Ender, Joerg; Borger, Michael Andrew; Scholz, Markus; Funkat, Anne-Kathrin; Anwar, Nadeem; Sommer, Marcus; Mohr, Friedrich Wilhelm; Fassl, Jens
2008-07-01
The authors compared the safety and efficacy of a newly developed fast-track concept at their center, including implementation of a direct admission postanesthetic care unit, to standard perioperative management. All fast-track patients treated within the first 6 months of implementation of our direct admission postanesthetic care unit were matched via propensity scores and compared with a historical control group of patients who underwent cardiac surgery prior to fast-track implementation. A total of 421 fast-track patients were matched successfully to 421 control patients. The two groups of patients had a similar age (64 +/- 13 vs. 64 +/- 12 yr for fast-track vs. control, P = 0.45) and European System for Cardiac Operative Risk Evaluation-predicted risk of mortality (4.8 +/- 6.1% vs. 4.6 +/- 5.1%, P = 0.97). Fast-track patients had significantly shorter times to extubation (75 min [45-110] vs. 900 min [600-1140]), as well as shorter lengths of stay in the postanesthetic or intensive care unit (4 h [3.0-5] vs. 20 h [16-25]), intermediate care unit (21 h [17-39] vs. 26 h [19-49]), and hospital (10 days [8-12] vs. 11 days [9-14]) (expressed as median and interquartile range, all P < 0.01). Fast-track patients also had a lower risk of postoperative low cardiac output syndrome (0.5% vs. 2.9%, P < 0.05) and mortality (0.5% vs. 3.3%, P < 0.01). The Leipzig fast-track protocol is a safe and effective method to manage cardiac surgery patients after a variety of operations.
Pacing Behavior and Tactical Positioning in 500- and 1000-m Short-Track Speed Skating.
Noorbergen, Olaf S; Konings, Marco J; Micklewright, Dominic; Elferink-Gemser, Marije T; Hettinga, Florentina J
2016-09-01
To explore pacing behavior and tactical positioning during the shorter 500- and 1000-m short-track competitions. Lap times and intermediate rankings of elite 500- and 1000-m short-track-skating competitors were collected over the 2012-13 season. First, lap times were analyzed using a MANOVA, and for each lap, differences between sex, race type, final ranking, and stage of competition were determined. Second, Kendall tau-b correlations were used to assess relationships between intermediate and final rankings. In addition, intermediate rankings of the winner of each race were examined. Top-placed athletes appeared faster than bottom-placed athletes in every lap in the 500-m, while in the 1000-m no differences were found until the final 4 laps (P < .05). Correlations between intermediate and final rankings were already high at the beginning stages of the 50-m (lap 1: r = .59) but not for the 1000-m (lap 1: r = .21). Although 500- and 1000-m short-track races are both relatively short, fundamental differences in pacing behavior and tactical positioning were found. A fast-start strategy seems to be optimal for 500-m races, while the crucial segment in 1000-m races seems to be from the 6th lap to the finish line (ie, after ± 650 m). These findings provide evidence to suggest that athletes balance between choosing an energetically optimal profile and the tactical and positional benefits that play a role when riding against an opponent, as well as contributing to developing novel insights in exploring athletic behavior when racing against opponents.
Pacing Behavior and Tactical Positioning in 1500-m Short-Track Speed Skating.
Konings, Marco J; Noorbergen, Olaf S; Parry, David; Hettinga, Florentina J
2016-01-01
To gain more insight in pacing behavior and tactical positioning in 1500-m short-track speed skating, a sport in which several athletes directly compete in the same race. Lap times and intermediate rankings of elite 1500-m short-track- skating competitors were collected over the season 2012-13 (N = 510, 85 races). Two statistical approaches were used to assess pacing behavior and tactical positioning. First, lap times were analyzed using a MANOVA, and for each lap differences between sex, race type, final rankings, and stage of competition were determined. Second, Kendall tau b correlations were used to assess relationships between intermediate and final rankings. In addition, intermediate rankings of the winner of each race were examined. In 1500 m (13.5 laps of 111.12 m), correlations between intermediate and final ranking gradually increased throughout the race (eg, lap 1, r = .05; lap 7, r = .26; lap 13, r = .85). Moreover, the percentage of race winners skating in the leading position was over 50% during the last 3 laps. Top finishers were faster than bottom-place finishers only during the last 5 laps, with on average 0.1- to 1.5-s faster lap times of the race winners compared with the others during the last 5 laps. Although a fast start led to faster finishing times, top finishers were faster than bottom-placed finishers only during the last 5 laps. Moreover, tactical positioning at 1 of the foremost positions during the latter phase of the race appeared to be a strong determinant of finishing position.
The nature of massive transition galaxies in CANDELS, GAMA and cosmological simulations
NASA Astrophysics Data System (ADS)
Pandya, Viraj; Brennan, Ryan; Somerville, Rachel S.; Choi, Ena; Barro, Guillermo; Wuyts, Stijn; Taylor, Edward N.; Behroozi, Peter; Kirkpatrick, Allison; Faber, Sandra M.; Primack, Joel; Koo, David C.; McIntosh, Daniel H.; Kocevski, Dale; Bell, Eric F.; Dekel, Avishai; Fang, Jerome J.; Ferguson, Henry C.; Grogin, Norman; Koekemoer, Anton M.; Lu, Yu; Mantha, Kameswara; Mobasher, Bahram; Newman, Jeffrey; Pacifici, Camilla; Papovich, Casey; van der Wel, Arjen; Yesuf, Hassen M.
2017-12-01
We explore observational and theoretical constraints on how galaxies might transition between the 'star-forming main sequence' (SFMS) and varying 'degrees of quiescence' out to z = 3. Our analysis is focused on galaxies with stellar mass M* > 1010 M⊙, and is enabled by GAMA and CANDELS observations, a semi-analytic model (SAM) of galaxy formation, and a cosmological hydrodynamical 'zoom in' simulation with momentum-driven AGN feedback. In both the observations and the SAM, transition galaxies tend to have intermediate Sérsic indices, half-light radii, and surface stellar mass densities compared to star-forming and quiescent galaxies out to z = 3. We place an observational upper limit on the average population transition time-scale as a function of redshift, finding that the average high-redshift galaxy is on a 'fast track' for quenching whereas the average low-redshift galaxy is on a 'slow track' for quenching. We qualitatively identify four physical origin scenarios for transition galaxies in the SAM: oscillations on the SFMS, slow quenching, fast quenching, and rejuvenation. Quenching time-scales in both the SAM and the hydrodynamical simulation are not fast enough to reproduce the quiescent population that we observe at z ∼ 3. In the SAM, we do not find a clear-cut morphological dependence of quenching time-scales, but we do predict that the mean stellar ages, cold gas fractions, SMBH (supermassive black hole) masses and halo masses of transition galaxies tend to be intermediate relative to those of star-forming and quiescent galaxies at z < 3.
ERIC Educational Resources Information Center
Sworder, Steven C.
2007-01-01
An experimental two-track intermediate algebra course was offered at Saddleback College, Mission Viejo, CA, between the Fall, 2002 and Fall, 2005 semesters. One track was modeled after the existing traditional California community college intermediate algebra course and the other track was a less rigorous intermediate algebra course in which the…
Philp, Shannon; Carter, J; Barnett, C; DʼAbrew, N; Pather, S; White, K
2015-01-01
This study examines the role of the fast-track nurse in gynecology from a patient perspective. The fast-track nurse is a specialist nursing role, which coordinates patient care, in addition to providing specialized clinical care. Semistructured interviews were conducted with women who had fast-track surgery for gynecological cancer.
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2012 CFR
2012-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires expeditious resolution. Fast Track procedures may include expedited...
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2011 CFR
2011-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires expeditious resolution. Fast Track procedures may include expedited...
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2010 CFR
2010-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires expeditious resolution. Fast Track procedures may include expedited...
40 CFR 72.82 - Fast-track modifications.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Fast-track modifications. 72.82... (CONTINUED) PERMITS REGULATION Permit Revisions § 72.82 Fast-track modifications. The following procedures shall apply to all fast-track modifications. (a) If the Administrator is the permitting authority, the...
40 CFR 72.82 - Fast-track modifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Fast-track modifications. 72.82... (CONTINUED) PERMITS REGULATION Permit Revisions § 72.82 Fast-track modifications. The following procedures shall apply to all fast-track modifications. (a) If the Administrator is the permitting authority, the...
40 CFR 72.82 - Fast-track modifications.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Fast-track modifications. 72.82... (CONTINUED) PERMITS REGULATION Permit Revisions § 72.82 Fast-track modifications. The following procedures shall apply to all fast-track modifications. (a) If the Administrator is the permitting authority, the...
40 CFR 72.82 - Fast-track modifications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Fast-track modifications. 72.82... (CONTINUED) PERMITS REGULATION Permit Revisions § 72.82 Fast-track modifications. The following procedures shall apply to all fast-track modifications. (a) If the Administrator is the permitting authority, the...
40 CFR 72.82 - Fast-track modifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Fast-track modifications. 72.82... (CONTINUED) PERMITS REGULATION Permit Revisions § 72.82 Fast-track modifications. The following procedures shall apply to all fast-track modifications. (a) If the Administrator is the permitting authority, the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-13
...: Fast Track Drug Development Programs: Designation, Development, and Application Review AGENCY: Food and... licenses for fast track designation as provided in the guidance for industry on fast track drug development... appropriate, and other forms of information technology. Guidance for Industry: Fast Track Drug Development...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lepekhin, F. G., E-mail: lepfed@yandex.ru; Tkach, L. N.
2011-05-15
Transverse-momentum distributions of doubly charged fragments of sulfur and lead nuclei having energies of 200 and 160 GeV per nucleon and interacting with nuclei in a track emulsion were investigated. No trace of compression or heating of nuclear matter in the interaction of these nuclei with track-emulsion nuclei was revealed experimentally. Transverse momenta of fragments of relativistic nuclei were found to obey a normal distribution that corresponds to a degenerate momentum distribution of nucleons in the ground state of a nucleus before its interaction with a track-emulsion nucleus. There is no piece of evidence that fragments of relativistic nuclei originatemore » from some excited state of an intermediate nucleus. This picture of the fragmentation of relativistic nuclei complies with the naive parton model proposed by Feynman and Gribov. In summary, the fragmentation of relativistic nuclei at energies of 160 and 200 GeV per nucleon is cold and fast.« less
42 CFR 422.626 - Fast-track appeals of service terminations to independent review entities (IREs).
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 3 2013-10-01 2013-10-01 false Fast-track appeals of service terminations to... ADVANTAGE PROGRAM Grievances, Organization Determinations and Appeals § 422.626 Fast-track appeals of service terminations to independent review entities (IREs). (a) Enrollee's right to a fast-track appeal of...
42 CFR 422.626 - Fast-track appeals of service terminations to independent review entities (IREs).
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 3 2012-10-01 2012-10-01 false Fast-track appeals of service terminations to... ADVANTAGE PROGRAM Grievances, Organization Determinations and Appeals § 422.626 Fast-track appeals of service terminations to independent review entities (IREs). (a) Enrollee's right to a fast-track appeal of...
42 CFR 422.626 - Fast-track appeals of service terminations to independent review entities (IREs).
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 3 2014-10-01 2014-10-01 false Fast-track appeals of service terminations to... ADVANTAGE PROGRAM Grievances, Organization Determinations and Appeals § 422.626 Fast-track appeals of service terminations to independent review entities (IREs). (a) Enrollee's right to a fast-track appeal of...
NASA Astrophysics Data System (ADS)
Dimiduk, D.; Caylor, M.; Williamson, D.; Larson, L.
1995-01-01
The High Altitude Balloon Experiment demonstration of Acquisition, Tracking, and Pointing (HABE-ATP) is a system built around balloon-borne payload which is carried to a nominal 26-km altitude. The goal is laser tracking thrusting theater and strategic missiles, and then pointing a surrogate laser weapon beam, with performance levels end a timeline traceable to operational laser weapon system requirements. This goal leads to an experiment system design which combines hardware from many technology areas: an optical telescope and IR sensors; an advanced angular inertial reference; a flexible multi-level of actuation digital control system; digital tracking processors which incorporate real-time image analysis and a pulsed, diode-pumped solid state tracking laser. The system components have been selected to meet the overall experiment goals of tracking unmodified boosters at 50- 200 km range. The ATP system on HABE must stabilize and control a relative line of sight between the platform and the unmodified target booster to a 1 microrad accuracy. The angular pointing reference system supports both open loop and closed loop track modes; GPS provides absolute position reference. The control system which positions the line of sight for the ATP system must sequence through accepting a state vector handoff, closed-loop passive IR acquisition, passive IR intermediate fine track, active fine track, and then finally aimpoint determination and maintenance modes. Line of sight stabilization to fine accuracy levels is accomplished by actuating wide bandwidth fast steering mirrors (FSM's). These control loops off-load large-amplitude errors to the outer gimbal in order to remain within the limited angular throw of the FSM's. The SWIR acquisition and MWIR intermediate fine track sensors (both PtSi focal planes) image the signature of the rocket plume. After Hard Body Handover (HBHO), active fine tracking is conducted with a visible focal plane viewing the laser-illuminated target rocket body. The track and fire control performance must be developed to the point that an aimpoint can be selected, maintained, and then track performance scored with a low-power 'surrogate' weapon beam. Extensive instrumentation monitors not only the optical sensors and the video data, but all aspects of each of the experiment subsystems such as the control system, the experiment flight vehicle, and the tracker. Because the system is balloon-borne and recoverable, it is expected to fly many times during its development program.
42 CFR 422.626 - Fast-track appeals of service terminations to independent review entities (IREs).
Code of Federal Regulations, 2010 CFR
2010-10-01
... Grievances, Organization Determinations and Appeals § 422.626 Fast-track appeals of service terminations to independent review entities (IREs). (a) Enrollee's right to a fast-track appeal of an MA organization's termination decision. An enrollee of an MA organization has a right to a fast-track appeal of an MA...
42 CFR 422.626 - Fast-track appeals of service terminations to independent review entities (IREs).
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 3 2011-10-01 2011-10-01 false Fast-track appeals of service terminations to... Grievances, Organization Determinations and Appeals § 422.626 Fast-track appeals of service terminations to independent review entities (IREs). (a) Enrollee's right to a fast-track appeal of an MA organization's...
Binding Isotherms and Time Courses Readily from Magnetic Resonance.
Xu, Jia; Van Doren, Steven R
2016-08-16
Evidence is presented that binding isotherms, simple or biphasic, can be extracted directly from noninterpreted, complex 2D NMR spectra using principal component analysis (PCA) to reveal the largest trend(s) across the series. This approach renders peak picking unnecessary for tracking population changes. In 1:1 binding, the first principal component captures the binding isotherm from NMR-detected titrations in fast, slow, and even intermediate and mixed exchange regimes, as illustrated for phospholigand associations with proteins. Although the sigmoidal shifts and line broadening of intermediate exchange distorts binding isotherms constructed conventionally, applying PCA directly to these spectra along with Pareto scaling overcomes the distortion. Applying PCA to time-domain NMR data also yields binding isotherms from titrations in fast or slow exchange. The algorithm readily extracts from magnetic resonance imaging movie time courses such as breathing and heart rate in chest imaging. Similarly, two-step binding processes detected by NMR are easily captured by principal components 1 and 2. PCA obviates the customary focus on specific peaks or regions of images. Applying it directly to a series of complex data will easily delineate binding isotherms, equilibrium shifts, and time courses of reactions or fluctuations.
Fast track in hip arthroplasty
Hansen, Torben Bæk
2017-01-01
‘Fast-track’ surgery was introduced more than 20 years ago and may be defined as a co-ordinated peri-operative approach aimed at reducing surgical stress and facilitating post-operative recovery.The fast-track programmes have now been introduced into total hip arthroplasty (THA) surgery with reduction in post-operative length of stay, shorter convalescence and rapid functional recovery without increased morbidity and mortality. This has been achieved by focusing on a multidisciplinary collaboration and establishing ‘fast-track’ units, with a well-defined organisational set-up tailored to deliver an accelerated peri-operative course of fast-track surgical THA procedures.Fast-track THA surgery now works extremely well in the standard THA patient. However, all patients are different and fine-tuning of the multiple areas in fast-track pathways to get patients with special needs or high co-morbidity burden through a safe and effective fast-track THA pathway is important.In this narrative review, the principles of fast-track THA surgery are presented together with the present status of implementation and perspectives for further improvements. Cite this article: EFORT Open Rev 2017;2. DOI: 10.1302/2058-5241.2.160060. Originally published online at www.efortopenreviews.org PMID:28630756
Zhou, Y; Mendonca, S C; Abel, G A; Hamilton, W; Walter, F M; Johnson, S; Shelton, J; Elliss-Brookes, L; McPhail, S; Lyratzopoulos, G
2018-01-01
In England, 'fast-track' (also known as 'two-week wait') general practitioner referrals for suspected cancer in symptomatic patients are used to shorten diagnostic intervals and are supported by clinical guidelines. However, the use of the fast-track pathway may vary for different patient groups. We examined data from 669 220 patients with 35 cancers diagnosed in 2006-2010 following either fast-track or 'routine' primary-to-secondary care referrals using 'Routes to Diagnosis' data. We estimated the proportion of fast-track referrals by sociodemographic characteristic and cancer site and used logistic regression to estimate respective crude and adjusted odds ratios. We additionally explored whether sociodemographic associations varied by cancer. There were large variations in the odds of fast-track referral by cancer (P<0.001). Patients with testicular and breast cancer were most likely to have been diagnosed after a fast-track referral (adjusted odds ratios 2.73 and 2.35, respectively, using rectal cancer as reference); whereas patients with brain cancer and leukaemias least likely (adjusted odds ratios 0.05 and 0.09, respectively, for brain cancer and acute myeloid leukaemia). There were sex, age and deprivation differences in the odds of fast-track referral (P<0.013) that varied in their size and direction for patients with different cancers (P<0.001). For example, fast-track referrals were least likely in younger women with endometrial cancer and in older men with testicular cancer. Fast-track referrals are less likely for cancers characterised by nonspecific presenting symptoms and patients belonging to low cancer incidence demographic groups. Interventions beyond clinical guidelines for 'alarm' symptoms are needed to improve diagnostic timeliness.
Multiple feature fusion via covariance matrix for visual tracking
NASA Astrophysics Data System (ADS)
Jin, Zefenfen; Hou, Zhiqiang; Yu, Wangsheng; Wang, Xin; Sun, Hui
2018-04-01
Aiming at the problem of complicated dynamic scenes in visual target tracking, a multi-feature fusion tracking algorithm based on covariance matrix is proposed to improve the robustness of the tracking algorithm. In the frame-work of quantum genetic algorithm, this paper uses the region covariance descriptor to fuse the color, edge and texture features. It also uses a fast covariance intersection algorithm to update the model. The low dimension of region covariance descriptor, the fast convergence speed and strong global optimization ability of quantum genetic algorithm, and the fast computation of fast covariance intersection algorithm are used to improve the computational efficiency of fusion, matching, and updating process, so that the algorithm achieves a fast and effective multi-feature fusion tracking. The experiments prove that the proposed algorithm can not only achieve fast and robust tracking but also effectively handle interference of occlusion, rotation, deformation, motion blur and so on.
Fomenko, V; Moreno, B; Million, M; Harrison, J; Akselrod, M
2017-10-25
The neutron-energy dependence of the track-counting sensitivity of fluorescent nuclear track detectors (FNTDs) at two ranges of Mg doping, resulting in different crystal colorations, was investigated. The performance of FNTDs was studied with the following converters: Li-glass for thermal to intermediate-energy neutrons, polyethylene for fast neutrons, and polytetrafluoroethylene (Teflon™) for photon- and radon-background subtraction. The irradiations with monoenergetic neutrons were performed at the National Physics Laboratory (NPL), UK. The energy range was varied from 144 keV to 16.5 MeV in the personal dose equivalent range from 1 to 3 mSv. Monte Carlo simulations were performed to model the response of FNTDs to monoenergetic neutrons. A good agreement with the experimental data was observed suggesting the development of a basic model for future MC studies. Further work will focus on increasing FNTD sensitivity to low-energy neutrons and developing a faster imaging technique for scanning larger areas to improve counting statistics. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
2011-01-01
Background Laparoscopy-assisted surgery, fast-track perioperative treatment are both increasingly used in colorectal cancer treatment, for their short-time benefits of enhanced recovery and short hospital stays. However, the benefits of the integration of the Laparoscopy-assisted surgery, fast-track perioperative treatment, and even with the Xelox chemotherapy, are still unknown. In this study, the three treatments integration is defined as "Fast Track Multi-Discipline Treatment Model" for colorectal cancer and this model extends the benefits to the whole treatment process of colorectal cancer. The main purpose of the study is to explore the feasibility of "Fast Track Multi-Discipline Treatment" model in treatment of colorectal cancer. Methods The trial is a prospective randomized controlled study with 2 × 2 balanced factorial design. Patients eligible for the study will be randomized to 4 groups: (I) Laparoscopic surgery with fast track perioperative treatment and Xelox chemotherapy; (II) Open surgery with fast track perioperative treatment and Xelox chemotherapy; (III) Laparoscopic surgery with conventional perioperative treatment and mFolfox6 chemotherapy; (IV) Open surgery with conventional perioperative treatment and mFolfox6 chemotherapy. The primary endpoint of this study is the hospital stays. The secondary endpoints are the quality of life, chemotherapy related adverse events, surgical complications and hospitalization costs. Totally, 340 patients will be enrolled with 85 patients in each group. Conclusions The study initiates a new treatment model "Fast Track Multi-Discipline Treatment" for colorectal cancer, and will provide feasibility evidence on the new model "Fast Track Multi-Discipline Treatment" for patients with colorectal cancer. Trial registration ClinicalTrials.gov: NCT01080547 PMID:22111914
Zhou, Y; Mendonca, S C; Abel, G A; Hamilton, W; Walter, F M; Johnson, S; Shelton, J; Elliss-Brookes, L; McPhail, S; Lyratzopoulos, G
2018-01-01
Background: In England, ‘fast-track’ (also known as ‘two-week wait’) general practitioner referrals for suspected cancer in symptomatic patients are used to shorten diagnostic intervals and are supported by clinical guidelines. However, the use of the fast-track pathway may vary for different patient groups. Methods: We examined data from 669 220 patients with 35 cancers diagnosed in 2006–2010 following either fast-track or ‘routine’ primary-to-secondary care referrals using ‘Routes to Diagnosis’ data. We estimated the proportion of fast-track referrals by sociodemographic characteristic and cancer site and used logistic regression to estimate respective crude and adjusted odds ratios. We additionally explored whether sociodemographic associations varied by cancer. Results: There were large variations in the odds of fast-track referral by cancer (P<0.001). Patients with testicular and breast cancer were most likely to have been diagnosed after a fast-track referral (adjusted odds ratios 2.73 and 2.35, respectively, using rectal cancer as reference); whereas patients with brain cancer and leukaemias least likely (adjusted odds ratios 0.05 and 0.09, respectively, for brain cancer and acute myeloid leukaemia). There were sex, age and deprivation differences in the odds of fast-track referral (P<0.013) that varied in their size and direction for patients with different cancers (P<0.001). For example, fast-track referrals were least likely in younger women with endometrial cancer and in older men with testicular cancer. Conclusions: Fast-track referrals are less likely for cancers characterised by nonspecific presenting symptoms and patients belonging to low cancer incidence demographic groups. Interventions beyond clinical guidelines for ‘alarm’ symptoms are needed to improve diagnostic timeliness. PMID:29182609
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-04
... (Track I), providing fast examination for applicants desiring it, upon payment of the applicable fee and... examiners or supervisory patent examiners, specialized examiner training for fast track processing...
"Fast Track" and "Traditional Path" Coaches: Affordances, Agency and Social Capital
ERIC Educational Resources Information Center
Rynne, Steven
2014-01-01
A recent development in large-scale coach accreditation (certification) structures has been the "fast tracking" of former elite athletes. Former elite athletes are often exempted from entry-level qualifications and are generally granted access to fast track courses that are shortened versions of the accreditation courses undertaken by…
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2014 CFR
2014-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... merits based upon the pleadings; (3) The Commission may establish a hearing before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires...
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2013 CFR
2013-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... merits based upon the pleadings; (3) The Commission may establish a hearing before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires...
[Fast-track treatment--second revolution of colorectal surgery].
Kellokumpu, Ilmo
2012-01-01
The fast-track treatment model can be regarded as the second revolution of colorectal surgery after the introduction of laparoscopic surgery. In the gastro-surgical unit of the Central Hospital of Central Finland, results equivalent to international studies in colorectal surgery have been achieved by using fast-track model. In a study setting, this treatment model has resulted in significant decrease of total treatment costs and speeded up discharge of the patients from the hospital. The fast-track treatment model requires both a motivated, trained medical team and a motivated patient.
Fast Track Teaching: Beginning the Experiment in Accelerated Leadership Development
ERIC Educational Resources Information Center
Churches, Richard; Hutchinson, Geraldine; Jones, Jeff
2009-01-01
This article provides an overview of the development of the Fast Track teaching programme and personalised nature of the training and support that has been delivered. Fast Track teacher promotion rates are compared to national statistics demonstrating significant progression for certain groups, particularly women. (Contains 3 tables and 3 figures.)
Fast Track: A Language Arts Program for Middle School Gifted
ERIC Educational Resources Information Center
Schneider, Jean
2008-01-01
"Fast Track" is a pseudonym for an accelerated, advanced language arts program for verbally gifted and high potential students in grades 6-8. The critical thinking model used for "Fast Track" was gleaned from Coalition of Essential Schools founder Ted Sizer's Habits of Mind: significance, evidence, connections, perspective, and supposition, as…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-28
... Request; Guidance for Industry: Fast Track Drug Development Programs: Designation, Development, and... information to OMB for review and clearance. Guidance for Industry: Fast Track Drug Development Programs... to industry on fast track policies and procedures outlined in section 506 of the FD&C Act. The...
Aboyans, V; Lacroix, P; Jeannicot, A; Guilloux, J; Bertin, F; Laskar, M
2004-09-01
We assessed the usefulness of fast-track neck sonography with a new-generation hand-held ultrasound scanner in the detection of > or =60% carotid stenosis. Patients with a past history of atherosclerotic disease or presence of risk factors were enrolled. All had fast-track carotid screening with a hand-held ultrasound scanner. Initial assessment was performed with our quick imaging protocol. A second examiner performed a conventional complete carotid duplex as gold-standard. We enrolled 197 consecutive patients with a mean age of 67 years (range 35-94). A carotid stenosis >60% was detected in 13 cases (6%). The sensitivity, specificity, positive and negative predictive value of fast-track sonography was 100%, 64%, 17% and 100%, respectively. Concomitant power Doppler imaging during the fast-track method did not improve accuracy. The use of a fast-track method with a hand-held ultrasound device can reduce the number of unnecessary carotid Duplex and enhance the screening efficiency without missing significant carotid stenoses.
Effect of an emergency department fast track on Press-Ganey patient satisfaction scores.
Hwang, Calvin E; Lipman, Grant S; Kane, Marlena
2015-01-01
Mandated patient surveys have become an integral part of Medicare remuneration, putting hundreds of millions of dollars in funding at risk. The Centers for Medicare & Medicaid Services (CMS) recently announced a patient experience survey for the emergency department (ED). Development of an ED Fast Track, where lower acuity patients are rapidly seen, has been shown to improve many of the metrics that CMS examines. This is the first study examining if ED Fast Track implementation affects Press-Ganey scores of patient satisfaction. We analyzed returned Press-Ganey questionnaires from all ESI 4 and 5 patients seen 11AM - 1PM, August-December 2011 (pre-fast track), and during the identical hours of fast track, August-December 2012. Raw ordinal scores were converted to continuous scores for paired student t-test analysis. We calculated an odds ratio with 100% satisfaction considered a positive response. An academic ED with 52,000 annual visits had 140 pre-fast track and 85 fast track respondents. Implementation of a fast track significantly increased patient satisfaction with the following: wait times (68% satisfaction to 88%, OR 4.13, 95% CI [2.32-7.33]), doctor courtesy (90% to 95%, OR 1.97, 95% CI [1.04-3.73]), nurse courtesy (87% to 95%, OR 2.75, 95% CI [1.46-5.15]), pain control (79% to 87%, OR 2.13, 95% CI [1.16-3.92]), likelihood to recommend (81% to 90%, OR 2.62, 95% CI [1.42-4.83]), staff caring (82% to 91%, OR 2.82, 95% CI [1.54-5.19]), and staying informed about delays (66% to 83%, OR 3.00, 95% CI [1.65-5.44]). Implementation of an ED Fast Track more than doubled the odds of significant improvements in Press-Ganey patient satisfaction metrics and may play an important role in improving ED performance on CMS benchmarks.
Bounded tracking for nonminimum phase nonlinear systems with fast zero dynamics
DOT National Transportation Integrated Search
1996-12-01
A PostScript file. In this paper, tracking control laws for nonminimum phase nonlinear systems with both fast and slow, possibly unstable, zero dynamics are derived. The fast zero dynamics arise from a perturbation of a nominal system. These fast zer...
Real-time tracking of cell cycle progression during CD8+ effector and memory T-cell differentiation.
Kinjyo, Ichiko; Qin, Jim; Tan, Sioh-Yang; Wellard, Cameron J; Mrass, Paulus; Ritchie, William; Doi, Atsushi; Cavanagh, Lois L; Tomura, Michio; Sakaue-Sawano, Asako; Kanagawa, Osami; Miyawaki, Atsushi; Hodgkin, Philip D; Weninger, Wolfgang
2015-02-24
The precise pathways of memory T-cell differentiation are incompletely understood. Here we exploit transgenic mice expressing fluorescent cell cycle indicators to longitudinally track the division dynamics of individual CD8(+) T cells. During influenza virus infection in vivo, naive T cells enter a CD62L(intermediate) state of fast proliferation, which continues for at least nine generations. At the peak of the anti-viral immune response, a subpopulation of these cells markedly reduces their cycling speed and acquires a CD62L(hi) central memory cell phenotype. Construction of T-cell family division trees in vitro reveals two patterns of proliferation dynamics. While cells initially divide rapidly with moderate stochastic variations of cycling times after each generation, a slow-cycling subpopulation displaying a CD62L(hi) memory phenotype appears after eight divisions. Phenotype and cell cycle duration are inherited by the progeny of slow cyclers. We propose that memory precursors cell-intrinsically modulate their proliferative activity to diversify differentiation pathways.
Restoring integrity--A grounded theory of coping with a fast track surgery programme.
Jørgensen, Lene Bastrup; Fridlund, Bengt
2016-01-01
The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. The study design used classical grounded theory. The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients' main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme.
Gao, Peng; Wang, Liping; Zhang, Yu-Yang; Huang, Yuan; Liao, Lei; Sutter, Peter; Liu, Kaihui; Yu, Dapeng; Wang, En-Ge
2016-09-14
In the rechargeable lithium ion batteries, the rate capability and energy efficiency are largely governed by the lithium ion transport dynamics and phase transition pathways in electrodes. Real-time and atomic-scale tracking of fully reversible lithium insertion and extraction processes in electrodes, which would ultimately lead to mechanistic understanding of how the electrodes function and why they fail, is highly desirable but very challenging. Here, we track lithium insertion and extraction in the van der Waals interactions dominated SnS2 by in situ high-resolution TEM method. We find that the lithium insertion occurs via a fast two-phase reaction to form expanded and defective LiSnS2, while the lithium extraction initially involves heterogeneous nucleation of intermediate superstructure Li0.5SnS2 domains with a 1-4 nm size. Density functional theory calculations indicate that the Li0.5SnS2 is kinetically favored and structurally stable. The asymmetric reaction pathways may supply enlightening insights into the mechanistic understanding of the underlying electrochemistry in the layered electrode materials and also suggest possible alternatives to the accepted explanation of the origins of voltage hysteresis in the intercalation electrode materials.
NASA Astrophysics Data System (ADS)
Goudfrooij, Paul
2017-08-01
Recently, deep color-magnitude diagrams from HST data revealed that several massive intermediate-age star clusters in the Magellanic Clouds exhibit extended main-sequence turn-offs (eMSTOs). This discovery posed serious questions regarding the mechanisms responsible for the formation of massive globular clusters and their well-known multiple stellar populations. The nature of eMSTOs is a hotly debated topic of study. Several studies argued that the eMSTOs are caused by an age range of up to a few hundred Myr, while other studies indicate that eMSTOs can instead be caused by a coeval population in which the stars span a range of rotation velocities. Formal evidence to (dis-)prove either scenario still remains at large, in part because stellar tracks that incorporate the effects of rotation have so far only been available for masses > 1.7 Msun whereas the stars in the known eMSTOs of intermediate-age star clusters are less massive. In this proposal we aim to look for photometric signatures of fast rotators in eMSTO clusters that have been observed by HST in three passbands including (at least) F336W and F814W. We will study spreads in different stellar colors, testing against those predicted with the aid of von Zeipel's geometric study for a population of rotating stars with a significant spread in their inclination. Importantly, this spread due to the presence of rotation is predicted to occur along well-defined lines in color-color diagrams, in directions that are distinct from those in color-magnitude diagrams and distinct from the spread predicted for the age range scenario.
Gunnarsdottir, Johanna; Bjornsdottir, Thorbjörg Edda; Halldorsson, Thorhallur Ingi; Halldorsdottir, Gudrun; Geirsson, Reynir Tomas
2011-07-01
To audit whether hospital stay shortened without increasing readmissions after implementation of fast-track methodology for elective cesarean section and characterize what influences length of stay. A fast-track program was initiated in November 2008, with a one year clinical audit and satisfaction survey. Discharge criteria were predefined and midwife home visits included if discharge was within 48 hours. Hospital stay by parity for women with elective section for singleton pregnancy between 1.11. 2008 - 31.10. 2009 (n=213, fast-track 182) was compared to 2003 (n=199) and 2007 (n=183). Readmissions and outpatient visits 2007 and 2008-9 were counted. Reasons for longer stay were recorded in fast-track, and body mass index. Median hospital stay decreased significantly from 81 to 52 hours between 2007 and 2008-9. Readmissions were four in each period and outpatient visit rates similar. In 2008-9, 66% of all women were discharged within 48 hours. Women in the fast-track program were satisfied with early discharge. Hospital stay for parous women was shorter in 2007 compared to 2003, but unchanged for nulliparas. Parity had a minimal influence on length of stay in 2008-9, although nulliparous women ≤ 25 years were more likely to stay >48 hours. Body mass index did not correlate with length of stay. Pain was rarely the reason for a longer stay in the fast-track program and 90% were satisfied with pain-medication after discharge. Most healthy women can be discharged early after singleton birth by elective cesarean, without increasing readmissions.
Pasalich, Dave S.; Witkiewitz, Katie; McMahon, Robert J.; Pinderhughes, Ellen E.
2016-01-01
Little is known about intervening processes that explain how prevention programs improve particular youth antisocial outcomes. We examined whether parental harsh discipline and warmth in childhood differentially account for Fast Track intervention effects on conduct disorder (CD) symptoms and callous-unemotional (CU) traits in early adolescence. Participants included 891 high-risk kindergarteners (69% male; 51% African American) from urban and rural United States communities who were randomized into either the Fast Track intervention (n = 445) or non-intervention control (n = 446) groups. The 10-year intervention included parent management training and other services (e.g., social skills training, universal classroom curriculum) targeting various risk factors for the development of conduct problems. Harsh discipline (Grades 1 through 3) and warmth (Grades 1 and 2) were measured using parent responses to vignettes and direct observations of parent-child interaction, respectively. Parents reported on children’s CD symptoms in Grade 6 and CU traits in Grade 7. Results demonstrated indirect effects of the Fast Track intervention on reducing risk for youth antisocial outcomes. That is, Fast Track was associated with lower scores on harsh discipline, which in turn predicted decreased levels of CD symptoms. In addition, Fast Track was associated with higher scores on warmth, which in turn predicted reduced levels of CU traits. Our findings inform developmental and intervention models of youth antisocial behavior by providing evidence for the differential role of harsh discipline and warmth in accounting for indirect effects of Fast Track on CD symptoms versus CU traits, respectively. PMID:26242993
Restoring integrity—A grounded theory of coping with a fast track surgery programme
Jørgensen, Lene Bastrup; Fridlund, Bengt
2016-01-01
Aims and objectives The aim of this study was to generate a theory conceptualizing and explaining behavioural processes involved in coping in order to identify the predominant coping types and coping type-specific features. Background Patients undergoing fast track procedures do not experience a higher risk of complications, readmission, or mortality. However, such programmes presuppose an increasing degree of patient involvement, placing high educational, physical, and mental demands on the patients. There is a lack of knowledge about how patients understand and cope with fast track programmes. Design The study design used classical grounded theory. Methods The study used a multimodal approach with qualitative and quantitative data sets from 14 patients. Results Four predominant types of coping, with distinct physiological, cognitive, affective, and psychosocial features, existed among patients going through a fast track total hip replacement programme. These patients’ main concern was to restore their physical and psychosocial integrity, which had been compromised by reduced function and mobility in daily life. To restore integrity they economized their mental resources, while striving to fulfil the expectations of the fast track programme. This goal was achieved by being mentally proactive and physically active. Three out of the four predominant types of coping matched the expectations expressed in the fast track programme. The non-matching behaviour was seen among the most nervous patients, who claimed the right to diverge from the programme. Conclusion In theory, four predominant types of coping with distinct physiological, cognitive, affective, and psychosocial features occur among patients going through a fast track total hip arthroplasty programme. PMID:26751199
Pasalich, Dave S; Witkiewitz, Katie; McMahon, Robert J; Pinderhughes, Ellen E
2016-04-01
Little is known about intervening processes that explain how prevention programs improve particular youth antisocial outcomes. We examined whether parental harsh discipline and warmth in childhood differentially account for Fast Track intervention effects on conduct disorder (CD) symptoms and callous-unemotional (CU) traits in early adolescence. Participants included 891 high-risk kindergarteners (69% male; 51% African American) from urban and rural United States communities who were randomized into either the Fast Track intervention (n = 445) or non-intervention control (n = 446) groups. The 10-year intervention included parent management training and other services (e.g., social skills training, universal classroom curriculum) targeting various risk factors for the development of conduct problems. Harsh discipline (Grades 1 to 3) and warmth (Grades 1 and 2) were measured using parent responses to vignettes and direct observations of parent-child interaction, respectively. Parents reported on children's CD symptoms in Grade 6 and CU traits in Grade 7. Results demonstrated indirect effects of the Fast Track intervention on reducing risk for youth antisocial outcomes. That is, Fast Track was associated with lower scores on harsh discipline, which in turn predicted decreased levels of CD symptoms. In addition, Fast Track was associated with higher scores on warmth, which in turn predicted reduced levels of CU traits. Our findings inform developmental and intervention models of youth antisocial behavior by providing evidence for the differential role of harsh discipline and warmth in accounting for indirect effects of Fast Track on CD symptoms versus CU traits, respectively.
Wind, Jan; Hofland, Jan; Preckel, Benedikt; Hollmann, Markus W; Bossuyt, Patrick MM; Gouma, Dirk J; van Berge Henegouwen, Mark I; Fuhring, Jan Willem; Dejong, Cornelis HC; van Dam, Ronald M; Cuesta, Miguel A; Noordhuis, Astrid; de Jong, Dick; van Zalingen, Edith; Engel, Alexander F; Goei, T Hauwy; de Stoppelaar, I Erica; van Tets, Willem F; van Wagensveld, Bart A; Swart, Annemiek; van den Elsen, Maarten JLJ; Gerhards, Michael F; de Wit, Laurens Th; Siepel, Muriel AM; van Geloven, Anna AW; Juttmann, Jan-Willem; Clevers, Wilfred; Bemelman, Willem A
2006-01-01
Background Recent developments in large bowel surgery are the introduction of laparoscopic surgery and the implementation of multimodal fast track recovery programs. Both focus on a faster recovery and shorter hospital stay. The randomized controlled multicenter LAFA-trial (LAparoscopy and/or FAst track multimodal management versus standard care) was conceived to determine whether laparoscopic surgery, fast track perioperative care or a combination of both is to be preferred over open surgery with standard care in patients having segmental colectomy for malignant disease. Methods/design The LAFA-trial is a double blinded, multicenter trial with a 2 × 2 balanced factorial design. Patients eligible for segmental colectomy for malignant colorectal disease i.e. right and left colectomy and anterior resection will be randomized to either open or laparoscopic colectomy, and to either standard care or the fast track program. This factorial design produces four treatment groups; open colectomy with standard care (a), open colectomy with fast track program (b), laparoscopic colectomy with standard care (c), and laparoscopic surgery with fast track program (d). Primary outcome parameter is postoperative hospital length of stay including readmission within 30 days. Secondary outcome parameters are quality of life two and four weeks after surgery, overall hospital costs, morbidity, patient satisfaction and readmission rate. Based on a mean postoperative hospital stay of 9 +/- 2.5 days a group size of 400 patients (100 each arm) can reliably detect a minimum difference of 1 day between the four arms (alfa = 0.95, beta = 0.8). With 100 patients in each arm a difference of 10% in subscales of the Short Form 36 (SF-36) questionnaire and social functioning can be detected. Discussion The LAFA-trial is a randomized controlled multicenter trial that will provide evidence on the merits of fast track perioperative care and laparoscopic colorectal surgery in patients having segmental colectomy for malignant disease. PMID:17134506
Fast-Track Management of Patients Undergoing Proximal Pancreatic Resection
French, JJ; Mansfield, SD; Jaques, K; Jaques, BC; Manas, DM; Charnley, RM
2009-01-01
INTRODUCTION To avoid the risk of complications of biliary drainage, a feasibility study was carried out to determine whether it might be possible to fast-track surgical treatment, with resection before biliary drainage, in jaundiced patients with proximal pancreatic/peri-ampullary malignancy. PATIENTS AND METHODS Over an 18-month period, based on their presenting bilirubin levels and other logistical factors, all jaundiced patients who might be suitable for fast-track management were identified. Data on complications and hospital stay were compared with those patients in whom a conventional pathway (with biliary drainage) was used during the same time period. Data were also compared with a group of patients from the preceding 6 months. RESULTS Nine patients were fast-tracked and 49 patients treated in the conventional pathway. Fast-track patients mean (SD) serum bilirubin level was 265 μmol/l (81.6) at the time of the operation compared to 43 μmol/l (51.3; P ≥ 0.0001) in conventional patients. Mean (SD) of time from referral to operation, 14 days (9) versus 59 days (36.9), was significantly shorter in fast-track patients than conventional patients (P ≤ 0.0001). Length of hospital stay mean (SD) at 17 (6) days versus 22 days (19.6; P = 0.2114), surgical complications and mortality in fast-track patients were similar to conventional patients. Prior to surgery, the 49 conventional patients underwent a total of 73 biliary drainage procedures resulting in seven major complications. Comparison with the group of patients from the previous 6 months indicated that the conventional group were not disadvantaged. CONCLUSIONS Fast-track management by resection without biliary drainage of selected patients with distal biliary strictures is safe and has the potential to reduce the waiting time to surgery, overall numbers of biliary drainage procedures and the complications thereof. PMID:19220943
Beogo, Idrissa; Liu, Chieh-Yu; Dlamini, Colile P; Gagnon, Marie-Pierre
2015-01-01
Nursing education has evolved over time to fit societies' increasing care needs. Innovations in nursing education draw thorny debates on potential jeopardy in the quality, safety, and efficacy of nurse graduates. Accelerated nursing education programs have been among landmark strategic changes to address the persistent bedside nurse shortage. Despite the dearth of empirical studies in sub-Saharan Africa (SSA), the National School of Public Health of Burkina Faso has developed a State Diploma Nursing (SDN) fast-track program. With innovative features, the program is nested into the traditional SDN program. This study investigates preliminary outcomes of the implemented policy using the initial cohort that went through the program. Comparison of the traditional generic program and the fast-track one is drawn to inform nursing education policy. The study was conducted in the three campuses delivering the SDN program. Data collected from a representative sample included 255 students from the 2006-2009 cohort, after concluding the program. Surveyed students were assessed according to the program entry status. Outcomes were measured using students' academic performance. Besides descriptive analysis, bivariate t-test, F-test, and multivariate ordinary least square regression (OLSR) were employed to determine the comparative pattern between the traditional generic and the newly nested fast-track program. Students' varied statuses (private pre-registration, state pre-registration, private post-registration, and state post-registration) were kept to better outline the findings trend. A fifth (19.6 %) of surveyed students were enrolled in the fast-track stream from which, one third (33.7 %) consisted of post-registered students. Fast-track students comparatively achieved the best academic performance (mean: 73.68/100, SD: 5.52). Multivariate OLSR confirmed that fast-track students performed better (β: 5.559, p < 0.001), and further informed differences between campuses. Students entry status also displayed significant differences, yet the academic performance of post-registered students from traditional generic versus fast-track was similar (p = 0.409). Findings suggest that fast-track program students performed better than the ones from the traditional generic program. The uniqueness and success of this mixed nursing program experience sheds light for nursing educators engaged in policy making. The study results can serve as a crucial foundation for policymakers to alleviate the nurse shortage in SSA.
42 CFR 417.840 - Administrative review procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... fast-track appeals that affect its Medicare enrollees; and (b) Reconsiderations, hearings, Medicare Appeals Council review, and judicial review of the organization determinations and fast-track appeals...
42 CFR 417.840 - Administrative review procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... fast-track appeals that affect its Medicare enrollees; and (b) Reconsiderations, hearings, Medicare Appeals Council review, and judicial review of the organization determinations and fast-track appeals...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
Xu, Dong; Li, Jun; Song, Yongmao; Zhou, Jiaojiao; Sun, Fangfang; Wang, Jianwei; Duan, Yin; Hu, Yeting; Liu, Yue; Wang, Xiaochen; Sun, Lifeng; Wu, Linshan; Ding, Kefeng
2015-02-04
Many clinical trials had repeatedly shown that fast-track perioperative care and laparoscopic surgery are both preferred in the treatment of colorectal cancer. But few studies were designed to explore the diverse biochemical impacts of the two counterparts on human immunologic and nutritional status. Ninety-two cases of colorectal cancer patients meeting the inclusion criteria were randomized to four groups: laparoscopy with fast-track treatment (LAFT); open surgery with fast-track treatment (OSFT); laparoscopy with conventional treatment (LAC); open surgery with conventional treatment (OSC). Peripheral blood tests including nutritional factors (albumin, prealbumin, and transferrin), humoral immunologic factors (IgG, IgM, and IgA), and cellular immunologic factors (T and NK cells) were evaluated. Blood samples were collected preoperatively (baseline) and 12 and 96 h after surgery (indicated as POH12 and POH96, respectively). Albumin, transferrin, prealbumin, and IgG levels were the highest in the LAFT group for both POH12 and POH96 time intervals. Repeated measures (two-way ANOVA) indicated that the difference of albumin, transferrin, and IgG level were attributed to surgery type (P < 0.05) and not perioperative treatment (P > 0.05). Only in the laparoscopy-included groups, the relative albumin and IgG levels of POH96 were obviously higher than that of POH12. Laparoscopic surgery accelerated postoperative nutrition and immune levels rising again while fast-track treatment retarded the drop of postoperative nutrition and immune levels. Laparoscopic surgery might play a more important role than fast-track treatment in the earlier postoperative recovery of nutritional and immunologic status. Combined laparoscopic surgery with fast-track treatment provided best postoperative recovery of nutrition and immune status. These results should be further compared with the clinical outcomes of our FTMDT trial (clinicaltrials.gov: NCT01080547).
Patient experience in fast-track hip and knee arthroplasty--a qualitative study.
Specht, Kirsten; Kjaersgaard-Andersen, Per; Pedersen, Birthe D
2016-03-01
To explore the lived experience of patients in fast-track primary unilateral total hip and knee arthroplasty from the first visit at the outpatient clinic until discharge. Fast-track has resulted in increased effectiveness, including faster recovery and shorter length of stay to about two days after hip and knee arthroplasty. However, the patient perspective in fast-track with a median length of stay of less than three days has been less investigated. A qualitative design. A phenomenological-hermeneutic approach was used, inspired by Paul Ricoeur's theory of narrative and interpretation. Eight patients were included. Semi-structured interviews and participant observation were performed. Three themes emerged: dealing with pain; feelings of confidence or uncertainty - the meaning of information; and readiness for discharge. Generally, the patients were resistant to taking analgesics and found it difficult to find out when to take supplementary analgesics; therefore, nursing staff needed enough expertise to take responsibility. Factors that increased patients' confidence: information about fast-track, meeting staff before admission and involving relatives. In contrast, incorrect or conflicting information and a lack of respect for privacy led to uncertainty. In preparing for early discharge, sufficient pain management, feeling well-rested and optimal use of time during hospitalisation were important. The study shows the importance of dealing with pain and getting the right information and support to have confidence in the fast-track programme, to be ready for discharge and to manage postoperatively at home. In fast-track focusing on early discharge, there is an increased need for evidence-based nursing practice, including a qualified judgement of what is best for the patient in certain situations. The knowledge should be gleaned from: research; the patients' expertise, understanding and situation; and nurses' knowledge, skills and experience. © 2015 John Wiley & Sons Ltd.
DOT National Transportation Integrated Search
1978-07-01
This brochure describes the 22 test sections of the Federal Railroad Administration's FAST Track and the various track and mechanical measurements being made as of September 1977 - the end of the first year of operation at the facility. Because of th...
42 CFR 417.840 - Administrative review procedures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... determinations and fast-track appeals that affect its Medicare enrollees; and (b) Reconsiderations, hearings, Medicare Appeals Council review, and judicial review of the organization determinations and fast-track...
42 CFR 417.840 - Administrative review procedures.
Code of Federal Regulations, 2013 CFR
2013-10-01
... determinations and fast-track appeals that affect its Medicare enrollees; and (b) Reconsiderations, hearings, Medicare Appeals Council review, and judicial review of the organization determinations and fast-track...
42 CFR 417.840 - Administrative review procedures.
Code of Federal Regulations, 2014 CFR
2014-10-01
... determinations and fast-track appeals that affect its Medicare enrollees; and (b) Reconsiderations, hearings, Medicare Appeals Council review, and judicial review of the organization determinations and fast-track...
Patients' satisfaction with fast-track surgery in gynaecological oncology.
Philp, S; Carter, J; Pather, S; Barnett, C; D'Abrew, N; White, K
2015-07-01
This study investigates the experience and satisfaction with care of fast-tracked gynaecological patients. The Sydney Gynaecological Oncology Group, New South Wales, Australia, has previously shown the benefits of a fast-track surgery programme for gynaecology patients with both complex benign gynaecological pathology and gynaecological malignancy. The question of whether these benefits translate into a positive experience for fast-tracked patients, in the context of their hospital stay and healthcare team care, has not been previously explored in detail. A self-administered satisfaction questionnaire incorporating the European Organisation for Research and Treatment of Cancer (EORTC) cancer in-patient satisfaction with care measure (INPATSAT-32) questionnaire with additional questions was administered to 106 gynaecology participants at Royal Prince Alfred Hospital. Participants reported high levels of satisfaction with patient care and support received from doctors, ward nurses and the hospital as a service and care organisation, within the context of a fast-track surgical programme. Early hospital discharge after gynaecological surgery results in both enhanced recovery after surgery (ERAS) and high levels of patient satisfaction. © 2014 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Warmer, F.; Beidler, C. D.; Dinklage, A.; Wolf, R.; The W7-X Team
2016-07-01
As a starting point for a more in-depth discussion of a research strategy leading from Wendelstein 7-X to a HELIAS power plant, the respective steps in physics and engineering are considered from different vantage points. The first approach discusses the direct extrapolation of selected physics and engineering parameters. This is followed by an examination of advancing the understanding of stellarator optimisation. Finally, combining a dimensionless parameter approach with an empirical energy confinement time scaling, the necessary development steps are highlighted. From this analysis it is concluded that an intermediate-step burning-plasma stellarator is the most prudent approach to bridge the gap between W7-X and a HELIAS power plant. Using a systems code approach in combination with transport simulations, a range of possible conceptual designs is analysed. This range is exemplified by two bounding cases, a fast-track, cost-efficient device with low magnetic field and without a blanket and a device similar to a demonstration power plant with blanket and net electricity power production.
A Fast MEANSHIFT Algorithm-Based Target Tracking System
Sun, Jian
2012-01-01
Tracking moving targets in complex scenes using an active video camera is a challenging task. Tracking accuracy and efficiency are two key yet generally incompatible aspects of a Target Tracking System (TTS). A compromise scheme will be studied in this paper. A fast mean-shift-based Target Tracking scheme is designed and realized, which is robust to partial occlusion and changes in object appearance. The physical simulation shows that the image signal processing speed is >50 frame/s. PMID:22969397
[Principles of fast track surgery. Multimodal perioperative therapy programme].
Kehlet, H
2009-08-01
Recent evidence has documented that a combination of single-modality evidence-based care principles into a multimodal effort to enhance postoperative recovery (the fast track methodology) has led to enhanced recovery with reduced medical morbidity, need for hospitalisation and convalescence. Nevertheless, general implementation of fast track surgery has been relatively slow despite concomitant economic benefits. Further improvement in postoperative outcome may be obtained by developments within each care principle with a specific focus on minimally invasive surgery, effective multimodal, non-opioid analgesia and pharmacological stress reduction.
78 FR 33836 - CPSC Safety Academy
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-05
... compliance issues, and the fast track recall program. The Safety Academy is structured such that the morning... continued, including Fast Track and Section 15; and (Panel 3) Flammable Fabrics, Drawstrings, and Sleepwear...
King, Adam C; Newell, Karl M
2015-10-01
The experiment investigated the effect of selectively augmenting faster time scales of visual feedback information on the learning and transfer of continuous isometric force tracking tasks to test the generality of the self-organization of 1/f properties of force output. Three experimental groups tracked an irregular target pattern either under a standard fixed gain condition or with selectively enhancement in the visual feedback display of intermediate (4-8 Hz) or high (8-12 Hz) frequency components of the force output. All groups reduced tracking error over practice, with the error lowest in the intermediate scaling condition followed by the high scaling and fixed gain conditions, respectively. Selective visual scaling induced persistent changes across the frequency spectrum, with the strongest effect in the intermediate scaling condition and positive transfer to novel feedback displays. The findings reveal an interdependence of the timescales in the learning and transfer of isometric force output frequency structures consistent with 1/f process models of the time scales of motor output variability.
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2012 CFR
2012-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2010 CFR
2010-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2013 CFR
2013-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2014 CFR
2014-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2011 CFR
2011-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
77 FR 48506 - CPSC Safety Academy
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-14
... issues and the Fast-Track process. These discussions will be held in a panel format, with a brief... Nuances of 6b''; or ``Fast-Track Process--Compliance.'' An official of the General Administration of...
NASA Astrophysics Data System (ADS)
Mohrfeld-Halterman, J. A.; Uddin, M.
2016-07-01
We described in this paper the development of a high fidelity vehicle aerodynamic model to fit wind tunnel test data over a wide range of vehicle orientations. We also present a comparison between the effects of this proposed model and a conventional quasi steady-state aerodynamic model on race vehicle simulation results. This is done by implementing both of these models independently in multi-body quasi steady-state simulations to determine the effects of the high fidelity aerodynamic model on race vehicle performance metrics. The quasi steady state vehicle simulation is developed with a multi-body NASCAR Truck vehicle model, and simulations are conducted for three different types of NASCAR race tracks, a short track, a one and a half mile intermediate track, and a higher speed, two mile intermediate race track. For each track simulation, the effects of the aerodynamic model on handling, maximum corner speed, and drive force metrics are analysed. The accuracy of the high-fidelity model is shown to reduce the aerodynamic model error relative to the conventional aerodynamic model, and the increased accuracy of the high fidelity aerodynamic model is found to have realisable effects on the performance metric predictions on the intermediate tracks resulting from the quasi steady-state simulation.
Biomimetic model systems of rigid hair beds: Part II - Experiment
NASA Astrophysics Data System (ADS)
Jammalamadaka, Mani S. S.; Hood, Kaitlyn; Hosoi, Anette
2017-11-01
Crustaceans - such as lobsters, crabs and stomapods - have hairy appendages that they use to recognize and track odorants in the surrounding fluid. An array of rigid hairs impedes flow at different rates depending on the spacing between hairs and the Reynolds number, Re. At larger Reynolds number (Re>1), fluid travels through the hairs rather than around them, a phenomenon called leakiness. Crustaceans flick their appendages at different speeds in order to manipulate the leakiness between the hairs, allowing the hairs to either detect the odors in a sample of fluid or collect a new sample. Theoretical and numerical studies predict that there is a fast flow region near the hairs that moves closer to the hairs as Re increases. Here, we test this theory experimentally. We 3D printed rigid hairs with an aspect ratio of 30:1 in rectangular arrays with different hair packing fractions. We custom built an experimental setup which establishes poiseuille flow at intermediate Re, Re <=200. We track the flow dynamics through the hair beds using tracer particles and Particle Imaging Velocimetry. We will then compare the modelling predictions with the experimental outcomes.
Zoremba, Martin; Kratz, Thomas; Dette, Frank; Wulf, Hinnerk; Steinfeldt, Thorsten; Wiesmann, Thomas
2015-01-01
After shoulder surgery performed in patients with interscalene nerve block (without general anesthesia), fast track capability and postoperative pain management in the PACU are improved compared with general anesthesia alone. However, it is not known if these evidence-based benefits still exist when the interscalene block is combined with general anesthesia. We retrospectively analyzed a prospective cohort data set of 159 patients undergoing shoulder arthroscopy with general anesthesia alone (n = 60) or combined with an interscalene nerve block catheter (n = 99) for fast track capability time. Moreover, comparisons were made for VAS scores, analgesic consumption in the PACU, pain management, and lung function measurements. The groups did not differ in mean time to fast track capability (22 versus 22 min). Opioid consumption in PACU was significantly less in the interscalene group, who had significantly better VAS scores during PACU stay. Patients receiving interscalene blockade had a significantly impaired lung function postoperatively, although this did not affect postoperative recovery and had no impact on PACU times. The addition of interscalene block to general anesthesia for shoulder arthroscopy did not enhance fast track capability. Pain management and VAS scores were improved in the interscalene nerve block group.
Low-Frequency Waves in Cold Three-Component Plasmas
NASA Astrophysics Data System (ADS)
Fu, Qiang; Tang, Ying; Zhao, Jinsong; Lu, Jianyong
2016-09-01
The dispersion relation and electromagnetic polarization of the plasma waves are comprehensively studied in cold electron, proton, and heavy charged particle plasmas. Three modes are classified as the fast, intermediate, and slow mode waves according to different phase velocities. When plasmas contain positively-charged particles, the fast and intermediate modes can interact at the small propagating angles, whereas the two modes are separate at the large propagating angles. The near-parallel intermediate and slow waves experience the linear polarization, circular polarization, and linear polarization again, with the increasing wave number. The wave number regime corresponding to the above circular polarization shrinks as the propagating angle increases. Moreover, the fast and intermediate modes cause the reverse change of the electromagnetic polarization at the special wave number. While the heavy particles carry the negative charges, the dispersion relations of the fast and intermediate modes are always separate, being independent of the propagating angles. Furthermore, this study gives new expressions of the three resonance frequencies corresponding to the highly-oblique propagation waves in the general three-component plasmas, and shows the dependence of the resonance frequencies on the propagating angle, the concentration of the heavy particle, and the mass ratio among different kinds of particles. supported by National Natural Science Foundation of China (Nos. 11303099, 41531071 and 41574158), and the Youth Innovation Promotion Association CAS
Design of a Holonic Control Architecture for Distributed Sensor Management
2009-09-01
Tracking tasks require only intermit - tent access to the sensors to maintain a given track quality. The higher the specified quality, the more often...resolution of the sensor (i.e., sensor mode), which can be adjusted to compensate for fast moving targets tracked over long ranges, or slower moving...but provides higher data update rates that are beneficial when tracking fast agile targets (i.e., a fighter). Table A.2 illustrates the dependence of
FAST TRACK COMMUNICATION: Variation of equation of state parameters in the Mg2(Si1 - xSnx) alloys
NASA Astrophysics Data System (ADS)
Pulikkotil, J. J.; Alshareef, H. N.; Schwingenschlögl, U.
2010-09-01
Thermoelectric performance peaks up for intermediate Mg2(Si1 - xSnx) alloys, but not for isomorphic and isoelectronic Mg2(Si1 - xGex) alloys. A comparative study of the equation of state parameters is performed using density functional theory, Green's function technique, and the coherent potential approximation. Anomalous variation of the bulk modulus is found in Mg2(Si1 - xSnx) but not in the Mg2(Si1 - xGex) analogs. Assuming a Debye model, linear variations of the unit cell volume and pressure derivative of the bulk modulus suggest that lattice effects are important for the thermoelectric response. From the electronic structure perspective, Mg2(Si1 - xSnx) is distinguished by a strong renormalization of the anion-anion hybridization.
Tsilimparis, N; Haase, O; Wendling, P; Kipfmüller, K; Schmid, M; Engemann, R; Schwenk, W
2010-09-01
The natural course of sigmoid colon diverticulitis during conservative therapy and the assessment of the perioperative morbidity after sigmoid colon resection are differently evaluated by surgeons and gastroenterologists. The "fast-track" rehabilitation accelerates the reconvalescence and reduces the rate of postoperative general complications after colorectal surgery. The results of the laparoscopic "Fast-track" sigmoidectomy should be examined within a quality assurance program to better evaluate the perioperative risks following surgical management of diverticulitis. A prospective data collection within the voluntary quality assurance program "fast-track" Kolon II was performed. All participating clinics agreed on a multimodal, evidence-based standard perioperative treatment in terms of a "fast-track" rehabilitation for elective operations for sigmoid diverticulitis. Data from 846 patients undergoing laparoscopic "fast-track" sigmoid colon resection in 23 surgical departments in Germany were collected and evaluated. The mean age of the patients was 63 years (range 23 - 91). 203 patients (24 %) had severe co-morbidities (ASA classification III - IV). A conversion to conventional open surgery was necessary in 51 cases (6 %). Complications occurred in 93 patients (11 %). 76 patients suffered a surgical complication (8.9 %) and 32 patients (3.8 %) a general complication. Two patients died postoperatively due to multi-organ failure following anastomotic leaks. The patients took solid food in median on day 1 after surgery (range, 0 - 5) and passed stool on day 2 (range, 0 - 22). Predefined discharge criteria (free of pain on oral medication, normal oral feeding, stool) were met on day 4 (range, 1 - 58) and the patients were discharged on day 7 (range, 3 - 72). The 30-day re-admission rate was 3.9 %. Patients undergoing laparoscopic "fast-track" sigmoidectomy had a low rate of general complications and had a rapid reconvalescence with a short postoperative in-patient treatment as documented in a german quality assurance program. Copyright Georg Thieme Verlag KG Stuttgart . New York.
