Sample records for fcap facilities ranged

  1. Monitoring and Evaluation of Yearling Fall Chinook Salmon (Oncorhynchus tshawytscha) Released from Acclimation Facilities Upstream of Lower Granite Dam; 2003 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rocklage, Stephen J.

    The Nez Perce Tribe, in cooperation with the U.S. Fish and Wildlife Service and Washington Department of Fish and Wildlife, conducted monitoring and evaluation studies on Lyons Ferry Hatchery reared yearling fall Chinook salmon Oncorhynchus tshawytscha that were acclimated and released at three Fall Chinook Acclimation Project (FCAP) sites upstream of Lower Granite Dam in 2003. This was the eighth year of a long-term project to supplement natural spawning populations of Snake River stock fall Chinook salmon upstream of Lower Granite Dam. The 437,633 yearlings released from the Fall Chinook Acclimation Project facilities were short of the 450,000 fish quota.more » We use Passive Integrated Transponder (PIT) tag technology to monitor the primary performance measures of survival to mainstem dams and migration timing. We also monitor size, condition and tag/mark retention at release. We released 7,492 PIT tagged yearlings from Pittsburg Landing, 7,494 from Big Canyon and 2,497 from Captain John Rapids. Fish health sampling indicated that, overall, bacterial kidney disease levels at the acclimation facilities could be considered medium with 37-83% of the fish sampled rating medium to very high. Mean fork lengths (95% confidence interval) of the PIT tagged groups ranged from 153.7 mm (153.2-154.2 mm) at Captain John Rapids to 164.2 mm (163.9-164.5 mm) at Pittsburg Landing. Mean condition factors ranged from 1.06 at Lyons Ferry Hatchery to 1.22 at Captain John Rapids. Estimated survival (95% confidence interval) of PIT tagged yearlings from release to Lower Granite Dam ranged from 83.1% (80.7-85.5%) for Big Canyon to 91.7% (87.7-95.7%) for Captain John Rapids. Estimated survival from release to McNary Dam ranged from 59.9% (54.6-65.2%) for Big Canyon to 69.4% (60.5-78.4%) for Captain John Rapids. Median migration rates to Lower Granite Dam, based on all observations of PIT tagged yearlings from the FCAP facilities, ranged from 5.8 river kilometers per day (rkm/d) for Captain John Rapids to 16.2 rkm/d for Pittsburg Landing. Median migration rates to McNary Dam ranged from 11.7 rkm/d for Captain John Rapids to 17.6 rkm/d for Pittsburg Landing. Median travel times from the FCAP facilities were about 8-15 days to Lower Granite Dam and 22-27 days to McNary Dam. Median arrival dates at Lower Granite Dam, based on all observations of PIT tagged yearling groups from the FCAP facilities, ranged from April 23-25. Median arrival dates at McNary Dam for Pittsburg Landing, Big Canyon and Captain John Rapids groups ranged from May 4-10.« less

  2. Monitoring and Evaluation of Yearling Fall Chinook Salmon (Oncorhynchus tshawytscha) Released from Acclimation Facilities Upstream of Lower Granite Dam; 1999 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rocklage, Stephen J.; Kellar, Dale S.

    2005-07-01

    The Nez Perce Tribe, in cooperation with the U.S. Fish and Wildlife Service and Washington Department of Fish and Wildlife, conducted monitoring and evaluation studies on Lyons Ferry Hatchery reared yearling fall Chinook salmon Oncorhynchus tshawytscha that were acclimated and released at three Fall Chinook Acclimation Project (FCAP) sites upstream of Lower Granite Dam along with yearlings released on-station from Lyons Ferry Hatchery in 1999. This was the fourth year of a long-term project to supplement natural spawning populations of Snake River stock fall Chinook salmon upstream of Lower Granite Dam. The 453,117 yearlings released from the Fall Chinook Acclimationmore » Project facilities not only slightly exceeded the 450,000 fish quota, but a second release of 76,386 yearlings (hereafter called Surplus) were acclimated at the Big Canyon facility and released about two weeks after the primary releases. We use Passive Integrated Transponder (PIT) tag technology to monitor the primary performance measures of survival to mainstem dams and migration timing. We also monitor size, condition and tag/mark retention at release. We released 9,941 PIT tagged yearlings from Pittsburg Landing, 9,583 from Big Canyon, 2,511 Big Canyon Surplus and 2,494 from Captain John Rapids. The Washington Department of Fish and Wildlife released 983 PIT tagged yearlings from Lyons Ferry Hatchery. Fish health sampling indicated that, overall, bacterial kidney disease levels could be considered relatively low and did not appear to increase after transport to the acclimation facilities. Compared to prior years, Quantitative Health Assessment Indices were relatively low at Pittsburg Landing and Lyons Ferry Hatchery and relatively high at Big Canyon and Captain John Rapids. Mean fork lengths (95% confidence interval) of the release groups ranged from 147.4 mm (146.7-148.1 mm) at Captain John Rapids to 163.7 mm (163.3-164.1 mm) at Pittsburg Landing. Mean condition factors ranged from 1.04 at Pittsburg Landing to 1.23 at Captain John Rapids. Estimated survival (95% confidence interval) of PIT tagged yearlings from release to Lower Granite Dam ranged from 87.8% (82.1-93.4%) for Big Canyon Surplus to 94.1% (90.1-98.1%) for Captain John Rapids. Estimated survival from release to McNary Dam ranged from 58.7% (49.3-68.1%) for Big Canyon Surplus to 71.3% (60.1-82.5%) for Captain John Rapids. Median migration rates to Lower Granite Dam, based on all observations of PIT tagged yearlings from the FCAP facilities, ranged from 9.3 river kilometers per day (rkm/d) for Captain John Rapids to 18.7 rkm/d for Pittsburg Landing. Median migration rates to McNary Dam ranged from 9.0 rkm/d for Lyons Ferry Hatchery to 17.3 rkm/d for Pittsburg Landing. Median travel times from the FCAP facilities were about 7-10 days to Lower Granite Dam and 21-23 days to McNary Dam. Median arrival dates at Lower Granite Dam, based on all observations of PIT tagged yearling groups from the FCAP facilities, were all from April 23-25. The median arrival date for Big Canyon Surplus was May 4. Median arrival dates at McNary Dam for Pittsburg Landing, Big Canyon and Captain John Rapids groups were all from May 7-8. Median arrival dates at McNary Dam were May 17 for Big Canyon Surplus and April 26 for Lyons Ferry Hatchery.« less

  3. Remedial Investigation Report on Chestnut Ridge Operable Unit 2 (Filled Coal Ash Pond/Upper McCoy Branch) at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee. Volume 1. Main Text

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-08-01

    This document is a report on the remedial investigation (RI) of Chestnut Ridge Operable Unit (OU) 2 at the Oak Ridge Y-12 Plant. Chestnut Ridge OU 2 consists of Upper McCoy Branch (UMB), the Filled Coal Ash Pond (FCAP), and the area surrounding the Sluice Channel formerly associated with coal ash disposal in the FCAP. Chestnut Ridge OU 2 is located within the U.S. Department of Energy`s (DOE`s) Oak Ridge Reservation in Anderson County, Tennessee, approximately 24 miles west of Knoxville. The pond is an 8.5-acre area on the southern slope of Chestnut Ridge, 0.5 mile south of the mainmore » Y-12 Plant and geographically separated from the Y-12 Plant by Chestnut Ridge. The elevation of the FCAP is {approximately} 950 ft above mean sea level (msl), and it is relatively flat and largely vegetated. Two small ponds are usually present at the northeast and northwest comers of the FCAP. The Sluice Channel Area extends {approximately}1000 ft from the northern margin of the FCAP to the crest of Chestnut Ridge, which has an elevation of {approximately}1100 ft above msl. The Sluice Channel Area is largely vegetated also. McCoy Branch runs from the top of Chestnut Ridge across the FCAP into Rogers Quarry and out of the quarry where it runs a short distance into Milton Hill Lake at McCoy Embayment, termed UMB. The portion south of Rogers Quarry, within Chestnut Ridge OU 4, is termed Lower McCoy Branch. The DOE Oak Ridge Y-12 Plant disposed of coal ash from its steam plant operations as a slurry that was discharged into an ash retention impoundment; this impoundment is the FCAP. The FCAP was built in 1955 to serve as a settling basin after coal ash slurried over Chestnut Ridge from the Y-12 Plant. The FCAP was constructed by building an earthen dam across the northern tributary of McCoy Branch. The dam was designed to hold 20 years of Y-12 steam plant ash. By July 1967, ash had filled up the impoundment storage behind the dam to within 4 ft of the top.« less

  4. Monitoring and Evaluation of Yearling Fall Chinook Salmon (Oncorhynchus tshawytscha) Released from Acclimation Facilities Upstream of Lower Granite Dam; 2000 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rocklage, Stephen J.; Kellar, Dale S.

    2005-07-01

    The Nez Perce Tribe, in cooperation with the U.S. Fish and Wildlife Service and Washington Department of Fish and Wildlife, conducted monitoring and evaluation studies on Lyons Ferry Hatchery reared yearling fall Chinook salmon Oncorhynchus tshawytscha that were acclimated and released at three Fall Chinook Acclimation Project sites upstream of Lower Granite Dam along with yearlings released on-station from Lyons Ferry Hatchery in 2000. This was the fifth year of a long-term project to supplement natural spawning populations of Snake River stock fall Chinook salmon upstream of Lower Granite Dam. The 397,339 yearlings released from the Fall Chinook Acclimation Projectmore » facilities were short of the 450,000 fish quota. We use Passive Integrated Transponder (PIT) tag technology to monitor the primary performance measures of survival to mainstem dams and migration timing. We also monitor size, condition and tag/mark retention at release. We released 7,477 PIT tagged yearlings from Pittsburg Landing, 7,421 from Big Canyon and 2,488 from Captain John Rapids. The Washington Department of Fish and Wildlife released 980 PIT tagged yearlings from Lyons Ferry Hatchery. Fish health sampling indicated that, overall, bacterial kidney disease levels could be considered relatively low. Compared to prior years, Quantitative Health Assessment Indices were relatively low at Big Canyon and Captain John Rapids and about average at Pittsburg Landing and Lyons Ferry Hatchery. Mean fork lengths (95% confidence interval) of the PIT tagged groups ranged from 157.7 mm (157.3-158.1 mm) at Big Canyon to 172.9 mm (172.2-173.6 mm) at Captain John Rapids. Mean condition factors ranged from 1.06 at Captain John Rapids and Lyons Ferry Hatchery to 1.12 at Big Canyon. Estimated survival (95% confidence interval) of PIT tagged yearlings from release to Lower Granite Dam ranged from 87.0% (84.7-89.4%) for Pittsburg Landing to 95.2% (91.5-98.9%) for Captain John Rapids. Estimated survival from release to McNary Dam ranged from 65.8% (58.5-73.1%) for Lyons Ferry Hatchery to 84.0% (76.2-91.8%) for Captain John Rapids. Median migration rates to Lower Granite Dam, based on all observations of PIT tagged yearlings from the FCAP facilities, ranged from 10.1 river kilometers per day (rkm/d) for Captain John Rapids to 19.1 rkm/d for Pittsburg Landing. Median migration rates to McNary Dam ranged from 6.0 rkm/d for Lyons Ferry Hatchery to 17.3 rkm/d for Pittsburg Landing. Median travel times from the FCAP facilities were about 9-10 days to Lower Granite Dam and 22-25 days to McNary Dam. Median arrival dates at Lower Granite Dam, based on all observations of PIT tagged yearling groups from Pittsburg Landing, Big Canyon and Captain John Rapids, were all from April 21-22. Median arrival dates at McNary Dam for Pittsburg Landing, Big Canyon and Captain John Rapids groups were all from May 5-6. The median arrival date at McNary Dam was April 24 for Lyons Ferry Hatchery yearlings.« less

  5. Monitoring and Evaluation of Yearling Fall Chinook Salmon (Oncorhynchus tshawytscha) Released from Acclimation Facilities Upstream of Lower Granite Dam; 2001 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rocklage, Stephen J.; Kellar, Dale S.

    2005-07-01

    The Nez Perce Tribe, in cooperation with the U.S. Fish and Wildlife Service and Washington Department of Fish and Wildlife, conducted monitoring and evaluation studies on Lyons Ferry Hatchery reared yearling fall Chinook salmon Oncorhynchus tshawytscha that were acclimated and released at three Fall Chinook Acclimation Project sites upstream of Lower Granite Dam along with yearlings released on-station from Lyons Ferry Hatchery in 2001. This was the sixth year of a long-term project to supplement natural spawning populations of Snake River stock fall Chinook salmon upstream of Lower Granite Dam. The 318,932 yearlings released from the Fall Chinook Acclimation Projectmore » facilities were short of the 450,000 fish quota. We use Passive Integrated Transponder (PIT) tag technology to monitor the primary performance measures of survival to mainstem dams and migration timing. We also monitor size, condition and tag/mark retention at release. We released 7,503 PIT tagged yearlings from Pittsburg Landing, 7,499 from Big Canyon and 2,518 from Captain John Rapids. The Washington Department of Fish and Wildlife released 991 PIT tagged yearlings from Lyons Ferry Hatchery. Fish health sampling indicated that, overall, bacterial kidney disease levels could be considered relatively low. Compared to prior years, Quantitative Health Assessment Indices were relatively low at Big Canyon and Captain John Rapids and about average at Pittsburg Landing and Lyons Ferry Hatchery. Mean fork lengths (95% confidence interval) of the PIT tagged groups ranged from 155.4 mm (154.7-156.1 mm) at Captain John Rapids to 171.6 mm (170.7-172.5 mm) at Lyons Ferry Hatchery. Mean condition factors ranged from 1.02 at Lyons Ferry Hatchery to 1.16 at Big Canyon and Captain John Rapids. Estimated survival (95% confidence interval) of PIT tagged yearlings from release to Lower Granite Dam ranged from 74.4% (73.2-75.5%) for Big Canyon to 85.2% (83.5-87.0%) for Captain John Rapids. Estimated survival from release to McNary Dam ranged from 37.9% (36.0-40.0%) for Pittsburg Landing to 57.9% (53.0-62.8%) for Lyons Ferry Hatchery. Median migration rates to Lower Granite Dam, based on all observations of PIT tagged yearlings from the FCAP facilities, ranged from 6.3 river kilometers per day (rkm/d) for Big Canyon to 10.8 rkm/d for Pittsburg Landing. Median migration rates to McNary Dam ranged from 5.2 rkm/d for Lyons Ferry Hatchery to 10.9 rkm/d for Pittsburg Landing. Median travel times from the FCAP facilities were about 13-17 days to Lower Granite Dam and 31-37 days to McNary Dam. Median arrival dates at Lower Granite Dam, based on all observations of PIT tagged yearling groups from Pittsburg Landing, Big Canyon and Captain John Rapids, were all from April 26-27. Median arrival dates at McNary Dam for Pittsburg Landing, Big Canyon and Captain John Rapids groups were all from May 14-18. The median arrival date at McNary Dam was May 13 for Lyons Ferry Hatchery yearlings.« less

  6. Familial pancreatic cancer: the case for prophylactic pancreatectomy in lieu of serial screening and shared decision making.

    PubMed

    Iskandar, Mazen E; Wayne, Michael G; Steele, Justin G; Cooperman, Avram M

    2014-01-01

    At-risk family members with familial pancreatic cancer (FCaP) face uncertainty regarding the individual risk of developing pancreatic cancer (CaP) and whether to choose serial screening or prophylactic pancreatectomy to avoid CaP. We treated 2 at-risk siblings with a history of FCaP, congenital hepatic fibrosis (CHF), and jaundice secondary to a bile duct stricture. In one, a pancreaticoduodenal resection was done and in the second a total pancreatectomy. Malignancy was not present, but extensive pancreatic intraepithelial neoplasia (PanIn) 2 was present throughout both pancreata. The clinical course and literature review are presented along with the previously unreported association of CHF and CaP.

  7. Two neuropeptides colocalized in a command-like neuron use distinct mechanisms to enhance its fast synaptic connection.

    PubMed

    Koh, H Y; Vilim, F S; Jing, J; Weiss, K R

    2003-09-01

    In many neurons more than one peptide is colocalized with a classical neurotransmitter. The functional consequence of such an arrangement has been rarely investigated. Here, within the feeding circuit of Aplysia, we investigate at a single synapse the actions of two modulatory neuropeptides that are present in a cholinergic interneuron. In combination with previous work, our study shows that the command-like neuron for feeding, CBI-2, contains two neuropeptides, feeding circuit activating peptide (FCAP) and cerebral peptide 2 (CP2). Previous studies showed that high-frequency prestimulation or repeated stimulation of CBI-2 increases the size of CBI-2 to B61/62 excitatory postsynaptic potentials (EPSPs) and shortens the latency of firing of neuron B61/62 in response to CBI-2 stimulation. We find that both FCAP and CP2 mimic these two effects. The variance method of quantal analysis indicates that FCAP increases the calculated quantal size (q) and CP2 increases the calculated quantal content (m) of EPSPs. Since the PSP amplitude represents the product of q and m, the joint action of the two peptides is expected to be cooperative. This observation suggests a possible functional implication for multiple neuropeptides colocalized with a classical neurotransmitter in one neuron.

  8. Familial Pancreatic Cancer: The Case for Prophylactic Pancreatectomy in Lieu of Serial Screening and Shared Decision Making

    PubMed Central

    Iskandar, Mazen E.; Wayne, Michael G.; Steele, Justin G.; Cooperman, Avram M.

    2014-01-01

    At-risk family members with familial pancreatic cancer (FCaP) face uncertainty regarding the individual risk of developing pancreatic cancer (CaP) and whether to choose serial screening or prophylactic pancreatectomy to avoid CaP. We treated 2 at-risk siblings with a history of FCaP, congenital hepatic fibrosis (CHF), and jaundice secondary to a bile duct stricture. In one, a pancreaticoduodenal resection was done and in the second a total pancreatectomy. Malignancy was not present, but extensive pancreatic intraepithelial neoplasia (PanIn) 2 was present throughout both pancreata. The clinical course and literature review are presented along with the previously unreported association of CHF and CaP. PMID:25506012

  9. Peptidergic contribution to posttetanic potentiation at a central synapse of aplysia.

    PubMed

    Koh, Hae-Young; Weiss, Klaudiusz R

    2005-08-01

    Posttetanic potentiation (PTP)-like phenomena appear to be mediated by a variety of mechanisms. Although neuropeptides are located in a large number of neurons and many neuropeptides, like PTP, can enhance synaptic transmission, there is a paucity of studies indicating that peptides may actually participate in PTP. Here, we utilize a single central synapse in the feeding circuit of Aplysia to investigate a possible peptidergic contribution to PTP in the CNS. The cholinergic command-like interneuron, cerebral-buccal interneuron 2 (CBI-2), contains two neuropeptides, feeding circuit activating peptide (FCAP) and cerebral peptide 2 (CP2). Previous studies showed that tetanic prestimulation or repeated stimulation of CBI-2, as well as perfusion of FCAP and CP2, increase the size of the cholinergic excitatory postsynaptic potentials (EPSPs) that CBI-2 evokes in the motoneurons B61/62 and shorten the latency to initiate B61/62 firing in response to CBI-2 stimulation. We used temperature-dependent suppression of peptide release and occlusion experiments to examine the possible contribution of FCAP and CP2 to PTP at the CBI-2 to B61/62 synapse. When peptide release was suppressed, perfusion of exogenous peptides increased the size of posttetanic EPSPs. In contrast, when peptide release was not suppressed, exogenous peptides did not enhance the size of posttetanic EPSPs, thus indicating occlusion. Temperature manipulation and occlusion experiments also indicated that peptides extend PTP duration. This peptide-dependent prolongation of PTP has functional consequences in that it extends the duration of time during which the latency to initiate B61/62 firing in response to CBI-2 stimulation is shortened.

  10. 77 FR 65098 - Board Policy Statements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-25

    ... Disability in Agency Programs and Activities FCA-PS-68 FCS Building Association Management Operations... staff for deciding and taking action in these critical areas. Importance Unquestionably, the employees... programs, activities, and services will be treated fairly. The Chairman and Chief Executive Officer (CEO...

  11. Yang-Lee zeros, Julia sets, and their singularity spectra

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, B.; Lin, B.

    1989-05-01

    We have studied the global scaling properties of the Julia sets of the Yang-Lee zeros of the s-state Potts model on the diamond hierarchical lattice. The singularity spectrum f(..cap alpha..) and the generalized dimension D/sub q/ are calculated for different s values. General observations are made on their variations.

  12. 76 FR 71343 - Ethics, Independence, Arm's-Length Role, Ex Parte Communications and Open Government

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-17

    ... FARM CREDIT ADMINISTRATION [FCA-PS-81; NV 11-25] Ethics, Independence, Arm's-Length Role, Ex Parte...) and the public. The FCA Board also is committed to the ethics principles and laws governing all Executive Branch employees and to the Agency's strong ethics program. DATES: Effective Date: November 7...

  13. Army Manpower Cost System (AMCOS): Active Enlisted Force Prototype

    DTIC Science & Technology

    1986-03-01

    cost element in both economic and budget models includes both a soldier’s Base Pay and the Service’s FICA contribu- tion at the current tax rate . a...mean base pay for the position calculated from BP T I FCAP - curret maxilum ICA payable FRATE - current FICA tax rate Tlij - total base pay distributed...Group, Santa Monica, 1982. Butler, R. and T. Neches, " HARDMAN Program Manager’s LCC Handbook: Avionics Equip- ments," D-201, The Assessment Group

  14. Complementary interactions between command-like interneurons that function to activate and specify motor programs.

    PubMed

    Wu, Jin-Sheng; Wang, Nan; Siniscalchi, Michael J; Perkins, Matthew H; Zheng, Yu-Tong; Yu, Wei; Chen, Song-an; Jia, Ruo-nan; Gu, Jia-Wei; Qian, Yi-Qing; Ye, Yang; Vilim, Ferdinand S; Cropper, Elizabeth C; Weiss, Klaudiusz R; Jing, Jian

    2014-05-07

    Motor activity is often initiated by a population of command-like interneurons. Command-like interneurons that reliably drive programs have received the most attention, so little is known about how less reliable command-like interneurons may contribute to program generation. We study two electrically coupled interneurons, cerebral-buccal interneuron-2 (CBI-2) and CBI-11, which activate feeding motor programs in the mollusk Aplysia californica. Earlier work indicated that, in rested preparations, CBI-2, a powerful activator of programs, can trigger ingestive and egestive programs. CBI-2 reliably generated ingestive patterns only when it was repeatedly stimulated. The ability of CBI-2 to trigger motor activity has been attributed to the two program-promoting peptides it contains, FCAP and CP2. Here, we show that CBI-11 differs from CBI-2 in that it contains FCAP but not CP2. Furthermore, it is weak in its ability to drive programs. On its own, CBI-11 is therefore less effective as a program activator. When it is successful, however, CBI-11 is an effective specifier of motor activity; that is, it drives mostly ingestive programs. Importantly, we found that CBI-2 and CBI-11 complement each other's actions. First, prestimulation of CBI-2 enhanced the ability of CBI-11 to drive programs. This effect appears to be partly mediated by CP2. Second, coactivation of CBI-11 with CBI-2 makes CBI-2 programs immediately ingestive. This effect may be mediated by specific actions that CBI-11 exerts on pattern-generating interneurons. Therefore, different classes of command-like neurons in a motor network may make distinct, but potentially complementary, contributions as either activators or specifiers of motor activity.

  15. Complementary Interactions between Command-Like Interneurons that Function to Activate and Specify Motor Programs

    PubMed Central

    Wu, Jin-Sheng; Wang, Nan; Siniscalchi, Michael J.; Perkins, Matthew H.; Zheng, Yu-Tong; Yu, Wei; Chen, Song-an; Jia, Ruo-nan; Gu, Jia-Wei; Qian, Yi-Qing; Ye, Yang; Vilim, Ferdinand S.; Cropper, Elizabeth C.; Weiss, Klaudiusz R.

    2014-01-01

    Motor activity is often initiated by a population of command-like interneurons. Command-like interneurons that reliably drive programs have received the most attention, so little is known about how less reliable command-like interneurons may contribute to program generation. We study two electrically coupled interneurons, cerebral-buccal interneuron-2 (CBI-2) and CBI-11, which activate feeding motor programs in the mollusk Aplysia californica. Earlier work indicated that, in rested preparations, CBI-2, a powerful activator of programs, can trigger ingestive and egestive programs. CBI-2 reliably generated ingestive patterns only when it was repeatedly stimulated. The ability of CBI-2 to trigger motor activity has been attributed to the two program-promoting peptides it contains, FCAP and CP2. Here, we show that CBI-11 differs from CBI-2 in that it contains FCAP but not CP2. Furthermore, it is weak in its ability to drive programs. On its own, CBI-11 is therefore less effective as a program activator. When it is successful, however, CBI-11 is an effective specifier of motor activity; that is, it drives mostly ingestive programs. Importantly, we found that CBI-2 and CBI-11 complement each other's actions. First, prestimulation of CBI-2 enhanced the ability of CBI-11 to drive programs. This effect appears to be partly mediated by CP2. Second, coactivation of CBI-11 with CBI-2 makes CBI-2 programs immediately ingestive. This effect may be mediated by specific actions that CBI-11 exerts on pattern-generating interneurons. Therefore, different classes of command-like neurons in a motor network may make distinct, but potentially complementary, contributions as either activators or specifiers of motor activity. PMID:24806677

  16. 33 CFR 334.1390 - Pacific Ocean off the Pacific Missile Range Facility at Barking Sands, Island of Kauai, Hawaii...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Missile Range Facility at Barking Sands, Island of Kauai, Hawaii; danger zone. 334.1390 Section 334.1390... AND RESTRICTED AREA REGULATIONS § 334.1390 Pacific Ocean off the Pacific Missile Range Facility at... Pacific Missile Range Facility range boats, beach markings including beach signs along the north and south...

  17. 33 CFR 334.1390 - Pacific Ocean at Barking Sands, Island of Kauai, Hawaii; missile range facility.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., Island of Kauai, Hawaii; missile range facility. 334.1390 Section 334.1390 Navigation and Navigable... REGULATIONS § 334.1390 Pacific Ocean at Barking Sands, Island of Kauai, Hawaii; missile range facility. (a... individual basis, by prior arrangement with the Commanding Officer, Pacific Missile Range Facility, Hawaiian...

  18. 33 CFR 334.1390 - Pacific Ocean at Barking Sands, Island of Kauai, Hawaii; missile range facility.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., Island of Kauai, Hawaii; missile range facility. 334.1390 Section 334.1390 Navigation and Navigable... REGULATIONS § 334.1390 Pacific Ocean at Barking Sands, Island of Kauai, Hawaii; missile range facility. (a... individual basis, by prior arrangement with the Commanding Officer, Pacific Missile Range Facility, Hawaiian...

  19. 33 CFR 334.1390 - Pacific Ocean at Barking Sands, Island of Kauai, Hawaii; missile range facility.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., Island of Kauai, Hawaii; missile range facility. 334.1390 Section 334.1390 Navigation and Navigable... REGULATIONS § 334.1390 Pacific Ocean at Barking Sands, Island of Kauai, Hawaii; missile range facility. (a... individual basis, by prior arrangement with the Commanding Officer, Pacific Missile Range Facility, Hawaiian...

  20. 33 CFR 334.1390 - Pacific Ocean at Barking Sands, Island of Kauai, Hawaii; missile range facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., Island of Kauai, Hawaii; missile range facility. 334.1390 Section 334.1390 Navigation and Navigable... REGULATIONS § 334.1390 Pacific Ocean at Barking Sands, Island of Kauai, Hawaii; missile range facility. (a... individual basis, by prior arrangement with the Commanding Officer, Pacific Missile Range Facility, Hawaiian...

  1. 78 FR 27124 - Pacific Ocean Off the Kekaha Range Facility at Barking Sands, Island of Kauai, Hawaii; Danger Zone

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-09

    ... the Kekaha Range Facility at Barking Sands, Island of Kauai, Hawaii; Danger Zone AGENCY: U.S. Army... Pacific Ocean off the Kekaha Range Facility, Barking Sands, Island of Kauai, Hawaii. The proposed... Kekaha Range Facility at Barking Sands, Island of Kauai, Hawaii. The Corps authority to establish this...

  2. Aberrant Production of Th1/Th2/Th17-Related Cytokines in Serum of C57BL/6 Mice after Short-Term Formaldehyde Exposure

    PubMed Central

    Wei, Haiyan; Tan, Kehong; Sun, Rongli; Yin, Lihong; Zhang, Juan; Pu, Yuepu

    2014-01-01

    Previous studies have shown that formaldehyde (FA) could cause immunotoxicity by changing the number of T lymphocytes and that cytokines play a pivotal role in the regulation of T lymphocytes. However, the previously used cytokine detection methods are difficult to use in the measurement of several cytokines in a small amount of sample for one test. Therefore, the cytometric bead array (CBA) technique was used. CBA showed better analytical efficiency and sensitivity than the previous methods. C57BL/6 mice were exposed to the control (normal saline), low FA concentration (0.5 mg/kg), and high FA concentration (2 mg/kg) for 1 week or 1 month. The contents of cytokines, including Th1-related cytokines (IL-2, IFN-γ, and tumor necrosis factor), Th2-related cytokines (IL-4, IL-6, and IL-10), and Th17-related cytokines (IL-17A), were measured by using the BD FACS Canto II Flow Cytometer and analyzed by FCAP ArrayTM Software. Th1/Th2/Th17-related cytokines showed a slightly decreasing trend after low FA exposure. Conversely, a significantly increasing trend was found after high FA exposure. Th1/Th2/Th17-related cytokines all serve important functions in the immune reactions in mice after FA exposure. PMID:25264680

  3. Ecological effects of contaminants in McCoy Branch, 1991--1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ryon, M.G.

    1996-09-01

    The 1984 Hazardous and Solid Waste Amendments to the Resource Conservation and Recovery Act (RCRA) required assessment of all current and former solid waste management units. Following guidelines under RCRA and the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), a remedial investigation (RI) was required of the Y-12 Plant for their filled coal ash pond (FCAP) and associated areas on McCoy Branch. The RI process was initiated and assessments were presented. Because the disposal of coal ash in the ash pond, McCoy Branch, and Rogers Quarry was not consistent with the Tennessee Water Quality Act, several remediation steps weremore » implemented between 1986 and 1994 for McCoy Branch to address disposal problems. The required ecological risk assessments of McCoy Branch watershed included provisions for biological monitoring of the watershed. The objectives of the biological monitoring were to (1) document changes in biological quality of McCoy Branch after completion of a pipeline bypassing upper McCoy Branch and further, after termination of all discharges to Rogers Quarry, (2) provide guidance on the need for additional remediation, and (3) evaluate the effectiveness of implemented remedial actions. The data from the biological monitoring program may also determine whether the goals of protection of human health and the environment of McCoy Branch are being accomplished.« less

  4. Inspired Planning

    ERIC Educational Resources Information Center

    Erickson, Paul W.

    2009-01-01

    Long-range facility planning is a comprehensive process for preparing education institutions for the future and confirm that facilities meet current needs. A long-range facilities plan (LRFP) evaluates how facilities support programs and the educational needs of students, staff and the community. Each school district or college has unique needs…

  5. 33 CFR 165.1406 - Safety Zone: Pacific Missile Range Facility (PMRF), Barking Sands, Island of Kauai, Hawaii.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Safety Zone: Pacific Missile Range Facility (PMRF), Barking Sands, Island of Kauai, Hawaii. 165.1406 Section 165.1406 Navigation and... Areas Fourteenth Coast Guard District § 165.1406 Safety Zone: Pacific Missile Range Facility (PMRF...

  6. 33 CFR 165.1406 - Safety Zone: Pacific Missile Range Facility (PMRF), Barking Sands, Island of Kauai, Hawaii.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Safety Zone: Pacific Missile Range Facility (PMRF), Barking Sands, Island of Kauai, Hawaii. 165.1406 Section 165.1406 Navigation and... Areas Fourteenth Coast Guard District § 165.1406 Safety Zone: Pacific Missile Range Facility (PMRF...

  7. 33 CFR 165.1406 - Safety Zone: Pacific Missile Range Facility (PMRF), Barking Sands, Island of Kauai, Hawaii.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Safety Zone: Pacific Missile Range Facility (PMRF), Barking Sands, Island of Kauai, Hawaii. 165.1406 Section 165.1406 Navigation and... Areas Fourteenth Coast Guard District § 165.1406 Safety Zone: Pacific Missile Range Facility (PMRF...

  8. 33 CFR 165.1406 - Safety Zone: Pacific Missile Range Facility (PMRF), Barking Sands, Island of Kauai, Hawaii.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Safety Zone: Pacific Missile Range Facility (PMRF), Barking Sands, Island of Kauai, Hawaii. 165.1406 Section 165.1406 Navigation and... Areas Fourteenth Coast Guard District § 165.1406 Safety Zone: Pacific Missile Range Facility (PMRF...

  9. 33 CFR 165.1406 - Safety Zone: Pacific Missile Range Facility (PMRF), Barking Sands, Island of Kauai, Hawaii.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Safety Zone: Pacific Missile Range Facility (PMRF), Barking Sands, Island of Kauai, Hawaii. 165.1406 Section 165.1406 Navigation and... Areas Fourteenth Coast Guard District § 165.1406 Safety Zone: Pacific Missile Range Facility (PMRF...

  10. Concept definition study for an extremely large aerophysics range facility

    NASA Technical Reports Server (NTRS)

    Swift, H.; Witcofski, R.

    1992-01-01

    The development of a large aerophysical ballistic range facility is considered to study large-scale hypersonic flows at high Reynolds numbers for complex shapes. A two-stage light gas gun is considered for the hypervelocity launcher, and the extensive range tankage is discussed with respect to blast suppression, model disposition, and the sabot impact tank. A layout is given for the large aerophysics facility, and illustrations are provided for key elements such as the guide rail. The paper shows that such a facility could be used to launch models with diameters approaching 250 mm at velocities of 6.5 km/s with peak achievable accelerations of not more than 85.0 kgs. The envisioned range would provide gas-flow facilities capable of controlling the modeled quiescent atmospheric conditions. The facility is argued to be a feasible and important step in the investigation and experiment of such hypersonic vehicles as the National Aerospace Plane.

  11. Identification of potential recovery facilities for designing a reverse supply chain network using physical programming

    NASA Astrophysics Data System (ADS)

    Pochampally, Kishore K.; Gupta, Surendra M.; Kamarthi, Sagar V.

    2004-02-01

    Although there are many quantitative models in the literature to design a reverse supply chain, every model assumes that all the recovery facilities that are engaged in the supply chain have enough potential to efficiently re-process the incoming used products. Motivated by the risk of re-processing used products in facilities of insufficient potentiality, this paper proposes a method to identify potential facilities in a set of candidate recovery facilities operating in a region where a reverse supply chain is to be established. In this paper, the problem is solved using a newly developed method called physical programming. The most significant advantage of using physical programming is that it allows a decision maker to express his preferences for values of criteria (for comparing the alternatives), not in the traditional form of weights but in terms of ranges of different degrees of desirability, such as ideal range, desirable range, highly desirable range, undesirable range, and unacceptable range. A numerical example is considered to illustrate the proposed method.

  12. 78 FR 39198 - Pacific Ocean Off the Pacific Missile Range Facility at Barking Sands, Island of Kauai, Hawaii...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-01

    ... the Pacific Missile Range Facility at Barking Sands, Island of Kauai, Hawaii; Danger Zone AGENCY: U.S... off the Pacific Missile Range Facility at Barking Sands, Island of Kauai, Hawaii. The U.S. Navy... at Barking Sands, Island of Kauai, Hawaii by increasing the water area historically noted on nautical...

  13. Missed opportunities and barriers for vaccination: a descriptive analysis of private and public health facilities in four African countries.

    PubMed

    Olorunsaiye, Comfort Zuyeali; Langhamer, Margaret Shaw; Wallace, Aaron Stuart; Watkins, Margaret Lyons

    2017-01-01

    Missed opportunities and barriers to vaccination limit progress toward achieving high immunization coverage and other global immunization goals. Little is known about vaccination practices contributing to missed opportunities and barriers among private healthcare providers in Africa. Service Provision Assessments (SPA) of representative samples of health facilities in four African countries (Kenya, Tanzania, Senegal, Malawi) in 2010-2015 were used to describe missed opportunities and barriers for vaccination in public, private for-profit, private not-for-profit and faith-based facilities. Data included vaccination practices, observations during sick child and antenatal visits, and exit interviews following sick child visits. Data from 3,219 health facilities, 11,613 sick child visits and 8,698 antenatal visits were included. A smaller proportion of for-profit facilities offered child vaccination services (country range, 25-37%) than did public facilities (range, 90-96%). The proportion of facilities offering pentavalent vaccine (diphtheria, pertussis, tetanus, hepatitis B and Haemophilus influenza type b antigens) daily ranged 0-77% across countries and facility types. Less than 33% of for-profit facilities in any country offered measles vaccination daily. A minority of public or private providers assessed the child's vaccination status during a sick child visit (range by country and facility type, 14-44%), or offered tetanus toxoid during antenatal visits (range, 19-51%). Very few providers discussed the importance of newborn vaccination. Substantial missed opportunities for, and barriers to, vaccination were identified across this representative sample of health facilities in four African countries. Strategies are needed to ensure that private and public providers implement practices to minimize barriers and missed opportunities for vaccination.

  14. Missed opportunities and barriers for vaccination: a descriptive analysis of private and public health facilities in four African countries

    PubMed Central

    Olorunsaiye, Comfort Zuyeali; Langhamer, Margaret Shaw; Wallace, Aaron Stuart; Watkins, Margaret Lyons

    2017-01-01

    Introduction Missed opportunities and barriers to vaccination limit progress toward achieving high immunization coverage and other global immunization goals. Little is known about vaccination practices contributing to missed opportunities and barriers among private healthcare providers in Africa. Methods Service Provision Assessments (SPA) of representative samples of health facilities in four African countries (Kenya, Tanzania, Senegal, Malawi) in 2010-2015 were used to describe missed opportunities and barriers for vaccination in public, private for-profit, private not-for-profit and faith-based facilities. Data included vaccination practices, observations during sick child and antenatal visits, and exit interviews following sick child visits. Results Data from 3,219 health facilities, 11,613 sick child visits and 8,698 antenatal visits were included. A smaller proportion of for-profit facilities offered child vaccination services (country range, 25-37%) than did public facilities (range, 90-96%). The proportion of facilities offering pentavalent vaccine (diphtheria, pertussis, tetanus, hepatitis B and Haemophilus influenza type b antigens) daily ranged 0-77% across countries and facility types. Less than 33% of for-profit facilities in any country offered measles vaccination daily. A minority of public or private providers assessed the child’s vaccination status during a sick child visit (range by country and facility type, 14-44%), or offered tetanus toxoid during antenatal visits (range, 19-51%). Very few providers discussed the importance of newborn vaccination. Conclusion Substantial missed opportunities for, and barriers to, vaccination were identified across this representative sample of health facilities in four African countries. Strategies are needed to ensure that private and public providers implement practices to minimize barriers and missed opportunities for vaccination. PMID:29296141

  15. A unique high heat flux facility for testing hypersonic engine components

    NASA Technical Reports Server (NTRS)

    Melis, Matthew E.; Gladden, Herbert J.

    1990-01-01

    This paper describes the Hot Gas Facility, a unique, reliable, and cost-effective high-heat-flux facility for testing hypersonic engine components developed at the NASA Lewis Research Center. The Hot Gas Facility is capable of providing heat fluxes ranging from 200 Btu/sq ft per sec on flat surfaces up to 8000 Btu/sq ft per sec at a leading edge stagnation point. The usefulness of the Hot Gas Facility for the NASP community was demonstrated by testing hydrogen-cooled structures over a range of temperatures and pressures. Ranges of the Reynolds numbers, Prandtl numbers, enthalpy, and heat fluxes similar to those expected during hypersonic flights were achieved.

  16. 78 FR 25973 - Final Environmental Impact Statement for the Real Property Master Plan at the Presidio of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-03

    ... implementing both short-range and long-range projects. Proposed facility improvements and phased construction... Institute Foreign Language Center (DLIFLC). Facilities, construction, improvements, renovations... have modern facilities consistent with Army standards well into the 21st Century. The overall goal is...

  17. Exposure to bioaerosols in the selected agricultural facilities of the Ukraine and Poland - a review.

    PubMed

    Tsapko, Valentin G; Chudnovets, Alla J; Sterenbogen, Marina J; Papach, Vladimir V; Dutkiewicz, Jacek; Skórska, Czesława; Krysińska-Traczyk, Ewa; Golec, Marcin

    2011-01-01

    The aim of this work was to review the studies on bioaerosols which were carried out in the years 1972-2009 in following branches of agricultural industry in the Ukraine and Poland: animal farms for cows and pigs, animal feed facilities, production of biofuel from rape, herb farms and herb processing facilities. In all facilities were determined: concentration of dust and microorganisms in the air and species composition of microflora. Moreover, in Polish animal farms, herb farms and herb processing facilities, as well as in the Ukrainian animal feed facilities, was determined the concentration of bacterial endotoxin in the air. Dust concentrations in animal farms located in the Ukraine and Poland ranged from 6-200 mg/m(3) and from 0.25-14.05 mg/m(3), respectively, while in animal feed facilities they ranged from 35-306 mg/m(3) and from 3.8-405 mg/m(3), respectively. Dust concentrations in the facilities producing biofuel from rape in the Ukraine were in the range 3.6-28 mg/m(3), whereas on herb farms and in herb processing facilities in Poland they were in the range 0.8- 1,319.6 mg/m(3), and 2.2-946 mg/m(3), respectively. The determined values exceeded in most cases the maximal acceptable concentration (MAC) which in the Ukraine and Poland is equal to 4 mg/m(3). The concentrations of microorganisms on animal farms located in the Ukraine and Poland ranged from 5.5 x 10(4)- 1.9 x 10(7) cfu/m(3) and from 4.7 x 10(4)-1.5 x 10(6) cfu/m(3), respectively, while in animal feed facilities they ranged from 2.7 x 10(4)-2.6 x 10(9) cfu/m(3) and from 1.7 x 10(3)-2.0 x 10(6) cfu/m(3), respectively. Concentrations of microorganisms in the facilities producing biofuel from rape in the Ukraine were in the range 1.5 x 10(3)-5.7 x 10(6) cfu/m(3), whereas on herb farms and in herb processing facilities in Poland they were in the ranges of 8.8 x 10(2)-8.0 x 10(6) cfu/m(3), and 9.7 x 10(3)-6.3 x 10(5) cfu/m(3), respectively. The determined values exceeded in most cases the maximal acceptable concentration (MAC) which in the Ukraine is equal to 5.0 x 10(4) cfu/m(3). The concentrations of endotoxin in Polish animal houses were in the range 0.00125-75.0 ug/m(3), whereas on herb farms and herb processing facilities they were in the ranges of 0.0045- 2,448.8 ug/m(3) and 0.2-681.0 ug/m(3), respectively, and in the Ukrainian animal feed facilities were within the range 0.008-240.0 ug/m(3). They exceeded in most cases the level of 0.2 ug/m(3) proposed as a threshold. In the air microflora of examined facilities prevailed Gram-positive bacteria (corynebacteria, cocci, spore-forming bacilli, actinomycetes) of which some (Arthrobacter spp., thermophilic actinomycetes) could be a cause of allergic alveolitis (hypersensitivity pneumonitis). Among Gram-negative bacteria isolated from the air of agricultural settings dominated the epiphytic species Pantoea agglomerans, possessing potent allergenic and endotoxic properties. Fungi were abundant in the air of the Ukrainian agricultural settings and comprised species able to produce harmful mycotoxins. In conclusion, the airborne biological factors in stated concentrations may exert harmful effects on the state of the health of exposed workers. Formation of the bioaerosol depends on the specificity of the setting, kind of technological operations, degree of mechanization, properties of processed materials, temperature and humidity, and concentration of dust in the air.

  18. The Abbott School Construction Program: Report on the NJ Department of Education Proposed Regulations on Long-Range Facilities Plans

    ERIC Educational Resources Information Center

    Ponessa, Joan

    2004-01-01

    This report on Long Range Facilities Plans (LRFPs) analyzes regulations proposed by the New Jersey Department of Education (NJDOE) to implement the Educational Facilities Construction and Financing Act. (EFCFA). EFCFA, which authorizes and governs New Jersey's public school construction program, was enacted in July 2000 to implement the State…

  19. Long Range Facilities Planning and Design Implementation for Students with Disabilities: A Guide for New Jersey School Districts

    ERIC Educational Resources Information Center

    Lowenkron, Ruth; Ponessa, Joan

    2005-01-01

    The long range facilities planning (LRFP) process presents a wonderful opportunity for New Jersey's school districts to re-examine and strengthen their long term planning for educational adequacy in 21st century school facilities. It provides an opportunity for districts to work closely with the special education community to ensure that New…

  20. Western Aeronautical Test Range

    NASA Technical Reports Server (NTRS)

    Sakahara, Robert D.

    2008-01-01

    This viewgraph presentation reviews the work of the Western Aeronautical Test Range (WATR). NASA's Western Aeronautical Test Range is a network of facilities used to support aeronautical research, science missions, exploration system concepts, and space operations. The WATR resides at NASA's Dryden Flight Research Center located at Edwards Air Force Base, California. The WATR is a part of NASA's Corporate Management of Aeronautical Facilities and funded by the Strategic Capability Asset Program (SCAP). Maps show the general location of the WATR area that is used for aeronautical testing and evaluation. The products, services and facilities of WATR are discussed,

  1. Advanced Simulation in Undergraduate Pilot Training (ASUPT) Facility Utilization Plan.

    ERIC Educational Resources Information Center

    Hagin, William V.; Smith, James F.

    The capabilities of a flight simulation research facility located at Williams AFB, Arizona are described. Research philosophy to be applied is discussed. Long range and short range objectives are identified. A time phased plan for long range research accomplishment is described. In addition, some examples of near term research efforts which will…

  2. The NASA Lewis Research Center Water Tunnel Facility

    NASA Technical Reports Server (NTRS)

    Wasserbauer, Charles A.

    1997-01-01

    A water tunnel facility specifically designed to investigate internal fluid duct flows has been built at the NASA Research Center. It is built in a modular fashion so that a variety of internal flow test hardware can be installed in the facility with minimal facility reconfiguration. The facility and test hardware interfaces are discussed along with design constraints for future test hardware. The inlet chamber flow conditioning approach is also detailed. Instrumentation and data acquisition capabilities are discussed. The incoming flow quality has been documented for about one quarter of the current facility operating range. At that range, there is some scatter in the data in the turbulent boundary layer which approaches 10 percent of the duct radius leading to a uniform core.

  3. A summary of existing and planned experiment hardware for low-gravity fluids research

    NASA Technical Reports Server (NTRS)

    Hill, Myron E.; Omalley, Terence F.

    1991-01-01

    An overview is presented of (1) existing ground-based, low gravity research facilities, with examples of hardware capabilities, and (2) existing and planned space-based research facilities, with examples of current and past flight hardware. Low-gravity, ground-based facilities, such as drop towers and aircraft, provide the experimenter with quick turnaround time, easy access to equipment, gravity levels ranging from 10(exp -2) to 10(exp -6) G, and low-gravity durations ranging from 2 to 30 sec. Currently, the only operational space-based facility is the Space Shuttle. The Shuttle's payload bay and middeck facilities are described. Existing and planned low-gravity fluids research facilities are also described with examples of experiments and hardware capabilities.

  4. A low-density boundary-layer wind tunnel facility

    NASA Technical Reports Server (NTRS)

    White, B. R.

    1987-01-01

    This abstract describes a low-density wind-tunnel facility that was established at NASA Ames in order to aid interpretation and understanding of data received from the Mariner and Viking spacecraft through earth-based simulation. The wind tunnel is a boundary-layer type which is capable of operating over a range of air densities ranging from 0.01 to 1.24 kg/cu m, with the lower values being equivalent to the near-surface density of the planet Mars. Although the facility was developed for space and extraterrestrial simulation, it also can serve as a relatively large-scale, low-density aerodynamic test facility. A description of this unique test facility and some Pitot-tube and hot-wire anemometry data acquired in the facility are presented.

  5. Uncertainty and Traceability for the CEESI Iowa Natural Gas Facility.

    PubMed

    Johnson, Aaron; Kegel, Tom

    2004-01-01

    This paper analyzes the uncertainty of a secondary flow measurement facility that calibrates a significant fraction of United States and foreign flow meters used for custody transfer of natural gas. The facility, owned by the Colorado Experimental Engineering Station Incorporated (CEESI), is located in Iowa. This facility measures flow with nine turbine meter standards, each of which is traceable to the NIST primary flow standard. The flow capacity of this facility ranges from 0.7 actual m(3)/s to 10.7 actual m(3)/s at nominal pressures of 7174 kPa and at ambient temperatures. Over this flow range the relative expanded flow uncertainty varies from 0.28 % to 0.30 % (depending on flow).

  6. Shoreline Erosion and Proposed Control at Experimental Facility 15-Spesutie Island

    DTIC Science & Technology

    2017-09-01

    Island, it is made up of various facilities and ranges designed for weapons testing as well as automotive testing . These ranges belong to the...ARL-SR-0383 ● SEP 2017 US Army Research Laboratory Shoreline Erosion and Proposed Control at Experimental Facility 15–Spesutie...in this report are not to be construed as an official Department of the Army position unless so designated by other authorized documents. Citation

  7. The Dust Accelerator Facility of the Colorado Center for Lunar Dust and Atmospheric Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Horanyi, M.; Colette, A.; Drake, K.

    2011-11-29

    The NASA Lunar Institute's Colorado Center for Lunar Dust and Atmospheric Studies has recently completed the construction of a new experimental facility to study hypervelocity dust impacts. The installation includes a 3 MV Pelletron, accelerating small particles in the size range of 0.1 to few microns to velocities in the range of 1 to 100 km/s. Here we report the capabilities of our facility, and the results of our first experiments.

  8. Research and test facilities

    NASA Technical Reports Server (NTRS)

    1993-01-01

    A description is given of each of the following Langley research and test facilities: 0.3-Meter Transonic Cryogenic Tunnel, 7-by 10-Foot High Speed Tunnel, 8-Foot Transonic Pressure Tunnel, 13-Inch Magnetic Suspension & Balance System, 14-by 22-Foot Subsonic Tunnel, 16-Foot Transonic Tunnel, 16-by 24-Inch Water Tunnel, 20-Foot Vertical Spin Tunnel, 30-by 60-Foot Wind Tunnel, Advanced Civil Transport Simulator (ACTS), Advanced Technology Research Laboratory, Aerospace Controls Research Laboratory (ACRL), Aerothermal Loads Complex, Aircraft Landing Dynamics Facility (ALDF), Avionics Integration Research Laboratory, Basic Aerodynamics Research Tunnel (BART), Compact Range Test Facility, Differential Maneuvering Simulator (DMS), Enhanced/Synthetic Vision & Spatial Displays Laboratory, Experimental Test Range (ETR) Flight Research Facility, General Aviation Simulator (GAS), High Intensity Radiated Fields Facility, Human Engineering Methods Laboratory, Hypersonic Facilities Complex, Impact Dynamics Research Facility, Jet Noise Laboratory & Anechoic Jet Facility, Light Alloy Laboratory, Low Frequency Antenna Test Facility, Low Turbulence Pressure Tunnel, Mechanics of Metals Laboratory, National Transonic Facility (NTF), NDE Research Laboratory, Polymers & Composites Laboratory, Pyrotechnic Test Facility, Quiet Flow Facility, Robotics Facilities, Scientific Visualization System, Scramjet Test Complex, Space Materials Research Laboratory, Space Simulation & Environmental Test Complex, Structural Dynamics Research Laboratory, Structural Dynamics Test Beds, Structures & Materials Research Laboratory, Supersonic Low Disturbance Pilot Tunnel, Thermal Acoustic Fatigue Apparatus (TAFA), Transonic Dynamics Tunnel (TDT), Transport Systems Research Vehicle, Unitary Plan Wind Tunnel, and the Visual Motion Simulator (VMS).

  9. 40. 500,000 POUND STATIC TEST FACILITY: DISTANT VIEW WITH BLOCKHOUSE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    40. 500,000 POUND STATIC TEST FACILITY: DISTANT VIEW WITH BLOCKHOUSE IN FOREGROUND, LOOKING SOUTHEAST - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  10. Systematic Review of Multidisciplinary Chronic Pain Treatment Facilities

    PubMed Central

    Fashler, Samantha R.; Cooper, Lynn K.; Oosenbrug, Eric D.; Burns, Lindsay C.; Razavi, Shima; Goldberg, Lauren; Katz, Joel

    2016-01-01

    This study reviewed the published literature evaluating multidisciplinary chronic pain treatment facilities to provide an overview of their availability, caseload, wait times, and facility characteristics. A systematic literature review was conducted using PRISMA guidelines following a search of MEDLINE, PsycINFO, and CINAHL databases. Inclusion criteria stipulated that studies be original research, survey more than one pain treatment facility directly, and describe a range of available treatments. Fourteen articles satisfied inclusion criteria. Results showed little consistency in the research design used to describe pain treatment facilities. Availability of pain treatment facilities was scarce and the reported caseloads and wait times were generally high. A wide range of medical, physical, and psychological pain treatments were available. Most studies reported findings on the percentage of practitioners in different health care professions employed. Future studies should consider using more comprehensive search strategies to survey facilities, improving clarity on what is considered to be a pain treatment facility, and reporting on a consistent set of variables to provide a clear summary of the status of pain treatment facilities. This review highlights important information for policymakers on the scope, demand, and accessibility of pain treatment facilities. PMID:27445618

  11. Blood Pressure Levels and Mortality Risk among Hemodialysis Patients: Results from the Dialysis Outcomes and Practice Patterns Study

    PubMed Central

    Robinson, Bruce M.; Tong, Lin; Zhang, Jinyao; Wolfe, Robert A.; Goodkin, David A.; Greenwood, Roger N.; Kerr, Peter G.; Morgenstern, Hal; Li, Yun; Pisoni, Ronald L.; Saran, Rajiv; Tentori, Francesca; Akizawa, Tadao; Fukuhara, Shunichi; Port, Friedrich K.

    2014-01-01

    KDOQI practice guidelines recommend pre-dialysis blood pressure (BP) <140/90 mm Hg. However, most prior hemodialysis studies found elevated mortality with low, not high, systolic blood pressure (SBP), possibly due to unmeasured confounders affecting BP and mortality such as severity of comorbidities. To lessen this bias, we analyzed facility-level BP practices, relating patient-level survival to the fraction of patients in BP categories at each dialysis facility in Cox regression models adjusted for patient and facility characteristics. Analyses included 24,525 patients in the Dialysis Outcomes and Practice Patterns Study. Compared with pre-dialysis SBP 130–159 mm Hg, mortality was 13% higher in facilities with 20% more patients at SBP 110–129 mm Hg and 16% higher in facilities with 20% more patients at SBP ≥160 mm Hg. For patient-level SBP, mortality was elevated at low (<130 mm Hg), not high (up to ≥180 mm Hg) SBP. For pre-dialysis diastolic BP, mortality was lowest at 60–99 mm Hg, a wide range suggesting less chance to improve outcomes. Higher mortality at SBP <130 mm Hg is consistent with prior studies and may be due to excessive BP-lowering during dialysis. The lowest risk facility SBP range of 130–159 mm Hg indicates this range may be optimal, but may have been influenced by unmeasured facility practices. While additional study is needed, the findings contrast with KDOQI BP targets, and provide guidance on optimal BP range in absence of definitive clinical trial data. PMID:22718187

  12. Long Range Facilities Master Plan: 1986-2000, San Diego Unified School District.

    ERIC Educational Resources Information Center

    Blair, Billie; And Others

    The Long-Range Facilities Master Plan presents solution strategies and financing methods for accommodating a projected student enrollment increase of 45,000 between 1986 and 2000. This increase, plus limited financial resources, school use studies, and recent legislation, necessitated the plan. The issues include housing students, facility…

  13. Major Range and Test Facility Base Summary of Capabilities.

    DTIC Science & Technology

    1983-06-01

    TEST CHART NATIONAL BUREAU OF STANDARDS 1963 A 3,i 4, S °.I i L -. ~ . % o,. ° . - ° . - . .I ¢ PHOTOGRAPH THIS SHEET LEVEL INVENTORY DOCUMENT...NUMBER DOD 3200.11-D 4. TTLE(~dS..tt~t@) S TYPE Of REPORT a PERIO’ COVERED Major Range and Test Facility Base Summary Reference Maerial of Capabilities...Electronic Warfare, Command, Control Communications and Intelligence (C31) Surveillance, Jammers, Radar, Test Facility ZG5 ABETW ACT f~ a "Afie Afr- s 444 eF~f

  14. 38. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST BAY AND EXHAUST PIT, LOOKING WEST - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  15. 37. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST BAY AND EXHAUST PIT, LOOKING SOUTHWEST - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  16. Data Acquisition System Architecture and Capabilities At NASA GRC Plum Brook Station's Space Environment Test Facilities

    NASA Technical Reports Server (NTRS)

    Evans, Richard K.; Hill, Gerald M.

    2012-01-01

    Very large space environment test facilities present unique engineering challenges in the design of facility data systems. Data systems of this scale must be versatile enough to meet the wide range of data acquisition and measurement requirements from a diverse set of customers and test programs, but also must minimize design changes to maintain reliability and serviceability. This paper presents an overview of the common architecture and capabilities of the facility data acquisition systems available at two of the world?s largest space environment test facilities located at the NASA Glenn Research Center?s Plum Brook Station in Sandusky, Ohio; namely, the Space Propulsion Research Facility (commonly known as the B-2 facility) and the Space Power Facility (SPF). The common architecture of the data systems is presented along with details on system scalability and efficient measurement systems analysis and verification. The architecture highlights a modular design, which utilizes fully-remotely managed components, enabling the data systems to be highly configurable and support multiple test locations with a wide-range of measurement types and very large system channel counts.

  17. Data Acquisition System Architecture and Capabilities at NASA GRC Plum Brook Station's Space Environment Test Facilities

    NASA Technical Reports Server (NTRS)

    Evans, Richard K.; Hill, Gerald M.

    2014-01-01

    Very large space environment test facilities present unique engineering challenges in the design of facility data systems. Data systems of this scale must be versatile enough to meet the wide range of data acquisition and measurement requirements from a diverse set of customers and test programs, but also must minimize design changes to maintain reliability and serviceability. This paper presents an overview of the common architecture and capabilities of the facility data acquisition systems available at two of the world's largest space environment test facilities located at the NASA Glenn Research Center's Plum Brook Station in Sandusky, Ohio; namely, the Space Propulsion Research Facility (commonly known as the B-2 facility) and the Space Power Facility (SPF). The common architecture of the data systems is presented along with details on system scalability and efficient measurement systems analysis and verification. The architecture highlights a modular design, which utilizes fully-remotely managed components, enabling the data systems to be highly configurable and support multiple test locations with a wide-range of measurement types and very large system channel counts.

  18. Evaluation of the antipsychotic medication review process at four long-term facilities in Alberta.

    PubMed

    Birney, Arden; Charland, Paola; Cole, Mollie; Aslam Arain, Mubashir

    2016-01-01

    The goal of this evaluation was to understand how four long-term care (LTC) facilities in Alberta have implemented medication reviews for the Appropriate Use of Antipsychotics (AUA) initiative. We aimed to determine how interprofessional (IP) collaboration was incorporated in the antipsychotic medication reviews and how the reviews had been sustained. Four LTC facilities in Alberta participated in this evaluation. We conducted semistructured interviews with 18 facility staff and observed one antipsychotic medication review at each facility. We analyzed data according to the following key components that we identified as relevant to the antipsychotic medication reviews: the structure of the reviews, IP interactions between the staff members, and strategies for sustaining the reviews. The duration of antipsychotic medication reviews ranged from 1 to 1.5 hours. The number of professions in attendance ranged from 3 to 9; a pharmacist led the review at two sites, while a registered nurse led the review at one site and a nurse practitioner at the remaining site. The number of residents discussed during the review ranged from 6 to 20. The process at some facilities was highly IP, demonstrating each of the six IP competencies. Other facilities conducted the review in a less IP manner due to challenges of physician involvement and staff workload, particularly of health care aides. Facilities that had an nurse practitioner on site were more efficient with the process of implementing recommendations resulting from the medication reviews. The LTC facilities were successful in implementing the medication review process and the process seemed to be sustainable. A few challenges were observed in the implementation process at two facilities. IP practice moved forward the goals of the AUA initiative to reduce the inappropriate use of antipsychotics.

  19. Shock Tube and Ballistic Range Facilities at NASA Ames Research Center

    NASA Technical Reports Server (NTRS)

    Grinstead, Jay H.; Wilder, Michael C.; Reda, Daniel C.; Cornelison, Charles J.; Cruden, Brett A.; Bogdanoff, David W.

    2010-01-01

    The Electric Arc Shock Tube (EAST) facility and the Hypervelocity Free Flight Aerodynamic Facility (HFFAF) at NASA Ames Research Center are described. These facilities have been in operation since the 1960s and have supported many NASA missions and technology development initiatives. The facilities have world-unique capabilities that enable experimental studies of real-gas aerothermal, gas dynamic, and kinetic phenomena of atmospheric entry.

  20. 34. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF BLOCKHOUSE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF BLOCKHOUSE AND TOP OF TEST BAY, LOOKING NORTHEAST - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  1. 33. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF BLOCKHOUSE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF BLOCKHOUSE AND UPPER LEVEL OF TEST BAY, LOOKING NORTH - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  2. 51. 500,000 POUND STATIC TEST FACILITY: CLOSEUP VIEW FROM EAST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    51. 500,000 POUND STATIC TEST FACILITY: CLOSE-UP VIEW FROM EAST SHOWING MOVABLE OBSERVATION MIRRORS WITH TRACKS - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  3. Evaluating and understanding fish health risks and their consequences in propagated and free-ranging fish populations

    USGS Publications Warehouse

    Moffitt, C.M.; Haukenes, A.H.; Williams, C.J.

    2005-01-01

    Fishery managers and resource conservationists are increasingly interested in understanding the fish health and disease risks of free-ranging fishes and whether propagated fishes or features and practices used at fish culture facilities pose a health risk to free-ranging populations. Disease agents are present in most both captive and all free-ranging fish populations, but the consequences and extent of infections in free-ranging populations are often difficult to measure, control, and understand. Sampling methods, protocols, and assay techniques developed to assess the health of captive populations are not as applicable for assessments of free-ranging fishes. The use of chemicals and therapeutics to control diseases and parasites in propagated fishes likely reduces the risk of introducing specific pathogens into the environment, but control measures may have localized effects on the environment surrounding fish culture facilities. To understand health risks of propagated and free ranging fishes, we must consider fish populations, culture facilities, fish releases, and their interactions within the greater geospatial features of the aquatic environment. ?? 2004 by the American Fisheries Society.

  4. Environmental Assessment for the Blair Lakes Bombing Range Facility Improvements

    DTIC Science & Technology

    2006-03-01

    None of these sites would be impacted by range activities. In the event that historic or cultura l sites are discovered during range construction or...willow. These areas often contain seasonally persistent water bodies. Along stream courses (Willow and Dry Creek, and tributaries ) soils are...The only identified fish stream in the immediate facility area is an unnamed tributary of Clear Creek. The ADF&G has catalogued this stream as

  5. Wallops: The Management of Rapid Change

    NASA Technical Reports Server (NTRS)

    Kremer, Steven E.

    2016-01-01

    A unique national resource, Wallops Flight Facility's Research Range enables flexible, low-cost space access, in-flight science, and technology research for all of NASA and the nation. It is the only launch range that NASA owns. This is for Keynote Address and charts are primarily an overview of activities performed at Wallops Flight Facility.

  6. A research study for the preliminary definition of an aerophysics free-flight laboratory facility

    NASA Technical Reports Server (NTRS)

    Canning, Thomas N.

    1988-01-01

    A renewed interest in hypervelocity vehicles requires an increase in the knowledge of aerodynamic phenomena. Tests conducted with ground-based facilities can be used both to better understand the physics of hypervelocity flight, and to calibrate and validate computer codes designed to predict vehicle performance in the hypervelocity environment. This research reviews the requirements for aerothermodynamic testing and discusses the ballistic range and its capabilities. Examples of the kinds of testing performed in typical high performance ballistic ranges are described. We draw heavily on experience obtained in the ballistics facilities at NASA Ames Research Center, Moffett Field, California. Prospects for improving the capabilities of the ballistic range by using advanced instrumentation are discussed. Finally, recent developments in gun technology and their application to extend the capability of the ballistic range are summarized.

