Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-13
...: Fast Track Drug Development Programs: Designation, Development, and Application Review AGENCY: Food and... licenses for fast track designation as provided in the guidance for industry on fast track drug development... appropriate, and other forms of information technology. Guidance for Industry: Fast Track Drug Development...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-28
... Request; Guidance for Industry: Fast Track Drug Development Programs: Designation, Development, and... information to OMB for review and clearance. Guidance for Industry: Fast Track Drug Development Programs... to industry on fast track policies and procedures outlined in section 506 of the FD&C Act. The...
Fast Track Teaching: Beginning the Experiment in Accelerated Leadership Development
ERIC Educational Resources Information Center
Churches, Richard; Hutchinson, Geraldine; Jones, Jeff
2009-01-01
This article provides an overview of the development of the Fast Track teaching programme and personalised nature of the training and support that has been delivered. Fast Track teacher promotion rates are compared to national statistics demonstrating significant progression for certain groups, particularly women. (Contains 3 tables and 3 figures.)
"Fast Track" and "Traditional Path" Coaches: Affordances, Agency and Social Capital
ERIC Educational Resources Information Center
Rynne, Steven
2014-01-01
A recent development in large-scale coach accreditation (certification) structures has been the "fast tracking" of former elite athletes. Former elite athletes are often exempted from entry-level qualifications and are generally granted access to fast track courses that are shortened versions of the accreditation courses undertaken by…
Accelerated Leadership Development: Fast Tracking School Leaders
ERIC Educational Resources Information Center
Earley, Peter; Jones, Jeff
2010-01-01
"Accelerated Leadership Development" captures and communicates the lessons learned from successful fast-track leadership programmes in the private and public sector, and provides a model which schools can follow and customize as they plan their own leadership development strategies. As large numbers of headteachers and other senior staff…
Ender, Joerg; Borger, Michael Andrew; Scholz, Markus; Funkat, Anne-Kathrin; Anwar, Nadeem; Sommer, Marcus; Mohr, Friedrich Wilhelm; Fassl, Jens
2008-07-01
The authors compared the safety and efficacy of a newly developed fast-track concept at their center, including implementation of a direct admission postanesthetic care unit, to standard perioperative management. All fast-track patients treated within the first 6 months of implementation of our direct admission postanesthetic care unit were matched via propensity scores and compared with a historical control group of patients who underwent cardiac surgery prior to fast-track implementation. A total of 421 fast-track patients were matched successfully to 421 control patients. The two groups of patients had a similar age (64 +/- 13 vs. 64 +/- 12 yr for fast-track vs. control, P = 0.45) and European System for Cardiac Operative Risk Evaluation-predicted risk of mortality (4.8 +/- 6.1% vs. 4.6 +/- 5.1%, P = 0.97). Fast-track patients had significantly shorter times to extubation (75 min [45-110] vs. 900 min [600-1140]), as well as shorter lengths of stay in the postanesthetic or intensive care unit (4 h [3.0-5] vs. 20 h [16-25]), intermediate care unit (21 h [17-39] vs. 26 h [19-49]), and hospital (10 days [8-12] vs. 11 days [9-14]) (expressed as median and interquartile range, all P < 0.01). Fast-track patients also had a lower risk of postoperative low cardiac output syndrome (0.5% vs. 2.9%, P < 0.05) and mortality (0.5% vs. 3.3%, P < 0.01). The Leipzig fast-track protocol is a safe and effective method to manage cardiac surgery patients after a variety of operations.
[Principles of fast track surgery. Multimodal perioperative therapy programme].
Kehlet, H
2009-08-01
Recent evidence has documented that a combination of single-modality evidence-based care principles into a multimodal effort to enhance postoperative recovery (the fast track methodology) has led to enhanced recovery with reduced medical morbidity, need for hospitalisation and convalescence. Nevertheless, general implementation of fast track surgery has been relatively slow despite concomitant economic benefits. Further improvement in postoperative outcome may be obtained by developments within each care principle with a specific focus on minimally invasive surgery, effective multimodal, non-opioid analgesia and pharmacological stress reduction.
Fast Track Initiative: Building a Global Compact for Education. Education Notes
ERIC Educational Resources Information Center
Human Development Network Education, 2005
2005-01-01
This note series is intended to summarize lessons learned and key policy findings on the World Bank's work in education. "Fast Track Initiative" ("FTI") was launched in 2002 as a partnership between donor and developing countries to accelerate progress towards the Millennium Development Goal (MDG) of universal primary education. "FTI" is built on…
Fast Track Option: An Accelerated Associate's Degree Program.
ERIC Educational Resources Information Center
Price, J. Randall
1998-01-01
Alternative instructional delivery options such as self-paced and flexible enrollment courses are designed to increase enrollment, promote retention, and encourage student success without lowering academic standards. The Fast Track Associate's Degree Program, developed by a team of faculty, staff, and administrators at Richland Community College,…
Effect of an emergency department fast track on Press-Ganey patient satisfaction scores.
Hwang, Calvin E; Lipman, Grant S; Kane, Marlena
2015-01-01
Mandated patient surveys have become an integral part of Medicare remuneration, putting hundreds of millions of dollars in funding at risk. The Centers for Medicare & Medicaid Services (CMS) recently announced a patient experience survey for the emergency department (ED). Development of an ED Fast Track, where lower acuity patients are rapidly seen, has been shown to improve many of the metrics that CMS examines. This is the first study examining if ED Fast Track implementation affects Press-Ganey scores of patient satisfaction. We analyzed returned Press-Ganey questionnaires from all ESI 4 and 5 patients seen 11AM - 1PM, August-December 2011 (pre-fast track), and during the identical hours of fast track, August-December 2012. Raw ordinal scores were converted to continuous scores for paired student t-test analysis. We calculated an odds ratio with 100% satisfaction considered a positive response. An academic ED with 52,000 annual visits had 140 pre-fast track and 85 fast track respondents. Implementation of a fast track significantly increased patient satisfaction with the following: wait times (68% satisfaction to 88%, OR 4.13, 95% CI [2.32-7.33]), doctor courtesy (90% to 95%, OR 1.97, 95% CI [1.04-3.73]), nurse courtesy (87% to 95%, OR 2.75, 95% CI [1.46-5.15]), pain control (79% to 87%, OR 2.13, 95% CI [1.16-3.92]), likelihood to recommend (81% to 90%, OR 2.62, 95% CI [1.42-4.83]), staff caring (82% to 91%, OR 2.82, 95% CI [1.54-5.19]), and staying informed about delays (66% to 83%, OR 3.00, 95% CI [1.65-5.44]). Implementation of an ED Fast Track more than doubled the odds of significant improvements in Press-Ganey patient satisfaction metrics and may play an important role in improving ED performance on CMS benchmarks.
Fast emulation of track reconstruction in the CMS simulation
NASA Astrophysics Data System (ADS)
Komm, Matthias; CMS Collaboration
2017-10-01
Simulated samples of various physics processes are a key ingredient within analyses to unlock the physics behind LHC collision data. Samples with more and more statistics are required to keep up with the increasing amounts of recorded data. During sample generation, significant computing time is spent on the reconstruction of charged particle tracks from energy deposits which additionally scales with the pileup conditions. In CMS, the FastSimulation package is developed for providing a fast alternative to the standard simulation and reconstruction workflow. It employs various techniques to emulate track reconstruction effects in particle collision events. Several analysis groups in CMS are utilizing the package, in particular those requiring many samples to scan the parameter space of physics models (e.g. SUSY) or for the purpose of estimating systematic uncertainties. The strategies for and recent developments in this emulation are presented, including a novel, flexible implementation of tracking emulation while retaining a sufficient, tuneable accuracy.
Preventing Serious Conduct Problems in School-Age Youth: The Fast Track Program
ERIC Educational Resources Information Center
Slough, Nancy M.; McMahon, Robert J.; Bierman, Karen L.; Coie, John D.; Dodge, Kenneth A.; Foster, E. Michael; Greenberg, Mark T.; Lochman, John E.; McMahon, Robert J.; Pinderhughes, Ellen E.
2008-01-01
Children with early-starting conduct problems have a very poor prognosis and exact a high cost to society. The Fast Track project is a multisite, collaborative research project investigating the efficacy of a comprehensive, long-term, multicomponent intervention designed to "prevent" the development of serious conduct problems in high-risk…
Pasalich, Dave S.; Witkiewitz, Katie; McMahon, Robert J.; Pinderhughes, Ellen E.
2016-01-01
Little is known about intervening processes that explain how prevention programs improve particular youth antisocial outcomes. We examined whether parental harsh discipline and warmth in childhood differentially account for Fast Track intervention effects on conduct disorder (CD) symptoms and callous-unemotional (CU) traits in early adolescence. Participants included 891 high-risk kindergarteners (69% male; 51% African American) from urban and rural United States communities who were randomized into either the Fast Track intervention (n = 445) or non-intervention control (n = 446) groups. The 10-year intervention included parent management training and other services (e.g., social skills training, universal classroom curriculum) targeting various risk factors for the development of conduct problems. Harsh discipline (Grades 1 through 3) and warmth (Grades 1 and 2) were measured using parent responses to vignettes and direct observations of parent-child interaction, respectively. Parents reported on children’s CD symptoms in Grade 6 and CU traits in Grade 7. Results demonstrated indirect effects of the Fast Track intervention on reducing risk for youth antisocial outcomes. That is, Fast Track was associated with lower scores on harsh discipline, which in turn predicted decreased levels of CD symptoms. In addition, Fast Track was associated with higher scores on warmth, which in turn predicted reduced levels of CU traits. Our findings inform developmental and intervention models of youth antisocial behavior by providing evidence for the differential role of harsh discipline and warmth in accounting for indirect effects of Fast Track on CD symptoms versus CU traits, respectively. PMID:26242993
Pasalich, Dave S; Witkiewitz, Katie; McMahon, Robert J; Pinderhughes, Ellen E
2016-04-01
Little is known about intervening processes that explain how prevention programs improve particular youth antisocial outcomes. We examined whether parental harsh discipline and warmth in childhood differentially account for Fast Track intervention effects on conduct disorder (CD) symptoms and callous-unemotional (CU) traits in early adolescence. Participants included 891 high-risk kindergarteners (69% male; 51% African American) from urban and rural United States communities who were randomized into either the Fast Track intervention (n = 445) or non-intervention control (n = 446) groups. The 10-year intervention included parent management training and other services (e.g., social skills training, universal classroom curriculum) targeting various risk factors for the development of conduct problems. Harsh discipline (Grades 1 to 3) and warmth (Grades 1 and 2) were measured using parent responses to vignettes and direct observations of parent-child interaction, respectively. Parents reported on children's CD symptoms in Grade 6 and CU traits in Grade 7. Results demonstrated indirect effects of the Fast Track intervention on reducing risk for youth antisocial outcomes. That is, Fast Track was associated with lower scores on harsh discipline, which in turn predicted decreased levels of CD symptoms. In addition, Fast Track was associated with higher scores on warmth, which in turn predicted reduced levels of CU traits. Our findings inform developmental and intervention models of youth antisocial behavior by providing evidence for the differential role of harsh discipline and warmth in accounting for indirect effects of Fast Track on CD symptoms versus CU traits, respectively.
NASA Astrophysics Data System (ADS)
Webster, Jordan
2017-01-01
Dense track environments in pp collisions at the Large Hadron Collider (LHC) motivate the use of triggers with dedicated hardware for fast track reconstruction. The ATLAS Collaboration is in the process of implementing a Fast Tracker (FTK) trigger upgrade, in which Content Addressable Memories (CAMs) will be used to rapidly match hit patterns with large banks of simulated tracks. The FTK CAMs are produced primarily at the University of Pisa. However, commercial CAM technology is rapidly developing due to applications in computer networking devices. This poster presents new studies comparing FTK CAMs to cutting-edge ternary CAMs developed by Cavium. The comparison is intended to guide the design of future track-based trigger systems for the next Phase at the LHC.
Philp, Shannon; Carter, J; Barnett, C; DʼAbrew, N; Pather, S; White, K
2015-01-01
This study examines the role of the fast-track nurse in gynecology from a patient perspective. The fast-track nurse is a specialist nursing role, which coordinates patient care, in addition to providing specialized clinical care. Semistructured interviews were conducted with women who had fast-track surgery for gynecological cancer.
Implementation and audit of 'Fast-Track Surgery' in gynaecological oncology surgery.
Sidhu, Verinder S; Lancaster, Letitia; Elliott, David; Brand, Alison H
2012-08-01
Fast-track surgery is a multidisciplinary approach to surgery that results in faster recovery from surgery and decreased length of stay (LOS). The aims of this study were as follows: (i) to report on the processes required for the introduction of fast-track surgery to a gynaecological oncology unit and (ii) to report the results of a clinical audit conducted after the protocol's implementation. A fast-track protocol, specific to our unit, was developed after a series of multidisciplinary meetings. The protocol, agreed upon by those involved in the care of women in our unit, was then introduced into clinical practice. An audit was conducted of all women undergoing laparotomy, with known or suspected malignancy. Information on LOS, complication and readmission rates was collected. Descriptive statistics and Poisson regression were used for statistical analysis. The developed protocol involved a multidisciplinary approach to pre-, intra- and postoperative care. The audit included 104 consecutive women over a 6-month period, who were followed for 6 weeks postoperatively. The median LOS was 4 days. The readmission rate was 7% and the complication rate was 19% (1% intraoperative, 4% major and 14% minor). Multivariate analysis revealed that increased duration of surgery and increasing age were predictors of longer LOS. The development of a fast-track protocol is achievable in a gynaecological oncology unit, with input from a multidisciplinary team. Effective implementation of the protocol can result in a short LOS, with acceptable complication and readmission rates when applied non-selectively to gynaecological oncology patients. © 2012 The Authors ANZJOG © 2012 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.
Wind, Jan; Hofland, Jan; Preckel, Benedikt; Hollmann, Markus W; Bossuyt, Patrick MM; Gouma, Dirk J; van Berge Henegouwen, Mark I; Fuhring, Jan Willem; Dejong, Cornelis HC; van Dam, Ronald M; Cuesta, Miguel A; Noordhuis, Astrid; de Jong, Dick; van Zalingen, Edith; Engel, Alexander F; Goei, T Hauwy; de Stoppelaar, I Erica; van Tets, Willem F; van Wagensveld, Bart A; Swart, Annemiek; van den Elsen, Maarten JLJ; Gerhards, Michael F; de Wit, Laurens Th; Siepel, Muriel AM; van Geloven, Anna AW; Juttmann, Jan-Willem; Clevers, Wilfred; Bemelman, Willem A
2006-01-01
Background Recent developments in large bowel surgery are the introduction of laparoscopic surgery and the implementation of multimodal fast track recovery programs. Both focus on a faster recovery and shorter hospital stay. The randomized controlled multicenter LAFA-trial (LAparoscopy and/or FAst track multimodal management versus standard care) was conceived to determine whether laparoscopic surgery, fast track perioperative care or a combination of both is to be preferred over open surgery with standard care in patients having segmental colectomy for malignant disease. Methods/design The LAFA-trial is a double blinded, multicenter trial with a 2 × 2 balanced factorial design. Patients eligible for segmental colectomy for malignant colorectal disease i.e. right and left colectomy and anterior resection will be randomized to either open or laparoscopic colectomy, and to either standard care or the fast track program. This factorial design produces four treatment groups; open colectomy with standard care (a), open colectomy with fast track program (b), laparoscopic colectomy with standard care (c), and laparoscopic surgery with fast track program (d). Primary outcome parameter is postoperative hospital length of stay including readmission within 30 days. Secondary outcome parameters are quality of life two and four weeks after surgery, overall hospital costs, morbidity, patient satisfaction and readmission rate. Based on a mean postoperative hospital stay of 9 +/- 2.5 days a group size of 400 patients (100 each arm) can reliably detect a minimum difference of 1 day between the four arms (alfa = 0.95, beta = 0.8). With 100 patients in each arm a difference of 10% in subscales of the Short Form 36 (SF-36) questionnaire and social functioning can be detected. Discussion The LAFA-trial is a randomized controlled multicenter trial that will provide evidence on the merits of fast track perioperative care and laparoscopic colorectal surgery in patients having segmental colectomy for malignant disease. PMID:17134506
Preventing Serious Conduct Problems in School-Age Youths: The Fast Track Program
Slough, Nancy M.; McMahon, Robert J.; Bierman, Karen L.; Coie, John D.; Dodge, Kenneth A.; Foster, E. Michael; Greenberg, Mark T.; Lochman, John E.; McMahon, Robert J.; Pinderhughes, Ellen E.
2009-01-01
Children with early-starting conduct Problems have a very poor prognosis and exact a high cost to society. The Fast Track project is a multisite, collaborative research project investigating the efficacy of a comprehensive, long-term, multicomponent intervention designed to prevent the development of serious conduct problems in high-risk children. In this article, we (a) provide an overview of the development model that serves as the conceptual foundation for the Fast Track intervention and describe its integration into the intervention model; (b) outline the research design and intervention model, with an emphasis on the elementary school phase of the intervention; and (c) summarize findings to dale concerning intervention outcomes. We then provide a case illustration, and conclude with a discussion of guidelines for practitioners who work with children with conduct problems. PMID:19890487
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2012 CFR
2012-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires expeditious resolution. Fast Track procedures may include expedited...
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2011 CFR
2011-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires expeditious resolution. Fast Track procedures may include expedited...
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2010 CFR
2010-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires expeditious resolution. Fast Track procedures may include expedited...
NASA Technical Reports Server (NTRS)
1996-01-01
The NASA Fast Track Study supports the efforts of a Special Study Group (SSG) made up of members of the Advanced Project Management Class number 23 (APM-23) that met at the Wallops Island Management Education Center from April 28 - May 8, 1996. Members of the Class expressed interest to Mr. Vem Weyers in having an input to the NASA Policy Document (NPD) 7120.4, that will replace NASA Management Institute (NMI) 7120.4, and the NASA Program/Project Management Guide. The APM-23 SSG was tasked with assisting in development of NASA policy on managing Fast Track Projects, defined as small projects under $150 million and completed within three years. 'Me approach of the APM-23 SSG was to gather data on successful projects working in a 'Better, Faster, Cheaper' environment, within and outside of NASA and develop the Fast Track Project section of the NASA Program/Project Management Guide. Fourteen interviews and four other data gathering efforts were conducted by the SSG, and 16 were conducted by Strategic Resources, Inc. (SRI), including five interviews at the Jet Propulsion Laboratory (JPL) and one at the Applied Physics Laboratory (APL). The interviews were compiled and analyzed for techniques and approaches commonly used to meet severe cost and schedule constraints.
40 CFR 72.82 - Fast-track modifications.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Fast-track modifications. 72.82... (CONTINUED) PERMITS REGULATION Permit Revisions § 72.82 Fast-track modifications. The following procedures shall apply to all fast-track modifications. (a) If the Administrator is the permitting authority, the...
40 CFR 72.82 - Fast-track modifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Fast-track modifications. 72.82... (CONTINUED) PERMITS REGULATION Permit Revisions § 72.82 Fast-track modifications. The following procedures shall apply to all fast-track modifications. (a) If the Administrator is the permitting authority, the...
40 CFR 72.82 - Fast-track modifications.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Fast-track modifications. 72.82... (CONTINUED) PERMITS REGULATION Permit Revisions § 72.82 Fast-track modifications. The following procedures shall apply to all fast-track modifications. (a) If the Administrator is the permitting authority, the...
40 CFR 72.82 - Fast-track modifications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Fast-track modifications. 72.82... (CONTINUED) PERMITS REGULATION Permit Revisions § 72.82 Fast-track modifications. The following procedures shall apply to all fast-track modifications. (a) If the Administrator is the permitting authority, the...
40 CFR 72.82 - Fast-track modifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Fast-track modifications. 72.82... (CONTINUED) PERMITS REGULATION Permit Revisions § 72.82 Fast-track modifications. The following procedures shall apply to all fast-track modifications. (a) If the Administrator is the permitting authority, the...
Beogo, Idrissa; Liu, Chieh-Yu; Dlamini, Colile P; Gagnon, Marie-Pierre
2015-01-01
Nursing education has evolved over time to fit societies' increasing care needs. Innovations in nursing education draw thorny debates on potential jeopardy in the quality, safety, and efficacy of nurse graduates. Accelerated nursing education programs have been among landmark strategic changes to address the persistent bedside nurse shortage. Despite the dearth of empirical studies in sub-Saharan Africa (SSA), the National School of Public Health of Burkina Faso has developed a State Diploma Nursing (SDN) fast-track program. With innovative features, the program is nested into the traditional SDN program. This study investigates preliminary outcomes of the implemented policy using the initial cohort that went through the program. Comparison of the traditional generic program and the fast-track one is drawn to inform nursing education policy. The study was conducted in the three campuses delivering the SDN program. Data collected from a representative sample included 255 students from the 2006-2009 cohort, after concluding the program. Surveyed students were assessed according to the program entry status. Outcomes were measured using students' academic performance. Besides descriptive analysis, bivariate t-test, F-test, and multivariate ordinary least square regression (OLSR) were employed to determine the comparative pattern between the traditional generic and the newly nested fast-track program. Students' varied statuses (private pre-registration, state pre-registration, private post-registration, and state post-registration) were kept to better outline the findings trend. A fifth (19.6 %) of surveyed students were enrolled in the fast-track stream from which, one third (33.7 %) consisted of post-registered students. Fast-track students comparatively achieved the best academic performance (mean: 73.68/100, SD: 5.52). Multivariate OLSR confirmed that fast-track students performed better (β: 5.559, p < 0.001), and further informed differences between campuses. Students entry status also displayed significant differences, yet the academic performance of post-registered students from traditional generic versus fast-track was similar (p = 0.409). Findings suggest that fast-track program students performed better than the ones from the traditional generic program. The uniqueness and success of this mixed nursing program experience sheds light for nursing educators engaged in policy making. The study results can serve as a crucial foundation for policymakers to alleviate the nurse shortage in SSA.
NASA Technical Reports Server (NTRS)
Hoffman, Edward J. (Editor); Lawbaugh, William M. (Editor)
1997-01-01
Topics Considered Include: NASA's Shared Experiences Program; Core Issues for the Future of the Agency; National Space Policy Strategic Management; ISO 9000 and NASA; New Acquisition Initiatives; Full Cost Initiative; PM Career Development; PM Project Database; NASA Fast Track Studies; Fast Track Projects; Earned Value Concept; Value-Added Metrics; Saturn Corporation Lessons Learned; Project Manager Credibility.
42 CFR 422.626 - Fast-track appeals of service terminations to independent review entities (IREs).
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 3 2013-10-01 2013-10-01 false Fast-track appeals of service terminations to... ADVANTAGE PROGRAM Grievances, Organization Determinations and Appeals § 422.626 Fast-track appeals of service terminations to independent review entities (IREs). (a) Enrollee's right to a fast-track appeal of...
42 CFR 422.626 - Fast-track appeals of service terminations to independent review entities (IREs).
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 3 2012-10-01 2012-10-01 false Fast-track appeals of service terminations to... ADVANTAGE PROGRAM Grievances, Organization Determinations and Appeals § 422.626 Fast-track appeals of service terminations to independent review entities (IREs). (a) Enrollee's right to a fast-track appeal of...
42 CFR 422.626 - Fast-track appeals of service terminations to independent review entities (IREs).
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 3 2014-10-01 2014-10-01 false Fast-track appeals of service terminations to... ADVANTAGE PROGRAM Grievances, Organization Determinations and Appeals § 422.626 Fast-track appeals of service terminations to independent review entities (IREs). (a) Enrollee's right to a fast-track appeal of...
How Does the Fast Track Intervention Prevent Adverse Outcomes in Young Adulthood?
Sorensen, Lucy C; Dodge, Kenneth A
2016-01-01
Numerous studies have shown that childhood interventions can foster improved outcomes in adulthood. Less well understood is precisely how-that is, through which developmental pathways-these interventions work. This study assesses mechanisms by which the Fast Track project (n = 891), a randomized intervention in the early 1990s for high-risk children in four communities (Durham, NC; Nashville, TN; rural PA; and Seattle, WA), reduced delinquency, arrests, and general and mental health service utilization in adolescence through young adulthood (ages 12-20). A decomposition of treatment effects indicates that about a third of Fast Track's impact on later crime outcomes can be accounted for by improvements in social and self-regulation skills during childhood (ages 6-11), such as prosocial behavior, emotion regulation, and problem solving. These skills proved less valuable for the prevention of general and mental health problems. © 2015 The Authors. Child Development © 2015 Society for Research in Child Development, Inc.
The new millennium program: Fast-track procurements
NASA Astrophysics Data System (ADS)
Metzger, Robert M.
1996-11-01
The National Aeronautics and Space Administration's (NASA's) New Millennium Program (NMP) has embarked on a technology flight-validation demonstration program to enable the kinds of missions that NASA envisions for the 21st century. Embedded in this program is the concept of rapid mission development supported by a fast-track procurement process. This process begins with the decision to initiate a procurement very early in the program along with the formation of a technical acquisition team. A close working relationship among the team members is essential to avoiding delays and developing a clear acquisition plan. The request for proposal (RFP) that is subsequently issued seeks a company with proven capabilities, so that the time allotted for responses from proposers and the length of proposals they submit can be shortened. The fast-track procurement process has been demonstrated during selection of NMP's industrial partners and has been proven to work.
Fast-track surgery: Toward comprehensive peri-operative care
Nanavati, Aditya J.; Prabhakar, S.
2014-01-01
Fast-track surgery is a multimodal approach to patient care using a combination of several evidence-based peri-operative interventions to expedite recovery after surgery. It is an extension of the critical pathway that integrates modalities in surgery, anesthesia, and nutrition, enforces early mobilization and feeding, and emphasizes reduction of the surgical stress response. It entails a great partnership between a surgeon and an anesthesiologist with several other specialists to form a multi-disciplinary team, which may then engage in patient care. The practice of fast-track surgery has yielded excellent results and there has been a significant reduction in hospital stay without a rise in complications or re-admissions. The effective implementation begins with the formulation of a protocol, carrying out each intervention and gathering outcome data. The care of a patient is divided into three phases: Before, during, and after surgery. Each stage needs active participation of few or all the members of the multi-disciplinary team. Other than surgical technique, anesthetic drugs, and techniques form the cornerstone in the ability of the surgeon to carry out a fast-track surgery safely. It is also the role of this team to keep abreast with the latest development in fast-track methodology and make appropriate changes to policy. In the Indian healthcare system, there is a huge benefit that may be achieved by the successful implementation of a fast-track surgery program at an institutional level. The lack of awareness regarding this concept, fear and apprehension regarding its implementation are the main barriers that need to be overcome. PMID:25886214
Fast-track surgery: Toward comprehensive peri-operative care.
Nanavati, Aditya J; Prabhakar, S
2014-01-01
Fast-track surgery is a multimodal approach to patient care using a combination of several evidence-based peri-operative interventions to expedite recovery after surgery. It is an extension of the critical pathway that integrates modalities in surgery, anesthesia, and nutrition, enforces early mobilization and feeding, and emphasizes reduction of the surgical stress response. It entails a great partnership between a surgeon and an anesthesiologist with several other specialists to form a multi-disciplinary team, which may then engage in patient care. The practice of fast-track surgery has yielded excellent results and there has been a significant reduction in hospital stay without a rise in complications or re-admissions. The effective implementation begins with the formulation of a protocol, carrying out each intervention and gathering outcome data. The care of a patient is divided into three phases: Before, during, and after surgery. Each stage needs active participation of few or all the members of the multi-disciplinary team. Other than surgical technique, anesthetic drugs, and techniques form the cornerstone in the ability of the surgeon to carry out a fast-track surgery safely. It is also the role of this team to keep abreast with the latest development in fast-track methodology and make appropriate changes to policy. In the Indian healthcare system, there is a huge benefit that may be achieved by the successful implementation of a fast-track surgery program at an institutional level. The lack of awareness regarding this concept, fear and apprehension regarding its implementation are the main barriers that need to be overcome.
42 CFR 422.626 - Fast-track appeals of service terminations to independent review entities (IREs).
Code of Federal Regulations, 2010 CFR
2010-10-01
... Grievances, Organization Determinations and Appeals § 422.626 Fast-track appeals of service terminations to independent review entities (IREs). (a) Enrollee's right to a fast-track appeal of an MA organization's termination decision. An enrollee of an MA organization has a right to a fast-track appeal of an MA...
42 CFR 422.626 - Fast-track appeals of service terminations to independent review entities (IREs).
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 3 2011-10-01 2011-10-01 false Fast-track appeals of service terminations to... Grievances, Organization Determinations and Appeals § 422.626 Fast-track appeals of service terminations to independent review entities (IREs). (a) Enrollee's right to a fast-track appeal of an MA organization's...
Developmental Mediation of Genetic Variation in Response to the Fast Track Prevention Program
Albert, Dustin; Belsky, Daniel W.; Crowley, D. Max; Bates, John E.; Pettit, Gregory S.; Lansford, Jennifer E.; Dick, Danielle; Dodge, Kenneth A.
2015-01-01
We conducted a developmental analysis of genetic moderation of the effect of the Fast Track intervention on adult externalizing psychopathology. The Fast Track intervention enrolled 891 children at high risk to develop externalizing behavior problems when they were in kindergarten. Half of the enrolled children were randomly assigned to receive 10 years of treatment with a range of services and resources provided to the children and their families and the other half to usual care (controls). We previously showed that the effect of the Fast Track intervention on participants’ risk of externalizing psychopathology at age 25 years was moderated by a variant in the Glucocorticoid Receptor Gene (NR3C1). Children who carried copies of the A-allele of the single-nucleotide polymorphism rs10482672 had the highest risk of externalizing psychopathology if they were in the control arm of the trial and the lowest risk of externalizing psychopathology if they were in the treatment arm. In this study, we test a developmental hypothesis about the origins of this for-better-and-for-worse gene-by-intervention interaction (GxI): That the observed GxI effect on adult psychopathology is mediated by the proximal impact of intervention on childhood externalizing problems and adolescent substance use and delinquency. We analyzed longitudinal data tracking the 270 European-American children in the Fast Track RCT with available genetic information (129 intervention children and 141 control-group peers, 69% male) from kindergarten through age 25 years. Results show that the same pattern of “for-better-and-for-worse” susceptibility to intervention observed at the age-25 follow-up was evident already during childhood. At the elementary school follow-ups and at the middle/high-school follow-ups, rs10482672 predicted better adjustment among children receiving the Fast Track intervention, and worse adjustment among children in the control condition. In turn, these proximal GxI effects early in development mediated the ultimate GxI effect on externalizing psychopathology at age 25 years. We discuss the contribution of these findings to the growing literature on genetic susceptibility to environmental intervention. PMID:25640832
Castorina, Sergio; Guglielmino, Claudia; Castrogiovanni, Paola; Szychlinska, Marta Anna; Ioppolo, Francesco; Massimino, Paolo; Leonardi, Pietro; Maci, Christian; Iannuzzi, Maurizio; Di Giunta, Angelo; Musumeci, Giuseppe
2017-01-01
Summary Background During the last years, programs to enhance postoperative recovery and decrease morbidity after total knee arthroplasty, have been developed across a variety of surgical procedures and referred to as “Fast-Track Surgery”. In this study we aimed to find some answers in the management of osteoarthritic patients subjected to total knee arthroplasty, by using the Fast-Track methodology. To this purpose we evaluated parameters such as early mobilization of patients, better pain management, bleeding, possible complications, reduced hospitalization time, an overall improved recovery and patient satisfaction. Methods 132 patients were selected, of which, 95 treated with “Fast Track” method and 37 treated with traditional method (control group). All the patients were hospitalized and underwent the same rehabilitation program for the first three days after surgery. Results In both groups, the parameters of pain and deformity demonstrated the most rapid improvement, while those of function and movement were normalized as gradual and progressive improvement over the next 2 months. The different functional test used (Barthel, MRC, VAS) showed that the mean values were significantly greater in Fast Track group when compared to the control. Conclusion The results of the study confirm that the application of the Fast Track protocol in orthopaedics after total knee replacement results in rapid post-surgery recovery. Level of evidence IV. Case series, low-quality cohort or case-control studies. PMID:29387645
Fast track in hip arthroplasty
Hansen, Torben Bæk
2017-01-01
‘Fast-track’ surgery was introduced more than 20 years ago and may be defined as a co-ordinated peri-operative approach aimed at reducing surgical stress and facilitating post-operative recovery.The fast-track programmes have now been introduced into total hip arthroplasty (THA) surgery with reduction in post-operative length of stay, shorter convalescence and rapid functional recovery without increased morbidity and mortality. This has been achieved by focusing on a multidisciplinary collaboration and establishing ‘fast-track’ units, with a well-defined organisational set-up tailored to deliver an accelerated peri-operative course of fast-track surgical THA procedures.Fast-track THA surgery now works extremely well in the standard THA patient. However, all patients are different and fine-tuning of the multiple areas in fast-track pathways to get patients with special needs or high co-morbidity burden through a safe and effective fast-track THA pathway is important.In this narrative review, the principles of fast-track THA surgery are presented together with the present status of implementation and perspectives for further improvements. Cite this article: EFORT Open Rev 2017;2. DOI: 10.1302/2058-5241.2.160060. Originally published online at www.efortopenreviews.org PMID:28630756
Zhou, Y; Mendonca, S C; Abel, G A; Hamilton, W; Walter, F M; Johnson, S; Shelton, J; Elliss-Brookes, L; McPhail, S; Lyratzopoulos, G
2018-01-01
In England, 'fast-track' (also known as 'two-week wait') general practitioner referrals for suspected cancer in symptomatic patients are used to shorten diagnostic intervals and are supported by clinical guidelines. However, the use of the fast-track pathway may vary for different patient groups. We examined data from 669 220 patients with 35 cancers diagnosed in 2006-2010 following either fast-track or 'routine' primary-to-secondary care referrals using 'Routes to Diagnosis' data. We estimated the proportion of fast-track referrals by sociodemographic characteristic and cancer site and used logistic regression to estimate respective crude and adjusted odds ratios. We additionally explored whether sociodemographic associations varied by cancer. There were large variations in the odds of fast-track referral by cancer (P<0.001). Patients with testicular and breast cancer were most likely to have been diagnosed after a fast-track referral (adjusted odds ratios 2.73 and 2.35, respectively, using rectal cancer as reference); whereas patients with brain cancer and leukaemias least likely (adjusted odds ratios 0.05 and 0.09, respectively, for brain cancer and acute myeloid leukaemia). There were sex, age and deprivation differences in the odds of fast-track referral (P<0.013) that varied in their size and direction for patients with different cancers (P<0.001). For example, fast-track referrals were least likely in younger women with endometrial cancer and in older men with testicular cancer. Fast-track referrals are less likely for cancers characterised by nonspecific presenting symptoms and patients belonging to low cancer incidence demographic groups. Interventions beyond clinical guidelines for 'alarm' symptoms are needed to improve diagnostic timeliness.
Navigator GPS Receiver for Fast Acquisition and Weak Signal Space Applications
NASA Technical Reports Server (NTRS)
Winternitz, Luke; Moreau, Michael; Boegner, Gregory J.; Sirotzky, Steve
2004-01-01
NASA Goddard Space Flight Center (GSFC) is developing a new space-borne GPS receiver that can operate effectively in the full range of Earth orbiting missions from Low Earth Orbit (LEO) to geostationary and beyond. Navigator is designed to be a fully space flight qualified GPS receiver optimized for fast signal acquisition and weak signal tracking. The fast acquisition capabilities provide exceptional time to first fix performance (TIFF) with no a priori receiver state or GPS almanac information, even in the presence of high Doppler shifts present in LEO (or near perigee in highly eccentric orbits). The fast acquisition capability also makes it feasible to implement extended correlation intervals and therefore significantly reduce Navigator s acquisition threshold. This greatly improves GPS observability when the receiver is above the GPS constellation (and satellites must be tracked from the opposite side of the Earth) by providing at least 10 dB of increased acquisition sensitivity. Fast acquisition and weak signal tracking algorithms have been implemented and validated on a hardware development board. A fully functional version of the receiver, employing most of the flight parts, with integrated navigation software is expected by mid 2005. An ultimate goal of this project is to license the Navigator design to an industry partner who will then market the receiver as a commercial product.
Returning nurses to the workforce: developing a fast track back program.
Burns, Helen K; Sakraida, Teresa J; Englert, Nadine C; Hoffmann, Rosemary L; Tuite, Patricia; Foley, Susan M
2006-01-01
Fast Track Back: Re-entry into Nursing Practice program. Describes the development, implementation, and evaluation of a state-of-the-art re-entry program facilitating the return of licensed nonpracticing RNs to the workforce through a quality education program that retools them for the workforce in the areas of pharmacology, skill development using the latest technology, practice standards, and nursing issues. The program consists of didactic content taught via classroom, Internet, skills laboratory, and high fidelity human simulated technology and a clinical component. The program is a mechanism that enables re-entry nurses to improve skills and competencies necessary to practice in today's healthcare environment.
Multiple feature fusion via covariance matrix for visual tracking
NASA Astrophysics Data System (ADS)
Jin, Zefenfen; Hou, Zhiqiang; Yu, Wangsheng; Wang, Xin; Sun, Hui
2018-04-01
Aiming at the problem of complicated dynamic scenes in visual target tracking, a multi-feature fusion tracking algorithm based on covariance matrix is proposed to improve the robustness of the tracking algorithm. In the frame-work of quantum genetic algorithm, this paper uses the region covariance descriptor to fuse the color, edge and texture features. It also uses a fast covariance intersection algorithm to update the model. The low dimension of region covariance descriptor, the fast convergence speed and strong global optimization ability of quantum genetic algorithm, and the fast computation of fast covariance intersection algorithm are used to improve the computational efficiency of fusion, matching, and updating process, so that the algorithm achieves a fast and effective multi-feature fusion tracking. The experiments prove that the proposed algorithm can not only achieve fast and robust tracking but also effectively handle interference of occlusion, rotation, deformation, motion blur and so on.
Guldbrandt, Louise Mahncke; Fenger-Grøn, Morten; Rasmussen, Torben Riis; Jensen, Henry; Vedsted, Peter
2015-01-22
Lung cancer stage at diagnosis predicts possible curative treatment. In Denmark and the UK, lung cancer patients have lower survival rates than citizens in most other European countries, which may partly be explained by a comparatively longer diagnostic interval in these two countries. In Denmark, a pathway was introduced in 2008 allowing general practitioners (GPs) to refer patients suspected of having lung cancer directly to fast-track diagnostics. However, symptom presentation of lung cancer in general practice is known to be diverse and complex, and systematic knowledge of the routes to diagnosis is needed to enable earlier lung cancer diagnosis in Denmark. This study aims to describe the routes to diagnosis, the diagnostic activity preceding diagnosis and the diagnostic intervals for lung cancer in the Danish setting. We conducted a national registry-based cohort study on 971 consecutive incident lung cancer patients in 2010 using data from national registries and GP questionnaires. GPs were involved in 68.3% of cancer patients' diagnostic pathways, and 27.4% of lung cancer patients were referred from the GP to fast-track diagnostic work-up. A minimum of one X-ray was performed in 85.6% of all cases before diagnosis. Patients referred through a fast-track route more often had diagnostic X-rays (66.0%) than patients who did not go through fast-track (49.4%). Overall, 33.6% of all patients had two or more X-rays performed during the 90 days before diagnosis. Patients whose symptoms were interpreted as non-alarm symptoms or who were not referred to fast-track were more likely to experience a long diagnostic interval than patients whose symptoms were interpreted as alarm symptoms or who were referred to fast-track. Lung cancer patients followed several diagnostic pathways. The existing fast-track pathway must be supplemented to ensure earlier detection of lung cancer. The high incidence of multiple X-rays warrants a continued effort to develop more accurate lung cancer tests for use in primary care.
NASA Technical Reports Server (NTRS)
Cheng, W.; Wen, J. T.
1992-01-01
A novel fast learning rule with fast weight identification is proposed for the two-time-scale neural controller, and a two-stage learning strategy is developed for the proposed neural controller. The results of the stability analysis show that both the tracking error and the fast weight error will be uniformly bounded and converge to a bounded region which depends only on the accuracy of the slow learning if the system is sufficiently excited. The efficiency of the two-stage learning is also demonstrated by a simulation of a two-link arm.
2011-01-01
Background Laparoscopy-assisted surgery, fast-track perioperative treatment are both increasingly used in colorectal cancer treatment, for their short-time benefits of enhanced recovery and short hospital stays. However, the benefits of the integration of the Laparoscopy-assisted surgery, fast-track perioperative treatment, and even with the Xelox chemotherapy, are still unknown. In this study, the three treatments integration is defined as "Fast Track Multi-Discipline Treatment Model" for colorectal cancer and this model extends the benefits to the whole treatment process of colorectal cancer. The main purpose of the study is to explore the feasibility of "Fast Track Multi-Discipline Treatment" model in treatment of colorectal cancer. Methods The trial is a prospective randomized controlled study with 2 × 2 balanced factorial design. Patients eligible for the study will be randomized to 4 groups: (I) Laparoscopic surgery with fast track perioperative treatment and Xelox chemotherapy; (II) Open surgery with fast track perioperative treatment and Xelox chemotherapy; (III) Laparoscopic surgery with conventional perioperative treatment and mFolfox6 chemotherapy; (IV) Open surgery with conventional perioperative treatment and mFolfox6 chemotherapy. The primary endpoint of this study is the hospital stays. The secondary endpoints are the quality of life, chemotherapy related adverse events, surgical complications and hospitalization costs. Totally, 340 patients will be enrolled with 85 patients in each group. Conclusions The study initiates a new treatment model "Fast Track Multi-Discipline Treatment" for colorectal cancer, and will provide feasibility evidence on the new model "Fast Track Multi-Discipline Treatment" for patients with colorectal cancer. Trial registration ClinicalTrials.gov: NCT01080547 PMID:22111914
Zhou, Y; Mendonca, S C; Abel, G A; Hamilton, W; Walter, F M; Johnson, S; Shelton, J; Elliss-Brookes, L; McPhail, S; Lyratzopoulos, G
2018-01-01
Background: In England, ‘fast-track’ (also known as ‘two-week wait’) general practitioner referrals for suspected cancer in symptomatic patients are used to shorten diagnostic intervals and are supported by clinical guidelines. However, the use of the fast-track pathway may vary for different patient groups. Methods: We examined data from 669 220 patients with 35 cancers diagnosed in 2006–2010 following either fast-track or ‘routine’ primary-to-secondary care referrals using ‘Routes to Diagnosis’ data. We estimated the proportion of fast-track referrals by sociodemographic characteristic and cancer site and used logistic regression to estimate respective crude and adjusted odds ratios. We additionally explored whether sociodemographic associations varied by cancer. Results: There were large variations in the odds of fast-track referral by cancer (P<0.001). Patients with testicular and breast cancer were most likely to have been diagnosed after a fast-track referral (adjusted odds ratios 2.73 and 2.35, respectively, using rectal cancer as reference); whereas patients with brain cancer and leukaemias least likely (adjusted odds ratios 0.05 and 0.09, respectively, for brain cancer and acute myeloid leukaemia). There were sex, age and deprivation differences in the odds of fast-track referral (P<0.013) that varied in their size and direction for patients with different cancers (P<0.001). For example, fast-track referrals were least likely in younger women with endometrial cancer and in older men with testicular cancer. Conclusions: Fast-track referrals are less likely for cancers characterised by nonspecific presenting symptoms and patients belonging to low cancer incidence demographic groups. Interventions beyond clinical guidelines for ‘alarm’ symptoms are needed to improve diagnostic timeliness. PMID:29182609
NASA Astrophysics Data System (ADS)
Mor, Ilan; Vartsky, David; Dangendorf, Volker; Tittelmeier, Kai.; Weierganz, Mathias; Goldberg, Mark Benjamin; Bar, Doron; Brandis, Michal
2018-06-01
We describe an analysis procedure for automatic unambiguous detection of fast-neutron-induced recoil proton tracks in a micro-capillary array filled with organic liquid scintillator. The detector is viewed by an intensified CCD camera. This imaging neutron detector possesses the capability to perform high position-resolution (few tens of μm), energy-dispersive transmission-imaging using ns-pulsed beams. However, when operated with CW or DC beams, it also features medium-quality spectroscopic capabilities for incident neutrons in the energy range 2-20 MeV. In addition to the recoil proton events which display a continuous extended track structure, the raw images exhibit complex ion-tracks from nuclear interactions of fast-neutrons in the scintillator, capillaries quartz-matrix and CCD. Moreover, as expected, one also observes a multitude of isolated scintillation spots of varying intensity (henceforth denoted "blobs") that originate from several different sources, such as: fragmented proton tracks, gamma-rays, heavy-ion reactions as well as events and noise that occur in the image-intensifier and CCD. In order to identify the continuous-track recoil proton events and distinguish them from all these background events, a rapid, computerized and automatic track-recognition-procedure was developed. Based on an appropriately weighted analysis of track parameters such as: length, width, area and overall light intensity, the method is capable of distinguishing a single continuous-track recoil proton from typically surrounding several thousands of background events that are found in each CCD frame.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-04
... (Track I), providing fast examination for applicants desiring it, upon payment of the applicable fee and... examiners or supervisory patent examiners, specialized examiner training for fast track processing...
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2014 CFR
2014-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... merits based upon the pleadings; (3) The Commission may establish a hearing before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires...
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2013 CFR
2013-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... merits based upon the pleadings; (3) The Commission may establish a hearing before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires...
[Fast-track treatment--second revolution of colorectal surgery].
Kellokumpu, Ilmo
2012-01-01
The fast-track treatment model can be regarded as the second revolution of colorectal surgery after the introduction of laparoscopic surgery. In the gastro-surgical unit of the Central Hospital of Central Finland, results equivalent to international studies in colorectal surgery have been achieved by using fast-track model. In a study setting, this treatment model has resulted in significant decrease of total treatment costs and speeded up discharge of the patients from the hospital. The fast-track treatment model requires both a motivated, trained medical team and a motivated patient.
Fast Track: A Language Arts Program for Middle School Gifted
ERIC Educational Resources Information Center
Schneider, Jean
2008-01-01
"Fast Track" is a pseudonym for an accelerated, advanced language arts program for verbally gifted and high potential students in grades 6-8. The critical thinking model used for "Fast Track" was gleaned from Coalition of Essential Schools founder Ted Sizer's Habits of Mind: significance, evidence, connections, perspective, and supposition, as…
Aboyans, V; Lacroix, P; Jeannicot, A; Guilloux, J; Bertin, F; Laskar, M
2004-09-01
We assessed the usefulness of fast-track neck sonography with a new-generation hand-held ultrasound scanner in the detection of > or =60% carotid stenosis. Patients with a past history of atherosclerotic disease or presence of risk factors were enrolled. All had fast-track carotid screening with a hand-held ultrasound scanner. Initial assessment was performed with our quick imaging protocol. A second examiner performed a conventional complete carotid duplex as gold-standard. We enrolled 197 consecutive patients with a mean age of 67 years (range 35-94). A carotid stenosis >60% was detected in 13 cases (6%). The sensitivity, specificity, positive and negative predictive value of fast-track sonography was 100%, 64%, 17% and 100%, respectively. Concomitant power Doppler imaging during the fast-track method did not improve accuracy. The use of a fast-track method with a hand-held ultrasound device can reduce the number of unnecessary carotid Duplex and enhance the screening efficiency without missing significant carotid stenoses.
Liu, Xinyang; Plishker, William; Zaki, George; Kang, Sukryool; Kane, Timothy D.; Shekhar, Raj
2017-01-01
Purpose Common camera calibration methods employed in current laparoscopic augmented reality systems require the acquisition of multiple images of an entire checkerboard pattern from various poses. This lengthy procedure prevents performing laparoscope calibration in the operating room (OR). The purpose of this work was to develop a fast calibration method for electromagnetically (EM) tracked laparoscopes, such that calibration can be performed in the OR on demand. Methods We designed a mechanical tracking mount to uniquely and snugly position an EM sensor to an appropriate location on a conventional laparoscope. A tool named fCalib was developed to calibrate intrinsic camera parameters, distortion coefficients, and extrinsic parameters (transformation between the scope lens coordinate system and the EM sensor coordinate system) using a single image that shows an arbitrary portion of a special target pattern. For quick evaluation of calibration result in the OR, we integrated a tube phantom with fCalib and overlaid a virtual representation of the tube on the live video scene. Results We compared spatial target registration error between the common OpenCV method and the fCalib method in a laboratory setting. In addition, we compared the calibration re-projection error between the EM tracking-based fCalib and the optical tracking-based fCalib in a clinical setting. Our results suggested that the proposed method is comparable to the OpenCV method. However, changing the environment, e.g., inserting or removing surgical tools, would affect re-projection accuracy for the EM tracking-based approach. Computational time of the fCalib method averaged 14.0 s (range 3.5 s – 22.7 s). Conclusions We developed and validated a prototype for fast calibration and evaluation of EM tracked conventional (forward viewing) laparoscopes. The calibration method achieved acceptable accuracy and was relatively fast and easy to be performed in the OR on demand. PMID:27250853
Liu, Xinyang; Plishker, William; Zaki, George; Kang, Sukryool; Kane, Timothy D; Shekhar, Raj
2016-06-01
Common camera calibration methods employed in current laparoscopic augmented reality systems require the acquisition of multiple images of an entire checkerboard pattern from various poses. This lengthy procedure prevents performing laparoscope calibration in the operating room (OR). The purpose of this work was to develop a fast calibration method for electromagnetically (EM) tracked laparoscopes, such that the calibration can be performed in the OR on demand. We designed a mechanical tracking mount to uniquely and snugly position an EM sensor to an appropriate location on a conventional laparoscope. A tool named fCalib was developed to calibrate intrinsic camera parameters, distortion coefficients, and extrinsic parameters (transformation between the scope lens coordinate system and the EM sensor coordinate system) using a single image that shows an arbitrary portion of a special target pattern. For quick evaluation of calibration results in the OR, we integrated a tube phantom with fCalib prototype and overlaid a virtual representation of the tube on the live video scene. We compared spatial target registration error between the common OpenCV method and the fCalib method in a laboratory setting. In addition, we compared the calibration re-projection error between the EM tracking-based fCalib and the optical tracking-based fCalib in a clinical setting. Our results suggest that the proposed method is comparable to the OpenCV method. However, changing the environment, e.g., inserting or removing surgical tools, might affect re-projection accuracy for the EM tracking-based approach. Computational time of the fCalib method averaged 14.0 s (range 3.5 s-22.7 s). We developed and validated a prototype for fast calibration and evaluation of EM tracked conventional (forward viewing) laparoscopes. The calibration method achieved acceptable accuracy and was relatively fast and easy to be performed in the OR on demand.
Object tracking on mobile devices using binary descriptors
NASA Astrophysics Data System (ADS)
Savakis, Andreas; Quraishi, Mohammad Faiz; Minnehan, Breton
2015-03-01
With the growing ubiquity of mobile devices, advanced applications are relying on computer vision techniques to provide novel experiences for users. Currently, few tracking approaches take into consideration the resource constraints on mobile devices. Designing efficient tracking algorithms and optimizing performance for mobile devices can result in better and more efficient tracking for applications, such as augmented reality. In this paper, we use binary descriptors, including Fast Retina Keypoint (FREAK), Oriented FAST and Rotated BRIEF (ORB), Binary Robust Independent Features (BRIEF), and Binary Robust Invariant Scalable Keypoints (BRISK) to obtain real time tracking performance on mobile devices. We consider both Google's Android and Apple's iOS operating systems to implement our tracking approach. The Android implementation is done using Android's Native Development Kit (NDK), which gives the performance benefits of using native code as well as access to legacy libraries. The iOS implementation was created using both the native Objective-C and the C++ programing languages. We also introduce simplified versions of the BRIEF and BRISK descriptors that improve processing speed without compromising tracking accuracy.
Fast track lunar NTR systems assessment for the First Lunar Outpost and its evolvability to Mars
NASA Technical Reports Server (NTRS)
Borowski, Stanley K.; Alexander, Stephen W.
1992-01-01
The objectives of the 'fast track' lunar Nuclear Thermal Rocket (NTR) analysis are to quantify necessary engine/stage characteristics to perform NASA's 'First Lunar Outpost' scenario and to assess the potential for evolution to Mars mission applications. By developing NTR/stage technologies for use in NASA's 'First Lunar Outpost' scenario, NASA will make a major down payment on the key components needed for the follow-on Mars Space Transportation System. A faster, cheaper approach to overall lunar/Mars exploration is expected.
Fast calibration of electromagnetically tracked oblique-viewing rigid endoscopes.
Liu, Xinyang; Rice, Christina E; Shekhar, Raj
2017-10-01
The oblique-viewing (i.e., angled) rigid endoscope is a commonly used tool in conventional endoscopic surgeries. The relative rotation between its two moveable parts, the telescope and the camera head, creates a rotation offset between the actual and the projection of an object in the camera image. A calibration method tailored to compensate such offset is needed. We developed a fast calibration method for oblique-viewing rigid endoscopes suitable for clinical use. In contrast to prior approaches based on optical tracking, we used electromagnetic (EM) tracking as the external tracking hardware to improve compactness and practicality. Two EM sensors were mounted on the telescope and the camera head, respectively, with considerations to minimize EM tracking errors. Single-image calibration was incorporated into the method, and a sterilizable plate, laser-marked with the calibration pattern, was also developed. Furthermore, we proposed a general algorithm to estimate the rotation center in the camera image. Formulas for updating the camera matrix in terms of clockwise and counterclockwise rotations were also developed. The proposed calibration method was validated using a conventional [Formula: see text], 5-mm laparoscope. Freehand calibrations were performed using the proposed method, and the calibration time averaged 2 min and 8 s. The calibration accuracy was evaluated in a simulated clinical setting with several surgical tools present in the magnetic field of EM tracking. The root-mean-square re-projection error averaged 4.9 pixel (range 2.4-8.5 pixel, with image resolution of [Formula: see text] for rotation angles ranged from [Formula: see text] to [Formula: see text]. We developed a method for fast and accurate calibration of oblique-viewing rigid endoscopes. The method was also designed to be performed in the operating room and will therefore support clinical translation of many emerging endoscopic computer-assisted surgical systems.
Energy Dynamics: A Fast Track Inquiry
ERIC Educational Resources Information Center
Schmidt, Stan M.; Hrynyshyn, Alec
2004-01-01
Students investigate energy conversions by collaborating to develop a free standing track of plastic tubing through which a ball bearing moves at the fastest possible speed. Friendly competition leads to discussion of what worked and did not work and to the identification and investigation of underlying principles. (Contains 4 charts.)
Bounded tracking for nonminimum phase nonlinear systems with fast zero dynamics
DOT National Transportation Integrated Search
1996-12-01
A PostScript file. In this paper, tracking control laws for nonminimum phase nonlinear systems with both fast and slow, possibly unstable, zero dynamics are derived. The fast zero dynamics arise from a perturbation of a nominal system. These fast zer...
Anastasiadis, Kyriakos; Asteriou, Christos; Antonitsis, Polychronis; Argiriadou, Helena; Grosomanidis, Vassilios; Kyparissa, Magdalena; Deliopoulos, Apostolos; Konstantinou, Dimitrios; Tossios, Paschalis
2013-10-01
A minimal extracorporeal circulation (MECC) circuit integrates the advances in cardiopulmonary bypass (CPB) technology into a single circuit and is associated with improved short-term outcome. The aim of this study was to prospectively evaluate MECC compared with conventional CPB in facilitating fast-track recovery after elective coronary revascularization procedures. Prospective randomized study. All patients scheduled for elective coronary artery surgery were evaluated, excluding those considered particularly high risk for fast-track failure. The fast-track protocol included careful preoperative patient selection, a fast-track anesthetic technique based on minimal administration of fentanyl, surgery at normothermia, early postoperative extubation in the cardiac recovery unit, and admission to the cardiothoracic ward within the first 24 hours postoperatively. One hundred twenty patients were assigned randomly into 2 groups (60 in each group). Group A included patients who were operated on using the MECC circuit, whereas patients in Group B underwent surgery on conventional CPB. Incidence of fast-track recovery was significantly higher in patients undergoing MECC (25% v 6.7%, p = 0.006). MECC also was recognized as a strong independent predictor of early recovery, with an odds ratio of 3.8 (p = 0.011). Duration of mechanical ventilation and cardiac recovery unit stay were significantly lower in patients undergoing MECC together with the need for blood transfusion, duration of inotropic support, need for an intra-aortic balloon pump, and development of postoperative atrial fibrillation and renal failure. MECC promotes successful early recovery after elective coronary revascularization procedures, even in a nondedicated cardiac intensive care unit setting. Copyright © 2013 Elsevier Inc. All rights reserved.
Detection of Ballast Damage by In-Situ Vibration Measurement of Sleepers
NASA Astrophysics Data System (ADS)
Lam, H. F.; Wong, M. T.; Keefe, R. M.
2010-05-01
Ballasted track is one of the most important elements of railway transportation systems worldwide. Owing to its importance in railway safety, many monitoring and evaluation methods have been developed. Current railway track monitoring systems are comprehensive, fast and efficient in testing railway track level and alignment, rail gauge, rail corrugation, etc. However, the monitoring of ballast condition still relies very much on visual inspection and core tests. Although extensive research has been carried out in the development of non-destructive methods for ballast condition evaluation, a commonly accepted and cost-effective method is still in demand. In Hong Kong practice, if abnormal train vibration is reported by the train operator or passengers, permanent way inspectors will locate the problem area by track geometry measurement. It must be pointed out that visual inspection can only identify ballast damage on the track surface, the track geometry deficiencies and rail twists can be detected using a track gauge. Ballast damage under the sleeper loading area and the ballast shoulder, which are the main factors affecting track stability and ride quality, are extremely difficult if not impossible to be detected by visual inspection. Core test is a destructive test, which is expensive, time consuming and may be disruptive to traffic. A fast real-time ballast damage detection method that can be implemented by permanent way inspectors with simple equipment can certainly provide valuable information for engineers in assessing the safety and riding quality of ballasted track systems. The main objective of this paper is to study the feasibility in using the vibration characteristics of sleepers in quantifying the ballast condition under the sleepers, and so as to explore the possibility in developing a handy method for the detection of ballast damage based on the measured vibration of sleepers.
Restoring integrity--A grounded theory of coping with a fast track surgery programme.
Jørgensen, Lene Bastrup; Fridlund, Bengt
2016-01-01
The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. The study design used classical grounded theory. The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients' main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme.
Carré, Justin M; Iselin, Anne-Marie R; Welker, Keith M; Hariri, Ahmad R; Dodge, Kenneth A
2014-05-01
We tested the hypotheses that the Fast Track intervention program for high-risk children would reduce adult aggressive behavior and that this effect would be mediated by decreased testosterone responses to social provocation. Participants were a subsample of males from the full trial sample, who during kindergarten had been randomly assigned to the 10-year Fast Track intervention or to a control group. The Fast Track program attempted to develop children's social competencies through child social-cognitive and emotional-coping skills training, peer-relations coaching, academic tutoring, and classroom management, as well as training for parents to manage their child's behavior. At a mean age of 26 years, participants responded to laboratory provocations. Results indicated that, relative to control participants, men assigned to the intervention demonstrated reduced aggression and testosterone reactivity to social provocations. Moreover, reduced testosterone reactivity mediated the effect of intervention on aggressive behavior, which provides evidence for an enduring biological mechanism underlying the effect of early psychosocial intervention on aggressive behavior in adulthood.
Gunnarsdottir, Johanna; Bjornsdottir, Thorbjörg Edda; Halldorsson, Thorhallur Ingi; Halldorsdottir, Gudrun; Geirsson, Reynir Tomas
2011-07-01
To audit whether hospital stay shortened without increasing readmissions after implementation of fast-track methodology for elective cesarean section and characterize what influences length of stay. A fast-track program was initiated in November 2008, with a one year clinical audit and satisfaction survey. Discharge criteria were predefined and midwife home visits included if discharge was within 48 hours. Hospital stay by parity for women with elective section for singleton pregnancy between 1.11. 2008 - 31.10. 2009 (n=213, fast-track 182) was compared to 2003 (n=199) and 2007 (n=183). Readmissions and outpatient visits 2007 and 2008-9 were counted. Reasons for longer stay were recorded in fast-track, and body mass index. Median hospital stay decreased significantly from 81 to 52 hours between 2007 and 2008-9. Readmissions were four in each period and outpatient visit rates similar. In 2008-9, 66% of all women were discharged within 48 hours. Women in the fast-track program were satisfied with early discharge. Hospital stay for parous women was shorter in 2007 compared to 2003, but unchanged for nulliparas. Parity had a minimal influence on length of stay in 2008-9, although nulliparous women ≤ 25 years were more likely to stay >48 hours. Body mass index did not correlate with length of stay. Pain was rarely the reason for a longer stay in the fast-track program and 90% were satisfied with pain-medication after discharge. Most healthy women can be discharged early after singleton birth by elective cesarean, without increasing readmissions.
