Sample records for fast set putty

  1. Moldable setting time evaluation between sodium alginate and bovine gelatine of glutinous rice mixture as dental putty materials

    NASA Astrophysics Data System (ADS)

    Takarini, V.; Hasratiningsih, Z.; Karlina, E.; Febrida, R.; Asri, L. A. T. W.; Purwasasmita, BS

    2017-02-01

    Putty elastomeric material is a viscous, moldable material that can be used as a dental impression to record and duplicate the tooth structure. Commercially available putty materials are hardly found in the Indonesian market. The aim of this work is to develop an alternative putty dental material from glutinous rice with two different gelling agents; sodium alginate and bovine gelatine. A commercially putty material was used as a control. The length of time required for the putty materials to set (setting time) was evaluated with compression set test. The result showed that sodium alginate and bovine gelatine gelling agents resulted in moldable putty materials that comparable to the commercial product. Glutinous rice mixed with sodium alginate gelling agent demonstrated longer setting time (more than 1 hours) compared to bovine gelatine (6 minutes). These may occur due to heat treatment applied to the bovine gelatine, while sodium alginate mixture has a chemical reaction since CaCl2 crosslink agent had been added to the mixture. Glutinous rice with bovine gelatine mixture is a promising candidate to be used as a dental putty material.

  2. A comparison of resistance to fracture among four commercially available forms of hydroxyapatite cement.

    PubMed

    Miller, Lee; Guerra, Aldo Benjamin; Bidros, Rafi Sirop; Trahan, Christopher; Baratta, Richard; Metzinger, Stephen Eric

    2005-07-01

    Hydroxyapatite cement is a relatively new biomaterial that has found widespread use in craniomaxillofacial surgery. Despite its common usage, complication rates as high as 32% have been reported. When failed implants are removed, implant fracture has been cited as a potential cause of failure. The purpose of this study was to evaluate resistance to fracture among 4 commercially available hydroxyapatite cement formulations. The materials tested included Norian Craniofacial Repair System (carbonated apatite cement) (AO North America, Devon, PA), Norian CRS Fast Set Putty (carbonated apatite cement) (AO North America), BoneSource (hydroxyapatite cement) (Stryker Leibinger, Portage, MI), and Mimix (hydroxyapatite cement) (Walter Lorenz Surgical, Inc, Jacksonville, FL). To ensure consistency, all materials were embedded in acrylic wells. Each material was placed into a well 2.54 cm in diameter and 0.953 cm in thickness. The materials were prepared per manufacturer specifications. All materials were incubated at 37.0 degrees C, in 6% CO2, 100% humidity for 36 hours. Using the Bionix MTS Test System, a 12-mm-diameter probe applied incremental force to the center of the disk at a rate of 0.1 mm per second. The transmitted force was measured using a Bionix MTS Axial-Torsional Load Transducer for each disk. The force which resulted in fracture was recorded for each material. Ten disks of each material were processed by this method, for a total of 40 disks. The significance of resistance to fracture for the 4 compounds was analyzed using 1-way analysis of variance with post hoc Scheffe method. Mean fracture force with related P values was plotted for direct comparison of group outcomes. Material type contributed significantly to variance in fracture force for the biomaterials studied. Norian CRS required the greatest mean fracture force (1385 N, SD+/-292 N), followed by Norian CRS Fast Set Putty (1143 N, SD+/-193 N). Mimix required a mean fracture force of 740 N, SD+/-79 N. BoneSource required a mean fracture force of 558 N, SD+/-150 N. Mimix and BoneSource required significantly less force for fracture when compared with Norian CRS and Fast Set Putty (P<0.01). Comparisons of fracture load resistance between 4 commonly used bone substitute materials have not been previously reported. Increasing biomaterial strength may reduce complications resulting from reinjury to cranioplasty sites. In this model, Norian CRS and Norian CRS Fast Set Putty demonstrated a significantly greater resistance to fracture when compared with BoneSource and Mimix.

  3. Effects of neutral sodium hydrogen phosphate on setting reaction and mechanical strength of hydroxyapatite putty.

    PubMed

    Ishikawa, K; Miyamoto, Y; Takechi, M; Ueyama, Y; Suzuki, K; Nagayama, M; Matsumura, T

    1999-03-05

    The setting reaction and mechanical strength in terms of diametral tensile strength (DTS) of hydroxyapatite (HAP) putty made of tetracalcium phosphate, dicalcium phosphate anhydrous, and neutral sodium hydrogen phosphate (Na1.8H1.2PO4) solution containing 8 wt % sodium alginate were evaluated as a function of the Na1.8H1.2PO4 concentration. In one condition, HAP putty was placed in an incubator kept at 37 degrees C and 100% relative humidity. In the other condition, immediately after mixing HAP putty was immersed in serum kept at 37 degrees C. Longer setting times and lower DTS values were observed when HAP putty was immersed in serum regardless of the Na1.8H1.2PO4 concentration. The setting times of the HAP putty in both conditions became shorter with an increase in the Na1. 8H1.2PO4 concentration, reaching approximately 7-13 min when the Na1. 8H1.2PO4 concentration was 0.6 mol/L or higher. The DTS value of HAP putty was relatively constant (10 MPa) regardless of the Na1.8H1. 2PO4 concentration (0.2-1.0 mol/L) when HAP putty was kept in an incubator. In contrast, when HAP putty was immersed in serum, the DTS value was dependent on the Na1.8H1.2PO4 concentration. It increased with the Na1.8H1.2PO4 concentration and reached approximately 5 MPa when the Na1.8H1.2PO4 concentration was 0.6 mol/L, after which it showed a relatively constant DTS value. We therefore would recommend a HAP putty that uses 0.6 mol/L Na1.8H1. 2PO4 since at that concentration the putty's setting time (approximately 10 min) is proper for clinical use and it shows good DTS value (approximately 5 MPa) even when it is immersed in serum immediately after mixing. Copyright 1999 John Wiley & Sons, Inc.

  4. Osteogenic potential of the human bone morphogenetic protein 2 gene activated nanobone putty.

    PubMed

    Tian, Xiao-bin; Sun, Li; Yang, Shu-hua; Zhang, Yu-kun; Hu, Ru-yin; Fu, De-hao

    2008-04-20

    Nanobone putty is an injectable and bioresorbable bone substitute. The neutral-pH putty resembles hard bone tissue, does not contain polymers or plasticizers, and is self-setting and nearly isothermic, properties which are helpful for the adhesion, proliferation, and function of bone cells. The aim of this study was to investigate the osteogenic potential of human bone morphogenetic protein 2 (hBMP2) gene activated nanobone putty in inducing ectopic bone formation, and the effects of the hBMP2 gene activated nanobone putty on repairing bone defects. Twenty four Kunming mice were randomly divided into two groups. The nanobone putty + hBMP2 plasmid was injected into the right thigh muscle pouches of the mice (experiment side). The nanobone putty + blank plasmid or nanobone putty was injected into the left thigh muscle pouches of the group 1 (control side 1) or group 2 (control side 2), respectively. The effects of ectopic bone formation were evaluated by radiography, histology, and molecular biology analysis at 2 and 4 weeks after operation. Bilateral 15 mm radial defects were made in forty-eight rabbits. These rabbits were randomly divided into three groups: Group A, nanobone putty + hBMP2 plasmid; Group B, putty + blank plasmid; Group C, nanobone putty only. Six rabbits with left radial defects served as blank controls. The effect of bone repairing was evaluated by radiography, histology, molecular biology, and biomechanical analysis at 4, 8, and 12 weeks after operation. The tissue from the experimental side of the mice expressed hBMP2. Obvious cartilage and island-distributed immature bone formation in implants of the experiment side were observed at 2 weeks after operation, and massive mature bone observed at 4 weeks. No bone formation was observed in the control side of the mice. The ALP activity in the experiment side of the mice was higher than that in the control side. The tissue of Group A rabbits expressed hBMP2 protein and higher ALP level. The new bone formation rate and antibending strength of group A was significantly higher than those of group B and C. The defects in blank control were not healed. The hBMP2 gene activated nanobone putty exhibited osteoinductive ability, and had a better bone defect repair capability than that of nanobone putty only.

  5. Effect of five brands of latex gloves on the setting time of polyvinyl siloxane putty impression materials.

    PubMed

    Ravikumar, C M; Sangur, Rajashekar

    2012-01-01

    Addition silicone impression materials have been used as impression material for more than 20 years. Although they are among the most expensive impression materials, they became popular during the past decade as they have excellent physical properties. Prevention of infection is an important aspect in dental treatment since dental professionals are routinely exposed to the wide variety of microorganisms present in saliva. Gloves are the most common protective measure used during dental treatment. The gloves are mostly made of latex. In this study, we examine how the setting time of three types polyvinyl putty materials were affected by the use of five different brands of latex gloves and one brand of vinyl gloves. Each material was first mixed without wearing gloves according to the manufacturer's instructions. After the stipulated mixing time, the setting time was measured using the Vicat needle. The setting time is measured from the time of mixing till the time that the needle does not produce any indentation on the surface of the material. The putty material was then mixed with gloved hands (using the five different brands of latex gloves in turn) and the setting time was measured. Then the material was mixed with washed gloved hands, and the setting time was measured again. Finally, the material was mixed with vinyl gloved hands and the setting time was measured. The following conclusions were drawn from the study: Reprosil and Express showed significant variation in the setting time with the latex gloved hands.There was no significant variation in the setting time when material was mixed with unwashed vs washed gloved hands.Vinyl gloves did not significantly affect the setting time of any of the putty impression materials.

  6. PuTTY | High-Performance Computing | NREL

    Science.gov Websites

    PuTTY PuTTY Learn how to use PuTTY to connect to NREL's high-performance computing (HPC) systems . Connecting When you start the PuTTY app, the program will display PuTTY's Configuration menu. When this comes . When prompted, type your password again followed by . Note: to increase

  7. Properties of calcium silicate-monobasic calcium phosphate materials for endodontics containing tantalum pentoxide and zirconium oxide.

    PubMed

    Zamparini, Fausto; Siboni, Francesco; Prati, Carlo; Taddei, Paola; Gandolfi, Maria Giovanna

    2018-05-08

    The aim of the study was to evaluate chemical-physical properties and apatite-forming ability of three premixed calcium silicate materials containing monobasic calcium phosphate (CaH 4 P 2 O 8 ) bioceramic, tantalum pentoxide and zirconium oxide, recently marketed for endodontics (TotalFill BC-Sealer, BC-RRM-Paste, BC-RRM-Putty). Microchemical and micromorphological analyses, radiopacity, initial and final setting times, calcium release and alkalising activity were tested. The nucleation of calcium phosphates (CaPs) and/or apatite after 28 days ageing was evaluated by ESEM-EDX and micro-Raman spectroscopy. BC-Sealer and BC-RRM-Paste showed similar initial (23 h), prolonged final (52 h) setting times and good radiopacity (> 7 mm Al); BC-RRM-Putty showed fast initial (2 h) and final setting times (27 h) and excellent radiopacity (> 9 mm Al). All materials induced a marked alkalisation (pH 11-12) up to 28 days and showed the release of calcium ions throughout the entire test period (cumulative calcium release 641-806 ppm). After 28 days ageing, a well-distributed mineral layer was present on all samples surface; EDX demonstrated relevant calcium and phosphorous peaks. B-type carbonated apatite and calcite deposits were identified by micro-Raman spectroscopy on all the 28-day-aged samples; the deposit thickness was higher on BC-RRM-Paste and BC-RRM-Putty, in agreement with calcium release data. These materials met the required chemical and physical standards and released biologically relevant ions. The CaSi-CaH 4 P 2 O 8 system present in the materials provided Ca and OH ions release with marked abilities to nucleate a layer of B-type carbonated apatite favoured/accelerated by the bioceramic presence. The ability to nucleate apatite may lead many clinical advantages: In orthograde endodontics, it may improve the sealing ability by the deposition of CaPs at the material-root dentine interface, and in endodontic surgery, it could promote bone and periodontal tissue regeneration. As premixed materials, their application in endodontics may result easier in several complex endodontic situations (apicoectomy, root perforation, presence of wide/wet apices).

  8. Periotest values of implants placed in sockets augmented with calcium phosphosilicate putty graft: a comparative analysis against implants placed in naturally healed sockets.

    PubMed

    Mahesh, Lanka; Narayan, Tv; Kostakis, Georgios; Shukla, Sagrika

    2014-03-01

    To measure implant stability using periotest values of implants placed in sockets augmented with calcium phospho-silicate putty (CPS Putty) as compared with implant stability in naturally healed sockets. Twenty two sockets were implanted with CPS Putty immediately after extraction. The sockets were re-entered after a healing period at 5 to 6 months (average 5.3 months) for implant placement. Periotest values were recorded during implant insertion to assess primary stability. These were compared with the Periotest values of 26 implants placed in 22 patients, with naturally healed sockets. Periotest values were significantly lower in the grafted group, indicating better implant stability in sites grafted with CPS putty. Implant stability seems to be significantly higher in sockets augmented using CPS putty when compared to nongrafted sites. This suggests that socket grafting with CPS putty may enhance the quality of available bone for implantation.

  9. Inorganic particle analysis of dental impression elastomers.

    PubMed

    Carlo, Hugo Lemes; Fonseca, Rodrigo Borges; Soares, Carlos José; Correr, Américo Bortolazzo; Correr-Sobrinho, Lourenço; Sinhoreti, Mário Alexandre Coelho

    2010-01-01

    The aim of this study was to determine quantitatively and qualitatively the inorganic particle fraction of commercially available dental elastomers. The inorganic volumetric fraction of two addition silicones (Reprosil Putty/Fluid and Flexitime Easy Putty/Fluid), three condensation silicones (Clonage Putty/Fluid, Optosil Confort/Xantopren VL and Silon APS Putty/Fluid), one polyether (Impregum Soft Light Body) and one polysulfide (Permlastic Light Body) was accessed by weighing a previously determined mass of each material in water before and after burning samples at 600 ºC, during 3 h. Unsettled material samples were soaked in acetone and chloroform for removal of the organic portion. The remaining filler particles were sputter-coated with gold evaluation of their morphology and size, under scanning electron microscopy (SEM). Flexitime Easy Putty was the material with the highest results for volumetric particle fraction, while Impregum Soft had the lowest values. Silon 2 APS Fluid presented the lowest mean filler size values, while Clonage Putty had the highest values. SEM micrographs of the inorganic particles showed several morphologies - lathe-cut, spherical, spherical-like, sticks, and sticks mixed to lathe-cut powder. The results of this study revealed differences in particle characteristics among the elastometic materials that could lead to different results when testing mechanical properties.

  10. Effect of the preparation of lime putties on their properties.

    PubMed

    Navrátilová, Eva; Tihlaříková, Eva; Neděla, Vilém; Rovnaníková, Pavla; Pavlík, Jaroslav

    2017-12-08

    In the study of lime as the basic component of historical mortars and plasters, four lime putties prepared from various kinds of lime of various granulometry and by various ways of preparation were evaluated. The rheological properties and micro-morphologic changes, growing of calcite crystals, and rate of carbonation were monitored. The lime putty prepared from lump lime achieves the best rheological properties, yield stress 214.7 Pa and plastic viscosity 2.6 Pa·s. The suitability of this lime putty was checked by testing the development of calcium hydroxide and calcite crystals using scanning electron microscopy and environmental scanning electron microscopy. The disordered crystals of calcium hydroxide exhibit better carbonation resulting in the large crystals of calcite; therefore, the mortar prepared from the lump lime has the highest flexural strength and compressive strength 0.8/2.5 MPa, its carbonation is the fastest and exhibits the longest durability. Also, thanks to the micro-morphological characterization of samples in their native state by means of environmental scanning electron microscopy, the new way of lime putty preparation by mixing was proven. The preparation consists in the mechanical crash of the lime particles immediately after hydration. This enables the properties of putty prepared from lump lime to be nearly reached.

  11. Local effect of zoledronic acid on new bone formation in posterolateral spinal fusion with demineralized bone matrix in a murine model.

    PubMed

    Zwolak, Pawel; Farei-Campagna, Jan; Jentzsch, Thorsten; von Rechenberg, Brigitte; Werner, Clément M

    2018-01-01

    Posterolateral spinal fusion is a common orthopaedic surgery performed to treat degenerative and traumatic deformities of the spinal column. In posteriolateral spinal fusion, different osteoinductive demineralized bone matrix products have been previously investigated. We evaluated the effect of locally applied zoledronic acid in combination with commercially available demineralized bone matrix putty on new bone formation in posterolateral spinal fusion in a murine in vivo model. A posterolateral sacral spine fusion in murine model was used to evaluate the new bone formation. We used the sacral spine fusion model to model the clinical situation in which a bone graft or demineralized bone matrix is applied after dorsal instrumentation of the spine. In our study, group 1 received decortications only (n = 10), group 2 received decortication, and absorbable collagen sponge carrier, group 3 received decortication and absorbable collagen sponge carrier with zoledronic acid in dose 10 µg, group 4 received demineralized bone matrix putty (DBM putty) plus decortication (n = 10), and group 5 received DBM putty, decortication and locally applied zoledronic acid in dose 10 µg. Imaging was performed using MicroCT for new bone formation assessment. Also, murine spines were harvested for histopathological analysis 10 weeks after surgery. The surgery performed through midline posterior approach was reproducible. In group with decortication alone there was no new bone formation. Application of demineralized bone matrix putty alone produced new bone formation which bridged the S1-S4 laminae. Local application of zoledronic acid to demineralized bone matrix putty resulted in significant increase of new bone formation as compared to demineralized bone matrix putty group alone. A single local application of zoledronic acid with DBM putty during posterolateral fusion in sacral murine spine model increased significantly new bone formation in situ in our model. Therefore, our results justify further investigations to potentially use local application of zoledronic acid in future clinical studies.

  12. Dimensional accuracy of resultant casts made by a monophase, one-step and two-step, and a novel two-step putty/light-body impression technique: an in vitro study.

    PubMed

    Caputi, Sergio; Varvara, Giuseppe

    2008-04-01

    Dimensional accuracy when making impressions is crucial to the quality of fixed prosthodontic treatment, and the impression technique is a critical factor affecting this accuracy. The purpose of this in vitro study was to compare the dimensional accuracy of a monophase, 1- and 2-step putty/light-body, and a novel 2-step injection impression technique. A stainless steel model with 2 abutment preparations was fabricated, and impressions were made 15 times with each technique. All impressions were made with an addition-reaction silicone impression material (Aquasil) and a stock perforated metal tray. The monophase impressions were made with regular body material. The 1-step putty/light-body impressions were made with simultaneous use of putty and light-body materials. The 2-step putty/light-body impressions were made with 2-mm-thick resin-prefabricated copings. The 2-step injection impressions were made with simultaneous use of putty and light-body materials. In this injection technique, after removing the preliminary impression, a hole was made through the polymerized material at each abutment edge, to coincide with holes present in the stock trays. Extra-light-body material was then added to the preliminary impression and further injected through the hole after reinsertion of the preliminary impression on the stainless steel model. The accuracy of the 4 different impression techniques was assessed by measuring 3 dimensions (intra- and interabutment) (5-mum accuracy) on stone casts poured from the impressions of the stainless steel model. The data were analyzed by 1-way ANOVA and Student-Newman-Keuls test (alpha=.05). The stone dies obtained with all the techniques had significantly larger dimensions as compared to those of the stainless steel model (P<.01). The order for highest to lowest deviation from the stainless steel model was: monophase, 1-step putty/light body, 2-step putty/light body, and 2-step injection. Significant differences among all of the groups for both absolute dimensions of the stone dies, and their percent deviations from the stainless steel model (P<.01), were noted. The 2-step putty/light-body and 2-step injection techniques were the most dimensionally accurate impression methods in terms of resultant casts.

  13. Call Combinations in Monkeys: Compositional or Idiomatic Expressions?

    ERIC Educational Resources Information Center

    Arnold, Kate; Zuberbuhler, Klaus

    2012-01-01

    Syntax is widely considered the feature that most decisively sets human language apart from other natural communication systems. Animal vocalisations are generally considered to be holistic with few examples of utterances meaning something other than the sum of their parts. Previously, we have shown that male putty-nosed monkeys produce call…

  14. Two-step impression/ injection, an alternative putty/ wash impression technique: case report.

    PubMed

    Caputi, S; Murmura, G; Sinjari, B; Varvara, G

    2012-01-01

    We here describe a new technique for making a definitive impression that we refer to as the two-step impression/injection technique. This technique initially follows the classical one-step putty/ light-body impression technique with the polymerization of the putty and the light-body compound. This is then followed by the second step: injection of extra-light-body compound into the preparation through a hole in the metal stock tray. The aim of this additional step is to control the wash bulk and minimize the changes that can produce unfavorable impression results. This new two-step impression/injection technique allows displacement of soft tissues, such as the tongue, during the first seating of the putty and wash materials, while in the second step, the extra-light-body compound records all of the finer details without being compressed.

  15. Comparative Analysis of Calcium Silicate-based Root Filling Materials Using an Open Apex Model.

    PubMed

    Tran, Dennis; He, Jianing; Glickman, Gerald N; Woodmansey, Karl F

    2016-04-01

    Many new calcium silicate-based root filling materials have emerged in the market; however, their performance in the orthograde obturation of an open apex has not been evaluated. The purpose of this study was to compare the marginal adaptation of ProRoot MTA (Dentsply Tulsa Dental, Tulsa, OK), NeoMTA Plus (Avalon Biomed Inc, Bradenton, FL), and Endosequence BC RRM-Fast Set Putty (BC RRM-FS; Brasseler USA, Savannah, GA) after orthograde placement in roots with open apices. Palatal roots of maxillary molars were instrumented to create divergent open apices and divided into 4 groups for orthograde obturation: ProRoot MTA, NeoMTA Plus, BC RRM-FS, and BC RRM-FS + BC Sealer. Using a scanning electron microscope, the quality of material adaptation at the anatomic apex was evaluated by 5 blinded examiners; 3 mm of the root end was sectioned, and gap distance was measured at the material-dentin interface. Statistical analyses were performed using the Kruskal-Wallis test. There were no significant differences in marginal adaptation among the 4 groups at the level of the anatomic apex (P = .175). BC RRM-FS + BC Sealer had a significantly smaller gap size after 3-mm root end resection compared with the other 3 groups (P < .01). No differences were observed among the other 3 materials. All materials showed comparable marginal adaptation at the anatomic apex when used for orthograde obturation of open apices. Application of BC Sealer before the delivery of BC RRM-FS Putty enhanced the quality of adaptation coronal to the apex. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Accuracy of a reformulated fast-set vinyl polysiloxane impression material using dual-arch trays.

    PubMed

    Kang, Alex H; Johnson, Glen H; Lepe, Xavier; Wataha, John C

    2009-05-01

    A common technique used for making crown impressions involves use of a vinyl polysiloxane impression material in combination with a dual-arch tray. A leading dental manufacturer has reformulated its vinyl polysiloxane (VPS) impression line, but the accuracy of the new material has not been verified. The purpose of this study was to assess the accuracy of reformulated VPS impression materials using the single-step dual-arch impression technique. Dual-arch impressions were made on a typodont containing a master stainless steel standard crown preparation die, from which gypsum working dies were formed, recovered, and measured. The impression materials evaluated were Imprint 3 Penta Putty with Quick Step Regular Body (IP-0); Imprint 3 Penta Quick Step Heavy Body with Quick Step Light Body (IP-1); Aquasil Ultra Rigid Fast Set with LV Fast Set (AQ-1); and Aquasil Ultra Heavy Fast Set with XLV Fast Set (AQ-2) (n=10). All impressions were disinfected with CaviCide spray for 10 minutes prior to pouring with type IV gypsum. Buccolingual (BL), mesiodistal (MD), and occlusogingival (OG) dimensions were measured and compared to the master die using an optical measuring microscope. Linear dimensional change was also assessed for IP-0 and AQ-1 at 1 and 24 hours based on ANSI/ADA Specification No. 19. Single-factor ANOVA with Dunnett's T3 multiple comparisons was used to compare BL, MD, and OG changes, with hypothesis testing at alpha=.05. A repeated-measures ANOVA was used to compare linear dimensional changes. There were statistical differences among the 4 impression systems for 3 of 4 dimensions of the master die. IP-0 working dies were significantly larger in MD and OG-L dimensions but significantly smaller in the BL dimension. IP-1 working dies were significantly smaller in the BL dimension compared to the master die. With the exception of IP-0, differences detected were small and clinically insignificant. No significant differences were observed for linear dimensional change. The single-step dual-arch impression technique produced working dies that were smaller in 3 of the 4 dimensions measured and may require additional die relief to achieve appropriate fit of cast restorations. Overall accuracy was acceptable for all impression groups with the exception of IP-0.

  17. Effect of various putty-wash impression techniques on marginal fit of cast crowns.

    PubMed

    Nissan, Joseph; Rosner, Ofir; Bukhari, Mohammed Amin; Ghelfan, Oded; Pilo, Raphael

    2013-01-01

    Marginal fit is an important clinical factor that affects restoration longevity. The accuracy of three polyvinyl siloxane putty-wash impression techniques was compared by marginal fit assessment using the nondestructive method. A stainless steel master cast containing three abutments with three metal crowns matching the three preparations was used to make 45 impressions: group A = single-step technique (putty and wash impression materials used simultaneously), group B = two-step technique with a 2-mm relief (putty as a preliminary impression to create a 2-mm wash space followed by the wash stage), and group C = two-step technique with a polyethylene spacer (plastic spacer used with the putty impression followed by the wash stage). Accuracy was assessed using a toolmaker microscope to measure and compare the marginal gaps between each crown and finish line on the duplicated stone casts. Each abutment was further measured at the mesial, buccal, and distal aspects. One-way analysis of variance was used for statistical analysis. P values and Scheffe post hoc contrasts were calculated. Significance was determined at .05. One-way analysis of variance showed significant differences among the three impression techniques in all three abutments and at all three locations (P < .001). Group B yielded dies with minimal gaps compared to groups A and C. The two-step impression technique with 2-mm relief was the most accurate regarding the crucial clinical factor of marginal fit.

  18. When Is Melting Not Really Melting?

    ERIC Educational Resources Information Center

    Mangiaracina, Mike

    2017-01-01

    This 5E cycle of lessons takes students through a fun and thorough study of Silly Putty's properties, progressing from an initial observation of a "melting snowman" toy in the Engage phase to making and "marketing" their own homemade putty in the Evaluate phase. Along the way, students use evidence to construct their own…

  19. Histomorphometric evaluation of a calcium-phosphosilicate putty bone substitute in extraction sockets.

    PubMed

    Kotsakis, Georgios A; Joachim, Frederic P C; Saroff, Stephen A; Mahesh, Lanka; Prasad, Hari; Rohrer, Michael D

    2014-01-01

    The objective of this study was to evaluate bone regeneration in 24 sockets grafted with a calcium phosphosilicate putty alloplastic bone substitute. A core was obtained from 17 sockets prior to implant placement for histomorphometry at 5 to 6 months postextraction. Radiographic analysis during the same postextraction healing period showed radiopaque tissue in all sockets. Histomorphometric analysis revealed a mean vital bone content of 31.76% (± 14.20%) and residual graft content of 11.47% (± 8.99%) after a mean healing period of 5.7 months. The high percentage of vital bone in the healed sites in combination with its timely absorption rate suggest that calcium phosphosilicate putty can be a reliable choice for osseous regeneration in extraction sockets.

  20. Effectiveness of the addition of Lidocaine to a hemostatic, bioresorbable putty in the treatment of iliac crest donor site pain.

    PubMed

    Müller, Marc Andreas; Mehrkens, Arne; Zürcher, Roman; Vavken, Patrick; Valderrabano, Victor

    2014-12-08

    The harvest of iliac crest bone grafts (ICBG) is associated with relevant donor site pain, but may be lowered by the application of lidocaine loaded on biodegradable, hemostatic putty for sustained local analgesic release. The goal of this double-blind controlled trial was to assess the efficacy of adding lidocaine to a hemostatic putty (Orthostat ™) to treat donor site pain following harvest of ICBG in foot and ankle procedures. After ICBG harvest during a foot and ankle procedure, the resulting bone defect was either filled with Orthostat™ (n = 7) or with the same hemostatic putty loaded with lidocaine (Orthostat-L™, n = 7). During the first 72 postoperative hours, donor site and surgical site pain were managed by patient controlled morphine delivery and a peripheral nerve block. Donor site pain was periodically quantified on a Visual Analog (VAS) and a Wong Baker FACES scale. Pain scores were plotted over time to calculate the area under the curve (AUC) to quantify the overall pain experienced in specific time intervals. Orthostat-L™ significantly reduced donor site pain over the first 12 hours postoperatively as evidenced by a significant decrease of the AUC in both VAS (p = 0.0366) and Wong Baker FACES pain score plots (p = 0.0024). Cumulated morphine uses were not significantly decreased with Orthostat-L™. The addition of lidocaine to a hemostatic putty offers a significant ICBG donor site pain reduction over the first 12 postoperative hours. ClinicalTrials.gov NCT01504035. Registered January 2nd 2012.

  1. The use of dental putty in the assessment of hard surfaces within paved urban areas that may leave defined or patterned marks on bodies.

    PubMed

    Johnson, Oliver Ross; Lyall, Matt; Johnson, Christopher Paul

    2015-04-01

    The identification of a patterned skin or scalp mark at autopsy can provide key forensic evidence in identifying an injury that may have been left by an assailant's footwear. It is also important to consider whether such a mark could alternatively have been left by the deceased coming into forceful contact with a hard surface at the scene of an incident, for example by falling. This study was designed to demonstrate how variable surfaces are within paved urban areas, including those which might leave marks resembling footwear patterns, and to evaluate whether dental putty impression lifting is a practical and effective adjunct to photography in assessing patterned surfaces. Eighteen 'scenes' of approximately 50 m² were assessed for different hard surfaces by photography and by the production of dental putty impression lifts. The number of hard surfaces varied between 4 and 12 per scene, with 90% (122/135) of all hard surfaces deemed likely to leave distinct marking on skin with forceful contact and 46% (62/135) a defined/regular mark potentially similar to a footwear injury (mean = 3.4 per scene). Dental putty proved to be an excellent tool in characterising hard surfaces, producing firm but slightly flexible lifts that can be used in combination with a commercially available inkless footwear impression kit to generate transparencies that help facilitate detailed comparison work. Whenever a potential footwear mark is identified at autopsy, a systematic examination of all hard surfaces at the scene is mandatory, and this process will be significantly strengthened by the use of dental putty. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  2. Passive damping concepts for free and forced member and grillage vibration

    NASA Technical Reports Server (NTRS)

    Razzaq, Zia; Najjar, Bassam

    1988-01-01

    The performance of potential passive damping concepts is investigted for a long tubular aluminum alloy member, and a two-bar grillage structure. The members are restrained partially at the ends and are of the type being considered by NASA for possible use in the construction of a future space station. Four different passive damping concepts are studied and include nylon brush, wool swab, copper brush, and silly putty in chamber dampers. Both free and forced vibration tests are conducted. It is found that the silly putty in chamber damper concept provides considerably greater passive damping as compared to that of the other three concepts. For the grillage natural vibration, a five wool swab damper configuration provides greater damping than the five silly putty dampers in chamber configuration. Due to the constrained motion imposed by the vibrator used in the tests, the effectiveness of the passive dampers could not be adequately evaluated for the individual member. However, it is found that for the grillage under forced vibration, the five silly putty dampers in chamber damper configuration provides very effective passive damping although only at and around the resonant frequency. At resonance, these dampers provide a 51 percent reduction in the dynamic magnification factor for this case.

  3. Clinical observation of biomimetic mineralized collagen artificial bone putty for bone reconstruction of calcaneus fracture

    PubMed Central

    Pan, Yong-Xiong; Yang, Guang-Gang; Li, Zhong-Wan; Shi, Zhong-Min; Sun, Zhan-Dong

    2018-01-01

    Abstract This study investigated clinical outcomes of biomimetic mineralized collagen artificial bone putty for bone reconstruction in the treatment of calcaneus fracture. Sixty cases of calcaneal fractures surgically treated with open reduction and internal fixation in our hospital from June 2014–2015 were chosen and randomly divided into two groups, including 30 cases treated with biomimetic mineralized collagen artificial bone putty as treatment group, and 30 cases treated with autogenous ilia as control group. The average follow-up time was 17.2 ± 3.0 months. The results showed that the surgery duration and postoperative drainage volume of treatment group were significantly lower than control group; there were no statistically significant differences in the fracture healing time, American Orthopaedic Foot and Ankle Society scores at 3 and 12 months after surgery, Böhler’s angle, Gissane’s angle and height of calcaneus between the two groups. There were no significant differences in wound complication and reject reaction between the two groups, while significant difference in donor site complication. As a conclusion, the implantation of biomimetic mineralized collagen artificial bone putty in the open reduction of calcaneal fracture resulted in reliable effect and less complications, which is suitable for clinical applications in the treatment of bone defect in calcaneal fractures. PMID:29644087

  4. A clinical investigation of demineralized bone matrix putty for treatment of periodontal bony defects in humans.

    PubMed

    Banjar, Arwa Ahmed; Mealey, Brian L

    2013-01-01

    The goal of this study was to evaluate the effectiveness of demineralized bone matrix (DBM) putty, consisting of demineralized human bone allograft matrix in a carrier of bovine collagen and alginate, for the treatment of periodontal defects in humans. Twenty subjects with at least one site having a probing depth ≥ 6 mm and radiographic evidence of bony defect depth > 3 mm were included. The infrabony defects were grafted with DBM putty bone graft. The following clinical parameters were assessed at baseline and 6 months posttreatment: probing depth (PD), gingival recession (GR), and clinical attachment level (CAL). Bone fill was evaluated using transgingival probing and standardized radiographs taken at baseline and 6 months posttreatment. The 6-month evaluation showed a significant PD reduction of 3.27 ± 1.67 mm and clinical attachment gain of 2.27 ± 1.74 mm. Bone sounding measurements showed a mean clinical bone defect fill of 2.93 ± 1.87 mm and a mean radiographic bone fill of 2.55 ± 2.31 mm. The use of DBM putty was effective for treatment of periodontal bony defects in humans. Significant improvement in CAL, PD, and bone fill was observed at 6 months compared to baseline.

  5. Esthetic management of a primary double tooth using a silicone putty guide: a case report.

    PubMed

    Agarwal, Ravi; Chaudhry, Kalpna; Yeluri, Ramakrishna; Munshi, Autar Krishen

    2013-03-01

    The term double tooth is often used to describe fusion and gemination. The development of isolated large or joined teeth is not rare, but the literature is confusing when the appropriate terminology is presented. The objective of this paper is to present a case of a primary double tooth in a 5-year-old girl with a history of trauma. The tooth was endodontically treated and esthetic management was carried out using a silicone putty guide.

  6. Experimental and theoretical investigation of passive damping concepts for member forced and free vibration

    NASA Technical Reports Server (NTRS)

    Razzaq, Zia; Mykins, David W.

    1987-01-01

    Potential passive damping concepts for use in space structures are identified. The effectiveness of copper brush, wool swab, and silly putty in chamber dampers is investigated through natural vibration tests on a tubular aluminum member. The member ends have zero translation and possess partial rotational restraints. The silly putty in chamber dampers provide the maximum passive damping efficiency. Forced vibration tests are then conducted with one, two, and three damper chambers containing silly putty. Owing to the limitation of the vibrator used, the performance of these dampers could not be evaluated experimentally until the forcing function was disengaged. Nevertheless, their performance is evaluated through a forced dynamic finite element analysis conducted as a part of this investigation. The theoretical results based on experimentally obtained damping ratios indicate that the passive dampers are considerably more effective under member natural vibration than during forced vibration. Also, the maximum damping under forced vibration occurs at or near resonance.

  7. Putty-like bone fillers based on CaP ceramics or Biosilicate® combined with carboxymethylcellulose: Characterization, optimization, and evaluation.

    PubMed

    Gabbai-Armelin, Paulo R; Renno, Ana Cm; Crovace, Murilo C; Magri, Angela Mp; Zanotto, Edgar D; Peitl, Oscar; Leeuwenburgh, Sander Cg; Jansen, John A; van den Beucken, Jeroen Jjp

    2017-08-01

    Calcium phosphates and bioactive glass ceramics have been considered promising biomaterials for use in surgeries. However, their moldability should be further enhanced. We here thereby report the handling, physicochemical features, and morphological characteristics of formulations consisting of carboxymethylcellulose-glycerol and hydroxyapatite-tricalcium phosphate or Biosilicate® particles. We hypothesized that combining either material with carboxymethylcellulose-glycerol would improve handling properties, retaining their bioactivity. In addition to scanning electron microscopy, cohesion, mineralization, pH, and viscoelastic properties of the novel formulations, cell culture experiments were performed to evaluate the cytotoxicity and cell proliferation. Putty-like formulations were obtained with improved cohesion and moldability. Remarkably, mineralization in simulated body fluid of hydroxyapatite-tricalcium phosphate/carboxymethylcellulose-glycerol formulations was enhanced compared to pure hydroxyapatite-tricalcium phosphate. Cell experiments showed that all formulations were noncytotoxic and that HA-TCP60 and BGC50 extracts led to an increased cell proliferation. We conclude that combining carboxymethylcellulose-glycerol with either hydroxyapatite-tricalcium phosphate or Biosilicate® allows for the generation of moldable putties, improves handling properties, and retains the ceramic bioactivity.

  8. Evaluation of Surface Quality of Silicone Impression Materials after Disinfection with Ozone Water: An In vitro Study.

    PubMed

    Abinaya, K; Muthu Kumar, B; Ahila, S C

    2018-01-01

    To compare and evaluate the surface quality of silicone impression materials after ozone water disinfection. A total of 60 samples were prepared on a stainless steel die (American Dental Association specification no. 19 and International Standard of Organization - 4823). The samples were divided into four groups; each group contains 15 samples. Group A as control, Group B, C, and D disinfected with 2% glutaraldehyde, 5.25% sodium hypochlorite, and ozone water, respectively. The samples were made according to the manufacturer's instructions, and the samples were allowed to set in a thermostatically controlled water bath at 35°C ± 1°C and retrieved after 10 min. The surface qualities of the samples were measured in stereomicroscope with ×20 magnification. The data obtained were analyzed using Chi-square test, and the " P " value was calculated. The results showed that there were no differences in the surface quality among the Groups A, C, and D for addition silicone putty and light body and medium body impression materials than the Group B. This study concluded that ozone water disinfection showed least changes when compared to 5.25%sodium hypochloride and 2% glutaraldehyde disinfection for addition silicone putty , light body and medium body impression materials.

  9. Accuracy of Multiple Pour Cast from Various Elastomer Impression Methods

    PubMed Central

    Saad Toman, Majed; Ali Al-Shahrani, Abdullah; Ali Al-Qarni, Abdullah

    2016-01-01

    The accurate duplicate cast obtained from a single impression reduces the profession clinical time, patient inconvenience, and extra material cost. The stainless steel working cast model assembly consisting of two abutments and one pontic area was fabricated. Two sets of six each custom aluminum trays were fabricated, with five mm spacer and two mm spacer. The impression methods evaluated during the study were additional silicone putty reline (two steps), heavy-light body (one step), monophase (one step), and polyether (one step). Type IV gypsum casts were poured at the interval of one hour, 12 hours, 24 hours, and 48 hours. The resultant cast was measured with traveling microscope for the comparative dimensional accuracy. The data obtained were subjected to Analysis of Variance test at significance level <0.05. The die obtained from two-step putty reline impression techniques had the percentage of variation for the height −0.36 to −0.97%, while diameter was increased by 0.40–0.90%. The values for one-step heavy-light body impression dies, additional silicone monophase impressions, and polyether were −0.73 to −1.21%, −1.34%, and −1.46% for the height and 0.50–0.80%, 1.20%, and −1.30% for the width, respectively. PMID:28096815

  10. Experimental study on the use of spacer foils in two-step putty and wash impression procedures using silicone impression materials.

    PubMed

    Mann, Karsten; Davids, Andreas; Range, Ursula; Richter, Gert; Boening, Klaus; Reitemeier, Bernd

    2015-04-01

    The 2-step putty and wash impression technique is commonly used in fixed prosthodontics. However, cutting sluiceways to allow the light-body material to drain is time-consuming. A solution might be the use of a spacer foil. The purpose of this study was to evaluate the influence of spacer foil on the margin reproduction and dimensional accuracy of 2-step putty and wash impressions. Two methods of creating space for the wash material in a 2-step putty and wash impression were compared: the traditional cutout technique and a spacer foil. Eleven commercially available combinations of silicone impression materials were included in the study. The impressions and the cast production were carried out under standardized conditions. All casts were measured with a 3-dimensional (3D) coordinate measuring machine. Preparation margin reproduction and the diameters and spacing of the stone cast dies were measured (α=.05). The 2 methods showed significant differences (P<.05) in the reproduction of the preparation margins (complete reproduction cutout, 90% to 98%; foil, 74% to 91%). The use of a foil resulted in greater dimensional accuracy of the cast dies compared to the cutout technique. Cast dies from the cutout technique were significantly smaller than the metallic original cast (cutout median, 4.55 mm to 4.61 mm; foil median, 4.61 to 4.64). Spacing between the dies revealed only a few additional significant differences between the techniques. When spacer foils were used, dies were obtained that better corresponded to the original tooth. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  11. Quantification of various growth factors in different demineralized bone matrix preparations.

    PubMed

    Wildemann, B; Kadow-Romacker, A; Haas, N P; Schmidmaier, G

    2007-05-01

    Besides autografts, allografts, and synthetic materials, demineralized bone matrix (DBM) is used for bone defect filling and treatment of non-unions. Different DBM formulations are introduced in clinic since years. However, little is known about the presents and quantities of growth factors in DBM. Aim of the present study was the quantification of eight growth factors important for bone healing in three different "off the shelf" DBM formulations, which are already in human use: DBX putty, Grafton DBM putty, and AlloMatrix putty. All three DBM formulations are produced from human donor tissue but they differ in the substitutes added. From each of the three products 10 different lots were analyzed. Protein was extracted from the samples with Guanidine HCL/EDTA method and human ELISA kits were used for growth factor quantification. Differences between the three different products were seen in total protein contend and the absolute growth factor values but also a large variability between the different lots was found. The order of the growth factors, however, is almost comparable between the materials. In the three investigated materials FGF basic and BMP-4 were not detectable in any analyzed sample. BMP-2 revealed the highest concentration extractable from the samples with approximately 3.6 microg/g tissue without a significant difference between the three DBM formulations. In DBX putty significantly more TGF-beta1 and FGFa were measurable compared to the two other DBMs. IGF-I revealed the significantly highest value in the AlloMatrix and PDGF in Grafton. No differences were accessed for VEGF. Due to the differences in the growth factor concentration between the individual samples, independently from the product formulation, further analyzes are required to optimize the clinical outcome of the used demineralized bone matrix. Copyright 2006 Wiley Periodicals, Inc.

  12. Rheological and physical characteristics of crustal-scaled materials for centrifuge analogue modelling

    NASA Astrophysics Data System (ADS)

    Waffle, Lindsay; Godin, Laurent; Harris, Lyal B.; Kontopoulou, M.

    2016-05-01

    We characterize a set of analogue materials used for centrifuge analogue modelling simulating deformation at different levels in the crust simultaneously. Specifically, we improve the rheological characterization in the linear viscoelastic region of materials for the lower and middle crust, and cohesive synthetic sands without petroleum-binding agents for the upper crust. Viscoelastic materials used in centrifuge analogue modelling demonstrate complex dynamic behaviour, so viscosity alone is insufficient to determine if a material will be an effective analogue. Two series of experiments were conducted using an oscillating bi-conical plate rheometer to measure the storage and loss moduli and complex viscosities of several modelling clays and silicone putties. Tested materials exhibited viscoelastic and shear-thinning behaviour. The silicone putties and some modelling clays demonstrated viscous-dominant behaviour and reached Newtonian plateaus at strain rates < 0.5 × 10-2 s-1, while other modelling clays demonstrated elastic-dominant power-law relationships. Based on these results, the elastic-dominant modelling clay is recommended as an analogue for basement cratons. Inherently cohesive synthetic sands produce fine-detailed fault and fracture patterns, and developed thrust, strike-slip, and extensional faults in simple centrifuge test models. These synthetic sands are recommended as analogues for the brittle upper crust. These new results increase the accuracy of scaling analogue models to prototype. Additionally, with the characterization of three new materials, we propose a complete lithospheric profile of analogue materials for centrifuge modelling, allowing future studies to replicate a broader range of crustal deformation behaviours.

  13. A Comparison of Accuracy of Matrix Impression System with Putty Reline Technique and Multiple Mix Technique: An In Vitro Study.

    PubMed

    Kumar, M Praveen; Patil, Suneel G; Dheeraj, Bhandari; Reddy, Keshav; Goel, Dinker; Krishna, Gopi

    2015-06-01

    The difficulty in obtaining an acceptable impression increases exponentially as the number of abutments increases. Accuracy of the impression material and the use of a suitable impression technique are of utmost importance in the fabrication of a fixed partial denture. This study compared the accuracy of the matrix impression system with conventional putty reline and multiple mix technique for individual dies by comparing the inter-abutment distance in the casts obtained from the impressions. Three groups, 10 impressions each with three impression techniques (matrix impression system, putty reline technique and multiple mix technique) were made of a master die. Typodont teeth were embedded in a maxillary frasaco model base. The left first premolar was removed to create a three-unit fixed partial denture situation and the left canine and second premolar were prepared conservatively, and hatch marks were made on the abutment teeth. The final casts obtained from the impressions were examined under a profile projector and the inter-abutment distance was calculated for all the casts and compared. The results from this study showed that in the mesiodistal dimensions the percentage deviation from master model in Group I was 0.1 and 0.2, in Group II was 0.9 and 0.3, and Group III was 1.6 and 1.5, respectively. In the labio-palatal dimensions the percentage deviation from master model in Group I was 0.01 and 0.4, Group II was 1.9 and 1.3, and Group III was 2.2 and 2.0, respectively. In the cervico-incisal dimensions the percentage deviation from the master model in Group I was 1.1 and 0.2, Group II was 3.9 and 1.7, and Group III was 1.9 and 3.0, respectively. In the inter-abutment dimension of dies, percentage deviation from master model in Group I was 0.1, Group II was 0.6, and Group III was 1.0. The matrix impression system showed more accuracy of reproduction for individual dies when compared with putty reline technique and multiple mix technique in all the three directions, as well as the inter-abutment distance.

  14. Comparison of posterolateral lumbar fusion rates of Grafton Putty and OP-1 Putty in an athymic rat model.

    PubMed

    Bomback, David A; Grauer, Jonathan N; Lugo, Roberto; Troiano, Nancy; Patel, Tushar Ch; Friedlaender, Gary E

    2004-08-01

    Posterolateral lumbar spine fusions in athymic rats. To compare spine fusion rates of two different osteoinductive products. Many osteoinductive bone graft alternatives are available. Grafton (a demineralized bone matrix [DBM]) and Osteogenic Protein-1 (OP-1, an individual recombinant bone morphogenetic protein) are two such alternatives. The relative efficacy of products from these two classes has not been previously studied. The athymic rat spine fusion model has been validated and demonstrated useful to minimize inflammatory responses to xenogeneic or differentially expressed proteins such as those presented by DBMs of human etiology. Single-level intertransverse process fusions were performed in 60 athymic nude rats with 2 cc/kg of Grafton or OP-1 Putty. Half of each study group was killed at 3 weeks and half at 6 weeks. Fusion masses were assessed by radiography, manual palpation, and histology. At 3 weeks, manual palpation revealed a 13% fusion rate with Grafton and a 100% fusion rate with OP-1 (P = 0.0001). At 6 weeks, manual palpation revealed a 39% fusion rate of with Grafton and a 100% fusion rate with OP-1 (P = 0.0007). Similar fusion rates were found by histology at 3 and 6 weeks. Of note, one or two adjacent levels were fused in all of the OP-1 animals and none of the Grafton animals. Significant differences between the ability of Grafton and OP-1 to induce bone formation in an athymic rat posterolateral lumbar spine fusion model were found.

  15. 40 CFR 63.4681 - Am I subject to this subpart?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... application of clay slurry, titanium dioxide, or asphalt coatings to fiberboard. (v) Painting of company logo...) Synthetic patches, wood patches, and wood putty applied to plywood. (ix) Application of concrete forming and...

  16. What Is a Colloid?

    ERIC Educational Resources Information Center

    Lamb, William G.

    1985-01-01

    Describes the properties of colloids, listing those commonly encountered (such as whipped cream, mayonnaise, and fog). Also presents several experiments using colloids and discusses "Silly Putty," a colloid with viscoelastic properties whose counterintuitive properties result from its mixture of polymers. (DH)

  17. 77 FR 20356 - Foreign-Trade Zone 277-Western Maricopa County, AZ; Application for Manufacturing Authority...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-04

    ... facility is used for the manufacture of 275 and 290 watt solar panels for industrial use. Components and... boxes, silicone sealant, putty/caulking compounds, plastic sheets, glass, tin-coated copper strips...

  18. Dimensional Accuracy of Hydrophilic and Hydrophobic VPS Impression Materials Using Different Impression Techniques - An Invitro Study

    PubMed Central

    Pilla, Ajai; Pathipaka, Suman

    2016-01-01

    Introduction The dimensional stability of the impression material could have an influence on the accuracy of the final restoration. Vinyl Polysiloxane Impression materials (VPS) are most frequently used as the impression material in fixed prosthodontics. As VPS is hydrophobic when it is poured with gypsum products, manufacturers added intrinsic surfactants and marketed as hydrophilic VPS. These hydrophilic VPS have shown increased wettability with gypsum slurries. VPS are available in different viscosities ranging from very low to very high for usage under different impression techniques. Aim To compare the dimensional accuracy of hydrophilic VPS and hydrophobic VPS using monophase, one step and two step putty wash impression techniques. Materials and Methods To test the dimensional accuracy of the impression materials a stainless steel die was fabricated as prescribed by ADA specification no. 19 for elastomeric impression materials. A total of 60 impressions were made. The materials were divided into two groups, Group1 hydrophilic VPS (Aquasil) and Group 2 hydrophobic VPS (Variotime). These were further divided into three subgroups A, B, C for monophase, one-step and two-step putty wash technique with 10 samples in each subgroup. The dimensional accuracy of the impressions was evaluated after 24 hours using vertical profile projector with lens magnification range of 20X-125X illumination. The study was analyzed through one-way ANOVA, post-hoc Tukey HSD test and unpaired t-test for mean comparison between groups. Results Results showed that the three different impression techniques (monophase, 1-step, 2-step putty wash techniques) did cause significant change in dimensional accuracy between hydrophilic VPS and hydrophobic VPS impression materials. One-way ANOVA disclosed, mean dimensional change and SD for hydrophilic VPS varied between 0.56% and 0.16%, which were low, suggesting hydrophilic VPS was satisfactory with all three impression techniques. However, mean dimensional change and SD for hydrophobic VPS were much higher with monophase, mere increase for 1-step and 2-step, than the standard steel die (p<0.05). Unpaired t-test displayed that hydrophilic VPS judged satisfactory compared to hydrophobic VPS among 1-step and 2-step impression technique. Conclusion Within the limitations of this study, it can be concluded that hydrophilic Vinyl polysiloxane was more dimensionally accurate than hydrophobic Vinyl polysiloxane using monophase, one step and two step putty wash impression techniques under moist conditions. PMID:27042587

  19. A Comparison of Accuracy of Matrix Impression System with Putty Reline Technique and Multiple Mix Technique: An In Vitro Study

    PubMed Central

    Kumar, M Praveen; Patil, Suneel G; Dheeraj, Bhandari; Reddy, Keshav; Goel, Dinker; Krishna, Gopi

    2015-01-01

    Background: The difficulty in obtaining an acceptable impression increases exponentially as the number of abutments increases. Accuracy of the impression material and the use of a suitable impression technique are of utmost importance in the fabrication of a fixed partial denture. This study compared the accuracy of the matrix impression system with conventional putty reline and multiple mix technique for individual dies by comparing the inter-abutment distance in the casts obtained from the impressions. Materials and Methods: Three groups, 10 impressions each with three impression techniques (matrix impression system, putty reline technique and multiple mix technique) were made of a master die. Typodont teeth were embedded in a maxillary frasaco model base. The left first premolar was removed to create a three-unit fixed partial denture situation and the left canine and second premolar were prepared conservatively, and hatch marks were made on the abutment teeth. The final casts obtained from the impressions were examined under a profile projector and the inter-abutment distance was calculated for all the casts and compared. Results: The results from this study showed that in the mesiodistal dimensions the percentage deviation from master model in Group I was 0.1 and 0.2, in Group II was 0.9 and 0.3, and Group III was 1.6 and 1.5, respectively. In the labio-palatal dimensions the percentage deviation from master model in Group I was 0.01 and 0.4, Group II was 1.9 and 1.3, and Group III was 2.2 and 2.0, respectively. In the cervico-incisal dimensions the percentage deviation from the master model in Group I was 1.1 and 0.2, Group II was 3.9 and 1.7, and Group III was 1.9 and 3.0, respectively. In the inter-abutment dimension of dies, percentage deviation from master model in Group I was 0.1, Group II was 0.6, and Group III was 1.0. Conclusion: The matrix impression system showed more accuracy of reproduction for individual dies when compared with putty reline technique and multiple mix technique in all the three directions, as well as the inter-abutment distance. PMID:26124599

  20. Physics Notes.

    ERIC Educational Resources Information Center

    School Science Review, 1980

    1980-01-01

    Outlines a variety of laboratory procedures, discussions, and demonstrations including a no-solder circuit board, damped to maintained oscillations with L-C circuits, polaroid strobe photos, resistive putty, soldering and circuit checking exercise, electromagnetic radiation, square pulses in C-R circuits, and testing an oscillating system. (GS)

  1. Dimensional stability of two impression materials after a 6-month storage period.

    PubMed

    Martins, Francisco; Branco, Patrícia; Reis, José; Barbero Navarro, Ignacio; Maurício, Paulo

    2017-01-01

    Objective: Oral rehabilitation success is enhanced by an accurate and reproducible final impression. The purpose of this study is to evaluate the dimensional changes of a polyether and addition silicone subjected to disinfection and/or sterilization after a long storage period. Material and methods: Ninety samples were obtained from polyether Impregum TM Penta TM (3M ESPE TM , Seefeld, Germany) and 90 of addition silicone Imprint TM 4 Penta TM Putty (3M ESPE TM , Seefeld, Germany) according to ISO 4823:2000. The samples of each material were split to form three groups with 30 samples each: a control group, a hypochlorite group (disinfection) and an autoclave group (sterilization). Samples were stored in the Portuguese Institute for Quality for six months at 23 °C. Samples were measured by laser interferometry, according to the Michelson technique before calculating dimensional stability according ISO 4823:2000. A statistical analysis via a three-way mixed ANOVA was performed. Results: Significant shrinkage of Impregum TM Penta TM was 0.77 ± 0.17% in the control group, 0.42 ± 0.19% in the hypochlorite group and 0.52 ± 0.28% in the autoclave group. For Imprint TM 4 Penta TM Putty, the control group had a shrinkage of 0.42 ± 0.12%, the hypochlorite group 0.36 ± 0.09% and the autoclave group 0.59 ± 0.13%. Conclusions: The long-term storage of samples subjected to disinfection with 5.25% hypochlorite or autoclave sterilization can be used in a clinical setting as the dimensional changes are below the maximum permitted by the ISO 4823:2000, since there are no clinically significant changes in the dimension of the samples during the storage period.

  2. Crystallization and Colloidal Stabilization of Ca(OH)2 in the Presence of Nopal Juice (Opuntia ficus indica): Implications in Architectural Heritage Conservation.

    PubMed

    Rodriguez-Navarro, Carlos; Ruiz-Agudo, Encarnacion; Burgos-Cara, Alejandro; Elert, Kerstin; Hansen, Eric F

    2017-10-17

    Hydrated lime (Ca(OH) 2 ) is a vernacular art and building material produced following slaking of CaO in water. If excess water is used, a slurry, called lime putty, forms, which has been the preferred craftsman selection for formulating lime mortars since Roman times. A variety of natural additives were traditionally added to the lime putty to improve its quality. The mucilaginous juice extracted from nopal cladodes has been and still is used as additive incorporated in the slaking water for formulation of lime mortars and plasters, both in ancient Mesoamerica and in the USA Southwest. Little is known on the ultimate effects of this additive on the crystallization and microstructure of hydrated lime. Here, we show that significant changes in habit and size of portlandite crystals occur following slaking in the presence of nopal juice as well as compositionally similar citrus pectin. Both additives contain polysaccharides made up of galacturonic acid and neutral sugar residues. The carboxyl (and hydroxyl) functional groups present in these residues and in their alkaline degradation byproducts, which are deprotonated at the high pH (12.4) produced during lime slaking, strongly interact with newly formed Ca(OH) 2 crystals acting in two ways: (a) as nucleation inhibitors, promoting the formation of nanosized crystals, and (b) as habit modifiers, favoring the development of planar habit following their adsorption onto positively charged (0001) Ca(OH) 2 faces. Adsorption of polysaccharides on Ca(OH) 2 crystals prevents the development of large particles, resulting in a very reactive, nanosized portlandite slurry. It also promotes steric stabilization, which limits aggregation, thus enhancing the colloidal nature of the lime putty. Overall, these effects are very favorable for the preparation of highly plastic lime mortars with enhanced properties.

  3. Microcomputed tomographic and histologic analysis of anorganic bone matrix coupled with cell-binding peptide suspended in sodium hyaluronate carrier after sinus augmentation: a clinical study.

    PubMed

    Emam, Hany; Beheiri, Galal; Elsalanty, Mohammed; Sharawy, Mohamed

    2011-01-01

    Anorganic bovine hydroxyapatite matrix (ABM), when coupled with synthetic cell-binding peptide (P15), mimics the cell-binding region of type 1 collagen and is commercially available suspended in a sodium hyaluronate carrier. The aim of the present study, therefore, was to test the efficacy of ABM/P-15 Putty (DENTSPLY Friadent CeraMed) as a sole graft material for sinus augmentation in patients with severely resorbed posterior maxillae. Sinus augmentation was performed in 10 patients using ABM/P-15 Putty and two provisional dental implants (3.0 mm in diameter). The graft and implants were placed simultaneously with the aid of a surgical stent. After 8 or 16 weeks, the implants were removed using a 4.25-mm trephine bur; this was followed by immediate placement of wider-diameter (5.5-mm) implants. All 20 implants were scanned by microcomputed tomography to determine bone mineral density (BMD), percent bone volume (PBV), and percent bone contact (PBC). There was a significant increase in the BMD of bone around the implants at 8 weeks and 16 weeks compared to native residual (control) bone. There was no significant difference in PBV or PBC between 8 weeks and 16 weeks. The average increase in bone height at 16 weeks was 9.63 ± 1 mm. Microcomputed tomographic images and histologic sections showed dense graft particles surrounded by vital trabecular bone. BMD increases as early as 8 weeks and does not show an additional increase after 16 weeks. PepGen P-15 Putty was found to be a promising osteoconductive graft for sinus augmentation, supporting immediate placement of implants.

  4. Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

    PubMed Central

    Pastoret, Marie-Hélène; Bühler, Julia; Weiger, Roland

    2017-01-01

    PURPOSE To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (± SD). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS Dimensional changes compared to reference values varied between -74.01 and 32.57 µm (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth. PMID:28874996

  5. A direct method for fabricating tongue-shielding stent.

    PubMed

    Wang, R R; Olmsted, L W

    1995-08-01

    During oral cancer radiotherapy, a tongue-shielding radiation stent guides the patient's upper and lower jaws to a repeatable position, attenuates radiation doses, and protects the tongue and structures adjacent to the irradiated field. Conventionally, a tongue-shielding radiation stent is made of heat-cured polymethyl methacrylate resin in which a low-melting Pb-Bi-Sn alloy is embedded as a shielding layer. Its use involves multiple and lengthy clinical and laboratory procedures. An improved polyvinyl siloxane-metal composite shielding system for radioprotection has recently been developed. This two-component, base and catalyst, putty material offers a shielding effect similar to that of the conventional shielding alloys. Its major advantages are that it is simple to use, requires only one clinical appointment, and affords efficient collaboration between dental and medical teams during cancer treatment. This article describes a simplified direct method of fabricating a tongue-shielding stent with the use of a new polyvinylsiloxane-metal composite in conjunction with impression putty material.

  6. Evaluation of amorphous magnesium phosphate (AMP) based non-exothermic orthopedic cements.

    PubMed

    Babaie, Elham; Lin, Boren; Goel, Vijay K; Bhaduri, Sarit B

    2016-10-07

    This paper reports for the first time the development of a biodegradable, non-exothermic, self-setting orthopedic cement composition based on amorphous magnesium phosphate (AMP). The occurrence of undesirable exothermic reactions was avoided through using AMP as the solid precursor. The phenomenon of self-setting with optimum rheology is achieved by incorporating a water soluble biocompatible/biodegradable polymer, polyvinyl alcohol (PVA). Additionally, PVA enables a controlled growth of the final phase via a biomimetic process. The AMP powder was synthesized using a precipitation method. The powder, when in contact with the aqueous PVA solution, forms a putty resulting in a nanocrystalline magnesium phosphate phase of cattiite. The as-prepared cement compositions were evaluated for setting times, exothermicity, compressive strength, biodegradation, and microstructural features before and after soaking in SBF, and in vitro cytocompatibility. Since cattiite is relatively unexplored in the literature, a first time evaluation reveals that it is cytocompatible, just like the other phases in the MgO-P 2 O 5 (Mg-P) system. The cement composition prepared with 15% PVA in an aqueous medium achieved clinically relevant setting times, mechanical properties, and biodegradation. Simulated body fluid (SBF) soaking resulted in coating of bobierrite onto the cement particle surfaces.

  7. How to Learn and Have Fun with Poly(Vinyl Alcohol) and White Glue.

    ERIC Educational Resources Information Center

    de Zea Bermudez, V.; Passos de Almeida, P.; Feria Seita, J.

    1998-01-01

    Presents a classroom guide for a simple theoretical approach to the study of certain fluids. Discusses background information, followed by experimental procedures for the preparation of two popular viscoelastic materials ("Slime" and "Silly Putty") that exhibit unusual flow properties. Also lists student discussion questions…

  8. Symposium: Editing a Norton Anthology

    ERIC Educational Resources Information Center

    Finke, Laurie; Johnson, Barbara; Leitch, Vincent B.; McGowan, John; Williams, Jeffrey J.

    2003-01-01

    Literature anthologies are part of the furniture of English departments. Like the putty or gunmetal-gray file cabinet that one might have gotten new or used, they are not a showpiece of academic decor, but it would be hard to imagine work spaces without them. Indeed, they are omnipresent, amassed on the shelves of campus bookstores, weighing down…

  9. Desensitization of metastable intermolecular composites

    DOEpatents

    Busse, James R [South Fork, CO; Dye, Robert C [Los Alamos, NM; Foley, Timothy J [Los Alamos, NM; Higa, Kelvin T [Ridgecrest, CA; Jorgensen, Betty S [Jemez Springs, NM; Sanders, Victor E [White Rock, NM; Son, Steven F [Los Alamos, NM

    2011-04-26

    A method to substantially desensitize a metastable intermolecular composite material to electrostatic discharge and friction comprising mixing the composite material with an organic diluent and removing enough organic diluent from the mixture to form a mixture with a substantially putty-like consistency, as well as a concomitant method of recovering the metastable intermolecular composite material.

  10. Desensitization and recovery of metastable intermolecular composites

    DOEpatents

    Busse, James R [South Fork, CO; Dye, Robert C [Los Alamos, NM; Foley, Timothy J [Los Alamos, NM; Higa, Kelvin T [Ridgecrest, CA; Jorgensen, Betty S [Jemez Springs, NM; Sanders, Victor E [White Rock, NM; Son, Steven F [Los Alamos, NM

    2010-09-07

    A method to substantially desensitize a metastable intermolecular composite material to electrostatic discharge and friction comprising mixing the composite material with an organic diluent and removing enough organic diluent from the mixture to form a mixture with a substantially putty-like consistency, as well as a concomitant method of recovering the metastable intermolecular composite material.

  11. Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection.

    PubMed

    Kamble, Suresh S; Khandeparker, Rakshit Vijay; Somasundaram, P; Raghav, Shweta; Babaji, Rashmi P; Varghese, T Joju

    2015-09-01

    Impression materials during impression procedure often get infected with various infectious diseases. Hence, disinfection of impression materials with various disinfectants is advised to protect the dental team. Disinfection can alter the dimensional accuracy of impression materials. The present study was aimed to evaluate the dimensional accuracy of elastomeric impression materials when treated with different disinfectants; autoclave, chemical, and microwave method. The impression materials used for the study were, dentsply aquasil (addition silicone polyvinylsiloxane syringe and putty), zetaplus (condensation silicone putty and light body), and impregum penta soft (polyether). All impressions were made according to manufacturer's instructions. Dimensional changes were measured before and after different disinfection procedures. Dentsply aquasil showed smallest dimensional change (-0.0046%) and impregum penta soft highest linear dimensional changes (-0.026%). All the tested elastomeric impression materials showed some degree of dimensional changes. The present study showed that all the disinfection procedures produce minor dimensional changes of impression material. However, it was within American Dental Association specification. Hence, steam autoclaving and microwave method can be used as an alternative method to chemical sterilization as an effective method.

  12. Single Stage Silicone Border Molded Closed Mouth Impression Technique-Part II.

    PubMed

    Solomon, E G R

    2011-09-01

    Functioning of a complete denture depends to a great extent on the impression technique. Several impression techniques have been described in the literature since the turn of this century when Greene [Clinical courses in dental prothesis, 1916] brothers introduced the first scientific system of recording dental impression. Advocates of each technique have their own claim of superiority over the other. The introduction of elastomeric impression materials [Skinner and Cooper, J Am Dent Assoc 51:523-536, 1955] has made possible new techniques of recording impression for complete denture construction. These rubber like materials are of two types; one has a polysulfide base and is popularily known as polysulfide rubber (Thiokol and Mercaptan). The other variety has a silicone base known as silicone rubber or silicone elastomer. Silicone elastomers are available in four different consistencies; a thin easy flowing light bodied material,a creamy medium bodied material, a highly viscous heavy bodied material and a kneadable putty material. This paper describes an active closed mouth impression technique with one stage border molding using putty silicone material as a substitute for low fusing compound.

  13. Comparison of applying particulate demineralized bone matrix (DBM), putty DBM and open flap debridement in periodontal horizontal bone defects. A 12-month longitudinal, multi-centre, triple-blind, split-mouth, randomized, controlled clinical study. Part 2 - evaluation of the interdental soft tissue.

    PubMed

    Kaya, Y; Yalim, M; Bahçecitapar, M; Baloş, K

    2009-07-01

    To date, there have been many studies clinically evaluating periodontal regenerative procedures by the help of routinely used hard and soft tissue parameters; however, these parameters are not capable of assessing interdental soft tissue located above the regenerative periodontal surgery area. The purpose of this study was to assess interproximal soft tissue changes following application of (i) particulate form demineralized bone matrix (DBM), (ii) putty form DBM and (ii) open flap debridement (OFD, control), using modified curtain technique in the treatment of interproximal suprabony (horizontal) defects located in anterior maxillary region, as previously reported. Twenty-five chronic periodontitis patients with 125 interproximal surgery sites (radiologically >or=4 mm horizontal bone defect) were also participate in this second stage of the triple-blind, split mouth, randomized, controlled clinical trial. Surgery sites were assessed by (i) plaque index (PI), (ii) gingival index (GI), (iii) the presence of interdental soft tissue clefts or craters and (iv) the loss of interdental papilla height by using papilla presence index (PPI), during the healing period. At the baseline and 3, 6, 9 and 12 months after the operations, these measurements were repeated. In all groups, there is a significant increase in the prevalence of soft tissue cleft and crater formation (P < 0.01), with increase in PI and GI scores at interdental soft tissue defect areas (P < 0.001), 3 months after the operations. There was also an increase in PPI scores after the operations in all treatment groups (P < 0.01). Three procedures affected the interproximal soft tissues similarly. There was no significant difference among groups in terms of all parameters (P > 0.05). Particulate DBM, putty DBM and OFD demostrated similar interproximal soft tissue changes especially increasing interproximal PI and GI scores in 3 months follow-up.

  14. Laboratory Activity: Specific Heat by Change in Internal Energy of Silly Putty

    ERIC Educational Resources Information Center

    Koser, John

    2011-01-01

    Students in introductory physics courses often don't study thermodynamics or thermodynamic events. If any thermal physics is taught in introductory courses (e.g., Physics 101 for Liberal Arts Majors), it usually involves the concepts of specific heat and various temperature scales. Seldom are the first and second laws of thermodynamics taught in…

  15. Elastic Properties of Plasticine, Silly Putty, and Tennis Strings

    ERIC Educational Resources Information Center

    Cross, Rod

    2012-01-01

    How would a physicist describe the elastic properties of an apple or a banana? Physics students and teachers are familiar with the elastic properties of metal springs, but are likely to be less familiar with the elastic properties of other common materials. The behavior of a metal spring is commonly examined in the laboratory by adding masses to…

  16. Plastic Clamp Retains Clevis Pin

    NASA Technical Reports Server (NTRS)

    Cortes, R. G.

    1983-01-01

    Plastic clamp requires no special installation or removal tools. Clamp slips easily over end of pin. Once engaged in groove, holds pin securely. Installed and removed easily without special tools - screwdriver or putty knife adequate for prying out of groove. Used to retain bearings, rollers pulleys, other parts that rotate. Applications include slowly and intermittently rotating parts in appliances.

  17. Flexible Interior-Impression-Molding Tray

    NASA Technical Reports Server (NTRS)

    Anders, Jeffrey E.

    1991-01-01

    Device used inside combustion chamber of complicated shape for nondestructive evaluation of qualities of welds, including such features as offset, warping, misalignment of parts, and dropthrough. Includes flexible polypropylene tray trimmed to fit desired interior surface contour. Two neodymium boron magnets and inflatable bladder attached to tray. Tray and putty inserted in cavity to make mold of interior surface.

  18. University of Maryland MRSEC - News

    Science.gov Websites

    . Come by to make silly putty polymers, UV-sensitive color-changing bead bracelets, or try out the UV -sensitive color-changing nail polish. We hope to see you there! [04/18/13] Former MRSEC REU Student PowerPoint, you may download the free PowerPoint Viewer to view the slides. [07/06/12] MRSEC Ph.D. student

  19. Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection

    PubMed Central

    Kamble, Suresh S; Khandeparker, Rakshit Vijay; Somasundaram, P; Raghav, Shweta; Babaji, Rashmi P; Varghese, T Joju

    2015-01-01

    Background: Impression materials during impression procedure often get infected with various infectious diseases. Hence, disinfection of impression materials with various disinfectants is advised to protect the dental team. Disinfection can alter the dimensional accuracy of impression materials. The present study was aimed to evaluate the dimensional accuracy of elastomeric impression materials when treated with different disinfectants; autoclave, chemical, and microwave method. Materials and Methods: The impression materials used for the study were, dentsply aquasil (addition silicone polyvinylsiloxane syringe and putty), zetaplus (condensation silicone putty and light body), and impregum penta soft (polyether). All impressions were made according to manufacturer’s instructions. Dimensional changes were measured before and after different disinfection procedures. Result: Dentsply aquasil showed smallest dimensional change (−0.0046%) and impregum penta soft highest linear dimensional changes (−0.026%). All the tested elastomeric impression materials showed some degree of dimensional changes. Conclusion: The present study showed that all the disinfection procedures produce minor dimensional changes of impression material. However, it was within American Dental Association specification. Hence, steam autoclaving and microwave method can be used as an alternative method to chemical sterilization as an effective method. PMID:26435611

  20. Cutting Symmetrical Recesses In Soft Ceramic Tiles

    NASA Technical Reports Server (NTRS)

    Nesotas, Tony C.; Tyler, Brent

    1989-01-01

    Simple tool cuts hemispherical recesses in soft ceramic tiles. Designed to expose wires of thermocouples embedded in tiles without damaging leads. Creates neat, precise holes around wires. End mill includes axial hole to accommodate thermocouple wires embedded in material to be cut. Wires pass into hole without being bent or broken. Dimensions in inches. Used in place of such tools as dental picks, tweezers, spatulas, and putty knives.

  1. Polymer Claw: Instant Underwater Adhesive

    DTIC Science & Technology

    2012-03-23

    technology is the use of pressure sensitive microcapsules , which release reactive amine crosslinkers into an adhesive putty when pressed against the...PROIECT GOALS AND OBIECTIVES 2 2 KEY ACCOMPLISHMENTS 2 3.1 KICKOFF MEETING 3 3.2 AMINE MICROENCAPSULATION 3 3.3 CAUSTIC CLEANING AGENT 5 3.4...caustic, and the abrasive brush. We successfully synthesized amine-filled microcapsules and a dry mixture of caustic ingredients that only activate when

  2. Practical aspects of the use of phosphate binding materials in refractory mixtures, mortars and putties

    NASA Technical Reports Server (NTRS)

    Soltysik, B.; Pawelek, A.; Witkowska, E.

    1983-01-01

    Phosphate binders, particularly acidic phosphates of Al and Cr, are used for binding Al silicate refractories used for lining of burners, SiC refractories, and refractory mortars. The binders have apparent d. 2.13-2.18 g/cu cm, porosity 21.4-23.8%, compressive strength 223 71 kg/ sq cm, total shrinkage 0.2-0.8%, and refractoriness 1240 deg.