  7. Overview of the NASA Dryden Flight Research Facility aeronautical flight projects

    NASA Technical Reports Server (NTRS)

    Meyer, Robert R., Jr.

    1992-01-01

    Several principal aerodynamics flight projects of the NASA Dryden Flight Research Facility are discussed. Key vehicle technology areas from a wide range of flight vehicles are highlighted. These areas include flight research data obtained for ground facility and computation correlation, applied research in areas not well suited to ground facilities (wind tunnels), and concept demonstration.

  8. Survey of aircraft icing simulation test facilities in North America

    NASA Technical Reports Server (NTRS)

    Olsen, W.

    1981-01-01

    A survey was made of the aircraft icing simulation facilities in North America: there are 12 wind tunnels, 28 engine test facilities, 6 aircraft tankers and 14 low velocity facilities, that perform aircraft icing tests full or part time. The location and size of the facility, its speed and temperature range, icing cloud parameters, and the technical person to contact are surveyed. Results are presented in tabular form. The capabilities of each facility were estimated by its technical contact person. The adequacy of these facilities for various types of icing tests is discussed.

  9. Engine component instrumentation development facility at NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Bruckner, Robert J.; Buggele, Alvin E.; Lepicovsky, Jan

    1992-01-01

    The Engine Components Instrumentation Development Facility at NASA Lewis is a unique aeronautics facility dedicated to the development of innovative instrumentation for turbine engine component testing. Containing two separate wind tunnels, the facility is capable of simulating many flow conditions found in most turbine engine components. This facility's broad range of capabilities as well as its versatility provide an excellent location for the development of novel testing techniques. These capabilities thus allow a more efficient use of larger and more complex engine component test facilities.

  10. Review of national association of city transportation officials (NACTO) bicycle facilities.

    DOT National Transportation Integrated Search

    2012-04-06

    As bicycle facilities are installed on more streets in more cities across the country, innovative solutions have been introduced into the toolbox of facilities to address a wide range of contexts and serve bicyclists of all ages and abilities. These ...

  11. Emissions of PCDD and PCDF from combustion of forest fuels and sugarcane: a comparison between field measurements and simulations in a laboratory burn facility.

    PubMed

    Black, R R; Meyer, C P; Touati, A; Gullett, B K; Fiedler, H; Mueller, J F

    2011-05-01

    Release of PCDD and PCDF from biomass combustion such as forest and agricultural crop fires has been nominated as an important source for these chemicals despite minimal characterisation. Available emission factors that have been experimentally determined in laboratory and field experiments vary by several orders of magnitude from <0.5 μg TEQ (t fuel consumed)(-1) to >100 μg TEQ (t fuel consumed)(-1). The aim of this study was to evaluate the effect of experimental methods on the emission factor. A portable field sampler was used to measure PCDD/PCDF emissions from forest fires and the same fuel when burnt over a brick hearth to eliminate potential soil effects. A laboratory burn facility was used to sample emissions from the same fuels. There was very good agreement in emission factors to air (EF(Air)) for forest fuel (Duke Forest, NC) of 0.52 (range: 0.40-0.79), 0.59 (range: 0.18-1.2) and 0.75 (range: 0.27-1.2) μg TEQ(WHO2005) (t fuel consumed)(-1) for the in-field, over a brick hearth, and burn facility experiments, respectively. Similarly, experiments with sugarcane showed very good agreement with EF(Air) of 1.1 (range: 0.40-2.2), 1.5 (range: 0.84-2.2) and 1.7 (range: 0.34-4.4) μg TEQ (t fuel consumed)(-1) for in-field, over a brick hearth, open field and burn facility experiments respectively. Field sampling and laboratory simulations were in good agreement, and no significant changes in emissions of PCDD/PCDF could be attributed to fuel storage and transport to laboratory test facilities. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Space technology test facilities at the NASA Ames Research Center

    NASA Technical Reports Server (NTRS)

    Gross, Anthony R.; Rodrigues, Annette T.

    1990-01-01

    The major space research and technology test facilities at the NASA Ames Research Center are divided into five categories: General Purpose, Life Support, Computer-Based Simulation, High Energy, and the Space Exploraton Test Facilities. The paper discusses selected facilities within each of the five categories and discusses some of the major programs in which these facilities have been involved. Special attention is given to the 20-G Man-Rated Centrifuge, the Human Research Facility, the Plant Crop Growth Facility, the Numerical Aerodynamic Simulation Facility, the Arc-Jet Complex and Hypersonic Test Facility, the Infrared Detector and Cryogenic Test Facility, and the Mars Wind Tunnel. Each facility is described along with its objectives, test parameter ranges, and major current programs and applications.

  13. Impact of Family Planning and Business Trainings on Private-Sector Health Care Providers in Nigeria.

    PubMed

    Ugaz, Jorge; Leegwater, Anthony; Chatterji, Minki; Johnson, Doug; Baruwa, Sikiru; Toriola, Modupe; Kinnan, Cynthia

    2017-06-01

    Private health care providers are an important source of modern contraceptives in Sub-Saharan Africa, yet they face many challenges that might be addressed through targeted training. This study measures the impact of a package of trainings and supportive supervision activities targeted to private health care providers in Lagos State, Nigeria, on outcomes including range of contraceptive methods offered, providers' knowledge and quality of counseling, recordkeeping practices, access to credit and revenue. A total of 965 health care facilities were randomly assigned to treatment and control groups. Facilities in the treatment group-but not those in the control group-were offered a training package that included a contraceptive technology update and interventions to improve counseling and clinical skills and business practices. Multivariate regression analysis of data collected through facility and mystery client surveys was used to estimate effects. The training program had a positive effect on the range of contraceptive methods offered, with facilities in the treatment group providing more methods than facilities in the control group. The training program also had a positive impact on the quality of counseling services, especially on the range of contraceptive methods discussed by providers, their interpersonal skills and overall knowledge. Facilities in the treatment group were more likely than facilities in the control group to have good recordkeeping practices and to have obtained loans. No effect was found on revenue generation. Targeted training programs can be effective tools to improve the provision of family planning services through private providers.

  14. Station report on the Goddard Space Flight Center (GSFC) 1.2 meter telescope facility

    NASA Technical Reports Server (NTRS)

    Mcgarry, Jan F.; Zagwodzki, Thomas W.; Abbott, Arnold; Degnan, John J.; Cheek, Jack W.; Chabot, Richard S.; Grolemund, David A.; Fitzgerald, Jim D.

    1993-01-01

    The 1.2 meter telescope system was built for the Goddard Space Flight Center (GSFC) in 1973-74 by the Kollmorgen Corporation as a highly accurate tracking telescope. The telescope is an azimuth-elevation mounted six mirror Coude system. The facility has been used for a wide range of experimentation including helioseismology, two color refractometry, lunar laser ranging, satellite laser ranging, visual tracking of rocket launches, and most recently satellite and aircraft streak camera work. The telescope is a multi-user facility housed in a two story dome with the telescope located on the second floor above the experimenter's area. Up to six experiments can be accommodated at a given time, with actual use of the telescope being determined by the location of the final Coude mirror. The telescope facility is currently one of the primary test sites for the Crustal Dynamics Network's new UNIX based telescope controller software, and is also the site of the joint Crustal Dynamics Project / Photonics Branch two color research into atmospheric refraction.

  15. Advanced Spectroscopic and Thermal Imaging Instrumentation for Shock Tube and Ballistic Range Facilities

    NASA Technical Reports Server (NTRS)

    Grinstead, Jay H.; Wilder, Michael C.; Reda, Daniel C.; Cruden, Brett A.; Bogdanoff, David W.

    2010-01-01

    The Electric Arc Shock Tube (EAST) facility and Hypervelocity Free Flight Aerodynamic Facility (HFFAF, an aeroballistic range) at NASA Ames support basic research in aerothermodynamic phenomena of atmospheric entry, specifically shock layer radiation spectroscopy, convective and radiative heat transfer, and transition to turbulence. Innovative optical instrumentation has been developed and implemented to meet the challenges posed from obtaining such data in these impulse facilities. Spatially and spectrally resolved measurements of absolute radiance of a travelling shock wave in EAST are acquired using multiplexed, time-gated imaging spectrographs. Nearly complete spectral coverage from the vacuum ultraviolet to the near infrared is possible in a single experiment. Time-gated thermal imaging of ballistic range models in flight enables quantitative, global measurements of surface temperature. These images can be interpreted to determine convective heat transfer rates and reveal transition to turbulence due to isolated and distributed surface roughness at hypersonic velocities. The focus of this paper is a detailed description of the optical instrumentation currently in use in the EAST and HFFAF.

  16. Site and Facilities: A Resource Book for Camps.

    ERIC Educational Resources Information Center

    Ball, Armand, Ed.; Ball, Beverly, Ed.

    This resource book draws together articles on the development and maintenance of camp sites and facilities. The articles, previously published by "Camping Magazine" and "Journal of Christian Camping," cover (1) site planning and long-range development, including redesigning multiple camp facilities for year-round programs, remodeling and…

  17. DOE passive solar commercial buildings program: project summaries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1982-01-01

    The 23 projects participating in this program comprise a wide range of building types including offices, retail establishments, educational facilities, public service facilities, community and visitor centers, and private specialized-use facilities, located throughout the United States. Summary data and drawings are presented for each project. (MHR)

  18. 2014 Annual Report - Argonne Leadership Computing Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collins, James R.; Papka, Michael E.; Cerny, Beth A.

    The Argonne Leadership Computing Facility provides supercomputing capabilities to the scientific and engineering community to advance fundamental discovery and understanding in a broad range of disciplines.

  19. 2015 Annual Report - Argonne Leadership Computing Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collins, James R.; Papka, Michael E.; Cerny, Beth A.

    The Argonne Leadership Computing Facility provides supercomputing capabilities to the scientific and engineering community to advance fundamental discovery and understanding in a broad range of disciplines.

  20. The Wallops Flight Facility Model for an Integrated Federal/Commercial Launch Range

    NASA Technical Reports Server (NTRS)

    Underwood, Bruce E.

    1999-01-01

    Historically, the federal government has been the predominant purchaser of space launches in the United States. The government met its needs through purchase of hardware and services. It also provided the infrastructure necessary to conduct launch operations through federal launch ranges, both military and NASA. Under this model, the government had the complete ownership, responsibility, liability, and expense for launch activities. As the commercial space sector grew, there emerged a corresponding growth in demand for launch range services. However, the expense and complexity of activities has thus far deterred a rapid rise in the establishment of purely commercial launch sites. In this context, purely commercial is defined as "without benefit of capabilities provided by the federal government." Consistent with the Commercial Space Launch Act, in recent years NASA and the Air Force have supported commercial launches from government launch ranges on a cost-reimbursable, non-interference basis. In this mode the commercial launch service providers contract with the government to provide services including use of facilities, tracking and data services, and range safety. As the commercial market projections began to show significant opportunities for economic development, several states established spaceports to provide the services necessary to meet these projected commercial needs. In 1997, NASA agreed to the establishment of the Virginia Space Flight Center (VSFC) at the Wallops Flight Facility. Under this arrangement, NASA agreed to allow Virginia Commercial Space Flight Authority (VCSFA) to construct facilities on NASA property and agreed to provide services in accordance with the Space Act of 1958 and the Commercial Space Launch Act of 1984 (as amended) to support VSFC launch customers. The relationship between NASA and VCSFA, however, has evolved beyond a customer supplier relationship. A partnership relationship has emerged which pairs the strengths of the established NASA test range and the state-sponsored, commercial launch facility provider, in an attempt to satisfy the needs for flexible, low-cost access to space. Furthermore, the future of the NASA/Wallops Test Range is closely linked with the success of VCSFA in promoting commercial launches from Wallops. This paper will describe the changing paradigm of the federal launch range and the unique aspects of the NASA/Wallops Facility relationship with VCSFA. Discussion will include institutional cost-sharing, business development and marketing, joint educational programs, and strategic planning.

  1. Experimental forests and ranges. Field research facilities of the Pacific Southwest Research Station.

    Treesearch

    Neil H. Berg

    1990-01-01

    The 10 experimental forests and ranges in California administered by the Pacific Southwest Research Station, Forest Service, U.S. Department of Agriculture, are described. The purposes of these facilities, and how to request their use for approved scientific study are given, and the natural resource base, data bases, studies, and general features of each are also...

  2. Finding of No Significant Impact and Finding of No Practicable Aleternative for the Environmental Assessment for the 21 Point Enclosed Firing Range at Joint-Base Andrews-Naval Air Facility Washington, Maryland

    DTIC Science & Technology

    2015-03-02

    Corps of Engineers Joint Base Andrews-Naval Air Facility Final EA – Firing Range October 2014 v WSSC Washington Suburban Sanitary Commission...are leaving the site with waste residue still on their skin and uniforms. Per section 7.6.1.7 [Latrines ( Sanitary Facilities)] in ETL 11-18 (Small...served by water, sanitary sewer, and power. A fire hydrant exists on the site, while another hydrant exists at the intersection of the entry road and

  3. Goldsboro City Schools Comprehensive Survey 1988-89.

    ERIC Educational Resources Information Center

    North Carolina State Dept. of Public Instruction, Raleigh. Div. of School Planning.

    This report presents results of a comprehensive survey of the Goldsboro (North Carolina) City School System conducted during the 1988-89 school year. The purpose of the survey was to determine long-range planning implications for the areas of organization, facility utilization, facility needs, site development, and media facilities. The report is…

  4. The Diesel Exhaust in Miners Study: II. Exposure monitoring surveys and development of exposure groups.

    PubMed

    Coble, Joseph B; Stewart, Patricia A; Vermeulen, Roel; Yereb, Daniel; Stanevich, Rebecca; Blair, Aaron; Silverman, Debra T; Attfield, Michael

    2010-10-01

    Air monitoring surveys were conducted between 1998 and 2001 at seven non-metal mining facilities to assess exposure to respirable elemental carbon (REC), a component of diesel exhaust (DE), for an epidemiologic study of miners exposed to DE. Personal exposure measurements were taken on workers in a cross-section of jobs located underground and on the surface. Air samples taken to measure REC were also analyzed for respirable organic carbon (ROC). Concurrent measurements to assess exposure to nitric oxide (NO) and nitrogen dioxide (NO₂), two gaseous components of DE, were also taken. The REC measurements were used to develop quantitative estimates of average exposure levels by facility, department, and job title for the epidemiologic analysis. Each underground job was assigned to one of three sets of exposure groups from specific to general: (i) standardized job titles, (ii) groups of standardized job titles combined based on the percentage of time in the major underground areas, and (iii) larger groups based on similar area carbon monoxide (CO) air concentrations. Surface jobs were categorized based on their use of diesel equipment and proximity to DE. A total of 779 full-shift personal measurements were taken underground. The average REC exposure levels for underground jobs with five or more measurements ranged from 31 to 58 μg m⁻³ at the facility with the lowest average exposure levels and from 313 to 488 μg m⁻³ at the facility with the highest average exposure levels. The average REC exposure levels for surface workers ranged from 2 to 6 μg m⁻³ across the seven facilities. There was much less contrast in the ROC compared with REC exposure levels measured between surface and underground workers within each facility, as well as across the facilities. The average ROC levels underground ranged from 64 to 195 μg m⁻³, while on the surface, the average ROC levels ranged from 38 to 71 μg m⁻³ by facility, an ∼2- to 3-fold difference. The average NO and NO₂ levels underground ranged from 0.20 to 1.49 parts per million (ppm) and from 0.10 to 0.60 ppm, respectively, and were ∼10 times higher than levels on the surface, which ranged from 0.02 to 0.11 ppm and from 0.01 to 0.06 ppm, respectively. The ROC, NO, and NO₂ concentrations underground were correlated with the REC levels (r = 0.62, 0.71, and 0.62, respectively). A total of 80% of the underground jobs were assigned an exposure estimate based on measurements taken for the specific job title or for other jobs with a similar percentage of time spent in the major underground work areas. The average REC exposure levels by facility were from 15 to 64 times higher underground than on the surface. The large contrast in exposure levels measured underground versus on the surface, along with the differences between the mining facilities and between underground jobs within the facilities resulted in a wide distribution in the exposure estimates for evaluation of exposure-response relationships in the epidemiologic analyses.

  5. The Diesel Exhaust in Miners Study: II. Exposure Monitoring Surveys and Development of Exposure Groups

    PubMed Central

    Coble, Joseph B.; Stewart, Patricia A.; Vermeulen, Roel; Yereb, Daniel; Stanevich, Rebecca; Blair, Aaron; Silverman, Debra T.; Attfield, Michael

    2010-01-01

    Air monitoring surveys were conducted between 1998 and 2001 at seven non-metal mining facilities to assess exposure to respirable elemental carbon (REC), a component of diesel exhaust (DE), for an epidemiologic study of miners exposed to DE. Personal exposure measurements were taken on workers in a cross-section of jobs located underground and on the surface. Air samples taken to measure REC were also analyzed for respirable organic carbon (ROC). Concurrent measurements to assess exposure to nitric oxide (NO) and nitrogen dioxide (NO2), two gaseous components of DE, were also taken. The REC measurements were used to develop quantitative estimates of average exposure levels by facility, department, and job title for the epidemiologic analysis. Each underground job was assigned to one of three sets of exposure groups from specific to general: (i) standardized job titles, (ii) groups of standardized job titles combined based on the percentage of time in the major underground areas, and (iii) larger groups based on similar area carbon monoxide (CO) air concentrations. Surface jobs were categorized based on their use of diesel equipment and proximity to DE. A total of 779 full-shift personal measurements were taken underground. The average REC exposure levels for underground jobs with five or more measurements ranged from 31 to 58 μg m−3 at the facility with the lowest average exposure levels and from 313 to 488 μg m−3 at the facility with the highest average exposure levels. The average REC exposure levels for surface workers ranged from 2 to 6 μg m−3 across the seven facilities. There was much less contrast in the ROC compared with REC exposure levels measured between surface and underground workers within each facility, as well as across the facilities. The average ROC levels underground ranged from 64 to 195 μg m−3, while on the surface, the average ROC levels ranged from 38 to 71 μg m−3 by facility, an ∼2- to 3-fold difference. The average NO and NO2 levels underground ranged from 0.20 to 1.49 parts per million (ppm) and from 0.10 to 0.60 ppm, respectively, and were ∼10 times higher than levels on the surface, which ranged from 0.02 to 0.11 ppm and from 0.01 to 0.06 ppm, respectively. The ROC, NO, and NO2 concentrations underground were correlated with the REC levels (r = 0.62, 0.71, and 0.62, respectively). A total of 80% of the underground jobs were assigned an exposure estimate based on measurements taken for the specific job title or for other jobs with a similar percentage of time spent in the major underground work areas. The average REC exposure levels by facility were from 15 to 64 times higher underground than on the surface. The large contrast in exposure levels measured underground versus on the surface, along with the differences between the mining facilities and between underground jobs within the facilities resulted in a wide distribution in the exposure estimates for evaluation of exposure–response relationships in the epidemiologic analyses. PMID:20876232

  6. Using the NPSS Environment to Model an Altitude Test Facility

    NASA Technical Reports Server (NTRS)

    Lavelle, Thomas M.; Owen, Albert K.; Huffman, Brian C.

    2013-01-01

    An altitude test facility was modeled using Numerical Propulsion System Simulation (NPSS). This altitude test facility model represents the most detailed facility model developed in the NPSS architecture. The current paper demonstrates the use of the NPSS system to define the required operating range of a component for the facility. A significant number of additional component models were easily developed to complete the model. Discussed in this paper are the additional components developed and what was done in the development of these components.

  7. The Saucer Ride

    NASA Image and Video Library

    2015-05-11

    Crews from the Columbia Scientific Balloon Facility prepare the balloon for flight for the 2014 NASA Low-Density Supersonic Decelerator test from the U.S. Navy Pacific Missile Range Facility on Kauai, Hawaii.

  8. Automated Heat-Flux-Calibration Facility

    NASA Technical Reports Server (NTRS)

    Liebert, Curt H.; Weikle, Donald H.

    1989-01-01

    Computer control speeds operation of equipment and processing of measurements. New heat-flux-calibration facility developed at Lewis Research Center. Used for fast-transient heat-transfer testing, durability testing, and calibration of heat-flux gauges. Calibrations performed at constant or transient heat fluxes ranging from 1 to 6 MW/m2 and at temperatures ranging from 80 K to melting temperatures of most materials. Facility developed because there is need to build and calibrate very-small heat-flux gauges for Space Shuttle main engine (SSME).Includes lamp head attached to side of service module, an argon-gas-recirculation module, reflector, heat exchanger, and high-speed positioning system. This type of automated heat-flux calibration facility installed in industrial plants for onsite calibration of heat-flux gauges measuring fluxes of heat in advanced gas-turbine and rocket engines.

  9. Laser shock compression experiments on precompressed water in ``SG-II'' laser facility

    NASA Astrophysics Data System (ADS)

    Shu, Hua; Huang, Xiuguang; Ye, Junjian; Fu, Sizu

    2017-06-01

    Laser shock compression experiments on precompressed samples offer the possibility to obtain new hugoniot data over a significantly broader range of density-temperature phase than was previously achievable. This technique was developed in ``SG-II'' laser facility. Hugoniot data were obtained for water in 300 GPa pressure range by laser-driven shock compression of samples statically precompressed in diamond-anvil cells.

  10. Variations in status of preparation of personal protective equipment for preventing norovirus gastroenteritis in long-term care facilities for the elderly.

    PubMed

    Fujiki, Saori; Ishizaki, Tatsuro; Nakayama, Takeo

    2017-12-01

    Residents of long-term care facilities are highly susceptible to norovirus gastroenteritis, and each facility is concerned about the need to implement norovirus infection control. Among control measures, personal protective equipment (PPE), such as disposable gloves and masks, plays a major role in reducing infectious spread. However, the preparation status of PPE in facilities before infection outbreaks has not been reported. The aim was to clarify the implementation status of preventive measures for norovirus gastroenteritis and the cost of preparing the necessary PPE in long-term care facilities. A questionnaire survey of facilities affiliated with the Kyoto Prefecture and Osaka Prefecture branches of the Japan Association of Geriatric Health Services Facilities was conducted. The survey items were the characteristics of the facility, whether preventive measures had been implemented for norovirus gastroenteritis from October through the following March in both 2009 and 2010, and the quantities and unit prices of PPE prepared for preventive measures. Twenty-six (11.2%) of 232 surveyed facilities (as of August 2011) answered the survey. Among them, 24 (92.3%) in 2009 and 25 (96.2%) in 2010 reported having implemented preventive measures for norovirus gastroenteritis, while 21 facilities (80.8%) in 2009 and 22 facilities (84.6%) in 2010 had prepared PPE. The median total cost for preparing the PPE needed for the preventive measures was US $2601 (range US $221-9192) in 2009 and US $3904 (range US $305-6427) in 2010. Although the results need careful interpretation because of the low response rate, most of the surveyed long-term care facilities had implemented preventive measures for norovirus gastroenteritis. However, the cost of preparing the PPE needed for the preventive measures varied among the facilities. © 2017 John Wiley & Sons, Ltd.

  11. Proposed Capital Program 1970-1975, the School District of Philadelphia.

    ERIC Educational Resources Information Center

    Philadelphia School District, PA.

    This report presents the School District of Philadelphia's long-range plan for school facilities and, based upon it, a capital program for the fiscal years 1970 through 1975. Present conditions are reviewed, citing the "facility gap" and indicating future needs. The plan for school facilities is presented specifying--(1) the educational basis of…

  12. Facility Accessibility: Opening the Doors to All

    ERIC Educational Resources Information Center

    Petersen, Jeffrey C.; Piletic, Cindy K.

    2006-01-01

    A facility developed for fitness, physical activity, recreation, or sport is a vital community resource that contributes to the overall health and wellness of that community's citizens. In order to maximize the benefits derived from these facilities, it is imperative that they be accessible to as wide a range of people as possible. The Americans…

  13. A Bridge over Troubled Water: Facility Needs for Inclusive Classrooms.

    ERIC Educational Resources Information Center

    Pierce, Judy; And Others

    1993-01-01

    Focuses on ways to meet the facility needs of students with disabilities in inclusive classrooms. Provides a definition of inclusion; discusses some processes to design school environments that support a side range of student needs; and presents a process that will enable facility planning teams to move all students from self-contained classrooms…

  14. Complementary Aerodynamic Performance Datasets for Variable Speed Power Turbine Blade Section from Two Independent Transonic Turbine Cascades

    NASA Technical Reports Server (NTRS)

    Flegel, Ashlie B.; Welch, Gerard E.; Giel, Paul W.; Ames, Forrest E.; Long, Jonathon A.

    2015-01-01

    Two independent experimental studies were conducted in linear cascades on a scaled, two-dimensional mid-span section of a representative Variable Speed Power Turbine (VSPT) blade. The purpose of these studies was to assess the aerodynamic performance of the VSPT blade over large Reynolds number and incidence angle ranges. The influence of inlet turbulence intensity was also investigated. The tests were carried out in the NASA Glenn Research Center Transonic Turbine Blade Cascade Facility and at the University of North Dakota (UND) High Speed Compressible Flow Wind Tunnel Facility. A large database was developed by acquiring total pressure and exit angle surveys and blade loading data for ten incidence angles ranging from +15.8deg to -51.0deg. Data were acquired over six flow conditions with exit isentropic Reynolds number ranging from 0.05×106 to 2.12×106 and at exit Mach numbers of 0.72 (design) and 0.35. Flow conditions were examined within the respective facility constraints. The survey data were integrated to determine average exit total-pressure and flow angle. UND also acquired blade surface heat transfer data at two flow conditions across the entire incidence angle range aimed at quantifying transitional flow behavior on the blade. Comparisons of the aerodynamic datasets were made for three "match point" conditions. The blade loading data at the match point conditions show good agreement between the facilities. This report shows comparisons of other data and highlights the unique contributions of the two facilities. The datasets are being used to advance understanding of the aerodynamic challenges associated with maintaining efficient power turbine operation over a wide shaft-speed range.

  15. Development, application, and validation of a survey for infectious disease control practices at equine boarding facilities.

    PubMed

    Kirby, Alanna T; Traub-Dargatz, Josie L; Hill, Ashley E; Kogan, Lori R; Morley, Paul S; Heird, James C

    2010-11-15

    To develop a questionnaire for self-assessment of biosecurity practices at equine boarding facilities and to evaluate infectious disease control practices in these facilities in Colorado. Cross-sectional study. 64 equine boarding facilities in Colorado. Survey questions were rated according to importance for prevention and containment of equine infectious diseases. Point values (range, 0 to 20) were assigned for possible responses, with greater values given for optimal infection control methods. Questionnaires were mailed to equine boarding facilities in Colorado advertised on the World Wide Web. Survey responses were compared with assessments made by a member of the research team during visits to 30 randomly selected facilities. Agreement among results was analyzed via a kappa test and rated as poor, fair, moderate, substantial, or nearly perfect. Survey responses were received for 64 of 163 (39%) equine boarding facilities. Scores ranged from 106 to 402 points (maximum possible score, 418). Most facilities received better scores for movement and housing of equids than for other sections of the survey. Respondents at 24 of 48 (50%) facilities that routinely received new equids reported isolation of new arrivals. Agreement between self-assessment by survey respondents and evaluation by a member of the research team was determined to be fair to substantial. Most equine boarding facilities have opportunities to improve measures for prevention or containment of contagious diseases (eg, isolation of newly arrived equids and use of written health management protocols). Most self-assessments of infection control practices were accurate.

  16. Coverage of emergency obstetric care and availability of services in public and private health facilities in Bangladesh.

    PubMed

    Alam, Badrul; Mridha, Malay K; Biswas, Taposh K; Roy, Lumbini; Rahman, Maksudur; Chowdhury, Mahbub E

    2015-10-01

    To assess the coverage of emergency obstetric care (EmOC) and the availability of obstetric services in Bangladesh. In a national health facility assessment performed between November 2007 and July 2008, all public EmOC facilities and private facilities providing obstetric services in the 64 districts of Bangladesh were mapped. The performance of EmOC services in these facilities during the preceding month was investigated using a semi-structured questionnaire completed through interviews of managers and service providers, and record review. In total, 8.6 (2.1 public and 6.5 private) facilities per 500000 population offered obstetric care services. Population coverage by obstetric care facilities varied by region. Among 281 public facilities designated for comprehensive EmOC, cesarean delivery was available in only 215 (76.5%) and blood transfusion services in 198 (70.5%). In the private sector (for profit and not for profit), these services were available in more than 80% of facilities. In all facility types, performance of assisted vaginal delivery (range 12.2%-48.4%) and use of parenteral anticonvulsants to treat pre-eclampsia/eclampsia (range 48.6%-80.8%) were low. The main reason for non-availability of EmOC services was a lack of specialist/trained providers. Bangladesh needs to increase the availability of EmOC services through innovative public-private partnerships. In the public sector, additional trained manpower supported by an incentivized package should be deployed. Copyright © 2015. Published by Elsevier Ireland Ltd.

  17. A summary of existing and planned experiment hardware for low-gravity fluids research

    NASA Technical Reports Server (NTRS)

    Hill, Myron E.; O'Malley, Terence F.

    1991-01-01

    NASA's ground-based and space-based low-gravity facilities are summarized, and an overview of selected experiments that have been developed for use in these facilities is presented. A variety of ground-based facilities (drop towers and aircraft) used to conduct low-gravity experiments for in-space experimentation are described. Capabilities that are available to the researcher and future on-orbit fluids facilities are addressed. The payload bay facilities range from the completely self-contained, relatively small get-away-special canisters to the Materials Science Laboratory and to the larger Spacelab facilities that require crew interaction.

  18. Noise in animal facilities: why it matters.

    PubMed

    Turner, Jeremy G; Bauer, Carol A; Rybak, Leonard P

    2007-01-01

    Environmental noise can alter endocrine, reproductive and cardiovascular function, disturb sleep/wake cycles, and can mask normal communication between animals. These outcomes indicate that noise in the animal facility might have wide-ranging affects on animals, making what laboratory animals hear of consequence for all those who use animals in research, not just the hearing researcher. Given the wide-ranging effects of noise on laboratory animals, routine monitoring of noise in animal facilities would provide important information on the nature and stability of the animal environment. This special issue will highlight the need for more thorough monitoring and will serve as an introduction to noise and its various effects on animals.

  19. Western Aeronautical Test Range

    NASA Technical Reports Server (NTRS)

    Sakahara, Robert D.

    2008-01-01

    NASA's Western Aeronautical Test Range (WATR) is a network of facilities used to support aeronautical research, science missions, exploration system concepts, and space operations. The WATR resides at NASA's Dryden Flight Research Center located at Edwards Air Force Base, California. The WATR is a part of NASA's Corporate Management of Aeronautical Facilities and funded by the Strategic Capability Asset Program (SCAP). It is managed by the Aeronautics Test Program (ATP) of the Aeronautics Research Mission Directorate (ARMD) to provide the right facility at the right time. NASA is a tenant on Edwards Air Force Base and has an agreement with the Air Force Flight Test Center to use the land and airspace controlled by the Department of Defense (DoD). The topics include: 1) The WATR supports a variety of vehicles; 2) Dryden shares airspace with the AFFTC; 3) Restricted airspace, corridors, and special use areas are available for experimental aircraft; 4) WATR Products and Services; 5) WATR Support Configuration; 6) Telemetry Tracking; 7) Time Space Positioning; 8) Video; 9) Voice Communication; 10) Mobile Operations Facilities; 11) Data Processing; 12) Mission Control Center; 13) Real-Time Data Analysis; and 14) Range Safety.

  20. FME Carpentry Shop Keeps Facility in Good Repair | Poster

    Cancer.gov

    By Peggy Pearl, Contributing Writer Did you know that what most people call the Carpentry Shop at Facilities Maintenance and Engineering (FME) is actually made up of the three crafts, woodcrafting, painting, and locksmithing?  On any given day, throughout the Frederick National Laboratory campus, you may find shop staff utilizing an assortment of tools and a wide range of skills on projects ranging from simple maintenance to complete renovations.

  1. Role Of High Speed Photography In The Testing Capabilities Of The Arnold Engineering Development Center (AEDC) Range And Track Facilities

    NASA Astrophysics Data System (ADS)

    Hendrix, Roy E.; Dugger, Paul H.

    1983-03-01

    Since the onset of user testing in the AEDC aeroballistic ranges in 1961, concentrated efforts in such areas as model launching techniques, test environment simulation, and specialized instrumentation have been made to enhance the usefulness of these test facilities. A wide selection of specialized instrumentation has been developed over the years to provide, among other features, panoramic photographic coverage of test models during flight. Pulsed ruby lasers, xenon flash lamps, visible-light spark sources, and flash X-ray systems are employed as short-duration radiation sources in various front-light and back-light photographic systems. Visible-light and near infrared image intensifier diodes are used to achieve high-speed shuttering in photographic pyrometry systems that measure surface temperatures of test models in flight. Turbine-driven framing cameras are used to provide multiframe photography of such high-speed phenomena as impact debris formation and model encounter with erosive fields. As a result, the capabilities of these ballistic range test units have increased significantly in regard to the types of tests that can be accommodated and to the quality and quantity of data that can be provided. Presently, five major range and companion track facilities are active in conducting hypervelocity testing in AEDC's von K6rman Gas Dynamics Facility (VKF): Ranges G, K, and S-1 and Tracks G and K. The following types of tests are conducted in these test units: ablation/erosion, transpiration-cooled nosetip (TCNT), nosetip transition, heat transfer, aerodynamic, cannon projectile, rocket contrail, reentry physics, and hypervelocity impact. The parallel achievements in high-speed photography and testing capabilities are discussed, and the significant role of photographic systems in the development of the overall testing capabilities of the AEDC range and track facilities is illustrated in numerous examples of photographic results.

  2. Evaluation of intermodal passenger transfer facilities

    DOT National Transportation Integrated Search

    1994-09-01

    The Wisconsin Department of Transportation has initiated a study into the feasibility of locating an intermodal passenger transportation facility in downtown Milwaukee. That feasibilty study requires an evaluation of a very wide range of alternatives...

  3. Subscale Flight Testing for Aircraft Loss of Control: Accomplishments and Future Directions

    NASA Technical Reports Server (NTRS)

    Cox, David E.; Cunningham, Kevin; Jordan, Thomas L.

    2012-01-01

    Subscale flight-testing provides a means to validate both dynamic models and mitigation technologies in the high-risk flight conditions associated with aircraft loss of control. The Airborne Subscale Transport Aircraft Research (AirSTAR) facility was designed to be a flexible and efficient research facility to address this type of flight-testing. Over the last several years (2009-2011) it has been used to perform 58 research flights with an unmanned, remotely-piloted, dynamically-scaled airplane. This paper will present an overview of the facility and its architecture and summarize the experimental data collected. All flights to date have been conducted within visual range of a safety observer. Current plans for the facility include expanding the test volume to altitudes and distances well beyond visual range. The architecture and instrumentation changes associated with this upgrade will also be presented.

  4. Preliminary design study for an atomospheric science facility

    NASA Technical Reports Server (NTRS)

    Hutchison, R.

    1972-01-01

    The activities and results of the Atmospheric Science Facility preliminary design study are reported. The objectives of the study were to define the scientific goals, to determine the range of experiment types, and to develop the preliminary instrument design requirements for a reusable, general purpose, optical research facility for investigating the earth's atmosphere from a space shuttle orbital vehicle.

  5. 33 CFR 154.814 - Facility requirements for vessel vapor overpressure and vacuum protection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... vapor at a rate of not less than 1.25 times the facility's maximum liquid transfer rate for cargo for... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION FACILITIES TRANSFERRING OIL OR HAZARDOUS... in the vessel's cargo tanks within this range at any cargo transfer rate less than or equal to the...

  6. Standards for material handling and facilities equipment proofload testing

    NASA Technical Reports Server (NTRS)

    Bonn, S. P.

    1970-01-01

    Document provides information on verifying the safety of material handling and facilities equipment /MH/FE/, ranging from monorail systems to ladders and non-powered mobile equipment. Seven catagories of MH/FE equipment are defined.

  7. Geohydrologic conditions at the nuclear-fuels reprocessing plant and waste-management facilities at the Western New York Nuclear Service Center, Cattaraugus County, New York

    USGS Publications Warehouse

    Bergeron, M.P.; Kappel, W.M.; Yager, R.M.

    1987-01-01

    A nuclear-fuel reprocessing plant, a high-level radioactive liquid-waste tank complex, and related waste facilities occupy 100 hectares (ha) within the Western New York Nuclear Service Center near West Valley, N.Y. The facilities are underlain by glacial and postglacial deposits that fill an ancestrial bedrock valley. The main plant facilities are on an elevated plateau referred to as the north plateau. Groundwater on the north plateau moves laterally within a surficial sand and gravel from the main plant building to areas northeast, east, and southeast of the facilities. The sand and gravel ranges from 1 to 10 m thick and has a hydraulic conductivity ranging from 0.1 to 7.9 m/day. Two separate burial grounds, a 4-ha area for low-level radioactive waste disposal and a 2.9-ha area for disposal of higher-level waste are excavated into a clay-rich till that ranges from 22 to 28 m thick. Migration of an organic solvent from the area of higher level waste at shallow depth in the till suggests that a shallow, fractured, oxidized, and weathered till is a significant pathway for lateral movement of groundwater. Below this zone, groundwater moves vertically downward through the till to recharge a lacustrine silt and fine sand. Within the saturated parts of the lacustrine unit, groundwater moves laterally to the northeast toward Buttermilk Creek. Hydraulic conductivity of the till, based on field and laboratory analyses , ranges from 0.000018 to 0.000086 m/day. (USGS)

  8. Calibration of the NASA Glenn 8- by 6-Foot Supersonic Wind Tunnel (1996 and 1997 Tests)

    NASA Technical Reports Server (NTRS)

    Arrington, E. Allen

    2012-01-01

    There were several physical and operational changes made to the NASA Glenn Research Center 8- by 6-Foot Supersonic Wind Tunnel during the period of 1992 through 1996. Following each of these changes, a facility calibration was conducted to provide the required information to support the research test programs. Due to several factors (facility research test schedule, facility downtime and continued facility upgrades), a full test section calibration was not conducted until 1996. This calibration test incorporated all test section configurations and covered the existing operating range of the facility. However, near the end of that test entry, two of the vortex generators mounted on the compressor exit tailcone failed causing minor damage to the honeycomb flow straightener. The vortex generators were removed from the facility and calibration testing was terminated. A follow-up test entry was conducted in 1997 in order to fully calibrate the facility without the effects of the vortex generators and to provide a complete calibration of the newly expanded low speed operating range. During the 1997 tunnel entry, all planned test points required for a complete test section calibration were obtained. This data set included detailed in-plane and axial flow field distributions for use in quantifying the test section flow quality.

  9. Odontocete Studies Off the Pacific Missile Range Facility in February 2013: Satellite-Tagging, Photo-Identification, and Passive Acoustic Monitoring for Species Verification

    DTIC Science & Technology

    2013-12-16

    ODONTOCETE STUDIES OFF THE PACIFIC MISSILE RANGE FACILITY IN FEBRUARY 2013: SATELLITE-TAGGING, PHOTO- IDENTIFICATION, AND PASSIVE ACOUSTIC...burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching...existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this

  10. Long-Range Facilities - Plan

    DTIC Science & Technology

    1981-07-31

    3. DATES COVERED 00-00-1981 to 00-00-1981 4. TITLE AND SUBTITLE Long-Range Facilities - Plan 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM...sternwheeler “Mark Twain” for Disneyland and fabrication of eight 52 foot submarines for the Disneyland “Navy.” This was followed by fabrication of the masts...converting the PRESIDENT GRANT , PRESIDENT McKINLEY and PRESIDENT FILLMORE to container ships for American President Lines, Ltd. These ships were designed to

  11. Space Technology Demonstrations Using Low Cost, Short-Schedule Airborne and Range Facilities at the Dryden Flight Research Center

    NASA Technical Reports Server (NTRS)

    Carter, John; Kelly, John; Jones, Dan; Lee, James

    2013-01-01

    There is a national effort to expedite advanced space technologies on new space systems for both government and commercial applications. In order to lower risk, these technologies should be demonstrated in a relevant environment before being installed in new space systems. This presentation introduces several low cost, short schedule space technology demonstrations using airborne and range facilities available at the Dryden Flight Research Center.

  12. Status of the national transonic facility

    NASA Technical Reports Server (NTRS)

    Mckinney, L. W.; Gloss, B. B.

    1982-01-01

    The National Transonic Facility at NASA Langley Research Center, scheduled for completion in July, 1982, is described with emphasis on model and instrumentation activities, calibration plans and some initial research plans. Performance capabilities include a Mach number range of 0.2-1.2, a pressure range of 1-9 atmospheres, and a temperature range of 77-350 K, which will produce a maximum Reynolds number of 120 million at a Mach number of 1.0, based on a 0.25 m chord. A comprehensive tunnel calibration program is planned, which will cover basic tunnel calibration, data qualities, and data comparisons with other facilites and flights.

  13. Stockouts of HIV commodities in public health facilities in Kinshasa: Barriers to end HIV

    PubMed Central

    Bossard, Claire; Verdonck, Kristien; Owiti, Philip; Casteels, Ilse; Mashako, Maria; Van Cutsem, Gilles; Ellman, Tom

    2018-01-01

    Stockouts of HIV commodities increase the risk of treatment interruption, antiretroviral resistance, treatment failure, morbidity and mortality. The study objective was to assess the magnitude and duration of stockouts of HIV medicines and diagnostic tests in public facilities in Kinshasa, Democratic Republic of the Congo. This was a cross-sectional survey involving visits to facilities and warehouses in April and May 2015. All zonal warehouses, all public facilities with more than 200 patients on antiretroviral treatment (ART) (high-burden facilities) and a purposive sample of facilities with 200 or fewer patients (low-burden facilities) in Kinshasa were selected. We focused on three adult ART formulations, cotrimoxazole tablets, and HIV diagnostic tests. Availability of items was determined by physical check, while stockout duration until the day of the survey visit was verified with stock cards. In case of ART stockouts, we asked the pharmacist in charge what the facility coping strategy was for patients needing those medicines. The study included 28 high-burden facilities and 64 low-burden facilities, together serving around 22000 ART patients. During the study period, a national shortage of the newly introduced first-line regimen Tenofovir-Lamivudine-Efavirenz resulted in stockouts of this regimen in 56% of high-burden and 43% of low-burden facilities, lasting a median of 36 (interquartile range 29–90) and 44 days (interquartile range 24–90) until the day of the survey visit, respectively. Each of the other investigated commodities were found out of stock in at least two low-burden and two high-burden facilities. In 30/41 (73%) of stockout cases, the commodity was absent at the facility but present at the upstream warehouse. In 30/57 (54%) of ART stockout cases, patients did not receive any medicines. In some cases, patients were switched to different ART formulations or regimens. Stockouts of HIV commodities were common in the visited facilities. Introduction of new ART regimens needs additional planning. PMID:29351338

  14. Stockouts of HIV commodities in public health facilities in Kinshasa: Barriers to end HIV.

    PubMed

    Gils, Tinne; Bossard, Claire; Verdonck, Kristien; Owiti, Philip; Casteels, Ilse; Mashako, Maria; Van Cutsem, Gilles; Ellman, Tom

    2018-01-01

    Stockouts of HIV commodities increase the risk of treatment interruption, antiretroviral resistance, treatment failure, morbidity and mortality. The study objective was to assess the magnitude and duration of stockouts of HIV medicines and diagnostic tests in public facilities in Kinshasa, Democratic Republic of the Congo. This was a cross-sectional survey involving visits to facilities and warehouses in April and May 2015. All zonal warehouses, all public facilities with more than 200 patients on antiretroviral treatment (ART) (high-burden facilities) and a purposive sample of facilities with 200 or fewer patients (low-burden facilities) in Kinshasa were selected. We focused on three adult ART formulations, cotrimoxazole tablets, and HIV diagnostic tests. Availability of items was determined by physical check, while stockout duration until the day of the survey visit was verified with stock cards. In case of ART stockouts, we asked the pharmacist in charge what the facility coping strategy was for patients needing those medicines. The study included 28 high-burden facilities and 64 low-burden facilities, together serving around 22000 ART patients. During the study period, a national shortage of the newly introduced first-line regimen Tenofovir-Lamivudine-Efavirenz resulted in stockouts of this regimen in 56% of high-burden and 43% of low-burden facilities, lasting a median of 36 (interquartile range 29-90) and 44 days (interquartile range 24-90) until the day of the survey visit, respectively. Each of the other investigated commodities were found out of stock in at least two low-burden and two high-burden facilities. In 30/41 (73%) of stockout cases, the commodity was absent at the facility but present at the upstream warehouse. In 30/57 (54%) of ART stockout cases, patients did not receive any medicines. In some cases, patients were switched to different ART formulations or regimens. Stockouts of HIV commodities were common in the visited facilities. Introduction of new ART regimens needs additional planning.

  15. BNL accelerator-based radiobiology facilities

    NASA Technical Reports Server (NTRS)

    Lowenstein, D. I.

    2001-01-01

    For the past several years, the Alternating Gradient Synchrotron (AGS) at Brookhaven National Laboratory (USA) has provided ions of iron, silicon and gold, at energies from 600 MeV/nucleon to 10 GeV/nucleon, for the US National Aeronautics and Space Administration (NASA) radiobiology research program. NASA has recently funded the construction of a new dedicated ion facility, the Booster Applications Facility (BAF). The Booster synchrotron will supply ion beams ranging from protons to gold, in an energy range from 40-3000 MeV/nucleon with maximum beam intensities of 10(10) to 10(11) ions per pulse. The BAF Project will be described and the future AGS and BAF operation plans will be presented.

  16. BNL accelerator-based radiobiology facilities.

    PubMed

    Lowenstein, D I

    2001-01-01

    For the past several years, the Alternating Gradient Synchrotron (AGS) at Brookhaven National Laboratory (USA) has provided ions of iron, silicon and gold, at energies from 600 MeV/nucleon to 10 GeV/nucleon, for the US National Aeronautics and Space Administration (NASA) radiobiology research program. NASA has recently funded the construction of a new dedicated ion facility, the Booster Applications Facility (BAF). The Booster synchrotron will supply ion beams ranging from protons to gold, in an energy range from 40-3000 MeV/nucleon with maximum beam intensities of 10(10) to 10(11) ions per pulse. The BAF Project will be described and the future AGS and BAF operation plans will be presented.

  17. High-Flux Solar Furnace Facility | Concentrating Solar Power | NREL

    Science.gov Websites

    High-Flux Solar Furnace Facility High-Flux Solar Furnace Facility NREL's High-Flux Solar Furnace (HFSF) is a 10-kW optical furnace for testing high-temperature processes or applications requiring high range of technologies with a diverse set of experimental requirements. The high heating rates create the

  18. Final Environmental Planning Technical Report. Land Use

    DTIC Science & Technology

    1984-01-01

    COLLEGE RECREATIONAL FACILITIES Recreational Facilities Number Indoor Facilities Gym (Basketball, Volleyball) 1 Weight Room 1 Handball /Racquetball...Clubs/Gymnasiums 4 YMCA Gloria Stevens Figure Salon Nautilus Fitness Center Rocky Mountain Health Club 10 handball /racquetball courts, swimming pool, gym...Range I Roller Rink 1 Indoor Handball /Racquetball Courts 5 Indoor Softball Diamonds 3 Lighted Picnic Tables 14 Youth Baseball Diamonds 5 Tennis Courts

  19. Capital Program, School District of Philadelphia: July 1, 1968 to June 30, 1974.

    ERIC Educational Resources Information Center

    Philadelphia Board of Education, PA.

    This report presents the School District of Philadelphia's long-range plan for school facilities and, based upon it, a capital program for the years 1969 through 1974. The plan for school facilities is preceded by a summary of present facility conditions and a consideration of indicated needs for expansion. General fiscal policies, a total program…

  20. Skylab 2 facilities and environmental measurements program

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A list of the facilities and environmental measurements to be monitored in support of the Skylab 2 vehicle is presented. The data include measurement identification number, description, transducer operating range, recorder type, and drawings illustrating measurement location.

  1. 69. Photograph of line drawing. ISOMETRIC VIEW OF 500,000 POUND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    69. Photograph of line drawing. ISOMETRIC VIEW OF 500,000 POUND STATIC TEST FACILITY, NO DATE - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  2. 70. Photograph of line drawing. TOPOGRAPHIC SITE PLAN OF 500,000 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    70. Photograph of line drawing. TOPOGRAPHIC SITE PLAN OF 500,000 POUND STATIC TEST FACILITY, APRIL 1947 - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  3. 72. Photograph of line drawing. SOUTH ELEVATION OF MOTOR CARRIAGE, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    72. Photograph of line drawing. SOUTH ELEVATION OF MOTOR CARRIAGE, 500,000 POUND STATIC TEST FACILITY, NO DATE - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  4. Does proximity of women to facilities with better choice of contraceptives affect their contraceptive utilization in rural Ethiopia?

    PubMed Central

    Spigt, Mark; Seme, Assefa; Amogne, Ayanaw; Skrøvseth, Stein; Desta, Selamawit; Radloff, Scott; GeertJan, Dinant

    2017-01-01

    Background There is limited evidence of the linkage between contraceptive use, the range of methods available and level of contraceptive stocks at health facilities and distance to facility in developing countries. The present analysis aims at examining the influence of contraceptive method availability and distance to the nearby facilities on modern contraceptive utilization among married women in rural areas in Ethiopia using geo-referenced data. Methods We used data from the first round of surveys of the Performance Monitoring & Accountability 2020 project in Ethiopia (PMA2020/Ethiopia-2014). The survey was conducted in a sample of 200 enumeration areas (EAs) where for each EA, 35 households and up to 3 public or private health service delivery points (SDPs) were selected. The main outcome variable was individual use of a contraceptive method for married women in rural Ethiopia. Correlates of interest include distance to nearby health facilities, range of contraceptives available in facilities, household wealth index, and the woman’s educational status, age, and parity and whether she recently visited a health facility. This analysis primarily focuses on stock provision at public SDPs. Results Overall complete information was collected from 1763 married rural women ages 15–49 years and 198 SDPs in rural areas (97.1% public). Most rural women (93.9%) live within 5 kilometers of their nearest health post while a much lower proportion (52.2%) live within the same distance to the nearest health centers and hospital (0.8%), respectively. The main sources of modern contraceptive methods for married rural women were health posts (48.8%) and health centers (39.0%). The mean number of the types of contraceptive methods offered by hospitals, health centers and health posts was 6.2, 5.4 and 3.7 respectively. Modern contraceptive use (mCPR) among rural married women was 27.3% (95% CI: 25.3, 29.5). The percentage of rural married women who use modern contraceptives decreased as distance from the nearest SDP increased; 41.2%, 27.5%, 22.0%, and 22.6% of women living less than 2 kilometers, 2 to 3.9kilometers, 4 to 5.9 kilometers and 6 or more kilometers, respectively (p-value<0.01). Additionally, women who live close to facilities that offer a wider range of contraceptive methods were significantly more likely to use modern contraceptives. The mCPR ranged from 42.3% among women who live within 2 kilometers of facilities offering 3 or more methods to 22.5% among women living more than 6 kilometers away from the nearest facility with the same number (3 or more methods) available after adjusting for observed covariates. Conclusions Although the majority of the Ethiopian population lives within a relatively close distance to lower level facilities (health posts), the number and range of methods available (method choice) and proximity are independently associated with contraceptive utilization. By demonstrating the extent to which objective measures of distance (of relatively small magnitude) explain variation in contraceptive use among rural women, the study fills an important planning gap for family planning programs operating in resource limited settings. PMID:29131860

  5. Does proximity of women to facilities with better choice of contraceptives affect their contraceptive utilization in rural Ethiopia?

    PubMed

    Shiferaw, Solomon; Spigt, Mark; Seme, Assefa; Amogne, Ayanaw; Skrøvseth, Stein; Desta, Selamawit; Radloff, Scott; Tsui, Amy; GeertJan, Dinant

    2017-01-01

    There is limited evidence of the linkage between contraceptive use, the range of methods available and level of contraceptive stocks at health facilities and distance to facility in developing countries. The present analysis aims at examining the influence of contraceptive method availability and distance to the nearby facilities on modern contraceptive utilization among married women in rural areas in Ethiopia using geo-referenced data. We used data from the first round of surveys of the Performance Monitoring & Accountability 2020 project in Ethiopia (PMA2020/Ethiopia-2014). The survey was conducted in a sample of 200 enumeration areas (EAs) where for each EA, 35 households and up to 3 public or private health service delivery points (SDPs) were selected. The main outcome variable was individual use of a contraceptive method for married women in rural Ethiopia. Correlates of interest include distance to nearby health facilities, range of contraceptives available in facilities, household wealth index, and the woman's educational status, age, and parity and whether she recently visited a health facility. This analysis primarily focuses on stock provision at public SDPs. Overall complete information was collected from 1763 married rural women ages 15-49 years and 198 SDPs in rural areas (97.1% public). Most rural women (93.9%) live within 5 kilometers of their nearest health post while a much lower proportion (52.2%) live within the same distance to the nearest health centers and hospital (0.8%), respectively. The main sources of modern contraceptive methods for married rural women were health posts (48.8%) and health centers (39.0%). The mean number of the types of contraceptive methods offered by hospitals, health centers and health posts was 6.2, 5.4 and 3.7 respectively. Modern contraceptive use (mCPR) among rural married women was 27.3% (95% CI: 25.3, 29.5). The percentage of rural married women who use modern contraceptives decreased as distance from the nearest SDP increased; 41.2%, 27.5%, 22.0%, and 22.6% of women living less than 2 kilometers, 2 to 3.9kilometers, 4 to 5.9 kilometers and 6 or more kilometers, respectively (p-value<0.01). Additionally, women who live close to facilities that offer a wider range of contraceptive methods were significantly more likely to use modern contraceptives. The mCPR ranged from 42.3% among women who live within 2 kilometers of facilities offering 3 or more methods to 22.5% among women living more than 6 kilometers away from the nearest facility with the same number (3 or more methods) available after adjusting for observed covariates. Although the majority of the Ethiopian population lives within a relatively close distance to lower level facilities (health posts), the number and range of methods available (method choice) and proximity are independently associated with contraceptive utilization. By demonstrating the extent to which objective measures of distance (of relatively small magnitude) explain variation in contraceptive use among rural women, the study fills an important planning gap for family planning programs operating in resource limited settings.

  6. Facility-Level Variation in Hospitalization, Mortality, and Costs in the 30 Days After Percutaneous Coronary Intervention: Insights on Short-Term Healthcare Value From the Veterans Affairs Clinical Assessment, Reporting, and Tracking System (VA CART) Program.

    PubMed

    Bradley, Steven M; O'Donnell, Colin I; Grunwald, Gary K; Liu, Chuan-Fen; Hebert, Paul L; Maddox, Thomas M; Jesse, Robert L; Fihn, Stephan D; Rumsfeld, John S; Ho, P Michael

    2015-07-14

    Policies to reduce unnecessary hospitalizations after percutaneous coronary intervention (PCI) are intended to improve healthcare value by reducing costs while maintaining patient outcomes. Whether facility-level hospitalization rates after PCI are associated with cost of care is unknown. We studied 32,080 patients who received PCI at any 1 of 62 Veterans Affairs hospitals from 2008 to 2011. We identified facility outliers for 30-day risk-standardized hospitalization, mortality, and cost. Compared with the risk-standardized average, 2 hospitals (3.2%) had a lower-than-expected hospitalization rate, and 2 hospitals (3.2%) had a higher-than-expected hospitalization rate. We observed no statistically significant variation in facility-level risk-standardized mortality. The facility-level unadjusted median per patient 30-day total cost was $23,820 (interquartile range, $19,604-$29,958). Compared with the risk-standardized average, 17 hospitals (27.4%) had lower-than-expected costs, and 14 hospitals (22.6%) had higher-than-expected costs. At the facility level, the index PCI accounted for 83.1% of the total cost (range, 60.3%-92.2%), whereas hospitalization after PCI accounted for only 5.8% (range, 2.0%-12.7%) of the 30-day total cost. Facilities with higher hospitalization rates were not more expensive (Spearman ρ=0.16; 95% confidence interval, -0.09 to 0.39; P=0.21). In this national study, hospitalizations in the 30 day after PCI accounted for only 5.8% of 30-day cost, and facility-level cost was not correlated with hospitalization rates. This challenges the focus on reducing hospitalizations after PCI as an effective means of improving healthcare value. Opportunities remain to improve PCI value by reducing the variation in total cost of PCI without compromising patient outcomes. © 2015 American Heart Association, Inc.

  7. Photovoltaic Systems Test Facilities: Existing capabilities compilation

    NASA Technical Reports Server (NTRS)

    Volkmer, K.

    1982-01-01

    A general description of photovoltaic systems test facilities (PV-STFs) operated under the U.S. Department of Energy's photovoltaics program is given. Descriptions of a number of privately operated facilities having test capabilities appropriate to photovoltaic hardware development are given. A summary of specific, representative test capabilities at the system and subsystem level is presented for each listed facility. The range of system and subsystem test capabilities available to serve the needs of both the photovoltaics program and the private sector photovoltaics industry is given.

  8. Geodetic Imaging Lidar: Applications for high-accuracy, large area mapping with NASA's upcoming high-altitude waveform-based airborne laser altimetry Facility

    NASA Astrophysics Data System (ADS)

    Blair, J. B.; Rabine, D.; Hofton, M. A.; Citrin, E.; Luthcke, S. B.; Misakonis, A.; Wake, S.

    2015-12-01

    Full waveform laser altimetry has demonstrated its ability to capture highly-accurate surface topography and vertical structure (e.g. vegetation height and structure) even in the most challenging conditions. NASA's high-altitude airborne laser altimeter, LVIS (the Land Vegetation, and Ice Sensor) has produced high-accuracy surface maps over a wide variety of science targets for the last 2 decades. Recently NASA has funded the transition of LVIS into a full-time NASA airborne Facility instrument to increase the amount and quality of the data and to decrease the end-user costs, to expand the utilization and application of this unique sensor capability. Based heavily on the existing LVIS sensor design, the Facility LVIS instrument includes numerous improvements for reliability, resolution, real-time performance monitoring and science products, decreased operational costs, and improved data turnaround time and consistency. The development of this Facility instrument is proceeding well and it is scheduled to begin operations testing in mid-2016. A comprehensive description of the LVIS Facility capability will be presented along with several mission scenarios and science applications examples. The sensor improvements included increased spatial resolution (footprints as small as 5 m), increased range precision (sub-cm single shot range precision), expanded dynamic range, improved detector sensitivity, operational autonomy, real-time flight line tracking, and overall increased reliability and sensor calibration stability. The science customer mission planning and data product interface will be discussed. Science applications of the LVIS Facility include: cryosphere, territorial ecology carbon cycle, hydrology, solid earth and natural hazards, and biodiversity.

  9. General service and child immunization-specific readiness assessment of healthcare facilities in two selected divisions in Bangladesh.

    PubMed

    Shawon, Md Shajedur Rahman; Adhikary, Gourab; Ali, Md Wazed; Shamsuzzaman, Md; Ahmed, Shahabuddin; Alam, Nurul; Shackelford, Katya A; Woldeab, Alexander; Lim, Stephen S; Levine, Aubrey; Gakidou, Emmanuela; Uddin, Md Jasim

    2018-01-25

    Service readiness of health facilities is an integral part of providing comprehensive quality healthcare to the community. Comprehensive assessment of general and service-specific (i.e. child immunization) readiness will help to identify the bottlenecks in healthcare service delivery and gaps in equitable service provision. Assessing healthcare facilities readiness also helps in optimal policymaking and resource allocation. A health facility survey was conducted between March 2015 and December 2015 in two purposively selected divisions in Bangladesh; i.e. Rajshahi division (high performing) and Sylhet division (low performing). A total of 123 health facilities were randomly selected from different levels of service, both public and private, with variation in sizes and patient loads from the list of facilities. Data on various aspects of healthcare facility were collected by interviewing key personnel. General service and child immunization specific service readiness were assessed using the Service Availability and Readiness Assessment (SARA) manual developed by World Health Organization (WHO). The analyses were stratified by division and level of healthcare facilities. The general service readiness index for pharmacies, community clinics, primary care facilities and higher care facilities were 40.6%, 60.5%, 59.8% and 69.5%, respectively in Rajshahi division and 44.3%, 57.8%, 57.5% and 73.4%, respectively in Sylhet division. Facilities at all levels had the highest scores for basic equipment (ranged between 51.7% and 93.7%) and the lowest scores for diagnostic capacity (ranged between 0.0% and 53.7%). Though facilities with vaccine storage capacity had very high levels of service readiness for child immunization, facilities without vaccine storage capacity lacked availability of many tracer items. Regarding readiness for newly introduced pneumococcal conjugate vaccine (PCV) and inactivated polio vaccine (IPV), most of the surveyed facilities reported lack of sufficient funding and resources (antigen) for training programs. Our study suggested that health facilities suffered from lack of readiness in various aspects, most notably in diagnostic capacity. Conversely, with very few challenges, nearly all the health facilities designated to provide immunization services were ready to deliver routine childhood immunization services as well as newly introduced PCV and IPV.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jager, Yetta; Forsythe, Patrick S.; McLaughlin, Robert L.

    The majority of large North American rivers are fragmented by dams that interrupt migrations of wide-ranging fishes like sturgeons. Reconnecting habitat is viewed as an important means of protecting sturgeon species in U.S. rivers because these species have lost between 5% and 60% of their historical ranges. Unfortunately, facilities designed to pass other fishes have rarely worked well for sturgeons. The most successful passage facilities were sized appropriately for sturgeons and accommodated bottom-oriented species. For upstream passage, facilities with large entrances, full-depth guidance systems, large lifts, or wide fishways without obstructions or tight turns worked well. However, facilitating upstream migrationmore » is only half the battle. Broader recovery for linked sturgeon populations requires safe round-trip passage involving multiple dams. The most successful downstream passage facilities included nature-like fishways, large canal bypasses, and bottom-draw sluice gates. We outline an adaptive approach to implementing passage that begins with temporary programs and structures and monitors success both at the scale of individual fish at individual dams and the scale of metapopulations in a river basin. The challenge will be to learn from past efforts and reconnect North American sturgeon populations in a way that promotes range expansion and facilitates population recovery.« less

  11. Reconnecting fragmented sturgeon populations in North American rivers

    USGS Publications Warehouse

    Jager, Henriette; Parsley, Michael J.; Cech, Joseph J. Jr.; McLaughlin, R.L.; Forsythe, Patrick S.; Elliott, Robert S.

    2016-01-01

    The majority of large North American rivers are fragmented by dams that interrupt migrations of wide-ranging fishes like sturgeons. Reconnecting habitat is viewed as an important means of protecting sturgeon species in U.S. rivers because these species have lost between 5% and 60% of their historical ranges. Unfortunately, facilities designed to pass other fishes have rarely worked well for sturgeons. The most successful passage facilities were sized appropriately for sturgeons and accommodated bottom-oriented species. For upstream passage, facilities with large entrances, full-depth guidance systems, large lifts, or wide fishways without obstructions or tight turns worked well. However, facilitating upstream migration is only half the battle. Broader recovery for linked sturgeon populations requires safe “round-trip” passage involving multiple dams. The most successful downstream passage facilities included nature-like fishways, large canal bypasses, and bottom-draw sluice gates. We outline an adaptive approach to implementing passage that begins with temporary programs and structures and monitors success both at the scale of individual fish at individual dams and the scale of metapopulations in a river basin. The challenge will be to learn from past efforts and reconnect North American sturgeon populations in a way that promotes range expansion and facilitates population recovery.

  12. The design of a long-range megatransport aircraft

    NASA Technical Reports Server (NTRS)

    Weisshaar, Terrence A.; Allen, Carl L.

    1992-01-01

    Aircraft manufacturers are examining the market and feasibility of long-range passenger aircraft carrying more than 600 passengers. These aircraft would carry travelers at reduced cost and, at the same time, reduce congestion around major airports. The design of a large, long-range transport involves broad issues such as: the integration of airport terminal facilities; passenger loading and unloading; trade-offs between aircraft size and the cost to reconfigure these existing facilities; and, defeating the 'square-cube' law. Thirteen Purdue design teams generated RFP's that defined passenger capability and range, based upon team perception of market needs and infrastructure constraints. Turbofan engines were designed by each group to power these aircraft. The design problem and the variety of solutions developed are reviewed.

  13. Temporal Variability of Upper-level Winds at the Eastern Range, Western Range and Wallops Flight Facility

    NASA Technical Reports Server (NTRS)

    Decker, Ryan K.; Barbre, Robert E., Jr.