Restoring integrity—A grounded theory of coping with a fast track surgery programme
Jørgensen, Lene Bastrup; Fridlund, Bengt
2016-01-01
Aims and objectives The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Background Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. Design The study design used classical grounded theory. Methods The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Results Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients’ main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. Conclusion In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme. PMID:26751199
Fast-Track Management of Patients Undergoing Proximal Pancreatic Resection
French, JJ; Mansfield, SD; Jaques, K; Jaques, BC; Manas, DM; Charnley, RM
2009-01-01
INTRODUCTION To avoid the risk of complications of biliary drainage, a feasibility study was carried out to determine whether it might be possible to fast-track surgical treatment, with resection before biliary drainage, in jaundiced patients with proximal pancreatic/peri-ampullary malignancy. PATIENTS AND METHODS Over an 18-month period, based on their presenting bilirubin levels and other logistical factors, all jaundiced patients who might be suitable for fast-track management were identified. Data on complications and hospital stay were compared with those patients in whom a conventional pathway (with biliary drainage) was used during the same time period. Data were also compared with a group of patients from the preceding 6 months. RESULTS Nine patients were fast-tracked and 49 patients treated in the conventional pathway. Fast-track patients mean (SD) serum bilirubin level was 265 μmol/l (81.6) at the time of the operation compared to 43 μmol/l (51.3; P ≥ 0.0001) in conventional patients. Mean (SD) of time from referral to operation, 14 days (9) versus 59 days (36.9), was significantly shorter in fast-track patients than conventional patients (P ≤ 0.0001). Length of hospital stay mean (SD) at 17 (6) days versus 22 days (19.6; P = 0.2114), surgical complications and mortality in fast-track patients were similar to conventional patients. Prior to surgery, the 49 conventional patients underwent a total of 73 biliary drainage procedures resulting in seven major complications. Comparison with the group of patients from the previous 6 months indicated that the conventional group were not disadvantaged. CONCLUSIONS Fast-track management by resection without biliary drainage of selected patients with distal biliary strictures is safe and has the potential to reduce the waiting time to surgery, overall numbers of biliary drainage procedures and the complications thereof. PMID:19220943
FastSim: A Fast Simulation for the SuperB Detector
NASA Astrophysics Data System (ADS)
Andreassen, R.; Arnaud, N.; Brown, D. N.; Burmistrov, L.; Carlson, J.; Cheng, C.-h.; Di Simone, A.; Gaponenko, I.; Manoni, E.; Perez, A.; Rama, M.; Roberts, D.; Rotondo, M.; Simi, G.; Sokoloff, M.; Suzuki, A.; Walsh, J.
2011-12-01
We have developed a parameterized (fast) simulation for detector optimization and physics reach studies of the proposed SuperB Flavor Factory in Italy. Detector components are modeled as thin sections of planes, cylinders, disks or cones. Particle-material interactions are modeled using simplified cross-sections and formulas. Active detectors are modeled using parameterized response functions. Geometry and response parameters are configured using xml files with a custom-designed schema. Reconstruction algorithms adapted from BaBar are used to build tracks and clusters. Multiple sources of background signals can be merged with primary signals. Pattern recognition errors are modeled statistically by randomly misassigning nearby tracking hits. Standard BaBar analysis tuples are used as an event output. Hadronic B meson pair events can be simulated at roughly 10Hz.
Sustainable High-Potential Career Development: A Resource-Based View.
ERIC Educational Resources Information Center
Iles, Paul
1997-01-01
In the current economic climate, fast-track career models pose problems for individuals and organizations. An alternative model uses a resource-based view of the company and principles of sustainable development borrowed from environmentalism. (SK)
The value of materials R&D in the fast track development of fusion power
NASA Astrophysics Data System (ADS)
Ward, D. J.; Taylor, N. P.; Cook, I.
2007-08-01
The objective of the international fusion program is the creation of power plants with attractive safety and environmental features and viable economics. There is a range of possible plants that can meet these objectives, as studied for instance in the recent EU studies of power plant concepts. All of the concepts satisfy safety and environmental objectives but the economic performance is interpreted differently in different world regions according to the perception of future energy markets. This leads to different materials performance targets and the direction and timescales of the materials development programme needed to meet those targets. In this paper, the implications for materials requirements of a fast track approach to fusion development are investigated. This includes a quantification of the overall benefits of more advanced materials: including the effect of trading off an extended development time against a reduced cost of electricity for resulting power plants.
42 CFR 417.840 - Administrative review procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... fast-track appeals that affect its Medicare enrollees; and (b) Reconsiderations, hearings, Medicare Appeals Council review, and judicial review of the organization determinations and fast-track appeals...
42 CFR 417.840 - Administrative review procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... fast-track appeals that affect its Medicare enrollees; and (b) Reconsiderations, hearings, Medicare Appeals Council review, and judicial review of the organization determinations and fast-track appeals...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
Xu, Dong; Li, Jun; Song, Yongmao; Zhou, Jiaojiao; Sun, Fangfang; Wang, Jianwei; Duan, Yin; Hu, Yeting; Liu, Yue; Wang, Xiaochen; Sun, Lifeng; Wu, Linshan; Ding, Kefeng
2015-02-04
Many clinical trials had repeatedly shown that fast-track perioperative care and laparoscopic surgery are both preferred in the treatment of colorectal cancer. But few studies were designed to explore the diverse biochemical impacts of the two counterparts on human immunologic and nutritional status. Ninety-two cases of colorectal cancer patients meeting the inclusion criteria were randomized to four groups: laparoscopy with fast-track treatment (LAFT); open surgery with fast-track treatment (OSFT); laparoscopy with conventional treatment (LAC); open surgery with conventional treatment (OSC). Peripheral blood tests including nutritional factors (albumin, prealbumin, and transferrin), humoral immunologic factors (IgG, IgM, and IgA), and cellular immunologic factors (T and NK cells) were evaluated. Blood samples were collected preoperatively (baseline) and 12 and 96 h after surgery (indicated as POH12 and POH96, respectively). Albumin, transferrin, prealbumin, and IgG levels were the highest in the LAFT group for both POH12 and POH96 time intervals. Repeated measures (two-way ANOVA) indicated that the difference of albumin, transferrin, and IgG level were attributed to surgery type (P < 0.05) and not perioperative treatment (P > 0.05). Only in the laparoscopy-included groups, the relative albumin and IgG levels of POH96 were obviously higher than that of POH12. Laparoscopic surgery accelerated postoperative nutrition and immune levels rising again while fast-track treatment retarded the drop of postoperative nutrition and immune levels. Laparoscopic surgery might play a more important role than fast-track treatment in the earlier postoperative recovery of nutritional and immunologic status. Combined laparoscopic surgery with fast-track treatment provided best postoperative recovery of nutrition and immune status. These results should be further compared with the clinical outcomes of our FTMDT trial (clinicaltrials.gov: NCT01080547).
Patient experience in fast-track hip and knee arthroplasty--a qualitative study.
Specht, Kirsten; Kjaersgaard-Andersen, Per; Pedersen, Birthe D
2016-03-01
To explore the lived experience of patients in fast-track primary unilateral total hip and knee arthroplasty from the first visit at the outpatient clinic until discharge. Fast-track has resulted in increased effectiveness, including faster recovery and shorter length of stay to about two days after hip and knee arthroplasty. However, the patient perspective in fast-track with a median length of stay of less than three days has been less investigated. A qualitative design. A phenomenological-hermeneutic approach was used, inspired by Paul Ricoeur's theory of narrative and interpretation. Eight patients were included. Semi-structured interviews and participant observation were performed. Three themes emerged: dealing with pain; feelings of confidence or uncertainty - the meaning of information; and readiness for discharge. Generally, the patients were resistant to taking analgesics and found it difficult to find out when to take supplementary analgesics; therefore, nursing staff needed enough expertise to take responsibility. Factors that increased patients' confidence: information about fast-track, meeting staff before admission and involving relatives. In contrast, incorrect or conflicting information and a lack of respect for privacy led to uncertainty. In preparing for early discharge, sufficient pain management, feeling well-rested and optimal use of time during hospitalisation were important. The study shows the importance of dealing with pain and getting the right information and support to have confidence in the fast-track programme, to be ready for discharge and to manage postoperatively at home. In fast-track focusing on early discharge, there is an increased need for evidence-based nursing practice, including a qualified judgement of what is best for the patient in certain situations. The knowledge should be gleaned from: research; the patients' expertise, understanding and situation; and nurses' knowledge, skills and experience. © 2015 John Wiley & Sons Ltd.
DOT National Transportation Integrated Search
1978-07-01
This brochure describes the 22 test sections of the Federal Railroad Administration's FAST Track and the various track and mechanical measurements being made as of September 1977 - the end of the first year of operation at the facility. Because of th...
SU-F-T-370: A Fast Monte Carlo Dose Engine for Gamma Knife
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, T; Zhou, L; Li, Y
2016-06-15
Purpose: To develop a fast Monte Carlo dose calculation algorithm for Gamma Knife. Methods: To make the simulation more efficient, we implemented the track repeating technique on GPU. We first use EGSnrc to pre-calculate the photon and secondary electron tracks in water from two mono-energy photons of 60Co. The total photon mean free paths for different materials and energies are obtained from NIST. During simulation, each entire photon track was first loaded to shared memory for each block, the incident original photon was then splitted to Nthread sub-photons, each thread transport one sub-photon, the Russian roulette technique was applied formore » scattered and bremsstrahlung photons. The resultant electrons from photon interactions are simulated by repeating the recorded electron tracks. The electron step length is stretched/shrunk proportionally based on the local density and stopping power ratios of the local material. Energy deposition in a voxel is proportional to the fraction of the equivalent step length in that voxel. To evaluate its accuracy, dose deposition in a 300mm*300mm*300mm water phantom is calculated, and compared to EGSnrc results. Results: Both PDD and OAR showed great agreements (within 0.5%) between our dose engine result and the EGSnrc result. It only takes less than 1 min for every simulation, being reduced up to ∼40 times compared to EGSnrc simulations. Conclusion: We have successfully developed a fast Monte Carlo dose engine for Gamma Knife.« less
42 CFR 417.840 - Administrative review procedures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... determinations and fast-track appeals that affect its Medicare enrollees; and (b) Reconsiderations, hearings, Medicare Appeals Council review, and judicial review of the organization determinations and fast-track...
42 CFR 417.840 - Administrative review procedures.
Code of Federal Regulations, 2013 CFR
2013-10-01
... determinations and fast-track appeals that affect its Medicare enrollees; and (b) Reconsiderations, hearings, Medicare Appeals Council review, and judicial review of the organization determinations and fast-track...
42 CFR 417.840 - Administrative review procedures.
Code of Federal Regulations, 2014 CFR
2014-10-01
... determinations and fast-track appeals that affect its Medicare enrollees; and (b) Reconsiderations, hearings, Medicare Appeals Council review, and judicial review of the organization determinations and fast-track...
Patients' satisfaction with fast-track surgery in gynaecological oncology.
Philp, S; Carter, J; Pather, S; Barnett, C; D'Abrew, N; White, K
2015-07-01
This study investigates the experience and satisfaction with care of fast-tracked gynaecological patients. The Sydney Gynaecological Oncology Group, New South Wales, Australia, has previously shown the benefits of a fast-track surgery programme for gynaecology patients with both complex benign gynaecological pathology and gynaecological malignancy. The question of whether these benefits translate into a positive experience for fast-tracked patients, in the context of their hospital stay and healthcare team care, has not been previously explored in detail. A self-administered satisfaction questionnaire incorporating the European Organisation for Research and Treatment of Cancer (EORTC) cancer in-patient satisfaction with care measure (INPATSAT-32) questionnaire with additional questions was administered to 106 gynaecology participants at Royal Prince Alfred Hospital. Participants reported high levels of satisfaction with patient care and support received from doctors, ward nurses and the hospital as a service and care organisation, within the context of a fast-track surgical programme. Early hospital discharge after gynaecological surgery results in both enhanced recovery after surgery (ERAS) and high levels of patient satisfaction. © 2014 John Wiley & Sons Ltd.
X-33 Environmental Impact Statement: A Fast Track Approach
NASA Technical Reports Server (NTRS)
McCaleb, Rebecca C.; Holland, Donna L.
1998-01-01
NASA is required by the National Environmental Policy Act (NEPA) to prepare an appropriate level environmental analysis for its major projects. Development of the X-33 Technology Demonstrator and its associated flight test program required an environmental impact statement (EIS) under the NEPA. The EIS process is consists of four parts: the "Notice of Intent" to prepare an EIS and scoping; the draft EIS which is distributed for review and comment; the final ETS; and the "Record of Decision." Completion of this process normally takes from 2 - 3 years, depending on the complexity of the proposed action. Many of the agency's newest fast track, technology demonstration programs require NEPA documentation, but cannot sustain the lengthy time requirement between program concept development to implementation. Marshall Space Flight Center, in cooperation with Kennedy Space Center, accomplished the NEPA process for the X-33 Program in 13 months from Notice of Intent to Record of Decision. In addition, the environmental team implemented an extensive public involvement process, conducting a total of 23 public meetings for scoping and draft EIS comment along with numerous informal meetings with public officials, civic organizations, and Native American Indians. This paper will discuss the fast track approach used to successfully accomplish the NEPA process for X-33 on time.
Tracking Weight Change, Insulin Resistance, Stress, and Aerobic Fitness over 4 Years of College
ERIC Educational Resources Information Center
Hopper, Mari K.; Moninger, Shana Lynn
2017-01-01
Objective: To determine if weight gain is accompanied by development of insulin resistance (IR) during 4 years in college. Participants: Two cohorts of college students were enrolled in fall semesters 2009 and 2010 and tracked for 4 years. Methods: Following a 12-hour fast, subjects reported for measurement of body mass index (BMI), perceived…
A Fast MEANSHIFT Algorithm-Based Target Tracking System
Sun, Jian
2012-01-01
Tracking moving targets in complex scenes using an active video camera is a challenging task. Tracking accuracy and efficiency are two key yet generally incompatible aspects of a Target Tracking System (TTS). A compromise scheme will be studied in this paper. A fast mean-shift-based Target Tracking scheme is designed and realized, which is robust to partial occlusion and changes in object appearance. The physical simulation shows that the image signal processing speed is >50 frame/s. PMID:22969397
A high-speed tracking algorithm for dense granular media
NASA Astrophysics Data System (ADS)
Cerda, Mauricio; Navarro, Cristóbal A.; Silva, Juan; Waitukaitis, Scott R.; Mujica, Nicolás; Hitschfeld, Nancy
2018-06-01
Many fields of study, including medical imaging, granular physics, colloidal physics, and active matter, require the precise identification and tracking of particle-like objects in images. While many algorithms exist to track particles in diffuse conditions, these often perform poorly when particles are densely packed together-as in, for example, solid-like systems of granular materials. Incorrect particle identification can have significant effects on the calculation of physical quantities, which makes the development of more precise and faster tracking algorithms a worthwhile endeavor. In this work, we present a new tracking algorithm to identify particles in dense systems that is both highly accurate and fast. We demonstrate the efficacy of our approach by analyzing images of dense, solid-state granular media, where we achieve an identification error of 5% in the worst evaluated cases. Going further, we propose a parallelization strategy for our algorithm using a GPU, which results in a speedup of up to 10 × when compared to a sequential CPU implementation in C and up to 40 × when compared to the reference MATLAB library widely used for particle tracking. Our results extend the capabilities of state-of-the-art particle tracking methods by allowing fast, high-fidelity detection in dense media at high resolutions.
78 FR 33836 - CPSC Safety Academy
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-05
... compliance issues, and the fast track recall program. The Safety Academy is structured such that the morning... continued, including Fast Track and Section 15; and (Panel 3) Flammable Fabrics, Drawstrings, and Sleepwear...
Motion-Blur-Free High-Speed Video Shooting Using a Resonant Mirror
Inoue, Michiaki; Gu, Qingyi; Takaki, Takeshi; Ishii, Idaku; Tajima, Kenji
2017-01-01
This study proposes a novel concept of actuator-driven frame-by-frame intermittent tracking for motion-blur-free video shooting of fast-moving objects. The camera frame and shutter timings are controlled for motion blur reduction in synchronization with a free-vibration-type actuator vibrating with a large amplitude at hundreds of hertz so that motion blur can be significantly reduced in free-viewpoint high-frame-rate video shooting for fast-moving objects by deriving the maximum performance of the actuator. We develop a prototype of a motion-blur-free video shooting system by implementing our frame-by-frame intermittent tracking algorithm on a high-speed video camera system with a resonant mirror vibrating at 750 Hz. It can capture 1024 × 1024 images of fast-moving objects at 750 fps with an exposure time of 0.33 ms without motion blur. Several experimental results for fast-moving objects verify that our proposed method can reduce image degradation from motion blur without decreasing the camera exposure time. PMID:29109385
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2012 CFR
2012-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2010 CFR
2010-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2013 CFR
2013-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2014 CFR
2014-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2011 CFR
2011-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
77 FR 48506 - CPSC Safety Academy
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-14
... issues and the Fast-Track process. These discussions will be held in a panel format, with a brief... Nuances of 6b''; or ``Fast-Track Process--Compliance.'' An official of the General Administration of...
Zoremba, Martin; Kratz, Thomas; Dette, Frank; Wulf, Hinnerk; Steinfeldt, Thorsten; Wiesmann, Thomas
2015-01-01
After shoulder surgery performed in patients with interscalene nerve block (without general anesthesia), fast track capability and postoperative pain management in the PACU are improved compared with general anesthesia alone. However, it is not known if these evidence-based benefits still exist when the interscalene block is combined with general anesthesia. We retrospectively analyzed a prospective cohort data set of 159 patients undergoing shoulder arthroscopy with general anesthesia alone (n = 60) or combined with an interscalene nerve block catheter (n = 99) for fast track capability time. Moreover, comparisons were made for VAS scores, analgesic consumption in the PACU, pain management, and lung function measurements. The groups did not differ in mean time to fast track capability (22 versus 22 min). Opioid consumption in PACU was significantly less in the interscalene group, who had significantly better VAS scores during PACU stay. Patients receiving interscalene blockade had a significantly impaired lung function postoperatively, although this did not affect postoperative recovery and had no impact on PACU times. The addition of interscalene block to general anesthesia for shoulder arthroscopy did not enhance fast track capability. Pain management and VAS scores were improved in the interscalene nerve block group.
NASA Astrophysics Data System (ADS)
Sutcliffe, G. D.; Milanese, L. M.; Orozco, D.; Lahmann, B.; Gatu Johnson, M.; Séguin, F. H.; Sio, H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D.; Park, H.-S.; Rygg, J. R.; Casey, D. T.; Bionta, R.; Turnbull, D. P.; Huntington, C. M.; Ross, J. S.; Zylstra, A. B.; Rosenberg, M. J.; Glebov, V. Yu.
2016-11-01
CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.
Sutcliffe, G D; Milanese, L M; Orozco, D; Lahmann, B; Gatu Johnson, M; Séguin, F H; Sio, H; Frenje, J A; Li, C K; Petrasso, R D; Park, H-S; Rygg, J R; Casey, D T; Bionta, R; Turnbull, D P; Huntington, C M; Ross, J S; Zylstra, A B; Rosenberg, M J; Glebov, V Yu
2016-11-01
CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.
Design of a Holonic Control Architecture for Distributed Sensor Management
2009-09-01
Tracking tasks require only intermit - tent access to the sensors to maintain a given track quality. The higher the specified quality, the more often...resolution of the sensor (i.e., sensor mode), which can be adjusted to compensate for fast moving targets tracked over long ranges, or slower moving...but provides higher data update rates that are beneficial when tracking fast agile targets (i.e., a fighter). Table A.2 illustrates the dependence of
Tsilimparis, N; Haase, O; Wendling, P; Kipfmüller, K; Schmid, M; Engemann, R; Schwenk, W
2010-09-01
The natural course of sigmoid colon diverticulitis during conservative therapy and the assessment of the perioperative morbidity after sigmoid colon resection are differently evaluated by surgeons and gastroenterologists. The "fast-track" rehabilitation accelerates the reconvalescence and reduces the rate of postoperative general complications after colorectal surgery. The results of the laparoscopic "Fast-track" sigmoidectomy should be examined within a quality assurance program to better evaluate the perioperative risks following surgical management of diverticulitis. A prospective data collection within the voluntary quality assurance program "fast-track" Kolon II was performed. All participating clinics agreed on a multimodal, evidence-based standard perioperative treatment in terms of a "fast-track" rehabilitation for elective operations for sigmoid diverticulitis. Data from 846 patients undergoing laparoscopic "fast-track" sigmoid colon resection in 23 surgical departments in Germany were collected and evaluated. The mean age of the patients was 63 years (range 23 - 91). 203 patients (24 %) had severe co-morbidities (ASA classification III - IV). A conversion to conventional open surgery was necessary in 51 cases (6 %). Complications occurred in 93 patients (11 %). 76 patients suffered a surgical complication (8.9 %) and 32 patients (3.8 %) a general complication. Two patients died postoperatively due to multi-organ failure following anastomotic leaks. The patients took solid food in median on day 1 after surgery (range, 0 - 5) and passed stool on day 2 (range, 0 - 22). Predefined discharge criteria (free of pain on oral medication, normal oral feeding, stool) were met on day 4 (range, 1 - 58) and the patients were discharged on day 7 (range, 3 - 72). The 30-day re-admission rate was 3.9 %. Patients undergoing laparoscopic "fast-track" sigmoidectomy had a low rate of general complications and had a rapid reconvalescence with a short postoperative in-patient treatment as documented in a german quality assurance program. Copyright Georg Thieme Verlag KG Stuttgart . New York.
Park, J H; Garipov, G K; Jeon, J A; Khrenov, B A; Kim, J E; Kim, M; Kim, Y K; Lee, C-H; Lee, J; Na, G W; Nam, S; Park, I H; Park, Y-S
2008-12-08
We introduce a novel telescope consisting of a pinhole-like camera with rotatable MEMS micromirrors substituting for pinholes. The design is ideal for observations of transient luminous phenomena or fast-moving objects, such as upper atmospheric lightning and bright gamma ray bursts. The advantage of the MEMS "obscura telescope" over conventional cameras is that it is capable both of searching for events over a wide field of view, and fast zooming to allow detailed investigation of the structure of events. It is also able to track the triggering object to investigate its space-time development, and to center the interesting portion of the image on the photodetector array. We present the proposed system and the test results for the MEMS obscura telescope which has a field of view of 11.3 degrees, sixteen times zoom-in and tracking within 1 ms. (c) 2008 Optical Society of America
Assessment of the high temperature fission chamber technology for the French fast reactor program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jammes, C.; Filliatre, P.; Geslot, B.
2011-07-01
High temperature fission chambers are key instruments for the control and protection of the sodium-cooled fast reactor. First, the developments of those neutron detectors, which are carried out either in France or abroad are reviewed. Second, the French realizations are assessed with the use of the technology readiness levels in order to identify tracks of improvement. (authors)
The yield of colorectal cancer among fast track patients with normocytic and microcytic anaemia.
Panagiotopoulou, I G; Fitzrol, D; Parker, R A; Kuzhively, J; Luscombe, N; Wells, A D; Menon, M; Bajwa, F M; Watson, M A
2014-05-01
We receive fast track referrals on the basis of iron deficiency anaemia (IDA) for patients with normocytic anaemia or for patients with no iron studies. This study examined the yield of colorectal cancer (CRC) among fast track patients to ascertain whether awaiting confirmation of IDA is necessary prior to performing bowel investigations. A review was undertaken of 321 and 930 consecutive fast track referrals from Centre A and Centre B respectively. Contingency tables were analysed using Fisher's exact test. Logistic regression analyses were performed to investigate significant predictors of CRC. Overall, 229 patients were included from Centre A and 689 from Centre B. The odds ratio for microcytic anaemia versus normocytic anaemia in the outcome of CRC was 1.3 (95% confidence interval [CI]: 0.5-3.9) for Centre A and 1.6 (95% CI: 0.8-3.3) for Centre B. In a logistic regression analysis (Centre B only), no significant difference in CRC rates was seen between microcytic and normocytic anaemia (adjusted odds ratio: 1.9, 95% CI: 0.9-3.9). There was no statistically significant difference in the yield of CRC between microcytic and normocytic anaemia (p=0.515, Fisher's exact test) in patients with anaemia only and no colorectal symptoms. Finally, CRC cases were seen in both microcytic and normocytic groups with or without low ferritin. There is no significant difference in the yield of CRC between fast track patients with microcytic and normocytic anaemia. This study provides insufficient evidence to support awaiting confirmation of IDA in fast track patients with normocytic anaemia prior to requesting bowel investigations.
78 FR 52166 - Quantitative Messaging Research
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-22
... COMMODITY FUTURES TRADING COMMISSION Quantitative Messaging Research AGENCY: Commodity Futures... survey will follow qualitative message testing research (for which CFTC received fast-track OMB approval... message testing research (for which CFTC received fast-track OMB approval) and is necessary to identify...
First results of the silicon telescope using an 'artificial retina' for fast track finding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neri, N.; Abba, A.; Caponio, F.
We present the first results of the prototype of a silicon tracker with trigger capabilities based on a novel approach for fast track finding. The working principle of the 'artificial retina' is inspired by the processing of visual images by the brain and it is based on extensive parallelization of data distribution and pattern recognition. The algorithm has been implemented in commercial FPGAs in three main logic modules: a switch for the routing of the detector hits, a pool of engines for the digital processing of the hits, and a block for the calculation of the track parameters. The architecturemore » is fully pipelined and allows the reconstruction of real-time tracks with a latency less then 100 clock cycles, corresponding to 0.25 microsecond at 400 MHz clock. The silicon telescope consists of 8 layers of single-sided silicon strip detectors with 512 strips each. The detector size is about 10 cm x 10 cm and the strip pitch is 183 μm. The detectors are read out by the Beetle chip, a custom ASICs developed for LHCb, which provides the measurement of the hit position and pulse height of 128 channels. The 'artificial retina' algorithm has been implemented on custom data acquisition boards based on FPGAs Xilinx Kintex 7 lx160. The parameters of the tracks detected are finally transferred to host PC via USB 3.0. The boards manage the read-out ASICs and the sampling of the analog channels. The read-out is performed at 40 MHz on 4 channels for each ASIC that corresponds to a decoding of the telescope information at 1.1 MHz. We report on the first results of the fast tracking device and compare with simulations. (authors)« less
A Fast Track approach to deal with the temporal dimension of crop water footprint
NASA Astrophysics Data System (ADS)
Tuninetti, Marta; Tamea, Stefania; Laio, Francesco; Ridolfi, Luca
2017-07-01
Population growth, socio-economic development and climate changes are placing increasing pressure on water resources. Crop water footprint is a key indicator in the quantification of such pressure. It is determined by crop evapotranspiration and crop yield, which can be highly variable in space and time. While the spatial variability of crop water footprint has been the objective of several investigations, the temporal variability remains poorly studied. In particular, some studies approached this issue by associating the time variability of crop water footprint only to yield changes, while considering evapotranspiration patterns as marginal. Validation of this Fast Track approach has yet to be provided. In this Letter we demonstrate its feasibility through a comprehensive validation, an assessment of its uncertainty, and an example of application. Our results show that the water footprint changes are mainly driven by yield trends, while evapotranspiration plays a minor role. The error due to considering constant evapotranspiration is three times smaller than the uncertainty of the model used to compute the crop water footprint. These results confirm the suitability of the Fast Track approach and enable a simple, yet appropriate, evaluation of time-varying crop water footprint.
Albert, Dustin; Belsky, Daniel W.; Crowley, D. Max; Latendresse, Shawn J.; Aliev, Fazil; Riley, Brien; Sun, Cuie; Dick, Danielle M.; Dodge, Kenneth R.
2014-01-01
Early interventions are a preferred method for addressing behavioral problems in high-risk children, but often have only modest effects. Identifying sources of variation in intervention effects can suggest means to improve efficiency. One potential source of such variation is the genome. We conducted a genetic analysis of the Fast Track Randomized Control Trial, a 10-year-long intervention to prevent high-risk kindergarteners from developing adult externalizing problems including substance abuse and antisocial behavior. We tested whether variants of the glucocorticoid receptor gene NR3C1 were associated with differences in response to the Fast Track intervention. We found that in European-American children, a variant of NR3C1 identified by the single-nucleotide polymorphism rs10482672 was associated with increased risk for externalizing psychopathology in control group children and decreased risk for externalizing psychopathology in intervention group children. Variation in NR3C1 measured in this study was not associated with differential intervention response in African-American children. We discuss implications for efforts to prevent externalizing problems in high-risk children and for public policy in the genomic era. PMID:26106668
A fast method for optical simulation of flood maps of light-sharing detector modules.
Shi, Han; Du, Dong; Xu, JianFeng; Moses, William W; Peng, Qiyu
2015-12-01
Optical simulation of the detector module level is highly desired for Position Emission Tomography (PET) system design. Commonly used simulation toolkits such as GATE are not efficient in the optical simulation of detector modules with complicated light-sharing configurations, where a vast amount of photons need to be tracked. We present a fast approach based on a simplified specular reflectance model and a structured light-tracking algorithm to speed up the photon tracking in detector modules constructed with polished finish and specular reflector materials. We simulated conventional block detector designs with different slotted light guide patterns using the new approach and compared the outcomes with those from GATE simulations. While the two approaches generated comparable flood maps, the new approach was more than 200-600 times faster. The new approach has also been validated by constructing a prototype detector and comparing the simulated flood map with the experimental flood map. The experimental flood map has nearly uniformly distributed spots similar to those in the simulated flood map. In conclusion, the new approach provides a fast and reliable simulation tool for assisting in the development of light-sharing-based detector modules with a polished surface finish and using specular reflector materials.
Track reconstruction in the emulsion-lead target of the OPERA experiment using the ESS microscope
NASA Astrophysics Data System (ADS)
Arrabito, L.; Bozza, C.; Buontempo, S.; Consiglio, L.; Cozzi, M.; D'Ambrosio, N.; DeLellis, G.; DeSerio, M.; Di Capua, F.; Di Ferdinando, D.; Di Marco, N.; Ereditato, A.; Esposito, L. S.; Fini, R. A.; Giacomelli, G.; Giorgini, M.; Grella, G.; Ieva, M.; Janicsko Csathy, J.; Juget, F.; Kreslo, I.; Laktineh, I.; Manai, K.; Mandrioli, G.; Marotta, A.; Migliozzi, P.; Monacelli, P.; Moser, U.; Muciaccia, M. T.; Pastore, A.; Patrizii, L.; Petukhov, Y.; Pistillo, C.; Pozzato, M.; Romano, G.; Rosa, G.; Russo, A.; Savvinov, N.; Schembri, A.; Scotto Lavina, L.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Strolin, P.; Tioukov, V.; Waelchli, T.
2007-05-01
The OPERA experiment, designed to conclusively prove the existence of νμ→ντ oscillations in the atmospheric sector, makes use of a massive lead-nuclear emulsion target to observe the appearance of ντ's in the CNGS νμ beam. The location and analysis of the neutrino interactions in quasi real-time required the development of fast computer-controlled microscopes able to reconstruct particle tracks with sub-micron precision and high efficiency at a speed of ~20 cm2/h. This paper describes the performance in particle track reconstruction of the European Scanning System, a novel automatic microscope for the measurement of emulsion films developed for OPERA.
42 CFR 422.624 - Notifying enrollees of termination of provider services.
Code of Federal Regulations, 2012 CFR
2012-10-01
... begins. (iii) A description of the enrollee's right to a fast-track appeal under § 422.626, including... procedures if the enrollee fails to meet the deadline for a fast-track IRE appeal. (iv) The enrollee's right...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-23
.... 1660-NEW; FEMA Form 089-4, TSGP Investment Justification; FEMA Form 089-27, Fast Track Cost Training...-27, Fast Track Cost Training Matrix. Abstract: The TSGP is an important component of the Department...
42 CFR 422.624 - Notifying enrollees of termination of provider services.
Code of Federal Regulations, 2013 CFR
2013-10-01
... begins. (iii) A description of the enrollee's right to a fast-track appeal under § 422.626, including... procedures if the enrollee fails to meet the deadline for a fast-track IRE appeal. (iv) The enrollee's right...
42 CFR 422.624 - Notifying enrollees of termination of provider services.
Code of Federal Regulations, 2011 CFR
2011-10-01
... begins. (iii) A description of the enrollee's right to a fast-track appeal under § 422.626, including... procedures if the enrollee fails to meet the deadline for a fast-track IRE appeal. (iv) The enrollee's right...
42 CFR 422.624 - Notifying enrollees of termination of provider services.
Code of Federal Regulations, 2010 CFR
2010-10-01
... begins. (iii) A description of the enrollee's right to a fast-track appeal under § 422.626, including... procedures if the enrollee fails to meet the deadline for a fast-track IRE appeal. (iv) The enrollee's right...
42 CFR 422.624 - Notifying enrollees of termination of provider services.
Code of Federal Regulations, 2014 CFR
2014-10-01
... begins. (iii) A description of the enrollee's right to a fast-track appeal under § 422.626, including... procedures if the enrollee fails to meet the deadline for a fast-track IRE appeal. (iv) The enrollee's right...
The Fleet Application for Scheduling and Tracking (FAST) Management Website
NASA Technical Reports Server (NTRS)
Marrero-Perez, Radames J.
2014-01-01
The FAST application was designed to replace the paper and pen method of checking out and checking in GSA Vehicles at KSC. By innovating from a paper and pen based checkout system to a fully digital one, not only the resources wasted by printing the checkout forms have been reduced, but it also reduces significantly the time that users and fleet managers need to interact with the system as well as improving the record accuracy for each vehicle. The vehicle information is pulled from a centralized database server in the SPSDL. In an attempt to add a new feature to the FAST application, the author of this report (alongside the FAST developers) has been designing and developing the FAST Management Website. The GSA fleet managers had to rely on the FAST developers in order to add new vehicles, edit vehicles and previous transactions, or for generating vehicles reports. By providing an easy-to-use FAST Management Website portal, the GSA fleet managers are now able to easily move vehicles, edit records, and print reports.
Fast-Track Teacher Recruitment.
ERIC Educational Resources Information Center
Grant, Franklin Dean
2001-01-01
Schools need a Renaissance human-resources director to implement strategic staffing and fast-track teacher-recruitment plans. The HR director must attend to customer satisfaction, candidate supply, web-based recruitment possibilities, stabilization of newly hired staff, retention of veteran staff, utilization of retired employees, and latest…
Fast-Track Cleanup at Closing DoD Installations
The Fast-Track Cleanup program strives to make parcels available for reuse as quickly as possible by the transfer of uncontaminated or remediated parcels, the lease of contaminated parcels where cleanup is underway, or the 'early transfer' of contaminated property undergoing cleanup.
van Harten, W H; Goedbloed, N; Boekhout, A H; Heintzbergen, S
2018-02-07
In general, patients with a cancer suspicion visit the hospital multiple times before diagnosis is completed. Using various "operations management" techniques a few fast track diagnostic services were implemented in the Netherlands Cancer Institute (NKI) in 2006. Growing patient numbers and increasing process complexity, led to diminished service levels. To decrease the amount of patient visits and to extend these services beyond the (obvious) breast cancer services, fast track diagnostics is now implemented for all 18 cancer types that present with a frequency of minimally one per week. The throughput time (first visit to diagnosis conversation) was measured before, and after implementation of fast track diagnostics. The process was redesigned closely involving the multidisciplinary teams. In an eclectic approach elements from lean management, theory of constraints and mathematical analysis were used to organize slots per tumor type for MRI, CT, PET and echography. A post measurement was performed after 3 and 6 months. In pre measurement access time was calculated to be 10 to 15 workdays, mean throughput time was 6.0 workdays. It proved possible to design the process of 18 tumors as a fast track, of which 7 as "one stop shop" (diagnosis completed in one visit). Involvement of clinical- and board leadership, massive communication efforts and commitment of physicians to reschedule their work proved decisive. After 3 and 6 months of implementation, the mean access time was 8.2 and 8.7 workdays respectively and mean throughput time was 3.4 and 3.3 workdays respectively. Throughput- and access time were considerably shortened after implementation of fast track diagnostics for 18 cancer types. The involvement of physicians in reorganizing their work and rapid responding to their needs during the implementation phase were a crucial success factor.
Fast Track Extubation In Adult Patients On Pump Open Heart Surgery At A Tertiary Care Hospital.
Akhtar, Mohammad Irfan; Sharif, Hasanat; Hamid, Mohammad; Samad, Khalid; Khan, Fazal Hameed
2016-01-01
Fast-track cardiac surgery programs have been established as the standard of cardiac surgical care. Studies have shown that early extubation in elective cardiac surgery patients, including coronary and non-coronary open-heart surgery patients does not increase perioperative morbidity and mortality. The objective of this observational study was to determine the success and failure profile of fast track extubation (FTE) practice in adult open-heart surgical patients. The study was conducted at cardiac operating room and Cardiac Intensive Care Unit (CICU) of a tertiary care hospital for a period of nine months, i.e., from Oct 2014 to June-2015. All on pump elective adult cardiac surgery patients including isolated CABG, isolated Valve replacements, combined procedures and aortic root replacements were enrolled in the study. Standardized anesthetic technique was adopted. Surgical and bypass techniques were tailored according to the procedure. Success of Fast track extubation was defined as extubation within 6 hours of arrival in CICU. A total of 290 patients were recruited. The average age of the patients was 56.3±10.5 years. There were 77.6% male and 22.4% female patients. Overall success rate was 51.9% and failure rate was 48.1%. The peri-operative renal insufficiency, cross clamp time and CICU stay (hours) were significantly lower in success group. Re-intubation rate was 0.74%. The perioperative parameters were significantly better in success group and the safety was also demonstrated in the patients who were fast tracked successfully. To implement the practice in its full capacity and benefit, a fast track protocol needs to be devised to standardize the current practices and to disseminate the strategy among junior anaesthesiologists, perfusionists and nursing staff.
Stover, John; Bollinger, Lori; Izazola, Jose Antonio; Loures, Luiz; DeLay, Paul; Ghys, Peter D
2016-01-01
In 2011 a new Investment Framework was proposed that described how the scale-up of key HIV interventions could dramatically reduce new HIV infections and AIDS-related deaths in low and middle income countries by 2015. This framework included ambitious coverage goals for prevention and treatment services for 2015, resulting in a reduction of new HIV infections by more than half, in line with the goals of the declaration of the UN High Level Meeting in June 2011. However, the approach suggested a leveling in the number of new infections at about 1 million annually-far from the UNAIDS goal of ending AIDS by 2030. In response, UNAIDS has developed the Fast-Track approach that is intended to provide a roadmap to the actions required to achieve this goal. The Fast-Track approach is predicated on a rapid scale-up of focused, effective prevention and treatment services over the next 5 years and then maintaining a high level of programme implementation until 2030. Fast-Track aims to reduce new infections and AIDS-related deaths by 90% from 2010 to 2030 and proposes a set of biomedical, behavioral and enabling intervention targets for 2020 and 2030 to achieve that goal, including the rapid scale-up initiative for antiretroviral treatment known as 90-90-90. Compared to a counterfactual scenario of constant coverage for all services at early-2015 levels, the Fast-Track approach would avert 18 million HIV infections and 11 million deaths from 2016 to 2030 globally. This paper describes the analysis that produced these targets and the estimated resources needed to achieve them in low- and middle-income countries. It indicates that it is possible to achieve these goals with a significant push to achieve rapid scale-up of key interventions between now and 2020. The annual resources required from all sources would rise to US$7.4Bn in low-income countries, US$8.2Bn in lower middle-income countries and US$10.5Bn in upper-middle-income-countries by 2020 before declining approximately 9% by 2030.
Secure FAST: Security Enhancement in the NATO Time Sensitive Targeting Tool
2010-11-01
designed to aid in the tracking and prosecuting of Time Sensitive Targets. The FAST tool provides user level authentication and authorisation in terms...level authentication and authorisation in terms of security. It uses operating system level security but does not provide application level security for...and collaboration tool, designed to aid in the tracking and prosecuting of Time Sensitive Targets. The FAST tool provides user level authentication and
Fast-track program vs traditional care in surgery for gastric cancer.
Chen, Zhi-Xing; Liu, Ae-Huey Jennifer; Cen, Ying
2014-01-14
To systematically review the evidence for the effectiveness of fast-track program vs traditional care in laparoscopic or open surgery for gastric cancer. PubMed, Embase and the Cochrane library databases were electronically searched for published studies between January 1995 and April 2013, and only randomized trials were included. The references of relevant studies were manually searched for further studies that may have been missed. Search terms included "gastric cancer", "fast track" and "enhanced recovery". Five outcome variables were considered most suitable for analysis: postoperative hospital stay, medical cost, duration to first flatus, C-reactive protein (CRP) level and complications. Postoperative hospital stay was calculated from the date of operation to the date of discharge. Fixed effects model was used for meta-analysis. Compared with traditional care, fast-track program could significantly decrease the postoperative hospital stay [weighted mean difference (WMD) = -1.19, 95%CI: -1.79--0.60, P = 0.0001, fixed model], duration to first flatus (WMD = -6.82, 95%CI: -11.51--2.13, P = 0.004), medical costs (WMD = -2590, 95%CI: -4054--1126, P = 0.001), and the level of CRP (WMD = -17.78, 95%CI: -32.22--3.35, P = 0.0001) in laparoscopic surgery for gastric cancer. In open surgery for gastric cancer, fast-track program could also significantly decrease the postoperative hospital stay (WMD = -1.99, 95%CI: -2.09--1.89, P = 0.0001), duration to first flatus (WMD = -12.0, 95%CI: -18.89--5.11, P = 0.001), medical cost (WMD = -3674, 95%CI: -5025--2323, P = 0.0001), and the level of CRP (WMD = -27.34, 95%CI: -35.42--19.26, P = 0.0001). Furthermore, fast-track program did not significantly increase the incidence of complication (RR = 1.39, 95%CI: 0.77-2.51, P = 0.27, for laparoscopic surgery; and RR = 1.52, 95%CI: 0.90-2.56, P = 0.12, for open surgery). Our overall results suggested that compared with traditional care, fast-track program could result in shorter postoperative hospital stay, less medical costs, and lower level of CRP, with no more complications occurring in both laparoscopic and open surgery for gastric cancer.
A-Track: A new approach for detection of moving objects in FITS images
NASA Astrophysics Data System (ADS)
Atay, T.; Kaplan, M.; Kilic, Y.; Karapinar, N.
2016-10-01
We have developed a fast, open-source, cross-platform pipeline, called A-Track, for detecting the moving objects (asteroids and comets) in sequential telescope images in FITS format. The pipeline is coded in Python 3. The moving objects are detected using a modified line detection algorithm, called MILD. We tested the pipeline on astronomical data acquired by an SI-1100 CCD with a 1-meter telescope. We found that A-Track performs very well in terms of detection efficiency, stability, and processing time. The code is hosted on GitHub under the GNU GPL v3 license.
Fast track surgery: a clinical audit.
Carter, Jonathan; Szabo, Rebecca; Sim, Wee Wee; Pather, Selvan; Philp, Shannon; Nattress, Kath; Cotterell, Stephen; Patel, Pinki; Dalrymple, Chris
2010-04-01
Fast track surgery is a concept that utilises a variety of techniques to reduce the surgical stress response, allowing a shortened length of stay, improved outcomes and decreased time to full recovery. To evaluate a peri-operative Fast Track Surgical Protocol (FTSP) in patients referred for abdominal surgery. All patients undergoing a laparotomy over a 12-month period were entered prospectively on a clinical database. Data were retrospectively analysed. Over the study period, 72 patients underwent a laparotomy. Average patient age was 54 years and average weight and BMI were 67.2 kg and 26 respectively. Sixty three (88%) patients had a vertical midline incision (VMI). There were no intraoperative blood transfusions. The median length of stay (LOS) was 3.0 days. Thirty eight patients (53%) were discharged on or before post op day 3, seven (10%) of whom were discharged on postoperative day 2. On stepwise regression analysis, the following were found to be independently associated with reduced LOS: able to tolerate early enteral nutrition, good performance status, use of COX inhibitor and transverse incision. In comparison with colleagues at the SGOG not undertaking FTS for their patients, the authors' LOS was lower and the RANZCOG modified Quality Indicators (QI's) did not demonstrate excess morbidity. Patients undergoing fast track surgery can be discharged from hospital with a reduced LOS, without an increased readmission rate and with comparative outcomes to non-fast tracked patients.
Sutcliffe, G. D.; Milanese, L. M.; Orozco, D.; ...
2016-08-05
CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint ofmore » the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.« less
NASA Astrophysics Data System (ADS)
Yang, Xinxin; Ge, Shuzhi Sam; He, Wei
2018-04-01
In this paper, both the closed-form dynamics and adaptive robust tracking control of a space robot with two-link flexible manipulators under unknown disturbances are developed. The dynamic model of the system is described with assumed modes approach and Lagrangian method. The flexible manipulators are represented as Euler-Bernoulli beams. Based on singular perturbation technique, the displacements/joint angles and flexible modes are modelled as slow and fast variables, respectively. A sliding mode control is designed for trajectories tracking of the slow subsystem under unknown but bounded disturbances, and an adaptive sliding mode control is derived for slow subsystem under unknown slowly time-varying disturbances. An optimal linear quadratic regulator method is proposed for the fast subsystem to damp out the vibrations of the flexible manipulators. Theoretical analysis validates the stability of the proposed composite controller. Numerical simulation results demonstrate the performance of the closed-loop flexible space robot system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutcliffe, G. D., E-mail: gdsut@mit.edu; Milanese, L. M.; Orozco, D.
2016-11-15
CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint ofmore » the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.« less
Fast Track to Success: Top Young Trainers 2012
ERIC Educational Resources Information Center
Freifeld, Lorri
2012-01-01
Supercharged. High-performers. Leaders of the pack. This article presents "Training" magazine's 2012 Top Young Trainers--those high-potential training professionals who are on the fast track to success. For the fifth year, "Training" magazine is pleased to recognize the outstanding talents, accomplishments, and leadership exhibited by 40 learning…
Boukattaya, Mohamed; Mezghani, Neila; Damak, Tarak
2018-06-01
In this paper, robust and adaptive nonsingular fast terminal sliding-mode (NFTSM) control schemes for the trajectory tracking problem are proposed with known or unknown upper bound of the system uncertainty and external disturbances. The developed controllers take the advantage of the NFTSM theory to ensure fast convergence rate, singularity avoidance, and robustness against uncertainties and external disturbances. First, a robust NFTSM controller is proposed which guarantees that sliding surface and equilibrium point can be reached in a short finite-time from any initial state. Then, in order to cope with the unknown upper bound of the system uncertainty which may be occurring in practical applications, a new adaptive NFTSM algorithm is developed. One feature of the proposed control law is their adaptation techniques where the prior knowledge of parameters uncertainty and disturbances is not needed. However, the adaptive tuning law can estimate the upper bound of these uncertainties using only position and velocity measurements. Moreover, the proposed controller eliminates the chattering effect without losing the robustness property and the precision. Stability analysis is performed using the Lyapunov stability theory, and simulation studies are conducted to verify the effectiveness of the developed control schemes. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.
Affinity-based strategies to fast track development of colon cancer biomarkers — EDRN Public Portal
Our goal is to discover plasma and tissue-based tumor biomarkers that work well enough together to identity colon cancer at early stages, lead to accurate diagnosis and could ultimately allow for individualized treatment.
Regulation of cold-induced sweetening in potatoes and markers for fast-track new variety development
USDA-ARS?s Scientific Manuscript database
Potato breeding is a tedious, time consuming process. With the growing requirements of the potato processing industry for new potato varieties, there is need for effective tools to speed-up new variety development. The purpose of this study was to understand the enzymatic regulation of cold-induce...
2013-01-01
The impact of the Fast Track intervention on externalizing disorders across childhood was examined. Eight hundred-ninety-one early-starting children (69% male; 51% African American) were randomly assigned by matched sets of schools to intervention or control conditions. The 10-year intervention addressed parent behavior-management, child social cognitive skills, reading, home visiting, mentoring, and classroom curricula. Outcomes included psychiatric diagnoses after grades 3, 6, 9, and 12 for conduct disorder, oppositional defiant disorder, attention deficit hyperactivity disorder, and any externalizing disorder. Significant interaction effects between intervention and initial risk level indicated that intervention prevented the lifetime prevalence of all diagnoses, but only among those at highest initial risk, suggesting that targeted intervention can prevent externalizing disorders to promote the raising of healthy children. PMID:21291445
Fast-track for fast times: catching and keeping generation Y in the nursing workforce.
Walker, Kim
2007-04-01
There is little doubt we find ourselves in challenging times as never before has there been such generational diversity in the nursing workforce. Currently, nurses from four distinct (and now well recognised and discussed) generational groups jostle for primacy of recognition and reward. Equally significant is the acute realisation that our ageing profession must find ways to sustain itself in the wake of huge attrition as the 'baby boomer' nurses start retiring over the next ten to fifteen years. These realities impel us to become ever more strategic in our thinking about how best to manage the workforce of the future. This paper presents two exciting and original innovations currently in train at one of Australia's leading Catholic health care providers: firstly, a new fast-track bachelor of nursing program for fee-paying domestic students. This is a collaborative venture between St Vincent's and Mater Health, Sydney (SV&MHS) and the University of Tasmania (UTas); as far as we know, it is unprecedented in Australia. As well, the two private facilities of SV&MHS, St Vincent's Private (SVPH) and the Mater Hospitals, have developed and implemented a unique 'accelerated progression pathway' (APP) to enable registered nurses with talent and ambition to fast track their career through a competency and merit based system of performance management and reward. Both these initiatives are aimed squarely at the gen Y demographic and provide potential to significantly augment our capacity to recruit and retain quality people well into the future.
A fast method for optical simulation of flood maps of light-sharing detector modules
Shi, Han; Du, Dong; Xu, JianFeng; Moses, William W.; Peng, Qiyu
2016-01-01
Optical simulation of the detector module level is highly desired for Position Emission Tomography (PET) system design. Commonly used simulation toolkits such as GATE are not efficient in the optical simulation of detector modules with complicated light-sharing configurations, where a vast amount of photons need to be tracked. We present a fast approach based on a simplified specular reflectance model and a structured light-tracking algorithm to speed up the photon tracking in detector modules constructed with polished finish and specular reflector materials. We simulated conventional block detector designs with different slotted light guide patterns using the new approach and compared the outcomes with those from GATE simulations. While the two approaches generated comparable flood maps, the new approach was more than 200–600 times faster. The new approach has also been validated by constructing a prototype detector and comparing the simulated flood map with the experimental flood map. The experimental flood map has nearly uniformly distributed spots similar to those in the simulated flood map. In conclusion, the new approach provides a fast and reliable simulation tool for assisting in the development of light-sharing-based detector modules with a polished surface finish and using specular reflector materials. PMID:27660376
A fast method for optical simulation of flood maps of light-sharing detector modules
Shi, Han; Du, Dong; Xu, JianFeng; ...
2015-09-03
Optical simulation of the detector module level is highly desired for Position Emission Tomography (PET) system design. Commonly used simulation toolkits such as GATE are not efficient in the optical simulation of detector modules with complicated light-sharing configurations, where a vast amount of photons need to be tracked. Here, we present a fast approach based on a simplified specular reflectance model and a structured light-tracking algorithm to speed up the photon tracking in detector modules constructed with polished finish and specular reflector materials. We also simulated conventional block detector designs with different slotted light guide patterns using the new approachmore » and compared the outcomes with those from GATE simulations. And while the two approaches generated comparable flood maps, the new approach was more than 200–600 times faster. The new approach has also been validated by constructing a prototype detector and comparing the simulated flood map with the experimental flood map. The experimental flood map has nearly uniformly distributed spots similar to those in the simulated flood map. In conclusion, the new approach provides a fast and reliable simulation tool for assisting in the development of light-sharing-based detector modules with a polished surface finish and using specular reflector materials.« less
A new fast scanning system for the measurement of large angle tracks in nuclear emulsions
NASA Astrophysics Data System (ADS)
Alexandrov, A.; Buonaura, A.; Consiglio, L.; D'Ambrosio, N.; De Lellis, G.; Di Crescenzo, A.; Di Marco, N.; Galati, G.; Lauria, A.; Montesi, M. C.; Pupilli, F.; Shchedrina, T.; Tioukov, V.; Vladymyrov, M.
2015-11-01
Nuclear emulsions have been widely used in particle physics to identify new particles through the observation of their decays thanks to their unique spatial resolution. Nevertheless, before the advent of automatic scanning systems, the emulsion analysis was very demanding in terms of well trained manpower. Due to this reason, they were gradually replaced by electronic detectors, until the '90s, when automatic microscopes started to be developed in Japan and in Europe. Automatic scanning was essential to conceive large scale emulsion-based neutrino experiments like CHORUS, DONUT and OPERA. Standard scanning systems have been initially designed to recognize tracks within a limited angular acceptance (θ lesssim 30°) where θ is the track angle with respect to a line perpendicular to the emulsion plane. In this paper we describe the implementation of a novel fast automatic scanning system aimed at extending the track recognition to the full angular range and improving the present scanning speed. Indeed, nuclear emulsions do not have any intrinsic limit to detect particle direction. Such improvement opens new perspectives to use nuclear emulsions in several fields in addition to large scale neutrino experiments, like muon radiography, medical applications and dark matter directional detection.
2000-01-01
Fast Track is a multisite, multicomponent preventive intervention for young children at high risk for long-term antisocial behavior. Based on a comprehensive developmental model, this intervention includes a universal-level classroom program plus social-skill training, academic tutoring, parent training, and home visiting to improve competencies and reduce problems in a high-risk group of children selected in kindergarten. The theoretical principles and clinical strategies utilized in the Fast Track Project are described to illustrate the interplay between basic developmental research, the understanding of risk and protective factors, and a research-based model of preventive intervention that integrates universal and indicated models of prevention.
Airborne optical tracking control system design study
NASA Astrophysics Data System (ADS)
1992-09-01
The Kestrel LOS Tracking Program involves the development of a computer and algorithms for use in passive tracking of airborne targets from a high altitude balloon platform. The computer receivers track error signals from a video tracker connected to one of the imaging sensors. In addition, an on-board IRU (gyro), accelerometers, a magnetometer, and a two-axis inclinometer provide inputs which are used for initial acquisitions and course and fine tracking. Signals received by the control processor from the video tracker, IRU, accelerometers, magnetometer, and inclinometer are utilized by the control processor to generate drive signals for the payload azimuth drive, the Gimballed Mirror System (GMS), and the Fast Steering Mirror (FSM). The hardware which will be procured under the LOS tracking activity is the Controls Processor (CP), the IRU, and the FSM. The performance specifications for the GMS and the payload canister azimuth driver are established by the LOS tracking design team in an effort to achieve a tracking jitter of less than 3 micro-rad, 1 sigma for one axis.
"Joined up" Thinking? Unsupported "Fast-Track" Transitions in the Context of Parental Substance Use
ERIC Educational Resources Information Center
Wilson, Sarah; Cunningham-Burley, Sarah; Bancroft, Angus; Backett-Milburn, Kathryn
2008-01-01
Recent policy responses to the risks entailed in "fast-track" school-work transitions have targeted careleavers and young people identified as "not in education, employment or training" (NEET). However, this approach has been criticised as diverting attention away from the fragile circumstances of others who may receive little…
ERIC Educational Resources Information Center
Bierman, Karen L.; Coie, John D.; Dodge, Kenneth A.; Greenberg, Mark T.; Lochman, John E.; McMahon, Robert J.; Pinderhughes, Ellen
2010-01-01
Objective: This article examines the impact of a universal social-emotional learning program, the Fast Track PATHS (Promoting Alternative Thinking Strategies) curriculum and teacher consultation, embedded within the Fast Track selective prevention model. Method: The longitudinal analysis involved 2,937 children of multiple ethnicities who remained…
Fast track pathway for perforated appendicitis.
Frazee, Richard; Abernathy, Stephen; Davis, Matthew; Isbell, Travis; Regner, Justin; Smith, Randall
2017-04-01
Perforated appendicitis is associated with an increased morbidity and length of stay. "Fast track" protocols have demonstrated success in shortening hospitalization without increasing morbidity for a variety of surgical processes. This study evaluates a fast track pathway for perforated appendicitis. In 2013, a treatment pathway for perforated appendicitis was adopted by the Acute Care Surgery Service for patients having surgical management of perforated appendicitis. Interval appendectomy was excluded. Patients were treated initially with intravenous antibiotics and transitioned to oral antibiotics and dismissed when medically stable and tolerating oral intake. A retrospective review of patients managed on the fast track pathway was undertaken to analyze length of stay, morbidity, and readmissions. Thirty-four males and twenty-one females with an average age of 46.8 years underwent laparoscopic appendectomy for perforated appendicitis between January 2013 and December 2014. Pre-existing comorbidities included hypertension 42%, diabetes mellitus 11%, COPD 5% and heart disease 2%. No patient had conversion to open appendectomy. Average length of stay was 2.67 days and ranged from 1 to 12 days (median 2 days). Postoperative morbidity was 20% and included abscess (6 patients), prolonged ileus (3 patients), pneumonia (1 patient), and congestive heart failure (1 patient). Five patients were readmitted for abscess (3 patients), congestive heart failure (1 patient), and pneumonia (1 patient). A fast track pathway for perforated appendicitis produced shorter length of stay and acceptable postoperative morbidity and readmission. This offers the potential for significant cost savings over current national practice patterns. Copyright © 2016 Elsevier Inc. All rights reserved.
Finite-time control for nonlinear spacecraft attitude based on terminal sliding mode technique.
Song, Zhankui; Li, Hongxing; Sun, Kaibiao
2014-01-01
In this paper, a fast terminal sliding mode control (FTSMC) scheme with double closed loops is proposed for the spacecraft attitude control. The FTSMC laws are included both in an inner control loop and an outer control loop. Firstly, a fast terminal sliding surface (FTSS) is constructed, which can drive the inner loop tracking-error and the outer loop tracking-error on the FTSS to converge to zero in finite time. Secondly, FTSMC strategy is designed by using Lyaponov's method for ensuring the occurrence of the sliding motion in finite time, which can hold the character of fast transient response and improve the tracking accuracy. It is proved that FTSMC can guarantee the convergence of tracking-error in both approaching and sliding mode surface. Finally, simulation results demonstrate the effectiveness of the proposed control scheme. © 2013 ISA. Published by Elsevier Ltd. All rights reserved.
Cheong, Fook Chiong; Wong, Chui Ching; Gao, YunFeng; Nai, Mui Hoon; Cui, Yidan; Park, Sungsu; Kenney, Linda J.; Lim, Chwee Teck
2015-01-01
Tracking fast-swimming bacteria in three dimensions can be extremely challenging with current optical techniques and a microscopic approach that can rapidly acquire volumetric information is required. Here, we introduce phase-contrast holographic video microscopy as a solution for the simultaneous tracking of multiple fast moving cells in three dimensions. This technique uses interference patterns formed between the scattered and the incident field to infer the three-dimensional (3D) position and size of bacteria. Using this optical approach, motility dynamics of multiple bacteria in three dimensions, such as speed and turn angles, can be obtained within minutes. We demonstrated the feasibility of this method by effectively tracking multiple bacteria species, including Escherichia coli, Agrobacterium tumefaciens, and Pseudomonas aeruginosa. In addition, we combined our fast 3D imaging technique with a microfluidic device to present an example of a drug/chemical assay to study effects on bacterial motility. PMID:25762336
Computational tools and lattice design for the PEP-II B-Factory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai, Y.; Irwin, J.; Nosochkov, Y.
1997-02-01
Several accelerator codes were used to design the PEP-II lattices, ranging from matrix-based codes, such as MAD and DIMAD, to symplectic-integrator codes, such as TRACY and DESPOT. In addition to element-by-element tracking, we constructed maps to determine aberration strengths. Furthermore, we have developed a fast and reliable method (nPB tracking) to track particles with a one-turn map. This new technique allows us to evaluate performance of the lattices on the entire tune-plane. Recently, we designed and implemented an object-oriented code in C++ called LEGO which integrates and expands upon TRACY and DESPOT. {copyright} {ital 1997 American Institute of Physics.}
Computational tools and lattice design for the PEP-II B-Factory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai Yunhai; Irwin, John; Nosochkov, Yuri
1997-02-01
Several accelerator codes were used to design the PEP-II lattices, ranging from matrix-based codes, such as MAD and DIMAD, to symplectic-integrator codes, such as TRACY and DESPOT. In addition to element-by-element tracking, we constructed maps to determine aberration strengths. Furthermore, we have developed a fast and reliable method (nPB tracking) to track particles with a one-turn map. This new technique allows us to evaluate performance of the lattices on the entire tune-plane. Recently, we designed and implemented an object-oriented code in C++ called LEGO which integrates and expands upon TRACY and DESPOT.
