-angle drive mechanism containing two miter gears that turn threaded shaft. Shaft drives movable dovetail clamping jaw that engages fixed dovetail plate on camera. Mechanism alines camera in housing and secures it. Reduces installation time by 80 percent.

  16. Double and Multiple Star Measurements at the Southern Sky with a 50cm-Cassegrain and a Fast CCD Camera in 2008

    NASA Astrophysics Data System (ADS)

    Anton, Rainer

    2011-04-01

    Using a 50cm Cassegrain in Namibia, recordings of double and multiple stars were made with a fast CCD camera and a notebook computer. From superpositions of "lucky images", measurements of 149 systems were obtained and compared with literature data. B/W and color images of some remarkable systems are also presented.

  17. Double and Multiple Star Measurements in the Northern Sky with a 10" Newtonian and a Fast CCD Camera in 2006 through 2009

    NASA Astrophysics Data System (ADS)

    Anton, Rainer

    2010-07-01

    Using a 10" Newtonian and a fast CCD camera, recordings of double and multiple stars were made at high frame rates with a notebook computer. From superpositions of "lucky images", measurements of 139 systems were obtained and compared with literature data. B/w and color images of some noteworthy systems are also presented.

  18. Motion-Blur-Free High-Speed Video Shooting Using a Resonant Mirror

    PubMed Central

    Inoue, Michiaki; Gu, Qingyi; Takaki, Takeshi; Ishii, Idaku; Tajima, Kenji

    2017-01-01

    This study proposes a novel concept of actuator-driven frame-by-frame intermittent tracking for motion-blur-free video shooting of fast-moving objects. The camera frame and shutter timings are controlled for motion blur reduction in synchronization with a free-vibration-type actuator vibrating with a large amplitude at hundreds of hertz so that motion blur can be significantly reduced in free-viewpoint high-frame-rate video shooting for fast-moving objects by deriving the maximum performance of the actuator. We develop a prototype of a motion-blur-free video shooting system by implementing our frame-by-frame intermittent tracking algorithm on a high-speed video camera system with a resonant mirror vibrating at 750 Hz. It can capture 1024 × 1024 images of fast-moving objects at 750 fps with an exposure time of 0.33 ms without motion blur. Several experimental results for fast-moving objects verify that our proposed method can reduce image degradation from motion blur without decreasing the camera exposure time. PMID:29109385

  19. 21 CFR 892.1620 - Cine or spot fluorographic x-ray camera.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cine or spot fluorographic x-ray camera. 892.1620... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1620 Cine or spot fluorographic x-ray camera. (a) Identification. A cine or spot fluorographic x-ray camera is a device intended to photograph...

  20. 21 CFR 892.1620 - Cine or spot fluorographic x-ray camera.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cine or spot fluorographic x-ray camera. 892.1620... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1620 Cine or spot fluorographic x-ray camera. (a) Identification. A cine or spot fluorographic x-ray camera is a device intended to photograph...

  1. 21 CFR 892.1620 - Cine or spot fluorographic x-ray camera.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cine or spot fluorographic x-ray camera. 892.1620... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1620 Cine or spot fluorographic x-ray camera. (a) Identification. A cine or spot fluorographic x-ray camera is a device intended to photograph...

  2. 21 CFR 892.1620 - Cine or spot fluorographic x-ray camera.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cine or spot fluorographic x-ray camera. 892.1620... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1620 Cine or spot fluorographic x-ray camera. (a) Identification. A cine or spot fluorographic x-ray camera is a device intended to photograph...

  3. 21 CFR 892.1620 - Cine or spot fluorographic x-ray camera.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cine or spot fluorographic x-ray camera. 892.1620... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1620 Cine or spot fluorographic x-ray camera. (a) Identification. A cine or spot fluorographic x-ray camera is a device intended to photograph...

  4. Diagnostics for Magnetically Driven Implosions on the 1-MA MAIZE Facility

    NASA Astrophysics Data System (ADS)

    Campbell, Paul; Yager-Elorriaga, David; Miller, Stephanie; Woolstrum, Jeff; Jones, Michael; Jordan, Nicholas; Lau, Y. Y.; Gilgenbach, Ronald; McBride, Ryan

    2017-10-01

    The Michigan Accelerator for Inductive Z-pinch Experiments (MAIZE) is a 3-m-diameter Linear Transformer Driver (LTD) at the University of Michigan which supplies a fast electrical pulse (0-1 MA in 100 ns, for matched loads) to various experimental configurations. In order to better investigate these loads, new diagnostics are being developed. First, an EUV/XUV micro-channel plate pinhole camera and a UV laser imaging system are being implemented to better observe the instability structures that form during implosions. Second, an x-pinch radiography diagnostic is being developed to probe deeper into the plasma loads. Third, Rogowski coils are being developed for enhanced load current measurements. Finally, a bolometry system and photo-conducting diamond (PCD) detectors will be implemented to measure x-ray power and energy. These new systems, combined with the existing twelve-frame laser shadowgraphy, and b-dot current monitors, will be powerful tools for the investigation of imploding z-pinch experiments. This research was supported by the DOE through award DE-SC0012328, Sandia National Laboratories contract DE-NA0003525, the National Science Foundation, and a Nuclear Regulatory Commission new-faculty development Grant. D.Y.E. was supported by an NSF fello.

  5. Progress in neutron-, X-ray- and VIS spectroscopic diagnostics of large-scale plasma focus experiments at ICDMP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidt, Hellmut

    Substantial progress has been made in various diagnostics for investigating results of experiments during the last years performed with the PF1000 device at IPPLM, Warsaw, Poland. In addition to standard diagnostics of the electrical characteristics of up to 1 MJ discharges in a Mather type plasma focus geometry, such as high speed photography, X-ray, fast electron beam and time-integrated neutron measurements, there have been made among others at least three quite successful efforts recently: 1) Setting up of a neutron time-of-flight line with up to five scintillation detectors including optical fibre based data collection equipment, 2) Use of a Mechellemore » spectrometer with CCD registration and possibility to take time-resolved spectra with resolutions down to 100 ns and 3) Setting up and using pinhole cameras equipped with solid state nuclear track detectors for the detection of fusion generated protons. Correlations of emission events as well as plasma and electrical current dynamics are investigated. Neutron emission characteristics and fusion products production mechanisms are discussed considering a generalized beam target model, called Gyrating Particle Model.« less

  6. Double Star Measurements at the Southern Sky with 50 cm Reflectors and Fast CCD Cameras in 2012

    NASA Astrophysics Data System (ADS)

    Anton, Rainer

    2014-07-01

    A Cassegrain and a Ritchey-Chrétien reflector, both with 50 cm aperture, were used in Namibia for recordings of double stars with fast CCD cameras and a notebook computer. From superposition of "lucky images", measurements of 39 double and multiple systems were obtained and compared with literature data. Occasional deviations are discussed. Images of some remarkable systems are also presented.

  7. Application of infrared camera to bituminous concrete pavements: measuring vehicle

    NASA Astrophysics Data System (ADS)

    Janků, Michal; Stryk, Josef

    2017-09-01

    Infrared thermography (IR) has been used for decades in certain fields. However, the technological level of advancement of measuring devices has not been sufficient for some applications. Over the recent years, good quality thermal cameras with high resolution and very high thermal sensitivity have started to appear on the market. The development in the field of measuring technologies allowed the use of infrared thermography in new fields and for larger number of users. This article describes the research in progress in Transport Research Centre with a focus on the use of infrared thermography for diagnostics of bituminous road pavements. A measuring vehicle, equipped with a thermal camera, digital camera and GPS sensor, was designed for the diagnostics of pavements. New, highly sensitive, thermal cameras allow to measure very small temperature differences from the moving vehicle. This study shows the potential of a high-speed inspection without lane closures while using IR thermography.

  8. Consistency between real and synthetic fast-ion measurements at ASDEX Upgrade

    NASA Astrophysics Data System (ADS)

    Rasmussen, J.; Nielsen, S. K.; Stejner, M.; Geiger, B.; Salewski, M.; Jacobsen, A. S.; Korsholm, S. B.; Leipold, F.; Michelsen, P. K.; Moseev, D.; Schubert, M.; Stober, J.; Tardini, G.; Wagner, D.; The ASDEX Upgrade Team

    2015-07-01

    Internally consistent characterization of the properties of the fast-ion distribution from multiple diagnostics is a prerequisite for obtaining a full understanding of fast-ion behavior in tokamak plasmas. Here we benchmark several absolutely-calibrated core fast-ion diagnostics at ASDEX Upgrade by comparing fast-ion measurements from collective Thomson scattering, fast-ion {{\\text{D}}α} spectroscopy, and neutron rate detectors with numerical predictions from the TRANSP/NUBEAM transport code. We also study the sensitivity of the theoretical predictions to uncertainties in the plasma kinetic profiles. We find that theory and measurements generally agree within these uncertainties for all three diagnostics during heating phases with either one or two neutral beam injection sources. This suggests that the measurements can be described by the same model assuming classical slowing down of fast ions. Since the three diagnostics in the adopted configurations probe partially overlapping regions in fast-ion velocity space, this is also consistent with good internal agreement among the measurements themselves. Hence, our results support the feasibility of combining multiple diagnostics at ASDEX Upgrade to reconstruct the fast-ion distribution function in 2D velocity space.

  9. Double Star Measurements at the Southern Sky with a 50 cm Reflector and a Fast CCD Camera in 2014

    NASA Astrophysics Data System (ADS)

    Anton, Rainer

    2015-04-01

    A Ritchey-Chrétien reflector with 50 cm aperture was used in Namibia for recordings of double stars with a fast CCD camera and a notebook computer. From superposition of "lucky images", measurements of 91 pairings in 79 double and multiple systems were obtained and compared with literature data. Occasional deviations are discussed. Some images of noteworthy systems are also presented.

  10. Investigating plasma viscosity with fast framing photography in the ZaP-HD Flow Z-Pinch experiment

    NASA Astrophysics Data System (ADS)

    Weed, Jonathan Robert

    The ZaP-HD Flow Z-Pinch experiment investigates the stabilizing effect of sheared axial flows while scaling toward a high-energy-density laboratory plasma (HEDLP > 100 GPa). Stabilizing flows may persist until viscous forces dissipate a sheared flow profile. Plasma viscosity is investigated by measuring scale lengths in turbulence intentionally introduced in the plasma flow. A boron nitride turbulence-tripping probe excites small scale length turbulence in the plasma, and fast framing optical cameras are used to study time-evolved turbulent structures and viscous dissipation. A Hadland Imacon 790 fast framing camera is modified for digital image capture, but features insufficient resolution to study turbulent structures. A Shimadzu HPV-X camera captures the evolution of turbulent structures with great spatial and temporal resolution, but is unable to resolve the anticipated Kolmogorov scale in ZaP-HD as predicted by a simplified pinch model.

  11. Fast PSP measurements of wall-pressure fluctuation in low-speed flows: improvements using proper orthogonal decomposition

    NASA Astrophysics Data System (ADS)

    Peng, Di; Wang, Shaofei; Liu, Yingzheng

    2016-04-01

    Fast pressure-sensitive paint (PSP) is very useful in flow diagnostics due to its fast response and high spatial resolution, but its applications in low-speed flows are usually challenging due to limitations of paint's pressure sensitivity and the capability of high-speed imagers. The poor signal-to-noise ratio in low-speed cases makes it very difficult to extract useful information from the PSP data. In this study, unsteady PSP measurements were made on a flat plate behind a cylinder in a low-speed wind tunnel (flow speed from 10 to 17 m/s). Pressure fluctuations (Δ P) on the plate caused by vortex-plate interaction were recorded continuously by fast PSP (using a high-speed camera) and a microphone array. Power spectrum of pressure fluctuations and phase-averaged Δ P obtained from PSP and microphone were compared, showing good agreement in general. Proper orthogonal decomposition (POD) was used to reduce noise in PSP data and extract the dominant pressure features. The PSP results reconstructed from selected POD modes were then compared to the pressure data obtained simultaneously with microphone sensors. Based on the comparison of both instantaneous Δ P and root-mean-square of Δ P, it was confirmed that POD analysis could effectively remove noise while preserving the instantaneous pressure information with good fidelity, especially for flows with strong periodicity. This technique extends the application range of fast PSP and can be a powerful tool for fundamental fluid mechanics research at low speed.

  12. Determining fast orientation changes of multi-spectral line cameras from the primary images

    NASA Astrophysics Data System (ADS)

    Wohlfeil, Jürgen

    2012-01-01

    Fast orientation changes of airborne and spaceborne line cameras cannot always be avoided. In such cases it is essential to measure them with high accuracy to ensure a good quality of the resulting imagery products. Several approaches exist to support the orientation measurement by using optical information received through the main objective/telescope. In this article an approach is proposed that allows the determination of non-systematic orientation changes between every captured line. It does not require any additional camera hardware or onboard processing capabilities but the payload images and a rough estimate of the camera's trajectory. The approach takes advantage of the typical geometry of multi-spectral line cameras with a set of linear sensor arrays for different spectral bands on the focal plane. First, homologous points are detected within the heavily distorted images of different spectral bands. With their help a connected network of geometrical correspondences can be built up. This network is used to calculate the orientation changes of the camera with the temporal and angular resolution of the camera. The approach was tested with an extensive set of aerial surveys covering a wide range of different conditions and achieved precise and reliable results.

  13. A real-time camera calibration system based on OpenCV

    NASA Astrophysics Data System (ADS)

    Zhang, Hui; Wang, Hua; Guo, Huinan; Ren, Long; Zhou, Zuofeng

    2015-07-01

    Camera calibration is one of the essential steps in the computer vision research. This paper describes a real-time OpenCV based camera calibration system, and developed and implemented in the VS2008 environment. Experimental results prove that the system to achieve a simple and fast camera calibration, compared with MATLAB, higher precision and does not need manual intervention, and can be widely used in various computer vision system.

  14. Cost-effective handling of digital medical images in the telemedicine environment.

    PubMed

    Choong, Miew Keen; Logeswaran, Rajasvaran; Bister, Michel

    2007-09-01

    This paper concentrates on strategies for less costly handling of medical images. Aspects of digitization using conventional digital cameras, lossy compression with good diagnostic quality, and visualization through less costly monitors are discussed. For digitization of film-based media, subjective evaluation of the suitability of digital cameras as an alternative to the digitizer was undertaken. To save on storage, bandwidth and transmission time, the acceptable degree of compression with diagnostically no loss of important data was studied through randomized double-blind tests of the subjective image quality when compression noise was kept lower than the inherent noise. A diagnostic experiment was undertaken to evaluate normal low cost computer monitors as viable viewing displays for clinicians. The results show that conventional digital camera images of X-ray images were diagnostically similar to the expensive digitizer. Lossy compression, when used moderately with the imaging noise to compression noise ratio (ICR) greater than four, can bring about image improvement with better diagnostic quality than the original image. Statistical analysis shows that there is no diagnostic difference between expensive high quality monitors and conventional computer monitors. The results presented show good potential in implementing the proposed strategies to promote widespread cost-effective telemedicine and digital medical environments. 2006 Elsevier Ireland Ltd

  15. Comparison of Sheath Power Transmission Factor for Neutral Beam Injection and Electron Cyclotron Heated Discharges in DIII-D

    NASA Astrophysics Data System (ADS)

    Donovan, D. C.; Buchenauer, D. A.; Watkins, J. G.; Leonard, A. W.; Lasnier, C. J.; Stangeby, P. C.

    2011-10-01

    The sheath power transmission factor (SPTF) is examined in DIII-D with a new IR camera, a more thermally robust Langmuir probe array, fast thermocouples, and a unique probe configuration on the Divertor Materials Evaluation System (DiMES). Past data collected from the fixed Langmuir Probes and Infrared Camera on DIII-D have indicated a SPTF near 1 at the strike point. Theory indicates that the SPTF should be approximately 7 and cannot be less than 5. SPTF values are calculated using independent measurements from the IR camera and fast thermocouples. Experiments have been performed with varying levels of electron cyclotron heating and neutral beam power. The ECH power does not involve fast ions, so the SPTF can be calculated and compared to previous experiments to determine the extent to which fast ions may be influencing the SPTF measurements, and potentially offer insight into the disagreement with the theory. Work supported in part by US DOE under DE-AC04-94AL85000, DE-FC02-04ER54698, and DE-AC52-07NA27344.

  16. 2D Measurements of the Balmer Series in Proto-MPEX using a Fast Visible Camera Setup

    NASA Astrophysics Data System (ADS)

    Lindquist, Elizabeth G.; Biewer, Theodore M.; Ray, Holly B.

    2017-10-01

    The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device with densities up to 1020 m-3 and temperatures up to 20 eV. Broadband spectral measurements show the visible emission spectra are solely due to the Balmer lines of deuterium. Monochromatic and RGB color Sanstreak SC1 Edgertronic fast visible cameras capture high speed video of plasmas in Proto-MPEX. The color camera is equipped with a long pass 450 nm filter and an internal Bayer filter to view the Dα line at 656 nm on the red channel and the Dβ line at 486 nm on the blue channel. The monochromatic camera has a 434 nm narrow bandpass filter to view the Dγ intensity. In the setup, a 50/50 beam splitter is used so both cameras image the same region of the plasma discharge. Camera images were aligned to each other by viewing a grid ensuring 1 pixel registration between the two cameras. A uniform intensity calibrated white light source was used to perform a pixel-to-pixel relative and an absolute intensity calibration for both cameras. Python scripts that combined the dual camera data, rendering the Dα, Dβ, and Dγ intensity ratios. Observations from Proto-MPEX discharges will be presented. This work was supported by the US. D.O.E. contract DE-AC05-00OR22725.

  17. FAST CHOPPER BUILDING, TRA665. CAMERA FACING NORTH. NOTE BRICKEDIN WINDOW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FAST CHOPPER BUILDING, TRA-665. CAMERA FACING NORTH. NOTE BRICKED-IN WINDOW ON RIGHT SIDE (BELOW PAINTED NUMERALS "665"). SLIDING METAL DOOR ON COVERED RAIL AT UPPER LEVEL. SHELTERED ENTRANCE TO STEEL SHIELDING DOOR. DOOR INTO MTR SERVICE BUILDING, TRA-635, STANDS OPEN. MTR BEHIND CHOPPER BUILDING. INL NEGATIVE NO. HD42-1. Mike Crane, Photographer, 3/2004 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  18. Soft x-ray streak camera for laser fusion applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stradling, G.L.

    This thesis reviews the development and significance of the soft x-ray streak camera (SXRSC) in the context of inertial confinement fusion energy development. A brief introduction of laser fusion and laser fusion diagnostics is presented. The need for a soft x-ray streak camera as a laser fusion diagnostic is shown. Basic x-ray streak camera characteristics, design, and operation are reviewed. The SXRSC design criteria, the requirement for a subkilovolt x-ray transmitting window, and the resulting camera design are explained. Theory and design of reflector-filter pair combinations for three subkilovolt channels centered at 220 eV, 460 eV, and 620 eV aremore » also presented. Calibration experiments are explained and data showing a dynamic range of 1000 and a sweep speed of 134 psec/mm are presented. Sensitivity modifications to the soft x-ray streak camera for a high-power target shot are described. A preliminary investigation, using a stepped cathode, of the thickness dependence of the gold photocathode response is discussed. Data from a typical Argus laser gold-disk target experiment are shown.« less

  19. C-RED One and C-RED2: SWIR high-performance cameras using Saphira e-APD and Snake InGaAs detectors

    NASA Astrophysics Data System (ADS)

    Gach, Jean-Luc; Feautrier, Philippe; Stadler, Eric; Clop, Fabien; Lemarchand, Stephane; Carmignani, Thomas; Wanwanscappel, Yann; Boutolleau, David

    2018-02-01

    After the development of the OCAM2 EMCCD fast visible camera dedicated to advanced adaptive optics wavefront sensing, First Light Imaging moved to the SWIR fast cameras with the development of the C-RED One and the C-RED 2 cameras. First Light Imaging's C-RED One infrared camera is capable of capturing up to 3500 full frames per second with a subelectron readout noise and very low background. C-RED One is based on the last version of the SAPHIRA detector developed by Leonardo UK. This breakthrough has been made possible thanks to the use of an e-APD infrared focal plane array which is a real disruptive technology in imagery. C-RED One is an autonomous system with an integrated cooling system and a vacuum regeneration system. It operates its sensor with a wide variety of read out techniques and processes video on-board thanks to an FPGA. We will show its performances and expose its main features. In addition to this project, First Light Imaging developed an InGaAs 640x512 fast camera with unprecedented performances in terms of noise, dark and readout speed based on the SNAKE SWIR detector from Sofradir. The camera was called C-RED 2. The C-RED 2 characteristics and performances will be described. The C-RED One project has received funding from the European Union's Horizon 2020 research and innovation program under grant agreement N° 673944. The C-RED 2 development is supported by the "Investments for the future" program and the Provence Alpes Côte d'Azur Region, in the frame of the CPER.

  20. A fast processing route of aspheric polydimethylsiloxane lenses array (APLA) and optical characterization for smartphone microscopy

    NASA Astrophysics Data System (ADS)

    Fuh, Yiin-Kuen; Lai, Zheng-Hong

    2017-02-01

    A fast processing route of aspheric polydimethylsiloxane (PDMS) lenses array (APLA) is proposed via the combined effect of inverted gravitational and heat-assisted forces. The fabrication time can be dramatically reduced to 30 s, compared favorably to the traditional duration of 2 hours of repeated cycles of addition-curing processes. In this paper, a low-cost flexible lens can be fabricated by repeatedly depositing, inverting, curing a hanging transparent PDMS elastomer droplet on a previously deposited curved structure. Complex structures with aspheric curve features and various focal lengths can be successfully produced and the fabricated 4 types of APLA have various focal lengths in the range of 7.03 mm, 6.00 mm, 5.33 mm, and 4.43 mm, respectively. Empirically, a direct relationship between the PDMS volume and focal lengths of the lenses can be experimentally deducted. Using these fabricated APLA, an ordinary commercial smartphone camera can be easily transformed to a low-cost, portable digital microscopy (50×magnification) such that point of care diagnostic can be implemented pervasively.

  1. Configuring and Characterizing X-Rays for Laser-Driven Compression Experiments at the Dynamic Compression Sector

    NASA Astrophysics Data System (ADS)

    Li, Y.; Capatina, D.; D'Amico, K.; Eng, P.; Hawreliak, J.; Graber, T.; Rickerson, D.; Klug, J.; Rigg, P. A.; Gupta, Y. M.

    2017-06-01

    Coupling laser-driven compression experiments to the x-ray beam at the Dynamic Compression Sector (DCS) at the Advanced Photon Source (APS) of Argonne National Laboratory requires state-of-the-art x-ray focusing, pulse isolation, and diagnostics capabilities. The 100J UV pulsed laser system can be fired once every 20 minutes so precise alignment and focusing of the x-rays on each new sample must be fast and reproducible. Multiple Kirkpatrick-Baez (KB) mirrors are used to achieve a focal spot size as small as 50 μm at the target, while the strategic placement of scintillating screens, cameras, and detectors allows for fast diagnosis of the beam shape, intensity, and alignment of the sample to the x-ray beam. In addition, a series of x-ray choppers and shutters are used to ensure that the sample is exposed to only a single x-ray pulse ( 80ps) during the dynamic compression event and require highly precise synchronization. Details of the technical requirements, layout, and performance of these instruments will be presented. Work supported by DOE/NNSA.

  2. Development of Diagnostics for the Livermore DPF Devices

    NASA Astrophysics Data System (ADS)

    Mitrani, James; Prasad, Rahul R.; Podpaly, Yuri A.; Cooper, Christopher M.; Chapman, Steven F.; Shaw, Brian H.; Povilus, Alexander P.; Schmidt, Andrea

    2017-10-01

    LLNL is commissioning several new diagnostics to understand and optimize ion and neutron production in their dense plasma focus (DPF) systems. Gas fills used in DPF devices at LLNL are Deuterium (D2) and He accelerated onto a Be target, for production of neutrons. Neutron yields are currently measured with Helium-3 tubes, and development of yttrium-based activation detectors is currently underway. Neutron time-of-flight (nTOF) signals from prompt neutrons will be measured with gadolinium-doped liquid scintillators. An ion energy analyzer will be used to diagnose energy distribution of D + and He +2 ions. Additionally, a fast frame ICCD camera has been applied to image the plasma sheath during the rundown and pinch phases. Sheath velocity will be measured with an array of discrete photodiodes with ns time responses. A discussion of our results will be presented. Prepared by LLNL under Contract DE-AC52-07NA27344, and supported by the Laboratory Directed Research and Development Program (15-ERD-034) at LLNL and the Office of Defense Nuclear Nonproliferation Research and Development within U.S. Department of Energy.

  3. Flame analysis using image processing techniques

    NASA Astrophysics Data System (ADS)

    Her Jie, Albert Chang; Zamli, Ahmad Faizal Ahmad; Zulazlan Shah Zulkifli, Ahmad; Yee, Joanne Lim Mun; Lim, Mooktzeng

    2018-04-01

    This paper presents image processing techniques with the use of fuzzy logic and neural network approach to perform flame analysis. Flame diagnostic is important in the industry to extract relevant information from flame images. Experiment test is carried out in a model industrial burner with different flow rates. Flame features such as luminous and spectral parameters are extracted using image processing and Fast Fourier Transform (FFT). Flame images are acquired using FLIR infrared camera. Non-linearities such as thermal acoustic oscillations and background noise affect the stability of flame. Flame velocity is one of the important characteristics that determines stability of flame. In this paper, an image processing method is proposed to determine flame velocity. Power spectral density (PSD) graph is a good tool for vibration analysis where flame stability can be approximated. However, a more intelligent diagnostic system is needed to automatically determine flame stability. In this paper, flame features of different flow rates are compared and analyzed. The selected flame features are used as inputs to the proposed fuzzy inference system to determine flame stability. Neural network is used to test the performance of the fuzzy inference system.

  4. Single-shot lifetime-based PSP and TSP measurements on turbocharger compressor blades

    NASA Astrophysics Data System (ADS)

    Peng, Di; Jiao, Lingrui; Yu, Yuelong; Liu, Yingzheng; Oshio, Tetsuya; Kawakubo, Tomoki; Yakushiji, Akimitsu

    2017-09-01

    Fast-responding pressure-sensitive paint (Fast PSP) and temperature-sensitive paint (TSP) measurements were conducted on two turbocharger compressors using a single-shot lifetime-based technique. The fast PSP and TSP were applied on separate blades of one compressor, and both paints were excited by a pulsed 532 nm Nd:YAG laser. The luminescent decay signals following the laser pulse were recorded by a CCD camera in a double-exposure mode. Instantaneous pressure and temperature fields on compressor blades were obtained simultaneously, for rotation speeds up to 150,000 rpm. The variations in pressure and temperature fields with rotation speed, flow rate and runtime were clearly visualized, showing the advantage of high spatial resolution. Severe image blurring problems and significant temperature-induced errors in the PSP results were found at high rotation speeds. The first issue was addressed by incorporating a deconvolution-based deblurring algorithm to recover the clear image from the blurred image using the combination of luminescent lifetime and rotation speed. The second issue was resolved by applying a pixel-by-pixel temperature correction based on the TSP results. The current technique has shown great capabilities in flow diagnostics of turbomachinery and can serve as a powerful tool for CFD validations and design optimizations.

  5. Real-time plasma control based on the ISTTOK tomography diagnostica)

    NASA Astrophysics Data System (ADS)

    Carvalho, P. J.; Carvalho, B. B.; Neto, A.; Coelho, R.; Fernandes, H.; Sousa, J.; Varandas, C.; Chávez-Alarcón, E.; Herrera-Velázquez, J. J. E.

    2008-10-01

    The presently available processing power in generic processing units (GPUs) combined with state-of-the-art programmable logic devices benefits the implementation of complex, real-time driven, data processing algorithms for plasma diagnostics. A tomographic reconstruction diagnostic has been developed for the ISTTOK tokamak, based on three linear pinhole cameras each with ten lines of sight. The plasma emissivity in a poloidal cross section is computed locally on a submillisecond time scale, using a Fourier-Bessel algorithm, allowing the use of the output signals for active plasma position control. The data acquisition and reconstruction (DAR) system is based on ATCA technology and consists of one acquisition board with integrated field programmable gate array (FPGA) capabilities and a dual-core Pentium module running real-time application interface (RTAI) Linux. In this paper, the DAR real-time firmware/software implementation is presented, based on (i) front-end digital processing in the FPGA; (ii) a device driver specially developed for the board which enables streaming data acquisition to the host GPU; and (iii) a fast reconstruction algorithm running in Linux RTAI. This system behaves as a module of the central ISTTOK control and data acquisition system (FIRESIGNAL). Preliminary results of the above experimental setup are presented and a performance benchmarking against the magnetic coil diagnostic is shown.

  6. The software architecture of the camera for the ASTRI SST-2M prototype for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Sangiorgi, Pierluca; Capalbi, Milvia; Gimenes, Renato; La Rosa, Giovanni; Russo, Francesco; Segreto, Alberto; Sottile, Giuseppe; Catalano, Osvaldo

    2016-07-01

    The purpose of this contribution is to present the current status of the software architecture of the ASTRI SST-2M Cherenkov Camera. The ASTRI SST-2M telescope is an end-to-end prototype for the Small Size Telescope of the Cherenkov Telescope Array. The ASTRI camera is an innovative instrument based on SiPM detectors and has several internal hardware components. In this contribution we will give a brief description of the hardware components of the camera of the ASTRI SST-2M prototype and of their interconnections. Then we will present the outcome of the software architectural design process that we carried out in order to identify the main structural components of the camera software system and the relationships among them. We will analyze the architectural model that describes how the camera software is organized as a set of communicating blocks. Finally, we will show where these blocks are deployed in the hardware components and how they interact. We will describe in some detail, the physical communication ports and external ancillary devices management, the high precision time-tag management, the fast data collection and the fast data exchange between different camera subsystems, and the interfacing with the external systems.

  7. Digital fundus image grading with the non-mydriatic Visucam(PRO NM) versus the FF450(plus) camera in diabetic retinopathy.

    PubMed

    Neubauer, Aljoscha S; Rothschuh, Antje; Ulbig, Michael W; Blum, Marcus

    2008-03-01

    Grading diabetic retinopathy in clinical trials is frequently based on 7-field stereo photography of the fundus in diagnostic mydriasis. In terms of image quality, the FF450(plus) camera (Carl Zeiss Meditec AG, Jena, Germany) defines a high-quality reference. The aim of the study was to investigate if the fully digital fundus camera Visucam(PRO NM) could serve as an alternative in clinical trials requiring 7-field stereo photography. A total of 128 eyes of diabetes patients were enrolled in the randomized, controlled, prospective trial. Seven-field stereo photography was performed with the Visucam(PRO NM) and the FF450(plus) camera, in random order, both in diagnostic mydriasis. The resulting 256 image sets from the two camera systems were graded for retinopathy levels and image quality (on a scale of 1-5); both were anonymized and blinded to the image source. On FF450(plus) stereoscopic imaging, 20% of the patients had no or mild diabetic retinopathy (ETDRS level < or = 20) and 29% had no macular oedema. No patient had to be excluded as a result of image quality. Retinopathy level did not influence the quality of grading or of images. Excellent overall correspondence was obtained between the two fundus cameras regarding retinopathy levels (kappa 0.87) and macular oedema (kappa 0.80). In diagnostic mydriasis the image quality of the Visucam was graded slightly as better than that of the FF450(plus) (2.20 versus 2.41; p < 0.001), especially for pupils < 7 mm in mydriasis. The non-mydriatic Visucam(PRO NM) offers good image quality and is suitable as a more cost-efficient and easy-to-operate camera for applications and clinical trials requiring 7-field stereo photography.

  8. A single camera photogrammetry system for multi-angle fast localization of EEG electrodes.

    PubMed

    Qian, Shuo; Sheng, Yang

    2011-11-01

    Photogrammetry has become an effective method for the determination of electroencephalography (EEG) electrode positions in three dimensions (3D). Capturing multi-angle images of the electrodes on the head is a fundamental objective in the design of photogrammetry system for EEG localization. Methods in previous studies are all based on the use of either a rotating camera or multiple cameras, which are time-consuming or not cost-effective. This study aims to present a novel photogrammetry system that can realize simultaneous acquisition of multi-angle head images in a single camera position. Aligning two planar mirrors with the angle of 51.4°, seven views of the head with 25 electrodes are captured simultaneously by the digital camera placed in front of them. A complete set of algorithms for electrode recognition, matching, and 3D reconstruction is developed. It is found that the elapsed time of the whole localization procedure is about 3 min, and camera calibration computation takes about 1 min, after the measurement of calibration points. The positioning accuracy with the maximum error of 1.19 mm is acceptable. Experimental results demonstrate that the proposed system provides a fast and cost-effective method for the EEG positioning.

  9. A state observer for using a slow camera as a sensor for fast control applications

    NASA Astrophysics Data System (ADS)

    Gahleitner, Reinhard; Schagerl, Martin

    2013-03-01

    This contribution concerns about a problem that often arises in vision based control, when a camera is used as a sensor for fast control applications, or more precisely, when the sample rate of the control loop is higher than the frame rate of the camera. In control applications for mechanical axes, e.g. in robotics or automated production, a camera and some image processing can be used as a sensor to detect positions or angles. The sample time in these applications is typically in the range of a few milliseconds or less and this demands the use of a camera with a high frame rate up to 1000 fps. The presented solution is a special state observer that can work with a slower and therefore cheaper camera to estimate the state variables at the higher sample rate of the control loop. To simplify the image processing for the determination of positions or angles and make it more robust, some LED markers are applied to the plant. Simulation and experimental results show that the concept can be used even if the plant is unstable like the inverted pendulum.

  10. Mary, a Pipeline to Aid Discovery of Optical Transients

    NASA Astrophysics Data System (ADS)

    Andreoni, I.; Jacobs, C.; Hegarty, S.; Pritchard, T.; Cooke, J.; Ryder, S.

    2017-09-01

    The ability to quickly detect transient sources in optical images and trigger multi-wavelength follow up is key for the discovery of fast transients. These include events rare and difficult to detect such as kilonovae, supernova shock breakout, and `orphan' Gamma-ray Burst afterglows. We present the Mary pipeline, a (mostly) automated tool to discover transients during high-cadenced observations with the Dark Energy Camera at Cerro Tololo Inter-American Observatory (CTIO). The observations are part of the `Deeper Wider Faster' programme, a multi-facility, multi-wavelength programme designed to discover fast transients, including counterparts to Fast Radio Bursts and gravitational waves. Our tests of the Mary pipeline on Dark Energy Camera images return a false positive rate of 2.2% and a missed fraction of 3.4% obtained in less than 2 min, which proves the pipeline to be suitable for rapid and high-quality transient searches. The pipeline can be adapted to search for transients in data obtained with imagers other than Dark Energy Camera.

  11. Action-angle formulation of generalized, orbit-based, fast-ion diagnostic weight functions

    NASA Astrophysics Data System (ADS)

    Stagner, L.; Heidbrink, W. W.

    2017-09-01

    Due to the usually complicated and anisotropic nature of the fast-ion distribution function, diagnostic velocity-space weight functions, which indicate the sensitivity of a diagnostic to different fast-ion velocities, are used to facilitate the analysis of experimental data. Additionally, when velocity-space weight functions are discretized, a linear equation relating the fast-ion density and the expected diagnostic signal is formed. In a technique known as velocity-space tomography, many measurements can be combined to create an ill-conditioned system of linear equations that can be solved using various computational methods. However, when velocity-space weight functions (which by definition ignore spatial dependencies) are used, velocity-space tomography is restricted, both by the accuracy of its forward model and also by the availability of spatially overlapping diagnostic measurements. In this work, we extend velocity-space weight functions to a full 6D generalized coordinate system and then show how to reduce them to a 3D orbit-space without loss of generality using an action-angle formulation. Furthermore, we show how diagnostic orbit-weight functions can be used to infer the full fast-ion distribution function, i.e., orbit tomography. In depth derivations of orbit weight functions for the neutron, neutral particle analyzer, and fast-ion D-α diagnostics are also shown.

  12. SU-E-J-17: A Study of Accelerator-Induced Cerenkov Radiation as a Beam Diagnostic and Dosimetry Tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bateman, F; Tosh, R

    2014-06-01

    Purpose: To investigate accelerator-induced Cerenkov radiation imaging as a possible beam diagnostic and medical dosimetry tool. Methods: Cerenkov emission produced by clinical accelerator beams in a water phantom was imaged using a camera system comprised of a high-sensitivity thermoelectrically-cooled CCD camera coupled to a large aperture (f/0.75) objective lens with 16:1 magnification. This large format lens allows a significant amount of the available Cerenkov light to be collected and focused onto the CCD camera to form the image. Preliminary images, obtained with 6 MV photon beams, used an unshielded camera mounted horizontally with the beam normal to the water surface,more » and confirmed the detection of Cerenkov radiation. Several improvements were subsequently made including the addition of radiation shielding around the camera, and altering of the beam and camera angles to give a more favorable geometry for Cerenkov light collection. A detailed study was then undertaken over a range of electron and photon beam energies and dose rates to investigate the possibility of using this technique for beam diagnostics and dosimetry. Results: A series of images were obtained at a fixed dose rate over a range of electron energies from 6 to 20 MeV. The location of maximum intensity was found to vary linearly with the energy of the beam. A linear relationship was also found between the light observed from a fixed point on the central axis and the dose rate for both photon and electron beams. Conclusion: We have found that the analysis of images of beam-induced Cerenkov light in a water phantom has potential for use as a beam diagnostic and medical dosimetry tool. Our future goals include the calibration of the light output in terms of radiation dose and development of a tomographic system for 3D Cerenkov imaging in water phantoms and other media.« less

  13. Heavy Ion Fusion Science Virtual National Laboratory 4th Quarter 2009 Milestone Report: Measure and simulate target temperature and dynamic response in optimized NDCX-I configurations with initial diagnostics suite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bieniosek, F.M.; Barnard, J.J.; Henestroza, E.

    2009-09-30

    This milestone has been met. The effort contains two main components: (1) Experimental results of warm dense matter target experiments on optimized NDCX-I configurations that include measurements of target temperature and transient target behavior. (2) A theoretical model of the target response to beam heating that includes an equilibrium heating model of the target foil and a model for droplet formation in the target for comparison with experimental results. The experiments on ion-beam target heating use a 300-350-keV K{sup +} pulsed beam from the Neutralized Compression Drift Experiment (NDCX-I) accelerator at LBNL. The NDCX-I accelerator delivers an uncompressed pulse beammore » of several microseconds with a typical power density of >100 kW/cm{sup 2} over a final focus spot size of about 1 mm. An induction bunching module the NDCX-I compresses a portion of the beam pulse to reach a much higher power density over 2 nanoseconds. Under these conditions the free-standing foil targets are rapidly heated to temperatures to over 4000 K. We model the target thermal dynamics using the equation of heat conduction for the temperature T(x,t) as a function of time (t) and spatial dimension along the beam direction (x). The competing cooling processes release energy from the surface of the foil due to evaporation, radiation, and thermionic (Richardson) emission. A description of the experimental configuration of the target chamber and results from initial beam-target experiments are reported in our FY08 4th Quarter and FY09 2nd Quarter Milestone Reports. The WDM target diagnostics include a high-speed multichannel optical pyrometer, optical streak camera, VISAR, and high-speed gated cameras. The fast optical pyrometer is a unique and significant new diagnostic which provides valuable information on the temperature evolution of the heated target.« less

  14. Dual multispectral and 3D structured light laparoscope

    NASA Astrophysics Data System (ADS)

    Clancy, Neil T.; Lin, Jianyu; Arya, Shobhit; Hanna, George B.; Elson, Daniel S.

    2015-03-01

    Intraoperative feedback on tissue function, such as blood volume and oxygenation would be useful to the surgeon in cases where current clinical practice relies on subjective measures, such as identification of ischaemic bowel or tissue viability during anastomosis formation. Also, tissue surface profiling may be used to detect and identify certain pathologies, as well as diagnosing aspects of tissue health such as gut motility. In this paper a dual modality laparoscopic system is presented that combines multispectral reflectance and 3D surface imaging. White light illumination from a xenon source is detected by a laparoscope-mounted fast filter wheel camera to assemble a multispectral image (MSI) cube. Surface shape is then calculated using a spectrally-encoded structured light (SL) pattern detected by the same camera and triangulated using an active stereo technique. Images of porcine small bowel were acquired during open surgery. Tissue reflectance spectra were acquired and blood volume was calculated at each spatial pixel across the bowel wall and mesentery. SL features were segmented and identified using a `normalised cut' algoritm and the colour vector of each spot. Using the 3D geometry defined by the camera coordinate system the multispectral data could be overlaid onto the surface mesh. Dual MSI and SL imaging has the potential to provide augmented views to the surgeon supplying diagnostic information related to blood supply health and organ function. Future work on this system will include filter optimisation to reduce noise in tissue optical property measurement, and minimise spot identification errors in the SL pattern.

  15. Exploding Balloons, Deformed Balls, Strange Reflections and Breaking Rods: Slow Motion Analysis of Selected Hands-On Experiments

    ERIC Educational Resources Information Center

    Vollmer, Michael; Mollmann, Klaus-Peter

    2011-01-01

    A selection of hands-on experiments from different fields of physics, which happen too fast for the eye or video cameras to properly observe and analyse the phenomena, is presented. They are recorded and analysed using modern high speed cameras. Two types of cameras were used: the first were rather inexpensive consumer products such as Casio…

  16. A tangentially viewing fast ion D-alpha diagnostic for NSTX.

    PubMed

    Bortolon, A; Heidbrink, W W; Podestà, M

    2010-10-01

    A second fast ion D-alpha (FIDA) installation is planned at NSTX to complement the present perpendicular viewing FIDA diagnostics. Following the present diagnostic scheme, the new diagnostic will consist of two instruments: a spectroscopic diagnostic that measures fast ion spectra and profiles at 16 radial points with 5-10 ms resolution and a system that uses a band pass filter and photomultiplier to measure changes in FIDA light with 50 kHz sampling rate. The new pair of FIDA instruments will view the heating beams tangentially. The viewing geometry minimizes spectral contamination by beam emission or edge sources of background emission. The improved velocity-space resolution will provide detailed information about neutral-beam current drive and about fast ion acceleration and transport by injected radio frequency waves and plasma instabilities.

  17. Time Resolved Detectors and Measurements for Accelerators and Beamlines at the Australian Synchrotron

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boland, M. J.; School of Physics, University of Melbourne, Parkville, Victoria 3010; Rassool, R. P.

    2010-06-23

    Time resolved experiments require precision timing equipment and careful configuration of the machine and the beamline. The Australian Synchrotron has a state of the art timing system that allows flexible, real-time control of the machine and beamline timing parameters to target specific electron bunches. Results from a proof-of-principle measurement with a pulsed laser and a streak camera on the optical diagnostic beamline will be presented. The timing system was also used to fast trigger the PILATUS detector on an x-ray beamline to measure the fill pattern dependent effects of the detector. PILATUS was able to coarsely measure the fill patternmore » in the storage ring which implies that fill pattern intensity variations need to be corrected for when using the detector in this mode.« less

  18. SHOK—The First Russian Wide-Field Optical Camera in Space

    NASA Astrophysics Data System (ADS)

    Lipunov, V. M.; Gorbovskoy, E. S.; Kornilov, V. G.; Panasyuk, M. I.; Amelushkin, A. M.; Petrov, V. L.; Yashin, I. V.; Svertilov, S. I.; Vedenkin, N. N.

    2018-02-01

    Onboard the spacecraft Lomonosov is established two fast, fixed, very wide-field cameras SHOK. The main goal of this experiment is the observation of GRB optical emission before, synchronously, and after the gamma-ray emission. The field of view of each of the cameras is placed in the gamma-ray burst detection area of other devices located onboard the "Lomonosov" spacecraft. SHOK provides measurements of optical emissions with a magnitude limit of ˜ 9-10m on a single frame with an exposure of 0.2 seconds. The device is designed for continuous sky monitoring at optical wavelengths in the very wide field of view (1000 square degrees each camera), detection and localization of fast time-varying (transient) optical sources on the celestial sphere, including provisional and synchronous time recording of optical emissions from the gamma-ray burst error boxes, detected by the BDRG device and implemented by a control signal (alert trigger) from the BDRG. The Lomonosov spacecraft has two identical devices, SHOK1 and SHOK2. The core of each SHOK device is a fast-speed 11-Megapixel CCD. Each of the SHOK devices represents a monoblock, consisting of a node observations of optical emission, the electronics node, elements of the mechanical construction, and the body.

  19. A fast algorithm for computer aided collimation gamma camera (CACAO)

    NASA Astrophysics Data System (ADS)

    Jeanguillaume, C.; Begot, S.; Quartuccio, M.; Douiri, A.; Franck, D.; Pihet, P.; Ballongue, P.

    2000-08-01

    The computer aided collimation gamma camera is aimed at breaking down the resolution sensitivity trade-off of the conventional parallel hole collimator. It uses larger and longer holes, having an added linear movement at the acquisition sequence. A dedicated algorithm including shift and sum, deconvolution, parabolic filtering and rotation is described. Examples of reconstruction are given. This work shows that a simple and fast algorithm, based on a diagonal dominant approximation of the problem can be derived. Its gives a practical solution to the CACAO reconstruction problem.

  20. Low-cost mobile phone microscopy with a reversed mobile phone camera lens.

    PubMed

    Switz, Neil A; D'Ambrosio, Michael V; Fletcher, Daniel A

    2014-01-01

    The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples.

  1. Low-Cost Mobile Phone Microscopy with a Reversed Mobile Phone Camera Lens

    PubMed Central

    Fletcher, Daniel A.

    2014-01-01

    The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples. PMID:24854188

  2. Combined use of a priori data for fast system self-calibration of a non-rigid multi-camera fringe projection system

    NASA Astrophysics Data System (ADS)

    Stavroulakis, Petros I.; Chen, Shuxiao; Sims-Waterhouse, Danny; Piano, Samanta; Southon, Nicholas; Bointon, Patrick; Leach, Richard

    2017-06-01

    In non-rigid fringe projection 3D measurement systems, where either the camera or projector setup can change significantly between measurements or the object needs to be tracked, self-calibration has to be carried out frequently to keep the measurements accurate1. In fringe projection systems, it is common to use methods developed initially for photogrammetry for the calibration of the camera(s) in the system in terms of extrinsic and intrinsic parameters. To calibrate the projector(s) an extra correspondence between a pre-calibrated camera and an image created by the projector is performed. These recalibration steps are usually time consuming and involve the measurement of calibrated patterns on planes, before the actual object can continue to be measured after a motion of a camera or projector has been introduced in the setup and hence do not facilitate fast 3D measurement of objects when frequent experimental setup changes are necessary. By employing and combining a priori information via inverse rendering, on-board sensors, deep learning and leveraging a graphics processor unit (GPU), we assess a fine camera pose estimation method which is based on optimising the rendering of a model of a scene and the object to match the view from the camera. We find that the success of this calibration pipeline can be greatly improved by using adequate a priori information from the aforementioned sources.

  3. Fast calculation method of computer-generated hologram using a depth camera with point cloud gridding

    NASA Astrophysics Data System (ADS)

    Zhao, Yu; Shi, Chen-Xiao; Kwon, Ki-Chul; Piao, Yan-Ling; Piao, Mei-Lan; Kim, Nam

    2018-03-01

    We propose a fast calculation method for a computer-generated hologram (CGH) of real objects that uses a point cloud gridding method. The depth information of the scene is acquired using a depth camera and the point cloud model is reconstructed virtually. Because each point of the point cloud is distributed precisely to the exact coordinates of each layer, each point of the point cloud can be classified into grids according to its depth. A diffraction calculation is performed on the grids using a fast Fourier transform (FFT) to obtain a CGH. The computational complexity is reduced dramatically in comparison with conventional methods. The feasibility of the proposed method was confirmed by numerical and optical experiments.

  4. Fast simulation of yttrium-90 bremsstrahlung photons with GATE.

    PubMed

    Rault, Erwann; Staelens, Steven; Van Holen, Roel; De Beenhouwer, Jan; Vandenberghe, Stefaan

    2010-06-01

    Multiple investigators have recently reported the use of yttrium-90 (90Y) bremsstrahlung single photon emission computed tomography (SPECT) imaging for the dosimetry of targeted radionuclide therapies. Because Monte Carlo (MC) simulations are useful for studying SPECT imaging, this study investigates the MC simulation of 90Y bremsstrahlung photons in SPECT. To overcome the computationally expensive simulation of electrons, the authors propose a fast way to simulate the emission of 90Y bremsstrahlung photons based on prerecorded bremsstrahlung photon probability density functions (PDFs). The accuracy of bremsstrahlung photon simulation is evaluated in two steps. First, the validity of the fast bremsstrahlung photon generator is checked. To that end, fast and analog simulations of photons emitted from a 90Y point source in a water phantom are compared. The same setup is then used to verify the accuracy of the bremsstrahlung photon simulations, comparing the results obtained with PDFs generated from both simulated and measured data to measurements. In both cases, the energy spectra and point spread functions of the photons detected in a scintillation camera are used. Results show that the fast simulation method is responsible for a 5% overestimation of the low-energy fluence (below 75 keV) of the bremsstrahlung photons detected using a scintillation camera. The spatial distribution of the detected photons is, however, accurately reproduced with the fast method and a computational acceleration of approximately 17-fold is achieved. When measured PDFs are used in the simulations, the simulated energy spectrum of photons emitted from a point source of 90Y in a water phantom and detected in a scintillation camera closely approximates the measured spectrum. The PSF of the photons imaged in the 50-300 keV energy window is also accurately estimated with a 12.4% underestimation of the full width at half maximum and 4.5% underestimation of the full width at tenth maximum. Despite its limited accuracy, the fast bremsstrahlung photon generator is well suited for the simulation of bremsstrahlung photons emitted in large homogeneous organs, such as the liver, and detected in a scintillation camera. The computational acceleration makes it very useful for future investigations of 90Y bremsstrahlung SPECT imaging.

  5. Diagnostics for Z-pinch implosion experiments on PTS

    NASA Astrophysics Data System (ADS)

    Ren, X. D.; Huang, X. B.; Zhou, S. T.; Zhang, S. Q.; Dan, J. K.; Li, J.; Cai, H. C.; Wang, K. L.; Ouyang, K.; Xu, Q.; Duan, S. C.; Chen, G. H.; Wang, M.; Feng, S. P.; Yang, L. B.; Xie, W. P.; Deng, J. J.

    2014-12-01

    The preliminary experiments of wire array implosion were performed on PTS, a 10 MA z-pinch driver with a 70 ns rise time. A set of diagnostics have been developed and fielded on PTS to study pinch physics and implosion dynamics of wire array. Radiated power measurement for soft x-rays was performed by multichannel filtered x-ray diode array, and flat spectral responses x-ray diode detector. Total x-ray yield was measured by a calibrated, unfiltered nickel bolometer which was also used to obtain pinch power. Multiple time-gated pinhole cameras were used to produce spatial-resolved images of x-ray self-emission from plasmas. Two time-integrated pinhole cameras were used respectively with 20-μm Be filter and with multilayer mirrors to record images produced by >1-keV and 277±5 eV self-emission. An optical streak camera was used to produce radial implosion trajectories, and an x-ray streak camera paired with a horizontal slit was used to record a continuous time-history of emission with one-dimensional spatial resolution. A frequency-doubled Nd:YAG laser (532 nm) was used to produce four frame laser shadowgraph images with 6 ns time interval. We will briefly describe each of these diagnostics and present some typical results from them.

  6. The role of general practice in routes to diagnosis of lung cancer in Denmark: a population-based study of general practice involvement, diagnostic activity and diagnostic intervals.

    PubMed

    Guldbrandt, Louise Mahncke; Fenger-Grøn, Morten; Rasmussen, Torben Riis; Jensen, Henry; Vedsted, Peter

    2015-01-22

    Lung cancer stage at diagnosis predicts possible curative treatment. In Denmark and the UK, lung cancer patients have lower survival rates than citizens in most other European countries, which may partly be explained by a comparatively longer diagnostic interval in these two countries. In Denmark, a pathway was introduced in 2008 allowing general practitioners (GPs) to refer patients suspected of having lung cancer directly to fast-track diagnostics. However, symptom presentation of lung cancer in general practice is known to be diverse and complex, and systematic knowledge of the routes to diagnosis is needed to enable earlier lung cancer diagnosis in Denmark. This study aims to describe the routes to diagnosis, the diagnostic activity preceding diagnosis and the diagnostic intervals for lung cancer in the Danish setting. We conducted a national registry-based cohort study on 971 consecutive incident lung cancer patients in 2010 using data from national registries and GP questionnaires. GPs were involved in 68.3% of cancer patients' diagnostic pathways, and 27.4% of lung cancer patients were referred from the GP to fast-track diagnostic work-up. A minimum of one X-ray was performed in 85.6% of all cases before diagnosis. Patients referred through a fast-track route more often had diagnostic X-rays (66.0%) than patients who did not go through fast-track (49.4%). Overall, 33.6% of all patients had two or more X-rays performed during the 90 days before diagnosis. Patients whose symptoms were interpreted as non-alarm symptoms or who were not referred to fast-track were more likely to experience a long diagnostic interval than patients whose symptoms were interpreted as alarm symptoms or who were referred to fast-track. Lung cancer patients followed several diagnostic pathways. The existing fast-track pathway must be supplemented to ensure earlier detection of lung cancer. The high incidence of multiple X-rays warrants a continued effort to develop more accurate lung cancer tests for use in primary care.

  7. Single-photon sensitive fast ebCMOS camera system for multiple-target tracking of single fluorophores: application to nano-biophotonics

    NASA Astrophysics Data System (ADS)

    Cajgfinger, Thomas; Chabanat, Eric; Dominjon, Agnes; Doan, Quang T.; Guerin, Cyrille; Houles, Julien; Barbier, Remi

    2011-03-01

    Nano-biophotonics applications will benefit from new fluorescent microscopy methods based essentially on super-resolution techniques (beyond the diffraction limit) on large biological structures (membranes) with fast frame rate (1000 Hz). This trend tends to push the photon detectors to the single-photon counting regime and the camera acquisition system to real time dynamic multiple-target tracing. The LUSIPHER prototype presented in this paper aims to give a different approach than those of Electron Multiplied CCD (EMCCD) technology and try to answer to the stringent demands of the new nano-biophotonics imaging techniques. The electron bombarded CMOS (ebCMOS) device has the potential to respond to this challenge, thanks to the linear gain of the accelerating high voltage of the photo-cathode, to the possible ultra fast frame rate of CMOS sensors and to the single-photon sensitivity. We produced a camera system based on a 640 kPixels ebCMOS with its acquisition system. The proof of concept for single-photon based tracking for multiple single-emitters is the main result of this paper.

  8. Initial Demonstration of 9-MHz Framing Camera Rates on the FAST UV Drive Laser Pulse Trains

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lumpkin, A. H.; Edstrom Jr., D.; Ruan, J.

    2016-10-09

    We report the configuration of a Hamamatsu C5680 streak camera as a framing camera to record transverse spatial information of green-component laser micropulses at 3- and 9-MHz rates for the first time. The latter is near the time scale of the ~7.5-MHz revolution frequency of the Integrable Optics Test Accelerator (IOTA) ring and its expected synchroton radiation source temporal structure. The 2-D images are recorded with a Gig-E readout CCD camera. We also report a first proof of principle with an OTR source using the linac streak camera in a semi-framing mode.

  9. A simple algorithm for beam profile diagnostics using a thermographic camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katagiri, Ken; Hojo, Satoru; Honma, Toshihiro

    2014-03-15

    A new algorithm for digital image processing apparatuses is developed to evaluate profiles of high-intensity DC beams from temperature images of irradiated thin foils. Numerical analyses are performed to examine the reliability of the algorithm. To simulate the temperature images acquired by a thermographic camera, temperature distributions are numerically calculated for 20 MeV proton beams with different parameters. Noise in the temperature images which is added by the camera sensor is also simulated to account for its effect. Using the algorithm, beam profiles are evaluated from the simulated temperature images and compared with exact solutions. We find that niobium ismore » an appropriate material for the thin foil used in the diagnostic system. We also confirm that the algorithm is adaptable over a wide beam current range of 0.11–214 μA, even when employing a general-purpose thermographic camera with rather high noise (ΔT{sub NETD} ≃ 0.3 K; NETD: noise equivalent temperature difference)« less

  10. Thermographic measurements of high-speed metal cutting

    NASA Astrophysics Data System (ADS)

    Mueller, Bernhard; Renz, Ulrich

    2002-03-01

    Thermographic measurements of a high-speed cutting process have been performed with an infrared camera. To realize images without motion blur the integration times were reduced to a few microseconds. Since the high tool wear influences the measured temperatures a set-up has been realized which enables small cutting lengths. Only single images have been recorded because the process is too fast to acquire a sequence of images even with the frame rate of the very fast infrared camera which has been used. To expose the camera when the rotating tool is in the middle of the camera image an experimental set-up with a light barrier and a digital delay generator with a time resolution of 1 ns has been realized. This enables a very exact triggering of the camera at the desired position of the tool in the image. Since the cutting depth is between 0.1 and 0.2 mm a high spatial resolution was also necessary which was obtained by a special close-up lens allowing a resolution of app. 45 microns. The experimental set-up will be described and infrared images and evaluated temperatures of a titanium alloy and a carbon steel will be presented for cutting speeds up to 42 m/s.