    2014-01-01

    Space launch vehicles incorporate upper-level wind profiles to determine wind effects on the vehicle and for a commit to launch decision. These assessments incorporate wind profiles measured hours prior to launch and may not represent the actual wind the vehicle will fly through. Uncertainty in the upper-level winds over the time period between the assessment and launch can be mitigated by a statistical analysis of wind change over time periods of interest using historical data from the launch range. Five sets of temporal wind pairs at various times (.75, 1.5, 2, 3 and 4-hrs) at the Eastern Range, Western Range and Wallops Flight Facility were developed for use in upper-level wind assessments. Database development procedures as well as statistical analysis of temporal wind variability at each launch range will be presented.

  14. Current algebra formulation of radiative corrections in gauge theories and the universality of the weak interactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sirlin, A.

    1978-07-01

    A current algebra formulation of the radiative corrections in gauge theories, with special applications to the analysis of the universality of the weak interactions, is developed in the framework of quantum chromodynamics. For definiteness, we work in the SU(2) x U(1) model with four quark flavors, but the methods are quite general and can be applied to other theories. The explicit cancellation of ultraviolet divergences for arbitrary semileptonic processes is achieved relying solely on the Ward identities and general considerations, both in the W and Higgs sectors. The finite parts of order G/sub F/..cap alpha.. are then evaluated in themore » case of the superallowed Fermi transitions, including small effects proportional to g/sup -2//sub S/(kappa/sup 2/), which are induced by the strong interactions in the asymptotic domain. We consider here both the simplest version of the Weinberg--Salam model in which the Higgs scalars transform as a single isospinsor, as well as the case of general symmetry breaking. Except for the small effects proportional to g/sup -2//sub S/(kappa/sup 2/), the results are identical to the answers previously found on the basis of heuristic arguments. The phenomenological verification of Cabibbo universality on the basis of these corrections and the superallowed Fermi transitions has been discussed before and found to be in very good agreement with present experimental evidence. The analogous calculation for the transition rate of pion ..beta.. decay is given. Theoretical alternatives to quantum chromdynamics as a framework for the evaluate ion of the radiative corrections are briefly discussed. The appendixes contain a generalization of an important result in the theory of radiative corrections, an analysis of the hadronic contributions to the W and phi propagators, mathematical methods for evaluating the g/sup -2//sub S/(kappa/sup 2/) corrections, and discussions of quark mass renormalization and the absence of operator ''seagulls'' in the hadronic correlation functions.« less

  15. Variation in infection prevention practices in dialysis facilities: results from the national opportunity to improve infection control in ESRD (End-Stage Renal Disease) project.

    PubMed

    Chenoweth, Carol E; Hines, Stephen C; Hall, Kendall K; Saran, Rajiv; Kalbfleisch, John D; Spencer, Teri; Frank, Kelly M; Carlson, Diane; Deane, Jan; Roys, Erik; Scholz, Natalie; Parrotte, Casey; Messana, Joseph M

    2015-07-01

    OBJECTIVE To observe patient care across hemodialysis facilities enrolled in the National Opportunity to Improve Infection Control in ESRD (end-stage renal disease) (NOTICE) project in order to evaluate adherence to evidence-based practices aimed at prevention of infection. SETTING AND PARTICIPANTS Thirty-four hemodialysis facilities were randomly selected from among 772 facilities in 4 end-stage renal disease participating networks. Facility selection was stratified on dialysis organization affiliation, size, socioeconomic status, and urban/rural status. MEASUREMENTS Trained infection control evaluators used an infection control worksheet to observe 73 distinct infection control practices at the hemodialysis facilities, from October 1, 2011, through January 31, 2012. RESULTS There was considerable variation in infection control practices across enrolled facilities. Overall adherence to recommended practices was 68% (range, 45%-92%) across all facilities. Overall adherence to expected hand hygiene practice was 72% (range, 10%-100%). Compliance to hand hygiene before and after procedures was high; however, during procedures hand hygiene compliance averaged 58%. Use of chlorhexidine as the specific agent for exit site care was 19% overall but varied from 0% to 35% by facility type. The 8 checklists varied in the frequency of perfect performance from 0% for meeting every item on the checklist for disinfection practices to 22% on the arteriovenous access practices at initiation. CONCLUSIONS Our findings suggest that there are many areas for improvement in hand hygiene and other infection prevention practices in end-stage renal disease. These NOTICE project findings will help inform the development of a larger quality improvement initiative at dialysis facilities.

  16. Anaerobic digestion and digestate use: accounting of greenhouse gases and global warming contribution.

    PubMed

    Møller, Jacob; Boldrin, Alessio; Christensen, Thomas H

    2009-11-01

    Anaerobic digestion (AD) of source-separated municipal solid waste (MSW) and use of the digestate is presented from a global warming (GW) point of view by providing ranges of greenhouse gas (GHG) emissions that are useful for calculation of global warming factors (GWFs), i.e. the contribution to GW measured in CO(2)-equivalents per tonne of wet waste. The GHG accounting was done by distinguishing between direct contributions at the AD facility and indirect upstream or downstream contributions. GHG accounting for a generic AD facility with either biogas utilization at the facility or upgrading of the gas for vehicle fuel resulted in a GWF from -375 (a saving) to 111 (a load) kg CO(2)-eq. tonne(-1) wet waste. In both cases the digestate was used for fertilizer substitution. This large range was a result of the variation found for a number of key parameters: energy substitution by biogas, N(2)O-emission from digestate in soil, fugitive emission of CH( 4), unburned CH(4), carbon bound in soil and fertilizer substitution. GWF for a specific type of AD facility was in the range -95 to -4 kg CO(2)-eq. tonne(-1) wet waste. The ranges of uncertainty, especially of fugitive losses of CH(4) and carbon sequestration highly influenced the result. In comparison with the few published GWFs for AD, the range of our data was much larger demonstrating the need to use a consistent and robust approach to GHG accounting and simultaneously accept that some key parameters are highly uncertain.

  17. Activation of the E1 Ultra High Pressure Propulsion Test Facility at Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Messer, Bradley; Messer, Elisabeth; Sewell, Dale; Sass, Jared; Lott, Jeff; Dutreix, Lionel, III

    2001-01-01

    After a decade of construction and a year of activation the El Ultra High Pressure Propulsion Test Facility at NASA's Stennis Space Center is fully operational. The El UHP Propulsion Test Facility is a multi-cell, multi-purpose component and engine test facility . The facility is capable of delivering cryogenic propellants at low, high, and ultra high pressures with flow rates ranging from a few pounds per second up to two thousand pounds per second. Facility activation is defined as a series of tasks required to transition between completion of construction and facility operational readiness. Activating the El UHP Propulsion Test Facility involved independent system checkouts, propellant system leak checks, fluid and gas sampling, gaseous system blow downs, pressurization and vent system checkouts, valve stability testing, valve tuning cryogenic cold flows, and functional readiness tests.

  18. Marshall Space Flight Center's Impact Testing Facility Capabilities

    NASA Technical Reports Server (NTRS)

    Finchum, Andy; Hubbs, Whitney; Evans, Steve

    2008-01-01

    Marshall Space Flight Center s (MSFC) Impact Testing Facility (ITF) serves as an important installation for space and missile related materials science research. The ITF was established and began its research in spacecraft debris shielding in the early 1960s, then played a major role in the International Space Station debris shield development. As NASA became more interested in launch debris and in-flight impact concerns, the ITF grew to include research in a variety of impact genres. Collaborative partnerships with the DoD led to a wider range of impact capabilities being relocated to MSFC as a result of the closure of Particle Impact Facilities in Santa Barbara, California. The Particle Impact Facility had a 30 year history in providing evaluations of aerospace materials and components during flights through rain, ice, and solid particle environments at subsonic through hypersonic velocities. The facility s unique capabilities were deemed a "National Asset" by the DoD. The ITF now has capabilities including environmental, ballistic, and hypervelocity impact testing utilizing an array of air, powder, and two-stage light gas guns to accommodate a variety of projectile and target types and sizes. Numerous upgrades including new instrumentation, triggering circuitry, high speed photography, and optimized sabot designs have been implemented. Other recent research has included rain drop demise characterization tests to obtain data for inclusion in on-going model development. The current and proposed ITF capabilities range from rain to micrometeoroids allowing the widest test parameter range possible for materials investigations in support of space, atmospheric, and ground environments. These test capabilities including hydrometeor, single/multi-particle, ballistic gas guns, exploding wire gun, and light gas guns combined with Smooth Particle Hydrodynamics Code (SPHC) simulations represent the widest range of impact test capabilities in the country.

  19. View of Facility No. S359 (Seaplane Ramp 3), with Koolau ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of Facility No. S359 (Seaplane Ramp 3), with Koolau Mountain Range in background - U.S. Naval Base, Pearl Harbor, Seaplane Runways-1933 Type, South shore of Ford Island, near Lexington Boulevard, Pearl City, Honolulu County, HI

  20. 67. Photograph of line drawing. PLANS AND SECTIONS OF 20,000 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    67. Photograph of line drawing. PLANS AND SECTIONS OF 20,000 POUND MOTOR TEST AND LAUNCH FACILITY ('BLAST PIT'), DECEMBER 1945 - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  1. 68. Photograph of line drawing. SECTIONS AND DETAILS OF 20,000 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    68. Photograph of line drawing. SECTIONS AND DETAILS OF 20,000 POUND MOTOR TEST AND LAUNCH FACILITY ('BLAST PIT'), DECEMBER 1945 - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  2. 45 CFR 1614.3 - Range of activities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... assistance, research, advice and counsel, or the use of recipient facilities, libraries, computer assisted... bono basis through the provision of community legal education, training, technical assistance, research, advice and counsel; co-counseling arrangements; or the use of private law firm facilities, libraries...

  3. 45 CFR 1614.3 - Range of activities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... assistance, research, advice and counsel, or the use of recipient facilities, libraries, computer assisted... bono basis through the provision of community legal education, training, technical assistance, research, advice and counsel; co-counseling arrangements; or the use of private law firm facilities, libraries...

  4. 45 CFR 1614.3 - Range of activities.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... assistance, research, advice and counsel, or the use of recipient facilities, libraries, computer assisted... bono basis through the provision of community legal education, training, technical assistance, research, advice and counsel; co-counseling arrangements; or the use of private law firm facilities, libraries...

  5. Variations in Withdrawal, Return Flow, and Consumptive Use of Water in Ohio and Indiana, with Selected Data from Wisconsin, 1999-2004

    USGS Publications Warehouse

    Shaffer, Kimberly H.

    2009-01-01

    This report contains an analysis of water withdrawal and return-flow data for Ohio and withdrawal data for Indiana and Wisconsin to compute consumptive-use coefficients and to describe monthly variability of withdrawals and consumptive use. Concurrent data were available for most water-use categories from 1999 through 2004. Average monthly water withdrawals are discussed for a variety of water-use categories, and average water use per month is depicted graphically for Ohio, Indiana, and Wisconsin (public supply only). For most water-use categories, the summer months were those of highest withdrawal and highest consumptive use. For public supply, average monthly withdrawals ranged from 1,380 million gallons per day (Mgal/d) (November) to 1,620 Mgal/d (July) in Ohio, 621 Mgal/d (December) to 816 Mgal/d (July) in Indiana, and 515 Mgal/d (December) to 694 Mgal/d (July) in Wisconsin. Ohio and Indiana thermoelectric facilities had large increases in average monthly withdrawals in the summer months (5,520 Mgal/d in March to 7,510 Mgal/d in August for Indiana; 7,380 Mgal/d in February to 10,040 Mgal/d in July for Ohio), possibly because of increased electricity production in the summer, a need for additional cooling-water withdrawals when intake-water temperature is high, or use of different types of cooling methods during different times of the year. Average industrial withdrawals ranged from 2,220 Mgal/d (December) to 2,620 Mgal/d (August) in Indiana and from 707 Mgal/d (January) to 787 Mgal/d (August) in Ohio. The Ohio and Indiana irrigation data showed that most withdrawals were in May through October for golf courses, nurseries, and crop irrigation. Commercial water withdrawals ranged from 30.4 Mgal/d (January) to 65.0 Mgal/d (September) in Indiana and from 23.2 Mgal/d (November) to 49.5 Mgal/d (August) in Ohio; commercial facilities that have high water demand in Ohio and Indiana are medical facilities, schools, amusement facilities, wildlife facilities, large stores, colleges, correctional institutions, and national security facilities. Monthly livestock withdrawals were constant for Ohio but were more variable in Indiana and depended on whether the livestock facility operated on a seasonal schedule. Aquaculture withdrawals appeared to correlate with growing seasons and with aeration of ponds during the winter months. Mining withdrawals - specifically, those for nonmetallic mining - tended to be highest in April and may be related to dewatering. Consumptive use and consumptive-use coefficients were computed by two principal methods in this study: the return-flow and withdrawal method (RW; Ohio only) and the winter-base-rate method (WBR; Ohio, Indiana and Wisconsin). The WBR method was not suitable for the thermoelectric, industrial, irrigation, livestock, aquaculture, and mining water-use categories. The RW method was not used for public-supply facilities. A third method, the Standard Industrial Classification code method (SIC), was used only for certain industrial facilities. The public-supply annual average consumptive-use coefficient derived by use of the WBR methods ranged from 6 to 8 percent among Ohio, Indiana, and Wisconsin; the summer average consumptive-use coefficient was considerably higher, ranging from 16 to 20 percent. The commercial annual consumptive-use coefficient for both Ohio and Indiana was 30 percent by the WBR method, which fell within the Ohio annual median (17 percent) and annual average (42 percent) by the RW method. Thermoelectric consumptive use differs greatly by the type of cooling the facility uses; the Ohio annual median consumptive-use coefficient (RW method) was 2 percent for all thermoelectric facilities and facilities with multiple types of cooling, but exclusively once-through-cooling facilities had a median of 0 percent and exclusively closed-loop-cooling facilities had a median of 25 percent. Industrial consumptive-use coefficients varied by type of industry, as reflected by SIC code

  6. Requirements for temperature and species concentration measurements in microgravity combustion experiments

    NASA Technical Reports Server (NTRS)

    Ronney, Paul D.

    1988-01-01

    The requirements for a nonintrusive optical diagnostic facility for Space Station are assessed by examining the needs of current and future combustion experiments to be flown aboard the Space Station. Requirements for test section geometry and size, spatial and temporal resolution, species type and concentration range, and temperature range are reviewed. The feasibility of the development of this system is also addressed. The suitability of this facility to non-combustion experiments in gases and liquids is also considered.

  7. Validation of vision-based obstacle detection algorithms for low-altitude helicopter flight

    NASA Technical Reports Server (NTRS)

    Suorsa, Raymond; Sridhar, Banavar

    1991-01-01

    A validation facility being used at the NASA Ames Research Center is described which is aimed at testing vision based obstacle detection and range estimation algorithms suitable for low level helicopter flight. The facility is capable of processing hundreds of frames of calibrated multicamera 6 degree-of-freedom motion image sequencies, generating calibrated multicamera laboratory images using convenient window-based software, and viewing range estimation results from different algorithms along with truth data using powerful window-based visualization software.

  8. Langley Mach 4 scramjet test facility

    NASA Technical Reports Server (NTRS)

    Andrews, E. H., Jr.; Torrence, M. G.; Anderson, G. Y.; Northam, G. B.; Mackley, E. A.

    1985-01-01

    An engine test facility was constructed at the NASA Langley Research Center in support of a supersonic combustion ramjet (scramjet) technology development program. Hydrogen combustion in air with oxygen replenishment provides simulated air at Mach 4 flight velocity, pressure, and true total temperature for an altitude range from 57,000 to 86,000 feet. A facility nozzle with a 13 in square exit produces a Mach 3.5 free jet flow for engine propulsion tests. The facility is described and calibration results are presented which demonstrate the suitability of the test flow for conducting scramjet engine research.

  9. 63. Photograph of line drawing. SITE PLAN OF GANTRY CRANE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    63. Photograph of line drawing. SITE PLAN OF GANTRY CRANE TRACKS AND 20,000 POUND MOTOR TEST AND LAUNCH FACILITY ('BLAST PIT'), OCTOBER 1946 - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  10. Community Alternatives.

    ERIC Educational Resources Information Center

    Little (Arthur D.), Inc., Washington, DC.

    This resource booklet offers communities alternatives to juvenile detention and correctional facilities. The range of possibilities to be considered in lieu of incarceration is made available to planners, advocates, and decision-makers. The use of detention, correctional facilities and alternatives is a function of the social, political and…

  11. X-Ray Calibration Facility/Advanced Video Guidance Sensor Test

    NASA Technical Reports Server (NTRS)

    Johnston, N. A. S.; Howard, R. T.; Watson, D. W.

    2004-01-01

    The advanced video guidance sensor was tested in the X-Ray Calibration facility at Marshall Space Flight Center to establish performance during vacuum. Two sensors were tested and a timeline for each are presented. The sensor and test facility are discussed briefly. A new test stand was also developed. A table establishing sensor bias and spot size growth for several ranges is detailed along with testing anomalies.

  12. Changes in America's Public School Facilities: From School Year 1998-99 to School Year 2012-13. Stats in Brief. NCES 2016-074

    ERIC Educational Resources Information Center

    Bahr, Steven; Sparks, Dinah

    2016-01-01

    This Statistics in Brief summarizes the changes from the 1998-99 to the 2012-13 school years in the average age of public schools, ratings of satisfaction of the environmental quality of school facilities, the cost to put school buildings in good overall condition, and short-range plans to improve school facilities. In addition to providing…

  13. Measurements of methane emissions from natural gas gathering facilities and processing plants: measurement methods

    DOE PAGES

    Roscioli, J. R.; Yacovitch, T. I.; Floerchinger, C.; ...

    2015-05-07

    Increased natural gas production in recent years has spurred intense interest in methane (CH 4) emissions associated with its production, gathering, processing, transmission, and distribution. Gathering and processing facilities (G&P facilities) are unique in that the wide range of gas sources (shale, coal-bed, tight gas, conventional, etc.) results in a wide range of gas compositions, which in turn requires an array of technologies to prepare the gas for pipeline transmission and distribution. We present an overview and detailed description of the measurement method and analysis approach used during a 20-week field campaign studying CH 4 emissions from the natural gasmore » G&P facilities between October 2013 and April 2014. Dual-tracer flux measurements and on-site observations were used to address the magnitude and origins of CH 4 emissions from these facilities. The use of a second tracer as an internal standard revealed plume-specific uncertainties in the measured emission rates of 20–47%, depending upon plume classification. Furthermore, combining downwind methane, ethane (C 2H 6), carbon monoxide (CO), carbon dioxide (CO 2), and tracer gas measurements with on-site tracer gas release allows for quantification of facility emissions and in some cases a more detailed picture of source locations.« less

  14. NASA GRC's High Pressure Burner Rig Facility and Materials Test Capabilities

    NASA Technical Reports Server (NTRS)

    Robinson, R. Craig

    1999-01-01

    The High Pressure Burner Rig (HPBR) at NASA Glenn Research Center is a high-velocity. pressurized combustion test rig used for high-temperature environmental durability studies of advanced materials and components. The facility burns jet fuel and air in controlled ratios, simulating combustion gas chemistries and temperatures that are realistic to those in gas turbine engines. In addition, the test section is capable of simulating the pressures and gas velocities representative of today's aircraft. The HPBR provides a relatively inexpensive. yet sophisticated means for researchers to study the high-temperature oxidation of advanced materials. The facility has the unique capability of operating under both fuel-lean and fuel-rich gas mixtures. using a fume incinerator to eliminate any harmful byproduct emissions (CO, H2S) of rich-burn operation. Test samples are easily accessible for ongoing inspection and documentation of weight change, thickness, cracking, and other metrics. Temperature measurement is available in the form of both thermocouples and optical pyrometery. and the facility is equipped with quartz windows for observation and video taping. Operating conditions include: (1) 1.0 kg/sec (2.0 lbm/sec) combustion and secondary cooling airflow capability: (2) Equivalence ratios of 0.5- 1.0 (lean) to 1.5-2.0 (rich), with typically 10% H2O vapor pressure: (3) Gas temperatures ranging 700-1650 C (1300-3000 F): (4) Test pressures ranging 4-12 atmospheres: (5) Gas flow velocities ranging 10-30 m/s (50-100) ft/sec.: and (6) Cyclic and steady-state exposure capabilities. The facility has historically been used to test coupon-size materials. including metals and ceramics. However complex-shaped components have also been tested including cylinders, airfoils, and film-cooled end walls. The facility has also been used to develop thin-film temperature measurement sensors.

  15. Advanced human-machine interface for collaborative building control

    DOEpatents

    Zheng, Xianjun S.; Song, Zhen; Chen, Yanzi; Zhang, Shaopeng; Lu, Yan

    2015-08-11

    A system for collaborative energy management and control in a building, including an energy management controller, one or more occupant HMIs that supports two-way communication between building occupants and a facility manager, and between building occupants and the energy management controller, and a facility manager HMI that supports two-way communication between the facility manager and the building occupants, and between the facility manager and the energy management controller, in which the occupant HMI allows building occupants to provide temperature preferences to the facility manager and the energy management controller, and the facility manager HMI allows the facility manager to configure an energy policy for the building as a set of rules and to view occupants' aggregated temperature preferences, and the energy management controller determines an optimum temperature range that resolves conflicting occupant temperature preferences and occupant temperature preferences that conflict with the facility manager's energy policy for the building.

  16. Universal accessibility of "accessible" fitness and recreational facilities for persons with mobility disabilities.

    PubMed

    Arbour-Nicitopoulos, Kelly P; Ginis, Kathleen A Martin

    2011-01-01

    This study descriptively measured the universal accessibility of "accessible" fitness and recreational facilities for Ontarians living with mobility disabilities. The physical and social environments of 44 fitness and recreational facilities that identified as "accessible" were assessed using a modified version of the AIMFREE. None of the 44 facilities were completely accessible. Mean accessibility ratings ranged between 31 and 63 out of a possible 100. Overall, recreational facilities had higher accessibility scores than fitness centers, with significant differences found on professional support and training, entrance areas, and parking lot. A modest correlation was found between the availability of fitness programming and the overall accessibility of fitness-center specific facility areas. Overall, the physical and social environments of the 44 fitness and recreational facilities assessed were limited in their accessibility for persons with mobility disabilities. Future efforts should be directed at establishing and meeting universal accessibility guidelines for Canadian physical activity facilities.

  17. NASA Ames Arc Jets and Range, Capabilities for Planetary Entry

    NASA Technical Reports Server (NTRS)

    Fretter, Ernest F.

    2005-01-01

    NASA is pursuing innovative technologies and concepts as part of America's Vision for Space Exploration. The rapidly emerging field of nanotechnology has led to new concepts for multipurpose shields to prevent catastrophic loss of vehicles and crew against the triple threats of aeroheating during atmospheric entry, radiation (Solar and galactic cosmic rays) and Micrometorid/Orbital Debris (MMOD) strikes. One proposed concept is the Thermal Radiation Impact Protection System (TRIPS) using carbon nanotubes, hydrogenated carbon nanotubes, and ceramic coatings as a multi-use TPS. The Thermophysics Facilities Branch of the Space Technology Division at NASA Ames Research Center provides testing services for the development and validation of the present and future concepts being developed by NASA and national and International research firms. The Branch operates two key facilities - the Range Complex and the Arc Jets. The Ranges include both the Ames Vertical Gun Range (AVGR) and the Hypervelocity Free Flight (HFF) gas guns best suited for MMOD investigations. Test coupons can be installed in the AVGR or HFF and subjected to particle impacts from glass or metal particles from micron to _ inch (6.35-mm) diameters and at velocities from 5 to 8 kilometers per second. The facility can record high-speed data on film and provide damage assessment for analysis by the Principle Investigator or Ames personnel. Damaged articles can be installed in the Arc Jet facility for further testing to quantify the effects of damage on the heat shield s performance upon entry into atmospheric environments.

  18. An In-Port Feeding System for Shipboard Personnel. Volume 3. A personnel, Equipment, and Facility Evaluation of the Enlisted Dining Facilities at NAS North Island and NAVSTA San Diego.

    DTIC Science & Technology

    1981-05-01

    2.13 14.20 - Mixer S.D. 1.05 4.92 - Oven Proofer Range Glazes (bread) X 1.28 3.69 - Range S.D. 1.12 2.91 - Mixer Dough (breed) X 4.53 9.34 - Mixer SS.D...Steamer S.D. 0 - - Tomatoes X 16.00 17.00 - Range S.D. 21.21 12.73 - Steam kettle Fryer Desserts: Cookies X 1.92 10.97 - Range S.D. 1.21 1.85 - Mixer...88.30 Salad Dressing 550 24.07 51.21 Sandwiches 1,100 346.69 307.14 Beverages, cold 550 93.33 88.92 Dessert, cookies 550 15.05 67.19 Totals 550 599.94 lb

  19. On the development of an underground geoscience laboratory at Boulby in NE England (Invited)

    NASA Astrophysics Data System (ADS)

    Petley, D. N.; Rosser, N.; Barlow, J.; Brain, M. J.; Lim, M.; Sapsford, M.; Pybus, D.

    2009-12-01

    The Boulby Mine in NE England is a major potash extraction facility located in NE England. Opened in 1973, the mine extracts both potash and rock salt from Zechstein deposits located at a depth of about 1100 m below the land surface. For the last 20 years the mine has housed an important laboratory built to provide a base for Dark Matter research. However, in the last ten years the mine has progressively become been the site of research into geophysical and geological processes, primarily through a strategic partnership between the mine operators, Cleveland Potash Ltd, and the University of Durham. The site is now the base for an initial proof of concept project, funded by the Regional Development Agency One Northeast, to explore the viability of establishing a permanent geosciences research facility at Boulby. The vision is a facility that provides access for researchers into the range of geological environments at Boulby, extending from the coastal cliffs at the surface, through the access shafts to the deepest potash seams. The facility is designed to host research in geophysics, hydrology, geophysics, geomorphology, geochemistry, microbiology, rock mechanics, mining engineering, petrology and related fields. This proof of concept study has three key strategic aims: 1. To establish the range of uses of a research laboratory at Boulby and to determine the nature of the facilities required; 2. To initiate research programmes into: a. palaeoenvironmental reconstruction of the Zechstein deposits; b. the mechanics of the potash and halite rocks; and c. the mechanisms of failure of the coastal cliffs; 3. To construct an initial four serviced research caverns within the mine. The proof of concept stage of the project is intended to run until September 2010, with development of the facility being completed by 2015. However, the facility is currently in a position to host research projects across a wide range of disciplines.

  20. Housing Options for Older Adults: A Guide for Making Housing Decisions

    MedlinePlus

    ... from house sharing may have on eligibility for public benefits. ■ The effect of receiving Medicaid services on the ... facilities and whether the facility accepts individuals whose costs are paid by Medicaid. Benefits: Group housing options offer a wide range of ...

  1. Guidelines, site selection, and design for implementing truck parking/rest facilities in Chicago's south suburbs.

    DOT National Transportation Integrated Search

    2012-11-01

    This study proposes a network of overnight truck parking facilities in south suburban Chicago intended to : accomplish a wide range of federal, state, and local policy objectives. At the federal and state levels, this : reports policy objectives s...

  2. Development and use of hydrogen-air torches in an altitude facility

    NASA Technical Reports Server (NTRS)

    Lottig, Roy A.; Huber, Gary T.

    1993-01-01

    A hydrogen-air ignition torch concept that had been used successfully in two rocket engine test facilities to consume excess hydrogen in their exhausters at atmospheric conditions was experimentally evaluated and developed in an altitude test facility at NASA Lewis Research Center. The idea was to use several of these torches in conjunction with hydrogen detectors and dilution air to prevent excess accumulation of unburned hydrogen or mixtures of hydrogen and air exceeding the sea-level lower flammability limit in the altitude facility exhaust system during hydrogen-fueled propulsion system tests. The torches were evaluated for a range of fuel-to-air ratios from 0.09 to 0.39 and for a range of exit diameters from 19/64 to 49/64 in. From the results of these tests a torch geometry and a fuel-to-air ratio were selected that produced a reasonably sized torch exhaust flame for consumption of unburned hydrogen at altitude pressures from sea level to 4 psia.

  3. The Langley thermal protection system test facility: A description including design operating boundaries

    NASA Technical Reports Server (NTRS)

    Klich, G. F.

    1976-01-01

    A description of the Langley thermal protection system test facility is presented. This facility was designed to provide realistic environments and times for testing thermal protection systems proposed for use on high speed vehicles such as the space shuttle. Products from the combustion of methane-air-oxygen mixtures, having a maximum total enthalpy of 10.3 MJ/kg, are used as a test medium. Test panels with maximum dimensions of 61 cm x 91.4 cm are mounted in the side wall of the test region. Static pressures in the test region can range from .005 to .1 atm and calculated equilibrium temperatures of test panels range from 700 K to 1700 K. Test times can be as long as 1800 sec. Some experimental data obtained while using combustion products of methane-air mixtures are compared with theory, and calibration of the facility is being continued to verify calculated values of parameters which are within the design operating boundaries.

  4. Prevention and management of severe pre-eclampsia/eclampsia in Afghanistan

    PubMed Central

    2013-01-01

    Background An evidence-based strategy exists to reduce maternal morbidity and mortality associated with severe pre-eclampsia/eclampsia (PE/E), but it may be difficult to implement in low-resource settings. This study examines whether facilities that provide emergency obstetric and newborn care (EmONC) in Afghanistan have the capacity to manage severe PE/E cases. Methods A further analysis was conducted of the 2009–10 Afghanistan EmONC Needs Assessment. Assessors observed equipment and supplies available, and services provided at 78 of the 127 facilities offering comprehensive EmONC services and interviewed 224 providers. The providers also completed a written case scenario on severe PE/E. Descriptive statistics were used to summarize facility and provider characteristics. Student t-test, one-way ANOVA, and chi-square tests were performed to determine whether there were significant differences between facility types, doctors and midwives, and trained and untrained providers. Results The median number of severe PE/E cases in the past year was just 5 (range 0–42) at comprehensive health centers (CHCs) and district hospitals, compared with 44 (range 0–130) at provincial hospitals and 108 (range 32–540) at regional and specialized hospitals (p < 0.001). Most facilities had the drugs and supplies needed to treat severe PE/E, including the preferred anticonvulsant, magnesium sulfate (MgSO4). One-third of the smallest facilities and half of larger facilities reported administering a second-line drug, diazepam, in some cases. In the case scenario, 96% of doctors and 89% of midwives recognized that MgSO4 should be used to manage severe PE/E, but 42% of doctors and 58% of midwives also thought diazepam had a role to play. Providers who were trained on the use of MgSO4 scored significantly higher than untrained providers on six of 20 items in the case scenario. Providers at larger facilities significantly outscored those at smaller facilities on five items. There was a significant difference between doctors and midwives on only one item: continued use of anti-hypertensives after convulsions are controlled. Conclusions Drugs and supplies needed to treat severe PE/E are widely available at EmONC facilities in Afghanistan, but providers lack knowledge in some areas, especially concerning the use of MgSO4 and diazepam. Providers who have specialized training or work at larger facilities are better at managing cases of severe PE/E. The findings suggest a need to clarify service delivery guidelines, offer refresher training, and reinforce best practices with supervision and reinforcement. PMID:24119329

  5. Prevention and management of severe pre-eclampsia/eclampsia in Afghanistan.

    PubMed

    Kim, Young Mi; Ansari, Nasratullah; Kols, Adrienne; Tappis, Hannah; Currie, Sheena; Zainullah, Partamin; Bailey, Patricia; van Roosmalen, Jos; Stekelenburg, Jelle

    2013-10-12

    An evidence-based strategy exists to reduce maternal morbidity and mortality associated with severe pre-eclampsia/eclampsia (PE/E), but it may be difficult to implement in low-resource settings. This study examines whether facilities that provide emergency obstetric and newborn care (EmONC) in Afghanistan have the capacity to manage severe PE/E cases. A further analysis was conducted of the 2009-10 Afghanistan EmONC Needs Assessment. Assessors observed equipment and supplies available, and services provided at 78 of the 127 facilities offering comprehensive EmONC services and interviewed 224 providers. The providers also completed a written case scenario on severe PE/E. Descriptive statistics were used to summarize facility and provider characteristics. Student t-test, one-way ANOVA, and chi-square tests were performed to determine whether there were significant differences between facility types, doctors and midwives, and trained and untrained providers. The median number of severe PE/E cases in the past year was just 5 (range 0-42) at comprehensive health centers (CHCs) and district hospitals, compared with 44 (range 0-130) at provincial hospitals and 108 (range 32-540) at regional and specialized hospitals (p < 0.001). Most facilities had the drugs and supplies needed to treat severe PE/E, including the preferred anticonvulsant, magnesium sulfate (MgSO4). One-third of the smallest facilities and half of larger facilities reported administering a second-line drug, diazepam, in some cases. In the case scenario, 96% of doctors and 89% of midwives recognized that MgSO4 should be used to manage severe PE/E, but 42% of doctors and 58% of midwives also thought diazepam had a role to play. Providers who were trained on the use of MgSO4 scored significantly higher than untrained providers on six of 20 items in the case scenario. Providers at larger facilities significantly outscored those at smaller facilities on five items. There was a significant difference between doctors and midwives on only one item: continued use of anti-hypertensives after convulsions are controlled. Drugs and supplies needed to treat severe PE/E are widely available at EmONC facilities in Afghanistan, but providers lack knowledge in some areas, especially concerning the use of MgSO4 and diazepam. Providers who have specialized training or work at larger facilities are better at managing cases of severe PE/E. The findings suggest a need to clarify service delivery guidelines, offer refresher training, and reinforce best practices with supervision and reinforcement.

  6. Naturally occurring workplace facilities to increase the leisure time physical activity of workers: A propensity-score weighted population study.

    PubMed

    Biswas, Aviroop; Smith, Peter M; Gignac, Monique A M

    2018-06-01

    The benefit of providing access to physical activity facilities at or near work to support the leisure time physical activity (LTPA) of workers is uncertain. We examined the association between access to physical activity facilities at or near work and the LTPA of workers after adjusting for a range of individual and occupational characteristics. Data was obtained from 60,650 respondents to the 2007-2008 Canadian Community Health Survey. Participants were employed adults ≥18 years of age who had no long-term health condition which reduced their participation in physical activity. Latent class analysis determined naturally occurring combinations of physical activity facilities at or near work. Each combination was balanced by 19 individual and occupational covariate characteristics using inverse probability of treatment weights derived from propensity scores. The association between combinations of physical activity facilities at or near work on LTPA level was estimated by multinomial logistic regression. Five different combinations of physical activity facilities were available to respondents at or near work. Data were analyzed in 2017. All possible physical facilities increased the likelihood for LTPA (OR, 2.08, 95% CI, 1.03-4.20) and other combinations were also positively associated. Respondents with no physical activity facilities were characterized as having a low education, low income, high physically demanding work, poor health and mental health, non-white racial background, and being an immigrant. Access to supportive workplace environments can help workers be physically active. Future research should assess a range of personal, social and environmental factors that may be driving this relationship.

  7. Reconnecting fragmented sturgeon populations in North American rivers

    DOE PAGES

    Jager, Yetta; Forsythe, Patrick S.; McLaughlin, Robert L.; ...

    2016-02-24

    The majority of large North American rivers are fragmented by dams that interrupt migrations of wide-ranging fishes like sturgeons. Reconnecting habitat is viewed as an important means of protecting sturgeon species in U.S. rivers because these species have lost between 5% and 60% of their historical ranges. Unfortunately, facilities designed to pass other fishes have rarely worked well for sturgeons. The most successful passage facilities were sized appropriately for sturgeons and accommodated bottom-oriented species. For upstream passage, facilities with large entrances, full-depth guidance systems, large lifts, or wide fishways without obstructions or tight turns worked well. However, facilitating upstream migrationmore » is only half the battle. Broader recovery for linked sturgeon populations requires safe round-trip passage involving multiple dams. The most successful downstream passage facilities included nature-like fishways, large canal bypasses, and bottom-draw sluice gates. We outline an adaptive approach to implementing passage that begins with temporary programs and structures and monitors success both at the scale of individual fish at individual dams and the scale of metapopulations in a river basin. The challenge will be to learn from past efforts and reconnect North American sturgeon populations in a way that promotes range expansion and facilitates population recovery.« less

  8. Research and test facilities for development of technologies and experiments with commercial applications

    NASA Technical Reports Server (NTRS)

    1989-01-01

    One of NASA'S agency-wide goals is the commercial development of space. To further this goal NASA is implementing a policy whereby U.S. firms are encouraged to utilize NASA facilities to develop and test concepts having commercial potential. Goddard, in keeping with this policy, will make the facilities and capabilities described in this document available to private entities at a reduced cost and on a noninterference basis with internal NASA programs. Some of these facilities include: (1) the Vibration Test Facility; (2) the Battery Test Facility; (3) the Large Area Pulsed Solar Simulator Facility; (4) the High Voltage Testing Facility; (5) the Magnetic Field Component Test Facility; (6) the Spacecraft Magnetic Test Facility; (7) the High Capacity Centrifuge Facility; (8) the Acoustic Test Facility; (9) the Electromagnetic Interference Test Facility; (10) the Space Simulation Test Facility; (11) the Static/Dynamic Balance Facility; (12) the High Speed Centrifuge Facility; (13) the Optical Thin Film Deposition Facility; (14) the Gold Plating Facility; (15) the Paint Formulation and Application Laboratory; (16) the Propulsion Research Laboratory; (17) the Wallops Range Facility; (18) the Optical Instrument Assembly and Test Facility; (19) the Massively Parallel Processor Facility; (20) the X-Ray Diffraction and Scanning Auger Microscopy/Spectroscopy Laboratory; (21) the Parts Analysis Laboratory; (22) the Radiation Test Facility; (23) the Ainsworth Vacuum Balance Facility; (24) the Metallography Laboratory; (25) the Scanning Electron Microscope Laboratory; (26) the Organic Analysis Laboratory; (27) the Outgassing Test Facility; and (28) the Fatigue, Fracture Mechanics and Mechanical Testing Laboratory.

  9. Aerothermodynamic Testing of Aerocapture and Planetary Probe Geometries in Hypersonic Ballistic-Range Environments

    NASA Technical Reports Server (NTRS)

    Wilder, M. C.; Reda, D. C.; Bogdanoff, D. W.; Olejniczak, J.

    2005-01-01

    A viewgraph presentation on aerothermodynamic testing of aerocapture and planetary probe design methods in hypersonic ballistic range environments is shown. The topics include: 1) Ballistic Range Testing; 2) NASA-Ames Hypervelocity Free Flight Facility; and 3) Representative Results.

  10. NASA powered lift facility internally generated noise and its transmission to the acoustic far field

    NASA Technical Reports Server (NTRS)

    Huff, Ronald G.

    1988-01-01

    Noise tests of NASA Lewis Research Center's Powered Lift Facility (PLF) were performed to determine the frequency content of the internally generated noise that reaches the far field. The sources of the internally generated noise are the burner, elbows, valves, and flow turbulence. Tests over a range of nozzle pressure ratios from 1.2 to 3.5 using coherence analysis revealed that low frequency noise below 1200 Hz is transmitted through the nozzle. Broad banded peaks at 240 and 640 Hz were found in the transmitted noise. Aeroacoustic excitation effects are possible in this frequency range. The internal noise creates a noise floor that limits the amount of jet noise suppression that can be measured on the PLF and similar facilities.

  11. An Overview of the Antenna Measurement Facilities at the NASA Glenn Research Center

    NASA Astrophysics Data System (ADS)

    Lambert, Kevin M.; Anzic, Godfrey; Zakrajsek, Robert J.; Zaman, Afroz J.

    2002-10-01

    For the past twenty years, the NASA Glenn Research Center (formerly Lewis Research Center) in Cleveland, Ohio, has developed and maintained facilities for the evaluation of antennas. This effort has been in support of the work being done at the center in the research and development of space communication systems. The wide variety of antennas that have been considered for these systems resulted in a need for several types of antenna ranges at the Glenn Research Center. Four ranges, which are part of the Microwave Systems Laboratory, are the responsibility of the staff of the Applied RF Technology Branch. A general description of these ranges is provided in this paper.

  12. An Overview of the Antenna Measurement Facilities at the NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Lambert, Kevin M.; Anzic, Godfrey; Zakrajsek, Robert J.; Zaman, Afroz J.

    2002-01-01

    For the past twenty years, the NASA Glenn Research Center (formerly Lewis Research Center) in Cleveland, Ohio, has developed and maintained facilities for the evaluation of antennas. This effort has been in support of the work being done at the center in the research and development of space communication systems. The wide variety of antennas that have been considered for these systems resulted in a need for several types of antenna ranges at the Glenn Research Center. Four ranges, which are part of the Microwave Systems Laboratory, are the responsibility of the staff of the Applied RF Technology Branch. A general description of these ranges is provided in this paper.

  13. Hydrogen Infrastructure Testing and Research Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2017-04-10

    Learn about the Hydrogen Infrastructure Testing and Research Facility (HITRF), where NREL researchers are working on vehicle and hydrogen infrastructure projects that aim to enable more rapid inclusion of fuel cell and hydrogen technologies in the market to meet consumer and national goals for emissions reduction, performance, and energy security. As part of NREL’s Energy Systems Integration Facility (ESIF), the HITRF is designed for collaboration with a wide range of hydrogen, fuel cell, and transportation stakeholders.

  14. Development of a calibration equipment for spectrometer qualification

    NASA Astrophysics Data System (ADS)

    Michel, C.; Borguet, B.; Boueé, A.; Blain, P.; Deep, A.; Moreau, V.; François, M.; Maresi, L.; Myszkowiak, A.; Taccola, M.; Versluys, J.; Stockman, Y.

    2017-09-01

    With the development of new spectrometer concepts, it is required to adapt the calibration facilities to characterize correctly their performances. These spectro-imaging performances are mainly Modulation Transfer Function, spectral response, resolution and registration; polarization, straylight and radiometric calibration. The challenge of this calibration development is to achieve better performance than the item under test using mostly standard items. Because only the subsystem spectrometer needs to be calibrated, the calibration facility needs to simulate the geometrical "behaviours" of the imaging system. A trade-off study indicates that no commercial devices are able to fulfil completely all the requirements so that it was necessary to opt for an in home telecentric achromatic design. The proposed concept is based on an Offner design. This allows mainly to use simple spherical mirrors and to cover the spectral range. The spectral range is covered with a monochromator. Because of the large number of parameters to record the calibration facility is fully automatized. The performances of the calibration system have been verified by analysis and experimentally. Results achieved recently on a free-form grating Offner spectrometer demonstrate the capacities of this new calibration facility. In this paper, a full calibration facility is described, developed specifically for a new free-form spectro-imager.

  15. A Proactive Solution

    ERIC Educational Resources Information Center

    Hayes, Francis X.

    2006-01-01

    With more than 5,000 colleges, universities, and independent school campuses in the United States, ranging in size from two or three buildings to hundreds of facilities, it is no surprise that financial administrators and facilities departments have a difficult job keeping track of their campuses' physical needs. Managing, tracking, and planning…

  16. 22. V2 GANTRY, LAUNCH COMPLEX 33: GENERAL VIEW, LOOKING WEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. V-2 GANTRY, LAUNCH COMPLEX 33: GENERAL VIEW, LOOKING WEST AND UPWARD FROM APRON OF BLAST PIT, 20,000 POUND MOTOR TEST AND LAUNCH FACILITY - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  17. 21. V2 GANTRY, LAUNCH COMPLEX 33: VIEW OF CRANE WITH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. V-2 GANTRY, LAUNCH COMPLEX 33: VIEW OF CRANE WITH BLAST PIT OF 20,000 POUND MOTOR TEST AND LAUNCH FACILITY, IN FOREGROUND, LOOKING WEST - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  18. Evaluation of a laboratory quality assurance pilot programme for malaria diagnostics in low-transmission areas of Kenya, 2013.

    PubMed

    Wanja, Elizabeth; Achilla, Rachel; Obare, Peter; Adeny, Rose; Moseti, Caroline; Otieno, Victor; Morang'a, Collins; Murigi, Ephantus; Nyamuni, John; Monthei, Derek R; Ogutu, Bernhards; Buff, Ann M

    2017-05-25

    One objective of the Kenya National Malaria Strategy 2009-2017 is scaling access to prompt diagnosis and effective treatment. In 2013, a quality assurance (QA) pilot was implemented to improve accuracy of malaria diagnostics at selected health facilities in low-transmission counties of Kenya. Trends in malaria diagnostic and QA indicator performance during the pilot are described. From June to December 2013, 28 QA officers provided on-the-job training and mentoring for malaria microscopy, malaria rapid diagnostic tests and laboratory QA/quality control (QC) practices over four 1-day visits at 83 health facilities. QA officers observed and recorded laboratory conditions and practices and cross-checked blood slides for malaria parasite presence, and a portion of cross-checked slides were confirmed by reference laboratories. Eighty (96%) facilities completed the pilot. Among 315 personnel at pilot initiation, 13% (n = 40) reported malaria diagnostics training within the previous 12 months. Slide positivity ranged from 3 to 7%. Compared to the reference laboratory, microscopy sensitivity ranged from 53 to 96% and positive predictive value from 39 to 53% for facility staff and from 60 to 96% and 52 to 80%, respectively, for QA officers. Compared to reference, specificity ranged from 88 to 98% and negative predictive value from 98 to 99% for health-facility personnel and from 93 to 99% and 99%, respectively, for QA officers. The kappa value ranged from 0.48-0.66 for facility staff and 0.57-0.84 for QA officers compared to reference. The only significant test performance improvement observed for facility staff was for specificity from 88% (95% CI 85-90%) to 98% (95% CI 97-99%). QA/QC practices, including use of positive-control slides, internal and external slide cross-checking and recording of QA/QC activities, all increased significantly across the pilot (p < 0.001). Reference material availability also increased significantly; availability of six microscopy job aids and seven microscopy standard operating procedures increased by a mean of 32 percentage points (p < 0.001) and 38 percentage points (p < 0.001), respectively. Significant gains were observed in malaria QA/QC practices over the pilot. However, these advances did not translate into improved accuracy of malaria diagnostic performance perhaps because of the limited duration of the QA pilot implementation.

  19. Investigation of a Space Delta Technology Facility (SDTF) for Spacelab

    NASA Technical Reports Server (NTRS)

    Welch, J. D.

    1977-01-01

    The Space Data Technology Facility (SDTF) would have the role of supporting a wide range of data technology related demonstrations which might be performed on Spacelab. The SDTF design is incorporated primarily in one single width standardized Spacelab rack. It consists of various display, control and data handling components together with interfaces with the demonstration-specific equipment and Spacelab. To arrive at this design a wide range of data related technologies and potential demonstrations were also investigated. One demonstration concerned with online image rectification and registration was developed in some depth.

  20. The NASA Lewis Research Center Internal Fluid Mechanics Facility

    NASA Technical Reports Server (NTRS)

    Porro, A. R.; Hingst, W. R.; Wasserbauer, C. A.; Andrews, T. B.

    1991-01-01

    An experimental facility specifically designed to investigate internal fluid duct flows is described. It is built in a modular fashion so that a variety of internal flow test hardware can be installed in the facility with minimal facility reconfiguration. The facility and test hardware interfaces are discussed along with design constraints of future test hardware. The plenum flow conditioning approach is also detailed. Available instrumentation and data acquisition capabilities are discussed. The incoming flow quality was documented over the current facility operating range. The incoming flow produces well behaved turbulent boundary layers with a uniform core. For the calibration duct used, the boundary layers approached 10 percent of the duct radius. Freestream turbulence levels at the various operating conditions varied from 0.64 to 0.69 percent of the average freestream velocity.

  1. Availability of emergency obstetric care (EmOC) among public and private health facilities in rural northwest Bangladesh.

    PubMed

    Sikder, Shegufta S; Labrique, Alain B; Ali, Hasmot; Hanif, Abu A M; Klemm, Rolf D W; Mehra, Sucheta; West, Keith P; Christian, Parul

    2015-01-31

    Although safe motherhood strategies recommend that women seek timely care from health facilities for obstetric complications, few studies have described facility availability of emergency obstetric care (EmOC). We sought to describe and compare availability and readiness to provide EmOC among public and private health facilities commonly visited for pregnancy-related complications in two districts of northwest Bangladesh. We also described aspects of financial and geographic access to healthcare and key constraints to EmOC provision. Using data from a large population-based community trial, we identified and surveyed the 14 health facilities (7 public, 7 private) most frequently visited for obstetric complications and near misses as reported by women. Availability of EmOC was based on provision of medical services, assessed through clinician interviews and record review. Levels of EmOC availability were defined as basic or comprehensive. Readiness for EmOC provision was based on scores in four categories: staffing, equipment, laboratory capacity, and medicines. Readiness scores were calculated using unweighted averages. Costs of C-section procedures and geographic locations of facilities were described. Textual analysis was used to identify key constraints. The seven surveyed private facilities offered comprehensive EmOC compared to four of the seven public facilities. With 100% representing full readiness, mean EmOC readiness was 81% (range: 63%-91%) among surveyed private facilities compared to 67% (range: 48%-91%) in public facilities (p = 0.040). Surveyed public clinics had low scores on staffing and laboratory capacity (69%; 50%). The mean cost of the C-section procedure in private clinics was $77 (standard deviation: $16) and free in public facilities. The public sub-district facilities were the only facilities located in rural areas, with none providing comprehensive EmOC. Shortages in specialized staff were listed as the main barrier to EmOC provision in public facilities. Although EmOC availability and readiness was higher among the surveyed seven most commonly visited private clinics, public facilities appeared to be more affordable for C-section and more geographically accessible. Strategies to retain anesthesiologists and surgeons, such as non-financial incentives, are needed to improve EmOC provision in the public sector. Centralized blood banks are recommended to streamline safe blood acquisition for obstetric surgeries.

  2. 40 CFR 430.52 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... [Bisulfite liquor/surface condensers; BPT effluent limitations for papergrade sulfite facilities where blow... range of 5.0 to 9.0 at all times. Subpart E [Bisulfite liquor/barometric condensers; BPT effluent... [Acid sulfite liquor/surface condensers; BPT effluent limitations for papergrade sulfite facilities...

  3. 40 CFR 430.52 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... [Bisulfite liquor/surface condensers; BPT effluent limitations for papergrade sulfite facilities where blow... range of 5.0 to 9.0 at all times. Subpart E [Bisulfite liquor/barometric condensers; BPT effluent... [Acid sulfite liquor/surface condensers; BPT effluent limitations for papergrade sulfite facilities...

  4. 10 CFR 52.17 - Contents of applications; technical information.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... NUCLEAR POWER PLANTS Early Site Permits § 52.17 Contents of applications; technical information. (a) For..., and thermal power level of the facilities, or range of possible facilities, for which the site may be... forth the requirements for quality assurance programs for nuclear power plants. The description of the...

  5. 10 CFR 52.17 - Contents of applications; technical information.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... NUCLEAR POWER PLANTS Early Site Permits § 52.17 Contents of applications; technical information. (a) For..., and thermal power level of the facilities, or range of possible facilities, for which the site may be... forth the requirements for quality assurance programs for nuclear power plants. The description of the...

  6. 10 CFR 52.17 - Contents of applications; technical information.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... NUCLEAR POWER PLANTS Early Site Permits § 52.17 Contents of applications; technical information. (a) For..., and thermal power level of the facilities, or range of possible facilities, for which the site may be... forth the requirements for quality assurance programs for nuclear power plants. The description of the...

  7. 10 CFR 52.17 - Contents of applications; technical information.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... NUCLEAR POWER PLANTS Early Site Permits § 52.17 Contents of applications; technical information. (a) For..., and thermal power level of the facilities, or range of possible facilities, for which the site may be... forth the requirements for quality assurance programs for nuclear power plants. The description of the...

  8. Secondary Aluminum Processing Waste: Salt Cake Characterization and Reactivity

    EPA Science Inventory

    Thirty-nine salt cake samples were collected from 10 SAP facilities across the U.S. The facilities were identified by the Aluminum Association to cover a wide range of processes. Results suggest that while the percent metal leached from the salt cake was relatively low, the leac...

  9. The relationship between workplace environment and employee health behaviors in a South African workforce.

    PubMed

    Kolbe-Alexander, Tracy; Greyling, Michael; da Silva, Roseanne; Milner, Karen; Patel, Deepak; Wyper, Lauren; Beckowski, Meghan; Lambert, Estelle V; Goetzel, Ron

    2014-10-01

    To determine the relationship between the availability of wellness facilities at worksites and self-reported employee health behaviors (physical activity [PA] and nutrition [NUT]). Employers (n = 71) and employees (n = 11472) participated in the South African Healthy Company Index survey. The survey included self-reported clinical measures and lifestyle behaviors. A facility score was calculated, ranging from 0 to 100. Hierarchical linear models were used to calculate the relationship between facility scores and whether employees met PA and NUT guidelines. The mean total facility score was 58.5 ± 25.5. The number of facilities at each worksite accounted for 5.4% of the variance in PA among employees (r = 0.054; P = 0.036). Higher facility scores were associated with better NUT habits among employees. Employers providing wellness facilities are likely to have employees with better PA and NUT habits.

  10. Report of the committee on a commercially developed space facility

    NASA Technical Reports Server (NTRS)

    Shea, Joseph F.; Stever, H. Guyford; Cutter, W. Bowman, III; Demisch, Wolfgang H.; Fink, Daniel J.; Flax, Alexander H.; Gatos, Harry C.; Glicksman, Martin E.; Lanzerotti, Louis J.; Logsdon, John M., III

    1989-01-01

    Major facilities that could support significant microgravity research and applications activity are discussed. The ground-based facilities include drop towers, aircraft flying parabolic trajectories, and sounding rockets. Facilities that are intrinsically tied to the Space Shuttle range from Get-Away-Special canisters to Spacelab long modules. There are also orbital facilities which include recoverable capsules launched on expendable launch vehicles, free-flying spacecraft, and space stations. Some of these existing, planned, and proposed facilities are non-U.S. in origin, but potentially available to U.S. investigators. In addition, some are governmentally developed and operated whereas others are planned to be privately developed and/or operated. Tables are provided to show the facility, developer, duration, estimated gravity level, crew interaction, flight frequency, year available, power to payload, payload volume, and maximum payload mass. The potential of direct and indirect benefits of manufacturing in space are presented.

  11. Flow Disturbance Measurements in the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    King, Rudolph A.; Andino, Marlyn Y.; Melton, Latunia; Eppink, Jenna; Kegerise, Michael A.

    2013-01-01

    Recent flow measurements have been acquired in the National Transonic Facility to assess the test-section unsteady flow environment. The primary purpose of the test is to determine the feasibility of the facility to conduct laminar-flow-control testing and boundary-layer transition-sensitive testing at flight-relevant operating conditions throughout the transonic Mach number range. The facility can operate in two modes, warm and cryogenic test conditions for testing full and semispan-scaled models. Data were acquired for Mach and unit Reynolds numbers ranging from 0.2 less than or equal to M less than or equal to 0.95 and 3.3 × 10(exp 6) less than Re/m less than 220×10(exp 6) collectively at air and cryogenic conditions. Measurements were made in the test section using a survey rake that was populated with 19 probes. Roll polar data at selected conditions were obtained to look at the uniformity of the flow disturbance field in the test section. Data acquired included mean total temperatures, mean and fluctuating static/total pressures, and mean and fluctuating hot-wire measurements. This paper focuses primarily on the unsteady pressure and hot-wire results. Based on the current measurements and previous data, an assessment was made that the facility may be a suitable facility for ground-based demonstrations of laminar-flow technologies at flight-relevant conditions in the cryogenic mode.

  12. Cost (non)-recovery by platform technology facilities in the Bio21 Cluster.

    PubMed

    Gibbs, Gerard; Clark, Stella; Quinn, Julieanne; Gleeson, Mary Joy

    2010-04-01

    Platform technologies (PT) are techniques or tools that enable a range of scientific investigations and are critical to today's advanced technology research environment. Once installed, they require specialized staff for their operations, who in turn, provide expertise to researchers in designing appropriate experiments. Through this pipeline, research outputs are raised to the benefit of the researcher and the host institution. Platform facilities provide access to instrumentation and expertise for a wide range of users beyond the host institution, including other academic and industry users. To maximize the return on these substantial public investments, this wider access needs to be supported. The question of support and the mechanisms through which this occurs need to be established based on a greater understanding of how PT facilities operate. This investigation was aimed at understanding if and how platform facilities across the Bio21 Cluster meet operating costs. Our investigation found: 74% of platforms surveyed do not recover 100% of direct operating costs and are heavily subsidized by their home institution, which has a vested interest in maintaining the technology platform; platform managers play a major role in establishing the costs and pricing of the facility, normally in a collaborative process with a management committee or institutional accountant; and most facilities have a three-tier pricing structure recognizing internal academic, external academic, and commercial clients.

  13. Cost (Non)-Recovery by Platform Technology Facilities in the Bio21 Cluster

    PubMed Central

    Gibbs, Gerard; Clark, Stella; Quinn, JulieAnne; Gleeson, Mary Joy

    2010-01-01

    Platform technologies (PT) are techniques or tools that enable a range of scientific investigations and are critical to today's advanced technology research environment. Once installed, they require specialized staff for their operations, who in turn, provide expertise to researchers in designing appropriate experiments. Through this pipeline, research outputs are raised to the benefit of the researcher and the host institution.1 Platform facilities provide access to instrumentation and expertise for a wide range of users beyond the host institution, including other academic and industry users. To maximize the return on these substantial public investments, this wider access needs to be supported. The question of support and the mechanisms through which this occurs need to be established based on a greater understanding of how PT facilities operate. This investigation was aimed at understanding if and how platform facilities across the Bio21 Cluster meet operating costs. Our investigation found: 74% of platforms surveyed do not recover 100% of direct operating costs and are heavily subsidized by their home institution, which has a vested interest in maintaining the technology platform; platform managers play a major role in establishing the costs and pricing of the facility, normally in a collaborative process with a management committee or institutional accountant; and most facilities have a three-tier pricing structure recognizing internal academic, external academic, and commercial clients. PMID:20357980

  14. Particle size distributions of lead measured in battery manufacturing and secondary smelter facilities and implications in setting workplace lead exposure limits.

    PubMed

    Petito Boyce, Catherine; Sax, Sonja N; Cohen, Joel M

    2017-08-01

    Inhalation plays an important role in exposures to lead in airborne particulate matter in occupational settings, and particle size determines where and how much of airborne lead is deposited in the respiratory tract and how much is subsequently absorbed into the body. Although some occupational airborne lead particle size data have been published, limited information is available reflecting current workplace conditions in the U.S. To address this data gap, the Battery Council International (BCI) conducted workplace monitoring studies at nine lead acid battery manufacturing facilities (BMFs) and five secondary smelter facilities (SSFs) across the U.S. This article presents the results of the BCI studies focusing on the particle size distributions calculated from Personal Marple Impactor sampling data and particle deposition estimates in each of the three major respiratory tract regions derived using the Multiple-Path Particle Dosimetry model. The BCI data showed the presence of predominantly larger-sized particles in the work environments evaluated, with average mass median aerodynamic diameters (MMADs) ranging from 21-32 µm for the three BMF job categories and from 15-25 µm for the five SSF job categories tested. The BCI data also indicated that the percentage of lead mass measured at the sampled facilities in the submicron range (i.e., <1 µm, a particle size range associated with enhanced absorption of associated lead) was generally small. The estimated average percentages of lead mass in the submicron range for the tested job categories ranged from 0.8-3.3% at the BMFs and from 0.44-6.1% at the SSFs. Variability was observed in the particle size distributions across job categories and facilities, and sensitivity analyses were conducted to explore this variability. The BCI results were compared with results reported in the scientific literature. Screening-level analyses were also conducted to explore the overall degree of lead absorption potentially associated with the observed particle size distributions and to identify key issues associated with applying such data to set occupational exposure limits for lead.

  15. The large area high resolution gamma ray astrophysics facility - HR-GRAF

    NASA Astrophysics Data System (ADS)

    Fenyves, E. J.; Chaney, R. C.; Hoffman, J. H.; Cline, D. B.; Atac, M.; Park, J.; White, S. R.; Zych, A. D.; Tumer, Q. T.; Hughes, E. B.

    1990-03-01

    The long-term program is described in terms of its equipment, scientific objectives, and long-range scientific studies. A prototype of a space-based large-area high-resolution gamma-ray facility (HR-GRAF) is being developed to examine pointlike and diffuse gamma-ray sources in the range 1 MeV-100 GeV. The instrument for the facility is proposed to have high angular and energy resolution and very high sensitivity to permit the study of the proposed objects. The primary research targets include the mapping of galactic gamma radiation, observing the angular variations of diffuse gamma rays, and studying the Galactic center with particular emphasis on the hypothetical black hole. Also included in the research plans are obtaining data on gamma-ray bursters, investigating the transmission of gamma rays from cold dark matter, and studying nuclear gamma-ray lines.

  16. Guide for users of the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Fuller, D. E.; Gloss, B. B.; Nystrom, D.

    1981-01-01

    The National Transonic Facility (NTF) is a fan-driven, closed-circuit, continuous flow, pressurized wind tunnel. The test section is 2.5 m x 2.5 m and 7.62 m long with a slotted-wall configuration. The NTF will have a Mach number range from 0.2 to 1.2, with Reynolds number up to 120 10 to the sixth power at Mach 1 (based on a reference length of 0.25 m). The pressure range for the facility will be from 1 to about 9 bars (1 ban = 100 kPa), and the temperature can be varied from 340 to 78 K. This report provides potential users of the NTF with the information required for preliminary planning to test programs and for preliminary layout of models and model supports which may be used in such programs.

  17. An indoor air quality study of an alligator (Alligator mississippiensis) holding facility.

    PubMed

    Wilson, S C; Holder, H W; Martin, J M; Brasel, T L; Andriychuk, L A; Wu, C; Straus, D C; Aguilar, R

    2006-06-01

    An environmental microbiologic investigation was conducted in an alligator (Alligator mississippiensis) holding facility in a zoo in the southeastern U.S. The facility had housed five alligators between March 1999 and February 2005. In the exhibit, one alligator died and all experienced poor health. It was hypothesized that environmental microbial contamination was associated with these issues. Samples were collected for fungal identification and quantification, microcystin analysis, and airborne mycotoxins. Analyses of air and water were conducted and an examination of the heating, ventilation, and air-conditioning system (HVAC) for design, maintenance, and operating issues was made. Two control sites, a facility for false gharials (Tomistoma schlegelii) and an off-site alligator breeding facility, were also tested. Morbidity and mortality records were examined for all sites. Results showed that, compared to the control sites, the test alligator facility and its HVAC system were extensively contaminated with a range of fungi. Nearly all sampled surfaces featured fungal growth. There were also significantly higher counts of Penicillium/Aspergillus-like and Chrysosporium-like spores in the air (P < 0.004). The design, maintenance, and operation of the HVAC system were all inadequate, resulting in poorly conditioned and mold-contaminated air being introduced to the facility. Morbidity records revealed solitary pulmonary disorders over time in three alligators, with one dying as a result. The other two alligators suffered from general malaise and a range of nonspecific symptoms. The control facilities had no morbidity or mortality issues. In conclusion, although no causal links could be demonstrated because of the nature of the morbidity data, environmental mold contamination appeared to be associated with the history of morbidity and mortality in the alligator exhibit.

  18. Recent Upgrades at the Fermilab Test Beam Facility

    NASA Astrophysics Data System (ADS)

    Rominsky, Mandy

    2016-03-01

    The Fermilab Test Beam Facility is a world class facility for testing and characterizing particle detectors. The facility has been in operation since 2005 and has undergone significant upgrades in the last two years. A second beam line with cryogenic support has been added and the facility has adopted the MIDAS data acquisition system. The facility also recently added a cosmic telescope test stand and improved tracking capabilities. With two operational beam lines, the facility can deliver a variety of particle types and momenta ranging from 120 GeV protons in the primary beam line down to 200 MeV particles in the tertiary beam line. In addition, recent work has focused on analyzing the beam structure to provide users with information on the data they are collecting. With these improvements, the Fermilab Test Beam facility is capable of supporting High Energy physics applications as well as industry users. The upgrades will be discussed along with plans for future improvements.

