Monte Carlo modeling (MCML) of light propagation in skin layers for detection of fat thickness
NASA Astrophysics Data System (ADS)
Nilubol, Chonnipa; Treerattrakoon, Kiatnida; Mohammed, Waleed S.
2010-05-01
Nowadays, most activities require lesser physical actions, which could ultimately lead to accumulation of excessive body fat. The main roles of body fat are to store energy and acts as various kinds of insulators for the body. The thickness of fat layers can be measured to indicate fat-body weight ratio. Exceeding the body-mass index (BMI) could lead to many illnesses regarding obesity. Consequently, many studies have proposed various principles and techniques to measure the amount of fat within one's body. In this paper, infrared interactance in skin layers is studied for investigation of the influence of fat thickness upon photon travelling pattern in skin tissues using Monte Carlo model (MCML). Photon propagation is numerically simulated in simplified multi-layered tissues. The optical coefficients of each skin layers are accounted for different traveling paths of photons that move through random motion. The thickness of fat layer is varied, and changing in optical parameters is observed. Then the statistically obtained data are computed and analyzed for the effect of the fat layer upon reflection percentage using different wavelengths. The calculations have shown increment in the slope of change of reflection percentage versus fat thickness, when using infrared compare to visible light. This technique can be used to construct a mobile device that is capable of measuring the volume fraction of melanin and blood in the epidermis layer and dermis layer, to calculate for the necessary optical coefficients that would be necessary for measurement of fat thickness.
Harley, O J H; Pickford, M A
2013-04-01
Mismatches in the thickness of subcutaneous fat at the level of the umbilicus and suprapubic region can result in an unsightly bulge and an unfavourable result following standard abdominoplasty. This problem can be avoided by thinning the abdominoplasty flap. This study was carried out to assess the thickness of the subcutaneous fat layer at the level of the umbilicus and the supra-pubic region. Measurements of full thickness fat and the depth of Scarpa's fascia separating superficial and sub-Scarpa fat layers were taken from the CT scans in 69 women; mean age 52 years (range 30-79). The thickness of the skin and abdominal wall fat was an average of 7 mm thicker (max 22 mm; p < 0.05). The thickness of the fat layer superficial to Scarpa's fascia was an average of 19 mm at mid abdomen and 22 mm in the lower abdomen (p < 0.05). The thickness of the fat layer deep to Scarpa's fascia was 14 mm in the mid abdomen and 5 mm in the lower abdomen (p < 0.05). In 55% of patients the difference in thickness of the mid abdominal and lower abdominal fat was greater than 5 mm, a difference that could lead to a noticeable mismatch and therefore an unfavourable outcome. Results of this study suggest that selectively thinning the fat layer deep to Scarpa's fascia would address potential mismatches and preserve the Scarpa's fascia layer in more than 50% of cases, therefore allowing wounds to be closed with an effective deep tension layer. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Yang, Ye; Soyemi, Olusola O.; Landry, Michelle R.; Soller, Babs R.
2005-01-01
The influence of fat thickness on the diffuse reflectance spectra of muscle in the near infrared (NIR) region is studied by Monte Carlo simulations of a two-layer structure and with phantom experiments. A polynomial relationship was established between the fat thickness and the detected diffuse reflectance. The influence of a range of optical coefficients (absorption and reduced scattering) for fat and muscle over the known range of human physiological values was also investigated. Subject-to-subject variation in the fat optical coefficients and thickness can be ignored if the fat thickness is less than 5 mm. A method was proposed to correct the fat thickness influence. c2005 Optical Society of America.
Suprascarpal fat pad thickness may predict venous drainage patterns in abdominal wall flaps.
Bast, John; Pitcher, Austin A; Small, Kevin; Otterburn, David M
2016-02-01
Abdominal wall flaps are routinely used in reconstructive procedures. In some patients inadequate venous drainage from the deep vein may cause fat necrosis or flap failure. Occasionally the superficial inferior epigastric vessels (SIEV) are of sufficient size to allow for microvascular revascularization. This study looked at the ratio of the sub- and suprascarpal fat layers, the number of deep system perforators, and SIEV diameter to determine any correlation of the fat topography and SIEV. 50 abdominal/pelvic CT angiograms (100 hemiabdomens) were examined in women aged 34-70 years for number of perforators, SIEV diameter, and fat pad thickness above and below Scarpa's fascia. Data was analyzed using multivariate model. The average suprascarpal and subscarpal layers were 18.6 ± 11.5 mm and 6.2 ± 7.2 mm thick, respectively. The average SIEV diameter was 2.06 ± 0.81 mm and the average number of perforators was 2.09 ± 1.03 per hemiabdomen. Hemiabdomens with suprascarpal thickness>23 mm had greater SIEV diameter [2.69 mm vs. 1.8 mm (P < 0.0001)] The fat layer thickness did not correlate with the number of perforators. Neither subscarpal fat thickness nor suprascarpal-to-subscarpal fat layer thickness correlated significantly with SIEV caliber or number of perforators in multivariate model. Suprascarpal fat pad thicker than 23 mm had larger SIEVs irrespective of the number of deep system perforators. This may indicate a cohort of patients at risk of venous congestion from poor venous drainage if only the deep system is revascularized. We recommend harvesting the SIEV in patients with suprascarpal fat pad >23 mm to aid in superficial drainage. © 2015 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Mansouri, C.; L'Huillier, J. P.; Piron, V.
2007-07-01
This work presents results on the modeling of the photon diffusion in a three-layered model, (skin, fat and muscle). The Finite Element method was performed in order to calculate the temporal response of the above-mentioned structure. The thickness of the fat layer was varied from 1 to 15 mm to investigate the effects of increasing fat thickness on the muscle layer absorption coefficient measurements for a source-detector spacing of 30 mm. The simulated time-resolved reflectance data, at different wavelengths, were fitted to the diffusion model to yield the scattering and absorption coefficients of muscle. The errors in estimating muscle absorption coefficients μ α depend on the thickness of the fat layer and its optical properties. In addition, it was shown that it is possible to recover with a good precision (~2.6 % of error) the absorption coefficient of muscle and this up to a thickness of the fat layer not exceeding 4mm. Beyond this limit a correction is proposed in order to make measurements coherent. The muscle-corrected absorption coefficient can be then used to calculate hemoglobin oxygenation.
Effect of Gender on Mechanical Properties of the Plantar Fascia and Heel Fat Pad.
Taş, Serkan
2017-10-01
The purpose of the study was to investigate the plantar fascia and heel fat pad stiffness and thickness parameters in females and compare these values with those of males. This study was carried out in 60 healthy sedentary participants (30 female, 30 male) between the ages of 19 and 50 years. Shear wave velocity (SWV) and thickness of the plantar fascia and heel fat pad were measured with an ultrasonography device. Males had a higher plantar fascia ( P = .037) and heel fat pad ( P = .001) thickness compared with females, but SWV of the plantar fascia ( P = .673), heel fat pad microchamber layer ( P = .240), and heel fat pad macrochamber layer ( P = .636) were similar in both groups. Body mass had a strong correlation with the plantar fascia ( r = 0.64, P < .001) and heel fat pad thickness ( r = 0.68, P < .001). Height had a moderate correlation with the plantar fascia ( r = 0.44, P < .001) and heel fat pad thickness ( r = 0.42, P = .001). Plantar fascia and heel fat pad stiffness were similar in both genders; however, females had a lower plantar fascia and heel fat pad thickness compared with males. Correlation analysis results suggest that higher plantar fascia and heel fat pad thickness in males may be related to higher body mass and height. Level III, Retrospective comparative study.
Sonographic assessment of abdominal fat distribution during the first year of infancy.
Brei, Christina; Much, Daniela; Heimberg, Ellen; Schulte, Verena; Brunner, Stefanie; Stecher, Lynne; Vollhardt, Christiane; Bauer, Jan S; Amann-Gassner, Ulrike; Hauner, Hans
2015-09-01
Longitudinal data regarding the fat distribution in the early postnatal period is sparse. We performed ultrasonography (US) as a noninvasive approach to investigate the development of abdominal subcutaneous (SC) and preperitoneal (PP) fat depots in infants ≤1 y and compared longitudinal US data with skinfold thickness (SFT) measurements and anthropometry in 162 healthy children at 6 wk, 4 mo, and 1 y postpartum. US was found to be a reproducible method for the quantification of abdominal SC and PP adipose tissue (AT) in this age group. Thickness of SC fat layers significantly increased from 6 wk to 4 mo and decreased at 1 y postpartum, whereas PP fat layers continuously increased. Girls had a significantly higher SC fat mass compared to boys, while there was no sex-specific difference in PP fat thickness. SC fat layer was strongly correlated with SFT measurements, while PP fat tissue was only weakly correlated with anthropometric measures. US is a feasible and reproducible method for the quantification of abdominal fat mass in infants ≤1 y of age. PP and SC fat depots develop differentially during the first year of life.
Anatomical study of superficial fascia and localized fat deposits of abdomen.
Kumar, Pramod; Pandey, Arvind K; Kumar, Brijesh; Aithal, Shrinivas K
2011-09-01
The development of liposuction and abdominoplasty has renewed interest in the anatomy of the localized fat deposits (LFD) areas of the abdomen. This study aims at ascertaining the gross anatomy of superficial fascia and the localized fat deposits of abdomen. Eight adult cadavers (four males and four females) were dissected. Attachments, number of layers of fascia and colour, shape and maximum size of the fat lobules in loin, and upper and lower abdomen were noted. Thickness of deep membranous layer of superficial fascia of upper abdomen and lower abdomen were measured by metal casing electronic digital calipers, with resolution being 10 μm. The independent sample t-test, ANOVA for comparison and Pearson coefficient for correlation were used. Superficial fascia of the abdomen was multilayered in the midline and number of layers reduced laterally. The shape, size, color, and arrangement of fat lobules were different in different locations. The thickness of the fascia of the lower abdomen in males (mean 528.336 ± SE38.48) was significantly (P < 0.041) more than that in females. (Mean 390.822 ± SE36.24). Pearson correlation between thickness of the membranous layer of the upper and lower abdomen revealed moderately positive correlation (r=0.718; P<0.045). The LFD in the central region of the abdomen corresponds to the area of multilayered fascia with smaller fat lobules. The relatively thinner supporting fascia of the lower abdomen in females may be responsible for excessive bulges of the lower abdomen. The fat lobule anatomy at different sites under study was different.
Does the Deep Layer of the Deep Temporalis Fascia Really Exist?
Li, Hui; Li, Kaide; Jia, Wenhao; Han, Chaoying; Chen, Jinlong; Liu, Lei
2018-04-14
It has been widely accepted that a split of the deep temporal fascia occurs approximately 2 to 3 cm above the zygomatic arch and extends into the superficial and deep layers. The deep layer of the deep temporal fascia is between the superficial temporal fat pad and the temporal muscle. However, during procedures, the authors noted the absence of the deep layer of the deep temporal fascia between the superficial temporal fat pad and the temporal muscle. This prospective study was conducted to clarify the presence or absence of a deep layer of the deep temporal fascia. Anatomic layers of the soft tissues of the temporal region, with reference to the deep temporal fascia, were investigated in 130 cases operated on for zygomaticofacial fractures using the supratemporal approach from June 2013 to June 2017. Of 130 surgeries, the authors found the absence of a thick, obviously identifiable, fascial layer between the superficial temporal fat pad and the temporal muscle. In fact, the authors found nothing above the temporal muscle in most cases. In a few cases, the authors observed only a small amount of scattered loose connective tissue between the superficial temporal fat pad and the temporal muscle. This clinical study showed the absence of a thick, obviously identifiable, fascial layer between the superficial temporal fat pad and the temporal muscle, which suggests that a "deep layer of the deep temporal fascia" might not exist. Copyright © 2018. Published by Elsevier Inc.
Optimization of Fat-Reduced Puff Pastry Using Response Surface Methodology.
Silow, Christoph; Zannini, Emanuele; Axel, Claudia; Belz, Markus C E; Arendt, Elke K
2017-02-22
Puff pastry is a high-fat bakery product with fat playing a key role, both during the production process and in the final pastry. In this study, response surface methodology (RSM) was successfully used to evaluate puff pastry quality for the development of a fat-reduced version. The technological parameters modified included the level of roll-in fat, the number of fat layers (50-200) and the final thickness (1.0-3.5 mm) of the laminated dough. Quality characteristics of puff pastry were measured using the Texture Analyzer with an attached Extended Craft Knife (ECK) and Multiple Puncture Probe (MPP), the VolScan and the C-Cell imaging system. The number of fat layers and final dough thickness, in combination with the amount of roll-in fat, had a significant impact on the internal and external structural quality parameters. With technological changes alone, a fat-reduced (≥30%) puff pastry was developed. The qualities of fat-reduced puff pastries were comparable to conventional full-fat (33 wt %) products. A sensory acceptance test revealed no significant differences in taste of fatness or 'liking of mouthfeel'. Additionally, the fat-reduced puff pastry resulted in a significant ( p < 0.05) positive correlation to 'liking of flavor' and overall acceptance by the assessors.
Optimization of Fat-Reduced Puff Pastry Using Response Surface Methodology
Silow, Christoph; Zannini, Emanuele; Axel, Claudia; Belz, Markus C. E.; Arendt, Elke K.
2017-01-01
Puff pastry is a high-fat bakery product with fat playing a key role, both during the production process and in the final pastry. In this study, response surface methodology (RSM) was successfully used to evaluate puff pastry quality for the development of a fat-reduced version. The technological parameters modified included the level of roll-in fat, the number of fat layers (50–200) and the final thickness (1.0–3.5 mm) of the laminated dough. Quality characteristics of puff pastry were measured using the Texture Analyzer with an attached Extended Craft Knife (ECK) and Multiple Puncture Probe (MPP), the VolScan and the C-Cell imaging system. The number of fat layers and final dough thickness, in combination with the amount of roll-in fat, had a significant impact on the internal and external structural quality parameters. With technological changes alone, a fat-reduced (≥30%) puff pastry was developed. The qualities of fat-reduced puff pastries were comparable to conventional full-fat (33 wt %) products. A sensory acceptance test revealed no significant differences in taste of fatness or ‘liking of mouthfeel’. Additionally, the fat-reduced puff pastry resulted in a significant (p < 0.05) positive correlation to ‘liking of flavor’ and overall acceptance by the assessors. PMID:28231095
Wanner, G; Theimer, R R
1978-01-01
Spherosomes (oleosomes) of cotyledons of rape (Brassica napus L.), sunflower (Helianthus annuus L.), and watermelon (Citrullus vulgaris, Schrad.) seedlings are delimited by a "half unit membrane" that appears to be continuous with each of the osmiophilic layers of a tripartite unit membrane forming a handlelike appendix of the spherosomes. Prior to any noticeable utilization of the spherosomal storage fat, ribosomes were found to be attached to these "handles". At later stages appendices of the spherosomes are smooth, showing a diameter of about 22 nm that greatly exceeds the thickness of any other unit membrane profiles identical in structure and diameter osomes appears to be continuous with the thick lipid layer of the handles. In intermediate stages of fat depletion the spherosomal bodies become invaginated with cytoplasmic material. Finally vesicles with cytoplasmic contents surrounded by a membrane with a typically thick lipid layer are left in the cells. Membrane profiles indentical in structure and diameter to the spherosomal appendices were also present in electron micrographs of the lipolytic membrane fraction recovered from sucrose density gradients after centrifugation of a microsomal cell fraction. The ultrastructural observations are taken for evidence that the spherosomal appendices represent the lipase-carrying membranes isolated previously (Theimer and Rosnitschek, 1978). A novel hypothesis for development and utilization of fat-storing spherosomes is also proposed.
Evaluation of alignment error due to a speed artifact in stereotactic ultrasound image guidance.
Salter, Bill J; Wang, Brian; Szegedi, Martin W; Rassiah-Szegedi, Prema; Shrieve, Dennis C; Cheng, Roger; Fuss, Martin
2008-12-07
Ultrasound (US) image guidance systems used in radiotherapy are typically calibrated for soft tissue applications, thus introducing errors in depth-from-transducer representation when used in media with a different speed of sound propagation (e.g. fat). This error is commonly referred to as the speed artifact. In this study we utilized a standard US phantom to demonstrate the existence of the speed artifact when using a commercial US image guidance system to image through layers of simulated body fat, and we compared the results with calculated/predicted values. A general purpose US phantom (speed of sound (SOS) = 1540 m s(-1)) was imaged on a multi-slice CT scanner at a 0.625 mm slice thickness and 0.5 mm x 0.5 mm axial pixel size. Target-simulating wires inside the phantom were contoured and later transferred to the US guidance system. Layers of various thickness (1-8 cm) of commercially manufactured fat-simulating material (SOS = 1435 m s(-1)) were placed on top of the phantom to study the depth-related alignment error. In order to demonstrate that the speed artifact is not caused by adding additional layers on top of the phantom, we repeated these measurements in an identical setup using commercially manufactured tissue-simulating material (SOS = 1540 m s(-1)) for the top layers. For the fat-simulating material used in this study, we observed the magnitude of the depth-related alignment errors resulting from the speed artifact to be 0.7 mm cm(-1) of fat imaged through. The measured alignment errors caused by the speed artifact agreed with the calculated values within one standard deviation for all of the different thicknesses of fat-simulating material studied here. We demonstrated the depth-related alignment error due to the speed artifact when using US image guidance for radiation treatment alignment and note that the presence of fat causes the target to be aliased to a depth greater than it actually is. For typical US guidance systems in use today, this will lead to delivery of the high dose region at a position slightly posterior to the intended region for a supine patient. When possible, care should be taken to avoid imaging through a thick layer of fat for larger patients in US alignments or, if unavoidable, the spatial inaccuracies introduced by the artifact should be considered by the physician during the formulation of the treatment plan.
Downie, Jeanine; Kaspar, Miroslav
2016-04-01
Noninvasive body shaping methods seem to be an ascending part of the aesthetics market. As a result, the pressure to develop reliable methods for the collection and presentation of their results has also increased. The most used techniques currently include ultrasound measurements of fat thickness in the treated area, caliper measurements, bioimpedance-based scale measurements or circumferential tape measurements. Although these are the most used techniques, almost all of them have some limitations in reproducibility and/or accuracy. This study shows Magnetic Resonance Imaging (MRI) as the new method for the presentation of results in the body shaping industry. Six subjects were treated by a contactless selective radiofrequency device (BTL Vanquish ME, BTL Industries Inc., Boston, MA). The MRI fat thickness was measured at the baseline and at 4-weeks following the treatment. In addition to MRI images and measurements, digital photographs and anthropometric evaluations such as weight, abdominal circumference, and caliper fat thickness measurements were recorded. Abdominal fat thickness measurements from the MRI were performed from the same slices determined by the same tissue artefacts. The MRI fat thickness difference between the baseline measurement and follow up visit showed an average reduction of 5.36 mm as calculated from the data of 5 subjects. One subject dropped out of study due to non-study related issues. The results were statistically significant based on the Student's T-test evaluation. Magnetic resonance imaging abdominal fat thickness measurements seems to be the best method for the evaluation of fat thickness reduction after non-invasive body shaping treatments. In this study, this method shows average fat thickness reduction of 5.36 mm while the weight of the subjects didn't change significantly. A large spot size measuring 1317 cm(2) (204 square inches) covers the abdomen flank to flank. The average thickness of 5.36 mm of the fat layer reduced under the applicator translates into significant cumulative circumferential reduction. The reduction was not related with dieting.
Kanezaki, Akio; Hirata, Akimasa; Watanabe, Soichi; Shirai, Hiroshi
2010-08-21
The present study describes theoretical parametric analysis of the steady-state temperature elevation in one-dimensional three-layer (skin, fat and muscle) and one-layer (skin only) models due to millimeter-wave exposure. The motivation of this fundamental investigation is that some variability of warmth sensation in the human skin has been reported. An analytical solution for a bioheat equation was derived by using the Laplace transform for the one-dimensional human models. Approximate expressions were obtained to investigate the dependence of temperature elevation on different thermal and tissue thickness parameters. It was shown that the temperature elevation on the body surface decreases monotonically with the blood perfusion rate, heat conductivity and heat transfer from the body to air. Also revealed were the conditions where maximum and minimum surface temperature elevations were observed for different thermal and tissue thickness parameters. The surface temperature elevation in the three-layer model is 1.3-2.8 times greater than that in the one-layer model. The main reason for this difference is attributed to the adiabatic nature of the fat layer. By considering the variation range of thermal and tissue thickness parameters which causes the maximum and minimum temperature elevations, the dominant parameter influencing the surface temperature elevation was found to be the heat transfer coefficient between the body surface and air.
NASA Astrophysics Data System (ADS)
Tetreault, J. L.; Buiter, S. J. H.
2014-07-01
Allochthonous accreted terranes are exotic geologic units that originated from anomalous crustal regions on a subducting oceanic plate and were transferred to the overriding plate during subduction by accretionary processes. The geographical regions that eventually become accreted allochthonous terranes include island arcs, oceanic plateaus, submarine ridges, seamounts, continental fragments, and microcontinents. These future allochthonous terranes (FATs) contribute to continental crustal growth, subduction dynamics, and crustal recycling in the mantle. We present a review of modern FATs and their accreted counterparts based on available geological, seismic, and gravity studies and discuss their crustal structure, geological origin, and bulk crustal density. Island arcs have an average crustal thickness of 26 km, average bulk crustal density of 2.79 g cm-3, and have 3 distinct crustal units overlying a crust-mantle transition zone. Oceanic plateaus and submarine ridges have an average crustal thickness of 21 km and average bulk crustal density of 2.84 g cm-3. Continental fragments presently on the ocean floor have an average crustal thickness of 25 km and bulk crustal density of 2.81 g cm-3. Accreted allochthonous terranes can be compared to these crustal compilations to better understand which units of crust are accreted or subducted. In general, most accreted terranes are thin crustal units sheared off of FATs and added onto the accretionary prism, with thicknesses on the order of hundreds of meters to a few kilometers. In addition many island arcs, oceanic plateaus, and submarine ridges were sheared off in the subduction interface and underplated onto the overlying continent. And other times we find evidence of collision leaving behind accreted terranes 25 to 40 km thick. We posit that rheologically weak crustal layers or shear zones that were formed when the FATs were produced can be activated as detachments during subduction, allowing parts of the FAT crust to accrete and others to accrete. In many modern FATs on the ocean floor, a sub-crustal layer of high seismic velocities, interpreted as ultramafic material, could serve as a detachment or delaminate during subduction.
NASA Astrophysics Data System (ADS)
Tetreault, J. L.; Buiter, S. J. H.
2014-12-01
Allochthonous accreted terranes are exotic geologic units that originated from anomalous crustal regions on a subducting oceanic plate and were transferred to the overriding plate by accretionary processes during subduction. The geographical regions that eventually become accreted allochthonous terranes include island arcs, oceanic plateaus, submarine ridges, seamounts, continental fragments, and microcontinents. These future allochthonous terranes (FATs) contribute to continental crustal growth, subduction dynamics, and crustal recycling in the mantle. We present a review of modern FATs and their accreted counterparts based on available geological, seismic, and gravity studies and discuss their crustal structure, geological origin, and bulk crustal density. Island arcs have an average crustal thickness of 26 km, average bulk crustal density of 2.79 g cm-3, and three distinct crustal units overlying a crust-mantle transition zone. Oceanic plateaus and submarine ridges have an average crustal thickness of 21 km and average bulk crustal density of 2.84 g cm-3. Continental fragments presently on the ocean floor have an average crustal thickness of 25 km and bulk crustal density of 2.81 g cm-3. Accreted allochthonous terranes can be compared to these crustal compilations to better understand which units of crust are accreted or subducted. In general, most accreted terranes are thin crustal units sheared off of FATs and added onto the accretionary prism, with thicknesses on the order of hundreds of meters to a few kilometers. However, many island arcs, oceanic plateaus, and submarine ridges were sheared off in the subduction interface and underplated onto the overlying continent. Other times we find evidence of terrane-continent collision leaving behind accreted terranes 25-40 km thick. We posit that rheologically weak crustal layers or shear zones that were formed when the FATs were produced can be activated as detachments during subduction, allowing parts of the FAT crust to accrete and others to subduct. In many modern FATs on the ocean floor, a sub-crustal layer of high seismic velocities, interpreted as ultramafic material, could serve as a detachment or delaminate during subduction.
Gasperoni, C; Salgarello, M
1995-01-01
The liposuction technique has changed greatly over the years. In 1989, the authors presented subdermal superficial liposuction which treats the superficial fat layer and yields better skin retraction. With this technique the surgeon can treat thin adipose layers to obtain better results in more cases than the traditional liposuction technique. The technique can be used in cases with difficult skin adjustment and in secondary cases when "deep only" liposuction has been performed and there were residual adiposities. Subdermal superficial liposuction evolved so that one could obtain good skin retraction by performing massive liposuction of all the fat layers. The authors named this technique MALL (Massive All Layer Liposuction). The technique is applied in body areas where the fat layer is very thick and stretches the skin because of its volume and weight such as in the abdomen, posterior arms, and internal surface of the upper third of the thighs. MALL liposuction drastically reduces the indications for abdominoplasty and inner thigh and arm dermolipectomies. Knowledge of the anatomy of the subcutaneous fat and the superficial fascial system allows one to explain the subdermal superficial liposuction from an anatomical point of view, to perform a more rational and effective procedure, and to differentiate the technique depending on the area of the body.
Body fat distribution of overweight females with a history of weight cycling.
Wallner, S J; Luschnigg, N; Schnedl, W J; Lahousen, T; Sudi, K; Crailsheim, K; Möller, R; Tafeit, E; Horejsi, R
2004-09-01
Weight cycling may cause a redistribution of body fat to the upper body fat compartments. We investigated the distribution of subcutaneous adipose tissue (SAT) in 30 overweight women with a history of weight-cycling and age-matched controls (167 normal weight and 97 overweight subjects). Measurements of SAT were performed using an optical device, the Lipometer. The SAT topography describes the thicknesses of SAT layers at 15 anatomically well-defined body sites from neck to calf. The overweight women with a history of weight cycling had significantly thicker SAT layers on the upper body compared to the overweight controls, but even thinner SAT layers on their legs than the normal weight women. An android fat pattern was attributed to overweight females and, even more pronounced, to the weight cyclers. The majority of normal weight women showed a gynoid fat pattern. Using stepwise discriminant analysis, 89.0% of all weight cyclers and overweight controls could be classified correctly into the two groups. These findings show the importance of normal weight maintenance as a health-promoting factor.
Automated Discrimination Method of Muscular and Subcutaneous Fat Layers Based on Tissue Elasticity
NASA Astrophysics Data System (ADS)
Inoue, Masahiro; Fukuda, Osamu; Tsubai, Masayoshi; Muraki, Satoshi; Okumura, Hiroshi; Arai, Kohei
Balance between human body composition, e.g. bones, muscles, and fat, is a major and basic indicator of personal health. Body composition analysis using ultrasound has been developed rapidly. However, interpretation of echo signal is conducted manually, and accuracy and confidence in interpretation requires experience. This paper proposes an automated discrimination method of tissue boundaries for measuring the thickness of subcutaneous fat and muscular layers. A portable one-dimensional ultrasound device was used in this study. The proposed method discriminated tissue boundaries based on tissue elasticity. Validity of the proposed method was evaluated in twenty-one subjects (twelve women, nine men; aged 20-70 yr) at three anatomical sites. Experimental results show that the proposed method can achieve considerably high discrimination performance.
Mustafa, Fatin Hamimi; Jones, Peter W; McEwan, Alistair L
2017-01-11
Under-nutrition in neonates is closely linked to low body fat percentage. Undernourished neonates are exposed to immediate mortality as well as unwanted health impacts in their later life including obesity and hypertension. One potential low cost approach for obtaining direct measurements of body fat is near-infrared (NIR) interactance. The aims of this study were to model the effect of varying volume fractions of melanin and water in skin over NIR spectra, and to define sensitivity of NIR reflection on changes of thickness of subcutaneous fat. GAMOS simulations were used to develop two single fat layer models and four complete skin models over a range of skin colour (only for four skin models) and hydration within a spectrum of 800-1100 nm. The thickness of the subcutaneous fat was set from 1 to 15 mm in 1 mm intervals in each model. Varying volume fractions of water in skin resulted minimal changes of NIR intensity at ranges of wavelengths from 890 to 940 nm and from 1010 to 1100 nm. Variation of the melanin volume in skin meanwhile was found to strongly influence the NIR intensity and sensitivity. The NIR sensitivities and NIR intensity over thickness of fat decreased from the Caucasian skin to African skin throughout the range of wavelengths. For the relationship between the NIR reflection and the thickness of subcutaneous fat, logarithmic relationship was obtained. The minimal changes of NIR intensity values at wavelengths within the ranges from 890 to 940 nm and from 1010 to 1100 nm to variation of volume fractions of water suggests that wavelengths within those two ranges are considered for use in measurement of body fat to solve the variation of hydration in neonates. The stronger influence of skin colour on NIR shows that the melanin effect needs to be corrected by an independent measurement or by a modeling approach. The logarithmic response obtained with higher sensitivity at the lower range of thickness of fat suggests that implementation of NIRS may be suited for detecting under-nutrition and monitoring nutritional interventions for malnutrition in neonates in resource-constrained communities.
Scheuble, Nathalie; Lussi, Micha; Geue, Thomas; Carrière, Frédéric; Fischer, Peter
2016-10-10
Delayed fat digestion might help to fight obesity. Fat digestion begins in the stomach by adsorption of gastric lipases to oil/water interfaces. In this study we show how biopolymer covered interfaces can act as a physical barrier for recombinant dog gastric lipase (rDGL) adsorption and thus gastric lipolysis. We used β-lactoglobulin (β-lg) and thermosensitive methylated nanocrystalline cellulose (metNCC) as model biopolymers to investigate the role of interfacial fluid dynamics and morphology for interfacial displacement processes by rDGL and polysorbate 20 (P20) under gastric conditions. Moreover, the influence of the combination of the flexible β-lg and the elastic metNCC was studied. The interfaces were investigated combining interfacial techniques, such as pendant drop, interfacial shear and dilatational rheology, and neutron reflectometry. Displacement of biopolymer layers depended mainly on the fluid dynamics and thickness of the layers, both of which were drastically increased by the thermal induced gelation of metNCC at body temperature. Soft, thin β-lg interfaces were almost fully displaced from the interface, whereas the composite β-lg-metNCC layer thermogelled to a thick interfacial layer incorporating β-lg as filler material and therefore resisted higher shear forces than a pure metNCC layer. Hence, with metNCC alone lipolysis by rDGL was inhibited, whereas the layer performance could be increased by the combination with β-lg.
MALL liposuction: the natural evolution of subdermal superficial liposuction.
Gasperoni, C; Salgarello, M
1994-01-01
Subdermal superficial liposuction, first presented by the authors at the ISAPS Congress at Zurich in 1989, is performed with thin three-hole Mercedes cannulas (diameter ranges from 1.8 to 2 mm) to treat small and secondary adiposities and to allow better skin retraction. Suction of the subdermal layer of fat reduces the thickness and consistency of the superficial fat and enhances the possibility of skin retraction. In cases where there is a large adiposity of the abdomen, arms, or inner thighs, there is a conspicuous volume of fat whose weight tends to overstretch and to carry the overlying skin downward. In these cases we need to reduce the large fat volume to permit effective skin retraction. Therefore, we apply the principles of traditional liposuction with those of subdermal superficial liposuction to aspirate large amounts of fat from all the adipose layers. We call this technique Massive All Layer Liposuction (MALL). The amount of skin shrinkage after this "defatting" procedure is remarkable and the clinical results are very good. The MALL technique can be applied to other areas as well. In our experience this new liposuction technique has dramatically reduced the indications of abdominoplasties and dermolipectomies of inner thighs and arms.
Kong, Chi-Keung; Wong, Heung-Sang Stephen
2005-12-01
Research has shown that growth retardation among children with quadriplegic cerebral palsy (CP) is often attributed to feeding dysfunction and malnutrition. The study compared weight-for-height values and limb anthropometric composition of nasogastric and gastrostomy tube-fed children with quadriplegic CP with those of orally fed children with quadriplegic CP and normal children, to examine the plausible effects of tube feeding on weight-for-height, fat, and muscle values for children with quadriplegic CP. Triceps, anterior mid-thigh, and medial calf skinfold thicknesses and the corresponding circumferences of the right or less affected side were measured. The subjects consisted of 119 normal children and 62 orally fed and 48 tube-fed children with quadriplegic CP. Body weight and height were recorded. For children with CP whose height could not be measured, height was estimated from the ulna length. Weight-for-height z scores, limb skinfold thicknesses, fat areas, skinfold-corrected muscle girths, and muscle areas of the children were compared. Tube-fed children with CP had normal mean weight-for-height z scores. Weight-for-height z scores of the orally fed children with CP were significantly below those of normal children and tube-fed children with CP. For children with CP, whereas triceps skinfold thickness seemed to predict the mid-upper arm fat area correctly, leg skinfold thicknesses seemed to overestimate the corresponding fat areas. Stepwise multiple regression analysis showed that triceps skinfold thicknesses had good correlation (r = 0.86) and the presence of CP had nonsignificant correlation with mid-upper arm fat areas. Multiple regression analysis of fat areas with skinfold thicknesses and the presence of CP, however, showed that CP was correlated negatively (partial correlation of CP: thigh, -0.45; calf, -0.53) with thigh and calf fat areas. Although skinfold-corrected mid-upper arm muscle girths of children with CP were quite similar to those of normal children, leg muscle girths were much reduced for both orally fed and tube-fed children with CP. The apparent thickening of leg skinfold thicknesses among children with CP probably was attributable to disproportional leg muscle wasting, with resulting reduced internal circumference of the subcutaneous fat layer. For tube-fed children with CP, skinfold thicknesses and fat areas were increased significantly, although their leg skinfold-corrected muscle girths and areas remained reduced. Skinfold thickness may overestimate the fat area in the affected limb with significant muscle wasting for children with CP. The condition was particularly obvious in the leg, where muscle wasting was prominent. Because leg muscles represent approximately one quarter of the normal body weight, low weight-for-height values among children with CP can be caused by leg muscle wasting attributable to disuse atrophy, which is unlikely to be correctable with tube feeding. Tube feeding may improve body weight mainly through fat deposition.
Low-cost near-infrared measurement of subcutaneous fat for newborn malnutrition
NASA Astrophysics Data System (ADS)
McEwan, A. L.; Bian, S.; Gargiulo, G. D.; Morhard, R.; Jones, P.; Mustafa, F. H.; Bek, B. Emily; Jeffery, H. E.
2014-04-01
Low fat composition in newborns exposes them to an immediate risk of increased mortality and morbidity, inhibited physical and cognitive development and to diabetes and obesity diseases in later life. Information about nutritional and dietary status of newborns can be accessed by measuring the amount of fat composition in the body. The functions of subcutaneous fat involve energy storage, thermo-insulation and a physical buffer. Current technologies for newborn body fat monitoring are: a device based on air displacement plethesmography (PeaPod), dual-energy Xray, and underwater weighting. However they are bulky, expensive, immobile, and require technical expertise. We propose an alternative portable measurement system of in-vitro for subcutaneous fat that uses diffuse near-infrared light reflectance measurement system. We also introduce an in-vitro three-layered tissue model mimicking the subcutaneous fat layer in newborns together with a preliminary study to measure fat using dual-wavelength nearinfrared light. Based on the output data from these measurements, we have proposed a suitable transmission and scattering model. This model estimated the amount of reflected light collected by a photodetector after incident light is scattered in several fat layers. Our portable sensor is low cost and does not require training hence it is suitable for mass use in the developing world. It consists of a single LED and two photodetectors (900 nm and 1000 nm). The photodetectors wavelengths were chosen to be sensitive to fat as it exhibits a peak in the wavelength at 930 nm and to water at which exhibits a peak at 980 nm; the latter is used, to remove hydration bias. Results on a porcine tissue model demonstrate differentiation as low as 2 mm fat which is a relevant screening thickness to indicate low percentage body fat.
The effect of abdominal wall morphology on ultrasonic pulse distortion. Part II. Simulations.
Mast, T D; Hinkelman, L M; Orr, M J; Waag, R C
1998-12-01
Wavefront propagation through the abdominal wall was simulated using a finite-difference time-domain implementation of the linearized wave propagation equations for a lossless, inhomogeneous, two-dimensional fluid as well as a simplified straight-ray model for a two-dimensional absorbing medium. Scanned images of six human abdominal wall cross sections provided the data for the propagation media in the simulations. The images were mapped into regions of fat, muscle, and connective tissue, each of which was assigned uniform sound speed, density, and absorption values. Propagation was simulated through each whole specimen as well as through each fat layer and muscle layer individually. Wavefronts computed by the finite-difference method contained arrival time, energy level, and wave shape distortion similar to that in measurements. Straight-ray simulations produced arrival time fluctuations similar to measurements but produced much smaller energy level fluctuations. These simulations confirm that both fat and muscle produce significant wavefront distortion and that distortion produced by fat sections differs from that produced by muscle sections. Spatial correlation of distortion with tissue composition suggests that most major arrival time fluctuations are caused by propagation through large-scale inhomogeneities such as fatty regions within muscle layers, while most amplitude and waveform variations are the result of scattering from smaller inhomogeneities such as septa within the subcutaneous fat. Additional finite-difference simulations performed using uniform-layer models of the abdominal wall indicate that wavefront distortion is primarily caused by tissue structures and inhomogeneities rather than by refraction at layer interfaces or by variations in layer thicknesses.
Alam, Murad; Sadhwani, Divya; Geisler, Amelia; Aslam, Imran; Makin, Inder Raj S; Schlessinger, Daniel I; Disphanurat, Wareeporn; Pongprutthipan, Marisa; Voravutinon, Nataya; Weil, Alexandra; Chen, Brian R; West, Dennis P; Veledar, Emir; Poon, Emily
2018-04-23
Non-invasive fat removal is preferred because of decreased downtime and lower perceived risk. It is important to seek new non-invasive fat removal treatments that are both safe and efficacious. To assess the extent to which carboxytherapy, the insufflation of carbon dioxide gas into subcutaneous fat, results in reduction of fat volume. Randomized, sham-controlled, split-body study. Adults (BMI 22-29) were randomized to receive five weekly infusions of 1000 cc CO 2 to one side of the abdomen, and five sham treatments to the contralateral side. Primary outcome measures were ultrasound measurement of fat layer thickness, as well as total circumference before and after treatment. Sixteen participants completed the study. Ultrasound measurement indicated less fat volume on the sides treated with carboxytherapy one week after the last treatment, (p=0.011), but was not maintained at 28 weeks. Total circumference decreased nominally but not significantly at Week 5 compared to baseline (p=0.0697). Participant body weights did not change over the entire course of the study (p=1.00) LIMITATIONS: Limitations included modest sample size and some sources of error in circumference and fat layer measurements. Carboxytherapy provides a transient decrease in subcutaneous fat that may not persist. Treatment is well-tolerated. Copyright © 2018. Published by Elsevier Inc.
Current distribution in tissues with conducted electrical weapons operated in drive-stun mode.
Panescu, Dorin; Kroll, Mark W; Brave, Michael
2016-08-01
The TASER® conducted electrical weapon (CEW) is best known for delivering electrical pulses that can temporarily incapacitate subjects by overriding normal motor control. The alternative drive-stun mode is less understood and the goal of this paper is to analyze the distribution of currents in tissues when the CEW is operated in this mode. Finite element modeling (FEM) was used to approximate current density in tissues with boundary electrical sources placed 40 mm apart. This separation was equivalent to the distance between drive-stun mode TASER X26™, X26P, X2 CEW electrodes located on the device itself and between those located on the expended CEW cartridge. The FEMs estimated the amount of current flowing through various body tissues located underneath the electrodes. The FEM simulated the attenuating effects of both a thin and of a normal layer of fat. The resulting current density distributions were used to compute the residual amount of current flowing through deeper layers of tissue. Numerical modeling estimated that the skin, fat and skeletal muscle layers passed at least 86% or 91% of total CEW current, assuming a thin or normal fat layer thickness, respectively. The current density and electric field strength only exceeded thresholds which have increased probability for ventricular fibrillation (VFTJ), or for cardiac capture (CCTE), in the skin and the subdermal fat layers. The fat layer provided significant attenuation of drive-stun CEW currents. Beyond the skeletal muscle layer, only fractional amounts of the total CEW current were estimated to flow. The regions presenting risk for VF induction or for cardiac capture were well away from the typical heart depth.
NASA Astrophysics Data System (ADS)
Ohmae, Etsuko; Nishio, Shinichiro; Oda, Motoki; Suzuki, Hiroaki; Suzuki, Toshihiko; Ohashi, Kyoichi; Koga, Shunsaku; Yamashita, Yutaka; Watanabe, Hiroshi
2014-06-01
Near-infrared spectroscopy (NIRS) has been used for noninvasive assessment of oxygenation in living tissue. For muscle measurements by NIRS, the measurement sensitivity to muscle (S) is strongly influenced by fat thickness (FT). In this study, we investigated the influence of FT and developed a correction curve for S with an optode distance (3 cm) sufficiently large to probe the muscle. First, we measured the hemoglobin concentration in the forearm (n=36) and thigh (n=6) during arterial occlusion using a time-resolved spectroscopy (TRS) system, and then FT was measured by ultrasound. The correction curve was derived from the ratio of partial mean optical path length of the muscle layer
Chatterjee, I; Hagmann, M J; Gandhi, O P
1980-01-01
The electromagnetic energy deposited in a semi-infinite slab model consisting of skin, fat, and muscle layers is calculated for both plane-wave and near-field exposures. The plane-wave spectrum (PWS) approach is used to calculate the energy deposited in the model by fields present due to leakage from equipment using electromagnetic energy. This analysis applies to near-field exposures where coupling of the target to the leakage source can be neglected. Calculations were made for 2,450 MHz, at which frequency the layered slab adequately models flat regions of the human body. Resonant absorption due to layering is examined as a function of the skin and fat thicknesses for plane-wave exposure and as a function of the physical extent of the near-field distribution. Calculations show that for fields that are nearly constant over at least a free-space wavelength, the energy deposition (for skin, fat, and muscle combination that gives resonant absorption) is equal to or less than that resulting from plane-wave exposure, but is appreciably greater than that obtained for a homogeneous muscle slab model.
Abdominal fat thickness measurement using Focused Impedance Method (FIM) - phantom study
NASA Astrophysics Data System (ADS)
Haowlader, Salahuddin; Baig, Tanveer Noor; Siddique-e Rabbani, K.
2010-04-01
Abdominal fat thickness is a risk indicator of heart diseases, diabetes, etc., and its measurement is therefore important from the point of view of preventive care. Tetrapolar electrical impedance measurements (TPIM) could offer a simple and low cost alternative for such measurement compared to conventional techniques using CT scan and MRI, and has been tried by different groups. Focused Impedance Method (FIM) appears attractive as it can give localised information. An intuitive physical model was developed and experimental work was performed on a phantom designed to simulate abdominal subcutaneous fat layer in a body. TPIM measurements were performed with varying electrode separations. For small separations of current and potential electrodes, the measured impedance changed little, but started to decrease sharply beyond a certain separation, eventually diminishing gradually to negligible values. The finding could be explained using the intuitive physical model and gives an important practical information. TPIM and FIM may be useful for measurement of SFL thickness only if the electrode separations are within a certain specific range, and will fail to give reliable results if beyond this range. Further work, both analytical and experimental, are needed to establish this technique on a sound footing.
NASA Astrophysics Data System (ADS)
Wang, Chiao-Yi; Liao, Andy Ying Chi; Sung, Kung Bin
2018-02-01
Collagen provides skin structure integrity and its concentration is related to the severity of scars. The objective of this study is to develop a hand-held and relatively inexpensive system to detect changes of the dermal collagen concentration in vivo. Diffuse reflectance spectroscopy and two-layer diffusion model have often been used to quantify the collagen concentration and other optical properties of the skin. However, the influences of fat and muscle, which are just below the dermis, have not been thoroughly investigated. We applied Monte Carlo simulations to find source-detector separations most sensitive to changes in collagen absorption and identify four wavelengths between 650 nm and 1000 nm suitable for separating influences of other chromophores including melanin, oxyhemoglobin and deoxyhemoglobin. Our tissue model consisted of at least three layers including the epidermis, dermis and subcutaneous fat with an optional forth layer representing the muscle. Results showed that the reflectance of the three-layered tissue model differed significantly from that of the two-layered tissue model, and the additional muscle layer might also influence the reflectance depending on the thickness of the fat layer. In addition, whether scattering coefficients of the epidermis and dermis were the same significantly affected the reflectance. Differences in reflectance due to changes in the collagen concentration were distinct from those due to changes in scattering coefficients and other chromophores. Further in-vivo experiments are ongoing to to validate the proposed approach.
LAM-1 and FAT Genes Control Development of the Leaf Blade in Nicotiana sylvestris.
McHale, NA
1993-01-01
Leaf primordia of the lam-1 mutant of Nicotiana sylvestris grow normally in length but remain bladeless throughout development. The blade initiation site is established at the normal time and position in lam-1 primordia. Anticlinal divisions proceed normally in the outer L1 and L2 layers, but the inner L3 cells fail to establish the periclinal divisions that normally generate the middle mesophyll core. The lam-1 mutation also blocks formation of blade mesophyll from distal L2 cells. This suggests that LAM-1 controls a common step in initiation of blade tissue from the L2 and L3 lineage of the primordium. Another recessive mutation (fat) was isolated in N. sylvestris that induces abnormal periclinal divisions in the mesophyll during blade initiation and expansion. This generates a blade approximately twice its normal thickness by doubling the number of mesophyll cell layers from four to approximately eight. Presumably, the fat mutation defines a negative regulator involved in repression of periclinal divisions in the blade. The lam-1 fat double mutant shows radial proliferation of mesophyll cells at the blade initiation site. This produces a highly disorganized, club-shaped blade that appears to represent an additive effect of the lam-1 and fat mutations on blade founder cells. PMID:12271096
Derin, S; Altun, I; Koseoglu, S; Sahin, C; Yilmaz, M; Akin, F; Sahan, M
2018-05-01
This study aimed to investigate the relationship of epicardial fat thickness with severity of obstructive sleep apnoea, and clinical and polysomnographic parameters, and to determine independent predictors for epicardial fat thickness. A total of 84 patients with a body mass index of less than 30 kg/m2 and suspected sleep-disordered breathing were included in the study. The correlations of epicardial fat thickness with polysomnographic and clinical data, and severity of obstructive sleep apnoea, were investigated. Mean epicardial fat thickness was 3.75 ± 1.07 mm in the study group (n = 62) and 2.97 ± 0.62 mm in the control group (n = 22) (p < 0.001). There were significant positive correlations between epicardial fat thickness and: apnoea/hypopnoea index, oxygen desaturation index 3 and minimum oxygen saturation, as well as with age, body mass index, and neck and waist circumferences. Non-obese obstructive sleep apnoea patients have thicker epicardial fat compared to controls. Oxygen desaturation index 3 has a strong correlation with epicardial fat thickness and is an independent predictor of it.
Effects of Carcass Weight and Back-fat Thickness on Carcass Properties of Korean Native Pigs.
Kim, Gye-Woong; Kim, Hack-Youn
2017-01-01
Our study analyzed the carcass properties of 170 Korean native pigs in relation to carcass weight and back-fat thickness to provide general data for the production and distribution of high quality pig meat. The 70-74 kg group showed highest yield (73.41%). The ≥80 kg group showed the highest thickest back-fat (24.13 mm) ( p <0.05). The ≥80 kg group showed the best quality grade (1.00). Back-fat thickness showed significant differences in the weight among groups ( p <0.05). The ≥25 mm group showed the highest carcass weight (75.93 kg). The thickest back-fat group (≥25 mm) showed the highest yield (73.03%). There were significant differences in back-fat thickness among groups ( p <0.05), and the ≥25 mm group showed the highest thickness back-fat (27.60 mm). We found a strong positive correlation between carcass weight and back-fat thickness (r=0.346) as well as meat quality grade (r=0.739). Back-fat thickness had a relatively strong positive correlation with meat quality grade (r=0.444). Therefore, there are required to manage the breeding through selection of excellent native species for increasing their carcass weight and enhance meat quality.
Effects of Carcass Weight and Back-fat Thickness on Carcass Properties of Korean Native Pigs
2017-01-01
Our study analyzed the carcass properties of 170 Korean native pigs in relation to carcass weight and back-fat thickness to provide general data for the production and distribution of high quality pig meat. The 70-74 kg group showed highest yield (73.41%). The ≥80 kg group showed the highest thickest back-fat (24.13 mm) (p<0.05). The ≥80 kg group showed the best quality grade (1.00). Back-fat thickness showed significant differences in the weight among groups (p<0.05). The ≥25 mm group showed the highest carcass weight (75.93 kg). The thickest back-fat group (≥25 mm) showed the highest yield (73.03%). There were significant differences in back-fat thickness among groups (p<0.05), and the ≥25 mm group showed the highest thickness back-fat (27.60 mm). We found a strong positive correlation between carcass weight and back-fat thickness (r=0.346) as well as meat quality grade (r=0.739). Back-fat thickness had a relatively strong positive correlation with meat quality grade (r=0.444). Therefore, there are required to manage the breeding through selection of excellent native species for increasing their carcass weight and enhance meat quality. PMID:28747824
Estimating body weight and body composition of chickens by using noninvasive measurements.
Latshaw, J D; Bishop, B L
2001-07-01
The major objective of this research was to develop equations to estimate BW and body composition using measurements taken with inexpensive instruments. We used five groups of chickens that were created with different genetic stocks and feeding programs. Four of the five groups were from broiler genetic stock, and one was from sex-linked heavy layers. The goal was to sample six males from each group when the group weight was 1.20, 1.75, and 2.30 kg. Each male was weighed and measured for back length, pelvis width, circumference, breast width, keel length, and abdominal skinfold thickness. A cloth tape measure, calipers, and skinfold calipers were used for measurement. Chickens were scanned for total body electrical conductivity (TOBEC) before being euthanized and frozen. Six females were selected at weights similar to those for males and were measured in the same way. Each whole chicken was ground, and a portion of ground material of each was used to measure water, fat, ash, and energy content. Multiple linear regression was used to estimate BW from body measurements. The best single measurement was pelvis width, with an R2 = 0.67. Inclusion of three body measurements in an equation resulted in R2 = 0.78 and the following equation: BW (g) = -930.0 + 68.5 (breast, cm) + 48.5 (circumference, cm) + 62.8 (pelvis, cm). The best single measurement to estimate body fat was abdominal skinfold thickness, expressed as a natural logarithm. Inclusion of weight and skinfold thickness resulted in R2 = 0.63 for body fat according to the following equation: fat (%) = 24.83 + 6.75 (skinfold, ln cm) - 3.87 (wt, kg). Inclusion of the result of TOBEC and the effect of sex improved the R2 to 0.78 for body fat. Regression analysis was used to develop additional equations, based on fat, to estimate water and energy contents of the body. The body water content (%) = 72.1 - 0.60 (body fat, %), and body energy (kcal/g) = 1.097 + 0.080 (body fat, %). The results of the present study indicated that the composition of a chicken's body could be estimated from the models that were developed.
Histological study of subcutaneous fat at NIR laser treatment of the rat skin in vivo
NASA Astrophysics Data System (ADS)
Yanina, I. Y.; Svenskaya, Yu. I.; Navolokin, N. A.; Matveeva, O. V.; Bucharskaya, A. B.; Maslyakova, G. N.; Gorin, D. A.; Sukhorukov, G. B.; Tuchin, V. V.
2015-07-01
The goal of this work is to quantify impact of in vivo photochemical treatment using indocyanine green (ICG) or encapsulated ICG and NIR laser irradiation through skin of rat with obesity by the follow up tissue sampling and histochemistry. After 1 hour elapsed since 1-min light exposure samples of rat skin with subcutaneous tissue of thickness of 1.5-2.5 mm were taken by surgery from rats within marked 4-zones of the skin site. For hematoxylin-eosin histological examination of excised tissue samples, fixation was carried out by 10%-formaldehyde solution. For ICG and encapsulated ICG subcutaneous injection and subsequent 1-min diode laser irradiation with power density of 8 W/cm2, different necrotic regions with lipolysis of subcutaneous fat were observed. The obtained data can be used for safe layer-by-layer laser treatment of obesity and cellulite.
Gasperoni, C; Salgarello, M; Emiliozzi, P; Gargani, G
1990-01-01
Liposuction is a widely used technique today and indications are that it is becoming even more popular due to new technical refinements. The use of cannulae with a smaller diameter allows suction of the fat immediately under the dermis. The cannula we use to perform this new kind of fat suction is straight and has an external diameter of less than 2 mm. This cannula, the so-called Mercedes cannula, has a bullet tip and a three-hole head. Moreover, the holes are not round but are slit-shaped and oriented in the same plane at 120 degrees. This cannula is specifically designed to produce less trauma. The cannula with one downward-facing orifice is not suitable for suction of the subdermal layer and an upward-facing orifice would be too traumatic. The advantage of this new technique, apart from the possibility of treating patients with very slight adiposity, is to allow an effective skin retraction. When a large amount of fat has already been aspirated, residual deformities can occur. These skin irregularities represent the lack of an effective cutaneous retraction mostly due to the permanence of the subdermal fat. In fact, the presence of a thick subdermal adipose layer decreases the possibility of skin retraction. Therefore, indications for liposuction of the subdermal fat are mainly the slight adiposities and the remnant deformities of a previous liposuction operation. Moreover, this technique is applied to every lipoplasty whenever better skin retraction is needed.
APOA2 Polymorphism in Relation to Obesity and Lipid Metabolism.
Zaki, Moushira Erfan; Amr, Khalda Sayed; Abdel-Hamid, Mohamed
2013-01-01
Objectives. This study aims to analysis the relationship between c.-492T>C polymorphism in APOA2 gene and the risk for obesity in a sample of Egyptian adolescents and investigates its effect on body fat distribution and lipid metabolism. Material and Methods. A descriptive, cross-sectional study was conducted on 303 adolescents. They were 196 obese and 107 nonobese, aged 16-19 years old. Variables examined included body mass index (BMI), waist circumference (WC), waist to hip ratio (WHR), systolic and diastolic blood pressure (BP), body fat percentage (BF%), abdominal visceral fat layer, and dietary intake. Abdominal visceral fat thickness was determined by ultrasonography. The polymorphism in the APOA2 c.-492T>C was analyzed by PCR amplification. Results. Genotype frequencies were in Hardy-Weinberg equilibrium. The frequency of the mutant C allele was significantly higher in obese cases compared to nonobese. After multivariate adjustment, waist, BF% and visceral adipose layer, food consumption, and HDL-C were significantly higher in homozygous allele CC carriers than TT+TC carriers. Conclusions. Homozygous individuals for the C allele had higher obesity risk than carriers of the T allele and had elevated levels of visceral adipose tissue and serum HDL-C. Moreover, the study shows association between the APOA2 c.-492T>C polymorphism and food consumption.
APOA2 Polymorphism in Relation to Obesity and Lipid Metabolism
Zaki, Moushira Erfan; Amr, Khalda Sayed; Abdel-Hamid, Mohamed
2013-01-01
Objectives. This study aims to analysis the relationship between c.-492T>C polymorphism in APOA2 gene and the risk for obesity in a sample of Egyptian adolescents and investigates its effect on body fat distribution and lipid metabolism. Material and Methods. A descriptive, cross-sectional study was conducted on 303 adolescents. They were 196 obese and 107 nonobese, aged 16–19 years old. Variables examined included body mass index (BMI), waist circumference (WC), waist to hip ratio (WHR), systolic and diastolic blood pressure (BP), body fat percentage (BF%), abdominal visceral fat layer, and dietary intake. Abdominal visceral fat thickness was determined by ultrasonography. The polymorphism in the APOA2 c.-492T>C was analyzed by PCR amplification. Results. Genotype frequencies were in Hardy-Weinberg equilibrium. The frequency of the mutant C allele was significantly higher in obese cases compared to nonobese. After multivariate adjustment, waist, BF% and visceral adipose layer, food consumption, and HDL-C were significantly higher in homozygous allele CC carriers than TT+TC carriers. Conclusions. Homozygous individuals for the C allele had higher obesity risk than carriers of the T allele and had elevated levels of visceral adipose tissue and serum HDL-C. Moreover, the study shows association between the APOA2 c.-492T>C polymorphism and food consumption. PMID:24382995
Borruel, Susana; Fernández-Durán, Elena; Alpañés, Macarena; Martí, David; Alvarez-Blasco, Francisco; Luque-Ramírez, Manuel; Escobar-Morreale, Héctor F
2013-03-01
Sexual dimorphism suggests a role for androgens in body fat distribution. Women with polycystic ovary syndrome (PCOS), a mainly androgen excess disorder, often present with abdominal obesity and visceral adiposity. We hypothesized that women with PCOS have a masculinized body fat distribution favoring the deposition of fat in visceral and organ-specific adipose tissue depots. This was a case-control study. The study was conducted at an academic hospital. Women with PCOS (n = 55), women without androgen excess (n = 25), and men (n = 26) presenting with similar body mass index participated in the study. There were no interventions. Ultrasound measurements of adipose tissue depots including sc (minimum and maximum), preperitoneal, ip, mesenteric, epicardial, and perirenal fat thickness were obtained and total body fat mass was estimated using a body fat monitor. Men and patients with PCOS had increased amounts of total body fat compared with control women. Men had increased thickness of intraabdominal adipose tissue depots compared with the control women, with the women with PCOS showing intermediate values that were also higher than those of control women in the case of ip and mesenteric fat thickness and was close to reaching statistical significance in the case of epicardial fat thickness. Women with PCOS also showed increased minimum sc fat thickness compared with the control women. Obesity increased the thickness of all of the adipose tissue depots in the 3 groups of subjects. Women with PCOS have higher global adiposity and increased amounts of visceral adipose tissue compared with control women, especially in the ip and mesenteric depots.
Quantifying the effect of adipose tissue in muscle oximetry by near infrared spectroscopy
Nasseri, Nassim; Kleiser, Stefan; Ostojic, Daniel; Karen, Tanja; Wolf, Martin
2016-01-01
Change of muscle tissue oxygen saturation (StO2), due to exercise, measured by near infrared spectroscopy (NIRS) is known to be lower for subjects with higher adipose tissue thickness. This is most likely not physiological but caused by the superficial fat and adipose tissue. In this paper we assessed, in vitro, the influence of adipose tissue thickness on muscle StO2, measured by NIRS oximeters. We measured StO2 of a liquid phantom by 3 continuous wave (CW) oximeters (Sensmart Model X-100 Universal Oximetry System, INVOS 5100C, and OxyPrem v1.3), as well as a frequency-domain oximeter, OxiplexTS, through superficial layers with 4 different thicknesses. Later, we employed the results to calibrate OxyPrem v1.3 for adipose tissue thickness in-vivo. PMID:27895999
Tell, G S; Evans, G W; Folsom, A R; Shimakawa, T; Carpenter, M A; Heiss, G
1994-05-15
Associations between atherosclerosis and dietary fat and cholesterol have been demonstrated in numerous animal experiments. The relation between these dietary components and atherosclerosis has not previously been reported in a population-based study among human beings. The associations of dietary fat and cholesterol with carotid artery wall thickness (atherosclerosis) were investigated in a population-based study, the Atherosclerosis Risk in Communities (ARIC) Study, from 1987 to 1989. Participants were 2,095 black women, 5,146 white women, 1,318 black men and 4,589 white men, aged 45-64 years, recruited from four US communities: Jackson, Mississippi; Forsyth County, North Carolina; Washington County, Maryland; and Minneapolis, Minnesota. Habitual diet was assessed with a food frequency questionnaire. Wall thickness was measured with B-mode ultrasound. After adjustment for age and energy intake, animal fat, saturated fat, monounsaturated fat, cholesterol, and Keys' score were positively related to wall thickness, while vegetable fat and polyunsaturated fat were inversely related to wall thickness. These associations persisted after further adjustment for smoking and hypertension and were consistent across the four race and sex groups. Thus, elements of habitual dietary intake were consistently associated with carotid artery wall thickness, compatible with their putatively atherogenic and antiatherogenic properties.
Lee, Sung Hyun; Kim, Dongwan; Baek, Min Young; Tchah, Hann; Kim, Yeon Sun; Ryoo, Eell; Kim, Yun Mi
2015-06-01
The aim of this study is to evaluate the relationship between abdominal subcutaneous fat thickness measured by ultrasonography (US) and serum lipid profile and liver transaminases in obese children. One hundred and sixty-six children diagnosed with obesity from May 2001 to December 2013 were included in this study. Data on serum lipid profile and liver transaminases were collected from clinical records. Abdominal subcutaneous fat thickness and grade of hepatic steatosis were evaluated by US. Of the 166 children, 107 were diagnosed with hepatic steatosis by US, 46 with grade I, 56 with grade II, and five children with grade III. According to the grade of hepatic steasosis, the average values of midline abdominal subcutaneous fat thickness and right flank abdominal subcutaneous fat thickness measured 2.9±0.8 cm and 1.9±0.7 cm in the normal group, 3.3±0.8 cm and 2.0±0.7 cm in grade I, 3.8±0.8 cm and 2.3±0.8 cm in grade II, and 4.1±0.8 cm and 2.8±1.4 cm in grade III, respectively. Abdominal subcutaneous fat thickness correlated with grade of hepatic steatosis (p<0.01). In addition, abdominal subcutaneous fat thickness correlated with concentration of serum lipids and liver transaminases in the age group of 12-14 years (p<0.01). Abdominal subcutaneous fat thickness measured by US can be used as a reliable predictor of possible hyperlipidemia and steatohepatitis in children, especially during the adolescent stage.
[Hydrostatic weighing, skinfold thickness, body mass index relationships in high school girls].
Tahara, Y; Yukawa, K; Tsunawake, N; Saeki, S; Nishiyama, K; Urata, H; Katsuno, K; Fukuyama, Y; Michimukou, R; Uekata, M
1995-12-01
A study was conducted to evaluate body composition by hydrostatic weighing, skinfold thickness, and body mass index (BMI) in 102 senior high school girls, aged 15 to 18 in Nagasaki City. Body density measured by the underwater weighing method, was used to determine the fat weight (Fat) and lean body mass (LBM. or fat free weight: FFW) utilizing the formulas by Brozek et al. The results were as follows; 1. Mean values of body density were 1.04428 in the first grade girls, 1.04182 in the second grade, and 1.04185 in the third grade. 2. Mean values of percentage body fat (%Fat) were 23.5% in the first grade, 24.5% in the second and 24.5% in the third. 3. Percentage body fat (%Fat), lean body mass (LBM) and LBM/Height were not significantly with different advance of grade from the first to the third. 4. The correlation coefficients between percent body fat and the sum of two skinfold thicknesses, the sum of three skinfold thicknesses and the sum of seven skinfold thicknesses was 0.78, 0.79, and 0.80 respectively and were all statistically significant (p < 0.001). 5. The correlation coefficients between BMI and the sum of two skinfold thicknesses, the sum of three skinfold thicknesses and the sum of seven skinfold thicknesses was 0.74, 0.74, and 0.74 respectively and were all statistically significant (p < 0.001). 6. Mean values of BMI, Rohrer index and waist-hip ratio (WHR) in all subjects (n = 102) were 20.3, 128.2 and 0.72 respectively.
Santos, Susana; Gaillard, Romy; Oliveira, Andreia; Barros, Henrique; Abrahamse-Berkeveld, Marieke; van der Beek, Eline M; Hofman, Albert; Jaddoe, Vincent WV
2017-01-01
Background Skinfold thickness enables the measurement of overall and regional subcutaneous fatness in infancy and may be associated with total and abdominal body fat in later childhood. We examined the associations of subcutaneous fat in infancy with total and abdominal fat at school-age. Methods In a population-based prospective cohort study among 821 children, we calculated total subcutaneous fat (sum of biceps, triceps, suprailiacal and subscapular skinfold thicknesses) and central-to-total subcutaneous fat ratio (sum of suprailiacal and subscapular skinfold thicknesses/total subcutaneous fat) at 1.5 and 24 months. At 6 years, we measured fat mass index (total fat/height3), central-to-total fat ratio (trunk fat/total fat) and android-to-gynoid fat ratio (android fat/gynoid fat) by dual-energy X-ray absorptiometry and preperitoneal fat mass area by abdominal ultrasound. Results Central-to-total subcutaneous fat ratio at 1.5 months was positively associated with fat mass index and central-to-total fat ratio at 6 years, whereas both total and central-to-total subcutaneous fat ratio at 24 months were positively associated with all childhood adiposity measures (p<0.05). A 1-standard-deviation scores higher total subcutaneous fat at 24 months was associated with an increased risk of childhood overweight (Odds Ratio 1.70 [95% Confidence Interval 1.36, 2.12]). These associations were weaker than those for body mass index and stronger among girls than boys. Conclusions Subcutaneous fat in infancy is positively associated with total and abdominal fat at school-age. Our results also suggest that skinfold thicknesses add little value to estimate later body fat, as compared to body mass index. PMID:27225335
Santos, Susana; Gaillard, Romy; Oliveira, Andreia; Barros, Henrique; Abrahamse-Berkeveld, Marieke; van der Beek, Eline M; Hofman, Albert; Jaddoe, Vincent W V
2016-09-01
Skinfold thickness enables the measurement of overall and regional subcutaneous fatness in infancy and may be associated with total and abdominal body fat in later childhood. We examined the associations of subcutaneous fat in infancy with total and abdominal fat at school-age. In a population-based prospective cohort study among 821 children, we calculated total subcutaneous fat (sum of biceps, triceps, suprailiacal, and subscapular skinfold thicknesses) and central-to-total subcutaneous fat ratio (sum of suprailiacal and subscapular skinfold thicknesses/total subcutaneous fat) at 1.5 and 24 months. At 6 years, we measured fat mass index (total fat/height(3) ), central-to-total fat ratio (trunk fat/total fat), and android-to-gynoid fat ratio (android fat/gynoid fat) by dual-energy X-ray absorptiometry and preperitoneal fat mass area by abdominal ultrasound. Central-to-total subcutaneous fat ratio at 1.5 months was positively associated with fat mass index and central-to-total fat ratio at 6 years, whereas both total and central-to-total subcutaneous fat ratio at 24 months were positively associated with all childhood adiposity measures. A 1-standard-deviation scores higher total subcutaneous fat at 24 months was associated with an increased risk of childhood overweight (odds ratio 1.70, 95% confidence interval 1.36, 2.12). These associations were weaker than those for body mass index and stronger among girls than boys. Subcutaneous fat in infancy is positively associated with total and abdominal fat at school-age. Our results also suggest that skinfold thicknesses add little value to estimate later body fat, as compared with body mass index. © 2016 John Wiley & Sons Ltd.
Secular changes in body dimensions and sexual maturation in children of Arkhangelsk city.
Godina, Elena Z; Khomyakova, Irina A; Zadorozhnaya, Ludmila V
2016-01-01
The aim of the present study was to analyze secular changes in body measurements in children of the Arkhangelsk city from 1988 to 2010. A large number of anthropometric measurements were taken on each individual including height, weight, arm, leg and trunk lengths (estimated), body diameters and circumferences, skinfold thickness. Stages of secondary sex characteristics were also evaluated; data on menarcheal age were collected by status-quo method. It was shown that main differences in stature occurred at puberty while in elder children (16-17-year-olds) no statistically significant differences were found. The same pattern was typical for weight and BMI. Chest circumference significantly increased, particularly in girls. For modern children, changes in body proportions due to a bigger trunk length were typical. There were also significant differences in the distribution of subcutaneous fat layer: in modern children bigger fat accumulation was present on the trunk, particularly in abdomen area, vs. fat layer on the extremities. Process of sexual maturation according to mean ages of development of secondary sex characteristics occurred earlier in modern adolescents, which is more expressed in girls. The results can be interpreted in terms of ongoing secular trend.
Assessment of the Efficacy of Cryolipolysis on Saddlebags: A Prospective Study of 53 Patients.
Adjadj, Lucille; SidAhmed-Mezi, Mounia; Mondoloni, Marine; Meningaud, Jean Paul; Hersant, Barbara
2017-07-01
Cryolipolysis is a noninvasive subcutaneous fat removal technique. Its efficacy has been demonstrated on various fatty areas but not yet on saddlebags. The main objective of this study was to demonstrate the efficacy, patient tolerance, and safety of cryolipolysis on the saddlebags. This prospective study enrolled 53 patients with saddlebags. Patients with a history of liposuction or other surgical procedure on the saddlebag area and those on diet pills were excluded. The primary endpoint was a decrease in fat thickness at 3 and 6 months, as assessed by thigh circumference measurement and by ultrasound evaluation of subcutaneous fat. Pain associated with cryolipolysis was assessed using a visual analogue scale. Body mass index at the different time points and adverse events were recorded. All patients completed a satisfaction questionnaire at the end of the study. At 6 months, there was a mean decrease of 5.63 cm in thigh circumference; the mean decrease in fat layer thickness measured by ultrasound was 1.31 cm. The satisfaction questionnaire showed that 93.75 percent of patients were satisfied with the results. The mean visual analogue scale score was 1.66 of 10 after the session. Reversible skin changes such as postprocedure postinflammatory hyperpigmentation were observed in 8.33 percent of patients. Cryolipolysis is an effective technique for reducing saddlebag fat and is well tolerated by patients. A substantial risk of skin lesions, including postinflammatory hyperpigmentation that resolved after a few months, was observed. Cryolipolysis is a good alternative to liposuction in women with moderate, well-localized saddlebags. Therapeutic, IV.
NASA Astrophysics Data System (ADS)
Cournane, S.; Browne, J. E.; Fagan, A. J.
2012-06-01
A new generation of ultrasound transient elastography (TE) systems have emerged which exploit the well-known correlation between the liver's pathological and mechanical properties through measurements of the Young's elastic modulus; however, little work has been carried out to examine the effect that fatty deposits may have on the TE measurement accuracy. An investigation was carried out on the effects on the measurement accuracy of a TE ultrasound system, the Fibroscan®, caused by overlaying fat layers of varying thickness on healthy liver-mimicking phantoms, simulating in vivo conditions for obese patients. Furthermore, a steatosis effect similar to that in non-alcoholic fatty liver disease (NAFLD) and alcoholic liver disease (ALD) was simulated to investigate its effect on the TE system. A range of novel elastography fat-mimicking materials were developed using 6-10 wt% poly(vinyl alcohol) cryogel capable of achieving a range of acoustic velocities (1482-1530 m s-1) and attenuation coefficients (0.4-1 dB MHz-1 cm-1) for simulating different liver states. Laboratory-based acoustic velocities and attenuation coefficients were measured while the Young's modulus was established through a gold standard compression testing method. A significant variation of the Young's elastic modulus was measured in healthy phantoms with overlaying fat layers of thicknesses exceeding 45 mm, impinging on the scanners region of interest, overestimating the compression tested values by up to 11 kPa in some cases. Furthermore, Fibroscan® measurements of the steatosis phantoms showed a consistent overestimation (˜54%), which strongly suggests that the speed of sound mismatch between that of liver tissue and that assumed by the scanner is responsible for the high clinical cut-offs established in the case of ALD and NAFLD.
Merlotti, C; Ceriani, V; Morabito, A; Pontiroli, A E
2017-05-01
Aim of this review is to compare visceral and subcutaneous fat loss with all available strategies (diet and exercise, weight-loss promoting agents and bariatric surgery). Eighty-nine studies, all full papers, were analyzed to evaluate visceral and subcutaneous fat changes, measured through ultrasound, computerized tomography, magnetic resonance imaging and expressed as thickness, weight, area and volume. Studies were included in a meta-analysis (random-effects model). Intervention effect (absolute and percent changes of visceral and subcutaneous fat) was expressed as standardized mean differences, with 95% confidence intervals. Publication bias was formally assessed. The result was that subcutaneous fat was greater than visceral fat when measured as area, volume and weight, not as thickness; decrease of subcutaneous fat was greater than visceral fat when measured as area, volume and weight, not as thickness; percent decrease of visceral fat was always greater than percent decrease of subcutaneous fat, with no differences between different strategies. No intervention preferentially targets visceral fat. Basal visceral fat depots are smaller than basal subcutaneous fat depots. Visceral fat loss is linked to subcutaneous fat loss. With all strategies, percent decrease of visceral fat prevails on subcutaneous fat loss.
Horejsi, R; Möller, R; Rackl, S; Giuliani, A; Freytag, U; Crailsheim, K; Sudi, K; Tafeit, E
2004-07-01
The new optical device, the lipometer, enables the noninvasive, quick, safe, and precise determination of the thickness of subcutaneous adipose tissue (SAT) layers at any given site of the human body. Fifteen anatomically well-defined body sites from neck to calf describe a SAT topography (SAT-Top) like an individual "fingerprint" of a subject. This SAT-Top was examined in 16 women with polycystic ovary syndrome (PCOS) and compared to the body fat distribution of 87 age-matched healthy controls and 20 type-2 diabetic women. SAT-Top differences of these three groups were described and, to render the possibility of visual comparison, the 15-dimensional body fat information was condensed to a two-dimensional factor plot by factor analysis. All PCOS patients had an android body fat distribution with significantly thinner SAT layers on the legs as compared to healthy controls. Moreover, a hierarchical cluster analysis resulted in two distinctly different groups of PCOS women, a lean (PCOSL) and an obese (PCOSO) cluster: compared to healthy women, lean PCOS patients had significantly lower total SAT development, even though height, weight, and body mass index did not deviate significantly. Especially on the legs, their SAT layers were significantly lowered, indicating a more "apple-like" fat distribution type. Obese PCOS women showed a SAT-Top pattern very similar to that of women with type-2 diabetes, although the mean age difference between these groups was more than 30 years. Compared to healthy controls, the SAT-Top of these obese PCOS patients was strongly shifted into the android direction, appearing as "super-apples" with a significantly increased upper trunk obesity to 237.8% and a significantly decreased leg SAT development to 79.8%. Copyright 2004 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Sajjadi, Amir Y.; Carp, Stefan A.; Manstein, Dieter
2017-02-01
Monitoring phase transition in adipose tissue and formation of lipid crystals is important in Cryo-procedures such as cryosurgery or Selective Cryolipolysis (SC). In this work, we exploited a Near-Infrared Spectroscopy (NIRS) method to monitor the onset of fat freezing/melting. Concurrent measurements using frequency domain NIRS and MR Spectroscopy during cooling/heating were performed on an in vitro porcine skin sample with a thick subcutaneous fat layer in a human MR scanner. The NIRS probe was placed on the skin measuring the average optical scattering of the fatty layer. Two fiber optic temperature probes were inserted in the area of the MRS and NIRS measurements. To further investigate the microscopic features of the phase-transition, an identical cooling/heating procedure was replicated on the same fat tissue while being imaged by Optical Coherence Tomography. The temperature relationships of optical scattering, MRS peak characteristics and OCT reflection intensity were analyzed to find signatures related to the onset of phase transition. The optical scattering in the fatty tissues decreases during the heating and increases by cooling. However, there is an inflexion in the rate of change of the scattering while the phase transition happens in the fatty layer. The methylene fat peaks on the MR Spectrum are also shown to be broadened during the cooling. OCT intensity displays a sharp increase at the transition temperature. The results from multiple samples show two transition points around 5-10 ˚C (cooling) and 15-20 ˚C (heating) through all three methods, demonstrating that adipose tissue phase change can be monitored non-invasively.
Truong, Dennis Q.; Magerowski, Greta; Blackburn, George L.; Bikson, Marom; Alonso-Alonso, Miguel
2013-01-01
Recent studies show that acute neuromodulation of the prefrontal cortex with transcranial direct current stimulation (tDCS) can decrease food craving, attentional bias to food, and actual food intake. These data suggest potential clinical applications for tDCS in the field of obesity. However, optimal stimulation parameters in obese individuals are uncertain. One fundamental concern is whether a thick, low-conductivity layer of subcutaneous fat around the head can affect current density distribution and require dose adjustments during tDCS administration. The aim of this study was to investigate the role of head fat on the distribution of current during tDCS and evaluate whether dosing standards for tDCS developed for adult individuals in general are adequate for the obese population. We used MRI-derived high-resolution computational models that delineated fat layers in five human heads from subjects with body mass index (BMI) ranging from “normal-lean” to “super-obese” (20.9 to 53.5 kg/m2). Data derived from these simulations suggest that head fat influences tDCS current density across the brain, but its relative contribution is small when other components of head anatomy are added. Current density variability between subjects does not appear to have a direct and/or simple link to BMI. These results indicate that guidelines for the use of tDCS can be extrapolated to obese subjects without sacrificing efficacy and/or treatment safety; the recommended standard parameters can lead to the delivery of adequate current flow to induce neuromodulation of brain activity in the obese population. PMID:24159560
[Progress of midfacial fat compartments and related clinical applications].
Wen, Lihong; Wang, Jinhuang; Li, Yang; Liu, Dalie
2018-02-01
To review the research progress of midfacial fat compartments, and to thoroughly understand its current state of the anatomy and the aging morphologic characters of midfacial fat compartments, as well as the current status of clinical applications. The recent literature concerning the midfacial fat compartments and related clinical applications were extensively reviewed and analyzed. Midfacial fat layer has been considered as a fusion and a continuous layer, experiencing a global atrophy when aging. As more anatomical researches have done, recent studies have shown that midfacial fat layer is broadly divided into superficial and deep layers, which are both divided into different fat compartments by fascia, ligaments, or muscles. Midfacial fat compartments tend to atrophy with age, specifically in the deep fat compartments while hypertrophy in the superficial fat compartments. Clinical applications show that fat volumetric restoration with deep medial cheek fat and Ristow's space can restore the appearance of midface effectively. In recent years, the researches of midfacial fat compartments have achieved obvious progress, which will provide new ideas and basis for fat volumetric restoration. Corresponding treatments are selected based on different sites and different layers with different aging changes, reshaping a more youthful midface.
Ayas, Selçuk; Bayraktar, Mesut; Gürbüz, Ayşe; Alkan, Akif; Eren, Sadiye
2012-01-01
Objective: We aimed to evaluate uterine junctional zone thickness, cervical length and bioelectrical impedance analysis of body composition in women with endometriosis. Material and Methods: This is a prospective study conducted in a tertiary teaching hospital. A total of 73 patients were included in the study. Endometriosis was surgically diagnosed in 36 patients (study group). The control group included 37 patients. Main outcome measure(s): Bioelectrical impedance analysis was used to measure body composition. Uterine junctional zone thickness and cervical length were measured by transvaginal ultrasonography. Results: Patients’ characteristics (age, gravida, parity, live baby, age of menarche, lengths of menstrual cycle, percentage of patients with dysmenorrhea, positive family history), body mass index (BMI) (kg/m2), amount of body fat (kg), percentage of body fat were not statistically different between the two groups (p>0.05). The length of menstruation and cervical length were longer in women with endometriosis. Similarly, the inner myometrium was thicker in women with endometriosis than the control group. Conclusion: The relation between endometriosis and demographic features such as age, gravida, parity, gravida, BMI, lengths of the menstrual cycle, age of menarche are controversial. Longer cervical length and thicker inner myometrial layer may be important in the etiopathogenesis of endometriosis. PMID:25207044
Clinical and histopathological results following TriPollar radiofrequency skin treatments.
Kaplan, Haim; Gat, Andrea
2009-06-01
Skin laxity, wrinkles and cellulite are common aesthetic problems associated with the aging process. These symptoms are due to the weakening and thinning of dermal connective tissue and the enlargement of hypodermal fat cells. The aim of this study was to evaluate the safety and efficacy of the TriPollar RF technology in reducing fat and collagen regeneration. Twelve healthy patients underwent weekly treatments on different body sites using the TriPollar technology. Treatment areas were photographed and measured and patient satisfaction was monitored. One abdominal patient consented to a series of TriPollar treatments prior to her scheduled abdominoplasty. A controlled histopathology analysis was performed on skin samples taken during the abdominoplasty procedure. Histopathological examination revealed marked differences between treated and non-treated abdominal skin areas. An increase of 49% in dermal thickness, focal thickening of collagen fibers and focal shrinkage of fat cells was shown following TriPollar treatments. Average patient satisfaction indicated clear satisfaction with the clinical results achieved. The TriPollar is a safe and effective non-invasive technology leading to skin tightening and body shaping. Histology results indicate changes at the dermal and fat layers following TriPollar treatments resulting in increased collagen regeneration and stimulated fat metabolism.
NASA Astrophysics Data System (ADS)
Nishino, Satoshi; Yasuda, Shun
The near infrared ray spectral characteristic of a person’s cheeks was simulated in this paper, and it was confirmed that the spectral characteristic of the cheeks part by the near infrared rays was detected at the subcutaneous fat under 2mm of the skin. Therefore, subcutaneous fat has a great influence at the near infrared ray spectral characteristic. Concretely, when subcutaneous fat thickness is thick, the absorbance falls down, and the spectral characteristic around 1200nm is the same for an acute angle, and becomes the spectral characteristic of the female. On the other hand, increasing the water content to simulate the increase in the thickness of the subcutaneous fat, the light absorbance rises, and the acute angle of the spectral characteristic around 1200nm disappears. The 1200nm characteristic becomes that of the male’s spectral characteristic which shows a rounded form. From the discussion above, it could be verified that a difference in the subcutaneous fat thickness is the factor of the difference in the near infrared ray spectral characteristics between that of a male and female cheek.
Dong, Ding-Hui; Liu, Wen-Yan; Feng, Hai-Bo; Fu, Yi-Li; Huang, Shi; Xiang, Jun-Xi; Lyu, Yi
2015-01-01
Background: Magnetic anchored surgical instruments (MASI), relying on magnetic force, can break through the limitations of the single port approach in dexterity. Individual characteristic abdominal wall thickness (ICAWT) deeply influences magnetic force that determines the safety of MASI. The purpose of this study was to research the abdominal wall characteristics in MASI applied environment to find ICAWT, and then construct an artful method to predict ICAWT, resulting in better safety and feasibility for MASI. Methods: For MASI, ICAWT is referred to the thickness of thickest point in the applied environment. We determined ICAWT through finding the thickest point in computed tomography scans. We also investigated the traits of abdominal wall thickness to discover the factor that can be used to predict ICAWT. Results: Abdominal wall at C point in the middle third lumbar vertebra plane (L3) is the thickest during chosen points. Fat layer thickness plays a more important role in abdominal wall thickness than muscle layer thickness. “BMI-ICAWT” curve was obtained based on abdominal wall thickness of C point in L3 plane, and the expression was as follow: f(x) = P1 × x2 + P2 × x + P3, where P1 = 0.03916 (0.01776, 0.06056), P2 = 1.098 (0.03197, 2.164), P3 = −18.52 (−31.64, −5.412), R-square: 0.99. Conclusions: Abdominal wall thickness of C point at L3 could be regarded as ICAWT. BMI could be a reliable predictor of ICAWT. In the light of “BMI-ICAWT” curve, we may conveniently predict ICAWT by BMI, resulting a better safety and feasibility for MASI. PMID:26228215
Bayrakci Tunay, V; Akbayrak, T; Bakar, Y; Kayihan, H; Ergun, N
2010-02-01
To evaluate and compare the effectiveness of three different noninvasive treatment techniques on fat mass and regional fat thickness of the patients with cellulites. Sixty subjects were randomized into three groups. Group 1 (n = 20) treated with mechanical massage (MM), group 2 (n = 20) treated with manual lymphatic drainage (MLD) and group 3 (n = 20) treated with connective tissue manipulation (CTM) techniques. Subjects were evaluated by using standardized photographs, body composition analyzer (TBF 300) (body weight (BW), body mass index (BMI), fat %, fat mass (FM), fat free mass (FFM), total body water (TBW)), circumference measurement from thigh, waist-hip ratio (WHR), fat thickness measurements from abdomen, suprailium and thigh regions with skin fold caliper. All groups had an improvement in thinning of the subcutaneous fat after the treatment (P < 0.05). Thigh circumference decreased by an average of 0.5 cm in all groups and thigh fat thickness decreased 1.66 mm in Group 1, 2.21 mm in Group 2 and 3.03 mm in Group 3. Abdomen and suprailium fat thicknesses decreased 2.4 and 2.58 mm in Group 1, 1.78 and 2 mm in Group 2 and 1.23 and 0.64 mm in Group 3, respectively. The mean difference in waist-hip ratio was 0.1 cm in all groups. All the treatment techniques are effective in decreasing the regional fat values of the patients with cellulites.