  3. Polymer Claw: Instant Underwater Adhesive

    DTIC Science & Technology

    2012-08-27

    technology is the use of pressure sensitive microcapsules , which release reactive amine crosslinkers into an adhesive putty when pressed against the surface...CLEANING AGENT RHEOLOGY 3 3.3 PRESSURE-ACTIVATED ADHESIVE 5 3.3.1 PROCESSING IMPROVEMENTS 5 3.3.2 MICROCAPSULE DIAMETER 5 3.3.3 MICROCAPSULE /RESIN...to attain a reasonable shelf life (- l wk.). The microcapsule diameter has been halved in order to improve mixing in the pressure-activated

  4. In vitro evaluation of resonance frequency analysis values to different implant contact ratio and stiffness of surrounding material.

    PubMed

    Kwak, Mu-Seung; Kim, Seok-Gyu

    2013-11-01

    The present study was aimed to evaluate the influence of implant contact ratio and stiffness of implant-surrounding materials on the resonance frequency analysis (RFA) values. Seventy resin blocks that had the different amounts (100, 50, 30, 15%) of resin-implant contact (RIC) were fabricated. Ten silicone putty blocks with 100% silicone-implant contact were also made. The implants with Ø5.0 mm × 13.0 mm were placed on eighty specimen blocks. The RFA value was measured on the transducer that was connected to each implant by Osstell Mentor. Kruskal-Wallis and Scheffe's tests (α=.05) were done for statistical analysis. The control resin group with 100% RIC had the highest RFA value of 83.9, which was significantly different only from the resin group with 15% RIC among the resin groups. The silicone putty group with 100% contact had the lowest RFA value of 36.6 and showed statistically significant differences from the resin groups. Within the limitations of this in vitro study, there was no significant difference in the RFA values among the resin groups with different RIC's except when the RIC difference was more than 85%. A significant increase in the RFA value was observed related to the increase in stiffness of material around implant.

  5. Design and implementation of modular home security system with short messaging system

    NASA Astrophysics Data System (ADS)

    Budijono, Santoso; Andrianto, Jeffri; Axis Novradin Noor, Muhammad

    2014-03-01

    Today we are living in 21st century where crime become increasing and everyone wants to secure they asset at their home. In that situation user must have system with advance technology so person do not worry when getting away from his home. It is therefore the purpose of this design to provide home security device, which send fast information to user GSM (Global System for Mobile) mobile device using SMS (Short Messaging System) and also activate - deactivate system by SMS. The Modular design of this Home Security System make expandable their capability by add more sensors on that system. Hardware of this system has been designed using microcontroller AT Mega 328, PIR (Passive Infra Red) motion sensor as the primary sensor for motion detection, camera for capturing images, GSM module for sending and receiving SMS and buzzer for alarm. For software this system using Arduino IDE for Arduino and Putty for testing connection programming in GSM module. This Home Security System can monitor home area that surrounding by PIR sensor and sending SMS, save images capture by camera, and make people panic by turn on the buzzer when trespassing surrounding area that detected by PIR sensor. The Modular Home Security System has been tested and succeed detect human movement.

  6. Effect of a Particulate and a Putty-Like Tricalcium Phosphate-Based Bone-grafting Material on Bone Formation, Volume Stability and Osteogenic Marker Expression after Bilateral Sinus Floor Augmentation in Humans

    PubMed Central

    Knabe, Christine; Adel Khattab, Doaa; Kluk, Esther; Struck, Rainer; Stiller, Michael

    2017-01-01

    This study examines the effect of a hyaluronic acid (HyAc) containing tricalcium phosphate putty scaffold material (TCP-P) and of a particulate tricalcium phosphate (TCP-G) graft on bone formation, volume stability and osteogenic marker expression in biopsies sampled 6 months after bilateral sinus floor augmentation (SFA) in 7 patients applying a split-mouth design. 10% autogenous bone chips were added to the grafting material during surgery. The grain size of the TCP granules was 700 to 1400 µm for TCP-G and 125 to 250 µm and 500 to 700 µm (ratio 1:1) for TCP-P. Biopsies were processed for immunohistochemical analysis of resin-embedded sections. Sections were stained for collagen type I (Col I), alkaline phosphatase (ALP), osteocalcin (OC) and bone sialoprotein (BSP). Furthermore, the bone area and biomaterial area fraction were determined histomorphometrically. Cone-beam CT data recorded after SFA and 6 months later were used for calculating the graft volume at these two time points. TCP-P displayed more advantageous surgical handling properties and a significantly greater bone area fraction and smaller biomaterial area fraction. This was accompanied by significantly greater expression of Col I and BSP and in osteoblasts and osteoid and a less pronounced reduction in grafting volume with TCP-P. SFA using both types of materials resulted in formation of sufficient bone volume for facilitating stable dental implant placement with all dental implants having been in function without any complications for 6 years. Since TCP-P displayed superior surgical handling properties and greater bone formation than TCP-G, without the HyAc hydrogel matrix having any adverse effect on bone formation or graft volume stability, TCP-P can be regarded as excellent grafting material for SFA in a clinical setting. The greater bone formation observed with TCP-P may be related to the difference in grain size of the TCP granules and/or the addition of the HyAc. PMID:28758916

  7. The Effect of Slab Holes on the Surrounding Mantle Flow Field and the Surface from a Multi-Disciplinary Approach

    NASA Astrophysics Data System (ADS)

    Portner, D. E.; Kiraly, A.; Makushkina, A.; Parks, B. H.; Ghosh, T.; Haynie, K. L.; Metcalf, K.; Manga, M.; O'Farrell, K. A.; Moresi, L. N.; Jadamec, M. A.; Stern, R. J.

    2017-12-01

    Large-scale detachment of subducting slabs can have a significant geologic footprint by altering the slab-driven mantle flow field as hot subslab mantle can flow upward through the newly developed opening in the slab. The resulting increase in heat and vertical motion in the mantle wedge may contribute to volcanism and broad surface uplift. Recent geodynamic modeling results show that smaller tears and holes are similarly likely to form in many settings, such as where oceanic ridges or continental fragments subduct. High-resolution seismic tomography models are imaging an increasing number of these gaps and tears ranging in size from tens to hundreds of km in size, many of which occur proximal to alkali volcanism. Here we investigate the role of such gaps on the subduction-induced mantle flow field and related surface response. In particular, we address the relationships between slab hole size, depth, and distance from the slab edge and the magnitude of dynamic response of the mantle using analog experiments and numerical simulations. In the laboratory models, the subduction system is simplified to a two-layered Newtonian viscous sheet model. Our setup consists of a tank filled with glucose syrup and a plate made from silicon putty to model the upper mantle and subducting lithosphere, respectively. In each experiment, we pre-cut a rectangular hole with variable width into the silicon putty plate. Additionally, we perform a series of complementary numerical models using the Underworld geophysical modeling code to calculate the more detailed instantaneous mantle flow perturbation induced by the slab hole. Together, these results imply a strong effect of hole size on mantle flow. Similarly, the depth of the slab hole influences near-surface flow, with significant surface flow alteration when the hole is near the trench and diminishing surface deformation as the hole is dragged deeper into the mantle. The inferred consequence of the dependence of vertical mantle flux on slab hole position and size is that the induced surface response can vary based on slab hole parameters.

  8. Spectrophotometric Analysis of Coronal Tooth Discoloration Induced by Various Bioceramic Cements and Other Endodontic Materials.

    PubMed

    Kohli, Meetu R; Yamaguchi, Maimi; Setzer, Frank C; Karabucak, Bekir

    2015-11-01

    Coronal tooth discoloration induced by various endodontic materials was evaluated in vitro. Eighty extracted human maxillary anterior teeth were accessed, instrumented, and sectioned to standardized root lengths of 10 mm below the cementoenamel junction. Pulp chambers were cleaned chemomechanically to ensure complete tissue removal. Specimens were filled with experimental materials in 8 random groups: RRM, EndoSequence RRM putty (Brasseler, Savannah, GA); RRMF, EndoSequence RRM fast set paste (Brasseler); BD, Biodentine (Septodont, Saint-Maur-des-Fossés, France); WMTA, white MTA (Dentsply, York, PA), GMTA, gray MTA (Dentsply); AH+, AH Plus sealer (Dentsply); TAP, triple antibiotic paste (metronidazole, ciprofloxacin, and minocycline); and NF, no filling (negative control group). After incubation in 100% humidity at 37°C, color changes were evaluated with a spectrophotometer (Ocean Optics, Dunedin, FL) on days 0, 7, 30, 60, and 180 after material placement (T0-T180). Data were transformed into Commission International de I'Eclairage's L*a*b color values, and corresponding ΔE values were calculated. Two-way analysis of variance and the Bonferroni method were performed. Visual discoloration was observed in all specimens in the GMTA, WMTA, and TAP groups at T7, increasing with time. The ΔE value between the initial color at T0 and at T7, T30, T60, and T180 was significantly different for GMTA, WMTA, and TAP (P < .001). ΔE values for the BD, RRM, RRMF, AH+, and NF groups were not statistically significantly different between T0 and T7, T30, T60, and T180, respectively, except for 3 samples below the human perceptible threshold. Values of L* dropped significantly from T0 to T180 in the TAP, GMTA, and WMTA groups. Significant coronal tooth discoloration was caused by TAP, GMTA, and WMTA but not by BD, RRM, and RRMF. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. Resonance Tests on Glass Reinforced Plastic Composite Panels.

    DTIC Science & Technology

    1981-04-01

    glass -- fibre woven roving and glass - fibre chopped strand mat. BP Cellobond A2785-CV resin was used to bond the glass fibre layers to the foam. A rib was...foam slabs were filled with putty. The differences between the panels were the number of layers of glass fibre used on each side, the density of the...ORGANISATION AERONAUTICAL RESEARCH LABORATORIES MELBOURNE, VICTORIA Structures Technical Memorandum 329 RESONANCE TESTS O GLASS REINFORCED PLASTIC

  10. Laboratory Activity: Specific Heat by Change in Internal Energy of Silly Putty

    NASA Astrophysics Data System (ADS)

    Koser, John

    2011-12-01

    Students in introductory physics courses often don't study thermodynamics or thermodynamic events. If any thermal physics is taught in introductory courses (e.g., Physics 101 for Liberal Arts Majors), it usually involves the concepts of specific heat and various temperature scales. Seldom are the first and second laws of thermodynamics taught in detail. In this article, we look at a means to obtain real-time data that will lead to clarifying the first law.

  11. [Iconography of embryos and fetuses in the treaties of delivery and anatomy from 16th century till 18th century].

    PubMed

    Morel, Marie-France

    2009-01-01

    Leonardo', Eurakius' and Jacob Rueff's carved woods focus attention as they are sketches of foetuses in breech presentation. From the very beginning foetus is a little man made in the image of God in the works of Guillemeau, Mauriceau and Viardel. Later the liking for Baroque made the Putti, embryos with kindly faces created in Padua and Venice. Hunter's treatise finishes this picturesque review.

  12. Influence of tray rigidity and impression technique on accuracy of polyvinyl siloxane impressions.

    PubMed

    Hoyos, Alex; Soderholm, Karl-Johan

    2011-01-01

    The aim of this study was to determine how tray rigidity and impression technique affect the accuracy of polyvinyl siloxane impressions. Disposable plastic trays and metallic Rim-Lock trays were used in combination with a heavy/light body technique or with two different putty-wash techniques. For each technique-tray combination, 10 impressions were made of a master cast with two steel abutments representing the mandibular right first premolar and second molar, between which a steel rod was placed at the ridge level. Each steel abutment had five marks, while the steel rod in between the two abutments had only one mark, which served as a reference point. With a universal measuring microscope, the x-, y-, and z-coordinates were recorded for each mark on the master cast and impressions. The distances between the different marks and the reference point on the impressions were calculated and compared with those of the master cast. All techniques used with the plastic trays had distances that were significantly different from the master cast (P < .05), while for the metal trays, it was only the heavy/light body technique that resulted in distances that were significantly different from the master cast (P < .05). Plastic trays produced less accurate impressions than metal trays. When metal trays were used, putty-based impressions were dimensionally better than heavy/light body impressions.

  13. Palateless custom bar supported overdenture: a treatment modality to treat patient with severe gag reflex.

    PubMed

    Singh, Kunwarjeet; Gupta, Nidhi

    2012-01-01

    To suggest a custom bar supported overdenture treatment modality for prosthodontic management of patients with severe gag reflex. Some patients have a severe gag reflex and cannot tolerate conventional maxillary complete dentures with maximum palatal coverage and extensions of all borders. The condition further gets complicated in patients suffering from respiratory problems along with severe gag reflex. Severe gagging acts as a barrier to treat such patients with accepted clinical procedures and prevent patients from wearing the prosthesis. By saving some of the remaining natural teeth and fabricating, a horse shoe shape palateless simple tooth or bar supported overdenture can be successfully used for treating such patients. The remaining maxillary right and left canines were prepared with the tapered round end diamond bur to receive copings of custom bar after intentional root canal treatment of same teeth. Impression was made with light body and putty of the polyvinyl siloxane elastomer with double step putty wash technique. Impression was poured with die stone. Wax pattern of copings with bar was fabricated with inlay wax which was invested and casted. After retrieving the bar, it was finished and its fit was evaluated. The coping-bar assembly was finally cemented with the glass ionomer cement. Palateless overdenture was fabricated by conventional technique used for the fabrication of complete denture. Palateless custom bar supported overdenture procedure can be successfully used for the management of patients with severe gag reflex with improved denture retention, stability, chewing efficiency and comfort of the patient.

  14. The Masters of the Bolognese Orthopaedic School.

    PubMed

    Di Matteo, Berardo; Tarabella, Vittorio; Filardo, Giuseppe; Tomba, Patrizia; Viganò, Anna; Marcacci, Maurilio

    2016-11-01

    Bologna is one of the most ancient cradles of medical knowledge, as the city hosts one of the oldest medical faculties in the world. Among its best known institutions there is the Rizzoli Orthopaedic Institute, founded in the late nineteenth century, whose history is strictly connected with the evolution and development of the Italian orthopaedic practice of the last 120 years. The present manuscript acknowledges the main contributions by Francesco Rizzoli, Alessandro Codivilla and Vittorio Putti, who prompted the foundation and the international recognition of the Rizzoli Institute and the related Bolognese Orthopaedic School.

  15. Clast-fabric development in a shearing granular material: Implications for subglacial till and fault gouge

    USGS Publications Warehouse

    Hooyer, T.S.; Iverson, N.R.

    2000-01-01

    Elongate clasts in subglacial till and in fault gouge align during shearing, but the relation between clast-fabric strength and cumulative shear strain for such materials is effectively unknown. This relation was explored in experiments with a large ring-shear device in which a till and a viscous putty that contained isolated clasts were sheared to high strains. As expected, rotation of clasts in the putty is closely approximated by the theory of G.B. Jeffrey, who derived the orbits of rigid ellipsoids in a slowly shearing fluid. Clast rotation in the till, however, is strikingly different. Rather than orbiting through the shear plane as predicted by Jeffery, most clasts rotate into the shear plane and remain there, resulting in strong fabrics regardless of the aspect ratios and initial orientations of clasts. This divergent behavior is likely due to slip of the till matrix along the surfaces of clasts, which is a natural expectation in a granular material but violates the no-slip condition of Jeffery's model. These results do not support the widespread belief that subglacial till deformation results in weak clast fabrics. Thus, many tills with weak fabrics thought to have been sheared subglacially to high strains, like many basal tills of the Laurentide Ice Sheet, may have been sheared only slightly with little effect on either ice-sheet dynamics or sediment transport. In addition, these results indicate that in simple shear the rotation of clasts in till and in fault gouge is best analyzed with the model of A. March, who treated inclusions as passive markers.

  16. Identifying the Optimal Water-Occluding Earplugs: A Scientific Simulation Study.

    PubMed

    Kovoor, Joshua; Al Hussaini, Ali; Backhouse, Steven

    2016-12-01

    Numerous types of water-occluding earplugs are available as a means of preventing infection in patients with external and middle ear disease. However, little is known about the comparative efficacies of these earplugs with prolonged water exposure. In this study, we assessed the water impermeability of various earplug materials to prolonged water exposure. Nine earplugs were tested: cotton wool mixed with petroleum jelly, cotton wool externally coated with petroleum jelly, Blu-Tack, foam earplugs, silicone putty, silicone earplugs, flanged earplugs, and hard and soft silicone custom-moulds. Precision-engineered cups were filled with 30 mL water and sealed with lids that contained a 10 mm diameter hole to simulate the ear canal. The aperture was occluded with different earplugs, and the cup was inverted. Computer software was used to record the water loss to the nearest 10 milligrams 720 times over a three-hour period. The test was repeated five times for each material. The water permeability onset, rate, and total amount of water loss varied markedly between the materials; cotton wool mixed with petroleum jelly demonstrated the fastest onset of leak and the highest rate of water loss (p < 0.00001), as well as the largest amount of cumulative water loss (p = 0.00213). The soft silicone custom-mould plugs, hard silicone custom-mould plugs, foam plugs, and silicone putty demonstrated no leaks. This study demonstrates a wide range of water permeabilities of commonly used ear-occluding materials during prolonged water exposure. We found that the generally suggested regimen of cotton wool mixed with petroleum jelly may be inefficacious for substantial periods of water exposure.

  17. Fabrication of Single Crystal MgO Capsules

    NASA Technical Reports Server (NTRS)

    Danielson, Lisa

    2012-01-01

    A method has been developed for machining MgO crystal blocks into forms for containing metallic and silicate liquids at temperatures up to 2,400 C, and pressures up to at least 320 kilobars. Possible custom shapes include tubes, rods, insulators, capsules, and guides. Key differences in this innovative method include drilling along the crystallographic zone axes, use of a vibration minimizing material to secure the workpiece, and constant flushing of material swarf with a cooling medium/lubricant (water). A single crystal MgO block is cut into a section .5 mm thick, 1 cm on a side, using a low-speed saw with a 0.004 blade. The cut is made parallel to the direction of cleavage. The block may be cut to any thickness to achieve the desired length of the piece. To minimize drilling vibrations, the MgO block is mounted on a piece of adhesive putty in a vise. The putty wad cradles the bottom half of the entire block. Diamond coring tools are used to drill the MgO to the desired custom shape, with water used to wet and wash the surface of swarf. Compressed air may also be used to remove swarf during breaks in drilling. The MgO workpiece must be kept cool at all times with water. After all the swarf is rinsed off, the piece is left to dry overnight. If the workpiece is still attached to the base of the MgO block after drilling, it may be cut off by using a diamond cutoff wheel on a rotary hand tool or by using a low-speed saw.

  18. Engineering bone grafts with enhanced bone marrow and native scaffolds.

    PubMed

    Hung, Ben P; Salter, Erin K; Temple, Josh; Mundinger, Gerhard S; Brown, Emile N; Brazio, Philip; Rodriguez, Eduardo D; Grayson, Warren L

    2013-01-01

    The translation of tissue engineering approaches to the clinic has been hampered by the inability to find suitable multipotent cell sources requiring minimal in vitro expansion. Enhanced bone marrow (eBM), which is obtained by reaming long bone medullary canals and isolating the solid marrow putty, has large quantities of stem cells and demonstrates significant potential to regenerate bone tissues. eBM, however, cannot impart immediate load-bearing mechanical integrity or maintain the gross anatomical structure to guide bone healing. Yet, its putty-like consistency creates a challenge for obtaining the uniform seeding necessary to effectively combine it with porous scaffolds. In this study, we examined the potential for combining eBM with mechanically strong, osteoinductive trabecular bone scaffolds for bone regeneration by creating channels into scaffolds for seeding the eBM. eBM was extracted from the femurs of adult Yorkshire pigs using a Synthes reamer-irrigator-aspirator device, analyzed histologically, and digested to extract cells and characterize their differentiation potential. To evaluate bone tissue formation, eBM was seeded into the channels in collagen-coated or noncoated scaffolds, cultured in osteogenic conditions for 4 weeks, harvested and assessed for tissue distribution and bone formation. Our data demonstrates that eBM is a heterogenous tissue containing multipotent cell populations. Furthermore, coating scaffolds with a collagen hydrogel significantly enhanced cellular migration, promoted uniform tissue development and increased bone mineral deposition. These findings suggest the potential for generating customized autologous bone grafts for treating critical-sized bone defects by combining a readily available eBM cell source with decellularized trabecular bone scaffolds. © 2013 S. Karger AG, Basel

  19. The efficacy of different commercially available demineralized bone matrix substances in an athymic rat model.

    PubMed

    Lee, Yu-Po; Jo, Mark; Luna, Mario; Chien, Bobby; Lieberman, Jay R; Wang, Jeffrey C

    2005-10-01

    Bone graft substitutes have been developed because there is a limited supply of autogenous graft and the harvesting of iliac crest bone graft is associated with significant morbidity. Currently, there are a number of different commercially available demineralized bone matrix (DBM) products available that have been prepared by different methods and have different carriers. The objective of this study was to compare eight different commercially available DBM products. Eight different DBMs were used to attempt a spinal fusion between the L4-L5 transverse processes in athymic rats. There were 10 rats in each group, and 5 rats were killed at both 4 and 8 weeks. Radiographic and histologic analyses were performed. Manual palpation testing was also performed. At 4 weeks, Osteofil Paste had the highest radiographic scores, whereas Grafton Putty had the best radiographic scores at 8 weeks. Conversely, the spines implanted with Allomatrix had the lowest radiographic scores at both 4 and 8 weeks. In regard to forming a spinal fusion confirmed by manual palpation, Osteofil Paste was the most effective at 4 weeks, whereas Grafton Flex and Grafton Putty had the highest rate of fusion at 8 weeks. Conversely, the lowest rates of fusion were seen in the Allomatrix and Grafton Crunch groups. Statistical analysis showed that there were significant differences among the groups seen on radiographs and by manual palpation. Qualitative differences could be appreciated between the groups histologically. Significant differences exist among commercially available DBMs in forming a spinal fusion in an athymic rat.

  20. Bone Tissue Engineering Under Xenogeneic-Free Conditions in a Large Animal Model as a Basis for Early Clinical Applicability.

    PubMed

    Weigand, Annika; Beier, Justus P; Schmid, Rafael; Knorr, Tobias; Kilian, David; Götzl, Rebekka; Gerber, Thomas; Horch, Raymund E; Boos, Anja M

    2017-03-01

    For decades, researchers have been developing a range of promising strategies in bone tissue engineering with the aim of producing a significant clinical benefit over existing therapies. However, a major problem concerns the traditional use of xenogeneic substances for the expansion of cells, which complicates direct clinical transfer. The study's aim was to establish a totally autologous sheep model as a basis for further preclinical studies and future clinical application. Ovine mesenchymal stromal cells (MSC) were cultivated in different concentrations (0%, 2%, 5%, 10%, and 25%) of either autologous serum (AS) or fetal calf serum (FCS). With an increase of serum concentration, enhanced metabolic activity and proliferation could be observed. There were minor differences between MSC cultivated in AS or FCS, comparing gene and protein expression of osteogenic and stem cell markers, morphology, and osteogenic differentiation. MSC implanted subcutaneously in the sheep model, together with a nanostructured bone substitute, either in stable block or moldable putty form, induced similar vascularization and remodeling of the bone substitute irrespective of cultivation of MSC in AS or FCS and osteogenic differentiation. The bone substitute in block form together with MSC proved particularly advantageous in the induction of ectopic bone formation compared to the cell-free control and putty form. It could be demonstrated that AS is suitable for replacement of FCS for cultivation of ovine MSC for bone tissue engineering purposes. Substantial progress has been made in the development of a strictly xenogeneic-free preclinical animal model to bring future clinical application of bone tissue engineering strategies within reach.

  1. In vivo Study of the Accuracy of Dual-arch Impressions.

    PubMed

    de Lima, Luciana Martinelli Santayana; Borges, Gilberto Antonio; Junior, Luiz Henrique Burnett; Spohr, Ana Maria

    2014-06-01

    This study evaluated in vivo the accuracy of metal (Smart®) and plastic (Triple Tray®) dual-arch trays used with vinyl polysiloxane (Flexitime®), in the putty/wash viscosity, as well as polyether (Impregum Soft®) in the regular viscosity. In one patient, an implant-level transfer was screwed on an implant in the mandibular right first molar, serving as a pattern. Ten impressions were made with each tray and impression material. The impressions were poured with Type IV gypsum. The width and height of the pattern and casts were measured in a profile projector (Nikon). The results were submitted to Student's t-test for one sample (α = 0.05). For the width distance, the plastic dual-arch trays with vinyl polysiloxane (4.513 mm) and with polyether (4.531 mm) were statistically wider than the pattern (4.489 mm). The metal dual-arch tray with vinyl polysiloxane (4.504 mm) and with polyether (4.500 mm) did not differ statistically from the pattern. For the height distance, only the metal dual-arch tray with polyether (2.253 mm) differed statistically from the pattern (2.310 mm). The metal dual-arch tray with vinyl polysiloxane, in the putty/wash viscosities, reproduced casts with less distortion in comparison with the same technique with the plastic dual-arch tray. The plastic or metal dual-arch trays with polyether reproduced cast with greater distortion. How to cite the article: Santayana de Lima LM, Borges GA, Burnett LH Jr, Spohr AM. In vivo study of the accuracy of dual-arch impressions. J Int Oral Health 2014;6(3):50-5.

  2. Bilateral Complete and Incomplete Fusion of Incisors and its Management.

    PubMed

    Da Costa, Godwin Clovis; Chalakkal, Paul; De Souza, Neil; Gavhane, Sanket

    2017-01-01

    This case report highlights the management of a case of bilateral complete and incomplete fusion of maxillary incisors in a 10-year-old child. A mock-up was done on the diagnostic cast. Pretreatment esthetic evaluation was done using bis-acryl composite temporaries which were transferred intraorally from the diagnostic cast using a putty index. An incisal overlap veneer preparation was done, following which, an IPS e-max veneer was cemented. A digital mock-up was carried out using the Adobe Photoshop and Corel Draw softwares to aid in laboratorial fabrication of the veneer.

  3. Verification and Demonstration for Transition of Nonhexavalent Chromium, Low-Volatile Organic Compound (VOC) Alternative Technologies to Replace DOD-P-15328 Wash Primer for Multimetal Applications

    DTIC Science & Technology

    2017-09-28

    DTL-53030 at 1008 h Aluminum panels were run out to 1008 h of exposure in ASTM B117 testing. The results obtained can be seen in Table 13. At 1008...were scraped with a 2-inch flat blade putty knife after rating to unveil any previously unseen corrosion or delamination issues between the coating and...CRS primed with MIL-DTL-53022 after 80 cycles Although success is established at 40 cycles, the aluminum test panels were also run out to 80 cycles

  4. Portland cement based fast-setting concrete demonstration, district 07, Los Angeles County

    DOT National Transportation Integrated Search

    2001-09-01

    The California Department of Transportation currently uses fast-setting concrete to accommodate short working windows. The current special provision for fast-setting concrete requires that the concrete reach a flexural strength of 2.8 MPa (400 psi) b...

  5. How honey bees carry pollen

    NASA Astrophysics Data System (ADS)

    Matherne, Marguerite E.; Anyanwu, Gabriel; Leavey, Jennifer K.; Hu, David L.

    2017-11-01

    Honey bees are the tanker of the skies, carrying thirty percent of their weight in pollen per foraging trip using specialized orifices on their body. How do they manage to hang onto those pesky pollen grains? In this experimental study, we investigate the adhesion force of pollen to the honeybee. To affix pollen to themselves, honey bees form a suspension of pollen in nectar, creating a putty-like pollen basket that is skewered by leg hairs. We use tensile tests to show that the viscous force of the pollen basket is more than ten times the honeybee's flight force. This work may provide inspiration for the design of robotic flying pollinators.

  6. Wire electric-discharge machining and other fabrication techniques

    NASA Technical Reports Server (NTRS)

    Morgan, W. H.

    1983-01-01

    Wire electric discharge machining and extrude honing were used to fabricate a two dimensional wing for cryogenic wind tunnel testing. Electric-discharge cutting is done with a moving wire electrode. The cut track is controlled by means of a punched-tape program and the cutting feed is regulated according to the progress of the work. Electric-discharge machining involves no contact with the work piece, and no mechanical force is exerted. Extrude hone is a process for honing finish-machined surfaces by the extrusion of an abrasive material (silly putty), which is forced through a restrictive fixture. The fabrication steps are described and production times are given.

  7. Performance of fast-setting impression materials in the reproduction of subgingival tooth surfaces without soft tissue retraction.

    PubMed

    Rudolph, Heike; Röhl, Andreas; Walter, Michael H; Luthardt, Ralph G; Quaas, Sebastian

    2014-01-01

    Fast-setting impression materials may be prone to inaccuracies due to accidental divergence from the recommended mixing protocol. This prospective randomized clinical trial aimed to assess three-dimensional (3D) deviations in the reproduction of subgingival tooth surfaces and to determine the effect of either following or purposely diverging from the recommended mixing procedure for a fast-setting addition-curing silicone (AS) and fast-setting polyether (PE). After three impressions each were taken from 96 participants, sawcut gypsum casts were fabricated with a standardized procedure and then optically digitized. Data were assessed with a computer-aided 3D analysis. For AS impressions, multivariate analysis of variance revealed a significant influence of the individual tooth and the degree to which the recommended mixing protocol was violated. For PE impressions, the ambient air temperature and individual tooth showed significant effects, while divergence from the recommended mixing protocol was not of significance. The fast-setting PE material was not affected by changes in the recommended mixing protocol. For the two fast-setting materials examined, no divergences from the recommended mixing protocol of less than 2 minutes led to failures in the reproduction of the subgingival tooth surfaces.

  8. [Physiokinesitherapeutic management of traumatic lesions of the brachial plexus. Indications and results].

    PubMed

    Gusso, M I; Innocenti, M; Mauceri, M C

    1985-03-31

    An account is given of the indications and results of physical and rehabilitative management of brachial plexus lesions when used electively or as a complement to surgery. Material from the Florence Traumatological and Orthopaedics Centre and the V. Putti Mutilated Patients Centre, Bologna (formerly directed by Prof. O. Scaglietti) dating from 1940 to 1980 is used to explain the indications for conservative and surgical management, in the conviction that sound results depend on exact indication. A selected sample of 51 patients treated conservatively and 194 surgically is presented. The results were satisfactory in about 50% of each group, with a slight advantage in favour of physiotherapy, this being obviously employed when lesions were less severe.

  9. A Brief History of Limb Lengthening.

    PubMed

    Birch, John G

    2017-09-01

    In the last 35 years, orthopaedic surgeons have witnessed 3 major advances in the technique of limb lengthening: "distraction osteogenesis" facilitated by Gavriil Ilizarov method and infinitely-adaptable circular fixator with fine-wire bone fragment fixation; the introduction of the "6-strut" computer program-assisted circular fixators to effect complex deformity correction simultaneously; and the development of motorized intramedullary lengthening nails. However, the principles and associated complications of these techniques are on the basis of observations by Codivilla, Putti, and Abbott from as much as 110 years ago. This review notes the contribution of these pioneers in limb lengthening, and the contribution of Thor Heyerdahl principles of tolerance and diversity to the dissemination of Ilizarov principles to the Western world.

  10. The Neuropsychology of Starvation: Set-Shifting and Central Coherence in a Fasted Nonclinical Sample

    PubMed Central

    Pender, Sarah; Gilbert, Sam J.; Serpell, Lucy

    2014-01-01

    Objectives Recent research suggests certain neuropsychological deficits occur in anorexia nervosa (AN). The role of starvation in these deficits remains unclear. Studies of individuals without AN can elucidate our understanding of the effect of short-term starvation on neuropsychological performance. Methods Using a within-subjects repeated measures design, 60 healthy female participants were tested once after fasting for 18 hours, and once when satiated. Measures included two tasks to measure central coherence and a set-shifting task. Results Fasting exacerbated set-shifting difficulties on a rule-change task. Fasting was associated with stronger local and impaired global processing, indicating weaker central coherence. Conclusions Models of AN that propose a central role for set-shifting difficulties or weak central coherence should also consider the impact of short-term fasting on these processes. PMID:25338075

  11. The experimental basis for interpreting particle and magnetic fabrics of sheared till

    USGS Publications Warehouse

    Iverson, N.R.; Hooyer, T.S.; Thomason, J.F.; Graesch, M.; Shumway, J.R.

    2008-01-01

    Particle fabrics of basal tills may allow testing of the bed-deformation model of glacier flow, which requires high bed shear strains (>100). Field studies, however, have not yielded a systematic relationship between shear-strain magnitude and fabric development. To isolate this relationship four basal tills and viscous putty were sheared in a ring-shear device to strains as high as 714. Fabric was characterized within a zone of shear deformation using the long-axis orientations of fine-gravel and sand particles and the anisotropy of magnetic susceptibility (AMS) of small (???5-8 cm3) intact samples. Results indicate that till particles rotate toward the plane of shearing with long-axis orientations that become tightly clustered in the direction of shear (0??78 < S1 < 0??94 for three-dimensional data). These strong, steady-state fabrics are attained at shear strains of 7-30, with no evidence of fabric weakening with further strain, regardless of the specific till or particle-size fraction under consideration. These results do not support the Jeffery model of particle rotation, which correctly describes particle rotation in the viscous putty but not in the tills, owing to fluid-mechanical assumptions of the model that are violated in till. The sensitivity of fabric development to shear-strain magnitude indicates that, for most till units where shear-strain magnitude is poorly known, attributing fabric variations to spatial differences in other variables, such as till thickness or water content, will be inherently speculative. Attributing fabric characteristics to particular basal till facies is uncertain because shear-strain magnitude is unlikely to be closely correlated to till facies. Weak or spatially variable fabrics, in the absence of post-depositional disturbance or major deviations from unidirectional simple shear, indicate that till has not been pervasively sheared to the high strains required by the bed-deformation model. Strong flow-parallel fabrics are a necessary but insufficient criterion for confirming the model. Copyright ?? 2008 John Wiley & Sons, Ltd.

  12. A comparison of the accuracy of polyether, polyvinyl siloxane, and plaster impressions for long-span implant-supported prostheses.

    PubMed

    Hoods-Moonsammy, Vyonne J; Owen, Peter; Howes, Dale G

    2014-01-01

    The purpose of this study was to compare the capacity of different impression materials to accurately reproduce the positions of five implant analogs on a master model by comparing the resulting cast with the stainless steel master model. The study was motivated by the knowledge that distortions can occur during impression making and the pouring of casts and that this distortion may produce inaccuracies of subsequent restorations, especially long-span castings for implant superstructures. The master model was a stainless steel model with five implant analogs. The impression materials used were impression plaster (Plastogum, Harry J Bosworth), a polyether (Impregum Penta, 3M ESPE), and two polyvinyl siloxane (PVS) materials (Aquasil Monophase and Aquasil putty with light-body wash, Dentsply). Five impressions were made with each impression material and cast in die stone under strictly controlled laboratory conditions. The positions of the implants on the master model, the impression copings, and the implant analogs in the subsequent casts were measured using a coordinate measuring machine that measures within 4 μm of accuracy. Statistical analyses indicated that distortion occurred in all of the impression materials, but inconsistently. The PVS monophase material reproduced the master model most accurately. Although there was no significant distortion between the impressions and the master model or between the impressions and their casts, there were distortions between the master model and the master casts, which highlighted the cumulative effects of the distortions. The polyether material proved to be the most reliable in terms of predictability. The impression plaster displayed cumulative distortion, and the PVS putty with light body showed the least reliability. Some of the distortions observed are of clinical significance and likely to contribute to a lack of passive fit of any superstructure. The inaccuracy of these analog materials and procedures suggested that greater predictability may lie in digital technology.

  13. Comparative evaluation of border molding, using two different techniques in maxillary edentulous arches - An in vivo study

    PubMed Central

    Yarapatineni, Rameshbabu; Vilekar, Abhishek; Kumar, J Phani; Kumar, G Ajay; Aravind, Prasad; Kumar, P Anil

    2013-01-01

    Background: This study was undertaken to compare the retention between sectional border molding using low fusing greenstick compound and single step border molding using condensation silicone (putty) impression material in three stages- A. Immediately following border molding, B. After final impression and C. With the finished permanent denture base. Materials & Methods: In this study evaluation of retentive values of sectional border molding (Group I) (custom impression trays border molded with green stick compound ) and single step border molding (Group II) ( border molding with condensation silicone (putty) impression material ). In both techniques definitive wash impression were made with light body condensation silicone and permanent denture base with heat cure polymerization resin. Results: Group II was significantly higher (mean=8011.43) than Group I (mean=5777.43) in test-A. The t-value (1.5883) infers that there was significant difference between Group I and Group II (p =0.15). Group I was significantly higher (mean=6718.57) than Group II (mean=5224.29) in test -B. The t-value (1.6909) infers that there was significant difference between Group I and Group II (p=0.17). Group II was higher (mean=4025.14) than Group I (mean=3835.07) in test -C. The t-value was 0.1239. But it was found to be statistically insignificant (p=0.005). Conclusion: Within the limitation of this clinical study border molding custom tray with low fusing green stick compound provided similar retention as compared to custom impression tray with condensation silicone in permanent denture base. How to cite this article: Yarapatineni R, Vilekar A, Kumar JP, Kumar GA, Aravind P, Kumar PA. Comparative evaluation of border molding, using two different techniques in maxillary edentulous arches - An in vivo study. J Int Oral Health 2013; 5(6):82-7 . PMID:24453450

  14. A novel digital workflow to manufacture personalized three-dimensional-printed hollow surgical obturators after maxillectomy.

    PubMed

    Kortes, J; Dehnad, H; Kotte, A N T; Fennis, W M M; Rosenberg, A J W P

    2018-04-07

    Partial or complete resection of the maxilla during tumour surgery causes oronasal defects, leading to oral-maxillofacial dysfunction, for which the surgical obturator (SO) is an important treatment option. Traditional manufacturing of SOs is complex, time-consuming, and often results in inadequate fit and function. This technical note describes a novel digital workflow to design and manufacture a three-dimensional (3D)-printed hollow SO. Registered computed tomography and magnetic resonance imaging images are used for gross tumour delineation. The produced RTStruct set is exported as a stereolitography (STL) file and merged with a 3D model of the dental status. Based on these merged files, a personalized and hollow digital SO design is created, and 3D printed. Due to the proper fit of the prefabricated SO, a soft silicone lining material can be used during surgery to adapt the prosthesis to the oronasal defect, instead of putty materials that are not suitable for this purpose. An STL file of this final SO is created during surgery, based on a scan of the relined SO. The digital workflow results in a SO weight reduction, an increased fit, an up-to-date digital SO copy, and overall easier clinical handling. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  15. Fasting: a major limitation for resistance exercise training effects in rodents

    PubMed Central

    das Neves, W.; de Oliveira, L.F.; da Silva, R.P.; Alves, C.R.R.; Lancha, A.H.

    2017-01-01

    Protocols that mimic resistance exercise training (RET) in rodents present several limitations, one of them being the electrical stimulus, which is beyond the physiological context observed in humans. Recently, our group developed a conditioning system device that does not use electric shock to stimulate rats, but includes fasting periods before each RET session. The current study was designed to test whether cumulative fasting periods have some influence on skeletal muscle mass and function. Three sets of male Wistar rats were used in the current study. The first set of rats was submitted to a RET protocol without food restriction. However, rats were not able to perform exercise properly. The second and third sets were then randomly assigned into three experimental groups: 1) untrained control rats, 2) untrained rats submitted to fasting periods, and 3) rats submitted to RET including fasting periods before each RET session. While the second set of rats performed a short RET protocol (i.e., an adaptation protocol for 3 weeks), the third set of rats performed a longer RET protocol including overload (i.e., 8 weeks). After the short-term protocol, cumulative fasting periods promoted loss of weight (P<0.001). After the longer RET protocol, no difference was observed for body mass, extensor digitorum longus (EDL) morphology or skeletal muscle function (P>0.05 for all). Despite no effects on EDL mass, soleus muscle displayed significant atrophy in the fasting experimental groups (P<0.01). Altogether, these data indicate that fasting is a major limitation for RET in rats. PMID:29185588

  16. Fasting: a major limitation for resistance exercise training effects in rodents.

    PubMed

    das Neves, W; de Oliveira, L F; da Silva, R P; Alves, C R R; Lancha, A H

    2017-11-17

    Protocols that mimic resistance exercise training (RET) in rodents present several limitations, one of them being the electrical stimulus, which is beyond the physiological context observed in humans. Recently, our group developed a conditioning system device that does not use electric shock to stimulate rats, but includes fasting periods before each RET session. The current study was designed to test whether cumulative fasting periods have some influence on skeletal muscle mass and function. Three sets of male Wistar rats were used in the current study. The first set of rats was submitted to a RET protocol without food restriction. However, rats were not able to perform exercise properly. The second and third sets were then randomly assigned into three experimental groups: 1) untrained control rats, 2) untrained rats submitted to fasting periods, and 3) rats submitted to RET including fasting periods before each RET session. While the second set of rats performed a short RET protocol (i.e., an adaptation protocol for 3 weeks), the third set of rats performed a longer RET protocol including overload (i.e., 8 weeks). After the short-term protocol, cumulative fasting periods promoted loss of weight (P<0.001). After the longer RET protocol, no difference was observed for body mass, extensor digitorum longus (EDL) morphology or skeletal muscle function (P>0.05 for all). Despite no effects on EDL mass, soleus muscle displayed significant atrophy in the fasting experimental groups (P<0.01). Altogether, these data indicate that fasting is a major limitation for RET in rats.

  17. Single Visit Feeding Appliance for 1-day-old Neonate with Cleft Palate Using Safe Dental Putty-Gauze Hybrid Impression Technique for Maxillary Impression.

    PubMed

    Rathee, Manu

    2015-01-01

    Cleft lip and palate is one of the most common craniofacial anomalies of humans. Intraoral impression making is the first clinical step in the fabrication of feeding appliance for infants with oro-nasal communication. It is difficult to control the flow of the impression material in the cleft area and undercuts in a child patient. This clinical report presents a simple and safe impression technique for maxillary impression making in neonates and infants with cleft palate. A gauze piece was used to confine the impression material during functional movements of sucking while impression making in an awake child to avoid the risk of aspiration or swallowing.

  18. KSC-2009-6811

    NASA Image and Video Library

    2009-12-14

    CAPE CANAVERAL, Fla. - In Orbiter Processing Facility Bay 1 at NASA's Kennedy Space Center in Florida, United Space Alliance technician Jeff Holmes uses heat lamps in a putty repair on some of the high-temperature reusable surface insulation tiles, or HRSI tiles, on the lower forward fuselage of space shuttle Atlantis. An average of 125 tiles are replaced after each mission either due to handling damage or accumulated repairs. These black tiles are optimized for maximum emissivity, which means they lose heat faster than white tiles. This property is required to maximize heat rejection during the hot phase of reentry. Atlantis next is slated to deliver an Integrated Cargo Carrier and Russian-built Mini Research Module to the International Space Station on the STS-132 mission. Launch is targeted for May 14, 2010. Photo credit: NASA/Jack Pfaller

  19. KSC-2009-6812

    NASA Image and Video Library

    2009-12-14

    CAPE CANAVERAL, Fla. - In Orbiter Processing Facility Bay 1 at NASA's Kennedy Space Center in Florida, heat lamps assist United Space Alliance technician Jeff Holmes in a putty repair on some of the high-temperature reusable surface insulation tiles, or HRSI tiles, on the lower forward fuselage of space shuttle Atlantis. An average of 125 tiles are replaced after each mission either due to handling damage or accumulated repairs. These black tiles are optimized for maximum emissivity, which means they lose heat faster than white tiles. This property is required to maximize heat rejection during the hot phase of reentry. Atlantis next is slated to deliver an Integrated Cargo Carrier and Russian-built Mini Research Module to the International Space Station on the STS-132 mission. Launch is targeted for May 14, 2010. Photo credit: NASA/Jack Pfaller

  20. KSC-2009-6810

    NASA Image and Video Library

    2009-12-14

    CAPE CANAVERAL, Fla. - In Orbiter Processing Facility Bay 1 at NASA's Kennedy Space Center in Florida, United Space Alliance technician Jeff Holmes makes a putty repair on some of the high-temperature reusable surface insulation tiles, or HRSI tiles, on the lower forward fuselage of space shuttle Atlantis. An average of 125 tiles are replaced after each mission either due to handling damage or accumulated repairs. These black tiles are optimized for maximum emissivity, which means they lose heat faster than white tiles. This property is required to maximize heat rejection during the hot phase of reentry. Atlantis next is slated to deliver an Integrated Cargo Carrier and Russian-built Mini Research Module to the International Space Station on the STS-132 mission. Launch is targeted for May 14, 2010. Photo credit: NASA/Jack Pfaller

  1. STS-114 Flight Day 5 Highlights

    NASA Technical Reports Server (NTRS)

    2005-01-01

    Highlights of Day 5 of the STS-114 Return to Flight mission (Commander Eileen Collins, Pilot James Kelly, Mission Specialists Soichi Noguchi, Stephen Robinson, Andrew Thomas, Wendy Lawrence, and Charles Camarda) include video coverage of an extravehiclular activity (EVA) by Noguchi and Robinson. The other crew members of Discovery are seen on the flight deck and mid-deck helping the astronauts to suit-up. The objectives of the EVA are to test repair techniques on sample tiles in the shuttle's payload bay, to repair electrical equipment for a gyroscope on the International Space Station (ISS), and to install a replacement GPS antenna on the ISS. Noguchi and Robinson use a caulk gun and a putty knife to repair the sample tiles. The video contains several Earth views, including one of Baja California.

  2. Construction, Instrumentation, and Testing of Fast-Setting Hydraulic Cement Concrete in Palmdale, California

    DOT National Transportation Integrated Search

    2000-08-01

    To minimize the lane closure time for construction, Caltrans is exploring the use of fast-setting hydraulic cement concrete (FSHCC). The principal property of the FSHCC is its high early strength gain. This accelerated strength gain would increase th...

  3. Accuracy of intraoral data acquisition in comparison to the conventional impression.

    PubMed

    Luthardt, R G; Loos, R; Quaas, S

    2005-10-01

    The achievable accuracy is a decisive parameter for the comparison of direct intraoral digitization with the conventional impression. The objective of the study was therefore to compare the accuracy of the reproduction of a model situation by intraoral digitization vs. the conventional procedure consisting of impression taking, model production, and extraoral digitization. Proceeding from a die model with a prepared tooth 16, the reference data set of the teeth 15, 16 and 17 was produced with an established procedure by means ofextraoral digitization. For the simulated intraoral data acquisition of the master model (Cerec 3D camera, Sirona, Bensheim), the camera was fastened on a stand for the measurement and the teeth digitized seven times each in defined views (occlusal, and in each case inclined by 20 degrees, from the mesio-proximal, disto-proximal, vestibular and oral aspect). Matching was automated (comparative data sets B1-B5). A clinically perfect one-step putty-and-wash impression was taken from the starting model. The model produced under defined conditions was digitized extraorally five times (digi-SCAN, comparative data sets C1-C5). The data sets B1-B5 and C1-C5 were assigned to the reference data set by means of best-fit matching and the root of the mean quadratic deviation (RMS; root mean square) calculated. The deviations were visualized, and mean positive, negative and absolute deviations calculated. The mean RMS was 27.9 microm (B1-B5) or 18.8 microm (C1-C5). The mean deviations for the prepared tooth were 18 microm/-17 microm (B1-B5) and 9 microm /-9 microm (C1-C5). For tooth 15, the mean deviations were 22 microm/-19 microm (B1-B5) and 15 microm/-16 microm (C1-C5). The intraoral method showed good results with deviations from the CAD starting model of approx. 17 microm, related to the prepared tooth 16. On the whole, in this in-vitro study, extraoral digitization with impression taking and model production showed higher accuracy than intraoral digitization. Since the inaccuracies in the conventional impression under real clinical conditions may be higher than the values determined above, a comparison under clinical conditions should be performed subsequently.

  4. Fast graph-based relaxed clustering for large data sets using minimal enclosing ball.

    PubMed

    Qian, Pengjiang; Chung, Fu-Lai; Wang, Shitong; Deng, Zhaohong

    2012-06-01

    Although graph-based relaxed clustering (GRC) is one of the spectral clustering algorithms with straightforwardness and self-adaptability, it is sensitive to the parameters of the adopted similarity measure and also has high time complexity O(N(3)) which severely weakens its usefulness for large data sets. In order to overcome these shortcomings, after introducing certain constraints for GRC, an enhanced version of GRC [constrained GRC (CGRC)] is proposed to increase the robustness of GRC to the parameters of the adopted similarity measure, and accordingly, a novel algorithm called fast GRC (FGRC) based on CGRC is developed in this paper by using the core-set-based minimal enclosing ball approximation. A distinctive advantage of FGRC is that its asymptotic time complexity is linear with the data set size N. At the same time, FGRC also inherits the straightforwardness and self-adaptability from GRC, making the proposed FGRC a fast and effective clustering algorithm for large data sets. The advantages of FGRC are validated by various benchmarking and real data sets.

  5. Sensitive electromechanical sensors using viscoelastic graphene-polymer nanocomposites.

    PubMed

    Boland, Conor S; Khan, Umar; Ryan, Gavin; Barwich, Sebastian; Charifou, Romina; Harvey, Andrew; Backes, Claudia; Li, Zheling; Ferreira, Mauro S; Möbius, Matthias E; Young, Robert J; Coleman, Jonathan N

    2016-12-09

    Despite its widespread use in nanocomposites, the effect of embedding graphene in highly viscoelastic polymer matrices is not well understood. We added graphene to a lightly cross-linked polysilicone, often encountered as Silly Putty, changing its electromechanical properties substantially. The resulting nanocomposites display unusual electromechanical behavior, such as postdeformation temporal relaxation of electrical resistance and nonmonotonic changes in resistivity with strain. These phenomena are associated with the mobility of the nanosheets in the low-viscosity polymer matrix. By considering both the connectivity and mobility of the nanosheets, we developed a quantitative model that completely describes the electromechanical properties. These nanocomposites are sensitive electromechanical sensors with gauge factors >500 that can measure pulse, blood pressure, and even the impact associated with the footsteps of a small spider. Copyright © 2016, American Association for the Advancement of Science.

  6. Improved FFT-based numerical inversion of Laplace transforms via fast Hartley transform algorithm

    NASA Technical Reports Server (NTRS)

    Hwang, Chyi; Lu, Ming-Jeng; Shieh, Leang S.

    1991-01-01

    The disadvantages of numerical inversion of the Laplace transform via the conventional fast Fourier transform (FFT) are identified and an improved method is presented to remedy them. The improved method is based on introducing a new integration step length Delta(omega) = pi/mT for trapezoidal-rule approximation of the Bromwich integral, in which a new parameter, m, is introduced for controlling the accuracy of the numerical integration. Naturally, this method leads to multiple sets of complex FFT computations. A new inversion formula is derived such that N equally spaced samples of the inverse Laplace transform function can be obtained by (m/2) + 1 sets of N-point complex FFT computations or by m sets of real fast Hartley transform (FHT) computations.

  7. fast_protein_cluster: parallel and optimized clustering of large-scale protein modeling data.

    PubMed

    Hung, Ling-Hong; Samudrala, Ram

    2014-06-15

    fast_protein_cluster is a fast, parallel and memory efficient package used to cluster 60 000 sets of protein models (with up to 550 000 models per set) generated by the Nutritious Rice for the World project. fast_protein_cluster is an optimized and extensible toolkit that supports Root Mean Square Deviation after optimal superposition (RMSD) and Template Modeling score (TM-score) as metrics. RMSD calculations using a laptop CPU are 60× faster than qcprot and 3× faster than current graphics processing unit (GPU) implementations. New GPU code further increases the speed of RMSD and TM-score calculations. fast_protein_cluster provides novel k-means and hierarchical clustering methods that are up to 250× and 2000× faster, respectively, than Clusco, and identify significantly more accurate models than Spicker and Clusco. fast_protein_cluster is written in C++ using OpenMP for multi-threading support. Custom streaming Single Instruction Multiple Data (SIMD) extensions and advanced vector extension intrinsics code accelerate CPU calculations, and OpenCL kernels support AMD and Nvidia GPUs. fast_protein_cluster is available under the M.I.T. license. (http://software.compbio.washington.edu/fast_protein_cluster) © The Author 2014. Published by Oxford University Press.

  8. Coupling surface and mantle dynamics: A novel experimental approach

    NASA Astrophysics Data System (ADS)

    Kiraly, Agnes; Faccenna, Claudio; Funiciello, Francesca; Sembroni, Andrea

    2015-05-01

    Recent modeling shows that surface processes, such as erosion and deposition, may drive the deformation of the Earth's surface, interfering with deeper crustal and mantle signals. To investigate the coupling between the surface and deep process, we designed a three-dimensional laboratory apparatus, to analyze the role of erosion and sedimentation, triggered by deep mantle instability. The setup is constituted and scaled down to natural gravity field using a thin viscous sheet model, with mantle and lithosphere simulated by Newtonian viscous glucose syrup and silicon putty, respectively. The surface process is simulated assuming a simple erosion law producing the downhill flow of a thin viscous material away from high topography. The deep mantle upwelling is triggered by the rise of a buoyant sphere. The results of these models along with the parametric analysis show how surface processes influence uplift velocity and topography signals.

  9. A sequential approach in treatment of perio-endo lesion

    PubMed Central

    Narang, Sumit; Narang, Anu; Gupta, Ruby

    2011-01-01

    The success of a combined periodontal and endodontic lesion depends on the elimination of both of these disease processes. In the case of a combined endo-perio lesion, the endodontic therapy results in healing of the endodontic component of involvement while the prognosis of tooth would finally depend on the healing of the periodontal structures. This case report evaluates the efficacy of bioactive glass in the management of furcation defect associated with an endo-perio lesion in a right mandibular first molar. A 22-year-old male patient with an endo-perio lesion in the right mandibular first molar was initially treated with endodontic therapy. Following the endodontic treatment, the furcation defect was treated using bioactive glass in a putty form. At the end of 9 months, there was a gain in the clinical attachment level and reduction in probing depth. Radiographic evidence showed that there was a significant bony fill. PMID:21976845

  10. A sequential approach in treatment of perio-endo lesion.

    PubMed

    Narang, Sumit; Narang, Anu; Gupta, Ruby

    2011-04-01

    The success of a combined periodontal and endodontic lesion depends on the elimination of both of these disease processes. In the case of a combined endo-perio lesion, the endodontic therapy results in healing of the endodontic component of involvement while the prognosis of tooth would finally depend on the healing of the periodontal structures. This case report evaluates the efficacy of bioactive glass in the management of furcation defect associated with an endo-perio lesion in a right mandibular first molar. A 22-year-old male patient with an endo-perio lesion in the right mandibular first molar was initially treated with endodontic therapy. Following the endodontic treatment, the furcation defect was treated using bioactive glass in a putty form. At the end of 9 months, there was a gain in the clinical attachment level and reduction in probing depth. Radiographic evidence showed that there was a significant bony fill.

  11. Computer program for fast Karhunen Loeve transform algorithm

    NASA Technical Reports Server (NTRS)

    Jain, A. K.

    1976-01-01

    The fast KL transform algorithm was applied for data compression of a set of four ERTS multispectral images and its performance was compared with other techniques previously studied on the same image data. The performance criteria used here are mean square error and signal to noise ratio. The results obtained show a superior performance of the fast KL transform coding algorithm on the data set used with respect to the above stated perfomance criteria. A summary of the results is given in Chapter I and details of comparisons and discussion on conclusions are given in Chapter IV.

  12. Increasing the speed of medical image processing in MatLab®

    PubMed Central

    Bister, M; Yap, CS; Ng, KH; Tok, CH

    2007-01-01

    MatLab® has often been considered an excellent environment for fast algorithm development but is generally perceived as slow and hence not fit for routine medical image processing, where large data sets are now available e.g., high-resolution CT image sets with typically hundreds of 512x512 slices. Yet, with proper programming practices – vectorization, pre-allocation and specialization – applications in MatLab® can run as fast as in C language. In this article, this point is illustrated with fast implementations of bilinear interpolation, watershed segmentation and volume rendering. PMID:21614269

  13. Influence of chewing rate on salivary stress hormone levels.

    PubMed

    Tasaka, Akinori; Tahara, Yasuaki; Sugiyama, Tetsuya; Sakurai, Kaoru

    2008-10-01

    The purpose of this study was to clarify the effect of different chewing rates on salivary cortisol levels as a stress indicator. The subject group consisted of 16 healthy males. They were required to rest for 30 min, and then given arithmetic calculations to perform for 30 min as stress loading. Immediately after, the first set of saliva specimens (S1) was collected over a period of 1 min to measure cortisol levels. Next, they were asked to chew a tasteless gum base for 10 min, and the second set of saliva specimens (S2) was collected in the same manner. They were then required to rest for 10 min, after which the third set of saliva specimens (S3) was collected. Chewing rates were set to slow, habitual, and fast in time with a metronome. Salivary cortisol levels were analyzed by radioimmunoassay. Changes in salivary cortisol levels comparing S1 with S2, and S1 with S3 were determined. Changes in salivary cortisol levels between S1 and S2 showed a reduction of 4.7%, 14.6%, and 16.2% with slow, habitual, and fast chewing, respectively. A significant difference was observed between slow and fast chewing. Changes in salivary cortisol levels between S1 and S3 showed a reduction of 14.4%, 22.2%, and 25.8% with slow, habitual, and fast chewing, respectively. A significant difference was observed between slow and fast chewing. This study showed that differences in chewing rate affected salivary cortisol levels as a stress indicator, and suggested that the effect on stress release with fast chewing is greater than that with slow chewing.

  14. Combining fast walking training and a step activity monitoring program to improve daily walking activity after stroke: a preliminary study

    PubMed Central

    Danks, Kelly A.; Pohlig, Ryan; Reisman, Darcy S.

    2016-01-01

    Objective To determine preliminary efficacy and to identify baseline characteristics predicting who would benefit most from fast walking training plus a step activity monitoring program (FAST+SAM) compared to fast walking training alone (FAST) in persons with chronic stroke. Design Randomized controlled trial with blinded assessors Setting Outpatient clinical research laboratory Participants 37 individuals greater than 6 months post-stroke. Interventions Subjects were assigned to either FAST which was walking training at their fastest possible speed on the treadmill (30 minutes) and over ground 3 times/week for 12 weeks or FAST plus a step activity monitoring program (FAST+SAM). The step activity monitoring program consisted of daily step monitoring with a StepWatch Activity monitor, goal setting, and identification of barriers to activity and strategies to overcome barriers. Main Outcome Measures Daily step activity metrics (steps/day, time walking/day), walking speed and six minute walk test distance (6MWT). Results There was a significant effect of time for both groups with all outcomes improving from pre to post-training, (all p<0.05). The FAST+SAM was superior to FAST for 6MWT (p=0.018), with a larger increase in the FAST+SAM group. The interventions had differential effectiveness based on baseline step activity. Sequential moderated regression models demonstrated that for subjects with baseline levels of step activity and 6MWT distances that were below the mean, the FAST+SAM intervention was more effective than FAST (1715±1584 vs. 254±933 steps/day, respectively; p<0.05 for overall model and ΔR2 for steps/day and 6MWT). Conclusions The addition of a step activity monitoring program to a fast walking training intervention may be most effective in persons with chronic stroke that have initial low levels of walking endurance and activity. Regardless of baseline performance, the FAST + SAM intervention was more effective for improving walking endurance. PMID:27240430

  15. Competitive code-based fast palmprint identification using a set of cover trees

    NASA Astrophysics Data System (ADS)

    Yue, Feng; Zuo, Wangmeng; Zhang, David; Wang, Kuanquan

    2009-06-01

    A palmprint identification system recognizes a query palmprint image by searching for its nearest neighbor from among all the templates in a database. When applied on a large-scale identification system, it is often necessary to speed up the nearest-neighbor searching process. We use competitive code, which has very fast feature extraction and matching speed, for palmprint identification. To speed up the identification process, we extend the cover tree method and propose to use a set of cover trees to facilitate the fast and accurate nearest-neighbor searching. We can use the cover tree method because, as we show, the angular distance used in competitive code can be decomposed into a set of metrics. Using the Hong Kong PolyU palmprint database (version 2) and a large-scale palmprint database, our experimental results show that the proposed method searches for nearest neighbors faster than brute force searching.

  16. Effect of 48 h Fasting on Autonomic Function, Brain Activity, Cognition, and Mood in Amateur Weight Lifters.

    PubMed

    Solianik, Rima; Sujeta, Artūras; Terentjevienė, Asta; Skurvydas, Albertas

    2016-01-01

    Objectives. The acute fasting-induced cardiovascular autonomic response and its effect on cognition and mood remain debatable. Thus, the main purpose of this study was to estimate the effect of a 48 h, zero-calorie diet on autonomic function, brain activity, cognition, and mood in amateur weight lifters. Methods. Nine participants completed a 48 h, zero-calorie diet program. Cardiovascular autonomic function, resting frontal brain activity, cognitive performance, and mood were evaluated before and after fasting. Results. Fasting decreased ( p < 0.05) weight, heart rate, and systolic blood pressure, whereas no changes were evident regarding any of the measured heart rate variability indices. Fasting decreased ( p < 0.05) the concentration of oxygenated hemoglobin and improved ( p < 0.05) mental flexibility and shifting set, whereas no changes were observed in working memory, visuospatial discrimination, and spatial orientation ability. Fasting also increased ( p < 0.05) anger, whereas other mood states were not affected by it. Conclusions. 48 h fasting resulted in higher parasympathetic activity and decreased resting frontal brain activity, increased anger, and improved prefrontal-cortex-related cognitive functions, such as mental flexibility and set shifting, in amateur weight lifters. In contrast, hippocampus-related cognitive functions were not affected by it.

  17. Effect of 48 h Fasting on Autonomic Function, Brain Activity, Cognition, and Mood in Amateur Weight Lifters

    PubMed Central

    Skurvydas, Albertas

    2016-01-01

    Objectives. The acute fasting-induced cardiovascular autonomic response and its effect on cognition and mood remain debatable. Thus, the main purpose of this study was to estimate the effect of a 48 h, zero-calorie diet on autonomic function, brain activity, cognition, and mood in amateur weight lifters. Methods. Nine participants completed a 48 h, zero-calorie diet program. Cardiovascular autonomic function, resting frontal brain activity, cognitive performance, and mood were evaluated before and after fasting. Results. Fasting decreased (p < 0.05) weight, heart rate, and systolic blood pressure, whereas no changes were evident regarding any of the measured heart rate variability indices. Fasting decreased (p < 0.05) the concentration of oxygenated hemoglobin and improved (p < 0.05) mental flexibility and shifting set, whereas no changes were observed in working memory, visuospatial discrimination, and spatial orientation ability. Fasting also increased (p < 0.05) anger, whereas other mood states were not affected by it. Conclusions. 48 h fasting resulted in higher parasympathetic activity and decreased resting frontal brain activity, increased anger, and improved prefrontal-cortex-related cognitive functions, such as mental flexibility and set shifting, in amateur weight lifters. In contrast, hippocampus-related cognitive functions were not affected by it. PMID:28025637

  18. Application of Fast Dynamic Allan Variance for the Characterization of FOGs-Based Measurement While Drilling.

    PubMed

    Wang, Lu; Zhang, Chunxi; Gao, Shuang; Wang, Tao; Lin, Tie; Li, Xianmu

    2016-12-07

    The stability of a fiber optic gyroscope (FOG) in measurement while drilling (MWD) could vary with time because of changing temperature, high vibration, and sudden power failure. The dynamic Allan variance (DAVAR) is a sliding version of the Allan variance. It is a practical tool that could represent the non-stationary behavior of the gyroscope signal. Since the normal DAVAR takes too long to deal with long time series, a fast DAVAR algorithm has been developed to accelerate the computation speed. However, both the normal DAVAR algorithm and the fast algorithm become invalid for discontinuous time series. What is worse, the FOG-based MWD underground often keeps working for several days; the gyro data collected aboveground is not only very time-consuming, but also sometimes discontinuous in the timeline. In this article, on the basis of the fast algorithm for DAVAR, we make a further advance in the fast algorithm (improved fast DAVAR) to extend the fast DAVAR to discontinuous time series. The improved fast DAVAR and the normal DAVAR are used to responsively characterize two sets of simulation data. The simulation results show that when the length of the time series is short, the improved fast DAVAR saves 78.93% of calculation time. When the length of the time series is long ( 6 × 10 5 samples), the improved fast DAVAR reduces calculation time by 97.09%. Another set of simulation data with missing data is characterized by the improved fast DAVAR. Its simulation results prove that the improved fast DAVAR could successfully deal with discontinuous data. In the end, a vibration experiment with FOGs-based MWD has been implemented to validate the good performance of the improved fast DAVAR. The results of the experience testify that the improved fast DAVAR not only shortens computation time, but could also analyze discontinuous time series.

  19. Application of Fast Dynamic Allan Variance for the Characterization of FOGs-Based Measurement While Drilling

    PubMed Central

    Wang, Lu; Zhang, Chunxi; Gao, Shuang; Wang, Tao; Lin, Tie; Li, Xianmu

    2016-01-01

    The stability of a fiber optic gyroscope (FOG) in measurement while drilling (MWD) could vary with time because of changing temperature, high vibration, and sudden power failure. The dynamic Allan variance (DAVAR) is a sliding version of the Allan variance. It is a practical tool that could represent the non-stationary behavior of the gyroscope signal. Since the normal DAVAR takes too long to deal with long time series, a fast DAVAR algorithm has been developed to accelerate the computation speed. However, both the normal DAVAR algorithm and the fast algorithm become invalid for discontinuous time series. What is worse, the FOG-based MWD underground often keeps working for several days; the gyro data collected aboveground is not only very time-consuming, but also sometimes discontinuous in the timeline. In this article, on the basis of the fast algorithm for DAVAR, we make a further advance in the fast algorithm (improved fast DAVAR) to extend the fast DAVAR to discontinuous time series. The improved fast DAVAR and the normal DAVAR are used to responsively characterize two sets of simulation data. The simulation results show that when the length of the time series is short, the improved fast DAVAR saves 78.93% of calculation time. When the length of the time series is long (6×105 samples), the improved fast DAVAR reduces calculation time by 97.09%. Another set of simulation data with missing data is characterized by the improved fast DAVAR. Its simulation results prove that the improved fast DAVAR could successfully deal with discontinuous data. In the end, a vibration experiment with FOGs-based MWD has been implemented to validate the good performance of the improved fast DAVAR. The results of the experience testify that the improved fast DAVAR not only shortens computation time, but could also analyze discontinuous time series. PMID:27941600

  20. Simultaneous Retrieval of Temperature, Water Vapor and Ozone Atmospheric Profiles from IASI: Compression, De-noising, First Guess Retrieval and Inversion Algorithms

    NASA Technical Reports Server (NTRS)

    Aires, F.; Rossow, W. B.; Scott, N. A.; Chedin, A.; Hansen, James E. (Technical Monitor)

    2001-01-01

    A fast temperature water vapor and ozone atmospheric profile retrieval algorithm is developed for the high spectral resolution Infrared Atmospheric Sounding Interferometer (IASI) space-borne instrument. Compression and de-noising of IASI observations are performed using Principal Component Analysis. This preprocessing methodology also allows, for a fast pattern recognition in a climatological data set to obtain a first guess. Then, a neural network using first guess information is developed to retrieve simultaneously temperature, water vapor and ozone atmospheric profiles. The performance of the resulting fast and accurate inverse model is evaluated with a large diversified data set of radiosondes atmospheres including rare events.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhattacharyya, M.H.; Larsen, R.P.; Oldham, R.D.

    The fraction of plutonium absorbed after oral administration of Pu(VI) to 24-h-fasted mice was 19 X 10(-4), 13-fold higher than in fed mice, 1.4 X 10(-4). We have investigated the relevance of the high gastrointestinal (GI) absorption value for the 24-h-fasted animals in setting drinking water standards for humans. When fasting was initiated at the beginning of the active phase of the mouse's daily activity cycle (when they would normally eat), plutonium GI absorption rose from 2.8 X 10(-4) at zero-time to a level typical of the 24-h-fasted mouse after only 2 h of fasting. In contrast, in mice allowedmore » to eat for 4 h into their active phase prior to initiation of the fast (meal-fed mice), 8 h of fasting were required before GI absorption rose to a level similar to that of the 24-h-fasted mouse. The fraction of plutonium retained after gavage administration of Pu(VI) to 1-day-old rats was 74 X 10(-4), 70-fold higher than the value for fed adults. Retention after GI absorption in neonates remained 30- to 70-fold higher than in adults until weaning. One week after weaning, the fraction absorbed and retained by fed weanling rats was the same as that for fed adults, 1 X 10(-4). Drinking water standards for plutonium have been set based on GI absorption values for fed adult animals. The 10- to 100-fold increases in plutonium absorption in young and fasted animals reported by ourselves and others, and the rapid rise to fasted levels of absorption at the start of the animal's active phase, indicate that consideration should be given to elevated levels of plutonium absorption in young and fasted individuals.« less

  2. Rank estimation and the multivariate analysis of in vivo fast-scan cyclic voltammetric data

    PubMed Central

    Keithley, Richard B.; Carelli, Regina M.; Wightman, R. Mark

    2010-01-01

    Principal component regression has been used in the past to separate current contributions from different neuromodulators measured with in vivo fast-scan cyclic voltammetry. Traditionally, a percent cumulative variance approach has been used to determine the rank of the training set voltammetric matrix during model development, however this approach suffers from several disadvantages including the use of arbitrary percentages and the requirement of extreme precision of training sets. Here we propose that Malinowski’s F-test, a method based on a statistical analysis of the variance contained within the training set, can be used to improve factor selection for the analysis of in vivo fast-scan cyclic voltammetric data. These two methods of rank estimation were compared at all steps in the calibration protocol including the number of principal components retained, overall noise levels, model validation as determined using a residual analysis procedure, and predicted concentration information. By analyzing 119 training sets from two different laboratories amassed over several years, we were able to gain insight into the heterogeneity of in vivo fast-scan cyclic voltammetric data and study how differences in factor selection propagate throughout the entire principal component regression analysis procedure. Visualizing cyclic voltammetric representations of the data contained in the retained and discarded principal components showed that using Malinowski’s F-test for rank estimation of in vivo training sets allowed for noise to be more accurately removed. Malinowski’s F-test also improved the robustness of our criterion for judging multivariate model validity, even though signal-to-noise ratios of the data varied. In addition, pH change was the majority noise carrier of in vivo training sets while dopamine prediction was more sensitive to noise. PMID:20527815

  3. Perception of Hearing Aid-Processed Speech in Individuals with Late-Onset Auditory Neuropathy Spectrum Disorder.

    PubMed

    Mathai, Jijo Pottackal; Appu, Sabarish

    2015-01-01

    Auditory neuropathy spectrum disorder (ANSD) is a form of sensorineural hearing loss, causing severe deficits in speech perception. The perceptual problems of individuals with ANSD were attributed to their temporal processing impairment rather than to reduced audibility. This rendered their rehabilitation difficult using hearing aids. Although hearing aids can restore audibility, compression circuits in a hearing aid might distort the temporal modulations of speech, causing poor aided performance. Therefore, hearing aid settings that preserve the temporal modulations of speech might be an effective way to improve speech perception in ANSD. The purpose of the study was to investigate the perception of hearing aid-processed speech in individuals with late-onset ANSD. A repeated measures design was used to study the effect of various compression time settings on speech perception and perceived quality. Seventeen individuals with late-onset ANSD within the age range of 20-35 yr participated in the study. The word recognition scores (WRSs) and quality judgment of phonemically balanced words, processed using four different compression settings of a hearing aid (slow, medium, fast, and linear), were evaluated. The modulation spectra of hearing aid-processed stimuli were estimated to probe the effect of amplification on the temporal envelope of speech. Repeated measures analysis of variance and post hoc Bonferroni's pairwise comparisons were used to analyze the word recognition performance and quality judgment. The comparison between unprocessed and all four hearing aid-processed stimuli showed significantly higher perception using the former stimuli. Even though perception of words processed using slow compression time settings of the hearing aids were significantly higher than the fast one, their difference was only 4%. In addition, there were no significant differences in perception between any other hearing aid-processed stimuli. Analysis of the temporal envelope of hearing aid-processed stimuli revealed minimal changes in the temporal envelope across the four hearing aid settings. In terms of quality, the highest number of individuals preferred stimuli processed using slow compression time settings. Individuals who preferred medium ones followed this. However, none of the individuals preferred fast compression time settings. Analysis of quality judgment showed that slow, medium, and linear settings presented significantly higher preference scores than the fast compression setting. Individuals with ANSD showed no marked difference in perception of speech that was processed using the four different hearing aid settings. However, significantly higher preference, in terms of quality, was found for stimuli processed using slow, medium, and linear settings over the fast one. Therefore, whenever hearing aids are recommended for ANSD, those having slow compression time settings or linear amplification may be chosen over the fast (syllabic compression) one. In addition, WRSs obtained using hearing aid-processed stimuli were remarkably poorer than unprocessed stimuli. This shows that processing of speech through hearing aids might have caused a large reduction of performance in individuals with ANSD. However, further evaluation is needed using individually programmed hearing aids rather than hearing aid-processed stimuli. American Academy of Audiology.

  4. Chemical structure-based predictive model for methanogenic anaerobic biodegradation potential.

    PubMed

    Meylan, William; Boethling, Robert; Aronson, Dallas; Howard, Philip; Tunkel, Jay

    2007-09-01

    Many screening-level models exist for predicting aerobic biodegradation potential from chemical structure, but anaerobic biodegradation generally has been ignored by modelers. We used a fragment contribution approach to develop a model for predicting biodegradation potential under methanogenic anaerobic conditions. The new model has 37 fragments (substructures) and classifies a substance as either fast or slow, relative to the potential to be biodegraded in the "serum bottle" anaerobic biodegradation screening test (Organization for Economic Cooperation and Development Guideline 311). The model correctly classified 90, 77, and 91% of the chemicals in the training set (n = 169) and two independent validation sets (n = 35 and 23), respectively. Accuracy of predictions of fast and slow degradation was equal for training-set chemicals, but fast-degradation predictions were less accurate than slow-degradation predictions for the validation sets. Analysis of the signs of the fragment coefficients for this and the other (aerobic) Biowin models suggests that in the context of simple group contribution models, the majority of positive and negative structural influences on ultimate degradation are the same for aerobic and methanogenic anaerobic biodegradation.