  19. Characterization of LANDSAT Panels Using the NIST BRDF Scale from 1100 nm to 2500 nm

    NASA Technical Reports Server (NTRS)

    Markham, Brian; Tsai, Benjamin K.; Allen, David W.; Cooksey, Catherine; Yoon, Howard; Hanssen, Leonard; Zeng, Jinan; Fulton, Linda; Biggar, Stuart; Markham, Brian

    2010-01-01

    Many earth observing sensors depend on white diffuse reflectance standards to derive scales of radiance traceable to the St Despite the large number of Earth observing sensors that operate in the reflective solar region of the spectrum, there has been no direct method to provide NIST traceable BRDF measurements out to 2500 rim. Recent developments in detector technology have allowed the NIST reflectance measurement facility to expand the operating range to cover the 250 nm to 2500 nm range. The facility has been modified with and additional detector using a cooled extended range indium gallium arsenide (Extended InGaAs) detector. Measurements were made for two PTFE white diffuse reflectance standards over the 1100 nm to 2500 nm region at a 0' incident and 45' observation angle. These two panels will be used to support the OLI calibration activities. An independent means of verification was established using a NIST radiance transfer facility based on spectral irradiance, radiance standards and a diffuse reflectance plaque. An analysis on the results and associated uncertainties will be discussed.

  20. The National Transonic Facility: A Research Retrospective

    NASA Technical Reports Server (NTRS)

    Wahls, R. A.

    2001-01-01

    An overview of the National Transonic Facility (NTF) from a research utilization perspective is provided. The facility was born in the 1970s from an internationally recognized need for a high Reynolds number test capability based on previous experiences with preflight predictions of aerodynamic characteristics and an anticipated need in support of research and development for future aerospace vehicle systems. Selection of the cryogenic concept to meet the need, unique capabilities of the facility, and the eventual research utilization of the facility are discussed. The primary purpose of the paper is to expose the range of investigations that have used the NTF since being declared operational in late 1984; limited research results are included, though many more can be found in the references.

  1. Ames Hybrid Combustion Facility

    NASA Technical Reports Server (NTRS)

    Zilliac, Greg; Karabeyoglu, Mustafa A.; Cantwell, Brian; Hunt, Rusty; DeZilwa, Shane; Shoffstall, Mike; Soderman, Paul T.; Bencze, Daniel P. (Technical Monitor)

    2003-01-01

    The report summarizes the design, fabrication, safety features, environmental impact, and operation of the Ames Hybrid-Fuel Combustion Facility (HCF). The facility is used in conducting research into the scalability and combustion processes of advanced paraffin-based hybrid fuels for the purpose of assessing their applicability to practical rocket systems. The facility was designed to deliver gaseous oxygen at rates between 0.5 and 16.0 kg/sec to a combustion chamber operating at pressures ranging from 300 to 900. The required run times were of the order of 10 to 20 sec. The facility proved to be robust and reliable and has been used to generate a database of regression-rate measurements of paraffin at oxygen mass flux levels comparable to those of moderate-sized hybrid rocket motors.

  2. The solar physics Shuttle/Spacelab program and its relationship to studies of the flare build-up

    NASA Technical Reports Server (NTRS)

    Neupert, W. M.

    1976-01-01

    The main phase of solar physics (including flare-buildup) research on Shuttle/Spacelab during the 1980s centers around the use of facility instruments for multiple-user, multiple flight operations. Three main facilities are being considered: a meter-class optical telescope for visible and near-UV wavelengths, an EUV/XUV/soft X-ray facility, and a hard X-ray imaging facility (including a full-sun 5-600 keV spectrometer, a nuclear gamma ray spectrometer, and an X-ray polarimeter for the 5-100 keV range). Smaller instruments designed for specific observations and other classes of instruments such as solar monitors that are not on the facility level are also being considered.

  3. Management and Capability ot the Major Range and Test Facility Bases

    DTIC Science & Technology

    1995-07-27

    The audit objective was to evaluate management oversight provided to the test ranges and determine whether management oversight could be streamlined... The audit also evaluated whether program managers were procuring test resources that already existed at the test ranges. Management controls related to the objectives were also evaluated.

  4. Evaluation of Facility Management by Multivariate Statistics - Factor Analysis

    NASA Astrophysics Data System (ADS)

    Singovszki, Miloš; Vranayová, Zuzana

    2013-06-01

    Facility management is evolving, there is no exact than other sciences, although its development is fast forward. The knowledge and practical skills in facility management is not replaced, on the contrary, they complement each other. The existing low utilization of science in the field of facility management is mainly caused by the management of support activities are many variables and prevailing immediate reaction to the extraordinary situation arising from motives of those who have substantial experience and years of proven experience. Facility management is looking for a system that uses organized knowledge and will form the basis, which grows from a wide range of disciplines. Significant influence on its formation as a scientific discipline is the "structure, which follows strategy". The paper deals evaluate technology building as part of an facility management by multivariate statistic - factor analysis.

  5. The Development of an Information System Master Plan for the Pacific Missile Range Facility, Barking Sands, Hawaii

    DTIC Science & Technology

    1992-03-01

    sites and support facilities are located on the islands of Niihau and Oahu. Figure 1 depicts the overall layout of PMRF. [Ref. 4: p. 2] In addition...the HIANG facility at Kokee: • a wideband microwave system serving Niihau Island remotely controls operation of the AN/APS-134 surveillance radar, and...provides relay of digitized radar data, control data and voice between the remotely operated, unmanned radar on Niihau Island and Barking Sands

  6. Nuclear data measurements at the new NFS facility at GANIL

    NASA Astrophysics Data System (ADS)

    Gustavsson, C.; Pomp, S.; Scian, G.; Lecolley, F.-R.; Tippawan, U.; Watanabe, Y.

    2012-10-01

    The NFS (Neutrons For Science) facility is part of the SPRIAL 2 project at GANIL, Caen, France. The facility is currently under construction and the first beam is expected in early 2013. NFS will have a white neutron source covering the 1-40 MeV energy range with a neutron flux higher than comparable facilities. A quasi-mono-energetic neutron beam will also be available. In these energy ranges, especially above 14 MeV, there is a large demand for neutron-induced data for a wide range of applications involving dosimetry, medical therapy, single-event upsets in electronics and nuclear energy. Today, there are a few or no cross section data on reactions such as (n, fission), (n, xn), (n, p), (n, d) and (n, α). We propose to install experimental equipment for measuring neutron-induced light-charged particle production and fission relative to the H(n, p) cross section. Both the H(n, p) cross section and the fission cross section for 238U are important reference cross sections used as standards for many other experiments. Nuclear data for certain key elements, such as closed shell nuclei, are also of relevance for the development of nuclear reaction models. Our primary intention is to measure charged particle production (protons, deuterons and alphas) from 12C, 16O, 28Si and 56Fe and neutron-induced fission cross sections from 238U and 232Th.

  7. Temperature environment for 9975 packages stored in KAC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daugherty, W. L.

    Plutonium materials are stored in the K Area Complex (KAC) in shipping packages, typically the 9975 shipping package. In order to estimate realistic degradation rates for components within the shipping package (i.e. the fiberboard overpack and O-ring seals), it is necessary to understand actual facility temperatures, which can vary daily and seasonally. Relevant facility temperature data available from several periods throughout its operating history have been reviewed. The annual average temperature within the Crane Maintenance Area has ranged from approximately 70 to 74 °F, although there is significant seasonal variation and lesser variation among different locations within the facility. Themore » long-term average degradation rate for 9975 package components is very close to that expected if the component were to remain continually at the annual average temperature. This result remains valid for a wide range of activation energies (which describes the variation in degradation rate as the temperature changes), if the activation energy remains constant over the seasonal range of component temperatures. It is recommended that component degradation analyses and service life estimates incorporate these results. Specifically, it is proposed that future analyses assume an average facility ambient air temperature of 94 °F. This value is bounding for all packages, and includes margin for several factors such as increased temperatures within the storage arrays, the addition of more packages in the future, and future operational changes.« less

  8. What is the cost of providing outpatient HIV counseling and testing and antiretroviral therapy services in selected public health facilities in Nigeria?

    PubMed

    Aliyu, Husaina Bello; Chuku, Nkata Nwani; Kola-Jebutu, Abimbola; Abubakar, Zubaida; Torpey, Kwasi; Chabikuli, Otto Nzapfurundi

    2012-10-01

    Limited data on actual cost of providing HIV/AIDS services in Nigeria makes planning difficult. A study was conducted in 9 public health facilities supported by the Global HIV/AIDS Initiative Nigeria. The objective was to determine the cost of outpatient HIV Testing and Counseling (HTC) and antiretroviral therapy (ART) services per patient. Two tertiary and 7 secondary facilities were purposively selected across the six geopolitical regions. Facilities were distributed in urban and rural settings. Utilization and cost data for a 12-month period (January to December 2010) were analyzed. Cost elements included consumables, human resources, infrastructure, trainings, facility management, and Global HIV/AIDS Initiative Nigeria technical support. Total costs were apportioned based on percentage utilization by services, and unit costs were derived by dividing resource inputs by service outputs. Data were analyzed using Microsoft Excel 2003. A sensitivity analysis was also conducted for key assumptions. Mean costs for HTC and ART were US $7.4 and US $209.0, respectively. Costs were higher in Northern facilities (US $6.9, US $250.8), compared with Southern ones (US $6.7, US $194.7); and in tertiary facilities ($18.5, $338.4), compared with secondary ones ($6.3, $204.9). Major cost drivers for HTC and ART were human resources--ranging from 62% to 50%, and ARV drugs--ranging from 54% to 31%, respectively. Governments' ability to negotiate lower priced antiretroviral drugs will be central to reducing the cost of ART. Additionally, use of lower cadre staff to provide HTC will reduce costs and improves efficiency.

  9. Social Work Literature Searching: Current Issues with Databases and Online Search Engines

    ERIC Educational Resources Information Center

    McGinn, Tony; Taylor, Brian; McColgan, Mary; McQuilkan, Janice

    2016-01-01

    Objectives: To compare the performance of a range of search facilities; and to illustrate the execution of a comprehensive literature search for qualitative evidence in social work. Context: Developments in literature search methods and comparisons of search facilities help facilitate access to the best available evidence for social workers.…

  10. National remote computational flight research facility

    NASA Technical Reports Server (NTRS)

    Rediess, Herman A.

    1989-01-01

    The extension of the NASA Ames-Dryden remotely augmented vehicle (RAV) facility to accommodate flight testing of a hypersonic aircraft utilizing the continental United States as a test range is investigated. The development and demonstration of an automated flight test management system (ATMS) that uses expert system technology for flight test planning, scheduling, and execution is documented.

  11. Impacts of the Rural Turnaround on Rural Education.

    ERIC Educational Resources Information Center

    Ross, Peggy J.; Green, Bernal L.

    Facilities and staff, financing, administration, and social/behavioral problems are four areas of the educational systems of rural schools impacted by the rapid population growth resulting from the urban-to-rural migration begun in the 1970's and expected to last several decades. Overcrowding of facilities is a short-range problem for communities…

  12. The Development of a Measure of the Parenting Alliance.

    ERIC Educational Resources Information Center

    Abidin, Richard R.; Brunner, John F.

    The Parenting Alliance Inventory (PAI) was administered to 186 mothers and 75 fathers with a wide range of socioeconomic backgrounds who had at least one child between 2 and 6 years of age. Subjects were recruited from child care facilities, pediatric practices, and public recreational facilities in central Virginia. Extrafamilial child caregivers…

  13. Argonne Physics Division - ATLAS

    Science.gov Websites

    Strategic Plan (2014) ATLAS Gus Savard Guy Savard, Director of ATLAS Welcome to ATLAS, the Argonne Tandem users. ATLAS mission statement and strategic plan guide the operation of the facility. The strategic plan defines the facilities main goals and is aligned with the US Nuclear Physics long-range plan

  14. Long Range Development Plan, University of California, San Diego, October 1963.

    ERIC Educational Resources Information Center

    Alexander, Robert E.

    The academic and physical development plans of the University of California at San Diego are outlined. Facilities for 27,500 anticipated students are divided into twelve colleges of about 2300 students each. The twelve colleges are arranged into three clusters of four each, grouped around the central academic and administrative facilities, in…

  15. 40 CFR 408.175 - Standards of performance for new sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mechanized Salmon Processing Subcategory § 408.175 Standards of performance for new sources. (a) The...: (1) Any mechanized salmon processing facility located in population or processing centers including... grease 28 10 pH (1) (1) 1 Within the range 6.0 to 9.0. (2) Any mechanized salmon processing facility not...

  16. 40 CFR 408.175 - Standards of performance for new sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Mechanized Salmon Processing Subcategory § 408.175 Standards of performance for new sources. (a) The...: (1) Any mechanized salmon processing facility located in population or processing centers including... grease 28 10 pH (1) (1) 1 Within the range 6.0 to 9.0. (2) Any mechanized salmon processing facility not...

  17. Utilisation of real-scale renewable energy test facility for validation of generic wind turbine and wind power plant controller models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeni, Lorenzo; Hesselbæk, Bo; Bech, John

    This article presents an example of application of a modern test facility conceived for experiments regarding the integration of renewable energy in the power system. The capabilities of the test facility are used to validate dynamic simulation models of wind power plants and their controllers. The models are based on standard and generic blocks. The successful validation of events related to the control of active power (control phenomena in <10 Hz range, including frequency control and power oscillation damping) is described, demonstrating the capabilities of the test facility and drawing the track for future work and improvements.

  18. Advanced Hypervelocity Aerophysics Facility Workshop

    NASA Technical Reports Server (NTRS)

    Witcofski, Robert D. (Compiler); Scallion, William I. (Compiler)

    1989-01-01

    The primary objective of the workshop was to obtain a critical assessment of a concept for a large, advanced hypervelocity ballistic range test facility powered by an electromagnetic launcher, which was proposed by the Langley Research Center. It was concluded that the subject large-scale facility was feasible and would provide the required ground-based capability for performing tests at entry flight conditions (velocity and density) on large, complex, instrumented models. It was also concluded that advances in remote measurement techniques and particularly onboard model instrumentation, light-weight model construction techniques, and model electromagnetic launcher (EML) systems must be made before any commitment for the construction of such a facility can be made.

  19. Initial research program for the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Gloss, B. B.

    1984-01-01

    The construction and checkout of the National Transonic Facility (NTF) have been completed, and detailed calibration is now in progress. The initial NTF research program covers a wide range of study areas falling into three major elements: (1) the assessment of Reynolds number sensitivities for a broad range of configurations and flow phenomena; (2) validation of the ability of NTF to simulate full-scale aerodynamics; and (3) the development of test techniques for improved test simulations in existing wind tunnels. This paper, therefore, is a status report on these various elements of the initial NTF research program.

  20. An active interference projector for the electro-optical test facility

    NASA Astrophysics Data System (ADS)

    Crowe, D. G.; Nowak, T. M.

    1980-09-01

    A projection system is described which can simulate emissions from flares, muzzle-flashes, shellbursts, and other emissive agents which may degrade the performance of electro-optical systems in the 0.5-15 micron spectral range. The simulation capability obtained will allow the apparent radiance and temporal characteristics of muzzleflashes and shellbursts to be mimicked at simulated ranges as close as 23 m within the Electro-Optical Test Facility. This demonstrates that tests of electro-optical system performance in the presence of interferers can be performed under laboratory conditions with higher repeatability and lower cost than field tests.

  1. Capabilities of the Impact Testing Facility at Marshall Space Flight Center

    NASA Technical Reports Server (NTRS)

    Finchum, Andy; Nehls, Mary; Young, Whitney; Gray, Perry; Suggs, Bart; Lowrey, Nikki M.

    2011-01-01

    The test and analysis capabilities of the Impact Testing Facility at NASA's Marshall Space Flight Center are described. Nine different gun systems accommodate a wide range of projectile and target sizes and shapes at velocities from subsonic through hypersonic, to accomplish a broad range of ballistic and hypervelocity impact tests. These gun systems include ballistic and microballistic gas and powder guns, a two-stage light gas gun, and specialty guns for weather encounter studies. The ITF "rain gun" is the only hydrometeor impact gun known to be in existence in the United States that can provide single impact performance data with known raindrop sizes. Simulation of high velocity impact is available using the Smooth Particle Hydrodynamic Code. The Impact Testing Facility provides testing, custom test configuration design and fabrication, and analytical services for NASA, the Department of Defense, academic institutions, international space agencies, and private industry in a secure facility located at Marshall Space Flight Center, on the US Army's Redstone Arsenal in Huntsville, Alabama. This facility performs tests that are subject to International Traffic in Arms Regulations (ITAR) and DoD secret classified restrictions as well as proprietary and unrestricted tests for civil space agencies, academic institutions, and commercial aerospace and defense companies and their suppliers.

  2. Proposal for a slow positron facility at Jefferson National Laboratory

    NASA Astrophysics Data System (ADS)

    Mills, Allen P.

    2018-05-01

    One goal of the JPos-17 International Workshop on Physics with Positrons was to ascertain whether it would be a good idea to expand the mission of the Thomas Jefferson National Accelerator Facility (JLab) to include science with low energy (i.e. "slow") spin polarized positrons. It is probably true that experimentation with slow positrons would potentially have wide-ranging benefits comparable to those obtained with neutron and x-ray scattering, but it is certain that the full range of these benefits will never be fully available without an infrastructure comparable to that of existing neutron and x-ray facilities. The role for Jefferson Laboratory would therefore be to provide and maintain (1) a dedicated set of machines for making and manipulating high intensity, high brightness beams of polarized slow positrons; (2) a suite of unique and easily used instruments of wide utility that will make efficient use of the positrons; and (3) a group of on-site positron scientists to provide scientific leadership, instrument development, and user support. In this note some examples will be given of the science that might make a serious investment in a positron facility worthwhile. At the same time, the lessons learned from various proposed and successful positron facilities will be presented for consideration.

  3. Experimental Surface Pressure Data Obtained on 65 deg Delta Wing Across Reynolds Number and Mach Number Ranges. Volume 1; Sharp Leading Edge; [conducted in the Langley National Transonic Facility (NTF)

    NASA Technical Reports Server (NTRS)

    Chu, Julio; Luckring, James M.

    1996-01-01

    An experimental wind tunnel test of a 65 deg delta wing model with interchangeable leading edges was conducted in the Langley National Transonic Facility (NTF). The objective was to investigate the effects of Reynolds and Mach numbers on slender-wing leading-edge vortex flows with four values of wing leading-edge bluntness. Experimentally obtained pressure data are presented without analysis in tabulated and graphical formats across a Reynolds number range of 6 x 10(exp 6) to 36 x 10(exp 6) at a Mach number of 0.85 and across a Mach number range of 0.4 to 0.9 at a Reynolds number of 6 x 10(exp 6). Normal-force and pitching-moment coefficient plots for these Reynolds number and Mach number ranges are also presented.

  4. The use of new facility by means internal balance with sting support for wide range Angle of Attack aircraft

    NASA Astrophysics Data System (ADS)

    Subagyo; Daryanto, Yanto; Risnawan, Novan

    2018-04-01

    The development of facilities for the testing of wide range angle of attack aircraft in the wind tunnel at subsonic regime has done and implemented. Development required to meet the test at an angle of attack from -20 ° to 40 °. Testing the wide range angle of attack aircraft with a wide variation of the angle of attack become important needs. This can be done simply by using the sting support-equipped by internal balance to measure the forces and moments component aerodynamics. The results of development and use on the wide range angle of attack aircraft testing are aerodynamics characteristics in the form of the coefficient three components forces and the three components of the moment. A series of test aircraft was successfully carried out and the results are shown in the form of graphs of characteristic of aerodynamics at wind speed 70 m/s.

  5. Operations Plans for Anadromous Fish Production Facilities in the Columbia River Basin, Volume II of V; 1992 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hutchison, Bill

    1993-05-01

    Clearwater Hatchery is located on the north bank of the North Fork of the Clearwater River, downstream from Dworshak Dam. It is approximately 72 miles from Lower Granite Dam, and 504 miles from the mouth of the Columbia River. Site elevation is approximately 994 feet above sea level. The hatchery is staffed with 7 FTE's. Clearwater Hatchery has two pipelines from Dworshak Reservoir. One is attached to a floating platform and is capable of providing various temperatures at varying depths. The other is a stationary intake about 245 feet below the top of the dam. All water is gravity fedmore » to the hatchery. An l8 inch intake pipe provides an estimated 10 cfs with temperature remaining constant at approximately 40 F. The primary 42-inch intake pipe can draw water from 5 to 45 feet in depth with temperatures ranging from 55 to 60 F and 70 cfs of flow. The hatchery facility consists of 11 chinook raceways, 24 steelhead raceways, 2 adult holding ponds, a covered spawning area with 2 live wells and 60 concrete rearing vats. There are 40 double stacks of Heath-type incubators and each vat also has an incubation jar. All facility units are in excellent condition. Clearwater Hatchery also supports satellite facilities at Red River, Crooked River and Powell. The Red River satellite facility is located approximately 15 miles east of Elk City, Idaho. It is approximately 186 miles upstream from Lower Granite Dam and 618 miles from the mouth of the Columbia River. It was first built in 1974 by the Columbia River Project and then remodeled by the U.S. Army Corps of Engineers in 1986. Red River is supplied by gravity flow from an intake located at the bottom of the South Fork of Red River, 225 yards upstream from the facility. Water rights allow for 10 cfs and during low flows in the summer about 5 cfs is available. Temperatures range from 40 F in the spring to 71 F in early August. The facility consists of two adult holding ponds, a removable tripod and panel weir, and a rearing pond. All units are in good condition due to the recent remodeling. The Crooked River satellite facility is located 20 miles downstream of Red River. The trap is located 0.5 miles upstream of the mouth of Crooked River, a tributary of the South Fork of the Clearwater River. The rearing ponds are 10 miles upstream from the Crooked River adult trap. Crooked River water is supplied by gravity flow by an intake 200 yards upstream of the facility raceways. Water rights allow for 10 cfs at the rearing facility and 10 cfs at the trapping facility. Water temperatures range from 42 to 70 F. The trap and weir are located at the mouth of Crooked River. Ten miles upstream from the mouth are two raceways, a cleaning waste pond and final settling pond. All facility units are in good condition. The Powell satellite facility is located 122 miles east of the Clear-water Hatchery at the headwaters of the Lochsa River, the confluence of the Crooked Fork Creek and White Sands Creek. Powell is 192.5 miles from Lower Granite Dam and 624 miles from the mouth of the Columbia River. The Powell Facility receives gravity flow water from Walton Creek at a rate of 7 cfs with the intake being located 100 yards upstream from the facility. Powell also has a pumped supply from White Sands Creek at 3 cfs. Water temperature ranges from 45.8 to 50.2 F from the Walton Creek intake and 41 to 65 F from the White Sands pump station. The facility consists of one rearing pond, a diversion and intake screen, two adult holding ponds, a floating weir, and an open bay spawning shelter. All facility units are in good condition.« less

  6. Fact Sheet: Range Complex

    NASA Technical Reports Server (NTRS)

    Cornelson, C.; Fretter, E.

    2004-01-01

    NASA Ames has a long tradition in leadership with the use of ballistic ranges and shock tubes for the purpose of studying the physics and phenomena associated with hypervelocity flight. Cutting-edge areas of research run the gamut from aerodynamics, to impact physics, to flow-field structure and chemistry. This legacy of testing began in the NACA era of the 1940's with the Supersonic Free Flight Tunnel, and evolved dramatically up through the late 1950s with the pioneering work in the Ames Hypersonic Ballistic Range. The tradition continued in the mid-60s with the commissioning of the three newest facilities: the Ames Vertical Gun Range (AVGR) in 1964, the Hypervelocity Free Flight Facility (HFFF) in 1965 and the Electric Arc Shock Tube (EAST) in 1966. Today the Range Complex continues to provide unique and critical testing in support of the Nation's programs for planetary geology and geophysics; exobiology; solar system origins; earth atmospheric entry, planetary entry, and aerobraking vehicles; and various configurations for supersonic and hypersonic aircraft.

  7. Real-time range generation for ladar hardware-in-the-loop testing

    NASA Astrophysics Data System (ADS)

    Olson, Eric M.; Coker, Charles F.

    1996-05-01

    Real-time closed loop simulation of LADAR seekers in a hardware-in-the-loop facility can reduce program risk and cost. This paper discusses an implementation of real-time range imagery generated in a synthetic environment at the Kinetic Kill Vehicle Hardware-in-the Loop facility at Eglin AFB, for the stimulation of LADAR seekers and algorithms. The computer hardware platform used was a Silicon Graphics Incorporated Onyx Reality Engine. This computer contains graphics hardware, and is optimized for generating visible or infrared imagery in real-time. A by-produce of the rendering process, in the form of a depth buffer, is generated from all objects in view during its rendering process. The depth buffer is an array of integer values that contributes to the proper rendering of overlapping objects and can be converted to range values using a mathematical formula. This paper presents an optimized software approach to the generation of the scenes, calculation of the range values, and outputting the range data for a LADAR seeker.

  8. Automated acoustic localization and call association for vocalizing humpback whales on the Navy's Pacific Missile Range Facility.

    PubMed

    Helble, Tyler A; Ierley, Glenn R; D'Spain, Gerald L; Martin, Stephen W

    2015-01-01

    Time difference of arrival (TDOA) methods for acoustically localizing multiple marine mammals have been applied to recorded data from the Navy's Pacific Missile Range Facility in order to localize and track humpback whales. Modifications to established methods were necessary in order to simultaneously track multiple animals on the range faster than real-time and in a fully automated way, while minimizing the number of incorrect localizations. The resulting algorithms were run with no human intervention at computational speeds faster than the data recording speed on over forty days of acoustic recordings from the range, spanning multiple years. Spatial localizations based on correlating sequences of units originating from within the range produce estimates having a standard deviation typically 10 m or less (due primarily to TDOA measurement errors), and a bias of 20 m or less (due primarily to sound speed mismatch). An automated method for associating units to individual whales is presented, enabling automated humpback song analyses to be performed.

  9. Current Realities of Delivering Mammography Services in the Community: Do Challenges with Staffing and Scheduling Exist?

    PubMed Central

    D'Orsi, Carl; Tu, Shin-Ping; Nakano, Connie; Carney, Patricia A.; Abraham, Linn A.; Taplin, Stephen H.; Hendrick, R. Edward; Cutter, Gary R.; Berns, Eric; Barlow, William E.; Elmore, Joann G.

    2011-01-01

    PURPOSE To evaluate the current (2001–2002) capacity of community-based mammography facilities to deliver screening and diagnostic services in the United States. MATERIALS AND METHODS Institutional review board approvals and patient consent were obtained. A mailed survey was sent to 53 eligible mammography facilities in three states (Washington, New Hampshire, and Colorado). Survey questions assessed equipment and staffing availability, as well as appointment waiting times for screening and diagnostic mammography services. Criterion-related content and construct validity were obtained first by means of a national advisory committee of academic, scientific, and clinical colleagues in mammography that reviewed literature on existing surveys and second by pilot testing a series of draft surveys among community mammography facilities not inclusive of the study facilities. The final survey results were independently double entered into a relational database with programmed data checks. The data were sent encrypted by means of file transfer protocol to a central analytical center at Group Health Cooperative. A two-sided P value with α = .05 was considered to show statistical significance in all analyses. RESULTS Forty-five of 53 eligible mammography facilities (85%) returned the survey. Shortages of radiologists relative to the mammographic volume were found in 44% of mammography facilities overall, with shortages of radiologists higher in not-for-profit versus for-profit facilities (60% vs 28% reported). Shortages of Mammography Quality Standards Act–qualified technologists were reported by 20% of facilities, with 46% reporting some level of difficulty in maintaining qualified technologists. Waiting times for diagnostic mammography ranged from less than 1 week to 4 weeks, with 85% performed within 1 week. Waiting times for screening mammography ranged from less than 1 week to 8 weeks, with 59% performed between 1 week and 4 weeks. Waiting times for both diagnostic and screening services were two to three times higher in high-volume compared with low-volume facilities. CONCLUSION Survey results show shortages of radiologists and certified mammography technologists. PMID:15798153

  10. Review of emergency obstetric care interventions in health facilities in the Upper East Region of Ghana: a questionnaire survey.

    PubMed

    Kyei-Onanjiri, Minerva; Carolan-Olah, Mary; Awoonor-Williams, John Koku; McCann, Terence V

    2018-03-15

    Maternal morbidity and mortality is most prevalent in resource-poor settings such as sub-Saharan Africa and southern Asia. In sub-Saharan Africa, Ghana is one of the countries still facing particular challenges in reducing its maternal morbidity and mortality. Access to emergency obstetric care (EmOC) interventions has been identified as a means of improving maternal health outcomes. Assessing the range of interventions provided in health facilities is, therefore, important in determining capacity to treat obstetric emergencies. The aim of this study was to examine the availability of emergency obstetric care interventions in the Upper East Region of Ghana. A cross-sectional survey of 120 health facilities was undertaken. Status of emergency obstetric care was assessed through an interviewer administered questionnaire to directors/in-charge officers of maternity care units in selected facilities. Data were analysed using descriptive statistics. Eighty per cent of health facilities did not meet the criteria for provision of emergency obstetric care. Comparatively, private health facilities generally provided EmOC interventions less frequently than public health facilities. Other challenges identified include inadequate skill mix of maternity health personnel, poor referral processes, a lack of reliable communication systems and poor emergency transport systems. Multiple factors combine to limit women's access to a range of essential maternal health services. The availability of EmOC interventions was found to be low across the region; however, EmOC facilities could be increased by nearly one-third through modest investments in some existing facilities. Also, the key challenges identified in this study can be improved by enhancing pre-existing health system structures such as Community-based Health Planning and Services (CHPS), training more midwifery personnel, strengthening in-service training and implementation of referral audits as part of health service monitoring. Gaps in availability of EmOC interventions, skilled personnel and referral processes must be tackled in order to improve obstetric outcomes.

  11. The Diesel Exhaust in Miners Study: IV. Estimating historical exposures to diesel exhaust in underground non-metal mining facilities.

    PubMed

    Vermeulen, Roel; Coble, Joseph B; Lubin, Jay H; Portengen, Lützen; Blair, Aaron; Attfield, Michael D; Silverman, Debra T; Stewart, Patricia A

    2010-10-01

    We developed quantitative estimates of historical exposures to respirable elemental carbon (REC) for an epidemiologic study of mortality, including lung cancer, among diesel-exposed miners at eight non-metal mining facilities [the Diesel Exhaust in Miners Study (DEMS)]. Because there were no historical measurements of diesel exhaust (DE), historical REC (a component of DE) levels were estimated based on REC data from monitoring surveys conducted in 1998-2001 as part of the DEMS investigation. These values were adjusted for underground workers by carbon monoxide (CO) concentration trends in the mines derived from models of historical CO (another DE component) measurements and DE determinants such as engine horsepower (HP; 1 HP = 0.746 kW) and mine ventilation. CO was chosen to estimate historical changes because it was the most frequently measured DE component in our study facilities and it was found to correlate with REC exposure. Databases were constructed by facility and year with air sampling data and with information on the total rate of airflow exhausted from the underground operations in cubic feet per minute (CFM) (1 CFM = 0.0283 m³ min⁻¹), HP of the diesel equipment in use (ADJ HP), and other possible determinants. The ADJ HP purchased after 1990 (ADJ HP₁₉₉₀(+)) was also included to account for lower emissions from newer, cleaner engines. Facility-specific CO levels, relative to those in the DEMS survey year for each year back to the start of dieselization (1947-1967 depending on facility), were predicted based on models of observed CO concentrations and log-transformed (Ln) ADJ HP/CFM and Ln(ADJ HP₁₉₉₀(+)). The resulting temporal trends in relative CO levels were then multiplied by facility/department/job-specific REC estimates derived from the DEMS surveys personal measurements to obtain historical facility/department/job/year-specific REC exposure estimates. The facility-specific temporal trends of CO levels (and thus the REC estimates) generated from these models indicated that CO concentrations had been generally greater in the past than during the 1998-2001 DEMS surveys, with the highest levels ranging from 100 to 685% greater (median: 300%). These levels generally occurred between 1970 and the early 1980s. A comparison of the CO facility-specific model predictions with CO air concentration measurements from a 1976-1977 survey external to the modeling showed that our model predictions were slightly lower than those observed (median relative difference of 29%; range across facilities: 49 to -25%). In summary, we successfully modeled past CO concentration levels using selected determinants of DE exposure to derive retrospective estimates of REC exposure. The results suggested large variations in REC exposure levels both between and within the underground operations of the facilities and over time. These REC exposure estimates were in a plausible range and were used in the investigation of exposure-response relationships in epidemiologic analyses.

  12. RF-Plasma Source Commissioning in Indian Negative Ion Facility

    NASA Astrophysics Data System (ADS)

    Singh, M. J.; Bandyopadhyay, M.; Bansal, G.; Gahlaut, A.; Soni, J.; Kumar, Sunil; Pandya, K.; Parmar, K. G.; Sonara, J.; Yadava, Ratnakar; Chakraborty, A. K.; Kraus, W.; Heinemann, B.; Riedl, R.; Obermayer, S.; Martens, C.; Franzen, P.; Fantz, U.

    2011-09-01

    The Indian program of the RF based negative ion source has started off with the commissioning of ROBIN, the inductively coupled RF based negative ion source facility under establishment at Institute for Plasma research (IPR), India. The facility is being developed under a technology transfer agreement with IPP Garching. It consists of a single RF driver based beam source (BATMAN replica) coupled to a 100 kW, 1 MHz RF generator with a self excited oscillator, through a matching network, for plasma production and ion extraction and acceleration. The delivery of the RF generator and the RF plasma source without the accelerator, has enabled initiation of plasma production experiments. The recent experimental campaign has established the matching circuit parameters that result in plasma production with density in the range of 0.5-1×1018/m3, at operational gas pressures ranging between 0.4-1 Pa. Various configurations of the matching network have been experimented upon to obtain a stable operation of the set up for RF powers ranging between 25-85 kW and pulse lengths ranging between 4-20 s. It has been observed that the range of the parameters of the matching circuit, over which the frequency of the power supply is stable, is narrow and further experiments with increased number of turns in the coil are in the pipeline to see if the range can be widened. In this paper, the description of the experimental system and the commissioning data related to the optimisation of the various parameters of the matching network, to obtain stable plasma of required density, are presented and discussed.

  13. Noise in a Laboratory Animal Facility from the Human and Mouse Perspectives

    PubMed Central

    Reynolds, Randall P; Kinard, Will L; Degraff, Jesse J; Leverage, Ned; Norton, John N

    2010-01-01

    The current study was performed to understand the level of sound produced by ventilated racks, animal transfer stations, and construction equipment that mice in ventilated cages hear relative to what humans would hear in the same environment. Although the ventilated rack and animal transfer station both produced sound pressure levels above the ambient level within the human hearing range, the sound pressure levels within the mouse hearing range did not increase above ambient noise from either noise source. When various types of construction equipment were used 3 ft from the ventilated rack, the sound pressure level within the mouse hearing range was increased but to a lesser degree for each implement than were the sound pressure levels within the human hearing range. At more distant locations within the animal facility, sound pressure levels from the large jackhammer within the mouse hearing range decreased much more rapidly than did those in the human hearing range, indicating that less of the sound is perceived by mice than by humans. The relatively high proportion of low-frequency sound produced by the shot blaster, used without the metal shot that it normally uses to clean concrete, increased the sound pressure level above the ambient level for humans but did not increase sound pressure levels above ambient noise for mice at locations greater than 3 ft from inside of the cage, where sound was measured. This study demonstrates that sound clearly audible to humans in the animal facility may be perceived to a lesser degree or not at all by mice, because of the frequency content of the sound. PMID:20858361

  14. How do rats respond to playing radio in the animal facility?

    PubMed

    Krohn, Thomas C; Salling, Bo; Hansen, Axel Kornerup

    2011-07-01

    In the animal facility, a range of different sounds are present. On the one hand, rats and humans will regard sound and noise differently even within the audible range, but on the other hand mice and rats being very adaptable to the environment may adapt to living in a noisy facility with e.g. a radio playing. It was the aim of the present study to investigate whether two different strains of rats had different preferences for different kinds of sound patterns, including radio, and to get an indication of whether they are able to distinguish between different sound patterns. The present preference study revealed that rats were able to distinguish between different sound patterns. They showed a clear preference for silence to anything else, which may be taken as an indication that they feel disturbed by the sound from the speaker.

  15. Analysis of ORNL site temperature and humidity data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Willis, B.E.

    1989-08-01

    The Advanced Neutron Source (ANS) is planned as a new state-of-the-art facility for neutron research and is currently undergoing conceptual design at the Oak Ridge National Laboratory (ORNL). The current concept calls for a nuclear research reactor with an operating power near 350 MW and extensive experiment and user support facilities. Analyses have been undertaken to determine an acceptable design basis wet-bulb temperature range for the facility. Comparisons are drawn with the design wet-bulb temperature previously used for the High Flux Isotope Reactor (HFIR), which is located on an adjacent site a Oak Ridge. This report explains the importance ofmore » wet-bulb temperature to the reactor cooling system performance, and describes the analysis of available meteorological data, and presents the results and the recommendations for a wet-bulb temperature range for use as a part of the plant design basis conditions. 1 ref., 6 figs.« less

  16. Comparison of medicine availability measurements at health facilities: evidence from Service Provision Assessment surveys in five sub-Saharan African countries.

    PubMed

    Choi, Yoonjoung; Ametepi, Paul

    2013-07-09

    With growing emphasis on health systems strengthening in global health, various health facility assessment methods have been used increasingly to measure medicine and commodity availability. However, few studies have systematically compared estimates of availability based on different definitions. The objective of this study was to compare estimates of medicine availability based on different definitions. A secondary data analysis was conducted using data from the Service Provision Assessment (SPA)--a nationally representative sample survey of health facilities--conducted in five countries: Kenya SPA 2010, Namibia SPA 2009, Rwanda SPA 2007, Tanzania SPA 2006, and Uganda SPA 2007. For 32 medicines, percent of facilities having the medicine were estimated using five definitions: four for current availability and one for six-month period availability. 'Observed availability of at least one valid unit' was used as a reference definition, and ratios between the reference and each of the other four estimates were calculated. Summary statistics of the ratios among the 32 medicines were calculated by country. The ratios were compared further between public and non-public facilities within each country. Across five countries, compared to current observed availability of at least one valid unit, 'reported availability without observation' was on average 6% higher (ranging from 3% in Rwanda to 8% in Namibia), 'observed availability where all units were valid' was 11% lower (ranging from 2% in Tanzania to 19% in Uganda), and 'six-month period availability' was 14% lower (ranging from 5% in Namibia to 25% in Uganda). Medicine availability estimates vary substantially across definitions, and need to be interpreted with careful consideration of the methods used.

  17. Facility effluent monitoring plan for the plutonium uranium extraction facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiegand, D.L.

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of themore » effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years.« less

  18. A User's Guide for the Spacecraft Fire Safety Facility

    NASA Technical Reports Server (NTRS)

    Goldmeer, Jeffrey S.

    2000-01-01

    The Spacecraft Fire Safety Facility (SFSF) is a test facility that can be flown on NASA's reduced gravity aircraft to perform various types of combustion experiments under a variety of experimental conditions. To date, this facility has flown numerous times on the aircraft and has been used to perform experiments ranging from an examination of the effects transient depressurization on combustion, to ignition and flame spread. A list of pubfications/presentations based on experiments performed in the SFSF is included in the reference section. This facility consists of five main subsystems: combustion chamber, sample holders, gas flow system, imaging system, and the data acquisition/control system. Each of these subsystems will be reviewed in more detail. These subsystems provide the experiment operator with the ability to monitor and/or control numerous experimental parameters.

  19. A facility for testing 10 to 100-kWe space power reactors

    NASA Astrophysics Data System (ADS)

    Carlson, William F.; Bitten, Ernest J.

    1993-01-01

    This paper describes an existing facility that could be used in a cost-effective manner to test space power reactors in the 10 to 100-kWe range before launch. The facility has been designed to conduct full power tests of 100-kWe SP-100 reactor systems and already has the structural features that would be required for lower power testing. The paper describes a reasonable scenario starting with the acceptance at the test site of the unfueled reactor assembly and the separately shipped nuclear fuel. After fueling the reactor and installing it in the facility, cold critical tests are performed, and the reactor is then shipped to the launch site. The availability of this facility represents a cost-effective means of performing the required prelaunch test program.

  20. The Granite Mountain Atmospheric Sciences Testbed (GMAST): A Facility for Long Term Complex Terrain Airflow Studies

    NASA Astrophysics Data System (ADS)

    Zajic, D.; Pace, J. C.; Whiteman, C. D.; Hoch, S.

    2011-12-01

    This presentation describes a new facility at Dugway Proving Ground (DPG), Utah that can be used to study airflow over complex terrain, and to evaluate how airflow over a mountain barrier affects wind patterns over adjacent flatter terrain. DPG's primary mission is to conduct testing, training, and operational assessments of chemical and biological weapon systems. These operations require very precise weather forecasts. Most test operations at DPG are conducted on fairly flat test ranges having uniform surface cover, where airflow patterns are generally well-understood. However, the DPG test ranges are located alongside large, isolated mountains, most notably Granite Mountain, Camelback Mountain, and the Cedar Mountains. Airflows generated over, or influenced by, these mountains can affect wind patterns on the test ranges. The new facility, the Granite Mountain Atmospheric Sciences Testbed, or GMAST, is designed to facilitate studies of airflow interactions with topography. This facility will benefit DPG by improving understanding of how mountain airflows interact with the test range conditions. A core infrastructure of weather sensors around and on Granite Mountain has been developed including instrumented towers and remote sensors, along with automated data collection and archival systems. GMAST is expected to be in operation for a number of years and will provide a reference domain for mountain meteorology studies, with data useful for analysts, modelers and theoreticians. Visiting scientists are encouraged to collaborate with DPG personnel to utilize this valuable scientific resource and to add further equipment and scientific designs for both short-term and long-term atmospheric studies. Several of the upcoming MATERHORN (MountAin TERrain atmospHeric mOdeling and obseRvatioNs) project field tests will be conducted at DPG, giving an example of GMAST utilization and collaboration between DPG and visiting scientists.

  1. A Guide to Federal Financial Aid for Dental Health: Services, Facilities, Training, and Research.

    ERIC Educational Resources Information Center

    National Institutes of Health (DHEW), Bethesda, MD. Div. of Dental Health.

    Federal financial aid is available for a wide range of dental activities, including the provision of services, construction of facilities, education and training of professional and auxiliary personnel, and the conduct of research and demonstration projects. This publication contains a brief description of the purpose of each federal aid program,…

  2. 40 CFR 408.172 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CATEGORY Alaskan Mechanized Salmon Processing Subcategory § 408.172 Effluent limitations guidelines... available (BPT): (a) Any mechanized salmon processing facility located in population or processing centers... grease 29 11 pH (1) (1) 1 Within the range 6.0 to 9.0. (b) Any mechanized salmon processing facility not...

  3. 40 CFR 408.172 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CATEGORY Alaskan Mechanized Salmon Processing Subcategory § 408.172 Effluent limitations guidelines... available (BPT): (a) Any mechanized salmon processing facility located in population or processing centers... grease 29 11 pH (1) (1) 1 Within the range 6.0 to 9.0. (b) Any mechanized salmon processing facility not...

  4. Final Environmental Assessment: Construction of Maintenance and Storage Facility, Perimeter Fence Upgrade and Demolition of Three Buildings and Two Structures Gila River Air Force Space Surveillance Station Arizona

    DTIC Science & Technology

    2012-11-01

    Estrella mountain range is approximately six miles west of the Installation and the Sacaton mountain range lie approximate- ly six miles to the southeast...Structures 3-4 Figure 5. Geological Map of Gila River AFSSS and Vicinity Sierra Estrella Range Sacaton Range EA — Construct Maintenance & Storage

  5. BIOPACK: the ground controlled late access biological research facility.

    PubMed

    van Loon, Jack J W A

    2004-03-01

    Future Space Shuttle flights shall be characterized by activities necessary to further build the International Space Station, ISS. During these missions limited resources are available to conduct biological experiments in space. The Shuttles' Middeck is a very suitable place to conduct science during the ISS assembly missions or dedicated science missions. The BIOPACK, which flew its first mission during the STS-107, provides a versatile Middeck Locker based research tool for gravitational biology studies. The core facility occupies the space of only two Middeck Lockers. Experiment temperatures are controlled for bacteria, plant, invertebrate and mammalian cultures. Gravity levels and profiles can be set ranging from 0 to 2.0 x g on three independent centrifuges. This provides the experimenter with a 1.0 x g on-board reference and intermediate hypogravity and hypergravity data points to investigate e.g. threshold levels in biological responses. Temperature sensitive items can be stored in the facilities' -10 degrees C and +4 degrees C stowage areas. During STS-107 the facility also included a small glovebox (GBX) and passive temperature controlled units (PTCU). The GBX provides the experimenter with two extra levels of containment for safe sample handling. This biological research facility is a late access (L-10 hrs) laboratory, which, when reaching orbit, could automatically be starting up reducing important experiment lag-time and valuable crew time. The system is completely telecommanded when needed. During flight system parameters like temperatures, centrifuge speeds, experiment commanding or sensor readouts can be monitored and changed when needed. Although ISS provides a wide range of research facilities there is still need for an STS-based late access facility such as the BIOPACK providing experimenters with a very versatile research cabinet for biological experiments under microgravity and in-flight control conditions.

  6. Institutional Long Range Planning.

    ERIC Educational Resources Information Center

    Caldwell Community Coll. and Technical Inst., Lenoir, NC.

    Long-range institutional planning has been in effect at Caldwell Community College and Technical Institute since 1973. The first step in the process was the identification of planning areas: administration, organization, educational programs, learning resources, student services, faculty, facilities, maintenance/operation, and finances. The major…

  7. ARC-2006-ACD06-0179-002

    NASA Image and Video Library

    2006-10-12

    Ames holds a Media Day at the Hypervelocity Free Flight facility where Ames is conducting high-speed tests of small models of the agency's new Orion CEV to learn about stability during flight. The hypervelocity test facility uses a gun to shoot Orion models between 0.5 and l.5 inches (1.25 - 3.75 centimeters in diameter. The facility can conduct experiments with speeds up to 19,000 miles per hour (30,400 kilometers per hour) - NBC Channel 11 Technology/Business reporter Scott Budman at the gun range (w/C Acosta in bkgrd)

  8. A Versatile Rocket Engine Hot Gas Facility

    NASA Technical Reports Server (NTRS)

    Green, James M.

    1993-01-01

    The capabilities of a versatile rocket engine facility, located in the Rocket Laboratory at the NASA Lewis Research Center, are presented. The gaseous hydrogen/oxygen facility can be used for thermal shock and hot gas testing of materials and structures as well as rocket propulsion testing. Testing over a wide range of operating conditions in both fuel and oxygen rich regimes can be conducted, with cooled or uncooled test specimens. The size and location of the test cell provide the ability to conduct large amounts of testing in short time periods with rapid turnaround between programs.

  9. Shuttle Laser Technology Experiment Facility (LTEF)-to-airplane lasercom experiment: Airplane considerations

    NASA Technical Reports Server (NTRS)

    Kalil, Ford

    1990-01-01

    NASA is considering the use of various airplanes for a Shuttle Laser Technology Experiment Facility (LTEF)-to-Airplane laser communications experiment. As supporting documentation, pertinent technical details are included about the potential use of airplanes located at Ames Research Center and Wallops Flight Facility. The effects and application of orbital mechanics considerations are also presented, including slant range, azimuth, elevation, and time. The pros and cons of an airplane equipped with a side port with a bubble window versus a top port with a dome are discussed.

  10. Inlet noise on 0.5-meter-diameter NASA QF-1 fan as measured in an unmodified compressor aerodynamic test facility and in an anechoic chamber

    NASA Technical Reports Server (NTRS)

    Gelder, T. F.; Soltis, R. F.

    1975-01-01

    Narrowband analysis revealed grossly similar sound pressure level spectra in each facility. Blade passing frequency (BPF) noise and multiple pure tone (MPT) noise were superimposed on a broadband (BB) base noise. From one-third octave bandwidth sound power analyses the BPF noise (harmonics combined), and the MPT noise (harmonics combined, excepting BPF's) agreed between facilities within 1.5 db or less over the range of speeds and flows tested. Detailed noise and aerodynamic performance is also presented.

  11. The Altitude Wind Tunnel (AWT): A unique facility for propulsion system and adverse weather testing

    NASA Technical Reports Server (NTRS)

    Chamberlin, R.

    1985-01-01

    A need has arisen for a new wind tunnel facility with unique capabilities for testing propulsion systems and for conducting research in adverse weather conditions. New propulsion system concepts, new aircraft configurations with an unprecedented degree of propulsion system/aircraft integration, and requirements for aircraft operation in adverse weather dictate the need for a new test facility. Required capabilities include simulation of both altitude pressure and temperature, large size, full subsonic speed range, propulsion system operation, and weather simulation (i.e., icing, heavy rain). A cost effective rehabilitation of the NASA Lewis Research Center's Altitude Wind Tunnel (AWT) will provide a facility with all these capabilities.

  12. Ambient concentrations of total suspended particulate matter and its elemental constituents at the wider area of the mining facilities of TVX Hellas in Chalkidiki, Greece.

    PubMed

    Gaidajis, George

    2003-01-01

    To assess ambient air quality at the wider area of TVX Hellas mining facilities, the Total Suspended Particulate matter (TSP) and its content in characteristic elements, i.e., As, Cd, Cu, Fe, Mn, Pb, Zn are being monitored for more than thirty months as part of the established Environmental Monitoring Program. High Volume air samplers equipped with Tissue Quartz filters were employed for the collection of TSP. Analyses were effected after digestion of the suspended particulate with an HNO3-HCl solution and determination of elemental concentrations with an Atomic Absorption Spectroscopy equipped with graphite furnace. The sampling stations were selected to record representatively the existing ambient air quality in the vicinity of the facilities and at remote sites not affected from industrial activities. Monitoring data indicated that the background TSP concentrations ranged from 5-60 microg/m3. Recorded TSP concentrations at the residential sites close to the facilities ranged between 20-100 microg/m3, indicating only a minimal influence from the mining and milling activities. Similar spatial variation was observed for the TSP constituents and specifically for Pb and Zn. To validate the monitoring procedures, a parallel sampling campaign took place with different High Volume samplers at days where low TSP concentrations were expected. The satisfactory agreement (+/- 11%) at low concentrations (50-100 microg/m3) clearly supported the reproducibility of the techniques employed specifically at the critical range of lower concentrations.

  13. Research yields precise uncertainty equations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, E.H.; Ferguson, K.R.

    1987-08-03

    Results of a study of orifice-meter accuracy by Chevron Oil Field Research Co. at its Venice, La., calibration facility have important implications for natural gas custody-transfer measurement. The calibration facility, data collection, and equipment calibration were described elsewhere. This article explains the derivation of uncertainty factors and details the study's findings. The results were based on calibration of two 16-in. orifice-meter runs. The experimental data cover a beta-ratio range of from 0.27 to 0.71 and a Reynolds number range of from 4,000,000 to 35,000,000. Discharge coefficients were determined by comparing the orifice flow to the flow from critical-flow nozzles.

  14. Application of space technology to crustal dynamics and earthquake research

    NASA Technical Reports Server (NTRS)

    1979-01-01

    In cooperation with other Federal government agencies, and the governments of other countries, NASA is undertaking a program of research in geodynamics. The present program activities and plans for extension of these activities in the time period 1979-1985 are described. The program includes operation of observatories for laser ranging to the Moon and to artificial satellites, and radio observatories for very long baseline microwave interferometry (VLBI). These observatories are used to measure polar motion, earth rotation, and tectonic plate movement, and serve as base stations for mobile facilities. The mobile laser ranging and VLBI facilities are used to measure crustal deformation in tectonically active areas.

  15. Identity and distribution of residues of energetic compounds at army live-fire training ranges.

    PubMed

    Jenkins, Thomas F; Hewitt, Alan D; Grant, Clarence L; Thiboutot, Sonia; Ampleman, Guy; Walsh, Marianne E; Ranney, Thomas A; Ramsey, Charles A; Palazzo, Antonio J; Pennington, Judith C

    2006-05-01

    Environmental investigations have been conducted at 23 military firing ranges in the United States and Canada. The specific training facilities most frequently evaluated were hand grenade, antitank rocket, and artillery ranges. Energetic compounds (explosives and propellants) were determined and linked to the type of munition used and the major mechanisms of deposition.

  16. Starkey experimental forest and range.

    Treesearch

    Valerie. Rapp

    2004-01-01

    The Starkey Experimental Forest and Range. (Starkey) is a one-of-a-kind, world class research facility, located in the Blue Mountains of northeastern Oregon. Starkey is the primary field location for scientific study of the effects of deer, elk, and cattle on ecosystems. Most of the 28,000-acre forest and range is enclosed by a game-proof fence.The research...

  17. Perceived and insurance-related barriers to the provision of contraceptive services in U.S. abortion care settings.

    PubMed

    Kavanaugh, Megan L; Jones, Rachel K; Finer, Lawrence B

    2011-01-01

    Abortion facilities represent a potentially convenient setting for providing contraception to women experiencing unintended pregnancies. This analysis examines a range of factors that may act as barriers to integrating contraceptive and abortion services and documents abortion providers' perspectives on their role in their patients' contraceptive care. Administrators from 173 large, nonhospital facilities that provide abortions in the United States responded to a structured survey between May and September 2009. We used chi-square tests to assess differences in categorical outcomes. Although the majority of U.S. abortion facilities offer a range of contraceptive methods on site, facility staff identified multiple barriers to full integration of the two services, in particular, insurance, patient, and cost barriers. Few of these perceived barriers, however, were associated with differences in the actual provision of most contraceptive methods. Specialized abortion clinics that do not accept health insurance were less likely to have highly effective methods, such as intrauterine devices and implants, on site. Facilities located in Medicaid states were more likely to accept both public and private health insurance for contraceptive services. Increased access to contraceptive services during abortion care is one strategy for reducing repeat unintended pregnancy, and stakeholders at all levels--including abortion providers, insurance companies, and policy makers--have a role to play in achieving this goal. Copyright © 2011 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  18. The Neutrons for Science Facility at SPIRAL-2

    NASA Astrophysics Data System (ADS)

    Ledoux, X.; Aïche, M.; Avrigeanu, M.; Avrigeanu, V.; Audouin, L.; Balanzat, E.; Ban-détat, B.; Ban, G.; Barreau, G.; Bauge, E.; Bélier, G.; Bem, P.; Blideanu, V.; Borcea, C.; Bouffard, S.; Caillaud, T.; Chatillon, A.; Czajkowski, S.; Dessagne, P.; Doré, D.; Fallot, M.; Farget, F.; Fischer, U.; Giot, L.; Granier, T.; Guillous, S.; Gunsing, F.; Gustavsson, C.; Jacquot, B.; Jansson, K.; Jurado, B.; Kerveno, M.; Klix, A.; Landoas, O.; Lecolley, F. R.; Lecouey, J. L.; Majerle, M.; Marie, N.; Materna, T.; Mrazek, J.; Negoita, F.; Novak, J.; Oberstedt, S.; Oberstedt, A.; Panebianco, S.; Perrot, L.; Plompen, A. J. M.; Pomp, S.; Ramillon, J. M.; Ridikas, D.; Rossé, B.; Rudolf, G.; Serot, O.; Simakov, S. P.; Simeckova, E.; Smith, A. G.; Sublet, J. C.; Taieb, J.; Tassan-Got, L.; Tarrio, D.; Takibayev, A.; Thfoin, I.; Tsekhanovich, I.; Varignon, C.

    2014-05-01

    The Neutrons For Science (NFS) facility is a component of SPIRAL-2 laboratory under construction at Caen (France). SPIRAL-2 is dedicated to the production of high intensity Radioactive Ions Beams (RIB). It is based on a high-power linear accelerator (LINAG) to accelerate deuterons beams in order to produce neutrons by breakup reactions on a C converter. These neutrons will induce fission in 238U for production of radioactive isotopes. Additionally to the RIB production, the proton and deuteron beams delivered by the accelerator will be used in the NFS facility. NFS is composed of a pulsed neutron beam and irradiation stations for cross-section measurements and material studies. The beams delivered by the LINAG will allow producing intense neutron beams in the 100 keV-40 MeV energy range with either a continuous or quasi-mono-energetic spectrum. At NFS available average fluxes will be up to 2 orders of magnitude higher than those of other existing time-of-flight facilities in the 1 MeV - 40 MeV range. NFS will be a very powerful tool for fundamental physics and application related research in support of the transmutation of nuclear waste, design of future fission and fusion reactors, nuclear medicine or test and development of new detectors. The facility and its characteristics are described, and several examples of the first potential experiments are presented.

  19. Low Earth orbital atomic oxygen environmental simulation facility for space materials evaluation

    NASA Technical Reports Server (NTRS)

    Stidham, Curtis R.; Banks, Bruce A.; Stueber, Thomas J.; Dever, Joyce A.; Rutledge, Sharon K.; Bruckner, Eric J.

    1993-01-01

    Simulation of low Earth orbit atomic oxygen for accelerated exposure in ground-based facilities is necessary for the durability evaluation of space power system component materials for Space Station Freedom (SSF) and future missions. A facility developed at the National Aeronautics and Space Administrations's (NASA) Lewis Research Center provides accelerated rates of exposure to a directed or scattered oxygen beam, vacuum ultraviolet (VUV) radiation, and offers in-situ optical characterization. The facility utilizes an electron-cyclotron resonance (ECR) plasma source to generate a low energy oxygen beam. Total hemispherical spectral reflectance of samples can be measured in situ over the wavelength range of 250 to 2500 nm. Deuterium lamps provide VUV radiation intensity levels in the 115 to 200 nm range of three to five equivalent suns. Retarding potential analyses show distributed ion energies below 30 electron volts (eV) for the operating conditions most suited for high flux, low energy testing. Peak ion energies are below the sputter threshold energy (approximately 30 eV) of the protective coatings on polymers that are evaluated in the facility, thus allowing long duration exposure without sputter erosion. Neutral species are expected to be at thermal energies of approximately .04 eV to .1 eV. The maximum effective flux level based on polyimide Kapton mass loss is 4.4 x 10 exp 6 atoms/((sq. cm)*s), thus providing a highly accelerated testing capability.

  20. Evaluation of hydrocarbon flow standard facility equipped with double-wing diverter using four types of working liquids

    NASA Astrophysics Data System (ADS)

    Doihara, R.; Shimada, T.; Cheong, K. H.; Terao, Y.

    2017-06-01

    A flow calibration facility based on the gravimetric method using a double-wing diverter for hydrocarbon flows from 0.1 m3 h-1 to 15 m3 h-1 was constructed as a national measurement standard in Japan. The original working liquids were kerosene and light oil. The calibration facility was modified to calibrate flowmeters with two additional working liquids, industrial gasoline (flash point  >  40 °C) and spindle oil, to achieve calibration over a wide viscosity range at the same calibration test rig. The kinematic viscosity range is 1.2 mm2 s-1 to 24 mm2 s-1. The contributions to the measurement uncertainty due to different types of working liquids were evaluated experimentally in this study. The evaporation error was reduced by using a seal system at the weighing tank inlet. The uncertainty due to droplets from the diverter wings was reduced by a modified diverter operation. The diverter timing errors for all types of working liquids were estimated. The expanded uncertainties for the calibration facility were estimated to be 0.020% for mass flow and 0.030% for volumetric flow for all considered types of liquids. Internal comparisons with other calibration facilities were also conducted, and the agreement was confirmed to be within the claimed expanded uncertainties.

  1. 21 CFR 803.33 - If I am a user facility, what must I include when I submit an annual report?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES MEDICAL DEVICE REPORTING User Facility... medical device reports, or the number assigned by us for reporting purposes in accordance with § 803.3; (2...) Date of the annual report and report numbers identifying the range of medical device reports that you...

  2. 21 CFR 803.33 - If I am a user facility, what must I include when I submit an annual report?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES MEDICAL DEVICE REPORTING User Facility... medical device reports, or the number assigned by us for reporting purposes in accordance with § 803.3; (2...) Date of the annual report and report numbers identifying the range of medical device reports that you...

  3. FME Carpentry Shop Keeps Facility in Good Repair | Poster

    Cancer.gov

    By Peggy Pearl, Contributing Writer Did you know that what most people call the Carpentry Shop at Facilities Maintenance and Engineering (FME) is actually made up of the three crafts, woodcrafting, painting, and locksmithing?  On any given day, throughout the Frederick National Laboratory campus, you may find shop staff utilizing an assortment of tools and a wide range of

  4. Knowledge-based image data management - An expert front-end for the BROWSE facility

    NASA Technical Reports Server (NTRS)

    Stoms, David M.; Star, Jeffrey L.; Estes, John E.

    1988-01-01

    An intelligent user interface being added to the NASA-sponsored BROWSE testbed facility is described. BROWSE is a prototype system designed to explore issues involved in locating image data in distributed archives and displaying low-resolution versions of that imagery at a local terminal. For prototyping, the initial application is the remote sensing of forest and range land.

  5. An Overview of National Transonic Facility Investigations for High Performance Military Aerodynamics (Invited)

    NASA Technical Reports Server (NTRS)

    Luckring, J. M.

    2001-01-01

    A review of National Transonic Facility (NTF) investigations for high-performance military aerodynamics has been completed. The review spans the entire operational period of the tunnel, and includes configurations ranging from full aircraft to basic research geometries. The intent for this document is to establish a comprehensive summary of these experiments with selected technical results

  6. The use of an automated flight test management system in the development of a rapid-prototyping flight research facility

    NASA Technical Reports Server (NTRS)

    Duke, Eugene L.; Hewett, Marle D.; Brumbaugh, Randal W.; Tartt, David M.; Antoniewicz, Robert F.; Agarwal, Arvind K.

    1988-01-01

    An automated flight test management system (ATMS) and its use to develop a rapid-prototyping flight research facility for artificial intelligence (AI) based flight systems concepts are described. The ATMS provides a flight test engineer with a set of tools that assist in flight planning and simulation. This system will be capable of controlling an aircraft during the flight test by performing closed-loop guidance functions, range management, and maneuver-quality monitoring. The rapid-prototyping flight research facility is being developed at the Dryden Flight Research Facility of the NASA Ames Research Center (Ames-Dryden) to provide early flight assessment of emerging AI technology. The facility is being developed as one element of the aircraft automation program which focuses on the qualification and validation of embedded real-time AI-based systems.

  7. Advances in Engine Test Capabilities at the NASA Glenn Research Center's Propulsion Systems Laboratory

    NASA Technical Reports Server (NTRS)

    Pachlhofer, Peter M.; Panek, Joseph W.; Dicki, Dennis J.; Piendl, Barry R.; Lizanich, Paul J.; Klann, Gary A.

    2006-01-01

    The Propulsion Systems Laboratory at the National Aeronautics and Space Administration (NASA) Glenn Research Center is one of the premier U.S. facilities for research on advanced aeropropulsion systems. The facility can simulate a wide range of altitude and Mach number conditions while supplying the aeropropulsion system with all the support services necessary to operate at those conditions. Test data are recorded on a combination of steady-state and highspeed data-acquisition systems. Recently a number of upgrades were made to the facility to meet demanding new requirements for the latest aeropropulsion concepts and to improve operational efficiency. Improvements were made to data-acquisition systems, facility and engine-control systems, test-condition simulation systems, video capture and display capabilities, and personnel training procedures. This paper discusses the facility s capabilities, recent upgrades, and planned future improvements.

  8. Man-Vehicle Systems Research Facility - Design and operating characteristics

    NASA Technical Reports Server (NTRS)

    Shiner, Robert J.; Sullivan, Barry T.

    1992-01-01

    This paper describes the full-mission flight simulation facility at the NASA Ames Research Center. The Man-Vehicle Systems Research Facility (MVSRF) supports aeronautical human factors research and consists of two full-mission flight simulators and an air-traffic-control simulator. The facility is used for a broad range of human factors research in both conventional and advanced aviation systems. The objectives of the research are to improve the understanding of the causes and effects of human errors in aviation operations, and to limit their occurrence. The facility is used to: (1) develop fundamental analytical expressions of the functional performance characteristics of aircraft flight crews; (2) formulate principles and design criteria for aviation environments; (3) evaluate the integration of subsystems in contemporary flight and air traffic control scenarios; and (4) develop training and simulation technologies.

  9. Trace-element characterization of evidential cannabis sative samples using k{sub 0}-standardization methodology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henderson, D.P. Jr.; Vernetson, W.G.; Ratner, R.T.