Kok, Hong Kuan; Donnellan, John; Ryan, Davinia; Torreggiani, William C
2013-08-01
Chondromalacia patellae is a common cause of anterior knee pain in young patients and can be detected noninvasively with magnetic resonance imaging (MRI). The purpose of our study was to evaluate the correlation between subcutaneous fat thickness around the knee joint on axial MRIs as a surrogate marker of obesity, with the presence or absence of chondromalacia patellae. A retrospective review was conducted of knee MRIs in 170 patients who satisfied the inclusion criteria. Imaging was performed over a 12-month period on a 1.5T MRI system with a dedicated extremity coil. Two radiologists experienced in musculoskeletal imaging assessed each examination in consensus for the presence or absence of chondromalacia patellae and graded positive studies from 0 (absent) to 3 (full cartilage thickness defect). Measurement of subcutaneous knee fat thickness was obtained on the medial aspect of the knee. MRI findings of chondromalacia patellae were present in 33 patients (19.4%), of which, there were 11 grade 1 lesions (33.3%), 9 grade 2 lesions (27.3%), and 13 grade 3 lesions (39.4%). The mean subcutaneous knee fat thickness was significantly higher in the chondromalacia patellae group for all grades compared with the normal group (P < .001), and there was a significant correlation between subcutaneous knee fat thickness and grades of chondromalacia patellae (R = 0.48 [95% confidence interval, 0.38-0.68]; P < .001). Female patients had thicker subcutaneous knee fat and more severe grades of chondromalacia patellae. Subcutaneous knee fat thickness as a surrogate marker of obesity was positively associated with the presence and severity of chondromalacia patellae on MRI. Copyright © 2013 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
Welch, Daniella; Ndanyo, Laetitia Sungu; Brown, Simon; Agyapong-Badu, Sandra; Warner, Martin; Stokes, Maria; Samuel, Dinesh
2018-05-01
Thigh tissue thickness has not been examined in older females living in extended care in UK as an indicator of musculoskeletal health. This study examined the feasibility of using ultrasound imaging to measure the thickness of superficial (fat) and deep layers (muscle) of the thigh in older females living in extended care. In ten older females in extended care (aged 80-98 years, mean 88 ± 6.8; body mass: 56.5 ± 12.6 kg) images of the anterior thigh (dominant) were taken in supine using B-mode ultrasound imaging. Superficial and deep layers were measured and percentage thickness was calculated. Independent t tests compared data from those in extended care to ten sedentary females living independently (aged 80-90 years, mean 84 ± 3.6; body mass: 61.6 ± 10.0 kg). Thickness of the superficial layers was not significantly different between the two groups (CI -0.017 to 0.815, p = 0.059). However, those living in extended care had greater (p < 0.001) muscle thickness (mean 2.75 ± 0.48 cm) than those living independently (mean 1.83 ± 0.3 cm), which was similarly significant when normalised for body mass (extended care 0.51 ± 0.16; independent living 0.30 ± 0.06). These novel findings showed it is feasible to use ultrasound to measure muscles in older females in extended care and that muscle thickness was larger than in those living independently. The reason for the difference seen between groups would need to be confirmed by a larger study that also examined factors related to risk of sarcopenia and frailty, such as nutrition and physical activity levels.
Liao, Yu-Kai; Tseng, Sheng-Hao
2014-01-01
Accurately determining the optical properties of multi-layer turbid media using a layered diffusion model is often a difficult task and could be an ill-posed problem. In this study, an iterative algorithm was proposed for solving such problems. This algorithm employed a layered diffusion model to calculate the optical properties of a layered sample at several source-detector separations (SDSs). The optical properties determined at various SDSs were mutually referenced to complete one round of iteration and the optical properties were gradually revised in further iterations until a set of stable optical properties was obtained. We evaluated the performance of the proposed method using frequency domain Monte Carlo simulations and found that the method could robustly recover the layered sample properties with various layer thickness and optical property settings. It is expected that this algorithm can work with photon transport models in frequency and time domain for various applications, such as determination of subcutaneous fat or muscle optical properties and monitoring the hemodynamics of muscle. PMID:24688828
Kanazawa, H; Kawai, M; Niwa, F; Hasegawa, T; Iwanaga, K; Ohata, K; Tamaki, A; Heike, T
2014-06-01
Physical growth in neurologically healthy preterm infants affects motor development. This study investigated the separate relationships between muscle and fat in infancy and later motor development and physical growth. Muscle thickness and subcutaneous fat thickness of the anterior thigh were measured using ultrasound images obtained from neurologically healthy preterm infants at birth, 3, 6, 12 and 18 months' corrected age. We also obtained the Pediatric Evaluation of Disability Inventory and Alberta Infant Motor Scale scores at 18 months' corrected age to assess motor ability and motor delay. Thirty preterm infants completed the study protocol. There was a significant positive correlation between motor ability and increments in subcutaneous fat thickness during the first 3 and 6 months' corrected age (r = 0.48 and 0.40, p < 0.05, respectively), but not between motor ability and muscle thickness growth in any of the periods. A secondary, logistic regression analysis showed that increments in subcutaneous fat thickness during the first 3 months were a protective factor for motor delay. Subcutaneous fat accumulation in early infancy is more strongly associated with motor development and delay than muscle growth. ©2014 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
2016-01-01
The effects of reducing pork fat levels from 20% to 15% or 10% by partially substituting pork back fat with wheat sprout fiber in reduced-fat chicken patties were investigated. Approximate composition, energy value, pH, color, cooking loss, reduction in diameter, reduction in thickness, shear force, and sensory properties were determined. Moisture content, ash contents, yellowness of uncooked and cooked reduced-fat chicken patties with wheat sprout were higher than those in the control, while displaying fat content, calorie content, and pH of uncooked and cooked lower in reduced-fat chicken patties than in the control. Cooking loss, reduction in diameter, and reduction in thickness were the highest in the reduced-fat chicken patties with 10% fat level. Cooking loss, reduction in diameter, and reduction in thickness were decreased when fat levels and wheat sprout levels were increased. Control samples without wheat sprout dietary fiber had significantly (p<0.05) higher color and flavor scores compared to reduced-fat chicken patties containing wheat sprout dietary fiber. The overall acceptability of the control and treatment with 15% fat and 2% wheat sprout dietary fiber (T3) was the highest. Therefore, 15% fat level in reduced-fat chicken patties with the addition of 2% wheat sprout dietary fiber can be used to improve the quality and sensory characteristics of regular-fat chicken patties containing 20% fat level. PMID:28115892
Tomaschunas, Maja; Köhn, Ehrhard; Bennwitz, Petra; Hinrichs, Jörg; Busch-Stockfisch, Mechthild
2013-06-01
The effects of variation in fat content (0.1% to 15.8%) and type of fat, using different types of milk, dairy cream, or vegetable fat cream, on sensory characteristics and consumer acceptance of starch-based vanilla model custards were studied. Descriptive analysis with trained panelists and consumer testing with untrained assessors were applied. Descriptive data were related to hedonic data using principal component analysis to determine drivers of liking and disliking. Results demonstrated an increasing effect of fat concerning visual and oral thickness, creamy flavor, and fat-related texture properties, as well as a decreasing effect concerning yellow color and surface shine. A lack of fat caused moderate intensities in pudding-like flavor attributes and an intensive jelly texture. Adding a vegetable fat cream led to lower intensities in attributes yellow color, cooked flavor, thick, and jelly texture, whereas intensities in vegetable fat flavor and fat-related texture properties increased. All consumers favored custards with medium fat contents, being high in pudding-like and vegetable fat flavor as well as in fat-related texture attributes. Nonfat custards were rejected due to jelly texture and moderate intensities in pudding-flavor attributes. High-fat samples were liked by some consumers, but their high intensities in thickness, white color, and creamy flavor also drove disliking for others. © 2013 Institute of Food Technologists®
Kruglikov, Ilja L
2016-01-01
Electrically layered tissue structure significantly modifies distribution of radiofrequency (RF) current in the dermis and in the subcutaneous adipose tissue comparing to that in a homogeneous medium. On the basis of the simple model of RF current distribution in a two-layer skin containing dermis and subcutis, we assess the influence of the dermal thickness on the current density in different skin layers. Under other equal conditions, current density in the dermis is higher for the skin having thinner dermis. This contradicts the main paradigm of the RF theory stating that treatment results are mainly dependent on the maximal temperature reached in a target tissue, since the best short- and long-term clinical results of RF application to the skin were reported in the areas having thicker dermis. To resolve this contradiction, it is proposed that the long-term effect of RF can be realized through a structural modification of the subcutaneous fat depot adjacent to the treated skin area. Stimulation of these cells located near the interface dermis/subcutis will demand the concentration of applied RF energy in this area and will require the optimal arrangement of RF electrodes on the skin surface.
2016-01-01
Electrically layered tissue structure significantly modifies distribution of radiofrequency (RF) current in the dermis and in the subcutaneous adipose tissue comparing to that in a homogeneous medium. On the basis of the simple model of RF current distribution in a two-layer skin containing dermis and subcutis, we assess the influence of the dermal thickness on the current density in different skin layers. Under other equal conditions, current density in the dermis is higher for the skin having thinner dermis. This contradicts the main paradigm of the RF theory stating that treatment results are mainly dependent on the maximal temperature reached in a target tissue, since the best short- and long-term clinical results of RF application to the skin were reported in the areas having thicker dermis. To resolve this contradiction, it is proposed that the long-term effect of RF can be realized through a structural modification of the subcutaneous fat depot adjacent to the treated skin area. Stimulation of these cells located near the interface dermis/subcutis will demand the concentration of applied RF energy in this area and will require the optimal arrangement of RF electrodes on the skin surface. PMID:27493952
Evaluating the association of APOA2 polymorphism with insulin resistance in adolescents.
Zaki, Moushira Erfan; Amr, Khalda Sayed; Abdel-Hamid, Mohamed
2014-12-01
265T>C SNP in the APOA-II gene promoter may be associated with obesity risk and insulin resistance (IR). This study aims to analyze the association between the APOA2 - 265T>C SNP and risk for obesity and IR in adolescents. The study was conducted on 500 adolescents. They were 240 obese and 260 non-obese individuals, aged 16-21 years old. Their mean age was 18.25 ± 2.54 years. Variables examined body weight, height, waist circumference (WC), systolic and diastolic blood pressure (BP), body fat percentage (BF%), and abdominal visceral fat layer. Homeostasis Model Assessment of Insulin Resistance (HOMA-IR) was used as a biomarker for IR. BF% was assessed by body composition analyzer and abdominal visceral fat thickness was determined by ultrasonography. The APOA2 - 265T>C polymorphism genotype was analyzed by PCR amplification of a 273-bp fragment. Genotype frequencies were in Hardy-Weinberg equilibrium. The frequency of the mutant C allele was significantly higher in obese cases than non-obese cases. After multivariate adjustment, waist, BF%, visceral adipose layer and HOMA-IR were significantly higher in homozygous allele CC carriers than TT + TC carriers. Homozygous individuals for the CC allele had statistically higher values of energy intake, total fat (g/day) and saturated fat (SATFAT) than carriers of the T allele. Homozygous individuals for the C allele had higher obesity risk than carriers of the T allele and had elevated levels of visceral adipose tissue. Moreover, the present study shows that the CC polymorphism is associated with the development of IR [OR 1.89 (1.35-2.91), P = .012] and remains significant after adjusting for gender, age and body mass index.
Ultrasonographic, endoscopic and histological appearance of the caecum in clinically healthy cats.
Hahn, Harriet; Freiche, Valérie; Baril, Aurélie; Charpentier, Julie; Desquilbet, Loïc; Le Poder, Sophie; Servely, Jean-Luc; Laloy, Eve; Pey, Pascaline
2017-02-01
Objectives The aim of the study was to describe the ultrasonographic and endoscopic appearance and characteristics of the caecum in asymptomatic cats, and to correlate these findings with histology. Methods Ex vivo ultrasonographic and histologic evaluations of a fresh caecum were initially performed. Then, 20 asymptomatic cats, privately owned or originating from a reproductive colony, were recruited. All cats had an ultrasonographic examination of the ileocaecocolic junction, where the thickness of the caecal wall, ileocolic lymph nodes and the echogenicity of the local fat were assessed. They all underwent a colonoscopy with a macroscopic assessment of the mucosa and biopsies for histology. Results An ultrasonographic hypoechoic nodular inner layer, which corresponded to the coalescence of multiple lymphoid follicles originating from the submucosa and protruding in the mucosa on histology, was visible in all parts of the caecum. The combined mucosa and submucosa was measured ultrasonographically and defined as the follicular layer. Although all cats were asymptomatic, 3/19 cats showed mild caecal inflammation on histology. The most discriminatory ultrasonographic parameter in assessing this subclinical inflammation was the thickness of the follicular layer at the entrance of the caecum, with a cut-off value of 2.0 mm. All cats (20/20) showed some degree of macroscopic 'dimpling' of the caecal mucosa on endoscopy. Conclusions and relevance Lymphoid follicles in the caecal mucosa and submucosa constitute a unique follicular layer on ultrasound. In asymptomatic cats, a subtle, non-clinically relevant inflammation may exist and this is correlated with an increased thickness of the follicular layer on ultrasound. On endoscopy, a 'dimpled aspect' to the caecal mucosa is a normal finding in the asymptomatic cat.
Cabrera-Rego, Julio Oscar; Navarro-Despaigne, Daisy; Staroushik-Morel, Liudmila; Díaz-Reyes, Karel; Lima-Martínez, Marcos M; Iacobellis, Gianluca
Menopausal transition is critical for the development of early, subclinical vascular damage. Multiple factors, such as atherosclerosis, increased epicardial fat, and endothelial dysfunction can play a role. Hence, the objective of this study was the comparison of epicardial adipose tissue and carotid intima media thickness in order to establish the best predictor of carotid stiffness in middle-aged women with endothelial dysfunction. A total of 43 healthy women aged 40-59 years old with endothelial dysfunction previously demonstrated by flow mediated dilation were recruited to have anthropometric, biochemical, hormonal and ultrasound determinations of carotid intima media thickness and epicardial fat thickness. Carotid arterial stiffness parameters (local pulse wave velocity [4.7±0.7 vs 4.8±0.5 vs 5.6±0.5m/s, respectively, p<0.001], pressure strain elastic modulus [55.2±13.4 vs 59.2±11.8 vs 81.9±15.6kPa, respectively, p<0.001], arterial stiffness index β [4.4±1.4 vs 5.0±1.1 vs 6.4±1.3, respectively, p<0.001]) and epicardial fat thickness (2.98±1.4 vs 3.28±1.9 vs 4.70±1.0mm, respectively, p=0.007) showed a significant and proportional increase in the group of late post-menopausal women when compared to early post-menopausal and pre-menopausal groups, respectively. Among body fat markers, epicardial fat was the strongest predictor of local pulse wave velocity, independent of age. In menopausal women with endothelial dysfunction, menopausal transition is associated with increased carotid arterial stiffness and epicardial fat thickness, independent of age. Ultrasound measured epicardial fat was a better independent predictor of arterial stiffness than carotid intima media thickness in these women. Copyright © 2017 Sociedad Española de Arteriosclerosis. Publicado por Elsevier España, S.L.U. All rights reserved.
Safety and efficacy of cryolipolysis for non‐invasive reduction of submental fat
Burns, A. Jay; Zelickson, Brian D.
2015-01-01
Background and Objectives Cryolipolysis has previously received FDA clearance for fat reduction in the abdomen, flanks, and thighs. There is also interest in small volume fat reduction for areas such as the chin, knees, and axilla. This article reports the results of a cryolipolysis pivotal IDE study for reduction of submental fullness. Study Design/Material and Methods A prototype small volume vacuum applicator (CoolMini applicator, CoolSculpting System, ZELTIQ Aesthetics) was used to treat 60 subjects in the submental area. At each treatment visit, a single treatment cycle was delivered at −10°C for 60 minutes, the same temperature and duration used in current commercially‐available cryolipolysis vacuum applicators. At the investigator's discretion, an optional second treatment was delivered 6 weeks after the initial treatment. The primary efficacy endpoint was 80% correct identification of baseline photographs by independent physician review. The primary safety endpoint was monitoring incidence of device‐ and/or procedure‐related serious adverse events. Secondary endpoints included assessment of fat layer thickness by ultrasound and subject satisfaction surveys administered 12 weeks after final cryolipolysis treatment. Results Independent photo review from 3 blinded physicians found 91% correct identification of baseline clinical photographs. Ultrasound data indicated mean fat layer reduction of 2.0 mm. Patient questionnaires revealed 83% of subjects were satisfied, 80% would recommend submental cryolipolysis to a friend, 77% reported visible fat reduction, 77% felt that their appearance improved following the treatment, and 76% found the procedure to be comfortable. No device‐ or procedure‐related serious adverse events were reported. Conclusion The results of this clinical evaluation of 60 patients treated in a pivotal IDE study demonstrate that submental fat can be reduced safely and effectively with a small volume cryolipolysis applicator. Patient surveys revealed that submental cryolipolysis was well‐tolerated, produced visible improvement in the neck contour, and generated high patient satisfaction. These study results led to FDA clearance of cryolipolysis for submental fat treatment. Lasers Surg. Med. 48:3–13, 2016. © 2015 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc. PMID:26607045
Estimating DXA total body fat percentage by lipometer subcutaneous adipose tissue thicknesses.
Tafeit, Erwin; Greilberger, Joachim; Cvirn, Gerhard; Lipp, Rainer Walther; Schnedl, Wolfgang Johann; Jürimäe, Toivo; Jürimäe, Jaak; Wallner-Liebmann, Sandra Johanna
2009-06-01
DXA is an accepted reference method to estimate body composition. However several difficulties in the applicability exist. The equipment is rather expensive, not portable, impractical for measurement of big study populations and it provides a minimal amount of ionizing radiation exposure. The optical device Lipometer (EU Pat.No. 0516251) provides non-invasive, quick, precise and safe measurements of subcutaneous adipose tissue (SAT) layer thicknesses at any site of the human body. Compared to DXA there are some advantages in the Lipometer approach, because this device is portable, quick, not expensive and no radiation is involved. To use these advantages in the field of total body fat% (TBF%) assessment, an acceptable estimation of DXA TBF% by Lipometer SAT thicknesses is necessary, which was the aim of this study. Height, weight, waist and hip circumferences, DXA TBF% and Lipometer SAT thicknesses at fifteen defined body sites were measured in 28 healthy men (age: 33.9 +/- 16.6 years) and 52 healthy women (age: 40.1 +/- 10.7 years). To estimate Lipometer TBF% stepwise multiple regression analysis was applied, using DXA TBF% as dependent variable. Using the fifteen Lipometer SAT thicknesses together with age, height, weight and BMI as independent variables provided the best estimations of Lipometer TBF% for both genders with strong correlations to DXA TBF% (R = 0.985 for males and R = 0.953 for females). The limits of agreement were -2.48% to +2.48% for males and -4.28% to + 4.28% for females. For both genders we received a bias of 0.00%. The results of this paper extend the abilities of the Lipometer by a precise estimation of TBF% using DXA as golden standard.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, Robert Y., E-mail: rx-tang@laurentian.ca; Laamanen, Curtis, E-mail: cx-laamanen@laurentian.ca; McDonald, Nancy, E-mail: mcdnancye@gmail.com
Purpose: Develop a method to subtract fat tissue contributions to wide-angle x-ray scatter (WAXS) signals of breast biopsies in order to estimate the differential linear scattering coefficients μ{sub s} of fatless tissue. Cancerous and fibroglandular tissue can then be compared independent of fat content. In this work phantom materials with known compositions were used to test the efficacy of the WAXS subtraction model. Methods: Each sample 5 mm in diameter and 5 mm thick was interrogated by a 50 kV 2.7 mm diameter beam for 3 min. A 25 mm{sup 2} by 1 mm thick CdTe detector allowed measurements ofmore » a portion of the θ = 6° scattered field. A scatter technique provided means to estimate the incident spectrum N{sub 0}(E) needed in the calculations of μ{sub s}[x(E, θ)] where x is the momentum transfer argument. Values of μ{sup ¯}{sub s} for composite phantoms consisting of three plastic layers were estimated and compared to the values obtained via the sum μ{sup ¯}{sub s}{sup ∑}(x)=ν{sub 1}μ{sub s1}(x)+ν{sub 2}μ{sub s2}(x)+ν{sub 3}μ{sub s3}(x), where ν{sub i} is the fractional volume of the ith plastic component. Water, polystyrene, and a volume mixture of 0.6 water + 0.4 polystyrene labelled as fibphan were chosen to mimic cancer, fat, and fibroglandular tissue, respectively. A WAXS subtraction model was used to remove the polystyrene signal from tissue composite phantoms so that the μ{sub s} of water and fibphan could be estimated. Although the composite samples were layered, simulations were performed to test the models under nonlayered conditions. Results: The well known μ{sub s} signal of water was reproduced effectively between 0.5 < x < 1.6 nm{sup −1}. The μ{sup ¯}{sub s} obtained for the heterogeneous samples agreed with μ{sup ¯}{sub s}{sup ∑}. Polystyrene signals were subtracted successfully from composite phantoms. The simulations validated the usefulness of the WAXS models for nonlayered biopsies. Conclusions: The methodology to measure μ{sub s} of homogeneous samples was quantitatively accurate. Simple WAXS models predicted the probabilities for specific x-ray scattering to occur from heterogeneous biopsies. The fat subtraction model can allow μ{sub s} signals of breast cancer and fibroglandular tissue to be compared without the effects of fat provided there is an independent measurement of the fat volume fraction ν{sub f}. Future work will consist of devising a quantitative x-ray digital imaging method to estimate ν{sub f} in ex vivo breast samples.« less
Anatomical Study of Temporal Fat Compartments and its Clinical Application for Temporal Fat Grafting
Huang, Ru-Lin; Xie, Yun; Wang, Wenjin; Herrler, Tanja; Zhou, Jia; Zhao, Peijuan; Pu, Lee LQ; Li, Qingfeng
2017-01-01
Abstract Background Low satisfaction rates and severe complications are two major limitations for temporal hollowing augmentation using autologous fat grafting. Despite fat compartments in temporal region have been reported, its clinical applied anatomy for fat grafting have not been the subject of studies that show its benefits objectively and statistically. Objectives To investigate temporal fat compartments and relative neurovascular structures in cadavers, developing a safe and effective fat grafting technique for temporal hollowing augmentation. Methods The study was conducted on 8 cadavers (16 temples). The tissue layers, fat compartments, ligaments, and neurovascular structures in the temporal region were analysed. The variables were the number and location of sentinel veins, perforator vessels of the middle temporal vein. Measurements were taken with a digital calliper. Results Two separate fat compartments, the lateral temporal-cheek fat compartment and lateral orbital fat compartment, were found in the subcutaneous layer, and two separate septum compartments, the upper and lower temporal compartment, were found in the loose areolar tissue layer. One sentinel vein and 1 to 6 perforator vessels were found to travel through the subcutaneous tissue layer, traverse the overlapping tissue layers in the lower temporal septum region, and finally join in the middle temporal vein. Conclusions The four fat compartments in the temporal region are ideal receipt sites for fat grafting. The medial border of the junction of the hairline and temporal line is a safe and effective cannula entry site for temporal fat grafting. The anterior half of the lower temporal compartment is a “zone of caution” for temporal fat grafting. PMID:28520850
Swaine, Jillian M; Moe, Andrew; Breidahl, William; Bader, Daniel L; Oomens, Cees W J; Lester, Leanne; O'Loughlin, Edmond; Santamaria, Nick; Stacey, Michael C
2018-02-01
High strain in soft tissues that overly bony prominences are considered a risk factor for pressure ulcers (PUs) following spinal cord impairment (SCI) and have been computed using Finite Element methods (FEM). The aim of this study was to translate a MRI protocol into ultrasound (US) and determine between-operator reliability of expert sonographers measuring diameter of the inferior curvature of the ischial tuberosity (IT) and the thickness of the overlying soft tissue layers on able-bodied (AB) and SCI using real-time ultrasound. Part 1: Fourteen AB participants with a mean age of 36.7 ± 12.09 years with 7 males and 7 females had their 3 soft tissue layers in loaded and unloaded sitting measured independently by 2 sonographers: tendon/muscle, skin/fat and total soft tissue and the diameter of the IT in its short and long axis. Part 2: Nineteen participants with SCI were screened, three were excluded due to abnormal skin signs, and eight participants (42%) were excluded for abnormal US signs with normal skin. Eight SCI participants with a mean age of 31.6 ± 13.6 years and all male with 4 paraplegics and 4 tetraplegics were measured by the same sonographers for skin, fat, tendon, muscle and total. Skin/fat and tendon/muscle were computed. AB between-operator reliability was good (ICC = 0.81-0.90) for 3 soft tissues layers in unloaded and loaded sitting and poor for both IT short and long axis (ICC = -0.028 and -0.01). SCI between-operator reliability was good in unloaded and loaded for total, muscle, fat, skin/fat, tendon/muscle (ICC = 0.75-0.97) and poor for tendon (ICC = 0.26 unloaded and ICC = -0.71 loaded) and skin (ICC = 0.37 unloaded and ICC = 0.10). A MRI protocol was successfully adapted for a reliable 3 soft tissue layer model and could be used in a 2-D FEM model designed to estimate soft tissue strain as a novel risk factor for the development of a PU. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Variational formulation of open-ended coaxial line in contact with layered biological medium.
Alanen, E; Lahtinen, T; Nuutinen, J
1998-10-01
An open-ended coaxial probe designed to measure layered biological media is analyzed with a new method. The probe is considered as an electrostatic circuit element whose capacitance is solved using a stationary functional. The fundamental transverse electric and magnetic field (TEM)-mode and the series of evanescent wavemodes in the coaxial cable are used as basis functions. The field outside the probe is solved using a Hankel transform. The capacitance is calculated for homogeneous materials and two-layer structures and the results are compared with values measured with a phantom model. The method can be easily extended for structures with an arbitrary number of layers. A practical approximation for two-layer cases, originally developed to take into account the effect of subcutaneous fat in skin measurements, is presented and its validity for different combinations of dielectric constants and the thickness of the first layer is demonstrated. The static approximation limits the frequency range, but it covers biological measurements up to 500 MHz. The developed method is accurate and easy to adopt in practice.
Kordi, Ramin; Dehghani, Saeed; Noormohammadpour, Pardis; Rostami, Mohsen; Mansournia, Mohammad Ali
2015-01-01
The aim of this study was to compare the effect of diet and an abdominal resistance training program to diet alone on abdominal subcutaneous fat thickness and waist circumference of overweight and obese women. This randomized clinical trial included 40 overweight and obese women randomly divided into 2 groups: diet only and diet combined with 12 weeks of abdominal resistance training. Waist and hip circumferences and abdominal skin folds of the subjects were measured at the beginning and 12 weeks after the interventions. In addition, abdominal subcutaneous fat thickness of the subjects was measured using ultrasonography. Percentage body fat and lean body mass of all the subjects were also measured using a bioelectric impedance device. After 12 weeks of intervention, the weight of participants in both groups decreased; but the difference between the 2 groups was not significant (P = .45). Similarly, other variables including abdominal subcutaneous fat, waist circumference, hip circumference, body mass index, body fat percentage, and skin fold thickness were reduced in both groups; but there were no significant differences between the groups. This study found that abdominal resistance training besides diet did not reduce abdominal subcutaneous fat thickness compared to diet alone in overweight or obese women. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
Al-Shorman, Alaa; Al-Domi, Hayder; Al-Atoum, Muatasem
2018-06-01
Background Increased carotid intima-media thickness is one of the predictors of future cardiovascular diseases. However, it is still unknown which body composition parameter or anthropometric measure is the best predictor for carotid intima-media thickness change among children and young adolescents. Objective To investigate the associations of body composition and anthropometric measures with carotid intima-media thickness among a group of obese and normal bodyweight schoolchildren. Methods A total of 125 schoolchildren (10-15 years) were recruited from four public schools in Amman, Jordan. Of them, 60 (29 boys and 31 girls) were normal bodyweight students and 65 (35 boys and 30 girls) were obese students. Anthropometric measures, fat mass and fat-free mass were determined. Carotid intima-media thickness of the common artery was measured using high-resolution B-mode ultrasound. Results Compared to normal bodyweight students, obese participants exhibited greater carotid intima-media thickness (mm) (0.45 ± 0.10 vs. 0.38 ± 0.08, p = 0.002) and fat-free mass (kg) (48.01 ± 11.39 vs. 32.65 ±7.65, p < 0.001). Pearson's correlation coefficient and linear regression analysis revealed significant associations ( p≤0.05) between mean carotid intima-media thickness and body mass index, waist circumference, hip circumference, waist-to-hip ratio, fat mass and fat-free mass. Stepwise linear regression analysis revealed that waist circumference was the only measure that was statistically significant ( p ≤ 0.05) with mean carotid intima-media thickness (r 2 = 0.129, p = 0.002). Conclusions Obesity is related to greater carotid intima-media thickness and other cardiovascular risk factors among schoolchildren. Waist circumference is more sensitive in predicting increased carotid intima-media thickness than other body composition or anthropometric measures. Waist circumference measurement in the analysis of future studies assessing the cardiovascular risk among obese children is warranted.
Structure of the integument of southern right whales, Eubalaena australis.
Reeb, Desray; Best, Peter Barrington; Kidson, Susan Hillary
2007-06-01
Skin (integument) anatomy reflects adaptations to particular environments. It is hypothesized that cetacean (whale) integument will show unique anatomical adaptations to an aquatic environment, particularly regarding differences in temperature, density, and pressure. In this study, the gross and histological structure of the southern right whale integument is described and compared with terrestrial mammals and previous descriptions of mysticete (baleen whale) and odontocete (toothed whale) species. Samples were taken of the integument of 98 free-swimming southern right whales, Eubalaena australis, and examined by both light and electron microscopy. Results show that three epidermal layers are present, with the stratum corneum being parakeratotic in nature. As in bowhead whales, southern right whales possess an acanthotic epidermis and a notably thick hypodermis, with epidermal rods and extensive papillomatosis. However, unlike bowhead whales, southern right whales possess an uninterrupted hypodermal layer. Surprisingly, the integument of balaenids (right and bowhead mysticetes) in general is more like that of odontocetes than that of the more closely related balaenopterids (rorqual mysticetes). Similarities to odontocetes were found specifically in the collagen fibers in a fat-free zone of the reticular dermal layer and the elastic fibers in the dermal and hypodermal layers. Callosities, a distinctive feature of this genus, have a slightly thicker stratum corneum and are usually associated with hairs that have innervated and vascularized follicles. These hairs may function as vibrissae, thus aiding in aquatic foraging by allowing rapid detection of changes in prey density. Although the thick insulatory integument makes right whales bulky and slow-moving, it is an adaptation for living in cold water. Epidermal thickness, presence of epidermal rods, and callosities may act as barriers against mechanical injury from bodily contact with conspecifics or hard surfaces in the environment (e.g., rocks, ice). 2007 Wiley-Liss, Inc.
Measurement of subcutaneous adipose tissue development in children by the optical device LIPOMETER
NASA Astrophysics Data System (ADS)
Moeller, Reinhard; Horejsi, Renate; Sudi, Karl; Berg, Aloys; Reibnegger, Gilbert; Tafeit, Erwin
2001-10-01
The new optical device LIPOMETER enables the non-invasive, quick and save determination of the thickness of subcutantous adipose tissue (SAT) layers (in nm) at any site of the human body. The topographic specification of 15 evenly distributed body sites allows the precise measurement of subcutaneous body fat distribution, so called subcutaneous adipose tissue topopgraphy (SAT-Top). SAT-Top was determined in more than 1000 children aging from 7 to 21 yr. We describe the SAT-Top development of these subjects through different age groups and the differences between male and female SAT-Top development in each age group. SAT layer profiles (medians of the 15 body sites) for boys and girls in age group (7-9 yr) show a very similar pattern for both sexes, followed by decreasing SAT layer thicknesses in boys and increasing values in girls in the subsequent age groups. Between age group 3 (11-13 yr) and age group 7 (19- 21 yr) male and female SAT-Top is significantly different in (almost) all body sites. We present a precise description of SAT-Top development in boys and girls, providing a basis for further investigations in different fields such as obesity, sport sciences or metabolic disorders, and suggesting the LIPOMETER technique as an appropriate measurement tool.
Siavash, Mansour; Naseri, Mohsen; Rahimi, Mojgan
2016-01-01
Obesity is a worldwide health problem which is associated with a lot of complications. One of these comorbidities is the metabolic syndrome that is in correlation with abdominal fat thickness and waist circumference. Various methods were used to reduce abdominal fat thickness such as liposuction. A noninvasive method is the topical agent. In this study, we investigated the effectiveness of Arnebia euchroma (AE) ointment on the abdominal fat thickness. This study was a double-blind clinical trial which was done at the endocrinology clinic in Khorshid Hospital, Isfahan, Iran, in 2014. After explaining the procedure and obtaining informed consent, the candidates were randomly divided into the case and control groups. The participants of the case and control groups applied AE ointment or placebo for 6 weeks on their abdominal area. Body mass index, waist and buttock circumference, and abdominal fat thickness were measured in both case and control groups at their first visit and then at the next 2, 4, and 6 weeks. We used t -test for comparing parametric variables between groups, paired t -test for changes from baseline to final, and repeated measure ANOVA for changes at different steps. Sixty female candidates participated in this study (thirty in each group). Ten patients left the study and fifty participants finished the trial. At the end of the study, participants had a significant weight loss (2.96 ± 1.6 kg, P < 0.001) that was slightly more in the case group (3.15 ± 1.5 kg vs. 2.75 ± 1.7, P = 0.375). Abdominal circumference also decreased significantly in the participants (11.3 ± 6.7 cm, P < 0.001), but the changes were more significant in the case group (13.9 vs. 6.5 cm, P = 0.004). Similarly, abdominal fat thickness decreased significantly in the participants (2.3 ± 1.1 cm, P < 0.001), although changes were not significantly different between two groups (2.53 vs. 2.04 cm, P = 0.139). Topical AE ointment can reduce the abdominal fat thickness as well as the waist circumference without causing any side effect.
Sim, Kang Hee; Hwang, Moon Sook; Kim, Sun Young; Lee, Hye Mi; Chang, Ji Yeun; Lee, Moon Kyu
2014-04-01
Longer needle and complicated insulin injection technique such as injecting at a 45-degree angle and making skinfolds may decrease patient compliance to insulin injection therapy. In this light, shorter insulin needles have been recently developed. However, it is necessary to ascertain that such shorter needles are appropriate for Korean patients with diabetes as well. First, the diverse demographic and diabetic features of 156 Korean adults with diabetes were collected by a questionnaire and a device unit of body fat measurement. The skin and subcutaneous fat thicknesses of each subject were measured by Ultrasound device with a 7- to 12-MHz probe. Data were analyzed using analysis of variance and multiple linear regression. The mean skin thickness was 2.29±0.37 mm in the abdomen and 2.00±0.34 mm in the upper arms, and the mean subcutaneous fat thickness was to 10.15±6.54 mm in the abdomen and 5.50±2.68 mm in the upper arms. Our analysis showed that the factors affecting the skin thickness of the abdomen and upper arms were gender and body mass index (BMI), whereas the factors influencing the subcutaneous fat thickness in the abdomen were gender and BMI, and the factors influencing the subcutaneous fat thickness in the upper arms were gender, BMI, and age. Insulin fluids may not appear to be intradermally injected into the abdomen and upper arms at any needle lengths. The risk of intramuscular injection is likely to increase with longer insulin needles and lower BMI. It is recommended to fully inform the patients about the lengths of needles for insulin injections. As for the recommended needle length, the findings of this study indicate that needles as short as 4 mm are sufficient to deliver insulin for Korean patients with diabetes.
Sim, Kang Hee; Kim, Sun Young; Lee, Hye Mi; Chang, Ji Yeun; Lee, Moon Kyu
2014-01-01
Background Longer needle and complicated insulin injection technique such as injecting at a 45-degree angle and making skinfolds may decrease patient compliance to insulin injection therapy. In this light, shorter insulin needles have been recently developed. However, it is necessary to ascertain that such shorter needles are appropriate for Korean patients with diabetes as well. Methods First, the diverse demographic and diabetic features of 156 Korean adults with diabetes were collected by a questionnaire and a device unit of body fat measurement. The skin and subcutaneous fat thicknesses of each subject were measured by Ultrasound device with a 7- to 12-MHz probe. Data were analyzed using analysis of variance and multiple linear regression. Results The mean skin thickness was 2.29±0.37 mm in the abdomen and 2.00±0.34 mm in the upper arms, and the mean subcutaneous fat thickness was to 10.15±6.54 mm in the abdomen and 5.50±2.68 mm in the upper arms. Our analysis showed that the factors affecting the skin thickness of the abdomen and upper arms were gender and body mass index (BMI), whereas the factors influencing the subcutaneous fat thickness in the abdomen were gender and BMI, and the factors influencing the subcutaneous fat thickness in the upper arms were gender, BMI, and age. Insulin fluids may not appear to be intradermally injected into the abdomen and upper arms at any needle lengths. The risk of intramuscular injection is likely to increase with longer insulin needles and lower BMI. Conclusion It is recommended to fully inform the patients about the lengths of needles for insulin injections. As for the recommended needle length, the findings of this study indicate that needles as short as 4 mm are sufficient to deliver insulin for Korean patients with diabetes. PMID:24851206
Duncan, Diane Irvine; Kim, Theresa H. M.; Temaat, Robbin
2016-01-01
Noninvasive fat reduction is claimed by many device manufacturers, but proof of efficacy has been difficult to establish. This prospective study was designed to measure the reduction of fat thickness and actual volume reduction in 20 female patients treated with an external radiofrequency (RF) device. This device combines RF heat, suction coupled vacuum, and oscillating electrical pulses that induce adipocyte death over time. Patients underwent pre- and post-treatment and intercurrent measurements of weight, body mass index, ultrasonic transcutaneous fat thickness, and 2D and 3D Vectra photography with independent calculation of circumferential and volumetric change. Mean transcutaneous ultrasound thickness at reproducible points was 2.78 cm; at 1-month post-treatment, the mean fat thickness was 1.71 cm. At 3-month post-treatment, the mean fat thickness reduction was 39.6%. Vectra circumference measurements were taken at 10-mm intervals, with postural and breathing cycle control. Independent analysis of serial measurements from + 60 to − 70 mm showed mean abdominal circumference measurement of 2.3 cm. Mean abdominal volume loss was 202.4 and 428.5 cc at 1- and 3-month post-treatment, respectively. Scanning electron microscopy confirmed that permanent cell destruction was caused by irreversible electroporation. Pyroptosis appears to be the mechanism of action. PMID:26962636
Duncan, Diane Irvine; Kim, Theresa H M; Temaat, Robbin
2016-10-01
Noninvasive fat reduction is claimed by many device manufacturers, but proof of efficacy has been difficult to establish. This prospective study was designed to measure the reduction of fat thickness and actual volume reduction in 20 female patients treated with an external radiofrequency (RF) device. This device combines RF heat, suction coupled vacuum, and oscillating electrical pulses that induce adipocyte death over time. Patients underwent pre- and post-treatment and intercurrent measurements of weight, body mass index, ultrasonic transcutaneous fat thickness, and 2D and 3D Vectra photography with independent calculation of circumferential and volumetric change. Mean transcutaneous ultrasound thickness at reproducible points was 2.78 cm; at 1-month post-treatment, the mean fat thickness was 1.71 cm. At 3-month post-treatment, the mean fat thickness reduction was 39.6%. Vectra circumference measurements were taken at 10-mm intervals, with postural and breathing cycle control. Independent analysis of serial measurements from + 60 to - 70 mm showed mean abdominal circumference measurement of 2.3 cm. Mean abdominal volume loss was 202.4 and 428.5 cc at 1- and 3-month post-treatment, respectively. Scanning electron microscopy confirmed that permanent cell destruction was caused by irreversible electroporation. Pyroptosis appears to be the mechanism of action.
Tanito, Masaki; Brush, Richard S.; Elliott, Michael H.; Wicker, Lea D.; Henry, Kimberly R.; Anderson, Robert E.
2009-01-01
The fat-1 gene cloned from C. elegans encodes an n-3 fatty acid desaturase that converts n-6 to n-3 PUFA. Mice carrying the fat-1 transgene and wild-type controls were fed an n-3-deficient/n-6-enriched diet [fat-1- safflower oil (SFO) and wt-SFO, respectively]. Fatty acid profiles of rod outer segments (ROS), cerebellum, plasma, and liver demonstrated significantly lower n-6/n-3 ratios and higher docosahexaenoic acid (DHA) levels in fat-1-SFO compared with wt-SFO. When mice were exposed to light stress: 1) the outer nuclear layer (ONL) thickness was reduced; 2) amplitudes of the electroretinogram (ERG) were lower; 3) the number of apoptotic photoreceptor cells was greater; and 4) modification of retinal proteins by 4-hydroxyhexenal (4-HHE), an end-product of n-3 PUFA oxidation was increased in both fat-1-SFO and wt mice fed a regular lab chow diet compared with wt-SFO. The results indicate a positive correlation between the level of DHA, the degree of n-3 PUFA lipid peroxidation, and the vulnerability of the retina to photooxidative stress. In mice not exposed to intense light, the reduction in DHA resulted in reduced efficacy in phototransduction gain steps, while no differences in the retinal morphology or retinal biochemistry. These results highlight the dual roles of DHA in cellular physiology and pathology. PMID:19023138
Cakmak, Huseyin Altug; Dincgez Cakmak, Burcu; Abide Yayla, Cigdem; Inci Coskun, Ebru; Erturk, Mehmet; Keles, Ibrahim
2017-08-01
The aim of this study was to evaluate the relation of three new inflammatory markers with presence and severity of preeclampsia and to compare the predictive values of all markers for presence of this setting. In this study, a total of 100 consecutive pregnants with a diagnosis of preeclampsia and 40 healthy pregnants between October 2014 and April 2015 were included. Epicardial fat tissue was calculated by two-dimensional transthoracic echocardiography, and pentraxin-3 and neutrophil-to-lymphocyte ratio were measured by using an enzyme-linked immunosorbent assay method and routine blood count analysis, respectively. Epicardial fat thickness (p < 0.001), pentraxin-3 (p < 0.001), and neutrophil-to-lymphocyte ratio (p < 0.001) were found to be significantly increased in the preeclampsia as compared to the healthy pregnants. Furthermore, epicardial fat thickness (p = 0.002), pentraxin-3 (p < 0.001), and neutrophil-to-lymphocyte ratio (p < 0.001) were significantly elevated in the severe preeclampsia compared to mild preeclampsia. In the multivariate analysis, epicardial fat thickness (p = 0.013), pentraxin-3 (p = 0.04), and neutrophil-to-lymphocyte ratio (p < 0.001) were found as significant independent predictors of presence of preeclampsia after adjusting for other risk factors. Epicardial fat thickness, neutrophil-to-lymphocyte ratio, and pentraxin-3 are important markers that provide an additional information beyond that provided by conventional methods in predicting presence and severity of preeclampsia.
Anisotropic bioelectrical impedance determination of subcutaneous fat thickness
NASA Astrophysics Data System (ADS)
Hernández-Becerra, P. A. I.; Delgadillo-Holtfort, I.; Balleza-Ordaz, M.; Huerta-Franco, M. R.; Vargas-Luna, M.
2014-11-01
Preliminary results have shown that bioelectrical impedance measurements performed on different parts of the human body strongly depend upon the subcutaneous fat of the considered region. In this work, a method for the determination of subcutaneous fat thickness is explored. Within this method the measurement of the bioelectrical impedance response of the fat-muscle system, both along the direction defined by the muscle fibers and along the corresponding perpendicular direction, are performed. Measurements have been carried out on human female and male subjects of ages around 25 years old at the region of the biceps. Correlation has been performed with skinfold caliper measurements.
Safety and Efficacy of a Non-Invasive 1060 nm Diode Laser for Fat Reduction of the Abdomen.
Bass, Lawrence S; Doherty, Sean T
2018-01-01
Changes in temperature are known to produce apoptosis in adipocytes. This study examines the use of a non-invasive treatment that applies 1060 nm laser energy transcutaneously to hyperthermically induce disruption of fat cells in the abdomen. Thirty-five subjects received application of 1060 nm laser on the abdomen for fat reduction. Ultrasound images and high-resolution two-dimensional photography were recorded at baseline, 6 weeks, and 12 weeks post treatment. Subjects maintained a stable diet and exercise routine throughout the course of the study. Weight was recorded at baseline and each follow-up visit. Three board certified dermatologists were trained as blinded evaluators and tasked with identifying before and after photographs from randomized, paired baseline, and 12-week photographs. Ultrasound images were used to measure the fat thickness change from baseline at 6 and 12 weeks. Level of patient satisfaction was graded at 12 weeks using a 6 point Likert scale. 23% of subjects were Fitzpatrick IV-VI. Blinded evaluators correctly identified the post-treatment photograph 95% of the time (88%, 97%, and 100%). Mean reduction in fat layer thickness from baseline was statistically significant (P less than 0.001) at both 6 weeks (1.5 +/-1.23 mm) and 12 weeks (2.65 +/-1.41 mm). Mean weight change was +0.1 lb. Side effects were mild to moderate including edema, tenderness, and induration mostly resolving within 1-3 weeks post treatment. No serious adverse events were reported. 1060 nm based laser treatment can consistently reduce the fat contour in the abdomen with an excellent safety profile in all skin types. The study met all three of its prospectively defined endpoints of success.
J Drugs Dermatol. 2018;17(1):106-112.
THIS ARTICLE HAD BEEN MADE AVAILABLE FREE OF CHARGE.
PLEASE SCROLL DOWN TO ACCESS THE FULL TEXT OF THIS ARTICLE WITHOUT LOGGING IN.
NO PURCHASE NECESSARY.
PLEASE CONTACT THE PUBLISHER WITH ANY QUESTIONS.
.The Use of B-Mode Ultrasound for Measuring Subcutaneous Fat Thickness on the Upper Arms.
ERIC Educational Resources Information Center
Weiss, Lawrence W.; Clark, Frank C.
1985-01-01
A study was carried out to investigate the potential use of B-mode ultrasound for measuring subcutaneous fat thickness at two arm sites. B-mode sonograms and skinfold measurements were found to be highly correlated for both men and women. (Author/MT)
Kostopoulos, Konstantinos; Alhanatis, Emmanouil; Pampoukas, Konstantinos; Georgiopoulos, Georgios; Zourla, Andromahi; Panoutsopoulos, Athanasios; Kallianos, Anastasios; Velentza, Lemonia; Zarogoulidis, Paul; Trakada, Georgia
2016-05-01
Obstructive sleep apnea-hypopnea syndrome (OSAHS) is an independent risk factor for hypertension, coronary artery disease, and diabetes mellitus. Epicardial fat has been recently recognized as a new risk factor and active participant on cardiometabolic risk. The aim of this study was to assess an independent relationship between sleep apnea severity, metabolic and vascular markers, and epicardial fat, at baseline and after 3 months of continuous positive airway pressure (CPAP) therapy. Our study group consisted of 48 patients with suspected OSAHS and no prior history of cardiovascular disease or diabetes mellitus. All patients underwent full overnight polysomnography. Thickness of epicardial and visceral adipose tissue, brachial artery flow-mediated dilation (FMD), carotid intima media thickness (cIMT), pulse wave velocity (PWV), plasma C-reactive protein (CRP) levels, fasting glucose levels, HbA1c, homeostatic model assessment of insulin resistance index (HOMA), and lipid profile were measured at baseline and after 3 months of CPAP use in patients with moderate to severe OSAHS. In OSAHS patients (Apnea-hypopnea index (AHI) ≥15/h, N = 28), epicardial fat correlated with fasting glucose (rho = 0.406, p = 0.04) and HOMA (rho = 0.525, p = 0.049) but was not associated with visceral fat (rho = 0.126, p = 0.595). Epicardial adipose tissue (EAT) (p = 0.022) increased across AHI severity along with PWV (p = 0.045) and carotid intima media thickness (IMT) (p = 0.034) while FMD (p = 0.017) decreased. Therapy with CPAP reduced both epicardial (p < 0.001) and visceral fat (p = 0.001). Alterations in epicardial fat across the follow-up were associated with changes in PWV (p = 0.026) and HOMA (p = 0.037) independently of major confounders. Epicardial fat thickness was associated with OSA severity and may be an additional marker of cardiovascular risk as well as of future diabetes in these patients. CPAP therapy reduced epicardial fat, suggesting its potentially beneficial role in reducing cardiometabolic risk in OSA patients.
Evaluating the association of APOA2 polymorphism with insulin resistance in adolescents
Zaki, Moushira Erfan; Amr, Khalda Sayed; Abdel-Hamid, Mohamed
2014-01-01
Background 265T>C SNP in the APOA-II gene promoter may be associated with obesity risk and insulin resistance (IR). This study aims to analyze the association between the APOA2 − 265T>C SNP and risk for obesity and IR in adolescents. Material and methods The study was conducted on 500 adolescents. They were 240 obese and 260 non-obese individuals, aged 16–21 years old. Their mean age was 18.25 ± 2.54 years. Variables examined body weight, height, waist circumference (WC), systolic and diastolic blood pressure (BP), body fat percentage (BF%), and abdominal visceral fat layer. Homeostasis Model Assessment of Insulin Resistance (HOMA-IR) was used as a biomarker for IR. BF% was assessed by body composition analyzer and abdominal visceral fat thickness was determined by ultrasonography. The APOA2 − 265T>C polymorphism genotype was analyzed by PCR amplification of a 273-bp fragment. Results Genotype frequencies were in Hardy–Weinberg equilibrium. The frequency of the mutant C allele was significantly higher in obese cases than non-obese cases. After multivariate adjustment, waist, BF%, visceral adipose layer and HOMA-IR were significantly higher in homozygous allele CC carriers than TT + TC carriers. Homozygous individuals for the CC allele had statistically higher values of energy intake, total fat (g/day) and saturated fat (SATFAT) than carriers of the T allele. Conclusions Homozygous individuals for the C allele had higher obesity risk than carriers of the T allele and had elevated levels of visceral adipose tissue. Moreover, the present study shows that the CC polymorphism is associated with the development of IR [OR 1.89 (1.35–2.91), P = .012] and remains significant after adjusting for gender, age and body mass index. PMID:25606421
Dearborn, Jennifer L.; Qiao, Ye; Guallar, Eliseo; Steffen, Lyn M.; Gottesman, Rebecca F.; Zhang, Yiyi; Wasserman, Bruce A.
2016-01-01
Background and aims Carbohydrates and fat intake have both been linked to development of atherosclerosis. We examined associations between glycemic index GI and fat intake with carotid atherosclerosis. Methods The Atherosclerosis Risk in Communities (ARIC) cohort enrolled participants during the period 1987–1989 and the Carotid MRI sub-study occurred between 2004 and 2006 (1,672 participants attending both visits). Measures of carbohydrate quality (usual GI), fat intake (total, polyunsaturated and saturated) and overall dietary quality index (DASH Diet Score) were derived from a 66-item food frequency questionnaire administered at baseline. Trained readers measured lipid core presence and maximum wall thickness. Using multivariate logistic regression, we determined the odds of lipid core presence by quintile (Q) of energy-adjusted dietary components. Restricted cubic spline models were used to examine non-linear associations between dietary components and maximum wall thickness. Results Mean daily polyunsaturated fat intake was 5 g (SD 1.4). GI and polyunsaturated fat intake had a nonlinear relationship with maximum wall thickness. Low (1–4 g) and high (6–12 g) polyunsaturated fat intake were associated with a statistically significant decreased odds of lipid core presence compared to intake in a majority of participants (OR Q5 vs. Q2–4: 0.64, 95% CI 0.42 to 0.98; OR Q1 vs. Q2–4: 0.64, 95% CI 0.42, 0.96), however, the association with lipid core was attenuated by adjustment for maximum wall thickness, hypertension, hyperlipidemia, and diabetes. Conclusions GI and polyunsaturated fat intake were not associated with high-risk plaque features, such as lipid core presence, independent of traditional vascular risk factors. PMID:27234460
Dearborn, Jennifer L; Qiao, Ye; Guallar, Eliseo; Steffen, Lyn M; Gottesman, Rebecca F; Zhang, Yiyi; Wasserman, Bruce A
2016-08-01
Carbohydrates and fat intake have both been linked to development of atherosclerosis. We examined associations between glycemic index (GI) and fat intake with carotid atherosclerosis. The Atherosclerosis Risk in Communities (ARIC) cohort enrolled participants during the period 1987-1989 and the Carotid MRI sub-study occurred between 2004 and 2006 (1672 participants attending both visits). Measures of carbohydrate quality (usual GI), fat intake (total, polyunsaturated and saturated) and overall dietary quality index (DASH Diet Score) were derived from a 66-item food frequency questionnaire administered at baseline. Trained readers measured lipid core presence and maximum wall thickness. Using multivariate logistic regression, we determined the odds of lipid core presence by quintile (Q) of energy-adjusted dietary components. Restricted cubic spline models were used to examine non-linear associations between dietary components and maximum wall thickness. Mean daily polyunsaturated fat intake was 5 g (SD 1.4). GI and polyunsaturated fat intake had a nonlinear relationship with maximum wall thickness. Low (1-4 g) and high (6-12 g) polyunsaturated fat intake were associated with a statistically significant decreased odds of lipid core presence compared to intake in a majority of participants (OR Q5 vs. Q2-4: 0.64, 95% CI 0.42 to 0.98; OR Q1 vs. Q2-4: 0.64, 95% CI 0.42, 0.96), however, the association with lipid core was attenuated by adjustment for maximum wall thickness, hypertension, hyperlipidemia, and diabetes. GI and polyunsaturated fat intake were not associated with high-risk plaque features, such as lipid core presence, independent of traditional vascular risk factors. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Freedman, David S; Ogden, Cynthia L; Kit, Brian K
2015-11-18
Although the estimation of body fatness by Slaughter skinfold thickness equations (PBF(Slaughter)) has been widely used, the accuracy of this method is uncertain. We have previously examined the interrelationships among the body mass index (BMI), PBF(Slaughter), percent body fat from dual energy X-ray absorptiometry (PBF(DXA)) and CVD risk factor levels among children who were examined in the Bogalusa Heart Study and in the Pediatric Rosetta Body Composition Project. The current analyses examine these associations among 7599 8- to 19-year-olds who participated in the (U.S.) National Health and Nutrition Examination Survey from 1999 to 2004. We analyzed (1) the agreement between (1) estimates of percent body fat calculated from the Slaughter skinfold thickness equations and from DXA, and (2) the relation of lipid, lipoprotein, and blood pressure levels to BMI, PBF(Slaughter) and PBF(DXA). PBF(Slaughter) was highly correlated (r ~ 0.85) with PBF(DXA). However, among children with a relatively low skinfold thicknesses sum (triceps + subscapular), PBF(Slaughter) underestimated PBF(DXA) by 8 to 9 percentage points. In contrast, PBF(Slaughter) overestimated PBF(DXA) by 10 points among boys with a skinfold thickness sum ≥ 50 mm. After adjustment for sex and age, lipid levels were related similarly to the body mass index, PBF(DXA) and PBF(Slaughter). There were, however, small differences in associations with blood pressure levels: systolic blood pressure was more strongly associated with body mass index, but diastolic blood pressure was more strongly associated with percent body fat. The Slaughter equations yield biased estimates of body fatness. In general, lipid and blood pressure levels are related similarly to levels of BMI (following adjustment for sex and age), PBF(Slaughter,) and PBF(DXA).
Health technology assessment of non-invasive interventions for weight loss and body shape in Iran
Nojomi, Marzieh; Moradi-Lakeh, Maziar; Velayati, Ashraf; Naghibzadeh-Tahami, Ahmad; Dadgostar, Haleh; Ghorabi, Gholamhossein; Moradi-Joo, Mohammad; Yaghoubi, Mohsen
2016-01-01
Background: The burden of obesity and diet-related chronic diseases is increasing in Iran, and prevention and treatment strategies are needed to address this problem. The aim of this study was to determine the outcome, cost, safety and cost-consequence of non-invasive weight loss interventions in Iran. Methods: We performed a systematic review to compare non-invasive interventions (cryolipolysis and radiofrequency/ ultrasonic cavitation) with semi-invasive (lipolysis) and invasive (liposuction). A sensitive electronic searching was done to find available interventional studies. Reduction of abdomen circumference (cm), reduction in fat layer thickness (%) and weight reduction (kg) were outcomes of efficacy. Meta-analysis with random models was used for pooling efficacy estimates among studies with the same follow-up duration. Average cost per intervention was estimated based on the capital, maintenance, staff, consumable and purchase costs. Results: Of 3,111 studies identified in our reviews, 13 studies assessed lipolysis, 10 cryolipolysis and 8 considered radiofrequency. Nine studies with the same follow-up duration in three different outcome group were included in meta-analysis. Radiofrequency showed an overall pooled estimate of 2.7 cm (95% CI; 2.3-3.1) of mean reduction in circumference of abdomen after intervention. Pooled estimate of reduction in fat layer thickness was 78% (95% CI; 73%-83%) after Lipolysis and a pooled estimate of weight loss was 3.01 kg (95% CI; 2.3-3.6) after lipousuction. The cost analysis revealed no significant differences between the costs of these interventions. Conclusion: The present study showed that non-invasive interventions appear to have better clinical efficacy, specifically in the body shape measurement, and less cost compared to invasive intervention (liposuction) PMID:27390717
Zhao, Jing; Wang, Ya Xing; Zhang, Qi; Wei, Wen Bin; Xu, Liang; Jonas, Jost B
2018-03-13
To study macular choroidal layer thickness, 3187 study participants from the population-based Beijing Eye Study underwent spectral-domain optical coherence tomography with enhanced depth imaging for thickness measurements of the macular small-vessel layer, including the choriocapillaris, medium-sized choroidal vessel layer (Sattler's layer) and large choroidal vessel layer (Haller's layer). In multivariate analysis, greater thickness of all three choroidal layers was associated (all P < 0.05) with higher prevalence of age-related macular degeneration (AMD) (except for geographic atrophy), while it was not significantly (all P > 0.05) associated with the prevalence of open-angle glaucoma or diabetic retinopathy. There was a tendency (0.07 > P > 0.02) toward thinner choroidal layers in chronic angle-closure glaucoma. The ratio of small-vessel layer thickness to total choroidal thickness increased (P < 0.001; multivariate analysis) with older age and longer axial length, while the ratios of Sattler's layer and Haller's layer thickness to total choroidal thickness decreased. A higher ratio of small-vessel layer thickness to total choroidal thickness was significantly associated with a lower prevalence of AMD (early type, intermediate type, late geographic type). Axial elongation-associated and aging-associated choroidal thinning affected Haller's and Sattler's layers more markedly than the small-vessel layer. Non-exudative and exudative AMD, except for geographic atrophy, was associated with slightly increased choroidal thickness.
Gossen, N; Fietze, S; Mösenfechtel, S; Hoedemaker, M
2006-05-01
It was the aim of this study to compare body condition scoring with ultrasonographic back fat thickness. Additionally, the relationship between back fat thickness and fertility, milk yield, number of parity and stage of lactation in dairy cows was examined. Body condition of 211 cows (German Black Pied/HF) was determined by means of ultrasonographic back fat thickness (BFT) and body condition scoring (BCS). The BFT and the BCS were measured at four different stages during the course of lactation (Time point 1 (T1) = 1.-3. d postpartum (pp); T2 = 40.-42. d pp; T3 = 90.-92. d pp and T4 = 130.-150. d pp). Number of parity, 100-day-milk-yield, incidence of ovarian cysts, incidence of acyclicity and fertility measures were recorded. There was a significant correlation between body condition scoring and ultrasonographic measurement of back fat thickness at the four time points (r = 0.68 to 0.74). Therefore, both methods were suitable to evaluate body condition. The number of lactations had an influence on body condition. At T1, the BFT in older cows was significantly higher than in younger cows (P < 0.05). At T3, the BFT in younger cows was higher than in older cows (P < 0.05). With regards to the stage of lactation, there was a significant decrease in body condition from T1 to T2 and T3. At T4, body condition increased, but did not reach the level of the postcalving values. In addition, cows with a high BFT at the beginning of lactation had a higher milk yield and a higher loss of body fat than cows with lower milk yield. Heifers compensated this loss of body fat significantly faster than older cows. Particularly at T3, body condition had an impact on fertility. Cows with a high loss of body condition between T1 and T3 developed significantly more often ovarian cysts than cows with low loss of back fat thickness. Cows with the lowest BFT at T3 had the longest calving to first service intervall and the highest 200-day-non-pregnancy index. In conclusion, our results suggest that there might be a certain relationship between body condition and fertility (delayed first service, ovarian disorders, reduced pregnancy results).
Larkin, Theresa A; Ashcroft, Elfriede; Hickey, Blake A; Elgellaie, Asmahan
2018-01-01
This study aimed to determine the influences of gender, BMI and observed body shape on subcutaneous fat and muscle thicknesses, and theoretical injection outcome, at the ventrogluteal and dorsogluteal intramuscular injection sites. Debate continues as to whether the dorsogluteal or ventrogluteal injection site is more reliable for a successful intramuscular injection outcome. Subcutaneous fat and muscle thicknesses at the injection site are direct determinants of intramuscular injection outcome. BMI and observed body shape influence gluteal subcutaneous fat and muscle thicknesses, and therefore injection outcome, with potentially distinct effects at the ventrogluteal and dorsogluteal sites. This was a cross-sectional study. Demographic data were collected, and subcutaneous fat and muscle thicknesses were quantified bilaterally at the dorsogluteal and ventrogluteal injection sites using ultrasound, for 145 participants (57% female). Subcutaneous fat and muscle were significantly thicker at the dorsogluteal than the ventrogluteal site, and 75% and 86% of participants would receive a successful intramuscular injection at these sites, respectively. There were significant effects of gender, BMI and observed body shape on subcutaneous fat thickness and theoretical injection outcome at both sites. Females, obese individuals and endomorph individuals had thicker subcutaneous fat and were more likely to have a subcutaneous injection outcome. Gender, BMI and observed body shape could be used to guide site and needle length selection when administering gluteal intramuscular injections to increase the likelihood of a successful intramuscular injection outcome. Both gluteal injection sites should be avoided in obese individuals and endomorph individuals. An intramuscular injection will be successful: using a 32-mm needle at the ventrogluteal site for all males and normal-weight females and using a 38-mm needle for all females at the ventrogluteal site, and for all males and at least 98% of females at the dorsogluteal site. © 2017 John Wiley & Sons Ltd.
The Use of Skinfold to Estimate Body Fatness on Children and Youth.
ERIC Educational Resources Information Center
Lohman, T. G.
1987-01-01
Concern about the body fat of children and its relation to adult obesity has led to the development of standards for assessing children's optimal body fat content. The use of skinfold thickness measures to establish the degree of fatness is described. (MT)
Chan, Victoria O; McDermott, Shaunagh; Buckley, Orla; Allen, Sonya; Casey, Michael; O'Laoide, Risteard; Torreggiani, William C
2012-11-01
To determine the relationship of increasing body mass index (BMI) and abdominal fat on the effective dose acquired from computed tomography (CT) abdomen and pelvis scans. Over 6 months, dose-length product and total milliamp-seconds (mAs) from routine CT abdomen and pelvis scans of 100 patients were recorded. The scans were performed on a 64-slice CT scanner by using an automatic exposure control system. Effective dose (mSv) based on dose-length product, BMI, periumbilical fat thickness, and intra-abdominal fat were documented for each patient. BMI, periumbilical fat thickness, and intra-abdominal fat were compared with effective dose. Thirty-nine men and 61 women were included in the study (mean age, 56.3 years). The mean BMI was 26.2 kg/m(2). The mean effective dose was 10.3 mSv. The mean periumbilical fat thickness was 2.4 cm. Sixty-five patients had a small amount of intra-abdominal fat, and 35 had a large amount of intra-abdominal fat. The effective dose increased with increasing BMI (P < .001) and increasing amounts of intra-abdominal fat (P < .001). For every kilogram of weight, there is a 0.13 mSv increase in effective dose, which is equal to 6.5 chest radiographs per CT examination. For an increase in BMI by 5 kg/m(2), there is a 1.95 mSv increase in effective dose, which is equal to 97.5 chest radiographs per CT examination. Increasing BMI and abdominal fat significantly increases the effective dose received from CT abdomen and pelvis scans. Copyright © 2012 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
Larkin, Theresa A; Ashcroft, Elfriede; Elgellaie, Asmahan; Hickey, Blake A
2017-06-01
The dorsogluteal and ventrogluteal intramuscular injection sites both have their use in clinical practice; however, it has not been established in whom one or the other should be preferentially targeted or avoided. There is a need for an evidence-based approach towards site selection for a successful intramuscular injection outcome and to avoid unwanted injection outcomes of inadvertent subcutaneous injection or bone contact. Injection outcome is dependent on injection site subcutaneous fat thickness and muscle thickness; these are likely influenced by gender and anthropometry. To determine whether subcutaneous fat, muscle, and total tissue thicknesses differ between the dorsogluteal and ventrogluteal sites, and whether theoretical injection outcome (intramuscular, subcutaneous, or bone contact) can be predicted by demographic and anthropometric data and described by an algorithm. Cross-sectional study design. University in Australia. 145 volunteers (57% female) of at least 18 years of age recruited through the university community. Anthropometric data was collected and subcutaneous fat and muscle thicknesses were quantified by ultrasonography. Anthropometric differences between theoretical injection outcome groups (bone contact versus intramuscular versus subcutaneous at the ventrogluteal and dorsogluteal sites) was determined for each gender (ANOVA). Multiple regression analysis was conducted to determine the influence of demographic and anthropometric data on theoretical intramuscular injection outcome. An algorithm to guide site selection was developed for each gender, based on the anthropometric measures that best discriminated between injection outcomes. Subcutaneous fat, muscle and total tissue were significantly thicker at the dorsogluteal site than the ventrogluteal site, and subcutaneous fat was significantly thicker in females than males at both sites (all p<0.001); there was no gender difference for muscle or total tissue thickness at either site. Female gender, and waist and hip circumference were significant predictors of subcutaneous fat thickness at both sites; male gender was a significant predictor of dorsogluteal site muscle thickness (all p<0.05). In the algorithm developed for site selection based on theoretical injection outcome, the best discriminators were: weight, BMI and waist circumference for females, and weight and distance between the iliac tubercle and anterior superior iliac spine for males. The algorithm describes when each of the ventrogluteal and dorsogluteal sites is appropriate or should be avoided, based on easily obtained anthropometric data. This has direct relevance in clinical practice in evidence-based site selection for gluteal intramuscular injections for optimal medication and health outcomes. Copyright © 2017 Elsevier Ltd. All rights reserved.
Zhang, Lianshan; Liang, Libin; Tong, Tong; Qin, Yuguo; Xu, Yanping; Tong, Xinglong
2016-10-01
Context Recently, adenosine triphosphate (ATP) was occasionally found to decrease the triglyceride (TG) levels in several hyperlipidemic patients in our clinical practice. Objective The study investigates the anti-hyperlipidemic effects of ATP in a high-fat fed rabbit model and hyperlipidemic patients. Materials and methods Twenty-four rabbits were randomly divided into three groups of eight animals each as follows: normal diet, high-fat diet and high-fat diet + ATP group. ATP supplementation (40 mg/day) was started at the 20th day and lasted for 10 days. Serum concentrations of total cholesterol (TC), TG, LDL-C, HDL-C were measured on the 20th day and 30th day. Heart, liver and aorta were subjected histopathological examination. Twenty outpatients diagnosed primary hyperlipidemia took ATP at a dose of 60 mg twice a day for 1 week. Results Feeding rabbits with a high-fat diet resulted in a significant elevation of lipid parameters including TC, TG, LDL-C, VLDL-C compared to the normal diet group (p < 0.01). ATP treatment significantly decreased serum TG level (p < 0.01), whilst other parameters remained statistically unaltered. Meanwhile, ATP significantly reduced the thickness of fat layer in cardiac epicardium (p < 0.05) and pathological gradation of ballooning degeneration in hepatocytes (p < 0.05). After taking ATP for 1 week, hyperlipidemia patients exhibited a significant decrease of TG (p < 0.01), but other lipid parameters had no significant change. Discussion and conclusion The study indicates that ATP selectively decreases serum TG levels in high-fat diet rabbits and hyperlipidemic patients. Therefore, ATP supplementation may provide an effective approach to control TG level.
Ceacero, Thais Matos; Mercadante, Maria Eugênia Zerlotti; Cyrillo, Joslaine Noely Dos Santos Gonçalves; Canesin, Roberta Carrilho; Bonilha, Sarah Figueiredo Martins; de Albuquerque, Lucia Galvão
2016-01-01
This study evaluated phenotypic (rph) and genetic correlations (rg) between 8 feed efficiency traits and other traits of economic interest including weight at selection (WS), loin-eye area (LEA), backfat thickness (BF), and rump fat thickness (RF) in Nellore cattle. Feed efficiency traits were gain:feed, residual feed intake (RFI), residual feed intake adjusted for backfat thickness (RFIb) and for backfat and rump fat thickness (RFIsf), residual body weight gain (RG), residual intake and body weight gain (RIG), and residual intake and body weight gain using RFIb (RIGb) and RFIsf (RIGsf). The variance components were estimated by the restricted maximum likelihood method using a two-trait animal model. The heritability estimates (h2) were 0.14, 0.24, 0.20, 0.22, 0.19, 0.15, 0.11 and 0.11 for gain:feed, RFI, RFIb, RFIsf, RG, RIG, RIGb and RIGsf, respectively. All rph values between traits were close to zero, except for the correlation of feed efficiency traits with dry matter intake and average daily gain. High rg values were observed for the correlation of dry matter intake, average daily gain and metabolic weight with WS and hip height (>0.61) and low to medium values (0.15 to 0.48) with the carcass traits (LEA, BF, RF). Among the feed efficiency traits, RG showed the highest rg with WS and hip height (0.34 and 0.25) and the lowest rg with subcutaneous fat thickness (-0.17 to 0.18). The rg values of RFI, RFIb and RFIsf with WS (0.17, 0.23 and 0.22), BF (0.37, 0.33 and 0.33) and RF (0.30, 0.31 and 0.32) were unfavorable. The rg values of gain:feed, RIG, RIGb and RIGsf with WS were low and favorable (0.07 to 0.22), while medium and unfavorable (-0.22 to -0.45) correlations were observed with fat thickness. The inclusion of subcutaneous fat thickness in the models used to calculate RFI did not reduce the rg between these traits. Selecting animals for higher feed efficiency will result in little or no genetic change in growth and will decrease subcutaneous fat thickness in the carcass.
Ng, Susanna S S; Liu, Eric K H; Ma, Ronald C W; Chan, Tat-On; To, Kin-Wang; Chan, Ken K P; Ngai, Jenny; Yip, Wing-Ho; Ko, Fanny W S; Wong, Chun-Kwok; Hui, David S C
2017-05-01
Obstructive sleep apnoea (OSA) is associated with an increased prevalence of metabolic syndrome. This study explores the effects of continuous positive airway pressure (CPAP) for patients with OSA on visceral and mesenteric fat thickness, carotid intima-media thickness (IMT) and adipokines. A randomized controlled study was conducted at a teaching hospital on 90 patients newly diagnosed with OSA to receive either therapeutic CPAP or subtherapeutic CPAP for 3 months. Visceral fat thickness and carotid IMT were measured with B-mode ultrasound; adipokine levels were assessed at baseline and 3 months. Altogether, 45 patients received therapeutic CPAP and 45 received subtherapeutic CPAP without significant differences in age 50.3 (10.1) versus 48.7 (9.0) years, BMI 28.2 (3.9) versus 28.2 (4.5) kg/m 2 , Epworth Sleepiness Scale (ESS) 12.4 (5.9) versus 11.3 (4.7), apnoea-hypopnoea index (AHI) 30.6 (21.4) versus 35.2 (25.5) /h, minimum SaO 2 79.6 (10.8) versus 76.7 (12.4) % and existing co-morbidities. CPAP usage was therapeutic 4.2 (2.1) versus subtherapeutic 4.1 (2.0) h/night over 3 months. Adiponectin and irisin levels changed significantly following therapeutic CPAP for 3 months versus subtherapeutic CPAP (-1.6 vs 7.3, P = 0.042; 0.1 vs -0.1, P = 0.028 respectively) while only serum level of monocyte chemotactic protein 1 (MCP-1) at baseline was positively correlated with AHI (r = 0.278). No significant changes were observed in other adipokines, visceral fat thickness and IMT. Short-term therapeutic CPAP versus subtherapeutic CPAP does not significantly reduce visceral fat thickness and IMT, although it reduces adiponectin and increases irisin. © 2016 Asian Pacific Society of Respirology.
Sakamoto, L S; Mercadante, M E Z; Bonilha, S F M; Branco, R H; Bonilha, E F M; Magnani, E
2014-11-01
Data from 156 Nellore males were used to develop equations for the prediction of retail beef yield and carcass fat content, expressed as kilograms and as a percentage, from live animal and carcass measurements. Longissimus muscle area and backfat and rump fat thickness were measured by ultrasound up to 5 d before slaughter and fasted live weight was determined 1 d before slaughter. The same traits were obtained after slaughter. The carcass edible portion (CEP in kg and CEP% in percentage; n = 116) was calculated by the sum of the edible portions of primal cuts: hindquarter, forequarter, and spare ribs. Trimmable fat from the carcass boning process, with the standardization of about 3 mm of fat on retail beef, was considered to be representative of carcass fat content. Most of the variation in CEP was explained by fasted live weight or carcass weight (R(2) of 0.92 and 0.96); the same occurred for CEP% (R(2) of 0.15 and 0.13), and for CEP, the inclusion of LM area and fat thickness reduced the equation bias (lower value of Mallow's Cp statistics). For trimmable fat, most variation could be explained by weight or rump fat thickness. In general, the equations developed from live animal measurements showed a predictive power similar to the equations using carcass measurements. In all cases, the traits expressed as kilograms were better predicted (R(2) of 0.39 to 0.96) than traits expressed as a percentage (R(2) of 0.08 to 0.42).
Mechanical modeling and characteristic study for the adhesive contact of elastic layered media
NASA Astrophysics Data System (ADS)
Zhang, Yuyan; Wang, Xiaoli; Tu, Qiaoan; Sun, Jianjun; Ma, Chenbo
2017-11-01
This paper investigates the adhesive contact between a smooth rigid sphere and a smooth elastic layered medium with different layer thicknesses, layer-to-substrate elastic modulus ratios and adhesion energy ratios. A numerical model is established by combining elastic responses of the contact system and an equation of equivalent adhesive contact pressure which is derived based on the Hamaker summation method and the Lennard-Jones intermolecular potential law. Simulation results for hard layer cases demonstrate that variation trends of the pull-off force with the layer thickness and elastic modulus ratio are complex. On one hand, when the elastic modulus ratio increases, the pull-off force decreases at smaller layer thicknesses, decreases at first and then increases at middle layer thicknesses, while increases monotonously at larger layer thicknesses. On the other hand, the pull-off force decreases at first and then increases with the increase in the layer thickness. Furthermore, a critical layer thickness above which the introduction of hard layer cannot reduce adhesion and an optimum layer thickness under which the pull-off force reaches a minimum are found. Both the critical and optimum layer thicknesses become larger with an increase in the Tabor parameter, while they tend to decrease with the increase in the elastic modulus ratio. In addition, the pull-off force increases sublinearly with the adhesion energy ratio if the layer thickness and elastic modulus ratio are fixed.
Sourwine, Mariaileen; Jeudy, Jean; Miller, Brian; Vunnam, Rama; Imanli, Hasan; Mesubi, Olurotimi; Etienne-Mesubi, Martine; See, Vincent; Shorofsky, Stephen; Dickfeld, Timm
2017-10-01
A significant number of ventricular tachycardia circuits are located close to the epicardial surface and are amendable to epicardial ablation. Epicardial fat often interferes with substrate mapping and ablation, though little is known regarding the distribution of fat and its fluctuation with the cardiac cycle. We studied 40 patients who underwent a 64-slice multidetector computed tomography in order to describe patterns of epicardial fat distribution, variation during cardiac cycle, and clinical predictors of epicardial fat. Multiplanar reconstructions were analyzed during systole and diastole in six cross-sections. Epicardial fat thickness was measured across multiple wall segments in each view. Epicardial fat was found to be thicker in areas overlying coronary vasculature (7.8 ± 2.6 mm vs 3.5 ± 0.9 mm, P = 0.001), along with the right ventricular wall (3.9 ± 0.8 mm vs 2.6 ± 0.6 mm, P = 0.001) and the ventricular base (6.1 ± 1.7 mm vs 4.6 ± 1.6 mm, P < 0.01). Epicardial fat thickness increased 27% during systole as compared to diastole (4.9 ± 2.7 mm vs 6.2 ± 3.0 mm, P = 0.04). Variation with cardiac cycle was most evident along the right ventricular wall (3.9 ± 0.8 mm vs 5.0 ± 1.3 mm, P = 0.001) and nonvascular areas (P = 0.001), especially at the ventricular base (3.7 ± 1.1 mm vs 5.3 ± 1.5 mm, P = 0.001). In multivariate logistic regression, we found that age >50 years (P = 0.031) and coronary artery disease (P = 0.023) were statistically correlated with epicardial fat >5-mm thickness and body mass index > 33 (P = 0.052) nearly so. Baseline epicardial fat thickness >5 mm is common in areas typically targeted during epicardial ablation and further increases during the cardiac cycle. Simple clinical characteristics can identify patients with >5 mm epicardial fat in which preprocedural computed tomography imaging and three-dimensional fat map reconstruction may facilitate epicardial ablation. © 2017 Wiley Periodicals, Inc.
Putzer, David; Haselbacher, Matthias; Hörmann, Romed; Klima, Günter; Nogler, Michael
2017-12-01
Surgical approaches through smaller incisions reveal less of the underlying anatomy, and therefore, detailed knowledge of the local anatomy and its variations is important in minimally invasive surgery. The aim of this study was to determine the location, extension, and histomorphology of the deep layer of the iliotibial band during minimally invasive hip surgery using the direct anterior approach (DAA). The morphology of the iliotibial tract was determined in this cadaver study on 40 hips with reference to the anterior superior iliac spine and the tibia. The deep layer of the tractus iliotibialis was exposed up to the hip-joint capsule and length and width measurements taken. Sections of the profound iliotibial tract were removed from the hips and the thickness of the sections was determined microscopically after staining. The superficial tractus iliotibialis had a length of 50.1 (SD 3.8) cm, while tensor fasciae latae total length was 18 (SD 2) cm [unattached 15 (SD 2.5) cm]. Length and width of the deep layer of the tractus iliotibialis were 10.4 (SD 1.3) × 3.3 (SD 0.6) cm. The deep iliotibial band always extended from the distal part of the tensor fascia latae (TFL) muscle to the lateral part of the hip capsule (mean maximum thickness 584 μm). Tractus iliotibialis deep layer morphology did not correlate to other measurements taken (body length, thigh length, and TFL length). The length of the deep layer is dependent on the TFL, since the profound part of the iliotibial band reaches from the TFL to the hip-joint capsule. The deep layer covers the hip-joint capsule, rectus, and lateral vastus muscles in the DAA interval. To access the precapsular fat pad and the hip-joint capsule, the deep layer has to be split in all approaches that use the direct anterior interval.
The suborbicularis oculi fat (SOOF) and the fascial planes: has everything already been explained?
Andretto Amodeo, Chiara; Casasco, Andrea; Icaro Cornaglia, Antonia; Kang, Robert; Keller, Gregory S
2014-01-01
During anatomic and surgical dissections, a connection was seen between the superficial layer of the deep temporal fascia and the prezygomatic area. These findings were in contrast to previous evaluations. This study defines this connection, which is important to understand from both surgical and anatomic standpoints. To define the connection between the superficial layer of the deep temporal fascia and the prezygomatic area and demonstrate the presence of a deep fascial layer in the midface. Anatomical study performed at the Laboratoire d'Anatomie de la Faculté de Médecine de Nice, Sophia Antipolis, France; at the Centre du Don des Corps de l'Université Paris Descartes, Paris, France; and at the Department of Experimental Medicine, Histology, and Embryology Unit of the University of Pavia, Pavia, Italy. Twenty-four hemifaces of 14 white cadavers were dissected to define the relationship between deep temporal fascia and the midface. Four biopsy samples were harvested for histologic analysis. Dissection of 24 hemifaces from the fresh cadavers revealed the following findings. There is a connection of the deep fascia of the temple (superficial layer of deep temporal fascia) to the midface that divides the fat deep to the orbicularis muscle into 2 layers. One layer of fat is the so-called suborbicularis oculi fat (SOOF), which is superficial to the deep fascia, and the other layer of fat (preperiosteal) is deep to the deep fascia and adherent to malar bone. These findings are in contrast to previous anatomical findings. RESULTS In 12 hemifaces, the superficial layer of the deep temporal fascia directly reached the prezygomatic area as a continuous fascial layer. In 16 hemifaces, the superficial sheet of the deep temporal fascia inserted at the level of the zygomatic and lateral orbital rim and continued as a deep fascial layer over the prezygomatic area. In all specimens, a deep fascial layer was present in the prezygomatic-infraorbital area. This deep fascial layer is adherent to the muscles of the infraorbital area, and it divided the fat located deep to the orbicularis oculi muscle into 2 layers: the SOOF and a deeper layer. Histologic examination of the biopsy samples confirmed these findings. This study demonstrates the existence of a deep fascial layer in the midface. This fascia is connected to the superficial layer of the deep temporal fascia, and it divides the fat deep to the orbicularis oculi muscle into 2 layers. This new finding carries interesting implications related to the classic concept of the superficial musculoaponeurotic system. NA.