  5. A fast bottom-up algorithm for computing the cut sets of noncoherent fault trees

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corynen, G.C.

    1987-11-01

    An efficient procedure for finding the cut sets of large fault trees has been developed. Designed to address coherent or noncoherent systems, dependent events, shared or common-cause events, the method - called SHORTCUT - is based on a fast algorithm for transforming a noncoherent tree into a quasi-coherent tree (COHERE), and on a new algorithm for reducing cut sets (SUBSET). To assure sufficient clarity and precision, the procedure is discussed in the language of simple sets, which is also developed in this report. Although the new method has not yet been fully implemented on the computer, we report theoretical worst-casemore » estimates of its computational complexity. 12 refs., 10 figs.« less

  6. Single-sided mobile NMR apparatus using the transverse flux of a single permanent magnet.

    PubMed

    Chang, Wei-Hao; Chen, Jyh-Horng; Hwang, Lian-Pin

    2010-01-01

    This study presents a simple design for a mobile, single-sided nuclear magnetic resonance (NMR) apparatus which uses the magnetic flux parallel to the magnetization direction of a single, disc-shaped permanent magnet polarized in radial direction. The stray magnetic field above the magnet is approximately parallel to the magnetization direction of the magnet and is utilized as the B(0) magnetic field of the apparatus. The apparatus weighs 1.8 kg, has a compact structure and can be held in one's palm. The apparatus generates a B(0) field strength of about 0.279 T at the center of apparatus surface and can acquire a clear Hahn echo signal of a pencil eraser block lying on the RF coil in one shot. Moreover, a strong static magnetic field gradient exists in the direction perpendicular to the apparatus surface. The strength of the static magnetic field gradient near the center of the apparatus surface is about 10.2 T/m; one-dimensional imaging of thin objects and liquid self-diffusion coefficient measurements can be performed therein. The available spatial resolution of the one-dimensional imaging experiments using a 5 x 5 mm horizontal sample area is about 200 mum. Several nondestructive inspection applications of the apparatus, including distinguishing between polyethylene grains of different densities, characterizing epoxy putties of distinct set times and evaluating the fat content percentages of milk powders, are also demonstrated. Compared with many previously published designs, the proposed design bears a simple structure and generates a B(0) magnetic field parallel to the apparatus surface, simplifying apparatus construction and simultaneously rendering the selection of the radiofrequency coil relatively flexible.

  7. Spherical Demons: Fast Surface Registration

    PubMed Central

    Yeo, B.T. Thomas; Sabuncu, Mert; Vercauteren, Tom; Ayache, Nicholas; Fischl, Bruce; Golland, Polina

    2009-01-01

    We present the fast Spherical Demons algorithm for registering two spherical images. By exploiting spherical vector spline interpolation theory, we show that a large class of regularizers for the modified demons objective function can be efficiently implemented on the sphere using convolution. Based on the one parameter subgroups of diffeomorphisms, the resulting registration is diffeomorphic and fast – registration of two cortical mesh models with more than 100k nodes takes less than 5 minutes, comparable to the fastest surface registration algorithms. Moreover, the accuracy of our method compares favorably to the popular FreeSurfer registration algorithm. We validate the technique in two different settings: (1) parcellation in a set of in-vivo cortical surfaces and (2) Brodmann area localization in ex-vivo cortical surfaces. PMID:18979813

  8. Spherical demons: fast surface registration.

    PubMed

    Yeo, B T Thomas; Sabuncu, Mert; Vercauteren, Tom; Ayache, Nicholas; Fischl, Bruce; Golland, Polina

    2008-01-01

    We present the fast Spherical Demons algorithm for registering two spherical images. By exploiting spherical vector spline interpolation theory, we show that a large class of regularizers for the modified demons objective function can be efficiently implemented on the sphere using convolution. Based on the one parameter subgroups of diffeomorphisms, the resulting registration is diffeomorphic and fast - registration of two cortical mesh models with more than 100k nodes takes less than 5 minutes, comparable to the fastest surface registration algorithms. Moreover, the accuracy of our method compares favorably to the popular FreeSurfer registration algorithm. We validate the technique in two different settings: (1) parcellation in a set of in-vivo cortical surfaces and (2) Brodmann area localization in ex-vivo cortical surfaces.

  9. Cost-Reduced M587 Electronic Time Fuze: Root Cause Analysis of July 1979 Early Bursts

    DTIC Science & Technology

    1981-04-01

    capacitor during gunfire, coupled with an intermit - tent wire bond (which opens during setback and then closes again) can defeat the initialization circuit...is calibrated, (c) the set time is checked out in fast time to verify that the setting has actually been achieved, and (d) the setter visually com...insensitive to supply voltage. One of the reasons for choosing the twin-T design was because it was possible to preclude fail- fast failure modes. The

  10. Simplified technique for orbital prosthesis fabrication: a clinical report.

    PubMed

    Veerareddy, Chandrika; Nair, K Chandrasekharan; Reddy, G Ramaswamy

    2012-10-01

    Loss of orbital content can cause functional impairment, disfigurement of the face, and psychological distress. Rehabilitation of an orbital defect is a complex task, and if reconstruction by plastic surgery is not possible or not desired by the patient, the defect can be rehabilitated by an orbital prosthesis. The prosthetic rehabilitation in such cases depends on the precisely retained, user-friendly removable maxillofacial prosthesis. Many times, making an impression of the orbital area with an accurate record of surface details can be a difficult procedure. The critical areas are making a facial moulage, mold preparation, and attaching the retention device, particularly when eyeglass frames are used. This case focuses on these hindrance factors. A simple basket was used for the impression tray to obtain the facial moulage. A putty mold was used, and attachment of the prosthesis to a retention device was accomplished with positional distance. This method proves to be an economical and simple way of making an orbital prosthesis. © 2012 by the American College of Prosthodontists.

  11. Spectrometric investigation of the weathering process affecting historical glasses of León Cathedral, Spain

    NASA Astrophysics Data System (ADS)

    Castro, M. A.; Pereira, F. J.; Aller, A. J.; Littlejohn, D.

    2014-12-01

    Atmospheric pollution plays important roles in the weathering of the historical buildings and glass windows. Samples of white powdered weathering products, recovered during restoration of the stained-glass windows of León Cathedral in Spain, were characterised using a combination of scanning electron microscopy (SEM) with energy dispersive-X ray spectrometry (ED-XRS), Fourier transform-infrared (FT-IR) spectroscopy and Raman spectrometry. The presence of sulphates, and to a lesser extent carbonates, in the white powdered product is clear indication of the participation of atmospheric acidifying gases, particularly SOx, in the weathering process. It is interesting to note that there was no indication of the participation of NOx gases. There was, however, evidence that the putty and mortar used to seal/join the glasses were major sources of the weathering products. In this way, this study suggests sealants more resistant to oxidation, such as silicone- and zirconia-based materials, should be considered for repairing glass windows in historic buildings to avoid exacerbating degradation.

  12. Lead toxicity and metabolism in animals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neathery, M.W.; Miller, W.J.

    1976-02-16

    The main biological interest in lead is its toxicity. Among farm animals, ruminants are most often affected, followed by horses, poultry and swine. Although information is sparse, inhalation of airborne lead is of much less practical importance than ingestion. Most commonly, acute lead poisoning in cattle arises from eating flaking paint, motor oil, linoleum and certain types of grease and putty. Ingestion of lead is one of the most frequently reported causes of acute poisoning, especially in cattle. General clinical symptoms of lead toxicity in farm animals include anemia, depressed appearance, anorexia and muscular incoordination. A special effect in horsesmore » is a laryngeal paralysis which produces an obstruction in the air passage causing them to roar. Lead absorption from the intestine is relatively low (less than 2%), and accumulation occurs mostly in the bone, liver and kidney. Very little is secreted into the milk or concentrated into the muscles. However, lead easily passes the placental barrier, causing serious damage and sometimes death to the fetus. 48 references, 2 tables.« less

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    May, C.A.; Breitigam, W.; Bauer, R.S.

    The laminates that are used to prepare advanced composite parts generally require curing at high temperature and pressure, and their raw material shelf lives are limited. The epoxy resin systems that the authors describe here offer the potential of extended shelf life while curing at relatively low temperatures with a method the authors call rapid thermoset processing (RTP). A laminate is formed by stacking the prepreg in a pre-determined manner as required by the end product configuration. The prepreg is then bagged by placing it in a sealed envelope of a heat-resistant film, which is subsequently bonded to a metalmore » surface (the tool) with a heat-resistant vacuum bag putty. The bag has an access hole through which vacuum can be applied to the prepreg stack, facilitating removal of air and other volatiles. This assembly is then heated under vacuum and pressure in an autoclave, the resin melts, and any excess air or volatile matter bleeds from the configuration, resulting in the required dense, void-free laminate.« less

  14. [Fast-track treatment--second revolution of colorectal surgery].

    PubMed

    Kellokumpu, Ilmo

    2012-01-01

    The fast-track treatment model can be regarded as the second revolution of colorectal surgery after the introduction of laparoscopic surgery. In the gastro-surgical unit of the Central Hospital of Central Finland, results equivalent to international studies in colorectal surgery have been achieved by using fast-track model. In a study setting, this treatment model has resulted in significant decrease of total treatment costs and speeded up discharge of the patients from the hospital. The fast-track treatment model requires both a motivated, trained medical team and a motivated patient.

  15. Subjective and Objective Effects of Fast and Slow Compression on the Perception of Reverberant Speech in Listeners with Hearing Loss

    ERIC Educational Resources Information Center

    Shi, Lu-Feng; Doherty, Karen A.

    2008-01-01

    Purpose: The purpose of the current study was to assess the effect of fast and slow attack/release times (ATs/RTs) on aided perception of reverberant speech in quiet. Method: Thirty listeners with mild-to-moderate sensorineural hearing loss were tested monaurally with a commercial hearing aid programmed in 3 AT/RT settings: linear, fast (AT = 9…

  16. eFAST for the diagnosis of a perioperative complication during percutaneous nephrolithotomy.

    PubMed

    Sharma, Achyut; Bhattarai, Prajjwal; Sharma, Apurb

    2018-04-03

    A 29-year-old patient with normal preanesthetic evaluation was planned for percutaneous nephrolithotomy (PCNL) for right nephrolithiasis with right pyelolithiasis. Surgery was performed under general anesthesia with endotracheal intubation with muscle relaxation. At the conclusion of surgery, when the patient was turned over to supine position, tense abdomen was noted. Immediately extended focused assessment with sonography in trauma (eFAST) was done in which both right and left quadrants of abdomen including pericardial and suprapubic region, right and left thoracic, and both lung basis were examined. Fluid collection was seen in Morison's pouch which was drained by the urologist under real-time ultrasonography guidance by anesthesiologist. Distension of abdomen subsequently subsided and patient had normal vitals. Trachea was extubated and patient shifted to post-operative ward. eFAST and FAST scans are routine procedures in the rapid assessment of trauma victims in emergency settings. The fluid extravasation during a routine PCNL procedure may lead to abdominal compartment syndrome. This case demonstrated that use of eFAST rapidly detected abdominal collection and ruled out life-threatening conditions such as hemothorax and pneumothorax and prevented abdominal compartment syndrome. Our case is only an example that potentially lethal conditions like these may be encountered in the perioperative setting and the knowledge of eFAST scan may be of great help.

  17. CANCER CONTROL AND POPULATION SCIENCES FAST STATS

    EPA Science Inventory

    Fast Stats links to tables, charts, and graphs of cancer statistics for all major cancer sites by age, sex, race, and geographic area. The statistics include incidence, mortality, prevalence, and the probability of developing or dying from cancer. A large set of statistics is ava...

  18. Dynamic topography in subduction zones: insights from laboratory models

    NASA Astrophysics Data System (ADS)

    Bajolet, Flora; Faccenna, Claudio; Funiciello, Francesca

    2014-05-01

    The topography in subduction zones can exhibit very complex patterns due to the variety of forces operating this setting. If we can deduce the theoretical isostatic value from density structure of the lithosphere, the effect of flexural bending and the dynamic component of topography are difficult to quantify. In this work, we attempt to measure and analyze the topography of the overriding plate during subduction compared to a pure shortening setting. We use analog models where the lithospheres are modeled by thin-sheet layers of silicone putty lying on low-viscosity syrup (asthenosphere). The model is shorten by a piston pushing an oceanic plate while a continental plate including a weak zone to localize the deformation is fixed. In one type of experiments, the oceanic plate bends and subducts underneath the continental one; in a second type the two plates are in contact without any trench, and thus simply shorten. The topography evolution is monitored with a laser-scanner. In the shortening model, the elevation increases progressively, especially in the weak zone, and is consistent with expected isostatic values. In the subduction model, the topography is characterized, from the piston to the back-wall, by a low elevation of the dense oceanic plate, a flexural bulge, the trench forming a deep depression, the highly elevated weak zone, and the continental upper plate of intermediate elevation. The topography of the upper plate is consistent with isostatic values for very early stages, but exhibits lower elevations than expected for later stages. For a same amount of shortening of the continental plate, the thickening is the same and the plate should have the same elevation in both types of models. However, comparing the topography at 20, 29 and 39% of shortening, we found that the weak zone is 0.4 to 0.6 mm lower when there is an active subduction. Theses values correspond to 2.6 to 4 km in nature. Although theses values are high, there are of the same order as dynamic topography and could represent the dynamic effect of the slab sinking into the asthenosphere and lowering the elevation of the upper plate.

  19. Fast Food Consumption Pattern and Its Association with Overweight Among High School Boys in Mangalore City of Southern India

    PubMed Central

    Nelliyanil, Maria; Rai, Sharada; Y.P., Raghavendra Babu; Kotian, Shashidhar M.; Ghosh, Tanima; Singh, Manisha

    2015-01-01

    Context Fast foods are quite popular among children owing to taste, appearance and hype created by mass media. However, the increased incidence of lifestyle disorders seen now-a-days at an early age could be attributed to fast foods. Aim This study was done to assess the awareness of health hazards, consumption pattern of fast foods and to find out its association with overweight among high school students. Settings and Design This cross-sectional study was done among boys of 3 private schools in Mangalore city in March 2012. Materials and Methods Data was collected using a semi-structured self-administered questionnaire. Statistical Analysis Chi-square test, one-way ANOVA and binary logistic regression analysis was used for analysis. P-value ≤ 0.05 was considered as statistically significant association. Results Mean age of boys was 13.5±0.9 years. Out of 300 participants, 41(13.7%) were overweight and 8 (2.7%) were obese. 292(97.3%) were fast food users of which 42(14.4%) consumed it every day. Majority of participants were introduced to fast foods through television commercials 193(64.3%). 73(57%) developed this habit as they were bored with home food. Awareness of harmful effects of fast food consumption was known to 186(62%) students and this was found to be associated with the perceived need to control its usage (p<0.001). Parental consumption of fast foods was found to influence fast food consumption among children (p=0.024). As many as 68(22.7%) and 206(68.7%) children were not eating vegetables and fruits respectively every day. Increased frequency of fast food consumption in a week was found to be associated with overweight or obesity among children after adjusting the effects of confounders (p=0.003). Conclusion Awareness on health hazards of fast foods needs to be taught at schools so as to minimize its consumption. Parents have to set an example themselves by not eating fast foods and improving home food to support discouragement of fast foods. This would minimize life style disorders among children to a greater extent. PMID:26155501

  20. Efficient Kriging via Fast Matrix-Vector Products

    NASA Technical Reports Server (NTRS)

    Memarsadeghi, Nargess; Raykar, Vikas C.; Duraiswami, Ramani; Mount, David M.

    2008-01-01

    Interpolating scattered data points is a problem of wide ranging interest. Ordinary kriging is an optimal scattered data estimator, widely used in geosciences and remote sensing. A generalized version of this technique, called cokriging, can be used for image fusion of remotely sensed data. However, it is computationally very expensive for large data sets. We demonstrate the time efficiency and accuracy of approximating ordinary kriging through the use of fast matrixvector products combined with iterative methods. We used methods based on the fast Multipole methods and nearest neighbor searching techniques for implementations of the fast matrix-vector products.

  1. Fast packet switch architectures for broadband integrated services digital networks

    NASA Technical Reports Server (NTRS)

    Tobagi, Fouad A.

    1990-01-01

    Background information on networking and switching is provided, and the various architectures that have been considered for fast packet switches are described. The focus is solely on switches designed to be implemented electronically. A set of definitions and a brief description of the functionality required of fast packet switches are given. Three basic types of packet switches are identified: the shared-memory, shared-medium, and space-division types. Each of these is described, and examples are given.

  2. A pipette-based calibration system for fast-scan cyclic voltammetry with fast response times.

    PubMed

    Ramsson, Eric S

    2016-01-01

    Fast-scan cyclic voltammetry (FSCV) is an electrochemical technique that utilizes the oxidation and/or reduction of an analyte of interest to infer rapid changes in concentrations. In order to calibrate the resulting oxidative or reductive current, known concentrations of an analyte must be introduced under controlled settings. Here, I describe a simple and cost-effective method, using a Petri dish and pipettes, for the calibration of carbon fiber microelectrodes (CFMs) using FSCV.

  3. A web-based study of the relationship of duration of insulin pump infusion set use and fasting blood glucose level in adults with type 1 diabetes.

    PubMed

    Sampson Perrin, Alysa J; Guzzetta, Russell C; Miller, Kellee M; Foster, Nicole C; Lee, Anna; Lee, Joyce M; Block, Jennifer M; Beck, Roy W

    2015-05-01

    To evaluate the impact of infusion set use duration on glycemic control, we conducted an Internet-based study using the T1D Exchange's online patient community, Glu ( myGlu.org ). For 14 days, 243 electronically consented adults with type 1 diabetes (T1D) entered online that day's fasting blood glucose (FBG) level, the prior day's total daily insulin (TDI) dose, and whether the infusion set was changed. Mean duration of infusion set use was 3.0 days. Mean FBG level was higher with each successive day of infusion set use, increasing from 126 mg/dL on Day 1 to 133 mg/dL on Day 3 to 147 mg/dL on Day 5 (P<0.001). TDI dose did not vary with increased duration of infusion set use. Internet-based data collection was used to rapidly conduct the study at low cost. The results indicate that FBG levels increase with each additional day of insulin pump infusion set use.

  4. Family dinner frequency, settings and sources, and body weight in US adults.

    PubMed

    Sobal, Jeffery; Hanson, Karla

    2014-07-01

    Contemporary families and food systems are both becoming more dynamic and complex, and current associations between adult family meals and body mass index (BMI) are not well understood. This investigation took a new approach by examining diverse settings and sources of food for family dinners in relationship to BMI in a cross-sectional nationally representative survey of 360 US adults age 18-85 living with family members. In this sample, 89% of adults ate family dinners at least 5 days per week and almost all ate family dinners cooked and eaten at home. About half of these adults also ate family dinners at restaurants, fast food places, or ate takeout food at home, and less common were family dinners at homes of relatives or friends. Family dinners eaten at fast food places, but not other settings or sources, were significantly associated with higher BMI. Overall, adult family dinners were commonplace, usually involved home cooking, and when at fast food places may be related with higher adult body weights. Copyright © 2014. Published by Elsevier Ltd.

  5. Optimization-Based Calibration of FAST.Farm Parameters Against SOWFA: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moreira, Paula D; Annoni, Jennifer; Jonkman, Jason

    2018-01-04

    FAST.Farm is a medium-delity wind farm modeling tool that can be used to assess power and loads contributions of wind turbines in a wind farm. The objective of this paper is to undertake a calibration procedure to set the user parameters of FAST.Farm to accurately represent results from large-eddy simulations. The results provide an in- depth analysis of the comparison of FAST.Farm and large-eddy simulations before and after calibration. The comparison of FAST.Farm and large-eddy simulation results are presented with respect to streamwise and radial velocity components as well as wake-meandering statistics (mean and standard deviation) in the lateral andmore » vertical directions under different atmospheric and turbine operating conditions.« less

  6. Neighborhood fast food restaurants and fast food consumption: A national study

    PubMed Central

    2011-01-01

    Background Recent studies suggest that neighborhood fast food restaurant availability is related to greater obesity, yet few studies have investigated whether neighborhood fast food restaurant availability promotes fast food consumption. Our aim was to estimate the effect of neighborhood fast food availability on frequency of fast food consumption in a national sample of young adults, a population at high risk for obesity. Methods We used national data from U.S. young adults enrolled in wave III (2001-02; ages 18-28) of the National Longitudinal Study of Adolescent Health (n = 13,150). Urbanicity-stratified multivariate negative binomial regression models were used to examine cross-sectional associations between neighborhood fast food availability and individual-level self-reported fast food consumption frequency, controlling for individual and neighborhood characteristics. Results In adjusted analysis, fast food availability was not associated with weekly frequency of fast food consumption in non-urban or low- or high-density urban areas. Conclusions Policies aiming to reduce neighborhood availability as a means to reduce fast food consumption among young adults may be unsuccessful. Consideration of fast food outlets near school or workplace locations, factors specific to more or less urban settings, and the role of individual lifestyle attitudes and preferences are needed in future research. PMID:21740571

  7. Fast-food menu offerings vary in dietary quality, but are consistently poor

    PubMed Central

    Kirkpatrick, Sharon I; Reedy, Jill; Kahle, Lisa L; Harris, Jennifer L; Ohri-Vachaspati, Punam; Krebs-Smith, Susan M

    2013-01-01

    Objective To evaluate five popular fast-food chains’ menus in relation to dietary guidance. Design Menus posted on chains’ websites were coded using the Food and Nutrient Database for Dietary Studies and MyPyramid Equivalents Database to enable Healthy Eating Index-2005 (HEI-2005) scores to be assigned. Dollar or value and kids’ menus and sets of items promoted as healthy or nutritious were also assessed. Setting Five popular fast-food chains in the USA. Subjects Not applicable. Results Full menus scored lower than 50 out of 100 possible points on the HEI-2005. Scores for Total Fruit, Whole Grains and Sodium were particularly dismal. Compared with full menus, scores on dollar or value menus were 3 points higher on average, whereas kids’ menus scored 10 points higher on average. Three chains marketed subsets of items as healthy or nutritious; these scored 17 points higher on average compared with the full menus. No menu or subset of menu items received a score higher than 72 out of 100 points. Conclusions The poor quality of fast-food menus is a concern in light of increasing away-from-home eating, aggressive marketing to children and minorities, and the tendency for fast-food restaurants to be located in low-income and minority areas. The addition of fruits, vegetables and legumes; replacement of refined with whole grains; and reformulation of offerings high in sodium, solid fats and added sugars are potential strategies to improve fast-food offerings. The HEI may be a useful metric for ongoing monitoring of fast-food menus. PMID:23317511

  8. Common and Specific Factors Approaches to Home-Based Treatment: I-FAST and MST

    ERIC Educational Resources Information Center

    Lee, Mo Yee; Greene, Gilbert J.; Fraser, J. Scott; Edwards, Shivani G.; Grove, David; Solovey, Andrew D.; Scott, Pamela

    2013-01-01

    Objectives: This study examined the treatment outcomes of integrated families and systems treatment (I-FAST), a moderated common factors approach, in reference to multisystemic therapy (MST), an established specific factor approach, for treating at risk children and adolescents and their families in an intensive community-based setting. Method:…

  9. Abel inversion using fast Fourier transforms.

    PubMed

    Kalal, M; Nugent, K A

    1988-05-15

    A fast Fourier transform based Abel inversion technique is proposed. The method is faster than previously used techniques, potentially very accurate (even for a relatively small number of points), and capable of handling large data sets. The technique is discussed in the context of its use with 2-D digital interferogram analysis algorithms. Several examples are given.

  10. Application of activation methods on the Dubna experimental transmutation set-ups.

    PubMed

    Stoulos, S; Fragopoulou, M; Adloff, J C; Debeauvais, M; Brandt, R; Westmeier, W; Krivopustov, M; Sosnin, A; Papastefanou, C; Zamani, M; Manolopoulou, M

    2003-02-01

    High spallation neutron fluxes were produced by irradiating massive heavy targets with proton beams in the GeV range. The experiments were performed at the Dubna High Energy Laboratory using the nuclotron accelerator. Two different experimental set-ups were used to produce neutron spectra convenient for transmutation of radioactive waste by (n,x) reactions. By a theoretical analysis neutron spectra can be reproduced from activation measurements. Thermal-epithermal and fast-super-fast neutron fluxes were estimated using the 197Au, 238U (n,gamma) and (n,2n) reactions, respectively. Depleted uranium transmutation rates were also studied in both experiments.

  11. Robust and fast-converging level set method for side-scan sonar image segmentation

    NASA Astrophysics Data System (ADS)

    Liu, Yan; Li, Qingwu; Huo, Guanying

    2017-11-01

    A robust and fast-converging level set method is proposed for side-scan sonar (SSS) image segmentation. First, the noise in each sonar image is removed using the adaptive nonlinear complex diffusion filter. Second, k-means clustering is used to obtain the initial presegmentation image from the denoised image, and then the distance maps of the initial contours are reinitialized to guarantee the accuracy of the numerical calculation used in the level set evolution. Finally, the satisfactory segmentation is achieved using a robust variational level set model, where the evolution control parameters are generated by the presegmentation. The proposed method is successfully applied to both synthetic image with speckle noise and real SSS images. Experimental results show that the proposed method needs much less iteration and therefore is much faster than the fuzzy local information c-means clustering method, the level set method using a gamma observation model, and the enhanced region-scalable fitting method. Moreover, the proposed method can usually obtain more accurate segmentation results compared with other methods.

  12. Fast and efficient indexing approach for object recognition

    NASA Astrophysics Data System (ADS)

    Hefnawy, Alaa; Mashali, Samia A.; Rashwan, Mohsen; Fikri, Magdi

    1999-08-01

    This paper introduces a fast and efficient indexing approach for both 2D and 3D model-based object recognition in the presence of rotation, translation, and scale variations of objects. The indexing entries are computed after preprocessing the data by Haar wavelet decomposition. The scheme is based on a unified image feature detection approach based on Zernike moments. A set of low level features, e.g. high precision edges, gray level corners, are estimated by a set of orthogonal Zernike moments, calculated locally around every image point. A high dimensional, highly descriptive indexing entries are then calculated based on the correlation of these local features and employed for fast access to the model database to generate hypotheses. A list of the most candidate models is then presented by evaluating the hypotheses. Experimental results are included to demonstrate the effectiveness of the proposed indexing approach.

  13. Evaluating Fast Maximum Likelihood-Based Phylogenetic Programs Using Empirical Phylogenomic Data Sets

    PubMed Central

    Zhou, Xiaofan; Shen, Xing-Xing; Hittinger, Chris Todd

    2018-01-01

    Abstract The sizes of the data matrices assembled to resolve branches of the tree of life have increased dramatically, motivating the development of programs for fast, yet accurate, inference. For example, several different fast programs have been developed in the very popular maximum likelihood framework, including RAxML/ExaML, PhyML, IQ-TREE, and FastTree. Although these programs are widely used, a systematic evaluation and comparison of their performance using empirical genome-scale data matrices has so far been lacking. To address this question, we evaluated these four programs on 19 empirical phylogenomic data sets with hundreds to thousands of genes and up to 200 taxa with respect to likelihood maximization, tree topology, and computational speed. For single-gene tree inference, we found that the more exhaustive and slower strategies (ten searches per alignment) outperformed faster strategies (one tree search per alignment) using RAxML, PhyML, or IQ-TREE. Interestingly, single-gene trees inferred by the three programs yielded comparable coalescent-based species tree estimations. For concatenation-based species tree inference, IQ-TREE consistently achieved the best-observed likelihoods for all data sets, and RAxML/ExaML was a close second. In contrast, PhyML often failed to complete concatenation-based analyses, whereas FastTree was the fastest but generated lower likelihood values and more dissimilar tree topologies in both types of analyses. Finally, data matrix properties, such as the number of taxa and the strength of phylogenetic signal, sometimes substantially influenced the programs’ relative performance. Our results provide real-world gene and species tree phylogenetic inference benchmarks to inform the design and execution of large-scale phylogenomic data analyses. PMID:29177474

  14. biobambam: tools for read pair collation based algorithms on BAM files

    PubMed Central

    2014-01-01

    Background Sequence alignment data is often ordered by coordinate (id of the reference sequence plus position on the sequence where the fragment was mapped) when stored in BAM files, as this simplifies the extraction of variants between the mapped data and the reference or of variants within the mapped data. In this order paired reads are usually separated in the file, which complicates some other applications like duplicate marking or conversion to the FastQ format which require to access the full information of the pairs. Results In this paper we introduce biobambam, a set of tools based on the efficient collation of alignments in BAM files by read name. The employed collation algorithm avoids time and space consuming sorting of alignments by read name where this is possible without using more than a specified amount of main memory. Using this algorithm tasks like duplicate marking in BAM files and conversion of BAM files to the FastQ format can be performed very efficiently with limited resources. We also make the collation algorithm available in the form of an API for other projects. This API is part of the libmaus package. Conclusions In comparison with previous approaches to problems involving the collation of alignments by read name like the BAM to FastQ or duplication marking utilities our approach can often perform an equivalent task more efficiently in terms of the required main memory and run-time. Our BAM to FastQ conversion is faster than all widely known alternatives including Picard and bamUtil. Our duplicate marking is about as fast as the closest competitor bamUtil for small data sets and faster than all known alternatives on large and complex data sets.

  15. Does Weight Status Influence Weight-Related Beliefs and the Consumption of Sugar-Sweetened Beverages and Fast Food Purchases in Adolescents?

    ERIC Educational Resources Information Center

    Hearst, Mary O.; Pasch, Keryn E.; Fulkerson, Jayne A.; Lytle, Leslie A.

    2009-01-01

    Objective: To determine if weight status affects the relationship between weight-related beliefs and consumption of sugar-sweetened beverages (SSB) and fast and convenience store food purchases (FCFP). Design: Observational, cross-sectional. Setting: Twin Cities Metropolitan area, Minnesota, USA. Methods: Body composition and psychosocial survey…

  16. Children's Executive Function and High-Calorie, Low-Nutrient Food Intake: Mediating Effects of Child-Perceived Adult Fast Food Intake

    ERIC Educational Resources Information Center

    Tate, Eleanor B.; Unger, Jennifer B.; Chou, Chih-Ping; Spruijt-Metz, Donna; Pentz, Mary Ann; Riggs, Nathaniel R.

    2015-01-01

    Objective: This study tested the relationships among child executive function (EF), child-perceived parent fast food intake, and child self-reported subsequent consumption of high-calorie, low-nutrient (HCLN) food. Design: One year and 6-month longitudinal observation from a larger randomized controlled trial. Setting. Southern California…

  17. How Plastics Work

    NASA Astrophysics Data System (ADS)

    Bloomfield, Louis

    2013-03-01

    We encounter plastics every day, but despite their widespread use, amazing range of properties, and basic scientific underpinnings, most physicists--like most people--know relatively little about plastics. In contrast to hard crystalline and amorphous solids (e.g., metals, salts, ceramics, and glasses), we take plastics for granted, select them carelessly, and examine them more closely only on a need-to-know basis. By ignoring plastics until we need them, however, we risk not knowing what we don't know and using the wrong ones. To repurpose a familiar advertisement, ``there's a plastic for that.'' This talk will review some of the basic physics and science of plastics. It will examine the roles of temperature, order, intermolecular forces, entanglements, and linkages in plastics, and how those issues affect the properties of a given plastic. We'll stop along the way to recognize a few of the more familiar plastics, natural and synthetic, and explain some of their mechanical, chemical, and optical properties. The talk will conclude by explaining the remarkable properties of a plastic that has been largely misunderstood since its discovery 70 years ago: Silly Putty.

  18. History of surgical intervention of anterior shoulder instability.

    PubMed

    Levy, David M; Cole, Brian J; Bach, Bernard R

    2016-06-01

    Anterior glenohumeral instability most commonly affects younger patients and has shown high recurrence rates with nonoperative management. The treatment of anterior glenohumeral instability has undergone significant evolution over the 20th and 21 centuries. This article presents a retrospective comprehensive review of the history of different operative techniques for shoulder stabilization. Bankart first described an anatomic suture repair of the inferior glenohumeral ligament and anteroinferior labrum in 1923. Multiple surgeons have since described anatomic and nonanatomic repairs, and many of the early principles of shoulder stabilization have remained even as the techniques have changed. Some methods, such as the Magnusson-Stack procedure, Putti-Platt procedure, arthroscopic stapling, and transosseous suture fixation, have been almost completely abandoned. Other strategies, such as the Bankart repair, capsular shift, and remplissage, have persisted for decades and have been adapted for arthroscopic use. The future of anterior shoulder stabilization will continue to evolve with even newer practices, such as the arthroscopic Latarjet transfer. Further research and clinical experience will dictate which future innovations are ultimately embraced. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doubrawa Moreira, Paula; Annoni, Jennifer; Jonkman, Jason

    FAST.Farm is a medium-delity wind farm modeling tool that can be used to assess power and loads contributions of wind turbines in a wind farm. The objective of this paper is to undertake a calibration procedure to set the user parameters of FAST.Farm to accurately represent results from large-eddy simulations. The results provide an in- depth analysis of the comparison of FAST.Farm and large-eddy simulations before and after calibration. The comparison of FAST.Farm and large-eddy simulation results are presented with respect to streamwise and radial velocity components as well as wake-meandering statistics (mean and standard deviation) in the lateral andmore » vertical directions under different atmospheric and turbine operating conditions.« less

  20. Hybrid massively parallel fast sweeping method for static Hamilton-Jacobi equations

    NASA Astrophysics Data System (ADS)

    Detrixhe, Miles; Gibou, Frédéric

    2016-10-01

    The fast sweeping method is a popular algorithm for solving a variety of static Hamilton-Jacobi equations. Fast sweeping algorithms for parallel computing have been developed, but are severely limited. In this work, we present a multilevel, hybrid parallel algorithm that combines the desirable traits of two distinct parallel methods. The fine and coarse grained components of the algorithm take advantage of heterogeneous computer architecture common in high performance computing facilities. We present the algorithm and demonstrate its effectiveness on a set of example problems including optimal control, dynamic games, and seismic wave propagation. We give results for convergence, parallel scaling, and show state-of-the-art speedup values for the fast sweeping method.

  1. Distributed Function Mining for Gene Expression Programming Based on Fast Reduction.

    PubMed

    Deng, Song; Yue, Dong; Yang, Le-chan; Fu, Xiong; Feng, Ya-zhou

    2016-01-01

    For high-dimensional and massive data sets, traditional centralized gene expression programming (GEP) or improved algorithms lead to increased run-time and decreased prediction accuracy. To solve this problem, this paper proposes a new improved algorithm called distributed function mining for gene expression programming based on fast reduction (DFMGEP-FR). In DFMGEP-FR, fast attribution reduction in binary search algorithms (FAR-BSA) is proposed to quickly find the optimal attribution set, and the function consistency replacement algorithm is given to solve integration of the local function model. Thorough comparative experiments for DFMGEP-FR, centralized GEP and the parallel gene expression programming algorithm based on simulated annealing (parallel GEPSA) are included in this paper. For the waveform, mushroom, connect-4 and musk datasets, the comparative results show that the average time-consumption of DFMGEP-FR drops by 89.09%%, 88.85%, 85.79% and 93.06%, respectively, in contrast to centralized GEP and by 12.5%, 8.42%, 9.62% and 13.75%, respectively, compared with parallel GEPSA. Six well-studied UCI test data sets demonstrate the efficiency and capability of our proposed DFMGEP-FR algorithm for distributed function mining.

  2. Fast track in hip arthroplasty

    PubMed Central

    Hansen, Torben Bæk

    2017-01-01

    ‘Fast-track’ surgery was introduced more than 20 years ago and may be defined as a co-ordinated peri-operative approach aimed at reducing surgical stress and facilitating post-operative recovery.The fast-track programmes have now been introduced into total hip arthroplasty (THA) surgery with reduction in post-operative length of stay, shorter convalescence and rapid functional recovery without increased morbidity and mortality. This has been achieved by focusing on a multidisciplinary collaboration and establishing ‘fast-track’ units, with a well-defined organisational set-up tailored to deliver an accelerated peri-operative course of fast-track surgical THA procedures.Fast-track THA surgery now works extremely well in the standard THA patient. However, all patients are different and fine-tuning of the multiple areas in fast-track pathways to get patients with special needs or high co-morbidity burden through a safe and effective fast-track THA pathway is important.In this narrative review, the principles of fast-track THA surgery are presented together with the present status of implementation and perspectives for further improvements. Cite this article: EFORT Open Rev 2017;2. DOI: 10.1302/2058-5241.2.160060. Originally published online at www.efortopenreviews.org PMID:28630756

  3. Report On Stakeholders Analysis Fast-Trac Phase Iii Deliverables, #5 One Set Of Stakeholder Readings, #6. Final Version Of The Stakeholders? Questionnaire, #7. Stakeholders? Analysis Report

    DOT National Transportation Integrated Search

    1996-12-10

    THIS STUDY WAS UNDERTAKEN TO IDENTIFY AND EVALUATE CRITERIA BY WHICH THE PUBLIC, AND CERTAIN STAKEHOLDER GROUPS WITHIN THE PUBLIC, WILL JUDGE THE MERITS OF THE FAST-TRAC SYSTEM. OVER A PERIOD OF TWO YEARS, THREE SURVEYS WERE CONDUCTED TO OBTAIN SPECI...

  4. Determinants of Children's Use of and Time Spent in Fast-Food and Full-Service Restaurants

    ERIC Educational Resources Information Center

    McIntosh, Alex; Kubena, Karen S.; Tolle, Glen; Dean, Wesley; Kim, Mi-Jeong; Jan, Jie-Sheng; Anding, Jenna

    2011-01-01

    Objective: Identify parental and children's determinants of children's use of and time spent in fast-food (FF) and full-service (FS) restaurants. Design: Analysis of cross-sectional data. Setting: Parents were interviewed by phone; children were interviewed in their homes. Participants: Parents and children ages 9-11 or 13-15 from 312 families…

  5. Validity of the Miller forensic assessment of symptoms test in psychiatric inpatients.

    PubMed

    Veazey, Connie H; Wagner, Alisha L; Hays, J Ray; Miller, Holly A

    2005-06-01

    This study investigated the validity of the Miller Forensic Assessment of Symptoms Test (M-FAST), a brief measure of malingering, in an inpatient psychiatric sample of 70. Among those patients who also completed the Personality Assessment Inventory (N=44), Total M-FAST score was related in the expected directions to the Personality Assessment Inventory validity scales and indexes, providing evidence for concurrent validity of the M-FAST. With the PAI malingering index used as a criterion, we examined the diagnostic efficiency of the M-FAST and found a cut score of 8 represented the best balance of sensitivity, specificity, positive predictive power, and negative predictive power. Based on this cut-score of 8, 16% of the population was classified as malingering. The M-FAST appears to be an excellent rapid screen for symptom exaggeration in this population and setting.

  6. Pilot study to investigate the feasibility of the Home Falls and Accidents Screening Tool (HOME FAST) to identify older Malaysian people at risk of falls

    PubMed Central

    Romli, Muhammad Hibatullah; Mackenzie, Lynette; Lovarini, Meryl; Tan, Maw Pin

    2016-01-01

    Objective The relationship between home hazards and falls in older Malaysian people is not yet fully understood. No tools to evaluate the Malaysian home environment currently exist. Therefore, this study aimed to pilot the Home Falls and Accidents Screening Tool (HOME FAST) to identify hazards in Malaysian homes, to evaluate the feasibility of using the HOME FAST in the Malaysian Elders Longitudinal Research (MELoR) study and to gather preliminary data about the experience of falls among a small sample of Malaysian older people. Design A cross-sectional pilot study was conducted. Setting An urban setting in Kuala Lumpur. Participants 26 older people aged 60 and over were recruited from the control group of a related research project in Malaysia, in addition to older people known to the researchers. Primary outcome measure The HOME FAST was applied with the baseline survey for the MELoR study via a face-to-face interview and observation of the home by research staff. Results The majority of the participants were female, of Malay or Chinese ethnicity and living with others in a double-storeyed house. Falls were reported in the previous year by 19% and 80% of falls occurred at home. Gender and fear of falling had the strongest associations with home hazards. Most hazards were detected in the bathroom area. A small number of errors were detected in the HOME FAST ratings by researchers. Conclusions The HOME FAST is feasible as a research and clinical tool for the Malaysian context and is appropriate for use in the MELoR study. Home hazards were prevalent in the homes of older people and further research with the larger MELoR sample is needed to confirm the validity of using the HOME FAST in Malaysia. Training in the use of the HOME FAST is needed to ensure accurate use by researchers. PMID:27531736

  7. Nodal weighting factor method for ex-core fast neutron fluence evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chiang, R. T.

    The nodal weighting factor method is developed for evaluating ex-core fast neutron flux in a nuclear reactor by utilizing adjoint neutron flux, a fictitious unit detector cross section for neutron energy above 1 or 0.1 MeV, the unit fission source, and relative assembly nodal powers. The method determines each nodal weighting factor for ex-core neutron fast flux evaluation by solving the steady-state adjoint neutron transport equation with a fictitious unit detector cross section for neutron energy above 1 or 0.1 MeV as the adjoint source, by integrating the unit fission source with a typical fission spectrum to the solved adjointmore » flux over all energies, all angles and given nodal volume, and by dividing it with the sum of all nodal weighting factors, which is a normalization factor. Then, the fast neutron flux can be obtained by summing the various relative nodal powers times the corresponding nodal weighting factors of the adjacent significantly contributed peripheral assembly nodes and times a proper fast neutron attenuation coefficient over an operating period. A generic set of nodal weighting factors can be used to evaluate neutron fluence at the same location for similar core design and fuel cycles, but the set of nodal weighting factors needs to be re-calibrated for a transition-fuel-cycle. This newly developed nodal weighting factor method should be a useful and simplified tool for evaluating fast neutron fluence at selected locations of interest in ex-core components of contemporary nuclear power reactors. (authors)« less

  8. Fast Setting Cement - Literature Survey

    DTIC Science & Technology

    1973-01-01

    materials tested that did not meet the requirements were Portland c~ment, Lumnite cement, Por-rock, Mirament, Speed Crete, Floc-roc, Sika accelerators...Sika’Chemical Corp., Data sheets on Sigunit and other Sika quick-setting. imaterials. (F) Simeonov, Bozhinov, et al, "Acceleration of Hardening of Concrete

  9. A review of level-set methods and some recent applications

    NASA Astrophysics Data System (ADS)

    Gibou, Frederic; Fedkiw, Ronald; Osher, Stanley

    2018-01-01

    We review some of the recent advances in level-set methods and their applications. In particular, we discuss how to impose boundary conditions at irregular domains and free boundaries, as well as the extension of level-set methods to adaptive Cartesian grids and parallel architectures. Illustrative applications are taken from the physical and life sciences. Fast sweeping methods are briefly discussed.

  10. Hybrid massively parallel fast sweeping method for static Hamilton–Jacobi equations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Detrixhe, Miles, E-mail: mdetrixhe@engineering.ucsb.edu; University of California Santa Barbara, Santa Barbara, CA, 93106; Gibou, Frédéric, E-mail: fgibou@engineering.ucsb.edu

    The fast sweeping method is a popular algorithm for solving a variety of static Hamilton–Jacobi equations. Fast sweeping algorithms for parallel computing have been developed, but are severely limited. In this work, we present a multilevel, hybrid parallel algorithm that combines the desirable traits of two distinct parallel methods. The fine and coarse grained components of the algorithm take advantage of heterogeneous computer architecture common in high performance computing facilities. We present the algorithm and demonstrate its effectiveness on a set of example problems including optimal control, dynamic games, and seismic wave propagation. We give results for convergence, parallel scaling,more » and show state-of-the-art speedup values for the fast sweeping method.« less

  11. Fasting target for hyperglycaemia in pregnancy.

    PubMed

    Moses, Robert G; Wong, Veronica C K; Lambert, Kelly; Morris, Gary J

    2016-10-01

    Knowledge of the fasting plasma glucose of healthy women may assist in the setting of treatment targets for women with hyperglycaemia in pregnancy (HIP). This study examines the pregnancy glucose tolerance test results of 3344 women without HIP collected over a three-year period. The median fasting plasma glucose was 4.4 mmol/L with an interquartile range of 4.2-4.6 mmol/L and a 5th to 95th centile of 3.8-4.9 mmol/L. As the diagnostic fasting glucose level for HIP is ≥5.1 mmol/L, these data support a treatment target of ≤5.0 mmol/L. © 2016 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  12. Validation of the SimSET simulation package for modeling the Siemens Biograph mCT PET scanner

    NASA Astrophysics Data System (ADS)

    Poon, Jonathan K.; Dahlbom, Magnus L.; Casey, Michael E.; Qi, Jinyi; Cherry, Simon R.; Badawi, Ramsey D.

    2015-02-01

    Monte Carlo simulation provides a valuable tool in performance assessment and optimization of system design parameters for PET scanners. SimSET is a popular Monte Carlo simulation toolkit that features fast simulation time, as well as variance reduction tools to further enhance computational efficiency. However, SimSET has lacked the ability to simulate block detectors until its most recent release. Our goal is to validate new features of SimSET by developing a simulation model of the Siemens Biograph mCT PET scanner and comparing the results to a simulation model developed in the GATE simulation suite and to experimental results. We used the NEMA NU-2 2007 scatter fraction, count rates, and spatial resolution protocols to validate the SimSET simulation model and its new features. The SimSET model overestimated the experimental results of the count rate tests by 11-23% and the spatial resolution test by 13-28%, which is comparable to previous validation studies of other PET scanners in the literature. The difference between the SimSET and GATE simulation was approximately 4-8% for the count rate test and approximately 3-11% for the spatial resolution test. In terms of computational time, SimSET performed simulations approximately 11 times faster than GATE simulations. The new block detector model in SimSET offers a fast and reasonably accurate simulation toolkit for PET imaging applications.

  13. Fast-ion Dα spectrum diagnostic in the EAST

    NASA Astrophysics Data System (ADS)

    Hou, Y. M.; Wu, C. R.; Huang, J.; Heidbrink, W. W.; von Hellermann, M. G.; Xu, Z.; Jin, Z.; Chang, J. F.; Zhu, Y. B.; Gao, W.; Chen, Y. J.; Lyu, B.; Hu, R. J.; Zhang, P. F.; Zhang, L.; Gao, W.; Wu, Z. W.; Yu, Y.; Ye, M. Y.

    2016-11-01

    In toroidal magnetic fusion devices, fast-ion D-alpha diagnostic (FIDA) is a powerful method to study the fast-ion feature. The fast-ion characteristics can be inferred from the Doppler shifted spectrum of Dα light according to charge exchange recombination process between fast ions and probe beam. Since conceptual design presented in the last HTPD conference, significant progress has been made to apply FIDA systems on the Experimental Advanced Superconducting Tokamak (EAST). Both co-current and counter-current neutral beam injectors are available, and each can deliver 2-4 MW beam power with 50-80 keV beam energy. Presently, two sets of high throughput spectrometer systems have been installed on EAST, allowing to capture passing and trapped fast-ion characteristics simultaneously, using Kaiser HoloSpec transmission grating spectrometer and Bunkoukeiki FLP-200 volume phase holographic spectrometer coupled with Princeton Instruments ProEM 1024B eXcelon and Andor DU-888 iXon3 1024 CCD camera, respectively. This paper will present the details of the hardware descriptions and experimental spectrum.

  14. THE FIRST LUNAR MAP OF THE AVERAGE SOIL ATOMIC MASS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O. GASNAULT; W. FELDMAN; ET AL

    2001-01-01

    Measurements of indexes of lunar surface composition were successfully made during Lunar Prospector (LP) mission, using the Neutron Spectrometers (NS) [1]. This capability is demonstrated for fast neutrons in Plates 1 of Maurice et al. [2] (similar to Figure 2 here). Inspection shows a clear distinction between mare basalt (bright) and highland terranes [2]. Fast neutron simulations demonstrate the sensitivity of the fast neutron leakage flux to the presence of iron and titanium in the soil [3]. The dependence of the flux to a third element (calcium or aluminum) was also suspected [4]. We expand our previous work in thismore » study by estimating fast neutron leakage fluxes for a more comprehensive set of assumed lunar compositions. We find a strong relationship between the fast neutron fluxes and the average soil atomic mass: . This relation can be inverted to provide a map of from the measured map of fast neutrons from the Moon.« less

  15. Determining the effects of early gestation in utero heat stress on postnatal fasting heat production and circulating biomarkers associated with metabolism in growing pigs

    USDA-ARS?s Scientific Manuscript database

    The study objective was to determine the effects of in utero heat stress (IUHS) on postnatal fasting heat production (FHP) in growing pigs. Based on our previous observation of increased postnatal core body temperature ‘set-point’ in IUHS pigs, we hypothesized that FHP would be greater during postna...

  16. Study on beam geometry and image reconstruction algorithm in fast neutron computerized tomography at NECTAR facility

    NASA Astrophysics Data System (ADS)

    Guo, J.; Bücherl, T.; Zou, Y.; Guo, Z.

    2011-09-01

    Investigations on the fast neutron beam geometry for the NECTAR facility are presented. The results of MCNP simulations and experimental measurements of the beam distributions at NECTAR are compared. Boltzmann functions are used to describe the beam profile in the detection plane assuming the area source to be set up of large number of single neutron point sources. An iterative algebraic reconstruction algorithm is developed, realized and verified by both simulated and measured projection data. The feasibility for improved reconstruction in fast neutron computerized tomography at the NECTAR facility is demonstrated.

  17. Preoperative fasting among burns patients in an acute care setting: a best practice implementation project.

    PubMed

    Giuliani, Sara; McArthur, Alexa; Greenwood, John

    2015-11-01

    Major burn injury patients commonly fast preoperatively before multiple surgical procedures. The Societies of Anesthesiology in Europe and the United States recommend fasting from clear fluids for two hours and solids for six to eight hours preoperatively. However, at the Royal Adelaide Hospital, patients often fast from midnight proceeding the day of surgery. This project aims to promote evidence-based practice to minimize extended preoperative fasting in major burn patients. A baseline audit was conducted measuring the percentage compliance with audit criteria, specifically on preoperative fasting documentation and appropriate instructions in line with evidence-based guidelines. Strategies were then implemented to address areas of non-compliance, which included staff education, development of documentation tools and completion of a perioperative feeding protocol for major burn patients. Following this, a post implementation audit assessed the extent of change compared with the baseline audit results. Education on evidence-based fasting guidelines was delivered to 54% of staff. This resulted in a 19% improvement in compliance with fasting documentation and a 52% increase in adherence to appropriate evidence-based instructions. There was a notable shift from the most common fasting instruction being "fast from midnight" to "fast from 03:00 hours", with an overall four-hour reduction in fasting per theater admission. These results demonstrate that education improves compliance with documentation and preoperative fasting that is more reflective of evidence-based practice. Collaboration with key stakeholders and a hospital wide fasting protocol is warranted to sustain change and further advance compliance with evidence-based practice at an organizational level.

  18. Effect of Vildagliptin Versus Sulfonylurea in Muslim Patients with Type 2 Diabetes Fasting During Ramadan in Egypt: Results from VIRTUE Study.

    PubMed

    Khattab, Mohamed; Mahmoud, Khalifa; Shaltout, Inass

    2016-09-01

    Fasting in patients with type 2 diabetes mellitus (T2DM) is associated with high risk of hypoglycemia. The aim of this study was to compare the effectiveness and safety of vildagliptin in T2DM patients fasting during Ramadan in a real-life setting in Egypt. In this 16-week prospective and noninterventional study, data were collected up to 6 weeks before and after Ramadan fasting. Patients who had received vildagliptin or sulfonylurea (SU) either as dual therapy with metformin or as monotherapy were enrolled into the study. Two hundred fifty four patients were enrolled in the study, out of which 246 [121 (97.6%) treated with vildagliptin and 125 (99.2%) with SU] were included in the safety analysis set. A significantly lower proportion of patients experienced ≥1 hypoglycemic event (HE) with vildagliptin as compared to those receiving SUs (1.7% vs. 19.2%, respectively; p < 0.001). No patient in either group reported a grade 2 HE. At week 16, mean change in HbA1c from baseline for vildagliptin and SU were -0.1% and +0.3%, respectively, with a between-treatment difference of -0.4% (p < 0.001). Mean change in body weight from baseline for vildagliptin and SU were -0.8 and -0.1 kg, with a between-treatment difference of -0.7 kg (p = 0.011). A higher proportion of SU-treated patients experienced adverse events compared to those treated with vildagliptin (23.2% vs. 5.8%, respectively), the primary reason being the high incidence of hypoglycemia in the SU group (n = 24, 19.2%). Treatment with vildagliptin was associated with lower incidence of hypoglycemia compared with SU and showed good glycemic and weight control in patients with T2DM fasting during Ramadan in a real-life setting in Egypt. Novartis Pharma AG.

  19. Distributed Adaptive Binary Quantization for Fast Nearest Neighbor Search.

    PubMed

    Xianglong Liu; Zhujin Li; Cheng Deng; Dacheng Tao

    2017-11-01

    Hashing has been proved an attractive technique for fast nearest neighbor search over big data. Compared with the projection based hashing methods, prototype-based ones own stronger power to generate discriminative binary codes for the data with complex intrinsic structure. However, existing prototype-based methods, such as spherical hashing and K-means hashing, still suffer from the ineffective coding that utilizes the complete binary codes in a hypercube. To address this problem, we propose an adaptive binary quantization (ABQ) method that learns a discriminative hash function with prototypes associated with small unique binary codes. Our alternating optimization adaptively discovers the prototype set and the code set of a varying size in an efficient way, which together robustly approximate the data relations. Our method can be naturally generalized to the product space for long hash codes, and enjoys the fast training linear to the number of the training data. We further devise a distributed framework for the large-scale learning, which can significantly speed up the training of ABQ in the distributed environment that has been widely deployed in many areas nowadays. The extensive experiments on four large-scale (up to 80 million) data sets demonstrate that our method significantly outperforms state-of-the-art hashing methods, with up to 58.84% performance gains relatively.

  20. [Detection of the main quality indicators in red wine with infrared spectroscopy based on FastICA and neural network].

    PubMed

    Fang, Li-Min; Lin, Min

    2009-08-01

    For the rapid detection of the ethanol, pH and rest sugar in red wine, infrared (IR) spectra of 44 wine samples were analyzed. The algorithm of fast independent component analysis (FastICA) was used to decompose the data of IR spectra, and their independent components and the mixing matrix were obtained. Then, the ICA-NNR calibration model with three-level artificial neural network (ANN) structure was built by using back-propagation (BP) algorithm. The models were used to estimate the contents of ethanol, pH and rest sugar in red wine samples for both in calibration set and predicted set. Correlation coefficient (r) of prediction and root mean square error of prediction (RMSEP) were used as the evaluation indexes. The results indicate that the r and RMSEP for the prediction of ethanol content, pH and rest sugar content are 0.953, 0.983 and 0.994, and 0.161, 0.017 and 0.181, respectively. The maximum relative deviations between the ICA-NNR method predicted value and referenced value of the 22 samples in predicted set are less than 4%. The results of this paper provide a foundation for the application and further development of IR on-line red wine analyzer.

  1. Type 2 diabetes management in nurse-led primary healthcare settings in urban and rural Cameroon.

    PubMed

    Kengne, Andre Pascal; Fezeu, Leopold; Sobngwi, Eugene; Awah, Paschal Kum; Aspray, Terence J; Unwin, Nigel C; Mbanya, Jean-Claude

    2009-08-01

    To implement a protocol-driven primary nurse-led care for type 2 diabetes in rural and urban Cameroon. We set-up three primary healthcare clinics in Yaounde (Capital city) and two in the Bafut rural health district. Participants were 225 (17% rural) patients with known or newly diagnosed type 2 diabetes, not requiring insulin, referred either from a baseline survey (38 patients, 17%), or secondarily attracted to the clinics. Protocol-driven glucose and blood pressure control were delivered by trained nurses. The main outcomes were trajectories of fasting capillary glucose and blood pressure indices, and differences in the mean levels between baseline and final visits. The total duration of follow-up was 1110 patient-months. During follow-up, there was a significant downward trend in fasting capillary glucose overall (p<0.001) and in most subgroups of participants. Between baseline and final visits, mean fasting capillary glucose dropped by 1.6 mmol/L (95% CI: 0.8-2.3; p< or =0.001). Among those with hypertension, blood pressure also decreased significantly for systolic and marginally for diastolic blood pressure. No major significant change was noticed for body weight. Nurses may be potential alternatives to improve access to diabetes care in settings where physicians are not available.

  2. VUV absorption spectroscopy measurements of the role of fast neutral atoms in a high-power gap breakdown

    NASA Astrophysics Data System (ADS)

    Filuk, A. B.; Bailey, J. E.; Cuneo, M. E.; Lake, P. W.; Nash, T. J.; Noack, D. D.; Maron, Y.

    2000-12-01

    The maximum power achieved in a wide variety of high-power devices, including electron and ion diodes, z pinches, and microwave generators, is presently limited by anode-cathode gap breakdown. A frequently discussed hypothesis for this effect is ionization of fast neutral atoms injected throughout the anode-cathode gap during the power pulse. We describe a newly developed diagnostic tool that provides a direct test of this hypothesis. Time-resolved vacuum-ultraviolet absorption spectroscopy is used to directly probe fast neutral atoms with 1-mm spatial resolution in the 10-mm anode-cathode gap of the SABRE 5 MV, 1 TW applied-B ion diode. Absorption spectra collected during Ar RF glow discharges and with CO2 gas fills confirm the reliability of the diagnostic technique. Throughout the 50-100 ns ion diode pulses no measurable neutral absorption was seen, setting upper limits of (0.12-1.5)×1014 cm-3 for ground-state fast neutral atom densities of H, C, N, O, and F. The absence of molecular absorption bands also sets upper limits of (0.16-1.2)×1015 cm-3 for common simple molecules. These limits are low enough to rule out ionization of fast neutral atoms as a breakdown mechanism. Breakdown due to ionization of molecules is also found to be unlikely. This technique can now be applied to quantify the role of neutral atoms in other high-power devices.

  3. Ability among adolescents for the metabolic syndrome to predict elevations in factors associated with type 2 diabetes and cardiovascular disease: data from the national health and nutrition examination survey 1999-2006.

    PubMed

    DeBoer, Mark D; Gurka, Matthew J

    2010-08-01

    The aim of this study was to compare currently proposed sets of pediatric metabolic syndrome criteria for the ability to predict elevations in "surrogate" factors that are associated with metabolic syndrome and with future cardiovascular disease and type 2 diabetes mellitus. These surrogate factors were fasting insulin, hemoglobin A1c (HbA1c), high-sensitivity C-reactive protein (hsCRP), and uric acid. Waist circumference (WC), blood pressure, triglycerides, high-density lipoprotein cholesterol (HDL-C), fasting glucose, fasting insulin, HbA1c, hsCRP, and uric acid measurements were obtained from 2,624 adolescent (12-18 years old) participants of the 1999-2006 National Health and Nutrition Examination Surveys. We identified children with metabolic syndrome as defined by six commonly used sets of pediatric metabolic syndrome criteria. We then defined elevations in the surrogate factors as values in the top 5% for the cohort and calculated sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for each set of metabolic syndrome criteria and for each surrogate factor. Current pediatric metabolic syndrome criteria exhibited variable sensitivity and specificity for surrogate predictions. Metabolic syndrome criteria had the highest sensitivity for predicting fasting insulin (40-70%), followed by uric acid (31-54%), hsCRP (13-31%), and HbA1c (7-21%). The criteria of de Ferranti (which includes children with WC >75(th) percentile, compared to all other sets including children with WC >90(th) percentile) exhibited the highest sensitivity for predicting each of the surrogates, with only modest decrease in specificity compared to the other sets of criteria. However, the de Ferranti criteria also exhibited the lowest PPV values. Conversely, the pediatric International Diabetes Federation criteria exhibited the lowest sensitivity and the highest specificity. Pediatric metabolic syndrome criteria exhibit moderate sensitivity for detecting elevations in surrogate factors associated with metabolic syndrome and with risk for future disease. Inclusion of children with more modestly elevated WC improved sensitivity.

  4. Three Days of Intermittent Fasting: Repeated-Sprint Performance Decreased by Vertical-Stiffness Impairment.

    PubMed

    Cherif, Anissa; Meeusen, Romain; Farooq, Abdulaziz; Ryu, Joong; Fenneni, Mohamed Amine; Nikolovski, Zoran; Elshafie, Sittana; Chamari, Karim; Roelands, Bart

    2017-03-01

    To examine the effects of 3 d of intermittent fasting (3d-IF: abstaining from eating/drinking from dawn to sunset) on physical performance and metabolic responses to repeated sprints (RSs). Twenty-one active males performed an RS test (2 sets: 5 × 5-s maximal sprints with 25 s of recovery between and 3 min of recovery between sets on an instrumented treadmill) in 2 conditions: counterbalanced fed/control session (CS) and fasting session (FS). Biomechanical and biochemical markers were assessed preexercise and postexercise. Significant main effects of IF were observed for sprints: maximal speed (P = .016), mean speed (P = .015), maximal power (P = .035), mean power (P = .049), vertical stiffness (P = .032), and vertical center-of-mass displacement (P = .047). Sprint speed and vertical stiffness decreased during the 1st (P = .003 and P = .005) and 2nd sprints (P = .046 and P = .048) of set 2, respectively. Postexercise insulin decreased in CS (P = .023) but not in FS (P = .230). Free-fatty-acid levels were higher in FS than in CS at preexercise (P < .001) and at postexercise (P = .009). High-density lipoprotein cholesterol (HDL-C) was higher at postexercise in FS (1.32 ± 0.22 mmol/L) than in CS (1.26 ± 0.21 mmol/L, P = .039). The triglyceride (TG) concentration was decreased in FS (P < .05) compared with CS. 3d-IF impaired speed and power through a decrease in vertical stiffness during the initial runs of the 2nd set of RS. The findings of the current study confirmed the benefits of 3d-IF: improved HDL-C and TG profiles while maintaining total cholesterol and low-density lipoprotein cholesterol levels. Moreover, improving muscle power might be a key factor to retain a higher vertical stiffness and to partly counteract the negative effects of intermittent fasting.

  5. Compact Single Site Resolution Cold Atom Experiment for Adiabatic Quantum Computing

    DTIC Science & Technology

    2016-02-03

    goal of our scientific investigation is to demonstrate high fidelity and fast atom-atom entanglement between physically 1. REPORT DATE (DD-MM-YYYY) 4...of our scientific investigation is to demonstrate high fidelity and fast atom-atom entanglement between physically separated and optically addressed...Specifically, we will design and construct a set of compact single atom traps with integrated optics, suitable for heralded entanglement and loophole

  6. (NTF) National Transonic Facility Test 213-SFW Flow Control II,

    NASA Image and Video Library

    2012-11-19

    (NTF) National Transonic Facility Test 213-SFW Flow Control II, Fast-MAC Model: The fundamental Aerodynamics Subsonic Transonic-Modular Active Control (Fast-MAC) Model was tested for the 2nd time in the NTF. The objectives were to document the effects of Reynolds numbers on circulation control aerodynamics and to develop and open data set for CFD code validation. Image taken in building 1236, National Transonic Facility

  7. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout

    NASA Astrophysics Data System (ADS)

    England, Troy; Lilly, Michael; Curry, Matthew; Carr, Stephen; Carroll, Malcolm

    Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout of electrons bound to Si:P donors. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will introduce two new amplifier topologies that provide excellent gain versus power tradeoffs using silicon-germanium (SiGe) heterojunction bipolar transistors (HBTs). The AC HBT allows in-situ adjustment of power dissipation during an experiment and can provide gain in the millikelvin temperature regime while dissipating less than 500 nW. The AC Current Amplifier maximizes gain at nearly 800 A/A. We will also show results of using these amplifiers with SETs at 4 K. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout.

  8. Setting the magic angle for fast magic-angle spinning probes.

    PubMed

    Penzel, Susanne; Smith, Albert A; Ernst, Matthias; Meier, Beat H

    2018-06-15

    Fast magic-angle spinning, coupled with 1 H detection is a powerful method to improve spectral resolution and signal to noise in solid-state NMR spectra. Commercial probes now provide spinning frequencies in excess of 100 kHz. Then, one has sufficient resolution in the 1 H dimension to directly detect protons, which have a gyromagnetic ratio approximately four times larger than 13 C spins. However, the gains in sensitivity can quickly be lost if the rotation angle is not set precisely. The most common method of magic-angle calibration is to optimize the number of rotary echoes, or sideband intensity, observed on a sample of KBr. However, this typically uses relatively low spinning frequencies, where the spinning of fast-MAS probes is often unstable, and detection on the 13 C channel, for which fast-MAS probes are typically not optimized. Therefore, we compare the KBr-based optimization of the magic angle with two alternative approaches: optimization of the splitting observed in 13 C-labeled glycine-ethylester on the carbonyl due to the Cα-C' J-coupling, or optimization of the H-N J-coupling spin echo in the protein sample itself. The latter method has the particular advantage that no separate sample is necessary for the magic-angle optimization. Copyright © 2018. Published by Elsevier Inc.

  9. Magnetization transfer studies of the fast and slow tissue water diffusion components in the human brain.

    PubMed

    Mulkern, Robert V; Vajapeyam, Sridhar; Haker, Steven J; Maier, Stephan E

    2005-05-01

    Magnetization transfer (MT) properties of the fast and slow diffusion components recently observed in the human brain were assessed experimentally. One set of experiments, performed at 1.5 T in healthy volunteers, was designed to determine whether the amplitudes of fast and slow diffusion components, differentiated on the basis of biexponential fits to signal decays over a wide range of b-factors, demonstrated a different or similar magnetization transfer ratio (MTR). Another set of experiments, performed at 3 T in healthy volunteers, was designed to determine whether MTRs differed when measured from high signal-to-noise images acquired with b-factor weightings of 350 vs 3500 s/mm2. The 3 T studies included measurements of MTR as a function of off-resonance frequency for the MT pulse at both low and high b-factors. The primary conclusion drawn from all the studies is that there appears to be no significant difference between the magnetization transfer properties of the fast and slow tissue water diffusion components. The conclusions do not lend support to a direct interpretation of the 'components' of the biexponential diffusion decay in terms of the 'compartments' associated with intra- and extracellular water. Copyright 2004 John Wiley & Sons, Ltd.

  10. Development and evaluation of a novel, real time mobile telesonography system in management of patients with abdominal trauma: study protocol.

    PubMed

    Ogedegbe, Chinwe; Morchel, Herman; Hazelwood, Vikki; Chaplin, William F; Feldman, Joseph

    2012-12-18

    Despite the use of e-FAST in management of patients with abdominal trauma, its utility in prehospital setting is not widely adopted. The goal of this study is to develop a novel portable telesonography (TS) system and evaluate the comparability of the quality of images obtained via this system among healthy volunteers who undergo e-FAST abdominal examination in a moving ambulance and at the ED. We hypothesize that: (1) real-time ultrasound images of acute trauma patients in the pre-hospital setting can be obtained and transmitted to the ED via the novel TS system; and (2) Ultrasound images transmitted to the hospital from the real-time TS system will be comparable in quality to those obtained in the ED. Study participants are three healthy volunteers (one each with normal, overweight and obese BMI category). The ultrasound images will be obtained by two ultrasound-trained physicians The TS is a portable sonogram (by Sonosite) interfaced with a portable broadcast unit (by Live-U). Two UTPs will conduct e-FAST examinations on healthy volunteers in moving ambulances and transmit the images via cellular network to the hospital server, where they are stored. Upon arrival in the ED, the same UTPs will obtain another set of images from the volunteers, which are then compared to those obtained in the moving ambulances by another set of blinded UTPs (evaluators) using a validated image quality scale, the Questionnaire for User Interaction Satisfaction (QUIS). Findings from this study will provide needed data on the validity of the novel TS in transmitting live images from moving ambulances to images obtained in the ED thus providing opportunity to facilitate medical care of a patient located in a remote or austere setting.

  11. Studies on transient characteristics of unipolar resistive switching processes in TiO2 thin film grown by atomic layer deposition

    NASA Astrophysics Data System (ADS)

    Sahu, Vikas Kumar; Das, Amit K.; Ajimsha, R. S.; Misra, P.

    2018-05-01

    The transient characteristics of resistive switching processes have been investigated in TiO2 thin films grown by atomic layer deposition (ALD) to study the temporal evolution of the switching processes and measure the switching times. The reset and set switching times of unipolar Au/TiO2/Pt devices were found to be ~250 µs and 180 ns, respectively in the voltage windows of 0.5–0.9 V for reset and 1.9–4.8 V for set switching processes, obtained from quasi-static measurements. The reset switching time decreased exponentially with increasing amplitude of applied reset voltage pulse, while the set switching time remained insensitive to the amplitude of the set voltage pulse. A fast reset process with a switching time of ~400 ns was achieved by applying a reset voltage of ~1.8 V, higher than that of the quasi-static reset voltage window but below the set voltage window. The sluggish reset process in TiO2 thin film and the dependence of the reset switching time on the amplitude of the applied voltage pulse was understood on the basis of a self-accelerated thermal dissolution model of conducting filaments (CFs), where a higher temperature of the CFs owing to enhanced Joule heating at a higher applied voltage imposes faster diffusion of oxygen vacancies, resulting in a shorter reset switching time. Our results clearly indicate that fast resistive switching with switching times in hundreds of nanoseconds can be achieved in ALD-grown TiO2 thin films. This may find applications in fast non-volatile unipolar resistive switching memories.

  12. High Intensity High Volume Interval Training Improves Endurance Performance and Induces a Nearly Complete Slow-to-Fast Fiber Transformation on the mRNA Level.

    PubMed

    Eigendorf, Julian; May, Marcus; Friedrich, Jan; Engeli, Stefan; Maassen, Norbert; Gros, Gerolf; Meissner, Joachim D

    2018-01-01

    We present here a longitudinal study determining the effects of two 3 week-periods of high intensity high volume interval training (HIHVT) (90 intervals of 6 s cycling at 250% maximum power, P max /24 s) on a cycle ergometer. HIHVT was evaluated by comparing performance tests before and after the entire training (baseline, BSL, and endpoint, END) and between the two training sets (intermediate, INT). The mRNA expression levels of myosin heavy chain (MHC) isoforms and markers of energy metabolism were analyzed in M. vastus lateralis biopsies by quantitative real-time PCR. In incremental tests peak power (P peak ) was increased, whereas V ˙ O 2peak was unaltered. Prolonged time-to-exhaustion was found in endurance tests with 65 and 80% P max at INT and END. No changes in blood levels of lipid metabolites were detected. Training-induced decreases of hematocrit indicate hypervolemia. A shift from slow MHCI/β to fast MHCIIa mRNA expression occurred after the first and second training set. The mRNA expression of peroxisome proliferator-activated receptor gamma coactivator 1α (PGC-1α), a master regulator of oxidative energy metabolism, decreased after the second training set. In agreement, a significant decrease was also found for citrate synthase mRNA after the second training set, indicating reduced oxidative capacity. However, mRNA expression levels of glycolytic marker enzyme glyceraldehyde-3-phosphate dehydrogenase did not change after the first and second training set. HIHVT induced a nearly complete slow-to-fast fiber type transformation on the mRNA level, which, however, cannot account for the improvements of performance parameters. The latter might be explained by the well-known effects of hypervolemia on exercise performance.

  13. Detecting spam comments on Indonesia’s Instagram posts

    NASA Astrophysics Data System (ADS)

    Septiandri, Ali Akbar; Wibisono, Okiriza

    2017-01-01

    In this paper we experimented with several feature sets for detecting spam comments in social media contents authored by Indonesian public figures. We define spam comments as comments which have promotional purposes (e.g. referring other users to products and services) and thus not related to the content to which the comments are posted. Three sets of features are evaluated for detecting spams: (1) hand-engineered features such as comment length, number of capital letters, and number of emojis, (2) keyword features such as whether the comment contains advertising words or product-related words, and (3) text features, namely, bag-of-words, TF-IDF, and fastText embeddings, each combined with latent semantic analysis. With 24,000 manually-annotated comments scraped from Instagram posts authored by more than 100 Indonesian public figures, we compared the performance of these feature sets and their combinations using 3 popular classification algorithms: Na¨ıve Bayes, SVM, and XGBoost. We find that using all three feature sets (with fastText embedding for the text features) gave the best F 1-score of 0.9601 on a holdout dataset. More interestingly, fastText embedding combined with hand-engineered features (i.e. without keyword features) yield similar F 1-score of 0.9523, and McNemar’s test failed to reject the hypothesis that the two results are not significantly different. This result is important as keyword features are largely dependent on the dataset and may not be as generalisable as the other feature sets when applied to new data. For future work, we hope to collect bigger and more diverse dataset of Indonesian spam comments, improve our model’s performance and generalisability, and publish a programming package for others to reliably detect spam comments.