Demonstration of a Single-Crystal Reflector-Filter for Enhancing Slow Neutron Beams
Muhrer, Guenter; Schönfeldt, Troels; Iverson, Erik B.; ...
2016-06-14
The cold polycrystalline beryllium reflector-filter concept has been used to enhance the cold neutron emission of cryogenic hydrogen moderators, while suppressing the intermediate wavelength and fast neutron emission at the same time. While suppressing the fast neutron emission is often desired, the suppression of intermediate wavelength neutrons is often unwelcome. It has been hypothesized that replacing the polycrystalline reflector-filter concept with a single-crystal reflector-filter concept would overcome the suppression of intermediate wavelength neutrons and thereby extend the usability of the reflector-filter concept to shorter but still important wavelengths. In this paper we present the first experimental data on a single-crystalmore » reflector-filter and compare experimental results with hypothesized performance. We find that a single-crystal reflector-filter retains the long-wavelength benefit of the polycrystalline reflector-filter, without suffering the same loss of important intermediate wavelength neutrons. Ultimately, this finding extends the applicability of the reflector-filter concept to intermediate wavelengths, and furthermore indicates that the reflector-filter benefits arise from its interaction with fast (background) neutrons, not with intermediate wavelength neutrons of potential interest in many types of neutron scattering.« less
Fast-track surgery: Toward comprehensive peri-operative care
Nanavati, Aditya J.; Prabhakar, S.
2014-01-01
Fast-track surgery is a multimodal approach to patient care using a combination of several evidence-based peri-operative interventions to expedite recovery after surgery. It is an extension of the critical pathway that integrates modalities in surgery, anesthesia, and nutrition, enforces early mobilization and feeding, and emphasizes reduction of the surgical stress response. It entails a great partnership between a surgeon and an anesthesiologist with several other specialists to form a multi-disciplinary team, which may then engage in patient care. The practice of fast-track surgery has yielded excellent results and there has been a significant reduction in hospital stay without a rise in complications or re-admissions. The effective implementation begins with the formulation of a protocol, carrying out each intervention and gathering outcome data. The care of a patient is divided into three phases: Before, during, and after surgery. Each stage needs active participation of few or all the members of the multi-disciplinary team. Other than surgical technique, anesthetic drugs, and techniques form the cornerstone in the ability of the surgeon to carry out a fast-track surgery safely. It is also the role of this team to keep abreast with the latest development in fast-track methodology and make appropriate changes to policy. In the Indian healthcare system, there is a huge benefit that may be achieved by the successful implementation of a fast-track surgery program at an institutional level. The lack of awareness regarding this concept, fear and apprehension regarding its implementation are the main barriers that need to be overcome. PMID:25886214
The yield of colorectal cancer among fast track patients with normocytic and microcytic anaemia.
Panagiotopoulou, I G; Fitzrol, D; Parker, R A; Kuzhively, J; Luscombe, N; Wells, A D; Menon, M; Bajwa, F M; Watson, M A
2014-05-01
We receive fast track referrals on the basis of iron deficiency anaemia (IDA) for patients with normocytic anaemia or for patients with no iron studies. This study examined the yield of colorectal cancer (CRC) among fast track patients to ascertain whether awaiting confirmation of IDA is necessary prior to performing bowel investigations. A review was undertaken of 321 and 930 consecutive fast track referrals from Centre A and Centre B respectively. Contingency tables were analysed using Fisher's exact test. Logistic regression analyses were performed to investigate significant predictors of CRC. Overall, 229 patients were included from Centre A and 689 from Centre B. The odds ratio for microcytic anaemia versus normocytic anaemia in the outcome of CRC was 1.3 (95% confidence interval [CI]: 0.5-3.9) for Centre A and 1.6 (95% CI: 0.8-3.3) for Centre B. In a logistic regression analysis (Centre B only), no significant difference in CRC rates was seen between microcytic and normocytic anaemia (adjusted odds ratio: 1.9, 95% CI: 0.9-3.9). There was no statistically significant difference in the yield of CRC between microcytic and normocytic anaemia (p=0.515, Fisher's exact test) in patients with anaemia only and no colorectal symptoms. Finally, CRC cases were seen in both microcytic and normocytic groups with or without low ferritin. There is no significant difference in the yield of CRC between fast track patients with microcytic and normocytic anaemia. This study provides insufficient evidence to support awaiting confirmation of IDA in fast track patients with normocytic anaemia prior to requesting bowel investigations.
Fast-track surgery: Toward comprehensive peri-operative care.
Nanavati, Aditya J; Prabhakar, S
2014-01-01
Fast-track surgery is a multimodal approach to patient care using a combination of several evidence-based peri-operative interventions to expedite recovery after surgery. It is an extension of the critical pathway that integrates modalities in surgery, anesthesia, and nutrition, enforces early mobilization and feeding, and emphasizes reduction of the surgical stress response. It entails a great partnership between a surgeon and an anesthesiologist with several other specialists to form a multi-disciplinary team, which may then engage in patient care. The practice of fast-track surgery has yielded excellent results and there has been a significant reduction in hospital stay without a rise in complications or re-admissions. The effective implementation begins with the formulation of a protocol, carrying out each intervention and gathering outcome data. The care of a patient is divided into three phases: Before, during, and after surgery. Each stage needs active participation of few or all the members of the multi-disciplinary team. Other than surgical technique, anesthetic drugs, and techniques form the cornerstone in the ability of the surgeon to carry out a fast-track surgery safely. It is also the role of this team to keep abreast with the latest development in fast-track methodology and make appropriate changes to policy. In the Indian healthcare system, there is a huge benefit that may be achieved by the successful implementation of a fast-track surgery program at an institutional level. The lack of awareness regarding this concept, fear and apprehension regarding its implementation are the main barriers that need to be overcome.
78 FR 52166 - Quantitative Messaging Research
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-22
... COMMODITY FUTURES TRADING COMMISSION Quantitative Messaging Research AGENCY: Commodity Futures... survey will follow qualitative message testing research (for which CFTC received fast-track OMB approval... message testing research (for which CFTC received fast-track OMB approval) and is necessary to identify...
42 CFR 422.624 - Notifying enrollees of termination of provider services.
Code of Federal Regulations, 2012 CFR
2012-10-01
... begins. (iii) A description of the enrollee's right to a fast-track appeal under § 422.626, including... procedures if the enrollee fails to meet the deadline for a fast-track IRE appeal. (iv) The enrollee's right...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-23
.... 1660-NEW; FEMA Form 089-4, TSGP Investment Justification; FEMA Form 089-27, Fast Track Cost Training...-27, Fast Track Cost Training Matrix. Abstract: The TSGP is an important component of the Department...
42 CFR 422.624 - Notifying enrollees of termination of provider services.
Code of Federal Regulations, 2013 CFR
2013-10-01
... begins. (iii) A description of the enrollee's right to a fast-track appeal under § 422.626, including... procedures if the enrollee fails to meet the deadline for a fast-track IRE appeal. (iv) The enrollee's right...
42 CFR 422.624 - Notifying enrollees of termination of provider services.
Code of Federal Regulations, 2011 CFR
2011-10-01
... begins. (iii) A description of the enrollee's right to a fast-track appeal under § 422.626, including... procedures if the enrollee fails to meet the deadline for a fast-track IRE appeal. (iv) The enrollee's right...
42 CFR 422.624 - Notifying enrollees of termination of provider services.
Code of Federal Regulations, 2010 CFR
2010-10-01
... begins. (iii) A description of the enrollee's right to a fast-track appeal under § 422.626, including... procedures if the enrollee fails to meet the deadline for a fast-track IRE appeal. (iv) The enrollee's right...
42 CFR 422.624 - Notifying enrollees of termination of provider services.
Code of Federal Regulations, 2014 CFR
2014-10-01
... begins. (iii) A description of the enrollee's right to a fast-track appeal under § 422.626, including... procedures if the enrollee fails to meet the deadline for a fast-track IRE appeal. (iv) The enrollee's right...
Fast-Track Teacher Recruitment.
ERIC Educational Resources Information Center
Grant, Franklin Dean
2001-01-01
Schools need a Renaissance human-resources director to implement strategic staffing and fast-track teacher-recruitment plans. The HR director must attend to customer satisfaction, candidate supply, web-based recruitment possibilities, stabilization of newly hired staff, retention of veteran staff, utilization of retired employees, and latest…
Fast-Track Cleanup at Closing DoD Installations
The Fast-Track Cleanup program strives to make parcels available for reuse as quickly as possible by the transfer of uncontaminated or remediated parcels, the lease of contaminated parcels where cleanup is underway, or the 'early transfer' of contaminated property undergoing cleanup.
Castorina, Sergio; Guglielmino, Claudia; Castrogiovanni, Paola; Szychlinska, Marta Anna; Ioppolo, Francesco; Massimino, Paolo; Leonardi, Pietro; Maci, Christian; Iannuzzi, Maurizio; Di Giunta, Angelo; Musumeci, Giuseppe
2017-01-01
Summary Background During the last years, programs to enhance postoperative recovery and decrease morbidity after total knee arthroplasty, have been developed across a variety of surgical procedures and referred to as “Fast-Track Surgery”. In this study we aimed to find some answers in the management of osteoarthritic patients subjected to total knee arthroplasty, by using the Fast-Track methodology. To this purpose we evaluated parameters such as early mobilization of patients, better pain management, bleeding, possible complications, reduced hospitalization time, an overall improved recovery and patient satisfaction. Methods 132 patients were selected, of which, 95 treated with “Fast Track” method and 37 treated with traditional method (control group). All the patients were hospitalized and underwent the same rehabilitation program for the first three days after surgery. Results In both groups, the parameters of pain and deformity demonstrated the most rapid improvement, while those of function and movement were normalized as gradual and progressive improvement over the next 2 months. The different functional test used (Barthel, MRC, VAS) showed that the mean values were significantly greater in Fast Track group when compared to the control. Conclusion The results of the study confirm that the application of the Fast Track protocol in orthopaedics after total knee replacement results in rapid post-surgery recovery. Level of evidence IV. Case series, low-quality cohort or case-control studies. PMID:29387645
van Harten, W H; Goedbloed, N; Boekhout, A H; Heintzbergen, S
2018-02-07
In general, patients with a cancer suspicion visit the hospital multiple times before diagnosis is completed. Using various "operations management" techniques a few fast track diagnostic services were implemented in the Netherlands Cancer Institute (NKI) in 2006. Growing patient numbers and increasing process complexity, led to diminished service levels. To decrease the amount of patient visits and to extend these services beyond the (obvious) breast cancer services, fast track diagnostics is now implemented for all 18 cancer types that present with a frequency of minimally one per week. The throughput time (first visit to diagnosis conversation) was measured before, and after implementation of fast track diagnostics. The process was redesigned closely involving the multidisciplinary teams. In an eclectic approach elements from lean management, theory of constraints and mathematical analysis were used to organize slots per tumor type for MRI, CT, PET and echography. A post measurement was performed after 3 and 6 months. In pre measurement access time was calculated to be 10 to 15 workdays, mean throughput time was 6.0 workdays. It proved possible to design the process of 18 tumors as a fast track, of which 7 as "one stop shop" (diagnosis completed in one visit). Involvement of clinical- and board leadership, massive communication efforts and commitment of physicians to reschedule their work proved decisive. After 3 and 6 months of implementation, the mean access time was 8.2 and 8.7 workdays respectively and mean throughput time was 3.4 and 3.3 workdays respectively. Throughput- and access time were considerably shortened after implementation of fast track diagnostics for 18 cancer types. The involvement of physicians in reorganizing their work and rapid responding to their needs during the implementation phase were a crucial success factor.
Fast Track Extubation In Adult Patients On Pump Open Heart Surgery At A Tertiary Care Hospital.
Akhtar, Mohammad Irfan; Sharif, Hasanat; Hamid, Mohammad; Samad, Khalid; Khan, Fazal Hameed
2016-01-01
Fast-track cardiac surgery programs have been established as the standard of cardiac surgical care. Studies have shown that early extubation in elective cardiac surgery patients, including coronary and non-coronary open-heart surgery patients does not increase perioperative morbidity and mortality. The objective of this observational study was to determine the success and failure profile of fast track extubation (FTE) practice in adult open-heart surgical patients. The study was conducted at cardiac operating room and Cardiac Intensive Care Unit (CICU) of a tertiary care hospital for a period of nine months, i.e., from Oct 2014 to June-2015. All on pump elective adult cardiac surgery patients including isolated CABG, isolated Valve replacements, combined procedures and aortic root replacements were enrolled in the study. Standardized anesthetic technique was adopted. Surgical and bypass techniques were tailored according to the procedure. Success of Fast track extubation was defined as extubation within 6 hours of arrival in CICU. A total of 290 patients were recruited. The average age of the patients was 56.3±10.5 years. There were 77.6% male and 22.4% female patients. Overall success rate was 51.9% and failure rate was 48.1%. The peri-operative renal insufficiency, cross clamp time and CICU stay (hours) were significantly lower in success group. Re-intubation rate was 0.74%. The perioperative parameters were significantly better in success group and the safety was also demonstrated in the patients who were fast tracked successfully. To implement the practice in its full capacity and benefit, a fast track protocol needs to be devised to standardize the current practices and to disseminate the strategy among junior anaesthesiologists, perfusionists and nursing staff.
Secure FAST: Security Enhancement in the NATO Time Sensitive Targeting Tool
2010-11-01
designed to aid in the tracking and prosecuting of Time Sensitive Targets. The FAST tool provides user level authentication and authorisation in terms...level authentication and authorisation in terms of security. It uses operating system level security but does not provide application level security for...and collaboration tool, designed to aid in the tracking and prosecuting of Time Sensitive Targets. The FAST tool provides user level authentication and
Gu, Zhenyu; Rao, Maithreyi K.; Forsyth, William R.
2009-01-01
The structures of partially-folded states appearing during the folding of a (βα)8 TIM barrel protein, the indole-3-glycerol phosphate synthase from S. solfataricus (sIGPS), was assessed by hydrogen exchange mass spectrometry (HX-MS) and Gō-model simulations. HX-MS analysis of the peptic peptides derived from the pulse-labeled product of the sub-millisecond folding reaction from the urea-denatured state revealed strong protection in the (βα)4 region, modest protection in the neighboring (βα)1–3 and (βα)5β6 segments and no significant protection in the remaining N- and C-terminal segments. These results demonstrate that this species is not a collapsed form of the unfolded state under native-favoring conditions nor is it the native state formed via fast-track folding. However, the striking contrast of these results with the strong protection observed in the (βα)2–5β6 region after 5 s of folding demonstrates that these species represent kinetically-distinct folding intermediates that are not identical as previously thought. A re-examination of the kinetic folding mechanism by chevron analysis of fluorescence data confirmed distinct roles for these two species: the burst-phase intermediate is predicted to be a misfolded, off-pathway intermediate while the subsequent 5 s intermediate corresponds to an on-pathway equilibrium intermediate. Comparison with the predictions using a Cα Gō-model simulation of the kinetic folding reaction for sIGPS shows good agreement with the core of structure offering protection against exchange in the on-pathway intermediate(s). Because the native-centric Gō-model simulations do not explicitly include sequence-specific information, the simulation results support the hypothesis that the topology of TIM barrel proteins is a primary determinant of the folding free energy surface for the productive folding reaction. The early misfolding reaction must involve aspects of non-native structure not detected by the Gō-model simulation. PMID:17942114
Fast-track program vs traditional care in surgery for gastric cancer.
Chen, Zhi-Xing; Liu, Ae-Huey Jennifer; Cen, Ying
2014-01-14
To systematically review the evidence for the effectiveness of fast-track program vs traditional care in laparoscopic or open surgery for gastric cancer. PubMed, Embase and the Cochrane library databases were electronically searched for published studies between January 1995 and April 2013, and only randomized trials were included. The references of relevant studies were manually searched for further studies that may have been missed. Search terms included "gastric cancer", "fast track" and "enhanced recovery". Five outcome variables were considered most suitable for analysis: postoperative hospital stay, medical cost, duration to first flatus, C-reactive protein (CRP) level and complications. Postoperative hospital stay was calculated from the date of operation to the date of discharge. Fixed effects model was used for meta-analysis. Compared with traditional care, fast-track program could significantly decrease the postoperative hospital stay [weighted mean difference (WMD) = -1.19, 95%CI: -1.79--0.60, P = 0.0001, fixed model], duration to first flatus (WMD = -6.82, 95%CI: -11.51--2.13, P = 0.004), medical costs (WMD = -2590, 95%CI: -4054--1126, P = 0.001), and the level of CRP (WMD = -17.78, 95%CI: -32.22--3.35, P = 0.0001) in laparoscopic surgery for gastric cancer. In open surgery for gastric cancer, fast-track program could also significantly decrease the postoperative hospital stay (WMD = -1.99, 95%CI: -2.09--1.89, P = 0.0001), duration to first flatus (WMD = -12.0, 95%CI: -18.89--5.11, P = 0.001), medical cost (WMD = -3674, 95%CI: -5025--2323, P = 0.0001), and the level of CRP (WMD = -27.34, 95%CI: -35.42--19.26, P = 0.0001). Furthermore, fast-track program did not significantly increase the incidence of complication (RR = 1.39, 95%CI: 0.77-2.51, P = 0.27, for laparoscopic surgery; and RR = 1.52, 95%CI: 0.90-2.56, P = 0.12, for open surgery). Our overall results suggested that compared with traditional care, fast-track program could result in shorter postoperative hospital stay, less medical costs, and lower level of CRP, with no more complications occurring in both laparoscopic and open surgery for gastric cancer.
Guldbrandt, Louise Mahncke; Fenger-Grøn, Morten; Rasmussen, Torben Riis; Jensen, Henry; Vedsted, Peter
2015-01-22
Lung cancer stage at diagnosis predicts possible curative treatment. In Denmark and the UK, lung cancer patients have lower survival rates than citizens in most other European countries, which may partly be explained by a comparatively longer diagnostic interval in these two countries. In Denmark, a pathway was introduced in 2008 allowing general practitioners (GPs) to refer patients suspected of having lung cancer directly to fast-track diagnostics. However, symptom presentation of lung cancer in general practice is known to be diverse and complex, and systematic knowledge of the routes to diagnosis is needed to enable earlier lung cancer diagnosis in Denmark. This study aims to describe the routes to diagnosis, the diagnostic activity preceding diagnosis and the diagnostic intervals for lung cancer in the Danish setting. We conducted a national registry-based cohort study on 971 consecutive incident lung cancer patients in 2010 using data from national registries and GP questionnaires. GPs were involved in 68.3% of cancer patients' diagnostic pathways, and 27.4% of lung cancer patients were referred from the GP to fast-track diagnostic work-up. A minimum of one X-ray was performed in 85.6% of all cases before diagnosis. Patients referred through a fast-track route more often had diagnostic X-rays (66.0%) than patients who did not go through fast-track (49.4%). Overall, 33.6% of all patients had two or more X-rays performed during the 90 days before diagnosis. Patients whose symptoms were interpreted as non-alarm symptoms or who were not referred to fast-track were more likely to experience a long diagnostic interval than patients whose symptoms were interpreted as alarm symptoms or who were referred to fast-track. Lung cancer patients followed several diagnostic pathways. The existing fast-track pathway must be supplemented to ensure earlier detection of lung cancer. The high incidence of multiple X-rays warrants a continued effort to develop more accurate lung cancer tests for use in primary care.
Accelerated Leadership Development: Fast Tracking School Leaders
ERIC Educational Resources Information Center
Earley, Peter; Jones, Jeff
2010-01-01
"Accelerated Leadership Development" captures and communicates the lessons learned from successful fast-track leadership programmes in the private and public sector, and provides a model which schools can follow and customize as they plan their own leadership development strategies. As large numbers of headteachers and other senior staff…
Fast Track Option: An Accelerated Associate's Degree Program.
ERIC Educational Resources Information Center
Price, J. Randall
1998-01-01
Alternative instructional delivery options such as self-paced and flexible enrollment courses are designed to increase enrollment, promote retention, and encourage student success without lowering academic standards. The Fast Track Associate's Degree Program, developed by a team of faculty, staff, and administrators at Richland Community College,…
Fast track surgery: a clinical audit.
Carter, Jonathan; Szabo, Rebecca; Sim, Wee Wee; Pather, Selvan; Philp, Shannon; Nattress, Kath; Cotterell, Stephen; Patel, Pinki; Dalrymple, Chris
2010-04-01
Fast track surgery is a concept that utilises a variety of techniques to reduce the surgical stress response, allowing a shortened length of stay, improved outcomes and decreased time to full recovery. To evaluate a peri-operative Fast Track Surgical Protocol (FTSP) in patients referred for abdominal surgery. All patients undergoing a laparotomy over a 12-month period were entered prospectively on a clinical database. Data were retrospectively analysed. Over the study period, 72 patients underwent a laparotomy. Average patient age was 54 years and average weight and BMI were 67.2 kg and 26 respectively. Sixty three (88%) patients had a vertical midline incision (VMI). There were no intraoperative blood transfusions. The median length of stay (LOS) was 3.0 days. Thirty eight patients (53%) were discharged on or before post op day 3, seven (10%) of whom were discharged on postoperative day 2. On stepwise regression analysis, the following were found to be independently associated with reduced LOS: able to tolerate early enteral nutrition, good performance status, use of COX inhibitor and transverse incision. In comparison with colleagues at the SGOG not undertaking FTS for their patients, the authors' LOS was lower and the RANZCOG modified Quality Indicators (QI's) did not demonstrate excess morbidity. Patients undergoing fast track surgery can be discharged from hospital with a reduced LOS, without an increased readmission rate and with comparative outcomes to non-fast tracked patients.
Fast Track to Success: Top Young Trainers 2012
ERIC Educational Resources Information Center
Freifeld, Lorri
2012-01-01
Supercharged. High-performers. Leaders of the pack. This article presents "Training" magazine's 2012 Top Young Trainers--those high-potential training professionals who are on the fast track to success. For the fifth year, "Training" magazine is pleased to recognize the outstanding talents, accomplishments, and leadership exhibited by 40 learning…
Jackson, Carrie N.; Dussias, Paola E.; Hristova, Adelina
2012-01-01
This study uses eye-tracking to examine the processing of case-marking information in ambiguous subject- and object-first wh-questions in German. The position of the lexical verb was also manipulated via verb tense to investigate whether verb location influences how intermediate L2 learners process L2 sentences. Results show that intermediate L2 German learners were sensitive to case-marking information, exhibiting longer processing times on subject-first than object-first sentences, regardless of verb location. German native speakers exhibited the opposite word order preference, with longer processing times on object-first than subject-first sentences, replicating previous findings. These results are discussed in light of current L2 processing research, highlighting how methodological constraints influence researchers’ abilities to measure the on-line processing of morphosyntactic information among intermediate L2 learners. PMID:23493761
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sherrett, R.R.
This study investigates the relationship between NATO's decision to approach the problem created by the intermediate-range nuclear force superiority of the Soviets and the eventual signing of the INF Treaty by the United States and the Soviet Union. The concept presented is that by adopting the dual track decision, (a track for negotiations and a simultaneous track for fielding U.S. INF missiles), the United States was eventually able to conduct arms negotiations from a position of strength. In this way a significant contribution to the INF Treaty negotiation process was made. The study examines the position of each principal priormore » to the dual track decision, examines the role each played in that decision, and looks at the actions taken following the implementation of the dual track decision. The study also presents the nuclear background of NATO, and also examines the INF negotiations in some detail. The conclusions provide the current status of the INF Treaty implementation and outlines some lessons which could be applied to future negotiations of this type. Intermediate-range Nuclear Forces, INF Treaty, GLCM, PIT, Pershing II missiles, Ground Launched Cruise Missiles, Dual Track Decision, Nuclear arms negotiations.« less
2000-01-01
Fast Track is a multisite, multicomponent preventive intervention for young children at high risk for long-term antisocial behavior. Based on a comprehensive developmental model, this intervention includes a universal-level classroom program plus social-skill training, academic tutoring, parent training, and home visiting to improve competencies and reduce problems in a high-risk group of children selected in kindergarten. The theoretical principles and clinical strategies utilized in the Fast Track Project are described to illustrate the interplay between basic developmental research, the understanding of risk and protective factors, and a research-based model of preventive intervention that integrates universal and indicated models of prevention.
"Joined up" Thinking? Unsupported "Fast-Track" Transitions in the Context of Parental Substance Use
ERIC Educational Resources Information Center
Wilson, Sarah; Cunningham-Burley, Sarah; Bancroft, Angus; Backett-Milburn, Kathryn
2008-01-01
Recent policy responses to the risks entailed in "fast-track" school-work transitions have targeted careleavers and young people identified as "not in education, employment or training" (NEET). However, this approach has been criticised as diverting attention away from the fragile circumstances of others who may receive little…
Preventing Serious Conduct Problems in School-Age Youth: The Fast Track Program
ERIC Educational Resources Information Center
Slough, Nancy M.; McMahon, Robert J.; Bierman, Karen L.; Coie, John D.; Dodge, Kenneth A.; Foster, E. Michael; Greenberg, Mark T.; Lochman, John E.; McMahon, Robert J.; Pinderhughes, Ellen E.
2008-01-01
Children with early-starting conduct problems have a very poor prognosis and exact a high cost to society. The Fast Track project is a multisite, collaborative research project investigating the efficacy of a comprehensive, long-term, multicomponent intervention designed to "prevent" the development of serious conduct problems in high-risk…
ERIC Educational Resources Information Center
Bierman, Karen L.; Coie, John D.; Dodge, Kenneth A.; Greenberg, Mark T.; Lochman, John E.; McMahon, Robert J.; Pinderhughes, Ellen
2010-01-01
Objective: This article examines the impact of a universal social-emotional learning program, the Fast Track PATHS (Promoting Alternative Thinking Strategies) curriculum and teacher consultation, embedded within the Fast Track selective prevention model. Method: The longitudinal analysis involved 2,937 children of multiple ethnicities who remained…
Fast track pathway for perforated appendicitis.
Frazee, Richard; Abernathy, Stephen; Davis, Matthew; Isbell, Travis; Regner, Justin; Smith, Randall
2017-04-01
Perforated appendicitis is associated with an increased morbidity and length of stay. "Fast track" protocols have demonstrated success in shortening hospitalization without increasing morbidity for a variety of surgical processes. This study evaluates a fast track pathway for perforated appendicitis. In 2013, a treatment pathway for perforated appendicitis was adopted by the Acute Care Surgery Service for patients having surgical management of perforated appendicitis. Interval appendectomy was excluded. Patients were treated initially with intravenous antibiotics and transitioned to oral antibiotics and dismissed when medically stable and tolerating oral intake. A retrospective review of patients managed on the fast track pathway was undertaken to analyze length of stay, morbidity, and readmissions. Thirty-four males and twenty-one females with an average age of 46.8 years underwent laparoscopic appendectomy for perforated appendicitis between January 2013 and December 2014. Pre-existing comorbidities included hypertension 42%, diabetes mellitus 11%, COPD 5% and heart disease 2%. No patient had conversion to open appendectomy. Average length of stay was 2.67 days and ranged from 1 to 12 days (median 2 days). Postoperative morbidity was 20% and included abscess (6 patients), prolonged ileus (3 patients), pneumonia (1 patient), and congestive heart failure (1 patient). Five patients were readmitted for abscess (3 patients), congestive heart failure (1 patient), and pneumonia (1 patient). A fast track pathway for perforated appendicitis produced shorter length of stay and acceptable postoperative morbidity and readmission. This offers the potential for significant cost savings over current national practice patterns. Copyright © 2016 Elsevier Inc. All rights reserved.
Finite-time control for nonlinear spacecraft attitude based on terminal sliding mode technique.
Song, Zhankui; Li, Hongxing; Sun, Kaibiao
2014-01-01
In this paper, a fast terminal sliding mode control (FTSMC) scheme with double closed loops is proposed for the spacecraft attitude control. The FTSMC laws are included both in an inner control loop and an outer control loop. Firstly, a fast terminal sliding surface (FTSS) is constructed, which can drive the inner loop tracking-error and the outer loop tracking-error on the FTSS to converge to zero in finite time. Secondly, FTSMC strategy is designed by using Lyaponov's method for ensuring the occurrence of the sliding motion in finite time, which can hold the character of fast transient response and improve the tracking accuracy. It is proved that FTSMC can guarantee the convergence of tracking-error in both approaching and sliding mode surface. Finally, simulation results demonstrate the effectiveness of the proposed control scheme. © 2013 ISA. Published by Elsevier Ltd. All rights reserved.
Fast emulation of track reconstruction in the CMS simulation
NASA Astrophysics Data System (ADS)
Komm, Matthias; CMS Collaboration
2017-10-01
Simulated samples of various physics processes are a key ingredient within analyses to unlock the physics behind LHC collision data. Samples with more and more statistics are required to keep up with the increasing amounts of recorded data. During sample generation, significant computing time is spent on the reconstruction of charged particle tracks from energy deposits which additionally scales with the pileup conditions. In CMS, the FastSimulation package is developed for providing a fast alternative to the standard simulation and reconstruction workflow. It employs various techniques to emulate track reconstruction effects in particle collision events. Several analysis groups in CMS are utilizing the package, in particular those requiring many samples to scan the parameter space of physics models (e.g. SUSY) or for the purpose of estimating systematic uncertainties. The strategies for and recent developments in this emulation are presented, including a novel, flexible implementation of tracking emulation while retaining a sufficient, tuneable accuracy.
Cheong, Fook Chiong; Wong, Chui Ching; Gao, YunFeng; Nai, Mui Hoon; Cui, Yidan; Park, Sungsu; Kenney, Linda J.; Lim, Chwee Teck
2015-01-01
Tracking fast-swimming bacteria in three dimensions can be extremely challenging with current optical techniques and a microscopic approach that can rapidly acquire volumetric information is required. Here, we introduce phase-contrast holographic video microscopy as a solution for the simultaneous tracking of multiple fast moving cells in three dimensions. This technique uses interference patterns formed between the scattered and the incident field to infer the three-dimensional (3D) position and size of bacteria. Using this optical approach, motility dynamics of multiple bacteria in three dimensions, such as speed and turn angles, can be obtained within minutes. We demonstrated the feasibility of this method by effectively tracking multiple bacteria species, including Escherichia coli, Agrobacterium tumefaciens, and Pseudomonas aeruginosa. In addition, we combined our fast 3D imaging technique with a microfluidic device to present an example of a drug/chemical assay to study effects on bacterial motility. PMID:25762336
Real-time and high accuracy frequency measurements for intermediate frequency narrowband signals
NASA Astrophysics Data System (ADS)
Tian, Jing; Meng, Xiaofeng; Nie, Jing; Lin, Liwei
2018-01-01
Real-time and accurate measurements of intermediate frequency signals based on microprocessors are difficult due to the computational complexity and limited time constraints. In this paper, a fast and precise methodology based on the sigma-delta modulator is designed and implemented by first generating the twiddle factors using the designed recursive scheme. This scheme requires zero times of multiplications and only half amounts of addition operations by using the discrete Fourier transform (DFT) and the combination of the Rife algorithm and Fourier coefficient interpolation as compared with conventional methods such as DFT and Fast Fourier Transform. Experimentally, when the sampling frequency is 10 MHz, the real-time frequency measurements with intermediate frequency and narrowband signals have a measurement mean squared error of ±2.4 Hz. Furthermore, a single measurement of the whole system only requires approximately 0.3 s to achieve fast iteration, high precision, and less calculation time.
[Phosphatase activity in Amoeba proteus at pH 9.0].
Sopina, V A
2007-01-01
In the free-living amoeba Amoeba proteus (strain B), after PAAG disk-electrophoresis of the homogenate supernatant, at using 1-naphthyl phosphate as a substrate and pH 9.0, three forms of phosphatase activity were revealed; they were arbitrarily called "fast", "intermediate", and "slow" phosphatases. The fast phosphatase has been established to be a fraction of lysosomal acid phosphatase that preserves some low activity at alkaline pH. The question as to which particular class the intermediate phosphatase belongs to has remained unanswered: it can be both acid phosphatase and protein tyrosine phosphatase (PTP). Based on data of inhibitor analysis, large substrate specificity, results of experiments with reactivation by Zn ions after inactivation with EDTA, other than in the fast and intermediate phosphatases localization in the amoeba cell, it is concluded that only slow phosphatase can be classified as alkaline phosphatase (EC 3.1.3.1).
DeFina, Laura F; Vega, Gloria Lena; Leonard, David; Grundy, Scott M
2012-12-01
To determine risk for type 2 diabetes in subjects with fasting glucose levels in the ranges of normoglycemia, mild hyperglycemia, and intermediate hyperglycemia and to assess the effect of obesity and metabolic syndrome on this risk. Incidence of type 2 diabetes mellitus was evaluated in 28,209 relatively healthy subjects participating in the Cooper Center Longitudinal Study. They were included in the study if they had more than 1 fasting plasma glucose measurement, anthropometry, and other parameters of interest. Three subgroups were identified: normoglycemic (<5.6 mmol/L), mild hyperglycemia (5.6-6.0 mmol/L), and intermediate hyperglycemia (6.1-7.0 mmol/L). Diabetes incidence was calculated in categories of sex, age, obesity, and metabolic syndrome status. Incident diabetes was assessed at the earliest clinic visit at which the individual exhibited a blood glucose level of more than 7.0 mmol/L or reported a diagnosis of diabetes. Thirty-one percent of men and 15.9% of women had mild hyperglycemia and 11.9% of men and 3.6% of women had intermediate hyperglycemia. Yearly conversion rates to diabetes were low in individuals with normoglycemia and mild hyperglycemia but were strikingly higher in those with intermediate hyperglycemia. In subjects with intermediate hyperglycemia, presence of obesity and/or metabolic syndrome doubled conversion rates to diabetes. This study showed a marked difference in outcomes in subjects with mild and intermediate hyperglycemia. Moreover, obesity and metabolic syndrome were associated with strikingly elevated risk for diabetes in subjects with intermediate hyperglycemia. Thus intermediate hyperglycemia plus obesity/metabolic syndrome seemingly justifies intensive clinical intervention for prevention of both diabetes and cardiovascular disease.
Brown, Nicholas R.; Powers, Jeffrey J.; Feng, B.; ...
2015-05-21
This paper presents analyses of possible reactor representations of a nuclear fuel cycle with continuous recycling of thorium and produced uranium (mostly U-233) with thorium-only feed. The analysis was performed in the context of a U.S. Department of Energy effort to develop a compendium of informative nuclear fuel cycle performance data. The objective of this paper is to determine whether intermediate spectrum systems, having a majority of fission events occurring with incident neutron energies between 1 eV and 10 5 eV, perform as well as fast spectrum systems in this fuel cycle. The intermediate spectrum options analyzed include tight latticemore » heavy or light water-cooled reactors, continuously refueled molten salt reactors, and a sodium-cooled reactor with hydride fuel. All options were modeled in reactor physics codes to calculate their lattice physics, spectrum characteristics, and fuel compositions over time. Based on these results, detailed metrics were calculated to compare the fuel cycle performance. These metrics include waste management and resource utilization, and are binned to accommodate uncertainties. The performance of the intermediate systems for this selfsustaining thorium fuel cycle was similar to a representative fast spectrum system. However, the number of fission neutrons emitted per neutron absorbed limits performance in intermediate spectrum systems.« less
Developmental Mediation of Genetic Variation in Response to the Fast Track Prevention Program
Albert, Dustin; Belsky, Daniel W.; Crowley, D. Max; Bates, John E.; Pettit, Gregory S.; Lansford, Jennifer E.; Dick, Danielle; Dodge, Kenneth A.
2015-01-01
We conducted a developmental analysis of genetic moderation of the effect of the Fast Track intervention on adult externalizing psychopathology. The Fast Track intervention enrolled 891 children at high risk to develop externalizing behavior problems when they were in kindergarten. Half of the enrolled children were randomly assigned to receive 10 years of treatment with a range of services and resources provided to the children and their families and the other half to usual care (controls). We previously showed that the effect of the Fast Track intervention on participants’ risk of externalizing psychopathology at age 25 years was moderated by a variant in the Glucocorticoid Receptor Gene (NR3C1). Children who carried copies of the A-allele of the single-nucleotide polymorphism rs10482672 had the highest risk of externalizing psychopathology if they were in the control arm of the trial and the lowest risk of externalizing psychopathology if they were in the treatment arm. In this study, we test a developmental hypothesis about the origins of this for-better-and-for-worse gene-by-intervention interaction (GxI): That the observed GxI effect on adult psychopathology is mediated by the proximal impact of intervention on childhood externalizing problems and adolescent substance use and delinquency. We analyzed longitudinal data tracking the 270 European-American children in the Fast Track RCT with available genetic information (129 intervention children and 141 control-group peers, 69% male) from kindergarten through age 25 years. Results show that the same pattern of “for-better-and-for-worse” susceptibility to intervention observed at the age-25 follow-up was evident already during childhood. At the elementary school follow-ups and at the middle/high-school follow-ups, rs10482672 predicted better adjustment among children receiving the Fast Track intervention, and worse adjustment among children in the control condition. In turn, these proximal GxI effects early in development mediated the ultimate GxI effect on externalizing psychopathology at age 25 years. We discuss the contribution of these findings to the growing literature on genetic susceptibility to environmental intervention. PMID:25640832
Wanden-Berghe, Carmina; Sanz-Valero, Javier; Arroyo-Sebastián, Antonio; Cheikh-Moussa, Kamila; Moya-Forcen, Pedro
2016-07-19
Introducción: Preoperative nutritional status (NS) has consequences on postoperative (POSTOP) recovery. Our aim was to systematically review the nutritional interventions (NI) in Fast-Track protocols for colorectal cancer surgery and assess morbidity-mortality and patient´s recovery. Systematic review of scientific literature after consulting bibliographic databases: Medline, The Cochrane Library, Scopus, Embase, Web of Science, Institute for Scientific Information, Latin American and Caribbean Health Sciences Literature, The Cumulative Index to Nursing and Allied Health Literature. MeSH Descriptors: "Colorectal Surgery", "Fast-Track", "Perioperative Care", "Nutrition Therapy" and "Enhanced recovery programme". Filters: "Humans", Adult (19+ years) and "Clinical Trial". Variables POSTOP outcomes: bowel recovery (BR), hospital stay (HS), complications and death. Selected studies, 27, had good or excellent methodological quality. From 25 to 597 patients were included. Aged between 16-94 years, men were predominant in 66.6%. NS was evaluated in 13 studies; 7 by Body Mass Index while one by Subjective Global Assessment. One presented POSTOP data. Fast-Track groups had solids, liquids or supplements (SS) in prior 2-8 hours. SS were high in carbohydrates, immune-nutrients and non-residue. Free liquids, solids and SS intake was allowed in POSTOP. Half traditional groups fasted between 3-12 hours and resumed POSTOP food intake progressively. Fast-Track groups had early BR (p < 0.01). Traditional groups had more infections episodes, deaths and a longer HS. Great variability between NI but had a common item; early intake. Although was seen patient's recovery. Future studies with detailed NI characteristics are need. Nutritional status must be assessed for a higher acknowledgement of NI impact.
ERIC Educational Resources Information Center
Journal of the American Academy of Child & Adolescent Psychiatry, 2007
2007-01-01
Objective: This study tests the efficacy of the Fast Track Program in preventing antisocial behavior and psychiatric disorders among groups varying in initial risk. Method: Schools within four sites (Durham, NC; Nashville, TN; Seattle, WA; and rural central Pennsylvania) were selected as high-risk institutions based on neighborhood crime and…
Fast Tracking School Site Acquisition: A Perspective of an Eminent Domain Attorney.
ERIC Educational Resources Information Center
Behrens, Jerry
This paper discusses key issues in fast-tracking the acquisition of school sites in California. Discussion addresses: (1) assembling an experienced team; (2) whether the property owner is a willing or unwilling seller; (3) level of community support or opposition to the site; (4) timing and commencement of California Environmental Quality Act…
Fast Track Initiative: Building a Global Compact for Education. Education Notes
ERIC Educational Resources Information Center
Human Development Network Education, 2005
2005-01-01
This note series is intended to summarize lessons learned and key policy findings on the World Bank's work in education. "Fast Track Initiative" ("FTI") was launched in 2002 as a partnership between donor and developing countries to accelerate progress towards the Millennium Development Goal (MDG) of universal primary education. "FTI" is built on…
Electrically tunable lens speeds up 3D orbital tracking
Annibale, Paolo; Dvornikov, Alexander; Gratton, Enrico
2015-01-01
3D orbital particle tracking is a versatile and effective microscopy technique that allows following fast moving fluorescent objects within living cells and reconstructing complex 3D shapes using laser scanning microscopes. We demonstrated notable improvements in the range, speed and accuracy of 3D orbital particle tracking by replacing commonly used piezoelectric stages with Electrically Tunable Lens (ETL) that eliminates mechanical movement of objective lenses. This allowed tracking and reconstructing shape of structures extending 500 microns in the axial direction. Using the ETL, we tracked at high speed fluorescently labeled genomic loci within the nucleus of living cells with unprecedented temporal resolution of 8ms using a 1.42NA oil-immersion objective. The presented technology is cost effective and allows easy upgrade of scanning microscopes for fast 3D orbital tracking. PMID:26114037
NASA Astrophysics Data System (ADS)
Mor, Ilan; Vartsky, David; Dangendorf, Volker; Tittelmeier, Kai.; Weierganz, Mathias; Goldberg, Mark Benjamin; Bar, Doron; Brandis, Michal
2018-06-01
We describe an analysis procedure for automatic unambiguous detection of fast-neutron-induced recoil proton tracks in a micro-capillary array filled with organic liquid scintillator. The detector is viewed by an intensified CCD camera. This imaging neutron detector possesses the capability to perform high position-resolution (few tens of μm), energy-dispersive transmission-imaging using ns-pulsed beams. However, when operated with CW or DC beams, it also features medium-quality spectroscopic capabilities for incident neutrons in the energy range 2-20 MeV. In addition to the recoil proton events which display a continuous extended track structure, the raw images exhibit complex ion-tracks from nuclear interactions of fast-neutrons in the scintillator, capillaries quartz-matrix and CCD. Moreover, as expected, one also observes a multitude of isolated scintillation spots of varying intensity (henceforth denoted "blobs") that originate from several different sources, such as: fragmented proton tracks, gamma-rays, heavy-ion reactions as well as events and noise that occur in the image-intensifier and CCD. In order to identify the continuous-track recoil proton events and distinguish them from all these background events, a rapid, computerized and automatic track-recognition-procedure was developed. Based on an appropriately weighted analysis of track parameters such as: length, width, area and overall light intensity, the method is capable of distinguishing a single continuous-track recoil proton from typically surrounding several thousands of background events that are found in each CCD frame.
Implementation and audit of 'Fast-Track Surgery' in gynaecological oncology surgery.
Sidhu, Verinder S; Lancaster, Letitia; Elliott, David; Brand, Alison H
2012-08-01
Fast-track surgery is a multidisciplinary approach to surgery that results in faster recovery from surgery and decreased length of stay (LOS). The aims of this study were as follows: (i) to report on the processes required for the introduction of fast-track surgery to a gynaecological oncology unit and (ii) to report the results of a clinical audit conducted after the protocol's implementation. A fast-track protocol, specific to our unit, was developed after a series of multidisciplinary meetings. The protocol, agreed upon by those involved in the care of women in our unit, was then introduced into clinical practice. An audit was conducted of all women undergoing laparotomy, with known or suspected malignancy. Information on LOS, complication and readmission rates was collected. Descriptive statistics and Poisson regression were used for statistical analysis. The developed protocol involved a multidisciplinary approach to pre-, intra- and postoperative care. The audit included 104 consecutive women over a 6-month period, who were followed for 6 weeks postoperatively. The median LOS was 4 days. The readmission rate was 7% and the complication rate was 19% (1% intraoperative, 4% major and 14% minor). Multivariate analysis revealed that increased duration of surgery and increasing age were predictors of longer LOS. The development of a fast-track protocol is achievable in a gynaecological oncology unit, with input from a multidisciplinary team. Effective implementation of the protocol can result in a short LOS, with acceptable complication and readmission rates when applied non-selectively to gynaecological oncology patients. © 2012 The Authors ANZJOG © 2012 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.
Berthelsen, Connie Bøttcher; Lindhardt, Tove; Frederiksen, Kirsten
2014-12-01
To generate a substantive grounded theory of relatives' pattern of behaviour in older patients' fast-track treatment programmes during total hip or knee replacement. Fast-track treatment programmes are designed to make total hip and knee replacements more efficient through recovery improvements. The support of relatives during older patients' trajectory is important. However, knowledge is needed on the relatives' pattern of behaviour to strengthen their involvement in fast-track treatment programmes. We used a Glaserian grounded theory approach based on a systematic generation of theory from data to explain the latent pattern of behaviour of relatives. Data were collected from 2010-2011 in orthopaedic wards at two Danish university hospitals and consisted of 14 non-participant observations, 14 postobservational interviews and five interviews. Seven relatives of patients over 70 years of age participated. The constant comparative method was the guiding principle for simultaneous data collection, data analysis and coding, while theoretically sampling and writing memos. Maintaining Unity emerged as the relatives' pattern of behaviour through which they resolved their main concern: preventing the patients from feeling alone. The relatives resolved their main concern through three interchangeable behavioural modes: Protecting Mode, by providing loving and respectful support; Substituting Mode, with practical and cognitive support; and an Adapting Mode, by trying to fit in with the patients' and health professionals' requirements. The substantive theory of Maintaining Unity offers knowledge of relatives' strong desire to provide compassionate and loving support for the older patients during fast-track treatment programmes. © 2014 John Wiley & Sons Ltd.
Fast left ventricle tracking in CMR images using localized anatomical affine optical flow
NASA Astrophysics Data System (ADS)
Queirós, Sandro; Vilaça, João. L.; Morais, Pedro; Fonseca, Jaime C.; D'hooge, Jan; Barbosa, Daniel
2015-03-01
In daily cardiology practice, assessment of left ventricular (LV) global function using non-invasive imaging remains central for the diagnosis and follow-up of patients with cardiovascular diseases. Despite the different methodologies currently accessible for LV segmentation in cardiac magnetic resonance (CMR) images, a fast and complete LV delineation is still limitedly available for routine use. In this study, a localized anatomically constrained affine optical flow method is proposed for fast and automatic LV tracking throughout the full cardiac cycle in short-axis CMR images. Starting from an automatically delineated LV in the end-diastolic frame, the endocardial and epicardial boundaries are propagated by estimating the motion between adjacent cardiac phases using optical flow. In order to reduce the computational burden, the motion is only estimated in an anatomical region of interest around the tracked boundaries and subsequently integrated into a local affine motion model. Such localized estimation enables to capture complex motion patterns, while still being spatially consistent. The method was validated on 45 CMR datasets taken from the 2009 MICCAI LV segmentation challenge. The proposed approach proved to be robust and efficient, with an average distance error of 2.1 mm and a correlation with reference ejection fraction of 0.98 (1.9 +/- 4.5%). Moreover, it showed to be fast, taking 5 seconds for the tracking of a full 4D dataset (30 ms per image). Overall, a novel fast, robust and accurate LV tracking methodology was proposed, enabling accurate assessment of relevant global function cardiac indices, such as volumes and ejection fraction
NASA Astrophysics Data System (ADS)
Webster, Jordan
2017-01-01
Dense track environments in pp collisions at the Large Hadron Collider (LHC) motivate the use of triggers with dedicated hardware for fast track reconstruction. The ATLAS Collaboration is in the process of implementing a Fast Tracker (FTK) trigger upgrade, in which Content Addressable Memories (CAMs) will be used to rapidly match hit patterns with large banks of simulated tracks. The FTK CAMs are produced primarily at the University of Pisa. However, commercial CAM technology is rapidly developing due to applications in computer networking devices. This poster presents new studies comparing FTK CAMs to cutting-edge ternary CAMs developed by Cavium. The comparison is intended to guide the design of future track-based trigger systems for the next Phase at the LHC.
NASA Technical Reports Server (NTRS)
1996-01-01
The NASA Fast Track Study supports the efforts of a Special Study Group (SSG) made up of members of the Advanced Project Management Class number 23 (APM-23) that met at the Wallops Island Management Education Center from April 28 - May 8, 1996. Members of the Class expressed interest to Mr. Vem Weyers in having an input to the NASA Policy Document (NPD) 7120.4, that will replace NASA Management Institute (NMI) 7120.4, and the NASA Program/Project Management Guide. The APM-23 SSG was tasked with assisting in development of NASA policy on managing Fast Track Projects, defined as small projects under $150 million and completed within three years. 'Me approach of the APM-23 SSG was to gather data on successful projects working in a 'Better, Faster, Cheaper' environment, within and outside of NASA and develop the Fast Track Project section of the NASA Program/Project Management Guide. Fourteen interviews and four other data gathering efforts were conducted by the SSG, and 16 were conducted by Strategic Resources, Inc. (SRI), including five interviews at the Jet Propulsion Laboratory (JPL) and one at the Applied Physics Laboratory (APL). The interviews were compiled and analyzed for techniques and approaches commonly used to meet severe cost and schedule constraints.
Fast-track cardiac care for adult cardiac surgical patients.
Zhu, Fang; Lee, Anna; Chee, Yee Eot
2012-10-17
Fast-track cardiac care is a complex intervention involving several components of care during cardiac anaesthesia and in the postoperative period, all with the ultimate aim of early extubation after surgery, to reduce the length of stay in the intensive care unit and in the hospital. Safe and effective fast-track cardiac care may reduce hospital costs. This is an update of a Cochrane review published in 2003. To update the evidence on the safety and effectiveness of fast-track cardiac care compared to conventional (not fast-track) care in adult patients undergoing cardiac surgery. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (2012, Issue 3), MEDLINE (January 1966 to April 2012), EMBASE (January 1980 to April 2012), CINAHL (January 1982 to April 2012), and ISI Web of Science (January 2003 to April 2012). We searched reference lists of articles and contacted experts in the field. All randomized controlled trials of adult cardiac surgical patients (coronary artery bypass grafts, aortic valve replacement, mitral valve replacement) that compared fast-track cardiac care and conventional (not fast-track) care groups were included. We focused on the following fast-track interventions that were designed for early extubation after surgery, administration of low-dose opioid based general anaesthesia during cardiac surgery and the use of a time-directed extubation protocol after surgery. The primary outcome was the risk of mortality. Secondary outcomes included postoperative complications, reintubation within 24 hours of surgery, time to extubation, length of stay in the intensive care unit and in the hospital, quality of life after surgery and hospital costs. Two review authors independently assessed trial quality and extracted the data. Study authors were contacted for additional information. We used a random-effects model and reported relative risk (RR), mean difference (MD) and 95% confidence intervals (95% CI). Twenty-five trials involving 4118 patients were included in the review. There were two studies with a low risk of bias and nine studies with a high risk of bias. There were no differences in the risk of mortality within the first year after surgery between low-dose versus high-dose opioid based general anaesthesia groups (RR 0.58, 95% CI 0.28 to 1.18) and between early extubation protocol versus usual care groups (RR 0.84, 95% CI 0.40 to 1.75).There were no significant differences between low-dose versus high-dose opioid based anaesthesia groups for postoperative complications: myocardial infarction (RR 0.98, 95% CI 0.48 to 1.99), reintubation (RR 1.77, 95% CI 0.38 to 8.27), acute renal failure (RR 1.19, 95% CI 0.33 to 4.33), major bleeding (RR 0.48, 95% CI 0.16 to 1.44), and stroke (RR 1.17, 95% CI 0.36 to 3.78). Compared to the usual care, there were no significant differences in the risk of postoperative complications associated with early extubation: myocardial infarction (RR 0.94, 95% CI 0.55 to 1.60), reintubation (RR 1.91, 95% CI 0.90 to 4.07), acute renal failure (RR 0.77, 95% CI 0.19 to 3.10), major bleeding (RR 0.80, 95% CI 0.45 to 1.44), stroke (RR 0.87, 95% CI 0.31 to 2.46), major sepsis (RR 1.25, 95% CI 0.08 to 19.75) and wound infection (RR 0.67, 95% CI 0.25 to 1.83).Although there were high levels of heterogeneity, both low-dose opioid anaesthesia and the use of time-directed extubation protocols were associated with reductions in the time to extubation (3.0 to 10.5 hours) and in the length of stay in the intensive care unit (0.4 to 8.7 hours). However, these fast-track care interventions were not associated with reductions in the total length of stay in hospital. One high quality cost-effectiveness analysis included in a randomized controlled trial showed that early extubation was likely to be cost-effective. The use of low-dose opioid based general anaesthesia and time-directed protocols for fast-track interventions have similar risks of mortality and major postoperative complications to conventional (not fast-track) care, and therefore appear to be safe in patients considered to be at low to moderate risk. These fast-track interventions reduced the time to extubation and shortened the length of stay in the intensive care unit, but did not reduce the length of stay in the hospital.
Fast Markerless Tracking for Augmented Reality in Planar Environment
NASA Astrophysics Data System (ADS)
Basori, Ahmad Hoirul; Afif, Fadhil Noer; Almazyad, Abdulaziz S.; AbuJabal, Hamza Ali S.; Rehman, Amjad; Alkawaz, Mohammed Hazim
2015-12-01
Markerless tracking for augmented reality should not only be accurate but also fast enough to provide a seamless synchronization between real and virtual beings. Current reported methods showed that a vision-based tracking is accurate but requires high computational power. This paper proposes a real-time hybrid-based method for tracking unknown environments in markerless augmented reality. The proposed method provides collaboration of vision-based approach with accelerometers and gyroscopes sensors as camera pose predictor. To align the augmentation relative to camera motion, the tracking method is done by substituting feature-based camera estimation with combination of inertial sensors with complementary filter to provide more dynamic response. The proposed method managed to track unknown environment with faster processing time compared to available feature-based approaches. Moreover, the proposed method can sustain its estimation in a situation where feature-based tracking loses its track. The collaboration of sensor tracking managed to perform the task for about 22.97 FPS, up to five times faster than feature-based tracking method used as comparison. Therefore, the proposed method can be used to track unknown environments without depending on amount of features on scene, while requiring lower computational cost.
NASA Astrophysics Data System (ADS)
Hemberger, Patrick; Custodis, Victoria B. F.; Bodi, Andras; Gerber, Thomas; van Bokhoven, Jeroen A.
2017-06-01
Catalytic fast pyrolysis is a promising way to convert lignin into fine chemicals and fuels, but current approaches lack selectivity and yield unsatisfactory conversion. Understanding the pyrolysis reaction mechanism at the molecular level may help to make this sustainable process more economic. Reactive intermediates are responsible for product branching and hold the key to unveiling these mechanisms, but are notoriously difficult to detect isomer-selectively. Here, we investigate the catalytic pyrolysis of guaiacol, a lignin model compound, using photoelectron photoion coincidence spectroscopy with synchrotron radiation, which allows for isomer-selective detection of reactive intermediates. In combination with ambient pressure pyrolysis, we identify fulvenone as the central reactive intermediate, generated by catalytic demethylation to catechol and subsequent dehydration. The fulvenone ketene is responsible for the phenol formation. This technique may open unique opportunities for isomer-resolved probing in catalysis, and holds the potential for achieving a mechanistic understanding of complex, real-life catalytic processes.
An Optimal Control Modification to Model-Reference Adaptive Control for Fast Adaptation
NASA Technical Reports Server (NTRS)
Nguyen, Nhan T.; Krishnakumar, Kalmanje; Boskovic, Jovan
2008-01-01
This paper presents a method that can achieve fast adaptation for a class of model-reference adaptive control. It is well-known that standard model-reference adaptive control exhibits high-gain control behaviors when a large adaptive gain is used to achieve fast adaptation in order to reduce tracking error rapidly. High gain control creates high-frequency oscillations that can excite unmodeled dynamics and can lead to instability. The fast adaptation approach is based on the minimization of the squares of the tracking error, which is formulated as an optimal control problem. The necessary condition of optimality is used to derive an adaptive law using the gradient method. This adaptive law is shown to result in uniform boundedness of the tracking error by means of the Lyapunov s direct method. Furthermore, this adaptive law allows a large adaptive gain to be used without causing undesired high-gain control effects. The method is shown to be more robust than standard model-reference adaptive control. Simulations demonstrate the effectiveness of the proposed method.
NASA Technical Reports Server (NTRS)
Hoffman, Edward J. (Editor); Lawbaugh, William M. (Editor)
1997-01-01
Topics Considered Include: NASA's Shared Experiences Program; Core Issues for the Future of the Agency; National Space Policy Strategic Management; ISO 9000 and NASA; New Acquisition Initiatives; Full Cost Initiative; PM Career Development; PM Project Database; NASA Fast Track Studies; Fast Track Projects; Earned Value Concept; Value-Added Metrics; Saturn Corporation Lessons Learned; Project Manager Credibility.
Bur, Isabelle M.; Zouaoui, Sonia; Fontanaud, Pierre; Coutry, Nathalie; Molino, François; Martin, Agnès O.; Mollard, Patrice; Bonnefont, Xavier
2010-01-01
The mammalian circadian system is composed of multiple peripheral clocks that are synchronized by a central pacemaker in the suprachiasmatic nuclei of the hypothalamus. This system keeps track of the external world rhythms through entrainment by various time cues, such as the light-dark cycle and the feeding schedule. Alterations of photoperiod and meal time modulate the phase coupling between central and peripheral oscillators. In this study, we used real-time quantitative PCR to assess circadian clock gene expression in the liver and pituitary gland from mice raised under various photoperiods, or under a temporal restricted feeding protocol. Our results revealed unexpected differences between both organs. Whereas the liver oscillator always tracked meal time, the pituitary circadian clockwork showed an intermediate response, in between entrainment by the light regimen and the feeding-fasting rhythm. The same composite response was also observed in the pituitary gland from adrenalectomized mice under daytime restricted feeding, suggesting that circulating glucocorticoids do not inhibit full entrainment of the pituitary clockwork by meal time. Altogether our results reveal further aspects in the complexity of phase entrainment in the circadian system, and suggest that the pituitary may host oscillators able to integrate multiple time cues. PMID:21179516
Lee, Ja Yil; Kim, D. S.
2009-01-01
Guanine-rich DNA sequences can form G-quadruplexes. These four-stranded structures are known to form in several genomic regions and to influence certain biological activities. Sometimes, the instability of G-quadruplexes causes the abnormal biological processes. Mutation is a culprit for the destabilization of G-quadruplexes, but the details of mutated G-quadruplexes are poorly understood. In this article, we investigated the conformational dynamics of single-base mutated human telomeric G-quadruplexes in the presence of K+ with single-molecule FRET spectroscopy. We observed that the replacement of single guanine by thymine in a G-track induces various folded structures, i.e. structural polymorphism. Moreover, direct observation of their dynamics revealed that a single-base mutation causes fast unfolding of folded states under physiological conditions. Furthermore, we found that the degree of destabilization varies according to mutation positions. When the central guanine of a G-track is replaced, the G-quadruplexes unfold quickly at any K+ concentrations and temperature. Meanwhile, outer-quartet mutated G-quadruplexes have heterogeneous dynamics at intermediate K+ concentrations and longstanding folded states at high K+ concentrations. Several factors such as base-stacking interaction and K+ coordination are responsible for the different dynamics according to the mutation position. PMID:19359361
Anastasiadis, Kyriakos; Asteriou, Christos; Antonitsis, Polychronis; Argiriadou, Helena; Grosomanidis, Vassilios; Kyparissa, Magdalena; Deliopoulos, Apostolos; Konstantinou, Dimitrios; Tossios, Paschalis
2013-10-01
A minimal extracorporeal circulation (MECC) circuit integrates the advances in cardiopulmonary bypass (CPB) technology into a single circuit and is associated with improved short-term outcome. The aim of this study was to prospectively evaluate MECC compared with conventional CPB in facilitating fast-track recovery after elective coronary revascularization procedures. Prospective randomized study. All patients scheduled for elective coronary artery surgery were evaluated, excluding those considered particularly high risk for fast-track failure. The fast-track protocol included careful preoperative patient selection, a fast-track anesthetic technique based on minimal administration of fentanyl, surgery at normothermia, early postoperative extubation in the cardiac recovery unit, and admission to the cardiothoracic ward within the first 24 hours postoperatively. One hundred twenty patients were assigned randomly into 2 groups (60 in each group). Group A included patients who were operated on using the MECC circuit, whereas patients in Group B underwent surgery on conventional CPB. Incidence of fast-track recovery was significantly higher in patients undergoing MECC (25% v 6.7%, p = 0.006). MECC also was recognized as a strong independent predictor of early recovery, with an odds ratio of 3.8 (p = 0.011). Duration of mechanical ventilation and cardiac recovery unit stay were significantly lower in patients undergoing MECC together with the need for blood transfusion, duration of inotropic support, need for an intra-aortic balloon pump, and development of postoperative atrial fibrillation and renal failure. MECC promotes successful early recovery after elective coronary revascularization procedures, even in a nondedicated cardiac intensive care unit setting. Copyright © 2013 Elsevier Inc. All rights reserved.
Wied, Christian; Thomsen, Morten G; Kallemose, Thomas; Myhrmann, Lis; Jensen, Lotte S; Husted, Henrik; Troelsen, Anders
2015-10-01
Fast-track TKA has significantly shortened the time available for physiotherapists to optimize knee ROM before discharge. Safety aspects concerning knee stiffness and the need for manipulation in a fast-track setting need to be illuminated. The study aims were to analyze if fast-track TKA can be considered safe considering rates of knee manipulation and if there is an association between knee ROM at time of discharge and the need for later manipulation. Primary TKAs operated in 2011 at our institution were eligible for inclusion. The study group consisted of 359 TKAs. Manipulation of the knee was performed in 21 of 359 TKAs (5.8%). Seventy-one percent were discharged with a flexion ≥70° combined with an extension deficit of ≤10°. The occurrence of MUA for these patients was 4.3%. The prevalence of knee manipulation showed a statistically significant association with the achieved knee flexion at discharge (p=0.02). Median length of stay was two days. Compared with literature findings fast-track TKA surgery may be considered safe based on the acceptable rate of knee manipulations after TKA (5.8%). We suggest ROM of ≥70° flexion combined with an extension deficit of ≤10° as an "optimal-zone" for ROM at discharge. The reason for this is the low occurrence of MUA (4.3%) in relation to the large amount of TKAs it represents (71%). The indication for MUA is multifactorial and ROM at discharge serves only as an indicator of later MUA risk. Copyright © 2015 Elsevier B.V. All rights reserved.