Bayarri, S; Carbonell, I; Costell, E
2012-12-01
The effect of the 2 common consumption temperatures, refrigeration temperature (10°C) and room temperature (22°C), on the viscoelasticity, mechanical properties, and perceived texture of commercial cream cheeses was studied. Two samples with different fat contents, regular and low fat, from each of 4 selected commercial brands were analyzed. The selection criteria were based on identification of brands with different percentages of fat content reduction between the regular- and low-fat samples (35, 50, 84, and 98.5%). The fat content of regular-fat samples ranged from 19.8 to 26.0% (wt/wt), and that of low-fat samples ranged from 0.3 to 13.0% (wt/wt). Viscoelasticity was measured in a controlled-stress rheometer using parallel-plate geometry, and the mechanical characteristics of samples were measured using the spreadability test. Differences in the intensity of thickness, creaminess, and roughness between the regular- and low-fat samples of each commercial brand were evaluated at each of the selected temperatures by using the paired comparisons test. At 10°C, all samples showed higher viscoelastic modulus values, firmness, and stickiness, and lower spreadability than when they were measured at 22°C. Differences in viscoelasticity and mechanical properties between each pair of samples of the same brand were greater at 10°C than at 22°C because of the influence not only of fat content but also of fat state. Ingestion temperature did not modify the sensory differences detected between each pair of samples in terms of creaminess and roughness, but it did modify the differences detected in thickness. The joint consideration of sample composition, fat state, and product behavior during oral processing could explain the differences detected in thickness perceived because of measurement temperatures. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
On the use of The Bio-Impedance technique for Body Composition Measurements
NASA Astrophysics Data System (ADS)
Huerta-Franco, R.; Vargas-Luna, M.; González-Solís, J. L.; Gutiérrez-Juárez, G.
2003-09-01
Reviewing the methods and physical principles used in body composition measurements (BCM), it is evident that more accurate, reliable, and easily handled methods are required. The use of bio-impedance analysis (BIA) has been very useful in BCM. This technique, in the single frequency mode, has some commercial versions to perform BCM. However these apparatus have significant variability in the BCM values. The multi-frequency option of the bio-impedance technique has still a lot of challenges to overcome. We studied the variability of the body impedance spectrum (from 1 Hz to 1 MHz) in a group of subjects compared to the values obtained from commercial apparatus. We compared different anatomical body regions, some of them with less subcutaneous body fat (frontal, anterior tibial, knee, and frontal regions); others with more subcutaneous body fat (pectoral, abdominal, and internal calf regions). In order to model the bio-impedance spectrum, we analyzed layered samples with different thickness and material composition.
Analysis of the factors creating consumer attributes of roasted beef steaks.
Guzek, Dominika; Głąbska, Dominika; Gutkowska, Krystyna; Wierzbicki, Jerzy; Woźniak, Alicja; Wierzbicka, Agnieszka
2015-03-01
The aim of the study was to analyze the factors creating consumer attributes of roasted beef steaks of various animals. Eight cuts from 30 carcasses (characterized by various types of animal, conformation and fat class, rib fat thickness, ossification score) were selected. Samples were prepared using the roasting method and consumers rated the tenderness, juiciness, flavor, overall acceptability (rated in a 100-point scale), and satisfaction (rated from 2 to 5) for analyzed samples. No influence of type of animal, fat class, conformation class or ossification score on the results of consumer analysis was observed. For all analyzed factors, the influence of cut on consumer analysis was observed (the highest values of all consumer attributes were observed for tenderloin - for juiciness significantly higher than for other cuts, for tenderness, flavor and MQ4 comparable only with rump (RMP231), while for overall acceptability and satisfaction - with both rump cuts). For rib fat thickness consumer attributes of roasted beef meat were not linear, but the influence was observed - the highest values of consumer attributes were observed for 13 mm rib fat thickness. © 2014 Japanese Society of Animal Science.
[The role of epicardial fat and obesity parameters in the prediction of coronary heart disease].
Prídavková, Dana; Kantárová, Daniela; Lišková, Renáta; Červeň, Peter; Kovář, František; Mokáň, Marián
2016-04-01
To assess the relationship of parameters of obesity in relationship to coronary angiography findings with correlation of epicardial fat (EF) thickness in uppermentioned context. There were 80 patients examined (43 males, 37 postmenopausal females) undergoing elective coronary angiography. We examined the regular obesity parameters - BMI, waist circumference (WC), neck circumference (NC), total body fat (TBF), and visceral fat (VF) using bioimpedance. We assessed the echocardiographically measured EF thickness. We added examination of lipidogram, glycaemia, HOMA-IR (insulin resistance index) and AIP (aterogenic index of plasma). The set was divided into group with coronarographically proved stenosis or stenoses (withCS), and a group without finding of quantifiable stenosis or stenoses (withoutCS). The average thickness of EF in withCS group was 6.3 vs 5.6 mm in group withoutCS (p < 0.025). The differences in the thickness of EF in mentioned groups were 6.5 vs 5.2 mm in males (p < 0.025, = 20 %) and 6.1 vs 6.0 mm in females (p < 0.025, = 1.64 %). In males in withCS group, there was a dominant fat increase in epicardial region and TBF, and in females in withCS group, the fat deposits were increased in general. BMI was not a dominant parameter of adiposity in neither group (males in withCS group 31.11 vs withoutCS 30.41 kg/m(2); females in withCS group 31.40 vs withoutCS 31.20 kg/m(2)). EF was correlated the most by WC in males (r = 0.488; p < 0.005), and in females too (r = 0.564, p < 0.005). The patients in withCS group had increased HOMA-IR 4.75 vs 3.56 in withoutCS group, and AIP 0.22 vs 0.17. Thickness of EF in males and VT in females could be considered obesity parameters in assessment of pre-clinical stages of coronary atherosclerosis and prediction of risk of coronary heart disease. In adipose parameters, EF thickness was correlated the most by WC. Risk stratification of coronary artery disease is supplemented by increased HOMA-IR and AIP.
Johnston, J L; Leong, M S; Checkland, E G; Zuberbuhler, P C; Conger, P R; Quinney, H A
1988-12-01
Body density and skinfold thickness at four sites were measured in 140 normal boys, 168 normal girls, and 6 boys and 7 girls with cystic fibrosis, all aged 8-14 y. Prediction equations for the normal boys and girls for the estimation of body-fat content from skinfold measurements were derived from linear regression of body density vs the log of the sum of the skinfold thickness. The relationship between body density and the log of the sum of the skinfold measurements differed from normal for the boys and girls with cystic fibrosis because of their high body density even though their large residual volume was corrected for. However the sum of skinfold measurements in the children with cystic fibrosis did not differ from normal. Thus body fat percent of these children with cystic fibrosis was underestimated when calculated from body density and invalid when calculated from skinfold thickness.
Nieves-Moreno, María; Martínez-de-la-Casa, José M; Morales-Fernández, Laura; Sánchez-Jean, Rubén; Sáenz-Francés, Federico; García-Feijoó, Julián
2018-01-01
To examine differences in individual retinal layer thicknesses measured by spectral domain optical coherence tomography (SD-OCT) (Spectralis®) produced with age and according to sex. Cross-sectional, observational study. The study was conducted in 297 eyes of 297 healthy subjects aged 18 to 87 years. In one randomly selected eye of each participant the volume and mean thicknesses of the different macular layers were measured by SD-OCT using the instrument's macular segmentation software. Volume and mean thickness of macular retinal nerve fiber layer (mRNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL), retinal pigmentary epithelium (RPE) and photoreceptor layer (PR). Retinal thickness was reduced by 0.24 μm for every one year of age. Age adjusted linear regression analysis revealed mean GCL, IPL, ONL and PR thickness reductions and a mean OPL thickness increase with age. Women had significantly lower mean GCL, IPL, INL, ONL and PR thicknesses and volumes and a significantly greater mRNFL volume than men. The thickness of most retinal layers varies both with age and according to sex. Longitudinal studies are needed to determine the rate of layer thinning produced with age.
Ariyasu, Aoi; Hattori, Yusuke; Otsuka, Makoto
2017-06-15
The coating layer thickness of enteric-coated tablets is a key factor that determines the drug dissolution rate from the tablet. Near-infrared spectroscopy (NIRS) enables non-destructive and quick measurement of the coating layer thickness, and thus allows the investigation of the relation between enteric coating layer thickness and drug dissolution rate. Two marketed products of aspirin enteric-coated tablets were used in this study, and the correlation between the predicted coating layer thickness and the obtained drug dissolution rate was investigated. Our results showed correlation for one product; the drug dissolution rate decreased with the increase in enteric coating layer thickness, whereas, there was no correlation for the other product. Additional examination of the distribution of coating layer thickness by X-ray computed tomography (CT) showed homogenous distribution of coating layer thickness for the former product, whereas the latter product exhibited heterogeneous distribution within the tablet, as well as inconsistent trend in the thickness distribution between the tablets. It was suggested that this heterogeneity and inconsistent trend in layer thickness distribution contributed to the absence of correlation between the layer thickness of the face and side regions of the tablets, which resulted in the loss of correlation between the coating layer thickness and drug dissolution rate. Therefore, the predictability of drug dissolution rate from enteric-coated tablets depended on the homogeneity of the coating layer thickness. In addition, the importance of micro analysis, X-ray CT in this study, was suggested even if the macro analysis, NIRS in this study, are finally applied for the measurement. Copyright © 2017 Elsevier B.V. All rights reserved.
Perkins, T L; Green, R D; Hamlin, K E; Shepard, H H; Miller, M F
1992-09-01
The objective of this study was to determine technician effects of live animal ultrasonic estimates of fat thickness (FTU) and longissimus muscle area (LMAU). Steers (n = 36) representing four breed-types (Brown Swiss, Average Zebu-cross Mexican, Corriente Mexican, and typical British crossbred) of commercial slaughter cattle were isonified to estimate accuracy and repeatability of fat thickness (FT) and longissimus muscle area (LMA) measurements by two experienced technicians. Repeated measures of FTU and LMAU were taken by technicians on two consecutive days with an Aloka 500V ultrasound unit equipped with a 3.5-MHz, 172-mm scanning width, linear-array transducer. Ultrasonic estimates of fat thickness and LMAU were taken at the 12th and 13th rib interface 48 h before slaughter; carcass fat thickness (FTC) and longissimus muscle area (LMAC) were measured 48 h postmortem. Means for FTU, FTC, LMAU, and LMAC were .91 +/- .36 cm, .82 +/- .40 cm, 70.7 +/- 9.43 cm2, and 72.4 +/- 8.9 cm2, respectively. Ultrasound and carcass measures of FT and LMA were different (P less than .01) among breed-types but were not different (P greater than .10) between technicians or for technician x breed-type interactions. Pooled simple correlation coefficients (P less than .01) were .87 and .86 between FTU and FTC and .76 and .82 between LMAU and LMAC for Technicians 1 and 2, respectively. Repeatabilities estimated by intraclass correlation methods were .91 +/- .03 and .81 +/- .06 for images repeated over 2 d and .95 +/- .02 and .83 +/- .05 for images repeated by two technicians for FT and LMA, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)
Akyürek, Nesibe; Atabek, Mehmet Emre; Eklioglu, Beray Selver; Alp, Hayrullah
2015-06-01
Children with Turner syndrome (TS) have a broad range of later health problems, including an increased risk of cardiovascular morbidity and mortality. The aim of this study was to evaluate the relationship between periaortic fat thickness (PAFT) and metabolic and cardiovascular profiles in children with TS. Twenty-nine TS and 29 healthy children and adolescents were enrolled in the study. Anthropometric measurements, pubertal staging, and blood pressure measurements were performed. Fasting serum glucose, insulin, and lipid profile were measured. Periaortic fat thickness was measured using an echocardiography method, which has not previously been applied in children with TS. No difference was found between TS and control subject (CS) in age, weight, waist/hip ratio, HDL cholesterol and LDL cholesterol levels. However, in TS subjects, total cholesterol (p = 0.045) was greater than that in controls. It was determined that 13.7 % (N: 4) of TS subjects had dyslipidemia. Mean fasting glucose, fasting insulin, QUICK-I, HOMA, and FGIR index were similar in TS and in CS, whereas 17.2 % (N: 5) of TS subjects had insulin resistance (IR) and 13.7 % (N: 4) had impaired glucose tolerance. Six subjects (20.6 %) were diagnosed as hypertensive. Periaortic fat thickness was significantly higher in the TS group (p < 0.001) (0.1694 ± 0.025 mm in the TS group and 0.1416 ± 0.014 mm in the CS group) In children with TS, PAFT was positively correlated with fasting insulin, body mass index, and diastolic blood pressure. Our results provide additional evidence for the presence of subclinical cardiovascular disease in TS. In addition to existing methods, we recommend the measurement of periaortic fat thickness in children with TS to reveal the presence of early atherosclerosis.
Abdulrazzaq, Yousef M; Nagelkerke, Nico; Moussa, Mohamed A
2011-11-01
To determine a range of anthropometric measurements including skinfold thickness measurements in four different areas of the body, to construct population growth charts for body mass index (BMI), skinfolds, and to compare these with growth charts from other countries. One aim was also to validate body fat charts derived from skinfold thickness. A national cross-sectional growth survey of children, 0-18 years old, was conducted using multistage stratified random sampling. The sample size included at least 200 children in each age-sex group. Height, weight, biceps skinfold, triceps skinfold, subscapular skinfold, suprailiac skinfold, and mid-upper-arm circumference were measured in each child. We describe correlation, standard deviation scores relative to the other standards, and calculation of body density in the United Arab Emirates population. We determined whether any of the above is a good indicator of fatness in children. BMI, upper-arm circumference, sum of four skinfolds, and percentage body fat charts were constructed using the LMS method of smoothing. BMI was very significantly correlated with sum of skinfold thicknesses, and mid-upper-arm circumference. Prevalence of obesity and overweight in ages 13-17 years was respectively 9.94% and 15.16% in females and 6.08% and 14.16% in males. Derived body fat charts were found not to be accurate. A national BMI, upper-arm circumference, and sum of four skinfolds chart has been constructed that can be used as a reference standard for the United Arab Emirates. Sum of four skinfold thickness charts can be used as crude determinants of adiposity in children, but derived body fat charts were shown to be inaccurate.
Compliance of the abdominal wall during laparoscopic insufflation.
Becker, Chuck; Plymale, Margaret A; Wennergren, John; Totten, Crystal; Stigall, Kyle; Roth, J Scott
2017-04-01
To provide adequate workspace between the viscera and abdominal wall, insufflation with carbon dioxide is a common practice in laparoscopic surgeries. An insufflation pressure of 15 mmHg is considered to be safe in patients, but all insufflation pressures create perioperative and postoperative physiologic effects. As a composition of viscoelastic materials, the abdominal wall should distend in a predictable manner given the pressure of the pneumoperitoneum. The purpose of this study was to elucidate the relationship between degree of abdominal distention and the insufflation pressure, with the goal of determining factors which impact the compliance of the abdominal wall. A prospective, IRB-approved study was conducted to video record the abdomens of patients undergoing insufflation prior to a laparoscopic surgery. Photo samples were taken every 5 s, and the strain of the patient's abdomen in the sagittal plane was determined, as well as the insufflator pressure (stress) at bedside. Patients were insufflated to 15 mmHg. The relationship between the stress and strain was determined in each sample, and compliance of the patient's abdominal wall was calculated. Subcutaneous fat thickness and rectus abdominus muscle thickness were obtained from computed tomography scans. Correlations between abdominal wall compliances and subcutaneous fat and muscle content were determined. Twenty-five patients were evaluated. An increased fat thickness in the abdominal wall had a direct exponential relationship with abdominal wall compliance (R 2 = 0.59, p < 0.05). There was no correlation between muscle and fat thickness. All insufflation pressures create perioperative and postoperative complications. The compliance of patients' abdominal body walls differs, and subcutaneous fat thickness has a direct exponential relationship with abdominal wall compliance. Thus, insufflation pressures can be better tailored per the patient. Future studies are needed to demonstrate the clinical impact of varying insufflation pressures.
Sharma, N; Periasamy, C; Chaturvedi, N
2018-07-01
In this paper, we present an investigation of the impact of GaN capping layer and AlGaN layer thickness on the two-dimensional (2D)-electron mobility and the carrier concentration which was formed close to the AlGaN/GaN buffer layer for Al0.25Ga0.75N/GaN and GaN/Al0.25Ga0.75N/GaN heterostructures deposited on sapphire substrates. The results of our analysis clearly indicate that expanding the GaN capping layer thickness from 1 nm to 100 nm prompts an increment in the electron concentration at hetero interface. As consequence of which drain current was additionally increments with GaN cap layer thicknesses, and eventually saturates at approximately 1.85 A/mm for capping layer thickness greater than 40 nm. Interestingly, for the same structure, the 2D-electron mobility, decrease monotonically with GaN capping layer thickness, and saturate at approximately 830 cm2/Vs for capping layer thickness greater than 50 nm. A device with a GaN cap layer didn't exhibit gate leakage current. Furthermore, it was observed that the carrier concentration was first decrease 1.03 × 1019/cm3 to 6.65 × 1018/cm3 with AlGaN Layer thickness from 5 to 10 nm and after that it increases with the AlGaN layer thickness from 10 to 30 nm. The same trend was followed for electric field distributions. Electron mobility decreases monotonically with AlGaN layer thickness. Highest electron mobility 1354 cm2/Vs were recorded for the AlGaN layer thickness of 5 nm. Results obtained are in good agreement with published experimental data.
Using a conformal water bolus to adjust heating patterns of microwave waveguide applicators
NASA Astrophysics Data System (ADS)
Stauffer, Paul R.; Rodrigues, Dario B.; Sinahon, Randolf; Sbarro, Lyndsey; Beckhoff, Valeria; Hurwitz, Mark D.
2017-02-01
Background: Hyperthermia, i.e., raising tissue temperature to 40-45°C for 60 min, has been demonstrated to increase the effectiveness of radiation and chemotherapy for cancer. Although multi-element conformal heat applicators are under development to provide more adjustable heating of contoured anatomy, to date the most often used applicator to heat superficial disease is the simple microwave waveguide. With only a single power input, the operator must be resourceful to adjust heat treatment to accommodate variable size and shape tumors spreading across contoured anatomy. Methods: We used multiphysics simulation software that couples electromagnetic, thermal and fluid dynamics physics to simulate heating patterns in superficial tumors from commercially available microwave waveguide applicators. Temperature distributions were calculated inside homogenous muscle and layered skin-fat-muscle-tumor-bone tissue loads for a typical range of applicator coupling configurations and size of waterbolus. Variable thickness waterbolus was simulated as necessary to accommodate contoured anatomy. Physical models of several treatment configurations were constructed for comparison of simulation results with experimental specific absorption rate (SAR) measurements in homogenous muscle phantom. Results: Accuracy of the simulation model was confirmed with experimental SAR measurements of three unique applicator setups. Simulations demonstrated the ability to generate a wide range of power deposition patterns with commercially available waveguide antennas by controllably varying size and thickness of the waterbolus layer. Conclusion: Heating characteristics of 915 MHz waveguide antennas can be varied over a wide range by controlled adjustment of microwave power, coupling configuration, and waterbolus lateral size and thickness. The uniformity of thermal dose delivered to superficial tumors can be improved by cyclic switching of waterbolus thickness during treatment to proactively shift heat peaks and nulls around under the aperture, thereby reducing patient pain while increasing minimum thermal dose by end of treatment.
NASA Astrophysics Data System (ADS)
Atkinson, Callum; Coudert, Sebastien; Foucaut, Jean-Marc; Stanislas, Michel; Soria, Julio
2011-04-01
To investigate the accuracy of tomographic particle image velocimetry (Tomo-PIV) for turbulent boundary layer measurements, a series of synthetic image-based simulations and practical experiments are performed on a high Reynolds number turbulent boundary layer at Reθ = 7,800. Two different approaches to Tomo-PIV are examined using a full-volume slab measurement and a thin-volume "fat" light sheet approach. Tomographic reconstruction is performed using both the standard MART technique and the more efficient MLOS-SMART approach, showing a 10-time increase in processing speed. Random and bias errors are quantified under the influence of the near-wall velocity gradient, reconstruction method, ghost particles, seeding density and volume thickness, using synthetic images. Experimental Tomo-PIV results are compared with hot-wire measurements and errors are examined in terms of the measured mean and fluctuating profiles, probability density functions of the fluctuations, distributions of fluctuating divergence through the volume and velocity power spectra. Velocity gradients have a large effect on errors near the wall and also increase the errors associated with ghost particles, which convect at mean velocities through the volume thickness. Tomo-PIV provides accurate experimental measurements at low wave numbers; however, reconstruction introduces high noise levels that reduces the effective spatial resolution. A thinner volume is shown to provide a higher measurement accuracy at the expense of the measurement domain, albeit still at a lower effective spatial resolution than planar and Stereo-PIV.
Garza, Rebecca M; Paik, Kevin J; Chung, Michael T; Duscher, Dominik; Gurtner, Geoffrey C; Longaker, Michael T; Wan, Derrick C
2014-08-01
Following radiation therapy, skin becomes fibrotic and can present a difficult problem for reconstructive surgeons. There is an increasing belief that fat grafting under irradiated skin can reverse the damage caused by radiation. The present study evaluated the effect of fat grafting on irradiated skin, along with fat graft quality and retention rates in irradiated tissue. Nine adult Crl:NU-Foxn1 CD-1 mice underwent 30-Gy external beam irradiation of the scalp. Four weeks after irradiation, scalp skin from irradiated and nonirradiated mice was harvested and compared histologically for dermal thickness, collagen content, and vascular density. Human fat grafts were then injected in the subcutaneous plane of the scalp. Skin assessment was performed in the irradiated group at 2 and 8 weeks after grafting, and fat graft retention was measured at baseline and every 2 weeks up to 8 weeks after grafting using micro-computed tomography. Finally, fat graft samples were explanted at 8 weeks, and quality scoring was performed. Fat grafting resulted in decreased dermal thickness, decreased collagen content, and increased vascular density in irradiated skin. Computed tomographic analysis revealed significantly decreased fat graft survival in the irradiated group compared with the nonirradiated group. Histologic scoring of explanted fat grafts demonstrated no difference in quality between the irradiated and nonirradiated groups. Fat grafting attenuates dermal collagen deposition and vessel depletion characteristic of radiation fibrosis. Although fat graft retention rates are significantly lower in irradiated than in nonirradiated tissue, the quality of retained fat between the groups is similar.
Relationship Between Body Fatness and Performance in Preadolescent Children.
ERIC Educational Resources Information Center
Hensley, Larry D.; And Others
This study investigated the relationship between physical performance tests and body fatness in young children, and the extent to which differences in performance between the sexes could be explained by differences in body fatness. Measurements of age, height, weight, skinfold thicknesses, and performance scores on the vertical jump, standing…
Wanek, Justin; Blair, Norman P.; Chau, Felix Y.; Lim, Jennifer I.; Leiderman, Yannek I.; Shahidi, Mahnaz
2016-01-01
Purpose This article reports a method for en face optical coherence tomography (OCT) imaging and quantitative assessment of alterations in both thickness and reflectance of individual retinal layers at different stages of diabetic retinopathy (DR). Methods High-density OCT raster volume scans were acquired in 29 diabetic subjects divided into no DR (NDR) or non-proliferative DR (NPDR) groups and 22 control subjects (CNTL). A customized image segmentation method identified eight retinal layer interfaces and generated en face thickness maps and reflectance images for nerve fiber layer (NFL), ganglion cell and inner plexiform layers (GCLIPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL), photoreceptor outer segment layer (OSL), and retinal pigment epithelium (RPE). Mean thickness and intensity values were calculated in nine macular subfields for each retinal layer. Results En face thickness maps and reflectance images of retinal layers in CNTL subjects corresponded to normal retinal anatomy. Total retinal thickness correlated negatively with age in nasal subfields (R ≤−0.31; P ≤ 0.03, N = 51). In NDR subjects, NFL and OPL thickness were decreased (P = 0.05), and ONL thickness was increased (P = 0.04) compared to CNTL. In NPDR subjects, GCLIPL thickness was increased in perifoveal subfields (P < 0.05) and INL intensity was higher in all macular subfields (P = 0.04) compared to CNTL. Conclusions Depth and spatially resolved retinal thickness and reflectance measurements are potential biomarkers for assessment and monitoring of DR. PMID:27409491
Ma, Jun; Wang, Zhiqiang; Dong, Bin; Song, Yi; Hu, Peijin; Zhang, Bing
2012-11-14
Children in China are experiencing a rapid increase in the prevalence of obesity, which is associated with hypertension. To compare the effect of body fat on blood pressure (BP) with that of the normal physical growth, we compared BP levels in Chinese children with different body fat levels. In the present population-based study, 13 972 children in the highest-skinfold-thickness-quartile group were individually matched to 13 972 children in the lowest-skinfold-thickness-quartile group by height and weight. Similarly, 5103 children in the highest-waist-circumference-quartile group were matched to the same number of children in the lowest-waist-circumference-quartile group. The high- and low-fat groups had similar height and weight but the high-fat group had significantly higher skinfold and waist circumference measurements. The differences in systolic BP (SBP) between the high- and low-skinfold-thickness groups were small: 0·01 (95 % CI -0·41, 0·44) mmHg in boys and 0·20 (95 % CI -0·15, 0·54) mmHg in girls. The differences in diastolic BP (DBP) were also small (0·39 and 0·38 mmHg for boys and girls, respectively) but were statistically significant. The differences in both SBP and DBP between the high- and low-waist-circumference groups were small but not statistically significant. For a given body size as measured by height and weight, relative body fat had little impact on BP levels in these children. Fat mass and lean mass may have a similar quantitative impact on BP in healthy-weight children.
Effect of layer thickness on the elution of bulk-fill composite components.
Rothmund, Lena; Reichl, Franz-Xaver; Hickel, Reinhard; Styllou, Panorea; Styllou, Marianthi; Kehe, Kai; Yang, Yang; Högg, Christof
2017-01-01
An increment layering technique in a thickness of 2mm or less has been the standard to sufficiently convert (co)monomers. Bulk fill resin composites were developed to accelerate the restoration process by enabling up to 4mm thick increments to be cured in a single step. The aim of the present study is to investigate the effect of layer thickness on the elution of components from bulk fill composites. The composites ELS Bulk fill, SDR Bulk fill and Venus Bulkfill were polymerized according to the instruction of the manufacturers. For each composite three groups with four samples each (n=4) were prepared: (1) samples with a layer thickness of 2mm; (2) samples with a layer thickness of 4mm and (3) samples with a layer thickness of 6mm. The samples were eluted in methanol and water for 24h and 7 d. The eluates were analyzed by gas chromatography/mass spectrometry (GC/MS). A total of 11 different elutable substances have been identified from the investigated composites. Following methacrylates showed an increase of elution at a higher layer thickness: TEGDMA (SDR Bulk fill, Venus Bulk fill), EGDMA (Venus Bulk fill). There was no significant difference in the elution of HEMA regarding the layer thickness. The highest concentration of TEGDMA was 146μg/mL for SDR Bulk fill at a layer thickness of 6mm after 7 d in water. The highest HEMA concentration measured at 108μg/mL was detected in the methanol eluate of Venus Bulk fill after 7 d with a layer thickness of 6mm. A layer thickness of 4mm or more can lead to an increased elution of some bulk fill components, compared to the elution at a layer thickness of 2mm. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Beef quality parameters estimation using ultrasound and color images
2015-01-01
Background Beef quality measurement is a complex task with high economic impact. There is high interest in obtaining an automatic quality parameters estimation in live cattle or post mortem. In this paper we set out to obtain beef quality estimates from the analysis of ultrasound (in vivo) and color images (post mortem), with the measurement of various parameters related to tenderness and amount of meat: rib eye area, percentage of intramuscular fat and backfat thickness or subcutaneous fat. Proposal An algorithm based on curve evolution is implemented to calculate the rib eye area. The backfat thickness is estimated from the profile of distances between two curves that limit the steak and the rib eye, previously detected. A model base in Support Vector Regression (SVR) is trained to estimate the intramuscular fat percentage. A series of features extracted on a region of interest, previously detected in both ultrasound and color images, were proposed. In all cases, a complete evaluation was performed with different databases including: color and ultrasound images acquired by a beef industry expert, intramuscular fat estimation obtained by an expert using a commercial software, and chemical analysis. Conclusions The proposed algorithms show good results to calculate the rib eye area and the backfat thickness measure and profile. They are also promising in predicting the percentage of intramuscular fat. PMID:25734452
An evaluation of a bioelectrical impedance analyser for the estimation of body fat content.
Maughan, R J
1993-01-01
Measurement of body composition is an important part of any assessment of health or fitness. Hydrostatic weighing is generally accepted as the most reliable method for the measurement of body fat content, but is inconvenient. Electrical impedance analysers have recently been proposed as an alternative to the measurement of skinfold thickness. Both these latter methods are convenient, but give values based on estimates obtained from population studies. This study compared values of body fat content obtained by hydrostatic weighing, skinfold thickness measurement and electrical impedance on 50 (28 women, 22 men) healthy volunteers. Mean(s.e.m.) values obtained by the three methods were: hydrostatic weighing, 20.5(1.2)%; skinfold thickness, 21.8(1.0)%; impedance, 20.8(0.9)%. The results indicate that the correlation between the skinfold method and hydrostatic weighing (0.931) is somewhat higher than that between the impedance method and hydrostatic weighing (0.830). This is, perhaps, not surprising given the fact that the impedance method is based on an estimate of total body water which is then used to calculate body fat content. The skinfold method gives an estimate of body density, and the assumptions involved in the conversion from body density to body fat content are the same for both methods. PMID:8457817
Vitturi, Nicola; Soattin, Marta; De Stefano, Fabio; Vianello, Daniela; Zambon, Alberto; Plebani, Mario; Busetto, Luca
2015-06-01
The aim of our study was the evaluation of anthropometric measurements [waist circumference and sagittal abdominal diameter (SAD)] and abdominal bioelectrical impedance analysis (BIA) (ViScan, TANITA) in comparison to several abdominal ultrasonographic (US) measurements to estimate visceral fat deposition and liver steatosis in a population of 105 subjects. All 105 patients underwent a complete anthropometric evaluation, blood sample for the determination of total cholesterol, HDL cholesterol, triglycerides, glucose, insulin, high-sensitivity C-reactive protein, BIA and US measurements (peritoneal, pre-peritoneal, peri-renal, para-renal and peri-hepatic fat thickness). All the ultrasonographic markers considered in our study are related to the presence of non-alcoholic fatty liver disease (NAFLD), and so is true for SAD. Comparing ROC curves, peritoneal fat tissue thickness, SAD and ViScan visceral index are significantly better than waist circumference in predicting the presence of NAFLD (AUC 0.79 ± 0.04; 0.81 ± 0.05; 0.82 ± 0.04 vs 0.76 ± 0.05, respectively). According to our data, various methods may be useful in evaluating NAFLD, but only ViScan visceral index, US peritoneal fat thickness and SAD are better than waist circumference. Among them, SAD is the most promising, due to its small cost and time consumption.
Niklowitz, Petra; Rothermel, Juliane; Lass, Nina; Barth, Andre; Reinehr, Thomas
2018-05-01
This study analyzed the relationships between bioactive leptin, conventionally measured leptin, and parameters of fat mass and distribution in obese children before and after weight reduction. We determined bioactive leptin (bioLep), conventional measured leptin (conLep), weight, height, body fat based on skinfold measurements and bioimpedance analyses, waist circumference (wc), and pubertal stage in 88 obese children participating in a lifestyle intervention at baseline and one year later. We identified no child with homozygous or heterozygous status for bioinactive leptin mutations. The baseline associations between bioLep and BMI (r = 0.53), BMI-SDS (r = 0.48), body fat (bioimpedance: r = 0.61, skinfold thickness: r = 0.49), wc (r = 0.42), and waist to height ratio (whr) (r = 0.39) were stronger than the associations between conLep and BMI (r = 0.50), BMI-SDS (r = 0.44), body fat (bioimpedance: r = 0.57, skinfold thickness: r = 0.41), wc (r = 0.41), and whr (r = 0.37). The changes of bioLep were stronger related to changes of BMI-SDS (r = 0.54), body fat (bioimpedance r = 0.59, skinfold thickness: r = 0.37), wc (r = 0.22), and whr (r = 0.21) than the associations between changes of conLep and changes of BMI-SDS (r = 0.48), body fat (bioimpedance: r = 0.56, skinfold thickness: r = 0.43), wc (r = 0.20), and whr (r = 0.20). The same findings were observed in multiple linear regression analyses adjusted to multiple confounders. In contrast to changes of conLep (r = 0.22), the changes of bioLep during intervention were not related to weight regain after the end of intervention. BioLep concentrations did not differ between prepubertal girls and boys, but were higher in pubertal girls compared to pubertal boys (p = 0.031). Bioactive leptin was stronger related to fat mass and distribution compared to conventionally measured leptin. Copyright © 2018 Elsevier B.V. All rights reserved.
Tissue oxygenation and haemodynamics measurement with spatially resolved NIRS
NASA Astrophysics Data System (ADS)
Zhang, Y.; Scopesi, F.; Serra, G.; Sun, J. W.; Rolfe, P.
2010-08-01
We describe the use of Near Infrared Spectroscopy (NIRS) for the non-invasive investigation of changes in haemodynamics and oxygenation of human peripheral tissues. The goal was to measure spatial variations of tissue NIRS oxygenation variables, namely deoxy-haemoglobin (HHb), oxy-haemoglobin (HbO2), total haemoglobin (HbT), and thereby to evaluate the responses of the peripheral circulation to imposed physiological challenges. We present a skinfat- muscle heterogeneous tissue model with varying fat thickness up to 15mm and a Monte Carlo simulation of photon transport within this model. The mean partial path length and the mean photon visit depth in the muscle layer were derived for different source-detector spacing. We constructed NIRS instrumentation comprising of light-emitting diodes (LED) as light sources at four wavelengths, 735nm, 760nm, 810nm and 850nm and sensitive photodiodes (PD) as the detectors. Source-detector spacing was varied to perform measurements at different depths within forearm tissue. Changes in chromophore concentration in response to venous and arterial occlusion were calculated using the modified Lambert-Beer Law. Studies in fat and thin volunteers indicated greater sensitivity in the thinner subjects for the tissue oxygenation measurement in the muscle layer. These results were consistent with those found using Monte Carlo simulation. Overall, the results of this investigation demonstrate the usefulness of the NIRS instrument for deriving spatial information from biological tissues.
Shin, Ji Soo
2017-01-01
Purpose The aim of this study was to evaluate the changes in thickness of each macular retinal layer, the peripapillary retinal nerve fiber layer (RNFL), and central macular thickness (CMT) after 577-nm pattern scanning laser (PASCAL) photocoagulation in patients with diabetic retinopathy. Methods This retrospective study included 33 eyes with diabetic retinopathy that underwent 577-nm PASCAL photocoagulation. Each retinal layer thickness, peripapillary RNFL thickness, and CMT were measured by spectral-domain optical coherence tomography before 577-nm PASCAL photocoagulation, as well as at 1, 6, and 12 months after 577-nm PASCAL photocoagulation. Computerized intraretinal segmentation of optical coherence tomography was performed to identify the thickness of each retinal layer. Results The average thickness of the RNFL, ganglion cell layer, inner plexiform layer, inner nuclear layer, inner retinal layer, and CMT at each follow-up increased significantly from baseline (p < 0.001), whereas that of the retinal pigment epithelium at each follow-up decreased significantly from baseline (p < 0.001). The average thickness of the peripapillary RNFL increased significantly at one month (p < 0.001). This thickness subsequently recovered to 7.48 µm, and there were no significant changes at six or 12 months compared to baseline (p > 0.05). Conclusions Each macular retinal layer and CMT had a tendency to increase for one year after 577-nm PASCAL photocoagulation, whereas the average thickness of retinal pigment epithelium decreased at one-year follow-up compared to the baseline. Although an increase in peripapillary RNFL thickness was observed one month after 577-nm PASCAL photocoagulation, there were no significant changes at the one-year follow-up compared to the baseline. PMID:29022292
Shin, Ji Soo; Lee, Young Hoon
2017-12-01
The aim of this study was to evaluate the changes in thickness of each macular retinal layer, the peripapillary retinal nerve fiber layer (RNFL), and central macular thickness (CMT) after 577-nm pattern scanning laser (PASCAL) photocoagulation in patients with diabetic retinopathy. This retrospective study included 33 eyes with diabetic retinopathy that underwent 577-nm PASCAL photocoagulation. Each retinal layer thickness, peripapillary RNFL thickness, and CMT were measured by spectral-domain optical coherence tomography before 577-nm PASCAL photocoagulation, as well as at 1, 6, and 12 months after 577-nm PASCAL photocoagulation. Computerized intraretinal segmentation of optical coherence tomography was performed to identify the thickness of each retinal layer. The average thickness of the RNFL, ganglion cell layer, inner plexiform layer, inner nuclear layer, inner retinal layer, and CMT at each follow-up increased significantly from baseline (p < 0.001), whereas that of the retinal pigment epithelium at each follow-up decreased significantly from baseline (p < 0.001). The average thickness of the peripapillary RNFL increased significantly at one month (p < 0.001). This thickness subsequently recovered to 7.48 μm, and there were no significant changes at six or 12 months compared to baseline (p > 0.05). Each macular retinal layer and CMT had a tendency to increase for one year after 577-nm PASCAL photocoagulation, whereas the average thickness of retinal pigment epithelium decreased at one-year follow-up compared to the baseline. Although an increase in peripapillary RNFL thickness was observed one month after 577-nm PASCAL photocoagulation, there were no significant changes at the one-year follow-up compared to the baseline. © 2017 The Korean Ophthalmological Society
Cloud layer thicknesses from a combination of surface and upper-air observations
NASA Technical Reports Server (NTRS)
Poore, Kirk D.; Wang, Junhong; Rossow, William B.
1995-01-01
Cloud layer thicknesses are derived from base and top altitudes by combining 14 years (1975-1988) of surface and upper-air observations at 63 sites in the Northern Hemisphere. Rawinsonde observations are employed to determine the locations of cloud-layer top and base by testing for dewpoint temperature depressions below some threshold value. Surface observations serve as quality checks on the rawinsonde-determined cloud properties and provide cloud amount and cloud-type information. The dataset provides layer-cloud amount, cloud type, high, middle, or low height classes, cloud-top heights, base heights and layer thicknesses, covering a range of latitudes from 0 deg to 80 deg N. All data comes from land sites: 34 are located in continental interiors, 14 are near coasts, and 15 are on islands. The uncertainties in the derived cloud properties are discussed. For clouds classified by low-, mid-, and high-top altitudes, there are strong latitudinal and seasonal variations in the layer thickness only for high clouds. High-cloud layer thickness increases with latitude and exhibits different seasonal variations in different latitude zones: in summer, high-cloud layer thickness is a maximum in the Tropics but a minimum at high latitudes. For clouds classified into three types by base altitude or into six standard morphological types, latitudinal and seasonal variations in layer thickness are very small. The thickness of the clear surface layer decreases with latitude and reaches a summer minimum in the Tropics and summer maximum at higher latitudes over land, but does not vary much over the ocean. Tropical clouds occur in three base-altitude groups and the layer thickness of each group increases linearly with top altitude. Extratropical clouds exhibit two groups, one with layer thickness proportional to their cloud-top altitude and one with small (less than or equal to 1000 m) layer thickness independent of cloud-top altitude.
Yoshimura, Aya; Ohnishi, Shunsuke; Orito, Chieko; Kawahara, Yukako; Takasaki, Hiroyo; Takeda, Hiroshi; Sakamoto, Naoya; Hashino, Satoshi
2015-01-01
Obesity has been demonstrated to be associated with elevated leukocytes in adults and children. This study assessed the associations between peripheral total and differential leukocyte counts and obesity-related complications in young adults. 12 obese (median age 21.5 (range 19-28) years, median BMI 35.7 (range 32.0-44.9) kg/m(2)) and 11 normal (median age 23 (range 18-27) years, median BMI 19.5 (range 18.1-21.7) kg/m(2)) adults were enrolled. Complete blood count and serum levels of liver enzymes, fasting blood glucose, insulin and lipids were measured, and the homeostasis model assessment of insulin resistance was calculated. Fat mass was calculated using a bioimpedance analysis device, and ultrasonography was performed to measure fat thickness and to detect fatty change of the liver. Total leukocyte and monocyte counts were significantly increased in obese young adults. Total leukocyte count was associated with liver enzyme levels, insulin resistance as well as visceral and subcutaneous fat thickness. Neutrophil count was associated with insulin resistance. Lymphocyte count was associated with serum liver enzymes, insulin resistance, and dyslipidemia. Monocyte count was associated with serum liver enzyme, insulin resistance, visceral and subcutaneous fat thickness, body fat mass, and percentage body fat. The results of this study suggest that chronic low-grade systemic inflammation is associated with obesity-related complications such as nonalcoholic fatty liver disease, insulin resistance, and dyslipidemia in young adults. © 2015 S. Karger GmbH, Freiburg.
Reproducibility of abdominal fat assessment by ultrasound and computed tomography
Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge
2017-01-01
Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility. PMID:28670024
Reproducibility of abdominal fat assessment by ultrasound and computed tomography.
Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge
2017-01-01
To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.
Silaghi, Alina Cristina; Poantă, Laura; Valea, Ana; Pais, Raluca; Silaghi, Horatiu
2011-03-01
Epicardial adipose tissue is an ectopic fat storage at the heart surface in direct contact with the coronary arteries. It is considered a metabolically active tissue, being a local source of pro-inflammatory factors that contribute to the pathogenesis of coronary artery disease. The AIM of our study was to establish correlations between echocardiographic assessment of epicardial adipose tissue and anthropometric and ultrasound measurements of the central and peripheral fat depots. The study was conducted on 22 patients with or without coronaropathy. Epicardial adipose tissue was measured using Aloka Prosound α 10 machine with a 3.5-7.5 MHz variable-frequency transducer and subcutaneous and visceral fat with Esaote Megas GPX machine and 3.5-7.5 MHz variable frequency transducer. Epicardial adipose tissue measured by echocardiography is correlated with waist circumference (p < 0.05), visceral adipose tissue thickness measured by ultrasonography (US) and is not correlated with body mass index (p = 0.315), hip and thigh circumference or subcutaneous fat thickness measured by US. Our study confirms that US assessment of epicardial fat correlates with anthropometric and US measurements of the central fat, representing an indirect but reliable marker of the visceral fat.
Kuyumcu, Mehmet Emin; Halil, Meltem; Kara, Özgür; Çuni, Bledjan; Çağlayan, Gökhan; Güven, Serdar; Yeşil, Yusuf; Arık, Güneş; Yavuz, Burcu Balam; Cankurtaran, Mustafa; Özçakar, Levent
2016-01-01
To sonographically assess the muscle mass and architecture of sarcopenic elderly subjects, and to explore the utility of ultrasound (US) measurements in predicting sarcopenia. One hundred elderly subjects were enrolled in this cross-sectional study. Mean age value of our study population was 73.08±6.18years. The diagnosis of sarcopenia was confirmed by measuring fat-free mass index (using bioelectrical impedance analysis) and handgrip strength. Calf circumference was measured and US evaluations comprised bilateral gastrocnemius muscle (MG) thickness, fascicle length and pennate angles; subcutaneous fat and dermis thicknesses in the calf. Bilateral muscle thickness and fascicle length values were significantly lower in patients with sarcopenia (both p<0.05). Sarcopenic and nonsarcopenic subjects had similar pennate angles, subcutaneous fat and dermis thicknesses. Median thickness ratio (100×t (MG)/[t (subcutaneous tissue)+t (dermis)+t (MG)]) values were 64% (40-88%) in the right and 64% (38-86%) in the left calf. Bilateral MG thickness and fascicle length values showed high sensitivity in predicting sarcopenia (all values>76.92%). Gastrocnemius muscle thickness and fascicle length values are lower in sarcopenic elderly and these two parameters can serve as alternative measurements for predicting/quantifying sarcopenia. Calf circumference measurements alone may not be appropriate for assessing sarcopenia. Instead, US imaging can conveniently be used to evaluate different compartments of the musculoskelal system in (sarcopenic) elderly. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Lei, Hong; Chen, Xiao; Hu, Dong-Gang; Chen, Yu-Ting; Feng, Li-Cheng; Chen, Zhen-Yan; Li, Fang
2016-10-25
To evaluate the efficacy of electroacupuncture (EA) therapy on abdominal fat in obese women by using magnetic resonance imaging(MRI). Thirty abdominal obesity women patients were randomly divided into control group ( n =15) and EA group ( n =15). The obesity patients of the control group did not receive any treatment for weight reduction, and those of the EA group were treated by EA stimulation of bilateral Neiting (ST 44), Fenglong (ST 40), Zusanli (ST 36), Huaroumen (ST 24), Tianshu (ST 25), Wailing (ST 26), Shuidao (ST 28), Fujie (SP 14), Daheng (SP 13), etc. for 25 min, once every other day, 3 times per week for 3 months. The patient's body weight, height, waist circumference (WC) were mea-sured with different devices, and the body mass index (BMI) was calculated, and the subcutaneous adipose tissue thickness at the inferior edges of L 4 , L 5 and S 3 and the superior edge of the pubic symphysis and the total abdominal fat volume between the L 4 and S 3 levels were detected using MRI systems before and after the treatment. The effects of the EA group were significantly superior to those of the control group in lowering difference values (between pre- and post-treatment) of BMI, WC and subcutaneous adipose tissue thickness at the levels of the inferior edges of L 4 , L 5 , S 3 and the superior edge of the pubic symphysis(all P <0.01)and in reducing total abdominal fat volume between L 4 and S 3 (all P <0.01). After the treatment, the subcutaneous adipose tissue thickness at the superior edge of the pubic symphysis ( P <0.01) and the total abdominal fat volume between L 4 and S 3 ( P <0.05) were significantly decreased in the EA group compared to pre-treatment. There were no significant differences between post- and pre-treatment in BMI, WC, subcutaneous adipose tissue thickness at the levels of the L 4 , L 5 and S 3 in both EA and control groups and in the subcutaneous adipose tissue thickness at the level of the superior edge of the pubic symphysis and the total abdominal fat volume between L 4 and S 3 in the control group ( P >0.05). EA intervention can effectively reduce abdominal fat in obese women based on the evaluation of MRI.
Gross anatomy of superficial fascia and future localised fat deposit areas of the abdomen in foetus.
Kumar, Pramod; Pandey, Arvind Kumar; Kumar, Brijesh; Aithal, K S; Dsouza, Antony Sylvan
2013-09-01
The development and popularity of body contouring procedures such as liposuction and abdominoplasty has renewed interest in the anatomy of the superficial fascia and subcutaneous fat deposits of the abdomen. The study of anatomy of fascia and fetal adipose tissue was proposed as it may be of value in understanding the possible programing of prevention of obesity. The present study was undertaken to understand the gross anatomy of superficial fascia of abdomen and to study the gross anatomy of future localized fat deposits (LFDs) area of abdomen in fetus. Four fetus (two male & two female) of four month of intrauterine life were dissected. Attachments & layers of superficial fascia and future subcutaneous fat deposit area of upper and lower abdomen were noted. Superficial fascia of the abdomen was multi layered in mid line and number of layers reduced laterally as in adult. The future abdominal LFD (localized fat deposits) area in fetus shows brownish-white blubbary tissue without well-defined adult fat lobules. The attachment and gross anatomy of superficial fascia of the fetus was similar to that in adults. The future LFD areas showed brownish white blubbary tissue with ill-defined fat lobules.
ERIC Educational Resources Information Center
Hannon, James C.; Ratliffe, Thomas; Williams, Daniel P.
2006-01-01
The body mass index (BMI), or the ratio of weight in kilograms to the square of height in meters, is widely used to determine the presence or absence of overweight and obesity in adults. Although many consider BMI an acceptable clinical surrogate of body fatness, it does not differentiate between fat and fat-free tissues. Thus, children and…
Lee, Rebecca; Perry, Beth; Heywood, Jonathan; Reese, Charles; Bonner, Michael; Hatfield, Corey M.; Silver, Richard M.; Visconti, Richard P.; Hoffman, Stanley; Tourkina, Elena
2014-01-01
In fibrotic diseases caveolin-1 underexpression in fibroblasts results in collagen overexpression and in monocytes leads to hypermigration. These profibrotic behaviors are blocked by the caveolin-1 scaffolding domain peptide (CSD) which compensates for caveolin-1 deficiency. Monocytes and fibroblasts are related in that monocytes are the progenitors of fibrocytes (CD45+/Collagen I+ cells) that, in turn, are the progenitors of many fibroblasts in fibrotic tissues. In an additional anti-fibrotic activity, CSD blocks monocyte differentiation into fibrocytes. We studied a mouse fibrosis model (Pump Model) involving systemic bleomycin delivery that closely models scleroderma (SSc) in several ways, the most important of which for this study is that fibrosis is observed in the lungs, skin, and internal organs. We show here that dermal thickness is increased 2-fold in the Pump Model and that this effect is almost completely blocked by CSD (p < 0.001). Concomitantly, the subcutaneous fat layer becomes >80% thinner. This effect is also blocked by CSD (p < 0.001). Even in mice receiving vehicle instead of bleomycin, CSD increases the thickness of the fat layer. To study the mechanisms of action of bleomycin and CSD, we examined the accumulation of the chemokine receptor CCR5 and its ligands MIP1α and MIP1β in fibrotic tissue and their roles in monocyte migration. Fibrocytes and other leukocytes expressing CCR5 and its ligands were present at high levels in the fibrotic dermis of SSc patients and Pump Model mice while CSD blocked their accumulation in mouse dermis. Migration toward CCR5 ligands of SSc monocytes and Pump Model bone marrow cells was 3-fold greater than cells from control subjects. This enhanced migration was almost completely blocked by CSD. These results suggest that low monocyte caveolin-1 promotes fibrosis by enhancing the recruitment of fibrocytes and their progenitors into affected tissue. PMID:24966836
Bornelöv, Susanne; Seroussi, Eyal; Yosefi, Sara; Benjamini, Sharon; Miyara, Shoval; Ruzal, Mark; Grabherr, Manfred; Rafati, Nima; Molin, Anna-Maja; Pendavis, Ken; Burgess, Shane C; Andersson, Leif; Friedman-Einat, Miriam
2018-04-26
The mammalian adipose tissue plays a central role in energy-balance control, whereas the avian visceral fat hardly expresses leptin, the key adipokine in mammals. Therefore, to assess the endocrine role of adipose tissue in birds, we compared the transcriptome and proteome between two metabolically different types of chickens, broilers and layers, bred towards efficient meat and egg production, respectively. Broilers and layer hens, grown up to sexual maturation under free-feeding conditions, differed 4.0-fold in weight and 1.6-fold in ovarian-follicle counts, yet the relative accumulation of visceral fat was comparable. RNA-seq and mass-spectrometry (MS) analyses of visceral fat revealed differentially expressed genes between broilers and layers, 1106 at the mRNA level (FDR ≤ 0.05), and 203 at the protein level (P ≤ 0.05). In broilers, Ingenuity Pathway Analysis revealed activation of the PTEN-pathway, and in layers increased response to external signals. The expression pattern of genes encoding fat-secreted proteins in broilers and layers was characterized in the RNA-seq and MS data, as well as by qPCR on visceral fat under free feeding and 24 h-feed deprivation. This characterization was expanded using available RNA-seq data of tissues from red junglefowl, and of visceral fat from broilers of different types. These comparisons revealed expression of new adipokines and secreted proteins (LCAT, LECT2, SERPINE2, SFTP1, ZP1, ZP3, APOV1, VTG1 and VTG2) at the mRNA and/or protein levels, with dynamic gene expression patterns in the selected chicken lines (except for ZP1; FDR/P ≤ 0.05) and feed deprivation (NAMPT, SFTPA1 and ZP3) (P ≤ 0.05). In contrast, some of the most prominent adipokines in mammals, leptin, TNF, IFNG, and IL6 were expressed at a low level (FPKM/RPKM< 1) and did not show differential mRNA expression neither between broiler and layer lines nor between fed vs. feed-deprived chickens. Our study revealed that RNA and protein expression in visceral fat changes with selective breeding, suggesting endocrine roles of visceral fat in the selected phenotypes. In comparison to gene expression in visceral fat of mammals, our findings points to a more direct cross talk of the chicken visceral fat with the reproductive system and lower involvement in the regulation of appetite, inflammation and insulin resistance.
Jafarpoor, Mina; Li, Jia; White, Jacob K; Rutkove, Seward B
2013-05-01
Electrical impedance myography (EIM) is a technique for the evaluation of neuromuscular diseases, including amyotrophic lateral sclerosis and muscular dystrophy. In this study, we evaluated how alterations in the size and conductivity of muscle and thickness of subcutaneous fat impact the EIM data, with the aim of identifying an optimized electrode configuration for EIM measurements. Finite element models were developed for the human upper arm based on anatomic data; material properties of the tissues were obtained from rat and published sources. The developed model matched the frequency-dependent character of the data. Of the three major EIM parameters, resistance, reactance, and phase, the reactance was least susceptible to alterations in the subcutaneous fat thickness, regardless of electrode arrangement. For example, a quadrupling of fat thickness resulted in a 375% increase in resistance at 35 kHz but only a 29% reduction in reactance. By further optimizing the electrode configuration, the change in reactance could be reduced to just 0.25%. For a fixed 30 mm distance between the sense electrodes centered between the excitation electrodes, an 80 mm distance between the excitation electrodes was found to provide the best balance, with a less than 1% change in reactance despite a doubling of subcutaneous fat thickness or halving of muscle size. These analyses describe a basic approach for further electrode configuration optimization for EIM.
Horlick, Mary; Berenson, Gerald S
2013-01-01
Background: Although estimation of percentage body fat with the Slaughter skinfold-thickness equations (PBFSlaughter) is widely used, the accuracy of this method has not been well studied. Objective: The objective was to determine the accuracy of the Slaughter skinfold-thickness equations. Design: We compared agreement between PBFSlaughter and estimations derived from dual-energy X-ray absorptiometry (PBFDXA) in 1169 children in the Pediatric Rosetta Body Composition Project and the relation to cardiovascular disease risk factors, as compared with body mass index (BMI), in 6725 children in the Bogalusa Heart Study. Results: PBFSlaughter was highly correlated (r = 0.90) with PBFDXA, but it markedly overestimated levels of PBFDXA in children with large skinfold thicknesses. In the 65 boys with a sum of skinfold thicknesses (subscapular- plus triceps-skinfold thicknesses) ≥50 mm, PBFSlaughter overestimated PBFDXA by 12 percentage points. The comparable overestimation in girls with a high skinfold sum was 6 percentage points. We also found that, after adjustment for sex and age, BMI showed slightly stronger associations with lipid, lipoprotein, insulin, and blood pressure values than did PBFSlaughter. Conclusions: These results indicate that PBFSlaughter, which was developed among a group of much thinner children and adolescents, is fairly accurate among nonobese children, but markedly overestimates the body fatness of children who have thick skinfold thicknesses. Furthermore, PBFSlaughter has no advantage over sex- and age-adjusted BMIs at identifying children who are at increased risk of cardiovascular disease based on lipid, lipoprotein, insulin, and blood pressure values. PMID:24153344
NASA Astrophysics Data System (ADS)
Kuru, Hilal; Kockar, Hakan; Alper, Mursel
2017-12-01
Giant magnetoresistance (GMR) behavior in electrodeposited NiFe/Cu multilayers was investigated as a function of non-magnetic (Cu) and ferromagnetic (NiFe) layer thicknesses, respectively. Prior to the GMR analysis, structural and magnetic analyses of the multilayers were also studied. The elemental analysis of the multilayers indicated that the Cu and Ni content in the multilayers increase with increasing Cu and NiFe layer thickness, respectively. The structural studies by X-ray diffraction revealed that all multilayers have face centred cubic structure with preferred (1 1 0) crystal orientation as their substrates. The magnetic properties studied with the vibrating sample magnetometer showed that the magnetizations of the samples are significantly affected by the layer thicknesses. Saturation magnetisation, Ms increases from 45 to 225 emu/cm3 with increasing NiFe layer thickness. The increase in the Ni content of the multilayers with a small Fe content causes an increase in the Ms. And, the coercivities ranging from 2 to 24 Oe are between the soft and hard magnetic properties. Also, the magnetic easy axis of the multilayers was found to be in the film plane. Magnetoresistance measurements showed that all multilayers exhibited the GMR behavior. The GMR magnitude increases with increasing Cu layer thickness and reaches its maximum value of 10% at the Cu layer thickness of 1 nm, then it decreases. And similarly, the GMR magnitude increases and reaches highest value of pure GMR (10%) for the NiFe layer thickness of 3 nm, and beyond this point GMR decreases with increasing NiFe layer thickness. Some small component of the anisotropic magnetoresistance was also observed at thin Cu and thick NiFe layer thicknesses. It is seen that the highest GMR values up to 10% were obtained in electrodeposited NiFe/Cu multilayers up to now. The structural, magnetic and magnetoresistance properties of the NiFe/Cu were reported via the variations of the thicknesses of Cu and NiFe layers with stressing the role of layer thicknesses on the high GMR behavior.
Zone compensated multilayer laue lens and apparatus and method of fabricating the same
Conley, Raymond P.; Liu, Chian Qian; Macrander, Albert T.; Yan, Hanfei; Maser, Jorg; Kang, Hyon Chol; Stephenson, Gregory Brian
2015-07-14
A multilayer Laue Lens includes a compensation layer formed in between a first multilayer section and a second multilayer section. Each of the first and second multilayer sections includes a plurality of alternating layers made of a pair of different materials. Also, the thickness of layers of the first multilayer section is monotonically increased so that a layer adjacent the substrate has a minimum thickness, and the thickness of layers of the second multilayer section is monotonically decreased so that a layer adjacent the compensation layer has a maximum thickness. In particular, the compensation layer of the multilayer Laue lens has an in-plane thickness gradient laterally offset by 90.degree. as compared to other layers in the first and second multilayer sections, thereby eliminating the strict requirement of the placement error.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uribe, Fernando; Vianco, Paul Thomas; Zender, Gary L.
A study was performed that examined the microstructure and mechanical properties of 63Sn-37Pb (wt.%, Sn-Pb) solder joints made to thick film layers on low-temperature co-fired (LTCC) substrates. The thick film layers were combinations of the Dupont{trademark} 4596 (Au-Pt-Pd) conductor and Dupont{trademark} 5742 (Au) conductor, the latter having been deposited between the 4596 layer and LTCC substrate. Single (1x) and triple (3x) thicknesses of the 4596 layer were evaluated. Three footprint sizes were evaluated of the 5742 thick film. The solder joints exhibited excellent solderability of both the copper (Cu) lead and thick film surface. In all test sample configurations, themore » 5742 thick film prevented side wall cracking of the vias. The pull strengths were in the range of 3.4-4.0 lbs, which were only slightly lower than historical values for alumina (Al{sub 2}O{sub 3}) substrates. General (qualitative) observations: (a) The pull strength was maximized when the total number of thick film layers was between two and three. Fewer that two layers did not develop as strong of a bond at the thick film/LTCC interface; more than three layers and of increased footprint area, developed higher residual stresses at the thick film/LTCC interface and in the underlying LTCC material that weakened the joint. (b) Minimizing the area of the weaker 4596/LTCC interface (e.g., larger 5742 area) improved pull strength. Specific observations: (a) In the presence of vias and the need for the 3x 4596 thick film, the preferred 4596:5742 ratio was 1.0:0.5. (b) For those LTCC components that require the 3x 4596 layer, but do not have vias, it is preferred to refrain from using the 5742 layer. (c) In the absence of vias, the highest strength was realized with a 1x thick 5742 layer, a 1x thick 4596 layer, and a footprint ratio of 1.0:1.0.« less
Spectral ellipsometry as a method for characterization of nanosized films with ferromagnetic layers
NASA Astrophysics Data System (ADS)
Hashim, H.; Singkh, S. P.; Panina, L. V.; Pudonin, F. A.; Sherstnev, I. A.; Podgornaya, S. V.; Shpetnyi, I. A.; Beklemisheva, A. V.
2017-11-01
Nanosized films with ferromagnetic layers are widely used in nanoelectronics, sensor systems and telecommunications. Their properties may strongly differ from those of bulk materials that is on account of interfaces, intermediate layers and diffusion. In the present work, spectral ellipsometry and magnetooptical methods are adapted for characterization of the optical parameters and magnetization processes in two- and three-layer Cr/NiFe, Al/NiFe and Cr(Al)/Ge/NiFe films onto a sitall substrate for various thicknesses of Cr and Al layers. At a layer thickness below 20 nm, the complex refractive coefficients depend pronouncedly on the thickness. In two-layer films, remagnetization changes weakly over a thickness of the top layer, but the coercive force in three-layer films increases by more than twice upon remagnetization, while increasing the top layer thickness from 4 to 20 nm.
Watanabe, Tomoya; Mlakar, Logan; Heywood, Jonathan; Malaab, Maya; Hoffman, Stanley
2017-01-01
The murine bleomycin (BLM)-induced fibrosis model is the most widely used in systemic sclerosis (SSc) studies. It has been reported that systemic delivery of BLM via continuous diffusion from subcutaneously implanted osmotic minipumps can cause fibrosis of the skin, lungs, and other internal organs. However, the mouse strain, dosage of BLM, administration period, and additional important features differ from one report to the next. In this study, by employing the pump model in C57BL/6J mice, we show a dose-dependent increase in lung fibrosis by day 28 and a transient increase in dermal thickness. Dermal thickness and the level of collagen in skin treated with high-dose BLM was significantly higher than in skin treated with low dose BLM or vehicle. A reduction in the thickness of the adipose layer was noted in both high and low dose groups at earlier time points suggesting that the loss of the fat layer precedes the onset of fibrosis. High-dose BLM also induced dermal fibrosis and increased expression of fibrosis-associated genes ex vivo in human skin, thus confirming and extending the in vivo findings, and demonstrating that a human organ culture model can be used to assess the effect of BLM on skin. In summary, our findings suggest that the BLM pump model is an attractive model to analyze the underlying mechanisms of fibrosis and test the efficacy of potential therapies. However, the choice of mouse strain, duration of BLM administration and dose must be carefully considered when using this model. PMID:28651005
Watanabe, Tomoya; Nishimoto, Tetsuya; Mlakar, Logan; Heywood, Jonathan; Malaab, Maya; Hoffman, Stanley; Feghali-Bostwick, Carol
2017-01-01
The murine bleomycin (BLM)-induced fibrosis model is the most widely used in systemic sclerosis (SSc) studies. It has been reported that systemic delivery of BLM via continuous diffusion from subcutaneously implanted osmotic minipumps can cause fibrosis of the skin, lungs, and other internal organs. However, the mouse strain, dosage of BLM, administration period, and additional important features differ from one report to the next. In this study, by employing the pump model in C57BL/6J mice, we show a dose-dependent increase in lung fibrosis by day 28 and a transient increase in dermal thickness. Dermal thickness and the level of collagen in skin treated with high-dose BLM was significantly higher than in skin treated with low dose BLM or vehicle. A reduction in the thickness of the adipose layer was noted in both high and low dose groups at earlier time points suggesting that the loss of the fat layer precedes the onset of fibrosis. High-dose BLM also induced dermal fibrosis and increased expression of fibrosis-associated genes ex vivo in human skin, thus confirming and extending the in vivo findings, and demonstrating that a human organ culture model can be used to assess the effect of BLM on skin. In summary, our findings suggest that the BLM pump model is an attractive model to analyze the underlying mechanisms of fibrosis and test the efficacy of potential therapies. However, the choice of mouse strain, duration of BLM administration and dose must be carefully considered when using this model.
NASA Astrophysics Data System (ADS)
Tetreault, J. L.; Buiter, S. J. H.
2012-08-01
Crustal growth at convergent margins can occur by the accretion of future allochthonous terranes (FATs), such as island arcs, oceanic plateaus, submarine ridges, and continental fragments. Using geodynamic numerical experiments, we demonstrate how crustal properties of FATs impact the amount of FAT crust that is accreted or subducted, the type of accretionary process, and the style of deformation on the overriding plate. Our results show that (1) accretion of crustal units occurs when there is a weak detachment layer within the FAT, (2) the depth of detachment controls the amount of crust accreted onto the overriding plate, and (3) lithospheric buoyancy does not prevent FAT subduction during constant convergence. Island arcs, oceanic plateaus, and continental fragments will completely subduct, despite having buoyant lithospheric densities, if they have rheologically strong crusts. Weak basal layers, representing pre-existing weaknesses or detachment layers, will either lead to underplating of faulted blocks of FAT crust to the overriding plate or collision and suturing of an unbroken FAT crust. Our experiments show that the weak, ultramafic layer found at the base of island arcs and oceanic plateaus plays a significant role in terrane accretion. The different types of accretionary processes also affect deformation and uplift patterns in the overriding plate, trench migration and jumping, and the dip of the plate interface. The resulting accreted terranes produced from our numerical experiments resemble observed accreted terranes, such as the Wrangellia Terrane and Klamath Mountain terranes in the North American Cordilleran Belt.
Perirenal fat is related to carotid intima-media thickness in children.
Bassols, J; Martínez-Calcerrada, J-M; Prats-Puig, A; Carreras-Badosa, G; Xargay-Torrent, S; Lizarraga-Mollinedo, E; Feliu-Alsina, M; Riera-Pérez, E; Osiniri, I; de Zegher, F; Ibáñez, L; López-Bermejo, A
2018-04-01
It is well known that increased abdominal fat is associated with cardiovascular (CV) risk. Perirenal fat has been recently associated with CV risk in adults. However, studies with children are lacking. We investigated the relationship of perirenal fat and other abdominal fat depots (including preperitoneal, intra-abdominal and subcutaneous fat) with carotid intima-media thickness (cIMT-a surrogate marker of CV risk) in prepubertal children, so as to identify novel markers that can be easily assessed and used in the early prevention of cardiovascular disease. Subjects were 702 asymptomatic prepubertal Caucasian children (418 lean, 142 overweight and 142 obese) who were recruited in a primary care setting. Ultrasound measurements (perirenal, preperitoneal, intra-abdominal and subcutaneous fat and cIMT), clinical (body mass index (BMI) and systolic blood pressure) and metabolic parameters (insulin resistance (HOMA-IR), high molecular weight (HMW) adiponectin and serum lipids) were assessed. Perirenal fat was associated with diverse metabolic and CV risk factors in all the studied subjects. However, in overweight and obese children, perirenal fat was mostly associated with cIMT (P<0.001) and was the only fat depot that showed independent associations with cIMT in multivariate analyses (overweight chidren: β=0.250, P=0.003, r 2 =12.8%; obese children: β=0.254, P=0.002, r 2 =15.5%) after adjusting for BMI, gender, age and metabolic parameters. Perirenal fat was also the only fat depot that showed independent associations with HMW-adiponectin in obese children (β=-0.263, P=0.006, r 2 =22.8%). Perirenal fat is the main abdominal fat depot associated with cIMT, especially in overweight and obese children, and may thus represent a helpful parameter for assessing CV risk in the pediatric population.
High Dietary Fructose Intake on Cardiovascular Disease Related Parameters in Growing Rats.
Yoo, SooYeon; Ahn, Hyejin; Park, Yoo Kyoung
2016-12-26
The objective of this study was to determine the effects of a high-fructose diet on cardiovascular disease (CVD)-related parameters in growing rats. Three-week-old female Sprague Dawley rats were randomly assigned to four experimental groups; a regular diet group (RD: fed regular diet based on AIN-93G, n = 8), a high-fructose diet group (30Frc: fed regular diet with 30% fructose, n = 8), a high-fat diet group (45Fat: fed regular diet with 45 kcal% fat, n = 8) or a high fructose with high-fat diet group (30Frc + 45Fat, fed diet 30% fructose with 45 kcal% fat, n = 8). After an eight-week treatment period, the body weight, total-fat weight, serum glucose, insulin, lipid profiles and pro-inflammatory cytokines, abdominal aortic wall thickness, and expressions of eNOS and ET-1 mRNA were analyzed. The result showed that total-fat weight was higher in the 30Frc, 45Fat, and 30Frc + 45Fat groups compared to the RD group ( p < 0.05). Serum triglyceride (TG) levels were highest in the 30Frc group than the other groups ( p < 0.05). The abdominal aorta of 30Frc, 45Fat, and 30Frc + 45Fat groups had higher wall thickness than the RD group ( p < 0.05). Abdominal aortic eNOS mRNA level was decreased in 30Frc, 45Fat, and 30Frc + 45Fat groups compared to the RD group ( p < 0.05), and also 45Fat and 30Frc + 45Fat groups had decreased mRNA expression of eNOS compared to the 30Frc group ( p < 0.05). ET-1 mRNA level was higher in 30Frc, 45Fat, and 30Frc + 45Fat groups than the RD group ( p < 0.05). Both high fructose consumption and high fat consumption in growing rats had similar negative effects on CVD-related parameters.
Effects of channel thickness on oxide thin film transistor with double-stacked channel layer
NASA Astrophysics Data System (ADS)
Lee, Kimoon; Kim, Yong-Hoon; Yoon, Sung-Min; Kim, Jiwan; Oh, Min Suk
2017-11-01
To improve the field effect mobility and control the threshold voltage ( V th ) of oxide thin film transistors (TFTs), we fabricated the oxide TFTs with double-stacked channel layers which consist of thick Zn-Sn-O (ZTO) and very thin In-Zn-O (IZO) layers. We investigated the effects of the thickness of thin conductive layer and the conductivity of thick layer on oxide TFTs with doublestacked channel layer. When we changed the thickness of thin conductive IZO channel layer, the resistivity values were changed. This resistivity of thin channel layer affected on the saturation field effect mobility and the off current of TFTs. In case of the thick ZTO channel layer which was deposited by sputtering in Ar: O2 = 10: 1, the device showed better performances than that which was deposited in Ar: O2 = 1: 1. Our TFTs showed high mobility ( μ FE ) of 40.7 cm2/Vs and V th of 4.3 V. We assumed that high mobility and the controlled V th were caused by thin conductive IZO layer and thick stable ZTO layer. Therefore, this double-stacked channel structure can be very promising way to improve the electrical characteristics of various oxide thin film transistors.
NASA Astrophysics Data System (ADS)
Kim, Dae-Yun; Park, Min-Ho; Park, Yong-Keun; Yu, Ji-Sung; Kim, Joo-Sung; Kim, Duck-Ho; Min, Byoung-Chul; Choe, Sug-Bong
2018-02-01
In this study, we investigate the influence of the ferromagnetic layer thickness on the magnetization process. A series of ultrathin Pt/Co/TiO2/Pt films exhibits domain-wall (DW) speed variation of over 100,000 times even under the same magnetic field, depending on the ferromagnetic layer thickness. From the creep-scaling analysis, such significant variation is found to be mainly attributable to the thickness-dependence of the creep-scaling constant in accordance with the creep-scaling theory of the linear proportionality between the creep-scaling constant and the ferromagnetic layer thickness. Therefore, a thinner film shows a faster DW speed. The DW roughness also exhibits sensitive dependence on the ferromagnetic layer thickness: a thinner film shows smoother DW. The present observation provided a guide for an optimal design rule of the ferromagnetic layer thickness for better performance of DW-based devices.
Haschke, F; Popow, C; Schuster, E; Haber, P; Salzer, H P
1984-01-01
We compared body composition (measured by total-body water determination), skinfolds, body circumferences and diameters and the muscle arm area of 10 to 11-year-old boys (n = 21) at the beginning and the end of a 9-months training period (track-and field athletics) with data obtained in 12 control subjects of corresponding ages. Urinary creatinine excretion was measured as a parameter of muscle mass at the end of the training period. Boys engaged in training gained (mean: + 2,6 kg) significantly less (p less than 0,05) weight than controls (mean: + 3,9 kg). Fat-free mass (FFM) as percentage of weight significantly increased in boys engaged in training (mean: + 1,8%; p less than 0,005) at the expense of fat whereas in controls (mean: + 0,6%; p: n.s.) there was no significant change. Decreasing skinfold thickness in boys engaged in training indicated reduction of subcutaneous fat. In controls, subcutaneous fat increased at the trunk and decreased at the periphery. Regression analysis indicated that changes of triceps skinfold thickness did not reflect changes in body fat content (r = 0.30; p: n.s.). A significant relation was established between changes of the subcapular skinfold thickness (r = 0,46; p less than 0,005) and of the sum of 5 skinfolds on the one hand (r = 0,51; p less than 0,005) and the changes of body fat content on the other hand. High standard deviations from the regression lines, however, indicated that accurate prediction of changes in body fat content was not possible in an individual subject.(ABSTRACT TRUNCATED AT 250 WORDS)
Role of Cu layer thickness on the magnetic anisotropy of pulsed electrodeposited Ni/Cu/Ni tri-layer
NASA Astrophysics Data System (ADS)
Dhanapal, K.; Prabhu, D.; Gopalan, R.; Narayanan, V.; Stephen, A.
2017-07-01
The Ni/Cu/Ni tri-layer film with different thickness of Cu layer was deposited using pulsed electrodeposition method. The XRD pattern of all the films show the formation of fcc structure of nickel and copper. This shows the orientated growth in the (2 2 0) plane of the layered films as calculated from the relative intensity ratio. The layer formation in the films were observed from cross sectional view using FE-SEM and confirms the decrease in Cu layer thickness with decreasing deposition time. The magnetic anisotropy behaviour was measured using VSM with two different orientations of layered film. This shows that increasing anisotropy energy with decreasing Cu layer thickness and a maximum of -5.13 × 104 J m-3 is observed for copper deposited for 1 min. From the K eff.t versus t plot, development of perpendicular magnetic anisotropy in the layered system is predicted below 0.38 µm copper layer thickness.
2013-08-01
Sasobit® STA 0+35 cross-section layer thicknesses as constructed............................... 36 Figure 50. Evotherm ™ center-line layer thicknesses...as constructed. ................................................ 37 Figure 51. Evotherm ™ STA 0+15 cross-section layer thicknesses as constructed...37 Figure 52. Evotherm ™ STA 0+25 cross-section layer thicknesses as constructed. .......................... 38 Figure 53
Study of interlayer coupling between FePt and FeCoB thin films through MgO spacer layer
NASA Astrophysics Data System (ADS)
Singh, Sadhana; Kumar, Dileep; Gupta, Mukul; Reddy, V. Raghvendra
2017-05-01
Interlayer exchange coupling between hard-FePt and soft-FeCoB magnetic layers has been studied with increasing thickness of insulator MgO spacer layer in FePt/MgO/FeCoB sandwiched structure. A series of the samples were prepared in identical condition using ion beam sputtering method and characterized for their magnetic and structural properties using magneto-optical Kerr effect (MOKE) and X-ray reflectivity measurements. The nature of coupling between FePt and FeCoB was found to be ferromagnetic which decreases exponentially with increasing thickness of MgO layer. At very low thickness of MgO layer, both layers were found strongly coupled thus exhibiting coherent magnetization reversal. At higher thickness, both layers were found decoupled and magnetization reversal occurred at different switching fields. Strong coupling at very low thickness is attributed to pin holes in MgO layer which lead to direct coupling whereas on increasing thickness, coupling may arise due to magneto-static interactions.
Metaporous layer to overcome the thickness constraint for broadband sound absorption
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Jieun; Lee, Joong Seok; Kim, Yoon Young, E-mail: yykim@snu.ac.kr
The sound absorption of a porous layer is affected by its thickness, especially in a low-frequency range. If a hard-backed porous layer contains periodical arrangements of rigid partitions that are coordinated parallel and perpendicular to the direction of incoming sound waves, the lower bound of the effective sound absorption can be lowered much more and the overall absorption performance enhanced. The consequence of rigid partitioning in a porous layer is to make the first thickness resonance mode in the layer appear at much lower frequencies compared to that in the original homogeneous porous layer with the same thickness. Moreover, appropriatemore » partitioning yields multiple thickness resonances with higher absorption peaks through impedance matching. The physics of the partitioned porous layer, or the metaporous layer, is theoretically investigated in this study.« less
Agarwal, Rajiv; Bills, Jennifer E; Light, Robert P
2010-11-01
Although obesity is associated with poor outcomes, among patients with chronic kidney disease (CKD), obesity is related to improved survival. These results may be related to poor diagnostic performance of body mass index (BMI) in assessing body fat content. Accordingly, among 77 patients with CKD and 20 controls, body fat percentage was estimated by air displacement plethysmography (ADP), skinfold thickness, and body impedance analysis. Defined by BMI ≥30 kg/m(2), the prevalence of obesity was 20% in controls and 65% in patients with CKD. Defined by ADP, the prevalence increased to 60% among controls and to 90% among patients with CKD. Although sensitivity and positive predictive value of BMI to diagnose obesity were 100%, specificity was 72%, but the negative predictive value was only 30%. BMI correctly classified adiposity in 75%. Regardless of the presence or absence of CKD, subclinical obesity (defined as BMI <30 kg/m(2) but excess body fat by ADP) was often missed in people with low lean body mass. The adjusted odds ratio for subclinical obesity per 1 kg of reduced lean body mass by ADP was 1.14 (95% CI: 1.06 to 1.23; P<0.001). Skinfold thickness measurements correctly classified 94% of CKD patients, but bioelectrical impedance analyzer-assessed body fat estimation did so in only 65%. Air displacement plethysmography-, skinfold thickness-, and bioelectrical impedance analyzer-assessed body fat all provided reproducible estimates of adiposity. Skinfold thickness measurements may be a better test to classify obesity among those with CKD. Given the low negative predictive value of BMI for obesity, our study may provide an explanation of the "obesity paradox."
NASA Astrophysics Data System (ADS)
Park, Wug-Dong; Tanioka, Kenkichi
2016-07-01
Amorphous selenium (a-Se) high-gain avalanche rushing amorphous photoconductor (HARP) films have been used for highly sensitive imaging devices. To study a-Se HARP films for a solid-state image sensor, current-voltage, lag, spectral response, and light-transfer characteristics of 0.4-µm-thick a-Se HARP films are investigated. Also, to clarify a suitable Te-doped a-Se layer thickness in the a-Se photoconductor, we considered the effects of Te-doped layer thickness on the lag, spectral response, and light-transfer characteristics of 0.4-µm-thick a-Se HARP films. The threshold field, at which avalanche multiplication occurs in the a-Se HARP targets, decreases when the Te-doped layer thickness increases. The lag of 0.4-µm-thick a-Se HARP targets with Te-doped layers is higher than that of the target without Te doping. The lag of the targets with Te-doped layers is caused by the electrons trapped in the Te-doped layers within the 0.4-µm-thick a-Se HARP films. From the results of the spectral response measurement of about 15 min, the 0.4-µm-thick a-Se HARP targets with Te-doped layers of 90 and 120 nm are observed to be unstable owing to the electrons trapped in the Te-doped a-Se layer. From the light-transfer characteristics of 0.4-µm-thick a-Se HARP targets, as the slope at the operating point of signal current-voltage characteristics in the avalanche mode increases, the γ of the a-Se HARP targets decreases. Considering the effects of dark current on the lag and spectral response characteristics, a Te-doped layer of 60 nm is suitable for 0.4-µm-thick a-Se HARP films.
Liu, Dian; Parker, Helen L; Curcic, Jelena; Kozerke, Sebastian; Steingoetter, Andreas
2016-10-01
Oil-in-water emulsions have recently become of interest to nutritional sciences because of their ability to influence gastrointestinal digestive processes and ultimately benefit human health. MRI offers the potential to noninvasively characterize the interaction between emulsified lipids and gastric secretion within the stomach. We determined noninvasively how emulsion stability modulates volumes of fat and secretion, layering of fat, and the mixing of emulsified fat with secretion within the stomach. This required the development of MRI technology for quantifying fat and secretion concentrations inside the stomach. Twenty-one healthy adults [13 men, mean ± SD age: 22.5 ± 2.5 y, mean ± SD body mass index (in kg/m 2 ): 22.7 ± 1.8] were analyzed in a single-blind, randomized, parallel design. MRI was used to acquire the distributions of fat and secretion in the stomach after ingestion of 2 emulsions: a stable emulsion (E1) or an unstable emulsion (E4) with 20% fat fraction and ∼0.3 mm droplet sizes. Layer, volume, and mixing variables were fitted to the data and compared between the 2 emulsions. The intragastric mixing between fat and secretion was better with the E4 than the E1 [increase in content heterogeneity of 17.1% (95% CI: 12.3%, 21.9%)]. The E4 demonstrated a linear relation [slope 1.57 (95% CI: 0.86, 2.29)] between the degree of layering and mixing. In contrast, no such relation was detected for the E1. Accumulated secretion volume in the stomach was lower with the E4 [decrease in volume variable k s of 2.3 (95% CI: -3.9, -0.7)] and correlated with the degree of layering (r = 0.62, P < 0.001). In healthy adults, intragastric fat layering was influenced mainly by the degree of intragastric mixing, rather than the overall dominance of secretion. The E1 triggered a higher accumulation of gastric secretion, which in turn facilitated homogenization of intragastric content in comparison with its unstable counterpart. This trial was registered at clinicaltrials.gov as NCT02602158. © 2016 American Society for Nutrition.
Relative Translucency of a Multilayered Ultratranslucent Zirconia Material.
Shamseddine, Loubna; Majzoub, Zeina
2017-12-01
The aim of this study was to compare the translucency parameter (TP) of ultratranslucent multilayered (UTML) zirconia according to thickness and layer level. Rectangles of UTML zirconia with four layers [dentin layer (DEL), first transitional layer (FTL), second transitional layer (STL), and enamel layer (ENL)] and four different thicknesses (0.4, 0.6, 0.8, and 1 mm) were milled from blanks. Digital images were taken in a dark studio against white and black backgrounds under simulated daylight illumination and international commission on illumination (CIE) Lab* color values recorded using Photoshop Creative Cloud software. The TP was computed and compared according to thickness and layer level using analysis of variance (ANOVA) followed by Bonferroni post hoc analysis for multiple comparisons. Significance was set at p < 0.05. In each thickness, TP values were similar between any two layers. The significant effect of thickness on the TP was observed only in the first two layers. In the DEL, translucency was significantly greater at 0.4 mm than all other thicknesses. In the FTL, differences were significant between 0.4 and 0.8 mm and between 0.4 and 1 mm. The investigated zirconia does not seem to show gradational changes in relative translucency from dentin to enamel levels regardless of the thickness used. Thickness affected the TP only in the first two layers with better translu-cency at 0.4 mm. Since relative translucency does not seem to be significantly different between layers, clinicians can modify the apicocoronal positioning of the UTML layers within the restoration according to the desired Chroma without any implications on the clinically perceived translucency. While the thickness of 0.4 mm may be suggested for anterior esthetic veneers because of its higher translucency, the other thicknesses of 0.6 to 1 mm can be used to mask colored abutments in full contour restorations.
Non-Uniform Thickness Electroactive Device
NASA Technical Reports Server (NTRS)
Su, Ji (Inventor); Harrison, Joycelyn S. (Inventor)
2006-01-01
An electroactive device comprises at least two layers of material, wherein at least one layer is an electroactive material and wherein at least one layer is of non-uniform thickness. The device can be produced in various sizes, ranging from large structural actuators to microscale or nanoscale devices. The applied voltage to the device in combination with the non-uniform thickness of at least one of the layers (electroactive and/or non-electroactive) controls the contour of the actuated device. The effective electric field is a mathematical function of the local layer thickness. Therefore, the local strain and the local bending/ torsion curvature are also a mathematical function of the local thickness. Hence the thinnest portion of the actuator offers the largest bending and/or torsion response. Tailoring of the layer thicknesses can enable complex motions to be achieved.