Wanden-Berghe, Carmina; Sanz-Valero, Javier; Arroyo-Sebastián, Antonio; Cheikh-Moussa, Kamila; Moya-Forcen, Pedro
2016-07-19
Introducción: Preoperative nutritional status (NS) has consequences on postoperative (POSTOP) recovery. Our aim was to systematically review the nutritional interventions (NI) in Fast-Track protocols for colorectal cancer surgery and assess morbidity-mortality and patient´s recovery. Systematic review of scientific literature after consulting bibliographic databases: Medline, The Cochrane Library, Scopus, Embase, Web of Science, Institute for Scientific Information, Latin American and Caribbean Health Sciences Literature, The Cumulative Index to Nursing and Allied Health Literature. MeSH Descriptors: "Colorectal Surgery", "Fast-Track", "Perioperative Care", "Nutrition Therapy" and "Enhanced recovery programme". Filters: "Humans", Adult (19+ years) and "Clinical Trial". Variables POSTOP outcomes: bowel recovery (BR), hospital stay (HS), complications and death. Selected studies, 27, had good or excellent methodological quality. From 25 to 597 patients were included. Aged between 16-94 years, men were predominant in 66.6%. NS was evaluated in 13 studies; 7 by Body Mass Index while one by Subjective Global Assessment. One presented POSTOP data. Fast-Track groups had solids, liquids or supplements (SS) in prior 2-8 hours. SS were high in carbohydrates, immune-nutrients and non-residue. Free liquids, solids and SS intake was allowed in POSTOP. Half traditional groups fasted between 3-12 hours and resumed POSTOP food intake progressively. Fast-Track groups had early BR (p < 0.01). Traditional groups had more infections episodes, deaths and a longer HS. Great variability between NI but had a common item; early intake. Although was seen patient's recovery. Future studies with detailed NI characteristics are need. Nutritional status must be assessed for a higher acknowledgement of NI impact.
Industrial applications of ion track technology
NASA Astrophysics Data System (ADS)
Hanot, H.; Ferain, E.
2009-03-01
It4ip sa is a spin out from the Université Catholique de Louvain (Belgium) dedicated to the development and production of unique templates and membranes based on the combination of ion track technology of polymers. It supplies customers with hi-tech products, state-of-the-art research and product development services with template capability to make high value added membranes. Notably based on results coming from several collaborative R&D projects supported by European and Regional funding, recent improvements of ion track technology open new doors for fast growing applications in niche markets. This paper reviews some of these Hi-Tec applications in different fields such as in healthcare (oncology, drug control release combined to implant and artificial organs etc.), energy (fuel cells and batteries etc.), water de-contamination and electronics (OLED etc.).
Fast steering mirror for laser communication
NASA Astrophysics Data System (ADS)
Langenbach, Harald; Schmid, Manfred
2005-07-01
Future multimedia satellites require communication at large bandwidth which can be achieved by means of optical communication links. TESAT Spacecom is currently developing a Laser Communication Terminal (LCT) for such applications under DLR contract. EADS Astrium is developing and building the mechanisms for Pointing, Acquisition and Tracking (PAT) of the laser beam between two Laser Communication Terminals. Based on this development work the development of mechanism H/W to be flown on TerraSar X is currently under way. After a short description of the general arrangement of the Mechanisms inside the LCT, the paper describes the design of the fast steering mirrors (FSM) reflecting the critical requirements and the solutions how to achieve them.
Description and performance of track and primary-vertex reconstruction with the CMS tracker
Chatrchyan, Serguei
2014-10-16
A description is provided of the software algorithms developed for the CMS tracker both for reconstructing charged-particle trajectories in proton-proton interactions and for using the resulting tracks to estimate the positions of the LHC luminous region and individual primary-interaction vertices. Despite the very hostile environment at the LHC, the performance obtained with these algorithms is found to be excellent. For tbar t events under typical 2011 pileup conditions, the average track-reconstruction efficiency for promptly-produced charged particles with transverse momenta of p T > 0.9GeV is 94% for pseudorapidities of |η| < 0.9 and 85% for 0.9 < |η| < 2.5.more » The inefficiency is caused mainly by hadrons that undergo nuclear interactions in the tracker material. For isolated muons, the corresponding efficiencies are essentially 100%. For isolated muons of p T = 100GeV emitted at |η| < 1.4, the resolutions are approximately 2.8% in p T, and respectively, 10μm and 30μm in the transverse and longitudinal impact parameters. The position resolution achieved for reconstructed primary vertices that correspond to interesting pp collisions is 10–12μm in each of the three spatial dimensions. The tracking and vertexing software is fast and flexible, and easily adaptable to other functions, such as fast tracking for the trigger, or dedicated tracking for electrons that takes into account bremsstrahlung.« less
Evaluation of a Chlamydia trachomatis-specific, commercial, real-time PCR for use with ocular swabs.
Pickering, Harry; Holland, Martin J; Last, Anna R; Burton, Matthew J; Burr, Sarah E
2018-02-20
Trachoma, the leading infectious cause of blindness worldwide, is caused by conjunctival Chlamydia trachomatis infection. Trachoma is diagnosed clinically by observation of conjunctival inflammation and/or scarring; however, there is evidence that monitoring C. trachomatis infection may be required for elimination programmes. There are many commercial and 'in-house' nucleic acid amplification tests for the detection of C. trachomatis DNA, but the majority have not been validated for use with ocular swabs. This study evaluated a commercial assay, the Fast-Track Vaginal swab kit, using conjunctival samples from trachoma-endemic areas. An objective, biostatistical-based method for binary classification of continuous PCR data was developed, to limit potential user-bias in diagnostic settings. The Fast-Track Vaginal swab assay was run on 210 ocular swab samples from Guinea-Bissau and Tanzania. Fit of individual amplification curves to exponential or sigmoid models, derivative and second derivative of the curves and final fluorescence value were examined for utility in thresholding for determining positivity. The results from the Fast-Track Vaginal swab assay were evaluated against a commercial test (Amplicor CT/NG) and a non-commercial test (in-house droplet digital PCR), both of whose performance has previously been evaluated. Significant evidence of exponential amplification (R 2 > 0.99) and final fluorescence > 0.15 were combined for thresholding. This objective approach identified a population of positive samples, however there were a subset of samples that amplified towards the end of the cycling protocol (at or later than 35 cycles), which were less clearly defined. The Fast-Track Vaginal swab assay showed good sensitivity against the commercial (95.71) and non-commercial (97.18) tests. Specificity was lower against both (90.00 and 96.55, respectively). This study defined a simple, automated protocol for binary classification of continuous, real-time qPCR data, for use in an end-point diagnostic test. This method identified a population of positive samples, however, as with manual thresholding, a subset of samples that amplified towards the end of the cycling program were less easily classified. When used with ocular swabs, the Fast-Track Vaginal swab assay had good sensitivity for C. trachomatis detection, but lower specificity than the commercial and non-commercial assays it was evaluated against, possibly leading to false positives.
ERIC Educational Resources Information Center
Journal of the American Academy of Child & Adolescent Psychiatry, 2007
2007-01-01
Objective: This study tests the efficacy of the Fast Track Program in preventing antisocial behavior and psychiatric disorders among groups varying in initial risk. Method: Schools within four sites (Durham, NC; Nashville, TN; Seattle, WA; and rural central Pennsylvania) were selected as high-risk institutions based on neighborhood crime and…
Fast Tracking School Site Acquisition: A Perspective of an Eminent Domain Attorney.
ERIC Educational Resources Information Center
Behrens, Jerry
This paper discusses key issues in fast-tracking the acquisition of school sites in California. Discussion addresses: (1) assembling an experienced team; (2) whether the property owner is a willing or unwilling seller; (3) level of community support or opposition to the site; (4) timing and commencement of California Environmental Quality Act…
Electrically tunable lens speeds up 3D orbital tracking
Annibale, Paolo; Dvornikov, Alexander; Gratton, Enrico
2015-01-01
3D orbital particle tracking is a versatile and effective microscopy technique that allows following fast moving fluorescent objects within living cells and reconstructing complex 3D shapes using laser scanning microscopes. We demonstrated notable improvements in the range, speed and accuracy of 3D orbital particle tracking by replacing commonly used piezoelectric stages with Electrically Tunable Lens (ETL) that eliminates mechanical movement of objective lenses. This allowed tracking and reconstructing shape of structures extending 500 microns in the axial direction. Using the ETL, we tracked at high speed fluorescently labeled genomic loci within the nucleus of living cells with unprecedented temporal resolution of 8ms using a 1.42NA oil-immersion objective. The presented technology is cost effective and allows easy upgrade of scanning microscopes for fast 3D orbital tracking. PMID:26114037
Large Area Field of View for Fast Temporal Resolution Astronomy
NASA Astrophysics Data System (ADS)
Covarrubias, Ricardo A.
2018-01-01
Scientific CMOS (sCMOS) technology is especially relevant for high temporal resolution astronomy combining high resolution, large field of view with very fast frame rates, without sacrificing ultra-low noise performance. Solar Astronomy, Near Earth Object detections, Space Debris Tracking, Transient Observations or Wavefront Sensing are among the many applications this technology can be utilized. Andor Technology is currently developing the next-generation, very large area sCMOS camera with an extremely low noise, rapid frame rates, high resolution and wide dynamic range.
Fast-track surgery concepts for congenital urogenital anomalies.
Bizic, Marta R; Majstorovic, Marko J; Vukadinovic, Vojkan; Korac, Gradimir; Krstic, Zoran; Radojicic, Zoran; Ducic, Sinisa; Djordjevic, Miroslav L
2013-01-01
To investigate the possibility of fast-track surgery concepts in pediatric urology department as a single center study model of a developing country. The study included 1620 patients surgically treated at the pediatric urology department, from 2009 to 2011. According to the congenital anomalies, all patients were classified in one of four groups: I - testicular anomalies (197 patients); II - external genital anomalies (453); III - upper urinary tract anomalies (801) and IV - associated anomalies (169). We analyzed the total duration of stay in the hospital of all patients among all treating doctors concerning the anomaly. Statistically significant difference in total length of hospitalization of all patients in Group I was noted in Doctors 1 and 5 (F=10.36** for F0.05;5;12=3.11 and F0.01;5;12=5.06), as well as in the Group II (F=17.01** for F0.05;5;12=3.11 and F0.01;5;12=5.06). Statistical analysis was not possible to be performed in groups III and IV because of lack of the patients. Analyzing the length of hospitalization of the patients treated at the urology department, all doctors showed the tendency to shorten the total length of hospitalization in patients of all groups. Majority of the studies carried out on pediatric urology departments in developed countries, showed that over 50% of children were successfully treated using fast-track surgery concept. Modern methods of surgical management and anesthesia allow decrease of hospitalization length, financial savings to the healthcare system and better comfort for patients.
NASA Astrophysics Data System (ADS)
Liu, Hongfei; Pan, Gaofeng; Lin, Zhong; Liu, Cheng; Zhu, Wenbai; Nan, Rendong; Li, Chunsheng; Gao, Guanjun; Luo, Wenyong; Jin, Chengjin; Song, Jinyou
2017-11-01
The construction of FAST telescope was completed in Guizhou province of China in September 2016, and a kind of novel high-stability 48-core bendable and movable optical cable was developed and applied in analog data optical transmission system of FAST. Novel structure and selective material of this optical cable ensure high stability of optical power in the process of cables round-trip motion when telescope is tracking a radio source. The 105 times bend and stretch accelerated experiment for this optical cable was implemented, and real-time optical and RF signal power fluctuation were measured. The physical structure of optical cables after 105 times round-trip motion is in good condition; the real-time optical power attenuation fluctuation is smaller than 0.044 dB; the real-time RF power fluctuation is smaller than 0.12 dB. The optical cable developed in this letter meets the requirement of FAST and has been applied in FAST telescope.
High-Speed Automatic Microscopy for Real Time Tracks Reconstruction in Nuclear Emulsion
NASA Astrophysics Data System (ADS)
D'Ambrosio, N.
2006-06-01
The Oscillation Project with Emulsion-tRacking Apparatus (OPERA) experiment will use a massive nuclear emulsion detector to search for /spl nu//sub /spl mu///spl rarr//spl nu//sub /spl tau// oscillation by identifying /spl tau/ leptons through the direct detection of their decay topology. The feasibility of experiments using a large mass emulsion detector is linked to the impressive progress under way in the development of automatic emulsion analysis. A new generation of scanning systems requires the development of fast automatic microscopes for emulsion scanning and image analysis to reconstruct tracks of elementary particles. The paper presents the European Scanning System (ESS) developed in the framework of OPERA collaboration.
ERIC Educational Resources Information Center
Ineson, Sue; Seeling, Stephen S.
2005-01-01
A Working Group on Medical Passports was established in 2002 by the International Association of Medical Regulatory Authorities. The goal of this group was to develop a fast-track registration process for highly qualified medical practitioners wishing to move from one jurisdiction to another. A "medical passport" would be available only to…
Advance Approach to Concept and Design Studies for Space Missions
NASA Technical Reports Server (NTRS)
Deutsch, M.; Nichols, J.
1999-01-01
Recent automated and advanced techniques developed at JPL have created a streamlined and fast-track approach to initial mission conceptualization and system architecture design, answering the need for rapid turnaround of trade studies for potential proposers, as well as mission and instrument study groups.
NASA Astrophysics Data System (ADS)
Williamson, Andrew; Arnold, Neil; Banwell, Alison; Willis, Ian
2017-04-01
Supraglacial lakes (SGLs) on the Greenland Ice Sheet (GrIS) influence ice dynamics if draining rapidly by hydrofracture, which can occur in under 24 hours. MODerate-resolution Imaging Spectroradiometer (MODIS) data are often used to investigate SGLs, including calculating SGL area changes through time, but no existing work presents a method that tracks changes in individual (and total) SGL volume in MODIS imagery over a melt season. Here, we present such a method. First, we tested three automated approaches to derive SGL areas from MODIS imagery by comparing calculated areas for the Paakitsoq and Store Glacier regions in West Greenland with areas derived from Landsat-8 (LS8) images. Second, we applied a physically-based depth-calculation algorithm to the pixels within the SGL boundaries from the best performing method, and validated the resultant depths with those calculated using the same method applied to LS8 imagery. Our results indicated that SGL areas are most accurately generated using dynamic thresholding of MODIS band 1 (red) with a 0.640 threshold value. Calculated SGL area, depth and volume values from MODIS were closely comparable to those derived from LS8. The best performing area- and depth-detection methods were then incorporated into a Fully Automated SGL Tracking ("FAST") algorithm that tracks individual SGLs between successive MODIS images. It identified 43 (Paakitsoq) and 19 (Store Glacier) rapidly draining SGLs during 2014, representing 21% and 15% of the respective total SGL populations, including some clusters of rapidly draining SGLs. We found no relationship between the water volumes contained within these rapidly draining SGLs and the ice thicknesses beneath them, indicating that a critical water volume linearly related to ice thickness cannot explain the incidence of rapid drainage. The FAST algorithm, which we believe to be the most comprehensive SGL tracking algorithm developed to date, has the potential to investigate statistical relationships between SGL areas, volumes and drainage events over wide areas of the GrIS, and over multiple seasons. It could also allow further insights into factors that may trigger rapid SGL drainage.
Berthelsen, Connie Bøttcher; Lindhardt, Tove; Frederiksen, Kirsten
2014-12-01
To generate a substantive grounded theory of relatives' pattern of behaviour in older patients' fast-track treatment programmes during total hip or knee replacement. Fast-track treatment programmes are designed to make total hip and knee replacements more efficient through recovery improvements. The support of relatives during older patients' trajectory is important. However, knowledge is needed on the relatives' pattern of behaviour to strengthen their involvement in fast-track treatment programmes. We used a Glaserian grounded theory approach based on a systematic generation of theory from data to explain the latent pattern of behaviour of relatives. Data were collected from 2010-2011 in orthopaedic wards at two Danish university hospitals and consisted of 14 non-participant observations, 14 postobservational interviews and five interviews. Seven relatives of patients over 70 years of age participated. The constant comparative method was the guiding principle for simultaneous data collection, data analysis and coding, while theoretically sampling and writing memos. Maintaining Unity emerged as the relatives' pattern of behaviour through which they resolved their main concern: preventing the patients from feeling alone. The relatives resolved their main concern through three interchangeable behavioural modes: Protecting Mode, by providing loving and respectful support; Substituting Mode, with practical and cognitive support; and an Adapting Mode, by trying to fit in with the patients' and health professionals' requirements. The substantive theory of Maintaining Unity offers knowledge of relatives' strong desire to provide compassionate and loving support for the older patients during fast-track treatment programmes. © 2014 John Wiley & Sons Ltd.
Fast left ventricle tracking in CMR images using localized anatomical affine optical flow
NASA Astrophysics Data System (ADS)
Queirós, Sandro; Vilaça, João. L.; Morais, Pedro; Fonseca, Jaime C.; D'hooge, Jan; Barbosa, Daniel
2015-03-01
In daily cardiology practice, assessment of left ventricular (LV) global function using non-invasive imaging remains central for the diagnosis and follow-up of patients with cardiovascular diseases. Despite the different methodologies currently accessible for LV segmentation in cardiac magnetic resonance (CMR) images, a fast and complete LV delineation is still limitedly available for routine use. In this study, a localized anatomically constrained affine optical flow method is proposed for fast and automatic LV tracking throughout the full cardiac cycle in short-axis CMR images. Starting from an automatically delineated LV in the end-diastolic frame, the endocardial and epicardial boundaries are propagated by estimating the motion between adjacent cardiac phases using optical flow. In order to reduce the computational burden, the motion is only estimated in an anatomical region of interest around the tracked boundaries and subsequently integrated into a local affine motion model. Such localized estimation enables to capture complex motion patterns, while still being spatially consistent. The method was validated on 45 CMR datasets taken from the 2009 MICCAI LV segmentation challenge. The proposed approach proved to be robust and efficient, with an average distance error of 2.1 mm and a correlation with reference ejection fraction of 0.98 (1.9 +/- 4.5%). Moreover, it showed to be fast, taking 5 seconds for the tracking of a full 4D dataset (30 ms per image). Overall, a novel fast, robust and accurate LV tracking methodology was proposed, enabling accurate assessment of relevant global function cardiac indices, such as volumes and ejection fraction
Fast-track cardiac care for adult cardiac surgical patients.
Zhu, Fang; Lee, Anna; Chee, Yee Eot
2012-10-17
Fast-track cardiac care is a complex intervention involving several components of care during cardiac anaesthesia and in the postoperative period, all with the ultimate aim of early extubation after surgery, to reduce the length of stay in the intensive care unit and in the hospital. Safe and effective fast-track cardiac care may reduce hospital costs. This is an update of a Cochrane review published in 2003. To update the evidence on the safety and effectiveness of fast-track cardiac care compared to conventional (not fast-track) care in adult patients undergoing cardiac surgery. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (2012, Issue 3), MEDLINE (January 1966 to April 2012), EMBASE (January 1980 to April 2012), CINAHL (January 1982 to April 2012), and ISI Web of Science (January 2003 to April 2012). We searched reference lists of articles and contacted experts in the field. All randomized controlled trials of adult cardiac surgical patients (coronary artery bypass grafts, aortic valve replacement, mitral valve replacement) that compared fast-track cardiac care and conventional (not fast-track) care groups were included. We focused on the following fast-track interventions that were designed for early extubation after surgery, administration of low-dose opioid based general anaesthesia during cardiac surgery and the use of a time-directed extubation protocol after surgery. The primary outcome was the risk of mortality. Secondary outcomes included postoperative complications, reintubation within 24 hours of surgery, time to extubation, length of stay in the intensive care unit and in the hospital, quality of life after surgery and hospital costs. Two review authors independently assessed trial quality and extracted the data. Study authors were contacted for additional information. We used a random-effects model and reported relative risk (RR), mean difference (MD) and 95% confidence intervals (95% CI). Twenty-five trials involving 4118 patients were included in the review. There were two studies with a low risk of bias and nine studies with a high risk of bias. There were no differences in the risk of mortality within the first year after surgery between low-dose versus high-dose opioid based general anaesthesia groups (RR 0.58, 95% CI 0.28 to 1.18) and between early extubation protocol versus usual care groups (RR 0.84, 95% CI 0.40 to 1.75).There were no significant differences between low-dose versus high-dose opioid based anaesthesia groups for postoperative complications: myocardial infarction (RR 0.98, 95% CI 0.48 to 1.99), reintubation (RR 1.77, 95% CI 0.38 to 8.27), acute renal failure (RR 1.19, 95% CI 0.33 to 4.33), major bleeding (RR 0.48, 95% CI 0.16 to 1.44), and stroke (RR 1.17, 95% CI 0.36 to 3.78). Compared to the usual care, there were no significant differences in the risk of postoperative complications associated with early extubation: myocardial infarction (RR 0.94, 95% CI 0.55 to 1.60), reintubation (RR 1.91, 95% CI 0.90 to 4.07), acute renal failure (RR 0.77, 95% CI 0.19 to 3.10), major bleeding (RR 0.80, 95% CI 0.45 to 1.44), stroke (RR 0.87, 95% CI 0.31 to 2.46), major sepsis (RR 1.25, 95% CI 0.08 to 19.75) and wound infection (RR 0.67, 95% CI 0.25 to 1.83).Although there were high levels of heterogeneity, both low-dose opioid anaesthesia and the use of time-directed extubation protocols were associated with reductions in the time to extubation (3.0 to 10.5 hours) and in the length of stay in the intensive care unit (0.4 to 8.7 hours). However, these fast-track care interventions were not associated with reductions in the total length of stay in hospital. One high quality cost-effectiveness analysis included in a randomized controlled trial showed that early extubation was likely to be cost-effective. The use of low-dose opioid based general anaesthesia and time-directed protocols for fast-track interventions have similar risks of mortality and major postoperative complications to conventional (not fast-track) care, and therefore appear to be safe in patients considered to be at low to moderate risk. These fast-track interventions reduced the time to extubation and shortened the length of stay in the intensive care unit, but did not reduce the length of stay in the hospital.
The performance of the MROI fast tip-tilt correction system
NASA Astrophysics Data System (ADS)
Young, John; Buscher, David; Fisher, Martin; Haniff, Christopher; Rea, Alexander; Seneta, Eugene; Sun, Xiaowei; Wilson, Donald; Farris, Allen; Olivares, Andres
2014-07-01
The fast tip-tilt (FTT) correction system for the Magdalena Ridge Observatory Interferometer (MROI) is being developed by the University of Cambridge. The design incorporates an EMCCD camera protected by a thermal enclosure, optical mounts with passive thermal compensation, and control software running under Xenomai real-time Linux. The complete FTT system is now undergoing laboratory testing prior to being installed on the first MROI unit telescope in the fall of 2014. We are following a twin-track approach to testing the closed-loop performance: tracking tip-tilt perturbations introduced by an actuated flat mirror in the laboratory, and undertaking end-to-end simulations that incorporate realistic higher-order atmospheric perturbations. We report test results that demonstrate (a) the high stability of the entire opto-mechanical system, realized with a completely passive design; and (b) the fast tip-tilt correction performance and limiting sensitivity. Our preliminary results in both areas are close to those needed to realise the ambitious stability and sensitivity goals of the MROI which aims to match the performance of current natural guide star adaptive optics systems.
Quintana-Díaz, Manuel; Fabra-Cadenas, Sara; Gómez-Ramírez, Susana; Martínez-Virto, Ana; García-Erce, José A; Muñoz, Manuel
2016-03-01
Clinically significant anaemia, requiring red blood cell transfusions, is frequently observed in Emergency Departments (ED). To optimise blood product use, we developed a clinical protocol for the management of iron-deficiency anaemia in a fast-track anaemia clinic within the ED. From November 2010 to January 2014, patients presenting with sub-acute, moderate-to-severe anaemia (haemoglobin [Hb] <11 g/dL) and confirmed or suspected iron deficiency were referred to the fast-track anaemia clinic. Those with absolute or functional iron deficiency were given intravenous (IV) ferric carboxymaltose 500-1,000 mg/week and were reassessed 4 weeks after receiving the total iron dose. The primary study outcome was the haematological response (Hb≥12 g/dL and/or Hb increment ≥2 g/dL). Changes in blood and iron parameters, transfusion rates and IV iron-related adverse drug effects were secondary outcomes. Two hundred and two anaemic patients with iron deficiency (150 women/52 men; mean age, 64 years) were managed in the fast-track anaemia clinic, and received a median IV iron dose of 1,500 mg (1,000-2,000 mg). Gastro-intestinal (44%) or gynaecological (26%) bleeding was the most frequent cause of the anaemia. At follow-up (183 patients), the mean Hb increment was 3.9±2.2 g/dL; 84% of patients were classified as responders and blood and iron parameters normalised in 90%. During follow-up, 35 (17%) patients needed transfusions (2 [range: 1-3] units per patient) because they had low Hb levels, symptoms of anaemia and/or were at risk. Eight mild and one moderate, self-limited adverse drug effects were witnessed. Our data support the feasibility of a clinical protocol for management of sub-acute anaemia with IV iron in the ED. IV iron was efficacious, safe and well tolerated. Early management of anaemia will improve the use of blood products in the ED.
Fast Markerless Tracking for Augmented Reality in Planar Environment
NASA Astrophysics Data System (ADS)
Basori, Ahmad Hoirul; Afif, Fadhil Noer; Almazyad, Abdulaziz S.; AbuJabal, Hamza Ali S.; Rehman, Amjad; Alkawaz, Mohammed Hazim
2015-12-01
Markerless tracking for augmented reality should not only be accurate but also fast enough to provide a seamless synchronization between real and virtual beings. Current reported methods showed that a vision-based tracking is accurate but requires high computational power. This paper proposes a real-time hybrid-based method for tracking unknown environments in markerless augmented reality. The proposed method provides collaboration of vision-based approach with accelerometers and gyroscopes sensors as camera pose predictor. To align the augmentation relative to camera motion, the tracking method is done by substituting feature-based camera estimation with combination of inertial sensors with complementary filter to provide more dynamic response. The proposed method managed to track unknown environment with faster processing time compared to available feature-based approaches. Moreover, the proposed method can sustain its estimation in a situation where feature-based tracking loses its track. The collaboration of sensor tracking managed to perform the task for about 22.97 FPS, up to five times faster than feature-based tracking method used as comparison. Therefore, the proposed method can be used to track unknown environments without depending on amount of features on scene, while requiring lower computational cost.
Rakhimberdiev, Eldar; Winkler, David W; Bridge, Eli; Seavy, Nathaniel E; Sheldon, Daniel; Piersma, Theunis; Saveliev, Anatoly
2015-01-01
Solar archival tags (henceforth called geolocators) are tracking devices deployed on animals to reconstruct their long-distance movements on the basis of locations inferred post hoc with reference to the geographical and seasonal variations in the timing and speeds of sunrise and sunset. The increased use of geolocators has created a need for analytical tools to produce accurate and objective estimates of migration routes that are explicit in their uncertainty about the position estimates. We developed a hidden Markov chain model for the analysis of geolocator data. This model estimates tracks for animals with complex migratory behaviour by combining: (1) a shading-insensitive, template-fit physical model, (2) an uncorrelated random walk movement model that includes migratory and sedentary behavioural states, and (3) spatially explicit behavioural masks. The model is implemented in a specially developed open source R package FLightR. We used the particle filter (PF) algorithm to provide relatively fast model posterior computation. We illustrate our modelling approach with analysis of simulated data for stationary tags and of real tracks of both a tree swallow Tachycineta bicolor migrating along the east and a golden-crowned sparrow Zonotrichia atricapilla migrating along the west coast of North America. We provide a model that increases accuracy in analyses of noisy data and movements of animals with complicated migration behaviour. It provides posterior distributions for the positions of animals, their behavioural states (e.g., migrating or sedentary), and distance and direction of movement. Our approach allows biologists to estimate locations of animals with complex migratory behaviour based on raw light data. This model advances the current methods for estimating migration tracks from solar geolocation, and will benefit a fast-growing number of tracking studies with this technology.
The "Push-Pull" Approach to Fast-Track Management Development: A Case Study in Scientific Publishing
ERIC Educational Resources Information Center
Fojt, Martin; Parkinson, Stephen; Peters, John; Sandelands, Eric
2008-01-01
Purpose: The purpose of this paper is to explore how a medium sized business has addressed what it has termed a "push-pull" method of management and organization development, based around an action learning approach. Design/methodology/approach: The paper sets out a methodology that other SMEs might look to replicate in their management and…
Future Leaders: The Way Forward?
ERIC Educational Resources Information Center
Earley, Peter; Weindling, Dick; Bubb, Sara; Glenn, Meli
2009-01-01
The recruitment and retention of senior school leaders is high on the UK Government's agenda with much attention currently being given to succession planning. Future Leaders and other fast track leadership development programmes are, in part, a response to this "crisis" brought about by demographic change--many headteachers are due to…
NASA Technical Reports Server (NTRS)
Hunter, Stanley; deNolfo, G. A.; Barbier, L. M.; Link, J. T.; Son, S.; Floyd, S. R.; Guardala, N.; Skopec, M.; Stark, B.
2008-01-01
The Neutron Imaging Camera (NIC) is based on the Three-dimensional Track Imager (3DTI) technology developed at GSFC for gamma-ray astrophysics applications. The 3-DTI, a large volume time-projection chamber, provides accurate, approximately 0.4 mm resolution, 3-D tracking of charged particles. The incident direction of fast neutrons, En > 0.5 MeV, are reconstructed from the momenta and energies of the proton and triton fragments resulting from (sup 3)He(n,p) (sup 3)H interactions in the 3-DTI volume. The performance of the NIC from laboratory and accelerator tests is presented.
An Optimal Control Modification to Model-Reference Adaptive Control for Fast Adaptation
NASA Technical Reports Server (NTRS)
Nguyen, Nhan T.; Krishnakumar, Kalmanje; Boskovic, Jovan
2008-01-01
This paper presents a method that can achieve fast adaptation for a class of model-reference adaptive control. It is well-known that standard model-reference adaptive control exhibits high-gain control behaviors when a large adaptive gain is used to achieve fast adaptation in order to reduce tracking error rapidly. High gain control creates high-frequency oscillations that can excite unmodeled dynamics and can lead to instability. The fast adaptation approach is based on the minimization of the squares of the tracking error, which is formulated as an optimal control problem. The necessary condition of optimality is used to derive an adaptive law using the gradient method. This adaptive law is shown to result in uniform boundedness of the tracking error by means of the Lyapunov s direct method. Furthermore, this adaptive law allows a large adaptive gain to be used without causing undesired high-gain control effects. The method is shown to be more robust than standard model-reference adaptive control. Simulations demonstrate the effectiveness of the proposed method.
NASA Astrophysics Data System (ADS)
Zhang, Jianqiao; Ye, Dong; Sun, Zhaowei; Liu, Chuang
2018-02-01
This paper presents a robust adaptive controller integrated with an extended state observer (ESO) to solve coupled spacecraft tracking maneuver in the presence of model uncertainties, external disturbances, actuator uncertainties including magnitude deviation and misalignment, and even actuator saturation. More specifically, employing the exponential coordinates on the Lie group SE(3) to describe configuration tracking errors, the coupled six-degrees-of-freedom (6-DOF) dynamics are developed for spacecraft relative motion, in which a generic fully actuated thruster distribution is considered and the lumped disturbances are reconstructed by using anti-windup technique. Then, a novel ESO, developed via second order sliding mode (SOSM) technique and adding linear correction terms to improve the performance, is designed firstly to estimate the disturbances in finite time. Based on the estimated information, an adaptive fast terminal sliding mode (AFTSM) controller is developed to guarantee the almost global asymptotic stability of the resulting closed-loop system such that the trajectory can be tracked with all the aforementioned drawbacks addressed simultaneously. Finally, the effectiveness of the controller is illustrated through numerical examples.
Tracking weight change, insulin resistance, stress, and aerobic fitness over 4 years of college.
Hopper, Mari K; Moninger, Shana Lynn
2017-01-01
To determine if weight gain is accompanied by development of insulin resistance (IR) during 4 years in college. Two cohorts of college students were enrolled in fall semesters 2009 and 2010 and tracked for 4 years. Following a 12-hour fast, subjects reported for measurement of body mass index (BMI), perceived stress (PSS), aerobic fitness, and blood glucose, insulin, and lipids. In the first year, 33% of subjects were overweight or obese, and 20% were hyperinsulinemic. Year 4 had 29 remaining subjects with disproportionate attrition of overweight and obese individuals. Just over half the subjects gained weight (WI), whereas nearly 30% lost considerable amounts (WD). WD showed significant decline in fasting insulin, low-density lipoprotein (LDL) cholesterol, and PSS from year 1. WI was primarily highly fit men who did not demonstrate increased IR. WI was not associated with IR over 4 years of college.
The design of a fast Level 1 Track trigger for the ATLAS High Luminosity Upgrade
NASA Astrophysics Data System (ADS)
Miller Allbrooke, Benedict Marc; ATLAS Collaboration
2017-10-01
The ATLAS experiment at the high-luminosity LHC will face a five-fold increase in the number of interactions per collision relative to the ongoing Run 2. This will require a proportional improvement in rejection power at the earliest levels of the detector trigger system, while preserving good signal efficiency, due to the increase in the likelihood of individual trigger thresholds being passed as a result of pile-up related activity. One critical aspect of this improvement will be the implementation of precise track reconstruction, through which sharper turn-on curves, b-tagging and tau-tagging techniques can in principle be implemented. The challenge of such a project comes in the development of a fast, precise custom electronic device integrated in the hardware-based first trigger level of the experiment, with repercussions propagating as far as the detector read-out philosophy.
Wied, Christian; Thomsen, Morten G; Kallemose, Thomas; Myhrmann, Lis; Jensen, Lotte S; Husted, Henrik; Troelsen, Anders
2015-10-01
Fast-track TKA has significantly shortened the time available for physiotherapists to optimize knee ROM before discharge. Safety aspects concerning knee stiffness and the need for manipulation in a fast-track setting need to be illuminated. The study aims were to analyze if fast-track TKA can be considered safe considering rates of knee manipulation and if there is an association between knee ROM at time of discharge and the need for later manipulation. Primary TKAs operated in 2011 at our institution were eligible for inclusion. The study group consisted of 359 TKAs. Manipulation of the knee was performed in 21 of 359 TKAs (5.8%). Seventy-one percent were discharged with a flexion ≥70° combined with an extension deficit of ≤10°. The occurrence of MUA for these patients was 4.3%. The prevalence of knee manipulation showed a statistically significant association with the achieved knee flexion at discharge (p=0.02). Median length of stay was two days. Compared with literature findings fast-track TKA surgery may be considered safe based on the acceptable rate of knee manipulations after TKA (5.8%). We suggest ROM of ≥70° flexion combined with an extension deficit of ≤10° as an "optimal-zone" for ROM at discharge. The reason for this is the low occurrence of MUA (4.3%) in relation to the large amount of TKAs it represents (71%). The indication for MUA is multifactorial and ROM at discharge serves only as an indicator of later MUA risk. Copyright © 2015 Elsevier B.V. All rights reserved.
FAST: A fully asynchronous and status-tracking pattern for geoprocessing services orchestration
NASA Astrophysics Data System (ADS)
Wu, Huayi; You, Lan; Gui, Zhipeng; Gao, Shuang; Li, Zhenqiang; Yu, Jingmin
2014-09-01
Geoprocessing service orchestration (GSO) provides a unified and flexible way to implement cross-application, long-lived, and multi-step geoprocessing service workflows by coordinating geoprocessing services collaboratively. Usually, geoprocessing services and geoprocessing service workflows are data and/or computing intensive. The intensity feature may make the execution process of a workflow time-consuming. Since it initials an execution request without blocking other interactions on the client side, an asynchronous mechanism is especially appropriate for GSO workflows. Many critical problems remain to be solved in existing asynchronous patterns for GSO including difficulties in improving performance, status tracking, and clarifying the workflow structure. These problems are a challenge when orchestrating performance efficiency, making statuses instantly available, and constructing clearly structured GSO workflows. A Fully Asynchronous and Status-Tracking (FAST) pattern that adopts asynchronous interactions throughout the whole communication tier of a workflow is proposed for GSO. The proposed FAST pattern includes a mechanism that actively pushes the latest status to clients instantly and economically. An independent proxy was designed to isolate the status tracking logic from the geoprocessing business logic, which assists the formation of a clear GSO workflow structure. A workflow was implemented in the FAST pattern to simulate the flooding process in the Poyang Lake region. Experimental results show that the proposed FAST pattern can efficiently tackle data/computing intensive geoprocessing tasks. The performance of all collaborative partners was improved due to the asynchronous mechanism throughout communication tier. A status-tracking mechanism helps users retrieve the latest running status of a GSO workflow in an efficient and instant way. The clear structure of the GSO workflow lowers the barriers for geospatial domain experts and model designers to compose asynchronous GSO workflows. Most importantly, it provides better support for locating and diagnosing potential exceptions.
Telemedicine support shortens length of stay after fast-track hip replacement.
Vesterby, Martin Svoldgaard; Pedersen, Preben Ulrich; Laursen, Malene; Mikkelsen, Søren; Larsen, Jens; Søballe, Kjeld; Jørgensen, Lene Bastrup
2017-02-01
Background and purpose - Telemedicine could allow patients to be discharged more quickly after surgery and contribute to improve fast-track procedures without compromising quality, patient safety, functionality, anxiety, or other patient-perceived parameters. We investigated whether using telemedicine support (TMS) would permit hospital discharge after 1 day without loss of self-assessed quality of life, loss of functionality, increased anxiety, increased rates of re-admission, or increased rates of complications after hip replacement. Patients and methods - We performed a randomized controlled trial involving 72 Danish patients in 1 region who were referred for elective fast-track total hip replacement between August 2009 and March 2011 (654 were screened for eligibility). Half of the patients received a telemedicine solution connected to their TV. The patients were followed until 1 year after surgery. Results - Length of stay was reduced from 2.1 days (95% CI: 2.0-2.3) to 1.1 day (CI: 0.9-1.4; p < 0.001) with the TMS intervention. Health-related quality of life increased in both groups, but there were no statistically significant differences between groups. There were also no statistically significant differences between groups regarding timed up-and-go test and Oxford hip score at 3-month follow-up. At 12-month follow-up, the rates of complications and re-admissions were similar between the groups, but the number of postoperative hospital contacts was lower in the TMS group. Interpretation - Length of postoperative stay was shortened in patients with the TMS solution, without compromising patient-perceived or clinical parameters in patients undergoing elective fast-track surgery. These results indicate that telemedicine can be of value in fast-track treatment of patients undergoing total hip replacement.
A Real-Time Localization System for an Endoscopic Capsule Using Magnetic Sensors †
Pham, Duc Minh; Aziz, Syed Mahfuzul
2014-01-01
Magnetic sensing technology offers an attractive alternative for in vivo tracking with much better performance than RF and ultrasound technologies. In this paper, an efficient in vivo magnetic tracking system is presented. The proposed system is intended to localize an endoscopic capsule which delivers biomarkers around specific locations of the gastrointestinal (GI) tract. For efficiently localizing a magnetic marker inside the capsule, a mathematical model has been developed for the magnetic field around a cylindrical magnet and used with a localization algorithm that provides minimum error and fast computation. The proposed tracking system has much reduced complexity compared to the ones reported in the literature to date. Laboratory tests and in vivo animal trials have demonstrated the suitability of the proposed system for tracking a magnetic marker with expected accuracy. PMID:25379813
Development of Ultra-Fast Silicon Detectors for 4D tracking
NASA Astrophysics Data System (ADS)
Staiano, A.; Arcidiacono, R.; Boscardin, M.; Dalla Betta, G. F.; Cartiglia, N.; Cenna, F.; Ferrero, M.; Ficorella, F.; Mandurrino, M.; Obertino, M.; Pancheri, L.; Paternoster, G.; Sola, V.
2017-12-01
In this contribution we review the progress towards the development of a novel type of silicon detectors suited for tracking with a picosecond timing resolution, the so called Ultra-Fast Silicon Detectors. The goal is to create a new family of particle detectors merging excellent position and timing resolution with GHz counting capabilities, very low material budget, radiation resistance, fine granularity, low power, insensitivity to magnetic field, and affordability. We aim to achieve concurrent precisions of ~ 10 ps and ~ 10 μm with a 50 μm thick sensor. Ultra-Fast Silicon Detectors are based on the concept of Low-Gain Avalanche Detectors, which are silicon detectors with an internal multiplication mechanism so that they generate a signal which is factor ~10 larger than standard silicon detectors. The basic design of UFSD consists of a thin silicon sensor with moderate internal gain and pixelated electrodes coupled to full custom VLSI chip. An overview of test beam data on time resolution and the impact on this measurement of radiation doses at the level of those expected at HL-LHC is presented. First I-V and C-V measurements on a new FBK sensor production of UFSD, 50 μm thick, with B and Ga, activated at two diffusion temperatures, with and without C co-implantation (in Low and High concentrations), and with different effective doping concentrations in the Gain layer, are shown. Perspectives on current use of UFSD in HEP experiments (UFSD detectors have been installed in the CMS-TOTEM Precision Protons Spectrometer for the forward physics tracking, and are currently taking data) and proposed applications for a MIP timing layer in the HL-LHC upgrade are briefly discussed.
Real-time tracking and fast retrieval of persons in multiple surveillance cameras of a shopping mall
NASA Astrophysics Data System (ADS)
Bouma, Henri; Baan, Jan; Landsmeer, Sander; Kruszynski, Chris; van Antwerpen, Gert; Dijk, Judith
2013-05-01
The capability to track individuals in CCTV cameras is important for e.g. surveillance applications at large areas such as train stations, airports and shopping centers. However, it is laborious to track and trace people over multiple cameras. In this paper, we present a system for real-time tracking and fast interactive retrieval of persons in video streams from multiple static surveillance cameras. This system is demonstrated in a shopping mall, where the cameras are positioned without overlapping fields-of-view and have different lighting conditions. The results show that the system allows an operator to find the origin or destination of a person more efficiently. The misses are reduced with 37%, which is a significant improvement.
Research on Precision Tracking on Fast Steering Mirror and Control Strategy
NASA Astrophysics Data System (ADS)
Di, Lin; Yi-ming, Wu; Fan, Zhu
2018-01-01
Fast steering mirror is a device used for controlling the beam direction precisely. Due to the short travel of the push-pull FSM, a compound fast steering mirror system driven by both limited-angle voice coil motor and push-pull FSM together is proposed. In the compound FSM system, limited-angle voice coil motor quickly swings at wide angle, while the push-pull FSM do high frequency movement in a small range, which provides the system with the high bandwidth and long travel. In the control strategy, the method of combining feed-forward control in Kalman filtering with auto-disturbance rejection control is used to improve trajectory tracking accuracy. The simulation result shows that tracking accuracy measured by the compound method can be improved by more than 5 times than that of the conventional PID.
ERIC Educational Resources Information Center
Blackett, Alexander David; Evans, Adam; Piggott, David
2017-01-01
At the beginning of the 2013/2014 season in England and Wales, 90 head coaches of the 92 men's national professional football league clubs and 20 of the 22 men's professional rugby union clubs had tenure as a professional elite player in their respective sports. Moreover, Rynne [(2014). "'Fast track' and 'traditional path' coaches:…
Omitted Costs, Inflated Benefits: Renewable Energy Policy in Ontario
ERIC Educational Resources Information Center
Gallant, Parker; Fox, Glenn
2011-01-01
The government of Ontario has adopted wind energy development as an alternative energy source. It enacted the Green Energy and Economy Act, May 2009, with the intention to fast track the approval process regarding industrial wind turbines. The Act legislated a centralized decision making process while removing local jurisdictional authority.…
Fostering Solutions: Bringing Brief-Therapy Principles and Practices to the Child Welfare System
ERIC Educational Resources Information Center
Flemons, Douglas; Liscio, Michele; Gordon, Arlene Brett; Hibel, James; Gutierrez-Hersh, Annette; Rebholz, Cynthia L.
2010-01-01
This article describes a 15-month university-community collaboration that was designed to fast-track children out of foster care. The developers of the project initiated resource-oriented "systems facilitations," allowing wraparound professionals and families to come together in large meetings to solve problems and find solutions. Families also…
The Impact of Tutoring on Early Reading Achievement for Children with and without Attention Problems
ERIC Educational Resources Information Center
Rabiner, David L.; Malone, Patrick S.
2004-01-01
This study examined whether the benefits of reading tutoring in first grade were moderated by children's level of attention problems. Participants were 581 children from the intervention and control samples of Fast Track, a longitudinal multisite investigation of the development and prevention of conduct problems. Standardized reading achievement…
Prototype of a single probe Compton camera for laparoscopic surgery
NASA Astrophysics Data System (ADS)
Koyama, A.; Nakamura, Y.; Shimazoe, K.; Takahashi, H.; Sakuma, I.
2017-02-01
Image-guided surgery (IGS) is performed using a real-time surgery navigation system with three-dimensional (3D) position tracking of surgical tools. IGS is fast becoming an important technology for high-precision laparoscopic surgeries, in which the field of view is limited. In particular, recent developments in intraoperative imaging using radioactive biomarkers may enable advanced IGS for supporting malignant tumor removal surgery. In this light, we develop a novel intraoperative probe with a Compton camera and a position tracking system for performing real-time radiation-guided surgery. A prototype probe consisting of Ce :Gd3 Al2 Ga3 O12 (GAGG) crystals and silicon photomultipliers was fabricated, and its reconstruction algorithm was optimized to enable real-time position tracking. The results demonstrated the visualization capability of the radiation source with ARM = ∼ 22.1 ° and the effectiveness of the proposed system.
Success factors for reducing maternal and child mortality
Schweitzer, Julian; Bishai, David; Chowdhury, Sadia; Caramani, Daniele; Frost, Laura; Cortez, Rafael; Daelmans, Bernadette; de Francisco, Andres; Adam, Taghreed; Cohen, Robert; Alfonso, Y Natalia; Franz-Vasdeki, Jennifer; Saadat, Seemeen; Pratt, Beth Anne; Eugster, Beatrice; Bandali, Sarah; Venkatachalam, Pritha; Hinton, Rachael; Murray, John; Arscott-Mills, Sharon; Axelson, Henrik; Maliqi, Blerta; Sarker, Intissar; Lakshminarayanan, Rama; Jacobs, Troy; Jacks, Susan; Mason, Elizabeth; Ghaffar, Abdul; Mays, Nicholas; Presern, Carole; Bustreo, Flavia
2014-01-01
Abstract Reducing maternal and child mortality is a priority in the Millennium Development Goals (MDGs), and will likely remain so after 2015. Evidence exists on the investments, interventions and enabling policies required. Less is understood about why some countries achieve faster progress than other comparable countries. The Success Factors for Women’s and Children’s Health studies sought to address this knowledge gap using statistical and econometric analyses of data from 144 low- and middle-income countries (LMICs) over 20 years; Boolean, qualitative comparative analysis; a literature review; and country-specific reviews in 10 fast-track countries for MDGs 4 and 5a. There is no standard formula – fast-track countries deploy tailored strategies and adapt quickly to change. However, fast-track countries share some effective approaches in addressing three main areas to reduce maternal and child mortality. First, these countries engage multiple sectors to address crucial health determinants. Around half the reduction in child mortality in LMICs since 1990 is the result of health sector investments, the other half is attributed to investments made in sectors outside health. Second, these countries use strategies to mobilize partners across society, using timely, robust evidence for decision-making and accountability and a triple planning approach to consider immediate needs, long-term vision and adaptation to change. Third, the countries establish guiding principles that orient progress, align stakeholder action and achieve results over time. This evidence synthesis contributes to global learning on accelerating improvements in women’s and children’s health towards 2015 and beyond. PMID:25110379
Success factors for reducing maternal and child mortality.
Kuruvilla, Shyama; Schweitzer, Julian; Bishai, David; Chowdhury, Sadia; Caramani, Daniele; Frost, Laura; Cortez, Rafael; Daelmans, Bernadette; de Francisco, Andres; Adam, Taghreed; Cohen, Robert; Alfonso, Y Natalia; Franz-Vasdeki, Jennifer; Saadat, Seemeen; Pratt, Beth Anne; Eugster, Beatrice; Bandali, Sarah; Venkatachalam, Pritha; Hinton, Rachael; Murray, John; Arscott-Mills, Sharon; Axelson, Henrik; Maliqi, Blerta; Sarker, Intissar; Lakshminarayanan, Rama; Jacobs, Troy; Jack, Susan; Jacks, Susan; Mason, Elizabeth; Ghaffar, Abdul; Mays, Nicholas; Presern, Carole; Bustreo, Flavia
2014-07-01
Reducing maternal and child mortality is a priority in the Millennium Development Goals (MDGs), and will likely remain so after 2015. Evidence exists on the investments, interventions and enabling policies required. Less is understood about why some countries achieve faster progress than other comparable countries. The Success Factors for Women's and Children's Health studies sought to address this knowledge gap using statistical and econometric analyses of data from 144 low- and middle-income countries (LMICs) over 20 years; Boolean, qualitative comparative analysis; a literature review; and country-specific reviews in 10 fast-track countries for MDGs 4 and 5a. There is no standard formula--fast-track countries deploy tailored strategies and adapt quickly to change. However, fast-track countries share some effective approaches in addressing three main areas to reduce maternal and child mortality. First, these countries engage multiple sectors to address crucial health determinants. Around half the reduction in child mortality in LMICs since 1990 is the result of health sector investments, the other half is attributed to investments made in sectors outside health. Second, these countries use strategies to mobilize partners across society, using timely, robust evidence for decision-making and accountability and a triple planning approach to consider immediate needs, long-term vision and adaptation to change. Third, the countries establish guiding principles that orient progress, align stakeholder action and achieve results over time. This evidence synthesis contributes to global learning on accelerating improvements in women's and children's health towards 2015 and beyond.
Irradiation control parameters for computer-assisted laser photocoagulation of the retina
NASA Astrophysics Data System (ADS)
Naess, Espen; Molvik, Torstein; Barrett, Steven F.; Wright, Cameron H. G.; de Graaf, Peter W.
2001-06-01
A system for robotically assisted retinal surgery has been developed to rapidly and safely place lesions on the retina for photocoagulation therapy. This system provides real- time, motion stabilized lesion placement for typical irradiation times of 100 ms. The system consists of three main subsystems: a global, digital-based tracking subsystem; a fast, local analog tracking subsystem; and a confocal reflectance subsystem to control lesion parameters dynamically. We have reported on these subsystems in previous SPIE presentations. This paper concentrates on the development of the second hybrid system prototype. Considerable progress has been made toward reducing the footprint of the optical system, simplifying the user interface, fully characterizing the analog tracking system and using measurable lesion reflectance growth parameters to develop a noninvasive method to infer lesion depth. This method will allow dynamic control of laser dosimetry to provide similar lesions across the non-uniform retinal surface. These system improvements and progress toward a clinically significant system are covered in detail within this paper.
The use of integrated focal plane array technologies in laser microsatellite networks
NASA Astrophysics Data System (ADS)
Arnon, Shlomi
2004-10-01
Clustering micro satellites in cooperative fly formation constellations leads to high-performance space systems. The only way to achieve high-speed communication between the satellites is by a laser beam with a narrow divergence angle. In order to make the communication successful three types of focal plane detector arrays are required in the communication terminal: acquisition, tracking and communication detector arrays. The acquisition detector array is used to acquire the neighbor satellite using a wide field-of-view telescope. The tracking detector provides fast, real time and accurate direction location of the neighbor satellite. Based on the information from the acquisition and tracking detectors the receiver and transmitter maintain line of sight. The development of large, fast and very sensitive focal plane detector arrays makes it possible to implement the acquisition, tracking and communication with only one focal plane detector array. By doing so it is possible to reduce dramatically the size, weight, and cost of the optics and electronics which leads to lightweight communication terminals. As a result, the satellites are smaller and lighter, which reduces the space mission cost and increases the booster efficiency. In this paper we will present an overview of the concept of integrated focal plane arrays for laser satellite communication. We also present simulation results based on real system parameters and compare different implementation options.
Visual tracking using objectness-bounding box regression and correlation filters
NASA Astrophysics Data System (ADS)
Mbelwa, Jimmy T.; Zhao, Qingjie; Lu, Yao; Wang, Fasheng; Mbise, Mercy
2018-03-01
Visual tracking is a fundamental problem in computer vision with extensive application domains in surveillance and intelligent systems. Recently, correlation filter-based tracking methods have shown a great achievement in terms of robustness, accuracy, and speed. However, such methods have a problem of dealing with fast motion (FM), motion blur (MB), illumination variation (IV), and drifting caused by occlusion (OCC). To solve this problem, a tracking method that integrates objectness-bounding box regression (O-BBR) model and a scheme based on kernelized correlation filter (KCF) is proposed. The scheme based on KCF is used to improve the tracking performance of FM and MB. For handling drift problem caused by OCC and IV, we propose objectness proposals trained in bounding box regression as prior knowledge to provide candidates and background suppression. Finally, scheme KCF as a base tracker and O-BBR are fused to obtain a state of a target object. Extensive experimental comparisons of the developed tracking method with other state-of-the-art trackers are performed on some of the challenging video sequences. Experimental comparison results show that our proposed tracking method outperforms other state-of-the-art tracking methods in terms of effectiveness, accuracy, and robustness.
Li, Mengfei; Hansen, Christian; Rose, Georg
2017-09-01
Electromagnetic tracking systems (EMTS) have achieved a high level of acceptance in clinical settings, e.g., to support tracking of medical instruments in image-guided interventions. However, tracking errors caused by movable metallic medical instruments and electronic devices are a critical problem which prevents the wider application of EMTS for clinical applications. We plan to introduce a method to dynamically reduce tracking errors caused by metallic objects in proximity to the magnetic sensor coil of the EMTS. We propose a method using ramp waveform excitation based on modeling the conductive distorter as a resistance-inductance circuit. Additionally, a fast data acquisition method is presented to speed up the refresh rate. With the current approach, the sensor's positioning mean error is estimated to be 3.4, 1.3 and 0.7 mm, corresponding to a distance between the sensor and center of the transmitter coils' array of up to 200, 150 and 100 mm, respectively. The sensor pose error caused by different medical instruments placed in proximity was reduced by the proposed method to a level lower than 0.5 mm in position and [Formula: see text] in orientation. By applying the newly developed fast data acquisition method, we achieved a system refresh rate up to approximately 12.7 frames per second. Our software-based approach can be integrated into existing medical EMTS seamlessly with no change in hardware. It improves the tracking accuracy of clinical EMTS when there is a metallic object placed near the sensor coil and has the potential to improve the safety and outcome of image-guided interventions.
Progress in high temperature speckle-shift strain measurement system
NASA Technical Reports Server (NTRS)
Lant, Christian T.; Barranger, John P.
1990-01-01
A fast, easy to use speckle tracking system is under development for the speckle-shift strain measurement technique. Preliminary correlation tests on wire specimens show strong correlations of well-developed speckle patterns. Stable cross-correlations were obtained from a tungsten filament at 2480 C. An analysis of the optical system determines the minimum required sampling frequency of the speckle pattern to be 2.55 pixels per speckle.
NASA Astrophysics Data System (ADS)
Zhang, Aiying; Jia, Bochao; Wang, Yu-Ping
2018-03-01
Adolescence is a transitional period between childhood and adulthood with physical changes, as well as increasing emotional activity. Studies have shown that the emotional sensitivity is related to a second dramatical brain growth. However, there is little focus on the trend of brain development during this period. In this paper, we aim to track the functional brain connectivity development in adolescence using resting state fMRI (rs-fMRI), which amounts to a time-series analysis problem. Most existing methods either require the time point to be fairly long or are only applicable to small graphs. To this end, we adapted a fast Bayesian integrative analysis (FBIA) to address the short time-series difficulty, and combined with adaptive sum of powered score (aSPU) test for group difference. The data we used are the resting state fMRI (rs-fMRI) obtained from the publicly available Philadelphia Neurodevelopmental Cohort (PNC). They include 861 individuals aged 8-22 years who were divided into five different adolescent stages. We summarized the networks with global measurements: segregation and integration, and provided full brain functional connectivity pattern in various stages of adolescence. Moreover, our research revealed several brain functional modules development trends. Our results are shown to be both statistically and biologically significant.
A simple apparatus for quick qualitative analysis of CR39 nuclear track detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gautier, D. C.; Kline, J. L.; Flippo, K. A.
2008-10-15
Quantifying the ion pits in Columbia Resin 39 (CR39) nuclear track detector from Thomson parabolas is a time consuming and tedious process using conventional microscope based techniques. A simple inventive apparatus for fast screening and qualitative analysis of CR39 detectors has been developed, enabling efficient selection of data for a more detailed analysis. The system consists simply of a green He-Ne laser and a high-resolution digital single-lens reflex camera. The laser illuminates the edge of the CR39 at grazing incidence and couples into the plastic, acting as a light pipe. Subsequently, the laser illuminates all ion tracks on the surface.more » A high-resolution digital camera is used to photograph the scattered light from the ion tracks, enabling one to quickly determine charge states and energies measured by the Thomson parabola.« less
NASA Astrophysics Data System (ADS)
Yue, Fengfa; Li, Xingfei; Chen, Cheng; Tan, Wenbin
2017-12-01
In order to improve the control accuracy and stability of opto-electronic tracking system fixed on reef or airport under friction and external disturbance conditions, adaptive integral backstepping sliding mode control approach with friction compensation is developed to achieve accurate and stable tracking for fast moving target. The nonlinear observer and slide mode controller based on modified LuGre model with friction compensation can effectively reduce the influence of nonlinear friction and disturbance of this servo system. The stability of the closed-loop system is guaranteed by Lyapunov theory. The steady-state error of the system is eliminated by integral action. The adaptive integral backstepping sliding mode controller and its performance are validated by a nonlinear modified LuGre dynamic model of the opto-electronic tracking system in simulation and practical experiments. The experiment results demonstrate that the proposed controller can effectively realise the accuracy and stability control of opto-electronic tracking system.
Docimo, A B; Pronovost, P J; Davis, R O; Concordia, E B; Gabrish, C M; Adessa, M S; Bessman, E
2000-09-01
In 1998 the emergency department (ED) Work Group at Johns Hopkins Bayview Medical Center (Baltimore) worked to reinvigorate the fast-track program within the ED to improve throughput for patients with minor illnesses and injuries who present for care. There had been two prior unsuccessful attempts to overhaul the fast-track process. The work group used a change model intended to improve both processes and relationships for complex organizational problems that span departments and functional units. Before the first work group meeting, the work group evaluated the institutional commitment to address the issue. The next step was to find data to fully understand the issues and establish a baseline for evaluating improvements--for example, patients with minor illnesses and injuries had excessively long total ED (registration to discharge) times: 5 hours 57 minutes on average for nonacute patients. ONLINE AND OFFLINE MEETINGS: The work group identified process problems, but relationship barriers became evident as the new processes were discussed. Yet offline work was needed to minimize the potential for online surprises. The work group leaders met separately in small groups with nursing staff, lab staff, x-ray staff, registrars, and physician's assistants to inform them of data, obtain input about process changes, and address any potential concerns. The group conducted four tests of change (using Plan-Do-Study-Act cycles) to eliminate the root causes of slow turnaround identified previously. Total ED time decreased to an average of 1 hour 47 minutes; the practice of placing nonacute patients in fast track before all higher-acuity patients were seen gained acceptance. The percentage of higher-acuity patients sent to fast track decreased from 17% of all patients seen in fast track in January 1998 to 8.5% by February 1999. Patients with minor illnesses and injuries no longer had to wait behind higher-acuity patients just to be registered. The average wait for registration decreased from 42 minutes in January 1998 to 14 minutes in February 1999. Physician's assistant, nursing, and technician staff all report improved working relationships and feeling a team spirit. The offline component of the integrated model helped to improve organizational relationships and dialogue among team members, thereby facilitating the effectiveness of online efforts to improve processes. This model has also been applied to improve patient registration (revenue recovery) and the emergency transfer and admissions process.
BEAM DYNAMICS ANALYSIS FOR THE ULTRA-FAST KICKER IN CIRCULAR COOLER RING OF JLEIC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Yulu; Wang, Haipeng; Rimmer, Robert A.
An ultra-fast kicker system consisting of four quarter wavelength resonator based deflecting cavities was developed that simultaneously resonates at 10 subharmonic modes of the 476.3MHz bunch repetition frequency. Thus every 10th bunch in the bunch train will experience a transverse kick while all the other bunches are undisturbed. This fast kicker is being developed for the Energy Recovery Linac (ERL) based electron Circular Cooler Ring (CCR) in the proposed Jefferson Lab Electron Ion Collider (JLEIC, previously MEIC). The electron bunches can be reused 10-30 turns thus the beam current in the ERL can be reduced to 1/10 - 1/30 (150mAmore » - 50mA) of the cooling bunch current (1.5A). In this paper, several methods to synthesize such a kicker waveform and the comparison made by the beam dynamics tracking in Elegant will be discussed.« less
FAST TRACK COMMUNICATION: Quantization over boson operator spaces
NASA Astrophysics Data System (ADS)
Prosen, Tomaž; Seligman, Thomas H.