  11. High-speed light field camera and frequency division multiplexing for fast multi-plane velocity measurements.

    PubMed

    Fischer, Andreas; Kupsch, Christian; Gürtler, Johannes; Czarske, Jürgen

    2015-09-21

    Non-intrusive fast 3d measurements of volumetric velocity fields are necessary for understanding complex flows. Using high-speed cameras and spectroscopic measurement principles, where the Doppler frequency of scattered light is evaluated within the illuminated plane, each pixel allows one measurement and, thus, planar measurements with high data rates are possible. While scanning is one standard technique to add the third dimension, the volumetric data is not acquired simultaneously. In order to overcome this drawback, a high-speed light field camera is proposed for obtaining volumetric data with each single frame. The high-speed light field camera approach is applied to a Doppler global velocimeter with sinusoidal laser frequency modulation. As a result, a frequency multiplexing technique is required in addition to the plenoptic refocusing for eliminating the crosstalk between the measurement planes. However, the plenoptic refocusing is still necessary in order to achieve a large refocusing range for a high numerical aperture that minimizes the measurement uncertainty. Finally, two spatially separated measurement planes with 25×25 pixels each are simultaneously acquired with a measurement rate of 0.5 kHz with a single high-speed camera.

  12. A near-Infrared SETI Experiment: Alignment and Astrometric precision

    NASA Astrophysics Data System (ADS)

    Duenas, Andres; Maire, Jerome; Wright, Shelley; Drake, Frank D.; Marcy, Geoffrey W.; Siemion, Andrew; Stone, Remington P. S.; Tallis, Melisa; Treffers, Richard R.; Werthimer, Dan

    2016-06-01

    Beginning in March 2015, a Near-InfraRed Optical SETI (NIROSETI) instrument aiming to search for fast nanosecond laser pulses, has been commissioned on the Nickel 1m-telescope at Lick Observatory. The NIROSETI instrument makes use of an optical guide camera, SONY ICX694 CCD from PointGrey, to align our selected sources into two 200µm near-infrared Avalanche Photo Diodes (APD) with a field-of-view of 2.5"x2.5" each. These APD detectors operate at very fast bandwidths and are able to detect pulse widths extending down into the nanosecond range. Aligning sources onto these relatively small detectors requires characterizing the guide camera plate scale, static optical distortion solution, and relative orientation with respect to the APD detectors. We determined the guide camera plate scale as 55.9+- 2.7 milli-arcseconds/pixel and magnitude limit of 18.15mag (+1.07/-0.58) in V-band. We will present the full distortion solution of the guide camera, orientation, and our alignment method between the camera and the two APDs, and will discuss target selection within the NIROSETI observational campaign, including coordination with Breakthrough Listen.

  13. A robust in-situ warp-correction algorithm for VISAR streak camera data at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Labaria, George R.; Warrick, Abbie L.; Celliers, Peter M.; Kalantar, Daniel H.

    2015-02-01

    The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory is a 192-beam pulsed laser system for high energy density physics experiments. Sophisticated diagnostics have been designed around key performance metrics to achieve ignition. The Velocity Interferometer System for Any Reflector (VISAR) is the primary diagnostic for measuring the timing of shocks induced into an ignition capsule. The VISAR system utilizes three streak cameras; these streak cameras are inherently nonlinear and require warp corrections to remove these nonlinear effects. A detailed calibration procedure has been developed with National Security Technologies (NSTec) and applied to the camera correction analysis in production. However, the camera nonlinearities drift over time affecting the performance of this method. An in-situ fiber array is used to inject a comb of pulses to generate a calibration correction in order to meet the timing accuracy requirements of VISAR. We develop a robust algorithm for the analysis of the comb calibration images to generate the warp correction that is then applied to the data images. Our algorithm utilizes the method of thin-plate splines (TPS) to model the complex nonlinear distortions in the streak camera data. In this paper, we focus on the theory and implementation of the TPS warp-correction algorithm for the use in a production environment.

  14. Night Vision and Electro-Optics Technology Transfer, 1972-1981

    DTIC Science & Technology

    1981-09-15

    Lixiscope offers potential applications as: a handheld instrument for dental radiography giving real-time ,1servation in orthodontic procedures; a portable...laboratory are described below. There are however, no hard and fast rules. The laboratory’s experimentation with different films, brackets , cameras and...good single lens reflex camera; an exvosure meter; a tripod; and a custom-built bracket to mate the camera and intensifier (Figure 2-1). Figure 2-1

  15. Characterization and optimization of the HyperV PLX- α coaxial-gun plasma jet

    NASA Astrophysics Data System (ADS)

    Case, Andrew; Brockington, Sam; Cruz, Edward; Witherspoon, F. Douglas

    2017-10-01

    We present results from characterizing and optimizing performance of the contoured gap coaxial plasma guns under development for the ARPA-E Accelerating Low-Cost Plasma Heating And Assembly (ALPHA) program. Plasma jet diagnostics include fast photodiodes for velocimetry and interferometry for line integrated density. Additionally we present results from spectroscopy, both time resolved high resolution spectroscopy using a novel detector and time integrated survey spectroscopy, for measurements of velocity and temperature as well as impurities. Fast imaging gives plume geometry and time integrated imaging gives overall light emission. Results from a novel long record length camera developed by HyperV will also be presented. Experimental results are compared to the desired target parameters for the plasma jets. The target values for the plasmoid are velocity of 50 km/s, mass of 3.5 mg, and length of 10 cm. The best results so far from the exploration of parameter space for gun operation are: 4 mg at >50 km/s, with a length of 10 cm. Peak axial density 34 cm downstream from the muzzle is 2 ×1016 cm-3. This work supported by the ARPA-E ALPHA Program under contract DE-AR0000566.

  16. DC drive system for cine/pulse cameras

    NASA Technical Reports Server (NTRS)

    Gerlach, R. H.; Sharpsteen, J. T.; Solheim, C. D.; Stoap, L. J.

    1977-01-01

    Camera-drive functions are separated mechanically into two groups which are driven by two separate dc brushless motors. First motor, a 90 deg stepper, drives rotating shutter; second electronically commutated motor drives claw and film transport. Shutter is made of one piece but has two openings for slow and fast exposures.

  17. Fast and robust curve skeletonization for real-world elongated objects

    USDA-ARS?s Scientific Manuscript database

    These datasets were generated for calibrating robot-camera systems. In an extension, we also considered the problem of calibrating robots with more than one camera. These datasets are provided as a companion to the paper, "Solving the Robot-World Hand-Eye(s) Calibration Problem with Iterative Meth...

  18. A drone detection with aircraft classification based on a camera array

    NASA Astrophysics Data System (ADS)

    Liu, Hao; Qu, Fangchao; Liu, Yingjian; Zhao, Wei; Chen, Yitong

    2018-03-01

    In recent years, because of the rapid popularity of drones, many people have begun to operate drones, bringing a range of security issues to sensitive areas such as airports and military locus. It is one of the important ways to solve these problems by realizing fine-grained classification and providing the fast and accurate detection of different models of drone. The main challenges of fine-grained classification are that: (1) there are various types of drones, and the models are more complex and diverse. (2) the recognition test is fast and accurate, in addition, the existing methods are not efficient. In this paper, we propose a fine-grained drone detection system based on the high resolution camera array. The system can quickly and accurately recognize the detection of fine grained drone based on hd camera.

  19. [Attachment to a fibergastroscope for cinematography].

    PubMed

    Ignat'ev, A I

    1979-01-01

    The diagnostic horizon of endoscopy is being extended due to the record of endoscopic pictures on the cinema film. The accessories offered by the author allow successful application of the "Kiev-16" movie-camera jointly with the fibrogastroscopes produced by Olympus Co without camera, for cinema and photodocumentation.

  20. Eight-channel Kirkpatrick-Baez microscope for multiframe x-ray imaging diagnostics in laser plasma experiments.

    PubMed

    Yi, Shengzhen; Zhang, Zhe; Huang, Qiushi; Zhang, Zhong; Mu, Baozhong; Wang, Zhanshan; Fang, Zhiheng; Wang, Wei; Fu, Sizu

    2016-10-01

    Because grazing-incidence Kirkpatrick-Baez (KB) microscopes have better resolution and collection efficiency than pinhole cameras, they have been widely used for x-ray imaging diagnostics of laser inertial confinement fusion. The assembly and adjustment of a multichannel KB microscope must meet stringent requirements for image resolution and reproducible alignment. In the present study, an eight-channel KB microscope was developed for diagnostics by imaging self-emission x-rays with a framing camera at the Shenguang-II Update (SGII-Update) laser facility. A consistent object field of view is ensured in the eight channels using an assembly method based on conical reference cones, which also allow the intervals between the eight images to be tuned to couple with the microstrips of the x-ray framing camera. The eight-channel KB microscope was adjusted via real-time x-ray imaging experiments in the laboratory. This paper describes the details of the eight-channel KB microscope, its optical and multilayer design, the assembly and alignment methods, and results of imaging in the laboratory and at the SGII-Update.

  1. Synchrotron emission diagnostic of full-orbit kinetic simulations of runaway electrons in tokamaks plasmas

    NASA Astrophysics Data System (ADS)

    Carbajal Gomez, Leopoldo; Del-Castillo-Negrete, Diego

    2017-10-01

    Developing avoidance or mitigation strategies of runaway electrons (RE) for the safe operation of ITER is imperative. Synchrotron radiation (SR) of RE is routinely used in current tokamak experiments to diagnose RE. We present the results of a newly developed camera diagnostic of SR for full-orbit kinetic simulations of RE in DIII-D-like plasmas that simultaneously includes: full-orbit effects, information of the spectral and angular distribution of SR of each electron, and basic geometric optics of a camera. We observe a strong dependence of the SR measured by the camera on the pitch angle distribution of RE, namely we find that crescent shapes of the SR on the camera pictures relate to RE distributions with small pitch angles, while ellipse shapes relate to distributions of RE with larger pitch angles. A weak dependence of the SR measured by the camera with the RE energy, value of the q-profile at the edge, and the chosen range of wavelengths is found. Furthermore, we observe that oversimplifying the angular distribution of the SR changes the synchrotron spectra and overestimates its amplitude. Research sponsored by the LDRD Program of ORNL, managed by UT-Battelle, LLC, for the U. S. DoE.

  2. Improved Fast, Deep Record Length, Time-Resolved Visible Spectroscopy of Plasmas Using Fiber Grids

    NASA Astrophysics Data System (ADS)

    Brockington, S.; Case, A.; Cruz, E.; Williams, A.; Witherspoon, F. D.; Horton, R.; Klauser, R.; Hwang, D.

    2017-10-01

    HyperV Technologies is developing a fiber-coupled, deep record-length, low-light camera head for performing high time resolution spectroscopy on visible emission from plasma events. By coupling the output of a spectrometer to an imaging fiber bundle connected to a bank of amplified silicon photomultipliers, time-resolved spectroscopic imagers of 100 to 1,000 pixels can be constructed. A second generation prototype 32-pixel spectroscopic imager employing this technique was constructed and successfully tested at the University of California at Davis Compact Toroid Injection Experiment (CTIX). Pixel performance of 10 Megaframes/sec with record lengths of up to 256,000 frames ( 25.6 milliseconds) were achieved. Pixel resolution was 12 bits. Pixel pitch can be refined by using grids of 100 μm to 1000 μm diameter fibers. Experimental results will be discussed, along with future plans for this diagnostic. Work supported by USDOE SBIR Grant DE-SC0013801.

  3. Gamma-ray spectroscopy at MHz counting rates with a compact LaBr3 detector and silicon photomultipliers for fusion plasma applications.

    PubMed

    Nocente, M; Rigamonti, D; Perseo, V; Tardocchi, M; Boltruczyk, G; Broslawski, A; Cremona, A; Croci, G; Gosk, M; Kiptily, V; Korolczuk, S; Mazzocco, M; Muraro, A; Strano, E; Zychor, I; Gorini, G

    2016-11-01

    Gamma-ray spectroscopy measurements at MHz counting rates have been carried out, for the first time, with a compact spectrometer based on a LaBr 3 scintillator and silicon photomultipliers. The instrument, which is also insensitive to magnetic fields, has been developed in view of the upgrade of the gamma-ray camera diagnostic for α particle measurements in deuterium-tritium plasmas of the Joint European Torus. Spectra were measured up to 2.9 MHz with a projected energy resolution of 3%-4% in the 3-5 MeV range, of interest for fast ion physics studies in fusion plasmas. The results reported here pave the way to first time measurements of the confined α particle profile in high power plasmas of the next deuterium-tritium campaign at the Joint European Torus.

  4. Coincidence velocity map imaging using Tpx3Cam, a time stamping optical camera with 1.5 ns timing resolution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Arthur; van Beuzekom, Martin; Bouwens, Bram

    Here, we demonstrate a coincidence velocity map imaging apparatus equipped with a novel time-stamping fast optical camera, Tpx3Cam, whose high sensitivity and nanosecond timing resolution allow for simultaneous position and time-of-flight detection. This single detector design is simple, flexible, and capable of highly differential measurements. We show detailed characterization of the camera and its application in strong field ionization experiments.

  5. Coincidence velocity map imaging using Tpx3Cam, a time stamping optical camera with 1.5 ns timing resolution

    DOE PAGES

    Zhao, Arthur; van Beuzekom, Martin; Bouwens, Bram; ...

    2017-11-07

    Here, we demonstrate a coincidence velocity map imaging apparatus equipped with a novel time-stamping fast optical camera, Tpx3Cam, whose high sensitivity and nanosecond timing resolution allow for simultaneous position and time-of-flight detection. This single detector design is simple, flexible, and capable of highly differential measurements. We show detailed characterization of the camera and its application in strong field ionization experiments.

  6. SeaVipers- Computer Vision and Inertial Position/Reference Sensor System (CVIPRSS)

    DTIC Science & Technology

    2015-08-01

    uses an Inertial Measurement Unit (IMU) to detect changes in roll , pitch, and yaw (x-, y-, and z-axis movement). We use a 9DOF Razor IMU from SparkFun... inertial measurement unit (IMU) and cameras that are hardware synchronized to provide close coupling. Several fast food companies, Internet giants like...light cameras [32]. 4.1.4 Inertial Measurement Unit To assist the PTU in video stabilization for the camera and aiming the rangefinder, Sea- Vipers

  7. Reconstruction of recycling flux from synthetic camera images, evaluated for the Wendelstein 7-X startup limiter

    NASA Astrophysics Data System (ADS)

    Frerichs, H.; Effenberg, F.; Feng, Y.; Schmitz, O.; Stephey, L.; Reiter, D.; Börner, P.; The W7-X Team

    2017-12-01

    The interpretation of spectroscopic measurements in the edge region of high-temperature plasmas can be guided by modeling with the EMC3-EIRENE code. A versatile synthetic diagnostic module, initially developed for the generation of synthetic camera images, has been extended for the evaluation of the inverse problem in which the observable photon flux is related back to the originating particle flux (recycling). An application of this synthetic diagnostic to the startup phase (inboard) limiter in Wendelstein 7-X (W7-X) is presented, and reconstruction of recycling from synthetic observation of \\renewcommand{\

  8. Fast noninvasive eye-tracking and eye-gaze determination for biomedical and remote monitoring applications

    NASA Astrophysics Data System (ADS)

    Talukder, Ashit; Morookian, John M.; Monacos, Steve P.; Lam, Raymond K.; Lebaw, C.; Bond, A.

    2004-04-01

    Eyetracking is one of the latest technologies that has shown potential in several areas including human-computer interaction for people with and without disabilities, and for noninvasive monitoring, detection, and even diagnosis of physiological and neurological problems in individuals. Current non-invasive eyetracking methods achieve a 30 Hz rate with possibly low accuracy in gaze estimation, that is insufficient for many applications. We propose a new non-invasive visual eyetracking system that is capable of operating at speeds as high as 6-12 KHz. A new CCD video camera and hardware architecture is used, and a novel fast image processing algorithm leverages specific features of the input CCD camera to yield a real-time eyetracking system. A field programmable gate array (FPGA) is used to control the CCD camera and execute the image processing operations. Initial results show the excellent performance of our system under severe head motion and low contrast conditions.

  9. Recent H- diagnostics, plasma simulations, and 2X scaled Penning ion source developments at the Rutherford Appleton Laboratory

    NASA Astrophysics Data System (ADS)

    Lawrie, S. R.; Faircloth, D. C.; Smith, J. D.; Sarmento, T. M.; Whitehead, M. O.; Wood, T.; Perkins, M.; Macgregor, J.; Abel, R.

    2018-05-01

    A vessel for extraction and source plasma analyses is being used for Penning H- ion source development at the Rutherford Appleton Laboratory. A new set of optical elements including an einzel lens has been installed, which transports over 80 mA of H- beam successfully. Simultaneously, a 2X scaled Penning source has been developed to reduce cathode power density. The 2X source is now delivering a 65 mA H- ion beam at 10% duty factor, meeting its design criteria. The long-term viability of the einzel lens and 2X source is now being evaluated, so new diagnostic devices have been installed. A pair of electrostatic deflector plates is used to correct beam misalignment and perform fast chopping, with a voltage rise time of 24 ns. A suite of four quartz crystal microbalances has shown that the cesium flux in the vacuum vessel is only increased by a factor of two, despite the absence of a dedicated cold trap. Finally, an infrared camera has demonstrated good agreement with thermal simulations but has indicated unexpected heating due to beam loss on the downstream electrode. These types of diagnostics are suitable for monitoring all operational ion sources. In addition to experimental campaigns and new diagnostic tools, the high-performance VSim and COMSOL software packages are being used for plasma simulations of two novel ion thrusters for space propulsion applications. In parallel, a VSim framework has been established to include arbitrary temperature and cesium fields to allow the modeling of surface physics in H- ion sources.

  10. FAST CHOPPER BUILDING, TRA665. DETAIL OF STEEL DOOR ENTRY TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FAST CHOPPER BUILDING, TRA-665. DETAIL OF STEEL DOOR ENTRY TO LOWER LEVEL. CAMERA FACING NORTH. INL NEGATIVE NO. HD42-1. Mike Crane, Photographer, 3/2004 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  11. Pole Photogrammetry with AN Action Camera for Fast and Accurate Surface Mapping

    NASA Astrophysics Data System (ADS)

    Gonçalves, J. A.; Moutinho, O. F.; Rodrigues, A. C.

    2016-06-01

    High resolution and high accuracy terrain mapping can provide height change detection for studies of erosion, subsidence or land slip. A UAV flying at a low altitude above the ground, with a compact camera, acquires images with resolution appropriate for these change detections. However, there may be situations where different approaches may be needed, either because higher resolution is required or the operation of a drone is not possible. Pole photogrammetry, where a camera is mounted on a pole, pointing to the ground, is an alternative. This paper describes a very simple system of this kind, created for topographic change detection, based on an action camera. These cameras have high quality and very flexible image capture. Although radial distortion is normally high, it can be treated in an auto-calibration process. The system is composed by a light aluminium pole, 4 meters long, with a 12 megapixel GoPro camera. Average ground sampling distance at the image centre is 2.3 mm. The user moves along a path, taking successive photos, with a time lapse of 0.5 or 1 second, and adjusting the speed in order to have an appropriate overlap, with enough redundancy for 3D coordinate extraction. Marked ground control points are surveyed with GNSS for precise georeferencing of the DSM and orthoimage that are created by structure from motion processing software. An average vertical accuracy of 1 cm could be achieved, which is enough for many applications, for example for soil erosion. The GNSS survey in RTK mode with permanent stations is now very fast (5 seconds per point), which results, together with the image collection, in a very fast field work. If an improved accuracy is needed, since image resolution is 1/4 cm, it can be achieved using a total station for the control point survey, although the field work time increases.

  12. A Robust In-Situ Warp-Correction Algorithm For VISAR Streak Camera Data at the National Ignition Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Labaria, George R.; Warrick, Abbie L.; Celliers, Peter M.

    2015-01-12

    The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory is a 192-beam pulsed laser system for high-energy-density physics experiments. Sophisticated diagnostics have been designed around key performance metrics to achieve ignition. The Velocity Interferometer System for Any Reflector (VISAR) is the primary diagnostic for measuring the timing of shocks induced into an ignition capsule. The VISAR system utilizes three streak cameras; these streak cameras are inherently nonlinear and require warp corrections to remove these nonlinear effects. A detailed calibration procedure has been developed with National Security Technologies (NSTec) and applied to the camera correction analysis in production. However,more » the camera nonlinearities drift over time, affecting the performance of this method. An in-situ fiber array is used to inject a comb of pulses to generate a calibration correction in order to meet the timing accuracy requirements of VISAR. We develop a robust algorithm for the analysis of the comb calibration images to generate the warp correction that is then applied to the data images. Our algorithm utilizes the method of thin-plate splines (TPS) to model the complex nonlinear distortions in the streak camera data. In this paper, we focus on the theory and implementation of the TPS warp-correction algorithm for the use in a production environment.« less

  13. Improved signal to noise ratio and sensitivity of an infrared imaging video bolometer on large helical device by using an infrared periscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pandya, Shwetang N., E-mail: pandya.shwetang@LHD.nifs.ac.jp; Sano, Ryuichi; Peterson, Byron J.

    An Infrared imaging Video Bolometer (IRVB) diagnostic is currently being used in the Large Helical Device (LHD) for studying the localization of radiation structures near the magnetic island and helical divertor X-points during plasma detachment and for 3D tomography. This research demands high signal to noise ratio (SNR) and sensitivity to improve the temporal resolution for studying the evolution of radiation structures during plasma detachment and a wide IRVB field of view (FoV) for tomography. Introduction of an infrared periscope allows achievement of a higher SNR and higher sensitivity, which in turn, permits a twofold improvement in the temporal resolutionmore » of the diagnostic. Higher SNR along with wide FoV is achieved simultaneously by reducing the separation of the IRVB detector (metal foil) from the bolometer's aperture and the LHD plasma. Altering the distances to meet the aforesaid requirements results in an increased separation between the foil and the IR camera. This leads to a degradation of the diagnostic performance in terms of its sensitivity by 1.5-fold. Using an infrared periscope to image the IRVB foil results in a 7.5-fold increase in the number of IR camera pixels imaging the foil. This improves the IRVB sensitivity which depends on the square root of the number of IR camera pixels being averaged per bolometer channel. Despite the slower f-number (f/# = 1.35) and reduced transmission (τ{sub 0} = 89%, due to an increased number of lens elements) for the periscope, the diagnostic with an infrared periscope operational on LHD has improved in terms of sensitivity and SNR by a factor of 1.4 and 4.5, respectively, as compared to the original diagnostic without a periscope (i.e., IRVB foil being directly imaged by the IR camera through conventional optics). The bolometer's field of view has also increased by two times. The paper discusses these improvements in apt details.« less

  14. Vacuum compatible miniature CCD camera head

    DOEpatents

    Conder, Alan D.

    2000-01-01

    A charge-coupled device (CCD) camera head which can replace film for digital imaging of visible light, ultraviolet radiation, and soft to penetrating x-rays, such as within a target chamber where laser produced plasmas are studied. The camera head is small, capable of operating both in and out of a vacuum environment, and is versatile. The CCD camera head uses PC boards with an internal heat sink connected to the chassis for heat dissipation, which allows for close(0.04" for example) stacking of the PC boards. Integration of this CCD camera head into existing instrumentation provides a substantial enhancement of diagnostic capabilities for studying high energy density plasmas, for a variety of military industrial, and medical imaging applications.

  15. Neuromorphic Event-Based 3D Pose Estimation

    PubMed Central

    Reverter Valeiras, David; Orchard, Garrick; Ieng, Sio-Hoi; Benosman, Ryad B.

    2016-01-01

    Pose estimation is a fundamental step in many artificial vision tasks. It consists of estimating the 3D pose of an object with respect to a camera from the object's 2D projection. Current state of the art implementations operate on images. These implementations are computationally expensive, especially for real-time applications. Scenes with fast dynamics exceeding 30–60 Hz can rarely be processed in real-time using conventional hardware. This paper presents a new method for event-based 3D object pose estimation, making full use of the high temporal resolution (1 μs) of asynchronous visual events output from a single neuromorphic camera. Given an initial estimate of the pose, each incoming event is used to update the pose by combining both 3D and 2D criteria. We show that the asynchronous high temporal resolution of the neuromorphic camera allows us to solve the problem in an incremental manner, achieving real-time performance at an update rate of several hundreds kHz on a conventional laptop. We show that the high temporal resolution of neuromorphic cameras is a key feature for performing accurate pose estimation. Experiments are provided showing the performance of the algorithm on real data, including fast moving objects, occlusions, and cases where the neuromorphic camera and the object are both in motion. PMID:26834547

  16. Adaptive Monocular Visual-Inertial SLAM for Real-Time Augmented Reality Applications in Mobile Devices.

    PubMed

    Piao, Jin-Chun; Kim, Shin-Dug

    2017-11-07

    Simultaneous localization and mapping (SLAM) is emerging as a prominent issue in computer vision and next-generation core technology for robots, autonomous navigation and augmented reality. In augmented reality applications, fast camera pose estimation and true scale are important. In this paper, we present an adaptive monocular visual-inertial SLAM method for real-time augmented reality applications in mobile devices. First, the SLAM system is implemented based on the visual-inertial odometry method that combines data from a mobile device camera and inertial measurement unit sensor. Second, we present an optical-flow-based fast visual odometry method for real-time camera pose estimation. Finally, an adaptive monocular visual-inertial SLAM is implemented by presenting an adaptive execution module that dynamically selects visual-inertial odometry or optical-flow-based fast visual odometry. Experimental results show that the average translation root-mean-square error of keyframe trajectory is approximately 0.0617 m with the EuRoC dataset. The average tracking time is reduced by 7.8%, 12.9%, and 18.8% when different level-set adaptive policies are applied. Moreover, we conducted experiments with real mobile device sensors, and the results demonstrate the effectiveness of performance improvement using the proposed method.

  17. High speed Infrared imaging method for observation of the fast varying temperature phenomena

    NASA Astrophysics Data System (ADS)

    Moghadam, Reza; Alavi, Kambiz; Yuan, Baohong

    With new improvements in high-end commercial R&D camera technologies many challenges have been overcome for exploring the high-speed IR camera imaging. The core benefits of this technology is the ability to capture fast varying phenomena without image blur, acquire enough data to properly characterize dynamic energy, and increase the dynamic range without compromising the number of frames per second. This study presents a noninvasive method for determining the intensity field of a High Intensity Focused Ultrasound Device (HIFU) beam using Infrared imaging. High speed Infrared camera was placed above the tissue-mimicking material that was heated by HIFU with no other sensors present in the HIFU axial beam. A MATLAB simulation code used to perform a finite-element solution to the pressure wave propagation and heat equations within the phantom and temperature rise to the phantom was computed. Three different power levels of HIFU transducers were tested and the predicted temperature increase values were within about 25% of IR measurements. The fundamental theory and methods developed in this research can be used to detect fast varying temperature phenomena in combination with the infrared filters.

  18. Study of the effect of sawteeth on fast ions and neutron emission in MAST using a neutron camera

    NASA Astrophysics Data System (ADS)

    Cecconello, M.; Sperduti, A.; the MAST team

    2018-05-01

    The effect of the sawtooth instability on the confinement of fast ions on MAST, and the impact it has on the neutron emission, has been studied in detail using the TRANSP/NUBEAM codes coupled to a full orbit following code. The sawtooth models in TRANSP/NUBEAM indicate that, on MAST, passing and trapped fast ions are redistributed in approximately equal number and on a level that is consistent with the observations. It has not been possible to discriminate between the different sawtooth models since their predictions are all compatible with the neutron camera observations. Full orbit calculations of the fast ion motion have been used to estimate the characteristic time scales and energy thresholds that according to theoretical predictions govern the fast ions redistribution: no energy threshold for the redistribution for either passing and trapped fast ions was found. The characteristic times have, however, frequencies that are comparable with the frequencies of a m = 1, n = 1 perturbation and its harmonics with toroidal mode numbers n=2, \\ldots , 4, suggesting that on spherical tokamaks, in addition to the classical sawtooth-induced transport mechanisms of fast ions by attachment to the evolving perturbation and the associated E × B drift, a resonance mechanism between the m = 1 perturbation and the fast ions orbits might be at play.

  19. The JET diagnostic fast central acquisition and trigger system (abstract)

    NASA Astrophysics Data System (ADS)

    Edwards, A. W.; Blackler, K.

    1995-01-01

    Most plasma physics diagnostics sample at a fixed frequency that is normally matched to available memory limits. This technique is not appropriate for long pulse machines such as JET where sampling frequencies of hundreds of kHz are required to diagnose very fast events. As a result of work using real-time event selection within the previous JET soft x-ray diagnostic, a single data acquisition and event triggering system for all suitable fast diagnostics, the fast central acquisition and trigger system (Fast CATS), has been developed for JET. The front-end analog-to-digital conversion (ADC) part samples all channels at 250 kHz, with a 100 kHz pass band and a stop band of 125 kHz. The back-end data collection system is based around Texas Instruments TMS320C40 microprocessors. Within this system, two levels of trigger algorithms are able to evaluate data. The first level typically analyzes data on a per diagnostic and individual channel basis. The second level looks at the data from one or more diagnostics in a window around the time of interest flagged by the first level system. Selection criteria defined by the diagnosticians are then imposed on the results from the second level to decide whether that data should be kept. The use of such a system involving intelligent real time trigger algorithms and fast data analysis will improve both the quantity and quality of JET diagnostic data, while providing valuable input to the design of data acquisition systems for very long pulse machines such as ITER. This paper will give an overview of the various elements of this new system. In addition, first results from this system following the restart of JET operation will be presented.

  20. Automatic multi-camera calibration for deployable positioning systems

    NASA Astrophysics Data System (ADS)

    Axelsson, Maria; Karlsson, Mikael; Rudner, Staffan

    2012-06-01

    Surveillance with automated positioning and tracking of subjects and vehicles in 3D is desired in many defence and security applications. Camera systems with stereo or multiple cameras are often used for 3D positioning. In such systems, accurate camera calibration is needed to obtain a reliable 3D position estimate. There is also a need for automated camera calibration to facilitate fast deployment of semi-mobile multi-camera 3D positioning systems. In this paper we investigate a method for automatic calibration of the extrinsic camera parameters (relative camera pose and orientation) of a multi-camera positioning system. It is based on estimation of the essential matrix between each camera pair using the 5-point method for intrinsically calibrated cameras. The method is compared to a manual calibration method using real HD video data from a field trial with a multicamera positioning system. The method is also evaluated on simulated data from a stereo camera model. The results show that the reprojection error of the automated camera calibration method is close to or smaller than the error for the manual calibration method and that the automated calibration method can replace the manual calibration.

  1. Pixel-based characterisation of CMOS high-speed camera systems

    NASA Astrophysics Data System (ADS)

    Weber, V.; Brübach, J.; Gordon, R. L.; Dreizler, A.

    2011-05-01

    Quantifying high-repetition rate laser diagnostic techniques for measuring scalars in turbulent combustion relies on a complete description of the relationship between detected photons and the signal produced by the detector. CMOS-chip based cameras are becoming an accepted tool for capturing high frame rate cinematographic sequences for laser-based techniques such as Particle Image Velocimetry (PIV) and Planar Laser Induced Fluorescence (PLIF) and can be used with thermographic phosphors to determine surface temperatures. At low repetition rates, imaging techniques have benefitted from significant developments in the quality of CCD-based camera systems, particularly with the uniformity of pixel response and minimal non-linearities in the photon-to-signal conversion. The state of the art in CMOS technology displays a significant number of technical aspects that must be accounted for before these detectors can be used for quantitative diagnostics. This paper addresses these issues.

  2. Recording the synchrotron radiation by a picosecond streak camera for bunch diagnostics in cyclic accelerators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vereshchagin, A K; Vorob'ev, N S; Gornostaev, P B

    2016-02-28

    A PS-1/S1 picosecond streak camera with a linear sweep is used to measure temporal characteristics of synchrotron radiation pulses on a damping ring (DR) at the Budker Institute of Nuclear Physics (BINP) of the Siberian Branch of the Russian Academy of Sciences (Novosibirsk). The data obtained allow a conclusion as to the formation processes of electron bunches and their 'quality' in the DR after injection from the linear accelerator. The expediency of employing the streak camera as a part of an optical diagnostic accelerator complex for adjusting the injection from a linear accelerator is shown. Discussed is the issue ofmore » designing a new-generation dissector with a time resolution up to a few picoseconds, which would allow implementation of a continuous bunch monitoring in the DR during mutual work with the electron-positron colliders at the BINP. (acoustooptics)« less

  3. Vapour Pressure and Adiabatic Cooling from Champagne: Slow-Motion Visualization of Gas Thermodynamics

    ERIC Educational Resources Information Center

    Vollmer, Michael; Mollmann, Klaus-Peter

    2012-01-01

    The recent introduction of inexpensive high-speed cameras offers a new experimental approach to many simple but fast-occurring events in physics. In this paper, the authors present two simple demonstration experiments recorded with high-speed cameras in the fields of gas dynamics and thermal physics. The experiments feature vapour pressure effects…

  4. Dust as a versatile matter for high-temperature plasma diagnostic.

    PubMed

    Wang, Zhehui; Ticos, Catalin M

    2008-10-01

    Dust varies from a few nanometers to a fraction of a millimeter in size. Dust also offers essentially unlimited choices in material composition and structure. The potential of dust for high-temperature plasma diagnostic is largely unfulfilled yet. The principles of dust spectroscopy to measure internal magnetic field, microparticle tracer velocimetry to measure plasma flow, and dust photometry to measure heat flux are described. Two main components of the different dust diagnostics are a dust injector and a dust imaging system. The dust injector delivers a certain number of dust grains into a plasma. The imaging system collects and selectively detects certain photons resulted from dust-plasma interaction. One piece of dust gives the local plasma quantity, a collection of dust grains together reveals either two-dimensional (using only one or two imaging cameras) or three-dimensional (using two or more imaging cameras) structures of the measured quantity. A generic conceptual design suitable for all three types of dust diagnostics is presented.

  5. Upgrade of the infrared camera diagnostics for the JET ITER-like wall divertor.

    PubMed

    Balboa, I; Arnoux, G; Eich, T; Sieglin, B; Devaux, S; Zeidner, W; Morlock, C; Kruezi, U; Sergienko, G; Kinna, D; Thomas, P D; Rack, M

    2012-10-01

    For the new ITER-like wall at JET, two new infrared diagnostics (KL9B, KL3B) have been installed. These diagnostics can operate between 3.5 and 5 μm and up to sampling frequencies of ∼20 kHz. KL9B and KL3B image the horizontal and vertical tiles of the divertor. The divertor tiles are tungsten coated carbon fiber composite except the central tile which is bulk tungsten and consists of lamella segments. The thermal emission between lamellae affects the surface temperature measurement and therefore KL9A has been upgraded to achieve a higher spatial resolution (by a factor of 2). A technical description of KL9A, KL9B, and KL3B and cross correlation with a near infrared camera and a two-color pyrometer is presented.

  6. Use of hyperspectral imaging technology to develop a diagnostic support system for gastric cancer

    NASA Astrophysics Data System (ADS)

    Goto, Atsushi; Nishikawa, Jun; Kiyotoki, Shu; Nakamura, Munetaka; Nishimura, Junichi; Okamoto, Takeshi; Ogihara, Hiroyuki; Fujita, Yusuke; Hamamoto, Yoshihiko; Sakaida, Isao

    2015-01-01

    Hyperspectral imaging (HSI) is a new technology that obtains spectroscopic information and renders it in image form. This study examined the difference in the spectral reflectance (SR) of gastric tumors and normal mucosa recorded with a hyperspectral camera equipped with HSI technology and attempted to determine the specific wavelength that is useful for the diagnosis of gastric cancer. A total of 104 gastric tumors removed by endoscopic submucosal dissection from 96 patients at Yamaguchi University Hospital were recorded using a hyperspectral camera. We determined the optimal wavelength and the cut-off value for differentiating tumors from normal mucosa to establish a diagnostic algorithm. We also attempted to highlight tumors by image processing using the hyperspectral camera's analysis software. A wavelength of 770 nm and a cut-off value of 1/4 the corrected SR were selected as the respective optimal wavelength and cut-off values. The rates of sensitivity, specificity, and accuracy of the algorithm's diagnostic capability were 71%, 98%, and 85%, respectively. It was possible to enhance tumors by image processing at the 770-nm wavelength. HSI can be used to measure the SR in gastric tumors and to differentiate between tumorous and normal mucosa.

  7. Gamma-camera 18F-FDG PET in diagnosis and staging of patients presenting with suspected lung cancer and comparison with dedicated PET.

    PubMed

    Oturai, Peter S; Mortensen, Jann; Enevoldsen, Henriette; Eigtved, Annika; Backer, Vibeke; Olesen, Knud P; Nielsen, Henrik W; Hansen, Hanne; Stentoft, Poul; Friberg, Lars

    2004-08-01

    It is not clear whether high-quality coincidence gamma-PET (gPET) cameras can provide clinical data comparable with data obtained with dedicated PET (dPET) cameras in the primary diagnostic work-up of patients with suspected lung cancer. This study focuses on 2 main issues: direct comparison between foci resolved with the 2 different PET scanners and the diagnostic accuracy compared with final diagnosis determined by the combined information from all other investigations and clinical follow-up. Eighty-six patients were recruited to this study through a routine diagnostic program. They all had changes on their chest radiographs, suggesting malignant lung tumor. In addition to the standard diagnostic program, each patient had 2 PET scans that were performed on the same day. After administration of 419 MBq (range = 305-547 MBq) (18)F-FDG, patients were scanned in a dedicated PET scanner about 1 h after FDG administration and in a dual-head coincidence gamma-camera about 3 h after tracer injection. Images from the 2 scans were evaluated in a blinded set-up and compared with the final outcome. Malignant intrathoracic disease was found in 52 patients, and 47 patients had primary lung cancers. dPET detected all patients as having malignancies (sensitivity, 100%; specificity, 50%), whereas gPET missed one patient (sensitivity, 98%; specificity, 56%). For evaluating regional lymph node involvement, sensitivity and specificity rates were 78% and 84% for dPET and 61% and 90% for gPET, respectively. When comparing the 2 PET techniques with clinical tumor stage (TNM), full agreement was obtained in 64% of the patients (Cohen's kappa = 0.56). Comparing categorization of the patients into clinical relevant stages (no malignancy/malignancy suitable for treatment with curative intent/nontreatable malignancy), resulted in full agreement in 81% (Cohen's kappa = 0.71) of patients. Comparing results from a recent generation of gPET cameras obtained about 2 h later than those of dPET, there was a fairly good agreement with regard to detecting primary lung tumors but slightly reduced sensitivity in detecting smaller malignant lesions such as lymph nodes. Depending on the population to be investigated, and if dPET is not available, gPET might provide significant diagnostic information in patients in whom lung cancer is suspected.

  8. ITER Plasma at Ion Cyclotron Frequency Domain: The Fusion Alpha Particles Diagnostics Based on the Stimulated Raman Scattering of Fast Magnetosonic Wave off High Harmonic Ion Bernstein Modes

    NASA Astrophysics Data System (ADS)

    Stefan, V. Alexander

    2014-10-01

    A novel method for alpha particle diagnostics is proposed. The theory of stimulated Raman scattering, SRS, of the fast wave and ion Bernstein mode, IBM, turbulence in multi-ion species plasmas, (Stefan University Press, La Jolla, CA, 2008). is utilized for the diagnostics of fast ions, (4)He (+2), in ITER plasmas. Nonlinear Landau damping of the IBM on fast ions near the plasma edge leads to the space-time changes in the turbulence level, (inverse alpha particle channeling). The space-time monitoring of the IBM turbulence via the SRS techniques may prove efficient for the real time study of the fast ion velocity distribution function, spatial distribution, and transport. Supported by Nikola Tesla Labs., La Jolla, CA 92037.

  9. Obscura telescope with a MEMS micromirror array for space observation of transient luminous phenomena or fast-moving objects.

    PubMed

    Park, J H; Garipov, G K; Jeon, J A; Khrenov, B A; Kim, J E; Kim, M; Kim, Y K; Lee, C-H; Lee, J; Na, G W; Nam, S; Park, I H; Park, Y-S

    2008-12-08

    We introduce a novel telescope consisting of a pinhole-like camera with rotatable MEMS micromirrors substituting for pinholes. The design is ideal for observations of transient luminous phenomena or fast-moving objects, such as upper atmospheric lightning and bright gamma ray bursts. The advantage of the MEMS "obscura telescope" over conventional cameras is that it is capable both of searching for events over a wide field of view, and fast zooming to allow detailed investigation of the structure of events. It is also able to track the triggering object to investigate its space-time development, and to center the interesting portion of the image on the photodetector array. We present the proposed system and the test results for the MEMS obscura telescope which has a field of view of 11.3 degrees, sixteen times zoom-in and tracking within 1 ms. (c) 2008 Optical Society of America

  10. Printed circuit board for a CCD camera head

    DOEpatents

    Conder, Alan D.

    2002-01-01

    A charge-coupled device (CCD) camera head which can replace film for digital imaging of visible light, ultraviolet radiation, and soft to penetrating x-rays, such as within a target chamber where laser produced plasmas are studied. The camera head is small, capable of operating both in and out of a vacuum environment, and is versatile. The CCD camera head uses PC boards with an internal heat sink connected to the chassis for heat dissipation, which allows for close (0.04" for example) stacking of the PC boards. Integration of this CCD camera head into existing instrumentation provides a substantial enhancement of diagnostic capabilities for studying high energy density plasmas, for a variety of military industrial, and medical imaging applications.

  11. Self-Organized Multi-Camera Network for a Fast and Easy Deployment of Ubiquitous Robots in Unknown Environments

    PubMed Central

    Canedo-Rodriguez, Adrián; Iglesias, Roberto; Regueiro, Carlos V.; Alvarez-Santos, Victor; Pardo, Xose Manuel

    2013-01-01

    To bring cutting edge robotics from research centres to social environments, the robotics community must start providing affordable solutions: the costs must be reduced and the quality and usefulness of the robot services must be enhanced. Unfortunately, nowadays the deployment of robots and the adaptation of their services to new environments are tasks that usually require several days of expert work. With this in view, we present a multi-agent system made up of intelligent cameras and autonomous robots, which is easy and fast to deploy in different environments. The cameras will enhance the robot perceptions and allow them to react to situations that require their services. Additionally, the cameras will support the movement of the robots. This will enable our robots to navigate even when there are not maps available. The deployment of our system does not require expertise and can be done in a short period of time, since neither software nor hardware tuning is needed. Every system task is automatic, distributed and based on self-organization processes. Our system is scalable, robust, and flexible to the environment. We carried out several real world experiments, which show the good performance of our proposal. PMID:23271604

  12. Self-organized multi-camera network for a fast and easy deployment of ubiquitous robots in unknown environments.

    PubMed

    Canedo-Rodriguez, Adrián; Iglesias, Roberto; Regueiro, Carlos V; Alvarez-Santos, Victor; Pardo, Xose Manuel

    2012-12-27

    To bring cutting edge robotics from research centres to social environments, the robotics community must start providing affordable solutions: the costs must be reduced and the quality and usefulness of the robot services must be enhanced. Unfortunately, nowadays the deployment of robots and the adaptation of their services to new environments are tasks that usually require several days of expert work. With this in view, we present a multi-agent system made up of intelligent cameras and autonomous robots, which is easy and fast to deploy in different environments. The cameras will enhance the robot perceptions and allow them to react to situations that require their services. Additionally, the cameras will support the movement of the robots. This will enable our robots to navigate even when there are not maps available. The deployment of our system does not require expertise and can be done in a short period of time, since neither software nor hardware tuning is needed. Every system task is automatic, distributed and based on self-organization processes. Our system is scalable, robust, and flexible to the environment. We carried out several real world experiments, which show the good performance of our proposal.

  13. Fast camera observations of injected and intrinsic dust in TEXTOR

    NASA Astrophysics Data System (ADS)

    Shalpegin, A.; Vignitchouk, L.; Erofeev, I.; Brochard, F.; Litnovsky, A.; Bozhenkov, S.; Bykov, I.; den Harder, N.; Sergienko, G.

    2015-12-01

    Stereoscopic fast camera observations of pre-characterized carbon and tungsten dust injection in TEXTOR are reported, along with the modelling of tungsten particle trajectories with MIGRAINe. Particle tracking analysis of the video data showed significant differences in dust dynamics: while carbon flakes were prone to agglomeration and explosive destruction, spherical tungsten particles followed quasi-inertial trajectories. Although this inertial nature prevented any validation of the force models used in MIGRAINe, comparisons between the experimental and simulated lifetimes provide a direct evidence of dust temperature overestimation in dust dynamics codes. Furthermore, wide-view observations of the TEXTOR interior revealed the main production mechanism of intrinsic carbon dust, as well as the location of probable dust remobilization sites.

  14. Enabling High Fidelity Measurements of Energy and Pitch Angle for Escaping Energetic Ions with a Fast Ion Loss Detector

    NASA Astrophysics Data System (ADS)

    Chaban, R.; Pace, D. C.; Marcy, G. R.; Taussig, D.

    2016-10-01

    Energetic ion losses must be minimized in burning plasmas to maintain fusion power, and existing tokamaks provide access to energetic ion parameter regimes that are relevant to burning machines. A new Fast Ion Loss Detector (FILD) probe on the DIII-D tokamak has been optimized to resolve beam ion losses across a range of 30 - 90 keV in energy and 40° to 80° in pitch angle, thereby providing valuable measurements during many different experiments. The FILD is a magnetic spectrometer; once inserted into the tokamak, the magnetic field allows energetic ions to pass through a collimating aperture and strike a scintillator plate that is imaged by a wide view camera and narrow view photomultiplier tubes (PMTs). The design involves calculating scintillator strike patterns while varying probe geometry. Calculated scintillator patterns are then used to design an optical system that allows adjustment of the focus regions for the 1 MS/s resolved PMTs. A synthetic diagnostic will be used to determine the energy and pitch angle resolution that can be attained in DIII-D experiments. Work supported in part by US DOE under the Science Undergraduate Laboratory Internship (SULI) program and under DE-FC02-04ER54698.

  15. Interpretation of fast-ion signals during beam modulation experiments

    DOE PAGES

    Heidbrink, W. W.; Collins, C. S.; Stagner, L.; ...

    2016-07-22

    Fast-ion signals produced by a modulated neutral beam are used to infer fast-ion transport. The measured quantity is the divergence of perturbed fast-ion flux from the phase-space volume measured by the diagnostic, ∇•more » $$\\bar{Γ}$$. Since velocity-space transport often contributes to this divergence, the phase-space sensitivity of the diagnostic (or “weight function”) plays a crucial role in the interpretation of the signal. The source and sink make major contributions to the signal but their effects are accurately modeled by calculations that employ an exponential decay term for the sink. Recommendations for optimal design of a fast-ion transport experiment are given, illustrated by results from DIII-D measurements of fast-ion transport by Alfv´en eigenmodes. Finally, the signal-to-noise ratio of the diagnostic, systematic uncertainties in the modeling of the source and sink, and the non-linearity of the perturbation all contribute to the error in ∇•$$\\bar{Γ}$$.« less

  16. Toward an image compression algorithm for the high-resolution electronic still camera

    NASA Technical Reports Server (NTRS)

    Nerheim, Rosalee

    1989-01-01

    Taking pictures with a camera that uses a digital recording medium instead of film has the advantage of recording and transmitting images without the use of a darkroom or a courier. However, high-resolution images contain an enormous amount of information and strain data-storage systems. Image compression will allow multiple images to be stored in the High-Resolution Electronic Still Camera. The camera is under development at Johnson Space Center. Fidelity of the reproduced image and compression speed are of tantamount importance. Lossless compression algorithms are fast and faithfully reproduce the image, but their compression ratios will be unacceptably low due to noise in the front end of the camera. Future efforts will include exploring methods that will reduce the noise in the image and increase the compression ratio.

  17. Understanding the Effect of Gas Dynamics in Plasma Gun Performance for Simulating Fusion Wall Response to Disruption Events

    NASA Astrophysics Data System (ADS)

    Riedel, Will; Underwood, Thomas; Righetti, Fabio; Cappelli, Mark

    2017-10-01

    In this work, the suitability of a pulsed coaxial plasma accelerator to simulate the interaction of edge-localized modes with plasma first wall materials is investigated. Experimental measurements derived from a suite of diagnostics are presented that focus on both the properties of the plasma flow and the manner in which such jets couple with material interfaces. Specific emphasis is placed on quantifying the variation in these properties using tungsten tokens exposed to the plasma plume as the gun volume is progressively filled with more neutral gas. These results are mapped to the operational dynamics of the gun via a time-resolved Schlieren cinematic visualization of the density gradient within the flow. Resulting videos indicate the existence of two distinct modes with vastly different characteristic timescales, spatial evolution, and plasma properties. Time resolved quantification of the associated plasma heat flux for both modes, including a range spanning 150 MW m-2 - 10 GW m-2, is presented using both a fast thermocouple gauge and an IR camera. Both diagnostics in conjunction with a heat transfer model provide an accurate description of the energy transfer dynamics and operational characteristics of plasma guns. This work is supported by the U.S. Department of Energy Stewardship Science Academic Program.

  18. Hardware Timestamping for an Image Acquisition System Based on FlexRIO and IEEE 1588 v2 Standard

    NASA Astrophysics Data System (ADS)

    Esquembri, S.; Sanz, D.; Barrera, E.; Ruiz, M.; Bustos, A.; Vega, J.; Castro, R.

    2016-02-01

    Current fusion devices usually implement distributed acquisition systems for the multiple diagnostics of their experiments. However, each diagnostic is composed by hundreds or even thousands of signals, including images from the vessel interior. These signals and images must be correctly timestamped, because all the information will be analyzed to identify plasma behavior using temporal correlations. For acquisition devices without synchronization mechanisms the timestamp is given by another device with timing capabilities when signaled by the first device. Later, each data should be related with its timestamp, usually via software. This critical action is unfeasible for software applications when sampling rates are high. In order to solve this problem this paper presents the implementation of an image acquisition system with real-time hardware timestamping mechanism. This is synchronized with a master clock using the IEEE 1588 v2 Precision Time Protocol (PTP). Synchronization, image acquisition and processing, and timestamping mechanisms are implemented using Field Programmable Gate Array (FPGA) and a timing card -PTP v2 synchronized. The system has been validated using a camera simulator streaming videos from fusion databases. The developed architecture is fully compatible with ITER Fast Controllers and has been integrated with EPICS to control and monitor the whole system.

  19. Personal medical information system using laser card

    NASA Astrophysics Data System (ADS)

    Cho, Seong H.; Kim, Keun Ho; Choi, Hyung-Sik; Park, Hyun Wook

    1996-04-01

    The well-known hospital information system (HIS) and the picture archiving and communication system (PACS) are typical applications of multimedia to medical area. This paper proposes a personal medical information save-and-carry system using a laser card. This laser card is very useful, especially in emergency situations, because the medical information in the laser card can be read at anytime and anywhere if there exists a laser card reader/writer. The contents of the laser card include the clinical histories of a patient such as clinical chart, exam result, diagnostic reports, images, and so on. The purpose of this system is not a primary diagnosis, but emergency reference of clinical history of the patient. This personal medical information system consists of a personal computer integrated with laser card reader/writer, color frame grabber, color CCD camera and a high resolution image scanner optionally. Window-based graphical user interface was designed for easy use. The laser card has relatively sufficient capacity to store the personal medical information, and has fast access speed to restore and load the data with a portable size as compact as a credit card. Database items of laser card provide the doctors with medical data such as laser card information, patient information, clinical information, and diagnostic result information.

  20. Electromagnetic diagnostics of ECR-Ion Sources plasmas: optical/X-ray imaging and spectroscopy

    NASA Astrophysics Data System (ADS)

    Mascali, D.; Castro, G.; Altana, C.; Caliri, C.; Mazzaglia, M.; Romano, F. P.; Leone, F.; Musumarra, A.; Naselli, E.; Reitano, R.; Torrisi, G.; Celona, L.; Cosentino, L. G.; Giarrusso, M.; Gammino, S.

    2017-12-01

    Magnetoplasmas in ECR-Ion Sources are excited from gaseous elements or vapours by microwaves in the range 2.45-28 GHz via Electron Cyclotron Resonance. A B-minimum, magnetohydrodynamic stable configuration is used for trapping the plasma. The values of plasma density, temperature and confinement times are typically ne= 1011-1013 cm-3, 01 eV

  1. FAST CHOPPER BUILDING, TRA665. CONTEXTUAL VIEW: CHOPPER BUILDING IN CENTER. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FAST CHOPPER BUILDING, TRA-665. CONTEXTUAL VIEW: CHOPPER BUILDING IN CENTER. MTR REACTOR SERVICES BUILDING,TRA-635, TO LEFT; MTR BUILDING TO RIGHT. CAMERA FACING WEST. INL NEGATIVE NO. HD42-1. Mike Crane, Photographer, 3/2004 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  2. Introducing minimum Fisher regularisation tomography to AXUV and soft x-ray diagnostic systems of the COMPASS tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mlynar, J.; Weinzettl, V.; Imrisek, M.

    2012-10-15

    The contribution focuses on plasma tomography via the minimum Fisher regularisation (MFR) algorithm applied on data from the recently commissioned tomographic diagnostics on the COMPASS tokamak. The MFR expertise is based on previous applications at Joint European Torus (JET), as exemplified in a new case study of the plasma position analyses based on JET soft x-ray (SXR) tomographic reconstruction. Subsequent application of the MFR algorithm on COMPASS data from cameras with absolute extreme ultraviolet (AXUV) photodiodes disclosed a peaked radiating region near the limiter. Moreover, its time evolution indicates transient plasma edge cooling following a radial plasma shift. In themore » SXR data, MFR demonstrated that a high resolution plasma positioning independent of the magnetic diagnostics would be possible provided that a proper calibration of the cameras on an x-ray source is undertaken.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaffney, Kelly

    Movies have transformed our perception of the world. With slow motion photography, we can see a hummingbird flap its wings, and a bullet pierce an apple. The remarkably small and extremely fast molecular world that determines how your body functions cannot be captured with even the most sophisticated movie camera today. To see chemistry in real time requires a camera capable of seeing molecules that are one ten billionth of a foot with a frame rate of 10 trillion frames per second! SLAC has embarked on the construction of just such a camera. Please join me as I discuss howmore » this molecular movie camera will work and how it will change our perception of the molecular world.« less

  4. Adaptive Monocular Visual–Inertial SLAM for Real-Time Augmented Reality Applications in Mobile Devices

    PubMed Central

    Piao, Jin-Chun; Kim, Shin-Dug

    2017-01-01

    Simultaneous localization and mapping (SLAM) is emerging as a prominent issue in computer vision and next-generation core technology for robots, autonomous navigation and augmented reality. In augmented reality applications, fast camera pose estimation and true scale are important. In this paper, we present an adaptive monocular visual–inertial SLAM method for real-time augmented reality applications in mobile devices. First, the SLAM system is implemented based on the visual–inertial odometry method that combines data from a mobile device camera and inertial measurement unit sensor. Second, we present an optical-flow-based fast visual odometry method for real-time camera pose estimation. Finally, an adaptive monocular visual–inertial SLAM is implemented by presenting an adaptive execution module that dynamically selects visual–inertial odometry or optical-flow-based fast visual odometry. Experimental results show that the average translation root-mean-square error of keyframe trajectory is approximately 0.0617 m with the EuRoC dataset. The average tracking time is reduced by 7.8%, 12.9%, and 18.8% when different level-set adaptive policies are applied. Moreover, we conducted experiments with real mobile device sensors, and the results demonstrate the effectiveness of performance improvement using the proposed method. PMID:29112143

  5. Fast camera imaging of dust in the DIII-D tokamak

    NASA Astrophysics Data System (ADS)

    Yu, J. H.; Rudakov, D. L.; Pigarov, A. Yu.; Smirnov, R. D.; Brooks, N. H.; Muller, S. H.; West, W. P.

    2009-06-01

    Naturally occurring and injected dust particles are observed in the DIII-D tokamak in the outer midplane scrape-off-layer (SOL) using a visible fast-framing camera, and the size of dust particles is estimated using the observed particle lifetime and theoretical ablation rate of a carbon sphere. Using this method, the lower limit of detected dust radius is ˜3 μm and particles with inferred radius as large as ˜1 mm are observed. Dust particle 2D velocities range from approximately 10 to 300 m/s with velocities inversely correlated with dust size. Pre-characterized 2-4 μm diameter diamond dust particles are introduced at the lower divertor in an ELMing H-mode discharge using the divertor materials evaluation system (DiMES), and these particles are found to be at the lower size limit of detection using the camera with resolution of ˜0.2 cm 2 per pixel and exposure time of 330 μs.