Study of ion beam sputtered Fe/Si interfaces as a function of Si layer thickness
NASA Astrophysics Data System (ADS)
Kumar, Anil; Brajpuriya, Ranjeet; Singh, Priti
2018-01-01
The exchange interaction in metal/semiconductor interfaces is far from being completely understood. Therefore, in this paper, we have investigated the nature of silicon on the Fe interface in the ion beam deposited Fe/Si/Fe trilayers keeping the thickness of the Fe layers fixed at 3 nm and varying the thickness of the silicon sandwich layer from 1.5 nm to 4 nm. Grazing incidence x-ray diffraction and atomic force microscopy techniques were used, respectively, to study the structural and morphological changes in the deposited films as a function of layer thickness. The structural studies show silicide formation at the interfaces during deposition and better crystalline structure of Fe layers at a lower spacer layer thickness. The magnetization behavior was investigated using magneto-optical Kerr effect, which clearly shows that coupling between the ferromagnetic layers is highly influenced by the semiconductor spacer layer thickness. A strong antiferromagnetic coupling was observed for a value of tSi = 2.5 nm but above this value an unexpected behavior of hysteresis loop (step like) with two coercivity values is recorded. For spacer layer thickness greater than 2.5 nm, an elemental amorphous Si layer starts to appear in the spacer layer in addition to the silicide layer at the interfaces. It is observed that in the trilayer structure, Fe layers consist of various stacks, viz., Si doped Fe layers, ferromagnetic silicide layer, and nonmagnetic silicide layer at the interfaces. The two phase hysteresis loop is explained on the basis of magnetization reversal of two ferromagnetic layers, independent of each other, with different coercivities. X-ray photo electron spectroscopy technique was also used to study interfaces characteristics as a function of tSi.
Reeds, Dominic N.; Mohammed, B. Selma; Klein, Samuel; Boswell, Craig Brian
2013-01-01
Background: Phosphatidylcholine and deoxycholate (PC-DC) injections are a popular nonsurgical method to eliminate unwanted fat. The safety and efficacy of this approach is uncertain. Objective: The authors evaluate the effects of PC-DC treatments on body composition, adipocyte function, and mechanisms responsible for fat loss. Methods: This randomized, open-label study enrolled 13 women with a body mass index (BMI) ≤30 kg/m2 and lower abdominal subcutaneous fat suitable for small-volume liposuction. Patients were randomized by the final digit of their Social Security numbers and received between 2 and 4 PC-DC treatments, spaced 8 weeks apart. One side below the umbilicus was injected with PC-DC. The contralateral, control side received no treatment. Adipose tissue biopsies were performed on the treated side at baseline, 1 week after the first treatment, and 8 weeks after the final treatment. The primary outcome was change in adipose tissue thickness at baseline and 8 weeks after the final treatment. Results: Seven women completed the study. Treatment with PC-DC significantly reduced the thickness of the anterior subcutaneous abdominal fat (P = .004). Adipose tissue showed rapid increases in crown-like structures, macrophage infiltration, and reduced expression of leptin, hormone-sensitive lipase, adipose tissue triglyceride lipase, and CD36. Plasma C-reactive protein, lipid profile, and plasma glucose concentrations were unchanged. Conclusions: PC-DC injections can effectively reduce abdominal fat volume and thickness by inducing adipocyte necrosis. These treatments do not appear to increase circulating markers of inflammation or affect glucose and lipid metabolism. Level of Evidence: 3 PMID:23439063
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunter, David M.; Belev, Gueorgi; DeCrescenzo, Giovanni
2007-08-15
Blocking layers are used to reduce leakage current in amorphous selenium detectors. The effect of the thickness of the blocking layer on the presampling modulation transfer function (MTF) and on dark current was experimentally determined in prototype single-line CCD-based amorphous selenium (a-Se) x-ray detectors. The sampling pitch of the detectors evaluated was 25 {mu}m and the blocking layer thicknesses varied from 1 to 51 {mu}m. The blocking layers resided on the signal collection electrodes which, in this configuration, were used to collect electrons. The combined thickness of the blocking layer and a-Se bulk in each detector was {approx}200 {mu}m. Asmore » expected, the dark current increased monotonically as the thickness of the blocking layer was decreased. It was found that if the blocking layer thickness was small compared to the sampling pitch, it caused a negligible reduction in MTF. However, the MTF was observed to decrease dramatically at spatial frequencies near the Nyquist frequency as the blocking layer thickness approached or exceeded the electrode sampling pitch. This observed reduction in MTF is shown to be consistent with predictions of an electrostatic model wherein the image charge from the a-Se is trapped at a characteristic depth within the blocking layer, generally near the interface between the blocking layer and the a-Se bulk.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snel, J.; Monclús, M. A.; Castillo-Rodríguez, M.
The mechanical properties and deformation mechanisms of Cu/Nb nanoscale metallic multilayers (NMMs) manufactured by accumulative roll bonding are studied at 25°C and 400°C. Cu/Nb NMMs with individual layer thicknesses between 7 nm and 63 nm were tested by in situ micropillar compression inside a scanning electron microscope. Yield strength, strain-rate sensitivities and activation volumes were obtained from the pillar compression tests. The deformed micropillars were examined under scanning and transmission electron microscopy in order to examine the deformation mechanisms active for different layer thicknesses and temperatures. The paper suggests that room temperature deformation was determined by dislocation glide at largermore » layer thicknesses and interface-related mechanisms at the thinner layer thicknesses. The high-temperature compression tests, in contrast, revealed superior thermo-mechanical stability and strength retention for the NMMs with larger layer thicknesses with deformation controlled by dislocation glide. A remarkable transition in deformation mechanism occurred as the layer thickness decreased, to a deformation response controlled by diffusion processes along the interfaces, which resulted in temperature-induced softening. Finally, a deformation mechanism map, in terms of layer thickness and temperature, is proposed from the results obtained in this investigation.« less
Snel, J.; Monclús, M. A.; Castillo-Rodríguez, M.; ...
2017-08-29
The mechanical properties and deformation mechanisms of Cu/Nb nanoscale metallic multilayers (NMMs) manufactured by accumulative roll bonding are studied at 25°C and 400°C. Cu/Nb NMMs with individual layer thicknesses between 7 nm and 63 nm were tested by in situ micropillar compression inside a scanning electron microscope. Yield strength, strain-rate sensitivities and activation volumes were obtained from the pillar compression tests. The deformed micropillars were examined under scanning and transmission electron microscopy in order to examine the deformation mechanisms active for different layer thicknesses and temperatures. The paper suggests that room temperature deformation was determined by dislocation glide at largermore » layer thicknesses and interface-related mechanisms at the thinner layer thicknesses. The high-temperature compression tests, in contrast, revealed superior thermo-mechanical stability and strength retention for the NMMs with larger layer thicknesses with deformation controlled by dislocation glide. A remarkable transition in deformation mechanism occurred as the layer thickness decreased, to a deformation response controlled by diffusion processes along the interfaces, which resulted in temperature-induced softening. Finally, a deformation mechanism map, in terms of layer thickness and temperature, is proposed from the results obtained in this investigation.« less
Electrophoretic deposition of bi-layered LSM/LSM-YSZ cathodes for solid oxide fuel cell
NASA Astrophysics Data System (ADS)
Itagaki, Yoshiteru; Watanabe, Shinji; Yamaji, Tsuyoshi; Asamoto, Makiko; Yahiro, Hidenori; Sadaoka, Yoshihiko
2012-09-01
Bi-layered cathodes with the LSM/LSM-YSZ structure for solid oxide fuel cells were successfully formed on the carbon-sputtered surface of a YSZ sheet by electrophoretic deposition (EPD). The thicknesses of the first layer of LSM-YSZ (LY) and the second layer of La0.8Sr0.2MnO3 (LSM) could be controlled by adjusting the deposition time in the EPD process. The cathodic properties of the bi-layered structures were superior to those of the mono-layered structures, and were dependent on the thickness of each layer. Decreasing the thickness of the first layer and increasing that of the second layer tended to reduce both polarization and ohmic resistances. The optimal thickness of the first layer at the operating temperature of 600 °C was 4 μm, suggesting that an effective three-phase boundary was extended from the interface between the electrolyte and cathode film to around 4 μm thickness.
Adaptive sound speed correction for abdominal ultrasonography: preliminary results
NASA Astrophysics Data System (ADS)
Jin, Sungmin; Kang, Jeeun; Song, Tai-Kyung; Yoo, Yangmo
2013-03-01
Ultrasonography has been conducting a critical role in assessing abdominal disorders due to its noninvasive, real-time, low cost, and deep penetrating capabilities. However, for imaging obese patients with a thick fat layer, it is challenging to achieve appropriate image quality with a conventional beamforming (CON) method due to phase aberration caused by the difference between sound speeds (e.g., 1580 and 1450m/s for liver and fat, respectively). For this, various sound speed correction (SSC) methods that estimate the accumulated sound speed for a region-of interest (ROI) have been previously proposed. However, with the SSC methods, the improvement in image quality was limited only for a specific depth of ROI. In this paper, we present the adaptive sound speed correction (ASSC) method, which can enhance the image quality for whole depths by using estimated sound speeds from two different depths in the lower layer. Since these accumulated sound speeds contain the respective contributions of layers, an optimal sound speed for each depth can be estimated by solving contribution equations. To evaluate the proposed method, the phantom study was conducted with pre-beamformed radio-frequency (RF) data acquired with a SonixTouch research package (Ultrasonix Corp., Canada) with linear and convex probes from the gel pad-stacked tissue mimicking phantom (Parker Lab. Inc., USA and Model539, ATS, USA) whose sound speeds are 1610 and 1450m/s, respectively. From the study, compared to the CON and SSC methods, the ASSC method showed the improved spatial resolution and information entropy contrast (IEC) for convex and linear array transducers, respectively. These results indicate that the ASSC method can be applied for enhancing image quality when imaging obese patients in abdominal ultrasonography.
Role of Beam Spot Size in Heating Targets at Depth.
Ross, E Victor; Childs, James
2015-12-01
Wavelength, fluence and pulse width are primary device parameters for the treatment of skin and hair conditions. Wavelength selection is based on tissue scatter and target chromophores. Pulse width is chosen to optimize target heating. Energy absorbed by a target is determined by fluence and spot size of the light source as well as the depth of the target. We conducted an in vitro skin study and simulations to compare heating of a target at a particular depth versus spot size. Porcine skin and fat tissue were prepared and separated to form a 2mm skin layer above a 1 cm thick fat layer. A 50 μm thermocouple was placed between the layers and centered beneath a 23 x 38 mm treatment window of an 805 nm diode laser device (Vectus, Cynosure, Westford, MA). Apertures provided various incident beam spot sizes and the temperature rise of the thermocouple was measured for a fixed fluence. The 2mm deep target's temperature rise versus treatment area showed two regimes with different positive slopes. The first regime up to approximately 1 cm(2) area has a greater temperature rise versus area than that for the regime greater than 1 cm(2). The slope in the second regime is nonetheless appreciable and provides a fluence reduction factor for skin safety. The same temperature rise in a target at 2 mm depth (typical hair bulb depth in some areas) is realized by increasing the area from 1 to 4 cm(2) while reducing the fluence by half. The role of spot size and in situ beam divergence is an important consideration to determine optimum fluence settings that increase skin safety when treating deeper targets.
Takahara, Taro; Imai, Yutaka; Yamashita, Tomohiro; Yasuda, Seiei; Nasu, Seiji; Van Cauteren, Marc
2004-01-01
To examine a new way of body diffusion weighted imaging (DWI) using the short TI inversion recovery-echo planar imaging (STIR-EPI) sequence and free breathing scanning (diffusion weighted whole body imaging with background body signal suppression; DWIBS) to obtain three-dimensional displays. 1) Apparent contrast-to-noise ratios (AppCNR) between lymph nodes and surrounding fat tissue were compared in three types of DWI with and without breath-holding, with variable lengths of scan time and slice thickness. 2) The STIR-EPI sequence and spin echo-echo planar imaging (SE-EPI) sequence with chemical shift selective (CHESS) pulse were compared in terms of their degree of fat suppression. 3) Eleven patients with neck, chest, and abdominal malignancy were scanned with DWIBS for evaluation of feasibility. Whole body imaging was done in a later stage of the study using the peripheral vascular coil. The AppCNR of 8 mm slice thickness images reconstructed from 4 mm slice thickness source images obtained in a free breathing scan of 430 sec were much better than 9 mm slice thickness breath-hold scans obtained in 25 sec. High resolution multi-planar reformat (MPR) and maximum intensity projection (MIP) images could be made from the data set of 4 mm slice thickness images. Fat suppression was much better in the STIR-EPI sequence than SE-EPI with CHESS pulse. The feasibility of DWIBS was showed in clinical scans of 11 patients. Whole body images were successfully obtained with adequate fat suppression. Three-dimensional DWIBS can be obtained with this technique, which may allow us to screen for malignancies in the whole body.
NASA Astrophysics Data System (ADS)
Sun, R. X.; Zheng, J.; Liao, X. L.; Che, T.; Gou, Y. F.; He, D. B.; Deng, Z. G.
2014-10-01
A double-layer high-temperature superconductor (HTSC) arrangement was proposed and proved to be able to bring improvements to both levitation force and guidance force compared with present single-layer HTSC arrangement. To fully exploit the applied magnetic field by a magnetic rail, the thickness dependence of a double-layer HTSC arrangement on the levitation performance was further investigated in the paper. In this study, the lower-layer bulk was polished step by step to different thicknesses, and the upper-layer bulk with constant thickness was directly superimposed on the lower-layer one. The levitation force and the force relaxation of the double-layer HTSC arrangement were measured above a Halbach magnetic rail. Experimental result shows that a bigger levitation force and a less levitation force decay could be achieved by optimizing the thickness of the lower-layer bulk HTSC. This thickness optimization method could be applied together with former reported double-layer HTSC arrangement method with aligned growth sector boundaries pattern. This series of study on the optimized combination method do bring a significant improvement on the levitation performance of present HTS maglev systems.
USDA-ARS?s Scientific Manuscript database
Backfat thickness affects preservation of the beef carcass after slaughter and confers organoleptic characteristics assessed by the consumer. One of the breeding goals for Canchim, a tropically adapted breed, is to comprehensively increase fat thickness. Our goal was to identify genomic regions ass...
Cao, Jay J; Gregoire, Brian R
2016-04-01
Bone health is influenced by body mass and estrogen. The objective of the study was to determine whether high-fat diet-induced obesity affects bone structure and alters markers of bone turnover in ovariectomized (OVX) mice. We hypothesized that a high-fat diet would increase body weight gain and serum estradiol levels in OVX mice but would not improve bone structural parameter in OVX mice. Thirty-five C57BL/6 mice were either sham operated or OVX at the age of 4 months and then fed either a normal-fat diet (10% energy as fat) or a high-fat diet (45% energy as fat with extra fat from lard) ad libitum for 11 weeks. Ovariectomy increased body weight, serum tartrate-resistant acid phosphatase concentration, and expression of cathepsin K in bone; decreased serum estradiol concentration; and induced significant bone loss manifested by decreased bone volume/total volume (BV/TV), connectivity density (Conn.D), trabecular number, and trabecular thickness with increased trabecular separation and structural model index (P < .01). The high-fat diet increased body weight (P < .01) in OVX mice and nonsignificantly decreased BV/TV (P = .08) and Conn.D (P = .10). Despite having similar serum estradiol concentrations and higher body weight, OVX mice consuming the high-fat diet had lower BV/TV, Conn.D, trabecular number, trabecular thickness, and higher structural model index and trabecular separation than did sham mice fed the normal-fat diet. These findings indicate that increased body weight and elevated serum estradiol concentration induced by a high-fat diet do not mitigate ovariectomy-induced bone loss in mice. Published by Elsevier Inc.
Effect of layer thickness on the properties of nickel thermal sprayed steel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nurisna, Zuhri, E-mail: zuhri-nurisna@yahoo.co.id; Triyono,, E-mail: triyonomesin@uns.ac.id; Muhayat, Nurul, E-mail: nurulmuhayat@staff.uns.ac.id
Thermal arc spray nickel coating is widely used for decorative and functional applications, by improving corrosion resistance, wear resistance, heat resistence or by modifying other properties of the coated materials. There are several properties have been studied. Layer thickness of nickel thermal sprayed steel may be make harder the substrate surface. In this study, the effect of layer thickness of nickel thermal sprayed steel has been investigated. The rectangular substrate specimens were coated by Ni–5 wt.% Al using wire arc spray method. The thickness of coating layers were in range from 0.4 to 1.0 mm. Different thickness of coating layers weremore » conducted to investigate their effect on hardness and morphology. The coating layer was examined by using microvickers and scanning electron microscope with EDX attachment. Generally, the hardness at the interface increased with increasing thickness of coating layers for all specimens due to higher heat input during spraying process. Morphology analysis result that during spraying process aluminum would react with surrounding oxygen and form aluminum oxide at outer surface of splat. Moreover, porosity was formed in coating layers. However, presence porosity is not related to thickness of coating material. The thicker coating layer resulted highesr of hardness and bond strength.« less
Predoi, Mihai Valentin; Ech Cherif El Kettani, Mounsif; Leduc, Damien; Pareige, Pascal; Coné, Khadidiatou
2015-08-01
The capability of shear horizontal (SH) guided waves, to evaluate geometrical imperfections in a bonding layer, is investigated. SH waves are used in a three-layer structure in which the adhesive layer has variable thickness. It is proven that the SH waves are adapting to the local thickness of the adhesive layer (adiabatic waves). This is particularly useful in case of small thickness variations, which is of technical interest. The influence of thickness and stiffness of the adhesive layer on the wavenumbers are investigated. The selected SH2 mode is proven to be very sensitive to the adhesive layer thickness variation in the given frequency range and considerably less sensitive to the adhesive stiffness variation. This property is due to its specific displacement field and is important in practical applications, such as inspection techniques based on SH waves, in order to avoid false alarms.
NASA Astrophysics Data System (ADS)
Assis, Anu; Shahul Hameed T., A.; Predeep, P.
2017-06-01
Mobility and current handling capabilities of Organic Field Effect Transistor (OFET) are vitally important parameters in the electrical performance where the material parameters and thickness of different layers play significant role. In this paper, we report the simulation of an OFET using multi physics tool, where the active layer is pentacene and Poly Methyl Methacrylate (PMMA) forms the dielectric. Electrical characterizations of the OFET on varying the thickness of the dielectric layer from 600nm to 400nm are simulated and drain current, transconductance and mobility are analyzed. In the study it is found that even though capacitance increases with reduction in dielectric layer thickness, the transconductance effect is reflected many more times in the mobility which in turn could be attributed to the variations in transverse electric field. The layer thickness below 300nm may result in gate leakage current points to the requirement of optimizing the thickness of different layers for better performance.
Feed value of supplemental fats used in feedlot cattle diets.
Zinn, Richard Avery; Jorquera, Alejandro Plascencia
2007-07-01
The inclusion of supplemental fats in growing-finishing diets for feedlot cattle also improves diet "condition." Quality factors that may influence the feeding value of fat include the source of fat; moisture, impurities, and unsaponifiables; free fatty acid concentration; degree of saturation or titer; and rancidity (peroxide value). The net energy value of fat declines linearly with an increasing level of supplementation because of constraints on postruminal fatty acid digestion. The authors recommend that receiving diets not contain more than 2% supplemental fat. Little evidence suggests that the feeding value of fat is different for Holsteins than for conventional beef breeds. Fat supplementation is not consistent in its effect on intramuscular fat distribution (marbling), longissimus (rib eye) area, and fat thickness, but can be expected to increase dressing percentage and kidney, pelvic, and heart fat percentage.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xiaoyu, E-mail: xiaoyu.yang@wdc.com; Chen, Lifan; Han, Hongmei
The impact of the fluorine-based reactive ion etch (RIE) process on the structural, electrical, and magnetic properties of NiFe and CoNiFe-plated materials was investigated. Several techniques, including X-ray fluorescence, 4-point-probe, BH looper, transmission electron microscopy (TEM), and electron energy loss spectroscopy (EELS), were utilized to characterize both bulk film properties such as thickness, average composition, Rs, ρ, Bs, Ms, and surface magnetic “dead” layers' properties such as thickness and element concentration. Experimental data showed that the majority of Rs and Bs changes of these bulk films were due to thickness reduction during exposure to the RIE process. ρ and Msmore » change after taking thickness reduction into account were negligible. The composition of the bulk films, which were not sensitive to surface magnetic dead layers with nano-meter scale, showed minimum change as well. It was found by TEM and EELS analysis that although both before and after RIE there were magnetic dead layers on the top surface of these materials, the thickness and element concentration of the layers were quite different. Prior to RIE, dead layer was actually native oxidation layers (about 2 nm thick), while after RIE dead layer consisted of two sub-layers that were about 6 nm thick in total. Sub-layer on the top was native oxidation layer, while the bottom layer was RIE “damaged” layer with very high fluorine concentration. Two in-situ RIE approaches were also proposed and tested to remove such damaged sub-layers.« less
Applying a uniform layer of disinfectant by wiping.
Cooper, D W
2000-01-01
Disinfection or sterilization often requires applying a film of liquid to a surface, frequently done by using a wiper as the applicator. The wiper must not only hold a convenient amount of liquid, it must deposit it readily and uniformly. Contact time is critical to disinfection efficacy. Evaporation can limit the contact time. To lengthen the contact time, thickly applied layers are generally preferred. The thickness of such layers can be determined by using dyes or other tracers, as long as the tracers do not significantly affect the liquid's surface tension and viscosity and thus do not affect the thickness of the applied layer. Alternatively, as done here, the thickness of the layer can be inferred from the weight loss of the wiper. Results are reported of experiments on thickness of the layers applied under various conditions. Near saturation, hydrophilic polyurethane foam wipers gave layers roughly 10 microns thick, somewhat less than expected from hydrodynamic theory, but more than knitted polyester or woven cotton. Wipers with large liquid holding capacity, refilled often, should produce more nearly uniform layers. Higher pressures increase saturation in the wiper, tending to thicken the layer, but higher pressures also force liquid from the interface, tending to thin the layer, so the net result could be thicker or thinner layers, and there is likely to be an optimal pressure.
NASA Astrophysics Data System (ADS)
Kumar, Rajeev; Kushwaha, Angad S.; Srivastava, Monika; Mishra, H.; Srivastava, S. K.
2018-03-01
In the present communication, a highly sensitive surface plasmon resonance (SPR) biosensor with Kretschmann configuration having alternate layers, prism/zinc oxide/silver/gold/graphene/biomolecules (ss-DNA) is presented. The optimization of the proposed configuration has been accomplished by keeping the constant thickness of zinc oxide (32 nm), silver (32 nm), graphene (0.34 nm) layer and biomolecules (100 nm) for different values of gold layer thickness (1, 3 and 5 nm). The sensitivity of the proposed SPR biosensor has been demonstrated for a number of design parameters such as gold layer thickness, number of graphene layer, refractive index of biomolecules and the thickness of biomolecules layer. SPR biosensor with optimized geometry has greater sensitivity (66 deg/RIU) than the conventional (52 deg/RIU) as well as other graphene-based (53.2 deg/RIU) SPR biosensor. The effect of zinc oxide layer thickness on the sensitivity of SPR biosensor has also been analysed. From the analysis, it is found that the sensitivity increases significantly by increasing the thickness of zinc oxide layer. It means zinc oxide intermediate layer plays an important role to improve the sensitivity of the biosensor. The sensitivity of SPR biosensor also increases by increasing the number of graphene layer (upto nine layer).
Photovoltaic device having light transmitting electrically conductive stacked films
Weber, Michael F.; Tran, Nang T.; Jeffrey, Frank R.; Gilbert, James R.; Aspen, Frank E.
1990-07-10
A light transmitting electrically conductive stacked film, useful as a light transmitting electrode, including a first light transmitting electrically conductive layer, having a first optical thickness, a second light transmitting layer, having a second optical thickness different from the optical thickness of the first layer, and an electrically conductive metallic layer interposed between and in initimate contact with the first and second layers.
Prospective Controlled Study of Buttock Fat Transfer Using Ultrasound and Photographic Measurements
2016-01-01
Background: Buttock fat transfer is now the preferred method for gluteal augmentation. However, its efficacy has not been well-documented using measurements. Methods: Twenty-five consecutive patients underwent buttock fat transfer performed by the author. Twenty-one patients returned for measurements ≥3 months after surgery (inclusion rate, 84%). A separate group of 25 patients undergoing cosmetic surgery without buttock fat transfer served as controls. All patients underwent superwet liposuction using total intravenous anesthesia and no prone positioning. A closed filtration system was used to collect the fat. Subcutaneous fat thickness was assessed using ultrasound imaging. Measurements were made on standardized photographs. The data were controlled for change in body mass index. Clinical data were also evaluated. Results: The mean fat volume injected per buttock was 287 mL (range, 70–550 mL). Ultrasound measurements detected a significant increase in the subcutaneous fat thickness (P ≤ 0.001), with mean increments of 0.66 cm for the right buttock and 0.86 cm for the left buttock and no significant change for control patients. The mean calculated fat retention, based on the measured surface area injected, was 66%. Photographic measurements of buttock projection revealed a significant increase in treated patients (P < 0.01) and no significant change in control patients. There were no clinical complications at either recipient or donor sites and no evidence of oily cysts on ultrasound examinations. Conclusions: Photographic and ultrasound measurements, and clinical findings, confirm that buttock fat transfer effectively and safely increases buttock projection. PMID:27579222
Caucasian children's fat mass: routine anthropometry v. air-displacement plethysmography.
Michels, Nathalie; Huybrechts, Inge; Bammann, Karin; Lissner, Lauren; Moreno, Luis; Peeters, Maarten; Sioen, Isabelle; Vanaelst, Barbara; Vyncke, Krishna; De Henauw, Stefaan
2013-04-28
The present paper will use fat mass percentage (FM%) obtained via BOD POD® air-displacement plethysmography (FMADP%) to examine the relative validity of (1) anthropometric measurements/indices and (2) of FM% assessed with equations (FMeq%) based on skinfold thickness and bioelectrical impedance (BIA). In 480 Belgian children (aged 5-11 years) weight, height, skinfold thickness (triceps and subscapular), body circumferences (mid-upper arm, waist and hip), foot-to-foot BIA (Tanita®) and FMADP% were measured. Anthropometric measurements and calculated indices were compared with FMADP%. Next, published equations were used to calculate FMeq% using impedance (equations of Tanita®, Tyrrell, Shaefer and Deurenberg) or skinfold thickness (equations of Slaughter, Goran, Dezenberg and Deurenberg). Both indices and equations performed better in girls than in boys. For both sexes, the sum of skinfold thicknesses resulted in the highest correlation with FMADP%, followed by triceps skinfold, arm fat area and subscapular skinfold. In general, comparing FMeq% with FMADP% indicated mostly an age and sex effect, and an increasing underestimation but less dispersion with increasing FM%. The Tanita® impedance equation and the Deurenberg skinfold equation performed the best, although none of the used equations were interchangeable with FMADP%. In conclusion, the sum of triceps and subscapular skinfold thickness is recommended as marker of FM% in the absence of specialised technologies. Nevertheless, the higher workload, cost and survey management of an immobile device like the BOD POD® remains justified.
Layer-by-layer-based silica encapsulation of individual yeast with thickness control.
Lee, Hojae; Hong, Daewha; Choi, Ji Yu; Kim, Ji Yup; Lee, Sang Hee; Kim, Ho Min; Yang, Sung Ho; Choi, Insung S
2015-01-01
In the area of cell-surface engineering with nanomaterials, the metabolic and functional activities of the encapsulated cells are manipulated and controlled by various parameters of the artificial shells that encase the cells, such as stiffness and elasticity, thickness, and porosity. The mechanical durability and physicochemical stability of inorganic shells prove superior to layer-by-layer-based organic shells with regard to cytoprotection, but it has been difficult to vary the parameters of inorganic shells including their thickness. In this work, we combine the layer-by-layer technique with a process of bioinspired silicification to control the thickness of the silica shells that encapsulate yeast Saccharomyces cerevisiae cells individually, and investigate the thickness-dependent microbial growth. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Chiral photonic crystals with an anisotropic defect layer.
Gevorgyan, A H; Harutyunyan, M Z
2007-09-01
In the present paper we consider some properties of defect modes in chiral photonic crystals with an anisotropic defect layer. We solved the problem by Ambartsumian's layer addition method. We investigated the influence of the defect layer thickness variation and its location in the chiral photonic crystal (CPC) and also its optical axes orientation, as well as of CPC thickness variation on defect mode properties. Variations of the optical thickness of the defect layer have its impact on the defect mode linewidth and the light accumulation in the defect. We obtain that CPCs lose their base property at certain defect layer thicknesses; namely, they lose their diffraction reflection dependence on light polarization. We also show that the circular polarization handedness changes from right-handed to left-handed if the defect layer location is changed, and therefore, such systems can be used to create sources of elliptically polarized light with tunable ellipticity. Some nonreciprocity properties of such systems are investigated, too. In particular, it is also shown that such a system can work as a practically ideal wide band optical diode for circularly polarized incident light provided the defect layer thickness is properly chosen, and it can work as a narrow band diode at small defect layer thicknesses.
Kee, Changwon; Cho, Changhwan
2003-06-01
The authors investigated the correlation between visual field defects detected by automated perimetry and the thickness of the retinal nerve fiber layer measured with optical coherence tomography, and examined whether there is a decrease in retinal nerve fiber layer thickness in the apparently normal hemifield of glaucomatous eyes. Forty-one patients with glaucoma and 41 normal control subjects were included in this study. Statistical correlations between the sum of the total deviation of 37 stimuli of each hemifield and the ratio of decrease in retinal nerve fiber layer thickness were evaluated. The statistical difference between the retinal nerve fiber layer thickness of the apparently normal hemifield in glaucomatous eyes and that of the corresponding hemifield in normal subjects was also evaluated. There was a statistically significant correlation in the sum of the total deviation and retinal nerve fiber layer thickness decrease ratio (superior hemifield, P = 0.001; inferior hemifield, P = 0.003). There was no significant decrease in retinal nerve fiber layer thickness in the area that corresponded to the normal visual field in the hemifield defect with respect to the horizontal meridian in glaucomatous eyes (superior side, P = 0.148; inferior side, P = 0.341). Optical coherence tomography was capable of demonstrating and measuring retinal nerve fiber layer abnormalities. No changes in the retinal nerve fiber layer thickness of the apparently normal hemifield were observed in glaucomatous eyes.
Cunault, C; Coquinot, Y; Burton, C H; Picard, S; Pourcher, A M
2013-03-15
The structure and composition of the fouling deposits caused by pig slurry heated in a tubular heat exchanger were characterized to understand their formation and thus be able to minimize fouling and define effective routine cleaning methods. Two temperatures (55 °C and 80 °C) were investigated. Two types of fouling were identified: organic/mineral and biofilm. The first only formed at temperatures above 50 °C, often during the heating phase, and was the main problem encountered in treatments at 80 °C. Organic/mineral deposits formed a thin compact sub-layer and a thick porous top layer composed of 67-76% minerals, 9-15% proteins, 8-20% carbohydrates and 0-5% fats. Biofilms formed at temperatures between 25 °C and 70 °C in both the cooling and heating sections of the exchanger. This type of fouling predominated at temperatures below 55 °C. The biofilm covered a thin mineral base layer. Strongly acidic or alkaline washing cycle are recommended to clean Type I deposits, while in-line gas-rumbling is recommended for Type II fouling. Copyright © 2013 Elsevier Ltd. All rights reserved.
Efficient methylammonium lead iodide perovskite solar cells with active layers from 300 to 900 nm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Momblona, C.; Malinkiewicz, O.; Soriano, A.
2014-08-01
Efficient methylammonium lead iodide perovskite-based solar cells have been prepared in which the perovskite layer is sandwiched in between two organic charge transporting layers that block holes and electrons, respectively. This configuration leads to stable and reproducible devices that do not suffer from strong hysteresis effects and when optimized lead to efficiencies close to 15%. The perovskite layer is formed by using a dual-source thermal evaporation method, whereas the organic layers are processed from solution. The dual-source thermal evaporation method leads to smooth films and allows for high precision thickness variations. Devices were prepared with perovskite layer thicknesses ranging frommore » 160 to 900 nm. The short-circuit current observed for these devices increased with increasing perovskite layer thickness. The main parameter that decreases with increasing perovskite layer thickness is the fill factor and as a result optimum device performance is obtained for perovskite layer thickness around 300 nm. However, here we demonstrate that with a slightly oxidized electron blocking layer the fill factor for the solar cells with a perovskite layer thickness of 900 nm increases to the same values as for the devices with thin perovskite layers. As a result the power conversion efficiencies for the cells with 300 and 900 nm are very similar, 12.7% and 12%, respectively.« less
Dittus, Wolfgang P J; Gunathilake, K A Sunil
2015-06-01
Skinfold thickness (SFT) has been used often in non-human primates and humans as a proxy to estimate fatness (% body fat). We intended to validate the relation between SFT (in recently deceased specimens) and the mass of adipose tissue as determined from dissection of fresh carcasses of wild toque macaques (Macaca sinica). In adult male and female toque macaques body composition is normally 2% adipose tissue. Calipers for measuring SFT were suitable for measuring only some subcutaneous deposits of adipose tissue but were not suitable for measuring large fat deposits within the body cavity or minor intermuscular ones. The anatomical distribution of 13 different adipose deposits, in different body regions (subcutaneous, intra-abdominal and intermuscular) and their proportional size differences, were consistent in this species (as in other primates), though varying in total mass among individuals. These consistent allometric relationships were fundamental for estimating fatness of different body regions based on SFT. The best fit statistically significant correlations and regressions with the known masses of dissectible adipose tissue were evident between the SFT means of the seven sites measured, as well as with a single point on the abdomen anterior to the umbilicus. SFT related to total fat mass and intra-abdominal fat mass in curvilinear regressions and to subcutaneous fat mass in a linear relationship. To adjust for differences in body size among individuals, and to circumvent intangible variations in total body mass allocated, for example to the gastro-intestinal contents, dissected fat mass was estimated per unit body size (length of crown-rump)(3). SFT had greater coefficients of correlation and regressions with this Fat Mass Index (g/dm(3)) than with Percent Body Fat. © 2015 Wiley Periodicals, Inc.
Bashir, Muhammad Mustehsan; Sohail, Muhammad; Bashir, Afzaal; Khan, Farid Ahmad; Jan, Sadia Nosheen; Imran, Muhammad; Ahmad, Fridoon Jawad; Choudhery, Mahmood S
2018-02-23
To evaluate the outcomes of conventional fat grafting for facial contour deformities and to describe clinical outcome of a patient with contour deformity of face treated with ex vivo expanded adipose tissue-derived mesenchymal stem cells (ASCs) enriched fat graft. The Department of Plastic Surgery and Tissue Engineering and Regenerative Medicine Laboratory, King Edward Medical University/Mayo Hospital, Lahore, from September 2015 to September 2017. Patients with contour deformities of face requiring soft tissue augmentation were included. Fat was harvested, processed, and injected following a standard protocol. Both subjective and objective assessments were performed and complications were also noted. Twenty-five patients underwent 51 fat-grafting sessions over a period of 24 months. Eighteen (72%) patients underwent multiple fat-grafting sessions. Mean (standard deviation) soft tissue thickness after 72 hours and 6 months of first fat graft session was 18.62 (7.2) and 12.88 (6.21) mm, respectively, which corresponds to 30.77 (13)% reduction of transplanted fat. Physician and patient assessment scores were 3.42 (0.92) and 4 (1.04), respectively. Few minor complications were observed. In the patient undergoing ex vivo expanded ASCs enriched fat graft, there was minimal decrease in soft tissue thickness of treated area (44 mm vs 42 mm) 6 months postoperatively and patient was highly satisfied with the outcome after the single session. Conventional fat grafting is safe for correction of facial contour deformities. However, procedure needs to be repeated multiple times to produce satisfactory results. Beneficial effects of ex vivo expanded ASCs enriched fat grafting have a potential to alter the current treatment paradigm of fat grafting for soft tissue reconstruction.
Single and combined effects of body composition phenotypes on carotid intima-media thickness.
Melo, X; Santa-Clara, H; Santos, D A; Pimenta, N M; Pinto, R; Minderico, C S; Fernhall, B; Sardinha, L B
2016-08-01
Central fatness might be a more sensitive predictor of atherosclerotic changes in children than are total body fat measures. However, it is unclear whether a total body fat measure coupled with an estimate of a more central pattern of fat accumulation predicts increased carotid intima-media-thickness (cIMT) better than either measure alone. The objective of the study is to identify the ability of a combination of simple anthropometric screening tools or a combination of objective measures of body composition to predict cIMT. cIMT was assessed on the common carotid artery in 349 children aged 11-12 years old (183 girls). Body mass index (BMI), waist circumference (WC) and waist-to-height ratio (WHtR) were dichotomized according to established criteria and indices of total body (TBFI) and abdominal (ABFMI) fat were assessed by dual-energy X-ray absorptiometry and categorized (increased risk ≥85%). Single and combined associations among anthropometric and laboratorial measures with the risk of having increased cIMT (≥85%) and discriminatory performance were tested with logistic regression analysis and Receiver Operator Curve analysis. Children with higher total fatness (BMI and TBFI) or higher central pattern of fat accumulation (WC, WHtR and BFMI) were in higher risk for increased cIMT [odds ratio (OR): 2.08-3.24). The risk for increased cIMT was not higher among children who coupled high total and high central fatness (OR: 2.27-3.10). Combination of total and central measures of fat does not improve the prediction of increased cIMT in children. Simple surrogate measures of fatness can be used to predict increased cIMT urging special attention to those children who exhibit increased abdominal fat. © 2015 World Obesity.
Effect of capping layer on spin-orbit torques
NASA Astrophysics Data System (ADS)
Sun, Chi; Siu, Zhuo Bin; Tan, Seng Ghee; Yang, Hyunsoo; Jalil, Mansoor B. A.
2018-04-01
In order to enhance the magnitude of spin-orbit torque (SOT), considerable experimental works have been devoted to studying the thickness dependence of the different layers in multilayers consisting of heavy metal (HM), ferromagnet (FM), and capping layers. Here, we present a theoretical model based on the spin-drift-diffusion formalism to investigate the effect of the capping layer properties such as its thickness on the SOT observed in experiments. It is found that the spin Hall-induced SOT can be significantly enhanced by incorporating a capping layer with an opposite spin Hall angle to that of the HM layer. The spin Hall torque can be maximized by tuning the capping layer thickness. However, in the absence of the spin Hall effect (SHE) in the capping layer, the torque decreases monotonically with the capping layer thickness. Conversely, the spin Hall torque is found to decrease monotonically with the FM layer thickness, irrespective of the presence or absence of the SHE in the capping layer. All these trends are in correspondence with experimental observations. Finally, our model suggests that capping layers with a long spin diffusion length and high resistivity would also enhance the spin Hall torque.
NASA Astrophysics Data System (ADS)
Yu, Hailiang; Lu, Cheng; Tieu, A. Kiet; Li, Huijun; Godbole, Ajit; Kong, Charlie
2018-06-01
The roll bonding technique is one of the most widely used methods to produce metal laminate sheets. Such sheets offer interesting research opportunities for both scientists and engineers. In this paper, we report on an experimental investigation of the 'thickness effect' during laminate rolling for the first time. Using a four-high multifunction rolling mill, Cu/Al/Cu laminate sheets were fabricated with a range of thicknesses (16, 40, 70 and 130 μm) of the Al layer. The thickness of the Cu sheets was a constant 300 μm. After rolling, TEM images show good bonding quality between the Cu and Al layers. However, there are many nanoscale pores in the Al layer. The fraction of nanoscale pores in the Al layer increases with a reduction in the Al layer thickness. The finite element method was used to simulate the Cu/Al/Cu rolling process. The simulation results reveal the effect of the Al layer thickness on the deformation characteristics of the Cu/Al/Cu laminate. Finally, we propose that the size effect of the Al layer thickness during Cu/Al/Cu laminate rolling may offer a method to fabricate 'nanoporous' Al sandwich laminate foils. Such foils can be used in electromagnetic shielding of electrical devices and noisy shielding of building.
NASA Astrophysics Data System (ADS)
Chadel, Meriem; Moustafa Bouzaki, Mohammed; Chadel, Asma; Aillerie, Michel; Benyoucef, Boumediene
2017-07-01
The influence of the thickness of a Zinc Oxide (ZnO) transparent conductive oxide (TCO) layer on the performance of the CZTSSe solar cell is shown in detail. In a photovoltaic cell, the thickness of each layer largely influence the performance of the solar cell and optimization of each layer constitutes a complete work. Here, using the Solar Cell Capacitance Simulation (SCAPS) software, we present simulation results obtained in the analyze of the influence of the TCO layer thickness on the performance of a CZTSSe solar cell, starting from performance of a CZTSSe solar cell commercialized in 2014 with an initial efficiency equal to 12.6%. In simulation, the temperature was considered as a functioning parameter and the evolution of tthe performance of the cell for various thickness of the TCO layer when the external temperature changes is simulated and discussed. The best efficiency of the solar cell based in CZTSSe is obtained with a ZnO thickness equal to 50 nm and low temperature. Based on the considered marketed cell, we show a technological possible increase of the global efficiency achieving 13% by optimization of ZnO based TCO layer.
Recombination zone in white organic light emitting diodes with blue and orange emitting layers
NASA Astrophysics Data System (ADS)
Tsuboi, Taiju; Kishimoto, Tadashi; Wako, Kazuhiro; Matsuda, Kuniharu; Iguchi, Hirofumi
2012-10-01
White fluorescent OLED devices with a 10 nm thick blue-emitting layer and a 31 nm thick orange-emitting layer have been fabricated, where the blue-emitting layer is stacked on a hole transport layer. An interlayer was inserted between the two emitting layers. The thickness of the interlayer was changed among 0.3, 0.4, and 1.0 nm. White emission with CIE coordinates close to (0.33, 0.33) was observed from all the OLEDs. OLED with 0.3 nm thick interlayer gives the highest maximum luminous efficiency (11 cd/A), power efficiency (9 lm/W), and external quantum efficiency (5.02%). The external quantum efficiency becomes low with increasing the interlayer thickness from 0 nm to 1.0 nm. When the location of the blue- and orange-emitting layers is reversed, white emission was not obtained because of too weak blue emission. It is suggested that the electron-hole recombination zone decreases nearly exponentially with a distance from the hole transport layer.
Hashimoto, Yuki; Saito, Wataru; Fujiya, Akio; Yoshizawa, Chikako; Hirooka, Kiriko; Mori, Shohei; Noda, Kousuke; Ishida, Susumu
2015-01-01
Purpose To investigate sequential post-operative thickness changes in inner and outer retinal layers in eyes with an idiopathic macular hole (MH). Methods Retrospective case series. Twenty-four eyes of 23 patients who had received pars plana vitrectomy (PPV) for the closure of MH were included in the study. Spectral domain optical coherence tomography C-scan was used to automatically measure the mean thickness of the inner and outer retinal layers pre-operatively and up to 6 months following surgery. The photoreceptor outer segment (PROS) length was measured manually and was used to assess its relationship with best-corrected visual acuity (BCVA). Results Compared with the pre-operative thickness, the inner layers significantly thinned during follow-up (P = 0.02), particularly in the parafoveal (P = 0.01), but not perifoveal, area. The post-operative inner layer thinning ranged from the ganglion cell layer to the inner plexiform layer (P = 0.002), whereas the nerve fiber layer was unaltered. Outer layer thickness was significantly greater post-operatively (P = 0.002), and especially the PROS lengthened not only in the fovea but also in the parafovea (P < 0.001). Six months after surgery, BCVA was significantly correlated exclusively with the elongated foveal PROS (R = 0.42, P = 0.03), but not with any of the other thickness parameters examined. Conclusions Following PPV for MH, retinal inner layers other than the nerve fiber layer thinned, suggestive of subclinical thickening in the inner layers where no cyst was evident pre-operatively. In contrast, retinal outer layer thickness significantly increased, potentially as a result of PROS elongation linking tightly with favorable visual prognosis in MH eyes. PMID:26291526
Turan, Kadriye Erkan; Sekeroglu, Hande Taylan; Baytaroglu, Ata; Bezci, Figen; Karahan, Sevilay
2018-01-01
To (a) determine the normative values for optical coherence tomography (OCT) parameters such as central macular thickness, retinal nerve fiber layer thickness, and choroidal thickness in healthy children; (b) investigate the relationships of these parameters with axial length, central corneal thickness, refractive errors, and intraocular pressure; and (c) determine interexaminer agreement for choroidal thickness measurements. In this cross-sectional study, 120 healthy children aged 8-15 years underwent detailed ophthalmological examination and OCT measurements. Choroidal thickness was measured at three separate locations by two independent examiners. The mean global retinal nerve fiber layer thickness was 98.75 ± 9.45 μm (79.0-121.0). The mean central macular thickness was 232.29 ± 29.37 μm (190.0-376.0). The mean subfoveal choroidal thickness obtained by examiner 1 was 344.38 ± 68.83 μm and that obtained by examiner 2 was 344.04 ± 68.92 μm. Interexaminer agreement was between 99.6%-99.8% for choroidal thickness at three separate locations. Central macular thickness increased with axial length (r=0.245, p=0.007). Choroidal thickness increased with age (r=0.291, p=0.001) and decreased with axial length (r=-0.191, p=0.037). Global retinal nerve fiber layer thickness decreased with axial length (r=-0.247, p=0.007) and increased with central corneal thickness (r=0.208, p=0.022). Global retinal nerve fiber layer thickness positively correlated with choroidal thickness (r=0.354, p<0.001). Global retinal nerve fiber layer thickness (r=0.223, p=0.014) and choroidal thickness (r=0.272, p=0.003) increased with the spherical equivalent (D). Optical coherence tomography parameters showed a wide range of variability in children. Retinal nerve fiber layer thickness, central macular thickness, and choroidal thickness were found to be either inter-related or correlated with age, central corneal thickness, axial length, and refractive errors. Furthermore, manual measurements of choroidal thickness showed high interexaminer agreement. Because normative values for optical coherence tomography parameters differed in children, the measurements should be interpreted according to an age-appropriate database.
Choroidal Haller's and Sattler's Layers Thickness in Normal Indian Eyes.
Roy, Rupak; Saurabh, Kumar; Vyas, Chinmayi; Deshmukh, Kaustubh; Sharma, Preeti; Chandrasekharan, Dhileesh P; Bansal, Aditya
2018-01-01
This study aims to study normative choroidal thickness (CT) and Haller's and Sattler's layers thickness in normal Indian eyes. The choroidal imaging of 73 eyes of 43 healthy Indian individuals was done using enhanced depth imaging feature of spectralis optical coherence tomography. Rraster scan protocol centered at fovea was used for imaging separately by two observers. CT was defined as the length of the perpendicular line drown from the outer border of hypereflective RPE-Bruch's complex to inner margin of choroidoscleral junction. Choroidal vessel layer thickness was measured after defining a largest choroidal vessel lumen within 750 μ on either side of the subfoveal CT vector. A perpendicular line was drawn to the innermost border of this lumen, and the distance between the perpendicular line and innermost border of choroidoscleral junction gave large choroidal vessel layer thickness (LCVLT, Haller's layer). Medium choroidal vessel layer thickness (MCVLT, Sattler's layer) was measured as the distance between same perpendicular line and outer border of hypereflective RPE-Bruch's complex. The mean age of individuals was 28.23 ± 15.29 years (range 14-59 years). Overall, the mean subfoveal CT was 331.6 ± 63.9 μ. Mean LCVLT was 227.08 ± 51.24 μ and the mean MCVLT was 95.65 ± 23.62 μ. CT was maximum subfoveally with gradual reduction in the thickness as the distance from the fovea increased. This is the first study describing the choroidal sublayer thickness, i.e., Haller's and Sattler's layer thickness along with CT in healthy Indian population.
Choroidal Haller's and Sattler's Layers Thickness in Normal Indian Eyes
Roy, Rupak; Saurabh, Kumar; Vyas, Chinmayi; Deshmukh, Kaustubh; Sharma, Preeti; Chandrasekharan, Dhileesh P.; Bansal, Aditya
2018-01-01
AIM: This study aims to study normative choroidal thickness (CT) and Haller's and Sattler's layers thickness in normal Indian eyes. MATERIALS AND METHODS: The choroidal imaging of 73 eyes of 43 healthy Indian individuals was done using enhanced depth imaging feature of spectralis optical coherence tomography. Rraster scan protocol centered at fovea was used for imaging separately by two observers. CT was defined as the length of the perpendicular line drown from the outer border of hypereflective RPE-Bruch's complex to inner margin of choroidoscleral junction. Choroidal vessel layer thickness was measured after defining a largest choroidal vessel lumen within 750 μ on either side of the subfoveal CT vector. A perpendicular line was drawn to the innermost border of this lumen, and the distance between the perpendicular line and innermost border of choroidoscleral junction gave large choroidal vessel layer thickness (LCVLT, Haller's layer). Medium choroidal vessel layer thickness (MCVLT, Sattler's layer) was measured as the distance between same perpendicular line and outer border of hypereflective RPE-Bruch's complex. RESULTS: The mean age of individuals was 28.23 ± 15.29 years (range 14–59 years). Overall, the mean subfoveal CT was 331.6 ± 63.9 μ. Mean LCVLT was 227.08 ± 51.24 μ and the mean MCVLT was 95.65 ± 23.62 μ. CT was maximum subfoveally with gradual reduction in the thickness as the distance from the fovea increased. CONCLUSION: This is the first study describing the choroidal sublayer thickness, i.e., Haller's and Sattler's layer thickness along with CT in healthy Indian population. PMID:29899646
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutter, P., E-mail: psutter@bnl.gov; Sutter, E.
2014-09-01
We assess scanning electron microscopy (SEM) and Auger electron spectroscopy (AES) for thickness measurements on few-layer hexagonal boron nitride (h-BN), the layered dielectric of choice for integration with graphene and other two-dimensional materials. Observations on h-BN islands with large, atomically flat terraces show that the secondary electron intensity in SEM reflects monolayer height changes in films up to least 10 atomic layers thickness. From a quantitative analysis of AES data, the energy-dependent electron escape depth in h-BN films is deduced. The results show that AES is suitable for absolute thickness measurements of few-layer h-BN of 1 to 6 layers.
Dencker, Magnus; Arvidsson, Daniel; Karlsson, Magnus K; Wollmer, Per; Andersen, Lars B; Thorsson, Ola
2018-03-01
Galectin-3 has recently been proposed as a novel biomarker for cardiovascular disease in adults. The purpose of this investigation was to assess relationships between galectin-3 levels and total body fat, abdominal fat, body fat distribution, aerobic fitness, blood pressure, left ventricular mass, left atrial size, and increase in body fat over a 2-year period in a population-based sample of children. Our study included 170 children aged 8-11 years. Total fat mass and abdominal fat were measured by dual-energy x-ray absorptiometry (DXA). Body fat distribution was expressed as abdominal fat/total fat mass. Maximal oxygen uptake was assessed by indirect calorimetry during a maximal exercise test and scaled to body mass. Systolic and diastolic blood pressure and pulse pressure were measured. Left atrial size, left ventricular mass, and relative wall thickness were measured by echocardiography. Frozen serum samples were analyzed for galectin-3 by the Proximity Extension Assay technique. A follow-up DXA scan was performed in 152 children 2 years after the baseline exam. Partial correlations, with adjustment for sex and age, between galectin-3 versus body fat measurements indicated weak to moderate relationships. Moreover, left atrial size, left ventricular mass, and relative wall thickness and pulse pressure were also correlated with galectin-3. Neither systolic blood pressure nor maximal oxygen uptake was correlated with galectin-3. There was also a correlation between galectin-3 and increase in total body fat over 2 years, while no such correlations were found for the other fat measurements. More body fat and abdominal fat, more abdominal body fat distribution, more left ventricular mass, and increased left atrial size were all associated with higher levels of galectin-3. Increase in total body fat over 2 years was also associated with higher levels of galectin-3. What is Known: • Galectin-3 has been linked to obesity and been proposed to be a novel biomarker for cardiovascular disease in adults. • Information on this subject in children is very scarce. What is New: • The present study demonstrates a relationship between galectin-3 levels and total body fat, abdominal fat, body fat distribution, cardiac size and geometry, and increase in total body fat over 2 years in young children.
Impact of the cardiovascular system-associated adipose tissue on atherosclerotic pathology.
Chistiakov, Dimitry A; Grechko, Andrey V; Myasoedova, Veronika A; Melnichenko, Alexandra A; Orekhov, Alexander N
2017-08-01
Cardiac obesity makes an important contribution to the pathogenesis of cardiovascular disease. One of the important pathways of this contribution is the inflammatory process that takes place in the adipose tissue. In this review, we consider the role of the cardiovascular system-associated fat in atherosclerotic cardiovascular pathology and a non-atherosclerotic cause of coronary artery disease, such as atrial fibrillation. Cardiovascular system-associated fat not only serves as the energy store, but also releases adipokines that control local and systemic metabolism, heart/vascular function and vessel tone, and a number of vasodilating and anti-inflammatory substances. Adipokine appears to play an important protective role in cardiovascular system. Under chronic inflammation conditions, the repertoire of signaling molecules secreted by cardiac fat can be altered, leading to a higher amount of pro-inflammatory messengers, vasoconstrictors, profibrotic modulators. This further aggravates cardiovascular inflammation and leads to hypertension, induction of the pathological tissue remodeling and cardiac fibrosis. Contemporary imaging techniques showed that epicardial fat thickness correlates with the visceral fat mass, which is an established risk factor and predictor of cardiovascular disease in obese subjects. However, this correlation is no longer present after adjustment for other covariates. Nevertheless, recent studies showed that pericardial fat volume and epicardial fat thickness can probably serve as a better indicator for atrial fibrillation. Copyright © 2017 Elsevier B.V. All rights reserved.
Survey of Mexican retail stores for US beef product.
Huerta-Leidenz, Nelson; Ruíz-Flores, Agustín; Maldonado-Siman, Ema; Valdéz, Alejandra; Belk, Keith E
2014-02-01
Retail packages (N=1004) containing fresh US beef in display cases in five cities across three regions of Mexico were surveyed for cut types, cutting styles, fat thickness measurements, marbling scores, and USDA Quality Grades to gain an overview of fresh US beef in Mexican retail markets. Data were analyzed to generate frequency distributions and examine the effect of city, geographical region, store chain, and socio-economic status of the targeted clientele on type, cutting style, fat measures and quality of beef cuts of US origin. Top round, bottom round and knuckle were the most common cut types. Milanesa-type slice and "bistec" (steak for grilling) were the predominant cutting styles. Over 95% of the retail cuts were trimmed to 3.2mm or less of external fat. Most cuts were USDA Select (74.5%) and USDA Choice (24.5%). External fat thickness and marbling score differed among cities and store chains (P<0.01). © 2013. Published by Elsevier Ltd. All rights reserved.
The Effects of Dietary Macronutrient Balance on Skin Structure in Aging Male and Female Mice
McMahon, Aisling C.; Ruohonen, Kari; Raubenheimer, David; Ballard, J. William O.; Le Couteur, David G.; Nicholls, Caroline; Li, Zhe; Maitz, Peter K. M.; Wang, Yiwei; Simpson, Stephen J.
2016-01-01
Nutrition influences skin structure; however, a systematic investigation into how energy and macronutrients (protein, carbohydrate and fat) affects the skin has yet to be conducted. We evaluated the associations between macronutrients, energy intake and skin structure in mice fed 25 experimental diets and a control diet for 15 months using the Geometric Framework, a novel method of nutritional analysis. Skin structure was associated with the ratio of dietary macronutrients eaten, not energy intake, and the nature of the effect differed between the sexes. In males, skin structure was primarily associated with protein intake, whereas in females carbohydrate intake was the primary correlate. In both sexes, the dermis and subcutaneous fat thicknesses were inversely proportional. Subcutaneous fat thickness varied positively with fat intake, due to enlarged adipocytes rather than increased adipocyte number. We therefore demonstrated clear interactions between skin structure and macronutrient intakes, with the associations being sex-specific and dependent on dietary macronutrient balance. PMID:27832138
Jankowski, Marek; Gawrych, Mariusz; Adamska, Urszula; Ciescinski, Jakub; Serafin, Zbigniew; Czajkowski, Rafal
2017-02-01
Low-level laser (light) therapy (LLLT) has been applied recently to body contouring. However the mechanism of LLLT-induced reduction of subcutaneous adipose tissue thickness has not been elucidated and proposed hypotheses are highly controversial. Non-obese volunteers were subject to 650nm LLLT therapy. Each patient received 6 treatments 2-3 days apart to one side of the abdomen. The contralateral side was left untreated and served as control. Subjects' abdominal adipose tissue thickness was measured by ultrasound imaging at baseline and 2 weeks post-treatment. Our study is to the best of our knowledge, the largest split-abdomen study employing subcutaneous abdominal fat imaging. We could not show a statistically significant reduction of abdominal subcutaneous adipose tissue by LLLT therapy. Paradoxically when the measurements of the loss of fat thickness on treated side was corrected for change in thickness on non treated side, we have observed that in 8 out of 17 patients LLLT increased adipose tissue thickness. In two patients severe side effect occurred as a result of treatment: one patient developed ulceration within appendectomy scar, the other over the posterior superior iliac spine. The paradoxical net increase in subcutaneous fat thickness observed in some of our patients is a rationale against liquefactive and transitory pore models of LLLT-induced adipose tissue reduction. LLLT devices with laser diode panels applied directly on the skin are not as safe as devices with treatment panels separated from the patient's skin.
Flow characteristics and scaling past highly porous wall-mounted fences
NASA Astrophysics Data System (ADS)
Rodríguez-López, Eduardo; Bruce, Paul J. K.; Buxton, Oliver R. H.
2017-07-01
An extensive characterization of the flow past wall-mounted highly porous fences based on single- and multi-scale geometries has been performed using hot-wire anemometry in a low-speed wind tunnel. Whilst drag properties (estimated from the time-averaged momentum equation) seem to be mostly dependent on the grids' blockage ratio; wakes of different size and orientation bars seem to generate distinct behaviours regarding turbulence properties. Far from the near-grid region, the flow is dominated by the presence of two well-differentiated layers: one close to the wall dominated by the near-wall behaviour and another one corresponding to the grid's wake and shear layer, originating from between this and the freestream. It is proposed that the effective thickness of the wall layer can be inferred from the wall-normal profile of root-mean-square streamwise velocity or, alternatively, from the wall-normal profile of streamwise velocity correlation. Using these definitions of wall-layer thickness enables us to collapse different trends of the turbulence behaviour inside this layer. In particular, the root-mean-square level of the wall shear stress fluctuations, longitudinal integral length scale, and spanwise turbulent structure is shown to display a satisfactory scaling with this thickness rather than with the whole thickness of the grid's wake. Moreover, it is shown that certain grids destroy the spanwise arrangement of large turbulence structures in the logarithmic region, which are then re-formed after a particular streamwise extent. It is finally shown that for fences subject to a boundary layer of thickness comparable to their height, the effective thickness of the wall layer scales with the incoming boundary layer thickness. Analogously, it is hypothesized that the growth rate of the internal layer is also partly dependent on the incoming boundary layer thickness.
Henneberg, Maciej; Ulijaszek, Stanley J
2010-01-01
We explore relationships between BMI and skinfolds and anthropometric variables reflecting variation in lean body frame. Data on the middle class adult Australian women (n = 1260) collected in 2002 during a National Body Size and Shape Survey were used. Standard measurements of stature, weight, skeletal dimensions (shoulder width, hip width, chest width, and depth, limb lengths), circumferences of head, trunk, limbs and triceps, subscapular and abdominal skinfolds were taken. Techniques for measurements of skeletal frame minimized the inclusion of adipose tissue thickness. Analysis of variance and parametric and nonparametric correlations were used. Vertical dimensions show weak correlations with fatness, while body frame circumferences and transverse dimensions are consistently, significantly, and substantially correlated with fatness, each explaining from 3 to 44% of variation in skinfold thickness. Skeletal dimensions explain up to 50% of variation in skinfold thickness (multiple regression). Especially high correlations with skinfold thickness occur for chest width, depth, and hip width (r range from 0.42 to 0.66). Body frame dimensions reflect largely trunk volume and the trunk/limb proportions. Larger lean trunk size is associated with greater fatness. Since the size of the abdominal cavity, and thus the gastrointestinal system (GI), is reflected in the trunk size, we speculate that larger frame may predispose to obesity in two ways: (1) larger stomachs require greater bulk of food to produce feeling of satiety as mediated through antral distension, (2) larger GIs may absorb more nutrients. Frame size may help to detect the risk of obesity among young adults. 2009 Wiley-Liss, Inc.
Shulman, S; Shorer, R; Wollman, J; Dotan, G; Paran, D
2017-11-01
Background Cognitive impairment is frequent in systemic lupus erythematosus. Atrophy of the corpus callosum and hippocampus have been reported in patients with systemic lupus erythematosus, and diffusion tensor imaging studies have shown impaired white matter integrity, suggesting that white matter damage in systemic lupus erythematosus may underlie the cognitive impairment as well as other neuropsychiatric systemic lupus erythematosus manifestations. Retinal nerve fiber layer thickness, as assessed by optical coherence tomography, has been suggested as a biomarker for white matter damage in neurologic disorders such as multiple sclerosis, Alzheimer's disease and Parkinson's disease. Retinal nerve fiber layer thinning may occur early, even in patients with mild clinical symptoms. Aim The objective of this study was to assess the association of retinal nerve fiber layer thickness, as a biomarker of white matter damage in systemic lupus erythematosus patients, with neuropsychiatric systemic lupus erythematosus manifestations, including cognitive impairment. Methods Twenty-one consecutive patients with systemic lupus erythematosus underwent neuropsychological testing using a validated computerized battery of tests as well as the Rey-Auditory verbal learning test. All 21 patients, as well as 11 healthy, age matched controls, underwent optical coherence tomography testing to assess retinal nerve fiber layer thickness. Correlations between retinal nerve fiber layer thickness and results in eight cognitive domains assessed by the computerized battery of tests as well as the Rey-Auditory verbal learning test were assessed in patients with systemic lupus erythematosus, with and without neuropsychiatric systemic lupus erythematosus, and compared to retinal nerve fiber layer thickness in healthy controls. Results No statistically significant correlation was found between retinal nerve fiber layer thickness in patients with systemic lupus erythematosus as compared to healthy controls. When evaluating by subgroups, no correlation was found between patients with or without neuropsychiatric systemic lupus erythematosus or cognitive impairment and retinal nerve fiber layer thickness. Conclusion Retinal nerve fiber layer thickness of systemic lupus erythematosus patients was not found to be statistically different compared to controls. Within systemic lupus erythematosus patients there was no correlation between retinal nerve fiber layer thickness and cognitive impairment or other neuropsychiatric systemic lupus erythematosus manifestations.
del Busto-Mesa, Abdel; Cabrera-Rego, Julio Oscar; Carrero-Fernández, Lisván; Hernández-Roca, Cristina Victoria; González-Valdés, Jorge Luis; de la Rosa-Pazos, José Eduardo
2015-01-01
To assess the relationship between primary hypothyroidism and subclinical atherosclerosis and its potential changes with L-thyroxine replacement therapy. A prospective cohort study including 101 patients with primary hypothyroidism and 101 euthyroid patients as controls was conducted from July 2011 to December 2013. Clinical, anthropometrical, biochemical, and ultrasonographic parameters were assessed at baseline and after one year of L-thyroxine replacement therapy. At baseline, hypothyroid patients had significantly greater values of blood pressure, total cholesterol, VLDL cholesterol, left ventricular mass, epicardial fat, and carotid intima-media thickness as compared to controls. Total cholesterol, VLDL cholesterol, ventricular diastolic function, epicardial fat, carotid intima-media thickness, carotid local pulse wave velocity, pressure strain elastic modulus, and β arterial stiffness index showed a significant and positive correlation with TSH levels. After one year of replacement therapy, patients with hypothyroidism showed changes in total cholesterol, VLDL cholesterol, TSH, carotid intima-media thickness, and arterial stiffness parameters. Primary hypothyroidism is characterized by an increased cardiovascular risk. In these patients, L-thyroxine replacement therapy for one year is related to decreased dyslipidemia and improvement in markers of subclinical carotid atherosclerosis. Copyright © 2014 SEEN. Published by Elsevier España, S.L.U. All rights reserved.
Lopes, P A; Martins, A P; Martins, S V; Madeira, M S; Santos, N C; Moura, T F; Prates, J A M; Soveral, G
2017-04-01
The production of pork with moderate amounts of intramuscular fat (IMF) without an increase in subcutaneous fat is highly desirable for the meat industry. Several studies indicate that dietary protein reduction during the growing-finishing period of pigs enhances IMF content, but its consequence on carcass fat deposition is still contradictory. In this study, we hypothesized that the effects of reduced protein diets (RPD), corrected or not with the limiting amino acid lysine, on subcutaneous fat deposition from pigs with distinct genotypes are mediated by adipose membranes biophysical properties. In total, 36 crossbred (Large White×Landrace×Pietrain - a lean genotype) and purebred (Alentejana breed - a fatty genotype) male pigs were randomly assigned to the control group, the RPD group or the reduced protein diet equilibrated for lysine (RPDL) group, allowing a 2×3 factorial arrangement (n=6). Backfat thickness and total fatty acid content were higher in Alentejana relative to crossbred pigs. Although dietary treatments did not change backfat thickness, RPD and RPDL increased total fatty acids content of subcutaneous fat. In order to understand this effect, adipose tissue membranes isolated from pig's subcutaneous fat were assayed for glycerol permeability and fluidity, using 1,6-diphenyl-1,3,5-hexatriene (DPH) and 1-(4-(trimethylamino)-phenyl)-6-phenyl-1,3,5-hexatriene (TMA-DPH) probes. The glycerol transport across adipose membranes was not mediated by aquaglyceroporins and remained unchanged across dietary groups. Regardless of lysine correction, RPD increased membrane fluidity at the hydrocarbon region (lower DPH fluorescence anisotropy) in both genotypes of pigs. This result was associated with a lower ratio between oleic acid and linoleic acid on membrane's fatty acid composition. Adipose membrane's cholesterol content was independent from genotype and diet. Taken together, the present study shows that dietary protein reduction is successful in maintaining backfat thickness, although a negative side effect was observed on total fatty acids in subcutaneous fat, which may be due to changes in the fluidity of adipose membranes.
Demel, Anja; Feilke, Katharina; Wolf, Martin; Poets, Christian F; Franz, Axel R
2014-01-01
Near-infrared spectroscopy (NIRS) is increasingly used in neonatal intensive care. We investigated the impact of skin, bone, and cerebrospinal fluid (CSF) layer thickness in term and preterm infants on absorption-(μa) and/or reduced scattering coefficients (μs') measured by multidistance frequency-domain (FD)-NIRS. Transcranial ultrasound was performed to measure the layer thicknesses. Correlations were only statistically significant for μa at 692 nm with bone thickness and μs' at 834 nm with skin thickness. There is no evidence that skin, bone, or CSF thickness have an important effect on μa and μs'. Layer thicknesses of skin, bone, and CSF in the range studied do not seem to affect cerebral oxygenation measurements by multidistance FD-NIRS significantly.
What is the copper thin film thickness effect on thermal properties of NiTi/Cu bi-layer?
NASA Astrophysics Data System (ADS)
Fazeli, Sara; Vahedpour, Morteza; Khatiboleslam Sadrnezhaad, Sayed
2017-02-01
Molecular dynamics (MD) simulation was used to study of thermal properties of NiTi/Cu. Embedded atom method (EAM) potentials for describing of inter-atomic interaction and Nose-Hoover thermostat and barostat are employed. The melting of the bi-layers was considered by studying the temperature dependence of the cohesive energy and mean square displacement. To highlight the differences between bi-layers with various copper layer thickness, the effect of copper film thickness on thermal properties containing the cohesive energy, melting point, isobaric heat capacity and latent heat of fusion was estimated. The results show that thermal properties of bi-layer systems are higher than that of their corresponding of pure NiTi. But, these properties of bi-layer systems approximately are independent of copper film thicknesses. The mean square displacement (MSD) results show that, the diffusion coefficients enhance upon increasing of copper film thickness in a linear performance.
NASA Astrophysics Data System (ADS)
Srinivasan, M. A.; Rao, C. Dhananjaya; Krishnaiah, M.
2016-05-01
The present study describes Mie lidar observations of the cirrus cloud passage showing transition between double thin layers into single thick and single thick layer into double thin layers of cirrus over Gadanki region. During Case1: 17 January 2007, Case4: 12 June 2007, Case5: 14 July 2007 and Case6: 24 July 2007 the transition is found to from two thin cirrus layers into single geometrically thick layer. Case2: 14 May 2007 and Case3: 15 May 2007, the transition is found to from single geometrically thick layer into two thin cirrus layers. Linear Depolarization Ratio (LDR) and Back Scatter Ration (BSR) are found to show similar variation with strong peaks during transition; both LDR and Cloud Optical Depth (COD) is found to show similar variation except during transition with strong peaks in COD which is not clearly found from LDR for the all cases. There is a significant weakening of zonal and meridional winds during Case1 which might be due to the transition from multiple to single thick cirrus indicating potential capability of thick cirrus in modulating the wind fields. There exists strong upward wind dominance contributed to significant ascent in cloud-base altitude thereby causing transition of multiple thin layers into single thick cirrus.
Control of Alq3 wetting layer thickness via substrate surface functionalization.
Tsoi, Shufen; Szeto, Bryan; Fleischauer, Michael D; Veinot, Jonathan G C; Brett, Michael J
2007-06-05
The effects of substrate surface energy and vapor deposition rate on the initial growth of porous columnar tris(8-hydroxyquinoline)aluminum (Alq3) nanostructures were investigated. Alq3 nanostructures thermally evaporated onto as-supplied Si substrates bearing an oxide were observed to form a solid wetting layer, likely caused by an interfacial energy mismatch between the substrate and Alq3. Wetting layer thickness control is important for potential optoelectronic applications. A dramatic decrease in wetting layer thickness was achieved by depositing Alq3 onto alkyltrichlorosilane-derivatized Si/oxide substrates. Similar effects were noted with increasing deposition rates. These two effects enable tailoring of the wetting layer thickness.
Molecular beam epitaxy of large-area SnSe2 with monolayer thickness fluctuation
NASA Astrophysics Data System (ADS)
Park, Young Woon; Jerng, Sahng-Kyoon; Jeon, Jae Ho; Roy, Sanjib Baran; Akbar, Kamran; Kim, Jeong; Sim, Yumin; Seong, Maeng-Je; Kim, Jung Hwa; Lee, Zonghoon; Kim, Minju; Yi, Yeonjin; Kim, Jinwoo; Noh, Do Young; Chun, Seung-Hyun
2017-03-01
The interest in layered materials is largely based on the expectation that they will be beneficial for a variety of applications, from low-power-consuming, wearable electronics to energy harvesting. However, the properties of layered materials are highly dependent on thickness, and the difficulty of controlling thickness over a large area has been a bottleneck for commercial applications. Here, we report layer-by-layer growth of SnSe2, a layered semiconducting material, via van der Waals epitaxy. The films were fabricated on insulating mica substrates with substrate temperatures in the range of 210 °C-370 °C. The surface consists of a mixture of N and (N ± 1) layers, showing that the thickness of the film can be defined with monolayer accuracy (±0.6 nm). High-resolution transmission electron microscopy reveals a polycrystalline film with a grain size of ˜100 nm and clear Moiré patterns from overlapped grains with similar thickness. We also report field effect mobility values of 3.7 cm2 V-1 s-1 and 6.7 cm2 V-1 s-1 for 11 and 22 nm thick SnSe2, respectively. SnSe2 films with customizable thickness can provide valuable platforms for industry and academic researchers to fully exploit the potential of layered materials.
NASA Astrophysics Data System (ADS)
Cheng, Shiwang; Carrillo, Jan-Michael Y.; Carroll, Bobby; Sumpter, Bobby G.; Sokolov, Alexei P.
There are growing experimental evidences showing the existence of an interfacial layer that has a finite thickness with slowing down dynamics in polymer nanocomposites (PNCs). Moreover, it is believed that the interfacial layer plays a significant role on various macroscopic properties of PNCs. A thicker interfacial layer is found to have more pronounced effect on the macroscopic properties such as the mechanical enhancement. However, it is not clear what molecular parameter controls the interfacial layer thickness. Inspired by our recent computer simulations that showed the chain rigidity correlated well with the interfacial layer thickness, we performed systematic experimental studies on different polymer nanocomposites by varying the chain stiffness. Combining small-angle X-ray scattering, broadband dielectric spectroscopy and temperature modulated differential scanning calorimetry, we find a good correlation between the polymer Kuhn length and the thickness of the interfacial layer, confirming the earlier computer simulations results. Our findings provide a direct guidance for the design of new PNCs with desired properties.
NASA Astrophysics Data System (ADS)
Nakami, S.; Narioka, T.; Kobayashi, T.; Nagase, T.; Naito, H.
2017-11-01
The dependence of active-layer thickness on the power conversion efficiency (PCE) of inverted organic photovoltaics (OPVs) based on poly(3-hexylthiphene) and [6,6]-phenyl-C61-butyric acid methyl ester was investigated. When PCEs were measured immediately after device fabrication, the optimum thickness was ~100 nm. It was, however, found that thick OPVs exhibit higher PCEs a few months later, whereas thin OPVs simply degraded with time. Consequently, the optimum thickness changed with time. Considering this fact, we discuss the relationship between the active-layer thickness and PCE.
Domain epitaxy for thin film growth
Narayan, Jagdish
2005-10-18
A method of forming an epitaxial film on a substrate includes growing an initial layer of a film on a substrate at a temperature T.sub.growth, said initial layer having a thickness h and annealing the initial layer of the film at a temperature T.sub.anneal, thereby relaxing the initial layer, wherein said thickness h of the initial layer of the film is greater than a critical thickness h.sub.c. The method further includes growing additional layers of the epitaxial film on the initial layer subsequent to annealing. In some embodiments, the method further includes growing a layer of the film that includes at least one amorphous island.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Wug-Dong; Tanioka, Kenkichi
Amorphous selenium (a-Se) high-gain avalanche rushing amorphous photoconductor (HARP) film has been used for highly sensitive imaging devices. To improve the spectral response of a-Se HARP photoconductive film at a long wavelength, the tellurium (Te) doping effect in an 8-μm-thick a-Se HARP film was investigated. The thickness of the Te-doped a-Se layer in the 8-μm-thick a-Se HARP films was varied from 60 to 120 nm. The signal current increases significantly due to the avalanche multiplication when the target voltage is increased over the threshold voltage. In the 8-μm-thick a-Se HARP film with a Te-doped layer, the spectral response at a longmore » wavelength was improved in comparison with the a-Se HARP film without a Te-doped layer. In addition, the increase of the lag in the 8-μm-thick a-Se HARP target with a Te-doped layer of 120 nm is caused by the photoconductive lag due to the electrons trapped in the Te-doped layer. Based on the current-voltage characteristics, spectral response, and lag characteristics of the 8-μm-thick a-Se HARP targets, the Te-doped layer thickness of 90 nm is suitable for the 8-μm-thick a-Se HARP film.« less
Tellurium doping effect in avalanche-mode amorphous selenium photoconductive film
NASA Astrophysics Data System (ADS)
Park, Wug-Dong; Tanioka, Kenkichi
2014-11-01
Amorphous selenium (a-Se) high-gain avalanche rushing amorphous photoconductor (HARP) film has been used for highly sensitive imaging devices. To improve the spectral response of a-Se HARP photoconductive film at a long wavelength, the tellurium (Te) doping effect in an 8-μm-thick a-Se HARP film was investigated. The thickness of the Te-doped a-Se layer in the 8-μm-thick a-Se HARP films was varied from 60 to 120 nm. The signal current increases significantly due to the avalanche multiplication when the target voltage is increased over the threshold voltage. In the 8-μm-thick a-Se HARP film with a Te-doped layer, the spectral response at a long wavelength was improved in comparison with the a-Se HARP film without a Te-doped layer. In addition, the increase of the lag in the 8-μm-thick a-Se HARP target with a Te-doped layer of 120 nm is caused by the photoconductive lag due to the electrons trapped in the Te-doped layer. Based on the current-voltage characteristics, spectral response, and lag characteristics of the 8-μm-thick a-Se HARP targets, the Te-doped layer thickness of 90 nm is suitable for the 8-μm-thick a-Se HARP film.
Hauffa, B P; Schlippe, G; Gillessen-Kaesbach, G
2001-05-01
Morbid obesity develops as a result of hyperphagia and compulsive eating behavior in patients with Prader-Willi syndrome (PWS), if caloric intake is not rigorously controlled. PWS-specific centile curves for adiposity indices constructed in the past were based on clinically diagnosed patients. With the advent of molecular genetic methods, allowing for an unequivocal diagnosis, new PWS curves based exclusively on molecularly diagnosed patients are becoming available, eliminating a potential diagnostic bias. To compare fat distribution in molecularly confirmed German PWS patients to that of clinically diagnosed American PWS patients and a healthy reference population. Cross-sectional anthropometric study. One hundred German patients (49 F) with molecularly confirmed PWS (age: <30 y). Triceps (subscapular) skinfold thickness, waist and hip circumference. Skinfold thickness was massively elevated in the majority of the molecularly confirmed German PWS patients compared to a healthy reference population. Whereas triceps skinfold thickness was in good agreement with American PWS patients, subscapular skinfold thickness in German girls rose earlier than in American PWS girls, indicating possible differences between caloric intake or the proportion of patients entering puberty spontaneously. Waist circumference and waist-hip ratio (n=89) were elevated in a relative small proportion of patients only and did not reflect lower abdominal fat. This may be due to the peculiar shape of many patients with a typical fat accumulation around the buttocks. In addition to body mass index, use of skinfold thickness is recommended for follow-up of dietary interventions in PWS.
Boey, Gerald E; Wasilenchuk, Jennifer L
2014-01-01
Cryolipolysis procedures have been shown to safely and effectively reduce the thickness of fat in a treated region. This study was conducted to determine whether the addition of post-treatment manual massage would improve efficacy while maintaining the safety profile of the original cryolipolysis treatment protocol. The study population consisted of an efficacy group (n = 10) and a safety group (n = 7). Study subjects were treated on each side of the lower abdomen with a Cooling Intensity Factor of 42 (-72.9 mW/cm(2) ) for 60 minutes. One side of the abdomen was massaged post-treatment and the other side served as the control. Immediately post-treatment, the massage side was treated for 1 minute using a vigorous kneading motion followed by 1 minute of circular massage using the pads of the fingers. For the efficacy group, photos and ultrasound measurements were taken at baseline, 2 months, and 4 months post-treatment. For the safety group, histological analysis was completed at 0, 3, 8, 14, 30, 60, and 120 days post-treatment to examine the effects of massage on subcutaneous tissue over time. Post-treatment manual massage resulted in a consistent and discernible increase in efficacy over the non-massaged side. At 2 months post-treatment, mean fat layer reduction was 68% greater in the massage side than in the non-massage side as measured by ultrasound. By 4 months, mean fat layer reduction was 44% greater in the massage side. Histological results showed no evidence of necrosis or fibrosis resulting from the massage. Post-treatment manual massage is a safe and effective technique to enhance the clinical outcome from a cryolipolysis procedure. © 2013 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.
Simulation of cryolipolysis as a novel method for noninvasive fat layer reduction.
Majdabadi, Abbas; Abazari, Mohammad
2016-12-20
Regarding previous problems in conventional liposuction methods, the need for development of new fat removal operations was appreciated. In this study we are going to simulate one of the novel methods, cryolipolysis, aimed to tackle those drawbacks. We think that simulation of clinical procedures contributes considerably in efficacious performance of the operations. To do this we have attempted to simulate temperature distribution in a sample fat of the human body. Using Abaqus software we have presented the graphical display of temperature-time variations within the medium. Findings of our simulation indicate that tissue temperature decreases after cold exposure of about 30 min. It can be seen that the minimum temperature of tissue occurs in shallow layers of the sample and the temperature in deeper layers of the sample remains nearly unchanged. It is clear that cold exposure time of more than the specific time (t > 30 min) does not result in considerable changes. Numerous clinical studies have proved the efficacy of cryolipolysis. This noninvasive technique has eliminated some of drawbacks of conventional methods. Findings of our simulation clearly prove the efficiency of this method, especially for superficial fat layers.
Soyama, Akiko; Nishikawa, Tetsuo; Ishizuka, Toshiharu; Ito, Hiroko; Saito, Jun; Yagi, Kazuo; Saito, Yasushi
2005-04-01
For this study we enrolled 1,615 males who were admitted to our hospital for a general health check-up. Plasma glucose (PG) and insulin were measured during 75 g OGTT, and abdominal obesity was assessed by ultrasonography in all subjects. We divided them into several groups: normal glucose tolerance (NGT), high-normal glucose tolerance (h-NGT) who showed >10.0 nmol/l at 1 hr PG among those with NGT, impaired fasting glucose (IFG), impaired glucose tolerance (IGT), IFG + IGT, and DM, according to the results of 75 g OGTT. The aim of the present study was to clarify the clinical characteristics of pre-diabetic disorders relating to metabolic syndrome by comparing various parameters including body mass index (BMI), blood levels of various lipids and abdominal wall fat index (AFI) calculated from the thickness of preperitoneal (Pmax) and subcutaneous (Smin) fat layer in the abdomen estimated by ultrasonography with insulin sensitivity determined by homeostatic model assessment (HOMA-IR) in each type of abnormal glucose regulation as classified by PG changes in 75 g OGTT. We also investigated the relationship between insulin secretion capability and insulin sensitivity to delineate the characteristics of each type of abnormal glucose regulation, and compared the area under the insulin curve (AUCins) and the time axis, and the ability of early insulin secretion by glucose loading (insulinogenic index: I.I.) in each type of abnormal glucose regulation. There was a significant positive correlation between HOMA-IR and Smin or Pmax, suggesting that Smin and Pmax may reflect insulin sensitivity. Abdominal obesity, which was diagnosed from the data of AFI, was present in the h-NGT and IFG + IGT groups, suggesting that those groups belong to the clinical entity of metabolic syndrome. HOMA-IR was higher in IFG than in IGT, although I.I. was reduced and AUCins was increased in IFG as well as in IGT. h-NGT demonstrated a slightly lower I.I. and higher AUCins, compared with IGT. IFG demonstrated much stronger insulin resistance than IGT, although I.I. was reduced and AUCins was increased in IFG and IGT. Thus, it is suggested that insulin sensitivity may partly account for the difference in pathogenesis between IFG and IGT; and that h-NGT, which showed abdominal obesity assessed as AFI by ultrasonography, should be recognized as a disease state of metabolic syndrome with impaired glucose regulation.
Iyigundogdu, Ilkin; Derle, Eda; Asena, Leyla; Kural, Feride; Kibaroglu, Seda; Ocal, Ruhsen; Akkoyun, Imren; Can, Ufuk
2018-02-01
Aim To compare the relationship between white matter hyperintensities (WMH) on brain magnetic resonance imaging and retinal nerve fiber layer (RNFL), choroid, and ganglion cell layer (GCL) thicknesses in migraine patients and healthy subjects. We also assessed the role of cerebral hypoperfusion in the formation of these WMH lesions. Methods We enrolled 35 migraine patients without WMH, 37 migraine patients with WMH, and 37 healthy control subjects examined in the Neurology outpatient clinic of our tertiary center from May to December 2015. RFNL, choroid, and GCL thicknesses were measured by optic coherence tomography. Results There were no differences in the RFNL, choroid, or GCL thicknesses between migraine patients with and without WMH ( p > 0.05). Choroid layer thicknesses were significantly lower in migraine patients compared to control subjects ( p < 0.05), while there were no differences in RFNL and GCL thicknesses ( p > 0.05). Conclusions The 'only cerebral hypoperfusion' theory was insufficient to explain the pathophysiology of WMH lesions in migraine patients. In addition, the thinning of the choroid thicknesses in migraine patients suggests a potential causative role for cerebral hypoperfusion and decreased perfusion pressure of the choroid layer.