FAST: A fully asynchronous and status-tracking pattern for geoprocessing services orchestration
NASA Astrophysics Data System (ADS)
Wu, Huayi; You, Lan; Gui, Zhipeng; Gao, Shuang; Li, Zhenqiang; Yu, Jingmin
2014-09-01
Geoprocessing service orchestration (GSO) provides a unified and flexible way to implement cross-application, long-lived, and multi-step geoprocessing service workflows by coordinating geoprocessing services collaboratively. Usually, geoprocessing services and geoprocessing service workflows are data and/or computing intensive. The intensity feature may make the execution process of a workflow time-consuming. Since it initials an execution request without blocking other interactions on the client side, an asynchronous mechanism is especially appropriate for GSO workflows. Many critical problems remain to be solved in existing asynchronous patterns for GSO including difficulties in improving performance, status tracking, and clarifying the workflow structure. These problems are a challenge when orchestrating performance efficiency, making statuses instantly available, and constructing clearly structured GSO workflows. A Fully Asynchronous and Status-Tracking (FAST) pattern that adopts asynchronous interactions throughout the whole communication tier of a workflow is proposed for GSO. The proposed FAST pattern includes a mechanism that actively pushes the latest status to clients instantly and economically. An independent proxy was designed to isolate the status tracking logic from the geoprocessing business logic, which assists the formation of a clear GSO workflow structure. A workflow was implemented in the FAST pattern to simulate the flooding process in the Poyang Lake region. Experimental results show that the proposed FAST pattern can efficiently tackle data/computing intensive geoprocessing tasks. The performance of all collaborative partners was improved due to the asynchronous mechanism throughout communication tier. A status-tracking mechanism helps users retrieve the latest running status of a GSO workflow in an efficient and instant way. The clear structure of the GSO workflow lowers the barriers for geospatial domain experts and model designers to compose asynchronous GSO workflows. Most importantly, it provides better support for locating and diagnosing potential exceptions.
Telemedicine support shortens length of stay after fast-track hip replacement.
Vesterby, Martin Svoldgaard; Pedersen, Preben Ulrich; Laursen, Malene; Mikkelsen, Søren; Larsen, Jens; Søballe, Kjeld; Jørgensen, Lene Bastrup
2017-02-01
Background and purpose - Telemedicine could allow patients to be discharged more quickly after surgery and contribute to improve fast-track procedures without compromising quality, patient safety, functionality, anxiety, or other patient-perceived parameters. We investigated whether using telemedicine support (TMS) would permit hospital discharge after 1 day without loss of self-assessed quality of life, loss of functionality, increased anxiety, increased rates of re-admission, or increased rates of complications after hip replacement. Patients and methods - We performed a randomized controlled trial involving 72 Danish patients in 1 region who were referred for elective fast-track total hip replacement between August 2009 and March 2011 (654 were screened for eligibility). Half of the patients received a telemedicine solution connected to their TV. The patients were followed until 1 year after surgery. Results - Length of stay was reduced from 2.1 days (95% CI: 2.0-2.3) to 1.1 day (CI: 0.9-1.4; p < 0.001) with the TMS intervention. Health-related quality of life increased in both groups, but there were no statistically significant differences between groups. There were also no statistically significant differences between groups regarding timed up-and-go test and Oxford hip score at 3-month follow-up. At 12-month follow-up, the rates of complications and re-admissions were similar between the groups, but the number of postoperative hospital contacts was lower in the TMS group. Interpretation - Length of postoperative stay was shortened in patients with the TMS solution, without compromising patient-perceived or clinical parameters in patients undergoing elective fast-track surgery. These results indicate that telemedicine can be of value in fast-track treatment of patients undergoing total hip replacement.
Pedersen, Morten Høgild; Svart, Mads Vandsted; Lebeck, Janne; Bidlingmaier, Martin; Stødkilde-Jørgensen, Hans; Pedersen, Steen Bønløkke; Møller, Niels; Jessen, Niels; Jørgensen, Jens O L
2017-04-01
Insulin resistance and metabolic inflexibility are features of obesity and are amplified by fasting. Growth hormone (GH) secretion increases during fasting and GH causes insulin resistance. To study the metabolic effects of GH blockade during fasting in obese subjects. Nine obese males were studied thrice in a randomized design: (1) after an overnight fast (control), (2) after 72 hour fasting (fasting), and (3) after 72 hour fasting with GH blockade (pegvisomant) [fasting plus GH antagonist (GHA)]. Each study day consisted of a 4-hour basal period followed by a 2-hour hyperinsulinemic, euglycemic clamp combined with indirect calorimetry, assessment of glucose and palmitate turnover, and muscle and fat biopsies. GH levels increased with fasting (P < 0.01), and the fasting-induced reduction of serum insulin-like growth factor I was enhanced by GHA (P < 0.05). Fasting increased lipolysis and lipid oxidation independent of GHA, but fasting plus GHA caused a more pronounced suppression of lipid intermediates in response to hyperinsulinemic, euglycemic clamp. Fasting-induced insulin resistance was abrogated by GHA (P < 0.01) primarily due to reduced endogenous glucose production (P = 0.003). Fasting plus GHA also caused elevated glycerol levels and reduced levels of counterregulatory hormones. Fasting significantly reduced the expression of antilipolytic signals in adipose tissue independent of GHA. Suppression of GH activity during fasting in obese subjects reverses insulin resistance and amplifies insulin-stimulated suppression of lipid intermediates, indicating that GH is an important regulator of substrate metabolism, insulin sensitivity, and metabolic flexibility also in obese subjects. Copyright © 2017 by the Endocrine Society
Real-time tracking and fast retrieval of persons in multiple surveillance cameras of a shopping mall
NASA Astrophysics Data System (ADS)
Bouma, Henri; Baan, Jan; Landsmeer, Sander; Kruszynski, Chris; van Antwerpen, Gert; Dijk, Judith
2013-05-01
The capability to track individuals in CCTV cameras is important for e.g. surveillance applications at large areas such as train stations, airports and shopping centers. However, it is laborious to track and trace people over multiple cameras. In this paper, we present a system for real-time tracking and fast interactive retrieval of persons in video streams from multiple static surveillance cameras. This system is demonstrated in a shopping mall, where the cameras are positioned without overlapping fields-of-view and have different lighting conditions. The results show that the system allows an operator to find the origin or destination of a person more efficiently. The misses are reduced with 37%, which is a significant improvement.
Preventing Serious Conduct Problems in School-Age Youths: The Fast Track Program
Slough, Nancy M.; McMahon, Robert J.; Bierman, Karen L.; Coie, John D.; Dodge, Kenneth A.; Foster, E. Michael; Greenberg, Mark T.; Lochman, John E.; McMahon, Robert J.; Pinderhughes, Ellen E.
2009-01-01
Children with early-starting conduct Problems have a very poor prognosis and exact a high cost to society. The Fast Track project is a multisite, collaborative research project investigating the efficacy of a comprehensive, long-term, multicomponent intervention designed to prevent the development of serious conduct problems in high-risk children. In this article, we (a) provide an overview of the development model that serves as the conceptual foundation for the Fast Track intervention and describe its integration into the intervention model; (b) outline the research design and intervention model, with an emphasis on the elementary school phase of the intervention; and (c) summarize findings to dale concerning intervention outcomes. We then provide a case illustration, and conclude with a discussion of guidelines for practitioners who work with children with conduct problems. PMID:19890487
Research on Precision Tracking on Fast Steering Mirror and Control Strategy
NASA Astrophysics Data System (ADS)
Di, Lin; Yi-ming, Wu; Fan, Zhu
2018-01-01
Fast steering mirror is a device used for controlling the beam direction precisely. Due to the short travel of the push-pull FSM, a compound fast steering mirror system driven by both limited-angle voice coil motor and push-pull FSM together is proposed. In the compound FSM system, limited-angle voice coil motor quickly swings at wide angle, while the push-pull FSM do high frequency movement in a small range, which provides the system with the high bandwidth and long travel. In the control strategy, the method of combining feed-forward control in Kalman filtering with auto-disturbance rejection control is used to improve trajectory tracking accuracy. The simulation result shows that tracking accuracy measured by the compound method can be improved by more than 5 times than that of the conventional PID.
NASA Astrophysics Data System (ADS)
Lin, J.; Zhu, J.
2012-12-01
We present a new global model of oceanic crustal thickness based on inversion of global oceanic gravity anomaly with constrains from seismic crustal thickness profiles. We first removed from the observed marine free-air gravity anomaly all gravitational effects that can be estimated and removed using independent constraints, including the effects of seafloor topography, marine sediment thickness, and the age-dependent thermal structure of the oceanic lithosphere. We then calculated models of gravity-derived crustal thickness through inversion of the residual mantle Bouguer anomaly using best-fitting gravity-modeling parameters obtained from comparison with seismically determined crustal thickness profiles. Modeling results show that about 5% of the global crustal volume (or 9% of the global oceanic surface area) is associated with model crustal thickness <5.2 km (designated as "thin" crust), while 56% of the crustal volume (or 65% of the surface area) is associated with crustal thickness of 5.2-8.6 km thick (designated as "normal" crust). The remaining 39% of the crustal volume (or 26% of the surface area) is associated with crustal thickness >8.6 km and is interpreted to have been affected by excess magmatism. The percentage of oceanic crustal volume that is associated with thick crustal thickness (>8.6 km) varies greatly among tectonic plates: Pacific (33%), Africa (50%), Antarctic (33%), Australia (30%), South America (34%), Nazca (23%), North America (47%), India (74%), Eurasia (68%), Cocos (20%), Philippine (26%), Scotia (41%), Caribbean (89%), Arabian (82%), and Juan de Fuca (21%). We also found that distribution of thickened oceanic crust (>8.6 km) seems to depend on spreading rate and lithospheric age: (1) On ocean basins younger than 5 Ma, regions of thickened crust are predominantly associated with slow and ultraslow spreading ridges. The relatively strong lithospheric plate at slow and ultraslow ridges might facilitate the loading of large magmatic emplacements on the plate. (2) In contrast, crustal thickness near fast and intermediately fast spreading ridges typically does not exceed 7-8 km. The relatively weak lithosphere at fast and intermediately fast ridges might make it harder for excess magmatism to accrete. We further speculate that the relatively wide partial melting zones in the upper mantle beneath the fast and intermediately fast ridges might act as "buffer" zones, thus diluting the melt anomalies from the underlying hotspots or regions of mantle heterogeneities. (3) As the crustal age increases and the lithospheric plate thickens, regions of thickened crust start to develop on ocean basins that were originally created at fast and intermediately fast ridges. The integrated crustal volume for fast and intermediately fast ocean crust appears to reach peak values for certain geological periods, such as 40-50 Ma and 70-80 Ma. The newly constructed global models of gravity-derived crustal thickness, combining with geochemical and other constraints, can be used to investigate the processes of oceanic crustal accretion and hotspot-lithosphere interactions.
Sonic boom measurement test plan for Space Shuttle STS-3 reentry
NASA Technical Reports Server (NTRS)
Henderson, H. R.
1982-01-01
The lateral area from the reentry ground track affected by sonic boom overpressure levels is determined. Four data acquisition stations are deployed laterally to the STS-3 reentry flight track. These stations provide six intermediate band FM channels of sonic boom data, universal time synchronization, and voice annotation. All measurements are correlated with the vehicle reentry flight track information along with atmospheric and vehicle operation conditions.
ERIC Educational Resources Information Center
Blackett, Alexander David; Evans, Adam; Piggott, David
2017-01-01
At the beginning of the 2013/2014 season in England and Wales, 90 head coaches of the 92 men's national professional football league clubs and 20 of the 22 men's professional rugby union clubs had tenure as a professional elite player in their respective sports. Moreover, Rynne [(2014). "'Fast track' and 'traditional path' coaches:…
Perez-Martinez, Pablo; Corella, Dolores; Shen, Jian; Arnett, Donna K; Yiannakouris, Nikos; Tai, E Syong; Orho-Melander, Marju; Tucker, Katherine L; Tsai, Michael; Straka, Robert J; Province, Michael; Kai, Chew Suok; Perez-Jimenez, Francisco; Lai, Chao-Qiang; Lopez-Miranda, Jose; Guillen, Marisa; Parnell, Laurence D; Borecki, Ingrid; Kathiresan, Sekar; Ordovas, Jose M
2009-01-01
Hypertriglyceridemia is a risk factor for cardiovascular disease. Variation in the apolipoprotein A5 (APOA5) and glucokinase regulatory protein (GCKR) genes has been associated with fasting plasma triacylglycerol. We investigated the combined effects of the GCKR rs780094C-->T, APOA5 -1131T-->C, and APOA5 56C-->G single nucleotide polymorphisms (SNPs) on fasting triacylglycerol in several independent populations and the response to a high-fat meal and fenofibrate interventions. We used a cross-sectional design to investigate the association with fasting triacylglycerol in 8 populations from America, Asia, and Europe (n = 7,730 men and women) and 2 intervention studies in US whites (n = 1,061) to examine postprandial triacylglycerol after a high-fat meal and the response to fenofibrate. We defined 3 combined genotype groups: 1) protective (homozygous for the wild-type allele for all 3 SNPs); 2) intermediate (any mixed genotype not included in groups 1 and 3); and 3) risk (carriers of the variant alleles at both genes). Subjects within the risk group had significantly higher fasting triacylglycerol and a higher prevalence of hypertriglyceridemia than did subjects in the protective group across all populations. Moreover, subjects in the risk group had a greater postprandial triacylglycerol response to a high-fat meal and greater fenofibrate-induced reduction of fasting triacylglycerol than did the other groups, especially among persons with hypertriglyceridemia. Subjects with the intermediate genotype had intermediate values (P for trend <0.001). SNPs in GCKR and APOA5 have an additive effect on both fasting and postprandial triacylglycerol and contribute to the interindividual variability in response to fenofibrate treatment.
Perez-Martinez, Pablo; Corella, Dolores; Shen, Jian; Arnett, Donna K; Yiannakouris, Nikos; Tai, E Syong; Orho-Melander, Marju; Tucker, Katherine L; Tsai, Michael; Straka, Robert J; Province, Michael; Kai, Chew Suok; Perez-Jimenez, Francisco; Lai, Chao-Qiang; Lopez-Miranda, Jose; Guillen, Marisa; Parnell, Laurence D; Borecki, Ingrid; Kathiresan, Sekar; Ordovas, Jose M
2009-01-01
Background: Hypertriglyceridemia is a risk factor for cardiovascular disease. Variation in the apolipoprotein A5 (APOA5) and glucokinase regulatory protein (GCKR) genes has been associated with fasting plasma triacylglycerol. Objective: We investigated the combined effects of the GCKR rs780094C→T, APOA5 −1131T→C, and APOA5 56C→G single nucleotide polymorphisms (SNPs) on fasting triacylglycerol in several independent populations and the response to a high-fat meal and fenofibrate interventions. Design: We used a cross-sectional design to investigate the association with fasting triacylglycerol in 8 populations from America, Asia, and Europe (n = 7730 men and women) and 2 intervention studies in US whites (n = 1061) to examine postprandial triacylglycerol after a high-fat meal and the response to fenofibrate. We defined 3 combined genotype groups: 1) protective (homozygous for the wild-type allele for all 3 SNPs); 2) intermediate (any mixed genotype not included in groups 1 and 3); and 3) risk (carriers of the variant alleles at both genes). Results: Subjects within the risk group had significantly higher fasting triacylglycerol and a higher prevalence of hypertriglyceridemia than did subjects in the protective group across all populations. Moreover, subjects in the risk group had a greater postprandial triacylglycerol response to a high-fat meal and greater fenofibrate-induced reduction of fasting triacylglycerol than did the other groups, especially among persons with hypertriglyceridemia. Subjects with the intermediate genotype had intermediate values (P for trend <0.001). Conclusions: SNPs in GCKR and APOA5 have an additive effect on both fasting and postprandial triacylglycerol and contribute to the interindividual variability in response to fenofibrate treatment. PMID:19056598
Object tracking on mobile devices using binary descriptors
NASA Astrophysics Data System (ADS)
Savakis, Andreas; Quraishi, Mohammad Faiz; Minnehan, Breton
2015-03-01
With the growing ubiquity of mobile devices, advanced applications are relying on computer vision techniques to provide novel experiences for users. Currently, few tracking approaches take into consideration the resource constraints on mobile devices. Designing efficient tracking algorithms and optimizing performance for mobile devices can result in better and more efficient tracking for applications, such as augmented reality. In this paper, we use binary descriptors, including Fast Retina Keypoint (FREAK), Oriented FAST and Rotated BRIEF (ORB), Binary Robust Independent Features (BRIEF), and Binary Robust Invariant Scalable Keypoints (BRISK) to obtain real time tracking performance on mobile devices. We consider both Google's Android and Apple's iOS operating systems to implement our tracking approach. The Android implementation is done using Android's Native Development Kit (NDK), which gives the performance benefits of using native code as well as access to legacy libraries. The iOS implementation was created using both the native Objective-C and the C++ programing languages. We also introduce simplified versions of the BRIEF and BRISK descriptors that improve processing speed without compromising tracking accuracy.
How Does the Fast Track Intervention Prevent Adverse Outcomes in Young Adulthood?
Sorensen, Lucy C; Dodge, Kenneth A
2016-01-01
Numerous studies have shown that childhood interventions can foster improved outcomes in adulthood. Less well understood is precisely how-that is, through which developmental pathways-these interventions work. This study assesses mechanisms by which the Fast Track project (n = 891), a randomized intervention in the early 1990s for high-risk children in four communities (Durham, NC; Nashville, TN; rural PA; and Seattle, WA), reduced delinquency, arrests, and general and mental health service utilization in adolescence through young adulthood (ages 12-20). A decomposition of treatment effects indicates that about a third of Fast Track's impact on later crime outcomes can be accounted for by improvements in social and self-regulation skills during childhood (ages 6-11), such as prosocial behavior, emotion regulation, and problem solving. These skills proved less valuable for the prevention of general and mental health problems. © 2015 The Authors. Child Development © 2015 Society for Research in Child Development, Inc.
The new millennium program: Fast-track procurements
NASA Astrophysics Data System (ADS)
Metzger, Robert M.
1996-11-01
The National Aeronautics and Space Administration's (NASA's) New Millennium Program (NMP) has embarked on a technology flight-validation demonstration program to enable the kinds of missions that NASA envisions for the 21st century. Embedded in this program is the concept of rapid mission development supported by a fast-track procurement process. This process begins with the decision to initiate a procurement very early in the program along with the formation of a technical acquisition team. A close working relationship among the team members is essential to avoiding delays and developing a clear acquisition plan. The request for proposal (RFP) that is subsequently issued seeks a company with proven capabilities, so that the time allotted for responses from proposers and the length of proposals they submit can be shortened. The fast-track procurement process has been demonstrated during selection of NMP's industrial partners and has been proven to work.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsai, Han-Chung; Liu, Yung Y.; Lee, Hok L.
A system for monitoring a plurality radio frequency identification tags is described. The system uses at least one set of radio frequency identification tags. Each tag is attached to a container and includes several sensors for detecting physical conditions of said container. The system includes at least one autonomous intermediate reader in wireless communication with the frequency identification tags. The intermediate reader includes external wireless communication system, intermediate reader logic controller, and a self-contained rechargeable power supply. The system uses a central status reporting system in communication the intermediate reader.
Hemberger, Patrick; Custodis, Victoria B. F.; Bodi, Andras; Gerber, Thomas; van Bokhoven, Jeroen A.
2017-01-01
Catalytic fast pyrolysis is a promising way to convert lignin into fine chemicals and fuels, but current approaches lack selectivity and yield unsatisfactory conversion. Understanding the pyrolysis reaction mechanism at the molecular level may help to make this sustainable process more economic. Reactive intermediates are responsible for product branching and hold the key to unveiling these mechanisms, but are notoriously difficult to detect isomer-selectively. Here, we investigate the catalytic pyrolysis of guaiacol, a lignin model compound, using photoelectron photoion coincidence spectroscopy with synchrotron radiation, which allows for isomer-selective detection of reactive intermediates. In combination with ambient pressure pyrolysis, we identify fulvenone as the central reactive intermediate, generated by catalytic demethylation to catechol and subsequent dehydration. The fulvenone ketene is responsible for the phenol formation. This technique may open unique opportunities for isomer-resolved probing in catalysis, and holds the potential for achieving a mechanistic understanding of complex, real-life catalytic processes. PMID:28660882
NASA Technical Reports Server (NTRS)
Cheng, W.; Wen, J. T.
1992-01-01
A novel fast learning rule with fast weight identification is proposed for the two-time-scale neural controller, and a two-stage learning strategy is developed for the proposed neural controller. The results of the stability analysis show that both the tracking error and the fast weight error will be uniformly bounded and converge to a bounded region which depends only on the accuracy of the slow learning if the system is sufficiently excited. The efficiency of the two-stage learning is also demonstrated by a simulation of a two-link arm.
Docimo, A B; Pronovost, P J; Davis, R O; Concordia, E B; Gabrish, C M; Adessa, M S; Bessman, E
2000-09-01
In 1998 the emergency department (ED) Work Group at Johns Hopkins Bayview Medical Center (Baltimore) worked to reinvigorate the fast-track program within the ED to improve throughput for patients with minor illnesses and injuries who present for care. There had been two prior unsuccessful attempts to overhaul the fast-track process. The work group used a change model intended to improve both processes and relationships for complex organizational problems that span departments and functional units. Before the first work group meeting, the work group evaluated the institutional commitment to address the issue. The next step was to find data to fully understand the issues and establish a baseline for evaluating improvements--for example, patients with minor illnesses and injuries had excessively long total ED (registration to discharge) times: 5 hours 57 minutes on average for nonacute patients. ONLINE AND OFFLINE MEETINGS: The work group identified process problems, but relationship barriers became evident as the new processes were discussed. Yet offline work was needed to minimize the potential for online surprises. The work group leaders met separately in small groups with nursing staff, lab staff, x-ray staff, registrars, and physician's assistants to inform them of data, obtain input about process changes, and address any potential concerns. The group conducted four tests of change (using Plan-Do-Study-Act cycles) to eliminate the root causes of slow turnaround identified previously. Total ED time decreased to an average of 1 hour 47 minutes; the practice of placing nonacute patients in fast track before all higher-acuity patients were seen gained acceptance. The percentage of higher-acuity patients sent to fast track decreased from 17% of all patients seen in fast track in January 1998 to 8.5% by February 1999. Patients with minor illnesses and injuries no longer had to wait behind higher-acuity patients just to be registered. The average wait for registration decreased from 42 minutes in January 1998 to 14 minutes in February 1999. Physician's assistant, nursing, and technician staff all report improved working relationships and feeling a team spirit. The offline component of the integrated model helped to improve organizational relationships and dialogue among team members, thereby facilitating the effectiveness of online efforts to improve processes. This model has also been applied to improve patient registration (revenue recovery) and the emergency transfer and admissions process.
1997-03-01
found in several different terms: Deep selection, early promotion or fast-track promotion. The latter is common lingo of labor economics . Throughout...this thesis the military terms will be used interchangeably, "fast-track promotion" will be used as term in a labor economics context. because they put...found that FITREP 5 Holt: Managerial Principles & Practices, Ehrenberg/Smith: Modern Labor Economics , WEST Series of Organizational Behaviour, as a few
Navigator GPS Receiver for Fast Acquisition and Weak Signal Space Applications
NASA Technical Reports Server (NTRS)
Winternitz, Luke; Moreau, Michael; Boegner, Gregory J.; Sirotzky, Steve
2004-01-01
NASA Goddard Space Flight Center (GSFC) is developing a new space-borne GPS receiver that can operate effectively in the full range of Earth orbiting missions from Low Earth Orbit (LEO) to geostationary and beyond. Navigator is designed to be a fully space flight qualified GPS receiver optimized for fast signal acquisition and weak signal tracking. The fast acquisition capabilities provide exceptional time to first fix performance (TIFF) with no a priori receiver state or GPS almanac information, even in the presence of high Doppler shifts present in LEO (or near perigee in highly eccentric orbits). The fast acquisition capability also makes it feasible to implement extended correlation intervals and therefore significantly reduce Navigator s acquisition threshold. This greatly improves GPS observability when the receiver is above the GPS constellation (and satellites must be tracked from the opposite side of the Earth) by providing at least 10 dB of increased acquisition sensitivity. Fast acquisition and weak signal tracking algorithms have been implemented and validated on a hardware development board. A fully functional version of the receiver, employing most of the flight parts, with integrated navigation software is expected by mid 2005. An ultimate goal of this project is to license the Navigator design to an industry partner who will then market the receiver as a commercial product.
NASA Technical Reports Server (NTRS)
White, P. R.; Scott, D. R. (Inventor)
1981-01-01
A solar tracker for a solar collector is described in detail. The collector is angularly oriented by a motor wherein the outputs of two side-by-side photodetectors are discriminated as to three ranges: a first corresponding to a low light or darkness condition; a second corresponding to light intensity lying in an intermediate range; and a third corresponding to light above an intermediate range, direct sunlight. The first output drives the motor to a selected maximum easterly angular position; the second enables the motor to be driven westerly at the Earth rotational rate; and the third output, the separate outputs of the two photodetectors, differentially controls the direction of rotation of the motor to effect actual tracking of the Sun.
The Compressed Baryonic Matter experiment at FAIR
NASA Astrophysics Data System (ADS)
Höhne, Claudia
2018-02-01
The CBM experiment will investigate highly compressed baryonic matter created in A+A collisions at the new FAIR research center. With a beam energy range up to 11 AGeV for the heaviest nuclei at the SIS 100 accelerator, CBM will investigate the QCD phase diagram in the intermediate range, i.e. at moderate temperatures but high net-baryon densities. This intermediate range of the QCD phase diagram is of particular interest, because a first order phase transition ending in a critical point and possibly new highdensity phases of strongly interacting matter are expected. In this range of the QCD phase diagram only exploratory measurements have been performed so far. CBM, as a next generation, high-luminosity experiment, will substantially improve our knowledge of matter created in this region of the QCD phase diagram and characterize its properties by measuring rare probes such as multi-strange hyperons, dileptons or charm, but also with event-by-event fluctuations of conserved quantities, and collective flow of identified particles. The experimental preparations with special focus on hadronic observables and strangeness is presented in terms of detector development, feasibility studies and fast track reconstruction. Preparations are progressing well such that CBM will be ready with FAIR start. As quite some detectors are ready before, they will be used as upgrades or extensions of already running experiments allowing for a rich physics program prior to FAIR start.
Intermediate Palomar Transient Factory: Realtime Image Subtraction Pipeline
Cao, Yi; Nugent, Peter E.; Kasliwal, Mansi M.
2016-09-28
A fast-turnaround pipeline for realtime data reduction plays an essential role in discovering and permitting followup observations to young supernovae and fast-evolving transients in modern time-domain surveys. In this paper, we present the realtime image subtraction pipeline in the intermediate Palomar Transient Factory. By using highperformance computing, efficient databases, and machine-learning algorithms, this pipeline manages to reliably deliver transient candidates within 10 minutes of images being taken. Our experience in using high-performance computing resources to process big data in astronomy serves as a trailblazer to dealing with data from large-scale time-domain facilities in the near future.
Intermediate Palomar Transient Factory: Realtime Image Subtraction Pipeline
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cao, Yi; Nugent, Peter E.; Kasliwal, Mansi M.
A fast-turnaround pipeline for realtime data reduction plays an essential role in discovering and permitting followup observations to young supernovae and fast-evolving transients in modern time-domain surveys. In this paper, we present the realtime image subtraction pipeline in the intermediate Palomar Transient Factory. By using highperformance computing, efficient databases, and machine-learning algorithms, this pipeline manages to reliably deliver transient candidates within 10 minutes of images being taken. Our experience in using high-performance computing resources to process big data in astronomy serves as a trailblazer to dealing with data from large-scale time-domain facilities in the near future.
Fast-track eligibility of geriatric patients undergoing short urologic surgery procedures.
Fredman, Brian; Sheffer, Offer; Zohar, Edna; Paruta, Irena; Richter, Santiago; Jedeikin, Robert; White, Paul F
2002-03-01
Our primary objective was to assess the feasibility of geriatric patients (>65 yr) bypassing the postanesthesia care unit (PACU) after ambulatory surgery. A secondary objective was to compare recovery profiles when using three different maintenance anesthetics. Ninety ASA physical status I--III consenting outpatients (>65 yr) undergoing short urologic procedures were randomly assigned to one of three anesthetic treatment groups. After a standardized induction with fentanyl and propofol, anesthesia was maintained with propofol (75-150 microg center dot kg(-1) center dot min(-1) IV), isoflurane (0.7%-1.2% end tidal), or desflurane (3%-6% end tidal), in combination with nitrous oxide 70% in oxygen. In all three groups, the primary anesthetic was titrated to maintain an electroencephalographic-bispectral index value of 60-65. Recovery times, postanesthesia recovery scores, and therapeutic interventions in the PACU were recorded. Although emergence times were similar in the three groups, the time to achieve a fast-track discharge score of 14 was significantly shorter in patients receiving desflurane compared with propofol and isoflurane (22 +/- 23 vs 33 +/- 25 and 44 +/- 36 min, respectively). On arrival in the PACU, a significantly larger percentage of patients receiving desflurane were judged to be fast-track eligible compared with those receiving either isoflurane and propofol (73% vs 43% and 44%, respectively). The number of therapeutic interventions in the PACU was also significantly larger in the Isoflurane group when compared with the Propofol and Desflurane groups (21 vs 11 and 7, respectively). In conclusion, use of desflurane for maintenance of anesthesia should facilitate PACU bypass ("fast-tracking") of geriatric patients undergoing short urologic procedures. Geriatric outpatients undergoing brief urologic procedures more rapidly achieve fast-tracking discharge criteria after desflurane (versus isoflurane and propofol) anesthesia. Use of isoflurane was also associated with an increased need for nursing interventions in the early recovery period compared with desflurane and propofol.
A novel approach to Hough Transform for implementation in fast triggers
NASA Astrophysics Data System (ADS)
Pozzobon, Nicola; Montecassiano, Fabio; Zotto, Pierluigi
2016-10-01
Telescopes of position sensitive detectors are common layouts in charged particles tracking, and programmable logic devices, such as FPGAs, represent a viable choice for the real-time reconstruction of track segments in such detector arrays. A compact implementation of the Hough Transform for fast triggers in High Energy Physics, exploiting a parameter reduction method, is proposed, targeting the reduction of the needed storage or computing resources in current, or next future, state-of-the-art FPGA devices, while retaining high resolution over a wide range of track parameters. The proposed approach is compared to a Standard Hough Transform with particular emphasis on their application to muon detectors. In both cases, an original readout implementation is modeled.
77 FR 28193 - Excepted Service, Career and Career-Conditional Employment; and Pathways Programs
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-11
... advancement opportunities to Pathways Participants who are ``fast-tracked'' into desirable positions. The union's concern is misplaced. As an initial matter, the Pathways Participants are not being ``fast...-the-job experience that they otherwise would not be able to obtain. Indeed, rather than being ``fast...
1989-09-16
SWOTHR was conceived to be an organic asset capable of providing early detection and tracking of fast , surface-skimming threats, such as cruise missiles...distributed real-time processing and threat tracking system. Spe- cific project goals were to verify detection performance pree ctions for small, fast targets...means that enlarging the ground plane would have been a fruitless excercise in any event. B-6 5 i I U Table B-1 summarizes the calculated parameters of
Detlefsen, Ellen G
2004-01-01
The article describes an innovation in MLIS education for medical librarianship, with an introduction to the FastTrack, the distance education program at the University of Pittsburgh's library and information science school, together with an overview of a model program linking the biomedical library at Vanderbilt University with the School of Information Sciences in Pittsburgh. Admissions requirements and specific curriculum for the distance education master's degree are detailed in an FAQ format.
Studies on fast triggering and high precision tracking with Resistive Plate Chambers
NASA Astrophysics Data System (ADS)
Aielli, G.; Ball, R.; Bilki, B.; Chapman, J. W.; Cardarelli, R.; Dai, T.; Diehl, E.; Dubbert, J.; Ferretti, C.; Feng, H.; Francis, K.; Guan, L.; Han, L.; Hou, S.; Levin, D.; Li, B.; Liu, L.; Paolozzi, L.; Repond, J.; Roloff, J.; Santonico, R.; Song, H. Y.; Wang, X. L.; Wu, Y.; Xia, L.; Xu, L.; Zhao, T.; Zhao, Z.; Zhou, B.; Zhu, J.
2013-06-01
We report on studies of fast triggering and high precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV/c muon beam at CERN using glass RPCs with gas gaps of 1.15 mm and equipped with readout strips with 1.27 mm pitch. This is the first beam test of RPCs with fine-pitch readout strips that explores precision tracking and triggering capabilities. RPC signals were acquired with precision timing and charge integrating readout electronics at both ends of the strips. The time resolution was measured to be better than 600 ps and the average spatial resolution was found to be 220 μm using charge information and 287 μm only using signal arrival time information. The dual-ended readout allows the determination of the average and the difference of the signal arrival times. The average time was found to be independent of the incident particle position along the strip and is useful for triggering purposes. The time difference yielded a determination of the hit position with a precision of 7.5 mm along the strip. These results demonstrate the feasibility using RPCs for fast and high-resolution triggering and tracking.
Measuring Sound Speed in Gas Mixtures Using a Photoacoustic Generator
NASA Astrophysics Data System (ADS)
Suchenek, Mariusz; Borowski, Tomasz
2018-01-01
We present a new method which allows us to percentage distinction of gas composition with a fast response time. This system uses the speed of sound in a resonant cell along with temperature to determine the gas mixture composition. The gas mixtures contain two gases with an unknown combination. In our experiment, the acoustic waves were excited inside the acoustic longitudinal resonator with the use of a positive feedback. This feedback provides fast tracking of a resonance frequency of the cell and causes fast tracking changes in the speed of sound. The presented method corresponds to the theoretical description of this topic. Two gas mixtures—carbon dioxide and argon mixed with nitrogen—were tested.
A-Track: Detecting Moving Objects in FITS images
NASA Astrophysics Data System (ADS)
Atay, T.; Kaplan, M.; Kilic, Y.; Karapinar, N.
2017-04-01
A-Track is a fast, open-source, cross-platform pipeline for detecting moving objects (asteroids and comets) in sequential telescope images in FITS format. The moving objects are detected using a modified line detection algorithm.
ERIC Educational Resources Information Center
Suda, Chikako; Call, Josep
2006-01-01
The study investigates what an intermediate success rate means in bonobos, chimpanzees, and orangutans. Apes participated in liquid conservation experiments where they had to track the larger of two different quantities of juice after various kinds of transformations [Suda, C., & Call, J. (2004). Piagetian liquid conservation in the great apes…
Paglieroni, David W [Pleasanton, CA; Manay, Siddharth [Livermore, CA
2011-12-20
A stochastic method and system for detecting polygon structures in images, by detecting a set of best matching corners of predetermined acuteness .alpha. of a polygon model from a set of similarity scores based on GDM features of corners, and tracking polygon boundaries as particle tracks using a sequential Monte Carlo approach. The tracking involves initializing polygon boundary tracking by selecting pairs of corners from the set of best matching corners to define a first side of a corresponding polygon boundary; tracking all intermediate sides of the polygon boundaries using a particle filter, and terminating polygon boundary tracking by determining the last side of the tracked polygon boundaries to close the polygon boundaries. The particle tracks are then blended to determine polygon matches, which may be made available, such as to a user, for ranking and inspection.
Carré, Justin M; Iselin, Anne-Marie R; Welker, Keith M; Hariri, Ahmad R; Dodge, Kenneth A
2014-05-01
We tested the hypotheses that the Fast Track intervention program for high-risk children would reduce adult aggressive behavior and that this effect would be mediated by decreased testosterone responses to social provocation. Participants were a subsample of males from the full trial sample, who during kindergarten had been randomly assigned to the 10-year Fast Track intervention or to a control group. The Fast Track program attempted to develop children's social competencies through child social-cognitive and emotional-coping skills training, peer-relations coaching, academic tutoring, and classroom management, as well as training for parents to manage their child's behavior. At a mean age of 26 years, participants responded to laboratory provocations. Results indicated that, relative to control participants, men assigned to the intervention demonstrated reduced aggression and testosterone reactivity to social provocations. Moreover, reduced testosterone reactivity mediated the effect of intervention on aggressive behavior, which provides evidence for an enduring biological mechanism underlying the effect of early psychosocial intervention on aggressive behavior in adulthood.
Sethupathi, M; Blackwell, A
2009-03-01
We introduced a Nurse/Health Advisor-led fast-track service for treating patients diagnosed with chlamydia outside a genitourinary medicine setting and contacts of chlamydia/non-specific urethritis/cervicitis wherever diagnosed. Asymptomatic patients were treated without initial testing and asked to return for full screening at four to six weeks. We assessed the efficacy and safety of the system and need for follow-up after treatment. Case-notes of 226 patients (121 men and 105 women) were analysed, of whom 140 attended follow-up. With the exception of one case of gonorrhoea, no other serious sexually transmitted infection was detected. Twenty-seven (19.2%) patients were re-treated for either chlamydia (six patients, 4.4%) or non-specific genital infection or because of having unprotected intercourse with untreated or partially treated partners. We conclude that in our relatively low-risk population, our fast-track service is safe and effective. Test of cure for chlamydia seems essential because of the high percentage of patients requiring re-treatment.
Real-Time Robust Tracking for Motion Blur and Fast Motion via Correlation Filters.
Xu, Lingyun; Luo, Haibo; Hui, Bin; Chang, Zheng
2016-09-07
Visual tracking has extensive applications in intelligent monitoring and guidance systems. Among state-of-the-art tracking algorithms, Correlation Filter methods perform favorably in robustness, accuracy and speed. However, it also has shortcomings when dealing with pervasive target scale variation, motion blur and fast motion. In this paper we proposed a new real-time robust scheme based on Kernelized Correlation Filter (KCF) to significantly improve performance on motion blur and fast motion. By fusing KCF and STC trackers, our algorithm also solve the estimation of scale variation in many scenarios. We theoretically analyze the problem for CFs towards motions and utilize the point sharpness function of the target patch to evaluate the motion state of target. Then we set up an efficient scheme to handle the motion and scale variation without much time consuming. Our algorithm preserves the properties of KCF besides the ability to handle special scenarios. In the end extensive experimental results on benchmark of VOT datasets show our algorithm performs advantageously competed with the top-rank trackers.
Flying Qualities Design Requirements for Sidestick Controllers
1979-10-01
Harper vs wc - Fine Tracking 111 56. Cooper-Harper vs wc - Fine Tracking 111 57. Cooper-Harper ve wc - Landing 112 58. Cooper-Harper vs wc - Lending 112...c - Fine Tracking 119 62. Preference Rating vs wc - Fine Tracking 119 64. Preference Rating vs wc - Landing 120 65. Preference Rating vs w(c...a "fast airplane" to make up for the filtering effect of his arm and the stick. In fine tracking with a center stick the pilot will rest his arm
A sun-tracking environmental chamber for the outdoor quantification of CPV modules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faiman, David, E-mail: faiman@bgu.ac.il; Melnichak, Vladimir, E-mail: faiman@bgu.ac.il; Bokobza, Dov, E-mail: faiman@bgu.ac.il
2014-09-26
The paper describes a sun-tracking environmental chamber and its associated fast electronics, devised for the accurate outdoor characterization of CPV cells, receivers, mono-modules, and modules. Some typical measurement results are presented.
Prades, J; Espinàs, J A; Font, R; Argimon, J M; Borràs, J M
2011-01-01
Background: The Cancer Fast-track Programme's aim was to reduce the time that elapsed between well-founded suspicion of breast, colorectal and lung cancer and the start of initial treatment in Catalonia (Spain). We sought to analyse its implementation and overall effectiveness. Methods: A quantitative analysis of the programme was performed using data generated by the hospitals on the basis of seven fast-track monitoring indicators for the period 2006–2009. In addition, we conducted a qualitative study, based on 83 semistructured interviews with primary and specialised health professionals and health administrators, to obtain their perception of the programme's implementation. Results: About half of all new patients with breast, lung or colorectal cancer were diagnosed via the fast track, though the cancer detection rate declined across the period. Mean time from detection of suspected cancer in primary care to start of initial treatment was 32 days for breast, 30 for colorectal and 37 for lung cancer (2009). Professionals associated with the implementation of the programme showed that general practitioners faced with suspicion of cancer had changed their conduct with the aim of preventing lags. Furthermore, hospitals were found to have pursued three specific implementation strategies (top-down, consensus-based and participatory), which made for the cohesion and sustainability of the circuits. Conclusion: The programme has contributed to speeding up diagnostic assessment and treatment of patients with suspicion of cancer, and to clarifying the patient pathway between primary and specialised care. PMID:21829194
Gastinger, Ingo; Meyer, Frank; Lembcke, Thomas; Schmidt, Uwe; Ptok, Henry; Lippert, Hans
2012-08-01
The aim of the study was to determine statistically significant factors with an impact on the early postoperative surgical outcome. The influence of applied fast-track components on surgical results and early postoperative outcome in 143 consecutive Kausch-Whipple procedure patients was evaluated in a single-center retrospective analysis of a prospective collection of patient-associated pre-, peri- and postoperative data from 1997-2006. The in-hospital mortality rate was 2.8% (n=4). Fast-track measures were shown to have no effect on the morbidity rate in the multi-variate analysis. Over the study period, a decrease of intraoperative infusion volume from 14.2 mL/kg body weight/h in the first year to 10.7 mL/kg body weight/h in the last year was accompanied by an increase in patients requiring intraoperative catecholamines, up from 17% to 95%. The administration of ropivacain/sufentanil via thoracic peri-dural catheter injection initiated in 2000 and now considered the leading analgesic method, was used in 95% of the cases in 2006. Early extubation rate rose from 16.6% to 57.9%. Fast-track aspects in the perioperative management have become more important in several surgical procedure even in those with a greater invasiveness such as Kausch-Whipple. However, such techniques used in peri-operative management of Kausch-Whipple pancreatic-head resections had no impact on the morbidity rate. In addition, the low in-hospital mortality rate was particularly attributed to surgical competence.
Tokuda, Osamu; Harada, Yuko; Ueda, Takaaki; Iida, Etsushi; Shiraishi, Gen; Motomura, Tetsuhisa; Fukuda, Kouji; Matsunaga, Naofumi
2012-11-01
We compared intermediate-weighted fast spin-echo (IW-FSE) images with intermediate-weighted fast-recovery FSE (IW-FRFSE) images in the diagnosis of meniscal tears. First, 64 patients were recruited, and the arthroscopic findings (n = 40) and image analysis (n = 19) identified 59 torn menisci with 36 patients. Both the diagnostic performance and image quality in assessing meniscal tears was evaluated for IW-FSE and IW-FRFSE images using a four-point scale. Signal-to-noise ratio (SNR) calculation was performed for both sets of images. IW-FRFSE image specificity (100 %) for diagnosing the posterior horn of the medial meniscus (MM) tear with reader 1 was significantly higher than that of IW-FSE images (90 %). Mean ratings of the contrast between the lesion and normal signal intensity within the meniscus were significantly higher for the IW-FRFSE image ratings than the IW-FSE images in most meniscal tears. Mean SNRs were significantly higher for IW-FSE images than for IW-FRFSE images (P < 0.05). IW-FRFSE imaging can be used as an alternative to the IW-FSE imaging to evaluate meniscal tears.
Saracini, Claudio; Ohkubo, Kei; Suenobu, Tomoyoshi; Meyer, Gerald J; Karlin, Kenneth D; Fukuzumi, Shunichi
2015-12-23
Photoexcitation of end-on trans-μ-1,2-peroxodicopper(II) complex [(tmpa)2Cu(II)2(O2)](2+) (1) (λmax = 525 and 600 nm) and side-on μ-η(2):η(2)-peroxodicopper(II) complexes [(N5)Cu(II)2(O2)](2+) (2) and [(N3)Cu(II)2(O2)](2+) (3) at -80 °C in acetone led to one-photon two-electron peroxide-to-dioxygen oxidation chemistry (O2(2-) + hν → O2 + 2e(-)). Interestingly, light excitation of 2 and 3 (having side-on μ-η(2):η(2)-peroxo ligation) led to release of dioxygen, while photoexcitation of 1 (having an end-on trans-1,2-peroxo geometry) did not, even though spectroscopic studies revealed that both reactions proceeded through previously unknown mixed-valent superoxide species: [Cu(II)(O2(•-))Cu(I)](2+) (λmax = 685-740 nm). For 1, this intermediate underwent further fast intramolecular electron transfer to yield an "O2-caged" dicopper(I) adduct, Cu(I)2-O2, and a barrierless stepwise back electron transfer to regenerate 1 occurred. Femtosecond laser excitation of 2 and 3 under the same conditions still led to [Cu(II)(O2(•-))Cu(I)](2+) intermediates that, instead, underwent O2 release with a quantum yield of 0.14 ± 0.1 for 3. Such remarkable differences in reaction pathways likely result from the well-known ligand-derived stability of 2 and 3 vs 1 indicated by ligand-Cu(II/I) redox potentials; (N5)Cu(I) and (N3)Cu(I) complexes are far more stable than (tmpa)Cu(I) species. The fast Cu(I)2/O2 rebinding kinetics was also measured after photoexcitation of 2 and 3, with the results closely tracking those known for the dicopper proteins hemocyanin and tyrosinase, for which the synthetic dicopper(I) precursors [(N5)Cu(I)2](2+) and [(N3)Cu(I)2](2+) and their dioxygen adducts serve as models. The biological relevance of the present findings is discussed, including the potential impact on the solar water splitting process.
Three-dimensional particle tracking velocimetry using dynamic vision sensors
NASA Astrophysics Data System (ADS)
Borer, D.; Delbruck, T.; Rösgen, T.
2017-12-01
A fast-flow visualization method is presented based on tracking neutrally buoyant soap bubbles with a set of neuromorphic cameras. The "dynamic vision sensors" register only the changes in brightness with very low latency, capturing fast processes at a low data rate. The data consist of a stream of asynchronous events, each encoding the corresponding pixel position, the time instant of the event and the sign of the change in logarithmic intensity. The work uses three such synchronized cameras to perform 3D particle tracking in a medium sized wind tunnel. The data analysis relies on Kalman filters to associate the asynchronous events with individual tracers and to reconstruct the three-dimensional path and velocity based on calibrated sensor information.
[Morbidity and hospital cost reduction in cardiac surgery using a presurgery ambulatory strategy].
Ávila-Vanzzini, Nydia; Kuri-Alfaro, Jorge; Rodríguez-Chávez, Laura Leticia; Meléndez-Ramírez, Gabriela; Trevethan-Cravioto, Sergio; Quiroz-Martínez, Alejandro; Herrera-Bello, Héctor; Herrera-Alarcón, Valentín; Martínez-Hernández, Humberto; Martínez-Ríos, Marco Antonio
2010-01-01
In our hospital, the patients that need an elective cardiac surgery are admitted through the admission department on the basis of a waiting list. Since 1999, a fast track to hospitalization program has existed in the National Institute of Cardiology Ignacio Chavez for patients with low surgical risk. Later, in 2004, this program was extended to patients to moderate risk, based on rules accepted worldwide, and our own experience. 1) To compare two ways of admission that are used currently: fast track to hospitalization, against admission department waiting list. We compared major events: death or events that increased the hospital stay by more than 14 days (infections, alterations of rhythm and conduction, reoperations and others), 2) To compare the days of hospitalization and money spent by the hospital. We conformed 2 groups of 347 patients. The admission department waiting list group was admitted before doing their preoperative studies, which is the customary form for hospitalization by our admissions department, while the group of fast track to hospitalization was obligated to have their laboratory exams complete and any other diseases resolved or controlled previously. The monetary cost per patient for the hospital was calculated based on the patient's socioeconomic classification. Student t test was conduncted on independent samples and numerical variables, and Chi square for categorical variables. We considered a p <0.05 to be statistically significant. In average in both groups, 75% underwent valve operation and 25% underwent congenital heart disease repair, 49% were women, age 47 15 years. The comparison between the groups fast track to hospitalization and admission department waiting list group were: Mortality: 4.3% vs. 5.8% (p=0.38). Major events that needed a hospital stay of more than 14 days: 73 vs. 97 cases respectively (p = 0.032). Infections: 22 vs. 29 (p = 0.14). Mediastinitis: 2 vs. 9 respectively (p = 0.033). In-hospital stay: were 11 days vs. 20 days (p = 0.0001), the biggest difference was found in the pre-surgical time: 2 vs. 9 days respectively (p = 0.0001). The postoperative morbidity in general was lower in fast track to hospitalization group, and the mediastinitis showed a decrease with statistical significance. The time interval between hospital admission an operation in fast track to hospitalization group was significantly shorter. We believe that the decrease in the exposure time to nosocomial pathogens present in the hospital environment was directly related to the low number of mediastinitis. Finally, the decrease in time of hospital stay represented a 32% monetary savings for the hospital.
NASA Astrophysics Data System (ADS)
Yen, J.; Pender Healy, L. A.; Heaphy, M.
2016-02-01
Flow sensing by the mechanoreceptive cuticular arrays of sensors on copepods has been shaped by over 400 million years of evolution and plays an important role in predator avoidance, foraging, mating, and rheotaxis. These 3D wakes are produced by animal propulsive activities and contain cues that guide these key survival responses. We have demonstrated that the fluid mechanical and chemical information retained in the hydrodynamic envelope can be interpreted by suitable sensor arrays; copepod sensor arrays are capable of perceiving minute differences in wake structures. Temora longicornis, a coastal marine copepod, and Hesperodiaptomus shoshone, a high-alpine freshwater lake copepod, track laminar trails. High-speed videography coupled with high-magnification Schlieren optics enabled us to visualize the deformation of the trail signal and the propulsive movements of the male copepod. Males followed the trail mimic and our observations show clear differences between the marine and freshwater species. Comparative analyses reveal tracking mechanisms that differ in sensor location with respect to the trail and locomotory kinematics. Copepods perform directed motions that lead them to a stimulus source in the absence of other collimating stimuli. Tracking by the copepod around the trail allows it to have one or numerous sensors inside and outside the trail to facilitate edge detection using spatial sampling. The advantage of this remarkable behavior of following trails fast and accurately is to encounter mates or food patches more frequently, thus contributing to population recruitment and energy transfer up the trophic food web. Precise mate and food finding strategies found for pelagic copepods may be a key adaptation, promoting survival in these open-ocean planktonic populations.
Brewer, LaPrincess C; Redmond, Nicole; Slusser, Joshua P; Scott, Christopher G; Chamberlain, Alanna M; Djousse, Luc; Patten, Christi A; Roger, Veronique L; Sims, Mario
2018-06-05
Ideal cardiovascular health metrics (defined by the American Heart Association Life's Simple 7 [LS7]) are suboptimal among blacks, which results in high risk of cardiovascular disease. We examined the association of multiple stressors with LS7 components among blacks. Using a community-based cohort of blacks (N=4383), we examined associations of chronic stress, minor stressors, major life events, and a cumulative stress score with LS7 components (smoking, diet, physical activity, body mass index, blood pressure, total cholesterol, and fasting plasma glucose) and an LS7 composite score. Multivariable logistic regression assessed the odds of achieving intermediate/ideal levels of cardiovascular health adjusted for demographic, socioeconomic, behavioral, and biomedical factors. The LS7 components with the lowest percentages of intermediate/ideal cardiovascular health levels were diet (39%), body mass index (47%), and physical activity (51%). Higher chronic, minor, and cumulative stress scores were associated with decreased odds (odds ratio [OR]) of achieving intermediate/ideal levels for smoking (OR [95% confidence interval], 0.80 [0.73-0.88], 0.84 [0.75-0.94], and 0.81 [0.74-0.90], respectively). Participants with more major life events had decreased odds of achieving intermediate/ideal levels for smoking (OR, 0.84; 95% confidence interval, 0.76-0.92) and fasting plasma glucose (OR, 0.90; 95% confidence interval, 0.82-0.98). Those with higher scores for minor stressors and major life events were less likely to achieve intermediate or ideal LS7 composite scores (OR [95% confidence interval], 0.89 [0.81-0.97] and 0.91 [0.84-0.98], respectively). Blacks with higher levels of multiple stress measures are less likely to achieve intermediate or ideal levels of overall cardiovascular health (LS7 composite score), specific behaviors (smoking), and biological factors (fasting plasma glucose). © 2018 The Authors and Mayo Clinic. Published on behalf of the American Heart Association, Inc., by Wiley.
Malinowski, K; Skladnik-Sadowska, E; Sadowski, M J; Szydlowski, A; Czaus, K; Kwiatkowski, R; Zaloga, D; Paduch, M; Zielinska, E
2015-01-01
The paper concerns fast protons and neutrons from D-D fusion reactions in a Plasma-Focus-1000U facility. Measurements were performed with nuclear-track detectors arranged in "sandwiches" of an Al-foil and two PM-355 detectors separated by a polyethylene-plate. The Al-foil eliminated all primary deuterons, but was penetrable for fast fusion protons. The foil and first PM-355 detector were penetrable for fast neutrons, which were converted into recoil-protons in the polyethylene and recorded in the second PM-355 detector. The "sandwiches" were irradiated by discharges of comparable neutron-yields. Analyses of etched tracks and computer simulations of the fusion-products behavior in the detectors were performed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malinowski, K., E-mail: karol.malinowski@ncbj.gov.pl; Sadowski, M. J.; Szydlowski, A.
2015-01-15
The paper concerns fast protons and neutrons from D-D fusion reactions in a Plasma-Focus-1000U facility. Measurements were performed with nuclear-track detectors arranged in “sandwiches” of an Al-foil and two PM-355 detectors separated by a polyethylene-plate. The Al-foil eliminated all primary deuterons, but was penetrable for fast fusion protons. The foil and first PM-355 detector were penetrable for fast neutrons, which were converted into recoil-protons in the polyethylene and recorded in the second PM-355 detector. The “sandwiches” were irradiated by discharges of comparable neutron-yields. Analyses of etched tracks and computer simulations of the fusion-products behavior in the detectors were performed.
An Intermediate in the evolution of superfast sonic muscles
2011-01-01
Background Intermediate forms in the evolution of new adaptations such as transitions from water to land and the evolution of flight are often poorly understood. Similarly, the evolution of superfast sonic muscles in fishes, often considered the fastest muscles in vertebrates, has been a mystery because slow bladder movement does not generate sound. Slow muscles that stretch the swimbladder and then produce sound during recoil have recently been discovered in ophidiiform fishes. Here we describe the disturbance call (produced when fish are held) and sonic mechanism in an unrelated perciform pearl perch (Glaucosomatidae) that represents an intermediate condition in the evolution of super-fast sonic muscles. Results The pearl perch disturbance call is a two-part sound produced by a fast sonic muscle that rapidly stretches the bladder and an antagonistic tendon-smooth muscle combination (part 1) causing the tendon and bladder to snap back (part 2) generating a higher-frequency and greater-amplitude pulse. The smooth muscle is confirmed by electron microscopy and protein analysis. To our knowledge smooth muscle attachment to a tendon is unknown in animals. Conclusion The pearl perch, an advanced perciform teleost unrelated to ophidiiform fishes, uses a slow type mechanism to produce the major portion of the sound pulse during recoil, but the swimbladder is stretched by a fast muscle. Similarities between the two unrelated lineages, suggest independent and convergent evolution of sonic muscles and indicate intermediate forms in the evolution of superfast muscles. PMID:22126599
The Flex Track: Flexible Partitioning between Low- and High-Acuity Areas of an Emergency Department
Laker, Lauren F.; Froehle, Craig M.; Lindsell, Christopher J.; Ward, Michael J.
2014-01-01
Study Objective EDs with both low- and high-acuity treatment areas often have fixed allocation of resources, regardless of demand. We demonstrate the utility of discrete-event simulation to evaluate flexible partitioning between low- and high-acuity ED areas to identify the best operational strategy for subsequent implementation. Methods A discrete-event simulation was used to model patient flow through a 50-bed, urban, teaching ED that handles 85,000 patient visits annually. The ED has historically allocated ten beds to a Fast Track for low-acuity patients. We estimated the effect of a Flex Track policy, which involved switching up to five of these Fast Track beds to serving both low- and high-acuity patients, on patient waiting times. When the high-acuity beds were not at capacity, low-acuity patients were given priority access to flexible beds. Otherwise, high-acuity patients were given priority access to flexible beds. Wait times were estimated for patients by disposition and emergency severity index (ESI) score. Results A Flex Track policy using three flexible beds produced the lowest mean patient waiting of 30.9 (95% CI 30.6–31.2) minutes. The typical Fast Track approach of rigidly separating high- and low–acuity beds produced a mean patient wait time of 40.6 (95% CI 40.2–50.0) minutes, 31% higher than the three-bed Flex Track. A completely flexible ED, where all beds can accommodate any patient, produced mean wait times of 35.1 (95% CI 34.8–35.4) minutes. The results from the three-bed Flex Track scenario were robust, performing well across a range of scenarios involving higher and lower patient volumes and care durations. Conclusion Using discrete-event simulation, we have shown that adding some flexibility into bed allocation between low- and high-acuity can provide substantial reductions in overall patient waiting and a more efficient ED. PMID:24954578
Nonequilibrium Nonideal Nanoplasma Generated by a Fast Single Ion in Condensed Matter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faenov, A. Ya.; Kansai Photon Science Institut, Japan Atomic Energy Agency; Lankin, A. V.
A plasma model of relaxation of a medium in heavy ion tracks in condensed matter is proposed. The model is based on three assumptions: the Maxwell distribution of plasma electrons, localization of plasma inside the track nanochannel and constant values of the plasma electron density and temperature during the X-ray irradiation. It is demonstrated that the plasma relaxation model adequately describes the X-ray spectra observed upon interaction of a fast ion with condensed target. Preassumptions of plasma relaxation model are validated by the molecular dynamics modeling and simulation.
ERIC Educational Resources Information Center
Bermingham, Desmond
2011-01-01
The Education for All Fast Track Initiative (FTI) was launched by the World Bank in 2002 as a global initiative to help low income countries accelerate progress towards the MDG target of universal primary education by 2015. Over the past decade, the FTI has expanded to become one of the most important initiatives to emerge out of the Dakar World…
Fast track lunar NTR systems assessment for the First Lunar Outpost and its evolvability to Mars
NASA Technical Reports Server (NTRS)
Borowski, Stanley K.; Alexander, Stephen W.
1992-01-01
The objectives of the 'fast track' lunar Nuclear Thermal Rocket (NTR) analysis are to quantify necessary engine/stage characteristics to perform NASA's 'First Lunar Outpost' scenario and to assess the potential for evolution to Mars mission applications. By developing NTR/stage technologies for use in NASA's 'First Lunar Outpost' scenario, NASA will make a major down payment on the key components needed for the follow-on Mars Space Transportation System. A faster, cheaper approach to overall lunar/Mars exploration is expected.
Aerospace plane guidance using geometric control theory
NASA Technical Reports Server (NTRS)
Van Buren, Mark A.; Mease, Kenneth D.
1990-01-01
A reduced-order method employing decomposition, based on time-scale separation, of the 4-D state space in a 2-D slow manifold and a family of 2-D fast manifolds is shown to provide an excellent approximation to the full-order minimum-fuel ascent trajectory. Near-optimal guidance is obtained by tracking the reduced-order trajectory. The tracking problem is solved as regulation problems on the family of fast manifolds, using the exact linearization methodology from nonlinear geometric control theory. The validity of the overall guidance approach is indicated by simulation.
Exhausting Attentional Tracking Resources with a Single Fast-Moving Object
ERIC Educational Resources Information Center
Holcombe, Alex O.; Chen, Wei-Ying
2012-01-01
Driving on a busy road, eluding a group of predators, or playing a team sport involves keeping track of multiple moving objects. In typical laboratory tasks, the number of visual targets that humans can track is about four. Three types of theories have been advanced to explain this limit. The fixed-limit theory posits a set number of attentional…
U.S. masters track participation reveals a stable sex difference in competitiveness.
Deaner, Robert O; Addona, Vittorio; Mead, Michael P
2014-10-06
It is well established that men are more likely than women to engage in direct competition, but it is unclear if this reflects social structural conditions or evolved predispositions. These hypotheses can be addressed by quantifying competitiveness in sports and testing if the sex difference is decreasing over time in the U.S., a society where social roles have converged. Study 1 assessed participation and the occurrence of relatively fast performances by masters runners (40-74 years old) at recent road races and track meets. Fast performances occurred over 20 times more often at track meets than at road races. Women comprised 55% of finishers at roads races but only 15-28% of finishers at track meets. Thus, the sex difference in masters track participation can serve as a measure of the sex difference in competitiveness. Study 2 used data from national championship meets and yearly rankings lists to test whether the sex difference in masters track participation decreased from 1988-2012. The sex difference decreased overall, but there was no evidence of change since the late 1990s. Therefore, the sex difference in the willingness to engage in direct sports competition appears to reflect both social structural conditions and evolved predispositions.
A high-speed tracking algorithm for dense granular media
NASA Astrophysics Data System (ADS)
Cerda, Mauricio; Navarro, Cristóbal A.; Silva, Juan; Waitukaitis, Scott R.; Mujica, Nicolás; Hitschfeld, Nancy
2018-06-01
Many fields of study, including medical imaging, granular physics, colloidal physics, and active matter, require the precise identification and tracking of particle-like objects in images. While many algorithms exist to track particles in diffuse conditions, these often perform poorly when particles are densely packed together-as in, for example, solid-like systems of granular materials. Incorrect particle identification can have significant effects on the calculation of physical quantities, which makes the development of more precise and faster tracking algorithms a worthwhile endeavor. In this work, we present a new tracking algorithm to identify particles in dense systems that is both highly accurate and fast. We demonstrate the efficacy of our approach by analyzing images of dense, solid-state granular media, where we achieve an identification error of 5% in the worst evaluated cases. Going further, we propose a parallelization strategy for our algorithm using a GPU, which results in a speedup of up to 10 × when compared to a sequential CPU implementation in C and up to 40 × when compared to the reference MATLAB library widely used for particle tracking. Our results extend the capabilities of state-of-the-art particle tracking methods by allowing fast, high-fidelity detection in dense media at high resolutions.