    The University of Florida Training Reactor (UFTR) facilities including the analytical laboratory are used for a wide range of educational, research, training, and service functions. The UFTR is a 100-kW light-water-cooled, graphite-and-water-moderated modified Argonaut-type reactor. The UFTR utilizes high enriched plate-type fuel in a two-slab arrangement and operates at a 100-kW power level. Since first licensed to operate at 10 kW in 1959, this nonpower reactor facility has had an active but evolving record of continuous service to a wide range of academic, utility, and community users. The services of the UFTR have also been used by various state authoritiesmore » in criminal investigations. Because of its relatively low power and careful laboratory analyses, the UFTR neutron flux characteristics in several ports are not only well characterized but they are also quite invariant with time. As a result, such a facility is well-suited to the application of the multielement analysis using the k{sub o}-standardization method of neutron activation analysis. The analysis of untreated evidential botanical samples presented a unique opportunity to demonstrate implementation of this method at the UFTR facilities.« less

  10. Project Nuclotron-based Ion Collider fAcility at JINR

    NASA Astrophysics Data System (ADS)

    Kekelidze, V. D.; Matveev, V. A.; Meshkov, I. N.; Sorin, A. S.; Trubnikov, G. V.

    2017-09-01

    The project of Nuclotron-based Ion Collider fAcility (NICA) that is under development at JINR (Dubna) is presented. The general goals of the project are experimental studies of both hot and dense baryonic matter and spin physics (in collisions of polarized protons and deuterons). The first program requires providing of heavy ion collisions in the energy range of √ {{s_{NN}}} = 4-11 Gev at average luminosity of L = 1 × 1027 cm-2 s-1 for 197Au79+ nuclei. The polarized beams mode is proposed to be used in energy range of √ {{s_{NN}}} = 12-27 Gev (protons at luminosity of L ≥ 1 × 1030 cm-2 s-1. The report contains description of the facility scheme and its characteristics in heavy ion operation mode. The Collider will be equipped with two detectors—MultiPurpose Detector (MPD), which is in an active stage of construction, and Spin Physics Detector (SPD) that is in the stage of conceptual design. Fixed target experiment "Baryonic matter at Nuclotron" (BM@N) will be performed in very beginning of the project. The wide program of applied researches at NICA facility is being developed as well.

  11. Lessons learned from surface wipe sampling for lead in three workplaces.

    PubMed

    Beaucham, Catherine; Ceballos, Diana; King, Bradley

    2017-08-01

    Surface wipe sampling in the occupational environment is a technique widely used by industrial hygienists. Although several organizations have promulgated standards for sampling lead and other metals, uncertainty still exists when trying to determine an appropriate wipe sampling strategy and how to interpret sampling results. Investigators from the National Institute for Occupational Safety and Health (NIOSH) Health Hazard Evaluation Program have used surface wipe sampling as part of their exposure assessment sampling strategies in a wide range of workplaces. This article discusses wipe sampling for measuring lead on surfaces in three facilities: (1) a battery recycling facility; (2) a firing range and gun store; and (3) an electronic scrap recycling facility. We summarize our findings from the facilities and what we learned by integrating wipe sampling into our sampling plan. Wiping sampling demonstrated lead in non-production surfaces in all three workplaces and that the potential that employees were taking lead home to their families existed. We also found that the presence of metals such as tin can interfere with the colorimetric results. We also discuss the advantages and disadvantages of colorimetric analysis of surface wipe samples and the challenges we faced when interpreting wipe sampling results.

  12. Large aperture wide field multi-object spectroscopy for the 2020s: the science and status of the Maunakea Spectroscopic Explorer.

    NASA Astrophysics Data System (ADS)

    Devost, Daniel; McConnachie, Alan; Chambers, Kenneth; Gallagher, Sarah; Maunakea Spectroscopic Explorer Project office, MSE Science Advisory group, MSE Science Team

    2018-01-01

    Numerous international reports have recently highlighted the need for fully dedicated, large aperture, highly multiplexed spectroscopy at a range of spectral resolutions in the OIR wavelength range. Such a facility is the most obvious missing link in the emerging network of international multi-wavelength, astronomy facilities, and enables science from reverberation mapping of black holes to the nucleosynthetic history of the Galaxy, and will follow-up discoveries from the optical through to the radio with facilities such as LSST. The only fully dedicated large aperture MOS facility that is in the design phase is the Maunakea Spectroscopic Explorer (MSE), an 11.4m segmented mirror prime focus telescope with a 1.5 square degree field of view that has 3200 fibers at low (R~2500) and moderate (R~6000) resolution, and 1000 fibers at high (R=20/40000) resolution. I will provide an overview of MSE, describing the science drivers and the current design status, as well as the international partnership, and the results of multiple, newly completed, external reviews for the system and subsystems. The anticipated cost and timeline to first light will also be presented.

  13. Does identity shape leadership and management practice? Experiences of PHC facility managers in Cape Town, South Africa

    PubMed Central

    Daire, Judith; Gilson, Lucy

    2014-01-01

    In South Africa, as elsewhere, Primary Health Care (PHC) facilities are managed by professional nurses. Little is known about the dimensions and challenges of their job, or what influences their managerial practice. Drawing on leadership and organizational theory, this study explored what the job of being a PHC manager entails, and what factors influence their managerial practice. We specifically considered whether the appointment of professional nurses as facility managers leads to an identity transition, from nurse to manager. The overall intention was to generate ideas about how to support leadership development among PHC facility managers. Adopting case study methodology, the primary researcher facilitated in-depth discussions (about their personal history and managerial experiences) with eight participating facility managers from one geographical area. Other data were collected through in-depth interviews with key informants, document review and researcher field notes/journaling. Analysis involved data triangulation, respondent and peer review and cross-case analysis. The experiences show that the PHC facility manager’s job is dominated by a range of tasks and procedures focused on clinical service management, but is expected to encompass action to address the population and public health needs of the surrounding community. Managing with and through others, and in a complex system, requiring self-management, are critical aspects of the job. A range of personal, professional and contextual factors influence managerial practice, including professional identity. The current largely facility-focused management practice reflects the strong nursing identity of managers and broader organizational influences. However, three of the eight managers appear to self-identify an emerging leadership identity and demonstrate related managerial practices. Nonetheless, there is currently limited support for an identity transition towards leadership in this context. Better support for leadership development could include talent-spotting and nurturing, induction and peer-mentoring for newly appointed facility managers, ongoing peer-support once in post and continuous reflective practice. PMID:25274644

  14. Variation in Management of Patients With Obstructive Coronary Artery Disease: Insights From the Veterans Affairs Clinical Assessment and Reporting Tool (VA CART) Program.

    PubMed

    Sandhu, Amneet; Stanislawski, Maggie A; Grunwald, Gary K; Guinn, Kathryn; Valle, Javier; Matlock, Daniel; Ho, P Michael; Maddox, Thomas M; Bradley, Steven M

    2017-09-12

    Little is known about facility-level variation in the use of revascularization procedures for the management of stable obstructive coronary artery disease. Furthermore, it is unknown if variation in the use of coronary revascularization is associated with use of other cardiovascular procedures. We evaluated all elective coronary angiograms performed in the Veterans Affairs system between September 1, 2007, and December 31, 2011, using the Clinical Assessment and Reporting Tool and identified patients with obstructive coronary artery disease. Patients were considered managed with revascularization if they received percutaneous coronary intervention (PCI) or coronary artery bypass grafting within 30 days of diagnosis. We calculated risk-adjusted facility-level rates of overall revascularization, PCI, and coronary artery bypass grafting. In addition, we determined the association between facility-level rates of revascularization and post-PCI stress testing. Among 15 650 patients at 51 Veterans Affairs sites who met inclusion criteria, the median rate of revascularization was 59.6% (interquartile range, 55.7%-66.7%). Across all facilities, risk-adjusted rates of overall revascularization varied from 41.5% to 88.1%, rate of PCI varied from 23.2% to 80.6%, and rate of coronary artery bypass graftingvariedfrom 7.5% to 36.5%. Of 6179 patients who underwent elective PCI, the median rate of stress testing in the 2 years after PCI was 33.7% (interquartile range, 30.7%-47.1%). There was no evidence of correlation between facility-level rate of revascularization and follow-up stress testing. Within the Veterans Affairs system, we observed large facility-level variation in rates of revascularization for obstructive coronary artery disease, with variation driven primarily by PCI. There was no association between facility-level use of revascularization and follow-up stress testing, suggesting use rates are specific to a particular procedure and not a marker of overall facility-level use. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  15. Evaluation of beam wobbling methods for heavy-ion radiotherapy.

    PubMed

    Yonai, Shunsuke; Kanematsu, Nobuyuki; Komori, Masataka; Kanai, Tatsuaki; Takei, Yuka; Takahashi, Osamu; Isobe, Yoshiharu; Tashiro, Mutsumi; Koikegami, Hajime; Tomita, Hideki

    2008-03-01

    The National Institute of Radiological Sciences (NIRS) has extensively studied carbon-ion radiotherapy at the Heavy-Ion Medical Accelerator in Chiba (HIMAC) with some positive outcomes, and has established its efficacy. Therefore, efforts to distribute the therapy to the general public should be made, for which it is essential to enable direct application of clinical and technological experiences obtained at NIRS. For widespread use, it is very important to reduce the cost through facility downsizing with minimal acceleration energy to deliver the HIMAC-equivalent clinical beams. For the beam delivery system, the requirement of miniaturization is translated to reduction in length while maintaining the clinically available field size and penetration range for range-modulated uniform broad beams of regular fields that are either circular or square for simplicity. In this paper, we evaluate the various wobbling methods including original improvements, especially for application to the compact facilities through the experimental and computational studies. The single-ring wobbling method used at HIMAC is the best one including a lot of experience at HIMAC but the residual range is a fatal problem in the case of a compact facility. On the other hand, uniform wobbling methods such as the spiral and zigzag wobbling methods are effective and suitable for a compact facility. Furthermore, these methods can be applied for treatment with passive range modulation including respiratory gated irradiation. In theory, the choice between the spiral and zigzag wobbling methods depends on the shape of the required irradiation field. However, we found that it is better to use the zigzag wobbling method with transformation of the wobbling pattern even when a circular uniform irradiation field is required, because it is difficult to maintain the stability of the wobbler magnet due to the rapid change of the wobbler current in the spiral wobbling method. The regulated wobbling method, which is our improvement, can well expand the uniform irradiation field and lead to reducing the power requirement of the wobbler magnets. Our evaluations showed that the regulated zigzag wobbling method is the most suitable method for use in currently designed compact carbon-therapy facilities.

  16. Marshall Space Flight Center's Impact Testing Facility Capabilities

    NASA Technical Reports Server (NTRS)

    Evans, Steve; Finchum, Andy; Hubbs, Whitney; Gray, Perry

    2008-01-01

    Marshall Space Flight Center's (MSFC) Impact Testing Facility (ITF) serves as an important installation for space and missile related materials science research. The ITF was established and began its research in spacecraft debris shielding in the early 1960s, then played a major role in the International Space Station debris shield development. As NASA became more interested in launch debris and in-flight impact concerns, the ITF grew to include research in a variety of impact genres. Collaborative partnerships with the DoD led to a wider range of impact capabilities being relocated to MSFC as a result of the closure of Particle Impact Facilities in Santa Barbara, California, The Particle Impact Facility had a 30 year history in providing evaluations of aerospace materials and components during flights through rain, ice, and solid particle environments at subsonic through hypersonic velocities. The facility's unique capabilities were deemed a 'National Asset' by the DoD, The ITF now has capabilities including environmental, ballistic, and hypervelocity impact testing utilizing an array of air, powder, and two-stage light gas guns to accommodate a variety of projectile and target types and sizes. Relocated test equipment was dated and in need of upgrade. Numerous upgrades including new instrumentation, triggering circuitry, high speed photography, and optimized sabot designs have been implemented. Other recent research has included rain drop demise characterization tests to obtain data for inclusion in on-going model development. Future ITF improvements will be focused on continued instrumentation and performance enhancements. These enhancements will allow further, more in-depth, characterization of rain drop demise characterization and evaluation of ice crystal impact. Performance enhancements also include increasing the upper velocity limit of the current environmental guns to allow direct environmental simulation for missile components. The current and proposed ITF capabilities range from rain to micrometeoroids allowing the widest test parameter range possible for materials investigations in support of space, atmospheric, and ground environments. These test capabilities including hydrometeor, single/multi-particle, ballistic gas guns, exploding wire gun, and light gas guns combined with Smooth Particle Hydrodynamics Code (SPHC) simulations represent the widest range of impact test capabilities in the country.

  17. Marshall Space Flight Center's Impact Testing Facility Capabilities

    NASA Technical Reports Server (NTRS)

    Evans, Steve; Finchum, Andy; Hubbs, Whitney

    2008-01-01

    Marshall Space Flight Center's (MSFC) Impact Testing Facility (ITF) serves as an important installation for space and missile related materials science research. The ITF was established and began its research in spacecraft debris shielding in the early 1960% then played a major role in the International Space Station debris shield development. As NASA became more interested in launch debris and in-flight impact concerns, the ITF grew to include research in a variety of impact genres. Collaborative partnerships with the DoD led to a wider range of impact capabilities being relocated to MSFC as a result of the closure of Particle Impact Facilities in Santa Barbara, California. The Particle Impact Facility had a 30 year history in providing evaluations of aerospace materials and components during flights through rain, ice, and solid particle environments at subsonic through hypersonic velocities. The facility's unique capabilities were deemed a "National Asset" by the DoD. The ITF now has capabilities including environmental, ballistic, and hypervelocity impact testing utilizing an array of air, powder, and two-stage light gas guns to accommodate a variety of projectile and target types and sizes. Relocated test equipment was dated and in need of upgrade. Numerous upgrades including new instrumentation, triggering circuitry, high speed photography, and optimized sabot designs have been implemented. Other recent research has included rain drop demise characterization tests to obtain data for inclusion in on-going model development. Future ITF improvements will be focused on continued instrumentation and performance enhancements. These enhancements will allow further, more in-depth, characterization of rain drop demise characterization and evaluation of ice crystal impact. Performance enhancements also include increasing the upper velocity limit of the current environmental guns to allow direct environmental simulation for missile components. The current and proposed ITF capabilities range from rain to micrometeoroids allowing the widest test parameter range possible for materials investigations in support of space, atmospheric, and ground environments. These test capabilities including hydrometeor, single/multi-particle, ballistic gas grins, exploding wire gun, and light gas guns combined with Smooth Particle Hydrodynamics Code (SPHC) simulations represent the widest range of impact test capabilities in the country.

  18. Monitoring the performances of a real scale municipal solid waste composting and a biodrying facility using respiration activity indices.

    PubMed

    Evangelou, Alexandros; Gerassimidou, Spyridoula; Mavrakis, Nikitas; Komilis, Dimitrios

    2016-05-01

    Objective of the work was to monitor two full-scale commingled municipal solid waste (MSW) mechanical and biological pretreatment (MBT) facilities in Greece, namely a biodrying and a composting facility. Monitoring data from a 1.5-year sampling period is presented, whilst microbial respiration indices were used to monitor the decomposition process and the stability status of the wastes in both facilities during the process. Results showed that in the composting facility, the organic matter reduced by 35 % after 8 weeks of combined composting/curing. Material exiting the biocells had a moisture content of less than 30 % (wb) indicating a moisture limitation during the active composting process. The static respiration indexes indicated that some stabilization occurred during the process, but the final material could not be characterized as stable compost. In the biodrying facility, the initial and final moisture contents were 50 % and less than 20 % wb, respectively, and the biodrying index was equal to 4.1 indicating effective biodrying. Lower heating values at the inlet and outlet were approximately 5.5 and 10 MJ/wet kg, respectively. The organic matter was reduced by 20 % during the process and specifically from a range of 63-77 % dw (inlet) to a range of 61-70 % dw. A significant respiration activity reduction was observed for some of the biodrying samples. A statistically significant correlation among all three respiration activity indices was recorded, with the two oxygen related activity indices (CRI7 and SRI24) observing the highest correlation.

  19. Containerless Processing in Reduced Gravity Using the TEMPUS Facility during MSL-1 and MSL-1R

    NASA Technical Reports Server (NTRS)

    Rogers, Jan R.

    1998-01-01

    Containerless processing provides a high purity environment for the study of high-temperature, very reactive materials. It is an important method which provides access to the metastable state of an undercooled melt. In the absence of container walls, the nucleation rate is greatly reduced and undercooling up to (Tm-Tn)/Tm approx. equal to 0.2 can be obtained, where Tm and Tn are the melting and nucleation temperatures, respectively. Electromagnetic levitation represents a method particularly well-suited for the study of metallic melts. The TEMPUS (Tiegelfreies ElektroMagnetisches Prozessieren Unter Schwerelosgkeit) facility is a research instrument designed to perform electromagnetic levitation studies in reduced gravity. TEMPUS is a joint undertaking between DARA, the German Space Agency, and the Microgravity Science and Applications Division of NASA. The George C. Marshall Space Flight Center provides the leadership for scientific and management efforts which support the four US PI teams which performed experiments in the TEMPUS facility. The facility is sensitive to accelerations in the 1-10 Hz range. This became evident during the MSL-1 mission. Analysis of accelerometer and video data indicated that loss of sample control occurred during crew exercise periods which created disturbances in this frequency range. Prior to the MSL-1R flight the TEMPUS team, the accelerometer support groups and the mission operations team developed a strategy to provide for the operation of the facility without such disturbances. The successful implementation of this plan led to the highly successful operation of this facility during MSL-1R.

  20. Development of a Quasi-monoenergetic 6 MeV Gamma Facility at NASA Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Nowicki, Suzanne F.; Hunter, Stanley D.; Parsons, Ann M.

    2012-01-01

    The 6 MeV Gamma Facility has been developed at NASA Goddard Space Flight Center (GSFC) to allow in-house characterization and testing of a wide range of gamma-ray instruments such as pixelated CdZnTe detectors for planetary science and Compton and pair-production imaging telescopes for astrophysics. The 6 MeV Gamma Facility utilizes a circulating flow of water irradiated by 14 MeV neutrons to produce gamma rays via neutron capture on oxygen (O-16(n,p)N-16 yields O-16* yields O-16 + gamma). The facility provides a low cost, in-house source of 2.742, 6.129 and 7.117 MeV gamma rays, near the lower energy range of most accelerators and well above the 2.614 MeV line from the Th-228 decay chain, the highest energy gamma ray available from a natural radionuclide. The 7.13 s half-life of the N-16 decay allows the water to be irradiated on one side of a large granite block and pumped to the opposite side to decay. Separating the irradiation and decay regions allows for shielding material, the granite block, to be placed between them, thus reducing the low-energy gamma-ray continuum. Comparison between high purity germanium (HPGe) spectra from the facility and a manufactured source, Pu-238/C-13, shows that the low-energy continuum from the facility is reduced by a factor approx. 30 and the gamma-ray rate is approx.100 times higher at 6.129 MeV.

  1. Planetary and Space Simulation Facilities PSI at DLR for Astrobiology

    NASA Astrophysics Data System (ADS)

    Rabbow, E.; Rettberg, P.; Panitz, C.; Reitz, G.

    2008-09-01

    Ground based experiments, conducted in the controlled planetary and space environment simulation facilities PSI at DLR, are used to investigate astrobiological questions and to complement the corresponding experiments in LEO, for example on free flying satellites or on space exposure platforms on the ISS. In-orbit exposure facilities can only accommodate a limited number of experiments for exposure to space parameters like high vacuum, intense radiation of galactic and solar origin and microgravity, sometimes also technically adapted to simulate extraterrestrial planetary conditions like those on Mars. Ground based experiments in carefully equipped and monitored simulation facilities allow the investigation of the effects of simulated single environmental parameters and selected combinations on a much wider variety of samples. In PSI at DLR, international science consortia performed astrobiological investigations and space experiment preparations, exposing organic compounds and a wide range of microorganisms, reaching from bacterial spores to complex microbial communities, lichens and even animals like tardigrades to simulated planetary or space environment parameters in pursuit of exobiological questions on the resistance to extreme environments and the origin and distribution of life. The Planetary and Space Simulation Facilities PSI of the Institute of Aerospace Medicine at DLR in Köln, Germany, providing high vacuum of controlled residual composition, ionizing radiation of a X-ray tube, polychromatic UV radiation in the range of 170-400 nm, VIS and IR or individual monochromatic UV wavelengths, and temperature regulation from -20°C to +80°C at the sample size individually or in selected combinations in 9 modular facilities of varying sizes are presented with selected experiments performed within.

  2. Scaling laws between population and facility densities.

    PubMed

    Um, Jaegon; Son, Seung-Woo; Lee, Sung-Ik; Jeong, Hawoong; Kim, Beom Jun

    2009-08-25

    When a new facility like a grocery store, a school, or a fire station is planned, its location should ideally be determined by the necessities of people who live nearby. Empirically, it has been found that there exists a positive correlation between facility and population densities. In the present work, we investigate the ideal relation between the population and the facility densities within the framework of an economic mechanism governing microdynamics. In previous studies based on the global optimization of facility positions in minimizing the overall travel distance between people and facilities, it was shown that the density of facility D and that of population rho should follow a simple power law D approximately rho(2/3). In our empirical analysis, on the other hand, the power-law exponent alpha in D approximately rho(alpha) is not a fixed value but spreads in a broad range depending on facility types. To explain this discrepancy in alpha, we propose a model based on economic mechanisms that mimic the competitive balance between the profit of the facilities and the social opportunity cost for populations. Through our simple, microscopically driven model, we show that commercial facilities driven by the profit of the facilities have alpha = 1, whereas public facilities driven by the social opportunity cost have alpha = 2/3. We simulate this model to find the optimal positions of facilities on a real U.S. map and show that the results are consistent with the empirical data.

  3. Orbital Debris Assesment Tesing in the AEDC Range G

    NASA Technical Reports Server (NTRS)

    Polk, Marshall; Woods, David; Roebuck, Brian; Opiela, John; Sheaffer, Patti; Liou, J.-C.

    2015-01-01

    The space environment presents many hazards for satellites and spacecraft. One of the major hazards is hypervelocity impacts from uncontrolled man-made space debris. Arnold Engineering Development Complex (AEDC), The National Aeronautics and Space Administration (NASA), The United States Air Force Space and Missile Systems Center (SMC), the University of Florida, and The Aerospace Corporation configured a large ballistic range to perform a series of hypervelocity destructive impact tests in order to better understand the effects of space collisions. The test utilized AEDC's Range G light gas launcher, which is capable of firing projectiles up to 7 km/s. A non-functional full-scale representation of a modern satellite called the DebriSat was destroyed in the enclosed range enviroment. Several modifications to the range facility were made to ensure quality data was obtained from the impact events. The facility modifcations were intended to provide a high impact energy to target mass ratio (>200 J/g), a non-damaging method of debris collection, and an instrumentation suite capable of providing information on the physics of the entire imapct event.

  4. Overview of the NASA Wallops Flight Facility Mobile Range Control System

    NASA Technical Reports Server (NTRS)

    Davis, Rodney A.; Semancik, Susan K.; Smith, Donna C.; Stancil, Robert K.

    1999-01-01

    The NASA GSFC's Wallops Flight Facility (WFF) Mobile Range Control System (MRCS) is based on the functionality of the WFF Range Control Center at Wallops Island, Virginia. The MRCS provides real time instantaneous impact predictions, real time flight performance data, and other critical information needed by mission and range safety personnel in support of range operations at remote launch sites. The MRCS integrates a PC telemetry processing system (TELPro), a PC radar processing system (PCDQS), multiple Silicon Graphics display workstations (IRIS), and communication links within a mobile van for worldwide support of orbital, suborbital, and aircraft missions. This paper describes the MRCS configuration; the TELPro's capability to provide single/dual telemetry tracking and vehicle state data processing; the PCDQS' capability to provide real time positional data and instantaneous impact prediction for up to 8 data sources; and the IRIS' user interface for setup/display options. With portability, PC-based data processing, high resolution graphics, and flexible multiple source support, the MRCS system is proving to be responsive to the ever-changing needs of a variety of increasingly complex missions.

  5. Space radiation studies at the White Sands Missile Range Fast Burst Reactor

    NASA Technical Reports Server (NTRS)

    Delapaz, A.

    1972-01-01

    The operation of the White Sands Missile Range Fast Burst Reactor is discussed. Space radiation studies in radiobiology, dosimetry, and transient radiation effects on electronic systems and components are described. Proposed modifications to increase the capability of the facility are discussed.

  6. Beam-Dynamics Analysis of Long-Range Wakefield Effects on the SCRF Cavities at the Fast Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shin, Young-Min; Bishofberger, Kip; Carlsten, Bruce

    Long-range wakefields in superconducting RF (SCRF) cavities create complicated effects on beam dynamics in SCRF-based FEL beamlines. The driving bunch excites effectively an infinite number of structure modes (including HOMs) which oscillate within the SCRF cavity. Couplers with loads are used to damp the HOMs. However, these HOMs can persist for long periods of time in superconducting structures, which leads to long-range wakefields. Clear understanding of the long-range wakefield effects is a critical element for risk mitigation of future SCRF accelerators such as XFEL at DESY, LCLS-II XFEL, and MaRIE XFEL. We are currently developing numerical tools for simulating long-rangemore » wakefields in SCRF accelerators and plan to experimentally verify the tools by measuring these wakefields at the Fermilab Accelerator Science and Technology (FAST) facility. This paper previews the experimental conditions at the FAST 50 MeV beamline based on the simulation results.« less

  7. A survey of veterinary radiation facilities in 2010.

    PubMed

    Farrelly, John; McEntee, Margaret C

    2014-01-01

    A survey of veterinary radiation therapy facilities in the United States, Canada, and Europe was done in 2010, using an online survey tool, to determine the type of equipment available, radiation protocols used, caseload, tumor types irradiated, as well as other details of the practice of veterinary radiation oncology. The results of this survey were compared to a similar survey performed in 2001. A total of 76 facilities were identified including 24 (32%) academic institutions and 52 (68%) private practice external beam radiation therapy facilities. The overall response rate was 51% (39/76 responded). Based on this survey, there is substantial variation among facilities in all aspects ranging from equipment and personnel to radiation protocols and caseloads. American College of Veterinary Radiology boarded radiation oncologists direct 90% of the radiation facilities, which was increased slightly compared to 2001. All facilities surveyed in 2010 had a linear accelerator. More facilities reported having electron capability (79%) compared to the 2001 survey. Eight facilities had a radiation oncology resident, and academic facilities were more likely to have residents. Patient caseload information was available from 28 sites (37% of radiation facilities), and based on the responses 1376 dogs and 352 cats were irradiated in 2010. The most frequently irradiated tumors were soft tissue sarcomas in dogs, and oral squamous cell carcinoma in cats. © 2014 American College of Veterinary Radiology.

  8. Effect of spa physiotherapy on the range of motion and muscle strength in women with gonarthrosis.

    PubMed

    Lizis, Paweł

    2013-01-01

    Degeneration arthritis is a chronic disease of undetermined progressiveness and unknown pathogenesis. It can affect one or more joints. It reveals itself most frequently between 40 - 60 years of age, and affects the lives of professionally active individuals. The aim of the presented study was to assess the impact of a 21-day stay at a rehabilitation facility on the range of motion and muscle strength of the knee in women with gonarthrosis. The study group consisted of 30 women aged 50-74 years diagnosed with degeneration of the knee joint. The average age of the study group was 65.9 ± 7.2 years. Patients remained in the 21-day rehabilitation facility of Rehabilitational Hospital No. 21 in Busko Zdrój SP ZOZ, Poland. We measured with the help of protractor in SFTR range the motion bending and straightening of the knee with an accuracy of 1°. The Lovett strength test was assessed of the ischio-tibial muscles, quadriceps, sartorius--acting on the knee joint of the patient. The study was carried out on the first and the last day of the stay in the rehabilitation facility. There was improvement in the range of flexion and strength of muscles acting on the knee joint of the afflicted women. The study showed that 21-day rehabilitation holiday improved the range and strength of the muscles acting on the knee joint of the afflicted women. This proved that comprehensive rehabilitation improves the function of the knee joint with gonarthrosis, prevents disease progression and is an alternative to drug therapy.

  9. LH2 airport requirements study

    NASA Technical Reports Server (NTRS)

    Brewer, G. D. (Editor)

    1976-01-01

    A preliminary assessment of the facilities and equipment which will be required at a representative airport is provided so liquid hydrogen LH2 can be used as fuel in long range transport aircraft in 1995-2000. A complete facility was conceptually designed, sized to meet the projected air traffic requirement. The facility includes the liquefaction plant, LH2, storage capability, and LH2 fuel handling system. The requirements for ground support and maintenance for the LH2 fueled aircraft were analyzed. An estimate was made of capital and operating costs which might be expected for the facility. Recommendations were made for design modifications to the reference aircraft, reflecting results of the analysis of airport fuel handling requirements, and for a program of additional technology development for air terminal related items.

  10. Site Environmental Report for Calendar Year 2005. DOE Operations at The Boeing Company, Santa Susana Field Laboratory, Area IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2006-09-30

    This annual report describes the environmental monitoring programs related to the Department of Energy’s (DOE) activities at the Santa Susana Field Laboratory (SSFL) facility located in Ventura County, California during 2005. Part of the SSFL facility, known as Area IV, had been used for DOE’s activities since the 1950s. A broad range of energy related research and development (R&D) projects, including nuclear technologies projects, was conducted at the site. All the nuclear R&D operations in Area IV ceased in 1988. Current efforts are directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and closure of facilities used formore » liquid metal research.« less

  11. Overview of Fuel Rod Simulator Usage at ORNL

    NASA Astrophysics Data System (ADS)

    Ott, Larry J.; McCulloch, Reg

    2004-02-01

    During the 1970s and early 1980s, the Oak Ridge National Laboratory (ORNL) operated large out-of-reactor experimental facilities to resolve thermal-hydraulic safety issues in nuclear reactors. The fundamental research ranged from material mechanical behavior of fuel cladding during the depressurization phase of a loss-of-coolant accident (LOCA) to basic heat transfer research in gas- or sodium-cooled cores. The largest facility simulated the initial phase (less than 1 min. of transient time) of a LOCA in a commercial pressurized-water reactor. The nonnuclear reactor cores of these facilities were mimicked via advanced, highly instrumented electric fuel rod simulators locally manufactured at ORNL. This paper provides an overview of these experimental facilities with an emphasis on the fuel rod simulators.

  12. Low thrust rocket test facility

    NASA Technical Reports Server (NTRS)

    Arrington, Lynn A.; Schneider, Steven J.

    1990-01-01

    A low thrust chemical rocket test facility has recently become operational at the NASA-Lewis. The new facility is used to conduct both long duration and performance tests at altitude over a thruster's operating envelope using hydrogen and oxygen gas for propellants. The facility provides experimental support for a broad range of objectives, including fundamental modeling of fluids and combustion phenomena, the evaluation of thruster components, and life testing of full rocket designs. The major mechanical and electrical systems are described along with aspects of the various optical diagnostics available in the test cell. The electrical and mechanical systems are designed for low down time between tests and low staffing requirements for test operations. Initial results are also presented which illustrate the various capabilities of the cell.

  13. Rangeland livestock production: Developing the concept of sustainability on the Santa Rita Experimental Range

    Treesearch

    George B. Ruyle

    2003-01-01

    The Santa Rita Experimental Range (SRER) was established in 1903 at the behest of concerned stockmen and researchers as the first facility in the United States set aside to study range livestock production. At the time, severe overgrazing of the public domain had seriously reduced carrying capacities of Southwestern rangelands. Researchers on the SRER developed and...

  14. Pinon-juniper management research at Corona Range and Livestock Research Center in Central New Mexico

    Treesearch

    Andres Cibils; Mark Petersen; Shad Cox; Michael Rubio

    2008-01-01

    Description: New Mexico State University's Corona Range and Livestock Research Center (CRLRC) is located in a pinon-juniper (PJ)/grassland ecotone in the southern Basin and Range Province in south central New Mexico. A number of research projects conducted at this facility revolve around soil, plant, livestock, and wildlife responses to PJ woodland management. The...

  15. Streamlined Approach for Environmental Restoration Plan for Corrective Action Unit 489: WWII UXO Sites, Tonopah Test Range, Nevada; May 2005

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bechtel Nevada; U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office

    2005-05-01

    This Streamlined Approach for Environmental Restoration Plan provides the details for the closure of Corrective Action Unit (CAU) 489: WWII UXO Sites, Tonopah Test Range. CAU 489 is located at the Tonopah Test Range and is currently listed in Appendix III of the Federal Facility Agreement and Consent Order of 1996.

  16. Characterization of stormwater at selected South Carolina Department of Transportation maintenance yard and section shed facilities in Ballentine, Conway, and North Charleston, South Carolina, 2010-2012

    USGS Publications Warehouse

    Journey, Celeste A.; Conlon, Kevin J.

    2013-01-01

    The South Carolina Department of Transportation operates section shed and maintenance yard facilities throughout the State. The U.S. Geological Survey conducted a cooperative investigation with the South Carolina Department of Transportation to characterize water-quality constituents that are transported in stormwater from representative maintenance yard and section shed facilities in South Carolina. At a section shed in Ballentine, S.C., stormwater discharges to a retention pond outfall (Ballentine). At the Conway maintenance yard, stormwater in the southernmost section discharges to a pipe outfall (Conway1), and stormwater in the remaining area discharges to a grass-lined ditch (Conway2). At the North Charleston maintenance yard, stormwater discharges from the yard to Turkey Creek through a combination of pipes, ditches, and overland flow; therefore, samples were collected from the main channel of Turkey Creek at the upstream (North Charleston1) and downstream (North Charleston2) limits of the North Charleston maintenance yard facility. The storms sampled during this study had a wide range of rainfall amounts, durations, and intensities at each of the facilities and, therefore, were considered to be reasonably representative of the potential for contaminant transport. At all facilities, stormwater discharge was significantly correlated to rainfall amount and intensity. Event-mean unit-area stormwater discharge increased with increasing impervious surface at the Conway and North Charleston maintenance yards. The Ballentine facility with 79 percent impervious surface had a mean unit-area discharge similar to that of the North Charleston maintenance yard (62 percent impervious surface). That similarity may be attributed, in part, to the effects of the retention pond on the stormwater runoff at the Ballentine facility and to the greater rainfall intensities and amounts at the North Charleston facility. Stormwater samples from the facilities were analyzed for multiple constituents and characteristics. Concentrations of sediment and concentrations of nutrients and fecal indicator bacteria, which are commonly transported with the sediment in stormwater, were measured. Total and dissolved concentrations of six trace metals were determined in the samples. Stormwater samples also were analyzed for organic compounds including 10 herbicides, 18 organochlorine pesticides, 7 Aroclor or polychlorinated biphenyl congeners, 44 volatile organic compounds, and 16 polycyclic aromatic hydrocarbons. Stormwater often transports large quantities of sediment and sediment-bound contaminants, including nutrients and fecal indicator bacteria. Median event-mean concentrations of suspended sediment in stormwater at these facilities ranged from 54 milligrams per liter in Turkey Creek at North Charleston2 to 147 milligrams per liter in stormwater discharging from the Ballentine retention pond outfall. In general, event-mean concentrations of total nitrogen consisted mainly of total Kjeldahl nitrogen (organic nitrogen plus ammonia) rather than nitrate plus nitrite in stormwater, and the median event-mean concentrations of total nitrogen ranged from 1.59 milligrams per liter at the Conway1 pipe outfall to 2.00 milligrams per liter at the Ballentine retention pond outfall. Median event-mean concentrations of total phosphorus in stormwater ranged from 0.15 milligram per liter at the Conway1 outfall to 0.42 milligram per liter in Turkey Creek at North Charleston1. Escherichia coli and enterococcus concentrations often varied by 3 to 4 orders of magnitude in grab samples collected during the “first flush” of stormwater discharging to the sampled outfalls of Turkey Creek. Additionally, enterococcus concentrations consistently were greater than the corresponding Escherichia coli concentrations in stormwater. Specifically, median "first-flush" Escherichia coli concentrations ranged from 30 colonies per 100 milliliters at the Conway1 outfall to 4,359 colonies per 100 milliliters in Turkey Creek at North Charleston2, whereas enterococcus concentrations ranged from 512 colonies per 100 milliliters at the Conway1 outfall to 6,329 colonies per 100 milliliters in Turkey Creek at North Charleston2. In comparison to the proposed South Carolina Department of Health and Environmental Control primary and secondary body contact criterion of 349 colonies per 100 milliliter, stormwater had Escherichia coli concentrations that were greater than the criterion in 4 of the 9 storms at Ballentine retention pond outfall, 1 of the 8 storms at the Conway1 pipe outfall, 5 of the 7 storms at the Conway2 grass-lined ditch outfall, 2 of the 8 storms at North Charleston1 on Turkey Creek, and 8 of the 8 storms at North Charleston2 on Turkey Creek. Of the six trace metals measured in stormwater, only copper and zinc had event-mean concentrations greater than the hardness-dependent South Carolina Department of Health and Environmental Control aquatic life criteria maximum concentrations. Measured dissolved copper event-mean concentrations in stormwater were greater than the criterion in 5 of the samples at the Ballentine facility, 1 of the samples at Conway1, 2 of the samples at Conway2, and 1 of the samples at North Charleston2. Measured dissolved zinc event-mean concentrations in stormwater were greater than the criterion in 3 of the samples at the Ballentine facility, 1 of the samples at Conway1, 2 of the samples at Conway2, and 0 of the samples at North Charleston2. At North Charleston1 upstream from the North Charleston maintenance yard, the measured dissolved trace-metal concentrations were all less than the criterion maximum concentrations. Among the three facilities, Conway1 outfall had the greatest range in event-mean yields in stormwater for total phosphorus, total nitrogen, total suspended solids, and suspended sediment, and both Conway outfalls tended to have median event-mean yields greater than those of the Ballentine and North Charleston yard facilities. "First-flush” yields of Escherichia coli in stormwater were not statistically different among the three facilities. Median event-mean yields of suspended sediment, total nitrogen, total phosphorus, total copper, and total zinc in stormwater demonstrated a strong linear relation to impervious surface at the three facilities. However, median "first-flush" fecal indicator bacterial yields did not have a linear relation to impervious surface.

  17. Kauai Test Facility hazards assessment document

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swihart, A

    1995-05-01

    The Department of Energy Order 55003A requires facility-specific hazards assessment be prepared, maintained, and used for emergency planning purposes. This hazards assessment document describes the chemical and radiological hazards associated with the Kauai Test Facility, Barking Sands, Kauai, Hawaii. The Kauai Test Facility`s chemical and radiological inventories were screened according to potential airborne impact to onsite and offsite individuals. The air dispersion model, ALOHA, estimated pollutant concentrations downwind from the source of a release, taking into consideration the toxicological and physical characteristics of the release site, the atmospheric conditions, and the circumstances of the release. The greatest distance to themore » Early Severe Health Effects threshold is 4.2 kilometers. The highest emergency classification is a General Emergency at the {open_quotes}Main Complex{close_quotes} and a Site Area Emergency at the Kokole Point Launch Site. The Emergency Planning Zone for the {open_quotes}Main Complex{close_quotes} is 5 kilometers. The Emergency Planning Zone for the Kokole Point Launch Site is the Pacific Missile Range Facility`s site boundary.« less

  18. Facility Targeting, Protection and Mission Decision Making Using the VISAC Code

    NASA Technical Reports Server (NTRS)

    Morris, Robert H.; Sulfredge, C. David

    2011-01-01

    The Visual Interactive Site Analysis Code (VISAC) has been used by DTRA and several other agencies to aid in targeting facilities and to predict the associated collateral effects for the go, no go mission decision making process. VISAC integrates the three concepts of target geometric modeling, damage assessment capabilities, and an event/fault tree methodology for evaluating accident/incident consequences. It can analyze a variety of accidents/incidents at nuclear or industrial facilities, ranging from simple component sabotage to an attack with military or terrorist weapons. For nuclear facilities, VISAC predicts the facility damage, estimated downtime, amount and timing of any radionuclides released. Used in conjunction with DTRA's HPAC code, VISAC also can analyze transport and dispersion of the radionuclides, levels of contamination of the surrounding area, and the population at risk. VISAC has also been used by the NRC to aid in the development of protective measures for nuclear facilities that may be subjected to attacks by car/truck bombs.

  19. "Doing" diversity. Holy Cross Health System facilities honor differences in different ways.

    PubMed

    Burnside, G

    1994-12-01

    Holy Cross Health System (HCHS), a South Bend, IN-based organization that stretches from coast to coast, has instituted a diversity initiative to take advantage of demographic changes in its facilities' work forces and the communities they are serving. Launched by Holy Cross's corporate headquarters, the program is carried out by the member facilities, each of which had added its own ideas. HCHS's diversity program has three major components: Consciousness-raising among employees. Activities range from "transcultural rounds" for nursing students to fashion shows in which employees wear costumes from their places of national origin. Educating the larger community. HCHS facilities have been urged to increase awareness of diversity among physicians, patients, vendors, and local business and civic leaders. Strategic thinking. The leaders of HCHS facilities have been advised to integrate diversity into their strategic planning. Leaders are familiarizing themselves with the different cultural, ethnic, and religious groups in the community and preparing their facilities to take full advantage of those groups' contributions.

  20. Space Transportation and Destination Facilities

    NASA Technical Reports Server (NTRS)

    Smitherman, David; McClure, Wallace

    1999-01-01

    The Space Transportation and Destination Facilities section focused on space transportation vehicles-from use of existing vehicles to development of specialized transports-and on space stations, space business parks, space hotels, and other facilities in space of the kind that eventually would provide services for general public space travel (PST) and tourism. For both transportation and destination facilities, the emphasis was on the identification of various strategies to enable a realistic incremental progression in the development and acquisition of such facilities, and the identification of issues that need resolution to enable formation of viable businesses. The approach was to determine the best: (1) Strategies for general PST and tourism development through the description and analysis of a wide range of possible future scenarios. With these scenarios in mind the section then identified. (2) Key issues to be explored. (3) opportunities to eliminate barriers. (4) Recommendations for future actions. (5) Top-level requirements and characteristics for general PST and tourism systems and services that would guide the development of transportation and destination facilities.

  1. The Alto Tandem and Isol Facility at IPN Orsay

    NASA Astrophysics Data System (ADS)

    Franchoo, Serge

    Alto is an infrastructure for experimental nuclear physics in France that comprises both an on-line isotope-separation facility based on the photofission of uranium and a stable-ion beam facility based on a 14.5-MV tandem accelerator. The isotope-separation on-line section of Alto is dedicated to the production of neutron-rich radioactive ion beams (RIB) from the interaction of the γ-flux induced by a 50-MeV 10-µA electron beam in a uranium-carbide target. It is dimensioned for 1011 fissions per second. The RIB facility is exploited in alternating mode with the tandem-based section of Alto, capable of accelerating both light ions for nuclear astrophysics and heavy ions for γ-spectroscopy. The facility thereby offers the opportunity to deliver beams to a large range of physics programmes from nuclear to interdisciplinary physics. In this article, we present the Alto facility as well as some of the highlights and prospects of the experimental programme.

  2. Pressure ulcer prevention in long-term-care facilities: a pilot study implementing standardized nurse aide documentation and feedback reports.

    PubMed

    Horn, Susan D; Sharkey, Siobhan S; Hudak, Sandra; Gassaway, Julie; James, Roberta; Spector, William

    2010-03-01

    To design and facilitate implementation of practice-based evidence changes associated with decreases in pressure ulcer (PrU) development in long-term-care (LTC) facilities and promote these practices as part of routine care. Pre/post observational study. Frail older adult residents in 11 US LTC facilities. Project facilitators assisted frontline multidisciplinary teams (certified nurse aides [CNAs], nurses, and dietitians/dietary aides) to develop streamlined standardized CNA documentation and weekly reports to identify high-risk residents and to integrate clinical reports into day-to-day practice and clinical decision making. The program was called "Real-Time Optimal Care Plans for Nursing Home QI" (Real-Time). Prevalence of PrUs using Centers for Medicare & Medicaid Services (CMS) quality measures (QMs), number of in-house-acquired PrUs, and number and completeness of CNA documentation forms. Seven study LTC facilities that reported data to CMS experienced a combined 33% (SD, 36.1%) reduction in the CMS high-risk PrU QM in 18 months and reduction in newly occurring PrUs (number of ulcers in the fourth quarter of 2003: range, 2-19; and in the third quarter of 2005: range, 1-6). Five of these LTC facilities that fully implemented Real-Time experienced a combined 48.1% (SD, 23.4%) reduction in the CMS high-risk PrU QM. Ten facilities reduced by an average of 2 to 5 their number of CNA documentation forms; CNA weekly documentation completeness reached a consistent level of 90% to 95%, and 8 facilities integrated the use of 2 to 4 weekly project reports in routine clinical decision making. Quality improvement efforts that provide access to focused and timely clinical information, facilitate change, and promote staff working together in multidisciplinary teams impacted clinical outcomes. Prevention of PrUs showed a trend of improvement in facilities that fully integrated tools to identify high-risk residents into day-to-day practice. CNA documentation facilitated better information for clinical decision making. More than 70 additional LTC facilities across the United States are implementing this QI program.

  3. Enhancing Efficiency of Safeguards at Facilities that are Shutdown or Closed-Down, including those being Decommissioned

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moran, B.; Stern, W.; Colley, J.

    International Atomic Energy Agency (IAEA) safeguards involves verification activities at a wide range of facilities in a variety of operational phases (e.g., under construction, start-up, operating, shutdown, closed-down, and decommissioned). Safeguards optimization for each different facility type and operational phase is essential for the effectiveness of safeguards implementation. The IAEA’s current guidance regarding safeguards for the different facility types in the various lifecycle phases is provided in its Design Information Examination (DIE) and Verification (DIV) procedure. 1 Greater efficiency in safeguarding facilities that are shut down or closed down, including those being decommissioned, could allow the IAEA to use amore » greater portion of its effort to conduct other verification activities. Consequently, the National Nuclear Security Administration’s Office of International Nuclear Safeguards sponsored this study to evaluate whether there is an opportunity to optimize safeguards approaches for facilities that are shutdown or closed-down. The purpose of this paper is to examine existing safeguards approaches for shutdown and closed-down facilities, including facilities being decommissioned, and to seek to identify whether they may be optimized.« less

  4. New approaches to ambulatory care facilities in the United Kingdom--an investor developer's perspective.

    PubMed

    Eminson, C; Dawson, D

    1999-01-01

    The purpose of this article is to describe the strategic context within which ambulatory care facilities are being developed, to consider a range of models of care facilities available, and, by drawing on the experience of the authors, to comment on some of the investment and development issues arising from two projects in progress--the community hospitals in Richmond, Yorkshire, in rural north England, and Thames Ditton on the borders of outer south London. In the final section, we consider the possible future of ambulatory care development in the light of government policy.

  5. The RIB facility EXOTIC and its experimental program at INFN-LNL

    NASA Astrophysics Data System (ADS)

    Parascandolo, Concetta

    2018-05-01

    In this contribution, I will present a review about the EXOTIC facility and the research field accessible by using its Radioactive Ion Beams. The EXOTIC facility, installed at the INFN-Laboratori Nazionali di Legnaro, is devoted to the in-flight production of light Radioactive Ion Beams in the energy range between 3-5 MeV/nucleon. The scientific activity performed at EXOTIC concerns different aspects of nuclear physics and nuclear astrophysics, such as, the investigation of reaction mechanisms and nuclear structure, resonant scattering experiments and measurements of nuclear reaction cross sections of astrophysical interest.

  6. A case study of collaborative facilities use in engineering design

    NASA Astrophysics Data System (ADS)

    Monroe, Laura; Pugmire, David

    2010-01-01

    In this paper we describe the use of visualization tools and facilities in the collaborative design of a replacement weapons system, the Reliable Replacement Warhead (RRW). We used not only standard collaboration methods but also a range of visualization software and facilities to bring together domain specialists from laboratories across the country to collaborate on the design and integrate this disparate input early in the design. This was the first time in U.S. weapons history that a weapon had been designed in this collaborative manner. Benefits included projected cost savings, design improvements and increased understanding across the project.

  7. Observatory software for the Maunakea Spectroscopic Explorer

    NASA Astrophysics Data System (ADS)

    Vermeulen, Tom; Isani, Sidik; Withington, Kanoa; Ho, Kevin; Szeto, Kei; Murowinski, Rick

    2016-07-01

    The Canada-France-Hawaii Telescope is currently in the conceptual design phase to redevelop its facility into the new Maunakea Spectroscopic Explorer (MSE). MSE is designed to be the largest non-ELT optical/NIR astronomical telescope, and will be a fully dedicated facility for multi-object spectroscopy over a broad range of spectral resolutions. This paper outlines the software and control architecture envisioned for the new facility. The architecture will be designed around much of the existing software infrastructure currently used at CFHT as well as the latest proven opensource software. CFHT plans to minimize risk and development time by leveraging existing technology.

  8. The financial feasibility of delivering forest treatment residues to bioenergy facilities over a range of diesel fuel and delivered biomass prices

    Treesearch

    Greg Jones; Dan Loeffler; Edward Butler; Susan Hummel; Woodam Chung

    2013-01-01

    Forest treatments have the potential to produce significant quantities of forest residue biomass, which includes the tops and limbs from merchantable trees and smaller trees removed to meet management objectives. We spatially analyzed the sensitivity of financially feasible biomass volumes for delivery to a bioenergy facility across 16 combinations of delivered biomass...

  9. Indian programme on middle atmosphere - Some results

    NASA Astrophysics Data System (ADS)

    Mitra, A. P.

    An account of the very extensive program on the middle atmosphere carried out in India since 1982 is presented. Three rocket ranges (Thumba, SHAR and Balasore), a high altitude balloon facility at Hyderabad, a lidar at Thumba, a laser heterodyning system at Delhi, a meteor radar in Thumba, a network of UVB and multiwavelength radiometers, and a host of conventional ground based facilities scattered over the entire subcontinent were used. These facilities covered a range of latitudes from 8 deg N to 34 deg N and largely around the same longitude zone of 75 deg E. The nature of the Indian effort is the emphasis on campaign mode operations, knitting special rocket and balloon efforts with more conventional ground based activities around specific themes. Major campaigns carried out included: (1) Indo-Soviet Ozone Intercomparison campaigns in 1983 and 1987, (2) Aerosol campaign (3), Ionization and conductivity campaigns, (4) Equatorial Wave Campaign, (5) Antarctic Ozone Hole campaign in Dakshin Gangotri. A few of the more important findings are outlined.

  10. Endangered Species Act and energy facility planning: compliance and conflict

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shreeve, D; Calef, C; Nagy, J

    1978-05-01

    New energy facilities such as coal mines, gasification plants, refineries, and power plants--because of their severe environmental impacts--may, if sited haphazardly, jeopardize endangered species. By law, conflicts between energy-facility siting and endangered species occurrence must be minimized. To assess the likelihood of such conflicts arising, the authors used data from the Fish and Wildlife Service, Endangered Species Office, that describe the species' ranges by county. This data set was matched with county-level occurrences of imminent energy developments to find counties of overlap and hence potential conflict. An index was developed to measure the likelihood of actual conflict occurring in suchmore » counties. Factors determining the index are: numbers of endangered species inhabiting the county, number of energy-related developments, and to what degree the county remains in a wild or undeveloped state. Maps were prepared showing (1) geographic ranges of endangered species by taxonomic groups (mammals, fish, etc.) and (2) counties of conflict.« less

  11. Hydrodynamic Tunneling of 440 GeV SPS protons in Solid Material: Production of Warm Dense Matter at CERN HiRadMat Facility

    NASA Astrophysics Data System (ADS)

    Tahir, Naeem Ahmad; Blanco Sancho, Juan; Schmidt, Ruediger; Shutov, Alaxander; Burkart, Florian; Wollmann, Daniel; Piriz, Antonio Roberto

    2013-10-01

    Numerical simulations have shown that the range of 7 TeV LHC protons in solid matter will be significantly increased due to hydrodynamic tunneling. For example, in solid copper and solid carbon, these protons and the shower can penetrate up to 35 m and 25 m, respectively. However, their corresponding static range in the two materials is 1 m and 3 m, respectively. This will have important implications on machine protection design. In order to validate these simulation results, experiments have been performed at the CERN HiRadMat facility using the 440 GeV SPS proton beam irradiating solid copper cylindrical target. The phenomenon of hydrodynamic tunneling has been experimentally confirmed and good agreement has been found between the simulations and the experimental results. A very interesting outcome of this work is that the HiRadMat facility can be used to generate High Energy Density matter including Warm Dense Matter and strongly coupled plasmas in the laboratory.

  12. A target development program for beamhole spallation neutron sources in the megawatt range

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, G.S.; Atchison, F.

    1995-10-01

    Spallation sources as an alternative to fission neutron sources have been operating successfully up to 160 kW of beam power. With the next generation of these facilities aiming at the medium power range between 0.5 and 5 MW, loads on the targets will be high enough to make present experience of little relevance. With the 0.6 MW continuous facility SINQ under construction, and a 5 MW pulsed facility (ESS) under study in Europe, a research and development program is about to be started which aimes at assessing the limits of stationary and moving solid targets and the feasibility and potentialmore » benefits of flowing liquid metal targets. Apart from theoretical work and examination of existing irradiated material, including used targets from ISIS, it is intended to take advantage of the SINQ solid rod target design to improve the relevant data base by building the target in such a way that individual rods can be equipped as irradiation capsules.« less

  13. Hypervelocity Impact Test Facility: A gun for hire

    NASA Technical Reports Server (NTRS)

    Johnson, Calvin R.; Rose, M. F.; Hill, D. C.; Best, S.; Chaloupka, T.; Crawford, G.; Crumpler, M.; Stephens, B.

    1994-01-01

    An affordable technique has been developed to duplicate the types of impacts observed on spacecraft, including the Shuttle, by use of a certified Hypervelocity Impact Facility (HIF) which propels particulates using capacitor driven electric gun techniques. The fully operational facility provides a flux of particles in the 10-100 micron diameter range with a velocity distribution covering the space debris and interplanetary dust particle environment. HIF measurements of particle size, composition, impact angle and velocity distribution indicate that such parameters can be controlled in a specified, tailored test designed for or by the user. Unique diagnostics enable researchers to fully describe the impact for evaluating the 'targets' under full power or load. Users regularly evaluate space hardware, including solar cells, coatings, and materials, exposing selected portions of space-qualified items to a wide range of impact events and environmental conditions. Benefits include corroboration of data obtained from impact events, flight simulation of designs, accelerated aging of systems, and development of manufacturing techniques.

  14. Brominated flame retardants (BFRs) in air and dust from electronic waste storage facilities in Thailand.

    PubMed

    Muenhor, Dudsadee; Harrad, Stuart; Ali, Nadeem; Covaci, Adrian

    2010-10-01

    This study reports concentrations of brominated flame retardants in dust samples (n=25) and in indoor (n=5) and outdoor air (n=10) (using PUF disk passive air samplers) from 5 electronic and electrical waste (e-waste) storage facilities in Thailand. Concentrations of Sigma(10)PBDEs (BDEs 17, 28, 47, 49, 66, 85, 99, 100, 153 and 154) in outdoor air in the vicinity of e-waste storage facilities ranged from 8 to 150 pg m(-3). Indoor air concentrations ranged from 46 to 350 pg m(-3), with highest concentrations found in a personal computer and printer waste storage room at an e-waste storage facility. These are lower than reported previously for electronic waste treatment facilities in China, Sweden, and the US. Concentrations of Sigma(21)PBDEs (Sigma(10)PBDEs+BDEs 181, 183, 184, 191, 196, 197, 203, 206, 207, 208 and 209), decabromodiphenylethane (DBDPE), decabromobiphenyl (BB-209) in dust were 320-290,000, 43-8700 and <20-2300 ng g(-1) respectively, with the highest concentrations of Sigma(21)PBDEs, BDE-209 and DBDPE in a room used to house discarded TVs, stereos and radios. PBDE concentrations in dust were slightly higher but within the range of those detected in workshop floor dust from an e-waste recycling centre in China. The highest concentration of BB-209 was detected in a room storing discarded personal computers and printers. Consistent with recent reports of elevated ratios of BDE-208:BDE-209 and BDE-183:BDE-209 in household electronics from South China, percentage ratios of BDE-208:BDE-209 (0.64-2.9%) and of BDE-208:BDE-183 (2.8-933%) in dust samples exceeded substantially those present in commercial deca-BDE and octa-BDE formulations. This suggests direct migration of BDE-208 and other nonabrominated BDEs from e-waste to the environment. Under realistic high-end scenarios of occupational exposure to BDE-99, workers in the facilities were exposed above a recently-published Health Based Limit Value for this congener. Reassuringly, estimated exposures to BDE-209 were below the USEPA's reference dose for this congener. Copyright 2010 Elsevier Ltd. All rights reserved.

  15. Incorporating elements of social franchising in government health services improves the quality of infant and young child feeding counselling services at commune health centres in Vietnam.

    PubMed

    Nguyen, Phuong H; Kim, Sunny S; Keithly, Sarah C; Hajeebhoy, Nemat; Tran, Lan M; Ruel, Marie T; Rawat, Rahul; Menon, Purnima

    2014-12-01

    Although social franchising has been shown to enhance the quality of reproductive health services in developing countries, its effect on nutrition services remains unexamined. This study assessed the effects of incorporating elements of social franchising on shaping the quality of infant and young child feeding (IYCF) counselling facilities and services in Vietnam. Process-related data collected 12 months after the launch of the first franchises were used to compare randomly assigned Alive & Thrive-supported health facilities (AT-F, n = 20) with standard facilities (SF, n = 12) across three dimensions of service quality: 'structure', 'process' and 'outcome' that capture the quality of facilities, service delivery, and client perceptions and use, respectively. Data collection included facility assessments (n = 32), staff surveys (n = 96), counselling observations (n = 137), client exit interviews (n = 137) and in-depth interviews with mothers (n = 48). Structure: AT-F were more likely to have an unshared, well-equipped room for nutrition counselling than SF (65.0% vs 10.0%). Compared with SF providers, AT-F staff had better IYCF knowledge (mean score 9.9 vs 8.8, range 0-11 for breastfeeding; mean score 3.6 vs 3.2, range 0-4 for complementary feeding). AT-F providers also demonstrated significantly better interpersonal communication skills (score 9.6 vs 5.1, range 0-13) and offered more comprehensive counselling sessions. Overall utilization of franchises was low (10%). A higher proportion of pregnant women utilized franchise services (48.9%), compared with mothers with children 6-23.9 months (1.4%). There was no quantitative difference in client satisfaction with counselling services between AT-F and SF, but franchise users praised the AT-F for problem solving related to child feeding. Incorporating elements of social franchising significantly enhances the quality of IYCF counselling services within government primary healthcare facilities, particularly their structural and process attributes. Provided that service utilization is improved through demand generation, this model has the potential to impact IYCF practices and child nutrition. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine © The Author 2013; all rights reserved.

  16. The Virginia Space Flight Center model for an integrated federal/commercial launch range

    NASA Astrophysics Data System (ADS)

    Reed, Billie M.

    2000-01-01

    Until 1998, the federal government has been the predominant purchaser of space launches in the U.S. through the purchase of hardware and services. Historically, the government provided the necessary infrastructure for launches from the federal DoD and NASA launch ranges. In this historical model, the federal government had complete ownership, responsibility, liability, and expense for launch activities. In 1998, commercial space launches accounted for 60% of U.S. launches. This growth in commercial launches has increased the demand for launch range services. However, the expense, complexity of activities, and issues over certification of flight safety have deterred the establishment of purely commercial launch sites, with purely commercial being defined as without benefit of capabilities provided by the federal government. Provisions of the Commercial Space Launch Act have enabled DoD and NASA to support commercial launches from government launch ranges on a cost-reimbursable, non-interference basis. The government provides services including use of facilities, tracking and data services, and range and flight safety. In the 1990's, commercial space market projections indicated strong potential for large numbers of commercial satellites to be launched well into the first decade of the 21st century. In response to this significant opportunity for economic growth, several states established spaceports to provide the services necessary to meet these forecast commercial needs. In 1997, NASA agreed to the establishment of the Virginia Space Flight Center (VSFC), a commercial spaceport, at its Wallops Flight Facility. Under this arrangement, NASA agreed to allow the Virginia Commercial Space Flight Authority (VCSFA) to construct facilities on NASA property and agreed to provide launch range and other services in accordance with the Space Act and Commercial Space Launch Act in support of VSFC launch customers. A partnership relationship between NASA and VCSFA has emerged which pairs the strengths of the established NASA Test Range and the state-sponsored, commercial launch facility provider in an attempt to satisfy the needs for flexible, low-cost access to space. The continued viability of the VSFC and other commercial spaceports depend upon access to a space launch and re-entry range safety system that assures the public safety and is accepted by the public and government as authoritative and reliable. DoD and NASA budget problems have resulted in deteriorating services and reliability at federal ranges and has caused fear with respect to their ability to service the growing commercial market. Numerous high level studies have been conducted or are in progress that illuminate the deficiencies. No federal agency has been provided the necessary funding or authority to address the nations diminishing space launch capability. It is questionable as to whether the U.S. can continue to compete in the global space launch market unless these domestic space access problems are rapidly corrected. This paper discusses a potential solution to the lack of a coordinated response in the U.S. to the challenge presented by the global market for space launch facilities and services. .

  17. Space Nuclear Thermal Propulsion (SNTP) Air Force facility

    NASA Technical Reports Server (NTRS)

    Beck, David F.

    1993-01-01

    The Space Nuclear Thermal Propulsion (SNTP) Program is an initiative within the US Air Force to acquire and validate advanced technologies that could be used to sustain superior capabilities in the area or space nuclear propulsion. The SNTP Program has a specific objective of demonstrating the feasibility of the particle bed reactor (PBR) concept. The term PIPET refers to a project within the SNTP Program responsible for the design, development, construction, and operation of a test reactor facility, including all support systems, that is intended to resolve program technology issues and test goals. A nuclear test facility has been designed that meets SNTP Facility requirements. The design approach taken to meet SNTP requirements has resulted in a nuclear test facility that should encompass a wide range of nuclear thermal propulsion (NTP) test requirements that may be generated within other programs. The SNTP PIPET project is actively working with DOE and NASA to assess this possibility.

  18. National Biomedical Tracer Facility. Project definition study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schafer, R.

    We request a $25 million government-guaranteed, interest-free loan to be repaid over a 30-year period for construction and initial operations of a cyclotron-based National Biomedical Tracer Facility (NBTF) in North Central Texas. The NBTF will be co-located with a linear accelerator-based commercial radioisotope production facility, funded by the private sector at approximately $28 million. In addition, research radioisotope production by the NBTF will be coordinated through an association with an existing U.S. nuclear reactor center that will produce research and commercial radioisotopes through neutron reactions. The combined facilities will provide the full range of technology for radioisotope production and research:more » fast neutrons, thermal neutrons, and particle beams (H{sup -}, H{sup +}, and D{sup +}). The proposed NBTF facility includes an 80 MeV, 1 mA H{sup -} cyclotron that will produce proton-induced (neutron deficient) research isotopes.« less

  19. A button - type beam position monitor design for TARLA facility

    NASA Astrophysics Data System (ADS)

    Gündoǧan, M. Tural; Kaya, ć.; Yavaş, Ö.

    2016-03-01

    Turkish Accelerator and Radiation Laboratory in Ankara (TARLA) facility is proposed as an IR FEL and Bremsstrahlung facility as the first facility of Turkish Accelerator Center (TAC). TARLA is essentially proposed to generate oscillator mode FEL in 3-250 microns wavelengths range, will consist of normal conducting injector system with 250 keV beam energy, two superconducting RF accelerating modules in order to accelerate the beam 15-40 MeV. The TARLA facility is expected to provide two modes, Continuous wave (CW) and pulsed mode. Longitudinal electron bunch length will be changed between 1 and 10 ps. The bunch charge will be limited by 77pC. The design of the Button-type Beam Position Monitor for TARLA IR FEL is studied to operate in 1.3 GHz. Mechanical antenna design and simulations are completed considering electron beam parameters of TARLA. Ansoft HFSS and CST Particle Studio is used to compare with results of simulations.

  20. Space Power Facility-Capabilities for Space Environmental Testing Within a Single Facility

    NASA Technical Reports Server (NTRS)

    Sorge, Richard N.

    2013-01-01

    The purpose of this paper is to describe the current and near-term environmental test capabilities of the NASA Glenn Research Center's Space Power Facility (SPF) located at Sandusky, Ohio. The paper will present current and near-term capabilities for conducting electromagnetic interference and compatibility testing, base-shake sinusoidal vibration testing, reverberant acoustic testing, and thermal-vacuum testing. The paper will also present modes of transportation, handling, ambient environments, and operations within the facility to conduct those tests. The SPF is in the midst of completing and activating new or refurbished capabilities which, when completed, will provide the ability to conduct most or all required full-scale end-assembly space simulation tests at a single test location. It is envisioned that the capabilities will allow a customer to perform a wide range of space simulation tests in one facility at reasonable cost.

  1. Factors affecting minority population proximity to hazardous facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nieves, L.A.; Nieves, A.L.