High efficiency organic photovoltaic cells employing hybridized mixed-planar heterojunctions
Xue, Jiangeng; Uchida, Soichi; Rand, Barry P; Forrest, Stephen
2013-11-19
A device is provided, having a first electrode, a second electrode, and a photoactive region disposed between the first electrode and the second electrode. The photoactive region includes a first organic layer comprising a mixture of an organic acceptor material and an organic donor material, wherein the first organic layer has a thickness not greater than 0.8 characteristic charge transport lengths, and a second organic layer in direct contact with the first organic layer, wherein: the second organic layer comprises an unmixed layer of the organic acceptor material or the organic donor material of the first organic layer, and the second organic layer has a thickness not less than about 0.1 optical absorption lengths. Preferably, the first organic layer has a thickness not greater than 0.3 characteristic charge transport lengths. Preferably, the second organic layer has a thickness of not less than about 0.2 optical absorption lengths. Embodiments of the invention can be capable of power efficiencies of 2% or greater, and preferably 5% or greater.
Effect of layer thickness on the thermal release from Be-D co-deposited layers
NASA Astrophysics Data System (ADS)
Baldwin, M. J.; Doerner, R. P.
2014-08-01
The results of previous work (Baldwin et al 2013 J. Nucl. Mater. 438 S967-70 and Baldwin et al 2014 Nucl. Fusion 54 073005) are extended to explore the influence of layer thickness on the thermal D2 release from co-deposited Be-(0.05)D layers produced at ˜323 K. Bake desorption of layers of thickness 0.2-0.7 µm are explored with a view to examine the influence of layer thickness on the efficacy of the proposed ITER bake procedure, to be carried out at the fixed temperatures of 513 K on the first wall and 623 K in the divertor. The results of experiment and modelling with the TMAP-7 hydrogen transport code, show that thicker Be-D co-deposited layers are relatively more difficult to desorb (time-wise) than thinner layers with the same concentrations of intrinsic traps and retained hydrogen isotope fraction.
A Prospective, Quantitative Evaluation of Fatty Infiltration Before and After Rotator Cuff Repair.
Lansdown, Drew A; Lee, Sonia; Sam, Craig; Krug, Roland; Feeley, Brian T; Ma, C Benjamin
2017-07-01
Current evaluation of muscle fatty infiltration has been limited by subjective classifications. Quantitative fat evaluation through magnetic resonance imaging (MRI) may allow for an improved longitudinal evaluation of the effect of surgical repair on the progression of fatty infiltration. We hypothesized that (1) patients with isolated full-thickness supraspinatus tendon tears would have less progression in fatty infiltration compared with patients with full-thickness tears of multiple tendons and (2) patients with eventual failed repair would have higher baseline levels of fatty infiltration. Cohort study; Level of evidence, 2. Thirty-five patients with full-thickness rotator cuff tears were followed longitudinally. All patients received a shoulder MRI, including the iterative decomposition of echoes of asymmetric length (IDEAL) sequence for fat measurement, prior to surgical treatment and at 6 months after surgical repair. Fat fractions were recorded for all 4 rotator cuff muscles from measurements on 4 sagittal slices centered at the scapular-Y. Demographics and tear characteristics were recorded. Baseline and follow-up fat fractions were compared for patients with isolated supraspinatus tears versus multitendon tears and for patients with intact repairs versus failed repairs. Statistical significance was set at P < .05. The mean fat fractions were significantly higher at follow-up than at baseline for the supraspinatus (9.8% ± 7.0% vs 8.3% ± 5.7%; P = .025) and infraspinatus (7.4% ± 6.1% vs 5.7% ± 4.4%; P = .027) muscles. Patients with multitendon tears showed no significant change for any rotator cuff muscle after repair. Patients with isolated supraspinatus tears showed a significant progression in the supraspinatus fat fraction from baseline to follow-up (from 6.8% ± 4.9% to 8.6% ± 6.8%; P = .0083). Baseline supraspinatus fat fractions were significantly higher in patients with eventual failed repairs compared with those with intact repairs (11.7% ± 6.8% vs 7.1% ± 4.8%; P = .037). Contrary to our initial hypothesis, patients with isolated supraspinatus tears showed a significant progression of fatty infiltration. Patients with eventual repair failure had higher baseline fat fractions in the supraspinatus.
Hayward, M G; Keatinge, W R
1981-01-01
1. The lowest water temperature in which different young adults could stabilize body temperature was found to vary from 32 degrees C to less than 12 degrees C, because of large differences in both total body insulation and metabolic heat production. 2. Total body insulation per unit surface area, in the coldest water allowing stability, was quite closely determined by mean subcutaneous fat thickness measured ultrasonically (r = 0.92), regardless of differences in distribution of this fat between men and women. 3. Reactive individuals developed high metabolic rates, and often rather high insulations in relation to fat thickness, which enabled them to stabilize their body temperatures in water more than 10 degrees C colder than was possible for less reactive individuals of similar fat thickness. 4. Measurements of heat flux, after stabilization in the coldest water possible, showed that the trunk was the main site of heat loss and that over half of the internal insulation there could be accounted for by subcutaneous fat; by contrast, fat could account for less than a third of higher insulations found in muscular parts of the limbs, and for less than 3% of very high insulations in the hands and feet. 5. After stabilization of body temperature at rest in the coldest possible water, exercise reduced internal insulation only in muscular parts of the limbs. Exercise also increased heat loss elsewhere by exposing skin of protected regions such as flexural surfaces of joints. During exercise total heat production increased rather more than heat loss in unreactive subjects, but less than loss in subjects whose heat production had already risen to a high level when they were at rest in cold water. 6. In warm (37 degrees C) water, tissue insulations were lower and much more uniform between subjects and between different body regions than in the cold. Even in the warm, however, insulations remained rather higher in fat than thin subjects, higher at rest than during exercise, and usually higher in the limbs than the upper trunk. PMID:7320937
Ellipsometric study of metal-organic chemically vapor deposited III-V semiconductor structures
NASA Technical Reports Server (NTRS)
Alterovitz, Samuel A.; Sekula-Moise, Patricia A.; Sieg, Robert M.; Drotos, Mark N.; Bogner, Nancy A.
1992-01-01
An ellipsometric study of MOCVD-grown layers of AlGaAs and InGaAs in thick films and strained layer complex structures is presented. It is concluded that the ternary composition of thick nonstrained layers can be accurately determined to within experimental errors using numerical algorithms. In the case of complex structures, thickness of all layers and the alloy composition of nonstrained layers can be determined simultaneously, provided that the correlations between parameters is no higher than 0.9.
Effect of ultrasound-enhanced fat separation on whey powder phospholipid composition and stability.
Torkamani, Amir E; Juliano, Pablo; Fagan, Peter; Jiménez-Flores, Rafael; Ajlouni, Said; Singh, Tanoj K
2016-06-01
Fat from freshly pasteurized liquid whey was partially separated by gravity for 5, 10, and 30min, with and without simultaneous application of ultrasound. Ultrasound treatments were carried out at 400 and 1,000 kHz at different specific energy inputs (23-390 kJ/kg). The fat-enriched top layers (L1) and the fat-depleted bottom layers (L2) were separately removed and freeze-dried. Nonsonicated and sonicated L2 powders were stored for 14d at ambient temperature to assess their oxidative stability. Creaming was enhanced at both frequencies and fat separation increased with higher ultrasonic energy, extended sonication, or both. The oxidative volatile compound content decreased in defatted whey powders below published odor detection threshold values for all cases. Sonication had a minor influence on the partitioning of phospholipids with fat separation. The current study suggested that ultrasonication at high frequency enhanced fat separation from freshly pasteurized whey while improving whey powder oxidative stability. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Method and apparatus for determining fat content of tissue
Weber, Thomas M.; Spletzer, Barry L.; Bryan, Jon R.; Dickey, Fred M.; Shagam, Richard N.; Gooris, Luc
2001-01-01
A method and apparatus for determining characteristics of tissue is disclosed. The method comprises supplying optical energy to a tissue and detecting at a plurality of locations consequent energy scattered by the tissue. Analysis of the scattered energy as taught herein provides information concerning the properties of the tissue, specifically information related to the fat and lean content and thickness of the tissue. The apparatus comprises a light source adapted to deliver optical energy to a tissue. A plurality of detectors can be mounted at different positions relative to the source to detect energy scattered by the tissue. A signal processor as taught herein can determine characteristics of the tissue from the signals from the detectors and locations of the detectors, specifically information related to the fat and lean content and thickness of the tissue.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ye, W. H.; He, X. T.; CAPT, Peking University, Beijing 100871
2011-02-15
In this research, competitions between Rayleigh-Taylor instability (RTI) and Kelvin-Helmholtz instability (KHI) in two-dimensional incompressible fluids within a linear growth regime are investigated analytically. Normalized linear growth rate formulas for both the RTI, suitable for arbitrary density ratio with continuous density profile, and the KHI, suitable for arbitrary density ratio with continuous density and velocity profiles, are obtained. The linear growth rates of pure RTI ({gamma}{sub RT}), pure KHI ({gamma}{sub KH}), and combined RTI and KHI ({gamma}{sub total}) are investigated, respectively. In the pure RTI, it is found that the effect of the finite thickness of the density transition layermore » (L{sub {rho}}) reduces the linear growth of the RTI (stabilizes the RTI). In the pure KHI, it is found that conversely, the effect of the finite thickness of the density transition layer increases the linear growth of the KHI (destabilizes the KHI). It is found that the effect of the finite thickness of the density transition layer decreases the ''effective'' or ''local'' Atwood number (A) for both the RTI and the KHI. However, based on the properties of {gamma}{sub RT}{proportional_to}{radical}(A) and {gamma}{sub KH}{proportional_to}{radical}(1-A{sup 2}), the effect of the finite thickness of the density transition layer therefore has a completely opposite role on the RTI and the KHI noted above. In addition, it is found that the effect of the finite thickness of the velocity shear layer (L{sub u}) stabilizes the KHI, and for the most cases, the combined effects of the finite thickness of the density transition layer and the velocity shear layer (L{sub {rho}=}L{sub u}) also stabilize the KHI. Regarding the combined RTI and KHI, it is found that there is a competition between the RTI and the KHI because of the completely opposite effect of the finite thickness of the density transition layer on these two kinds of instability. It is found that the competitions between the RTI and the KHI depend, respectively, on the Froude number, the density ratio of the light fluid to the heavy one, and the finite thicknesses of the density transition layer and the velocity shear layer. Furthermore, for the fixed Froude number, the linear growth rate ratio of the RTI to the KHI decreases with both the density ratio and the finite thickness of the density transition layer, but increases with the finite thickness of the velocity shear layer and the combined finite thicknesses of the density transition layer and the velocity shear layer (L{sub {rho}=}L{sub u}). In summary, our analytical results show that the effect of the finite thickness of the density transition layer stabilizes the RTI and the overall combined effects of the finite thickness of the density transition layer and the velocity shear layer (L{sub {rho}=}L{sub u}) also stabilize the KHI. Thus, it should be included in applications where the transition layer effect plays an important role, such as the formation of large-scale structures (jets) in high energy density physics and astrophysics and turbulent mixing.« less
Strong Effect of Azodye Layer Thickness on RM-Stabilized Photoalignment
2017-05-21
to thicker layers (~40 nm). Author Keywords photoalignment; azodye; reactive mesogen 1. Introduction Photoalignment of liquid crystals by azodye...Polymerizable azodyes[3] as well as passivation of the azodye film by spin-coating with a layer of reactive mesogen[4] are currently proposed solutions...thick alignment film rather than a ~40 nm thick alignment film ; cells with thin alignment layers are stable to exposure to polarized light for at
NASA Astrophysics Data System (ADS)
Odagawa, Hiroyuki; Terada, Koshiro; Tanaka, Yohei; Nishikawa, Hiroaki; Yanagitani, Takahiko; Cho, Yasuo
2017-10-01
A quantitative measurement method for a polarity-inverted layer in ferroelectric or piezoelectric thin film is proposed. It is performed nondestructively by scanning nonlinear dielectric microscopy (SNDM). In SNDM, linear and nonlinear dielectric constants are measured using a probe that converts the variation of capacitance related to these constants into the variation of electrical oscillation frequency. In this paper, we describe a principle for determining the layer thickness and some calculation results of the output signal, which are related to the radius of the probe tip and the thickness of the inverted layer. Moreover, we derive an equation that represents the relationship between the output signal and the oscillation frequency of the probe and explain how to determine the thickness from the measured frequency. Experimental results in Sc-doped AlN piezoelectric thin films that have a polarity-inverted layer with a thickness of 1.5 µm fabricated by radio frequency magnetron sputtering showed a fairly good value of 1.38 µm for the thickness of the polarity-inverted layer.
Work Function Variations in Twisted Graphene Layers
Robinson, Jeremy T.; Culbertson, James; Berg, Morgann; ...
2018-01-31
By combining optical imaging, Raman spectroscopy, kelvin probe force microscopy (KFPM), and photoemission electron microscopy (PEEM), we show that graphene’s layer orientation, as well as layer thickness, measurably changes the surface potential (Φ). Detailed mapping of variable-thickness, rotationally-faulted graphene films allows us to correlate Φ with specific morphological features. Using KPFM and PEEM we measure ΔΦ up to 39 mV for layers with different twist angles, while ΔΦ ranges from 36–129 mV for different layer thicknesses. The surface potential between different twist angles or layer thicknesses is measured at the KPFM instrument resolution of ≤ 200 nm. The PEEM measuredmore » work function of 4.4 eV for graphene is consistent with doping levels on the order of 10 12cm -2. Here, we find that Φ scales linearly with Raman G-peak wavenumber shift (slope = 22.2 mV/cm -1) for all layers and twist angles, which is consistent with doping-dependent changes to graphene’s Fermi energy in the ‘high’ doping limit. Our results here emphasize that layer orientation is equally important as layer thickness when designing multilayer two-dimensional systems where surface potential is considered.« less
Crystallization of silicon-germanium by aluminum-induced layer exchange
NASA Astrophysics Data System (ADS)
Isomura, Masao; Yajima, Masahiro; Nakamura, Isao
2018-02-01
We have studied the crystallization of amorphous silicon-germanium (a-SiGe) by aluminum (Al)-induced layer exchange (ALILE) with a starting structure of glass/Al/Al oxide/a-SiGe. We examined ALILE at 450 °C, which is slightly higher than the eutectic temperature of Ge and Al, in order to shorten the ALILE time. We successfully produced c-SiGe films oriented in the (111) direction for 16 h without significant alloying. The thickness of Al layers should be 2800 Å or more to complete the ALILE for the a-SiGe layers of 2000-2800 Å thickness. When the Al layer is as thick as the a-SiGe layer, almost uniform c-SiGe is formed on the glass substrate. On the other hand, the islands of c-SiGe are formed on the glass substrate when the Al layer is thicker than the a-SiGe layer. The islands become smaller with thicker Al layers because more excess Al remains between the SiGe islands. The results indicate that the configuration of c-SiGe can be altered from a uniform structure to island structures of various sizes by changing the ratio of a-SiGe thickness to Al thickness.
Work Function Variations in Twisted Graphene Layers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, Jeremy T.; Culbertson, James; Berg, Morgann
By combining optical imaging, Raman spectroscopy, kelvin probe force microscopy (KFPM), and photoemission electron microscopy (PEEM), we show that graphene’s layer orientation, as well as layer thickness, measurably changes the surface potential (Φ). Detailed mapping of variable-thickness, rotationally-faulted graphene films allows us to correlate Φ with specific morphological features. Using KPFM and PEEM we measure ΔΦ up to 39 mV for layers with different twist angles, while ΔΦ ranges from 36–129 mV for different layer thicknesses. The surface potential between different twist angles or layer thicknesses is measured at the KPFM instrument resolution of ≤ 200 nm. The PEEM measuredmore » work function of 4.4 eV for graphene is consistent with doping levels on the order of 10 12cm -2. Here, we find that Φ scales linearly with Raman G-peak wavenumber shift (slope = 22.2 mV/cm -1) for all layers and twist angles, which is consistent with doping-dependent changes to graphene’s Fermi energy in the ‘high’ doping limit. Our results here emphasize that layer orientation is equally important as layer thickness when designing multilayer two-dimensional systems where surface potential is considered.« less
Ackermann, Philipp; Brachert, Maike; Albrecht, Philipp; Ringelstein, Marius; Finis, David; Geerling, Gerd; Aktas, Orhan; Guthoff, Rainer
2017-07-01
A characteristic disease pattern may be reflected by retinal layer thickness changes in non-arteritic anterior ischaemic optic neuropathy measured using spectraldomain optical coherence tomography. Retinal layer segmentation is enabled by advanced software. In this study, retinal layer thicknesses in acute and chronic non-arteritic anterior ischaemic optic neuropathy were compared. A single-centre cross-sectional analysis was used. A total of 27 patients (20 age-matched healthy eyes) were included: 14 with acute (<7 days) and 13 patients with chronic non-arteritic anterior ischaemic optic neuropathy. Macular volume and 12° peripapillary ring optical coherence tomography scans were used. The peripapillary thicknesses of the following layers were determined by manual segmentation: retinal nerve fibres, ganglion cells + inner plexiform layer, inner nuclear layer + outer plexiform layer, outer nuclear layer + inner segments of the photoreceptors and outer segments of the photoreceptors to Bruch's membrane. Macular retinal layer thicknesses were automatically determined in volume cubes centred on the fovea. Peripapillary retinal swelling in acute nonarteritic anterior ischaemic optic neuropathy was attributable to retinal nerve fibre layer, ganglion cell layer/inner plexiform layer and outer nuclear layer/segments of the photoreceptors thickening. In chronic cases, peripapillary retinal nerve fibre layer, macular ganglion cell layer and inner plexiform layer thinning were observed. In acute non-arteritic anterior ischaemic optic neuropathy, the inner and outer peripapillary retinal layers are affected by thickness changes. In chronic cases, atrophy of the ganglion cells and their axons and dendrites is evident by inner retinal layer thinning. © 2017 Royal Australian and New Zealand College of Ophthalmologists.
Rani, Anupama; Sharma, Vivek; Arora, Sumit; Lal, Darshan; Kumar, Anil
2015-04-01
Detection of milk fat adulteration with foreign fats/oils continues to be a challenge for the dairy industry as well as food testing laboratories, especially in the present scenario of rampant adulteration using the scientific knowledge by unscrupulous persons involved in the trade. In the present investigation a rapid reversed-phase thin layer chromatographic (RP-TLC) protocol was standardized to ascertain the purity of milk fat. RP-TLC protocol did not show any false positive results in the genuine ghee (clarified butter fat) samples of known origin. Adulteration of ghee with coconut oil up to 7. 5 %, soybean oil, sunflower oil and groundnut oil up to 1 %, while, designer oil up to 2 % level could be detected using the standardized RP-TLC protocol. The protocol standardized is rapid and convenient to use.
Abdellatif, Mona K; Fouad, Mohamed M
2018-03-01
To investigate the factors in migraine that have the highest significance on retinal and choroidal layers' thickness. Ninety patients with migraine and 40 age-matched healthy participants were enrolled in this observational, cross-sectional study. After full ophthalmological examination, spectral domain-optical coherence tomography was done for all patients measuring the thickness of ganglion cell layer and retinal nerve fiber layer. Enhanced depth imaging technique was used to measure the choroidal thickness. There was significant thinning in the superior and inferior ganglion cell layers, all retinal nerve fiber layer quadrants, and all choroidal quadrants (except for the central subfield) in migraineurs compared to controls. The duration of migraine was significantly correlated with ganglion cell layer, retinal nerve fiber layer, and all choroidal quadrants, while the severity of migraine was significantly correlated with ganglion cell layer and retinal nerve fiber layer only. Multiregression analysis showed that the duration of migraine is the most important determinant factor of the superior retinal nerve fiber layer quadrant (β = -0.375, p = 0.001) and in all the choroidal quadrants (β = -0.531, -0.692, -0.503, -0.461, -0.564, respectively, p < 0.001), while severity is the most important determinant factor of inferior, nasal, and temporal retinal nerve fiber layer quadrants (β = -0.256, -0.335, -0.308; p = 0.036, 0.005, 0.009, respectively) and the inferior ganglion cell layer hemisphere (β = -0.377 and p = 0.001). Ganglion cell layer, retinal nerve fiber layer, and choroidal thickness are significantly thinner in patients with migraine. The severity of migraine has more significant influence in the thinning of ganglion cell layer and retinal nerve fiber layer, while the duration of the disease affected the choroidal thickness more.
Broadband operation of rolled-up hyperlenses
NASA Astrophysics Data System (ADS)
Schwaiger, Stephan; Rottler, Andreas; Bröll, Markus; Ehlermann, Jens; Stemmann, Andrea; Stickler, Daniel; Heyn, Christian; Heitmann, Detlef; Mendach, Stefan
2012-06-01
This work is related to an earlier publication [Schwaiger , Phys. Rev. Lett.PRLTAO0031-900710.1103/PhysRevLett.102.163903 102, 163903 (2009)], where we demonstrated by means of fiber-based transmission measurements that rolled-up Ag-(In)GaAs multilayers represent three-dimensional metamaterials with a plasma edge which is tunable over the visible and near-infrared regime by changing the thickness ratio of Ag and (In)GaAs, and predicted by means of finite-difference time-domain simulations that hyperlensing occurs at this frequency-tunable plasma edge. In the present work we develop a method to measure reflection curves on these structures and find that they correspond to the same tunable plasma edge. We find that retrieving the effective parameters from transmission and reflection data fails, because our realized metamaterials exceed the single-layer thicknesses of 5nm, which we analyze to be the layer thickness limit for the applicability of effective parameter retrieval. We show that our realized structures nevertheless have the functionality of an effective metamaterial by supplying a detailed finite-difference time-domain study which compares light propagation through our realized structure (17-nm-thick Ag layers and 34-nm-thick GaAs layers) and light propagation through an idealized structure of the same total thickness but with very thin layers [2-nm-thick Ag layers and 4-nm-thick (In)GaAs layers]. In particular, our simulations predict broadband hyperlensing covering a large part of the visible spectrum for both the idealized and our realized structures.
Li, Song-Lin; Miyazaki, Hisao; Song, Haisheng; Kuramochi, Hiromi; Nakaharai, Shu; Tsukagoshi, Kazuhito
2012-08-28
We demonstrate the possibility in quantifying the Raman intensities for both specimen and substrate layers in a common stacked experimental configuration and, consequently, propose a general and rapid thickness identification technique for atomic-scale layers on dielectric substrates. Unprecedentedly wide-range Raman data for atomically flat MoS(2) flakes are collected to compare with theoretical models. We reveal that all intensity features can be accurately captured when including optical interference effect. Surprisingly, we find that even freely suspended chalcogenide few-layer flakes have a stronger Raman response than that from the bulk phase. Importantly, despite the oscillating intensity of specimen spectrum versus thickness, the substrate weighted spectral intensity becomes monotonic. Combined with its sensitivity to specimen thickness, we suggest this quantity can be used to rapidly determine the accurate thickness for atomic layers.
Wasyluk, Jaromir T; Jankowska-Lech, Irmina; Terelak-Borys, Barbara; Grabska-Liberek, Iwona
2012-03-01
We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. Study subjects had advanced primary open-angle glaucoma, previously treated conservatively, diagnosed and confirmed by additional examinations (visual field, ophthalmoscopy of optic nerve, gonioscopy), A total of 10 patients were enrolled (9 women and 1 man), aged 18-70 years of age. Nineteen eyes with advanced glaucomatous neuropathy were examined. 1) Performing a threshold perimetry Octopus, G2 strategy and ophthalmoscopy of optic nerve to confirm the presence of advanced primary open-angle glaucoma; 2) performing a GDx VCC scanning laser polarimetry of retinal nerve fibre layer; 3) measuring the retinal nerve fibre layer thickness with 3 different optical coherence tomographs. The parameters of the retinal nerve fibre layer thickness are highly correlated between the GDx and OCT Stratus and 3D OCT-1000 devices in mean retinal nerve fibre layer thickness, retinal nerve fibre layer thickness in the upper sector, and correlation of NFI (GDx) with mean retinal nerve fibre layer thickness in OCT examinations. Absolute values of the retinal nerve fibre layer thickness (measured in µm) differ significantly between GDx and all OCT devices. Examination with OCT devices is a sensitive diagnostic method of glaucoma, with good correlation with the results of GDx scanning laser polarimetry of the patients.
NASA Astrophysics Data System (ADS)
Silvayeh, Zahra; Vallant, Rudolf; Sommitsch, Christof; Götzinger, Bruno; Karner, Werner; Hartmann, Matthias
2017-11-01
Hybrid components made of aluminum alloys and high-strength steels are typically used in automotive lightweight applications. Dissimilar joining of these materials is quite challenging; however, it is mandatory in order to produce multimaterial car body structures. Since especially welding of tailored blanks is of utmost interest, single-sided Cold Metal Transfer butt welding of thin sheets of aluminum alloy EN AW 6014 T4 and galvanized dual-phase steel HCT 450 X + ZE 75/75 was experimentally investigated in this study. The influence of different filler alloy compositions and welding process parameters on the thickness of the intermetallic layer, which forms between the weld seam and the steel sheet, was studied. The microstructures of the weld seam and of the intermetallic layer were characterized using conventional optical light microscopy and scanning electron microscopy. The results reveal that increasing the heat input and decreasing the cooling intensity tend to increase the layer thickness. The silicon content of the filler alloy has the strongest influence on the thickness of the intermetallic layer, whereas the magnesium and scandium contents of the filler alloy influence the cracking tendency. The layer thickness is not uniform and shows spatial variations along the bonding interface. The thinnest intermetallic layer (mean thickness < 4 µm) is obtained using the silicon-rich filler Al-3Si-1Mn, but the layer is more than twice as thick when different low-silicon fillers are used.
NASA Astrophysics Data System (ADS)
Goto, Takeyoshi; Kinugasa, Tomoya
2018-05-01
The first electronic transition (A˜ ← X˜) and the hydrogen bonding state of an ultra-thin water layer of nanometer thickness between two α-alumina surfaces (0.5-20 nm) were studied using far-ultraviolet (FUV) spectroscopy in the wavelength range 140-180 nm. The ultra-thin water layer of nanometer thickness was prepared by squeezing a water droplet ( 1 μL) between a highly polished α-alumina prism and an α-alumina plate using a high pressure clamp ( 4.7 MPa), and the FUV spectra of the water layer at different thicknesses were measured using the attenuated total reflection method. As the water layer became thinner, the A˜ ← X˜ bands were gradually shifted to higher or lower energy relative to that of bulk water; at thicknesses smaller than 4 nm, these shifts were substantial (0.1-0.2 eV) in either case. The FUV spectra of the water layer with thickness < 4 nm indicate the formation of structured ice-like hydrogen bond (H-bond) layers for the higher energy shifts or the formation of slightly weaker H-bond layers as compared to those in the bulk liquid state for lower energy shifts. In either case, the H-bond structure of bulk liquid water is nearly lost at thicknesses below 4 nm, because of steric hydration forces between the α-alumina surfaces.
NASA Astrophysics Data System (ADS)
Hohenberger, S.; Lazenka, V.; Temst, K.; Selle, S.; Patzig, C.; Höche, T.; Grundmann, M.; Lorenz, M.
2018-05-01
The effect of double-layer thickness and partial substitution of Bi3+ by Gd3+ is demonstrated for multiferroic BaTiO3–BiFeO3 2–2 heterostructures. Multilayers of 15 double layers of BaTiO3 and Bi0.95Gd0.05FeO3 were deposited onto (0 0 1) oriented SrTiO3 substrates by pulsed laser deposition with various double layer thicknesses. X-ray diffraction and high resolution transmission electron microscopy investigations revealed a systematic strain tuning with layer thickness via coherently strained interfaces. The multilayers show increasingly enhanced magnetoelectric coupling with reduced double layer thickness. The maximum magnetoelectric coupling coefficient was measured to be as high as 50.8 V cm‑1 Oe‑1 in 0 T DC bias magnetic field at room temperature, and 54.9 V cm‑1 Oe‑1 above 3 T for the sample with the thinnest double layer thickness of 22.5 nm. This enhancement is accompanied by progressively increasing perpendicular magnetic anisotropy and compressive out-of-plane strain. To understand the origin of the enhanced magnetoelectric coupling in such multilayers, the temperature and magnetic field dependency of is discussed. The magnetoelectric performance of the Gd3+ substituted samples is found to be slightly enhanced when compared to unsubstituted BaTiO3–BiFeO3 multilayers of comparable double-layer thickness.
Do South Indian newborn babies have higher fat percentage for a given birth weight?
Kv, Radha Krishna; Hemalatha, Rajkumar; Mamidi, Raja Sriswan; Jj, Babu Geddam; Balakrishna, N
2016-05-01
India is experiencing rapidly escalating epidemics of diabetes and cardiovascular disease. High fat percent in Indian adults may have its origins at birth (Fetal origin hypothesis). Conflicting evidence from India have shown increased or similar fat mass in Indian newborn babies compared to western countries. To compare body composition of term infants with data from similar studies in India and developed countries. Cross-sectional study in newborn infants at the antenatal ward of a tertiary care hospital in South India. 626 mothers and their newborn babies. Maternal body weight and height, baby weight, length, head circumference, skin folds at three sites. Body fat, arm muscle area and arm muscle index were calculated based on known methods. Mean (SD) birth weight of newborn babies was 2.80 (0.37) kg and 43% of them were small for gestational age. Birth weight was significantly related to subscapular (r=0.445; p<0.001) and triceps (r=0.567; p<0.001) skin fold thickness. Mean (CI) Subscapular skin fold thickness and total body fat % was 3.81mm (3.74-3.97) and 10.5% (10.2-10.8). Mean total body fat % for small for gestational age (SGA) (9.57%) was significantly lower than appropriate for gestational age (AGA) babies (11.7%). The mean body fat percent in AGA infants was similar to that of studies reported on term infants of developed countries, suggesting that South Indian babies may accumulate similar fat mass with increasing birth weight and gestational age. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Thermal release of D2 from new Be-D co-deposits on previously baked co-deposits
NASA Astrophysics Data System (ADS)
Baldwin, M. J.; Doerner, R. P.
2015-12-01
Past experiments and modeling with the TMAP code in [1, 2] indicated that Be-D co-deposited layers are less (time-wise) efficiently desorbed of retained D in a fixed low-temperature bake, as the layer grows in thickness. In ITER, beryllium rich co-deposited layers will grow in thickness over the life of the machine. Although, compared with the analyses in [1, 2], ITER presents a slightly different bake efficiency problem because of instances of prior tritium recover/control baking. More relevant to ITER, is the thermal release from a new and saturated co-deposit layer in contact with a thickness of previously-baked, less-saturated, co-deposit. Experiments that examine the desorption of saturated co-deposited over-layers in contact with previously baked under-layers are reported and comparison is made to layers of the same combined thickness. Deposition temperatures of ∼323 K and ∼373 K are explored. It is found that an instance of prior bake leads to a subtle effect on the under-layer. The effect causes the thermal desorption of the new saturated over-layer to deviate from the prediction of the validated TMAP model in [2]. Instead of the D thermal release reflecting the combined thickness and levels of D saturation in the over and under layer, experiment differs in that, i) the desorption is a fractional superposition of desorption from the saturated over-layer, with ii) that of the combined over and under -layer thickness. The result is not easily modeled by TMAP without the incorporation of a thin BeO inter-layer which is confirmed experimentally on baked Be-D co-deposits using X-ray micro-analysis.
Nuutila, Kristo; Singh, Mansher; Kruse, Carla; Eriksson, Elof
2017-08-01
Epidermal stem cells present in the skin appendages of the dermis might be crucial in wound healing. In this study, the authors located these cells in the dermis and evaluated their contribution to full-thickness wound healing in a porcine model. Four sequentially deeper 0.35-mm-thick skin grafts were harvested from the same donor site going down to 1.4 mm in depth (layers 1 through 4). The layers were minced to 0.8 × 0.8 × 0.35-mm micrografts and transplanted (1:2) onto full-thickness porcine wounds. Healing was monitored up to 28 days and biopsy specimens were collected on days 6 and 10. Multiple wound healing parameters were used to assess the quality of healing. The authors' results showed that wounds transplanted with layer 2 (0.35 to 0.7 mm) and layer 3 (0.7 to 1.05 mm) micrografts demonstrated reepithelialization rates comparable to that of split-thickness skin graft (layer 1, 0.00 to 0.35 mm; split-thickness skin graft) at day 10. At day 28, dermal micrografts (layers 2 and 3) showed quality of healing comparable to that of split-thickness skin grafts (layer 1) in terms of wound contraction and scar elevation index. The amounts of epidermal stem cells [cluster of differentiation (CD) 34] and basal keratinocytes (KRT14) at each layer were quantified by immunohistochemistry. The analysis showed that layers 2 and 3 contained the most CD34 cells and layer 1 was the richest in KRT14 cells. The immunohistochemistry also indicated that, by day 6, CD34 cells had differentiated into KRT14 cells, which migrated from the grafts and contributed to the reepithelialization of the wound.
Miao, Cuilian; Chen, Shaoguang; Ding, Jingzhong; Liu, Kiang; Li, Debiao; Macedo, Robson; Lai, Shenghan; Vogel-Claussen, Jens; Brown, Elizabeth R.; Lima, João A. C.
2011-01-01
Purpose: To determine the relationship of pericardial fat, which secretes proinflammatory markers that have been implicated in coronary atherosclerosis, with atherosclerotic plaque in an asymptomatic population–based cohort. Materials and Methods: In this institutional review board–approved study, all participants supplied written informed consent. One hundred eighty-three participants (89 women, 94 men; mean age, 61 years ± 9 [standard deviation]) from the community-based Multi-Ethnic Study of Atherosclerosis (MESA) were included. The coronary artery eccentricity (ratio of maximal to minimal coronary artery wall thickness) was determined by using magnetic resonance (MR) imaging and served as an index of plaque burden. The pericardial fat volume was determined by using computed tomography. Linear regression coefficient analysis was used to correlate pericardial fat volume with coronary artery wall thickness and plaque eccentricity. Results: Pericardial fat volume correlated significantly with degree of plaque eccentricity (P < .05) in both men and women. After adjustments for body mass index (BMI) and waist circumference, traditional risk factors, C-reactive protein level, and coronary artery calcium content, the relationship between pericardial fat and plaque eccentricity remained significant in men (P < .01) but not in women. BMI and waist circumference correlated with degree of plaque eccentricity in the univariate model (P < .05) but not after adjustment for pericardial fat volume or traditional risk factors. Conclusion: Pericardial fat volume, rather than BMI and waist circumference, was more strongly related to plaque eccentricity as a measure of coronary atherosclerotic plaque burden. The results support the proposed role of pericardial fat in association with atherosclerosis. © RSNA, 2011 PMID:21846753
NASA Astrophysics Data System (ADS)
Zhang, Le; Taguchi, Dai; Manaka, Takaaki; Iwamoto, Mitsumasa
2013-05-01
By using current-voltage (I-V) measurements and optical modulation spectroscopy, we investigated the dependence of the carrier behaviour on the film thickness of the buried pentacene layer in C60/pentacene ambipolar double-layer organic field-effect transistors (OFETs). It was found that the buried pentacene layer not only acted as a hole transport layer, but also accounted for the properties of the C60/pentacene interface. The hole and electron behaviour exhibited different thickness dependence on the buried pentacene layer, implying the presence of the spatially separated conduction paths. It was suggested that the injected holes transported along the pentacene/gate dielectric interface, which were little affected by the buried pentacene layer thickness or the upper C60 layer; while, the injected electrons accumulated at the C60/pentacene interface, which were sensitive to the interfacial conditions or the buried pentacene layer. Furthermore, it was suggested that the enhanced surface roughness of the buried pentacene layer was responsible for the observed electron behaviour, especially when dpent>10 nm.
Loesaus, Julia; Wobbe, Isabel; Stahlberg, Erik; Barkhausen, Joerg; Goltz, Jan Peter
2017-09-28
To evaluate the reliability of pronator quadratus fat pad sign to detect distal radius fracture and to predict its severity. Retrospectively we identified 89 consecutive patients (41 female, mean age 49 ± 18 years) who had X-ray (CR) and computed tomography (CT) within 24 h following distal forearm trauma. Thickness of pronator quadratus fat pad complex (PQC) was measured using lateral views (CR) and sagittal reconstructions (CT). Pearson's test was used to determine the correlation of the PQC thickness in CR and CT. A positive pronator quadratus sign (PQS) was defined as a PQC > 8.0 mm (female) or > 9.0 mm (male). Frykman classification was utilized to assess the severity of fractures. Forty-four/89 patients (49%) had a distal radius fracture (Frykman I n = 3, II n = 0, III n = 10, IV n = 5, V n = 2, VI n = 2, VII n = 9, VIII n = 13). Mean thickness of the PQC thickness can reliably be measured on X-ray views and was 7.5 ± 2.8 mm in lateral views (CR), respectively 9.4 ± 3.0 mm in sagittal reconstructions (CT), resulting in a significant correlation coefficient of 0.795. A positive PQS at CR was present in 21/44 patients (48%) with distal radius fracture and in 2/45 patients (4%) without distal radius fracture, resulting in a specificity of 96% and a sensitivity of 48% for the detection of distal radius fractures. There was no correlation between thickness of the PQC and severity of distal radius fractures. A positive PQS shows high specificity but low sensitivity for detection of distal radius fractures. The PQC thickness cannot predict the severity of distal radius fractures.
Loesaus, Julia; Wobbe, Isabel; Stahlberg, Erik; Barkhausen, Joerg; Goltz, Jan Peter
2017-01-01
AIM To evaluate the reliability of pronator quadratus fat pad sign to detect distal radius fracture and to predict its severity. METHODS Retrospectively we identified 89 consecutive patients (41 female, mean age 49 ± 18 years) who had X-ray (CR) and computed tomography (CT) within 24 h following distal forearm trauma. Thickness of pronator quadratus fat pad complex (PQC) was measured using lateral views (CR) and sagittal reconstructions (CT). Pearson’s test was used to determine the correlation of the PQC thickness in CR and CT. A positive pronator quadratus sign (PQS) was defined as a PQC > 8.0 mm (female) or > 9.0 mm (male). Frykman classification was utilized to assess the severity of fractures. RESULTS Forty-four/89 patients (49%) had a distal radius fracture (Frykman I n = 3, II n = 0, III n = 10, IV n = 5, V n = 2, VI n = 2, VII n = 9, VIII n = 13). Mean thickness of the PQC thickness can reliably be measured on X-ray views and was 7.5 ± 2.8 mm in lateral views (CR), respectively 9.4 ± 3.0 mm in sagittal reconstructions (CT), resulting in a significant correlation coefficient of 0.795. A positive PQS at CR was present in 21/44 patients (48%) with distal radius fracture and in 2/45 patients (4%) without distal radius fracture, resulting in a specificity of 96% and a sensitivity of 48% for the detection of distal radius fractures. There was no correlation between thickness of the PQC and severity of distal radius fractures. CONCLUSION A positive PQS shows high specificity but low sensitivity for detection of distal radius fractures. The PQC thickness cannot predict the severity of distal radius fractures. PMID:29098069
Thickness-dependent electron mobility of single and few-layer MoS{sub 2} thin-film transistors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Ji Heon; Kim, Tae Ho; Lee, Hyunjea
We investigated the dependence of electron mobility on the thickness of MoS{sub 2} nanosheets by fabricating bottom-gate single and few-layer MoS{sub 2} thin-film transistors with SiO{sub 2} gate dielectrics and Au electrodes. All the fabricated MoS{sub 2} transistors showed on/off-current ratio of ∼10{sup 7} and saturated output characteristics without high-k capping layers. As the MoS{sub 2} thickness increased from 1 to 6 layers, the field-effect mobility of the fabricated MoS{sub 2} transistors increased from ∼10 to ∼18 cm{sup 2}V{sup −1}s{sup −1}. The increased subthreshold swing of the fabricated transistors with MoS{sub 2} thickness suggests that the increase of MoS{sub 2}more » mobility with thickness may be related to the dependence of the contact resistance and the dielectric constant of MoS{sub 2} layer on its thickness.« less
USDA-ARS?s Scientific Manuscript database
The effects of 2 levels of supplemental dietary poultry fat (PF) and the combination of PF, phytase (PHY) and 25-hydroxycholecalciferol (D3) on the performance of commercial layers inoculated with F-strain Mycoplasma gallisepticum (FMG) were investigated in 2 trials. Sham and FMG inoculations were ...
Solid oxide fuel cell cathode with oxygen-reducing layer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Surdoval, Wayne A.; Berry, David A.; Shultz, Travis
The disclosure provides a SOFC comprised of an electrolyte, anode, and cathode, where the cathode comprises an MIEC and an oxygen-reducing layer. The oxygen-reducing layer is in contact with the MIEC, and the MIEC is generally between and separating the oxygen-reducing layer and the electrolyte. The oxygen-reducing layer is comprised of single element oxides, single element carbonates, or mixtures thereof, and has a thickness of less than about 30 nm. In a particular embodiment, the thickness is less than 5 nm. In another embodiment, the thickness is about 3 monolayers or less. The oxygen-reducing layer may be a continuous filmmore » or a discontinuous film with various coverage ratios. The oxygen-reducing layer at the thicknesses described may be generated on the MIEC surface using means known in the art such as, for example, ALD processes.« less
Pane, Epita S; Palamara, Joseph E A; Messer, Harold H
2015-12-01
This study aims to evaluate tensile and shear bond strengths of one epoxy (AH) and two methacrylate resin-based sealers (EZ and RS) in thin and thick layers bonded to root dentine. An alignment device was prepared for accurate positioning of 20 root dentine cylinders in a predefined gap of 0.1 or 1 mm. Sealer was placed in the interface. Bond strength tests were conducted. Mode of failures and representative surfaces were evaluated. Data were analysed using anova and post-hoc tests, with P < 0.05. The thick layer of sealer produced higher bond strength, except for the shear bond strength of EZ. Significant differences between thin and thick layers were found only in tensile bond strengths of AH and RS. Mixed type of failure was constantly found with all sealers. Bond strengths of thick layers of resin-based sealers to root dentine tended to be higher than with thin layers. © 2015 Australian Society of Endodontology.
Nieves-Moreno, María; Martínez-de-la-Casa, José M; Bambo, María P; Morales-Fernández, Laura; Van Keer, Karel; Vandewalle, Evelien; Stalmans, Ingeborg; García-Feijoó, Julián
2018-02-01
This study examines the capacity to detect glaucoma of inner macular layer thickness measured by spectral-domain optical coherence tomography (SD-OCT) using a new normative database as the reference standard. Participants ( N = 148) were recruited from Leuven (Belgium) and Zaragoza (Spain): 74 patients with early/moderate glaucoma and 74 age-matched healthy controls. One eye was randomly selected for a macular scan using the Spectralis SD-OCT. The variables measured with the instrument's segmentation software were: macular nerve fiber layer (mRNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) volume and thickness along with circumpapillary RNFL thickness (cpRNFL). The new normative database of macular variables was used to define the cutoff of normality as the fifth percentile by age group. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) of each macular measurement and of cpRNFL were used to distinguish between patients and controls. Overall sensitivity and specificity to detect early-moderate glaucoma were 42.2% and 88.9% for mRNFL, 42.4% and 95.6% for GCL, 42.2% and 94.5% for IPL, and 53% and 94.6% for RNFL, respectively. The best macular variable to discriminate between the two groups of subjects was outer temporal GCL thickness as indicated by an AUROC of 0.903. This variable performed similarly to mean cpRNFL thickness (AUROC = 0.845; P = 0.29). Using our normative database as reference, the diagnostic power of inner macular layer thickness proved comparable to that of peripapillary RNFL thickness. Spectralis SD-OCT, cpRNFL thickness, and individual macular inner layer thicknesses show comparable diagnostic capacity for glaucoma and RNFL, GCL, and IPL thickness may be useful as an alternative diagnostic test when the measure of cpRNFL shows artifacts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pathak, S.; Li, N.; Maeder, X.
We investigated the mechanical response of physical vapor deposited Cu–TiN nanolayered composites of varying layer thicknesses from 5 nm to 200 nm. Both the Cu and TiN layers were found to consist of single phase nanometer sized grains. The grain sizes in the Cu and TiN layers, measured using transmission electron microscopy and X-ray diffraction, were found to be comparable to or smaller than their respective layer thicknesses. Indentation hardness testing revealed that the hardness of such nanolayered composites exhibits a weak dependence on the layer thickness but is more correlated to their grain size.
Hao, Liang
2014-01-01
In situ reaction was activated in the powder mixture of Al/5 wt.%Fe2O3 by using selective laser melting (SLM) to directly fabricate aluminium metal matrix composite parts. The microstructural characteristics of these in situ consolidated parts through SLM were investigated under the influence of thick powder bed, 75 μm layer thickness, and 50 μm layer thickness in various laser powers and scanning speeds. It was found that the layer thickness has a strong influence on microstructural outcome, mainly attributed to its impact on oxygen content of the matrix. Various microstructural features (such as granular, coralline-like, and particulate appearance) were observed depending on the layer thickness, laser power, and scanning speed. This was associated with various material combinations such as pure Al, Al-Fe intermetallics, and Al(-Fe) oxide phases formed after in situ reaction and laser rapid solidification. Uniformly distributed very fine particles could be consolidated in net-shape Al composite parts by using lower layer thickness, higher laser power, and lower scanning speed. The findings contribute to the new development of advanced net-shape manufacture of Al composites by combining SLM and in situ reaction process. PMID:24526879
NASA Astrophysics Data System (ADS)
Chen, Qi; Huang, Shenghai; Ma, Qingkai; Lin, Huiling; Pan, Mengmeng; Liu, Xinting; Lu, Fan; Shen, Meixiao
2017-02-01
The structural characteristics of the outer retinal layers in primary open angle glaucoma (POAG) are still controversial, and these changes, along with those in the inner retinal layers, could have clinical and/or pathophysiological significance. A custom-built ultra-high resolution optical coherence tomography (UHR-OCT) combined with an automated segmentation algorithm can image and measure the eight intra-retinal layers. The purpose of this study is to determine the thickness characteristics of the macular intra-retinal layers, especially the outer layers, in POAG patients. Thirty-four POAG patients (56 eyes) and 33 normal subjects (63 eyes) were enrolled. Thickness profiles of the eight intra-retinal layers along a 6-mm length centred on the fovea at the horizontal and vertical meridians were obtained and the regional thicknesses were compared between two groups. The associations between the thicknesses of each intra-retinal layer and the macular visual field (VF) sensitivity were then analysed. POAG affected not only the inner retinal layers but also the photoreceptor layers and retinal pigment epithelium of the outer retina. However, the VF loss was correlated mainly with the damage of the inner retinal layers. UHR-OCT with automated algorithm is a useful tool in detecting microstructural changes of macula with respect to the progression of glaucoma.
Effect of spacer layer on the magnetization dynamics of permalloy/rare-earth/permalloy trilayers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, Chen, E-mail: ronanluochen@gmail.com; Yin, Yuli; Zhang, Dong
2015-05-07
The permalloy/rare-earth/permalloy trilayers with different types (Gd and Nd) and thicknesses of spacer layer are investigated using frequency dependence of ferromagnetic resonance (FMR) measurements at room temperature, which shows different behaviors with different rare earth spacer layers. By fitting the frequency dependence of the FMR resonance field and linewidth, we find that the in-plane uniaxial anisotropy retains its value for all samples, the perpendicular anisotropy remains almost unchanged for different thickness of Gd layer but the values are tailored by different thicknesses of Nd layer. The Gilbert damping is almost unchanged with different thicknesses of Gd; however, the Gilbert dampingmore » is significantly enhanced from 8.4×10{sup −3} to 20.1×10{sup −3} with 6 nm of Nd and then flatten out when the Nd thickness rises above 6 nm.« less
NASA Technical Reports Server (NTRS)
Goecke, S. A.
1973-01-01
A 0.56-inch thick aft-facing step was located 52.1 feet from the leading edge of the left wing of an XB-70 airplane. A boundary-layer rake at a mirror location on the right wing was used to obtain local flow properties. Reynolds numbers were near 10 to the 8th power, resulting in a relatively thick boundary-layer. The momentum thickness ranged from slightly thinner to slightly thicker than the step height. Surface static pressures forward of the step were obtained for Mach numbers near 0.9, 1.5, 2.0, and 2.4. The data were compared with thin boundary-layer results from flight and wind-tunnel experiments and semiempirical relationships. Significant differences were found between the thick and the thin boundary-layer data.
Effect of layer thickness on device response of silicon heavily supersaturated with sulfur
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hutchinson, David; Department of Physics and Nuclear Engineering, United States Military Academy, West Point NY 10996; Mathews, Jay
2016-05-15
We report on a simple experiment in which the thickness of a hyperdoped silicon layer, supersaturated with sulfur by ion implantation followed by pulsed laser melting and rapid solidification, is systematically varied at constant average sulfur concentration, by varying the implantation energy, dose, and laser fluence. Contacts are deposited and the external quantum efficiency (EQE) is measured for visible wavelengths. We posit that the sulfur layer primarily absorbs light but contributes negligible photocurrent, and we seek to support this by analyzing the EQE data for the different layer thicknesses in two interlocking ways. In the first, we use the measuredmore » concentration depth profiles to obtain the approximate layer thicknesses, and, for each wavelength, fit the EQE vs. layer thickness curve to obtain the absorption coefficient of hyperdoped silicon for that wavelength. Comparison to literature values for the hyperdoped silicon absorption coefficients [S.H. Pan et al. Applied Physics Letters 98, 121913 (2011)] shows good agreement. Next, we essentially run this process in reverse; we fit with Beer’s law the curves of EQE vs. hyperdoped silicon absorption coefficient for those wavelengths that are primarily absorbed in the hyperdoped silicon layer, and find that the layer thicknesses obtained from the fit are in good agreement with the original values obtained from the depth profiles. We conclude that the data support our interpretation of the hyperdoped silicon layer as providing negligible photocurrent at high S concentrations. This work validates the absorption data of Pan et al. [Applied Physics Letters 98, 121913 (2011)], and is consistent with reports of short mobility-lifetime products in hyperdoped layers. It suggests that for optoelectronic devices containing hyperdoped layers, the most important contribution to the above band gap photoresponse may be due to photons absorbed below the hyperdoped layer.« less
NASA Astrophysics Data System (ADS)
Yuan, Wong Wei; Natashah Norizan, Mohd; Salwani Mohamad, Ili; Jamalullail, Nurnaeimah; Hidayah Saad, Nor
2017-11-01
Solar cell is expanding as green renewable alternative to conventional fossil fuel electricity generation, but compared to other land-used electrical generators, it is a comparative beginner. Many applications covered by solar cells starting from low power mobile devices, terrestrial, satellites and many more. To date, the highest efficiency solar cell is given by GaAs based multilayer solar cell. However, this material is very expensive in fabrication and material costs compared to silicon which is cheaper due to the abundance of supply. Thus, this research is devoted to develop multilayer solar cell by combining two different layers of P-I-N structures with silicon carbide and silicon germanium. This research focused on optimising the intrinsic layer thickness, p-doped layer thickness and concentration, n-doped layer thickness and concentration in achieving the highest efficiency. As a result, both single layer a-SiC and a-SiGe showed positive efficiency improvement with the record of 27.19% and 9.07% respectively via parametric optimization. The optimized parameters is then applied on both SiC and SiGe P-I-N layers and resulted the convincing efficiency of 33.80%.
NASA Astrophysics Data System (ADS)
Hernandez Maya, K.; Mitchell, N. C.; Huuse, M.
2017-12-01
Salt topography and thickness variations are important for testing theories of how halokinetic deformation proceeds. The ability to predict thickness variations of salt at small scale is also important for reservoir evaluations, as breach of the salt layer can lead to loss of petroleum fluids and can be difficult to evaluate from seismic reflection data. Relevant to these issues, we here report analysis of data on salt layer topography and thickness from the southern North Sea, where the salt is organized into pillows. These data were derived by the Geological Survey of the Netherlands (TNO) from industry 3D seismic reflection data combined with a dense network of well information. Highs and lows in the topography of the upper salt interface occur spaced over a variety of lengthscales. Power spectral analysis of the interface topography reveals a simple inverse power law relationship between power spectral density and spatial wave number. The relationship suggests that the interface is a self-affine fractal with a fractal dimension of 2.85. A similar analysis of the salt layer thickness also suggests a fractal-like power law. Whereas the layer thickness power law is unsurprising as the underlying basement topography dominates the thickness and it also has a fractal-like power spectrum, the salt topography is not so easily explained as not all the basement faults are overlaid by salt pillows, instead some areas of the dataset salt thinning overlies faults. We consider instead whether a spatially varied loading of the salt layer may have caused this fractal-like geometry. Varied density and thickness of overburdening layers seem unlikely causes, as thicknesses of layers and their reflectivities do not vary sympathetically with the topography of the interface. The composition of the salt layer varies with the relative proportions of halite and denser anhydrite and other minerals. Although limited in scope and representing the mobilized salt layer, the information from the well data could potentially support the loading originating initially from within the salt. Such internal loading needs to be considered in modelling salt deformation for a variety of practical and academic purposes.
NASA Astrophysics Data System (ADS)
Guz, A. N.; Bagno, A. M.
2017-07-01
The dispersion curves are constructed and propagation of quasi-Lamb waves are studied for wide range of frequencies based on the Navier -Stokes three-dimensional linearized equations for a viscous liquid and linear equations of the classical theory of elasticity for an elastic layer. For a thick liquid layer, the effect of the viscosity of the liquid and the thickness of elastic and liquid layers on the phase velocities and attenuation coefficients of quasi-Lamb modes is analyzed. It is shown that in the case of a thick liquid layer for all modes, there are elastic layers of certain thickness with minimal effect of liquid viscosity on the phase velocities and attenuation coefficients of modes. It is also discovered that for some modes, there are both certain thicknesses and certain ranges of thickness where the effect of liquid viscosity on the phase velocities and attenuation coefficients of these modes is considerable. We ascertain that liquid viscosity promotes decrease of the penetration depth of the lowest quasi-Lamb mode into the liquid. The developed approach and the obtained results make it possible to ascertain for wave processes the limits of applicability of the model of ideal compressible fluid. Numerical results in the form of graphs are adduced and analyzed.
NASA Astrophysics Data System (ADS)
Li, Zhi-Yue; Yang, Hao-Zhi; Chen, Sheng-Chi; Lu, Ying-Bo; Xin, Yan-Qing; Yang, Tian-Lin; Sun, Hui
2018-05-01
Nitrogen-doped indium tin zinc oxide (ITZO:N) thin film transistors (TFTs) were deposited on SiO2 (200 nm)/p-Si〈1 0 0〉 substrates by RF magnetron sputtering at room temperature. The structural, chemical compositions, surface morphology, optical and electrical properties as a function of the active layer thickness were investigated. As the active layer thickness increases, Zn content decreases and In content increases gradually. Meanwhile, Sn content is almost unchanged. When the thickness of the active layer is more than 45 nm, the ITZO:N films become crystallized and present a crystal orientation along InN(0 0 2) plan. No matter what the thickness is, ITZO:N films always display a high transmittance above 80% in the visible region. Their optical band gaps fluctuate between 3.4 eV and 3.62 eV. Due to the dominance of low interface trap density and high carrier concentration, ITZO:N TFT shows enhanced electrical properties as the active layer thickness is 35 nm. Its field-effect mobility, on/off radio and sub-threshold swing are 17.53 cm2 V‑1 · s‑1, 106 and 0.36 V/dec, respectively. These results indicate that the suitable thickness of the active layer can enhance the quality of ITZO:N films and decrease the defects density of ITZO:N TFT. Thus, the properties of ITZO:N TFT can be optimized by adjusting the thickness of the active layer.
Hutsler, Jeffrey J; Lee, Dong-Geun; Porter, Kristin K
2005-08-02
The mammalian cerebral cortex is composed of individual layers characterized by the cell types they contain and their afferent and efferent connections. The current study examined the raw, and size-normalized, laminar thicknesses in three cortical regions (somatosensory, motor, and premotor) of fourteen species from three orders of mammals: primates, carnivores, and rodents. The proportional size of the pyramidal cell layers (supra- and infragranular) varied between orders but was similar within orders despite wide variance in absolute cortical thickness. Further, supragranular layer thickness was largest in primates (46 +/- 3 percent), followed by carnivores (36 +/- 3 percent), and then rodents (19 +/- 4 percent), suggesting a distinct difference in the proportion of cortex devoted to corticocortical connectivity across these orders. Although measures of supragranular layer thickness are highly correlated with measures of overall brain size, such associations are not present when independent contrasts are used to control for phylogenetic inertia. Interestingly, neurogenesis time span remains strongly associated with supragranular layer thickness despite size normalization and controlling for phylogenetic inertia. Such layering differences between orders, and similarities amongst species within an order, suggest that supragranular layer expansion may have occurred early in mammalian evolution and may be related to ontogenetic variables such as neurogenesis time span rather than measures of overall size.
Contact method to allow benign failure in ceramic capacitor having self-clearing feature
Myers, John D; Taylor, Ralph S
2012-06-26
A capacitor exhibiting a benign failure mode has a first electrode layer, a first ceramic dielectric layer deposited on a surface of the first electrode, and a second electrode layer disposed on the ceramic dielectric layer, wherein selected areas of the ceramic dielectric layer have additional dielectric material of sufficient thickness to exhibit a higher dielectric breakdown voltage than the remaining majority of the dielectric layer. The added thickness of the dielectric layer in selected areas allows lead connections to be made at the selected areas of greater dielectric thickness while substantially eliminating a risk of dielectric breakdown and failure at the lead connections, whereby the benign failure mode is preserved.
2018-01-01
Objectives To evaluate and compare light-transmittance in dental tissues and dental composite restorations using the incremental double-layer technique with varying layer thickness. Materials and Methods B1-colored natural teeth slabs were compared to dental restoration build-ups with A2D and B1E-colored nanofilled, supra-nanofilled, microfilled, and microhybrid composites. The enamel layer varied from 0.3, 0.5, or 1.2 mm thick, and the dentin layer was varied to provide a standardized 3.7 mm overall sample thickness (n = 10). All increments were light-cured to 16 J/cm2 with a multi-wave LED (Valo, Ultradent). Using a spectrophotometer, the samples were irradiated by an RGB laser beam. A voltmeter recorded the light output signal to calculate the light-transmittance through the specimens. The data were analyzed using 1-way analysis of variance followed by the post hoc Tukey's test (p = 0.05). Results Mean light-transmittance observed at thicker final layers of enamel were significantly lower than those observed at thinner final layers. Within 1.2 mm final enamel resin layer (FERL) thickness, all composites were similar to the dental tissues, with exception of the nanofilled composite. However, within 0.5 mm FERL thickness, only the supra-nanofilled composite showed no difference from the dental tissues. Within 0.3 mm FERL thickness, none of the composites were similar to the dental tissues. Conclusions The supra-nanofilled composite had the most similar light-transmittance pattern when compared to the natural teeth. However, for other composites, thicker FERL have a greater chance to match the light-transmittance of natural dental tissues. PMID:29765902
Wasyluk, Jaromir T.; Jankowska-Lech, Irmina; Terelak-Borys, Barbara; Grabska-Liberek, Iwona
2012-01-01
Summary Background We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. Material/Methods Study subjects had advanced primary open-angle glaucoma, previously treated conservatively, diagnosed and confirmed by additional examinations (visual field, ophthalmoscopy of optic nerve, gonioscopy), A total of 10 patients were enrolled (9 women and 1 man), aged 18–70 years of age. Nineteen eyes with advanced glaucomatous neuropathy were examined. 1) Performing a threshold perimetry Octopus, G2 strategy and ophthalmoscopy of optic nerve to confirm the presence of advanced primary open-angle glaucoma; 2) performing a GDx VCC scanning laser polarimetry of retinal nerve fibre layer; 3) measuring the retinal nerve fibre layer thickness with 3 different optical coherence tomographs. Results The parameters of the retinal nerve fibre layer thickness are highly correlated between the GDx and OCT Stratus and 3D OCT-1000 devices in mean retinal nerve fibre layer thickness, retinal nerve fibre layer thickness in the upper sector, and correlation of NFI (GDx) with mean retinal nerve fibre layer thickness in OCT examinations. Absolute values of the retinal nerve fibre layer thickness (measured in μm) differ significantly between GDx and all OCT devices. Conclusions Examination with OCT devices is a sensitive diagnostic method of glaucoma, with good correlation with the results of GDx scanning laser polarimetry of the patients. PMID:22367131
P-type surface effects for thickness variation of 2um and 4um of n-type layer in GaN LED
NASA Astrophysics Data System (ADS)
Halim, N. S. A. Abdul; Wahid, M. H. A.; Hambali, N. A. M. Ahmad; Rashid, S.; Ramli, M. M.; Shahimin, M. M.
2017-09-01
The internal quantum efficiency of III-Nitrides group, GaN light-emitting diode (LED) has been considerably limited due to the insufficient hole injection and this is caused by the lack of performance p-type doping and low hole mobility. The low hole mobility makes the hole less energetic, thus reduced the performance operation of GaN LED itself. The internal quantum efficiency of GaN-based LED with surface roughness (texture) can be changed by texture size, density, and thickness of GaN film or by the combined effects of surface shape and thickness of GaN film. Besides, due to lack of p-type GaN, attempts to look forward the potential of GaN LED relied on the thickness of n-type layer and surface shape of p-type GaN layer. This work investigates the characteristics of GaN LED with undoped n-GaN layer of different thickness and the surface shape of p-type layer. The LEDs performance is significantly altered by modifying the thickness and shape. Enhancement of n-GaN layer has led to the annihilation of electrical conductivity of the chip. Different surface geometry governs the emission rate extensively. Internal quantum efficiency is also predominantly affected by the geometry of n-GaN layer which subjected to the current spreading. It is recorded that the IQE droop can be minimized by varying the thickness of the active layer without amplifying the forward voltage. Optimum forward voltage (I-V), total emission rate relationship with the injected current and internal quantum efficiency (IQE) for 2,4 µm on four different surfaces of p-type layer are also reported in this paper.
Rocha Maia, Rodrigo; Oliveira, Dayane; D'Antonio, Tracy; Qian, Fang; Skiff, Frederick
2018-05-01
To evaluate and compare light-transmittance in dental tissues and dental composite restorations using the incremental double-layer technique with varying layer thickness. B1-colored natural teeth slabs were compared to dental restoration build-ups with A2D and B1E-colored nanofilled, supra-nanofilled, microfilled, and microhybrid composites. The enamel layer varied from 0.3, 0.5, or 1.2 mm thick, and the dentin layer was varied to provide a standardized 3.7 mm overall sample thickness ( n = 10). All increments were light-cured to 16 J/cm 2 with a multi-wave LED (Valo, Ultradent). Using a spectrophotometer, the samples were irradiated by an RGB laser beam. A voltmeter recorded the light output signal to calculate the light-transmittance through the specimens. The data were analyzed using 1-way analysis of variance followed by the post hoc Tukey's test ( p = 0.05). Mean light-transmittance observed at thicker final layers of enamel were significantly lower than those observed at thinner final layers. Within 1.2 mm final enamel resin layer (FERL) thickness, all composites were similar to the dental tissues, with exception of the nanofilled composite. However, within 0.5 mm FERL thickness, only the supra-nanofilled composite showed no difference from the dental tissues. Within 0.3 mm FERL thickness, none of the composites were similar to the dental tissues. The supra-nanofilled composite had the most similar light-transmittance pattern when compared to the natural teeth. However, for other composites, thicker FERL have a greater chance to match the light-transmittance of natural dental tissues.
Correlation of CsK2Sb photocathode lifetime with antimony thickness
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mamun, M. A.; Hernandez-Garcia, C.; Poelker, M.
CsK2Sb photocathodes with quantum efficiency on the order of 10% at 532 nm, and lifetime greater than 90 days at low voltage, were successfully manufactured via co-deposition of alkali species emanating from an effusion source. Photocathodes were characterized as a function of antimony layer thickness and alkali consumption, inside a vacuum chamber that was initially baked, but frequently vented without re-baking. Photocathode lifetime measured at low voltage is correlated with the antimony layer thickness. Photocathodes manufactured with comparatively thick antimony layers exhibited the best lifetime. We speculate that the antimony layer serves as a reservoir, or sponge, for the alkali.
Controlling the optical parameters of self-assembled silver films with wetting layers and annealing
NASA Astrophysics Data System (ADS)
Ciesielski, Arkadiusz; Skowronski, Lukasz; Trzcinski, Marek; Szoplik, Tomasz
2017-11-01
We investigated the influence of presence of Ni and Ge wetting layers as well as annealing on the permittivity of Ag films with thicknesses of 20, 35 and 65 nm. Most of the research on thin silver films deals with very small (<20 nm) or relatively large (≥50 nm) thicknesses. We studied the transition region (around 30 nm) from charge percolation pathways to fully continuous films and compared the values of optical parameters among silver layers with at least one fixed attribute (thickness, wetting and capping material, post-process annealing). Our study, based on atomic force microscopy, ellipsometric and X-ray photoelectron spectroscopy measurements, shows that utilizing a wetting layer is comparable to increasing the thickness of the silver film. Both operations decrease the roughness-to-thickness ratio, thus decreasing the scattering losses and both narrow the Lorentz-shaped interband transition peak. However, while increasing silver thickness increases absorption on the free carriers, the use of wetting layers influences the self-assembled internal structure of silver films in such a way, that the free carrier absorption decreases. Wetting layers also introduce additional contributions from effects like segregation or diffusion, which evolve in time and due to annealing.
NASA Astrophysics Data System (ADS)
Nakajima, Ryo; Azuma, Atsushi; Yoshida, Hayato; Shimizu, Tomohiro; Ito, Takeshi; Shingubara, Shoso
2018-06-01
Resistive random access memory (ReRAM) devices with a HfO2 dielectric layer have been studied extensively owing to the good reproducibility of their SET/RESET switching properties. Furthermore, it was reported that a thin Hf layer next to a HfO2 layer stabilized switching properties because of the oxygen scavenging effect. In this work, we studied the Hf thickness dependence of the resistance switching characteristics of a Ti/Hf/HfO2/Au ReRAM device. It is found that the optimum Hf thickness is approximately 10 nm to obtain good reproducibility of SET/RESET voltages with a small RESET current. However, when the Hf thickness was very small (∼2 nm), the device failed after the first RESET process owing to the very large RESET current. In the case of a very thick Hf layer (∼20 nm), RESET did not occur owing to the formation of a leaky dielectric layer. We observed the occurrence of multiple resistance states in the RESET process of the device with a Hf thickness of 10 nm by increasing the RESET voltage stepwise.
Role of adrenals in the mobilization of carbohydrate and fat resources after overstimulation of rats
NASA Technical Reports Server (NTRS)
Khechninashvili, G. G.
1980-01-01
The role of the cortical and cerebral layers of the adrenal glands in mobilizing carbohydrate and fatty resources in response to the effect of an extreme stimulant was investigated. It is shown that following adrenodemedullation and adrenalectomy, the leading role is played by the secretion of the adrenal medullary layer, whereas the role of suprarenals in the mobilization of fats is only slightly pronounced.
USDA-ARS?s Scientific Manuscript database
The effects of 2 supplemental levels of dietary poultry fat (PF) and the combination of PF, phytase (PHY) and 25-hydroxycholecalciferol [25(OH)D] on the blood characteristics of commercial layers inoculated with F-strain Mycoplasma gallisepticum (FMG) were investigated in 2 trials. Sham and FMG ino...
USDA-ARS?s Scientific Manuscript database
The effects of 2 supplemental levels of dietary poultry fat (PF) and the combination of PF, phytase (PHY) and 25-hydroxycholecalciferol (D3) on the egg characteristics of commercial layers inoculated with F-strain Mycoplasma gallisepticum (FMG) were investigated in 2 trials. Sham and FMG inoculatio...
Retinal nerve fiber layer changes after LASIK evaluated with optical coherence tomography.
Dementyev, Dmitriy D; Kourenkov, Vyacheslav V; Rodin, Alexander S; Fadeykina, Tatyana L; Diaz Martines, Tatyana E
2005-01-01
To determine whether the increase in intraocular pressure (IOP) during LASIK suction can induce a decrease in retinal nerve fiber layer thickness assessed by optical coherence tomography (OCT). Nineteen patients (38 eyes) were enrolled in the study. Intraocular pressure was normal at all pre- and postoperative examinations. Retinal nerve fiber layer thickness was measured using OCT-3 Stratus prior to and 1 week and 3 months after LASIK. Laser in situ keratomileusis was performed using the Bausch & Lomb Hansatome microkeratome and the NIDEK EC-5000 excimer laser. Optical coherence tomography mean retinal nerve fiber layer thickness values before and after LASIK were compared using the Student paired t test. Mean patient age was 27.8 years (range: 18 to 33 years). Mean preoperative spherical equivalent refractive error was -4.9 diopters (D) (range: -2.0 to -8.5 D). Mean time of microkeratome suction was 30 seconds (range: 20 to 50 seconds). Preoperatively, the mean retinal nerve fiber layer thickness obtained by OCT was 104.2+/-9.0 microm; at 1 week postoperatively the mean thickness was 101.9+/-6.9 microm, and 106.7+/-6.1 microm at 3 months postoperatively. Mean retinal nerve fiber layer thicknesses obtained by OCT were not significantly different between preoperative and 1 week and 3 months after LASIK (P > or = .05). Laser in situ keratomileusis performed on young myopic patients does not have a significant effect on retinal nerve fiber layer thickness determined by OCT. Further studies are required to reveal the risk of possible optic nerve or retinal nerve fiber layer damage by elevated IOP during LASIK.
Yamakawa, Kazuhiro; Aoki, Takahiro; Matsui, Motozumi; Yamada, Kazutaka; Ishii, Mitsuo
2012-05-01
To establish a method to predict postpartum diseases using prepartum back fat thickness (BFT), the peripartum BFTs of 54 healthy multiparous cows before calving, which were diagnosed with postpartum displacement of the abomasum (DA), clinical ketosis or subclinical ketosis were compared with those of healthy cows from 8 weeks before the expected calving date to 8 weeks after calving. The peripartum BFTs of the cows with DA or clinical ketosis were significantly higher than those of healthy cows. The peripartum BFTs of the cows with subclinical ketosis were not significantly higher than those of the healthy cows.
Lin, Heng-Hsu; Lee, Jen-Kuang; Yang, Chung-Yi; Lien, Yu-Chung; Huang, Jenq-Wen; Wu, Cho-Kai
2013-08-30
Symptoms of heart failure with preserved left ventricular systolic function are common among patients undergoing peritoneal dialysis (PD). Epicardial fat (EpF) is an ectopic fat depot with possible paracrine or mechanical effects on myocardial function. The aim of our current study is to assess the association between EpF and Left ventricular diastolic dysfunction (LVDD) in patients undergoing PD and to clarify the relationships among EpF, inflammation, and LVDD in this population. This was a cross-sectional study of 149 patients with preserved left ventricular systolic function who were undergoing PD. LVDD was diagnosed (according to the European Society of Cardiology guidelines) and EpF thickness measured by echocardiography. The patients without LVDD were used as controls. The serum inflammatory biomarker high-sensitivity C-reactive protein (hsCRP) was measured. The location and amount of adipose tissue were assessed by computed tomography (CT) at the level of the fourth lumbar vertebra. Subjects with LVDD had higher levels of hsCRP, more visceral and peritoneal fat, and thicker EpF (all p < 0.001) than controls. Visceral adipose tissue, hsCRP, and EpF all correlated significantly (p < 0.05) with LVDD. Multivariate regression analysis rendered the relationship between visceral adipose tissue and LVDD insignificant, whereas EpF was the most powerful determinant of LVDD (odds ratio = 2.41, 95% confidence interval = 1.43-4.08, p < 0.01). EpF thickness also correlated significantly with the ratio of transmitral Doppler early filling velocity to tissue Doppler early diastolic mitral annular velocity (E/e'; r = 0.27, p < 0.01). EpF thickness is significantly independently associated with LVDD in patients undergoing PD and may be involved in its pathogenesis.
2013-01-01
Background Symptoms of heart failure with preserved left ventricular systolic function are common among patients undergoing peritoneal dialysis (PD). Epicardial fat (EpF) is an ectopic fat depot with possible paracrine or mechanical effects on myocardial function. The aim of our current study is to assess the association between EpF and Left ventricular diastolic dysfunction (LVDD) in patients undergoing PD and to clarify the relationships among EpF, inflammation, and LVDD in this population. Methods This was a cross-sectional study of 149 patients with preserved left ventricular systolic function who were undergoing PD. LVDD was diagnosed (according to the European Society of Cardiology guidelines) and EpF thickness measured by echocardiography. The patients without LVDD were used as controls. The serum inflammatory biomarker high-sensitivity C-reactive protein (hsCRP) was measured. The location and amount of adipose tissue were assessed by computed tomography (CT) at the level of the fourth lumbar vertebra. Results Subjects with LVDD had higher levels of hsCRP, more visceral and peritoneal fat, and thicker EpF (all p < 0.001) than controls. Visceral adipose tissue, hsCRP, and EpF all correlated significantly (p < 0.05) with LVDD. Multivariate regression analysis rendered the relationship between visceral adipose tissue and LVDD insignificant, whereas EpF was the most powerful determinant of LVDD (odds ratio = 2.41, 95% confidence interval = 1.43–4.08, p < 0.01). EpF thickness also correlated significantly with the ratio of transmitral Doppler early filling velocity to tissue Doppler early diastolic mitral annular velocity (E/e’; r = 0.27, p < 0.01). Conclusion EpF thickness is significantly independently associated with LVDD in patients undergoing PD and may be involved in its pathogenesis. PMID:24001037
Venlet, Jeroen; Piers, Sebastiaan R D; Kapel, Gijsbert F L; de Riva, Marta; Pauli, Philippe F G; van der Geest, Rob J; Zeppenfeld, Katja
2017-08-01
Low endocardial unipolar voltage (UV) at sites with normal bipolar voltage (BV) may indicate epicardial scar. Currently applied UV cutoff values are based on studies that lacked epicardial fat information. This study aimed to define endocardial UV cutoff values using computed tomography-derived fat information and to analyze their clinical value for right ventricular substrate delineation. Thirty-three patients (50±14 years; 79% men) underwent combined endocardial-epicardial right ventricular electroanatomical mapping and ablation of right ventricular scar-related ventricular tachycardia with computed tomographic image integration, including computed tomography-derived fat thickness. Of 6889 endocardial-epicardial mapping point pairs, 547 (8%) pairs with distance <10 mm and fat thickness <1.0 mm were analyzed for voltage and abnormal (fragmented/late potential) electrogram characteristics. At sites with endocardial BV >1.50 mV, the optimal endocardial UV cutoff for identification of epicardial BV <1.50 mV was 3.9 mV (area under the curve, 0.75; sensitivity, 60%; specificity, 79%) and cutoff for identification of abnormal epicardial electrogram was 3.7 mV (area under the curve, 0.88; sensitivity, 100%; specificity, 67%). The majority of abnormal electrograms (130 of 151) were associated with transmural scar. Eighty-six percent of abnormal epicardial electrograms had corresponding endocardial sites with BV <1.50 mV, and the remaining could be identified by corresponding low endocardial UV <3.7 mV. For identification of epicardial right ventricular scar, an endocardial UV cutoff value of 3.9 mV is more accurate than previously reported cutoff values. Although the majority of epicardial abnormal electrograms are associated with transmural scar with low endocardial BV, the additional use of endocardial UV at normal BV sites improves the diagnostic accuracy resulting in identification of all epicardial abnormal electrograms at sites with <1.0 mm fat. © 2017 American Heart Association, Inc.
Li, Hongkai; Zhao, Qian; Lu, Xinchun; Luo, Jianbin
2017-11-01
In the copper (Cu) chemical mechanical planarization (CMP) process, accurate determination of a process reaching the end point is of great importance. Based on the eddy current technology, the in situ thickness measurement of the Cu layer is feasible. Previous research studies focus on the application of the eddy current method to the metal layer thickness measurement or endpoint detection. In this paper, an in situ measurement system, which is independently developed by using the eddy current method, is applied to the actual Cu CMP process. A series of experiments are done for further analyzing the dynamic response characteristic of the output signal within different thickness variation ranges. In this study, the voltage difference of the output signal is used to represent the thickness of the Cu layer, and we can extract the voltage difference variations from the output signal fast by using the proposed data processing algorithm. The results show that the voltage difference decreases as thickness decreases in the conventional measurement range and the sensitivity increases at the same time. However, it is also found that there exists a thickness threshold, and the correlation is negative, when the thickness is more than the threshold. Furthermore, it is possible that the in situ measurement system can be used within a larger Cu layer thickness variation range by creating two calibration tables.
Tailoring Curie temperature and magnetic anisotropy in ultrathin Pt/Co/Pt films
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parakkat, Vineeth Mohanan; Ganesh, K. R.; Anil Kumar, P. S., E-mail: anil@physics.iisc.ernet.in
The dependence of perpendicular magnetization and Curie temperature (T{sub c}) of Pt/Co/Pt thin films on the thicknesses of Pt seed (Pt{sub s}) and presence of Ta buffer layer has been investigated in this work. Pt and Co thicknesses were varied between 2 to 8 nm and 0.35 to 1.31 nm (across the spin reorientation transition thickness) respectively and the T{sub c} was measured using SQUID magnetometer. We have observed a systematic dependence of T{sub c} on the thickness of Pt{sub s}. For 8 nm thickness of Pt{sub s} the Co layer of 0.35 nm showed ferromagnetism with perpendicular anisotropy atmore » room temperature. As the thickness of the Pt{sub s} was decreased to 2 nm, the T{sub c} went down below 250 K. XRD data indicated polycrystalline growth of Pt{sub s} on SiO{sub 2}. On the contrary Ta buffer layer promoted the growth of Pt(111). As a consequence Ta(5 nm)/Pt(3 nm)/Co(0.35 nm)/Pt(2 nm) had much higher T{sub c} (above 300 K) with perpendicular anisotropy when compared to the same stack without the Ta layer. Thus we could tune the ferromagnetic T{sub c} and anisotropy by varying the Pt{sub s} thickness and also by introducing Ta buffer layer. We attribute these observations to the micro-structural evolution of Pt{sub s} layer which hosts the Co layer.« less
Röhe, Ilen; Hüttner, Friedrich Joseph; Plendl, Johanna; Drewes, Barbara; Zentek, Jürgen
2018-02-05
The histological characterization of the intestinal mucus layer is important for many scientific experiments investigating the interaction between intestinal microbiota, mucosal immune response and intestinal mucus production. The aim of this study was to examine and compare different fixation protocols for displaying and quantifying the intestinal mucus layer in piglets and to test which histomorphological parameters may correlate with the determined mucus layer thickness. Jejunal and colonal tissue samples of weaned piglets (n=10) were either frozen in liquid nitrogen or chemically fixed using methacarn solution. The frozen tissue samples were cryosectioned and subsequently postfixed using three different postfixatives: paraformaldehyde vapor, neutrally buffered formalin solution and ethanol solution. After dehydration, methacarn fixed tissues were embedded in paraffin wax. Both sections of cryopreserved and methacarn fixed tissue samples were stained with Alcian blue (AB)-PAS followed by the microscopically determination of the mucus layer thickness. Different pH values of the Alcian Blue staining solution and two mucus layer thickness measuring methods were compared. In addition, various histomorphological parameters of methacarn fixed tissue samples were evaluated including the number of goblet cells and the mucin staining area. Cryopreservation in combination with chemical postfixation led to mucus preservation in the colon of piglets allowing mucus thickness measurements. Mucus could be only partly preserved in cryosections of the jejunum impeding any quantitative description of the mucus layer thickness. The application of different postfixations, varying pH values of the AB solution and different mucus layer measuring methods led to comparable results regarding the mucus layer thickness. Methacarn fixation proved to be unsuitable for mucus depiction as only mucus patches were found in the jejunum or a detachment of the mucus layer from the epithelium was observed in the colon. Correlation analyses revealed that the proportion of the mucin staining area per crypt area (relative mucin staining) measured in methacarn fixed tissue samples corresponded to the colonal mucus layer thickness determined in cryopreserved tissue samples. In conclusion, the results showed that cryopreservation using liquid nitrogen followed by chemical postfixation and AB-PAS staining led to a reliable mucus preservation allowing a mucus thickness determination in the colon of pigs. Moreover, the detected relative mucin staining area may serve as a suitable histomorphological parameter for the assessment of the intestinal mucus layer thickness. The findings obtained in this study can be used for the implementation of an improved standard for the histological description of the mucus layer in the colon of pigs.
Chen, Kun-Neng; Yang, Cheng-Fu; Wu, Chia-Ching; Chen, Yu-Hsin
2017-02-24
We investigated the structural, optical, and electrical properties of amorphous IGZO/silver/amorphous IGZO (α-IGZO/Ag/α-IGZO) triple-layer structures that were deposited at room temperature on Eagle XG glass and flexible polyethylene terephthalate substrates through the sputtering method. Thin Ag layers with different thicknesses were inserted between two IGZO layers to form a triple-layer structure. Ag was used because of its lower absorption and resistivity. Field emission scanning electron microscopy measurements of the triple-layer structures revealed that the thicknesses of the Ag layers ranged from 13 to 41 nm. The thickness of the Ag layer had a large effect on the electrical and optical properties of the electrodes. The optimum thickness of the Ag metal thin film could be evaluated according to the optical transmittance, electrical conductivity, and figure of merit of the electrode. This study demonstrates that the α-IGZO/Ag/α-IGZO triple-layer transparent electrode can be fabricated with low sheet resistance (4.2 Ω/□) and high optical transmittance (88.1%) at room temperature without postannealing processing on the deposited thin films.
Bhaduri, Basanta; Shelton, Ryan L; Nolan, Ryan M; Hendren, Lucas; Almasov, Alexandra; Labriola, Leanne T; Boppart, Stephen A
2017-11-01
Influence of diabetes mellitus (DM) and diabetic retinopathy (DR) on parafoveal retinal thicknesses and their ratios was evaluated. Six retinal layer boundaries were segmented from spectral-domain optical coherence tomography images using open-source software. Five study groups: (1) healthy control (HC) subjects, and subjects with (2) controlled DM, (3) uncontrolled DM, (4) controlled DR and (5) uncontrolled DR, were identified. The one-way analyses of variance (ANOVA) between adjacent study groups (i. e. 1 with 2, 2 with 3, etc) indicated differences in retinal thicknesses and ratios. Overall retinal thickness, ganglion cell layer (GCL) thickness, inner plexiform layer (IPL) thickness, and their combination (GCL+ IPL), appeared to be significantly less in the uncontrolled DM group when compared to controlled DM and controlled DR groups. Although the combination of nerve fiber layer (NFL) and GCL, and IPL thicknesses were not different, their ratio, (NFL+GCL)/IPL, was found to be significantly higher in the controlled DM group compared to the HC group. Comparisons of the controlled DR group with the controlled DM group, and with the uncontrolled DR group, do not show any differences in the layer thicknesses, though several significant ratios were obtained. Ratiometric analysis may provide more sensitive parameters for detecting changes in DR. Picture: A representative segmented OCT image of the human retina is shown. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
On the origins of hardness of Cu–TiN nanolayered composites
Pathak, S.; Li, N.; Maeder, X.; ...