  14. The clinical diagnostic accuracy of rapid detection of healthcare-associated bloodstream infection in intensive care using multipathogen real-time PCR technology

    PubMed Central

    Dunn, Graham; Chadwick, Paul; Young, Duncan; Bentley, Andrew; Carlson, Gordon; Warhurst, Geoffrey

    2011-01-01

    Background There is growing interest in the potential utility of real-time PCR in diagnosing bloodstream infection by detecting pathogen DNA in blood samples within a few hours. SeptiFast is a multipathogen probe-based real-time PCR system targeting ribosomal DNA sequences of bacteria and fungi. It detects and identifies the commonest pathogens causing bloodstream infection and has European regulatory approval. The SeptiFast pathogen panel is suited to identifying healthcare-associated bloodstream infection acquired during complex healthcare, and the authors report here the protocol for the first detailed health-technology assessment of multiplex real-time PCR in this setting. Methods/design A Phase III multicentre double-blinded diagnostic study will determine the clinical validity of SeptiFast for the rapid detection of healthcare-associated bloodstream infection, against the current service standard of microbiological culture, in an adequately sized population of critically ill adult patients. Results from SeptiFast and standard microbiological culture procedures in each patient will be compared at study conclusion and the metrics of clinical diagnostic accuracy of SeptiFast determined in this population setting. In addition, this study aims to assess further the preliminary evidence that the detection of pathogen DNA in the bloodstream using SeptiFast may have value in identifying the presence of infection elsewhere in the body. Furthermore, differences in circulating immune-inflammatory markers in patient groups differentiated by the presence/absence of culturable pathogens and pathogen DNA will help elucidate further the patho-physiology of infection developing in the critically ill. Ethics and dissemination Ethical approval has been granted by the North West 6 Research Ethics Committee (09/H1003/109). Based on the results of this first non-commercial study, independent recommendations will be made to The Department of Health (open-access health technology assessment report) as to whether SeptiFast has sufficient clinical diagnostic accuracy to move forward to efficacy testing during the provision of routine clinical care. PMID:22021785

  15. Fast neutron dosemeter using pixelated detector Timepix.

    PubMed

    Bulanek, Boris; Ekendahl, Daniela; Prouza, Zdenek

    2014-10-01

    A Timepix detector covered with polyethylene convertors of different thicknesses is presented as a fast neutron real-time dosemeter. The application of different weighting factors in connection with the position of a signal in a Timepix detector enables one to obtain an energy-dependent signal equal to neutron dose equivalents. A simulation of a Timepix detector covered with polyethylene convertors using monoenergetic neutrons is presented. The experimental set-up of a dosemeter was also produced. The first results of detector response using different fast neutron sources are presented. © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Soft x-ray continuum radiation transmitted through metallic filters: an analytical approach to fast electron temperature measurements.

    PubMed

    Delgado-Aparicio, L; Tritz, K; Kramer, T; Stutman, D; Finkenthal, M; Hill, K; Bitter, M

    2010-10-01

    A new set of analytic formulas describes the transmission of soft x-ray continuum radiation through a metallic foil for its application to fast electron temperature measurements in fusion plasmas. This novel approach shows good agreement with numerical calculations over a wide range of plasma temperatures in contrast with the solutions obtained when using a transmission approximated by a single-Heaviside function [S. von Goeler et al., Rev. Sci. Instrum. 70, 599 (1999)]. The new analytic formulas can improve the interpretation of the experimental results and thus contribute in obtaining fast temperature measurements in between intermittent Thomson scattering data.

  17. Fast Setting Silk Fibroin Bioink for Bioprinting of Patient-Specific Memory-Shape Implants.

    PubMed

    Costa, João B; Silva-Correia, Joana; Oliveira, Joaquim M; Reis, Rui L

    2017-11-01

    The pursuit for the "perfect" biomimetic and personalized implant for musculoskeletal tissue regeneration remains a big challenge. 3D printing technology that makes use of a novel and promising biomaterials can be part of the solution. In this study, a fast setting enzymatic-crosslinked silk fibroin (SF) bioink for 3D bioprinting is developed. Their properties are fine-tuned and different structures with good resolution, reproducibility, and reliability can be fabricated. Many potential applications exist for the SF bioinks including 3D bioprinted scaffolds and patient-specific implants exhibiting unique characteristics such as good mechanical properties, memory-shape feature, suitable degradation, and tunable pore architecture and morphology. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. a Fast Segmentation Algorithm for C-V Model Based on Exponential Image Sequence Generation

    NASA Astrophysics Data System (ADS)

    Hu, J.; Lu, L.; Xu, J.; Zhang, J.

    2017-09-01

    For the island coastline segmentation, a fast segmentation algorithm for C-V model method based on exponential image sequence generation is proposed in this paper. The exponential multi-scale C-V model with level set inheritance and boundary inheritance is developed. The main research contributions are as follows: 1) the problems of the "holes" and "gaps" are solved when extraction coastline through the small scale shrinkage, low-pass filtering and area sorting of region. 2) the initial value of SDF (Signal Distance Function) and the level set are given by Otsu segmentation based on the difference of reflection SAR on land and sea, which are finely close to the coastline. 3) the computational complexity of continuous transition are successfully reduced between the different scales by the SDF and of level set inheritance. Experiment results show that the method accelerates the acquisition of initial level set formation, shortens the time of the extraction of coastline, at the same time, removes the non-coastline body part and improves the identification precision of the main body coastline, which automates the process of coastline segmentation.

  19. Classification of Normal and Apoptotic Cells from Fluorescence Microscopy Images Using Generalized Polynomial Chaos and Level Set Function.

    PubMed

    Du, Yuncheng; Budman, Hector M; Duever, Thomas A

    2016-06-01

    Accurate automated quantitative analysis of living cells based on fluorescence microscopy images can be very useful for fast evaluation of experimental outcomes and cell culture protocols. In this work, an algorithm is developed for fast differentiation of normal and apoptotic viable Chinese hamster ovary (CHO) cells. For effective segmentation of cell images, a stochastic segmentation algorithm is developed by combining a generalized polynomial chaos expansion with a level set function-based segmentation algorithm. This approach provides a probabilistic description of the segmented cellular regions along the boundary, from which it is possible to calculate morphological changes related to apoptosis, i.e., the curvature and length of a cell's boundary. These features are then used as inputs to a support vector machine (SVM) classifier that is trained to distinguish between normal and apoptotic viable states of CHO cell images. The use of morphological features obtained from the stochastic level set segmentation of cell images in combination with the trained SVM classifier is more efficient in terms of differentiation accuracy as compared with the original deterministic level set method.

  20. Whisker Contact Detection of Rodents Based on Slow and Fast Mechanical Inputs

    PubMed Central

    Claverie, Laure N.; Boubenec, Yves; Debrégeas, Georges; Prevost, Alexis M.; Wandersman, Elie

    2017-01-01

    Rodents use their whiskers to locate nearby objects with an extreme precision. To perform such tasks, they need to detect whisker/object contacts with a high temporal accuracy. This contact detection is conveyed by classes of mechanoreceptors whose neural activity is sensitive to either slow or fast time varying mechanical stresses acting at the base of the whiskers. We developed a biomimetic approach to separate and characterize slow quasi-static and fast vibrational stress signals acting on a whisker base in realistic exploratory phases, using experiments on both real and artificial whiskers. Both slow and fast mechanical inputs are successfully captured using a mechanical model of the whisker. We present and discuss consequences of the whisking process in purely mechanical terms and hypothesize that free whisking in air sets a mechanical threshold for contact detection. The time resolution and robustness of the contact detection strategies based on either slow or fast stress signals are determined. Contact detection based on the vibrational signal is faster and more robust to exploratory conditions than the slow quasi-static component, although both slow/fast components allow localizing the object. PMID:28119582

  1. Sleep, Wakefulness and Circadian Rhythm

    DTIC Science & Technology

    1979-09-01

    School, Monterey, Calif., USA (1976): For 70 days,information processing Vas followed in 3 sub- jects; the set of performance data was subjected to Fast ...These include stress, hypoglycemia, suckling in post partum -1omen, strenuous excercise and a number of psychotropic drugs. However, L-DOPA administered...Psychiat. 28:19-24, 1973. 17. Quabbe. H.J., Schulling, E. and ilelge, H.: Pattern of growth hormone secretion during a 24 hour fast in normal adults. 3

  2. FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Joseph; Pirrung, Meg; McCue, Lee Ann

    FQC is software that facilitates quality control of FASTQ files by carrying out a QC protocol using FastQC, parsing results, and aggregating quality metrics into an interactive dashboard designed to richly summarize individual sequencing runs. The dashboard groups samples in dropdowns for navigation among the data sets, utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data.

  3. FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool

    DOE PAGES

    Brown, Joseph; Pirrung, Meg; McCue, Lee Ann

    2017-06-09

    FQC is software that facilitates quality control of FASTQ files by carrying out a QC protocol using FastQC, parsing results, and aggregating quality metrics into an interactive dashboard designed to richly summarize individual sequencing runs. The dashboard groups samples in dropdowns for navigation among the data sets, utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data.

  4. Sensor and Methodology for Dielectric Analysis of Vegetal Oils Submitted to Thermal Stress

    PubMed Central

    Stevan, Sergio Luiz; Paiter, Leandro; Ricardo Galvão, José; Vieira Roque, Daniely; Sidinei Chaves, Eduardo

    2015-01-01

    Vegetable oils used in frying food represent a social problem as its destination. The residual oil can be recycled and returned to the production line, as biodiesel, as soap, or as putty. The state of the residual oil is determined according to their physicochemical characteristics whose values define its economically viable destination. However, the physicochemical analysis requires high costs, time and general cost of transporting. This study presents the use of a capacitive sensor and a quick and inexpensive method to correlate the physicochemical variables to the dielectric constant of the material undergoing oil samples to thermal cycling. The proposed method allows reducing costs in the characterization of residual oil and the reduction in analysis time. In addition, the method allows an assessment of the quality of the vegetable oil during use. The experimental results show the increasing of the dielectric constant with the temperature, which facilitates measurement and classification of the dielectric constant at considerably higher temperatures. The results also confirm a definitive degradation in used oil and a correlation between the dielectric constant of the sample with the results of the physicochemical analysis (iodine value, acid value, viscosity and refractive index). PMID:26501293

  5. Sensor and methodology for dielectric analysis of vegetal oils submitted to thermal stress.

    PubMed

    Stevan, Sergio Luiz; Paiter, Leandro; Galvão, José Ricardo; Roque, Daniely Vieira; Chaves, Eduardo Sidinei

    2015-10-16

    Vegetable oils used in frying food represent a social problem as its destination. The residual oil can be recycled and returned to the production line, as biodiesel, as soap, or as putty. The state of the residual oil is determined according to their physicochemical characteristics whose values define its economically viable destination. However, the physicochemical analysis requires high costs, time and general cost of transporting. This study presents the use of a capacitive sensor and a quick and inexpensive method to correlate the physicochemical variables to the dielectric constant of the material undergoing oil samples to thermal cycling. The proposed method allows reducing costs in the characterization of residual oil and the reduction in analysis time. In addition, the method allows an assessment of the quality of the vegetable oil during use. The experimental results show the increasing of the dielectric constant with the temperature, which facilitates measurement and classification of the dielectric constant at considerably higher temperatures. The results also confirm a definitive degradation in used oil and a correlation between the dielectric constant of the sample with the results of the physicochemical analysis (iodine value, acid value, viscosity and refractive index).

  6. Inexpensive anatomical trainer for bronchoscopy.

    PubMed

    Di Domenico, Stefano; Simonassi, Claudio; Chessa, Leonardo

    2007-08-01

    Flexible fiberoptic bronchoscopy is an indispensable tool for optimal management of intensive care unit patients. However, the acquisition of sufficient training in bronchoscopy is not straightforward during residency, because of technical and ethical problems. Moreover, the use of commercial simulators is limited by their high cost. In order to overcome these limitations, we realized a low-cost anatomical simulator to acquire and maintain the basic skill to perform bronchoscopy in ventilated patients. We used 1.5 mm diameter iron wire to construct the bronchial tree scaffold; glazier-putty was applied to create the anatomical model. The model was covered by several layers of newspaper strips previously immersed in water and vinilic glue. When the model completely dried up, it was detached from the scaffold by cutting it into six pieces, it was reassembled, painted and fitted with an endotracheal tube. We used very cheap material and the final cost was euro16. The trainer resulted in real-scale and anatomically accurate, with appropriate correspondence on endoscopic view between model and patients. All bronchial segments can be explored and easily identified by endoscopic and external vision. This cheap simulator is a valuable tool for practicing, particularly in a hospital with limited resources for medical training.

  7. First measurements of Dα spectrum produced by anisotropic fast ions in the gas dynamic trap

    NASA Astrophysics Data System (ADS)

    Lizunov, A.; Anikeev, A.

    2014-11-01

    Angled injection of eight deuterium beams in gas dynamic trap (GDT) plasmas builds up the population of fast ions with the distribution function, which conserves a high degree of initial anisotropy in space, energy, and pitch angle. Unlike the Maxwellian distribution case, the fast ion plasma component in GDT cannot be exhaustively characterized by the temperature and density. The instrumentation complex to study of fast ions is comprised of motional Stark effect diagnostic, analyzers of charge exchange atoms, and others. The set of numerical codes using for equilibrium modeling is also an important tool of analysis. In the recent campaign of summer 2014, we recorded first signals from the new fast ion D-alpha diagnostic on GDT. This paper presents the diagnostic description and results of pilot measurements. The diagnostic has four lines of sight, distributed across the radius of an axially symmetric plasma column in GDT. In the present setup, a line-integrated optical signal is measured in each channel. In the transverse direction, the spatial resolution is 18 mm. Collected light comes to the grating spectrometer with the low-noise detector based on a charge-coupled device matrix. In the regime of four spectra stacked vertically on the sensor, the effective spectral resolution of measurements is approximately 0.015 nm. Exposure timing is provided by the fast optical ferroelectric crystal shutter, allowing frames of duration down to 70 μs. This number represents the time resolution of measurements. A large dynamic range of the camera permits for a measurement of relatively small light signals produced by fast ions on top of the bright background emission from the bulk plasma. The fast ion emission has a non-Gaussian spectrum featuring the characteristic width of approximately 4 nm, which can be separated from relatively narrow Gaussian lines of D-alpha and H-alpha coming from the plasma periphery, and diagnostic beam emission. The signal to noise ratio varies from approximately ten for the central channel to approximately five for the outermost channel. We used the special set of Monte Carlo codes to fit the measured spectra. The shape of model fit shows a good agreement with the experimental fast ion D-alpha spectrum.

  8. Experiences of Fast Queue health care users in primary health care facilities in eThekwini district, South Africa.

    PubMed

    Sokhela, Dudu G; Makhanya, Nonhlanhla J; Sibiya, Nokuthula M; Nokes, Kathleen M

    2013-07-05

    Comprehensive Primary Health Care (PHC), based on the principles of accessibility, availability, affordability, equity and acceptability, was introduced in South Africa to address inequalities in health service provision. Whilst the Fast Queue was instrumental in the promotion of access to health care, a major goal of the PHC approach, facilities were not prepared for the sudden influx of clients. Increased access resulted in long waiting times and queues contributing to dissatisfaction with the service which could lead to missed appointments and non-compliance with established treatment plans. Firstly to describe the experiences of clients using the Fast Queue strategy to access routine healthcare services and secondly, to determine how the clients' experiences led to satisfaction or dissatisfaction with the Fast Queue service. A descriptive qualitative survey using content analysis explored the experiences of the Fast Queue users in a PHC setting. Setting was first identified based on greatest number using the Fast Queue and geographic diversity and then a convenience sample of health care users of the Fast Queue were sampled individually along with one focus group of users who accessed the Queue monthly for medication refills. The same interview guide questions were used for both individual interviews and the one focus group discussion. Five clinics with the highest number of attendees during a three month period and a total of 83 health care users of the Fast Queue were interviewed. The average participant was female, 31 years old, single and unemployed. Two themes with sub-themes emerged: health care user flow and communication, which highlights both satisfaction and dissatisfaction with the fast queue and queue marshals, could assist in directing users to the respective queues, reduce waiting time and keep users satisfied with the use of sign posts where there is a lack of human resources. Effective health communication strategies contribute to positive experiences by health care users and these can be effected by: (1) involvement of health care providers in planning the construction of health facilities to give input about patient flow, infection prevention and control and provision of privacy, (2) effective complaints mechanisms for users to ensure that complaints are followed up and (3)encouraging users to arrive at the facility throughout the day, rather than the present practice where all users arrive at the clinic early in the morning.

  9. Fast Responding Oxygen Sensor For Respiratorial Analysis

    NASA Astrophysics Data System (ADS)

    Karpf, Hellfried H.; Kroneis, H. W.; Marsoner, Hermann J.; Metzler, H.; Gravenstein, N.

    1990-02-01

    Breath-by-breath monitoring of the partial pressure of oxygen is the main interest for the development of a fast responding optical oxygen sensor. Monitoring the P02 finds its main interest in critical care, in artificial respiration, in breath by breath determination of respiratorial coefficients and in pulmonarial examinations. The requirements arising from these and similar applications are high precision, high long term stability, and time constants in the range of less than 0.1 sec. In order to cope with these requirements, we investigated different possibilities of fast P02-measurements by means of optical sensors based on fluorescence quenching. The experimental set up is simple: a rigid transparent layer is coated with a thin layer of an hydrophobic polymer which has a high permeability for oxygen. The oxygen sensitive indicator material is embedded into this polymer. An experimental set up showed time constants of 30 milliseconds. The lifetime is in the range of several months. Testing of our test equipment by an independent working group resulted in surprisingly good correlation with data obtained by mass spectroscopy.

  10. Measurement, modeling, and simulation of cryogenic SiGe HBT amplifier circuits for fast single spin readout

    NASA Astrophysics Data System (ADS)

    England, Troy; Curry, Matthew; Carr, Steve; Swartzentruber, Brian; Lilly, Michael; Bishop, Nathan; Carrol, Malcolm

    2015-03-01

    Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout of electrons bound to Si:P donors. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance typical of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will discuss calibration data, as well as modeling and simulation of cryogenic silicon-germanium (SiGe) heterojunction bipolar transistor (HBT) circuits connected to a silicon SET and operating at 4 K. We find a continuum of solutions from simple, single-HBT amplifiers to more complex, multi-HBT circuits suitable for integration, with varying noise levels and power vs. bandwidth tradeoffs. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000.

  11. A fast learning method for large scale and multi-class samples of SVM

    NASA Astrophysics Data System (ADS)

    Fan, Yu; Guo, Huiming

    2017-06-01

    A multi-class classification SVM(Support Vector Machine) fast learning method based on binary tree is presented to solve its low learning efficiency when SVM processing large scale multi-class samples. This paper adopts bottom-up method to set up binary tree hierarchy structure, according to achieved hierarchy structure, sub-classifier learns from corresponding samples of each node. During the learning, several class clusters are generated after the first clustering of the training samples. Firstly, central points are extracted from those class clusters which just have one type of samples. For those which have two types of samples, cluster numbers of their positive and negative samples are set respectively according to their mixture degree, secondary clustering undertaken afterwards, after which, central points are extracted from achieved sub-class clusters. By learning from the reduced samples formed by the integration of extracted central points above, sub-classifiers are obtained. Simulation experiment shows that, this fast learning method, which is based on multi-level clustering, can guarantee higher classification accuracy, greatly reduce sample numbers and effectively improve learning efficiency.

  12. VUV absorption spectroscopy measurements of the role of fast neutral atoms in a high-power gap breakdown

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Filuk, A. B.; Bailey, J. E.; Cuneo, M. E.

    The maximum power achieved in a wide variety of high-power devices, including electron and ion diodes, z pinches, and microwave generators, is presently limited by anode-cathode gap breakdown. A frequently discussed hypothesis for this effect is ionization of fast neutral atoms injected throughout the anode-cathode gap during the power pulse. We describe a newly developed diagnostic tool that provides a direct test of this hypothesis. Time-resolved vacuum-ultraviolet absorption spectroscopy is used to directly probe fast neutral atoms with 1-mm spatial resolution in the 10-mm anode-cathode gap of the SABRE 5 MV, 1 TW applied-B ion diode. Absorption spectra collected duringmore » Ar RF glow discharges and with CO{sub 2} gas fills confirm the reliability of the diagnostic technique. Throughout the 50--100 ns ion diode pulses no measurable neutral absorption was seen, setting upper limits of (0.12--1.5)x10{sup 14}cm{sup -3} for ground-state fast neutral atom densities of H, C, N, O, and F. The absence of molecular absorption bands also sets upper limits of (0.16--1.2)x10{sup 15}cm{sup -3} for common simple molecules. These limits are low enough to rule out ionization of fast neutral atoms as a breakdown mechanism. Breakdown due to ionization of molecules is also found to be unlikely. This technique can now be applied to quantify the role of neutral atoms in other high-power devices.« less

  13. Basal Settings Control Fast Ice Flow in the Recovery/Slessor/Bailey Region, East Antarctica

    NASA Astrophysics Data System (ADS)

    Diez, Anja; Matsuoka, Kenichi; Ferraccioli, Fausto; Jordan, Tom A.; Corr, Hugh F.; Kohler, Jack; Olesen, Arne V.; Forsberg, René

    2018-03-01

    The region of Recovery Glacier, Slessor Glacier, and Bailey Ice Stream, East Antarctica, has remained poorly explored, despite representing the largest potential contributor to future global sea level rise on a centennial to millennial time scale. Here we use new airborne radar data to improve knowledge about the bed topography and investigate controls of fast ice flow. Recovery Glacier is underlain by an 800 km long trough. Its fast flow is controlled by subglacial water in its upstream and topography in its downstream region. Fast flow of Slessor Glacier is controlled by the presence of subglacial water on a rough crystalline bed. Past ice flow of adjacent Recovery and Slessor Glaciers was likely connected via the newly discovered Recovery-Slessor Gate. Changes in direction and speed of past fast flow likely occurred for upstream parts of Recovery Glacier and between Slessor Glacier and Bailey Ice Stream. Similar changes could also reoccur here in the future.

  14. Unsupervised, low latency anomaly detection of algorithmically generated domain names by generative probabilistic modeling.

    PubMed

    Raghuram, Jayaram; Miller, David J; Kesidis, George

    2014-07-01

    We propose a method for detecting anomalous domain names, with focus on algorithmically generated domain names which are frequently associated with malicious activities such as fast flux service networks, particularly for bot networks (or botnets), malware, and phishing. Our method is based on learning a (null hypothesis) probability model based on a large set of domain names that have been white listed by some reliable authority. Since these names are mostly assigned by humans, they are pronounceable, and tend to have a distribution of characters, words, word lengths, and number of words that are typical of some language (mostly English), and often consist of words drawn from a known lexicon. On the other hand, in the present day scenario, algorithmically generated domain names typically have distributions that are quite different from that of human-created domain names. We propose a fully generative model for the probability distribution of benign (white listed) domain names which can be used in an anomaly detection setting for identifying putative algorithmically generated domain names. Unlike other methods, our approach can make detections without considering any additional (latency producing) information sources, often used to detect fast flux activity. Experiments on a publicly available, large data set of domain names associated with fast flux service networks show encouraging results, relative to several baseline methods, with higher detection rates and low false positive rates.

  15. Synchronous-digitization for Video Rate Polarization Modulated Beam Scanning Second Harmonic Generation Microscopy.

    PubMed

    Sullivan, Shane Z; DeWalt, Emma L; Schmitt, Paul D; Muir, Ryan M; Simpson, Garth J

    2015-03-09

    Fast beam-scanning non-linear optical microscopy, coupled with fast (8 MHz) polarization modulation and analytical modeling have enabled simultaneous nonlinear optical Stokes ellipsometry (NOSE) and linear Stokes ellipsometry imaging at video rate (15 Hz). NOSE enables recovery of the complex-valued Jones tensor that describes the polarization-dependent observables, in contrast to polarimetry, in which the polarization stated of the exciting beam is recorded. Each data acquisition consists of 30 images (10 for each detector, with three detectors operating in parallel), each of which corresponds to polarization-dependent results. Processing of this image set by linear fitting contracts down each set of 10 images to a set of 5 parameters for each detector in second harmonic generation (SHG) and three parameters for the transmittance of the fundamental laser beam. Using these parameters, it is possible to recover the Jones tensor elements of the sample at video rate. Video rate imaging is enabled by performing synchronous digitization (SD), in which a PCIe digital oscilloscope card is synchronized to the laser (the laser is the master clock.) Fast polarization modulation was achieved by modulating an electro-optic modulator synchronously with the laser and digitizer, with a simple sine-wave at 1/10th the period of the laser, producing a repeating pattern of 10 polarization states. This approach was validated using Z-cut quartz, and NOSE microscopy was performed for micro-crystals of naproxen.

  16. Synchronous-digitization for video rate polarization modulated beam scanning second harmonic generation microscopy

    NASA Astrophysics Data System (ADS)

    Sullivan, Shane Z.; DeWalt, Emma L.; Schmitt, Paul D.; Muir, Ryan D.; Simpson, Garth J.

    2015-03-01

    Fast beam-scanning non-linear optical microscopy, coupled with fast (8 MHz) polarization modulation and analytical modeling have enabled simultaneous nonlinear optical Stokes ellipsometry (NOSE) and linear Stokes ellipsometry imaging at video rate (15 Hz). NOSE enables recovery of the complex-valued Jones tensor that describes the polarization-dependent observables, in contrast to polarimetry, in which the polarization stated of the exciting beam is recorded. Each data acquisition consists of 30 images (10 for each detector, with three detectors operating in parallel), each of which corresponds to polarization-dependent results. Processing of this image set by linear fitting contracts down each set of 10 images to a set of 5 parameters for each detector in second harmonic generation (SHG) and three parameters for the transmittance of the fundamental laser beam. Using these parameters, it is possible to recover the Jones tensor elements of the sample at video rate. Video rate imaging is enabled by performing synchronous digitization (SD), in which a PCIe digital oscilloscope card is synchronized to the laser (the laser is the master clock.) Fast polarization modulation was achieved by modulating an electro-optic modulator synchronously with the laser and digitizer, with a simple sine-wave at 1/10th the period of the laser, producing a repeating pattern of 10 polarization states. This approach was validated using Z-cut quartz, and NOSE microscopy was performed for micro-crystals of naproxen.

  17. Unsupervised, low latency anomaly detection of algorithmically generated domain names by generative probabilistic modeling

    PubMed Central

    Raghuram, Jayaram; Miller, David J.; Kesidis, George

    2014-01-01

    We propose a method for detecting anomalous domain names, with focus on algorithmically generated domain names which are frequently associated with malicious activities such as fast flux service networks, particularly for bot networks (or botnets), malware, and phishing. Our method is based on learning a (null hypothesis) probability model based on a large set of domain names that have been white listed by some reliable authority. Since these names are mostly assigned by humans, they are pronounceable, and tend to have a distribution of characters, words, word lengths, and number of words that are typical of some language (mostly English), and often consist of words drawn from a known lexicon. On the other hand, in the present day scenario, algorithmically generated domain names typically have distributions that are quite different from that of human-created domain names. We propose a fully generative model for the probability distribution of benign (white listed) domain names which can be used in an anomaly detection setting for identifying putative algorithmically generated domain names. Unlike other methods, our approach can make detections without considering any additional (latency producing) information sources, often used to detect fast flux activity. Experiments on a publicly available, large data set of domain names associated with fast flux service networks show encouraging results, relative to several baseline methods, with higher detection rates and low false positive rates. PMID:25685511

  18. FastSKAT: Sequence kernel association tests for very large sets of markers.

    PubMed

    Lumley, Thomas; Brody, Jennifer; Peloso, Gina; Morrison, Alanna; Rice, Kenneth

    2018-06-22

    The sequence kernel association test (SKAT) is widely used to test for associations between a phenotype and a set of genetic variants that are usually rare. Evaluating tail probabilities or quantiles of the null distribution for SKAT requires computing the eigenvalues of a matrix related to the genotype covariance between markers. Extracting the full set of eigenvalues of this matrix (an n×n matrix, for n subjects) has computational complexity proportional to n 3 . As SKAT is often used when n>104, this step becomes a major bottleneck in its use in practice. We therefore propose fastSKAT, a new computationally inexpensive but accurate approximations to the tail probabilities, in which the k largest eigenvalues of a weighted genotype covariance matrix or the largest singular values of a weighted genotype matrix are extracted, and a single term based on the Satterthwaite approximation is used for the remaining eigenvalues. While the method is not particularly sensitive to the choice of k, we also describe how to choose its value, and show how fastSKAT can automatically alert users to the rare cases where the choice may affect results. As well as providing faster implementation of SKAT, the new method also enables entirely new applications of SKAT that were not possible before; we give examples grouping variants by topologically associating domains, and comparing chromosome-wide association by class of histone marker. © 2018 WILEY PERIODICALS, INC.

  19. Compressibility of two polyvinyl siloxane interocclusal record materials and its effect on mounted cast relationships.

    PubMed

    Campos, A A; Nathanson, D

    1999-10-01

    Addition silicones (polyvinyl siloxanes) are universally accepted as accurate and stable impression materials. They have also gained popularity as interocclusal record materials. However, it has not been defined if it is possible to work with polyvinyl siloxanes without changing the recorded maxillomandibular relations. This study examined the compressibility of 2 addition silicones as interocclusal record materials, analyzing the changes of maxillomandibular relations at the condyle region when different compressive forces are used to stabilize articulated casts. Sixteen interocclusal records, obtained from the same patient (8 of each polyvinyl siloxane, Blu-Mousse, Fast Set), were interposed between the patient casts in a new measuring system obtaining 48 curves of load versus maxillomandibular positional changes in 3 axes (x, y, z). These curves were compared with curves obtained with the casts in maximum intercuspation without interocclusal records (reference curves). Analysis of variance was used to compare maxillomandibular positional changes among the 3 groups (n = 48 each): Blu-Mousse, Fast Set, and control group or maximum intercuspation without interocclusal record. There was no significant change in maxillomandibular relations when forces up to 1 kgf were applied to stabilize the casts related by means of Blu-Mousse and Fast Set addition silicone interocclusal records. It is possible to use these polyvinyl siloxanes as interocclusal record materials without changing the recorded maxillomandibular relations.

  20. Knowledge, beliefs and attitudes of Muslim footballers towards Ramadan fasting during the London 2012 Olympics: a cross-sectional study

    PubMed Central

    Herrera, Christopher P; Zerguini, Yacine; Almudahka, Fuad

    2016-01-01

    Objectives Muslims observe fasting during the month of Ramadan by abstaining from eating and drinking from dawn to sunset. Available literature shows that although several studies have been conducted on athletes to determine the effects of Ramadan fasting in terms of physical fitness and performance, little data are available regarding the knowledge, beliefs and attitudes of athletes (particularly footballers) towards Ramadan fasting during high-level competitions. This study explored the knowledge, beliefs and attitudes towards Ramadan fasting among football players participating in the London 2012 Olympics football tournament. Design Cross-sectional study. Settings Team training facility. Participants 54 Muslim footballers participating in the London Olympics, 2012 Outcome measures Each participant was asked to complete a pre-validated structured questionnaire to assess knowledge, beliefs and attitudes regarding Ramadan fasting and their intention to fast during London 2012. Results Of the 54 participating athletes, 21(39%) reported that they intended to fast during Ramadan, but not on a match day. This attitude differed across three teams interviewed —83%, 15% and 0%—showing cross-cultural variation. Overall, there was a lack of knowledge among footballers regarding the effects of Ramadan fasting on sleep and performance; around 30% of athletes gave incorrect responses. This knowledge was independent of their decision to fast on non-competition days (p>0.05). Conclusions This is the first study to describe the knowledge, beliefs and attitudes towards Ramadan fasting among athletes from Muslim-majority countries participating in a high-level competition. Appropriate knowledge can ensure optimum performance for athletes during Ramadan fasting. Coaches, family members and friends also in possession of this knowledge can provide moral support to the players. PMID:27670523

  1. Fast Track, Bush Track: Late Career Female Rural School Leaders Taking the Slow Road

    ERIC Educational Resources Information Center

    Miller, Judith; Graham, Lorraine; Al-Awiwe, Azhar

    2014-01-01

    Previous research related to this study explored early career female leaders' experiences in rural school settings, and probed the personal and professional challenges they faced and their motivations to accept formal and informal leadership roles ahead of the usual timeframes (e.g., Graham, Miller & Paterson, 2009). This study set out to…

  2. The Versatility of SpAM: A Fast, Efficient, Spatial Method of Data Collection for Multidimensional Scaling

    ERIC Educational Resources Information Center

    Hout, Michael C.; Goldinger, Stephen D.; Ferguson, Ryan W.

    2013-01-01

    Although traditional methods to collect similarity data (for multidimensional scaling [MDS]) are robust, they share a key shortcoming. Specifically, the possible pairwise comparisons in any set of objects grow rapidly as a function of set size. This leads to lengthy experimental protocols, or procedures that involve scaling stimulus subsets. We…

  3. States Adopt Standards at Fast Clip

    ERIC Educational Resources Information Center

    Gewertz, Catherine

    2010-01-01

    Nearly half the states have adopted a new set of common academic standards, barely a month after their final release and, in most cases, with little opposition. As of July 9, 23 states had decided to replace their mathematics and English/language arts standards with the common set. Another flurry of adoptions is expected by Aug. 2, since the $4…

  4. Eliminating fast reactions in stochastic simulations of biochemical networks: A bistable genetic switch

    NASA Astrophysics Data System (ADS)

    Morelli, Marco J.; Allen, Rosalind J.; Tǎnase-Nicola, Sorin; ten Wolde, Pieter Rein

    2008-01-01

    In many stochastic simulations of biochemical reaction networks, it is desirable to "coarse grain" the reaction set, removing fast reactions while retaining the correct system dynamics. Various coarse-graining methods have been proposed, but it remains unclear which methods are reliable and which reactions can safely be eliminated. We address these issues for a model gene regulatory network that is particularly sensitive to dynamical fluctuations: a bistable genetic switch. We remove protein-DNA and/or protein-protein association-dissociation reactions from the reaction set using various coarse-graining strategies. We determine the effects on the steady-state probability distribution function and on the rate of fluctuation-driven switch flipping transitions. We find that protein-protein interactions may be safely eliminated from the reaction set, but protein-DNA interactions may not. We also find that it is important to use the chemical master equation rather than macroscopic rate equations to compute effective propensity functions for the coarse-grained reactions.

  5. A Designers’ Guide to Reliable Distributed Systems: Design and Analysis Methods. An Example Design. Volume 1

    DTIC Science & Technology

    1988-08-01

    exchanged between the cells, thus requiring existence of fast , high capacity, high availability communication channels. The same arguments indicate...mininet - loss of a cell - intermittent communications failure in the maxinet - partitioning of the maxinet or the mininet o Query decomposition. 3.3...take place. A new sequencer is selected by the timeout mechanism described above. This process Pj must set its priority to 0 in order to ensure fast

  6. Correlation-coefficient-based fast template matching through partial elimination.

    PubMed

    Mahmood, Arif; Khan, Sohaib

    2012-04-01

    Partial computation elimination techniques are often used for fast template matching. At a particular search location, computations are prematurely terminated as soon as it is found that this location cannot compete with an already known best match location. Due to the nonmonotonic growth pattern of the correlation-based similarity measures, partial computation elimination techniques have been traditionally considered inapplicable to speed up these measures. In this paper, we show that partial elimination techniques may be applied to a correlation coefficient by using a monotonic formulation, and we propose basic-mode and extended-mode partial correlation elimination algorithms for fast template matching. The basic-mode algorithm is more efficient on small template sizes, whereas the extended mode is faster on medium and larger templates. We also propose a strategy to decide which algorithm to use for a given data set. To achieve a high speedup, elimination algorithms require an initial guess of the peak correlation value. We propose two initialization schemes including a coarse-to-fine scheme for larger templates and a two-stage technique for small- and medium-sized templates. Our proposed algorithms are exact, i.e., having exhaustive equivalent accuracy, and are compared with the existing fast techniques using real image data sets on a wide variety of template sizes. While the actual speedups are data dependent, in most cases, our proposed algorithms have been found to be significantly faster than the other algorithms.

  7. Generalized fast feedback system in the SLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hendrickson, L.; Allison, S.; Gromme, T.

    A generalized fast feedback system has been developed to stabilize beams at various locations in the SLC. The system is designed to perform measurements and change actuator settings to control beam states such as position, angle and energy on a pulse to pulse basis. The software design is based on the state space formalism of digital control theory. The system is database-driven, facilitating the addition of new loops without requiring additional software. A communications system, KISNet, provides fast communications links between microprocessors for feedback loops which involve multiple micros. Feedback loops have been installed in seventeen locations throughout the SLCmore » and have proven to be invaluable in stabilizing the machine.« less

  8. Automatic brain tumor segmentation with a fast Mumford-Shah algorithm

    NASA Astrophysics Data System (ADS)

    Müller, Sabine; Weickert, Joachim; Graf, Norbert

    2016-03-01

    We propose a fully-automatic method for brain tumor segmentation that does not require any training phase. Our approach is based on a sequence of segmentations using the Mumford-Shah cartoon model with varying parameters. In order to come up with a very fast implementation, we extend the recent primal-dual algorithm of Strekalovskiy et al. (2014) from the 2D to the medically relevant 3D setting. Moreover, we suggest a new confidence refinement and show that it can increase the precision of our segmentations substantially. Our method is evaluated on 188 data sets with high-grade gliomas and 25 with low-grade gliomas from the BraTS14 database. Within a computation time of only three minutes, we achieve Dice scores that are comparable to state-of-the-art methods.

  9. A1C as a Diagnostic Criteria for Diabetes in Low- and Middle-Income Settings: Evidence from Peru

    PubMed Central

    Miranda, J. Jaime; Bernabe-Ortiz, Antonio; Stanojevic, Sanja; Malaga, German; Gilman, Robert H.; Smeeth, Liam

    2011-01-01

    Objectives To determine the prevalence of type 2 diabetes mellitus, in three groups of Peruvian adults, using fasting glucose and glycosylated hemoglobin (A1C). Methodology/Principal Findings This study included adults from the PERU MIGRANT Study who had fasted ≥8 h. Fasting glucose ≥126 mg/dL and A1C≥6.5% were used, separately, to define diabetes. Subjects with a current diagnosis of diabetes were excluded. 964 of 988 subjects were included in this analysis. Overall, 0.9% (95%CI 0.3–1.5) and 3.5% (95%CI 2.4–4.7) had diabetes using fasting glucose and A1C criteria, respectively. Compared to those classified as having diabetes using fasting glucose, newly classified subjects with diabetes using A1C (n = 25), were older, poorer, thinner and more likely to come from rural areas. Of these, 40% (10/25) had impaired fasting glucose (IFG). Conclusions This study shows that the use of A1C as diagnostic criteria for type 2 diabetes mellitus identifies people of different characteristics than fasting glucose. In the PERU MIGRANT population using A1C to define diabetes tripled the prevalence; the increase was more marked among poorer and rural populations. More than half the newly diagnosed people with diabetes using A1C had normal fasting glucose. PMID:21464957

  10. A1C as a diagnostic criteria for diabetes in low- and middle-income settings: evidence from Peru.

    PubMed

    Miranda, J Jaime; Bernabe-Ortiz, Antonio; Stanojevic, Sanja; Malaga, German; Gilman, Robert H; Smeeth, Liam

    2011-03-25

    To determine the prevalence of type 2 diabetes mellitus, in three groups of Peruvian adults, using fasting glucose and glycosylated hemoglobin (A1C). This study included adults from the PERU MIGRANT Study who had fasted ≥ 8 h. Fasting glucose ≥ 126 mg/dL and A1C ≥ 6.5% were used, separately, to define diabetes. Subjects with a current diagnosis of diabetes were excluded. 964 of 988 subjects were included in this analysis. Overall, 0.9% (95%CI 0.3-1.5) and 3.5% (95%CI 2.4-4.7) had diabetes using fasting glucose and A1C criteria, respectively. Compared to those classified as having diabetes using fasting glucose, newly classified subjects with diabetes using A1C (n = 25), were older, poorer, thinner and more likely to come from rural areas. Of these, 40% (10/25) had impaired fasting glucose (IFG). This study shows that the use of A1C as diagnostic criteria for type 2 diabetes mellitus identifies people of different characteristics than fasting glucose. In the PERU MIGRANT population using A1C to define diabetes tripled the prevalence; the increase was more marked among poorer and rural populations. More than half the newly diagnosed people with diabetes using A1C had normal fasting glucose.

  11. Fast H-DROP: A thirty times accelerated version of H-DROP for interactive SVM-based prediction of helical domain linkers

    NASA Astrophysics Data System (ADS)

    Richa, Tambi; Ide, Soichiro; Suzuki, Ryosuke; Ebina, Teppei; Kuroda, Yutaka

    2017-02-01

    Efficient and rapid prediction of domain regions from amino acid sequence information alone is often required for swift structural and functional characterization of large multi-domain proteins. Here we introduce Fast H-DROP, a thirty times accelerated version of our previously reported H-DROP (Helical Domain linker pRediction using OPtimal features), which is unique in specifically predicting helical domain linkers (boundaries). Fast H-DROP, analogously to H-DROP, uses optimum features selected from a set of 3000 ones by combining a random forest and a stepwise feature selection protocol. We reduced the computational time from 8.5 min per sequence in H-DROP to 14 s per sequence in Fast H-DROP on an 8 Xeon processor Linux server by using SWISS-PROT instead of Genbank non-redundant (nr) database for generating the PSSMs. The sensitivity and precision of Fast H-DROP assessed by cross-validation were 33.7 and 36.2%, which were merely 2% lower than that of H-DROP. The reduced computational time of Fast H-DROP, without affecting prediction performances, makes it more interactive and user-friendly. Fast H-DROP and H-DROP are freely available from http://domserv.lab.tuat.ac.jp/.

  12. Failure of Standard Training Sets in the Analysis of Fast-Scan Cyclic Voltammetry Data.

    PubMed

    Johnson, Justin A; Rodeberg, Nathan T; Wightman, R Mark

    2016-03-16

    The use of principal component regression, a multivariate calibration method, in the analysis of in vivo fast-scan cyclic voltammetry data allows for separation of overlapping signal contributions, permitting evaluation of the temporal dynamics of multiple neurotransmitters simultaneously. To accomplish this, the technique relies on information about current-concentration relationships across the scan-potential window gained from analysis of training sets. The ability of the constructed models to resolve analytes depends critically on the quality of these data. Recently, the use of standard training sets obtained under conditions other than those of the experimental data collection (e.g., with different electrodes, animals, or equipment) has been reported. This study evaluates the analyte resolution capabilities of models constructed using this approach from both a theoretical and experimental viewpoint. A detailed discussion of the theory of principal component regression is provided to inform this discussion. The findings demonstrate that the use of standard training sets leads to misassignment of the current-concentration relationships across the scan-potential window. This directly results in poor analyte resolution and, consequently, inaccurate quantitation, which may lead to erroneous conclusions being drawn from experimental data. Thus, it is strongly advocated that training sets be obtained under the experimental conditions to allow for accurate data analysis.

  13. Integrative Functional Genomics for Systems Genetics in GeneWeaver.org.

    PubMed

    Bubier, Jason A; Langston, Michael A; Baker, Erich J; Chesler, Elissa J

    2017-01-01

    The abundance of existing functional genomics studies permits an integrative approach to interpreting and resolving the results of diverse systems genetics studies. However, a major challenge lies in assembling and harmonizing heterogeneous data sets across species for facile comparison to the positional candidate genes and coexpression networks that come from systems genetic studies. GeneWeaver is an online database and suite of tools at www.geneweaver.org that allows for fast aggregation and analysis of gene set-centric data. GeneWeaver contains curated experimental data together with resource-level data such as GO annotations, MP annotations, and KEGG pathways, along with persistent stores of user entered data sets. These can be entered directly into GeneWeaver or transferred from widely used resources such as GeneNetwork.org. Data are analyzed using statistical tools and advanced graph algorithms to discover new relations, prioritize candidate genes, and generate function hypotheses. Here we use GeneWeaver to find genes common to multiple gene sets, prioritize candidate genes from a quantitative trait locus, and characterize a set of differentially expressed genes. Coupling a large multispecies repository curated and empirical functional genomics data to fast computational tools allows for the rapid integrative analysis of heterogeneous data for interpreting and extrapolating systems genetics results.

  14. Combining Fast-Walking Training and a Step Activity Monitoring Program to Improve Daily Walking Activity After Stroke: A Preliminary Study.

    PubMed

    Danks, Kelly A; Pohlig, Ryan; Reisman, Darcy S

    2016-09-01

    To determine preliminary efficacy and to identify baseline characteristics predicting who would benefit most from fast walking training plus a step activity monitoring program (FAST+SAM) compared with fast walking training (FAST) alone in persons with chronic stroke. Randomized controlled trial with blinded assessors. Outpatient clinical research laboratory. Individuals (N=37) >6 months poststroke. Subjects were assigned to either FAST, which was walking training at their fastest possible speed on the treadmill (30min) and overground 3 times per week for 12 weeks, or FAST+SAM. The step activity monitoring program consisted of daily step monitoring with an activity monitor, goal setting, and identification of barriers to activity and strategies to overcome barriers. Daily step activity metrics (steps/day [SPD], time walking per day), walking speed, and 6-minute walk test (6MWT) distance. There was a significant effect of time for both groups, with all outcomes improving from pre- to posttraining (all P values <.05). The FAST+SAM was superior to FAST for 6MWT (P=.018), with a larger increase in the FAST+SAM group. The interventions had differential effectiveness based on baseline step activity. Sequential moderated regression models demonstrated that for subjects with baseline levels of step activity and 6MWT distances that were below the mean, the FAST+SAM intervention was more effective than FAST (1715±1584 vs 254±933 SPD; P<.05 for overall model and ΔR(2) for SPD and 6MWT). The addition of a step activity monitoring program to a fast walking training intervention may be most effective in persons with chronic stroke who have initial low levels of walking endurance and activity. Regardless of baseline performance, the FAST+SAM intervention was more effective for improving walking endurance. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  15. The Field Assessment Stroke Triage for Emergency Destination (FAST-ED): a Simple and Accurate Pre-Hospital Scale to Detect Large Vessel Occlusion Strokes

    PubMed Central

    Lima, Fabricio O.; Silva, Gisele S.; Furie, Karen L.; Frankel, Michael R.; Lev, Michael H.; Camargo, Érica CS; Haussen, Diogo C.; Singhal, Aneesh B.; Koroshetz, Walter J.; Smith, Wade S.; Nogueira, Raul G.

    2016-01-01

    Background and Purpose Patients with large vessel occlusion strokes (LVOS) may be better served by direct transfer to endovascular capable centers avoiding hazardous delays between primary and comprehensive stroke centers. However, accurate stroke field triage remains challenging. We aimed to develop a simple field scale to identify LVOS. Methods The FAST-ED scale was based on items of the NIHSS with higher predictive value for LVOS and tested in the STOPStroke cohort, in which patients underwent CT angiography within the first 24 hours of stroke onset. LVOS were defined by total occlusions involving the intracranial-ICA, MCA-M1, MCA-2, or basilar arteries. Patients with partial, bi-hemispheric, and/or anterior + posterior circulation occlusions were excluded. Receiver operating characteristic (ROC) curve, sensitivity, specificity, positive (PPV) and negative predictive values (NPV) of FAST-ED were compared with the NIHSS, Rapid Arterial oCclusion Evaluation (RACE) scale and Cincinnati Prehospital Stroke Severity Scale (CPSSS). Results LVO was detected in 240 of the 727 qualifying patients (33%). FAST-ED had comparable accuracy to predict LVO to the NIHSS and higher accuracy than RACE and CPSS (area under the ROC curve: FAST-ED=0.81 as reference; NIHSS=0.80, p=0.28; RACE=0.77, p=0.02; and CPSS=0.75, p=0.002). A FAST-ED ≥4 had sensitivity of 0.60, specificity 0.89, PPV 0.72, and NPV 0.82 versus RACE ≥5 of 0.55, 0.87, 0.68, 0.79 and CPSS ≥2 of 0.56, 0.85, 0.65, 0.78, respectively. Conclusions FAST-ED is a simple scale that if successfully validated in the field may be used by medical emergency professionals to identify LVOS in the pre-hospital setting enabling rapid triage of patients. PMID:27364531

  16. Fiber-Optic Array Scanning Technology (FAST) for Detection and Molecular Characterization of Circulating Tumor Cells.

    PubMed

    Ao, Zheng; Liu, Xiaohe

    2017-01-01

    Circulating tumor cell (CTC) as an important component in "liquid biopsy" holds crucial clinical relevance in cancer prognosis, treatment efficiency evaluation, prediction and potentially early detection. Here, we present a Fiber-optic Array Scanning Technology (FAST) that enables antigen-agnostic, size-agnostic detection of CTC. By immunofluorescence staining detection of a combination of a panel of markers, FAST technology can be applied to detect rare CTC in non-small cell lung cancer (NSCLC) setting with high sensitivity and specificity. In combination with Automated Digital Microscopy (ADM) platform, companion markers on CTC such as Vimentin and Programmed death-ligand 1 (PD-L1) can also be analyzed to further characterize these CTCs. FAST data output is also compatible with downstream single cell picking platforms. Single cell can be isolated post ADM confirmation and used for "actionable" genetic mutations analysis.

  17. Automatic building detection based on Purposive FastICA (PFICA) algorithm using monocular high resolution Google Earth images

    NASA Astrophysics Data System (ADS)

    Ghaffarian, Saman; Ghaffarian, Salar

    2014-11-01

    This paper proposes an improved FastICA model named as Purposive FastICA (PFICA) with initializing by a simple color space transformation and a novel masking approach to automatically detect buildings from high resolution Google Earth imagery. ICA and FastICA algorithms are defined as Blind Source Separation (BSS) techniques for unmixing source signals using the reference data sets. In order to overcome the limitations of the ICA and FastICA algorithms and make them purposeful, we developed a novel method involving three main steps: 1-Improving the FastICA algorithm using Moore-Penrose pseudo inverse matrix model, 2-Automated seeding of the PFICA algorithm based on LUV color space and proposed simple rules to split image into three regions; shadow + vegetation, baresoil + roads and buildings, respectively, 3-Masking out the final building detection results from PFICA outputs utilizing the K-means clustering algorithm with two number of clusters and conducting simple morphological operations to remove noises. Evaluation of the results illustrates that buildings detected from dense and suburban districts with divers characteristics and color combinations using our proposed method have 88.6% and 85.5% overall pixel-based and object-based precision performances, respectively.

  18. [The fasting calcium/creatinine ratio in patients with calcium stones and the relation with hypercalciuria and phosphocalcium metabolism].

    PubMed

    Arrabal-Polo, Miguel Ángel; del Carmen Cano-García, María; Arrabal-Martín, Miguel

    2016-04-01

    To determine the importance of fasting calcium/creatinine ratio in patients with calcium stones and its relation with hypercalciuria and phospho-calcium metabolism. Cross-sectional study including 143 patients divided into two groups according to fasting calcium/creatinine. Group 1: 66 patients (calcium/ creatinine<0.11); Group 2: 77 patients (calcium/ creatinine>0.11). A comparative study is performed between groups including phospho-calcium metabolism parameters and excretion of urinary lithogenic markers. Linear correlation studying calciuria and fasting calcium/ creatinine was performed. SPSS 17.0 statistical analysis software was used, considering p≤0.05. It is noteworthy that group 2 had increased 24 h urine calcium excretion in comparison to group 1 (229.3 vs 158.1; p=0.0001) and calcium/citrate (0.47 vs 0.34; p=0.001). There is a positive and significant correlation between calcium levels in 24 h urine and fasting calcium/creatinine (R=0.455; p=0.0001) and a cutoff is set at 0.127 (sensitivity 72%, specificity 66%) to determine hypercalciuria (>260 mg in 24 h). Increased fasting calcium/creatinine determines increased 24 hours calcium excretion, although the sensitivity and specificity to determine hypercalciuria is not high.

  19. Discrete Radon transform has an exact, fast inverse and generalizes to operations other than sums along lines

    PubMed Central

    Press, William H.

    2006-01-01

    Götz, Druckmüller, and, independently, Brady have defined a discrete Radon transform (DRT) that sums an image's pixel values along a set of aptly chosen discrete lines, complete in slope and intercept. The transform is fast, O(N2log N) for an N × N image; it uses only addition, not multiplication or interpolation, and it admits a fast, exact algorithm for the adjoint operation, namely backprojection. This paper shows that the transform additionally has a fast, exact (although iterative) inverse. The inverse reproduces to machine accuracy the pixel-by-pixel values of the original image from its DRT, without artifacts or a finite point-spread function. Fourier or fast Fourier transform methods are not used. The inverse can also be calculated from sampled sinograms and is well conditioned in the presence of noise. Also introduced are generalizations of the DRT that combine pixel values along lines by operations other than addition. For example, there is a fast transform that calculates median values along all discrete lines and is able to detect linear features at low signal-to-noise ratios in the presence of pointlike clutter features of arbitrarily large amplitude. PMID:17159155

  20. Discrete Radon transform has an exact, fast inverse and generalizes to operations other than sums along lines.

    PubMed

    Press, William H

    2006-12-19

    Götz, Druckmüller, and, independently, Brady have defined a discrete Radon transform (DRT) that sums an image's pixel values along a set of aptly chosen discrete lines, complete in slope and intercept. The transform is fast, O(N2log N) for an N x N image; it uses only addition, not multiplication or interpolation, and it admits a fast, exact algorithm for the adjoint operation, namely backprojection. This paper shows that the transform additionally has a fast, exact (although iterative) inverse. The inverse reproduces to machine accuracy the pixel-by-pixel values of the original image from its DRT, without artifacts or a finite point-spread function. Fourier or fast Fourier transform methods are not used. The inverse can also be calculated from sampled sinograms and is well conditioned in the presence of noise. Also introduced are generalizations of the DRT that combine pixel values along lines by operations other than addition. For example, there is a fast transform that calculates median values along all discrete lines and is able to detect linear features at low signal-to-noise ratios in the presence of pointlike clutter features of arbitrarily large amplitude.

  1. Ultra-Low Loss, Chip-Based Hollow-Core Waveguide Using High-Contrast Grating

    DTIC Science & Technology

    2011-09-28

    Although the physical mechanism for tuning the filter may allow fast tuning, the tap weight computational algorithm must also be fast enough to support...applications and the ability to accurately set tap weights through optical splitting and combining networks is important. Techniques for trimming and...are: h(t)=s*(-t) and H(OJ)=S*(-OJ), respectively. Then the tap weights and delays should be chosen as: tk=kLJt and ak=h(tll)=s*(-tk), respectively

  2. Analog synthesized fast-variable linear load

    NASA Technical Reports Server (NTRS)

    Niedra, Janis M.

    1991-01-01

    A several kilowatt power level, fast-variable linear resistor was synthesized by using analog components to control the conductance of power MOSFETs. Risetimes observed have been as short as 500 ns with respect to the control signal and 1 to 2 microseconds with respect to the power source voltage. A variant configuration of this load that dissipates a constant power set by a control signal is indicated. Replacement of the MOSFETs by static induction transistors (SITs) to increase power handling, speed and radiation hardness is discussed.

  3. A fast Karhunen-Loeve transform for a class of random processes

    NASA Technical Reports Server (NTRS)

    Jain, A. K.

    1976-01-01

    It is shown that for a class of finite first-order Markov signals, the Karhunen-Loeve (KL) transform for data compression is a set of periodic sine functions if the boundary values of the signal are fixed or known. These sine functions are shown to be related to the Fourier transform so that a fast Fourier transform algorithm can be used to implement the KL transform. Extension to two dimensions with reference to images with separable contravariance function is shown.

  4. Implementation and simulations of the sphere solution in FAST

    NASA Astrophysics Data System (ADS)

    Murgolo, F. P.; Schirone, M. G.; Lattanzi, M.; Bernacca, P. L.

    1989-06-01

    The details of the implementation of the sphere solution software in the Fundamental Astronomy by Space Techniques (FAST) consortium, are described. The simulation results for realistic data sets, both with and without grid-step errors are given. Expected errors on the astrometric parameters of the primary stars and the precision of the reference great circle zero points, are provided as a function of mission duration. The design matrix, the diagrams of the context processor and the processors experimental results are given.

  5. Suggestions for getting more forestry in the logging plan.

    Treesearch

    Robert H. Ruth; Roy R. Silen

    1950-01-01

    The staggered-setting system of clear-cutting is fast becoming prevailing practice in the Douglas-fir region. The trend is away from large, continuous clear cuts to clear-cutting smaller units of timber of less than 80 acres. These are called staggered settings because the surrounding stand is left uncut to provide seed and serve as a firebreak. Major aims of this...

  6. Dynamical scales for multi-TeV top-pair production at the LHC

    NASA Astrophysics Data System (ADS)

    Czakon, Michał; Heymes, David; Mitov, Alexander

    2017-04-01

    We calculate all major differential distributions with stable top-quarks at the LHC. The calculation covers the multi-TeV range that will be explored during LHC Run II and beyond. Our results are in the form of high-quality binned distributions. We offer predictions based on three different parton distribution function (pdf) sets. In the near future we will make our results available also in the more flexible fastNLO format that allows fast re-computation with any other pdf set. In order to be able to extend our calculation into the multi-TeV range we have had to derive a set of dynamic scales. Such scales are selected based on the principle of fastest perturbative convergence applied to the differential and inclusive cross-section. Many observations from our study are likely to be applicable and useful to other precision processes at the LHC. With scale uncertainty now under good control, pdfs arise as the leading source of uncertainty for TeV top production. Based on our findings, true precision in the boosted regime will likely only be possible after new and improved pdf sets appear. We expect that LHC top-quark data will play an important role in this process.

  7. An efficient mass-preserving interface-correction level set/ghost fluid method for droplet suspensions under depletion forces

    NASA Astrophysics Data System (ADS)

    Ge, Zhouyang; Loiseau, Jean-Christophe; Tammisola, Outi; Brandt, Luca

    2018-01-01

    Aiming for the simulation of colloidal droplets in microfluidic devices, we present here a numerical method for two-fluid systems subject to surface tension and depletion forces among the suspended droplets. The algorithm is based on an efficient solver for the incompressible two-phase Navier-Stokes equations, and uses a mass-conserving level set method to capture the fluid interface. The four novel ingredients proposed here are, firstly, an interface-correction level set (ICLS) method; global mass conservation is achieved by performing an additional advection near the interface, with a correction velocity obtained by locally solving an algebraic equation, which is easy to implement in both 2D and 3D. Secondly, we report a second-order accurate geometric estimation of the curvature at the interface and, thirdly, the combination of the ghost fluid method with the fast pressure-correction approach enabling an accurate and fast computation even for large density contrasts. Finally, we derive a hydrodynamic model for the interaction forces induced by depletion of surfactant micelles and combine it with a multiple level set approach to study short-range interactions among droplets in the presence of attracting forces.

  8. Uncovering gender discrimination cues in a realistic setting.

    PubMed

    Dupuis-Roy, Nicolas; Fortin, Isabelle; Fiset, Daniel; Gosselin, Frédéric

    2009-02-10

    Which face cues do we use for gender discrimination? Few studies have tried to answer this question and the few that have tried typically used only a small set of grayscale stimuli, often distorted and presented a large number of times. Here, we reassessed the importance of facial cues for gender discrimination in a more realistic setting. We applied Bubbles-a technique that minimizes bias toward specific facial features and does not necessitate the distortion of stimuli-to a set of 300 color photographs of Caucasian faces, each presented only once to 30 participants. Results show that the region of the eyes and the eyebrows-probably in the light-dark channel-is the most important facial cue for accurate gender discrimination; and that the mouth region is driving fast correct responses (but not fast incorrect responses)-the gender discrimination information in the mouth region is concentrated in the red-green color channel. Together, these results suggest that, when color is informative in the mouth region, humans use it and respond rapidly; and, when it's not informative, they have to rely on the more robust but more sluggish luminance information in the eye-eyebrow region.

  9. Pravastatin reduces the risk for cardiovascular disease in Japanese hypercholesterolemic patients with impaired fasting glucose or diabetes: diabetes subanalysis of the Management of Elevated Cholesterol in the Primary Prevention Group of Adult Japanese (MEGA) Study.

    PubMed

    Tajima, Naoko; Kurata, Hideaki; Nakaya, Noriaki; Mizuno, Kyoichi; Ohashi, Yasuo; Kushiro, Toshio; Teramoto, Tamio; Uchiyama, Shinichiro; Nakamura, Haruo

    2008-08-01

    Diabetes mellitus (DM) is a major risk factor for cardiovascular disease (CVD) in patients with no history of CVD. Evidence for the effect of statins on CVD in the diabetic population in low-risk populations (e.g., Japanese) is limited. We evaluated the effect of pravastatin on risk reduction of CVD related to baseline glucose status in a primary prevention setting. The Management of Elevated Cholesterol in the Primary Prevention Group of Adult Japanese (MEGA) Study, in patients with mild-to-moderate hypercholesterolemia (220-270 mg/dL), showed that low-dose pravastatin significantly reduced the risk for CVD by 26%. This exploratory subanalyses examined the efficacy of diet plus pravastatin on CVD in 2210 patients with abnormal fasting glucose (AFG, including 1746 patients with DM and 464 patients with impaired fasting glucose (IFG) at 5 years in the MEGA Study. CVD was threefold higher in AFG patients (threefold higher in DM, and twofold higher in IFG) compared with normal fasting glucose (NFG) patients in the diet group. Diet plus pravastatin treatment significantly reduced the risk of CVD by 32% (hazard ratio 0.68, 95% CI 0.48-0.96, number needed to treat, 42) in the AFG group compared with the diet alone group, and no significant interaction between AFG and NFG (interaction P=0.85) was found. Safety problems were not observed during long-term treatment with pravastatin. In conclusion, pravastatin reduces the risk of CVD in subjects with hypercholesterolemia and abnormal fasting glucose in the primary prevention setting in Japan.

  10. Validation of a Multimarker Model for Assessing Risk of Type 2 Diabetes from a Five-Year Prospective Study of 6784 Danish People (Inter99)

    PubMed Central

    Urdea, Mickey; Kolberg, Janice; Wilber, Judith; Gerwien, Robert; Moler, Edward; Rowe, Michael; Jorgensen, Paul; Hansen, Torben; Pedersen, Oluf; Jørgensen, Torben; Borch-Johnsen, Knut

    2009-01-01

    Background Improved identification of subjects at high risk for development of type 2 diabetes would allow preventive interventions to be targeted toward individuals most likely to benefit. In previous research, predictive biomarkers were identified and used to develop multivariate models to assess an individual's risk of developing diabetes. Here we describe the training and validation of the PreDx™ Diabetes Risk Score (DRS) model in a clinical laboratory setting using baseline serum samples from subjects in the Inter99 cohort, a population-based primary prevention study of cardiovascular disease. Methods Among 6784 subjects free of diabetes at baseline, 215 subjects progressed to diabetes (converters) during five years of follow-up. A nested case-control study was performed using serum samples from 202 converters and 597 randomly selected nonconverters. Samples were randomly assigned to equally sized training and validation sets. Seven biomarkers were measured using assays developed for use in a clinical reference laboratory. Results The PreDx DRS model performed better on the training set (area under the curve [AUC] = 0.837) than fasting plasma glucose alone (AUC = 0.779). When applied to the sequestered validation set, the PreDx DRS showed the same performance (AUC = 0.838), thus validating the model. This model had a better AUC than any other single measure from a fasting sample. Moreover, the model provided further risk stratification among high-risk subpopulations with impaired fasting glucose or metabolic syndrome. Conclusions The PreDx DRS provides the absolute risk of diabetes conversion in five years for subjects identified to be “at risk” using the clinical factors. PMID:20144324

  11. Validation of a multimarker model for assessing risk of type 2 diabetes from a five-year prospective study of 6784 Danish people (Inter99).

    PubMed

    Urdea, Mickey; Kolberg, Janice; Wilber, Judith; Gerwien, Robert; Moler, Edward; Rowe, Michael; Jorgensen, Paul; Hansen, Torben; Pedersen, Oluf; Jørgensen, Torben; Borch-Johnsen, Knut

    2009-07-01

    Improved identification of subjects at high risk for development of type 2 diabetes would allow preventive interventions to be targeted toward individuals most likely to benefit. In previous research, predictive biomarkers were identified and used to develop multivariate models to assess an individual's risk of developing diabetes. Here we describe the training and validation of the PreDx Diabetes Risk Score (DRS) model in a clinical laboratory setting using baseline serum samples from subjects in the Inter99 cohort, a population-based primary prevention study of cardiovascular disease. Among 6784 subjects free of diabetes at baseline, 215 subjects progressed to diabetes (converters) during five years of follow-up. A nested case-control study was performed using serum samples from 202 converters and 597 randomly selected nonconverters. Samples were randomly assigned to equally sized training and validation sets. Seven biomarkers were measured using assays developed for use in a clinical reference laboratory. The PreDx DRS model performed better on the training set (area under the curve [AUC] = 0.837) than fasting plasma glucose alone (AUC = 0.779). When applied to the sequestered validation set, the PreDx DRS showed the same performance (AUC = 0.838), thus validating the model. This model had a better AUC than any other single measure from a fasting sample. Moreover, the model provided further risk stratification among high-risk subpopulations with impaired fasting glucose or metabolic syndrome. The PreDx DRS provides the absolute risk of diabetes conversion in five years for subjects identified to be "at risk" using the clinical factors. Copyright 2009 Diabetes Technology Society.

  12. Differential Regulation of Thyroid Hormone Metabolism Target Genes during Non-thyroidal Illness Syndrome Triggered by Fasting or Sepsis in Adult Mice

    PubMed Central

    Fontes, Klaus N.; Cabanelas, Adriana; Bloise, Flavia F.; de Andrade, Cherley Borba Vieira; Souza, Luana L.; Wilieman, Marianna; Trevenzoli, Isis H.; Agra, Lais C.; Silva, Johnatas D.; Bandeira-Melo, Christianne; Silva, Pedro L.; Rocco, Patricia R. M.; Ortiga-Carvalho, Tania M.

    2017-01-01

    Fasting and sepsis induce profound changes in thyroid hormone (TH) central and peripheral metabolism. These changes affect TH action and are called the non-thyroidal illness syndrome (NTIS). To date, it is still debated whether NTIS represents an adaptive response or a real hypothyroid state at the tissue level. Moreover, even though it has been considered the same syndrome, we hypothesized that fasting and sepsis induce a distinct set of changes in thyroid hormone metabolism. Herein, we aimed to evaluate the central and peripheral expression of genes involved in the transport (MCT8/Slc16a2 and MCT10/Slc16a10), metabolism (Dio1, Dio2, and Dio3) and action (Thra and Thrb) of TH during NTIS induced by fasting or sepsis. Male mice were subjected to a 48 h period of fasting or cecal ligation and puncture (CLP)-induced sepsis. At the peripheral level, fasting led to: (1) reduced serum thyroxine (T4) and triiodothyronine (T3), expression of Dio1, Thra, Slc16a2, and MCT8 protein in liver; (2) increased hepatic Slc16a10 and Dio3 expression; and (3) decreased Slc16a2 and Slc16a10 expressions in the thyroid gland. Fasting resulted in reduction of Tshb expression in the pituitary and increased expression of Dio2 in total hypothalamus, arcuate (ARC) and paraventricular (PVN) nucleus. CLP induced sepsis resulted in reduced: (1) T4 serum levels; (2) Dio1, Slc16a2, Slc16a10, Thra, and Thrb expression in liver as well as Slc16a2 expression in the thyroid gland (3) Thrb and Tshb mRNA expression in the pituitary; (4) total leukocyte counts in the bone marrow while increased its number in peritoneal and pleural fluids. In summary, fasting- or sepsis-driven NTIS promotes changes in the set point of hypothalamus-pituitary-thyroid axis through different mechanisms. Reduced hepatic THRs expression in conjunction with reduced TH transporters expression in the thyroid gland may indicate, respectively, reduction in the peripheral action and in the secretion of TH, which may contribute to the low TH serum levels observed in both models. PMID:29118715

  13. Differential Regulation of Thyroid Hormone Metabolism Target Genes during Non-thyoidal Illness Syndrome Triggered by Fasting or Sepsis in Adult Mice.

    PubMed

    Fontes, Klaus N; Cabanelas, Adriana; Bloise, Flavia F; de Andrade, Cherley Borba Vieira; Souza, Luana L; Wilieman, Marianna; Trevenzoli, Isis H; Agra, Lais C; Silva, Johnatas D; Bandeira-Melo, Christianne; Silva, Pedro L; Rocco, Patricia R M; Ortiga-Carvalho, Tania M

    2017-01-01

    Fasting and sepsis induce profound changes in thyroid hormone (TH) central and peripheral metabolism. These changes affect TH action and are called the non-thyroidal illness syndrome (NTIS). To date, it is still debated whether NTIS represents an adaptive response or a real hypothyroid state at the tissue level. Moreover, even though it has been considered the same syndrome, we hypothesized that fasting and sepsis induce a distinct set of changes in thyroid hormone metabolism. Herein, we aimed to evaluate the central and peripheral expression of genes involved in the transport (MCT8/ Slc16a2 and MCT10/ Slc16a10 ), metabolism ( Dio1, Dio2 , and Dio3 ) and action ( Thra and Thrb ) of TH during NTIS induced by fasting or sepsis. Male mice were subjected to a 48 h period of fasting or cecal ligation and puncture (CLP)-induced sepsis. At the peripheral level, fasting led to: (1) reduced serum thyroxine (T 4 ) and triiodothyronine (T 3 ), expression of Dio1, Thra, Slc16a2 , and MCT8 protein in liver; (2) increased hepatic Slc16a10 and Dio3 expression; and (3) decreased Slc16a2 and Slc16a10 expressions in the thyroid gland. Fasting resulted in reduction of Tshb expression in the pituitary and increased expression of Dio2 in total hypothalamus, arcuate (ARC) and paraventricular (PVN) nucleus. CLP induced sepsis resulted in reduced: (1) T 4 serum levels; (2) Dio1, Slc16a2, Slc16a10, Thra , and Thrb expression in liver as well as Slc16a2 expression in the thyroid gland (3) Thrb and Tshb mRNA expression in the pituitary; (4) total leukocyte counts in the bone marrow while increased its number in peritoneal and pleural fluids. In summary, fasting- or sepsis-driven NTIS promotes changes in the set point of hypothalamus-pituitary-thyroid axis through different mechanisms. Reduced hepatic THRs expression in conjunction with reduced TH transporters expression in the thyroid gland may indicate, respectively, reduction in the peripheral action and in the secretion of TH, which may contribute to the low TH serum levels observed in both models.

  14. Risk of misclassification with a non-fasting lipid profile in secondary cardiovascular prevention.

    PubMed

    Klop, Boudewijn; Hartong, Simone C C; Vermeer, Henricus J; Schoofs, Mariette W C J; Kofflard, Marcel J M

    2017-09-01

    Routinely fasting is not necessary for measuring the lipid profile according to the latest European consensus. However, LDL-C tends to be lower in the non-fasting state with risk of misclassification. The extent of misclassification in secondary cardiovascular prevention with a non-fasting lipid profile was investigated. 329 patients on lipid lowering therapy for secondary cardiovascular prevention measured a fasting and non-fasting lipid profile. Cut-off values for LDL-C, non-HDL-C and apolipoprotein B were set at <1.8mmol/l, <2.6mmol/l and <0.8g/l, respectively. Study outcomes were net misclassification with non-fasting LDL-C (calculated using the Friedewald formula), direct LDL-C, non-HDL-C and apolipoprotein B. Net misclassification <10% was considered clinically irrelevant. Mean age was 68.3±8.5years and the majority were men (79%). Non-fasting measurements resulted in lower LDL-C (-0.2±0.4mmol/l, P<0.001), direct LDL-C (-0.1±0.2mmol/l, P=0.001), non-HDL-C (-0.1±0.4mmol/l, P=0.004) and apolipoprotein B (-0.02±0.10g/l, P=0.004). 36.0% of the patients reached a fasting LDL-C target of <1.8mmol/l with a significant net misclassification of 10.7% (95% CI 6.4-15.0%) in the non-fasting state. In the non-fasting state net misclassification with direct LDL-C was 5.7% (95% CI 2.1-9.2%), 4.0% (95% CI 1.0-7.4%) with non-HDL-C and 4.1% (95% CI 1.1-9.1%) with apolipoprotein B. Use of non-fasting LDL-C as treatment target in secondary cardiovascular prevention resulted in significant misclassification with subsequent risk of undertreatment, whereas non-fasting direct LDL-C, non-HDL-C and apolipoprotein B are reliable parameters. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Fast and Adaptive Sparse Precision Matrix Estimation in High Dimensions

    PubMed Central

    Liu, Weidong; Luo, Xi

    2014-01-01

    This paper proposes a new method for estimating sparse precision matrices in the high dimensional setting. It has been popular to study fast computation and adaptive procedures for this problem. We propose a novel approach, called Sparse Column-wise Inverse Operator, to address these two issues. We analyze an adaptive procedure based on cross validation, and establish its convergence rate under the Frobenius norm. The convergence rates under other matrix norms are also established. This method also enjoys the advantage of fast computation for large-scale problems, via a coordinate descent algorithm. Numerical merits are illustrated using both simulated and real datasets. In particular, it performs favorably on an HIV brain tissue dataset and an ADHD resting-state fMRI dataset. PMID:25750463

  16. Phonological mismatch makes aided speech recognition in noise cognitively taxing.

    PubMed

    Rudner, Mary; Foo, Catharina; Rönnberg, Jerker; Lunner, Thomas

    2007-12-01

    The working memory framework for Ease of Language Understanding predicts that speech processing becomes more effortful, thus requiring more explicit cognitive resources, when there is mismatch between speech input and phonological representations in long-term memory. To test this prediction, we changed the compression release settings in the hearing instruments of experienced users and allowed them to train for 9 weeks with the new settings. After training, aided speech recognition in noise was tested with both the trained settings and orthogonal settings. We postulated that training would lead to acclimatization to the trained setting, which in turn would involve establishment of new phonological representations in long-term memory. Further, we postulated that after training, testing with orthogonal settings would give rise to phonological mismatch, associated with more explicit cognitive processing. Thirty-two participants (mean=70.3 years, SD=7.7) with bilateral sensorineural hearing loss (pure-tone average=46.0 dB HL, SD=6.5), bilaterally fitted for more than 1 year with digital, two-channel, nonlinear signal processing hearing instruments and chosen from the patient population at the Linköping University Hospital were randomly assigned to 9 weeks training with new, fast (40 ms) or slow (640 ms), compression release settings in both channels. Aided speech recognition in noise performance was tested according to a design with three within-group factors: test occasion (T1, T2), test setting (fast, slow), and type of noise (unmodulated, modulated) and one between-group factor: experience setting (fast, slow) for two types of speech materials-the highly constrained Hagerman sentences and the less-predictable Hearing in Noise Test (HINT). Complex cognitive capacity was measured using the reading span and letter monitoring tests. PREDICTION: We predicted that speech recognition in noise at T2 with mismatched experience and test settings would be associated with more explicit cognitive processing and thus stronger correlations with complex cognitive measures, as well as poorer performance if complex cognitive capacity was exceeded. Under mismatch conditions, stronger correlations were found between performance on speech recognition with the Hagerman sentences and reading span, along with poorer speech recognition for participants with low reading span scores. No consistent mismatch effect was found with HINT. The mismatch prediction generated by the working memory framework for Ease of Language Understanding is supported for speech recognition in noise with the highly constrained Hagerman sentences but not the less-predictable HINT.