2010-10-01
The framework of third quantization—canonical quantization in the Liouville space—is developed for open many-body bosonic systems. We show how to diagonalize the quantum Liouvillean for an arbitrary quadratic n-boson Hamiltonian with arbitrary linear Lindblad couplings to the baths and, as an example, explicitly work out a general case of a single boson.
ERIC Educational Resources Information Center
Gilbert, David H.
2012-01-01
Purpose: The purpose of this paper is to examine the notion of designing and developing applied, industry-engaged learning environments that embrace ambiguity and uncertainty in overcoming pedagogical inertia in educating young entrepreneurs and innovators. The research reported on proposes a solution to the dual expectations of producing…
1997-03-01
found in several different terms: Deep selection, early promotion or fast-track promotion. The latter is common lingo of labor economics . Throughout...this thesis the military terms will be used interchangeably, "fast-track promotion" will be used as term in a labor economics context. because they put...found that FITREP 5 Holt: Managerial Principles & Practices, Ehrenberg/Smith: Modern Labor Economics , WEST Series of Organizational Behaviour, as a few
Thorium-uranium fission radiography
NASA Technical Reports Server (NTRS)
Haines, E. L.; Weiss, J. R.; Burnett, D. S.; Woolum, D. S.
1976-01-01
Results are described for studies designed to develop routine methods for in-situ measurement of the abundance of Th and U on a microscale in heterogeneous samples, especially rocks, using the secondary high-energy neutron flux developed when the 650 MeV proton beam of an accelerator is stopped in a 42 x 42 cm diam Cu cylinder. Irradiations were performed at three different locations in a rabbit tube in the beam stop area, and thick metal foils of Bi, Th, and natural U as well as polished silicate glasses of known U and Th contents were used as targets and were placed in contact with mica which served as a fission track detector. In many cases both bare and Cd-covered detectors were exposed. The exposed mica samples were etched in 48% HF and the fission tracks counted by conventional transmitted light microscopy. Relative fission cross sections are examined, along with absolute Th track production rates, interaction tracks, and a comparison of measured and calculated fission rates. The practicality of fast neutron radiography revealed by experiments to data is discussed primarily for Th/U measurements, and mixtures of other fissionable nuclei are briefly considered.
Quintana-Díaz, Manuel; Fabra-Cadenas, Sara; Gómez-Ramírez, Susana; Martínez-Virto, Ana; García-Erce, José A.; Muñoz, Manuel
2016-01-01
Background Clinically significant anaemia, requiring red blood cell transfusions, is frequently observed in Emergency Departments (ED). To optimise blood product use, we developed a clinical protocol for the management of iron-deficiency anaemia in a fast-track anaemia clinic within the ED. Materials and methods From November 2010 to January 2014, patients presenting with sub-acute, moderate-to-severe anaemia (haemoglobin [Hb] <11 g/dL) and confirmed or suspected iron deficiency were referred to the fast-track anaemia clinic. Those with absolute or functional iron deficiency were given intravenous (IV) ferric carboxymaltose 500–1,000 mg/week and were reassessed 4 weeks after receiving the total iron dose. The primary study outcome was the haematological response (Hb≥12 g/dL and/or Hb increment ≥2 g/dL). Changes in blood and iron parameters, transfusion rates and IV iron-related adverse drug effects were secondary outcomes. Results Two hundred and two anaemic patients with iron deficiency (150 women/52 men; mean age, 64 years) were managed in the fast-track anaemia clinic, and received a median IV iron dose of 1,500 mg (1,000–2,000 mg). Gastro-intestinal (44%) or gynaecological (26%) bleeding was the most frequent cause of the anaemia. At follow-up (183 patients), the mean Hb increment was 3.9±2.2 g/dL; 84% of patients were classified as responders and blood and iron parameters normalised in 90%. During follow-up, 35 (17%) patients needed transfusions (2 [range: 1–3] units per patient) because they had low Hb levels, symptoms of anaemia and/or were at risk. Eight mild and one moderate, self-limited adverse drug effects were witnessed. Discussion Our data support the feasibility of a clinical protocol for management of sub-acute anaemia with IV iron in the ED. IV iron was efficacious, safe and well tolerated. Early management of anaemia will improve the use of blood products in the ED. PMID:26674819
Fast-track eligibility of geriatric patients undergoing short urologic surgery procedures.
Fredman, Brian; Sheffer, Offer; Zohar, Edna; Paruta, Irena; Richter, Santiago; Jedeikin, Robert; White, Paul F
2002-03-01
Our primary objective was to assess the feasibility of geriatric patients (>65 yr) bypassing the postanesthesia care unit (PACU) after ambulatory surgery. A secondary objective was to compare recovery profiles when using three different maintenance anesthetics. Ninety ASA physical status I--III consenting outpatients (>65 yr) undergoing short urologic procedures were randomly assigned to one of three anesthetic treatment groups. After a standardized induction with fentanyl and propofol, anesthesia was maintained with propofol (75-150 microg center dot kg(-1) center dot min(-1) IV), isoflurane (0.7%-1.2% end tidal), or desflurane (3%-6% end tidal), in combination with nitrous oxide 70% in oxygen. In all three groups, the primary anesthetic was titrated to maintain an electroencephalographic-bispectral index value of 60-65. Recovery times, postanesthesia recovery scores, and therapeutic interventions in the PACU were recorded. Although emergence times were similar in the three groups, the time to achieve a fast-track discharge score of 14 was significantly shorter in patients receiving desflurane compared with propofol and isoflurane (22 +/- 23 vs 33 +/- 25 and 44 +/- 36 min, respectively). On arrival in the PACU, a significantly larger percentage of patients receiving desflurane were judged to be fast-track eligible compared with those receiving either isoflurane and propofol (73% vs 43% and 44%, respectively). The number of therapeutic interventions in the PACU was also significantly larger in the Isoflurane group when compared with the Propofol and Desflurane groups (21 vs 11 and 7, respectively). In conclusion, use of desflurane for maintenance of anesthesia should facilitate PACU bypass ("fast-tracking") of geriatric patients undergoing short urologic procedures. Geriatric outpatients undergoing brief urologic procedures more rapidly achieve fast-tracking discharge criteria after desflurane (versus isoflurane and propofol) anesthesia. Use of isoflurane was also associated with an increased need for nursing interventions in the early recovery period compared with desflurane and propofol.
A novel approach to Hough Transform for implementation in fast triggers
NASA Astrophysics Data System (ADS)
Pozzobon, Nicola; Montecassiano, Fabio; Zotto, Pierluigi
2016-10-01
Telescopes of position sensitive detectors are common layouts in charged particles tracking, and programmable logic devices, such as FPGAs, represent a viable choice for the real-time reconstruction of track segments in such detector arrays. A compact implementation of the Hough Transform for fast triggers in High Energy Physics, exploiting a parameter reduction method, is proposed, targeting the reduction of the needed storage or computing resources in current, or next future, state-of-the-art FPGA devices, while retaining high resolution over a wide range of track parameters. The proposed approach is compared to a Standard Hough Transform with particular emphasis on their application to muon detectors. In both cases, an original readout implementation is modeled.
NASA Technical Reports Server (NTRS)
Agurok, Llya
2013-01-01
The Hyperspectral Imager-Tracker (HIT) is a technique for visualization and tracking of low-contrast, fast-moving objects. The HIT architecture is based on an innovative and only recently developed concept in imaging optics. This innovative architecture will give the Light Prescriptions Innovators (LPI) HIT the possibility of simultaneously collecting the spectral band images (hyperspectral cube), IR images, and to operate with high-light-gathering power and high magnification for multiple fast- moving objects. Adaptive Spectral Filtering algorithms will efficiently increase the contrast of low-contrast scenes. The most hazardous parts of a space mission are the first stage of a launch and the last 10 kilometers of the landing trajectory. In general, a close watch on spacecraft operation is required at distances up to 70 km. Tracking at such distances is usually associated with the use of radar, but its milliradian angular resolution translates to 100- m spatial resolution at 70-km distance. With sufficient power, radar can track a spacecraft as a whole object, but will not provide detail in the case of an accident, particularly for small debris in the onemeter range, which can only be achieved optically. It will be important to track the debris, which could disintegrate further into more debris, all the way to the ground. Such fragmentation could cause ballistic predictions, based on observations using high-resolution but narrow-field optics for only the first few seconds of the event, to be inaccurate. No optical imager architecture exists to satisfy NASA requirements. The HIT was developed for space vehicle tracking, in-flight inspection, and in the case of an accident, a detailed recording of the event. The system is a combination of five subsystems: (1) a roving fovea telescope with a wide 30 field of regard; (2) narrow, high-resolution fovea field optics; (3) a Coude optics system for telescope output beam stabilization; (4) a hyperspectral-mutispectral imaging assembly; and (5) image analysis software with effective adaptive spectral filtering algorithm for real-time contrast enhancement.
ACTS: from ATLAS software towards a common track reconstruction software
NASA Astrophysics Data System (ADS)
Gumpert, C.; Salzburger, A.; Kiehn, M.; Hrdinka, J.; Calace, N.; ATLAS Collaboration
2017-10-01
Reconstruction of charged particles’ trajectories is a crucial task for most particle physics experiments. The high instantaneous luminosity achieved at the LHC leads to a high number of proton-proton collisions per bunch crossing, which has put the track reconstruction software of the LHC experiments through a thorough test. Preserving track reconstruction performance under increasingly difficult experimental conditions, while keeping the usage of computational resources at a reasonable level, is an inherent problem for many HEP experiments. Exploiting concurrent algorithms and using multivariate techniques for track identification are the primary strategies to achieve that goal. Starting from current ATLAS software, the ACTS project aims to encapsulate track reconstruction software into a generic, framework- and experiment-independent software package. It provides a set of high-level algorithms and data structures for performing track reconstruction tasks as well as fast track simulation. The software is developed with special emphasis on thread-safety to support parallel execution of the code and data structures are optimised for vectorisation to speed up linear algebra operations. The implementation is agnostic to the details of the detection technologies and magnetic field configuration which makes it applicable to many different experiments.
77 FR 28193 - Excepted Service, Career and Career-Conditional Employment; and Pathways Programs
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-11
... advancement opportunities to Pathways Participants who are ``fast-tracked'' into desirable positions. The union's concern is misplaced. As an initial matter, the Pathways Participants are not being ``fast...-the-job experience that they otherwise would not be able to obtain. Indeed, rather than being ``fast...
1989-09-16
SWOTHR was conceived to be an organic asset capable of providing early detection and tracking of fast , surface-skimming threats, such as cruise missiles...distributed real-time processing and threat tracking system. Spe- cific project goals were to verify detection performance pree ctions for small, fast targets...means that enlarging the ground plane would have been a fruitless excercise in any event. B-6 5 i I U Table B-1 summarizes the calculated parameters of
Detlefsen, Ellen G
2004-01-01
The article describes an innovation in MLIS education for medical librarianship, with an introduction to the FastTrack, the distance education program at the University of Pittsburgh's library and information science school, together with an overview of a model program linking the biomedical library at Vanderbilt University with the School of Information Sciences in Pittsburgh. Admissions requirements and specific curriculum for the distance education master's degree are detailed in an FAQ format.
Studies on fast triggering and high precision tracking with Resistive Plate Chambers
NASA Astrophysics Data System (ADS)
Aielli, G.; Ball, R.; Bilki, B.; Chapman, J. W.; Cardarelli, R.; Dai, T.; Diehl, E.; Dubbert, J.; Ferretti, C.; Feng, H.; Francis, K.; Guan, L.; Han, L.; Hou, S.; Levin, D.; Li, B.; Liu, L.; Paolozzi, L.; Repond, J.; Roloff, J.; Santonico, R.; Song, H. Y.; Wang, X. L.; Wu, Y.; Xia, L.; Xu, L.; Zhao, T.; Zhao, Z.; Zhou, B.; Zhu, J.
2013-06-01
We report on studies of fast triggering and high precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV/c muon beam at CERN using glass RPCs with gas gaps of 1.15 mm and equipped with readout strips with 1.27 mm pitch. This is the first beam test of RPCs with fine-pitch readout strips that explores precision tracking and triggering capabilities. RPC signals were acquired with precision timing and charge integrating readout electronics at both ends of the strips. The time resolution was measured to be better than 600 ps and the average spatial resolution was found to be 220 μm using charge information and 287 μm only using signal arrival time information. The dual-ended readout allows the determination of the average and the difference of the signal arrival times. The average time was found to be independent of the incident particle position along the strip and is useful for triggering purposes. The time difference yielded a determination of the hit position with a precision of 7.5 mm along the strip. These results demonstrate the feasibility using RPCs for fast and high-resolution triggering and tracking.
Measuring Sound Speed in Gas Mixtures Using a Photoacoustic Generator
NASA Astrophysics Data System (ADS)
Suchenek, Mariusz; Borowski, Tomasz
2018-01-01
We present a new method which allows us to percentage distinction of gas composition with a fast response time. This system uses the speed of sound in a resonant cell along with temperature to determine the gas mixture composition. The gas mixtures contain two gases with an unknown combination. In our experiment, the acoustic waves were excited inside the acoustic longitudinal resonator with the use of a positive feedback. This feedback provides fast tracking of a resonance frequency of the cell and causes fast tracking changes in the speed of sound. The presented method corresponds to the theoretical description of this topic. Two gas mixtures—carbon dioxide and argon mixed with nitrogen—were tested.
A-Track: Detecting Moving Objects in FITS images
NASA Astrophysics Data System (ADS)
Atay, T.; Kaplan, M.; Kilic, Y.; Karapinar, N.
2017-04-01
A-Track is a fast, open-source, cross-platform pipeline for detecting moving objects (asteroids and comets) in sequential telescope images in FITS format. The moving objects are detected using a modified line detection algorithm.
Early development of an enterprise health data warehouse.
Househ, Mowafa Said; Al-Tuwaijri, Majid
2011-01-01
The purpose of this study is to describe early development challenges of an enterprise data warehouse within a Saudi Arabian academic healthcare facility. An action case research method was selected for this paper. The study took place between December 2009 and February 2010. Data collection included interviews, meeting observations, and meeting minutes. Early development challenges centered on the development of clear contracts with vendors; development of a clear project plan; a need to fast-track bureaucracy; and educate clinicians and staff about the project; and lack of data standardization.
ERIC Educational Resources Information Center
MARTINI, HARRY R.
BLACK AND WHITE FILMSTRIPS THAT REPRODUCED STILL PICTURES AND SOUND TRACK FROM EDUCATIONAL TELEVISION BROADCASTS WERE USED TO STUDY THE EFFECTIVENESS OF ETV REPRODUCTIONS IN AIDING POOR ACHIEVERS. THE SPECIFIC ADVANTAGE OF SUCH A REPRODUCTION WAS THAT IT COULD BE PACED TO THE LEARNING TEMPO OF THE STUDENTS RATHER THAN USING THE TOO-FAST PACE OF A…
International Space Station Alpha (ISSA) Integrated Traffic Model
NASA Technical Reports Server (NTRS)
Gates, R. E.
1995-01-01
The paper discusses the development process of the International Space Station Alpha (ISSA) Integrated Traffic Model which is a subsystem analyses tool utilized in the ISSA design analysis cycles. Fast-track prototyping of the detailed relationships between daily crew and station consumables, propellant needs, maintenance requirements and crew rotation via spread sheets provide adequate benchmarks to assess cargo vehicle design and performance characteristics.
Sethupathi, M; Blackwell, A
2009-03-01
We introduced a Nurse/Health Advisor-led fast-track service for treating patients diagnosed with chlamydia outside a genitourinary medicine setting and contacts of chlamydia/non-specific urethritis/cervicitis wherever diagnosed. Asymptomatic patients were treated without initial testing and asked to return for full screening at four to six weeks. We assessed the efficacy and safety of the system and need for follow-up after treatment. Case-notes of 226 patients (121 men and 105 women) were analysed, of whom 140 attended follow-up. With the exception of one case of gonorrhoea, no other serious sexually transmitted infection was detected. Twenty-seven (19.2%) patients were re-treated for either chlamydia (six patients, 4.4%) or non-specific genital infection or because of having unprotected intercourse with untreated or partially treated partners. We conclude that in our relatively low-risk population, our fast-track service is safe and effective. Test of cure for chlamydia seems essential because of the high percentage of patients requiring re-treatment.
Real-Time Robust Tracking for Motion Blur and Fast Motion via Correlation Filters.
Xu, Lingyun; Luo, Haibo; Hui, Bin; Chang, Zheng
2016-09-07
Visual tracking has extensive applications in intelligent monitoring and guidance systems. Among state-of-the-art tracking algorithms, Correlation Filter methods perform favorably in robustness, accuracy and speed. However, it also has shortcomings when dealing with pervasive target scale variation, motion blur and fast motion. In this paper we proposed a new real-time robust scheme based on Kernelized Correlation Filter (KCF) to significantly improve performance on motion blur and fast motion. By fusing KCF and STC trackers, our algorithm also solve the estimation of scale variation in many scenarios. We theoretically analyze the problem for CFs towards motions and utilize the point sharpness function of the target patch to evaluate the motion state of target. Then we set up an efficient scheme to handle the motion and scale variation without much time consuming. Our algorithm preserves the properties of KCF besides the ability to handle special scenarios. In the end extensive experimental results on benchmark of VOT datasets show our algorithm performs advantageously competed with the top-rank trackers.
Flying Qualities Design Requirements for Sidestick Controllers
1979-10-01
Harper vs wc - Fine Tracking 111 56. Cooper-Harper vs wc - Fine Tracking 111 57. Cooper-Harper ve wc - Landing 112 58. Cooper-Harper vs wc - Lending 112...c - Fine Tracking 119 62. Preference Rating vs wc - Fine Tracking 119 64. Preference Rating vs wc - Landing 120 65. Preference Rating vs w(c...a "fast airplane" to make up for the filtering effect of his arm and the stick. In fine tracking with a center stick the pilot will rest his arm
Fuel-conservative guidance system for powered-lift aircraft
NASA Technical Reports Server (NTRS)
Erzberger, H.; Mclean, J. D.
1979-01-01
A concept for automatic terminal area guidance, comprising two modes of operation, was developed and evaluated in flight tests. In the predictive mode, fuel efficient approach trajectories are synthesized in fast time. In the tracking mode, the synthesized trajectories are reconstructed and tracked automatically. An energy rate performance model derived from the lift, drag, and propulsion system characteristics of the aircraft is used in the synthesis algorithm. The method optimizes the trajectory for the initial aircraft position and wind and temperature profiles encountered during each landing approach. The design theory and the results of simulations and flight tests using the Augmentor Wing Jet STOL Research Aircraft are described.
Monocular Stereo Measurement Using High-Speed Catadioptric Tracking
Hu, Shaopeng; Matsumoto, Yuji; Takaki, Takeshi; Ishii, Idaku
2017-01-01
This paper presents a novel concept of real-time catadioptric stereo tracking using a single ultrafast mirror-drive pan-tilt active vision system that can simultaneously switch between hundreds of different views in a second. By accelerating video-shooting, computation, and actuation at the millisecond-granularity level for time-division multithreaded processing in ultrafast gaze control, the active vision system can function virtually as two or more tracking cameras with different views. It enables a single active vision system to act as virtual left and right pan-tilt cameras that can simultaneously shoot a pair of stereo images for the same object to be observed at arbitrary viewpoints by switching the direction of the mirrors of the active vision system frame by frame. We developed a monocular galvano-mirror-based stereo tracking system that can switch between 500 different views in a second, and it functions as a catadioptric active stereo with left and right pan-tilt tracking cameras that can virtually capture 8-bit color 512×512 images each operating at 250 fps to mechanically track a fast-moving object with a sufficient parallax for accurate 3D measurement. Several tracking experiments for moving objects in 3D space are described to demonstrate the performance of our monocular stereo tracking system. PMID:28792483
A sun-tracking environmental chamber for the outdoor quantification of CPV modules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faiman, David, E-mail: faiman@bgu.ac.il; Melnichak, Vladimir, E-mail: faiman@bgu.ac.il; Bokobza, Dov, E-mail: faiman@bgu.ac.il
2014-09-26
The paper describes a sun-tracking environmental chamber and its associated fast electronics, devised for the accurate outdoor characterization of CPV cells, receivers, mono-modules, and modules. Some typical measurement results are presented.
Active-passive hybrid piezoelectric actuators for high-precision hard disk drive servo systems
NASA Astrophysics Data System (ADS)
Chan, Kwong Wah; Liao, Wei-Hsin
2006-03-01
Positioning precision is crucial to today's increasingly high-speed, high-capacity, high data density, and miniaturized hard disk drives (HDDs). The demand for higher bandwidth servo systems that can quickly and precisely position the read/write head on a high track density becomes more pressing. Recently, the idea of applying dual-stage actuators to track servo systems has been studied. The push-pull piezoelectric actuated devices have been developed as micro actuators for fine and fast positioning, while the voice coil motor functions as a large but coarse seeking. However, the current dual-stage actuator design uses piezoelectric patches only without passive damping. In this paper, we propose a dual-stage servo system using enhanced active-passive hybrid piezoelectric actuators. The proposed actuators will improve the existing dual-stage actuators for higher precision and shock resistance, due to the incorporation of passive damping in the design. We aim to develop this hybrid servo system not only to increase speed of track seeking but also to improve precision of track following servos in HDDs. New piezoelectrically actuated suspensions with passive damping have been designed and fabricated. In order to evaluate positioning and track following performances for the dual-stage track servo systems, experimental efforts are carried out to implement the synthesized active-passive suspension structure with enhanced piezoelectric actuators using a composite nonlinear feedback controller.
Laser Spot Tracking Based on Modified Circular Hough Transform and Motion Pattern Analysis
Krstinić, Damir; Skelin, Ana Kuzmanić; Milatić, Ivan
2014-01-01
Laser pointers are one of the most widely used interactive and pointing devices in different human-computer interaction systems. Existing approaches to vision-based laser spot tracking are designed for controlled indoor environments with the main assumption that the laser spot is very bright, if not the brightest, spot in images. In this work, we are interested in developing a method for an outdoor, open-space environment, which could be implemented on embedded devices with limited computational resources. Under these circumstances, none of the assumptions of existing methods for laser spot tracking can be applied, yet a novel and fast method with robust performance is required. Throughout the paper, we will propose and evaluate an efficient method based on modified circular Hough transform and Lucas–Kanade motion analysis. Encouraging results on a representative dataset demonstrate the potential of our method in an uncontrolled outdoor environment, while achieving maximal accuracy indoors. Our dataset and ground truth data are made publicly available for further development. PMID:25350502
Laser spot tracking based on modified circular Hough transform and motion pattern analysis.
Krstinić, Damir; Skelin, Ana Kuzmanić; Milatić, Ivan
2014-10-27
Laser pointers are one of the most widely used interactive and pointing devices in different human-computer interaction systems. Existing approaches to vision-based laser spot tracking are designed for controlled indoor environments with the main assumption that the laser spot is very bright, if not the brightest, spot in images. In this work, we are interested in developing a method for an outdoor, open-space environment, which could be implemented on embedded devices with limited computational resources. Under these circumstances, none of the assumptions of existing methods for laser spot tracking can be applied, yet a novel and fast method with robust performance is required. Throughout the paper, we will propose and evaluate an efficient method based on modified circular Hough transform and Lucas-Kanade motion analysis. Encouraging results on a representative dataset demonstrate the potential of our method in an uncontrolled outdoor environment, while achieving maximal accuracy indoors. Our dataset and ground truth data are made publicly available for further development.
Prades, J; Espinàs, J A; Font, R; Argimon, J M; Borràs, J M
2011-01-01
Background: The Cancer Fast-track Programme's aim was to reduce the time that elapsed between well-founded suspicion of breast, colorectal and lung cancer and the start of initial treatment in Catalonia (Spain). We sought to analyse its implementation and overall effectiveness. Methods: A quantitative analysis of the programme was performed using data generated by the hospitals on the basis of seven fast-track monitoring indicators for the period 2006–2009. In addition, we conducted a qualitative study, based on 83 semistructured interviews with primary and specialised health professionals and health administrators, to obtain their perception of the programme's implementation. Results: About half of all new patients with breast, lung or colorectal cancer were diagnosed via the fast track, though the cancer detection rate declined across the period. Mean time from detection of suspected cancer in primary care to start of initial treatment was 32 days for breast, 30 for colorectal and 37 for lung cancer (2009). Professionals associated with the implementation of the programme showed that general practitioners faced with suspicion of cancer had changed their conduct with the aim of preventing lags. Furthermore, hospitals were found to have pursued three specific implementation strategies (top-down, consensus-based and participatory), which made for the cohesion and sustainability of the circuits. Conclusion: The programme has contributed to speeding up diagnostic assessment and treatment of patients with suspicion of cancer, and to clarifying the patient pathway between primary and specialised care. PMID:21829194
Gastinger, Ingo; Meyer, Frank; Lembcke, Thomas; Schmidt, Uwe; Ptok, Henry; Lippert, Hans
2012-08-01
The aim of the study was to determine statistically significant factors with an impact on the early postoperative surgical outcome. The influence of applied fast-track components on surgical results and early postoperative outcome in 143 consecutive Kausch-Whipple procedure patients was evaluated in a single-center retrospective analysis of a prospective collection of patient-associated pre-, peri- and postoperative data from 1997-2006. The in-hospital mortality rate was 2.8% (n=4). Fast-track measures were shown to have no effect on the morbidity rate in the multi-variate analysis. Over the study period, a decrease of intraoperative infusion volume from 14.2 mL/kg body weight/h in the first year to 10.7 mL/kg body weight/h in the last year was accompanied by an increase in patients requiring intraoperative catecholamines, up from 17% to 95%. The administration of ropivacain/sufentanil via thoracic peri-dural catheter injection initiated in 2000 and now considered the leading analgesic method, was used in 95% of the cases in 2006. Early extubation rate rose from 16.6% to 57.9%. Fast-track aspects in the perioperative management have become more important in several surgical procedure even in those with a greater invasiveness such as Kausch-Whipple. However, such techniques used in peri-operative management of Kausch-Whipple pancreatic-head resections had no impact on the morbidity rate. In addition, the low in-hospital mortality rate was particularly attributed to surgical competence.
Imamoglu, Nevrez; Dorronzoro, Enrique; Wei, Zhixuan; Shi, Huangjun; Sekine, Masashi; González, José; Gu, Dongyun; Chen, Weidong; Yu, Wenwei
2014-01-01
Our research is focused on the development of an at-home health care biomonitoring mobile robot for the people in demand. Main task of the robot is to detect and track a designated subject while recognizing his/her activity for analysis and to provide warning in an emergency. In order to push forward the system towards its real application, in this study, we tested the robustness of the robot system with several major environment changes, control parameter changes, and subject variation. First, an improved color tracker was analyzed to find out the limitations and constraints of the robot visual tracking considering the suitable illumination values and tracking distance intervals. Then, regarding subject safety and continuous robot based subject tracking, various control parameters were tested on different layouts in a room. Finally, the main objective of the system is to find out walking activities for different patterns for further analysis. Therefore, we proposed a fast, simple, and person specific new activity recognition model by making full use of localization information, which is robust to partial occlusion. The proposed activity recognition algorithm was tested on different walking patterns with different subjects, and the results showed high recognition accuracy.
Imamoglu, Nevrez; Dorronzoro, Enrique; Wei, Zhixuan; Shi, Huangjun; González, José; Gu, Dongyun; Yu, Wenwei
2014-01-01
Our research is focused on the development of an at-home health care biomonitoring mobile robot for the people in demand. Main task of the robot is to detect and track a designated subject while recognizing his/her activity for analysis and to provide warning in an emergency. In order to push forward the system towards its real application, in this study, we tested the robustness of the robot system with several major environment changes, control parameter changes, and subject variation. First, an improved color tracker was analyzed to find out the limitations and constraints of the robot visual tracking considering the suitable illumination values and tracking distance intervals. Then, regarding subject safety and continuous robot based subject tracking, various control parameters were tested on different layouts in a room. Finally, the main objective of the system is to find out walking activities for different patterns for further analysis. Therefore, we proposed a fast, simple, and person specific new activity recognition model by making full use of localization information, which is robust to partial occlusion. The proposed activity recognition algorithm was tested on different walking patterns with different subjects, and the results showed high recognition accuracy. PMID:25587560
Three-dimensional particle tracking velocimetry using dynamic vision sensors
NASA Astrophysics Data System (ADS)
Borer, D.; Delbruck, T.; Rösgen, T.
2017-12-01
A fast-flow visualization method is presented based on tracking neutrally buoyant soap bubbles with a set of neuromorphic cameras. The "dynamic vision sensors" register only the changes in brightness with very low latency, capturing fast processes at a low data rate. The data consist of a stream of asynchronous events, each encoding the corresponding pixel position, the time instant of the event and the sign of the change in logarithmic intensity. The work uses three such synchronized cameras to perform 3D particle tracking in a medium sized wind tunnel. The data analysis relies on Kalman filters to associate the asynchronous events with individual tracers and to reconstruct the three-dimensional path and velocity based on calibrated sensor information.
[Morbidity and hospital cost reduction in cardiac surgery using a presurgery ambulatory strategy].
Ávila-Vanzzini, Nydia; Kuri-Alfaro, Jorge; Rodríguez-Chávez, Laura Leticia; Meléndez-Ramírez, Gabriela; Trevethan-Cravioto, Sergio; Quiroz-Martínez, Alejandro; Herrera-Bello, Héctor; Herrera-Alarcón, Valentín; Martínez-Hernández, Humberto; Martínez-Ríos, Marco Antonio
2010-01-01
In our hospital, the patients that need an elective cardiac surgery are admitted through the admission department on the basis of a waiting list. Since 1999, a fast track to hospitalization program has existed in the National Institute of Cardiology Ignacio Chavez for patients with low surgical risk. Later, in 2004, this program was extended to patients to moderate risk, based on rules accepted worldwide, and our own experience. 1) To compare two ways of admission that are used currently: fast track to hospitalization, against admission department waiting list. We compared major events: death or events that increased the hospital stay by more than 14 days (infections, alterations of rhythm and conduction, reoperations and others), 2) To compare the days of hospitalization and money spent by the hospital. We conformed 2 groups of 347 patients. The admission department waiting list group was admitted before doing their preoperative studies, which is the customary form for hospitalization by our admissions department, while the group of fast track to hospitalization was obligated to have their laboratory exams complete and any other diseases resolved or controlled previously. The monetary cost per patient for the hospital was calculated based on the patient's socioeconomic classification. Student t test was conduncted on independent samples and numerical variables, and Chi square for categorical variables. We considered a p <0.05 to be statistically significant. In average in both groups, 75% underwent valve operation and 25% underwent congenital heart disease repair, 49% were women, age 47 15 years. The comparison between the groups fast track to hospitalization and admission department waiting list group were: Mortality: 4.3% vs. 5.8% (p=0.38). Major events that needed a hospital stay of more than 14 days: 73 vs. 97 cases respectively (p = 0.032). Infections: 22 vs. 29 (p = 0.14). Mediastinitis: 2 vs. 9 respectively (p = 0.033). In-hospital stay: were 11 days vs. 20 days (p = 0.0001), the biggest difference was found in the pre-surgical time: 2 vs. 9 days respectively (p = 0.0001). The postoperative morbidity in general was lower in fast track to hospitalization group, and the mediastinitis showed a decrease with statistical significance. The time interval between hospital admission an operation in fast track to hospitalization group was significantly shorter. We believe that the decrease in the exposure time to nosocomial pathogens present in the hospital environment was directly related to the low number of mediastinitis. Finally, the decrease in time of hospital stay represented a 32% monetary savings for the hospital.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutcliffe, G. D.; Milanese, L. M.; Orozco, D.
CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint ofmore » the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.« less
An Adaptive 6-DOF Tracking Method by Hybrid Sensing for Ultrasonic Endoscopes
Du, Chengyang; Chen, Xiaodong; Wang, Yi; Li, Junwei; Yu, Daoyin
2014-01-01
In this paper, a novel hybrid sensing method for tracking an ultrasonic endoscope within the gastrointestinal (GI) track is presented, and the prototype of the tracking system is also developed. We implement 6-DOF localization by sensing integration and information fusion. On the hardware level, a tri-axis gyroscope and accelerometer, and a magnetic angular rate and gravity (MARG) sensor array are attached at the end of endoscopes, and three symmetric cylindrical coils are placed around patients' abdomens. On the algorithm level, an adaptive fast quaternion convergence (AFQC) algorithm is introduced to determine the orientation by fusing inertial/magnetic measurements, in which the effects of magnetic disturbance and acceleration are estimated to gain an adaptive convergence output. A simplified electro-magnetic tracking (SEMT) algorithm for dimensional position is also implemented, which can easily integrate the AFQC's results and magnetic measurements. Subsequently, the average position error is under 0.3 cm by reasonable setting, and the average orientation error is 1° without noise. If magnetic disturbance or acceleration exists, the average orientation error can be controlled to less than 3.5°. PMID:24915179
Malinowski, K; Skladnik-Sadowska, E; Sadowski, M J; Szydlowski, A; Czaus, K; Kwiatkowski, R; Zaloga, D; Paduch, M; Zielinska, E
2015-01-01
The paper concerns fast protons and neutrons from D-D fusion reactions in a Plasma-Focus-1000U facility. Measurements were performed with nuclear-track detectors arranged in "sandwiches" of an Al-foil and two PM-355 detectors separated by a polyethylene-plate. The Al-foil eliminated all primary deuterons, but was penetrable for fast fusion protons. The foil and first PM-355 detector were penetrable for fast neutrons, which were converted into recoil-protons in the polyethylene and recorded in the second PM-355 detector. The "sandwiches" were irradiated by discharges of comparable neutron-yields. Analyses of etched tracks and computer simulations of the fusion-products behavior in the detectors were performed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malinowski, K., E-mail: karol.malinowski@ncbj.gov.pl; Sadowski, M. J.; Szydlowski, A.
2015-01-15
The paper concerns fast protons and neutrons from D-D fusion reactions in a Plasma-Focus-1000U facility. Measurements were performed with nuclear-track detectors arranged in “sandwiches” of an Al-foil and two PM-355 detectors separated by a polyethylene-plate. The Al-foil eliminated all primary deuterons, but was penetrable for fast fusion protons. The foil and first PM-355 detector were penetrable for fast neutrons, which were converted into recoil-protons in the polyethylene and recorded in the second PM-355 detector. The “sandwiches” were irradiated by discharges of comparable neutron-yields. Analyses of etched tracks and computer simulations of the fusion-products behavior in the detectors were performed.
Design of a tracking device for on-line dose monitoring in hadrontherapy
NASA Astrophysics Data System (ADS)
Battistoni, G.; Collamati, F.; De Lucia, E.; Faccini, R.; Marafini, M.; Mattei, I.; Muraro, S.; Paramatti, R.; Patera, V.; Pinci, D.; Rucinski, A.; Russomando, A.; Sarti, A.; Sciubba, A.; Solfaroli Camillocci, E.; Toppi, M.; Traini, G.; Voena, C.
2017-02-01
Hadrontherapy is a technique for cancer treatment that exploits ion beams (mostly protons and carbons). A critical issue is the accuracy that is achievable when monitoring the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a tracking device, developed in the framework of the INSIDE project [1], capable of monitoring in real time the longitudinal profile of the dose delivered in the patient. This is possible by detecting the secondary particles produced by the interaction of the beam in the tissues. The position of the Bragg peak can be correlated to the charged particles emission point distribution measurement. The tracking device will be able to provide a fast response on the dose pattern by tracking the secondary charged fragments. The tracks are detected using 6 planes of scintillating fibers, providing the 3D coordinates of the track intersection with each plane. The fibers planes are followed by a plastic scintillator and by a small calorimeter built with a pixelated Lutetium Fine Silicate (LFS) crystal. A complete detector simulation, followed by the event reconstruction, has been performed to determine the achievable monitoring spatial resolution.
Astrometry with A-Track Using Gaia DR1 Catalogue
NASA Astrophysics Data System (ADS)
Kılıç, Yücel; Erece, Orhan; Kaplan, Murat
2018-04-01
In this work, we built all sky index files from Gaia DR1 catalogue for the high-precision astrometric field solution and the precise WCS coordinates of the moving objects. For this, we used build-astrometry-index program as a part of astrometry.net code suit. Additionally, we added astrometry.net's WCS solution tool to our previously developed software which is a fast and robust pipeline for detecting moving objects such as asteroids and comets in sequential FITS images, called A-Track. Moreover, MPC module was added to A-Track. This module is linked to an asteroid database to name the found objects and prepare the MPC file to report the results. After these innovations, we tested a new version of the A-Track code on photometrical data taken by the SI-1100 CCD with 1-meter telescope at TÜBİTAK National Observatory, Antalya. The pipeline can be used to analyse large data archives or daily sequential data. The code is hosted on GitHub under the GNU GPL v3 license.
The Flex Track: Flexible Partitioning between Low- and High-Acuity Areas of an Emergency Department
Laker, Lauren F.; Froehle, Craig M.; Lindsell, Christopher J.; Ward, Michael J.
2014-01-01
Study Objective EDs with both low- and high-acuity treatment areas often have fixed allocation of resources, regardless of demand. We demonstrate the utility of discrete-event simulation to evaluate flexible partitioning between low- and high-acuity ED areas to identify the best operational strategy for subsequent implementation. Methods A discrete-event simulation was used to model patient flow through a 50-bed, urban, teaching ED that handles 85,000 patient visits annually. The ED has historically allocated ten beds to a Fast Track for low-acuity patients. We estimated the effect of a Flex Track policy, which involved switching up to five of these Fast Track beds to serving both low- and high-acuity patients, on patient waiting times. When the high-acuity beds were not at capacity, low-acuity patients were given priority access to flexible beds. Otherwise, high-acuity patients were given priority access to flexible beds. Wait times were estimated for patients by disposition and emergency severity index (ESI) score. Results A Flex Track policy using three flexible beds produced the lowest mean patient waiting of 30.9 (95% CI 30.6–31.2) minutes. The typical Fast Track approach of rigidly separating high- and low–acuity beds produced a mean patient wait time of 40.6 (95% CI 40.2–50.0) minutes, 31% higher than the three-bed Flex Track. A completely flexible ED, where all beds can accommodate any patient, produced mean wait times of 35.1 (95% CI 34.8–35.4) minutes. The results from the three-bed Flex Track scenario were robust, performing well across a range of scenarios involving higher and lower patient volumes and care durations. Conclusion Using discrete-event simulation, we have shown that adding some flexibility into bed allocation between low- and high-acuity can provide substantial reductions in overall patient waiting and a more efficient ED. PMID:24954578
Nonequilibrium Nonideal Nanoplasma Generated by a Fast Single Ion in Condensed Matter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faenov, A. Ya.; Kansai Photon Science Institut, Japan Atomic Energy Agency; Lankin, A. V.
A plasma model of relaxation of a medium in heavy ion tracks in condensed matter is proposed. The model is based on three assumptions: the Maxwell distribution of plasma electrons, localization of plasma inside the track nanochannel and constant values of the plasma electron density and temperature during the X-ray irradiation. It is demonstrated that the plasma relaxation model adequately describes the X-ray spectra observed upon interaction of a fast ion with condensed target. Preassumptions of plasma relaxation model are validated by the molecular dynamics modeling and simulation.
ERIC Educational Resources Information Center
Bermingham, Desmond
2011-01-01
The Education for All Fast Track Initiative (FTI) was launched by the World Bank in 2002 as a global initiative to help low income countries accelerate progress towards the MDG target of universal primary education by 2015. Over the past decade, the FTI has expanded to become one of the most important initiatives to emerge out of the Dakar World…
Aerospace plane guidance using geometric control theory
NASA Technical Reports Server (NTRS)
Van Buren, Mark A.; Mease, Kenneth D.
1990-01-01
A reduced-order method employing decomposition, based on time-scale separation, of the 4-D state space in a 2-D slow manifold and a family of 2-D fast manifolds is shown to provide an excellent approximation to the full-order minimum-fuel ascent trajectory. Near-optimal guidance is obtained by tracking the reduced-order trajectory. The tracking problem is solved as regulation problems on the family of fast manifolds, using the exact linearization methodology from nonlinear geometric control theory. The validity of the overall guidance approach is indicated by simulation.
Exhausting Attentional Tracking Resources with a Single Fast-Moving Object
ERIC Educational Resources Information Center
Holcombe, Alex O.; Chen, Wei-Ying
2012-01-01
Driving on a busy road, eluding a group of predators, or playing a team sport involves keeping track of multiple moving objects. In typical laboratory tasks, the number of visual targets that humans can track is about four. Three types of theories have been advanced to explain this limit. The fixed-limit theory posits a set number of attentional…
U.S. masters track participation reveals a stable sex difference in competitiveness.
Deaner, Robert O; Addona, Vittorio; Mead, Michael P
2014-10-06
It is well established that men are more likely than women to engage in direct competition, but it is unclear if this reflects social structural conditions or evolved predispositions. These hypotheses can be addressed by quantifying competitiveness in sports and testing if the sex difference is decreasing over time in the U.S., a society where social roles have converged. Study 1 assessed participation and the occurrence of relatively fast performances by masters runners (40-74 years old) at recent road races and track meets. Fast performances occurred over 20 times more often at track meets than at road races. Women comprised 55% of finishers at roads races but only 15-28% of finishers at track meets. Thus, the sex difference in masters track participation can serve as a measure of the sex difference in competitiveness. Study 2 used data from national championship meets and yearly rankings lists to test whether the sex difference in masters track participation decreased from 1988-2012. The sex difference decreased overall, but there was no evidence of change since the late 1990s. Therefore, the sex difference in the willingness to engage in direct sports competition appears to reflect both social structural conditions and evolved predispositions.
International Space Station Alpha (ISSA) Integrated Traffic Model
NASA Technical Reports Server (NTRS)
Gates, Robert E.
1994-01-01
The paper discusses the development process of the International Space Station Alpha (ISSA) Integrated Traffic Model which is a subsystem analyses tool utilized in the ISSA design analysis cycles. Fast-track prototyping of the detailed relationships between daily crew and station consumables, propellant needs, maintenance requirements, and crew rotation via spread sheets provides adequate bench marks to assess cargo vehicle design and performance characteristics.
ERIC Educational Resources Information Center
Okebukola, Foluso O.; Adegbite, Hassan H.; Owolabi, Tunde
2013-01-01
The study focuses on the eradication and reversal of the spread of HIV/AIDS (human immune virus/acquired immune deficiency syndrome) as one of the main thrusts of Africa's 21st Century Development Goals. It investigates the significant role which language and education can play in fast tracking the attainment of this goal using a three-pronged…
ACC Effectiveness Review, 1999-2002.
ERIC Educational Resources Information Center
Wallace, Roslyn, Ed.
2002-01-01
These newsletters on Institutional Effectiveness (IE) at Austin Community College (ACC) in Texas include the following articles: (1) "The 'Fast Track'...Students Say It Works!" (2) "Are Students Successfully Completing Distance Learning Courses at ACC?" (3) "Tracking Transfers"; (4) "Math Pilot: Study Skills…
Observed ocean waves by tropical cyclones
NASA Astrophysics Data System (ADS)
Zhang, Lin; Oey, Leo
2017-04-01
Ocean waves produced by tropical cyclones (TC) modify air-sea fluxes which in turn are crucial to the storms' intensity and development, yet they are poorly understood. Here we use 24 years (1992-2015) of observed waves, winds and TC-track information to stratify storm-centered composite maps of waves and winds according to TC intensities and translation speeds (Uh). While the wind field is rightward-asymmetric independent of Uh, the wave field is rightward-symmetric in concert with the wind for slow-translating TCs (Uh ≤ 3 m s-1), but right-rear asymmetric with strongest waves in the 4th quadrant for medium to fast-translating TCs (3 < Uh ≤ 7 m s-1), especially for the very fast storms (Uh > 7 m s-1), all independent of TC-intensity. The dominance of the right-rear asymmetry for fast-translating TCs appears to be related to the development of cross swells as the storms move faster, but further research using models are needed to understand the physical mechanisms.
Development of real-time motion capture system for 3D on-line games linked with virtual character
NASA Astrophysics Data System (ADS)
Kim, Jong Hyeong; Ryu, Young Kee; Cho, Hyung Suck
2004-10-01
Motion tracking method is being issued as essential part of the entertainment, medical, sports, education and industry with the development of 3-D virtual reality. Virtual human character in the digital animation and game application has been controlled by interfacing devices; mouse, joysticks, midi-slider, and so on. Those devices could not enable virtual human character to move smoothly and naturally. Furthermore, high-end human motion capture systems in commercial market are expensive and complicated. In this paper, we proposed a practical and fast motion capturing system consisting of optic sensors, and linked the data with 3-D game character with real time. The prototype experiment setup is successfully applied to a boxing game which requires very fast movement of human character.
Active disturbance rejection controller of fine tracking system for free space optical communication
NASA Astrophysics Data System (ADS)
Cui, Ning; Liu, Yang; Chen, Xinglin; Wang, Yan
2013-08-01
Free space optical communication is one of the best approaches in future communications. Laser beam's acquisition, pointing and tracking are crucial technologies of free space optical communication. Fine tracking system is important component of APT (acquisition, pointing and tracking) system. It cooperates with the coarse pointing system in executing the APT mission. Satellite platform vibration and disturbance, which reduce received optical power, increase bit error rate and affect seriously the natural performance of laser communication. For the characteristic of satellite platform, an active disturbance rejection controller was designed to reduce the vibration and disturbance. There are three major contributions in the paper. Firstly, the effects of vibration on the inter satellite optical communications were analyzed, and the reasons and characters of vibration of the satellite platform were summarized. The amplitude-frequency response of a filter was designed according to the power spectral density of platform vibration of SILEX (Semiconductor Inter-satellite Laser Experiment), and then the signals of platform vibration were generated by filtering white Gaussian noise using the filter. Secondly, the fast steering mirror is a key component of the fine tracking system for optical communication. The mechanical design and model analysis was made to the tip/tilt mirror driven by the piezoelectric actuator and transmitted by the flexure hinge. The transfer function of the fast steering mirror, camera, D/A data acquisition card was established, and the theory model of transfer function of this system was further obtained. Finally, an active disturbance rejection control method is developed, multiple parallel extended state observers were designed for estimation of unknown dynamics and external disturbance, and the estimated states were used for nonlinear feedback control and compensation to improve system performance. The simulation results show that the designed controller not only accurately estimates and compensates the disturbances, but also realizes the robustness to estimation of unknown dynamics. The controller can satisfy the requirement of fine tracking accuracy for free space optical communication system.
Use of a genetic algorithm for the analysis of eye movements from the linear vestibulo-ocular reflex
NASA Technical Reports Server (NTRS)
Shelhamer, M.
2001-01-01
It is common in vestibular and oculomotor testing to use a single-frequency (sine) or combination of frequencies [sum-of-sines (SOS)] stimulus for head or target motion. The resulting eye movements typically contain a smooth tracking component, which follows the stimulus, in which are interspersed rapid eye movements (saccades or fast phases). The parameters of the smooth tracking--the amplitude and phase of each component frequency--are of interest; many methods have been devised that attempt to identify and remove the fast eye movements from the smooth. We describe a new approach to this problem, tailored to both single-frequency and sum-of-sines stimulation of the human linear vestibulo-ocular reflex. An approximate derivative is used to identify fast movements, which are then omitted from further analysis. The remaining points form a series of smooth tracking segments. A genetic algorithm is used to fit these segments together to form a smooth (but disconnected) wave form, by iteratively removing biases due to the missing fast phases. A genetic algorithm is an iterative optimization procedure; it provides a basis for extending this approach to more complex stimulus-response situations. In the SOS case, the genetic algorithm estimates the amplitude and phase values of the component frequencies as well as removing biases.
Numerical simulation of film-cooled ablative rocket nozzles
NASA Technical Reports Server (NTRS)
Landrum, D. B.; Beard, R. M.
1996-01-01
The objective of this research effort was to evaluate the impact of incorporating an additional cooling port downstream between the injector and nozzle throat in the NASA Fast Track chamber. A numerical model of the chamber was developed for the analysis. The analysis did not model ablation but instead correlated the initial ablation rate with the initial nozzle wall temperature distribution. The results of this study provide guidance in the development of a potentially lighter, second generation ablative rocket nozzle which maintains desired performance levels.
Tracking a convoy of multiple targets using acoustic sensor data
NASA Astrophysics Data System (ADS)
Damarla, T. R.
2003-08-01
In this paper we present an algorithm to track a convoy of several targets in a scene using acoustic sensor array data. The tracking algorithm is based on template of the direction of arrival (DOA) angles for the leading target. Often the first target is the closest target to the sensor array and hence the loudest with good signal to noise ratio. Several steps were used to generate a template of the DOA angle for the leading target, namely, (a) the angle at the present instant should be close to the angle at the previous instant and (b) the angle at the present instant should be within error bounds of the predicted value based on the previous values. Once the template of the DOA angles of the leading target is developed, it is used to predict the DOA angle tracks of the remaining targets. In order to generate the tracks for the remaining targets, a track is established if the angles correspond to the initial track values of the first target. Second the time delay between the first track and the remaining tracks are estimated at the highest correlation points between the first track and the remaining tracks. As the vehicles move at different speeds the tracks either compress or expand depending on whether a target is moving fast or slow compared to the first target. The expansion and compression ratios are estimated and used to estimate the predicted DOA angle values of the remaining targets. Based on these predicted DOA angles of the remaining targets the DOA angles obtained from the MVDR or Incoherent MUSIC will be appropriately assigned to proper tracks. Several other rules were developed to avoid mixing the tracks. The algorithm is tested on data collected at Aberdeen Proving Ground with a convoy of 3, 4 and 5 vehicles. Some of the vehicles are tracked and some are wheeled vehicles. The tracking algorithm results are found to be good. The results will be presented at the conference and in the paper.
Waheed, Yasir; Waheed, Hasnain
2017-05-12
In last fifteen years remarkable success in the fight against human immunodeficiency virus (HIV) is achieved globally. The number of HIV infections has decreased and the number of people on antiretroviral therapy is increased. This all is possible by strong political commitments and heavy investments in the fight against HIV. Pakistan is among few Asian countries in which HIV cases are increasing year by year since 1990. There are 94000 cases of HIV in Pakistan and only 14000 are registered with government. The main source of HIV infection in Pakistan is the use of contaminated injection equipment among people who inject drugs (PWID). The overall prevalence of HIV among PWID in Pakistan is 27.2%. There are five cities in Pakistan in which HIV prevalence is above 40% in PWIDs. In June 2016, United Nations political declaration on acquired immune deficiency syndrome (AIDS) provided a global mandate to fast-track the AIDS response over the next five years to achieve the targets in Sustainable Development Goals. To achieve the targets in fast-track AIDS response, the global leaders showed strong commitments to invest $ 26 billion per year by 2020. Pakistan needs to speed up its HIV control program. There is a dire need to locate all HIV positive people and enroll them in the treatment program. Pakistan also needs to calculate exact number of people living with HIV, increase HIV treatment centers and increase HIV awareness. Recently, Global Fund invested handsome money in the fight against HIV. Let's hope the country will have effective HIV control strategy to achieve the HIV elimination target by 2030.
Peng, Lele; Zheng, Shubin; Xu, Wei; Xin, Li
2018-04-01
This article presents the data on photovoltaic (PV) system used different perturb and observe (P&O) methods under fast multi-changing solar irradiances. The mathematical modeling of the PV system and tangent error P&O method was discussed in our previous study entitled "A novel tangent error maximum power point tracking algorithm for photovoltaic system under fast multi-changing solar irradiances" by Peng et al. (2018) [1]. The data provided in this paper can be used directly without having to spend weeks to simulate the output performance. In addition, it is easy to apply the results for comparison with other algorithms (Kollimalla et al., 2014; Belkaid et al., 2016; Chenchen et al., 2015; Jubaer and Zainal, 2015) [2,3,4,5], and develop a new method for practical application.
NASA Technical Reports Server (NTRS)
Toelle, Ronald (Compiler)
1995-01-01
A launch vehicle concept to deliver 20,000 lb of payload to a 100-nmi orbit has been defined. A new liquid oxygen/kerosene booster powered by an RD-180 engine was designed while using a slightly modified Centaur upper stage. The design, development, and test program met the imposed 40-mo schedule by elimination of major structural testing by increased factors of safety and concurrent engineering concepts. A growth path to attain 65,000 lb of payload is developed.
Velocity-free attitude coordinated tracking control for spacecraft formation flying.
Hu, Qinglei; Zhang, Jian; Zhang, Youmin
2018-02-01
This article investigates the velocity-free attitude coordinated tracking control scheme for a group of spacecraft with the assumption that the angular velocities of the formation members are not available in control feedback. Initially, an angular velocity observer is constructed based on each individual's attitude quarternion. Then, the distributed attitude coordinated control law is designed by using the observed states, in which adaptive control method is adopted to handle the external disturbances. Stability of the overall closed-loop system is analyzed theoretically, which shows the system trajectory converges to a small set around origin with fast convergence rate. Numerical simulations are performed to demonstrate fast convergence and improved tracking performance of the proposed control strategy. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Designing Tracking Software for Image-Guided Surgery Applications: IGSTK Experience
Enquobahrie, Andinet; Gobbi, David; Turek, Matt; Cheng, Patrick; Yaniv, Ziv; Lindseth, Frank; Cleary, Kevin
2009-01-01
Objective Many image-guided surgery applications require tracking devices as part of their core functionality. The Image-Guided Surgery Toolkit (IGSTK) was designed and developed to interface tracking devices with software applications incorporating medical images. Methods IGSTK was designed as an open source C++ library that provides the basic components needed for fast prototyping and development of image-guided surgery applications. This library follows a component-based architecture with several components designed for specific sets of image-guided surgery functions. At the core of the toolkit is the tracker component that handles communication between a control computer and navigation device to gather pose measurements of surgical instruments present in the surgical scene. The representations of the tracked instruments are superimposed on anatomical images to provide visual feedback to the clinician during surgical procedures. Results The initial version of the IGSTK toolkit has been released in the public domain and several trackers are supported. The toolkit and related information are available at www.igstk.org. Conclusion With the increased popularity of minimally invasive procedures in health care, several tracking devices have been developed for medical applications. Designing and implementing high-quality and safe software to handle these different types of trackers in a common framework is a challenging task. It requires establishing key software design principles that emphasize abstraction, extensibility, reusability, fault-tolerance, and portability. IGSTK is an open source library that satisfies these needs for the image-guided surgery community. PMID:20037671
Fuel-conservative guidance system for powered-lift aircraft
NASA Technical Reports Server (NTRS)
Erzberger, H.; Mclean, J. D.
1979-01-01
A concept for automatic terminal-area guidance, comprising two modes of operation, has been developed and evaluated in flight tests. In the first or predictive mode, fuel-efficient approach trajectories are synthesized in fast time. In the second or tracking mode, the synthesized trajectories are reconstructed and tracked automatically. An energy rate performance model derived from the lift, drag, and propulsion-system characteristics of the aircraft is used in the synthesis algorithm. The method optimizes the trajectory for the initial aircraft position and wind and temperature profiles encountered during each landing approach. The paper describes the design theory and discusses the results of simulations and flight tests using the Augmentor Wing Jet STOL Research Aircraft.
Segmentation of Nerve Bundles and Ganglia in Spine MRI Using Particle Filters
Dalca, Adrian; Danagoulian, Giovanna; Kikinis, Ron; Schmidt, Ehud; Golland, Polina
2011-01-01
Automatic segmentation of spinal nerve bundles that originate within the dural sac and exit the spinal canal is important for diagnosis and surgical planning. The variability in intensity, contrast, shape and direction of nerves seen in high resolution myelographic MR images makes segmentation a challenging task. In this paper, we present an automatic tracking method for nerve segmentation based on particle filters. We develop a novel approach to particle representation and dynamics, based on Bézier splines. Moreover, we introduce a robust image likelihood model that enables delineation of nerve bundles and ganglia from the surrounding anatomical structures. We demonstrate accurate and fast nerve tracking and compare it to expert manual segmentation. PMID:22003741
Segmentation of nerve bundles and ganglia in spine MRI using particle filters.
Dalca, Adrian; Danagoulian, Giovanna; Kikinis, Ron; Schmidt, Ehud; Golland, Polina
2011-01-01
Automatic segmentation of spinal nerve bundles that originate within the dural sac and exit the spinal canal is important for diagnosis and surgical planning. The variability in intensity, contrast, shape and direction of nerves seen in high resolution myelographic MR images makes segmentation a challenging task. In this paper, we present an automatic tracking method for nerve segmentation based on particle filters. We develop a novel approach to particle representation and dynamics, based on Bézier splines. Moreover, we introduce a robust image likelihood model that enables delineation of nerve bundles and ganglia from the surrounding anatomical structures. We demonstrate accurate and fast nerve tracking and compare it to expert manual segmentation.