2015-07-18
We investigated the mechanical response of physical vapor deposited Cu–TiN nanolayered composites of varying layer thicknesses from 5 nm to 200 nm. Both the Cu and TiN layers were found to consist of single phase nanometer sized grains. The grain sizes in the Cu and TiN layers, measured using transmission electron microscopy and X-ray diffraction, were found to be comparable to or smaller than their respective layer thicknesses. Indentation hardness testing revealed that the hardness of such nanolayered composites exhibits a weak dependence on the layer thickness but is more correlated to their grain size.
Method for depositing layers of high quality semiconductor material
Guha, Subhendu; Yang, Chi C.
2001-08-14
Plasma deposition of substantially amorphous semiconductor materials is carried out under a set of deposition parameters which are selected so that the process operates near the amorphous/microcrystalline threshold. This threshold varies as a function of the thickness of the depositing semiconductor layer; and, deposition parameters, such as diluent gas concentrations, must be adjusted as a function of layer thickness. Also, this threshold varies as a function of the composition of the depositing layer, and in those instances where the layer composition is profiled throughout its thickness, deposition parameters must be adjusted accordingly so as to maintain the amorphous/microcrystalline threshold.
The effect of the MgO buffer layer thickness on magnetic anisotropy in MgO/Fe/Cr/MgO buffer/MgO(001)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kozioł-Rachwał, Anna, E-mail: a.koziolrachwal@aist.go.jp; AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, al. Mickiewicza 30, 30-059 Kraków; Nozaki, Takayuki
2016-08-28
The relationship between the magnetic properties and MgO buffer layer thickness d was studied in epitaxial MgO/Fe(t)/Cr/MgO(d) layers grown on MgO(001) substrate in which the Fe thickness t ranged from 0.4 nm to 1.1 nm. For 0.4 nm ≤ t ≤ 0.7 nm, a non-monotonic coercivity dependence on the MgO buffer thickness was shown by perpendicular magneto-optic Kerr effect magnetometry. For thicker Fe films, an increase in the buffer layer thickness resulted in a spin reorientation transition from perpendicular to the in-plane magnetization direction. Possible origins of these unusual behaviors were discussed in terms of the suppression of carbon contamination at the Fe surface and changes inmore » the magnetoelastic anisotropy in the system. These results illustrate a method to control magnetic anisotropy in MgO/Fe/Cr/MgO(d) via an appropriate choice of MgO buffer layer thickness d.« less
Mallik, Arun Kumar; Farrell, Gerald; Wu, Qiang; Semenova, Yuliya
2017-05-10
In this paper, we investigate both theoretically and experimentally the influence of the agarose hydrogel layer thickness on the sensitivity of a proposed relative humidity (RH) sensor based on a silica microsphere resonator coated with agarose hydrogel. The operating principle of the sensor relies on excitation of whispering gallery modes (WGMs) in the coated silica microsphere using the evanescent field of a tapered fiber. A change in the ambient relative humidity is detected by measuring the wavelength shift of the WGMs in the transmission spectrum of the tapered fiber. Using perturbation theory, we analyze the influence of the agarose coating thickness on the sensitivity of the proposed sensor and compare the results of this analysis with experimental findings for different coating layer thicknesses. We demonstrate that an increase in the coating layer thickness initially leads to an increase in the sensitivity to RH and reaches saturation at higher values of the agarose layer thickness. The results of the study are useful for the design and optimization of microsphere sensor parameters to meet a performance specification.
Li, Xin; Jordan, Matthew B; Ayari, Taha; Sundaram, Suresh; El Gmili, Youssef; Alam, Saiful; Alam, Muhbub; Patriarche, Gilles; Voss, Paul L; Paul Salvestrini, Jean; Ougazzaden, Abdallah
2017-04-11
Practical boron nitride (BN) detector applications will require uniform materials over large surface area and thick BN layers. To report important progress toward these technological requirements, 1~2.5 µm-thick BN layers were grown on 2-inch sapphire substrates by metal-organic vapor phase epitaxy (MOVPE). The structural and optical properties were carefully characterized and discussed. The thick layers exhibited strong band-edge absorption near 215 nm. A highly oriented two-dimensional h-BN structure was formed at the film/sapphire interface, which permitted an effective exfoliation of the thick BN film onto other adhesive supports. And this structure resulted in a metal-semiconductor-metal (MSM) device prototype fabricated on BN membrane delaminating from the substrate. MSM photodiode prototype showed low dark current of 2 nA under 100 V, and 100 ± 20% photoconductivity yield for deep UV light illumination. These wafer-scale MOVPE-grown thick BN layers present great potential for the development of deep UV photodetection applications, and even for flexible (opto-) electronics in the future.
de la Horra, Ana E; Barrera, Gabriela N; Steffolani, Eugenia M; Ribotta, Pablo D; León, Alberto E
2017-08-01
The aim of this study was to establish relationships between structural fat properties and sensory, physical and textural attributes of yeast-leavened laminated salty products. Refined bovine fat (MG1) and shortening (MG2), with a solid fat content (SFC) higher than 20% at temperature range of 15-35 °C were more viscous and less sensitive to temperature changes. The micrographs of dough|fat|dough sections corresponding to samples with MG1 and MG2 revealed a lower penetration of the fat sheet in the dough section due to the more entangled fat structures that did not allow a great flow throughout the dough layer. Consequently, the structure of laminated dough pieces made the systems highly resistant to deformation. The laminated dough pieces elaborated with these fats showed the highest increments in their height and maintained symmetry. Products with fat with least SFC and higher destructuration rate produced smoother laminated structures due to the presence of pores. While products with MG1 and MG2 showed tortuous images and complex structures, associated to layers and extended pores. MG1 and MG2 products were preferred (flavor and appearance) over those with MG3. The highest ranking samples in the acceptability analysis were symmetric, presented very flaky crusts and had a high level of lamination.
Kang, Dong Hyuk; Chung, Jae Hoon; Kim, Yong Jin; Lee, Haeng Nam; Cho, Seung Hoon; Chang, Taek Hee; Lee, Seung Wook
2012-08-01
This study aimed to investigate the efficacy and safety of autologous fat injection (AFI) for penile girth enhancement (PGE) in patients with thin penises. This study investigated 52 patients with a small penile circumference who underwent AFI for PGE and were followed up for more than 6 months. The patients whose proximal one third (G1) and distal one third of their penis (G2) had a mean thickness of 7.4 cm or less were selected as subjects. After fat suction using a liposuction device, fat was evenly injected into the superficial, middle, and deep layers of the Colles' fascia. Patient age and operative time were analyzed. The G1, G2, flaccid (L1), stretched length (L2), and five-item version of the International Index of Erectile Function-5 (IIEF-5) before and 6 months after the surgery were compared. Postoperative complications were surveyed. The patient mean age was 42.15 years (range, 22-56) years, and the operative time was 44.44 min (range, 37-49 min). The injected fat volume was 38.54 ml (range, 25-49 ml). Preoperatively, G1 was 7.01±0.39 cm, and G2 was 7.06±0.37 cm. Postoperatively, G1 was 9.29±0.82 cm (P<0.001), and G2 was 9.34±0.86 (P<0.001) cm 6 months after the surgery. The difference between L1 and L2 before and after the surgery was not significant. The IIEF-5 was 19.10±3.22 before the surgery and 19.90±3.05 after the surgery (P=0.001). The only complication was nodular fat observed in one case (1.92%). The use of AFI for PGE in men with thin penises was effective and safe without major complications. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at www.springer.com/00266.
Chen, Guangxin; Gao, Zhenhua; Chu, Wenhui; Cao, Zan; Li, Chunyi
2018-01-01
Objective This experiment was conducted to investigate the effects of chromium picolinate (CrP) on fat deposition, genetic expression and enzymatic activity of lipid metabolism-related enzymes. Methods Two hundred forty one-day-old Ross broilers were randomly divided into 5 groups with 4 replicates per group and 12 Ross broiler chicks per replicate. The normal control group was fed a basal diet, and the other groups fed the same basal diet supplemented with 0.1, 0.2, 0.4, and 0.8 mg/kg CrP respectively. The experiment lasted for 21 days. Results Added CrP in the basal diet decreased the abdominal fat, had no effects on subcutaneous fat thickness and inter-muscular fat width; 0.2 mg/kg CrP significantly decreased the fatty acid synthase (FAS) enzymatic (p<0.05); acetyl-CoA carboxylase (ACC) enzymatic activity decreased in all CrP groups (p<0.05); hormone-sensitive lipase (HSL) enzymatic activity also decreased, but the change was not significant (p>0.05); 0.4 mg/kg CrP group significantly decreased the lipoprotein lipase (LPL) enzymatic activity. FAS mRNA expression increased in all experimental groups, and the LPL mRNA expression significantly increased in all experimental groups (p<0.05), but not 0.2 mg/kg CrP group. Conclusion The results indicated that adding CrP in basal diet decreased the abdominal fat percentage, had no effects on subcutaneous fat thickness and inter-muscular fat width, decreased the enzymatic activity of FAS, ACC, LPL and HSL and increased the genetic expression levels of FAS and LPL. PMID:28830127
Chen, Guangxin; Gao, Zhenhua; Chu, Wenhui; Cao, Zan; Li, Chunyi; Zhao, Haiping
2018-04-01
This experiment was conducted to investigate the effects of chromium picolinate (CrP) on fat deposition, genetic expression and enzymatic activity of lipid metabolism-related enzymes. Two hundred forty one-day-old Ross broilers were randomly divided into 5 groups with 4 replicates per group and 12 Ross broiler chicks per replicate. The normal control group was fed a basal diet, and the other groups fed the same basal diet supplemented with 0.1, 0.2, 0.4, and 0.8 mg/kg CrP respectively. The experiment lasted for 21 days. Added CrP in the basal diet decreased the abdominal fat, had no effects on subcutaneous fat thickness and inter-muscular fat width; 0.2 mg/kg CrP significantly decreased the fatty acid synthase (FAS) enzymatic (p<0.05); acetyl-CoA carboxylase (ACC) enzymatic activity decreased in all CrP groups (p<0.05); hormone-sensitive lipase (HSL) enzymatic activity also decreased, but the change was not significant (p>0.05); 0.4 mg/kg CrP group significantly decreased the lipoprotein lipase (LPL) enzymatic activity. FAS mRNA expression increased in all experimental groups, and the LPL mRNA expression significantly increased in all experimental groups (p<0.05), but not 0.2 mg/kg CrP group. The results indicated that adding CrP in basal diet decreased the abdominal fat percentage, had no effects on subcutaneous fat thickness and inter-muscular fat width, decreased the enzymatic activity of FAS, ACC, LPL and HSL and increased the genetic expression levels of FAS and LPL.
Gulmez Sevim, Duygu; Unlu, Metin; Gultekin, Murat; Karaca, Cagatay
2018-02-12
There have been ongoing clinical trials of therapeutic agents in Huntington's disease (HD) which requires development of reliable biomarkers of disease progression. There have been studies in the literature with conflicting results on the involvement of retina in HD, and up to date there is not a study evaluating the single retinal layers in HD. We aimed to evaluate the specific retinal changes in HD and their usability as potential disease progression markers. This cross-sectional study used spectral-domain optical coherence tomography with automatic segmentation to measure peripapillary retinal nerve fiber layer (pRNFL) thickness and the thickness and volume of retinal layers in foveal scans of 15 patients with HD and 15 age- and sex-matched controls. Genetic testing results, disease duration, HD disease burden scores and Unified HD Rating Scales motor scores were acquired for the patients. Temporal pRNFL, macular RNFL (mRNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer and outer plexiform layer thicknesses and IPL, retinal pigment epithelium and outer macular volume were found lower in HD compared to controls, while outer nuclear layer and outer retinal layer thickness were increased (p < 0.05). We found significant correlations between inner retinal layer thicknesses, most significantly with mRNFL and GCL and disease progression markers. The outcomes of this study points out that retinal layers, most significantly mRNFL and GCL, are strongly correlated with the disease progression in HD and could serve as useful biomarkers for disease progression.
Cloud Thickness from Offbeam Returns (THOR) Validation Campaign on NASA's P3B Over the ARM/SGP
NASA Technical Reports Server (NTRS)
Cahalan, R. F.; Kolasinski, J.; McGill, M.; Lau, William K. M. (Technical Monitor)
2002-01-01
Physical thickness of a cloud layer, sometimes multiple cloud layers, is a crucial controller of solar heating of the Earth- atmosphere system, which drives the convective processes that produce storm systems. Yet clouds of average optical thickness are opaque to conventional lidar, so their thickness is well estimated only by combining a lidar above and another below cloud, or a radar and lidar on the same side, dual facilities not widely available. Here we report initial observations of a new airborne multiple field of view lidar, capable of determining physical thickness of cloud layers from time signatures of off-beam returns from a I kHz micropulse lidar at 540 rim. For a single layer, the time delay of light returning from the outer diffuse halo of light surrounding the beam entry point, relative to the time delay at beam center, determines the cloud physical thickness. The delay combined with the pulse stretch gives the optical thickness. This halo method requires cloud optical thickness exceeding 2, and improves with cloud thickness, thus complimenting conventional lidar, which cannot penetrate thick clouds. Results are presented from March 25, 2002, when THOR flew a butterfly pattern over the ARM site at 8.3 km, above a thin ice cloud at 5 km, and a thick boundary-layer stratus deck with top at 1.3 km, as shown by THOR channel 1, and a base at about 0.3 km as shown by the ground-based MPL. Additional information is included in the original extended abstract.
Sousa, Dannylo Oliveira; Mesquita, Bruno de Sousa; Pires, Alexandre Vaz; Santana, Miguel Henrique de Almeida; Silva, Luis Felipe Prada
2017-10-01
The objective was to evaluate effects of neutral detergent fibre (NDF) digestibility and level of fresh sugarcane on intake, body fatness, carcass characteristics, and rumen kinetics and fermentation of beef cattle. Forty-eight Nellore young bulls were used in a complete randomized block design with a 2 × 2 factorial arrangement of treatments. Eight rumen-cannulated Nellore steers were used in a replicated 4 × 4 Latin square design. Two sugarcane genotypes divergent for stalk NDF digestibility (NDFD) were used. Experimental diets were formulated with 20 or 40% of sugarcane on a dry matter (DM) basis. High-NDFD genotype associated with the lower level of roughage in the diet promoted greater DM intake, resulting in greater body gain. Sugarcane with high-NDFD increased final body weight, hot carcass weight, and back-fat thickness. Animals receiving the genotype with high NDFD had greater rump-fat thickness only with 40% sugarcane in the diet. Animals receiving the low-NDFD genotype at 20% of the diet had lower NDF passage rate. Rumen pH was greater for diets with greater NDF content. There was greater proportion of butyrate in the rumen of animals receiving diets with greater NDF content. In conclusion, high-NDFD sugarcane increased final body and carcass weight, HCW, and fat thickness. When associated with lower inclusion of roughage in the diet, it can also increase DM intake and body weight gain of beef cattle.
NASA Astrophysics Data System (ADS)
Mase, Suguru; Hamada, Takeaki; Freedsman, Joseph J.; Egawa, Takashi
2018-06-01
We have demonstrated a vertical GaN-on-Si p-n diode with breakdown voltage (BV) as high as 839 V by using a low Si-doped strained layer superlattice (SLS). The p-n vertical diode fabricated by using the n‑-SLS layer as a part of the drift layer showed a remarkable enhancement in BV, when compared with the conventional n‑-GaN drift layer of similar thickness. The vertical GaN-on-Si p-n diodes with 2.3 μm-thick n‑-GaN drift layer and 3.0 μm-thick n‑-SLS layer exhibited a differential on-resistance of 4.0 Ω · cm2 and a BV of 839 V.
NASA Astrophysics Data System (ADS)
Bush, A. A.; Shkuratov, V. Ya.; Chernykh, I. A.; Fetisov, Y. K.
2010-03-01
Layered thick-film composites containing one lead zirconate titanate (PZT) layer, one nickel zinc ferrite (NZF) layer, two PZT-NZF layers, or three PZT-NZF-PZT layers each 40-50 μm thick are prepared. The layers are applied by screen printing on a ceramic aluminum oxide substrate with a preformed contact (conducting) layer. The dielectric properties of the composites are studied in the temperature interval 80-900 K and the frequency interval 25 Hz-1 MHz. Polarized samples exhibit piezoelectric, pyroelectric, and magnetoelectric effects. In tangentially magnetized two- and three-layer composites, the magnetoelectric conversion factor equals 57 kV/(m T) at low frequencies and reaches 2000 kV/(m T) at the mechanical resonance frequency.
A Study of the Physical Processes of an Advection Fog BoundaryLayer
NASA Astrophysics Data System (ADS)
Liu, D.; Yan, W.; Kang, Z.; Dai, Z.; Liu, D.; Liu, M.; Cao, L.; Chen, H.
2016-12-01
Using the fog boundary layer observation collected by a moored balloon between December 1 and 2, 2009, the processes of advection fog formation and dissipation under cold and warm double-advection conditions was studied. the conclusions are as follows: 1. The advection fog process was generated by the interaction between the near-surface northeast cold advection and the upper layer's southeast warm, humid advection. The ground fog formed in an advection cooling process, and the thick fog disappeared in two hours when the wind shifted from the northeast to the northwest. The top of the fog layer remained over 600 m for most of the time. 2. This advection fog featured a double-inversion structure. The interaction between the southeast warm, humid advection of the upper layer and the descending current generated the upper inversion layer. The northeast cold advection near the ground and the warm, humid advection in the high-altitude layer formed the lower layer clouds and lower inversion layer. The upper inversion layer was composed of southeast warm, humid advection and a descending current with increasing temperature. The double inversion provided good thermal conditions for maintaining the thick fog layer. 3. The southeast wind of the upper layer not only created the upper inversion layer but also brought vapour-rich air to the fog region. The steady southeast vapour transportation by the southeast wind was the main condition that maintained the fog thickness, homogeneous density, and long duration. The low-altitude low-level jet beneath the lower inversion layer helped maintain the thickness and uniform density of the fog layer by enhancing the exchange of heat, momentum and vapour within the lower inversion layer. 4. There were three transportation mechanisms associated with this advection fog: 1) The surface layer vapour was delivered to the lower fog layer. 2) The low-altitude southeast low-level jet transported the vapour to the upper layer. 3) The vapour was exchanged between the upper and lower layers via the turbulent exchange and vertical air motion, which mixed the fog density and maintained the thickness of the fog. These mechanisms explain why the fog top was higher than the lower inversion layer and reached the upper inversion layer, as well as why this advection fog was so thick.
NASA Astrophysics Data System (ADS)
Zhang, Dongdong; Tan, Jianguo; Lv, Liang
2015-12-01
The mixing process has been an important issue for the design of supersonic combustion ramjet engine, and the mixing efficiency plays a crucial role in the improvement of the combustion efficiency. In the present study, nanoparticle-based planar laser scattering (NPLS), particle image velocimetry (PIV) and large eddy simulation (LES) are employed to investigate the flow and mixing characteristics of supersonic mixing layer under different forced vibration conditions. The indexes of fractal dimension, mixing layer thickness, momentum thickness and scalar mixing level are applied to describe the mixing process. Results show that different from the development and evolution of supersonic mixing layer without vibration, the flow under forced vibration is more likely to present the characteristics of three-dimensionality. The laminar flow region of mixing layer under forced vibration is greatly shortened and the scales of rolled up Kelvin-Helmholtz vortices become larger, which promote the mixing process remarkably. The fractal dimension distribution reveals that comparing with the flow without vibration, the turbulent fluctuation of supersonic mixing layer under forced vibration is more intense. Besides, the distribution of mixing layer thickness, momentum thickness and scalar mixing level are strongly influenced by forced vibration. Especially, when the forcing frequency is 4000 Hz, the mixing layer thickness and momentum thickness are 0.0391 m and 0.0222 m at the far field of 0.16 m, 83% and 131% higher than that without vibration at the same position, respectively.
Effect of periocular humidity on the tear film lipid layer.
Korb, D R; Greiner, J V; Glonek, T; Esbah, R; Finnemore, V M; Whalen, A C
1996-03-01
The purpose of this study was to determine the relationship between the tear film and humidity by examining whether alterations in periocular humidity influence the thickness of the tear film lipid layer. Thirteen dry eye subjects presenting with a baseline lipid layer thickness of < or = 60 nm were fitted with modified swim goggles in which the right eye (OD) was exposed to conditions of high humidity and the left eye (OS) remained exposed to ambient room conditions. The lipid layer was monitored over a 60-min time course with goggles on and for an additional 60 min following goggle removal. The OD lipid layer increased significantly in thickness within 5 min of exposure to conditions of high humidity (p < 0.0001), reaching a maximum increase of 66.4 nm after 15 min of goggle wear (p < 0.0001). This maximum increase to a lipid layer thickness of 120.5 nm was maintained at the 30- and 60-min goggle time points. No significant change was detected OS. Following goggle removal, OD values declined but remained significantly elevated over the OS lipid layer thickness throughout the 60-min postgoggle period. Moderate to total relief of dry eye symptoms was reported during goggle wear and generally persisted at a reduced level for 1-3 h following goggle removal. Increased periocular humidity results in an increase in tear film lipid layer thickness, possibly by providing an environment that is more conducive to the spreading of meibomian lipid and its incorporation into the tear film.
Drits, Victor A.; Środoń, Jan; Eberl, D.D.
1997-01-01
The standard form of the Scherrer equation, which has been used to calculate the mean thickness of the coherent scattering domain (CSD) of illite crystals from X-ray diffraction (XRD) full width data at half maximum (FWHM) intensity, employs a constant, Ksh, of 0.89. Use of this constant is unjustified, even if swelling has no effect on peak broadening, because this constant is valid only if all CSDs have a single thickness. For different thickness distributions, the Scherrer “constant” has very different values.Analysis of fundamental particle thickness data (transmission electron microscopy, TEM) for samples of authigenic illite and illite/smectite from diagenetically altered pyroclastics and filamentous illites from sandstones reveals a unique family of lognormal thickness distributions for these clays. Experimental relations between the distributions' lognormal parameters and mean thicknesses are established. These relations then are used to calculate the mean thickness of CSDs for illitic samples from XRD FWHM, or from integral XRD peak widths (integrated intensity/maximum intensity).For mixed-layer illite/smectite, the measured thickness of the CSD corresponds to the mean thickness of the mixed-layer crystal. Using this measurement, the mean thickness of the fundamental particles that compose the mixed-layer crystals can be calculated after XRD determination of percent smectitic interlayers. The effect of mixed layering (swelling) on XRD peak width for these samples is eliminated by using the 003 reflection for glycolated samples, and the 001, 002 or 003 reflection for dehydrated, K-saturated samples. If this technique is applied to the 001 reflection of air-dried samples (Kubler index measurement), mean CSD thicknesses are underestimated due to the mixed-layering effect.The technique was calibrated using NEW MOD©-simulated XRD profiles of illite, and then tested on well-characterized illite and illite/smectite samples. The XRD measurements are in good agreement with estimates of the mean thickness of fundamental particles obtained both from TEM measurements and from fixed cations content, up to a mean value of 20 layers. Correction for instrumental broadening under the conditions employed here is unnecessary for this range of thicknesses.
Kim, Eun Kyoung; Park, Hae-Young Lopilly; Park, Chan Kee
2017-01-01
To evaluate the changes of retinal nerve fiber layer (RNFL), ganglion cell layer (GCL), inner plexiform layer (IPL), and ganglion cell-inner plexiform layer (GCIPL) thicknesses and compare structure-function relationships of 4 retinal layers using spectral-domain optical coherence tomography (SD-OCT) in macular region of glaucoma patients. In cross-sectional study, a total of 85 eyes with pre-perimetric to advanced glaucoma and 26 normal controls were enrolled. The glaucomatous eyes were subdivided into three groups according to the severity of visual field defect: a preperimetric glaucoma group, an early glaucoma group, and a moderate to advanced glaucoma group. RNFL, GCL, IPL, and GCIPL thicknesses were measured at the level of the macula by the Spectralis (Heidelberg Engineering, Heidelberg, Germany) SD-OCT with automated segmentation software. For functional evaluation, corresponding mean sensitivity (MS) values were measured using 24-2 standard automated perimetry (SAP). RNFL, GCL, IPL, and GCIPL thicknesses were significantly different among 4 groups (P < .001). Macular structure losses were positively correlated with the MS values of the 24-2 SAP for RNFL, GCL, IPL, and GCIPL (R = 0.553, 0.636, 0.648 and 0.646, respectively, P < .001). In regression analysis, IPL and GCIPL thicknesses showed stronger association with the corresponding MS values of 24-2 SAP compared with RNFL and GCL thicknesses (R2 = 0.420, P < .001 for IPL; R2 = 0.417, P< .001 for GCIPL thickness). Segmented IPL thickness was significantly associated with the degree of glaucoma. Segmental analysis of the inner retinal layer including the IPL in macular region may provide valuable information for evaluating glaucoma.
NASA Technical Reports Server (NTRS)
Hirt, Stefanie M.
2015-01-01
A test was conducted in the 15 cm x 15 cm supersonic wind tunnel at NASA Glenn Research Center that focused on corner effects of an oblique shock-wave/boundary-layer interaction. In an attempt to control the interaction in the corner region, eight corner fillet configurations were tested. Three parameters were considered for the fillet configurations: the radius, the fillet length, and the taper length from the square corner to the fillet radius. Fillets effectively reduced the boundary-layer thickness in the corner; however, there was an associated penalty in the form of increased boundary-layer thickness at the tunnel centerline. Larger fillet radii caused greater reductions in boundary-layer thickness along the corner bisector. To a lesser, but measureable, extent, shorter fillet lengths resulted in thinner corner boundary layers. Overall, of the configurations tested, the largest radius resulted in the best combination of control in the corner, evidenced by a reduction in boundary-layer thickness, coupled with minimal impacts at the tunnel centerline.
Faria, Mun Y; Ferreira, Nuno P; Mano, Sofia; Cristóvao, Diana M; Sousa, David C; Monteiro-Grillo, Manuel E
2018-05-01
To provide a spectral-domain optical coherence tomography (SD-OCT)-based analysis of retinal layers thickness and nasal displacement of closed macular hole after internal limiting membrane peeling in macular hole surgery. In this nonrandomized prospective interventional study, 36 eyes of 32 patients were subjected to pars plana vitrectomy and 3.5 mm diameter internal limiting membrane (ILM) peeling for idiopathic macular hole (IMH). Nasal and temporal internal retinal layer thickness were assessed with SD-OCT. Each scan included optic disc border so that distance between optic disc border and fovea were measured. Thirty-six eyes had a successful surgery with macular hole closure. Total nasal retinal thickening (p<0.001) and total temporal retinal thinning (p<0.0001) were observed. Outer retinal layers increased thickness after surgery (nasal p<0.05 and temporal p<0.01). Middle part of inner retinal layers (mIRL) had nasal thickening (p<0.001) and temporal thinning (p<0.05). The mIRL was obtained by deducting ganglion cell layer (GCL) and retinal nerve fiber layer (RNFL) thickness from overall thickness of the inner retinal layer. Papillofoveal distance was shorter after ILM peeling in macular hole surgery (3,651 ± 323 μm preoperatively and 3,361 ± 279 μm at 6 months; p<0.0001). Internal limiting membrane peel is associated with important alteration in inner retinal layer architecture, with thickening of mIRL and shortening of papillofoveal distance. These factors may contribute to recovery of disrupted foveal photoreceptor and vision improvement after IMH closure.
Villain, Max A; Greenfield, David S
2003-01-01
To assess reproducibility of quadrantic and clock hour sectors of retinal nerve fiber layer thickness in normal eyes using optical coherence tomography. Normal eyes of healthy volunteers meeting eligibility criteria were imaged by two inexperienced operators. Six 360 degrees circular scans with a diameter of 3.4 mm centered on the optic disc were obtained during each scanning session, and a baseline image was formed using 3 high-quality images defined by the software. Images were obtained on three different days within a 4-week period. Variance and coefficient of variation (CV) were calculated for quadrantic and retinal nerve fiber layer clock hour sectors obtained from the baseline image. Five normal eyes were scanned. Intraoperator reproducibility was high. The mean (+/- SD) CV for total retinal nerve fiber layer thickness was 5.3 +/- 3.82% and 4.33 +/- 3.7% for operators 1 and 2, respectively. Interoperator reproducibility was good with statistically similar variance for all quadrantic and clock hour retinal nerve fiber layer parameters (P = .42 to .99). The nasal retinal nerve fiber layer was the most variable sector for both operators (mean CV: 10.42% and 7.83% for operators 1 and 2, respectively). Differences in mean total, nasal, temporal, and superior retinal nerve fiber layer thickness were not statistically significant between operators for all eyes; however, for inferior retinal nerve fiber layer thickness, there was a significant (P = .0007) difference between operators in one eye. Peripapillary retinal nerve fiber layer thickness assessments using optical coherence tomography have good intraoperator and interoperator reproducibility. Inexperienced operators can generate useful measurement data with acceptable levels of variance.
Correlation of CsK 2Sb photocathode lifetime with antimony thickness
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mamun, M. A.; Hernandez-Garcia, C.; Poelker, M.
CsK 2Sb photocathodes with quantum efficiency on the order of 10% at 532 nm, and lifetime greater than 90 days at low voltage, were successfully manufactured via co-deposition of alkali species emanating from an effusion source. Photocathodes were characterized as a function of antimony layer thickness and alkali consumption, inside a vacuum chamber that was initially baked, but frequently vented without re-baking. Photocathode lifetime measured at low voltage is correlated with the antimony layer thickness. Photocathodes manufactured with comparatively thick antimony layers exhibited the best lifetime. We speculate that the antimony layer serves as a reservoir, or sponge, for themore » alkali.« less
Correlation of CsK 2Sb photocathode lifetime with antimony thickness
Mamun, M. A.; Hernandez-Garcia, C.; Poelker, M.; ...
2015-06-10
CsK 2Sb photocathodes with quantum efficiency on the order of 10% at 532 nm, and lifetime greater than 90 days at low voltage, were successfully manufactured via co-deposition of alkali species emanating from an effusion source. Photocathodes were characterized as a function of antimony layer thickness and alkali consumption, inside a vacuum chamber that was initially baked, but frequently vented without re-baking. Photocathode lifetime measured at low voltage is correlated with the antimony layer thickness. Photocathodes manufactured with comparatively thick antimony layers exhibited the best lifetime. We speculate that the antimony layer serves as a reservoir, or sponge, for themore » alkali.« less
Correlation of CsK{sub 2}Sb photocathode lifetime with antimony thickness
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mamun, M. A., E-mail: mmamu001@odu.edu; Elmustafa, A. A.; The Applied Research Center, Thomas Jefferson National Accelerator Facility, Newport News, Virginia 23606
CsK{sub 2}Sb photocathodes with quantum efficiency on the order of 10% at 532 nm, and lifetime greater than 90 days at low voltage, were successfully manufactured via co-deposition of alkali species emanating from an effusion source. Photocathodes were characterized as a function of antimony layer thickness and alkali consumption, inside a vacuum chamber that was initially baked, but frequently vented without re-baking. Photocathode lifetime measured at low voltage is correlated with the antimony layer thickness. Photocathodes manufactured with comparatively thick antimony layers exhibited the best lifetime. We speculate that the antimony layer serves as a reservoir, or sponge, for themore » alkali.« less
Zamani Nejad, Mohammad; Jabbari, Mehdi; Ghannad, Mehdi
2014-01-01
Using disk form multilayers, a semi-analytical solution has been derived for determination of displacements and stresses in a rotating cylindrical shell with variable thickness under uniform pressure. The thick cylinder is divided into disk form layers form with their thickness corresponding to the thickness of the cylinder. Due to the existence of shear stress in the thick cylindrical shell with variable thickness, the equations governing disk layers are obtained based on first-order shear deformation theory (FSDT). These equations are in the form of a set of general differential equations. Given that the cylinder is divided into n disks, n sets of differential equations are obtained. The solution of this set of equations, applying the boundary conditions and continuity conditions between the layers, yields displacements and stresses. A numerical solution using finite element method (FEM) is also presented and good agreement was found.
Zamani Nejad, Mohammad; Jabbari, Mehdi; Ghannad, Mehdi
2014-01-01
Using disk form multilayers, a semi-analytical solution has been derived for determination of displacements and stresses in a rotating cylindrical shell with variable thickness under uniform pressure. The thick cylinder is divided into disk form layers form with their thickness corresponding to the thickness of the cylinder. Due to the existence of shear stress in the thick cylindrical shell with variable thickness, the equations governing disk layers are obtained based on first-order shear deformation theory (FSDT). These equations are in the form of a set of general differential equations. Given that the cylinder is divided into n disks, n sets of differential equations are obtained. The solution of this set of equations, applying the boundary conditions and continuity conditions between the layers, yields displacements and stresses. A numerical solution using finite element method (FEM) is also presented and good agreement was found. PMID:24719582
Impact of small-scale vegetation structure on tephra layer preservation
Cutler, Nick A.; Shears, Olivia M.; Streeter, Richard T.; Dugmore, Andrew J.
2016-01-01
The factors that influence tephra layer taphonomy are poorly understood, but vegetation cover is likely to play a role in the preservation of terrestrial tephra deposits. The impact of vegetation on tephra layer preservation is important because: 1) the morphology of tephra layers could record key characteristics of past land surfaces and 2) vegetation-driven variability in tephra thickness could affect attempts to infer eruption and dispersion parameters. We investigated small- (metre-) scale interactions between vegetation and a thin (<10 cm), recent tephra layer. We conducted surveys of vegetation structure and tephra thickness at two locations which received a similar tephra deposit, but had contrasting vegetation cover (moss vs shrub). The tephra layer was thicker and less variable under shrub cover. Vegetation structure and layer thickness were correlated on the moss site but not under shrub cover, where the canopy reduced the influence of understory vegetation on layer morphology. Our results show that vegetation structure can influence tephra layer thickness on both small and medium (site) scales. These findings suggest that some tephra layers may carry a signal of past vegetation cover. They also have implications for the sampling effort required to reliably estimate the parameters of initial deposits. PMID:27845415
Depth Measurements Using Alpha Particles and Upsettable SRAMs
NASA Technical Reports Server (NTRS)
Buehler, M. G.; Reier, M.; Soli, G. A.
1995-01-01
A custom designed SRAM was used to measure the thickness of integrated circuit over layers and the epi-layer thickness using alpha particles and a test SRAM. The over layer consists of oxide, nitride, metal, and junction regions.
Gait-related strategies for the prevention of plantar ulcer development in the high risk foot.
Bowling, Frank L; Reeves, Neil D; Boulton, Andrew J
2011-05-01
High plantar pressures lead to ulceration in the diabetic foot, particularly in the forefoot region around the metatarsal heads. High plantar pressures persist during gait due to factors such as peripheral neuropathy, foot deformities, limited ankle dorsi flexion range of motion and reduced plantar tissue thickness. Strategies impinging upon gait such as the use of appropriate therapeutic footwear, custom-moulded insoles and injectable silicone can help to reduce plantar pressures and attenuate the risk for ulceration. Shoes adapted with external rocker profiles facilitate plantar flexion and restrict sagittal plane motion of the metatarsophalangeal joint, reducing pressures in the region of the metatarsal heads. Insoles custom-moulded to patient's feet help to reduce plantar pressures and minimise the risk of ulceration in the forefoot region. The loss of subcutaneous fat tissue in the diabetic foot enhances bony prominences and predisposes the foot to high-pressure areas. Silicone is a biocompatible material that can be safely injected into plantar soft tissue to augment tissue thickness and prevent the development of ulceration. This enhancement to the subcutaneous layer is remarkably well retained and is a generally well-adopted procedure in the clinical setting.
Thickness shear mode (TSM) resonators used for biosensing
NASA Astrophysics Data System (ADS)
Bailey, Claude A.; Fiebor, Ben; Yen, Wei; Vodyanoy, Vitaly; Cernosek, Richard W.; Chin, Bryan A.
2002-02-01
The Auburn University Detection and Food Safety Center has demonstrated real-time biosensor for the detection of Salmonella typimhurium, consisting of a thickness shear-mode (TSM) quartz resonator with antibodies immobilized in a Langmuir-Blodgett surface film. Scanning Electron Microscopy (SEM) images of bound Salmonella bacteria to both polished and unpolished TSM resonators were taken to correlate the mass of the bound organism to the Sauerbrey equation. Theoretical frequency shifts for unpolished TSM resonators predicted by the Sauerbrey equation are much smaller than experimentally measured frequency shift. The Salmonella detector operates in a liquid environment. The viscous properties of this liquid overlayer could influence the TSM resonator's response. Various liquid media were studied as a function of temperature (0 to 50 degree(s)C). The chicken exudate samples with varying fat content show coagulation occurring at temperatures above 35 degree(s)C. Kinematic viscosity test were performed with buffer solutions containing varying quantities of Salmonella bacteria. Since the TSM resonators only entrain a boundary layer of fluid near the surface, they do not respond to these background viscous property changes. Bilk viscosity increases when bacteria concentrations are high. This paper describes investigations of TSM resonator surface acoustic interactions - mass, fluid viscosity, and viscoelasticity - that affect the sensor.
Thin Thermal-Insulation Blankets for Very High Temperatures
NASA Technical Reports Server (NTRS)
Choi, Michael K.
2003-01-01
Thermal-insulation blankets of a proposed type would be exceptionally thin and would endure temperatures up to 2,100 C. These blankets were originally intended to protect components of the NASA Solar Probe spacecraft against radiant heating at its planned closest approach to the Sun (a distance of 4 solar radii). These blankets could also be used on Earth to provide thermal protection in special applications (especially in vacuum chambers) for which conventional thermal-insulation blankets would be too thick or would not perform adequately. A blanket according to the proposal (see figure) would be made of molybdenum, titanium nitride, and carbon- carbon composite mesh, which melt at temperatures of 2,610, 2,930, and 2,130 C, respectively. The emittance of molybdenum is 0.24, while that of titanium nitride is 0.03. Carbon-carbon composite mesh is a thermal insulator. Typically, the blanket would include 0.25-mil (.0.00635-mm)-thick hot-side and cold-side cover layers of molybdenum. Titanium nitride would be vapor-deposited on both surfaces of each cover layer. Between the cover layers there would be 10 inner layers of 0.15-mil (.0.0038-mm)-thick molybdenum with vapor-deposited titanium nitride on both sides of each layer. The thickness of each titanium nitride coat would be about 1,000 A. The cover and inner layers would be interspersed with 0.25-mil (0.00635-mm)-thick layers of carbon-carbon composite mesh. The blanket would have total thickness of 4.75 mils (approximately equal to 0.121 mm) and an areal mass density of 0.7 kilograms per square meter. One could, of course, increase the thermal- insulation capability of the blanket by increasing number of inner layers (thereby unavoidably increasing the total thickness and mass density).
Higashide, Tomomi; Ohkubo, Shinji; Hangai, Masanori; Ito, Yasuki; Shimada, Noriaki; Ohno-Matsui, Kyoko; Terasaki, Hiroko; Sugiyama, Kazuhisa; Chew, Paul; Li, Kenneth K W; Yoshimura, Nagahisa
2016-01-01
To identify the factors which significantly contribute to the thickness variabilities in macular retinal layers measured by optical coherence tomography with or without magnification correction of analytical areas in normal subjects. The thickness of retinal layers {retinal nerve fiber layer (RNFL), ganglion cell layer plus inner plexiform layer (GCLIPL), RNFL plus GCLIPL (ganglion cell complex, GCC), total retina, total retina minus GCC (outer retina)} were measured by macular scans (RS-3000, NIDEK) in 202 eyes of 202 normal Asian subjects aged 20 to 60 years. The analytical areas were defined by three concentric circles (1-, 3- and 6-mm nominal diameters) with or without magnification correction. For each layer thickness, a semipartial correlation (sr) was calculated for explanatory variables including age, gender, axial length, corneal curvature, and signal strength index. Outer retinal thickness was significantly thinner in females than in males (sr2, 0.07 to 0.13) regardless of analytical areas or magnification correction. Without magnification correction, axial length had a significant positive sr with RNFL (sr2, 0.12 to 0.33) and a negative sr with GCLIPL (sr2, 0.22 to 0.31), GCC (sr2, 0.03 to 0.17), total retina (sr2, 0.07 to 0.17) and outer retina (sr2, 0.16 to 0.29) in multiple analytical areas. The significant sr in RNFL, GCLIPL and GCC became mostly insignificant following magnification correction. The strong correlation between the thickness of inner retinal layers and axial length appeared to result from magnification effects. Outer retinal thickness may differ by gender and axial length independently of magnification correction.
Higashide, Tomomi; Ohkubo, Shinji; Hangai, Masanori; Ito, Yasuki; Shimada, Noriaki; Ohno-Matsui, Kyoko; Terasaki, Hiroko; Sugiyama, Kazuhisa; Chew, Paul; Li, Kenneth K. W.; Yoshimura, Nagahisa
2016-01-01
Purpose To identify the factors which significantly contribute to the thickness variabilities in macular retinal layers measured by optical coherence tomography with or without magnification correction of analytical areas in normal subjects. Methods The thickness of retinal layers {retinal nerve fiber layer (RNFL), ganglion cell layer plus inner plexiform layer (GCLIPL), RNFL plus GCLIPL (ganglion cell complex, GCC), total retina, total retina minus GCC (outer retina)} were measured by macular scans (RS-3000, NIDEK) in 202 eyes of 202 normal Asian subjects aged 20 to 60 years. The analytical areas were defined by three concentric circles (1-, 3- and 6-mm nominal diameters) with or without magnification correction. For each layer thickness, a semipartial correlation (sr) was calculated for explanatory variables including age, gender, axial length, corneal curvature, and signal strength index. Results Outer retinal thickness was significantly thinner in females than in males (sr2, 0.07 to 0.13) regardless of analytical areas or magnification correction. Without magnification correction, axial length had a significant positive sr with RNFL (sr2, 0.12 to 0.33) and a negative sr with GCLIPL (sr2, 0.22 to 0.31), GCC (sr2, 0.03 to 0.17), total retina (sr2, 0.07 to 0.17) and outer retina (sr2, 0.16 to 0.29) in multiple analytical areas. The significant sr in RNFL, GCLIPL and GCC became mostly insignificant following magnification correction. Conclusions The strong correlation between the thickness of inner retinal layers and axial length appeared to result from magnification effects. Outer retinal thickness may differ by gender and axial length independently of magnification correction. PMID:26814541
Li, Shu-ting; Wang, Xiang-ning; Du, Xin-hua; Wu, Qiang
2017-01-01
Purpose To compare intra-retinal layer thickness measurements between eyes with no or mild diabetic retinopathy (DR) and age-matched controls using Spectralis spectral-domain optical coherence tomography (SD-OCT). Methods Cross-sectional observational analysis study. High-resolution macular volume scans (30° * 25°) were obtained for 133 type 2 diabetes mellitus (T2DM) patients with no DR, 42 T2DM patients with mild DR and 115 healthy controls. The mean thickness was measured in all 9 Early Treatment Diabetic Retinopathy Study (ETDRS) sectors for 8 separate layers, inner retinal layer (IRL), outer retinal layer (ORL) and total retina (TR), after automated segmentation. The ETDRS grid consisted of three concentric circles of 1-, 3-, and 6-mm diameter. The superior, inferior, temporal, and nasal sectors of the 3- and 6-mm circles were respectively designated as S3, I3, T3, and N3 and S6, I6, T6, and N6. Linear regression analyses were conducted to evaluate the associations between the intra-retinal layer thicknesses, age, diabetes duration, fasting blood glucose and HbA1c. Results The mean age and duration of T2DM were 61.1 and 13.7 years, respectively. Although no significant differences in the average TR and ORL volumes were observed among the groups, significant differences were found in the volume and sectorial thicknesses of the inner plexiform layer (IPL), outer plexiform layer (OPL) and IRL among the groups. In particular, the thicknesses of the IPL (S3, T3, S6, I6 and T6 sectors) and the IRL (S6 sector) were decreased in the no-DR group compared with the controls (P < 0.05). The thickness of the OPL (S3, N3, S6 and N6 sectors) was thinner in the no-DR group than in mild DR (P < 0.05). The average IPL thickness was significantly negatively correlated with age and the duration of diabetes. Conclusion The assessment of the intra-retinal layer thickness showed a significant decrease in the IPL and IRL thicknesses in Chinese adults with T2DM, even in the absence of visible microvascular signs of DR. PMID:28493982
2012-01-01
Background Carcass fatness is an important trait in most pig breeding programs. Following market requests, breeding plans for fresh pork consumption are usually designed to reduce carcass fat content and increase lean meat deposition. However, the Italian pig industry is mainly devoted to the production of Protected Designation of Origin dry cured hams: pigs are slaughtered at around 160 kg of live weight and the breeding goal aims at maintaining fat coverage, measured as backfat thickness to avoid excessive desiccation of the hams. This objective has shaped the genetic pool of Italian heavy pig breeds for a few decades. In this study we applied a selective genotyping approach within a population of ~ 12,000 performance tested Italian Large White pigs. Within this population, we selectively genotyped 304 pigs with extreme and divergent backfat thickness estimated breeding value by the Illumina PorcineSNP60 BeadChip and performed a genome wide association study to identify loci associated to this trait. Results We identified 4 single nucleotide polymorphisms with P≤5.0E-07 and additional 119 ones with 5.0E-07
Shin, Il-Hwan; Lee, Woo-Hyuk; Lee, Jong-Joo; Jo, Young-Joon; Kim, Jung-Yeul
2018-02-01
To determine the repeatability of measuring the thickness of the central macula, retinal nerve fiber layer, and ganglion cell-inner plexiform layer (GC-IPL) using spectral domain optical coherence tomography (Cirrus HD-OCT) in eyes with age-related macular degeneration. One hundred and thirty-four eyes were included. The measurement repeatability was assessed by an experienced examiner who performed two consecutive measurements using a 512 × 128 macular cube scan and a 200 × 200 optic disk cube scan. To assess changes in macular morphology in patients with age-related macular degeneration, the patients were divided into the following three groups according to the central macular thickness (CMT): A group, CMT < 200 μm; B group, 200 μm ≤ CMT < 300 μm; and C group, CMT > 300 μm. Measurement repeatability was assessed using test-retest variability, a coefficient of variation, and an intraclass correlation coefficient. The mean measurement repeatability for the central macular, retinal nerve fiber layer, and GC-IPL thickness was high in the B group. The mean measurement repeatability for both the central macula and retinal nerve fiber layer thickness was high in the A and C groups, but was lower for the GC-IPL thickness. The measurement repeatability for GC-IPL thickness was high in the B group, but low in the A group and in the C group. The automated measurement repeatability for GC-IPL thickness was significantly lower in patients with age-related macular degeneration with out of normal CMT range. The effect of changes in macular morphology should be considered when analyzing GC-IPL thicknesses in a variety of ocular diseases.
Alves, João Guilherme; Vasconcelos, Sarita Amorim; de Almeida, Tais Sá; Lages, Raquel; Just, Eduardo
2015-01-01
A rapid catch-up growth in very low birth weight has been associated both with a higher height growth and a higher risk to metabolic disturbances, including insulin resistance and its consequences. Abdominal fat distribution in early postnatal life may play a role in these outcomes and can help in addressing this neonatal dilemma. This study aimed to compare abdominal fat distribution among very low birth weight (VLBW) children with and without rapid catch-up growth. A cohort study followed 86 VLBW (<1500) children born in Brazil, during the first 3 years of life. Rapid catch-up growth was considered as an increased in length >2 Z score during the first year of life. Abdominal subcutaneous and preperitoneal fat thickness was determined by ultrasound. χ²-Test and Student's t-test were used to compare the groups. A total of 79 VLBW children completed the study, of whom 22 (27.8%) showed rapid catch-up growth. Abdominal subcutaneous and preperitoneal fat thickness showed no differences among children with or without rapid catch-up growth at 3.3 mm vs. 3.8 mm, respectively (p=0.79) and 4.0 mm vs. 4.0 mm (p=0.55), respectively. VLBW children with rapid catch-up growth were also taller. Rapid catch-up growth during the first year of life in VLBW children does not seem to change abdominal fat distribution until the third year of life.
Yan, Lin; Nielsen, Forrest H; Sundaram, Sneha; Cao, Jay
2017-04-04
Bone loss occurs in obesity and cancer-associated complications including wasting. This study determined whether a high-fat diet and a deficiency in monocyte chemotactic protein-1 (MCP-1) altered bone structural defects in male C57BL/6 mice with Lewis lung carcinoma (LLC) metastases in lungs. Compared to non-tumor-bearing mice, LLC reduced bone volume fraction, connectivity density, trabecular number, trabecular thickness and bone mineral density and increased trabecular separation in femurs. Similar changes occurred in vertebrae. The high-fat diet compared to the AIN93G diet exacerbated LLC-induced detrimental structural changes; the exacerbation was greater in femurs than in vertebrae. Mice deficient in MCP-1 compared to wild-type mice exhibited increases in bone volume fraction, connectivity density, trabecular number and decreases in trabecular separation in both femurs and vertebrae, and increases in trabecular thickness and bone mineral density and a decrease in structure model index in vertebrae. Lewis lung carcinoma significantly decreased osteocalcin but increased tartrate-resistant acid phosphatase 5b (TRAP 5b) in plasma. In LLC-bearing mice, the high-fat diet increased and MCP-1 deficiency decreased plasma TRAP 5b; neither the high-fat diet nor MCP-1 deficiency resulted in significant changes in plasma concentration of osteocalcin. In conclusion, pulmonary metastasis of LLC is accompanied by detrimental bone structural changes; MCP-1 deficiency attenuates and high-fat diet exacerbates the metastasis-associated bone wasting.
[Factors influencing the measurement of tear film lipid layer thickness with interferometry].
Finis, D; Pischel, N; Borrelli, M; Schrader, S; Geerling, G
2014-06-01
The quantitative measurement of the tear film lipid layer thickness is a relatively new and promising method. However, so far it has not been investigated whether there is a diurnal or a day to day variability and whether certain factors are confounding the measurement of the lipid layer thickness. In three different experimental settings, 10 subjects without known sicca syndrome were examined at three different time points on one day, on three different days and before and after therapeutic expression of the Meibomian glands. As a comparison, the parameters tear film break-up time, tear meniscus height, diagnostic expression of the Meibomian glands and subjective symptoms, determined using the OSDI (ocular surface disease index) questionnaire, were measured. The results of the study showed a smaller variation of the lipid layer thickness measurements during the day and from day to day compared to the tear film break-up time. The expression of the Meibomian glands significantly increased the lipid layer thickness. There was a correlation between the baseline values of tear film break-up time and the lipid layer thickness. Our data showed that the lipid layer thickness as measured with the Lipiview® interferometer appears to be a relatively constant parameter over time. In addition, the expression of the Meibomian glands could be identified as a potential confounding factor. In this study we included only healthy subjects without known sicca syndrome. For the future our findings need to be validated in dry eye patients. Georg Thieme Verlag KG Stuttgart · New York.
Ghate, Deepta A; Holley, Glenn; Dollinger, Harli; Bullock, Joseph P; Markwardt, Kerry; Edelhauser, Henry F
2008-10-01
To evaluate human corneal endothelial mucin layer thickness and ultrastructure after phacoemulsification and irrigation-aspiration with either next generation ophthalmic irrigating solution (NGOIS) or BSS PLUS. Paired human corneas were mounted in an artificial anterior chamber, exposed to 3 minutes of continuous ultrasound (US) at 80% power using the Alcon SERIES 20000 LEGACY surgical system (n = 9) or to 2 minutes of pulsed US at 50% power, 50% of the time at 20 pps using the Alcon INFINITI Vision System (n = 5), and irrigated with 250 mL of either NGOIS or BSS PLUS. A control group of paired corneas did not undergo phacoemulsification or irrigation-aspiration (n = 5). Corneas were divided and fixed for mucin staining or transmission electron microscopy. Mucin layer thickness was measured on the transmission electron microscopy prints. The mucin layer thickness in the continuous phaco group was 0.77 +/- 0.02 microm (mean +/- SE) with NGOIS and 0.51 +/- 0.01 microm with BSS PLUS (t test, P < 0.001). The mucin layer thickness in the pulsed phaco group was 0.79 +/- 0.02 microm with NGOIS and 0.54 +/- 0.01 microm with BSS PLUS (P < 0.001). The mucin layer thickness in the untreated control group was 0.72 +/- 0.02 microm. The endothelial ultrastructure was normal in all corneas. In this in vitro corneal model, NGOIS, due to its lower surface tension and higher viscosity, preserved endothelial mucin layer thickness better than BSS PLUS with both the INFINITI Vision System (pulsed US) and the LEGACY surgical system (continuous US).
New magnetic phase and magnetic coherence in Nd/Sm(001) superlattices
NASA Astrophysics Data System (ADS)
Soriano, S.; Dufour, C.; Dumesnil, K.; Stunault, A.
2006-06-01
In order to investigate magnetic phenomena in Nd and Sm layers separately, resonant x-ray magnetic scattering experiments have been performed to study Nd/Sm(001) superlattices with different relative layers thickness. The samples were grown using molecular beam epitaxy, and optimized to yield dhcp Sm growth and thus a coherent dhcp stacking across the Nd/Sm superlattices. The magnetic phases in Sm layers are very close to the ones evidenced in dhcp thick films. In contrast, the magnetism in Nd layers shows strong differences with the bulk case. In superlattices with a large Sm thickness (>8 nm), no magnetic scattering usually associated with Nd magnetic structure was detected. In superlattices with smaller Sm thickness (<4 nm), new Nd magnetic phases have been observed. A detailed analysis of the propagation of the magnetic structures in the cubic and hexagonal sublattices of both Sm and Nd is presented. Both Sm hexagonal and cubic magnetic phases propagate coherently through 3.7 nm thick Nd layers but remain confined in Sm layers when the Nd layers are 7.1 nm thick. In contrast, the critical Sm thickness allowing a coherent propagation of Nd magnetic order is different for the hexagonal and cubic sublattices above 5 K. Finally, we show that: (i) a spin-density wave and a 4f magnetic order with perpendicular polarization are exclusive on a given crystallographic site (either hexagonal or cubic); (ii) a 4f magnetic order on a crystallographic site does not perturb the establishment of a spin-density wave with a perpendicular polarization on the other site.
NASA Technical Reports Server (NTRS)
Policastro, Steven G. (Inventor); Woo, Dae-Shik (Inventor)
1983-01-01
A self-aligned method of implanting the edges of NMOS/SOS transistors is described. The method entails covering the silicon islands with a thick oxide layer, applying a protective photoresist layer over the thick oxide layer, and exposing the photoresist layer from the underside of the sapphire substrate thereby using the island as an exposure mask. Only the photoresist on the islands' edges will be exposed. The exposed photoresist is then removed and the thick oxide is removed from the islands edges which are then implanted.
Evaluation and analysis of LTPP pavement layer thickness data
DOT National Transportation Integrated Search
2002-07-30
In 2001, the Federal Highway Administration sponsored a study to review pavement layer thickness data for Long Term Pavement Performance (LTPP) sites. The main objective of the study was to assess the quality and completeness of pavement layering inf...
Jeong, Jong Youn; Lim, Seung Taek; Kim, Cheon Jei
2016-01-01
This study was carried out to evaluate the effects of fat level on the microwave cooking properties of ground pork patties with NaCl (1.5%). Ground pork patties were processed from pork hams to achieve fat levels of 10%, 15%, 20%, and 25%, respectively. Each patty was cooked from a thawed state to 75℃ in a microwave oven at full power (700 W). After microwave cooking, protein content, moisture content, fat retention, and shear force values in patties decreased as fat level increased from 10 to 25%. As fat level increased, cooking time decreased but total cooking loss and drip loss were increased, whereas slight differences in diameter reduction and thickness of patties were observed. In raw patties, 10% fat patties had lower L* values and higher a* values compared to patties with more fat, but these differences were reduced when patties were cooked. Patties with 10% fat showed a more pink color on the surface and interior than patties with a higher fat content but more air pockets were noted in higher-fat patties. Higher-fat patties were more tender, juicy, and oily than lower-fat patties. PMID:27621696
NASA Astrophysics Data System (ADS)
Madkour, Sherif; Szymoniak, Paulina; Schick, Christoph; Schönhals, Andreas
2017-05-01
Specific heat spectroscopy (SHS) employing AC nanochip calorimetry was used to investigate the glassy dynamics of ultra-thin films (thicknesses: 10 nm-340 nm) of a polymer blend, which is miscible in the bulk. In detail, a Poly(vinyl methyl ether) (PVME)/Polystyrene (PS) blend with the composition of 25/75 wt. % was studied. The film thickness was controlled by ellipsometry while the film topography was checked by atomic force microscopy. The results are discussed in the framework of the balance between an adsorbed and a free surface layer on the glassy dynamics. By a self-assembling process, a layer with a reduced mobility is irreversibly adsorbed at the polymer/substrate interface. This layer is discussed employing two different scenarios. In the first approach, it is assumed that a PS-rich layer is adsorbed at the substrate. Whereas in the second approach, a PVME-rich layer is suggested to be formed at the SiO2 substrate. Further, due to the lower surface tension of PVME, with respect to air, a nanometer thick PVME-rich surface layer, with higher molecular mobility, is formed at the polymer/air interface. By measuring the glassy dynamics of the thin films of PVME/PS in dependence on the film thickness, it was shown that down to 30 nm thicknesses, the dynamic Tg of the whole film was strongly influenced by the adsorbed layer yielding a systematic increase in the dynamic Tg with decreasing the film thickness. However, at a thickness of ca. 30 nm, the influence of the mobile surface layer becomes more pronounced. This results in a systematic decrease in Tg with the further decrease of the film thickness, below 30 nm. These results were discussed with respect to thin films of PVME/PS blend with a composition of 50/50 wt. % as well as literature results.
Assessment of the growth/etch back technique for the production of Ge strain-relaxed buffers on Si
NASA Astrophysics Data System (ADS)
Hartmann, J. M.; Aubin, J.
2018-04-01
Thick Ge layers grown on Si(0 0 1) are handy for the production of GeOI wafers, as templates for the epitaxy of III-V and GeSn-based heterostructures and so on. Perfecting their crystalline quality would enable to fabricate suspended Ge micro-bridges with extremely high levels of tensile strain (for mid IR lasers). In this study, we have used a low temperature (400 °C)/high temperature (750 °C) approach to deposit with GeH4 various thickness Ge layers in the 0.5 μm - 5 μm range. They were submitted afterwards to short duration thermal cycling under H2 (in between 750 °C and 875-890 °C) to lower the Threading Dislocation Density (TDD). Some of the thickest layers were partly etched at 750 °C with gaseous HCl to recover wafer bows compatible with device processing later on. X-ray Diffraction (XRD) showed that the layers were slightly tensile-strained, with a 104.5-105.5% degree of strain relaxation irrespective of the thickness. The surface was cross-hatched, with a roughness slightly decreasing with the thickness, from 2.0 down to 0.8 nm. The TDD (from Omega scans in XRD) decreased from 8 × 107 cm-2 down to 107 cm-2 as the Ge layer thickness increased from 0.5 up to 5 μm. The lack of improvement when growing 5 μm thick layers then etching a fraction of them with HCl over same thickness layers grown in a single run was at variance with Thin Solid Films 520, 3216 (2012). Low temperature HCl defect decoration confirmed those findings, with (i) a TDD decreasing from slightly more 107 cm-2 down to 5 × 106 cm-2 as the Ge layer thickness increased from 1.3 up to 5 μm and (ii) no TDD hysteresis between growth and growth then HCl etch-back.
Effect of capping layer on interlayer coupling in synthetic spin valves
NASA Astrophysics Data System (ADS)
Li, Kebin; Qiu, Jinjun; Han, Guchang; Guo, Zaibing; Zheng, Yuankai; Wu, Yihong; Li, Jinshan
2005-01-01
The magnetic and transport properties of high quality synthetic spin-valves with the structure of Ta/NiFe/IrMn/CoFe/Ru/CoFe/NOL/CoFe/Cu/CoFe/CL were studied by using magnetoresistance measurements. Here Ti, Hf, and Al are used as the capping layer. It is found that both the thickness and materials properties of the capping layers can affect the interlayer coupling field. The interlayer coupling field oscillates weakly with respect to the thickness of the Ti and Hf capping layers. Extremely strong ferromagnetic coupling has been observed when the thickness of the Al capping layer is in a certain range where resonant exchange coupling takes place. The strength of the interlayer coupling is inversely proportional to the square of the thickness of the spacer. It is a typical characteristic of quantum size effect.
NASA Astrophysics Data System (ADS)
Chen, Biao; Ruth, Chris; Jing, Zhenxue; Ren, Baorui; Smith, Andrew; Kshirsagar, Ashwini
2014-03-01
Breast density has been identified to be a risk factor of developing breast cancer and an indicator of lesion diagnostic obstruction due to masking effect. Volumetric density measurement evaluates fibro-glandular volume, breast volume, and breast volume density measures that have potential advantages over area density measurement in risk assessment. One class of volume density computing methods is based on the finding of the relative fibro-glandular tissue attenuation with regards to the reference fat tissue, and the estimation of the effective x-ray tissue attenuation differences between the fibro-glandular and fat tissue is key to volumetric breast density computing. We have modeled the effective attenuation difference as a function of actual x-ray skin entrance spectrum, breast thickness, fibro-glandular tissue thickness distribution, and detector efficiency. Compared to other approaches, our method has threefold advantages: (1) avoids the system calibration-based creation of effective attenuation differences which may introduce tedious calibrations for each imaging system and may not reflect the spectrum change and scatter induced overestimation or underestimation of breast density; (2) obtains the system specific separate and differential attenuation values of fibroglandular and fat for each mammographic image; and (3) further reduces the impact of breast thickness accuracy to volumetric breast density. A quantitative breast volume phantom with a set of equivalent fibro-glandular thicknesses has been used to evaluate the volume breast density measurement with the proposed method. The experimental results have shown that the method has significantly improved the accuracy of estimating breast density.
NASA Astrophysics Data System (ADS)
Shekhar, Himanshu; Tzabari, Lior; Solomeshch, Olga; Tessler, Nir
2016-10-01
We have investigated the influence of the active layer thickness on the balance of the internal mechanisms affecting the efficiency of copper phthalocyanine - fullerene (C60) based vacuum deposited bulk heterojunction organic photocell. We fabricated a range of devices for which we varied the thickness of the active layer from 40 to 120 nm and assessed their performance using optical and electrical characterization techniques. As reported previously for phthalocyanine:C60, the performance of the device is highly dependent on the active layer thickness and of all the thicknesses we tried, the 40 nm thin active layer device showed the best solar cell characteristic parameters. Using the transfer matrix based optical model, which includes interference effects, we calculated the optical power absorbed in the active layers for the entire absorption band, and we found that this cannot explain the trend with thickness. Measurement of the cell quantum efficiency as a function of light intensity showed that the relative weight of the device internal processes changes when going from 40 nm to 120 nm thick active layer. Electrical modeling of the device, which takes different internal processes into account, allowed to quantify the changes in the processes affecting the generation - recombination balance. Sub gap external quantum efficiency and morphological analysis of the surface of the films agree with the model's result. We found that as the thickness grows the density of charge transfer states and of dark carriers goes up and the uniformity in the vertical direction is reduced.
Huynh, Son C; Wang, Xiu Ying; Rochtchina, Elena; Mitchell, Paul
2006-09-01
To study the distribution of retinal nerve fiber layer (RNFL) thickness by ocular and demographic variables in a population-based study of young children. Population-based cross-sectional study. One thousand seven hundred sixty-five of 2238 (78.9%) eligible 6-year-old children participated in the Sydney Childhood Eye Study between 2003 and 2004. Mean age was 6.7 years (50.9% boys). Detailed examination included cycloplegic autorefraction and measurement of axial length. Retinal nerve fiber layer scans using an optical coherence tomographer were performed with a circular scan pattern of 3.4-mm diameter. Multivariate analyses were performed to examine the distribution of RNFL parameters with gender, ethnicity, axial length, and refraction. Peripapillary RNFL thickness and RNFL(estimated integral) (RNFL(EI)), which measures the total cross-sectional area of ganglion cell axons converging onto the optic nerve head. Peripapillary RNFL thickness and RNFL(EI) were normally distributed. The mean+/-standard deviation RNFL average thickness was 103.7+/-11.4 microm and RNFL(EI) was 1.05+/-0.12 mm2. Retinal nerve fiber layer thickness was least for the temporal quadrant (75.7+/-14.7 microm), followed by the nasal (81.7+/-19.6 microm), inferior (127.8+/-20.5 microm), and superior (129.5+/-20.6 microm) quadrants. Multivariate adjusted RNFL average thickness was marginally greater in boys than in girls (104.7 microm vs. 103.2 microm; P = 0.007) and in East Asian than in white children (107.7 microm vs. 102.7 microm; P<0.0001). The RNFL was thinner with greater axial length (P(trend)<0.0001) and less positive spherical equivalent refractions (P(trend) = 0.004). Retinal nerve fiber layer average thickness and RNFL(EI) followed a normal distribution. Retinal nerve fiber layer thickness varied marginally with gender, but differences were more marked between white and East Asian children. Retinal nerve fiber layer thinning was associated with increasing axial length and less positive refractions.
Effect of the Platinum Electroplated Layer Thickness on the Coatings' Microstructure
NASA Astrophysics Data System (ADS)
Zagula-Yavorska, Maryana; Gancarczyk, Kamil; Sieniawski, Jan
2017-03-01
CMSX 4 and Inconel 625 superalloys were coated by platinum layers (3 and 7 μm thick) in the electroplating process. The heat treatment of platinum layers (at 1,050 ˚C for 2 h) was performed to increase platinum adherence to the superalloys substrate. The diffusion zone obtained on CMSX 4 superalloy (3 and 7 μm platinum thick before heat treatment) consisted of two phases: γ-Ni(Al, Cr) and (Al0.25Pt0.75)Ni3. The diffusion zone obtained on Inconel 625 superalloy (3 μm platinum thick before heat treatment) consisted of the α-Pt(Ni, Cr, Al) phase. Moreover, γ-Ni(Cr, Al) phase was identified. The X-ray diffraction (XRD) results revealed the presence of platinum in the diffusion zone of the heat-treated coating (7 μm platinum thick) on Inconel 625 superalloy. The surface roughness parameter Ra of heat-treated coatings increased with the increase of platinum layers thickness. This was due to the unequal mass flow of platinum and nickel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jincheng; Shi, Chengwu, E-mail: shicw506@foxmail.com; Chen, Junjun
2016-06-15
In this paper, the ultra-thin and high-quality WO{sub 3} compact layers were successfully prepared by spin-coating-pyrolysis method using the tungsten isopropoxide solution in isopropanol. The influence of WO{sub 3} and TiO{sub 2} compact layer thickness on the photovoltaic performance of planar perovskite solar cells was systematically compared, and the interface charge transfer and recombination in planar perovskite solar cells with TiO{sub 2} compact layer was analyzed by electrochemical impedance spectroscopy. The results revealed that the optimum thickness of WO{sub 3} and TiO{sub 2} compact layer was 15 nm and 60 nm. The planar perovskite solar cell with 15 nm WO{submore » 3} compact layer gave a 9.69% average and 10.14% maximum photoelectric conversion efficiency, whereas the planar perovskite solar cell with 60 nm TiO{sub 2} compact layer achieved a 11.79% average and 12.64% maximum photoelectric conversion efficiency. - Graphical abstract: The planar perovskite solar cell with 15 nm WO{sub 3} compact layer gave a 9.69% average and 10.14% maximum photoelectric conversion efficiency, whereas the planar perovskite solar cell with 60 nm TiO{sub 2} compact layer achieved a 11.79% average and 12.64% maximum photoelectric conversion efficiency. Display Omitted - Highlights: • Preparation of ultra-thin and high-quality WO{sub 3} compact layers. • Perovskite solar cell with 15 nm-thick WO{sub 3} compact layer achieved PCE of 10.14%. • Perovskite solar cell with 60 nm-thick TiO{sub 2} compact layer achieved PCE of 12.64%.« less
Xu, Man; Wachters, Arthur J H; van Deelen, Joop; Mourad, Maurice C D; Buskens, Pascal J P
2014-03-10
We present a systematic study of the effect of variation of the zinc oxide (ZnO) and copper indium gallium (di)selenide (CIGS) layer thickness on the absorption characteristics of CIGS solar cells using a simulation program based on finite element method (FEM). We show that the absorption in the CIGS layer does not decrease monotonically with its layer thickness due to interference effects. Ergo, high precision is required in the CIGS production process, especially when using ultra-thin absorber layers, to accurately realize the required thickness of the ZnO, cadmium sulfide (CdS) and CIGS layer. We show that patterning the ZnO window layer can strongly suppress these interference effects allowing a higher tolerance in the production process.
NASA Astrophysics Data System (ADS)
Kim, Nam-Hui; Han, Dong-Soo; Jung, Jinyong; Park, Kwonjin; Swagten, Henk J. M.; Kim, June-Seo; You, Chun-Yeol
2017-10-01
The interfacial Dzyaloshinskii-Moriya interaction (iDMI) and the interfacial perpendicular magnetic anisotropy (iPMA) between a heavy metal and ferromagnet are investigated by employing Brillouin light scattering. With increasing thickness of the heavy-metal (Pt) layer, the iDMI and iPMA energy densities are rapidly enhanced and they saturate for a Pt thickness of 2.4 nm. Since these two individual magnetic properties show the same Pt thickness dependence, this is evidence that the iDMI and iPMA at the interface between the heavy metal and ferromagnet, the physical origin of these phenomena, are effectively enhanced upon increasing the thickness of the heavy-metal layer.
Chen, Kun-Neng; Yang, Cheng-Fu; Wu, Chia-Ching; Chen, Yu-Hsin
2017-01-01
We investigated the structural, optical, and electrical properties of amorphous IGZO/silver/amorphous IGZO (α-IGZO/Ag/α-IGZO) triple-layer structures that were deposited at room temperature on Eagle XG glass and flexible polyethylene terephthalate substrates through the sputtering method. Thin Ag layers with different thicknesses were inserted between two IGZO layers to form a triple-layer structure. Ag was used because of its lower absorption and resistivity. Field emission scanning electron microscopy measurements of the triple-layer structures revealed that the thicknesses of the Ag layers ranged from 13 to 41 nm. The thickness of the Ag layer had a large effect on the electrical and optical properties of the electrodes. The optimum thickness of the Ag metal thin film could be evaluated according to the optical transmittance, electrical conductivity, and figure of merit of the electrode. This study demonstrates that the α-IGZO/Ag/α-IGZO triple-layer transparent electrode can be fabricated with low sheet resistance (4.2 Ω/□) and high optical transmittance (88.1%) at room temperature without postannealing processing on the deposited thin films. PMID:28772586
Enface Thickness Mapping and Reflectance Imaging of Retinal Layers in Diabetic Retinopathy.
Francis, Andrew W; Wanek, Justin; Lim, Jennifer I; Shahidi, Mahnaz
2015-01-01
To present a method for image segmentation and generation of enface thickness maps and reflectance images of retinal layers in healthy and diabetic retinopathy (DR) subjects. High density spectral domain optical coherence tomography (SDOCT) images were acquired in 10 healthy and 4 DR subjects. Customized image analysis software identified 5 retinal cell layer interfaces and generated thickness maps and reflectance images of the total retina (TR), inner retina (IR), outer retina (OR), and the inner segment ellipsoid (ISe) band. Thickness maps in DR subjects were compared to those of healthy subjects by generating deviation maps which displayed retinal locations with thickness below, within, and above the normal 95% confidence interval. In healthy subjects, TR and IR thickness maps displayed the foveal depression and increased thickness in the parafoveal region. OR and ISe thickness maps showed increased thickness at the fovea, consistent with normal retinal anatomy. In DR subjects, thickening and thinning in localized regions were demonstrated on TR, IR, OR, and ISe thickness maps, corresponding to retinal edema and atrophy, respectively. TR and OR reflectance images showed reduced reflectivity in regions of increased thickness. Hard exudates appeared as hyper-reflective spots in IR reflectance images and casted shadows on the deeper OR and ISe reflectance images. The ISe reflectance image clearly showed the presence of focal laser scars. Enface thickness mapping and reflectance imaging of retinal layers is a potentially useful method for quantifying the spatial and axial extent of pathologies due to DR.
Enface Thickness Mapping and Reflectance Imaging of Retinal Layers in Diabetic Retinopathy
Francis, Andrew W.; Wanek, Justin; Lim, Jennifer I.; Shahidi, Mahnaz
2015-01-01
Purpose To present a method for image segmentation and generation of enface thickness maps and reflectance images of retinal layers in healthy and diabetic retinopathy (DR) subjects. Methods High density spectral domain optical coherence tomography (SDOCT) images were acquired in 10 healthy and 4 DR subjects. Customized image analysis software identified 5 retinal cell layer interfaces and generated thickness maps and reflectance images of the total retina (TR), inner retina (IR), outer retina (OR), and the inner segment ellipsoid (ISe) band. Thickness maps in DR subjects were compared to those of healthy subjects by generating deviation maps which displayed retinal locations with thickness below, within, and above the normal 95% confidence interval. Results In healthy subjects, TR and IR thickness maps displayed the foveal depression and increased thickness in the parafoveal region. OR and ISe thickness maps showed increased thickness at the fovea, consistent with normal retinal anatomy. In DR subjects, thickening and thinning in localized regions were demonstrated on TR, IR, OR, and ISe thickness maps, corresponding to retinal edema and atrophy, respectively. TR and OR reflectance images showed reduced reflectivity in regions of increased thickness. Hard exudates appeared as hyper-reflective spots in IR reflectance images and casted shadows on the deeper OR and ISe reflectance images. The ISe reflectance image clearly showed the presence of focal laser scars. Conclusions Enface thickness mapping and reflectance imaging of retinal layers is a potentially useful method for quantifying the spatial and axial extent of pathologies due to DR. PMID:26699878
Characteristics of blue organic light emitting diodes with different thick emitting layers
NASA Astrophysics Data System (ADS)
Li, Chong; Tsuboi, Taiju; Huang, Wei
2014-08-01
We fabricated blue organic light emitting diodes (called blue OLEDs) with emitting layer (EML) of diphenylanthracene derivative 9,10-di(2-naphthyl)anthracene (ADN) doped with blue-emitting DSA-ph (1-4-di-[4-(N,N-di-phenyl)amino]styryl-benzene) to investigate how the thickness of EML and hole injection layer (HIL) influences the electroluminescence characteristics. The driving voltage was observed to increase with increasing EML thickness from 15 nm to 70 nm. The maximum external quantum efficiency of 6.2% and the maximum current efficiency of 14 cd/A were obtained from the OLED with 35 nm thick EML and 75 nm thick HIL. High luminance of 120,000 cd/m2 was obtained at 7.5 V from OLED with 15 nm thick EML.
Casimir Pressure in Mds-Structures
NASA Astrophysics Data System (ADS)
Yurova, V. A.; Bukina, M. N.; Churkin, Yu. V.; Fedortsov, A. B.; Klimchitskaya, G. L.
2012-07-01
The Casimir pressure on the dielectric layer in metal-dielectric-semiconductor (MDS) structures is calculated in the framework of the Lifshitz theory at nonzero temperature. In this calculation the standard parameters of semiconductor devices with a thin dielectric layer are used. We consider the thickness of a layer decreasing from 40 to 1 nm. At the shortest thickness the Casimir pressure achieves 8 MPa. At small thicknesses the results are compared with the predictions of nonrelativistic theory.
Method to control residual stress in a film structure and a system thereof
Parthum, Sr., Michael J.
2008-12-30
A method for controlling residual stress in a structure in a MEMS device and a structure thereof includes selecting a total thickness and an overall equivalent stress for the structure. A thickness for each of at least one set of alternating first and second layers is determined to control an internal stress with respect to a neutral axis for each of the at least alternating first and second layers and to form the structure based on the selected total thickness and the selected overall equivalent stress. Each of the at least alternating first and second layers is deposited to the determined thickness for each of the at least alternating first and second layers to form the structure.
Prediction of Layer Thickness in Molten Borax Bath with Genetic Evolutionary Programming
NASA Astrophysics Data System (ADS)
Taylan, Fatih
2011-04-01
In this study, the vanadium carbide coating in molten borax bath process is modeled by evolutionary genetic programming (GEP) with bath composition (borax percentage, ferro vanadium (Fe-V) percentage, boric acid percentage), bath temperature, immersion time, and layer thickness data. Five inputs and one output data exist in the model. The percentage of borax, Fe-V, and boric acid, temperature, and immersion time parameters are used as input data and the layer thickness value is used as output data. For selected bath components, immersion time, and temperature variables, the layer thicknesses are derived from the mathematical expression. The results of the mathematical expressions are compared to that of experimental data; it is determined that the derived mathematical expression has an accuracy of 89%.
NASA Astrophysics Data System (ADS)
Yazdanfar, M.; Stenberg, P.; Booker, I. D.; Ivanov, I. G.; Kordina, O.; Pedersen, H.; Janzén, E.
2013-10-01
The development of a chemical vapor deposition (CVD) process for very thick silicon carbide (SiC) epitaxial layers suitable for high power devices is demonstrated by epitaxial growth of 200 μm thick, low doped 4H-SiC layers with excellent morphology at growth rates exceeding 100 μm/h. The process development was done in a hot wall CVD reactor without rotation using both SiCl4 and SiH4+HCl precursor approaches to chloride based growth chemistry. A C/Si ratio <1 and an optimized in-situ etch are shown to be the key parameters to achieve 200 μm thick, low doped epitaxial layers with excellent morphology.
Simulation and analysis of Au-MgF2 structure in plasmonic sensor in near infrared spectral region
NASA Astrophysics Data System (ADS)
Sharma, Anuj K.
2018-05-01
Plasmonic sensor based on metal-dielectric combination of gold and MgF2 layers is studied in near infrared (NIR) spectral region. An emphasis is given on the effect of variable thickness of MgF2 layer in combination with operating wavelength and gold layer thickness on the sensor's performance in NIR. It is established that the variation in MgF2 thickness in connection with plasmon penetration depth leads to significant variation in sensor's performance. The analysis leads to a conclusion that taking smaller values of MgF2 layer thickness and operating at longer NIR wavelength leads to enhanced sensing performance. Also, fluoride glass can provide better sensing performance than chalcogenide glass and silicon substrate.
Correlation between active layer thickness and ambient gas stability in IGZO thin-film transistors
NASA Astrophysics Data System (ADS)
Gao, Xu; Lin, Meng-Fang; Mao, Bao-Hua; Shimizu, Maki; Mitoma, Nobuhiko; Kizu, Takio; Ou-Yang, Wei; Nabatame, Toshihide; Liu, Zhi; Tsukagoshi, Kazuhito; Wang, Sui-Dong
2017-01-01
Decreasing the active layer thickness has been recently reported as an alternative way to achieve fully depleted oxide thin-film transistors for the realization of low-voltage operations. However, the correlation between the active layer thickness and device resistivity to environmental changes is still unclear, which is important for the optimized design of oxide thin-film transistors. In this work, the ambient gas stability of IGZO thin-film transistors is found to be strongly correlated to the IGZO thickness. The TFT with the thinnest IGZO layer shows the highest intrinsic electron mobility in a vacuum, which is greatly reduced after exposure to O2/air. The device with a thick IGZO layer shows similar electron mobility in O2/air, whereas the mobility variation measured in the vacuum is absent. The thickness dependent ambient gas stability is attributed to a high-mobility region in the IGZO surface vicinity with less sputtering-induced damage, which will become electron depleted in O2/air due to the electron transfer to adsorbed gas molecules. The O2 adsorption and deduced IGZO surface band bending is demonstrated by the ambient-pressure x-ray photoemission spectroscopy results.
Influence of water layer thickness on hard tissue ablation with pulsed CO2 laser
NASA Astrophysics Data System (ADS)
Zhang, Xianzeng; Zhan, Zhenlin; Liu, Haishan; Zhao, Haibin; Xie, Shusen; Ye, Qing
2012-03-01
The theory of hard tissue ablation reported for IR lasers is based on a process of thermomechanical interaction, which is explained by the absorption of the radiation in the water component of the tissue. The microexplosion of the water is the cause of tissue fragments being blasted from hard tissue. The aim of this study is to evaluate the influence of the interdependence of water layer thickness and incident radiant exposure on ablation performance. A total of 282 specimens of bovine shank bone were irradiated with a pulse CO2 laser. Irradiation was carried out in groups: without a water layer and with a static water layer of thickness ranging from 0.2 to 1.2 mm. Each group was subdivided into five subgroups for different radiant exposures ranging from 18 to 84 J/cm2, respectively. The incision geometry, surface morphology, and microstructure of the cut walls as well as thermal injury were examined as a function of the water layer thickness at different radiant exposures. Our results demonstrate that the additional water layer is actually a mediator of laser-tissue interaction. There exists a critical thickness of water layer for a given radiant exposure, at which the additional water layer plays multiple roles, not only acting as a cleaner to produce a clean cut but also as a coolant to prevent bone heating and reduce thermal injury, but also helping to improve the regularity of the cut shape, smooth the cut surface, and enhance ablation rate and efficiency. The results suggest that desired ablation results depend on optimal selection of both water layer thickness and radiant exposure.
Yoon, Chang Ki; Yu, Hyeong Gon
2018-03-01
To investigate how macular ganglion cell-inner plexiform layer (GCIPL) and retinal nerve fibre layer (RNFL) thicknesses within the macula change with retinitis pigmentosa (RP) severity. Spectral domain optical coherence tomography (SD-OCT) was used to examine 177 patients with RP and 177 normal controls. An optical coherence tomography (OCT) line scan was used to grade RP severity. Retinitis pigmentosa (RP) was categorized as more advanced if there was no identifiable inner segment ellipsoid (ISe) band (NISE) and as less advanced if an ISe band could be identified and peripheral loss of ISe was apparent (IISE). Ganglion cell-inner plexiform layer (GCIPL) and RNFL thicknesses were manually measured on OCT images and analysed. Pearson's correlation analyses were used to examine correlations between GCIPL thickness, RNFL thickness, visual acuity (VA) and visual field extent in patients and controls. Ganglion cell-inner plexiform layer (GCIPL) was significantly thicker in IISE than in control eyes (p < 0.001), but significantly thinner in NISE than in IISE eyes (p < 0.001) in both horizontal and vertical OCT scans. Retinal nerve fibre layer (RNFL) was significantly thicker in eyes with IISE and NISE than in control eyes in both horizontal and vertical meridians (all p < 0.001). Ganglion cell-inner plexiform layer (GCIPL) thickness showed a weak positive correlation with vision, and RNFL thickness showed a weak negative correlation with vision and visual field extent. Based on these results, the inner retina, including the GCIPL and RNFL, maintains its gross integrity longer than the photoreceptor layer in RP. Additionally, thickening of the inner retina may have some functional implications in patients with RP. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Thermally stable diamond brazing
Radtke, Robert P [Kingwood, TX
2009-02-10
A cutting element and a method for forming a cutting element is described and shown. The cutting element includes a substrate, a TSP diamond layer, a metal interlayer between the substrate and the diamond layer, and a braze joint securing the diamond layer to the substrate. The thickness of the metal interlayer is determined according to a formula. The formula takes into account the thickness and modulus of elasticity of the metal interlayer and the thickness of the TSP diamond. This prevents the use of a too thin or too thick metal interlayer. A metal interlayer that is too thin is not capable of absorbing enough energy to prevent the TSP diamond from fracturing. A metal interlayer that is too thick may allow the TSP diamond to fracture by reason of bending stress. A coating may be provided between the TSP diamond layer and the metal interlayer. This coating serves as a thermal barrier and to control residual thermal stress.