    1995-04-01

    Disproportionate exposure of minority groups to environmental hazards has been attributed to ``environmental racism`` by some authors, without systematic investigation of the factors underlying this exposure pattern. This study examines regional differences in the proximity of African-Americans, Hispanics, Asians, and non-Hispanic Whites to a broad range of facility types and explores the effects of urban and income factors. A statistically significant inverse relationship is found between the percentage of non-Hispanic Whites and virtually all facility categories in all regions. Except for Hispanics in the South, all such associations for minority groups show a direct relationship, though some are nonsignificant. Themore » geographic concentration of facilities is more closely tied to urbanization than to economic factors. Controlling for both urban and economic factors, minority population concentration is still a significant explanatory variable for some facility types in some regions. This finding is most consistent for African-Americans.« less

  2. Progress in magnet design activities for the material plasma exposure experiment

    DOE PAGES

    Duckworth, Robert; Lumsdaine, Arnold; Rapp, Juergen; ...

    2017-07-01

    One of the critical challenges for the development of next generation fusion facilities, such as a Fusion Nuclear Science Facility (FNSF) or DEMO, is the understanding of plasma material interactions (PMI). Making progress in PMI research will require integrated facilities that can provide the types of conditions that will be seen in the first wall and divertor regions of future fusion facilities. In order to meet this need, a new linear plasma facility, the Materials Plasma Exposure Experiment (MPEX), is proposed. In order to generate high ion fluence to simulate fusion divertor conditions, a steady-state plasma will be generated andmore » confined with superconducting magnets. Finally, the on-axis fields will range from 1 to 2.5 T in order to meet the requirements of the various plasma source and heating systems. Details on the pre-conceptual design of the magnets and cryogenic system are presented.« less

  3. Thermal conductivity measurements of epoxy systems at low temperature

    NASA Astrophysics Data System (ADS)

    Rondeaux, F.; Bredy, Ph.; Rey, J. M.

    2002-05-01

    We have developed a specific thermal conductivity measurement facility for solid materials at low temperature (LHe and LN2). At present, the Measurement of Thermal Conductivity of Insulators (MECTI) facility performs measurements on epoxy resin, as well as on bulk materials such as aluminum alloy and on insulators developed at Saclay. Thermal conductivity measurements on pre-impregnated fiber-glass epoxy composite are presented in the temperature range of 4.2 K to 14 K for different thicknesses in order to extract the thermal boundary resistance. We also present results obtained on four different bonding glues (Stycast 2850 FT, Poxycomet F, DP190, Eccobond 285) in the temperature range of 4.2 K to 10 K.

  4. An intercomparison of NEL and DHL water flow facilities using a twin orifice plate flowmeter assembly

    NASA Technical Reports Server (NTRS)

    Dejong, J.; Spencer, E. A.

    1983-01-01

    A 205 mm transfer standard orifice plate meter assembly, consisting of two orifice plates in series separated by a length of pipe containing a flow straightener, was calibrated in two water flow facilities. Results show that the agreement in the characteristics of such a differential pressure transfer standard package is within 0.17% over a 10:1 range from flow rates of approximately 8 to 80 l/sec. When the range over which the comparison was made was limited to that for which the calibration graphs gave straight lines, the agreement is 0.1% in 3 of the 4 calibrations (0.17% in the fourth).

  5. Overview: Development of the National Ignition Facility and the Transition to a User Facility for the Ignition Campaign and High Energy Density Scientific Research

    DOE PAGES

    Moses, E. I.; Lindl, J. D.; Spaeth, M. L.; ...

    2017-03-23

    The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory has been operational since March 2009 and has been transitioning to a user facility supporting ignition science, high energy density stockpile science, national security applications, and fundamental science. The facility has achieved its design goal of 1.8 MJ and 500 TW of 3ω light on target, and has performed target experiments with 1.9 MJ at peak powers of 410 TW. The National Ignition Campaign (NIC), established by the U.S. National Nuclear Security Administration in 2005, was responsible for transitioning NIF from a construction project to a national user facility. Besidesmore » the operation and optimization of the use of the NIF laser, the NIC program was responsible for developing capabilities including target fabrication facilities; cryogenic layering capabilities; over 60 optical, X-ray, and nuclear diagnostic systems; experimental platforms; and a wide range of other NIF facility infrastructure. This study provides a summary of some of the key experimental results for NIF to date, an overview of the NIF facility capabilities, and the challenges that were met in achieving these capabilities. Finally, they are covered in more detail in the papers that follow.« less

  6. Overview: Development of the National Ignition Facility and the Transition to a User Facility for the Ignition Campaign and High Energy Density Scientific Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moses, E. I.; Lindl, J. D.; Spaeth, M. L.

    The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory has been operational since March 2009 and has been transitioning to a user facility supporting ignition science, high energy density stockpile science, national security applications, and fundamental science. The facility has achieved its design goal of 1.8 MJ and 500 TW of 3ω light on target, and has performed target experiments with 1.9 MJ at peak powers of 410 TW. The National Ignition Campaign (NIC), established by the U.S. National Nuclear Security Administration in 2005, was responsible for transitioning NIF from a construction project to a national user facility. Besidesmore » the operation and optimization of the use of the NIF laser, the NIC program was responsible for developing capabilities including target fabrication facilities; cryogenic layering capabilities; over 60 optical, X-ray, and nuclear diagnostic systems; experimental platforms; and a wide range of other NIF facility infrastructure. This study provides a summary of some of the key experimental results for NIF to date, an overview of the NIF facility capabilities, and the challenges that were met in achieving these capabilities. Finally, they are covered in more detail in the papers that follow.« less

  7. Hypervelocity impact facility for simulating materials exposure to impact by space debris

    NASA Technical Reports Server (NTRS)

    Rose, M. F.; Best, S.; Chaloupka, T.; Stephens, B.; Crawford, G.

    1993-01-01

    As a result of man's venturing into space, the local debris contributed by his presence exceeds, at some orbital altitudes, that of the natural component. Man's contribution ranges from fuel residue to large derelect satellites that weigh many kilograms. Current debris models are able to predict the growth of the problem and suggest that spacecraft must employ armor or bumper shields for some orbital altitudes now, and that, the problem will become worse as a function of time. The practical upper limit to the velocity distribution is on the order of 40 km/s and is associated with the natural environment. The maximum velocity of the man-made component is in the 14-16 km/s range. The Long Duration Exposure Facility (LDEF) has verified that the 'high probability of impact' particles are in the microgram to milligram range. These particles can have significant effects on coatings, insulators, and thin metallic layers. The surface of thick materials becomes pitted and the local debris component is enhanced by ejecta from the debris spectrum in a controlled environment. The facility capability is discussed in terms of drive geometry, energetics, velocity distribution, diagnostics, and projectile/debris loading. The facility is currently being used to study impact phenomena on Space Station Freedom's solar array structure, other solar array materials, potential structural materials for use in the station, electrical breakdown in the space environment, and as a means of clarifying or duplicating the impact phenomena on the LDEF surfaces. The results of these experiments are described in terms of the mass/velocity distribution incident on selected samples, crater dynamics, and sample geometry.

  8. Micro-focused Small Angle Neutron Scattering and Imaging for Science and Engineering Using RTP--A Preliminary Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohamed, Abdul Aziz; Al Rashid Megat Ahmad, Megat Harun; Md Idris, Faridah

    2010-01-05

    Malaysian Nuclear Agency's (Nuclear Malaysia) Small Angle Neutron Scattering (SANS) facility--(MYSANS)--is utilizing low flux of thermal neutron at the agency's 1 MW TRIGA reactor. As the design nature of the 8 m SANS facility can allow object resolution in the range between 5 and 80 nm to be obtained. It can be used to study alloys, ceramics and polymers in certain area of problems that relate to samples containing strong scatterers or contrast. The current SANS system at Malaysian Nuclear Agency is only capable to measure Q in limited range with a PSD (128x128) fixed at 4 m from themore » sample. The existing reactor hall that incorporate this MYSANS facility has a layout that prohibits the rebuilding of MYSANS therefore the position between the wavelength selector (HOPG) and sample and the PSD cannot be increased for wider Q range. The flux of the neutron at current sample holder is very low which around 10{sup 3} n/cm{sup 2}/sec. Thus it is important to rebuild the MYSANS to maximize the utilization of neutron. Over the years, the facility has undergone maintenance and some changes have been made. Modification on secondary shutter and control has been carried out to improve the safety level of the instrument. A compact micro-focus SANS method can suit this objective together with an improve cryostat system. This paper will explain some design concept and approaches in achieving higher flux and the modification needs to establish the micro-focused SANS.« less

  9. Variations in the open market costs for prostate cancer surgery: a survey of US hospitals.

    PubMed

    Pate, Scott C; Uhlman, Matthew A; Rosenthal, Jaime A; Cram, Peter; Erickson, Bradley A

    2014-03-01

    To examine variation in the open market cost of a radical prostatectomy (RP) procedure in the US hospitals for an uninsured patient, as many proposals for health care reform highlight the importance of individuals actively participating in selecting care. However, reports suggest that obtaining procedure prices remains challenging and highly variable. We used 2011-2012 US News and World Report rankings to identify a cohort of 100 hospitals making an effort to include an equal distribution of both academic and private centers, city size, and geographic region. Each hospital was called and the essence of the script included a caller stating he was a healthy, uninsured 55-year-old man recently diagnosed with Gleason 3 + 4 prostatic adenocarcinoma with no metastases. Facility, surgeon, and anesthesia fees were solicited. Seventy hospitals provided facility prices. Facility estimates averaged $34,720 (±20,335; range, $10,100-$135,000), which was statistically higher at academics centers. No significant differences were seen by region, population, or hospital ranking. Surgeon and anesthesia fees were provided by 10%, averaging $8280 (±$4282; range, $4028-$18,720). Thirty-three hospitals provided discounted fees for prompt payment averaging 34% (±16%; range, 10%-80%). There is wide variation in pricing for RP, with higher rates found in academic centers. Wide variation in facility costs were observed, and nearly all were unable to provide surgeon and/or anesthesia fees. Currently, it appears to be unacceptably difficult for men with prostate cancer without insurance to obtain prices for an RP procedure. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Timeliness of abnormal screening and diagnostic mammography follow-up at facilities serving vulnerable women.

    PubMed

    Goldman, L Elizabeth; Walker, Rod; Hubbard, Rebecca; Kerlikowske, Karla

    2013-04-01

    Whether timeliness of follow-up after abnormal mammography differs at facilities serving vulnerable populations, such as women with limited education or income, in rural areas, and racial/ethnic minorities is unknown. We examined receipt of diagnostic evaluation after abnormal mammography using 1998-2006 Breast Cancer Surveillance Consortium-linked Medicare claims. We compared whether time to recommended breast imaging or biopsy depended on whether women attended facilities serving vulnerable populations. We characterized a facility by the proportion of mammograms performed on women with limited education or income, in rural areas, or racial/ethnic minorities. We analyzed 30,874 abnormal screening examinations recommended for follow-up imaging across 142 facilities and 10,049 abnormal diagnostic examinations recommended for biopsy across 114 facilities. Women at facilities serving populations with less education or more racial/ethnic minorities had lower rates of follow-up imaging (4%-5% difference, P<0.05), and women at facilities serving more rural and low-income populations had lower rates of biopsy (4%-5% difference, P<0.05). Women undergoing biopsy at facilities serving vulnerable populations had longer times until biopsy than those at facilities serving nonvulnerable populations (21.6 vs. 15.6 d; 95% confidence interval for mean difference 4.1-7.7). The proportion of women receiving recommended imaging within 11 months and biopsy within 3 months varied across facilities (interquartile range, 85.5%-96.5% for imaging and 79.4%-87.3% for biopsy). Among Medicare recipients, follow-up rates were slightly lower at facilities serving vulnerable populations, and among those women who returned for diagnostic evaluation, time to follow-up was slightly longer at facilities that served vulnerable population. Interventions should target variability in follow-up rates across facilities, and evaluate effectiveness particularly at facilities serving vulnerable populations.

  11. Effect of exhaust emissions on carbon monoxide levels in employees working at indoor car wash facilities

    PubMed Central

    Topacoglu, H; Katsakoglou, S; Ipekci, A

    2014-01-01

    Background: Exhaust emissions from motor vehicles threaten the environment and human health. Carbon monoxide (CO) poisoning, especially the use of exhaust gas CO in suicidal attempts is well known in the literature. Recently, indoor car wash facilities established in large shopping malls with closed parking, lots is a new risk area that exposes car wash employees to prolonged periods of high level CO emissions from cars. The aim of this study was to investigate how carboxyhemoglobin (COHb) blood levels of employees get affected in confined areas with relatively poor air circulation. Methods: Twenty male volunteers working in indoor parking car wash facilities were included in the study. Participants were informed about the aim of this study and their consent was obtained. Their pulse COHb levels were measured twice, at the beginning and at the end of the working day using Rad-57 pulse CO-oximeter device, allowing non-invasive measurement of COHb blood levels to compare the changes in their COHb levels before and after work. Results: The mean age of the male volunteers was 29.8 ± 11.9 (range 18-55). While the mean COHb levels measured at the start of the working day was 2.1 ± 2.0 (range 0-9), it was increased to 5.2 ± 3.3 (range 1-15) at the end of work shift (Wilcoxon test, p <0.001). There was a statistically significant difference in COHb levels between the beginning and the end of the work shift in smoker subjects, while the difference was not significant in the non-smoking group (Wilcoxon test, p=0.001, p=0.102, respectively). Conclusion: The COHb blood levels of indoor car wash facility employees is directly impacted and gets elevated by motor vechile exhaust emissions. For the health of the employees at indoor parking car wash facilities, stricter precautions are needed and the government should not give permit to such operations. PMID:25125950

  12. Comprehensive Long-Range Program for Library Services in Wisconsin.

    ERIC Educational Resources Information Center

    Wisconsin State Dept. of Public Instruction, Madison. Div. of Library Services.

    The main areas of concern in this long-range development program to meet the requirements of the Library Services and Construction Act are the following: public library development and facilities, public library services for the disadvantaged, library services for the blind, physically handicapped and institutionalized persons, intertype library…

  13. 75 FR 52039 - Biweekly Notice Applications and Amendments to Facility Operating Licenses Involving No...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-24

    ... modifications which would replace the existing source range and intermediate range excore detector systems with... excore detector systems with equivalent neutron monitoring systems. The new instrumentation will perform... the design earthquake, the double design earthquake, the Hosgri earthquake, and the loss-of-coolant...

  14. Cost and quality of life analysis of HIV self-testing and facility-based HIV testing and counselling in Blantyre, Malawi.

    PubMed

    Maheswaran, Hendramoorthy; Petrou, Stavros; MacPherson, Peter; Choko, Augustine T; Kumwenda, Felistas; Lalloo, David G; Clarke, Aileen; Corbett, Elizabeth L

    2016-02-19

    HIV self-testing (HIVST) has been found to be highly effective, but no cost analysis has been undertaken to guide the design of affordable and scalable implementation strategies. Consecutive HIV self-testers and facility-based testers were recruited from participants in a community cluster-randomised trial ( ISRCTN02004005 ) investigating the impact of offering HIVST in addition to facility-based HIV testing and counselling (HTC). Primary costing studies were undertaken of the HIVST service and of health facilities providing HTC to the trial population. Costs were adjusted to 2014 US$ and INT$. Recruited participants were asked about direct non-medical and indirect costs associated with accessing either modality of HIV testing, and additionally their health-related quality of life was measured using the EuroQol EQ-5D. A total of 1,241 participants underwent either HIVST (n = 775) or facility-based HTC (n = 446). The mean societal cost per participant tested through HIVST (US$9.23; 95 % CI: US$9.14-US$9.32) was lower than through facility-based HTC (US$11.84; 95 % CI: US$10.81-12.86). Although the mean health provider cost per participant tested through HIVST (US$8.78) was comparable to facility-based HTC (range: US$7.53-US$10.57), the associated mean direct non-medical and indirect cost was lower (US$2.93; 95 % CI: US$1.90-US$3.96). The mean health provider cost per HIV positive participant identified through HIVST was higher (US$97.50) than for health facilities (range: US$25.18-US$76.14), as was the mean cost per HIV positive individual assessed for anti-retroviral treatment (ART) eligibility and the mean cost per HIV positive individual initiated onto ART. In comparison to the facility-testing group, the adjusted mean EQ-5D utility score was 0.046 (95 % CI: 0.022-0.070) higher in the HIVST group. HIVST reduces the economic burden on clients, but is a costlier strategy for the health provider aiming to identify HIV positive individuals for treatment. The provider cost of HIVST could be substantially lower under less restrictive distribution models, or if costs of oral fluid HIV test kits become comparable to finger-prick kits used in health facilities.

  15. Defining indicators and standards for tourism impacts in protected areas: Cape Range National Park, Australia.

    PubMed

    Moore, Susan A; Polley, Amanda

    2007-03-01

    Visitors' perceptions of impacts and acceptable standards for environmental conditions can provide essential information for the sustainable management of tourist destinations, especially protected areas. To this end, visitor surveys were administered during the peak visitor season in Cape Range National Park, on the northwest coast of Western Australia and adjacent to the iconic Ningaloo Reef. The central focus was visitors' perceptions regarding environmental conditions and standards for potential indicators. Conditions considered of greatest importance in determining visitors' quality of experience included litter, inadequate disposal of human waste, presence of wildlife, levels of noise, and access to beach and ocean. Standards were determined, based on visitors' perceptions, for a range of site-specific and non-site-specific indicators, with standards for facilities (e.g., acceptable number of parking bays, signs) and for negative environmental impacts (e.g., levels of littering, erosion) sought. The proposed standards varied significantly between sites for the facilities indicators; however, there was no significant difference between sites for environmental impacts. For the facilities, the standards proposed by visitors were closely related to the existing situation, suggesting that they were satisfied with the status quo. These results are considered in the context of current research interest in the efficacy of visitor-derived standards as a basis for protected area management.

  16. Alternatives to Vieques

    DTIC Science & Technology

    2000-08-01

    active training facility in doubt. The Navy and the Marine Corps have explained to Congress and to the American people how important...altitude bombing of land- based targets can be included in such an exercise. Objectives of fleet training exercises We analyzed the objectives of the ...focused on training ranges in the western hemisphere. 13 Range survey We compiled a list of candidate ranges based on three assumptions. First,

  17. Biomarkers of mercury exposure at a mercury recycling facility in Ukraine.

    PubMed

    Gibb, Herman Jones; Kozlov, Kostj; Buckley, Jessie Poulin; Centeno, Jose; Jurgenson, Vera; Kolker, Allan; Conko, Kathryn; Landa, Edward; Panov, Boris; Panov, Yuri; Xu, Hanna

    2008-08-01

    This study evaluates biomarkers of occupational mercury exposure among workers at a mercury recycling operation in Gorlovka, Ukraine. The 29 study participants were divided into three occupational categories for analysis: (1) those who worked in the mercury recycling operation (Group A, n = 8), (2) those who worked at the facility but not in the yard where the recycling was done (Group B, n = 14), and (3) those who did not work at the facility (Group C, n = 7). Urine, blood, hair, and nail samples were collected from the participants, and a questionnaire was administered to obtain data on age, gender, occupational history, smoking, alcohol consumption, fish consumption, tattoos, dental amalgams, home heating system, education, source of drinking water, and family employment in the former mercury mine/smelter located on the site of the recycling facility. Each factor was tested in a univariate regression with total mercury in urine, blood, hair, and nails. Median biomarker concentrations were 4.04 microg/g-Cr (urine), 2.58 microg/L (blood), 3.95 microg/g (hair), and 1.16 microg/g (nails). Occupational category was significantly correlated (p < 0.001) with both blood and urinary mercury concentrations but not with hair or nail mercury. Four individuals had urinary mercury concentrations in a range previously found to be associated with subtle neurological and subjective symptoms (e.g., fatigue, loss of appetite, irritability), and one worker had a urinary mercury concentration in a range associated with a high probability of neurological effects and proteinuria. Comparison of results by occupational category found that workers directly involved with the recycling operation had the highest blood and urinary mercury levels. Those who worked at the facility but were not directly involved with the recycling operation had higher levels than those who did not work at the facility.

  18. Quantification of wind flow in the European Mars Simulation Wind Tunnel Facility

    NASA Astrophysics Data System (ADS)

    Holstein-Rathlou, C.; Merrison, J. P.; Iversen, J. J.; Nornberg, P.

    2012-04-01

    We present the European Mars Simulation Wind Tunnel facility, a unique prototype facility capable of simulating a wide range of environmental conditions, such as those which can be found at the surface of Earth or Mars. The chamber complements several other large-scale simulation facilities at Aarhus University, Denmark. The facility consists of a 50 m3 environmental chamber capable of operating at low pressure (0.02 - 1000 mbar) and cryogenic temperatures (-130 °C up to +60 °C). This chamber houses a re-circulating wind tunnel capable of generating wind speeds up to 25 m/s and has a dust injection system that can produce suspended particulates (aerosols). It employs a unique LED based optical illumination system (solar simulator) and an advanced network based control system. Laser based optoelectronic instrumentation is used to quantify and monitor wind flow, dust suspension and deposition. This involves a commercial Laser Doppler Anemometer (LDA) and a Particle Dynamics Analysis receiver (PDA), which are small laser based instruments specifically designed for measuring wind speed and sizes of particles situated in a wind flow. Wind flow calibrations will be performed with the LDA system and presented. Pressure and temperature calibrations will follow in order to enable the facility to be used for the testing, development, calibration and comparison of e.g. meteorological sensors under a wide range of environmental conditions as well as multi-disciplinary scientific studies. The wind tunnel is accessible to international collaborators and space agencies for instrument testing, calibration and qualification. It has been financed by the European Space Agency (ESA) as well as the Aarhus University Science Faculty and the Villum Kann Rasmussen Foundation.

  19. Determination of six iodotrihalomethanes in drinking water in Korea.

    PubMed

    Woo, Bomi; Park, Ju-Hyun; Kim, Seungki; Lee, Jeongae; Choi, Jong-Ho; Pyo, Heesoo

    2018-06-02

    Trihalomethanes (THMs) are chemicals regulated by Environmental Protection Agency's first drinking water regulation issued after the passage of the Safe Drinking Water Act. Among THMs, iodotrihalomethanes (I-THMs) are produced by treating water containing iodides ion with chlorine or ozone. I-THMs are more carcinogenic and biotoxic than chlorinated or brominated THMs. The purpose of this study was to analyze of I-THMs in drinking water using the liquid-liquid extraction (LLE) method with various extraction solvents. The calibration curves ranged from 0.01 to 20 ng/mL and the correlation coefficient showed a good linearity of 0.99 or more. The method detection limit ranged from 0.01 to 0.10 ng/mL. The accuracy of the LLE method ranged from 99.43 to 112.40%, and its precision ranged from 1.10 to 10.36%. Good recoveries (71.35-118.60%) were obtained for spiked drinking water samples, demonstrating that the LLE method is suitable for the analysis of drinking water samples. Dichloroiodomethane, bromochloroiodomethane, and dibromoiodomethane were identified in drinking water collected from 70 places of water purification plants in Korea. The samples were classified by disinfection systems, regions, seasons, and water sources. The concentration of I-THMs in pre-/postchlorination facilities owing to excess chlorine usage was higher than in ozonization/postchlorination facilities. Moreover, the concentrations of I-THMs were high in the coastal region, because of the large amount of halide ions from the sea. There was no seasonal difference; however, the concentration of I-THMs in pre-/postchlorination facilities increased in spring and summer. The concentration of I-THMs in water sources was high in samples from the Geum River and the Yeongsan and Sumjin River. The concentration and detection frequency of I-THMs in Han River and Nakdong River were high in the coastal region, because of numerous pre-/postchlorination facilities and the abundance of halide ions from the ocean. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. The Precision Expandable Radar Calibration Sphere (PERCS) With Applications for Laser Imaging and Ranging

    NASA Astrophysics Data System (ADS)

    Bernhardt, P.; Nicholas, A.; Thomas, L.; Davis, M.; Hoberman, C.; Davis, M.

    The Naval Research Laboratory will provide an orbiting calibration sphere to be used with ground-based laser imaging telescopes and HF radio systems. The Precision Expandable Radar Calibration Sphere (PERCS) is a practical, reliable, high-performance HF calibration sphere and laser imaging target to orbit at about 600 km altitude. The sphere will be made of a spherical wire frame with aspect independent radar cross section in the 3 to 35 MHz frequency range. The necessary launch vehicle to place the PERCS in orbit will be provided by the Department of Defense Space Test Program. The expandable calibration target has a stowed diameter of 1 meter and a fully deployed diameter of 10.2 meters. A separate deployment mechanism is provided for the sphere. After deployment, the Precision Expandable Radar Calibration Sphere (PERCS) with 180 vertices will be in a high inclination orbit to scatter radio pulses from a number of ground systems, including (1) over-the-horizon (OTH) radars operated by the United States and Australia; (2) high power HF facilities such as HAARP in Alaska, EISCAT in Norway, and Arecibo in Puerto Rico; (3) the chain of high latitude SuperDARN radars used for auroral region mapping; and (4) HF direction finding for Navy ships. With the PERCS satellite, the accuracy of HF radars can be periodically checked for range, elevation, and azimuth errors. In addition, each of the 360 vertices on the PERCS sphere will support an optical retro-reflector for operations with ground laser facilities used to track satellites. The ground laser systems will be used to measure the precise location of the sphere within one cm accuracy and will provide the spatial orientation of the sphere as well as the rotation rate. The Department of Defense facilities that can use the corner-cube reflectors on the PERCS include (1) the Air Force Maui Optical Site (AMOS), (2) the Starfire Optical Range (SOR), and (3) the NRL Optical Test Facility (OTF).

  1. Impact of Dust from Ore Processing Facilities on Rain Water Collection Tanks in a Tropical Environment—The Obvious Source “Ain’t Necessarily So”

    PubMed Central

    Gulson, Brian; Korsch, Michael; Bradshaw, Anthony

    2016-01-01

    Concerns have been expressed that dust from the minerals processing facilities at Karumba Queensland Australia have resulted in elevated lead (Pb) concentrations in rain water tanks. The ores derived from the Century mine some 304 km from the port. High precision Pb isotopic measurements on environmental samples have been undertaken to evaluate the source of Pb in rainwaters and acid digests from roof wipes and gutter wipes. There does not appear to be any relationship between sample location and the processing facility but samples from the area subject to the prevailing winds show the highest contribution of Century Pb. All gutter wipes (82 to 1270 µg Pb/wipe) have contributions of Century ore ranging from 87% to 96%. The contribution of Century ore to five roof wipes (22 to 88 µg Pb/wipe) ranges from 89% to 97% and in the other two samples there is a mix of Century and Broken Hill Pb. Three of the seven rainwater have contributions of Century ore Pb ranging from 33% to 75%. Two of the other four rainwater samples have the highest water Pb concentrations of 88 and 100 µg/L and their isotopic data show Broken Hill Pb contributions ranging from 77% to 80%. The source of the Broken Hill Pb is probably from the galvanized roofing material and/or brass fittings in the rainwater tanks. The discrimination between various sources is only detectable using high precision 204Pb-based isotopic ratios and not the now common inductively coupled plasma mass spectrometry (ICP-MS ) data presentations of the higher abundance isotopes 208Pb, 207Pb and 206Pb. Isotopic results for the waters demonstrate that apportioning blame where there is an obvious point source may not always be the correct conclusion. Nevertheless the isotopic data for the gutter wipes indicates that there was widespread contamination from the processing facilities throughout the town. PMID:26907319

  2. Impact of Dust from Ore Processing Facilities on Rain Water Collection Tanks in a Tropical Environment--The Obvious Source "Ain't Necessarily So".

    PubMed

    Gulson, Brian; Korsch, Michael; Bradshaw, Anthony

    2016-02-22

    Concerns have been expressed that dust from the minerals processing facilities at Karumba Queensland Australia have resulted in elevated lead (Pb) concentrations in rain water tanks. The ores derived from the Century mine some 304 km from the port. High precision Pb isotopic measurements on environmental samples have been undertaken to evaluate the source of Pb in rainwaters and acid digests from roof wipes and gutter wipes. There does not appear to be any relationship between sample location and the processing facility but samples from the area subject to the prevailing winds show the highest contribution of Century Pb. All gutter wipes (82 to 1270 µg Pb/wipe) have contributions of Century ore ranging from 87% to 96%. The contribution of Century ore to five roof wipes (22 to 88 µg Pb/wipe) ranges from 89% to 97% and in the other two samples there is a mix of Century and Broken Hill Pb. Three of the seven rainwater have contributions of Century ore Pb ranging from 33% to 75%. Two of the other four rainwater samples have the highest water Pb concentrations of 88 and 100 µg/L and their isotopic data show Broken Hill Pb contributions ranging from 77% to 80%. The source of the Broken Hill Pb is probably from the galvanized roofing material and/or brass fittings in the rainwater tanks. The discrimination between various sources is only detectable using high precision (204)Pb-based isotopic ratios and not the now common inductively coupled plasma mass spectrometry (ICP-MS ) data presentations of the higher abundance isotopes (208)Pb, (207)Pb and (206)Pb. Isotopic results for the waters demonstrate that apportioning blame where there is an obvious point source may not always be the correct conclusion. Nevertheless the isotopic data for the gutter wipes indicates that there was widespread contamination from the processing facilities throughout the town.

  3. A Model for a Level II Emergency Room

    DTIC Science & Technology

    1989-05-02

    the financial resources which will be consumed, and the Z inm chanQes in the way work will be accomplished. Health care facilities, in general...pursued with the anticipation of action results rather than an academic exercise. The planning process in a health care facility must work within the...Malcolm Grow USAF Medical Center of sufficient size and efficient functional configuration to provide a comprehensive and cost effective range health

  4. Northrop Grumman Corporation's modified U.S. Navy F-5E Shaped Sonic Boom Demonstration (SSBD) aircraft flies over the company's Palmdale, Calif. facilities on Aug. 2, 2003

    NASA Image and Video Library

    2003-08-02

    Northrop Grumman Corporation's modified U.S. Navy F-5E Shaped Sonic Boom Demonstration (SSBD) aircraft flies over the company's Palmdale, California facilities on Aug. 2, 2003. NASA Dryden provided range, air and ground data-gathering support for the SSBD project, which is part of DARPA's Quiet Supersonic Platform (QSP) program.

  5. Federal Research and Development Funding: FY2017

    DTIC Science & Technology

    2016-06-24

    facilities and equipment; does not include physical assets for R&D such as R&D equipment and facilities or routine product testing, quality control...multiagency R&D initiative to advance understanding and control of matter at the nanoscale, where the physical , chemical, and biological properties of...nuclear programs that dated back to the Manhattan Project. Today, DOE conducts basic scientific research in areas ranging from nuclear physics to the

  6. Assessment and Mitigation of Electromagnetic Pulse (EMP) Impacts at Short-pulse Laser Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Jr., C G; Bond, E; Clancy, T

    2009-10-02

    The National Ignition Facility (NIF) will be impacted by electromagnetic pulse (EMP) during normal long-pulse operation, but the largest impacts are expected during short-pulse operation utilizing the Advanced Radiographic Capability (ARC). Without mitigation these impacts could range from data corruption to hardware damage. We describe our EMP measurement systems on Titan and NIF and present some preliminary results and thoughts on mitigation.

  7. Assessment and Mitigation of Electromagnetic Pulse (EMP) Impacts at Short-pulse Laser Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Jr., C G; Bond, E; Clancy, T

    2010-02-04

    The National Ignition Facility (NIF) will be impacted by electromagnetic pulse (EMP) during normal long-pulse operation, but the largest impacts are expected during short-pulse operation utilizing the Advanced Radiographic Capability (ARC). Without mitigation these impacts could range from data corruption to hardware damage. We describe our EMP measurement systems on Titan and NIF and present some preliminary results and thoughts on mitigation.

  8. Can-AMS: The New Accelerator Mass Spectrometry Facility At The University Of Ottawa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kieser, W. E.; Zhao, X.-L.; Clark, I. D.

    2011-06-01

    The Canadian Centre for Accelerator Mass Spectrometry (AMS) at the University of Ottawa will be equipped with a new, 3 MV tandem accelerator with peripheral equipment for the analysis of elements ranging from tritium to the actinides. This facility, along with a wide array of support instrumentation recently funded by the Canada Foundation for Innovation, will be located in a new science building on the downtown campus of the University of Ottawa. In addition to providing the standard AMS measurements on {sup 14}C, {sup 10}Be, {sup 26}Al, {sup 36}Cl and {sup 129}I for earth, environmental, cultural and biomedical sciences, thismore » facility will incorporate the new technologies of anion isobar separation at low energies using RFQ chemical reaction cells for {sup 36}Cl and new heavy element applications, integrated sample combustion and gas ion source for biomedical and environmental {sup 14}C analysis and the use of novel target matrices for expanding the range of applicable elements and simplifying sample preparation, all currently being developed at IsoTrace. This paper will outline the design goals for the new facility, present some details of the new AMS technologies, in particular the Isobar Separator for Anions and discuss the design of the AMS system resulting from these requirements.« less

  9. Physics and technology in the ion-cyclotron range of frequency on Tore Supra and TITAN test facility: implication for ITER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Litaudon, X; Bernard, J. M.; Colas, L.

    2013-01-01

    To support the design of an ITER ion-cyclotron range of frequency heating (ICRH) system and to mitigate risks of operation in ITER, CEA has initiated an ambitious Research & Development program accompanied by experiments on Tore Supra or test-bed facility together with a significant modelling effort. The paper summarizes the recent results in the following areas: Comprehensive characterization (experiments and modelling) of a new Faraday screen concept tested on the Tore Supra antenna. A new model is developed for calculating the ICRH sheath rectification at the antenna vicinity. The model is applied to calculate the local heat flux on Toremore » Supra and ITER ICRH antennas. Full-wave modelling of ITER ICRH heating and current drive scenarios with the EVE code. With 20 MW of power, a current of 400 kA could be driven on axis in the DT scenario. Comparison between DT and DT(3He) scenario is given for heating and current drive efficiencies. First operation of CW test-bed facility, TITAN, designed for ITER ICRH components testing and could host up to a quarter of an ITER antenna. R&D of high permittivity materials to improve load of test facilities to better simulate ITER plasma antenna loading conditions.« less

  10. Services for the Detection and Treatment of Retinopathy of Prematurity in Major Indian Cities: The 11-City 9-State Study.

    PubMed

    Gilbert, Clare; Shukla, Rajan; Kumar, Rakesh; Khera, Ajay; Murthy, G Vs

    2016-11-07

    Control of visual loss from retinopathy of prematurity requires high quality neonatal care, and timely screening and treatment of sight-threatening disease. We assessed services for retinopathy of prematurity provided by ophthalmic training institutions in major Indian cities. Eleven cities were purposefully selected and eye-care facilities were evaluated using predefined criteria. Field teams visited these facilities to collect data by interview and observation using structured questionnaires. 30 training institutions were visited (18 public; 12 not-for-profit); 24 (24/30, 80%) provided a service for retinopathy of prematurity in 58 neonatal units (30 public, 28 private). 15/24 (63%) screened in one unit; six (25%) in 2-3 units and three (12%) in >3 units. Not-for-profit facilities (n=9) screened in more units than public facilities (n=15)(mean (range) 4.5 [1-12] vs 1.1 [1-2] units). Indirect ophthalmoscopy by ophthalmologists was the commonest screening modality but only half of these visited the units weekly. Laser was the commonest treatment, but only half treated babies in the neonatal unit. Annual treatments ranged from 1-200 (mean 39). Eye-care services for retinopathy of prematurity need to expand, particularly in the government sector.

  11. Measurement of oxytetracycline and emamectin benzoate in freshwater sediments downstream of land based aquaculture facilities in the Atlantic Region of Canada.

    PubMed

    Lalonde, Benoit A; Ernst, William; Greenwood, Lyndsay

    2012-09-01

    This study investigated the occurrence of oxytetracycline (OTC) and emamectin benzoate (EB) in sediments located near the effluent outfall from four freshwater aquaculture facilities in Atlantic Canada. While two facilities had no detectable concentrations of EB or OTC, two facilities had detectable concentrations of one or both of these chemicals. Concentrations ranged from <0.05-18 mg/kg to <0.01-2.5 mg/kg for OTC and EB respectively. Although these values could not be compared with freshwater toxicant values, some of the concentrations of EB and OTC detected were higher than LC(50) values calculated for marine invertebrates. OTC concentrations measured in this study are also of a magnitude which has been known to produce resistant bacteria.

  12. TAN HOT SHOP AND SUPPORT FACILITY UTILIZATION STUDY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillips, Ken Crawforth

    2001-11-01

    Impacts to the U.S. Department of Energy (DOE) complex caused by early closure (prior to 2018) and Demolition and Dismantlement (D&D) of the Test Area North (TAN) hot shop and its support facilities are explored in this report. Various possible conditions, such as Standby, Safe Store and Lay-up, that the facility may be placed in prior to eventually being turned over to D&D are addressed. The requirements, impacts, and implications to the facility and to the DOE Complex are discussed for each condition presented in the report. Some details of the report reference the Idaho National Engineering and Environmental Laboratorymore » (INEEL) Spent Nuclear Fuel Life Cycle Baseline Plan, the INEEL 2000 Infrastructure Long Range Plan, and other internal INEEL reports.« less

  13. TAN Hot Shop and Support Facility Utilization Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Picker, B.A.

    2001-11-16

    Impacts to the U.S. Department of Energy (DOE) complex caused by early closure (prior to 2018) and Demolition and Dismantlement (D and D) of the Test Area North (TAN) hot shop and its support facilities are explored in this report. Various possible conditions, such as Standby, Safe Store and Lay-up, that the facility may be placed in prior to eventually being turned over to D and D are addressed. The requirements, impacts, and implications to the facility and to the DOE Complex are discussed for each condition presented in the report. Some details of the report reference the Idaho Nationalmore » Engineering and Environmental Laboratory (INEEL) Spent Nuclear Fuel Life Cycle Baseline Plan, the INEEL 2000 Infrastructure Long Range Plan, and other internal INEEL reports.« less

  14. Astrophysics at the future Rare Isotope Accelerator

    NASA Astrophysics Data System (ADS)

    Smith, Michael; Schatz, Hendrik; Timmes, Frank X.; Wiescher, Michael; Greife, Uwe

    PoS(NIC-IX)179 Significant progress in studies of core collapse supernovae, thermonuclear supernovae, X-ray bursts, novae, and other astrophysical phenomena require intense beams of a wide range of unsta- ble nuclei. While some such beams are currently available and being used for important studies in nuclear astrophysics, the beams are often insufficient in intensity, purity, or available isotopes. It is anticipated that a next-generation radioactive beam facility will be built in the U.S. in the next decade to address these shortcomings, and a Working Group has been established to develop and promote nuclear astrophysics research at this new facility. Many of the topics addressed by the Working Group are relevant for the RIKEN RI Beam Factory, the planned GSI-Fair facility, and other advanced radioactive beam facilities around the world.

  15. On the possibility for precision measurements of differential cross sections for elastic proton–proton scattering at the Protvino accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denisov, S. P., E-mail: denisov@ihep.ru; Kozelov, A. V.; Petrov, V. A.

    Elastic-scattering data were analyzed, and it was concluded on the basis of this analysis that precisionmeasurements of differential cross sections for elastic proton–proton scattering at the accelerator of the Institute for High Energy Physics (IHEP, Protvino, Russia) over a broad momentum-transfer range are of importance and topical interest. The layout of the respective experimental facility detecting the scattered particle and recoil proton and possessing a high momentum-transfer resolution was examined along with the equipment constituting this facility. The facility in question is able to record up to a billion events of elastic proton–proton scattering per IHEP accelerator run (20 days).more » Other lines of physics research with this facility are briefly discussed.« less

  16. Improving heart failure disease management in skilled nursing facilities: lessons learned.

    PubMed

    Dolansky, Mary A; Hitch, Jeanne A; Piña, Ileana L; Boxer, Rebecca S

    2013-11-01

    The purpose of the study was to design and evaluate an improvement project that implemented HF management in four skilled nursing facilities (SNFs). Kotter's Change Management principles were used to guide the implementation. In addition, half of the facilities had an implementation coach who met with facility staff weekly for 4 months and monthly for 5 months. Weekly and monthly audits were performed that documented compliance with eight key aspects of the protocol. Contextual factors were captured using field notes. Adherence to the HF management protocols was variable ranging from 17% to 82%. Facilitators of implementation included staff who championed the project, an implementation coach, and physician involvement. Barriers were high staff turnover and a hierarchal culture. Opportunities exist to integrate HF management protocols to improve SNF care.

  17. Background radiation measurements at high power research reactors

    NASA Astrophysics Data System (ADS)

    Ashenfelter, J.; Balantekin, B.; Baldenegro, C. X.; Band, H. R.; Barclay, G.; Bass, C. D.; Berish, D.; Bowden, N. S.; Bryan, C. D.; Cherwinka, J. J.; Chu, R.; Classen, T.; Davee, D.; Dean, D.; Deichert, G.; Dolinski, M. J.; Dolph, J.; Dwyer, D. A.; Fan, S.; Gaison, J. K.; Galindo-Uribarri, A.; Gilje, K.; Glenn, A.; Green, M.; Han, K.; Hans, S.; Heeger, K. M.; Heffron, B.; Jaffe, D. E.; Kettell, S.; Langford, T. J.; Littlejohn, B. R.; Martinez, D.; McKeown, R. D.; Morrell, S.; Mueller, P. E.; Mumm, H. P.; Napolitano, J.; Norcini, D.; Pushin, D.; Romero, E.; Rosero, R.; Saldana, L.; Seilhan, B. S.; Sharma, R.; Stemen, N. T.; Surukuchi, P. T.; Thompson, S. J.; Varner, R. L.; Wang, W.; Watson, S. M.; White, B.; White, C.; Wilhelmi, J.; Williams, C.; Wise, T.; Yao, H.; Yeh, M.; Yen, Y.-R.; Zhang, C.; Zhang, X.; Prospect Collaboration

    2016-01-01

    Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these facilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are potentially important, even at levels well below those of importance for typical activities. Here we describe a comprehensive series of background assessments at three high-power research reactors, including γ-ray, neutron, and muon measurements. For each facility we describe the characteristics and identify the sources of the background fields encountered. The general understanding gained of background production mechanisms and their relationship to facility features will prove valuable for the planning of any sensitive measurement conducted therein.

  18. Bulk Enthalpy Calculations in the Arc Jet Facility at NASA ARC

    NASA Technical Reports Server (NTRS)

    Thompson, Corinna S.; Prabhu, Dinesh; Terrazas-Salinas, Imelda; Mach, Jeffrey J.

    2011-01-01

    The Arc Jet Facilities at NASA Ames Research Center generate test streams with enthalpies ranging from 5 MJ/kg to 25 MJ/kg. The present work describes a rigorous method, based on equilibrium thermodynamics, for calculating the bulk enthalpy of the flow produced in two of these facilities. The motivation for this work is to determine a dimensionally-correct formula for calculating the bulk enthalpy that is at least as accurate as the conventional formulas that are currently used. Unlike previous methods, the new method accounts for the amount of argon that is present in the flow. Comparisons are made with bulk enthalpies computed from an energy balance method. An analysis of primary facility operating parameters and their associated uncertainties is presented in order to further validate the enthalpy calculations reported herein.

  19. Availability and accessibility of subsidized mammogram screening program in peninsular Malaysia: A preliminary study using travel impedance approach.

    PubMed

    Mahmud, Aidalina; Aljunid, Syed Mohamed

    2018-01-01

    Access to healthcare is essential in the pursuit of universal health coverage. Components of access are availability, accessibility (spatial and non-spatial), affordability and acceptability. Measuring spatial accessibility is common approach to evaluating access to health care. This study aimed to determine the availability and spatial accessibility of subsidised mammogram screening in Peninsular Malaysia. Availability was determined from the number and distribution of facilities. Spatial accessibility was determined using the travel impedance approach to represent the revealed access as opposed to potential access measured by other spatial measurement methods. The driving distance of return trips from the respondent's residence to the facilities was determined using a mapping application. The travel expenditure was estimated by multiplying the total travel distance by a standardised travel allowance rate, plus parking fees. Respondents in this study were 344 breast cancer patients who received treatment at 4 referral hospitals between 2015 and 2016. In terms of availability, there were at least 6 major entities which provided subsidised mammogram programs. Facilities with mammogram involved with these programs were located more densely in the central and west coast region of the Peninsula. The ratio of mammogram facility to the target population of women aged 40-74 years ranged between 1: 10,000 and 1:80,000. In terms of accessibility, of the 3.6% of the respondents had undergone mammogram screening, their mean travel distance was 53.4 km (SD = 34.5, range 8-112 km) and the mean travel expenditure was RM 38.97 (SD = 24.00, range RM7.60-78.40). Among those who did not go for mammogram screening, the estimated travel distance and expenditure had a skewed distribution with median travel distance of 22.0 km (IQR 12.0, 42.0, range 2.0-340.0) and the median travel cost of RM 17.40 (IQR 10.40, 30.00, range 3.40-240.00). Higher travel impedance was noted among those who lived in sub-urban and rural areas. In summary, availability of mammogram facilities was good in the central and west coast of the peninsula. The overall provider-to-population ratio was lower than recommended. Based on the travel impedance approach used, accessibility to subsidised mammogram screening among the respondents was good in urban areas but deprived in other areas. This study was a preliminary study with limitations. Nonetheless, the evidence suggests that actions have to be taken to improve the accessibility to opportunistic mammogram screening in Malaysia in pursuit of universal health coverage.

  20. “Modular Biospheres” New testbed platforms for public environmental education and research

    NASA Astrophysics Data System (ADS)

    Nelson, M.; Dempster, W. F.; Allen, J. P.

    This paper will review the potential of a relatively new type of testbed platform for environmental education and research because of the unique advantages resulting from their material closure and separation from the outside environment. These facilities which we term "modular biospheres", have emerged from research centered on space life support research but offer a wider range of application. Examples of this type of facility include the Bios-3 facility in Russia, the Japanese CEEF (Closed Ecological Experiment Facility), the NASA Kennedy Space Center Breadboard facility, the Biosphere 2 Test Module and the Laboratory Biosphere. Modular biosphere facilities offer unique research and public real-time science education opportunities. Ecosystem behavior can be studied since initial state conditions can be precisely specified and tracked over different ranges of time. With material closure (apart from very small air exchange rate which can be determined), biogeochemical cycles between soil and soil microorganisms, water, plants, and atmosphere can be studied in detail. Such studies offer a major advance from studies conducted with phytotrons which because of their small size, limit the number of organisms to a very small number, and which crucially do not have a high degree of atmospheric, water and overall material closure. Modular biospheres take advantage of the unique properties of closure, as representing a distinct system "metabolism" and therefore are essentially a "mini-world". Though relatively large in comparison with most phytotrons and ecological microcosms, which are now standard research and educational tools, modular biospheres are small enough that they can be economically reconfigured to reflect a changing research agenda. Some design elements include lighting via electric lights and/or sunlight, hydroponic or soil substrate for plants, opaque or glazed structures, and variable volume chambers or other methods to handle atmospheric pressure differences between the facility and the outside environment.

  1. An exploratory study on equity in funding allocation for essential medicines and health supplies in Uganda's public sector.

    PubMed

    Kusemererwa, Donna; Alban, Anita; Obua, Ocwa Thomas; Trap, Birna

    2016-08-30

    To ascertain equity in financing for essential medicines and health supplies (EMHS) in Uganda, this paper explores the relationships among government funding allocations for EMHS, patient load, and medicines availability across facilities at different levels of care. We collected data on EMHS allocations and availability of selected vital medicines from 43 purposively sampled hospitals and the highest level health centers (HC IV), 44 randomly selected lower-level health facilities (HC II, III), and from over 400 facility health information system records and National Medical Stores records. The data were analyzed to determine allocations per patient within and across levels of care and the effects of allocations on product availability. EMHS funding allocations per patient varied widely within facilities at the same level, and allocations per patient between levels overlapped considerably. For example, HC IV allocations per patient ranged from US$0.25 to US$2.14 (1:9 ratio of lowest to highest allocation), and over 75 % of HC IV facilities had the same or lower average allocation per patient than HC III facilities. Overall, 43 % of all the facilities had optimal stock levels, 27 % were understocked, and 30 % were overstocked. Using simulations, we reduced the ratio between the highest and lowest allocations per patient within a level of care to less than two and eliminated the overlap in allocation per patient between levels. Inequity in EMHS allocation is demonstrated by the wide range of funding allocations per patient and the corresponding disparities in medicines availability. We show that using patient load to calculate EMHS allocations has the potential to improve equity significantly. However, more research in this area is urgently needed. The article does not report any results of human participants. It is implemented in collaboration with the Uganda's Ministry of Health, Pharmacy Division.

  2. Physical, Structural and Operational Vulnerability of Critical Facilities in Valle de Chalco Solidaridad, Estado de Mexico, Mexico. Case of study: Avándaro, San Isidro and El Triunfo

    NASA Astrophysics Data System (ADS)

    Garcia Payne, D. G.; Novelo-Casanova, D. A.; Ponce-Pacheco, A. B.; Espinosa-Campos, O.; Huerta-Parra, M.; Reyes-Pimentel, T.; Rodriguez, F.; Benitez-Olivares, I.

    2010-12-01

    Valle de Chalco Solidaridad is located in Mexico City Metropolitan Area in Estado de Mexico, Mexico. In this town there is a sewage canal called “La Compañía”. A wall of this canal collapsed on February 5, 2010 due to heavy rains creating the flooding of four surrounding communities. It is important to point out that this area is frequently exposed to floods. In this work, we consider a critical facility as an essential structure for performance, health care and welfare within a community or/and as a place that can be used as shelter in case of emergency or disaster. Global vulnerability (the sum of the three measured vulnerabilities) of the 25 critical facilities identified in the locations of Avándaro, San Isidro and El Triunfo was assessed using the Community Vulnerability Assessment Tool developed by the National Oceanic and Atmospheric Administration (NOAA). For each critical facility we determined its operational, structural and physical vulnerabilities. For our analysis, we considered the four main natural hazards to which Valle de Chalco is exposed: earthquakes, floods, landslides and sinking. We considered five levels of vulnerability using a scale from 1 to 5, where values range from very low to very high vulnerability, respectively. A critical facilities database was generated by collecting general information for three categories: schools, government and church. Each facility was evaluated considering its location in relation to identified high-risk areas. Our results indicate that in average, the global vulnerability of all facilities is low, however, there are particular cases in which this global vulnerability is high. The average operational vulnerability of the three communities is moderate. The global structural vulnerability (sum of the structural vulnerability for the four analyzed hazards) is moderate. In particular, the structural vulnerability to earthquakes is low, to landslides is very low, to flooding is moderate and to sinking is low. Due to the location of the critical facilities, its global physical vulnerability (sum of the physical vulnerability to the four analyzed hazards) is moderate. Only three facilities have very high physical vulnerability to floods. Churches (six facilities) have the highest operational vulnerability, whereas its structural vulnerability is the lowest. Schools (13 facilities) have the lowest operational vulnerability, nevertheless, there are two schools with very high vulnerability. Regarding the six government facilities, we identified that their structural vulnerability range from moderate to high. As a result of this work, we believe in the importance of strengthening the culture of civil protection within the critical facilities of the communities of Valle de Chalco.

  3. Materials and construction techniques for cryogenic wind tunnel facilities for instruction/research use

    NASA Technical Reports Server (NTRS)

    Morse, S. F.; Roper, A. T.

    1975-01-01

    The results of the cryogenic wind tunnel program conducted at NASA Langley Research Center are presented to provide a starting point for the design of an instructional/research wind tunnel facility. The advantages of the cryogenic concept are discussed, and operating envelopes for a representative facility are presented to indicate the range and mode of operation. Special attention is given to the design, construction and materials problems peculiar to cryogenic wind tunnels. The control system for operation of a cryogenic tunnel is considered, and a portion of a linearized mathematical model is developed for determining the tunnel dynamic characteristics.

  4. The NDCX-II engineering design

    NASA Astrophysics Data System (ADS)

    Waldron, W. L.; Abraham, W. J.; Arbelaez, D.; Friedman, A.; Galvin, J. E.; Gilson, E. P.; Greenway, W. G.; Grote, D. P.; Jung, J.-Y.; Kwan, J. W.; Leitner, M.; Lidia, S. M.; Lipton, T. M.; Reginato, L. L.; Regis, M. J.; Roy, P. K.; Sharp, W. M.; Stettler, M. W.; Takakuwa, J. H.; Volmering, J.; Vytla, V. K.

    2014-01-01

    The Neutralized Drift Compression Experiment (NDCX-II) is a user facility located at Lawrence Berkeley National Laboratory which is uniquely designed for ion-beam-driven high energy density laboratory physics and heavy ion fusion research. Construction was completed in March 2012 and the facility is now in the commissioning phase. A significant amount of engineering was carried out in order to meet the performance parameters required for a wide range of target heating experiments while making the most cost-effective use of high-value hardware available from a decommissioned high current electron induction accelerator. The technical challenges and design of this new ion induction accelerator facility are described.

  5. The NASA JSC Hypervelocity Impact Test Facility (HIT-F)

    NASA Technical Reports Server (NTRS)

    Crews, Jeanne L.; Christiansen, Eric L.

    1992-01-01

    The NASA Johnson Space Center Hypervelocity Impact Test Facility was created in 1980 to study the hypervelocity impact characteristics of composite materials. The facility consists of the Hypervelocity Impact Laboratory (HIRL) and the Hypervelocity Analysis Laboratory (HAL). The HIRL supports three different-size light-gas gun ranges which provide the capability of launching particle sizes from 100 micron spheres to 12.7 mm cylinders. The HAL performs three functions: (1) the analysis of data collected from shots in the HIRL, (2) numerical and analytical modeling to predict impact response beyond test conditions, and (3) risk and damage assessments for spacecraft exposed to the meteoroid and orbital debris environments.

  6. The laboratory astrophysics facility at University College

    NASA Astrophysics Data System (ADS)

    Hyland, A. R.; Smith, R. G.; Robinson, G.

    A laboratory astrophysics facility for the study of the terrestrial analogues of interstellar dust grains is being developed in the Physics Department, University College, Australian Defence Force Academy. The facility consists of a gas handling system for the preparation of samples, a closed-cycle cooler and specimen chamber, and a Fourier Transform Infrared (FTIR) Spectrometer capable of high resolution (0.3/cm) and high sensitivity measurements, currently from 1-25 microns. The layout and construction of the laboratory are described, and the proposed initial experimental program aimed at determining the optical constants of ices, over a wide wavelength range for comparison with astronomical observations, is discussed.

  7. Dose and Dose Risk Caused by Natural Phenomena - Proposed Powder Metallurgy Core Manufacturing Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmes, W.G.

    2001-08-16

    The offsite radiological effects from high velocity straight winds, tornadoes, and earthquakes have been estimated for a proposed facility for manufacturing enriched uranium fuel cores by powder metallurgy. Projected doses range up to 30 mrem/event to the maximum offsite individual for high winds and up to 85 mrem/event for very severe earthquakes. Even under conservative assumptions on meteorological conditions, the maximum offsite dose would be about 20 per cent of the DOE limit for accidents involving enriched uranium storage facilities. The total dose risk is low and is dominated by the risk from earthquakes. This report discusses this test.

  8. Environmental Assessment: Explosive Ordnance Disposal Training Facility, Munitions Storage Facility, and Munitions Maintenance and Inspection Facility Westover Air Reserve Base, Massachusetts

    DTIC Science & Technology

    2003-08-01

    laminate . The thickness of this unit ranges from 10 to more than 250 feet in the Westover ARB area. A glacial till layer of poorly sorted gravel, sand...trucks, concrete trucks, and flatbed trucks. The backhoe would be used with a percussion chisel as well as a lift bucket. Estimates were also...36.00 3.80 83.40 9.00 5.20 Concrete Truck 5 8 2 1.80 0.19 4.17 0.45 0.26 Emissions (lbs) 144.00 15.20 333.60 36.00 20.80 Flatbed Truck 10 8 1

  9. Thermal shock tests with beryllium coupons in the electron beam facility JUDITH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roedig, M.; Duwe, R.; Schuster, J.L.A.

    1995-09-01

    Several grades of American and Russian beryllium have been tested in high heat flux tests by means of an electron beam facility. For safety reasons, major modifications of the facility had to be fulfilled in advance to the tests. The influence of energy densities has been investigated in the range between 1 and 7 MJ/m{sup 2}. In addition the influence of an increasing number of shots at constant energy density has been studied. For all samples, surface profiles have been measured before and after the experiments. Additional information has been gained from scanning electron microscopy, and from metallography.

  10. Patterns and determinants of communal latrine usage in urban poverty pockets in Bhopal, India.

    PubMed

    Biran, A; Jenkins, M W; Dabrase, P; Bhagwat, I

    2011-07-01

    To explore and explain patterns of use of communal latrine facilities in urban poverty pockets. Six poverty pockets with communal latrine facilities representing two management models (Sulabh and municipal) were selected. Sampling was random and stratified by poverty pocket population size. A seventh, community-managed facility was also included. Data were collected by exit interviews with facility users and by interviews with residents from a randomly selected representative sample of poverty pocket households, on social, economic and demographic characteristics of households, latrine ownership, defecation practices, costs of using the facility and distance from the house to the facility. A tally of facility users was kept for 1 day at each facility. Data were analysed using logistic regression modelling to identify determinants of communal latrine usage. Communal latrines differed in their facilities, conditions, management and operating characteristics, and rates of usage. Reported usage rates among non-latrine-owning households ranged from 15% to 100%. There was significant variation in wealth, occupation and household structure across the poverty pockets as well as in household latrine ownership. Households in pockets with municipal communal latrine facilities appeared poorer. Households in pockets with Sulabh-managed communal facilities were significantly more likely to own a household latrine. Determinants of communal facility usage among households without a latrine were access and convenience (distance and opening hours), facility age, cleanliness/upkeep and cost. The ratio of male to female users was 2:1 across all facilities for both adults and children. Provision of communal facilities reduces but does not end the problem of open defecation in poverty pockets. Women appear to be relatively poorly served by communal facilities and, cost is a barrier to use by poorer households. Results suggest improving facility convenience and access and modifying fee structures could lead to increased rates of usage. Attention to possible barriers to usage at household level associated particularly with having school-age children and with pre-school childcare needs may also be warranted. © 2011 Blackwell Publishing Ltd.

  11. Development of an integrated set of research facilities for the support of research flight test

    NASA Technical Reports Server (NTRS)

    Moore, Archie L.; Harney, Constance D.

    1988-01-01

    The Ames-Dryden Flight Research Facility (DFRF) serves as the site for high-risk flight research on many one-of-a-kind test vehicles like the X-29A advanced technology demonstrator, F-16 advanced fighter technology integration (AFTI), AFTI F-111 mission adaptive wing, and F-18 high-alpha research vehicle (HARV). Ames-Dryden is on a section of the historic Muroc Range. The facility is oriented toward the testing of high-performance aircraft, as shown by its part in the development of the X-series aircraft. Given the cost of research flight tests and the complexity of today's systems-driven aircraft, an integrated set of ground support experimental facilities is a necessity. In support of the research flight test of highly advanced test beds, the DFRF is developing a network of facilities to expedite the acquisition and distribution of flight research data to the researcher. The network consists of an array of experimental ground-based facilities and systems as nodes and the necessary telecommunications paths to pass research data and information between these facilities. This paper presents the status of the current network, an overview of current developments, and a prospectus on future major enhancements.

  12. Classification of basic facilities for high-rise residential: A survey from 100 housing scheme in Kajang area

    NASA Astrophysics Data System (ADS)

    Ani, Adi Irfan Che; Sairi, Ahmad; Tawil, Norngainy Mohd; Wahab, Siti Rashidah Hanum Abd; Razak, Muhd Zulhanif Abd

    2016-08-01

    High demand for housing and limited land in town area has increasing the provision of high-rise residential scheme. This type of housing has different owners but share the same land lot and common facilities. Thus, maintenance works of the buildings and common facilities must be well organized. The purpose of this paper is to identify and classify basic facilities for high-rise residential building hoping to improve the management of the scheme. The method adopted is a survey on 100 high-rise residential schemes that ranged from affordable housing to high cost housing by using a snowball sampling. The scope of this research is within Kajang area, which is rapidly developed with high-rise housing. The objective of the survey is to list out all facilities in every sample of the schemes. The result confirmed that pre-determined 11 classifications hold true and can provide the realistic classification for high-rise residential scheme. This paper proposed for redefinition of facilities provided to create a better management system and give a clear definition on the type of high-rise residential based on its facilities.

  13. Does identity shape leadership and management practice? Experiences of PHC facility managers in Cape Town, South Africa.

    PubMed

    Daire, Judith; Gilson, Lucy

    2014-09-01

    In South Africa, as elsewhere, Primary Health Care (PHC) facilities are managed by professional nurses. Little is known about the dimensions and challenges of their job, or what influences their managerial practice. Drawing on leadership and organizational theory, this study explored what the job of being a PHC manager entails, and what factors influence their managerial practice. We specifically considered whether the appointment of professional nurses as facility managers leads to an identity transition, from nurse to manager. The overall intention was to generate ideas about how to support leadership development among PHC facility managers. Adopting case study methodology, the primary researcher facilitated in-depth discussions (about their personal history and managerial experiences) with eight participating facility managers from one geographical area. Other data were collected through in-depth interviews with key informants, document review and researcher field notes/journaling. Analysis involved data triangulation, respondent and peer review and cross-case analysis. The experiences show that the PHC facility manager's job is dominated by a range of tasks and procedures focused on clinical service management, but is expected to encompass action to address the population and public health needs of the surrounding community. Managing with and through others, and in a complex system, requiring self-management, are critical aspects of the job. A range of personal, professional and contextual factors influence managerial practice, including professional identity. The current largely facility-focused management practice reflects the strong nursing identity of managers and broader organizational influences. However, three of the eight managers appear to self-identify an emerging leadership identity and demonstrate related managerial practices. Nonetheless, there is currently limited support for an identity transition towards leadership in this context. Better support for leadership development could include talent-spotting and nurturing, induction and peer-mentoring for newly appointed facility managers, ongoing peer-support once in post and continuous reflective practice. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine © The Author 2014; all rights reserved.

  14. Gaps in the implementation of antenatal syphilis detection and treatment in health facilities across sub-Saharan Africa.

    PubMed

    Kanyangarara, Mufaro; Walker, Neff; Boerma, Ties

    2018-01-01

    Syphilis in pregnancy is an under-recognized public health problem, especially in sub-Saharan Africa which accounts for over 60% of the global burden of syphilis. If left untreated, more than half of maternal syphilis cases will result in adverse pregnancy outcomes including stillbirth and fetal loss, neonatal death, prematurity or low birth weight, and neonatal infections. Achieving universal coverage of antenatal syphilis screening and treatment has been the focus of the global campaign for the elimination of mother-to-child transmission of syphilis. However, little is known about the availability of antenatal syphilis screening and treatment across sub-Saharan Africa. The objective of this study was to estimate the 'likelihood of appropriate care' for antenatal syphilis screening and treatment by analyzing health facility surveys and household surveys conducted from 2010 to 2015 in 12 sub-Saharan African countries. In this secondary data analysis, we linked indicators of health facility readiness to provide antenatal syphilis detection and treatment from Service Provision Assessments (SPAs) and Service Availability and Readiness Assessments (SARAs) to indicators of ANC use from the Demographic and Health Surveys (DHS) to compute estimates of the 'likelihood of appropriate care'. Based on data from 5,593 health facilities that reported offering antenatal care (ANC) services, the availability of syphilis detection and treatment in ANC facilities ranged from 2% to 83%. The availability of syphilis detection and treatment was substantially lower in ANC facilities in West Africa compared to the other sub-regions. Levels of ANC attendance were high (median 94.9%), but only 27% of ANC attendees initiated care at less than 4 months gestation. We estimated that about one in twelve pregnant women received ANC early (<4 months) at a facility ready to provide syphilis detection and treatment (median 8%, range 7-32%). The largest implementation bottleneck identified was low health facility readiness, followed by timeliness of the first ANC visit. While access was fairly high, the low levels of likelihood of antenatal syphilis detection and treatment identified reinforce the need to improve the availability of syphilis rapid diagnostic tests and treatment and the timeliness of antenatal care-seeking across sub-Saharan Africa.

  15. Development of a tactical high-power microwave source using the Plasma Electron Microwave Source (PEMS) concept

    NASA Astrophysics Data System (ADS)

    Dandl, R. A.; Guest, G. E.; Jory, H. R.