  17. A Validation and Code-to-Code Verification of FAST for a Megawatt-Scale Wind Turbine with Aeroelastically Tailored Blades

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guntur, Srinivas; Jonkman, Jason; Sievers, Ryan

    This paper presents validation and code-to-code verification of the latest version of the U.S. Department of Energy, National Renewable Energy Laboratory wind turbine aeroelastic engineering simulation tool, FAST v8. A set of 1,141 test cases, for which experimental data from a Siemens 2.3 MW machine have been made available and were in accordance with the International Electrotechnical Commission 61400-13 guidelines, were identified. These conditions were simulated using FAST as well as the Siemens in-house aeroelastic code, BHawC. This paper presents a detailed analysis comparing results from FAST with those from BHawC as well as experimental measurements, using statistics including themore » means and the standard deviations along with the power spectral densities of select turbine parameters and loads. Results indicate a good agreement among the predictions using FAST, BHawC, and experimental measurements. Here, these agreements are discussed in detail in this paper, along with some comments regarding the differences seen in these comparisons relative to the inherent uncertainties in such a model-based analysis.« less

  18. A Validation and Code-to-Code Verification of FAST for a Megawatt-Scale Wind Turbine with Aeroelastically Tailored Blades

    DOE PAGES

    Guntur, Srinivas; Jonkman, Jason; Sievers, Ryan; ...

    2017-08-29

    This paper presents validation and code-to-code verification of the latest version of the U.S. Department of Energy, National Renewable Energy Laboratory wind turbine aeroelastic engineering simulation tool, FAST v8. A set of 1,141 test cases, for which experimental data from a Siemens 2.3 MW machine have been made available and were in accordance with the International Electrotechnical Commission 61400-13 guidelines, were identified. These conditions were simulated using FAST as well as the Siemens in-house aeroelastic code, BHawC. This paper presents a detailed analysis comparing results from FAST with those from BHawC as well as experimental measurements, using statistics including themore » means and the standard deviations along with the power spectral densities of select turbine parameters and loads. Results indicate a good agreement among the predictions using FAST, BHawC, and experimental measurements. Here, these agreements are discussed in detail in this paper, along with some comments regarding the differences seen in these comparisons relative to the inherent uncertainties in such a model-based analysis.« less

  19. A fast mass spring model solver for high-resolution elastic objects

    NASA Astrophysics Data System (ADS)

    Zheng, Mianlun; Yuan, Zhiyong; Zhu, Weixu; Zhang, Guian

    2017-03-01

    Real-time simulation of elastic objects is of great importance for computer graphics and virtual reality applications. The fast mass spring model solver can achieve visually realistic simulation in an efficient way. Unfortunately, this method suffers from resolution limitations and lack of mechanical realism for a surface geometry model, which greatly restricts its application. To tackle these problems, in this paper we propose a fast mass spring model solver for high-resolution elastic objects. First, we project the complex surface geometry model into a set of uniform grid cells as cages through *cages mean value coordinate method to reflect its internal structure and mechanics properties. Then, we replace the original Cholesky decomposition method in the fast mass spring model solver with a conjugate gradient method, which can make the fast mass spring model solver more efficient for detailed surface geometry models. Finally, we propose a graphics processing unit accelerated parallel algorithm for the conjugate gradient method. Experimental results show that our method can realize efficient deformation simulation of 3D elastic objects with visual reality and physical fidelity, which has a great potential for applications in computer animation.

  20. On the nature of fast sausage waves in coronal loops

    NASA Astrophysics Data System (ADS)

    Bahari, Karam

    2018-05-01

    The effect of the parameters of coronal loops on the nature of fast sausage waves are investigated. To do this three models of the coronal loop considered, a simple loop model, a current-carrying loop model and a model with radially structured density called "Inner μ" profile. For all the models the Magnetohydrodynamic (MHD) equations solved analytically in the linear approximation and the restoring forces of oscillations obtained. The ratio of the magnetic tension force to the pressure gradient force obtained as a function of the distance from the axis of the loop. In the simple loop model for all values of the loop parameters the fast sausages wave have a mixed nature of Alfvénic and fast MHD waves, in the current-carrying loop model with thick annulus and low density contrast the fast sausage waves can be considered as purely Alfvénic wave in the core region of the loop, and in the "Inner μ" profile for each set of the parameters of the loop the wave can be considered as a purely Alfvénic wave in some regions of the loop.

  1. Benchmarking study of the MCNP code against cold critical experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sitaraman, S.

    1991-01-01

    The purpose of this study was to benchmark the widely used Monte Carlo code MCNP against a set of cold critical experiments with a view to using the code as a means of independently verifying the performance of faster but less accurate Monte Carlo and deterministic codes. The experiments simulated consisted of both fast and thermal criticals as well as fuel in a variety of chemical forms. A standard set of benchmark cold critical experiments was modeled. These included the two fast experiments, GODIVA and JEZEBEL, the TRX metallic uranium thermal experiments, the Babcock and Wilcox oxide and mixed oxidemore » experiments, and the Oak Ridge National Laboratory (ORNL) and Pacific Northwest Laboratory (PNL) nitrate solution experiments. The principal case studied was a small critical experiment that was performed with boiling water reactor bundles.« less

  2. Fast Steerable Principal Component Analysis

    PubMed Central

    Zhao, Zhizhen; Shkolnisky, Yoel; Singer, Amit

    2016-01-01

    Cryo-electron microscopy nowadays often requires the analysis of hundreds of thousands of 2-D images as large as a few hundred pixels in each direction. Here, we introduce an algorithm that efficiently and accurately performs principal component analysis (PCA) for a large set of 2-D images, and, for each image, the set of its uniform rotations in the plane and their reflections. For a dataset consisting of n images of size L × L pixels, the computational complexity of our algorithm is O(nL3 + L4), while existing algorithms take O(nL4). The new algorithm computes the expansion coefficients of the images in a Fourier–Bessel basis efficiently using the nonuniform fast Fourier transform. We compare the accuracy and efficiency of the new algorithm with traditional PCA and existing algorithms for steerable PCA. PMID:27570801

  3. Accelerating the Convergence of Replica Exchange Simulations Using Gibbs Sampling and Adaptive Temperature Sets

    DOE PAGES

    Vogel, Thomas; Perez, Danny

    2015-08-28

    We recently introduced a novel replica-exchange scheme in which an individual replica can sample from states encountered by other replicas at any previous time by way of a global configuration database, enabling the fast propagation of relevant states through the whole ensemble of replicas. This mechanism depends on the knowledge of global thermodynamic functions which are measured during the simulation and not coupled to the heat bath temperatures driving the individual simulations. Therefore, this setup also allows for a continuous adaptation of the temperature set. In this paper, we will review the new scheme and demonstrate its capability. Furthermore, themore » method is particularly useful for the fast and reliable estimation of the microcanonical temperature T(U) or, equivalently, of the density of states g(U) over a wide range of energies.« less

  4. Segmentation of hand radiographs using fast marching methods

    NASA Astrophysics Data System (ADS)

    Chen, Hong; Novak, Carol L.

    2006-03-01

    Rheumatoid Arthritis is one of the most common chronic diseases. Joint space width in hand radiographs is evaluated to assess joint damage in order to monitor progression of disease and response to treatment. Manual measurement of joint space width is time-consuming and highly prone to inter- and intra-observer variation. We propose a method for automatic extraction of finger bone boundaries using fast marching methods for quantitative evaluation of joint space width. The proposed algorithm includes two stages: location of hand joints followed by extraction of bone boundaries. By setting the propagation speed of the wave front as a function of image intensity values, the fast marching algorithm extracts the skeleton of the hands, in which each branch corresponds to a finger. The finger joint locations are then determined by using the image gradients along the skeletal branches. In order to extract bone boundaries at joints, the gradient magnitudes are utilized for setting the propagation speed, and the gradient phases are used for discriminating the boundaries of adjacent bones. The bone boundaries are detected by searching for the fastest paths from one side of each joint to the other side. Finally, joint space width is computed based on the extracted upper and lower bone boundaries. The algorithm was evaluated on a test set of 8 two-hand radiographs, including images from healthy patients and from patients suffering from arthritis, gout and psoriasis. Using our method, 97% of 208 joints were accurately located and 89% of 416 bone boundaries were correctly extracted.

  5. Effects of ATC automation on precision approaches to closely space parallel runways

    NASA Technical Reports Server (NTRS)

    Slattery, R.; Lee, K.; Sanford, B.

    1995-01-01

    Improved navigational technology (such as the Microwave Landing System and the Global Positioning System) installed in modern aircraft will enable air traffic controllers to better utilize available airspace. Consequently, arrival traffic can fly approaches to parallel runways separated by smaller distances than are currently allowed. Previous simulation studies of advanced navigation approaches have found that controller workload is increased when there is a combination of aircraft that are capable of following advanced navigation routes and aircraft that are not. Research into Air Traffic Control automation at Ames Research Center has led to the development of the Center-TRACON Automation System (CTAS). The Final Approach Spacing Tool (FAST) is the component of the CTAS used in the TRACON area. The work in this paper examines, via simulation, the effects of FAST used for aircraft landing on closely spaced parallel runways. The simulation contained various combinations of aircraft, equipped and unequipped with advanced navigation systems. A set of simulations was run both manually and with an augmented set of FAST advisories to sequence aircraft, assign runways, and avoid conflicts. The results of the simulations are analyzed, measuring the airport throughput, aircraft delay, loss of separation, and controller workload.

  6. Strategically Leapfrogging Education in Prehospital Trauma Management: Four-Tiered Training Protocols

    PubMed Central

    Abraham, Rohit; Vyas, Dinesh; Narayan, Mayur; Vyas, Arpita

    2016-01-01

    Trauma-related injury in fast developing countries are linked to 90% of international mortality rates, which can be greatly reduced by improvements in often non-existent or non-centralized emergency medical systems (EMS)—particularly in the pre-hospital care phase. Traditional trauma training protocols—such as Advanced Trauma Life Support (ATLS), International Trauma Life Support (ITLS), and Basic Life Support (BLS)—have failed to produce an effective pre-hospital ground force of medical first responders. To overcome these barriers, we propose a new four-tiered set of trauma training protocols: Massive Open Online Course (MOOC) Trauma Training, Acute Trauma Training (ATT), Broad Trauma Training (BTT), and Cardiac and Trauma Training (CTT). These standards are specifically differentiated to accommodate the educational and socioeconomic diversity found in fast developing settings, where each free course is taught in native, lay language while ensuring the education standards are maintained by fully incorporating high-fidelity simulation, video-recorded debriefing, and retraining. The innovative pedagogy of this trauma education program utilizes MOOC for global scalability and a “train-the-trainer” approach for exponential growth—both components help fast developing countries reach a critical mass of first responders needed for the base of an evolving EMS. PMID:27419222

  7. Strategically Leapfrogging Education in Prehospital Trauma Management: Four-Tiered Training Protocols.

    PubMed

    Abraham, Rohit; Vyas, Dinesh; Narayan, Mayur; Vyas, Arpita

    2015-12-01

    Trauma-related injury in fast developing countries are linked to 90% of international mortality rates, which can be greatly reduced by improvements in often non-existent or non-centralized emergency medical systems (EMS)-particularly in the pre-hospital care phase. Traditional trauma training protocols-such as Advanced Trauma Life Support (ATLS), International Trauma Life Support (ITLS), and Basic Life Support (BLS)-have failed to produce an effective pre-hospital ground force of medical first responders. To overcome these barriers, we propose a new four-tiered set of trauma training protocols: Massive Open Online Course (MOOC) Trauma Training, Acute Trauma Training (ATT), Broad Trauma Training (BTT), and Cardiac and Trauma Training (CTT). These standards are specifically differentiated to accommodate the educational and socioeconomic diversity found in fast developing settings, where each free course is taught in native, lay language while ensuring the education standards are maintained by fully incorporating high-fidelity simulation, video-recorded debriefing, and retraining. The innovative pedagogy of this trauma education program utilizes MOOC for global scalability and a "train-the-trainer" approach for exponential growth-both components help fast developing countries reach a critical mass of first responders needed for the base of an evolving EMS.

  8. Model of head-neck joint fast movements in the frontal plane.

    PubMed

    Pedrocchi, A; Ferrigno, G

    2004-06-01

    The objective of this work is to develop a model representing the physiological systems driving fast head movements in frontal plane. All the contributions occurring mechanically in the head movement are considered: damping, stiffness, physiological limit of range of motion, gravitational field, and muscular torques due to voluntary activation as well as to stretch reflex depending on fusal afferences. Model parameters are partly derived from the literature, when possible, whereas undetermined block parameters are determined by optimising the model output, fitting to real kinematics data acquired by a motion capture system in specific experimental set-ups. The optimisation for parameter identification is performed by genetic algorithms. Results show that the model represents very well fast head movements in the whole range of inclination in the frontal plane. Such a model could be proposed as a tool for transforming kinematics data on head movements in 'neural equivalent data', especially for assessing head control disease and properly planning the rehabilitation process. In addition, the use of genetic algorithms seems to fit well the problem of parameter identification, allowing for the use of a very simple experimental set-up and granting model robustness.

  9. VUV absorption spectroscopy measurements of the role of fast neutral atoms in high-power gap breakdown

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    FILUK,A.B.; BAILEY,JAMES E.; CUNEO,MICHAEL E.

    The maximum power achieved in a wide variety of high-power devices, including electron and ion diodes, z pinches, and microwave generators, is presently limited by anode-cathode gap breakdown. A frequently-discussed hypothesis for this effect is ionization of fast neutral atoms injected throughout the anode-cathode gap during the power pulse. The authors describe a newly-developed diagnostic tool that provides the first direct test of this hypothesis. Time-resolved vacuum-ultraviolet absorption spectroscopy is used to directly probe fast neutral atoms with 1 mm spatial resolution in the 10 mm anode-cathode gap of the SABRE 5 MV, 1 TW applied-B ion diode. Absorption spectramore » collected during Ar RF glow discharges and with CO{sub 2} gas fills confirm the reliability of the diagnostic technique. Throughout the 50--100 ns ion diode pulses no measurable neutral absorption is seen, setting upper limits of 0.12--1.5 x 10{sup 14} cm{sup {minus}3} for ground state fast neutral atom densities of H, C, N, O, F. The absence of molecular absorption bands also sets upper limits of 0.16--1.2 x 10{sup 15} cm{sup {minus}3} for common simple molecules. These limits are low enough to rule out ionization throughout the gap as a breakdown mechanism. This technique can now be applied to quantify the role of neutral atoms in other high-power devices.« less

  10. Is fasting safe? A chart review of adverse events during medically supervised, water-only fasting.

    PubMed

    Finnell, John S; Saul, Bradley C; Goldhamer, Alan C; Myers, Toshia R

    2018-02-20

    Evidence suggests that fasting, during which only water is consumed, results in potentially health promoting physiological effects. However, peer-reviewed research assessing the safety of water-only fasting is lacking. To address this, we conducted a chart review to describe adverse events (AEs) that occurred during medically supervised, water-only fasting. Electronic charts from patient visits to a residential medical facility from 2006 to 2011 were reviewed. Patients who were at least 21 years of age and water-only fasted for ≥2 consecutive days with a refeeding period equal to half of the fast length were included. Out of 2539 charts, 768 visits met our inclusion and exclusion criteria. AEs were abstracted from chart notes and classified according to CTCAE (v4.03) and MedDRA (v12.1) terminology. Descriptive analysis of AEs is reported. During the protocol period, the highest grade AE (HGAE) in 555 visits was a grade 2 event or lower, in 212 visits it was a grade 3 event, in 1 visit it was a grade 4 event, and there were no grade 5 events. There were 2 (0.002%) visits with a serious adverse event (SAE). The majority of AEs identified were mild (n = 4490, 75%) in nature and known reactions to fasting. To our knowledge, this is the most comprehensive analysis of AEs experienced during medically supervised, water-only fasting conducted to date. Overall, our data indicate that the majority of AEs experienced were mild to moderate and known reactions to fasting. This suggests that the protocol used in this study can be safely implemented in a medical setting with minimal risk of a SAE.

  11. Characterization of the fast electrons distribution produced in a high intensity laser target interaction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Westover, B.; Lawrence Livermore National Laboratory, Livermore, California 94550; Chen, C. D.

    2014-03-15

    Experiments on the Titan laser (∼150 J, 0.7 ps, 2 × 10{sup 20} W cm{sup −2}) at the Lawrence Livermore National Laboratory were carried out in order to study the properties of fast electrons produced by high-intensity, short pulse laser interacting with matter under conditions relevant to Fast Ignition. Bremsstrahlung x-rays produced by these fast electrons were measured by a set of compact filter-stack based x-ray detectors placed at three angles with respect to the target. The measured bremsstrahlung signal allows a characterization of the fast electron beam spectrum, conversion efficiency of laser energy into fast electron kinetic energy and angular distribution. A Monte Carlo codemore » Integrated Tiger Series was used to model the bremsstrahlung signal and infer a laser to fast electron conversion efficiency of 30%, an electron slope temperature of about 2.2 MeV, and a mean divergence angle of 39°. Simulations were also performed with the hybrid transport code ZUMA which includes fields in the target. In this case, a conversion efficiency of laser energy to fast electron energy of 34% and a slope temperature between 1.5 MeV and 4 MeV depending on the angle between the target normal direction and the measuring spectrometer are found. The observed temperature of the bremsstrahlung spectrum, and therefore the inferred electron spectrum are found to be angle dependent.« less

  12. Using Facebook and Other SNSs in K-12 Classrooms: Ethical Considerations for Safe Social Networking

    ERIC Educational Resources Information Center

    Howard, Keith

    2013-01-01

    The purpose of this article is to examine the potential risks of bringing social networking sites (SNS) into the classroom through the lens of Moor's (1999) just-consequentialist theory. Moor compares the setting of ethical policies in the fast-changing world of technology to a sailor trying to set a course while sailing. His analogy could not be…

  13. COED Transactions, Vol. X, No. 9, September 1978. Use of the Analog/Hybrid Computer in Boundary Layer and Convection Studies.

    ERIC Educational Resources Information Center

    Mitchell, Eugene E., Ed.

    In certain boundary layer or natural convection work, where a similarity transformation is valid, the equations can be reduced to a set of nonlinear ordinary differential equations. They are therefore well-suited to a fast solution on an analog/hybrid computer. This paper illustrates such usage of the analog/hybrid computer by a set of…

  14. Providing Calorie Information on Fast-Food Restaurant Menu Boards: Consumer Views

    PubMed Central

    Fitch, Rebecca C.; Harnack, Lisa J.; Neumark-Sztainer, Dianne R.; Story, Mary T.; French, Simone A.; Oakes, J. Michael; Rydell, Sarah A.

    2010-01-01

    Purpose To gather consumer input about approaches to providing energy composition information for foods on fast-food restaurant menus. Design We asked a subset of individuals (n = 150) in an experimental study about the influence of nutrition labeling on fast-food meal choices to evaluate calorie information on mock fast-food menus in various formats. Setting Three community sites in the Minneapolis-St. Paul, Minnesota, metropolitan area. Subjects Adolescents and adults who ate fast food at least once per week were recruited. Measures Via a series of open- and close-ended questions, participants gave feedback about several formats for providing energy composition information for foods on fast-food restaurant menus. Analysis Means and frequencies were calculated, and χ2 tests were conducted. Results When asked to compare a menu that provided calorie information for each menu item with a menu that provided the number of minutes of running that would be required to burn the calories contained in each menu item, 71.0% of participants preferred the calorie information over the physical activity information. Participants also compared two approaches to providing caloric reference information on the menu (average daily calorie needs per day vs. per meal), and 61.3% preferred the calorie needs–per-meal format. Conclusion Our results may be useful in designing approaches to providing energy composition information for foods on fast-food restaurant menus. PMID:19928485

  15. Comparison of fasting and non-fasting lipid profiles in a large cohort of patients presenting at a community hospital.

    PubMed

    Cartier, Louis-Jacques; Collins, Charlene; Lagacé, Mathieu; Douville, Pierre

    2018-02-01

    To compare the fasting and non-fasting lipid profile including ApoB in a cohort of patients from a community setting. Our purpose was to determine the proportion of results that could be explained by the known biological variation in the fasting state and to examine the additional impact of non-fasting on these same lipid parameters. 1093 adult outpatients with fasting lipid requests were recruited from February to September 2016 at the blood collection sites of the Moncton Hospital. Participants were asked to come back in the next 3-4days after having eaten a regular breakfast to have their blood drawn for a non-fasting lipid profile. 91.6% of patients in this study had a change in total cholesterol that fell within the biological variation expected for this parameter. Similar results were seen for HDL-C (94.3%) non-HDL-C (88.8%) and ApoB (93.0%). A smaller number of patients fell within the biological variation expected for TG (78.8%) and LDL-C (74.6%). An average TG increase of 0.3mmol/L was observed in fed patients no matter the level of fasting TG. A gradual widening in the range of change in TG concentration was observed as fasting TG increased. Similar results were seen in diabetic patients. Outside of LDL-C and TG, little changes were seen in lipid parameters in the postprandial state. A large part of these changes could be explained by the biological variation. We observed a gradual widening in the range of increase in TG for patients with higher fasting TG. Non-HDL-C and ApoB should be the treatment target of choice for patients in the non-fasting state. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  16. Progression from impaired fasting glucose to type 2 diabetes mellitus among Chinese subjects with and without hypertension in a primary care setting.

    PubMed

    Fu, Sau Nga; Luk, Wan; Wong, Carlos King Ho; Cheung, Kwok Leung

    2014-09-01

    The progression from impaired fasting glucose (IFG) to type 2 diabetes mellitus (T2DM) in Chinese subjects, with and without hypertension, in a primary care setting was unknown. The present retrospective multicenter 5-year (2002-2007) cohort study was performed on IFG subjects attending 23 general outpatient clinics who were identified by their elevated fasting blood glucose laboratory results. Development of T2DM was determined by physician diagnosis of T2DM or starting of oral antidiabetic drugs within 5 years. The relationship between the time of T2DM diagnosis and subject characteristics was assessed by adjusted hazard ratios (aHR) from Cox hazards model. Of the 9161 IFG subjects, 4080 (45%) were men and 5081 (55%) were women. There were 1998 subjects who developed T2DM. The 5-year cumulative incidence was 0.218, whereas the overall annual incidence rate was 5.981/100 person-years. Subjects were more likely to develop T2DM if they were hypertensive (aHR = 1.44; 95% confidence interval [CI] 1.28-1.62; P < 0.001), aged <60 years (aHR = 1.36, 95% CI 1.24-1.49; P < 0.001), female (aHR = 1.18, 95% CI 1.08-1.29; P < 0.001), and had higher fasting glucose levels (6.39 ± 0.49 vs 6.24 ± 0.43 mmol/L in the group that developed T2DM vs the group without T2DM, respectively; aHR = 2.01, 95% CI 1.83-2.20; P < 0.001). Overall, more than one-fifth of IFG subjects in the primary care setting developed T2DM within 5 years. Health care professionals can target interventions to patients with risk factors for disease progression. © 2014 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and Wiley Publishing Asia Pty Ltd.

  17. Nonlinear effects associated with fast magnetosonic waves and turbulent magnetic amplification in laboratory and astrophysical plasmas

    NASA Astrophysics Data System (ADS)

    Tiwary, PremPyari; Sharma, Swati; Sharma, Prachi; Singh, Ram Kishor; Uma, R.; Sharma, R. P.

    2016-12-01

    This paper presents the spatio-temporal evolution of magnetic field due to the nonlinear coupling between fast magnetosonic wave (FMSW) and low frequency slow Alfvén wave (SAW). The dynamical equations of finite frequency FMSW and SAW in the presence of ponderomotive force of FMSW (pump wave) has been presented. Numerical simulation has been carried out for the nonlinear coupled equations of finite frequency FMSW and SAW. A systematic scan of the nonlinear behavior/evolution of the pump FMSW has been done for one of the set of parameters chosen in this paper, using the coupled dynamical equations. Filamentation of fast magnetosonic wave has been considered to be responsible for the magnetic turbulence during the laser plasma interaction. The results show that the formation and growth of localized structures depend on the background magnetic field but the order of amplification does not get affected by the magnitude of the background magnetic field. In this paper, we have shown the relevance of our model for two different parameters used in laboratory and astrophysical phenomenon. We have used one set of parameters pertaining to experimental observations in the study of fast ignition of laser fusion and hence studied the turbulent structures in stellar environment. The other set corresponds to the study of magnetic field amplification in the clumpy medium surrounding the supernova remnant Cassiopeia A. The results indicate considerable randomness in the spatial structure of the magnetic field profile in both the cases and gives a sufficient indication of turbulence. The turbulent spectra have been studied and the break point has been found around k which is consistent with the observations in both the cases. The nonlinear wave-wave interaction presented in this paper may be important in understanding the turbulence in the laboratory as well as the astrophysical phenomenon.

  18. Product evaluation : Thoro product demonstration

    DOT National Transportation Integrated Search

    1986-07-18

    This report contains a product evaluation of Thoro System's "Roadpatch" and "Thorite". Roadpatch is a cement base, fast-setting patching material. The material is fortified with special alkali resistant glass fibers. It is designed to repair potholes...

  19. Fast and Accurate Prediction of Stratified Steel Temperature During Holding Period of Ladle

    NASA Astrophysics Data System (ADS)

    Deodhar, Anirudh; Singh, Umesh; Shukla, Rishabh; Gautham, B. P.; Singh, Amarendra K.

    2017-04-01

    Thermal stratification of liquid steel in a ladle during the holding period and the teeming operation has a direct bearing on the superheat available at the caster and hence on the caster set points such as casting speed and cooling rates. The changes in the caster set points are typically carried out based on temperature measurements at the end of tundish outlet. Thermal prediction models provide advance knowledge of the influence of process and design parameters on the steel temperature at various stages. Therefore, they can be used in making accurate decisions about the caster set points in real time. However, this requires both fast and accurate thermal prediction models. In this work, we develop a surrogate model for the prediction of thermal stratification using data extracted from a set of computational fluid dynamics (CFD) simulations, pre-determined using design of experiments technique. Regression method is used for training the predictor. The model predicts the stratified temperature profile instantaneously, for a given set of process parameters such as initial steel temperature, refractory heat content, slag thickness, and holding time. More than 96 pct of the predicted values are within an error range of ±5 K (±5 °C), when compared against corresponding CFD results. Considering its accuracy and computational efficiency, the model can be extended for thermal control of casting operations. This work also sets a benchmark for developing similar thermal models for downstream processes such as tundish and caster.

  20. Integration of SimSET photon history generator in GATE for efficient Monte Carlo simulations of pinhole SPECT.

    PubMed

    Chen, Chia-Lin; Wang, Yuchuan; Lee, Jason J S; Tsui, Benjamin M W

    2008-07-01

    The authors developed and validated an efficient Monte Carlo simulation (MCS) workflow to facilitate small animal pinhole SPECT imaging research. This workflow seamlessly integrates two existing MCS tools: simulation system for emission tomography (SimSET) and GEANT4 application for emission tomography (GATE). Specifically, we retained the strength of GATE in describing complex collimator/detector configurations to meet the anticipated needs for studying advanced pinhole collimation (e.g., multipinhole) geometry, while inserting the fast SimSET photon history generator (PHG) to circumvent the relatively slow GEANT4 MCS code used by GATE in simulating photon interactions inside voxelized phantoms. For validation, data generated from this new SimSET-GATE workflow were compared with those from GATE-only simulations as well as experimental measurements obtained using a commercial small animal pinhole SPECT system. Our results showed excellent agreement (e.g., in system point response functions and energy spectra) between SimSET-GATE and GATE-only simulations, and, more importantly, a significant computational speedup (up to approximately 10-fold) provided by the new workflow. Satisfactory agreement between MCS results and experimental data were also observed. In conclusion, the authors have successfully integrated SimSET photon history generator in GATE for fast and realistic pinhole SPECT simulations, which can facilitate research in, for example, the development and application of quantitative pinhole and multipinhole SPECT for small animal imaging. This integrated simulation tool can also be adapted for studying other preclinical and clinical SPECT techniques.

  1. LBM-EP: Lattice-Boltzmann method for fast cardiac electrophysiology simulation from 3D images.

    PubMed

    Rapaka, S; Mansi, T; Georgescu, B; Pop, M; Wright, G A; Kamen, A; Comaniciu, Dorin

    2012-01-01

    Current treatments of heart rhythm troubles require careful planning and guidance for optimal outcomes. Computational models of cardiac electrophysiology are being proposed for therapy planning but current approaches are either too simplified or too computationally intensive for patient-specific simulations in clinical practice. This paper presents a novel approach, LBM-EP, to solve any type of mono-domain cardiac electrophysiology models at near real-time that is especially tailored for patient-specific simulations. The domain is discretized on a Cartesian grid with a level-set representation of patient's heart geometry, previously estimated from images automatically. The cell model is calculated node-wise, while the transmembrane potential is diffused using Lattice-Boltzmann method within the domain defined by the level-set. Experiments on synthetic cases, on a data set from CESC'10 and on one patient with myocardium scar showed that LBM-EP provides results comparable to an FEM implementation, while being 10 - 45 times faster. Fast, accurate, scalable and requiring no specific meshing, LBM-EP paves the way to efficient and detailed models of cardiac electrophysiology for therapy planning.

  2. Increasing Student Understanding of Microscope Optics by Building and Testing the Limits of Simple, Hand-Made Model Microscopes†

    PubMed Central

    Drace, Kevin; Couch, Brett; Keeling, Patrick J.

    2012-01-01

    The ability to effectively use a microscope to observe microorganisms is a crucial skill required for many disciplines within biology, especially general microbiology and cell biology. A basic understanding of the optical properties of light microscopes is required for students to use microscopes effectively, but this subject can also be a challenge to make personally interesting to students. To explore basic optical principles of magnification and resolving power in a more engaging and hands-on fashion, students constructed handmade lenses and microscopes based on Antony van Leeuwenhoek’s design using simple materials—paper, staples, glass, and adhesive putty. Students determined the power of their lenses using a green laser pointer to magnify a copper grid of known size, which also allowed students to examine variables affecting the power and resolution of a lens such as diameter, working distance, and wavelength of light. To assess the effectiveness of the laboratory’s learning objectives, four sections of a general microbiology course were given a brief pre-activity assessment quiz to determine their background knowledge on the subject. One week after the laboratory activity, students were given the same quiz (unannounced) under similar conditions. Students showed significant gains in their understanding of microscope optics. PMID:23653781

  3. Fidget spinners: Purported benefits, adverse effects and accepted alternatives.

    PubMed

    Schecter, Rachel A; Shah, Jay; Fruitman, Kate; Milanaik, Ruth Lynn

    2017-10-01

    In the span of a few months, fidget spinners have caught the eyes of millions of children, parents, educators and paediatricians. Fidget spinners, hand-held toys designed to spin freely in your grasp, have become a source of entertainment for consumers of all ages. Despite a lack of scientific evidence, toy marketers have advertised the benefits of fidget spinners for children with attention-deficit/hyperactivity disorder and other disorders (e.g. autism, anxiety, sensory issues). Parents are incentivized by these purported benefits to purchase fidget spinners to improve their child's concentration and decrease stress. While fidget spinners are a new phenomenon, existing therapy toys (e.g. sensory putty) have been used by occupational therapists for similar reasons, with comparably little research supporting these claims. The purpose of this review is to explore literature regarding sensory toys and examine educator/professional-reported concerns and medical adverse effects of using fidget spinners. Due to a recent surge in popularity, fidget spinners and other self-regulatory occupational therapy toys have yet to be subjected to rigorous scientific research. Thus, their alleged benefits remain scientifically unfounded. Paediatricians should be aware of potential choking hazards with this new fad, and inform parents that peer-reviewed studies do not support the beneficial claims.

  4. Comparative evaluation of the osteoinductivity of two formulations of human demineralized bone matrix.

    PubMed

    Takikawa, Satoshi; Bauer, Thomas W; Kambic, Helen; Togawa, Daisuke

    2003-04-01

    In the United States, demineralized bone matrix (DBM) is considered a transplantable tissue and therefore is regulated primarily by the American Association of Tissue Banks. Even though DBM is not subjected to the same regulations relative to performance claims as medical devices are, one would expect different processing methods might yield DBM preparations of different osteoinductive potential. The purpose of this study was to use an established athymic rat model to compare the osteoinductive properties of two commercially available human DBMs prepared using different methods but having essentially identical product claims. Sixteen female athymic rats were used to test equivalent volumes of two lots each of Grafton Putty (Osteotech, Inc., Eatontown, NJ), Osteofil (Regeneration Technologies, Inc., Alachua, FL), and rat DBM. At 28 days after implantation, qualitative and semiquantitative microscopy showed no significant differences in bone formation between the two lots from each source, but rat DBM produced significantly more bone than Grafton, which produced significantly more bone than Osteofil. Our results suggest that methods of graft processing may represent a greater source of variability than do differences among individual donors. Whether these differences relate to methods of demineralization, carrier, dose of DBM per volume, or to some other factor remains to be determined. Copyright 2003 Wiley Periodicals, Inc.

  5. Sensory aspects of drinking water in contact with epoxy lined copper pipe.

    PubMed

    Heim, T H; Dietrich, A M

    2007-01-01

    Pipe relining via in situ epoxy lining is used to remediate corroded plumbing or distribution systems. This investigation examined the effects on odour, TOC, THM formation and disinfectant demand in water exposed to epoxy-lined copper pipes used for home plumbing. The study was conducted in accordance with the Utility Quick Test, a migration/leaching method for utilities to conduct sensory analysis of materials in contact with drinking water. The test was performed using water with no disinfectant and levels of chlorine and monochloramines representative of those found in the distribution system. Panelists repeatedly and consistently described a "plastic/adhesive/putty" odour in the water from the pipes. The odour intensity remained relatively constant for each of two subsequent flushes. Water samples stored in the epoxy-lined pipes showed a significant increase in the leaching of organic compounds (as TOC), and this TOC was demonstrated to react with free chlorine to form trichloromethane. Water stored in the pipes also showed a marked increase in disinfectant demand relative to the water stored in glass control flasks. A study conducted at a full scale installation at an apartment demonstrated that after installation and regular use, the epoxy lining did not yield detectable differences in water quality.

  6. Localized ridge defect augmentation using human pericardium membrane and demineralized bone matrix.

    PubMed

    Vidyadharan, Arun Kumar; Ravindran, Anjana

    2014-01-01

    Patient wanted to restore her lost teeth with implants in the lower left first molar and second premolar region. Cone beam computerized tomography (CBCT) revealed inadequate bone width and height around future implant sites. The extraction socket of second premolar area revealed inadequate socket healing with sparse bone fill after 4 months of extraction. To evaluate the clinical feasibility of using a collagen physical resorbable barrier made of human pericardium (HP) to augment localized alveolar ridge defects for the subsequent placement of dental implants. Ridge augmentation was done in the compromised area using Puros® demineralized bone matrix (DBM) Putty with chips and an HP allograft membrane. Horizontal (width) and vertical hard tissue measurements with CBCT were recorded on the day of ridge augmentation surgery, 4 month and 7 months follow-up. Intra oral periapical taken 1 year after implant installation showed minimal crestal bone loss. Bone volume achieved through guided bone regeneration was a gain of 4.8 mm horizontally (width) and 6.8 mm vertically in the deficient ridge within a period of 7 months following the procedure. The results suggested that HP Allograft membrane may be a suitable component for augmentation of localized alveolar ridge defects in conjunction with DBM with bone chips.

  7. Effects of eye-glasses, hair, headgear, and clothing on measured head-related transfer functions Part Ib

    NASA Astrophysics Data System (ADS)

    Riederer, Klaus A. J.

    2003-10-01

    Extensive head-related transfer function (HRTF) measurements show high HRTF repeatability, consequences of different measurement methods, and conditions covering the whole three-dimensional space [Riederer, J. Audio Eng. Soc. (Abstracts) 46, 1036 (1998), preprint 4846]. This study concentrates on specific effects on HRTFs carefully re-measured on the same Cortex dummy head applying Sennheiser KE4-211-2 microphones at its silicone putty blocked ear-canal entrances, employing 252 sound incidents including seven elevations. The effects of five different wigs (synthetic, natural, thick, thin, long and short hair) with varied hairstyles, four hats (cap, bicycle helmet, mens and womens trilby), clothes (alpaca pullover, bicycling drymax-jacket) and spectacles were investigated under 28 combinations. The influences are highly dependent on direction, frequency, and case. Clothes and eye-glasses affect minimally HRTF; hair has a stronger effect, depending on the actual hairdo (typically above 7 kHz). Hats alter intensively HRTFs (typically above 5 kHz), depending on the model. The measurements give deeper insight to the development of idiosyncratic features in binaural localization cues. The second part of the study addresses their perceptual effects [Riederer, J. Acoust. Soc. Am., this issue]. [Work supported by Graduate School of Electronics, Telecommunication and Automation; thanks to Finnish Broadcasting Company, Mr. Hellstrom; Mrs. Chen.

  8. Prediction of the thermophysical properties of molten salt fast reactor fuel from first-principles

    NASA Astrophysics Data System (ADS)

    Gheribi, A. E.; Corradini, D.; Dewan, L.; Chartrand, P.; Simon, C.; Madden, P. A.; Salanne, M.

    2014-05-01

    Molten fluorides are known to show favourable thermophysical properties which make them good candidate coolants for nuclear fission reactors. Here we investigate the special case of mixtures of lithium fluoride and thorium fluoride, which act both as coolant and as fuel in the molten salt fast reactor concept. By using ab initio parameterised polarisable force fields, we show that it is possible to calculate the whole set of properties (density, thermal expansion, heat capacity, viscosity and thermal conductivity) which are necessary for assessing the heat transfer performance of the melt over the whole range of compositions and temperatures. We then deduce from our calculations several figures of merit which are important in helping the optimisation of the design of molten salt fast reactors.

  9. Sea ice classification using fast learning neural networks

    NASA Technical Reports Server (NTRS)

    Dawson, M. S.; Fung, A. K.; Manry, M. T.

    1992-01-01

    A first learning neural network approach to the classification of sea ice is presented. The fast learning (FL) neural network and a multilayer perceptron (MLP) trained with backpropagation learning (BP network) were tested on simulated data sets based on the known dominant scattering characteristics of the target class. Four classes were used in the data simulation: open water, thick lossy saline ice, thin saline ice, and multiyear ice. The BP network was unable to consistently converge to less than 25 percent error while the FL method yielded an average error of approximately 1 percent on the first iteration of training. The fast learning method presented can significantly reduce the CPU time necessary to train a neural network as well as consistently yield higher classification accuracy than BP networks.

  10. Variability of the volume and thickness of sea ice in the Bay of Bothnia

    NASA Astrophysics Data System (ADS)

    Ronkainen, Iina; Lehtiranta, Jonni; Lensu, Mikko; Rinne, Eero; Hordoir, Robinson; Haapala, Jari

    2017-04-01

    Variability of the volume and thickness of sea ice in the Bay of Bothnia In our study, we want to quantify the variability of sea ice volume and thickness in the Bay of Bothnia and to introduce the drivers of the observed variability. There has been similar studies, but only for fast ice. We use various different data sets: in-situ ice thickness data, remote sensing data, model data and ice charts. In-situ data is from the regular monitoring stations in the coastal fast ice zone and from field campaigns. The remote sensing data is helicopter-borne and ship-borne electromagnetic data. The models we use are HELMI and NEMO-Nordic. We analyze the different data sets and compare them to each other to solve the inter-annual variability and to discuss the ratio of level and deformed ice.

  11. Nonlinear model predictive control applied to the separation of praziquantel in simulated moving bed chromatography.

    PubMed

    Andrade Neto, A S; Secchi, A R; Souza, M B; Barreto, A G

    2016-10-28

    An adaptive nonlinear model predictive control of a simulated moving bed unit for the enantioseparation of praziquantel is presented. A first principle model was applied at the proposed purity control scheme. The main concern about this kind of model in a control framework is in regard to the computational effort to solve it; however, a fast enough solution was achieved. In order to evaluate the controller's performance, several cases were simulated, including external pumps and switching valve malfunctions. The problem of plant-model mismatch was also investigated, and for that reason a parameter estimation step was introduced in the control strategy. In every studied scenario, the controller was able to maintain the purity levels at their set points, which were set to 99% and 98.6% for extract and raffinate, respectively. Additionally, fast responses and smooth actuation were achieved. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. A Search for Neutrino Emission from Fast Radio Bursts with Six Years of IceCube Data

    NASA Astrophysics Data System (ADS)

    Aartsen, M. G.; Ackermann, M.; Adams, J.; Aguilar, J. A.; Ahlers, M.; Ahrens, M.; Samarai, I. Al; Altmann, D.; Andeen, K.; Anderson, T.; Ansseau, I.; Anton, G.; Argüelles, C.; Auffenberg, J.; Axani, S.; Bagherpour, H.; Bai, X.; Barron, J. P.; Barwick, S. W.; Baum, V.; Bay, R.; Beatty, J. J.; Becker Tjus, J.; Becker, K.-H.; BenZvi, S.; Berley, D.; Bernardini, E.; Besson, D. Z.; Binder, G.; Bindig, D.; Blaufuss, E.; Blot, S.; Bohm, C.; Börner, M.; Bos, F.; Böser, S.; Botner, O.; Bourbeau, E.; Bourbeau, J.; Bradascio, F.; Braun, J.; Brenzke, M.; Bretz, H.-P.; Bron, S.; Brostean-Kaiser, J.; Burgman, A.; Busse, R. S.; Carver, T.; Cheung, E.; Chirkin, D.; Christov, A.; Clark, K.; Classen, L.; Collin, G. H.; Conrad, J. M.; Coppin, P.; Correa, P.; Cowen, D. F.; Cross, R.; Dave, P.; Day, M.; de André, J. P. A. M.; De Clercq, C.; DeLaunay, J. J.; Dembinski, H.; De Ridder, S.; Desiati, P.; de Vries, K. D.; de Wasseige, G.; de With, M.; DeYoung, T.; Díaz-Vélez, J. C.; di Lorenzo, V.; Dujmovic, H.; Dumm, J. P.; Dunkman, M.; Dvorak, E.; Eberhardt, B.; Ehrhardt, T.; Eichmann, B.; Eller, P.; Evenson, P. A.; Fahey, S.; Fazely, A. R.; Felde, J.; Filimonov, K.; Finley, C.; Flis, S.; Franckowiak, A.; Friedman, E.; Fritz, A.; Gaisser, T. K.; Gallagher, J.; Gerhardt, L.; Ghorbani, K.; Giang, W.; Glauch, T.; Glüsenkamp, T.; Goldschmidt, A.; Gonzalez, J. G.; Grant, D.; Griffith, Z.; Haack, C.; Hallgren, A.; Halzen, F.; Hanson, K.; Hebecker, D.; Heereman, D.; Helbing, K.; Hellauer, R.; Hickford, S.; Hignight, J.; Hill, G. C.; Hoffman, K. D.; Hoffmann, R.; Hoinka, T.; Hokanson-Fasig, B.; Hoshina, K.; Huang, F.; Huber, M.; Hultqvist, K.; Hünnefeld, M.; Hussain, R.; In, S.; Iovine, N.; Ishihara, A.; Jacobi, E.; Japaridze, G. S.; Jeong, M.; Jero, K.; Jones, B. J. P.; Kalaczynski, P.; Kang, W.; Kappes, A.; Kappesser, D.; Karg, T.; Karle, A.; Katz, U.; Kauer, M.; Keivani, A.; Kelley, J. L.; Kheirandish, A.; Kim, J.; Kim, M.; Kintscher, T.; Kiryluk, J.; Kittler, T.; Klein, S. R.; Koirala, R.; Kolanoski, H.; Köpke, L.; Kopper, C.; Kopper, S.; Koschinsky, J. P.; Koskinen, D. J.; Kowalski, M.; Krings, K.; Kroll, M.; Krückl, G.; Kunwar, S.; Kurahashi, N.; Kuwabara, T.; Kyriacou, A.; Labare, M.; Lanfranchi, J. L.; Larson, M. J.; Lauber, F.; Leonard, K.; Lesiak-Bzdak, M.; Leuermann, M.; Liu, Q. R.; Lozano Mariscal, C. J.; Lu, L.; Lünemann, J.; Luszczak, W.; Madsen, J.; Maggi, G.; Mahn, K. B. M.; Mancina, S.; Maruyama, R.; Mase, K.; Maunu, R.; Meagher, K.; Medici, M.; Meier, M.; Menne, T.; Merino, G.; Meures, T.; Miarecki, S.; Micallef, J.; Momenté, G.; Montaruli, T.; Moore, R. W.; Moulai, M.; Nahnhauer, R.; Nakarmi, P.; Naumann, U.; Neer, G.; Niederhausen, H.; Nowicki, S. C.; Nygren, D. R.; Obertacke Pollmann, A.; Olivas, A.; O’Murchadha, A.; O’Sullivan, E.; Palczewski, T.; Pandya, H.; Pankova, D. V.; Peiffer, P.; Pepper, J. A.; Pérez de los Heros, C.; Pieloth, D.; Pinat, E.; Plum, M.; Price, P. B.; Przybylski, G. T.; Raab, C.; Rädel, L.; Rameez, M.; Rauch, L.; Rawlins, K.; Rea, I. C.; Reimann, R.; Relethford, B.; Relich, M.; Resconi, E.; Rhode, W.; Richman, M.; Robertson, S.; Rongen, M.; Rott, C.; Ruhe, T.; Ryckbosch, D.; Rysewyk, D.; Safa, I.; Sälzer, T.; Sanchez Herrera, S. E.; Sandrock, A.; Sandroos, J.; Santander, M.; Sarkar, S.; Sarkar, S.; Satalecka, K.; Schlunder, P.; Schmidt, T.; Schneider, A.; Schoenen, S.; Schöneberg, S.; Schumacher, L.; Sclafani, S.; Seckel, D.; Seunarine, S.; Soedingrekso, J.; Soldin, D.; Song, M.; Spiczak, G. M.; Spiering, C.; Stachurska, J.; Stamatikos, M.; Stanev, T.; Stasik, A.; Stein, R.; Stettner, J.; Steuer, A.; Stezelberger, T.; Stokstad, R. G.; Stößl, A.; Strotjohann, N. L.; Stuttard, T.; Sullivan, G. W.; Sutherland, M.; Taboada, I.; Tatar, J.; Tenholt, F.; Ter-Antonyan, S.; Terliuk, A.; Tilav, S.; Toale, P. A.; Tobin, M. N.; Tönnis, C.; Toscano, S.; Tosi, D.; Tselengidou, M.; Tung, C. F.; Turcati, A.; Turley, C. F.; Ty, B.; Unger, E.; Usner, M.; Vandenbroucke, J.; Van Driessche, W.; van Eijk, D.; van Eijndhoven, N.; Vanheule, S.; van Santen, J.; Vogel, E.; Vraeghe, M.; Walck, C.; Wallace, A.; Wallraff, M.; Wandler, F. D.; Wandkowsky, N.; Waza, A.; Weaver, C.; Weiss, M. J.; Wendt, C.; Werthebach, J.; Westerhoff, S.; Whelan, B. J.; Wiebe, K.; Wiebusch, C. H.; Wille, L.; Williams, D. R.; Wills, L.; Wolf, M.; Wood, J.; Wood, T. R.; Woolsey, E.; Woschnagg, K.; Xu, D. L.; Xu, X. W.; Xu, Y.; Yanez, J. P.; Yodh, G.; Yoshida, S.; Yuan, T.; IceCube Collaboration

    2018-04-01

    We present a search for coincidence between IceCube TeV neutrinos and fast radio bursts (FRBs). During the search period from 2010 May 31 to 2016 May 12, a total of 29 FRBs with 13 unique locations have been detected in the whole sky. An unbinned maximum likelihood method was used to search for spatial and temporal coincidence between neutrinos and FRBs in expanding time windows, in both the northern and southern hemispheres. No significant correlation was found in six years of IceCube data. Therefore, we set upper limits on neutrino fluence emitted by FRBs as a function of time window duration. We set the most stringent limit obtained to date on neutrino fluence from FRBs with an E ‑2 energy spectrum assumed, which is 0.0021 GeV cm‑2 per burst for emission timescales up to ∼102 s from the northern hemisphere stacking search.

  13. Hybrid method for moving interface problems with application to the Hele-Shaw flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hou, T.Y.; Li, Zhilin; Osher, S.

    In this paper, a hybrid approach which combines the immersed interface method with the level set approach is presented. The fast version of the immersed interface method is used to solve the differential equations whose solutions and their derivatives may be discontinuous across the interfaces due to the discontinuity of the coefficients or/and singular sources along the interfaces. The moving interfaces then are updated using the newly developed fast level set formulation which involves computation only inside some small tubes containing the interfaces. This method combines the advantage of the two approaches and gives a second-order Eulerian discretization for interfacemore » problems. Several key steps in the implementation are addressed in detail. This new approach is then applied to Hele-Shaw flow, an unstable flow involving two fluids with very different viscosity. 40 refs., 10 figs., 3 tabs.« less

  14. Precise and fast spatial-frequency analysis using the iterative local Fourier transform.

    PubMed

    Lee, Sukmock; Choi, Heejoo; Kim, Dae Wook

    2016-09-19

    The use of the discrete Fourier transform has decreased since the introduction of the fast Fourier transform (fFT), which is a numerically efficient computing process. This paper presents the iterative local Fourier transform (ilFT), a set of new processing algorithms that iteratively apply the discrete Fourier transform within a local and optimal frequency domain. The new technique achieves 210 times higher frequency resolution than the fFT within a comparable computation time. The method's superb computing efficiency, high resolution, spectrum zoom-in capability, and overall performance are evaluated and compared to other advanced high-resolution Fourier transform techniques, such as the fFT combined with several fitting methods. The effectiveness of the ilFT is demonstrated through the data analysis of a set of Talbot self-images (1280 × 1024 pixels) obtained with an experimental setup using grating in a diverging beam produced by a coherent point source.

  15. Vertical profiles of ozone, carbon monoxide, and dew-point temperature obtained during GTE/CITE 1, October-November 1983. [Chemical Instrumentation Test and Evaluation

    NASA Technical Reports Server (NTRS)

    Fishman, Jack; Gregory, Gerald L.; Sachse, Glen W.; Beck, Sherwin M.; Hill, Gerald F.

    1987-01-01

    A set of 14 pairs of vertical profiles of ozone and carbon monoxide, obtained with fast-response instrumentation, is presented. Most of these profiles, which were measured in the remote troposphere, also have supporting fast-response dew-point temperature profiles. The data suggest that the continental boundary layer is a source of tropospheric ozone, even in October and November, when photochemical activity should be rather small. In general, the small-scale vertical variability between CO and O3 is in phase. At low latitudes this relationship defines levels in the atmosphere where midlatitude air is being transported to lower latitudes, since lower dew-point temperatures accompany these higher CO and O3 concentrations. A set of profiles which is suggestive of interhemispheric transport is also presented. Independent meteorological analyses support these interpretations.

  16. INFFTM: Fast evaluation of 3d Fourier series in MATLAB with an application to quantum vortex reconnections

    NASA Astrophysics Data System (ADS)

    Caliari, Marco; Zuccher, Simone

    2017-04-01

    Although Fourier series approximation is ubiquitous in computational physics owing to the Fast Fourier Transform (FFT) algorithm, efficient techniques for the fast evaluation of a three-dimensional truncated Fourier series at a set of arbitrary points are quite rare, especially in MATLAB language. Here we employ the Nonequispaced Fast Fourier Transform (NFFT, by J. Keiner, S. Kunis, and D. Potts), a C library designed for this purpose, and provide a Matlab® and GNU Octave interface that makes NFFT easily available to the Numerical Analysis community. We test the effectiveness of our package in the framework of quantum vortex reconnections, where pseudospectral Fourier methods are commonly used and local high resolution is required in the post-processing stage. We show that the efficient evaluation of a truncated Fourier series at arbitrary points provides excellent results at a computational cost much smaller than carrying out a numerical simulation of the problem on a sufficiently fine regular grid that can reproduce comparable details of the reconnecting vortices.

  17. Fast correction approach for wavefront sensorless adaptive optics based on a linear phase diversity technique.

    PubMed

    Yue, Dan; Nie, Haitao; Li, Ye; Ying, Changsheng

    2018-03-01

    Wavefront sensorless (WFSless) adaptive optics (AO) systems have been widely studied in recent years. To reach optimum results, such systems require an efficient correction method. This paper presents a fast wavefront correction approach for a WFSless AO system mainly based on the linear phase diversity (PD) technique. The fast closed-loop control algorithm is set up based on the linear relationship between the drive voltage of the deformable mirror (DM) and the far-field images of the system, which is obtained through the linear PD algorithm combined with the influence function of the DM. A large number of phase screens under different turbulence strengths are simulated to test the performance of the proposed method. The numerical simulation results show that the method has fast convergence rate and strong correction ability, a few correction times can achieve good correction results, and can effectively improve the imaging quality of the system while needing fewer measurements of CCD data.

  18. BMSW - Fast Solar Wind Monitor - three years in orbit: Status and prospects

    NASA Astrophysics Data System (ADS)

    Prech, Lubomir; Zastenker, Georgy; Nemecek, Zdenek; Safrankova, Jana; Vaverka, Jakub; Cermak, Ivo; Chesalin, Lev S.; Gavrilova, Elena

    Fast Solar Wind Monitor BMSW is an instrument flown as a part of the PLASMA-F complex onboard the Russian Spektr-R radioastronomical spacecraft. The spacecraft was launched on July 18, 2011. During the COSPAR-2014 Assembly meeting, the instrument is supposed to celebrate three successful years in operation. With a set of 6 Faraday’s cups, the instrument has a unique time resolution --- 0.5--1 s for a full energy spectrum (96 energy steps) and 31~ms for basic solar wind plasma parameters directing the instrument to study of fast solar wind discontinuities including interplanetary shocks, a fast variability of proton and alpha particle parameters, and to study of solar wind turbulence up to the ion kinetic scales. The measurement technique, its implementation, and ground data processing are discussed in the contribution. The performance of the instrument design and electronics are presented. We discuss heritage of this instrument utilized in design of future instruments being prepared for the further projects as Luna-Glob.

  19. The Modulation of Exogenous Spatial Cueing on Spatial Stroop Interference: Evidence of a Set for "Cue-Target Event Segregation"

    ERIC Educational Resources Information Center

    Funes, Maria Jesus; Lupianez, Juan; Milliken, Bruce

    2008-01-01

    Two experiments are reported that test whether the modulation of exogenous cuing effects by the presence of a distractor at the location opposite the target (altering the time course of cueing effects, Lupianez et al., 1999, 2001) is due to the fast reorienting of attention or to a set for preventing the integration of the cue and the target…

  20. CALIBRATION OF SEMI-ANALYTIC MODELS OF GALAXY FORMATION USING PARTICLE SWARM OPTIMIZATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruiz, Andrés N.; Domínguez, Mariano J.; Yaryura, Yamila

    2015-03-10

    We present a fast and accurate method to select an optimal set of parameters in semi-analytic models of galaxy formation and evolution (SAMs). Our approach compares the results of a model against a set of observables applying a stochastic technique called Particle Swarm Optimization (PSO), a self-learning algorithm for localizing regions of maximum likelihood in multidimensional spaces that outperforms traditional sampling methods in terms of computational cost. We apply the PSO technique to the SAG semi-analytic model combined with merger trees extracted from a standard Lambda Cold Dark Matter N-body simulation. The calibration is performed using a combination of observedmore » galaxy properties as constraints, including the local stellar mass function and the black hole to bulge mass relation. We test the ability of the PSO algorithm to find the best set of free parameters of the model by comparing the results with those obtained using a MCMC exploration. Both methods find the same maximum likelihood region, however, the PSO method requires one order of magnitude fewer evaluations. This new approach allows a fast estimation of the best-fitting parameter set in multidimensional spaces, providing a practical tool to test the consequences of including other astrophysical processes in SAMs.« less

  1. Monitoring the changes to the nutrient composition of fast foods following the introduction of menu labelling in New South Wales, Australia: an observational study.

    PubMed

    Wellard-Cole, Lyndal; Goldsbury, David; Havill, Michelle; Hughes, Clare; Watson, Wendy L; Dunford, Elizabeth K; Chapman, Kathy

    2018-04-01

    The present study examined the energy (kilojoule) content of Australian fast-food menu items over seven years, before and after introduction of menu board labelling, to determine the impact of the introduction of the legislation. Analysis of the median energy contents per serving and per 100g of fast-food menu items. Change in energy content of menu items across the years surveyed and differences in energy content of standard and limited-time only menu items were analysed. Five of Australia's largest fast food chains: Hungry Jack's, KFC, McDonald's, Oporto and Red Rooster. All standard and limited-time only menu items available at each fast-food chain, collected annually for seven years, 2009-2015. Although some fast-food chains/menu item categories had significant increases in the energy contents of their menus at some time points during the 7-year period, overall there were no significant or systematic decreases in energy following the introduction of menu labelling (P=0·19 by +17 kJ/100 g, P=0·83 by +8 kJ/serving). Limited-time only items were significantly higher in median energy content per 100 g than standard menu items (+74 kJ/100 g, P=0·002). While reformulation across the entire Australian fast-food supply has the potential to positively influence population nutrient intake, the introduction of menu labelling legislation in New South Wales, Australia did not lead to reduced energy contents across the five fast-food chains. To encourage widespread reformulation by the fast-food industry and enhance the impact of labelling legislation, the government should work with industry to set targets for reformulation of nutrient content.

  2. Development of a fast PCR protocol enabling rapid generation of AmpFℓSTR® Identifiler® profiles for genotyping of human DNA

    PubMed Central

    2012-01-01

    Background Traditional PCR methods for forensic STR genotyping require approximately 2.5 to 4 hours to complete, contributing a significant portion of the time required to process forensic DNA samples. The purpose of this study was to develop and validate a fast PCR protocol that enabled amplification of the 16 loci targeted by the AmpFℓSTR® Identifiler® primer set, allowing decreased cycling times. Methods Fast PCR conditions were achieved by substituting the traditional Taq polymerase for SpeedSTAR™ HS DNA polymerase which is designed for fast PCR, by upgrading to a thermal cycler with faster temperature ramping rates and by modifying cycling parameters (less time at each temperature) and adopting a two-step PCR approach. Results The total time required for the optimized protocol is 26 min. A total of 147 forensically relevant DNA samples were amplified using the fast PCR protocol for Identifiler. Heterozygote peak height ratios were not affected by fast PCR conditions, and full profiles were generated for single-source DNA amounts between 0.125 ng and 2.0 ng. Individual loci in profiles produced with the fast PCR protocol exhibited average n-4 stutter percentages ranging from 2.5 ± 0.9% (THO1) to 9.9 ± 2.7% (D2S1338). No increase in non-adenylation or other amplification artefacts was observed. Minor contributor alleles in two-person DNA mixtures were reliably discerned. Low level cross-reactivity (monomorphic peaks) was observed with some domestic animal DNA. Conclusions The fast PCR protocol presented offers a feasible alternative to current amplification methods and could aid in reducing the overall time in STR profile production or could be incorporated into a fast STR genotyping procedure for time-sensitive situations. PMID:22394458

  3. Development of a fast PCR protocol enabling rapid generation of AmpFℓSTR® Identifiler® profiles for genotyping of human DNA.

    PubMed

    Foster, Amanda; Laurin, Nancy

    2012-03-06

    Traditional PCR methods for forensic STR genotyping require approximately 2.5 to 4 hours to complete, contributing a significant portion of the time required to process forensic DNA samples. The purpose of this study was to develop and validate a fast PCR protocol that enabled amplification of the 16 loci targeted by the AmpFℓSTR® Identifiler® primer set, allowing decreased cycling times. Fast PCR conditions were achieved by substituting the traditional Taq polymerase for SpeedSTAR™ HS DNA polymerase which is designed for fast PCR, by upgrading to a thermal cycler with faster temperature ramping rates and by modifying cycling parameters (less time at each temperature) and adopting a two-step PCR approach. The total time required for the optimized protocol is 26 min. A total of 147 forensically relevant DNA samples were amplified using the fast PCR protocol for Identifiler. Heterozygote peak height ratios were not affected by fast PCR conditions, and full profiles were generated for single-source DNA amounts between 0.125 ng and 2.0 ng. Individual loci in profiles produced with the fast PCR protocol exhibited average n-4 stutter percentages ranging from 2.5 ± 0.9% (THO1) to 9.9 ± 2.7% (D2S1338). No increase in non-adenylation or other amplification artefacts was observed. Minor contributor alleles in two-person DNA mixtures were reliably discerned. Low level cross-reactivity (monomorphic peaks) was observed with some domestic animal DNA. The fast PCR protocol presented offers a feasible alternative to current amplification methods and could aid in reducing the overall time in STR profile production or could be incorporated into a fast STR genotyping procedure for time-sensitive situations.

  4. Ischemia-reperfusion injury in rat fatty liver: role of nutritional status.

    PubMed

    Caraceni, P; Nardo, B; Domenicali, M; Turi, P; Vici, M; Simoncini, M; De Maria, N; Trevisani, F; Van Thiel, D H; Derenzini, M; Cavallari, A; Bernardi, M

    1999-04-01

    Fatty livers are more sensitive to the deleterious effects of ischemia-reperfusion than normal livers. Nutritional status greatly modulates this injury in normal livers, but its role in the specific setting of fatty liver is unknown. This study aimed to determine the effect of nutritional status on warm ischemia-reperfusion injury in rat fatty livers. Fed and fasted rats with normal or fatty liver induced by a choline deficient diet underwent 1 hour of lobar ischemia and reperfusion. Rat survival was determined for 7 days. Serum transaminases, liver histology and cell ultrastructure were assessed before and after ischemia, and at 30 minutes, 2 hours, 8 hours, and 24 hours after reperfusion. Survival was also determined in fatty fasted rats supplemented with glucose before surgery. The preischemic hepatic glycogen was measured in all groups. Whereas survival was similar in fasted and fed rats with normal liver (90% vs. 100%), fasting dramatically reduced survival in rats with fatty liver (14% vs. 64%, P <.01). Accordingly, fasting and fatty degeneration had a synergistic effect in exacerbating liver injury. Mitochondrial damage was a predominant feature of ultrastructural hepatocyte injury in fasted fatty livers. Glucose supplementation partially prevented the fasting-induced depletion of glycogen and improved the 7-day rat survival to 45%. These data indicate that rat fatty livers exposed to normothermic ischemia-reperfusion injury are much more sensitive to fasting than histologically normal livers. Because glucose supplementation improves both the hepatic glycogen stores and the rat survival, a nutritional repletion procedure may be part of a treatment strategy aimed to prevent ischemia-reperfusion injury in fatty livers.

  5. Fast Food Consumption Pattern and Its Association with Overweight Among High School Boys in Mangalore City of Southern India.

    PubMed

    Joseph, Nitin; Nelliyanil, Maria; Rai, Sharada; Y P, Raghavendra Babu; Kotian, Shashidhar M; Ghosh, Tanima; Singh, Manisha

    2015-05-01

    Fast foods are quite popular among children owing to taste, appearance and hype created by mass media. However, the increased incidence of lifestyle disorders seen now-a-days at an early age could be attributed to fast foods. This study was done to assess the awareness of health hazards, consumption pattern of fast foods and to find out its association with overweight among high school students. This cross-sectional study was done among boys of 3 private schools in Mangalore city in March 2012. Data was collected using a semi-structured self-administered questionnaire. Chi-square test, one-way ANOVA and binary logistic regression analysis was used for analysis. P-value ≤ 0.05 was considered as statistically significant association. Mean age of boys was 13.5±0.9 years. Out of 300 participants, 41(13.7%) were overweight and 8 (2.7%) were obese. 292(97.3%) were fast food users of which 42(14.4%) consumed it every day. Majority of participants were introduced to fast foods through television commercials 193(64.3%). 73(57%) developed this habit as they were bored with home food. Awareness of harmful effects of fast food consumption was known to 186(62%) students and this was found to be associated with the perceived need to control its usage (p<0.001). Parental consumption of fast foods was found to influence fast food consumption among children (p=0.024). As many as 68(22.7%) and 206(68.7%) children were not eating vegetables and fruits respectively every day. Increased frequency of fast food consumption in a week was found to be associated with overweight or obesity among children after adjusting the effects of confounders (p=0.003). Awareness on health hazards of fast foods needs to be taught at schools so as to minimize its consumption. Parents have to set an example themselves by not eating fast foods and improving home food to support discouragement of fast foods. This would minimize life style disorders among children to a greater extent.

  6. OBLIMAP 2.0: a fast climate model-ice sheet model coupler including online embeddable mapping routines

    NASA Astrophysics Data System (ADS)

    Reerink, Thomas J.; van de Berg, Willem Jan; van de Wal, Roderik S. W.

    2016-11-01

    This paper accompanies the second OBLIMAP open-source release. The package is developed to map climate fields between a general circulation model (GCM) and an ice sheet model (ISM) in both directions by using optimal aligned oblique projections, which minimize distortions. The curvature of the surfaces of the GCM and ISM grid differ, both grids may be irregularly spaced and the ratio of the grids is allowed to differ largely. OBLIMAP's stand-alone version is able to map data sets that differ in various aspects on the same ISM grid. Each grid may either coincide with the surface of a sphere, an ellipsoid or a flat plane, while the grid types might differ. Re-projection of, for example, ISM data sets is also facilitated. This is demonstrated by relevant applications concerning the major ice caps. As the stand-alone version also applies to the reverse mapping direction, it can be used as an offline coupler. Furthermore, OBLIMAP 2.0 is an embeddable GCM-ISM coupler, suited for high-frequency online coupled experiments. A new fast scan method is presented for structured grids as an alternative for the former time-consuming grid search strategy, realising a performance gain of several orders of magnitude and enabling the mapping of high-resolution data sets with a much larger number of grid nodes. Further, a highly flexible masked mapping option is added. The limitation of the fast scan method with respect to unstructured and adaptive grids is discussed together with a possible future parallel Message Passing Interface (MPI) implementation.

  7. Experience with DPP-4 inhibitors in the management of patients with type 2 diabetes fasting during Ramadan

    PubMed Central

    Schweizer, Anja; Halimi, Serge; Dejager, Sylvie

    2014-01-01

    A large proportion of Muslim patients with type 2 diabetes mellitus (T2DM) elect to fast during the holy month of Ramadan. For these patients hypo- and hyperglycemia constitute two major complications associated with the profound changes in food pattern during the Ramadan fast, and efficacious treatment options with a low risk of hypoglycemia are therefore needed to manage their T2DM as effectively and safely as possible. Dipeptidyl peptidase-4 (DPP-4) inhibitors modulate insulin and glucagon secretion in a glucose-dependent manner, and consequently a low propensity of hypoglycemia has consistently been reported across different patient populations with these agents. Promising data with DPP-4 inhibitors have now also started to emerge in patients with T2DM fasting during Ramadan. The objective of this review is to provide a comprehensive overview of the currently available evidence and potential role of DPP-4 inhibitors in the management of patients with T2DM fasting during Ramadan whose diabetes is treated with oral antidiabetic drugs, and to discuss the mechanistic basis for their beneficial effects in this setting. PMID:24391442

  8. Supplemental Interscalene Blockade to General Anesthesia for Shoulder Arthroscopy: Effects on Fast Track Capability, Analgesic Quality, and Lung Function.

    PubMed

    Zoremba, Martin; Kratz, Thomas; Dette, Frank; Wulf, Hinnerk; Steinfeldt, Thorsten; Wiesmann, Thomas

    2015-01-01

    After shoulder surgery performed in patients with interscalene nerve block (without general anesthesia), fast track capability and postoperative pain management in the PACU are improved compared with general anesthesia alone. However, it is not known if these evidence-based benefits still exist when the interscalene block is combined with general anesthesia. We retrospectively analyzed a prospective cohort data set of 159 patients undergoing shoulder arthroscopy with general anesthesia alone (n = 60) or combined with an interscalene nerve block catheter (n = 99) for fast track capability time. Moreover, comparisons were made for VAS scores, analgesic consumption in the PACU, pain management, and lung function measurements. The groups did not differ in mean time to fast track capability (22 versus 22 min). Opioid consumption in PACU was significantly less in the interscalene group, who had significantly better VAS scores during PACU stay. Patients receiving interscalene blockade had a significantly impaired lung function postoperatively, although this did not affect postoperative recovery and had no impact on PACU times. The addition of interscalene block to general anesthesia for shoulder arthroscopy did not enhance fast track capability. Pain management and VAS scores were improved in the interscalene nerve block group.

  9. FAST TRACK COMMUNICATION Initial data for the relativistic gravitational N-body problem

    NASA Astrophysics Data System (ADS)

    Chruściel, Piotr T.; Corvino, Justin; Isenberg, James

    2010-11-01

    In general relativity, an initial data set for an isolated gravitational system takes the form of a solution of the Einstein constraint equations which is asymptotically Euclidean on a specified end. Given a collection of N such data sets with a subregion of interest (bounded away from the specified end) chosen in each, we show that there exists a family of new initial data sets, each of which contains exact copies of each of the N chosen subregions, positioned in a chosen array in a single asymptotic end. These composite initial data sets model isolated, relativistic gravitational systems containing N chosen bodies in specified initial configurations.

  10. Inverse multipath fingerprinting for millimeter wave V2I beam alignment.

    DOT National Transportation Integrated Search

    2017-05-01

    Efficient beam alignment is a crucial component in millimeter wave systems with analog beamforming, especially in fast-changing vehicular settings. This paper uses the vehicles position (e.g., available via GPS) to query the multipath fingerprint ...

  11. Exposure to food advertising on television: associations with children's fast food and soft drink consumption and obesity.

    PubMed

    Andreyeva, Tatiana; Kelly, Inas Rashad; Harris, Jennifer L

    2011-07-01

    There is insufficient research on the direct effects of food advertising on children's diet and diet-related health, particularly in non-experimental settings. We employ a nationally-representative sample from the Early Childhood Longitudinal Survey-Kindergarten Cohort (ECLS-K) and the Nielsen Company data on spot television advertising of cereals, fast food restaurants and soft drinks to children across the top 55 designated-market areas to estimate the relation between exposure to food advertising on television and children's food consumption and body weight. Our results suggest that soft drink and fast food television advertising is associated with increased consumption of soft drinks and fast food among elementary school children (Grade 5). Exposure to 100 incremental TV ads for sugar-sweetened carbonated soft drinks during 2002-2004 was associated with a 9.4% rise in children's consumption of soft drinks in 2004. The same increase in exposure to fast food advertising was associated with a 1.1% rise in children's consumption of fast food. There was no detectable link between advertising exposure and average body weight, but fast food advertising was significantly associated with body mass index for overweight and obese children (≥85th BMI percentile), revealing detectable effects for a vulnerable group of children. Exposure to advertising for calorie-dense nutrient-poor foods may increase overall consumption of unhealthy food categories. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Restoring integrity--A grounded theory of coping with a fast track surgery programme.

    PubMed

    Jørgensen, Lene Bastrup; Fridlund, Bengt

    2016-01-01

    The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. The study design used classical grounded theory. The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients' main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme.

  13. Fast-food menu offerings vary in dietary quality, but are consistently poor.

    PubMed

    Kirkpatrick, Sharon I; Reedy, Jill; Kahle, Lisa L; Harris, Jennifer L; Ohri-Vachaspati, Punam; Krebs-Smith, Susan M

    2014-04-01

    To evaluate five popular fast-food chains' menus in relation to dietary guidance. Menus posted on chains' websites were coded using the Food and Nutrient Database for Dietary Studies and MyPyramid Equivalents Database to enable Healthy Eating Index-2005 (HEI-2005) scores to be assigned. Dollar or value and kids' menus and sets of items promoted as healthy or nutritious were also assessed. Five popular fast-food chains in the USA. Not applicable. Full menus scored lower than 50 out of 100 possible points on the HEI-2005. Scores for Total Fruit, Whole Grains and Sodium were particularly dismal. Compared with full menus, scores on dollar or value menus were 3 points higher on average, whereas kids' menus scored 10 points higher on average. Three chains marketed subsets of items as healthy or nutritious; these scored 17 points higher on average compared with the full menus. No menu or subset of menu items received a score higher than 72 out of 100 points. The poor quality of fast-food menus is a concern in light of increasing away-from-home eating, aggressive marketing to children and minorities, and the tendency for fast-food restaurants to be located in low-income and minority areas. The addition of fruits, vegetables and legumes; replacement of refined with whole grains; and reformulation of offerings high in sodium, solid fats and added sugars are potential strategies to improve fast-food offerings. The HEI may be a useful metric for ongoing monitoring of fast-food menus.