ACC Effectiveness Review, 1999-2002.
ERIC Educational Resources Information Center
Wallace, Roslyn, Ed.
2002-01-01
These newsletters on Institutional Effectiveness (IE) at Austin Community College (ACC) in Texas include the following articles: (1) "The 'Fast Track'...Students Say It Works!" (2) "Are Students Successfully Completing Distance Learning Courses at ACC?" (3) "Tracking Transfers"; (4) "Math Pilot: Study Skills…
Linear Combination of Heuristics Approach to Spatial Sampling Hyperspectral Data for Target Tracking
2010-12-01
Figure 37 - Illustration of the tunable spectral polarimeter. ........................................... 154 Figure 38 - Illustration of micromirrors ...polarimeter. 9.2 Multiobject Tracking Spectrometer The idea of combining an array of MEMS micromirrors with an imager and a spectrometer array is the... micromirror array is located at an intermediate focal plane of the optical system. If all the individual mirrors are turned in the same direction
NASA Astrophysics Data System (ADS)
Coletta, Vincent P.; Evans, Jonathan
2008-10-01
We analyze the motion of a gravity powered model race car on a downhill track of variable slope. Using a simple algebraic function to approximate the height of the track as a function of the distance along the track, and taking account of the rotational energy of the wheels, rolling friction, and air resistance, we obtain analytic expressions for the velocity and time of the car as functions of the distance traveled along the track. Photogates are used to measure the time at selected points along the track, and the measured values are in excellent agreement with the values predicted from theory. The design and analysis of model race cars provides a good application of principles of mechanics and suggests interesting projects for classes in introductory and intermediate mechanics.
Spreading rate dependence of gravity anomalies along oceanic transform faults.
Gregg, Patricia M; Lin, Jian; Behn, Mark D; Montési, Laurent G J
2007-07-12
Mid-ocean ridge morphology and crustal accretion are known to depend on the spreading rate of the ridge. Slow-spreading mid-ocean-ridge segments exhibit significant crustal thinning towards transform and non-transform offsets, which is thought to arise from a three-dimensional process of buoyant mantle upwelling and melt migration focused beneath the centres of ridge segments. In contrast, fast-spreading mid-ocean ridges are characterized by smaller, segment-scale variations in crustal thickness, which reflect more uniform mantle upwelling beneath the ridge axis. Here we present a systematic study of the residual mantle Bouguer gravity anomaly of 19 oceanic transform faults that reveals a strong correlation between gravity signature and spreading rate. Previous studies have shown that slow-slipping transform faults are marked by more positive gravity anomalies than their adjacent ridge segments, but our analysis reveals that intermediate and fast-slipping transform faults exhibit more negative gravity anomalies than their adjacent ridge segments. This finding indicates that there is a mass deficit at intermediate- and fast-slipping transform faults, which could reflect increased rock porosity, serpentinization of mantle peridotite, and/or crustal thickening. The most negative anomalies correspond to topographic highs flanking the transform faults, rather than to transform troughs (where deformation is probably focused and porosity and alteration are expected to be greatest), indicating that crustal thickening could be an important contributor to the negative gravity anomalies observed. This finding in turn suggests that three-dimensional magma accretion may occur near intermediate- and fast-slipping transform faults.
Use of a genetic algorithm for the analysis of eye movements from the linear vestibulo-ocular reflex
NASA Technical Reports Server (NTRS)
Shelhamer, M.
2001-01-01
It is common in vestibular and oculomotor testing to use a single-frequency (sine) or combination of frequencies [sum-of-sines (SOS)] stimulus for head or target motion. The resulting eye movements typically contain a smooth tracking component, which follows the stimulus, in which are interspersed rapid eye movements (saccades or fast phases). The parameters of the smooth tracking--the amplitude and phase of each component frequency--are of interest; many methods have been devised that attempt to identify and remove the fast eye movements from the smooth. We describe a new approach to this problem, tailored to both single-frequency and sum-of-sines stimulation of the human linear vestibulo-ocular reflex. An approximate derivative is used to identify fast movements, which are then omitted from further analysis. The remaining points form a series of smooth tracking segments. A genetic algorithm is used to fit these segments together to form a smooth (but disconnected) wave form, by iteratively removing biases due to the missing fast phases. A genetic algorithm is an iterative optimization procedure; it provides a basis for extending this approach to more complex stimulus-response situations. In the SOS case, the genetic algorithm estimates the amplitude and phase values of the component frequencies as well as removing biases.
Stover, John; Bollinger, Lori; Izazola, Jose Antonio; Loures, Luiz; DeLay, Paul; Ghys, Peter D
2016-01-01
In 2011 a new Investment Framework was proposed that described how the scale-up of key HIV interventions could dramatically reduce new HIV infections and AIDS-related deaths in low and middle income countries by 2015. This framework included ambitious coverage goals for prevention and treatment services for 2015, resulting in a reduction of new HIV infections by more than half, in line with the goals of the declaration of the UN High Level Meeting in June 2011. However, the approach suggested a leveling in the number of new infections at about 1 million annually-far from the UNAIDS goal of ending AIDS by 2030. In response, UNAIDS has developed the Fast-Track approach that is intended to provide a roadmap to the actions required to achieve this goal. The Fast-Track approach is predicated on a rapid scale-up of focused, effective prevention and treatment services over the next 5 years and then maintaining a high level of programme implementation until 2030. Fast-Track aims to reduce new infections and AIDS-related deaths by 90% from 2010 to 2030 and proposes a set of biomedical, behavioral and enabling intervention targets for 2020 and 2030 to achieve that goal, including the rapid scale-up initiative for antiretroviral treatment known as 90-90-90. Compared to a counterfactual scenario of constant coverage for all services at early-2015 levels, the Fast-Track approach would avert 18 million HIV infections and 11 million deaths from 2016 to 2030 globally. This paper describes the analysis that produced these targets and the estimated resources needed to achieve them in low- and middle-income countries. It indicates that it is possible to achieve these goals with a significant push to achieve rapid scale-up of key interventions between now and 2020. The annual resources required from all sources would rise to US$7.4Bn in low-income countries, US$8.2Bn in lower middle-income countries and US$10.5Bn in upper-middle-income-countries by 2020 before declining approximately 9% by 2030.
Fast rise times and the physical mechanism of deep earthquakes
NASA Technical Reports Server (NTRS)
Houston, H.; Williams, Q.
1991-01-01
A systematic global survey of the rise times and stress drops of deep and intermediate earthquakes is reported. When the rise times are scaled to the seismic moment release of the events, their average is nearly twice as fast for events deeper than about 450 km as for shallower events.
Velocity-free attitude coordinated tracking control for spacecraft formation flying.
Hu, Qinglei; Zhang, Jian; Zhang, Youmin
2018-02-01
This article investigates the velocity-free attitude coordinated tracking control scheme for a group of spacecraft with the assumption that the angular velocities of the formation members are not available in control feedback. Initially, an angular velocity observer is constructed based on each individual's attitude quarternion. Then, the distributed attitude coordinated control law is designed by using the observed states, in which adaptive control method is adopted to handle the external disturbances. Stability of the overall closed-loop system is analyzed theoretically, which shows the system trajectory converges to a small set around origin with fast convergence rate. Numerical simulations are performed to demonstrate fast convergence and improved tracking performance of the proposed control strategy. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Teijeiro, Juan; Macías, Raúl J; Maragoto, Carlos; García, Iván; Alvarez, Mario; Quintanal, Nelson E
2014-01-01
Our objectives were to study the length of multi-unit recordings (MURs) of brain activity in 20 years of movement disorder neurosurgeries and to determine the number of times in which it was necessary for the teams using single-unit recording (SUR) to explore all the electrode tracks in the simultaneously recorded sites (SRS). This was a retrospective descriptive statistical analysis of MUR length on 4,296 tracks in 952 surgeries. The exclusion criteria were: tracks with fewer than 5 recorded signals, tracks that had a signal length different from the habitual 2s, or there being unusual situations not related to the MUR, as well as the first 20 surgeries of each surgical target. This yielded a total of 3,448 tracks in 805 surgeries. We also determined the number of the total 952 surgeries in which all the tracks in the SURs of the SRS were explored. The mean and its confidence interval (P=.05) of time per MUR track were 5.49±0.16min in subthalamic nucleus surgery, 8.82±0.24min in the medial or internal globus pallidus) and 18.51±1.31min in the ventral intermediate nucleus of the thalamus. For the total sum of tracks per surgery, in 75% of cases the total time was less than 39min in subthalamic nucleus, almost 42min in the medial or internal globus pallidus and less than 1h and 17min in ventral intermediate nucleus of the thalamus. All the tracks in the SUR SRS were explored in only 4.2% of the surgeries. The impact of MUR on surgical time is acceptable for this guide in objective localization for surgical targets, without having to use several simultaneous electrodes (not all indispensable in most of the cases). Consequently, there is less risk for the patient. Copyright © 2013 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shao, Michael; Nemati, Bijan; Zhai, Chengxing
We present an approach that significantly increases the sensitivity for finding and tracking small and fast near-Earth asteroids (NEAs). This approach relies on a combined use of a new generation of high-speed cameras which allow short, high frame-rate exposures of moving objects, effectively 'freezing' their motion, and a computationally enhanced implementation of the 'shift-and-add' data processing technique that helps to improve the signal-to-noise ratio (SNR) for detection of NEAs. The SNR of a single short exposure of a dim NEA is insufficient to detect it in one frame, but by computationally searching for an appropriate velocity vector, shifting successive framesmore » relative to each other and then co-adding the shifted frames in post-processing, we synthetically create a long-exposure image as if the telescope were tracking the object. This approach, which we call 'synthetic tracking,' enhances the familiar shift-and-add technique with the ability to do a wide blind search, detect, and track dim and fast-moving NEAs in near real time. We discuss also how synthetic tracking improves the astrometry of fast-moving NEAs. We apply this technique to observations of two known asteroids conducted on the Palomar 200 inch telescope and demonstrate improved SNR and 10 fold improvement of astrometric precision over the traditional long-exposure approach. In the past 5 yr, about 150 NEAs with absolute magnitudes H = 28 (∼10 m in size) or fainter have been discovered. With an upgraded version of our camera and a field of view of (28 arcmin){sup 2} on the Palomar 200 inch telescope, synthetic tracking could allow detecting up to 180 such objects per night, including very small NEAs with sizes down to 7 m.« less
First results of the silicon telescope using an 'artificial retina' for fast track finding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neri, N.; Abba, A.; Caponio, F.
We present the first results of the prototype of a silicon tracker with trigger capabilities based on a novel approach for fast track finding. The working principle of the 'artificial retina' is inspired by the processing of visual images by the brain and it is based on extensive parallelization of data distribution and pattern recognition. The algorithm has been implemented in commercial FPGAs in three main logic modules: a switch for the routing of the detector hits, a pool of engines for the digital processing of the hits, and a block for the calculation of the track parameters. The architecturemore » is fully pipelined and allows the reconstruction of real-time tracks with a latency less then 100 clock cycles, corresponding to 0.25 microsecond at 400 MHz clock. The silicon telescope consists of 8 layers of single-sided silicon strip detectors with 512 strips each. The detector size is about 10 cm x 10 cm and the strip pitch is 183 μm. The detectors are read out by the Beetle chip, a custom ASICs developed for LHCb, which provides the measurement of the hit position and pulse height of 128 channels. The 'artificial retina' algorithm has been implemented on custom data acquisition boards based on FPGAs Xilinx Kintex 7 lx160. The parameters of the tracks detected are finally transferred to host PC via USB 3.0. The boards manage the read-out ASICs and the sampling of the analog channels. The read-out is performed at 40 MHz on 4 channels for each ASIC that corresponds to a decoding of the telescope information at 1.1 MHz. We report on the first results of the fast tracking device and compare with simulations. (authors)« less
Three Hierarchies in Skeletal Muscle Fibre Classification Allotype, Isotype and Phenotype
NASA Technical Reports Server (NTRS)
Hoh, Joseph F. Y.; Hughes, Suzanne; Hugh, Gregory; Pozgaj, Irene
1991-01-01
Immunocytochemical analyses using specific anti-myosin antibodies of mammalian muscle fibers during regeneration, development, and after denervation have revealed two distinct myogenic components determining fiber phenotype. The jaw-closing muscles of the cat contain superfast fibers which express a unique myosin not found in limb muscles. When superfast muscle is transplanted into a limb muscle bed, regenerating myotubes synthesize superfast myosin independent of innervation. Reinnervation by the nerve to a fast muscle leads to the expression of superfast and not fast myosin, while reinnervation by the nerve to a slow muscle leads to the expression of a slow myosin. When limb muscle is transplanted into the jaw muscle bed, only limb myosins are synthesized. Thus jaw and limb muscles belong to distinct allotypes, each with a unique range of phenotype options, the expressions of which may be modulated by the nerve. Primary and secondary myotubes in developing jaw and limb muscles are observed to belong to different categories characterized by different patterns of myosin gene expression. By taking into consideration the pattern of myosins synthesized and the changes in fiber size after denervation, 3 types of primary (fast, slow, and intermediate) fibers can be distinguished in rat fast limb muscles. All primaries synthesize slow myosin soon after their formation, but this is withdrawn in fast and intermediate primaries at different times. After neonatal denervation, slow and intermediate primaries express slow primaries hypertrophy with other fibers atrophy. In the mature rat, the number of slow fibers in the EDL is less than the number of slow primaries. Upon denervation, hypertrophic slow fibers matching the number and topographic distribution of slow primaries appear, suggesting that a subpopulation of the slow primaries acquire the fast phenotype during adult life, but reveal their original identity as slow primaries in response to denervation by hypertrophying and synthesizing slow myosin. It is proposed that within each muscle allotype, the various isotypes of primary and secondary fibers are myogenically determined, and are derived from different lineage of myoblasts.
Real-Time Robust Tracking for Motion Blur and Fast Motion via Correlation Filters
Xu, Lingyun; Luo, Haibo; Hui, Bin; Chang, Zheng
2016-01-01
Visual tracking has extensive applications in intelligent monitoring and guidance systems. Among state-of-the-art tracking algorithms, Correlation Filter methods perform favorably in robustness, accuracy and speed. However, it also has shortcomings when dealing with pervasive target scale variation, motion blur and fast motion. In this paper we proposed a new real-time robust scheme based on Kernelized Correlation Filter (KCF) to significantly improve performance on motion blur and fast motion. By fusing KCF and STC trackers, our algorithm also solve the estimation of scale variation in many scenarios. We theoretically analyze the problem for CFs towards motions and utilize the point sharpness function of the target patch to evaluate the motion state of target. Then we set up an efficient scheme to handle the motion and scale variation without much time consuming. Our algorithm preserves the properties of KCF besides the ability to handle special scenarios. In the end extensive experimental results on benchmark of VOT datasets show our algorithm performs advantageously competed with the top-rank trackers. PMID:27618046
2013-01-01
This paper examines the effects of the Fast Track preventive intervention on youths’ functioning in three domains: disruptive behavior problems, involvement with deviant peers, and social skills during the middle school years. Eight hundred ninety-one children had been randomly assigned by sets of schools within four sites to intervention (n = 445) or to control (n = 446) conditions. In contrast to prior findings of the effectiveness of the Fast Track intervention during the elementary school years, the current findings indicate that Fast Track had little overall impact on children’s functioning in these domains during this age period. There were positive intervention effects on only 2 of 17 outcomes examined. Although the intervention had positive impact on children’s hyperactive and self-reported delinquent behaviors in seventh grade, there were no intervention effects on other externalizing behavior problems or on social skills, and there was a negative intervention effect on children’s involvement with deviant peers during this age period. PMID:24319308
F-16 MMC Strafe in Mountainous Terrain
2016-04-01
19 Figure 10. Steep fast (480 KIAS ) high-angle strafe...a fast (480 KIAS in this example) approach varies from the recovery radius (4000 feet in this case) and down track range prior to recovery initiation...Steep fast (480 KIAS ) high-angle strafe Alternate Analysis The F-16 community, to some extent, has adopted high-angle strafe as the de facto strafe
FastSim: A Fast Simulation for the SuperB Detector
NASA Astrophysics Data System (ADS)
Andreassen, R.; Arnaud, N.; Brown, D. N.; Burmistrov, L.; Carlson, J.; Cheng, C.-h.; Di Simone, A.; Gaponenko, I.; Manoni, E.; Perez, A.; Rama, M.; Roberts, D.; Rotondo, M.; Simi, G.; Sokoloff, M.; Suzuki, A.; Walsh, J.
2011-12-01
We have developed a parameterized (fast) simulation for detector optimization and physics reach studies of the proposed SuperB Flavor Factory in Italy. Detector components are modeled as thin sections of planes, cylinders, disks or cones. Particle-material interactions are modeled using simplified cross-sections and formulas. Active detectors are modeled using parameterized response functions. Geometry and response parameters are configured using xml files with a custom-designed schema. Reconstruction algorithms adapted from BaBar are used to build tracks and clusters. Multiple sources of background signals can be merged with primary signals. Pattern recognition errors are modeled statistically by randomly misassigning nearby tracking hits. Standard BaBar analysis tuples are used as an event output. Hadronic B meson pair events can be simulated at roughly 10Hz.
International collaborative project to compare and track the nutritional composition of fast foods.
2012-07-27
Chronic diseases are the leading cause of premature death and disability in the world with over-nutrition a primary cause of diet-related ill health. Excess quantities of energy, saturated fat, sugar and salt derived from fast foods contribute importantly to this disease burden. Our objective is to collate and compare nutrient composition data for fast foods as a means of supporting improvements in product formulation. Surveys of fast foods will be done in each participating country each year. Information on the nutrient composition for each product will be sought either through direct chemical analysis, from fast food companies, in-store materials or from company websites. Foods will be categorized into major groups for the primary analyses which will compare mean levels of saturated fat, sugar, sodium, energy and serving size at baseline and over time. Countries currently involved include Australia, New Zealand, France, UK, USA, India, Spain, China and Canada, with more anticipated to follow. This collaborative approach to the collation and sharing of data will enable low-cost tracking of fast food composition around the world. This project represents a significant step forward in the objective and transparent monitoring of industry and government commitments to improve the quality of fast foods.
UKIRT fast guide system improvements
NASA Astrophysics Data System (ADS)
Balius, Al; Rees, Nicholas P.
1997-09-01
The United Kingdom Infra-Red Telescope (UKIRT) has recently undergone the first major upgrade program since its construction. One part of the upgrade program was an adaptive tip-tilt secondary mirror closed with a CCD system collectively called the fast guide system. The installation of the new secondary and associated systems was carried out in the first half of 1996. Initial testing of the fast guide system has shown great improvement in guide accuracy. The initial installation included a fixed integration time CCD. In the first part of 1997 an integration time controller based on computed guide star luminosity was implemented in the fast guide system. Also, a Kalman type estimator was installed in the image tracking loop based on a dynamic model and knowledge of the statistical properties of the guide star position error measurement as a function of computed guide star magnitude and CCD integration time. The new configuration was tested in terms of improved guide performance nd graceful degradation when tracking faint guide stars. This paper describes the modified fast guide system configuration and reports the results of performance tests.
Fast food consumption and gestational diabetes incidence in the SUN project.
Dominguez, Ligia J; Martínez-González, Miguel A; Basterra-Gortari, Francisco Javier; Gea, Alfredo; Barbagallo, Mario; Bes-Rastrollo, Maira
2014-01-01
Gestational diabetes prevalence is increasing, mostly because obesity among women of reproductive age is continuously escalating. We aimed to investigate the incidence of gestational diabetes according to the consumption of fast food in a cohort of university graduates. The prospective dynamic "Seguimiento Universidad de Navarra" (SUN) cohort included data of 3,048 women initially free of diabetes or previous gestational diabetes who reported at least one pregnancy between December 1999 and March 2011. Fast food consumption was assessed through a validated 136-item semi-quantitative food frequency questionnaire. Fast food was defined as the consumption of hamburgers, sausages, and pizza. Three categories of fast food were established: low (0-3 servings/month), intermediate (>3 servings/month and ≤2 servings/week) and high (>2 servings/week). Non-conditional logistic regression models were used to adjust for potential confounders. We identified 159 incident cases of gestational diabetes during follow-up. After adjusting for age, baseline body mass index, total energy intake, smoking, physical activity, family history of diabetes, cardiovascular disease/hypertension at baseline, parity, adherence to Mediterranean dietary pattern, alcohol intake, fiber intake, and sugar-sweetened soft drinks consumption, fast food consumption was significantly associated with a higher risk of incident gestational diabetes, with multivariate adjusted OR of 1.31 (95% conficence interval [CI]:0.81-2.13) and 1.86 (95% CI: 1.13-3.06) for the intermediate and high categories, respectively, versus the lowest category of baseline fast food consumption (p for linear trend: 0.007). Our results suggest that pre-pregnancy higher consumption of fast food is an independent risk factor for gestational diabetes.
Liu, Xinyang; Plishker, William; Zaki, George; Kang, Sukryool; Kane, Timothy D.; Shekhar, Raj
2017-01-01
Purpose Common camera calibration methods employed in current laparoscopic augmented reality systems require the acquisition of multiple images of an entire checkerboard pattern from various poses. This lengthy procedure prevents performing laparoscope calibration in the operating room (OR). The purpose of this work was to develop a fast calibration method for electromagnetically (EM) tracked laparoscopes, such that calibration can be performed in the OR on demand. Methods We designed a mechanical tracking mount to uniquely and snugly position an EM sensor to an appropriate location on a conventional laparoscope. A tool named fCalib was developed to calibrate intrinsic camera parameters, distortion coefficients, and extrinsic parameters (transformation between the scope lens coordinate system and the EM sensor coordinate system) using a single image that shows an arbitrary portion of a special target pattern. For quick evaluation of calibration result in the OR, we integrated a tube phantom with fCalib and overlaid a virtual representation of the tube on the live video scene. Results We compared spatial target registration error between the common OpenCV method and the fCalib method in a laboratory setting. In addition, we compared the calibration re-projection error between the EM tracking-based fCalib and the optical tracking-based fCalib in a clinical setting. Our results suggested that the proposed method is comparable to the OpenCV method. However, changing the environment, e.g., inserting or removing surgical tools, would affect re-projection accuracy for the EM tracking-based approach. Computational time of the fCalib method averaged 14.0 s (range 3.5 s – 22.7 s). Conclusions We developed and validated a prototype for fast calibration and evaluation of EM tracked conventional (forward viewing) laparoscopes. The calibration method achieved acceptable accuracy and was relatively fast and easy to be performed in the OR on demand. PMID:27250853
Liu, Xinyang; Plishker, William; Zaki, George; Kang, Sukryool; Kane, Timothy D; Shekhar, Raj
2016-06-01
Common camera calibration methods employed in current laparoscopic augmented reality systems require the acquisition of multiple images of an entire checkerboard pattern from various poses. This lengthy procedure prevents performing laparoscope calibration in the operating room (OR). The purpose of this work was to develop a fast calibration method for electromagnetically (EM) tracked laparoscopes, such that the calibration can be performed in the OR on demand. We designed a mechanical tracking mount to uniquely and snugly position an EM sensor to an appropriate location on a conventional laparoscope. A tool named fCalib was developed to calibrate intrinsic camera parameters, distortion coefficients, and extrinsic parameters (transformation between the scope lens coordinate system and the EM sensor coordinate system) using a single image that shows an arbitrary portion of a special target pattern. For quick evaluation of calibration results in the OR, we integrated a tube phantom with fCalib prototype and overlaid a virtual representation of the tube on the live video scene. We compared spatial target registration error between the common OpenCV method and the fCalib method in a laboratory setting. In addition, we compared the calibration re-projection error between the EM tracking-based fCalib and the optical tracking-based fCalib in a clinical setting. Our results suggest that the proposed method is comparable to the OpenCV method. However, changing the environment, e.g., inserting or removing surgical tools, might affect re-projection accuracy for the EM tracking-based approach. Computational time of the fCalib method averaged 14.0 s (range 3.5 s-22.7 s). We developed and validated a prototype for fast calibration and evaluation of EM tracked conventional (forward viewing) laparoscopes. The calibration method achieved acceptable accuracy and was relatively fast and easy to be performed in the OR on demand.
Photon ratchet intermediate band solar cells
NASA Astrophysics Data System (ADS)
Yoshida, M.; Ekins-Daukes, N. J.; Farrell, D. J.; Phillips, C. C.
2012-06-01
In this paper, we propose an innovative concept for solar power conversion—the "photon ratchet" intermediate band solar cell (IBSC)—which may increase the photovoltaic energy conversion efficiency of IBSCs by increasing the lifetime of charge carriers in the intermediate state. The limiting efficiency calculation for this concept shows that the efficiency can be increased by introducing a fast thermal transition of carriers into a non-emissive state. At 1 sun, the introduction of a "ratchet band" results in an increase of efficiency from 46.8% to 48.5%, due to suppression of entropy generation.
Extraction of line properties based on direction fields.
Kutka, R; Stier, S
1996-01-01
The authors present a new set of algorithms for segmenting lines, mainly blood vessels in X-ray images, and extracting properties such as their intensities, diameters, and center lines. The authors developed a tracking algorithm that checks rules taking the properties of vessels into account. The tools even detect veins, arteries, or catheters of two pixels in diameter and with poor contrast. Compared with other algorithms, such as the Canny line detector or anisotropic diffusion, the authors extract a smoother and connected vessel tree without artifacts in the image background. As the tools depend on common intermediate results, they are very fast when used together. The authors' results will support the 3-D reconstruction of the vessel tree from stereoscopic projections. Moreover, the authors make use of their line intensity measure for enhancing and improving the visibility of vessels in 3-D X-ray images. The processed images are intended to support radiologists in diagnosis, radiation therapy planning, and surgical planning. Radiologists verified the improved quality of the processed images and the enhanced visibility of relevant details, particularly fine blood vessels.
The use of ultrasonic properties of CR-39 track detectors in neutron dosimetry
NASA Astrophysics Data System (ADS)
Afifi, H.; El-Sersy, A.; Khaled, N.
2004-01-01
The longitudinal and shear wave ultrasonic velocities have been measured before and after exposing 5-mm thick CR-39 solid state nuclear track detectors to both a mixed field of gamma-rays and fast neutrons from an Am-Be source in the ranges from 0 to 10 4 mSv. The change in the intermolecular structure as caused by the fast neutron exposure was studied by the ultrasonic pulse echo method at a frequency of 2 MHz and at room temperature. The elastic coefficients, Poisson's ratio, microhardness, ultrasonic absorption coefficient and internal friction have been determined. The study shows that the gamma-ray irradiation had no effect on the ultrasonic properties of CR-39 at least at the used doses. However, all the ultrasonic properties are influenced by the fast neutrons at doses up to 10 4 mSv. Our experimental results confirmed that the ultrasonic technique is useful for fast neutron detection, by exploiting the differences in mechanical properties of CR-39.
Global fast dynamic terminal sliding mode control for a quadrotor UAV.
Xiong, Jing-Jing; Zhang, Guo-Bao
2017-01-01
A control method based on global fast dynamic terminal sliding mode control (TSMC) technique is proposed to design the flight controller for performing the finite-time position and attitude tracking control of a small quadrotor UAV. Firstly, the dynamic model of the quadrotor is divided into two subsystems, i.e., a fully actuated subsystem and an underactuated subsystem. Secondly, the dynamic flight controllers of the quadrotor are formulated based on global fast dynamic TSMC, which is able to guarantee that the position and velocity tracking errors of all system state variables converge to zero in finite-time. Moreover, the global fast dynamic TSMC is also able to eliminate the chattering phenomenon caused by the switching control action and realize the high precision performance. In addition, the stabilities of two subsystems are demonstrated by Lyapunov theory, respectively. Lastly, the simulation results are given to illustrate the effectiveness and robustness of the proposed control method in the presence of external disturbances. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Motion-Blur-Free High-Speed Video Shooting Using a Resonant Mirror
Inoue, Michiaki; Gu, Qingyi; Takaki, Takeshi; Ishii, Idaku; Tajima, Kenji
2017-01-01
This study proposes a novel concept of actuator-driven frame-by-frame intermittent tracking for motion-blur-free video shooting of fast-moving objects. The camera frame and shutter timings are controlled for motion blur reduction in synchronization with a free-vibration-type actuator vibrating with a large amplitude at hundreds of hertz so that motion blur can be significantly reduced in free-viewpoint high-frame-rate video shooting for fast-moving objects by deriving the maximum performance of the actuator. We develop a prototype of a motion-blur-free video shooting system by implementing our frame-by-frame intermittent tracking algorithm on a high-speed video camera system with a resonant mirror vibrating at 750 Hz. It can capture 1024 × 1024 images of fast-moving objects at 750 fps with an exposure time of 0.33 ms without motion blur. Several experimental results for fast-moving objects verify that our proposed method can reduce image degradation from motion blur without decreasing the camera exposure time. PMID:29109385
Three-dimensional reconstruction of the fast-start swimming kinematics of densely schooling fish
Paley, Derek A.
2012-01-01
Information transmission via non-verbal cues such as a fright response can be quantified in a fish school by reconstructing individual fish motion in three dimensions. In this paper, we describe an automated tracking framework to reconstruct the full-body trajectories of densely schooling fish using two-dimensional silhouettes in multiple cameras. We model the shape of each fish as a series of elliptical cross sections along a flexible midline. We estimate the size of each ellipse using an iterated extended Kalman filter. The shape model is used in a model-based tracking framework in which simulated annealing is applied at each step to estimate the midline. Results are presented for eight fish with occlusions. The tracking system is currently being used to investigate fast-start behaviour of schooling fish in response to looming stimuli. PMID:21642367
Fault Tolerant Signal Processing Using Finite Fields and Error-Correcting Codes.
1983-06-01
Decimation in Frequency Form, Fast Inverse Transform F-18 F-4 Part of Decimation in Time Form, Fast Inverse Transform F-21 I . LIST OF TABLES fable Title Page...F-2 Intermediate Variables In A Fast Inverse Transform F-14 Accession For NTIS GRA&il DTIC TAB E Unannounced El ** Dist ribut ion/ ____ AvailabilitY...component polynomials may be transformed to an equiva- lent series of multiplications of the related transform ’.. coefficients. The inverse transform of
Analysis of three advanced practice roles in emergency nursing.
Considine, Julie; Lucas, Elspeth; Payne, Roslyn; Kropman, Matthew; Stergiou, Helen E; Chiu, Herman
2012-11-01
There are many Emergency Department (ED) demand management systems that include advanced practice emergency nursing roles. The aim of this study is to examine and compare three advanced emergency nursing practice roles: ED Fast Track, Clinical Initiatives Nurse (CIN) and Rapid Intervention and Treatment Zone (RITZ). A descriptive exploratory approach was used to conduct this study at an urban district hospital in Melbourne, Australia. The study participants were patients managed in each of the three systems with advanced practice emergency nursing roles: Fast Track, CIN and RITZ. There were a total of 551 patients: 195 Fast Track patients, 163 CIN managed patients and 193 RITZ patients. CIN managed patients were older (p<0.001), with higher levels of clinical urgency (p<0.001), and higher hospital admission rates (p<0.001). CIN managed patients had shorter waiting time for nursing care (p=0.001) and lower incidence of medical assessment within the time associated with their triage category (p<0.0001). ED LOS for discharged patients was significantly longer for CIN managed patients (p<0.001). CIN managed patients had a significantly higher incidence of electrocardiography (p<0.001), blood glucose measurement (p<0.001), intravenous cannulation (p<0.001), pathology testing (p<0.001), and analgesia administration (p<0.001) when compared to Fast Track and RITZ patients. Advanced practice roles in emergency nursing can have different applications in the ED context. Clarity about role intent and scope of practice is important and should inform educational preparation and teams within which these roles operate. Copyright © 2012 College of Emergency Nursing Australasia Ltd. Published by Elsevier Ltd. All rights reserved.
Rhou, Yoon J J; Pather, Selvan; Loadsman, John A; Campbell, Neil; Philp, Shannon; Carter, Jonathan
2015-12-01
To assess the direct intraoperative and postoperative costs in women undergoing total laparoscopic hysterectomy and fast-track open hysterectomy. A retrospective review of the direct hospital-related costs in a matched cohort of women undergoing total laparoscopic hysterectomy (TLH) and fast-track open hysterectomy (FTOH) at a tertiary hospital. All costs were calculated, including the cost of advanced high-energy laparoscopic devices. The effect of the learning curve on cost in laparoscopic hysterectomy was also assessed, as was the hospital case-weighted cost, which was compared with the actual cost. Fifty women were included in each arm of the study. TLH had a higher intraoperative cost, but a lower postoperative cost than FTOH (AUD$3877 vs AUD$2776 P < 0.001, AUD$3965 vs AUD$6233 P < 0.001). The total cost of TLH was not different from FTOH (AUD$7842 vs AUD$9009 P = 0.068) and after a learning curve; TLH cost less than FTOH (AUD$6797 vs AUD$8647, P < 0.001). The use of high-energy devices did not impact on the cost benefit of TLH, and hospital case-weight-based funding correlated poorly with actual cost. Despite the use of fast-track recovery protocols, the cost of TLH is no different to FTOH and after a learning curve is cheaper than open hysterectomy. Judicious use of advanced energy devices does not impact on the cost, and hospital case-weight-based funding model in our hospital is inaccurate when compared to directly calculated hospital costs. © 2013 The Authors ANZJOG © 2013 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.
Energy Dynamics: A Fast Track Inquiry
ERIC Educational Resources Information Center
Schmidt, Stan M.; Hrynyshyn, Alec
2004-01-01
Students investigate energy conversions by collaborating to develop a free standing track of plastic tubing through which a ball bearing moves at the fastest possible speed. Friendly competition leads to discussion of what worked and did not work and to the identification and investigation of underlying principles. (Contains 4 charts.)
Weisshaar, D.; Bazin, D.; Bender, P. C.; ...
2016-12-03
The gamma-ray tracking array GRETINA was coupled to the S800 magnetic spectrometer for spectroscopy with fast beams of rare isotopes at the National Superconducting Cyclotron Laboratory on the campus of Michigan State University. We describe the technical details of this powerful setup and report on GRETINA's performance achieved with source and in-beam measurements. The gamma-ray multiplicity encountered in experiments with fast beams is usually low, allowing for a simplified and efficient treatment of the data in the gamma-ray analysis in terms of Doppler reconstruction and spectral quality. Finally, the results reported in this work were obtained from GRETINA consisting ofmore » 8 detector modules hosting four high-purity germanium crystals each. Currently, GRETINA consists of 10 detector modules.« less
An object detection and tracking system for unmanned surface vehicles
NASA Astrophysics Data System (ADS)
Yang, Jian; Xiao, Yang; Fang, Zhiwen; Zhang, Naiwen; Wang, Li; Li, Tao
2017-10-01
Object detection and tracking are critical parts of unmanned surface vehicles(USV) to achieve automatic obstacle avoidance. Off-the-shelf object detection methods have achieved impressive accuracy in public datasets, though they still meet bottlenecks in practice, such as high time consumption and low detection quality. In this paper, we propose a novel system for USV, which is able to locate the object more accurately while being fast and stable simultaneously. Firstly, we employ Faster R-CNN to acquire several initial raw bounding boxes. Secondly, the image is segmented to a few superpixels. For each initial box, the superpixels inside will be grouped into a whole according to a combination strategy, and a new box is thereafter generated as the circumscribed bounding box of the final superpixel. Thirdly, we utilize KCF to track these objects after several frames, Faster-RCNN is again used to re-detect objects inside tracked boxes to prevent tracking failure as well as remove empty boxes. Finally, we utilize Faster R-CNN to detect objects in the next image, and refine object boxes by repeating the second module of our system. The experimental results demonstrate that our system is fast, robust and accurate, which can be applied to USV in practice.
Fast track in colo-rectal surgery. Preliminary experience in a rural hospital
FRONTERA, D.; ARENA, L.; CORSALE, I.; FRANCIOLI, N.; MAMMOLITI, F.; BUCCIANELLI, E.
2014-01-01
Background “Fast Track surgery” is a therapeutic program of large application, despite some doubts about its applicability and real validity. Literature review shows that this approach to colo-rectal surgery, particularly video-assisted, can allow a rapid recovery, better performance and a faster postoperative functional autonomy of the work, which can be discharged without cause additional welfare costs; in addition it can be reproducible in different health reality. Purpose To analyze the possibility to apply the Fast Truck protocol in patients undergoing colorectal surgery in a rural hospital and non specialistic Unit of Surgery. Patients and methods We have conducted a prospective, randomized study on 80 patients subjected to colorectal surgery in the last year. Results The protocol was observed in 95% of cases, compliance with the Fast Track was high and general morbidity was limited (7.8%). Conclusion This “aggressive” approach, which has fundamentally altered the usual surgical behavior, seems to allow a mean length of stay significantly lower than in controls (p < 0.05) with positive implications for patients and containment of health care costs, even after discharge (no need for home care in 92% of cases, no early re-admittance to the hospital). Homogeneous protocols are desirable, as well as an increased enrollment, to consolidate these rehabilitation programs in order to provide a reference for all hospitals. PMID:25644732
Electronic properties of solids excited with intermediate laser power densities
NASA Astrophysics Data System (ADS)
Sirotti, Fausto; Tempo Beamline Team
Intermediate laser power density up to about 100 GW/cm2 is below the surface damage threshold is currently used to induce modification in the physical properties on short time scales. The absorption of a short laser pulse induces non-equilibrium electronic distributions followed by lattice-mediated equilibrium taking place only in the picosecond range. The role of the hot electrons is particularly important in several domains as for example fast magnetization and demagnetization processes, laser induced phase transitions, charge density waves. Angular resolved photoelectron spectroscopy measuring directly energy and momentum of electrons is the most adapted tool to study the electronic excitations at short time scales during and after fast laser excitations. The main technical problem is the space charge created by the pumping laser pulse. I will present angular resolved multiphoton photoemission results obtained with 800 nm laser pulses showing how space charge electrons emitted during fast demagnetization processes can be measured. Unable enter Affiliation: CNRS-SOLEIL Synchrotron L'Orme des Merisiers , Saint Aubin 91192 Gif sur Yvette France.
The flex track: flexible partitioning between low- and high-acuity areas of an emergency department.
Laker, Lauren F; Froehle, Craig M; Lindsell, Christopher J; Ward, Michael J
2014-12-01
Emergency departments (EDs) with both low- and high-acuity treatment areas often have fixed allocation of resources, regardless of demand. We demonstrate the utility of discrete-event simulation to evaluate flexible partitioning between low- and high-acuity ED areas to identify the best operational strategy for subsequent implementation. A discrete-event simulation was used to model patient flow through a 50-bed, urban, teaching ED that handles 85,000 patient visits annually. The ED has historically allocated 10 beds to a fast track for low-acuity patients. We estimated the effect of a flex track policy, which involved switching up to 5 of these fast track beds to serving both low- and high-acuity patients, on patient waiting times. When the high-acuity beds were not at capacity, low-acuity patients were given priority access to flexible beds. Otherwise, high-acuity patients were given priority access to flexible beds. Wait times were estimated for patients by disposition and Emergency Severity Index score. A flex track policy using 3 flexible beds produced the lowest mean patient waiting time of 30.9 minutes (95% confidence interval [CI] 30.6 to 31.2 minutes). The typical fast track approach of rigidly separating high- and low-acuity beds produced a mean patient wait time of 40.6 minutes (95% CI 40.2 to 50.0 minutes), 31% higher than that of the 3-bed flex track. A completely flexible ED, in which all beds can accommodate any patient, produced mean wait times of 35.1 minutes (95% CI 34.8 to 35.4 minutes). The results from the 3-bed flex track scenario were robust, performing well across a range of scenarios involving higher and lower patient volumes and care durations. Using discrete-event simulation, we have shown that adding some flexibility into bed allocation between low and high acuity can provide substantial reductions in overall patient waiting and a more efficient ED. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Dual linear structured support vector machine tracking method via scale correlation filter
NASA Astrophysics Data System (ADS)
Li, Weisheng; Chen, Yanquan; Xiao, Bin; Feng, Chen
2018-01-01
Adaptive tracking-by-detection methods based on structured support vector machine (SVM) performed well on recent visual tracking benchmarks. However, these methods did not adopt an effective strategy of object scale estimation, which limits the overall tracking performance. We present a tracking method based on a dual linear structured support vector machine (DLSSVM) with a discriminative scale correlation filter. The collaborative tracker comprised of a DLSSVM model and a scale correlation filter obtains good results in tracking target position and scale estimation. The fast Fourier transform is applied for detection. Extensive experiments show that our tracking approach outperforms many popular top-ranking trackers. On a benchmark including 100 challenging video sequences, the average precision of the proposed method is 82.8%.
A maximum power point tracking algorithm for buoy-rope-drum wave energy converters
NASA Astrophysics Data System (ADS)
Wang, J. Q.; Zhang, X. C.; Zhou, Y.; Cui, Z. C.; Zhu, L. S.
2016-08-01
The maximum power point tracking control is the key link to improve the energy conversion efficiency of wave energy converters (WEC). This paper presents a novel variable step size Perturb and Observe maximum power point tracking algorithm with a power classification standard for control of a buoy-rope-drum WEC. The algorithm and simulation model of the buoy-rope-drum WEC are presented in details, as well as simulation experiment results. The results show that the algorithm tracks the maximum power point of the WEC fast and accurately.
Fast and Accurate Cell Tracking by a Novel Optical-Digital Hybrid Method
NASA Astrophysics Data System (ADS)
Torres-Cisneros, M.; Aviña-Cervantes, J. G.; Pérez-Careta, E.; Ambriz-Colín, F.; Tinoco, Verónica; Ibarra-Manzano, O. G.; Plascencia-Mora, H.; Aguilera-Gómez, E.; Ibarra-Manzano, M. A.; Guzman-Cabrera, R.; Debeir, Olivier; Sánchez-Mondragón, J. J.
2013-09-01
An innovative methodology to detect and track cells using microscope images enhanced by optical cross-correlation techniques is proposed in this paper. In order to increase the tracking sensibility, image pre-processing has been implemented as a morphological operator on the microscope image. Results show that the pre-processing process allows for additional frames of cell tracking, therefore increasing its robustness. The proposed methodology can be used in analyzing different problems such as mitosis, cell collisions, and cell overlapping, ultimately designed to identify and treat illnesses and malignancies.
Trajectory tracking and backfitting techniques against theater ballistic missiles
NASA Astrophysics Data System (ADS)
Hutchins, Robert G.; Britt, Patrick T.
1999-10-01
Since the SCUD launches in the Gulf War, theater ballistic missile (TBM) systems have become a growing concern for the US military. Detection, fast track initiation, backfitting for launch point determination, and tracking and engagement during boost phase or shortly after booster cutoff are goals that grow in importance with the proliferation of weapons of mass destruction. This paper focuses on track initiation and backfitting techniques, as well as extending some earlier results on tracking a TBM during boost phase cutoff. Results indicate that Kalman techniques are superior to third order polynomial extrapolations in estimating the launch point, and that some knowledge of missile parameters, especially thrust, is extremely helpful in track initiation.
Fast Deep Tracking via Semi-Online Domain Adaptation
NASA Astrophysics Data System (ADS)
Li, Xiaoping; Luo, Wenbing; Zhu, Yi; Li, Hanxi; Wang, Mingwen
2018-04-01
Deep tracking has been illustrating overwhelming superiorities over the shallow methods. Unfortunately, it also suffers from low FPS rates. To alleviate the problem, a number of real-time deep trackers have been proposed via removing the online updating procedure on the CNN model. However, the absent of the online update leads to a significant drop on tracking accuracy. In this work, we propose to perform the domain adaptation for visual tracking in two stages for transferring the information from the visual tracking domain and the instance domain respectively. In this way, the proposed visual tracker achieves comparable tracking accuracy to the state-of-the-art trackers and runs at real-time speed on an average consuming GPU.
Tracking multiple objects is limited only by object spacing, not by speed, time, or capacity.
Franconeri, S L; Jonathan, S V; Scimeca, J M
2010-07-01
In dealing with a dynamic world, people have the ability to maintain selective attention on a subset of moving objects in the environment. Performance in such multiple-object tracking is limited by three primary factors-the number of objects that one can track, the speed at which one can track them, and how close together they can be. We argue that this last limit, of object spacing, is the root cause of all performance constraints in multiple-object tracking. In two experiments, we found that as long as the distribution of object spacing is held constant, tracking performance is unaffected by large changes in object speed and tracking time. These results suggest that barring object-spacing constraints, people could reliably track an unlimited number of objects as fast as they could track a single object.
More Water, Madam? An ESL Curriculum for Service Helpers in Full-Service and Fast-Food Restaurants.
ERIC Educational Resources Information Center
Cwach, Marlin Day; Gravely, Mary Liles
This document, which was developed as a cooperative effort between the business and education communities in Denver, presents an English-as-a-second-language curriculum for service helpers in full-service and fast food restaurants. The curriculum consists of five lessons targeted toward high intermediate to advanced nonnative speakers who work in…
Fast Track to the Cloud: Design Patterns for 12-Factor Earth Sciences Applications
NASA Technical Reports Server (NTRS)
Pawloski, Andrew; McLaughlin, Brett; Lynnes, Christopher
2016-01-01
As expanding service offerings and decreasing prices make the cloud increasingly attractive to Earth Science applications, there are nontrivial practical considerations which can hinder its meaningful use. In this talk, we will discuss architectural recommendations and lessons learned while working on EOSDIS' cloud efforts, particularly the NASA-compliant General Application Platform (NGAP) and its associated applications. Prominent in our findings is the importance of 12-factor design patterns and the powerful "wins" they enable in the cloud. We will share our strategies for "fast-tracking" applications to the cloud --whether they be legacy, planned for the future, or somewhere in between.
Returning nurses to the workforce: developing a fast track back program.
Burns, Helen K; Sakraida, Teresa J; Englert, Nadine C; Hoffmann, Rosemary L; Tuite, Patricia; Foley, Susan M
2006-01-01
Fast Track Back: Re-entry into Nursing Practice program. Describes the development, implementation, and evaluation of a state-of-the-art re-entry program facilitating the return of licensed nonpracticing RNs to the workforce through a quality education program that retools them for the workforce in the areas of pharmacology, skill development using the latest technology, practice standards, and nursing issues. The program consists of didactic content taught via classroom, Internet, skills laboratory, and high fidelity human simulated technology and a clinical component. The program is a mechanism that enables re-entry nurses to improve skills and competencies necessary to practice in today's healthcare environment.
Hasenberg, T; Keese, M; Längle, F; Reibenwein, B; Schindler, K; Herold, A; Beck, G; Post, S; Jauch, K W; Spies, C; Schwenk, W; Shang, E
2009-02-01
'Fast-track' rehabilitation has been shown to accelerate recovery, reduce general morbidity and decrease hospital stay after elective colonic surgery. Despite this evidence, there is no information on the acceptance and utilization of these concepts among the entirety of Austrian and German surgeons. In 2006, a questionnaire concerning perioperative routines in elective, open colonic resection was sent to the chief surgeons of 1270 German and 120 Austrian surgical centres. The response rate was 63% in Austria (76 centres) and 30% in Germany (385 centres). Mechanical bowel preparation is used by the majority (Austria, 91%; Germany, 94%); the vertical incision is the standard method of approach to the abdomen in Austria (79%) and Germany (83%), nasogastric decompression tubes are rarely used, one-third of the questioned surgeons in both countries use intra-abdominal drains. Half of the surgical centres allow the intake of clear fluids on the day of surgery and one-fifth offer solid food on that day. Epidural analgesia is used in three-fourths of the institutions. Although there is an evident benefit of fast-track management, the survey shows that they are not yet widely used as a routine in Austria and Germany.
A Fast Track approach to deal with the temporal dimension of crop water footprint
NASA Astrophysics Data System (ADS)
Tuninetti, Marta; Tamea, Stefania; Laio, Francesco; Ridolfi, Luca
2017-07-01
Population growth, socio-economic development and climate changes are placing increasing pressure on water resources. Crop water footprint is a key indicator in the quantification of such pressure. It is determined by crop evapotranspiration and crop yield, which can be highly variable in space and time. While the spatial variability of crop water footprint has been the objective of several investigations, the temporal variability remains poorly studied. In particular, some studies approached this issue by associating the time variability of crop water footprint only to yield changes, while considering evapotranspiration patterns as marginal. Validation of this Fast Track approach has yet to be provided. In this Letter we demonstrate its feasibility through a comprehensive validation, an assessment of its uncertainty, and an example of application. Our results show that the water footprint changes are mainly driven by yield trends, while evapotranspiration plays a minor role. The error due to considering constant evapotranspiration is three times smaller than the uncertainty of the model used to compute the crop water footprint. These results confirm the suitability of the Fast Track approach and enable a simple, yet appropriate, evaluation of time-varying crop water footprint.
Albert, Dustin; Belsky, Daniel W.; Crowley, D. Max; Latendresse, Shawn J.; Aliev, Fazil; Riley, Brien; Sun, Cuie; Dick, Danielle M.; Dodge, Kenneth R.
2014-01-01
Early interventions are a preferred method for addressing behavioral problems in high-risk children, but often have only modest effects. Identifying sources of variation in intervention effects can suggest means to improve efficiency. One potential source of such variation is the genome. We conducted a genetic analysis of the Fast Track Randomized Control Trial, a 10-year-long intervention to prevent high-risk kindergarteners from developing adult externalizing problems including substance abuse and antisocial behavior. We tested whether variants of the glucocorticoid receptor gene NR3C1 were associated with differences in response to the Fast Track intervention. We found that in European-American children, a variant of NR3C1 identified by the single-nucleotide polymorphism rs10482672 was associated with increased risk for externalizing psychopathology in control group children and decreased risk for externalizing psychopathology in intervention group children. Variation in NR3C1 measured in this study was not associated with differential intervention response in African-American children. We discuss implications for efforts to prevent externalizing problems in high-risk children and for public policy in the genomic era. PMID:26106668
The use of a break-even analysis: financial analysis of a fast-track program.
Saywell, R M; Cordell, W H; Nyhuis, A W; Giles, B K; Culler, S D; Woods, J R; Chu, D K; McKinzie, J P; Rodman, G H
1995-08-01
To calculate the financial break-even point and illustrate how changes in third-party reimbursement and eligibility could affect a program's fiscal standing. Demographic, clinical, and financial data were collected retrospectively for 446 patients treated in a fast-track program during June 1993. The fast-track program is located within the confines of the emergency medicine and trauma center at a 1,050-bed tertiary care Midwestern teaching hospital and provides urgent treatment to minimally ill patients. A financial break-even analysis was performed to determine the point where the program generated enough revenue to cover its total variable and fixed costs, both direct and indirect. Given the relatively low average collection rate (62%) and high percentage of uninsured patients (31%), the analysis showed that the program's revenues covered its direct costs but not all of the indirect costs. Examining collection rates or payer class mix without examining both costs and revenues may lead to an erroneous conclusion about a program's fiscal viability. Sensitivity analysis also shows that relatively small changes in third-party coverage or eligibility (income) requirements can have a large impact on the program's financial solvency and break-even volumes.
A hardware fast tracker for the ATLAS trigger
NASA Astrophysics Data System (ADS)
Asbah, Nedaa
2016-09-01
The trigger system of the ATLAS experiment is designed to reduce the event rate from the LHC nominal bunch crossing at 40 MHz to about 1 kHz, at the design luminosity of 1034 cm-2 s-1. After a successful period of data taking from 2010 to early 2013, the LHC already started with much higher instantaneous luminosity. This will increase the load on High Level Trigger system, the second stage of the selection based on software algorithms. More sophisticated algorithms will be needed to achieve higher background rejection while maintaining good efficiency for interesting physics signals. The Fast TracKer (FTK) is part of the ATLAS trigger upgrade project. It is a hardware processor that will provide, at every Level-1 accepted event (100 kHz) and within 100 microseconds, full tracking information for tracks with momentum as low as 1 GeV. Providing fast, extensive access to tracking information, with resolution comparable to the offline reconstruction, FTK will help in precise detection of the primary and secondary vertices to ensure robust selections and improve the trigger performance. FTK exploits hardware technologies with massive parallelism, combining Associative Memory ASICs, FPGAs and high-speed communication links.
A fast method for optical simulation of flood maps of light-sharing detector modules.
Shi, Han; Du, Dong; Xu, JianFeng; Moses, William W; Peng, Qiyu
2015-12-01
Optical simulation of the detector module level is highly desired for Position Emission Tomography (PET) system design. Commonly used simulation toolkits such as GATE are not efficient in the optical simulation of detector modules with complicated light-sharing configurations, where a vast amount of photons need to be tracked. We present a fast approach based on a simplified specular reflectance model and a structured light-tracking algorithm to speed up the photon tracking in detector modules constructed with polished finish and specular reflector materials. We simulated conventional block detector designs with different slotted light guide patterns using the new approach and compared the outcomes with those from GATE simulations. While the two approaches generated comparable flood maps, the new approach was more than 200-600 times faster. The new approach has also been validated by constructing a prototype detector and comparing the simulated flood map with the experimental flood map. The experimental flood map has nearly uniformly distributed spots similar to those in the simulated flood map. In conclusion, the new approach provides a fast and reliable simulation tool for assisting in the development of light-sharing-based detector modules with a polished surface finish and using specular reflector materials.
Scardino, Marco; D'Amato, Tiziana; Martorelli, Federica; Fenocchio, Giorgia; Simili, Vincenzo; Di Matteo, Berardo; Bugada, Dario; Kon, Elizaveta
2018-03-20
Currently many TKA protocols rely on multimodal analgesic protocols with patient-controlled analgesia systems that administer opioids through a patient controlled IV infusion pump, in addition to concomitant peripheral nerve blocks and local anesthetics. Although effective, PCA IV opioids do not provide optimal results with fast track rehabilitation protocols. The present is a retrospective study comparing the novel sublingual sufentanil PCA system (SSTS) to our standard of care foreseeing continuous femoral nerve block (cFNB) within a multimodal analgesic in a TKA fast-track protocol. The study evaluated 95 patients on SSTS (SSTS group) and 87 on cFNB (cFNB/control group) and collected data on numeric rating scores for pain from day 1-3 after surgery (T1, T2, T3), both at rest (NRS) and during movement (mNRS), patient's ability to walk, need for supplementary analgesia (rescue dose), occurrence of adverse effects, length of hospital stay, and usability rating for SSTS by both patients and hospital staff. NRS at rest was lower in the cFNB than in the SSTS group for all 3 days after surgery, whereas mNRS scores were lower in the SSTS group at all time points measured. Adverse effects were significantly fewer among patients of the SSTS group (6% patients) than those of the cFNB (74% patients) (p < 0.001). Rescue doses were needed by 5% of SSTS patients vs 60% of cFNB. The fewer adverse events and lower pain scores for the SSTS group were associated to a notably better ability to ambulate, with all patients (100%) of the SSTS group being able to stand and walk for 10 m from T1 on; patients in the cFNB group showed a slower recovery with only 40% being able to stand and walk on T1, 70% on T2 and 85% on T3. All patients of the SSTS group had a length of stay of 4 days (day of surgery plus 3 after) as foreseen by the fast track protocol, in comparison only 36% of cFNB. Lastly, patient and nursing staff judged SSTS easy to use. Our experience suggests that SSTS is a valuable strategy for routine postoperative analgesia following TKA in the context of a multimodal analgesic approach within the fast-track setting.
Evaluation of a Chlamydia trachomatis-specific, commercial, real-time PCR for use with ocular swabs.
Pickering, Harry; Holland, Martin J; Last, Anna R; Burton, Matthew J; Burr, Sarah E
2018-02-20
Trachoma, the leading infectious cause of blindness worldwide, is caused by conjunctival Chlamydia trachomatis infection. Trachoma is diagnosed clinically by observation of conjunctival inflammation and/or scarring; however, there is evidence that monitoring C. trachomatis infection may be required for elimination programmes. There are many commercial and 'in-house' nucleic acid amplification tests for the detection of C. trachomatis DNA, but the majority have not been validated for use with ocular swabs. This study evaluated a commercial assay, the Fast-Track Vaginal swab kit, using conjunctival samples from trachoma-endemic areas. An objective, biostatistical-based method for binary classification of continuous PCR data was developed, to limit potential user-bias in diagnostic settings. The Fast-Track Vaginal swab assay was run on 210 ocular swab samples from Guinea-Bissau and Tanzania. Fit of individual amplification curves to exponential or sigmoid models, derivative and second derivative of the curves and final fluorescence value were examined for utility in thresholding for determining positivity. The results from the Fast-Track Vaginal swab assay were evaluated against a commercial test (Amplicor CT/NG) and a non-commercial test (in-house droplet digital PCR), both of whose performance has previously been evaluated. Significant evidence of exponential amplification (R 2 > 0.99) and final fluorescence > 0.15 were combined for thresholding. This objective approach identified a population of positive samples, however there were a subset of samples that amplified towards the end of the cycling protocol (at or later than 35 cycles), which were less clearly defined. The Fast-Track Vaginal swab assay showed good sensitivity against the commercial (95.71) and non-commercial (97.18) tests. Specificity was lower against both (90.00 and 96.55, respectively). This study defined a simple, automated protocol for binary classification of continuous, real-time qPCR data, for use in an end-point diagnostic test. This method identified a population of positive samples, however, as with manual thresholding, a subset of samples that amplified towards the end of the cycling program were less easily classified. When used with ocular swabs, the Fast-Track Vaginal swab assay had good sensitivity for C. trachomatis detection, but lower specificity than the commercial and non-commercial assays it was evaluated against, possibly leading to false positives.
Fast Food Consumption and Gestational Diabetes Incidence in the SUN Project
Dominguez, Ligia J.; Martínez-González, Miguel A.; Basterra-Gortari, Francisco Javier; Gea, Alfredo; Barbagallo, Mario; Bes-Rastrollo, Maira
2014-01-01
Background Gestational diabetes prevalence is increasing, mostly because obesity among women of reproductive age is continuously escalating. We aimed to investigate the incidence of gestational diabetes according to the consumption of fast food in a cohort of university graduates. Methods The prospective dynamic “Seguimiento Universidad de Navarra” (SUN) cohort included data of 3,048 women initially free of diabetes or previous gestational diabetes who reported at least one pregnancy between December 1999 and March 2011. Fast food consumption was assessed through a validated 136-item semi-quantitative food frequency questionnaire. Fast food was defined as the consumption of hamburgers, sausages, and pizza. Three categories of fast food were established: low (0–3 servings/month), intermediate (>3 servings/month and ≤2 servings/week) and high (>2 servings/week). Non-conditional logistic regression models were used to adjust for potential confounders. Results We identified 159 incident cases of gestational diabetes during follow-up. After adjusting for age, baseline body mass index, total energy intake, smoking, physical activity, family history of diabetes, cardiovascular disease/hypertension at baseline, parity, adherence to Mediterranean dietary pattern, alcohol intake, fiber intake, and sugar-sweetened soft drinks consumption, fast food consumption was significantly associated with a higher risk of incident gestational diabetes, with multivariate adjusted OR of 1.31 (95% conficence interval [CI]:0.81–2.13) and 1.86 (95% CI: 1.13–3.06) for the intermediate and high categories, respectively, versus the lowest category of baseline fast food consumption (p for linear trend: 0.007). Conclusion Our results suggest that pre-pregnancy higher consumption of fast food is an independent risk factor for gestational diabetes. PMID:25215961
NASA Astrophysics Data System (ADS)
Kurzeck, Bernhard; Heckmann, Andreas; Wesseler, Christoph; Rapp, Matthias
2014-05-01
Future high-speed trains are the main focus of the DLR research project Next Generation Train. One central point of the research activities is the development of mechatronic track guidance for the two-axle intermediate wagons with steerable, individually powered, independently rotating wheels. The traction motors hereby fulfil two functions; they concurrently are traction drives and steering actuators. In this paper, the influence of the track properties - line layout and track irregularities - on the performance requirements for the guidance actuator is investigated using multi-body models in SIMPACK®. In order to compromise on the design conflict between low wheel wear and low steering torque, the control parameters of the mechatronic track guidance are optimised using the DLR in-house software MOPS. Besides the track irregularities especially the increasing inclination at transition curves defines high actuator requirements due to gyroscopic effects at high speed. After introducing a limiter for the actuating variables into the control system, a good performance is achieved.
Torres, Jaume; Svistunenko, Dimitri; Karlsson, Bo; Cooper, Chris E; Wilson, Michael T
2002-02-13
The rapid reduction of one of the copper atoms (type 2) of tree laccase by nitric oxide (NO) has been detected. Addition of NO to native laccase in the presence of oxygen leads to EPR changes consistent with fast reduction and slow reoxidation of this metal center. These events are paralleled by optical changes that are reminiscent of formation and decay of the peroxide intermediate in a fraction of the enzyme population. Formation of this species is only possible if the trinuclear copper cluster (type 2 plus type 3) is fully reduced. This condition can only be met if, as suggested previously, a fraction of the enzyme contains both type 3 coppers already reduced before addition of NO. Our data are consistent with this assumption. We have suggested recently that fast reduction of copper is the mechanism by which NO interacts with the oxidized dinuclear center in cytochrome c oxidase. The present experiments using laccase strongly support this view and suggest this reaction as a general mechanism by which copper proteins interact with NO. In addition, this provides an unexploited way to produce a stable peroxide intermediate in copper oxidases in which the full complement of copper atoms is present. This enables the O-O scission step in the catalytic cycle to be studied by electron addition to the peroxide derivative through the native electron entry site, type 1 copper.
NASA Astrophysics Data System (ADS)
Sutcliffe, G. D.; Milanese, L. M.; Orozco, D.; Lahmann, B.; Gatu Johnson, M.; Séguin, F. H.; Sio, H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D.; Park, H.-S.; Rygg, J. R.; Casey, D. T.; Bionta, R.; Turnbull, D. P.; Huntington, C. M.; Ross, J. S.; Zylstra, A. B.; Rosenberg, M. J.; Glebov, V. Yu.