  6. Adaptive Wiener filter super-resolution of color filter array images.

    PubMed

    Karch, Barry K; Hardie, Russell C

    2013-08-12

    Digital color cameras using a single detector array with a Bayer color filter array (CFA) require interpolation or demosaicing to estimate missing color information and provide full-color images. However, demosaicing does not specifically address fundamental undersampling and aliasing inherent in typical camera designs. Fast non-uniform interpolation based super-resolution (SR) is an attractive approach to reduce or eliminate aliasing and its relatively low computational load is amenable to real-time applications. The adaptive Wiener filter (AWF) SR algorithm was initially developed for grayscale imaging and has not previously been applied to color SR demosaicing. Here, we develop a novel fast SR method for CFA cameras that is based on the AWF SR algorithm and uses global channel-to-channel statistical models. We apply this new method as a stand-alone algorithm and also as an initialization image for a variational SR algorithm. This paper presents the theoretical development of the color AWF SR approach and applies it in performance comparisons to other SR techniques for both simulated and real data.

  7. NEUTRON RADIATION DAMAGE IN CCD CAMERAS AT JOINT EUROPEAN TORUS (JET).

    PubMed

    Milocco, Alberto; Conroy, Sean; Popovichev, Sergey; Sergienko, Gennady; Huber, Alexander

    2017-10-26

    The neutron and gamma radiations in large fusion reactors are responsible for damage to charged couple device (CCD) cameras deployed for applied diagnostics. Based on the ASTM guide E722-09, the 'equivalent 1 MeV neutron fluence in silicon' was calculated for a set of CCD cameras at the Joint European Torus. Such evaluations would be useful to good practice in the operation of the video systems. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Towards Modernizing the Characterization of Shock and Detonation Physics Performance via Novel Diagnostics and Tests

    NASA Astrophysics Data System (ADS)

    Salyer, Terry

    2017-06-01

    For the bulk of detonation performance experiments, a fairly basic set of diagnostic techniques has evolved as the standard for acquiring the necessary measurements. Gold standard techniques such as pin switches and streak cameras still produce the high-quality data required, yet much room remains for improvement with regard to ease of use, cost of fielding, breadth of data, and diagnostic versatility. Over the past several years, an alternate set of diagnostics has been under development to replace many of these traditional techniques. Pulse Correlation Reflectometry (PCR) is a capable substitute for pin switches with the advantage of obtaining orders of magnitude more data at a small fraction of the cost and fielding time. Spectrally Encoded Imaging (SEI) can replace most applications of streak camera with the advantage of imaging surfaces through a single optical fiber that are otherwise optically inaccessible. Such diagnostics advance the measurement state of the art, but even further improvements may come through revamping the standardized tests themselves such as the copper cylinder expansion test. At the core of this modernization, the aforementioned diagnostics play a significant role in revamping and improving the standard test suite for the present era. This research was performed under the auspices of the United States Department of Energy.

  9. Concept of a photon-counting camera based on a diffraction-addressed Gray-code mask

    NASA Astrophysics Data System (ADS)

    Morel, Sébastien

    2004-09-01

    A new concept of photon counting camera for fast and low-light-level imaging applications is introduced. The possible spectrum covered by this camera ranges from visible light to gamma rays, depending on the device used to transform an incoming photon into a burst of visible photons (photo-event spot) localized in an (x,y) image plane. It is actually an evolution of the existing "PAPA" (Precision Analog Photon Address) Camera that was designed for visible photons. This improvement comes from a simplified optics. The new camera transforms, by diffraction, each photo-event spot from an image intensifier or a scintillator into a cross-shaped pattern, which is projected onto a specific Gray code mask. The photo-event position is then extracted from the signal given by an array of avalanche photodiodes (or photomultiplier tubes, alternatively) downstream of the mask. After a detailed explanation of this camera concept that we have called "DIAMICON" (DIffraction Addressed Mask ICONographer), we briefly discuss about technical solutions to build such a camera.

  10. Sub-picosecond streak camera measurements at LLNL: From IR to x-rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuba, J; Shepherd, R; Booth, R

    An ultra fast, sub-picosecond resolution streak camera has been recently developed at the LLNL. The camera is a versatile instrument with a wide operating wavelength range. The temporal resolution of up to 300 fs can be achieved, with routine operation at 500 fs. The streak camera has been operated in a wide wavelength range from IR to x-rays up to 2 keV. In this paper we briefly review the main design features that result in the unique properties of the streak camera and present its several scientific applications: (1) Streak camera characterization using a Michelson interferometer in visible range, (2)more » temporally resolved study of a transient x-ray laser at 14.7 nm, which enabled us to vary the x-ray laser pulse duration from {approx}2-6 ps by changing the pump laser parameters, and (3) an example of a time-resolved spectroscopy experiment with the streak camera.« less

  11. Characterizing a fast-response, low-afterglow liquid scintillator for neutron time-of-flight diagnostics in fast ignition experiments.

    PubMed

    Abe, Y; Hosoda, H; Arikawa, Y; Nagai, T; Kojima, S; Sakata, S; Inoue, H; Iwasa, Y; Iwano, K; Yamanoi, K; Fujioka, S; Nakai, M; Sarukura, N; Shiraga, H; Norimatsu, T; Azechi, H

    2014-11-01

    The characteristics of oxygen-enriched liquid scintillators with very low afterglow are investigated and optimized for application to a single-hit neutron spectrometer for fast ignition experiments. It is found that 1,2,4-trimethylbenzene has better characteristics as a liquid scintillator solvent than the conventional solvent, p-xylene. In addition, a benzophenon-doped BBQ liquid scintillator is shown to demonstrate very rapid time response, and therefore has potential for further use in neutron diagnostics with fast time resolution.

  12. Screening for phaeochromocytoma and paraganglioma: impact of using supine reference intervals for plasma metanephrines with samples collected from fasted/seated patients.

    PubMed

    Casey, R; Griffin, T P; Wall, D; Dennedy, M C; Bell, M; O'Shea, P M

    2017-01-01

    Background The Endocrine Society Clinical Practice Guideline on Phaeochomocytoma and Paraganglioma recommends phlebotomy for plasma-free metanephrines with patients fasted and supine using appropriately defined reference intervals. Studies have shown higher diagnostic sensitivities using these criteria. Further, with seated-sampling protocols, for result interpretation, reference intervals that do not compromise diagnostic sensitivity should be employed. Objective To determine the impact on diagnostic performance and financial cost of using supine reference intervals for result interpretation with our current plasma-free metanephrines fasted/seated-sampling protocol. Methods We conducted a retrospective cohort study of patients who underwent screening for PPGL using plasma-free metanephrines from 2009 to 2014 at Galway University Hospitals. Plasma-free metanephrines were measured using liquid chromatography-tandem mass spectrometry. Supine thresholds for plasma normetanephrine and metanephrine set at 610 pmol/L and 310 pmol/L, respectively, were used. Results A total of 183 patients were evaluated. Mean age of participants was 53.4 (±16.3) years. Five of 183 (2.7%) patients had histologically confirmed PPGL (males, n=4). Using seated reference intervals for plasma-free metanephrines, diagnostic sensitivity and specificity were 100% and 98.9%, respectively, with two false-positive cases. Application of reference intervals established in subjects supine and fasted to this cohort gave diagnostic sensitivity of 100% with specificity of 74.7%. Financial analysis of each pretesting strategy demonstrated cost-equivalence (€147.27/patient). Conclusion Our cost analysis, together with the evidence that fasted/supine-sampling for plasma-free metanephrines, offers more reliable exclusion of PPGL mandates changing our current practice. This study highlights the important advantages of standardized diagnostic protocols for plasma-free metanephrines to ensure the highest diagnostic accuracy for investigation of PPGL.

  13. Measuring SO2 ship emissions with an ultraviolet imaging camera

    NASA Astrophysics Data System (ADS)

    Prata, A. J.

    2014-05-01

    Over the last few years fast-sampling ultraviolet (UV) imaging cameras have been developed for use in measuring SO2 emissions from industrial sources (e.g. power plants; typical emission rates ~ 1-10 kg s-1) and natural sources (e.g. volcanoes; typical emission rates ~ 10-100 kg s-1). Generally, measurements have been made from sources rich in SO2 with high concentrations and emission rates. In this work, for the first time, a UV camera has been used to measure the much lower concentrations and emission rates of SO2 (typical emission rates ~ 0.01-0.1 kg s-1) in the plumes from moving and stationary ships. Some innovations and trade-offs have been made so that estimates of the emission rates and path concentrations can be retrieved in real time. Field experiments were conducted at Kongsfjord in Ny Ålesund, Svalbard, where SO2 emissions from cruise ships were made, and at the port of Rotterdam, Netherlands, measuring emissions from more than 10 different container and cargo ships. In all cases SO2 path concentrations could be estimated and emission rates determined by measuring ship plume speeds simultaneously using the camera, or by using surface wind speed data from an independent source. Accuracies were compromised in some cases because of the presence of particulates in some ship emissions and the restriction of single-filter UV imagery, a requirement for fast-sampling (> 10 Hz) from a single camera. Despite the ease of use and ability to determine SO2 emission rates from the UV camera system, the limitation in accuracy and precision suggest that the system may only be used under rather ideal circumstances and that currently the technology needs further development to serve as a method to monitor ship emissions for regulatory purposes. A dual-camera system or a single, dual-filter camera is required in order to properly correct for the effects of particulates in ship plumes.

  14. Fast calibration of electromagnetically tracked oblique-viewing rigid endoscopes.

    PubMed

    Liu, Xinyang; Rice, Christina E; Shekhar, Raj

    2017-10-01

    The oblique-viewing (i.e., angled) rigid endoscope is a commonly used tool in conventional endoscopic surgeries. The relative rotation between its two moveable parts, the telescope and the camera head, creates a rotation offset between the actual and the projection of an object in the camera image. A calibration method tailored to compensate such offset is needed. We developed a fast calibration method for oblique-viewing rigid endoscopes suitable for clinical use. In contrast to prior approaches based on optical tracking, we used electromagnetic (EM) tracking as the external tracking hardware to improve compactness and practicality. Two EM sensors were mounted on the telescope and the camera head, respectively, with considerations to minimize EM tracking errors. Single-image calibration was incorporated into the method, and a sterilizable plate, laser-marked with the calibration pattern, was also developed. Furthermore, we proposed a general algorithm to estimate the rotation center in the camera image. Formulas for updating the camera matrix in terms of clockwise and counterclockwise rotations were also developed. The proposed calibration method was validated using a conventional [Formula: see text], 5-mm laparoscope. Freehand calibrations were performed using the proposed method, and the calibration time averaged 2 min and 8 s. The calibration accuracy was evaluated in a simulated clinical setting with several surgical tools present in the magnetic field of EM tracking. The root-mean-square re-projection error averaged 4.9 pixel (range 2.4-8.5 pixel, with image resolution of [Formula: see text] for rotation angles ranged from [Formula: see text] to [Formula: see text]. We developed a method for fast and accurate calibration of oblique-viewing rigid endoscopes. The method was also designed to be performed in the operating room and will therefore support clinical translation of many emerging endoscopic computer-assisted surgical systems.

  15. Fast-ion D(alpha) measurements and simulations in DIII-D

    NASA Astrophysics Data System (ADS)

    Luo, Yadong

    The fast-ion Dalpha diagnostic measures the Doppler-shifted Dalpha light emitted by neutralized fast ions. For a favorable viewing geometry, the bright interferences from beam neutrals, halo neutrals, and edge neutrals span over a small wavelength range around the Dalpha rest wavelength and are blocked by a vertical bar at the exit focal plane of the spectrometer. Background subtraction and fitting techniques eliminate various contaminants in the spectrum. Fast-ion data are acquired with a time evolution of ˜1 ms, spatial resolution of ˜5 cm, and energy resolution of ˜10 keV. A weighted Monte Carlo simulation code models the fast-ion Dalpha spectra based on the fast-ion distribution function from other sources. In quiet plasmas, the spectral shape is in excellent agreement and absolute magnitude also has reasonable agreement. The fast-ion D alpha signal has the expected dependencies on plasma and neutral beam parameters. The neutral particle diagnostic and neutron diagnostic corroborate the fast-ion Dalpha measurements. The relative spatial profile is in agreement with the simulated profile based on the fast-ion distribution function from the TRANSP analysis code. During ion cyclotron heating, fast ions with high perpendicular energy are accelerated, while those with low perpendicular energy are barely affected. The spatial profile is compared with the simulated profiles based on the fast-ion distribution functions from the CQL Fokker-Planck code. In discharges with Alfven instabilities, both the spatial profile and spectral shape suggests that fast ions are redistributed. The flattened fast-ion Dalpha profile is in agreement with the fast-ion pressure profile.

  16. Three-dimensional particle tracking velocimetry using dynamic vision sensors

    NASA Astrophysics Data System (ADS)

    Borer, D.; Delbruck, T.; Rösgen, T.

    2017-12-01

    A fast-flow visualization method is presented based on tracking neutrally buoyant soap bubbles with a set of neuromorphic cameras. The "dynamic vision sensors" register only the changes in brightness with very low latency, capturing fast processes at a low data rate. The data consist of a stream of asynchronous events, each encoding the corresponding pixel position, the time instant of the event and the sign of the change in logarithmic intensity. The work uses three such synchronized cameras to perform 3D particle tracking in a medium sized wind tunnel. The data analysis relies on Kalman filters to associate the asynchronous events with individual tracers and to reconstruct the three-dimensional path and velocity based on calibrated sensor information.

  17. FAST CHOPPER BUILDING, TRA665. DETAIL SHOWS UPPER AND LOWER LEVEL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FAST CHOPPER BUILDING, TRA-665. DETAIL SHOWS UPPER AND LOWER LEVEL WALLS OF DIFFERING MATERIALS. NOTE DOORWAY TO MTR TO RIGHT OF CHOPPER BUILDING'S CLIPPED CORNER. CAMERA FACING WEST. INL NEGATIVE NO. HD42-1. Mike Crane, Photographer, 3/2004 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  18. Electron density in surface barrier discharge emerging at argon/water interface: quantification for streamers and leaders

    NASA Astrophysics Data System (ADS)

    Cvetanović, Nikola; Galmiz, Oleksandr; Synek, Petr; Zemánek, Miroslav; Brablec, Antonín; Hoder, Tomáš

    2018-02-01

    Optical emission spectroscopy, fast intensified CCD imaging and electrical measurements were applied to investigate the basic plasma parameters of surface barrier discharge emerging from a conductive water electrode. The discharge was generated at the triple-line interface of atmospheric pressure argon gas and conductive water solution at the fused silica dielectrics using a sinusoidal high-voltage waveform. The spectroscopic methods of atomic line broadening and molecular spectroscopy were used to determine the electron densities and the gas temperature in the active plasma. These parameters were obtained for both applied voltage polarities and resolved spatially. Two different spectral signatures were identified in the spatially resolved spectra resulting in electron densities differing by two orders of magnitude. It is shown that two discharge mechanisms take a place: the streamer and the leader one, with electron densities of 1014 and 1016 cm-3, respectively. This spectroscopic evidence is supported by the combined diagnostics of electrical current measurements and phase-resolved intensified CCD camera imaging.

  19. Injection of a coaxial-gun-produced magnetized plasma into a background helicon plasma

    NASA Astrophysics Data System (ADS)

    Zhang, Yue; Lynn, Alan; Gilmore, Mark; Hsu, Scott

    2014-10-01

    A compact coaxial plasma gun is employed for experimental investigation of plasma bubble relaxation into a lower density background plasma. Experiments are being conducted in the linear device HelCat at UNM. The gun is powered by a 120-uF ignitron-switched capacitor bank, which is operated in a range of 5 to 10 kV and 100 kA. Multiple diagnostics are employed to investigate the plasma relaxation process. Magnetized argon plasma bubbles with velocities 1.2Cs, densities 1020 m-3 and electron temperature 13eV have been achieved. The background helicon plasma has density 1013 m-3, magnetic field from 200 to 500 Gauss and electron temperature 1eV. Several distinct operational regimes with qualitatively different dynamics are identified by fast CCD camera images. Additionally a B-dot probe array has been employed to measure the spatial toroidal and poloidal magnetic flux evolution to identify plasma bubble configurations. Experimental data and analysis will be presented.

  20. High-voltage subnanosecond dielectric breakdown

    NASA Astrophysics Data System (ADS)

    Mankowski, John Jerome

    Current interests in ultrawideband radar sources are in the microwave regime, which correspond to voltage pulse risetimes less than a nanosecond. Some new sources, including the Phillips Laboratory Hindenberg series of hydrogen gas switched pulsers use hydrogen at hundreds of atmospheres of pressure in the switch. Unfortunately, the published data of electrical breakdown of gas and liquid media at these time lengths are relatively scarce. A study was conducted on the electrical breakdown properties of liquid and gas dielectrics at subnanosecond and nanoseconds. Two separate voltage sources with pulse risetimes less than 400 ps were developed. Diagnostic probes were designed and tested for their capability of detecting high voltage pulses at these fast risetimes. A thorough investigation into E-field strengths of liquid and gas dielectrics at breakdown times ranging from 0.4 to 5 ns was performed. The voltage polarity dependence on breakdown strength is observed. Streak camera images of streamer formation were taken. The effect of ultraviolet radiation, incident upon the gap, on statistical lag time was determined.

  1. Spectroscopic imaging using acousto-optic tunable filters

    NASA Astrophysics Data System (ADS)

    Bouhifd, Mounir; Whelan, Maurice

    2007-07-01

    We report on novel hyper-spectral imaging filter-modules based on acousto-optic tuneable filters (AOTF). The AOTF functions as a full-field tuneable bandpass filter which offers fast continuous or random access tuning with high filtering efficiency. Due to the diffractive nature of the device, the unfiltered zero-order and the filtered first-order images are geometrically separated. The modules developed exploit this feature to simultaneously route both the transmitted white-light image and the filtered fluorescence image to two separate cameras. Incorporation of prisms in the optical paths and careful design of the relay optics in the filter module have overcome a number of aberrations inherent to imaging through AOTFs, leading to excellent spatial resolution. A number of practical uses of this technique, both for in vivo auto-fluorescence endoscopy and in vitro fluorescence microscopy were demonstrated. We describe the operational principle and design of recently improved prototype instruments for fluorescence-based diagnostics and demonstrate their performance by presenting challenging hyper-spectral fluorescence imaging applications.

  2. In Situ Optical Mapping of Voltage and Calcium in the Heart

    PubMed Central

    Ewart, Paul; Ashley, Euan A.; Loew, Leslie M.; Kohl, Peter; Bollensdorff, Christian; Woods, Christopher E.

    2012-01-01

    Electroanatomic mapping the interrelation of intracardiac electrical activation with anatomic locations has become an important tool for clinical assessment of complex arrhythmias. Optical mapping of cardiac electrophysiology combines high spatiotemporal resolution of anatomy and physiological function with fast and simultaneous data acquisition. If applied to the clinical setting, this could improve both diagnostic potential and therapeutic efficacy of clinical arrhythmia interventions. The aim of this study was to explore this utility in vivo using a rat model. To this aim, we present a single-camera imaging and multiple light-emitting-diode illumination system that reduces economic and technical implementation hurdles to cardiac optical mapping. Combined with a red-shifted calcium dye and a new near-infrared voltage-sensitive dye, both suitable for use in blood-perfused tissue, we demonstrate the feasibility of in vivo multi-parametric imaging of the mammalian heart. Our approach combines recording of electrophysiologically-relevant parameters with observation of structural substrates and is adaptable, in principle, to trans-catheter percutaneous approaches. PMID:22876327

  3. Photogrammetry research for FAST eleven-meter reflector panel surface shape measurement

    NASA Astrophysics Data System (ADS)

    Zhou, Rongwei; Zhu, Lichun; Li, Weimin; Hu, Jingwen; Zhai, Xuebing

    2010-10-01

    In order to design and manufacture the Five-hundred-meter Aperture Spherical Radio Telescope (FAST) active reflector measuring equipment, measurement on each reflector panel surface shape was presented, static measurement of the whole neutral spherical network of nodes was performed, real-time dynamic measurement at the cable network dynamic deformation was undertaken. In the implementation process of the FAST, reflector panel surface shape detection was completed before eleven-meter reflector panel installation. Binocular vision system was constructed based on the method of binocular stereo vision in machine vision, eleven-meter reflector panel surface shape was measured with photogrammetry method. Cameras were calibrated with the feature points. Under the linearity camera model, the lighting spot array was used as calibration standard pattern, and the intrinsic and extrinsic parameters were acquired. The images were collected for digital image processing and analyzing with two cameras, feature points were extracted with the detection algorithm of characteristic points, and those characteristic points were matched based on epipolar constraint method. Three-dimensional reconstruction coordinates of feature points were analyzed and reflective panel surface shape structure was established by curve and surface fitting method. The error of reflector panel surface shape was calculated to realize automatic measurement on reflector panel surface shape. The results show that unit reflector panel surface inspection accuracy was 2.30mm, within the standard deviation error of 5.00mm. Compared with the requirement of reflector panel machining precision, photogrammetry has fine precision and operation feasibility on eleven-meter reflector panel surface shape measurement for FAST.

  4. Observation of runaway electrons by infrared camera in J-TEXT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tong, R. H.; Chen, Z. Y., E-mail: zychen@hust.edu.cn; Zhang, M.

    2016-11-15

    When the energy of confined runaway electrons approaches several tens of MeV, the runaway electrons can emit synchrotron radiation in the range of infrared wavelength. An infrared camera working in the wavelength of 3-5 μm has been developed to study the runaway electrons in the Joint Texas Experimental Tokamak (J-TEXT). The camera is located in the equatorial plane looking tangentially into the direction of electron approach. The runaway electron beam inside the plasma has been observed at the flattop phase. With a fast acquisition of the camera, the behavior of runaway electron beam has been observed directly during the runawaymore » current plateau following the massive gas injection triggered disruptions.« less

  5. Camera calibration for multidirectional flame chemiluminescence tomography

    NASA Astrophysics Data System (ADS)

    Wang, Jia; Zhang, Weiguang; Zhang, Yuhong; Yu, Xun

    2017-04-01

    Flame chemiluminescence tomography (FCT), which combines computerized tomography theory and multidirectional chemiluminescence emission measurements, can realize instantaneous three-dimensional (3-D) diagnostics for flames with high spatial and temporal resolutions. One critical step of FCT is to record the projections by multiple cameras from different view angles. For high accuracy reconstructions, it requires that extrinsic parameters (the positions and orientations) and intrinsic parameters (especially the image distances) of cameras be accurately calibrated first. Taking the focus effect of the camera into account, a modified camera calibration method was presented for FCT, and a 3-D calibration pattern was designed to solve the parameters. The precision of the method was evaluated by reprojections of feature points to cameras with the calibration results. The maximum root mean square error of the feature points' position is 1.42 pixels and 0.0064 mm for the image distance. An FCT system with 12 cameras was calibrated by the proposed method and the 3-D CH* intensity of a propane flame was measured. The results showed that the FCT system provides reasonable reconstruction accuracy using the camera's calibration results.

  6. Versatile illumination platform and fast optical switch to give standard observation camera gated active imaging capacity

    NASA Astrophysics Data System (ADS)

    Grasser, R.; Peyronneaudi, Benjamin; Yon, Kevin; Aubry, Marie

    2015-10-01

    CILAS, subsidiary of Airbus Defense and Space, develops, manufactures and sales laser-based optronics equipment for defense and homeland security applications. Part of its activity is related to active systems for threat detection, recognition and identification. Active surveillance and active imaging systems are often required to achieve identification capacity in case for long range observation in adverse conditions. In order to ease the deployment of active imaging systems often complex and expensive, CILAS suggests a new concept. It consists on the association of two apparatus working together. On one side, a patented versatile laser platform enables high peak power laser illumination for long range observation. On the other side, a small camera add-on works as a fast optical switch to select photons with specific time of flight only. The association of the versatile illumination platform and the fast optical switch presents itself as an independent body, so called "flash module", giving to virtually any passive observation systems gated active imaging capacity in NIR and SWIR.

  7. Tomography of the fast electron bremsstrahlung emission during lower hybrid current drive on TORE SUPRA

    NASA Astrophysics Data System (ADS)

    Peysson, Yves; Imbeaux, Frédéric

    1999-10-01

    A new tomography dedicated to detailed studies of the fast electron bremsstrahlung emission in the hard x-ray (HXR) energy range between 20 and 200 keV during lower hybrid (LH) current drive experiments on the TORE SUPRA tokamak [Equipe TORE SUPRA, in Proceedings of the 15th Conference on Plasma Physics and Controlled Nuclear Fusion Research, Seville (International Atomic Energy Agency, Vienna, 1995), Vol. 1, AIEA-CN-60 / A1-5, p. 105] is presented. Radiation detection is performed by cadmium telluride semiconductors, which have most of the desirable features for a powerful diagnosing of magnetically confined hot plasmas—compact size, high x-ray stopping efficiency, fast timing characteristics, good energy resolution, no sensitivity to magnetic field, reasonable susceptibility to performance degradation from neutron/γ-induced damages. This instrument is made of two independent cameras viewing a poloidal cross-section of the plasma, with respectively 21 and 38 detectors. A coarse spectrometry—8 energy channels—is carried out for each chord, with an energy resolution of 20 keV. The spatial resolution in the core of the plasma is 4-5 cm, while the time sampling may be lowered down to of 2-4 ms. Powerful inversion techniques based on maximum entropy or regularization algorithms take full advantage of the large number of line-integrated measurements for very robust estimates of the local HXR profiles as a function of time and photon energy. A detailed account of main characteristics and performances of the diagnostic is reported, as well as preliminary results on LH current drive experiments.

  8. Investigation of high power impulse magnetron sputtering (HIPIMS) discharge using fast ICCD camera

    NASA Astrophysics Data System (ADS)

    Hecimovic, Ante

    2012-10-01

    High power impulse magnetron sputtering (HIPIMS) combines impulse glow discharges at power levels up to the MW range with conventional magnetron cathodes to achieve a highly ionised sputtered flux. The dynamics of the HIPIMS discharge was investigated using fast Intensified Charge Coupled Device (ICCD) camera. In the first experiment the HIPIMS plasma was recorded from the side with goal to analyse the plasma intensity using Abel inversion to obtain the emissivity maps of the plasma species. Resulting emissivity maps provide the information on the spatial distribution of Ar and sputtered material and evolution of the plasma chemistry above the cathode. In the second experiment the plasma emission was recorded with camera facing the target. The images show that the HIPIMS plasma develops drift wave type instabilities characterized by well defined regions of high and low plasma emissivity along the racetrack of the magnetron. The instabilities cause periodic shifts in the floating potential. The structures rotate in ExB direction at velocities of 10 kms-1 and frequencies up to 200 kHz. The high emissivity regions comprise Ar and metal ion emission with strong Ar and metal neutral emission depletion. A detailed analysis of the temporal evolution of the saturated instabilities using four consequently triggered fast ICCD cameras is presented. Furthermore working gas pressure and discharge current variation showed that the shape and the speed of the instability strongly depend on the working gas and target material combination. In order to better understand the mechanism of the instability, different optical interference band pass filters (of metal and gas atom, and ion lines) were used to observe the spatial distribution of each species within the instability.

  9. Performance of Laser Megajoule’s x-ray streak camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zuber, C., E-mail: celine.zuber@cea.fr; Bazzoli, S.; Brunel, P.

    2016-11-15

    A prototype of a picosecond x-ray streak camera has been developed and tested by Commissariat à l’Énergie Atomique et aux Énergies Alternatives to provide plasma-diagnostic support for the Laser Megajoule. We report on the measured performance of this streak camera, which almost fulfills the requirements: 50-μm spatial resolution over a 15-mm field in the photocathode plane, 17-ps temporal resolution in a 2-ns timebase, a detection threshold lower than 625 nJ/cm{sup 2} in the 0.05–15 keV spectral range, and a dynamic range greater than 100.

  10. Mid infra-red hyper-spectral imaging with bright super continuum source and fast acousto-optic tuneable filter for cytological applications.

    NASA Astrophysics Data System (ADS)

    Farries, Mark; Ward, Jon; Valle, Stefano; Stephens, Gary; Moselund, Peter; van der Zanden, Koen; Napier, Bruce

    2015-06-01

    Mid-IR imaging spectroscopy has the potential to offer an effective tool for early cancer diagnosis. Current development of bright super-continuum sources, narrow band acousto-optic tunable filters and fast cameras have made feasible a system that can be used for fast diagnosis of cancer in vivo at point of care. The performance of a proto system that has been developed under the Minerva project is described.

  11. Design of the high-resolution soft X-ray imaging system on the Joint Texas Experimental Tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Jianchao; Ding, Yonghua, E-mail: yhding@mail.hust.edu.cn; Zhang, Xiaoqing

    2014-11-15

    A new soft X-ray diagnostic system has been designed on the Joint Texas Experimental Tokamak (J-TEXT) aiming to observe and survey the magnetohydrodynamic (MHD) activities. The system consists of five cameras located at the same toroidal position. Each camera has 16 photodiode elements. Three imaging cameras view the internal plasma region (r/a < 0.7) with a spatial resolution about 2 cm. By tomographic method, heat transport outside from the 1/1 mode X-point during the sawtooth collapse is found. The other two cameras with a higher spatial resolution 1 cm are designed for monitoring local MHD activities respectively in plasma coremore » and boundary.« less

  12. Distributed Sensing and Processing for Multi-Camera Networks

    NASA Astrophysics Data System (ADS)

    Sankaranarayanan, Aswin C.; Chellappa, Rama; Baraniuk, Richard G.

    Sensor networks with large numbers of cameras are becoming increasingly prevalent in a wide range of applications, including video conferencing, motion capture, surveillance, and clinical diagnostics. In this chapter, we identify some of the fundamental challenges in designing such systems: robust statistical inference, computationally efficiency, and opportunistic and parsimonious sensing. We show that the geometric constraints induced by the imaging process are extremely useful for identifying and designing optimal estimators for object detection and tracking tasks. We also derive pipelined and parallelized implementations of popular tools used for statistical inference in non-linear systems, of which multi-camera systems are examples. Finally, we highlight the use of the emerging theory of compressive sensing in reducing the amount of data sensed and communicated by a camera network.

  13. Enceladus Up-Close

    NASA Image and Video Library

    2015-10-30

    During its closest ever dive past the active south polar region of Saturn moon Enceladus, NASA Cassini spacecraft quickly shuttered its imaging cameras to capture glimpses of the fast moving terrain below.

  14. Camera Concepts for the Advanced Gamma-Ray Imaging System (AGIS)

    NASA Astrophysics Data System (ADS)

    Nepomuk Otte, Adam

    2009-05-01

    The Advanced Gamma-Ray Imaging System (AGIS) is a concept for the next generation observatory in ground-based very high energy gamma-ray astronomy. Design goals are ten times better sensitivity, higher angular resolution, and a lower energy threshold than existing Cherenkov telescopes. Each telescope is equipped with a camera that detects and records the Cherenkov-light flashes from air showers. The camera is comprised of a pixelated focal plane of blue sensitive and fast (nanosecond) photon detectors that detect the photon signal and convert it into an electrical one. The incorporation of trigger electronics and signal digitization into the camera are under study. Given the size of AGIS, the camera must be reliable, robust, and cost effective. We are investigating several directions that include innovative technologies such as Geiger-mode avalanche-photodiodes as a possible detector and switched capacitor arrays for the digitization.

  15. Invited Article: Quantitative imaging of explosions with high-speed cameras

    DOE PAGES

    McNesby, Kevin L.; Homan, Barrie E.; Benjamin, Richard A.; ...

    2016-05-31

    Here, the techniques presented in this paper allow for mapping of temperature, pressure, chemical species, and energy deposition during and following detonations of explosives, using high speed cameras as the main diagnostic tool. Additionally, this work provides measurement in the explosive near to far-field (0-500 charge diameters) of surface temperatures, peak air-shock pressures, some chemical species signatures, shock energy deposition, and air shock formation.

  16. X-ray pinhole camera setups used in the Atomki ECR Laboratory for plasma diagnostics.

    PubMed

    Rácz, R; Biri, S; Pálinkás, J; Mascali, D; Castro, G; Caliri, C; Romano, F P; Gammino, S

    2016-02-01

    Imaging of the electron cyclotron resonance (ECR) plasmas by using CCD camera in combination with a pinhole is a non-destructive diagnostics method to record the strongly inhomogeneous spatial density distribution of the X-ray emitted by the plasma and by the chamber walls. This method can provide information on the location of the collisions between warm electrons and multiple charged ions/atoms, opening the possibility to investigate the direct effect of the ion source tuning parameters to the plasma structure. The first successful experiment with a pinhole X-ray camera was carried out in the Atomki ECR Laboratory more than 10 years ago. The goal of that experiment was to make the first ECR X-ray photos and to carry out simple studies on the effect of some setting parameters (magnetic field, extraction, disc voltage, gas mixing, etc.). Recently, intensive efforts were taken to investigate now the effect of different RF resonant modes to the plasma structure. Comparing to the 2002 experiment, this campaign used wider instrumental stock: CCD camera with a lead pinhole was placed at the injection side allowing X-ray imaging and beam extraction simultaneously. Additionally, Silicon Drift Detector (SDD) and High Purity Germanium (HPGe) detectors were installed to characterize the volumetric X-ray emission rate caused by the warm and hot electron domains. In this paper, detailed comparison study on the two X-ray camera and detector setups and also on the technical and scientific goals of the experiments is presented.

  17. Near-infrared transillumination photography of intraocular tumours.

    PubMed

    Krohn, Jørgen; Ulltang, Erlend; Kjersem, Bård

    2013-10-01

    To present a technique for near-infrared transillumination imaging of intraocular tumours based on the modifications of a conventional digital slit lamp camera system. The Haag-Streit Photo-Slit Lamp BX 900 (Haag-Streit AG) was used for transillumination photography by gently pressing the tip of the background illumination cable against the surface of the patient's eye. Thus the light from the flash unit was transmitted into the eye, leading to improved illumination and image resolution. The modification for near-infrared photography was done by replacing the original camera with a Canon EOS 30D (Canon Inc) converted by Advanced Camera Services Ltd. In this camera, the infrared blocking filter was exchanged for a 720 nm long-pass filter, so that the near-infrared part of the spectrum was recorded by the sensor. The technique was applied in eight patients: three with anterior choroidal melanoma, three with ciliary body melanoma and two with ocular pigment alterations. The good diagnostic quality of the photographs made it possible to evaluate the exact location and extent of the lesions in relation to pigmented intraocular landmarks such as the ora serrata and ciliary body. The photographic procedure did not lead to any complications. We recommend near-infrared transillumination photography as a supplementary diagnostic tool for the evaluation and documentation of anteriorly located intraocular tumours.

  18. On a gas electron multiplier based synthetic diagnostic for soft x-ray tomography on WEST with focus on impurity transport studies

    NASA Astrophysics Data System (ADS)

    Jardin, A.; Mazon, D.; Malard, P.; O'Mullane, M.; Chernyshova, M.; Czarski, T.; Malinowski, K.; Kasprowicz, G.; Wojenski, A.; Pozniak, K.

    2017-08-01

    The tokamak WEST aims at testing ITER divertor high heat flux component technology in long pulse operation. Unfortunately, heavy impurities like tungsten (W) sputtered from the plasma facing components can pollute the plasma core by radiation cooling in the soft x-ray (SXR) range, which is detrimental for the energy confinement and plasma stability. SXR diagnostics give valuable information to monitor impurities and study their transport. The WEST SXR diagnostic is composed of two new cameras based on the Gas Electron Multiplier (GEM) technology. The WEST GEM cameras will be used for impurity transport studies by performing 2D tomographic reconstructions with spectral resolution in tunable energy bands. In this paper, we characterize the GEM spectral response and investigate W density reconstruction thanks to a synthetic diagnostic recently developed and coupled with a tomography algorithm based on the minimum Fisher information (MFI) inversion method. The synthetic diagnostic includes the SXR source from a given plasma scenario, the photoionization, electron cloud transport and avalanche in the detection volume using Magboltz, and tomographic reconstruction of the radiation from the GEM signal. Preliminary studies of the effect of transport on the W ionization equilibrium and on the reconstruction capabilities are also presented.

  19. A fluctuation-induced plasma transport diagnostic based upon fast-Fourier transform spectral analysis

    NASA Technical Reports Server (NTRS)

    Powers, E. J.; Kim, Y. C.; Hong, J. Y.; Roth, J. R.; Krawczonek, W. M.

    1978-01-01

    A diagnostic, based on fast Fourier-transform spectral analysis techniques, that provides experimental insight into the relationship between the experimentally observable spectral characteristics of the fluctuations and the fluctuation-induced plasma transport is described. The model upon which the diagnostic technique is based and its experimental implementation is discussed. Some characteristic results obtained during the course of an experimental study of fluctuation-induced transport in the electric field dominated NASA Lewis bumpy torus plasma are presented.

  20. Implementing large scale fast track diagnostics in a comprehensive cancer center, pre- and post-measurement data.

    PubMed

    van Harten, W H; Goedbloed, N; Boekhout, A H; Heintzbergen, S

    2018-02-07

    In general, patients with a cancer suspicion visit the hospital multiple times before diagnosis is completed. Using various "operations management" techniques a few fast track diagnostic services were implemented in the Netherlands Cancer Institute (NKI) in 2006. Growing patient numbers and increasing process complexity, led to diminished service levels. To decrease the amount of patient visits and to extend these services beyond the (obvious) breast cancer services, fast track diagnostics is now implemented for all 18 cancer types that present with a frequency of minimally one per week. The throughput time (first visit to diagnosis conversation) was measured before, and after implementation of fast track diagnostics. The process was redesigned closely involving the multidisciplinary teams. In an eclectic approach elements from lean management, theory of constraints and mathematical analysis were used to organize slots per tumor type for MRI, CT, PET and echography. A post measurement was performed after 3 and 6 months. In pre measurement access time was calculated to be 10 to 15 workdays, mean throughput time was 6.0 workdays. It proved possible to design the process of 18 tumors as a fast track, of which 7 as "one stop shop" (diagnosis completed in one visit). Involvement of clinical- and board leadership, massive communication efforts and commitment of physicians to reschedule their work proved decisive. After 3 and 6 months of implementation, the mean access time was 8.2 and 8.7 workdays respectively and mean throughput time was 3.4 and 3.3 workdays respectively. Throughput- and access time were considerably shortened after implementation of fast track diagnostics for 18 cancer types. The involvement of physicians in reorganizing their work and rapid responding to their needs during the implementation phase were a crucial success factor.

  1. Simultaneous planar measurements of soot structure and velocity fields in a turbulent lifted jet flame at 3 kHz

    NASA Astrophysics Data System (ADS)

    Köhler, M.; Boxx, I.; Geigle, K. P.; Meier, W.

    2011-05-01

    We describe a newly developed combustion diagnostic for the simultaneous planar imaging of soot structure and velocity fields in a highly sooting, lifted turbulent jet flame at 3000 frames per second, or two orders of magnitude faster than "conventional" laser imaging systems. This diagnostic uses short pulse duration (8 ns), frequency-doubled, diode-pumped solid state (DPSS) lasers to excite laser-induced incandescence (LII) at 3 kHz, which is then imaged onto a high framerate CMOS camera. A second (dual-cavity) DPSS laser and CMOS camera form the basis of a particle image velocity (PIV) system used to acquire 2-component velocity field in the flame. The LII response curve (measured in a laminar propane diffusion flame) is presented and the combined diagnostics then applied in a heavily sooting lifted turbulent jet flame. The potential challenges and rewards of application of this combined imaging technique at high speeds are discussed.

  2. Reading Out Single-Molecule Digital RNA and DNA Isothermal Amplification in Nanoliter Volumes with Unmodified Camera Phones

    PubMed Central

    2016-01-01

    Digital single-molecule technologies are expanding diagnostic capabilities, enabling the ultrasensitive quantification of targets, such as viral load in HIV and hepatitis C infections, by directly counting single molecules. Replacing fluorescent readout with a robust visual readout that can be captured by any unmodified cell phone camera will facilitate the global distribution of diagnostic tests, including in limited-resource settings where the need is greatest. This paper describes a methodology for developing a visual readout system for digital single-molecule amplification of RNA and DNA by (i) selecting colorimetric amplification-indicator dyes that are compatible with the spectral sensitivity of standard mobile phones, and (ii) identifying an optimal ratiometric image-process for a selected dye to achieve a readout that is robust to lighting conditions and camera hardware and provides unambiguous quantitative results, even for colorblind users. We also include an analysis of the limitations of this methodology, and provide a microfluidic approach that can be applied to expand dynamic range and improve reaction performance, allowing ultrasensitive, quantitative measurements at volumes as low as 5 nL. We validate this methodology using SlipChip-based digital single-molecule isothermal amplification with λDNA as a model and hepatitis C viral RNA as a clinically relevant target. The innovative combination of isothermal amplification chemistry in the presence of a judiciously chosen indicator dye and ratiometric image processing with SlipChip technology allowed the sequence-specific visual readout of single nucleic acid molecules in nanoliter volumes with an unmodified cell phone camera. When paired with devices that integrate sample preparation and nucleic acid amplification, this hardware-agnostic approach will increase the affordability and the distribution of quantitative diagnostic and environmental tests. PMID:26900709

  3. HIGH SPEED CAMERA

    DOEpatents

    Rogers, B.T. Jr.; Davis, W.C.

    1957-12-17

    This patent relates to high speed cameras having resolution times of less than one-tenth microseconds suitable for filming distinct sequences of a very fast event such as an explosion. This camera consists of a rotating mirror with reflecting surfaces on both sides, a narrow mirror acting as a slit in a focal plane shutter, various other mirror and lens systems as well as an innage recording surface. The combination of the rotating mirrors and the slit mirror causes discrete, narrow, separate pictures to fall upon the film plane, thereby forming a moving image increment of the photographed event. Placing a reflecting surface on each side of the rotating mirror cancels the image velocity that one side of the rotating mirror would impart, so as a camera having this short a resolution time is thereby possible.

  4. Solid state television camera (CCD-buried channel)

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The development of an all solid state television camera, which uses a buried channel charge coupled device (CCD) as the image sensor, was undertaken. A 380 x 488 element CCD array is utilized to ensure compatibility with 525 line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (a) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (b) techniques for the elimination or suppression of CCD blemish effects, and (c) automatic light control and video gain control (i.e., ALC and AGC) techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a deliverable solid state TV camera which addressed the program requirements for a prototype qualifiable to space environment conditions.

  5. Solid state television camera (CCD-buried channel), revision 1

    NASA Technical Reports Server (NTRS)

    1977-01-01

    An all solid state television camera was designed which uses a buried channel charge coupled device (CCD) as the image sensor. A 380 x 488 element CCD array is utilized to ensure compatibility with 525-line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (1) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (2) techniques for the elimination or suppression of CCD blemish effects, and (3) automatic light control and video gain control techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a deliverable solid state TV camera which addressed the program requirements for a prototype qualifiable to space environment conditions.

  6. Experiments with synchronized sCMOS cameras

    NASA Astrophysics Data System (ADS)

    Steele, Iain A.; Jermak, Helen; Copperwheat, Chris M.; Smith, Robert J.; Poshyachinda, Saran; Soonthorntham, Boonrucksar

    2016-07-01

    Scientific-CMOS (sCMOS) cameras can combine low noise with high readout speeds and do not suffer the charge multiplication noise that effectively reduces the quantum efficiency of electron multiplying CCDs by a factor 2. As such they have strong potential in fast photometry and polarimetry instrumentation. In this paper we describe the results of laboratory experiments using a pair of commercial off the shelf sCMOS cameras based around a 4 transistor per pixel architecture. In particular using a both stable and a pulsed light sources we evaluate the timing precision that may be obtained when the cameras readouts are synchronized either in software or electronically. We find that software synchronization can introduce an error of 200-msec. With electronic synchronization any error is below the limit ( 50-msec) of our simple measurement technique.

  7. Solid state, CCD-buried channel, television camera study and design

    NASA Technical Reports Server (NTRS)

    Hoagland, K. A.; Balopole, H.

    1976-01-01

    An investigation of an all solid state television camera design, which uses a buried channel charge-coupled device (CCD) as the image sensor, was undertaken. A 380 x 488 element CCD array was utilized to ensure compatibility with 525 line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (a) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (b) techniques for the elimination or suppression of CCD blemish effects, and (c) automatic light control and video gain control techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a design which addresses the program requirements for a deliverable solid state TV camera.

  8. Characterization of a thinned back illuminated MIMOSA V sensor as a visible light camera

    NASA Astrophysics Data System (ADS)

    Bulgheroni, Antonio; Bianda, Michele; Caccia, Massimo; Cappellini, Chiara; Mozzanica, Aldo; Ramelli, Renzo; Risigo, Fabio

    2006-09-01

    This paper reports the measurements that have been performed both in the Silicon Detector Laboratory at the University of Insubria (Como, Italy) and at the Instituto Ricerche SOlari Locarno (IRSOL) to characterize a CMOS pixel particle detector as a visible light camera. The CMOS sensor has been studied in terms of Quantum Efficiency in the visible spectrum, image blooming and reset inefficiency in saturation condition. The main goal of these measurements is to prove that this kind of particle detector can also be used as an ultra fast, 100% fill factor visible light camera in solar physics experiments.

  9. Stress myocardial perfusion imaging in the emergency department--new techniques for speed and diagnostic accuracy.

    PubMed

    Harrison, Sheri D; Harrison, Mark A; Duvall, W Lane

    2012-05-01

    Emergency room evaluations of patients presenting with chest pain continue to rise, and these evaluations which often include cardiac imaging, are an increasing area of resource utilization in the current health system. Myocardial perfusion imaging from the emergency department remains a vital component of the diagnosis or exclusion of coronary artery disease as the etiology of chest pain. Recent advances in camera technology, and changes to the imaging protocols have allowed MPI to become a more efficient way of providing this diagnostic information. Compared with conventional SPECT, new high-efficiency CZT cameras provide a 3-5 fold increase in photon sensitivity, 1.65-fold improvement in energy resolution and a 1.7-2.5-fold increase in spatial resolution. With stress-only imaging, rest images are eliminated if stress images are normal, as they provide no additional prognostic or diagnostic value and cancelling the rest images would shorten the length of the test which is of particular importance to the ED population. The rapid but accurate triage of patients in an ED CPU is essential to their care, and stress-only imaging and new CZT cameras allow for shorter test time, lower radiation doses and lower costs while demonstrating good clinical outcomes. These changes to nuclear stress testing can allow for faster throughput of patients through the emergency department while providing a safe and efficient evaluation of chest pain.

  10. Value of automatic patient motion detection and correction in myocardial perfusion imaging using a CZT-based SPECT camera.

    PubMed

    van Dijk, Joris D; van Dalen, Jorn A; Mouden, Mohamed; Ottervanger, Jan Paul; Knollema, Siert; Slump, Cornelis H; Jager, Pieter L

    2018-04-01

    Correction of motion has become feasible on cadmium-zinc-telluride (CZT)-based SPECT cameras during myocardial perfusion imaging (MPI). Our aim was to quantify the motion and to determine the value of automatic correction using commercially available software. We retrospectively included 83 consecutive patients who underwent stress-rest MPI CZT-SPECT and invasive fractional flow reserve (FFR) measurement. Eight-minute stress acquisitions were reformatted into 1.0- and 20-second bins to detect respiratory motion (RM) and patient motion (PM), respectively. RM and PM were quantified and scans were automatically corrected. Total perfusion deficit (TPD) and SPECT interpretation-normal, equivocal, or abnormal-were compared between the noncorrected and corrected scans. Scans with a changed SPECT interpretation were compared with FFR, the reference standard. Average RM was 2.5 ± 0.4 mm and maximal PM was 4.5 ± 1.3 mm. RM correction influenced the diagnostic outcomes in two patients based on TPD changes ≥7% and in nine patients based on changed visual interpretation. In only four of these patients, the changed SPECT interpretation corresponded with FFR measurements. Correction for PM did not influence the diagnostic outcomes. Respiratory motion and patient motion were small. Motion correction did not appear to improve the diagnostic outcome and, hence, the added value seems limited in MPI using CZT-based SPECT cameras.

  11. Evaluation of the irising effect of a slow-gating intensified charge-coupled device on laser-induced incandescence measurements of soot

    NASA Astrophysics Data System (ADS)

    Shaddix, Christopher R.; Williams, Timothy C.

    2009-03-01

    Intensified charge-coupled devices (ICCDs) are used extensively in many scientific and engineering environments to image weak or temporally short optical events. To optimize the quantum efficiency of light collection, many of these devices are chosen to have characteristic intensifier gate times that are relatively slow, on the order of tens of nanoseconds. For many measurements associated with nanosecond laser sources, such as scattering-based diagnostics and most laser-induced fluorescence applications, the signals rise and decay sufficiently fast during and after the laser pulse that the intensifier gate may be set to close after the cessation of the signal and still effectively reject interferences associated with longer time scales. However, the relatively long time scale and complex temporal response of laser-induced incandescence (LII) of nanometer-sized particles (such as soot) offer a difficult challenge to the use of slow-gating ICCDs for quantitative measurements. In this paper, ultraviolet Rayleigh scattering imaging is used to quantify the irising effect of a slow-gating scientific ICCD camera, and an analysis is conducted of LII image data collected with this camera as a function of intensifier gate width. The results demonstrate that relatively prompt LII detection, generally desirable to minimize the influences of particle size and local gas pressure and temperature on measurements of the soot volume fraction, is strongly influenced by the irising effect of slow-gating ICCDs.

  12. Hydrodynamics simulations of 2{omega} laser propagation in underdense gasbag plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meezan, N.B.; Divol, L.; Marinak, M.M.

    2004-12-01

    Recent 2{omega} laser propagation and stimulated Raman backscatter (SRS) experiments performed on the Helen laser have been analyzed using the radiation-hydrodynamics code HYDRA [M. M. Marinak, G. D. Kerbel, N. A. Gentile, O. Jones, D. Munro, S. Pollaine, T. R. Dittrich, and S. W. Haan, Phys. Plasmas 8, 2275 (2001)]. These experiments utilized two diagnostics sensitive to the hydrodynamics of gasbag targets: a fast x-ray framing camera (FXI) and a SRS streak spectrometer. With a newly implemented nonlocal thermal transport model, HYDRA is able to reproduce many features seen in the FXI images and the SRS streak spectra. Experimental andmore » simulated side-on FXI images suggest that propagation can be explained by classical laser absorption and the resulting hydrodynamics. Synthetic SRS spectra generated from the HYDRA results reproduce the details of the experimental SRS streak spectra. Most features in the synthetic spectra can be explained solely by axial density and temperature gradients. The total SRS backscatter increases with initial gasbag fill density up to {approx_equal}0.08 times the critical density, then decreases. Data from a near-backscatter imaging camera show that severe beam spray is not responsible for the trend in total backscatter. Filamentation does not appear to be a significant factor in gasbag hydrodynamics. The simulation and analysis techniques established here can be used in ongoing experimental campaigns on the Omega laser facility and the National Ignition Facility.« less

  13. Plasma studies of a linear magnetron operating in the range from DC to HiPIMS

    NASA Astrophysics Data System (ADS)

    Anders, André; Yang, Yuchen

    2018-01-01

    Plasma properties of magnetrons have been extensively studied in the past with the focus on small, research-style magnetrons with planar disk targets. In this contribution, we report on plasma diagnostics of a linear magnetron because the linear geometry is widely used in industry and, more importantly here, it provides the unique opportunity to align a linear racetrack section with a streak camera's entrance slit. This allows us to follow the evolution of plasma instabilities, i.e., localized ionization zones or spokes, as they travel along the racetrack. This report greatly extends our more limited and focused study on the structure and velocity of spokes [Anders and Yang, Appl. Phys. Lett. 111, 064103 (2017)]. Following recent plasma potential measurements [Panjan and Anders, J. Appl. Phys. 121, 063302 (2017)], we interpret optical emission information with localized electron heating. We confirm that for low direct current operation, spokes move in the -E ×B direction, and in the opposite direction in the high current mode. Streak images indicate slower spoke velocities near corners compared to spoke velocities in the straight sections of the racetrack. Spoke splitting and merging are observed supporting the interpretation that spoke motion represents a phase velocity of the region of greatest ionization and is not a motion of plasma. Fast camera investigations are supplemented by measurements of the energy distribution functions of ions emitted from the straight and curved regions of the racetrack, showing notable and reproducible differences.

  14. SPINS-IND: Pellet injector for fuelling of magnetically confined fusion systems.

    PubMed

    Gangradey, R; Mishra, J; Mukherjee, S; Panchal, P; Nayak, P; Agarwal, J; Saxena, Y C

    2017-06-01

    Using a Gifford-McMahon cycle cryocooler based refrigeration system, a single barrel hydrogen pellet injection (SPINS-IND) system is indigenously developed at Institute for Plasma Research, India. The injector is based on a pipe gun concept, where a pellet formed in situ in the gun barrel is accelerated to high speed using high pressure light propellant gas. The pellet size is decided by considering the Greenwald density limit and its speed is decided by considering a neutral gas shielding model based scaling law. The pellet shape is cylindrical of dimension (1.6 mm ℓ × 1.8 mm φ). For pellet ejection and acceleration, a fast opening valve of short opening duration is installed at the breech of the barrel. A three-stage differential pumping system is used to restrict the flow of the propellant gas into the plasma vacuum vessel. Diagnostic systems such as light gate and fast imaging camera (240 000 frames/s) are employed to measure the pellet speed and size, respectively. A trigger circuit and a programmable logic controller based integrated control system developed on LabVIEW enables to control the pellet injector remotely. Using helium as a propellant gas, the pellet speed is varied in the range 650 m/s-800 m/s. The reliability of pellet formation and ejection is found to be more than 95%. This paper describes the details of SPINS-IND and its test results.

  15. Reaction-time-resolved measurements of laser-induced fluorescence in a shock tube with a single laser pulse

    NASA Astrophysics Data System (ADS)

    Zabeti, S.; Fikri, M.; Schulz, C.

    2017-11-01

    Shock tubes allow for the study of ultra-fast gas-phase reactions on the microsecond time scale. Because the repetition rate of the experiments is low, it is crucial to gain as much information as possible from each individual measurement. While reaction-time-resolved species concentration and temperature measurements with fast absorption methods are established, conventional laser-induced fluorescence (LIF) measurements with pulsed lasers provide data only at a single reaction time. Therefore, fluorescence methods have rarely been used in shock-tube diagnostics. In this paper, a novel experimental concept is presented that allows reaction-time-resolved LIF measurements with one single laser pulse using a test section that is equipped with several optical ports. After the passage of the shock wave, the reactive mixture is excited along the center of the tube with a 266-nm laser beam directed through a window in the end wall of the shock tube. The emitted LIF signal is collected through elongated sidewall windows and focused onto the entrance slit of an imaging spectrometer coupled to an intensified CCD camera. The one-dimensional spatial resolution of the measurement translates into a reaction-time-resolved measurement while the species information can be gained from the spectral axis of the detected two-dimensional image. Anisole pyrolysis was selected as the benchmark reaction to demonstrate the new apparatus.

  16. SPINS-IND: Pellet injector for fuelling of magnetically confined fusion systems

    NASA Astrophysics Data System (ADS)

    Gangradey, R.; Mishra, J.; Mukherjee, S.; Panchal, P.; Nayak, P.; Agarwal, J.; Saxena, Y. C.

    2017-06-01

    Using a Gifford-McMahon cycle cryocooler based refrigeration system, a single barrel hydrogen pellet injection (SPINS-IND) system is indigenously developed at Institute for Plasma Research, India. The injector is based on a pipe gun concept, where a pellet formed in situ in the gun barrel is accelerated to high speed using high pressure light propellant gas. The pellet size is decided by considering the Greenwald density limit and its speed is decided by considering a neutral gas shielding model based scaling law. The pellet shape is cylindrical of dimension (1.6 mm ℓ × 1.8 mm φ). For pellet ejection and acceleration, a fast opening valve of short opening duration is installed at the breech of the barrel. A three-stage differential pumping system is used to restrict the flow of the propellant gas into the plasma vacuum vessel. Diagnostic systems such as light gate and fast imaging camera (240 000 frames/s) are employed to measure the pellet speed and size, respectively. A trigger circuit and a programmable logic controller based integrated control system developed on LabVIEW enables to control the pellet injector remotely. Using helium as a propellant gas, the pellet speed is varied in the range 650 m/s-800 m/s. The reliability of pellet formation and ejection is found to be more than 95%. This paper describes the details of SPINS-IND and its test results.

  17. Effect of Background Pressure on the Plasma Oscillation Characteristics of the HiVHAc Hall Thruster

    DTIC Science & Technology

    2014-06-01

    Hall thruster , a number of plasma diagnostics were implemented to study the effect of varying facility background pressure on thruster operation. These diagnostics characterized the thruster performance, the plume, and the plasma oscillations in the thruster. Thruster performance and plume characteristics as functions of background pressure were previously published. This paper will focus on changes in the plasma oscillation characteristics with changing background pressure. The diagnostics used to study plasma oscillations include a high-speed camera and a set of

  18. Plenoptic Imaging for Three-Dimensional Particle Field Diagnostics.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guildenbecher, Daniel Robert; Hall, Elise Munz

    2017-06-01

    Plenoptic imaging is a promising emerging technology for single-camera, 3D diagnostics of particle fields. In this work, recent developments towards quantitative measurements of particle size, positions, and velocities are discussed. First, the technique is proven viable with measurements of the particle field generated by the impact of a water drop on a thin film of water. Next, well cont rolled experiments are used to verify diagnostic uncertainty. Finally, an example is presented of 3D plenoptic imaging of a laboratory scale, explosively generated fragment field.