NASA Astrophysics Data System (ADS)
Han, Dandan; Yan, Yancui; Wei, Jishi; Wang, Biwei; Li, Tongtao; Guo, Guannan; Yang, Dong; Xie, Songhai; Dong, Angang
2017-12-01
Because of their unique physical properties, three-dimensional (3D) graphene has attracted enormous attention over the past years. However, it is still a challenge to precisely control the layer thickness of 3D graphene. Here, we report a novel strategy to rationally adjust the wall thickness of ordered mesoporous graphene (OMG). By taking advantage of ligand exchange capability of colloidal Fe3O4 nanocrystals, we are able to fine-tune the wall thickness of OMG from 2 to 6 layers of graphene by tailoring the hydrocarbon ligands attached to the nanocrystal surface. When evaluated as electrocatalyst for oxygen reduction reaction upon S and N doping, the 4-layer OMG is found to show better catalytic performance compared with its 2- and 6-layer counterparts, which we attribute to the enhanced exposure of active sites resulting from its ultrathin wall thickness and high surface area.
Body shaping with acoustic wave therapy AWT(®)/EPAT(®): randomized, controlled study on 14 subjects.
Adatto, Maurice A; Adatto-Neilson, Robin; Novak, Pavel; Krotz, Alexander; Haller, Gerd
2011-12-01
Reduction of localised adiposities by non invasive means is a very frequent request among the female and male population. The objective of this study is to demonstrate the efficacy and safety of AWT(®), combining two different mechanical waves, planar AWT and radial AWT during the same session, in volume reduction of saddle bags in women. Treatment was performed on the saddle bag areas of 14 female patients, with the CELLACTOR(®) SC1 (Storz Medical AG, Tägerwilen, Switzerland) using extracorporeal pulse activation technology, EPAT(®). This device includes two handpieces, the C-ACTOR(®) and the D-ACTOR(®). Within 4 weeks, eight AWT(®) treatment sessions have been performed with both applicators. Follow-up visits were performed 1, 4 and 12 weeks after the last treatment. Measurements with the ultrasound system clearly demonstrate a significant diminution in the subcutaneous fat layer thickness and a reduction of the averaged circumference of thighs. This study, although performed on a small number of patients, tends to show the safety and efficacy of AWT(®) in treating localized fat areas in a non-invasive way. There is also an additional benefit for patients in reducing the cellulite appearance and improving the skin firmness at the same time by using AWT(®).
High energy PIXE: A tool to characterize multi-layer thick samples
NASA Astrophysics Data System (ADS)
Subercaze, A.; Koumeir, C.; Métivier, V.; Servagent, N.; Guertin, A.; Haddad, F.
2018-02-01
High energy PIXE is a useful and non-destructive tool to characterize multi-layer thick samples such as cultural heritage objects. In a previous work, we demonstrated the possibility to perform quantitative analysis of simple multi-layer samples using high energy PIXE, without any assumption on their composition. In this work an in-depth study of the parameters involved in the method previously published is proposed. Its extension to more complex samples with a repeated layer is also presented. Experiments have been performed at the ARRONAX cyclotron using 68 MeV protons. The thicknesses and sequences of a multi-layer sample including two different layers of the same element have been determined. Performances and limits of this method are presented and discussed.
Method of Fabricating Schottky Barrier solar cell
NASA Technical Reports Server (NTRS)
Stirn, R. J.; Yeh, Y. C. M. (Inventor)
1982-01-01
On a thin substrate of low cost material with at least the top surface of the substrate being electrically conductive is deposited a thin layer of heavily doped n-type polycrystalline germanium, with crystalline sizes in the submicron range. A passivation layer may be deposited on the substrate to prevent migration of impurities into the polycrystalline germanium. The polycrystalline germanium is recrystallized to increase the crystal sizes in the germanium layer to not less than 5 micros to serve as a base layer on which a thin layer of gallium arsenide is vapor epitaxially grown to a selected thickness. A thermally-grown oxide layer of a thickness of several tens of angstroms is formed on the gallium arsenide layer. A metal layer, of not more about 100 angstroms thick, is deposited on the oxide layer, and a grid electrode is deposited to be in electrical contact with the top surface of the metal layer. An antireflection coating may be deposited on the exposed top surface of the metal layer.
First high-resolution stratigraphic column of the Martian north polar layered deposits
Fishbaugh, K.E.; Hvidberg, C.S.; Byrne, S.; Russell, P.S.; Herkenhoff, K. E.; Winstrup, M.; Kirk, R.
2010-01-01
This study achieves the first high-spatial-resolution, layer-scale, measured stratigraphic column of the Martian north polar layered deposits using a 1m-posting DEM. The marker beds found throughout the upper North Polar Layered Deposits range in thickness from 1.6 m-16.0 m +/-1.4 m, and 6 of 13 marker beds are separated by ???25-35 m. Thin-layer sets have average layer separations of 1.6 m. These layer separations may account for the spectral-power-peaks found in previous brightness-profile analyses. Marker-bed layer thicknesses show a weak trend of decreasing thickness with depth that we interpret to potentially be the result of a decreased accumulation rate in the past, for those layers. However, the stratigraphic column reveals that a simple rhythmic or bundled layer sequence is not immediately apparent throughout the column, implying that the relationship between polar layer formation and cyclic climate forcing is quite complex. Copyright ?? 2010 by the American Geophysical Union.
First high-resolution stratigraphic column of the Martian north polar layered deposits
NASA Astrophysics Data System (ADS)
Fishbaugh, Kathryn E.; Hvidberg, Christine S.; Byrne, Shane; Russell, Patrick S.; Herkenhoff, Kenneth E.; Winstrup, Mai; Kirk, Randolph
2010-04-01
This study achieves the first high-spatial-resolution, layer-scale, measured stratigraphic column of the Martian north polar layered deposits using a 1m-posting DEM. The marker beds found throughout the upper North Polar Layered Deposits range in thickness from 1.6 m-16.0 m +/- 1.4 m, and 6 of 13 marker beds are separated by ˜25-35 m. Thin-layer sets have average layer separations of 1.6 m. These layer separations may account for the spectral-power-peaks found in previous brightness-profile analyses. Marker-bed layer thicknesses show a weak trend of decreasing thickness with depth that we interpret to potentially be the result of a decreased accumulation rate in the past, for those layers. However, the stratigraphic column reveals that a simple rhythmic or bundled layer sequence is not immediately apparent throughout the column, implying that the relationship between polar layer formation and cyclic climate forcing is quite complex.
Thermogenic profiling using magnetic resonance imaging of dermal and other adipose tissues
Kasza, Ildiko; Hernando, Diego; Roldán-Alzate, Alejandro; Alexander, Caroline M.; Reeder, Scott B.
2016-01-01
Dermal white adipose tissue (dWAT) was recently recognized for its potential to modify whole body metabolism. Here, we show that dWAT can be quantified using a high-resolution, fat-specific magnetic resonance imaging (MRI) technique. Noninvasive MRI has been used to describe adipocyte depots for many years; the MRI technique we describe uses an advanced fat-specific method to measure the thickness of dWAT, together with the total volume of WAT and the relative activation/fat depletion of brown adipose tissues (BAT). Since skin-embedded adipocytes may provide natural insulation, they provide an important counterpoint to the activation of thermogenic brown and beige adipose tissues, whereby these distinct depots are functionally interrelated and require simultaneous assay. This method was validated using characterized mouse cohorts of a lipodystrophic, dWAT-deficient strain (syndecan-1 KO) and 2 obese models (diet-induced obese mice and genetically obese animals, ob/ob). Using a preliminary cohort of normal human subjects, we found the thickness of skin-associated fat varied 8-fold, from 0.13–1.10 cm; on average, this depot is calculated to weigh 8.8 kg. PMID:27668285
Dutheil, Frédéric; Lac, Gérard; Lesourd, Bruno; Chapier, Robert; Walther, Guillaume; Vinet, Agnès; Sapin, Vincent; Verney, Julien; Ouchchane, Lemlih; Duclos, Martine; Obert, Philippe; Courteix, Daniel
2013-10-09
Opinions differ over the exercise modalities that best limit cardiovascular risk (CVR) resulting from visceral obesity in individuals with metabolic syndrome (MetS). As little is known about the combined effects of resistance and endurance training at high volumes under sound nutritional conditions, we aimed to analyze the impact of various intensities of physical activity on visceral fat and CVR in individuals with MetS. 100 participants, aged 50-70 years, underwent a diet restriction (protein intake 1.2g/kg/day) with a high exercise volume (15-20 h/week). They were randomized to three training groups: moderate-resistance-moderate-endurance (re), high-resistance-moderate-endurance (Re), or moderate-resistance-high-endurance (rE). A one-year at-home follow-up (M12) commenced with a three-week residential program (Day 0 to Day 21). We measured the change in visceral fat and body composition by DXA, MetS parameters, fitness, the Framingham score and carotid-intima-media-thickness. 78 participants completed the program. At D21, visceral fat loss was highest in Re (-18%, p<.0001) and higher in rE than re (-12% vs. -7%, p<.0001). Similarly, from M3, visceral fat decreased more in high-intensity-groups to reach a visceral fat loss of -21.5% (Re) and -21.1% (rE)>-13.0% (re) at M12 (p<.001). CVR, MetS parameters and fitness improved in all groups. Visceral fat loss correlated with changes in MetS parameters. Increased intensity in high volume training is efficient in improving visceral fat loss and carotid-intima-media-thickness, and is realistic in community dwelling, moderately obese individuals. High-intensity-resistance training induced a faster visceral fat loss, and thus the potential of resistance training should not be undervalued (ClinicalTrials.gov number: NCT00917917). Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Carcass classification in suckling lambs. Discrimination ability of the European Union scale.
Miguel, E; Onega, E; Cañeque, V; Velasco, S; Díaz, M T; Lauzurica, S; Pérez, C; Blázquez, B; Ruiz de Huidobro, F
2003-01-01
Forty-nine Manchega suckling lambs were used in this trial. Lambs were slaughtered at 10, 12 and 14 kg liveweight (cold carcass weight lower than 13 kg). The degree of fatness was assessed by three assessors on colour photographs of the carcasses, using the European Union scale for light lambs (EU), and another new scale developed in our laboratory (Suckling Lamb scale, SL). Carcass degree of fatness was reassessed using the same scales divided into 0.25 point-intervals (EUI, SLI). Carcasses were allocated into four groups by means of a tree classification algorithm (cluster analysis), according to 27 variates, namely muscle percentage, whole fat percentage, subcutaneous fat, intermuscular fat, kidney knob and channel fat percentage and muscle percentage, both in the carcass and in three joints (leg, best end neck plus loin, and shoulder). SL scale groups showed a higher number of variates well correlated to assessors' scoring than EU scale groups. Nevertheless, the EU scale showed significant between-groups differences in a higher number of variates (P<0.01). Using 0.25-points interval scales, EUI scale scoring was the best correlated to tissue composition. However, most variates were better correlated to dorsal fat thickness measurement (4 cm back from last rib and 4 cm from the carcass midline) than to assessors' scoring. All four groups in the tree classification were statistically different from one another, but assessors only were able to detect differences between whole fat percentage in group 1 and the rest. These results suggest that it is possible to improve the photographic standards of the EU method by using a 0.25 points interval scale. In abattoir conditions, the new SL method (1.0 point intervals) proved to be better. Measure of dorsal fat thickness proved to be a very good predictor of carcass tissue composition, but it is a more expensive measure.
Magnetic and electrical properties of FeSi/FeSi-ZrO 2 multilayers prepared by EB-PVD
NASA Astrophysics Data System (ADS)
Bi, Xiaofang; Lan, Weihua; Ou, Shengquan; Gong, Shengkai; Xu, Huibin
2003-04-01
FeSi/FeSi-ZrO 2 and FeSi/ZrO 2 multilayer materials were prepared by electron beam physical vapor deposition with the FeSi-ZrO 2 layer thickness about 0.6 μm, and their magnetic and electrical properties were studied as a function of FeSi layer thickness. With increasing FeSi layer thickness from 0.3 to 3 μm, the coercivity decreased from 0.92 to 0.31 kA/m and the saturation magnetization changed from 164 to 186 emu/g. The effect of the layer number on the magnetic properties was discussed in terms of interfacial mixing and oxidation. It was also discovered that the magnetic properties of the multilayer materials were affected by the spacer material, exhibiting higher saturation magnetization and lower coercivity for the FeSi/FeSi-ZrO 2 than those for the FeSi/ZrO 2 with the same individual layer thicknesses. This behavior could be explained by the weaker magnetic interaction between FeSi layers separated by the non-magnetic ZrO 2 layer. Furthermore, the electrical resistivity changed from 1850 to 1250 μΩ cm for the multilayer materials for the FeSi thickness increasing from 0.30 to 3 μm.
NASA Technical Reports Server (NTRS)
Treiman, Allan H.; Fuks, Kelly H.; Murchie, Scott
1995-01-01
A packet of relatively resistant layers, totaling approx. 400 m thickness, is present at the tops of the chasma walls throughout Valles Marineris. The packet consists of an upper dark layer (approx. 50 m thick), a central bright layer (approx. 250 m thick), and a lower dark layer (approx. 100 m thick). The packet appears continuous and of nearly constant thickness and depth below ground surface over the whole Valles system (4000 km E-W, 800 km N-S), independent of elevation (3-10 km) and age of plateau surface (Noachian through upper Hesperian). The packet continues undisturbed beneath the boundary between surface units of Noachian and Hesperian ages, and continues undisturbed beneath impact craters transected by chasma walls. These attributes are not consistent with layer formation by volcanic or sedimentary deposition, and are consistent with layer formation in situ, i.e., by diagenesis, during or after upper Hesperian time. Diagenesis seems to require the action of aqueous solutions in the near subsurface, which are not now stable in the Valles Marineris area. To permit the stability of aqueous solutions, Mars must have had a fairly dense atmosphere, greater than or equal to 1 bar CO2, when the layers formed. Obliquity variations appear to be incapable of producing such a massive atmosphere so late in Mars' history.
Spin-valve Josephson junctions for cryogenic memory
NASA Astrophysics Data System (ADS)
Niedzielski, Bethany M.; Bertus, T. J.; Glick, Joseph A.; Loloee, R.; Pratt, W. P.; Birge, Norman O.
2018-01-01
Josephson junctions containing two ferromagnetic layers are being considered for use in cryogenic memory. Our group recently demonstrated that the ground-state phase difference across such a junction with carefully chosen layer thicknesses could be controllably toggled between zero and π by switching the relative magnetization directions of the two layers between the antiparallel and parallel configurations. However, several technological issues must be addressed before those junctions can be used in a large-scale memory. Many of these issues can be more easily studied in single junctions, rather than in the superconducting quantum interference device (SQUID) used for phase-sensitive measurements. In this work, we report a comprehensive study of spin-valve junctions containing a Ni layer with a fixed thickness of 2.0 nm and a NiFe layer of thickness varying between 1.1 and 1.8 nm in steps of 0.1 nm. We extract the field shift of the Fraunhofer patterns and the critical currents of the junctions in the parallel and antiparallel magnetic states, as well as the switching fields of both magnetic layers. We also report a partial study of similar junctions containing a slightly thinner Ni layer of 1.6 nm and the same range of NiFe thicknesses. These results represent the first step toward mapping out a "phase diagram" for phase-controllable spin-valve Josephson junctions as a function of the two magnetic layer thicknesses.
4P-NPD ultra-thin films as efficient exciton blocking layers in DBP/C70 based organic solar cells
NASA Astrophysics Data System (ADS)
Patil, Bhushan R.; Liu, Yiming; Qamar, Talha; Rubahn, Horst-Günter; Madsen, Morten
2017-09-01
Exciton blocking effects from ultra-thin layers of N,N‧-di-1-naphthalenyl-N,N‧-diphenyl [1,1‧:4‧,1″:4″,1‴-quaterphenyl]-4,4‴-diamine (4P-NPD) were investigated in small molecule-based inverted organic solar cells (OSCs) using tetraphenyldibenzoperiflanthene as the electron donor material and fullerene (C70) as the electron acceptor material. The short-circuit current density (J SC) and power conversion efficiency (PCE) of the optimized OSCs with 0.7 nm thick 4P-NPD were approximately 16% and 24% higher, respectively, compared to reference devices without exciton blocking layers (EBLs). Drift diffusion-based device modeling was conducted to model the full current density-voltage (JV) characteristics and external quantum efficiency spectrum of the OSCs, and photoluminescence measurements were conducted to investigate the exciton blocking effects with increasing thicknesses of the 4P-NPD layer. Importantly, coupled optical and electrical modeling studies of the device behaviors and exciton generation rates and densities in the active layer for different 4P-NPD layer thicknesses were conducted, in order to gain a complete understanding of the observed increase in PCE for 4P-NPD layer thicknesses up to 1 nm, and the observed decrease in PCE for layer thicknesses beyond 1 nm. This work demonstrates a route for guiding the integration of EBLs in OSC devices.
High efficiency organic photovoltaic cells employing hybridized mixed-planar heterojunctions
Xue, Jiangeng; Uchida, Soichi; Rand, Barry P.; Forrest, Stephen
2015-08-18
A device is provided, having a first electrode, a second electrode, and a photoactive region disposed between the first electrode and the second electrode. The photoactive region includes a first photoactive organic layer that is a mixture of an organic acceptor material and an organic donor material, wherein the first photoactive organic layer has a thickness not greater than 0.8 characteristic charge transport lengths; a second photoactive organic layer in direct contact with the first organic layer, wherein the second photoactive organic layer is an unmixed layer of the organic acceptor material of the first photoactive organic layer, and the second photoactive organic layer has a thickness not less than about 0.1 optical absorption lengths; and a third photoactive organic layer disposed between the first electrode and the second electrode and in direct contact with the first photoactive organic layer. The third photoactive organic layer is an unmixed layer of the organic donor layer of the first photoactive organic layer and has a thickness not less than about 0.1 optical absorption lengths.
Superconducting and Magnetic Properties of Vanadium/iron Superlattices.
NASA Astrophysics Data System (ADS)
Wong, Hong-Kuen
A novel ultrahigh vacuum evaporator was constructed for the preparation of superlattice samples. The thickness control was much better than an atomic plane. With this evaporator we prepared V/Fe superlattice samples on (0001) sapphire substrates with different thicknesses. All samples showed a good bcc(110) structure. Mossbauer experiments showed that the interface mixing extended a distance of about one atomic plane indicating an almost rectangular composition profile. Because of this we were able to prepare samples with layer thickness approaching one atomic plane. Even with ultrathin Fe layers, the samples are ferromagnetic, at least at lower temperatures. Superparamagnetism and spin glass states were not seen. In the absence of an external field, the magnetic moments lie close to the film plane. In addition to this shape anisotropy, there is some uniaxial anisotropy. No magnetic dead layers have been observed. The magnetic moments within the Fe layers vary little with the distance from the interfaces. At the interfaces the Fe moment is reduced and an antiparallel moment is induced on the vanadium atoms. It is observed that ultrathin Fe layers behave in a 2D fashion when isolated by sufficiently thick vanadium layers; however, on thinning the vanadium layers, a magnetic coupling between the Fe layers has been observed. We also studied the superconducting properties of V/Fe sandwiches and superlattices. In both cases, the Fe layer, a strong pair-breaker, suppresses the superconducting transition temperature consistent with the current knowledge of the magnetic proximity effect. For the sandwiches with thin (thick) vanadium layers, the temperature dependence of the upper critical fields is consistent with the simple theory for a 2D (3D) superconductor. For the superlattices, when the vanadium layer is on the order of the BCS coherence length and the Fe layer is only a few atomic planes thick, a 2D-3D crossover has been observed in the temperature dependence of the parallel upper critical field. This implies the coexistence of superconductivity and ferromagnetism. We observe three dimensional behavior for thinner Fe layers ((TURN)1 atomic plane) and two dimensional behavior for thicker Fe layers (greater than 10 atomic planes).
Interface structure in nanoscale multilayers near continuous-to-discontinuous regime
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pradhan, P. C.; Majhi, A.; Nayak, M., E-mail: mnayak@rrcat.gov.in
2016-07-28
Interfacial atomic diffusion, reaction, and formation of microstructure in nanoscale level are investigated in W/B{sub 4}C multilayer (ML) system as functions of thickness in ultrathin limit. Hard x-ray reflectivity (XRR) and x-ray diffuse scattering in conjunction with x-ray absorption near edge spectroscopy (XANES) in soft x-ray and hard x-ray regimes and depth profiling x-ray photoelectron spectroscopy (XPS) have been used to precisely evaluate detailed interfacial structure by systematically varying the individual layer thickness from continuous-to-discontinuous regime. It is observed that the interfacial morphology undergoes an unexpected significant modification as the layer thickness varies from continuous-to-discontinuous regime. The interfacial atomic diffusionmore » increases, the physical density of W layer decreases and that of B{sub 4}C layer increases, and further more interestingly the in-plane correlation length decreases substantially as the layer thickness varies from continuous-to-discontinuous regime. This is corroborated using combined XRR and x-ray diffused scattering analysis. XANES and XPS results show formation of more and more tungsten compounds at the interfaces as the layer thickness decreases below the percolation threshold due to increase in the contact area between the elements. The formation of compound enhances to minimize certain degree of disorder at the interfaces in the discontinuous region that enables to maintain the periodic structure in ML. The degree of interfacial atomic diffusion, interlayer interaction, and microstructure is correlated as a function of layer thickness during early stage of film growth.« less
Dawson, Dana K.; Maceira, Alicia M.; Raj, Vimal J.; Graham, Catriona; Pennell, Dudley J.; Kilner, Philip J.
2011-01-01
Background We used cardiovascular magnetic resonance (CMR) to study normal left ventricular (LV) trabeculation as a basis for differentiation from pathological noncompaction. Methods and Results The apparent end-diastolic (ED) and end-systolic (ES) thicknesses and thickening of trabeculated and compacted myocardial layers were measured in 120 volunteers using a consistent selection of basal, mid, and apical CMR short-axis slices. All had a visible trabeculated layer in 1 or more segments. The compacted but not the trabeculated layer was thicker in men than in women (P<0.01 at ED and ES). When plotted against age, the trabeculated and compacted layer thicknesses demonstrated opposite changes: an increase of the compact layer after the fourth decade at both ED and ES (P<0.05) but a decrease of the trabeculated layer. There was age-related preservation of total wall thickness at ED but an increase at ES (P<0.05). The compacted layer thickened, whereas the trabeculated layer thinned with systole, but neither change differed between sexes. With age, the most trabeculated LV segments showed significantly greater systolic thinning of trabeculated layers and, conversely, greater thickening of the compact segments (P<0.05). Total wall thickening is neither sex nor age dependent. There were no sex differences in the trabeculated/compacted ratio at ES or ED, but the ES trabeculated/compacted ratio was smaller in older (50 to 79 years) versus younger (20 to 49 years) groups (P<0.05). Conclusions We demonstrated age- and sex-related morphometric differences in the apparent trabeculated and compacted layer thicknesses and systolic thinning of the visible trabeculated layer that contrasts with compacted myocardial wall thickening. PMID:21193690
Bamberg, Christian; Dudenhausen, Joachim W; Bujak, Verena; Rodekamp, Elke; Brauer, Martin; Hinkson, Larry; Kalache, Karim; Henrich, Wolfgang
2018-06-01
We undertook a randomized clinical trial to examine the outcome of a single vs. a double layer uterine closure using ultrasound to assess uterine scar thickness. Participating women were allocated to one of three uterotomy suture techniques: continuous single layer unlocked suturing, continuous locked single layer suturing, or double layer suturing. Transvaginal ultrasound of uterine scar thickness was performed 6 weeks and 6 - 24 months after Cesarean delivery. Sonographers were blinded to the closure technique. An "intent-to-treat" and "as treated" ANOVA analysis included 435 patients (n = 149 single layer unlocked suturing, n = 157 single layer locked suturing, and n = 129 double layer suturing). 6 weeks postpartum, the median scar thickness did not differ among the three groups: 10.0 (8.5 - 12.3 mm) single layer unlocked vs. 10.1 (8.2 - 12.7 mm) single layer locked vs. 10.8 (8.1 - 12.8 mm) double layer; (p = 0.84). At the time of the second follow-up, the uterine scar was not significantly (p = 0.06) thicker if the uterus had been closed with a double layer closure 7.3 (5.7 - 9.1 mm), compared to single layer unlocked 6.4 (5.0 - 8.8 mm) or locked suturing techniques 6.8 (5.2 - 8.7 mm). Women who underwent primary or elective Cesarean delivery showed a significantly (p = 0.03, p = 0.02, "as treated") increased median scar thickness after double layer closure vs. single layer unlocked suture. A double layer closure of the hysterotomy is associated with a thicker myometrium scar only in primary or elective Cesarean delivery patients. © Georg Thieme Verlag KG Stuttgart · New York.
Farzadi, Arghavan; Solati-Hashjin, Mehran; Asadi-Eydivand, Mitra; Abu Osman, Noor Azuan
2014-01-01
Powder-based inkjet 3D printing method is one of the most attractive solid free form techniques. It involves a sequential layering process through which 3D porous scaffolds can be directly produced from computer-generated models. 3D printed products' quality are controlled by the optimal build parameters. In this study, Calcium Sulfate based powders were used for porous scaffolds fabrication. The printed scaffolds of 0.8 mm pore size, with different layer thickness and printing orientation, were subjected to the depowdering step. The effects of four layer thicknesses and printing orientations, (parallel to X, Y and Z), on the physical and mechanical properties of printed scaffolds were investigated. It was observed that the compressive strength, toughness and Young's modulus of samples with 0.1125 and 0.125 mm layer thickness were more than others. Furthermore, the results of SEM and μCT analyses showed that samples with 0.1125 mm layer thickness printed in X direction have more dimensional accuracy and significantly close to CAD software based designs with predefined pore size, porosity and pore interconnectivity. PMID:25233468
Tunable Transport Gap in Phosphorene
DOE Office of Scientific and Technical Information (OSTI.GOV)
Das, Saptarshi; Zhang, Wei; Demarteau, Marcel
2014-08-11
In this paper, we experimentally demonstrate that the transport gap of phosphorene can be tuned monotonically from ~0.3 to ~1.0 eV when the flake thickness is scaled down from bulk to a single layer. As a consequence, the ON current, the OFF current, and the current ON/OFF ratios of phosphorene field effect transistors (FETs) were found to be significantly impacted by the layer thickness. The transport gap was determined from the transfer characteristics of phosphorene FETs using a robust technique that has not been reported before. The detailed mathematical model is also provided. By scaling the thickness of the gatemore » oxide, we were also able to demonstrate enhanced ambipolar conduction in monolayer and few layer phosphorene FETs. The asymmetry of the electron and the hole current was found to be dependent on the layer thickness that can be explained by dynamic changes of the metal Fermi level with the energy band of phosphorene depending on the layer number. We also extracted the Schottky barrier heights for both the electron and the hole injection as a function of the layer thickness. In conclusion, we discuss the dependence of field effect hole mobility of phosphorene on temperature and carrier concentration.« less
NASA Astrophysics Data System (ADS)
Wang, Shuping; Shibahara, Nanae; Kuramashi, Daishi; Okawa, Shinpei; Kakuta, Naoto; Okada, Eiji; Maki, Atsushi; Yamada, Yukio
2010-07-01
In order to investigate the effects of anatomical variation in human heads on the optical mapping of brain activity, we perform simulations of optical mapping by solving the photon diffusion equation for layered-models simulating human heads using the finite element method (FEM). Particularly, the effects of the spatial variations in the thicknesses of the skull and cerebrospinal fluid (CSF) layers on mapping images are investigated. Mapping images of single active regions in the gray matter layer are affected by the spatial variations in the skull and CSF layer thicknesses, although the effects are smaller than those of the positions of the active region relative to the data points. The increase in the skull thickness decreases the sensitivity of the images to active regions, while the increase in the CSF layer thickness increases the sensitivity in general. The images of multiple active regions are also influenced by their positions relative to the data points and by their depths from the skin surface.
Influence of bulk turbulence and entrance boundary layer thickness on the curved duct flow field
NASA Technical Reports Server (NTRS)
Crawford, R. A.
1988-01-01
The influence of bulk turbulence and boundary layer thickness on the secondary flow development in a square, 90 degree turning duct was investigated. A three-dimensional laser velocimetry system was utilized to measure the mean and fluctuating components of velocity at six cross-planes in the duct. The results from this investigation, with entrance boundary layer thickness of 20 percent, were compared with the thin boundary layer results documented in NASA CR-174811. The axial velocity profiles, cross-flow velocities, and turbulence intensities were compared and evaluated with regard to the influence of bulk turbulence intensity and boundary layer thickness, and the influence was significant. The results of this investigation expand the 90 degree curved duct experimental data base to higher turbulence levels and thicker entrance boundary layers. The experimental results provide a challenging benchmark data base for computational fluid dynamics code development and validation. The variation of inlet bulk turbulence intensity provides additional information to aid in turbulence model evaluation.
Boundary layer thermal stresses in angle-ply composite laminates, part 1. [graphite-epoxy composites
NASA Technical Reports Server (NTRS)
Wang, S. S.; Choi, I.
1981-01-01
Thermal boundary-layer stresses (near free edges) and displacements were determined by a an eigenfunction expansion technique and the establishment of an appropriate particular solution. Current solutions in the region away from the singular domain (free edge) are found to be excellent agreement with existing approximate numerical results. As the edge is approached, the singular term controls the near field behavior of the boundary layer. Results are presented for cases of various angle-ply graphite/epoxy laminates with (theta/-theta/theta/theta) configurations. These results show high interlaminar (through-the-thickness) stresses. Thermal boundary-layer thicknesses of different composite systems are determined by examining the strain energy density distribution in composites. It is shown that the boundary-layer thickness depends on the degree of anisotropy of each individual lamina, thermomechanical properties of each ply, and the relative thickness of adjacent layers. The interlaminar thermal stresses are compressive with increasing temperature. The corresponding residual stresses are tensile and may enhance interply delaminations.
A Thermoelectric Generator Using Porous Si Thermal Isolation
Hourdakis, Emmanouel; Nassiopoulou, Androula G.
2013-01-01
In this paper we report on a thermoelectric generator (TEG) using thermal isolation provided by a thick porous Si layer locally formed on the Si wafer and thermocouples composed of p-doped polycrystalline Si/Al. The “hot” contacts of the thermocouples lie on the porous Si layer, while the “cold” contacts lie on bulk crystalline Si. A housing was also designed and fabricated in order to transfer any external temperature change on the “hot” contacts of the thermocouples, the “cold” contacts being isolated from the “hot” contacts by a thick resist layer. The fabrication of the sensing element (Si die) is fully compatible with batch Si processing. The output power of the thermoelectric generator depends on the porous Si isolation layer thickness, porosity, structure and morphology. For a mesoporous Si layer of 60% porosity and a macroscopic temperature differential of 10 K, an output power of 0.39 μW/cm2 was measured for a 50 μm thick porous Si layer. PMID:24152923
NASA Astrophysics Data System (ADS)
Cheng, Junfeng; Chen, Zhiru; Zhou, Jiaqi; Cao, Zheng; Wu, Dun; Liu, Chunlin; Pu, Hongting
2018-05-01
The effects of layer thickness on the compatibility between polycarbonate (PC) and polystyrene (PS) and physical properties of PC/PS multilayered film via nanolayer coextrusion are studied. The morphology of multilayered structure is observed using a scanning electron microscope. This multilayered structure may have a negative impact on the transparency, but it can improve the water resistance and heat resistance of film. To characterize the compatibility between PC and PS, differential scanning calorimetry is used to measure the glass transition temperature. The compatibility is found to be improved with the decrease of layer thickness. Therefore, the viscosity of multilayered film is also reduced with the decrease of layer thickness. In addition, the multilayered structure can improve the tensile strength with the increase of layer numbers. Because of the complete and continuous layer structure of PC, the PC/PS multilayered film can retain its mechanical strength at the temperature above Tg of PS.
Doped bottom-contact organic field-effect transistors
NASA Astrophysics Data System (ADS)
Liu, Shiyi; Billig, Paul; Al-Shadeedi, Akram; Kaphle, Vikash; Lüssem, Björn
2018-07-01
The influence of doping on doped bottom-gate bottom-contact organic field-effect transistors (OFETs) is discussed. It is shown that the inclusion of a doped layer at the dielectric/organic semiconductor layer leads to a significant reduction in the contact resistances and a fine control of the threshold voltage. Through varying the thickness of the doped layer, a linear shift of threshold voltage V T from ‑3.1 to ‑0.22 V is observed for increasing thickness of doped layer. Meanwhile, the contact resistance at the source and drain electrode is reduced from 138.8 MΩ at V GS = ‑10 V for 3 nm to 0.3 MΩ for 7 nm thick doped layers. Furthermore, an increase of charge mobility is observed for increasing thickness of doped layer. Overall, it is shown that doping can minimize injection barriers in bottom-contact OFETs with channel lengths in the micro-meter regime, which has the potential to increase the performance of this technology further.
Laminate armor and related methods
Chu, Henry S; Lillo, Thomas M; Zagula, Thomas M
2013-02-26
Laminate armor and methods of manufacturing laminate armor. Specifically, laminate armor plates comprising a commercially pure titanium layer and a titanium alloy layer bonded to the commercially pure titanium outer layer are disclosed, wherein an average thickness of the titanium alloy inner layer is about four times an average thickness of the commercially pure titanium outer layer. In use, the titanium alloy layer is positioned facing an area to be protected. Additionally, roll-bonding methods for manufacturing laminate armor plates are disclosed.
Juliano, Pablo; Temmel, Sandra; Rout, Manoj; Swiergon, Piotr; Mawson, Raymond; Knoerzer, Kai
2013-01-01
Recent research has shown that high frequency ultrasound (0.4-3 MHz), can enhance milkfat separation in small scale systems able to treat only a few milliliters of sample. In this work, the effect of ultrasonic standing waves on milkfat creaming was studied in a 6L reactor and the influence of different frequencies and transducer configurations in direct contact with the fluid was investigated. A recombined coarse milk emulsion with fat globules stained with oil-red-O dye was selected for the separation trials. Runs were performed with one or two transducers placed in vertical (parallel or perpendicular) and horizontal positions (at the reactor base) at 0.4, 1 and/or 2 MHz (specific energy 8.5 ± 0.6 kJ/kg per transducer). Creaming behavior was assessed by measuring the thickness of the separated cream layer. Other methods supporting this assessment included the measurement of fat content, backscattering, particle size distribution, and microscopy of samples taken at the bottom and top of the reactor. Most efficient creaming was found after treatment at 0.4 MHz in single and double vertical transducer configurations. Among these configurations, a higher separation rate was obtained when sonicating at 0.4 MHz in a vertical perpendicular double transducer setup. The horizontal transducer configuration promoted creaming at 2 MHz only. Fat globule size increase was observed when creaming occurred. This research highlights the potential for enhanced separation of milkfat in larger scale systems from selected transducer configurations in contact with a dairy emulsion, or emulsion splitting in general. Copyright © 2012 Elsevier B.V. All rights reserved.
An, Jae Seok; Jang, Ha Jun; Park, Cheol Young; Youn, Hongseok; Lee, Jong Ho; Heo, Gi-Seok; Choi, Bum Ho; Lee, Choong Hun
2015-10-01
Inorganic/organic hybrid thin film encapsulation layers consist of a thin Al2O3 layer together with polymer material. We have investigated optical properties of thin film encapsulation layers for top-emission flexible organic light-emitting diodes. The transmittance of hybrid thin film encapsulation layers and the electroluminescent spectrum of organic light-emitting diodes that were passivated by hybrid organic/inorganic thin film encapsulation layers were also examined as a function of the thickness of inorganic Al203 and monomer layers. The number of interference peaks, their intensity, and their positions in the visible range can be controlled by varying the thickness of inorganic Al2O3 layer. On the other hand, changing the thickness of monomer layer had a negligible effect on the optical properties. We also verified that there is a trade-off between transparency in the visible range and the permeation of water vapor in hybrid thin film encapsulation layers. As the number of dyads decreased, optical transparency improved while the water vapor permeation barrier was degraded. Our study suggests that, in top-emission organic light-emitting diodes, the thickness of each thin film encapsulation layer, in particular that of the inorganic layer, and the number of dyads should be controlled for highly efficient top-emission flexible organic light-emitting diodes.
Streit, L; Dražan, L; Schneiderová, M; Kubek, T; Sin, P; Veselý, K; Coufal, O; Veselý, J
2017-01-01
The latissimus dorsi flap is a reliable and one of the most commonly used methods of both immediate and delayed breast reconstruction. Its disadvantage is the limited volume of transferred tissue. The authors present their experience with the use of extended latissimus dorsi flap associated with immediate fat grafting into the pectoralis and latissimus dorsi muscles for secondary breast reconstruction. From 2013 to 2016, 14 patients underwent secondary unilateral total breast reconstruction with extended latissimus dorsi flap associated with primary fat grafting into the pectoralis major and latissimus dorsi muscles. Fat was injected under visual control between muscle fibers. Fat injected into the pectoralis muscle formed an apparent bulging - autoprosthesis. Mean patient age was 48.2 years (range, 34 to 64 years). Mean injected fat volume was 86.4 ml (range, 50 to 160 ml) and majority of this volume was injected into the pectoralis muscle. All flaps healed uneventfully and no fat grafting-related complications were observed. The most common complication was donor site seroma, which occurred in 57.1%. Results of postoperative ultrasound examination were evaluated. Incidence and the size of oil cysts and fat necroses were significantly lower in muscular layer in comparison with the subcutaneous layer of the reconstructed breast. Immediate fat transfer into the pectoralis and latissimus dorsi muscle increases the breast volume during the reconstruction with extended latissimus dorsi flap avoiding implant-related complications when abdominal tissue is not available. Pectoralis and latissimus dorsi muscles were shown as reliable and safe recipients for fat grafting.
Shah, Syaiful Redzwan Mohd; Velander, Jacob; Mathur, Parul; Perez, Mauricio D; Asan, Noor Badariah; Kurup, Dhanesh G; Blokhuis, Taco J; Augustine, Robin
2018-02-21
In recent research, microwave sensors have been used to follow up the recovery of lower extremity trauma patients. This is done mainly by monitoring the changes of dielectric properties of lower limb tissues such as skin, fat, muscle, and bone. As part of the characterization of the microwave sensor, it is crucial to assess the signal penetration in in vivo tissues. This work presents a new approach for investigating the penetration depth of planar microwave sensors based on the Split-Ring Resonator in the in vivo context of the femoral area. This approach is based on the optimization of a 3D simulation model using the platform of CST Microwave Studio and consisting of a sensor of the considered type and a multilayered material representing the femoral area. The geometry of the layered material is built based on information from ultrasound images and includes mainly the thicknesses of skin, fat, and muscle tissues. The optimization target is the measured S 11 parameters at the sensor connector and the fitting parameters are the permittivity of each layer of the material. Four positions in the femoral area (two at distal and two at thigh) in four volunteers are considered for the in vivo study. The penetration depths are finally calculated with the help of the electric field distribution in simulations of the optimized model for each one of the 16 considered positions. The numerical results show that positions at the thigh contribute the highest penetration values of up to 17.5 mm. This finding has a high significance in planning in vitro penetration depth measurements and other tests that are going to be performed in the future.
Microstructure and thermochromic properties of VOX-WOX-VOX ceramic thin films
NASA Astrophysics Data System (ADS)
Khamseh, S.; Araghi, H.; Ghahari, M.; Faghihi Sani, M. A.
2016-03-01
W-doped VO2 films have been synthesized via oxygen annealing of V-W-V (vanadium-tungsten-vanadium) multilayered films. The effects of middle layer's thickness of V-W-V multilayered film on structure and properties of VOX-WOX-VOX ceramic thin films were investigated. The as-deposited V-W-V multilayered film showed amorphous-like structure when mixed structure of VO2 (M) and VO2 (B) was formed in VOX-WOX-VOX ceramic thin films. Tungsten content of VOX-WOX-VOX ceramic thin films increased with increasing middle layer's thickness. With increasing middle layer's thickness, room temperature square resistance ( R sq) of VOX-WOX-VOX ceramic thin films increased from 65 to 86 kΩ/sq. The VOX-WOX-VOX ceramic thin film with the thinnest middle layer showed significant SMT (semiconductor-metal transition) when SMT became negligible on increasing middle layer's thickness.
Li, Y Z; Wang, Z L; Luo, H; Wang, Y Z; Xu, W J; Ran, G Z; Qin, G G; Zhao, W Q; Liu, H
2010-07-19
A phosphorescent organic light-emitting diode (PhOLED) with a nanometer-thick (approximately 10 nm) Ni silicide/ polycrystalline p-Si composite anode is reported. The structure of the PhOLED is Al mirror/ glass substrate / Si isolation layer / Ni silicide / polycrystalline p-Si/ V(2)O(5)/ NPB/ CBP: (ppy)(2)Ir(acac)/ Bphen/ Bphen: Cs(2)CO(3)/ Sm/ Au/ BCP. In the composite anode, the Ni-induced polycrystalline p-Si layer injects holes into the V(2)O(5)/ NPB, and the Ni silicide layer reduces the sheet resistance of the composite anode and thus the series resistance of the PhOLED. By adopting various measures for specially optimizing the thickness of the Ni layer, which induces Si crystallization and forms a Ni silicide layer of appropriate thickness, the highest external quantum efficiency and power conversion efficiency have been raised to 26% and 11%, respectively.
Oxygen octahedral distortions in LaMO 3/SrTiO 3 superlattices
Sanchez-Santolino, Gabriel; Cabero, Mariona; Varela, Maria; ...
2014-04-24
Here we study the interfaces between the Mott insulator LaMnO 3 (LMO) and the band insulator SrTiO 3 (STO) in epitaxially grown superlattices with different thickness ratios and different transport and magnetic behaviors. Using atomic resolution electron energy-loss spectrum imaging, we analyze simultaneously the structural and chemical properties of these interfaces. We find changes in the oxygen octahedral tilts within the LaMnO 3 layers when the thickness ratio between the manganite and the titanate layers is varied. Superlattices with thick LMO and ultrathin STO layers present unexpected octahedral tilts in the STO, along with a small amount of oxygen vacancies.more » On the other hand, thick STO layers exhibit undistorted octahedra while the LMO layers present reduced O octahedral distortions near the interfaces. In conclusion, these findings will be discussed in view of the transport and magnetic differences found in previous studies.« less
Antiferromagnetic exchange and magnetoresistance enhancement in Co-Re superlattices
NASA Astrophysics Data System (ADS)
Freitas, P. P.; Melo, L. V.; Trindade, I.; From, M.; Ferreira, J.; Monteiro, P.
1992-02-01
Co-Re superlattices were prepared that show either antiferromagnetic or ferromagnetic coupling between the Co layers depending on the Re spacer thickness. Enhanced saturation magnetoresistance occurs for antiferromagnetically coupled layers. The saturation magnetoresistance decays exponentially with Re thickness but does not depend critically on the Co thickness.
Low-level laser therapy for fat layer reduction: a comprehensive review.
Avci, Pinar; Nyame, Theodore T; Gupta, Gaurav K; Sadasivam, Magesh; Hamblin, Michael R
2013-08-01
Low-level laser (light) therapy (LLLT) is a noninvasive, nonthermal approach to disorders requiring reduction of pain and inflammation and stimulation of healing and tissue regeneration. Within the last decade, LLLT started being investigated as an adjuvant to liposuction, for noninvasive body contouring, reduction of cellulite, and improvement of blood lipid profile. LLLT may also aid autologous fat transfer procedures by enhancing the viability of adipocytes. However the underlying mechanism of actions for such effects still seems to be unclear. It is important, therefore, to understand the potential efficacy and proposed mechanism of actions of this new procedure for fat reduction. A review of the literature associated with applications of LLLT related to fat layer reduction was performed to evaluate the findings from pre-clinical and clinical studies with respect to the mechanism of action, efficacy, and safety. The studies as of today suggest that LLLT has a potential to be used in fat and cellulite reduction as well as in improvement of blood lipid profile without any significant side effects. One of the main proposed mechanism of actions is based upon production of transient pores in adipocytes, allowing lipids to leak out. Another is through activation of the complement cascade which could cause induction of adipocyte apoptosis and subsequent release of lipids. Although the present studies have demonstrated safety and efficacy of LLLT in fat layer reduction, studies demonstrating the efficacy of LLLT as a stand-alone procedure are still inadequate. Moreover, further studies are necessary to identify the mechanism of action. Copyright © 2013 Wiley Periodicals, Inc.
Low-Level Laser Therapy for Fat Layer Reduction: A Comprehensive Review
Avci, Pinar; Nyame, Theodore T.; Gupta, Gaurav K.; Sadasivam, Magesh; Hamblin, Michael R.
2013-01-01
Background and Objective Low-level laser (light) therapy (LLLT) is a noninvasive, nonthermal approach to disorders requiring reduction of pain and inflammation and stimulation of healing and tissue regeneration. Within the last decade, LLLT started being investigated as an adjuvant to liposuction, for noninvasive body contouring, reduction of cellulite, and improvement of blood lipid profile. LLLT may also aid autologous fat transfer procedures by enhancing the viability of adipocytes. However the underlying mechanism of actions for such effects still seems to be unclear. It is important, therefore, to understand the potential efficacy and proposed mechanism of actions of this new procedure for fat reduction. Materials and Methods A review of the literature associated with applications of LLLT related to fat layer reduction was performed to evaluate the findings from pre-clinical and clinical studies with respect to the mechanism of action, efficacy, and safety. Results The studies as of today suggest that LLLT has a potential to be used in fat and cellulite reduction as well as in improvement of blood lipid profile without any significant side effects. One of the main proposed mechanism of actions is based upon production of transient pores in adipocytes, allowing lipids to leak out. Another is through activation of the complement cascade which could cause induction of adipocyte apoptosis and subsequent release of lipids. Conclusion Although the present studies have demonstrated safety and efficacy of LLLT in fat layer reduction, studies demonstrating the efficacy of LLLT as a stand-alone procedure are still inadequate. Moreover, further studies are necessary to identify the mechanism of action. PMID:23749426
Methods To Determine the Silicone Oil Layer Thickness in Sprayed-On Siliconized Syringes.
Loosli, Viviane; Germershaus, Oliver; Steinberg, Henrik; Dreher, Sascha; Grauschopf, Ulla; Funke, Stefanie
2018-01-01
The silicone lubricant layer in prefilled syringes has been investigated with regards to siliconization process performance, prefilled syringe functionality, and drug product attributes, such as subvisible particle levels, in several studies in the past. However, adequate methods to characterize the silicone oil layer thickness and distribution are limited, and systematic evaluation is missing. In this study, white light interferometry was evaluated to close this gap in method understanding. White light interferometry demonstrated a good accuracy of 93-99% for MgF 2 coated, curved standards covering a thickness range of 115-473 nm. Thickness measurements for sprayed-on siliconized prefilled syringes with different representative silicone oil distribution patterns (homogeneous, pronounced siliconization at flange or needle side, respectively) showed high instrument (0.5%) and analyst precision (4.1%). Different white light interferometry instrument parameters (autofocus, protective shield, syringe barrel dimensions input, type of non-siliconized syringe used as base reference) had no significant impact on the measured average layer thickness. The obtained values from white light interferometry applying a fully developed method (12 radial lines, 50 mm measurement distance, 50 measurements points) were in agreement with orthogonal results from combined white and laser interferometry and 3D-laser scanning microscopy. The investigated syringe batches (lot A and B) exhibited comparable longitudinal silicone oil layer thicknesses ranging from 170-190 nm to 90-100 nm from flange to tip and homogeneously distributed silicone layers over the syringe barrel circumference (110- 135 nm). Empty break-loose (4-4.5 N) and gliding forces (2-2.5 N) were comparably low for both analyzed syringe lots. A silicone oil layer thickness of 100-200 nm was thus sufficient for adequate functionality in this particular study. Filling the syringe with a surrogate solution including short-term exposure and emptying did not significantly influence the silicone oil layer at the investigated silicone level. It thus appears reasonable to use this approach to characterize silicone oil layers in filled syringes over time. The developed method characterizes non-destructively the layer thickness and distribution of silicone oil in empty syringes and provides fast access to reliable results. The gained information can be further used to support optimization of siliconization processes and increase the understanding of syringe functionality. LAY ABSTRACT: Silicone oil layers as lubricant are required to ensure functionality of prefilled syringes. Methods evaluating these layers are limited, and systematic evaluation is missing. The aim of this study was to develop and assess white light interferometry as an analytical method to characterize sprayed-on silicone oil layers in 1 mL prefilled syringes. White light interferometry showed a good accuracy (93-99%) as well as instrument and analyst precision (0.5% and 4.1%, respectively). Different applied instrument parameters had no significant impact on the measured layer thickness. The obtained values from white light interferometry applying a fully developed method concurred with orthogonal results from 3D-laser scanning microscopy and combined white light and laser interferometry. The average layer thicknesses in two investigated syringe lots gradually decreased from 170-190 nm at the flange to 100-90 nm at the needle side. The silicone layers were homogeneously distributed over the syringe barrel circumference (110-135 nm) for both lots. Empty break-loose (4-4.5 N) and gliding forces (2-2.5 N) were comparably low for both analyzed syringe lots. Syringe filling with a surrogate solution, including short-term exposure and emptying, did not significantly affect the silicone oil layer. The developed, non-destructive method provided reliable results to characterize the silicone oil layer thickness and distribution in empty siliconized syringes. This information can be further used to support optimization of siliconization processes and increase understanding of syringe functionality. © PDA, Inc. 2018.
Revisions of rump fat and body scoring indices for deer, elk, and moose
Cook, Rachel C.; Cook, John G.; Stephenson, Thomas R.; Myers, Woodrow L.; Mccorquodale, Scott M.; Vales, David J.; Irwin, Larry L.; Hall, P. Briggs; Spencer, Rocky D.; Murphie, Shannon L.; Schoenecker, Kathryn A.; Miller, Patrick J.
2010-01-01
Because they do not require sacrificing animals, body condition scores (BCS), thickness of rump fat (MAXFAT), and other similar predictors of body fat have advanced estimating nutritional condition of ungulates and their use has proliferated in North America in the last decade. However, initial testing of these predictors was too limited to assess their reliability among diverse habitats, ecotypes, subspecies, and populations across the continent. With data collected from mule deer (Odocoileus hemionus), elk (Cervus elaphus), and moose (Alces alces) during initial model development and data collected subsequently from free-ranging mule deer and elk herds across much of the western United States, we evaluated reliability across a broader range of conditions than were initially available. First, to more rigorously test reliability of the MAXFAT index, we evaluated its robustness across the 3 species, using an allometric scaling function to adjust for differences in animal size. We then evaluated MAXFAT, rump body condition score (rBCS), rLIVINDEX (an arithmetic combination of MAXFAT and rBCS), and our new allometrically scaled rump-fat thickness index using data from 815 free-ranging female Roosevelt and Rocky Mountain elk (C. e. roosevelti and C. e. nelsoni) from 19 populations encompassing 4 geographic regions and 250 free-ranging female mule deer from 7 populations and 2 regions. We tested for effects of subspecies, geographic region, and captive versus free-ranging existence. Rump-fat thickness, when scaled allometrically with body mass, was related to ingesta-free body fat over a 38–522-kg range of body mass (r2 = 0.87; P < 0.001), indicating the technique is remarkably robust among at least the 3 cervid species of our analysis. However, we found an underscoring bias with the rBCS for elk that had >12% body fat. This bias translated into a difference between subspecies, because Rocky Mountain elk tended to be fatter than Roosevelt elk in our sample. Effects of observer error with the rBCS also existed for mule deer with moderate to high levels of body fat, and deer body size significantly affected accuracy of the MAXFAT predictor. Our analyses confirm robustness of the rump-fat index for these 3 species but highlight the potential for bias due to differences in body size and to observer error with BCS scoring. We present alternative LIVINDEX equations where potential bias from rBCS and bias due to body size are eliminated or reduced. These modifications improve the accuracy of estimating body fat for projects intended to monitor nutritional status of herds or to evaluate nutrition's influence on population demographics.
Kim, Min Su; Kim, Do Yeob; Kim, Sung-O; Leem, Jae-Young
2013-05-01
ZnO nanorods were grown on the Mg0.2Zn0.8O seed layers with different thickness by hydrothermal method. Scanning electron microscopy (SEM), X-ray diffraction (XRD), and photoluminescence (PL) were carried out to investigate the effects of the Mg0.2Zn0.8O seed layer thickness on the structural and the optical properties of the ZnO nanorods. The residual stress in the Mg0.2Zn0.8O seed layers was depended on the thickness while the texture coefficient of the Mg0.2Zn0.8O seed layers was not affected significantly. The smaller full width at half maximum (FWHM) of the ZnO (002) diffraction and near-band-edge emission (NBE) peak and the larger average grain size were observed from the ZnO nanorods grown on the Mg0.2Zn0.8O seed layers with 5 layers (thickness of 350 nm), which indicate the enhancement the structural and the optical properties of the ZnO nanorods.
NASA Astrophysics Data System (ADS)
Scott, Ethan A.; Gaskins, John T.; King, Sean W.; Hopkins, Patrick E.
2018-05-01
The need for increased control of layer thickness and uniformity as device dimensions shrink has spurred increased use of atomic layer deposition (ALD) for thin film growth. The ability to deposit high dielectric constant (high-k) films via ALD has allowed for their widespread use in a swath of optical, optoelectronic, and electronic devices, including integration into CMOS compatible platforms. As the thickness of these dielectric layers is reduced, the interfacial thermal resistance can dictate the overall thermal resistance of the material stack compared to the resistance due to the finite dielectric layer thickness. Time domain thermoreflectance is used to interrogate both the thermal conductivity and the thermal boundary resistance of aluminum oxide, hafnium oxide, and titanium oxide films on silicon. We calculate a representative design map of effective thermal resistances, including those of the dielectric layers and boundary resistances, as a function of dielectric layer thickness, which will be of great importance in predicting the thermal resistances of current and future devices.
NASA Technical Reports Server (NTRS)
Deshpande, Manohar D.; Dudley, Kenneth
2003-01-01
A simple method is presented to estimate the complex dielectric constants of individual layers of a multilayer composite material. Using the MatLab Optimization Tools simple MatLab scripts are written to search for electric properties of individual layers so as to match the measured and calculated S-parameters. A single layer composite material formed by using materials such as Bakelite, Nomex Felt, Fiber Glass, Woven Composite B and G, Nano Material #0, Cork, Garlock, of different thicknesses are tested using the present approach. Assuming the thicknesses of samples unknown, the present approach is shown to work well in estimating the dielectric constants and the thicknesses. A number of two layer composite materials formed by various combinations of above individual materials are tested using the present approach. However, the present approach could not provide estimate values close to their true values when the thicknesses of individual layers were assumed to be unknown. This is attributed to the difficulty in modelling the presence of airgaps between the layers while doing the measurement of S-parameters. A few examples of three layer composites are also presented.
Meservey, C M; Carey, G B
1994-12-01
This study examined the effects of dietary fat saturation and endurance exercise on lipolytic sensitivity of adipocytes isolated from Yucatan miniature swine. Twenty-four female swine had free access to a high fat diet with a polyunsaturated to saturated fat ratio (P:S) of 0.3 or 1.0, and were treadmill-exercised or remained sedentary. After 3 months, biopsies were taken, adipocytes were isolated and lipolytic activity was determined. Adipocytes were incubated with adenosine deaminase followed by epinephrine, isoproterenol, or epinephrine plus phenylisopropyladenosine, and glycerol release was measured. Backfat thickness was measured by ultrasonography. Our findings revealed that 1) adipocytes from 1.0 P:S diet-fed swine released 30% more glycerol than adipocytes from 0.3 P:S diet-fed swine when stimulated by 1 micromol/L isoproterenol; 2) adipocytes from exercised swine released 45% more glycerol than adipocytes from sedentary swine when stimulated by 1 micromol/L epinephrine; 3) body weight of exercised swine was significantly lower than sedentary swine; and 4) backfat thickness was less in exercised swine than in sedentary swine (2.39 vs. 2.95 cm, P = 0.002). We conclude that ad libitum consumption of diet with a P:S of 1.0, combined with endurance exercise, increases lipolytic sensitivity, lowers body weight gain, and reduces fat accumulation in female Yucatan miniature swine.
An anthropometric model to estimate neonatal fat mass using air displacement plethysmography
2012-01-01
Background Current validated neonatal body composition methods are limited/impractical for use outside of a clinical setting because they are labor intensive, time consuming, and require expensive equipment. The purpose of this study was to develop an anthropometric model to estimate neonatal fat mass (kg) using an air displacement plethysmography (PEA POD® Infant Body Composition System) as the criterion. Methods A total of 128 healthy term infants, 60 females and 68 males, from a multiethnic cohort were included in the analyses. Gender, race/ethnicity, gestational age, age (in days), anthropometric measurements of weight, length, abdominal circumference, skin-fold thicknesses (triceps, biceps, sub scapular, and thigh), and body composition by PEA POD® were collected within 1-3 days of birth. Backward stepwise linear regression was used to determine the model that best predicted neonatal fat mass. Results The statistical model that best predicted neonatal fat mass (kg) was: -0.012 -0.064*gender + 0.024*day of measurement post-delivery -0.150*weight (kg) + 0.055*weight (kg)2 + 0.046*ethnicity + 0.020*sum of three skin-fold thicknesses (triceps, sub scapular, and thigh); R2 = 0.81, MSE = 0.08 kg. Conclusions Our anthropometric model explained 81% of the variance in neonatal fat mass. Future studies with a greater variety of neonatal anthropometric measurements may provide equations that explain more of the variance. PMID:22436534
Interfacial thin films rupture and self-similarity
NASA Astrophysics Data System (ADS)
Ward, Margaret H.
2011-06-01
Two superposed thin layers of fluids are prone to interfacial instabilities due to London-van der Waals forces. Evolution equations for the film thicknesses are derived using lubrication theory. Using the intrinsic scales, for a single layer, results in a system with parametric dependence of four ratios of the two layers: surface tension, Hamaker constant, viscosity, and film thickness. In contrast to the single layer case, the bilayer system has two unstable eigenmodes: squeezing and bending. For some particular parameter regimes, the system exhibits the avoided crossing behavior, where the two eigenmodes are interchanged. Based on numerical analysis, the system evolves into four different rupture states: basal layer rupture, upper layer rupture, double layer rupture, and mixed layer rupture. The ratio of Hamaker constants and the relative film thickness of the two layers control the system dynamics. Remarkably, the line of avoided crossing demarks the transition region of mode mixing and energy transfer, affecting the scaling of the dynamical regime map consequentially. Asymptotic and numerical analyses are used to examine the self-similar ruptures and to extract the power law scalings for both the basal layer rupture and the upper layer rupture. The scaling laws for the basal layer rupture are the same as those of the single layer on top of a substrate. The scaling laws for the upper layer rupture are different: the lateral length scale decreases according to (tr-t)1/3 and the film thickness decreases according to (tr-t)1/6.
Article and method for making an article
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lacy, Benjamin Paul; Schick, David Edward; Kottilingam, Srikanth Chandrudu
An article and a method for making shaped cooling holes in an article are provided. The method includes the steps of providing a metal alloy powder; forming an initial layer with the metal alloy powder, the initial layer having a preselected thickness and a preselected shape, the preselected shape including at least one aperture; sequentially forming an additional layer over the initial layer with the metal alloy powder, the additional layer having a second preselected thickness and a second preselected shape, the second preselected shape including at least one aperture corresponding to the at least one aperture in the initialmore » layer; and joining the additional layer to the initial layer, forming a structure having a predetermined thickness, a predetermined shape, and at least one aperture having a predetermined profile. The structure is attached to a substrate to make the article.« less
Human Chorioretinal Layer Thicknesses Measured in Macula-wide, High-Resolution Histologic Sections
Messinger, Jeffrey D.; Sloan, Kenneth R.; Mitra, Arnab; McGwin, Gerald; Spaide, Richard F.
2011-01-01
Purpose. To provide a comprehensive description of chorioretinal layer thicknesses in the normal human macula, including two-layer pairs that can produce a combined signal in some optical coherence tomography (OCT) devices (ganglion cell [GCL] and inner plexiform [IPL] layers and outer plexiform [OPL] and outer nuclear [ONL] layers). Methods. In 0.8-μm-thick, macula-wide sections through the foveola of 18 donors (age range, 40–92 years), 21 layers were measured at 25 locations by a trained observer and validated by a second observer. Tissue volume changes were assessed by comparing total retinal thickness in ex vivo OCT and in sections. Results. Median tissue shrinkage was 14.5% overall and 29% in the fovea. Histologic laminar boundaries resembled those in SD-OCT scans, but the shapes of the foveolar OPL and ONL differed. Histologic GCL, IPL, and OPLHenle were thickest at 0.8. to 1, 1.5, and 0.4 mm eccentricity, respectively. ONL was thickest in an inward bulge at the foveal center. At 1 mm eccentricity, GCL, INL, and OPLHenle represented 17.3% to 21.1%, 18.0% to 18.5%, and 14.2% to 16.6% of total retinal thickness, respectively. In donors ≥70 years of age, the RPE and choroid were 17.1% and 29.6% thinner and OPLHenle was 20.8% thicker than in donors <70 years. Conclusions. In this study, the first graphic representation and thickness database of chorioretinal layers in normal macula were generated. Newer OCT systems can separate GCL from IPL and OPLHenle from ONL, with good agreement for the proportion of retinal thickness occupied by OPLHenle in OCT and histology. The thickening of OPLHenle in older eyes may reflect Müller cell hypertrophy associated with rod loss. PMID:21421869
Comparison of skeletal muscle mass to fat-free mass ratios among different ethnic groups.
Abe, T; Bemben, M G; Kondo, M; Kawakami, Y; Fukunaga, T
2012-01-01
Asians seem to have less skeletal muscle mass (SMM) than other ethnic groups, but it is not clear whether relative SMM, i.e., SMM / height square or SMM to fat-free mass (FFM) ratio, differs among different ethnic groups at the same level of body mass index (BMI). To compare the SMM to fat-free mass (FFM) ratio as well as anthropometric variables and body composition among 3 ethnic groups. Three hundred thirty-nine Japanese, 343 Brazilian, and 183 German men and women were recruited for this cross-sectional study. Muscle thickness (MTH) and subcutaneous fat thickness (FTH) were measured by ultrasound at nine sites on the anterior and posterior aspects of the body. FTH was used to estimate the body density, from which fat mass and fat-free mass (FFM) was calculated by using Brozek equation. Total SMM was estimated from ultrasound-derived prediction equations. Percentage body fat was similar among the ethnic groups in men, while Brazilians were higher than Japanese in women. In German men and women, absolute SMM and FFM were higher than in their Japanese and Brazilians counterparts. SMM index and SMM:FFM ratios were similar among the ethnic groups in women, excluding SMM:FFM ratio in Brazilian. In men, however, these relative values (SMM index and SMM:FFM ratio) were still higher in Germans. After adjusting for age and BMI, the SMM index and SMM:FFM ratios were lower in Brazilian men and women compared with the other two ethnic groups, while the SMM index and SMM:FFM ratios were similar in Japanese and German men and women, excluding SMM:FFM ratio in women. Our results suggest that relative SMM is not lower in Asian populations compared with European populations after adjusted by age and BMI.
Comparison of the effects of swimming and Tai Chi Chuan on body fat composition in elderly people.
Yu, Tung-Yang; Pei, Yu-Cheng; Lau, Yiu-Chung; Chen, Chih-Kuang; Hsu, Hung-Chih; Wong, Alice M K
2007-01-01
Accumulation of fat and substantial loss of muscle mass are common phenomena in the elderly. In this study, we observed the effects of Tai Chi Chuan (TCC) and swimming, two exercises suitable for elderly people, on the percentage body fat and fat distribution by measuring subcutaneous adipose tissue thickness and body composition. Subjects were divided into three groups: regular swimmers (n = 20), regular TCC practitioners (n = 32), and age-matched control subjects (n = 31). Subcutaneous adipose tissue thickness was taken using a Lange skinfold caliper at the chests, abdomens, and thighs in the men, and the triceps, suprailium, and thighs in the women. Mid-arm circumference (MAC) was measured on the non-dominant upper arm using fiberglass tape. Body composition was analyzed using the Inbody 3.0 logo, a bioelectrical impedance analysis (BIA) system. No significant differences were found between the three test groups in relation to total body adiposity and arm muscle circumference in the men and women. There was significantly less subcutaneous adipose tissue at the abdomen (p = 0.011) and thigh (p < 0.001) of TCC-group men and at the thighs (p < 0.001) of the swimming group compared with the control group. In women, only the thigh skinfold (p = 0.002) showed a decrease in the TCC group compared with the control group. Swimming and TCC may not decrease total fat adiposity in elderly men and women, however, they may change body fat distribution due to certain muscle group usage. The differences observed in the effects of exercise on body fat distribution between elderly women and men may be gender-related.
Kanamori, Akiyasu; Nakamura, Makoto; Matsui, Noriko; Nagai, Azusa; Nakanishi, Yoriko; Kusuhara, Sentaro; Yamada, Yuko; Negi, Akira
2004-12-01
To analyze retinal nerve fiber layer (RNFL) thickness in eyes with band atrophy by use of optical coherence tomography (OCT) and to evaluate the ability of OCT to detect this characteristic pattern of RNFL loss. Cross-sectional, retrospective study. Thirty-four eyes of 18 patients with bitemporal hemianopia caused by optic chiasm compression by chiasmal tumors were studied. All eyes were divided into 3 groups according to visual field loss grading after Goldmann perimetry. Retinal nerve fiber layer thickness measurements with OCT. Retinal nerve fiber layer thickness around the optic disc was measured by OCT (3.4-mm diameter circle). Calculation of the changes in OCT parameters, including the horizontal (nasal + temporal quadrant RNFL thickness) and vertical values (superior + inferior quadrant RNFL thickness) was based on data from 160 normal eyes. Comparison between the 3 visual field grading groups was done with the analysis of variance test. The receiver operating characteristic (ROC) curve for the horizontal and vertical value were calculated, and the areas under the curve (AUC) were compared. Retinal nerve fiber layer thickness in eyes with band atrophy decreased in all OCT parameters. The reduction rate in average and temporal RNFL thickness and horizontal value was correlated with visual field grading. The AUC of horizontal value was 0.970+/-0.011, which was significantly different from AUC of vertical value (0.903+/-0.022). The degree of RNFL thickness reduction correlated with that of visual field defects. Optical coherence tomography was able to identify the characteristic pattern of RNFL loss in these eyes.
Relationship Between Neck Circumference and Epicardial Fat Thickness in a Healthy Male Population.
Küçük, Uğur; Küçük, Hilal Olgun; Cüce, Ferhat; Balta, Sevket
2016-09-01
Epicardial fat is an upper body visceral fat depot that may play a significant role in the development of adverse metabolic and cardiovascular risk profiles. There is a significant direct relationship between the amount of epicardial fat and general body adiposity (body mass index, BMI), but data regarding subcutaneous adiposity is limited. We conducted a study to determine the association between neck circumference and epicardial fat thickness in healthy young male individuals, and assess their individual correlations with general body adiposity and cardiometabolic risk factors. One hundred consecutive male patients aged 18 years or older with no known major medical conditions were included in the study. All participants underwent detailed physical examination including measurement of blood pressure, weight, height, waist/hip ratio, and neck circumference. Blood was collected to determine fasting glucose and lipid parameters. A standard echocardiographic examination was performed with additional epicardial fat thickness determination. Among 100 study participants, neck circumference correlated significantly with weight, waist circumference, BMI, blood glucose, serum total cholesterol, low-density (LDL)-cholesterol, and triglycerides levels. No significant correlation was found between neck circumference and high-density lipoprotein (HDL)-cholesterol levels. Neck circumference correlated moderately and positively with echocardiographic epicardial fat thickness. Among patients with low cardiometabolic risk, increased neck circumference was associated with increased epicardial fat thickness. A gordura epicárdica é um depósito de gordura visceral na parte superior do organismo que pode desempenhar um papel importante no desenvolvimento de perfis cardiovasculares e metabólicos adversos. Há uma relação direta significativa entre a quantidade de gordura epicárdica e a adiposidade corporal geral (índice de massa corporal, IMC), mas dados sobre a adiposidade subcutânea são limitados. Realizamos um estudo para determinar a associação entre a circunferência do pescoço e a espessura da gordura epicárdica em jovens saudáveis do sexo masculino, além de avaliar as suas correlações individuais com a adiposidade corporal geral e fatores de risco cardiometabólicos. Cem pacientes consecutivos do sexo masculino com idade igual ou superior a 18 anos e sem nenhuma condição médica importante e conhecida foram incluídos no estudo. Todos os participantes foram submetidos a um exame físico detalhado que incluiu medida da pressão arterial, peso, altura, razão cintura/quadril e circunferência do pescoço. Sangue foi coletado para determinação da glicemia de jejum e parâmetros lipídicos. Um exame ecocardiográfico padrão foi realizado com determinação adicional da espessura da gordura epicárdica. Entre os 100 participantes do estudo, a circunferência do pescoço mostrou correlação significativa com o peso, circunferência de cintura, IMC, glicemia e níveis séricos de colesterol total, lipoproteína de baixa densidade (LDL-colesterol) e triglicerídeos. Não foi observada correlação significativa entre a circunferência do pescoço e níveis de colesterol de alta densidade (HDL-colesterol). A circunferência do pescoço correlacionou moderadamente e positivamente com a espessura da gordura epicárdica à ecocardiografia. Entre pacientes com baixo risco cardiometabólico, o aumento da circunferência do pescoço foi associado a um aumento da espessura da gordura epicárdica.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matvejeff, M., E-mail: mikko.matvejeff@picosun.com; Department of Chemistry, Aalto University, Kemistintie 1, 02150 Espoo; Ahvenniemi, E.
We study magnetic coupling between hole-doped manganite layers separated by either a perovskite or a rock-salt barrier of variable thickness. Both the type and the quality of the interface have a strong impact on the minimum critical barrier thickness where the manganite layers become magnetically decoupled. A rock-salt barrier layer only 1 unit cell (0.5 nm) thick remains insulating and is able to magnetically de-couple the electrode layers. The technique can therefore be used for developing high-performance planar oxide electronic devices such as magnetic tunnel junctions and quantum well structures that depend on magnetically and electronically sharp heterointerfaces.
Note: Measurement of the cathode layer thickness in glow discharges with a Langmuir probe
NASA Astrophysics Data System (ADS)
Wang, Hao; Hou, Xinyu; Zou, Xiaobing; Luo, Haiyun; Wang, Xinxin
2018-06-01
A method using a Langmuir probe to determine the thickness of the cathode layer for a glow discharge is developed. The method is based on the phenomenon that the curve of the voltage-current characteristics changes in shape as the Langmuir probe moves from the positive column into the cathode layer. The method was used to measure the thicknesses of the cathode layer in the normal glow discharges of argon and air with the cathodes made from stainless steel and aluminum. The results are in good agreement with those given in a book of gas discharge.
Drits, Victor A.; Eberl, Dennis D.; Środoń, Jan
1998-01-01
A modified version of the Bertaut-Warren-Averbach (BWA) technique (Bertaut 1949, 1950; Warren and Averbach 1950) has been developed to measure coherent scattering domain (CSD) sizes and strains in minerals by analysis of X-ray diffraction (XRD) data. This method is used to measure CSD thickness distributions for calculated and experimental XRD patterns of illites and illite-smectites (I-S). The method almost exactly recovers CSD thickness distributions for calculated illite XRD patterns. Natural I-S samples contain swelling layers that lead to nonperiodic structures in the c* direction and to XRD peaks that are broadened and made asymmetric by mixed layering. Therefore, these peaks cannot be analyzed by the BWA method. These difficulties are overcome by K-saturation and heating prior to X-ray analysis in order to form 10-Å periodic structures. BWA analysis yields the thickness distribution of mixed-layer crystals (coherently diffracting stacks of fundamental illite particles). For most I-S samples, CSD thickness distributions can be approximated by lognormal functions. Mixed-layer crystal mean thickness and expandability then can be used to calculate fundamental illite particle mean thickness. Analyses of the dehydrated, K-saturated samples indicate that basal XRD reflections are broadened by symmetrical strain that may be related to local variations in smectite interlayers caused by dehydration, and that the standard deviation of the strain increases regularly with expandability. The 001 and 002 reflections are affected only slightly by this strain and therefore are suited for CSD thickness analysis. Mean mixed-layer crystal thicknesses for dehydrated I-S measured by the BWA method are very close to those measured by an integral peak width method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsueh, Chun-Hway; Thompson, G. A.; Jadaan, Osama M.
Objectives. The purpose of this study was to analyze the stress distribution through the thickness of bilayered dental ceramics subjected to both thermal stresses and ring-on-ring tests and to systematically examine how the individual layer thickness influences this stress distribution and the failure origin. Methods. Ring-on-ring tests were performed on In-Ceram Alumina/Vitadur Alpha porcelain bilayered disks with porcelain in the tensile side, and In-Ceram Alumina to porcelain layer thickness ratios of 1:2, 1:1, and 2:1 were used to characterize the failure origins as either surface or interface. Based on the thermomechanical properties and thickness of each layer, the cooling temperaturemore » from glass transition temperature, and the ring-on-ring loading configuration, the stress distribution through the thickness of the bilayer was calculated using closed-form solutions. Finite element analyses were also performed to verify the analytical results. Results. The calculated stress distributions showed that the location of maximum tension during testing shifted from the porcelain surface to the In-Ceram Alumina/porcelain interface when the relative layer thickness ratio changed from 1:2 to 1:1 and to 2:1. This trend is in agreement with the experimental observations of the failure origins. Significance. For bilayered dental ceramics subjected to ring-on-ring tests, the location of maximum tension can shift from the surface to the interface depending upon the layer thickness ratio. The closed-form solutions for bilayers subjected to both thermal stresses and ring-on-ring tests are explicitly formulated which allow the biaxial strength of the bilayer to be evaluated.« less
NASA Astrophysics Data System (ADS)
Estep, J. D.; Reece, R.; Kardell, D. A.; Christeson, G. L.; Carlson, R. L.
2017-12-01
Seismic layer 2A, the uppermost igneous portion of oceanic crust, is commonly used to refer to the seismic velocities of upper crust that are bounded below by a steep vertical velocity gradient. Layer 2A velocities are known to increase with crustal age, from 2.5 km/s in crust <1 Ma to 4.5-5 km/s in crust >15 Ma. Thickness of layer 2A has been shown to increase by a factor of 2 within 1 Ma at fast spreading ridges and then remain relatively constant, while layer 2A maintains a fairly consistent thickness, irrespective of age, at slow-intermediate spreading ridges. Layer 2A thickness and velocity evolution studies to date have been largely focused on young oceanic crust very proximal to a spreading center with little investigation of changes (or lack thereof) that occur at crustal ages >10 Ma. We utilize a multichannel seismic dataset collected at 30° S in the western South Atlantic that continuously images 0 - 70 Ma oceanic crust along a single flowline generated at the slow-intermediate spreading Mid-Atlantic Ridge. We follow the methods of previous studies by processing the data to image the layer 2A event, which is then used for calculating thickness. 1D travel time forward modeling at regularly spaced age intervals across the transect provides for the conversion of time to depth thickness, and for determining the evolution of velocities with age. Our results show layer 2A in 20 Ma crust is roughly double the thickness of that in crust 0-5 Ma (830 vs. 440 m), but thickness does not appear to change beyond 20 Ma. The layer 2A event is readily observable in crust 0-50 Ma, is nearly completely absent in crust 50-65 Ma, and then reappears with anomalously high amplitude and lateral continuity in crust 65-70 Ma. Our results suggest that layer 2A thickens with age at the slow-intermediate spreading southern Mid-Atlantic Ridge, and that layer 2A either continues to evolve at the older crustal ages, well beyond the expected 10-15 Ma "mature age", or that external factors have altered the crust at 65-70 Ma. The proximity and thermal influence of the Rio Grande Rise might explain the anomalous appearance of the layer 2A event at the older ages of crust for the study.
Epicardial Adipose Tissue Thickness Independently Predicts Severe Aortic Valve Stenosis.
Mahabadi, Amir A; Kahlert, Heike A; Dykun, Iryna; Balcer, Bastian; Kahlert, Philipp; Rassaf, Tienush
2017-05-01
Epicardial fat tissue (EAT) is associated with coronary as well as aortic valve calcification. The study aim was to determine whether EAT thickness is different in patients with and without aortic valve stenosis (AVS). A cohort of 200 consecutive patients with severe AVS and 200 matched patients without AVS were included retrospectively in the study. EAT thickness was quantified, using transthoracic echocardiography, as the space between the epicardial wall of the myocardium and the visceral layer of the pericardium. Unadjusted and risk factor-adjusted logistic regression analysis was used to determine the association of EAT thickness with the presence of AVS. Overall, 400 patients (182 males, 218 females; mean age 79.6 ± 6.5 years) were included in the study. EAT thickness was significantly higher in patients with severe AVS (7.4 ± 0.3 mm versus 5.8 ± 0.2 mm; p <0.0001 for patients with and without AVS, respectively). In logistic regression analysis, an increase in EAT by one standard deviation was associated with a two-fold increased occurrence of AVS (OR [95%CI]: 2.10 [1.65-2.68]; p <0.0001). Associations remained stable upon adjustment for age, gender and traditional cardiovascular risk factors (2.08 [1.59-2.72]; p <0.0001). Body mass index (BMI) -specific subgroup analysis showed that the link between EAT and AVS was independent of BMI (1.78 [1.15-2.75], 2.62 [1.71- 4.02], and 2.22 [1.36- 3.62], for BMI <25 kg/m2, 25-30 kg/m2, and >30kg/ m2, respectively). EAT, in addition to traditional cardiovascular risk factors, significantly improved the area under the receiver operating characteristic curve (from 0.70 to 0.76; p = 0.003). EAT thickness is significantly associated with severe AVS, independent of traditional risk factors. While further studies are needed to confirm these results, the present findings support the hypothesis that EAT may influence sclerosis of the aortic valve.
Australian Rules football: an anthropometric study of participants.
Burke, L M; Read, R S; Gollan, R A
1985-06-01
Anthropometric measurements and personal data were collected from 119 Australian Rules footballers from Victoria. A top level professional league team, a second level association team, and an A-grade amateur association team were observed, representing three levels of ability. The profile of physical features of these athletes at the beginning of the season is presented. A gradation of body size was observed between teams. The players in the top level team were slightly taller and heavier than those in the other teams. They had less body fat, as shown by lesser skinfold thicknesses, a smaller percentage body fat as determined by prediction equations, and a greater fat-free mass. The intermediate level team showed an intermediate level of body fat and the lower level team had the highest proportion of fat.
Wind and boundary layers in Rayleigh-Bénard convection. II. Boundary layer character and scaling.
van Reeuwijk, Maarten; Jonker, Harm J J; Hanjalić, Kemo
2008-03-01
The scaling of the kinematic boundary layer thickness lambda(u) and the friction factor C(f) at the top and bottom walls of Rayleigh-Bénard convection is studied by direct numerical simulation (DNS). By a detailed analysis of the friction factor, a new parameterisation for C(f) and lambda(u) is proposed. The simulations were made of an L/H=4 aspect-ratio domain with periodic lateral boundary conditions at Ra=(10(5), 10(6), 10(7), 10(8)) and Pr=1. The continuous spectrum, as well as significant forcing due to Reynolds stresses, clearly indicates a turbulent character of the boundary layer, while viscous effects cannot be neglected, judging from the scaling of classical integral boundary layer parameters with Reynolds number. Using a conceptual wind model, we find that the friction factor C(f) should scale proportionally to the thermal boundary layer thickness as C(f) proportional variant lambda(Theta)/H, while the kinetic boundary layer thickness lambda(u) scales inversely proportionally to the thermal boundary layer thickness and wind Reynolds number lambda(u)/H proportional variant (lambda(Theta)/H)(-1)Re(-1). The predicted trends for C(f) and lambda(u) are in agreement with DNS results.
NASA Astrophysics Data System (ADS)
Chadel, Meriem; Chadel, Asma; Moustafa Bouzaki, Mohammed; Aillerie, Michel; Benyoucef, Boumediene; Charles, Jean-Pierre
2017-11-01
Performances of ZnO/ZnS/CZTSSe polycrystalline thin film solar cells (Copper Zinc Tin Sulphur Selenium-solar cell) were simulated for different thicknesses of the absorber and ZnS buffer layers. Simulations were performed with SCAPS (Solar Cell Capacitance Simulator) software, starting with actual parameters available from industrial data for commercial cells processing. The influences of the thickness of the various layers in the structure of the solar cell and the gap profile of the CZTSSe absorber layer on the performance of the solar cell were studied in detail. Through considerations of recent works, we discuss possible routes to enhance the performance of CZTSSe solar cells towards a higher efficiency level. Thus, we found that for one specific thickness of the absorber layer, the efficiency of the CZTSSe solar cell can be increased when a ZnS layer replaces the usual CdS buffer layer. On the other hand, the efficiency of the solar cell can be also improved when the absorber layer presents a grad-gap. In this case, the maximum efficiency for the CZTSSe cell was found equal to 13.73%.
[The role of BCP in electroluminescence of multilayer organic light-emitting devices].
Deng, Zhao-Ru; Yang, Sheng-Yi; Lou, Zhi-Dong; Meng, Ling-Chuan
2009-03-01
As a hole-blocking layer, 2,9-dimethyl-4,7-diphenyl-1,10-phenanthroline (BCP) is usually used in blue and white light electroluminescent devices. The ability of blocking holes of BCP layer depends on its thickness, and basically holes can tunnel through thin BCP layer. In order to know the role of BCP layer in electroluminescence (EL) of multilayer organic light-emitting diodes (OLEDs), in the present paper, the authors designed a multilayer OLED ITO/NPB/BCP/Alq3 : DCJTB/Alq3/Al and investigated the influence of thickness of BCP on the EL spectra of multilayer OLEDs at different applied voltages. The experimental data show that thin BCP layer can block holes partially and tune the energy transfer between different emissive layers, and in this way, it is easy to obtain white emission, but its EL spectra will change with the applied voltages. The EL spectra of multilayer device will remain relatively stable when BCP layer is thick enough, and the holes can hardly tunnel through when the thickness of BCP layer is more than 15 nm. Furthermore, the stability of EL spectra of the multilayer OLED at different applied voltages was discussed.
On determining dead layer and detector thicknesses for a position-sensitive silicon detector
NASA Astrophysics Data System (ADS)
Manfredi, J.; Lee, Jenny; Lynch, W. G.; Niu, C. Y.; Tsang, M. B.; Anderson, C.; Barney, J.; Brown, K. W.; Chajecki, Z.; Chan, K. P.; Chen, G.; Estee, J.; Li, Z.; Pruitt, C.; Rogers, A. M.; Sanetullaev, A.; Setiawan, H.; Showalter, R.; Tsang, C. Y.; Winkelbauer, J. R.; Xiao, Z.; Xu, Z.
2018-04-01
In this work, two particular properties of the position-sensitive, thick silicon detectors (known as the "E" detectors) in the High Resolution Array (HiRA) are investigated: the thickness of the dead layer on the front of the detector, and the overall thickness of the detector itself. The dead layer thickness for each E detector in HiRA is extracted using a measurement of alpha particles emitted from a 212Pb pin source placed close to the detector surface. This procedure also allows for energy calibrations of the E detectors, which are otherwise inaccessible for alpha source calibration as each one is sandwiched between two other detectors. The E detector thickness is obtained from a combination of elastically scattered protons and an energy-loss calculation method. Results from these analyses agree with values provided by the manufacturer.