2016-11-01
CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.
Sutcliffe, G D; Milanese, L M; Orozco, D; Lahmann, B; Gatu Johnson, M; Séguin, F H; Sio, H; Frenje, J A; Li, C K; Petrasso, R D; Park, H-S; Rygg, J R; Casey, D T; Bionta, R; Turnbull, D P; Huntington, C M; Ross, J S; Zylstra, A B; Rosenberg, M J; Glebov, V Yu
2016-11-01
CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.
Leis, S.A.; Engle, David M.; Leslie, David M.; Fehmi, J.S.
2005-01-01
Loss of grassland species resulting from activities such as off-road vehicle use increases the need for models that predict effects of anthropogenic disturbance. The relationship of disturbance by military training to plant species richness and composition on two soils (Foard and Lawton) in a mixed prairie area was investigated. Track cover (cover of vehicle disturbance to the soil) and soil organic carbon were selected as measures of short- and long-term disturbance, respectively. Soil and vegetation data, collected in 1-m 2 quadrats, were analyzed at three spatial scales (60, 10, and 1 m2). Plant species richness peaked at intermediate levels of soil organic carbon at the 10-m2 and 1-m2 spatial scales on both the Lawton and Foard soils, and at intermediate levels of track cover at all three spatial scales on the Foard soil. Species composition differed across the disturbance gradient on the Foard soil but not on the Lawton soil. Disturbance increased total plant species richness on the Foard soil. The authors conclude that disturbance up to intermediate levels can be used to maintain biodiversity by enriching the plant species pool. ?? 2005 Springer Science+Business Media, Inc.
Surveillance of Space - Optimal Use of Complementary Sensors for Maximum Efficiency
2006-04-01
as track - before - detect [4] have been shown to allow improved sensitivity. This technique employs fast running algorithms and computing power to pre...Multifunction Radar” IEEE Signal Processing Magazine, January 2006. [4] Wallace W R “The Use of Track - Before - Detect in Pulse-Doppler Radar” IEE 490, Radar
Leadership in Australian Rural Schools: Bush Track, Fast Track
ERIC Educational Resources Information Center
Graham, Lorraine; Paterson, David; Miller, Judith
2008-01-01
Due to the difficulties inherent in staffing rural schools it is increasingly common for beginning teachers to fill school leadership roles early in their careers. The accelerated progression of some teachers impacts on the overall nature of leadership in rural schools and creates unique pathways, generally different from those available to…
Why Graduate Students Reject the Fast Track
ERIC Educational Resources Information Center
Mason, Mary Ann; Goulden, Marc; Frasch, Karie
2009-01-01
The authors recently completed an unparalleled survey, with more than eight thousand doctoral student respondents across the University of California system, and what they heard is worrisome: major research universities may be losing some of the most talented tenure-track academics before they even arrive. In the eyes of many doctoral students,…
Fast regional readout CMOS Image Sensor for dynamic MLC tracking
NASA Astrophysics Data System (ADS)
Zin, H.; Harris, E.; Osmond, J.; Evans, P.
2014-03-01
Advanced radiotherapy techniques such as volumetric modulated arc therapy (VMAT) require verification of the complex beam delivery including tracking of multileaf collimators (MLC) and monitoring the dose rate. This work explores the feasibility of a prototype Complementary metal-oxide semiconductor Image Sensor (CIS) for tracking these complex treatments by utilising fast, region of interest (ROI) read out functionality. An automatic edge tracking algorithm was used to locate the MLC leaves edges moving at various speeds (from a moving triangle field shape) and imaged with various sensor frame rates. The CIS demonstrates successful edge detection of the dynamic MLC motion within accuracy of 1.0 mm. This demonstrates the feasibility of the sensor to verify treatment delivery involving dynamic MLC up to ~400 frames per second (equivalent to the linac pulse rate), which is superior to any current techniques such as using electronic portal imaging devices (EPID). CIS provides the basis to an essential real-time verification tool, useful in accessing accurate delivery of complex high energy radiation to the tumour and ultimately to achieve better cure rates for cancer patients.
Status of the geopotential. [earth gravity measurement
NASA Technical Reports Server (NTRS)
Lerch, F. J.
1983-01-01
Satellite laser ranging, satellite altimetry, and improved measurements of surface gravitational anomalies have broadened the data base on intermediate and short wavelength regions of the earth gravity field. The global data set served to develop new geopotential models with a resolution in spherical harmonics out to degree 180. The resolution was made possible using Seasat altimetry data containing 56,761 values of 1 x 1 deg gravity anomalies. Satellite-to-satellite tracking techniques involving the Geos-3 and Apollo spacecraft data for the sea surface temperature have yielded accurate intermediate wavelength gravity variations which correlate well with residual depth anomalies. Oceanic gravity anomalies have been computed directly from satellite altimetry or through statistical estimation using oceanic geoid heights. The data sets for gravimetric geoids have been compared with altimetric surfaces to identify areas which were of interest for geophysical investigation. Future data sets could become available from a proposed satellite-to-satellite Doppler tracking system (Gravsat) launched by NASA.
Detection of Ballast Damage by In-Situ Vibration Measurement of Sleepers
NASA Astrophysics Data System (ADS)
Lam, H. F.; Wong, M. T.; Keefe, R. M.
2010-05-01
Ballasted track is one of the most important elements of railway transportation systems worldwide. Owing to its importance in railway safety, many monitoring and evaluation methods have been developed. Current railway track monitoring systems are comprehensive, fast and efficient in testing railway track level and alignment, rail gauge, rail corrugation, etc. However, the monitoring of ballast condition still relies very much on visual inspection and core tests. Although extensive research has been carried out in the development of non-destructive methods for ballast condition evaluation, a commonly accepted and cost-effective method is still in demand. In Hong Kong practice, if abnormal train vibration is reported by the train operator or passengers, permanent way inspectors will locate the problem area by track geometry measurement. It must be pointed out that visual inspection can only identify ballast damage on the track surface, the track geometry deficiencies and rail twists can be detected using a track gauge. Ballast damage under the sleeper loading area and the ballast shoulder, which are the main factors affecting track stability and ride quality, are extremely difficult if not impossible to be detected by visual inspection. Core test is a destructive test, which is expensive, time consuming and may be disruptive to traffic. A fast real-time ballast damage detection method that can be implemented by permanent way inspectors with simple equipment can certainly provide valuable information for engineers in assessing the safety and riding quality of ballasted track systems. The main objective of this paper is to study the feasibility in using the vibration characteristics of sleepers in quantifying the ballast condition under the sleepers, and so as to explore the possibility in developing a handy method for the detection of ballast damage based on the measured vibration of sleepers.
How Does the Fast Track Intervention Prevent Adverse Outcomes in Young Adulthood?
Sorensen, Lucy C.; Dodge, Kenneth A.
2015-01-01
Numerous studies have shown that childhood interventions can foster improved outcomes in adulthood. Less well understood is precisely how – that is, through which developmental pathways – these interventions work. This study assesses mechanisms by which the Fast Track project (n=891), a randomized intervention in the early 1990s for high-risk children in four communities (Durham, NC; Nashville, TN; rural PA; and Seattle, WA), reduced delinquency, arrests, and health and mental health service utilization in adolescence through young adulthood (ages 12–20). A decomposition of treatment effects indicates that about a third of Fast Track’s impact on later crime outcomes can be accounted for by improvements in social and self-regulation skills during childhood (ages 6–11), such as prosocial behavior, emotion regulation and problem solving. These skills proved less valuable for the prevention of mental and physical health problems. PMID:26670938
Park, J H; Garipov, G K; Jeon, J A; Khrenov, B A; Kim, J E; Kim, M; Kim, Y K; Lee, C-H; Lee, J; Na, G W; Nam, S; Park, I H; Park, Y-S
2008-12-08
We introduce a novel telescope consisting of a pinhole-like camera with rotatable MEMS micromirrors substituting for pinholes. The design is ideal for observations of transient luminous phenomena or fast-moving objects, such as upper atmospheric lightning and bright gamma ray bursts. The advantage of the MEMS "obscura telescope" over conventional cameras is that it is capable both of searching for events over a wide field of view, and fast zooming to allow detailed investigation of the structure of events. It is also able to track the triggering object to investigate its space-time development, and to center the interesting portion of the image on the photodetector array. We present the proposed system and the test results for the MEMS obscura telescope which has a field of view of 11.3 degrees, sixteen times zoom-in and tracking within 1 ms. (c) 2008 Optical Society of America
The research on the mean shift algorithm for target tracking
NASA Astrophysics Data System (ADS)
CAO, Honghong
2017-06-01
The traditional mean shift algorithm for target tracking is effective and high real-time, but there still are some shortcomings. The traditional mean shift algorithm is easy to fall into local optimum in the tracking process, the effectiveness of the method is weak when the object is moving fast. And the size of the tracking window never changes, the method will fail when the size of the moving object changes, as a result, we come up with a new method. We use particle swarm optimization algorithm to optimize the mean shift algorithm for target tracking, Meanwhile, SIFT (scale-invariant feature transform) and affine transformation make the size of tracking window adaptive. At last, we evaluate the method by comparing experiments. Experimental result indicates that the proposed method can effectively track the object and the size of the tracking window changes.
Dynamics of a Landau-Zener non-dissipative system with fluctuating energy levels
NASA Astrophysics Data System (ADS)
Fai, L. C.; Diffo, J. T.; Ateuafack, M. E.; Tchoffo, M.; Fouokeng, G. C.
2014-12-01
This paper considers a Landau-Zener (two-level) system influenced by a three-dimensional Gaussian and non-Gaussian coloured noise and finds a general form of the time dependent diabatic quantum bit (qubit) flip transition probabilities in the fast, intermediate and slow noise limits. The qubit flip probability is observed to mimic (for low-frequencies noise) that of the standard LZ problem. The qubit flip probability is also observed to be the measure of quantum coherence of states. The transition probability is observed to be tailored by non-Gaussian low-frequency noise and otherwise by Gaussian low-frequency coloured noise. Intermediate and fast noise limits are observed to alter the memory of the system in time and found to improve and control quantum information processing.
Fast calibration of electromagnetically tracked oblique-viewing rigid endoscopes.
Liu, Xinyang; Rice, Christina E; Shekhar, Raj
2017-10-01
The oblique-viewing (i.e., angled) rigid endoscope is a commonly used tool in conventional endoscopic surgeries. The relative rotation between its two moveable parts, the telescope and the camera head, creates a rotation offset between the actual and the projection of an object in the camera image. A calibration method tailored to compensate such offset is needed. We developed a fast calibration method for oblique-viewing rigid endoscopes suitable for clinical use. In contrast to prior approaches based on optical tracking, we used electromagnetic (EM) tracking as the external tracking hardware to improve compactness and practicality. Two EM sensors were mounted on the telescope and the camera head, respectively, with considerations to minimize EM tracking errors. Single-image calibration was incorporated into the method, and a sterilizable plate, laser-marked with the calibration pattern, was also developed. Furthermore, we proposed a general algorithm to estimate the rotation center in the camera image. Formulas for updating the camera matrix in terms of clockwise and counterclockwise rotations were also developed. The proposed calibration method was validated using a conventional [Formula: see text], 5-mm laparoscope. Freehand calibrations were performed using the proposed method, and the calibration time averaged 2 min and 8 s. The calibration accuracy was evaluated in a simulated clinical setting with several surgical tools present in the magnetic field of EM tracking. The root-mean-square re-projection error averaged 4.9 pixel (range 2.4-8.5 pixel, with image resolution of [Formula: see text] for rotation angles ranged from [Formula: see text] to [Formula: see text]. We developed a method for fast and accurate calibration of oblique-viewing rigid endoscopes. The method was also designed to be performed in the operating room and will therefore support clinical translation of many emerging endoscopic computer-assisted surgical systems.
SU-F-T-370: A Fast Monte Carlo Dose Engine for Gamma Knife
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, T; Zhou, L; Li, Y
2016-06-15
Purpose: To develop a fast Monte Carlo dose calculation algorithm for Gamma Knife. Methods: To make the simulation more efficient, we implemented the track repeating technique on GPU. We first use EGSnrc to pre-calculate the photon and secondary electron tracks in water from two mono-energy photons of 60Co. The total photon mean free paths for different materials and energies are obtained from NIST. During simulation, each entire photon track was first loaded to shared memory for each block, the incident original photon was then splitted to Nthread sub-photons, each thread transport one sub-photon, the Russian roulette technique was applied formore » scattered and bremsstrahlung photons. The resultant electrons from photon interactions are simulated by repeating the recorded electron tracks. The electron step length is stretched/shrunk proportionally based on the local density and stopping power ratios of the local material. Energy deposition in a voxel is proportional to the fraction of the equivalent step length in that voxel. To evaluate its accuracy, dose deposition in a 300mm*300mm*300mm water phantom is calculated, and compared to EGSnrc results. Results: Both PDD and OAR showed great agreements (within 0.5%) between our dose engine result and the EGSnrc result. It only takes less than 1 min for every simulation, being reduced up to ∼40 times compared to EGSnrc simulations. Conclusion: We have successfully developed a fast Monte Carlo dose engine for Gamma Knife.« less
Scalable Track Detection in SAR CCD Images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chow, James G; Quach, Tu-Thach
Existing methods to detect vehicle tracks in coherent change detection images, a product of combining two synthetic aperture radar images ta ken at different times of the same scene, rely on simple, fast models to label track pixels. These models, however, are often too simple to capture natural track features such as continuity and parallelism. We present a simple convolutional network architecture consisting of a series of 3-by-3 convolutions to detect tracks. The network is trained end-to-end to learn natural track features entirely from data. The network is computationally efficient and improves the F-score on a standard dataset to 0.988,more » up fr om 0.907 obtained by the current state-of-the-art method.« less
Barreira, Tiago V; Harrington, Deirdre M; Katzmarzyk, Peter T
2014-01-01
To determine whether relationships exist between accelerometer-measured moderate-to-vigorous physical activity (MVPA) and other cardiovascular (CV) health metrics in a large sample. Data from the 2003-2006 National Health and Nutrition Examination Survey (NHANES) collected from January 1, 2003, through December 31, 2006, were used. Overall, 3454 nonpregnant adults 20 years or older who fasted for 6 hours or longer, with valid accelerometer data and with CV health metrics, were included in the study. Blood pressure (BP), body mass index (BMI), smoking status, diet, fasting plasma glucose level, and total cholesterol level were defined as ideal, intermediate, and poor on the basis of American Heart Association criteria. Results were weighted to account for sampling design, oversampling, and nonresponse. Significant increasing linear trends in mean daily MVPA were observed across CV health levels for BMI, BP, and fasting plasma glucose (P<.001). Those with a poor BMI and BP had significantly lower mean daily MVPA than those with intermediate and ideal BMIs and BPs (all P<.001). In addition, individuals with an intermediate fasting plasma glucose level had significantly lower mean daily MVPA than individuals at the ideal levels (P<.001). No significant linear trends were observed for cholesterol, smoking, and diet. A significant linear trend was observed for mean daily MVPA and the overall number of other CV health metrics (P<.001). Objectively measured MVPA was related to other CV health metrics in this large sample. These results support the inclusion of physical activity in the overall definition of ideal CV health. Copyright © 2014 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Shen, L Y; Luo, J; Lei, H G; Jiang, Y Z; Bai, L; Li, M Z; Tang, G Q; Li, X W; Zhang, S H; Zhu, L
2015-11-13
The myosin heavy chain (MyHC) composition, glycolytic potential, mitochondrial content, and gene expression related to energy metabolism were analyzed in eight muscles from Tibetan pigs, to study how meat quality develops in different muscle tissues. The muscles were classified into three clusters, based on MyHC composition: masseter, trapezius, and latissimus dorsi as 'slow-oxidative-type'; psoas major and semimembranosus as 'intermediate-type'; and longissimus dorsi, obliquus externus abdominis, and semitendinosus as 'fast-glycolytic-type'. The 'slow-oxidative-type' muscles had the highest MyHC I and MyHC IIA content (P < 0.01); 'intermediate-type' muscles, the highest MyHC IIx content (P < 0.01); and 'fast-glycolytic-type' muscles, the highest MyHC IIb content (P < 0.01). The pH values measured in 'slow-oxidative-type' muscles were higher than those in the other clusters were; however, the color of 'fast-glycolytic-type' muscles was palest (P < 0.01). Mitochondrial content increased in the order: fast-glycolytic-type < intermediate-type < slow-oxidative-type. In the 'slow-oxidative-type' muscles, the expression levels of genes related to ATP synthesis were higher, but were lower for those related to glycogen synthesis and glycolysis. Mitochondrial content was significantly positively correlated with MyHC I content, but negatively correlated with MyHC IIb content. MyHC I and mitochondrial content were both negatively correlated with glycolytic potential. Overall, muscles used frequently in exercise had a higher proportion of type I fibers. 'Slow-oxidative-type' muscles, rich in type I fibers with higher mitochondrial and lower glycogen and glucose contents, had a higher ATP synthesis efficiency and lower glycolytic capacity, which contributed to their superior meat quality.
Age Spreads and the Temperature Dependence of Age Estimates in Upper Sco
NASA Astrophysics Data System (ADS)
Fang, Qiliang; Herczeg, Gregory J.; Rizzuto, Aaron
2017-06-01
Past estimates for the age of the Upper Sco Association are typically 11–13 Myr for intermediate-mass stars and 4–5 Myr for low-mass stars. In this study, we simulate populations of young stars to investigate whether this apparent dependence of estimated age on spectral type may be explained by the star formation history of the association. Solar and intermediate mass stars begin their pre-main sequence evolution on the Hayashi track, with fully convective interiors and cool photospheres. Intermediate-mass stars quickly heat up and transition onto the radiative Henyey track. As a consequence, for clusters in which star formation occurs on a timescale similar to that of the transition from a convective to a radiative interior, discrepancies in ages will arise when ages are calculated as a function of temperature instead of mass. Simple simulations of a cluster with constant star formation over several Myr may explain about half of the difference in inferred ages versus photospheric temperature; speculative constructions that consist of a constant star formation followed by a large supernova-driven burst could fully explain the differences, including those between F and G stars where evolutionary tracks may be more accurate. The age spreads of low-mass stars predicted from these prescriptions for star formation are consistent with the observed luminosity spread of Upper Sco. The conclusion that a lengthy star formation history will yield a temperature dependence in ages is expected from the basic physics of pre-main sequence evolution, and is qualitatively robust to the large uncertainties in pre-main sequence evolutionary models.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fang Qiliang; Herczeg, Gregory J.; Rizzuto, Aaron
Past estimates for the age of the Upper Sco Association are typically 11–13 Myr for intermediate-mass stars and 4–5 Myr for low-mass stars. In this study, we simulate populations of young stars to investigate whether this apparent dependence of estimated age on spectral type may be explained by the star formation history of the association. Solar and intermediate mass stars begin their pre-main sequence evolution on the Hayashi track, with fully convective interiors and cool photospheres. Intermediate-mass stars quickly heat up and transition onto the radiative Henyey track. As a consequence, for clusters in which star formation occurs on amore » timescale similar to that of the transition from a convective to a radiative interior, discrepancies in ages will arise when ages are calculated as a function of temperature instead of mass. Simple simulations of a cluster with constant star formation over several Myr may explain about half of the difference in inferred ages versus photospheric temperature; speculative constructions that consist of a constant star formation followed by a large supernova-driven burst could fully explain the differences, including those between F and G stars where evolutionary tracks may be more accurate. The age spreads of low-mass stars predicted from these prescriptions for star formation are consistent with the observed luminosity spread of Upper Sco. The conclusion that a lengthy star formation history will yield a temperature dependence in ages is expected from the basic physics of pre-main sequence evolution, and is qualitatively robust to the large uncertainties in pre-main sequence evolutionary models.« less
A method to harness global crowd-sourced data to understand travel behavior in avalanche terrain.
NASA Astrophysics Data System (ADS)
Hendrikx, J.; Johnson, J.
2015-12-01
To date, most studies of the human dimensions of decision making in avalanche terrain has focused on two areas - post-accident analysis using accident reports/interviews and, the development of tools as decision forcing aids. We present an alternate method using crowd-sourced citizen science, for understanding decision-making in avalanche terrain. Our project combines real-time GPS tracking via a smartphone application, with internet based surveys of winter backcountry users as a method to describe and quantify travel practices in concert with group decision-making dynamics, and demographic data of participants during excursions. Effectively, we use the recorded GPS track taken within the landscape as an expression of the decision making processes and terrain usage by the group. Preliminary data analysis shows that individual experience levels, gender, avalanche hazard, and group composition all influence the ways in which people travel in avalanche terrain. Our results provide the first analysis of coupled real-time GPS tracking of the crowd while moving in avalanche terrain combined with psychographic and demographic correlates. This research will lead to an improved understanding of real-time decision making in avalanche terrain. In this paper we will specifically focus on the presentation of the methods used to solicit, and then harness the crowd to obtain data in a unique and innovative application of citizen science where the movements within the terrain are the desired output data (Figure 1). Figure 1: Example GPS tracks sourced from backcountry winter users in the Teton Pass area (Wyoming), from the 2014-15 winter season, where tracks in red represent those recorded as self-assessed experts (as per our survey), and where tracks in blue represent those recorded as self-assessed intermediates. All tracks shown were obtained under similar avalanche conditions. Statistical analysis of terrain metrics showed that the experts used steeper terrain than the intermediate users under similar avalanche conditions, demonstrating different terrain choice and use as a function of experience rather than hazard level.
A Fast and Accurate Method of Radiation Hydrodynamics Calculation in Spherical Symmetry
NASA Astrophysics Data System (ADS)
Stamer, Torsten; Inutsuka, Shu-ichiro
2018-06-01
We develop a new numerical scheme for solving the radiative transfer equation in a spherically symmetric system. This scheme does not rely on any kind of diffusion approximation, and it is accurate for optically thin, thick, and intermediate systems. In the limit of a homogeneously distributed extinction coefficient, our method is very accurate and exceptionally fast. We combine this fast method with a slower but more generally applicable method to describe realistic problems. We perform various test calculations, including a simplified protostellar collapse simulation. We also discuss possible future improvements.
Is "Teach for All" Knocking on Your Door?
ERIC Educational Resources Information Center
Price, Anne; McConney, Andrew
2013-01-01
Over the past few decades there has been a rapid expansion in alternative "fast track" routes for teacher preparation. Among the most aggressive of these are Teach for All (TFA) schemes characterized not only by their ultra fast entry to teaching (6-7 week course) but also by their underlying philosophy that the so called…
The High-Potential Fast-Flying Achiever: Themes from the English Language Literature 1976-1995.
ERIC Educational Resources Information Center
Altman, Yochanan
1997-01-01
Review of business management literature from the United States, United Kingdom, and Canada identified the following: the images of high flyer, fast track, and high achiever; the meaning of success; emphasis on performance; corporate rites of passage; and opportunities for women to be high flyers. (SK)
Fast-track for fast times: catching and keeping generation Y in the nursing workforce.
Walker, Kim
2007-04-01
There is little doubt we find ourselves in challenging times as never before has there been such generational diversity in the nursing workforce. Currently, nurses from four distinct (and now well recognised and discussed) generational groups jostle for primacy of recognition and reward. Equally significant is the acute realisation that our ageing profession must find ways to sustain itself in the wake of huge attrition as the 'baby boomer' nurses start retiring over the next ten to fifteen years. These realities impel us to become ever more strategic in our thinking about how best to manage the workforce of the future. This paper presents two exciting and original innovations currently in train at one of Australia's leading Catholic health care providers: firstly, a new fast-track bachelor of nursing program for fee-paying domestic students. This is a collaborative venture between St Vincent's and Mater Health, Sydney (SV&MHS) and the University of Tasmania (UTas); as far as we know, it is unprecedented in Australia. As well, the two private facilities of SV&MHS, St Vincent's Private (SVPH) and the Mater Hospitals, have developed and implemented a unique 'accelerated progression pathway' (APP) to enable registered nurses with talent and ambition to fast track their career through a competency and merit based system of performance management and reward. Both these initiatives are aimed squarely at the gen Y demographic and provide potential to significantly augment our capacity to recruit and retain quality people well into the future.
An efficient and accurate 3D displacements tracking strategy for digital volume correlation
NASA Astrophysics Data System (ADS)
Pan, Bing; Wang, Bo; Wu, Dafang; Lubineau, Gilles
2014-07-01
Owing to its inherent computational complexity, practical implementation of digital volume correlation (DVC) for internal displacement and strain mapping faces important challenges in improving its computational efficiency. In this work, an efficient and accurate 3D displacement tracking strategy is proposed for fast DVC calculation. The efficiency advantage is achieved by using three improvements. First, to eliminate the need of updating Hessian matrix in each iteration, an efficient 3D inverse compositional Gauss-Newton (3D IC-GN) algorithm is introduced to replace existing forward additive algorithms for accurate sub-voxel displacement registration. Second, to ensure the 3D IC-GN algorithm that converges accurately and rapidly and avoid time-consuming integer-voxel displacement searching, a generalized reliability-guided displacement tracking strategy is designed to transfer accurate and complete initial guess of deformation for each calculation point from its computed neighbors. Third, to avoid the repeated computation of sub-voxel intensity interpolation coefficients, an interpolation coefficient lookup table is established for tricubic interpolation. The computational complexity of the proposed fast DVC and the existing typical DVC algorithms are first analyzed quantitatively according to necessary arithmetic operations. Then, numerical tests are performed to verify the performance of the fast DVC algorithm in terms of measurement accuracy and computational efficiency. The experimental results indicate that, compared with the existing DVC algorithm, the presented fast DVC algorithm produces similar precision and slightly higher accuracy at a substantially reduced computational cost.
Human tracking in thermal images using adaptive particle filters with online random forest learning
NASA Astrophysics Data System (ADS)
Ko, Byoung Chul; Kwak, Joon-Young; Nam, Jae-Yeal
2013-11-01
This paper presents a fast and robust human tracking method to use in a moving long-wave infrared thermal camera under poor illumination with the existence of shadows and cluttered backgrounds. To improve the human tracking performance while minimizing the computation time, this study proposes an online learning of classifiers based on particle filters and combination of a local intensity distribution (LID) with oriented center-symmetric local binary patterns (OCS-LBP). Specifically, we design a real-time random forest (RF), which is the ensemble of decision trees for confidence estimation, and confidences of the RF are converted into a likelihood function of the target state. First, the target model is selected by the user and particles are sampled. Then, RFs are generated using the positive and negative examples with LID and OCS-LBP features by online learning. The learned RF classifiers are used to detect the most likely target position in the subsequent frame in the next stage. Then, the RFs are learned again by means of fast retraining with the tracked object and background appearance in the new frame. The proposed algorithm is successfully applied to various thermal videos as tests and its tracking performance is better than those of other methods.
A binary link tracker for the BaBar level 1 trigger system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berenyi, A.; Chen, H.K.; Dao, K.
1999-08-01
The BaBar detector at PEP-II will operate in a high-luminosity e{sup +}e{sup {minus}} collider environment near the {Upsilon}(4S) resonance with the primary goal of studying CP violation in the B meson system. In this environment, typical physics events of interest involve multiple charged particles. These events are identified by counting these tracks in a fast first level (Level 1) trigger system, by reconstructing the tracks in real time. For this purpose, a Binary Link Tracker Module (BLTM) was designed and fabricated for the BaBar Level 1 Drift Chamber trigger system. The BLTM is responsible for linking track segments, constructed bymore » the Track Segment Finder Modules (TSFM), into complete tracks. A single BLTM module processes a 360 MBytes/s stream of segment hit data, corresponding to information from the entire Drift Chamber, and implements a fast and robust algorithm that tolerates high hit occupancies as well as local inefficiencies of the Drift Chamber. The algorithms and the necessary control logic of the BLTM were implemented in Field Programmable Gate Arrays (FPGAs), using the VHDL hardware description language. The finished 9U x 400 mm Euro-format board contains roughly 75,000 gates of programmable logic or about 10,000 lines of VHDL code synthesized into five FPGAs.« less
Fast Track, Bush Track: Late Career Female Rural School Leaders Taking the Slow Road
ERIC Educational Resources Information Center
Miller, Judith; Graham, Lorraine; Al-Awiwe, Azhar
2014-01-01
Previous research related to this study explored early career female leaders' experiences in rural school settings, and probed the personal and professional challenges they faced and their motivations to accept formal and informal leadership roles ahead of the usual timeframes (e.g., Graham, Miller & Paterson, 2009). This study set out to…
ERIC Educational Resources Information Center
Howe, Quincy
2006-01-01
In this article, the author relates how a math-assessment software has allowed his school to track the academic progress of its students. The author relates that in the first year that the software was deployed, schoolwide averages in terms of national standing on the math ITBS rose from the 42nd to 59th percentile. In addition, a significant…
The Long Island Sound Dredged Material Containment Feasibility Study.
1983-02-01
ancilliary businesses, such as sporting goods stores, dockside gasoline dealers, bait and tackle shops, and fast food services would also be negatively...to there is almost always some ex- tached or unable to move fast enough maintain the area’s importance as a change of nutrients and organisms to avoid...basis, authorized depth of 14 feet or less will no longer be maintained by the Corps of (4) Fast -tracking of navigation Engineers. Presently, only 7
Phonological and Orthographic Overlap Effects in Fast and Masked Priming
Frisson, Steven; Bélanger, Nathalie N.; Rayner, Keith
2014-01-01
We investigated how orthographic and phonological information is activated during reading, using a fast priming task, and during single word recognition, using masked priming. Specifically, different types of overlap between prime and target were contrasted: high orthographic and high phonological overlap (track-crack), high orthographic and low phonological overlap (bear-gear), or low orthographic and high phonological overlap (fruit-chute). In addition, we examined whether (orthographic) beginning overlap (swoop-swoon) yielded the same priming pattern as end (rhyme) overlap (track-crack). Prime durations were 32 and 50ms in the fast priming version, and 50ms in the masked priming version, and mode of presentation (prime and target in lower case) was identical. The fast priming experiment showed facilitatory priming effects when both orthography and phonology overlapped, with no apparent differences between beginning and end overlap pairs. Facilitation was also found when prime and target only overlapped orthographically. In contrast, the masked priming experiment showed inhibition for both types of end overlap pairs (with and without phonological overlap), and no difference for begin overlap items. When prime and target only shared principally phonological information, facilitation was only found with a long prime duration in the fast priming experiment, while no differences were found in the masked priming version. These contrasting results suggest that fast priming and masked priming do not necessarily tap into the same type of processing. PMID:24365065
NASA Astrophysics Data System (ADS)
Hosokawa, Shinya; Pilgrim, Wolf-Christian; Höhle, Astrid; Szubrin, Daniel; Boudet, Nathalie; Bérar, Jean-François; Maruyama, Kenji
2012-04-01
Laser-induced crystalline-amorphous phase change of Ge-Sb-Te alloys is the key mechanism enabling the fast and stable writing/erasing processes in rewritable optical storage devices, such as digital versatile disk (DVD) or blu-ray disk. Although the structural information in the amorphous phase is essential for clarifying this fast process, as well as long lasting stabilities of both the phases, experimental works were mostly limited to the short-range order by x ray absorption fine structure. Here we show both the short and intermediate-range atomic structures of amorphous DVD material, Ge2Sb2Te5 (GST), investigated by a combination of anomalous x ray scattering and reverse Monte Carlo modeling. From the obtained atomic configurations of amorphous GST, we have found that the Sb atoms and half of the Ge atoms play roles in the fast phase change process of order-disorder transition, while the remaining Ge atoms act for the proper activation energy of barriers between the amorphous and crystalline phases.
A fast method for optical simulation of flood maps of light-sharing detector modules
Shi, Han; Du, Dong; Xu, JianFeng; Moses, William W.; Peng, Qiyu
2016-01-01
Optical simulation of the detector module level is highly desired for Position Emission Tomography (PET) system design. Commonly used simulation toolkits such as GATE are not efficient in the optical simulation of detector modules with complicated light-sharing configurations, where a vast amount of photons need to be tracked. We present a fast approach based on a simplified specular reflectance model and a structured light-tracking algorithm to speed up the photon tracking in detector modules constructed with polished finish and specular reflector materials. We simulated conventional block detector designs with different slotted light guide patterns using the new approach and compared the outcomes with those from GATE simulations. While the two approaches generated comparable flood maps, the new approach was more than 200–600 times faster. The new approach has also been validated by constructing a prototype detector and comparing the simulated flood map with the experimental flood map. The experimental flood map has nearly uniformly distributed spots similar to those in the simulated flood map. In conclusion, the new approach provides a fast and reliable simulation tool for assisting in the development of light-sharing-based detector modules with a polished surface finish and using specular reflector materials. PMID:27660376
A fast method for optical simulation of flood maps of light-sharing detector modules
Shi, Han; Du, Dong; Xu, JianFeng; ...
2015-09-03
Optical simulation of the detector module level is highly desired for Position Emission Tomography (PET) system design. Commonly used simulation toolkits such as GATE are not efficient in the optical simulation of detector modules with complicated light-sharing configurations, where a vast amount of photons need to be tracked. Here, we present a fast approach based on a simplified specular reflectance model and a structured light-tracking algorithm to speed up the photon tracking in detector modules constructed with polished finish and specular reflector materials. We also simulated conventional block detector designs with different slotted light guide patterns using the new approachmore » and compared the outcomes with those from GATE simulations. And while the two approaches generated comparable flood maps, the new approach was more than 200–600 times faster. The new approach has also been validated by constructing a prototype detector and comparing the simulated flood map with the experimental flood map. The experimental flood map has nearly uniformly distributed spots similar to those in the simulated flood map. In conclusion, the new approach provides a fast and reliable simulation tool for assisting in the development of light-sharing-based detector modules with a polished surface finish and using specular reflector materials.« less
X-33 Environmental Impact Statement: A Fast Track Approach
NASA Technical Reports Server (NTRS)
McCaleb, Rebecca C.; Holland, Donna L.
1998-01-01
NASA is required by the National Environmental Policy Act (NEPA) to prepare an appropriate level environmental analysis for its major projects. Development of the X-33 Technology Demonstrator and its associated flight test program required an environmental impact statement (EIS) under the NEPA. The EIS process is consists of four parts: the "Notice of Intent" to prepare an EIS and scoping; the draft EIS which is distributed for review and comment; the final ETS; and the "Record of Decision." Completion of this process normally takes from 2 - 3 years, depending on the complexity of the proposed action. Many of the agency's newest fast track, technology demonstration programs require NEPA documentation, but cannot sustain the lengthy time requirement between program concept development to implementation. Marshall Space Flight Center, in cooperation with Kennedy Space Center, accomplished the NEPA process for the X-33 Program in 13 months from Notice of Intent to Record of Decision. In addition, the environmental team implemented an extensive public involvement process, conducting a total of 23 public meetings for scoping and draft EIS comment along with numerous informal meetings with public officials, civic organizations, and Native American Indians. This paper will discuss the fast track approach used to successfully accomplish the NEPA process for X-33 on time.
Ding, Yu; Li, Chunqiang
2016-01-01
Nanoscale particle tracking in three dimensions is crucial to directly observe dynamics of molecules and nanoparticles in living cells. Here we present a three-dimensional particle tracking method based on temporally focused two-photon excitation. Multiple particles are imaged at 30 frames/s in volume up to 180 × 180 × 100 µm3. The spatial localization precision can reach 50 nm. We demonstrate its capability of tracking fast swimming microbes at speed of ~200 µm/s. Two-photon dual-color tracking is achieved by simultaneously exciting two kinds of fluorescent beads at 800 nm to demonstrate its potential in molecular interaction studies. Our method provides a simple wide-field fluorescence imaging approach for deep multiple-particle tracking. PMID:27867724
Dehydration kinetics of talc and 10 Å phase: Consequences for subduction zone seismicity
NASA Astrophysics Data System (ADS)
Chollet, Mélanie; Daniel, Isabelle; Koga, Kenneth T.; Petitgirard, Sylvain; Morard, Guillaume
2009-06-01
The process of dehydration embrittlement is usually proposed as an explanation for the presence of intermediate-depth earthquakes in subduction zones. It assumes that the release of water by hydrous mineral breakdown is fast enough to provoke brittle failure. We performed high-pressure, high-temperature, dehydration experiments of talc and 10 Å phase coupled with in situ measurement of reaction kinetics using synchrotron X-ray diffraction. Newly developed, X-ray transparent, pressure-sealed, titanium capsule ensured a closed thermochemical environment. From isothermal kinetics data fitted to the Avrami's equation and from the texture of reaction products, we conclude that dehydration rates of these minerals are limited by diffusion. Predicted minimum rates of fluid release range from 10 - 4 to 9 × 10 - 6 m 3fluid m - 3 rock s - 1 , and are fast enough to provoke hydraulic rupture since Maxwell relaxation rate of rocks relevant of subduction zones are slower than the rate of fluid release. These rates are comparable between talc, 10 Å phase and antigorite also [Perrillat, J.-P., Daniel, I., Koga, K.T., Reynard, B., Cardon, H., Crichton, W.A., 2005. Kinetics of antigorite dehydration: a real-time X-ray diffraction study. Earth Planet. Sci. Lett. 236, 899-913]. Consequently, we suggest that the dehydration of hydrous minerals may eventually be fast enough to trigger the intermediate-depth earthquakes, and that the deepest among intermediate-depth earthquakes may actually locate the limits for dehydration of hydrous minerals in the downgoing lithosphere.
Oestergaard, Lisa G; Christensen, Finn B; Nielsen, Claus V; Bünger, Cody E; Fruensgaard, Soeren; Sogaard, Rikke
2013-11-01
Economic evaluation conducted alongside a randomized controlled trial with 1-year follow-up. To examine the cost-effectiveness of initiating rehabilitation 6 weeks after surgery as opposed to 12 weeks after surgery. In a previously reported randomized controlled trial, we assessed the impact of timing of rehabilitation after a lumbar spinal fusion and found that a fast-track strategy led to poorer functional ability. Before making recommendations, it seems relevant to address the societal perspective including return to work, quality of life, and costs. A cost-effectiveness analysis and a cost-utility analysis were conducted. Eighty-two patients undergoing instrumented lumbar spinal fusion due to degenerative disc disease or spondylolisthesis (grade I or II) were randomized to an identical protocol of 4 sessions of group-based rehabilitation and were instructed in home exercises focusing on active stability training. Outcome parameters included functional disability (Oswestry Disability Index) and quality-adjusted life years. Health care and productivity costs were estimated from national registries and reported in euros. Costs and effects were transformed into net benefit. Bootstrapping was used to estimate 95% confidence intervals (95% CI). The fast-track strategy tended to be costlier by €6869 (95% CI, -4640 to 18,378) while at the same time leading to significantly poorer outcomes of functional disability by -9 points (95% CI, -18 to -3) and a tendency for a reduced gain in quality-adjusted life years by -0.04 (95% CI, -0.13 to 0.01). The overall probability for the fast-track strategy being cost-effective does not reach 10% at conventional thresholds for cost-effectiveness. Initiating rehabilitation at 6 weeks as opposed to 12 weeks after surgery is on average more costly and less effective. The uncertainty of this result did not seem to be sensitive to methodological issues, and clinical managements who have already adapted fast-track rehabilitation strategies have reason to reconsider their choice. .
Quintana-Díaz, Manuel; Fabra-Cadenas, Sara; Gómez-Ramírez, Susana; Martínez-Virto, Ana; García-Erce, José A; Muñoz, Manuel
2016-03-01
Clinically significant anaemia, requiring red blood cell transfusions, is frequently observed in Emergency Departments (ED). To optimise blood product use, we developed a clinical protocol for the management of iron-deficiency anaemia in a fast-track anaemia clinic within the ED. From November 2010 to January 2014, patients presenting with sub-acute, moderate-to-severe anaemia (haemoglobin [Hb] <11 g/dL) and confirmed or suspected iron deficiency were referred to the fast-track anaemia clinic. Those with absolute or functional iron deficiency were given intravenous (IV) ferric carboxymaltose 500-1,000 mg/week and were reassessed 4 weeks after receiving the total iron dose. The primary study outcome was the haematological response (Hb≥12 g/dL and/or Hb increment ≥2 g/dL). Changes in blood and iron parameters, transfusion rates and IV iron-related adverse drug effects were secondary outcomes. Two hundred and two anaemic patients with iron deficiency (150 women/52 men; mean age, 64 years) were managed in the fast-track anaemia clinic, and received a median IV iron dose of 1,500 mg (1,000-2,000 mg). Gastro-intestinal (44%) or gynaecological (26%) bleeding was the most frequent cause of the anaemia. At follow-up (183 patients), the mean Hb increment was 3.9±2.2 g/dL; 84% of patients were classified as responders and blood and iron parameters normalised in 90%. During follow-up, 35 (17%) patients needed transfusions (2 [range: 1-3] units per patient) because they had low Hb levels, symptoms of anaemia and/or were at risk. Eight mild and one moderate, self-limited adverse drug effects were witnessed. Our data support the feasibility of a clinical protocol for management of sub-acute anaemia with IV iron in the ED. IV iron was efficacious, safe and well tolerated. Early management of anaemia will improve the use of blood products in the ED.
Description and performance of track and primary-vertex reconstruction with the CMS tracker
Chatrchyan, Serguei
2014-10-16
A description is provided of the software algorithms developed for the CMS tracker both for reconstructing charged-particle trajectories in proton-proton interactions and for using the resulting tracks to estimate the positions of the LHC luminous region and individual primary-interaction vertices. Despite the very hostile environment at the LHC, the performance obtained with these algorithms is found to be excellent. For tbar t events under typical 2011 pileup conditions, the average track-reconstruction efficiency for promptly-produced charged particles with transverse momenta of p T > 0.9GeV is 94% for pseudorapidities of |η| < 0.9 and 85% for 0.9 < |η| < 2.5.more » The inefficiency is caused mainly by hadrons that undergo nuclear interactions in the tracker material. For isolated muons, the corresponding efficiencies are essentially 100%. For isolated muons of p T = 100GeV emitted at |η| < 1.4, the resolutions are approximately 2.8% in p T, and respectively, 10μm and 30μm in the transverse and longitudinal impact parameters. The position resolution achieved for reconstructed primary vertices that correspond to interesting pp collisions is 10–12μm in each of the three spatial dimensions. The tracking and vertexing software is fast and flexible, and easily adaptable to other functions, such as fast tracking for the trigger, or dedicated tracking for electrons that takes into account bremsstrahlung.« less
NASA Astrophysics Data System (ADS)
Lipscombe, Trevor C.; Mungan, Carl E.
2018-05-01
The brachistochrone problem consists of finding the track of shortest travel time between given initial and final points for a particle sliding frictionlessly along it under the influence of a given external force field. Solvable variations of the standard example of a uniform gravitational field would be suitable for homework and computer projects by undergraduate physics students studying intermediate mechanics and electromagnetism. An electrobrachistochrone problem is here proposed, in which a charged particle moves along a frictionless track under the influence of its electrostatic force of attraction to an image charge in a grounded conducting plane below the track. The path of least time is found to be a foreshortened cycloid and its properties are investigated analytically and graphically.
Tracking Temporal Hazard in the Human Electroencephalogram Using a Forward Encoding Model
2018-01-01
Abstract Human observers automatically extract temporal contingencies from the environment and predict the onset of future events. Temporal predictions are modeled by the hazard function, which describes the instantaneous probability for an event to occur given it has not occurred yet. Here, we tackle the question of whether and how the human brain tracks continuous temporal hazard on a moment-to-moment basis, and how flexibly it adjusts to strictly implicit variations in the hazard function. We applied an encoding-model approach to human electroencephalographic data recorded during a pitch-discrimination task, in which we implicitly manipulated temporal predictability of the target tones by varying the interval between cue and target tone (i.e. the foreperiod). Critically, temporal predictability either was driven solely by the passage of time (resulting in a monotonic hazard function) or was modulated to increase at intermediate foreperiods (resulting in a modulated hazard function with a peak at the intermediate foreperiod). Forward-encoding models trained to predict the recorded EEG signal from different temporal hazard functions were able to distinguish between experimental conditions, showing that implicit variations of temporal hazard bear tractable signatures in the human electroencephalogram. Notably, this tracking signal was reconstructed best from the supplementary motor area, underlining this area’s link to cognitive processing of time. Our results underline the relevance of temporal hazard to cognitive processing and show that the predictive accuracy of the encoding-model approach can be utilized to track abstract time-resolved stimuli. PMID:29740594
Hybrid songbirds employ intermediate routes in a migratory divide.
Delmore, Kira E; Irwin, Darren E
2014-10-01
Migratory divides are contact zones between populations that use different routes to navigate around unsuitable areas on seasonal migration. Hybrids in divides have been predicted to employ intermediate and potentially inferior routes. We provide the first direct test of this hypothesis, using light-level geolocators to track birds breeding in a hybrid zone between Swainson's thrushes in western Canada. Compared to parental forms, hybrids exhibited increased variability in their migratory routes, with some using intermediate routes that crossed arid and mountainous regions, and some using the same routes as one parental group on fall migration and the other on spring migration. Hybrids also tended to use geographically intermediate wintering sites. Analysis of genetic variation across the hybrid zone suggests moderately strong selection against hybrids. These results indicate that seasonal migratory behaviour might be a source of selection against hybrids, supporting a possible role for migration in speciation. © 2014 John Wiley & Sons Ltd/CNRS.
Tracking Weight Change, Insulin Resistance, Stress, and Aerobic Fitness over 4 Years of College
ERIC Educational Resources Information Center
Hopper, Mari K.; Moninger, Shana Lynn
2017-01-01
Objective: To determine if weight gain is accompanied by development of insulin resistance (IR) during 4 years in college. Participants: Two cohorts of college students were enrolled in fall semesters 2009 and 2010 and tracked for 4 years. Methods: Following a 12-hour fast, subjects reported for measurement of body mass index (BMI), perceived…
Multi-Robot FastSLAM for Large Domains
2007-03-01
Derr, D. Fox, A.B. Cremers , Integrating global position estimation and position tracking for mobile robots: The dynamic markov localization approach...Intelligence (AAAI), 2000. 53. Andrew J. Davison and David W. Murray. Simultaneous Localization and Map- Building Using Active Vision. IEEE...Wyeth, Michael Milford and David Prasser. A Modified Particle Filter for Simultaneous Robot Localization and Landmark Tracking in an Indoor
A new fast scanning system for the measurement of large angle tracks in nuclear emulsions
NASA Astrophysics Data System (ADS)
Alexandrov, A.; Buonaura, A.; Consiglio, L.; D'Ambrosio, N.; De Lellis, G.; Di Crescenzo, A.; Di Marco, N.; Galati, G.; Lauria, A.; Montesi, M. C.; Pupilli, F.; Shchedrina, T.; Tioukov, V.; Vladymyrov, M.
2015-11-01
Nuclear emulsions have been widely used in particle physics to identify new particles through the observation of their decays thanks to their unique spatial resolution. Nevertheless, before the advent of automatic scanning systems, the emulsion analysis was very demanding in terms of well trained manpower. Due to this reason, they were gradually replaced by electronic detectors, until the '90s, when automatic microscopes started to be developed in Japan and in Europe. Automatic scanning was essential to conceive large scale emulsion-based neutrino experiments like CHORUS, DONUT and OPERA. Standard scanning systems have been initially designed to recognize tracks within a limited angular acceptance (θ lesssim 30°) where θ is the track angle with respect to a line perpendicular to the emulsion plane. In this paper we describe the implementation of a novel fast automatic scanning system aimed at extending the track recognition to the full angular range and improving the present scanning speed. Indeed, nuclear emulsions do not have any intrinsic limit to detect particle direction. Such improvement opens new perspectives to use nuclear emulsions in several fields in addition to large scale neutrino experiments, like muon radiography, medical applications and dark matter directional detection.
Pallavicini, Carla; Levi, Valeria; Wetzler, Diana E.; Angiolini, Juan F.; Benseñor, Lorena; Despósito, Marcelo A.; Bruno, Luciana
2014-01-01
The cytoskeleton is involved in numerous cellular processes such as migration, division, and contraction and provides the tracks for transport driven by molecular motors. Therefore, it is very important to quantify the mechanical behavior of the cytoskeletal filaments to get a better insight into cell mechanics and organization. It has been demonstrated that relevant mechanical properties of microtubules can be extracted from the analysis of their motion and shape fluctuations. However, tracking individual filaments in living cells is extremely complex due, for example, to the high and heterogeneous background. We introduce a believed new tracking algorithm that allows recovering the coordinates of fluorescent microtubules with ∼9 nm precision in in vitro conditions. To illustrate potential applications of this algorithm, we studied the curvature distributions of fluorescent microtubules in living cells. By performing a Fourier analysis of the microtubule shapes, we found that the curvatures followed a thermal-like distribution as previously reported with an effective persistence length of ∼20 μm, a value significantly smaller than that measured in vitro. We also verified that the microtubule-associated protein XTP or the depolymerization of the actin network do not affect this value; however, the disruption of intermediate filaments decreased the persistence length. Also, we recovered trajectories of microtubule segments in actin or intermediate filament-depleted cells, and observed a significant increase of their motion with respect to untreated cells showing that these filaments contribute to the overall organization of the microtubule network. Moreover, the analysis of trajectories of microtubule segments in untreated cells showed that these filaments presented a slower but more directional motion in the cortex with respect to the perinuclear region, and suggests that the tracking routine would allow mapping the microtubule dynamical organization in cells. PMID:24940780
NASA Astrophysics Data System (ADS)
McKenna, P.; MacLellan, D. A.; Butler, N. M. H.; Dance, R. J.; Gray, R. J.; Robinson, A. P. L.; Neely, D.; Desjarlais, M. P.
2015-06-01
The role of low-temperature electrical resistivity in defining the transport properties of mega-Ampere currents of fast (MeV) electrons in solids is investigated using 3D hybrid particle-in-cell (PIC) simulations. By considering resistivity profiles intermediate to the ordered (lattice) and disordered forms of two example materials, lithium and silicon, it is shown that both the magnitude of the resistivity and the shape of the resistivity-temperature profile at low temperatures strongly affect the self-generated resistive magnetic fields and the onset of resistive instabilities, and thus the overall fast electron beam transport pattern. The scaling of these effects to the giga-Ampere electron currents required for the fast ignition scheme for inertial fusion is also explored.
Sutcliffe, G. D.; Milanese, L. M.; Orozco, D.; ...
2016-08-05
CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint ofmore » the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.« less
NASA Astrophysics Data System (ADS)
Yang, Xinxin; Ge, Shuzhi Sam; He, Wei
2018-04-01
In this paper, both the closed-form dynamics and adaptive robust tracking control of a space robot with two-link flexible manipulators under unknown disturbances are developed. The dynamic model of the system is described with assumed modes approach and Lagrangian method. The flexible manipulators are represented as Euler-Bernoulli beams. Based on singular perturbation technique, the displacements/joint angles and flexible modes are modelled as slow and fast variables, respectively. A sliding mode control is designed for trajectories tracking of the slow subsystem under unknown but bounded disturbances, and an adaptive sliding mode control is derived for slow subsystem under unknown slowly time-varying disturbances. An optimal linear quadratic regulator method is proposed for the fast subsystem to damp out the vibrations of the flexible manipulators. Theoretical analysis validates the stability of the proposed composite controller. Numerical simulation results demonstrate the performance of the closed-loop flexible space robot system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutcliffe, G. D., E-mail: gdsut@mit.edu; Milanese, L. M.; Orozco, D.
2016-11-15
CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint ofmore » the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.« less
Navigators for motion detection during real-time MRI-guided radiotherapy
NASA Astrophysics Data System (ADS)
Stam, Mette K.; Crijns, Sjoerd P. M.; Zonnenberg, Bernard A.; Barendrecht, Maurits M.; van Vulpen, Marco; Lagendijk, Jan J. W.; Raaymakers, Bas W.
2012-11-01
An MRI-linac system provides direct MRI feedback and with that the possibility of adapting radiation treatments to the actual tumour position. This paper addresses the use of fast 1D MRI, pencil-beam navigators, for this feedback. The accuracy of using navigators was determined on a moving phantom. The possibility of organ tracking and breath-hold monitoring based on navigator guidance was shown for the kidney. Navigators are accurate within 0.5 mm and the analysis has a minimal time lag smaller than 30 ms as shown for the phantom measurements. The correlation of 2D kidney images and navigators shows the possibility of complete organ tracking. Furthermore the breath-hold monitoring of the kidney is accurate within 1.5 mm, allowing gated radiotherapy based on navigator feedback. Navigators are a fast and precise method for monitoring and real-time tracking of anatomical landmarks. As such, they provide direct MRI feedback on anatomical changes for more precise radiation delivery.
Joint polarization tracking and channel equalization based on radius-directed linear Kalman filter
NASA Astrophysics Data System (ADS)
Zhang, Qun; Yang, Yanfu; Zhong, Kangping; Liu, Jie; Wu, Xiong; Yao, Yong
2018-01-01
We propose a joint polarization tracking and channel equalization scheme based on radius-directed linear Kalman filter (RD-LKF) by introducing the butterfly finite-impulse-response (FIR) filter in our previously proposed RD-LKF method. Along with the fast polarization tracking, it can also simultaneously compensate the inter-symbol interference (ISI) effects including residual chromatic dispersion and polarization mode dispersion. Compared with the conventional radius-directed equalizer (RDE) algorithm, it is demonstrated experimentally that three times faster convergence speed, one order of magnitude better tracking capability, and better BER performance is obtained in polarization division multiplexing 16 quadrature amplitude modulation system. Besides, the influences of the algorithm parameters on the convergence and the tracking performance are investigated by numerical simulation.
Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hansen, Rune; Ravkilde, Thomas; Worm, Esben Schjødt
2016-05-15
Purpose: Couch and MLC tracking are two promising methods for real-time motion compensation during radiation therapy. So far, couch and MLC tracking experiments have mainly been performed by different research groups, and no direct comparison of couch and MLC tracking of volumetric modulated arc therapy (VMAT) plans has been published. The Varian TrueBeam 2.0 accelerator includes a prototype tracking system with selectable couch or MLC compensation. This study provides a direct comparison of the two tracking types with an otherwise identical setup. Methods: Several experiments were performed to characterize the geometric and dosimetric performance of electromagnetic guided couch and MLCmore » tracking on a TrueBeam accelerator equipped with a Millennium MLC. The tracking system latency was determined without motion prediction as the time lag between sinusoidal target motion and the compensating motion of the couch or MLC as recorded by continuous MV portal imaging. The geometric and dosimetric tracking accuracies were measured in tracking experiments with motion phantoms that reproduced four prostate and four lung tumor trajectories. The geometric tracking error in beam’s eye view was determined as the distance between an embedded gold marker and a circular MLC aperture in continuous MV images. The dosimetric tracking error was quantified as the measured 2%/2 mm gamma failure rate of a low and a high modulation VMAT plan delivered with the eight motion trajectories using a static dose distribution as reference. Results: The MLC tracking latency was approximately 146 ms for all sinusoidal period lengths while the couch tracking latency increased from 187 to 246 ms with decreasing period length due to limitations in the couch acceleration. The mean root-mean-square geometric error was 0.80 mm (couch tracking), 0.52 mm (MLC tracking), and 2.75 mm (no tracking) parallel to the MLC leaves and 0.66 mm (couch), 1.14 mm (MLC), and 2.41 mm (no tracking) perpendicular to the leaves. The motion-induced gamma failure rate was in mean 0.1% (couch tracking), 8.1% (MLC tracking), and 30.4% (no tracking) for prostate motion and 2.9% (couch), 2.4% (MLC), and 41.2% (no tracking) for lung tumor motion. The residual tracking errors were mainly caused by inadequate adaptation to fast lung tumor motion for couch tracking and to prostate motion perpendicular to the MLC leaves for MLC tracking. Conclusions: Couch and MLC tracking markedly improved the geometric and dosimetric accuracies of VMAT delivery. However, the two tracking types have different strengths and weaknesses. While couch tracking can correct perfectly for slowly moving targets such as the prostate, MLC tracking may have considerably larger dose errors for persistent target shift perpendicular to the MLC leaves. Advantages of MLC tracking include faster dynamics with better adaptation to fast moving targets, the avoidance of moving the patient, and the potential to track target rotations and deformations.« less
OPTICAL TRANSCRIBING OSCILLOSCOPE
Kerns, Q.A.
1961-09-26
A device is designed for producing accurate graphed waveforms of very fast electronic pulses. The fast pulse is slowly tracked on a cathode ray tube and a pair of photomultiplier tubes, exposed to the pulse trace, view separate vertical portions thereof at each side of a fixed horizontal reference. Each phototube produces an output signal indicative of vertical movement of the exposed trace, which simultaneous signals are compared in a difference amplifier. The amplifier produces a difference signal which, when applied to the cathode ray tube, maintains the trace on the reference. A graphic recorder receives the amplified difference signal at an x-axis input, while a y-axis input is synchronized with the tracking time of the cathode ray tube and therefore graphs the enlarged waveshape.
Event Management of RFID Data Streams: Fast Moving Consumer Goods Supply Chains
NASA Astrophysics Data System (ADS)
Mo, John P. T.; Li, Xue
Radio Frequency Identification (RFID) is a wireless communication technology that uses radio-frequency waves to transfer information between tagged objects and readers without line of sight. This creates tremendous opportunities for linking real world objects into a world of "Internet of things". Application of RFID to Fast Moving Consumer Goods sector will introduce billions of RFID tags in the world. Almost everything is tagged for tracking and identification purposes. This phenomenon will impose a new challenge not only to the network capacity but also to the scalability of processing of RFID events and data. This chapter uses two national demonstrator projects in Australia as case studies to introduce an event managementframework to process high volume RFID data streams in real time and automatically transform physical RFID observations into business-level events. The model handles various temporal event patterns, both simple and complex, with temporal constraints. The model can be implemented in a data management architecture that allows global RFID item tracking and enables fast, large-scale RFID deployment.
Bothe, Jameson R.; Stein, Zachary W.; Al-Hashimi, Hashim M.
2014-01-01
Spin relaxation in the rotating frame (R1ρ) is a powerful NMR technique for characterizing fast microsecond timescale exchange processes directed toward short-lived excited states in biomolecules. At the limit of fast exchange, only kex = k1 + k−1 and Φıx = pGpE(Δω)2 can be determined from R1ρ data limiting the ability to characterize the structure and energetics of the excited state conformation. Here, we use simulations to examine the uncertainty with which exchange parameters can be determined for two state systems in intermediate-to-fast exchange using off-resonance R1ρ relaxation dispersion. R1ρ data computed by solving the Bloch-McConnell equations reveals small but significant asymmetry with respect to offset (R1ρ(ΔΩ) ≠ R1ρ(−ΔΩ)), which is a hallmark of slow-to-intermediate exchange, even under conditions of fast exchange for free precession chemical exchange line broadening (kex/Δω > 10). A grid search analysis combined with bootstrap and Monte-Carlo based statistical approaches for estimating uncertainty in exchange parameters reveals that both the sign and magnitude of Δω can be determined at a useful level of uncertainty for systems in fast exchange (kex/Δω < 10) but that this depends on the uncertainty in the R1ρ data and requires a thorough examination of the multidimensional variation of χ2 as a function of exchange parameters. Results from simulations are complemented by analysis of experimental R1ρ data measured in three nucleic acid systems with exchange processes occurring on the slow (kex/Δω = 0.2; pE = ~ 0.7%), fast (kex/Δω = ~10–16; pE = ~13%) and very fast (kex = 39,000 s−1) chemical shift timescales. PMID:24819426
Incident angle dependence of proton response of CR-39 (TS-16) track detector
NASA Technical Reports Server (NTRS)
Oda, K.; Csige, I.; Yamauchi, T.; Miyake, H.; Benton, E. V.
1993-01-01
The proton response of the TS-16 type of CR-39 plastic nuclear track detector has been studied with accelerated and fast neutron induced protons in vacuum and in air. The diameters of etched tracks were measured as a function of etching time and the etch rate ratio and the etch induction layer were determined from the growth curve of the diameter using a variable etch rate ratio model. In the case of the accelerated protons in vacuum an anomalous incident angle dependence of the response is observed.
Fast Track Teacher Education: A Review of the Research Literature on "Teach For All" Schemes
ERIC Educational Resources Information Center
McConney, Andrew; Price, Anne; Woods-McConney, Amanda
2012-01-01
This review of the research literature was commissioned by the New Zealand Post-Primary Teachers Association (PPTA) Te Wehengarua as a means of informing the decision-making of the Association and its members about the Teach For All (TFA) scheme seeking to prepare teachers for New Zealand's schools. The systematic review is about fast track…
ERIC Educational Resources Information Center
Hertrich, Ingo; Dietrich, Susanne; Ackermann, Hermann
2013-01-01
Blind people can learn to understand speech at ultra-high syllable rates (ca. 20 syllables/s), a capability associated with hemodynamic activation of the central-visual system. To further elucidate the neural mechanisms underlying this skill, magnetoencephalographic (MEG) measurements during listening to sentence utterances were cross-correlated…
Getting a College Degree Fast: Testing Out & Other Accredited Short Cuts.
ERIC Educational Resources Information Center
Aber, Joanne
This book, directed especially to individuals over age 30, takes a how-to approach to earning a college degree in the least amount of time for the least amount of money. The book explains how to use fast-track methods such as "testing out," which takes advantage of prior learning, and accredited shortcuts to earn an accelerated degree. The first…
Tracking Site-specific C-C Coupling of Formaldehyde Molecules on Rutile TiO2(110)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Ke; Xia, Yaobiao; Tang, Miru
2015-06-25
Direct imaging of site-specific reactions of individual mole-cules as a function of temperature is a long-sought goal in molecular science. Here, we report the direct visualization of molecular coupling of formaldehyde on reduced rutile TiO2(110) surfaces as we track the same set of molecules when the temperature is increased from 75 to 170 K using scanning tunneling microscope (STM). Our recent study showed that formaldehyde preferably adsorbs on bridging-bonded oxygen (Ob) vacancy (VO) defect site. Herein, images from the same area as the temperature is increased show that VO-bound formaldehyde couples with Ti-bound formaldehyde forming a diolate intermediate. Exposure ofmore » formaldehyde at room temperature leads to diolate as the majority species on the surface and no VO-bound formaldehyde is observed. The diolate species are the key reaction intermediates in the formation of ethylene reported in previous ensemble-averaged studies.« less
Integrated mobile robot control
NASA Technical Reports Server (NTRS)
Amidi, Omead; Thorpe, Charles
1991-01-01
This paper describes the structure, implementation, and operation of a real-time mobile robot controller which integrates capabilities such as: position estimation, path specification and tracking, human interfaces, fast communication, and multiple client support. The benefits of such high-level capabilities in a low-level controller was shown by its implementation for the Navlab autonomous vehicle. In addition, performance results from positioning and tracking systems are reported and analyzed.