  19. Development of an EMC3-EIRENE Synthetic Imaging Diagnostic

    NASA Astrophysics Data System (ADS)

    Meyer, William; Allen, Steve; Samuell, Cameron; Lore, Jeremy

    2017-10-01

    2D and 3D flow measurements are critical for validating numerical codes such as EMC3-EIRENE. Toroidal symmetry assumptions preclude tomographic reconstruction of 3D flows from single camera views. In addition, the resolution of the grids utilized in numerical code models can easily surpass the resolution of physical camera diagnostic geometries. For these reasons we have developed a Synthetic Imaging Diagnostic capability for forward projection comparisons of EMC3-EIRENE model solutions with the line integrated images from the Doppler Coherence Imaging diagnostic on DIII-D. The forward projection matrix is 2.8 Mpixel by 6.4 Mcells for the non-axisymmetric case we present. For flow comparisons, both simple line integral, and field aligned component matrices must be calculated. The calculation of these matrices is a massive embarrassingly parallel problem and performed with a custom dispatcher that allows processing platforms to join mid-problem as they become available, or drop out if resources are needed for higher priority tasks. The matrices are handled using standard sparse matrix techniques. Prepared by LLNL under Contract DE-AC52-07NA27344. This material is based upon work supported by the U.S. DOE, Office of Science, Office of Fusion Energy Sciences. LLNL-ABS-734800.

  20. GoPro Hero Cameras for Creation of a Three-Dimensional, Educational, Neurointerventional Video.

    PubMed

    Park, Min S; Brock, Andrea; Mortimer, Vance; Taussky, Philipp; Couldwell, William T; Quigley, Edward

    2017-10-01

    Neurointerventional education relies on an apprenticeship model, with the trainee observing and participating in procedures with the guidance of a mentor. While educational videos are becoming prevalent in surgical cases, there is a dearth of comparable educational material for trainees in neurointerventional programs. We sought to create a high-quality, three-dimensional video of a routine diagnostic cerebral angiogram for use as an educational tool. A diagnostic cerebral angiogram was recorded using two GoPro HERO 3+ cameras with the Dual HERO System to capture the proceduralist's hands during the case. This video was edited with recordings from the video monitors to create a real-time three-dimensional video of both the actions of the neurointerventionalist and the resulting wire/catheter movements. The final edited video, in either two or three dimensions, can serve as another instructional tool for the training of residents and/or fellows. Additional videos can be created in a similar fashion of more complicated neurointerventional cases. The GoPro HERO 3+ camera and Dual HERO System can be used to create educational videos of neurointerventional procedures.

  1. Novel fast catadioptric objective with wide field of view

    NASA Astrophysics Data System (ADS)

    Muñoz, Fernando; Infante Herrero, José M.; Benítez, Pablo; Miñano, Juan C.; Lin, Wang; Vilaplana, Juan; Biot, Guillermo; de la Fuente, Marta

    2010-08-01

    Using the Simultaneous Multiple Surface method in 2D (SMS2D), we present a fast catadioptric objective with a wide field of view (125°×96°) designed for a microbolometer detector with 640×480 pixels and 25 microns pixel pitch Keywords: Infrared lens design, thermal imaging, Schwarzschild configuration, SMS2D, wide field of view, driving cameras, panoramic systems

  2. Beam measurements using visible synchrotron light at NSLS2 storage ring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, Weixing, E-mail: chengwx@bnl.gov; Bacha, Bel; Singh, Om

    2016-07-27

    Visible Synchrotron Light Monitor (SLM) diagnostic beamline has been designed and constructed at NSLS2 storage ring, to characterize the electron beam profile at various machine conditions. Due to the excellent alignment, SLM beamline was able to see the first visible light when beam was circulating the ring for the first turn. The beamline has been commissioned for the past year. Besides a normal CCD camera to monitor the beam profile, streak camera and gated camera are used to measure the longitudinal and transverse profile to understand the beam dynamics. Measurement results from these cameras will be presented in this paper.more » A time correlated single photon counting system (TCSPC) has also been setup to measure the single bunch purity.« less

  3. Search for GRB related prompt optical emission and other fast varying objects with ``Pi of the Sky'' detector

    NASA Astrophysics Data System (ADS)

    Ćwiok, M.; Dominik, W.; Małek, K.; Mankiewicz, L.; Mrowca-Ciułacz, J.; Nawrocki, K.; Piotrowski, L. W.; Sitek, P.; Sokołowski, M.; Wrochna, G.; Żarnecki, A. F.

    2007-06-01

    Experiment “Pi of the Sky” is designed to search for prompt optical emission from GRB sources. 32 CCD cameras covering 2 steradians will monitor the sky continuously. The data will be analysed on-line in search for optical flashes. The prototype with 2 cameras operated at Las Campanas (Chile) since 2004 has recognised several outbursts of flaring stars and has given limits for a few GRB.

  4. Orbit Tomography: A Method for Determining the Population of Individual Fast-ion Orbits from Experimental Measurements

    NASA Astrophysics Data System (ADS)

    Stagner, L.; Heidbrink, W. W.

    2017-10-01

    Due to the complicated nature of the fast-ion distribution function, diagnostic velocity-space weight functions are used to analyze experimental data. In a technique known as Velocity-space Tomography (VST), velocity-space weight functions are combined with experimental measurements to create a system of linear equations that can be solved. However, VST (which by definition ignores spatial dependencies) is restricted, both by the accuracy of its forward model and also by the availability of spatially overlapping diagnostics. In this work we extend velocity-space weight functions to a full 6D generalized coordinate system and then show how to reduce them to a 3D orbit-space without loss of generality using an action-angle formulation. Furthermore, we show how diagnostic orbit-weight functions can be used to infer the full fast-ion distribution function, i.e. Orbit Tomography. Examples of orbit weights functions for different diagnostics and reconstructions of fast-ion distributions are shown for DIII-D experiments. This work was supported by the U.S. Department of Energy under DE-AC02-09CH11466 and DE-FC02-04ER54698.

  5. Rapid detection of health-care-associated bloodstream infection in critical care using multipathogen real-time polymerase chain reaction technology: a diagnostic accuracy study and systematic review.

    PubMed

    Warhurst, Geoffrey; Dunn, Graham; Chadwick, Paul; Blackwood, Bronagh; McAuley, Daniel; Perkins, Gavin D; McMullan, Ronan; Gates, Simon; Bentley, Andrew; Young, Duncan; Carlson, Gordon L; Dark, Paul

    2015-05-01

    There is growing interest in the potential utility of real-time polymerase chain reaction (PCR) in diagnosing bloodstream infection by detecting pathogen deoxyribonucleic acid (DNA) in blood samples within a few hours. SeptiFast (Roche Diagnostics GmBH, Mannheim, Germany) is a multipathogen probe-based system targeting ribosomal DNA sequences of bacteria and fungi. It detects and identifies the commonest pathogens causing bloodstream infection. As background to this study, we report a systematic review of Phase III diagnostic accuracy studies of SeptiFast, which reveals uncertainty about its likely clinical utility based on widespread evidence of deficiencies in study design and reporting with a high risk of bias. Determine the accuracy of SeptiFast real-time PCR for the detection of health-care-associated bloodstream infection, against standard microbiological culture. Prospective multicentre Phase III clinical diagnostic accuracy study using the standards for the reporting of diagnostic accuracy studies criteria. Critical care departments within NHS hospitals in the north-west of England. Adult patients requiring blood culture (BC) when developing new signs of systemic inflammation. SeptiFast real-time PCR results at species/genus level compared with microbiological culture in association with independent adjudication of infection. Metrics of diagnostic accuracy were derived including sensitivity, specificity, likelihood ratios and predictive values, with their 95% confidence intervals (CIs). Latent class analysis was used to explore the diagnostic performance of culture as a reference standard. Of 1006 new patient episodes of systemic inflammation in 853 patients, 922 (92%) met the inclusion criteria and provided sufficient information for analysis. Index test assay failure occurred on 69 (7%) occasions. Adult patients had been exposed to a median of 8 days (interquartile range 4-16 days) of hospital care, had high levels of organ support activities and recent antibiotic exposure. SeptiFast real-time PCR, when compared with culture-proven bloodstream infection at species/genus level, had better specificity (85.8%, 95% CI 83.3% to 88.1%) than sensitivity (50%, 95% CI 39.1% to 60.8%). When compared with pooled diagnostic metrics derived from our systematic review, our clinical study revealed lower test accuracy of SeptiFast real-time PCR, mainly as a result of low diagnostic sensitivity. There was a low prevalence of BC-proven pathogens in these patients (9.2%, 95% CI 7.4% to 11.2%) such that the post-test probabilities of both a positive (26.3%, 95% CI 19.8% to 33.7%) and a negative SeptiFast test (5.6%, 95% CI 4.1% to 7.4%) indicate the potential limitations of this technology in the diagnosis of bloodstream infection. However, latent class analysis indicates that BC has a low sensitivity, questioning its relevance as a reference test in this setting. Using this analysis approach, the sensitivity of the SeptiFast test was low but also appeared significantly better than BC. Blood samples identified as positive by either culture or SeptiFast real-time PCR were associated with a high probability (> 95%) of infection, indicating higher diagnostic rule-in utility than was apparent using conventional analyses of diagnostic accuracy. SeptiFast real-time PCR on blood samples may have rapid rule-in utility for the diagnosis of health-care-associated bloodstream infection but the lack of sensitivity is a significant limiting factor. Innovations aimed at improved diagnostic sensitivity of real-time PCR in this setting are urgently required. Future work recommendations include technology developments to improve the efficiency of pathogen DNA extraction and the capacity to detect a much broader range of pathogens and drug resistance genes and the application of new statistical approaches able to more reliably assess test performance in situation where the reference standard (e.g. blood culture in the setting of high antimicrobial use) is prone to error. The systematic review is registered as PROSPERO CRD42011001289. The National Institute for Health Research Health Technology Assessment programme. Professor Daniel McAuley and Professor Gavin D Perkins contributed to the systematic review through their funded roles as codirectors of the Intensive Care Foundation (UK).

  6. Polarization sensitive camera for the in vitro diagnostic and monitoring of dental erosion

    NASA Astrophysics Data System (ADS)

    Bossen, Anke; Rakhmatullina, Ekaterina; Lussi, Adrian; Meier, Christoph

    Due to a frequent consumption of acidic food and beverages, the prevalence of dental erosion increases worldwide. In an initial erosion stage, the hard dental tissue is softened due to acidic demineralization. As erosion progresses, a gradual tissue wear occurs resulting in thinning of the enamel. Complete loss of the enamel tissue can be observed in severe clinical cases. Therefore, it is essential to provide a diagnosis tool for an accurate detection and monitoring of dental erosion already at early stages. In this manuscript, we present the development of a polarization sensitive imaging camera for the visualization and quantification of dental erosion. The system consists of two CMOS cameras mounted on two sides of a polarizing beamsplitter. A horizontal linearly polarized light source is positioned orthogonal to the camera to ensure an incidence illumination and detection angles of 45°. The specular reflected light from the enamel surface is collected with an objective lens mounted on the beam splitter and divided into horizontal (H) and vertical (V) components on each associate camera. Images of non-eroded and eroded enamel surfaces at different erosion degrees were recorded and assessed with diagnostic software. The software was designed to generate and display two types of images: distribution of the reflection intensity (V) and a polarization ratio (H-V)/(H+V) throughout the analyzed tissue area. The measurements and visualization of these two optical parameters, i.e. specular reflection intensity and the polarization ratio, allowed detection and quantification of enamel erosion at early stages in vitro.

  7. X-ray pinhole camera setups used in the Atomki ECR Laboratory for plasma diagnostics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rácz, R., E-mail: rracz@atomki.hu; Biri, S.; Pálinkás, J.

    Imaging of the electron cyclotron resonance (ECR) plasmas by using CCD camera in combination with a pinhole is a non-destructive diagnostics method to record the strongly inhomogeneous spatial density distribution of the X-ray emitted by the plasma and by the chamber walls. This method can provide information on the location of the collisions between warm electrons and multiple charged ions/atoms, opening the possibility to investigate the direct effect of the ion source tuning parameters to the plasma structure. The first successful experiment with a pinhole X-ray camera was carried out in the Atomki ECR Laboratory more than 10 years ago.more » The goal of that experiment was to make the first ECR X-ray photos and to carry out simple studies on the effect of some setting parameters (magnetic field, extraction, disc voltage, gas mixing, etc.). Recently, intensive efforts were taken to investigate now the effect of different RF resonant modes to the plasma structure. Comparing to the 2002 experiment, this campaign used wider instrumental stock: CCD camera with a lead pinhole was placed at the injection side allowing X-ray imaging and beam extraction simultaneously. Additionally, Silicon Drift Detector (SDD) and High Purity Germanium (HPGe) detectors were installed to characterize the volumetric X-ray emission rate caused by the warm and hot electron domains. In this paper, detailed comparison study on the two X-ray camera and detector setups and also on the technical and scientific goals of the experiments is presented.« less

  8. Super-Resolution in Plenoptic Cameras Using FPGAs

    PubMed Central

    Pérez, Joel; Magdaleno, Eduardo; Pérez, Fernando; Rodríguez, Manuel; Hernández, David; Corrales, Jaime

    2014-01-01

    Plenoptic cameras are a new type of sensor that extend the possibilities of current commercial cameras allowing 3D refocusing or the capture of 3D depths. One of the limitations of plenoptic cameras is their limited spatial resolution. In this paper we describe a fast, specialized hardware implementation of a super-resolution algorithm for plenoptic cameras. The algorithm has been designed for field programmable graphic array (FPGA) devices using VHDL (very high speed integrated circuit (VHSIC) hardware description language). With this technology, we obtain an acceleration of several orders of magnitude using its extremely high-performance signal processing capability through parallelism and pipeline architecture. The system has been developed using generics of the VHDL language. This allows a very versatile and parameterizable system. The system user can easily modify parameters such as data width, number of microlenses of the plenoptic camera, their size and shape, and the super-resolution factor. The speed of the algorithm in FPGA has been successfully compared with the execution using a conventional computer for several image sizes and different 3D refocusing planes. PMID:24841246

  9. Super-resolution in plenoptic cameras using FPGAs.

    PubMed

    Pérez, Joel; Magdaleno, Eduardo; Pérez, Fernando; Rodríguez, Manuel; Hernández, David; Corrales, Jaime

    2014-05-16

    Plenoptic cameras are a new type of sensor that extend the possibilities of current commercial cameras allowing 3D refocusing or the capture of 3D depths. One of the limitations of plenoptic cameras is their limited spatial resolution. In this paper we describe a fast, specialized hardware implementation of a super-resolution algorithm for plenoptic cameras. The algorithm has been designed for field programmable graphic array (FPGA) devices using VHDL (very high speed integrated circuit (VHSIC) hardware description language). With this technology, we obtain an acceleration of several orders of magnitude using its extremely high-performance signal processing capability through parallelism and pipeline architecture. The system has been developed using generics of the VHDL language. This allows a very versatile and parameterizable system. The system user can easily modify parameters such as data width, number of microlenses of the plenoptic camera, their size and shape, and the super-resolution factor. The speed of the algorithm in FPGA has been successfully compared with the execution using a conventional computer for several image sizes and different 3D refocusing planes.

  10. Completely optical orientation determination for an unstabilized aerial three-line camera

    NASA Astrophysics Data System (ADS)

    Wohlfeil, Jürgen

    2010-10-01

    Aerial line cameras allow the fast acquisition of high-resolution images at low costs. Unfortunately the measurement of the camera's orientation with the necessary rate and precision is related with large effort, unless extensive camera stabilization is used. But also stabilization implicates high costs, weight, and power consumption. This contribution shows that it is possible to completely derive the absolute exterior orientation of an unstabilized line camera from its images and global position measurements. The presented approach is based on previous work on the determination of the relative orientation of subsequent lines using optical information from the remote sensing system. The relative orientation is used to pre-correct the line images, in which homologous points can reliably be determined using the SURF operator. Together with the position measurements these points are used to determine the absolute orientation from the relative orientations via bundle adjustment of a block of overlapping line images. The approach was tested at a flight with the DLR's RGB three-line camera MFC. To evaluate the precision of the resulting orientation the measurements of a high-end navigation system and ground control points are used.

  11. Collective Thomson scattering measurements of fast-ion transport due to sawtooth crashes in ASDEX Upgrade

    NASA Astrophysics Data System (ADS)

    Rasmussen, J.; Nielsen, S. K.; Stejner, M.; Galdon-Quiroga, J.; Garcia-Munoz, M.; Geiger, B.; Jacobsen, A. S.; Jaulmes, F.; Korsholm, S. B.; Lazanyi, N.; Leipold, F.; Ryter, F.; Salewski, M.; Schubert, M.; Stober, J.; Wagner, D.; the ASDEX Upgrade Team; the EUROFusion MST1 Team

    2016-11-01

    Sawtooth instabilities can modify heating and current-drive profiles and potentially increase fast-ion losses. Understanding how sawteeth redistribute fast ions as a function of sawtooth parameters and of fast-ion energy and pitch is hence a subject of particular interest for future fusion devices. Here we present the first collective Thomson scattering (CTS) measurements of sawtooth-induced redistribution of fast ions at ASDEX Upgrade. These also represent the first localized fast-ion measurements on the high-field side of this device. The results indicate fast-ion losses in the phase-space measurement volume of about 50% across sawtooth crashes, in good agreement with values predicted with the Kadomtsev sawtooth model implemented in TRANSP and with the sawtooth model in the EBdyna_go code. In contrast to the case of sawteeth, we observe no fast-ion redistribution in the presence of fishbone modes. We highlight how CTS measurements can discriminate between different sawtooth models, in particular when aided by multi-diagnostic velocity-space tomography, and briefly discuss our results in light of existing measurements from other fast-ion diagnostics.

  12. Differential effects of film on preschool children's behaviour dependent on editing pace.

    PubMed

    Kostyrka-Allchorne, Katarzyna; Cooper, Nicholas R; Gossmann, Anna Maria; Barber, Katy J; Simpson, Andrew

    2017-05-01

    Evidence on how the pace of television and film editing affects children's behaviour and attention is inconclusive. We examined whether a fast-paced film affected how preschool-aged children interacted with toys. The study comprised 70 children (36 girls) aged two to four-and-a-half years who attended preschools in Essex, United Kingdom. The children were paired up and tested with either a fast- or a slow-paced film of a narrator reading a children's story. The fast-paced version had 102 camera cuts and 16 still images, and the slow-paced version had 22 camera cuts and four still images. Each dyad took part in two video-recorded free-play sessions, before and after they watched one of the specially edited four-minute films. The number of toys the children played with before and after the film sessions was recorded. Before they watched the films, the children's behaviour did not differ between the groups. However, after watching the film, the children in the fast-paced group shifted their attention between toys more frequently than the children who watched the slow-paced film. Even a brief exposure to differently paced films had an immediate effect on how the children interacted with their toys. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  13. Can light-field photography ease focusing on the scalp and oral cavity?

    PubMed

    Taheri, Arash; Feldman, Steven R

    2013-08-01

    Capturing a well-focused image using an autofocus camera can be difficult in oral cavity and on a hairy scalp. Light-field digital cameras capture data regarding the color, intensity, and direction of rays of light. Having information regarding direction of rays of light, computer software can be used to focus on different subjects in the field after the image data have been captured. A light-field camera was used to capture the images of the scalp and oral cavity. The related computer software was used to focus on scalp or different parts of oral cavity. The final pictures were compared with pictures taken with conventional, compact, digital cameras. The camera worked well for oral cavity. It also captured the pictures of scalp easily; however, we had to repeat clicking between the hairs on different points to choose the scalp for focusing. A major drawback of the system was the resolution of the resulting pictures that was lower than conventional digital cameras. Light-field digital cameras are fast and easy to use. They can capture more information on the full depth of field compared with conventional cameras. However, the resolution of the pictures is relatively low. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. First results of the multi-purpose real-time processing video camera system on the Wendelstein 7-X stellarator and implications for future devices

    NASA Astrophysics Data System (ADS)

    Zoletnik, S.; Biedermann, C.; Cseh, G.; Kocsis, G.; König, R.; Szabolics, T.; Szepesi, T.; Wendelstein 7-X Team

    2018-01-01

    A special video camera has been developed for the 10-camera overview video system of the Wendelstein 7-X (W7-X) stellarator considering multiple application needs and limitations resulting from this complex long-pulse superconducting stellarator experiment. The event detection intelligent camera (EDICAM) uses a special 1.3 Mpixel CMOS sensor with non-destructive read capability which enables fast monitoring of smaller Regions of Interest (ROIs) even during long exposures. The camera can perform simple data evaluation algorithms (minimum/maximum, mean comparison to levels) on the ROI data which can dynamically change the readout process and generate output signals. Multiple EDICAM cameras were operated in the first campaign of W7-X and capabilities were explored in the real environment. Data prove that the camera can be used for taking long exposure (10-100 ms) overview images of the plasma while sub-ms monitoring and even multi-camera correlated edge plasma turbulence measurements of smaller areas can be done in parallel. These latter revealed that filamentary turbulence structures extend between neighboring modules of the stellarator. Considerations emerging for future upgrades of this system and similar setups on future long-pulse fusion experiments such as ITER are discussed.

  15. HST PSF simulation using Tiny Tim

    NASA Technical Reports Server (NTRS)

    Krist, J. E.

    1992-01-01

    Tiny Tim is a program which simulates Hubble Space Telescope imaging camera PSF's. It is portable (written and distributed in C) and is reasonably fast. It can model the WFPC, WFPC 2, FOC, and COSTAR corrected FOC cameras. In addition to aberrations such as defocus and spherical, it also includes WFPC obscuration shifting, mirror zonal error maps, and jitter. The program has been used at a number of sites for deconvolving HST images. Tiny Tim is available via anonymous ftp on stsci.edu in the directory software/tinytim.

  16. ePix100 camera: Use and applications at LCLS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carini, G. A., E-mail: carini@slac.stanford.edu; Alonso-Mori, R.; Blaj, G.

    2016-07-27

    The ePix100 x-ray camera is a new system designed and built at SLAC for experiments at the Linac Coherent Light Source (LCLS). The camera is the first member of a family of detectors built around a single hardware and software platform, supporting a variety of front-end chips. With a readout speed of 120 Hz, matching the LCLS repetition rate, a noise lower than 80 e-rms and pixels of 50 µm × 50 µm, this camera offers a viable alternative to fast readout, direct conversion, scientific CCDs in imaging mode. The detector, designed for applications such as X-ray Photon Correlation Spectroscopymore » (XPCS) and wavelength dispersive X-ray Emission Spectroscopy (XES) in the energy range from 2 to 10 keV and above, comprises up to 0.5 Mpixels in a very compact form factor. In this paper, we report the performance of the camera during its first use at LCLS.« less

  17. Analysis of edge density fluctuation measured by trial KSTAR beam emission spectroscopy systema)

    NASA Astrophysics Data System (ADS)

    Nam, Y. U.; Zoletnik, S.; Lampert, M.; Kovácsik, Á.

    2012-10-01

    A beam emission spectroscopy (BES) system based on direct imaging avalanche photodiode (APD) camera has been designed for Korea Superconducting Tokamak Advanced Research (KSTAR) and a trial system has been constructed and installed for evaluating feasibility of the design. The system contains two cameras, one is an APD camera for BES measurement and another is a fast visible camera for position calibration. Two pneumatically actuated mirrors were positioned at front and rear of lens optics. The front mirror can switch the measurement between edge and core region of plasma and the rear mirror can switch between the APD and the visible camera. All systems worked properly and the measured photon flux was reasonable as expected from the simulation. While the measurement data from the trial system were limited, it revealed some interesting characteristics of KSTAR plasma suggesting future research works with fully installed BES system. The analysis result and the development plan will be presented in this paper.

  18. Registration of retinal sequences from new video-ophthalmoscopic camera.

    PubMed

    Kolar, Radim; Tornow, Ralf P; Odstrcilik, Jan; Liberdova, Ivana

    2016-05-20

    Analysis of fast temporal changes on retinas has become an important part of diagnostic video-ophthalmology. It enables investigation of the hemodynamic processes in retinal tissue, e.g. blood-vessel diameter changes as a result of blood-pressure variation, spontaneous venous pulsation influenced by intracranial-intraocular pressure difference, blood-volume changes as a result of changes in light reflection from retinal tissue, and blood flow using laser speckle contrast imaging. For such applications, image registration of the recorded sequence must be performed. Here we use a new non-mydriatic video-ophthalmoscope for simple and fast acquisition of low SNR retinal sequences. We introduce a novel, two-step approach for fast image registration. The phase correlation in the first stage removes large eye movements. Lucas-Kanade tracking in the second stage removes small eye movements. We propose robust adaptive selection of the tracking points, which is the most important part of tracking-based approaches. We also describe a method for quantitative evaluation of the registration results, based on vascular tree intensity profiles. The achieved registration error evaluated on 23 sequences (5840 frames) is 0.78 ± 0.67 pixels inside the optic disc and 1.39 ± 0.63 pixels outside the optic disc. We compared the results with the commonly used approaches based on Lucas-Kanade tracking and scale-invariant feature transform, which achieved worse results. The proposed method can efficiently correct particular frames of retinal sequences for shift and rotation. The registration results for each frame (shift in X and Y direction and eye rotation) can also be used for eye-movement evaluation during single-spot fixation tasks.

  19. Geometric Calibration and Radiometric Correction of the Maia Multispectral Camera

    NASA Astrophysics Data System (ADS)

    Nocerino, E.; Dubbini, M.; Menna, F.; Remondino, F.; Gattelli, M.; Covi, D.

    2017-10-01

    Multispectral imaging is a widely used remote sensing technique, whose applications range from agriculture to environmental monitoring, from food quality check to cultural heritage diagnostic. A variety of multispectral imaging sensors are available on the market, many of them designed to be mounted on different platform, especially small drones. This work focuses on the geometric and radiometric characterization of a brand-new, lightweight, low-cost multispectral camera, called MAIA. The MAIA camera is equipped with nine sensors, allowing for the acquisition of images in the visible and near infrared parts of the electromagnetic spectrum. Two versions are available, characterised by different set of band-pass filters, inspired by the sensors mounted on the WorlView-2 and Sentinel2 satellites, respectively. The camera details and the developed procedures for the geometric calibrations and radiometric correction are presented in the paper.

  20. Martian Terrain Near Curiosity Precipice Target

    NASA Image and Video Library

    2016-12-06

    This view from the Navigation Camera (Navcam) on the mast of NASA's Curiosity Mars rover shows rocky ground within view while the rover was working at an intended drilling site called "Precipice" on lower Mount Sharp. The right-eye camera of the stereo Navcam took this image on Dec. 2, 2016, during the 1,537th Martian day, or sol, of Curiosity's work on Mars. On the previous sol, an attempt to collect a rock-powder sample with the rover's drill ended before drilling began. This led to several days of diagnostic work while the rover remained in place, during which it continued to use cameras and a spectrometer on its mast, plus environmental monitoring instruments. In this view, hardware visible at lower right includes the sundial-theme calibration target for Curiosity's Mast Camera. http://photojournal.jpl.nasa.gov/catalog/PIA21140

  1. A new compact, high sensitivity neutron imaging systema)

    NASA Astrophysics Data System (ADS)

    Caillaud, T.; Landoas, O.; Briat, M.; Rossé, B.; Thfoin, I.; Philippe, F.; Casner, A.; Bourgade, J. L.; Disdier, L.; Glebov, V. Yu.; Marshall, F. J.; Sangster, T. C.; Park, H. S.; Robey, H. F.; Amendt, P.

    2012-10-01

    We have developed a new small neutron imaging system (SNIS) diagnostic for the OMEGA laser facility. The SNIS uses a penumbral coded aperture and has been designed to record images from low yield (109-1010 neutrons) implosions such as those using deuterium as the fuel. This camera was tested at OMEGA in 2009 on a rugby hohlraum energetics experiment where it recorded an image at a yield of 1.4 × 1010. The resolution of this image was 54 μm and the camera was located only 4 meters from target chamber centre. We recently improved the instrument by adding a cooled CCD camera. The sensitivity of the new camera has been fully characterized using a linear accelerator and a 60Co γ-ray source. The calibration showed that the signal-to-noise ratio could be improved by using raw binning detection.

  2. Spectral survey of helium lines in a linear plasma device for use in HELIOS imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ray, H. B., E-mail: rayhb@ornl.gov; Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831; Biewer, T. M.

    2016-11-15

    Fast visible cameras and a filterscope are used to examine the visible light emission from Oak Ridge National Laboratory’s Proto-MPEX. The filterscope has been configured to perform helium line ratio measurements using emission lines at 667.9, 728.1, and 706.5 nm. The measured lines should be mathematically inverted and the ratios compared to a collisional radiative model (CRM) to determine T{sub e} and n{sub e}. Increasing the number of measurement chords through the plasma improves the inversion calculation and subsequent T{sub e} and n{sub e} localization. For the filterscope, one spatial chord measurement requires three photomultiplier tubes (PMTs) connected to pelliclemore » beam splitters. Multiple, fast visible cameras with narrowband filters are an alternate technique for performing these measurements with superior spatial resolution. Each camera contains millions of pixels; each pixel is analogous to one filterscope PMT. The data can then be inverted and the ratios compared to the CRM to determine 2-dimensional “images” of T{sub e} and n{sub e} in the plasma. An assessment is made in this paper of the candidate He I emission lines for an imaging technique.« less

  3. Particle displacement tracking applied to air flows

    NASA Technical Reports Server (NTRS)

    Wernet, Mark P.

    1991-01-01

    Electronic Particle Image Velocimeter (PIV) techniques offer many advantages over conventional photographic PIV methods such as fast turn around times and simplified data reduction. A new all electronic PIV technique was developed which can measure high speed gas velocities. The Particle Displacement Tracking (PDT) technique employs a single cw laser, small seed particles (1 micron), and a single intensified, gated CCD array frame camera to provide a simple and fast method of obtaining two-dimensional velocity vector maps with unambiguous direction determination. Use of a single CCD camera eliminates registration difficulties encountered when multiple cameras are used to obtain velocity magnitude and direction information. An 80386 PC equipped with a large memory buffer frame-grabber board provides all of the data acquisition and data reduction operations. No array processors of other numerical processing hardware are required. Full video resolution (640x480 pixel) is maintained in the acquired images, providing high resolution video frames of the recorded particle images. The time between data acquisition to display of the velocity vector map is less than 40 sec. The new electronic PDT technique is demonstrated on an air nozzle flow with velocities less than 150 m/s.

  4. Fast Markerless Tracking for Augmented Reality in Planar Environment

    NASA Astrophysics Data System (ADS)

    Basori, Ahmad Hoirul; Afif, Fadhil Noer; Almazyad, Abdulaziz S.; AbuJabal, Hamza Ali S.; Rehman, Amjad; Alkawaz, Mohammed Hazim

    2015-12-01

    Markerless tracking for augmented reality should not only be accurate but also fast enough to provide a seamless synchronization between real and virtual beings. Current reported methods showed that a vision-based tracking is accurate but requires high computational power. This paper proposes a real-time hybrid-based method for tracking unknown environments in markerless augmented reality. The proposed method provides collaboration of vision-based approach with accelerometers and gyroscopes sensors as camera pose predictor. To align the augmentation relative to camera motion, the tracking method is done by substituting feature-based camera estimation with combination of inertial sensors with complementary filter to provide more dynamic response. The proposed method managed to track unknown environment with faster processing time compared to available feature-based approaches. Moreover, the proposed method can sustain its estimation in a situation where feature-based tracking loses its track. The collaboration of sensor tracking managed to perform the task for about 22.97 FPS, up to five times faster than feature-based tracking method used as comparison. Therefore, the proposed method can be used to track unknown environments without depending on amount of features on scene, while requiring lower computational cost.

  5. Design of microcontroller based system for automation of streak camera.

    PubMed

    Joshi, M J; Upadhyay, J; Deshpande, P P; Sharma, M L; Navathe, C P

    2010-08-01

    A microcontroller based system has been developed for automation of the S-20 optical streak camera, which is used as a diagnostic tool to measure ultrafast light phenomenon. An 8 bit MCS family microcontroller is employed to generate all control signals for the streak camera. All biasing voltages required for various electrodes of the tubes are generated using dc-to-dc converters. A high voltage ramp signal is generated through a step generator unit followed by an integrator circuit and is applied to the camera's deflecting plates. The slope of the ramp can be changed by varying values of the capacitor and inductor. A programmable digital delay generator has been developed for synchronization of ramp signal with the optical signal. An independent hardwired interlock circuit has been developed for machine safety. A LABVIEW based graphical user interface has been developed which enables the user to program the settings of the camera and capture the image. The image is displayed with intensity profiles along horizontal and vertical axes. The streak camera was calibrated using nanosecond and femtosecond lasers.

  6. Design of microcontroller based system for automation of streak camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joshi, M. J.; Upadhyay, J.; Deshpande, P. P.

    2010-08-15

    A microcontroller based system has been developed for automation of the S-20 optical streak camera, which is used as a diagnostic tool to measure ultrafast light phenomenon. An 8 bit MCS family microcontroller is employed to generate all control signals for the streak camera. All biasing voltages required for various electrodes of the tubes are generated using dc-to-dc converters. A high voltage ramp signal is generated through a step generator unit followed by an integrator circuit and is applied to the camera's deflecting plates. The slope of the ramp can be changed by varying values of the capacitor and inductor.more » A programmable digital delay generator has been developed for synchronization of ramp signal with the optical signal. An independent hardwired interlock circuit has been developed for machine safety. A LABVIEW based graphical user interface has been developed which enables the user to program the settings of the camera and capture the image. The image is displayed with intensity profiles along horizontal and vertical axes. The streak camera was calibrated using nanosecond and femtosecond lasers.« less

  7. Instrumentation for localized superconducting cavity diagnostics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conway, Z. A.; Ge, M.; Iwashita, Y.

    2017-01-12

    Superconducting accelerator cavities are now routinely operated at levels approaching the theoretical limit of niobium. To achieve these operating levels more information than is available from the RF excitation signal is required to characterize and determine fixes for the sources of performance limitations. This information is obtained using diagnostic techniques which complement the analysis of the RF signal. In this paper we describe the operation and select results from three of these diagnostic techniques: the use of large scale thermometer arrays, second sound wave defect location and high precision cavity imaging with the Kyoto camera.

  8. Measuring Beam Sizes and Ultra-Small Electron Emittances Using an X-ray Pinhole Camera.

    PubMed

    Elleaume, P; Fortgang, C; Penel, C; Tarazona, E

    1995-09-01

    A very simple pinhole camera set-up has been built to diagnose the electron beam emittance of the ESRF. The pinhole is placed in the air next to an Al window. An image is obtained with a CCD camera imaging a fluorescent screen. The emittance is deduced from the size of the image. The relationship between the measured beam size and the electron beam emittance depends upon the lattice functions alpha, beta and eta, the screen resolution, pinhole size and photon beam divergence. The set-up is capable of measuring emittances as low as 5 pm rad and is presently routinely used as both an electron beam imaging device and an emittance diagnostic.

  9. Data management software concept for WEST plasma measurement system

    NASA Astrophysics Data System (ADS)

    Zienkiewicz, P.; Kasprowicz, G.; Byszuk, A.; Wojeński, A.; Kolasinski, P.; Cieszewski, R.; Czarski, T.; Chernyshova, M.; Pozniak, K.; Zabolotny, W.; Juszczyk, B.; Mazon, D.; Malard, P.

    2014-11-01

    This paper describes the concept of data management software for the multichannel readout system for the GEM detector used in WEST Plasma experiment. The proposed system consists of three separate communication channels: fast data channel, diagnostics channel, slow data channel. Fast data channel is provided by the FPGA with integrated ARM cores providing direct readout data from Analog Front Ends through 10GbE with short, guaranteed intervals. Slow data channel is provided by multiple, fast CPUs after data processing with detailed readout data with use of GNU/Linux OS and appropriate software. Diagnostic channel provides detailed feedback for control purposes.

  10. Performance evaluation for pinhole collimators of small gamma camera by MTF and NNPS analysis: Monte Carlo simulation study

    NASA Astrophysics Data System (ADS)

    Jeon, Hosang; Kim, Hyunduk; Cha, Bo Kyung; Kim, Jong Yul; Cho, Gyuseong; Chung, Yong Hyun; Yun, Jong-Il

    2009-06-01

    Presently, the gamma camera system is widely used in various medical diagnostic, industrial and environmental fields. Hence, the quantitative and effective evaluation of its imaging performance is essential for design and quality assurance. The National Electrical Manufacturers Association (NEMA) standards for gamma camera evaluation are insufficient to perform sensitive evaluation. In this study, modulation transfer function (MTF) and normalized noise power spectrum (NNPS) will be suggested to evaluate the performance of small gamma camera with changeable pinhole collimators using Monte Carlo simulation. We simulated the system with a cylinder and a disk source, and seven different pinhole collimators from 1- to 4-mm-diameter pinhole with lead. The MTF and NNPS data were obtained from output images and were compared with full-width at half-maximum (FWHM), sensitivity and differential uniformity. In the result, we found that MTF and NNPS are effective and novel standards to evaluate imaging performance of gamma cameras instead of conventional NEMA standards.

  11. A fast new cadioptric design for fiber-fed spectrographs

    NASA Astrophysics Data System (ADS)

    Saunders, Will

    2012-09-01

    The next generation of massively multiplexed multi-object spectrographs (DESpec, SUMIRE, BigBOSS, 4MOST, HECTOR) demand fast, efficient and affordable spectrographs, with higher resolutions (R = 3000-5000) than current designs. Beam-size is a (relatively) free parameter in the design, but the properties of VPH gratings are such that, for fixed resolution and wavelength coverage, the effect on beam-size on overall VPH efficiency is very small. For alltransmissive cameras, this suggests modest beam-sizes (say 80-150mm) to minimize costs; while for cadioptric (Schmidt-type) cameras, much larger beam-sizes (say 250mm+) are preferred to improve image quality and to minimize obstruction losses. Schmidt designs have benefits in terms of image quality, camera speed and scattered light performance, and recent advances such as MRF technology mean that the required aspherics are no longer a prohibitive cost or risk. The main objections to traditional Schmidt designs are the inaccessibility of the detector package, and the loss in throughput caused by it being in the beam. With expected count rates and current read-noise technology, the gain in camera speed allowed by Schmidt optics largely compensates for the additional obstruction losses. However, future advances in readout technology may erase most of this compensation. A new Schmidt/Maksutov-derived design is presented, which differs from previous designs in having the detector package outside the camera, and adjacent to the spectrograph pupil. The telescope pupil already contains a hole at its center, because of the obstruction from the telescope top-end. With a 250mm beam, it is possible to largely hide a 6cm × 6cm detector package and its dewar within this hole. This means that the design achieves a very high efficiency, competitive with transmissive designs. The optics are excellent, as least as good as classic Schmidt designs, allowing F/1.25 or even faster cameras. The principal hardware has been costed at $300K per arm, making the design affordable.

  12. Measuring SO2 ship emissions with an ultra-violet imaging camera

    NASA Astrophysics Data System (ADS)

    Prata, A. J.

    2013-11-01

    Over the last few years fast-sampling ultra-violet (UV) imaging cameras have been developed for use in measuring SO2 emissions from industrial sources (e.g. power plants; typical fluxes ~1-10 kg s-1) and natural sources (e.g. volcanoes; typical fluxes ~10-100 kg s-1). Generally, measurements have been made from sources rich in SO2 with high concentrations and fluxes. In this work, for the first time, a UV camera has been used to measure the much lower concentrations and fluxes of SO2 (typical fluxes ~0.01-0.1 kg s-1) in the plumes from moving and stationary ships. Some innovations and trade-offs have been made so that estimates of the fluxes and path concentrations can be retrieved in real-time. Field experiments were conducted at Kongsfjord in Ny Ålesund, Svalbard, where emissions from cruise ships were made, and at the port of Rotterdam, Netherlands, measuring emissions from more than 10 different container and cargo ships. In all cases SO2 path concentrations could be estimated and fluxes determined by measuring ship plume speeds simultaneously using the camera, or by using surface wind speed data from an independent source. Accuracies were compromised in some cases because of the presence of particulates in some ship emissions and the restriction of single-filter UV imagery, a requirement for fast-sampling (>10 Hz) from a single camera. Typical accuracies ranged from 10-30% in path concentration and 10-40% in flux estimation. Despite the ease of use and ability to determine SO2 fluxes from the UV camera system, the limitation in accuracy and precision suggest that the system may only be used under rather ideal circumstances and that currently the technology needs further development to serve as a method to monitor ship emissions for regulatory purposes.

  13. Flexible mini gamma camera reconstructions of extended sources using step and shoot and list mode.

    PubMed

    Gardiazabal, José; Matthies, Philipp; Vogel, Jakob; Frisch, Benjamin; Navab, Nassir; Ziegler, Sibylle; Lasser, Tobias

    2016-12-01

    Hand- and robot-guided mini gamma cameras have been introduced for the acquisition of single-photon emission computed tomography (SPECT) images. Less cumbersome than whole-body scanners, they allow for a fast acquisition of the radioactivity distribution, for example, to differentiate cancerous from hormonally hyperactive lesions inside the thyroid. This work compares acquisition protocols and reconstruction algorithms in an attempt to identify the most suitable approach for fast acquisition and efficient image reconstruction, suitable for localization of extended sources, such as lesions inside the thyroid. Our setup consists of a mini gamma camera with precise tracking information provided by a robotic arm, which also provides reproducible positioning for our experiments. Based on a realistic phantom of the thyroid including hot and cold nodules as well as background radioactivity, the authors compare "step and shoot" (SAS) and continuous data (CD) acquisition protocols in combination with two different statistical reconstruction methods: maximum-likelihood expectation-maximization (ML-EM) for time-integrated count values and list-mode expectation-maximization (LM-EM) for individually detected gamma rays. In addition, the authors simulate lower uptake values by statistically subsampling the experimental data in order to study the behavior of their approach without changing other aspects of the acquired data. All compared methods yield suitable results, resolving the hot nodules and the cold nodule from the background. However, the CD acquisition is twice as fast as the SAS acquisition, while yielding better coverage of the thyroid phantom, resulting in qualitatively more accurate reconstructions of the isthmus between the lobes. For CD acquisitions, the LM-EM reconstruction method is preferable, as it yields comparable image quality to ML-EM at significantly higher speeds, on average by an order of magnitude. This work identifies CD acquisition protocols combined with LM-EM reconstruction as a prime candidate for the wider introduction of SPECT imaging with flexible mini gamma cameras in the clinical practice.

  14. Object tracking using multiple camera video streams

    NASA Astrophysics Data System (ADS)

    Mehrubeoglu, Mehrube; Rojas, Diego; McLauchlan, Lifford

    2010-05-01

    Two synchronized cameras are utilized to obtain independent video streams to detect moving objects from two different viewing angles. The video frames are directly correlated in time. Moving objects in image frames from the two cameras are identified and tagged for tracking. One advantage of such a system involves overcoming effects of occlusions that could result in an object in partial or full view in one camera, when the same object is fully visible in another camera. Object registration is achieved by determining the location of common features in the moving object across simultaneous frames. Perspective differences are adjusted. Combining information from images from multiple cameras increases robustness of the tracking process. Motion tracking is achieved by determining anomalies caused by the objects' movement across frames in time in each and the combined video information. The path of each object is determined heuristically. Accuracy of detection is dependent on the speed of the object as well as variations in direction of motion. Fast cameras increase accuracy but limit the speed and complexity of the algorithm. Such an imaging system has applications in traffic analysis, surveillance and security, as well as object modeling from multi-view images. The system can easily be expanded by increasing the number of cameras such that there is an overlap between the scenes from at least two cameras in proximity. An object can then be tracked long distances or across multiple cameras continuously, applicable, for example, in wireless sensor networks for surveillance or navigation.

  15. Plasmakristall-4: A microgravity complex plasma facility on the way to launch

    NASA Astrophysics Data System (ADS)

    Pustylnik, Mikhail; Thomas, Hubertus; Fortov, Vladimir; Thoma, Markus; Lipaev, Andrey; Morfill, Gregor; Molotkov, Vladimir; Usachev, Alexander; Zobnin, Andrey; Tarantik, Karl; Albrecht, Sebastian; Deysenroth, Christian; Rau, Christian; Mitic, Slobodan; Nosenko, Vladimir; Fink, Martin; Prof

    Complex plasmas, a special case of dusty plasmas, are one of the most interesting physical objects to be studied under microgravity conditions. A way from dusty plasmas to complex plasmas was revealed when strong coupling phenomena in the dust subsystem were first theoretically predicted and then observed under ground laboratory conditions. Complex plasmas are, therefore, dusty plasmas, which are prepared intentionally to study generic phenomena of condensed matter physics. Complex plasmas have several advantages in this respect: Real-time, virtually undamped dynamics of the system can be resolved on the kinetic level, i.e. on the level of single microparticles. Under ground laboratory conditions the microparticles are strongly affected by the gravitational force, which has to be compensated by strong electrostatic forces. Therefore, the volume occupied by the microparticles is limited to sheath region. This makes formation of uniform 3D structures under ground condition almost impossible. Microgravity is therefore essential for studying 3D complex plasma systems. The next lab for complex plasma research under mug-conditions will be PK-4, a joint Russian-European project. The special feature of PK-4 (with respect to its predecessor PK-3 Plus on the ISS) is that it will allow to study the fluid phenomena. Geometry of the plasma chamber (a glass tube with the working part of about 200 mm long and 30 mm diameter) implies presence of micropaticle flows along its axis. A custom-made power supply will create either a DC or polarity-switched discharge inside the chamber filled with either neon or argon. In the DC mode the negatively-charged microparticles will drift opposite to the electric field. Polarity switching can be done with up to several kHz frequency, which will allow the discharge to change polarity, whereas heavy microparticles will be insensitive to such fast variations of the electric field. In this way, microparticles will be trapped inside the plasma chamber. For the diagnostics of the microparticles, two CCD cameras and an illumination laser sheet are available. Cameras and the laser focal plane are movable along the plasma chamber and cover almost the entire working area. Moving the laser sheet and cameras across the plasma chamber axis will allow to obtain information on the 3D structure of the microparticle clouds. Background plasma may be monitored by the so-called plasma glow camera, which produces three kaleidoscopic images of the plasma. Two of these images are filtered for two neon spectral lines and the third one represents the integral glow. Also, a spectrometer whose receiving optics is movable together with the cameras is available as a diagnostic means. Several microparticles manipulation techniques are implemented in PK-4, starting from simple discharge current modulation to using a powerful infrared laser exerting radiation pressure on microparticles. The experiment is going to be conducted on board of the International Space Station. The launch is scheduled to October 2014. Even before being launched into orbit, the PK-4 project already delivered lots of interesting scientific results, obtained in ground laboratory and parabolic flight experiments and numerical simulations. First of all, the kinetic model of the discharge was built and the discharge parameters, such as electron density and temperature, number density of metastable atoms were measured. Diagnostic methods are being further developed to be used on orbit. Then, the microscopic properties of the microparticles (i.e. their charge and forces acting on them) were determined using dynamic methods. Size dynamics (growth and etching) of microparticles in PK-4 discharges were studied. Collective plasma phenomena (such as e.g. dust-acoustic) waves were investigated. And, finally, the interdisciplinary experiments, making a link between the PK-4 plasmas and real condensed matter were conducted. Such phenomenon as electrorheology was successfully modelled with PK-4 complex plasmas in a parabolic flight. A review of the results and a roadmap for future orbital operations will be presented in this contribution.

  16. The hydrogen coma of Comet P/Halley observed in Lyman-alpha using sounding rockets

    NASA Technical Reports Server (NTRS)

    Mccoy, R. P.; Meier, R. R.; Keller, H. U.; Opal, C. B.; Carruthers, G. R.

    1992-01-01

    Hydrogen Lyman-alpha (121.6 nm) images of Comet P/Halley were obtained using sounding rockets launched from White Sands Missile Range on 24.5 February and 13.5 March 1986. The second rocket was launched 13 hours before the fly-by of the Giotto spacecraft. An electrographic camera on both flights provided Lyman-alpha images covering a 20 field of view with 3 arcmin resolution. The data from both flights have been compared with a time-dependent model of hydrogen kinetics. To match the measured isophote contours, hydrogen sources with velocity components of 8 km/s and 20 km/s (from OH and H2O respectively) as well as a low velocity component (about 2 km/s) are required. This low velocity component is thought to result from thermalization of fast hydrogen atoms within the collision zone, providing an important diagnostic of temperature and density near the nucleus. Hydrogen production rates of 3.8 x 10 exp 30/s and 1.7 x 10 exp 30/s have been obtained for the two observations.

  17. Experimental investigation of plasma relaxation using a compact coaxial magnetized plasma gun in a background plasma

    NASA Astrophysics Data System (ADS)

    Zhang, Yue; Lynn, Alan; Gilmore, Mark; Hsu, Scott; University of New Mexico Collaboration; Los Alamos National Laboratory Collaboration

    2013-10-01

    A compact coaxial plasma gun is employed for experimental studies of plasma relaxation in a low density background plasma. Experiments are being conducted in the linear HelCat device at UNM. These studies will advance the knowledge of basic plasma physics in the areas of magnetic relaxation and space and astrophysical plasmas, including the evolution of active galactic jets/radio lobes within the intergalactic medium. The gun is powered by a 120pF ignitron-switched capacitor bank which is operated in a range of 5-10 kV and ~100 kA. Multiple diagnostics are employed to investigate plasma relaxation process. Magnetized Argon plasma bubbles with velocities ~1.2Cs and densities ~1020 m-3 have been achieved. Different distinct regimes of operation with qualitatively different dynamics are identified by fast CCD camera images, with the parameter determining the operation regime. Additionally, a B-dot probe array is employed to measure the spatial toroidal and poloidal magnetic flux evolution to identify detached plasma bubble configurations. Experimental data and analysis will be presented.

  18. Cellular nonlinear networks for strike-point localization at JET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arena, P.; Fortuna, L.; Bruno, M.

    2005-11-15

    At JET, the potential of fast image processing for real-time purposes is thoroughly investigated. Particular attention is devoted to smart sensors based on system on chip technology. The data of the infrared cameras were processed with a chip implementing a cellular nonlinear network (CNN) structure so as to support and complement the magnetic diagnostics in the real-time localization of the strike-point position in the divertor. The circuit consists of two layers of complementary metal-oxide semiconductor components, the first being the sensor and the second implementing the actual CNN. This innovative hardware has made it possible to determine the position ofmore » the maximum thermal load with a time resolution of the order of 30 ms. Good congruency has been found with the measurement from the thermocouples in the divertor, proving the potential of the infrared data in locating the region of the maximum thermal load. The results are also confirmed by JET magnetic codes, both those used for the equilibrium reconstructions and those devoted to the identification of the plasma boundary.« less

  19. Automated 3D-Printed Unibody Immunoarray for Chemiluminescence Detection of Cancer Biomarker Proteins

    PubMed Central

    Tang, C. K.; Vaze, A.; Rusling, J. F.

    2017-01-01

    A low cost three-dimensional (3D) printed clear plastic microfluidic device was fabricated for fast, low cost automated protein detection. The unibody device features three reagent reservoirs, an efficient 3D network for passive mixing, and an optically transparent detection chamber housing a glass capture antibody array for measuring chemiluminescence output with a CCD camera. Sandwich type assays were built onto the glass arrays using a multi-labeled detection antibody-polyHRP (HRP = horseradish peroxidase). Total assay time was ~30 min in a complete automated assay employing a programmable syringe pump so that the protocol required minimal operator intervention. The device was used for multiplexed detection of prostate cancer biomarker proteins prostate specific antigen (PSA) and platelet factor 4 (PF-4). Detection limits of 0.5 pg mL−1 were achieved for these proteins in diluted serum with log dynamic ranges of four orders of magnitude. Good accuracy vs ELISA was validated by analyzing human serum samples. This prototype device holds good promise for further development as a point-of-care cancer diagnostics tool. PMID:28067370

  20. Colliding Laser-Produced Plasmas on LaPD

    NASA Astrophysics Data System (ADS)

    Collette, Andrew; Gekelman, Walter

    2008-11-01

    The expansion and interaction of dense plasmas in the presence of a magnetized background plasma is important in many astrophysical processes. We describe a series of experiments which involve the collision of two dense (initially n > 10^15cm-3) laser-produced plasmas within an ambient, highly magnetized background plasma at the UCLA Large Plasma Device facility. These plasmas form diamagnetic cavities in which a large fraction of the background field (600G) has been expelled. Fast (3ns) camera observations of this experiment recorded complicated structures, including coherent corrugated structures on the bubble surfaces. The data hint at the presence of turbulence in the interaction. In order to directly investigate the evolution of the magnetic field, we developed a novel diagnostic system composed of small (1-mm) 3-axis differential magnetic field probes, in conjunction with a vacuum ceramic motor system capable of sub-micron positioning accuracy. Using an ensemble of magnetic field data from fixed and movable probes, we calculate the cross-spectral function, from which the dominant modes and ultimately the dispersion relation of waves in this region may be deduced.

  1. Development of CCD Cameras for Soft X-ray Imaging at the National Ignition Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teruya, A. T.; Palmer, N. E.; Schneider, M. B.

    2013-09-01

    The Static X-Ray Imager (SXI) is a National Ignition Facility (NIF) diagnostic that uses a CCD camera to record time-integrated X-ray images of target features such as the laser entrance hole of hohlraums. SXI has two dedicated positioners on the NIF target chamber for viewing the target from above and below, and the X-ray energies of interest are 870 eV for the “soft” channel and 3 – 5 keV for the “hard” channels. The original cameras utilize a large format back-illuminated 2048 x 2048 CCD sensor with 24 micron pixels. Since the original sensor is no longer available, an effortmore » was recently undertaken to build replacement cameras with suitable new sensors. Three of the new cameras use a commercially available front-illuminated CCD of similar size to the original, which has adequate sensitivity for the hard X-ray channels but not for the soft. For sensitivity below 1 keV, Lawrence Livermore National Laboratory (LLNL) had additional CCDs back-thinned and converted to back-illumination for use in the other two new cameras. In this paper we describe the characteristics of the new cameras and present performance data (quantum efficiency, flat field, and dynamic range) for the front- and back-illuminated cameras, with comparisons to the original cameras.« less

  2. PRIMAS: a real-time 3D motion-analysis system

    NASA Astrophysics Data System (ADS)

    Sabel, Jan C.; van Veenendaal, Hans L. J.; Furnee, E. Hans

    1994-03-01

    The paper describes a CCD TV-camera-based system for real-time multicamera 2D detection of retro-reflective targets and software for accurate and fast 3D reconstruction. Applications of this system can be found in the fields of sports, biomechanics, rehabilitation research, and various other areas of science and industry. The new feature of real-time 3D opens an even broader perspective of application areas; animations in virtual reality are an interesting example. After presenting an overview of the hardware and the camera calibration method, the paper focuses on the real-time algorithms used for matching of the images and subsequent 3D reconstruction of marker positions. When using a calibrated setup of two cameras, it is now possible to track at least ten markers at 100 Hz. Limitations in the performance are determined by the visibility of the markers, which could be improved by adding a third camera.

  3. Optical Design of the Camera for Transiting Exoplanet Survey Satellite (TESS)

    NASA Technical Reports Server (NTRS)

    Chrisp, Michael; Clark, Kristin; Primeau, Brian; Dalpiaz, Michael; Lennon, Joseph

    2015-01-01

    The optical design of the wide field of view refractive camera, 34 degrees diagonal field, for the TESS payload is described. This fast f/1.4 cryogenic camera, operating at -75 C, has no vignetting for maximum light gathering within the size and weight constraints. Four of these cameras capture full frames of star images for photometric searches of planet crossings. The optical design evolution, from the initial Petzval design, took advantage of Forbes aspheres to develop a hybrid design form. This maximized the correction from the two aspherics resulting in a reduction of average spot size by sixty percent in the final design. An external long wavelength pass filter was replaced by an internal filter coating on a lens to save weight, and has been fabricated to meet the specifications. The stray light requirements were met by an extended lens hood baffle design, giving the necessary off-axis attenuation.

  4. Real-time Accurate Surface Reconstruction Pipeline for Vision Guided Planetary Exploration Using Unmanned Ground and Aerial Vehicles

    NASA Technical Reports Server (NTRS)

    Almeida, Eduardo DeBrito

    2012-01-01

    This report discusses work completed over the summer at the Jet Propulsion Laboratory (JPL), California Institute of Technology. A system is presented to guide ground or aerial unmanned robots using computer vision. The system performs accurate camera calibration, camera pose refinement and surface extraction from images collected by a camera mounted on the vehicle. The application motivating the research is planetary exploration and the vehicles are typically rovers or unmanned aerial vehicles. The information extracted from imagery is used primarily for navigation, as robot location is the same as the camera location and the surfaces represent the terrain that rovers traverse. The processed information must be very accurate and acquired very fast in order to be useful in practice. The main challenge being addressed by this project is to achieve high estimation accuracy and high computation speed simultaneously, a difficult task due to many technical reasons.