    1990-12-01

    The AMPHED facility was used to perform feasibility experiments to explore the generation of high-power microwave pulses from energy stored in a magnetic mirror plasma. The facility uses an open-ended magnetic mirror driven by pulsed or cw c- and x-band sources. Microwave horns were constructed to couple in the frequency range of 2.4 to 4 GHz to whistler waves in the plasma. Spontaneous bursts of microwave radiation in the range of 3 to 5 GHz were observed in the experiments. But the power levels were lower than expected for the whistler wave interaction. It is probable that the hot-electron energy densities achieved were not high enough to approach the threshold of the desired interaction.

  16. Cross sections for the γp→K*0Σ+ reaction at Eγ=1.7 3.0 GeV

    NASA Astrophysics Data System (ADS)

    Hleiqawi, I.; Hicks, K.; Carman, D. S.; Mibe, T.; Niculescu, G.; Tkabladze, A.; Amarian, M.; Ambrozewicz, P.; Anghinolfi, M.; Asryan, G.; Avakian, H.; Bagdasaryan, H.; Baillie, N.; Ball, J. P.; Baltzell, N. A.; Batourine, V.; Battaglieri, M.; Beard, K.; Bedlinskiy, I.; Bellis, M.; Benmouna, N.; Berman, B. L.; Biselli, A. S.; Bouchigny, S.; Boiarinov, S.; Bradford, R.; Branford, D.; Briscoe, W. J.; Brooks, W. K.; Bültmann, S.; Burkert, V. D.; Butuceanu, C.; Calarco, J. R.; Careccia, S. L.; Carnahan, B.; Chen, S.; Cole, P. L.; Collins, P.; Coltharp, P.; Crabb, D.; Crannell, H.; Crede, V.; Cummings, J. P.; Masi, R. De; Vita, R. De; Sanctis, E. De; Degtyarenko, P. V.; Dennis, L.; Deur, A.; Djalali, C.; Dickson, R.; Dodge, G. E.; Donnelly, J.; Doughty, D.; Dugger, M.; Dytman, S.; Dzyubak, O. P.; Egiyan, H.; Egiyan, K. S.; Elouadrhiri, L.; Eugenio, P.; Fedotov, G.; Feldman, G.; Fersch, R.; Feuerbach, R.; Garçon, M.; Gavalian, G.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gonenc, A.; Gothe, R. W.; Griffioen, K. A.; Guidal, M.; Guler, N.; Guo, L.; Gyurjyan, V.; Hakobyan, R. S.; Hardie, J.; Heddle, D.; Hersman, F. W.; Holtrop, M.; Hyde-Wright, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Ito, M. M.; Jenkins, D.; Jo, H. S.; Joo, K.; Juengst, H. G.; Kalantarians, N.; Kellie, J. D.; Khandaker, M.; Kim, K.; Kim, W.; Klein, A.; Klein, F. J.; Klimenko, A. V.; Kossov, M.; Krahn, Z.; Kramer, L. H.; Kubarovsky, V.; Kuhn, J.; Kuhn, S. E.; Kuleshov, S. V.; Lachniet, J.; Laget, J. M.; Langheinrich, J.; Lawrence, D.; Li, J.; Livingston, K.; Lu, H. Y.; Lukashin, K.; MacCormick, M.; McAleer, S.; McKinnon, B.; McNabb, J.; Mecking, B. A.; Mestayer, M. D.; Meyer, C. A.; Mikhailov, K.; Minehart, R.; Mirazita, M.; Miskimen, R.; Mokeev, V.; Moriya, K.; Morrow, S. A.; Moteabbed, M.; Mutchler, G. S.; Munevar, E.; Nadel-Turonski, P.; Nasseripour, R.; Niccolai, S.; Niculescu, I.; Niczyporuk, B. B.; Niroula, M. R.; Niyazov, R. A.; Nozar, M.; Osipenko, M.; Ostrovidov, A. I.; Park, K.; Pasyuk, E.; Paterson, C.; Pierce, J.; Pivnyuk, N.; Pogorelko, O.; Pozdniakov, S.; Preedom, B.; Price, J. W.; Prok, Y.; Protopopescu, D.; Raue, B. A.; Riccardi, G.; Ricco, G.; Ripani, M.; Ritchie, B. G.; Ronchetti, F.; Rosner, G.; Rossi, P.; Sabatié, F.; Salgado, C.; Santoro, J. P.; Sapunenko, V.; Schumacher, R. A.; Serov, V. S.; Sharabian, Y. G.; Smith, E. S.; Smith, L. C.; Sober, D. I.; Stavinsky, A.; Stepanyan, S. S.; Stepanyan, S.; Stokes, B. E.; Stoler, P.; Strakovsky, I. I.; Strauch, S.; Taiuti, M.; Taylor, S.; Tedeschi, D. J.; Thoma, U.; Thompson, R.; Todor, L.; Tkachenko, S.; Tur, C.; Ungaro, M.; Vineyard, M. F.; Vlassov, A. V.; Wang, K.; Weinstein, L. B.; Weygand, D. P.; Whisnant, S.; Williams, M.; Wolin, E.; Wood, M. H.; Yegneswaran, A.; Zana, L.; Zhang, J.; Zhao, B.; Zhao, Z.

    2007-04-01

    Differential cross sections for the reaction γp→K*0Σ+ are presented in the photon energy range of 1.7 to 3.0 GeV. The K*0 was detected by its decay products, K+π-, in the Continuous Electron Beam Accelerator Facility's large acceptance spectrometer (CLAS) detector at the Thomas Jefferson National Accelerator Facility. These data are the first K*0 photoproduction cross sections ever published over a broad range of angles. Comparison with a theoretical model based on the vector and tensor K*-quark couplings shows good agreement with the data, except at forward angles, suggesting that the role of scalar κ meson exchange should be investigated.

  17. Sonic Detection and Ranging (SODAR) Wind Profiler Instrument Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coulter, Richard L.

    2016-04-01

    The SODAR (Sonic Detection and Ranging) wind profiler measures wind profiles and backscattered signal strength between (nominally) 15 meters (m) and 500 m. It operates by transmitting acoustic energy into the atmosphere and measuring the strength and frequency of backscattered energy. The strength of the backscattered signal is determined by the strength of temperature inhomogeneities with size on the order of 10 centimeters (cm). Assuming the scattering elements in the atmosphere are moving with the mean wind, the horizontal wind field can be derived. The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Mobile Facility (AMF)more » has a system developed by Scintec, Inc. that transmits a sequence of frequencies to enhance signal determination.« less

  18. The ISOLDE facility and the HIE-HISOLDE project: Recent highlights

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borge, M. J. G.

    2014-07-23

    The ISOLDE facility at CERN has as objective the production, study and research of nuclei far from stability. The facility provides low energy radioactive beams and post-accelerated beams. In the last 45 years the ISOLDE facility has gathered unique expertise in research with radioactive beams. Over 700 isotopes of more than 70 elements have been used in a wide range of research domains, including cutting edge studies in nuclear structure, atomic physics, nuclear astrophysics, and fundamental interactions. These nuclear probes are also used to do frontier research in solid state and life sciences. There is an on-going upgrade of themore » facility, the HIE-ISOLDE project, which aims to improve the ISOLDE capabilities in a wide front, from an energy increase of the post-accelerated beam to improvements in beam quality and beam purity. The first phase of HIE-ISOLDE will start for physics in the autumn of 2015 with an upgrade of energy for all post-accelerated ISOLDE beams up to 5.5 MeV/u. In this contribution the most recent highlights of the facility are presented.« less

  19. Optically-based Sensor System for Critical Nuclear Facilities Post-Event Seismic Structural Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCallen, David; Petrone, Floriana; Buckle, Ian

    The U.S. Department of Energy (DOE) has ownership and operational responsibility for a large enterprise of nuclear facilities that provide essential functions to DOE missions ranging from national security to discovery science and energy research. These facilities support a number of DOE programs and offices including the National Nuclear Security Administration, Office of Science, and Office of Environmental Management. With many unique and “one of a kind” functions, these facilities represent a tremendous national investment, and assuring their safety and integrity is fundamental to the success of a breadth of DOE programs. Many DOE critical facilities are located in regionsmore » with significant natural phenomenon hazards including major earthquakes and DOE has been a leader in developing standards for the seismic analysis of nuclear facilities. Attaining and sustaining excellence in nuclear facility design and management must be a core competency of the DOE. An important part of nuclear facility management is the ability to monitor facilities and rapidly assess the response and integrity of the facilities after any major upset event. Experience in the western U.S. has shown that understanding facility integrity after a major earthquake is a significant challenge which, lacking key data, can require extensive effort and significant time. In the work described in the attached report, a transformational approach to earthquake monitoring of facilities is described and demonstrated. An entirely new type of optically-based sensor that can directly and accurately measure the earthquake-induced deformations of a critical facility has been developed and tested. This report summarizes large-scale shake table testing of the sensor concept on a representative steel frame building structure, and provides quantitative data on the accuracy of the sensor measurements.« less

  20. 75 FR 49483 - Notice of Availability of the Final Environmental Impact Statement (FEIS) for Training Range and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-13

    ... time period. It also examines potential impacts to surrounding lands and/or local communities. In.... Adverse impacts to other resource areas were negligible or minor. The Final EIS is available at local... Impact Statement (FEIS) for Training Range and Garrison Support Facilities Construction and Operation at...

  1. 25 CFR 170.411 - What may a long-range transportation plan include?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false What may a long-range transportation plan include? 170.411 Section 170.411 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER INDIAN RESERVATION ROADS PROGRAM Planning, Design, and Construction of Indian Reservation Roads Program Facilities...

  2. 78 FR 76060 - Pacific Ocean off the Pacific Missile Range Facility at Barking Sands, Island of Kauai, Hawaii...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-16

    ... military testing and training activities, increases in force protection and other mission-essential... protection, and other mission-essential evolutions. Residents and visitors who typically use these waters off... public access is controlled during the infrequent times of increased force protection, range operations...

  3. Comparative Vibration Levels Perceived Among Species in a Laboratory Animal Facility

    PubMed Central

    Norton, John N; Kinard, Will L; Reynolds, Randall P

    2011-01-01

    The current study was performed to determine the vibration levels that were generated in cages on a ventilated rack by common construction equipment in frequency ranges likely to be perceived by humans, rats, and mice. Vibration generated by the ventilated rack blower caused small but significant increases in some of the abdominal, thoracic, and head resonance frequency ranges (RFR) and sensitivity frequency ranges (SFR) in which each species is most likely to be affected by and perceive vibration, respectively. Vibration caused by various items of construction equipment at 3 ft from the cage were evaluated relative to the RFR and SFR of humans, rats, and mice in 3 anatomic locations. In addition, the vibration levels in the RFR and SFR that resulted from the use of a large jackhammer and were measured at various locations and distances in the facility and evaluated in terms of humans, rats, and mice in 3 anatomic locations. Taken together, the data indicate that a given vibration source generates vibration in frequency ranges that are more likely to affect rats and mice as compared with humans. PMID:22330711

  4. NASA-Ames vertical gun

    NASA Technical Reports Server (NTRS)

    Schultz, P. H.

    1984-01-01

    A national facility, the NASA-Ames vertical gun range (AVGR) has an excellent reputation for revealing fundamental aspects of impact cratering that provide important constraints for planetary processes. The current logistics in accessing the AVGR, some of the past and ongoing experimental programs and their relevance, and the future role of this facility in planetary studies are reviewed. Publications resulting from experiments with the gun (1979 to 1984) are listed as well as the researchers and subjects studied.

  5. Shock Tube and Ballistic Range Facilities at NASA Ames Research Center

    DTIC Science & Technology

    2010-04-01

    in gun performance and launching techniques enabled Mach numbers over 10 to be realized at flight-relevant Reynolds numbers. Although the SSFF...contoured nozzle produced an accelerating supersonic flow with a concomitant exponential decay in density. A two-stage light gas gun fired models upstream...km/s, or Mach 50. Such extreme conditions could not be met by a counterflow facility consisting of the highest performance light gas gun and a

  6. A Patient-specific Approach to Hospital Cost Accounting

    PubMed Central

    Macdonald, Larry K.; Reuter, Louis F.

    1973-01-01

    The hospital facilities and manpower used for the various procedures of a delivery suite are identified and measured as the basis for determining individual patient costs. The method of measuring staff and facility requirements, including the “cost of readiness” and the cost of inherent inefficiencies, generates detailed information that can be used in determining utilization ranges for budgeting decisions, for planning space needs, for personnel scheduling, and for patient billing. PMID:4269322

  7. PRESIDENT KENNEDY TOURS CAPE CANAVERAL FACILITIES WITH DR. KURT H. DEBUS

    NASA Technical Reports Server (NTRS)

    1962-01-01

    President Kennedy and Dr. Kurt Debus head for the car that will take them on a tour of our Nation's space facilities. The President, Vice President, and the Space Committee are among those being briefed at four locations on our space program. The tour includes Marshall Space Flight Center at Huntsville, Alabama, Atlantic Missile Range, Manned Space Flight Center, Houston, Texas, and McDonnell Aircraft at St. Louis, Mo.

  8. Infant feeding-related maternity care practices and maternal report of breastfeeding outcomes.

    PubMed

    Nelson, Jennifer M; Perrine, Cria G; Freedman, David S; Williams, Letitia; Morrow, Brian; Smith, Ruben A; Dee, Deborah L

    2018-02-07

    Evidence-based maternity practices and policies can improve breastfeeding duration and exclusivity. Maternity facilities report practices through the Maternity Practices in Infant Nutrition and Care (mPINC) survey, but individual outcomes, such as breastfeeding duration and exclusivity, are not collected. mPINC data on maternity care practices for 2009 were linked to data from the 2009 Pregnancy Risk Assessment Monitoring System (PRAMS), which collects information on mothers' behaviors and experiences around pregnancy. We calculated total mPINC scores (range 0-100). PRAMS data on any and exclusive breastfeeding at 8 weeks were examined by total mPINC score quartile. Of 15 715 women in our sample, 53.7% were breastfeeding any at 8 weeks, and 29.3% were breastfeeding exclusively. They gave birth at 1016 facilities that had a mean total mPINC score of 65/100 (range 19-99). Care dimension subscores ranged from 41 for facility discharge care to 81 for breastfeeding assistance. In multivariable analysis adjusting for covariates, a positive relationship was found between total mPINC score quartile and both any breastfeeding (quartile 2: odds ratio [OR] 1.40 [95% confidence interval {CI} 1.08-1.83], quartile 3: OR 1.50 [95% CI 1.15-1.96], quartile 4: OR 2.12 [95% CI 1.61-2.78] vs quartile 1) and exclusive breastfeeding (quartile 3: OR 1.41 [95% CI 1.04-1.90], quartile 4: OR 1.89 [95% CI 1.41-2.55] vs quartile 1) at 8 weeks. These data demonstrate that evidence-based maternity care practices and policies are associated with better breastfeeding outcomes. Maternity facilities may evaluate their practices and policies to ensure they are helping mothers achieve their breastfeeding goals. © 2018 Wiley Periodicals, Inc.

  9. Using mobile phone text messaging for malaria surveillance in rural Kenya

    PubMed Central

    2014-01-01

    Background Effective surveillance systems are required to track malaria testing and treatment practices. A 26-week study “SMS for Life” was piloted in five rural districts of Kenya to examine whether SMS reported surveillance data could ensure real-time visibility of accurate data and their use by district managers to impact on malaria case-management. Methods Health workers from 87 public health facilities used their personal mobile phones to send a weekly structured SMS text message reporting the counts of four basic surveillance data elements to a web-based system accessed by district managers. Longitudinal monitoring of SMS reported data through the web-based system and two rounds of cross-sectional health facility surveys were done to validate accuracy of data. Results Mean response rates were 96% with 87% of facilities reporting on time. Fifty-eight per cent of surveillance data parameters were accurately reported. Overall mean testing rates were 37% with minor weekly variations ranging from 32 to 45%. Overall test positivity rate was 24% (weekly range: 17-37%). Ratio of anti-malarial treatments to test positive cases was 1.7:1 (weekly range: 1.3:1–2.2:1). District specific trends showed fluctuating patterns in testing rates without notable improvement over time but the ratio of anti-malarial treatments to test positive cases improved over short periods of time in three out of five districts. Conclusions The study demonstrated the feasibility of using simple mobile phone text messages to transmit timely surveillance data from peripheral health facilities to higher levels. However, accuracy of data reported was suboptimal. Future work should focus on improving quality of SMS reported surveillance data. PMID:24642130

  10. Insight into implementation of facility-based integrated management of childhood illness strategy in a rural district of Sindh, Pakistan.

    PubMed

    Pradhan, Nousheen Akber; Rizvi, Narjis; Sami, Neelofar; Gul, Xaher

    2013-07-05

    Integrated management of childhood illnesses (IMCI) strategy has been proven to improve health outcomes in children under 5 years of age. Pakistan, despite being in the late implementation phase of the strategy, continues to report high under-five mortality due to pneumonia, diarrhea, measles, and malnutrition - the main targets of the strategy. The study determines the factors influencing IMCI implementation at public-sector primary health care (PHC) facilities in Matiari district, Sindh, Pakistan. An exploratory qualitative study with an embedded quantitative strand was conducted. The qualitative part included 16 in-depth interviews (IDIs) with stakeholders which included planners and policy makers at a provincial level (n=5), implementers and managers at a district level (n=3), and IMCI-trained physicians posted at PHC facilities (n=8). Quantitative part included PHC facility survey (n=16) utilizing WHO health facility assessment tool to assess availability of IMCI essential drugs, supplies, and equipments. Qualitative content analysis was used to interpret the textual information, whereas descriptive frequencies were calculated for health facility survey data. The major factors reported to enhance IMCI implementation were knowledge and perception about the strategy and need for separate clinic for children aged under 5 years as potential support factors. The latter can facilitate in strategy implementation through allocated workforce and required equipments and supplies. Constraint factors mainly included lack of clear understanding of the strategy, poor planning for IMCI implementation, ambiguity in defined roles and responsibilities among stakeholders, and insufficient essential supplies and drugs at PHC centers. The latter was further substantiated through health facilities' survey findings, which indicated that none of the facilities had 100% stock of essential supplies and drugs. Only one out of all 16 surveyed facilities had 75% of the total supplies, while 4 out of 16 facilities had 56% of the required IMCI drug stock. The mean availability of supplies ranged from 36.6 to 66%, while the mean availability of drugs ranged from 45.8 to 56.7%. Our findings indicate that the Matiari district has sound implementation potential; however, bottlenecks at health care facility and at health care management level have badly constrained the implementation process. An interdependency exists among the constraining factors, such as lack of sound planning resulting in unclear understanding of the strategy; leading to ambiguous roles and responsibilities among stakeholders which manifest as inadequate availability of supplies and drugs at PHC facilities. Addressing these barriers is likely to have a cumulative effect on facilitating IMCI implementation. On the basis of these findings, we recommend that the provincial Ministry of Health (MoH) and provincial Maternal Neonatal and Child Health (MNCH) program jointly assess the situation and streamline IMCI implementation in the district through sound planning, training, supervision, and logistic support.

  11. Background radiation measurements at high power research reactors

    DOE PAGES

    Ashenfelter, J.; Yeh, M.; Balantekin, B.; ...

    2015-10-23

    Research reactors host a wide range of activities that make use of the intense neutron fluxes generated at these facilities. Recent interest in performing measurements with relatively low event rates, e.g. reactor antineutrino detection, at these facilities necessitates a detailed understanding of background radiation fields. Both reactor-correlated and naturally occurring background sources are potentially important, even at levels well below those of importance for typical activities. Here we describe a comprehensive series of background assessments at three high-power research reactors, including γ-ray, neutron, and muon measurements. For each facility we describe the characteristics and identify the sources of the backgroundmore » fields encountered. Furthermore, the general understanding gained of background production mechanisms and their relationship to facility features will prove valuable for the planning of any sensitive measurement conducted therein.« less

  12. Studies in a transonic rotor aerodynamics and noise facility

    NASA Technical Reports Server (NTRS)

    Wright, S. E.; Lee, D. J.; Crosby, W.

    1984-01-01

    The design, construction and testing of a transonic rotor aerodynamics and noise facility was undertaken, using a rotating arm blade element support technique. This approach provides a research capability intermediate between that of a stationary element in a moving flow and that of a complete rotating blade system, and permits the acoustic properties of blade tip elements to be studied in isolation. This approach is an inexpensive means of obtaining data at high subsonic and transonic tip speeds on the effect of variations in tip geometry. The facility may be suitable for research on broad band noise and discrete noise in addition to high-speed noise. Initial tests were conducted over the Mach number range 0.3 to 0.93 and confirmed the adequacy of the acoustic treatment used in the facility to avoid reflection from the enclosure.

  13. Chapter 24: Strategic Energy Management (SEM) Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stewart, James

    Strategic energy management (SEM) focuses on achieving energy-efficiency improvements through systematic and planned changes in facility operations, maintenance, and behaviors (OM&B) and capital equipment upgrades in large energy-using facilities, including industrial buildings, commercial buildings, and multi-facility organizations such as campuses or communities. Facilities can institute a spectrum of SEM actions, ranging from a simple process for regularly identifying energy-savings actions, to establishing a formal, third-party recognized or certified SEM framework for continuous improvement of energy performance. In general, SEM programs that would be considered part of a utility program will contain a set of energy-reducing goals, principles, and practices emphasizingmore » continuous improvements in energy performance or savings through energy management and an energy management system (EnMS).« less

  14. Respirator use and its impact on particulate matter exposure in aluminum manufacturing facilities.

    PubMed

    Liu, Sa; Noth, Elizabeth; Eisen, Ellen; Cullen, Mark R; Hammond, Katharine

    2018-05-31

    Objectives As part of a large epidemiologic study of particulate health effect, this study aimed to report respirator use among total particulate matter (TPM) samples collected in a major aluminum manufacturing company from 1966‒2013 and evaluate the impact of respirator-use adjustment on exposure estimation. Methods Descriptive analyses were performed to evaluate respirator use across facilities and by facility type and job. Protection factors were applied to TPM measurements for recorded respirator use. Estimated TPM exposure for each job ‒ before and after respirator-use adjustment ‒ were compared to assess the impact of adjustment on exposure estimation. Results Respirator use was noted for 37% of 12 402 full-shift personal TPM samples. Measured TPM concentration ranged from less than detectable to 8220 mg/m3, with arithmetic mean, median and standard deviation being 10.6, 0.87 and 130 mg/m 3 , respectively. Respirators were used more often in smelting facilities (52% of TPM measurements) than in fabricating (17%) or refinery facilities (28%) (P<0.01). Sixty-two percent of jobs in smelting facilities were subject to respirator-use adjustment, whereas it was 20% and 70% in fabricating and refinery facilities, respectively. Applying protection factors to TPM measurements significantly reduced estimated job mean TPM exposures and changed exposure categories in these facilities, with larger impact in smelting than fabricating facilities. Conclusions Respirator use varied by time, facility and job. Adjusting respirator use resulted in differential impact in smelting and fabricating facilities, which will need to be incorporated into ongoing epidemiologic studies accordingly.

  15. Medical surveillance and programs on industrial hygiene at RCRA facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, T.E.

    1994-12-31

    Some special areas where much progress in industrial hygiene and safety has been made in the past few years are; training, personal protective equipment, uniforms, personal monitoring, area monitoring, and medical surveillance. Before one can begin to construct programs for worker protection, some knowledge of potential exposures must be gained. The best place to start is the Waste Analysis Plan, and the list of wastes that a particular site is authorized to receive. Waste Codes are listed within a facility`s Part A and Part B permits. Actual facility receipt of wastes are well documented within Load Records and other documentation.more » A facility`s training program forms the heart of a health and safety program. Every TSD facility should have developed a matrix of job titles and required training. Every facility must also make a commitment to providing a wide range of personal protective equipment, including a wide array of disposables. Some facilities will benefit from the occasional use of the newer respirator quantitative fit-testing devices. All facilities are urged to rent or borrow this type of equipment periodically. Quantitative respirator fit-testers are capable of revealing important deficiencies in a respirator program. Providing uniforms is a newer means of protecting workers. The use of uniforms is an effective means for addressing the idea of carry-home-waste. The use of disposables including boots, must be integrated into a Uniform Program if the program is to be effective. In addition, employees must strictly understand that uniforms must not leave the facility at any time, including lunch time.« less

  16. Calcine Waste Storage at the Idaho Nuclear Technology and Engineering Center

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Staiger, Merle Daniel; M. C. Swenson

    2005-01-01

    This report documents an inventory of calcined waste produced at the Idaho Nuclear Technology and Engineering Center during the period from December 1963 to May 2000. The report was prepared based on calciner runs, operation of the calcined solids storage facilities, and miscellaneous operational information that establishes the range of chemical compositions of calcined waste stored at Idaho Nuclear Technology and Engineering Center. The report will be used to support obtaining permits for the calcined solids storage facilities, possible treatment of the calcined waste at the Idaho National Engineering and Environmental Laboratory, and to ship the waste to an off-sitemore » facility including a geologic repository. The information in this report was compiled from calciner operating data, waste solution analyses and volumes calcined, calciner operating schedules, calcine temperature monitoring records, and facility design of the calcined solids storage facilities. A compact disk copy of this report is provided to facilitate future data manipulations and analysis.« less

  17. Palliative Care Matters: Lessons From the Loss of a Facility Dog.

    PubMed

    Holman, Elizabeth; Levy, Cari; Kennedy, Brenda

    2018-01-01

    Animal-assisted intervention is gaining attention as a stress reduction modality. Quantitative data demonstrate its effectiveness, as a recent study published in AJHPM supported that a Veterans Affairs (VA) hospital facility dog paired with a palliative care psychologist had a measurable impact on salivary cortisol levels and heart rate in hospitalized veterans. There remains an important role for qualitative insights. The Denver VA palliative care team learned a range of lessons from the sudden loss of their facility dog, many of which relate directly to palliative care. The importance of communication, adjusting to changing teams, and the need for consultation and support based in shared goals and values all became evident in the course of the facility dog's illness. After her death, lessons shifted to grief and loss and how providers, patients, and a community care for each other. People's connection to the facility dog ultimately proved to be a critical factor in helping them connect with one another.

  18. Murine norovirus infection in Brazilian animal facilities

    PubMed Central

    Rodrigues, Daniele Masselli; Moreira, Josélia Cristina de Oliveira; Lancellotti, Marcelo; Gilioli, Rovilson; Corat, Marcus Alexandre Finzi

    2016-01-01

    Murine norovirus (MNV) is a single-stranded positive-sense RNA virus of the Caliciviridae family. MNV has been reported to infect laboratory mice with the ability to cause lethal infections in strains lacking components of the innate immune response. Currently, MNV is considered the most prevalent infectious agent detected in laboratory mouse facilities. In this study, mice in 22 laboratory animal facilities within Brazil were analyzed for MNV infection. Using primers targeting a conserved region of the viral capsid, MNV was detected by RT-PCR in 137 of 359 mice from all 22 facilities. Nucleotide sequencing and phylogenetic analysis of the capsid region from the viral genome showed identity ranging from 87% to 99% when compared to reported MNV sequences. In addition, RAW264.7 cells inoculated with a mouse fecal suspension displayed cytopathic effect after the fifth passage. This study represents the first report of MNV in mouse colonies in Brazilian laboratory animal facilities, emphasizing the relevance of a health surveillance program in such environments. PMID:28049885

  19. The n_TOF facility: Neutron beams for challenging future measurements at CERN

    NASA Astrophysics Data System (ADS)

    Chiaveri, E.; Aberle, O.; Andrzejewski, J.; Audouin, L.; Bacak, M.; Balibrea, J.; Barbagallo, M.; Bečvář, F.; Berthoumieux, E.; Billowes, J.; Bosnar, D.; Brown, A.; Caamaño, M.; Calviño, F.; Calviani, M.; Cano-Ott, D.; Cardella, R.; Casanovas, A.; Cerutti, F.; Chen, Y. H.; Colonna, N.; Cortés, G.; Cortés-Giraldo, M. A.; Cosentino, L.; Damone, L. A.; Diakaki, M.; Domingo-Pardo, C.; Dressler, R.; Dupont, E.; Durán, I.; Fernández-Domínguez, B.; Ferrari, A.; Ferreira, P.; Finocchiaro, P.; Göbel, K.; García, A. R.; Gawlik, A.; Gilardoni, S.; Glodariu, T.; Gonçalves, I. F.; González, E.; Griesmayer, E.; Guerrero, C.; Gunsing, F.; Harada, H.; Heinitz, S.; Heyse, J.; Jenkins, D. G.; Jericha, E.; Käppeler, F.; Kadi, Y.; Kalamara, A.; Kavrigin, P.; Kimura, A.; Kivel, N.; Kokkoris, M.; Krtička, M.; Kurtulgil, D.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Lerendegui-Marco, J.; Meo, S. Lo; Lonsdale, S. J.; Macina, D.; Marganiec, J.; Martínez, T.; Masi, A.; Massimi, C.; Mastinu, P.; Mastromarco, M.; Maugeri, E. A.; Mazzone, A.; Mendoza, E.; Mengoni, A.; Milazzo, P. M.; Mingrone, F.; Musumarra, A.; Negret, A.; Nolte, R.; Oprea, A.; Patronis, N.; Pavlik, A.; Perkowski, J.; Porras, I.; Praena, J.; Quesada, J. M.; Radeck, D.; Rauscher, T.; Reifarth, R.; Rubbia, C.; Ryan, J. A.; Sabaté-Gilarte, M.; Saxena, A.; Schillebeeckx, P.; Schumann, D.; Smith, A. G.; Sosnin, N. V.; Stamatopoulos, A.; Tagliente, G.; Tain, J. L.; Tarifeño-Saldivia, A.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Vannini, G.; Variale, V.; Vaz, P.; Ventura, A.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Warren, S.; Woods, P. J.; Wright, T.; Žugec, P.

    2017-09-01

    The CERN n_TOF neutron beam facility is characterized by a very high instantaneous neutron flux, excellent TOF resolution at the 185 m long flight path (EAR-1), low intrinsic background and coverage of a wide range of neutron energies, from thermal to a few GeV. These characteristics provide a unique possibility to perform high-accuracy measurements of neutron-induced reaction cross-sections and angular distributions of interest for fundamental and applied Nuclear Physics. Since 2001, the n_TOF Collaboration has collected a wealth of high quality nuclear data relevant for nuclear astrophysics, nuclear reactor technology, nuclear medicine, etc. The overall efficiency of the experimental program and the range of possible measurements has been expanded with the construction of a second experimental area (EAR-2), located 20 m on the vertical of the n_TOF spallation target. This upgrade, which benefits from a neutron flux 30 times higher than in EAR-1, provides a substantial extension in measurement capabilities, opening the possibility to collect data on neutron cross-section of isotopes with short half-lives or available in very small amounts. This contribution will outline the main characteristics of the n_TOF facility, with special emphasis on the new experimental area. In particular, we will discuss the innovative features of the EAR-2 neutron beam that make possible to perform very challenging measurements on short-lived radioisotopes or sub-mg samples, out of reach up to now at other neutron facilities around the world. Finally, the future perspectives of the facility will be presented.

  20. Prevalence of inappropriate medication use in residential long-term care facilities for the elderly: A systematic review.

    PubMed

    Storms, Hannelore; Marquet, Kristel; Aertgeerts, Bert; Claes, Neree

    2017-12-01

    Multi-morbidity and polypharmacy of the elderly population enhances the probability of elderly in residential long-term care facilities experiencing inappropriate medication use. The aim is to systematically review literature to assess the prevalence of inappropriate medication use in residential long-term care facilities for the elderly. Databases (MEDLINE, EMBASE) were searched for literature from 2004 to 2016 to identify studies examining inappropriate medication use in residential long-term care facilities for the elderly. Studies were eligible when relying on Beers criteria, STOPP, START, PRISCUS list, ACOVE, BEDNURS or MAI instruments. Inappropriate medication use was defined by the criteria of these seven instruments. Twenty-one studies met inclusion criteria. Seventeen studies relied on a version of Beers criteria with prevalence ranging between 18.5% and 82.6% (median 46.5%) residents experiencing inappropriate medication use. A smaller range, from 21.3% to 63.0% (median 35.1%), was reported when considering solely the 10 studies that used Beers criteria updated in 2003. Prevalence varied from 23.7% to 79.8% (median 61.1%) in seven studies relying on STOPP. START and ACOVE were relied on in respectively four (prevalence: 30.5-74.0%) and two studies (prevalence: 28.9-58.0%); PRISCUS, BEDNURS and MAI were all used in one study each. Beers criteria of 2003 and STOPP were most frequently used to determine inappropriate medication use in residential long-term care facilities. Prevalence of inappropriate medication use strongly varied, despite similarities in research design and assessment with identical instrument(s).

  1. Prevalence of inappropriate medication use in residential long-term care facilities for the elderly: A systematic review

    PubMed Central

    Storms, Hannelore; Marquet, Kristel; Aertgeerts, Bert; Claes, Neree

    2017-01-01

    Abstract Background: Multi-morbidity and polypharmacy of the elderly population enhances the probability of elderly in residential long-term care facilities experiencing inappropriate medication use. Objectives: The aim is to systematically review literature to assess the prevalence of inappropriate medication use in residential long-term care facilities for the elderly. Methods: Databases (MEDLINE, EMBASE) were searched for literature from 2004 to 2016 to identify studies examining inappropriate medication use in residential long-term care facilities for the elderly. Studies were eligible when relying on Beers criteria, STOPP, START, PRISCUS list, ACOVE, BEDNURS or MAI instruments. Inappropriate medication use was defined by the criteria of these seven instruments. Results: Twenty-one studies met inclusion criteria. Seventeen studies relied on a version of Beers criteria with prevalence ranging between 18.5% and 82.6% (median 46.5%) residents experiencing inappropriate medication use. A smaller range, from 21.3% to 63.0% (median 35.1%), was reported when considering solely the 10 studies that used Beers criteria updated in 2003. Prevalence varied from 23.7% to 79.8% (median 61.1%) in seven studies relying on STOPP. START and ACOVE were relied on in respectively four (prevalence: 30.5–74.0%) and two studies (prevalence: 28.9–58.0%); PRISCUS, BEDNURS and MAI were all used in one study each. Conclusions: Beers criteria of 2003 and STOPP were most frequently used to determine inappropriate medication use in residential long-term care facilities. Prevalence of inappropriate medication use strongly varied, despite similarities in research design and assessment with identical instrument(s). PMID:28271916

  2. Validity of self-assessment in a quality improvement collaborative in Ecuador.

    PubMed

    Hermida, Jorge; Broughton, Edward I; Miller Franco, Lynne

    2011-12-01

    Health care quality improvement (QI) efforts commonly use self-assessment to measure compliance with quality standards. This study investigates the validity of self-assessment of quality indicators. Cross sectional. A maternal and newborn care improvement collaborative intervention conducted in health facilities in Ecuador in 2005. Four external evaluators were trained in abstracting medical records to calculate six indicators reflecting compliance with treatment standards. About 30 medical records per month were examined at 12 participating health facilities for a total of 1875 records. The same records had already been reviewed by QI teams at these facilities (self-assessment). Overall compliance, agreement (using the Kappa statistic), sensitivity and specificity were analyzed. We also examined patterns of disagreement and the effect of facility characteristics on levels of agreement. External evaluators reported compliance of 69-90%, while self-assessors reported 71-92%, with raw agreement of 71-95% and Kappa statistics ranging from fair to almost perfect agreement. Considering external evaluators as the gold standard, sensitivity of self-assessment ranged from 90 to 99% and specificity from 48 to 86%. Simpler indicators had fewer disagreements. When disagreements occurred between self-assessment and external valuators, the former tended to report more positive findings in five of six indicators, but this tendency was not of a magnitude to change program actions. Team leadership, understanding of the tools and facility size had no overall impact on the level of agreement. When compared with external evaluation (gold standard), self-assessment was found to be sufficiently valid for tracking QI team performance. Sensitivity was generally higher than specificity. Simplifying indicators may improve validity.

  3. The Advanced Technology Development Center (ATDC)

    NASA Technical Reports Server (NTRS)

    Clements, G. R.; Willcoxon, R. (Technical Monitor)

    2001-01-01

    NASA is building the Advanced Technology Development Center (ATDC) to provide a 'national resource' for the research, development, demonstration, testing, and qualification of Spaceport and Range Technologies. The ATDC will be located at Space Launch Complex 20 (SLC-20) at Cape Canaveral Air Force Station (CCAFS) in Florida. SLC-20 currently provides a processing and launch capability for small-scale rockets; this capability will be augmented with additional ATDC facilities to provide a comprehensive and integrated in situ environment. Examples of Spaceport Technologies that will be supported by ATDC infrastructure include densified cryogenic systems, intelligent automated umbilicals, integrated vehicle health management systems, next-generation safety systems, and advanced range systems. The ATDC can be thought of as a prototype spaceport where industry, government, and academia, in partnership, can work together to improve safety of future space initiatives. The ATDC is being deployed in five separate phases. Major ATDC facilities will include a Liquid Oxygen Area; a Liquid Hydrogen Area, a Liquid Nitrogen Area, and a multipurpose Launch Mount; 'Iron Rocket' Test Demonstrator; a Processing Facility with a Checkout and Control System; and Future Infrastructure Developments. Initial ATDC development will be completed in 2006.

  4. Counting the costs of accreditation in acute care: an activity-based costing approach

    PubMed Central

    Mumford, Virginia; Greenfield, David; Hogden, Anne; Forde, Kevin; Westbrook, Johanna; Braithwaite, Jeffrey

    2015-01-01

    Objectives To assess the costs of hospital accreditation in Australia. Design Mixed methods design incorporating: stakeholder analysis; survey design and implementation; activity-based costs analysis; and expert panel review. Setting Acute care hospitals accredited by the Australian Council for Health Care Standards. Participants Six acute public hospitals across four States. Results Accreditation costs varied from 0.03% to 0.60% of total hospital operating costs per year, averaged across the 4-year accreditation cycle. Relatively higher costs were associated with the surveys years and with smaller facilities. At a national level these costs translate to $A36.83 million, equivalent to 0.1% of acute public hospital recurrent expenditure in the 2012 fiscal year. Conclusions This is the first time accreditation costs have been independently evaluated across a wide range of hospitals and highlights the additional cost burden for smaller facilities. A better understanding of the costs allows policymakers to assess alternative accreditation and other quality improvement strategies, and understand their impact across a range of facilities. This methodology can be adapted to assess international accreditation programmes. PMID:26351190

  5. Education and public engagement in observatory operations

    NASA Astrophysics Data System (ADS)

    Gabor, Pavel; Mayo, Louis; Zaritsky, Dennis

    2016-07-01

    Education and public engagement (EPE) is an essential part of astronomy's mission. New technologies, remote observing and robotic facilities are opening new possibilities for EPE. A number of projects (e.g., Telescopes In Education, MicroObservatory, Goldstone Apple Valley Radio Telescope and UNC's Skynet) have developed new infrastructure, a number of observatories (e.g., University of Arizona's "full-engagement initiative" towards its astronomy majors, Vatican Observatory's collaboration with high-schools) have dedicated their resources to practical instruction and EPE. Some of the facilities are purpose built, others are legacy telescopes upgraded for remote or automated observing. Networking among institutions is most beneficial for EPE, and its implementation ranges from informal agreements between colleagues to advanced software packages with web interfaces. The deliverables range from reduced data to time and hands-on instruction while operating a telescope. EPE represents a set of tasks and challenges which is distinct from research applications of the new astronomical facilities and operation modes. In this paper we examine the experience with several EPE projects, and some lessons and challenges for observatory operation.

  6. Study on patient-induced radioactivity during proton treatment in hengjian proton medical facility.

    PubMed

    Wu, Qingbiao; Wang, Qingbin; Liang, Tianjiao; Zhang, Gang; Ma, Yinglin; Chen, Yu; Ye, Rong; Liu, Qiongyao; Wang, Yufei; Wang, Huaibao

    2016-09-01

    At present, increasingly more proton medical facilities have been established globally for better curative effect and less side effect in tumor treatment. Compared with electron and photon, proton delivers more energy and dose at its end of range (Bragg peak), and has less lateral scattering for its much larger mass. However, proton is much easier to produce neutron and induced radioactivity, which makes radiation protection for proton accelerators more difficult than for electron accelerators. This study focuses on the problem of patient-induced radioactivity during proton treatment, which has been ignored for years. However, we confirmed it is a vital factor for radiation protection to both patient escort and positioning technician, by FLUKA's simulation and activation formula calculation of Hengjian Proton Medical Facility (HJPMF), whose energy ranges from 130 to 230MeV. Furthermore, new formulas for calculating the activity buildup process of periodic irradiation were derived and used to study the relationship between saturation degree and half-life of nuclides. Finally, suggestions are put forward to lessen the radiation hazard from patient-induced radioactivity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Status of the Center for Advanced Microstructures and Devices (CAMD)—2010

    NASA Astrophysics Data System (ADS)

    Roy, Amitava; Morikawa, Eizi; Bellamy, Henry; Kumar, Challa; Goettert, Jost; Suller, Victor; Morris, Kevin; Kurtz, Richard; Scott, John

    2011-09-01

    The J. Bennett Johnston, Sr., Center for Advanced Microstructures and Devices (CAMD) is a 1.3 GeV synchrotron-radiation facility owned and operated by the State of Louisiana. Fifteen beamlines provide radiation for CAMD users and cover the spectral range from the far IR to X-rays of ca. 40 keV. Eleven of them receive radiation from bending magnets and four from a 7 T wavelength shifter. A wide range of basic and applied scientific experiments as well as microfabrication are performed at these beamlines. The nanomaterial synthesis and characterization laboratory at CAMD continues to add new instruments such as SQUID magnetometer (Quantum Deign MPMS XL5) and high precision microfluidic-based nanomaterials synthesis equipment complementing already available facilities. We have recently received NSF MRI funding for a multipole 7.5 T wiggler that will become operational in 2012. Generous equipment donations from the University of California at Riverside (Professor Jory Yarmoff) and the University of Bonn (ELSA facility) will provide users with two additional VUV beamlines in the near future.

  8. The RaDIATE High-Energy Proton Materials Irradiation Experiment at the Brookhaven Linac Isotope Producer Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ammigan, Kavin; et al.

    The RaDIATE collaboration (Radiation Damage In Accelerator Target Environments) was founded in 2012 to bring together the high-energy accelerator target and nuclear materials communities to address the challenging issue of radiation damage effects in beam-intercepting materials. Success of current and future high intensity accelerator target facilities requires a fundamental understanding of these effects including measurement of materials property data. Toward this goal, the RaDIATE collaboration organized and carried out a materials irradiation run at the Brookhaven Linac Isotope Producer facility (BLIP). The experiment utilized a 181 MeV proton beam to irradiate several capsules, each containing many candidate material samples formore » various accelerator components. Materials included various grades/alloys of beryllium, graphite, silicon, iridium, titanium, TZM, CuCrZr, and aluminum. Attainable peak damage from an 8-week irradiation run ranges from 0.03 DPA (Be) to 7 DPA (Ir). Helium production is expected to range from 5 appm/DPA (Ir) to 3,000 appm/DPA (Be). The motivation, experimental parameters, as well as the post-irradiation examination plans of this experiment are described.« less

  9. ARC-2006-ACD06-0177-016

    NASA Image and Video Library

    2006-10-10

    CEV (Crew Escape Vehicle) capsule Balistic Range testing to examine static and dynamic stability characteristics (at the Hypervelocity Free-Flight Facility) HFF - Don Holt installing projectile & powder charge

  10. ARC-2006-ACD06-0177-010

    NASA Image and Video Library

    2006-10-10

    CEV (Crew Escape Vehicle) capsule Balistic Range testing to examine static and dynamic stability characteristics (at the Hypervelocity Free-Flight Facility) HFF Chuck Cornelison operating 'Firing' control pannel

  11. Rapid assessment of infrastructure of primary health care facilities - a relevant instrument for health care systems management.

    PubMed

    Scholz, Stefan; Ngoli, Baltazar; Flessa, Steffen

    2015-05-01

    Health care infrastructure constitutes a major component of the structural quality of a health system. Infrastructural deficiencies of health services are reported in literature and research. A number of instruments exist for the assessment of infrastructure. However, no easy-to-use instruments to assess health facility infrastructure in developing countries are available. Present tools are not applicable for a rapid assessment by health facility staff. Therefore, health information systems lack data on facility infrastructure. A rapid assessment tool for the infrastructure of primary health care facilities was developed by the authors and pilot-tested in Tanzania. The tool measures the quality of all infrastructural components comprehensively and with high standardization. Ratings use a 2-1-0 scheme which is frequently used in Tanzanian health care services. Infrastructural indicators and indices are obtained from the assessment and serve for reporting and tracing of interventions. The tool was pilot-tested in Tanga Region (Tanzania). The pilot test covered seven primary care facilities in the range between dispensary and district hospital. The assessment encompassed the facilities as entities as well as 42 facility buildings and 80 pieces of technical medical equipment. A full assessment of facility infrastructure was undertaken by health care professionals while the rapid assessment was performed by facility staff. Serious infrastructural deficiencies were revealed. The rapid assessment tool proved a reliable instrument of routine data collection by health facility staff. The authors recommend integrating the rapid assessment tool in the health information systems of developing countries. Health authorities in a decentralized health system are thus enabled to detect infrastructural deficiencies and trace the effects of interventions. The tool can lay the data foundation for district facility infrastructure management.

  12. Timeliness of abnormal screening and diagnostic mammography follow-up at facilities serving vulnerable women

    PubMed Central

    Goldman, L. Elizabeth; Walker, Rod; Hubbard, Rebecca; Kerlikowske, Karla

    2013-01-01

    Background Whether timeliness of follow-up after abnormal mammography differs at facilities serving vulnerable populations such as women with limited education or income, in rural areas, and racial/ethnic minorities is unknown. Methods We examined receipt of diagnostic evaluation following abnormal mammography using 1998-2006 Breast Cancer Surveillance Consortium-linked Medicare claims. We compared whether time to recommended breast imaging or biopsy depended on whether women attended facilities serving vulnerable populations. We characterized a facility by the proportion of mammograms performed on women with limited education or income, in rural areas, or racial/ethnic minorities. Results We analyzed 30,874 abnormal screening examinations recommended for follow-up imaging across 142 facilities and 10,049 abnormal diagnostic examinations recommended for biopsy across 114 facilities. Women at facilities serving populations with less education or more racial/ethnic minorities had lower rates of follow-up imaging (4-5% difference, p<0.05), and women at facilities serving more rural and low income populations had lower rates of biopsy (4-5% difference, p<0.05). Women undergoing biopsy at facilities serving vulnerable populations had longer times until biopsy than those at facilities serving non-vulnerable populations (21.6 days vs. 15.6 days; 95% CI for mean difference 4.1-7.7). The proportion of women receiving recommended imaging within 11 months and biopsy within 3 months varied across facilities (interquartile range 85.5%-96.5% for imaging and 79.4%-87.3% for biopsy). Conclusions Among Medicare recipients, follow-up rates were slightly lower at facilities serving vulnerable populations, and among those women who returned for diagnostic evaluation, time to follow-up was slightly longer at facilities that served vulnerable population. Interventions should target variability in follow-up rates across facilities, and evaluate effectiveness particularly at facilities serving vulnerable populations. PMID:23358386

  13. ARC-2006-ACD06-0177-008

    NASA Image and Video Library

    2006-10-10

    CEV (Crew Escape Vehicle) capsule Balistic Range testing to examine static and dynamic stability characteristics (at the Hypervelocity Free-Flight Facility) HFF - Bon Bowling machining sabot to find dimensions

  14. The Marshall Space Flight Center Low-Energy Ion Facility: A preliminary report

    NASA Technical Reports Server (NTRS)

    Biddle, A. P.; Reynolds, J. W.; Chisholm, W. L., Jr.; Hunt, R. D.

    1983-01-01

    The Low-Energy Ion Facility (LEIF) is designed for laboratory research of low-energy ion beams similar to those present in the magnetosphere. In addition, it provides the ability to develop and calibrate low-energy, less than 50 eV, plasma instrumentation over its full range of energy, mass, flux, and arrival angle. The current status of this evolving resource is described. It also provides necessary information to allow users to utilize it most efficiently.

  15. Common Risk Criteria Standards for National Test Ranges

    DTIC Science & Technology

    2017-09-01

    critical assets. Equipment and facilities that comprise part of an on- or off-base renewable energy system, such as wind turbine generation facilities...to be protected. As an example, for a wind turbine farm, the unit component would be a single wind turbine . A unit component can be considered...functionality of the larger system to which the unit component belongs. For example, a single wind turbine is a unit component of a wind turbine farm. A

  16. The NIF x-ray spectrometer calibration campaign at Omega.

    PubMed

    Pérez, F; Kemp, G E; Regan, S P; Barrios, M A; Pino, J; Scott, H; Ayers, S; Chen, H; Emig, J; Colvin, J D; Bedzyk, M; Shoup, M J; Agliata, A; Yaakobi, B; Marshall, F J; Hamilton, R A; Jaquez, J; Farrell, M; Nikroo, A; Fournier, K B

    2014-11-01

    The calibration campaign of the National Ignition Facility X-ray Spectrometer (NXS) was carried out at the Omega laser facility. Spherically symmetric, laser-driven, millimeter-scale x-ray sources of K-shell and L-shell emission from various mid-Z elements were designed for the 2-18 keV energy range of the NXS. The absolute spectral brightness was measured by two calibrated spectrometers. We compare the measured performance of the target design to radiation hydrodynamics simulations.

  17. Vice President Mike Pence Visits Kennedy Space Center - Tour of

    NASA Image and Video Library

    2018-02-21

    Vice President Mike Pence signs a banner during a tour of the Boeing Commercial Crew and Cargo Processing Facility at NASA's Kennedy Space Center in Florida, on Feb. 21, 2018. During his visit, Pence chaired a meeting of the National Space Council in the high bay of the center's Space Station Processing Facility. The council's role is to advise the president regarding national space policy and strategy, and review the nation's long-range goals for space activities.

  18. Impact cratering in reduced-gravity environments: Early experiments on the NASA KC-135 aircraft

    NASA Technical Reports Server (NTRS)

    Cintala, Mark J.; Hoerz, F.; See, T. H.

    1987-01-01

    Impact experimentation on the NASA KC-135 Reduced-Gravity Aircraft was shown to be possible, practical, and of considerable potential use in examining the role of gravity on various impact phenomena. With a minimal facility, crater dimensional and growth-times were measured, and have demonstrated both agreement and disagreement with predictions. A larger facility with vacuum capability and a high-velocity gun would permit a much wider range of experimentation.

  19. Simbol-X: Synergies with JWST, ALMA and Herschel

    NASA Astrophysics Data System (ADS)

    Maiolino, R.

    2009-05-01

    I discuss the synergies between Simbol-X and three among the major astronomical facilities that, in the next decade, will be operative in the infrared-millimeter spectral range, namely JWST, Herschel and ALMA. I first provide a brief overview of the main features and observing capabilities offered by these facilities. Then I will discuss a few research fields (mostly extragalactic) that will geatly benefit of the joint exploitation of Simbol-X and these IR-mm observatories.

  20. Cost comparison of full-scale water reclamation technologies with an emphasis on membrane bioreactors.

    PubMed

    Iglesias, Raquel; Simón, Pedro; Moragas, Lucas; Arce, Augusto; Rodriguez-Roda, Ignasi

    2017-06-01

    The paper assesses the costs of full-scale membrane bioreactors (MBRs). Capital expenditures (CAPEX) and operating expenses (OPEX) of Spanish MBR facilities have been verified and compared to activated sludge plants (CAS) using water reclamation treatment (both conventional and advanced). Spanish MBR facilities require a production of 0.6 to 1.2 kWh per m 3 , while extended aeration (EA) and advanced reclamation treatment require 1.2 kWh per m 3 . The energy represents around 40% of the OPEX in MBRs. In terms of CAPEX, the implementation costs of a CAS facility followed by conventional water reclamation treatment (physical-chemical + sand filtration + disinfection) ranged from 730 to 850 €.m -3 d, and from 1,050 to 1,250 €.m -3 d in the case of advanced reclamation treatment facilities (membrane filtration) with a capacity of 8,000 to 15,000 m 3 d -1 . The MBR cost for similar capacities ranges between 700 and 960 €.m -3 d. This study shows that MBRs that have been recently installed represent a cost competitive option for water reuse applications for medium and large capacities (over 10,000 m 3 d -1 ), with similar OPEX to EA and conventional water reclamation treatment. In terms of CAPEX, MBRs are cheaper than EA, followed by advanced water reclamation treatment.

  1. Use of a spatial scan statistic to identify clusters of births occurring outside Ghanaian health facilities for targeted intervention.

    PubMed

    Bosomprah, Samuel; Dotse-Gborgbortsi, Winfred; Aboagye, Patrick; Matthews, Zoe

    2016-11-01

    To identify and evaluate clusters of births that occurred outside health facilities in Ghana for targeted intervention. A retrospective study was conducted using a convenience sample of live births registered in Ghanaian health facilities from January 1 to December 31, 2014. Data were extracted from the district health information system. A spatial scan statistic was used to investigate clusters of home births through a discrete Poisson probability model. Scanning with a circular spatial window was conducted only for clusters with high rates of such deliveries. The district was used as the geographic unit of analysis. The likelihood P value was estimated using Monte Carlo simulations. Ten statistically significant clusters with a high rate of home birth were identified. The relative risks ranged from 1.43 ("least likely" cluster; P=0.001) to 1.95 ("most likely" cluster; P=0.001). The relative risks of the top five "most likely" clusters ranged from 1.68 to 1.95; these clusters were located in Ashanti, Brong Ahafo, and the Western, Eastern, and Greater regions of Accra. Health facility records, geospatial techniques, and geographic information systems provided locally relevant information to assist policy makers in delivering targeted interventions to small geographic areas. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  2. Occurrence of antibiotics in wastewater treatment facilities in Wisconsin, USA

    USGS Publications Warehouse

    Karthikeyan, K.G.; Meyer, M.T.

    2006-01-01

    Samples from several wastewater treatment facilities in Wisconsin were screened for the presence of 21 antibiotic compounds. These facilities spanned a range of community size served (average daily flow from 0.0212 to 23.6 million gallons/day), secondary treatment processes, geographic locations across the state, and they discharged the treated effluents to both surface and ground waters (for ground water after a soil passage). A total of six antibiotic compounds were detected (1-5 compounds per site), including two sulfonamides (sulfamethazine, sulfamethoxazole), one tetracycline (tetracycline), fluoroquinolone (ciprofloxacin), macrolide (erythromycin-H2O) and trimethoprim. The frequency of detection of antibiotics was in the following order: tetracycline and trimethoprim (80%) > sulfamethoxazole (70%) > erythromycin-H2O (45%) > ciprofloxacin (40%) > sulfamethazine (10%). However, the soluble concentrations were in the parts-per-billion (ppb) range (??? 1.3 ??g/L), and importantly were unaffected by the size of the wastewater treatment facility. The concentrations detected were within an order of magnitude of those reported for similar systems in Europe and Canada: they were within a factor of two in comparison to those reported for Canada but generally lower relative to those measured in wastewater systems in Europe. Only sulfamethoxazole and tetracycline were detected in groundwater monitoring wells adjacent to the treatment systems. Future intensive wastewater monitoring programs in Wisconsin may be limited to the six antibiotic compounds detected in this study. ?? 2005 Elsevier B.V. All rights reserved.

  3. Occurrence of antibiotics in wastewater treatment facilities in Wisconsin, USA.

    PubMed

    Karthikeyan, K G; Meyer, Michael T

    2006-05-15

    Samples from several wastewater treatment facilities in Wisconsin were screened for the presence of 21 antibiotic compounds. These facilities spanned a range of community size served (average daily flow from 0.0212 to 23.6 million gallons/day), secondary treatment processes, geographic locations across the state, and they discharged the treated effluents to both surface and ground waters (for ground water after a soil passage). A total of six antibiotic compounds were detected (1-5 compounds per site), including two sulfonamides (sulfamethazine, sulfamethoxazole), one tetracycline (tetracycline), fluoroquinolone (ciprofloxacin), macrolide (erythromycin-H(2)O) and trimethoprim. The frequency of detection of antibiotics was in the following order: tetracycline and trimethoprim (80%)>sulfamethoxazole (70%)>erythromycin-H(2)O (45%)>ciprofloxacin (40%)>sulfamethazine (10%). However, the soluble concentrations were in the parts-per-billion (ppb) range (

  4. Santa Rita Experimental Range digital database: user's guide

    Treesearch

    Mitchel P. McClaran; Deborah L. Angell; Craig Wissler

    2002-01-01

    Long-term measurements and repeat photograph collections have been collected in a systematic manner on the approximately 21,000 ha Santa Rita Experimental Range (SRER) since its establishment in 1903. This research facility, located in the Desert Grassland vegetation of southern Arizona, was administered by the U.S. Department of Agriculture until 1988, when it was...

  5. Development of a Radio Frequency Space Environment Path Emulator for Evaluating Spacecraft Ranging Hardware

    NASA Technical Reports Server (NTRS)

    Mitchell, Jason W.; Baldwin, Philip J.; Kurichh, Rishi; Naasz, Bo J.; Luquette, Richard J.

    2007-01-01

    The Formation Flying Testbed (FFTB) at the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) provides a hardware-in-the-loop test environment for formation navigation and control. The facility is evolving as a modular, hybrid, dynamic simulation facility for end-to-end guidance, navigation and. control (GN&C) design and analysis of formation flying spacecraft. The core capabilities of the FFTB, as a platform for testing critical hardware and software algorithms in-the-loop, have expanded to include S-band Radio Frequency (RF) modems for inter-spacecraft communication and ranging. To enable realistic simulations that require RF ranging sensors for relative navigation, a mechanism is needed to buffer the RF signals exchanged between spacecraft that accurately emulates the dynamic environment through which the RF signals travel, including the effects of medium, moving platforms, and radiated power. The Path Emulator for RF Signals (PERFS), currently under development at NASA GSFC, provides this capability. The function and performance of a prototype device are presented.

  6. Characterization of a Prototype Radio Frequency Space Environment Path Emulator for Evaluating Spacecraft Ranging Hardware

    NASA Technical Reports Server (NTRS)

    Mitchell, Jason W.; Baldwin, Philip J.; Kurichh, Rishi; Naasz, Bo J.; Luquette, Richard J.

    2007-01-01

    The Formation Flying Testbed (FFTB) at the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) provides a hardware-in-the-loop test environment for formation navigation and control. The facility is evolving as a modular, hybrid, dynamic simulation facility for end-to-end guidance, navigation and control (GN&C) design and analysis of formation flying spacecraft. The core capabilities of the FFTB, as a platform for testing critical hardware and software algorithms in-the-loop, have expanded to include S-band Radio Frequency (RF) modems for interspacecraft communication and ranging. To enable realistic simulations that require RF ranging sensors for relative navigation, a mechanism is needed to buffer the RF signals exchanged between spacecraft that accurately emulates the dynamic environment through which the RF signals travel, including the effects of the medium, moving platforms, and radiated power. The Path Emulator for Radio Frequency Signals (PERFS), currently under development at NASA GSFC, provides this capability. The function and performance of a prototype device are presented.

  7. A compact proton spectrometer for measurement of the absolute DD proton spectrum from which yield and ρR are determined in thin-shell inertial-confinement-fusion implosions.

    PubMed

    Rosenberg, M J; Zylstra, A B; Frenje, J A; Rinderknecht, H G; Johnson, M Gatu; Waugh, C J; Séguin, F H; Sio, H; Sinenian, N; Li, C K; Petrasso, R D; Glebov, V Yu; Hohenberger, M; Stoeckl, C; Sangster, T C; Yeamans, C B; LePape, S; Mackinnon, A J; Bionta, R M; Talison, B; Casey, D T; Landen, O L; Moran, M J; Zacharias, R A; Kilkenny, J D; Nikroo, A

    2014-10-01

    A compact, step range filter proton spectrometer has been developed for the measurement of the absolute DD proton spectrum, from which yield and areal density (ρR) are inferred for deuterium-filled thin-shell inertial confinement fusion implosions. This spectrometer, which is based on tantalum step-range filters, is sensitive to protons in the energy range 1-9 MeV and can be used to measure proton spectra at mean energies of ∼1-3 MeV. It has been developed and implemented using a linear accelerator and applied to experiments at the OMEGA laser facility and the National Ignition Facility (NIF). Modeling of the proton slowing in the filters is necessary to construct the spectrum, and the yield and energy uncertainties are ±<10% in yield and ±120 keV, respectively. This spectrometer can be used for in situ calibration of DD-neutron yield diagnostics at the NIF.

  8. X-ray grating spectrometer for opacity measurements in the 50 eV to 250 eV spectral range at the LULI 2000 laser facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reverdin, Charles; Caillaud, T.; Gilleron, F.

    2012-10-15

    An x-ray grating spectrometer was built in order to measure opacities in the 50 eV to 250 eV spectral range with an average spectral resolution {approx} 50. It has been used at the LULI-2000 laser facility at Ecole Polytechnique (France) to measure the {Delta}n = 0, n = 3 transitions of several elements with neighboring atomic number: Cr, Fe, Ni, and Cu in the same experimental conditions. Hence a spectrometer with a wide spectral range is required. This spectrometer features one line of sight looking through a heated sample at backlighter emission. It is outfitted with one toroidal condensing mirrormore » and several flat mirrors cutting off higher energy photons. The spectral dispersion is obtained with a flatfield grating. Detection consists of a streak camera sensitive to soft x-ray radiation. Some experimental results showing the performance of this spectrometer are presented.« less

  9. X-ray grating spectrometer for opacity measurements in the 50 eV to 250 eV spectral range at the LULI 2000 laser facility.

    PubMed

    Reverdin, Charles; Thais, Frédéric; Loisel, Guillaume; Busquet, M; Bastiani-Ceccotti, S; Blenski, T; Caillaud, T; Ducret, J E; Foelsner, W; Gilles, D; Gilleron, F; Pain, J C; Poirier, M; Serres, F; Silvert, V; Soullie, G; Turck-Chieze, S; Villette, B

    2012-10-01

    An x-ray grating spectrometer was built in order to measure opacities in the 50 eV to 250 eV spectral range with an average spectral resolution ∼ 50. It has been used at the LULI-2000 laser facility at École Polytechnique (France) to measure the Δn = 0, n = 3 transitions of several elements with neighboring atomic number: Cr, Fe, Ni, and Cu in the same experimental conditions. Hence a spectrometer with a wide spectral range is required. This spectrometer features one line of sight looking through a heated sample at backlighter emission. It is outfitted with one toroidal condensing mirror and several flat mirrors cutting off higher energy photons. The spectral dispersion is obtained with a flatfield grating. Detection consists of a streak camera sensitive to soft x-ray radiation. Some experimental results showing the performance of this spectrometer are presented.

  10. A compact proton spectrometer for measurement of the absolute DD proton spectrum from which yield and pR are determined in thin-shell inertial-confinement-fusion implosions

    DOE PAGES

    Rosenberg, M. J.; Zylstra, A. B.; Frenje, J. A.; ...

    2014-10-10

    A compact, step range filter proton spectrometer has been developed for the measurement of the absolute DD proton spectrum, from which yield and areal density (ρR) are inferred for deuterium-filled thin-shell inertial confinement fusion implosions. This spectrometer, which is based on tantalum step-range filters, is sensitive to protons in the energy range 1-9 MeV and can be used to measure proton spectra at mean energies of ~1-3 MeV. It has been developed and implemented using a linear accelerator and applied to experiments at the OMEGA laser facility and the National Ignition Facility (NIF). Modeling of the proton slowing in themore » filters is necessary to construct the spectrum, and the yield and energy uncertainties are ±<10% in yield and ±120 keV, respectively. This spectrometer can be used for in situ calibration of DD-neutron yield diagnostics at the NIF« less

  11. A compact proton spectrometer for measurement of the absolute DD proton spectrum from which yield and ρR are determined in thin-shell inertial-confinement-fusion implosions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, M. J., E-mail: mrosenbe@mit.edu; Zylstra, A. B.; Frenje, J. A.

    2014-10-01

    A compact, step range filter proton spectrometer has been developed for the measurement of the absolute DD proton spectrum, from which yield and areal density (ρR) are inferred for deuterium-filled thin-shell inertial confinement fusion implosions. This spectrometer, which is based on tantalum step-range filters, is sensitive to protons in the energy range 1-9 MeV and can be used to measure proton spectra at mean energies of ~1-3 MeV. It has been developed and implemented using a linear accelerator and applied to experiments at the OMEGA laser facility and the National Ignition Facility (NIF). Modeling of the proton slowing in themore » filters is necessary to construct the spectrum, and the yield and energy uncertainties are ±<10% in yield and ±120 keV, respectively. This spectrometer can be used for in situ calibration of DD-neutron yield diagnostics at the NIF.« less

  12. A technique for extending by ~10 3 the dynamic range of compact proton spectrometers for diagnosing ICF implosions on the National Ignition Facility and OMEGA a)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sio, H.; Séguin, F. H.; Frenje, J. A.