3D Tracking of individual growth factor receptors on polarized cells
NASA Astrophysics Data System (ADS)
Werner, James; Stich, Dominik; Cleyrat, Cedric; Phipps, Mary; Wadinger-Ness, Angela; Wilson, Bridget
We have been developing methods for following 3D motion of selected biomolecular species throughout mammalian cells. Our approach exploits a custom designed confocal microscope that uses a unique spatial filter geometry and active feedback 200 times/second to follow fast 3D motion. By exploiting new non-blinking quantum dots as fluorescence labels, individual molecular trajectories can be observed for several minutes. We also will discuss recent instrument upgrades, including the ability to perform spinning disk fluorescence microscopy on the whole mammalian cell performed simultaneously with 3D molecular tracking experiments. These instrument upgrades were used to quantify 3D heterogeneous transport of individual growth factor receptors (EGFR) on live human renal cortical epithelial cells.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shao, Michael; Nemati, Bijan; Zhai, Chengxing
We present an approach that significantly increases the sensitivity for finding and tracking small and fast near-Earth asteroids (NEAs). This approach relies on a combined use of a new generation of high-speed cameras which allow short, high frame-rate exposures of moving objects, effectively 'freezing' their motion, and a computationally enhanced implementation of the 'shift-and-add' data processing technique that helps to improve the signal-to-noise ratio (SNR) for detection of NEAs. The SNR of a single short exposure of a dim NEA is insufficient to detect it in one frame, but by computationally searching for an appropriate velocity vector, shifting successive framesmore » relative to each other and then co-adding the shifted frames in post-processing, we synthetically create a long-exposure image as if the telescope were tracking the object. This approach, which we call 'synthetic tracking,' enhances the familiar shift-and-add technique with the ability to do a wide blind search, detect, and track dim and fast-moving NEAs in near real time. We discuss also how synthetic tracking improves the astrometry of fast-moving NEAs. We apply this technique to observations of two known asteroids conducted on the Palomar 200 inch telescope and demonstrate improved SNR and 10 fold improvement of astrometric precision over the traditional long-exposure approach. In the past 5 yr, about 150 NEAs with absolute magnitudes H = 28 (∼10 m in size) or fainter have been discovered. With an upgraded version of our camera and a field of view of (28 arcmin){sup 2} on the Palomar 200 inch telescope, synthetic tracking could allow detecting up to 180 such objects per night, including very small NEAs with sizes down to 7 m.« less
Fast Fiber-Coupled Imaging Devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brockington, Samuel; Case, Andrew; Witherspoon, Franklin Douglas
HyperV Technologies Corp. has successfully designed, built and experimentally demonstrated a full scale 1024 pixel 100 MegaFrames/s fiber coupled camera with 12 or 14 bits, and record lengths of 32K frames, exceeding our original performance objectives. This high-pixel-count, fiber optically-coupled, imaging diagnostic can be used for investigating fast, bright plasma events. In Phase 1 of this effort, a 100 pixel fiber-coupled fast streak camera for imaging plasma jet profiles was constructed and successfully demonstrated. The resulting response from outside plasma physics researchers emphasized development of increased pixel performance as a higher priority over increasing pixel count. In this Phase 2more » effort, HyperV therefore focused on increasing the sample rate and bit-depth of the photodiode pixel designed in Phase 1, while still maintaining a long record length and holding the cost per channel to levels which allowed up to 1024 pixels to be constructed. Cost per channel was 53.31 dollars, very close to our original target of $50 per channel. The system consists of an imaging "camera head" coupled to a photodiode bank with an array of optical fibers. The output of these fast photodiodes is then digitized at 100 Megaframes per second and stored in record lengths of 32,768 samples with bit depths of 12 to 14 bits per pixel. Longer record lengths are possible with additional memory. A prototype imaging system with up to 1024 pixels was designed and constructed and used to successfully take movies of very fast moving plasma jets as a demonstration of the camera performance capabilities. Some faulty electrical components on the 64 circuit boards resulted in only 1008 functional channels out of 1024 on this first generation prototype system. We experimentally observed backlit high speed fan blades in initial camera testing and then followed that with full movies and streak images of free flowing high speed plasma jets (at 30-50 km/s). Jet structure and jet collisions onto metal pillars in the path of the plasma jets were recorded in a single shot. This new fast imaging system is an attractive alternative to conventional fast framing cameras for applications and experiments where imaging events using existing techniques are inefficient or impossible. The development of HyperV's new diagnostic was split into two tracks: a next generation camera track, in which HyperV built, tested, and demonstrated a prototype 1024 channel camera at its own facility, and a second plasma community beta test track, where selected plasma physics programs received small systems of a few test pixels to evaluate the expected performance of a full scale camera on their experiments. These evaluations were performed as part of an unfunded collaboration with researchers at Los Alamos National Laboratory and the University of California at Davis. Results from the prototype 1024-pixel camera are discussed, as well as results from the collaborations with test pixel system deployment sites.« less
Real-Time Robust Tracking for Motion Blur and Fast Motion via Correlation Filters
Xu, Lingyun; Luo, Haibo; Hui, Bin; Chang, Zheng
2016-01-01
Visual tracking has extensive applications in intelligent monitoring and guidance systems. Among state-of-the-art tracking algorithms, Correlation Filter methods perform favorably in robustness, accuracy and speed. However, it also has shortcomings when dealing with pervasive target scale variation, motion blur and fast motion. In this paper we proposed a new real-time robust scheme based on Kernelized Correlation Filter (KCF) to significantly improve performance on motion blur and fast motion. By fusing KCF and STC trackers, our algorithm also solve the estimation of scale variation in many scenarios. We theoretically analyze the problem for CFs towards motions and utilize the point sharpness function of the target patch to evaluate the motion state of target. Then we set up an efficient scheme to handle the motion and scale variation without much time consuming. Our algorithm preserves the properties of KCF besides the ability to handle special scenarios. In the end extensive experimental results on benchmark of VOT datasets show our algorithm performs advantageously competed with the top-rank trackers. PMID:27618046
2013-01-01
This paper examines the effects of the Fast Track preventive intervention on youths’ functioning in three domains: disruptive behavior problems, involvement with deviant peers, and social skills during the middle school years. Eight hundred ninety-one children had been randomly assigned by sets of schools within four sites to intervention (n = 445) or to control (n = 446) conditions. In contrast to prior findings of the effectiveness of the Fast Track intervention during the elementary school years, the current findings indicate that Fast Track had little overall impact on children’s functioning in these domains during this age period. There were positive intervention effects on only 2 of 17 outcomes examined. Although the intervention had positive impact on children’s hyperactive and self-reported delinquent behaviors in seventh grade, there were no intervention effects on other externalizing behavior problems or on social skills, and there was a negative intervention effect on children’s involvement with deviant peers during this age period. PMID:24319308
F-16 MMC Strafe in Mountainous Terrain
2016-04-01
19 Figure 10. Steep fast (480 KIAS ) high-angle strafe...a fast (480 KIAS in this example) approach varies from the recovery radius (4000 feet in this case) and down track range prior to recovery initiation...Steep fast (480 KIAS ) high-angle strafe Alternate Analysis The F-16 community, to some extent, has adopted high-angle strafe as the de facto strafe
Neural network fusion capabilities for efficient implementation of tracking algorithms
NASA Astrophysics Data System (ADS)
Sundareshan, Malur K.; Amoozegar, Farid
1996-05-01
The ability to efficiently fuse information of different forms for facilitating intelligent decision-making is one of the major capabilities of trained multilayer neural networks that is being recognized int eh recent times. While development of innovative adaptive control algorithms for nonlinear dynamical plants which attempt to exploit these capabilities seems to be more popular, a corresponding development of nonlinear estimation algorithms using these approaches, particularly for application in target surveillance and guidance operations, has not received similar attention. In this paper we describe the capabilities and functionality of neural network algorithms for data fusion and implementation of nonlinear tracking filters. For a discussion of details and for serving as a vehicle for quantitative performance evaluations, the illustrative case of estimating the position and velocity of surveillance targets is considered. Efficient target tracking algorithms that can utilize data from a host of sensing modalities and are capable of reliably tracking even uncooperative targets executing fast and complex maneuvers are of interest in a number of applications. The primary motivation for employing neural networks in these applications comes form the efficiency with which more features extracted from different sensor measurements can be utilized as inputs for estimating target maneuvers. Such an approach results in an overall nonlinear tracking filter which has several advantages over the popular efforts at designing nonlinear estimation algorithms for tracking applications, the principle one being the reduction of mathematical and computational complexities. A system architecture that efficiently integrates the processing capabilities of a trained multilayer neural net with the tracking performance of a Kalman filter is described in this paper.
Mass tracking and material accounting in the integral fast reactor (IFR)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orechwa, Y.; Adams, C.H.; White, A.M.
1991-01-01
This paper reports on the Integral Fast Reactor (IFR) which is a generic advanced liquid metal cooled reactor concept being developed at Argonne National Laboratory. There are a number of technical features of the IFR which contribute to its potential as a next-generation reactor. These are associated with large safety margins with regard to off-normal events involving the heat transport system, and the use of metallic fuel which makes possible the utilization of innovative fuel cycle processes. The latter feature permits fuel cycle closure with compact, low-cost reprocessing facilities, collocated with the reactor plant. These primary features are being demonstratedmore » in the facilities at ANL-West, utilizing Experimental Breeder Reactor II and the associated Fuel Cycle Facility (FCF) as an IFR prototype. The demonstration of this IFR prototype includes the design and implementation of the Mass-tracking System (MTG). In this system, data from the operations of the FCF, including weights and batch-process parameters, are collected and maintained by the MTG running on distributed workstations.« less
2014-02-01
Children who exhibit early-starting conduct problems are more likely than their peers to initiate sexual activity and substance use at an early age, experience pregnancy, and contract a sexually-transmitted disease [STD], placing them at risk for HIV/AIDS. Hence, understanding the development of multi-problem profiles among youth with early-starting conduct problems may benefit the design of prevention programs. In this study, 1,199 kindergarten children (51% African American; 47% European American; 69% boys) over-sampled for high rates of aggressive-disruptive behavior problems were followed through age 18. Latent class analyses (LCA) were used to define developmental profiles associated with the timing of initiation of sexual activity, tobacco and alcohol/drug use and indicators of risky adolescent sex (e.g. pregnancy and STD). Half of the high-risk children were randomized to a multi-component preventive intervention (Fast Track). The intervention did not significantly reduce membership in the classes characterized by risky sex practices. However, additional analyses examined predictors of poor outcomes, which may inform future prevention efforts.
Jaafar, Haryati; Ibrahim, Salwani; Ramli, Dzati Athiar
2015-01-01
Mobile implementation is a current trend in biometric design. This paper proposes a new approach to palm print recognition, in which smart phones are used to capture palm print images at a distance. A touchless system was developed because of public demand for privacy and sanitation. Robust hand tracking, image enhancement, and fast computation processing algorithms are required for effective touchless and mobile-based recognition. In this project, hand tracking and the region of interest (ROI) extraction method were discussed. A sliding neighborhood operation with local histogram equalization, followed by a local adaptive thresholding or LHEAT approach, was proposed in the image enhancement stage to manage low-quality palm print images. To accelerate the recognition process, a new classifier, improved fuzzy-based k nearest centroid neighbor (IFkNCN), was implemented. By removing outliers and reducing the amount of training data, this classifier exhibited faster computation. Our experimental results demonstrate that a touchless palm print system using LHEAT and IFkNCN achieves a promising recognition rate of 98.64%. PMID:26113861
The Silicon Tracking System of the CBM experiment at FAIR
NASA Astrophysics Data System (ADS)
Teklishyn, Maksym
2018-03-01
The Silicon Tracking System (STS) is the central detector in the Compressed Baryonic Matter (CBM) experiment at FAIR. Operating in the 1Tm dipole magnetic field, the STS will enable pile-up free detection and momentum measurement of the charged particles originating from beam-target nuclear interactions at rates up to 10 MHz. The STS consists of 8 tracking stations based on double-sided silicon micro-strip sensors equipped with fast, self-triggering read-out electronics. With about two million read-out channels, the STS will deliver a high-rate stream of time-stamped data that is transferred to a computing farm for on-line event determination and analysis. The functional building block is a detector module consisting of a sensor, micro-cables and two front-end electronics boards. In this contribution, the development status of the STS components and the system integration is discussed and an outlook on the detector construction is given.
International collaborative project to compare and track the nutritional composition of fast foods.
2012-07-27
Chronic diseases are the leading cause of premature death and disability in the world with over-nutrition a primary cause of diet-related ill health. Excess quantities of energy, saturated fat, sugar and salt derived from fast foods contribute importantly to this disease burden. Our objective is to collate and compare nutrient composition data for fast foods as a means of supporting improvements in product formulation. Surveys of fast foods will be done in each participating country each year. Information on the nutrient composition for each product will be sought either through direct chemical analysis, from fast food companies, in-store materials or from company websites. Foods will be categorized into major groups for the primary analyses which will compare mean levels of saturated fat, sugar, sodium, energy and serving size at baseline and over time. Countries currently involved include Australia, New Zealand, France, UK, USA, India, Spain, China and Canada, with more anticipated to follow. This collaborative approach to the collation and sharing of data will enable low-cost tracking of fast food composition around the world. This project represents a significant step forward in the objective and transparent monitoring of industry and government commitments to improve the quality of fast foods.
UKIRT fast guide system improvements
NASA Astrophysics Data System (ADS)
Balius, Al; Rees, Nicholas P.
1997-09-01
The United Kingdom Infra-Red Telescope (UKIRT) has recently undergone the first major upgrade program since its construction. One part of the upgrade program was an adaptive tip-tilt secondary mirror closed with a CCD system collectively called the fast guide system. The installation of the new secondary and associated systems was carried out in the first half of 1996. Initial testing of the fast guide system has shown great improvement in guide accuracy. The initial installation included a fixed integration time CCD. In the first part of 1997 an integration time controller based on computed guide star luminosity was implemented in the fast guide system. Also, a Kalman type estimator was installed in the image tracking loop based on a dynamic model and knowledge of the statistical properties of the guide star position error measurement as a function of computed guide star magnitude and CCD integration time. The new configuration was tested in terms of improved guide performance nd graceful degradation when tracking faint guide stars. This paper describes the modified fast guide system configuration and reports the results of performance tests.
NASA Astrophysics Data System (ADS)
Bonnin, X.; Aboudarham, J.; Fuller, N.; Renie, C.; Perez-Suarez, D.; Gallagher, P.; Higgins, P.; Krista, L.; Csillaghy, A.; Bentley, R.
2011-12-01
In the frame of the European project HELIO, the Observatoire de Paris-Meudon is in charge of the Heliophysics Feature Catalogue (HFC), a service which provides access to existing solar and heliospheric feature data. In order to create a catalogue as exhaustive as possible, recognition codes are developed to automatically detect and track features. At the time, HFC contains data of filaments, active regions, coronal holes, sunspots and type III radio bursts for a full solar cycle. The insertion of prominences and type II radio bursts should be done in the short term. We present here an overview of some of the algorithms used to populate HFC. The development of such fast and robust techniques also addresses the needs of the Space Weather community in terms of near real-time monitoring capabilities.
Automated tracking and quantification of angiogenic vessel formation in 3D microfluidic devices.
Wang, Mengmeng; Ong, Lee-Ling Sharon; Dauwels, Justin; Asada, H Harry
2017-01-01
Angiogenesis, the growth of new blood vessels from pre-existing vessels, is a critical step in cancer invasion. Better understanding of the angiogenic mechanisms is required to develop effective antiangiogenic therapies for cancer treatment. We culture angiogenic vessels in 3D microfluidic devices under different Sphingosin-1-phosphate (S1P) conditions and develop an automated vessel formation tracking system (AVFTS) to track the angiogenic vessel formation and extract quantitative vessel information from the experimental time-lapse phase contrast images. The proposed AVFTS first preprocesses the experimental images, then applies a distance transform and an augmented fast marching method in skeletonization, and finally implements the Hungarian method in branch tracking. When applying the AVFTS to our experimental data, we achieve 97.3% precision and 93.9% recall by comparing with the ground truth obtained from manual tracking by visual inspection. This system enables biologists to quantitatively compare the influence of different growth factors. Specifically, we conclude that the positive S1P gradient increases cell migration and vessel elongation, leading to a higher probability for branching to occur. The AVFTS is also applicable to distinguish tip and stalk cells by considering the relative cell locations in a branch. Moreover, we generate a novel type of cell lineage plot, which not only provides cell migration and proliferation histories but also demonstrates cell phenotypic changes and branch information.
SCOUT: A Fast Monte-Carlo Modeling Tool of Scintillation Camera Output
Hunter, William C. J.; Barrett, Harrison H.; Lewellen, Thomas K.; Miyaoka, Robert S.; Muzi, John P.; Li, Xiaoli; McDougald, Wendy; MacDonald, Lawrence R.
2011-01-01
We have developed a Monte-Carlo photon-tracking and readout simulator called SCOUT to study the stochastic behavior of signals output from a simplified rectangular scintillation-camera design. SCOUT models the salient processes affecting signal generation, transport, and readout. Presently, we compare output signal statistics from SCOUT to experimental results for both a discrete and a monolithic camera. We also benchmark the speed of this simulation tool and compare it to existing simulation tools. We find this modeling tool to be relatively fast and predictive of experimental results. Depending on the modeled camera geometry, we found SCOUT to be 4 to 140 times faster than other modeling tools. PMID:22072297
SCOUT: a fast Monte-Carlo modeling tool of scintillation camera output†
Hunter, William C J; Barrett, Harrison H.; Muzi, John P.; McDougald, Wendy; MacDonald, Lawrence R.; Miyaoka, Robert S.; Lewellen, Thomas K.
2013-01-01
We have developed a Monte-Carlo photon-tracking and readout simulator called SCOUT to study the stochastic behavior of signals output from a simplified rectangular scintillation-camera design. SCOUT models the salient processes affecting signal generation, transport, and readout of a scintillation camera. Presently, we compare output signal statistics from SCOUT to experimental results for both a discrete and a monolithic camera. We also benchmark the speed of this simulation tool and compare it to existing simulation tools. We find this modeling tool to be relatively fast and predictive of experimental results. Depending on the modeled camera geometry, we found SCOUT to be 4 to 140 times faster than other modeling tools. PMID:23640136
The use of ultrasonic properties of CR-39 track detectors in neutron dosimetry
NASA Astrophysics Data System (ADS)
Afifi, H.; El-Sersy, A.; Khaled, N.
2004-01-01
The longitudinal and shear wave ultrasonic velocities have been measured before and after exposing 5-mm thick CR-39 solid state nuclear track detectors to both a mixed field of gamma-rays and fast neutrons from an Am-Be source in the ranges from 0 to 10 4 mSv. The change in the intermolecular structure as caused by the fast neutron exposure was studied by the ultrasonic pulse echo method at a frequency of 2 MHz and at room temperature. The elastic coefficients, Poisson's ratio, microhardness, ultrasonic absorption coefficient and internal friction have been determined. The study shows that the gamma-ray irradiation had no effect on the ultrasonic properties of CR-39 at least at the used doses. However, all the ultrasonic properties are influenced by the fast neutrons at doses up to 10 4 mSv. Our experimental results confirmed that the ultrasonic technique is useful for fast neutron detection, by exploiting the differences in mechanical properties of CR-39.
Global fast dynamic terminal sliding mode control for a quadrotor UAV.
Xiong, Jing-Jing; Zhang, Guo-Bao
2017-01-01
A control method based on global fast dynamic terminal sliding mode control (TSMC) technique is proposed to design the flight controller for performing the finite-time position and attitude tracking control of a small quadrotor UAV. Firstly, the dynamic model of the quadrotor is divided into two subsystems, i.e., a fully actuated subsystem and an underactuated subsystem. Secondly, the dynamic flight controllers of the quadrotor are formulated based on global fast dynamic TSMC, which is able to guarantee that the position and velocity tracking errors of all system state variables converge to zero in finite-time. Moreover, the global fast dynamic TSMC is also able to eliminate the chattering phenomenon caused by the switching control action and realize the high precision performance. In addition, the stabilities of two subsystems are demonstrated by Lyapunov theory, respectively. Lastly, the simulation results are given to illustrate the effectiveness and robustness of the proposed control method in the presence of external disturbances. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Three-dimensional reconstruction of the fast-start swimming kinematics of densely schooling fish
Paley, Derek A.
2012-01-01
Information transmission via non-verbal cues such as a fright response can be quantified in a fish school by reconstructing individual fish motion in three dimensions. In this paper, we describe an automated tracking framework to reconstruct the full-body trajectories of densely schooling fish using two-dimensional silhouettes in multiple cameras. We model the shape of each fish as a series of elliptical cross sections along a flexible midline. We estimate the size of each ellipse using an iterated extended Kalman filter. The shape model is used in a model-based tracking framework in which simulated annealing is applied at each step to estimate the midline. Results are presented for eight fish with occlusions. The tracking system is currently being used to investigate fast-start behaviour of schooling fish in response to looming stimuli. PMID:21642367
Fomenko, V; Moreno, B; Million, M; Harrison, J; Akselrod, M
2017-10-25
The neutron-energy dependence of the track-counting sensitivity of fluorescent nuclear track detectors (FNTDs) at two ranges of Mg doping, resulting in different crystal colorations, was investigated. The performance of FNTDs was studied with the following converters: Li-glass for thermal to intermediate-energy neutrons, polyethylene for fast neutrons, and polytetrafluoroethylene (Teflon™) for photon- and radon-background subtraction. The irradiations with monoenergetic neutrons were performed at the National Physics Laboratory (NPL), UK. The energy range was varied from 144 keV to 16.5 MeV in the personal dose equivalent range from 1 to 3 mSv. Monte Carlo simulations were performed to model the response of FNTDs to monoenergetic neutrons. A good agreement with the experimental data was observed suggesting the development of a basic model for future MC studies. Further work will focus on increasing FNTD sensitivity to low-energy neutrons and developing a faster imaging technique for scanning larger areas to improve counting statistics. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Mikic, I.; Krucinski, S.; Thomas, J. D.
1998-01-01
This paper presents a method for segmentation and tracking of cardiac structures in ultrasound image sequences. The developed algorithm is based on the active contour framework. This approach requires initial placement of the contour close to the desired position in the image, usually an object outline. Best contour shape and position are then calculated, assuming that at this configuration a global energy function, associated with a contour, attains its minimum. Active contours can be used for tracking by selecting a solution from a previous frame as an initial position in a present frame. Such an approach, however, fails for large displacements of the object of interest. This paper presents a technique that incorporates the information on pixel velocities (optical flow) into the estimate of initial contour to enable tracking of fast-moving objects. The algorithm was tested on several ultrasound image sequences, each covering one complete cardiac cycle. The contour successfully tracked boundaries of mitral valve leaflets, aortic root and endocardial borders of the left ventricle. The algorithm-generated outlines were compared against manual tracings by expert physicians. The automated method resulted in contours that were within the boundaries of intraobserver variability.
Controlled Blasting for Deconstruction of a Railway Bridge Near Sahibganj
NASA Astrophysics Data System (ADS)
Mandal, S. K.; Ghosh, A. K.; Oraon, S.
2018-06-01
Some of the Indian Railway bridges require reconstruction for electrification and expansion of railway tracks. Dismantling of bridge within time schedule in densely populated area requires controlled and pre-planned blasting methodology for safe pulling down of the structure and quick removal of blasted debris for fast restoration of tracks and smooth plying of trains. The three arched railway bridge (Bridge No. 61) located between Sahibganj and Karamtola cases one such example where the bridge was dismantled and the track was restored within 4 h of blasting, though the stipulated block period for demolition and restoration of tracks was 6 h. The 25.48 m long three-arched bridge was drilled and blasted with 225 number of blastholes (32 mm diameter) and 100 kg explosive (25 mm diameter). Length of blastholes varied between 0.5 and 1.8 m with blast geometry of 0.3-0.35 m burden and 0.33 m spacing. This paper deals with the conceptual and theoretical model developed for identification of the key locations for drilling and implementation of the same. It also discusses about the precautionary measures and the drilling pattern adopted for quick demolition and speedy restoration of tracks.
Controlled Blasting for Deconstruction of a Railway Bridge Near Sahibganj
NASA Astrophysics Data System (ADS)
Mandal, S. K.; Ghosh, A. K.; Oraon, S.
2018-02-01
Some of the Indian Railway bridges require reconstruction for electrification and expansion of railway tracks. Dismantling of bridge within time schedule in densely populated area requires controlled and pre-planned blasting methodology for safe pulling down of the structure and quick removal of blasted debris for fast restoration of tracks and smooth plying of trains. The three arched railway bridge (Bridge No. 61) located between Sahibganj and Karamtola cases one such example where the bridge was dismantled and the track was restored within 4 h of blasting, though the stipulated block period for demolition and restoration of tracks was 6 h. The 25.48 m long three-arched bridge was drilled and blasted with 225 number of blastholes (32 mm diameter) and 100 kg explosive (25 mm diameter). Length of blastholes varied between 0.5 and 1.8 m with blast geometry of 0.3-0.35 m burden and 0.33 m spacing. This paper deals with the conceptual and theoretical model developed for identification of the key locations for drilling and implementation of the same. It also discusses about the precautionary measures and the drilling pattern adopted for quick demolition and speedy restoration of tracks.
Analysis of three advanced practice roles in emergency nursing.
Considine, Julie; Lucas, Elspeth; Payne, Roslyn; Kropman, Matthew; Stergiou, Helen E; Chiu, Herman
2012-11-01
There are many Emergency Department (ED) demand management systems that include advanced practice emergency nursing roles. The aim of this study is to examine and compare three advanced emergency nursing practice roles: ED Fast Track, Clinical Initiatives Nurse (CIN) and Rapid Intervention and Treatment Zone (RITZ). A descriptive exploratory approach was used to conduct this study at an urban district hospital in Melbourne, Australia. The study participants were patients managed in each of the three systems with advanced practice emergency nursing roles: Fast Track, CIN and RITZ. There were a total of 551 patients: 195 Fast Track patients, 163 CIN managed patients and 193 RITZ patients. CIN managed patients were older (p<0.001), with higher levels of clinical urgency (p<0.001), and higher hospital admission rates (p<0.001). CIN managed patients had shorter waiting time for nursing care (p=0.001) and lower incidence of medical assessment within the time associated with their triage category (p<0.0001). ED LOS for discharged patients was significantly longer for CIN managed patients (p<0.001). CIN managed patients had a significantly higher incidence of electrocardiography (p<0.001), blood glucose measurement (p<0.001), intravenous cannulation (p<0.001), pathology testing (p<0.001), and analgesia administration (p<0.001) when compared to Fast Track and RITZ patients. Advanced practice roles in emergency nursing can have different applications in the ED context. Clarity about role intent and scope of practice is important and should inform educational preparation and teams within which these roles operate. Copyright © 2012 College of Emergency Nursing Australasia Ltd. Published by Elsevier Ltd. All rights reserved.
Rhou, Yoon J J; Pather, Selvan; Loadsman, John A; Campbell, Neil; Philp, Shannon; Carter, Jonathan
2015-12-01
To assess the direct intraoperative and postoperative costs in women undergoing total laparoscopic hysterectomy and fast-track open hysterectomy. A retrospective review of the direct hospital-related costs in a matched cohort of women undergoing total laparoscopic hysterectomy (TLH) and fast-track open hysterectomy (FTOH) at a tertiary hospital. All costs were calculated, including the cost of advanced high-energy laparoscopic devices. The effect of the learning curve on cost in laparoscopic hysterectomy was also assessed, as was the hospital case-weighted cost, which was compared with the actual cost. Fifty women were included in each arm of the study. TLH had a higher intraoperative cost, but a lower postoperative cost than FTOH (AUD$3877 vs AUD$2776 P < 0.001, AUD$3965 vs AUD$6233 P < 0.001). The total cost of TLH was not different from FTOH (AUD$7842 vs AUD$9009 P = 0.068) and after a learning curve; TLH cost less than FTOH (AUD$6797 vs AUD$8647, P < 0.001). The use of high-energy devices did not impact on the cost benefit of TLH, and hospital case-weight-based funding correlated poorly with actual cost. Despite the use of fast-track recovery protocols, the cost of TLH is no different to FTOH and after a learning curve is cheaper than open hysterectomy. Judicious use of advanced energy devices does not impact on the cost, and hospital case-weight-based funding model in our hospital is inaccurate when compared to directly calculated hospital costs. © 2013 The Authors ANZJOG © 2013 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.
Prehn, Alexander; Glöckner, Rosa; Rempe, Gerhard; Zeppenfeld, Martin
2017-03-01
Optical frequency combs (OFCs) provide a convenient reference for the frequency stabilization of continuous-wave lasers. We demonstrate a frequency control method relying on tracking over a wide range and stabilizing the beat note between the laser and the OFC. The approach combines fast frequency ramps on a millisecond timescale in the entire mode-hop free tuning range of the laser and precise stabilization to single frequencies. We apply it to a commercially available optical parametric oscillator (OPO) and demonstrate tuning over more than 60 GHz with a ramping speed up to 3 GHz/ms. Frequency ramps spanning 15 GHz are performed in less than 10 ms, with the OPO instantly relocked to the OFC after the ramp at any desired frequency. The developed control hardware and software are able to stabilize the OPO to sub-MHz precision and to perform sequences of fast frequency ramps automatically.
Weisshaar, D.; Bazin, D.; Bender, P. C.; ...
2016-12-03
The gamma-ray tracking array GRETINA was coupled to the S800 magnetic spectrometer for spectroscopy with fast beams of rare isotopes at the National Superconducting Cyclotron Laboratory on the campus of Michigan State University. We describe the technical details of this powerful setup and report on GRETINA's performance achieved with source and in-beam measurements. The gamma-ray multiplicity encountered in experiments with fast beams is usually low, allowing for a simplified and efficient treatment of the data in the gamma-ray analysis in terms of Doppler reconstruction and spectral quality. Finally, the results reported in this work were obtained from GRETINA consisting ofmore » 8 detector modules hosting four high-purity germanium crystals each. Currently, GRETINA consists of 10 detector modules.« less
An object detection and tracking system for unmanned surface vehicles
NASA Astrophysics Data System (ADS)
Yang, Jian; Xiao, Yang; Fang, Zhiwen; Zhang, Naiwen; Wang, Li; Li, Tao
2017-10-01
Object detection and tracking are critical parts of unmanned surface vehicles(USV) to achieve automatic obstacle avoidance. Off-the-shelf object detection methods have achieved impressive accuracy in public datasets, though they still meet bottlenecks in practice, such as high time consumption and low detection quality. In this paper, we propose a novel system for USV, which is able to locate the object more accurately while being fast and stable simultaneously. Firstly, we employ Faster R-CNN to acquire several initial raw bounding boxes. Secondly, the image is segmented to a few superpixels. For each initial box, the superpixels inside will be grouped into a whole according to a combination strategy, and a new box is thereafter generated as the circumscribed bounding box of the final superpixel. Thirdly, we utilize KCF to track these objects after several frames, Faster-RCNN is again used to re-detect objects inside tracked boxes to prevent tracking failure as well as remove empty boxes. Finally, we utilize Faster R-CNN to detect objects in the next image, and refine object boxes by repeating the second module of our system. The experimental results demonstrate that our system is fast, robust and accurate, which can be applied to USV in practice.
Fast track in colo-rectal surgery. Preliminary experience in a rural hospital
FRONTERA, D.; ARENA, L.; CORSALE, I.; FRANCIOLI, N.; MAMMOLITI, F.; BUCCIANELLI, E.
2014-01-01
Background “Fast Track surgery” is a therapeutic program of large application, despite some doubts about its applicability and real validity. Literature review shows that this approach to colo-rectal surgery, particularly video-assisted, can allow a rapid recovery, better performance and a faster postoperative functional autonomy of the work, which can be discharged without cause additional welfare costs; in addition it can be reproducible in different health reality. Purpose To analyze the possibility to apply the Fast Truck protocol in patients undergoing colorectal surgery in a rural hospital and non specialistic Unit of Surgery. Patients and methods We have conducted a prospective, randomized study on 80 patients subjected to colorectal surgery in the last year. Results The protocol was observed in 95% of cases, compliance with the Fast Track was high and general morbidity was limited (7.8%). Conclusion This “aggressive” approach, which has fundamentally altered the usual surgical behavior, seems to allow a mean length of stay significantly lower than in controls (p < 0.05) with positive implications for patients and containment of health care costs, even after discharge (no need for home care in 92% of cases, no early re-admittance to the hospital). Homogeneous protocols are desirable, as well as an increased enrollment, to consolidate these rehabilitation programs in order to provide a reference for all hospitals. PMID:25644732
NASA Astrophysics Data System (ADS)
Fang, W.; Quan, S. H.; Xie, C. J.; Tang, X. F.; Wang, L. L.; Huang, L.
2016-03-01
In this study, a direct-current/direct-current (DC/DC) converter with maximum power point tracking (MPPT) is developed to down-convert the high voltage DC output from a thermoelectric generator to the lower voltage required to charge batteries. To improve the tracking accuracy and speed of the converter, a novel MPPT control scheme characterized by an aggregated dichotomy and gradient (ADG) method is proposed. In the first stage, the dichotomy algorithm is used as a fast search method to find the approximate region of the maximum power point. The gradient method is then applied for rapid and accurate tracking of the maximum power point. To validate the proposed MPPT method, a test bench composed of an automobile exhaust thermoelectric generator was constructed for harvesting the automotive exhaust heat energy. Steady-state and transient tracking experiments under five different load conditions were carried out using a DC/DC converter with the proposed ADG and with three traditional methods. The experimental results show that the ADG method can track the maximum power within 140 ms with a 1.1% error rate when the engine operates at 3300 rpm@71 NM, which is superior to the performance of the single dichotomy method, the single gradient method and the perturbation and observation method from the viewpoint of improved tracking accuracy and speed.
The flex track: flexible partitioning between low- and high-acuity areas of an emergency department.
Laker, Lauren F; Froehle, Craig M; Lindsell, Christopher J; Ward, Michael J
2014-12-01
Emergency departments (EDs) with both low- and high-acuity treatment areas often have fixed allocation of resources, regardless of demand. We demonstrate the utility of discrete-event simulation to evaluate flexible partitioning between low- and high-acuity ED areas to identify the best operational strategy for subsequent implementation. A discrete-event simulation was used to model patient flow through a 50-bed, urban, teaching ED that handles 85,000 patient visits annually. The ED has historically allocated 10 beds to a fast track for low-acuity patients. We estimated the effect of a flex track policy, which involved switching up to 5 of these fast track beds to serving both low- and high-acuity patients, on patient waiting times. When the high-acuity beds were not at capacity, low-acuity patients were given priority access to flexible beds. Otherwise, high-acuity patients were given priority access to flexible beds. Wait times were estimated for patients by disposition and Emergency Severity Index score. A flex track policy using 3 flexible beds produced the lowest mean patient waiting time of 30.9 minutes (95% confidence interval [CI] 30.6 to 31.2 minutes). The typical fast track approach of rigidly separating high- and low-acuity beds produced a mean patient wait time of 40.6 minutes (95% CI 40.2 to 50.0 minutes), 31% higher than that of the 3-bed flex track. A completely flexible ED, in which all beds can accommodate any patient, produced mean wait times of 35.1 minutes (95% CI 34.8 to 35.4 minutes). The results from the 3-bed flex track scenario were robust, performing well across a range of scenarios involving higher and lower patient volumes and care durations. Using discrete-event simulation, we have shown that adding some flexibility into bed allocation between low and high acuity can provide substantial reductions in overall patient waiting and a more efficient ED. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Dual linear structured support vector machine tracking method via scale correlation filter
NASA Astrophysics Data System (ADS)
Li, Weisheng; Chen, Yanquan; Xiao, Bin; Feng, Chen
2018-01-01
Adaptive tracking-by-detection methods based on structured support vector machine (SVM) performed well on recent visual tracking benchmarks. However, these methods did not adopt an effective strategy of object scale estimation, which limits the overall tracking performance. We present a tracking method based on a dual linear structured support vector machine (DLSSVM) with a discriminative scale correlation filter. The collaborative tracker comprised of a DLSSVM model and a scale correlation filter obtains good results in tracking target position and scale estimation. The fast Fourier transform is applied for detection. Extensive experiments show that our tracking approach outperforms many popular top-ranking trackers. On a benchmark including 100 challenging video sequences, the average precision of the proposed method is 82.8%.
SET: a pupil detection method using sinusoidal approximation
Javadi, Amir-Homayoun; Hakimi, Zahra; Barati, Morteza; Walsh, Vincent; Tcheang, Lili
2015-01-01
Mobile eye-tracking in external environments remains challenging, despite recent advances in eye-tracking software and hardware engineering. Many current methods fail to deal with the vast range of outdoor lighting conditions and the speed at which these can change. This confines experiments to artificial environments where conditions must be tightly controlled. Additionally, the emergence of low-cost eye tracking devices calls for the development of analysis tools that enable non-technical researchers to process the output of their images. We have developed a fast and accurate method (known as “SET”) that is suitable even for natural environments with uncontrolled, dynamic and even extreme lighting conditions. We compared the performance of SET with that of two open-source alternatives by processing two collections of eye images: images of natural outdoor scenes with extreme lighting variations (“Natural”); and images of less challenging indoor scenes (“CASIA-Iris-Thousand”). We show that SET excelled in outdoor conditions and was faster, without significant loss of accuracy, indoors. SET offers a low cost eye-tracking solution, delivering high performance even in challenging outdoor environments. It is offered through an open-source MATLAB toolkit as well as a dynamic-link library (“DLL”), which can be imported into many programming languages including C# and Visual Basic in Windows OS (www.eyegoeyetracker.co.uk). PMID:25914641
A maximum power point tracking algorithm for buoy-rope-drum wave energy converters
NASA Astrophysics Data System (ADS)
Wang, J. Q.; Zhang, X. C.; Zhou, Y.; Cui, Z. C.; Zhu, L. S.
2016-08-01
The maximum power point tracking control is the key link to improve the energy conversion efficiency of wave energy converters (WEC). This paper presents a novel variable step size Perturb and Observe maximum power point tracking algorithm with a power classification standard for control of a buoy-rope-drum WEC. The algorithm and simulation model of the buoy-rope-drum WEC are presented in details, as well as simulation experiment results. The results show that the algorithm tracks the maximum power point of the WEC fast and accurately.
Fast and Accurate Cell Tracking by a Novel Optical-Digital Hybrid Method
NASA Astrophysics Data System (ADS)
Torres-Cisneros, M.; Aviña-Cervantes, J. G.; Pérez-Careta, E.; Ambriz-Colín, F.; Tinoco, Verónica; Ibarra-Manzano, O. G.; Plascencia-Mora, H.; Aguilera-Gómez, E.; Ibarra-Manzano, M. A.; Guzman-Cabrera, R.; Debeir, Olivier; Sánchez-Mondragón, J. J.
2013-09-01
An innovative methodology to detect and track cells using microscope images enhanced by optical cross-correlation techniques is proposed in this paper. In order to increase the tracking sensibility, image pre-processing has been implemented as a morphological operator on the microscope image. Results show that the pre-processing process allows for additional frames of cell tracking, therefore increasing its robustness. The proposed methodology can be used in analyzing different problems such as mitosis, cell collisions, and cell overlapping, ultimately designed to identify and treat illnesses and malignancies.
Trajectory tracking and backfitting techniques against theater ballistic missiles
NASA Astrophysics Data System (ADS)
Hutchins, Robert G.; Britt, Patrick T.
1999-10-01
Since the SCUD launches in the Gulf War, theater ballistic missile (TBM) systems have become a growing concern for the US military. Detection, fast track initiation, backfitting for launch point determination, and tracking and engagement during boost phase or shortly after booster cutoff are goals that grow in importance with the proliferation of weapons of mass destruction. This paper focuses on track initiation and backfitting techniques, as well as extending some earlier results on tracking a TBM during boost phase cutoff. Results indicate that Kalman techniques are superior to third order polynomial extrapolations in estimating the launch point, and that some knowledge of missile parameters, especially thrust, is extremely helpful in track initiation.
Fast Deep Tracking via Semi-Online Domain Adaptation
NASA Astrophysics Data System (ADS)
Li, Xiaoping; Luo, Wenbing; Zhu, Yi; Li, Hanxi; Wang, Mingwen
2018-04-01
Deep tracking has been illustrating overwhelming superiorities over the shallow methods. Unfortunately, it also suffers from low FPS rates. To alleviate the problem, a number of real-time deep trackers have been proposed via removing the online updating procedure on the CNN model. However, the absent of the online update leads to a significant drop on tracking accuracy. In this work, we propose to perform the domain adaptation for visual tracking in two stages for transferring the information from the visual tracking domain and the instance domain respectively. In this way, the proposed visual tracker achieves comparable tracking accuracy to the state-of-the-art trackers and runs at real-time speed on an average consuming GPU.
Tracking multiple objects is limited only by object spacing, not by speed, time, or capacity.
Franconeri, S L; Jonathan, S V; Scimeca, J M
2010-07-01
In dealing with a dynamic world, people have the ability to maintain selective attention on a subset of moving objects in the environment. Performance in such multiple-object tracking is limited by three primary factors-the number of objects that one can track, the speed at which one can track them, and how close together they can be. We argue that this last limit, of object spacing, is the root cause of all performance constraints in multiple-object tracking. In two experiments, we found that as long as the distribution of object spacing is held constant, tracking performance is unaffected by large changes in object speed and tracking time. These results suggest that barring object-spacing constraints, people could reliably track an unlimited number of objects as fast as they could track a single object.
FAST TRACK COMMUNICATION: Stable propagation of a modulated positron beam in a bent crystal channel
NASA Astrophysics Data System (ADS)
Kostyuk, A.; Korol, A. V.; Solov'yov, A. V.; Greiner, W.
2010-08-01
The propagation of a modulated positron beam in a planar crystal channel is investigated. It is demonstrated that the beam preserves its modulation at sufficiently large penetration depths, which opens the prospect of using a crystalline undulator as a coherent source of hard x-rays. This finding is a crucial milestone in developing a new type of laser radiating in the hard x-ray and gamma-ray range.
Reusable launch vehicle development research
NASA Technical Reports Server (NTRS)
1995-01-01
NASA has generated a program approach for a SSTO reusable launch vehicle technology (RLV) development which includes a follow-on to the Ballistic Missile Defense Organization's (BMDO) successful DC-X program, the DC-XA (Advanced). Also, a separate sub-scale flight demonstrator, designated the X-33, will be built and flight tested along with numerous ground based technologies programs. For this to be a successful effort, a balance between technical, schedule, and budgetary risks must be attained. The adoption of BMDO's 'fast track' management practices will be a key element in the eventual success of NASA's effort.
Modification of a medical PET scanner for PEPT studies
NASA Astrophysics Data System (ADS)
Sadrmomtaz, Alireza; Parker, D. J.; Byars, L. G.
2007-04-01
Over the last 20 years, positron emission tomography (PET) has developed as the most powerful functional imaging modality in medicine. Over the same period the University of Birmingham Positron Imaging Centre has applied PET to study engineering processes and developed the alternative technique of positron emission particle tracking (PEPT) in which a single radioactively labelled tracer particle is tracked by detecting simultaneously the pairs of back-to-back photons arising from positron/electron annihilation. Originally PEPT was performed using a pair of multiwire detectors, and more recently using a pair of digital gamma camera heads. In 2002 the Positron Imaging Centre acquired a medical PET scanner, an ECAT 931/08, previously used at Hammersmith Hospital. This scanner has been rebuilt in a flexible geometry for use in PEPT studies. This paper presents initial results from this system. Fast moving tracer particles can be rapidly and accurately located.
Dong, Hongyang; Hu, Qinglei; Ma, Guangfu
2016-03-01
Study results of developing control system for spacecraft formation proximity operations between a target and a chaser are presented. In particular, a coupled model using dual quaternion is employed to describe the proximity problem of spacecraft formation, and a nonlinear adaptive fault-tolerant feedback control law is developed to enable the chaser spacecraft to track the position and attitude of the target even though its actuator occurs fault. Multiple-task capability of the proposed control system is further demonstrated in the presence of disturbances and parametric uncertainties as well. In addition, the practical finite-time stability feature of the closed-loop system is guaranteed theoretically under the designed control law. Numerical simulation of the proposed method is presented to demonstrate the advantages with respect to interference suppression, fast tracking, fault tolerant and practical finite-time stability. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.
A novel graphical user interface for ultrasound-guided shoulder arthroscopic surgery
NASA Astrophysics Data System (ADS)
Tyryshkin, K.; Mousavi, P.; Beek, M.; Pichora, D.; Abolmaesumi, P.
2007-03-01
This paper presents a novel graphical user interface developed for a navigation system for ultrasound-guided computer-assisted shoulder arthroscopic surgery. The envisioned purpose of the interface is to assist the surgeon in determining the position and orientation of the arthroscopic camera and other surgical tools within the anatomy of the patient. The user interface features real time position tracking of the arthroscopic instruments with an optical tracking system, and visualization of their graphical representations relative to a three-dimensional shoulder surface model of the patient, created from computed tomography images. In addition, the developed graphical interface facilitates fast and user-friendly intra-operative calibration of the arthroscope and the arthroscopic burr, capture and segmentation of ultrasound images, and intra-operative registration. A pilot study simulating the computer-aided shoulder arthroscopic procedure on a shoulder phantom demonstrated the speed, efficiency and ease-of-use of the system.
NASA Astrophysics Data System (ADS)
Tsai, Hui-Chen; Chang, Chun-Fang; Chen, Bi-Chang; Cheng, Ji-Yen; Chu, Chih-Wei; Han, Hsieh-Cheng; Hatanaka, Koji; Hsieh, Tung-Han; Lee, Chau-Hwang; Lin, Jung-Hsin; Tung, Yi-Chung; Wei, Pei-Kuen; Yang, Fu-Liang; Tsai, Din Ping
2015-12-01
Development of imaging, sensing, and characterization of cells at Research Center for Applied Sciences (RCAS) of Academia Sinica in Taiwan is progressing rapidly. The research on advanced lattice light sheet microscopy for temporal visualization of cells in three dimensions at sub-cellular resolution shows novel imaging results. Label-free observation on filopodial dynamics provides a convenient assay on cancer cell motility. The newly-developed software enables us to track the movement of two types of particles through different channels and reconstruct the co-localized tracks. Surface plasmon resonance (SPR) for detecting urinary microRNA for diagnosis of acute kidney injury demonstrates excellent sensitivity. A fully automated and integrated portable reader was constructed as a home-based surveillance system for post-operation hepatocellular carcinoma. New microfluidic cell culture devices for fast and accurate characterizations prove various diagnosis capabilities.
Fast Track to the Cloud: Design Patterns for 12-Factor Earth Sciences Applications
NASA Technical Reports Server (NTRS)
Pawloski, Andrew; McLaughlin, Brett; Lynnes, Christopher
2016-01-01
As expanding service offerings and decreasing prices make the cloud increasingly attractive to Earth Science applications, there are nontrivial practical considerations which can hinder its meaningful use. In this talk, we will discuss architectural recommendations and lessons learned while working on EOSDIS' cloud efforts, particularly the NASA-compliant General Application Platform (NGAP) and its associated applications. Prominent in our findings is the importance of 12-factor design patterns and the powerful "wins" they enable in the cloud. We will share our strategies for "fast-tracking" applications to the cloud --whether they be legacy, planned for the future, or somewhere in between.
Hasenberg, T; Keese, M; Längle, F; Reibenwein, B; Schindler, K; Herold, A; Beck, G; Post, S; Jauch, K W; Spies, C; Schwenk, W; Shang, E
2009-02-01
'Fast-track' rehabilitation has been shown to accelerate recovery, reduce general morbidity and decrease hospital stay after elective colonic surgery. Despite this evidence, there is no information on the acceptance and utilization of these concepts among the entirety of Austrian and German surgeons. In 2006, a questionnaire concerning perioperative routines in elective, open colonic resection was sent to the chief surgeons of 1270 German and 120 Austrian surgical centres. The response rate was 63% in Austria (76 centres) and 30% in Germany (385 centres). Mechanical bowel preparation is used by the majority (Austria, 91%; Germany, 94%); the vertical incision is the standard method of approach to the abdomen in Austria (79%) and Germany (83%), nasogastric decompression tubes are rarely used, one-third of the questioned surgeons in both countries use intra-abdominal drains. Half of the surgical centres allow the intake of clear fluids on the day of surgery and one-fifth offer solid food on that day. Epidural analgesia is used in three-fourths of the institutions. Although there is an evident benefit of fast-track management, the survey shows that they are not yet widely used as a routine in Austria and Germany.
The use of a break-even analysis: financial analysis of a fast-track program.
Saywell, R M; Cordell, W H; Nyhuis, A W; Giles, B K; Culler, S D; Woods, J R; Chu, D K; McKinzie, J P; Rodman, G H
1995-08-01
To calculate the financial break-even point and illustrate how changes in third-party reimbursement and eligibility could affect a program's fiscal standing. Demographic, clinical, and financial data were collected retrospectively for 446 patients treated in a fast-track program during June 1993. The fast-track program is located within the confines of the emergency medicine and trauma center at a 1,050-bed tertiary care Midwestern teaching hospital and provides urgent treatment to minimally ill patients. A financial break-even analysis was performed to determine the point where the program generated enough revenue to cover its total variable and fixed costs, both direct and indirect. Given the relatively low average collection rate (62%) and high percentage of uninsured patients (31%), the analysis showed that the program's revenues covered its direct costs but not all of the indirect costs. Examining collection rates or payer class mix without examining both costs and revenues may lead to an erroneous conclusion about a program's fiscal viability. Sensitivity analysis also shows that relatively small changes in third-party coverage or eligibility (income) requirements can have a large impact on the program's financial solvency and break-even volumes.
A hardware fast tracker for the ATLAS trigger
NASA Astrophysics Data System (ADS)
Asbah, Nedaa
2016-09-01
The trigger system of the ATLAS experiment is designed to reduce the event rate from the LHC nominal bunch crossing at 40 MHz to about 1 kHz, at the design luminosity of 1034 cm-2 s-1. After a successful period of data taking from 2010 to early 2013, the LHC already started with much higher instantaneous luminosity. This will increase the load on High Level Trigger system, the second stage of the selection based on software algorithms. More sophisticated algorithms will be needed to achieve higher background rejection while maintaining good efficiency for interesting physics signals. The Fast TracKer (FTK) is part of the ATLAS trigger upgrade project. It is a hardware processor that will provide, at every Level-1 accepted event (100 kHz) and within 100 microseconds, full tracking information for tracks with momentum as low as 1 GeV. Providing fast, extensive access to tracking information, with resolution comparable to the offline reconstruction, FTK will help in precise detection of the primary and secondary vertices to ensure robust selections and improve the trigger performance. FTK exploits hardware technologies with massive parallelism, combining Associative Memory ASICs, FPGAs and high-speed communication links.
Scardino, Marco; D'Amato, Tiziana; Martorelli, Federica; Fenocchio, Giorgia; Simili, Vincenzo; Di Matteo, Berardo; Bugada, Dario; Kon, Elizaveta
2018-03-20
Currently many TKA protocols rely on multimodal analgesic protocols with patient-controlled analgesia systems that administer opioids through a patient controlled IV infusion pump, in addition to concomitant peripheral nerve blocks and local anesthetics. Although effective, PCA IV opioids do not provide optimal results with fast track rehabilitation protocols. The present is a retrospective study comparing the novel sublingual sufentanil PCA system (SSTS) to our standard of care foreseeing continuous femoral nerve block (cFNB) within a multimodal analgesic in a TKA fast-track protocol. The study evaluated 95 patients on SSTS (SSTS group) and 87 on cFNB (cFNB/control group) and collected data on numeric rating scores for pain from day 1-3 after surgery (T1, T2, T3), both at rest (NRS) and during movement (mNRS), patient's ability to walk, need for supplementary analgesia (rescue dose), occurrence of adverse effects, length of hospital stay, and usability rating for SSTS by both patients and hospital staff. NRS at rest was lower in the cFNB than in the SSTS group for all 3 days after surgery, whereas mNRS scores were lower in the SSTS group at all time points measured. Adverse effects were significantly fewer among patients of the SSTS group (6% patients) than those of the cFNB (74% patients) (p < 0.001). Rescue doses were needed by 5% of SSTS patients vs 60% of cFNB. The fewer adverse events and lower pain scores for the SSTS group were associated to a notably better ability to ambulate, with all patients (100%) of the SSTS group being able to stand and walk for 10 m from T1 on; patients in the cFNB group showed a slower recovery with only 40% being able to stand and walk on T1, 70% on T2 and 85% on T3. All patients of the SSTS group had a length of stay of 4 days (day of surgery plus 3 after) as foreseen by the fast track protocol, in comparison only 36% of cFNB. Lastly, patient and nursing staff judged SSTS easy to use. Our experience suggests that SSTS is a valuable strategy for routine postoperative analgesia following TKA in the context of a multimodal analgesic approach within the fast-track setting.
NASA Astrophysics Data System (ADS)
Fetita, Catalin; Kirov, Boris; Jaramillo, Alfonso; Lefevre, Christophe
2012-03-01
With the accumulation of knowledge for the intimate molecular mechanisms governing the processes inside the living cells in the later years, the ability to characterize the performance of elementary genetic circuits and parts at the single-cell level is becoming of crucial importance. Biological science is arriving to the point where it can develop hypothesis for the action of each molecule participating in the biochemical reactions and need proper techniques to test those hypothesis. Microfluidics is emerging as the technology that combined with high-magnification microscopy will allow for the long-term single-cell level observation of bacterial physiology. In this study we design, build and characterize the gene dynamics of genetic circuits as one of the basic parts governing programmed cell behavior. We use E. coli as model organism and grow it in microfluidics chips, which we observe with epifluorescence microscopy. One of the most invaluable segments of this technology is the consequent image processing, since it allows for the automated analysis of vast amount of single-cell observation and the fast and easy derivation of conclusions based on that data. Specifically, we are interested in promoter activity as function of time. We expect it to be oscillatory and for that we use GFP (green fluorescent protein) as a reporter in our genetic circuits. In this paper, an automated framework for single-cell tracking in phase-contrast microscopy is developed, combining 2D segmentation of cell time frames and graph-based reconstruction of their spatiotemporal evolution with fast tracking of the associated fluorescence signal. The results obtained on the investigated biological database are presented and discussed.
NASA Astrophysics Data System (ADS)
Furtado, H.; Gendrin, C.; Spoerk, J.; Steiner, E.; Underwood, T.; Kuenzler, T.; Georg, D.; Birkfellner, W.
2016-03-01
Radiotherapy treatments have changed at a tremendously rapid pace. Dose delivered to the tumor has escalated while organs at risk (OARs) are better spared. The impact of moving tumors during dose delivery has become higher due to very steep dose gradients. Intra-fractional tumor motion has to be managed adequately to reduce errors in dose delivery. For tumors with large motion such as tumors in the lung, tracking is an approach that can reduce position uncertainty. Tumor tracking approaches range from purely image intensity based techniques to motion estimation based on surrogate tracking. Research efforts are often based on custom designed software platforms which take too much time and effort to develop. To address this challenge we have developed an open software platform especially focusing on tumor motion management. FLIRT is a freely available open-source software platform. The core method for tumor tracking is purely intensity based 2D/3D registration. The platform is written in C++ using the Qt framework for the user interface. The performance critical methods are implemented on the graphics processor using the CUDA extension. One registration can be as fast as 90ms (11Hz). This is suitable to track tumors moving due to respiration (~0.3Hz) or heartbeat (~1Hz). Apart from focusing on high performance, the platform is designed to be flexible and easy to use. Current use cases range from tracking feasibility studies, patient positioning and method validation. Such a framework has the potential of enabling the research community to rapidly perform patient studies or try new methods.
NASA Astrophysics Data System (ADS)
King, Michael Joseph
Instrumentation development is essential to the advancement and success of homeland security systems. Active interrogation techniques that scan luggage and cargo containers for shielded special nuclear materials or explosives hold great potential in halting further terrorist attacks. The development of more economical, compact and efficient source and radiation detection devices will facilitate scanning of all containers and luggage while maintaining high-throughput and low-false alarms Innovative ion sources were developed for two novel, specialized neutron generating devices and initial generator tests were performed. In addition, a low-energy acceleration gamma generator was developed and its performance characterized. Finally, an organic semiconductor was investigated for direct fast neutron detection. A main part of the thesis work was the development of ion sources, crucial components of the neutron/gamma generator development. The use of an externally-driven radio-frequency antenna allows the ion source to generate high beam currents with high, mono-atomic species fractions while maintaining low operating pressures, advantageous parameters for neutron generators. A dual "S" shaped induction antenna was developed to satisfy the high current and large extraction area requirements of the high-intensity neutron generator. The dual antenna arrangement generated a suitable current density of 28 mA/cm2 at practical RF power levels. The stringent requirements of the Pulsed Fast Neutron Transmission Spectroscopy neutron generator necessitated the development of a specialized ten window ion source of toroidal shape with a narrow neutron production target at its center. An innovative ten antenna arrangement with parallel capacitors was developed for driving the multi-antenna arrangement and uniform coupling of RF power to all ten antennas was achieved. To address the desire for low-impact, low-radiation dose active interrogation systems, research was performed on mono-energetic gamma generators that operate at low-acceleration energies and leverage neutron generator technologies. The dissertation focused on the experimental characterization of the generator performance and involved MCNPX simulations to evaluate and analyze the experimental results. The emission of the 11.7 MeV gamma-rays was observed to be slightly anisotropic and the gamma yield was measured to be 2.0*105 gamma/s-mA. The lanthanum hexaboride target suffered beam damage from a high power density beam; however, this may be overcome by sweeping the beam across a larger target area. The efficient detection of fast neutrons is vital to active interrogation techniques for the detection of both SNM and explosives. Novel organic semiconductors are air-stable, low-cost materials that demonstrate direct electronic particle detection. As part of the development of a pi-conjugated organic polymer for fast neutron detection, charge generation and collection properties were investigated. By devising a dual, thin-film detector test arrangement, charge collection was measured for high energy protons traversing the dual detector arrangement that allowed the creation of variable track lengths by tilting the detector. The results demonstrated that an increase in track length resulted in a decreased signal collection. This can be understood by assuming charge carrier transport along the track instead of along the field lines, which was made possible by the filling of traps. However, this charge collection mechanism may be insufficient to generate a useful signal. This dissertation has explored the viability of a new generation of radiation sources and detectors, where the newly developed ion source technologies and prototype generators will further enhance the capabilities of existing threat detection systems and promote the development of cutting-edge detection technologies.
Surveillance of Space - Optimal Use of Complementary Sensors for Maximum Efficiency
2006-04-01
as track - before - detect [4] have been shown to allow improved sensitivity. This technique employs fast running algorithms and computing power to pre...Multifunction Radar” IEEE Signal Processing Magazine, January 2006. [4] Wallace W R “The Use of Track - Before - Detect in Pulse-Doppler Radar” IEE 490, Radar
Leadership in Australian Rural Schools: Bush Track, Fast Track
ERIC Educational Resources Information Center
Graham, Lorraine; Paterson, David; Miller, Judith
2008-01-01
Due to the difficulties inherent in staffing rural schools it is increasingly common for beginning teachers to fill school leadership roles early in their careers. The accelerated progression of some teachers impacts on the overall nature of leadership in rural schools and creates unique pathways, generally different from those available to…
Why Graduate Students Reject the Fast Track
ERIC Educational Resources Information Center
Mason, Mary Ann; Goulden, Marc; Frasch, Karie
2009-01-01
The authors recently completed an unparalleled survey, with more than eight thousand doctoral student respondents across the University of California system, and what they heard is worrisome: major research universities may be losing some of the most talented tenure-track academics before they even arrive. In the eyes of many doctoral students,…
Fast regional readout CMOS Image Sensor for dynamic MLC tracking
NASA Astrophysics Data System (ADS)
Zin, H.; Harris, E.; Osmond, J.; Evans, P.
2014-03-01
Advanced radiotherapy techniques such as volumetric modulated arc therapy (VMAT) require verification of the complex beam delivery including tracking of multileaf collimators (MLC) and monitoring the dose rate. This work explores the feasibility of a prototype Complementary metal-oxide semiconductor Image Sensor (CIS) for tracking these complex treatments by utilising fast, region of interest (ROI) read out functionality. An automatic edge tracking algorithm was used to locate the MLC leaves edges moving at various speeds (from a moving triangle field shape) and imaged with various sensor frame rates. The CIS demonstrates successful edge detection of the dynamic MLC motion within accuracy of 1.0 mm. This demonstrates the feasibility of the sensor to verify treatment delivery involving dynamic MLC up to ~400 frames per second (equivalent to the linac pulse rate), which is superior to any current techniques such as using electronic portal imaging devices (EPID). CIS provides the basis to an essential real-time verification tool, useful in accessing accurate delivery of complex high energy radiation to the tumour and ultimately to achieve better cure rates for cancer patients.
How Does the Fast Track Intervention Prevent Adverse Outcomes in Young Adulthood?
Sorensen, Lucy C.; Dodge, Kenneth A.
2015-01-01
Numerous studies have shown that childhood interventions can foster improved outcomes in adulthood. Less well understood is precisely how – that is, through which developmental pathways – these interventions work. This study assesses mechanisms by which the Fast Track project (n=891), a randomized intervention in the early 1990s for high-risk children in four communities (Durham, NC; Nashville, TN; rural PA; and Seattle, WA), reduced delinquency, arrests, and health and mental health service utilization in adolescence through young adulthood (ages 12–20). A decomposition of treatment effects indicates that about a third of Fast Track’s impact on later crime outcomes can be accounted for by improvements in social and self-regulation skills during childhood (ages 6–11), such as prosocial behavior, emotion regulation and problem solving. These skills proved less valuable for the prevention of mental and physical health problems. PMID:26670938
The research on the mean shift algorithm for target tracking
NASA Astrophysics Data System (ADS)
CAO, Honghong
2017-06-01
The traditional mean shift algorithm for target tracking is effective and high real-time, but there still are some shortcomings. The traditional mean shift algorithm is easy to fall into local optimum in the tracking process, the effectiveness of the method is weak when the object is moving fast. And the size of the tracking window never changes, the method will fail when the size of the moving object changes, as a result, we come up with a new method. We use particle swarm optimization algorithm to optimize the mean shift algorithm for target tracking, Meanwhile, SIFT (scale-invariant feature transform) and affine transformation make the size of tracking window adaptive. At last, we evaluate the method by comparing experiments. Experimental result indicates that the proposed method can effectively track the object and the size of the tracking window changes.
Neural network fusion capabilities for efficient implementation of tracking algorithms
NASA Astrophysics Data System (ADS)
Sundareshan, Malur K.; Amoozegar, Farid
1997-03-01
The ability to efficiently fuse information of different forms to facilitate intelligent decision making is one of the major capabilities of trained multilayer neural networks that is now being recognized. While development of innovative adaptive control algorithms for nonlinear dynamical plants that attempt to exploit these capabilities seems to be more popular, a corresponding development of nonlinear estimation algorithms using these approaches, particularly for application in target surveillance and guidance operations, has not received similar attention. We describe the capabilities and functionality of neural network algorithms for data fusion and implementation of tracking filters. To discuss details and to serve as a vehicle for quantitative performance evaluations, the illustrative case of estimating the position and velocity of surveillance targets is considered. Efficient target- tracking algorithms that can utilize data from a host of sensing modalities and are capable of reliably tracking even uncooperative targets executing fast and complex maneuvers are of interest in a number of applications. The primary motivation for employing neural networks in these applications comes from the efficiency with which more features extracted from different sensor measurements can be utilized as inputs for estimating target maneuvers. A system architecture that efficiently integrates the fusion capabilities of a trained multilayer neural net with the tracking performance of a Kalman filter is described. The innovation lies in the way the fusion of multisensor data is accomplished to facilitate improved estimation without increasing the computational complexity of the dynamical state estimator itself.
SALUTE Grid Application using Message-Oriented Middleware
NASA Astrophysics Data System (ADS)
Atanassov, E.; Dimitrov, D. Sl.; Gurov, T.
2009-10-01
Stochastic ALgorithms for Ultra-fast Transport in sEmiconductors (SALUTE) is a grid application developed for solving various computationally intensive problems which describe ultra-fast carrier transport in semiconductors. SALUTE studies memory and quantum effects during the relaxation process due to electronphonon interaction in one-band semiconductors or quantum wires. Formally, SALUTE integrates a set of novel Monte Carlo, quasi-Monte Carlo and hybrid algorithms for solving various computationally intensive problems which describe the femtosecond relaxation process of optically excited carriers in one-band semiconductors or quantum wires. In this paper we present application-specific job submission and reservation management tool named a Job Track Server (JTS). It is developed using Message-Oriented middleware to implement robust, versatile job submission and tracing mechanism, which can be tailored to application specific failover and quality of service requirements. Experience from using the JTS for submission of SALUTE jobs is presented.