Two-dimensional models of early-type fast rotating stars: the ESTER project
NASA Astrophysics Data System (ADS)
Rieutord, Michel
In this talk I present the latest results of the ESTER project that has taken up the challenge of building two dimensional (axisymmetric) models of stars rotating at any rotation rate. In particular, I focus on main sequence massive and intermediate mass stars. I show what should be expected in such stars as far as the differential rotation and the associated meridional circulation are concerned, notably the emergence of a Stewartson layer along the tangent cylinder of the core. I also indicate what may be inferred about the evolution of an intermediate-mass star at constant angular momentum and how Be stars may form. I finally give some comparisons between models and observations of the gravity darkening on some nearby fast rotators as it has been derived from interferometric observations. In passing, I also discuss how 2D models can help to recover the fundamental parameters of a star.
LARGE SUPER-FAST ROTATOR HUNTING USING THE INTERMEDIATE PALOMAR TRANSIENT FACTORY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Chan-Kao; Lin, Hsing-Wen; Ip, Wing-Huen
In order to look for large super-fast rotators, in late 2014 and early 2015, five dedicated surveys covering ∼188 deg{sup 2} in the ecliptic plane have been carried out in the R -band, with ∼10 minute cadence using the intermediate Palomar Transient Factory. Among 1029 reliable rotation periods obtained from the surveys, we discovered 1 new large super-fast rotator, (40511) 1999 RE88, and 18 other candidates. (40511) 1999 RE88 is an S-type inner main-belt asteroid with a diameter of D = 1.9 ± 0.3 km, a rotation period of P = 1.96 ± 0.01 hr, and a light curve amplitude of Δ m ∼ 1.0 mag. To maintainmore » such fast rotation, an internal cohesive strength of ∼780 Pa is required. Combining all known large super-fast rotators, their cohesive strengths all fall in the range of 100–1000 Pa of lunar regolith. However, the number of large super-fast rotators seems to be far less than the whole asteroid population. This might indicate a peculiar asteroid group for them. Although the detection efficiency for a long rotation period is greatly reduced due to our two-day observation time span, the spin-rate distributions of this work show consistent results with Chang et al. (2015), after considering the possible observational bias in our surveys. It shows a number decrease with an increase of spin rate for asteroids with a diameter of 3 ⩽ D ⩽ 15 km, and a number drop at a spin rate of f = 5 rev day{sup −1} for asteroids with D ⩽ 3 km.« less
Votava, Ondrej; Mašát, Milan; Parker, Alexander E; Jain, Chaithania; Fittschen, Christa
2012-04-01
We present in this work a new tracking servoloop electronics for continuous wave cavity-ringdown absorption spectroscopy (cw-CRDS) and its application to time resolved cw-CRDS measurements by coupling the system with a pulsed laser photolysis set-up. The tracking unit significantly increases the repetition rate of the CRDS events and thus improves effective time resolution (and/or the signal-to-noise ratio) in kinetics studies with cw-CRDS in given data acquisition time. The tracking servoloop uses novel strategy to track the cavity resonances that result in a fast relocking (few ms) after the loss of tracking due to an external disturbance. The microcontroller based design is highly flexible and thus advanced tracking strategies are easy to implement by the firmware modification without the need to modify the hardware. We believe that the performance of many existing cw-CRDS experiments, not only time-resolved, can be improved with such tracking unit without any additional modification to the experiment. © 2012 American Institute of Physics
Decontaminate feature for tracking: adaptive tracking via evolutionary feature subset
NASA Astrophysics Data System (ADS)
Liu, Qiaoyuan; Wang, Yuru; Yin, Minghao; Ren, Jinchang; Li, Ruizhi
2017-11-01
Although various visual tracking algorithms have been proposed in the last 2-3 decades, it remains a challenging problem for effective tracking with fast motion, deformation, occlusion, etc. Under complex tracking conditions, most tracking models are not discriminative and adaptive enough. When the combined feature vectors are inputted to the visual models, this may lead to redundancy causing low efficiency and ambiguity causing poor performance. An effective tracking algorithm is proposed to decontaminate features for each video sequence adaptively, where the visual modeling is treated as an optimization problem from the perspective of evolution. Every feature vector is compared to a biological individual and then decontaminated via classical evolutionary algorithms. With the optimized subsets of features, the "curse of dimensionality" has been avoided while the accuracy of the visual model has been improved. The proposed algorithm has been tested on several publicly available datasets with various tracking challenges and benchmarked with a number of state-of-the-art approaches. The comprehensive experiments have demonstrated the efficacy of the proposed methodology.
Airborne optical tracking control system design study
NASA Astrophysics Data System (ADS)
1992-09-01
The Kestrel LOS Tracking Program involves the development of a computer and algorithms for use in passive tracking of airborne targets from a high altitude balloon platform. The computer receivers track error signals from a video tracker connected to one of the imaging sensors. In addition, an on-board IRU (gyro), accelerometers, a magnetometer, and a two-axis inclinometer provide inputs which are used for initial acquisitions and course and fine tracking. Signals received by the control processor from the video tracker, IRU, accelerometers, magnetometer, and inclinometer are utilized by the control processor to generate drive signals for the payload azimuth drive, the Gimballed Mirror System (GMS), and the Fast Steering Mirror (FSM). The hardware which will be procured under the LOS tracking activity is the Controls Processor (CP), the IRU, and the FSM. The performance specifications for the GMS and the payload canister azimuth driver are established by the LOS tracking design team in an effort to achieve a tracking jitter of less than 3 micro-rad, 1 sigma for one axis.
Two-degrees-of-freedom piezo-driven fast steering mirror with cross-axis decoupling capability
NASA Astrophysics Data System (ADS)
Shao, Shubao; Tian, Zheng; Song, Siyang; Xu, Minglong
2018-05-01
Because mechanical cross coupling between its axes would lead to degradation of the scanning precision of a piezo-driven fast steering mirror (PFSM), a two-degrees-of-freedom (2-DoF) PFSM with a cross-axis decoupling capability, in which 2-DoF flexure hinges are used, is proposed in this work. The overall structure of the proposed PFSM is first introduced and then both static and dynamic models are established analytically; in addition, the decoupling mechanism is described in detail and the low dynamic cross coupling ratios that occur between the two DoFs are shown. Because of the decoupling property of the PFSM, the 2-DoF motion is treated as a combination of two independent one-degree-of-freedom (1-DoF) motions and two independent proportional-integral-derivative controllers are thus used separately in the control of the two DoFs. Based on this control strategy, experiments involving both 1-DoF trajectory tracking and 2-DoF trajectory tracking are implemented. The test results show that the proposed PFSM can achieve the tilt range of ±7 mrad for both axes with the low coupling ratios that are less than 2% (-34 dB), and the bandwidths of both axes are higher than 810 Hz; in addition, the maximal tracking full scale range errors for 1-DoF trajectory tracking and 2-DoF trajectory tracking are less than 0.2% and 1%, respectively, where the larger error of 2-DoF trajectory tracking is mainly caused by the remaining cross coupling between axes.
Multiple-target tracking implementation in the ebCMOS camera system: the LUSIPHER prototype
NASA Astrophysics Data System (ADS)
Doan, Quang Tuyen; Barbier, Remi; Dominjon, Agnes; Cajgfinger, Thomas; Guerin, Cyrille
2012-06-01
The domain of the low light imaging systems progresses very fast, thanks to detection and electronic multiplication technology evolution, such as the emCCD (electron multiplying CCD) or the ebCMOS (electron bombarded CMOS). We present an ebCMOS camera system that is able to track every 2 ms more than 2000 targets with a mean number of photons per target lower than two. The point light sources (targets) are spots generated by a microlens array (Shack-Hartmann) used in adaptive optics. The Multiple-Target-Tracking designed and implemented on a rugged workstation is described. The results and the performances of the system on the identification and tracking are presented and discussed.
Multi-Stage Target Tracking with Drift Correction and Position Prediction
NASA Astrophysics Data System (ADS)
Chen, Xin; Ren, Keyan; Hou, Yibin
2018-04-01
Most existing tracking methods are hard to combine accuracy and performance, and do not consider the shift between clarity and blur that often occurs. In this paper, we propound a multi-stage tracking framework with two particular modules: position prediction and corrective measure. We conduct tracking based on correlation filter with a corrective measure module to increase both performance and accuracy. Specifically, a convolutional network is used for solving the blur problem in realistic scene, training methodology that training dataset with blur images generated by the three blur algorithms. Then, we propose a position prediction module to reduce the computation cost and make tracker more capable of fast motion. Experimental result shows that our tracking method is more robust compared to others and more accurate on the benchmark sequences.
Determination of time zero from a charged particle detector
Green, Jesse Andrew [Los Alamos, NM
2011-03-15
A method, system and computer program is used to determine a linear track having a good fit to a most likely or expected path of charged particle passing through a charged particle detector having a plurality of drift cells. Hit signals from the charged particle detector are associated with a particular charged particle track. An initial estimate of time zero is made from these hit signals and linear tracks are then fit to drift radii for each particular time-zero estimate. The linear track having the best fit is then searched and selected and errors in fit and tracking parameters computed. The use of large and expensive fast detectors needed to time zero in the charged particle detectors can be avoided by adopting this method and system.
Wodlin, Ninnie Borendal; Nilsson, Lena; Arestedt, Kristofer; Kjølhede, Preben
2011-04-01
To determine whether postoperative symptoms differ between women who undergo abdominal benign hysterectomy in a fast-track model under general anesthesia or spinal anesthesia with intrathecal morphine. Secondary analysis from a randomized, open, multicenter study. Five hospitals in south-east Sweden. One-hundred and eighty women scheduled for benign hysterectomy were randomized; 162 completed the study; 82 were allocated to spinal and 80 to general anesthesia. The Swedish Postoperative Symptoms Questionnaire, completed daily for 1 week and thereafter once a week until 5 weeks postoperatively. Occurrence, intensity and duration of postoperative symptoms. Women who had hysterectomy under spinal anesthesia with intrathecal morphine experienced significantly less discomfort postoperatively compared with those who had the operation under general anesthesia. Spinal anesthesia reduced the need for opioids postoperatively. The most common symptoms were pain, nausea and vomiting, itching, drowsiness and fatigue. Abdominal pain, drowsiness and fatigue occurred significantly less often and with lower intensity among the spinal anesthesia group. Although postoperative nausea and vomiting was reported equally in the two groups, vomiting episodes were reported significantly more often during the first day after surgery in the spinal anesthesia group. Spinal anesthesia was associated with a higher prevalence of postoperative itching. Spinal anesthesia with intrathecal morphine carries advantages regarding postoperative symptoms and recovery following fast-track abdominal hysterectomy. © 2011 The Authors Acta Obstetricia et Gynecologica Scandinavica© 2011 Nordic Federation of Societies of Obstetrics and Gynecology.
How to optimize the economic viability of thyroid surgery in a French public hospital?
D'Hubert, E; Proske, J-M
2010-08-01
Physicians in France have been asked to change their day-to-day medical practice to reduce overall costs. We examine ways to achieve this goal in thyroid surgery. We defined and implemented a clinical pathway to optimize the economic viability of thyroid surgery by increasing revenues and lowering expenses. An increase in revenue was achieved by decreasing patient length of stay (LOS) through the use of a fast-track rehabilitation protocol. Expenses were decreased by performing all pre-operative work-up in the out-patient setting and by decreasing costs in the operating room. For 292 consecutive patients who underwent thyroidectomy, the average LOS has been decreased over time to a mean of 2.03 days in 2008; 96% of patients were discharged on the first postoperative day. These results were primarily achieved by using a fast-track rehabilitation clinical pathway, and no increase in postoperative morbidity was noted. Operating time was decreased by 20% through the use of a second surgical assistant and hemostatic scissors but this improvement did not translate into better daily utilization of the operating room. The economic profitability of thyroid surgery is improved when mean LOS is reduced to 2 days through a fast-track protocol. Decreasing the duration of hospitalization was more effective than decreasing operative duration in controlling overall costs. Copyright © 2010 Elsevier Masson SAS. All rights reserved.
Patil, P; Williams, M; Maw, W W; Achilleos, K; Elsideeg, S; Dejaco, C; Borg, F; Gupta, S; Dasgupta, B
2015-01-01
To investigate the effectiveness of a fast track pathway (FTP) on sight loss in patients with suspected giant cell arteritis (GCA). A longitudinal observational cohort study was conducted in the secondary care rheumatology department. One hundred and thirty-five newly referred suspected GCA patients seen via the FTP (Jan. 2012-Dec. 2013) were compared to 81 patients seen through the conventional referral and review system (Jan. 2009-Dec. 2011). The FTP resulted in significant reduction in irreversible sight loss from 37.0% (as seen in the historical cohort 2009-2011) to 9.0 % (2012-2013, OR 0.17, p=0.001). Adjustment for clinical and demographic parameters including known risk factors for GCA associated blindness did not significantly change the primary result (OR 0.08, p=0.001). FTP resulted in a reduction of time from symptom onset to diagnosis, particularly by reduction of time from general practitioner's (GP) referral to the rheumatology review (79% of FTP patients were seen within one working day compared to 64.6 % in the conventional pathway, p=0.023). The FTP has seen a reduction in number of GP appointments. There was a significant reduction of permanent sight loss with a fast track GCA pathway. The effect may be due to multiple factors including better GP education and reduction in delayed diagnosis. These results need verification at other sites.
Evidence of extensive plasma glucose recycling following a glucose load in seabass.
Rito, João; Viegas, Ivan; Pardal, Miguel A; Jones, John G
2017-09-01
Seabass and other carnivorous fish are highly dependent on gluconeogenesis from dietary amino acids to maintain glycemia. Glucose recycling (glucose→C3-intermediate→glucose) may potentiate the effects of glucose administration in sparing amino acid gluconeogenesis. To date, very few measurements of glucose recycling have been reported in fish. Thus, to determine the extent of glucose recycling following a glycemic challenge, juvenile seabass were given an intraperitoneal glucose load (2gkg -1 ) enriched with [U- 13 C]glucose. 13 C NMR analysis of plasma glucose 13 C-isotopomers was used to determine the fractional contributions of glucose derived directly from the load versus that from glucose recycling at 48h after the load. Both fed and 21-day fasted fish (20 per condition) were studied. In fasted fish, 18±4% of plasma glucose was directly derived from the load while 13±2% was derived from glucose recycling. In fed fish, the load accounted for 6±1% of plasma glucose levels while glucose recycling contributed 16±4%. 13 C NMR analysis of plasma lactate revealed 13 C-isotopomers corresponding to the expected C3-intermediates of peripheral [U- 13 C]glucose catabolism indicating that circulating lactate was a key intermediate in glucose carbon recycling under these conditions. In conclusion, glucose recycling was shown to contribute a significant portion of plasma glucose levels in both fed and fasted seabass 48h after an intraperitoneal glucose challenge and circulating lactate was shown to be an intermediate of this pathway. Copyright © 2017. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Zhi-Jun; Zhan, Fei; Xiao, Hongyan
X-ray transient absorption spectroscopy (XTA) and optical transient spectroscopy (OTA) were used to probe the Co(I) intermediate generated in situ from an aqueous photocatalytic hydrogen evolution system, with [RuII(bpy)3]Cl2·6H2O as the photosensitizer, ascorbic acid/ascorbate as the electron donor, and the Co-polypyridyl complex ([CoII(DPABpy) Cl]Cl) as the pre-catalyst. Upon exposure to light, the XTA measured at Co K-edge visualizes the grow and decay of the Co(I) intermediate, and reveals its Co-N bond contraction of 0.09 ± 0.03 Å. Density functional theory (DFT) calculations support the bond contraction and illustrate that the metal-to-ligand π back-bonding greatly stabilizes the penta-coordinated Co(I) intermediate, whichmore » provides easy photon access. To the best of our knowledge, this is the first example of capturing the penta-coordinated Co(I) intermediate in operando with bond contraction by XTA, thereby providing new insights for fundamental understanding of structure– function relationship of cobalt-based molecular catalysts.« less
Metabolic Evidence of Diminished Lipid Oxidation in Women With Polycystic Ovary Syndrome
Whigham, Leah D.; Butz, Daniel E.; Dashti, Hesam; Tonelli, Marco; Johnson, LuAnn K.; Cook, Mark E.; Porter, Warren P.; Eghbalnia, Hamid R.; Markley, John L.; Lindheim, Steven R.; Schoeller, Dale A.; Abbott, David H.; Assadi-Porter, Fariba M.
2014-01-01
Polycystic ovary syndrome (PCOS), a common female endocrinopathy, is a complex metabolic syndrome of enhanced weight gain. The goal of this pilot study was to evaluate metabolic differences between normal (n=10) and PCOS (n=10) women via breath carbon isotope ratio, urinary nitrogen and nuclear magnetic resonance (NMR)-determined serum metabolites. Breath carbon stable isotopes measured by cavity ring down spectroscopy (CRDS) indicated diminished (p<0.030) lipid use as a metabolic substrate during overnight fasting in PCOS compared to normal women. Accompanying urinary analyses showed a trending correlation (p<0.057) between overnight total nitrogen and circulating testosterone in PCOS women, alone. Serum analyzed by NMR spectroscopy following overnight, fast and at 2 h following an oral glucose tolerance test showed that a transient elevation in blood glucose levels decreased circulating levels of lipid, glucose and amino acid metabolic intermediates (acetone, 2-oxocaporate, 2-aminobutyrate, pyruvate, formate, and sarcosine) in PCOS women, whereas the 2 h glucose challenge led to increases in the same intermediates in normal women. These pilot data suggest that PCOS-related inflexibility in fasting-related switching between lipid and carbohydrate/protein utilization for carbon metabolism may contribute to enhanced weight gain. PMID:24765590
Zhu, Ying; You, Xinru; Huang, Keqing; Raza, Faisal; Lu, Xin; Chen, Yuejian; Dhinakar, Arvind; Zhang, Yuan; Kang, Yang; Wu, Jun; Ge, Liang
2018-07-27
Fast dissolving oral film is a stamp-style, drug-loaded polymer film with rapid disintegration and dissolution. This new kind of drug delivery system requires effective taste masking technology. Suspension intermediate and liposome intermediate were prepared, respectively, for the formulation of two kinds of fast dissolving oral films with the aim of studying the effect of taste masking technology on the bioavailability of oral films. Loratadine was selected as the model drug. The surface pH of the films was close to neutral, avoiding oral mucosal irritation or side effects. The thickness of a 2 cm × 2 cm suspension oral film containing 10 mg of loratadine was 100 μm. Electron microscope analysis showed that liposomes were spherical before and after re-dissolution, and drugs with obvious bitterness could be masked by the encapsulation of liposomes. Dissolution of the two films was superior to that of the commercial tablets. Rat pharmacokinetic experiments showed that the oral bioavailability of the suspension film was significantly higher than that of the commercial tablets, and the relative bioavailability of the suspension film was 175%. Liposomal film produced a certain amount of improvement in bioavailability, but lower than that of the suspension film.
NASA Astrophysics Data System (ADS)
Zhu, Ying; You, Xinru; Huang, Keqing; Raza, Faisal; Lu, Xin; Chen, Yuejian; Dhinakar, Arvind; Zhang, Yuan; Kang, Yang; Wu, Jun; Ge, Liang
2018-07-01
Fast dissolving oral film is a stamp-style, drug-loaded polymer film with rapid disintegration and dissolution. This new kind of drug delivery system requires effective taste masking technology. Suspension intermediate and liposome intermediate were prepared, respectively, for the formulation of two kinds of fast dissolving oral films with the aim of studying the effect of taste masking technology on the bioavailability of oral films. Loratadine was selected as the model drug. The surface pH of the films was close to neutral, avoiding oral mucosal irritation or side effects. The thickness of a 2 cm × 2 cm suspension oral film containing 10 mg of loratadine was 100 μm. Electron microscope analysis showed that liposomes were spherical before and after re-dissolution, and drugs with obvious bitterness could be masked by the encapsulation of liposomes. Dissolution of the two films was superior to that of the commercial tablets. Rat pharmacokinetic experiments showed that the oral bioavailability of the suspension film was significantly higher than that of the commercial tablets, and the relative bioavailability of the suspension film was 175%. Liposomal film produced a certain amount of improvement in bioavailability, but lower than that of the suspension film.
Two-dimensional models of fast rotating early-type stars
NASA Astrophysics Data System (ADS)
Rieutord, Michel
2015-08-01
Rotation has now become an unavoidable parameter of stellar models, but for most massive or intermediate-mass stars rotation is fast, at least of a significant fraction of the critical angular velocity. Current spherically symmetric models try to cope with this feature of the stars using various approximations, like for instance the so-called shellular rotation usually accompanied with a diffusion that is meant to represent the mixing induced by rotationally generated flows. Such approximations may be justified in the limit of slow rotation where anisotropies and associated flows are weak. However, when rotation is fast, say larger than 50% of the critical velocities the use of a spherically symmetric 1D-model is doubtful. This is not only because of the centrifugal flattening of the star, but also because of the flows that are induced by the baroclinic torque that naturally appears in the radiative envelope of an early-type (rotating) star. These flows face the cylindrical symmetry of the Coriolis force and the spheroidal symmetry of the effective gravity.In this talk I shall present the latest results of the ESTER project that has taken up the challenge of making two-dimensional (axisymmetric) models of stars rotating at any rotation rate. In particular, I will focus on main sequence massive and intermediate-mass stars. I'll show what should be expected in such stars as far as the differential rotation and the associated meridional circulation are concerned, notably the emergence of a Stewartson layer along the tangential cylinder of the core. I'll also indicate what may be inferred about the evolution of an intermediate-mass star at constant angular momentum and how Be stars may form. I shall finally give some comparisons between models and observations of the gravity darkening on some nearby fast rotators as it has been derived from interferometric observations. In passing, I'll also discuss how 2D models can help to recover the fundamental parameters of a star.
Fast-synchronizing high-fidelity spread-spectrum receiver
Moore, Michael Roy; Smith, Stephen Fulton; Emery, Michael Steven
2004-06-01
A fast-synchronizing receiver having a circuit including an equalizer configured for manipulating an analog signal; a detector in communication with the equalizer; a filter in communication with the detector; an oscillator in communication with the filter; a gate for receiving the manipulated signal; a circuit portion for synchronizing and tracking the manipulated signal; a summing circuit in communication with the circuit portion; and an output gate.
Assessment of the high temperature fission chamber technology for the French fast reactor program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jammes, C.; Filliatre, P.; Geslot, B.
2011-07-01
High temperature fission chambers are key instruments for the control and protection of the sodium-cooled fast reactor. First, the developments of those neutron detectors, which are carried out either in France or abroad are reviewed. Second, the French realizations are assessed with the use of the technology readiness levels in order to identify tracks of improvement. (authors)
Fast and Efficient Feature Engineering for Multi-Cohort Analysis of EHR Data.
Ozery-Flato, Michal; Yanover, Chen; Gottlieb, Assaf; Weissbrod, Omer; Parush Shear-Yashuv, Naama; Goldschmidt, Yaara
2017-01-01
We present a framework for feature engineering, tailored for longitudinal structured data, such as electronic health records (EHRs). To fast-track feature engineering and extraction, the framework combines general-use plug-in extractors, a multi-cohort management mechanism, and modular memoization. Using this framework, we rapidly extracted thousands of features from diverse and large healthcare data sources in multiple projects.
NASA Technical Reports Server (NTRS)
Frigerio, N. A.; Nellans, H. N.; Shaw, M. J.
1969-01-01
Reports relate applications of neutrons to the problem of cancer therapy. The biochemical and biophysical aspects of fast-neutron therapy, neutron-capture and neutron-conversion therapy with intermediate-range neutrons are presented. Also included is a computer program for neutron-gamma radiobiology.
Registration of retinal sequences from new video-ophthalmoscopic camera.
Kolar, Radim; Tornow, Ralf P; Odstrcilik, Jan; Liberdova, Ivana
2016-05-20
Analysis of fast temporal changes on retinas has become an important part of diagnostic video-ophthalmology. It enables investigation of the hemodynamic processes in retinal tissue, e.g. blood-vessel diameter changes as a result of blood-pressure variation, spontaneous venous pulsation influenced by intracranial-intraocular pressure difference, blood-volume changes as a result of changes in light reflection from retinal tissue, and blood flow using laser speckle contrast imaging. For such applications, image registration of the recorded sequence must be performed. Here we use a new non-mydriatic video-ophthalmoscope for simple and fast acquisition of low SNR retinal sequences. We introduce a novel, two-step approach for fast image registration. The phase correlation in the first stage removes large eye movements. Lucas-Kanade tracking in the second stage removes small eye movements. We propose robust adaptive selection of the tracking points, which is the most important part of tracking-based approaches. We also describe a method for quantitative evaluation of the registration results, based on vascular tree intensity profiles. The achieved registration error evaluated on 23 sequences (5840 frames) is 0.78 ± 0.67 pixels inside the optic disc and 1.39 ± 0.63 pixels outside the optic disc. We compared the results with the commonly used approaches based on Lucas-Kanade tracking and scale-invariant feature transform, which achieved worse results. The proposed method can efficiently correct particular frames of retinal sequences for shift and rotation. The registration results for each frame (shift in X and Y direction and eye rotation) can also be used for eye-movement evaluation during single-spot fixation tasks.
Radiation-hardened fast acquisition/weak signal tracking system and method
NASA Technical Reports Server (NTRS)
Winternitz, Luke (Inventor); Boegner, Gregory J. (Inventor); Sirotzky, Steve (Inventor)
2009-01-01
A global positioning system (GPS) receiver and method of acquiring and tracking GPS signals comprises an antenna adapted to receive GPS signals; an analog radio frequency device operatively connected to the antenna and adapted to convert the GPS signals from an analog format to a digital format; a plurality of GPS signal tracking correlators operatively connected to the analog RF device; a GPS signal acquisition component operatively connected to the analog RF device and the plurality of GPS signal tracking correlators, wherein the GPS signal acquisition component is adapted to calculate a maximum vector on a databit correlation grid; and a microprocessor operatively connected to the plurality of GPS signal tracking correlators and the GPS signal acquisition component, wherein the microprocessor is adapted to compare the maximum vector with a predetermined correlation threshold to allow the GPS signal to be fully acquired and tracked.
Theoretical prediction of the impact of Auger recombination on charge collection from an ion track
NASA Technical Reports Server (NTRS)
Edmonds, Larry D.
1991-01-01
A recombination mechanism that significantly reduces charge collection from very dense ion tracks in silicon devices was postulated by Zoutendyk et al. The theoretical analysis presented here concludes that Auger recombination is such a mechanism and is of marginal importance for higher density tracks produced by 270-MeV krypton, but of major importance for higher density tracks. The analysis shows that recombination loss is profoundly affected by track diffusion. As the track diffuses, the density and recombination rate decrease so fast that the linear density (number of electron-hole pairs per unit length) approaches a non-zero limiting value as t yields infinity. Furthermore, the linear density is very nearly equal to this limiting value in a few picoseconds or less. When Auger recombination accompanies charge transport processes that have much longer time scales, it can be simulated by assigning a reduced linear energy transfer to the ion.
Jiang, Jingfeng; Hall, Timothy J
2011-04-01
A hybrid approach that inherits both the robustness of the regularized motion tracking approach and the efficiency of the predictive search approach is reported. The basic idea is to use regularized speckle tracking to obtain high-quality seeds in an explorative search that can be used in the subsequent intelligent predictive search. The performance of the hybrid speckle-tracking algorithm was compared with three published speckle-tracking methods using in vivo breast lesion data. We found that the hybrid algorithm provided higher displacement quality metric values, lower root mean squared errors compared with a locally smoothed displacement field, and higher improvement ratios compared with the classic block-matching algorithm. On the basis of these comparisons, we concluded that the hybrid method can further enhance the accuracy of speckle tracking compared with its real-time counterparts, at the expense of slightly higher computational demands. © 2011 IEEE
Dithering Digital Ripple Correlation Control for Photovoltaic Maximum Power Point Tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barth, C; Pilawa-Podgurski, RCN
This study demonstrates a new method for rapid and precise maximum power point tracking in photovoltaic (PV) applications using dithered PWM control. Constraints imposed by efficiency, cost, and component size limit the available PWM resolution of a power converter, and may in turn limit the MPP tracking efficiency of the PV system. In these scenarios, PWM dithering can be used to improve average PWM resolution. In this study, we present a control technique that uses ripple correlation control (RCC) on the dithering ripple, thereby achieving simultaneous fast tracking speed and high tracking accuracy. Moreover, the proposed method solves some ofmore » the practical challenges that have to date limited the effectiveness of RCC in solar PV applications. We present a theoretical derivation of the principles behind dithering digital ripple correlation control, as well as experimental results that show excellent tracking speed and accuracy with basic hardware requirements.« less
A combined analysis technique for the search for fast magnetic monopoles with the MACRO detector
NASA Astrophysics Data System (ADS)
MACRO Collaboration; Ambrosio, M.; Antolini, R.; Auriemma, G.; Bakari, D.; Baldini, A.; Barbarino, G. C.; Barish, B. C.; Battistoni, G.; Becherini, Y.; Bellotti, R.; Bemporad, C.; Bernardini, P.; Bilokon, H.; Bloise, C.; Bower, C.; Brigida, M.; Bussino, S.; Cafagna, F.; Calicchio, M.; Campana, D.; Carboni, M.; Caruso, R.; Cecchini, S.; Cei, F.; Chiarella, V.; Choudhary, B. C.; Coutu, S.; De Cataldo, G.; Dekhissi, H.; De Marzo, C.; De Mitri, I.; Derkaoui, J.; De Vincenzi, M.; DiCredico, A.; Erriquez, O.; Favuzzi, C.; Forti, C.; Fusco, P.; Giacomelli, G.; Giannini, G.; Giglietto, N.; Giorgini, M.; Grassi, M.; Grillo, A.; Guarino, F.; Gustavino, C.; Habig, A.; Heinz, R.; Iarocci, E.; Katsavounidis, E.; Katsavounidis, I.; Kearns, E.; Kim, H.; Kyriazopoulou, S.; Lamanna, E.; Lane, C.; Levin, D. S.; Lipari, P.; Longley, N. P.; Longo, M. J.; Loparco, F.; Maaroufi, F.; Mancarella, G.; Mandrioli, G.; Manzoor, S.; Margiotta, A.; Marini, A.; Martello, D.; Marzari-Chiesa, A.; Mazziotta, M. N.; Michael, D. G.; Monacelli, P.; Montaruli, T.; Monteno, M.; Mufson, S.; Musser, J.; Nicolò, D.; Nolty, R.; Orth, C.; Osteria, G.; Palamara, O.; Patera, V.; Patrizii, L.; Pazzi, R.; Peck, C. W.; Perrone, L.; Petrera, S.; Popa, V.; Reynoldson, J.; Ronga, F.; Rrhioua, A.; Satriano, C.; Scapparone, E.; Scholberg, K.; Sciubba, A.; Serra, P.; Sioli, M.; Sirri, G.; Sitta, M.; Spinelli, P.; Spinetti, M.; Spurio, M.; Steinberg, R.; Stone, J. L.; Sulak, L. R.; Surdo, A.; Tarlè, G.; Togo, V.; Vakili, M.; Walter, C. W.; Webb, R.
2002-08-01
We describe a search method for fast moving (β=v/c>5×10-3) magnetic monopoles using simultaneously the scintillator, streamer tube and track-etch subdetectors of the MACRO apparatus. The first two subdetectors are used primarily for the identification of candidates while the track-etch one is used as the final tool for their rejection or confirmation. Using this technique, a first sample of more than two years of data has been analyzed without any evidence of a magnetic monopole. We set a 90% CL upper limit to the local monopole flux of 1.5×10-15 cm-2s-1sr-1 in the velocity range 5×10-3<=β<=0.99 and for nucleon decay catalysis cross-section smaller than /~1 mb
2013-01-01
The impact of the Fast Track intervention on externalizing disorders across childhood was examined. Eight hundred-ninety-one early-starting children (69% male; 51% African American) were randomly assigned by matched sets of schools to intervention or control conditions. The 10-year intervention addressed parent behavior-management, child social cognitive skills, reading, home visiting, mentoring, and classroom curricula. Outcomes included psychiatric diagnoses after grades 3, 6, 9, and 12 for conduct disorder, oppositional defiant disorder, attention deficit hyperactivity disorder, and any externalizing disorder. Significant interaction effects between intervention and initial risk level indicated that intervention prevented the lifetime prevalence of all diagnoses, but only among those at highest initial risk, suggesting that targeted intervention can prevent externalizing disorders to promote the raising of healthy children. PMID:21291445
Initial Impact of the Fast Track Prevention Trial for Conduct Problems: II. Classroom Effects
2009-01-01
This study examined the effectiveness of the universal component of the Fast Track prevention model: the PATHS (Promoting Alternative THinking Strategies) curriculum and teacher consultation. This randomized clinical trial involved 198 intervention and 180 comparison classrooms from neighborhoods with greater than average crime in 4 U.S. locations. In the intervention schools, Grade 1 teachers delivered a 57-lesson social competence intervention focused on self-control, emotional awareness, peer relations, and problem solving. Findings indicated significant effects on peer ratings of aggression and hyperactive–disruptive behavior and observer ratings of classroom atmosphere. Quality of implementation predicted variation in assessments of classroom functioning. The results are discussed in terms of both the efficacy of universal, school-based prevention models and the need to examine comprehensive, multiyear programs. PMID:10535231
NASA Astrophysics Data System (ADS)
Leitzinger, M.; Odert, P.; Zaqarashvili, T. V.; Greimel, R.; Hanslmeier, A.; Lammer, H.
2016-11-01
We present the analysis of six nights of spectroscopic monitoring of two young and fast rotating late-type stars, namely the dMe star HK Aqr and the dG/dK star PZ Tel. On both stars, we detect absorption features reminiscent of signatures of corotating cool clouds or prominences visible in Hα. Several prominences on HK Aqr show periodic variability in the prominence tracks which follow a sinusoidal motion (indication of prominence oscillations). On PZ Tel, we could not find any periodic variability in the prominence tracks. By fitting sinusoidal functions to the prominence tracks, we derive amplitudes and periods which are similar to those of large-amplitude oscillations seen in solar prominences. In one specific event, we also derive a periodic variation of the prominence track in the Hβ spectral line which shows an anti-phase variation with the one derived for the Hα spectral line. Using these parameters and estimated mass density of a prominence on HK Aqr, we derive a minimum magnetic field strength of ˜2 G. The relatively low strength of the magnetic field is explained by the large height of this stellar prominence (≥ 0.67 stellar radii above the surface).
Fast human pose estimation using 3D Zernike descriptors
NASA Astrophysics Data System (ADS)
Berjón, Daniel; Morán, Francisco
2012-03-01
Markerless video-based human pose estimation algorithms face a high-dimensional problem that is frequently broken down into several lower-dimensional ones by estimating the pose of each limb separately. However, in order to do so they need to reliably locate the torso, for which they typically rely on time coherence and tracking algorithms. Their losing track usually results in catastrophic failure of the process, requiring human intervention and thus precluding their usage in real-time applications. We propose a very fast rough pose estimation scheme based on global shape descriptors built on 3D Zernike moments. Using an articulated model that we configure in many poses, a large database of descriptor/pose pairs can be computed off-line. Thus, the only steps that must be done on-line are the extraction of the descriptors for each input volume and a search against the database to get the most likely poses. While the result of such process is not a fine pose estimation, it can be useful to help more sophisticated algorithms to regain track or make more educated guesses when creating new particles in particle-filter-based tracking schemes. We have achieved a performance of about ten fps on a single computer using a database of about one million entries.
Integrated HI emission in galaxy groups and clusters
NASA Astrophysics Data System (ADS)
Ai, Mei; Zhu, Ming; Fu, Jian
2017-09-01
The integrated HI emission from hierarchical structures such as groups and clusters of galaxies can be detected by FAST at intermediate redshifts. Here we propose to use FAST to study the evolution of the global HI content of clusters and groups over cosmic time by measuring their integrated HI emissions. We use the Virgo Cluster as an example to estimate the detection limit of FAST, and have estimated the integration time to detect a Virgo type cluster at different redshifts (from z = 0.1 to z = 1.5).We have also employed a semi-analytic model (SAM) to simulate the evolution of HI contents in galaxy clusters. Our simulations suggest that the HI mass of a Virgo-like cluster could be 2-3 times higher and the physical size could be more than 50% smaller when redshift increases from z = 0.3 to z = 1. Thus the integration time could be reduced significantly and gas rich clusters at intermediate redshifts can be detected by FAST in less than 2 hours of integration time. For the local Universe, we have also used SAM simulations to create mock catalogs of clusters to predict the outcomes from FAST all sky surveys. Comparing with the optically selected catalogs derived by cross matching the galaxy catalogs from the SDSS survey and the ALFALFA survey, we find that the HI mass distribution of the mock catalog with 20 s of integration time agrees well with that of observations. However, the mock catalog with 120 s of integration time predicts many more groups and clusters that contain a population of low mass HI galaxies not detected by the ALFALFA survey. A future deep HI blind sky survey with FAST would be able to test such prediction and set constraints on the numerical simulation models. The observational strategy and sample selections for future FAST observations of galaxy clusters at high redshifts are also discussed.
A-Track: A new approach for detection of moving objects in FITS images
NASA Astrophysics Data System (ADS)
Atay, T.; Kaplan, M.; Kilic, Y.; Karapinar, N.
2016-10-01
We have developed a fast, open-source, cross-platform pipeline, called A-Track, for detecting the moving objects (asteroids and comets) in sequential telescope images in FITS format. The pipeline is coded in Python 3. The moving objects are detected using a modified line detection algorithm, called MILD. We tested the pipeline on astronomical data acquired by an SI-1100 CCD with a 1-meter telescope. We found that A-Track performs very well in terms of detection efficiency, stability, and processing time. The code is hosted on GitHub under the GNU GPL v3 license.
Towards an Optimal Interest Point Detector for Measurements in Ultrasound Images
NASA Astrophysics Data System (ADS)
Zukal, Martin; Beneš, Radek; Číka, Petr; Říha, Kamil
2013-12-01
This paper focuses on the comparison of different interest point detectors and their utilization for measurements in ultrasound (US) images. Certain medical examinations are based on speckle tracking which strongly relies on features that can be reliably tracked frame to frame. Only significant features (interest points) resistant to noise and brightness changes within US images are suitable for accurate long-lasting tracking. We compare three interest point detectors - Harris-Laplace, Difference of Gaussian (DoG) and Fast Hessian - and identify the most suitable one for use in US images on the basis of an objective criterion. Repeatability rate is assumed to be an objective quality measure for comparison. We have measured repeatability in images corrupted by different types of noise (speckle noise, Gaussian noise) and for changes in brightness. The Harris-Laplace detector outperformed its competitors and seems to be a sound option when choosing a suitable interest point detector for US images. However, it has to be noted that Fast Hessian and DoG detectors achieved better results in terms of processing speed.
A Globally Optimal Particle Tracking Technique for Stereo Imaging Velocimetry Experiments
NASA Technical Reports Server (NTRS)
McDowell, Mark
2008-01-01
An important phase of any Stereo Imaging Velocimetry experiment is particle tracking. Particle tracking seeks to identify and characterize the motion of individual particles entrained in a fluid or air experiment. We analyze a cylindrical chamber filled with water and seeded with density-matched particles. In every four-frame sequence, we identify a particle track by assigning a unique track label for each camera image. The conventional approach to particle tracking is to use an exhaustive tree-search method utilizing greedy algorithms to reduce search times. However, these types of algorithms are not optimal due to a cascade effect of incorrect decisions upon adjacent tracks. We examine the use of a guided evolutionary neural net with simulated annealing to arrive at a globally optimal assignment of tracks. The net is guided both by the minimization of the search space through the use of prior limiting assumptions about valid tracks and by a strategy which seeks to avoid high-energy intermediate states which can trap the net in a local minimum. A stochastic search algorithm is used in place of back-propagation of error to further reduce the chance of being trapped in an energy well. Global optimization is achieved by minimizing an objective function, which includes both track smoothness and particle-image utilization parameters. In this paper we describe our model and present our experimental results. We compare our results with a nonoptimizing, predictive tracker and obtain an average increase in valid track yield of 27 percent
Quintana-Díaz, Manuel; Fabra-Cadenas, Sara; Gómez-Ramírez, Susana; Martínez-Virto, Ana; García-Erce, José A.; Muñoz, Manuel
2016-01-01
Background Clinically significant anaemia, requiring red blood cell transfusions, is frequently observed in Emergency Departments (ED). To optimise blood product use, we developed a clinical protocol for the management of iron-deficiency anaemia in a fast-track anaemia clinic within the ED. Materials and methods From November 2010 to January 2014, patients presenting with sub-acute, moderate-to-severe anaemia (haemoglobin [Hb] <11 g/dL) and confirmed or suspected iron deficiency were referred to the fast-track anaemia clinic. Those with absolute or functional iron deficiency were given intravenous (IV) ferric carboxymaltose 500–1,000 mg/week and were reassessed 4 weeks after receiving the total iron dose. The primary study outcome was the haematological response (Hb≥12 g/dL and/or Hb increment ≥2 g/dL). Changes in blood and iron parameters, transfusion rates and IV iron-related adverse drug effects were secondary outcomes. Results Two hundred and two anaemic patients with iron deficiency (150 women/52 men; mean age, 64 years) were managed in the fast-track anaemia clinic, and received a median IV iron dose of 1,500 mg (1,000–2,000 mg). Gastro-intestinal (44%) or gynaecological (26%) bleeding was the most frequent cause of the anaemia. At follow-up (183 patients), the mean Hb increment was 3.9±2.2 g/dL; 84% of patients were classified as responders and blood and iron parameters normalised in 90%. During follow-up, 35 (17%) patients needed transfusions (2 [range: 1–3] units per patient) because they had low Hb levels, symptoms of anaemia and/or were at risk. Eight mild and one moderate, self-limited adverse drug effects were witnessed. Discussion Our data support the feasibility of a clinical protocol for management of sub-acute anaemia with IV iron in the ED. IV iron was efficacious, safe and well tolerated. Early management of anaemia will improve the use of blood products in the ED. PMID:26674819
The effect of fast and regeneration in light versus dark on regulation in the hydra-algal symbiosis
NASA Technical Reports Server (NTRS)
Bossert, P.; Slobodkin, L. B.
1983-01-01
Green hydra are able to regenerate tentacles after fast durations which cause brown, i.e., asymbiotic, hydra to fail completely, but the presence of endosymbiotic algae does not always enhance regeneration in fasted hydra. Green hydra whose nutritional state falls below some threshold, exhibit a light induced inhibition of regeneration. That is, hydra, fasted in the light, then randomly assigned to light or dark after decapitation, regenerate better in the dark. This effect of light does not appear to be present either in brown hydra or in normally green hydra from which the algae were removed. In a large strain of Chlorohydra viridissima, after fasts of intermediate duration (10 and 15 days), this light induced inhibition of regeneration is associated with an increase in the number of algae per gastric cell in regenerating hydra relative to non-regenerating controls.
Visual object tracking by correlation filters and online learning
NASA Astrophysics Data System (ADS)
Zhang, Xin; Xia, Gui-Song; Lu, Qikai; Shen, Weiming; Zhang, Liangpei
2018-06-01
Due to the complexity of background scenarios and the variation of target appearance, it is difficult to achieve high accuracy and fast speed for object tracking. Currently, correlation filters based trackers (CFTs) show promising performance in object tracking. The CFTs estimate the target's position by correlation filters with different kinds of features. However, most of CFTs can hardly re-detect the target in the case of long-term tracking drifts. In this paper, a feature integration object tracker named correlation filters and online learning (CFOL) is proposed. CFOL estimates the target's position and its corresponding correlation score using the same discriminative correlation filter with multi-features. To reduce tracking drifts, a new sampling and updating strategy for online learning is proposed. Experiments conducted on 51 image sequences demonstrate that the proposed algorithm is superior to the state-of-the-art approaches.
Caracterización y automatización mecánica de los telescopios Cherenkov de CASLEO
NASA Astrophysics Data System (ADS)
Leal, N.; Yelós, L. D.; Mancilla, A.; Maya, J.; Feres, L.; Lazarte, F.; García, B.
2017-10-01
A new automation system for the Cherenkov Telescopes at CASLEO is designed. Two rotation speeds are proposed: a fast speed for positioning and parking and a slow speed for tracking. The wind speed at El Leoncito site is used as a design parameter. In this work we present the first tests with the new setup which shows a correct performance at fast speeds.
NASA Astrophysics Data System (ADS)
Cajgfinger, Thomas; Chabanat, Eric; Dominjon, Agnes; Doan, Quang T.; Guerin, Cyrille; Houles, Julien; Barbier, Remi
2011-03-01
Nano-biophotonics applications will benefit from new fluorescent microscopy methods based essentially on super-resolution techniques (beyond the diffraction limit) on large biological structures (membranes) with fast frame rate (1000 Hz). This trend tends to push the photon detectors to the single-photon counting regime and the camera acquisition system to real time dynamic multiple-target tracing. The LUSIPHER prototype presented in this paper aims to give a different approach than those of Electron Multiplied CCD (EMCCD) technology and try to answer to the stringent demands of the new nano-biophotonics imaging techniques. The electron bombarded CMOS (ebCMOS) device has the potential to respond to this challenge, thanks to the linear gain of the accelerating high voltage of the photo-cathode, to the possible ultra fast frame rate of CMOS sensors and to the single-photon sensitivity. We produced a camera system based on a 640 kPixels ebCMOS with its acquisition system. The proof of concept for single-photon based tracking for multiple single-emitters is the main result of this paper.
The performance of the MROI fast tip-tilt correction system
NASA Astrophysics Data System (ADS)
Young, John; Buscher, David; Fisher, Martin; Haniff, Christopher; Rea, Alexander; Seneta, Eugene; Sun, Xiaowei; Wilson, Donald; Farris, Allen; Olivares, Andres
2014-07-01
The fast tip-tilt (FTT) correction system for the Magdalena Ridge Observatory Interferometer (MROI) is being developed by the University of Cambridge. The design incorporates an EMCCD camera protected by a thermal enclosure, optical mounts with passive thermal compensation, and control software running under Xenomai real-time Linux. The complete FTT system is now undergoing laboratory testing prior to being installed on the first MROI unit telescope in the fall of 2014. We are following a twin-track approach to testing the closed-loop performance: tracking tip-tilt perturbations introduced by an actuated flat mirror in the laboratory, and undertaking end-to-end simulations that incorporate realistic higher-order atmospheric perturbations. We report test results that demonstrate (a) the high stability of the entire opto-mechanical system, realized with a completely passive design; and (b) the fast tip-tilt correction performance and limiting sensitivity. Our preliminary results in both areas are close to those needed to realise the ambitious stability and sensitivity goals of the MROI which aims to match the performance of current natural guide star adaptive optics systems.
Fast Track to College Act of 2009
Rep. Kildee, Dale E. [D-MI-5
2009-03-18
House - 03/22/2010 Referred to the Subcommittee on Early Childhood, Elementary, and Secondary Education. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Li, Mengfei; Hansen, Christian; Rose, Georg
2017-09-01
Electromagnetic tracking systems (EMTS) have achieved a high level of acceptance in clinical settings, e.g., to support tracking of medical instruments in image-guided interventions. However, tracking errors caused by movable metallic medical instruments and electronic devices are a critical problem which prevents the wider application of EMTS for clinical applications. We plan to introduce a method to dynamically reduce tracking errors caused by metallic objects in proximity to the magnetic sensor coil of the EMTS. We propose a method using ramp waveform excitation based on modeling the conductive distorter as a resistance-inductance circuit. Additionally, a fast data acquisition method is presented to speed up the refresh rate. With the current approach, the sensor's positioning mean error is estimated to be 3.4, 1.3 and 0.7 mm, corresponding to a distance between the sensor and center of the transmitter coils' array of up to 200, 150 and 100 mm, respectively. The sensor pose error caused by different medical instruments placed in proximity was reduced by the proposed method to a level lower than 0.5 mm in position and [Formula: see text] in orientation. By applying the newly developed fast data acquisition method, we achieved a system refresh rate up to approximately 12.7 frames per second. Our software-based approach can be integrated into existing medical EMTS seamlessly with no change in hardware. It improves the tracking accuracy of clinical EMTS when there is a metallic object placed near the sensor coil and has the potential to improve the safety and outcome of image-guided interventions.
Fast Track to College Act of 2011
Sen. Kohl, Herb [D-WI
2011-01-25
Senate - 01/25/2011 Read twice and referred to the Committee on Health, Education, Labor, and Pensions. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Fast Track to College Act of 2009
Sen. Kohl, Herb [D-WI
2009-03-18
Senate - 03/18/2009 Read twice and referred to the Committee on Health, Education, Labor, and Pensions. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Fast Track to College Act of 2014
Sen. Coons, Christopher A. [D-DE
2014-09-18
Senate - 09/18/2014 Read twice and referred to the Committee on Health, Education, Labor, and Pensions. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Zika Virus and Complications: Questions and Answers
... mosquito breeding sites, by emptying, cleaning or covering containers that can hold even small amounts of water, ... D community and regulators to fast-track the availability of effective diagnostic tests, vaccines and medicines that ...
Locational Sensitivity Investigation on PV Hosting Capacity and Fast Track PV Screening
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, Fei; Mather, Barry; Ainsworth, Nathan
A 15% PV penetration threshold is commonly used by utilities to define photovoltaic (PV) screening methods where PV penetration is defined as the ratio of total solar PV capacity on a line section to peak load. However, this method doesn't take into account PV locational impact or feeder characteristics that could strongly change the feeder's capability to host PVs. This paper investigates the impact of PV location and phase connection type on PV hosting capacity, and then proposes a fast-track PV screening approach that leverages various PV hosting capacity metric responding to different PV locations and types. The proposed studymore » could help utilities to evaluate PV interconnection requests and also help increase the PV hosting capacity of distribution feeders without adverse impacts on system voltages.« less
Initial Impact of the Fast Track Prevention Trial for Conduct Problems: I. The High-Risk Sample
2009-01-01
Fast Track is a multisite, multicomponent preventive intervention for young children at high risk for long-term antisocial behavior. Based on a comprehensive developmental model intervention included a universal-level classroom program plus social skills training, academic tutoring, parent training, and home visiting to improve competencies and reduce problems in a high-risk group of children selected in kindergarten. At the end of Grade 1, there were moderate positive effects on children's social, emotional, and academic skills; peer interactions and social status; and conduct problems and special-education use. Parents reported less-physical discipline and greater parenting satisfaction/ease of parenting and engaged in more appropriate/consistent discipline, warmth/positive involvement, and involvement with the school. Evidence of differential intervention effects across child gender, race, site, and cohort was minimal. PMID:10535230
Success factors for reducing maternal and child mortality
Schweitzer, Julian; Bishai, David; Chowdhury, Sadia; Caramani, Daniele; Frost, Laura; Cortez, Rafael; Daelmans, Bernadette; de Francisco, Andres; Adam, Taghreed; Cohen, Robert; Alfonso, Y Natalia; Franz-Vasdeki, Jennifer; Saadat, Seemeen; Pratt, Beth Anne; Eugster, Beatrice; Bandali, Sarah; Venkatachalam, Pritha; Hinton, Rachael; Murray, John; Arscott-Mills, Sharon; Axelson, Henrik; Maliqi, Blerta; Sarker, Intissar; Lakshminarayanan, Rama; Jacobs, Troy; Jacks, Susan; Mason, Elizabeth; Ghaffar, Abdul; Mays, Nicholas; Presern, Carole; Bustreo, Flavia
2014-01-01
Abstract Reducing maternal and child mortality is a priority in the Millennium Development Goals (MDGs), and will likely remain so after 2015. Evidence exists on the investments, interventions and enabling policies required. Less is understood about why some countries achieve faster progress than other comparable countries. The Success Factors for Women’s and Children’s Health studies sought to address this knowledge gap using statistical and econometric analyses of data from 144 low- and middle-income countries (LMICs) over 20 years; Boolean, qualitative comparative analysis; a literature review; and country-specific reviews in 10 fast-track countries for MDGs 4 and 5a. There is no standard formula – fast-track countries deploy tailored strategies and adapt quickly to change. However, fast-track countries share some effective approaches in addressing three main areas to reduce maternal and child mortality. First, these countries engage multiple sectors to address crucial health determinants. Around half the reduction in child mortality in LMICs since 1990 is the result of health sector investments, the other half is attributed to investments made in sectors outside health. Second, these countries use strategies to mobilize partners across society, using timely, robust evidence for decision-making and accountability and a triple planning approach to consider immediate needs, long-term vision and adaptation to change. Third, the countries establish guiding principles that orient progress, align stakeholder action and achieve results over time. This evidence synthesis contributes to global learning on accelerating improvements in women’s and children’s health towards 2015 and beyond. PMID:25110379
Success factors for reducing maternal and child mortality.
Kuruvilla, Shyama; Schweitzer, Julian; Bishai, David; Chowdhury, Sadia; Caramani, Daniele; Frost, Laura; Cortez, Rafael; Daelmans, Bernadette; de Francisco, Andres; Adam, Taghreed; Cohen, Robert; Alfonso, Y Natalia; Franz-Vasdeki, Jennifer; Saadat, Seemeen; Pratt, Beth Anne; Eugster, Beatrice; Bandali, Sarah; Venkatachalam, Pritha; Hinton, Rachael; Murray, John; Arscott-Mills, Sharon; Axelson, Henrik; Maliqi, Blerta; Sarker, Intissar; Lakshminarayanan, Rama; Jacobs, Troy; Jack, Susan; Jacks, Susan; Mason, Elizabeth; Ghaffar, Abdul; Mays, Nicholas; Presern, Carole; Bustreo, Flavia
2014-07-01
Reducing maternal and child mortality is a priority in the Millennium Development Goals (MDGs), and will likely remain so after 2015. Evidence exists on the investments, interventions and enabling policies required. Less is understood about why some countries achieve faster progress than other comparable countries. The Success Factors for Women's and Children's Health studies sought to address this knowledge gap using statistical and econometric analyses of data from 144 low- and middle-income countries (LMICs) over 20 years; Boolean, qualitative comparative analysis; a literature review; and country-specific reviews in 10 fast-track countries for MDGs 4 and 5a. There is no standard formula--fast-track countries deploy tailored strategies and adapt quickly to change. However, fast-track countries share some effective approaches in addressing three main areas to reduce maternal and child mortality. First, these countries engage multiple sectors to address crucial health determinants. Around half the reduction in child mortality in LMICs since 1990 is the result of health sector investments, the other half is attributed to investments made in sectors outside health. Second, these countries use strategies to mobilize partners across society, using timely, robust evidence for decision-making and accountability and a triple planning approach to consider immediate needs, long-term vision and adaptation to change. Third, the countries establish guiding principles that orient progress, align stakeholder action and achieve results over time. This evidence synthesis contributes to global learning on accelerating improvements in women's and children's health towards 2015 and beyond.
[Leipzig fast-track protocol for cardio-anesthesia. Effective, safe and economical].
Häntschel, D; Fassl, J; Scholz, M; Sommer, M; Funkat, A K; Wittmann, M; Ender, J
2009-04-01
In November 2005 a complex, multimodal anesthesia fast-track protocol (FTP) was introduced for elective cardiac surgery patients in the Cardiac Center of the University of Leipzig which included changing from an opioid regime to remifentanil and postoperative treatment in a special post-anesthesia recovery and care unit. The goal was to speed up recovery times while maintaining safety and improving costs. A total of 421 patients who underwent the FTP and were treated in the special recovery room were analyzed retrospectively. These patients were compared with patients who had been treated by a standard protocol (SP) prior to instituting the FTP. Primary outcomes were time to extubation, length of stay in the intensive care unit (ICU) and treatment costs. The times to extubation were significantly shorter in the FTP group with 75 min (range 45-110 min) compared to 900 min (range 600-1140 min) in the SP group. Intensive care unit stay and hospital length of stay were also significantly shorter in the FTP group (p<0.01). The reduction of treatment costs of intensive care for FTP patients was 53.5% corresponding to savings of EUR 738 per patient in the FTP group compared with the SP group. The Leipzig fast-track protocol for cardio-anesthesia including the central elements of switching opiate therapy to remifentanil and switching patient recovery to a special post-anesthesia recovery and care unit, shortened therapy times, is safe and economically effective.
Random Breakage of a Rod into Unit Lengths
ERIC Educational Resources Information Center
Gani, Joe; Swift, Randall
2011-01-01
In this article we consider the random breakage of a rod into "L" unit elements and present a Markov chain based method that tracks intermediate breakage configurations. The probability of the time to final breakage for L = 3, 4, 5 is obtained and the method is shown to extend in principle, beyond L = 5.
Overexplicit Referent Tracking in L2 English: Strategy, Avoidance, or Myth?
ERIC Educational Resources Information Center
Ryan, Jonathon
2015-01-01
The tendency of intermediate and advanced second language speakers to underuse pronouns and zero anaphora has been characterized as a developmental stage of overexplicitness, yet little consideration has been given to whether learners create sufficient contexts for their use. This study analyzed references across eight degrees of accessibility,…
Pallavicini, Carla; Levi, Valeria; Wetzler, Diana E; Angiolini, Juan F; Benseñor, Lorena; Despósito, Marcelo A; Bruno, Luciana
2014-06-17
The cytoskeleton is involved in numerous cellular processes such as migration, division, and contraction and provides the tracks for transport driven by molecular motors. Therefore, it is very important to quantify the mechanical behavior of the cytoskeletal filaments to get a better insight into cell mechanics and organization. It has been demonstrated that relevant mechanical properties of microtubules can be extracted from the analysis of their motion and shape fluctuations. However, tracking individual filaments in living cells is extremely complex due, for example, to the high and heterogeneous background. We introduce a believed new tracking algorithm that allows recovering the coordinates of fluorescent microtubules with ∼9 nm precision in in vitro conditions. To illustrate potential applications of this algorithm, we studied the curvature distributions of fluorescent microtubules in living cells. By performing a Fourier analysis of the microtubule shapes, we found that the curvatures followed a thermal-like distribution as previously reported with an effective persistence length of ∼20 μm, a value significantly smaller than that measured in vitro. We also verified that the microtubule-associated protein XTP or the depolymerization of the actin network do not affect this value; however, the disruption of intermediate filaments decreased the persistence length. Also, we recovered trajectories of microtubule segments in actin or intermediate filament-depleted cells, and observed a significant increase of their motion with respect to untreated cells showing that these filaments contribute to the overall organization of the microtubule network. Moreover, the analysis of trajectories of microtubule segments in untreated cells showed that these filaments presented a slower but more directional motion in the cortex with respect to the perinuclear region, and suggests that the tracking routine would allow mapping the microtubule dynamical organization in cells. Copyright © 2014 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Zhang, Wei; Huang, Guangming
2015-11-15
Approaches for analyte screening have been used to aid in the fine-tuning of chemical reactions. Herein, we present a simple and straightforward analyte screening method for chemical reactions via reactive low-temperature plasma ionization mass spectrometry (reactive LTP-MS). Solution-phase reagents deposited on sample substrates were desorbed into the vapor phase by action of the LTP and by thermal desorption. Treated with LTP, both reagents reacted through a vapor phase ion/molecule reaction to generate the product. Finally, protonated reagents and products were identified by LTP-MS. Reaction products from imine formation reaction, Eschweiler-Clarke methylation and the Eberlin reaction were detected via reactive LTP-MS. Products from the imine formation reaction with reagents substituted with different functional groups (26 out of 28 trials) were successfully screened in a time of 30 s each. Besides, two short-lived reactive intermediates of Eschweiler-Clarke methylation were also detected. LTP in this study serves both as an ambient ionization source for analyte identification (including reagents, intermediates and products) and as a means to produce reagent ions to assist gas-phase ion/molecule reactions. The present reactive LTP-MS method enables fast screening for several analytes from several chemical reactions, which possesses good reagent compatibility and the potential to perform high-throughput analyte screening. In addition, with the detection of various reactive intermediates (intermediates I and II of Eschweiler-Clarke methylation), the present method would also contribute to revealing and elucidating reaction mechanisms. Copyright © 2015 John Wiley & Sons, Ltd.
Hurlock, Anna K; Wang, Kun; Takeuchi, Tomomi; Horn, Patrick J; Benning, Christoph
2018-06-19
In plant lipid metabolism, the synthesis of many intermediates or end products often appears overdetermined with multiple synthesis pathways acting in parallel. Lipid metabolism is also dynamic with interorganelle transport, turnover, and remodeling of lipids. To explore this complexity in vivo, we developed an in vivo lipid "tag and track" method. Essentially, we probed lipid metabolism in Arabidopsis thaliana by expressing a coding sequence for a fatty acid desaturase from Physcomitrella patens (Δ6D). This enzyme places a double bond after the 6 th carbon from the carboxyl end of an acyl group attached to phosphatidylcholine at its sn-2 glyceryl position providing a subtle, but easily trackable modification of the glycerolipid. Phosphatidylcholine is a central intermediate in plant lipid metabolism as it is modified and converted to precursors for other lipids throughout the plant cell. Taking advantage of the exclusive location of Δ6D in the endoplasmic reticulum (ER) and its known substrate specificity for one of the two acyl groups on phosphatidylcholine, we were able to "tag and track" the distribution of lipids within multiple compartments and their remodeling in transgenic lines of different genetic backgrounds. Key findings were the presence of ER-derived precursors in plastid phosphatidylglycerol and prevalent acyl editing of thylakoid lipids derived from multiple pathways. We expect that this "tag and track" method will serve as a tool to address several unresolved aspects of plant lipid metabolism, such as the nature and interaction of different subcellular glycerolipid pools during plant development or in response to adverse conditions. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Tian, Jingzhi; Rustum, Abu
2016-09-05
A fast static headspace gas chromatography (HS-GC) method was developed to separate all residual solvents present in commercial active pharmaceutical ingredient (API) batches of permethrin. A total of six residual solvents namely 2-methylpentane, 3-methylpentane, methylcyclopentane, n-hexane, cyclohexane and toluene were found in typical commercial batches of permethrin; and three of them are not in the list of ICH solvents. All six residual solvents were baseline separated in five minutes by the new method presented in this paper. The method was successfully validated as per International Conference on Harmonisation (ICH) guidelines. Evaluation of this method was conducted to separate 26 commonly used solvents in the manufacturing of various APIs, key intermediates of APIs and pharmaceutical excipients. The results of the evaluation demonstrated that this method can also be used as a general method to determine residual solvents in various APIs, intermediates and excipients that are used in pharmaceutical products. Copyright © 2016 Elsevier B.V. All rights reserved.