The Effect of the Thickness of the Sensitive Layer on the Performance of the Accumulating NOx Sensor
Groß, Andrea; Richter, Miriam; Kubinski, David J.; Visser, Jacobus H.; Moos, Ralf
2012-01-01
A novel and promising method to measure low levels of NOx utilizes the accumulating sensor principle. During an integration cycle, incoming NOx molecules are stored in a sensitive layer based on an automotive lean NOx trap (LNT) material that changes its electrical resistivity proportional to the amount of stored NOx, making the sensor suitable for long-term detection of low levels of NOx. In this study, the influence of the thickness of the sensitive layer, prepared by multiple screen-printing, is investigated. All samples show good accumulating sensing properties for both NO and NO2. In accordance to a simplified model, the base resistance of the sensitive layer and the sensitivity to NOx decrease with increasing thickness. Contrarily, the sensor response time increases. The linear measurement range of all samples ends at a sensor response of about 30% resulting in an increase of the linearly detectable amount with the thickness. Hence, the variation of the thickness of the sensitive layer is a powerful tool to adapt the linear measurement range (proportional to the thickness) as well as the sensitivity (proportional to the inverse thickness) to the application requirements. Calculations combining the sensor model with the measurement results indicate that for operation in the linear range, about 3% of the LNT material is converted to nitrate.
Zucchiatti, Ilaria; Cicinelli, Maria V; Parodi, Maurizio Battaglia; Pierro, Luisa; Gagliardi, Marco; Accardo, Agostino; Bandello, Francesco
2017-07-01
To analyze the changes in ganglion cell complex and peripapillary retinal nerve fiber layer thickness, in central macular thickness and choroidal thickness on spectral domain optical coherence tomography in patients with neovascular age-related macular degeneration treated with intravitreal ranibizumab injections. All consecutive patients with untreated neovascular age-related macular degeneration received loading phase of three monthly intravitreal ranibizumab, followed by retreatments on a pro re nata protocol for 12 months. changes in ganglion cell complex and retinal nerve fiber layer at the end of follow-up. Secondary outcome: changes in best-corrected visual acuity, central macular thickness, and choroidal thickness at the end of follow-up. Choroidal thickness was measured at 500 μm, 1000 μm, and 1,500 μm intervals nasally, temporally, superiorly, and inferiorly to the fovea, respectively, on horizontal and vertical line scans centered on the fovea. Twenty-four eyes were included. Ganglion cell complex and peripapillary retinal nerve fiber layer thickness did not show statistically significant changes through 12 months (55.6 ± 18.5 and 81.9 ± 9.9 μm at baseline, 52.7 ± 19.3 and 84.6 ± 15.5 μm at month 12, P > 0.05). Central macular thickness showed progressive decrease from baseline to month 12, with maximum reduction at month 3 (P < 0.001). Statistically significant reduction in choroidal thickness was registered in the nasal 500, 1000, and 1,500 μm from the fovea, corresponding to the papillomacular region (from 169.6 ± 45.3 to 153.9 ± 46.9, P < 0.001). Intravitreal ranibizumab injections did not affect retinal nerve fiber layer and ganglion cell complex thickness in 1-year follow-up. Choroidal thickness in papillomacular area and central macular thickness was significantly reduced at the end of treatment. Further studies, with larger sample, longer follow-up, and greater number of injections, are warranted.
Tensile behavior and flow stress anisotropy of accumulative roll bonded Cu-Nb nanolaminates
Nizolek, Thomas; Beyerlein, Irene J.; Mara, Nathan A.; ...
2016-02-01
The flow stress, ductility, and in-plane anisotropy are evaluated for bulk accumulative roll bonded copper-niobium nanolaminates with layer thicknesses ranging from 1.8 μm to 15 nm. Uniaxial tensile tests conducted parallel to the rolling direction and transverse direction demonstrate that ductility generally decreases with decreasing layer thickness; however, at 30 nm, both high strengths (1200 MPa) and significant ductility (8%) are achieved. The yield strength increases monotonically with decreasing layer thickness, consistent with the Hall-Petch relationship, and significant in-plane flow stress anisotropy is observed. As a result, Taylor polycrystal modeling is used to demonstrate that crystallographic texture is responsible formore » the in-plane anisotropy and that the effects of texture dominate even at nanoscale layer thicknesses.« less
NASA Astrophysics Data System (ADS)
Ilahi, Bouraoui; Al-Saigh, Reem; Salem, Bassem
2017-07-01
The effects of the wetting layer thickness (t WL) on the electronic properties of direct band gap type-I strained dome shaped Ge(1-x)Sn x quantum dot (QD) embedded in Ge matrix is numerically studied. The emission wavelength and the energy difference between S and P electron levels have been evaluated as a function of t WL for different QD size and composition with constant height to diameter ratio. The emission wavelength is found to be red shifted by increasing the wetting layer thickness, with smaller size QD being more sensitive to the variation of t WL. Furthermore, the minimum Sn composition required to fit the directness criteria is found to reduce by increasing the wetting layer thickness.
Theoretical study of ZnS/CdS bi-layer for thin-film CdTe solar cell
NASA Astrophysics Data System (ADS)
Mohamed, H. A.; Mohamed, A. S.; Ali, H. M.
2018-05-01
The performance of CdTe solar cells is strongly limited by the thickness of CdS window layer. A higher short-circuit current density might be achieved by decreasing the thickness of CdS layer as a result of reducing the absorption losses that take place in this layer. However, it is difficult to obtain uniform and pin-hole free CdS layers thinner than 50 nm. This problem can be solved through increasing the band gap of the window layer by adding a wide band gap semiconductor such as ZnS. In this work, bi-layer ZnS/CdS film was studied as an improved window layer of ITO/ZnS/CdS/CdTe solar cell. The total thickness of ZnS/CdS layer was taken about 60 nm. The effect of optical losses due to reflection at different interfaces in the cell and absorption in ITO, ZnS, CdS as well as the recombination loss have been studied. Finally, the effects of the recombination losses in the space-charge region and the reflectivity from the back contact were taken into accounts. The results revealed that the optical losses of 23% were achieved at 60 nm thickness of CdS and theses losses minimized to 18% when ZnS layer of 30 nm thickness was added to CdS layer. The minimum optical and recombination losses of about 26% were obtained at 1 ns of electron life-time and ∼0.4 μm width of the space-charge region. The maximum efficiency of 18.5% was achieved for ITO/CdS/CdTe cell and the efficiency increased up to 20% for ITO/ZnS/CdS/CdTe cell.
Soler García, A; Padilla Parrado, F; Figueroa-Ortiz, L C; González Gómez, A; García-Ben, A; García-Ben, E; García-Campos, J M
2016-01-01
Quantitative assessment of macular and nerve fibre layer thickness in multiple sclerosis patients with regard to expanded disability status scale (EDSS) and presence or absence of previous optic neuritis episodes. We recruited 62 patients with multiple sclerosis (53 relapsing-remitting and 9 secondary progressive) and 12 disease-free controls. All patients underwent an ophthalmological examination, including quantitative analysis of the nerve fibre layer and macular thickness using optical coherence tomography. Patients were classified according to EDSS as A (lower than 1.5), B (between 1.5 and 3.5), and C (above 3.5). Mean nerve fibre layer thickness in control, A, B, and C groups was 103.35±12.62, 99.04±14.35, 93.59±15.41, and 87.36±18.75μm respectively, with statistically significant differences (P<.05). In patients with no history of optic neuritis, history of episodes in the last 3 to 6 months, or history longer than 6 months, mean nerve fibre layer thickness was 99.25±13.71, 93.92±13.30 and 80.07±15.91μm respectively; differences were significant (P<.05). Mean macular thickness in control, A, B, and C groups was 220.01±12.07, 217.78±20.02, 217.68±20.77, and 219.04±24.26μm respectively. Differences were not statistically significant. The mean retinal nerve fibre layer thickness in multiple sclerosis patients is related to the EDSS level. Patients with previous optic neuritis episodes have a thinner retinal nerve fibre layer than patients with no history of these episodes. Mean macular thickness is not correlated to EDSS level. Copyright © 2014 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.
Strain relaxation of thick (11–22) semipolar InGaN layer for long wavelength nitride-based device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jaehwan; Min, Daehong; Jang, Jongjin
2014-10-28
In this study, the properties of thick stress-relaxed (11–22) semipolar InGaN layers were investigated. Owing to the inclination of growth orientation, misfit dislocations (MDs) occurred at the heterointerface when the strain state of the (11–22) semipolar InGaN layers reached the critical point. We found that unlike InGaN layers based on polar and nonpolar growth orientations, the surface morphologies of the stress-relaxed (11–22) semipolar InGaN layers did not differ from each other and were similar to the morphology of the underlying GaN layer. In addition, misfit strain across the whole InGaN layer was gradually relaxed by MD formation at the heterointerface.more » To minimize the effect of surface roughness and defects in GaN layers on the InGaN layer, we conducted further investigation on a thick (11–22) semipolar InGaN layer grown on an epitaxial lateral overgrown GaN template. We found that the lateral indium composition across the whole stress-relaxed InGaN layer was almost uniform. Therefore, thick stress-relaxed (11–22) semipolar InGaN layers are suitable candidates for use as underlying layers in long-wavelength devices, as they can be used to control strain accumulation in the heterostructure active region without additional influence of surface roughness.« less
Niu, Zhi-Guang; Lv, Zhi-Wei; Zhang, Ying; Cui, Zhen-Zhen
2016-02-01
In this paper, the laboratory-scale permeable pavement layers, including a surface permeable brick layer, coarse sand bedding layers (thicknesses = 2, 3.5, and 5 cm), and single-graded gravel sub-base layers (thicknesses = 15, 20, 25, and 30 cm), were built to evaluate stormwater infiltration and surface runoff pollution reduction performance. And, the infiltration rate (I) and concentrations of suspended solids (SS), total phosphorus (TP), chemical oxygen demand (COD), ammonia nitrogen, and total nitrogen (TN) were measured under the simulated rainfall intensity of 72.4 mm/h over duration of 60 min. The results indicate that the thickness factor primarily influences the infiltration rate and pollutant removal rate. The highest steady infiltration rate was for surface brick layer 51.0 mm/h, for 5-cm sand bedding layer 32.3 mm/h, and for 30-cm gravel sub-base layer 42.3 mm/h, respectively. The SS average removal rate was relative higher (79.8 ∼ 98.6 %) for all layers due to the interception and filtration. The average removal rates of TP and COD were for surface layer 71.2 and 24.1 %, for 5-cm bedding layer 54.8 and 9.0 %, and for 20-cm sub-base layer 72.2 and 26.1 %. Ammonia nitrogen and TN cannot steadily be removed by layers according to the experiment results. The optimal thickness of bedding sands was 5 cm, and that of sub-base gravels was 20 ∼ 30 cm.
Current-induced switching in CoGa/L10 MnGa/(CoGa)/Pt structure with different thicknesses
NASA Astrophysics Data System (ADS)
Ranjbar, R.; Suzuki, K. Z.; Mizukami, S.
2018-06-01
In this paper, we present the results of our study into current-induced spin-orbit torque (SOT) switching in perpendicularly magnetized CoGa/MnGa/Pt trilayers with different thicknesses of MnGa and Pt. The SOT switching was observed for all films that undergo Joule heating. We also investigate SOT switching in the bottom (CoGa)/MnGa/top(CoGa/Pt) films with different top layers. Although both the bottom and top layers contribute to the SOT, the relative magnitudes of the switching current densities JC in the top and bottom layers indicate that the SOT is dominant in the top layer. The JC as a function of thickness is discussed in terms of the magnetic properties and resistivity. Experimental data suggested that the MnGa thickness dependence of JC may originate from the perpendicular magnetic anisotropy thickness product Kueff t value. On the other hand, JC as a function of the Pt thickness shows weak dependence. This may be attributed to the slight change of spin-Hall angle θSH value with different thicknesses of Pt, when we assumed that the SOT switching is primarily due to the spin-Hall effect.
Wan, Yi; Jin, Sihua; Ma, Chendong; Wang, Zhicheng; Fang, Qi; Jiang, Runshen
2017-12-22
Eggs with a much higher proportion of thick albumen are preferred in the layer industry, as they are favoured by consumers. However, the genetic factors affecting the thick egg albumen trait have not been elucidated. Using RNA sequencing, we explored the magnum transcriptome in 9 Rhode Island white layers: four layers with phenotypes of extremely high ratios of thick to thin albumen (high thick albumen, HTA) and five with extremely low ratios (low thick albumen, LTA). A total of 220 genes were differentially expressed, among which 150 genes were up-regulated and 70 were down-regulated in the HTA group compared with the LTA group. Gene Ontology (GO) analysis revealed that the up-regulated genes in HTA were mainly involved in a wide range of regulatory functions. In addition, a large number of these genes were related to glycosphingolipid biosynthesis, focal adhesion, ECM-receptor interactions and cytokine-cytokine receptor interactions. Based on functional analysis, ST3GAL4, FUT4, ITGA2, SDC3, PRLR, CDH4 and GALNT9 were identified as promising candidate genes for thick albumen synthesis and metabolism during egg formation. These results provide new insights into the molecular mechanisms of egg albumen traits and may contribute to future breeding strategies that optimise the proportion of thick egg albumen.
Lima, Manoel C. S.; Barbosa, Maurício F.; Diniz, Tiego A.; Codogno, Jamile S.; Freitas, Ismael F.; Fernandes, Rômulo A.
2014-01-01
Background: It is unclear whether early physical activity has a greater influence on intima-media thickness and metabolic variables than current physical activity. Objective: To analyze the relationship between current and early physical activity, metabolic variables, and intima-media thickness measures in adults. Method: The sample was composed of 55 healthy subjects of both sexes (33 men and 22 women). Total body fat and trunk fat were estimated by dual-energy X-ray absorptiometry. Carotid and femoral intima-media thickness were measured using a Doppler ultrasound device. A 12-hour fasting blood sample collection was taken (fasting glucose and lipid profile). Early physical activity was assessed through face-to-face interview, and the current physical activity was assessed by pedometer (Digi-Walker Yamax, SW200), which was used for a period of seven days. Results: Current physical activity was negatively related to total cholesterol (rho=-0.31), while early physical activity was negatively related to triglycerides (rho=-0.42), total cholesterol (rho=-0.28), very low density lipoprotein (rho=-0.44), and carotid intima-media thickness (rho=-0.50). In the multivariate model, subjects engaged in sports activities during early life had lower values of very low density lipoprotein (b=-8.74 [b=-16.1; -1.47]) and carotid intima-media thickness (b=-0.17 [95%CI: -0.28; -0.05]). Conclusion: Early 95%CI physical activity has a significant influence on carotid intima-media thickness, regardless of the current physical activity. PMID:25372009
Lima, Manoel C S; Barbosa, Maurício F; Diniz, Tiego A; Codogno, Jamile S; Freitas Júnior, Ismael F; Fernandes, Rômulo A
2014-01-01
It is unclear whether early physical activity has a greater influence on intima-media thickness and metabolic variables than current physical activity. To analyze the relationship between current and early physical activity, metabolic variables, and intima-media thickness measures in adults. The sample was composed of 55 healthy subjects of both sexes (33 men and 22 women). Total body fat and trunk fat were estimated by dual-energy X-ray absorptiometry. Carotid and femoral intima-media thickness were measured using a Doppler ultrasound device. A 12-hour fasting blood sample collection was taken (fasting glucose and lipid profile). Early physical activity was assessed through face-to-face interview, and the current physical activity was assessed by pedometer (Digi-Walker Yamax, SW200), which was used for a period of seven days. Current physical activity was negatively related to total cholesterol (rho=-0.31), while early physical activity was negatively related to triglycerides (rho=-0.42), total cholesterol (rho=-0.28), very low density lipoprotein (rho=-0.44), and carotid intima-media thickness (rho=-0.50). In the multivariate model, subjects engaged in sports activities during early life had lower values of very low density lipoprotein (b=-8.74 [b95%CI=-16.1; -1.47]) and carotid intima-media thickness (b=-0.17 [95%CI: -0.28; -0.05]). Early 95%CI physical activity has a significant influence on carotid intima-media thickness, regardless of the current physical activity.
Indium oxide based fiber optic SPR sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shukla, Sarika; Sharma, Navneet K., E-mail: navneetk.sharma@jiit.ac.in
2016-05-06
Surface plasmon resonance based fiber optic sensor using indium oxide layer is presented and theoretically studied. It has been found that with increase in thickness of indium oxide layer beyond 170 nm, the sensitivity of SPR sensor decreases. 170 nm thick indium oxide layer based SPR sensor holds maximum sensitivity.
Hybrid ZnO/phthalocyanine photovoltaic device with highly resistive ZnO intermediate layer.
Izaki, Masanobu; Chizaki, Ryo; Saito, Takamasa; Murata, Kazufumi; Sasano, Junji; Shinagawa, Tsutomu
2013-10-09
We report a hybrid photovoltaic device composed of a 3.3 eV bandgap zinc oxide (ZnO) semiconductor and metal-free phthalocyanine layers and the effects of the insertion of the highly resistive ZnO buffer layer on the electrical characteristics of the rectification feature and photovoltaic performance. The hybrid photovoltaic devices have been constructed by electrodeposition of the 300 nm thick ZnO layer in a simple zinc nitrate aqueous solution followed by vacuum evaporation of 50-400 nm thick-phthalocyanine layers. The ZnO layers with the resistivity of 1.8 × 10(3) and 1 × 10(8) Ω cm were prepared by adjusting the cathodic current density and were installed into the hybrid photovoltaic devices as the n-type and buffer layer, respectively. The phthalocyanine layers with the characteristic monoclinic lattice showed a characteristic optical absorption feature regardless of the thickness, but the preferred orientation changed depending on the thickness. The ZnO buffer-free hybrid 50 nm thick phthalocyanine/n-ZnO photovoltaic device showed a rectification feature but possessed a poor photovoltaic performance with a conversion efficiency of 7.5 × 10(-7) %, open circuit voltage of 0.041 V, and short circuit current density of 8.0 × 10(-5) mA cm(-2). The insertion of the ZnO buffer layer between the n-ZnO and phthalocyanine layers induced improvements in both the rectification feature and photovoltaic performance. The excellent rectification feature with a rectification ratio of 3188 and ideally factor of 1.29 was obtained for the hybrid 200 nm thick phthalocyanine/ZnO buffer/n-ZnO photovoltaic device, and the hybrid photovoltaic device possessed an improved photovoltaic performance with the conversion efficiency of 0.0016%, open circuit voltage of 0.31 V, and short circuit current density of 0.015 mA cm(-2).
USDA-ARS?s Scientific Manuscript database
The objective was to study alternative models for genetic analyses of carcass traits assessed by ultrasonography in Guzerá cattle. Data from 947 measurements (655 animals) of Rib-eye area (REA), rump fat thickness (RFT) and backfat thickness (BFT) were used. Finite polygenic models (FPM), infinitesi...
Controlling contamination in Mo/Si multilayer mirrors by Si surface capping modifications
NASA Astrophysics Data System (ADS)
Malinowski, Michael E.; Steinhaus, Chip; Clift, W. Miles; Klebanoff, Leonard E.; Mrowka, Stanley; Soufli, Regina
2002-07-01
The performance of Mo/Si multilayer mirrors (MLMs) used to reflect UV (EUV) radiation in an EUV + hydrocarbon (NC) vapor environment can be improved by optimizing the silicon capping layer thickness on the MLM in order to minimize the initial buildup of carbon on MLMs. Carbon buildup is undesirable since it can absorb EUV radiation and reduce MLM reflectivity. A set of Mo/Si MLMs deposited on Si wafers was fabricated such that each MLM had a different Si capping layer thickness ranging form 2 nm to 7 nm. Samples from each MLM wafer were exposed to a combination of EUV light + (HC) vapors at the Advanced Light Source (ALS) synchrotron in order to determine if the Si capping layer thickness affected the carbon buildup on the MLMs. It was found that the capping layer thickness had a major influence on this 'carbonizing' tendency, with the 3 nm layer thickness providing the best initial resistance to carbonizing and accompanying EUV reflectivity loss in the MLM. The Si capping layer thickness deposited on a typical EUV optic is 4.3 nm. Measurements of the absolute reflectivities performed on the Calibration and Standards beamline at the ALS indicated the EUV reflectivity of the 3 nm-capped MLM was actually slightly higher than that of the normal, 4 nm Si-capped sample. These results show that he use of a 3 nm capping layer represents an improvement over the 4 nm layer since the 3 nm has both a higher absolute reflectivity and better initial resistance to carbon buildup. The results also support the general concept of minimizing the electric field intensity at the MLM surface to minimize photoelectron production and, correspondingly, carbon buildup in a EUV + HC vapor environment.
Opieliński, Krzysztof J; Gudra, Tadeusz
2002-05-01
The effective ultrasonic energy radiation into the air of piezoelectric transducers requires using multilayer matching systems with accurately selected acoustic impedances and the thickness of particular layers. This problem is of particular importance in the case of ultrasonic transducers working at a frequency above 1 MHz. Because the possibilities of choosing material with required acoustic impedance are limited (the counted values cannot always be realised and applied in practice) it is necessary to correct the differences between theoretical values and the possibilities of practical application of given acoustic impedances. Such a correction can be done by manipulating other parameters of matching layers (e.g. by changing their thickness). The efficiency of the energy transmission from the piezoceramic transducer through different layers with different thickness enabling a compensation of non-ideal real values by changing their thickness was computer analysed. The result of this analysis is the conclusion that from the technological point of view a layer with defined thickness is easier and faster to produce than elaboration of a new material with required acoustic parameter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sahoo, S. K.; Misra, D.; Agrawal, D. C.
2011-01-01
Recently, high K materials play an important role in microelectronic devices such as capacitors, memory devices, and microwave devices. Now a days ferroelectric barium strontium titanate [Ba{sub x}Sr{sub 1-x}TiO{sub 3}, (BST)] thin film is being actively investigated for applications in dynamic random access memories (DRAM), field effect transistor (FET), and tunable devices because of its properties such as high dielectric constant, low leakage current, low dielectric loss, and high dielectric breakdown strength. Several approaches have been used to optimize the dielectric and electrical properties of BST thin films such as doping, graded compositions, and multilayer structures. We have found thatmore » inserting a ZrO{sub 2} layer in between two BST layers results in a significant reduction in dielectric constant, loss tangent, and leakage current in the multilayer thin films. Also it is shown that the properties of multilayer structure are found to depend strongly on the sublayer thicknesses. In this work the effect of ZrO{sub 2} layer thickness on the dielectric, ferroelectric as well as electrical properties of BST/ZrO{sub 2}/BST multilayer structure is studied. The multilayer Ba{sub 0.8}Sr{sub 0.2}TiO{sub 3}/ZrO{sub 2}/Ba{sub 0.8}Sr{sub 0.2}TiO{sub 3} film is deposited by a sol-gel process on the platinized Si substrate. The thickness of the middle ZrO{sub 2} layer is varied while keeping the top and bottom BST layer thickness as fixed. It is observed that the dielectric constant, dielectric loss tangent, and leakage current of the multilayer films reduce with the increase of ZrO{sub 2} layer thickness and hence suitable for memory device applications. The ferroelectric properties of the multilayer film also decrease with the ZrO{sub 2} layer thickness.« less
Body fat at pubertal genital stage 2: a comparison between Spanish and Mexican boys.
Vizmanos, B; Llop-Viñolas, D; Quezada-Figueroa, N; Sánchez-Sucilla, M; Fernández-Ballart, J D; Salcedo-Rocha, A L; Vásquez-Garibay, E M; Martí-Henneberg, C
2009-06-01
To compare body fat mass at the same stage of pubertal maturation, genital stage 2 (G2), in a Spanish and in a Mexican sample of boys. Data from Spain (n=177) were from a previous longitudinal clinical follow-up and data from Mexico (n=91) from a cross-sectional study. Subjects were grouped according to the presence of G2 at similar ages. Spanish sample was divided into boys with G2 at age 12 (n=60), 13 (n=74) and 14 (n=43). In Mexican sample, 23 boys were at G2 at 12 years, 38 at age 13 and 30 at 14 years. Height, weight, upper arm circumference and four skinfold thicknesses were recorded. Genital development was assessed (Tanner scale). Sum of four skinfolds (SUM), body mass index (BMI), percentage of body fat (%BF) and extremity/trunk skinfold ratio (ETR=(triceps+biceps)/(subscapular+suprailiac)) was calculated. When comparing subjects with different ages at G2 from the same country, or with the same age at G2 from different countries, no significant differences were found in adiposity variables (%BF, SUM), nor in BMI. Nevertheless, there were differences in body fat distribution: ETR was higher in Spanish boys (P<0.001), because of their greater triceps skinfold thickness (P=0.013), and due to the greater trunk fat stores in Mexican boys (P<0.01, subscapular and suprailiac skinfolds). There is a subcutaneous fat mass store characteristic of G2 in boys, which is not only independent of age, but is also observable in two different populations.
Fernández Muñoz, María J; Basurto Acevedo, Lourdes; Córdova Pérez, Nydia; Vázquez Martínez, Ana Laura; Tepach Gutiérrez, Nayive; Vega García, Sara; Rocha Cruz, Alberto; Díaz Martínez, Alma; Saucedo García, Renata; Zárate Treviño, Arturo; González Escudero, Eduardo Alberto; Degollado Córdova, José Antonio
2014-06-01
Epicardial adipose tissue has been associated with several obesity-related parameters and with insulin resistance. Echocardiographic assessment of this tissue is an easy and reliable marker of cardiometabolic risk. However, there are insufficient studies on the relationship between epicardial fat and insulin resistance during the postmenopausal period, when cardiovascular risk increases in women. The objective of this study was to examine the association between epicardial adipose tissue and visceral adipose tissue, waist circumference, body mass index, and insulin resistance in postmenopausal women. A cross sectional study was conducted in 34 postmenopausal women with and without metabolic syndrome. All participants underwent a transthoracic echocardiogram and body composition analysis. A positive correlation was observed between epicardial fat and visceral adipose tissue, body mass index, and waist circumference. The values of these correlations of epicardial fat thickness overlying the aorta-right ventricle were r = 0.505 (P < .003), r = 0.545 (P < .001), and r = 0.515 (P < .003), respectively. Epicardial adipose tissue was higher in postmenopausal women with metabolic syndrome than in those without this syndrome (mean [standard deviation], 544.2 [122.9] vs 363.6 [162.3] mm(2); P = .03). Epicardial fat thickness measured by echocardiography was associated with visceral adipose tissue and other obesity parameters. Epicardial adipose tissue was higher in postmenopausal women with metabolic syndrome. Therefore, echocardiographic assessment of epicardial fat may be a simple and reliable marker of cardiovascular risk in postmenopausal women. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Etchison, William C; Bloodgood, Elizabeth A; Minton, Cholly P; Thompson, Nancy J; Collins, Mary Ann; Hunter, Stephen C; Dai, Hongying
2011-05-01
Body mass index (BMI) is widely accepted in determining obesity. Skinfold thickness measurements have been commonly used to determine percentage of body fat. The authors hypothesize that because BMI does not measure fat directly but relies on body weight alone, a large percentage of athletic adolescents will be misclassified as obese by BMI. Cross-sectional study. To compare BMI and skinfold measurements as indicators for obesity in the adolescent athletic population, anthropometric data (height, weight, percentage body fat, age, and sex) were recorded from 33 896 student athletes (average age, 15 years; range, 11-19 years) during preparticipation physical examinations from 1985 to 2003. BMI was calculated from height and weight. Percentage of body fat was determined by measuring skinfold thickness. According to their BMI percentile, 13.31% of adolescent athletes were obese. Using the skinfold method, only 5.95% were obese. Of those classified as obese by the BMI, 62% were considered false positives by the skinfold method. In contrast, there was a 99% probability that the nonobese by BMI would not be obese by the skinfold method (negative predictive value = 0.99). BMI is a measurement of relative body weight, not body composition. Because lean mass weighs far more than fat, many adolescent athletes are incorrectly classified as obese based on BMI. Skinfold testing provides a more accurate body assessment than BMI in adolescent athletes. Correct body composition data can help to provide better diet and activity guidelines and prevent the psychological problems associated with being labeled as obese.
Teaima, Mahmoud H; Abdelhalim, Sally A; El-Nabarawi, Mohamed A; Attia, Dalia A; Helal, Doaa A
2018-01-01
Cellulite is a common topographical alteration where skin acquires an orange peel or mattress appearance with alterations in adipose tissue and microcirculation. This work aims to develop and evaluate a topical niosomal gel formulae with good permeation to reach the subcutaneous fat layer. Several caffeine niosomal dispersions were prepared and incorporated into gel formulae using Carbopol 940 polymer, chemical penetration enhancers, and iontophoresis, then the prepared gels were applied onto the skin of rats and anticellulite activity of caffeine from the prepared gels compared to that of the commercial product Cellu Destock ® was evaluated by histological study of the skin and measurement of plasma level of caffeine passing through the skin using liquid chromatography (LC/MS-MS). Results of histology revealed reduction of size and thickness of fatty layer of rat skin in the following order: FVII > FXIV > Cellu Destock ® > FVII + Iontophoresis > FXIV + Iontophoresis. Pharmacokinetic results of caffeine in plasma revealed that C max , T max , and AUC 0-12h decreased in the following order: FXIV > FVII > Cellu Destock ® . These results conclude that incorporation of caffeine niosomal dispersion into gel matrix with penetration enhancers and iontophoresis resulted in improvement in penetration of caffeine through the skin into the underlying fatty layer in treatment of cellulite.
Effects of castration and time-on-feed on Mertolenga breed beef quality.
Monteiro, A C G; Navas, D R; Lemos, J P C
2014-04-01
Physicochemical characteristics were determined in the longissimus lumborum muscle, after 8 days of ageing of steers (n=12) and bulls (n=12) from Mertolenga breed slaughtered directly from pasture (day 0) or after a finishing period of 50, 100 and 150 days in a feed-lot facility. Bulls and steers presented similar live weight (averaging 388 kg), carcass weight (CW; averaging 213 kg), dressing percentage (averaging 60%), carcass fatness (11.9% CW) and carcass fat thickness (averaging 3.03 mm). Live weight, CW, carcass fatness and fat thickness increased along time-on-feed. Gender only had a negligible effect on meat characteristics, with b and h being the only parameters of colour affected by gender, also presenting a significant interaction gender × time-on-feed. Nevertheless, both the genders presented a high-quality grade concerning tenderness (Warner-Bratzler shear force (WBSF)). L increased until 50 days on feed and decreased afterwards, whereas a and C values increased along time-on-feed. Pigment content was also affected by time-on-feed and showed a gender × time-on-feed interaction. Beef colour became darker and redder along time-on-feed, but still in a colour range highly acceptable by Portuguese consumers. Despite the increase in intramuscular fat and myofibrillar fragmentation index, as well as the decrease in collagen content of steers and bulls along time-on-feed, it did not affect the tenderness/hardness, indicating a small effect of time-on-feed in meat characteristics. Despite only small differences in carcass characteristics and meat-quality parameters that have been noticed along time-on-feed, those differences were only significant after 100 days on feed. Principal component analysis (PCA) was performed. The first PC axis (39.6% of the total variance) included colour variables a, b and C, and carcass fatness, fat thickness, CW and live weight, whereas the second one (12.7% of the total variance) included h, cooking losses and dressing-out. The principal component (PC) analysis confirmed the lack of differences between bulls and steers and indicates a differentiation of the first two periods of feeding (0 and 50 days on feed) from the two latter (100 and 150 days on feed) periods of feeding.
Long-Wavelength Instability in Marangoni Convection
NASA Technical Reports Server (NTRS)
VanHook, Stephen J.; Schatz, Michael F.; Swift, Jack B.; McCormick, W. D.; Swinney, Harry L.
1996-01-01
Our experiments in thin liquid layers (approximately 0.1 mm thick) heated from below reveal a well-defined long-wavelength instability: at a critical temperature difference across the layer, the depth of the layer in the center of the cell spontaneously decreases until the liquid-air interface ruptures and a dry spot forms. The onset of this critical instability occurs at a temperature difference across the liquid layer that is 35% smaller than that predicted in earlier theoretical studies of a single layer model. Our analysis of a two-layer model yields predictions in accord with the observations for liquid layer depths greater than or equal to 0.15 mm, but for smaller depths there is an increasing difference between our predictions and observations (the difference is 25% for a layer 0.06 mm thick). In microgravity environments the long-wavelength instability observed in our terrestrial experiments is expected to replace cellular convection as the primary instability in thick as well as thin liquid layers heated quasistatically from below.
Polymer thin film as coating layer to prevent corrosion of metal/metal oxide film
NASA Astrophysics Data System (ADS)
Sarkar, Suman; Kundu, Sarathi
2018-04-01
Thin film of polymer is used as coating layer and the corrosion of metal/metal oxide layer is studied with the variation of the thickness of the coating layer. The thin layer of polystyrene is fabricated using spin coating method on copper oxide (CuO) film which is deposited on glass substrate using DC magnetron sputtering technique. Thickness of the polystyrene and the CuO layers are determined using X-ray reflectivity (XRR) technique. CuO thin films coated with the polystyrene layer are exposed to acetic acid (2.5 v/v% aqueous CH3COOH solution) environments and are subsequently analyzed using UV-Vis spectroscopy and atomic force microscopy (AFM). Surface morphology of the film before and after interaction with the acidic environment is determined using AFM. Results obtained from the XRR and UV-Vis spectroscopy confirm that the thin film of polystyrene acts as an anticorrosion coating layer and the strength of the coating depends upon the polymer layer thickness at a constant acid concentration.
Zhang, Xia; Ma, Jin; Wang, Yuhan; Li, Lüe; Gao, Lu; Guo, Xiaopeng; Xing, Bing; Zhong, Yong
2018-03-01
1) To compare the retinal, choroidal, Haller's layer, and Sattler's/choriocapillaris thicknesses of untreated acromegaly patients without chiasm compression or diabetes mellitus and healthy controls. 2) To evaluate the correlations of retinal and choroidal thicknesses with serum growth hormone (GH) and insulin-like growth factor 1 (IGF) burden. This prospective, case-control study included 27 untreated acromegaly patients and 27 sex-matched and age-matched controls. Subfoveal choroidal, Haller's layer and Sattler's/choriocapillaris thicknesses were determined by enhanced-depth imaging optical coherence tomography (EDI-OCT). Foveal and macular retinal thicknesses were determined with SD-OCT. GH and IGF-1 burdens were defined as the product of disease duration and treatment-naïve serum GH and IGF-1 levels. Compared with healthy controls, patients with acromegaly exhibited significantly increased foveal retinal (p = 0.003), subfoveal choroidal (p < 0.001), and Haller's layer (p < 0.001) thicknesses, with no differences in Sattler's/choriocapillaris layer thickness. Multiple point measurements in the posterior pole area showed equally increased nasal and temporal parts of the choroid. The retinal thickness maps of the two groups did not significantly differ. Correlation analysis indicated that choroidal thickness was significantly correlated with disease duration (p = 0.01), serum IGF-1 level (p = 0.03) and IGF-1 burden (p = 0.009). No significant correlations were detected between choroidal thickness and GH burden (p = 0.44). Retinal thickness was not significantly correlated with any factor. The choroidal thickness of acromegaly patients was greater than that of healthy controls and was significantly correlated with disease duration, IGF-1 level and IGF-1 burden, indicating that excessive serum IGF-1 and its exposure time have a combined effect on choroidal thickness.
An achromatic four-mirror compensator for spectral ellipsometers
NASA Astrophysics Data System (ADS)
Kovalev, V. I.; Rukovishnikov, A. I.; Kovalev, S. V.; Kovalev, V. V.; Rossukanyi, N. M.
2017-07-01
Measurement and calculation results are presented that confirm that design four-mirror compensators can be designed for the spectral range of 200-2000 nm that is widely used in modern spectral ellipsometers. Measurements and calculations according to standard ellipsometric programs have been carried out on a broadband LED spectral ellipsometer with switching of orthogonal polarization states. Mirrors with the structure of glass substrate/Al2O3 layer (20-30 nm thick)/Al layer (150 nm thick)/upper Al2O3 layer (with specified thickness d) have been prepared by vacuum-evaporation method. It is shown that the phase-shift spectra of a four-mirror compensator, two mirrors of which have a native oxide 5.5 nm thick and the two others of which have an oxide layer 36 nm thick, measured on the ellipsometer, are flattened in comparison with similar spectra of a compensator, all four mirrors of which have a native oxide, especially in the short-wavelength spectral region. The results of calculating the phase-shift spectra of the four-mirror compensator with six variable parameters (angles of incidence of radiation on the mirrors and thicknesses of oxide layers on four mirrors) are presented. High-quality achromatization in a wide spectral range can be achieved for certain sets of parameters.
Liang, Yuan-Chang; Lo, Ya-Ru; Wang, Chein-Chung; Xu, Nian-Cih
2018-01-01
ZnO-ZnS core-shell nanorods are synthesized by combining the hydrothermal method and vacuum sputtering. The core-shell nanorods with variable ZnS shell thickness (7–46 nm) are synthesized by varying ZnS sputtering duration. Structural analyses demonstrated that the as-grown ZnS shell layers are well crystallized with preferring growth direction of ZnS (002). The sputtering-assisted synthesized ZnO-ZnS core-shell nanorods are in a wurtzite structure. Moreover, photoluminance spectral analysis indicated that the introduction of a ZnS shell layer improved the photoexcited electron and hole separation efficiency of the ZnO nanorods. A strong correlation between effective charge separation and the shell thickness aids the photocatalytic behavior of the nanorods and improves their photoresponsive nature. The results of comparative degradation efficiency toward methylene blue showed that the ZnO-ZnS nanorods with the shell thickness of approximately 17 nm have the highest photocatalytic performance than the ZnO-ZnS nanorods with other shell layer thicknesses. The highly reusable catalytic efficiency and superior photocatalytic performance of the ZnO-ZnS nanorods with 17 nm-thick ZnS shell layer supports their potential for environmental applications. PMID:29316671
Multilayer Black Phosphorus Near-Infrared Photodetectors.
Hou, Chaojian; Yang, Lijun; Li, Bo; Zhang, Qihan; Li, Yuefeng; Yue, Qiuyang; Wang, Yang; Yang, Zhan; Dong, Lixin
2018-05-23
Black phosphorus (BP), owing to its distinguished properties, has become one of the most competitive candidates for photodetectors. However, there has been little attention paid on photo-response performance of multilayer BP nanoflakes with large layer thickness. In fact, multilayer BP nanoflakes with large layer thickness have greater potential from the fabrication viewpoint as well as due to the physical properties than single or few layer ones. In this report, the thickness-dependence of the intrinsic property of BP photodetectors in the dark was initially investigated. Then the photo-response performance (including responsivity, photo-gain, photo-switching time, noise equivalent power, and specific detectivity) of BP photodetectors with relative thicker thickness was explored under a near-infrared laser beam ( λ IR = 830 nm). Our experimental results reveal the impact of BP's thickness on the current intensity of the channel and show degenerated p-type BP is beneficial for larger current intensity. More importantly, the photo-response of our thicker BP photodetectors exhibited a larger responsivity up to 2.42 A/W than the few-layer ones and a fast response photo-switching speed (response time is ~2.5 ms) comparable to thinner BP nanoflakes was obtained, indicating BP nanoflakes with larger layer thickness are also promising for application for ultra-fast and ultra-high near-infrared photodetectors.
Gravitational instability of thin gas layer between two thick liquid layers
NASA Astrophysics Data System (ADS)
Pimenova, A. V.; Goldobin, D. S.
2016-12-01
We consider the problem of gravitational instability (Rayleigh-Taylor instability) of a horizontal thin gas layer between two liquid half-spaces (or thick layers), where the light liquid overlies the heavy one. This study is motivated by the phenomenon of boiling at the surface of direct contact between two immiscible liquids, where the rate of the "break-away" of the vapor layer growing at the contact interface due to development of the Rayleigh-Taylor instability on the upper liquid-gas interface is of interest. The problem is solved analytically under the assumptions of inviscid liquids and viscous weightless vapor. These assumptions correspond well to the processes in real systems, e.g., they are relevant for the case of interfacial boiling in the system water- n-heptane. In order to verify the results, the limiting cases of infinitely thin and infinitely thick gas layers were considered, for which the results can be obviously deduced from the classical problem of the Rayleigh-Taylor instability. These limiting cases are completely identical to the well-studied cases of gravity waves at the liquidliquid and liquid-gas interfaces. When the horizontal extent of the system is long enough, the wavenumber of perturbations is not limited from below, and the system is always unstable. The wavelength of the most dangerous perturbations and the rate of their exponential growth are derived as a function of the layer thickness. The dependence of the exponential growth rate on the gas layer thickness is cubic.
Comparison of reproduce signal and noise of conventional and keepered CoCrTa/Cr thin film media
NASA Astrophysics Data System (ADS)
Sin, Kyusik; Ding, Juren; Glijer, Pawel; Sivertsen, John M.; Judy, Jack H.; Zhu, Jian-Gang
1994-05-01
We studied keepered high coercivity CoCrTa/Cr thin film media with a Cr isolation layer between the CoCrTa storage and an overcoating of an isotropic NiFe soft magnetic layer. The influence of the thickness of the NiFe and Cr layers, and the effects of head bias current on the signal output and noise, were studied using a thin film head. The reproduced signal increased by 7.3 dB, but the signal-to-noise ratio decreased by 4 dB at a linear density of 2100 fr/mm (53.3 kfr/in.) with a 1000 Å thick NiFe keeper layer. The medium noise increased with increasing NiFe thickness and the signal output decreased with decreasing Cr thickness. A low output signal obtained with very thin Cr may be due to magnetic interactions between the keeper layer and magnetic media layer. It is observed that signal distortion and timing asymmetry of the output signals depend on the thickness of the keeper layer and the head bias current. The signal distortion increased and the timing asymmetry decreased as the head bias current was increased. These results may be associated with different permeability of the keeper under the poles of the thin film head due to the superposition of head bias and bit fields.
On the meaning of the diffusion layer thickness for slow electrode reactions.
Molina, A; González, J; Laborda, E; Compton, R G
2013-02-21
A key concept underpinning electrochemical science is that of the diffusion layer - the zone of depletion around an electrode accompanying electrolysis. The size of this zone can be found either from the simulated or measured concentration profiles (yielding the 'true' diffusion layer thickness) or, in the case of the Nernst ('linear') diffusion layer by extrapolating the concentration gradient at the electrode surface to the distance at which the concentration takes its bulk value. The latter concept is very well developed in the case of fast (so-called reversible) electrode processes, however the study of the linear diffusion layer has received scant attention in the case of slow charge transfer processes, despite its study being of great interest in the analysis of the influence of different experimental variables which determine the electrochemical response. Analytical explicit solutions for the concentration profiles, surface concentrations and real and linear diffusion layers corresponding to the application of a potential step to a slow charge transfer process are presented. From these expressions the dependence of the diffusion layer thickness on the potential, pulse time, heterogeneous rate constant and ratio of bulk concentrations of electroactive species and of diffusion coefficients is quantified. A profound influence of the reversibility degree of the charge transfer on the diffusion layer thickness is clear, showing that for non-reversible processes the real and linear diffusion layers reveal a minimum thickness which coincides with the equilibrium potential of the redox couple in the former case and with the reversible half-wave potential in the latter one.
Jones, Isabela T; Vanaman Wilson, Monique J; Guiha, Isabella; Wu, Douglas C; Goldman, Mitchel P
2018-01-13
Cryolipolysis is a non-invasive method of body shaping that has been used for male pseudogynecomastia. However, traditional vacuum suction cryolipolysis requires a minimum pinchable fat layer which may not always be present in this area. To evaluate the efficacy and safety of a conformable surface cryolipolysis applicator for the reduction of male pseudogynecomastia. Ten male subjects with pseudogynecomastia received two cycles of cryolipolysis to the breast 6 weeks apart. Ultrasound was used to measure the thickness of adipose tissue. Seven of 10 patients completed the study. Compared to baseline, the mean ± SD change in adipose tissue thickness was 8.12 ± 6.94 mm for the treated versus 1.03 ± 6.03 mm for the control breast at week 6 (p = 0.014), and 8.71 ± 7.04 mm for the treated vs. 2.66 ± 7.04 mm for the control breast at week 12 (P = 0.16). Four (4) of seven (57%) patients were at least slightly satisfied with the treated breast, and although subject satisfaction was higher in the treated breast, this did not reach significance (0.085). Adverse events were mild and transient. A conformable surface cryolipolysis applicator was effective in reducing the mean adipose tissue thickness in subjects with male pseudogynecomastia. Lasers Surg. Med. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Li, Mingtao; Li, Wenlian; Chen, Lili; Kong, Zhiguo; Chu, Bei; Li, Bin; Hu, Zhizhi; Zhang, Zhiqiang
2006-02-01
Electroluminescent colors of organic light-emitting diodes (OLEDs) can be tuned by modulating the thickness of gadolinium (Gd) complex layer sandwiched between an electron-transporting layer (ETL) and a hole-transporting layer (HTL). The emission colors, which originate from the two interfacial exciplexes simultaneously, can be tuned from green to orange by increasing the thickness of the Gd-complex layer. The atom force microscope images have proved that there are many gaps in the thinner Gd-complex layers. Therefore, besides the exciplex formation between Gd complex and HTL, the exciplex between ETL and HTL is also formed. The results demonstrate that a simple way of color tuning can be realized by inserting a thin layer of color tuning material between HTL with lower ionization potentials and ETL with higher electron affinities. Moreover, photovoltaic device and white OLED based on the two exciplexes are also discussed.
NASA Astrophysics Data System (ADS)
Sun, Mingling; Kubota, Takahide; Takahashi, Shigeki; Kawato, Yoshiaki; Sonobe, Yoshiaki; Takanashi, Koki
2018-05-01
Buffer layer dependence of tunnel magnetoresistance (TMR) effects was investigated in Co2Fe0.4Mn0.6Si (CFMS)/MgO/Co50Fe50 magnetic tunnel junctions (MTJs). Pd, Ru and Cr were selected for the buffer layer materials, and MTJs with three different CFMS thicknesses (30, 5, and 0.8 nm) were fabricated. A maximum TMR ratio of 136% was observed in the Ru buffer layer sample with a 30-nm-thick CFMS layer. TMR ratios drastically degraded for the CFMS thickness of 0.8 nm, and the values were 26% for Cr buffer layer and less than 1% for Pd and Ru buffer layers. From the annealing temperature dependence of the TMR ratios, amounts of interdiffusion and effects from the lattice mismatch were discussed.
Strain engineering in epitaxial Ge1- x Sn x : a path towards low-defect and high Sn-content layers
NASA Astrophysics Data System (ADS)
Margetis, Joe; Yu, Shui-Qing; Bhargava, Nupur; Li, Baohua; Du, Wei; Tolle, John
2017-12-01
The plastic strain relaxation of CVD-grown Ge1-x Sn x layers was investigated in x = 0.09 samples with thicknesses of 152, 180, 257, 570, and 865 nm. X-ray diffraction-reciprocal space mapping was used to determine the strain, composition, and the nature of defects in each layer. Secondary ion mass spectrometry was used to examine the evolution of the compositional profile. These results indicate that growth beyond the critical thickness results in the spontaneous formation of a relaxed and highly defective 9% Sn layer followed by a low defect 12% Sn secondary layer. We find that this growth method can be used to engineer thick, strain-relaxed, and low defect density layers. Furthermore we utilize this strain-dependent Sn incorporation behavior to achieve Sn compositions of 17.5%. Photoluminesence of these layers produces light emission at 3.1 μm.
New Martian climate constraints from radar reflectivity within the north polar layered deposits
NASA Astrophysics Data System (ADS)
Lalich, D. E.; Holt, J. W.
2017-01-01
The north polar layered deposits (NPLD) of Mars represent a global climate record reaching back millions of years, potentially recorded in visible layers and radar reflectors. However, little is known of the specific link between those layers, reflectors, and the global climate. To test the hypothesis that reflectors are caused by thick and indurated layers known as "marker beds," the reflectivity of three reflectors was measured, mapped, and compared to a reflectivity model. The measured reflectivities match the model and show a strong sensitivity to layer thickness, implying that radar reflectivity may be used as a proxy for short-term accumulation patterns and that regional climate plays a strong role in layer thickness variations. Comparisons to an orbitally forced NPLD accumulation model show a strong correlation with predicted marker bed formation, but dust content is higher than expected, implying a stronger role for dust in Mars polar climate than previously thought.
Determination of layer ordering using sliding-window Fourier transform of x-ray reflectivity data
NASA Astrophysics Data System (ADS)
Smigiel, E.; Knoll, A.; Broll, N.; Cornet, A.
1998-01-01
X-ray reflectometry allows the determination of the thickness, density and roughness of thin layers on a substrate from several Angstroms to some hundred nanometres. The thickness is determined by simulation with trial-and-error methods after extracting initial values of the layer thicknesses from the result of a classical Fast Fourier Transform (FFT) of the reflectivity data. However, the order information of the layers is lost during classical FFT. The order of the layers has then to be known a priori. In this paper, it will be shown that the order of the layers can be obtained by a sliding-window Fourier transform, the so-called Gabor representation. This joint time-frequency analysis allows the direct determination of the order of the layers and, therefore, the use of a more appropriate starting model for refining simulations. A simulated and a measured example show the interest of this method.
Temperature effects on the ultrasonic separation of fat from natural whole milk.
Leong, Thomas; Juliano, Pablo; Johansson, Linda; Mawson, Raymond; McArthur, Sally L; Manasseh, Richard
2014-11-01
This study showed that temperature influences the rate of separation of fat from natural whole milk during application of ultrasonic standing waves. In this study, natural whole milk was sonicated at 600kHz (583W/L) or 1MHz (311W/L) with a starting bulk temperature of 5, 25, or 40°C. Comparisons on separation efficiency were performed with and without sonication. Sonication using 1MHz for 5min at 25°C was shown to be more effective for fat separation than the other conditions tested with and without ultrasound, resulting in a relative change from 3.5±0.06% (w/v) fat initially, of -52.3±2.3% (reduction to 1.6±0.07% (w/v) fat) in the skimmed milk layer and 184.8±33.2% (increase to 9.9±1.0% (w/v) fat) in the top layer, at an average skimming rate of ∼5g fat/min. A shift in the volume weighted mean diameter (D[4,3]) of the milk samples obtained from the top and bottom of between 8% and 10% relative to an initial sample D[4,3] value of 4.5±0.06μm was also achieved under these conditions. In general, faster fat separation was seen in natural milk when natural creaming occurred at room temperature and this separation trend was enhanced after the application of high frequency ultrasound. Copyright © 2014 Elsevier B.V. All rights reserved.
Krishnan, K.M.
1994-12-20
A ferromagnetic [delta]-Mn[sub 1[minus]x]Ga[sub x] thin film having perpendicular anisotropy is described which comprises: (a) a GaAs substrate, (b) a layer of undoped GaAs overlying said substrate and bonded thereto having a thickness ranging from about 50 to about 100 nanometers, (c) a layer of [delta]-Mn[sub 1[minus]x]Ga[sub x] overlying said layer of undoped GaAs and bonded thereto having a thickness ranging from about 20 to about 30 nanometers, and (d) a layer of GaAs overlying said layer of [delta]-Mn[sub 1[minus]x]Ga[sub x] and bonded thereto having a thickness ranging from about 2 to about 5 nanometers, wherein x is 0.4[+-]0.05. 7 figures.
Protein deposition on field-emitter tips and its removal by UV radiation
NASA Astrophysics Data System (ADS)
Panitz, J. A.; Giaever, I.
1980-07-01
Protein deposition on field-emitter tips has been examined using Transmission Electron Microscopy to view the protein coated tip profile. A single layer of adsorbed protein is barely if at all detectable, but double and triple layers produced by the immunologic reaction can be directly observed. As a result, the thickness and morphology of antigen-antibody layers has been directly observed for the first time. Tips exposed first to Bovine Serum Albumin (BSA) and then to anti-BSA rabbit serum are covered with a reasonably uniform, double protein layer ≈130 Å thick. This layer can be built-up to a triple layer ≈275 Å thick by additional exposure to anti-rabbit IgG goat serum. Surface tension forces during the drying process which follows protein deposition appear to affect the thickness and morphology of the protein layers. The oxidation and subsequent change in the morphology of a protein layer exposed to ultraviolet radiation has also been observed using TEM. The destruction of a triple protein layer at a rate of ≈0.5 Å/s is observed for tungsten tips exposed to ≈6 W of UV radiation from a high-pressure mercury arc in laboratory ambient. These results are compared to those obtained from a simple, visual test for protein layer adsorption in which submonolayer coverages of protein can be detected with the unaided eye.
Physical Limitations of Phosphor layer thickness and concentration for White LEDs.
Tan, Cher Ming; Singh, Preetpal; Zhao, Wenyu; Kuo, Hao-Chung
2018-02-05
Increasing phosphor layer thickness and concentration can enhance the lumen flux of white LED (W-LED). In this work, we found that increasing the phosphor layer thickness and concentration can increase its temperature, and there is also a maximum thickness and concentration beyond which their increase will not lead to lumen increase, but only temperature increase. Higher thickness and higher concentration also results in warm light instead of White light. The maximum thickness and concentration are found to be limited by the scattering of light rays with higher % decrease of blue light rays than the yellow light rays. The results obtained in this work can also be used to compute the temperature and thermo-mechanical stress distribution of an encapsulated LED, demonstrating its usefulness to the design of encapsulated LED packages. Simulation software like ANSYS and TracePro are used extensively to verify the root cause mechanisms.
NASA Astrophysics Data System (ADS)
Shi, Xiangyang; Wu, Yuanyuan; Wang, Ding; Su, Juan; Liu, Jie; Yang, Wenxian; Xiao, Meng; Tan, Wei; Lu, Shulong; Zhang, Jian
2017-12-01
We demonstrate both theoretically and experimentally that the power density of resonant tunneling diode (RTD) can be enhanced by optimizing emitter spacer layer thickness, in addition to reducing barrier thickness. Compared to the widely used epitaxial structure with ultrathin emitter spacer layer thickness, appropriate increasing the thickness will increase the voltage drop in accumulation region, leading to larger voltage widths of negative differential resistance region. By measuring J-V characteristics, the specific contact resistivity, and the self-capacitance, we theoretically analyze the maximum output power of the fabricated RTDs. It shows that the optimized In0.8Ga0.2As/AlAs RTD with 20 nm emitter spacer thickness and 5 μm2 mesa area theoretically possesses the capability to reach 3.1 mW at 300 GHz and 1.8 mW at 600 GHz.
Characterization of crystal structure features of a SIMOX substrate
NASA Astrophysics Data System (ADS)
Eidelman, K. B.; Shcherbachev, K. D.; Tabachkova, N. Yu.; Podgornii, D. A.; Mordkovich, V. N.
2015-12-01
The SIMOX commercial sample (Ibis corp.) was investigated by a high-resolution X-ray diffraction (HRXRD), a high-resolution transmission electron microscopy (HRTEM) and an Auger electron spectroscopy (AES) to determine its actual parameters (the thickness of the top Si and a continuous buried oxide layer (BOX), the crystalline quality of the top Si layer). Under used implantation conditions, the thickness of the top Si and BOX layers was 200 nm and 400 nm correspondingly. XRD intensity distribution near Si(0 0 4) reciprocal lattice point was investigated. According to the oscillation period of the diffraction reflection curve defined thickness of the overtop silicon layer (220 ± 2) nm. HRTEM determined the thickness of the oxide layer (360 nm) and revealed the presence of Si islands with a thickness of 30-40 nm and a length from 30 to 100 nm in the BOX layer nearby "BOX-Si substrate" interface. The Si islands are faceted by (1 1 1) and (0 0 1) faces. No defects were revealed in these islands. The signal from Si, which corresponds to the particles in an amorphous BOX matrix, was revealed by AES in the depth profiles. Amount of Si single crystal phase at the depth, where the particles are deposited, is about 10-20%.
NASA Astrophysics Data System (ADS)
Mimila-Arroyo, J.; Bland, S.; Barbé, M.
2002-05-01
The reactivation kinetics of the acceptor behavior of carbon, its dependence on dopant precursors, doping level, layer thickness, and annealing temperature, as well as the behavior of carbon-hydrogen complexes in GaAs grown by metalorganic chemical vapor deposition are studied. Independent of the carbon source, in the "as grown" material, systematically carbon hydrogen complexes are present and the hole concentration is lower than the corresponding carbon concentration. The carbon reactivation kinetics was achieved by ex situ rapid thermal annealing through a series of multistage annealing experiments and assessed at each annealing stage by infrared absorption, hydrogen secondary ion mass spectroscopy profiling, and hole concentration measurements. Carbon reactivation occurs solely by the debonding of hydrogen from the isolated carbon acceptor and its out-diffusion from the sample. The carbon reactivation kinetics can be treated as a first order one with an activation energy, Ea=1.42±0.01 eV, independent of doping precursors, doping level, and layer thickness. The reactivation constant results to decrease as doping level and layer thickness increase. An empirical formula has been obtained that allows one to calculate the reactivation constant as a function of the carbon doping, layer thickness, and annealing temperature, allowing one to determine the optimal carbon reactivation conditions for any C:GaAs layer.
Investigation of Electrical and Optical Properties of Highly Transparent TCO/Ag/TCO Multilayer.
Kim, Sunbo; Lee, Jaehyeong; Dao, Vinh Ai; Ahn, Shihyun; Hussain, Shahzada Qamar; Park, Jinjoo; Jung, Junhee; Lee, Chan; Song, Bong-Shik; Choi, Byoungdeog; Lee, Youn-Jung; Iftiquar, S M; Yi, Junsin
2015-03-01
Transparent conductive oxides (TCOs) have been widely used as transparent electrodes for opto-electronic devices, such as solar cells, flat-panel displays, and light-emitting diodes, because of their unique characteristics of high optical transmittance and low electrical resistivity. Among various TCO materials, zinc oxide based films have recently received much attention because they have advantages over commonly used indium and tin-based oxide films. Most TCO films, however, exhibit valleys of transmittance in the wavelength range of 550-700 nm, lowering the average transmittance in the visible region and decreasing short-circuit current (Isc) of solar cells. A TCO/Ag/TCO multi-layer structure has emerged as an attractive alternative because it provides optical characteristics without the valley of transmittance compared with a 100-nm-thick single-layer TCO. In this article, we report the electrical, optical and surface properties of TCO/Ag/TCO. These multi-layers were deposited at room temperature with various Ag film thicknesses from 5 to 15 nm while the thickness of TCO thin film was fixed at 40 nm. The TCO/Ag/TCO multi-layer with a 10-nm-thick Ag film showed optimum transmittance in the visible (400-800 nm) wavelength region. These multi-layer structures have advantages over TCO layers of the same thickness.
Effects of the PPy layer thickness on Co-PPy composite films
NASA Astrophysics Data System (ADS)
Haciismailoglu, Murside
2015-11-01
Co-PPy composite films were electrodeposited on ITO substrate from two different solutions potentiostatically. Firstly, the PPy layers with the thicknesses changing from 20 to 5000 nm were produced on ITO. Then Co was electrodeposited on these PPy/ITO substrates with a charge density of 1000 mC cm-2. The electrochemical properties were investigated by the current density-time transients and the variation of the elapsed time for the Co deposition depending on the PPy layer thickness. X-ray photoelectron (XPS) spectra indicated the presence of both Co metal and its oxides on the surface. The weak reflections of the Co3O4, CoO and hcp Co were detected by the X-ray diffraction (XRD) technique. According to scanning electron microscopy (SEM) images, the thickness of the PPy layer strongly affects the Co nucleation. The composite films with the PPy layer thinner than 200 nm and thicker than 2000 nm have an isotropic magnetic behavior due to the symmetrical crystal field. The composite films with the PPy layer thicknesses between 200 and 2000 nm have an anisotropic magnetic behavior attributable to the deterioration of this symmetrical crystal field by the PPy bubbles on the surface. All films are hard magnetic material, since the coercivities are larger than 125 Oe.
XPS-XRF hybrid metrology enabling FDSOI process
NASA Astrophysics Data System (ADS)
Hossain, Mainul; Subramanian, Ganesh; Triyoso, Dina; Wahl, Jeremy; Mcardle, Timothy; Vaid, Alok; Bello, A. F.; Lee, Wei Ti; Klare, Mark; Kwan, Michael; Pois, Heath; Wang, Ying; Larson, Tom
2016-03-01
Planar fully-depleted silicon-on-insulator (FDSOI) technology potentially offers comparable transistor performance as FinFETs. pFET FDOSI devices are based on a silicon germanium (cSiGe) layer on top of a buried oxide (BOX). Ndoped interfacial layer (IL), high-k (HfO2) layer and the metal gate stacks are then successively built on top of the SiGe layer. In-line metrology is critical in precisely monitoring the thickness and composition of the gate stack and associated underlying layers in order to achieve desired process control. However, any single in-line metrology technique is insufficient to obtain the thickness of IL, high-k, cSiGe layers in addition to Ge% and N-dose in one single measurement. A hybrid approach is therefore needed that combines the capabilities of more than one measurement technique to extract multiple parameters in a given film stack. This paper will discuss the approaches, challenges, and results associated with the first-in-industry implementation of XPS-XRF hybrid metrology for simultaneous detection of high-k thickness, IL thickness, N-dose, cSiGe thickness and %Ge, all in one signal measurement on a FDSOI substrate in a manufacturing fab. Strong correlation to electrical data for one or more of these measured parameters will also be presented, establishing the reliability of this technique.
Anglim, Breffini; Farah, Nadine; O'Connor, Clare; Daly, Niamh; Kennelly, Mairead M; Turner, Michael J
2017-07-01
Maternal obesity is an emerging challenge in contemporary obstetrics. To date there has been no study analysing the relationship between specific maternal body composition measurements and foetal soft-tissue measurements. The aim of this study was to determine whether measurement of maternal body composition at booking predicts foetal soft-tissue trajectories in the third trimester. We analysed the relationship between foetal thigh in the third trimester and both maternal BMI and body composition using the Tanita digital scales in the first trimester. Foetal subcutaneous thigh tissue measurements were obtained at intervals of 28, 32 and 36 weeks of gestation. A total of 160 women were identified. There was a direct correlation between MTST at 36 weeks and BMI (p = .002). There was a positive correlation between MTST at 36 weeks and leg fat mass (p = .13) and leg fat free mass (p = .013). There was a positive correlation between arm fat free mass and MTST at 36 weeks. We showed there is an association between maternal fat distribution and foetal subcutaneous thigh tissue measurements. MTST may be more useful in determining if a child is at risk of macrosomia. Impact statement Previous studies have suggested that maternal obesity programmes intrauterine foetal adiposity and growth. The aim of this study was to examine the relationship in a high-risk obstetric population between measurements of maternal body composition in early pregnancy and the assessment of foetal adiposity in the third trimester using serial ultrasound measurements of mid-thigh soft-tissue thickness. BMI is only a surrogate measurement of fat and does not measure fat distribution. Our study shows the distribution of both maternal fat and fat-free mass in early pregnancy may be positively associated with foetal soft-tissue measurements in the third trimester. Maternal arthropometric measurements other than BMI may help predict babies at risk of macrosomia and neonatal adiposity.
Nikezic, D; Shahmohammadi Beni, Mehrdad; Krstic, D; Yu, K N
2016-01-01
Monte Carlo method has been used to determine the efficiency for proton production and to study the energy and angular distributions of the generated protons. The ENDF library of cross sections is used to simulate the interactions between the neutrons and the atoms in a polyethylene (PE) layer, while the ranges of protons with different energies in PE are determined using the Stopping and Range of Ions in Matter (SRIM) computer code. The efficiency of proton production increases with the PE layer thickness. However the proton escaping from a certain polyethylene volume is highly dependent on the neutron energy and target thickness, except for a very thin PE layer. The energy and angular distributions of protons are also estimated in the present paper, showing that, for the range of energy and thickness considered, the proton flux escaping is dependent on the PE layer thickness, with the presence of an optimal thickness for a fixed primary neutron energy.
Impact of thickness on the structural properties of high tin content GeSn layers
NASA Astrophysics Data System (ADS)
Aubin, J.; Hartmann, J. M.; Gassenq, A.; Milord, L.; Pauc, N.; Reboud, V.; Calvo, V.
2017-09-01
We have grown various thicknesses of GeSn layers in a 200 mm industrial Reduced Pressure - Chemical Vapor Deposition cluster tool using digermane (Ge2H6) and tin tetrachloride (SnCl4). The growth pressure (100 Torr) and the F(Ge2H6)/F(SnCl4) mass-flow ratio were kept constant, and incorporation of tin in the range of 10-15% was achieved with a reduction in temperature: 325 °C for 10% to 301 °C for 15% of Sn. The layers were grown on 2.5 μm thick Ge Strain Relaxed Buffers, themselves on Si(0 0 1) substrates. We used X-ray Diffraction, Atomic Force Microscopy, Raman spectroscopy and Scanning Electron Microscopy to measure the Sn concentration, the strain state, the surface roughness and thickness as a function of growth duration. A dramatic degradation of the film was seen when the Sn concentration and layer thickness were too high resulting in rough/milky surfaces and significant Sn segregation.
Nikezic, D.; Shahmohammadi Beni, Mehrdad; Krstic, D.; Yu, K. N.
2016-01-01
Monte Carlo method has been used to determine the efficiency for proton production and to study the energy and angular distributions of the generated protons. The ENDF library of cross sections is used to simulate the interactions between the neutrons and the atoms in a polyethylene (PE) layer, while the ranges of protons with different energies in PE are determined using the Stopping and Range of Ions in Matter (SRIM) computer code. The efficiency of proton production increases with the PE layer thickness. However the proton escaping from a certain polyethylene volume is highly dependent on the neutron energy and target thickness, except for a very thin PE layer. The energy and angular distributions of protons are also estimated in the present paper, showing that, for the range of energy and thickness considered, the proton flux escaping is dependent on the PE layer thickness, with the presence of an optimal thickness for a fixed primary neutron energy. PMID:27362656
NASA Astrophysics Data System (ADS)
Nie, Qu-yang; Zhang, Fang-hui
2018-05-01
The inverted bottom-emitting organic light-emitting devices (IBOLEDs) were prepared, with the structure of ITO/Al ( x nm)/LiF (1 nm)/Bphen (40 nm)/CBP: GIr1 (14%):R-4b (2%) (10 nm)/BCP (3 nm)/CBP:GIr1 (14%):R-4b (2%) (20 nm)/TCTA (10 nm)/NPB (40 nm)/MoO3 (40 nm)/Al (100 nm), where the thickness of electron injection layer Al ( x) are 0 nm, 2 nm, 3 nm, 4 nm and 5 nm, respectively. In this paper, the electron injection condition and luminance properties of inverted devices were investigated by changing the thickness of Al layer in Al/LiF compound thin film. It turns out that the introduction of Al layer can improve electron injection of the devices dramatically. Furthermore, the device exerts lower driving voltage and higher current efficiency when the thickness of electron injection Al layer is 3 nm. For example, the current efficiency of the device with 3-nm-thick Al layer reaches 19.75 cd·A-1 when driving voltage is 7 V, which is 1.24, 1.17 and 17.03 times larger than those of the devices with 2 nm, 4 nm and 5 nm Al layer, respectively. The device property reaches up to the level of corresponding conventional device. In addition, all inverted devices with electron injection Al layer show superior stability of color coordinate due to the adoption of co-evaporation emitting layer and BCP spacer-layer, and the color coordinate of the inverted device with 3-nm-thick Al layer only changes from (0.580 6, 0.405 6) to (0.532 8, 0.436 3) when driving voltage increases from 6 V to 10 V.
NASA Technical Reports Server (NTRS)
Dickerson, G. E. (Inventor)
1977-01-01
A process was developed for preparing relatively thick composite laminate structure wherein thin layers of prepreg tapes are assembled, these thin layers are cut into strips that are partially cured, and stacked into the desired thickness with uncured prepreg disposed between each layer of strips. The formed laminate is finally cured and thereafter machined to the desired final dimensions.
NASA Astrophysics Data System (ADS)
Ortega-Feliu, I.; Ager, F. J.; Roldán, C.; Ferretti, M.; Juanes, D.; Scrivano, S.; Respaldiza, M. A.; Ferrazza, L.; Traver, I.; Grilli, M. L.
2017-09-01
This work presents a detailed study of a series of silver plates gilded via electroplating techniques in which the characteristics of the coating gold layers are investigated as a function of the electroplating variables (voltage, time, anode surface and temperature). Some reference samples were coated by radio frequency sputtering in order to compare gold layer homogeneity and effective density. Surface analysis was performed by means of atomic and nuclear techniques (SEM-EDX, EDXRF, PIXE and RBS) to obtain information about thickness, homogeneity, effective density, profile concentration of the gold layers and Au-Ag diffusion profiles. The gold layer thickness obtained by PIXE and EDXRF is consistent with the thickness obtained by means of RBS depth profiling. Electroplated gold mass thickness increases with electroplating time, anode area and voltage. However, electrodeposited samples present rough interfaces and gold layer effective densities lower than the nominal density of Au (19.3 g/cm3), whereas sputtering produces uniform layers with nominal density. These analyses provide valuable information to historians and curators and can help the restoration process of gold-plated silver objects.
High resolution thickness measurements of ultrathin Si:P monolayers using weak localization
NASA Astrophysics Data System (ADS)
Hagmann, Joseph A.; Wang, Xiqiao; Namboodiri, Pradeep; Wyrick, Jonathan; Murray, Roy; Stewart, M. D.; Silver, Richard M.; Richter, Curt A.
2018-01-01
The key building blocks for the fabrication of devices based on the deterministic placement of dopants in silicon using scanning tunneling microscopy (STM) hydrogen lithography are the formation of well-defined dopant delta-layers and the overgrowth of high quality crystalline Si. To develop these capabilities, it is of critical importance to quantify dopant movement in the sub-nanometer regime. To this end, we investigate Si:P delta-layer samples produced by fully exposing a Si surface to PH3 prior to Si encapsulation with dramatically different levels of dopant confinement. We examine the effect of delta layer confinement on the weak localization signal in parallel and perpendicular magnetic fields and extract the delta-layer thickness from fits to the Hikami-Larkin-Nagaoka equation. We find good agreement with secondary ion mass spectroscopy measurements and demonstrate the applicability of this method in the sub-nanometer thickness regime. Our analysis serves as detailed instruction for the determination of the conducting layer thickness of a Si:P delta-layer by means of a high-throughput, nondestructive electrical transport measurement.
Dependence of seed layer thickness on sensitivity of nano-ZnO cholesterol biosensor
NASA Astrophysics Data System (ADS)
Lu, Yang-Ming; Wang, Po-Chin; Tang, Jian-Fu; Chu, Sheng-Yuan
2017-01-01
The anemone-like ZnO nanostructures have been synthesized by hydrothermal method and were further adsorbed immobilized cholesterol oxidase (ChOx) as a nano-biosensor. In this study, the sensitivity of biosensor were improved by varying the thickness of the ZnO seed layer. The SEM analysis showed changes in thickness of seed layer will not affect the morphologies of anemone-like ZnO nanostructures. The X-ray Diffraction patterns showed that the (002) plane of anemone-like ZnO grown on various thickness of the seed layer was more prouded than other crystal plane. Abioelectrode (ChOx/ZnO/ITO/glass) grown on the 30nm of ZnO seed layer with high sensitivity of 57.533μAmM-1cm-2 (1.488 μA (mg/dl) -1cm-2), a wide sensitive range from 25 to 500 mg/dl. It is concluded that the thinner sputtered ZnO seed layer for growing anemone-like ZnO nanostructure can effectively improve the sensitivity of the ZnO biosensor.
Ultrasound-based measurement of liquid-layer thickness: A novel time-domain approach
NASA Astrophysics Data System (ADS)
Praher, Bernhard; Steinbichler, Georg
2017-01-01
Measuring the thickness of a thin liquid layer between two solid materials is important when the adequate separation of metallic parts by a lubricant film (e.g., in bearings or mechanical seals) is to be assessed. The challenge in using ultrasound-based systems for such measurements is that the signal from the liquid layer is a superposition of multiple reflections. We have developed an algorithm for reconstructing this superimposed signal in the time domain. By comparing simulated and measured signals, the time-of-flight of the ultrasonic pulse in a layer can be estimated. With the longitudinal sound velocity known, the layer thickness can then be calculated. In laboratory measurements, we validate successfully (maximum relative error 4.9%) our algorithm for layer thicknesses ranging from 30 μm to 200 μm. Furthermore, we tested our method in the high-temperature environment of polymer processing by measuring the clearance between screw and barrel in the plasticisation unit of an injection moulding machine. The results of such measurements can indicate (i) the wear status of the tribo-mechanical screw-barrel system and (ii) unsuitable process conditions.
NASA Astrophysics Data System (ADS)
Feinaeugle, Matthias; Horak, Peter; Sones, Collin L.; Lippert, Thomas; Eason, Rob W.
2014-09-01
In this study, we investigate both experimentally and numerically laser-induced forward transfer (LIFT) of thin films to determine the role of a thin polymer layer coating the receiver with the aim of modifying the rate of deceleration and reduction of material stress preventing intact material transfer. A numerical model of the impact phase during LIFT shows that such a layer reduces the modelled stress. The evolution of stress within the transferred deposit and the substrate as a function of the thickness of the polymer layer, the transfer velocity and the elastic properties of the polymer are evaluated. The functionality of the polymer layer is verified experimentally by LIFT printing intact 1- m-thick bismuth telluride films and polymeric light-emitting diode pads onto a layer of 12-m-thick polydimethylsiloxane and 50-nm-thick poly(3,4-ethylenedioxythiophene) blended with poly(styrenesulfonate) (PEDOT:PSS), respectively. Furthermore, it is demonstrated experimentally that the introduction of such a compliant layer improves adhesion between the deposit and its substrate.
A method of detection to the grinding wheel layer thickness based on computer vision
NASA Astrophysics Data System (ADS)
Ji, Yuchen; Fu, Luhua; Yang, Dujuan; Wang, Lei; Liu, Changjie; Wang, Zhong
2018-01-01
This paper proposed a method of detection to the grinding wheel layer thickness based on computer vision. A camera is used to capture images of grinding wheel layer on the whole circle. Forward lighting and back lighting are used to enables a clear image to be acquired. Image processing is then executed on the images captured, which consists of image preprocessing, binarization and subpixel subdivision. The aim of binarization is to help the location of a chord and the corresponding ring width. After subpixel subdivision, the thickness of the grinding layer can be calculated finally. Compared with methods usually used to detect grinding wheel wear, method in this paper can directly and quickly get the information of thickness. Also, the eccentric error and the error of pixel equivalent are discussed in this paper.
Thick adherent dielectric films on plastic substrates and method for depositing same
Wickboldt, Paul; Ellingboe, Albert R.; Theiss, Steven D.; Smith, Patrick M.
2002-01-01
Thick adherent dielectric films deposited on plastic substrates for use as a thermal barrier layer to protect the plastic substrates from high temperatures which, for example, occur during laser annealing of layers subsequently deposited on the dielectric films. It is desirable that the barrier layer has properties including: a thickness of 1 .mu.m or greater, adheres to a plastic substrate, does not lift-off when cycled in temperature, has few or no cracks and does not crack when subjected to bending, resistant to lift-off when submersed in fluids, electrically insulating and preferably transparent. The thick barrier layer may be composed, for example, of a variety of dielectrics and certain metal oxides, and may be deposited on a variety of plastic substrates by various known deposition techniques. The key to the method of forming the thick barrier layer on the plastic substrate is maintaining the substrate cool during deposition of the barrier layer. Cooling of the substrate maybe accomplished by the use of a cooling chuck on which the plastic substrate is positioned, and by directing cooling gas, such as He, Ar and N.sub.2, between the plastic substrate and the cooling chucks. Thick adherent dielectric films up to about 5 .mu.m have been deposited on plastic substrates which include the above-referenced properties, and which enable the plastic substrates to withstand laser processing temperatures applied to materials deposited on the dielectric films.
NASA Astrophysics Data System (ADS)
Xu, Zhihao; Gotoh, Kazuhiro; Deng, Tianguo; Sato, Takuma; Takabe, Ryota; Toko, Kaoru; Usami, Noritaka; Suemasu, Takashi
2018-05-01
We studied the surface passivation effect of hydrogenated amorphous silicon (a-Si:H) layers on BaSi2 films. a-Si:H was formed by an electron-beam evaporation of Si, and a supply of atomic hydrogen using radio-frequency plasma. Surface passivation effect was first investigated on a conventional n-Si(111) substrate by capping with 20 nm-thick a-Si:H layers, and next on a 0.5 μm-thick BaSi2 film on Si(111) by molecular beam epitaxy. The internal quantum efficiency distinctly increased by 4 times in a wide wavelength range for sample capped in situ with a 3 nm-thick a-Si:H layer compared to those capped with a pure a-Si layer.
Magnetic properties of Pr-Fe-B thick-film magnets deposited on Si substrates with glass buffer layer
NASA Astrophysics Data System (ADS)
Nakano, M.; Kurosaki, A.; Kondo, H.; Shimizu, D.; Yamaguchi, Y.; Yamashita, A.; Yanai, T.; Fukunaga, H.
2018-05-01
In order to improve the magnetic properties of PLD-made Pr-Fe-B thick-film magnets deposited on Si substrates, an adoption of a glass buffer layer was carried out. The glass layer could be fabricated under the deposition rate of approximately 70 μm/h on a Si substrate using a Nd-YAG pulse laser in the vacuum atmosphere. The use of the layer enabled us to reduce the Pr content without a mechanical destruction and enhance (BH)max value by approximately 20 kJ/m3 compared with the average value of non-buffer layered Pr-Fe-B films with almost the same thickness. It is also considered that the layer is also effective to apply a micro magnetization to the films deposited on Si ones.
Evaluation of Retinal Changes in Progressive Supranuclear Palsy and Parkinson Disease.
Gulmez Sevim, Duygu; Unlu, Metin; Gultekin, Murat; Karaca, Cagatay; Mirza, Meral; Mirza, Galip Ertugrul
2018-06-01
Differentiating Parkinson disease (PD) from progressive supranuclear palsy (PSP) can be challenging early in the clinical course. The aim of our study was to see if specific retinal changes could serve as a distinguishing feature. We used spectral domain optical coherence tomography (SD-OCT) with automatic segmentation to measure peripapillary nerve fiber layer thickness and the thickness and volume of retinal layers at the macula. Thicknesses of superior peripapillary retinal nerve fiber layer (pRNFL), macular ganglion cell layer, inner plexiform layer, inner nuclear layer, and macular volume were more affected in PSP compared with PD (P < 0.05). Thicker inferotemporal pRNFL and lower macular volume were detected in levodopa users compared with nonusers in patients with PD. PD and PSP are associated with distinct changes in retinal morphology, which can be assessed with SD-OCT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sokolov, V I; Glebov, V N; Malyutin, A M
2015-09-30
A method based on resonant excitation of waveguide modes with a prism coupler is proposed for measuring the thickness and refractive index of thin-film layers in multilayer dielectric structures. The peculiarities of reflection of TE- and TM-polarised light beams from a structure comprising eleven alternating layers of zinc sulfide (ZnS) and magnesium barium fluoride (MgBaF{sub 4}), whose thicknesses are much less than the wavelength of light, are investigated. Using the mathematical model developed, we have calculated the coefficients of reflection of collimated TE and TM light beams from a multilayer structure and determined the optical constants and thicknesses of themore » structure layers. The refractive indices of the layers, obtained for TE and TM polarisation of incident light, are in good agreement. The thicknesses of ZnS and MgBaF{sub 4} layers, found for different polarisations, coincide with an accuracy of ±1%. Thus, we have demonstrated for the first time that the prism-coupling technique allows one to determine the optical properties of thin-film structures when the number of layers in the structure exceeds ten layers. (integrated optics)« less
NASA Technical Reports Server (NTRS)
Croke, E. T.; Wang, K. L.; Heyd, A. R.; Alterovitz, S. A.; Lee, C. H.
1996-01-01
Variable angle spectroscopic ellipsometry (VASE) has been used to characterize Si(x)Ge(1-x)/Ge superlattices (SLs) grown on Ge substrates and thick Si(x)Ge(1-x)/Ge heterostructures grown on Si substrates. Our VASE analysis yielded the thicknesses and alloy compositions of all layers within the optical penetration depth of the surface. In addition, strain effects were observed in the VASE results for layers under both compressive and tensile strain. Results for the SL structures were found to be in close agreement with high resolution x-ray diffraction measurements made on the same samples. The VASE analysis has been upgraded to characterize linearly graded Si(x)Ge(1-x) buffer layers. The algorithm has been used to determine the total thickness of the buffer layer along with the start and end alloy composition by breaking the total thickness into many (typically more than 20) equal layers. Our ellipsometric results for 1 (mu)m buffer layers graded in the ranges 0.7 less than or = x less than or = 1.0, and 0.5 less than or = x less than or = 1.0 are presented, and compare favorably with the nominal values.
Perpendicular magnetic tunnel junctions with Mn-modified ultrathin MnGa layer
NASA Astrophysics Data System (ADS)
Suzuki, K. Z.; Miura, Y.; Ranjbar, R.; Bainsla, L.; Ono, A.; Sasaki, Y.; Mizukami, S.
2018-02-01
Perpendicular magnetic tunnel junctions (p-MTJs) with a MgO barrier and a 1-nm-thick MnGa electrode were investigated by inserting several monolayers (MLs) of Mn. The tunnel magnetoresistance (TMR) ratio systematically increased when increasing the Mn layer thickness with a maximum of 18 (38.4)% at 300 (5) K for a Mn layer thickness of 0.6-0.8 nm. This ratio is five times higher compared to that without the Mn layer. The perpendicular magnetic anisotropy (PMA) field and the PMA constant of the ultrathin MnGa layer also increased up to 62-90 kOe and 6.2-11.3 Merg/cm3, respectively, with an increase in the Mn interlayer thickness, even for the ultrathin regime of the MnGa layer. For p-MTJs showing a high TMR and PMA, electron microscopy indicated the presence of 3-4 MLs of Mn at the MnGa/MgO interface; thus, the Mn modification enhanced the TMR as well as improved the PMA. This may be a promising finding to develop a Mn-based free layer for spin-transfer-torque devices for high-recording-density magnetoresistive random access memory and a sub-THz oscillator/detector.
Cense, B; Chen, T C; de Boer, J F
2006-01-01
Thinning of the retinal nerve fiber layer and changes in retinal nerve fiber layer birefringence may both precede clinically detectable glaucomatous vision loss. We present in vivo thickness and depth-resolved birefringence measurements of the human retinal nerve fiber layer (RNFL) by use of polarization-sensitive optical coherence tomography (PS-OCT). Using a fiber-based PS-OCT setup real-time images of the human retina in vivo were recorded, co-registered with retinal video images of the location of PS-OCT scans. PS-OCT scans around the optic nerve head (ONH) of two healthy young volunteers were made using 10 concentric circles of increasing radius. Both the mean retinal nerve fiber layer thickness and mean retinal nerve fiber birefringence for each of 48 sectors on a circle were determined. The retinal nerve fiber layer thickness and birefringence varied as a function of sector around the ONH. Measured double pass phase retardation per unit depth values around the ONH range between 0.10 and 0.35 degrees/microm. The retinal nerve fiber layer becomes thinner with increasing distance from the ONH. In contrast, the birefringence does not vary significantly with increasing distance from the ONH.