  5. Design and Development of Multi-Purpose CCD Camera System with Thermoelectric Cooling: Hardware

    NASA Astrophysics Data System (ADS)

    Kang, Y.-W.; Byun, Y. I.; Rhee, J. H.; Oh, S. H.; Kim, D. K.

    2007-12-01

    We designed and developed a multi-purpose CCD camera system for three kinds of CCDs; KAF-0401E(768×512), KAF-1602E(1536×1024), KAF-3200E(2184×1472) made by KODAK Co.. The system supports fast USB port as well as parallel port for data I/O and control signal. The packing is based on two stage circuit boards for size reduction and contains built-in filter wheel. Basic hardware components include clock pattern circuit, A/D conversion circuit, CCD data flow control circuit, and CCD temperature control unit. The CCD temperature can be controlled with accuracy of approximately 0.4° C in the max. range of temperature, Δ 33° C. This CCD camera system has with readout noise 6 e^{-}, and system gain 5 e^{-}/ADU. A total of 10 CCD camera systems were produced and our tests show that all of them show passable performance.

  6. Photodetectors for the Advanced Gamma-ray Imaging System (AGIS)

    NASA Astrophysics Data System (ADS)

    Wagner, Robert G.; Advanced Gamma-ray Imaging System AGIS Collaboration

    2010-03-01

    The Advanced Gamma-Ray Imaging System (AGIS) is a concept for the next generation very high energy gamma-ray observatory. Design goals include an order of magnitude better sensitivity, better angular resolution, and a lower energy threshold than existing Cherenkov telescopes. Each telescope is equipped with a camera that detects and records the Cherenkov-light flashes from air showers. The camera is comprised of a pixelated focal plane of blue sensitive and fast (nanosecond) photon detectors that detect the photon signal and convert it into an electrical one. Given the scale of AGIS, the camera must be reliable and cost effective. The Schwarzschild-Couder optical design yields a smaller plate scale than present-day Cherenkov telescopes, enabling the use of more compact, multi-pixel devices, including multianode photomultipliers or Geiger avalanche photodiodes. We present the conceptual design of the focal plane for the camera and results from testing candidate! focal plane sensors.

  7. Synthetic NPA diagnostic for energetic particles in JET plasmas

    NASA Astrophysics Data System (ADS)

    Varje, J.; Sirén, P.; Weisen, H.; Kurki-Suonio, T.; Äkäslompolo, S.; contributors, JET

    2017-11-01

    Neutral particle analysis (NPA) is one of the few methods for diagnosing fast ions inside a plasma by measuring neutral atom fluxes emitted due to charge exchange reactions. The JET tokamak features an NPA diagnostic which measures neutral atom fluxes and energy spectra simultaneously for hydrogen, deuterium and tritium species. A synthetic NPA diagnostic has been developed and used to interpret these measurements to diagnose energetic particles in JET plasmas with neutral beam injection (NBI) heating. The synthetic NPA diagnostic performs a Monte Carlo calculation of the neutral atom fluxes in a realistic geometry. The 4D fast ion distributions, representing NBI ions, were simulated using the Monte Carlo orbit-following code ASCOT. Neutral atom density profiles were calculated using the FRANTIC neutral code in the JINTRAC modelling suite. Additionally, for rapid analysis, a scan of neutral profiles was precalculated with FRANTIC for a range of typical plasma parameters. These were taken from the JETPEAK database, which includes a comprehensive set of data from the flat-top phases of nearly all discharges in recent JET campaigns. The synthetic diagnostic was applied to various JET plasmas in the recent hydrogen campaign where different hydrogen/deuterium mixtures and NBI configurations were used. The simulated neutral fluxes from the fast ion distributions were found to agree with the measured fluxes, reproducing the slowing-down profiles for different beam isotopes and energies and quantitatively estimating the fraction of hydrogen and deuterium fast ions.

  8. Characteristics of the Secondary Divertor on DIII-D

    NASA Astrophysics Data System (ADS)

    Watkins, J. G.; Lasnier, C. J.; Leonard, A. W.; Evans, T. E.; Pitts, R.; Stangeby, P. C.; Boedo, J. A.; Moyer, R. A.; Rudakov, D. L.

    2009-11-01

    In order to address a concern that the ITER secondary divertor strike plates may be insufficiently robust to handle the incident pulses of particles and energy from ELMs, we performed dedicated studies of the secondary divertor plasma and scrape-off layer (SOL). Detailed measurements of the ELM energy and particle deposition footprint on the secondary divertor target plates were made with a fast IR camera and Langmuir probes and SOL profile and transport measurements were made with reciprocating probes. The secondary divertor and SOL conditions depended on changes in the magnetic balance and the core plasma density. Larger density resulted in smaller ELMs and the magnetic balance affected how many ELM particles coupled to the secondary SOL and divertor. Particularly striking are the images from a new fast IR camera that resolve ELM heat pulses and show spiral patterns with multiple peaks during ELMs in the secondary divertor.

  9. An accurate automated technique for quasi-optics measurement of the microwave diagnostics for fusion plasma

    NASA Astrophysics Data System (ADS)

    Hu, Jianqiang; Liu, Ahdi; Zhou, Chu; Zhang, Xiaohui; Wang, Mingyuan; Zhang, Jin; Feng, Xi; Li, Hong; Xie, Jinlin; Liu, Wandong; Yu, Changxuan

    2017-08-01

    A new integrated technique for fast and accurate measurement of the quasi-optics, especially for the microwave/millimeter wave diagnostic systems of fusion plasma, has been developed. Using the LabVIEW-based comprehensive scanning system, we can realize not only automatic but also fast and accurate measurement, which will help to eliminate the effects of temperature drift and standing wave/multi-reflection. With the Matlab-based asymmetric two-dimensional Gaussian fitting method, all the desired parameters of the microwave beam can be obtained. This technique can be used in the design and testing of microwave diagnostic systems such as reflectometers and the electron cyclotron emission imaging diagnostic systems of the Experimental Advanced Superconducting Tokamak.

  10. Temporal Imaging CeBr3 Compton Camera: A New Concept for Nuclear Decommissioning and Nuclear Waste Management

    NASA Astrophysics Data System (ADS)

    Iltis, A.; Snoussi, H.; Magalhaes, L. Rodrigues de; Hmissi, M. Z.; Zafiarifety, C. Tata; Tadonkeng, G. Zeufack; Morel, C.

    2018-01-01

    During nuclear decommissioning or waste management operations, a camera that could make an image of the contamination field and identify and quantify the contaminants would be a great progress. Compton cameras have been proposed, but their limited efficiency for high energy gamma rays and their cost have severely limited their application. Our objective is to promote a Compton camera for the energy range (200 keV - 2 MeV) that uses fast scintillating crystals and a new concept for locating scintillation event: Temporal Imaging. Temporal Imaging uses monolithic plates of fast scintillators and measures photons time of arrival distribution in order to locate each gamma ray with a high precision in space (X,Y,Z), time (T) and energy (E). This provides a native estimation of the depth of interaction (Z) of every detected gamma ray. This also allows a time correction for the propagation time of scintillation photons inside the crystal, therefore resulting in excellent time resolution. The high temporal resolution of the system makes it possible to veto quite efficiently background by using narrow time coincidence (< 300 ps). It is also possible to reconstruct the direction of propagation of the photons inside the detector using timing constraints. The sensitivity of our system is better than 1 nSv/h in a 60 s acquisition with a 22Na source. The project TEMPORAL is funded by the ANDRA/PAI under the grant No. RTSCNADAA160019.

  11. Inferred UV Fluence Focal-Spot Profiles from Soft X-Ray Pinhole Camera Measurements on OMEGA

    NASA Astrophysics Data System (ADS)

    Theobald, W.; Sorce, C.; Epstein, R.; Keck, R. L.; Kellogg, C.; Kessler, T. J.; Kwiatkowski, J.; Marshall, F. J.; Seka, W.; Shvydky, A.; Stoeckl, C.

    2017-10-01

    The drive uniformity of OMEGA cryogenic implosions is affected by UV beamfluence variations on target, which require careful monitoring at full laser power. This is routinely performed with multiple pinhole cameras equipped with charge-injection devices (CID's) that record the x-ray emission in the 3- to 7-keV photon energy range from an Au-coated target. The technique relies on the knowledge of the relation between x-ray fluence Fx and UV fluence FUV ,Fx FUVγ , with a measured γ = 3.42 for the CID-based diagnostic and 1-ns laser pulse. It is demonstrated here that using a back-thinned charge-coupled-device camera with softer filtration for x-rays with photon energies <2 keV and well calibrated pinhole provides a lower γ 2 and a larger dynamic range in the measured UV fluence. Inferred UV fluence profiles were measured for 100-ps and 1-ns laser pulses and were compared to directly measured profiles from a UV equivalent-target-plane diagnostic. Good agreement between both techniques is reported for selected beams. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.

  12. Time-resolved soft-x-ray studies of energy transport in layered and planar laser-driven targets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stradling, G.L.

    New low-energy x-ray diagnostic techniques are used to explore energy-transport processes in laser heated plasmas. Streak cameras are used to provide 15-psec time-resolution measurements of subkeV x-ray emission. A very thin (50 ..mu..g/cm/sup 2/) carbon substrate provides a low-energy x-ray transparent window to the transmission photocathode of this soft x-ray streak camera. Active differential vacuum pumping of the instrument is required. The use of high-sensitivity, low secondary-electron energy-spread CsI photocathodes in x-ray streak cameras is also described. Significant increases in sensitivity with only a small and intermittant decrease in dynamic range were observed. These coherent, complementary advances in subkeV, time-resolvedmore » x-ray diagnostic capability are applied to energy-transport investigations of 1.06-..mu..m laser plasmas. Both solid disk targets of a variety of Z's as well as Be-on-Al layered-disk targets were irradiated with 700-psec laser pulses of selected intensity between 3 x 10/sup 14/ W/cm/sup 2/ and 1 x 10/sup 15/ W/cm/sup 2/.« less

  13. A Fast and Robust Extrinsic Calibration for RGB-D Camera Networks.

    PubMed

    Su, Po-Chang; Shen, Ju; Xu, Wanxin; Cheung, Sen-Ching S; Luo, Ying

    2018-01-15

    From object tracking to 3D reconstruction, RGB-Depth (RGB-D) camera networks play an increasingly important role in many vision and graphics applications. Practical applications often use sparsely-placed cameras to maximize visibility, while using as few cameras as possible to minimize cost. In general, it is challenging to calibrate sparse camera networks due to the lack of shared scene features across different camera views. In this paper, we propose a novel algorithm that can accurately and rapidly calibrate the geometric relationships across an arbitrary number of RGB-D cameras on a network. Our work has a number of novel features. First, to cope with the wide separation between different cameras, we establish view correspondences by using a spherical calibration object. We show that this approach outperforms other techniques based on planar calibration objects. Second, instead of modeling camera extrinsic calibration using rigid transformation, which is optimal only for pinhole cameras, we systematically test different view transformation functions including rigid transformation, polynomial transformation and manifold regression to determine the most robust mapping that generalizes well to unseen data. Third, we reformulate the celebrated bundle adjustment procedure to minimize the global 3D reprojection error so as to fine-tune the initial estimates. Finally, our scalable client-server architecture is computationally efficient: the calibration of a five-camera system, including data capture, can be done in minutes using only commodity PCs. Our proposed framework is compared with other state-of-the-arts systems using both quantitative measurements and visual alignment results of the merged point clouds.

  14. A Fast and Robust Extrinsic Calibration for RGB-D Camera Networks †

    PubMed Central

    Shen, Ju; Xu, Wanxin; Luo, Ying

    2018-01-01

    From object tracking to 3D reconstruction, RGB-Depth (RGB-D) camera networks play an increasingly important role in many vision and graphics applications. Practical applications often use sparsely-placed cameras to maximize visibility, while using as few cameras as possible to minimize cost. In general, it is challenging to calibrate sparse camera networks due to the lack of shared scene features across different camera views. In this paper, we propose a novel algorithm that can accurately and rapidly calibrate the geometric relationships across an arbitrary number of RGB-D cameras on a network. Our work has a number of novel features. First, to cope with the wide separation between different cameras, we establish view correspondences by using a spherical calibration object. We show that this approach outperforms other techniques based on planar calibration objects. Second, instead of modeling camera extrinsic calibration using rigid transformation, which is optimal only for pinhole cameras, we systematically test different view transformation functions including rigid transformation, polynomial transformation and manifold regression to determine the most robust mapping that generalizes well to unseen data. Third, we reformulate the celebrated bundle adjustment procedure to minimize the global 3D reprojection error so as to fine-tune the initial estimates. Finally, our scalable client-server architecture is computationally efficient: the calibration of a five-camera system, including data capture, can be done in minutes using only commodity PCs. Our proposed framework is compared with other state-of-the-arts systems using both quantitative measurements and visual alignment results of the merged point clouds. PMID:29342968

  15. Breast-specific gamma camera imaging with 99mTc-MIBI has better diagnostic performance than magnetic resonance imaging in breast cancer patients: A meta-analysis.

    PubMed

    Zhang, Aimi; Li, Panli; Liu, Qiufang; Song, Shaoli

    2017-01-01

    This study aimed to evaluate the diagnostic role of breast-specific gamma camera imaging (BSGI) with technetium-99m-methoxy isobutyl isonitrile ( 99m Tc-MIBI) and magnetic resonance imaging (MRI) in patients with breast cancer through a meta-analysis. Three reviewers searched articles published in medical journals before June 2016 in MEDLINE, EMBASE and Springer Databases; the references listed in original articles were also retrieved. We used the quality assessment of diagnostic accuracy studies (QUADAS) tool to assess the quality of the included studies. Heterogeneity, pooled sensitivity and specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio (DOR) and summary receiver operating characteristic (SROC) curves were calculated by Meta-DiSc software to estimate the diagnostic performance of BSGI and MRI. Ten studies with 517 patients were included after meeting the inclusion criteria. We did a subgroup analysis of the same data type. The pooled sensitivities of BSGI and MRI were: 0.84 (95% CI, 0.79-0.88) and 0.89 (95% CI, 0.84-0.92) respectively, and the pooled specificities of BSGI and MRI were: 0.82 (95% CI, 0.74-0.88) and 0.39 (95% CI, 0.30-0.49) respectively. The areas under the SROC curve of BSGI and MRI were 0.93 and 0.72 respectively. The results of our meta-analysis indicated that compared with MRI, BSGI has similar sensitivity, higher specificity, better diagnostic performance, and can be widely used in clinical practice.

  16. The Endockscope Using Next Generation Smartphones: "A Global Opportunity".

    PubMed

    Tse, Christina; Patel, Roshan M; Yoon, Renai; Okhunov, Zhamshid; Landman, Jaime; Clayman, Ralph V

    2018-06-02

    The Endockscope combines a smartphone, a battery powered flashlight and a fiberoptic cystoscope allowing for mobile videocystoscopy. We compared conventional videocystoscopy to the Endockscope paired with next generation smartphones in an ex-vivo porcine bladder model to evaluate its image quality. The Endockscope consists of a three-dimensional (3D) printed attachment that connects a smartphone to a flexible fiberoptic cystoscope plus a 1000 lumen light-emitting diode (LED) cordless light source. Video recordings of porcine cystoscopy with a fiberoptic flexible cystoscope (Storz) were captured for each mobile device (iPhone 6, iPhone 6S, iPhone 7, Samsung S8, and Google Pixel) and for the high-definition H3-Z versatile camera (HD) set-up with both the LED light source and the xenon light (XL) source. Eleven faculty urologists, blinded to the modality used, evaluated each video for image quality/resolution, brightness, color quality, sharpness, overall quality, and acceptability for diagnostic use. When comparing the Endockscope coupled to an Galaxy S8, iPhone 7, and iPhone 6S with the LED portable light source to the HD camera with XL, there were no statistically significant differences in any metric. 82% and 55% of evaluators considered the iPhone 7 + LED light source and iPhone 6S + LED light, respectively, appropriate for diagnostic purposes as compared to 100% who considered the HD camera with XL appropriate. The iPhone 6 and Google Pixel coupled with the LED source were both inferior to the HD camera with XL in all metrics. The Endockscope system with a LED light source when coupled with either an iPhone 7 or Samsung S8 (total cost: $750) is comparable to conventional videocystoscopy with a standard camera and XL light source (total cost: $45,000).

  17. A compact multichannel spectrometer for Thomson scatteringa)

    NASA Astrophysics Data System (ADS)

    Schoenbeck, N. L.; Schlossberg, D. J.; Dowd, A. S.; Fonck, R. J.; Winz, G. R.

    2012-10-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of Te < 100 eV are achieved by a 2971 l/mm VPH grating and measurements Te > 100 eV by a 2072 l/mm VPH grating. The spectrometer uses a fast-gated (˜2 ns) ICCD camera for detection. A Gen III image intensifier provides ˜45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  18. A compact multichannel spectrometer for Thomson scattering.

    PubMed

    Schoenbeck, N L; Schlossberg, D J; Dowd, A S; Fonck, R J; Winz, G R

    2012-10-01

    The availability of high-efficiency volume phase holographic (VPH) gratings and intensified CCD (ICCD) cameras have motivated a simplified, compact spectrometer for Thomson scattering detection. Measurements of T(e) < 100 eV are achieved by a 2971 l∕mm VPH grating and measurements T(e) > 100 eV by a 2072 l∕mm VPH grating. The spectrometer uses a fast-gated (~2 ns) ICCD camera for detection. A Gen III image intensifier provides ~45% quantum efficiency in the visible region. The total read noise of the image is reduced by on-chip binning of the CCD to match the 8 spatial channels and the 10 spectral bins on the camera. Three spectrometers provide a minimum of 12 spatial channels and 12 channels for background subtraction.

  19. Real-Time Visualization of Tissue Ischemia

    NASA Technical Reports Server (NTRS)

    Bearman, Gregory H. (Inventor); Chrien, Thomas D. (Inventor); Eastwood, Michael L. (Inventor)

    2000-01-01

    A real-time display of tissue ischemia which comprises three CCD video cameras, each with a narrow bandwidth filter at the correct wavelength is discussed. The cameras simultaneously view an area of tissue suspected of having ischemic areas through beamsplitters. The output from each camera is adjusted to give the correct signal intensity for combining with, the others into an image for display. If necessary a digital signal processor (DSP) can implement algorithms for image enhancement prior to display. Current DSP engines are fast enough to give real-time display. Measurement at three, wavelengths, combined into a real-time Red-Green-Blue (RGB) video display with a digital signal processing (DSP) board to implement image algorithms, provides direct visualization of ischemic areas.

  20. End-on soft x ray imaging of Field-Reversed Configurations (FRCs) on the Field-Reversal-C (FRX-C)/Large Scale Modification (LSM) experiment

    NASA Astrophysics Data System (ADS)

    Taggart, D. P.; Gribble, R. J.; Bailey, A. D., III; Sugimoto, S.

    Recently, a prototype soft x ray pinhole camera was fielded on FRX-C/LSM at Los Alamos and TRX at Spectra Technology. The soft x ray FRC images obtained using this camera stand out in high contrast to their surroundings. It was particularly useful for studying the FRC during and shortly after formation when, at certain operating conditions, flute-like structures at the edge and internal structures of the FRC were observed which other diagnostics could not resolve. Building on this early experience, a new soft x ray pinhole camera was installed on FRX-C/LSM, which permits more rapid data acquisition and briefer exposures. It will be used to continue studying FRC formation and to look for internal structure later in time which could be a signature of instability. The initial operation of this camera is summarized.

  1. Soft X-ray streak camera for laser fusion applications

    NASA Astrophysics Data System (ADS)

    Stradling, G. L.

    1981-04-01

    The development and significance of the soft x-ray streak camera (SXRSC) in the context of inertial confinement fusion energy development is reviewed as well as laser fusion and laser fusion diagnostics. The SXRSC design criteria, the requirement for a subkilovolt x-ray transmitting window, and the resulting camera design are explained. Theory and design of reflector-filter pair combinations for three subkilovolt channels centered at 220 eV, 460 eV, and 620 eV are also presented. Calibration experiments are explained and data showing a dynamic range of 1000 and a sweep speed of 134 psec/mm are presented. Sensitivity modifications to the soft x-ray streak camera for a high-power target shot are described. A preliminary investigation, using a stepped cathode, of the thickness dependence of the gold photocathode response is discussed. Data from a typical Argus laser gold-disk target experiment are shown.

  2. Diagnostics of the dynamics of material damage by thermal shocks with the intensity possible in the ITER divertor

    NASA Astrophysics Data System (ADS)

    Vyacheslavov, L. N.; Arakcheev, A. S.; Bataev, I. A.; Burdakov, A. V.; Kandaurov, I. V.; Kasatov, A. A.; Kurkuchekov, V. V.; Popov, V. A.; Shoshin, A. A.; Skovorodin, D. I.; Trunev, Yu A.; Vasilyev, A. A.

    2018-03-01

    A novel BETA test facility (Beam of Electrons for materials Test Applications) was developed at the Budker Institute to study the erosion of materials directly during the impact of intense thermal shocks. A powerful (up to 7 MW) long pulse (100-300 μs) electron beam is applied for experimental simulation of fast transient heat loads with the intensity probable in the ITER divertor. The heat flux parameter on a target can be widely varied (FHF = 10-300 MW m-2 s0.5) from a value significantly below the melting threshold to a value much higher, within the area of about 1 cm2. The use of an electron beam to simulate the thermal impact on the material surface makes it possible to employ a variety of optical diagnostics for in situ observations of the dynamics of surface erosion processes during intense thermal shocks. These distinctive features make BETA a promising tool in the research of material surface erosion mechanisms and for experimental verification of various analytical and numerical models associated with these mechanisms. The first results obtained with this facility include fast (10 μs exposure) imaging of the heated target in the near-infrared range and in the reflected light of 532 nm continuous wave (CW) laser, visualization of ejected tungsten particles using fast ICCD and CCD cameras with the minimal exposure of 2 μs and 7 μs respectively. The dynamics of dust particles ejected from the heated surface is investigated using a multichannel recording of the light of 532 nm CW-laser scattered on the dust particles. The present paper describes the first results of use of two new in situ methods: continuous recording of light scattered from the tungsten surface and three-dimensional tracking of tungsten particles using three viewing angles. The first method makes it possible to observe the dynamics of development of roughness and cracking of the polished tungsten surface, which manifest themselves as two successive processes separated by a large time delay. The second method allows us to track dust particles ejected from the melt layer, and thus determine the time and place of particle ejection from the surface.

  3. Frequency of impaired glucose tolerance and diabetes mellitus in subjects with fasting blood glucose below 6.1 mmol/L (110 mg/dL).

    PubMed

    Khan, S H; Ijaz, A; Bokhari, S A Raza; Hanif, M S; Azam, N

    2013-02-01

    The diagnosis of diabetes mellitus by the available criteria is controversial and relies heavily on fasting glucose results. This cross-sectional study in 2010-2011 aimed to measure the frequency of impaired glucose tolerance and diabetes mellitus in 127 subjects having fasting blood glucose < 7.0 mmol/L and to measure the agreement between different standard diagnostic criteria. Subjects presenting to a laboratory for analysis of fasting blood glucose for excluding diabetes mellitus underwent a 2-hour 75 g oral glucose challenge. A total of 40.6% of subjects with fasting blood glucose from 5.6-6.0 mmol/L had abnormal glucose regulation on the basis ofthe gold standard glucose challenge. Agreement between American Diabetes Association and World Health Organization diagnostic criteria was only fair (kappa = 0.32). Abnormalities of glucose metabolism including impaired glucose tolerance and diabetes mellitus can exist at fasting blood glucose results < 6.1 mmol/L (110 mg/dL).

  4. Implosion dynamics and radiative properties of W planar wire arrays influenced by Al wires on University of Michigan's LTD generator

    NASA Astrophysics Data System (ADS)

    Safronova, A. S.; Kantsyrev, V. L.; Shlyaptseva, V. V.; Shrestha, I. K.; Butcher, C. J.; Stafford, A.; Campbell, P. C.; Miller, S.; Yager-Elorriaga, D. A.; Jordan, N. M.; McBride, R. D.; Gilgenbach, R. M.

    2017-10-01

    The results of new experiments with W Double Planar Wire Arrays (DPWA) at the University of Michigan's Linear Transformer Driver (LTD) generator are presented that are of particular importance for future work with wire arrays on 40-60 MA LTDs at SNL. A diagnostic set similar to the previous campaigns comprised filtered x-ray diodes, a Faraday cup, x-ray spectrometers and pinhole cameras, but had an ultra-fast 12-frame self-emission imaging system. Implosion and radiative characteristics of two DPWAs of the same mass (60 μg/cm) and geometry (two planes with 8 wires each at the distance of 6 mm and an inter-wire gap of 0.7 mm) with one plane of W wires and another either of W wires (1) or of Al wires (2) were compared in detail. The substantial differences between two cases are observed: 1) precursor formation and intense hard x-ray characteristic emission of W (``cold'' L lines) caused by electron beams; 2) no precursor, standing shocks at the W plane side that lasted up to a hundred of ns, fast ablation and implosion of Al wires, and suppression of hard x-ray ``cold'' L lines of W. In addition, the evolution of self-emission in a broad period of time up to 400 ns is analyzed for the first time. Research supported by NNSA under DOE Grant DE-NA0003047.

  5. High density plasmas and new diagnostics: An overview (invited).

    PubMed

    Celona, L; Gammino, S; Mascali, D

    2016-02-01

    One of the limiting factors for the full understanding of Electron Cyclotron Resonance Ion Sources (ECRISs) fundamental mechanisms consists of few types of diagnostic tools so far available for such compact machines. Microwave-to-plasma coupling optimisation, new methods of density overboost provided by plasma wave generation, and magnetostatic field tailoring for generating a proper electron energy distribution function, suitable for optimal ion beams formation, require diagnostic tools spanning across the entire electromagnetic spectrum from microwave interferometry to X-ray spectroscopy; these methods are going to be implemented including high resolution and spatially resolved X-ray spectroscopy made by quasi-optical methods (pin-hole cameras). The ion confinement optimisation also requires a complete control of cold electrons displacement, which can be performed by optical emission spectroscopy. Several diagnostic tools have been recently developed at INFN-LNS, including "volume-integrated" X-ray spectroscopy in low energy domain (2-30 keV, by using silicon drift detectors) or high energy regime (>30 keV, by using high purity germanium detectors). For the direct detection of the spatially resolved spectral distribution of X-rays produced by the electronic motion, a "pin-hole camera" has been developed also taking profit from previous experiences in the ECRIS field. The paper will give an overview of INFN-LNS strategy in terms of new microwave-to-plasma coupling schemes and advanced diagnostics supporting the design of new ion sources and for optimizing the performances of the existing ones, with the goal of a microwave-absorption oriented design of future machines.

  6. Visible camera imaging of plasmas in Proto-MPEX

    NASA Astrophysics Data System (ADS)

    Mosby, R.; Skeen, C.; Biewer, T. M.; Renfro, R.; Ray, H.; Shaw, G. C.

    2015-11-01

    The prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device being developed at Oak Ridge National Laboratory (ORNL). This machine plans to study plasma-material interaction (PMI) physics relevant to future fusion reactors. Measurements of plasma light emission will be made on Proto-MPEX using fast, visible framing cameras. The cameras utilize a global shutter, which allows a full frame image of the plasma to be captured and compared at multiple times during the plasma discharge. Typical exposure times are ~10-100 microseconds. The cameras are capable of capturing images at up to 18,000 frames per second (fps). However, the frame rate is strongly dependent on the size of the ``region of interest'' that is sampled. The maximum ROI corresponds to the full detector area, of ~1000x1000 pixels. The cameras have an internal gain, which controls the sensitivity of the 10-bit detector. The detector includes a Bayer filter, for ``true-color'' imaging of the plasma emission. This presentation will exmine the optimized camera settings for use on Proto-MPEX. This work was supported by the US. D.O.E. contract DE-AC05-00OR22725.

  7. Ingestible wireless capsules for enhanced diagnostic inspection of gastrointestinal tract

    NASA Astrophysics Data System (ADS)

    Rasouli, Mahdi; Kencana, Andy Prima; Huynh, Van An; Ting, Eng Kiat; Lai, Joshua Chong Yue; Wong, Kai Juan; Tan, Su Lim; Phee, Soo Jay

    2011-03-01

    Wireless capsule endoscopy has become a common procedure for diagnostic inspection of gastrointestinal tract. This method offers a less-invasive alternative to traditional endoscopy by eliminating uncomfortable procedures of the traditional endoscopy. Moreover, it provides the opportunity for exploring inaccessible areas of the small intestine. Current capsule endoscopes, however, move by peristalsis and are not capable of detailed and on-demand inspection of desired locations. Here, we propose and develop two wireless endoscopes with maneuverable vision systems to enhance diagnosis of gastrointestinal disorders. The vision systems in these capsules are equipped with mechanical actuators to adjust the position of the camera. This may help to cover larger areas of the digestive tract and investigate desired locations. The preliminary experimental results showed that the developed platform could successfully communicate with the external control unit via human body and adjust the position of camera to limited degrees.

  8. Preliminary Design of a Digital Holography PFC Erosion Diagnostic for MPEX

    NASA Astrophysics Data System (ADS)

    Thomas, C. E. (Tommy), Jr.; Biewer, T. M.; Shaw, G. C.; Baylor, L. R.; Combs, S. K.; Meitner, S. J.; Rapp, J.; Hillis, D. L.; Granstedt, E. M.; Majeski, R.; Kaita, R.

    2015-11-01

    Preliminary design of a Digital Holography (DH) in-situ Plasma Facing Component (PFC) erosion diagnostic to be used on the proto-MPEX/MPEX experiment is presented. Design trade-offs are discussed including the selection of CO2 laser frequencies and whether/where to use reflective or refractive optical components. The costs and benefits of using a high-speed (expensive) infrared (IR) camera or a lower speed (inexpensive) IR camera, and whether to use simultaneous or sequential acquisition of DH exposures for the dual wavelength system are also described. Expected layout, resolution, and noise figures will be discussed, along with resolution and noise data from previous work at ORNL and PPPL. Partial Support from USDOE Contract DE-AC02-09CH11466 and USDOE Grant DE-FG02-07ER84724 for previous Digital Holography work done at ORNL and PPPL is gratefully acknowledged.

  9. The clinical diagnostic accuracy of rapid detection of healthcare-associated bloodstream infection in intensive care using multipathogen real-time PCR technology

    PubMed Central

    Dunn, Graham; Chadwick, Paul; Young, Duncan; Bentley, Andrew; Carlson, Gordon; Warhurst, Geoffrey

    2011-01-01

    Background There is growing interest in the potential utility of real-time PCR in diagnosing bloodstream infection by detecting pathogen DNA in blood samples within a few hours. SeptiFast is a multipathogen probe-based real-time PCR system targeting ribosomal DNA sequences of bacteria and fungi. It detects and identifies the commonest pathogens causing bloodstream infection and has European regulatory approval. The SeptiFast pathogen panel is suited to identifying healthcare-associated bloodstream infection acquired during complex healthcare, and the authors report here the protocol for the first detailed health-technology assessment of multiplex real-time PCR in this setting. Methods/design A Phase III multicentre double-blinded diagnostic study will determine the clinical validity of SeptiFast for the rapid detection of healthcare-associated bloodstream infection, against the current service standard of microbiological culture, in an adequately sized population of critically ill adult patients. Results from SeptiFast and standard microbiological culture procedures in each patient will be compared at study conclusion and the metrics of clinical diagnostic accuracy of SeptiFast determined in this population setting. In addition, this study aims to assess further the preliminary evidence that the detection of pathogen DNA in the bloodstream using SeptiFast may have value in identifying the presence of infection elsewhere in the body. Furthermore, differences in circulating immune-inflammatory markers in patient groups differentiated by the presence/absence of culturable pathogens and pathogen DNA will help elucidate further the patho-physiology of infection developing in the critically ill. Ethics and dissemination Ethical approval has been granted by the North West 6 Research Ethics Committee (09/H1003/109). Based on the results of this first non-commercial study, independent recommendations will be made to The Department of Health (open-access health technology assessment report) as to whether SeptiFast has sufficient clinical diagnostic accuracy to move forward to efficacy testing during the provision of routine clinical care. PMID:22021785

  10. Design of multichord Hα detector arrays for the U-3M torsatron and identification of rotating plasma perturbations

    NASA Astrophysics Data System (ADS)

    Dreval, M. B.; Shapoval, A. M.; Ozherelyev, F. I.; Makhov, M. M.

    2016-07-01

    An Hα camera has been designed and installed in the U-3M torsatron for spatially and temporally resolved measurements. This device provides fast measurements of the emission brightness profile in the noisy environment of the radio frequency (RF) heated plasma. Unusual topology of diagnostics and the data acquisition system are applied. All the system components, including digitizers, are assembled in a single unit. It allows the suppression of a low-frequency electromagnetic interference by eliminating the ground loops. And the suppression of RF noises is achieved by eliminating the signal interface cables and digital interface cables in the design. The Wi-Fi interface is used to prevent a ground loop in the data transfer stage. The achieved sensitivity of our diagnostics is high enough for measuring the Hα emission from the low-density (ne ≈ (1-2)ṡ1010 cm-3) plasma with a temporal resolution of about 20 μs in the noisy environment. Different types of Hα emission fluctuations within the frequency range of 1-5 kHz and poloidal mode numbers m = 0 and m = 5 have been observed in U-3M. A simple technique of the line-of-sight data analysis, based on the U-3M magnetic surface asymmetry, is proposed and used for the spatial localization of the rotating mode and for the determination of mode numbers and its poloidal rotation direction using a single Hα array.

  11. Neutron Imaging Camera

    NASA Technical Reports Server (NTRS)

    Hunter, Stanley; deNolfo, G. A.; Barbier, L. M.; Link, J. T.; Son, S.; Floyd, S. R.; Guardala, N.; Skopec, M.; Stark, B.

    2008-01-01

    The Neutron Imaging Camera (NIC) is based on the Three-dimensional Track Imager (3DTI) technology developed at GSFC for gamma-ray astrophysics applications. The 3-DTI, a large volume time-projection chamber, provides accurate, approximately 0.4 mm resolution, 3-D tracking of charged particles. The incident direction of fast neutrons, En > 0.5 MeV, are reconstructed from the momenta and energies of the proton and triton fragments resulting from (sup 3)He(n,p) (sup 3)H interactions in the 3-DTI volume. The performance of the NIC from laboratory and accelerator tests is presented.

  12. Results from E ∥B Neutral Particle Analyzer and Calibration Ion Beam System on C-2U

    NASA Astrophysics Data System (ADS)

    Clary, Ryan; Roquemore, A.; Kolmogorov, A.; Ivanov, A.; Korepanov, S.; Magee, R.; Medley, S.; Smirnov, A.; Tiunov, M.; TAE Team

    2015-11-01

    C-2U is a a high-confinement, advanced beam driven FRC which aims to sustain the configuration for > 5 ms, in excess of typical MHD and fast particle instability times, as well as fast particle slowing down times. Fast particle dynamics are critical to C-2U performance and several diagnostics have been deployed to characterize the fast particle population, including neutron and proton detectors, an electrostatic neutral particle analyzer, and neutral particle bolometers. To increase our understanding of fast particle behavior and supplement existing diagnostics an E ∥B NPA was acquired from PPPL which simultaneously measures H0 and D0 flux between 2 and 22 keV with high energy resolution. In addition, a small, high purity, ion beam system has been constructed and tested to calibrate absolutely fast particle detectors. Here we report results of measurements from the E ∥B analyzer on C-2U and inferred fast particle behavior, as well as the status of the calibration ion beam system.

  13. In-vessel calibration of the imaging diagnostics for the real-time protection of the JET ITER-like wall.

    PubMed

    Huber, V; Huber, A; Kinna, D; Balboa, I; Collins, S; Conway, N; Drewelow, P; Maggi, C F; Matthews, G F; Meigs, A G; Mertens, Ph; Price, M; Sergienko, G; Silburn, S; Wynn, A; Zastrow, K-D

    2016-11-01

    The in situ absolute calibration of the JET real-time protection imaging system has been performed for the first time by means of radiometric light source placed inside the JET vessel and operated by remote handling. High accuracy of the calibration is confirmed by cross-validation of the near infrared (NIR) cameras against each other, with thermal IR cameras, and with the beryllium evaporator, which lead to successful protection of the JET first wall during the last campaign. The operation temperature ranges of NIR protection cameras for the materials used on JET are Be 650-1600 °C, W coating 600-1320 °C, and W 650-1500 °C.

  14. Improving the off-axis spatial resolution and dynamic range of the NIF X-ray streak cameras (invited)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacPhee, A. G., E-mail: macphee2@llnl.gov; Hatch, B. W.; Bell, P. M.

    2016-11-15

    We report simulations and experiments that demonstrate an increase in spatial resolution of the NIF core diagnostic x-ray streak cameras by at least a factor of two, especially off axis. A design was achieved by using a corrector electron optic to flatten the field curvature at the detector plane and corroborated by measurement. In addition, particle in cell simulations were performed to identify the regions in the streak camera that contribute the most to space charge blurring. These simulations provide a tool for convolving synthetic pre-shot spectra with the instrument function so signal levels can be set to maximize dynamicmore » range for the relevant part of the streak record.« less

  15. In-vessel calibration of the imaging diagnostics for the real-time protection of the JET ITER-like wall

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huber, V., E-mail: V.Huber@fz-juelich.de; Huber, A.; Mertens, Ph.

    The in situ absolute calibration of the JET real-time protection imaging system has been performed for the first time by means of radiometric light source placed inside the JET vessel and operated by remote handling. High accuracy of the calibration is confirmed by cross-validation of the near infrared (NIR) cameras against each other, with thermal IR cameras, and with the beryllium evaporator, which lead to successful protection of the JET first wall during the last campaign. The operation temperature ranges of NIR protection cameras for the materials used on JET are Be 650-1600 °C, W coating 600-1320 °C, and W 650-1500 °C.

  16. Improving the off-axis spatial resolution and dynamic range of the NIF X-ray streak cameras (invited).

    PubMed

    MacPhee, A G; Dymoke-Bradshaw, A K L; Hares, J D; Hassett, J; Hatch, B W; Meadowcroft, A L; Bell, P M; Bradley, D K; Datte, P S; Landen, O L; Palmer, N E; Piston, K W; Rekow, V V; Hilsabeck, T J; Kilkenny, J D

    2016-11-01

    We report simulations and experiments that demonstrate an increase in spatial resolution of the NIF core diagnostic x-ray streak cameras by at least a factor of two, especially off axis. A design was achieved by using a corrector electron optic to flatten the field curvature at the detector plane and corroborated by measurement. In addition, particle in cell simulations were performed to identify the regions in the streak camera that contribute the most to space charge blurring. These simulations provide a tool for convolving synthetic pre-shot spectra with the instrument function so signal levels can be set to maximize dynamic range for the relevant part of the streak record.

  17. Application of single-image camera calibration for ultrasound augmented laparoscopic visualization

    NASA Astrophysics Data System (ADS)

    Liu, Xinyang; Su, He; Kang, Sukryool; Kane, Timothy D.; Shekhar, Raj

    2015-03-01

    Accurate calibration of laparoscopic cameras is essential for enabling many surgical visualization and navigation technologies such as the ultrasound-augmented visualization system that we have developed for laparoscopic surgery. In addition to accuracy and robustness, there is a practical need for a fast and easy camera calibration method that can be performed on demand in the operating room (OR). Conventional camera calibration methods are not suitable for the OR use because they are lengthy and tedious. They require acquisition of multiple images of a target pattern in its entirety to produce satisfactory result. In this work, we evaluated the performance of a single-image camera calibration tool (rdCalib; Percieve3D, Coimbra, Portugal) featuring automatic detection of corner points in the image, whether partial or complete, of a custom target pattern. Intrinsic camera parameters of a 5-mm and a 10-mm standard Stryker® laparoscopes obtained using rdCalib and the well-accepted OpenCV camera calibration method were compared. Target registration error (TRE) as a measure of camera calibration accuracy for our optical tracking-based AR system was also compared between the two calibration methods. Based on our experiments, the single-image camera calibration yields consistent and accurate results (mean TRE = 1.18 ± 0.35 mm for the 5-mm scope and mean TRE = 1.13 ± 0.32 mm for the 10-mm scope), which are comparable to the results obtained using the OpenCV method with 30 images. The new single-image camera calibration method is promising to be applied to our augmented reality visualization system for laparoscopic surgery.

  18. Application of single-image camera calibration for ultrasound augmented laparoscopic visualization

    PubMed Central

    Liu, Xinyang; Su, He; Kang, Sukryool; Kane, Timothy D.; Shekhar, Raj

    2017-01-01

    Accurate calibration of laparoscopic cameras is essential for enabling many surgical visualization and navigation technologies such as the ultrasound-augmented visualization system that we have developed for laparoscopic surgery. In addition to accuracy and robustness, there is a practical need for a fast and easy camera calibration method that can be performed on demand in the operating room (OR). Conventional camera calibration methods are not suitable for the OR use because they are lengthy and tedious. They require acquisition of multiple images of a target pattern in its entirety to produce satisfactory result. In this work, we evaluated the performance of a single-image camera calibration tool (rdCalib; Percieve3D, Coimbra, Portugal) featuring automatic detection of corner points in the image, whether partial or complete, of a custom target pattern. Intrinsic camera parameters of a 5-mm and a 10-mm standard Stryker® laparoscopes obtained using rdCalib and the well-accepted OpenCV camera calibration method were compared. Target registration error (TRE) as a measure of camera calibration accuracy for our optical tracking-based AR system was also compared between the two calibration methods. Based on our experiments, the single-image camera calibration yields consistent and accurate results (mean TRE = 1.18 ± 0.35 mm for the 5-mm scope and mean TRE = 1.13 ± 0.32 mm for the 10-mm scope), which are comparable to the results obtained using the OpenCV method with 30 images. The new single-image camera calibration method is promising to be applied to our augmented reality visualization system for laparoscopic surgery. PMID:28943703

  19. Application of single-image camera calibration for ultrasound augmented laparoscopic visualization.

    PubMed

    Liu, Xinyang; Su, He; Kang, Sukryool; Kane, Timothy D; Shekhar, Raj

    2015-03-01

    Accurate calibration of laparoscopic cameras is essential for enabling many surgical visualization and navigation technologies such as the ultrasound-augmented visualization system that we have developed for laparoscopic surgery. In addition to accuracy and robustness, there is a practical need for a fast and easy camera calibration method that can be performed on demand in the operating room (OR). Conventional camera calibration methods are not suitable for the OR use because they are lengthy and tedious. They require acquisition of multiple images of a target pattern in its entirety to produce satisfactory result. In this work, we evaluated the performance of a single-image camera calibration tool ( rdCalib ; Percieve3D, Coimbra, Portugal) featuring automatic detection of corner points in the image, whether partial or complete, of a custom target pattern. Intrinsic camera parameters of a 5-mm and a 10-mm standard Stryker ® laparoscopes obtained using rdCalib and the well-accepted OpenCV camera calibration method were compared. Target registration error (TRE) as a measure of camera calibration accuracy for our optical tracking-based AR system was also compared between the two calibration methods. Based on our experiments, the single-image camera calibration yields consistent and accurate results (mean TRE = 1.18 ± 0.35 mm for the 5-mm scope and mean TRE = 1.13 ± 0.32 mm for the 10-mm scope), which are comparable to the results obtained using the OpenCV method with 30 images. The new single-image camera calibration method is promising to be applied to our augmented reality visualization system for laparoscopic surgery.

  20. AO WFS detector developments at ESO to prepare for the E-ELT

    NASA Astrophysics Data System (ADS)

    Downing, Mark; Casali, Mark; Finger, Gert; Lewis, Steffan; Marchetti, Enrico; Mehrgan, Leander; Ramsay, Suzanne; Reyes, Javier

    2016-07-01

    ESO has a very active on-going AO WFS detector development program to not only meet the needs of the current crop of instruments for the VLT, but also has been actively involved in gathering requirements, planning, and developing detectors and controllers/cameras for the instruments in design and being proposed for the E-ELT. This paper provides an overall summary of the AO WFS Detector requirements of the E-ELT instruments currently in design and telescope focal units. This is followed by a description of the many interesting detector, controller, and camera developments underway at ESO to meet these needs; a) the rationale behind and plan to upgrade the 240x240 pixels, 2000fps, "zero noise", L3Vision CCD220 sensor based AONGC camera; b) status of the LGSD/NGSD High QE, 3e- RoN, fast 700fps, 1760x1680 pixels, Visible CMOS Imager and camera development; c) status of and development plans for the Selex SAPHIRA NIR eAPD and controller. Most of the instruments and detector/camera developments are described in more detail in other papers at this conference.

  1. Motionless active depth from defocus system using smart optics for camera autofocus applications

    NASA Astrophysics Data System (ADS)

    Amin, M. Junaid; Riza, Nabeel A.

    2016-04-01

    This paper describes a motionless active Depth from Defocus (DFD) system design suited for long working range camera autofocus applications. The design consists of an active illumination module that projects a scene illuminating coherent conditioned optical radiation pattern which maintains its sharpness over multiple axial distances allowing an increased DFD working distance range. The imager module of the system responsible for the actual DFD operation deploys an electronically controlled variable focus lens (ECVFL) as a smart optic to enable a motionless imager design capable of effective DFD operation. An experimental demonstration is conducted in the laboratory which compares the effectiveness of the coherent conditioned radiation module versus a conventional incoherent active light source, and demonstrates the applicability of the presented motionless DFD imager design. The fast response and no-moving-parts features of the DFD imager design are especially suited for camera scenarios where mechanical motion of lenses to achieve autofocus action is challenging, for example, in the tiny camera housings in smartphones and tablets. Applications for the proposed system include autofocus in modern day digital cameras.

  2. Non-invasive diagnostics of ion beams in strong toroidal magnetic fields with standard CMOS cameras

    NASA Astrophysics Data System (ADS)

    Ates, Adem; Ates, Yakup; Niebuhr, Heiko; Ratzinger, Ulrich

    2018-01-01

    A superconducting Figure-8 stellarator type magnetostatic Storage Ring (F8SR) is under investigation at the Institute for Applied Physics (IAP) at Goethe University Frankfurt. Besides numerical simulations on an optimized design for beam transport and injection a scaled down (0.6T) experiment with two 30°toroidal magnets is set up for further investigations. A great challenge is the development of a non-destructive, magnetically insensitive and flexible detector for local investigations of an ion beam propagating through the toroidal magnetostatic field. This paper introduces a new way of beam path measurement by residual gas monitoring. It uses a single board camera connected to a standard single board computer by a camera serial interface all placed inside the vacuum chamber. First experiments with one camera were done and in a next step two under 90 degree arranged cameras were installed. With the help of the two cameras which are moveable along the beam pipe the theoretical predictions are experimentally verified successfully. Previous experimental results have been confirmed. The transport of H+ and H2+ ion beams with energies of 7 keV and at beam currents of about 1 mA is investigated successfully.

  3. Bacterial contamination monitor

    NASA Technical Reports Server (NTRS)

    Rich, E.; Macleod, N. H.

    1973-01-01

    Economical, simple, and fast method uses apparatus which detects bacteria by photography. Apparatus contains camera, film assembly, calibrated light bulb, opaque plastic plate with built-in reflecting surface and transparent window section, opaque slide, plate with chemical packages, and cover containing roller attached to handle.

  4. Comparison of myocardial perfusion imaging between the new high-speed gamma camera and the standard anger camera.

    PubMed

    Tanaka, Hirokazu; Chikamori, Taishiro; Hida, Satoshi; Uchida, Kenji; Igarashi, Yuko; Yokoyama, Tsuyoshi; Takahashi, Masaki; Shiba, Chie; Yoshimura, Mana; Tokuuye, Koichi; Yamashina, Akira

    2013-01-01

    Cadmium-zinc-telluride (CZT) solid-state detectors have been recently introduced into the field of myocardial perfusion imaging. The aim of this study was to prospectively compare the diagnostic performance of the CZT high-speed gamma camera (Discovery NM 530c) with that of the standard 3-head gamma camera in the same group of patients. The study group consisted of 150 consecutive patients who underwent a 1-day stress-rest (99m)Tc-sestamibi or tetrofosmin imaging protocol. Image acquisition was performed first on a standard gamma camera with a 15-min scan time each for stress and for rest. All scans were immediately repeated on a CZT camera with a 5-min scan time for stress and a 3-min scan time for rest, using list mode. The correlations between the CZT camera and the standard camera for perfusion and function analyses were strong within narrow Bland-Altman limits of agreement. Using list mode analysis, image quality for stress was rated as good or excellent in 97% of the 3-min scans, and in 100% of the ≥4-min scans. For CZT scans at rest, similarly, image quality was rated as good or excellent in 94% of the 1-min scans, and in 100% of the ≥2-min scans. The novel CZT camera provides excellent image quality, which is equivalent to standard myocardial single-photon emission computed tomography, despite a short scan time of less than half of the standard time.

  5. Broadband Terahertz Computed Tomography Using a 5k-pixel Real-time THz Camera

    NASA Astrophysics Data System (ADS)

    Trichopoulos, Georgios C.; Sertel, Kubilay

    2015-07-01

    We present a novel THz computed tomography system that enables fast 3-dimensional imaging and spectroscopy in the 0.6-1.2 THz band. The system is based on a new real-time broadband THz camera that enables rapid acquisition of multiple cross-sectional images required in computed tomography. Tomographic reconstruction is achieved using digital images from the densely-packed large-format (80×64) focal plane array sensor located behind a hyper-hemispherical silicon lens. Each pixel of the sensor array consists of an 85 μm × 92 μm lithographically fabricated wideband dual-slot antenna, monolithically integrated with an ultra-fast diode tuned to operate in the 0.6-1.2 THz regime. Concurrently, optimum impedance matching was implemented for maximum pixel sensitivity, enabling 5 frames-per-second image acquisition speed. As such, the THz computed tomography system generates diffraction-limited resolution cross-section images as well as the three-dimensional models of various opaque and partially transparent objects. As an example, an over-the-counter vitamin supplement pill is imaged and its material composition is reconstructed. The new THz camera enables, for the first time, a practical application of THz computed tomography for non-destructive evaluation and biomedical imaging.

  6. Foreground extraction for moving RGBD cameras

    NASA Astrophysics Data System (ADS)

    Junejo, Imran N.; Ahmed, Naveed

    2017-02-01

    In this paper, we propose a simple method to perform foreground extraction for a moving RGBD camera. These cameras have now been available for quite some time. Their popularity is primarily due to their low cost and ease of availability. Although the field of foreground extraction or background subtraction has been explored by the computer vision researchers since a long time, the depth-based subtraction is relatively new and has not been extensively addressed as of yet. Most of the current methods make heavy use of geometric reconstruction, making the solutions quite restrictive. In this paper, we make a novel use RGB and RGBD data: from the RGB frame, we extract corner features (FAST) and then represent these features with the histogram of oriented gradients (HoG) descriptor. We train a non-linear SVM on these descriptors. During the test phase, we make used of the fact that the foreground object has distinct depth ordering with respect to the rest of the scene. That is, we use the positively classified FAST features on the test frame to initiate a region growing to obtain the accurate segmentation of the foreground object from just the RGBD data. We demonstrate the proposed method of a synthetic datasets, and demonstrate encouraging quantitative and qualitative results.

  7. Digital holographic interferometry applied to the investigation of ignition process.

    PubMed

    Pérez-Huerta, J S; Saucedo-Anaya, Tonatiuh; Moreno, I; Ariza-Flores, D; Saucedo-Orozco, B

    2017-06-12

    We use the digital holographic interferometry (DHI) technique to display the early ignition process for a butane-air mixture flame. Because such an event occurs in a short time (few milliseconds), a fast CCD camera is used to study the event. As more detail is required for monitoring the temporal evolution of the process, less light coming from the combustion is captured by the CCD camera, resulting in a deficient and underexposed image. Therefore, the CCD's direct observation of the combustion process is limited (down to 1000 frames per second). To overcome this drawback, we propose the use of DHI along with a high power laser in order to supply enough light to increase the speed capture, thus improving the visualization of the phenomenon in the initial moments. An experimental optical setup based on DHI is used to obtain a large sequence of phase maps that allows us to observe two transitory stages in the ignition process: a first explosion which slightly emits visible light, and a second stage induced by variations in temperature when the flame is emerging. While the last stage can be directly monitored by the CCD camera, the first stage is hardly detected by direct observation, and DHI clearly evidences this process. Furthermore, our method can be easily adapted for visualizing other types of fast processes.

  8. Characterization of fast deuterons involved in the production of fusion neutrons in a dense plasma focus

    NASA Astrophysics Data System (ADS)

    Kubes, P.; Paduch, M.; Sadowski, M. J.; Cikhardt, J.; Cikhardtova, B.; Klir, D.; Kravarik, J.; Munzar, V.; Rezac, K.; Zielinska, E.; Skladnik-Sadowska, E.; Szymaszek, A.; Tomaszewski, K.; Zaloga, D.

    2018-01-01

    This paper considers regions of a fast deuteron production in a correlation with an evolution of ordered structures inside a pinch column of a mega-ampere plasma focus discharge. Ion pinhole cameras equipped with plastic PM-355 track-detectors recorded fast deuterons escaping in the downstream and other directions (up to 60° to the z-axis). Time-integrated ion images made it possible to estimate sources of the deuteron acceleration at the known magnetic field and deuteron energy values. The images of the fast deuterons emitted in the solid angle ranging from 0° to 4° showed two forms: central spots and circular images. The spots of 1-2 cm in diameter were produced by deuterons from the central pinch regions. The circular-shaped images of a radius above 3 cm (or their parts) were formed by deuterons from the region surrounding the dense pinch column. The ion pinhole cameras placed at angles above 20° to the z-axis recorded the ion spots only, and the ring-images were missing. The central region of the deuteron acceleration could be associated mainly with plasmoids, and the circular images could be connected with ring-shaped regions of the radius corresponding to tops of the plasma lobules outside the dense pinch column. The deuteron tracks forming ring-shaped images of a smaller (0.5-1) cm radius could be produced by deflections of the fast deuterons, which were caused by a magnetic field inside the dense pinch column.

  9. Apparatus for recording emissions from a rapidly generated plasma from a single plasma producing event

    DOEpatents

    Tan, Tai Ho; Williams, Arthur H.

    1985-01-01

    An optical fiber-coupled detector visible streak camera plasma diagnostic apparatus. Arrays of optical fiber-coupled detectors are placed on the film plane of several types of particle, x-ray and visible spectrometers or directly in the path of the emissions to be measured and the output is imaged by a visible streak camera. Time and spatial dependence of the emission from plasmas generated from a single pulse of electromagnetic radiation or from a single particle beam burst can be recorded.

  10. Apparatus for recording emissions from a rapidly generated plasma from a single plasma producing event

    DOEpatents

    Tan, T.H.; Williams, A.H.

    An optical fiber-coupled detector visible streak camera plasma diagnostic apparatus. Arrays of optical fiber-coupled detectors are placed on the film plane of several types of particle, x-ray and visible spectrometers or directly in the path of the emissions to be measured and the output is imaged by a visible streak camera. Time and spatial dependence of the emission from plasma generated from a single pulse of electromagnetic radiation or from a single particle beam burst can be recorded.

  11. [Communication subsystem design of tele-screening system for diabetic retinopathy].

    PubMed

    Chen, Jian; Pan, Lin; Zheng, Shaohua; Yu, Lun

    2013-12-01

    A design scheme of a tele-screening system for diabetic retinopathy (DR) has been proposed, especially the communication subsystem. The scheme uses serial communication module consisting of ARM 7 microcontroller and relays to connect remote computer and fundus camera, and also uses C++ programming language based on MFC to design the communication software consisting of therapy and diagnostic information module, video/audio surveillance module and fundus camera control module. The scheme possesses universal property in some remote medical treatment systems which are similar to the system.

  12. A flexible, on-line magnetic spectrometer for ultra-intense laser produced fast electron measurement

    NASA Astrophysics Data System (ADS)

    Ge, Xulei; Yuan, Xiaohui; Yang, Su; Deng, Yanqing; Wei, Wenqing; Fang, Yuan; Gao, Jian; Liu, Feng; Chen, Min; Zhao, Li; Ma, Yanyun; Sheng, Zhengming; Zhang, Jie

    2018-04-01

    We have developed an on-line magnetic spectrometer to measure energy distributions of fast electrons generated from ultra-intense laser-solid interactions. The spectrometer consists of a sheet of plastic scintillator, a bundle of non-scintillating plastic fibers, and an sCMOS camera recording system. The design advantages include on-line capturing ability, versatility of detection arrangement, and resistance to harsh in-chamber environment. The validity of the instrument was tested experimentally. This spectrometer can be applied to the characterization of fast electron source for understanding fundamental laser-plasma interaction physics and to the optimization of high-repetition-rate laser-driven applications.