Computational tools and lattice design for the PEP-II B-Factory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai, Y.; Irwin, J.; Nosochkov, Y.
1997-02-01
Several accelerator codes were used to design the PEP-II lattices, ranging from matrix-based codes, such as MAD and DIMAD, to symplectic-integrator codes, such as TRACY and DESPOT. In addition to element-by-element tracking, we constructed maps to determine aberration strengths. Furthermore, we have developed a fast and reliable method (nPB tracking) to track particles with a one-turn map. This new technique allows us to evaluate performance of the lattices on the entire tune-plane. Recently, we designed and implemented an object-oriented code in C++ called LEGO which integrates and expands upon TRACY and DESPOT. {copyright} {ital 1997 American Institute of Physics.}
Computational tools and lattice design for the PEP-II B-Factory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai Yunhai; Irwin, John; Nosochkov, Yuri
1997-02-01
Several accelerator codes were used to design the PEP-II lattices, ranging from matrix-based codes, such as MAD and DIMAD, to symplectic-integrator codes, such as TRACY and DESPOT. In addition to element-by-element tracking, we constructed maps to determine aberration strengths. Furthermore, we have developed a fast and reliable method (nPB tracking) to track particles with a one-turn map. This new technique allows us to evaluate performance of the lattices on the entire tune-plane. Recently, we designed and implemented an object-oriented code in C++ called LEGO which integrates and expands upon TRACY and DESPOT.
Somers, Tamara J.; Keefe, Francis J.; Pells, Jennifer J.; Dixon, Kim E.; Waters, Sandra J.; Riordan, Paul A.; Blumenthal, James A.; McKee, Daphne C.; LaCaille, Lara; Tucker, Jessica M.; Schmitt, Daniel; Caldwell, David S.; Kraus, Virginia B.; Sims, Ershela L.; Shelby, Rebecca A.; Rice, John R.
2009-01-01
This study examined the degree to which pain catastrophizing and pain-related fear explain pain, psychological disability, physical disability, and walking speed in patients with osteoarthritis (OA) of the knee. Participants in this study were 106 individuals diagnosed as having OA of at least one knee, who reported knee pain persisting six months or longer. Results suggest that pain catastrophizing explained a significant proportion (all P's ≤ 0.05) of variance in measures of pain (partial r2 [pr2] = 0.10), psychological disability (pr2 = 0.20), physical disability (pr2 = 0.11), and gait velocity at normal (pr2 = 0.04), fast (pr2 = 0.04), and intermediate speeds (pr2 = 0.04). Pain-related fear explained a significant proportion of the variance in measures of psychological disability (pr2 = 0.07) and walking at a fast speed (pr2 = 0.05). Pain cognitions, particularly pain catastrophizing, appear to be important variables in understanding pain, disability, and walking at normal, fast, and intermediate speeds in knee OA patients. Clinicians interested in understanding variations in pain and disability in this population may benefit by expanding the focus of their inquiries beyond traditional medical and demographic variables to include an assessment of pain catastrophizing and pain-related fear. PMID:19041218
Fast, Capacious Disk Memory Device
NASA Technical Reports Server (NTRS)
Muller, Ronald M.
1990-01-01
Device for recording digital data on, and playing back data from, memory disks has high recording or playback rate and utilizes available recording area more fully. Two disks, each with own reading/writing head, used to record data at same time. Head on disk A operates on one of tracks numbered from outside in; head on disk B operates on track of same number in sequence from inside out. Underlying concept of device applicable to magnetic or optical disks.
The use of integrated focal plane array technologies in laser microsatellite networks
NASA Astrophysics Data System (ADS)
Arnon, Shlomi
2004-10-01
Clustering micro satellites in cooperative fly formation constellations leads to high-performance space systems. The only way to achieve high-speed communication between the satellites is by a laser beam with a narrow divergence angle. In order to make the communication successful three types of focal plane detector arrays are required in the communication terminal: acquisition, tracking and communication detector arrays. The acquisition detector array is used to acquire the neighbor satellite using a wide field-of-view telescope. The tracking detector provides fast, real time and accurate direction location of the neighbor satellite. Based on the information from the acquisition and tracking detectors the receiver and transmitter maintain line of sight. The development of large, fast and very sensitive focal plane detector arrays makes it possible to implement the acquisition, tracking and communication with only one focal plane detector array. By doing so it is possible to reduce dramatically the size, weight, and cost of the optics and electronics which leads to lightweight communication terminals. As a result, the satellites are smaller and lighter, which reduces the space mission cost and increases the booster efficiency. In this paper we will present an overview of the concept of integrated focal plane arrays for laser satellite communication. We also present simulation results based on real system parameters and compare different implementation options.
NASA Astrophysics Data System (ADS)
Williamson, Andrew; Arnold, Neil; Banwell, Alison; Willis, Ian
2017-04-01
Supraglacial lakes (SGLs) on the Greenland Ice Sheet (GrIS) influence ice dynamics if draining rapidly by hydrofracture, which can occur in under 24 hours. MODerate-resolution Imaging Spectroradiometer (MODIS) data are often used to investigate SGLs, including calculating SGL area changes through time, but no existing work presents a method that tracks changes in individual (and total) SGL volume in MODIS imagery over a melt season. Here, we present such a method. First, we tested three automated approaches to derive SGL areas from MODIS imagery by comparing calculated areas for the Paakitsoq and Store Glacier regions in West Greenland with areas derived from Landsat-8 (LS8) images. Second, we applied a physically-based depth-calculation algorithm to the pixels within the SGL boundaries from the best performing method, and validated the resultant depths with those calculated using the same method applied to LS8 imagery. Our results indicated that SGL areas are most accurately generated using dynamic thresholding of MODIS band 1 (red) with a 0.640 threshold value. Calculated SGL area, depth and volume values from MODIS were closely comparable to those derived from LS8. The best performing area- and depth-detection methods were then incorporated into a Fully Automated SGL Tracking ("FAST") algorithm that tracks individual SGLs between successive MODIS images. It identified 43 (Paakitsoq) and 19 (Store Glacier) rapidly draining SGLs during 2014, representing 21% and 15% of the respective total SGL populations, including some clusters of rapidly draining SGLs. We found no relationship between the water volumes contained within these rapidly draining SGLs and the ice thicknesses beneath them, indicating that a critical water volume linearly related to ice thickness cannot explain the incidence of rapid drainage. The FAST algorithm, which we believe to be the most comprehensive SGL tracking algorithm developed to date, has the potential to investigate statistical relationships between SGL areas, volumes and drainage events over wide areas of the GrIS, and over multiple seasons. It could also allow further insights into factors that may trigger rapid SGL drainage.
FAST TRACK COMMUNICATION The Bel-Robinson tensor for topologically massive gravity
NASA Astrophysics Data System (ADS)
Deser, S.; Franklin, J.
2011-02-01
We construct, and establish the (covariant) conservation of, a 4-index 'super stress tensor' for topologically massive gravity. Separately, we discuss its invalidity in quadratic curvature models and suggest a generalization.
1999 Florida Freight Stakeholders Task Force Report
DOT National Transportation Integrated Search
1999-11-01
The Florida Freight Stakeholders Task Force was organized in 1998 as a result of the Governor's Transportation Summit to address two principal objectives: (1) to identify, prioritize and recommend freight transportation projects for fast track fundin...
Just Add Water and Stir. Graduate Chemistry Laboratory, Stony Brook
ERIC Educational Resources Information Center
Yee, Roger
1974-01-01
Using traditional building materials and a fast-track recipe, the architects, acting as construction manager, completed the Graduate Chemistry Laboratory at Stony Brook, New York, two full years ahead of schedule. (Author/MF)
Analysis of a spatial tracking subsystem for optical communications
NASA Technical Reports Server (NTRS)
Win, Moe Z.; Chen, CHIEN-C.
1992-01-01
Spatial tracking plays a very critical role in designing optical communication systems because of the small angular beamwidth associated with the optical signal. One possible solution for spatial tracking is to use a nutating mirror which dithers the incoming beam at a rate much higher than the mechanical disturbances. A power detector then senses the change in detected power as the signal is reflected off the nutating mirror. This signal is then correlated with the nutator driver signals to obtain estimates of the azimuth and elevation tracking signals to control the fast scanning mirrors. A theoretical analysis is performed for a spatial tracking system using a nutator disturbed by shot noise and mechanical vibrations. Contributions of shot noise and mechanical vibrations to the total tracking error variance are derived. Given the vibration spectrum and the expected signal power, there exists an optimal amplitude for the nutation which optimizes the receiver performance. The expected performance of a nutator based system is estimated based on the choice of nutation amplitude.
Convolutional networks for vehicle track segmentation
NASA Astrophysics Data System (ADS)
Quach, Tu-Thach
2017-10-01
Existing methods to detect vehicle tracks in coherent change detection images, a product of combining two synthetic aperture radar images taken at different times of the same scene, rely on simple and fast models to label track pixels. These models, however, are unable to capture natural track features, such as continuity and parallelism. More powerful but computationally expensive models can be used in offline settings. We present an approach that uses dilated convolutional networks consisting of a series of 3×3 convolutions to segment vehicle tracks. The design of our networks considers the fact that remote sensing applications tend to operate in low power and have limited training data. As a result, we aim for small and efficient networks that can be trained end-to-end to learn natural track features entirely from limited training data. We demonstrate that our six-layer network, trained on just 90 images, is computationally efficient and improves the F-score on a standard dataset to 0.992, up from 0.959 obtained by the current state-of-the-art method.
Nonlinear dynamics support a linear population code in a retinal target-tracking circuit.
Leonardo, Anthony; Meister, Markus
2013-10-23
A basic task faced by the visual system of many organisms is to accurately track the position of moving prey. The retina is the first stage in the processing of such stimuli; the nature of the transformation here, from photons to spike trains, constrains not only the ultimate fidelity of the tracking signal but also the ease with which it can be extracted by other brain regions. Here we demonstrate that a population of fast-OFF ganglion cells in the salamander retina, whose dynamics are governed by a nonlinear circuit, serve to compute the future position of the target over hundreds of milliseconds. The extrapolated position of the target is not found by stimulus reconstruction but is instead computed by a weighted sum of ganglion cell outputs, the population vector average (PVA). The magnitude of PVA extrapolation varies systematically with target size, speed, and acceleration, such that large targets are tracked most accurately at high speeds, and small targets at low speeds, just as is seen in the motion of real prey. Tracking precision reaches the resolution of single photoreceptors, and the PVA algorithm performs more robustly than several alternative algorithms. If the salamander brain uses the fast-OFF cell circuit for target extrapolation as we suggest, the circuit dynamics should leave a microstructure on the behavior that may be measured in future experiments. Our analysis highlights the utility of simple computations that, while not globally optimal, are efficiently implemented and have close to optimal performance over a limited but ethologically relevant range of stimuli.
NASA Astrophysics Data System (ADS)
Suárez, B.; Rodriguez, P.; Vázquez, M.; Fernández, I.
2012-01-01
Vehicle-track interaction for a new resilient slab track designed to reduce noise and vibration levels was analysed, in order to assess the derailment risk on a curved track when encountering a broken rail. Sensitivity of the rail support spacing of the relative position of the rail breakage between two adjacent rail supports and of running speed were analysed for two different elasticities of the rail fastening system. In none of the cases analysed was observed an appreciable difference between either of the elastic systems. As was expected, the most unfavourable situations were those with greater rail support spacing and those with greater distance from the breakage to the nearest rail support, although in none of the simulations performed did a derailment occur when running over the broken rail. When varying the running speed, the most favourable condition was obtained for an intermediate speed, due to the superposition of two antagonistic effects.
NASA Astrophysics Data System (ADS)
Neher, Peter F.; Stieltjes, Bram; Reisert, Marco; Reicht, Ignaz; Meinzer, Hans-Peter; Fritzsche, Klaus H.
2012-02-01
Fiber tracking algorithms yield valuable information for neurosurgery as well as automated diagnostic approaches. However, they have not yet arrived in the daily clinical practice. In this paper we present an open source integration of the global tractography algorithm proposed by Reisert et.al.1 into the open source Medical Imaging Interaction Toolkit (MITK) developed and maintained by the Division of Medical and Biological Informatics at the German Cancer Research Center (DKFZ). The integration of this algorithm into a standardized and open development environment like MITK enriches accessibility of tractography algorithms for the science community and is an important step towards bringing neuronal tractography closer to a clinical application. The MITK diffusion imaging application, downloadable from www.mitk.org, combines all the steps necessary for a successful tractography: preprocessing, reconstruction of the images, the actual tracking, live monitoring of intermediate results, postprocessing and visualization of the final tracking results. This paper presents typical tracking results and demonstrates the steps for pre- and post-processing of the images.
Balancing fast-rotating parts of hand-held machine drive
NASA Astrophysics Data System (ADS)
Korotkov, V. S.; Sicora, E. A.; Nadeina, L. V.; Yongzheng, Wang
2018-03-01
The article considers the issues related to the balancing of fast rotating parts of the hand-held machine drive including a wave transmission with intermediate rolling elements, which is constructed on the basis of the single-phase collector motor with a useful power of 1 kW and a nominal rotation frequency of 15000 rpm. The forms of balancers and their location are chosen. The method of balancing is described. The scheme for determining of residual unbalance in two correction planes is presented. Measurement results are given in tables.
Track Everything: Limiting Prior Knowledge in Online Multi-Object Recognition.
Wong, Sebastien C; Stamatescu, Victor; Gatt, Adam; Kearney, David; Lee, Ivan; McDonnell, Mark D
2017-10-01
This paper addresses the problem of online tracking and classification of multiple objects in an image sequence. Our proposed solution is to first track all objects in the scene without relying on object-specific prior knowledge, which in other systems can take the form of hand-crafted features or user-based track initialization. We then classify the tracked objects with a fast-learning image classifier, that is based on a shallow convolutional neural network architecture and demonstrate that object recognition improves when this is combined with object state information from the tracking algorithm. We argue that by transferring the use of prior knowledge from the detection and tracking stages to the classification stage, we can design a robust, general purpose object recognition system with the ability to detect and track a variety of object types. We describe our biologically inspired implementation, which adaptively learns the shape and motion of tracked objects, and apply it to the Neovision2 Tower benchmark data set, which contains multiple object types. An experimental evaluation demonstrates that our approach is competitive with the state-of-the-art video object recognition systems that do make use of object-specific prior knowledge in detection and tracking, while providing additional practical advantages by virtue of its generality.
Dynamic grid refinement for partial differential equations on parallel computers
NASA Technical Reports Server (NTRS)
Mccormick, S.; Quinlan, D.
1989-01-01
The fast adaptive composite grid method (FAC) is an algorithm that uses various levels of uniform grids to provide adaptive resolution and fast solution of PDEs. An asynchronous version of FAC, called AFAC, that completely eliminates the bottleneck to parallelism is presented. This paper describes the advantage that this algorithm has in adaptive refinement for moving singularities on multiprocessor computers. This work is applicable to the parallel solution of two- and three-dimensional shock tracking problems.
Simplified fast neutron dosimeter
Sohrabi, Mehdi
1979-01-01
Direct fast-neutron-induced recoil and alpha particle tracks in polycarbonate films may be enlarged for direct visual observation and automated counting procedures employing electrochemical etching techniques. Electrochemical etching is, for example, carried out in a 28% KOH solution at room temperature by applying a 2000 V peak-to-peak voltage at 1 kHz frequency. Such recoil particle amplification can be used for the detection of wide neutron dose ranges from 1 mrad. to 1000 rads. or higher, if desired.
2015-03-01
Through the use of a sophisticated modeling technique, investigators at the University of Cincinnati have found that the creation of a so-called "flex track" that includes beds that can be assigned to either high-acuity or Iow-acuity- patients has the potential to lower mean wait times for patients when it is i added to the traditional fast-track and high-acuity areas of a 50-bed ED that sees 85,000 patients per year. Investigators used discrete-event simulation to model the patient flow and characteristics of the ED at the University of Cincinnati Medical Center, and to test out various operational scenarios without disrupting real-world operations. The investigators concluded that patient wait times were lowest when three flex beds were appropriated from the 10-bed fast track area of the EDs. In light of the results, three flex rooms are being incorporated into a newly remodeled ED scheduled for completion laterthis spring. Investigators suggest the modeling technique could be useful to other EDs interested in optimizing their operational plans. Further, they suggest that ED administrators consider ways to introduce flexibility into departments that are now more rigidly divided between high- and low-acuity areas.
Sustainable High-Potential Career Development: A Resource-Based View.
ERIC Educational Resources Information Center
Iles, Paul
1997-01-01
In the current economic climate, fast-track career models pose problems for individuals and organizations. An alternative model uses a resource-based view of the company and principles of sustainable development borrowed from environmentalism. (SK)
NASA Astrophysics Data System (ADS)
Parracino, Stefano; Santoro, Simone; Maio, Giovanni; Nuvoli, Marcello; Aiuppa, Alessandro; Fiorani, Luca
2017-04-01
Carbon dioxide (CO2) is considered a precursor gas of volcanic eruptions by volcanologists. Monitoring the anomalous release of this parameter, we can retrieve useful information for the mitigation of volcanic hazards, such as for air traffic security. From a dataset collected during the Stromboli volcano field campaign, an assessment of the wind speed, in both horizontal and vertical paths, performing a fast tracking of this parameter was retrieved. This was determined with a newly designed shot-per-shot differential absorption LiDAR system operated in the near-infrared spectral region due to the simultaneous reconstruction of CO2 concentrations and wind speeds, using the same sample of LiDAR returns. A correlation method was used for the wind speed retrieval in which the transport of the spatial inhomogeneities of the aerosol backscattering coefficient, along the optical path of the system, was analyzed.
Fast cine-magnetic resonance imaging point tracking for prostate cancer radiation therapy planning
NASA Astrophysics Data System (ADS)
Dowling, J.; Dang, K.; Fox, Chris D.; Chandra, S.; Gill, Suki; Kron, T.; Pham, D.; Foroudi, F.
2014-03-01
The analysis of intra-fraction organ motion is important for improving the precision of radiation therapy treatment delivery. One method to quantify this motion is for one or more observers to manually identify anatomic points of interest (POIs) on each slice of a cine-MRI sequence. However this is labour intensive and inter- and intra- observer variation can introduce uncertainty. In this paper a fast method for non-rigid registration based point tracking in cine-MRI sagittal and coronal series is described which identifies POIs in 0.98 seconds per sagittal slice and 1.35 seconds per coronal slice. The manual and automatic points were highly correlated (r>0.99, p<0.001) for all organs and the difference generally less than 1mm. For prostate planning peristalsis and rectal gas can result in unpredictable out of plane motion, suggesting the results may require manual verification.
The value of materials R&D in the fast track development of fusion power
NASA Astrophysics Data System (ADS)
Ward, D. J.; Taylor, N. P.; Cook, I.
2007-08-01
The objective of the international fusion program is the creation of power plants with attractive safety and environmental features and viable economics. There is a range of possible plants that can meet these objectives, as studied for instance in the recent EU studies of power plant concepts. All of the concepts satisfy safety and environmental objectives but the economic performance is interpreted differently in different world regions according to the perception of future energy markets. This leads to different materials performance targets and the direction and timescales of the materials development programme needed to meet those targets. In this paper, the implications for materials requirements of a fast track approach to fusion development are investigated. This includes a quantification of the overall benefits of more advanced materials: including the effect of trading off an extended development time against a reduced cost of electricity for resulting power plants.
Health Preemption Behind Closed Doors: Trade Agreements and Fast-Track Authority
Crosbie, Eric; Gonzalez, Mariaelena
2014-01-01
Noncommunicable diseases result from consuming unhealthy products, including tobacco, which are promoted by transnational corporations. The tobacco industry uses preemption to block or reverse tobacco control policies. Preemption removes authority from jurisdictions where tobacco companies’ influence is weak and transfers it to jurisdictions where they have an advantage. International trade agreements relocate decisions about tobacco control policy to venues where there is little opportunity for public scrutiny, participation, and debate. Tobacco companies are using these agreements to preempt domestic authority over tobacco policy. Other transnational corporations that profit by promoting unhealthy foods could do the same. “Fast-track authority,” in which Congress cedes ongoing oversight authority to the President, further distances the public from the debate. With international agreements binding governments to prioritize trade over health, transparency and public oversight of the trade negotiation process is necessary to safeguard public health interests. PMID:25033124
Tracking weight change, insulin resistance, stress, and aerobic fitness over 4 years of college.
Hopper, Mari K; Moninger, Shana Lynn
2017-01-01
To determine if weight gain is accompanied by development of insulin resistance (IR) during 4 years in college. Two cohorts of college students were enrolled in fall semesters 2009 and 2010 and tracked for 4 years. Following a 12-hour fast, subjects reported for measurement of body mass index (BMI), perceived stress (PSS), aerobic fitness, and blood glucose, insulin, and lipids. In the first year, 33% of subjects were overweight or obese, and 20% were hyperinsulinemic. Year 4 had 29 remaining subjects with disproportionate attrition of overweight and obese individuals. Just over half the subjects gained weight (WI), whereas nearly 30% lost considerable amounts (WD). WD showed significant decline in fasting insulin, low-density lipoprotein (LDL) cholesterol, and PSS from year 1. WI was primarily highly fit men who did not demonstrate increased IR. WI was not associated with IR over 4 years of college.
Potential Application of a Graphical Processing Unit to Parallel Computations in the NUBEAM Code
NASA Astrophysics Data System (ADS)
Payne, J.; McCune, D.; Prater, R.
2010-11-01
NUBEAM is a comprehensive computational Monte Carlo based model for neutral beam injection (NBI) in tokamaks. NUBEAM computes NBI-relevant profiles in tokamak plasmas by tracking the deposition and the slowing of fast ions. At the core of NUBEAM are vector calculations used to track fast ions. These calculations have recently been parallelized to run on MPI clusters. However, cost and interlink bandwidth limit the ability to fully parallelize NUBEAM on an MPI cluster. Recent implementation of double precision capabilities for Graphical Processing Units (GPUs) presents a cost effective and high performance alternative or complement to MPI computation. Commercially available graphics cards can achieve up to 672 GFLOPS double precision and can handle hundreds of thousands of threads. The ability to execute at least one thread per particle simultaneously could significantly reduce the execution time and the statistical noise of NUBEAM. Progress on implementation on a GPU will be presented.
Health preemption behind closed doors: trade agreements and fast-track authority.
Crosbie, Eric; Gonzalez, Mariaelena; Glantz, Stanton A
2014-09-01
Noncommunicable diseases result from consuming unhealthy products, including tobacco, which are promoted by transnational corporations. The tobacco industry uses preemption to block or reverse tobacco control policies. Preemption removes authority from jurisdictions where tobacco companies' influence is weak and transfers it to jurisdictions where they have an advantage. International trade agreements relocate decisions about tobacco control policy to venues where there is little opportunity for public scrutiny, participation, and debate. Tobacco companies are using these agreements to preempt domestic authority over tobacco policy. Other transnational corporations that profit by promoting unhealthy foods could do the same. "Fast-track authority," in which Congress cedes ongoing oversight authority to the President, further distances the public from the debate. With international agreements binding governments to prioritize trade over health, transparency and public oversight of the trade negotiation process is necessary to safeguard public health interests.
Electric eels use high-voltage to track fast-moving prey
Catania, Kenneth C.
2015-01-01
Electric eels (Electrophorus electricus) are legendary for their ability to incapacitate fish, humans, and horses with hundreds of volts of electricity. The function of this output as a weapon has been obvious for centuries but its potential role for electroreception has been overlooked. Here it is shown that electric eels use high-voltage simultaneously as a weapon and for precise and rapid electrolocation of fast-moving prey and conductors. Their speed, accuracy, and high-frequency pulse rate are reminiscent of bats using a ‘terminal feeding buzz' to track insects. Eel's exhibit ‘sensory conflict' when mechanosensory and electrosensory cues are separated, striking first toward mechanosensory cues and later toward conductors. Strikes initiated in the absence of conductors are aborted. In addition to providing new insights into the evolution of strongly electric fish and showing electric eels to be far more sophisticated than previously described, these findings reveal a trait with markedly dichotomous functions. PMID:26485580
The design of a fast Level 1 Track trigger for the ATLAS High Luminosity Upgrade
NASA Astrophysics Data System (ADS)
Miller Allbrooke, Benedict Marc; ATLAS Collaboration
2017-10-01
The ATLAS experiment at the high-luminosity LHC will face a five-fold increase in the number of interactions per collision relative to the ongoing Run 2. This will require a proportional improvement in rejection power at the earliest levels of the detector trigger system, while preserving good signal efficiency, due to the increase in the likelihood of individual trigger thresholds being passed as a result of pile-up related activity. One critical aspect of this improvement will be the implementation of precise track reconstruction, through which sharper turn-on curves, b-tagging and tau-tagging techniques can in principle be implemented. The challenge of such a project comes in the development of a fast, precise custom electronic device integrated in the hardware-based first trigger level of the experiment, with repercussions propagating as far as the detector read-out philosophy.
Distinguishing the rates of gene activation from phenotypic variations.
Chen, Ye; Lv, Cheng; Li, Fangting; Li, Tiejun
2015-06-18
Stochastic genetic switching driven by intrinsic noise is an important process in gene expression. When the rates of gene activation/inactivation are relatively slow, fast, or medium compared with the synthesis/degradation rates of mRNAs and proteins, the variability of protein and mRNA levels may exhibit very different dynamical patterns. It is desirable to provide a systematic approach to identify their key dynamical features in different regimes, aiming at distinguishing which regime a considered gene regulatory network is in from their phenotypic variations. We studied a gene expression model with positive feedbacks when genetic switching rates vary over a wide range. With the goal of providing a method to distinguish the regime of the switching rates, we first focus on understanding the essential dynamics of gene expression system in different cases. In the regime of slow switching rates, we found that the effective dynamics can be reduced to independent evolutions on two separate layers corresponding to gene activation and inactivation states, and the transitions between two layers are rare events, after which the system goes mainly along deterministic ODE trajectories on a particular layer to reach new steady states. The energy landscape in this regime can be well approximated by using Gaussian mixture model. In the regime of intermediate switching rates, we analyzed the mean switching time to investigate the stability of the system in different parameter ranges. We also discussed the case of fast switching rates from the viewpoint of transition state theory. Based on the obtained results, we made a proposal to distinguish these three regimes in a simulation experiment. We identified the intermediate regime from the fact that the strength of cellular memory is lower than the other two cases, and the fast and slow regimes can be distinguished by their different perturbation-response behavior with respect to the switching rates perturbations. We proposed a simulation experiment to distinguish the slow, intermediate and fast regimes, which is the main point of our paper. In order to achieve this goal, we systematically studied the essential dynamics of gene expression system when the switching rates are in different regimes. Our theoretical understanding provides new insights on the gene expression experiments.
An Improved Perturb and Observe Algorithm for Photovoltaic Motion Carriers
NASA Astrophysics Data System (ADS)
Peng, Lele; Xu, Wei; Li, Liming; Zheng, Shubin
2018-03-01
An improved perturbation and observation algorithm for photovoltaic motion carriers is proposed in this paper. The model of the proposed algorithm is given by using Lambert W function and tangent error method. Moreover, by using matlab and experiment of photovoltaic system, the tracking performance of the proposed algorithm is tested. And the results demonstrate that the improved algorithm has fast tracking speed and high efficiency. Furthermore, the energy conversion efficiency by the improved method has increased by nearly 8.2%.
Proportional plus integral MIMO controller for regulation and tracking with anti-wind-up features
DOE Office of Scientific and Technical Information (OSTI.GOV)
Puleston, P.F.; Mantz, R.J.
1993-11-01
A proportional plus integral matrix control structure for MIMO systems is proposed. Based on a standard optimal control structure with integral action, it permits a greater degree of independence of the design and tuning of the regulating and tracking features, without considerably increasing the controller complexity. Fast recovery from load disturbances is achieved, while large overshoots associated with set-point changes and reset wind-up problems can be reduced. A simple effective procedure for practical tuning is introduced.
Human ethology: age and sex differences in mall walking.
Hangland, A; Cimbalo, R S
1997-12-01
Well-controlled experimental research has examined the biomechanical aspects of walking in homo sapiens on a track. The research reported here also examined cadence, velocity, and stride length for estimated ages ranging from 15 to over 55 years but in a shopping mall. Women at all ages walked faster than men in the mall setting which was opposite to what was found in the track research. Apparently context may influence how fast people walk. Hunter-gatherer differences could explain these results.
Postural Control During Cascade Ball Juggling: Effects of Expertise and Base of Support.
Rodrigues, Sérgio T; Polastri, Paula F; Gotardi, Gisele C; Aguiar, Stefane A; Mesaros, Marcelo R; Pestana, Mayara B; Barbieri, Fabio A
2016-08-01
Cascade ball juggling is a complex perceptual motor skill which requires efficient postural stabilization. The aim of this study was to investigate effects of experience (expert and intermediate groups) and foot distance (wide and narrow stances) on body sway of jugglers during three ball cascade juggling. A total of 10 expert jugglers and 11 intermediate jugglers participated in this study. Participants stood barefoot on the force plate (some participants wore a gaze tracking system), with feet maintained in wide and narrow conditions and performed three 40-seconds trials of the three-ball juggling task. Dependent variables were sway mean velocity, amplitude, mean frequency, number of ball cycles, fixation number, mean duration and its variability, and area of gaze displacement. Two-way analyses of variance with factors for group and condition were conducted. Experts' body sway was characterized by lower velocity and smaller amplitude as compared to intermediate group. Interestingly, the more challenging (narrow) basis of support caused significant attenuation in body sway only for the intermediate group. These data suggest that expertise in cascade juggling was associated with refined postural control. © The Author(s) 2016.
Towards Kilo-Hertz 6-DoF Visual Tracking Using an Egocentric Cluster of Rolling Shutter Cameras.
Bapat, Akash; Dunn, Enrique; Frahm, Jan-Michael
2016-11-01
To maintain a reliable registration of the virtual world with the real world, augmented reality (AR) applications require highly accurate, low-latency tracking of the device. In this paper, we propose a novel method for performing this fast 6-DOF head pose tracking using a cluster of rolling shutter cameras. The key idea is that a rolling shutter camera works by capturing the rows of an image in rapid succession, essentially acting as a high-frequency 1D image sensor. By integrating multiple rolling shutter cameras on the AR device, our tracker is able to perform 6-DOF markerless tracking in a static indoor environment with minimal latency. Compared to state-of-the-art tracking systems, this tracking approach performs at significantly higher frequency, and it works in generalized environments. To demonstrate the feasibility of our system, we present thorough evaluations on synthetically generated data with tracking frequencies reaching 56.7 kHz. We further validate the method's accuracy on real-world images collected from a prototype of our tracking system against ground truth data using standard commodity GoPro cameras capturing at 120 Hz frame rate.
Visual tracking using objectness-bounding box regression and correlation filters
NASA Astrophysics Data System (ADS)
Mbelwa, Jimmy T.; Zhao, Qingjie; Lu, Yao; Wang, Fasheng; Mbise, Mercy
2018-03-01
Visual tracking is a fundamental problem in computer vision with extensive application domains in surveillance and intelligent systems. Recently, correlation filter-based tracking methods have shown a great achievement in terms of robustness, accuracy, and speed. However, such methods have a problem of dealing with fast motion (FM), motion blur (MB), illumination variation (IV), and drifting caused by occlusion (OCC). To solve this problem, a tracking method that integrates objectness-bounding box regression (O-BBR) model and a scheme based on kernelized correlation filter (KCF) is proposed. The scheme based on KCF is used to improve the tracking performance of FM and MB. For handling drift problem caused by OCC and IV, we propose objectness proposals trained in bounding box regression as prior knowledge to provide candidates and background suppression. Finally, scheme KCF as a base tracker and O-BBR are fused to obtain a state of a target object. Extensive experimental comparisons of the developed tracking method with other state-of-the-art trackers are performed on some of the challenging video sequences. Experimental comparison results show that our proposed tracking method outperforms other state-of-the-art tracking methods in terms of effectiveness, accuracy, and robustness.
NASA Astrophysics Data System (ADS)
Kubes, P.; Paduch, M.; Sadowski, M. J.; Cikhardt, J.; Cikhardtova, B.; Klir, D.; Kravarik, J.; Munzar, V.; Rezac, K.; Zielinska, E.; Skladnik-Sadowska, E.; Szymaszek, A.; Tomaszewski, K.; Zaloga, D.
2018-01-01
This paper considers regions of a fast deuteron production in a correlation with an evolution of ordered structures inside a pinch column of a mega-ampere plasma focus discharge. Ion pinhole cameras equipped with plastic PM-355 track-detectors recorded fast deuterons escaping in the downstream and other directions (up to 60° to the z-axis). Time-integrated ion images made it possible to estimate sources of the deuteron acceleration at the known magnetic field and deuteron energy values. The images of the fast deuterons emitted in the solid angle ranging from 0° to 4° showed two forms: central spots and circular images. The spots of 1-2 cm in diameter were produced by deuterons from the central pinch regions. The circular-shaped images of a radius above 3 cm (or their parts) were formed by deuterons from the region surrounding the dense pinch column. The ion pinhole cameras placed at angles above 20° to the z-axis recorded the ion spots only, and the ring-images were missing. The central region of the deuteron acceleration could be associated mainly with plasmoids, and the circular images could be connected with ring-shaped regions of the radius corresponding to tops of the plasma lobules outside the dense pinch column. The deuteron tracks forming ring-shaped images of a smaller (0.5-1) cm radius could be produced by deflections of the fast deuterons, which were caused by a magnetic field inside the dense pinch column.
Cho, Kyung-Sang; Heo, Keun; Baik, Chan-Wook; Choi, Jun Young; Jeong, Heejeong; Hwang, Sungwoo; Lee, Sang Yeol
2017-10-10
We report color-selective photodetection from intermediate, monolayered, quantum dots buried in between amorphous-oxide semiconductors. The proposed active channel in phototransistors is a hybrid configuration of oxide-quantum dot-oxide layers, where the gate-tunable electrical property of silicon-doped, indium-zinc-oxide layers is incorporated with the color-selective properties of quantum dots. A remarkably high detectivity (8.1 × 10 13 Jones) is obtained, along with three major findings: fast charge separation in monolayered quantum dots; efficient charge transport through high-mobility oxide layers (20 cm 2 V -1 s -1 ); and gate-tunable drain-current modulation. Particularly, the fast charge separation rate of 3.3 ns -1 measured with time-resolved photoluminescence is attributed to the intermediate quantum dots buried in oxide layers. These results facilitate the realization of efficient color-selective detection exhibiting a photoconductive gain of 10 7 , obtained using a room-temperature deposition of oxide layers and a solution process of quantum dots. This work offers promising opportunities in emerging applications for color detection with sensitivity, transparency, and flexibility.The development of highly sensitive photodetectors is important for image sensing and optical communication applications. Cho et al., report ultra-sensitive photodetectors based on monolayered quantum dots buried in between amorphous-oxide semiconductors and demonstrate color-detecting logic gates.
Shock and Rarefaction Waves in a Heterogeneous Mantle
NASA Astrophysics Data System (ADS)
Jordan, J.; Hesse, M. A.
2012-12-01
We explore the effect of heterogeneities on partial melting and melt migration during active upwelling in the Earth's mantle. We have constructed simple, explicit nonlinear models in one dimension to examine heterogeneity and its dynamic affects on porosity, temperature and the magnesium number in a partially molten, porous medium comprised of olivine. The composition of the melt and solid are defined by a closed, binary phase diagram for a simplified, two-component olivine system. The two-component solid solution is represented by a phase loop where concentrations 0 and 1 to correspond to fayalite and forsterite, respectively. For analysis, we examine an advective system with a Riemann initial condition. Chromatographic tools and theory have primarily been used to track large, rare earth elements as tracers. In our case, we employ these theoretical tools to highlight the importance of the magnesium number, enthalpy and overall heterogeneity in the dynamics of melt migration. We calculate the eigenvectors and eigenvalues in the concentration-enthalpy space in order to glean the characteristics of the waves emerging the Riemann step. Analysis on Riemann problems of this nature shows us that the composition-enthalpy waves can be represented by self-similar solutions. The eigenvalues of the composition-enthalpy system represent the characteristic wave propagation speeds of the compositions and enthalpy through the domain. Furthermore, the corresponding eigenvectors are the directions of variation, or ``pathways," in concentration-enthalpy space that the characteristic waves follow. In the two-component system, the Riemann problem yields two waves connected by an intermediate concentration-enthalpy state determined by the intersections of the integral curves of the eigenvectors emanating from both the initial and boundary states. The first wave, ``slow path," and second wave, ``fast path," follow the aformentioned pathways set by the eigenvectors. The slow path wave has a zero eigenvalue, corresponding to a wave speed of zero, which preserves a residual imprint of the initial condition. Freezing fronts textemdash those that result in a negative change in porositytextemdash feature fast path waves that travel as shocks, whereas the fast path waves of melting fronts travel as spreading, rarefaction waves.
Dogan, Kemal; Kraaij, Linda; Aarts, Edo O; Koehestanie, Parweez; Hammink, Edwin; van Laarhoven, Cees J H M; Aufenacker, Theo J; Janssen, Ignace M C; Berends, Frits J
2015-01-01
Due to the increased incidence of morbid obesity, the demand for bariatric surgery is increasing. Therefore, the methods for optimising perioperative care for the improvement of surgical outcome and to increase efficacy are necessary. The aim of this prospective matched cohort study is to objectify the effect of the fast-track surgery (FTS) programme in patients undergoing primary Laparoscopic Roux-en-Y Gastric Bypass (LRYGB) surgery compared to conventional perioperative care (CPC). This study compared the perioperative outcome data of two groups of 75 consecutive morbid obese patients who underwent a primary LRYGB according to international guidelines in the periods January 2011-April 2011 (CPC group) and April 2012-June 2012 (FTS group). The two groups were matched for age and sex. Primary endpoints were surgery and hospitalisation time, while secondary endpoints were intraoperative medication use and complication rates. Baseline patient characteristics for age, sex, weight and ASA classification were similar (p > 0.05) for CPC and FTS patients. BMI and waist circumference were significantly lower (p < 0.05) in the FTS compared to CPC. The total time from arrival at the operating room to the arrival at the recovery was reduced from 119 to 82 min (p < 0.001). Surgery time was reduced from 80 to 56 min (p < 0.001); mean hospital stay was reduced from 65 to 43 h (p < 0.001). Major complications occurred in 3 versus 4 % in the FTS and CPC, respectively. The introduction of a fast-track programme after primary LRYGB improves short-term recovery and may reduces direct hospital-related resources.
Health-related quality of life and postoperative recovery in fast-track hysterectomy.
Wodlin, Ninnie Borendal; Nilsson, Lena; Kjølhede, Preben
2011-04-01
To determine whether health-related quality of life (HRQoL) and postoperative recovery of women who undergo abdominal hysterectomy in a fast-track program under general anesthesia (GA) differ from women who receive spinal anesthesia with intrathecal morphine (SA). Secondary analysis from an open randomized controlled multicenter study. Five hospitals in south-east Sweden. One hundred and eighty women admitted for abdominal hysterectomy for benign disease were randomized; 162 completed the study, 80 with GA and 82 with SA. The HRQoL was measured preoperatively using the EuroQoL EQ-5D and the Short-Form-36 health survey (SF-36) questionnaires. The EQ-5D was used daily for 1 week; thereafter, once weekly for 4 weeks and again 6 months after operation. The SF-36 was completed at 5 weeks and 6 months. Dates of commencing and ending sick leave were registered. Changes in HRQoL; duration of sick leave. The HRQoL improved significantly faster in women after SA than after GA. Sick leave was significantly shorter after SA than after GA (median 22.5 vs. 28 days). Recovery of HRQoL and duration of sick leave were negatively influenced by postoperative complications. In particular, the mental component of HRQoL was negatively affected by minor complications, even 6 months after the operation. Spinal anesthesia with intrathecal morphine provided substantial advantages in fast-track abdominal hysterectomy for benign gynecological disorders by providing faster recovery and shorter sick leave compared with general anesthesia. © 2011 The Authors Acta Obstetricia et Gynecologica Scandinavica© 2011 Nordic Federation of Societies of Obstetrics and Gynecology.
Ottesen, Marianne; Sørensen, Mette; Rasmussen, Yvonne; Smidt-Jensen, Steen; Kehlet, Henrik; Ottesen, Bent
2002-02-01
Our aim was to describe the need for postoperative hospitalization after vaginal surgery for utero-vaginal prolapse with well-defined charts for postoperative care. A prospective, descriptive study. Consecutive women admitted for first-time vaginal surgery for utero-vaginal prolapse at a public university hospital in Copenhagen, Denmark, underwent surgery and postoperative care in a fast track setting from September 15, 1999 to June 15 2000. A multimodal rehabilitation model with emphasis on information, standardized general anesthesia, reduced surgical distress, optimized pain-relief, early oral nutrition and ambulation, minimal use of indwelling catheter and vaginal packing. Postoperative hospital stay, complications, re-admission, success rate, patients' satisfaction and acceptability. Forty-one women with a median age of 69 years (range, 44-88 years) were included. All underwent anterior and/or posterior vaginal repair. Nineteen (46.3%) underwent vaginal hysterectomy, and eight (19.5%) underwent the Manchester procedure. Postoperative hospital stay was median 24 hr. Only three (7.3%) were discharged later than 48 hr. No re-admissions occurred. The most frequent complications were urinary retention exceeding 450 ml, and urinary tract infection (12.2%, and 9.8%, respectively). Short-term success rate was 97.6%. Patients' satisfaction rates were 85.4-95.1%. The median score of acceptability was 10 on a 0-10 points scale. The need for postoperative hospitalization was median 24 hr after vaginal surgery in a fast track setting, independently of the complexity of the procedure performed. Short-term success rate, satisfaction rates, and acceptability were all excellent. Follow up has been established to evaluate long-term success rates and recurrence.
Fast-track surgery concepts for congenital urogenital anomalies.
Bizic, Marta R; Majstorovic, Marko J; Vukadinovic, Vojkan; Korac, Gradimir; Krstic, Zoran; Radojicic, Zoran; Ducic, Sinisa; Djordjevic, Miroslav L
2013-01-01
To investigate the possibility of fast-track surgery concepts in pediatric urology department as a single center study model of a developing country. The study included 1620 patients surgically treated at the pediatric urology department, from 2009 to 2011. According to the congenital anomalies, all patients were classified in one of four groups: I - testicular anomalies (197 patients); II - external genital anomalies (453); III - upper urinary tract anomalies (801) and IV - associated anomalies (169). We analyzed the total duration of stay in the hospital of all patients among all treating doctors concerning the anomaly. Statistically significant difference in total length of hospitalization of all patients in Group I was noted in Doctors 1 and 5 (F=10.36** for F0.05;5;12=3.11 and F0.01;5;12=5.06), as well as in the Group II (F=17.01** for F0.05;5;12=3.11 and F0.01;5;12=5.06). Statistical analysis was not possible to be performed in groups III and IV because of lack of the patients. Analyzing the length of hospitalization of the patients treated at the urology department, all doctors showed the tendency to shorten the total length of hospitalization in patients of all groups. Majority of the studies carried out on pediatric urology departments in developed countries, showed that over 50% of children were successfully treated using fast-track surgery concept. Modern methods of surgical management and anesthesia allow decrease of hospitalization length, financial savings to the healthcare system and better comfort for patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Kyung Hwan; Muniyappan, Srinivasan; Oang, Key Young
2012-05-29
Proteins serve as molecular machines in performing their biological functions, but the detailed structural transitions are difficult to observe in their native aqueous environments in real time. For example, despite extensive studies, the solution-phase structures of the intermediates along the allosteric pathways for the transitions between the relaxed (R) and tense (T) forms have been elusive. In this work, we employed picosecond X-ray solution scattering and novel structural analysis to track the details of the structural dynamics of wild-type homodimeric hemoglobin (HbI) from the clam Scapharca inaequivalvis and its F97Y mutant over a wide time range from 100 ps tomore » 56.2 ms. From kinetic analysis of the measured time-resolved X-ray solution scattering data, we identified three structurally distinct intermediates (I 1, I 2, and I 3) and their kinetic pathways common for both the wild type and the mutant. The data revealed that the singly liganded and unliganded forms of each intermediate share the same structure, providing direct evidence that the ligand photolysis of only a single subunit induces the same structural change as the complete photolysis of both subunits does. In addition, by applying novel structural analysis to the scattering data, we elucidated the detailed structural changes in the protein, including changes in the heme-heme distance, the quaternary rotation angle of subunits, and interfacial water gain/loss. The earliest, R-like I 1 intermediate is generated within 100 ps and transforms to the R-like I 2 intermediate with a time constant of 3.2 ± 0.2 ns. Subsequently, the late, T-like I 3 intermediate is formed via subunit rotation, a decrease in the heme-heme distance, and substantial gain of interfacial water and exhibits ligation-dependent formation kinetics with time constants of 730 ± 120 ns for the fully photolyzed form and 5.6 ± 0.8 μs for the partially photolyzed form. For the mutant, the overall kinetics are accelerated, and the formation of the T-like I 3 intermediate involves interfacial water loss (instead of water entry) and lacks the contraction of the heme-heme distance, thus underscoring the dramatic effect of the F97Y mutation. The ability to keep track of the detailed movements of the protein in aqueous solution in real time provides new insights into the protein structural dynamics.« less
Track reconstruction in the emulsion-lead target of the OPERA experiment using the ESS microscope
NASA Astrophysics Data System (ADS)
Arrabito, L.; Bozza, C.; Buontempo, S.; Consiglio, L.; Cozzi, M.; D'Ambrosio, N.; DeLellis, G.; DeSerio, M.; Di Capua, F.; Di Ferdinando, D.; Di Marco, N.; Ereditato, A.; Esposito, L. S.; Fini, R. A.; Giacomelli, G.; Giorgini, M.; Grella, G.; Ieva, M.; Janicsko Csathy, J.; Juget, F.; Kreslo, I.; Laktineh, I.; Manai, K.; Mandrioli, G.; Marotta, A.; Migliozzi, P.; Monacelli, P.; Moser, U.; Muciaccia, M. T.; Pastore, A.; Patrizii, L.; Petukhov, Y.; Pistillo, C.; Pozzato, M.; Romano, G.; Rosa, G.; Russo, A.; Savvinov, N.; Schembri, A.; Scotto Lavina, L.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Strolin, P.; Tioukov, V.; Waelchli, T.
2007-05-01
The OPERA experiment, designed to conclusively prove the existence of νμ→ντ oscillations in the atmospheric sector, makes use of a massive lead-nuclear emulsion target to observe the appearance of ντ's in the CNGS νμ beam. The location and analysis of the neutrino interactions in quasi real-time required the development of fast computer-controlled microscopes able to reconstruct particle tracks with sub-micron precision and high efficiency at a speed of ~20 cm2/h. This paper describes the performance in particle track reconstruction of the European Scanning System, a novel automatic microscope for the measurement of emulsion films developed for OPERA.
NASA Astrophysics Data System (ADS)
Zhang, Qun; Yang, Yanfu; Xiang, Qian; Zhou, Zhongqing; Yao, Yong
2018-02-01
A joint compensation scheme based on cascaded Kalman filter is proposed, which can implement polarization tracking, channel equalization, frequency offset, and phase noise compensation simultaneously. The experimental results show that the proposed algorithm can not only compensate multiple channel impairments simultaneously but also improve the polarization tracking capacity and accelerate the convergence speed. The scheme has up to eight times faster convergence speed compared with radius-directed equalizer (RDE) + Max-FFT (maximum fast Fourier transform) + BPS (blind phase search) and can track up polarization rotation 60 times and 15 times faster than that of RDE + Max-FFT + BPS and CMMA (cascaded multimodulus algorithm) + Max-FFT + BPS, respectively.
Novel technique for tracking manpower and work packages: a useful tool for the team and management
NASA Astrophysics Data System (ADS)
Gill, R.; Gracia, G.; Lupton, R. H.; O'Mullane, W.
2014-08-01
In these times of austerity it is becoming more and more important to justify the need for manpower to management. Additionally, with the fast pace of today's projects the need for tools that facilitate teams to not only plan, but also track their work, are essential. The practice of planning work packages and the associated manpower has been about for a while but little is done to really cross-check that planning against reality. In this paper these elements are brought together through a number of tools that make up the end to end process of planning, tracking and reporting of work package progress and manpower usage.
On fast X-ray rotators with long-term periodicities
NASA Technical Reports Server (NTRS)
Naranan, S.; Elsner, R. F.; Darbro, W.; Ramsey, B. D.; Leahy, D. A.; Weisskopf, M. C.; Williams, A. C.; Hardee, P. E.; Sutherland, P. G.; Grindlay, J. E.
1985-01-01
The support of previous SAS 3 spacecraft observations by new data gathered by the Monitor Proportional Counter aboard the HEAO 2 spacecraft indicates that the pulse period history of the 13.5 sec-pulsing X-ray source LMC X-4 is consistent with standard accretion and torque models only if LMC X-4 is a fast rotator for which the accretion torques nearly cancel. This result leads to a neutron star magnetic field strength estimate of about 1.2 x 10 to the 13th G. Strong evidence is noted for Her X-1's status as a fast rotator, while SMC X-1 is probably an intermediate-to-fast rotator. In the context of slaved disk models for these objects, it is noted that the precession periods expected for the companion stars are significantly longer than the observed 1-2 month time scales; slaved disk models are thereby undermined.
Penetration of fast projectiles into resistant media: From macroscopic to subatomic projectiles
NASA Astrophysics Data System (ADS)
Gaite, José
2017-09-01
The penetration of a fast projectile into a resistant medium is a complex process that is suitable for simple modeling, in which basic physical principles can be profitably employed. This study connects two different domains: the fast motion of macroscopic bodies in resistant media and the interaction of charged subatomic particles with matter at high energies, which furnish the two limit cases of the problem of penetrating projectiles of different sizes. These limit cases actually have overlapping applications; for example, in space physics and technology. The intermediate or mesoscopic domain finds application in atom cluster implantation technology. Here it is shown that the penetration of fast nano-projectiles is ruled by a slightly modified Newton's inertial quadratic force, namely, F ∼v 2 - β, where β vanishes as the inverse of projectile diameter. Factors essential to penetration depth are ratio of projectile to medium density and projectile shape.
NASA Astrophysics Data System (ADS)
Thangavelautham, J.; Asphaug, E.; Schwartz, S.
2017-02-01
Our work has identified the use of on-orbit centrifuge science laboratories as a key enabler towards low-cost, fast-track physical simulation of off-world environments for future planetary science missions.
76 FR 70225 - Advisory Council to the Internal Revenue Service; Meeting
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-10
... hereby given pursuant to section 10(a) (2) of the Federal Advisory Committee Act, 5 U.S.C. App. (1988), a..., Empower Exam Managers as an Alternative to SBSE Fast Track Settlement Program, Enhance Worker...
ERIC Educational Resources Information Center
Dolan, Thomas G.
2002-01-01
Describes Clark County, Nevada's use of prototype school designs to respond to its rapidly growing school population. The purpose of the prototypes is to simplify designs so that schools can be built quickly and minimize the time and expense that comes with variations. (EV)
Cognitive dysfunction after fast-track hip and knee replacement.
Krenk, Lene; Kehlet, Henrik; Bæk Hansen, Torben; Solgaard, Søren; Soballe, Kjeld; Rasmussen, Lars Simon
2014-05-01
Postoperative cognitive dysfunction (POCD) is reported to occur after major surgery in as many as 20% of patients, elderly patients may especially experience problems in the weeks and months after surgery. Recent studies vary greatly in methods of evaluation and diagnosis of POCD, and the pathogenic mechanisms are still unclear. We evaluated a large uniform cohort of elderly patients in a standardized approach, after major joint replacement surgery (total hip and knee replacement). Patients were in an optimized perioperative approach (fast track) with multimodal opioid-sparing analgesia, early mobilization, and short length of stay (LOS ≤3 days) and discharged to home. In a prospective multicenter study, we included 225 patients aged ≥60 years undergoing well-defined fast-track total hip or total knee replacement. Patients had neuropsychological testing preoperatively and 1 to 2 weeks and 3 months postoperatively. LOS, pain, opioid use, inflammatory response, and sleep quality were recorded. The practice effect of repeated cognitive testing was gauged using data from a healthy community-dwelling control group (n = 161). Median LOS was 2 days (interquartile range 2-3). The incidence of POCD at 1 to 2 weeks was 9.1% (95% confidence interval [CI], 5.4%-13.1%) and 8.0% (95% CI, 4.5%-12.0%) at 3 months. There was no statistically significant difference between patients with and without early POCD, regarding pain, opioid use, sleep quality, or C-reactive protein response, although the CIs were wide. Patients with early POCD had a higher Mini Mental State Examination score preoperatively (difference in medians 0.5 [95% CI, -1.0% to 0.0%]; P = 0.034). If there was an association between early POCD and late POCD, the sample size was unfortunately too small to verify this (23.6% of patients with early POCD had late onset vs 6.7% in non-POCD group; risk difference 16.9 (95% CI, -2.1% to 41.1%; P = 0.089). The incidence of POCD early after total hip and knee replacement seems to be lower after a fast-track approach than rates previously reported for these procedures, but late POCD occurred with an incidence similar to that in previous studies of major noncardiac elective surgery. No association between early and late POCD could be verified.
Isom, S Clay; Li, Rong Feng; Whitworth, Kristin M; Prather, Randall S
2012-03-01
Evidence in many species has suggested that those embryos that cleave earliest after fertilization are more developmentally competent than those that cleave relatively later after fertilization. Herein we document this phenomenon in porcine in vitro-fertilized (IVF), somatic cell nuclear transfer (SCNT), and parthenogenetic (PA) embryos. In vitro-matured pig oocytes were used to generate IVF, SCNT, and PA embryos. At 24 hr post-activation (or insemination; hpa/hpi), embryos were visually assessed, and cleaved embryos were moved into a new culture well. This process was repeated at 30 and 48 hpa/hpi. All embryos were allowed to develop 7 days in culture. For IVF embryos, 39.9%, 24.6%, and 10.5% of fast-, intermediate-, or slow-cleaving embryos, respectively, developed into blastocysts by day 7. For SCNT embryos, 31.8% of fast-, 5.7% of intermediate-, and 2.9% of late-cleaving embryos achieved the blastocyst stage of development. For PA embryos, the percentages of those cleaved embryos that developed to blastocyst were 59.3%, 36.7%, and 7.5% for early-, intermediate-, and late-cleaving embryos, respectively. Using RNA collected from early-, intermediate-, and late-cleaving embryos, real-time PCR was performed to assess the transcript levels of 14 different genes of widely varied function. The qPCR results suggest that maternal mRNA degradation may not proceed in an appropriate pattern in slow-cleaving embryos. These findings (1) confirm that, as observed in other species, earlier-cleaving porcine embryos are more successful at developing in culture than are slower-cleaving embryos, and (2) implicate mechanisms of maternal transcript destruction as potential determinants of oocyte/embryo quality. Copyright © 2011 Wiley Periodicals, Inc.
Terminal Sliding Mode Tracking Controller Design for Automatic Guided Vehicle
NASA Astrophysics Data System (ADS)
Chen, Hongbin
2018-03-01
Based on sliding mode variable structure control theory, the path tracking problem of automatic guided vehicle is studied, proposed a controller design method based on the terminal sliding mode. First of all, through analyzing the characteristics of the automatic guided vehicle movement, the kinematics model is presented. Then to improve the traditional expression of terminal sliding mode, design a nonlinear sliding mode which the convergence speed is faster than the former, verified by theoretical analysis, the design of sliding mode is steady and fast convergence in the limited time. Finally combining Lyapunov method to design the tracking control law of automatic guided vehicle, the controller can make the automatic guided vehicle track the desired trajectory in the global sense as well as in finite time. The simulation results verify the correctness and effectiveness of the control law.
A Real-Time Localization System for an Endoscopic Capsule Using Magnetic Sensors †
Pham, Duc Minh; Aziz, Syed Mahfuzul
2014-01-01
Magnetic sensing technology offers an attractive alternative for in vivo tracking with much better performance than RF and ultrasound technologies. In this paper, an efficient in vivo magnetic tracking system is presented. The proposed system is intended to localize an endoscopic capsule which delivers biomarkers around specific locations of the gastrointestinal (GI) tract. For efficiently localizing a magnetic marker inside the capsule, a mathematical model has been developed for the magnetic field around a cylindrical magnet and used with a localization algorithm that provides minimum error and fast computation. The proposed tracking system has much reduced complexity compared to the ones reported in the literature to date. Laboratory tests and in vivo animal trials have demonstrated the suitability of the proposed system for tracking a magnetic marker with expected accuracy. PMID:25379813
Note: Fast neutron efficiency in CR-39 nuclear track detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cavallaro, S.
2015-03-15
CR-39 samples are commonly employed for fast neutron detection in fusion reactors and in inertial confinement fusion experiments. The literature reported efficiencies are strongly depending on experimental conditions and, in some cases, highly dispersed. The present note analyses the dependence of efficiency as a function of various parameters and experimental conditions in both the radiator-assisted and the stand-alone CR-39 configurations. Comparisons of literature experimental data with Monte Carlo calculations and optimized efficiency values are shown and discussed.
Large Area Field of View for Fast Temporal Resolution Astronomy
NASA Astrophysics Data System (ADS)
Covarrubias, Ricardo A.
2018-01-01
Scientific CMOS (sCMOS) technology is especially relevant for high temporal resolution astronomy combining high resolution, large field of view with very fast frame rates, without sacrificing ultra-low noise performance. Solar Astronomy, Near Earth Object detections, Space Debris Tracking, Transient Observations or Wavefront Sensing are among the many applications this technology can be utilized. Andor Technology is currently developing the next-generation, very large area sCMOS camera with an extremely low noise, rapid frame rates, high resolution and wide dynamic range.
Super-resolution imaging applied to moving object tracking
NASA Astrophysics Data System (ADS)
Swalaganata, Galandaru; Ratna Sulistyaningrum, Dwi; Setiyono, Budi
2017-10-01
Moving object tracking in a video is a method used to detect and analyze changes that occur in an object that being observed. Visual quality and the precision of the tracked target are highly wished in modern tracking system. The fact that the tracked object does not always seem clear causes the tracking result less precise. The reasons are low quality video, system noise, small object, and other factors. In order to improve the precision of the tracked object especially for small object, we propose a two step solution that integrates a super-resolution technique into tracking approach. First step is super-resolution imaging applied into frame sequences. This step was done by cropping the frame in several frame or all of frame. Second step is tracking the result of super-resolution images. Super-resolution image is a technique to obtain high-resolution images from low-resolution images. In this research single frame super-resolution technique is proposed for tracking approach. Single frame super-resolution was a kind of super-resolution that it has the advantage of fast computation time. The method used for tracking is Camshift. The advantages of Camshift was simple calculation based on HSV color that use its histogram for some condition and color of the object varies. The computational complexity and large memory requirements required for the implementation of super-resolution and tracking were reduced and the precision of the tracked target was good. Experiment showed that integrate a super-resolution imaging into tracking technique can track the object precisely with various background, shape changes of the object, and in a good light conditions.
Robust visual object tracking with interleaved segmentation
NASA Astrophysics Data System (ADS)
Abel, Peter; Kieritz, Hilke; Becker, Stefan; Arens, Michael
2017-10-01
In this paper we present a new approach for tracking non-rigid, deformable objects by means of merging an on-line boosting-based tracker and a fast foreground background segmentation. We extend an on-line boosting- based tracker, which uses axes-aligned bounding boxes with fixed aspect-ratio as tracking states. By constructing a confidence map from the on-line boosting-based tracker and unifying this map with a confidence map, which is obtained from a foreground background segmentation algorithm, we build a superior confidence map. For constructing a rough confidence map of a new frame based on on-line boosting, we employ the responses of the strong classifier as well as the single weak classifier responses that were built before during the updating step. This confidence map provides a rough estimation of the object's position and dimension. In order to refine this confidence map, we build a fine, pixel-wisely segmented confidence map and merge both maps together. Our segmentation method is color-histogram-based and provides a fine and fast image segmentation. By means of back-projection and the Bayes' rule, we obtain a confidence value for every pixel. The rough and the fine confidence maps are merged together by building an adaptively weighted sum of both maps. The weights are obtained by utilizing the variances of both confidence maps. Further, we apply morphological operators in the merged confidence map in order to reduce the noise. In the resulting map we estimate the object localization and dimension via continuous adaptive mean shift. Our approach provides a rotated rectangle as tracking states, which enables a more precise description of non-rigid, deformable objects than axes-aligned bounding boxes. We evaluate our tracker on the visual object tracking (VOT) benchmark dataset 2016.
Rakhimberdiev, Eldar; Winkler, David W; Bridge, Eli; Seavy, Nathaniel E; Sheldon, Daniel; Piersma, Theunis; Saveliev, Anatoly
2015-01-01
Solar archival tags (henceforth called geolocators) are tracking devices deployed on animals to reconstruct their long-distance movements on the basis of locations inferred post hoc with reference to the geographical and seasonal variations in the timing and speeds of sunrise and sunset. The increased use of geolocators has created a need for analytical tools to produce accurate and objective estimates of migration routes that are explicit in their uncertainty about the position estimates. We developed a hidden Markov chain model for the analysis of geolocator data. This model estimates tracks for animals with complex migratory behaviour by combining: (1) a shading-insensitive, template-fit physical model, (2) an uncorrelated random walk movement model that includes migratory and sedentary behavioural states, and (3) spatially explicit behavioural masks. The model is implemented in a specially developed open source R package FLightR. We used the particle filter (PF) algorithm to provide relatively fast model posterior computation. We illustrate our modelling approach with analysis of simulated data for stationary tags and of real tracks of both a tree swallow Tachycineta bicolor migrating along the east and a golden-crowned sparrow Zonotrichia atricapilla migrating along the west coast of North America. We provide a model that increases accuracy in analyses of noisy data and movements of animals with complicated migration behaviour. It provides posterior distributions for the positions of animals, their behavioural states (e.g., migrating or sedentary), and distance and direction of movement. Our approach allows biologists to estimate locations of animals with complex migratory behaviour based on raw light data. This model advances the current methods for estimating migration tracks from solar geolocation, and will benefit a fast-growing number of tracking studies with this technology.