  14. Validity of the top-down approach of inverse dynamics analysis in fast and large rotational trunk movements.

    PubMed

    Iino, Yoichi; Kojima, Takeji

    2012-08-01

    This study investigated the validity of the top-down approach of inverse dynamics analysis in fast and large rotational movements of the trunk about three orthogonal axes of the pelvis for nine male collegiate students. The maximum angles of the upper trunk relative to the pelvis were approximately 47°, 49°, 32°, and 55° for lateral bending, flexion, extension, and axial rotation, respectively, with maximum angular velocities of 209°/s, 201°/s, 145°/s, and 288°/s, respectively. The pelvic moments about the axes during the movements were determined using the top-down and bottom-up approaches of inverse dynamics and compared between the two approaches. Three body segment inertial parameter sets were estimated using anthropometric data sets (Ae et al., Biomechanism 11, 1992; De Leva, J Biomech, 1996; Dumas et al., J Biomech, 2007). The root-mean-square errors of the moments and the absolute errors of the peaks of the moments were generally smaller than 10 N·m. The results suggest that the pelvic moment in motions involving fast and large trunk movements can be determined with a certain level of validity using the top-down approach in which the trunk is modeled as two or three rigid-link segments.

  15. Adiabatic fast passage application in solid state NMR study of cross relaxation and molecular dynamics in heteronuclear systems.

    PubMed

    Baranowski, M; Woźniak-Braszak, A; Jurga, K

    2016-01-01

    The paper presents the benefits of using fast adiabatic passage for the study of molecular dynamics in the solid state heteronuclear systems in the laboratory frame. A homemade pulse spectrometer operating at the frequency of 30.2MHz and 28.411MHz for protons and fluorines, respectively, has been enhanced with microcontroller direct digital synthesizer DDS controller [1-4]. This work briefly describes how to construct a low-cost and easy-to-assemble adiabatic extension set for homemade and commercial spectrometers based on recently very popular Arduino shields. The described set was designed for fast adiabatic generation. Timing and synchronization problems are discussed. The cross-relaxation experiments with different initial states of the two spin systems have been performed. Contrary to our previous work [5] where the steady-state NOE experiments were conducted now proton spins (1)H are polarized in the magnetic field B0 while fluorine spins (19)F are perturbed by selective saturation for a short time and then the system is allowed to evolve for a period in the absence of a saturating field. The adiabatic passage application leads to a reversal of magnetization of fluorine spins and increases the amplitude of the signal. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Cortical Specializations Underlying Fast Computations

    PubMed Central

    Volgushev, Maxim

    2016-01-01

    The time course of behaviorally relevant environmental events sets temporal constraints on neuronal processing. How does the mammalian brain make use of the increasingly complex networks of the neocortex, while making decisions and executing behavioral reactions within a reasonable time? The key parameter determining the speed of computations in neuronal networks is a time interval that neuronal ensembles need to process changes at their input and communicate results of this processing to downstream neurons. Theoretical analysis identified basic requirements for fast processing: use of neuronal populations for encoding, background activity, and fast onset dynamics of action potentials in neurons. Experimental evidence shows that populations of neocortical neurons fulfil these requirements. Indeed, they can change firing rate in response to input perturbations very quickly, within 1 to 3 ms, and encode high-frequency components of the input by phase-locking their spiking to frequencies up to 300 to 1000 Hz. This implies that time unit of computations by cortical ensembles is only few, 1 to 3 ms, which is considerably faster than the membrane time constant of individual neurons. The ability of cortical neuronal ensembles to communicate on a millisecond time scale allows for complex, multiple-step processing and precise coordination of neuronal activity in parallel processing streams, while keeping the speed of behavioral reactions within environmentally set temporal constraints. PMID:25689988

  17. Ambulatory Treatment of Fast Breathing in Young Infants Aged <60 Days: A Double-Blind, Randomized, Placebo-Controlled Equivalence Trial in Low-Income Settlements of Karachi

    PubMed Central

    Muhammad, Amber A.; Shafiq, Yasir; Shah, Saima; Kumar, Naresh; Ahmed, Imran; Azam, Iqbal; Pasha, Omrana; Zaidi, Anita K. M.

    2017-01-01

    Abstract Background. Integrated Management of Childhood Illness recommends that young infants with isolated fast breathing be referred to a hospital for antibiotic treatment, which is often impractical in resource-limited settings. Additionally, antibiotics may be unnecessary for physiologic tachypnea in otherwise well newborns. We tested the hypothesis that ambulatory treatment with oral amoxicillin for 7 days was equivalent (similarity margin of 3%) to placebo in young infants with isolated fast breathing in primary care settings where hospital referral is often unfeasible. Methods. This randomized equivalence trial was conducted in 4 primary health centers of Karachi, Pakistan. Infants presenting with isolated fast breathing and oxygen saturation ≥90% were randomly assigned to receive either oral amoxicillin or placebo twice daily for 7 days. Enrolled infants were followed on days 1–8, 11, and 14. The primary outcome was treatment failure by day 8, analyzed per protocol. The trial was stopped by the data safety monitoring board due to higher treatment failure rate and the occurrence of 2 deaths in the placebo arm in an interim analysis. Results. Four hundred twenty-three infants fulfilled per protocol criteria in the amoxicillin arm and 426 in the placebo arm. Twelve infants (2.8%) had treatment failure in the amoxicillin arm and 25 (5.9%) in the placebo arm (risk difference, 3.1; P value .04). Two infants in the placebo arm died, whereas no deaths occurred in the amoxicillin arm. Other adverse outcomes, as well as the proportions of relapse, were evenly distributed across both study arms. Conclusions. This trial failed to show equivalence of placebo to amoxicillin in the management of isolated fast breathing without hypoxemia or other clinical signs of illness in term young infants. Clinical Trials Registration. NCT01533818. PMID:27941119

  18. Micro-Bunched Beam Production at FAST for Narrow Band THz Generation Using a Slit-Mask

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hyun, J.; Crawford, D.; Edstrom Jr, D.

    We discuss simulations and experiments on creating micro-bunch beams for generating narrow band THz radiation at the Fermilab Accelerator Science and Technology (FAST) facility. The low-energy electron beamline at FAST consists of a photoinjector-based RF gun, two Lband superconducting accelerating cavities, a chicane, and a beam dump. The electron bunches are lengthened with cavity phases set off-crest for better longitudinal separation and then micro-bunched with a slit-mask installed in the chicane. We carried out the experiments with 30 MeV electron beams and detected signals of the micro-bunching using a skew quadrupole magnet in the chicane. In this paper, the detailsmore » of micro-bunch beam production, the detection of micro-bunching and comparison with simulations are described.« less

  19. 1 μs broadband frequency sweeping reflectometry for plasma density and fluctuation profile measurements

    NASA Astrophysics Data System (ADS)

    Clairet, F.; Bottereau, C.; Medvedeva, A.; Molina, D.; Conway, G. D.; Silva, A.; Stroth, U.; ASDEX Upgrade Team; Tore Supra Team; Eurofusion Mst1 Team

    2017-11-01

    Frequency swept reflectometry has reached the symbolic value of 1 μs sweeping time; this performance has been made possible, thanks to an improved control of the ramp voltage driving the frequency source. In parallel, the memory depth of the acquisition system has been upgraded and can provide up to 200 000 signals during a plasma discharge. Additional improvements regarding the trigger delay determination of the acquisition and the voltage ramp linearity required by this ultra-fast technique have been set. While this diagnostic is traditionally dedicated to the plasma electron density profile measurement, such a fast sweeping rate can provide the study of fast plasma events and turbulence with unprecedented time and radial resolution from the edge to the core. Experimental results obtained on ASDEX Upgrade plasmas are presented to demonstrate the performances of the diagnostic.

  20. Field Assessment Stroke Triage for Emergency Destination: A Simple and Accurate Prehospital Scale to Detect Large Vessel Occlusion Strokes.

    PubMed

    Lima, Fabricio O; Silva, Gisele S; Furie, Karen L; Frankel, Michael R; Lev, Michael H; Camargo, Érica C S; Haussen, Diogo C; Singhal, Aneesh B; Koroshetz, Walter J; Smith, Wade S; Nogueira, Raul G

    2016-08-01

    Patients with large vessel occlusion strokes (LVOS) may be better served by direct transfer to endovascular capable centers avoiding hazardous delays between primary and comprehensive stroke centers. However, accurate stroke field triage remains challenging. We aimed to develop a simple field scale to identify LVOS. The Field Assessment Stroke Triage for Emergency Destination (FAST-ED) scale was based on items of the National Institutes of Health Stroke Scale (NIHSS) with higher predictive value for LVOS and tested in the Screening Technology and Outcomes Project in Stroke (STOPStroke) cohort, in which patients underwent computed tomographic angiography within the first 24 hours of stroke onset. LVOS were defined by total occlusions involving the intracranial internal carotid artery, middle cerebral artery-M1, middle cerebral artery-2, or basilar arteries. Patients with partial, bihemispheric, and anterior+posterior circulation occlusions were excluded. Receiver operating characteristic curve, sensitivity, specificity, positive predictive value, and negative predictive value of FAST-ED were compared with the NIHSS, Rapid Arterial Occlusion Evaluation (RACE) scale, and Cincinnati Prehospital Stroke Severity (CPSS) scale. LVO was detected in 240 of the 727 qualifying patients (33%). FAST-ED had comparable accuracy to predict LVO to the NIHSS and higher accuracy than RACE and CPSS (area under the receiver operating characteristic curve: FAST-ED=0.81 as reference; NIHSS=0.80, P=0.28; RACE=0.77, P=0.02; and CPSS=0.75, P=0.002). A FAST-ED ≥4 had sensitivity of 0.60, specificity of 0.89, positive predictive value of 0.72, and negative predictive value of 0.82 versus RACE ≥5 of 0.55, 0.87, 0.68, and 0.79, and CPSS ≥2 of 0.56, 0.85, 0.65, and 0.78, respectively. FAST-ED is a simple scale that if successfully validated in the field, it may be used by medical emergency professionals to identify LVOS in the prehospital setting enabling rapid triage of patients. © 2016 American Heart Association, Inc.

  1. Enhancing Performance and Bit Rates in a Brain-Computer Interface System With Phase-to-Amplitude Cross-Frequency Coupling: Evidences From Traditional c-VEP, Fast c-VEP, and SSVEP Designs.

    PubMed

    Dimitriadis, Stavros I; Marimpis, Avraam D

    2018-01-01

    A brain-computer interface (BCI) is a channel of communication that transforms brain activity into specific commands for manipulating a personal computer or other home or electrical devices. In other words, a BCI is an alternative way of interacting with the environment by using brain activity instead of muscles and nerves. For that reason, BCI systems are of high clinical value for targeted populations suffering from neurological disorders. In this paper, we present a new processing approach in three publicly available BCI data sets: (a) a well-known multi-class ( N = 6) coded-modulated Visual Evoked potential (c-VEP)-based BCI system for able-bodied and disabled subjects; (b) a multi-class ( N = 32) c-VEP with slow and fast stimulus representation; and (c) a steady-state Visual Evoked potential (SSVEP) multi-class ( N = 5) flickering BCI system. Estimating cross-frequency coupling (CFC) and namely δ-θ [δ: (0.5-4 Hz), θ: (4-8 Hz)] phase-to-amplitude coupling (PAC) within sensor and across experimental time, we succeeded in achieving high classification accuracy and Information Transfer Rates (ITR) in the three data sets. Our approach outperformed the originally presented ITR on the three data sets. The bit rates obtained for both the disabled and able-bodied subjects reached the fastest reported level of 324 bits/min with the PAC estimator. Additionally, our approach outperformed alternative signal features such as the relative power (29.73 bits/min) and raw time series analysis (24.93 bits/min) and also the original reported bit rates of 10-25 bits/min . In the second data set, we succeeded in achieving an average ITR of 124.40 ± 11.68 for the slow 60 Hz and an average ITR of 233.99 ± 15.75 for the fast 120 Hz. In the third data set, we succeeded in achieving an average ITR of 106.44 ± 8.94. Current methodology outperforms any previous methodologies applied to each of the three free available BCI datasets.

  2. Factors contributing to the temperature beneath plaster or fiberglass cast material

    PubMed Central

    Hutchinson, Michael J; Hutchinson, Mark R

    2008-01-01

    Background Most cast materials mature and harden via an exothermic reaction. Although rare, thermal injuries secondary to casting can occur. The purpose of this study was to evaluate factors that contribute to the elevated temperature beneath a cast and, more specifically, evaluate the differences of modern casting materials including fiberglass and prefabricated splints. Methods The temperature beneath various types (plaster, fiberglass, and fiberglass splints), brands, and thickness of cast material were measured after they were applied over thermometer which was on the surface of a single diameter and thickness PVC tube. A single layer of cotton stockinette with variable layers and types of cast padding were placed prior to application of the cast. Serial temperature measurements were made as the cast matured and reached peak temperature. Time to peak, duration of peak, and peak temperature were noted. Additional tests included varying the dip water temperature and assessing external insulating factors. Ambient temperature, ambient humidity and dip water freshness were controlled. Results Outcomes revealed that material type, cast thickness, and dip water temperature played key roles regarding the temperature beneath the cast. Faster setting plasters achieved peak temperature quicker and at a higher level than slower setting plasters. Thicker fiberglass and plaster casts led to greater peak temperature levels. Likewise increasing dip-water temperature led to elevated temperatures. The thickness and type of cast padding had less of an effect for all materials. With a definition of thermal injury risk of skin injury being greater than 49 degrees Celsius, we found that thick casts of extra fast setting plaster consistently approached dangerous levels (greater than 49 degrees for an extended period). Indeed a cast of extra-fast setting plaster, 20 layers thick, placed on a pillow during maturation maintained temperatures over 50 degrees of Celsius for over 20 minutes. Conclusion Clinicians should be cautious when applying thick casts with warm dip water. Fast setting plasters have increased risk of thermal injury while brand does not appear to play a significant role. Prefabricated fiberglass splints appear to be safer than circumferential casts. The greatest risk of thermal injury occurs when thick casts are allowed to mature while resting on pillow. PMID:18298851

  3. Earthquake detection through computationally efficient similarity search

    PubMed Central

    Yoon, Clara E.; O’Reilly, Ossian; Bergen, Karianne J.; Beroza, Gregory C.

    2015-01-01

    Seismology is experiencing rapid growth in the quantity of data, which has outpaced the development of processing algorithms. Earthquake detection—identification of seismic events in continuous data—is a fundamental operation for observational seismology. We developed an efficient method to detect earthquakes using waveform similarity that overcomes the disadvantages of existing detection methods. Our method, called Fingerprint And Similarity Thresholding (FAST), can analyze a week of continuous seismic waveform data in less than 2 hours, or 140 times faster than autocorrelation. FAST adapts a data mining algorithm, originally designed to identify similar audio clips within large databases; it first creates compact “fingerprints” of waveforms by extracting key discriminative features, then groups similar fingerprints together within a database to facilitate fast, scalable search for similar fingerprint pairs, and finally generates a list of earthquake detections. FAST detected most (21 of 24) cataloged earthquakes and 68 uncataloged earthquakes in 1 week of continuous data from a station located near the Calaveras Fault in central California, achieving detection performance comparable to that of autocorrelation, with some additional false detections. FAST is expected to realize its full potential when applied to extremely long duration data sets over a distributed network of seismic stations. The widespread application of FAST has the potential to aid in the discovery of unexpected seismic signals, improve seismic monitoring, and promote a greater understanding of a variety of earthquake processes. PMID:26665176

  4. The utility of focused assessment with sonography for trauma as a triage tool in multiple-casualty incidents during the second Lebanon war.

    PubMed

    Beck-Razi, Nira; Fischer, Doron; Michaelson, Moshe; Engel, Ahuva; Gaitini, Diana

    2007-09-01

    The purpose of this study was to evaluate the role of focused assessment with sonography for trauma (FAST) as a triage tool in multiple-casualty incidents (MCIs) for a single international conflict. The charts of 849 casualties that arrived at our level 1 trauma referral center were reviewed. Casualties were initially triaged according to the Injury Severity Score at the emergency department gate. Two-hundred eighty-one physically injured patients, 215 soldiers (76.5%) and 66 civilians (23.5%), were admitted. Focused assessment with sonography for trauma was performed in 102 casualties suspected to have an abdominal injury. Sixty-eight underwent computed tomography (CT); 12 underwent laparotomy; and 28 were kept under clinical observation alone. We compared FAST results against CT, laparotomy, and clinical observation records. Focused assessment with sonography for trauma results were positive in 17 casualties and negative in 85. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of FAST were 75%, 97.6%, 88.2%, 94.1%, and 93.1%, respectively. A strong correlation between FAST and CT results, laparotomy, and clinical observation was obtained (P < .05). In a setting of a war conflict-related MCI, FAST enabled immediate triage of casualties to laparotomy, CT, or clinical observation. Because of its moderate sensitivity, a negative FAST result with strong clinical suspicion demands further evaluation, especially in an MCI.

  5. Fast support vector data descriptions for novelty detection.

    PubMed

    Liu, Yi-Hung; Liu, Yan-Chen; Chen, Yen-Jen

    2010-08-01

    Support vector data description (SVDD) has become a very attractive kernel method due to its good results in many novelty detection problems. However, the decision function of SVDD is expressed in terms of the kernel expansion, which results in a run-time complexity linear in the number of support vectors. For applications where fast real-time response is needed, how to speed up the decision function is crucial. This paper aims at dealing with the issue of reducing the testing time complexity of SVDD. A method called fast SVDD (F-SVDD) is proposed. Unlike the traditional methods which all try to compress a kernel expansion into one with fewer terms, the proposed F-SVDD directly finds the preimage of a feature vector, and then uses a simple relationship between this feature vector and the SVDD sphere center to re-express the center with a single vector. The decision function of F-SVDD contains only one kernel term, and thus the decision boundary of F-SVDD is only spherical in the original space. Hence, the run-time complexity of the F-SVDD decision function is no longer linear in the support vectors, but is a constant, no matter how large the training set size is. In this paper, we also propose a novel direct preimage-finding method, which is noniterative and involves no free parameters. The unique preimage can be obtained in real time by the proposed direct method without taking trial-and-error. For demonstration, several real-world data sets and a large-scale data set, the extended MIT face data set, are used in experiments. In addition, a practical industry example regarding liquid crystal display micro-defect inspection is also used to compare the applicability of SVDD and our proposed F-SVDD when faced with mass data input. The results are very encouraging.

  6. Surrogate waveform models

    NASA Astrophysics Data System (ADS)

    Blackman, Jonathan; Field, Scott; Galley, Chad; Scheel, Mark; Szilagyi, Bela; Tiglio, Manuel

    2015-04-01

    With the advanced detector era just around the corner, there is a strong need for fast and accurate models of gravitational waveforms from compact binary coalescence. Fast surrogate models can be built out of an accurate but slow waveform model with minimal to no loss in accuracy, but may require a large number of evaluations of the underlying model. This may be prohibitively expensive if the underlying is extremely slow, for example if we wish to build a surrogate for numerical relativity. We examine alternate choices to building surrogate models which allow for a more sparse set of input waveforms. Research supported in part by NSERC.

  7. Two-years of In-flight Spectrometer Calibration Results for the Fast Plasma Investigation (FPI) on the Magmetospheric Multiscale (MMS) Mission

    NASA Astrophysics Data System (ADS)

    Schiff, C.; Gershman, D. J.; Avanov, L. A.; Giles, B. L.; Paterson, W. R.; Kriesler, S.; Barrie, A. C.; Rand, D. K.; Gliese, U.; Burch, J.

    2017-12-01

    Scientifically accurate measurements depend on careful calibration of in-flight instrumentation. We review two years of calibration results for the Fast Plasma Investigation (FPI) electron and ion spectrometers over the MMS fleet. We focus on the operating point calibration by which the operating voltage on each of the 64 spectrometers is set to best balance between gain, signal loss, and anode-to-anode cross talk. In addition, we map the calibration and housekeeping telemetry to infer charge extracted evolution from the microchannel plates and, subsequently, the project lifetime of the instrumentation.

  8. Thermographic measurements of high-speed metal cutting

    NASA Astrophysics Data System (ADS)

    Mueller, Bernhard; Renz, Ulrich

    2002-03-01

    Thermographic measurements of a high-speed cutting process have been performed with an infrared camera. To realize images without motion blur the integration times were reduced to a few microseconds. Since the high tool wear influences the measured temperatures a set-up has been realized which enables small cutting lengths. Only single images have been recorded because the process is too fast to acquire a sequence of images even with the frame rate of the very fast infrared camera which has been used. To expose the camera when the rotating tool is in the middle of the camera image an experimental set-up with a light barrier and a digital delay generator with a time resolution of 1 ns has been realized. This enables a very exact triggering of the camera at the desired position of the tool in the image. Since the cutting depth is between 0.1 and 0.2 mm a high spatial resolution was also necessary which was obtained by a special close-up lens allowing a resolution of app. 45 microns. The experimental set-up will be described and infrared images and evaluated temperatures of a titanium alloy and a carbon steel will be presented for cutting speeds up to 42 m/s.

  9. GrowYourIC: A Step Toward a Coherent Model of the Earth's Inner Core Seismic Structure

    NASA Astrophysics Data System (ADS)

    Lasbleis, Marine; Waszek, Lauren; Day, Elizabeth A.

    2017-11-01

    A complex inner core structure has been well established from seismic studies, showing radial and lateral heterogeneities at various length scales. Yet no geodynamic model is able to explain all the features observed. One of the main limits for this is the lack of tools to compare seismic observations and numerical models successfully. We use here a new Python tool called GrowYourIC to compare models of inner core structure. We calculate properties of geodynamic models of the inner core along seismic raypaths, for random or user-specified data sets. We test kinematic models which simulate fast lateral translation, superrotation, and differential growth. We explore first the influence on a real inner core data set, which has a sparse coverage of the inner core boundary. Such a data set is however able to successfully constrain the hemispherical boundaries due to a good sampling of latitudes. Combining translation and rotation could explain some of the features of the boundaries separating the inner core hemispheres. The depth shift of the boundaries, observed by some authors, seems unlikely to be modeled by a fast translation but could be produced by slow translation associated with superrotation.

  10. A Scalable Framework For Segmenting Magnetic Resonance Images

    PubMed Central

    Hore, Prodip; Goldgof, Dmitry B.; Gu, Yuhua; Maudsley, Andrew A.; Darkazanli, Ammar

    2009-01-01

    A fast, accurate and fully automatic method of segmenting magnetic resonance images of the human brain is introduced. The approach scales well allowing fast segmentations of fine resolution images. The approach is based on modifications of the soft clustering algorithm, fuzzy c-means, that enable it to scale to large data sets. Two types of modifications to create incremental versions of fuzzy c-means are discussed. They are much faster when compared to fuzzy c-means for medium to extremely large data sets because they work on successive subsets of the data. They are comparable in quality to application of fuzzy c-means to all of the data. The clustering algorithms coupled with inhomogeneity correction and smoothing are used to create a framework for automatically segmenting magnetic resonance images of the human brain. The framework is applied to a set of normal human brain volumes acquired from different magnetic resonance scanners using different head coils, acquisition parameters and field strengths. Results are compared to those from two widely used magnetic resonance image segmentation programs, Statistical Parametric Mapping and the FMRIB Software Library (FSL). The results are comparable to FSL while providing significant speed-up and better scalability to larger volumes of data. PMID:20046893

  11. Effects of beta-hydroxy-beta-methylbutyrate (HMB) on the expression of ubiquitin ligases, protein synthesis pathways and contractile function in extensor digitorum longus (EDL) of fed and fasting rats.

    PubMed

    Gerlinger-Romero, Frederico; Guimarães-Ferreira, Lucas; Yonamine, Caio Yogi; Salgueiro, Rafael Barrera; Nunes, Maria Tereza

    2018-03-01

    Beta-hydroxy-beta-methylbutyrate (HMB), a leucine metabolite, enhances the gain of skeletal muscle mass by increasing protein synthesis or attenuating protein degradation or both. The aims of this study were to investigate the effect of HMB on molecular factors controlling skeletal muscle protein synthesis and degradation, as well as muscle contractile function, in fed and fasted conditions. Wistar rats were supplied daily with HMB (320 mg/kg body weight diluted in NaCl-0.9%) or vehicle only (control) by gavage for 28 days. After this period, some of the animals were subjected to a 24-h fasting, while others remained in the fed condition. The EDL muscle was then removed, weighed and used to evaluate the genes and proteins involved in protein synthesis (AKT/4E-BP1/S6) and degradation (Fbxo32 and Trim63). A sub-set of rats were used to measure in vivo muscle contractile function. HMB supplementation increased AKT phosphorylation during fasting (three-fold). In the fed condition, no differences were detected in atrogenes expression between control and HMB supplemented group; however, HMB supplementation did attenuate the fasting-induced increase in their expression levels. Fasting animals receiving HMB showed improved sustained tetanic contraction times (one-fold) and an increased muscle to tibia length ratio (1.3-fold), without any cross-sectional area changes. These results suggest that HMB supplementation under fasting conditions increases AKT phosphorylation and attenuates the increased of atrogenes expression, followed by a functional improvement and gain of skeletal muscle weight, suggesting that HMB protects skeletal muscle against the deleterious effects of fasting.

  12. Predictive value of focused assessment with sonography for trauma (FAST) for laparotomy in unstable polytrauma Egyptians patients.

    PubMed

    Elbaih, Adel Hamed; Abu-Elela, Sameh T

    2017-12-01

    The emergency physicians face significant clinical uncertainty when multiple trauma patients arrive in the emergency department (ED). The priorities for assessment and treatment of polytrauma patients are established in the primary survey. Focused assessment with sonography for trauma (FAST) is very essential clinical skill during trauma resuscitation. Use of point of care ultrasound among the trauma team working in the primary survey in emergency care settings is lacking in Suez Canal University Hospitals even ultrasound machine not available in ED. This study aims to evaluate the accuracy of FAST in hemodynamically unstable polytraumatized patients and to determine its role as an indication of laparotomy. This study is a cross-sectional study included 150 polytrauma patients with a blunt mechanism admitted in Suez Canal University Hospital. Firstly primary survey by airway check, cervical spine securing with neck collar, maintenance of breathing/circulation and management of life threading conditions if present were conducted accordingly to ATLS (advanced trauma life support) guidelines. The patients were assessed in the primary survey using the FAST as a tool to determine the presence of intra-abdominal collection. A total of 150 patients, and FAST scans were performed in all cases. The sensitivity and specificity were 92.6% and 100%, respectively. The negative predictive value was 92%, while the positive predictive value of FAST was 100%. The accuracy of FAST was 96%. FAST is an important method to detect intra-abdominal fluid in the initial assessment in hemodynamically unstable polytrauma patients with high accuracy. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  13. Tele-ultrasound and paramedics: real-time remote physician guidance of the Focused Assessment With Sonography for Trauma examination.

    PubMed

    Boniface, Keith S; Shokoohi, Hamid; Smith, E Reed; Scantlebury, Kari

    2011-06-01

    The aim of this study was to examine the capability of ultrasound-naïve paramedics to obtain interpretable Focused Assessment With Sonography for Trauma (FAST) images under the remote direction of emergency physicians (EPs). Paramedics without experience using ultrasound participated in a 20-minute lecture covering orientation to the ultrasound machine and the FAST examination. The paramedics subsequently performed FAST examinations on a model patient, whereas the EP remained in another room, out of visual contact. The EP communicated with the paramedic via radio, viewing video from the ultrasound machine on a monitor and directing the probe movements to obtain the views of the FAST examination. We examined the success rate, time to complete the examinations, and adequacy of images from the paramedics' first FAST examination. Fifty-one paramedics performed their first FAST examinations and were able to successfully complete 100% of the views of the FAST. The median time from probe placement to examination completion was 262 seconds (interquartile range, 206-343 seconds). The median time to complete right upper quadrant (RUQ) versus left upper quadrant (LUQ) views was 39 and 50 seconds, respectively. The time to complete the LUQ scan took significantly longer than the RUQ (P < .01). Paramedics completed cardiac and pelvic view in a median time of 42 and 25 seconds, respectively. The study demonstrated that paramedics with no prior ultrasound experience could obtain FAST images under remote guidance from experienced EPs in less than 5 minutes. Given rapidly evolving data transmission technology, this has applicability in battlefield, remote, and rural prehospital settings. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. FAST TRACK COMMUNICATION: Uniqueness of static black holes without analyticity

    NASA Astrophysics Data System (ADS)

    Chruściel, Piotr T.; Galloway, Gregory J.

    2010-08-01

    We show that the hypothesis of analyticity in the uniqueness theory of vacuum, or electrovacuum, static black holes is not needed. More generally, we show that prehorizons covering a closed set cannot occur in well-behaved domains of outer communications.

  15. DESIGN OF BIODEGRADATION EXPERIMENTS FOR FLUOROTELOMER-BASED POLYMERS

    EPA Science Inventory

    Fluorotelomer-based polymers (FBPs) are used in a wide variety of consumer products and are widely distributed throughout society. Accordingly, there is great interest in whether and how fast these materials might degrade in various environmental settings. A useful quality of FB...

  16. 35. INTERIOR VIEW OF THE GUARD LOCKS LOCK HOUSE: CLOSED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    35. INTERIOR VIEW OF THE GUARD LOCKS LOCK HOUSE: CLOSED LOCK GATES AND TWO SETS OF MACHINERY TO ASSIST IN OPERATING THEM. VIEW FROM THE FAST END OF THE BUILDING LOOKING WEST 1976 - Pawtucket Canal, Guard Locks, Lowell, Middlesex County, MA

  17. Radio-frequency reflectometry on an undoped AlGaAs/GaAs single electron transistor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacLeod, S. J.; See, A. M.; Keane, Z. K.

    2014-01-06

    Radio frequency reflectometry is demonstrated in a sub-micron undoped AlGaAs/GaAs device. Undoped single electron transistors (SETs) are attractive candidates to study single electron phenomena, due to their charge stability and robust electronic properties after thermal cycling. However, these devices require a large top-gate, which is unsuitable for the fast and sensitive radio frequency reflectometry technique. Here, we demonstrate that rf reflectometry is possible in an undoped SET.

  18. A wideband fast multipole boundary element method for half-space/plane-symmetric acoustic wave problems

    NASA Astrophysics Data System (ADS)

    Zheng, Chang-Jun; Chen, Hai-Bo; Chen, Lei-Lei

    2013-04-01

    This paper presents a novel wideband fast multipole boundary element approach to 3D half-space/plane-symmetric acoustic wave problems. The half-space fundamental solution is employed in the boundary integral equations so that the tree structure required in the fast multipole algorithm is constructed for the boundary elements in the real domain only. Moreover, a set of symmetric relations between the multipole expansion coefficients of the real and image domains are derived, and the half-space fundamental solution is modified for the purpose of applying such relations to avoid calculating, translating and saving the multipole/local expansion coefficients of the image domain. The wideband adaptive multilevel fast multipole algorithm associated with the iterative solver GMRES is employed so that the present method is accurate and efficient for both lowand high-frequency acoustic wave problems. As for exterior acoustic problems, the Burton-Miller method is adopted to tackle the fictitious eigenfrequency problem involved in the conventional boundary integral equation method. Details on the implementation of the present method are described, and numerical examples are given to demonstrate its accuracy and efficiency.

  19. Novel design strategy for checkpoint kinase 2 inhibitors using pharmacophore modeling, combinatorial fusion, and virtual screening.

    PubMed

    Lin, Chun-Yuan; Wang, Yen-Ling

    2014-01-01

    Checkpoint kinase 2 (Chk2) has a great effect on DNA-damage and plays an important role in response to DNA double-strand breaks and related lesions. In this study, we will concentrate on Chk2 and the purpose is to find the potential inhibitors by the pharmacophore hypotheses (PhModels), combinatorial fusion, and virtual screening techniques. Applying combinatorial fusion into PhModels and virtual screening techniques is a novel design strategy for drug design. We used combinatorial fusion to analyze the prediction results and then obtained the best correlation coefficient of the testing set (r test) with the value 0.816 by combining the Best(train)Best(test) and Fast(train)Fast(test) prediction results. The potential inhibitors were selected from NCI database by screening according to Best(train)Best(test) + Fast(train)Fast(test) prediction results and molecular docking with CDOCKER docking program. Finally, the selected compounds have high interaction energy between a ligand and a receptor. Through these approaches, 23 potential inhibitors for Chk2 are retrieved for further study.

  20. Fast and precise thermoregulation system in physiological brain slice experiment

    NASA Astrophysics Data System (ADS)

    Sheu, Y. H.; Young, M. S.

    1995-12-01

    We have developed a fast and precise thermoregulation system incorporated within a physiological experiment on a brain slice. The thermoregulation system is used to control the temperature of a recording chamber in which the brain slice is placed. It consists of a single-chip microcomputer, a set command module, a display module, and an FLC module. A fuzzy control algorithm was developed and a fuzzy logic controller then designed for achieving fast, smooth thermostatic performance and providing precise temperature control with accuracy to 0.1 °C, from room temperature through 42 °C (experimental temperature range). The fuzzy logic controller is implemented by microcomputer software and related peripheral hardware circuits. Six operating modes of thermoregulation are offered with the system and this can be further extended according to experimental needs. The test results of this study demonstrate that the fuzzy control method is easily implemented by a microcomputer and also verifies that this method provides a simple way to achieve fast and precise high-performance control of a nonlinear thermoregulation system in a physiological brain slice experiment.

  1. Fast, Parallel and Secure Cryptography Algorithm Using Lorenz's Attractor

    NASA Astrophysics Data System (ADS)

    Marco, Anderson Gonçalves; Martinez, Alexandre Souto; Bruno, Odemir Martinez

    A novel cryptography method based on the Lorenz's attractor chaotic system is presented. The proposed algorithm is secure and fast, making it practical for general use. We introduce the chaotic operation mode, which provides an interaction among the password, message and a chaotic system. It ensures that the algorithm yields a secure codification, even if the nature of the chaotic system is known. The algorithm has been implemented in two versions: one sequential and slow and the other, parallel and fast. Our algorithm assures the integrity of the ciphertext (we know if it has been altered, which is not assured by traditional algorithms) and consequently its authenticity. Numerical experiments are presented, discussed and show the behavior of the method in terms of security and performance. The fast version of the algorithm has a performance comparable to AES, a popular cryptography program used commercially nowadays, but it is more secure, which makes it immediately suitable for general purpose cryptography applications. An internet page has been set up, which enables the readers to test the algorithm and also to try to break into the cipher.

  2. FAST in Space: Considerations for a Multibeam, Multipurpose Survey Using China's 500-m Aperture Spherical Radio Telescope (FAST)

    NASA Astrophysics Data System (ADS)

    Li, Di; Wang, Pei; Qian, Lei; Krco, Marko; Jiang, Peng; Yue, Youling; Jin, Chenjin; Zhu, Yan; Pan, Zhichen; Nan, Rendong; Dunning, Alex

    2018-04-01

    Having achieved "first light" immediately prior to the ceremony introducing it on 25 September 2016, China's 500-m aperture spherical radio telescope (FAST) is now being kept busy with commissions. Its innovative design requires 1,000 points to be measured and driven instead of just the two axes of motion, e.g., azimuth and elevation for most conventional antennas, to realize pointing and tracking. We have devised a survey plan to exploit the full sensitivity of FAST, while minimizing the complexities involved during system operation. The 19-beam L-band focal plan array will be rotated to specific angles and receive continuous data streams, while the surface shape and the focal cabin stay fixed. Such a survey will cover the northern sky in about 220 full days. Our aim is to obtain data simultaneously for pulsar search, detection of neutral hydrogen (HI) galaxies, HI imaging, and radio transients through multiple back ends. These data sets could represent a significant contribution to all related fields in radio astronomy and remain relevant for decades.

  3. Effect of ultrasound application during setting on the mechanical properties of high viscous glass-ionomers used for ART restorations.

    PubMed

    Daifalla, Lamia E; Mobarak, Enas H

    2015-11-01

    This study was conducted to evaluate the effect of ultrasound application on the surface microhardness (VHN) and diametral tensile strength (DTS) of three high viscous glass-ionomer restorative materials (HVGIRMs). For each test (VHN and DTS), a total of 180 specimens were prepared from three HVGIRMs (Ketac-Molar Aplicap, Fuji IX GP Fast, and ChemFil Rock). Specimens of each material (n = 60) were further subdivided into three subgroups (n = 20) according to the setting modality whether ultrasound (20 or 40 s) was applied during setting or not (control). Specimens within each subgroup were then equally divided (n = 10) and tested at 24 h or 28 days. For the VHN measurement, five indentations, with a 200 g load and a dwell time for 20 s, were made on the top surface of each specimen. The DTS test was done using Lloyd Testing machine at a cross-head speed of 0.5 mm/min. Ultrasound application had no significant effect on the VHN. Fuji IX GP Fast revealed the highest VHN value, followed by Ketac-Molar Aplicap, and the least was recorded for ChemFil Rock. Fuji IX GP Fast and Ketac-Molar Aplicap VHN values were significantly increased by time. ChemFil Rock recorded the highest DTS value at 24 h and was the only material that showed significant improvement with both US application times. However, this improvement did not sustain till 28 days. The ultrasound did not enhance the surface microhardness, but its positive effect on the diametral tensile strength values was material and time dependent.

  4. Effect of ultrasound application during setting on the mechanical properties of high viscous glass-ionomers used for ART restorations

    PubMed Central

    Daifalla, Lamia E.; Mobarak, Enas H.

    2014-01-01

    This study was conducted to evaluate the effect of ultrasound application on the surface microhardness (VHN) and diametral tensile strength (DTS) of three high viscous glass-ionomer restorative materials (HVGIRMs). For each test (VHN and DTS), a total of 180 specimens were prepared from three HVGIRMs (Ketac-Molar Aplicap, Fuji IX GP Fast, and ChemFil Rock). Specimens of each material (n = 60) were further subdivided into three subgroups (n = 20) according to the setting modality whether ultrasound (20 or 40 s) was applied during setting or not (control). Specimens within each subgroup were then equally divided (n = 10) and tested at 24 h or 28 days. For the VHN measurement, five indentations, with a 200 g load and a dwell time for 20 s, were made on the top surface of each specimen. The DTS test was done using Lloyd Testing machine at a cross-head speed of 0.5 mm/min. Ultrasound application had no significant effect on the VHN. Fuji IX GP Fast revealed the highest VHN value, followed by Ketac-Molar Aplicap, and the least was recorded for ChemFil Rock. Fuji IX GP Fast and Ketac-Molar Aplicap VHN values were significantly increased by time. ChemFil Rock recorded the highest DTS value at 24 h and was the only material that showed significant improvement with both US application times. However, this improvement did not sustain till 28 days. The ultrasound did not enhance the surface microhardness, but its positive effect on the diametral tensile strength values was material and time dependent. PMID:26644916

  5. A Predictive Metabolic Signature for the Transition From Gestational Diabetes Mellitus to Type 2 Diabetes.

    PubMed

    Allalou, Amina; Nalla, Amarnadh; Prentice, Kacey J; Liu, Ying; Zhang, Ming; Dai, Feihan F; Ning, Xian; Osborne, Lucy R; Cox, Brian J; Gunderson, Erica P; Wheeler, Michael B

    2016-09-01

    Gestational diabetes mellitus (GDM) affects 3-14% of pregnancies, with 20-50% of these women progressing to type 2 diabetes (T2D) within 5 years. This study sought to develop a metabolomics signature to predict the transition from GDM to T2D. A prospective cohort of 1,035 women with GDM pregnancy were enrolled at 6-9 weeks postpartum (baseline) and were screened for T2D annually for 2 years. Of 1,010 women without T2D at baseline, 113 progressed to T2D within 2 years. T2D developed in another 17 women between 2 and 4 years. A nested case-control design used 122 incident case patients matched to non-case patients by age, prepregnancy BMI, and race/ethnicity. We conducted metabolomics with baseline fasting plasma and identified 21 metabolites that significantly differed by incident T2D status. Machine learning optimization resulted in a decision tree modeling that predicted T2D incidence with a discriminative power of 83.0% in the training set and 76.9% in an independent testing set, which is far superior to measuring fasting plasma glucose levels alone. The American Diabetes Association recommends T2D screening in the early postpartum period via oral glucose tolerance testing after GDM, which is a time-consuming and inconvenient procedure. Our metabolomics signature predicted T2D incidence from a single fasting blood sample. This study represents the first metabolomics study of the transition from GDM to T2D validated in an independent testing set, facilitating early interventions. © 2016 by the American Diabetes Association.

  6. Predicting functional decline and survival in amyotrophic lateral sclerosis.

    PubMed

    Ong, Mei-Lyn; Tan, Pei Fang; Holbrook, Joanna D

    2017-01-01

    Better predictors of amyotrophic lateral sclerosis disease course could enable smaller and more targeted clinical trials. Partially to address this aim, the Prize for Life foundation collected de-identified records from amyotrophic lateral sclerosis sufferers who participated in clinical trials of investigational drugs and made them available to researchers in the PRO-ACT database. In this study, time series data from PRO-ACT subjects were fitted to exponential models. Binary classes for decline in the total score of amyotrophic lateral sclerosis functional rating scale revised (ALSFRS-R) (fast/slow progression) and survival (high/low death risk) were derived. Data was segregated into training and test sets via cross validation. Learning algorithms were applied to the demographic, clinical and laboratory parameters in the training set to predict ALSFRS-R decline and the derived fast/slow progression and high/low death risk categories. The performance of predictive models was assessed by cross-validation in the test set using Receiver Operator Curves and root mean squared errors. A model created using a boosting algorithm containing the decline in four parameters (weight, alkaline phosphatase, albumin and creatine kinase) post baseline, was able to predict functional decline class (fast or slow) with fair accuracy (AUC = 0.82). However similar approaches to build a predictive model for decline class by baseline subject characteristics were not successful. In contrast, baseline values of total bilirubin, gamma glutamyltransferase, urine specific gravity and ALSFRS-R item score-climbing stairs were sufficient to predict survival class. Using combinations of small numbers of variables it was possible to predict classes of functional decline and survival across the 1-2 year timeframe available in PRO-ACT. These findings may have utility for design of future ALS clinical trials.

  7. A Predictive Metabolic Signature for the Transition From Gestational Diabetes Mellitus to Type 2 Diabetes

    PubMed Central

    Allalou, Amina; Nalla, Amarnadh; Prentice, Kacey J.; Liu, Ying; Zhang, Ming; Dai, Feihan F.; Ning, Xian; Osborne, Lucy R.; Cox, Brian J.

    2016-01-01

    Gestational diabetes mellitus (GDM) affects 3–14% of pregnancies, with 20–50% of these women progressing to type 2 diabetes (T2D) within 5 years. This study sought to develop a metabolomics signature to predict the transition from GDM to T2D. A prospective cohort of 1,035 women with GDM pregnancy were enrolled at 6–9 weeks postpartum (baseline) and were screened for T2D annually for 2 years. Of 1,010 women without T2D at baseline, 113 progressed to T2D within 2 years. T2D developed in another 17 women between 2 and 4 years. A nested case-control design used 122 incident case patients matched to non–case patients by age, prepregnancy BMI, and race/ethnicity. We conducted metabolomics with baseline fasting plasma and identified 21 metabolites that significantly differed by incident T2D status. Machine learning optimization resulted in a decision tree modeling that predicted T2D incidence with a discriminative power of 83.0% in the training set and 76.9% in an independent testing set, which is far superior to measuring fasting plasma glucose levels alone. The American Diabetes Association recommends T2D screening in the early postpartum period via oral glucose tolerance testing after GDM, which is a time-consuming and inconvenient procedure. Our metabolomics signature predicted T2D incidence from a single fasting blood sample. This study represents the first metabolomics study of the transition from GDM to T2D validated in an independent testing set, facilitating early interventions. PMID:27338739

  8. Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials.

    PubMed

    Rudolph, Heike; Quaas, Sebastian; Haim, Manuela; Preißler, Jörg; Walter, Michael H; Koch, Rainer; Luthardt, Ralph G

    2013-06-01

    The use of fast-setting impression materials with different viscosities for the one-stage impression technique demands precise working times when mixing. We examined the effect of varying working time on impression precision in a randomized clinical trial. Focusing on tooth 46, three impressions were made from each of 96 volunteers, using either a polyether (PE: Impregum Penta H/L DuoSoft Quick, 3 M ESPE) or an addition-curing silicone (AS: Aquasil Ultra LV, Dentsply/DeTrey), one with the manufacturer's recommended working time (used as a reference) and two with altered working times. All stages of the impression-taking were subject to randomization. The three-dimensional precision of the non-standard working time impressions was digitally analyzed compared to the reference impression. Statistical analysis was performed using multivariate models. The mean difference in the position of the lower right first molar (vs. the reference impression) ranged from ±12 μm for PE to +19 and -14 μm for AS. Significantly higher mean values (+62 to -40 μm) were found for AS compared to PE (+21 to -26 μm) in the area of the distal adjacent tooth. Fast-set impression materials offer high precision when used for single tooth restorations as part of a one-stage impression technique, even when the working time (mixing plus application of the light- and heavy-body components) diverges significantly from the manufacturer's recommended protocol. Best accuracy was achieved with machine-mixed heavy-body/light-body polyether. Both materials examined met the clinical requirements regarding precision when the teeth were completely syringed with light material.

  9. Evidence Supporting a Role for Constitutive Ghrelin Receptor Signaling in Fasting-Induced Hyperphagia in Male Mice.

    PubMed

    Fernandez, Gimena; Cabral, Agustina; Andreoli, María F; Labarthe, Alexandra; M'Kadmi, Céline; Ramos, Jorge G; Marie, Jacky; Fehrentz, Jean-Alain; Epelbaum, Jacques; Tolle, Virginie; Perello, Mario

    2018-02-01

    Ghrelin is a potent orexigenic peptide hormone that acts through the growth hormone secretagogue receptor (GHSR), a G protein-coupled receptor highly expressed in the hypothalamus. In vitro studies have shown that GHSR displays a high constitutive activity, whose physiological relevance is uncertain. As GHSR gene expression in the hypothalamus is known to increase in fasting conditions, we tested the hypothesis that constitutive GHSR activity at the hypothalamic level drives the fasting-induced hyperphagia. We found that refed wild-type (WT) mice displayed a robust hyperphagia that continued for 5 days after refeeding and changed their food intake daily pattern. Fasted WT mice showed an increase in plasma ghrelin levels, as well as in GHSR expression levels and ghrelin binding sites in the hypothalamic arcuate nucleus. When fasting-refeeding responses were evaluated in ghrelin- or GHSR-deficient mice, only the latter displayed an ∼15% smaller hyperphagia, compared with WT mice. Finally, fasting-induced hyperphagia of WT mice was significantly smaller in mice centrally treated with the GHSR inverse agonist K-(D-1-Nal)-FwLL-NH2, compared with mice treated with vehicle, whereas it was unaffected in mice centrally treated with the GHSR antagonists D-Lys3-growth hormone-releasing peptide 6 or JMV2959. Taken together, genetic models and pharmacological results support the notion that constitutive GHSR activity modulates the magnitude of the compensatory hyperphagia triggered by fasting. Thus, the hypothalamic GHSR signaling system could affect the set point of daily food intake, independently of plasma ghrelin levels, in situations of negative energy balance. Copyright © 2018 Endocrine Society.

  10. Restoring integrity—A grounded theory of coping with a fast track surgery programme

    PubMed Central

    Jørgensen, Lene Bastrup; Fridlund, Bengt

    2016-01-01

    Aims and objectives The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Background Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. Design The study design used classical grounded theory. Methods The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Results Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients’ main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. Conclusion In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme. PMID:26751199

  11. Associations between major chain fast-food outlet availability and change in body mass index: a longitudinal observational study of women from Victoria, Australia

    PubMed Central

    Thornton, Lukar E; Olstad, Dana Lee; Cerin, Ester; Ball, Kylie

    2017-01-01

    Objectives The residential neighbourhood fast-food environment has the potential to lead to increased levels of obesity by providing opportunities for residents to consume energy-dense products. This longitudinal study aimed to examine whether change in body mass index (BMI) differed dependent on major chain fast-food outlet availability among women residing in disadvantaged neighbourhoods. Setting Eighty disadvantaged neighbourhoods in Victoria, Australia. Participants Sample of 882 women aged 18–46 years at baseline (wave I: 2007/2008) who remained at the same residential location at all three waves (wave II: 2010/2011; wave III: 2012/2013) of the Resilience for Eating and Activity Despite Inequality study. Primary outcome BMI based on self-reported height and weight at each wave. Results There was no evidence of an interaction between time and the number of major chain fast-food outlets within 2 (p=0.88), 3 (p=0.66) or 5 km (p=0.24) in the multilevel models of BMI. Furthermore, there was no evidence of an interaction between time and change in availability at any distance and BMI. Conclusions Change in BMI was not found to differ by residential major chain fast-food outlet availability among Victorian women residing in disadvantaged neighbourhoods. It may be that exposure to fast-food outlets around other locations regularly visited influence change in BMI. Future research needs to consider what environments are the key sources for accessing and consuming fast food and how these relate to BMI and obesity risk. PMID:29042381

  12. Obesity and the Built Environment: Does the Density of Neighborhood Fast-Food Outlets Matter?

    PubMed Central

    Li, Fuzhong; Harmer, Peter; Cardinal, Bradley J.; Bosworth, Mark; Johnson-Shelton, Deb

    2009-01-01

    Purpose To examine variation in obesity among older adults relative to the joint influences of density of neighborhood fast-food outlets and residents' behavioral, psychosocial, and sociodemographic characteristics. Design Cross-sectional and multilevel design. Setting Census block groups, used as a proxy for neighborhoods, within the metropolitan region's Urban Growth Boundary in Portland, Oregon. Subjects A total of 1,221 residents (mean age=65 years old) recruited randomly from 120 neighborhoods (48% response rate). Measures A Geographic Information System-based measure of fast-food restaurant density across 120 neighborhoods was created. Residents within the sampled neighborhoods were assessed with respect to their body mass index (BMI), frequency of visits to local fast-food restaurants, fried food consumption, levels of physical activity, self-efficacy of eating fruits and vegetables, household income, and race/ethnicity. Analyses Multilevel logistic regression analyses. Results Significant associations were found between resident-level individual characteristics and the likelihood of being obese (BMI≥30) for neighborhoods with a high-density of fast-food restaurants in comparison to those with a low density: odds ratios [OR] for obesity, 95% confidence interval [CI] were: 1.878 (CI=1.006-3.496) for weekly visits to local fast-food restaurants; 1.792 (CI=1.006-3.190) for not meeting physical activity recommendations; 1.212 (CI=1.057-1.391) for low confidence in eating healthy food; and 8.057 (CI=1.705-38.086) for non-Hispanic black residents. Conclusion Increased density of neighborhood fast-food outlets was associated with unhealthy lifestyles, poorer psychosocial profiles, and increased risk of obesity among older adults. PMID:19149426

  13. Ramadan fasting in patients with adrenal insufficiency.

    PubMed

    Chihaoui, Mélika; Chaker, Fatma; Yazidi, Meriem; Grira, Wafa; Ben Amor, Zohra; Rejeb, Ons; Slimane, Hedia

    2017-01-01

    The risks of fasting during Ramadan in patients with adrenal insufficiency are unknown. The aims of this study were to evaluate these risks in such patients, to determine the risk factors and finally to set some recommendations. It is a cross-sectional study about 180 patients with known and treated adrenal insufficiency. The patients responded to a 14-item questionnaire concerning their knowledge about the disease and fasting during the last month of Ramadan. There were 132 women and 48 men. The mean age was 47.6 ± 15.0 years (14-79). One hundred and thirty eight patients (76.7 %) were advised by their physician not to fast. Ninety-one patients (50.5 %) tried to fast. Complications occurred in 61 cases (67.0 %): asthenia in 88.5 % of cases, intense thirst in 32.8 %, symptoms of dehydration in 49.2 % and symptoms of hypoglycaemia in 18 %. One patient was hospitalized. Fifty-five patients (60.4 %) were able to fast for the whole month. Age, gender, duration of the disease, its primary origin, associated hypothyroidism, diabetes mellitus, hypertension or diabetes insipidus and daily dose of hydrocortisone did not significantly differ between fasters and non-fasters, full-month-fasters and partial-month-fasters, and fasters with complications and fasters without complications. The frequency of adequate knowledge about the disease was significantly higher in full-month-fasters vs. partial-month-fasters, and in fasters without complications vs. those with complications. In patients with adrenal insufficiency, fasting can cause complications especially if the level of knowledge about the disease is low.

  14. Vocabulary Learning in a Yorkshire Terrier: Slow Mapping of Spoken Words

    PubMed Central

    Griebel, Ulrike; Oller, D. Kimbrough

    2012-01-01

    Rapid vocabulary learning in children has been attributed to “fast mapping”, with new words often claimed to be learned through a single presentation. As reported in 2004 in Science a border collie (Rico) not only learned to identify more than 200 words, but fast mapped the new words, remembering meanings after just one presentation. Our research tests the fast mapping interpretation of the Science paper based on Rico's results, while extending the demonstration of large vocabulary recognition to a lap dog. We tested a Yorkshire terrier (Bailey) with the same procedures as Rico, illustrating that Bailey accurately retrieved randomly selected toys from a set of 117 on voice command of the owner. Second we tested her retrieval based on two additional voices, one male, one female, with different accents that had never been involved in her training, again showing she was capable of recognition by voice command. Third, we did both exclusion-based training of new items (toys she had never seen before with names she had never heard before) embedded in a set of known items, with subsequent retention tests designed as in the Rico experiment. After Bailey succeeded on exclusion and retention tests, a crucial evaluation of true mapping tested items previously successfully retrieved in exclusion and retention, but now pitted against each other in a two-choice task. Bailey failed on the true mapping task repeatedly, illustrating that the claim of fast mapping in Rico had not been proven, because no true mapping task had ever been conducted with him. It appears that the task called retention in the Rico study only demonstrated success in retrieval by a process of extended exclusion. PMID:22363421

  15. Price, promotion, and availability of nutrition information: a descriptive study of a popular fast food chain in New York City.

    PubMed

    Basch, Corey Hannah; Ethan, Danna; Rajan, Sonali

    2013-08-25

    Legislation in NYC requires chain restaurants to post calorie information on menu boards in an effort to help consumers make more informed decisions about food and beverage items they are purchasing. While this is a step in the right direction in light of the current obesity epidemic, there are other issues that warrant attention in a fast food setting, namely the pricing of healthy food options, promotional strategies, and access to comprehensive nutrition information. This study focused on a popular fast-food chain in NYC. The study's aims were threefold: (1) to determine the cost differential between the healthiest meal item on the chain's general menu and meal items available specifically on a reduced cost menu for one dollar (US$1.00); (2) to identify and describe the promotions advertised in the windows of these restaurants, as well as the nutrition content of promoted items; and (3) to ascertain availability of comprehensive nutrition information to consumers within the restaurants. We found the healthiest meal item to be significantly higher in price than less nutritious meal items available for $1.00 (t=146.9, p<.001), with the mean cost differential equal to $4.33 (95% CI: $4.27, $4.39). Window promotions generally advertised less healthful menu items, which may aid in priming customers to purchase these versus more healthful options. Comprehensive nutrition information beyond calorie counts was not readily accessible prior to purchasing. In addition to improving access to comprehensive nutrition information, advertising more of and lowering the prices of nutritious options may encourage consumers to purchase healthier foods in a fast food setting. Additional research in this area is needed in other geographic locations and restaurant chains. 

  16. Cognitive Processing Speed, Working Memory, and the Intelligibility of Hearing Aid-Processed Speech in Persons with Hearing Impairment

    PubMed Central

    Yumba, Wycliffe Kabaywe

    2017-01-01

    Previous studies have demonstrated that successful listening with advanced signal processing in digital hearing aids is associated with individual cognitive capacity, particularly working memory capacity (WMC). This study aimed to examine the relationship between cognitive abilities (cognitive processing speed and WMC) and individual listeners’ responses to digital signal processing settings in adverse listening conditions. A total of 194 native Swedish speakers (83 women and 111 men), aged 33–80 years (mean = 60.75 years, SD = 8.89), with bilateral, symmetrical mild to moderate sensorineural hearing loss who had completed a lexical decision speed test (measuring cognitive processing speed) and semantic word-pair span test (SWPST, capturing WMC) participated in this study. The Hagerman test (capturing speech recognition in noise) was conducted using an experimental hearing aid with three digital signal processing settings: (1) linear amplification without noise reduction (NoP), (2) linear amplification with noise reduction (NR), and (3) non-linear amplification without NR (“fast-acting compression”). The results showed that cognitive processing speed was a better predictor of speech intelligibility in noise, regardless of the types of signal processing algorithms used. That is, there was a stronger association between cognitive processing speed and NR outcomes and fast-acting compression outcomes (in steady state noise). We observed a weaker relationship between working memory and NR, but WMC did not relate to fast-acting compression. WMC was a relatively weaker predictor of speech intelligibility in noise. These findings might have been different if the participants had been provided with training and or allowed to acclimatize to binary masking noise reduction or fast-acting compression. PMID:28861009

  17. Price, Promotion, and Availability of Nutrition Information: A Descriptive Study of a Popular Fast Food Chain in New York City

    PubMed Central

    Basch, Corey Hannah; Ethan, Danna; Rajan, Sonali

    2013-01-01

    Legislation in NYC requires chain restaurants to post calorie information on menu boards in an effort to help consumers make more informed decisions about food and beverage items they are purchasing. While this is a step in the right direction in light of the current obesity epidemic, there are other issues that warrant attention in a fast food setting, namely the pricing of healthy food options, promotional strategies, and access to comprehensive nutrition information. This study focused on a popular fast-food chain in NYC. The study’s aims were threefold: (1) to determine the cost differential between the healthiest meal item on the chain’s general menu and meal items available specifically on a reduced cost menu for one dollar (US$1.00); (2) to identify and describe the promotions advertised in the windows of these restaurants, as well as the nutrition content of promoted items; and (3) to ascertain availability of comprehensive nutrition information to consumers within the restaurants. We found the healthiest meal item to be significantly higher in price than less nutritious meal items available for $1.00 (t = 146.9, p < .001), with the mean cost differential equal to $4.33 (95% CI $4.27, $4.39). Window promotions generally advertised less healthful menu items, which may aid in priming customers to purchase these versus more healthful options. Comprehensive nutrition information beyond calorie counts was not readily accessible prior to purchasing. In addition to improving access to comprehensive nutrition information, advertising more of and lowering the prices of nutritious options may encourage consumers to purchase healthier foods in a fast food setting. Additional research in this area is needed in other geographic locations and restaurant chains. PMID:24171876

  18. FastScript3D - A Companion to Java 3D

    NASA Technical Reports Server (NTRS)

    Koenig, Patti

    2005-01-01

    FastScript3D is a computer program, written in the Java 3D(TM) programming language, that establishes an alternative language that helps users who lack expertise in Java 3D to use Java 3D for constructing three-dimensional (3D)-appearing graphics. The FastScript3D language provides a set of simple, intuitive, one-line text-string commands for creating, controlling, and animating 3D models. The first word in a string is the name of a command; the rest of the string contains the data arguments for the command. The commands can also be used as an aid to learning Java 3D. Developers can extend the language by adding custom text-string commands. The commands can define new 3D objects or load representations of 3D objects from files in formats compatible with such other software systems as X3D. The text strings can be easily integrated into other languages. FastScript3D facilitates communication between scripting languages [which enable programming of hyper-text markup language (HTML) documents to interact with users] and Java 3D. The FastScript3D language can be extended and customized on both the scripting side and the Java 3D side.

  19. A FRAMEWORK FOR INTERPRETING FAST RADIO TRANSIENTS SEARCH EXPERIMENTS: APPLICATION TO THE V-FASTR EXPERIMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trott, Cathryn M.; Tingay, Steven J.; Wayth, Randall B.

    2013-04-10

    We define a framework for determining constraints on the detection rate of fast transient events from a population of underlying sources, with a view to incorporate beam shape, frequency effects, scattering effects, and detection efficiency into the metric. We then demonstrate a method for combining independent data sets into a single event rate constraint diagram, using a probabilistic approach to the limits on parameter space. We apply this new framework to present the latest results from the V-FASTR experiment, a commensal fast transients search using the Very Long Baseline Array (VLBA). In the 20 cm band, V-FASTR now has themore » ability to probe the regions of parameter space of importance for the observed Lorimer and Keane fast radio transient candidates by combining the information from observations with differing bandwidths, and properly accounting for the source dispersion measure, VLBA antenna beam shape, experiment time sampling, and stochastic nature of events. We then apply the framework to combine the results of the V-FASTR and Allen Telescope Array Fly's Eye experiments, demonstrating their complementarity. Expectations for fast transients experiments for the SKA Phase I dish array are then computed, and the impact of large differential bandwidths is discussed.« less

  20. Ground reaction force, spinal kinematics and their relationship to lower back pain and injury in cricket fast bowling: A review.

    PubMed

    Senington, Billy; Lee, Raymond Y; Williams, Jonathan Mark

    2018-03-09

    Fast bowlers display a high risk of lower back injury and pain. Studies report factors that may increase this risk, however exact mechanisms remain unclear. To provide a contemporary analysis of literature, up to April 2016, regarding fast bowling, spinal kinematics, ground reaction force (GRF), lower back pain (LBP) and pathology. Key terms including biomechanics, bowling, spine and injury were searched within MEDLINE, Google Scholar, SPORTDiscuss, Science Citation Index, OAIster, CINAHL, Academic Search Complete, Science Direct and Scopus. Following application of inclusion criteria, 56 studies (reduced from 140) were appraised for quality and pooled for further analysis. Twelve times greater risk of lumbar injury was reported in bowlers displaying excessive shoulder counter-rotation (SCR), however SCR is a surrogate measure which may not describe actual spinal movement. Little is known about LBP specifically. Weighted averages of 5.8 ± 1.3 times body weight (BW) vertically and 3.2 ± 1.1 BW horizontally were calculated for peak GRF during fast bowling. No quantitative synthesis of kinematic data was possible due to heterogeneity of reported results. Fast bowling is highly injurious especially with excessive SCR. Studies adopted similar methodologies, constrained to laboratory settings. Future studies should focus on methods to determine biomechanics during live play.

  1. Relating Memory To Functional Performance In Normal Aging to Dementia Using Hierarchical Bayesian Cognitive Processing Models

    PubMed Central

    Shankle, William R.; Pooley, James P.; Steyvers, Mark; Hara, Junko; Mangrola, Tushar; Reisberg, Barry; Lee, Michael D.

    2012-01-01

    Determining how cognition affects functional abilities is important in Alzheimer’s disease and related disorders (ADRD). 280 patients (normal or ADRD) received a total of 1,514 assessments using the Functional Assessment Staging Test (FAST) procedure and the MCI Screen (MCIS). A hierarchical Bayesian cognitive processing (HBCP) model was created by embedding a signal detection theory (SDT) model of the MCIS delayed recognition memory task into a hierarchical Bayesian framework. The SDT model used latent parameters of discriminability (memory process) and response bias (executive function) to predict, simultaneously, recognition memory performance for each patient and each FAST severity group. The observed recognition memory data did not distinguish the six FAST severity stages, but the latent parameters completely separated them. The latent parameters were also used successfully to transform the ordinal FAST measure into a continuous measure reflecting the underlying continuum of functional severity. HBCP models applied to recognition memory data from clinical practice settings accurately translated a latent measure of cognition to a continuous measure of functional severity for both individuals and FAST groups. Such a translation links two levels of brain information processing, and may enable more accurate correlations with other levels, such as those characterized by biomarkers. PMID:22407225

  2. Relating memory to functional performance in normal aging to dementia using hierarchical Bayesian cognitive processing models.

    PubMed

    Shankle, William R; Pooley, James P; Steyvers, Mark; Hara, Junko; Mangrola, Tushar; Reisberg, Barry; Lee, Michael D

    2013-01-01

    Determining how cognition affects functional abilities is important in Alzheimer disease and related disorders. A total of 280 patients (normal or Alzheimer disease and related disorders) received a total of 1514 assessments using the functional assessment staging test (FAST) procedure and the MCI Screen. A hierarchical Bayesian cognitive processing model was created by embedding a signal detection theory model of the MCI Screen-delayed recognition memory task into a hierarchical Bayesian framework. The signal detection theory model used latent parameters of discriminability (memory process) and response bias (executive function) to predict, simultaneously, recognition memory performance for each patient and each FAST severity group. The observed recognition memory data did not distinguish the 6 FAST severity stages, but the latent parameters completely separated them. The latent parameters were also used successfully to transform the ordinal FAST measure into a continuous measure reflecting the underlying continuum of functional severity. Hierarchical Bayesian cognitive processing models applied to recognition memory data from clinical practice settings accurately translated a latent measure of cognition into a continuous measure of functional severity for both individuals and FAST groups. Such a translation links 2 levels of brain information processing and may enable more accurate correlations with other levels, such as those characterized by biomarkers.

  3. mrsFAST-Ultra: a compact, SNP-aware mapper for high performance sequencing applications.

    PubMed

    Hach, Faraz; Sarrafi, Iman; Hormozdiari, Farhad; Alkan, Can; Eichler, Evan E; Sahinalp, S Cenk

    2014-07-01

    High throughput sequencing (HTS) platforms generate unprecedented amounts of data that introduce challenges for processing and downstream analysis. While tools that report the 'best' mapping location of each read provide a fast way to process HTS data, they are not suitable for many types of downstream analysis such as structural variation detection, where it is important to report multiple mapping loci for each read. For this purpose we introduce mrsFAST-Ultra, a fast, cache oblivious, SNP-aware aligner that can handle the multi-mapping of HTS reads very efficiently. mrsFAST-Ultra improves mrsFAST, our first cache oblivious read aligner capable of handling multi-mapping reads, through new and compact index structures that reduce not only the overall memory usage but also the number of CPU operations per alignment. In fact the size of the index generated by mrsFAST-Ultra is 10 times smaller than that of mrsFAST. As importantly, mrsFAST-Ultra introduces new features such as being able to (i) obtain the best mapping loci for each read, and (ii) return all reads that have at most n mapping loci (within an error threshold), together with these loci, for any user specified n. Furthermore, mrsFAST-Ultra is SNP-aware, i.e. it can map reads to reference genome while discounting the mismatches that occur at common SNP locations provided by db-SNP; this significantly increases the number of reads that can be mapped to the reference genome. Notice that all of the above features are implemented within the index structure and are not simple post-processing steps and thus are performed highly efficiently. Finally, mrsFAST-Ultra utilizes multiple available cores and processors and can be tuned for various memory settings. Our results show that mrsFAST-Ultra is roughly five times faster than its predecessor mrsFAST. In comparison to newly enhanced popular tools such as Bowtie2, it is more sensitive (it can report 10 times or more mappings per read) and much faster (six times or more) in the multi-mapping mode. Furthermore, mrsFAST-Ultra has an index size of 2GB for the entire human reference genome, which is roughly half of that of Bowtie2. mrsFAST-Ultra is open source and it can be accessed at http://mrsfast.sourceforge.net. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  4. Fast Multiscale Algorithms for Information Representation and Fusion

    DTIC Science & Technology

    2011-07-01

    We are also developing convenient command-line invocation tools in addition to the previously developed APIs . Various real-world data sets...This knowledge is important in geolocation applications where knowing whether a received signal is line-of-sight or not is necessary for the

  5. Graphene field-effect transistors as room-temperature terahertz detectors.

    PubMed

    Vicarelli, L; Vitiello, M S; Coquillat, D; Lombardo, A; Ferrari, A C; Knap, W; Polini, M; Pellegrini, V; Tredicucci, A

    2012-10-01

    The unique optoelectronic properties of graphene make it an ideal platform for a variety of photonic applications, including fast photodetectors, transparent electrodes in displays and photovoltaic modules, optical modulators, plasmonic devices, microcavities, and ultra-fast lasers. Owing to its high carrier mobility, gapless spectrum and frequency-independent absorption, graphene is a very promising material for the development of detectors and modulators operating in the terahertz region of the electromagnetic spectrum (wavelengths in the hundreds of micrometres), still severely lacking in terms of solid-state devices. Here we demonstrate terahertz detectors based on antenna-coupled graphene field-effect transistors. These exploit the nonlinear response to the oscillating radiation field at the gate electrode, with contributions of thermoelectric and photoconductive origin. We demonstrate room temperature operation at 0.3 THz, showing that our devices can already be used in realistic settings, enabling large-area, fast imaging of macroscopic samples.

  6. Transcription Factor Networks Directing the Development, Function, and Evolution of Innate Lymphoid Effectors

    PubMed Central

    Kang, Joonsoo; Malhotra, Nidhi

    2015-01-01

    Mammalian lymphoid immunity is mediated by fast and slow responders to pathogens. Fast innate lymphocytes are active within hours after infections in mucosal tissues. Slow adaptive lymphocytes are conventional T and B cells with clonal antigen receptors that function days after pathogen exposure. A transcription factor (TF) regulatory network guiding early T cell development is at the core of effector function diversification in all innate lymphocytes, and the kinetics of immune responses is set by developmental programming. Operational units within the innate lymphoid system are not classified by the types of pathogen-sensing machineries but rather by discrete effector functions programmed by regulatory TF networks. Based on the evolutionary history of TFs of the regulatory networks, fast effectors likely arose earlier in the evolution of animals to fortify body barriers, and in mammals they often develop in fetal ontogeny prior to the establishment of fully competent adaptive immunity. PMID:25650177

  7. Rotary fast tool servo system and methods

    DOEpatents

    Montesanti, Richard C.; Trumper, David L.

    2007-10-02

    A high bandwidth rotary fast tool servo provides tool motion in a direction nominally parallel to the surface-normal of a workpiece at the point of contact between the cutting tool and workpiece. Three or more flexure blades having all ends fixed are used to form an axis of rotation for a swing arm that carries a cutting tool at a set radius from the axis of rotation. An actuator rotates a swing arm assembly such that a cutting tool is moved in and away from the lathe-mounted, rotating workpiece in a rapid and controlled manner in order to machine the workpiece. A pair of position sensors provides rotation and position information for a swing arm to a control system. A control system commands and coordinates motion of the fast tool servo with the motion of a spindle, rotating table, cross-feed slide, and in-feed slide of a precision lathe.

  8. Rotary fast tool servo system and methods

    DOEpatents

    Montesanti, Richard C [Cambridge, MA; Trumper, David L [Plaistow, NH; Kirtley, Jr., James L.

    2009-08-18

    A high bandwidth rotary fast tool servo provides tool motion in a direction nominally parallel to the surface-normal of a workpiece at the point of contact between the cutting tool and workpiece. Three or more flexure blades having all ends fixed are used to form an axis of rotation for a swing arm that carries a cutting tool at a set radius from the axis of rotation. An actuator rotates a swing arm assembly such that a cutting tool is moved in and away from the lathe-mounted, rotating workpiece in a rapid and controlled manner in order to machine the workpiece. One or more position sensors provides rotation and position information for a swing arm to a control system. A control system commands and coordinates motion of the fast tool servo with the motion of a spindle, rotating table, cross-feed slide, and in-feed slide of a precision lathe.

  9. Fast stars point to supernovae, black holes

    NASA Astrophysics Data System (ADS)

    Sokol, Joshua

    2018-05-01

    On 25 April, the European Space Agency released a data set gathered by the Gaia satellite containing the motions, and much more, of 1.3 billion stars. Astronomers have immediately sifted the data for fast-moving stars. They are prized as forensic tools: When rewound, their trajectories point back to the violent events that launched them. Last week, one team reported the discovery of three white dwarfs—the dying embers of sunlike stars—hurtling through the galaxy at thousands of kilometers per second, perhaps flung out from supernovae explosions. Another group reported more than two dozen fast-moving stars, some apparently kicked out by our galaxy's central black hole. And a third has confirmed that a star blazing through the outskirts of the Milky Way actually hails from another galaxy altogether, the Large Magellanic Cloud. The flood of discoveries has sent astronomers racing to their telescopes to check and classify the swift objects, says Harvard University astronomer James Guillochon.

  10. The SUrvey for Pulsars and Extragalactic Radio Bursts - I. Survey description and overview

    NASA Astrophysics Data System (ADS)

    Keane, E. F.; Barr, E. D.; Jameson, A.; Morello, V.; Caleb, M.; Bhandari, S.; Petroff, E.; Possenti, A.; Burgay, M.; Tiburzi, C.; Bailes, M.; Bhat, N. D. R.; Burke-Spolaor, S.; Eatough, R. P.; Flynn, C.; Jankowski, F.; Johnston, S.; Kramer, M.; Levin, L.; Ng, C.; van Straten, W.; Krishnan, V. Venkatraman

    2018-01-01

    We describe the Survey for Pulsars and Extragalactic Radio Bursts (SUPERB), an ongoing pulsar and fast transient survey using the Parkes radio telescope. SUPERB involves real-time acceleration searches for pulsars and single-pulse searches for pulsars and fast radio bursts. We report on the observational set-up, data analysis, multiwavelength/messenger connections, survey sensitivities to pulsars and fast radio bursts and the impact of radio frequency interference. We further report on the first 10 pulsars discovered in the project. Among these is PSR J1306-40, a millisecond pulsar in a binary system where it appears to be eclipsed for a large fraction of the orbit. PSR J1421-4407 is another binary millisecond pulsar; its orbital period is 30.7 d. This orbital period is in a range where only highly eccentric binaries are known, and expected by theory; despite this its orbit has an eccentricity of 10-5.

  11. Mild hypercholesterolemia, normal plasma triglycerides, and normal glucose levels across dementia staging in Alzheimer's disease: a clinical setting-based retrospective study.

    PubMed

    Ramdane, Said; Daoudi-Gueddah, Doria

    2011-08-01

    We examined retrospectively the concurrent relationships between fasting plasma total cholesterol, triglycerides, and glucose levels, and Alzheimer's disease (AD), in a clinical setting-based study. Total cholesterol level was higher in patients with AD compared to elderly controls; triglycerides or glucose levels did not significantly differ between the 2 groups. Respective plotted trajectories of change in cholesterol level across age were fairly parallel. No significant difference in total cholesterol levels was recorded between patients with AD classified by the Clinical Dementia Rating (CDR) score subgroups. These results suggest that patients with AD have relative mild total hypercholesterolemia, normal triglyceridemia, and normal fasting plasma glucose level. Mild total hypercholesterolemia seems to be permanent across age, and across dementia severity staging, and fairly parallels the trajectory of age-related change in total cholesterolemia of healthy controls. We speculate that these biochemical parameters pattern may be present long before-a decade at least-the symptomatic onset of the disease.