1 Hz fast-heating fusion driver HAMA pumped by a 10 J green diode-pumped solid-state laser
NASA Astrophysics Data System (ADS)
Mori, Y.; Sekine, T.; Komeda, O.; Nakayama, S.; Ishii, K.; Hanayama, R.; Fujita, K.; Okihara, S.; Satoh, N.; Kurita, T.; Kawashima, T.; Kan, H.; Nakamura, N.; Kondo, T.; Fujine, M.; Azuma, H.; Hioki, T.; Kakeno, M.; Motohiro, T.; Nishimura, Y.; Sunahara, A.; Sentoku, Y.; Kitagawa, Y.
2013-07-01
A Ti : sapphire laser HAMA pumped by a diode-pumped solid-state laser (DPSSL) is developed to enable a high-repetitive inertial confinement fusion (ICF) experiment to be conducted. To demonstrate a counter-irradiation fast-heating fusion scheme, a 3.8 J, 0.4 ns amplified chirped pulse is divided into four beams: two counter-irradiate a target with intensities of 6 × 1013 W cm-2, and the remaining two are pulse-compressed to 110 fs for heating the imploded target with intensities of 2 × 1017 W cm-2. HAMA contributed to the first demonstration by showing that a 10 J class DPSSL is adaptable to ICF experiments and succeeded in DD neutron generation in the repetition mode. Based on HAMA, we can design and develop an integrated repetitive ICF experiment machine by including target injection and tracking.
Scalable Track Detection in SAR CCD Images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chow, James G; Quach, Tu-Thach
Existing methods to detect vehicle tracks in coherent change detection images, a product of combining two synthetic aperture radar images ta ken at different times of the same scene, rely on simple, fast models to label track pixels. These models, however, are often too simple to capture natural track features such as continuity and parallelism. We present a simple convolutional network architecture consisting of a series of 3-by-3 convolutions to detect tracks. The network is trained end-to-end to learn natural track features entirely from data. The network is computationally efficient and improves the F-score on a standard dataset to 0.988,more » up fr om 0.907 obtained by the current state-of-the-art method.« less
Dodge, Kenneth A.; Godwin, Jennifer
2013-01-01
In the study reported here, we tested the hypothesis that the Fast Track preventive intervention’s positive impact on antisocial behavior in adolescence is mediated by its impact on social-cognitive processes during elementary school. Fast Track is the largest and longest federally funded preventive intervention trial for children showing aggressive behavior at an early age. Participants were 891 high-risk kindergarten children (69% male, 31% female; 49% ethnic minority, 51% ethnic majority) who were randomly assigned to an intervention or a control group by school cluster. Multiyear intervention addressed social-cognitive processes through social-skill training groups, parent groups, classroom curricula, peer coaching, and tutoring. Assigning children to the intervention decreased their mean antisocial-behavior score after Grade 9 by 0.16 standardized units (p < .01). Structural equation models indicated that 27% of the intervention’s impact on antisocial behavior was mediated by its impact on three social-cognitive processes: reducing hostile-attribution biases, increasing competent response generation to social problems, and devaluing aggression. These findings support a model of antisocial behavioral development mediated by social-cognitive processes, and they guide prevention planners to focus on these processes. PMID:23406610
Particle displacement tracking applied to air flows
NASA Technical Reports Server (NTRS)
Wernet, Mark P.
1991-01-01
Electronic Particle Image Velocimeter (PIV) techniques offer many advantages over conventional photographic PIV methods such as fast turn around times and simplified data reduction. A new all electronic PIV technique was developed which can measure high speed gas velocities. The Particle Displacement Tracking (PDT) technique employs a single cw laser, small seed particles (1 micron), and a single intensified, gated CCD array frame camera to provide a simple and fast method of obtaining two-dimensional velocity vector maps with unambiguous direction determination. Use of a single CCD camera eliminates registration difficulties encountered when multiple cameras are used to obtain velocity magnitude and direction information. An 80386 PC equipped with a large memory buffer frame-grabber board provides all of the data acquisition and data reduction operations. No array processors of other numerical processing hardware are required. Full video resolution (640x480 pixel) is maintained in the acquired images, providing high resolution video frames of the recorded particle images. The time between data acquisition to display of the velocity vector map is less than 40 sec. The new electronic PDT technique is demonstrated on an air nozzle flow with velocities less than 150 m/s.
Should the Air Force Establish a Formalized Mentoring Program
1990-05-01
typically senior members of an organization who take an active interest in the development and career success of a Junior member, called a protege...34fast track" recruits on career success matters. Examples are the Jewell Company, Bell Labs, and some departments of the U.S. Government. Senior...were selected because of their demonstrated career success . The AWC and ACSC students come from the top 5% and 15% of the Air Force respectively, aind
The MONDO project: A secondary neutron tracker detector for particle therapy
NASA Astrophysics Data System (ADS)
Valle, S. M.; Battistoni, G.; Patera, V.; Pinci, D.; Sarti, A.; Sciubba, A.; Spiriti, E.; Marafini, M.
2017-02-01
During Particle Therapy treatments the patient irradiation produces, among different types of secondary radiation, an abundant flux of neutrons that can release a significant dose far away from the tumour region. A precise measurement of their flux, energy and angle distributions is eagerly needed in order to improve the Treatment Planning Systems software and to properly take into account the risk of late complications in the whole body. The technical challenges posed by a neutron detector aiming for high detection efficiency and good backtracking precision will be addressed within the MONDO project, whose main goal is to develop a tracking detector targeting fast and ultra-fast secondary neutrons. The neutron tracking principle is based on the reconstruction of two consequent elastic scattering interactions of a neutron with a target material. Reconstructing the recoiling protons it is hence possible to measure the energy and incoming direction of the neutron. Plastic scintillators will be used as scattering and detection media: the tracker is being developed as a matrix of squared scintillating fibres of 250 μm side. The light produced and collected in fibres will be amplified using a triple GEM-based image intensifier and acquired using CMOS Single Photon Avalanche Diode arrays. Using therapeutic beams, the principal detector goal will be the measurement of the neutron production yields, as a function of production angle and energy.
Experience with "Fast track" postoperative care after deep brain stimulation surgery.
Martín, Nuria; Valero, Ricard; Hurtado, Paola; Gracia, Isabel; Fernández, Carla; Rumià, Jordi; Valldeoriola, Francesc; Carrero, Enrique J; Tercero, Francisco Javier; de Riva, Nicolás; Fàbregas, Neus
A 24-h-stay in the post-anesthesia care unit (PACU) is a common postoperative procedure after deep brain stimulation surgery (DBS). We evaluated the impact of a fast-track (FT) postoperative care protocol. An analysis was performed on all patients who underwent DBS in 2 periods: 2006, overnight monitored care (OMC group), and 2007-2013, FT care (FT group). The study included 19 patients in OMC and 95 patients in FT. Intraoperative complications occurred in 26.3% patients in OMC vs. 35.8% in FT. Post-operatively, one patient in OMC developed hemiparesis, and agitation in 2 patients. In FT, two patients with intraoperative hemiparesis were transferred to the ICU. While on the ward, 3 patients from the FT developed hemiparesis, two of them 48h after the procedure. Thirty eight percent of FT had an MRI scan, while the remaining 62% and all patients of OMC had a CT-scan performed on their transfer to the ward. One patient in OMC had a subthalamic hematoma. Two patients in FT had a pallidal hematoma, and 3 a bleeding along the electrode. A FT discharge protocol is a safe postoperative care after DBS. There are a small percentage of complications after DBS, which mainly occur within the first 6h. Copyright © 2016 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.
Søborg, Christian; Mølbak, Kåre; Doherty, T Mark; Ulleryd, Peter; Brooks, Tim; Coenen, Claudine; van der Zeijst, Ben
2009-05-26
Preparing populations for health threats, including threats from new or re-emerging infectious diseases is recognised as an important public health priority. The development, production and application of emergency vaccinations are the important measures against such threats. Vaccines are cost-effective tools to prevent disease, and emergency vaccines may be the only means to prevent a true disaster for global society in the event of a new pandemic with potential to cause morbidity and mortality comparable to the Spanish flu, the polio epidemics in the 1950s, or the SARS outbreak in 2003 if its spread had not been contained in time. Given the early recognition of a new threat, and given the advances of biotechnology, vaccinology and information systems, it is not an unrealistic goal to have promising prototype vaccine candidates available in a short time span following the identification of a new infectious agent; this is based on the assumption that the emerging infection is followed by natural immunity. However, major bottlenecks for the deployment of emergency vaccine are lack of established systems for fast-track regulatory approval of such candidates and limited international vaccine production capacity. In the present discussion paper, we propose mechanisms to facilitate development of emergency vaccines in Europe by focusing on public-private scientific partnerships, fast-track approval of emergency vaccine by regulatory agencies and proposing incentives for emergency vaccine production in private vaccine companies.
Is "Teach for All" Knocking on Your Door?
ERIC Educational Resources Information Center
Price, Anne; McConney, Andrew
2013-01-01
Over the past few decades there has been a rapid expansion in alternative "fast track" routes for teacher preparation. Among the most aggressive of these are Teach for All (TFA) schemes characterized not only by their ultra fast entry to teaching (6-7 week course) but also by their underlying philosophy that the so called…
The High-Potential Fast-Flying Achiever: Themes from the English Language Literature 1976-1995.
ERIC Educational Resources Information Center
Altman, Yochanan
1997-01-01
Review of business management literature from the United States, United Kingdom, and Canada identified the following: the images of high flyer, fast track, and high achiever; the meaning of success; emphasis on performance; corporate rites of passage; and opportunities for women to be high flyers. (SK)
An efficient and accurate 3D displacements tracking strategy for digital volume correlation
NASA Astrophysics Data System (ADS)
Pan, Bing; Wang, Bo; Wu, Dafang; Lubineau, Gilles
2014-07-01
Owing to its inherent computational complexity, practical implementation of digital volume correlation (DVC) for internal displacement and strain mapping faces important challenges in improving its computational efficiency. In this work, an efficient and accurate 3D displacement tracking strategy is proposed for fast DVC calculation. The efficiency advantage is achieved by using three improvements. First, to eliminate the need of updating Hessian matrix in each iteration, an efficient 3D inverse compositional Gauss-Newton (3D IC-GN) algorithm is introduced to replace existing forward additive algorithms for accurate sub-voxel displacement registration. Second, to ensure the 3D IC-GN algorithm that converges accurately and rapidly and avoid time-consuming integer-voxel displacement searching, a generalized reliability-guided displacement tracking strategy is designed to transfer accurate and complete initial guess of deformation for each calculation point from its computed neighbors. Third, to avoid the repeated computation of sub-voxel intensity interpolation coefficients, an interpolation coefficient lookup table is established for tricubic interpolation. The computational complexity of the proposed fast DVC and the existing typical DVC algorithms are first analyzed quantitatively according to necessary arithmetic operations. Then, numerical tests are performed to verify the performance of the fast DVC algorithm in terms of measurement accuracy and computational efficiency. The experimental results indicate that, compared with the existing DVC algorithm, the presented fast DVC algorithm produces similar precision and slightly higher accuracy at a substantially reduced computational cost.
Human tracking in thermal images using adaptive particle filters with online random forest learning
NASA Astrophysics Data System (ADS)
Ko, Byoung Chul; Kwak, Joon-Young; Nam, Jae-Yeal
2013-11-01
This paper presents a fast and robust human tracking method to use in a moving long-wave infrared thermal camera under poor illumination with the existence of shadows and cluttered backgrounds. To improve the human tracking performance while minimizing the computation time, this study proposes an online learning of classifiers based on particle filters and combination of a local intensity distribution (LID) with oriented center-symmetric local binary patterns (OCS-LBP). Specifically, we design a real-time random forest (RF), which is the ensemble of decision trees for confidence estimation, and confidences of the RF are converted into a likelihood function of the target state. First, the target model is selected by the user and particles are sampled. Then, RFs are generated using the positive and negative examples with LID and OCS-LBP features by online learning. The learned RF classifiers are used to detect the most likely target position in the subsequent frame in the next stage. Then, the RFs are learned again by means of fast retraining with the tracked object and background appearance in the new frame. The proposed algorithm is successfully applied to various thermal videos as tests and its tracking performance is better than those of other methods.
A binary link tracker for the BaBar level 1 trigger system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berenyi, A.; Chen, H.K.; Dao, K.
1999-08-01
The BaBar detector at PEP-II will operate in a high-luminosity e{sup +}e{sup {minus}} collider environment near the {Upsilon}(4S) resonance with the primary goal of studying CP violation in the B meson system. In this environment, typical physics events of interest involve multiple charged particles. These events are identified by counting these tracks in a fast first level (Level 1) trigger system, by reconstructing the tracks in real time. For this purpose, a Binary Link Tracker Module (BLTM) was designed and fabricated for the BaBar Level 1 Drift Chamber trigger system. The BLTM is responsible for linking track segments, constructed bymore » the Track Segment Finder Modules (TSFM), into complete tracks. A single BLTM module processes a 360 MBytes/s stream of segment hit data, corresponding to information from the entire Drift Chamber, and implements a fast and robust algorithm that tolerates high hit occupancies as well as local inefficiencies of the Drift Chamber. The algorithms and the necessary control logic of the BLTM were implemented in Field Programmable Gate Arrays (FPGAs), using the VHDL hardware description language. The finished 9U x 400 mm Euro-format board contains roughly 75,000 gates of programmable logic or about 10,000 lines of VHDL code synthesized into five FPGAs.« less
Blue phase-change recording at high data densities and data rates
NASA Astrophysics Data System (ADS)
Dekker, Martijn K.; Pfeffer, Nicola; Kuijper, Maarten; Ubbens, Igolt P.; Coene, Wim M. J.; Meinders, E. R.; Borg, Herman J.
2000-09-01
For the DVR system with the use of a blue laser diode (wavelength 405 nm) we developed (12 cm) discs with a total capacity of 22.4 GB. The land/groove track pitch is 0.30 micrometers and the channel bit length is 87 nm. The DVR system uses a d equals 1 code. These phase change discs can be recorded at continuous angular velocity at a maximum of 50 Mbps user data rate (including all format and ECC overhead) and meet the system specifications. Fast growth determined phase change materials (FGM) are used for the active layer. In order to apply these FGM discs at small track pitch special attention has been paid to the issue of thermal cross-write. Finally routes towards higher capacities such as advanced bit detection schemes and the use of a smaller track pitch are considered. These show the feasibility in the near future of at least 26.0 GB on a disc for the DVR system with a blue laser diode.
Intracellular microrheology of motile Amoeba proteus.
Rogers, Salman S; Waigh, Thomas A; Lu, Jian R
2008-04-15
The motility of Amoeba proteus was examined using the technique of passive particle tracking microrheology, with the aid of newly developed particle tracking software, a fast digital camera, and an optical microscope. We tracked large numbers of endogeneous particles in the amoebae, which displayed subdiffusive motion at short timescales, corresponding to thermal motion in a viscoelastic medium, and superdiffusive motion at long timescales due to the convection of the cytoplasm. Subdiffusive motion was characterized by a rheological scaling exponent of 3/4 in the cortex, indicative of the semiflexible dynamics of the actin fibers. We observed shear-thinning in the flowing endoplasm, where exponents increased with increasing flow rate; i.e., the endoplasm became more fluid-like. The rheology of the cortex is found to be isotropic, reflecting an isotropic actin gel. A clear difference was seen between cortical and endoplasmic layers in terms of both viscoelasticity and flow velocity, where the profile of the latter is close to a Poiseuille flow for a Newtonian fluid.
Intracellular Microrheology of Motile Amoeba proteus
Rogers, Salman S.; Waigh, Thomas A.; Lu, Jian R.
2008-01-01
The motility of Amoeba proteus was examined using the technique of passive particle tracking microrheology, with the aid of newly developed particle tracking software, a fast digital camera, and an optical microscope. We tracked large numbers of endogeneous particles in the amoebae, which displayed subdiffusive motion at short timescales, corresponding to thermal motion in a viscoelastic medium, and superdiffusive motion at long timescales due to the convection of the cytoplasm. Subdiffusive motion was characterized by a rheological scaling exponent of 3/4 in the cortex, indicative of the semiflexible dynamics of the actin fibers. We observed shear-thinning in the flowing endoplasm, where exponents increased with increasing flow rate; i.e., the endoplasm became more fluid-like. The rheology of the cortex is found to be isotropic, reflecting an isotropic actin gel. A clear difference was seen between cortical and endoplasmic layers in terms of both viscoelasticity and flow velocity, where the profile of the latter is close to a Poiseuille flow for a Newtonian fluid. PMID:18192370
Intracellular Microrheology of Motile Amoeba proteus
NASA Astrophysics Data System (ADS)
Rogers, S.; Waigh, T.; Lu, J.
2008-04-01
The motility of motile Amoeba proteus was examined using the technique of passive particle tracking microrheology, with the aid of newly-developed particle tracking software, a fast digital camera and an optical microscope. We tracked large numbers of endogeneous particles in the amoebae, which displayed subdiffusive motion at short time scales, corresponding to thermal motion in a viscoelastic medium, and superdiffusive motion at long time scales due to the convection of the cytoplasm. Subdiffusive motion was characterised by a rheological scaling exponent of 3/4 in the cortex, indicative of the semiflexible dynamics of the actin fibres. We observed shear-thinning in the flowing endoplasm, where exponents increased with increasing flow rate; i.e. the endoplasm became more fluid-like. The rheology of the cortex is found to be isotropic, reflecting an isotropic actin gel. A clear difference was seen between cortical and endoplasmic layers in terms of both viscoelasticity and flow velocity, where the profile of the latter is close to a Poiseuille flow for a Newtonian fluid.
Zhang, Kaihua; Zhang, Lei; Yang, Ming-Hsuan
2014-10-01
It is a challenging task to develop effective and efficient appearance models for robust object tracking due to factors such as pose variation, illumination change, occlusion, and motion blur. Existing online tracking algorithms often update models with samples from observations in recent frames. Despite much success has been demonstrated, numerous issues remain to be addressed. First, while these adaptive appearance models are data-dependent, there does not exist sufficient amount of data for online algorithms to learn at the outset. Second, online tracking algorithms often encounter the drift problems. As a result of self-taught learning, misaligned samples are likely to be added and degrade the appearance models. In this paper, we propose a simple yet effective and efficient tracking algorithm with an appearance model based on features extracted from a multiscale image feature space with data-independent basis. The proposed appearance model employs non-adaptive random projections that preserve the structure of the image feature space of objects. A very sparse measurement matrix is constructed to efficiently extract the features for the appearance model. We compress sample images of the foreground target and the background using the same sparse measurement matrix. The tracking task is formulated as a binary classification via a naive Bayes classifier with online update in the compressed domain. A coarse-to-fine search strategy is adopted to further reduce the computational complexity in the detection procedure. The proposed compressive tracking algorithm runs in real-time and performs favorably against state-of-the-art methods on challenging sequences in terms of efficiency, accuracy and robustness.
Parameterization-based tracking for the P2 experiment
NASA Astrophysics Data System (ADS)
Sorokin, Iurii
2017-08-01
The P2 experiment in Mainz aims to determine the weak mixing angle θW at low momentum transfer by measuring the parity-violating asymmetry of elastic electronproton scattering. In order to achieve the intended precision of Δ(sin2 θW)/sin2θW = 0:13% within the planned 10 000 hours of running the experiment has to operate at the rate of 1011 detected electrons per second. Although it is not required to measure the kinematic parameters of each individual electron, every attempt is made to achieve the highest possible throughput in the track reconstruction chain. In the present work a parameterization-based track reconstruction method is described. It is a variation of track following, where the results of the computation-heavy steps, namely the propagation of a track to the further detector plane, and the fitting, are pre-calculated, and expressed in terms of parametric analytic functions. This makes the algorithm extremely fast, and well-suited for an implementation on an FPGA. The method also takes implicitly into account the actual phase space distribution of the tracks already at the stage of candidate construction. Compared to a simple algorithm, that does not use such information, this allows reducing the combinatorial background by many orders of magnitude, down to O(1) background candidate per one signal track. The method is developed specifically for the P2 experiment in Mainz, and the presented implementation is tightly coupled to the experimental conditions.
Kim, Kwangtaek; Kim, Joongrock; Choi, Jaesung; Kim, Junghyun; Lee, Sangyoun
2015-01-01
Vision-based hand gesture interactions are natural and intuitive when interacting with computers, since we naturally exploit gestures to communicate with other people. However, it is agreed that users suffer from discomfort and fatigue when using gesture-controlled interfaces, due to the lack of physical feedback. To solve the problem, we propose a novel complete solution of a hand gesture control system employing immersive tactile feedback to the user's hand. For this goal, we first developed a fast and accurate hand-tracking algorithm with a Kinect sensor using the proposed MLBP (modified local binary pattern) that can efficiently analyze 3D shapes in depth images. The superiority of our tracking method was verified in terms of tracking accuracy and speed by comparing with existing methods, Natural Interaction Technology for End-user (NITE), 3D Hand Tracker and CamShift. As the second step, a new tactile feedback technology with a piezoelectric actuator has been developed and integrated into the developed hand tracking algorithm, including the DTW (dynamic time warping) gesture recognition algorithm for a complete solution of an immersive gesture control system. The quantitative and qualitative evaluations of the integrated system were conducted with human subjects, and the results demonstrate that our gesture control with tactile feedback is a promising technology compared to a vision-based gesture control system that has typically no feedback for the user's gesture inputs. Our study provides researchers and designers with informative guidelines to develop more natural gesture control systems or immersive user interfaces with haptic feedback. PMID:25580901
Kim, Kwangtaek; Kim, Joongrock; Choi, Jaesung; Kim, Junghyun; Lee, Sangyoun
2015-01-08
Vision-based hand gesture interactions are natural and intuitive when interacting with computers, since we naturally exploit gestures to communicate with other people. However, it is agreed that users suffer from discomfort and fatigue when using gesture-controlled interfaces, due to the lack of physical feedback. To solve the problem, we propose a novel complete solution of a hand gesture control system employing immersive tactile feedback to the user's hand. For this goal, we first developed a fast and accurate hand-tracking algorithm with a Kinect sensor using the proposed MLBP (modified local binary pattern) that can efficiently analyze 3D shapes in depth images. The superiority of our tracking method was verified in terms of tracking accuracy and speed by comparing with existing methods, Natural Interaction Technology for End-user (NITE), 3D Hand Tracker and CamShift. As the second step, a new tactile feedback technology with a piezoelectric actuator has been developed and integrated into the developed hand tracking algorithm, including the DTW (dynamic time warping) gesture recognition algorithm for a complete solution of an immersive gesture control system. The quantitative and qualitative evaluations of the integrated system were conducted with human subjects, and the results demonstrate that our gesture control with tactile feedback is a promising technology compared to a vision-based gesture control system that has typically no feedback for the user's gesture inputs. Our study provides researchers and designers with informative guidelines to develop more natural gesture control systems or immersive user interfaces with haptic feedback.
Fast Track, Bush Track: Late Career Female Rural School Leaders Taking the Slow Road
ERIC Educational Resources Information Center
Miller, Judith; Graham, Lorraine; Al-Awiwe, Azhar
2014-01-01
Previous research related to this study explored early career female leaders' experiences in rural school settings, and probed the personal and professional challenges they faced and their motivations to accept formal and informal leadership roles ahead of the usual timeframes (e.g., Graham, Miller & Paterson, 2009). This study set out to…
ERIC Educational Resources Information Center
Howe, Quincy
2006-01-01
In this article, the author relates how a math-assessment software has allowed his school to track the academic progress of its students. The author relates that in the first year that the software was deployed, schoolwide averages in terms of national standing on the math ITBS rose from the 42nd to 59th percentile. In addition, a significant…
A stochastic optimal feedforward and feedback control methodology for superagility
NASA Technical Reports Server (NTRS)
Halyo, Nesim; Direskeneli, Haldun; Taylor, Deborah B.
1992-01-01
A new control design methodology is developed: Stochastic Optimal Feedforward and Feedback Technology (SOFFT). Traditional design techniques optimize a single cost function (which expresses the design objectives) to obtain both the feedforward and feedback control laws. This approach places conflicting demands on the control law such as fast tracking versus noise atttenuation/disturbance rejection. In the SOFFT approach, two cost functions are defined. The feedforward control law is designed to optimize one cost function, the feedback optimizes the other. By separating the design objectives and decoupling the feedforward and feedback design processes, both objectives can be achieved fully. A new measure of command tracking performance, Z-plots, is also developed. By analyzing these plots at off-nominal conditions, the sensitivity or robustness of the system in tracking commands can be predicted. Z-plots provide an important tool for designing robust control systems. The Variable-Gain SOFFT methodology was used to design a flight control system for the F/A-18 aircraft. It is shown that SOFFT can be used to expand the operating regime and provide greater performance (flying/handling qualities) throughout the extended flight regime. This work was performed under the NASA SBIR program. ICS plans to market the software developed as a new module in its commercial CACSD software package: ACET.
NASA Astrophysics Data System (ADS)
Chen, Xiao; Li, Yaan; Yu, Jing; Li, Yuxing
2018-01-01
For fast and more effective implementation of tracking multiple targets in a cluttered environment, we propose a multiple targets tracking (MTT) algorithm called maximum entropy fuzzy c-means clustering joint probabilistic data association that combines fuzzy c-means clustering and the joint probabilistic data association (PDA) algorithm. The algorithm uses the membership value to express the probability of the target originating from measurement. The membership value is obtained through fuzzy c-means clustering objective function optimized by the maximum entropy principle. When considering the effect of the public measurement, we use a correction factor to adjust the association probability matrix to estimate the state of the target. As this algorithm avoids confirmation matrix splitting, it can solve the high computational load problem of the joint PDA algorithm. The results of simulations and analysis conducted for tracking neighbor parallel targets and cross targets in a different density cluttered environment show that the proposed algorithm can realize MTT quickly and efficiently in a cluttered environment. Further, the performance of the proposed algorithm remains constant with increasing process noise variance. The proposed algorithm has the advantages of efficiency and low computational load, which can ensure optimum performance when tracking multiple targets in a dense cluttered environment.
A-Track: A New Approach for Detection of Moving Objects in FITS Images
NASA Astrophysics Data System (ADS)
Kılıç, Yücel; Karapınar, Nurdan; Atay, Tolga; Kaplan, Murat
2016-07-01
Small planet and asteroid observations are important for understanding the origin and evolution of the Solar System. In this work, we have developed a fast and robust pipeline, called A-Track, for detecting asteroids and comets in sequential telescope images. The moving objects are detected using a modified line detection algorithm, called ILDA. We have coded the pipeline in Python 3, where we have made use of various scientific modules in Python to process the FITS images. We tested the code on photometrical data taken by an SI-1100 CCD with a 1-meter telescope at TUBITAK National Observatory, Antalya. The pipeline can be used to analyze large data archives or daily sequential data. The code is hosted on GitHub under the GNU GPL v3 license.
The Long Island Sound Dredged Material Containment Feasibility Study.
1983-02-01
ancilliary businesses, such as sporting goods stores, dockside gasoline dealers, bait and tackle shops, and fast food services would also be negatively...to there is almost always some ex- tached or unable to move fast enough maintain the area’s importance as a change of nutrients and organisms to avoid...basis, authorized depth of 14 feet or less will no longer be maintained by the Corps of (4) Fast -tracking of navigation Engineers. Presently, only 7
Phonological and Orthographic Overlap Effects in Fast and Masked Priming
Frisson, Steven; Bélanger, Nathalie N.; Rayner, Keith
2014-01-01
We investigated how orthographic and phonological information is activated during reading, using a fast priming task, and during single word recognition, using masked priming. Specifically, different types of overlap between prime and target were contrasted: high orthographic and high phonological overlap (track-crack), high orthographic and low phonological overlap (bear-gear), or low orthographic and high phonological overlap (fruit-chute). In addition, we examined whether (orthographic) beginning overlap (swoop-swoon) yielded the same priming pattern as end (rhyme) overlap (track-crack). Prime durations were 32 and 50ms in the fast priming version, and 50ms in the masked priming version, and mode of presentation (prime and target in lower case) was identical. The fast priming experiment showed facilitatory priming effects when both orthography and phonology overlapped, with no apparent differences between beginning and end overlap pairs. Facilitation was also found when prime and target only overlapped orthographically. In contrast, the masked priming experiment showed inhibition for both types of end overlap pairs (with and without phonological overlap), and no difference for begin overlap items. When prime and target only shared principally phonological information, facilitation was only found with a long prime duration in the fast priming experiment, while no differences were found in the masked priming version. These contrasting results suggest that fast priming and masked priming do not necessarily tap into the same type of processing. PMID:24365065
Accuracy analysis for triangulation and tracking based on time-multiplexed structured light.
Wagner, Benjamin; Stüber, Patrick; Wissel, Tobias; Bruder, Ralf; Schweikard, Achim; Ernst, Floris
2014-08-01
The authors' research group is currently developing a new optical head tracking system for intracranial radiosurgery. This tracking system utilizes infrared laser light to measure features of the soft tissue on the patient's forehead. These features are intended to offer highly accurate registration with respect to the rigid skull structure by means of compensating for the soft tissue. In this context, the system also has to be able to quickly generate accurate reconstructions of the skin surface. For this purpose, the authors have developed a laser scanning device which uses time-multiplexed structured light to triangulate surface points. The accuracy of the authors' laser scanning device is analyzed and compared for different triangulation methods. These methods are given by the Linear-Eigen method and a nonlinear least squares method. Since Microsoft's Kinect camera represents an alternative for fast surface reconstruction, the authors' results are also compared to the triangulation accuracy of the Kinect device. Moreover, the authors' laser scanning device was used for tracking of a rigid object to determine how this process is influenced by the remaining triangulation errors. For this experiment, the scanning device was mounted to the end-effector of a robot to be able to calculate a ground truth for the tracking. The analysis of the triangulation accuracy of the authors' laser scanning device revealed a root mean square (RMS) error of 0.16 mm. In comparison, the analysis of the triangulation accuracy of the Kinect device revealed a RMS error of 0.89 mm. It turned out that the remaining triangulation errors only cause small inaccuracies for the tracking of a rigid object. Here, the tracking accuracy was given by a RMS translational error of 0.33 mm and a RMS rotational error of 0.12°. This paper shows that time-multiplexed structured light can be used to generate highly accurate reconstructions of surfaces. Furthermore, the reconstructed point sets can be used for high-accuracy tracking of objects, meeting the strict requirements of intracranial radiosurgery.
KOLAM: a cross-platform architecture for scalable visualization and tracking in wide-area imagery
NASA Astrophysics Data System (ADS)
Fraser, Joshua; Haridas, Anoop; Seetharaman, Guna; Rao, Raghuveer M.; Palaniappan, Kannappan
2013-05-01
KOLAM is an open, cross-platform, interoperable, scalable and extensible framework supporting a novel multi- scale spatiotemporal dual-cache data structure for big data visualization and visual analytics. This paper focuses on the use of KOLAM for target tracking in high-resolution, high throughput wide format video also known as wide-area motion imagery (WAMI). It was originally developed for the interactive visualization of extremely large geospatial imagery of high spatial and spectral resolution. KOLAM is platform, operating system and (graphics) hardware independent, and supports embedded datasets scalable from hundreds of gigabytes to feasibly petabytes in size on clusters, workstations, desktops and mobile computers. In addition to rapid roam, zoom and hyper- jump spatial operations, a large number of simultaneously viewable embedded pyramid layers (also referred to as multiscale or sparse imagery), interactive colormap and histogram enhancement, spherical projection and terrain maps are supported. The KOLAM software architecture was extended to support airborne wide-area motion imagery by organizing spatiotemporal tiles in very large format video frames using a temporal cache of tiled pyramid cached data structures. The current version supports WAMI animation, fast intelligent inspection, trajectory visualization and target tracking (digital tagging); the latter by interfacing with external automatic tracking software. One of the critical needs for working with WAMI is a supervised tracking and visualization tool that allows analysts to digitally tag multiple targets, quickly review and correct tracking results and apply geospatial visual analytic tools on the generated trajectories. One-click manual tracking combined with multiple automated tracking algorithms are available to assist the analyst and increase human effectiveness.
Fast and Adaptive Auto-focusing Microscope
NASA Astrophysics Data System (ADS)
Obara, Takeshi; Igarashi, Yasunobu; Hashimoto, Koichi
Optical microscopes are widely used in biological and medical researches. By using the microscope, we can observe cellular movements including intracellular ions and molecules tagged with fluorescent dyes at a high magnification. However, a freely motile cell easily escapes from a 3D field of view of the typical microscope. Therefore, we propose a novel auto-focusing algorithm and develop a auto-focusing and tracking microscope. XYZ positions of a microscopic stage are feedback controlled to focus and track the cell automatically. A bright-field image is used to estimate a cellular position. XY centroids are used to estimate XY positions of the tracked cell. To estimate Z position, we use a diffraction pattern around the cell membrane. This estimation method is so-called Depth from Diffraction (DFDi). However, this method is not robust for individual differences between cells because the diffraction pattern depends on each cellular shape. Therefore, in this study, we propose a real-time correction of DFDi by using 2D Laplacian of an intracellular area as a goodness of the focus. To evaluate the performance of our developed algorithm and microscope, we auto-focus and track a freely moving paramecium. In this experimental result, the paramecium is auto-focused and kept inside the scope of the microscope during 45s. The evaluated focal error is within 5µm, while a length and a thickness of the paramecium are about 200µm and 50µm, respectively.
Ding, Yu; Li, Chunqiang
2016-01-01
Nanoscale particle tracking in three dimensions is crucial to directly observe dynamics of molecules and nanoparticles in living cells. Here we present a three-dimensional particle tracking method based on temporally focused two-photon excitation. Multiple particles are imaged at 30 frames/s in volume up to 180 × 180 × 100 µm3. The spatial localization precision can reach 50 nm. We demonstrate its capability of tracking fast swimming microbes at speed of ~200 µm/s. Two-photon dual-color tracking is achieved by simultaneously exciting two kinds of fluorescent beads at 800 nm to demonstrate its potential in molecular interaction studies. Our method provides a simple wide-field fluorescence imaging approach for deep multiple-particle tracking. PMID:27867724
NASA Astrophysics Data System (ADS)
Dimiduk, D.; Caylor, M.; Williamson, D.; Larson, L.
1995-01-01
The High Altitude Balloon Experiment demonstration of Acquisition, Tracking, and Pointing (HABE-ATP) is a system built around balloon-borne payload which is carried to a nominal 26-km altitude. The goal is laser tracking thrusting theater and strategic missiles, and then pointing a surrogate laser weapon beam, with performance levels end a timeline traceable to operational laser weapon system requirements. This goal leads to an experiment system design which combines hardware from many technology areas: an optical telescope and IR sensors; an advanced angular inertial reference; a flexible multi-level of actuation digital control system; digital tracking processors which incorporate real-time image analysis and a pulsed, diode-pumped solid state tracking laser. The system components have been selected to meet the overall experiment goals of tracking unmodified boosters at 50- 200 km range. The ATP system on HABE must stabilize and control a relative line of sight between the platform and the unmodified target booster to a 1 microrad accuracy. The angular pointing reference system supports both open loop and closed loop track modes; GPS provides absolute position reference. The control system which positions the line of sight for the ATP system must sequence through accepting a state vector handoff, closed-loop passive IR acquisition, passive IR intermediate fine track, active fine track, and then finally aimpoint determination and maintenance modes. Line of sight stabilization to fine accuracy levels is accomplished by actuating wide bandwidth fast steering mirrors (FSM's). These control loops off-load large-amplitude errors to the outer gimbal in order to remain within the limited angular throw of the FSM's. The SWIR acquisition and MWIR intermediate fine track sensors (both PtSi focal planes) image the signature of the rocket plume. After Hard Body Handover (HBHO), active fine tracking is conducted with a visible focal plane viewing the laser-illuminated target rocket body. The track and fire control performance must be developed to the point that an aimpoint can be selected, maintained, and then track performance scored with a low-power 'surrogate' weapon beam. Extensive instrumentation monitors not only the optical sensors and the video data, but all aspects of each of the experiment subsystems such as the control system, the experiment flight vehicle, and the tracker. Because the system is balloon-borne and recoverable, it is expected to fly many times during its development program.
Status, upgrades, and advances of RTS2: the open source astronomical observatory manager
NASA Astrophysics Data System (ADS)
Kubánek, Petr
2016-07-01
RTS2 is an open source observatory control system. Being developed from early 2000, it continue to receive new features in last two years. RTS2 is a modulat, network-based distributed control system, featuring telescope drivers with advanced tracking and pointing capabilities, fast camera drivers and high level modules for "business logic" of the observatory, connected to a SQL database. Running on all continents of the planet, it accumulated a lot to control parts or full observatory setups.
Decentralized digital adaptive control of robot motion
NASA Technical Reports Server (NTRS)
Tarokh, M.
1990-01-01
A decentralized model reference adaptive scheme is developed for digital control of robot manipulators. The adaptation laws are derived using hyperstability theory, which guarantees asymptotic trajectory tracking despite gross robot parameter variations. The control scheme has a decentralized structure in the sense that each local controller receives only its joint angle measurement to produce its joint torque. The independent joint controllers have simple structures and can be programmed using a very simple and computationally fast algorithm. As a result, the scheme is suitable for real-time motion control.
NASA Astrophysics Data System (ADS)
Huang, Xiaomeng; Hu, Chenqi; Huang, Xing; Chu, Yang; Tseng, Yu-heng; Zhang, Guang Jun; Lin, Yanluan
2018-01-01
Mesoscale convective systems (MCSs) are important components of tropical weather systems and the climate system. Long-term data of MCS are of great significance in weather and climate research. Using long-term (1985-2008) global satellite infrared (IR) data, we developed a novel objective automatic tracking algorithm, which combines a Kalman filter (KF) with the conventional area-overlapping method, to generate a comprehensive MCS dataset. The new algorithm can effectively track small and fast-moving MCSs and thus obtain more realistic and complete tracking results than previous studies. A few examples are provided to illustrate the potential application of the dataset with a focus on the diurnal variations of MCSs over land and ocean regions. We find that the MCSs occurring over land tend to initiate in the afternoon with greater intensity, but the oceanic MCSs are more likely to initiate in the early morning with weaker intensity. A double peak in the maximum spatial coverage is noted over the western Pacific, especially over the southwestern Pacific during the austral summer. Oceanic MCSs also persist for approximately 1 h longer than their continental counterparts.
Non-rigid estimation of cell motion in calcium time-lapse images
NASA Astrophysics Data System (ADS)
Hachi, Siham; Lucumi Moreno, Edinson; Desmet, An-Sofie; Vanden Berghe, Pieter; Fleming, Ronan M. T.
2016-03-01
Calcium imaging is a widely used technique in neuroscience permitting the simultaneous monitoring of electro- physiological activity of hundreds of neurons at single cell resolution. Identification of neuronal activity requires rapid and reliable image analysis techniques, especially when neurons fire and move simultaneously over time. Traditionally, image segmentation is performed to extract individual neurons in the first frame of a calcium sequence. Thereafter, the mean intensity is calculated from the same region of interest in each frame to infer calcium signals. However, when cells move, deform and fire, this segmentation on its own generates artefacts and therefore biased neuronal activity. Therefore, there is a pressing need to develop a more efficient cell tracking technique. We hereby present a novel vision-based cell tracking scheme using a thin-plate spline deformable model. The thin-plate spline warping is based on control points detected using the Fast from Accelerated Segment Test descriptor and tracked using the Lucas-Kanade optical flow. Our method is able to track neurons in calcium time-series, even when there are large changes in intensity, such as during a firing event. The robustness and efficiency of the proposed approach is validated on real calcium time-lapse images of a neuronal population.
Oestergaard, Lisa G; Christensen, Finn B; Nielsen, Claus V; Bünger, Cody E; Fruensgaard, Soeren; Sogaard, Rikke
2013-11-01
Economic evaluation conducted alongside a randomized controlled trial with 1-year follow-up. To examine the cost-effectiveness of initiating rehabilitation 6 weeks after surgery as opposed to 12 weeks after surgery. In a previously reported randomized controlled trial, we assessed the impact of timing of rehabilitation after a lumbar spinal fusion and found that a fast-track strategy led to poorer functional ability. Before making recommendations, it seems relevant to address the societal perspective including return to work, quality of life, and costs. A cost-effectiveness analysis and a cost-utility analysis were conducted. Eighty-two patients undergoing instrumented lumbar spinal fusion due to degenerative disc disease or spondylolisthesis (grade I or II) were randomized to an identical protocol of 4 sessions of group-based rehabilitation and were instructed in home exercises focusing on active stability training. Outcome parameters included functional disability (Oswestry Disability Index) and quality-adjusted life years. Health care and productivity costs were estimated from national registries and reported in euros. Costs and effects were transformed into net benefit. Bootstrapping was used to estimate 95% confidence intervals (95% CI). The fast-track strategy tended to be costlier by €6869 (95% CI, -4640 to 18,378) while at the same time leading to significantly poorer outcomes of functional disability by -9 points (95% CI, -18 to -3) and a tendency for a reduced gain in quality-adjusted life years by -0.04 (95% CI, -0.13 to 0.01). The overall probability for the fast-track strategy being cost-effective does not reach 10% at conventional thresholds for cost-effectiveness. Initiating rehabilitation at 6 weeks as opposed to 12 weeks after surgery is on average more costly and less effective. The uncertainty of this result did not seem to be sensitive to methodological issues, and clinical managements who have already adapted fast-track rehabilitation strategies have reason to reconsider their choice. .
NASA Astrophysics Data System (ADS)
Mirabelli, R.; Battistoni, G.; Giacometti, V.; Patera, V.; Pinci, D.; Sarti, A.; Sciubba, A.; Traini, G.; Marafini, M.
2018-01-01
In Particle Therapy (PT) accelerated charged particles and light ions are used for treating tumors. One of the main limitation to the precision of PT is the emission of secondary particles due to the beam interaction with the patient: secondary emitted neutrons can release a significant dose far from the tumor. Therefore, a precise characterization of their flux, production energy and angle distribution is eagerly needed in order to improve the Treatment Planning Systems (TPS) codes. The principal aim of the MONDO (MOnitor for Neutron Dose in hadrOntherapy) project is the development of a tracking device optimized for the detection of fast and ultra-fast secondary neutrons emitted in PT. The detector consists of a matrix of scintillating square fibres coupled with a CMOS-based readout. Here, we present the characterization of the detector tracker prototype and CMOS-based digital SPAD (Single Photon Avalanche Diode) array sensor tested with protons at the Beam Test Facility (Frascati, Italy) and at the Proton Therapy Centre (Trento, Italy), respectively.
Multi-Robot FastSLAM for Large Domains
2007-03-01
Derr, D. Fox, A.B. Cremers , Integrating global position estimation and position tracking for mobile robots: The dynamic markov localization approach...Intelligence (AAAI), 2000. 53. Andrew J. Davison and David W. Murray. Simultaneous Localization and Map- Building Using Active Vision. IEEE...Wyeth, Michael Milford and David Prasser. A Modified Particle Filter for Simultaneous Robot Localization and Landmark Tracking in an Indoor
Navigators for motion detection during real-time MRI-guided radiotherapy
NASA Astrophysics Data System (ADS)
Stam, Mette K.; Crijns, Sjoerd P. M.; Zonnenberg, Bernard A.; Barendrecht, Maurits M.; van Vulpen, Marco; Lagendijk, Jan J. W.; Raaymakers, Bas W.
2012-11-01
An MRI-linac system provides direct MRI feedback and with that the possibility of adapting radiation treatments to the actual tumour position. This paper addresses the use of fast 1D MRI, pencil-beam navigators, for this feedback. The accuracy of using navigators was determined on a moving phantom. The possibility of organ tracking and breath-hold monitoring based on navigator guidance was shown for the kidney. Navigators are accurate within 0.5 mm and the analysis has a minimal time lag smaller than 30 ms as shown for the phantom measurements. The correlation of 2D kidney images and navigators shows the possibility of complete organ tracking. Furthermore the breath-hold monitoring of the kidney is accurate within 1.5 mm, allowing gated radiotherapy based on navigator feedback. Navigators are a fast and precise method for monitoring and real-time tracking of anatomical landmarks. As such, they provide direct MRI feedback on anatomical changes for more precise radiation delivery.
Joint polarization tracking and channel equalization based on radius-directed linear Kalman filter
NASA Astrophysics Data System (ADS)
Zhang, Qun; Yang, Yanfu; Zhong, Kangping; Liu, Jie; Wu, Xiong; Yao, Yong
2018-01-01
We propose a joint polarization tracking and channel equalization scheme based on radius-directed linear Kalman filter (RD-LKF) by introducing the butterfly finite-impulse-response (FIR) filter in our previously proposed RD-LKF method. Along with the fast polarization tracking, it can also simultaneously compensate the inter-symbol interference (ISI) effects including residual chromatic dispersion and polarization mode dispersion. Compared with the conventional radius-directed equalizer (RDE) algorithm, it is demonstrated experimentally that three times faster convergence speed, one order of magnitude better tracking capability, and better BER performance is obtained in polarization division multiplexing 16 quadrature amplitude modulation system. Besides, the influences of the algorithm parameters on the convergence and the tracking performance are investigated by numerical simulation.
Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hansen, Rune; Ravkilde, Thomas; Worm, Esben Schjødt
2016-05-15
Purpose: Couch and MLC tracking are two promising methods for real-time motion compensation during radiation therapy. So far, couch and MLC tracking experiments have mainly been performed by different research groups, and no direct comparison of couch and MLC tracking of volumetric modulated arc therapy (VMAT) plans has been published. The Varian TrueBeam 2.0 accelerator includes a prototype tracking system with selectable couch or MLC compensation. This study provides a direct comparison of the two tracking types with an otherwise identical setup. Methods: Several experiments were performed to characterize the geometric and dosimetric performance of electromagnetic guided couch and MLCmore » tracking on a TrueBeam accelerator equipped with a Millennium MLC. The tracking system latency was determined without motion prediction as the time lag between sinusoidal target motion and the compensating motion of the couch or MLC as recorded by continuous MV portal imaging. The geometric and dosimetric tracking accuracies were measured in tracking experiments with motion phantoms that reproduced four prostate and four lung tumor trajectories. The geometric tracking error in beam’s eye view was determined as the distance between an embedded gold marker and a circular MLC aperture in continuous MV images. The dosimetric tracking error was quantified as the measured 2%/2 mm gamma failure rate of a low and a high modulation VMAT plan delivered with the eight motion trajectories using a static dose distribution as reference. Results: The MLC tracking latency was approximately 146 ms for all sinusoidal period lengths while the couch tracking latency increased from 187 to 246 ms with decreasing period length due to limitations in the couch acceleration. The mean root-mean-square geometric error was 0.80 mm (couch tracking), 0.52 mm (MLC tracking), and 2.75 mm (no tracking) parallel to the MLC leaves and 0.66 mm (couch), 1.14 mm (MLC), and 2.41 mm (no tracking) perpendicular to the leaves. The motion-induced gamma failure rate was in mean 0.1% (couch tracking), 8.1% (MLC tracking), and 30.4% (no tracking) for prostate motion and 2.9% (couch), 2.4% (MLC), and 41.2% (no tracking) for lung tumor motion. The residual tracking errors were mainly caused by inadequate adaptation to fast lung tumor motion for couch tracking and to prostate motion perpendicular to the MLC leaves for MLC tracking. Conclusions: Couch and MLC tracking markedly improved the geometric and dosimetric accuracies of VMAT delivery. However, the two tracking types have different strengths and weaknesses. While couch tracking can correct perfectly for slowly moving targets such as the prostate, MLC tracking may have considerably larger dose errors for persistent target shift perpendicular to the MLC leaves. Advantages of MLC tracking include faster dynamics with better adaptation to fast moving targets, the avoidance of moving the patient, and the potential to track target rotations and deformations.« less
OPTICAL TRANSCRIBING OSCILLOSCOPE
Kerns, Q.A.
1961-09-26
A device is designed for producing accurate graphed waveforms of very fast electronic pulses. The fast pulse is slowly tracked on a cathode ray tube and a pair of photomultiplier tubes, exposed to the pulse trace, view separate vertical portions thereof at each side of a fixed horizontal reference. Each phototube produces an output signal indicative of vertical movement of the exposed trace, which simultaneous signals are compared in a difference amplifier. The amplifier produces a difference signal which, when applied to the cathode ray tube, maintains the trace on the reference. A graphic recorder receives the amplified difference signal at an x-axis input, while a y-axis input is synchronized with the tracking time of the cathode ray tube and therefore graphs the enlarged waveshape.
Event Management of RFID Data Streams: Fast Moving Consumer Goods Supply Chains
NASA Astrophysics Data System (ADS)
Mo, John P. T.; Li, Xue
Radio Frequency Identification (RFID) is a wireless communication technology that uses radio-frequency waves to transfer information between tagged objects and readers without line of sight. This creates tremendous opportunities for linking real world objects into a world of "Internet of things". Application of RFID to Fast Moving Consumer Goods sector will introduce billions of RFID tags in the world. Almost everything is tagged for tracking and identification purposes. This phenomenon will impose a new challenge not only to the network capacity but also to the scalability of processing of RFID events and data. This chapter uses two national demonstrator projects in Australia as case studies to introduce an event managementframework to process high volume RFID data streams in real time and automatically transform physical RFID observations into business-level events. The model handles various temporal event patterns, both simple and complex, with temporal constraints. The model can be implemented in a data management architecture that allows global RFID item tracking and enables fast, large-scale RFID deployment.
Incident angle dependence of proton response of CR-39 (TS-16) track detector
NASA Technical Reports Server (NTRS)
Oda, K.; Csige, I.; Yamauchi, T.; Miyake, H.; Benton, E. V.
1993-01-01
The proton response of the TS-16 type of CR-39 plastic nuclear track detector has been studied with accelerated and fast neutron induced protons in vacuum and in air. The diameters of etched tracks were measured as a function of etching time and the etch rate ratio and the etch induction layer were determined from the growth curve of the diameter using a variable etch rate ratio model. In the case of the accelerated protons in vacuum an anomalous incident angle dependence of the response is observed.
Rezvani, Alireza; Khalili, Abbas; Mazareie, Alireza; Gandomkar, Majid
2016-07-01
Nowadays, photovoltaic (PV) generation is growing increasingly fast as a renewable energy source. Nevertheless, the drawback of the PV system is its dependence on weather conditions. Therefore, battery energy storage (BES) can be considered to assist for a stable and reliable output from PV generation system for loads and improve the dynamic performance of the whole generation system in grid connected mode. In this paper, a novel topology of intelligent hybrid generation systems with PV and BES in a DC-coupled structure is presented. Each photovoltaic cell has a specific point named maximum power point on its operational curve (i.e. current-voltage or power-voltage curve) in which it can generate maximum power. Irradiance and temperature changes affect these operational curves. Therefore, the nonlinear characteristic of maximum power point to environment has caused to development of different maximum power point tracking techniques. In order to capture the maximum power point (MPP), a hybrid fuzzy-neural maximum power point tracking (MPPT) method is applied in the PV system. Obtained results represent the effectiveness and superiority of the proposed method, and the average tracking efficiency of the hybrid fuzzy-neural is incremented by approximately two percentage points in comparison to the conventional methods. It has the advantages of robustness, fast response and good performance. A detailed mathematical model and a control approach of a three-phase grid-connected intelligent hybrid system have been proposed using Matlab/Simulink. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Fast Track Teacher Education: A Review of the Research Literature on "Teach For All" Schemes
ERIC Educational Resources Information Center
McConney, Andrew; Price, Anne; Woods-McConney, Amanda
2012-01-01
This review of the research literature was commissioned by the New Zealand Post-Primary Teachers Association (PPTA) Te Wehengarua as a means of informing the decision-making of the Association and its members about the Teach For All (TFA) scheme seeking to prepare teachers for New Zealand's schools. The systematic review is about fast track…
ERIC Educational Resources Information Center
Hertrich, Ingo; Dietrich, Susanne; Ackermann, Hermann
2013-01-01
Blind people can learn to understand speech at ultra-high syllable rates (ca. 20 syllables/s), a capability associated with hemodynamic activation of the central-visual system. To further elucidate the neural mechanisms underlying this skill, magnetoencephalographic (MEG) measurements during listening to sentence utterances were cross-correlated…
Getting a College Degree Fast: Testing Out & Other Accredited Short Cuts.
ERIC Educational Resources Information Center
Aber, Joanne
This book, directed especially to individuals over age 30, takes a how-to approach to earning a college degree in the least amount of time for the least amount of money. The book explains how to use fast-track methods such as "testing out," which takes advantage of prior learning, and accredited shortcuts to earn an accelerated degree. The first…
Don’t speak too fast! Processing of fast rate speech in children with specific language impairment
Bedoin, Nathalie; Krifi-Papoz, Sonia; Herbillon, Vania; Caillot-Bascoul, Aurélia; Gonzalez-Monge, Sibylle; Boulenger, Véronique
2018-01-01
Background Perception of speech rhythm requires the auditory system to track temporal envelope fluctuations, which carry syllabic and stress information. Reduced sensitivity to rhythmic acoustic cues has been evidenced in children with Specific Language Impairment (SLI), impeding syllabic parsing and speech decoding. Our study investigated whether these children experience specific difficulties processing fast rate speech as compared with typically developing (TD) children. Method Sixteen French children with SLI (8–13 years old) with mainly expressive phonological disorders and with preserved comprehension and 16 age-matched TD children performed a judgment task on sentences produced 1) at normal rate, 2) at fast rate or 3) time-compressed. Sensitivity index (d′) to semantically incongruent sentence-final words was measured. Results Overall children with SLI perform significantly worse than TD children. Importantly, as revealed by the significant Group × Speech Rate interaction, children with SLI find it more challenging than TD children to process both naturally or artificially accelerated speech. The two groups do not significantly differ in normal rate speech processing. Conclusion In agreement with rhythm-processing deficits in atypical language development, our results suggest that children with SLI face difficulties adjusting to rapid speech rate. These findings are interpreted in light of temporal sampling and prosodic phrasing frameworks and of oscillatory mechanisms underlying speech perception. PMID:29373610
Ultra fast all-optical fiber pressure sensor for blast event evaluation
NASA Astrophysics Data System (ADS)
Wu, Nan; Wang, Wenhui; Tian, Ye; Niezrecki, Christopher; Wang, Xingwei
2011-05-01
Traumatic brain injury (TBI) is a great potential threat to soldiers who are exposed to explosions or athletes who receive cranial impacts. Protecting people from TBI has recently attracted a significant amount of attention due to recent military operations in the Middle East. Recording pressure transient data in a blast event is very critical to the understanding of the effects of blast events on TBI. However, due to the fast change of the pressure during blast events, very few sensors have the capability to effectively track the dynamic pressure transients. This paper reports an ultra fast, miniature and all-optical fiber pressure sensor which could be mounted at different locations of a helmet to measure the fast changing pressure simultaneously. The sensor is based on Fabry-Perot (FP) principle. The end face of the fiber is wet etched. A well controlled thickness silicon dioxide diaphragm is thermal bonded on the end face to form an FP cavity. A shock tube test was conducted at Natick Soldier Research Development and Engineering Center, where the sensors were mounted in a shock tube side by side with a reference sensor to measure the rapidly changing pressure. The results of the test demonstrated that the sensor developed had an improved rise time (shorter than 0.4 μs) when compared to a commercially available reference sensor.
NASA Astrophysics Data System (ADS)
Hafner, D.
2015-09-01
The application of ground-based boresight sources for calibration and testing of tracking antennas usually entails various difficulties, mostly due to unwanted ground effects. To avoid this problem, DLR MORABA developed a small, lightweight, frequency-adjustable S-band boresight source, mounted on a small remote-controlled multirotor aircraft. Highly accurate GPS-supported, position and altitude control functions allow both, very steady positioning of the aircraft in mid-air, and precise waypoint-based, semi-autonomous flights. In contrast to fixed near-ground boresight sources this flying setup enables to avoid obstructions in the Fresnel zone between source and antenna. Further, it minimizes ground reflections and other multipath effects which can affect antenna calibration. In addition, the large operating range of a flying boresight simplifies measurements in the far field of the antenna and permits undisturbed antenna pattern tests. A unique application is the realistic simulation of sophisticated flight paths, including overhead tracking and demanding trajectories of fast objects such as sounding rockets. Likewise, dynamic tracking tests are feasible which provide crucial information about the antenna pedestal performance — particularly at high elevations — and reveal weaknesses in the autotrack control loop of tracking antenna systems. During acceptance tests of MORABA's new tracking antennas, a manned aircraft was never used, since the Flying Boresight surpassed all expectations regarding usability, efficiency, and precision. Hence, it became an integral part of MORABA's standard antenna setup and calibration procedures.
A fast-initializing digital equalizer with on-line tracking for data communications
NASA Technical Reports Server (NTRS)
Houts, R. C.; Barksdale, W. J.
1974-01-01
A theory is developed for a digital equalizer for use in reducing intersymbol interference (ISI) on high speed data communications channels. The equalizer is initialized with a single isolated transmitter pulse, provided the signal-to-noise ratio (SNR) is not unusually low, then switches to a decision directed, on-line mode of operation that allows tracking of channel variations. Conditions for optimal tap-gain settings are obtained first for a transversal equalizer structure by using a mean squared error (MSE) criterion, a first order gradient algorithm to determine the adjustable equalizer tap-gains, and a sequence of isolated initializing pulses. Since the rate of tap-gain convergence depends on the eigenvalues of a channel output correlation matrix, convergence can be improved by making a linear transformation on to obtain a new correlation matrix.
NASA Astrophysics Data System (ADS)
Olofsson, K. Erik J.; Brunsell, Per R.; Witrant, Emmanuel; Drake, James R.
2010-10-01
Recent developments and applications of system identification methods for the reversed-field pinch (RFP) machine EXTRAP T2R have yielded plasma response parameters for decoupled dynamics. These data sets are fundamental for a real-time implementable fast Fourier transform (FFT) decoupled discrete-time fixed-order strongly stabilizing synthesis as described in this work. Robustness is assessed over the data set by bootstrap calculation of the sensitivity transfer function worst-case H_{\\infty} -gain distribution. Output tracking and magnetohydrodynamic mode m = 1 tracking are considered in the same framework simply as two distinct weighted traces of a performance channel output-covariance matrix as derived from the closed-loop discrete-time Lyapunov equation. The behaviour of the resulting multivariable controller is investigated with dedicated T2R experiments.
Integrated mobile robot control
NASA Technical Reports Server (NTRS)
Amidi, Omead; Thorpe, Charles
1991-01-01
This paper describes the structure, implementation, and operation of a real-time mobile robot controller which integrates capabilities such as: position estimation, path specification and tracking, human interfaces, fast communication, and multiple client support. The benefits of such high-level capabilities in a low-level controller was shown by its implementation for the Navlab autonomous vehicle. In addition, performance results from positioning and tracking systems are reported and analyzed.
Votava, Ondrej; Mašát, Milan; Parker, Alexander E; Jain, Chaithania; Fittschen, Christa
2012-04-01
We present in this work a new tracking servoloop electronics for continuous wave cavity-ringdown absorption spectroscopy (cw-CRDS) and its application to time resolved cw-CRDS measurements by coupling the system with a pulsed laser photolysis set-up. The tracking unit significantly increases the repetition rate of the CRDS events and thus improves effective time resolution (and/or the signal-to-noise ratio) in kinetics studies with cw-CRDS in given data acquisition time. The tracking servoloop uses novel strategy to track the cavity resonances that result in a fast relocking (few ms) after the loss of tracking due to an external disturbance. The microcontroller based design is highly flexible and thus advanced tracking strategies are easy to implement by the firmware modification without the need to modify the hardware. We believe that the performance of many existing cw-CRDS experiments, not only time-resolved, can be improved with such tracking unit without any additional modification to the experiment. © 2012 American Institute of Physics
Decontaminate feature for tracking: adaptive tracking via evolutionary feature subset
NASA Astrophysics Data System (ADS)
Liu, Qiaoyuan; Wang, Yuru; Yin, Minghao; Ren, Jinchang; Li, Ruizhi
2017-11-01
Although various visual tracking algorithms have been proposed in the last 2-3 decades, it remains a challenging problem for effective tracking with fast motion, deformation, occlusion, etc. Under complex tracking conditions, most tracking models are not discriminative and adaptive enough. When the combined feature vectors are inputted to the visual models, this may lead to redundancy causing low efficiency and ambiguity causing poor performance. An effective tracking algorithm is proposed to decontaminate features for each video sequence adaptively, where the visual modeling is treated as an optimization problem from the perspective of evolution. Every feature vector is compared to a biological individual and then decontaminated via classical evolutionary algorithms. With the optimized subsets of features, the "curse of dimensionality" has been avoided while the accuracy of the visual model has been improved. The proposed algorithm has been tested on several publicly available datasets with various tracking challenges and benchmarked with a number of state-of-the-art approaches. The comprehensive experiments have demonstrated the efficacy of the proposed methodology.