  13. Dual Processing and Diagnostic Errors

    ERIC Educational Resources Information Center

    Norman, Geoff

    2009-01-01

    In this paper, I review evidence from two theories in psychology relevant to diagnosis and diagnostic errors. "Dual Process" theories of thinking, frequently mentioned with respect to diagnostic error, propose that categorization decisions can be made with either a fast, unconscious, contextual process called System 1 or a slow, analytical,…

  14. Analysis of staged Z-pinch implosion trajectories from experiments on Zebra

    NASA Astrophysics Data System (ADS)

    Ross, Mike P.; Conti, F.; Darling, T. W.; Ruskov, E.; Valenzuela, J.; Wessel, F. J.; Beg, F.; Narkis, J.; Rahman, H. U.

    2017-10-01

    The Staged Z-pinch plasma confinement concept relies on compressing an annular liner of high-Z plasma onto a target plasma column of deuterium fuel. The interface between the liner and target is stable against the Magneto-Rayleigh-Taylor Instability, which leads to effective fuel compression and makes the concept interesting as a potential fusion reactor. The liner initiates as a neutral gas puff, while the target plasma is a partially ionized (Zeff < 10 percent column ejected from a coaxial plasma gun. The Zebra pulsed power generator (1 MA peak current, 100 ns rise time) provides the discharge that ionizes the liner and drives the Z-pinch implosion. Diverse diagnostics observe the 100-300 km/s implosions including silicon diodes, photo-conducting detectors (PCDs), laser shadowgraphy, an XUV framing camera, and a visible streak camera. The imaging diagnostics track instabilities smaller than 0.1 mm, and Z-pinch diameters below 2.5 mm are seen at peak compression. This poster correlates the data from these diagnostics to elucidate implosion behavior dependencies on liner gas, liner pressure, target pressure, and applied, axial-magnetic field. Funded by the Advanced Research Projects Agency - Energy, DE-AR0000569.

  15. Design of Belief Propagation Based on FPGA for the Multistereo CAFADIS Camera

    PubMed Central

    Magdaleno, Eduardo; Lüke, Jonás Philipp; Rodríguez, Manuel; Rodríguez-Ramos, José Manuel

    2010-01-01

    In this paper we describe a fast, specialized hardware implementation of the belief propagation algorithm for the CAFADIS camera, a new plenoptic sensor patented by the University of La Laguna. This camera captures the lightfield of the scene and can be used to find out at which depth each pixel is in focus. The algorithm has been designed for FPGA devices using VHDL. We propose a parallel and pipeline architecture to implement the algorithm without external memory. Although the BRAM resources of the device increase considerably, we can maintain real-time restrictions by using extremely high-performance signal processing capability through parallelism and by accessing several memories simultaneously. The quantifying results with 16 bit precision have shown that performances are really close to the original Matlab programmed algorithm. PMID:22163404

  16. Design of belief propagation based on FPGA for the multistereo CAFADIS camera.

    PubMed

    Magdaleno, Eduardo; Lüke, Jonás Philipp; Rodríguez, Manuel; Rodríguez-Ramos, José Manuel

    2010-01-01

    In this paper we describe a fast, specialized hardware implementation of the belief propagation algorithm for the CAFADIS camera, a new plenoptic sensor patented by the University of La Laguna. This camera captures the lightfield of the scene and can be used to find out at which depth each pixel is in focus. The algorithm has been designed for FPGA devices using VHDL. We propose a parallel and pipeline architecture to implement the algorithm without external memory. Although the BRAM resources of the device increase considerably, we can maintain real-time restrictions by using extremely high-performance signal processing capability through parallelism and by accessing several memories simultaneously. The quantifying results with 16 bit precision have shown that performances are really close to the original Matlab programmed algorithm.

  17. A data acquisition system for coincidence imaging using a conventional dual head gamma camera

    NASA Astrophysics Data System (ADS)

    Lewellen, T. K.; Miyaoka, R. S.; Jansen, F.; Kaplan, M. S.

    1997-06-01

    A low cost data acquisition system (DAS) was developed to acquire coincidence data from an unmodified General Electric Maxxus dual head scintillation camera. A high impedance pick-off circuit provides position and energy signals to the DAS without interfering with normal camera operation. The signals are pulse-clipped to reduce pileup effects. Coincidence is determined with fast timing signals derived from constant fraction discriminators. A charge-integrating FERA 16 channel ADC feeds position and energy data to two CAMAC FERA memories operated as ping-pong buffers. A Macintosh PowerPC running Labview controls the system and reads the CAMAC memories. A CAMAC 12-channel scaler records singles and coincidence rate data. The system dead-time is approximately 10% at a coincidence rate of 4.0 kHz.

  18. Large Area Field of View for Fast Temporal Resolution Astronomy

    NASA Astrophysics Data System (ADS)

    Covarrubias, Ricardo A.

    2018-01-01

    Scientific CMOS (sCMOS) technology is especially relevant for high temporal resolution astronomy combining high resolution, large field of view with very fast frame rates, without sacrificing ultra-low noise performance. Solar Astronomy, Near Earth Object detections, Space Debris Tracking, Transient Observations or Wavefront Sensing are among the many applications this technology can be utilized. Andor Technology is currently developing the next-generation, very large area sCMOS camera with an extremely low noise, rapid frame rates, high resolution and wide dynamic range.

  19. A Fast MEANSHIFT Algorithm-Based Target Tracking System

    PubMed Central

    Sun, Jian

    2012-01-01

    Tracking moving targets in complex scenes using an active video camera is a challenging task. Tracking accuracy and efficiency are two key yet generally incompatible aspects of a Target Tracking System (TTS). A compromise scheme will be studied in this paper. A fast mean-shift-based Target Tracking scheme is designed and realized, which is robust to partial occlusion and changes in object appearance. The physical simulation shows that the image signal processing speed is >50 frame/s. PMID:22969397

  20. A Fast Event Preprocessor and Sequencer for the Simbol-X Low Energy Detector

    NASA Astrophysics Data System (ADS)

    Schanz, T.; Tenzer, C.; Maier, D.; Kendziorra, E.; Santangelo, A.

    2009-05-01

    The Simbol-X Low Energy Detector (LED), a 128×128 pixel DEPFET (Depleted Field Effect Transistor) array, will be read out at a very high rate (8000 frames/second) and, therefore, requires a very fast on board electronics. We present an FPGA-based LED camera electronics consisting of an Event Preprocessor (EPP) for on board data preprocessing and filtering of the Simbol-X low-energy detector and a related Sequencer (SEQ) to generate the necessary signals to control the readout.

  1. Fast, accurate, small-scale 3D scene capture using a low-cost depth sensor

    PubMed Central

    Carey, Nicole; Nagpal, Radhika; Werfel, Justin

    2017-01-01

    Commercially available depth sensing devices are primarily designed for domains that are either macroscopic, or static. We develop a solution for fast microscale 3D reconstruction, using off-the-shelf components. By the addition of lenses, precise calibration of camera internals and positioning, and development of bespoke software, we turn an infrared depth sensor designed for human-scale motion and object detection into a device with mm-level accuracy capable of recording at up to 30Hz. PMID:28758159

  2. Magnetic Levitation Coupled with Portable Imaging and Analysis for Disease Diagnostics.

    PubMed

    Knowlton, Stephanie M; Yenilmez, Bekir; Amin, Reza; Tasoglu, Savas

    2017-02-19

    Currently, many clinical diagnostic procedures are complex, costly, inefficient, and inaccessible to a large population in the world. The requirements for specialized equipment and trained personnel require that many diagnostic tests be performed at remote, centralized clinical laboratories. Magnetic levitation is a simple yet powerful technique and can be applied to levitate cells, which are suspended in a paramagnetic solution and placed in a magnetic field, at a position determined by equilibrium between a magnetic force and a buoyancy force. Here, we present a versatile platform technology designed for point-of-care diagnostics which uses magnetic levitation coupled to microscopic imaging and automated analysis to determine the density distribution of a patient's cells as a useful diagnostic indicator. We present two platforms operating on this principle: (i) a smartphone-compatible version of the technology, where the built-in smartphone camera is used to image cells in the magnetic field and a smartphone application processes the images and to measures the density distribution of the cells and (ii) a self-contained version where a camera board is used to capture images and an embedded processing unit with attached thin-film-transistor (TFT) screen measures and displays the results. Demonstrated applications include: (i) measuring the altered distribution of a cell population with a disease phenotype compared to a healthy phenotype, which is applied to sickle cell disease diagnosis, and (ii) separation of different cell types based on their characteristic densities, which is applied to separate white blood cells from red blood cells for white blood cell cytometry. These applications, as well as future extensions of the essential density-based measurements enabled by this portable, user-friendly platform technology, will significantly enhance disease diagnostic capabilities at the point of care.

  3. Use of soft x-ray diagnostic on the COMPASS tokamak for investigations of sawteeth crash neighborhood and of plasma position using fast inversion methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Imrisek, M.; Faculty of Mathematics and Physics, Charles University in Prague, Prague; Weinzettl, V.

    2014-11-15

    The soft x-ray diagnostic is suitable for monitoring plasma activity in the tokamak core, e.g., sawtooth instability. Moreover, spatially resolved measurements can provide information about plasma position and shape, which can supplement magnetic measurements. In this contribution, fast algorithms with the potential for a real-time use are tested on the data from the COMPASS tokamak. In addition, the soft x-ray data are compared with data from other diagnostics in order to discuss possible connection between sawtooth instability on one side and the transition to higher confinement mode, edge localized modes and productions of runaway electrons on the other side.

  4. Development of an imaging method for quantifying a large digital PCR droplet

    NASA Astrophysics Data System (ADS)

    Huang, Jen-Yu; Lee, Shu-Sheng; Hsu, Yu-Hsiang

    2017-02-01

    Portable devices have been recognized as the future linkage between end-users and lab-on-a-chip devices. It has a user friendly interface and provides apps to interface headphones, cameras, and communication duct, etc. In particular, the digital resolution of cameras installed in smartphones or pads already has a high imaging resolution with a high number of pixels. This unique feature has triggered researches to integrate optical fixtures with smartphone to provide microscopic imaging capabilities. In this paper, we report our study on developing a portable diagnostic tool based on the imaging system of a smartphone and a digital PCR biochip. A computational algorithm is developed to processing optical images taken from a digital PCR biochip with a smartphone in a black box. Each reaction droplet is recorded in pixels and is analyzed in a sRGB (red, green, and blue) color space. Multistep filtering algorithm and auto-threshold algorithm are adopted to minimize background noise contributed from ccd cameras and rule out false positive droplets, respectively. Finally, a size-filtering method is applied to identify the number of positive droplets to quantify target's concentration. Statistical analysis is then performed for diagnostic purpose. This process can be integrated in an app and can provide a user friendly interface without professional training.

  5. Spectroscopic imaging of limiter heat and particle fluxes and the resulting impurity sources during Wendelstein 7-X startup plasmas.

    PubMed

    Stephey, L; Wurden, G A; Schmitz, O; Frerichs, H; Effenberg, F; Biedermann, C; Harris, J; König, R; Kornejew, P; Krychowiak, M; Unterberg, E A

    2016-11-01

    A combined IR and visible camera system [G. A. Wurden et al., "A high resolution IR/visible imaging system for the W7-X limiter," Rev. Sci. Instrum. (these proceedings)] and a filterscope system [R. J. Colchin et al., Rev. Sci. Instrum. 74, 2068 (2003)] were implemented together to obtain spectroscopic data of limiter and first wall recycling and impurity sources during Wendelstein 7-X startup plasmas. Both systems together provided excellent temporal and spatial spectroscopic resolution of limiter 3. Narrowband interference filters in front of the camera yielded C-III and H α photon flux, and the filterscope system provided H α , H β , He-I, He-II, C-II, and visible bremsstrahlung data. The filterscopes made additional measurements of several points on the W7-X vacuum vessel to yield wall recycling fluxes. The resulting photon flux from both the visible camera and filterscopes can then be compared to an EMC3-EIRENE synthetic diagnostic [H. Frerichs et al., "Synthetic plasma edge diagnostics for EMC3-EIRENE, highlighted for Wendelstein 7-X," Rev. Sci. Instrum. (these proceedings)] to infer both a limiter particle flux and wall particle flux, both of which will ultimately be used to infer the complete particle balance and particle confinement time τ P .

  6. Absolute calibration of optical streak cameras on picosecond time scales using supercontinuum generation

    DOE PAGES

    Patankar, S.; Gumbrell, E. T.; Robinson, T. S.; ...

    2017-08-17

    Here we report a new method using high stability, laser-driven supercontinuum generation in a liquid cell to calibrate the absolute photon response of fast optical streak cameras as a function of wavelength when operating at fastest sweep speeds. A stable, pulsed white light source based around the use of self-phase modulation in a salt solution was developed to provide the required brightness on picosecond timescales, enabling streak camera calibration in fully dynamic operation. The measured spectral brightness allowed for absolute photon response calibration over a broad spectral range (425-650nm). Calibrations performed with two Axis Photonique streak cameras using the Photonismore » P820PSU streak tube demonstrated responses which qualitatively follow the photocathode response. Peak sensitivities were 1 photon/count above background. The absolute dynamic sensitivity is less than the static by up to an order of magnitude. We attribute this to the dynamic response of the phosphor being lower.« less

  7. Kinect2 - respiratory movement detection study.

    PubMed

    Rihana, Sandy; Younes, Elie; Visvikis, Dimitris; Fayad, Hadi

    2016-08-01

    Radiotherapy is one of the main cancer treatments. It consists in irradiating tumor cells to destroy them while sparing healthy tissue. The treatment is planned based on Computed Tomography (CT) and is delivered over fractions during several days. One of the main challenges is replacing patient in the same position every day to irradiate the tumor volume while sparing healthy tissues. Many patient positioning techniques are available. They are both invasive and not accurate performed using tattooed marker on the patient's skin aligned with a laser system calibrated in the treatment room or irradiating using X-ray. Currently systems such as Vision RT use two Time of Flight cameras. Time of Flight cameras have the advantage of having a very fast acquisition rate allows the real time monitoring of patient movement and patient repositioning. The purpose of this work is to test the Microsoft Kinect2 camera for potential use for patient positioning and respiration trigging. This type of Time of Flight camera is non-invasive and costless which facilitate its transfer to clinical practice.

  8. Vibration extraction based on fast NCC algorithm and high-speed camera.

    PubMed

    Lei, Xiujun; Jin, Yi; Guo, Jie; Zhu, Chang'an

    2015-09-20

    In this study, a high-speed camera system is developed to complete the vibration measurement in real time and to overcome the mass introduced by conventional contact measurements. The proposed system consists of a notebook computer and a high-speed camera which can capture the images as many as 1000 frames per second. In order to process the captured images in the computer, the normalized cross-correlation (NCC) template tracking algorithm with subpixel accuracy is introduced. Additionally, a modified local search algorithm based on the NCC is proposed to reduce the computation time and to increase efficiency significantly. The modified algorithm can rapidly accomplish one displacement extraction 10 times faster than the traditional template matching without installing any target panel onto the structures. Two experiments were carried out under laboratory and outdoor conditions to validate the accuracy and efficiency of the system performance in practice. The results demonstrated the high accuracy and efficiency of the camera system in extracting vibrating signals.

  9. Optical performance analysis of plenoptic camera systems

    NASA Astrophysics Data System (ADS)

    Langguth, Christin; Oberdörster, Alexander; Brückner, Andreas; Wippermann, Frank; Bräuer, Andreas

    2014-09-01

    Adding an array of microlenses in front of the sensor transforms the capabilities of a conventional camera to capture both spatial and angular information within a single shot. This plenoptic camera is capable of obtaining depth information and providing it for a multitude of applications, e.g. artificial re-focusing of photographs. Without the need of active illumination it represents a compact and fast optical 3D acquisition technique with reduced effort in system alignment. Since the extent of the aperture limits the range of detected angles, the observed parallax is reduced compared to common stereo imaging systems, which results in a decreased depth resolution. Besides, the gain of angular information implies a degraded spatial resolution. This trade-off requires a careful choice of the optical system parameters. We present a comprehensive assessment of possible degrees of freedom in the design of plenoptic systems. Utilizing a custom-built simulation tool, the optical performance is quantified with respect to particular starting conditions. Furthermore, a plenoptic camera prototype is demonstrated in order to verify the predicted optical characteristics.

  10. Comparison of the temperature accuracy between smart phone based and high-end thermal cameras using a temperature gradient phantom

    NASA Astrophysics Data System (ADS)

    Klaessens, John H.; van der Veen, Albert; Verdaasdonk, Rudolf M.

    2017-03-01

    Recently, low cost smart phone based thermal cameras are being considered to be used in a clinical setting for monitoring physiological temperature responses such as: body temperature change, local inflammations, perfusion changes or (burn) wound healing. These thermal cameras contain uncooled micro-bolometers with an internal calibration check and have a temperature resolution of 0.1 degree. For clinical applications a fast quality measurement before use is required (absolute temperature check) and quality control (stability, repeatability, absolute temperature, absolute temperature differences) should be performed regularly. Therefore, a calibrated temperature phantom has been developed based on thermistor heating on both ends of a black coated metal strip to create a controllable temperature gradient from room temperature 26 °C up to 100 °C. The absolute temperatures on the strip are determined with software controlled 5 PT-1000 sensors using lookup tables. In this study 3 FLIR-ONE cameras and one high end camera were checked with this temperature phantom. The results show a relative good agreement between both low-cost and high-end camera's and the phantom temperature gradient, with temperature differences of 1 degree up to 6 degrees between the camera's and the phantom. The measurements were repeated as to absolute temperature and temperature stability over the sensor area. Both low-cost and high-end thermal cameras measured relative temperature changes with high accuracy and absolute temperatures with constant deviations. Low-cost smart phone based thermal cameras can be a good alternative to high-end thermal cameras for routine clinical measurements, appropriate to the research question, providing regular calibration checks for quality control.

  11. Colorimetric detection for paper-based biosensing applications

    NASA Astrophysics Data System (ADS)

    Brink, C.; Joubert, T.-H.

    2016-02-01

    Research on affordable point-of-care health diagnostics is rapidly advancing1. Colorimetric biosensor applications are typically qualitative, but recently the focus has been shifted to quantitative measurements2,3. Although numerous qualitative point-of-care (POC) health diagnostic devices are available, the challenge exists of developing a quantitative colorimetric array reader system that complies with the ASSURED (Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment-free, Deliverable to end-users) principles of the World Health Organization4. This paper presents a battery powered 8-bit tonal resolution colorimetric sensor circuit for paper microfluidic assays using low cost photo-detection circuitry and a low-power LED light source. A colorimetric 3×3-pixel array reader was developed for rural environments where resources and personnel are limited. The device sports an ultralow-power E-ink paper display. The colorimetric device includes integrated GPS functionality and EEPROM memory to log measurements with geo-tags for possible analysis of regional trends. The device competes with colour intensity measurement techniques using smartphone cameras, but proves to be a cheaper solution, compensating for the typical performance variations between cameras of different brands of smartphones. Inexpensive methods for quantifying bacterial assays have been shown using desktop scanners, which are not portable, and cameras, which suffer severely from changes in ambient light in different environments. Promising colorimetric detection results have been demonstrated using devices such as video cameras5, digital colour analysers6, flatbed scanners7 or custom portable readers8. The major drawback of most of these methods is the need for specialized instrumentation and for image analysis on a computer.

  12. Who cares about a camera if you are not speeding?

    DOT National Transportation Integrated Search

    1999-06-19

    Speeding is a hazard on both busy highways and city streets, but regular police enforcement does not work very well since dense and fast moving traffic makes it both difficult and dangerous for officers to make traditional traffic stops. The paper di...

  13. Independent motion detection with a rival penalized adaptive particle filter

    NASA Astrophysics Data System (ADS)

    Becker, Stefan; Hübner, Wolfgang; Arens, Michael

    2014-10-01

    Aggregation of pixel based motion detection into regions of interest, which include views of single moving objects in a scene is an essential pre-processing step in many vision systems. Motion events of this type provide significant information about the object type or build the basis for action recognition. Further, motion is an essential saliency measure, which is able to effectively support high level image analysis. When applied to static cameras, background subtraction methods achieve good results. On the other hand, motion aggregation on freely moving cameras is still a widely unsolved problem. The image flow, measured on a freely moving camera is the result from two major motion types. First the ego-motion of the camera and second object motion, that is independent from the camera motion. When capturing a scene with a camera these two motion types are adverse blended together. In this paper, we propose an approach to detect multiple moving objects from a mobile monocular camera system in an outdoor environment. The overall processing pipeline consists of a fast ego-motion compensation algorithm in the preprocessing stage. Real-time performance is achieved by using a sparse optical flow algorithm as an initial processing stage and a densely applied probabilistic filter in the post-processing stage. Thereby, we follow the idea proposed by Jung and Sukhatme. Normalized intensity differences originating from a sequence of ego-motion compensated difference images represent the probability of moving objects. Noise and registration artefacts are filtered out, using a Bayesian formulation. The resulting a posteriori distribution is located on image regions, showing strong amplitudes in the difference image which are in accordance with the motion prediction. In order to effectively estimate the a posteriori distribution, a particle filter is used. In addition to the fast ego-motion compensation, the main contribution of this paper is the design of the probabilistic filter for real-time detection and tracking of independently moving objects. The proposed approach introduces a competition scheme between particles in order to ensure an improved multi-modality. Further, the filter design helps to generate a particle distribution which is homogenous even in the presence of multiple targets showing non-rigid motion patterns. The effectiveness of the method is shown on exemplary outdoor sequences.

  14. Eye pupil detection system using an ensemble of regression forest and fast radial symmetry transform with a near infrared camera

    NASA Astrophysics Data System (ADS)

    Jeong, Mira; Nam, Jae-Yeal; Ko, Byoung Chul

    2017-09-01

    In this paper, we focus on pupil center detection in various video sequences that include head poses and changes in illumination. To detect the pupil center, we first find four eye landmarks in each eye by using cascade local regression based on a regression forest. Based on the rough location of the pupil, a fast radial symmetric transform is applied using the previously found pupil location to rearrange the fine pupil center. As the final step, the pupil displacement is estimated between the previous frame and the current frame to maintain the level of accuracy against a false locating result occurring in a particular frame. We generated a new face dataset, called Keimyung University pupil detection (KMUPD), with infrared camera. The proposed method was successfully applied to the KMUPD dataset, and the results indicate that its pupil center detection capability is better than that of other methods and with a shorter processing time.

  15. Evaluation of thermal helium beam and line-ratio fast diagnostic on the National Spherical Torus Experiment-Upgrade

    DOE PAGES

    Munoz Burgos, Jorge M.; Agostini, Matteo; Scarin, Paolo; ...

    2015-05-06

    A 1-D kinetic collisional radiative model (CRM) with state-of-the-art atomic data is developed and employed to simulate line emission to evaluate the Thermal Helium Beam (THB) diagnostic on NSTX-U. This diagnostic is currently in operation on RFX-mod, and it is proposed to be installed on NSTX-U. The THB system uses the intensity ratios of neutral helium lines 667.8, 706.5, and 728.1 nm to derive electron temperature (eV ) and density (cm –3) profiles. The purpose of the present analysis is to evaluate the applications of this diagnostic for determining fast (~4 μs) electron temperature and density radial profiles on themore » scrape-off layer (SOL) and edge regions of NSTX-U that are needed in turbulence studies. The diagnostic is limited by the level of detection of the 728.1 nm line, which is the weakest of the three. In conclusion, this study will also aid in future design of a similar 2-D diagnostic systems on the divertor.« less

  16. Note: Design and implementation of a home-built imaging system with low jitter for cold atom experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hachtel, A. J.; Gillette, M. C.; Clements, E. R.

    A novel home-built system for imaging cold atom samples is presented using a readily available astronomy camera which has the requisite sensitivity but no timing-control. We integrate the camera with LabVIEW achieving fast, low-jitter imaging with a convenient user-defined interface. We show that our system takes precisely timed millisecond exposures and offers significant improvements in terms of system jitter and readout time over previously reported home-built systems. Our system rivals current commercial “black box” systems in performance and user-friendliness.

  17. Designing Pattern Recognition-Based Method for Fast Visual Inspection of the Bucket Wheel Excavator Lattice Structure

    NASA Astrophysics Data System (ADS)

    Risteiu, M.; Lorincz, A.; Dobra, R.; Dasic, P.; Andras, I.; Roventa, M.

    2017-06-01

    The proposed paper shows some experimental results of a research in metallic structures inspection by using a high definition camera controller by high processing capabilities. The dedicated ARM Cortex-M4 initializes the ARM Cortex-M0 system for image acquiring. Then, by programming options, we are action for patterns (abnormal situations like metal cracks, or discontinuities) types and tuning, for enabling overexposure highlighting and adjusting camera brightness/exposure, to adjust minimum brightness, and to adjust the pattern’s teach threshold. The proposed system has been tested in normal lighting conditions from the typical site.

  18. A fast one-chip event-preprocessor and sequencer for the Simbol-X Low Energy Detector

    NASA Astrophysics Data System (ADS)

    Schanz, T.; Tenzer, C.; Maier, D.; Kendziorra, E.; Santangelo, A.

    2010-12-01

    We present an FPGA-based digital camera electronics consisting of an Event-Preprocessor (EPP) for on-board data preprocessing and a related Sequencer (SEQ) to generate the necessary signals to control the readout of the detector. The device has been originally designed for the Simbol-X low energy detector (LED). The EPP operates on 64×64 pixel images and has a real-time processing capability of more than 8000 frames per second. The already working releases of the EPP and the SEQ are now combined into one Digital-Camera-Controller-Chip (D3C).

  19. A photoelectric technique for measuring lightning-channel propagation velocities from a mobile laboratory

    NASA Technical Reports Server (NTRS)

    Mach, Douglas M.; Rust, W. David

    1989-01-01

    The present device for lightning channel propagation-velocity determination employs eight photodetectors mounted behind precision horizontal slits in the focal plane of a photographic camera lens. The eight photodetector pulses, IRIG-B time, and slow and fast electric field-change waveforms are recorded on a 14-track analog tape recorder. A comparison of the present results with those obtained by a streaking camera shows no significant differences between the velocities obtained from the same strokes with the two systems; neither is there any difference in pulse characteristics or in the velocities calculated from them.

  20. Commissioning of BL 7.2, the new diagnostic beam line at the ALS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sannibale, Fernando; Baum, Dennis; Biocca, Alan

    2004-06-29

    BL 7.2 is a new beamline at the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory (LBNL) dedicated to electron beam diagnostics. The system, which is basically a hard x-ray pinhole camera, was installed in the storage ring in August 2003 and commissioning with the ALS electron beam followed immediately after. In this paper the commissioning results are presented together with the description of the relevant measurements performed for the beamline characterization.

  1. A fast Monte Carlo EM algorithm for estimation in latent class model analysis with an application to assess diagnostic accuracy for cervical neoplasia in women with AGC

    PubMed Central

    Kang, Le; Carter, Randy; Darcy, Kathleen; Kauderer, James; Liao, Shu-Yuan

    2013-01-01

    In this article we use a latent class model (LCM) with prevalence modeled as a function of covariates to assess diagnostic test accuracy in situations where the true disease status is not observed, but observations on three or more conditionally independent diagnostic tests are available. A fast Monte Carlo EM (MCEM) algorithm with binary (disease) diagnostic data is implemented to estimate parameters of interest; namely, sensitivity, specificity, and prevalence of the disease as a function of covariates. To obtain standard errors for confidence interval construction of estimated parameters, the missing information principle is applied to adjust information matrix estimates. We compare the adjusted information matrix based standard error estimates with the bootstrap standard error estimates both obtained using the fast MCEM algorithm through an extensive Monte Carlo study. Simulation demonstrates that the adjusted information matrix approach estimates the standard error similarly with the bootstrap methods under certain scenarios. The bootstrap percentile intervals have satisfactory coverage probabilities. We then apply the LCM analysis to a real data set of 122 subjects from a Gynecologic Oncology Group (GOG) study of significant cervical lesion (S-CL) diagnosis in women with atypical glandular cells of undetermined significance (AGC) to compare the diagnostic accuracy of a histology-based evaluation, a CA-IX biomarker-based test and a human papillomavirus (HPV) DNA test. PMID:24163493

  2. International Congress on High-Speed Photography and Photonics, 19th, Cambridge, England, Sept. 16-21, 1990, Proceedings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garfield, B.R.; Rendell, J.T.

    1991-01-01

    The present conference discusses the application of schlieren photography in industry, laser fiber-optic high speed photography, holographic visualization of hypervelocity explosions, sub-100-picosec X-ray grating cameras, flash soft X-radiography, a novel approach to synchroballistic photography, a programmable image converter framing camera, high speed readout CCDs, an ultrafast optomechanical camera, a femtosec streak tube, a modular streak camera for laser ranging, and human-movement analysis with real-time imaging. Also discussed are high-speed photography of high-resolution moire patterns, a 2D electron-bombarded CCD readout for picosec electrooptical data, laser-generated plasma X-ray diagnostics, 3D shape restoration with virtual grating phase detection, Cu vapor lasers for highmore » speed photography, a two-frequency picosec laser with electrooptical feedback, the conversion of schlieren systems to high speed interferometers, laser-induced cavitation bubbles, stereo holographic cinematography, a gatable photonic detector, and laser generation of Stoneley waves at liquid-solid boundaries.« less

  3. Lock-in thermography using a cellphone attachment infrared camera

    NASA Astrophysics Data System (ADS)

    Razani, Marjan; Parkhimchyk, Artur; Tabatabaei, Nima

    2018-03-01

    Lock-in thermography (LIT) is a thermal-wave-based, non-destructive testing, technique which has been widely utilized in research settings for characterization and evaluation of biological and industrial materials. However, despite promising research outcomes, the wide spread adaptation of LIT in industry, and its commercialization, is hindered by the high cost of the infrared cameras used in the LIT setups. In this paper, we report on the feasibility of using inexpensive cellphone attachment infrared cameras for performing LIT. While the cost of such cameras is over two orders of magnitude less than their research-grade counterparts, our experimental results on block sample with subsurface defects and tooth with early dental caries suggest that acceptable performance can be achieved through careful instrumentation and implementation of proper data acquisition and image processing steps. We anticipate this study to pave the way for development of low-cost thermography systems and their commercialization as inexpensive tools for non-destructive testing of industrial samples as well as affordable clinical devices for diagnostic imaging of biological tissues.

  4. Development of a 3-D visible limiter imaging system for the HSX stellarator

    NASA Astrophysics Data System (ADS)

    Buelo, C.; Stephey, L.; Anderson, F. S. B.; Eisert, D.; Anderson, D. T.

    2017-12-01

    A visible camera diagnostic has been developed to study the Helically Symmetric eXperiment (HSX) limiter plasma interaction. A straight line view from the camera location to the limiter was not possible due to the complex 3D stellarator geometry of HSX, so it was necessary to insert a mirror/lens system into the plasma edge. A custom support structure for this optical system tailored to the HSX geometry was designed and installed. This system holds the optics tube assembly at the required angle for the desired view to both minimize system stress and facilitate robust and repeatable camera positioning. The camera system has been absolutely calibrated and using Hα and C-III filters can provide hydrogen and carbon photon fluxes, which through an S/XB coefficient can be converted into particle fluxes. The resulting measurements have been used to obtain the characteristic penetration length of hydrogen and C-III species. The hydrogen λiz value shows reasonable agreement with the value predicted by a 1D penetration length calculation.

  5. Performances Of The New Streak Camera TSN 506

    NASA Astrophysics Data System (ADS)

    Nodenot, P.; Imhoff, C.; Bouchu, M.; Cavailler, C.; Fleurot, N.; Launspach, J.

    1985-02-01

    The number of streack cameras used in research laboratory has been continuously increased du-ring the past years. The increasing of this type of equipment is due to the development of various measurement techniques in the nanosecond and picosecond range. Among the many different applications, we would mention detonics chronometry measurement, measurement of the speed of matter by means of Doppler-laser interferometry, laser and plasma diagnostics associated with laser-matter interaction. The old range of cameras have been remodelled, in order to standardize and rationalize the production of ultrafast cinematography instruments, to produce a single camera known as TSN 506. Tne TSN 506 is composed of an electronic control unit, built around the image converter tube it can be fitted with a nanosecond sweep circuit covering the whole range from 1 ms to 200 ns or with a picosecond circuit providing streak durations from 1 to 100 ns. We shall describe the main electronic and opto-electronic performance of the TSN 506 operating in these two temporal fields.

  6. Feasibility of UltraFast Doppler in Post-operative Evaluation of Hepatic Artery in Recipients following Liver Transplantation.

    PubMed

    Kim, Se-Young; Kim, Kyoung Won; Choi, Sang Hyun; Kwon, Jae Hyun; Song, Gi-Won; Kwon, Heon-Ju; Yun, Young Ju; Lee, Jeongjin; Lee, Sung-Gyu

    2017-11-01

    To determine the feasibility of using UltraFast Doppler in post-operative evaluation of the hepatic artery (HA) after liver transplantation (LT), we evaluated 283 simultaneous conventional and UltraFast Doppler sessions in 126 recipients over a 2-mo period after LT, using an Aixplorer scanner The Doppler indexes of the HA (peak systolic velocity [PSV], end-diastolic velocity [EDV], resistive index [RI] and systolic acceleration time [SAT]) by retrospective analysis of retrieved waves from UltraFast Doppler clips were compared with those obtained by conventional spectral Doppler. Correlation, performance in diagnosing the pathologic wave, examination time and reproducibility were evaluated. The PSV, EDV, RI and SAT of spectral and UltraFast Doppler measurements exhibited excellent correlation with favorable diagnostic performance. During the bedside examination, the mean time spent for UltraFast clip storing was significantly shorter than that for conventional Doppler US measurements. Both conventional and UltraFast Doppler exhibited good to excellent inter-analysis consistency. In conclusion, compared with conventional spectral Doppler, UltraFast Doppler values correlated excellently and yielded acceptable pathologic wave diagnostic performance with reduced examination time at the bedside and excellent reproducibility. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  7. Kinetic equilibrium reconstruction for the NBI- and ICRH-heated H-mode plasma on EAST tokamak

    NASA Astrophysics Data System (ADS)

    Zhen, ZHENG; Nong, XIANG; Jiale, CHEN; Siye, DING; Hongfei, DU; Guoqiang, LI; Yifeng, WANG; Haiqing, LIU; Yingying, LI; Bo, LYU; Qing, ZANG

    2018-04-01

    The equilibrium reconstruction is important to study the tokamak plasma physical processes. To analyze the contribution of fast ions to the equilibrium, the kinetic equilibria at two time-slices in a typical H-mode discharge with different auxiliary heatings are reconstructed by using magnetic diagnostics, kinetic diagnostics and TRANSP code. It is found that the fast-ion pressure might be up to one-third of the plasma pressure and the contribution is mainly in the core plasma due to the neutral beam injection power is primarily deposited in the core region. The fast-ion current contributes mainly in the core region while contributes little to the pedestal current. A steep pressure gradient in the pedestal is observed which gives rise to a strong edge current. It is proved that the fast ion effects cannot be ignored and should be considered in the future study of EAST.

  8. Aquatic Debris Detection Using Embedded Camera Sensors

    PubMed Central

    Wang, Yong; Wang, Dianhong; Lu, Qian; Luo, Dapeng; Fang, Wu

    2015-01-01

    Aquatic debris monitoring is of great importance to human health, aquatic habitats and water transport. In this paper, we first introduce the prototype of an aquatic sensor node equipped with an embedded camera sensor. Based on this sensing platform, we propose a fast and accurate debris detection algorithm. Our method is specifically designed based on compressive sensing theory to give full consideration to the unique challenges in aquatic environments, such as waves, swaying reflections, and tight energy budget. To upload debris images, we use an efficient sparse recovery algorithm in which only a few linear measurements need to be transmitted for image reconstruction. Besides, we implement the host software and test the debris detection algorithm on realistically deployed aquatic sensor nodes. The experimental results demonstrate that our approach is reliable and feasible for debris detection using camera sensors in aquatic environments. PMID:25647741

  9. Comparing light sensitivity, linearity and step response of electronic cameras for ophthalmology.

    PubMed

    Kopp, O; Markert, S; Tornow, R P

    2002-01-01

    To develop and test a procedure to measure and compare light sensitivity, linearity and step response of electronic cameras. The pixel value (PV) of digitized images as a function of light intensity (I) was measured. The sensitivity was calculated from the slope of the P(I) function, the linearity was estimated from the correlation coefficient of this function. To measure the step response, a short sequence of images was acquired. During acquisition, a light source was switched on and off using a fast shutter. The resulting PV was calculated for each video field of the sequence. A CCD camera optimized for the near-infrared (IR) spectrum showed the highest sensitivity for both, visible and IR light. There are little differences in linearity. The step response depends on the procedure of integration and read out.

  10. Digital readout for image converter cameras

    NASA Astrophysics Data System (ADS)

    Honour, Joseph

    1991-04-01

    There is an increasing need for fast and reliable analysis of recorded sequences from image converter cameras so that experimental information can be readily evaluated without recourse to more time consuming photographic procedures. A digital readout system has been developed using a randomly triggerable high resolution CCD camera, the output of which is suitable for use with IBM AT compatible PC. Within half a second from receipt of trigger pulse, the frame reformatter displays the image and transfer to storage media can be readily achieved via the PC and dedicated software. Two software programmes offer different levels of image manipulation which includes enhancement routines and parameter calculations with accuracy down to pixel levels. Hard copy prints can be acquired using a specially adapted Polaroid printer, outputs for laser and video printer extend the overall versatility of the system.

  11. Data transmission protocol for Pi-of-the-Sky cameras

    NASA Astrophysics Data System (ADS)

    Uzycki, J.; Kasprowicz, G.; Mankiewicz, M.; Nawrocki, K.; Sitek, P.; Sokolowski, M.; Sulej, R.; Tlaczala, W.

    2006-10-01

    The large amount of data collected by the automatic astronomical cameras has to be transferred to the fast computers in a reliable way. The method chosen should ensure data streaming in both directions but in nonsymmetrical way. The Ethernet interface is very good choice because of its popularity and proven performance. However it requires TCP/IP stack implementation in devices like cameras for full compliance with existing network and operating systems. This paper describes NUDP protocol, which was made as supplement to standard UDP protocol and can be used as a simple-network protocol. The NUDP does not need TCP protocol implementation and makes it possible to run the Ethernet network with simple devices based on microcontroller and/or FPGA chips. The data transmission idea was created especially for the "Pi of the Sky" project.

  12. Performance of the prototype LaBr3 spectrometer developed for the JET gamma-ray camera upgrade.

    PubMed

    Rigamonti, D; Muraro, A; Nocente, M; Perseo, V; Boltruczyk, G; Fernandes, A; Figueiredo, J; Giacomelli, L; Gorini, G; Gosk, M; Kiptily, V; Korolczuk, S; Mianowski, S; Murari, A; Pereira, R C; Cippo, E P; Zychor, I; Tardocchi, M

    2016-11-01

    In this work, we describe the solution developed by the gamma ray camera upgrade enhancement project to improve the spectroscopic properties of the existing JET γ-ray camera. Aim of the project is to enable gamma-ray spectroscopy in JET deuterium-tritium plasmas. A dedicated pilot spectrometer based on a LaBr 3 crystal coupled to a silicon photo-multiplier has been developed. A proper pole zero cancellation network able to shorten the output signal to a length of 120 ns has been implemented allowing for spectroscopy at MHz count rates. The system has been characterized in the laboratory and shows an energy resolution of 5.5% at E γ = 0.662 MeV, which extrapolates favorably in the energy range of interest for gamma-ray emission from fast ions in fusion plasmas.

  13. Status of US ITER Diagnostics

    NASA Astrophysics Data System (ADS)

    Stratton, B.; Delgado-Aparicio, L.; Hill, K.; Johnson, D.; Pablant, N.; Barnsley, R.; Bertschinger, G.; de Bock, M. F. M.; Reichle, R.; Udintsev, V. S.; Watts, C.; Austin, M.; Phillips, P.; Beiersdorfer, P.; Biewer, T. M.; Hanson, G.; Klepper, C. C.; Carlstrom, T.; van Zeeland, M. A.; Brower, D.; Doyle, E.; Peebles, A.; Ellis, R.; Levinton, F.; Yuh, H.

    2013-10-01

    The US is providing 7 diagnostics to ITER: the Upper Visible/IR cameras, the Low Field Side Reflectometer, the Motional Stark Effect diagnostic, the Electron Cyclotron Emission diagnostic, the Toroidal Interferometer/Polarimeter, the Core Imaging X-Ray Spectrometer, and the Diagnostic Residual Gas Analyzer. The front-end components of these systems must operate with high reliability in conditions of long pulse operation, high neutron and gamma fluxes, very high neutron fluence, significant neutron heating (up to 7 MW/m3) , large radiant and charge exchange heat flux (0.35 MW/m2) , and high electromagnetic loads. Opportunities for repair and maintenance of these components will be limited. These conditions lead to significant challenges for the design of the diagnostics. Space constraints, provision of adequate radiation shielding, and development of repair and maintenance strategies are challenges for diagnostic integration into the port plugs that also affect diagnostic design. The current status of design of the US ITER diagnostics is presented and R&D needs are identified. Supported by DOE contracts DE-AC02-09CH11466 (PPPL) and DE-AC05-00OR22725 (UT-Battelle, LLC).

  14. Towards Kilo-Hertz 6-DoF Visual Tracking Using an Egocentric Cluster of Rolling Shutter Cameras.

    PubMed

    Bapat, Akash; Dunn, Enrique; Frahm, Jan-Michael

    2016-11-01

    To maintain a reliable registration of the virtual world with the real world, augmented reality (AR) applications require highly accurate, low-latency tracking of the device. In this paper, we propose a novel method for performing this fast 6-DOF head pose tracking using a cluster of rolling shutter cameras. The key idea is that a rolling shutter camera works by capturing the rows of an image in rapid succession, essentially acting as a high-frequency 1D image sensor. By integrating multiple rolling shutter cameras on the AR device, our tracker is able to perform 6-DOF markerless tracking in a static indoor environment with minimal latency. Compared to state-of-the-art tracking systems, this tracking approach performs at significantly higher frequency, and it works in generalized environments. To demonstrate the feasibility of our system, we present thorough evaluations on synthetically generated data with tracking frequencies reaching 56.7 kHz. We further validate the method's accuracy on real-world images collected from a prototype of our tracking system against ground truth data using standard commodity GoPro cameras capturing at 120 Hz frame rate.

  15. An optimal algorithm for reconstructing images from binary measurements

    NASA Astrophysics Data System (ADS)

    Yang, Feng; Lu, Yue M.; Sbaiz, Luciano; Vetterli, Martin

    2010-01-01

    We have studied a camera with a very large number of binary pixels referred to as the gigavision camera [1] or the gigapixel digital film camera [2, 3]. Potential advantages of this new camera design include improved dynamic range, thanks to its logarithmic sensor response curve, and reduced exposure time in low light conditions, due to its highly sensitive photon detection mechanism. We use maximum likelihood estimator (MLE) to reconstruct a high quality conventional image from the binary sensor measurements of the gigavision camera. We prove that when the threshold T is "1", the negative loglikelihood function is a convex function. Therefore, optimal solution can be achieved using convex optimization. Base on filter bank techniques, fast algorithms are given for computing the gradient and the multiplication of a vector and Hessian matrix of the negative log-likelihood function. We show that with a minor change, our algorithm also works for estimating conventional images from multiple binary images. Numerical experiments with synthetic 1-D signals and images verify the effectiveness and quality of the proposed algorithm. Experimental results also show that estimation performance can be improved by increasing the oversampling factor or the number of binary images.

  16. Fast synchronized dual-wavelength laser speckle imaging system for monitoring hemodynamic changes in a stroke mouse model

    PubMed Central

    Qin, Jia; Shi, Lei; Dziennis, Suzan; Reif, Roberto; Wang, Ruikang K.

    2014-01-01

    In this paper, we describe a newly developed synchronized dual-wavelength laser speckle contrast imaging (SDW-LSCI) system, which contains two cameras that are synchronously triggered to acquire data. The system can acquire data at a high spatiotemporal resolution (up to 500Hz for ~1000×1000 pixels). A mouse model of stroke is used to demonstrate the capability for imaging the fast changes (within tens of milliseconds) in oxygenated and deoxygenated hemoglobin concentration, and the relative changes in blood flow in the mouse brain, through an intact cranium. This novel imaging technology will enable the study of fast hemodynamics and metabolic changes in vascular diseases. PMID:23027260

  17. Infrared Camera Diagnostic for Heat Flux Measurements on NSTX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D. Mastrovito; R. Maingi; H.W. Kugel

    2003-03-25

    An infrared imaging system has been installed on NSTX (National Spherical Torus Experiment) at the Princeton Plasma Physics Laboratory to measure the surface temperatures on the lower divertor and center stack. The imaging system is based on an Indigo Alpha 160 x 128 microbolometer camera with 12 bits/pixel operating in the 7-13 {micro}m range with a 30 Hz frame rate and a dynamic temperature range of 0-700 degrees C. From these data and knowledge of graphite thermal properties, the heat flux is derived with a classic one-dimensional conduction model. Preliminary results of heat flux scaling are reported.

  18. Space experiments with particle accelerators

    NASA Technical Reports Server (NTRS)

    Obayashi, T.; Kawashima, N.; Kuriki, K.; Nagatomo, M.; Ninomiya, K.; Sasaki, S.; Roberts, W. T.; Chappell, C. R.; Reasoner, D. L.; Garriott, O. K.; hide

    1984-01-01

    Electron and plasma beams and neutral gas plumes were injected into the space environment by instruuments on Spacelab 1, and various diagnostic measurements including television camera observations were performed. The results yield information on vehicle charging and neutralization, beam-plasma interactions, and ionization enhancement by neutral beam injection.

  19. Operation minute gun, shot Diana Moon. Summary report. (Sanitized version)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bower, J.A.B.; Nance, O.A.

    1973-12-31

    Typical device diagnostic experiments such as filter fluorescers, a calorimeter, a pinhole camera, a bent crystal spectrometer, and passive dosimetry were also present on Diana Moon. The test was considered a complete success with over 95 percent of the experimental data being recovered.

  20. High-level intuitive features (HLIFs) for intuitive skin lesion description.

    PubMed

    Amelard, Robert; Glaister, Jeffrey; Wong, Alexander; Clausi, David A

    2015-03-01

    A set of high-level intuitive features (HLIFs) is proposed to quantitatively describe melanoma in standard camera images. Melanoma is the deadliest form of skin cancer. With rising incidence rates and subjectivity in current clinical detection methods, there is a need for melanoma decision support systems. Feature extraction is a critical step in melanoma decision support systems. Existing feature sets for analyzing standard camera images are comprised of low-level features, which exist in high-dimensional feature spaces and limit the system's ability to convey intuitive diagnostic rationale. The proposed HLIFs were designed to model the ABCD criteria commonly used by dermatologists such that each HLIF represents a human-observable characteristic. As such, intuitive diagnostic rationale can be conveyed to the user. Experimental results show that concatenating the proposed HLIFs with a full low-level feature set increased classification accuracy, and that HLIFs were able to separate the data better than low-level features with statistical significance. An example of a graphical interface for providing intuitive rationale is given.

  1. [Diagnostic use of positron emission tomography in France: from the coincidence gamma-camera to mobile hybrid PET/CT devices].

    PubMed

    Talbot, Jean-Noël

    2010-11-01

    Positron emission tomography (PET) is a well-established medical imaging method. PET is increasingly used for diagnostic purposes, especially in oncology. The most widely used radiopharmaceutical is FDG, a glucose analogue. Other radiopharmaceuticals have recently been registered or are in development. We outline technical improvements of PET machines during more than a decade of clinical use in France. Even though image quality has improved considerably and PET-CT hybrid machines have emerged, spending per examination has remained remarkably constant. Replacement and maintenance costs have remained in the range of 170-190 Euros per examination since 1997, whether early CDET gamma cameras or the latest time-of-flight PET/CT devices are used. This is mainly due to shorter acquisition times and more efficient use of FDG New reimbursement rates for PET/CT are needed in France in order to favor regular acquisition of state-of-the-art devices. One major development is the coupling of PET and MR imaging.

  2. Study of laser-generated debris free x-ray sources produced in a high-density linear Ar, Kr, Xe, Kr/Ar and Xe/Kr/Ar mixtures gas jets by 2 ω, sub-ps LLNL Titan laser

    NASA Astrophysics Data System (ADS)

    Kantsyrev, V. L.; Schultz, K. A.; Shlyaptseva, V. V.; Safronova, A. S.; Cooper, M. C.; Shrestha, I. K.; Petkov, E. E.; Stafford, A.; Moschella, J. J.; Schmidt-Petersen, M. T.; Butcher, C. J.; Kemp, G. E.; Andrews, S. D.; Fournier, K. B.

    2016-10-01

    The study of laser-generated debris-free x-ray sources in an underdense plasma produced in a high-density linear gas-puff jet was carried out at the LLNL Titan laser (2 ω, 45 J, sub-ps) with an intensity in the 10 um focal spot of 7 x 1019 W/cm2. A linear nozzle with a fast valve was used for the generation of a clusters/gas jet. X-ray diagnostics for the spectral region of 0.7 - 9 keV include: two spectrometers and pinhole cameras, and 3 groups of fast filtered detectors. Electron beams were measured with the EPPS magnetic spectrometer (>1 MeV) and Faraday cups (>72 keV). Spectralon/spectrometer devices were also used to measure absorption of laser radiation in the jets. New results were obtained on: anisotropic generation of x-rays (laser to x-ray conversion coefficient was >1%) and characteristics of laser-generated electron beams; evolution of x-ray generation with the location of the laser focus in a cluster-gas jet, and observations of a strong x-ray flash in some focusing regimes. Non-LTE kinetic modeling was used to estimate plasma parameters. UNR work supported by the DTRA Basic Research Award # HDTRA1-13-1-0033. Work at LLNL was performed under the auspices of the U.S. DOE by LLNL under Contract DE-AC52-07NA27344.

  3. IrLaW an OGC compliant infrared thermography measurement system developed on mini PC with real time computing capabilities for long term monitoring of transport infrastructures

    NASA Astrophysics Data System (ADS)

    Dumoulin, J.; Averty, R.

    2012-04-01

    One of the objectives of ISTIMES project is to evaluate the potentialities offered by the integration of different electromagnetic techniques able to perform non-invasive diagnostics for surveillance and monitoring of transport infrastructures. Among the EM methods investigated, uncooled infrared camera is a promising technique due to its dissemination potential according to its relative low cost on the market. Infrared thermography, when it is used in quantitative mode (not in laboratory conditions) and not in qualitative mode (vision applied to survey), requires to process in real time thermal radiative corrections on raw data acquired to take into account influences of natural environment evolution with time. But, camera sensor has to be enough smart to apply in real time calibration law and radiometric corrections in a varying atmosphere. So, a complete measurement system was studied and developed with low cost infrared cameras available on the market. In the system developed, infrared camera is coupled with other sensors to feed simplified radiative models running, in real time, on GPU available on small PC. The system studied and developed uses a fast Ethernet camera FLIR A320 [1] coupled with a VAISALA WXT520 [2] weather station and a light GPS unit [3] for positioning and dating. It can be used with other Ethernet infrared cameras (i.e. visible ones) but requires to be able to access measured data at raw level. In the present study, it has been made possible thanks to a specific agreement signed with FLIR Company. The prototype system studied and developed is implemented on low cost small computer that integrates a GPU card to allow real time parallel computing [4] of simplified radiometric [5] heat balance using information measured with the weather station. An HMI was developed under Linux using OpenSource and complementary pieces of software developed at IFSTTAR. This new HMI called "IrLaW" has various functionalities that let it compliant to be use in real site for long term monitoring. It can be remotely controlled in wire or wireless communication mode depending on what is the context of measurement and the degree of accessibility to the system when it is running on real site. To complete and conclude, thanks to the development of a high level library, but also to the deployment of a daemon, our developed measurement system was tuned to be compatible with OGC standards. Complementary functionalities were also developed to allow the system to self declare to 52North. For that, a specific plugin was developed to be inserted previously at 52North level. Finally, data are also accessible by tasking the system when required, fort instance by using the web portal developed in the ISTIMES Framework. ACKNOWLEDGEMENT - The research leading to these results has received funding from the European Community's Seventh Framework Programme (FP7/2007-2013) under Grant Agreement n° 225663.

  4. Nonintrusive iris image acquisition system based on a pan-tilt-zoom camera and light stripe projection

    NASA Astrophysics Data System (ADS)

    Yoon, Soweon; Jung, Ho Gi; Park, Kang Ryoung; Kim, Jaihie

    2009-03-01

    Although iris recognition is one of the most accurate biometric technologies, it has not yet been widely used in practical applications. This is mainly due to user inconvenience during the image acquisition phase. Specifically, users try to adjust their eye position within small capture volume at a close distance from the system. To overcome these problems, we propose a novel iris image acquisition system that provides users with unconstrained environments: a large operating range, enabling movement from standing posture, and capturing good-quality iris images in an acceptable time. The proposed system has the following three contributions compared with previous works: (1) the capture volume is significantly increased by using a pan-tilt-zoom (PTZ) camera guided by a light stripe projection, (2) the iris location in the large capture volume is found fast due to 1-D vertical face searching from the user's horizontal position obtained by the light stripe projection, and (3) zooming and focusing on the user's irises at a distance are accurate and fast using the estimated 3-D position of a face by the light stripe projection and the PTZ camera. Experimental results show that the proposed system can capture good-quality iris images in 2.479 s on average at a distance of 1.5 to 3 m, while allowing a limited amount of movement by the user.

  5. Laser-induced incandescence (LII) diagnostic for in situ monitoring of nanoparticle synthesis in a high-pressure arc discharge

    NASA Astrophysics Data System (ADS)

    Yatom, Shurik; Vekselman, Vladislav; Mitrani, James; Stratton, Brentley; Raitses, Yevgeny; LaboratoryPlasma Nanosynthesis Team

    2016-10-01

    A DC arc discharge is commonly used for synthesis of carbon nanoparticles, including buckyballs, carbon nanotubes, and graphene flakes. In this work we show the first results of nanoparticles monitored during the arc discharge. The graphite electrode is vaporized by high current (60 A) in a buffer Helium gas leading to nanoparticle synthesis in a low temperature plasma. The arc was shown to oscillate, which can possibly influence the nano-synthesis. To visualize the nanoparticles in-situ we employ the LII technique. The nanoparticles with radii >50 nm, emerging from the arc area are heated with a short laser pulse and incandesce. The resulting radiation is captured with an ICCD camera, showing the location of the generated nanoparticles. The images of incandescence are studied together with temporally synchronized fast-framing imaging of C2 emission, to connect the dynamics of arc instabilities, C2 molecules concentration and nanoparticles. The time-resolved incandescence signal is analyzed with combination of ex-situ measurements of the synthesized nanoparticles and LII modeling, to provide the size distribution of produced nanoparticles. This work was supported by US Department of Energy, Office of Science, Basic Energy Sciences, Materials Sciences and Engineering Division.

  6. Experimental studies of collisional plasma shocks and plasma interpenetration via merging supersonic plasma jets

    NASA Astrophysics Data System (ADS)

    Hsu, S. C.; Moser, A. L.; Merritt, E. C.; Adams, C. S.

    2015-11-01

    Over the past 4 years on the Plasma Liner Experiment (PLX) at LANL, we have studied obliquely and head-on-merging supersonic plasma jets of an argon/impurity or hydrogen/impurity mixture. The jets are formed/launched by pulsed-power-driven railguns. In successive experimental campaigns, we characterized the (a) evolution of plasma parameters of a single plasma jet as it propagated up to ~ 1 m away from the railgun nozzle, (b) density profiles and 2D morphology of the stagnation layer and oblique shocks that formed between obliquely merging jets, and (c) collisionless interpenetration transitioning to collisional stagnation between head-on-merging jets. Key plasma diagnostics included a fast-framing CCD camera, an 8-chord visible interferometer, a survey spectrometer, and a photodiode array. This talk summarizes the primary results mentioned above, and highlights analyses of inferred post-shock temperatures based on observations of density gradients that we attribute to shock-layer thickness. We also briefly describe more recent PLX experiments on Rayleigh-Taylor-instability evolution with magnetic and viscous effects, and potential future collisionless shock experiments enabled by low-impurity, higher-velocity plasma jets formed by contoured-gap coaxial guns. Supported by DOE Fusion Energy Sciences and LANL LDRD.

  7. Multivendor nuclear medicine PACS provide fully digital clinical operation at the University of Miami/Jackson Memorial Hospital

    NASA Astrophysics Data System (ADS)

    Georgiou, Mike F.; Sfakianakis, George N.; Johnson, Gary; Douligeris, Christos; Scandar, Silvia; Eisler, E.; Binkley, B.