  12. Definition of a Robust Supervisory Control Scheme for Sodium-Cooled Fast Reactors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ponciroli, R.; Passerini, S.; Vilim, R. B.

    In this work, an innovative control approach for metal-fueled Sodium-cooled Fast Reactors is proposed. With respect to the classical approach adopted for base-load Nuclear Power Plants, an alternative control strategy for operating the reactor at different power levels by respecting the system physical constraints is presented. In order to achieve a higher operational flexibility along with ensuring that the implemented control loops do not influence the system inherent passive safety features, a dedicated supervisory control scheme for the dynamic definition of the corresponding set-points to be supplied to the PID controllers is designed. In particular, the traditional approach based onmore » the adoption of tabulated lookup tables for the set-point definition is found not to be robust enough when failures of the implemented SISO (Single Input Single Output) actuators occur. Therefore, a feedback algorithm based on the Reference Governor approach, which allows for the optimization of reference signals according to the system operating conditions, is proposed.« less

  13. Vision System for Coarsely Estimating Motion Parameters for Unknown Fast Moving Objects in Space

    PubMed Central

    Chen, Min; Hashimoto, Koichi

    2017-01-01

    Motivated by biological interests in analyzing navigation behaviors of flying animals, we attempt to build a system measuring their motion states. To do this, in this paper, we build a vision system to detect unknown fast moving objects within a given space, calculating their motion parameters represented by positions and poses. We proposed a novel method to detect reliable interest points from images of moving objects, which can be hardly detected by general purpose interest point detectors. 3D points reconstructed using these interest points are then grouped and maintained for detected objects, according to a careful schedule, considering appearance and perspective changes. In the estimation step, a method is introduced to adapt the robust estimation procedure used for dense point set to the case for sparse set, reducing the potential risk of greatly biased estimation. Experiments are conducted against real scenes, showing the capability of the system of detecting multiple unknown moving objects and estimating their positions and poses. PMID:29206189

  14. Ga-doped indium oxide nanowire phase change random access memory cells

    NASA Astrophysics Data System (ADS)

    Jin, Bo; Lim, Taekyung; Ju, Sanghyun; Latypov, Marat I.; Kim, Hyoung Seop; Meyyappan, M.; Lee, Jeong-Soo

    2014-02-01

    Phase change random access memory (PCRAM) devices are usually constructed using tellurium based compounds, but efforts to seek other materials providing desirable memory characteristics have continued. We have fabricated PCRAM devices using Ga-doped In2O3 nanowires with three different Ga compositions (Ga/(In+Ga) atomic ratio: 2.1%, 11.5% and 13.0%), and investigated their phase switching properties. The nanowires (˜40 nm in diameter) can be repeatedly switched between crystalline and amorphous phases, and Ga concentration-dependent memory switching behavior in the nanowires was observed with ultra-fast set/reset rates of 80 ns/20 ns, which are faster than for other competitive phase change materials. The observations of fast set/reset rates and two distinct states with a difference in resistance of two to three orders of magnitude appear promising for nonvolatile information storage. Moreover, we found that increasing the Ga concentration can reduce the power consumption and resistance drift; however, too high a level of Ga doping may cause difficulty in achieving the phase transition.

  15. Development of a fast, lean and agile direct pelletization process using experimental design techniques.

    PubMed

    Politis, Stavros N; Rekkas, Dimitrios M

    2017-04-01

    A novel hot melt direct pelletization method was developed, characterized and optimized, using statistical thinking and experimental design tools. Mixtures of carnauba wax (CW) and HPMC K100M were spheronized using melted gelucire 50-13 as a binding material (BM). Experimentation was performed sequentially; a fractional factorial design was set up initially to screen the factors affecting the process, namely spray rate, quantity of BM, rotor speed, type of rotor disk, lubricant-glidant presence, additional spheronization time, powder feeding rate and quantity. From the eight factors assessed, three were further studied during process optimization (spray rate, quantity of BM and powder feeding rate), at different ratios of the solid mixture of CW and HPMC K100M. The study demonstrated that the novel hot melt process is fast, efficient, reproducible and predictable. Therefore, it can be adopted in a lean and agile manufacturing setting for the production of flexible pellet dosage forms with various release rates easily customized between immediate and modified delivery.

  16. Fast Semantic Segmentation of 3d Point Clouds with Strongly Varying Density

    NASA Astrophysics Data System (ADS)

    Hackel, Timo; Wegner, Jan D.; Schindler, Konrad

    2016-06-01

    We describe an effective and efficient method for point-wise semantic classification of 3D point clouds. The method can handle unstructured and inhomogeneous point clouds such as those derived from static terrestrial LiDAR or photogammetric reconstruction; and it is computationally efficient, making it possible to process point clouds with many millions of points in a matter of minutes. The key issue, both to cope with strong variations in point density and to bring down computation time, turns out to be careful handling of neighborhood relations. By choosing appropriate definitions of a point's (multi-scale) neighborhood, we obtain a feature set that is both expressive and fast to compute. We evaluate our classification method both on benchmark data from a mobile mapping platform and on a variety of large, terrestrial laser scans with greatly varying point density. The proposed feature set outperforms the state of the art with respect to per-point classification accuracy, while at the same time being much faster to compute.

  17. Fast live-cell conventional fluorophore nanoscopy with ImageJ through super-resolution radial fluctuations

    PubMed Central

    Gustafsson, Nils; Culley, Siân; Ashdown, George; Owen, Dylan M.; Pereira, Pedro Matos; Henriques, Ricardo

    2016-01-01

    Despite significant progress, high-speed live-cell super-resolution studies remain limited to specialized optical setups, generally requiring intense phototoxic illumination. Here, we describe a new analytical approach, super-resolution radial fluctuations (SRRF), provided as a fast graphics processing unit-enabled ImageJ plugin. In the most challenging data sets for super-resolution, such as those obtained in low-illumination live-cell imaging with GFP, we show that SRRF is generally capable of achieving resolutions better than 150 nm. Meanwhile, for data sets similar to those obtained in PALM or STORM imaging, SRRF achieves resolutions approaching those of standard single-molecule localization analysis. The broad applicability of SRRF and its performance at low signal-to-noise ratios allows super-resolution using modern widefield, confocal or TIRF microscopes with illumination orders of magnitude lower than methods such as PALM, STORM or STED. We demonstrate this by super-resolution live-cell imaging over timescales ranging from minutes to hours. PMID:27514992

  18. Ultra-fast DNA-based multiplex convection PCR method for meat species identification with possible on-site applications.

    PubMed

    Song, Kyung-Young; Hwang, Hyun Jin; Kim, Jeong Hee

    2017-08-15

    The aim of this study was to develop an ultra-fast molecular detection method for meat identification using convection Palm polymerase chain reaction (PCR). The mitochondrial cytochrome b (Cyt b) gene was used as a target gene. Amplicon size was designed to be different for beef, lamb, and pork. When these primer sets were used, each species-specific set specifically detected the target meat species in singleplex and multiplex modes in a 24min PCR run. The detection limit was 1pg of DNA for each meat species. The convection PCR method could detect as low as 1% of meat adulteration. The stability of the assay was confirmed using thermal processed meats. We also showed that direct PCR can be successfully performed with mixed meats and food samples. These results suggest that the developed assay may be useful in the authentication of meats and meat products in laboratory and rapid on-site applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Profiling optimization for big data transfer over dedicated channels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yun, D.; Wu, Qishi; Rao, Nageswara S

    The transfer of big data is increasingly supported by dedicated channels in high-performance networks, where transport protocols play an important role in maximizing applicationlevel throughput and link utilization. The performance of transport protocols largely depend on their control parameter settings, but it is prohibitively time consuming to conduct an exhaustive search in a large parameter space to find the best set of parameter values. We propose FastProf, a stochastic approximation-based transport profiler, to quickly determine the optimal operational zone of a given data transfer protocol/method over dedicated channels. We implement and test the proposed method using both emulations based onmore » real-life performance measurements and experiments over physical connections with short (2 ms) and long (380 ms) delays. Both the emulation and experimental results show that FastProf significantly reduces the profiling overhead while achieving a comparable level of end-to-end throughput performance with the exhaustive search-based approach.« less

  20. Fast segmentation of stained nuclei in terabyte-scale, time resolved 3D microscopy image stacks.

    PubMed

    Stegmaier, Johannes; Otte, Jens C; Kobitski, Andrei; Bartschat, Andreas; Garcia, Ariel; Nienhaus, G Ulrich; Strähle, Uwe; Mikut, Ralf

    2014-01-01

    Automated analysis of multi-dimensional microscopy images has become an integral part of modern research in life science. Most available algorithms that provide sufficient segmentation quality, however, are infeasible for a large amount of data due to their high complexity. In this contribution we present a fast parallelized segmentation method that is especially suited for the extraction of stained nuclei from microscopy images, e.g., of developing zebrafish embryos. The idea is to transform the input image based on gradient and normal directions in the proximity of detected seed points such that it can be handled by straightforward global thresholding like Otsu's method. We evaluate the quality of the obtained segmentation results on a set of real and simulated benchmark images in 2D and 3D and show the algorithm's superior performance compared to other state-of-the-art algorithms. We achieve an up to ten-fold decrease in processing times, allowing us to process large data sets while still providing reasonable segmentation results.

  1. An ``Openable,'' High-Strength Gradient Set for Orthopedic MRI

    NASA Astrophysics Data System (ADS)

    Crozier, Stuart; Roffmann, Wolfgang U.; Luescher, Kurt; Snape-Jenkinson, Christopher; Forbes, Lawrence K.; Doddrell, David M.

    1999-07-01

    A novel three-axis gradient set and RF resonator for orthopedic MRI has been designed and constructed. The set is openable and may be wrapped around injured joints. The design methodology used was the minimization of magnetic field spherical harmonics by simulated annealing. Splitting of the longitudinal coil presents the major design challenge to a fully openable gradient set and in order to efficiently design such coils, we have developed a new fast algorithm for determining the magnetic field spherical harmonics generated by an arc of multiturn wire. The algorithm allows a realistic impression of the effect of split longitudinal designs. A prototype set was constructed based on the new designs and tested in a 2-T clinical research system. The set generated 12 mT/m/A with a linear region of 12 cm and a switching time of 100 μs, conforming closely with theoretical predictions. Preliminary images from the set are presented.

  2. Leveraging transcript quantification for fast computation of alternative splicing profiles.

    PubMed

    Alamancos, Gael P; Pagès, Amadís; Trincado, Juan L; Bellora, Nicolás; Eyras, Eduardo

    2015-09-01

    Alternative splicing plays an essential role in many cellular processes and bears major relevance in the understanding of multiple diseases, including cancer. High-throughput RNA sequencing allows genome-wide analyses of splicing across multiple conditions. However, the increasing number of available data sets represents a major challenge in terms of computation time and storage requirements. We describe SUPPA, a computational tool to calculate relative inclusion values of alternative splicing events, exploiting fast transcript quantification. SUPPA accuracy is comparable and sometimes superior to standard methods using simulated as well as real RNA-sequencing data compared with experimentally validated events. We assess the variability in terms of the choice of annotation and provide evidence that using complete transcripts rather than more transcripts per gene provides better estimates. Moreover, SUPPA coupled with de novo transcript reconstruction methods does not achieve accuracies as high as using quantification of known transcripts, but remains comparable to existing methods. Finally, we show that SUPPA is more than 1000 times faster than standard methods. Coupled with fast transcript quantification, SUPPA provides inclusion values at a much higher speed than existing methods without compromising accuracy, thereby facilitating the systematic splicing analysis of large data sets with limited computational resources. The software is implemented in Python 2.7 and is available under the MIT license at https://bitbucket.org/regulatorygenomicsupf/suppa. © 2015 Alamancos et al.; Published by Cold Spring Harbor Laboratory Press for the RNA Society.

  3. Performance of a Highly Sensitive Mycobacterium tuberculosis Complex Real-Time PCR Assay for Diagnosis of Pulmonary Tuberculosis in a Low-Prevalence Setting: a Prospective Intervention Study.

    PubMed

    Vinuesa, Víctor; Borrás, Rafael; Briones, María Luisa; Clari, María Ángeles; Cresencio, Vicenta; Giménez, Estela; Muñoz, Carmen; Oltra, Rosa; Servera, Emilio; Scheelje, Talia; Tornero, Carlos; Navarro, David

    2018-05-01

    The potential impact of routine real-time PCR testing of respiratory specimens from patients with presumptive tuberculosis in terms of diagnostic accuracy and time to tuberculosis treatment inception in low-prevalence settings remains largely unexplored. We conducted a prospective intervention cohort study. Respiratory specimens from 1,020 patients were examined by acid-fast bacillus smear microscopy, tested by a real-time Mycobacterium tuberculosis complex PCR assay (Abbott RealTi me MTB PCR), and cultured in mycobacterial media. Seventeen patients tested positive by PCR (5 were acid-fast bacillus smear positive and 12 acid-fast bacillus smear negative), and Mycobacterium tuberculosis was recovered from cultures for 12 of them. Patients testing positive by PCR and negative by culture ( n = 5) were treated and deemed to have responded to antituberculosis therapy. There were no PCR-negative/culture-positive cases, and none of the patients testing positive for nontuberculous mycobacteria ( n = 20) yielded a positive PCR result. The data indicated that routine testing of respiratory specimens from patients with presumptive tuberculosis by the RealTi me MTB PCR assay improves the tuberculosis diagnostic yield and may reduce the time to antituberculosis treatment initiation. On the basis of our data, we propose a novel mycobacterial laboratory algorithm for tuberculosis diagnosis. Copyright © 2018 American Society for Microbiology.

  4. The age related slow and fast contributions to the overall changes in tibialis anterior contractile features disclosed by maximal single twitch scan.

    PubMed

    Orizio, Claudio; Cogliati, Marta; Bissolotti, Luciano; Diemont, Bertrand; Gobbo, Massimiliano; Celichowski, Jan

    2016-01-01

    This work aimed to verify if maximal electrically evoked single twitch (STmax) scan discloses the relative functional weight of fast and slow small bundles of fibres (SBF) in determining the contractile features of tibialis anterior (TA) with ageing. SBFs were recruited by TA main motor point stimulation through 60 increasing levels of stimulation (LS): 20 stimuli at 2Hz for each LS. The lowest and highest LS provided the least ST and STmax, respectively. The scanned STmax was decomposed into individual SBF STs. They were identified when twitches from adjacent LS were significantly different and then subtracted from each other. Nine young (Y) and eleven old (O) subjects were investigated. Contraction time (CT) and STarea/STpeak (A/PT) were calculated per each SBF ST. 143 and 155 SBF STs were obtained in Y and O, respectively. Y: CT and A/PT range: 45-105ms and 67-183mNs/mN, respectively. Literature data set TA fast fibres at 34% so, from the arrays of CT and A/PT, 65ms and 100mNs/mN were identified as the upper limit for SBF fast ST classification. O: no SBF ST could be classified as fast. STmax scan reveals age-related changes in the relative contribution of fast and slow SBFs to the overall muscle mechanics. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. The Generalized Centroid Difference method for lifetime measurements via γ-γ coincidences using large fast-timing arrays

    NASA Astrophysics Data System (ADS)

    Régis, J.-M.; Jolie, J.; Mach, H.; Simpson, G. S.; Blazhev, A.; Pascovici, G.; Pfeiffer, M.; Rudigier, M.; Saed-Samii, N.; Warr, N.; Blanc, A.; de France, G.; Jentschel, M.; Köster, U.; Mutti, P.; Soldner, T.; Ur, C. A.; Urban, W.; Bruce, A. M.; Drouet, F.; Fraile, L. M.; Ilieva, S.; Korten, W.; Kröll, T.; Lalkovski, S.; Mărginean, S.; Paziy, V.; Podolyák, Zs.; Regan, P. H.; Stezowski, O.; Vancraeyenest, A.

    2015-05-01

    A novel method for direct electronic "fast-timing" lifetime measurements of nuclear excited states via γ-γ coincidences using an array equipped with N very fast high-resolution LaBr3(Ce) scintillator detectors is presented. The generalized centroid difference method provides two independent "start" and "stop" time spectra obtained without any correction by a superposition of the N(N - 1)/2 calibrated γ-γ time difference spectra of the N detector fast-timing system. The two fast-timing array time spectra correspond to a forward and reverse gating of a specific γ-γ cascade and the centroid difference as the time shift between the centroids of the two time spectra provides a picosecond-sensitive mirror-symmetric observable of the set-up. The energydependent mean prompt response difference between the start and stop events is calibrated and used as a single correction for lifetime determination. These combined fast-timing array mean γ-γ zero-time responses can be determined for 40 keV < Eγ < 1.4 MeV with a precision better than 10 ps using a 152Eu γ-ray source. The new method is described with examples of (n,γ) and (n,f,γ) experiments performed at the intense cold-neutron beam facility PF1B of the Institut Laue-Langevin in Grenoble, France, using 16 LaBr3(Ce) detectors within the EXILL&FATIMA campaign in 2013. The results are discussed with respect to possible systematic errors induced by background contributions.

  6. Unified System Of Data On Materials And Processes

    NASA Technical Reports Server (NTRS)

    Key, Carlo F.

    1989-01-01

    Wide-ranging sets of data for aerospace industry described. Document describes Materials and Processes Technical Information System (MAPTIS), computerized set of integrated data bases for use by NASA and aerospace industry. Stores information in standard format for fast retrieval in searches and surveys of data. Helps engineers select materials and verify their properties. Promotes standardized nomenclature as well as standarized tests and presentation of data. Format of document of photographic projection slides used in lectures. Presents examples of reports from various data bases.

  7. Fast-Acting Rubber-To-Coated-Aluminum Adhesive

    NASA Technical Reports Server (NTRS)

    Comer, Dawn A.; Novak, Howard; Vazquez, Mark

    1991-01-01

    Cyanoacrylate adhesive used to join rubber to coated aluminum easier to apply and more effective. One-part material applied in single coat to aluminum treated previously with epoxy primer and top coat. Parts mated as soon as adhesive applied; no drying necessary. Sets in 5 minutes. Optionally, accelerator brushed onto aluminum to reduce setting time to 30 seconds. Clamping parts together unnecessary. Adhesive comes in four formulations, all based on ethyl cyanoacrylate with various amounts of ethylene copolymer rubber, poly(methyl methacrylate), silicon dioxide, hydroquinone, and phthalic anhydride.

  8. Fast and automatic depth control of iterative bone ablation based on optical coherence tomography data

    NASA Astrophysics Data System (ADS)

    Fuchs, Alexander; Pengel, Steffen; Bergmeier, Jan; Kahrs, Lüder A.; Ortmaier, Tobias

    2015-07-01

    Laser surgery is an established clinical procedure in dental applications, soft tissue ablation, and ophthalmology. The presented experimental set-up for closed-loop control of laser bone ablation addresses a feedback system and enables safe ablation towards anatomical structures that usually would have high risk of damage. This study is based on combined working volumes of optical coherence tomography (OCT) and Er:YAG cutting laser. High level of automation in fast image data processing and tissue treatment enables reproducible results and shortens the time in the operating room. For registration of the two coordinate systems a cross-like incision is ablated with the Er:YAG laser and segmented with OCT in three distances. The resulting Er:YAG coordinate system is reconstructed. A parameter list defines multiple sets of laser parameters including discrete and specific ablation rates as ablation model. The control algorithm uses this model to plan corrective laser paths for each set of laser parameters and dynamically adapts the distance of the laser focus. With this iterative control cycle consisting of image processing, path planning, ablation, and moistening of tissue the target geometry and desired depth are approximated until no further corrective laser paths can be set. The achieved depth stays within the tolerances of the parameter set with the smallest ablation rate. Specimen trials with fresh porcine bone have been conducted to prove the functionality of the developed concept. Flat bottom surfaces and sharp edges of the outline without visual signs of thermal damage verify the feasibility of automated, OCT controlled laser bone ablation with minimal process time.

  9. Test of the SO(6) selection rule in 196Pt using cold-neutron capture

    NASA Astrophysics Data System (ADS)

    Jolie, J.; Régis, J.-M.; Wilmsen, D.; Saed-Samii, N.; Pfeiffer, M.; Warr, N.; Blanc, A.; Jentschel, M.; Köster, U.; Mutti, P.; Soldner, T.; Simpson, G. S.; De France, G.; Urban, W.; Drouet, F.; Vancraeyenest, A.; Bruce, A. M.; Roberts, O. J.; Fraile, L. M.; Paziy, V.; Ignatov, A.; Kröll, Th.; Ivanova, D.; Kisyov, S.; Lalkovski, S.; Podolyak, Zs.; Regan, P. H.; Wilson, E.; Korten, W.; Ur, C. A.; Lica, R.; Marginean, N.

    2015-02-01

    At the PF1B cold-neutron beam line of the Institut Laue Langevin, the EXILL&FATIMA array, consisting of EXOGAM Ge detectors and fast LaBr3(Ce) scintillators, was used to perform fast electronic timing measurements after the 195Pt(n, γ) reaction using a highly collimated cold-neutron beam. An upper lifetime limit was obtained for the third 0+ state in 196Pt. As this state is the lowest state of the σ = N - 2 set of SO(6) states, the selection rule which forbids E2 transitions to the lower lying σ = N could be tested.

  10. A fast 3-D object recognition algorithm for the vision system of a special-purpose dexterous manipulator

    NASA Technical Reports Server (NTRS)

    Hung, Stephen H. Y.

    1989-01-01

    A fast 3-D object recognition algorithm that can be used as a quick-look subsystem to the vision system for the Special-Purpose Dexterous Manipulator (SPDM) is described. Global features that can be easily computed from range data are used to characterize the images of a viewer-centered model of an object. This algorithm will speed up the processing by eliminating the low level processing whenever possible. It may identify the object, reject a set of bad data in the early stage, or create a better environment for a more powerful algorithm to carry the work further.

  11. Determination of the fast-neutron-induced fission cross-section of 242Pu at nELBE

    NASA Astrophysics Data System (ADS)

    Kögler, Toni; Beyer, Roland; Junghans, Arnd R.; Schwengner, Ronald; Wagner, Andreas

    2018-03-01

    The fast-neutron-induced fission cross section of 242Pu was determined in the energy range of 0.5 MeV to 10MeV at the neutron time-of-flight facility nELBE. Using a parallel-plate fission ionization chamber this quantity was measured relative to 235U(n,f). The number of target nuclei was thereby calculated by means of measuring the spontaneous fission rate of 242Pu. An MCNP 6 neutron transport simulation was used to correct the relative cross section for neutron scattering. The determined results are in good agreement with current experimental and evaluated data sets.

  12. Prompting one low-fat, high-fiber selection in a fast-food restaurant.

    PubMed

    Wagner, J L; Winett, R A

    1988-01-01

    Evidence increasingly links a high-fat, low-fiber diet to coronary heart disease and certain site cancers, indicating a need for large-scale dietary change. Studies showing the effectiveness of particular procedures in specific settings are important at this point. The present study, using an A-B-A-B design and sales data from computerized cash registers, replicated and extended previous work by showing that inexpensive prompts (i.e., signs and fliers) in a national fast-food restaurant could increase the sales of salads, a low-fat, high-fiber menu selection. Suggestions also are made pertinent to more widespread use of the procedures.

  13. Femtosecond soliton source with fast and broad spectral tunability.

    PubMed

    Masip, Martin E; Rieznik, A A; König, Pablo G; Grosz, Diego F; Bragas, Andrea V; Martinez, Oscar E

    2009-03-15

    We present a complete set of measurements and numerical simulations of a femtosecond soliton source with fast and broad spectral tunability and nearly constant pulse width and average power. Solitons generated in a photonic crystal fiber, at the low-power coupling regime, can be tuned in a broad range of wavelengths, from 850 to 1200 nm using the input power as the control parameter. These solitons keep almost constant time duration (approximately 40 fs) and spectral widths (approximately 20 nm) over the entire measured spectra regardless of input power. Our numerical simulations agree well with measurements and predict a wide working wavelength range and robustness to input parameters.

  14. Blackworms, Blood Vessel Pulsations and Drug Effects.

    ERIC Educational Resources Information Center

    Lesiuk, Nalena M.; Drewes, Charles D.

    1999-01-01

    Introduces the freshwater oligochaete worm, lumbriculus variegatus (common name: blackworms), an organism that is well suited for classroom study because of its closed circulatory system. Describes a set of simple, fast, noninvasive, and inexpensive methods for observing pulsations of the worm's dorsal blood vessels under baseline conditions, and…

  15. Waves and Tsunami Project

    ERIC Educational Resources Information Center

    Frashure, K. M.; Chen, R. F.; Stephen, R. A.; Bolmer, T.; Lavin, M.; Strohschneider, D.; Maichle, R.; Micozzi, N.; Cramer, C.

    2007-01-01

    Demonstrating wave processes quantitatively in the classroom using standard classroom tools (such as Slinkys and wave tanks) can be difficult. For example, waves often travel too fast for students to actually measure amplitude or wavelength. Also, when teaching propagating waves, reflections from the ends set up standing waves, which can confuse…

  16. The Children Speak

    ERIC Educational Resources Information Center

    Jacobs, Erin

    2008-01-01

    Public spaces that promote play and discovery are popping up everywhere from metropolitan cities to rural and suburban settings. Playgrounds such as David Rockwell's Imagination Playground in New York City and the Memorial Park Playground in Wilsonville, Oregon, present a stark contrast to the steel and plastic structures found at fast-food…

  17. The Influence of the Type of Lime on the Hygric Behaviour and Bio-Receptivity of Hemp Lime Composites Used for Rendering Applications in Sustainable New Construction and Repair Works

    PubMed Central

    Arizzi, Anna; Brümmer, Monika; Martín-Sanchez, Inés; Cultrone, Giuseppe; Viles, Heather

    2015-01-01

    The benefits of using sustainable building materials are linked not only to the adoption of manufacturing processes that entail reduced pollution, CO2 emissions and energy consumption, but also to the onset of improved performance in the building. In particular, hemp-lime composite shows low shrinkage and high thermal and acoustic insulating properties. However, this material also shows a great ability to absorb water, an aspect that can turn out to be negative for the long-term durability of the building. For this reason, the hygric properties of hemp-based composites need to be studied to ensure the correct use of this material in construction and repair works. The water absorption, drying and transpirability of hemp composites made with aerial (in the form of dry powder and putty) and hydraulic limes were investigated here and related to the microbial growth induced by the water movements within the material. Results show that hemp-natural hydraulic lime mixes exhibit the highest transpirability and drying rate, the lowest water absorption by immersion and capillary uptake and the least intense microbial attack and chromatic change. A microscopical study of the hemp shives also related their great ability to absorb water to the near-irreversible swelling of their structure under dry-wet conditions. PMID:26017563

  18. Laser Sintered Porous Ti-6Al-4V Implants Stimulate Vertical Bone Growth.

    PubMed

    Cheng, Alice; Cohen, David J; Kahn, Adrian; Clohessy, Ryan M; Sahingur, Kaan; Newton, Joseph B; Hyzy, Sharon L; Boyan, Barbara D; Schwartz, Zvi

    2017-08-01

    The objective of this study was to examine the ability of 3D implants with trabecular-bone-inspired porosity and micro-/nano-rough surfaces to enhance vertical bone ingrowth. Porous Ti-6Al-4V constructs were fabricated via laser-sintering and processed to obtain micro-/nano-rough surfaces. Male and female human osteoblasts were seeded on constructs to analyze cell morphology and response. Implants were then placed on rat calvaria for 10 weeks to assess vertical bone ingrowth, mechanical stability and osseointegration. All osteoblasts showed higher levels of osteocalcin, osteoprotegerin, vascular endothelial growth factor and bone morphogenetic protein 2 on porous constructs compared to solid laser-sintered controls. Porous implants placed in vivo resulted in an average of 3.1 ± 0.6 mm 3 vertical bone growth and osseointegration within implant pores and had significantly higher pull-out strength values than solid implants. New bone formation and pull-out strength was not improved with the addition of demineralized bone matrix putty. Scanning electron images and histological results corroborated vertical bone growth. This study indicates that Ti-6Al-4V implants fabricated by additive manufacturing to have porosity based on trabecular bone and post-build processing to have micro-/nano-surface roughness can support vertical bone growth in vivo, and suggests that these implants may be used clinically to increase osseointegration in challenging patient cases.

  19. Technical Evaluation Motor no. 5 (TEM-5)

    NASA Technical Reports Server (NTRS)

    Cook, M.

    1990-01-01

    Technical Evaluation Motor No. 5 (TEM-5) was static test fired at the Thiokol Corporation Static Test Bay T-97. TEM-5 was a full scale, full duration static test fire of a high performance motor (HPM) configuration solid rocket motor (SRM). The primary purpose of TEM static tests is to recover SRM case and nozzle hardware for use in the redesigned solid rocket motor (RSRM) flight program. Inspection and instrumentation data indicate that the TEM-5 static test firing was successful. The ambient temperature during the test was 41 F and the propellant mean bulk temperature (PMBT) was 72 F. Ballistics performance values were within the specified requirements. The overall performance of the TEM-5 components and test equipment was nominal. Dissembly inspection revealed that joint putty was in contact with the inner groove of the inner primary seal of the ignitor adapter-to-forward dome (inner) joint gasket; this condition had not occurred on any previous static test motor or flight RSRM. While no qualification issues were addressed on TEM-5, two significant component changes were evaluated. Those changes were a new vented assembly process for the case-to-nozzle joint and the installation of two redesigned field joint protection systems. Performance of the vented case-to-nozzle joint assembly was successful, and the assembly/performance differences between the two field joint protection system (FJPS) configurations were compared.

  20. Equations of State and High-Pressure Phases of Explosives

    NASA Astrophysics Data System (ADS)

    Peiris, Suhithi M.; Gump, Jared C.

    Energetic materials, being the collective name for explosives, propellants, pyrotechnics, and other flash-bang materials, span a wide range of composite chemical formulations. Most militarily used energetics are solids composed of particles of the pure energetic material held together by a binder. Commonly used binders include various oils, waxes, and polymers or plasticizers, and the composite is melt cast, cured, or pressed to achieve the necessary mechanical properties (gels, putties, sheets, solid blocks, etc.) of the final energetic material. Mining, demolition, and other industries use liquid energetics that are similarly composed of an actual energetic material or oxidizer together with a fuel, that is to be mixed and poured for detonation. Pure energetic materials that are commonly used are nitroglycerine, ammonium nitrate, ammonium or sodium perchlorate, trinitrotoluene (TNT), HMX, RDX, and TATB. All of them are molecular materials or molecular ions that when initiated or insulted undergoes rapid decomposition with excessive liberation of heat resulting in the formation of stable final products. When the final products are gases, and they are rapidly produced, the sudden pressure increase creates a shock wave. When decomposition is so rapid that the reaction moves through the explosive faster than the speed of sound in the unreacted explosive, the material is said to detonate. Typically, energetic materials that undergo detonation are known as high explosives (HEs) and energetic materials that burn rapidly or deflagrate are known as low explosives and/or propellants.

  1. The influence of the type of lime on the hygric behaviour and bio-receptivity of hemp lime composites used for rendering applications in sustainable new construction and repair works.

    PubMed

    Arizzi, Anna; Brümmer, Monika; Martín-Sanchez, Inés; Cultrone, Giuseppe; Viles, Heather

    2015-01-01

    The benefits of using sustainable building materials are linked not only to the adoption of manufacturing processes that entail reduced pollution, CO2 emissions and energy consumption, but also to the onset of improved performance in the building. In particular, hemp-lime composite shows low shrinkage and high thermal and acoustic insulating properties. However, this material also shows a great ability to absorb water, an aspect that can turn out to be negative for the long-term durability of the building. For this reason, the hygric properties of hemp-based composites need to be studied to ensure the correct use of this material in construction and repair works. The water absorption, drying and transpirability of hemp composites made with aerial (in the form of dry powder and putty) and hydraulic limes were investigated here and related to the microbial growth induced by the water movements within the material. Results show that hemp-natural hydraulic lime mixes exhibit the highest transpirability and drying rate, the lowest water absorption by immersion and capillary uptake and the least intense microbial attack and chromatic change. A microscopical study of the hemp shives also related their great ability to absorb water to the near-irreversible swelling of their structure under dry-wet conditions.

  2. Possible utilization of acrylic paint and copper phthalocyanine pigment sludge for vermiculture.

    PubMed

    Majumdar, Deepanjan; Buch, Vaidehi; Macwan, Praisy; Patel, Jignesh

    2010-05-01

    Sludge generated from water treatment plants in two different paint and pigment manufacturing industries, one manufacturing CPC Green (copper phthalocyanine green) and the other acrylic (pure and styrene) washable distempers, synthetic enamels, fillers and putties, were used for culturing earthworms (Eisenia foetida Savigny). The possibility of getting a quality vermicompost was also explored. The sludges were used pure and mixed with month-old cow dung at 1:1, 1:2, 1:3, 2:1 and 3:1 ratios (sludge:cow dung). In pure sludges and in the 3:1 ratio, earthworms did not survive. Earthworms had very low survival in CPC Green sludge and its mixtures while acrylic paint sludge was very efficient in supporting worm growth and worm castings were generated quickly. Both sludges were alkaline, non-saline, but had appreciable Ca, Al, Pb, Zn, and Mn. CPC Green had high Cu (12,900 mg kg(-1)) and acrylic paint sludge had high total Cr (155 mg kg(-1)). High Ca and Al in both came from water treatment chemicals (lime and alum), while CPC Green itself is a copper-based pigment. The sludges were suitable for land application with regard to their metal contents, except for Cu in CPC Green. CPC Green did not support proper growth of plants (green gram, Vigna radiata (L). R. Wilcz.), while acrylic paint sludge supported growth in pure form and mixtures with soil.

  3. Romano-British wall paintings: Raman spectroscopic analysis of fragments from two urban sites of early military colonisation.

    PubMed

    Edwards, H G M; Middleton, P S; Hargreaves, M D

    2009-08-01

    Raman spectroscopic analyses of 1st century AD Romano-British villa wall-painting fragments from two important military and early urban centres at Colchester and Lincoln have demonstrated some interesting contrasts in technique and palette usage. Colchester, the earliest fortified settlement, developed a sophisticated painting and craft industry compared with Lincoln in the assimilation of novel substrate preparation ideas and pigment adoption. The earliest use of the rather rare purple mineral pigment, caput mortuum, hitherto reported in only a few Roman villas elsewhere in mainland Europe, is in evidence in this early phase settlement and the use of gypsum as a special ground preparation agent as an additive to the more common limewash putty to enhance the effect of the use of lazurite as a pigment is worthy of note in this context. Otherwise, the pigments are seen to be those that are quite normally encountered in Roman villas, namely, haematite, goethite, terre verte, and carbon. The results of this study indicate that at Colchester there was a continued development in technique into the colonial phase compared with a stagnation in Lincoln; these scientific results have created a stimulus for further historical research into pigment and techniques development for wall paintings at the fringe of the Roman Empire in the 1st-3rd Centuries AD.

  4. Romano-British wall paintings: Raman spectroscopic analysis of fragments from two urban sites of early military colonisation

    NASA Astrophysics Data System (ADS)

    Edwards, H. G. M.; Middleton, P. S.; Hargreaves, M. D.

    2009-08-01

    Raman spectroscopic analyses of 1st century AD Romano-British villa wall-painting fragments from two important military and early urban centres at Colchester and Lincoln have demonstrated some interesting contrasts in technique and palette usage. Colchester, the earliest fortified settlement, developed a sophisticated painting and craft industry compared with Lincoln in the assimilation of novel substrate preparation ideas and pigment adoption. The earliest use of the rather rare purple mineral pigment, caput mortuum, hitherto reported in only a few Roman villas elsewhere in mainland Europe, is in evidence in this early phase settlement and the use of gypsum as a special ground preparation agent as an additive to the more common limewash putty to enhance the effect of the use of lazurite as a pigment is worthy of note in this context. Otherwise, the pigments are seen to be those that are quite normally encountered in Roman villas, namely, haematite, goethite, terre verte, and carbon. The results of this study indicate that at Colchester there was a continued development in technique into the colonial phase compared with a stagnation in Lincoln; these scientific results have created a stimulus for further historical research into pigment and techniques development for wall paintings at the fringe of the Roman Empire in the 1st-3rd Centuries AD.

  5. Experiment and Reactive-Burn Modeling in the RDX Based Explosive XTX 8004

    NASA Astrophysics Data System (ADS)

    Johnson, Carl; Murphy, Mike; Gustavsen, Rick; Jackson, Scott; Vincent, Samuel

    2015-06-01

    XTX 8004 consists of 80 wt. % cyclotrimethylenetrinitramine (RDX), and 20 wt. % Sylgard 182, a silicone rubber used as a binder. Nominal density is 1.5 g/cm3. Uncured XTX 8004 is putty like and can be molded or extruded. The XTX 8004 detonation product Hugoniot calibration was obtained from cylinder tests using a genetic algorithm approach to parameterize a Jones-Wilkins-Lee (JWL) equation of state. Additionally, we conducted four gas-gun experiments that were instrumented with embedded electromagnetic particle velocity gauges. These provided wave profiles to which we calibrated an Ignition and Growth reactive burn (IGRB) model in ALE3D for 1-D shock to detonation transitions. Further, acceptor and donor XTX 8004 were extruded into opposite sides of a monolithic polymethylmethacrylate (PMMA) block with a known thickness of PMMA forming the attenuator plate, the so-called monolithic gap test (MGT). Detonation and initiation in the XTX 8004 was recorded using multiple ultra-high-speed images of the position of the shock front in the PMMA. Input to the acceptor charge was estimated from stress wave profiles photographed inside the attenuator as well as with photonic Doppler velocimetry (PDV) measurements of the free surface velocity beneath the attenuator plate. Results were simulated using IGRB in ALE3D. Parameterization of IGRB to 1-D vs. 2-D experiments will be discussed.

  6. A preliminary fast may potentiate response to a subsequent low-salt, low-fat vegan diet in the management of hypertension - fasting as a strategy for breaking metabolic vicious cycles.

    PubMed

    McCarty, M F

    2003-05-01

    Although a salted diet appears to be a sine qua non for the development of essential hypertension, low-salt diets often have a modest or even negligible impact on the blood pressure of hypertensives; this suggests that salt, perhaps often acting in concert with other aspects of a modern, rich diet, may set in place certain metabolic vicious cycles that sustain blood pressure elevation even when dietary salt is eliminated. Therapeutic fasting is known to lower elevated blood pressure - presumably in large part because it minimizes insulin secretion - and may have the potential to break some of these vicious cycles. Goldhamer has recently reported that a regimen comprised of a water-only fast of moderate duration, followed by a transition to a low-fat, low-salt, whole-food vegan diet, achieves dramatic reductions in the blood pressure of hypertensives, such that the large majority of patients can be restored to normotensive status, in the absence of any drug therapy. Although long-term follow-up of these subjects has been sporadic, the available data suggest that these large reductions is blood pressure can be conserved in patients who remain compliant with the follow-up diet - in other words, a 'cure' for hypertension may be feasible. If a protein-sparing modified fast can be shown to be virtually as effective as a total fast for achieving these benefits, it may be possible to implement this regimen safely on an outpatient basis. The ability of therapeutic fasts to break metabolic vicious cycles may also contribute to the efficacy of fasting in the treatment of type 2 diabetes and autoimmune disorders. As a general principle, if a metabolic disorder is susceptible to prevention - but not reversal - by a specific diet, and therapeutic fasting has a temporary favorable impact on this disorder, then a more definitive therapy may consist of a therapeutic fast, followed up by the protective diet as a maintenance regimen.

  7. Usefulness of Routine Periodic Fasting to Lower Risk of Coronary Artery Disease among Patients Undergoing Coronary Angiography

    PubMed Central

    Horne, Benjamin D.; May, Heidi T.; Anderson, Jeffrey L.; Kfoury, Abdallah G.; Bailey, Beau M.; McClure, Brian S.; Renlund, Dale G.; Lappé, Donald L.; Carlquist, John F.; Fisher, Patrick W.; Pearson, Robert R.; Bair, Tami L.; Adams, Ted D.; Muhlestein, Joseph B.

    2008-01-01

    Coronary artery disease (CAD) is common and multi-factorial. Members of the Church of Jesus Christ of Latter-day Saints (LDS, or Mormons) in Utah may have lower cardiac mortality than other Utahns and the US population. While the LDS proscription of smoking likely contributes to lower cardiac risk, it is unknown whether other shared behaviors also contribute. This study evaluated potential CAD-associated effects of fasting. Patients (N1=4,629) enrolled in the Intermountain Heart Collaborative Study registry (1994-2002) were evaluated for association of religious preference with CAD diagnosis (≥70% coronary stenosis on angiography) or no CAD (normal coronaries, <10% stenosis). Consequently, another set of patients (N2=448) were surveyed (2004-2006) for association of behavioral factors with CAD, with the primary variable being routine fasting (i.e., abstinence from food and drink). Secondary survey measures included proscription of alcohol, tea, and coffee, social support, and religious worship patterns. In population 1 (initial), 61% of LDS and 66% of all others had CAD (adjusted [including for smoking]: odds ratio [OR]=0.81; p=0.009). In population 2 (survey), fasting was associated with lower risk of CAD (64% vs. 76% CAD; OR=0.55, CI=0.35, 0.87; p=0.010) and this remained after adjustment for traditional risk factors (OR=0.46, CI=0.27, 0.81; p=0.007). Fasting was also associated with lower diabetes prevalence (p=0.048). In regression models entering other secondary behavioral measures, fasting remained significant with similar effect size. In conclusion, not only proscription of tobacco, but also routine periodic fasting was associated with lower risk of CAD. PMID:18805103

  8. The Consistency in Macronutrient Oxidation and the Role for Epinephrine in the Response to Fasting and Overfeeding

    PubMed Central

    Schlögl, Mathias; Piaggi, Paolo; Hohenadel, Maximilian; Graham, Alexis; Bonfiglio, Susan; Krakoff, Jonathan; Thearle, Marie S.

    2017-01-01

    Context: In humans, dietary vs intraindividual determinants of macronutrient oxidation preference and the role of the sympathetic nervous system (SNS) during short-term overfeeding and fasting are unclear. Objective: To understand the influence on metabolic changes of diet and SNS during 24 hours of overfeeding. Design, Setting, Participants, and Interventions: While residing on a clinical research unit, 64 participants with normal glucose regulation were assessed during energy balance, fasting, and four 24-hour overfeeding diets, given in random order. The overfeeding diets contained 200% of energy requirements and varied macronutrient proportions: (1) standard (50% carbohydrate, 20% protein, and 30% fat); (2) 75% carbohydrate; (3) 60% fat; and (4) 3% protein. Main Outcome Measures: Twenty-four–hour energy expenditure (EE) and macronutrient oxidation rates were measured in an indirect calorimeter during the dietary interventions, with concomitant measurement of urinary catecholamines and free cortisol. Results: EE decreased with fasting (−7.7% ± 4.8%; P < 0.0001) and increased with overfeeding. The smallest increase occurred during consumption of the diet with 3% protein (2.7% ± 4.5%; P = 0.001) and the greatest during the diet with 75% carbohydrate (13.8 ± 5.7%; P < 0.0001). Approximately 60% of macronutrient oxidation was determined by diet and 20% by intrinsic factors (P < 0.0001). Only urinary epinephrine differed between fasting and overfeeding diets (Δ = 2.25 ± 2.9 µg/24h; P < 0.0001). During fasting, higher urinary epinephrine concentrations correlated with smaller reductions in EE (ρ = 0.34; P = 0.01). Conclusions: Independent from dietary macronutrient proportions, there is a strong individual contribution to fuel preference that remains consistent across diets. Higher urinary epinephrine levels may reflect the importance of epinephrine in maintaining EE during fasting. PMID:27820654

  9. [Cardiac risk profile in diabetes mellitus and impaired fasting glucose].

    PubMed

    Schaan, Beatriz D'Agord; Harzheim, Erno; Gus, Iseu

    2004-08-01

    Mortality of diabetic patients is higher than that of the population at large, and mainly results from cardiovascular diseases. The purpose of the present study was to identify the prevalence of cardiovascular risk factors in subjects with diabetes mellitus (DM) or abnormal fasting glucose (FG) in order to guide health actions. A population-based cross-sectional study was carried out in a representative random cluster sampling of 1,066 adult urban population (> or =20 years) in the state of Rio Grande do Sul between 1999 and 2000. A structured questionnaire on coronary risk factors was applied and sociodemographic characteristics of all adults older than 20 years living in the same dwelling were collected. Subjects were clinically evaluated and blood samples were obtained for measuring total cholesterol and fasting glycemia. Statistical analysis was performed using Stata 7 and a 5% significance level was set. Categorical variables were compared by Pearson's chi-square and continuous variables were compared using Student's t-test or Anova and multivariate analysis, all controlled for the cluster effect. Of 992 subjects, 12.4% were diabetic and 7.4% had impaired fasting glucose. Among the risk factors evaluated, subjects who presented any kind of glucose homeostasis abnormality were at a higher prevalence of obesity (17.8, 29.2 and 35.3% in healthy subjects, impaired fasting glucose and DM respectively, p<0.001), hypertension (30.1, 56.3 and 50.5% in healthy subjects, impaired fasting glucose and DM, respectively, p<0.001), and hypercholesterolemia (23.2, 35.1 and 39.5 in healthy subjects, impaired fasting glucose and DM respectively, p=0.01). Subjects with any kind of glucose homeostasis abnormality represent a group, which preventive individual and population health policies should target since they have higher prevalence of coronary artery disease risk factors.

  10. The interrater and test-retest reliability of the Home Falls and Accidents Screening Tool (HOME FAST) in Malaysia: Using raters with a range of professional backgrounds.

    PubMed

    Romli, Muhammad Hibatullah; Mackenzie, Lynette; Lovarini, Meryl; Tan, Maw Pin; Clemson, Lindy

    2017-06-01

    Falls can be a devastating issue for older people living in the community, including those living in Malaysia. Health professionals and community members have a responsibility to ensure that older people have a safe home environment to reduce the risk of falls. Using a standardised screening tool is beneficial to intervene early with this group. The Home Falls and Accidents Screening Tool (HOME FAST) should be considered for this purpose; however, its use in Malaysia has not been studied. Therefore, the aim of this study was to evaluate the interrater and test-retest reliability of the HOME FAST with multiple professionals in the Malaysian context. A cross-sectional design was used to evaluate interrater reliability where the HOME FAST was used simultaneously in the homes of older people by 2 raters and a prospective design was used to evaluate test-retest reliability with a separate group of older people at different times in their homes. Both studies took place in an urban area of Kuala Lumpur. Professionals from 9 professional backgrounds participated as raters in this study, and a group of 51 community older people were recruited for the interrater reliability study and another group of 30 for the test-retest reliability study. The overall agreement was moderate for interrater reliability and good for test-retest reliability. The HOME FAST was consistently rated by different professionals, and no bias was found among the multiple raters. The HOME FAST can be used with confidence by a variety of professionals across different settings. The HOME FAST can become a universal tool to screen for home hazards related to falls. © 2017 John Wiley & Sons, Ltd.

  11. EFFECTS OF RAMADAN FASTING ON BLOOD PRESSURE IN NORMOTENSIVE MALES.

    PubMed

    Samad, Fatima; Qazi, Fahd; Pervaiz, Mohammad B; Kella, Danesh K; Mansoor, Maryah; Osmani, Bushra Z; Mir, Fazia; Kadir, Muhammad Masood

    2015-01-01

    Research has been done to investigate the effect of intermittent complete fasting on human physiological parameters but the effect of fasting on blood pressure remains relatively unexplored. Research in animal models suggests a hypotensive effect with an undetermined mechanism. Muslims worldwide fast daily from dawn to dusk throughout the Islamic month of Ramadan. This study was to investigate the proposed hypotensive effect of Ramadan fasting in males over A period of 20 days and to study the relationship of the pattern of blood pressure variation with body mass index change. A repeated measures observational study design was implemented with convenient sampling. Study group included 40 normotensive, non-smoker males with no known comorbidities between the ages of 18-40 who fasted daily in the month of Ramadan. One set of BP readings, each, was taken one week before the start of Ramadan and on the 7th, 14th and 21st day of Ramadan which included pre and post Iftar measurements along with other variables. Data was analysed by repeated measures ANOVA using SPSS. The differences were compared with critical values generated by Tukey's Method. There was a significant drop in systolic BP of 7.61 mmHg before Iftar, 2.72 mm-Hg after Iftar (p<0.005). There was a significant effect of Ramadan on diastolic BP (p<0.005), the drop being 3.19 mmHg. The drop in body mass index was significant only before Iftar at 0.3 kg/m2 (p<0.005). Pulse rate showed a significant drop of 7.79 bpm before Iftar and a significant rise of 3.96 bpm (p<0.005). Intermittent fasting causes a drop in both systolic and diastolic blood pressure in normotensive males.

  12. Fast-food consumption, diet quality and body weight: cross-sectional and prospective associations in a community sample of working adults

    PubMed Central

    Barnes, Timothy L; French, Simone A; Mitchell, Nathan R; Wolfson, Julian

    2018-01-01

    Objective To examine the association between fast-food consumption, diet quality and body weight in a community sample of working adults. Design Cross-sectional and prospective analysis of anthropometric, survey and dietary data from adults recruited to participate in a worksite nutrition intervention. Participants self-reported frequency of fast-food consumption per week. Nutrient intakes and diet quality, using the Healthy Eating Index-2010 (HEI-2010), were computed from dietary recalls collected at baseline and 6 months. Setting Metropolitan medical complex, Minneapolis, MN, USA. Subjects Two hundred adults, aged 18–60 years. Results Cross-sectionally, fast-food consumption was significantly associated with higher daily total energy intake (β = 72·5, P = 0·005), empty calories (β = 0·40, P = 0·006) and BMI (β = 0·73, P =0·011), and lower HEI-2010 score (β = −1·23, P =0·012), total vegetables (β = −0·14, P =0·004), whole grains (β = −0·39, P =0·005), fibre (β = −0·83, P =0·002), Mg (β = −6·99, P =0·019) and K (β = −57·5, P =0·016). Over 6 months, change in fast-food consumption was not significantly associated with changes in energy intake or BMI, but was significantly inversely associated with total intake of vegetables (β = −0·14, P =0·034). Conclusions Frequency of fast-food consumption was significantly associated with higher energy intake and poorer diet quality cross-sectionally. Six-month change in fast-food intake was small, and not significantly associated with overall diet quality or BMI. PMID:26074150

  13. The relationship between new media exposure and fast food consumption among Chinese children and adolescents in school: a rural-urban comparison.

    PubMed

    Hansstein, Francesca Valeria; Hong, Yu; Di, Chen

    2017-09-01

    In recent decades, China has experienced an exponential growth in the number of internet users, especially among the youngest population, as well as a rapid proliferation of Western-type fast food restaurants. The health consequences of internet availability and fast food consumption among youth have been largely studied in Western countries, but few studies have focused on China. This paper has two goals. The first is to evaluate the differences in new media exposure and preferences for fast foods between rural and urban areas. The second goal is to test the association between new media exposure and fast food consumption. The targets of this analysis are Chinese children and adolescents aged 6-18 attending school at the time of the interview. Research hypotheses were tested using mean-groups comparisons for differences between rural urban sub-samples, and logistic regressions with odds ratios to estimate the relationship between media exposure and preferences towards fast foods. Cross-sectional data from the 2009 China Health and Nutrition Survey were employed. Watching online videos and playing computer games are behaviors associated with higher probabilities of eating at fast food restaurants in both rural and urban young residents, with higher odds in rural areas. Surfing the internet is associated with higher odds of being overweight in both rural and urban settings. Results also show that children living in rural areas spend significantly more time playing computer games, watching TV and videotapes, but less time doing homework than their urban peers. This paper suggests that monitoring the nutritional effects of new media exposure in China is of key importance in order to develop adequate health promotion policies, in both rural and urban areas.

  14. Efficient enumeration of monocyclic chemical graphs with given path frequencies

    PubMed Central

    2014-01-01

    Background The enumeration of chemical graphs (molecular graphs) satisfying given constraints is one of the fundamental problems in chemoinformatics and bioinformatics because it leads to a variety of useful applications including structure determination and development of novel chemical compounds. Results We consider the problem of enumerating chemical graphs with monocyclic structure (a graph structure that contains exactly one cycle) from a given set of feature vectors, where a feature vector represents the frequency of the prescribed paths in a chemical compound to be constructed and the set is specified by a pair of upper and lower feature vectors. To enumerate all tree-like (acyclic) chemical graphs from a given set of feature vectors, Shimizu et al. and Suzuki et al. proposed efficient branch-and-bound algorithms based on a fast tree enumeration algorithm. In this study, we devise a novel method for extending these algorithms to enumeration of chemical graphs with monocyclic structure by designing a fast algorithm for testing uniqueness. The results of computational experiments reveal that the computational efficiency of the new algorithm is as good as those for enumeration of tree-like chemical compounds. Conclusions We succeed in expanding the class of chemical graphs that are able to be enumerated efficiently. PMID:24955135

  15. Polarization-modulated second harmonic generation ellipsometric microscopy at video rate.

    PubMed

    DeWalt, Emma L; Sullivan, Shane Z; Schmitt, Paul D; Muir, Ryan D; Simpson, Garth J

    2014-08-19

    Fast 8 MHz polarization modulation coupled with analytical modeling, fast beam-scanning, and synchronous digitization (SD) have enabled simultaneous nonlinear optical Stokes ellipsometry (NOSE) and polarized laser transmittance imaging with image acquisition rates up to video rate. In contrast to polarimetry, in which the polarization state of the exiting beam is recorded, NOSE enables recovery of the complex-valued Jones tensor of the sample that describes all polarization-dependent observables of the measurement. Every video-rate scan produces a set of 30 images (10 for each detector with three detectors operating in parallel), each of which corresponds to a different polarization-dependent result. Linear fitting of this image set contracts it down to a set of five parameters for each detector in second harmonic generation (SHG) and three parameters for the transmittance of the incident beam. These parameters can in turn be used to recover the Jones tensor elements of the sample. Following validation of the approach using z-cut quartz, NOSE microscopy was performed for microcrystals of both naproxen and glucose isomerase. When weighted by the measurement time, NOSE microscopy was found to provide a substantial (>7 decades) improvement in the signal-to-noise ratio relative to our previous measurements based on the rotation of optical elements and a 3-fold improvement relative to previous single-point NOSE approaches.

  16. OPERATIONAL EXPERIENCE WITH FAST FIBER-OPTIC BEAM LOSS MONITORS FOR THE ADVANCED PHOTON SOURCE STORAGE RING SUPERCONDUCTING UNDULATORS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dooling, J.; Harkay, K.; Sajaev, V.

    Fast fiber-optic (FFO) beam loss monitors (BLMs) installed with the first two superconducting undulators (SCUs) in the Advanced Photon Source storage ring have proven to be a useful diagnostic for measuring deposited charge (energy) during rapid beam loss events. The first set of FFOBLMs were installed outside the cryostat of the short SCU, a 0.33-m long device, above and below the beam centerline. The second set are mounted with the first 1.1-mlong SCU within the cryostat, on the outboard and inboard sides of the vacuum chamber. The next 1.1-m-long SCU is scheduled to replace the short SCU later in 2016more » and will be fitted with FFOBLMs in a manner similar to original 1.1-m device. The FFOBLMs were employed to set timing and voltage for the abort kicker (AK) system. The AK helps to prevent quenching of the SCUs during beam dumps [1] by directing the beam away from the SC magnet windings. The AK is triggered by the Machine Protection System (MPS). In cases when the AK fails to prevent quenching, the FFOBLMs show that losses often begin before detection by the MPS.« less

  17. EnsMart: A Generic System for Fast and Flexible Access to Biological Data

    PubMed Central

    Kasprzyk, Arek; Keefe, Damian; Smedley, Damian; London, Darin; Spooner, William; Melsopp, Craig; Hammond, Martin; Rocca-Serra, Philippe; Cox, Tony; Birney, Ewan

    2004-01-01

    The EnsMart system (www.ensembl.org/EnsMart) provides a generic data warehousing solution for fast and flexible querying of large biological data sets and integration with third-party data and tools. The system consists of a query-optimized database and interactive, user-friendly interfaces. EnsMart has been applied to Ensembl, where it extends its genomic browser capabilities, facilitating rapid retrieval of customized data sets. A wide variety of complex queries, on various types of annotations, for numerous species are supported. These can be applied to many research problems, ranging from SNP selection for candidate gene screening, through cross-species evolutionary comparisons, to microarray annotation. Users can group and refine biological data according to many criteria, including cross-species analyses, disease links, sequence variations, and expression patterns. Both tabulated list data and biological sequence output can be generated dynamically, in HTML, text, Microsoft Excel, and compressed formats. A wide range of sequence types, such as cDNA, peptides, coding regions, UTRs, and exons, with additional upstream and downstream regions, can be retrieved. The EnsMart database can be accessed via a public Web site, or through a Java application suite. Both implementations and the database are freely available for local installation, and can be extended or adapted to `non-Ensembl' data sets. PMID:14707178

  18. Specific Early Number Skills Mediate the Association between Executive Functioning Skills and Mathematics Achievement

    ERIC Educational Resources Information Center

    Fuhs, Mary Wagner; Hornburg, Caroline Byrd; McNeil, Nicole M.

    2016-01-01

    A growing literature reports significant associations between children's executive functioning skills and their mathematics achievement. The purpose of this study was to examine if specific early number skills, such as quantity discrimination, number line estimation, number sets identification, fast counting, and number word comprehension, mediate…

  19. A Fast Turn-Around Facility for Very Large Scale Integration (VLSI)

    DTIC Science & Technology

    1982-06-01

    statistics determination, the first test mask set will use the MATRIX chip design which was recently developed here at Stanford. This chip provides...reached when the basewidth is reduced to zero. Such devices, variably known as depleted- base transistors or bipolar static-induction transitors , have been

  20. Fast and Scalable Gaussian Process Modeling with Applications to Astronomical Time Series

    NASA Astrophysics Data System (ADS)

    Foreman-Mackey, Daniel; Agol, Eric; Ambikasaran, Sivaram; Angus, Ruth

    2017-12-01

    The growing field of large-scale time domain astronomy requires methods for probabilistic data analysis that are computationally tractable, even with large data sets. Gaussian processes (GPs) are a popular class of models used for this purpose, but since the computational cost scales, in general, as the cube of the number of data points, their application has been limited to small data sets. In this paper, we present a novel method for GPs modeling in one dimension where the computational requirements scale linearly with the size of the data set. We demonstrate the method by applying it to simulated and real astronomical time series data sets. These demonstrations are examples of probabilistic inference of stellar rotation periods, asteroseismic oscillation spectra, and transiting planet parameters. The method exploits structure in the problem when the covariance function is expressed as a mixture of complex exponentials, without requiring evenly spaced observations or uniform noise. This form of covariance arises naturally when the process is a mixture of stochastically driven damped harmonic oscillators—providing a physical motivation for and interpretation of this choice—but we also demonstrate that it can be a useful effective model in some other cases. We present a mathematical description of the method and compare it to existing scalable GP methods. The method is fast and interpretable, with a range of potential applications within astronomical data analysis and beyond. We provide well-tested and documented open-source implementations of this method in C++, Python, and Julia.

  1. The Role of the Virtual Astronomical Observatory in the Era of Big Data

    NASA Astrophysics Data System (ADS)

    Berriman, G. B.; Hanisch, R. J.; Lazio, T. J.

    2013-01-01

    The Virtual Observatory (VO) is realizing global electronic integration of astronomy data. The rapid growth in the size and complexity of data sets is transforming the computing landscape in astronomy. One of the long-term goals of the U.S. VO project, the Virtual Astronomical Observatory (VAO), is development of an information backbone that responds to this growth. Such a backbone will, when complete, provide innovative mechanisms for fast discovery of, and access to, massive data sets, and services that enable distributed storage, publication processing of large datasets. All these services will be built so that new projects can incorporate them as part of their data management and processing plans. Services under development to date include a general purpose indexing scheme for fast access to data sets, a cross-comparison engine that operate on catalogs of 1 billion records or more, and an interface for managing distributed data sets and connecting them to data discovery and analysis tools. The VAO advises projects on technology solutions for their data access and processing needs, and recently advised the Sagan Workshop on using cloud computing to support hands-on data analysis sessions for 150+ participants. Acknowledgements: The Virtual Astronomical Observatory (VAO) is managed by the VAO, LLC, a non-profit company established as a partnership of the Associated Universities, Inc. and the Association of Universities for Research in Astronomy, Inc. The VAO is sponsored by the National Science Foundation and the National Aeronautics and Space Administration.

  2. metAlignID: a high-throughput software tool set for automated detection of trace level contaminants in comprehensive LECO two-dimensional gas chromatography time-of-flight mass spectrometry data.

    PubMed

    Lommen, Arjen; van der Kamp, Henk J; Kools, Harrie J; van der Lee, Martijn K; van der Weg, Guido; Mol, Hans G J

    2012-11-09

    A new alternative data processing tool set, metAlignID, is developed for automated pre-processing and library-based identification and concentration estimation of target compounds after analysis by comprehensive two-dimensional gas chromatography with mass spectrometric detection. The tool set has been developed for and tested on LECO data. The software is developed to run multi-threaded (one thread per processor core) on a standard PC (personal computer) under different operating systems and is as such capable of processing multiple data sets simultaneously. Raw data files are converted into netCDF (network Common Data Form) format using a fast conversion tool. They are then preprocessed using previously developed algorithms originating from metAlign software. Next, the resulting reduced data files are searched against a user-composed library (derived from user or commercial NIST-compatible libraries) (NIST=National Institute of Standards and Technology) and the identified compounds, including an indicative concentration, are reported in Excel format. Data can be processed batch wise. The overall time needed for conversion together with processing and searching of 30 raw data sets for 560 compounds is routinely within an hour. The screening performance is evaluated for detection of pesticides and contaminants in raw data obtained after analysis of soil and plant samples. Results are compared to the existing data-handling routine based on proprietary software (LECO, ChromaTOF). The developed software tool set, which is freely downloadable at www.metalign.nl, greatly accelerates data-analysis and offers more options for fine-tuning automated identification toward specific application needs. The quality of the results obtained is slightly better than the standard processing and also adds a quantitative estimate. The software tool set in combination with two-dimensional gas chromatography coupled to time-of-flight mass spectrometry shows great potential as a highly-automated and fast multi-residue instrumental screening method. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. FGF21 and the late adaptive response to starvation in humans.

    PubMed

    Fazeli, Pouneh K; Lun, Mingyue; Kim, Soo M; Bredella, Miriam A; Wright, Spenser; Zhang, Yang; Lee, Hang; Catana, Ciprian; Klibanski, Anne; Patwari, Parth; Steinhauser, Matthew L

    2015-11-03

    In mice, FGF21 is rapidly induced by fasting, mediates critical aspects of the adaptive starvation response, and displays a number of positive metabolic properties when administered pharmacologically. In humans, however, fasting does not consistently increase FGF21, suggesting a possible evolutionary divergence in FGF21 function. Moreover, many key aspects of FGF21 function in mice have been identified in the context of transgenic overexpression or administration of supraphysiologic doses, rather than in a physiologic setting. Here, we explored the dynamics and function of FGF21 in human volunteers during a 10-day fast. Unlike mice, which show an increase in circulating FGF21 after only 6 hours, human subjects did not have a notable surge in FGF21 until 7 to 10 days of fasting. Moreover, we determined that FGF21 induction was associated with decreased thermogenesis and adiponectin, an observation that directly contrasts with previous reports based on supraphysiologic dosing. Additionally, FGF21 levels increased after ketone induction, demonstrating that endogenous FGF21 does not drive starvation-mediated ketogenesis in humans. Instead, a longitudinal analysis of biologically relevant variables identified serum transaminases--markers of tissue breakdown--as predictors of FGF21. These data establish FGF21 as a fasting-induced hormone in humans and indicate that FGF21 contributes to the late stages of adaptive starvation, when it may regulate the utilization of fuel derived from tissue breakdown.

  4. Building fast well-balanced two-stage numerical schemes for a model of two-phase flows

    NASA Astrophysics Data System (ADS)

    Thanh, Mai Duc

    2014-06-01

    We present a set of well-balanced two-stage schemes for an isentropic model of two-phase flows arisen from the modeling of deflagration-to-detonation transition in granular materials. The first stage is to absorb the source term in nonconservative form into equilibria. Then in the second stage, these equilibria will be composed into a numerical flux formed by using a convex combination of the numerical flux of a stable Lax-Friedrichs-type scheme and the one of a higher-order Richtmyer-type scheme. Numerical schemes constructed in such a way are expected to get the interesting property: they are fast and stable. Tests show that the method works out until the parameter takes on the value CFL, and so any value of the parameter between zero and this value is expected to work as well. All the schemes in this family are shown to capture stationary waves and preserves the positivity of the volume fractions. The special values of the parameter 0,1/2,1/(1+CFL), and CFL in this family define the Lax-Friedrichs-type, FAST1, FAST2, and FAST3 schemes, respectively. These schemes are shown to give a desirable accuracy. The errors and the CPU time of these schemes and the Roe-type scheme are calculated and compared. The constructed schemes are shown to be well-balanced and faster than the Roe-type scheme.

  5. A Novel Framework Based on FastICA for High Density Surface EMG Decomposition

    PubMed Central

    Chen, Maoqi; Zhou, Ping

    2015-01-01

    This study presents a progressive FastICA peel-off (PFP) framework for high density surface electromyogram (EMG) decomposition. The novel framework is based on a shift-invariant model for describing surface EMG. The decomposition process can be viewed as progressively expanding the set of motor unit spike trains, which is primarily based on FastICA. To overcome the local convergence of FastICA, a “peel off” strategy (i.e. removal of the estimated motor unit action potential (MUAP) trains from the previous step) is used to mitigate the effects of the already identified motor units, so more motor units can be extracted. Moreover, a constrained FastICA is applied to assess the extracted spike trains and correct possible erroneous or missed spikes. These procedures work together to improve the decomposition performance. The proposed framework was validated using simulated surface EMG signals with different motor unit numbers (30, 70, 91) and signal to noise ratios (SNRs) (20, 10, 0 dB). The results demonstrated relatively large numbers of extracted motor units and high accuracies (high F1-scores). The framework was also tested with 111 trials of 64-channel electrode array experimental surface EMG signals during the first dorsal interosseous (FDI) muscle contraction at different intensities. On average 14.1 ± 5.0 motor units were identified from each trial of experimental surface EMG signals. PMID:25775496

  6. FastChem: A computer program for efficient complex chemical equilibrium calculations in the neutral/ionized gas phase with applications to stellar and planetary atmospheres

    NASA Astrophysics Data System (ADS)

    Stock, Joachim W.; Kitzmann, Daniel; Patzer, A. Beate C.; Sedlmayr, Erwin

    2018-06-01

    For the calculation of complex neutral/ionized gas phase chemical equilibria, we present a semi-analytical versatile and efficient computer program, called FastChem. The applied method is based on the solution of a system of coupled nonlinear (and linear) algebraic equations, namely the law of mass action and the element conservation equations including charge balance, in many variables. Specifically, the system of equations is decomposed into a set of coupled nonlinear equations in one variable each, which are solved analytically whenever feasible to reduce computation time. Notably, the electron density is determined by using the method of Nelder and Mead at low temperatures. The program is written in object-oriented C++ which makes it easy to couple the code with other programs, although a stand-alone version is provided. FastChem can be used in parallel or sequentially and is available under the GNU General Public License version 3 at https://github.com/exoclime/FastChem together with several sample applications. The code has been successfully validated against previous studies and its convergence behavior has been tested even for extreme physical parameter ranges down to 100 K and up to 1000 bar. FastChem converges stable and robust in even most demanding chemical situations, which posed sometimes extreme challenges for previous algorithms.

  7. Modeling of the UAE Wind Turbine for Refinement of FAST{_}AD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jonkman, J. M.

    The Unsteady Aerodynamics Experiment (UAE) research wind turbine was modeled both aerodynamically and structurally in the FAST{_}AD wind turbine design code, and its response to wind inflows was simulated for a sample of test cases. A study was conducted to determine why wind turbine load magnitude discrepancies-inconsistencies in aerodynamic force coefficients, rotor shaft torque, and out-of-plane bending moments at the blade root across a range of operating conditions-exist between load predictions made by FAST{_}AD and other modeling tools and measured loads taken from the actual UAE wind turbine during the NASA-Ames wind tunnel tests. The acquired experimental test data representmore » the finest, most accurate set of wind turbine aerodynamic and induced flow field data available today. A sample of the FAST{_}AD model input parameters most critical to the aerodynamics computations was also systematically perturbed to determine their effect on load and performance predictions. Attention was focused on the simpler upwind rotor configuration, zero yaw error test cases. Inconsistencies in input file parameters, such as aerodynamic performance characteristics, explain a noteworthy fraction of the load prediction discrepancies of the various modeling tools.« less

  8. Fasting - the ultimate diet?

    PubMed

    Johnstone, A M

    2007-05-01

    Adult humans often undertake acute fasts for cosmetic, religious or medical reasons. For example, an estimated 14% of US adults have reported using fasting as a means to control body weight and this approach has long been advocated as an intermittent treatment for gross refractory obesity. There are unique historical data sets on extreme forms of food restriction that give insight into the consequences of starvation or semi-starvation in previously healthy, but usually non-obese subjects. These include documented medical reports on victims of hunger strike, famine and prisoners of war. Such data provide a detailed account on how the body adapts to prolonged starvation. It has previously been shown that fasting for the biblical period of 40 days and 40 nights is well within the overall physiological capabilities of a healthy adult. However, the specific effects on the human body and mind are less clearly documented, either in the short term (hours) or in the longer term (days). This review asks the following three questions, pertinent to any weight-loss therapy, (i) how effective is the regime in achieving weight loss, (ii) what impact does it have on psychology? and finally, (iii) does it work long-term?

  9. Molecule formation and infrared emission in fast interstellar shocks. I Physical processes

    NASA Technical Reports Server (NTRS)

    Hollenbach, D.; Mckee, C. F.

    1979-01-01

    The paper analyzes the structure of fast shocks incident upon interstellar gas of ambient density from 10 to the 7th per cu cm, while focusing on the problems of formation and destruction of molecules and infrared emission in the cooling, neutral post shock gas. It is noted that such fast shocks initially dissociate almost all preexisting molecules. Discussion covers the physical processes which determine the post shock structure between 10 to the 4 and 10 to the 2 K. It is shown that the chemistry of important molecular coolants H2, CO, OH, and H2O, as well as HD and CH, is reduced to a relatively small set of gas phase and grain surface reactions. Also, the chemistry follows the slow conversion of atomic hydrogen into H2, which primarily occurs on grain surfaces. The dependence of this H2 formation rate on grain and gas temperatures is examined and the survival of grains behind fast shocks is discussed. Post shock heating and cooling rates are calculated and an appropriate, analytic, universal cooling function is developed for molecules other than hydrogen which includes opacities from both the dust and the lines.

  10. Modulation format identification enabled by the digital frequency-offset loading technique for hitless coherent transceiver.

    PubMed

    Fu, Songnian; Xu, Zuying; Lu, Jianing; Jiang, Hexun; Wu, Qiong; Hu, Zhouyi; Tang, Ming; Liu, Deming; Chan, Calvin Chun-Kit

    2018-03-19

    We propose a blind and fast modulation format identification (MFI) enabled by the digital frequency-offset (FO) loading technique for hitless coherent transceiver. Since modulation format information is encoded to the FO distribution during digital signal processing (DSP) at the transmitter side (Tx), we can use the fast Fourier transformation based FO estimation (FFT-FOE) method to obtain the FO distribution of individual data block after constant modulus algorithm (CMA) pre-equalization at the receiver side, in order to realize non-data-aided (NDA) and fast MFI. The obtained FO can be also used for subsequent FO compensation (FOC), without additional complexity. We numerically investigate and experimentally verify the proposed MFI with high accuracy and fast format switching among 28 Gbaud dual-polarization (DP)-4/8/16/64QAM, time domain hybrid-4/16QAM, and set partitioning (SP)-128QAM. In particular, the proposed MFI brings no performance degradation, in term of tolerance of amplified spontaneous emission (ASE) noise, laser linewidth, and fiber nonlinearity. Finally, a hitless coherent transceiver enabled by the proposed MFI with switching-block of only 2048 symbols is demonstrated over 1500 km standard single mode fiber (SSMF) transmission.

  11. Patch forest: a hybrid framework of random forest and patch-based segmentation

    NASA Astrophysics Data System (ADS)

    Xie, Zhongliu; Gillies, Duncan

    2016-03-01

    The development of an accurate, robust and fast segmentation algorithm has long been a research focus in medical computer vision. State-of-the-art practices often involve non-rigidly registering a target image with a set of training atlases for label propagation over the target space to perform segmentation, a.k.a. multi-atlas label propagation (MALP). In recent years, the patch-based segmentation (PBS) framework has gained wide attention due to its advantage of relaxing the strict voxel-to-voxel correspondence to a series of pair-wise patch comparisons for contextual pattern matching. Despite a high accuracy reported in many scenarios, computational efficiency has consistently been a major obstacle for both approaches. Inspired by recent work on random forest, in this paper we propose a patch forest approach, which by equipping the conventional PBS with a fast patch search engine, is able to boost segmentation speed significantly while retaining an equal level of accuracy. In addition, a fast forest training mechanism is also proposed, with the use of a dynamic grid framework to efficiently approximate data compactness computation and a 3D integral image technique for fast box feature retrieval.