Delirium, Frailty, and Fast-Track Surgery in Oncogeriatrics: Is There a Link?
Monacelli, Fiammetta; Signori, Alessio; Prefumo, Matteo; Giannotti, Chiara; Nencioni, Alessio; Romairone, Emanuele; Scabini, Stefano; Odetti, Patrizio
2018-01-01
Background/Aims Postoperative delirium (POD) is more frequent in elderly patients undergoing major cancer surgery. The interplay between individual clinical vulnerability and a series of perioperative factors seems to play a relevant role. Surgery is the first-line treatment option for cancer, and fast-track surgery (FTS) has been documented to decrease postoperative complications. The study sought to assess, after comprehensive geriatric assessment (CGA) and frailty stratification (Rockwood 40 items index), which perioperative parameters were predictive of POD development in elderly patients undergoing FTS for colorectal cancer. Methods A total of 107 consecutive subjects admitted for elective colorectal FTS were enrolled. All patients underwent CGA, frailly stratification, Timed up & go (TUG) test, 4AT test for delirium screening, anesthesiologists physical status classification, and Dindo-Clavien classification. Results The incidence of POD was 12.3%. Patients’ prevalent clinical phenotype was pre-frail. The multivariate analysis indicated physical performance (TUG in seconds) as the most significant predictor of POD for each second of increase. Conclusions Only few procedure-specific studies have examined the impact of FTS for colorectal cancer on POD. This is the first study to investigate the risk factors for POD, in a vulnerable octogenarian oncogeriatric population submitted to FTS surgery and frailty stratification. PMID:29515621
Lamberti, Alfredo; Vanlanduit, Steve; De Pauw, Ben; Berghmans, Francis
2014-01-01
The working principle of fiber Bragg grating (FBG) sensors is mostly based on the tracking of the Bragg wavelength shift. To accomplish this task, different algorithms have been proposed, from conventional maximum and centroid detection algorithms to more recently-developed correlation-based techniques. Several studies regarding the performance of these algorithms have been conducted, but they did not take into account spectral distortions, which appear in many practical applications. This paper addresses this issue and analyzes the performance of four different wavelength tracking algorithms (maximum detection, centroid detection, cross-correlation and fast phase-correlation) when applied to distorted FBG spectra used for measuring dynamic loads. Both simulations and experiments are used for the analyses. The dynamic behavior of distorted FBG spectra is simulated using the transfer-matrix approach, and the amount of distortion of the spectra is quantified using dedicated distortion indices. The algorithms are compared in terms of achievable precision and accuracy. To corroborate the simulation results, experiments were conducted using three FBG sensors glued on a steel plate and subjected to a combination of transverse force and vibration loads. The analysis of the results showed that the fast phase-correlation algorithm guarantees the best combination of versatility, precision and accuracy. PMID:25521386
Implementation of the Spanish ERAS program in bariatric surgery.
Ruiz-Tovar, Jaime; Muñoz, José Luis; Royo, Pablo; Duran, Manuel; Redondo, Elisabeth; Ramirez, Jose Manuel
2018-03-08
The essence of Enhanced Recovery After Surgery (ERAS) programs is the multimodal approach, and many authors have demonstrated safety and feasibility in fast track bariatric surgery. According to this concept, a multidisciplinary ERAS program for bariatric surgery has been developed by the Spanish Fast Track Group (ERAS Spain). The aim of this study was to analyze the initial implementation of this Spanish National ERAS protocol in bariatric surgery, comparing it with a historical cohort receiving standard care. A multi-centric prospective study was performed, including 233 consecutive patients undergoing bariatric surgery during 2015 and following ERAS protocol. It was compared with a historical cohort of 286 patients, who underwent bariatric surgery at the same institutions between 2013 and 2014 and following standard care. Compliance with the protocol, morbidity, mortality, hospital stay and readmission were evaluated. Bariatric techniques performed were Roux-en-Y gastric bypass and sleeve gastrectomy. There were no significant differences in complications, mortality and readmission. Postoperative pain and hospital stay were significantly lower in the ERAS group. The total compliance to protocol was 80%. The Spanish National ERAS protocol is a safe issue, obtaining similar results to standard care in terms of complications, reoperations, mortality and readmissions. It is associated with less postoperative pain and earlier hospital discharge.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deptuch, Gregory; Hoff, James; Jindariani, Sergo
Extremely fast pattern recognition capabilities are necessary to find and fit billions of tracks at the hardware trigger level produced every second anticipated at high luminosity LHC (HL-LHC) running conditions. Associative Memory (AM) based approaches for fast pattern recognition have been proposed as a potential solution to the tracking trigger. However, at the HL-LHC, there is much less time available and speed performance must be improved over previous systems while maintaining a comparable number of patterns. The Vertically Integrated Pattern Recognition Associative Memory (VIPRAM) Project aims to achieve the target pattern density and performance goal using 3DIC technology. The firstmore » step taken in the VIPRAM work was the development of a 2D prototype (protoVIPRAM00) in which the associative memory building blocks were designed to be compatible with the 3D integration. In this paper, we present the results from extensive performance studies of the protoVIPRAM00 chip in both realistic HL-LHC and extreme conditions. Results indicate that the chip operates at the design frequency of 100 MHz with perfect correctness in realistic conditions and conclude that the building blocks are ready for 3D stacking. We also present performance boundary characterization of the chip under extreme conditions.« less
Two-degrees-of-freedom piezo-driven fast steering mirror with cross-axis decoupling capability
NASA Astrophysics Data System (ADS)
Shao, Shubao; Tian, Zheng; Song, Siyang; Xu, Minglong
2018-05-01
Because mechanical cross coupling between its axes would lead to degradation of the scanning precision of a piezo-driven fast steering mirror (PFSM), a two-degrees-of-freedom (2-DoF) PFSM with a cross-axis decoupling capability, in which 2-DoF flexure hinges are used, is proposed in this work. The overall structure of the proposed PFSM is first introduced and then both static and dynamic models are established analytically; in addition, the decoupling mechanism is described in detail and the low dynamic cross coupling ratios that occur between the two DoFs are shown. Because of the decoupling property of the PFSM, the 2-DoF motion is treated as a combination of two independent one-degree-of-freedom (1-DoF) motions and two independent proportional-integral-derivative controllers are thus used separately in the control of the two DoFs. Based on this control strategy, experiments involving both 1-DoF trajectory tracking and 2-DoF trajectory tracking are implemented. The test results show that the proposed PFSM can achieve the tilt range of ±7 mrad for both axes with the low coupling ratios that are less than 2% (-34 dB), and the bandwidths of both axes are higher than 810 Hz; in addition, the maximal tracking full scale range errors for 1-DoF trajectory tracking and 2-DoF trajectory tracking are less than 0.2% and 1%, respectively, where the larger error of 2-DoF trajectory tracking is mainly caused by the remaining cross coupling between axes.
Multiple-target tracking implementation in the ebCMOS camera system: the LUSIPHER prototype
NASA Astrophysics Data System (ADS)
Doan, Quang Tuyen; Barbier, Remi; Dominjon, Agnes; Cajgfinger, Thomas; Guerin, Cyrille
2012-06-01
The domain of the low light imaging systems progresses very fast, thanks to detection and electronic multiplication technology evolution, such as the emCCD (electron multiplying CCD) or the ebCMOS (electron bombarded CMOS). We present an ebCMOS camera system that is able to track every 2 ms more than 2000 targets with a mean number of photons per target lower than two. The point light sources (targets) are spots generated by a microlens array (Shack-Hartmann) used in adaptive optics. The Multiple-Target-Tracking designed and implemented on a rugged workstation is described. The results and the performances of the system on the identification and tracking are presented and discussed.
Multi-Stage Target Tracking with Drift Correction and Position Prediction
NASA Astrophysics Data System (ADS)
Chen, Xin; Ren, Keyan; Hou, Yibin
2018-04-01
Most existing tracking methods are hard to combine accuracy and performance, and do not consider the shift between clarity and blur that often occurs. In this paper, we propound a multi-stage tracking framework with two particular modules: position prediction and corrective measure. We conduct tracking based on correlation filter with a corrective measure module to increase both performance and accuracy. Specifically, a convolutional network is used for solving the blur problem in realistic scene, training methodology that training dataset with blur images generated by the three blur algorithms. Then, we propose a position prediction module to reduce the computation cost and make tracker more capable of fast motion. Experimental result shows that our tracking method is more robust compared to others and more accurate on the benchmark sequences.
Determination of time zero from a charged particle detector
Green, Jesse Andrew [Los Alamos, NM
2011-03-15
A method, system and computer program is used to determine a linear track having a good fit to a most likely or expected path of charged particle passing through a charged particle detector having a plurality of drift cells. Hit signals from the charged particle detector are associated with a particular charged particle track. An initial estimate of time zero is made from these hit signals and linear tracks are then fit to drift radii for each particular time-zero estimate. The linear track having the best fit is then searched and selected and errors in fit and tracking parameters computed. The use of large and expensive fast detectors needed to time zero in the charged particle detectors can be avoided by adopting this method and system.
Wodlin, Ninnie Borendal; Nilsson, Lena; Arestedt, Kristofer; Kjølhede, Preben
2011-04-01
To determine whether postoperative symptoms differ between women who undergo abdominal benign hysterectomy in a fast-track model under general anesthesia or spinal anesthesia with intrathecal morphine. Secondary analysis from a randomized, open, multicenter study. Five hospitals in south-east Sweden. One-hundred and eighty women scheduled for benign hysterectomy were randomized; 162 completed the study; 82 were allocated to spinal and 80 to general anesthesia. The Swedish Postoperative Symptoms Questionnaire, completed daily for 1 week and thereafter once a week until 5 weeks postoperatively. Occurrence, intensity and duration of postoperative symptoms. Women who had hysterectomy under spinal anesthesia with intrathecal morphine experienced significantly less discomfort postoperatively compared with those who had the operation under general anesthesia. Spinal anesthesia reduced the need for opioids postoperatively. The most common symptoms were pain, nausea and vomiting, itching, drowsiness and fatigue. Abdominal pain, drowsiness and fatigue occurred significantly less often and with lower intensity among the spinal anesthesia group. Although postoperative nausea and vomiting was reported equally in the two groups, vomiting episodes were reported significantly more often during the first day after surgery in the spinal anesthesia group. Spinal anesthesia was associated with a higher prevalence of postoperative itching. Spinal anesthesia with intrathecal morphine carries advantages regarding postoperative symptoms and recovery following fast-track abdominal hysterectomy. © 2011 The Authors Acta Obstetricia et Gynecologica Scandinavica© 2011 Nordic Federation of Societies of Obstetrics and Gynecology.
How to optimize the economic viability of thyroid surgery in a French public hospital?
D'Hubert, E; Proske, J-M
2010-08-01
Physicians in France have been asked to change their day-to-day medical practice to reduce overall costs. We examine ways to achieve this goal in thyroid surgery. We defined and implemented a clinical pathway to optimize the economic viability of thyroid surgery by increasing revenues and lowering expenses. An increase in revenue was achieved by decreasing patient length of stay (LOS) through the use of a fast-track rehabilitation protocol. Expenses were decreased by performing all pre-operative work-up in the out-patient setting and by decreasing costs in the operating room. For 292 consecutive patients who underwent thyroidectomy, the average LOS has been decreased over time to a mean of 2.03 days in 2008; 96% of patients were discharged on the first postoperative day. These results were primarily achieved by using a fast-track rehabilitation clinical pathway, and no increase in postoperative morbidity was noted. Operating time was decreased by 20% through the use of a second surgical assistant and hemostatic scissors but this improvement did not translate into better daily utilization of the operating room. The economic profitability of thyroid surgery is improved when mean LOS is reduced to 2 days through a fast-track protocol. Decreasing the duration of hospitalization was more effective than decreasing operative duration in controlling overall costs. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
Patil, P; Williams, M; Maw, W W; Achilleos, K; Elsideeg, S; Dejaco, C; Borg, F; Gupta, S; Dasgupta, B
2015-01-01
To investigate the effectiveness of a fast track pathway (FTP) on sight loss in patients with suspected giant cell arteritis (GCA). A longitudinal observational cohort study was conducted in the secondary care rheumatology department. One hundred and thirty-five newly referred suspected GCA patients seen via the FTP (Jan. 2012-Dec. 2013) were compared to 81 patients seen through the conventional referral and review system (Jan. 2009-Dec. 2011). The FTP resulted in significant reduction in irreversible sight loss from 37.0% (as seen in the historical cohort 2009-2011) to 9.0 % (2012-2013, OR 0.17, p=0.001). Adjustment for clinical and demographic parameters including known risk factors for GCA associated blindness did not significantly change the primary result (OR 0.08, p=0.001). FTP resulted in a reduction of time from symptom onset to diagnosis, particularly by reduction of time from general practitioner's (GP) referral to the rheumatology review (79% of FTP patients were seen within one working day compared to 64.6 % in the conventional pathway, p=0.023). The FTP has seen a reduction in number of GP appointments. There was a significant reduction of permanent sight loss with a fast track GCA pathway. The effect may be due to multiple factors including better GP education and reduction in delayed diagnosis. These results need verification at other sites.
An automated data exploitation system for airborne sensors
NASA Astrophysics Data System (ADS)
Chen, Hai-Wen; McGurr, Mike
2014-06-01
Advanced wide area persistent surveillance (WAPS) sensor systems on manned or unmanned airborne vehicles are essential for wide-area urban security monitoring in order to protect our people and our warfighter from terrorist attacks. Currently, human (imagery) analysts process huge data collections from full motion video (FMV) for data exploitation and analysis (real-time and forensic), providing slow and inaccurate results. An Automated Data Exploitation System (ADES) is urgently needed. In this paper, we present a recently developed ADES for airborne vehicles under heavy urban background clutter conditions. This system includes four processes: (1) fast image registration, stabilization, and mosaicking; (2) advanced non-linear morphological moving target detection; (3) robust multiple target (vehicles, dismounts, and human) tracking (up to 100 target tracks); and (4) moving or static target/object recognition (super-resolution). Test results with real FMV data indicate that our ADES can reliably detect, track, and recognize multiple vehicles under heavy urban background clutters. Furthermore, our example shows that ADES as a baseline platform can provide capability for vehicle abnormal behavior detection to help imagery analysts quickly trace down potential threats and crimes.
Fast front-end electronics for semiconductor tracking detectors: Trends and perspectives
NASA Astrophysics Data System (ADS)
Rivetti, Angelo
2014-11-01
In the past few years, extensive research efforts pursued by both the industry and the academia have lead to major improvements in the performance of Analog to Digital Converters (ADCs) and Time to Digital Converters (TDCs). ADCs achieving 8-10 bit resolution, 50-100 MHz conversion frequency and less than 1 mW power consumption are the today's standard, while TDCs have reached sub-picosecond time resolution. These results have been made possible by architectural upgrades combined with the use of ultra deep submicron CMOS technologies with minimum feature size of 130 nm or smaller. Front-end ASICs in which a prompt digitization is followed by signal conditioning in the digital domain can now be envisaged also within the tight power budget typically available in high density tracking systems. Furthermore, tracking detectors embedding high resolution timing capabilities are gaining interest. In the paper, ADC's and TDC's developments which are of particular relevance for the design front-end electronics for semiconductor trackers are discussed along with the benefits and challenges of exploiting such high performance building blocks in implementing the next generation of ASICs for high granularity particle detectors.
Fast-synchronizing high-fidelity spread-spectrum receiver
Moore, Michael Roy; Smith, Stephen Fulton; Emery, Michael Steven
2004-06-01
A fast-synchronizing receiver having a circuit including an equalizer configured for manipulating an analog signal; a detector in communication with the equalizer; a filter in communication with the detector; an oscillator in communication with the filter; a gate for receiving the manipulated signal; a circuit portion for synchronizing and tracking the manipulated signal; a summing circuit in communication with the circuit portion; and an output gate.
Fast and Efficient Feature Engineering for Multi-Cohort Analysis of EHR Data.
Ozery-Flato, Michal; Yanover, Chen; Gottlieb, Assaf; Weissbrod, Omer; Parush Shear-Yashuv, Naama; Goldschmidt, Yaara
2017-01-01
We present a framework for feature engineering, tailored for longitudinal structured data, such as electronic health records (EHRs). To fast-track feature engineering and extraction, the framework combines general-use plug-in extractors, a multi-cohort management mechanism, and modular memoization. Using this framework, we rapidly extracted thousands of features from diverse and large healthcare data sources in multiple projects.
Registration of retinal sequences from new video-ophthalmoscopic camera.
Kolar, Radim; Tornow, Ralf P; Odstrcilik, Jan; Liberdova, Ivana
2016-05-20
Analysis of fast temporal changes on retinas has become an important part of diagnostic video-ophthalmology. It enables investigation of the hemodynamic processes in retinal tissue, e.g. blood-vessel diameter changes as a result of blood-pressure variation, spontaneous venous pulsation influenced by intracranial-intraocular pressure difference, blood-volume changes as a result of changes in light reflection from retinal tissue, and blood flow using laser speckle contrast imaging. For such applications, image registration of the recorded sequence must be performed. Here we use a new non-mydriatic video-ophthalmoscope for simple and fast acquisition of low SNR retinal sequences. We introduce a novel, two-step approach for fast image registration. The phase correlation in the first stage removes large eye movements. Lucas-Kanade tracking in the second stage removes small eye movements. We propose robust adaptive selection of the tracking points, which is the most important part of tracking-based approaches. We also describe a method for quantitative evaluation of the registration results, based on vascular tree intensity profiles. The achieved registration error evaluated on 23 sequences (5840 frames) is 0.78 ± 0.67 pixels inside the optic disc and 1.39 ± 0.63 pixels outside the optic disc. We compared the results with the commonly used approaches based on Lucas-Kanade tracking and scale-invariant feature transform, which achieved worse results. The proposed method can efficiently correct particular frames of retinal sequences for shift and rotation. The registration results for each frame (shift in X and Y direction and eye rotation) can also be used for eye-movement evaluation during single-spot fixation tasks.
Identifying ethical issues in the development of vaccines and in vaccination.
Johari, Veena
2017-01-01
Vaccines are a widely accepted public health intervention. They are also a profitable tool for pharmaceutical companies manufacturing vaccines. There are many vaccines in the pipeline, for various diseases, or as combination vaccines for several diseases. However, there is also a growing concern about vaccines and the manner in which they are developed and approved by the authorities. Approvals are fast tracked and adverse events and serious adverse events following vaccination are seldom reported once the vaccine gets its marketing approval. Thus, vaccines have been clouded with many controversies and their use as a public health tool to prevent diseases is constantly under challenge.
Radiation-hardened fast acquisition/weak signal tracking system and method
NASA Technical Reports Server (NTRS)
Winternitz, Luke (Inventor); Boegner, Gregory J. (Inventor); Sirotzky, Steve (Inventor)
2009-01-01
A global positioning system (GPS) receiver and method of acquiring and tracking GPS signals comprises an antenna adapted to receive GPS signals; an analog radio frequency device operatively connected to the antenna and adapted to convert the GPS signals from an analog format to a digital format; a plurality of GPS signal tracking correlators operatively connected to the analog RF device; a GPS signal acquisition component operatively connected to the analog RF device and the plurality of GPS signal tracking correlators, wherein the GPS signal acquisition component is adapted to calculate a maximum vector on a databit correlation grid; and a microprocessor operatively connected to the plurality of GPS signal tracking correlators and the GPS signal acquisition component, wherein the microprocessor is adapted to compare the maximum vector with a predetermined correlation threshold to allow the GPS signal to be fully acquired and tracked.
Theoretical prediction of the impact of Auger recombination on charge collection from an ion track
NASA Technical Reports Server (NTRS)
Edmonds, Larry D.
1991-01-01
A recombination mechanism that significantly reduces charge collection from very dense ion tracks in silicon devices was postulated by Zoutendyk et al. The theoretical analysis presented here concludes that Auger recombination is such a mechanism and is of marginal importance for higher density tracks produced by 270-MeV krypton, but of major importance for higher density tracks. The analysis shows that recombination loss is profoundly affected by track diffusion. As the track diffuses, the density and recombination rate decrease so fast that the linear density (number of electron-hole pairs per unit length) approaches a non-zero limiting value as t yields infinity. Furthermore, the linear density is very nearly equal to this limiting value in a few picoseconds or less. When Auger recombination accompanies charge transport processes that have much longer time scales, it can be simulated by assigning a reduced linear energy transfer to the ion.
Jiang, Jingfeng; Hall, Timothy J
2011-04-01
A hybrid approach that inherits both the robustness of the regularized motion tracking approach and the efficiency of the predictive search approach is reported. The basic idea is to use regularized speckle tracking to obtain high-quality seeds in an explorative search that can be used in the subsequent intelligent predictive search. The performance of the hybrid speckle-tracking algorithm was compared with three published speckle-tracking methods using in vivo breast lesion data. We found that the hybrid algorithm provided higher displacement quality metric values, lower root mean squared errors compared with a locally smoothed displacement field, and higher improvement ratios compared with the classic block-matching algorithm. On the basis of these comparisons, we concluded that the hybrid method can further enhance the accuracy of speckle tracking compared with its real-time counterparts, at the expense of slightly higher computational demands. © 2011 IEEE
Dithering Digital Ripple Correlation Control for Photovoltaic Maximum Power Point Tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barth, C; Pilawa-Podgurski, RCN
This study demonstrates a new method for rapid and precise maximum power point tracking in photovoltaic (PV) applications using dithered PWM control. Constraints imposed by efficiency, cost, and component size limit the available PWM resolution of a power converter, and may in turn limit the MPP tracking efficiency of the PV system. In these scenarios, PWM dithering can be used to improve average PWM resolution. In this study, we present a control technique that uses ripple correlation control (RCC) on the dithering ripple, thereby achieving simultaneous fast tracking speed and high tracking accuracy. Moreover, the proposed method solves some ofmore » the practical challenges that have to date limited the effectiveness of RCC in solar PV applications. We present a theoretical derivation of the principles behind dithering digital ripple correlation control, as well as experimental results that show excellent tracking speed and accuracy with basic hardware requirements.« less
Research of maneuvering target prediction and tracking technology based on IMM algorithm
NASA Astrophysics Data System (ADS)
Cao, Zheng; Mao, Yao; Deng, Chao; Liu, Qiong; Chen, Jing
2016-09-01
Maneuvering target prediction and tracking technology is widely used in both military and civilian applications, the study of those technologies is all along the hotspot and difficulty. In the Electro-Optical acquisition-tracking-pointing system (ATP), the primary traditional maneuvering targets are ballistic target, large aircraft and other big targets. Those targets have the features of fast velocity and a strong regular trajectory and Kalman Filtering and polynomial fitting have good effects when they are used to track those targets. In recent years, the small unmanned aerial vehicles developed rapidly for they are small, nimble and simple operation. The small unmanned aerial vehicles have strong maneuverability in the observation system of ATP although they are close-in, slow and small targets. Moreover, those vehicles are under the manual operation, therefore, the acceleration of them changes greatly and they move erratically. So the prediction and tracking precision is low when traditional algorithms are used to track the maneuvering fly of those targets, such as speeding up, turning, climbing and so on. The interacting multiple model algorithm (IMM) use multiple models to match target real movement trajectory, there are interactions between each model. The IMM algorithm can switch model based on a Markov chain to adapt to the change of target movement trajectory, so it is suitable to solve the prediction and tracking problems of the small unmanned aerial vehicles because of the better adaptability of irregular movement. This paper has set up model set of constant velocity model (CV), constant acceleration model (CA), constant turning model (CT) and current statistical model. And the results of simulating and analyzing the real movement trajectory data of the small unmanned aerial vehicles show that the prediction and tracking technology based on the interacting multiple model algorithm can get relatively lower tracking error and improve tracking precision comparing with traditional algorithms.
A combined analysis technique for the search for fast magnetic monopoles with the MACRO detector
NASA Astrophysics Data System (ADS)
MACRO Collaboration; Ambrosio, M.; Antolini, R.; Auriemma, G.; Bakari, D.; Baldini, A.; Barbarino, G. C.; Barish, B. C.; Battistoni, G.; Becherini, Y.; Bellotti, R.; Bemporad, C.; Bernardini, P.; Bilokon, H.; Bloise, C.; Bower, C.; Brigida, M.; Bussino, S.; Cafagna, F.; Calicchio, M.; Campana, D.; Carboni, M.; Caruso, R.; Cecchini, S.; Cei, F.; Chiarella, V.; Choudhary, B. C.; Coutu, S.; De Cataldo, G.; Dekhissi, H.; De Marzo, C.; De Mitri, I.; Derkaoui, J.; De Vincenzi, M.; DiCredico, A.; Erriquez, O.; Favuzzi, C.; Forti, C.; Fusco, P.; Giacomelli, G.; Giannini, G.; Giglietto, N.; Giorgini, M.; Grassi, M.; Grillo, A.; Guarino, F.; Gustavino, C.; Habig, A.; Heinz, R.; Iarocci, E.; Katsavounidis, E.; Katsavounidis, I.; Kearns, E.; Kim, H.; Kyriazopoulou, S.; Lamanna, E.; Lane, C.; Levin, D. S.; Lipari, P.; Longley, N. P.; Longo, M. J.; Loparco, F.; Maaroufi, F.; Mancarella, G.; Mandrioli, G.; Manzoor, S.; Margiotta, A.; Marini, A.; Martello, D.; Marzari-Chiesa, A.; Mazziotta, M. N.; Michael, D. G.; Monacelli, P.; Montaruli, T.; Monteno, M.; Mufson, S.; Musser, J.; Nicolò, D.; Nolty, R.; Orth, C.; Osteria, G.; Palamara, O.; Patera, V.; Patrizii, L.; Pazzi, R.; Peck, C. W.; Perrone, L.; Petrera, S.; Popa, V.; Reynoldson, J.; Ronga, F.; Rrhioua, A.; Satriano, C.; Scapparone, E.; Scholberg, K.; Sciubba, A.; Serra, P.; Sioli, M.; Sirri, G.; Sitta, M.; Spinelli, P.; Spinetti, M.; Spurio, M.; Steinberg, R.; Stone, J. L.; Sulak, L. R.; Surdo, A.; Tarlè, G.; Togo, V.; Vakili, M.; Walter, C. W.; Webb, R.
2002-08-01
We describe a search method for fast moving (β=v/c>5×10-3) magnetic monopoles using simultaneously the scintillator, streamer tube and track-etch subdetectors of the MACRO apparatus. The first two subdetectors are used primarily for the identification of candidates while the track-etch one is used as the final tool for their rejection or confirmation. Using this technique, a first sample of more than two years of data has been analyzed without any evidence of a magnetic monopole. We set a 90% CL upper limit to the local monopole flux of 1.5×10-15 cm-2s-1sr-1 in the velocity range 5×10-3<=β<=0.99 and for nucleon decay catalysis cross-section smaller than /~1 mb
Initial Impact of the Fast Track Prevention Trial for Conduct Problems: II. Classroom Effects
2009-01-01
This study examined the effectiveness of the universal component of the Fast Track prevention model: the PATHS (Promoting Alternative THinking Strategies) curriculum and teacher consultation. This randomized clinical trial involved 198 intervention and 180 comparison classrooms from neighborhoods with greater than average crime in 4 U.S. locations. In the intervention schools, Grade 1 teachers delivered a 57-lesson social competence intervention focused on self-control, emotional awareness, peer relations, and problem solving. Findings indicated significant effects on peer ratings of aggression and hyperactive–disruptive behavior and observer ratings of classroom atmosphere. Quality of implementation predicted variation in assessments of classroom functioning. The results are discussed in terms of both the efficacy of universal, school-based prevention models and the need to examine comprehensive, multiyear programs. PMID:10535231
NASA Astrophysics Data System (ADS)
Leitzinger, M.; Odert, P.; Zaqarashvili, T. V.; Greimel, R.; Hanslmeier, A.; Lammer, H.
2016-11-01
We present the analysis of six nights of spectroscopic monitoring of two young and fast rotating late-type stars, namely the dMe star HK Aqr and the dG/dK star PZ Tel. On both stars, we detect absorption features reminiscent of signatures of corotating cool clouds or prominences visible in Hα. Several prominences on HK Aqr show periodic variability in the prominence tracks which follow a sinusoidal motion (indication of prominence oscillations). On PZ Tel, we could not find any periodic variability in the prominence tracks. By fitting sinusoidal functions to the prominence tracks, we derive amplitudes and periods which are similar to those of large-amplitude oscillations seen in solar prominences. In one specific event, we also derive a periodic variation of the prominence track in the Hβ spectral line which shows an anti-phase variation with the one derived for the Hα spectral line. Using these parameters and estimated mass density of a prominence on HK Aqr, we derive a minimum magnetic field strength of ˜2 G. The relatively low strength of the magnetic field is explained by the large height of this stellar prominence (≥ 0.67 stellar radii above the surface).
Fast human pose estimation using 3D Zernike descriptors
NASA Astrophysics Data System (ADS)
Berjón, Daniel; Morán, Francisco
2012-03-01
Markerless video-based human pose estimation algorithms face a high-dimensional problem that is frequently broken down into several lower-dimensional ones by estimating the pose of each limb separately. However, in order to do so they need to reliably locate the torso, for which they typically rely on time coherence and tracking algorithms. Their losing track usually results in catastrophic failure of the process, requiring human intervention and thus precluding their usage in real-time applications. We propose a very fast rough pose estimation scheme based on global shape descriptors built on 3D Zernike moments. Using an articulated model that we configure in many poses, a large database of descriptor/pose pairs can be computed off-line. Thus, the only steps that must be done on-line are the extraction of the descriptors for each input volume and a search against the database to get the most likely poses. While the result of such process is not a fine pose estimation, it can be useful to help more sophisticated algorithms to regain track or make more educated guesses when creating new particles in particle-filter-based tracking schemes. We have achieved a performance of about ten fps on a single computer using a database of about one million entries.
Michael H. L. S. Wang; Cancelo, Gustavo; Green, Christopher; ...
2016-06-25
Here, we explore the Micron Automata Processor (AP) as a suitable commodity technology that can address the growing computational needs of pattern recognition in High Energy Physics (HEP) experiments. A toy detector model is developed for which an electron track confirmation trigger based on the Micron AP serves as a test case. Although primarily meant for high speed text-based searches, we demonstrate a proof of concept for the use of the Micron AP in a HEP trigger application.
Smith, Chris Llewellyn; Cowley, Steve
2010-01-01
The promise, status and challenges of developing fusion power are outlined. The key physics and engineering principles are described and recent progress quantified. As the successful demonstration of 16 MW of fusion in 1997 in the Joint European Torus showed, fusion works. The central issue is therefore to make it work reliably and economically on the scale of a power station. We argue that to meet this challenge in 30 years we must follow the aggressive programme known as the ‘Fast Track to Fusion’. This programme is described in some detail. PMID:20123748
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michael H. L. S. Wang; Cancelo, Gustavo; Green, Christopher
Here, we explore the Micron Automata Processor (AP) as a suitable commodity technology that can address the growing computational needs of pattern recognition in High Energy Physics (HEP) experiments. A toy detector model is developed for which an electron track confirmation trigger based on the Micron AP serves as a test case. Although primarily meant for high speed text-based searches, we demonstrate a proof of concept for the use of the Micron AP in a HEP trigger application.
Recent results on CVD diamond radiation sensors
NASA Astrophysics Data System (ADS)
Weilhammer, P.; Adam, W.; Bauer, C.; Berdermann, E.; Bogani, F.; Borchi, E.; Bruzzi, M.; Colledani, C.; Conway, J.; Dabrowski, W.; Delpierre, P.; Deneuville, A.; Dulinski, W.; v. d. Eijk, R.; van Eijk, B.; Fallou, A.; Fish, D.; Fried, M.; Gan, K. K.; Gheeraert, E.; Grigoriev, E.; Hallewell, G.; Hall-Wilton, R.; Han, S.; Hartjes, F.; Hrubec, J.; Husson, D.; Kagan, H.; Kania, D.; Kaplon, J.; Kass, R.; Knopfle, K. T.; Krammer, M.; Manfredi, P. F.; Meier, D.; LeNormand; Pan, L. S.; Pernegger, H.; Pernicka, M.; Plano, R.; Re, V.; Riester, J. L.; Roe, S.; Roff; Rudge, A.; Schieber, M.; Schnetzer, S.; Sciortino, S.; Speziali, V.; Stelzer, H.; Stone, R.; Tapper, R. J.; Tesarek, R.; Thomson, G. B.; Trawick, M.; Trischuk, W.; Turchetta, R.; RD 42 Collaboration
1998-02-01
CVD diamond radiation sensors are being developed for possible use in trackers in the LHC experiments. The diamond promises to be radiation hard well beyond particle fluences that can be tolerated by Si sensors. Recent results from the RD 42 collaboration on charge collection distance and on radiation hardness of CVD diamond samples will be reported. Measurements with diamond tracking devices, both strip detectors and pixel detectors, will be discussed. Results from beam tests using a diamond strip detector which was read out with fast, 25 ns shaping time, radiation-hard pipeline electronics will be presented.
Wang, Xiandi; Zhang, Hanlu; Dong, Lin; Han, Xun; Du, Weiming; Zhai, Junyi; Pan, Caofeng; Wang, Zhong Lin
2016-04-20
A triboelectric sensor matrix (TESM) can accurately track and map 2D tactile sensing. A self-powered, high-resolution, pressure-sensitive, flexible and durable TESM with 16 × 16 pixels is fabricated for the fast detection of single-point and multi-point touching. Using cross-locating technology, a cross-type TESM with 32 × 20 pixels is developed for more rapid tactile mapping, which significantly reduces the addressing lines from m × n to m + n. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Singh, R. G.; Singh, Fouran; Kanjilal, D.; Agarwal, V.; Mehra, R. M.
2009-03-01
White light emission across the extended visible region of the electromagnetic spectrum from the ZnO-porous silicon (PS) nanocomposite is reported. Nanocrystallites of ZnO were grown inside the spongy structures of PS by the chemical route of sol-gel spin coating. The property of the material arises from versatile interactions among the host structures of PS and ZnO. The origin of the observed extended white light emission from 1.4 to 3.3 eV is discussed by developing a flat band energy diagram.
2017-09-01
neuropathic pain associated with chemotherapy. Moreover, our recent 7 work shows that targeting the S1P/S1PR1 axis by treatment with FTY720 greatly...reduces cancer-induced bone pain and neuroinflammation (Grenald et al., 2017) and supports potential fast-track clinical application of the FDA...approved drug, FTY720, as a therapeutic avenue for cancer-induced bone pain . 4.3. The Impact on Technology Transfer Nothing to report 4.4. The impact on
Towards an Optimal Interest Point Detector for Measurements in Ultrasound Images
NASA Astrophysics Data System (ADS)
Zukal, Martin; Beneš, Radek; Číka, Petr; Říha, Kamil
2013-12-01
This paper focuses on the comparison of different interest point detectors and their utilization for measurements in ultrasound (US) images. Certain medical examinations are based on speckle tracking which strongly relies on features that can be reliably tracked frame to frame. Only significant features (interest points) resistant to noise and brightness changes within US images are suitable for accurate long-lasting tracking. We compare three interest point detectors - Harris-Laplace, Difference of Gaussian (DoG) and Fast Hessian - and identify the most suitable one for use in US images on the basis of an objective criterion. Repeatability rate is assumed to be an objective quality measure for comparison. We have measured repeatability in images corrupted by different types of noise (speckle noise, Gaussian noise) and for changes in brightness. The Harris-Laplace detector outperformed its competitors and seems to be a sound option when choosing a suitable interest point detector for US images. However, it has to be noted that Fast Hessian and DoG detectors achieved better results in terms of processing speed.
Ge, Yuanyuan; O’Brien, Ricky T.; Shieh, Chun-Chien; Booth, Jeremy T.; Keall, Paul J.
2014-01-01
Purpose: Intrafraction deformation limits targeting accuracy in radiotherapy. Studies show tumor deformation of over 10 mm for both single tumor deformation and system deformation (due to differential motion between primary tumors and involved lymph nodes). Such deformation cannot be adapted to with current radiotherapy methods. The objective of this study was to develop and experimentally investigate the ability of a dynamic multi-leaf collimator (DMLC) tracking system to account for tumor deformation. Methods: To compensate for tumor deformation, the DMLC tracking strategy is to warp the planned beam aperture directly to conform to the new tumor shape based on real time tumor deformation input. Two deformable phantoms that correspond to a single tumor and a tumor system were developed. The planar deformations derived from the phantom images in beam's eye view were used to guide the aperture warping. An in-house deformable image registration software was developed to automatically trigger the registration once new target image was acquired and send the computed deformation to the DMLC tracking software. Because the registration speed is not fast enough to implement the experiment in real-time manner, the phantom deformation only proceeded to the next position until registration of the current deformation position was completed. The deformation tracking accuracy was evaluated by a geometric target coverage metric defined as the sum of the area incorrectly outside and inside the ideal aperture. The individual contributions from the deformable registration algorithm and the finite leaf width to the tracking uncertainty were analyzed. Clinical proof-of-principle experiment of deformation tracking using previously acquired MR images of a lung cancer patient was implemented to represent the MRI-Linac environment. Intensity-modulated radiation therapy (IMRT) treatment delivered with enabled deformation tracking was simulated and demonstrated. Results: The first experimental investigation of adapting to tumor deformation has been performed using simple deformable phantoms. For the single tumor deformation, the Au+Ao was reduced over 56% when deformation was larger than 2 mm. Overall, the total improvement was 82%. For the tumor system deformation, the Au+Ao reductions were all above 75% and the total Au+Ao improvement was 86%. Similar coverage improvement was also found in simulating deformation tracking during IMRT delivery. The deformable image registration algorithm was identified as the dominant contributor to the tracking error rather than the finite leaf width. The discrepancy between the warped beam shape and the ideal beam shape due to the deformable registration was observed to be partially compensated during leaf fitting due to the finite leaf width. The clinical proof-of-principle experiment demonstrated the feasibility of intrafraction deformable tracking for clinical scenarios. Conclusions: For the first time, we developed and demonstrated an experimental system that is capable of adapting the MLC aperture to account for tumor deformation. This work provides a potentially widely available management method to effectively account for intrafractional tumor deformation. This proof-of-principle study is the first experimental step toward the development of an image-guided radiotherapy system to treat deforming tumors in real-time. PMID:24877798
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ge, Yuanyuan; O’Brien, Ricky T.; Shieh, Chun-Chien
Purpose: Intrafraction deformation limits targeting accuracy in radiotherapy. Studies show tumor deformation of over 10 mm for both single tumor deformation and system deformation (due to differential motion between primary tumors and involved lymph nodes). Such deformation cannot be adapted to with current radiotherapy methods. The objective of this study was to develop and experimentally investigate the ability of a dynamic multi-leaf collimator (DMLC) tracking system to account for tumor deformation. Methods: To compensate for tumor deformation, the DMLC tracking strategy is to warp the planned beam aperture directly to conform to the new tumor shape based on real timemore » tumor deformation input. Two deformable phantoms that correspond to a single tumor and a tumor system were developed. The planar deformations derived from the phantom images in beam's eye view were used to guide the aperture warping. An in-house deformable image registration software was developed to automatically trigger the registration once new target image was acquired and send the computed deformation to the DMLC tracking software. Because the registration speed is not fast enough to implement the experiment in real-time manner, the phantom deformation only proceeded to the next position until registration of the current deformation position was completed. The deformation tracking accuracy was evaluated by a geometric target coverage metric defined as the sum of the area incorrectly outside and inside the ideal aperture. The individual contributions from the deformable registration algorithm and the finite leaf width to the tracking uncertainty were analyzed. Clinical proof-of-principle experiment of deformation tracking using previously acquired MR images of a lung cancer patient was implemented to represent the MRI-Linac environment. Intensity-modulated radiation therapy (IMRT) treatment delivered with enabled deformation tracking was simulated and demonstrated. Results: The first experimental investigation of adapting to tumor deformation has been performed using simple deformable phantoms. For the single tumor deformation, the A{sub u}+A{sub o} was reduced over 56% when deformation was larger than 2 mm. Overall, the total improvement was 82%. For the tumor system deformation, the A{sub u}+A{sub o} reductions were all above 75% and the total A{sub u}+A{sub o} improvement was 86%. Similar coverage improvement was also found in simulating deformation tracking during IMRT delivery. The deformable image registration algorithm was identified as the dominant contributor to the tracking error rather than the finite leaf width. The discrepancy between the warped beam shape and the ideal beam shape due to the deformable registration was observed to be partially compensated during leaf fitting due to the finite leaf width. The clinical proof-of-principle experiment demonstrated the feasibility of intrafraction deformable tracking for clinical scenarios. Conclusions: For the first time, we developed and demonstrated an experimental system that is capable of adapting the MLC aperture to account for tumor deformation. This work provides a potentially widely available management method to effectively account for intrafractional tumor deformation. This proof-of-principle study is the first experimental step toward the development of an image-guided radiotherapy system to treat deforming tumors in real-time.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Averyanov, A. V.; Bajajin, A. G.; Chepurnov, V. F.
The time-projection chamber (TPC) is the main tracking detector in the MPD/NICA. The information on charge-particle tracks in the TPC is registered by the MWPG with cathode pad readout. The frontend electronics (FEE) are developed with use of modern technologies such as application specific integrated circuits (ASIC), field-programmable gate arrays (FPGA), and data transfer to a concentrator via a fast optical interface. The main parameters of the FEE are as follows: total number of channels, ∼95 000; data stream from the whole TPC, 5 GB/s; low power consumption, less than 100 mW/ch; signal to noise ratio (S/N), 30; equivalent noisemore » charge (ENC), <1000e{sup –} (C{sub in} = 10–20 pF); and zero suppression (pad signal rejection ∼90%). The article presents the status of the readout chamber construction and the data acquisition system. The results of testing FEE prototypes are presented.« less
All-digital GPS receiver mechanization
NASA Astrophysics Data System (ADS)
Ould, P. C.; van Wechel, R. J.
The paper describes the all-digital baseband correlation processing of GPS signals, which is characterized by (1) a potential for improved antijamming performance, (2) fast acquisition by a digital matched filter, (3) reduction of adjustment, (4) increased system reliability, and (5) provision of a basis for the realization of a high degree of VLSI potential for the development of small economical GPS sets. The basic technical approach consists of a broadband fix-tuned RF converter followed by a digitizer; digital-matched-filter acquisition section; phase- and delay-lock tracking via baseband digital correlation; software acquisition logic and loop filter implementation; and all-digital implementation of the feedback numerical controlled oscillators and code generator. Broadband in-phase and quadrature tracking is performed by an arctangent angle detector followed by a phase-unwrapping algorithm that eliminates false locks induced by sampling and data bit transitions, and yields a wide pull-in frequency range approaching one-fourth of the loop iteration frequency.
Sivaramakrishnan, Shyam; Rajamani, Rajesh; Johnson, Bruce D
2009-01-01
Respiratory CO(2) measurement (capnography) is an important diagnosis tool that lacks inexpensive and wearable sensors. This paper develops techniques to enable use of inexpensive but slow CO(2) sensors for breath-by-breath tracking of CO(2) concentration. This is achieved by mathematically modeling the dynamic response and using model-inversion techniques to predict input CO(2) concentration from the slow-varying output. Experiments are designed to identify model-dynamics and extract relevant model-parameters for a solidstate room monitoring CO(2) sensor. A second-order model that accounts for flow through the sensor's filter and casing is found to be accurate in describing the sensor's slow response. The resulting estimate is compared with a standard-of-care respiratory CO(2) analyzer and shown to effectively track variation in breath-by-breath CO(2) concentration. This methodology is potentially useful for measuring fast-varying inputs to any slow sensor.
A simple backscattering microscope for fast tracking of biological molecules
Sowa, Yoshiyuki; Steel, Bradley C.; Berry, Richard M.
2010-01-01
Recent developments in techniques for observing single molecules under light microscopes have helped reveal the mechanisms by which molecular machines work. A wide range of markers can be used to detect molecules, from single fluorophores to micron sized markers, depending on the research interest. Here, we present a new and simple objective-type backscattering microscope to track gold nanoparticles with nanometer and microsecond resolution. The total noise of our system in a 55 kHz bandwidth is ∼0.6 nm per axis, sufficient to measure molecular movement. We found our backscattering microscopy to be useful not only for in vitro but also for in vivo experiments because of lower background scattering from cells than in conventional dark-field microscopy. We demonstrate the application of this technique to measuring the motion of a biological rotary molecular motor, the bacterial flagellar motor, in live Escherichia coli cells. PMID:21133475
NASA Astrophysics Data System (ADS)
Bal, A.; Alam, M. S.; Aslan, M. S.
2006-05-01
Often sensor ego-motion or fast target movement causes the target to temporarily go out of the field-of-view leading to reappearing target detection problem in target tracking applications. Since the target goes out of the current frame and reenters at a later frame, the reentering location and variations in rotation, scale, and other 3D orientations of the target are not known thus complicating the detection algorithm has been developed using Fukunaga-Koontz Transform (FKT) and distance classifier correlation filter (DCCF). The detection algorithm uses target and background information, extracted from training samples, to detect possible candidate target images. The detected candidate target images are then introduced into the second algorithm, DCCF, called clutter rejection module, to determine the target coordinates are detected and tracking algorithm is initiated. The performance of the proposed FKT-DCCF based target detection algorithm has been tested using real-world forward looking infrared (FLIR) video sequences.
NASA Astrophysics Data System (ADS)
Kharlamov, Petr; Dementev, Dmitrii; Shitenkov, Mikhail
2017-10-01
High-energy heavy-ion collision experiments provide the unique possibility to create and investigate extreme states of strongly-interacted matter and address the fundamental aspects of QCD. The experimental investigation the QCD phase diagram would be a major breakthrough in our understanding of the properties of nuclear matter. The reconstruction of the charged particles created in the nuclear collisions, including the determination of their momenta, is the central detection task in high-energy heavy-ion experiments. It is taken up by the Silicon Tracking System in CBM@FAIR and by Inner Tracker in MPD@NICA currently under development. These experiments requires very fast and radiation hard detectors, a novel data read-out and analysis concept including free streaming front-end electronics. Thermal and beam tests of prototype detector modules for these tracking systems showed the stability of sensors and readout electronics operation.
Video fingerprinting for copy identification: from research to industry applications
NASA Astrophysics Data System (ADS)
Lu, Jian
2009-02-01
Research that began a decade ago in video copy detection has developed into a technology known as "video fingerprinting". Today, video fingerprinting is an essential and enabling tool adopted by the industry for video content identification and management in online video distribution. This paper provides a comprehensive review of video fingerprinting technology and its applications in identifying, tracking, and managing copyrighted content on the Internet. The review includes a survey on video fingerprinting algorithms and some fundamental design considerations, such as robustness, discriminability, and compactness. It also discusses fingerprint matching algorithms, including complexity analysis, and approximation and optimization for fast fingerprint matching. On the application side, it provides an overview of a number of industry-driven applications that rely on video fingerprinting. Examples are given based on real-world systems and workflows to demonstrate applications in detecting and managing copyrighted content, and in monitoring and tracking video distribution on the Internet.
GEM detector performance with innovative micro-TPC readout in high magnetic field
NASA Astrophysics Data System (ADS)
Garzia, I.; Alexeev, M.; Amoroso, A.; Baldini Ferroli, R.; Bertani, M.; Bettoni, D.; Bianchi, F.; Calcaterra, A.; Canale, N.; Capodiferro, M.; Cassariti, V.; Cerioni, S.; Chai, J. Y.; Chiozzi, S.; Cibinetto, G.; Cossio, F.; Cotta Ramusino, A.; De Mori, F.; Destefanis, M.; Dong, J.; Evangelisti, F.; Evangelisti, F.; Farinelli, R.; Fava, L.; Felici, G.; Fioravanti, E.; Gatta, M.; Greco, M.; Lavezzi, L.; Leng, C. Y.; Li, H.; Maggiora, M.; Malaguti, R.; Marcello, S.; Melchiorri, M.; Mezzadri, G.; Mignone, M.; Morello, G.; Pacetti, S.; Patteri, P.; Pellegrino, J.; Pelosi, A.; Rivetti, A.; Rolo, M. D.; Savrié, M.; Scodeggio, M.; Soldani, E.; Sosio, S.; Spataro, S.; Tskhadadze, E.; Verma, S.; Wheadon, R.; Yan, L.
2018-01-01
Gas detector development is one of the pillars of the research in fundamental physics. Since several years, a new concept of detectors, called Micro Pattern Gas Detector (MPGD), allowed to overcome several problems related to other types of commonly used detectors, like drift chamber and micro strips detectors, reducing the rate of discharges and providing better radiation tolerance. Among the most used MPGDs are the Gas Electron Multipliers (GEMs). Invented by Sauli in 1997, nowadays GEMs have become an important reality for particle detectors in high energy physics. Commonly deployed as fast timing detectors and triggers, their fast response, high rate capability and high radiation hardness make them also suitable as tracking detectors. The readout scheme is one of the most important features in tracking technology. Analog readout based on the calculation of the center of gravity technique allows to overcome the limit imposed by digital pads, whose spatial resolution is limited by the pitch dimensions. However, the presence of high external magnetic fields can distort the electronic cloud and affect the performance. The development of the micro-TPC reconstruction method brings GEM detectors into a new prospective, improving significantly the spatial resolutionin presence of high magnetic fields. This innovative technique allows to reconstruct the 3-dimensional particle position, as Time Projection Chamber, but within a drift gap of a few millimeters. In these report, the charge centroid and micro-TPC methods are described in details. We discuss the results of several test beams performed with planar chambers in magnetic field. These results are one of the first developments of micro-TPC technique for GEM detectors, which allows to reach unprecedented performance in a high magnetic field of 1 T.
Visual object tracking by correlation filters and online learning
NASA Astrophysics Data System (ADS)
Zhang, Xin; Xia, Gui-Song; Lu, Qikai; Shen, Weiming; Zhang, Liangpei
2018-06-01
Due to the complexity of background scenarios and the variation of target appearance, it is difficult to achieve high accuracy and fast speed for object tracking. Currently, correlation filters based trackers (CFTs) show promising performance in object tracking. The CFTs estimate the target's position by correlation filters with different kinds of features. However, most of CFTs can hardly re-detect the target in the case of long-term tracking drifts. In this paper, a feature integration object tracker named correlation filters and online learning (CFOL) is proposed. CFOL estimates the target's position and its corresponding correlation score using the same discriminative correlation filter with multi-features. To reduce tracking drifts, a new sampling and updating strategy for online learning is proposed. Experiments conducted on 51 image sequences demonstrate that the proposed algorithm is superior to the state-of-the-art approaches.
Caracterización y automatización mecánica de los telescopios Cherenkov de CASLEO
NASA Astrophysics Data System (ADS)
Leal, N.; Yelós, L. D.; Mancilla, A.; Maya, J.; Feres, L.; Lazarte, F.; García, B.
2017-10-01
A new automation system for the Cherenkov Telescopes at CASLEO is designed. Two rotation speeds are proposed: a fast speed for positioning and parking and a slow speed for tracking. The wind speed at El Leoncito site is used as a design parameter. In this work we present the first tests with the new setup which shows a correct performance at fast speeds.
Tracking quasi-stationary flow of weak fluorescent signals by adaptive multi-frame correlation.
Ji, L; Danuser, G
2005-12-01
We have developed a novel cross-correlation technique to probe quasi-stationary flow of fluorescent signals in live cells at a spatial resolution that is close to single particle tracking. By correlating image blocks between pairs of consecutive frames and integrating their correlation scores over multiple frame pairs, uncertainty in identifying a globally significant maximum in the correlation score function has been greatly reduced as compared with conventional correlation-based tracking using the signal of only two consecutive frames. This approach proves robust and very effective in analysing images with a weak, noise-perturbed signal contrast where texture characteristics cannot be matched between only a pair of frames. It can also be applied to images that lack prominent features that could be utilized for particle tracking or feature-based template matching. Furthermore, owing to the integration of correlation scores over multiple frames, the method can handle signals with substantial frame-to-frame intensity variation where conventional correlation-based tracking fails. We tested the performance of the method by tracking polymer flow in actin and microtubule cytoskeleton structures labelled at various fluorophore densities providing imagery with a broad range of signal modulation and noise. In applications to fluorescent speckle microscopy (FSM), where the fluorophore density is sufficiently low to reveal patterns of discrete fluorescent marks referred to as speckles, we combined the multi-frame correlation approach proposed above with particle tracking. This hybrid approach allowed us to follow single speckles robustly in areas of high speckle density and fast flow, where previously published FSM analysis methods were unsuccessful. Thus, we can now probe cytoskeleton polymer dynamics in living cells at an entirely new level of complexity and with unprecedented detail.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hassan, T.A.
1992-12-01
The practical use of Pulsed Laser Velocimetry (PLV) requires the use of fast, reliable computer-based methods for tracking numerous particles suspended in a fluid flow. Two methods for performing tracking are presented. One method tracks a particle through multiple sequential images (minimum of four required) by prediction and verification of particle displacement and direction. The other method, requiring only two sequential images uses a dynamic, binary, spatial, cross-correlation technique. The algorithms are tested on computer-generated synthetic data and experimental data which was obtained with traditional PLV methods. This allowed error analysis and testing of the algorithms on real engineering flows.more » A novel method is proposed which eliminates tedious, undersirable, manual, operator assistance in removing erroneous vectors. This method uses an iterative process involving an interpolated field produced from the most reliable vectors. Methods are developed to allow fast analysis and presentation of sets of PLV image data. Experimental investigation of a two-phase, horizontal, stratified, flow regime was performed to determine the interface drag force, and correspondingly, the drag coefficient. A horizontal, stratified flow test facility using water and air was constructed to allow interface shear measurements with PLV techniques. The experimentally obtained local drag measurements were compared with theoretical results given by conventional interfacial drag theory. Close agreement was shown when local conditions near the interface were similar to space-averaged conditions. However, theory based on macroscopic, space-averaged flow behavior was shown to give incorrect results if the local gas velocity near the interface as unstable, transient, and dissimilar from the average gas velocity through the test facility.« less
Multiparticle imaging technique for two-phase fluid flows using pulsed laser speckle velocimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hassan, T.A.
1992-12-01
The practical use of Pulsed Laser Velocimetry (PLV) requires the use of fast, reliable computer-based methods for tracking numerous particles suspended in a fluid flow. Two methods for performing tracking are presented. One method tracks a particle through multiple sequential images (minimum of four required) by prediction and verification of particle displacement and direction. The other method, requiring only two sequential images uses a dynamic, binary, spatial, cross-correlation technique. The algorithms are tested on computer-generated synthetic data and experimental data which was obtained with traditional PLV methods. This allowed error analysis and testing of the algorithms on real engineering flows.more » A novel method is proposed which eliminates tedious, undersirable, manual, operator assistance in removing erroneous vectors. This method uses an iterative process involving an interpolated field produced from the most reliable vectors. Methods are developed to allow fast analysis and presentation of sets of PLV image data. Experimental investigation of a two-phase, horizontal, stratified, flow regime was performed to determine the interface drag force, and correspondingly, the drag coefficient. A horizontal, stratified flow test facility using water and air was constructed to allow interface shear measurements with PLV techniques. The experimentally obtained local drag measurements were compared with theoretical results given by conventional interfacial drag theory. Close agreement was shown when local conditions near the interface were similar to space-averaged conditions. However, theory based on macroscopic, space-averaged flow behavior was shown to give incorrect results if the local gas velocity near the interface as unstable, transient, and dissimilar from the average gas velocity through the test facility.« less
NASA Astrophysics Data System (ADS)
Cajgfinger, Thomas; Chabanat, Eric; Dominjon, Agnes; Doan, Quang T.; Guerin, Cyrille; Houles, Julien; Barbier, Remi
2011-03-01
Nano-biophotonics applications will benefit from new fluorescent microscopy methods based essentially on super-resolution techniques (beyond the diffraction limit) on large biological structures (membranes) with fast frame rate (1000 Hz). This trend tends to push the photon detectors to the single-photon counting regime and the camera acquisition system to real time dynamic multiple-target tracing. The LUSIPHER prototype presented in this paper aims to give a different approach than those of Electron Multiplied CCD (EMCCD) technology and try to answer to the stringent demands of the new nano-biophotonics imaging techniques. The electron bombarded CMOS (ebCMOS) device has the potential to respond to this challenge, thanks to the linear gain of the accelerating high voltage of the photo-cathode, to the possible ultra fast frame rate of CMOS sensors and to the single-photon sensitivity. We produced a camera system based on a 640 kPixels ebCMOS with its acquisition system. The proof of concept for single-photon based tracking for multiple single-emitters is the main result of this paper.
Fast Track to College Act of 2009
Rep. Kildee, Dale E. [D-MI-5
2009-03-18
House - 03/22/2010 Referred to the Subcommittee on Early Childhood, Elementary, and Secondary Education. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Avola, Danilo; Spezialetti, Matteo; Placidi, Giuseppe
2013-06-01
Rehabilitation is often required after stroke, surgery, or degenerative diseases. It has to be specific for each patient and can be easily calibrated if assisted by human-computer interfaces and virtual reality. Recognition and tracking of different human body landmarks represent the basic features for the design of the next generation of human-computer interfaces. The most advanced systems for capturing human gestures are focused on vision-based techniques which, on the one hand, may require compromises from real-time and spatial precision and, on the other hand, ensure natural interaction experience. The integration of vision-based interfaces with thematic virtual environments encourages the development of novel applications and services regarding rehabilitation activities. The algorithmic processes involved during gesture recognition activity, as well as the characteristics of the virtual environments, can be developed with different levels of accuracy. This paper describes the architectural aspects of a framework supporting real-time vision-based gesture recognition and virtual environments for fast prototyping of customized exercises for rehabilitation purposes. The goal is to provide the therapist with a tool for fast implementation and modification of specific rehabilitation exercises for specific patients, during functional recovery. Pilot examples of designed applications and preliminary system evaluation are reported and discussed. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Zhang, Dashan; Guo, Jie; Lei, Xiujun; Zhu, Changan
2016-04-22
The development of image sensor and optics enables the application of vision-based techniques to the non-contact dynamic vibration analysis of large-scale structures. As an emerging technology, a vision-based approach allows for remote measuring and does not bring any additional mass to the measuring object compared with traditional contact measurements. In this study, a high-speed vision-based sensor system is developed to extract structure vibration signals in real time. A fast motion extraction algorithm is required for this system because the maximum sampling frequency of the charge-coupled device (CCD) sensor can reach up to 1000 Hz. Two efficient subpixel level motion extraction algorithms, namely the modified Taylor approximation refinement algorithm and the localization refinement algorithm, are integrated into the proposed vision sensor. Quantitative analysis shows that both of the two modified algorithms are at least five times faster than conventional upsampled cross-correlation approaches and achieve satisfactory error performance. The practicability of the developed sensor is evaluated by an experiment in a laboratory environment and a field test. Experimental results indicate that the developed high-speed vision-based sensor system can extract accurate dynamic structure vibration signals by tracking either artificial targets or natural features.
Fast Track to College Act of 2011
Sen. Kohl, Herb [D-WI
2011-01-25
Senate - 01/25/2011 Read twice and referred to the Committee on Health, Education, Labor, and Pensions. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Fast Track to College Act of 2009
Sen. Kohl, Herb [D-WI
2009-03-18
Senate - 03/18/2009 Read twice and referred to the Committee on Health, Education, Labor, and Pensions. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Fast Track to College Act of 2014
Sen. Coons, Christopher A. [D-DE
2014-09-18
Senate - 09/18/2014 Read twice and referred to the Committee on Health, Education, Labor, and Pensions. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Zika Virus and Complications: Questions and Answers
... mosquito breeding sites, by emptying, cleaning or covering containers that can hold even small amounts of water, ... D community and regulators to fast-track the availability of effective diagnostic tests, vaccines and medicines that ...
Locational Sensitivity Investigation on PV Hosting Capacity and Fast Track PV Screening
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, Fei; Mather, Barry; Ainsworth, Nathan
A 15% PV penetration threshold is commonly used by utilities to define photovoltaic (PV) screening methods where PV penetration is defined as the ratio of total solar PV capacity on a line section to peak load. However, this method doesn't take into account PV locational impact or feeder characteristics that could strongly change the feeder's capability to host PVs. This paper investigates the impact of PV location and phase connection type on PV hosting capacity, and then proposes a fast-track PV screening approach that leverages various PV hosting capacity metric responding to different PV locations and types. The proposed studymore » could help utilities to evaluate PV interconnection requests and also help increase the PV hosting capacity of distribution feeders without adverse impacts on system voltages.« less
Initial Impact of the Fast Track Prevention Trial for Conduct Problems: I. The High-Risk Sample
2009-01-01
Fast Track is a multisite, multicomponent preventive intervention for young children at high risk for long-term antisocial behavior. Based on a comprehensive developmental model intervention included a universal-level classroom program plus social skills training, academic tutoring, parent training, and home visiting to improve competencies and reduce problems in a high-risk group of children selected in kindergarten. At the end of Grade 1, there were moderate positive effects on children's social, emotional, and academic skills; peer interactions and social status; and conduct problems and special-education use. Parents reported less-physical discipline and greater parenting satisfaction/ease of parenting and engaged in more appropriate/consistent discipline, warmth/positive involvement, and involvement with the school. Evidence of differential intervention effects across child gender, race, site, and cohort was minimal. PMID:10535230
[Leipzig fast-track protocol for cardio-anesthesia. Effective, safe and economical].