    1994-05-01

    In an effort to improve patient care while considering cost-effectiveness, we developed a Picture Archiving and Communication System (PACS), which combines imaging cameras, computers and other peripheral equipment from multiple nuclear medicine vectors. The PACS provides fully-digital clinical operation which includes acquisition and automatic organization of patient data, distribution of the data to all networked units inside the department and other remote locations, digital analysis and quantitation of images, digital diagnostic reading of image studies and permanent data archival with the ability for fast retrieval. The PACS enabled us to significantly reduce the amount of film used, and we are currently proceeding with implementing a film-less laboratory. Hard copies are produced on paper or transparent sheets for non-digitally connected parts of the hospital. The PACS provides full-digital operation which is faster, more reliable, better organized and managed, and overall more efficient than a conventional film-based operation. In this paper, the integration of the various PACS components from multiple vendors is reviewed, and the impact of PACS, with its advantages and limitations on our clinical operation is analyzed.

  8. Advances in Low-Temperature Tungsten Spectroscopy Capability to Quantify DIII-D Divertor Erosion

    DOE PAGES

    Abrams, Tyler; Thomas, Daniel M.; Unterberg, Ezekial A.; ...

    2018-01-05

    Recent emphasis of tungsten (W) plasma-materialsinteractions (PMI) experiments on DIII-D has made it essential to enhance the W I and W II measurement capabilities of its spectroscopy diagnostic suite to acquire W sourcing measurements with high temporal, spatial, and wavelength resolution. To this end, four new viewing chords for the Multichordal Divertor Spectrometer (MDS) and diverter filterscope systems were installed, leading to a 7x increase in blue light sensitivity. W I and low-Z impurity line identifications were performed in the 3995-4030 Å region, placing wavelengths within 0.1 Å of the NIST values. A novel method was also developed for themore » DIII-D high temporal resolution filterscopes to distinguish between W I light and background contamination, important due to the relatively weak intensity of this line, using two different bandpass filters width different widths but the same center wavelength. Lastly, fast imaging of the W I 4008.75 Å spectral line with a PCO Pixelfly VGA 200/205 camera allowed for discrimination between ELMy and intra-ELM W I emission profiles with very high (~1 mm) spatial resolution.« less

  9. Colliding Laser-Produced Plasmas on LaPD

    NASA Astrophysics Data System (ADS)

    Collette, Andrew; Gekelman, Walter

    2007-11-01

    The expansion and interaction of dense plasmas in the presence of a magnetized background plasma is important in many astrophysical processes, among them coronal mass ejections and the many examples of plasma jets from astrophotography. Turbulence is expected to be present in many such configurations. We describe a series of experiments which involve the collision of two dense (initially, n > 10^15cm-3) laser-produced plasmas within an ambient, highly magnetized plasma. The laser-produced plasmas form diamagnetic cavities in which a large percentage of the background magnetic field (600G) has been expelled. First-stage observations using a fast (3ns exposure) camera indicate complicated structure at late times, in addition to coherent corrugated structures on the bubble surfaces. The data hint at the presence of turbulence in the interaction. The second stage of observation consists of direct investigation of the magnetic field using probes. A novel diagnostic system composed of small (300-500 micron) 3-axis differential magnetic field probes in conjunction with a ceramic motor system capable of extremely fine (sub-micron) positioning accuracy is currently under development. An ensemble of magnetic field data from fixed and movable probes makes possible the calculation of the cross-spectral function.

  10. Advances in Low-Temperature Tungsten Spectroscopy Capability to Quantify DIII-D Divertor Erosion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abrams, Tyler; Thomas, Daniel M.; Unterberg, Ezekial A.

    Recent emphasis of tungsten (W) plasma-materialsinteractions (PMI) experiments on DIII-D has made it essential to enhance the W I and W II measurement capabilities of its spectroscopy diagnostic suite to acquire W sourcing measurements with high temporal, spatial, and wavelength resolution. To this end, four new viewing chords for the Multichordal Divertor Spectrometer (MDS) and diverter filterscope systems were installed, leading to a 7x increase in blue light sensitivity. W I and low-Z impurity line identifications were performed in the 3995-4030 Å region, placing wavelengths within 0.1 Å of the NIST values. A novel method was also developed for themore » DIII-D high temporal resolution filterscopes to distinguish between W I light and background contamination, important due to the relatively weak intensity of this line, using two different bandpass filters width different widths but the same center wavelength. Lastly, fast imaging of the W I 4008.75 Å spectral line with a PCO Pixelfly VGA 200/205 camera allowed for discrimination between ELMy and intra-ELM W I emission profiles with very high (~1 mm) spatial resolution.« less

  11. Dynamic light scattering microscopy

    NASA Astrophysics Data System (ADS)

    Dzakpasu, Rhonda

    An optical microscope technique, dynamic light scattering microscopy (DLSM) that images dynamically scattered light fluctuation decay rates is introduced. Using physical optics we show theoretically that within the optical resolution of the microscope, relative motions between scattering centers are sufficient to produce significant phase variations resulting in interference intensity fluctuations in the image plane. The time scale for these intensity fluctuations is predicted. The spatial coherence distance defining the average distance between constructive and destructive interference in the image plane is calculated and compared with the pixel size. We experimentally tested DLSM on polystyrene latex nanospheres and living macrophage cells. In order to record these rapid fluctuations, on a slow progressive scan CCD camera, we used a thin laser line of illumination on the sample such that only a single column of pixels in the CCD camera is illuminated. This allowed the use of the rate of the column-by-column readout transfer process as the acquisition rate of the camera. This manipulation increased the data acquisition rate by at least an order of magnitude in comparison to conventional CCD cameras rates defined by frames/s. Analysis of the observed fluctuations provides information regarding the rates of motion of the scattering centers. These rates, acquired from each position on the sample are used to create a spatial map of the fluctuation decay rates. Our experiments show that with this technique, we are able to achieve a good signal-to-noise ratio and can monitor fast intensity fluctuations, on the order of milliseconds. DLSM appears to provide dynamic information about fast motions within cells at a sub-optical resolution scale and provides a new kind of spatial contrast.

  12. Real-time x-ray diffraction measurements of shocked polycrystalline tin and aluminum.

    PubMed

    Morgan, Dane V; Macy, Don; Stevens, Gerald

    2008-11-01

    A new, fast, single-pulse x-ray diffraction (XRD) diagnostic for determining phase transitions in shocked polycrystalline materials has been developed. The diagnostic consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, producing line and bremsstrahlung x-ray emission in a 35 ns pulse. The characteristic K(alpha) lines from the selected anodes of silver and molybdenum are used to produce the diffraction patterns, with thin foil filters employed to remove the characteristic K(beta) line emission. The x-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 3 x 6 mm(2) spot and 1 degrees full width half maximum angular divergence in a Bragg-reflecting geometry. For the experiments described in this report, the angle between the incident beam and the sample surface was 8.5 degrees . A Debye-Scherrer diffraction image was produced on a phosphor located 76 mm from the polycrystalline sample surface. The phosphor image was coupled to a charge-coupled device camera through a coherent fiber-optic bundle. Dynamic single-pulse XRD experiments were conducted with thin foil samples of tin, shock loaded with a 1 mm vitreous carbon back window. Detasheet high explosive with a 2-mm-thick aluminum buffer was used to shock the sample. Analysis of the dynamic shock-loaded tin XRD images revealed a phase transformation of the tin beta phase into an amorphous or liquid state. Identical experiments with shock-loaded aluminum indicated compression of the face-centered-cubic aluminum lattice with no phase transformation.

  13. Digitizing the ranges

    NASA Astrophysics Data System (ADS)

    Haddleton, Graham P.

    2001-04-01

    In military research and development or testing there are various fast and dangerous events that need to be recorded and analyzed. High-speed cameras allow the capture of movement too fast to be recognized by the human eye, and provide data that is essential for the analysis and evaluation of such events. High-speed photography is often the only type of instrumentation that can be used to record the parameters demanded by our customers. I will show examples where this applied cinematography is used not only to provide a visual record of events, but also as an essential measurement tool.

  14. Thermodynamics of Gases: Combustion Processes, Analysed in Slow Motion

    ERIC Educational Resources Information Center

    Vollmer, Michael; Mollmann, Klaus-Peter

    2013-01-01

    We present a number of simple demonstration experiments recorded with high-speed cameras in the fields of gas dynamics and thermal physics. The experiments feature relatively slow combustion processes of pure hydrogen as well as fast reactions involving oxy-hydrogen in a stoichiometric mixture. (Contains 4 figures.)

  15. Upgraded cameras for the HESS imaging atmospheric Cherenkov telescopes

    NASA Astrophysics Data System (ADS)

    Giavitto, Gianluca; Ashton, Terry; Balzer, Arnim; Berge, David; Brun, Francois; Chaminade, Thomas; Delagnes, Eric; Fontaine, Gérard; Füßling, Matthias; Giebels, Berrie; Glicenstein, Jean-François; Gräber, Tobias; Hinton, James; Jahnke, Albert; Klepser, Stefan; Kossatz, Marko; Kretzschmann, Axel; Lefranc, Valentin; Leich, Holger; Lüdecke, Hartmut; Lypova, Iryna; Manigot, Pascal; Marandon, Vincent; Moulin, Emmanuel; de Naurois, Mathieu; Nayman, Patrick; Penno, Marek; Ross, Duncan; Salek, David; Schade, Markus; Schwab, Thomas; Simoni, Rachel; Stegmann, Christian; Steppa, Constantin; Thornhill, Julian; Toussnel, François

    2016-08-01

    The High Energy Stereoscopic System (H.E.S.S.) is an array of five imaging atmospheric Cherenkov telescopes, sensitive to cosmic gamma rays of energies between 30 GeV and several tens of TeV. Four of them started operations in 2003 and their photomultiplier tube (PMT) cameras are currently undergoing a major upgrade, with the goals of improving the overall performance of the array and reducing the failure rate of the ageing systems. With the exception of the 960 PMTs, all components inside the camera have been replaced: these include the readout and trigger electronics, the power, ventilation and pneumatic systems and the control and data acquisition software. New designs and technical solutions have been introduced: the readout makes use of the NECTAr analog memory chip, which samples and stores the PMT signals and was developed for the Cherenkov Telescope Array (CTA). The control of all hardware subsystems is carried out by an FPGA coupled to an embedded ARM computer, a modular design which has proven to be very fast and reliable. The new camera software is based on modern C++ libraries such as Apache Thrift, ØMQ and Protocol buffers, offering very good performance, robustness, flexibility and ease of development. The first camera was upgraded in 2015, the other three cameras are foreseen to follow in fall 2016. We describe the design, the performance, the results of the tests and the lessons learned from the first upgraded H.E.S.S. camera.

  16. First step toward translation of thermophotonic lock-in imaging to dentistry as an early caries detection technology

    NASA Astrophysics Data System (ADS)

    Ojaghi, Ashkan; Parkhimchyk, Artur; Tabatabaei, Nima

    2016-09-01

    Early detection of the most prevalent oral disease worldwide, i.e., dental caries, still remains as one of the major challenges in dentistry. The current dental standard of care relies on caries detection methods, such as visual inspection and x-ray radiography, which lack the sufficient specificity and sensitivity to detect caries at early stages of formation when they can be healed. We report on the feasibility of early caries detection in a clinically and commercially viable thermophotonic imaging system. The system incorporates intensity-modulated laser light along with a low-cost long-wavelength infrared (LWIR; 8 to 14 μm) camera, providing diagnostic contrast based on the enhanced light absorption of early caries. The LWIR camera is highly suitable for integration into clinical platforms because of its low weight and cost. In addition, through theoretical modeling, we show that LWIR detection enhances the diagnostic contrast due to the minimal LWIR transmittance of enamel and suppression of the masking effect of the direct thermal Planck emission. Diagnostic performance of the system and its detection threshold are experimentally evaluated by monitoring the inception and progression of artificially induced occlusal and smooth surface caries. The results are suggestive of the suitability of the developed LWIR system for detecting early dental caries.

  17. Video Diagnostic for W7-X Stellarator

    NASA Astrophysics Data System (ADS)

    Sárközi, J.; Grosser, K.; Kocsis, G.; König, R.; Neuner, U.; Molnár, Á.; Petravich, G.; Por, G.; Porempovics, G.; Récsei, S.; Szabó, V.; Szappanos, A.; Zoletnik, S.

    2008-03-01

    The video diagnostics for W7-X—which is under development—is devoted to observe plasma and frrst wall elements during operation, to warn in case of hot spots and dangerous heat load and to give information about the plasma size, position, edge structure, the geometry and location of magnetic islands and distribution of impurities. The video diagnostics will be mounted on the tangential AEQ-ports of the torus that are not straight and have about 2m length and a typical diameter of 0.1m which makes its realization more difficult. The geometry of the 10 tangential views of the AEQ-ports allows giving an almost complete overview of the vessel interior making this diagnostic indispensable for the machine operation. Different concepts of the diagnostics were investigated and finally the following design was selected. As a large heat load is expected on the optical window located at the plasma-facing end of the AEQ-port, the port window is protected by a cooled pinhole. An uncooled shutter located behind the pinhole can be closed to prevent window contamination during vessel conditioning discharges (glow discharge cleaning) and from inter-pulse deposition of soft a-C:H layers. The imaging optics and the detection sensor are located behind the port window in the port tube, which will be under atmospheric pressure. To detect the visible radiation distribution a new camera system called Event Detection Intelligent Camera (EDICAM) is under development. The system is divided into three major separated components. The Sensor Module contains only the selected CMOS sensor, the analog digital converters and the minimal electronics necessary for the communication with the subsequent camera system module called Image Processing and Control Unit (IPCU). Its simple structure makes the Sensor Module suitable to operate despite being exposed to ionizing (neutron, γ-) radiation. The IPCU, which can be located far from the Sensor Module and therefore far from the plasma, is designed to perform real time evaluation of the images detecting predefined events, managing the sensor read-out and the input triggers and producing the output triggers generated by the detected events. The IPCU can also be used to reduce the amount of the stored data. A Standard 10 Gigabit Ethernet fiber optics connection connects the IPCU module to the PC with GigEVision communication protocol.

  18. The use of digital images in pathology.

    PubMed

    Furness, P N

    1997-11-01

    Digital images are routinely used by the publishing industry, but most diagnostic pathologists are unfamiliar with the technology and its possibilities. This review aims to explain the basic principles of digital image acquisition, storage, manipulation and use, and the possibilities provided not only in research, but also in teaching and in routine diagnostic pathology. Images of natural objects are usually expressed digitally as 'bitmaps'--rectilinear arrays of small dots. The size of each dot can vary, but so can its information content in terms, for example, of colour, greyscale or opacity. Various file formats and compression algorithms are available. Video cameras connected to microscopes are familiar to most pathologists; video images can be converted directly to a digital form by a suitably equipped computer. Digital cameras and scanners are alternative acquisition tools of relevance to pathologists. Once acquired, a digital image can easily be subjected to the digital equivalent of any conventional darkroom manipulation and modern software allows much more flexibility, to such an extent that a new tool for scientific fraud has been created. For research, image enhancement and analysis is an increasingly powerful and affordable tool. Morphometric measurements are, after many predictions, at last beginning to be part of the toolkit of the diagnostic pathologist. In teaching, the potential to create dramatic yet informative presentations is demonstrated daily by the publishing industry; such methods are readily applicable to the classroom. The combination of digital images and the Internet raises many possibilities; for example, instead of seeking one expert diagnostic opinion, one could simultaneously seek the opinion of many, all around the globe. It is inevitable that in the coming years the use of digital images will spread from the laboratory to the medical curriculum and to the whole of diagnostic pathology.

  19. Spectroscopic imaging of limiter heat and particle fluxes and the resulting impurity sources during Wendelstein 7-X startup plasmas

    DOE PAGES

    Stephey, L.; Wurden, G. A.; Schmitz, O.; ...

    2016-08-08

    A combined IR and visible camera system [G. A. Wurden et al., “A high resolution IR/visible imaging system for the W7-X limiter,” Rev. Sci. Instrum. (these proceedings)] and a filterscope system [R. J. Colchin et al., Rev. Sci. Instrum. 74, 2068 (2003)] were implemented together to obtain spectroscopic data of limiter and first wall recycling and impurity sources during Wendelstein 7-X startup plasmas. Both systems together provided excellent temporal and spatial spectroscopic resolution of limiter 3. Narrowband interference filters in front of the camera yielded C-III and Hα photon flux, and the filterscope system provided H α, H β, He-I,more » He-II, C-II, and visible bremsstrahlung data. The filterscopes made additional measurements of several points on the W7-X vacuum vessel to yield wall recycling fluxes. Finally, the resulting photon flux from both the visible camera and filterscopes can then be compared to an EMC3-EIRENE synthetic diagnostic [H. Frerichs et al., “Synthetic plasma edge diagnostics for EMC3-EIRENE, highlighted for Wendelstein 7-X,” Rev. Sci. Instrum. (these proceedings)] to infer both a limiter particle flux and wall particle flux, both of which will ultimately be used to infer the complete particle balance and particle confinement time τ P.« less

  20. High-performance camera module for fast quality inspection in industrial printing applications

    NASA Astrophysics Data System (ADS)

    Fürtler, Johannes; Bodenstorfer, Ernst; Mayer, Konrad J.; Brodersen, Jörg; Heiss, Dorothea; Penz, Harald; Eckel, Christian; Gravogl, Klaus; Nachtnebel, Herbert

    2007-02-01

    Today, printing products which must meet highest quality standards, e.g., banknotes, stamps, or vouchers, are automatically checked by optical inspection systems. Typically, the examination of fine details of the print or security features demands images taken from various perspectives, with different spectral sensitivity (visible, infrared, ultraviolet), and with high resolution. Consequently, the inspection system is equipped with several cameras and has to cope with an enormous data rate to be processed in real-time. Hence, it is desirable to move image processing tasks into the camera to reduce the amount of data which has to be transferred to the (central) image processing system. The idea is to transfer relevant information only, i.e., features of the image instead of the raw image data from the sensor. These features are then further processed. In this paper a color line-scan camera for line rates up to 100 kHz is presented. The camera is based on a commercial CMOS (complementary metal oxide semiconductor) area image sensor and a field programmable gate array (FPGA). It implements extraction of image features which are well suited to detect print flaws like blotches of ink, color smears, splashes, spots and scratches. The camera design and several image processing methods implemented on the FPGA are described, including flat field correction, compensation of geometric distortions, color transformation, as well as decimation and neighborhood operations.

  1. A photoelastic modulator-based birefringence imaging microscope for measuring biological specimens

    NASA Astrophysics Data System (ADS)

    Freudenthal, John; Leadbetter, Andy; Wolf, Jacob; Wang, Baoliang; Segal, Solomon

    2014-11-01

    The photoelastic modulator (PEM) has been applied to a variety of polarimetric measurements. However, nearly all such applications use point-measurements where each point (spot) on the sample is measured one at a time. The main challenge for employing the PEM in a camera-based imaging instrument is that the PEM modulates too fast for typical cameras. The PEM modulates at tens of KHz. To capture the specific polarization information that is carried on the modulation frequency of the PEM, the camera needs to be at least ten times faster. However, the typical frame rates of common cameras are only in the tens or hundreds frames per second. In this paper, we report a PEM-camera birefringence imaging microscope. We use the so-called stroboscopic illumination method to overcome the incompatibility of the high frequency of the PEM to the relatively slow frame rate of a camera. We trigger the LED light source using a field-programmable gate array (FPGA) in synchrony with the modulation of the PEM. We show the measurement results of several standard birefringent samples as a part of the instrument calibration. Furthermore, we show results observed in two birefringent biological specimens, a human skin tissue that contains collagen and a slice of mouse brain that contains bundles of myelinated axonal fibers. Novel applications of this PEM-based birefringence imaging microscope to both research communities and industrial applications are being tested.

  2. A1C as a Diagnostic Criteria for Diabetes in Low- and Middle-Income Settings: Evidence from Peru

    PubMed Central

    Miranda, J. Jaime; Bernabe-Ortiz, Antonio; Stanojevic, Sanja; Malaga, German; Gilman, Robert H.; Smeeth, Liam

    2011-01-01

    Objectives To determine the prevalence of type 2 diabetes mellitus, in three groups of Peruvian adults, using fasting glucose and glycosylated hemoglobin (A1C). Methodology/Principal Findings This study included adults from the PERU MIGRANT Study who had fasted ≥8 h. Fasting glucose ≥126 mg/dL and A1C≥6.5% were used, separately, to define diabetes. Subjects with a current diagnosis of diabetes were excluded. 964 of 988 subjects were included in this analysis. Overall, 0.9% (95%CI 0.3–1.5) and 3.5% (95%CI 2.4–4.7) had diabetes using fasting glucose and A1C criteria, respectively. Compared to those classified as having diabetes using fasting glucose, newly classified subjects with diabetes using A1C (n = 25), were older, poorer, thinner and more likely to come from rural areas. Of these, 40% (10/25) had impaired fasting glucose (IFG). Conclusions This study shows that the use of A1C as diagnostic criteria for type 2 diabetes mellitus identifies people of different characteristics than fasting glucose. In the PERU MIGRANT population using A1C to define diabetes tripled the prevalence; the increase was more marked among poorer and rural populations. More than half the newly diagnosed people with diabetes using A1C had normal fasting glucose. PMID:21464957

  3. A1C as a diagnostic criteria for diabetes in low- and middle-income settings: evidence from Peru.

    PubMed

    Miranda, J Jaime; Bernabe-Ortiz, Antonio; Stanojevic, Sanja; Malaga, German; Gilman, Robert H; Smeeth, Liam

    2011-03-25

    To determine the prevalence of type 2 diabetes mellitus, in three groups of Peruvian adults, using fasting glucose and glycosylated hemoglobin (A1C). This study included adults from the PERU MIGRANT Study who had fasted ≥ 8 h. Fasting glucose ≥ 126 mg/dL and A1C ≥ 6.5% were used, separately, to define diabetes. Subjects with a current diagnosis of diabetes were excluded. 964 of 988 subjects were included in this analysis. Overall, 0.9% (95%CI 0.3-1.5) and 3.5% (95%CI 2.4-4.7) had diabetes using fasting glucose and A1C criteria, respectively. Compared to those classified as having diabetes using fasting glucose, newly classified subjects with diabetes using A1C (n = 25), were older, poorer, thinner and more likely to come from rural areas. Of these, 40% (10/25) had impaired fasting glucose (IFG). This study shows that the use of A1C as diagnostic criteria for type 2 diabetes mellitus identifies people of different characteristics than fasting glucose. In the PERU MIGRANT population using A1C to define diabetes tripled the prevalence; the increase was more marked among poorer and rural populations. More than half the newly diagnosed people with diabetes using A1C had normal fasting glucose.

  4. Real-time, T-ray imaging using a sub-terahertz gyrotron

    NASA Astrophysics Data System (ADS)

    Han, Seong-Tae; Torrezan, Antonio C.; Sirigiri, Jagadishwar R.; Shapiro, Michael A.; Temkin, Richard J.

    2012-06-01

    We demonstrated real-time, active, T-ray imaging using a 0.46 THz gyrotron capable of producing 16 W in continuous wave operation and a pyroelectric array camera with 124-by-124 pixels. An expanded Gaussian beam from the gyrotron was used to maintain the power density above the detection level of the pyroelectric array over the area of the irradiated object. Real-time imaging at a video rate of 48 Hz was achieved through the use of the built-in chopper of the camera. Potential applications include fast scanning for security purposes and for quality control of dry or frozen foods.

  5. A Planar Two-Dimensional Superconducting Bolometer Array for the Green Bank Telescope

    NASA Technical Reports Server (NTRS)

    Benford, Dominic; Staguhn, Johannes G.; Chervenak, James A.; Chen, Tina C.; Moseley, S. Harvey; Wollack, Edward J.; Devlin, Mark J.; Dicker, Simon R.; Supanich, Mark

    2004-01-01

    In order to provide high sensitivity rapid imaging at 3.3mm (90GHz) for the Green Bank Telescope - the world's largest steerable aperture - a camera is being built by the University of Pennsylvania, NASA/GSFC, and NRAO. The heart of this camera is an 8x8 close-packed, Nyquist-sampled detector array. We have designed and are fabricating a functional superconducting bolometer array system using a monolithic planar architecture. Read out by SQUID multiplexers, the superconducting transition edge sensors will provide fast, linear, sensitive response for high performance imaging. This will provide the first ever superconducting bolometer array on a facility instrument.

  6. 2D imaging X-ray diagnostic for measuring the current density distribution in a wide-area electron beam produced in a multiaperture diode with plasma cathode

    NASA Astrophysics Data System (ADS)

    Kurkuchekov, V.; Kandaurov, I.; Trunev, Y.

    2018-05-01

    A simple and inexpensive X-ray diagnostic tool was designed for measuring the cross-sectional current density distribution in a low-relativistic pulsed electron beam produced in a source based on an arc-discharge plasma cathode and multiaperture diode-type electron optical system. The beam parameters were as follows: Uacc = 50–110 kV, Ibeam = 20–100 A, τbeam = 0.1–0.3 ms. The beam effective diameter was ca. 7 cm. Based on a pinhole camera, the diagnostic allows one to obtain a 2D profile of electron beam flux distribution on a flat metal target in a single shot. The linearity of the diagnostic system response to the electron flux density was established experimentally. Spatial resolution of the diagnostic was also estimated in special test experiments. The optimal choice of the main components of the diagnostic technique is discussed.

  7. Calcium neuroimaging in behaving zebrafish larvae using a turn-key light field camera

    NASA Astrophysics Data System (ADS)

    Cruz Perez, Carlos; Lauri, Antonella; Symvoulidis, Panagiotis; Cappetta, Michele; Erdmann, Arne; Westmeyer, Gil Gregor

    2015-09-01

    Reconstructing a three-dimensional scene from multiple simultaneously acquired perspectives (the light field) is an elegant scanless imaging concept that can exceed the temporal resolution of currently available scanning-based imaging methods for capturing fast cellular processes. We tested the performance of commercially available light field cameras on a fluorescent microscopy setup for monitoring calcium activity in the brain of awake and behaving reporter zebrafish larvae. The plenoptic imaging system could volumetrically resolve diverse neuronal response profiles throughout the zebrafish brain upon stimulation with an aversive odorant. Behavioral responses of the reporter fish could be captured simultaneously together with depth-resolved neuronal activity. Overall, our assessment showed that with some optimizations for fluorescence microscopy applications, commercial light field cameras have the potential of becoming an attractive alternative to custom-built systems to accelerate molecular imaging research on cellular dynamics.

  8. Calcium neuroimaging in behaving zebrafish larvae using a turn-key light field camera.

    PubMed

    Perez, Carlos Cruz; Lauri, Antonella; Symvoulidis, Panagiotis; Cappetta, Michele; Erdmann, Arne; Westmeyer, Gil Gregor

    2015-09-01

    Reconstructing a three-dimensional scene from multiple simultaneously acquired perspectives (the light field) is an elegant scanless imaging concept that can exceed the temporal resolution of currently available scanning-based imaging methods for capturing fast cellular processes. We tested the performance of commercially available light field cameras on a fluorescent microscopy setup for monitoring calcium activity in the brain of awake and behaving reporter zebrafish larvae. The plenoptic imaging system could volumetrically resolve diverse neuronal response profiles throughout the zebrafish brain upon stimulation with an aversive odorant. Behavioral responses of the reporter fish could be captured simultaneously together with depth-resolved neuronal activity. Overall, our assessment showed that with some optimizations for fluorescence microscopy applications, commercial light field cameras have the potential of becoming an attractive alternative to custom-built systems to accelerate molecular imaging research on cellular dynamics.

  9. Deflection Measurements of a Thermally Simulated Nuclear Core Using a High-Resolution CCD-Camera

    NASA Technical Reports Server (NTRS)

    Stanojev, B. J.; Houts, M.

    2004-01-01

    Space fission systems under consideration for near-term missions all use compact. fast-spectrum reactor cores. Reactor dimensional change with increasing temperature, which affects neutron leakage. is the dominant source of reactivity feedback in these systems. Accurately measuring core dimensional changes during realistic non-nuclear testing is therefore necessary in predicting the system nuclear equivalent behavior. This paper discusses one key technique being evaluated for measuring such changes. The proposed technique is to use a Charged Couple Device (CCD) sensor to obtain deformation readings of electrically heated prototypic reactor core geometry. This paper introduces a technique by which a single high spatial resolution CCD camera is used to measure core deformation in Real-Time (RT). Initial system checkout results are presented along with a discussion on how additional cameras could be used to achieve a three- dimensional deformation profile of the core during test.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patankar, S.; Gumbrell, E. T.; Robinson, T. S.

    Here we report a new method using high stability, laser-driven supercontinuum generation in a liquid cell to calibrate the absolute photon response of fast optical streak cameras as a function of wavelength when operating at fastest sweep speeds. A stable, pulsed white light source based around the use of self-phase modulation in a salt solution was developed to provide the required brightness on picosecond timescales, enabling streak camera calibration in fully dynamic operation. The measured spectral brightness allowed for absolute photon response calibration over a broad spectral range (425-650nm). Calibrations performed with two Axis Photonique streak cameras using the Photonismore » P820PSU streak tube demonstrated responses which qualitatively follow the photocathode response. Peak sensitivities were 1 photon/count above background. The absolute dynamic sensitivity is less than the static by up to an order of magnitude. We attribute this to the dynamic response of the phosphor being lower.« less

  11. Performance of the prototype LaBr{sub 3} spectrometer developed for the JET gamma-ray camera upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rigamonti, D., E-mail: davide.rigamonti@mib.infn.it; Nocente, M.; Gorini, G.

    2016-11-15

    In this work, we describe the solution developed by the gamma ray camera upgrade enhancement project to improve the spectroscopic properties of the existing JET γ-ray camera. Aim of the project is to enable gamma-ray spectroscopy in JET deuterium-tritium plasmas. A dedicated pilot spectrometer based on a LaBr{sub 3} crystal coupled to a silicon photo-multiplier has been developed. A proper pole zero cancellation network able to shorten the output signal to a length of 120 ns has been implemented allowing for spectroscopy at MHz count rates. The system has been characterized in the laboratory and shows an energy resolution ofmore » 5.5% at E{sub γ} = 0.662 MeV, which extrapolates favorably in the energy range of interest for gamma-ray emission from fast ions in fusion plasmas.« less

  12. Design optimisation of a TOF-based collimated camera prototype for online hadrontherapy monitoring

    NASA Astrophysics Data System (ADS)

    Pinto, M.; Dauvergne, D.; Freud, N.; Krimmer, J.; Letang, J. M.; Ray, C.; Roellinghoff, F.; Testa, E.

    2014-12-01

    Hadrontherapy is an innovative radiation therapy modality for which one of the main key advantages is the target conformality allowed by the physical properties of ion species. However, in order to maximise the exploitation of its potentialities, online monitoring is required in order to assert the treatment quality, namely monitoring devices relying on the detection of secondary radiations. Herein is presented a method based on Monte Carlo simulations to optimise a multi-slit collimated camera employing time-of-flight selection of prompt-gamma rays to be used in a clinical scenario. In addition, an analytical tool is developed based on the Monte Carlo data to predict the expected precision for a given geometrical configuration. Such a method follows the clinical workflow requirements to simultaneously have a solution that is relatively accurate and fast. Two different camera designs are proposed, considering different endpoints based on the trade-off between camera detection efficiency and spatial resolution to be used in a proton therapy treatment with active dose delivery and assuming a homogeneous target.

  13. Driving techniques for high frame rate CCD camera

    NASA Astrophysics Data System (ADS)

    Guo, Weiqiang; Jin, Longxu; Xiong, Jingwu

    2008-03-01

    This paper describes a high-frame rate CCD camera capable of operating at 100 frames/s. This camera utilizes Kodak KAI-0340, an interline transfer CCD with 640(vertical)×480(horizontal) pixels. Two output ports are used to read out CCD data and pixel rates approaching 30 MHz. Because of its reduced effective opacity of vertical charge transfer registers, interline transfer CCD can cause undesired image artifacts, such as random white spots and smear generated in the registers. To increase frame rate, a kind of speed-up structure has been incorporated inside KAI-0340, then it is vulnerable to a vertical stripe effect. The phenomena which mentioned above may severely impair the image quality. To solve these problems, some electronic methods of eliminating these artifacts are adopted. Special clocking mode can dump the unwanted charge quickly, then the fast readout of the images, cleared of smear, follows immediately. Amplifier is used to sense and correct delay mismatch between the dual phase vertical clock pulses, the transition edges become close to coincident, so vertical stripes disappear. Results obtained with the CCD camera are shown.

  14. Visual fatigue modeling for stereoscopic video shot based on camera motion

    NASA Astrophysics Data System (ADS)

    Shi, Guozhong; Sang, Xinzhu; Yu, Xunbo; Liu, Yangdong; Liu, Jing

    2014-11-01

    As three-dimensional television (3-DTV) and 3-D movie become popular, the discomfort of visual feeling limits further applications of 3D display technology. The cause of visual discomfort from stereoscopic video conflicts between accommodation and convergence, excessive binocular parallax, fast motion of objects and so on. Here, a novel method for evaluating visual fatigue is demonstrated. Influence factors including spatial structure, motion scale and comfortable zone are analyzed. According to the human visual system (HVS), people only need to converge their eyes to the specific objects for static cameras and background. Relative motion should be considered for different camera conditions determining different factor coefficients and weights. Compared with the traditional visual fatigue prediction model, a novel visual fatigue predicting model is presented. Visual fatigue degree is predicted using multiple linear regression method combining with the subjective evaluation. Consequently, each factor can reflect the characteristics of the scene, and the total visual fatigue score can be indicated according to the proposed algorithm. Compared with conventional algorithms which ignored the status of the camera, our approach exhibits reliable performance in terms of correlation with subjective test results.

  15. Efficient fault diagnosis of helicopter gearboxes

    NASA Technical Reports Server (NTRS)

    Chin, H.; Danai, K.; Lewicki, D. G.

    1993-01-01

    Application of a diagnostic system to a helicopter gearbox is presented. The diagnostic system is a nonparametric pattern classifier that uses a multi-valued influence matrix (MVIM) as its diagnostic model and benefits from a fast learning algorithm that enables it to estimate its diagnostic model from a small number of measurement-fault data. To test this diagnostic system, vibration measurements were collected from a helicopter gearbox test stand during accelerated fatigue tests and at various fault instances. The diagnostic results indicate that the MVIM system can accurately detect and diagnose various gearbox faults so long as they are included in training.

  16. Overview of the FTU results

    NASA Astrophysics Data System (ADS)

    Pucella, G.; Alessi, E.; Amicucci, L.; Angelini, B.; Apicella, M. L.; Apruzzese, G.; Artaserse, G.; Belli, F.; Bin, W.; Boncagni, L.; Botrugno, A.; Briguglio, S.; Bruschi, A.; Buratti, P.; Calabrò, G.; Cappelli, M.; Cardinali, A.; Castaldo, C.; Causa, F.; Ceccuzzi, S.; Centioli, C.; Cesario, R.; Cianfarani, C.; Claps, G.; Cocilovo, V.; Cordella, F.; Crisanti, F.; D'Arcangelo, O.; De Angeli, M.; Di Troia, C.; Esposito, B.; Farina, D.; Figini, L.; Fogaccia, G.; Frigione, D.; Fusco, V.; Gabellieri, L.; Garavaglia, S.; Giovannozzi, E.; Granucci, G.; Iafrati, M.; Iannone, F.; Lontano, M.; Maddaluno, G.; Magagnino, S.; Marinucci, M.; Marocco, D.; Mazzitelli, G.; Mazzotta, C.; Milovanov, A.; Minelli, D.; Mirizzi, F. C.; Moro, A.; Nowak, S.; Pacella, D.; Panaccione, L.; Panella, M.; Pericoli-Ridolfini, V.; Pizzuto, A.; Podda, S.; Ramogida, G.; Ravera, G.; Ricci, D.; Romano, A.; Sozzi, C.; Tuccillo, A. A.; Tudisco, O.; Viola, B.; Vitale, V.; Vlad, G.; Zerbini, M.; Zonca, F.; Aquilini, M.; Cefali, P.; Di Ferdinando, E.; Di Giovenale, S.; Giacomi, G.; Grosso, A.; Mellera, V.; Mezzacappa, M.; Pensa, A.; Petrolini, P.; Piergotti, V.; Raspante, B.; Rocchi, G.; Sibio, A.; Tilia, B.; Tulli, R.; Vellucci, M.; Zannetti, D.; Bogdanovic-Radovic, I.; Carnevale, D.; Casolari, A.; Ciotti, M.; Conti, C.; Dinca, P. P.; Dolci, V.; Galperti, C.; Gospodarczyk, M.; Grosso, G.; Lubiako, L.; Lungu, M.; Martin-Solis, J. R.; Meineri, C.; Murtas, F.; Nardone, A.; Orsitto, F. P.; Perelli Cippo, E.; Popovic, Z.; Ripamonti, D.; Simonetto, A.; Tartari, U.

    2017-10-01

    Experiments on runaway electrons have been performed for the determination of the critical electric field for runaway generation. A large database of post-disruption runaway beams has been analyzed in order to identify linear dynamical models for new position and current runaway beam controllers, and experiments of electron cyclotron assisted plasma start-up have shown the presence of runaway electrons also below the expected electric field threshold, indicating that the radio-frequency power acts as seeding for fast electrons. A linear micro-stability analysis of neon-doped pulses has been carried out to investigate the mechanisms leading to the observed density peaking. A study of the ion drift effects on the MARFE instability has been performed and the peaking of density profile in the high density regime has been well reproduced using a thermo-diffusive pinch in the particle transport equation. The study of the density limit performed in the past has been extended towards lower values of toroidal magnetic field and plasma current. The analysis of the linear stability of the 2/1 tearing mode observed in high density plasmas has highlighted a destabilization with increasing peaking of the current profile during the density ramp-up, while the final phase of the mode temporal evolution is characterized by limit cycles on the amplitude/frequency plane. A liquid lithium limiter with thermal load capability up to 10 MW m-2 has been tested. The pulse duration has been extended up to 4.5 s and elongated configurations have been obtained for 3.5 s, with the X-point just outside the plasma chamber. A W/Fe sample has been exposed in the scrape-off layer in order to study the sputtering of Fe and the W enrichment of the surface layer. Dusts have been collected and analyzed, showing that the metallic population exhibits a high fraction of magnetic grains. A new diagnostic for in-flight runaway electron studies has allowed the image and the visible/infrared spectrum of the forward and backward synchrotron radiation to be provided simultaneously. A fast infrared camera for thermo-graphic analysis has provided the pattern of the toroidal limiter heating by disruption heat loads, and a triple-GEM detector has been tested for soft x-ray diagnostics. The collective Thomson scattering diagnostic has been upgraded and used for investigations on parametric decay instability excitation by electron cyclotron beams correlated with magnetic islands, and new capabilities of the Cherenkov probe have been explored in the presence of beta-induced Alfvén eigenmodes associated to high amplitude magnetic islands.

  17. The experiences of health-related quality of life in patients with nonspecific symptoms who undergo a diagnostic evaluation for cancer: a qualitative interview study.

    PubMed

    Moseholm, Ellen; Lindhardt, Bjarne Oerskov; Rydahl-Hansen, Susan

    2017-09-01

    The diagnostic phase of cancer can affect health-related quality of life (HRQoL). The aim of this study was to investigate how patients with nonspecific symptoms experience HRQoL while undergoing diagnostic evaluations for cancer. Twenty-one participants who had completed a fast-track evaluation for possible cancer at one of three hospitals in the Capital Region, Denmark were interviewed 2-4 weeks after completing diagnostic evaluations. The interviews were semi-structured and were supported by an interview guide based on the same themes as in The European Organisation for Research and Treatment of Cancer Quality of Life questionnaire (EORCT-QLQ-C30). Data analysis was based on qualitative content analysis by Krippendorff. The analysis generated six categories: symptoms, physical-, role-, emotional-, cognitive- and social functioning, and the diagnostic fast-track experience. From these categories, a main theme was identified: Health-related quality of life is not solely affected by the diagnostic process. The results provide a comprehensive understanding of HRQoL in the diagnostic phase of possible cancer, which can be used not only to enhance evidence-based care, but also in the interpretation of the EORTC-QLQ-C30 scores. Psycho-social support with a focus on individual informational needs during the diagnostic phase may be warranted. © 2016 Nordic College of Caring Science.

  18. 4D laser camera for accurate patient positioning, collision avoidance, image fusion and adaptive approaches during diagnostic and therapeutic procedures.

    PubMed

    Brahme, Anders; Nyman, Peter; Skatt, Björn

    2008-05-01

    A four-dimensional (4D) laser camera (LC) has been developed for accurate patient imaging in diagnostic and therapeutic radiology. A complementary metal-oxide semiconductor camera images the intersection of a scanned fan shaped laser beam with the surface of the patient and allows real time recording of movements in a three-dimensional (3D) or four-dimensional (4D) format (3D +time). The LC system was first designed as an accurate patient setup tool during diagnostic and therapeutic applications but was found to be of much wider applicability as a general 4D photon "tag" for the surface of the patient in different clinical procedures. It is presently used as a 3D or 4D optical benchmark or tag for accurate delineation of the patient surface as demonstrated for patient auto setup, breathing and heart motion detection. Furthermore, its future potential applications in gating, adaptive therapy, 3D or 4D image fusion between most imaging modalities and image processing are discussed. It is shown that the LC system has a geometrical resolution of about 0, 1 mm and that the rigid body repositioning accuracy is about 0, 5 mm below 20 mm displacements, 1 mm below 40 mm and better than 2 mm at 70 mm. This indicates a slight need for repeated repositioning when the initial error is larger than about 50 mm. The positioning accuracy with standard patient setup procedures for prostate cancer at Karolinska was found to be about 5-6 mm when independently measured using the LC system. The system was found valuable for positron emission tomography-computed tomography (PET-CT) in vivo tumor and dose delivery imaging where it potentially may allow effective correction for breathing artifacts in 4D PET-CT and image fusion with lymph node atlases for accurate target volume definition in oncology. With a LC system in all imaging and radiation therapy rooms, auto setup during repeated diagnostic and therapeutic procedures may save around 5 min per session, increase accuracy and allow efficient image fusion between all imaging modalities employed.

  19. Emergency ultrasound-based algorithms for diagnosing blunt abdominal trauma.

    PubMed

    Stengel, Dirk; Rademacher, Grit; Ekkernkamp, Axel; Güthoff, Claas; Mutze, Sven

    2015-09-14

    Ultrasonography (performed by means of a four-quadrant, focused assessment of sonography for trauma (FAST)) is regarded as a key instrument for the initial assessment of patients with suspected blunt abdominal and thoraco-abdominal trauma in the emergency department setting. FAST has a high specificity but low sensitivity in detecting and excluding visceral injuries. Proponents of FAST argue that ultrasound-based clinical pathways enhance the speed of primary trauma assessment, reduce the number of unnecessary multi-detector computed tomography (MDCT) scans, and enable quicker triage to surgical and non-surgical care. Given the proven accuracy, increasing availability of, and indication for, MDCT among patients with blunt abdominal and multiple injuries, we aimed to compile the best available evidence of the use of FAST-based assessment compared with other primary trauma assessment protocols. To assess the effects of diagnostic algorithms using ultrasonography including in FAST examinations in the emergency department in relation to the early, late, and overall mortality of patients with suspected blunt abdominal trauma. The most recent search was run on 30th June 2015. We searched the Cochrane Injuries Group Specialised Register, The Cochrane Library, MEDLINE (OvidSP), EMBASE (OvidSP), ISI Web of Science (SCI-EXPANDED, SSCI, CPCI-S, and CPSI-SSH), clinical trials registers, and screened reference lists. Trial authors were contacted for further information and individual patient data. We included randomised controlled trials (RCTs). Participants were patients with blunt torso, abdominal, or multiple trauma undergoing diagnostic investigations for abdominal organ injury. The intervention was diagnostic algorithms comprising emergency ultrasonography (US). The control was diagnostic algorithms without US examinations (for example, primary computed tomography (CT) or diagnostic peritoneal lavage (DPL)). Outcomes were mortality, use of CT or invasive procedures (DPL, laparoscopy, laparotomy), and cost-effectiveness. Two authors (DS and CG) independently selected trials for inclusion, assessed methodological quality, and extracted data. Methodological quality was assessed using the Cochrane Collaboration risk of bias tool. Where possible, data were pooled and relative risks (RRs), risk differences (RDs), and weighted mean differences, each with 95% confidence intervals (CIs), were calculated by fixed-effect or random-effects models as appropriate. We identified four studies meeting our inclusion criteria. Overall, trials were of poor to moderate methodological quality. Few trial authors responded to our written inquiries seeking to resolve controversial issues and to obtain individual patient data. Strong heterogeneity amongst the trials prompted discussion between the review authors as to whether the data should or should not be pooled; we decided in favour of a quantitative synthesis to provide a rough impression about the effect sizes achievable with US-based triage algorithms. We pooled mortality data from three trials involving 1254 patients; the RR in favour of the FAST arm was 1.00 (95% CI 0.50 to 2.00). FAST-based pathways reduced the number of CT scans (random-effects model RD -0.52, 95% CI -0.83 to -0.21), but the meaning of this result was unclear. The experimental evidence justifying FAST-based clinical pathways in diagnosing patients with suspected abdominal or multiple blunt trauma remains poor. Because of strong heterogeneity between the trial results, the quantitative information provided by this review may only be used in an exploratory fashion. It is unlikely that FAST will ever be investigated by means of a confirmatory, large-scale RCT in the future. Thus, this Cochrane Review may be regarded as a review which provides the best available evidence for clinical practice guidelines and management recommendations. It can only be concluded from the few head-to-head studies that negative US scans are likely to reduce the incidence of MDCT scans which, given the low sensitivity of FAST (or reliability of negative results), may adversely affect the diagnostic yield of the trauma survey. At best, US has no negative impact on mortality or morbidity. Assuming that major blunt abdominal or multiple trauma is associated with 15% mortality and a CT-based diagnostic work-up is considered the current standard of care, 874, 3495, or 21,838 patients are needed per intervention group to demonstrate non-inferiority of FAST to CT-based algorithms with non-inferiority margins of 5%, 2.5%, and 1%, power of 90%, and a type-I error alpha of 5%.

  20. Velocity space resolved absolute measurement of fast ion losses induced by a tearing mode in the ASDEX Upgrade tokamak

    NASA Astrophysics Data System (ADS)

    Galdon-Quiroga, J.; Garcia-Munoz, M.; Sanchis-Sanchez, L.; Mantsinen, M.; Fietz, S.; Igochine, V.; Maraschek, M.; Rodriguez-Ramos, M.; Sieglin, B.; Snicker, A.; Tardini, G.; Vezinet, D.; Weiland, M.; Eriksson, L. G.; The ASDEX Upgrade Team; The EUROfusion MST1 Team

    2018-03-01

    Absolute flux of fast ion losses induced by tearing modes have been measured by means of fast ion loss detectors (FILD) for the first time in RF heated plasmas in the ASDEX Upgrade tokamak. Up to 30 MW m-2 of fast ion losses are measured by FILD at 5 cm from the separatrix, consistent with infra-red camera measurements, with energies in the range of 250-500 keV and pitch angles corresponding to large trapped orbits. A resonant interaction between the fast ions in the high energy tail of the ICRF distribution and a m/n  =  5/4 tearing mode leads to enhanced fast ion losses. Around 9.3 +/- 0.7 % of the fast ion losses are found to be coherent with the mode and scale linearly with its amplitude, indicating the convective nature of the transport mechanism. Simulations have been carried out to estimate the contribution of the prompt losses. A good agreement is found between the simulated and the measured velocity space of the losses. The velocity space resonances that may be responsible for the enhanced fast ion losses are identified.

  1. Device for wavelength-selective imaging

    DOEpatents

    Frangioni, John V.

    2010-09-14

    An imaging device captures both a visible light image and a diagnostic image, the diagnostic image corresponding to emissions from an imaging medium within the object. The visible light image (which may be color or grayscale) and the diagnostic image may be superimposed to display regions of diagnostic significance within a visible light image. A number of imaging media may be used according to an intended application for the imaging device, and an imaging medium may have wavelengths above, below, or within the visible light spectrum. The devices described herein may be advantageously packaged within a single integrated device or other solid state device, and/or employed in an integrated, single-camera medical imaging system, as well as many non-medical imaging systems that would benefit from simultaneous capture of visible-light wavelength images along with images at other wavelengths.

  2. Underwater Test Diagnostics Using Explosively Excited Argon And Laser Light Photography Techniques

    NASA Astrophysics Data System (ADS)

    Wisotski, John

    1990-01-01

    This paper presents results of photographic methods employed in underwater tests used to study high-velocity fragment deceleration, deformation and fracture during the perforation of water-backed plates. These methods employed overlapping ultra-high and very high speed camera recordings using explosively excited argon and ruby-laser light sources that gave ample light to penetrate across a 2.3-meter (7.54-foot) diameter tank of water with enough intensity to photograph displacement-time histories of steel cubes with impact speeds of 1000 to 1500 m/s (3280 to 4920 ft/s) at camera framing rates of 250,000 and 17,000 fr/s, respectively.

  3. Improving the off-axis spatial resolution and dynamic range of the NIF X-ray streak cameras (invited)

    DOE PAGES

    MacPhee, A. G.; Dymoke-Bradshaw, A. K. L.; Hares, J. D.; ...

    2016-08-08

    Here, we report simulationsand experiments that demonstrate an increasein spatial resolution ofthe NIF core diagnostic x-ray streak camerasby a factor of two, especially off axis. A designwas achieved by usinga corrector electron optic to flatten the field curvature at the detector planeand corroborated by measurement. In addition, particle in cell simulations were performed to identify theregions in the streak camera that contribute most to space charge blurring. Our simulations provide a tool for convolving syntheticpre-shot spectra with the instrument functionso signal levels can be set to maximize dynamic range for the relevant part of the streak record.

  4. International Congress on High Speed Photography and Photonics, 17th, Pretoria, Republic of South Africa, Sept. 1-5, 1986, Proceedings. Volumes 1 & 2

    NASA Astrophysics Data System (ADS)

    McDowell, M. W.; Hollingworth, D.

    1986-01-01

    The present conference discusses topics in mining applications of high speed photography, ballistic, shock wave and detonation studies employing high speed photography, laser and X-ray diagnostics, biomechanical photography, millisec-microsec-nanosec-picosec-femtosec photographic methods, holographic, schlieren, and interferometric techniques, and videography. Attention is given to such issues as the pulse-shaping of ultrashort optical pulses, the performance of soft X-ray streak cameras, multiple-frame image tube operation, moire-enlargement motion-raster photography, two-dimensional imaging with tomographic techniques, photochron TV streak cameras, and streak techniques in detonics.

  5. High energy X-ray pinhole imaging at the Z facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McPherson, L. Armon; Ampleford, David J.; Coverdale, Christine A.

    A new high photon energy (hv > 15 keV) time-integrated pinhole camera (TIPC) has become available at the Z facility for diagnostic applications. This camera employs five pinholes in a linear array for recording five images at once onto an image plate detector. Each pinhole may be independently filtered to yield five different spectral responses. The pinhole array is fabricated from a 1-cm thick tungsten block and is available with either straight pinholes or conical pinholes. Each pinhole within the array block is 250 μm in diameter. The five pinholes are splayed with respect to each other such that theymore » point to the same location in space, and hence present the same view of the target load at the Z facility. The fielding distance is 66 cm and the nominal image magnification is 0.374. Initial experimental results are shown to illustrate the performance of the camera.« less

  6. High energy X-ray pinhole imaging at the Z facility

    DOE PAGES

    McPherson, L. Armon; Ampleford, David J.; Coverdale, Christine A.; ...

    2016-06-06

    A new high photon energy (hv > 15 keV) time-integrated pinhole camera (TIPC) has become available at the Z facility for diagnostic applications. This camera employs five pinholes in a linear array for recording five images at once onto an image plate detector. Each pinhole may be independently filtered to yield five different spectral responses. The pinhole array is fabricated from a 1-cm thick tungsten block and is available with either straight pinholes or conical pinholes. Each pinhole within the array block is 250 μm in diameter. The five pinholes are splayed with respect to each other such that theymore » point to the same location in space, and hence present the same view of the target load at the Z facility. The fielding distance is 66 cm and the nominal image magnification is 0.374. Initial experimental results are shown to illustrate the performance of the camera.« less

  7. Fast demodulation of pattern images by spiral phase transform in structured-illumination reflectance imaging for detection of bruises in apples

    USDA-ARS?s Scientific Manuscript database

    A structured-illumination reflectance imaging (SIRI) system was recently developed in our laboratory for enhanced quality evaluation of horticultural products. It was implemented using a digital camera to acquire reflectance images from food products subjected to sinusoidal patterns (or other simila...

  8. Faster than "g", Revisited with High-Speed Imaging

    ERIC Educational Resources Information Center

    Vollmer, Michael; Mollmann, Klaus-Peter

    2012-01-01

    The introduction of modern high-speed cameras in physics teaching provides a tool not only for easy visualization, but also for quantitative analysis of many simple though fast occurring phenomena. As an example, we present a very well-known demonstration experiment--sometimes also discussed in the context of falling chimneys--which is commonly…

  9. Measuring Effects Of Lightning On Power And Telephone Lines

    NASA Technical Reports Server (NTRS)

    Jafferis, William; Thompson, E. M.; Medelius, P.; Rubinstein, M.; Tzeng, A.

    1992-01-01

    Spherical antenna senses both horizontal and vertical fields simultaneously. Measures "fast" components of electric field used in conjunction with other equipment, including antenna measuring "slow" vertical component of electric field; microphone that senses thunder; cameras making visual records, which locate lightning; magnetic-field sensor; optical sensors; and instruments measuring speed and direction of wind.

  10. Projection of controlled repeatable real-time moving targets to test and evaluate motion imagery quality

    NASA Astrophysics Data System (ADS)

    Scopatz, Stephen D.; Mendez, Michael; Trent, Randall

    2015-05-01

    The projection of controlled moving targets is key to the quantitative testing of video capture and post processing for Motion Imagery. This presentation will discuss several implementations of target projectors with moving targets or apparent moving targets creating motion to be captured by the camera under test. The targets presented are broadband (UV-VIS-IR) and move in a predictable, repeatable and programmable way; several short videos will be included in the presentation. Among the technical approaches will be targets that move independently in the camera's field of view, as well targets that change size and shape. The development of a rotating IR and VIS 4 bar target projector with programmable rotational velocity and acceleration control for testing hyperspectral cameras is discussed. A related issue for motion imagery is evaluated by simulating a blinding flash which is an impulse of broadband photons in fewer than 2 milliseconds to assess the camera's reaction to a large, fast change in signal. A traditional approach of gimbal mounting the camera in combination with the moving target projector is discussed as an alternative to high priced flight simulators. Based on the use of the moving target projector several standard tests are proposed to provide a corresponding test to MTF (resolution), SNR and minimum detectable signal at velocity. Several unique metrics are suggested for Motion Imagery including Maximum Velocity Resolved (the measure of the greatest velocity that is accurately tracked by the camera system) and Missing Object Tolerance (measurement of tracking ability when target is obscured in the images). These metrics are applicable to UV-VIS-IR wavelengths and can be used to assist in camera and algorithm development as well as comparing various systems by presenting the exact scenes to the cameras in a repeatable way.

  11. Numerical Simulations of Thick Aluminum Wire Behavior Under Megampere Current Drive

    DTIC Science & Technology

    2009-06-01

    time dependences of the wire radii agree rather well with the experimental results obtained using laser diagnostics and light imaging. The...simulated time dependences of the wire radii agree rather well with the experimental results obtained using laser diagnostics and light imaging. The...experiments involved a wide range of diagnostics , including current probes, streaked imaging of optical emission, 4-frame laser shadowgraphy, fast

  12. Fast reconstruction of optical properties for complex segmentations in near infrared imaging

    NASA Astrophysics Data System (ADS)

    Jiang, Jingjing; Wolf, Martin; Sánchez Majos, Salvador

    2017-04-01

    The intrinsic ill-posed nature of the inverse problem in near infrared imaging makes the reconstruction of fine details of objects deeply embedded in turbid media challenging even for the large amounts of data provided by time-resolved cameras. In addition, most reconstruction algorithms for this type of measurements are only suitable for highly symmetric geometries and rely on a linear approximation to the diffusion equation since a numerical solution of the fully non-linear problem is computationally too expensive. In this paper, we will show that a problem of practical interest can be successfully addressed making efficient use of the totality of the information supplied by time-resolved cameras. We set aside the goal of achieving high spatial resolution for deep structures and focus on the reconstruction of complex arrangements of large regions. We show numerical results based on a combined approach of wavelength-normalized data and prior geometrical information, defining a fully parallelizable problem in arbitrary geometries for time-resolved measurements. Fast reconstructions are obtained using a diffusion approximation and Monte-Carlo simulations, parallelized in a multicore computer and a GPU respectively.

  13. Plasma formation in water vapour layers in high conductivity liquids

    NASA Astrophysics Data System (ADS)

    Kelsey, C. P.; Schaper, L.; Stalder, K. R.; Graham, W. G.