  12. ProbFAST: Probabilistic functional analysis system tool.

    PubMed

    Silva, Israel T; Vêncio, Ricardo Z N; Oliveira, Thiago Y K; Molfetta, Greice A; Silva, Wilson A

    2010-03-30

    The post-genomic era has brought new challenges regarding the understanding of the organization and function of the human genome. Many of these challenges are centered on the meaning of differential gene regulation under distinct biological conditions and can be performed by analyzing the Multiple Differential Expression (MDE) of genes associated with normal and abnormal biological processes. Currently MDE analyses are limited to usual methods of differential expression initially designed for paired analysis. We proposed a web platform named ProbFAST for MDE analysis which uses Bayesian inference to identify key genes that are intuitively prioritized by means of probabilities. A simulated study revealed that our method gives a better performance when compared to other approaches and when applied to public expression data, we demonstrated its flexibility to obtain relevant genes biologically associated with normal and abnormal biological processes. ProbFAST is a free accessible web-based application that enables MDE analysis on a global scale. It offers an efficient methodological approach for MDE analysis of a set of genes that are turned on and off related to functional information during the evolution of a tumor or tissue differentiation. ProbFAST server can be accessed at http://gdm.fmrp.usp.br/probfast.

  13. ProbFAST: Probabilistic Functional Analysis System Tool

    PubMed Central

    2010-01-01

    Background The post-genomic era has brought new challenges regarding the understanding of the organization and function of the human genome. Many of these challenges are centered on the meaning of differential gene regulation under distinct biological conditions and can be performed by analyzing the Multiple Differential Expression (MDE) of genes associated with normal and abnormal biological processes. Currently MDE analyses are limited to usual methods of differential expression initially designed for paired analysis. Results We proposed a web platform named ProbFAST for MDE analysis which uses Bayesian inference to identify key genes that are intuitively prioritized by means of probabilities. A simulated study revealed that our method gives a better performance when compared to other approaches and when applied to public expression data, we demonstrated its flexibility to obtain relevant genes biologically associated with normal and abnormal biological processes. Conclusions ProbFAST is a free accessible web-based application that enables MDE analysis on a global scale. It offers an efficient methodological approach for MDE analysis of a set of genes that are turned on and off related to functional information during the evolution of a tumor or tissue differentiation. ProbFAST server can be accessed at http://gdm.fmrp.usp.br/probfast. PMID:20353576

  14. Generation of skeletal mechanism by means of projected entropy participation indices

    NASA Astrophysics Data System (ADS)

    Paolucci, Samuel; Valorani, Mauro; Ciottoli, Pietro Paolo; Galassi, Riccardo Malpica

    2017-11-01

    When the dynamics of reactive systems develop very-slow and very-fast time scales separated by a range of active time scales, with gaps in the fast/active and slow/active time scales, then it is possible to achieve multi-scale adaptive model reduction along-with the integration of the ODEs using the G-Scheme. The scheme assumes that the dynamics is decomposed into active, slow, fast, and invariant subspaces. We derive expressions that establish a direct link between time scales and entropy production by using estimates provided by the G-Scheme. To calculate the contribution to entropy production, we resort to a standard model of a constant pressure, adiabatic, batch reactor, where the mixture temperature of the reactants is initially set above the auto-ignition temperature. Numerical experiments show that the contribution to entropy production of the fast subspace is of the same magnitude as the error threshold chosen for the identification of the decomposition of the tangent space, and the contribution of the slow subspace is generally much smaller than that of the active subspace. The information on entropy production associated with reactions within each subspace is used to define an entropy participation index that is subsequently utilized for model reduction.

  15. Fast software-based volume rendering using multimedia instructions on PC platforms and its application to virtual endoscopy

    NASA Astrophysics Data System (ADS)

    Mori, Kensaku; Suenaga, Yasuhito; Toriwaki, Jun-ichiro

    2003-05-01

    This paper describes a software-based fast volume rendering (VolR) method on a PC platform by using multimedia instructions, such as SIMD instructions, which are currently available in PCs' CPUs. This method achieves fast rendering speed through highly optimizing software rather than an improved rendering algorithm. In volume rendering using a ray casting method, the system requires fast execution of the following processes: (a) interpolation of voxel or color values at sample points, (b) computation of normal vectors (gray-level gradient vectors), (c) calculation of shaded values obtained by dot-products of normal vectors and light source direction vectors, (d) memory access to a huge area, and (e) efficient ray skipping at translucent regions. The proposed software implements these fundamental processes in volume rending by using special instruction sets for multimedia processing. The proposed software can generate virtual endoscopic images of a 3-D volume of 512x512x489 voxel size by volume rendering with perspective projection, specular reflection, and on-the-fly normal vector computation on a conventional PC without any special hardware at thirteen frames per second. Semi-translucent display is also possible.

  16. Effects of a westernized lifestyle on the association between fasting serum nonesterified fatty acids and insulin secretion in Japanese men.

    PubMed

    Kamei, Nozomu; Yamane, Kiminori; Nakanishi, Shuhei; Ishida, Kazufumi; Ohtaki, Megu; Okubo, Masamichi; Kohno, Nobuoki

    2005-06-01

    The effects of the prolonged elevation of nonesterified fatty acid (NEFA) levels on insulin secretion have been controversial and thought to be sex-specific. To investigate the association between a westernized lifestyle and the effects of NEFA on insulin secretion in Japanese men, we examined 67 nondiabetic Japanese-American men and 220 nondiabetic native Japanese men who underwent a 75-g oral glucose tolerance test (OGTT). Most Japanese Americans we surveyed are genetically identical to Japanese living in Japan, but their lifestyle is more westernized. Sets of multiple regression analyses were performed to evaluate the relationship between the sum of the immunoreactive insulin (IRI) levels during the OGTT ((Sigma)IRI) and clinical parameters. Japanese Americans had higher levels of fasting IRI, (Sigma)IRI, and a higher insulin resistance index (homeostasis model assessment for insulin resistance [HOMA-IR]) than native Japanese, whereas there were no significant differences in fasting NEFA and triglyceride levels. A multiple regression analysis adjusted for age, fasting triglycerides, and body mass index (BMI) demonstrated that the fasting NEFA level was an independent determinant of the (Sigma)IRI only in Japanese-American men ( P = .001), but not in native Japanese men ( P = .054). Even when HOMA-IR was included in models instead of BMI, the NEFA level was a significant variable of (Sigma)IRI only in Japanese Americans ( P < .001), and not in native Japanese ( P = .098). In addition, a multiple regression analysis adjusted for age, fasting triglycerides, and BMI demonstrated that the fasting NEFA level was the only independent determinant of (Sigma)C-peptide in Japanese-American men ( P = .041). In conclusion, NEFA seems to be associated with insulin secretion independent of obesity or HOMA-IR. A westernized lifestyle may increase the effects of serum fasting NEFA levels on total insulin secretion after a glucose load in Japanese men.

  17. IPO: a tool for automated optimization of XCMS parameters.

    PubMed

    Libiseller, Gunnar; Dvorzak, Michaela; Kleb, Ulrike; Gander, Edgar; Eisenberg, Tobias; Madeo, Frank; Neumann, Steffen; Trausinger, Gert; Sinner, Frank; Pieber, Thomas; Magnes, Christoph

    2015-04-16

    Untargeted metabolomics generates a huge amount of data. Software packages for automated data processing are crucial to successfully process these data. A variety of such software packages exist, but the outcome of data processing strongly depends on algorithm parameter settings. If they are not carefully chosen, suboptimal parameter settings can easily lead to biased results. Therefore, parameter settings also require optimization. Several parameter optimization approaches have already been proposed, but a software package for parameter optimization which is free of intricate experimental labeling steps, fast and widely applicable is still missing. We implemented the software package IPO ('Isotopologue Parameter Optimization') which is fast and free of labeling steps, and applicable to data from different kinds of samples and data from different methods of liquid chromatography - high resolution mass spectrometry and data from different instruments. IPO optimizes XCMS peak picking parameters by using natural, stable (13)C isotopic peaks to calculate a peak picking score. Retention time correction is optimized by minimizing relative retention time differences within peak groups. Grouping parameters are optimized by maximizing the number of peak groups that show one peak from each injection of a pooled sample. The different parameter settings are achieved by design of experiments, and the resulting scores are evaluated using response surface models. IPO was tested on three different data sets, each consisting of a training set and test set. IPO resulted in an increase of reliable groups (146% - 361%), a decrease of non-reliable groups (3% - 8%) and a decrease of the retention time deviation to one third. IPO was successfully applied to data derived from liquid chromatography coupled to high resolution mass spectrometry from three studies with different sample types and different chromatographic methods and devices. We were also able to show the potential of IPO to increase the reliability of metabolomics data. The source code is implemented in R, tested on Linux and Windows and it is freely available for download at https://github.com/glibiseller/IPO . The training sets and test sets can be downloaded from https://health.joanneum.at/IPO .

  18. Variability in the reported energy, total fat and saturated fat content in fast food products across ten countries

    PubMed Central

    Ziauddeen, Nida; Fitt, Emily; Edney, Louise; Dunford, Elizabeth; Neal, Bruce; Jebb, Susan A.

    2016-01-01

    Objective Fast foods are often energy dense and offered in large serving sizes. Observational data has linked the consumption of fast food to an increased risk of obesity and related diseases. Design We surveyed the reported energy, total fat and saturated fat contents, and serving sizes, of fast food items from five major chains across 10 countries, comparing product categories as well as specific food items available in most countries. Setting MRC Human Nutrition Research (HNR), Cambridge Subjects Data for 2961 food and drink products were collected, with most from Canada (n=550) and fewest from United Arab Emirates (n=106). Results There was considerable variability in energy and fat content of fast food across countries, reflecting both the portfolio of products, and serving size variability. Differences in total energy between countries were particularly noted for chicken dishes (649-1197kJ/100g) and sandwiches (552-1050kJ/100g). When comparing the same product between countries variations were consistently observed in total energy and fat content (g/100g) with extreme variation in McDonald’s Chicken McNuggets with 12g total fat (g/100g) in Germany compared to 21.1g in New Zealand. Conclusions These cross-country variations highlight the possibility for further product reformulation in many countries to reduce nutrients of concern and improve the nutritional profiles of fast food products around the world. Standardisation of serving sizes towards the lower end of the range would also help to reduce the risk of overconsumption. PMID:25702788

  19. The effect of aborting ongoing movements on end point position estimation.

    PubMed

    Itaguchi, Yoshihiro; Fukuzawa, Kazuyoshi

    2013-11-01

    The present study investigated the impact of motor commands to abort ongoing movement on position estimation. Participants carried out visually guided reaching movements on a horizontal plane with their eyes open. By setting a mirror above their arm, however, they could not see the arm, only the start and target points. They estimated the position of their fingertip based solely on proprioception after their reaching movement was stopped before reaching the target. The participants stopped reaching as soon as they heard an auditory cue or were mechanically prevented from moving any further by an obstacle in their path. These reaching movements were carried out at two different speeds (fast or slow). It was assumed that additional motor commands to abort ongoing movement were required and that their magnitude was high, low, and zero, in the auditory-fast condition, the auditory-slow condition, and both the obstacle conditions, respectively. There were two main results. (1) When the participants voluntarily stopped a fast movement in response to the auditory cue (the auditory-fast condition), they showed more underestimates than in the other three conditions. This underestimate effect was positively related to movement velocity. (2) An inverted-U-shaped bias pattern as a function of movement distance was observed consistently, except in the auditory-fast condition. These findings indicate that voluntarily stopping fast ongoing movement created a negative bias in the position estimate, supporting the idea that additional motor commands or efforts to abort planned movement are involved with the position estimation system. In addition, spatially probabilistic inference and signal-dependent noise may explain the underestimate effect of aborting ongoing movement.

  20. Endurance Enhancement and High Speed Set/Reset of 50 nm Generation HfO2 Based Resistive Random Access Memory Cell by Intelligent Set/Reset Pulse Shape Optimization and Verify Scheme

    NASA Astrophysics Data System (ADS)

    Higuchi, Kazuhide; Miyaji, Kousuke; Johguchi, Koh; Takeuchi, Ken

    2012-02-01

    This paper proposes a verify-programming method for the resistive random access memory (ReRAM) cell which achieves a 50-times higher endurance and a fast set and reset compared with the conventional method. The proposed verify-programming method uses the incremental pulse width with turnback (IPWWT) for the reset and the incremental voltage with turnback (IVWT) for the set. With the combination of IPWWT reset and IVWT set, the endurance-cycle increases from 48 ×103 to 2444 ×103 cycles. Furthermore, the measured data retention-time after 20 ×103 set/reset cycles is estimated to be 10 years. Additionally, the filamentary based physical model is proposed to explain the set/reset failure mechanism with various set/reset pulse shapes. The reset pulse width and set voltage correspond to the width and length of the conductive-filament, respectively. Consequently, since the proposed IPWWT and IVWT recover set and reset failures of ReRAM cells, the endurance-cycles are improved.

  1. Rapid detection of health-care-associated bloodstream infection in critical care using multipathogen real-time polymerase chain reaction technology: a diagnostic accuracy study and systematic review.

    PubMed

    Warhurst, Geoffrey; Dunn, Graham; Chadwick, Paul; Blackwood, Bronagh; McAuley, Daniel; Perkins, Gavin D; McMullan, Ronan; Gates, Simon; Bentley, Andrew; Young, Duncan; Carlson, Gordon L; Dark, Paul

    2015-05-01

    There is growing interest in the potential utility of real-time polymerase chain reaction (PCR) in diagnosing bloodstream infection by detecting pathogen deoxyribonucleic acid (DNA) in blood samples within a few hours. SeptiFast (Roche Diagnostics GmBH, Mannheim, Germany) is a multipathogen probe-based system targeting ribosomal DNA sequences of bacteria and fungi. It detects and identifies the commonest pathogens causing bloodstream infection. As background to this study, we report a systematic review of Phase III diagnostic accuracy studies of SeptiFast, which reveals uncertainty about its likely clinical utility based on widespread evidence of deficiencies in study design and reporting with a high risk of bias. Determine the accuracy of SeptiFast real-time PCR for the detection of health-care-associated bloodstream infection, against standard microbiological culture. Prospective multicentre Phase III clinical diagnostic accuracy study using the standards for the reporting of diagnostic accuracy studies criteria. Critical care departments within NHS hospitals in the north-west of England. Adult patients requiring blood culture (BC) when developing new signs of systemic inflammation. SeptiFast real-time PCR results at species/genus level compared with microbiological culture in association with independent adjudication of infection. Metrics of diagnostic accuracy were derived including sensitivity, specificity, likelihood ratios and predictive values, with their 95% confidence intervals (CIs). Latent class analysis was used to explore the diagnostic performance of culture as a reference standard. Of 1006 new patient episodes of systemic inflammation in 853 patients, 922 (92%) met the inclusion criteria and provided sufficient information for analysis. Index test assay failure occurred on 69 (7%) occasions. Adult patients had been exposed to a median of 8 days (interquartile range 4-16 days) of hospital care, had high levels of organ support activities and recent antibiotic exposure. SeptiFast real-time PCR, when compared with culture-proven bloodstream infection at species/genus level, had better specificity (85.8%, 95% CI 83.3% to 88.1%) than sensitivity (50%, 95% CI 39.1% to 60.8%). When compared with pooled diagnostic metrics derived from our systematic review, our clinical study revealed lower test accuracy of SeptiFast real-time PCR, mainly as a result of low diagnostic sensitivity. There was a low prevalence of BC-proven pathogens in these patients (9.2%, 95% CI 7.4% to 11.2%) such that the post-test probabilities of both a positive (26.3%, 95% CI 19.8% to 33.7%) and a negative SeptiFast test (5.6%, 95% CI 4.1% to 7.4%) indicate the potential limitations of this technology in the diagnosis of bloodstream infection. However, latent class analysis indicates that BC has a low sensitivity, questioning its relevance as a reference test in this setting. Using this analysis approach, the sensitivity of the SeptiFast test was low but also appeared significantly better than BC. Blood samples identified as positive by either culture or SeptiFast real-time PCR were associated with a high probability (> 95%) of infection, indicating higher diagnostic rule-in utility than was apparent using conventional analyses of diagnostic accuracy. SeptiFast real-time PCR on blood samples may have rapid rule-in utility for the diagnosis of health-care-associated bloodstream infection but the lack of sensitivity is a significant limiting factor. Innovations aimed at improved diagnostic sensitivity of real-time PCR in this setting are urgently required. Future work recommendations include technology developments to improve the efficiency of pathogen DNA extraction and the capacity to detect a much broader range of pathogens and drug resistance genes and the application of new statistical approaches able to more reliably assess test performance in situation where the reference standard (e.g. blood culture in the setting of high antimicrobial use) is prone to error. The systematic review is registered as PROSPERO CRD42011001289. The National Institute for Health Research Health Technology Assessment programme. Professor Daniel McAuley and Professor Gavin D Perkins contributed to the systematic review through their funded roles as codirectors of the Intensive Care Foundation (UK).

  2. Fasting capillary blood glucose: an appropriate measurement in screening for diabetes and pre-diabetes in low-resource rural settings.

    PubMed

    Zhao, X; Zhao, W; Zhang, H; Li, J; Shu, Y; Li, S; Cai, L; Zhou, J; Li, Y; Hu, R

    2013-01-01

    To evaluate the efficiency of fasting capillary blood glucose (FCG) measurement as compared with fasting venous plasma glucose (FPG) measurement in screening diabetes and pre-diabetes in low-resource rural settings. In 2010, 993 participants were randomly selected from 9 villages in Yunnan province using cluster sampling method. Samples for FCG and FPG test were obtained after demographics and physical examination. The oral glucose tolerance test was performed in parallel as gold standard for diagnosis. Diagnostic capacities of the FCG measurement in predicting undiagnosed diabetes and pre-diabetes were assessed. The performance of FCG and FPG tests was compared. Fifty-seven individuals with undiagnosed diabetes and 145 subjects with pre-diabetes were detected. The concordance between FCG and FPG levels was high (r = 0.75, p < 0.001). The area under the curve (AUC) for FCG test in predicting diabetes was 0.88 [95% confidence interval (CI) 0.82-0.93] with the optimal cutoff value of 5.65 mmol/l, sensitivity of 84.2%, and specificity of 79.3%. The corresponding values in FPG tests were 0.92 (95% CI 0.88-0.97) (AUC), 6.51 mmol/l (optimal cutoff point), 82.5% (sensitivity) and 98.3% (specificity), respectively. No significant difference was found in the AUC for the two screening strategies. FCG measurement is considered to be a convenient, practicable screening method in low-resource rural communities with acceptable test properties.

  3. Sport-specific functional movement can simulate aspects of neuromuscular fatigue occurring in team sports.

    PubMed

    Wilke, Jan; Fleckenstein, Johannes; Krause, Frieder; Vogt, Lutz; Banzer, Winfried

    2016-06-01

    Fatigue protocols have been used over the years to examine muscular exhaustion. As an alternative to approaches in laboratory settings, functional agility protocols claiming to mimic the multifaceted loads of athletic activity have been proposed. This study aimed to examine the effects of a functional agility short-term fatigue protocol (FAST-FP) on neuromuscular function. Twenty-eight healthy sports students (15 males, aged 24.3 ± 2.4 years) completed the FAST-FP, which consists of four components: three counter-movement jumps (90% of individual maximum), a 20-s bout of step-ups, three bodyweight squats and an agility run. Tasks were repeated until the participants no longer achieved the required jump height in two consecutive sets. Outcomes (pre-post) encompassed subjective exhaustion (visual analogue scale [VAS]), maximum isometric voluntary force of the knee extensors (MIVF), reactive strength index (RSI), mean power frequency (MPF, measured using surface electromyography) and maximum knee range of motion (ROM). Post-intervention, VAS (+54 mm) increased significantly, while MIVF (-6.1%), RSI (-10.7%) and MPF (-4.1%) were reduced (p < 0.05). No changes were observed for ROM (p > 0.05). The FAST-FP induces small-to-moderate impairments in neuromuscular function and considerable self-perceived fatigue. Current evidence on exhaustion developing in team sports suggests that this magnitude of fatigue is similar. The protocol might thus be valuable in the evaluation of treatments counteracting post-match fatigue in team sports.

  4. Investigation of three-dimensional localisation of radioactive sources using a fast organic liquid scintillator detector

    NASA Astrophysics Data System (ADS)

    Gamage, K. A. A.; Joyce, M. J.; Taylor, G. C.

    2013-04-01

    In this paper we discuss the possibility of locating radioactive sources in space using a scanning-based method, relative to the three-dimensional location of the detector. The scanning system comprises an organic liquid scintillator detector, a tungsten collimator and an adjustable equatorial mount. The detector output is connected to a bespoke fast digitiser (Hybrid Instruments Ltd., UK) which streams digital samples to a personal computer. A radioactive source has been attached to a vertical wall and the data have been collected in two stages. In the first case, the scanning system was placed a couple of metres away from the wall and in the second case it moved few centimetres from the previous location, parallel to the wall. In each case data were collected from a grid of measurement points (set of azimuth angles for set of elevation angles) which covered the source on the wall. The discrimination of fast neutrons and gamma rays, detected by the organic liquid scintillator detector, is carried out on the basis of pulse gradient analysis. Images are then produced in terms of the angular distribution of events for total counts, gamma rays and neutrons for both cases. The three-dimensional location of the neutron source can be obtained by considering the relative separation of the centres of the corresponding images of angular distribution of events. The measurements have been made at the National Physical Laboratory, Teddington, Middlesex, UK.

  5. Cognitive effort is modulated outside of the explicit awareness of conflict frequency: Evidence from pupillometry.

    PubMed

    Diede, Nathaniel T; Bugg, Julie M

    2017-05-01

    Classic theories of cognitive control conceptualized controlled processes as slow, strategic, and willful, with automatic processes being fast and effortless. The context-specific proportion compatibility (CSPC) effect, the reduction in the compatibility effect in a context (e.g., location) associated with a high relative to low likelihood of conflict, challenged classic theories by demonstrating fast and flexible control that appears to operate outside of conscious awareness. Two theoretical questions yet to be addressed are whether the CSPC effect is accompanied by context-dependent variation in effort, and whether the exertion of effort depends on explicit awareness of context-specific task demands. To address these questions, pupil diameter was measured during a CSPC paradigm. Stimuli were randomly presented in either a mostly compatible location or a mostly incompatible location. Replicating prior research, the CSPC effect was found. The novel finding was that pupil diameter was greater in the mostly incompatible location compared to the mostly compatible location, despite participants' lack of awareness of context-specific task demands. Additionally, this difference occurred regardless of trial type or a preceding switch in location. These patterns support the view that context (location) dictates selection of optimal attentional settings in the CSPC paradigm, and varying levels of effort and performance accompany these settings. Theoretically, these patterns imply that cognitive control may operate fast, flexibly, and outside of awareness, but not effortlessly. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  6. Fast Dating Using Least-Squares Criteria and Algorithms.

    PubMed

    To, Thu-Hien; Jung, Matthieu; Lycett, Samantha; Gascuel, Olivier

    2016-01-01

    Phylogenies provide a useful way to understand the evolutionary history of genetic samples, and data sets with more than a thousand taxa are becoming increasingly common, notably with viruses (e.g., human immunodeficiency virus (HIV)). Dating ancestral events is one of the first, essential goals with such data. However, current sophisticated probabilistic approaches struggle to handle data sets of this size. Here, we present very fast dating algorithms, based on a Gaussian model closely related to the Langley-Fitch molecular-clock model. We show that this model is robust to uncorrelated violations of the molecular clock. Our algorithms apply to serial data, where the tips of the tree have been sampled through times. They estimate the substitution rate and the dates of all ancestral nodes. When the input tree is unrooted, they can provide an estimate for the root position, thus representing a new, practical alternative to the standard rooting methods (e.g., midpoint). Our algorithms exploit the tree (recursive) structure of the problem at hand, and the close relationships between least-squares and linear algebra. We distinguish between an unconstrained setting and the case where the temporal precedence constraint (i.e., an ancestral node must be older that its daughter nodes) is accounted for. With rooted trees, the former is solved using linear algebra in linear computing time (i.e., proportional to the number of taxa), while the resolution of the latter, constrained setting, is based on an active-set method that runs in nearly linear time. With unrooted trees the computing time becomes (nearly) quadratic (i.e., proportional to the square of the number of taxa). In all cases, very large input trees (>10,000 taxa) can easily be processed and transformed into time-scaled trees. We compare these algorithms to standard methods (root-to-tip, r8s version of Langley-Fitch method, and BEAST). Using simulated data, we show that their estimation accuracy is similar to that of the most sophisticated methods, while their computing time is much faster. We apply these algorithms on a large data set comprising 1194 strains of Influenza virus from the pdm09 H1N1 Human pandemic. Again the results show that these algorithms provide a very fast alternative with results similar to those of other computer programs. These algorithms are implemented in the LSD software (least-squares dating), which can be downloaded from http://www.atgc-montpellier.fr/LSD/, along with all our data sets and detailed results. An Online Appendix, providing additional algorithm descriptions, tables, and figures can be found in the Supplementary Material available on Dryad at http://dx.doi.org/10.5061/dryad.968t3. © The Author(s) 2015. Published by Oxford University Press, on behalf of the Society of Systematic Biologists.

  7. Fast Dating Using Least-Squares Criteria and Algorithms

    PubMed Central

    To, Thu-Hien; Jung, Matthieu; Lycett, Samantha; Gascuel, Olivier

    2016-01-01

    Phylogenies provide a useful way to understand the evolutionary history of genetic samples, and data sets with more than a thousand taxa are becoming increasingly common, notably with viruses (e.g., human immunodeficiency virus (HIV)). Dating ancestral events is one of the first, essential goals with such data. However, current sophisticated probabilistic approaches struggle to handle data sets of this size. Here, we present very fast dating algorithms, based on a Gaussian model closely related to the Langley–Fitch molecular-clock model. We show that this model is robust to uncorrelated violations of the molecular clock. Our algorithms apply to serial data, where the tips of the tree have been sampled through times. They estimate the substitution rate and the dates of all ancestral nodes. When the input tree is unrooted, they can provide an estimate for the root position, thus representing a new, practical alternative to the standard rooting methods (e.g., midpoint). Our algorithms exploit the tree (recursive) structure of the problem at hand, and the close relationships between least-squares and linear algebra. We distinguish between an unconstrained setting and the case where the temporal precedence constraint (i.e., an ancestral node must be older that its daughter nodes) is accounted for. With rooted trees, the former is solved using linear algebra in linear computing time (i.e., proportional to the number of taxa), while the resolution of the latter, constrained setting, is based on an active-set method that runs in nearly linear time. With unrooted trees the computing time becomes (nearly) quadratic (i.e., proportional to the square of the number of taxa). In all cases, very large input trees (>10,000 taxa) can easily be processed and transformed into time-scaled trees. We compare these algorithms to standard methods (root-to-tip, r8s version of Langley–Fitch method, and BEAST). Using simulated data, we show that their estimation accuracy is similar to that of the most sophisticated methods, while their computing time is much faster. We apply these algorithms on a large data set comprising 1194 strains of Influenza virus from the pdm09 H1N1 Human pandemic. Again the results show that these algorithms provide a very fast alternative with results similar to those of other computer programs. These algorithms are implemented in the LSD software (least-squares dating), which can be downloaded from http://www.atgc-montpellier.fr/LSD/, along with all our data sets and detailed results. An Online Appendix, providing additional algorithm descriptions, tables, and figures can be found in the Supplementary Material available on Dryad at http://dx.doi.org/10.5061/dryad.968t3. PMID:26424727

  8. Diurnal Variation of Hormonal and Lipid Biomarkers in a Molecular Epidemiology-Like Setting.

    PubMed

    van Kerkhof, Linda W M; Van Dycke, Kirsten C G; Jansen, Eugene H J M; Beekhof, Piet K; van Oostrom, Conny T M; Ruskovska, Tatjana; Velickova, Nevenka; Kamcev, Nikola; Pennings, Jeroen L A; van Steeg, Harry; Rodenburg, Wendy

    2015-01-01

    Many molecular epidemiology studies focusing on high prevalent diseases, such as metabolic disorders and cancer, investigate metabolic and hormonal markers. In general, sampling for these markers can occur at any time-point during the day or after an overnight fast. However, environmental factors, such as light exposure and food intake might affect the levels of these markers, since they provide input for the internal time-keeping system. When diurnal variation is larger than the inter-individual variation, time of day should be taken into account. Importantly, heterogeneity in diurnal variation and disturbance of circadian rhythms among a study population might increasingly occur as a result of our increasing 24/7 economy and related variation in exposure to environmental factors (such as light and food). The aim of the present study was to determine whether a set of often used biomarkers shows diurnal variation in a setting resembling large molecular epidemiology studies, i.e., non-fasted and limited control possibilities for other environmental influences. We show that markers for which diurnal variation is not an issue are adrenocorticotropic hormone, follicle stimulating hormone, estradiol and high-density lipoprotein. For all other tested markers diurnal variation was observed in at least one gender (cholesterol, cortisol, dehydroepiandrosterone sulfate, free fatty acids, low-density lipoprotein, luteinizing hormone, prolactin, progesterone, testosterone, triglycerides, total triiodothyronine and thyroid-stimulating hormone) or could not reliably be detected (human growth hormone). Thus, studies investigating these markers should take diurnal variation into account, for which we provide some options. Furthermore, our study indicates the need for investigating diurnal variation (in literature or experimentally) before setting up studies measuring markers in routine and controlled settings, especially since time-of-day likely matters for many more markers than the ones investigated in the present study.

  9. Fast structure similarity searches among protein models: efficient clustering of protein fragments

    PubMed Central

    2012-01-01

    Background For many predictive applications a large number of models is generated and later clustered in subsets based on structure similarity. In most clustering algorithms an all-vs-all root mean square deviation (RMSD) comparison is performed. Most of the time is typically spent on comparison of non-similar structures. For sets with more than, say, 10,000 models this procedure is very time-consuming and alternative faster algorithms, restricting comparisons only to most similar structures would be useful. Results We exploit the inverse triangle inequality on the RMSD between two structures given the RMSDs with a third structure. The lower bound on RMSD may be used, when restricting the search of similarity to a reasonably low RMSD threshold value, to speed up similarity searches significantly. Tests are performed on large sets of decoys which are widely used as test cases for predictive methods, with a speed-up of up to 100 times with respect to all-vs-all comparison depending on the set and parameters used. Sample applications are shown. Conclusions The algorithm presented here allows fast comparison of large data sets of structures with limited memory requirements. As an example of application we present clustering of more than 100000 fragments of length 5 from the top500H dataset into few hundred representative fragments. A more realistic scenario is provided by the search of similarity within the very large decoy sets used for the tests. Other applications regard filtering nearly-indentical conformation in selected CASP9 datasets and clustering molecular dynamics snapshots. Availability A linux executable and a Perl script with examples are given in the supplementary material (Additional file 1). The source code is available upon request from the authors. PMID:22642815

  10. Fast analytic solver of rational Bethe equations

    NASA Astrophysics Data System (ADS)

    Marboe, C.; Volin, D.

    2017-05-01

    In this note we propose an approach for a fast analytic determination of all possible sets of Bethe roots corresponding to eigenstates of rational {GL}({N}\\vert {M}) integrable spin chains of given not too large length, in terms of Baxter Q-functions. We observe that all exceptional solutions, if any, are automatically correctly accounted. The key intuition behind the approach is that the equations on the Q-functions are determined solely by the Young diagram, and not by the choice of the rank of the {GL} symmetry. Hence we can choose arbitrary {N} and {M} that accommodate the desired representation. Then we consider all distinguished Q-functions at once, not only those following a certain Kac-Dynkin path.

  11. A robust and fast active contour model for image segmentation with intensity inhomogeneity

    NASA Astrophysics Data System (ADS)

    Ding, Keyan; Weng, Guirong

    2018-04-01

    In this paper, a robust and fast active contour model is proposed for image segmentation in the presence of intensity inhomogeneity. By introducing the local image intensities fitting functions before the evolution of curve, the proposed model can effectively segment images with intensity inhomogeneity. And the computation cost is low because the fitting functions do not need to be updated in each iteration. Experiments have shown that the proposed model has a higher segmentation efficiency compared to some well-known active contour models based on local region fitting energy. In addition, the proposed model is robust to initialization, which allows the initial level set function to be a small constant function.

  12. Optical Design And Analysis Of Carbon Dioxide Laser Fusion Systems Using Interferometry And Fast Fourier Transform Techniques

    NASA Astrophysics Data System (ADS)

    Viswanathan, V. K.

    1980-11-01

    The optical design and analysis of the LASL carbon dioxide laser fusion systems required the use of techniques that are quite different from the currently used method in conventional optical design problems. The necessity for this is explored and the method that has been successfully used at Los Alamos to understand these systems is discussed with examples. This method involves characterization of the various optical components in their mounts by a Zernike polynomial set and using fast Fourier transform techniques to propagate the beam, taking diffraction and other nonlinear effects that occur in these types of systems into account. The various programs used for analysis are briefly discussed.

  13. Shortcuts to adiabatic passage for fast generation of Greenberger-Horne-Zeilinger states by transitionless quantum driving.

    PubMed

    Chen, Ye-Hong; Xia, Yan; Song, Jie; Chen, Qing-Qin

    2015-10-28

    Berry's approach on "transitionless quantum driving" shows how to set a Hamiltonian which drives the dynamics of a system along instantaneous eigenstates of a reference Hamiltonian to reproduce the same final result of an adiabatic process in a shorter time. In this paper, motivated by transitionless quantum driving, we construct shortcuts to adiabatic passage in a three-atom system to create the Greenberger-Horne-Zeilinger states with the help of quantum Zeno dynamics and of non-resonant lasers. The influence of various decoherence processes is discussed by numerical simulation and the result proves that the scheme is fast and robust against decoherence and operational imperfection.

  14. Classification of large-sized hyperspectral imagery using fast machine learning algorithms

    NASA Astrophysics Data System (ADS)

    Xia, Junshi; Yokoya, Naoto; Iwasaki, Akira

    2017-07-01

    We present a framework of fast machine learning algorithms in the context of large-sized hyperspectral images classification from the theoretical to a practical viewpoint. In particular, we assess the performance of random forest (RF), rotation forest (RoF), and extreme learning machine (ELM) and the ensembles of RF and ELM. These classifiers are applied to two large-sized hyperspectral images and compared to the support vector machines. To give the quantitative analysis, we pay attention to comparing these methods when working with high input dimensions and a limited/sufficient training set. Moreover, other important issues such as the computational cost and robustness against the noise are also discussed.

  15. Singer product apertures-A coded aperture system with a fast decoding algorithm

    NASA Astrophysics Data System (ADS)

    Byard, Kevin; Shutler, Paul M. E.

    2017-06-01

    A new type of coded aperture configuration that enables fast decoding of the coded aperture shadowgram data is presented. Based on the products of incidence vectors generated from the Singer difference sets, we call these Singer product apertures. For a range of aperture dimensions, we compare experimentally the performance of three decoding methods: standard decoding, induction decoding and direct vector decoding. In all cases the induction and direct vector methods are several orders of magnitude faster than the standard method, with direct vector decoding being significantly faster than induction decoding. For apertures of the same dimensions the increase in speed offered by direct vector decoding over induction decoding is better for lower throughput apertures.

  16. An improved VSS NLMS algorithm for active noise cancellation

    NASA Astrophysics Data System (ADS)

    Sun, Yunzhuo; Wang, Mingjiang; Han, Yufei; Zhang, Congyan

    2017-08-01

    In this paper, an improved variable step size NLMS algorithm is proposed. NLMS has fast convergence rate and low steady state error compared to other traditional adaptive filtering algorithm. But there is a contradiction between the convergence speed and steady state error that affect the performance of the NLMS algorithm. Now, we propose a new variable step size NLMS algorithm. It dynamically changes the step size according to current error and iteration times. The proposed algorithm has simple formulation and easily setting parameters, and effectively solves the contradiction in NLMS. The simulation results show that the proposed algorithm has a good tracking ability, fast convergence rate and low steady state error simultaneously.

  17. FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool.

    PubMed

    Brown, Joseph; Pirrung, Meg; McCue, Lee Ann

    2017-06-09

    FQC is software that facilitates quality control of FASTQ files by carrying out a QC protocol using FastQC, parsing results, and aggregating quality metrics into an interactive dashboard designed to richly summarize individual sequencing runs. The dashboard groups samples in dropdowns for navigation among the data sets, utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data. FQC is implemented in Python 3 and Javascript, and is maintained under an MIT license. Documentation and source code is available at: https://github.com/pnnl/fqc . joseph.brown@pnnl.gov. © The Author(s) 2017. Published by Oxford University Press.

  18. FAST TRACK COMMUNICATION: Weyl law for fat fractals

    NASA Astrophysics Data System (ADS)

    Spina, María E.; García-Mata, Ignacio; Saraceno, Marcos

    2010-10-01

    It has been conjectured that for a class of piecewise linear maps the closure of the set of images of the discontinuity has the structure of a fat fractal, that is, a fractal with positive measure. An example of such maps is the sawtooth map in the elliptic regime. In this work we analyze this problem quantum mechanically in the semiclassical regime. We find that the fraction of states localized on the unstable set satisfies a modified fractal Weyl law, where the exponent is given by the exterior dimension of the fat fractal.

  19. FindGDPs: fast identification of primers for labeling microbial transcriptomes for DNA microarray analysis

    PubMed Central

    Blick, Robert J.; Revel, Andrew T.; Hansen, Eric J.

    2008-01-01

    Summary FindGDPs is a program that uses a greedy algorithm to quickly identify a set of genome-directed primers that specifically anneal to all of the open reading frames in a genome and that do not exhibit full-length complementarity to the members of another user-supplied set of nucleotide sequences. Availability The program code is distributed under the GNU General Public License at http://www8.utsouthwestern.edu/utsw/cda/dept131456/files/159331.html Contact eric.hansen@utsouthwestern.edu PMID:15593406

  20. Simulation of Voltage SET Operation in Phase-Change Random Access Memories with Heater Addition and Ring-Type Contactor for Low-Power Consumption by Finite Element Modeling

    NASA Astrophysics Data System (ADS)

    Gong, Yue-Feng; Song, Zhi-Tang; Ling, Yun; Liu, Yan; Li, Yi-Jin

    2010-06-01

    A three-dimensional finite element model for phase change random access memory is established to simulate electric, thermal and phase state distribution during (SET) operation. The model is applied to simulate the SET behaviors of the heater addition structure (HS) and the ring-type contact in the bottom electrode (RIB) structure. The simulation results indicate that the small bottom electrode contactor (BEC) is beneficial for heat efficiency and reliability in the HS cell, and the bottom electrode contactor with size Fx = 80 nm is a good choice for the RIB cell. Also shown is that the appropriate SET pulse time is 100 ns for the low power consumption and fast operation.

  1. Dietary intake of palmitate and oleate has broad impact on systemic and tissue lipid profiles in humans.

    PubMed

    Kien, C Lawrence; Bunn, Janice Y; Stevens, Robert; Bain, James; Ikayeva, Olga; Crain, Karen; Koves, Timothy R; Muoio, Deborah M

    2014-03-01

    Epidemiologic evidence has suggested that diets with a high ratio of palmitic acid (PA) to oleic acid (OA) increase risk of cardiovascular disease (CVD). To gain additional insights into the relative effect of dietary fatty acids and their metabolism on CVD risk, we sought to identify a metabolomic signature that tracks with diet-induced changes in blood lipid concentrations and whole-body fat oxidation. We applied comprehensive metabolomic profiling tools to biological specimens collected from 18 healthy adults enrolled in a crossover trial that compared a 3-wk high-palmitic acid (HPA) with a low-palmitic acid and high-oleic acid (HOA) diet. A principal components analysis of the data set including 329 variables measured in 15 subjects in the fasted state identified one factor, the principal components analysis factor in the fasted state (PCF1-Fasted), which was heavily weighted by the PA:OA ratio of serum and muscle lipids, that was affected by diet (P < 0.0001; HPA greater than HOA). One other factor, the additional principal components analysis factor in the fasted state (PCF2-Fasted), reflected a wide range of acylcarnitines and was affected by diet in women only (P = 0.0198; HPA greater than HOA). HOA lowered the ratio of serum low-density lipoprotein to high-density lipoprotein (LDL:HDL) in men and women, and adjustment for the PCF1-Fasted abolished the effect. In women only, adjustment for the PCF2-Fasted eliminated the HOA-diet effect on serum total- and LDL-cholesterol concentrations. The respiratory exchange ratio in the fasted state was lower with the HPA diet (P = 0.04), and the diet effect was eliminated after adjustment for the PCF1-Fasted. The messenger RNA expression of the cholesterol regulatory gene insulin-induced gene-1 was higher with the HOA diet (P = 0.008). These results suggest that replacing dietary PA with OA reduces the blood LDL concentration and whole-body fat oxidation by modifying the saturation index of circulating and tissue lipids. In women, these effects are also associated with a higher production and accumulation of acylcarnitines, possibly reflecting a shift in fat catabolism.

  2. Private Higher Education in India: A Study of Two Private Universities

    ERIC Educational Resources Information Center

    Angom, Sangeeta

    2015-01-01

    The Private higher education sector is growing fast in many settings, including India, and there are variations at the national level. Privatization of higher education in India has been the result of changes in the economic policy towards liberalization and privatization by the Government of India. Till 1980, higher education sector was…

  3. In Canada: Litigating Literacy

    ERIC Educational Resources Information Center

    Robertson, Heather-jane

    2004-01-01

    While Canadians tend to consider the American system to be overly litigious, they are catching up fast. Their own domestic set of plaintiffs is suing the agents of obesity and pollution, but actions pertaining to education seem to be spiking as well. A few of these cases are trivial. This morning's local newspaper reports that a judge has ruled…

  4. What Makes Counsellors Working in Primary Care Distinct from Counsellors Working in Other Settings?

    ERIC Educational Resources Information Center

    Hudson-Allez, Glyn

    2000-01-01

    Counseling in primary care can be considered a fast-evolving profession that is distinct from counseling in the private sector. Differences in counselor roles, specifically confidentiality ethics and working hours, are discussed. Referrals and attrition are also discussed. The distinctiveness of primary care counseling versus working in more…

  5. A Fast 4-D TEM System for UXO Characterization

    DTIC Science & Technology

    2003-07-30

    responses for a small conductive and permeable sphere. Magnetic permeability is the curve parameter. Figure 2.10: Compass/ Tiltmeter package...each TCM2 record. The DOS clock on the HP200LX was manually set to UTC each day using the UTC time displayed on the Figure 2.10: Compass/ Tiltmeter

  6. Food, Aid, and Education in East Africa: Repackaging the Conversation

    ERIC Educational Resources Information Center

    Stambach, Amy

    2016-01-01

    This paper examines students' food perspectives in three rapidly diversifying contemporary contexts: a university setting in Kigali, Rwanda where students help to prepare Chinese dumplings; a school garden and canteen in Nairobi, Kenya where students jostle for bowls of beans and rice; and a fast-food restaurant in Dar es Salaam, Tanzania, where…

  7. Cocaine, Glamorous Status Symbol of the 'Jet Set,' Is Fast Becoming Many Students' Drug of Choice.

    ERIC Educational Resources Information Center

    Greene, Elizabeth

    1985-01-01

    Cocaine, the highly addictive substance, is being used by alarming numbers of undergraduates, and many are selling it on their campuses to support their own habits. A questionnaire for students who might be in trouble with cocaine and don't know it is provided. (MLW)

  8. Health Assessment Data Collection as Part of a College Wellness Course

    ERIC Educational Resources Information Center

    Kruger, Laura B.; Roeder, Linda D.; Brubaker, Kenneth D., Jr.

    2014-01-01

    The purpose of this investigation was to examine the comprehensive data set of health of college students regarding cardiovascular risk factors, specifically body mass index (BMI), blood pressure (BP), fasting lipid profile, and glucose and to compare results to similar studies. Results were also used to educate individual students regarding their…

  9. Online Learning: E-Learning Fast, Cheap, and Good

    ERIC Educational Resources Information Center

    Piskurich, George M.

    2006-01-01

    There is a variation of e-learning, used mainly in academic settings, that can be a valuable intervention tool for the performance technologist. It is often referred to as online learning. In the performance improvement field, this term is often used interchangeably with synchronous e-learning, but there are some major differences between these…

  10. Fast and Accurate Detection of Spread Source in Large Complex Networks

    DTIC Science & Technology

    the patient one in epidemics, or source of rumor spreading in social network. Pinto, Thiran and Vetterli introduced an algorithm (PTVA) to solve the...important case of this problem in which a limited set of nodes act as observers and report times at which the spread reached them. PTVA uses all

  11. An Analysis of the Structure and Evolution of Networks

    ERIC Educational Resources Information Center

    Hua, Guangying

    2011-01-01

    As network research receives more and more attention from both academic researchers and practitioners, network analysis has become a fast growing field attracting many researchers from diverse fields such as physics, computer science, and sociology. This dissertation provides a review of theory and research on different real data sets from the…

  12. On Your Mark! Get Set! Go!

    ERIC Educational Resources Information Center

    Rowland, Veronica

    2006-01-01

    This article describes how second- and third-grade students joined their teacher, Mary Ann McTiernan, a marathon runner from Cape Town, South Africa, in a one-mile run every Thursday morning while she was training. Mary Ann's students had been asking, "Where do you run?" "How far do you go?" "How fast can you run?"…

  13. Views of Student Nurses on Caring and Technology in Nursing

    ERIC Educational Resources Information Center

    Brodell, Elizabeth Becky

    2009-01-01

    Nurses entering the workforce are faced with many challenges, but today the multiple demands of patient care are complicated by a nurse's need to keep abreast of fast-changing technology. This research is universally relevant to nursing practice in educational settings and practice areas because nursing education needs to develop strategies to…

  14. PARENT-COUNSELOR CONTACTS IN A UNIVERSITY SETTING--INCIDENTAL OR INCREMENTAL.

    ERIC Educational Resources Information Center

    MILLS, DAVID H.

    UNDERGRADUATE STUDENTS TODAY ARE MOVING TOWARD INCREASED AUTONOMY. THE UNIVERSITIES ARE RESPONDING BY BECOMING LESS PARENTAL, ALTHOUGH NOT AS FAST AS STUDENTS WOULD LIKE. DESPITE THEIR EMANCIPATION FROM PARENTS AND PARENT-LIKE AUTHORITY, STUDENTS STILL TEND TO SEE THE COUNSELOR AS A PARENTAL FIGURE. THE COUNSELOR MUST THEREFORE HELP THE STUDENT…

  15. Linear Vector Quantisation and Uniform Circular Arrays based decoupled two-dimensional angle of arrival estimation

    NASA Astrophysics Data System (ADS)

    Ndaw, Joseph D.; Faye, Andre; Maïga, Amadou S.

    2017-05-01

    Artificial neural networks (ANN)-based models are efficient ways of source localisation. However very large training sets are needed to precisely estimate two-dimensional Direction of arrival (2D-DOA) with ANN models. In this paper we present a fast artificial neural network approach for 2D-DOA estimation with reduced training sets sizes. We exploit the symmetry properties of Uniform Circular Arrays (UCA) to build two different datasets for elevation and azimuth angles. Linear Vector Quantisation (LVQ) neural networks are then sequentially trained on each dataset to separately estimate elevation and azimuth angles. A multilevel training process is applied to further reduce the training sets sizes.

  16. Neural Network Prediction of New Aircraft Design Coefficients

    NASA Technical Reports Server (NTRS)

    Norgaard, Magnus; Jorgensen, Charles C.; Ross, James C.

    1997-01-01

    This paper discusses a neural network tool for more effective aircraft design evaluations during wind tunnel tests. Using a hybrid neural network optimization method, we have produced fast and reliable predictions of aerodynamical coefficients, found optimal flap settings, and flap schedules. For validation, the tool was tested on a 55% scale model of the USAF/NASA Subsonic High Alpha Research Concept aircraft (SHARC). Four different networks were trained to predict coefficients of lift, drag, moment of inertia, and lift drag ratio (C(sub L), C(sub D), C(sub M), and L/D) from angle of attack and flap settings. The latter network was then used to determine an overall optimal flap setting and for finding optimal flap schedules.

  17. A numerical spectral approach to solve the dislocation density transport equation

    NASA Astrophysics Data System (ADS)

    Djaka, K. S.; Taupin, V.; Berbenni, S.; Fressengeas, C.

    2015-09-01

    A numerical spectral approach is developed to solve in a fast, stable and accurate fashion, the quasi-linear hyperbolic transport equation governing the spatio-temporal evolution of the dislocation density tensor in the mechanics of dislocation fields. The approach relies on using the Fast Fourier Transform algorithm. Low-pass spectral filters are employed to control both the high frequency Gibbs oscillations inherent to the Fourier method and the fast-growing numerical instabilities resulting from the hyperbolic nature of the transport equation. The numerical scheme is validated by comparison with an exact solution in the 1D case corresponding to dislocation dipole annihilation. The expansion and annihilation of dislocation loops in 2D and 3D settings are also produced and compared with finite element approximations. The spectral solutions are shown to be stable, more accurate for low Courant numbers and much less computation time-consuming than the finite element technique based on an explicit Galerkin-least squares scheme.

  18. Optical detection of three modes of endocytosis at hippocampal synapses

    PubMed Central

    Chanaday, Natali L

    2018-01-01

    Coupling of synaptic vesicle fusion and retrieval constitutes a core mechanism ensuring maintenance of presynaptic function. Recent studies using fast-freeze electron microscopy and capacitance measurements reported an ultrafast mode of endocytosis operating at physiological temperatures. Here, using rat hippocampal neurons, we optically monitored single synaptic vesicle endocytosis with high time resolution using the vesicular glutamate transporter, synaptophysin and the V0a1 subunit of the vacuolar ATPase as probes. In this setting, we could distinguish three components of retrieval operating at ultrafast (~150–250 ms, ~20% of events), fast (~5–12 s, ~40% of events) and ultraslow speeds (>20 s, ~40% of events). While increasing Ca2+ slowed the fast events, increasing temperature accelerated their time course. In contrast, the kinetics of ultrafast events were only mildly affected by these manipulations. These results suggest that synaptic vesicle proteins can be retrieved with ultrafast kinetics, although a majority of evoked fusion events are coupled to slower retrieval mechanisms. PMID:29683423

  19. Anisotropic Rayleigh-wave phase velocities beneath northern Vietnam

    NASA Astrophysics Data System (ADS)

    Legendre, Cédric P.; Zhao, Li; Huang, Win-Gee; Huang, Bor-Shouh

    2015-02-01

    We explore the Rayleigh-wave phase-velocity structure beneath northern Vietnam over a broad period range of 5 to 250 s. We use the two-stations technique to derive the dispersion curves from the waveforms of 798 teleseismic events recoded by a set of 23 broadband seismic stations deployed in northern Vietnam. These dispersion curves are then inverted for both isotropic and azimuthally anisotropic Rayleigh-wave phase-velocity maps in the frequency range of 10 to 50 s. Main findings include a crustal expression of the Red River Shear Zone and the Song Ma Fault. Northern Vietnam displays a northeast/southwest dichotomy in the lithosphere with fast velocities beneath the South China Block and slow velocities beneath the Simao Block and between the Red River Fault and the Song Da Fault. The anisotropy in the region is relatively simple, with a high amplitude and fast directions parallel to the Red River Shear Zone in the western part. In the eastern part, the amplitudes are generally smaller and the fast axis displays more variations with periods.

  20. Chlamydia trachomatis infection: the efficacy and safety of a fast-track referral and treatment system.

    PubMed

    Sethupathi, M; Blackwell, A

    2009-03-01

    We introduced a Nurse/Health Advisor-led fast-track service for treating patients diagnosed with chlamydia outside a genitourinary medicine setting and contacts of chlamydia/non-specific urethritis/cervicitis wherever diagnosed. Asymptomatic patients were treated without initial testing and asked to return for full screening at four to six weeks. We assessed the efficacy and safety of the system and need for follow-up after treatment. Case-notes of 226 patients (121 men and 105 women) were analysed, of whom 140 attended follow-up. With the exception of one case of gonorrhoea, no other serious sexually transmitted infection was detected. Twenty-seven (19.2%) patients were re-treated for either chlamydia (six patients, 4.4%) or non-specific genital infection or because of having unprotected intercourse with untreated or partially treated partners. We conclude that in our relatively low-risk population, our fast-track service is safe and effective. Test of cure for chlamydia seems essential because of the high percentage of patients requiring re-treatment.

  1. SDSS-IV MaNGA: a distinct mass distribution explored in slow-rotating early-type galaxies

    NASA Astrophysics Data System (ADS)

    Rong, Yu; Li, Hongyu; Wang, Jie; Gao, Liang; Li, Ran; Ge, Junqiang; Jing, Yingjie; Pan, Jun; Fernández-Trincado, J. G.; Valenzuela, Octavio; Ortíz, Erik Aquino

    2018-06-01

    We study the radial acceleration relation (RAR) for early-type galaxies (ETGs) in the SDSS MaNGA MPL5 data set. The complete ETG sample show a slightly offset RAR from the relation reported by McGaugh et al. (2016) at the low-acceleration end; we find that the deviation is due to the fact that the slow rotators show a systematically higher acceleration relation than the McGaugh's RAR, while the fast rotators show a consistent acceleration relation to McGaugh's RAR. There is a 1σ significant difference between the acceleration relations of the fast and slow rotators, suggesting that the acceleration relation correlates with the galactic spins, and that the slow rotators may have a different mass distribution compared with fast rotators and late-type galaxies. We suspect that the acceleration relation deviation of slow rotators may be attributed to more galaxy merger events, which would disrupt the original spins and correlated distributions of baryons and dark matter orbits in galaxies.

  2. Coupling of Fast and Slow Modes in the Reaction Pathway of the Minimal Hammerhead Ribozyme Cleavage

    PubMed Central

    Radhakrishnan, Ravi

    2007-01-01

    By employing classical molecular dynamics, correlation analysis of coupling between slow and fast dynamical modes, and free energy (umbrella) sampling using classical as well as mixed quantum mechanics molecular mechanics force fields, we uncover a possible pathway for phosphoryl transfer in the self-cleaving reaction of the minimal hammerhead ribozyme. The significance of this pathway is that it initiates from the minimal hammerhead crystal structure and describes the reaction landscape as a conformational rearrangement followed by a covalent transformation. The delineated mechanism is catalyzed by two metal (Mg2+) ions, proceeds via an in-line-attack by CYT 17 O2′ on the scissile phosphorous (ADE 1.1 P), and is therefore consistent with the experimentally observed inversion configuration. According to the delineated mechanism, the coupling between slow modes involving the hammerhead backbone with fast modes in the cleavage site appears to be crucial for setting up the in-line nucleophilic attack. PMID:17545240

  3. An Annotation Agnostic Algorithm for Detecting Nascent RNA Transcripts in GRO-Seq.

    PubMed

    Azofeifa, Joseph G; Allen, Mary A; Lladser, Manuel E; Dowell, Robin D

    2017-01-01

    We present a fast and simple algorithm to detect nascent RNA transcription in global nuclear run-on sequencing (GRO-seq). GRO-seq is a relatively new protocol that captures nascent transcripts from actively engaged polymerase, providing a direct read-out on bona fide transcription. Most traditional assays, such as RNA-seq, measure steady state RNA levels which are affected by transcription, post-transcriptional processing, and RNA stability. GRO-seq data, however, presents unique analysis challenges that are only beginning to be addressed. Here, we describe a new algorithm, Fast Read Stitcher (FStitch), that takes advantage of two popular machine-learning techniques, hidden Markov models and logistic regression, to classify which regions of the genome are transcribed. Given a small user-defined training set, our algorithm is accurate, robust to varying read depth, annotation agnostic, and fast. Analysis of GRO-seq data without a priori need for annotation uncovers surprising new insights into several aspects of the transcription process.

  4. Comparing SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout

    NASA Astrophysics Data System (ADS)

    England, Troy; Curry, Matthew; Carr, Stephen; Mounce, Andrew; Jock, Ryan; Sharma, Peter; Bureau-Oxton, Chloe; Rudolph, Martin; Hardin, Terry; Carroll, Malcolm

    Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will compare two amplifiers based on single-transistor circuits implemented with silicon germanium heterojunction bipolar transistors. Both amplifiers provide gain at low power levels, but the dynamics of each circuit vary significantly. We will explore the gain mechanisms, linearity, and noise of each circuit and explain the situations in which each amplifier is best used. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000.

  5. Weak rotating flow disturbances in a centrifugal compressor with a vaneless diffuser

    NASA Technical Reports Server (NTRS)

    Moore, F. K.

    1988-01-01

    A theory is presented to predict the occurrence of weak rotating waves in a centrifugal compression system with a vaneless diffuser. As in a previous study of axial systems, an undisturbed performance characteristic is assumed known. Following an inviscid analysis of the diffuser flow, conditions for a neutral rotating disturbance are found. The solution is shown to have two branches; one with fast rotation, the other with very slow rotation. The slow branch includes a dense set of resonant solutions. The resonance is a feature of the diffuser flow, and therefore such disturbances must be expected at the various resonant flow coefficients regardless of the compressor characteristic. Slow solutions seem limited to flow coefficients less than about 0.3, where third and fourth harmonics appear. Fast waves seem limited to a first harmonic. These fast and slow waves are described, and effects of diffuser-wall convergence, backward blade angles, and partial recovery of exit velocity head are assessed.

  6. Coherent curvature radiation and fast radio bursts

    NASA Astrophysics Data System (ADS)

    Ghisellini, Gabriele; Locatelli, Nicola

    2018-06-01

    Fast radio bursts are extragalactic radio transient events lasting a few milliseconds with a Jy flux at 1 GHz. We propose that these properties suggest a neutron star progenitor, and focus on coherent curvature radiation as the radiation mechanism. We study for which sets of parameters the emission can fulfil the observational constraints. Even if the emission is coherent, we find that self-absorption can limit the produced luminosities at low radio frequencies and that an efficient re-acceleration process is needed to balance the dramatic energy losses of the emitting particles. Self-absorption limits the luminosities at low radio frequency, while coherence favours steep optically thin spectra. Furthermore, the magnetic geometry must have a high degree of order to obtain coherent curvature emission. Particles emit photons along their velocity vectors, thereby greatly reducing the inverse Compton mechanism. In this case we predict that fast radio bursts emit most of their luminosities in the radio band and have no strong counterpart in any other frequency bands.

  7. Calcium signaling through CaMKII regulates hepatic glucose production in fasting and obesity

    PubMed Central

    Ozcan, Lale; Wong, Catherine C.L.; Li, Gang; Xu, Tao; Pajvani, Utpal; Park, Sung Kyu Robin; Wronska, Anetta; Chen, Bi-Xing; Marks, Andrew R.; Fukamizu, Akiyoshi; Backs, Johannes; Singer, Harold A.; Yates, John R.; Accili, Domenico; Tabas, Ira

    2012-01-01

    SUMMARY Hepatic glucose production (HGP) is crucial for glucose homeostasis, but the underlying mechanisms have not been fully elucidated. Here we show that a calcium-sensing enzyme, CaMKII, is activated in a calcium- and IP3R-dependent manner by cAMP and glucagon in primary HCs and by glucagon and fasting in vivo. Genetic deficiency or inhibition of CaMKII blocks nuclear translocation of FoxO1 by affecting its phosphorylation, impairs fasting- and glucagon/cAMP-induced glycogenolysis and gluconeogenesis, and lowers blood glucose levels, while constitutively active CaMKII has the opposite effects. Importantly, the suppressive effect of CaMKII deficiency on glucose metabolism is abrogated by transduction with constitutively nuclear FoxO1, indicating that the effect of CaMKII deficiency requires nuclear exclusion of FoxO1. This same pathway is also involved in excessive HGP in the setting of obesity. These results reveal a calcium-mediated signaling pathway involved in FoxO1 nuclear localization and hepatic glucose homeostasis. PMID:22503562

  8. Real-Time Robust Tracking for Motion Blur and Fast Motion via Correlation Filters.

    PubMed

    Xu, Lingyun; Luo, Haibo; Hui, Bin; Chang, Zheng

    2016-09-07

    Visual tracking has extensive applications in intelligent monitoring and guidance systems. Among state-of-the-art tracking algorithms, Correlation Filter methods perform favorably in robustness, accuracy and speed. However, it also has shortcomings when dealing with pervasive target scale variation, motion blur and fast motion. In this paper we proposed a new real-time robust scheme based on Kernelized Correlation Filter (KCF) to significantly improve performance on motion blur and fast motion. By fusing KCF and STC trackers, our algorithm also solve the estimation of scale variation in many scenarios. We theoretically analyze the problem for CFs towards motions and utilize the point sharpness function of the target patch to evaluate the motion state of target. Then we set up an efficient scheme to handle the motion and scale variation without much time consuming. Our algorithm preserves the properties of KCF besides the ability to handle special scenarios. In the end extensive experimental results on benchmark of VOT datasets show our algorithm performs advantageously competed with the top-rank trackers.

  9. FAST CARS: Engineering a laser spectroscopic technique for rapid identification of bacterial spores

    PubMed Central

    Scully, M. O.; Kattawar, G. W.; Lucht, R. P.; Opatrný, T.; Pilloff, H.; Rebane, A.; Sokolov, A. V.; Zubairy, M. S.

    2002-01-01

    Airborne contaminants, e.g., bacterial spores, are usually analyzed by time-consuming microscopic, chemical, and biological assays. Current research into real-time laser spectroscopic detectors of such contaminants is based on e.g., resonance fluorescence. The present approach derives from recent experiments in which atoms and molecules are prepared by one (or more) coherent laser(s) and probed by another set of lasers. However, generating and using maximally coherent oscillation in macromolecules having an enormous number of degrees of freedom is challenging. In particular, the short dephasing times and rapid internal conversion rates are major obstacles. However, adiabatic fast passage techniques and the ability to generate combs of phase-coherent femtosecond pulses provide tools for the generation and utilization of maximal quantum coherence in large molecules and biopolymers. We call this technique FAST CARS (femtosecond adaptive spectroscopic techniques for coherent anti-Stokes Raman spectroscopy), and the present article proposes and analyses ways in which it could be used to rapidly identify preselected molecules in real time. PMID:12177405

  10. Fast visible imaging of turbulent plasma in TORPEX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iraji, D.; Diallo, A.; Fasoli, A.

    2008-10-15

    Fast framing cameras constitute an important recent diagnostic development aimed at monitoring light emission from magnetically confined plasmas, and are now commonly used to study turbulence in plasmas. In the TORPEX toroidal device [A. Fasoli et al., Phys. Plasmas 13, 055902 (2006)], low frequency electrostatic fluctuations associated with drift-interchange waves are routinely measured by means of extensive sets of Langmuir probes. A Photron Ultima APX-RS fast framing camera has recently been acquired to complement Langmuir probe measurements, which allows comparing statistical and spectral properties of visible light and electrostatic fluctuations. A direct imaging system has been developed, which allows viewingmore » the light, emitted from microwave-produced plasmas tangentially and perpendicularly to the toroidal direction. The comparison of the probability density function, power spectral density, and autoconditional average of the camera data to those obtained using a multiple head electrostatic probe covering the plasma cross section shows reasonable agreement in the case of perpendicular view and in the plasma region where interchange modes dominate.« less

  11. Autofocus algorithm using one-dimensional Fourier transform and Pearson correlation

    NASA Astrophysics Data System (ADS)

    Bueno Mario, A.; Alvarez-Borrego, Josue; Acho, L.

    2004-10-01

    A new autofocus algorithm based on one-dimensional Fourier transform and Pearson correlation for Z automatized microscope is proposed. Our goal is to determine in fast response time and accuracy, the best focused plane through an algorithm. We capture in bright and dark field several images set at different Z distances from biological organism sample. The algorithm uses the one-dimensional Fourier transform to obtain the image frequency content of a vectors pattern previously defined comparing the Pearson correlation of these frequency vectors versus the reference image frequency vector, the most out of focus image, we find the best focusing. Experimental results showed the algorithm has fast response time and accuracy in getting the best focus plane from captured images. In conclusions, the algorithm can be implemented in real time systems due fast response time, accuracy and robustness. The algorithm can be used to get focused images in bright and dark field and it can be extended to include fusion techniques to construct multifocus final images beyond of this paper.

  12. High Quality 3D Photonics using Nano Imprint Lithography of Fast Sol-gel Materials.

    PubMed

    Bar-On, Ofer; Brenner, Philipp; Siegle, Tobias; Gvishi, Raz; Kalt, Heinz; Lemmer, Uli; Scheuer, Jacob

    2018-05-18

    A method for the realization of low-loss integrated optical components is proposed and demonstrated. This approach is simple, fast, inexpensive, scalable for mass production, and compatible with both 2D and 3D geometries. The process is based on a novel dual-step soft nano imprint lithography process for producing devices with smooth surfaces, combined with fast sol-gel technology providing highly transparent materials. As a concrete example, this approach is demonstrated on a micro ring resonator made by direct laser writing (DLW) to achieve a quality factor improvement from one hundred thousand to more than 3 million. To the best of our knowledge this also sets a Q-factor record for UV-curable integrated micro-ring resonators. The process supports the integration of many types of materials such as light-emitting, electro-optic, piezo-electric, and can be readily applied to a wide variety of devices such as waveguides, lenses, diffractive elements and more.

  13. Flexible, fast and accurate sequence alignment profiling on GPGPU with PaSWAS.

    PubMed

    Warris, Sven; Yalcin, Feyruz; Jackson, Katherine J L; Nap, Jan Peter

    2015-01-01

    To obtain large-scale sequence alignments in a fast and flexible way is an important step in the analyses of next generation sequencing data. Applications based on the Smith-Waterman (SW) algorithm are often either not fast enough, limited to dedicated tasks or not sufficiently accurate due to statistical issues. Current SW implementations that run on graphics hardware do not report the alignment details necessary for further analysis. With the Parallel SW Alignment Software (PaSWAS) it is possible (a) to have easy access to the computational power of NVIDIA-based general purpose graphics processing units (GPGPUs) to perform high-speed sequence alignments, and (b) retrieve relevant information such as score, number of gaps and mismatches. The software reports multiple hits per alignment. The added value of the new SW implementation is demonstrated with two test cases: (1) tag recovery in next generation sequence data and (2) isotype assignment within an immunoglobulin 454 sequence data set. Both cases show the usability and versatility of the new parallel Smith-Waterman implementation.

  14. Fast imaging of live organisms with sculpted light sheets

    NASA Astrophysics Data System (ADS)

    Chmielewski, Aleksander K.; Kyrsting, Anders; Mahou, Pierre; Wayland, Matthew T.; Muresan, Leila; Evers, Jan Felix; Kaminski, Clemens F.

    2015-04-01

    Light-sheet microscopy is an increasingly popular technique in the life sciences due to its fast 3D imaging capability of fluorescent samples with low photo toxicity compared to confocal methods. In this work we present a new, fast, flexible and simple to implement method to optimize the illumination light-sheet to the requirement at hand. A telescope composed of two electrically tuneable lenses enables us to define thickness and position of the light-sheet independently but accurately within milliseconds, and therefore optimize image quality of the features of interest interactively. We demonstrated the practical benefit of this technique by 1) assembling large field of views from tiled single exposure each with individually optimized illumination settings; 2) sculpting the light-sheet to trace complex sample shapes within single exposures. This technique proved compatible with confocal line scanning detection, further improving image contrast and resolution. Finally, we determined the effect of light-sheet optimization in the context of scattering tissue, devising procedures for balancing image quality, field of view and acquisition speed.

  15. Genarris: Random generation of molecular crystal structures and fast screening with a Harris approximation

    NASA Astrophysics Data System (ADS)

    Li, Xiayue; Curtis, Farren S.; Rose, Timothy; Schober, Christoph; Vazquez-Mayagoitia, Alvaro; Reuter, Karsten; Oberhofer, Harald; Marom, Noa

    2018-06-01

    We present Genarris, a Python package that performs configuration space screening for molecular crystals of rigid molecules by random sampling with physical constraints. For fast energy evaluations, Genarris employs a Harris approximation, whereby the total density of a molecular crystal is constructed via superposition of single molecule densities. Dispersion-inclusive density functional theory is then used for the Harris density without performing a self-consistency cycle. Genarris uses machine learning for clustering, based on a relative coordinate descriptor developed specifically for molecular crystals, which is shown to be robust in identifying packing motif similarity. In addition to random structure generation, Genarris offers three workflows based on different sequences of successive clustering and selection steps: the "Rigorous" workflow is an exhaustive exploration of the potential energy landscape, the "Energy" workflow produces a set of low energy structures, and the "Diverse" workflow produces a maximally diverse set of structures. The latter is recommended for generating initial populations for genetic algorithms. Here, the implementation of Genarris is reported and its application is demonstrated for three test cases.

  16. Fast non-Abelian geometric gates via transitionless quantum driving.

    PubMed

    Zhang, J; Kyaw, Thi Ha; Tong, D M; Sjöqvist, Erik; Kwek, Leong-Chuan

    2015-12-21

    A practical quantum computer must be capable of performing high fidelity quantum gates on a set of quantum bits (qubits). In the presence of noise, the realization of such gates poses daunting challenges. Geometric phases, which possess intrinsic noise-tolerant features, hold the promise for performing robust quantum computation. In particular, quantum holonomies, i.e., non-Abelian geometric phases, naturally lead to universal quantum computation due to their non-commutativity. Although quantum gates based on adiabatic holonomies have already been proposed, the slow evolution eventually compromises qubit coherence and computational power. Here, we propose a general approach to speed up an implementation of adiabatic holonomic gates by using transitionless driving techniques and show how such a universal set of fast geometric quantum gates in a superconducting circuit architecture can be obtained in an all-geometric approach. Compared with standard non-adiabatic holonomic quantum computation, the holonomies obtained in our approach tends asymptotically to those of the adiabatic approach in the long run-time limit and thus might open up a new horizon for realizing a practical quantum computer.

  17. Fast non-Abelian geometric gates via transitionless quantum driving

    PubMed Central

    Zhang, J.; Kyaw, Thi Ha; Tong, D. M.; Sjöqvist, Erik; Kwek, Leong-Chuan

    2015-01-01

    A practical quantum computer must be capable of performing high fidelity quantum gates on a set of quantum bits (qubits). In the presence of noise, the realization of such gates poses daunting challenges. Geometric phases, which possess intrinsic noise-tolerant features, hold the promise for performing robust quantum computation. In particular, quantum holonomies, i.e., non-Abelian geometric phases, naturally lead to universal quantum computation due to their non-commutativity. Although quantum gates based on adiabatic holonomies have already been proposed, the slow evolution eventually compromises qubit coherence and computational power. Here, we propose a general approach to speed up an implementation of adiabatic holonomic gates by using transitionless driving techniques and show how such a universal set of fast geometric quantum gates in a superconducting circuit architecture can be obtained in an all-geometric approach. Compared with standard non-adiabatic holonomic quantum computation, the holonomies obtained in our approach tends asymptotically to those of the adiabatic approach in the long run-time limit and thus might open up a new horizon for realizing a practical quantum computer. PMID:26687580

  18. Discriminant analysis for fast multiclass data classification through regularized kernel function approximation.

    PubMed

    Ghorai, Santanu; Mukherjee, Anirban; Dutta, Pranab K

    2010-06-01

    In this brief we have proposed the multiclass data classification by computationally inexpensive discriminant analysis through vector-valued regularized kernel function approximation (VVRKFA). VVRKFA being an extension of fast regularized kernel function approximation (FRKFA), provides the vector-valued response at single step. The VVRKFA finds a linear operator and a bias vector by using a reduced kernel that maps a pattern from feature space into the low dimensional label space. The classification of patterns is carried out in this low dimensional label subspace. A test pattern is classified depending on its proximity to class centroids. The effectiveness of the proposed method is experimentally verified and compared with multiclass support vector machine (SVM) on several benchmark data sets as well as on gene microarray data for multi-category cancer classification. The results indicate the significant improvement in both training and testing time compared to that of multiclass SVM with comparable testing accuracy principally in large data sets. Experiments in this brief also serve as comparison of performance of VVRKFA with stratified random sampling and sub-sampling.

  19. Fast interrupt platform for extended DOS

    NASA Technical Reports Server (NTRS)

    Duryea, T. W.

    1995-01-01

    Extended DOS offers the unique combination of a simple operating system which allows direct access to the interrupt tables, 32 bit protected mode access to 4096 MByte address space, and the use of industry standard C compilers. The drawback is that fast interrupt handling requires both 32 bit and 16 bit versions of each real-time process interrupt handler to avoid mode switches on the interrupts. A set of tools has been developed which automates the process of transforming the output of a standard 32 bit C compiler to 16 bit interrupt code which directly handles the real mode interrupts. The entire process compiles one set of source code via a make file, which boosts productivity by making the management of the compile-link cycle very simple. The software components are in the form of classes written mostly in C. A foreground process written as a conventional application which can use the standard C libraries can communicate with the background real-time classes via a message passing mechanism. The platform thus enables the integration of high performance real-time processing into a conventional application framework.

  20. Electroconvulsive therapy in the intensive care unit for the treatment of catatonia: a case series and review of the literature.

    PubMed

    Dessens, Femke M; van Paassen, Judith; van Westerloo, David J; van der Wee, Nic J; van Vliet, Irene M; van Noorden, Martijn S

    2016-01-01

    Catatonia is an underdiagnosed syndrome that may occur in severely ill patients. The malignant subtype, consisting of motor symptoms, autonomic instability and fever, is associated with high mortality rates, though exact current mortality rates are unknown. This subtype requires a fast detection and treatment with high doses of a benzodiazepine or electroconvulsive therapy (ECT), preferably in an intensive care unit (ICU) setting. Case series and qualitative literature review. This paper presents four patients admitted to the ICU of an academic hospital diagnosed with malignant catatonia. All patients received ECT after an ineffective trial of high-dose intravenous benzodiazepine treatment. The duration of ECT ranged from 6 to 23 treatments after which the catatonic features partially or fully remitted. In addition, we have reviewed the diagnostic challenges, neurobiology, possible causes, differential diagnosis and treatment options of catatonia, focusing on the treatment with ECT and the importance of detection and multidisciplinary collaboration. Malignant catatonia is an underdiagnosed, potentially life-threatening syndrome that requires fast recognition and prompt treatment, preferably in an ICU setting. Copyright © 2016 Elsevier Inc. All rights reserved.

Top