Häntschel, D; Fassl, J; Scholz, M; Sommer, M; Funkat, A K; Wittmann, M; Ender, J
2009-04-01
In November 2005 a complex, multimodal anesthesia fast-track protocol (FTP) was introduced for elective cardiac surgery patients in the Cardiac Center of the University of Leipzig which included changing from an opioid regime to remifentanil and postoperative treatment in a special post-anesthesia recovery and care unit. The goal was to speed up recovery times while maintaining safety and improving costs. A total of 421 patients who underwent the FTP and were treated in the special recovery room were analyzed retrospectively. These patients were compared with patients who had been treated by a standard protocol (SP) prior to instituting the FTP. Primary outcomes were time to extubation, length of stay in the intensive care unit (ICU) and treatment costs. The times to extubation were significantly shorter in the FTP group with 75 min (range 45-110 min) compared to 900 min (range 600-1140 min) in the SP group. Intensive care unit stay and hospital length of stay were also significantly shorter in the FTP group (p<0.01). The reduction of treatment costs of intensive care for FTP patients was 53.5% corresponding to savings of EUR 738 per patient in the FTP group compared with the SP group. The Leipzig fast-track protocol for cardio-anesthesia including the central elements of switching opiate therapy to remifentanil and switching patient recovery to a special post-anesthesia recovery and care unit, shortened therapy times, is safe and economically effective.
The design, status and performance of the ZEUS central tracking detector electronics
NASA Astrophysics Data System (ADS)
Cussans, D. G.; Fawcett, H. F.; Foster, B.; Gilmore, R. S.; Heath, G. P.; Llewellyn, T. J.; Malos, J.; Morgado, C. J. S.; Tapper, R. J.; Gingrich, D. M.; Harnew, N.; Hallam-Baker, P.; Nash, J.; Khatri, T.; Shield, P. D.; McArthur, I.; Topp-Jorgensen, S.; Wilson, F. F.; Allen, D.; Baird, S. A.; Carter, R.; Galagardera, S.; Gibson, M. D.; Hatley, R. S.; Jeffs, M.; Milborrow, R.; Morissey, M.; Quinton, S. P. H.; White, D. J.; Lane, J.; Nixon, G.; Postranecky, M.; Jamdagni, A. K.; Marcou, C.; Miller, D. B.; Toudup, L.
1992-05-01
The readout system developed for the ZEUS central trackign detector (CDT) is described. The CTD is required to provide an accurate measurement of the sagitta and energy loss of charged particles as well as provide fast trigger information. This must be carried out in the HERA environment in which beams cross every 96 ns. The first two aims are achieved by digitizing chamber pulses using a pipelined 104 MHz FADC system. The trigger uses a fast determination of the difference in the arrival times of a pulse at each end of the CTD. It processes this data and gives information to the ZEUS global first level trigger. The modules are housed in custom-built racks and crates and read out using a DAQ system based on Transputer readout controllers. These also monitor data quality and produce data for the ZEUS second level Trigger.
A novel Kalman filter based video image processing scheme for two-photon fluorescence microscopy
NASA Astrophysics Data System (ADS)
Sun, Wenqing; Huang, Xia; Li, Chunqiang; Xiao, Chuan; Qian, Wei
2016-03-01
Two-photon fluorescence microscopy (TPFM) is a perfect optical imaging equipment to monitor the interaction between fast moving viruses and hosts. However, due to strong unavoidable background noises from the culture, videos obtained by this technique are too noisy to elaborate this fast infection process without video image processing. In this study, we developed a novel scheme to eliminate background noises, recover background bacteria images and improve video qualities. In our scheme, we modified and implemented the following methods for both host and virus videos: correlation method, round identification method, tree-structured nonlinear filters, Kalman filters, and cell tracking method. After these procedures, most of noises were eliminated and host images were recovered with their moving directions and speed highlighted in the videos. From the analysis of the processed videos, 93% bacteria and 98% viruses were correctly detected in each frame on average.
Improvements in simulation of multiple scattering effects in ATLAS fast simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basalaev, A. E., E-mail: artem.basalaev@cern.ch
Fast ATLAS Tracking Simulation (Fatras) package was verified on single layer geometry with respect to full simulation with GEANT4. Fatras hadronic interactions and multiple scattering simulation were studied in comparison with GEANT4. Disagreement was found in multiple scattering distributions of primary charged particles (μ, π, e). A new model for multiple scattering simulation was implemented in Fatras. The model was based on R. Frühwirth’s mixture models. New model was tested on single layer geometry and a good agreement with GEANT4 was achieved. Also a comparison of reconstructed tracks’ parameters was performed for Inner Detector geometry, and Fatras with new multiplemore » scattering model proved to have better agreement with GEANT4. New model of multiple scattering was added as a part of Fatras package in the development release of ATLAS software—ATHENA.« less
Fast widely-tunable single-frequency 2-micron laser for remote-sensing applications
NASA Astrophysics Data System (ADS)
Henderson, Sammy W.; Hale, Charley P.
2017-08-01
We are developing a family of fast, widely-tunable cw diode-pumped single frequency solid-state lasers, called Swift. The Swift laser architecture is compatible with operation using many different solid-state laser crystals for operation at various emission lines between 1 and 2.1 micron. The initial prototype Swift laser using a Tm,Ho:YLF laser crystal near 2.05 micron wavelength achieved over 100 mW of single frequency cw output power, up to 50 GHz-wide, fast, mode-hop-free piezoelectric tunability, and 100 kHz/ms frequency stability. For the Tm,Ho:YLF laser material, the fast 50 GHz tuning range can be centered at any wavelength from 2047-2059 nm using appropriate intracavity spectral filters. The frequency stability and power are sufficient to serve as the local oscillator (LO) laser in long-range coherent wind-measuring lidar systems, as well as a frequency-agile master oscillator (MO) or injection-seed source for larger pulsed transmitter lasers. The rapid and wide frequency tunablity meets the requirements for integrated-path or range-resolved differential absorption lidar or applications where targets with significantly different line of sight velocities (Doppler shifts) must be tracked. Initial demonstration of an even more compact version of the Swift is also described which requires less prime power and produces less waste heat.
Anesthesia and fast-track in video-assisted thoracic surgery (VATS): from evidence to practice.
Umari, Marzia; Falini, Stefano; Segat, Matteo; Zuliani, Michele; Crisman, Marco; Comuzzi, Lucia; Pagos, Francesco; Lovadina, Stefano; Lucangelo, Umberto
2018-03-01
In thoracic surgery, the introduction of video-assisted thoracoscopic techniques has allowed the development of fast-track protocols, with shorter hospital lengths of stay and improved outcomes. The perioperative management needs to be optimized accordingly, with the goal of reducing postoperative complications and speeding recovery times. Premedication performed in the operative room should be wisely administered because often linked to late discharge from the post-anesthesia care unit (PACU). Inhalatory anesthesia, when possible, should be preferred based on protective effects on postoperative lung inflammation. Deep neuromuscular blockade should be pursued and carefully monitored, and an appropriate reversal administered before extubation. Management of one-lung ventilation (OLV) needs to be optimized to prevent not only intraoperative hypoxemia but also postoperative acute lung injury (ALI): protective ventilation strategies are therefore to be implemented. Locoregional techniques should be favored over intravenous analgesia: the thoracic epidural, the paravertebral block (PVB), the intercostal nerve block (ICNB), and the serratus anterior plane block (SAPB) are thoroughly reviewed and the most common dosages are reported. Fluid therapy needs to be administered critically, to avoid both overload and cardiovascular compromisation. All these practices are analyzed singularly with the aid of the most recent evidences aimed at the best patient care. Finally, a few notes on some of the latest trends in research are presented, such as non-intubated video-assisted thoracoscopic surgery (VATS) and intravenous lidocaine.
Anesthesia and fast-track in video-assisted thoracic surgery (VATS): from evidence to practice
Falini, Stefano; Segat, Matteo; Zuliani, Michele; Crisman, Marco; Comuzzi, Lucia; Pagos, Francesco; Lovadina, Stefano; Lucangelo, Umberto
2018-01-01
In thoracic surgery, the introduction of video-assisted thoracoscopic techniques has allowed the development of fast-track protocols, with shorter hospital lengths of stay and improved outcomes. The perioperative management needs to be optimized accordingly, with the goal of reducing postoperative complications and speeding recovery times. Premedication performed in the operative room should be wisely administered because often linked to late discharge from the post-anesthesia care unit (PACU). Inhalatory anesthesia, when possible, should be preferred based on protective effects on postoperative lung inflammation. Deep neuromuscular blockade should be pursued and carefully monitored, and an appropriate reversal administered before extubation. Management of one-lung ventilation (OLV) needs to be optimized to prevent not only intraoperative hypoxemia but also postoperative acute lung injury (ALI): protective ventilation strategies are therefore to be implemented. Locoregional techniques should be favored over intravenous analgesia: the thoracic epidural, the paravertebral block (PVB), the intercostal nerve block (ICNB), and the serratus anterior plane block (SAPB) are thoroughly reviewed and the most common dosages are reported. Fluid therapy needs to be administered critically, to avoid both overload and cardiovascular compromisation. All these practices are analyzed singularly with the aid of the most recent evidences aimed at the best patient care. Finally, a few notes on some of the latest trends in research are presented, such as non-intubated video-assisted thoracoscopic surgery (VATS) and intravenous lidocaine. PMID:29629201
Bižić, Marta R; Cvetinović, Nataša; Majstorović, Marko J; Radojčić, Zoran; Vukadinović, Vojkan; Krstić, Zoran; Djordjević, Miroslav L
2012-01-01
Urogenital congenital anomalies are among the most common congenital anomalies and very frequent pathology in paediatric urology. Health care systems strive to shorten the duration and reduce the costs of hospitalization, while maintaining treatment effectiveness. To evaluate the duration of hospital stay of surgically treated patients with congenital urogenital anomalies and estimate the possibility of using fast track surgery principles in paediatric urology in the local settings of a developing country. Retrospective non-randomized study included 552 patients who had been surgically treated at the Urology Department of the University Children's Hospital, during 2010. In line with their congenital anomalies, all patients were classified in one of four groups: I--upper urinary tract anomalies (252 patients); II--genital anomalies (164 patients); III--testicular anomalies (76 patients) and IV--associated anomalies (60 patients). We analyzed the total duration of stay as well as pre- and post-operative stay in the hospital. The average duration of hospitalization was 4.7 +/- 4.0 days. Patients with testicular anomalies stayed for the shortest period (2.3 +/- 1.9 days) (p < 0.01) and patients with associated anomalies stayed in the hospital the longest (6.5 +/- 4.7 days) (p < 0.01). Modern methods of surgical treatment allow reduction of hospitalization, financial savings to the healthcare system and greater comfort for patients. Our results showed that this is also possible to apply in our environment.
Fast, Capacious Disk Memory Device
NASA Technical Reports Server (NTRS)
Muller, Ronald M.
1990-01-01
Device for recording digital data on, and playing back data from, memory disks has high recording or playback rate and utilizes available recording area more fully. Two disks, each with own reading/writing head, used to record data at same time. Head on disk A operates on one of tracks numbered from outside in; head on disk B operates on track of same number in sequence from inside out. Underlying concept of device applicable to magnetic or optical disks.
NASA Astrophysics Data System (ADS)
Konacki, M.; Lejba, P.; Sybilski, P.; Pawłaszek, R.; Kozłowski, S.; Suchodolski, T.; Słonina, M.; Litwicki, M.; Sybilska, A.; Rogowska, B.; Kolb, U.; Burwitz, V.; Baader, J.; Groot, P.; Bloemen, S.; Ratajczak, M.; Hełminiak, K.; Borek, R.; Chodosiewicz, P.; Chimicz, A.
We present an update on the preparation of our assets that consists of a robotic network of eight optical telescopes and a laser ranging station for regular services in the SST domain. We report the development of new optical assets that include a double telescope system, Panoptes-1AB, and a new astrograph on our Solaris-3 telescope at the Siding Spring Observatory, Australia. Progress in the software development necessary for smooth SST operation includes a web based portal and an XML Azure Queue scheduling for the network giving easy access to our sensors. Astrometry24.net our new prototype cloud service for fast astrometry, streak detection and measurement with precision and performance results is also described. In the laser domain, for more than a year, Space Research Centre Borowiec laser station has regularly tracked space debris cooperative and uncooperative targets. The efforts of the stations’ staff have been focused on the tracking of typical rocket bodies from the LEO regime. Additionally, a second independent laser system fully dedicated to SST activities is under development. It will allow for an increased pace of operation of our consortium in the global SST laser domain.
FAST TRACK COMMUNICATION The Bel-Robinson tensor for topologically massive gravity
NASA Astrophysics Data System (ADS)
Deser, S.; Franklin, J.
2011-02-01
We construct, and establish the (covariant) conservation of, a 4-index 'super stress tensor' for topologically massive gravity. Separately, we discuss its invalidity in quadratic curvature models and suggest a generalization.
1999 Florida Freight Stakeholders Task Force Report
DOT National Transportation Integrated Search
1999-11-01
The Florida Freight Stakeholders Task Force was organized in 1998 as a result of the Governor's Transportation Summit to address two principal objectives: (1) to identify, prioritize and recommend freight transportation projects for fast track fundin...
Just Add Water and Stir. Graduate Chemistry Laboratory, Stony Brook
ERIC Educational Resources Information Center
Yee, Roger
1974-01-01
Using traditional building materials and a fast-track recipe, the architects, acting as construction manager, completed the Graduate Chemistry Laboratory at Stony Brook, New York, two full years ahead of schedule. (Author/MF)
Analysis of a spatial tracking subsystem for optical communications
NASA Technical Reports Server (NTRS)
Win, Moe Z.; Chen, CHIEN-C.
1992-01-01
Spatial tracking plays a very critical role in designing optical communication systems because of the small angular beamwidth associated with the optical signal. One possible solution for spatial tracking is to use a nutating mirror which dithers the incoming beam at a rate much higher than the mechanical disturbances. A power detector then senses the change in detected power as the signal is reflected off the nutating mirror. This signal is then correlated with the nutator driver signals to obtain estimates of the azimuth and elevation tracking signals to control the fast scanning mirrors. A theoretical analysis is performed for a spatial tracking system using a nutator disturbed by shot noise and mechanical vibrations. Contributions of shot noise and mechanical vibrations to the total tracking error variance are derived. Given the vibration spectrum and the expected signal power, there exists an optimal amplitude for the nutation which optimizes the receiver performance. The expected performance of a nutator based system is estimated based on the choice of nutation amplitude.
Convolutional networks for vehicle track segmentation
NASA Astrophysics Data System (ADS)
Quach, Tu-Thach
2017-10-01
Existing methods to detect vehicle tracks in coherent change detection images, a product of combining two synthetic aperture radar images taken at different times of the same scene, rely on simple and fast models to label track pixels. These models, however, are unable to capture natural track features, such as continuity and parallelism. More powerful but computationally expensive models can be used in offline settings. We present an approach that uses dilated convolutional networks consisting of a series of 3×3 convolutions to segment vehicle tracks. The design of our networks considers the fact that remote sensing applications tend to operate in low power and have limited training data. As a result, we aim for small and efficient networks that can be trained end-to-end to learn natural track features entirely from limited training data. We demonstrate that our six-layer network, trained on just 90 images, is computationally efficient and improves the F-score on a standard dataset to 0.992, up from 0.959 obtained by the current state-of-the-art method.
Nonlinear dynamics support a linear population code in a retinal target-tracking circuit.
Leonardo, Anthony; Meister, Markus
2013-10-23
A basic task faced by the visual system of many organisms is to accurately track the position of moving prey. The retina is the first stage in the processing of such stimuli; the nature of the transformation here, from photons to spike trains, constrains not only the ultimate fidelity of the tracking signal but also the ease with which it can be extracted by other brain regions. Here we demonstrate that a population of fast-OFF ganglion cells in the salamander retina, whose dynamics are governed by a nonlinear circuit, serve to compute the future position of the target over hundreds of milliseconds. The extrapolated position of the target is not found by stimulus reconstruction but is instead computed by a weighted sum of ganglion cell outputs, the population vector average (PVA). The magnitude of PVA extrapolation varies systematically with target size, speed, and acceleration, such that large targets are tracked most accurately at high speeds, and small targets at low speeds, just as is seen in the motion of real prey. Tracking precision reaches the resolution of single photoreceptors, and the PVA algorithm performs more robustly than several alternative algorithms. If the salamander brain uses the fast-OFF cell circuit for target extrapolation as we suggest, the circuit dynamics should leave a microstructure on the behavior that may be measured in future experiments. Our analysis highlights the utility of simple computations that, while not globally optimal, are efficiently implemented and have close to optimal performance over a limited but ethologically relevant range of stimuli.
NASA Astrophysics Data System (ADS)
Noh, M. J.; Howat, I. M.
2017-12-01
Glaciers and ice sheets are changing rapidly. Digital Elevation Models (DEMs) and Velocity Maps (VMs) obtained from repeat satellite imagery provide critical measurements of changes in glacier dynamics and mass balance over large, remote areas. DEMs created from stereopairs obtained during the same satellite pass through sensor re-pointing (i.e. "in-track stereo") have been most commonly used. In-track stereo has the advantage of minimizing the time separation and, thus, surface motion between image acquisitions, so that the ice surface can be assumed motionless in when collocating pixels between image pairs. Since the DEM extraction process assumes that all motion between collocated pixels is due to parallax or sensor model error, significant ice motion results in DEM quality loss or failure. In-track stereo, however, puts a greater demand on satellite tasking resources and, therefore, is much less abundant than single-scan imagery. Thus, if ice surface motion can be mitigated, the ability to extract surface elevation measurements from pairs of repeat single-scan "cross-track" imagery would greatly increase the extent and temporal resolution of ice surface change. Additionally, the ice motion measured by the DEM extraction process would itself provide a useful velocity measurement. We develop a novel algorithm for generating high-quality DEMs and VMs from cross-track image pairs without any prior information using the Surface Extraction from TIN-based Searchspace Minimization (SETSM) algorithm and its sensor model bias correction capabilities. Using a test suite of repeat, single-scan imagery from WorldView and QuickBird sensors collected over fast-moving outlet glaciers, we develop a method by which RPC biases between images are first calculated and removed over ice-free surfaces. Subpixel displacements over the ice are then constrained and used to correct the parallax estimate. Initial tests yield DEM results with the same quality as in-track stereo for cases where snowfall has not occurred between the two images and when the images have similar ground sample distances. The resulting velocity map also closely matches independent measurements.
Tang, Catherine; Russell, Pamela J; Martiniello-Wilks, Rosetta; J Rasko, John E; Khatri, Aparajita
2010-01-01
Ineffective treatment and poor patient management continue to plague the arena of clinical oncology. The crucial issues include inadequate treatment efficacy due to ineffective targeting of cancer deposits, systemic toxicities, suboptimal cancer detection and disease monitoring. This has led to the quest for clinically relevant, innovative multifaceted solutions such as development of targeted and traceable therapies. Mesenchymal stem cells (MSCs) have the intrinsic ability to “home” to growing tumors and are hypoimmunogenic. Therefore, these can be used as (a) “Trojan Horses” to deliver gene therapy directly into the tumors and (b) carriers of nanoparticles to allow cell tracking and simultaneous cancer detection. The camouflage of MSC carriers can potentially tackle the issues of safety, vector, and/or transgene immunogenicity as well as nanoparticle clearance and toxicity. The versatility of the nanotechnology platform could allow cellular tracking using single or multimodal imaging modalities. Toward that end, noninvasive magnetic resonance imaging (MRI) is fast becoming a clinical favorite, though there is scope for improvement in its accuracy and sensitivity. In that, use of superparamagnetic iron-oxide nanoparticles (SPION) as MRI contrast enhancers may be the best option for tracking therapeutic MSC. The prospects and consequences of synergistic approaches using MSC carriers, gene therapy, and SPION in developing cancer diagnostics and therapeutics are discussed. STEM CELLS 2010; 28:1686–1702. PMID:20629172
Data for development in health: a case study and monitoring framework from Kazakhstan
Obermann, Konrad; Chanturidze, Tata; Richardson, Erica; Tanirbergenov, Serik; Shoranov, Marat; Nurgozhaev, Ali
2016-01-01
Healthcare reforms are often not coupled with a relevant and appropriate monitoring framework, leaving policymakers and the public without evidence about the implications of such reforms. Kazakhstan has embarked on a large-scale reform of its healthcare system in order to achieve Universal Health Coverage. The health-related 2020 Strategic Development Goals reflect this political ambition. In a case-study approach and on the basis of published and unpublished evidence as well as personal involvement and experience (A) the indicators in the 2020 Strategic Development Goals were assessed and (B) a ‘data-mapping’ exercise was conducted, where the WHO health system framework was used to describe the data available at present in Kazakhstan and comment on the different indicators regarding their usefulness for monitoring the current health-related 2020 Strategic Development Goals in Kazakhstan. It was concluded that the country’s current monitoring framework needs further development to track the progress and outcomes of policy implementation. The application of a modified WHO/World Bank/Global Fund health system monitoring framework was suggested to examine the implications of recent health sector reforms. Lessons drawn from the Kazakhstan experience on tailoring the suggested framework, collecting the data, and using the generated intelligence in policy development and decision-making can serve as a useful example for other middle-income countries, potentially enabling them to fast-track developments in the health sector. PMID:28588905
Track Everything: Limiting Prior Knowledge in Online Multi-Object Recognition.
Wong, Sebastien C; Stamatescu, Victor; Gatt, Adam; Kearney, David; Lee, Ivan; McDonnell, Mark D
2017-10-01
This paper addresses the problem of online tracking and classification of multiple objects in an image sequence. Our proposed solution is to first track all objects in the scene without relying on object-specific prior knowledge, which in other systems can take the form of hand-crafted features or user-based track initialization. We then classify the tracked objects with a fast-learning image classifier, that is based on a shallow convolutional neural network architecture and demonstrate that object recognition improves when this is combined with object state information from the tracking algorithm. We argue that by transferring the use of prior knowledge from the detection and tracking stages to the classification stage, we can design a robust, general purpose object recognition system with the ability to detect and track a variety of object types. We describe our biologically inspired implementation, which adaptively learns the shape and motion of tracked objects, and apply it to the Neovision2 Tower benchmark data set, which contains multiple object types. An experimental evaluation demonstrates that our approach is competitive with the state-of-the-art video object recognition systems that do make use of object-specific prior knowledge in detection and tracking, while providing additional practical advantages by virtue of its generality.
Impact of reproductive health on socio-economic development: a case study of Nigeria.
Adinma, J I B; Adinma, E D
2011-03-01
The link between reproductive health, sexual and reproductive right, and development was highlighted at the International Conference on Population and Development held in Egypt. Developmental disparities are related to socio-economic differences which have led to the identification of distinct socio-economic classifications of nations. Human development represents the socioeconomic standing of any nation, in addition to literacy status and life expectancy. Africa accounts for 25% of the world's landmass but remains the world's poorest continent. Nigeria, the most populous country in Africa, has policies and programmes geared towards the improvement of its socio-economic standing and overal development, with little positive result. Reproductive health is a panacea towards reversing the stalled socio-economic growth of Nigeria as evident from the linkage between reproductive health and development, highlighted in Millennium Development Goals 3, 4, 5 and 6. Fast tracking Nigeria's development requires implementation of reproductive health policies and programmes targeted on women and children.
A fast and complete GEANT4 and ROOT Object-Oriented Toolkit: GROOT
NASA Astrophysics Data System (ADS)
Lattuada, D.; Balabanski, D. L.; Chesnevskaya, S.; Costa, M.; Crucillà, V.; Guardo, G. L.; La Cognata, M.; Matei, C.; Pizzone, R. G.; Romano, S.; Spitaleri, C.; Tumino, A.; Xu, Y.
2018-01-01
Present and future gamma-beam facilities represent a great opportunity to validate and evaluate the cross-sections of many photonuclear reactions at near-threshold energies. Monte Carlo (MC) simulations are very important to evaluate the reaction rates and to maximize the detection efficiency but, unfortunately, they can be very cputime-consuming and in some cases very hard to reproduce, especially when exploring near-threshold cross-section. We developed a software that makes use of the validated tracking GEANT4 libraries and the n-body event generator of ROOT in order to provide a fast, realiable and complete MC tool to be used for nuclear physics experiments. This tool is indeed intended to be used for photonuclear reactions at γ-beam facilities with ELISSA (ELI Silicon Strip Array), a new detector array under development at the Extreme Light Infrastructure - Nuclear Physics (ELI-NP). We discuss the results of MC simulations performed to evaluate the effects of the electromagnetic induced background, of the straggling due to the target thickness and of the resolution of the silicon detectors.
Dynamic grid refinement for partial differential equations on parallel computers
NASA Technical Reports Server (NTRS)
Mccormick, S.; Quinlan, D.
1989-01-01
The fast adaptive composite grid method (FAC) is an algorithm that uses various levels of uniform grids to provide adaptive resolution and fast solution of PDEs. An asynchronous version of FAC, called AFAC, that completely eliminates the bottleneck to parallelism is presented. This paper describes the advantage that this algorithm has in adaptive refinement for moving singularities on multiprocessor computers. This work is applicable to the parallel solution of two- and three-dimensional shock tracking problems.
Simplified fast neutron dosimeter
Sohrabi, Mehdi
1979-01-01
Direct fast-neutron-induced recoil and alpha particle tracks in polycarbonate films may be enlarged for direct visual observation and automated counting procedures employing electrochemical etching techniques. Electrochemical etching is, for example, carried out in a 28% KOH solution at room temperature by applying a 2000 V peak-to-peak voltage at 1 kHz frequency. Such recoil particle amplification can be used for the detection of wide neutron dose ranges from 1 mrad. to 1000 rads. or higher, if desired.
2015-03-01
Through the use of a sophisticated modeling technique, investigators at the University of Cincinnati have found that the creation of a so-called "flex track" that includes beds that can be assigned to either high-acuity or Iow-acuity- patients has the potential to lower mean wait times for patients when it is i added to the traditional fast-track and high-acuity areas of a 50-bed ED that sees 85,000 patients per year. Investigators used discrete-event simulation to model the patient flow and characteristics of the ED at the University of Cincinnati Medical Center, and to test out various operational scenarios without disrupting real-world operations. The investigators concluded that patient wait times were lowest when three flex beds were appropriated from the 10-bed fast track area of the EDs. In light of the results, three flex rooms are being incorporated into a newly remodeled ED scheduled for completion laterthis spring. Investigators suggest the modeling technique could be useful to other EDs interested in optimizing their operational plans. Further, they suggest that ED administrators consider ways to introduce flexibility into departments that are now more rigidly divided between high- and low-acuity areas.
NASA Astrophysics Data System (ADS)
Parracino, Stefano; Santoro, Simone; Maio, Giovanni; Nuvoli, Marcello; Aiuppa, Alessandro; Fiorani, Luca
2017-04-01
Carbon dioxide (CO2) is considered a precursor gas of volcanic eruptions by volcanologists. Monitoring the anomalous release of this parameter, we can retrieve useful information for the mitigation of volcanic hazards, such as for air traffic security. From a dataset collected during the Stromboli volcano field campaign, an assessment of the wind speed, in both horizontal and vertical paths, performing a fast tracking of this parameter was retrieved. This was determined with a newly designed shot-per-shot differential absorption LiDAR system operated in the near-infrared spectral region due to the simultaneous reconstruction of CO2 concentrations and wind speeds, using the same sample of LiDAR returns. A correlation method was used for the wind speed retrieval in which the transport of the spatial inhomogeneities of the aerosol backscattering coefficient, along the optical path of the system, was analyzed.
Fast cine-magnetic resonance imaging point tracking for prostate cancer radiation therapy planning
NASA Astrophysics Data System (ADS)
Dowling, J.; Dang, K.; Fox, Chris D.; Chandra, S.; Gill, Suki; Kron, T.; Pham, D.; Foroudi, F.
2014-03-01
The analysis of intra-fraction organ motion is important for improving the precision of radiation therapy treatment delivery. One method to quantify this motion is for one or more observers to manually identify anatomic points of interest (POIs) on each slice of a cine-MRI sequence. However this is labour intensive and inter- and intra- observer variation can introduce uncertainty. In this paper a fast method for non-rigid registration based point tracking in cine-MRI sagittal and coronal series is described which identifies POIs in 0.98 seconds per sagittal slice and 1.35 seconds per coronal slice. The manual and automatic points were highly correlated (r>0.99, p<0.001) for all organs and the difference generally less than 1mm. For prostate planning peristalsis and rectal gas can result in unpredictable out of plane motion, suggesting the results may require manual verification.
Health Preemption Behind Closed Doors: Trade Agreements and Fast-Track Authority
Crosbie, Eric; Gonzalez, Mariaelena
2014-01-01
Noncommunicable diseases result from consuming unhealthy products, including tobacco, which are promoted by transnational corporations. The tobacco industry uses preemption to block or reverse tobacco control policies. Preemption removes authority from jurisdictions where tobacco companies’ influence is weak and transfers it to jurisdictions where they have an advantage. International trade agreements relocate decisions about tobacco control policy to venues where there is little opportunity for public scrutiny, participation, and debate. Tobacco companies are using these agreements to preempt domestic authority over tobacco policy. Other transnational corporations that profit by promoting unhealthy foods could do the same. “Fast-track authority,” in which Congress cedes ongoing oversight authority to the President, further distances the public from the debate. With international agreements binding governments to prioritize trade over health, transparency and public oversight of the trade negotiation process is necessary to safeguard public health interests. PMID:25033124
Potential Application of a Graphical Processing Unit to Parallel Computations in the NUBEAM Code
NASA Astrophysics Data System (ADS)
Payne, J.; McCune, D.; Prater, R.
2010-11-01
NUBEAM is a comprehensive computational Monte Carlo based model for neutral beam injection (NBI) in tokamaks. NUBEAM computes NBI-relevant profiles in tokamak plasmas by tracking the deposition and the slowing of fast ions. At the core of NUBEAM are vector calculations used to track fast ions. These calculations have recently been parallelized to run on MPI clusters. However, cost and interlink bandwidth limit the ability to fully parallelize NUBEAM on an MPI cluster. Recent implementation of double precision capabilities for Graphical Processing Units (GPUs) presents a cost effective and high performance alternative or complement to MPI computation. Commercially available graphics cards can achieve up to 672 GFLOPS double precision and can handle hundreds of thousands of threads. The ability to execute at least one thread per particle simultaneously could significantly reduce the execution time and the statistical noise of NUBEAM. Progress on implementation on a GPU will be presented.
Health preemption behind closed doors: trade agreements and fast-track authority.
Crosbie, Eric; Gonzalez, Mariaelena; Glantz, Stanton A
2014-09-01
Noncommunicable diseases result from consuming unhealthy products, including tobacco, which are promoted by transnational corporations. The tobacco industry uses preemption to block or reverse tobacco control policies. Preemption removes authority from jurisdictions where tobacco companies' influence is weak and transfers it to jurisdictions where they have an advantage. International trade agreements relocate decisions about tobacco control policy to venues where there is little opportunity for public scrutiny, participation, and debate. Tobacco companies are using these agreements to preempt domestic authority over tobacco policy. Other transnational corporations that profit by promoting unhealthy foods could do the same. "Fast-track authority," in which Congress cedes ongoing oversight authority to the President, further distances the public from the debate. With international agreements binding governments to prioritize trade over health, transparency and public oversight of the trade negotiation process is necessary to safeguard public health interests.
Electric eels use high-voltage to track fast-moving prey
Catania, Kenneth C.
2015-01-01
Electric eels (Electrophorus electricus) are legendary for their ability to incapacitate fish, humans, and horses with hundreds of volts of electricity. The function of this output as a weapon has been obvious for centuries but its potential role for electroreception has been overlooked. Here it is shown that electric eels use high-voltage simultaneously as a weapon and for precise and rapid electrolocation of fast-moving prey and conductors. Their speed, accuracy, and high-frequency pulse rate are reminiscent of bats using a ‘terminal feeding buzz' to track insects. Eel's exhibit ‘sensory conflict' when mechanosensory and electrosensory cues are separated, striking first toward mechanosensory cues and later toward conductors. Strikes initiated in the absence of conductors are aborted. In addition to providing new insights into the evolution of strongly electric fish and showing electric eels to be far more sophisticated than previously described, these findings reveal a trait with markedly dichotomous functions. PMID:26485580
TH-AB-202-04: Auto-Adaptive Margin Generation for MLC-Tracked Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glitzner, M; Lagendijk, J; Raaymakers, B
Purpose: To develop an auto-adaptive margin generator for MLC tracking. The generator is able to estimate errors arising in image guided radiotherapy, particularly on an MR-Linac, which depend on the latencies of machine and image processing, as well as on patient motion characteristics. From the estimated error distribution, a segment margin is generated, able to compensate errors up to a user-defined confidence. Method: In every tracking control cycle (TCC, 40ms), the desired aperture D(t) is compared to the actual aperture A(t), a delayed and imperfect representation of D(t). Thus an error e(t)=A(T)-D(T) is measured every TCC. Applying kernel-density-estimation (KDE), themore » cumulative distribution (CDF) of e(t) is estimated. With CDF-confidence limits, upper and lower error limits are extracted for motion axes along and perpendicular leaf-travel direction and applied as margins. To test the dosimetric impact, two representative motion traces were extracted from fast liver-MRI (10Hz). The traces were applied onto a 4D-motion platform and continuously tracked by an Elekta Agility 160 MLC using an artificially imposed tracking delay. Gafchromic film was used to detect dose exposition for static, tracked, and error-compensated tracking cases. The margin generator was parameterized to cover 90% of all tracking errors. Dosimetric impact was rated by calculating the ratio between underexposed points (>5% underdosage) to the total number of points inside FWHM of static exposure. Results: Without imposing adaptive margins, tracking experiments showed a ratio of underexposed points of 17.5% and 14.3% for two motion cases with imaging delays of 200ms and 300ms, respectively. Activating the margin generated yielded total suppression (<1%) of underdosed points. Conclusion: We showed that auto-adaptive error compensation using machine error statistics is possible for MLC tracking. The error compensation margins are calculated on-line, without the need of assuming motion or machine models. Further strategies to reduce consequential overdosages are currently under investigation. This work was funded by the SoRTS consortium, which includes the industry partners Elekta, Philips and Technolution.« less
An Improved Perturb and Observe Algorithm for Photovoltaic Motion Carriers
NASA Astrophysics Data System (ADS)
Peng, Lele; Xu, Wei; Li, Liming; Zheng, Shubin
2018-03-01
An improved perturbation and observation algorithm for photovoltaic motion carriers is proposed in this paper. The model of the proposed algorithm is given by using Lambert W function and tangent error method. Moreover, by using matlab and experiment of photovoltaic system, the tracking performance of the proposed algorithm is tested. And the results demonstrate that the improved algorithm has fast tracking speed and high efficiency. Furthermore, the energy conversion efficiency by the improved method has increased by nearly 8.2%.
Proportional plus integral MIMO controller for regulation and tracking with anti-wind-up features
DOE Office of Scientific and Technical Information (OSTI.GOV)
Puleston, P.F.; Mantz, R.J.
1993-11-01
A proportional plus integral matrix control structure for MIMO systems is proposed. Based on a standard optimal control structure with integral action, it permits a greater degree of independence of the design and tuning of the regulating and tracking features, without considerably increasing the controller complexity. Fast recovery from load disturbances is achieved, while large overshoots associated with set-point changes and reset wind-up problems can be reduced. A simple effective procedure for practical tuning is introduced.
Human ethology: age and sex differences in mall walking.
Hangland, A; Cimbalo, R S
1997-12-01
Well-controlled experimental research has examined the biomechanical aspects of walking in homo sapiens on a track. The research reported here also examined cadence, velocity, and stride length for estimated ages ranging from 15 to over 55 years but in a shopping mall. Women at all ages walked faster than men in the mall setting which was opposite to what was found in the track research. Apparently context may influence how fast people walk. Hunter-gatherer differences could explain these results.
Towards Kilo-Hertz 6-DoF Visual Tracking Using an Egocentric Cluster of Rolling Shutter Cameras.
Bapat, Akash; Dunn, Enrique; Frahm, Jan-Michael
2016-11-01
To maintain a reliable registration of the virtual world with the real world, augmented reality (AR) applications require highly accurate, low-latency tracking of the device. In this paper, we propose a novel method for performing this fast 6-DOF head pose tracking using a cluster of rolling shutter cameras. The key idea is that a rolling shutter camera works by capturing the rows of an image in rapid succession, essentially acting as a high-frequency 1D image sensor. By integrating multiple rolling shutter cameras on the AR device, our tracker is able to perform 6-DOF markerless tracking in a static indoor environment with minimal latency. Compared to state-of-the-art tracking systems, this tracking approach performs at significantly higher frequency, and it works in generalized environments. To demonstrate the feasibility of our system, we present thorough evaluations on synthetically generated data with tracking frequencies reaching 56.7 kHz. We further validate the method's accuracy on real-world images collected from a prototype of our tracking system against ground truth data using standard commodity GoPro cameras capturing at 120 Hz frame rate.
NASA Astrophysics Data System (ADS)
Kubes, P.; Paduch, M.; Sadowski, M. J.; Cikhardt, J.; Cikhardtova, B.; Klir, D.; Kravarik, J.; Munzar, V.; Rezac, K.; Zielinska, E.; Skladnik-Sadowska, E.; Szymaszek, A.; Tomaszewski, K.; Zaloga, D.
2018-01-01
This paper considers regions of a fast deuteron production in a correlation with an evolution of ordered structures inside a pinch column of a mega-ampere plasma focus discharge. Ion pinhole cameras equipped with plastic PM-355 track-detectors recorded fast deuterons escaping in the downstream and other directions (up to 60° to the z-axis). Time-integrated ion images made it possible to estimate sources of the deuteron acceleration at the known magnetic field and deuteron energy values. The images of the fast deuterons emitted in the solid angle ranging from 0° to 4° showed two forms: central spots and circular images. The spots of 1-2 cm in diameter were produced by deuterons from the central pinch regions. The circular-shaped images of a radius above 3 cm (or their parts) were formed by deuterons from the region surrounding the dense pinch column. The ion pinhole cameras placed at angles above 20° to the z-axis recorded the ion spots only, and the ring-images were missing. The central region of the deuteron acceleration could be associated mainly with plasmoids, and the circular images could be connected with ring-shaped regions of the radius corresponding to tops of the plasma lobules outside the dense pinch column. The deuteron tracks forming ring-shaped images of a smaller (0.5-1) cm radius could be produced by deflections of the fast deuterons, which were caused by a magnetic field inside the dense pinch column.
Dogan, Kemal; Kraaij, Linda; Aarts, Edo O; Koehestanie, Parweez; Hammink, Edwin; van Laarhoven, Cees J H M; Aufenacker, Theo J; Janssen, Ignace M C; Berends, Frits J
2015-01-01
Due to the increased incidence of morbid obesity, the demand for bariatric surgery is increasing. Therefore, the methods for optimising perioperative care for the improvement of surgical outcome and to increase efficacy are necessary. The aim of this prospective matched cohort study is to objectify the effect of the fast-track surgery (FTS) programme in patients undergoing primary Laparoscopic Roux-en-Y Gastric Bypass (LRYGB) surgery compared to conventional perioperative care (CPC). This study compared the perioperative outcome data of two groups of 75 consecutive morbid obese patients who underwent a primary LRYGB according to international guidelines in the periods January 2011-April 2011 (CPC group) and April 2012-June 2012 (FTS group). The two groups were matched for age and sex. Primary endpoints were surgery and hospitalisation time, while secondary endpoints were intraoperative medication use and complication rates. Baseline patient characteristics for age, sex, weight and ASA classification were similar (p > 0.05) for CPC and FTS patients. BMI and waist circumference were significantly lower (p < 0.05) in the FTS compared to CPC. The total time from arrival at the operating room to the arrival at the recovery was reduced from 119 to 82 min (p < 0.001). Surgery time was reduced from 80 to 56 min (p < 0.001); mean hospital stay was reduced from 65 to 43 h (p < 0.001). Major complications occurred in 3 versus 4 % in the FTS and CPC, respectively. The introduction of a fast-track programme after primary LRYGB improves short-term recovery and may reduces direct hospital-related resources.
Health-related quality of life and postoperative recovery in fast-track hysterectomy.
Wodlin, Ninnie Borendal; Nilsson, Lena; Kjølhede, Preben
2011-04-01
To determine whether health-related quality of life (HRQoL) and postoperative recovery of women who undergo abdominal hysterectomy in a fast-track program under general anesthesia (GA) differ from women who receive spinal anesthesia with intrathecal morphine (SA). Secondary analysis from an open randomized controlled multicenter study. Five hospitals in south-east Sweden. One hundred and eighty women admitted for abdominal hysterectomy for benign disease were randomized; 162 completed the study, 80 with GA and 82 with SA. The HRQoL was measured preoperatively using the EuroQoL EQ-5D and the Short-Form-36 health survey (SF-36) questionnaires. The EQ-5D was used daily for 1 week; thereafter, once weekly for 4 weeks and again 6 months after operation. The SF-36 was completed at 5 weeks and 6 months. Dates of commencing and ending sick leave were registered. Changes in HRQoL; duration of sick leave. The HRQoL improved significantly faster in women after SA than after GA. Sick leave was significantly shorter after SA than after GA (median 22.5 vs. 28 days). Recovery of HRQoL and duration of sick leave were negatively influenced by postoperative complications. In particular, the mental component of HRQoL was negatively affected by minor complications, even 6 months after the operation. Spinal anesthesia with intrathecal morphine provided substantial advantages in fast-track abdominal hysterectomy for benign gynecological disorders by providing faster recovery and shorter sick leave compared with general anesthesia. © 2011 The Authors Acta Obstetricia et Gynecologica Scandinavica© 2011 Nordic Federation of Societies of Obstetrics and Gynecology.
Ottesen, Marianne; Sørensen, Mette; Rasmussen, Yvonne; Smidt-Jensen, Steen; Kehlet, Henrik; Ottesen, Bent
2002-02-01
Our aim was to describe the need for postoperative hospitalization after vaginal surgery for utero-vaginal prolapse with well-defined charts for postoperative care. A prospective, descriptive study. Consecutive women admitted for first-time vaginal surgery for utero-vaginal prolapse at a public university hospital in Copenhagen, Denmark, underwent surgery and postoperative care in a fast track setting from September 15, 1999 to June 15 2000. A multimodal rehabilitation model with emphasis on information, standardized general anesthesia, reduced surgical distress, optimized pain-relief, early oral nutrition and ambulation, minimal use of indwelling catheter and vaginal packing. Postoperative hospital stay, complications, re-admission, success rate, patients' satisfaction and acceptability. Forty-one women with a median age of 69 years (range, 44-88 years) were included. All underwent anterior and/or posterior vaginal repair. Nineteen (46.3%) underwent vaginal hysterectomy, and eight (19.5%) underwent the Manchester procedure. Postoperative hospital stay was median 24 hr. Only three (7.3%) were discharged later than 48 hr. No re-admissions occurred. The most frequent complications were urinary retention exceeding 450 ml, and urinary tract infection (12.2%, and 9.8%, respectively). Short-term success rate was 97.6%. Patients' satisfaction rates were 85.4-95.1%. The median score of acceptability was 10 on a 0-10 points scale. The need for postoperative hospitalization was median 24 hr after vaginal surgery in a fast track setting, independently of the complexity of the procedure performed. Short-term success rate, satisfaction rates, and acceptability were all excellent. Follow up has been established to evaluate long-term success rates and recurrence.
NASA Astrophysics Data System (ADS)
Zhang, Qun; Yang, Yanfu; Xiang, Qian; Zhou, Zhongqing; Yao, Yong
2018-02-01
A joint compensation scheme based on cascaded Kalman filter is proposed, which can implement polarization tracking, channel equalization, frequency offset, and phase noise compensation simultaneously. The experimental results show that the proposed algorithm can not only compensate multiple channel impairments simultaneously but also improve the polarization tracking capacity and accelerate the convergence speed. The scheme has up to eight times faster convergence speed compared with radius-directed equalizer (RDE) + Max-FFT (maximum fast Fourier transform) + BPS (blind phase search) and can track up polarization rotation 60 times and 15 times faster than that of RDE + Max-FFT + BPS and CMMA (cascaded multimodulus algorithm) + Max-FFT + BPS, respectively.
Novel technique for tracking manpower and work packages: a useful tool for the team and management
NASA Astrophysics Data System (ADS)
Gill, R.; Gracia, G.; Lupton, R. H.; O'Mullane, W.
2014-08-01
In these times of austerity it is becoming more and more important to justify the need for manpower to management. Additionally, with the fast pace of today's projects the need for tools that facilitate teams to not only plan, but also track their work, are essential. The practice of planning work packages and the associated manpower has been about for a while but little is done to really cross-check that planning against reality. In this paper these elements are brought together through a number of tools that make up the end to end process of planning, tracking and reporting of work package progress and manpower usage.
Fire flame detection based on GICA and target tracking
NASA Astrophysics Data System (ADS)
Rong, Jianzhong; Zhou, Dechuang; Yao, Wei; Gao, Wei; Chen, Juan; Wang, Jian
2013-04-01
To improve the video fire detection rate, a robust fire detection algorithm based on the color, motion and pattern characteristics of fire targets was proposed, which proved a satisfactory fire detection rate for different fire scenes. In this fire detection algorithm: (a) a rule-based generic color model was developed based on analysis on a large quantity of flame pixels; (b) from the traditional GICA (Geometrical Independent Component Analysis) model, a Cumulative Geometrical Independent Component Analysis (C-GICA) model was developed for motion detection without static background and (c) a BP neural network fire recognition model based on multi-features of the fire pattern was developed. Fire detection tests on benchmark fire video clips of different scenes have shown the robustness, accuracy and fast-response of the algorithm.
NASA Astrophysics Data System (ADS)
Thangavelautham, J.; Asphaug, E.; Schwartz, S.
2017-02-01
Our work has identified the use of on-orbit centrifuge science laboratories as a key enabler towards low-cost, fast-track physical simulation of off-world environments for future planetary science missions.
76 FR 70225 - Advisory Council to the Internal Revenue Service; Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-10
... hereby given pursuant to section 10(a) (2) of the Federal Advisory Committee Act, 5 U.S.C. App. (1988), a..., Empower Exam Managers as an Alternative to SBSE Fast Track Settlement Program, Enhance Worker...
ERIC Educational Resources Information Center
Dolan, Thomas G.
2002-01-01
Describes Clark County, Nevada's use of prototype school designs to respond to its rapidly growing school population. The purpose of the prototypes is to simplify designs so that schools can be built quickly and minimize the time and expense that comes with variations. (EV)
Cognitive dysfunction after fast-track hip and knee replacement.
Krenk, Lene; Kehlet, Henrik; Bæk Hansen, Torben; Solgaard, Søren; Soballe, Kjeld; Rasmussen, Lars Simon
2014-05-01
Postoperative cognitive dysfunction (POCD) is reported to occur after major surgery in as many as 20% of patients, elderly patients may especially experience problems in the weeks and months after surgery. Recent studies vary greatly in methods of evaluation and diagnosis of POCD, and the pathogenic mechanisms are still unclear. We evaluated a large uniform cohort of elderly patients in a standardized approach, after major joint replacement surgery (total hip and knee replacement). Patients were in an optimized perioperative approach (fast track) with multimodal opioid-sparing analgesia, early mobilization, and short length of stay (LOS ≤3 days) and discharged to home. In a prospective multicenter study, we included 225 patients aged ≥60 years undergoing well-defined fast-track total hip or total knee replacement. Patients had neuropsychological testing preoperatively and 1 to 2 weeks and 3 months postoperatively. LOS, pain, opioid use, inflammatory response, and sleep quality were recorded. The practice effect of repeated cognitive testing was gauged using data from a healthy community-dwelling control group (n = 161). Median LOS was 2 days (interquartile range 2-3). The incidence of POCD at 1 to 2 weeks was 9.1% (95% confidence interval [CI], 5.4%-13.1%) and 8.0% (95% CI, 4.5%-12.0%) at 3 months. There was no statistically significant difference between patients with and without early POCD, regarding pain, opioid use, sleep quality, or C-reactive protein response, although the CIs were wide. Patients with early POCD had a higher Mini Mental State Examination score preoperatively (difference in medians 0.5 [95% CI, -1.0% to 0.0%]; P = 0.034). If there was an association between early POCD and late POCD, the sample size was unfortunately too small to verify this (23.6% of patients with early POCD had late onset vs 6.7% in non-POCD group; risk difference 16.9 (95% CI, -2.1% to 41.1%; P = 0.089). The incidence of POCD early after total hip and knee replacement seems to be lower after a fast-track approach than rates previously reported for these procedures, but late POCD occurred with an incidence similar to that in previous studies of major noncardiac elective surgery. No association between early and late POCD could be verified.
Three-dimensional liver motion tracking using real-time two-dimensional MRI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brix, Lau, E-mail: lau.brix@stab.rm.dk; Ringgaard, Steffen; Sørensen, Thomas Sangild
2014-04-15
Purpose: Combined magnetic resonance imaging (MRI) systems and linear accelerators for radiotherapy (MR-Linacs) are currently under development. MRI is noninvasive and nonionizing and can produce images with high soft tissue contrast. However, new tracking methods are required to obtain fast real-time spatial target localization. This study develops and evaluates a method for tracking three-dimensional (3D) respiratory liver motion in two-dimensional (2D) real-time MRI image series with high temporal and spatial resolution. Methods: The proposed method for 3D tracking in 2D real-time MRI series has three steps: (1) Recording of a 3D MRI scan and selection of a blood vessel (ormore » tumor) structure to be tracked in subsequent 2D MRI series. (2) Generation of a library of 2D image templates oriented parallel to the 2D MRI image series by reslicing and resampling the 3D MRI scan. (3) 3D tracking of the selected structure in each real-time 2D image by finding the template and template position that yield the highest normalized cross correlation coefficient with the image. Since the tracked structure has a known 3D position relative to each template, the selection and 2D localization of a specific template translates into quantification of both the through-plane and in-plane position of the structure. As a proof of principle, 3D tracking of liver blood vessel structures was performed in five healthy volunteers in two 5.4 Hz axial, sagittal, and coronal real-time 2D MRI series of 30 s duration. In each 2D MRI series, the 3D localization was carried out twice, using nonoverlapping template libraries, which resulted in a total of 12 estimated 3D trajectories per volunteer. Validation tests carried out to support the tracking algorithm included quantification of the breathing induced 3D liver motion and liver motion directionality for the volunteers, and comparison of 2D MRI estimated positions of a structure in a watermelon with the actual positions. Results: Axial, sagittal, and coronal 2D MRI series yielded 3D respiratory motion curves for all volunteers. The motion directionality and amplitude were very similar when measured directly as in-plane motion or estimated indirectly as through-plane motion. The mean peak-to-peak breathing amplitude was 1.6 mm (left-right), 11.0 mm (craniocaudal), and 2.5 mm (anterior-posterior). The position of the watermelon structure was estimated in 2D MRI images with a root-mean-square error of 0.52 mm (in-plane) and 0.87 mm (through-plane). Conclusions: A method for 3D tracking in 2D MRI series was developed and demonstrated for liver tracking in volunteers. The method would allow real-time 3D localization with integrated MR-Linac systems.« less
Terminal Sliding Mode Tracking Controller Design for Automatic Guided Vehicle
NASA Astrophysics Data System (ADS)
Chen, Hongbin
2018-03-01
Based on sliding mode variable structure control theory, the path tracking problem of automatic guided vehicle is studied, proposed a controller design method based on the terminal sliding mode. First of all, through analyzing the characteristics of the automatic guided vehicle movement, the kinematics model is presented. Then to improve the traditional expression of terminal sliding mode, design a nonlinear sliding mode which the convergence speed is faster than the former, verified by theoretical analysis, the design of sliding mode is steady and fast convergence in the limited time. Finally combining Lyapunov method to design the tracking control law of automatic guided vehicle, the controller can make the automatic guided vehicle track the desired trajectory in the global sense as well as in finite time. The simulation results verify the correctness and effectiveness of the control law.
Helmel, Michaela; Marchetti-Deschmann, Martina; Raus, Martin; Posch, Andreas E; Herwig, Christoph; Šebela, Marek; Allmaier, Günter
2015-02-01
Penicillin production during a fermentation process using industrial strains of Penicillium chrysogenum is a research topic permanently discussed since the accidental discovery of the antibiotic. Intact cell mass spectrometry (ICMS) can be a fast and novel monitoring tool for the fermentation progress during penicillin V production in a nearly real-time fashion. This method is already used for the characterization of microorganisms and the differentiation of fungal strains; therefore, the application of ICMS to samples directly harvested from a fermenter is a promising possibility to get fast information about the progress of fungal growth. After the optimization of the ICMS method to penicillin V fermentation broth samples, the obtained ICMS data were evaluated by hierarchical cluster analysis or an in-house software solution written especially for ICMS data comparison. Growth stages of a batch and fed-batch fermentation of Penicillium chrysogenum are differentiated by one of those statistical approaches. The application of two matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) instruments in the linear positive ion mode from different vendors demonstrated the universal applicability of the developed ICMS method. The base for a fast and easy-to-use method for monitoring the fermentation progress of P. chrysogenum is created with this ICMS method developed especially for fermentation broth samples. Copyright © 2014 Elsevier Inc. All rights reserved.
Fast algorithm for probabilistic bone edge detection (FAPBED)
NASA Astrophysics Data System (ADS)
Scepanovic, Danilo; Kirshtein, Joshua; Jain, Ameet K.; Taylor, Russell H.
2005-04-01
The registration of preoperative CT to intra-operative reality systems is a crucial step in Computer Assisted Orthopedic Surgery (CAOS). The intra-operative sensors include 3D digitizers, fiducials, X-rays and Ultrasound (US). FAPBED is designed to process CT volumes for registration to tracked US data. Tracked US is advantageous because it is real time, noninvasive, and non-ionizing, but it is also known to have inherent inaccuracies which create the need to develop a framework that is robust to various uncertainties, and can be useful in US-CT registration. Furthermore, conventional registration methods depend on accurate and absolute segmentation. Our proposed probabilistic framework addresses the segmentation-registration duality, wherein exact segmentation is not a prerequisite to achieve accurate registration. In this paper, we develop a method for fast and automatic probabilistic bone surface (edge) detection in CT images. Various features that influence the likelihood of the surface at each spatial coordinate are combined using a simple probabilistic framework, which strikes a fair balance between a high-level understanding of features in an image and the low-level number crunching of standard image processing techniques. The algorithm evaluates different features for detecting the probability of a bone surface at each voxel, and compounds the results of these methods to yield a final, low-noise, probability map of bone surfaces in the volume. Such a probability map can then be used in conjunction with a similar map from tracked intra-operative US to achieve accurate registration. Eight sample pelvic CT scans were used to extract feature parameters and validate the final probability maps. An un-optimized fully automatic Matlab code runs in five minutes per CT volume on average, and was validated by comparison against hand-segmented gold standards. The mean probability assigned to nonzero surface points was 0.8, while nonzero non-surface points had a mean value of 0.38 indicating clear identification of surface points on average. The segmentation was also sufficiently crisp, with a full width at half maximum (FWHM) value of 1.51 voxels.
Note: Fast neutron efficiency in CR-39 nuclear track detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cavallaro, S.
2015-03-15
CR-39 samples are commonly employed for fast neutron detection in fusion reactors and in inertial confinement fusion experiments. The literature reported efficiencies are strongly depending on experimental conditions and, in some cases, highly dispersed. The present note analyses the dependence of efficiency as a function of various parameters and experimental conditions in both the radiator-assisted and the stand-alone CR-39 configurations. Comparisons of literature experimental data with Monte Carlo calculations and optimized efficiency values are shown and discussed.
An avian model for the reversal of neurobehavioral teratogenicity with neural stem cells
Dotan, Sharon; Pinkas, Adi; Slotkin, Theodore A.; Yanai, Joseph
2010-01-01
A fast and simple model which uses lower animals on the evolutionary scale is beneficial for developing procedures for the reversal of neurobehavioral teratogenicity with neural stem cells. Here, we established a procedure for the derivation of chick neural stem cells, establishing embryonic day (E) 10 as optimal for progression to neuronal phenotypes. Cells were obtained from the embryonic cerebral hemispheres and incubated for 5–7 days in enriched medium containing epidermal growth factor (EGF) and basic fibroblast growth factor (FGF2) according to a procedure originally developed for mice. A small percentage of the cells survived, proliferated and formed nestin-positive neurospheres. After removal of the growth factors to allow differentiation (5 days), 74% of the cells differentiated into all major lineages of the nervous system, including neurons (Beta III tubulin-positive, 54% of the total number of differentiated cells), astrocytes (GFAP-positive, 26%), and oligodendrocytes (O4-positive, 20%). These findings demonstrate that the cells were indeed neural stem cells. Next, the cells were transplanted in two allograft chick models; (1) direct cerebral transplantation to 24-hours-old chicks, followed by post-transplantation cell tracking at 24 hours, 6 days and 14 days, and (2) intravenous transplantation to chick embryos on E13, followed by cell tracking on E19. With both methods, transplanted cells were found in the brain. The chick embryo provides a convenient, precisely-timed and unlimited supply of neural progenitors for therapy by transplantation, as well as constituting a fast and simple model in which to evaluate the ability of neural stem cell transplantation to repair neural damage, steps that are critical for progress toward therapeutic applications. PMID:20211723
Super-resolution imaging applied to moving object tracking
NASA Astrophysics Data System (ADS)
Swalaganata, Galandaru; Ratna Sulistyaningrum, Dwi; Setiyono, Budi
2017-10-01
Moving object tracking in a video is a method used to detect and analyze changes that occur in an object that being observed. Visual quality and the precision of the tracked target are highly wished in modern tracking system. The fact that the tracked object does not always seem clear causes the tracking result less precise. The reasons are low quality video, system noise, small object, and other factors. In order to improve the precision of the tracked object especially for small object, we propose a two step solution that integrates a super-resolution technique into tracking approach. First step is super-resolution imaging applied into frame sequences. This step was done by cropping the frame in several frame or all of frame. Second step is tracking the result of super-resolution images. Super-resolution image is a technique to obtain high-resolution images from low-resolution images. In this research single frame super-resolution technique is proposed for tracking approach. Single frame super-resolution was a kind of super-resolution that it has the advantage of fast computation time. The method used for tracking is Camshift. The advantages of Camshift was simple calculation based on HSV color that use its histogram for some condition and color of the object varies. The computational complexity and large memory requirements required for the implementation of super-resolution and tracking were reduced and the precision of the tracked target was good. Experiment showed that integrate a super-resolution imaging into tracking technique can track the object precisely with various background, shape changes of the object, and in a good light conditions.
Robust visual object tracking with interleaved segmentation
NASA Astrophysics Data System (ADS)
Abel, Peter; Kieritz, Hilke; Becker, Stefan; Arens, Michael
2017-10-01
In this paper we present a new approach for tracking non-rigid, deformable objects by means of merging an on-line boosting-based tracker and a fast foreground background segmentation. We extend an on-line boosting- based tracker, which uses axes-aligned bounding boxes with fixed aspect-ratio as tracking states. By constructing a confidence map from the on-line boosting-based tracker and unifying this map with a confidence map, which is obtained from a foreground background segmentation algorithm, we build a superior confidence map. For constructing a rough confidence map of a new frame based on on-line boosting, we employ the responses of the strong classifier as well as the single weak classifier responses that were built before during the updating step. This confidence map provides a rough estimation of the object's position and dimension. In order to refine this confidence map, we build a fine, pixel-wisely segmented confidence map and merge both maps together. Our segmentation method is color-histogram-based and provides a fine and fast image segmentation. By means of back-projection and the Bayes' rule, we obtain a confidence value for every pixel. The rough and the fine confidence maps are merged together by building an adaptively weighted sum of both maps. The weights are obtained by utilizing the variances of both confidence maps. Further, we apply morphological operators in the merged confidence map in order to reduce the noise. In the resulting map we estimate the object localization and dimension via continuous adaptive mean shift. Our approach provides a rotated rectangle as tracking states, which enables a more precise description of non-rigid, deformable objects than axes-aligned bounding boxes. We evaluate our tracker on the visual object tracking (VOT) benchmark dataset 2016.