    2011-10-01

    The vapour layer development stage of relatively low voltage plasmas in conducting solutions has already been well explored. The nature of the discharges formed within the vapour layer however is still largely unexplored. Here we examine the nature of such discharges through a combination of fast imaging and spatially, temporally resolved spectroscopy and electrical characterisation. The experimental setup used is a pin-to-plate discharge configuration with a -350V, 200 μs pulse applied at a repetition rate of 2Hz. A lens, followed by beam splitter allows beams to one Andor ICCD camera to capture images of the plasma emission with a second camera at the exit of a high resolution spectrometer. Through synchronization of the camera images at specified times after plasma ignition (as determined from current-voltage characteristics) they can be correlated with the spectra features. Initial measurements reveal two apparently different plasma formations. Stark broadening of the hydrogen Balmer beta line indicate electron densities of 3 to 5 ×1020 m-3 for plasmas produced early in the voltage pulse and an order of magnitude less for the later plasmas. The vapour layer development stage of relatively low voltage plasmas in conducting solutions has already been well explored. The nature of the discharges formed within the vapour layer however is still largely unexplored. Here we examine the nature of such discharges through a combination of fast imaging and spatially, temporally resolved spectroscopy and electrical characterisation. The experimental setup used is a pin-to-plate discharge configuration with a -350V, 200 μs pulse applied at a repetition rate of 2Hz. A lens, followed by beam splitter allows beams to one Andor ICCD camera to capture images of the plasma emission with a second camera at the exit of a high resolution spectrometer. Through synchronization of the camera images at specified times after plasma ignition (as determined from current-voltage characteristics) they can be correlated with the spectra features. Initial measurements reveal two apparently different plasma formations. Stark broadening of the hydrogen Balmer beta line indicate electron densities of 3 to 5 ×1020 m-3 for plasmas produced early in the voltage pulse and an order of magnitude less for the later plasmas. Colin Kelsey is supported by a DEL NI PhD studentship.

  14. Shifting from glucose diagnostic criteria to the new HbA(1c) criteria would have a profound impact on prevalence of diabetes among a high-risk Spanish population.

    PubMed

    Costa, B; Barrio, F; Cabré, J-J; Piñol, J-L; Cos, F-X; Solé, C; Bolibar, B; Castell, C; Lindström, J; Barengo, N; Tuomilehto, J

    2011-10-01

    To investigate changes in the prevalence of diabetes and pre-diabetes by shifting from 2-h plasma glucose and/or fasting plasma glucose diagnostic criteria to the proposed new HbA(1c) -based criteria when applied to a Mediterranean population detected to have a high risk of Type 2 diabetes. Individuals without diabetes aged 45-75 years (n = 2287) were screened using the Finnish Diabetes Risk Score questionnaire, a 2-h oral glucose tolerance test plus HbA(1c) test. Prevalence and degree of diagnostic overlap between three sets of criteria (2-h plasma glucose, fasting plasma glucose and HbA(1c) ) and three diagnostic categories (normal, pre-diabetes and diabetes) were calculated. Defining diabetes by a single HbA(1c) measurement resulted in a dramatic decrease in prevalence (1.3%), particularly in comparison with diabetes defined by 2-h plasma glucose (8.6%), but was also significant with regard to fasting plasma glucose (2.8%). A total of 201 screened subjects (8.8%) were classified as having diabetes and 1023 (44.7%) as having pre-diabetes based on at least one of these criteria; among these, the presence of all three criteria simultaneously classified only 21 and 110 individuals respectively, about ten percent of each group. The single overlap index between subjects diagnosed as having diabetes by 2-h plasma glucose/fasting plasma glucose vs. HbA(1c) was 13.9/28%. Similarly, the single overlap index regarding pre-diabetes was 19.2/27.1%. A shift from the glucose-based diagnosis to the HbA(1c) -based diagnosis for diabetes will reduce diabetes prevalence with a low overall or single degree of overlap between diagnostic categories in this high-risk Spanish population. © 2011 The Authors. Diabetic Medicine © 2011 Diabetes UK.

  15. 3D palmprint data fast acquisition and recognition

    NASA Astrophysics Data System (ADS)

    Wang, Xiaoxu; Huang, Shujun; Gao, Nan; Zhang, Zonghua

    2014-11-01

    This paper presents a fast 3D (Three-Dimension) palmprint capturing system and develops an efficient 3D palmprint feature extraction and recognition method. In order to fast acquire accurate 3D shape and texture of palmprint, a DLP projector triggers a CCD camera to realize synchronization. By generating and projecting green fringe pattern images onto the measured palm surface, 3D palmprint data are calculated from the fringe pattern images. The periodic feature vector can be derived from the calculated 3D palmprint data, so undistorted 3D biometrics is obtained. Using the obtained 3D palmprint data, feature matching test have been carried out by Gabor filter, competition rules and the mean curvature. Experimental results on capturing 3D palmprint show that the proposed acquisition method can fast get 3D shape information of palmprint. Some initial experiments on recognition show the proposed method is efficient by using 3D palmprint data.

  16. Using VIS/NIR and IR spectral cameras for detecting and separating crime scene details

    NASA Astrophysics Data System (ADS)

    Kuula, Jaana; Pölönen, Ilkka; Puupponen, Hannu-Heikki; Selander, Tuomas; Reinikainen, Tapani; Kalenius, Tapani; Saari, Heikki

    2012-06-01

    Detecting invisible details and separating mixed evidence is critical for forensic inspection. If this can be done reliably and fast at the crime scene, irrelevant objects do not require further examination at the laboratory. This will speed up the inspection process and release resources for other critical tasks. This article reports on tests which have been carried out at the University of Jyväskylä in Finland together with the Central Finland Police Department and the National Bureau of Investigation for detecting and separating forensic details with hyperspectral technology. In the tests evidence was sought after at an assumed violent burglary scene with the use of VTT's 500-900 nm wavelength VNIR camera, Specim's 400- 1000 nm VNIR camera, and Specim's 1000-2500 nm SWIR camera. The tested details were dried blood on a ceramic plate, a stain of four types of mixed and absorbed blood, and blood which had been washed off a table. Other examined details included untreated latent fingerprints, gunshot residue, primer residue, and layered paint on small pieces of wood. All cameras could detect visible details and separate mixed paint. The SWIR camera could also separate four types of human and animal blood which were mixed in the same stain and absorbed into a fabric. None of the cameras could however detect primer residue, untreated latent fingerprints, or blood that had been washed off. The results are encouraging and indicate the need for further studies. The results also emphasize the importance of creating optimal imaging conditions into the crime scene for each kind of subjects and backgrounds.

  17. Meteor velocity distribution from CILBO double station video camera data

    NASA Astrophysics Data System (ADS)

    Drolshagen, Esther; Ott, Theresa; Koschny, Detlef; Drolshagen, Gerhard; Poppe, Bjoern

    2014-02-01

    This paper is based on data from the double-station meteor camera setup on the Canary Islands - CILBO. The data has been collected from July 2011 until August 2014. The CILBO meteor data of one year (1 June 2013 - 31 May 2014) were used to analyze the velocity distribution of sporadic meteors and to compare the distribution to a reference distribution for near-Earth space. The velocity distribution for 1 AU outside the influence of Earth derived from the Harvard Radio Meteor Project (HRMP) was used as a reference. This HRMP distribution was converted to an altitude of 100 km by considering the gravitational attraction of Earth. The new, theoretical velocity distribution for a fixed meteoroid mass ranges from 11 - 71 𝑘𝑚/𝑠 and peaks at 12.5 𝑘𝑚/𝑠. This represents the predicted velocity distribution. The velocity distribution of the meteors detected simultaneously by both cameras of the CILBO system was examined. The meteors are sorted by their stream association and especially the velocity distribution of the sporadics is studied closely. The derived sporadic velocity distribution has a maximum at 64 𝑘𝑚/𝑠. This drastic difference to the theoretical curve confirms that fast meteors are usually greatly over-represented in optical and radar measurements of meteors. The majority of the fast sporadics are apparently caused by the Apex contribution in the early morning hours. This paper presents first results of the ongoing analysis of the meteor velocity distribution.

  18. Control Design and Digital Implementation of a Fast 2-Degree-of-Freedom Translational Optical Image Stabilizer for Image Sensors in Mobile Camera Phones

    PubMed Central

    Qiu, Kang-Fu

    2017-01-01

    This study presents design, digital implementation and performance validation of a lead-lag controller for a 2-degree-of-freedom (DOF) translational optical image stabilizer (OIS) installed with a digital image sensor in mobile camera phones. Nowadays, OIS is an important feature of modern commercial mobile camera phones, which aims to mechanically reduce the image blur caused by hand shaking while shooting photos. The OIS developed in this study is able to move the imaging lens by actuating its voice coil motors (VCMs) at the required speed to the position that significantly compensates for imaging blurs by hand shaking. The compensation proposed is made possible by first establishing the exact, nonlinear equations of motion (EOMs) for the OIS, which is followed by designing a simple lead-lag controller based on established nonlinear EOMs for simple digital computation via a field-programmable gate array (FPGA) board in order to achieve fast response. Finally, experimental validation is conducted to show the favorable performance of the designed OIS; i.e., it is able to stabilize the lens holder to the desired position within 0.02 s, which is much less than previously reported times of around 0.1 s. Also, the resulting residual vibration is less than 2.2–2.5 μm, which is commensurate to the very small pixel size found in most of commercial image sensors; thus, significantly minimizing image blur caused by hand shaking. PMID:29027950

  19. Control Design and Digital Implementation of a Fast 2-Degree-of-Freedom Translational Optical Image Stabilizer for Image Sensors in Mobile Camera Phones.

    PubMed

    Wang, Jeremy H-S; Qiu, Kang-Fu; Chao, Paul C-P

    2017-10-13

    This study presents design, digital implementation and performance validation of a lead-lag controller for a 2-degree-of-freedom (DOF) translational optical image stabilizer (OIS) installed with a digital image sensor in mobile camera phones. Nowadays, OIS is an important feature of modern commercial mobile camera phones, which aims to mechanically reduce the image blur caused by hand shaking while shooting photos. The OIS developed in this study is able to move the imaging lens by actuating its voice coil motors (VCMs) at the required speed to the position that significantly compensates for imaging blurs by hand shaking. The compensation proposed is made possible by first establishing the exact, nonlinear equations of motion (EOMs) for the OIS, which is followed by designing a simple lead-lag controller based on established nonlinear EOMs for simple digital computation via a field-programmable gate array (FPGA) board in order to achieve fast response. Finally, experimental validation is conducted to show the favorable performance of the designed OIS; i.e., it is able to stabilize the lens holder to the desired position within 0.02 s, which is much less than previously reported times of around 0.1 s. Also, the resulting residual vibration is less than 2.2-2.5 μm, which is commensurate to the very small pixel size found in most of commercial image sensors; thus, significantly minimizing image blur caused by hand shaking.

  20. A fast non-contact imaging photoplethysmography method using a tissue-like model

    NASA Astrophysics Data System (ADS)

    McDuff, Daniel J.; Blackford, Ethan B.; Estepp, Justin R.; Nishidate, Izumi

    2018-02-01

    Imaging photoplethysmography (iPPG) allows non-contact, concomitant measurement and visualization of peripheral blood flow using just an RGB camera. Most iPPG methods require a window of temporal data and complex computation, this makes real-time measurement and spatial visualization impossible. We present a fast,"window-less", non-contact imaging photoplethysmography method, based on a tissue-like model of the skin, that allows accurate measurement of heart rate and heart rate variability parameters. The error in heart rate estimates is equivalent to state-of-the-art techniques and computation is much faster.

  1. 1 μs broadband frequency sweeping reflectometry for plasma density and fluctuation profile measurements

    NASA Astrophysics Data System (ADS)

    Clairet, F.; Bottereau, C.; Medvedeva, A.; Molina, D.; Conway, G. D.; Silva, A.; Stroth, U.; ASDEX Upgrade Team; Tore Supra Team; Eurofusion Mst1 Team

    2017-11-01

    Frequency swept reflectometry has reached the symbolic value of 1 μs sweeping time; this performance has been made possible, thanks to an improved control of the ramp voltage driving the frequency source. In parallel, the memory depth of the acquisition system has been upgraded and can provide up to 200 000 signals during a plasma discharge. Additional improvements regarding the trigger delay determination of the acquisition and the voltage ramp linearity required by this ultra-fast technique have been set. While this diagnostic is traditionally dedicated to the plasma electron density profile measurement, such a fast sweeping rate can provide the study of fast plasma events and turbulence with unprecedented time and radial resolution from the edge to the core. Experimental results obtained on ASDEX Upgrade plasmas are presented to demonstrate the performances of the diagnostic.

  2. The software-defined fast post-processing for GEM soft x-ray diagnostics in the Tungsten Environment in Steady-state Tokamak thermal fusion reactor

    NASA Astrophysics Data System (ADS)

    Krawczyk, Rafał Dominik; Czarski, Tomasz; Linczuk, Paweł; Wojeński, Andrzej; Kolasiński, Piotr; GÄ ska, Michał; Chernyshova, Maryna; Mazon, Didier; Jardin, Axel; Malard, Philippe; Poźniak, Krzysztof; Kasprowicz, Grzegorz; Zabołotny, Wojciech; Kowalska-Strzeciwilk, Ewa; Malinowski, Karol

    2018-06-01

    This article presents a novel software-defined server-based solutions that were introduced in the fast, real-time computation systems for soft X-ray diagnostics for the WEST (Tungsten Environment in Steady-state Tokamak) reactor in Cadarache, France. The objective of the research was to provide a fast processing of data at high throughput and with low latencies for investigating the interplay between the particle transport and magnetohydrodynamic activity. The long-term objective is to implement in the future a fast feedback signal in the reactor control mechanisms to sustain the fusion reaction. The implemented electronic measurement device is anticipated to be deployed in the WEST. A standalone software-defined computation engine was designed to handle data collected at high rates in the server back-end of the system. Signals are obtained from the front-end field-programmable gate array mezzanine cards that acquire and perform a selection from the gas electron multiplier detector. A fast, authorial library for plasma diagnostics was written in C++. It originated from reference offline MATLAB implementations. They were redesigned for runtime analysis during the experiment in the novel online modes of operation. The implementation allowed the benchmarking, evaluation, and optimization of plasma processing algorithms with the possibility to check the consistency with reference computations written in MATLAB. The back-end software and hardware architecture are presented with data evaluation mechanisms. The online modes of operation for the WEST are discussed. The results concerning the performance of the processing and the introduced functionality are presented.

  3. Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D.

    PubMed

    Chen, J; Ding, W X; Brower, D L; Finkenthal, D; Muscatello, C; Taussig, D; Boivin, R

    2016-11-01

    Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

  4. The Role of Computed Tomography in Blunt Abdominal Trauma.

    PubMed

    Karki, O B

    2015-01-01

    Blunt injury trauma is regularly encountered in the emergency department. Diagnostic tools that help in optimum management of blunt abdominal trauma include; Focussed Assessment Sonography for Trauma scan, Diagnostic peritoneal lavage and Computed Tomography scan. The aim of this study is to determine the validity of CT scan as an accurate diagnostic tool and its role in management of patients with blunt abdominal trauma. A prospective analysis of 80 patients of blunt abdomen trauma who were admitted in Manipal Teaching Hospital, Pokhara, Nepal within a span of 15 months was done. Demographic data, mechanism of trauma, management and outcomes were studied. Organ injuries were graded using the Organ Injury Scale guidelines. Most of the patients in our study were in the age group of 21-40 years with an M: F ratio of 2.3:1. Road traffic accident (47.5%) was the most common mechanism of injury. Spleen (27.5%) was the commonest organ injured. CT scan was superior to FAST scan and had sensitivity of 97.3% specificity 75% positive predictive value 98.6%. FAST scan had sensitivity of 78.9%, specificity 50%, positive predictive value 96% with p- value of 0.0034. 81% of patients were conservatively managed. In conjunction with close clinical monitoring, CT scan is reliable in the evaluation and management of blunt abdominal trauma patients. Our study also shows CT as a superior diagnostic modality compared to FAST scan.

  5. Nike Facility Diagnostics and Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Chan, Yung; Aglitskiy, Yefim; Karasik, Max; Kehne, David; Obenschain, Steve; Oh, Jaechul; Serlin, Victor; Weaver, Jim

    2013-10-01

    The Nike laser-target facility is a 56-beam krypton fluoride system that can deliver 2 to 3 kJ of laser energy at 248 nm onto targets inside a two meter diameter vacuum chamber. Nike is used to study physics and technology issues related to laser direct-drive ICF fusion, including hydrodynamic and laser-plasma instabilities, material behavior at extreme pressures, and optical and x-ray diagnostics for laser-heated targets. A suite of laser and target diagnostics are fielded on the Nike facility, including high-speed, high-resolution x-ray and visible imaging cameras, spectrometers and photo-detectors. A centrally-controlled, distributed computerized data acquisition system provides robust data management and near real-time analysis feedback capability during target shots. Work supported by DOE/NNSA.

  6. Estimation of Salivary Glucose and Glycogen Content in Exfoliated Buccal Mucosal Cells of Patients with Type II Diabetes Mellitus

    PubMed Central

    Gopinathan, Deepa Moothedathu; Sukumaran, Sunil

    2015-01-01

    Background Diabetes mellitus is a common metabolic disorder which shows an increasing incidence worldwide. Constant monitoring of blood glucose in diabetic patient is required which involves painful invasive techniques. Saliva is gaining acceptance as diagnostic tool for various systemic diseases which can be collected noninvasively and by individuals with limited training. Aim The aim of the present study was to analyse the possibility of using salivary glucose and glycogen content of buccal mucosal cells as a diagnostic marker in Type II Diabetes mellitus patients which can be considered as adjuvant diagnostic tool to the gold standards. Materials and Methods Sample consists of 30 study and 30 control groups. Saliva was collected by passive drool method.Intravenous blood samples were collected for glucose estimation. Exfoliated buccal mucosal cells were collected from apparently normal buccal mucosa, smeared on dry glass slide and stained with PAS. Blood and salivary glucose are estimated by Glucose Oxidase endpoint method. For Glycogen estimation, number of PAS positive cells in fifty unfolded cells was analysed. Results The results of the present study revealed a significant increase in the salivary glucose level and the number of PAS positive buccal mucosal cells in the diabetics than in the controls. The correlation between the fasting serum glucose and fasting salivary glucose and also that between fasting serum glucose and PAS positive cells was statistically significant. But the correlation between the staining intensity and fasting serum glucose was statistically insignificant. Conclusion With the results of the present study it is revealed that salivary glucose and PAS positive cells are increased in diabetics which can be considered as adjuvant diagnostic tool for Diabetes mellitus. PMID:26155572

  7. Thermographic diagnostics to discriminate skin lesions: a clinical study

    NASA Astrophysics Data System (ADS)

    Stringasci, Mirian Denise; Moriyama, Lilian Tan; Salvio, Ana Gabriela; Bagnato, Vanderlei Salvador; Kurachi, Cristina

    2015-06-01

    Cancer is responsible for about 13% of all causes of death in the world. Over 7 million people die annually of this disease. In most cases, the survival rates are greater when diagnosed in early stages. It is known that tumor lesions present a different temperature compared with the normal tissues. Some studies have been performed in an attempt to establish new diagnosis methods, targeting this temperature difference. In this study, we aim to investigate the use of a handheld thermographic camera to discriminate skin lesions. The patients presenting Basal Cell Carcinoma, Squamous Cell Carcinoma, Actinic Keratosis, Pigmented Seborrheic Keratosis, Melanoma or Intradermal Nevus lesions have been investigated at the Skin Departament of Amaral Carvalho Hospital. Patients are selected by a dermatologist, and the lesion images are recorded using an infrared camera. The images are evaluated taken into account the temperature level, and differences into lesion areas, borders, and between altered and normal skin. The present results show that thermography may be an important tool for aiding in the clinical diagnostics of superficial skin lesions.

  8. Development of Surface Eroding Thermocouples in DIII-D

    NASA Astrophysics Data System (ADS)

    Ren, Jun; Donovan, David; Watkins, Jon; Wang, Huiqian; Rudakov, Dmitry; Murphy, Christopher; Unterberg, Ezekial; Thomas, Dan; Boivin, Rejean

    2017-10-01

    The Surface Eroding Thermocouple (SETC) is a specialized diagnostic for characterizing the surface temperature evolution with a high temporal resolution ( 1ms) which is especially useful in areas unobservable by line-of-sight diagnostics (e.g. IR cameras). Recently, SETCs were tested in DiMES and successfully acquired temperature signals during strike point sweeps on the lower divertor shelf. We observed that the SETCs have a sub-10 ms time response and is sufficient to resolve ELM heat pulses. Preliminary analysis shows heat fluxes measured by SETCs and IR camera agree within 20%. Comparison of SETCs, calorimeters and Langmuir probe also show good agreement. We plan to implement an array of SETCs embedded in the tiles forming the new DIII-D small angle slot (SAS) divertor. Strategies to improve the SNR of these SETCs through testing in DiMES before the final installation will be discussed. This work was supported by the US Department of Energy under DE-SC0016318 (UTK), DE-AC05-00OR22725 (ORNL), DE-FG02-07ER54917 (UCSD), DE-FC02-04ER54698 (GA), DE-AC04-94AL85000 (SNL).

  9. Demonstration of Imaging Flow Diagnostics Using Rayleigh Scattering in Langley 0.3-Meter Transonic Cryogenic Tunnel

    NASA Technical Reports Server (NTRS)

    Shirinzadeh, B.; Herring, G. C.; Barros, Toya

    1999-01-01

    The feasibility of using the Rayleigh scattering technique for molecular density imaging of the free-stream flow field in the Langley 0.3-Meter Transonic Cryogenic Tunnel has been experimentally demonstrated. The Rayleigh scattering was viewed with a near-backward geometry with a frequency-doubled output from a diode-pumped CW Nd:YAG laser and an intensified charge-coupled device camera. Measurements performed in the range of free-stream densities from 3 x 10(exp 25) to 24 x 10(exp 25) molecules/cu m indicate that the observed relative Rayleigh signal levels are approximately linear with flow field density. The absolute signal levels agree (within approx. 30 percent) with the expected signal levels computed based on the well-known quantities of flow field density, Rayleigh scattering cross section for N2, solid angle of collection, transmission of the optics, and the independently calibrated camera sensitivity. These results show that the flow field in this facility is primarily molecular (i.e., not contaminated by clusters) and that Rayleigh scattering is a viable technique for quantitative nonintrusive diagnostics in this facility.

  10. Imaging strategies for the study of gas turbine spark ignition

    NASA Astrophysics Data System (ADS)

    Gord, James R.; Tyler, Charles; Grinstead, Keith D., Jr.; Fiechtner, Gregory J.; Cochran, Michael J.; Frus, John R.

    1999-10-01

    Spark-ignition systems play a critical role in the performance of essentially all gas turbine engines. These devices are responsible for initiating the combustion process that sustains engine operation. Demanding applications such as cold start and high-altitude relight require continued enhancement of ignition systems. To characterize advanced ignition systems, we have developed a number of laser-based diagnostic techniques configured for ultrafast imaging of spark parameters including emission, density, temperature, and species concentration. These diagnostics have been designed to exploit an ultrafast- framing charge-coupled-device (CCD) camera and high- repetition-rate laser sources including mode-locked Ti:sapphire oscillators and regenerative amplifiers. Spontaneous-emission and laser-shlieren measurements have been accomplished with this instrumentation and the result applied to the study of a novel Unison Industries spark igniter that shows great promise for improved cold-start and high-altitude-relight capability as compared to that of igniters currently in use throughout military and commercial fleets. Phase-locked and ultrafast real-time imaging strategies are explored, and details of the imaging instrumentation, particularly the CCD camera and laser sources, are discussed.

  11. Novel energy resolving x-ray pinhole camera on Alcator C-Mod.

    PubMed

    Pablant, N A; Delgado-Aparicio, L; Bitter, M; Brandstetter, S; Eikenberry, E; Ellis, R; Hill, K W; Hofer, P; Schneebeli, M

    2012-10-01

    A new energy resolving x-ray pinhole camera has been recently installed on Alcator C-Mod. This diagnostic is capable of 1D or 2D imaging with a spatial resolution of ≈1 cm, an energy resolution of ≈1 keV in the range of 3.5-15 keV and a maximum time resolution of 5 ms. A novel use of a Pilatus 2 hybrid-pixel x-ray detector [P. Kraft et al., J. Synchrotron Rad. 16, 368 (2009)] is employed in which the lower energy threshold of individual pixels is adjusted, allowing regions of a single detector to be sensitive to different x-ray energy ranges. Development of this new detector calibration technique was done as a collaboration between PPPL and Dectris Ltd. The calibration procedure is described, and the energy resolution of the detector is characterized. Initial data from this installation on Alcator C-Mod is presented. This diagnostic provides line-integrated measurements of impurity emission which can be used to determine impurity concentrations as well as the electron energy distribution.

  12. Modulated CMOS camera for fluorescence lifetime microscopy.

    PubMed

    Chen, Hongtao; Holst, Gerhard; Gratton, Enrico

    2015-12-01

    Widefield frequency-domain fluorescence lifetime imaging microscopy (FD-FLIM) is a fast and accurate method to measure the fluorescence lifetime of entire images. However, the complexity and high costs involved in construction of such a system limit the extensive use of this technique. PCO AG recently released the first luminescence lifetime imaging camera based on a high frequency modulated CMOS image sensor, QMFLIM2. Here we tested and provide operational procedures to calibrate the camera and to improve the accuracy using corrections necessary for image analysis. With its flexible input/output options, we are able to use a modulated laser diode or a 20 MHz pulsed white supercontinuum laser as the light source. The output of the camera consists of a stack of modulated images that can be analyzed by the SimFCS software using the phasor approach. The nonuniform system response across the image sensor must be calibrated at the pixel level. This pixel calibration is crucial and needed for every camera settings, e.g. modulation frequency and exposure time. A significant dependency of the modulation signal on the intensity was also observed and hence an additional calibration is needed for each pixel depending on the pixel intensity level. These corrections are important not only for the fundamental frequency, but also for the higher harmonics when using the pulsed supercontinuum laser. With these post data acquisition corrections, the PCO CMOS-FLIM camera can be used for various biomedical applications requiring a large frame and high speed acquisition. © 2015 Wiley Periodicals, Inc.

  13. Progress On The Thomson Scattering Diagnostic For The Helicon Plasma Experiment (HPX)

    NASA Astrophysics Data System (ADS)

    Green, A.; Emami, T.; Davies, R.; Frank, J.; Hopson, J.; Karama, J.; James, R. W.; Hopson, J.; Paolino, R. N.; Sandri, E.; Turk, J.; Wicke, M.; Cgapl Team

    2017-10-01

    A high-performance spectrometer utilizing volume-phase-holographic (VPH) grating and a charge coupled device (CCD) camera with a range of 380-1090 nm and resolution of 1024x1024 has been assembled on HPX at the Coast Guard Academy Plasma Laboratory (CGAPL). This spectrometer will collect doppler shifted photons, emitted from the plasma by the first harmonic (1064 nm) of a 2.5 J Nd:YAG laser. Direct measurements of the plasma's temperature and density will be determined using HPX's Thomson Scattering (TS) single spatial point diagnostic system. A zero order half wave plate rotates the polarization of the second harmonic TS laser beam when operating at a wavelength of 532 nm. A linear actuated periscope has been constructed to remotely redirect the beam so that 532 and 1064 nm wavelengths can both be used. TS has the capability of determining plasma properties on short time scales and will be used to create a robust picture of the internal plasma parameters. Operating at both 532 and 1064 nm results in a self-consistent measurement and better use our existing spectrometer and soon to be constructed polychrometer. A prototype spectrometer has been constructed to explore the Andor CCD camera's resolution and sensitivity. The current status of the diagnostic development, spectrometer, and collection optics system will be reported. Supported by U.S. DEPS Grant [HEL-JTO] PRWJFY17.

  14. Multiple-target tracking implementation in the ebCMOS camera system: the LUSIPHER prototype

    NASA Astrophysics Data System (ADS)

    Doan, Quang Tuyen; Barbier, Remi; Dominjon, Agnes; Cajgfinger, Thomas; Guerin, Cyrille

    2012-06-01

    The domain of the low light imaging systems progresses very fast, thanks to detection and electronic multiplication technology evolution, such as the emCCD (electron multiplying CCD) or the ebCMOS (electron bombarded CMOS). We present an ebCMOS camera system that is able to track every 2 ms more than 2000 targets with a mean number of photons per target lower than two. The point light sources (targets) are spots generated by a microlens array (Shack-Hartmann) used in adaptive optics. The Multiple-Target-Tracking designed and implemented on a rugged workstation is described. The results and the performances of the system on the identification and tracking are presented and discussed.

  15. Light field reconstruction robust to signal dependent noise

    NASA Astrophysics Data System (ADS)

    Ren, Kun; Bian, Liheng; Suo, Jinli; Dai, Qionghai

    2014-11-01

    Capturing four dimensional light field data sequentially using a coded aperture camera is an effective approach but suffers from low signal noise ratio. Although multiplexing can help raise the acquisition quality, noise is still a big issue especially for fast acquisition. To address this problem, this paper proposes a noise robust light field reconstruction method. Firstly, scene dependent noise model is studied and incorporated into the light field reconstruction framework. Then, we derive an optimization algorithm for the final reconstruction. We build a prototype by hacking an off-the-shelf camera for data capturing and prove the concept. The effectiveness of this method is validated with experiments on the real captured data.

  16. Real-time image mosaicing for medical applications.

    PubMed

    Loewke, Kevin E; Camarillo, David B; Jobst, Christopher A; Salisbury, J Kenneth

    2007-01-01

    In this paper we describe the development of a robotically-assisted image mosaicing system for medical applications. The processing occurs in real-time due to a fast initial image alignment provided by robotic position sensing. Near-field imaging, defined by relatively large camera motion, requires translations as well as pan and tilt orientations to be measured. To capture these measurements we use 5-d.o.f. sensing along with a hand-eye calibration to account for sensor offset. This sensor-based approach speeds up the mosaicing, eliminates cumulative errors, and readily handles arbitrary camera motions. Our results have produced visually satisfactory mosaics on a dental model but can be extended to other medical images.

  17. Characterization of TimepixCam, a fast imager for the time-stamping of optical photons

    NASA Astrophysics Data System (ADS)

    Nomerotski, Andrei; Chakaberia, I.; Fisher-Levine, M.; Janoska, Z.; Takacs, P.; Tsang, T.

    2017-01-01

    We describe the characterization of TimepixCam, a novel camera used to time-stamp optical photons. The camera employs a specialized silicon sensor with a thin entrance window, read out by a Timepix ASIC. TimepixCam is able to record and time-stamp light flashes exceeding 1,000 photons with 15 ns time resolution. Specially produced photodiodes were used to evaluate the quantum efficiency, which was determined to be higher than 90% in the wavelength range of 430-900 nm. The quantum efficiency, sensitivity and ion detection efficiency were compared for a variety of sensors with different surface treatments. Sensors with the thinnest window, 50 nm, had the best performance.

  18. PIA01492

    NASA Image and Video Library

    1998-10-30

    This picture of Neptune was produced from the last whole planet images taken through the green and orange filters on NASA's Voyager 2 narrow angle camera. The images were taken at a range of 4.4 million miles from the planet, 4 days and 20 hours before closest approach. The picture shows the Great Dark Spot and its companion bright smudge; on the west limb the fast moving bright feature called Scooter and the little dark spot are visible. These clouds were seen to persist for as long as Voyager's cameras could resolve them. North of these, a bright cloud band similar to the south polar streak may be seen. http://photojournal.jpl.nasa.gov/catalog/PIA01492

  19. Base Rates: Both Neglected and Intuitive

    ERIC Educational Resources Information Center

    Pennycook, Gordon; Trippas, Dries; Handley, Simon J.; Thompson, Valerie A.

    2014-01-01

    Base-rate neglect refers to the tendency for people to underweight base-rate probabilities in favor of diagnostic information. It is commonly held that base-rate neglect occurs because effortful (Type 2) reasoning is required to process base-rate information, whereas diagnostic information is accessible to fast, intuitive (Type 1) processing…

  20. Time-domain laser-induced fluorescence spectroscopy apparatus for clinical diagnostics

    NASA Astrophysics Data System (ADS)

    Fang, Qiyin; Papaioannou, Thanassis; Jo, Javier A.; Vaitha, Russel; Shastry, Kumar; Marcu, Laura

    2004-01-01

    We report the design and development of a compact optical fiber-based apparatus for in situ time-resolved laser-induced fluorescence spectroscopy (tr-LIFS) of biological systems. The apparatus is modular, optically robust, and compatible with the clinical environment. It incorporates a dual output imaging spectrograph, a gated multichannel plate photomultiplier (MCP-PMT), an intensified charge-coupled-device (ICCD) camera, and a fast digitizer. It can accommodate various types of light sources and optical fiber probes for selective excitation and remote light delivery/collection as required by different applications. The apparatus allows direct recording of the entire fluorescence decay with high sensitivity (nM range fluorescein dye concentration with signal-to-noise ratio of 46) and with four decades dynamic range. It is capable of resolving a broad range of fluorescence lifetimes from hundreds of picoseconds (as low as 300 ps) using the MCP-PMT coupled to the digitizer to milliseconds using the ICCD. The data acquisition and analysis process is fully automated, enabling fast recording of fluorescence intensity decay across the entire emission spectrum (0.8 s per wavelength or ˜40 s for a 200 nm wavelength range at 5 nm increments). The spectral and temporal responses of the apparatus were calibrated and its performance was validated using fluorescence lifetime standard dyes (Rhodamin B, 9-cyanoanthracene, and rose Bengal) and tissue endogenous fluorophores (elastin, collagen, nicotinamide adenine dinucleotide, and flavin adenine dinucleotide). Fluorescence decay lifetimes and emission spectra of all tested compounds measured with the current tr-LIFS apparatus were found in good agreement with the values reported in the literature. The design and performance of tr-LIFS apparatus have enabled in vivo studies of atherosclerotic plaques and brain tumors.

  1. High-speed spectral domain optical coherence tomography using non-uniform fast Fourier transform

    PubMed Central

    Chan, Kenny K. H.; Tang, Shuo

    2010-01-01

    The useful imaging range in spectral domain optical coherence tomography (SD-OCT) is often limited by the depth dependent sensitivity fall-off. Processing SD-OCT data with the non-uniform fast Fourier transform (NFFT) can improve the sensitivity fall-off at maximum depth by greater than 5dB concurrently with a 30 fold decrease in processing time compared to the fast Fourier transform with cubic spline interpolation method. NFFT can also improve local signal to noise ratio (SNR) and reduce image artifacts introduced in post-processing. Combined with parallel processing, NFFT is shown to have the ability to process up to 90k A-lines per second. High-speed SD-OCT imaging is demonstrated at camera-limited 100 frames per second on an ex-vivo squid eye. PMID:21258551

  2. Fundamentals of Arthroscopic Surgery Training Program Improves Knee Arthroscopy Simulator Performance in Arthroscopic Trainees.

    PubMed

    Cychosz, Chris C; Tofte, Josef N; Johnson, Alyssa; Gao, Yubo; Phisitkul, Phinit

    2018-05-01

    To determine the effectiveness of a nonanatomic simulator in developing basic arthroscopy motor skills transferable to an anatomic model. Forty-three arthroscopy novice individuals currently enrolled in medical school were recruited to perform a diagnostic knee arthroscopy using a high-fidelity virtual reality arthroscopic simulator providing haptic feedback after viewing a video of an expert performing an identical procedure. Students were then randomized into an experimental or control group. The experimental group then completed a series of self-guided training modules using the fundamentals of arthroscopy simulator training nonanatomic modules including camera centering, tracking, periscoping, palpation, and collecting stars in a three-dimensional space. Both groups completed another diagnostic knee arthroscopy between 1 and 2 weeks later. Camera path length, time, tibia and femur cartilage damage, as well as a composite score were recorded by the simulator on each attempt. The experimental group (n = 22) showed superior performance in composite score (30.09 vs 24, P = .046) and camera path length (71.51 cm vs 109.07 cm, P = .0274) at the time of the second diagnostic knee arthroscope compared with the control group (n = 21). The experimental group also showed significantly greater improvement in composite score between the first and second arthroscopes compared with the control group (14.27 vs 4.95, P < .01). Femoral and tibial cartilage damage were not significantly improved between arthroscopy attempts (-0.86% vs -1.45%, P = .40) and (-1.10 vs -1.27%, P = .83), respectively. The virtual reality-based fundamentals of arthroscopy simulator training nonanatomic simulator is beneficial in developing basic motor skills in arthroscopy novice individuals resulting in significantly greater composite performance in an anatomic knee model. Based on the results of this study, it appears that there may be benefit from nonanatomic simulators in general as part of an arthroscopy training program. Level II, randomized trial. Published by Elsevier Inc.

  3. Variation in 'fast-track' referrals for suspected cancer by patient characteristic and cancer diagnosis: evidence from 670 000 patients with cancers of 35 different sites.

    PubMed

    Zhou, Y; Mendonca, S C; Abel, G A; Hamilton, W; Walter, F M; Johnson, S; Shelton, J; Elliss-Brookes, L; McPhail, S; Lyratzopoulos, G

    2018-01-01

    In England, 'fast-track' (also known as 'two-week wait') general practitioner referrals for suspected cancer in symptomatic patients are used to shorten diagnostic intervals and are supported by clinical guidelines. However, the use of the fast-track pathway may vary for different patient groups. We examined data from 669 220 patients with 35 cancers diagnosed in 2006-2010 following either fast-track or 'routine' primary-to-secondary care referrals using 'Routes to Diagnosis' data. We estimated the proportion of fast-track referrals by sociodemographic characteristic and cancer site and used logistic regression to estimate respective crude and adjusted odds ratios. We additionally explored whether sociodemographic associations varied by cancer. There were large variations in the odds of fast-track referral by cancer (P<0.001). Patients with testicular and breast cancer were most likely to have been diagnosed after a fast-track referral (adjusted odds ratios 2.73 and 2.35, respectively, using rectal cancer as reference); whereas patients with brain cancer and leukaemias least likely (adjusted odds ratios 0.05 and 0.09, respectively, for brain cancer and acute myeloid leukaemia). There were sex, age and deprivation differences in the odds of fast-track referral (P<0.013) that varied in their size and direction for patients with different cancers (P<0.001). For example, fast-track referrals were least likely in younger women with endometrial cancer and in older men with testicular cancer. Fast-track referrals are less likely for cancers characterised by nonspecific presenting symptoms and patients belonging to low cancer incidence demographic groups. Interventions beyond clinical guidelines for 'alarm' symptoms are needed to improve diagnostic timeliness.

  4. Variation in ‘fast-track’ referrals for suspected cancer by patient characteristic and cancer diagnosis: evidence from 670 000 patients with cancers of 35 different sites

    PubMed Central

    Zhou, Y; Mendonca, S C; Abel, G A; Hamilton, W; Walter, F M; Johnson, S; Shelton, J; Elliss-Brookes, L; McPhail, S; Lyratzopoulos, G

    2018-01-01

    Background: In England, ‘fast-track’ (also known as ‘two-week wait’) general practitioner referrals for suspected cancer in symptomatic patients are used to shorten diagnostic intervals and are supported by clinical guidelines. However, the use of the fast-track pathway may vary for different patient groups. Methods: We examined data from 669 220 patients with 35 cancers diagnosed in 2006–2010 following either fast-track or ‘routine’ primary-to-secondary care referrals using ‘Routes to Diagnosis’ data. We estimated the proportion of fast-track referrals by sociodemographic characteristic and cancer site and used logistic regression to estimate respective crude and adjusted odds ratios. We additionally explored whether sociodemographic associations varied by cancer. Results: There were large variations in the odds of fast-track referral by cancer (P<0.001). Patients with testicular and breast cancer were most likely to have been diagnosed after a fast-track referral (adjusted odds ratios 2.73 and 2.35, respectively, using rectal cancer as reference); whereas patients with brain cancer and leukaemias least likely (adjusted odds ratios 0.05 and 0.09, respectively, for brain cancer and acute myeloid leukaemia). There were sex, age and deprivation differences in the odds of fast-track referral (P<0.013) that varied in their size and direction for patients with different cancers (P<0.001). For example, fast-track referrals were least likely in younger women with endometrial cancer and in older men with testicular cancer. Conclusions: Fast-track referrals are less likely for cancers characterised by nonspecific presenting symptoms and patients belonging to low cancer incidence demographic groups. Interventions beyond clinical guidelines for ‘alarm’ symptoms are needed to improve diagnostic timeliness. PMID:29182609

  5. Further detection of the optical low frequency QPO in the black hole transient MAXI J1820+070

    NASA Astrophysics Data System (ADS)

    Yu, Wenfei; Lin, Jie; Mao, Dongming; Zhang, Jujia; Yan, Zhen; Bai, Jinming

    2018-05-01

    We report on the optical photometric observation of MAXI J1820+070 with the 2.4m telescope at Lijiang Gaomeigu Station of Yunnan observatories with our Fast Optical Camera (FOC) on April 22, 2018, following the detection of low frequency QPO in the optical band (ATEL #11510).

  6. The research of binocular vision ranging system based on LabVIEW

    NASA Astrophysics Data System (ADS)

    Li, Shikuan; Yang, Xu

    2017-10-01

    Based on the study of the principle of binocular parallax ranging, a binocular vision ranging system is designed and built. The stereo matching algorithm is realized by LabVIEW software. The camera calibration and distance measurement are completed. The error analysis shows that the system fast, effective, can be used in the corresponding industrial occasions.

  7. Two-dimensional Imaging Velocity Interferometry: Technique and Data Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erskine, D J; Smith, R F; Bolme, C

    2011-03-23

    We describe the data analysis procedures for an emerging interferometric technique for measuring motion across a two-dimensional image at a moment in time, i.e. a snapshot 2d-VISAR. Velocity interferometers (VISAR) measuring target motion to high precision have been an important diagnostic in shockwave physics for many years Until recently, this diagnostic has been limited to measuring motion at points or lines across a target. We introduce an emerging interferometric technique for measuring motion across a two-dimensional image, which could be called a snapshot 2d-VISAR. If a sufficiently fast movie camera technology existed, it could be placed behind a traditional VISARmore » optical system and record a 2d image vs time. But since that technology is not yet available, we use a CCD detector to record a single 2d image, with the pulsed nature of the illumination providing the time resolution. Consequently, since we are using pulsed illumination having a coherence length shorter than the VISAR interferometer delay ({approx}0.1 ns), we must use the white light velocimetry configuration to produce fringes with significant visibility. In this scheme, two interferometers (illuminating, detecting) having nearly identical delays are used in series, with one before the target and one after. This produces fringes with at most 50% visibility, but otherwise has the same fringe shift per target motion of a traditional VISAR. The 2d-VISAR observes a new world of information about shock behavior not readily accessible by traditional point or 1d-VISARS, simultaneously providing both a velocity map and an 'ordinary' snapshot photograph of the target. The 2d-VISAR has been used to observe nonuniformities in NIF related targets (polycrystalline diamond, Be), and in Si and Al.« less

  8. History and structures of telecommunication in pathology, focusing on open access platforms.

    PubMed

    Kayser, Klaus; Borkenfeld, Stephan; Djenouni, Amina; Kayser, Gian

    2011-11-07

    Telecommunication has matured to a broadly applied tool in diagnostic pathology. Contemporary with the development of fast electronic communication lines (Integrated digital network services (ISDN), broad band connections, and fibre optics, as well as the digital imaging technology (digital camera), telecommunication in tissue--based diagnosis (telepathology) has matured. Open access (internet) and server--based communication have induced the development of specific medical information platforms, such as iPATH, UICC-TPCC (telepathology consultation centre of the Union International against Cancer), or the Armed Forces Institute of Pathology (AFIP) teleconsultation system. They have been closed, and are subject to be replaced by specific open access forums (Medical Electronic Expert Communication System (MECES) with embedded virtual slide (VS) technology). MECES uses php language, data base driven mySqL architecture, X/L-AMPP infrastructure, and browser friendly W3C conform standards. The server--based medical communication systems (AFIP, iPATH, UICC-TPCC) have been reported to be a useful and easy to handle tool for expert consultation. Correct sampling and evaluation of transmitted still images by experts reported revealed no or only minor differences to the original images and good practice of the involved experts. β tests with the new generation medical expert consultation systems (MECES) revealed superior results in terms of performance, still image viewing, and system handling, especially as this is closely related to the use of so--called social forums (facebook, youtube, etc.). In addition to the acknowledged advantages of the former established systems (assistance of pathologists working in developing countries, diagnosis confirmation, international information exchange, etc.), the new generation offers additional benefits such as acoustic information transfer, assistance in image screening, VS technology, and teaching in diagnostic sampling, judgement, and verification.

  9. In-situ monitoring by reflective high energy electron diffraction during pulsed laser deposition

    NASA Astrophysics Data System (ADS)

    Blank, Dave H. A.; Rijnders, Guus J. H. M.; Koster, Gertjan; Rogalla, Horst

    1999-01-01

    Pulsed laser deposition (PLD) has developed during the past decade from a fast but limited preparation tool towards a competitive thin film deposition technique. One of the advantages above other techniques is the possibility of growth at relative high background pressure. There is a large freedom in choosing which kind of gas. Moreover, in a number of applications, the gaseous species in the background pressure are part of the elements to be grown, e.g., oxygen in the case of high Tc superconductors. However, the advantage of relative high pressures leads to restrictions of using standard diagnostics and monitoring of the film growth, e.g., reflective high energy electron diffraction (RHEED). Here, a PLD chamber including an in-situ RHEED system is presented, which makes it possible to monitor and study the growth at standard PLD parameters. Using a two-stages differential pumped, magnetically shielded, extension tube mounted at the electron gun side and a special designed phosphor screen including CCD camera, real time monitoring by observation of RHEED oscillations could be established at pressures up to 50 Pa. In this paper the latest results on applying this technique on SrTiO 3 and YBa 2Cu 3O 7 will be presented. Additional to the usual diagnostics performed with RHEED, another phenomena can be observed. The pulsed way of deposition, characteristic for PLD, leads to relaxations in the intensity of the diffracted pattern due to the mobility of the deposited material. These relaxation times give extra information about relaxation, crystallization, and nucleation of the deposited material. The presented technique leads to a better understanding of the growth during pulsed laser deposition and, because of the possibility to monitor the growth, will make PLD competitive with other deposition techniques.

  10. Estimation of melanin content in iris of human eye: prognosis for glaucoma diagnostics

    NASA Astrophysics Data System (ADS)

    Bashkatov, Alexey N.; Koblova, Ekaterina V.; Genina, Elina A.; Kamenskikh, Tatyana G.; Dolotov, Leonid E.; Sinichkin, Yury P.; Tuchin, Valery V.

    2007-02-01

    Based on the experimental data obtained in vivo from digital analysis of color images of human irises, the mean melanin content in human eye irises has been estimated. For registration of the color images a digital camera Olympus C-5060 has been used. The images have been obtained from irises of healthy volunteers as well as from irises of patients with open-angle glaucoma. The computer program has been developed for digital analysis of the images. The result has been useful for development of novel and optimization of already existing methods of non-invasive glaucoma diagnostics.

  11. Diffuse optical microscopy for quantification of depth-dependent epithelial backscattering in the cervix

    NASA Astrophysics Data System (ADS)

    Bodenschatz, Nico; Lam, Sylvia; Carraro, Anita; Korbelik, Jagoda; Miller, Dianne M.; McAlpine, Jessica N.; Lee, Marette; Kienle, Alwin; MacAulay, Calum

    2016-06-01

    A fiber optic imaging approach is presented using structured illumination for quantification of almost pure epithelial backscattering. We employ multiple spatially modulated projection patterns and camera-based reflectance capture to image depth-dependent epithelial scattering. The potential diagnostic value of our approach is investigated on cervical ex vivo tissue specimens. Our study indicates a strong backscattering increase in the upper part of the cervical epithelium caused by dysplastic microstructural changes. Quantization of relative depth-dependent backscattering is confirmed as a potentially useful diagnostic feature for detection of precancerous lesions in cervical squamous epithelium.

  12. Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM).

    PubMed

    Agostini, Denis; Marie, Pierre-Yves; Ben-Haim, Simona; Rouzet, François; Songy, Bernard; Giordano, Alessandro; Gimelli, Alessia; Hyafil, Fabien; Sciagrà, Roberto; Bucerius, Jan; Verberne, Hein J; Slart, Riemer H J A; Lindner, Oliver; Übleis, Christopher; Hacker, Marcus

    2016-12-01

    The trade-off between resolution and count sensitivity dominates the performance of standard gamma cameras and dictates the need for relatively high doses of radioactivity of the used radiopharmaceuticals in order to limit image acquisition duration. The introduction of cadmium-zinc-telluride (CZT)-based cameras may overcome some of the limitations against conventional gamma cameras. CZT cameras used for the evaluation of myocardial perfusion have been shown to have a higher count sensitivity compared to conventional single photon emission computed tomography (SPECT) techniques. CZT image quality is further improved by the development of a dedicated three-dimensional iterative reconstruction algorithm, based on maximum likelihood expectation maximization (MLEM), which corrects for the loss in spatial resolution due to line response function of the collimator. All these innovations significantly reduce imaging time and result in a lower patient's radiation exposure compared with standard SPECT. To guide current and possible future users of the CZT technique for myocardial perfusion imaging, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, has decided to examine the current literature regarding procedures and clinical data on CZT cameras. The committee hereby aims 1) to identify the main acquisitions protocols; 2) to evaluate the diagnostic and prognostic value of CZT derived myocardial perfusion, and finally 3) to determine the impact of CZT on radiation exposure.

  13. Three dimensional nonlinear simulations of edge localized modes on the EAST tokamak using BOUT++ code

    NASA Astrophysics Data System (ADS)

    Liu, Z. X.; Xu, X. Q.; Gao, X.; Xia, T. Y.; Joseph, I.; Meyer, W. H.; Liu, S. C.; Xu, G. S.; Shao, L. M.; Ding, S. Y.; Li, G. Q.; Li, J. G.

    2014-09-01

    Experimental measurements of edge localized modes (ELMs) observed on the EAST experiment are compared to linear and nonlinear theoretical simulations of peeling-ballooning modes using the BOUT++ code. Simulations predict that the dominant toroidal mode number of the ELM instability becomes larger for lower current, which is consistent with the mode structure captured with visible light using an optical CCD camera. The poloidal mode number of the simulated pressure perturbation shows good agreement with the filamentary structure observed by the camera. The nonlinear simulation is also consistent with the experimentally measured energy loss during an ELM crash and with the radial speed of ELM effluxes measured using a gas puffing imaging diagnostic.

  14. Interaction Between a Steady Detonation Wave in Nitromethane and Geometrical Complex Confinement Defects

    NASA Astrophysics Data System (ADS)

    Crouzet, B.; Soulard, L.; Carion, N.; Manczur, P.

    2007-12-01

    Two copper cylinder expansion tests were carried out on nitromethane. They differ from the classical cylinder test in that the liner includes evenly-spaced protruding circular defects. The aim is to study how a detonation front propagating in the liquid explosive interacts with the confining material defects. The subsequent motion of the metal, accelerated by the expanding detonation products, is measured using a range of diagnostic techniques: electrical probes, a rapid framing camera, a glass block associated with a streak camera and velocity laser interferometers. The different experimental records have been examined in the light of previous classical cylinder test measurements, simple 2D theoretical shock polar analysis results and 2D numerical simulations.

  15. Application of multispectral color photography to flame flow visualization

    NASA Technical Reports Server (NTRS)

    Stoffers, G.

    1979-01-01

    For flames of short duration and low intensity of radiation a spectroscopical flame diagnostics is difficult. In order to find some other means of extracting information about the flame structure from its radiation, the feasibility of using multispectral color photography was successfully evaluated. Since the flame photographs are close-ups, there is a considerable parallax between the single images, when several cameras are used, and additive color viewing is not possible. Each image must be analyzed individually, it is advisable to use color film in all cameras. One can either use color films of different spectral sensitivities or color films of the same type with different color filters. Sharp cutting filters are recommended.

  16. Multiple-frame IR photo-recorder KIT-3M

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roos, E; Wilkins, P; Nebeker, N

    2006-05-15

    This paper reports the experimental results of a high-speed multi-frame infrared camera which has been developed in Sarov at VNIIEF. Earlier [1] we discussed the possibility of creation of the multi-frame infrared radiation photo-recorder with framing frequency about 1 MHz. The basis of the photo-recorder is a semiconductor ionization camera [2, 3], which converts IR radiation of spectral range 1-10 micrometers into a visible image. Several sequential thermal images are registered by using the IR converter in conjunction with a multi-frame electron-optical camera. In the present report we discuss the performance characteristics of a prototype commercial 9-frame high-speed IR photo-recorder.more » The image converter records infrared images of thermal fields corresponding to temperatures ranging from 300 C to 2000 C with an exposure time of 1-20 {micro}s at a frame frequency up to 500 KHz. The IR-photo-recorder camera is useful for recording the time evolution of thermal fields in fast processes such as gas dynamics, ballistics, pulsed welding, thermal processing, automotive industry, aircraft construction, in pulsed-power electric experiments, and for the measurement of spatial mode characteristics of IR-laser radiation.« less

  17. LightDenseYOLO: A Fast and Accurate Marker Tracker for Autonomous UAV Landing by Visible Light Camera Sensor on Drone.

    PubMed

    Nguyen, Phong Ha; Arsalan, Muhammad; Koo, Ja Hyung; Naqvi, Rizwan Ali; Truong, Noi Quang; Park, Kang Ryoung

    2018-05-24

    Autonomous landing of an unmanned aerial vehicle or a drone is a challenging problem for the robotics research community. Previous researchers have attempted to solve this problem by combining multiple sensors such as global positioning system (GPS) receivers, inertial measurement unit, and multiple camera systems. Although these approaches successfully estimate an unmanned aerial vehicle location during landing, many calibration processes are required to achieve good detection accuracy. In addition, cases where drones operate in heterogeneous areas with no GPS signal should be considered. To overcome these problems, we determined how to safely land a drone in a GPS-denied environment using our remote-marker-based tracking algorithm based on a single visible-light-camera sensor. Instead of using hand-crafted features, our algorithm includes a convolutional neural network named lightDenseYOLO to extract trained features from an input image to predict a marker's location by visible light camera sensor on drone. Experimental results show that our method significantly outperforms state-of-the-art object trackers both using and not using convolutional neural network in terms of both accuracy and processing time.

  18. Compton camera study for high efficiency SPECT and benchmark with Anger system

    NASA Astrophysics Data System (ADS)

    Fontana, M.; Dauvergne, D.; Létang, J. M.; Ley, J.-L.; Testa, É.

    2017-12-01

    Single photon emission computed tomography (SPECT) is at present one of the major techniques for non-invasive diagnostics in nuclear medicine. The clinical routine is mostly based on collimated cameras, originally proposed by Hal Anger. Due to the presence of mechanical collimation, detection efficiency and energy acceptance are limited and fixed by the system’s geometrical features. In order to overcome these limitations, the application of Compton cameras for SPECT has been investigated for several years. In this study we compare a commercial SPECT-Anger device, the General Electric HealthCare Infinia system with a High Energy General Purpose (HEGP) collimator, and the Compton camera prototype under development by the French collaboration CLaRyS, through Monte Carlo simulations (GATE—GEANT4 Application for Tomographic Emission—version 7.1 and GEANT4 version 9.6, respectively). Given the possible introduction of new radio-emitters at higher energies intrinsically allowed by the Compton camera detection principle, the two detectors are exposed to point-like sources at increasing primary gamma energies, from actual isotopes already suggested for nuclear medicine applications. The Compton camera prototype is first characterized for SPECT application by studying the main parameters affecting its imaging performance: detector energy resolution and random coincidence rate. The two detector performances are then compared in terms of radial event distribution, detection efficiency and final image, obtained by gamma transmission analysis for the Anger system, and with an iterative List Mode-Maximum Likelihood Expectation Maximization (LM-MLEM) algorithm for the Compton reconstruction. The results show for the Compton camera a detection efficiency increased by a factor larger than an order of magnitude with respect to the Anger camera, associated with an enhanced spatial resolution for energies beyond 500 keV. We discuss the advantages of Compton camera application for SPECT if compared to present commercial Anger systems, with particular focus on dose delivered to the patient, examination time, and spatial uncertainties.

  19. Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, J., E-mail: chenjie@ucla.edu; State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074; Ding, W. X.

    2016-11-15

    Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbationsmore » have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.« less

  20. Diagnostics and results from coaxial plasma gun development for the PLX- α project

    NASA Astrophysics Data System (ADS)

    Case, A.; Brockington, S.; Cruz, E.; Witherspoon, F. D.

    2016-10-01

    We present results from the diagnostics used during development of the contoured gap coaxial plasma guns for the PLX- α project at LANL. Plasma-jet diagnostics include fast photodiodes for velocimetry, a ballistic pendulum for total plasmoid momentum, and interferometry for line integrated density. Deflectometry will be used for line integrated perpendicular density gradients. Time-resolved high-resolution spectroscopy using a novel detector and time-integrated survey spectroscopy are used for measurements of velocity and temperature, as well as impurities. We will also use a Faraday cup for density, fast imaging for plume geometry, and time-integrated imaging for overall light emission. Experimental results are compared to the desired target parameters for the plasma jets (up to n 2 ×1016cm-3 , v 50km / s , mass 5gm , radius = 4cm , and length 10cm). This work supported by the ARPA-E ALPHA Program.

Top