Fast-Acquisition/Weak-Signal-Tracking GPS Receiver for HEO
NASA Technical Reports Server (NTRS)
Wintemitz, Luke; Boegner, Greg; Sirotzky, Steve
2004-01-01
A report discusses the technical background and design of the Navigator Global Positioning System (GPS) receiver -- . a radiation-hardened receiver intended for use aboard spacecraft. Navigator is capable of weak signal acquisition and tracking as well as much faster acquisition of strong or weak signals with no a priori knowledge or external aiding. Weak-signal acquisition and tracking enables GPS use in high Earth orbits (HEO), and fast acquisition allows for the receiver to remain without power until needed in any orbit. Signal acquisition and signal tracking are, respectively, the processes of finding and demodulating a signal. Acquisition is the more computationally difficult process. Previous GPS receivers employ the method of sequentially searching the two-dimensional signal parameter space (code phase and Doppler). Navigator exploits properties of the Fourier transform in a massively parallel search for the GPS signal. This method results in far faster acquisition times [in the lab, 12 GPS satellites have been acquired with no a priori knowledge in a Low-Earth-Orbit (LEO) scenario in less than one second]. Modeling has shown that Navigator will be capable of acquiring signals down to 25 dB-Hz, appropriate for HEO missions. Navigator is built using the radiation-hardened ColdFire microprocessor and housing the most computationally intense functions in dedicated field-programmable gate arrays. The high performance of the algorithm and of the receiver as a whole are made possible by optimizing computational efficiency and carefully weighing tradeoffs among the sampling rate, data format, and data-path bit width.
Mittal, Nikita; Özer, Merve S; Schmittel, Michael
2018-04-02
A three-component supramolecular walker system is presented where a two-footed ligand (biped) walks back and forth on a tetrahedral 3D track upon the addition and removal of copper(I) ions, respectively. The addition of N-methylpyrrolidine as a catalyst to the walker system generates a four-component catalytic machinery, which acts as a three-state switchable catalytic ensemble in the presence of substrates for a conjugate addition. The copper(I)-ion-initiated walking process of the biped ligand on the track regulates the catalytic activity in three steps: ON versus int ON (intermediate ON) versus OFF. To establish the operation of the four-component catalytic machinery in a mixture of all constituents, forward and backward cycles were performed in situ illustrating that both the walking process and catalytic action are fully reversible and reproducible.
Fossil track and thermoluminescence studies of Luna 20 material.
NASA Technical Reports Server (NTRS)
Crozaz, G.; Walker, R.; Zimmerman, D.
1973-01-01
Track densities in 85 feldspar crystals from L-2009 range from 2,500,000 per sq cm to greater than one billion per sq cm. This track distribution represents an intermediate case between what have been previously defined as lightly and heavily irradiated soils and suggests that the Luna 20 sample consists of a mixture of a mature, heavily irradiated component with another, lightly irradiated component. Using a two-component mixing model, the age of the lightly irradiated component is about 270,000,000 yr. It is possible, but by no means certain, that this is associated with the formation of the crater Apollonius C. At about 200 C the ratio of natural thermoluminescence to that induced by a standard irradiation is similar to that in Apollo 12 and 14 cores below about 7 cm. This confirms that most of the Luna 20 sample represents subsurface material.
CEFR and Eye Movement Characteristics during EFL Reading: The Case of Intermediate Readers
ERIC Educational Resources Information Center
Dolgunsöz, Emrah; Sariçoban, Arif
2016-01-01
This study primarily aims to (1) examine the relationship between foreign language reading proficiency and eye movements during reading, and (2) to describe eye movement differences between two CEFR proficiency groups (B1 and B2) by using eye tracking technique. 57 learners of EFL were tested under two experimental conditions: Natural L2 reading…
The astrophysical science case for a decihertz gravitational-wave detector
NASA Astrophysics Data System (ADS)
Mandel, Ilya; Sesana, Alberto; Vecchio, Alberto
2018-03-01
We discuss the astrophysical science case for a decihertz gravitational-wave mission. We focus on unique opportunities for scientific discovery in this frequency range, including probes of type IA supernova progenitors, mergers in the presence of third bodies, intermediate mass black holes, seeds of massive black holes, improved sky localization, and tracking the population of merging compact binaries.
Affinity-based strategies to fast track development of colon cancer biomarkers — EDRN Public Portal
Our goal is to discover plasma and tissue-based tumor biomarkers that work well enough together to identity colon cancer at early stages, lead to accurate diagnosis and could ultimately allow for individualized treatment.
78 FR 64202 - Quantitative Messaging Research
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-28
... COMMODITY FUTURES TRADING COMMISSION Quantitative Messaging Research AGENCY: Commodity Futures... survey will follow qualitative message testing research (for which CFTC received fast- track OMB approval... comments. Please submit your comments using only one method and identify that it is for the ``Quantitative...
Kalachanis, Dimitrios; Manetas, Yiannis
2010-07-01
Limited evidence up to now indicates low linear photosynthetic electron flow and CO(2) assimilation rates in non-foliar chloroplasts. In this investigation, we used chlorophyll fluorescence techniques to locate possible limiting steps in photosystem function in exposed, non-stressed green fruits (both pericarps and seeds) of three species, while corresponding leaves served as controls. Compared with leaves, fruit photosynthesis was characterized by less photon trapping and less quantum yields of electron flow, while the non-photochemical quenching was higher and potentially linked to enhanced carotenoid/chlorophyll ratios. Analysis of fast chlorophyll fluorescence rise curves revealed possible limitations both in the donor (oxygen evolving complex) and the acceptor (Q(A)(-)--> intermediate carriers) sides of photosystem II (PSII) indicating innately low PSII photochemical activity. On the other hand, PSI was characterized by faster reduction of its final electron acceptors and their small pool sizes. We argue that the fast reductive saturation of final PSI electron acceptors may divert electrons back to intermediate carriers facilitating a cyclic flow around PSI, while the partial inactivation of linear flow precludes strong reduction of plastoquinone. As such, the photosynthetic attributes of fruit chloroplasts may act to replenish the ATP lost because of hypoxia usually encountered in sink organs with high diffusive resistance to gas exchange.
Active disturbance rejection controller of fine tracking system for free space optical communication
NASA Astrophysics Data System (ADS)
Cui, Ning; Liu, Yang; Chen, Xinglin; Wang, Yan
2013-08-01
Free space optical communication is one of the best approaches in future communications. Laser beam's acquisition, pointing and tracking are crucial technologies of free space optical communication. Fine tracking system is important component of APT (acquisition, pointing and tracking) system. It cooperates with the coarse pointing system in executing the APT mission. Satellite platform vibration and disturbance, which reduce received optical power, increase bit error rate and affect seriously the natural performance of laser communication. For the characteristic of satellite platform, an active disturbance rejection controller was designed to reduce the vibration and disturbance. There are three major contributions in the paper. Firstly, the effects of vibration on the inter satellite optical communications were analyzed, and the reasons and characters of vibration of the satellite platform were summarized. The amplitude-frequency response of a filter was designed according to the power spectral density of platform vibration of SILEX (Semiconductor Inter-satellite Laser Experiment), and then the signals of platform vibration were generated by filtering white Gaussian noise using the filter. Secondly, the fast steering mirror is a key component of the fine tracking system for optical communication. The mechanical design and model analysis was made to the tip/tilt mirror driven by the piezoelectric actuator and transmitted by the flexure hinge. The transfer function of the fast steering mirror, camera, D/A data acquisition card was established, and the theory model of transfer function of this system was further obtained. Finally, an active disturbance rejection control method is developed, multiple parallel extended state observers were designed for estimation of unknown dynamics and external disturbance, and the estimated states were used for nonlinear feedback control and compensation to improve system performance. The simulation results show that the designed controller not only accurately estimates and compensates the disturbances, but also realizes the robustness to estimation of unknown dynamics. The controller can satisfy the requirement of fine tracking accuracy for free space optical communication system.
Convolutional networks for vehicle track segmentation
Quach, Tu-Thach
2017-08-19
Existing methods to detect vehicle tracks in coherent change detection images, a product of combining two synthetic aperture radar images taken at different times of the same scene, rely on simple, fast models to label track pixels. These models, however, are unable to capture natural track features such as continuity and parallelism. More powerful, but computationally expensive models can be used in offline settings. We present an approach that uses dilated convolutional networks consisting of a series of 3-by-3 convolutions to segment vehicle tracks. The design of our networks considers the fact that remote sensing applications tend to operate inmore » low power and have limited training data. As a result, we aim for small, efficient networks that can be trained end-to-end to learn natural track features entirely from limited training data. We demonstrate that our 6-layer network, trained on just 90 images, is computationally efficient and improves the F-score on a standard dataset to 0.992, up from 0.959 obtained by the current state-of-the-art method.« less
Convolutional networks for vehicle track segmentation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quach, Tu-Thach
Existing methods to detect vehicle tracks in coherent change detection images, a product of combining two synthetic aperture radar images taken at different times of the same scene, rely on simple, fast models to label track pixels. These models, however, are unable to capture natural track features such as continuity and parallelism. More powerful, but computationally expensive models can be used in offline settings. We present an approach that uses dilated convolutional networks consisting of a series of 3-by-3 convolutions to segment vehicle tracks. The design of our networks considers the fact that remote sensing applications tend to operate inmore » low power and have limited training data. As a result, we aim for small, efficient networks that can be trained end-to-end to learn natural track features entirely from limited training data. We demonstrate that our 6-layer network, trained on just 90 images, is computationally efficient and improves the F-score on a standard dataset to 0.992, up from 0.959 obtained by the current state-of-the-art method.« less
NASA Astrophysics Data System (ADS)
Yue, Fengfa; Li, Xingfei; Chen, Cheng; Tan, Wenbin
2017-12-01
In order to improve the control accuracy and stability of opto-electronic tracking system fixed on reef or airport under friction and external disturbance conditions, adaptive integral backstepping sliding mode control approach with friction compensation is developed to achieve accurate and stable tracking for fast moving target. The nonlinear observer and slide mode controller based on modified LuGre model with friction compensation can effectively reduce the influence of nonlinear friction and disturbance of this servo system. The stability of the closed-loop system is guaranteed by Lyapunov theory. The steady-state error of the system is eliminated by integral action. The adaptive integral backstepping sliding mode controller and its performance are validated by a nonlinear modified LuGre dynamic model of the opto-electronic tracking system in simulation and practical experiments. The experiment results demonstrate that the proposed controller can effectively realise the accuracy and stability control of opto-electronic tracking system.
Automatic Tracking Algorithm in Coaxial Near-Infrared Laser Ablation Endoscope for Fetus Surgery
NASA Astrophysics Data System (ADS)
Hu, Yan; Yamanaka, Noriaki; Masamune, Ken
2014-07-01
This article reports a stable vessel object tracking method for the treatment of twin-to-twin transfusion syndrome based on our previous 2 DOF endoscope. During the treatment of laser coagulation, it is necessary to focus on the exact position of the target object, however it moves by the mother's respiratory motion and still remains a challenge to obtain and track the position precisely. In this article, an algorithm which uses features from accelerated segment test (FAST) to extract the features and optical flow as the object tracking method, is proposed to deal with above problem. Further, we experimentally simulate the movement due to the mother's respiration, and the results of position errors and similarity verify the effectiveness of the proposed tracking algorithm for laser ablation endoscopy in-vitro and under water considering two influential factors. At average, the errors are about 10 pixels and the similarity over 0.92 are obtained in the experiments.
Kernelized correlation tracking with long-term motion cues
NASA Astrophysics Data System (ADS)
Lv, Yunqiu; Liu, Kai; Cheng, Fei
2018-04-01
Robust object tracking is a challenging task in computer vision due to interruptions such as deformation, fast motion and especially, occlusion of tracked object. When occlusions occur, image data will be unreliable and is insufficient for the tracker to depict the object of interest. Therefore, most trackers are prone to fail under occlusion. In this paper, an occlusion judgement and handling method based on segmentation of the target is proposed. If the target is occluded, the speed and direction of it must be different from the objects occluding it. Hence, the value of motion features are emphasized. Considering the efficiency and robustness of Kernelized Correlation Filter Tracking (KCF), it is adopted as a pre-tracker to obtain a predicted position of the target. By analyzing long-term motion cues of objects around this position, the tracked object is labelled. Hence, occlusion could be detected easily. Experimental results suggest that our tracker achieves a favorable performance and effectively handles occlusion and drifting problems.
First satellite tracks of neonate sea turtles redefine the ‘lost years’ oceanic niche
Mansfield, Katherine L.; Wyneken, Jeanette; Porter, Warren P.; Luo, Jiangang
2014-01-01
Few at-sea behavioural data exist for oceanic-stage neonate sea turtles, a life-stage commonly referred to as the sea turtle ‘lost years’. Historically, the long-term tracking of small, fast-growing organisms in the open ocean was logistically or technologically impossible. Here, we provide the first long-term satellite tracks of neonate sea turtles. Loggerheads (Caretta caretta) were remotely tracked in the Atlantic Ocean using small solar-powered satellite transmitters. We show that oceanic-stage turtles (i) rarely travel in Continental Shelf waters, (ii) frequently depart the currents associated with the North Atlantic Subtropical Gyre, (iii) travel quickly when in Gyre currents, and (iv) select sea surface habitats that are likely to provide a thermal benefit or refuge to young sea turtles, supporting growth, foraging and survival. Our satellite tracks help define Atlantic loggerhead nursery grounds and early loggerhead habitat use, allowing us to re-examine sea turtle ‘lost years’ paradigms. PMID:24598420
Gunkel, Monika; Schöneberg, Johannes; Alkhaldi, Weaam; Irsen, Stephan; Noé, Frank; Kaupp, U Benjamin; Al-Amoudi, Ashraf
2015-04-07
The visual pigment rhodopsin belongs to the family of G protein-coupled receptors that can form higher oligomers. It is controversial whether rhodopsin forms oligomers and whether oligomers are functionally relevant. Here, we study rhodopsin organization in cryosections of dark-adapted mouse rod photoreceptors by cryoelectron tomography. We identify four hierarchical levels of organization. Rhodopsin forms dimers; at least ten dimers form a row. Rows form pairs (tracks) that are aligned parallel to the disk incisures. Particle-based simulation shows that the combination of tracks with fast precomplex formation, i.e. rapid association and dissociation between inactive rhodopsin and the G protein transducin, leads to kinetic trapping: rhodopsin first activates transducin from its own track, whereas recruitment of transducin from other tracks proceeds more slowly. The trap mechanism could produce uniform single-photon responses independent of rhodopsin lifetime. In general, tracks might provide a platform that coordinates the spatiotemporal interaction of signaling molecules. Copyright © 2015 Elsevier Ltd. All rights reserved.
A Railway Track Geometry Measuring Trolley System Based on Aided INS
Chen, Qijin; Niu, Xiaoji; Zuo, Lili; Zhang, Tisheng; Xiao, Fuqin; Liu, Yi; Liu, Jingnan
2018-01-01
Accurate measurement of the railway track geometry is a task of fundamental importance to ensure the track quality in both the construction phase and the regular maintenance stage. Conventional track geometry measuring trolleys (TGMTs) in combination with classical geodetic surveying apparatus such as total stations alone cannot meet the requirements of measurement accuracy and surveying efficiency at the same time. Accurate and fast track geometry surveying applications call for an innovative surveying method that can measure all or most of the track geometric parameters in short time without interrupting the railway traffic. We provide a novel solution to this problem by integrating an inertial navigation system (INS) with a geodetic surveying apparatus, and design a modular TGMT system based on aided INS, which can be configured according to different surveying tasks including precise adjustment of slab track, providing tamping measurements, measuring track deformation and irregularities, and determination of the track axis. TGMT based on aided INS can operate in mobile surveying mode to significantly improve the surveying efficiency. Key points in the design of the TGMT’s architecture and the data processing concept and workflow are introduced in details, which should benefit subsequent research and provide a reference for the implementation of this kind of TGMT. The surveying performance of proposed TGMT with different configurations is assessed in the track geometry surveying experiments and actual projects. PMID:29439423
The Fleet Application for Scheduling and Tracking (FAST) Management Website
NASA Technical Reports Server (NTRS)
Marrero-Perez, Radames J.
2014-01-01
The FAST application was designed to replace the paper and pen method of checking out and checking in GSA Vehicles at KSC. By innovating from a paper and pen based checkout system to a fully digital one, not only the resources wasted by printing the checkout forms have been reduced, but it also reduces significantly the time that users and fleet managers need to interact with the system as well as improving the record accuracy for each vehicle. The vehicle information is pulled from a centralized database server in the SPSDL. In an attempt to add a new feature to the FAST application, the author of this report (alongside the FAST developers) has been designing and developing the FAST Management Website. The GSA fleet managers had to rely on the FAST developers in order to add new vehicles, edit vehicles and previous transactions, or for generating vehicles reports. By providing an easy-to-use FAST Management Website portal, the GSA fleet managers are now able to easily move vehicles, edit records, and print reports.
NASA Astrophysics Data System (ADS)
Block, Johanna; Witt, Hannes; Candelli, Andrea; Peterman, Erwin J. G.; Wuite, Gijs J. L.; Janshoff, Andreas; Köster, Sarah
2017-01-01
The mechanical properties of eukaryotic cells are to a great extent determined by the cytoskeleton, a composite network of different filamentous proteins. Among these, intermediate filaments (IFs) are exceptional in their molecular architecture and mechanical properties. Here we directly record stress-strain curves of individual vimentin IFs using optical traps and atomic force microscopy. We find a strong loading rate dependence of the mechanical response, supporting the hypothesis that IFs could serve to protect eukaryotic cells from fast, large deformations. Our experimental results show different unfolding regimes, which we can quantitatively reproduce by an elastically coupled system of multiple two-state elements.
Fier, Patrick S.; Luo, Jingwei; Hartwig, John F.
2013-01-01
A method for the direct conversion of arylboronate esters to aryl fluorides under mild conditions with readily available reagents is reported. Tandem reactions have also been developed for the fluorination of arenes and aryl bromides through aryl-boronate ester intermediates. Mechanistic studies suggest that this fluorination reaction occurs through facile oxidation of Cu(I) to Cu(III) followed by rate-limiting transmetallation of a bound arylboronate to Cu(III). Fast C-F reductive elimination is proposed to occur from an aryl-copper(III)-fluoride complex. Cu(III) intermediates have been generated independently and identified by NMR spectroscopy and ESI-MS. PMID:23384209
ACTS: from ATLAS software towards a common track reconstruction software
NASA Astrophysics Data System (ADS)
Gumpert, C.; Salzburger, A.; Kiehn, M.; Hrdinka, J.; Calace, N.; ATLAS Collaboration
2017-10-01
Reconstruction of charged particles’ trajectories is a crucial task for most particle physics experiments. The high instantaneous luminosity achieved at the LHC leads to a high number of proton-proton collisions per bunch crossing, which has put the track reconstruction software of the LHC experiments through a thorough test. Preserving track reconstruction performance under increasingly difficult experimental conditions, while keeping the usage of computational resources at a reasonable level, is an inherent problem for many HEP experiments. Exploiting concurrent algorithms and using multivariate techniques for track identification are the primary strategies to achieve that goal. Starting from current ATLAS software, the ACTS project aims to encapsulate track reconstruction software into a generic, framework- and experiment-independent software package. It provides a set of high-level algorithms and data structures for performing track reconstruction tasks as well as fast track simulation. The software is developed with special emphasis on thread-safety to support parallel execution of the code and data structures are optimised for vectorisation to speed up linear algebra operations. The implementation is agnostic to the details of the detection technologies and magnetic field configuration which makes it applicable to many different experiments.
USDA-ARS?s Scientific Manuscript database
Guayule is a perennial shrub grown in the southwestern United States that is used to produce high quality, natural rubber latex. However, only about 10% of the plant material is used for latex production; the remaining biomass, called bagasse, can be used for renewable fuel production. Fast pyroly...
Crown Release Increases Diameter Growth and Bole Sprouting of Pole-Size Yellow Birch
Gayne G. Erdmann; Ralph M. Jr. Peterson
1971-01-01
During the second and third years after release, dominant, codominant, and intermediate pole-size yellow birch grew nearly twice as fast in diameter as unreleased poles. Growth rates were also related to foliage density. Epicormic sprouting was increased by crown release but most sprouting occured in the second log.
Novel Organic Synthesis through Ultrafast Chemistry.
Wirth, Thomas
2017-01-16
How fast are flashes? The field of flow chemistry has recently received increasing attention owing to the availability of commercial flow equipment. New syntheses with very short-lived intermediates have been enabled by sub-millisecond mixing and reaction regimes in tailor-made flow devices. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
de Andrade, Jucimara Kulek; de Andrade, Camila Kulek; Komatsu, Emy; Perreault, Hélène; Torres, Yohandra Reyes; da Rosa, Marcos Roberto; Felsner, Maria Lurdes
2017-08-01
Corn syrups, important ingredients used in food and beverage industries, often contain high levels of 5-hydroxymethyl-2-furfural (HMF), a toxic contaminant. In this work, an in house validation of a difference spectrophotometric method for HMF analysis in corn syrups was developed using sophisticated statistical tools by the first time. The methodology showed excellent analytical performance with good selectivity, linearity (R 2 =99.9%, r>0.99), accuracy and low limits (LOD=0.10mgL -1 and LOQ=0.34mgL -1 ). An excellent precision was confirmed by repeatability (RSD (%)=0.30) and intermediate precision (RSD (%)=0.36) estimates and by Horrat value (0.07). A detailed study of method precision using a nested design demonstrated that variation sources such as instruments, operators and time did not interfere in the variability of results within laboratory and consequently in its intermediate precision. The developed method is environmentally friendly, fast, cheap and easy to implement resulting in an attractive alternative for corn syrups quality control in industries and official laboratories. Copyright © 2017 Elsevier Ltd. All rights reserved.
Toraman, Hilal E; Vanholme, Ruben; Borén, Eleonora; Vanwonterghem, Yumi; Djokic, Marko R; Yildiz, Guray; Ronsse, Frederik; Prins, Wolter; Boerjan, Wout; Van Geem, Kevin M; Marin, Guy B
2016-05-01
Wild-type and two genetically engineered hybrid poplar lines were pyrolyzed in a micro-pyrolysis (Py-GC/MS) and a bench scale setup for fast and intermediate pyrolysis studies. Principal component analysis showed that the pyrolysis vapors obtained by micro-pyrolysis from wood of caffeic acid O-methyltransferase (COMT) and caffeoyl-CoA O-methyltransferase (CCoAOMT) down-regulated poplar trees differed significantly from the pyrolysis vapors obtained from non-transgenic control trees. Both fast micro-pyrolysis and intermediate pyrolysis of transgenic hybrid poplars showed that down-regulation of COMT can enhance the relative yield of guaiacyl lignin-derived products, while the relative yield of syringyl lignin-derived products was up to a factor 3 lower. This study indicates that lignin engineering via genetic modifications of genes involved in the phenylpropanoid and monolignol biosynthetic pathways can help to steer the pyrolytic production of guaiacyl and syringyl lignin-derived phenolic compounds such as guaiacol, 4-methylguaiacol, 4-ethylguaiacol, 4-vinylguaiacol, syringol, 4-vinylsyringol, and syringaldehyde present in the bio-oil. Copyright © 2016 Elsevier Ltd. All rights reserved.
Torri, Isadora Dalla Vecchia; Paasikallio, Ville; Faccini, Candice Schmitt; Huff, Rafael; Caramão, Elina Bastos; Sacon, Vera; Oasmaa, Anja; Zini, Claudia Alcaraz
2016-01-01
Bio-oils were produced through intermediate (IP) and fast pyrolysis (FP), using Eucalyptus sp. (hardwood) and Picea abies (softwood), wood wastes produced in large scale in Pulp and Paper industries. Characterization of these bio-oils was made using GC/qMS and GC×GC/TOFMS. The use of GC×GC provided a broader characterization of bio-oils and it allowed tracing potential markers of hardwood bio-oil, such as dimethoxy-phenols, which might co-elute in 1D-GC. Catalytic FP increased the percentage of aromatic hydrocarbons in P. abies bio-oil, indicating its potential for fuel production. However, the presence of polyaromatic hydrocarbons (PAH) draws attention to the need of a proper management of pyrolysis process in order to avoid the production of toxic compounds and also to the importance of GC×GC/TOFMS use to avoid co-elutions and consequent inaccuracies related to identification and quantification associated with GC/qMS. Ketones and phenols were the major bio-oil compounds and they might be applied to polymer production. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Bultinck, E.; Mahieu, S.; Depla, D.; Bogaerts, A.
2010-07-01
'Bohm diffusion' causes the electrons to diffuse perpendicularly to the magnetic field lines. However, its origin is not yet completely understood: low and high frequency electric field fluctuations are both named to cause Bohm diffusion. The importance of including this process in a Monte Carlo (MC) model is demonstrated by comparing calculated ionization rates with particle-in-cell/Monte Carlo collisions (PIC/MCC) simulations. A good agreement is found with a Bohm diffusion parameter of 0.05, which corresponds well to experiments. Since the PIC/MCC method accounts for fast electric field fluctuations, we conclude that Bohm diffusion is caused by fast electric field phenomena.
Chang, Qing; Peng, Yue'e; Shi, Bin; Dan, Conghui; Yang, Yijun; Shuai, Qin
2016-05-01
Many secondary metabolites in plants are labile compounds which under environmental stress, are difficult to detect and track due to the lack of rapid in situ identification techniques, making plant metabolomics research difficult. Therefore, developing a reliable analytical method for rapid in situ identification of labile compounds and their short-lived intermediates in plants is of great importance. To develop under atmospheric pressure, a rapid in situ method for effective identification of labile compounds and their short-lived intermediates in fresh plants. An in vivo nanospray high-resolution mass spectrometry (HR-MS) method was used for rapid capture of labile compounds and their short-lived intermediates in plants. A quartz capillary was partially inserted into fresh plant tissues, and the liquid flowed out through the capillary tube owing to the capillary effect. A high direct current (d.c.) voltage was applied to the plant to generate a spray of charged droplets from the tip of the capillary carrying bioactive molecules toward the inlet of mass spectrometer for full-scan and MS/MS analysis. Many labile compounds and short-lived intermediates were identified via this method: including glucosinolates and their short-lived intermediates (existing for only 10 s) in Raphanus sativus roots, alliin and its conversion intermediate (existing for 20 s) in Allium sativum and labile precursor compound chlorogenic acid in Malus pumila Mill. The method is an effective approach for in situ identification of internal labile compounds and their short-lived intermediates in fresh plants and it can be used as an auxiliary tool to explore the degradation mechanisms of new labile plant compounds. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
MetaTracker: integration and abstraction of 3D motion tracking data from multiple hardware systems
NASA Astrophysics Data System (ADS)
Kopecky, Ken; Winer, Eliot
2014-06-01
Motion tracking has long been one of the primary challenges in mixed reality (MR), augmented reality (AR), and virtual reality (VR). Military and defense training can provide particularly difficult challenges for motion tracking, such as in the case of Military Operations in Urban Terrain (MOUT) and other dismounted, close quarters simulations. These simulations can take place across multiple rooms, with many fast-moving objects that need to be tracked with a high degree of accuracy and low latency. Many tracking technologies exist, such as optical, inertial, ultrasonic, and magnetic. Some tracking systems even combine these technologies to complement each other. However, there are no systems that provide a high-resolution, flexible, wide-area solution that is resistant to occlusion. While frameworks exist that simplify the use of tracking systems and other input devices, none allow data from multiple tracking systems to be combined, as if from a single system. In this paper, we introduce a method for compensating for the weaknesses of individual tracking systems by combining data from multiple sources and presenting it as a single tracking system. Individual tracked objects are identified by name, and their data is provided to simulation applications through a server program. This allows tracked objects to transition seamlessly from the area of one tracking system to another. Furthermore, it abstracts away the individual drivers, APIs, and data formats for each system, providing a simplified API that can be used to receive data from any of the available tracking systems. Finally, when single-piece tracking systems are used, those systems can themselves be tracked, allowing for real-time adjustment of the trackable area. This allows simulation operators to leverage limited resources in more effective ways, improving the quality of training.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benoit Forget; Mehdi Asgari; Rodolfo M. Ferrer
2007-11-01
As part of the GNEP program, it is envisioned to build a fast reactor for the transmutation of minor actinides. The spent nuclear fuel from the current fleet of light water reactors would be recycled, the current baseline is the UREX+1a process, and would act as a feed for the fast reactor. As the fuel is irradiated in a fast reactor a certain quantity of minor actinides would thus build up in the fuel stream creating possible concerns with the neutron emission of these minor actinides for fuel transportation, handling and fabrication. Past neutronic analyses had not tracked minor actinidesmore » above Cm-246 in the transmutation chain, because of the small influence on the overall reactor performance and cycle parameters. However, when trying to quantify the neutron emission from the recycled fuel with high minor actinide content, these higher isotopes play an essential role and should be included in the analysis. In this paper, the influence of tracking these minor actinides on the calculated neutron emission is presented. Also presented is the particular influence of choosing a different evaluated cross section data set to represent the minor actinides above Cm-246. The first representation uses the cross-sections provided by MC2-2 for all isotopes, while the second representation uses infinitely diluted ENDF/BVII.0 cross-sections for Cm-247 to Cf-252 and MC2-2 for all other isotopes.« less
Monocular Stereo Measurement Using High-Speed Catadioptric Tracking
Hu, Shaopeng; Matsumoto, Yuji; Takaki, Takeshi; Ishii, Idaku
2017-01-01
This paper presents a novel concept of real-time catadioptric stereo tracking using a single ultrafast mirror-drive pan-tilt active vision system that can simultaneously switch between hundreds of different views in a second. By accelerating video-shooting, computation, and actuation at the millisecond-granularity level for time-division multithreaded processing in ultrafast gaze control, the active vision system can function virtually as two or more tracking cameras with different views. It enables a single active vision system to act as virtual left and right pan-tilt cameras that can simultaneously shoot a pair of stereo images for the same object to be observed at arbitrary viewpoints by switching the direction of the mirrors of the active vision system frame by frame. We developed a monocular galvano-mirror-based stereo tracking system that can switch between 500 different views in a second, and it functions as a catadioptric active stereo with left and right pan-tilt tracking cameras that can virtually capture 8-bit color 512×512 images each operating at 250 fps to mechanically track a fast-moving object with a sufficient parallax for accurate 3D measurement. Several tracking experiments for moving objects in 3D space are described to demonstrate the performance of our monocular stereo tracking system. PMID:28792483
Khan, Zulfiqar Hasan; Gu, Irene Yu-Hua
2013-12-01
This paper proposes a novel Bayesian online learning and tracking scheme for video objects on Grassmann manifolds. Although manifold visual object tracking is promising, large and fast nonplanar (or out-of-plane) pose changes and long-term partial occlusions of deformable objects in video remain a challenge that limits the tracking performance. The proposed method tackles these problems with the main novelties on: 1) online estimation of object appearances on Grassmann manifolds; 2) optimal criterion-based occlusion handling for online updating of object appearances; 3) a nonlinear dynamic model for both the appearance basis matrix and its velocity; and 4) Bayesian formulations, separately for the tracking process and the online learning process, that are realized by employing two particle filters: one is on the manifold for generating appearance particles and another on the linear space for generating affine box particles. Tracking and online updating are performed in an alternating fashion to mitigate the tracking drift. Experiments using the proposed tracker on videos captured by a single dynamic/static camera have shown robust tracking performance, particularly for scenarios when target objects contain significant nonplanar pose changes and long-term partial occlusions. Comparisons with eight existing state-of-the-art/most relevant manifold/nonmanifold trackers with evaluations have provided further support to the proposed scheme.
FDA Accelerates Testing and Review of Experimental Brain Cancer Drug | FNLCR Staging
An investigational brain cancer drug made with disabled polio virus and manufactured at the Frederick National Lab has won breakthrough status from the Food and Drug Administration (FDA) to fast-track its further refinement and clinical testing. Br
FAST TRACK COMMUNICATION: Uniqueness of static black holes without analyticity
NASA Astrophysics Data System (ADS)
Chruściel, Piotr T.; Galloway, Gregory J.
2010-08-01
We show that the hypothesis of analyticity in the uniqueness theory of vacuum, or electrovacuum, static black holes is not needed. More generally, we show that prehorizons covering a closed set cannot occur in well-behaved domains of outer communications.
ERIC Educational Resources Information Center
Abbott, James F.
This article provides a detailed discussion of a team approach to building that involves a construction manager, an architect, and a contractor. Bidding methods are outlined; the major components in construction management -- value engineering and fast track scheduling -- and the use of performance specifications are discussed. The construction…
ERIC Educational Resources Information Center
Selingo, Jeffrey
2006-01-01
Northeastern University's continuing-education division is being rejuvenated with market research, faculty involvement, and a non-traditional approach under its new vice president Christopher E. Hopey. The college shifted its emphasis from undergraduates to graduate and certificate programs aimed at working professionals, resulting in a 20 percent…
Construction of a thin-bonded Portland cement concrete overlay using accelerated paving techniques.
DOT National Transportation Integrated Search
1992-01-01
The report describes the Virginia Department of Transportations' first modern experience with the construction of thin-bonded Portland cement concrete overlays of existing concrete pavements and with the fast track mode of rigid paving. The study was...
NASA Astrophysics Data System (ADS)
Foster, B.; Heath, G. P.; Llewellyn, T. J.; Gingrich, D. M.; Harnew, N.; Hallam-Baker, P. M.; Khatri, T.; McArthur, I. C.; Morawitz, P.; Nash, J.; Shield, P. D.; Topp-Jorgensen, S.; Wilson, F. F.; Allen, D. B.; Carter, R. C.; Jeffs, M. D.; Morrissey, M. C.; Quinton, S. P. H.; Lane, J. B.; Postranecky, M.
1993-05-01
The Central Tracking Detector of the ZEUS experiment employs a time difference technique to measure the z coordinate of each hit. The method provides fast, three-dimensional space point measurements which are used as input to all levels of the ZEUS trigger. Such a tracking trigger is essential in order to discriminate against events with vertices lying outside the nominal electron-proton interaction region. Since the beam crossing interval of the HERA collider is 96 ns, all data must be pipelined through the front-end readout electronics. Subsequent data aquisition employs a novel technique which utilizes a network of approximately 120 INMOS transputers to process the data in parallel. The z-by-timing method and its data aquisition have been employed successfully in recording and reconstructing tracks from electron-proton interactions in ZEUS.
A simple apparatus for quick qualitative analysis of CR39 nuclear track detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gautier, D. C.; Kline, J. L.; Flippo, K. A.
2008-10-15
Quantifying the ion pits in Columbia Resin 39 (CR39) nuclear track detector from Thomson parabolas is a time consuming and tedious process using conventional microscope based techniques. A simple inventive apparatus for fast screening and qualitative analysis of CR39 detectors has been developed, enabling efficient selection of data for a more detailed analysis. The system consists simply of a green He-Ne laser and a high-resolution digital single-lens reflex camera. The laser illuminates the edge of the CR39 at grazing incidence and couples into the plastic, acting as a light pipe. Subsequently, the laser illuminates all ion tracks on the surface.more » A high-resolution digital camera is used to photograph the scattered light from the ion tracks, enabling one to quickly determine charge states and energies measured by the Thomson parabola.« less
Alpha particle spectroscopy using FNTD and SIM super-resolution microscopy.
Kouwenberg, J J M; Kremers, G J; Slotman, J A; Wolterbeek, H T; Houtsmuller, A B; Denkova, A G; Bos, A J J
2018-06-01
Structured illumination microscopy (SIM) for the imaging of alpha particle tracks in fluorescent nuclear track detectors (FNTD) was evaluated and compared to confocal laser scanning microscopy (CLSM). FNTDs were irradiated with an external alpha source and imaged using both methodologies. SIM imaging resulted in improved resolution, without increase in scan time. Alpha particle energy estimation based on the track length, direction and intensity produced results in good agreement with the expected alpha particle energy distribution. A pronounced difference was seen in the spatial scattering of alpha particles in the detectors, where SIM showed an almost 50% reduction compared to CLSM. The improved resolution of SIM allows for more detailed studies of the tracks induced by ionising particles. The combination of SIM and FNTDs for alpha radiation paves the way for affordable and fast alpha spectroscopy and dosimetry. © 2018 The Authors. Journal of Microscopy published by JohnWiley & Sons Ltd on behalf of Royal Microscopical Society.
Real-time visual tracking of less textured three-dimensional objects on mobile platforms
NASA Astrophysics Data System (ADS)
Seo, Byung-Kuk; Park, Jungsik; Park, Hanhoon; Park, Jong-Il
2012-12-01
Natural feature-based approaches are still challenging for mobile applications (e.g., mobile augmented reality), because they are feasible only in limited environments such as highly textured and planar scenes/objects, and they need powerful mobile hardware for fast and reliable tracking. In many cases where conventional approaches are not effective, three-dimensional (3-D) knowledge of target scenes would be beneficial. We present a well-established framework for real-time visual tracking of less textured 3-D objects on mobile platforms. Our framework is based on model-based tracking that efficiently exploits partially known 3-D scene knowledge such as object models and a background's distinctive geometric or photometric knowledge. Moreover, we elaborate on implementation in order to make it suitable for real-time vision processing on mobile hardware. The performance of the framework is tested and evaluated on recent commercially available smartphones, and its feasibility is shown by real-time demonstrations.
Accurate mask-based spatially regularized correlation filter for visual tracking
NASA Astrophysics Data System (ADS)
Gu, Xiaodong; Xu, Xinping
2017-01-01
Recently, discriminative correlation filter (DCF)-based trackers have achieved extremely successful results in many competitions and benchmarks. These methods utilize a periodic assumption of the training samples to efficiently learn a classifier. However, this assumption will produce unwanted boundary effects, which severely degrade the tracking performance. Correlation filters with limited boundaries and spatially regularized DCFs were proposed to reduce boundary effects. However, their methods used the fixed mask or predesigned weights function, respectively, which was unsuitable for large appearance variation. We propose an accurate mask-based spatially regularized correlation filter for visual tracking. Our augmented objective can reduce the boundary effect even in large appearance variation. In our algorithm, the masking matrix is converted into the regularized function that acts on the correlation filter in frequency domain, which makes the algorithm fast convergence. Our online tracking algorithm performs favorably against state-of-the-art trackers on OTB-2015 Benchmark in terms of efficiency, accuracy, and robustness.
Zurauskas, Mantas; Bradu, Adrian; Ferguson, Daniel R; Hammer, Daniel X; Podoleanu, Adrian
2016-03-01
This paper presents a novel instrument for biosciences, useful for studies of moving embryos. A dual sequential imaging/measurement channel is assembled via a closed-loop tracking architecture. The dual channel system can operate in two regimes: (i) single-point Doppler signal monitoring or (ii) fast 3-D swept source OCT imaging. The system is demonstrated for characterizing cardiac dynamics in Drosophila melanogaster larva. Closed loop tracking enables long term in vivo monitoring of the larvae heart without anesthetic or physical restraint. Such an instrument can be used to measure subtle variations in the cardiac behavior otherwise obscured by the larvae movements. A fruit fly larva (top) was continuously tracked for continuous remote monitoring. A heartbeat trace of freely moving larva (bottom) was obtained by a low coherence interferometry based doppler sensing technique. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Technical Reports Server (NTRS)
Hunter, Stanley; deNolfo, G. A.; Barbier, L. M.; Link, J. T.; Son, S.; Floyd, S. R.; Guardala, N.; Skopec, M.; Stark, B.
2008-01-01
The Neutron Imaging Camera (NIC) is based on the Three-dimensional Track Imager (3DTI) technology developed at GSFC for gamma-ray astrophysics applications. The 3-DTI, a large volume time-projection chamber, provides accurate, approximately 0.4 mm resolution, 3-D tracking of charged particles. The incident direction of fast neutrons, En > 0.5 MeV, are reconstructed from the momenta and energies of the proton and triton fragments resulting from (sup 3)He(n,p) (sup 3)H interactions in the 3-DTI volume. The performance of the NIC from laboratory and accelerator tests is presented.
Studying Reaction Intermediates Formed at Graphenic Surfaces
NASA Astrophysics Data System (ADS)
Sarkar, Depanjan; Sen Gupta, Soujit; Narayanan, Rahul; Pradeep, Thalappil
2014-03-01
We report in-situ production and detection of intermediates at graphenic surfaces, especially during alcohol oxidation. Alcohol oxidation to acid occurs on graphene oxide-coated paper surface, driven by an electrical potential, in a paper spray mass spectrometry experiment. As paper spray ionization is a fast process and the time scale matches with the reaction time scale, we were able to detect the intermediate, acetal. This is the first observation of acetal formed in surface oxidation. The process is not limited to alcohols and the reaction has been extended to aldehydes, amines, phosphenes, sugars, etc., where reaction products were detected instantaneously. By combining surface reactions with ambient ionization and mass spectrometry, we show that new insights into chemical reactions become feasible. We suggest that several other chemical transformations may be studied this way. This work opens up a new pathway for different industrially and energetically important reactions using different metal catalysts and modified substrate.
Rapid response to climate change in a marginal sea.
Schroeder, K; Chiggiato, J; Josey, S A; Borghini, M; Aracri, S; Sparnocchia, S
2017-06-22
The Mediterranean Sea is a mid-latitude marginal sea, particularly responsive to climate change as reported by recent studies. The Sicily Channel is a choke point separating the sea in two main basins, the Eastern Mediterranean Sea and the Western Mediterranean Sea. Here, we report and analyse a long-term record (1993-2016) of the thermohaline properties of the Intermediate Water that crosses the Sicily Channel, showing increasing temperature and salinity trends much stronger than those observed at intermediate depths in the global ocean. We investigate the causes of the observed trends and in particular determine the role of a changing climate over the Eastern Mediterranean, where the Intermediate Water is formed. The long-term Sicily record reveals how fast the response to climate change can be in a marginal sea like the Mediterranean Sea compared to the global ocean, and demonstrates the essential role of long time series in the ocean.
Three-dimensional particle tracking via tunable color-encoded multiplexing.
Duocastella, Martí; Theriault, Christian; Arnold, Craig B
2016-03-01
We present a novel 3D tracking approach capable of locating single particles with nanometric precision over wide axial ranges. Our method uses a fast acousto-optic liquid lens implemented in a bright field microscope to multiplex light based on color into different and selectable focal planes. By separating the red, green, and blue channels from an image captured with a color camera, information from up to three focal planes can be retrieved. Multiplane information from the particle diffraction rings enables precisely locating and tracking individual objects up to an axial range about 5 times larger than conventional single-plane approaches. We apply our method to the 3D visualization of the well-known coffee-stain phenomenon in evaporating water droplets.
NASA Technical Reports Server (NTRS)
Dywer, T. A. W., III; Lee, G. K. F.
1984-01-01
In connection with the current interest in agile spacecraft maneuvers, it has become necessary to consider the nonlinear coupling effects of multiaxial rotation in the treatment of command generation and tracking problems. Multiaxial maneuvers will be required in military missions involving a fast acquisition of moving targets in space. In addition, such maneuvers are also needed for the efficient operation of robot manipulators. Attention is given to details regarding the direct nonlinear command generation and tracking, an approach which has been successfully applied to the design of control systems for V/STOL aircraft, linearizing transformations for spacecraft controlled with external thrusters, the case of flexible spacecraft dynamics, examples from robot dynamics, and problems of implementation and testing.
Waheed, Yasir; Waheed, Hasnain
2017-05-12
In last fifteen years remarkable success in the fight against human immunodeficiency virus (HIV) is achieved globally. The number of HIV infections has decreased and the number of people on antiretroviral therapy is increased. This all is possible by strong political commitments and heavy investments in the fight against HIV. Pakistan is among few Asian countries in which HIV cases are increasing year by year since 1990. There are 94000 cases of HIV in Pakistan and only 14000 are registered with government. The main source of HIV infection in Pakistan is the use of contaminated injection equipment among people who inject drugs (PWID). The overall prevalence of HIV among PWID in Pakistan is 27.2%. There are five cities in Pakistan in which HIV prevalence is above 40% in PWIDs. In June 2016, United Nations political declaration on acquired immune deficiency syndrome (AIDS) provided a global mandate to fast-track the AIDS response over the next five years to achieve the targets in Sustainable Development Goals. To achieve the targets in fast-track AIDS response, the global leaders showed strong commitments to invest $ 26 billion per year by 2020. Pakistan needs to speed up its HIV control program. There is a dire need to locate all HIV positive people and enroll them in the treatment program. Pakistan also needs to calculate exact number of people living with HIV, increase HIV treatment centers and increase HIV awareness. Recently, Global Fund invested handsome money in the fight against HIV. Let's hope the country will have effective HIV control strategy to achieve the HIV elimination target by 2030.
Development of Ultra-Fast Silicon Detectors for 4D tracking
NASA Astrophysics Data System (ADS)
Staiano, A.; Arcidiacono, R.; Boscardin, M.; Dalla Betta, G. F.; Cartiglia, N.; Cenna, F.; Ferrero, M.; Ficorella, F.; Mandurrino, M.; Obertino, M.; Pancheri, L.; Paternoster, G.; Sola, V.
2017-12-01
In this contribution we review the progress towards the development of a novel type of silicon detectors suited for tracking with a picosecond timing resolution, the so called Ultra-Fast Silicon Detectors. The goal is to create a new family of particle detectors merging excellent position and timing resolution with GHz counting capabilities, very low material budget, radiation resistance, fine granularity, low power, insensitivity to magnetic field, and affordability. We aim to achieve concurrent precisions of ~ 10 ps and ~ 10 μm with a 50 μm thick sensor. Ultra-Fast Silicon Detectors are based on the concept of Low-Gain Avalanche Detectors, which are silicon detectors with an internal multiplication mechanism so that they generate a signal which is factor ~10 larger than standard silicon detectors. The basic design of UFSD consists of a thin silicon sensor with moderate internal gain and pixelated electrodes coupled to full custom VLSI chip. An overview of test beam data on time resolution and the impact on this measurement of radiation doses at the level of those expected at HL-LHC is presented. First I-V and C-V measurements on a new FBK sensor production of UFSD, 50 μm thick, with B and Ga, activated at two diffusion temperatures, with and without C co-implantation (in Low and High concentrations), and with different effective doping concentrations in the Gain layer, are shown. Perspectives on current use of UFSD in HEP experiments (UFSD detectors have been installed in the CMS-TOTEM Precision Protons Spectrometer for the forward physics tracking, and are currently taking data) and proposed applications for a MIP timing layer in the HL-LHC upgrade are briefly discussed.
ω-Alkynyl lipid surrogates for polyunsaturated fatty acids: free radical and enzymatic oxidations.
Beavers, William N; Serwa, Remigiusz; Shimozu, Yuki; Tallman, Keri A; Vaught, Melissa; Dalvie, Esha D; Marnett, Lawrence J; Porter, Ned A
2014-08-13
Lipid and lipid metabolite profiling are important parameters in understanding the pathogenesis of many diseases. Alkynylated polyunsaturated fatty acids are potentially useful probes for tracking the fate of fatty acid metabolites. The nonenzymatic and enzymatic oxidations of ω-alkynyl linoleic acid and ω-alkynyl arachidonic acid were compared to that of linoleic and arachidonic acid. There was no detectable difference in the primary products of nonenzymatic oxidation, which comprised cis,trans-hydroxy fatty acids. Similar hydroxy fatty acid products were formed when ω-alkynyl linoleic acid and ω-alkynyl arachidonic acid were reacted with lipoxygenase enzymes that introduce oxygen at different positions in the carbon chains. The rates of oxidation of ω-alkynylated fatty acids were reduced compared to those of the natural fatty acids. Cyclooxygenase-1 and -2 did not oxidize alkynyl linoleic but efficiently oxidized alkynyl arachidonic acid. The products were identified as alkynyl 11-hydroxy-eicosatetraenoic acid, alkynyl 11-hydroxy-8,9-epoxy-eicosatrienoic acid, and alkynyl prostaglandins. This deviation from the metabolic profile of arachidonic acid may limit the utility of alkynyl arachidonic acid in the tracking of cyclooxygenase-based lipid oxidation. The formation of alkynyl 11-hydroxy-8,9-epoxy-eicosatrienoic acid compared to alkynyl prostaglandins suggests that the ω-alkyne group causes a conformational change in the fatty acid bound to the enzyme, which reduces the efficiency of cyclization of dioxalanyl intermediates to endoperoxide intermediates. Overall, ω-alkynyl linoleic acid and ω-alkynyl arachidonic acid appear to be metabolically competent surrogates for tracking the fate of polyunsaturated fatty acids when looking at models involving autoxidation and oxidation by lipoxygenases.
2011-01-01
Background Diabetes is thought to accelerate cardiovascular disease depending on the type of diet. This study in diabetic subjects was performed to investigate the metabolic, inflammatory and cardiovascular effects of nutritional components typically present in a Western, Mediterranean or high glycaemic diet. Methods Streptozotocin-diabetic pigs (~45 kg) were fed for 10 weeks supplemental (40% of dietary energy) saturated fat/cholesterol (SFC), unsaturated fat (UF) or starch (S) in an eucaloric dietary intervention study. Results Fasting plasma total, LDL and HDL cholesterol concentrations were 3-5 fold higher (p < 0.01) in SFC compared to UF and S pigs. Fasting plasma NEFA concentrations (mmol/L) were highest (p < 0.05) in SFC (1.09 ± 0.17), intermediate in UF (0.80 ± 0.14) and lowest in S pigs (0.58 ± 0.14) whereas plasma glucose (~13 mmol/L), triglyceride (~0.5 mmol/L) and insulin (~24 pmol/L) concentrations were comparable among SFC, UF and S pigs. The postprandial response area under the curves (AUC, 0-4 h) for glucose but not for insulin and triglyceride responses were intermediate in SFC (617 ± 144) and lowest (p < 0.05) in UF (378 ± 157) compared to S pigs (925 ± 139). Fasting hepatic glucose production, hepatic and peripheral insulin sensitivity and blood pressure were not different among pigs. C-reactive protein (CRP) concentrations (mg/L) were highest (p < 0.05) in SFC (25 ± 4), intermediate in S (21 ± 3) and lowest in UF pigs (14 ± 2). Liver weights, liver and muscle triglyceride concentrations, and the surface area of aorta fatty streaks were highest (p < 0.01) in SFC pigs. A positive correlation between postprandial plasma CRP and aorta fatty streaks was observed in SFC pigs (R2 = 0.95). Retroperitoneal fat depot weight (g) was intermediate in SFC (260 ± 72), lowest in S (135 ± 51) and highest (p < 0.05) in UF (571 ± 95) pigs. Conclusion Dietary saturated fat/cholesterol induces inflammation, atherosclerosis and ectopic fat deposition whereas an equally high dietary unsaturated fat load does not induce these abnormalities and shows beneficial effects on postprandial glycaemia in diabetic pigs. PMID:21756316
Koopmans, Sietse J; Dekker, Ruud; Ackermans, Mariette T; Sauerwein, Hans P; Serlie, Mireille J; van Beusekom, Heleen M M; van den Heuvel, Mieke; van der Giessen, Wim J
2011-07-14
Diabetes is thought to accelerate cardiovascular disease depending on the type of diet. This study in diabetic subjects was performed to investigate the metabolic, inflammatory and cardiovascular effects of nutritional components typically present in a Western, Mediterranean or high glycaemic diet. Streptozotocin-diabetic pigs (~45 kg) were fed for 10 weeks supplemental (40% of dietary energy) saturated fat/cholesterol (SFC), unsaturated fat (UF) or starch (S) in an eucaloric dietary intervention study. Fasting plasma total, LDL and HDL cholesterol concentrations were 3-5 fold higher (p < 0.01) in SFC compared to UF and S pigs. Fasting plasma NEFA concentrations (mmol/L) were highest (p < 0.05) in SFC (1.09 ± 0.17), intermediate in UF (0.80 ± 0.14) and lowest in S pigs (0.58 ± 0.14) whereas plasma glucose (~13 mmol/L), triglyceride (~0.5 mmol/L) and insulin (~24 pmol/L) concentrations were comparable among SFC, UF and S pigs. The postprandial response area under the curves (AUC, 0-4 h) for glucose but not for insulin and triglyceride responses were intermediate in SFC (617 ± 144) and lowest (p < 0.05) in UF (378 ± 157) compared to S pigs (925 ± 139). Fasting hepatic glucose production, hepatic and peripheral insulin sensitivity and blood pressure were not different among pigs. C-reactive protein (CRP) concentrations (mg/L) were highest (p < 0.05) in SFC (25 ± 4), intermediate in S (21 ± 3) and lowest in UF pigs (14 ± 2). Liver weights, liver and muscle triglyceride concentrations, and the surface area of aorta fatty streaks were highest (p < 0.01) in SFC pigs. A positive correlation between postprandial plasma CRP and aorta fatty streaks was observed in SFC pigs (R(2) = 0.95). Retroperitoneal fat depot weight (g) was intermediate in SFC (260 ± 72), lowest in S (135 ± 51) and highest (p < 0.05) in UF (571 ± 95) pigs. Dietary saturated fat/cholesterol induces inflammation, atherosclerosis and ectopic fat deposition whereas an equally high dietary unsaturated fat load does not induce these abnormalities and shows beneficial effects on postprandial glycaemia in diabetic pigs. © 2011 Koopmans et al; licensee BioMed Central Ltd.
Effect of the Pacing Strategies on the Open Water 10km World Swimming Championships Performances.
Rodriguez, Luis; Veiga, Santiago
2017-10-16
The aim of the present research was 1) to compare the pacing strategies of different level open water swimmers during the 10km race of the FINA 2015 World Swimming Championships (WCH), and 2) to relate these pacing strategies to the race performance. Final and intermediate split times as well as intermediate race positions from the 10-kilometer race participants (69 men and 51 women) were collected from the public domain and were divided into five groups (G1 to G5) depending on their finishing positions. Medalists and finalists (G1 and G2, respectively) presented an even pacing profile with similar swimming velocities to the less successful swimmers (G3 to G5) on the initial and mid stages of the race but a 1.5-3% increase in swimming velocity in the last quarter of the race. This fast end spurt was largely related to the race performance and was not observed in the G3 and G4 (even-paced profile) or in the G5 (positive pacing profile) groups. Intermediate race positions and lap rankings were negatively related to finishing position indicating a delayed positioning of the most successful swimmers at 25%, 50% and 75% of race distance. The adoption of a conservative starting strategy by open water swimmers with a negative pacing profile and delayed partial positioning seems to increase the chances of overall race success as it allows a fast end spurt that is highly related to successful finishing race positions.
ERIC Educational Resources Information Center
Itzek-Greulich, Heike; Vollmer, Christian
2017-01-01
Students' interest in science declines in secondary school. Therefore, motivating students to become competent and engaged in science topics that are relevant for their everyday lives is an important goal, so they can be better citizens and decision makers with socioscientific issues (e.g., climate change and waste disposal). The present study…
Wewalka, Marlene; Patti, Mary-Elizabeth; Barbato, Corinne; Houten, Sander M.
2014-01-01
Context: Bile acids (BAs) are newly recognized signaling molecules in glucose and energy homeostasis. Differences in BA profiles with type 2 diabetes mellitus (T2D) remain incompletely understood. Objective: The objective of the study was to assess serum BA composition in impaired glucose-tolerant, T2D, and normal glucose-tolerant persons and to monitor the effects of improving glycemia on serum BA composition in T2D patients. Design and Setting: This was a cross-sectional cohort study in a general population (cohort 1) and nonrandomized intervention (cohort 2). Patients and Interventions: Ninety-nine volunteers underwent oral glucose tolerance testing, and 12 persons with T2D and hyperglycemia underwent 8 weeks of intensification of treatment. Main Outcome Measures: Serum free BA and respective taurine and glycine conjugates were measured by HPLC tandem mass spectrometry. Results: Oral glucose tolerance testing identified 62 normal-, 25 impaired glucose-tolerant, and 12 T2D persons. Concentrations of total taurine-conjugated BA were higher in T2D and intermediate in impaired- compared with normal glucose-tolerant persons (P = .009). Univariate regression revealed a positive association between total taurine-BA and fasting glucose (R = 0.37, P < .001), postload glucose (R = 0.31, P < .002), hemoglobin A1c (R = 0.26, P < .001), fasting insulin (R = 0.21, P = .03), and homeostatic model assessment-estimated insulin resistance (R = 0.26, P = .01) and an inverse association with oral disposition index (R = −0.36, P < .001). Insulin-mediated glycemic improvement in T2D patients did not change fasting serum total BA or BA composition. Conclusion: Fasting taurine-conjugated BA concentrations are higher in T2D and intermediate in impaired compared with normal glucose-tolerant persons and are associated with fasting and postload glucose. Serum BAs are not altered in T2D in response to improved glycemia. Further study may elucidate whether this pattern of taurine-BA conjugation can be targeted to provide novel therapeutic approaches to treat T2D. PMID:24432996
D0 Superconducting Solenoid Quench Data and Slow Dump Data Acquisition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Markley, D.; /Fermilab
1998-06-09
This Dzero Engineering note describes the method for which the 2 Tesla Superconducting Solenoid Fast Dump and Slow Dump data are accumulated, tracked and stored. The 2 Tesla Solenoid has eleven data points that need to be tracked and then stored when a fast dump or a slow dump occur. The TI555(Texas Instruments) PLC(Programmable Logic Controller) which controls the DC power circuit that powers the Solenoid, also has access to all the voltage taps and other equipment in the circuit. The TI555 constantly logs these eleven points in a rotating memory buffer. When either a fast dump(dump switch opens) ormore » a slow dump (power supply turns off) occurs, the TI555 organizes the respective data and will down load the data to a file on DO-CCRS2. This data in this file is moved over ethernet and is stored in a CSV (comma separated format) file which can easily be examined by Microsoft Excel or any other spreadsheet. The 2 Tesla solenoid control system also locks in first fault information. The TI555 decodes the first fault and passes it along to the program collecting the data and storing it on DO-CCRS2. This first fault information is then part of the file.« less
Boukattaya, Mohamed; Mezghani, Neila; Damak, Tarak
2018-06-01
In this paper, robust and adaptive nonsingular fast terminal sliding-mode (NFTSM) control schemes for the trajectory tracking problem are proposed with known or unknown upper bound of the system uncertainty and external disturbances. The developed controllers take the advantage of the NFTSM theory to ensure fast convergence rate, singularity avoidance, and robustness against uncertainties and external disturbances. First, a robust NFTSM controller is proposed which guarantees that sliding surface and equilibrium point can be reached in a short finite-time from any initial state. Then, in order to cope with the unknown upper bound of the system uncertainty which may be occurring in practical applications, a new adaptive NFTSM algorithm is developed. One feature of the proposed control law is their adaptation techniques where the prior knowledge of parameters uncertainty and disturbances is not needed. However, the adaptive tuning law can estimate the upper bound of these uncertainties using only position and velocity measurements. Moreover, the proposed controller eliminates the chattering effect without losing the robustness property and the precision. Stability analysis is performed using the Lyapunov stability theory, and simulation studies are conducted to verify the effectiveness of the developed control schemes. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.
The Potential of the LFR and the ELSY Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cinotti, L; Smith, C F; Sienicki, J J
2007-03-12
This paper presents the current status of the development of the Lead-cooled Fast Reactor (LFR) in support of Generation IV (GEN IV) Nuclear Energy Systems. The approach being taken by the GIF plan is to address the research priorities of each member state in developing an integrated and coordinated research program to achieve common objectives, while avoiding duplication of effort. The integrated plan being prepared by the LFR Provisional System Steering Committee of the GIF, known as the LFR System research Plan (SRP) recognizes two principal technology tracks for pursuit of LFR technology: (1) a small, transportable system of 10-100more » MWe size that features a very long refueling interval, (2) a larger-sized system rated at about 600 MWe, intended for central station power generation and waste transmutation. This paper, in particular, describes the ongoing activities to develop the Small Secure Transportable Autonomous Reactor (SSTAR) and the European Lead-cooled SYstem (ELSY), the two research initiatives closely aligned with the overall tracks of the SRP and outlines the Proliferation-resistant Environment-friendly Accident-tolerant Continual & Economical Reactors (PEACER) conceived with particular focus on burning/transmuting of long-living TRU waste and fission fragments of concern, such as Tc and I. The current reference design for the SSTAR is a 20 MWe natural circulation pool-type reactor concept with a small shippable reactor vessel. Specific features of the lead coolant, the nitride fuel containing transuranics, the fast spectrum core, and the small size combine to promote a unique approach to achieve proliferation resistance, while also enabling fissile self-sufficiency, autonomous load following, simplicity of operation, reliability, transportability, as well as a high degree of passive safety. Conversion of the core thermal power into electricity at a high plant efficiency of 44% is accomplished utilizing a supercritical carbon dioxide Brayton cycle power converter. The ELSY reference design is a 600 MWe pool-type reactor cooled by pure lead. This concept has been under development since September 2006, and is sponsored by the Sixth Framework Programme of EURATOM. The ELSY project is being performed by a consortium consisting of twenty organizations including seventeen from Europe, two from Korea and one from the USA. ELSY aims to demonstrate the possibility of designing a competitive and safe fast critical reactor using simple engineered technical features while fully complying with the Generation IV goal of minor actinide (MA) burning capability. The use of a compact and simple primary circuit with the additional objective that all internal components be removable, are among the reactor features intended to assure competitive electric energy generation and long-term investment protection. Simplicity is expected to reduce both the capital cost and the construction time; these are also supported by the compactness of the reactor building (reduced footprint and height). The reduced footprint would be possible due to the elimination of the Intermediate Cooling System, the reduced elevation the result of the design approach of reduced-height components.« less