    Wedge Range Filter (WRF) proton spectrometers are routinely used on OMEGA and the NIF for diagnosing ρR and ρR asymmetries in direct- and indirect-drive implosions of D 3He-, D 2-, and DT-gas-filled capsules. By measuring the optical opacity distribution in CR-39 due to proton tracks in high-yield applications, as opposed to counting individual tracks, WRF dynamic range can be extended by 10 2 for obtaining the spectral shape, and by 10 3 for mean energy (ρR) measurement, corresponding to proton fluences of 10 8 and 10 9 cm -2, respectively. Finally, using this new technique, ρR asymmetries can be measuredmore » during both shock and compression burn (proton yield ~10 8 and ~10 12, respectively) in 2-shock National Ignition Facility implosions with the standard WRF accuracy of ±~10 mg/cm 2.« less

  13. 8-Channel Broadband Laser Ranging Hardware Development

    NASA Astrophysics Data System (ADS)

    Bennett, Corey; La Lone, Brandon; Younk, Patrick; Daykin, Ed; Rhodes, Michelle; Perry, Daniel; Tran, Vu; Miller, Edward

    2017-06-01

    Broadband Laser Ranging (BLR) is a new diagnostic being developed to precisely measure the position vs. time of surfaces, shock break out, particle clouds, jets, and debris moving at kilometers per second speeds. The instrument uses interferometry to encode distance into a modulation in the spectrum of pulses from a mode-locked fiber laser and uses a dispersive Fourier transformation to map the spectral modulation into time. Range information is thereby recorded on a fast oscilloscope at the repetition rate of the laser, approximately every 50 ns. Current R&D is focused on developing a compact 8-channel system utilizing one laser and one high-speed oscilloscope. This talk will emphasize the hardware being developed for applications at the Contained Firing Facility at LLNL, but has a common architecture being developed in collaboration with NSTec and LANL for applications at multiple other facilities. Prepared by LLNL under Contract DE-AC52-07NA27344, by LANL under Contract DE-AC52-06NA25396, and by NSTec Contract DE-AC52-06NA25946.

  14. Instrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facility.

    PubMed

    Caresana, Marco; Helmecke, Manuela; Kubancak, Jan; Manessi, Giacomo Paolo; Ott, Klaus; Scherpelz, Robert; Silari, Marco

    2014-10-01

    This paper discusses an intercomparison campaign performed in the mixed radiation field at the CERN-EU (CERF) reference field facility. Various instruments were employed: conventional and extended-range rem counters including a novel instrument called LUPIN, a bubble detector using an active counting system (ABC 1260) and two tissue-equivalent proportional counters (TEPCs). The results show that the extended range instruments agree well within their uncertainties and within 1σ with the H*(10) FLUKA value. The conventional rem counters are in good agreement within their uncertainties and underestimate H*(10) as measured by the extended range instruments and as predicted by FLUKA. The TEPCs slightly overestimate the FLUKA value but they are anyhow consistent with it when taking the comparatively large total uncertainties into account, and indicate that the non-neutron part of the stray field accounts for ∼30 % of the total H*(10). © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Improved accuracy in ground-based facilities - Development of an automated film-reading system for ballistic ranges

    NASA Technical Reports Server (NTRS)

    Yates, Leslie A.

    1992-01-01

    Software for an automated film-reading system that uses personal computers and digitized shadowgraphs is described. The software identifies pixels associated with fiducial-line and model images, and least-squares procedures are used to calculate the positions and orientations of the images. Automated position and orientation readings for sphere and cone models are compared to those obtained using a manual film reader. When facility calibration errors are removed from these readings, the accuracy of the automated readings is better than the pixel resolution, and it is equal to, or better than, the manual readings. The effects of film-reading and facility-calibration errors on calculated aerodynamic coefficients is discussed.

  16. Design summary of a geostationary facility utilized as a communications platform

    NASA Technical Reports Server (NTRS)

    Barberis, N. J.; Brown, J. V.

    1986-01-01

    This paper describes the technical aspects of a geostationary platform facility that makes maximum use of the planned NASA space station and its elements, mainly the orbital maneuvering vehicle (OMV) and the orbital transfer vehicles (OTV). The platform design concept is described, with emphasis on the key technologies utilized to configure the platform. Key systems aspects include a design summary with discussion of the controls, telemetry, command and ranging, power, propulsion, control electronics, thermal control subsystems, and space station interfaces. The use of the facility as a communications platform is developed to demonstrate the attractiveness of the concept. The economic benefits are discussed, as well as the concept of servicing for payload upgrade.

  17. Spectral emissivity and transmissivity measurement for zinc sulphide infrared window based on integrating-sphere reflectometry

    NASA Astrophysics Data System (ADS)

    Zhang, Yu-Feng; Dai, Jing-Min; Zhang, Lei; Pan, Wei-Dong

    2013-08-01

    The spectral emissivity and transmissivity of zinc sulphide (ZnS) infrared windows in the spectral region from 2 to 12 μm and temperature range from 20 to 700°C is measured by a facility built at the Harbin Institute of Technology (HIT). The facility is based on the integrating-sphere reflectometry. Measurements have been performed on two samples made of ZnS. The results measured at 20°C are in good agreement with those obtained by the method of radiant energy comparison using a Fourier transform infrared spectrometer. Emissivity measurements performed with this facility present an uncertainty of 5.5% (cover factor=2).

  18. NASA Lighting Research, Test, & Analysis

    NASA Technical Reports Server (NTRS)

    Clark, Toni

    2015-01-01

    The Habitability and Human Factors Branch, at Johnson Space Center, in Houston, TX, provides technical guidance for the development of spaceflight lighting requirements, verification of light system performance, analysis of integrated environmental lighting systems, and research of lighting-related human performance issues. The Habitability & Human Factors Lighting Team maintains two physical facilities that are integrated to provide support. The Lighting Environment Test Facility (LETF) provides a controlled darkroom environment for physical verification of lighting systems with photometric and spetrographic measurement systems. The Graphics Research & Analysis Facility (GRAF) maintains the capability for computer-based analysis of operational lighting environments. The combined capabilities of the Lighting Team at Johnson Space Center have been used for a wide range of lighting-related issues.

  19. Development and use of interactive displays in real-time ground support research facilities

    NASA Technical Reports Server (NTRS)

    Rhea, Donald C.; Hammons, Kvin R.; Malone, Jacqueline C.; Nesel, Michael C.

    1989-01-01

    The NASA Western Aeronautical Test Range (WATR) is one of the world's most advanced aeronautical research flight test support facilities. A variety of advanced and often unique real-time interactive displays has been developed for use in the mission control centers (MCC) to support research flight and ground testing. These dispalys consist of applications operating on systems described as real-time interactive graphics super workstations and real-time interactive PC/AT compatible workstations. This paper reviews these two types of workstations and the specific applications operating on each display system. The applications provide examples that demonstrate overall system capability applicable for use in other ground-based real-time research/test facilities.

  20. Assessment and Mitigation of Radiation, EMP, Debris & Shrapnel Impacts at Megajoule-Class Laser Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eder, D C; Anderson, R W; Bailey, D S

    2009-10-05

    The generation of neutron/gamma radiation, electromagnetic pulses (EMP), debris and shrapnel at mega-Joule class laser facilities (NIF and LMJ) impacts experiments conducted at these facilities. The complex 3D numerical codes used to assess these impacts range from an established code that required minor modifications (MCNP - calculates neutron and gamma radiation levels in complex geometries), through a code that required significant modifications to treat new phenomena (EMSolve - calculates EMP from electrons escaping from laser targets), to a new code, ALE-AMR, that is being developed through a joint collaboration between LLNL, CEA, and UC (UCSD, UCLA, and LBL) for debrismore » and shrapnel modelling.« less

  1. The Berkeley extreme ultraviolet calibration facility

    NASA Technical Reports Server (NTRS)

    Welsh, Barry Y.; Jelinsky, Patrick; Malina, Roger F.

    1988-01-01

    The vacuum calibration facilities of the Space Sciences Laboratory, University of California at Berkeley are designed for the calibration and testing of EUV and FUV spaceborne instrumentation (spectral range 44-2500 A). The facility includes one large cylindrical vacuum chamber (3 x 5 m) containing two EUV collimators, and it is equipped with a 4-axis manipulator of angular-control resolution 1 arcsec for payloads weighing up to 500 kg. In addition, two smaller cylindrical chambers, each 0.9 x 1.2 m, are available for vacuum and thermal testing of UV detectors, filters, and space electronics hardware. All three chambers open into class-10,000 clean rooms, and all calibrations are referred to NBS secondary standards.

  2. ARC-2006-ACD06-0177-012

    NASA Image and Video Library

    2006-10-04

    CEV (Crew Escape Vehicle) capsule Balistic Range testing to examine static and dynamic stability characteristics (at the Hypervelocity Free-Flight Facility) HFF - Chuck Cornelison viewing 8x10 shadowgraph images

  3. Laser-optical measurements of the velocities of the plasma jets formed from different gases in a kilojoule-range plasma focus facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Polukhin, S. N., E-mail: snpol@lebedev.ru; Dzhamankulov, A. M.; Gurei, A. E.

    The velocities of the plasma jets formed from Ne, N{sub 2}, Ar, and Xe gases in plasma focus facilities were determined by means of laser-optical shadowgraphy of the shock waves generated at the jet leading edge. In spite of the almost tenfold ratio between the atomic weights of these gases, the outflow velocities of the plasma jets formed in experiments with these gases differ by less than twice, in the range of (0.7–1.1) × 10{sup 7} cm/s under similar discharge conditions. The energies of the jet ions were found to vary from 0.7 keV for nitrogen to 4 keV formore » xenon.« less

  4. Advances in compact proton spectrometers for inertial-confinement fusion and plasma nuclear science.

    PubMed

    Seguin, F H; Sinenian, N; Rosenberg, M; Zylstra, A; Manuel, M J-E; Sio, H; Waugh, C; Rinderknecht, H G; Johnson, M Gatu; Frenje, J; Li, C K; Petrasso, R; Sangster, T C; Roberts, S

    2012-10-01

    Compact wedge-range-filter proton spectrometers cover proton energies ∼3-20 MeV. They have been used at the OMEGA laser facility for more than a decade for measuring spectra of primary D(3)He protons in D(3)He implosions, secondary D(3)He protons in DD implosions, and ablator protons in DT implosions; they are now being used also at the National Ignition Facility. The spectra are used to determine proton yields, shell areal density at shock-bang time and compression-bang time, fuel areal density, and implosion symmetry. There have been changes in fabrication and in analysis algorithms, resulting in a wider energy range, better accuracy and precision, and better robustness for survivability with indirect-drive inertial-confinement-fusion experiments.

  5. Capabilities and constraints of NASA's ground-based reduced gravity facilities

    NASA Technical Reports Server (NTRS)

    Lekan, Jack; Neumann, Eric S.; Sotos, Raymond G.

    1993-01-01

    The ground-based reduced gravity facilities of NASA have been utilized to support numerous investigations addressing various processes and phenomina in several disciplines for the past 30 years. These facilities, which include drop towers, drop tubes, aircraft, and sounding rockets are able to provide a low gravity environment (gravitational levels that range from 10(exp -2)g to 10(exp -6)g) by creating a free fall or semi-free fall condition where the force of gravity on an experiment is offset by its linear acceleration during the 'fall' (drop or parabola). The low gravity condition obtained on the ground is the same as that of an orbiting spacecraft which is in a state of perpetual free fall. The gravitational levels and associated duration times associated with the full spectrum of reduced gravity facilities including spaced-based facilities are summarized. Even though ground-based facilities offer a relatively short experiment time, this available test time has been found to be sufficient to advance the scientific understanding of many phenomena and to provide meaningful hardware tests during the flight experiment development process. Also, since experiments can be quickly repeated in these facilities, multistep phenomena that have longer characteristic times associated with them can sometimes be examined in a step-by-step process. There is a large body of literature which has reported the study results achieved through using reduced-gravity data obtained from the facilities.

  6. Safe, Cost Effective Management of Inactive Facilities at the Savannah River Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Austin, W. E.; Yannitell, D. M.; Freeman, D. W.

    The Savannah River Site is part of the U.S. Department of Energy complex. It was constructed during the early 1950s to produce basic materials (such as plutonium-239 and tritium) used in the production of nuclear weapons. The 310-square-mile site is located in South Carolina, about 12 miles south of Aiken, South Carolina, and about 15 miles southeast of Augusta, Georgia. Savannah River Site (SRS) has approximately 200 facilities identified as inactive. These facilities range in size and complexity from large nuclear reactors to small storage buildings. These facilities are located throughout the site including three reactor areas, the heavy watermore » plant area, the manufacturing area, and other research and support areas. Unlike DOE Closure Sites such as Hanford and Rocky Flats, SRS is a Project Completion Site with continuing missions. As facilities complete their defined mission, they are shutdown and transferred from operations to the facility disposition program. At the SRS, Facilities Decontamination and Decommissioning (FDD) personnel manage the disposition phase of a inactive facility's life cycle in a manner that minimizes life cycle cost without compromising (1) the health or safety of workers and the public or (2) the quality of the environment. The disposition phase begins upon completion of operations shutdown and extends through establishing the final end-state. FDD has developed innovative programs to manage their responsibilities within a constrained budget.« less

  7. Expanding Your Laboratory by Accessing Collaboratory Resources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoyt, David W.; Burton, Sarah D.; Peterson, Michael R.

    2004-03-01

    The Environmental Molecular Sciences Laboratory (EMSL) in Richland, Washington, is the home of a research facility setup by the United States Department of Energy (DOE). The facility is atypical because it houses over 100 cutting-edge research systems for the use of researchers all over the United States and the world. Access to the lab is requested through a peer-review proposal process and the scientists who use the facility are generally referred to as ‘users’. There are six main research facilities housed in EMSL, all of which host visiting researchers. Several of these facilities also participate in the EMSL Collaboratory, amore » remote access capability supported by EMSL operations funds. Of these, the High-Field Magnetic Resonance Facility (HFMRF) and Molecular Science Computing Facility (MSCF) have a significant number of their users performing remote work. The HFMRF in EMSL currently houses 12 NMR spectrometers that range in magnet field strength from 7.05T to 21.1T. Staff associated with the NMR facility offers scientific expertise in the areas of structural biology, solid-state materials/catalyst characterization, and magnetic resonance imaging (MRI) techniques. The way in which the HFMRF operates, with a high level of dedication to remote operation across the full suite of High-Field NMR spectrometers, has earned it the name “Virtual NMR Facility”. This review will focus on the operational aspects of remote research done in the High-Field Magnetic Resonance Facility and the computer tools that make remote experiments possible.« less

  8. Is the closest facility the one actually used? An assessment of travel time estimation based on mammography facilities.

    PubMed

    Alford-Teaster, Jennifer; Lange, Jane M; Hubbard, Rebecca A; Lee, Christoph I; Haas, Jennifer S; Shi, Xun; Carlos, Heather A; Henderson, Louise; Hill, Deirdre; Tosteson, Anna N A; Onega, Tracy

    2016-02-18

    Characterizing geographic access depends on a broad range of methods available to researchers and the healthcare context to which the method is applied. Globally, travel time is one frequently used measure of geographic access with known limitations associated with data availability. Specifically, due to lack of available utilization data, many travel time studies assume that patients use the closest facility. To examine this assumption, an example using mammography screening data, which is considered a geographically abundant health care service in the United States, is explored. This work makes an important methodological contribution to measuring access--which is a critical component of health care planning and equity almost everywhere. We analyzed one mammogram from each of 646,553 women participating in the US based Breast Cancer Surveillance Consortium for years 2005-2012. We geocoded each record to street level address data in order to calculate travel time to the closest and to the actually used mammography facility. Travel time between the closest and the actual facility used was explored by woman-level and facility characteristics. Only 35% of women in the study population used their closest facility, but nearly three-quarters of women not using their closest facility used a facility within 5 min of the closest facility. Individuals that by-passed the closest facility tended to live in an urban core, within higher income neighborhoods, or in areas where the average travel times to work was longer. Those living in small towns or isolated rural areas had longer closer and actual median drive times. Since the majority of US women accessed a facility within a few minutes of their closest facility this suggests that distance to the closest facility may serve as an adequate proxy for utilization studies of geographically abundant services like mammography in areas where the transportation networks are well established.

  9. Rating long-term care facilities on pressure ulcer development: importance of case-mix adjustment.

    PubMed

    Berlowitz, D R; Ash, A S; Brandeis, G H; Brand, H K; Halpern, J L; Moskowitz, M A

    1996-03-15

    To determine the importance of case-mix adjustment in interpreting differences in rates of pressure ulcer development in Department of Veterans Affairs long- term care facilities. A sample assembled from the Patient Assessment File, a Veterans Affairs administrative database, was used to derive predictors of pressure ulcer development; the resulting model was validated in a separate sample. Facility-level rates of pressure ulcer development, both unadjusted and adjusted for case mix using the predictive model, were compared. Department of Veterans Affairs long-term care facilities. The derivation sample consisted of 31 150 intermediate medicine and nursing home residents who were initially free of pressure ulcers and were institutionalized between October 1991 and April 1993. The validation sample consisted of 17 946 residents institutionalized from April 1993 to October 1993. Development of a stage 2 or greater pressure ulcer. 11 factors predicted pressure ulcer development. Validated performance properties of the resulting model were good. Model-predicted rates of pressure ulcer development at individual long-term care facilities varied from 1.9% to 6.3%, and observed rates ranged from 0% to 10.9%. Case-mix-adjusted rates and ranks of facilities differed considerably from unadjusted ratings. For example, among five facilities that were identified as high outliers on the basis of unadjusted rates, two remained as outliers after adjustment for case mix. Long-term care facilities differ in case mix. Adjustments for case mix result in different judgments about facility performance and should be used when facility incidence rates are compared.

  10. Availability and accessibility of subsidized mammogram screening program in peninsular Malaysia: A preliminary study using travel impedance approach

    PubMed Central

    Aljunid, Syed Mohamed

    2018-01-01

    Access to healthcare is essential in the pursuit of universal health coverage. Components of access are availability, accessibility (spatial and non-spatial), affordability and acceptability. Measuring spatial accessibility is common approach to evaluating access to health care. This study aimed to determine the availability and spatial accessibility of subsidised mammogram screening in Peninsular Malaysia. Availability was determined from the number and distribution of facilities. Spatial accessibility was determined using the travel impedance approach to represent the revealed access as opposed to potential access measured by other spatial measurement methods. The driving distance of return trips from the respondent’s residence to the facilities was determined using a mapping application. The travel expenditure was estimated by multiplying the total travel distance by a standardised travel allowance rate, plus parking fees. Respondents in this study were 344 breast cancer patients who received treatment at 4 referral hospitals between 2015 and 2016. In terms of availability, there were at least 6 major entities which provided subsidised mammogram programs. Facilities with mammogram involved with these programs were located more densely in the central and west coast region of the Peninsula. The ratio of mammogram facility to the target population of women aged 40–74 years ranged between 1: 10,000 and 1:80,000. In terms of accessibility, of the 3.6% of the respondents had undergone mammogram screening, their mean travel distance was 53.4 km (SD = 34.5, range 8–112 km) and the mean travel expenditure was RM 38.97 (SD = 24.00, range RM7.60–78.40). Among those who did not go for mammogram screening, the estimated travel distance and expenditure had a skewed distribution with median travel distance of 22.0 km (IQR 12.0, 42.0, range 2.0–340.0) and the median travel cost of RM 17.40 (IQR 10.40, 30.00, range 3.40–240.00). Higher travel impedance was noted among those who lived in sub-urban and rural areas. In summary, availability of mammogram facilities was good in the central and west coast of the peninsula. The overall provider-to-population ratio was lower than recommended. Based on the travel impedance approach used, accessibility to subsidised mammogram screening among the respondents was good in urban areas but deprived in other areas. This study was a preliminary study with limitations. Nonetheless, the evidence suggests that actions have to be taken to improve the accessibility to opportunistic mammogram screening in Malaysia in pursuit of universal health coverage. PMID:29389972

  11. 7 CFR 1735.17 - Facilities financed.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... more economically or technically feasible. Economic and technical feasibility will be determined using total long range economic costs and risk analysis. (d) Generally, RUS will not make a loan to another...

  12. ARC-2006-ACD06-0177-018

    NASA Image and Video Library

    2006-09-05

    CEV (Crew Escape Vehicle) capsule Balistic Range testing to examine static and dynamic stability characteristics (at the Hypervelocity Free-Flight Facility) HFF - scans of shadowgraphs from 8x10 film images

  13. ARC-2006-ACD06-0177-025

    NASA Image and Video Library

    2006-10-12

    CEV (Crew Escape Vehicle) capsule Balistic Range testing to examine static and dynamic stability characteristics (at the Hypervelocity Free-Flight Facility) HFF - scans of shadowgraphs from 8x10 film images

  14. ARC-2006-ACD06-0177-020

    NASA Image and Video Library

    2006-09-05

    CEV (Crew Escape Vehicle) capsule Balistic Range testing to examine static and dynamic stability characteristics (at the Hypervelocity Free-Flight Facility) HFF - scans of shadowgraphs from 8x10 film images

  15. ARC-2006-ACD06-0177-017

    NASA Image and Video Library

    2006-09-05

    CEV (Crew Escape Vehicle) capsule Balistic Range testing to examine static and dynamic stability characteristics (at the Hypervelocity Free-Flight Facility) HFF - scans of shadowgraphs from 8x10 film images

  16. ARC-2006-ACD06-0177-022

    NASA Image and Video Library

    2006-09-05

    CEV (Crew Escape Vehicle) capsule Balistic Range testing to examine static and dynamic stability characteristics (at the Hypervelocity Free-Flight Facility) HFF - scans of shadowgraphs from 8x10 film images

  17. 50th Anniversary Employee Picnic

    NASA Image and Video Library

    2011-10-08

    Nearly 500 Stennis Space Center employees and family members took part in the facility's 50th Anniversary Employee Picnic on Oct. 8. Participants enjoyed activities ranging from historical tours to sack races.

  18. Vitamin blood concentration and vitamin supplementation in bottlenose dolphins (Tursiops truncatus) in European facilities.

    PubMed

    Gimmel, Angela Emilia Ricarda; Baumgartner, Katrin; Liesegang, Annette

    2016-09-05

    As fish eaters bottlenose dolphins (Tursiops truncatus) in human care need to receive daily vitamin supplementation, because whole thawed fish lacks certain vitamins. However, the exact concentration of supplementation has not been established and is a matter of discussion. To ensure adequate vitamin supplementation in pets, vitamin blood concentrations are measured. This is not a common practice in dolphins. The objective of the present study was to collect information about vitamin supplementation in bottlenose dolphins and on vitamin blood concentrations of healthy animals in European facilities. In addition, these results were compared with blood levels of wild animals. Conclusions on how to provide bottlenose dolphins in human care with an effective vitamin supplementation will then be drawn. Initially, fish-handling techniques and vitamin supplementation were evaluated by questionnaire, which was sent to 25 European facilities that house bottlenose dolphins. Secondly, blood samples from 57 dolphins living in 10 facilities were taken and sent by mail to a reference laboratory. They were analysed for retinol, thiamine pyrophosphate, cobalamin, calcidiol and tocopherol. The blood concentrations were then correlated with vitamin supplementation, fish handling techniques and pre-existing blood concentrations of free-ranging dolphins. Finally, the data was subjected to a standard analysis of variance techniques (ANOVA) and a linear model analysis. Fish was mainly thawed in a refrigerator. Further, the 95 % confidence interval for retinol blood concentrations was 0.048 to 0.059 mg/l and for tocopherol 17.95 to 20.76 mg/l. These concentrations were 27 and 53 %, respectively, higher than those found in free-ranging animals. In contrast, calcidiol concentrations (143.9-174.7 ng/ml) of the dolphins in human care were lower than in blood found for free-ranging animals. Regarding thiamine pyrophosphate and cobalamin, concentrations ranged between 0.42 and 0.55 mg/l and 175.55 and 275.22 pg/ml respectively. No reference concentrations for free-ranging Tursiops truncatus were found. These findings suggest an over-supplementation of retinol (vitamin A) and tocopherol (vitamin E) in bottlenose dolphins (Tursiops truncatus) housed in human care. Therefore, vitamin A supplementation should not exceed 50,000 IU per animal per day and vitamin E supplementation should be around 100 IU per kg fed fish per day.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gündoğan, M. Tural, E-mail: mugetural@yahoo.com; Yavaş, Ö., E-mail: yavas@ankara.edu.tr; Kaya, Ç., E-mail: c.kaya@ankara.edu.tr

    Turkish Accelerator and Radiation Laboratory in Ankara (TARLA) facility is proposed as an IR FEL and Bremsstrahlung facility as the first facility of Turkish Accelerator Center (TAC). TARLA is essentially proposed to generate oscillator mode FEL in 3-250 microns wavelengths range, will consist of normal conducting injector system with 250 keV beam energy, two superconducting RF accelerating modules in order to accelerate the beam 15-40 MeV. The TARLA facility is expected to provide two modes, Continuous wave (CW) and pulsed mode. Longitudinal electron bunch length will be changed between 1 and 10 ps. The bunch charge will be limited by 77pC.more » The design of the Button-type Beam Position Monitor for TARLA IR FEL is studied to operate in 1.3 GHz. Mechanical antenna design and simulations are completed considering electron beam parameters of TARLA. Ansoft HFSS and CST Particle Studio is used to compare with results of simulations.« less

  20. Pure Air`s Bailly scrubber: A four-year retrospective

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manavi, G.B.; Vymazal, D.C.; Sarkus, T.A.

    1997-12-31

    Pure Air`s Advanced Flue Gas Desulfurization (AFGD) Clean Coal Project has completed four highly successful years of operation at NIPSCO`s Bailly Station. As part of their program, Pure Air has concluded a six-part study of system performance. This paper summarizes the results of the demonstration program, including AFGD performance on coals ranging from 2.0--2.4% sulfur. The paper highlights novel aspects of the Bailly facility, including pulverized limestone injection, air rotary sparger for oxidation, wastewater evaporation system and the production of PowerChip{reg_sign} gypsum. Operations and maintenance which have led to the facility`s notable 99.47% availability record are also discussed. A projectmore » company, Pure Air on the Lake Limited Partnership, owns the AFGD facility. Pure Air was the turn key contractor and Air Products and Chemicals, Inc. is the operator of the AFGD system.« less

  1. Neutral atoms facility for space sensors characterization and BepiColombo/ELENA development instrument's progresses.

    NASA Astrophysics Data System (ADS)

    de Angelis, E.; di Lellis, A. M.; Orsini, S.; Zanza, V.; Maggi, M.; Vertolli, N.; D'Amicis, R.; Tilia, B.; Sibio, A.

    2003-04-01

    An Energetic Neutral Atoms facility to test and calibrate Neutral Atoms Analyzers has been developed in the Scientific Technical Unit of Fusion at the ENEA Research Center in Frascati (Rome-Italy). In the last years a collaboration with IFSI (Interplanetary Space and Physics Institute, CNR-Rome-Italy) has allowed to use this facility for space sensors and for characterization of crucial instruments elements. The ENA beam is realized with an ion source and a neutralization cell, and allows to test any instrument in the energy range 300eV-110keV with the available masses of Hydrogen, Deuterium or Helium. At the moment, the critical elements of ELENA (Emitted Low Energy Neutral Atoms) instrument proposed for BepiColombo ESA cornerstone mission to Mercury is under development testing. The facility, its potentiality and the instrument characterization progresses are presented.

  2. Installation of a Low Flow Unit at the Abiquiu Hydroelectric Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jack Q. Richardson

    2012-06-28

    Final Technical Report for the Recovery Act Project for the Installation of a Low Flow Unit at the Abiquiu Hydroelectric Facility. The Abiquiu hydroelectric facility existed with two each 6.9 MW vertical flow Francis turbine-generators. This project installed a new 3.1 MW horizontal flow low flow turbine-generator. The total plant flow range to capture energy and generate power increased from between 250 and 1,300 cfs to between 75 and 1,550 cfs. Fifty full time equivalent (FTE) construction jobs were created for this project - 50% (or 25 FTE) were credited to ARRA funding due to the ARRA 50% project costmore » match. The Abiquiu facility has increased capacity, increased efficiency and provides for an improved aquatic environment owing to installed dissolved oxygen capabilities during traditional low flow periods in the Rio Chama. A new powerhouse addition was constructed to house the new turbine-generator equipment.« less

  3. On the viability of supporting institutional sharing of remote laboratory facilities

    NASA Astrophysics Data System (ADS)

    Lowe, David; Dang, Bridgette; Daniel, Keith; Murray, Stephen; Lindsay, Euan

    2015-11-01

    Laboratories are generally regarded as critical to engineering education, and yet educational institutions face significant challenges in developing and maintaining high-quality laboratory facilities. Remote laboratories are increasingly being explored as a partial solution to this challenge, with research showing that - for the right learning outcomes - they can be viable adjuncts or alternatives to conventional hands-on laboratories. One consequential opportunity arising from the inherent support for distributed access is the possibility of cross-institutional shared facilities. While both technical feasibility and pedagogic implications of remote laboratories have been well studied within the literature, the organisational and logistical issues associated with shared facilities have received limited consideration. This paper uses an existing national-scale laboratory sharing initiative, along with a related survey and laboratory sharing data, to analyse a range of factors that can affect engagement in laboratory sharing. The paper also discusses the implications for supporting ongoing laboratory sharing.

  4. Overview of Engineering Design and Analysis at the NASA John C. Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Ryan, Harry; Congiardo, Jared; Junell, Justin; Kirkpatrick, Richard

    2007-01-01

    A wide range of rocket propulsion test work occurs at the NASA John C. Stennis Space Center (SSC) including full-scale engine test activities at test facilities A-1, A-2, B-1 and B-2 as well as combustion device research and development activities at the E-Complex (E-1, E-2, E-3 and E-4) test facilities. The propulsion test engineer at NASA SSC faces many challenges associated with designing and operating a test facility due to the extreme operating conditions (e.g., cryogenic temperatures, high pressures) of the various system components and the uniqueness of many of the components and systems. The purpose of this paper is to briefly describe the NASA SSC Engineering Science Directorate s design and analysis processes, experience, and modeling techniques that are used to design and support the operation of unique rocket propulsion test facilities.

  5. New Environmental Testing Capabilities at INTA

    NASA Astrophysics Data System (ADS)

    Olivo, Esperanza; Hernandez, Daniel; Garranzo, Daniel; Barandiaran, Javier; Reina, Manuel

    2012-07-01

    In this paper we aim to present and describe the facilities for aerospace environmental testing at INTA; the Spanish National Institute for Aerospace Technique with emphasis on the Thermal Vacuum testing facility with dimensions 4 m x 4 m x 4 m and a temperature range from +150oC to -175 oC and 10-6 vacuum conditions with the new Thermo Elastic Distortion (TED) measurement capability designed at INTA. It will be presented the validation data for the empty chamber, with specimens such a 3m diameter reflector and antenna towers for both, thermal cycling and TED measurements. For TED, it will be shown the feasibility study and the solution finally selected. Apart from those, it will be shown other complementary facilities for environmental testing such as 320 (2x160) kN dual shaker with a new 3 m x 3 m sliding table and other complementary facilities.

  6. Case-mix and quality indicators in Chinese elder care homes: are there differences between government-owned and private-sector facilities?

    PubMed

    Liu, Chang; Feng, Zhanlian; Mor, Vincent

    2014-02-01

    To assess the association between ownership of Chinese elder care facilities and their performance quality and to compare the case-mix profile of residents and facility characteristics in government-owned and private-sector homes. Cross-sectional study. Census of elder care homes surveyed in Nanjing (2009) and Tianjin (2010). Elder care facilities located in urban Nanjing (n = 140, 95% of all) and urban Tianjin (n = 157, 97% of all). A summary case-mix index based on activity of daily living (ADL) limitations and cognitive impairment was created to measure levels of care needs of residents in each facility. Structure, process, and outcome measures were selected to assess facility-level quality of care. A structural quality measure, understaffing relative to resident levels of care needs, which indicates potentially inadequate staffing given resident case-mix, was also developed. Government-owned homes had significantly higher occupancy rates, presumably reflecting popular demand for publicly subsidized beds, but served residents who, on average, have fewer ADL and cognitive functioning limitations than those in private-sector facilities. Across a range of structure, process, and outcome measures of quality, there is no clear evidence suggesting advantages or disadvantages of either ownership type, although when staffing-to-resident ratio is gauged relative to resident case-mix, private-sector facilities were more likely to be understaffed than government-owned facilities. In Nanjing and Tianjin, private-sector homes were more likely to be understaffed, although their residents were sicker and frailer on average than those in government facilities. It is likely that the case-mix differences are the result of selective admission policies that favor healthier residents in government facilities than in private-sector homes. © 2014, Copyright the Authors Journal compilation © 2014, The American Geriatrics Society.

  7. Determinants of health system delay at public and private directly observed treatment, short course facilities in Lagos State, Nigeria: A cross-sectional study.

    PubMed

    Adejumo, Olusola Adedeji; Daniel, Olusoji James; Otesanya, Andrew Folarin; Adejumo, Esther Ngozi

    2016-09-01

    Despite several studies on health system delay (HSD) among tuberculosis (TB) patients in Nigeria, no study has compared HSD in private and public health facilities. This study assessed the determinants of HSD in public and private health facilities offering the directly observed treatment, short course (DOTS). A descriptive cross-sectional study was conducted. A total of 470 new smear-positive TB patients aged 14years and older were consecutively recruited between October 1, 2012, and December 31, 2012, from 34 (23 public and 11 private) DOTS facilities that offered treatment and microscopy services. Mann-Whitney U test and logistic regression were used to assess the determinants of HSD. The median HSD was longer at public DOTS facilities (14days; interquartile range [IQR] 10-21days) than private DOTS facilities (12.5days; IQR 10.0-14.0days, p=.002). Age and human immunodeficiency virus status were determinants of HSD at the public DOTS facilities, whereas sex and income were determinants of HSD at the private DOTS facilities. TB patients who first visited a nonhospital facility were over four times more likely (odds ratio 4.12; 95% confidence interval 2.25-7.54) to have prolonged HSD than those who first visited the government hospital when they first developed the symptoms of TB after controlling for other factors in the model. Determinants of HSD at the public and private DOTS facilities vary. Strategies to reduce HSD at both public and private DOTS facilities in Lagos State, Nigeria, are urgently needed. Copyright © 2016 Asian-African Society for Mycobacteriology. Published by Elsevier Ltd. All rights reserved.

  8. Selected meteorological data for an arid site near Beatty, Nye County, Nevada, calendar year 1988

    USGS Publications Warehouse

    Wood, James L.; Hill, Kevin J.; Andraski, Brian J.

    1992-01-01

    Selected meteorological data were collected at a study site adjacent to a low-level radioactive-waste burial facility near Beatty/ Nevada, for calendar year 1988. Data were collected in support of ongoing studies to estimate the potential for downward movement of radionuclides into the unsaturated sediments beneath waste-burial trenches at the facility. The data include air temperature, relative humidity, vapor pressure, incident solar radiation, windspeed, wind direction, and precipitation. The data are summarized in tables and graphs.Instrumentation used at the site is discussed. The discussion includes the type, reported accuracy, and mounting height of each sensor.In 1988, the average hourly air temperatures ranged from -10.2 degrees Celsius, in December, to 45.3 degrees Celsius, in July. Hourly averaged relative humidity ranged from about 12 percent to over 80 percent. Hourly vapor pressures ranged from 0.09 to 2.22 kilopascals. Daily values for maximum incident solar radiation ranged from 63 to 1,064 watts per square meter. Daily mean windspeed ranged from 1.2 to 7.8 meters per second. Monthly wind-direction patterns are shown in a series of diagrams in which wind direction is summed over 10-degree arcs from hourly averaged data. Total precipitation for 1988 was 104.5 millimeters, with over 70 percent occurring from January through May.

  9. Materials erosion and redeposition studies at the PISCES-facility: net erosion under redeposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirooka, Y.; Goebel, D.M.; Conn, R.W.

    1986-05-01

    Simultaneous erosion and redeposition of copper and 304 stainless steel under controlled and continuous plasma (D,He,Ar) bombardment has been investigated in the PISCES-facility, which generates typical edge-plasma conditions of magnetic fusion devices. The plasma bombardment conditions are: incident ion flux in the range from 10/sup 17/ to 10/sup 18/ ions/sec/cm/sup 2/, ion bombarding energy of 100 eV, electron temperature in the range from 5 to 15 eV, plasma density in the range from 10/sup 11/ to 10/sup 13/ cm/sup -3/, target temperature in the range from 300 to 900K, and the total ion fluence in the range from 10/sup 20/more » to 10/sup 22/ ions/cm/sup 2/. The net erosion yield under redeposition is found to be significantly smaller than the classical sputtering yield data. A first-order modeling is attempted to interpret the erosion and redeposition behavior of materials under plasma bombardment. It is pointed out both theoretically and experimentally that the mean free path for electron impact ionization of the sputtered material is the key parameter to control the overall mechanism of erosion and redeposition. Strongly modified surface morphologies of bombarded targets are observed and indicate a retrapping effect.« less

  10. Annual water-resources review, White Sands Missile Range: 1971

    USGS Publications Warehouse

    Cruz, R.R.

    1972-01-01

    This report presents water-resource information that was collected at White Sands Missile Range during 1971 and early 1972 by personnel of the U.S. Geological Survey, Water Resources Division. Data on ground-water pumpage and resulting water-level fluctuation, chemical quality, percipitation, and surface-water runoff are summarized in the report. The data were obtained as a result of the continuing water-resources basic-data collection program sponsored by the Facilities Engineering Directorate, White Sands Missile Range.

  11. Test Facilities and Experience on Space Nuclear System Developments at the Kurchatov Institute

    NASA Astrophysics Data System (ADS)

    Ponomarev-Stepnoi, Nikolai N.; Garin, Vladimir P.; Glushkov, Evgeny S.; Kompaniets, George V.; Kukharkin, Nikolai E.; Madeev, Vicktor G.; Papin, Vladimir K.; Polyakov, Dmitry N.; Stepennov, Boris S.; Tchuniyaev, Yevgeny I.; Tikhonov, Lev Ya.; Uksusov, Yevgeny I.

    2004-02-01

    The complexity of space fission systems and rigidity of requirement on minimization of weight and dimension characteristics along with the wish to decrease expenditures on their development demand implementation of experimental works which results shall be used in designing, safety substantiation, and licensing procedures. Experimental facilities are intended to solve the following tasks: obtainment of benchmark data for computer code validations, substantiation of design solutions when computational efforts are too expensive, quality control in a production process, and ``iron'' substantiation of criticality safety design solutions for licensing and public relations. The NARCISS and ISKRA critical facilities and unique ORM facility on shielding investigations at the operating OR nuclear research reactor were created in the Kurchatov Institute to solve the mentioned tasks. The range of activities performed at these facilities within the implementation of the previous Russian nuclear power system programs is briefly described in the paper. This experience shall be analyzed in terms of methodological approach to development of future space nuclear systems (this analysis is beyond this paper). Because of the availability of these facilities for experiments, the brief description of their critical assemblies and characteristics is given in this paper.

  12. Biomarkers of mercury exposure at a mercury recycling facility in Ukraine

    USGS Publications Warehouse

    Gibb, H.J.; Kozlov, K.; Buckley, J.P.; Centeno, J.; Jurgenson, V.; Kolker, A.; Conko, K.; Landa, E.; Panov, B.; Panov, Y.; Xu, H.

    2008-01-01

    This study evaluates biomarkers of occupational mercury exposure among workers at a mercury recycling operation in Gorlovka, Ukraine. The 29 study participants were divided into three occupational categories for analysis: (1) those who worked in the mercury recycling operation (Group A, n = 8), (2) those who worked at the facility but not in the yard where the recycling was done (Group B, n = 14), and (3) those who did not work at the facility (Group C, n = 7). Urine, blood, hair, and nail samples were collected from the participants, and a questionnaire was administered to obtain data on age, gender, occupational history, smoking, alcohol consumption, fish consumption, tattoos, dental amalgams, home heating system, education, source of drinking water, and family employment in the former mercury mine/smelter located on the site of the recycling facility. Each factor was tested in a univariate regression with total mercury in urine, blood, hair, and nails. Median biomarker concentrations were 4.04 ??g/g-Cr (urine), 2.58 ??g/L (blood), 3.95 ??g/g (hair), and 1.16 ??g/g (nails). Occupational category was significantly correlated (p < 0.001) with both blood and urinary mercury concentrations but not with hair or nail mercury. Four individuals had urinary mercury concentrations in a range previously found to be associated with subtle neurological and subjective symptoms (e.g., fatigue, loss of appetite, irritability), and one worker had a urinary mercury concentration in a range associated with a high probability of neurological effects and proteinuria. Comparison of results by occupational category found that workers directly involved with the recycling operation had the highest blood and urinary mercury levels. Those who worked at the facility but were not directly involved with the recycling operation had higher levels than those who did not work at the facility. Copyright ?? 2008 JOEH, LLC.

  13. ELISA for sulfonamides and its application for screening in water contamination.

    PubMed

    Shelver, Weilin L; Shappell, Nancy W; Franek, Milan; Rubio, Fernando R

    2008-08-13

    Two enzyme-linked immunosorbent assays (ELISAs) were tested for their suitability for detecting sulfonamides in wastewater from various stages in wastewater treatment plants (WWTPs), the river into which the wastewater is discharged, and two swine-rearing facilities. The sulfamethoxazole ELISA cross-reacts with several compounds, achieving detection limits of <0.04 microg/L for sulfamethoxazole (SMX), sulfamethoxypyridine, sulfachloropyridine, and sulfamethoxine, whereas the sulfamethazine (SMZ) ELISA is more compound specific, with a detection limit of <0.03 microg/L. Samples from various stages of wastewater purifications gave 0.6-3.1 microg/L by SMX-ELISA, whereas river samples were approximately 10-fold lower, ranging from below detection to 0.09 microg/L. Swine wastewater samples analyzed by the SMX-ELISA were either at or near detectable limits from one facility, whereas the other facility had concentrations of approximately 0.5 microg/L, although LC-MS/MS did not confirm the presence of SMX. Sulfamethazine ELISA detected no SMZ in either WWTP or river samples. In contrast, wastewater samples from swine facilities analyzed by SMZ-ELISA were found to contain approximately 30 microg/L [piglet (50-100 lb) wastewater] and approximately 7 microg/L (market-weight hog wastewater). Sulfamethazine ELISA analyses of wastewater from another swine facility found concentrations to be near or below detection limits. A solid phase extraction method was used to isolate and concentrate sulfonamides from water samples prior to LC-MS/MS multiresidue confirmatory analysis. The recoveries at 1 microg/L fortification ranged from 42 +/- 4% for SMZ to 88 +/- 4% for SMX ( n = 6). The ELISA results in the WWTPs were confirmed by LC-MS/MS, as sulfonamide multiresidue confirmatory analysis identified SMX, sulfapyridine, and sulfasalazine to be present in the wastewater. Sulfamethazine presence at one swine-rearing facility was also confirmed by LC-MS/MS, demonstrating the usefulness of the ELISA technique as a rapid and high-throughput screening method.

  14. Design and construction of coal/biomass to liquids (CBTL) process development unit (PDU) at the University of Kentucky Center for Applied Energy Research (CAER)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Placido, Andrew; Liu, Kunlei; Challman, Don

    This report describes a first phase of a project to design, construct and commission an integrated coal/biomass-to-liquids facility at a capacity of 1 bbl. /day at the University of Kentucky Center for Applied Energy Research (UK-CAER) – specifically for construction of the building and upstream process units for feed handling, gasification, and gas cleaning, conditioning and compression. The deliverables from the operation of this pilot plant [when fully equipped with the downstream process units] will be firstly the liquid FT products and finished fuels which are of interest to UK-CAER’s academic, government and industrial research partners. The facility will producemore » research quantities of FT liquids and finished fuels for subsequent Fuel Quality Testing, Performance and Acceptability. Moreover, the facility is expected to be employed for a range of research and investigations related to: Feed Preparation, Characteristics and Quality; Coal and Biomass Gasification; Gas Clean-up/ Conditioning; Gas Conversion by FT Synthesis; Product Work-up and Refining; Systems Analysis and Integration; and Scale-up and Demonstration. Environmental Considerations - particularly how to manage and reduce carbon dioxide emissions from CBTL facilities and from use of the fuels - will be a primary research objectives. Such a facility has required significant lead time for environmental review, architectural/building construction, and EPC services. UK, with DOE support, has advanced the facility in several important ways. These include: a formal EA/FONSI, and permits and approvals; construction of a building; selection of a range of technologies and vendors; and completion of the upstream process units. The results of this project are the FEED and detailed engineering studies, the alternate configurations and the as-built plant - its equipment and capabilities for future research and demonstration and its adaptability for re-purposing to meet other needs. These are described in some detail in this report, along with lessons learned.« less

  15. Proposal for an Accelerator R&D User Facility at Fermilab's Advanced Superconducting Test Accelerator (ASTA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Church, M.; Edwards, H.; Harms, E.

    2013-10-01

    Fermilab is the nation’s particle physics laboratory, supported by the DOE Office of High Energy Physics (OHEP). Fermilab is a world leader in accelerators, with a demonstrated track-record— spanning four decades—of excellence in accelerator science and technology. We describe the significant opportunity to complete, in a highly leveraged manner, a unique accelerator research facility that supports the broad strategic goals in accelerator science and technology within the OHEP. While the US accelerator-based HEP program is oriented toward the Intensity Frontier, which requires modern superconducting linear accelerators and advanced highintensity storage rings, there are no accelerator test facilities that support themore » accelerator science of the Intensity Frontier. Further, nearly all proposed future accelerators for Discovery Science will rely on superconducting radiofrequency (SRF) acceleration, yet there are no dedicated test facilities to study SRF capabilities for beam acceleration and manipulation in prototypic conditions. Finally, there are a wide range of experiments and research programs beyond particle physics that require the unique beam parameters that will only be available at Fermilab’s Advanced Superconducting Test Accelerator (ASTA). To address these needs we submit this proposal for an Accelerator R&D User Facility at ASTA. The ASTA program is based on the capability provided by an SRF linac (which provides electron beams from 50 MeV to nearly 1 GeV) and a small storage ring (with the ability to store either electrons or protons) to enable a broad range of beam-based experiments to study fundamental limitations to beam intensity and to develop transformative approaches to particle-beam generation, acceleration and manipulation which cannot be done elsewhere. It will also establish a unique resource for R&D towards Energy Frontier facilities and a test-bed for SRF accelerators and high brightness beam applications in support of the OHEP mission of Accelerator Stewardship.« less

  16. Polybrominated dibenzo-p-dioxins/dibenzofurans and polybrominated diphenyl ethers in soil, vegetation, workshop-floor dust, and electronic shredder residue from an electronic waste recycling facility and in soils from a chemical industrial complex in eastern China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jing Ma; Rudolf Addink; Sehun Yun

    2009-10-01

    In this study, 11 2,3,7,8-substituted PBDD/Fs and 10 polybrominated diphenyl ether (PBDE) congeners were determined in electronic shredder waste, workshop-floor dust, soil, and leaves (of plants on the grounds of the facility) from a large-scale electronic wastes (e-waste) recycling facility and in surface soil from a chemical-industrial complex (comprising a coke-oven plant, a coal-fired power plant, and a chlor-alkali plant) as well as agricultural areas in eastern China. Total PBDD/F concentrations in environmental samples were in the range of 113-818 pg/g dry wt (dw) for leaves, 392-18,500 pg/g dw for electronic shredder residues, 716-80,0000 pg/g dw for soil samples, andmore » 89,600-14,3000 pg/g dw for workshop-floor dust from the e-waste recycling facility and in a range from nondetect (ND) to 427 pg/g dw in soil from the chemical-industrial complex. The highest mean concentrations of total PBDD/Fs were found in soil samples and workshop-floor dust from the e-waste recycling facility. The dioxin-like toxic equivalent (measured as TEQ) concentrations of PBDD/Fs were greater than the TEQs of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) reported in our previous study for the same set of samples. The concentrations of PBDFs were several orders of magnitude higher than the concentrations of PBDDs in samples from the e-waste facility or from soil from the chemical-industrial complex. A significant correlation was found between the concentrations of {Sigma}PBDD/Fs and {Sigma}PBDEs (r = 0.769, p < 0.01) and between SPBDD/Fs and the previously reported SPCDD/F concentrations (r = 0.805, p < 0.01). The estimated daily human intakes of TEQs contributed by PBDD/Fs via soil/dust ingestion and dermal exposures in e-waste recycling facilities were higher than the intakes of TEQs contributed by PCDD/Fs, calculated in our previous study. 45 refs., 2 figs., 2 tabs.« less

  17. The Precision Expandable Radar Calibration Sphere (PERCS) With Applications for Laser Imaging and Ranging

    DTIC Science & Technology

    2008-09-01

    HF facilities such as HAARP in Alaska, EISCAT in Norway, and Arecibo in Puerto Rico; (3) the chain of high latitude SuperDARN radars used for auroral...DF arrays, ground HF transmitters such as the Navy relocatable over the horizon radar (ROTHR) and the Air Force/Navy HAARP system would be employed...United States and Australia; (2) high power HF facilities such as HAARP in Alaska, EISCAT in Norway, and Arecibo in Puerto Rico; (3) the chain of high

  18. On the geodetic stability of the Goddard Optical Research Facility

    NASA Technical Reports Server (NTRS)

    Webster, W. J., Jr.; Lowman, P. D., Jr.; Allenby, R. J.

    1981-01-01

    Seismic observations of earthquakes and blasts, geologic analysis of Landsat images, and a search of the historical record was examined. However, no evidence for tectonic motion was found. Some faulting is present in the area but no evidence of seismic activity was found. No elastic resonances in the range from 0.3 to 15 Hz were found. It is concluded that, except for ground water induced changes, the facility is stable at least to the 0.5 cm level.

  19. Experimental program for real gas flow code validation at NASA Ames Research Center

    NASA Technical Reports Server (NTRS)

    Deiwert, George S.; Strawa, Anthony W.; Sharma, Surendra P.; Park, Chul

    1989-01-01

    The experimental program for validating real gas hypersonic flow codes at NASA Ames Rsearch Center is described. Ground-based test facilities used include ballistic ranges, shock tubes and shock tunnels, arc jet facilities and heated-air hypersonic wind tunnels. Also included are large-scale computer systems for kinetic theory simulations and benchmark code solutions. Flight tests consist of the Aeroassist Flight Experiment, the Space Shuttle, Project Fire 2, and planetary probes such as Galileo, Pioneer Venus, and PAET.

  20. Design Guidance for Command, Control, Communications, and Intelligence (C3I) Facility Cooling Systems

    DTIC Science & Technology

    1989-05-01

    Typical ranges are from 50 to 70 OF. If a chiller is dedicated to serving water-cooled electronic equipment, the chilled water temperature setpoint can...can be satisfied with 50 OF chilled water. The COP of the dedicated chiller is improved by raising the chilled water setpoint , and the total life-cycle...USACERL TECHNICAL REPORT E-89/10 May 1989 Studies in Optimizing HVAC Hardware for C31 Facilities US Army Corps of Engineers Construction Engineering

  1. The 0.040-scale space shuttle orbiter base heating model tests in the Lewis Research Center space power facility

    NASA Technical Reports Server (NTRS)

    Dezelick, R. A.

    1976-01-01

    Space shuttle base heating tests were conducted using a 0.040-scale model in the Plum Brook Space Power Facility of The NASA Lewis Research Center. The tests measured heat transfer rates, pressure distributions, and gas recovery temperatures on the orbiter vehicle 2A base configuration resulting from engine plume impingement. One hundred and sixty-eight hydrogen-oxygen engine firings were made at simulated flight altitudes ranging from 120,000 to 360,000 feet.

  2. Next-generation laser retroreflectors for GNSS, solar system exploration, geodesy, gravitational physics and earth observation

    NASA Astrophysics Data System (ADS)

    Dell'Agnello, S.; Boni, A.; Cantone, C.; Ciocci, E.; Martini, M.; Patrizi, G.; Tibuzzi, M.; Delle Monache, G.; Vittori, R.; Bianco, G.; Currie, D.; Intaglietta, N.; Salvatori, L.; Lops, C.; Contessa, S.; Porcelli, L.; Mondaini, C.; Tuscano, P.; Maiello, M.

    2017-11-01

    The SCF_Lab (Satellite/lunar/gnss laser ranging and altimetry Characterization Facility Laboratory) of INFNLNF is designed to cover virtually LRAs (Laser Retroreflector Arrays) of CCRs (Cube Corner Retroreflectors) for missions in the whole solar system, with a modular organization of its instrumentation, two redundant SCF (SCF_Lab Characterization Facilities), and an evolutionary measurement approach, including customization and potentially upgrade on-demand. See http://www.lnf.infn.it/esperimenti/etrusco/ for a general description.

  3. Vice President Mike Pence Visits Kennedy Space Center - Tour of

    NASA Image and Video Library

    2018-02-21

    Vice President Mike Pence views Boeing’s Starliner spacecraft for the Crew Flight Test during a tour of the company’s Commercial Crew and Cargo Processing Facility at NASA's Kennedy Space Center in Florida, on Feb. 21, 2018. During his visit, Pence chaired a meeting of the National Space Council in the high bay of the center's Space Station Processing Facility. The council's role is to advise the president regarding national space policy and strategy, and review the nation's long-range goals for space activities.

  4. Vice President Mike Pence Visits Kennedy Space Center - Tour of

    NASA Image and Video Library

    2018-02-21

    Vice President Mike Pence, center, and members of the National Space Council hear from a Boeing employee during a tour of the Boeing Commercial Crew and Cargo Processing Facility at NASA's Kennedy Space Center in Florida, on Feb. 21, 2018. During his visit, Pence chaired a meeting of the council in the high bay of the center's Space Station Processing Facility. The council's role is to advise the president regarding national space policy and strategy, and review the nation's long-range goals for space activities.

  5. Vice President Mike Pence Visits Kennedy Space Center - Tour of

    NASA Image and Video Library

    2018-02-21

    Vice President Mike Pence, center, speaks to Boeing executives and members of the National Space Council during a tour of the Boeing Commercial Crew and Cargo Processing Facility at NASA's Kennedy Space Center in Florida, on Feb. 21, 2018. During his visit, Pence chaired a meeting of the council in the high bay of the center's Space Station Processing Facility. The council's role is to advise the president regarding national space policy and strategy, and review the nation's long-range goals for space activities.

  6. EHS and FME Lend Their Expertise to NCI Campus Refurbishment Project | Poster

    Cancer.gov

    In October 2015, the NCI executive officer and the director of NCI’s Office of Space and Facilities Management (OSFM) announced a wide-ranging refurbishment plan for NCI at Frederick. Since then, a project team comprising members from the Office of Scientific Operations, the Management Operations Support Branch, OSFM, the Center for Cancer Research, the Environment, Health, and Safety (EHS) directorate, and the Facilities Maintenance and Engineering (FME) directorate have met regularly with the laboratory groups affected by the refurbishment plan. Read more...

  7. Langley Aerothermodynamic Facilities Complex: Enhancements and Testing Capabilities

    NASA Technical Reports Server (NTRS)

    Micol, J. R.

    1998-01-01

    Description, capabilities, recent upgrades, and utilization of the NASA Langley Research Center (LaRC) Aerothermodynamic Facilities Complex (AFC) are presented. The AFC consists of five hypersonic, blow-down-to-vacuum wind tunnels that collectively provide a range of Mach number from 6 to 20, unit Reynolds number from 0.04 to 22 million per foot and, most importantly for blunt configurations, normal shock density ratio from 4 to 12. These wide ranges of hypersonic simulation parameters are due, in part, to the use of three different test gases (air, helium, and tetrafluoromethane), thereby making several of the facilities unique. The Complex represents nearly three-fourths of the conventional (as opposed to impulse)-type hypersonic wind tunnels operational in this country. AFC facilities are used to assess and optimize the hypersonic aerodynamic performance and aeroheating characteristics of aerospace vehicle concepts and to provide benchmark aerodynamic/aeroheating data fr generating the flight aerodynamic databook and final design of the thermal protection system (TPS) (e.g., establishment of flight limitations not to exceed TPS design limits). Modifications and enhancements of AFC hardware components and instrumentation have been pursued to increase capability, reliability, and productivity in support of programmatic goals. Examples illustrating facility utilization in recent years to generate essentially all of the experimental hypersonic aerodynamic and aeroheating information for high-priority, fast-paced Agency programs are presented. These programs include Phase I of the Reusable Launch Vehicle (RLV) Advanced Technology Demonstrator, X-33 program, PHase II of the X-33 program, X-34 program, the Hyper-X program ( a Mach 5,7, and 10 airbreathing propulsion flight experiment), and the X-38 program (Experimental Crew Return Vehicle, X-CRV). Current upgrades/enchancements and future plans for the AFC are discussed.

  8. The influence of facility agriculture production on phthalate esters distribution in black soils of northeast China.

    PubMed

    Zhang, Ying; Wang, Pengjie; Wang, Lei; Sun, Guoqiang; Zhao, Jiaying; Zhang, Hui; Du, Na

    2015-02-15

    The current study investigates the existence of 15 phthalate esters (PAEs) in surface soils (27 samples) collected from 9 different facility agriculture sites in the black soil region of northeast China, during the process of agricultural production (comprising only three seasons spring, summer and autumn). Concentrations of the 15 PAEs detected significantly varied from spring to autumn and their values ranged from 1.37 to 4.90 mg/kg-dw, with a median value of 2.83 mg/kg-dw. The highest concentration of the 15 PAEs (4.90 mg/kg-dw) was determined in summer when mulching film was used in the greenhouses. Probably an increase in environmental temperature was a major reason for PAE transfer from the mulching film into the soil and coupled with the increased usage of chemical fertilizers in greenhouses. Results showed that of the 15 PAEs, di(2-ethylhexyl) phthalate(DEHP), di-n-butyl phthalate (DBP), diethyl phthalate (DEP) and dimethyl phthalate (DMP) were in abundance with the mean value of 1.12 ± 0.22, 0.46 ± 0.05, 0.36 ± 0.04, and 0.17 ± 0.01 mg/kg-dw, respectively; and their average contributions in spring, summer, and autumn ranged between 64.08 and 90.51% among the 15 PAEs. The results of Principal Component Analysis (PCA) indicated the concentration of these four main PAEs significantly differed among the facility agricultures investigated, during the process of agricultural production. In comparison with foreign and domestic results of previous researches, it is proved that the black soils of facility agriculture in northeast China show higher pollution situation comparing with non-facility agriculture soils. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. An integrated analytical framework for quantifying the LCOE of waste-to-energy facilities for a range of greenhouse gas emissions policy and technical factors.

    PubMed

    Townsend, Aaron K; Webber, Michael E

    2012-07-01

    This study presents a novel integrated method for considering the economics of waste-to-energy (WTE) facilities with priced greenhouse gas (GHG) emissions based upon technical and economic characteristics of the WTE facility, MSW stream, landfill alternative, and GHG emissions policy. The study demonstrates use of the formulation for six different policy scenarios and explores sensitivity of the results to ranges of certain technical parameters as found in existing literature. The study shows that details of the GHG emissions regulations have large impact on the levelized cost of energy (LCOE) of WTE and that GHG regulations can either increase or decrease the LCOE of WTE depending on policy choices regarding biogenic fractions from combusted waste and emissions from landfills. Important policy considerations are the fraction of the carbon emissions that are priced (i.e. all emissions versus only non-biogenic emissions), whether emissions credits are allowed due to reducing fugitive landfill gas emissions, whether biogenic carbon sequestration in landfills is credited against landfill emissions, and the effectiveness of the landfill gas recovery system where waste would otherwise have been buried. The default landfill gas recovery system effectiveness assumed by much of the industry yields GHG offsets that are very close to the direct non-biogenic GHG emissions from a WTE facility, meaning that small changes in the recovery effectiveness cause relatively larger changes in the emissions factor of the WTE facility. Finally, the economics of WTE are dependent on the MSW stream composition, with paper and wood being advantageous, metal and glass being disadvantageous, and plastics, food, and yard waste being either advantageous or disadvantageous depending upon the avoided tipping fee and the GHG emissions price. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Travel Burden to Breast MRI and Utilization: Are Risk and Sociodemographics Related?

    PubMed

    Onega, Tracy; Lee, Christoph I; Benkeser, David; Alford-Teaster, Jennifer; Haas, Jennifer S; Tosteson, Anna N A; Hill, Deirdre; Shi, Xun; Henderson, Louise M; Hubbard, Rebecca A

    2016-06-01

    Mammography, unlike MRI, is relatively geographically accessible. Additional travel time is often required to access breast MRI. However, the amount of additional travel time and whether it varies on the basis of sociodemographic or breast cancer risk factors is unknown. The investigators examined screening mammography and MRI between 2005 and 2012 in the Breast Cancer Surveillance Consortium by (1) travel time to the closest and actual mammography facility used and the difference between the two, (2) women's breast cancer risk factors, and (3) sociodemographic characteristics. Logistic regression was used to examine the odds of traveling farther than the closest facility in relation to women's characteristics. Among 821,683 screening mammographic examinations, 76.6% occurred at the closest facility, compared with 51.9% of screening MRI studies (n = 3,687). The median differential travel time among women not using the closest facility for mammography was 14 min (interquartile range, 8-25 min) versus 20 min (interquartile range, 11-40 min) for breast MRI. Differential travel time for both imaging modalities did not vary notably by breast cancer risk factors but was significantly longer for nonurban residents. For non-Hispanic black compared with non-Hispanic white women, the adjusted odds of traveling farther than the closest facility were 9% lower for mammography (odds ratio, 0.91; 95% confidence interval, 0.87-0.95) but more than two times higher for MRI (odds ratio, 2.64; 95% confidence interval, 1.36-5.13). Breast cancer risk factors were not related to excess travel time for screening MRI, but sociodemographic factors were, suggesting the possibility that geographic distribution of advanced imaging may exacerbated disparities for some vulnerable populations. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  11. Modular Filter and Source-Management Upgrade of RADAC

    NASA Technical Reports Server (NTRS)

    Lanzi, R. James; Smith, Donna C.

    2007-01-01

    In an upgrade of the Range Data Acquisition Computer (RADAC) software, a modular software object library was developed to implement required functionality for filtering of flight-vehicle-tracking data and management of tracking-data sources. (The RADAC software is used to process flight-vehicle metric data for realtime display in the Wallops Flight Facility Range Control Center and Mobile Control Center.)

  12. Response of Rocky Mountain elk (Cervus elaphus) to wind-power development

    USGS Publications Warehouse

    Walter, W. David; Leslie, David M.; Jenks, J.A.

    2006-01-01

    Wind-power development is occurring throughout North America, but its effects on mammals are largely unexplored. Our objective was to determine response (i.e., home-range, diet quality) of Rocky Mountain elk (Cervus elaphus) to wind-power development in southwestern Oklahoma. Ten elk were radiocollared in an area of wind-power development on 31 March 2003 and were relocated bi-weekly through March 2005. Wind-power construction was initiated on 1 June 2003 and was completed by December 2003 with 45 active turbines. The largest composite home range sizes (>80 km2) occurred April-June and September, regardless of the status of wind-power facility development. The smallest home range sizes (<50 km2) typically occurred in October-February when elk aggregated to forage on winter wheat. No elk left the study site during the study and elk freely crossed the gravel roads used to access the wind-power facility. Carbon and nitrogen isotopes and percent nitrogen in feces suggested that wind-power development did not affect nutrition of elk during construction. Although disturbance and loss of some grassland habitat was apparent, elk were not adversely affected by wind-power development as determined by home range and dietary quality.

  13. Polybrominated dibenzo-p-dioxins/ dibenzofurans and polybrominated diphenyl ethers in soil, vegetation, workshop-floor dust, and electronic shredder residue from an electronic waste recycling facility and in soils from a chemical industrial complex in eastern China.

    PubMed

    Ma, Jing; Addink, Rudolf; Yun, Sehun; Cheng, Jinping; Wang, Wenhua; Kannan, Kurunthachalam

    2009-10-01

    The formation and release of polybrominated dibenzo-p-dioxins and dibenzofurans (PBDD/Fs) from the incineration of electronic wastes (e-waste) that contain brominated flame retardants (BFRs) are a concern. However, studies on the determination of PBDD/Fs in environmental samples collected from e-waste recycling facilities are scarce. In this study, 11 2,3,7,8-substituted PBDD/Fs and 10 polybrominated diphenyl ether (PBDE) congeners were determined in electronic shredder waste, workshop-floor dust soil, and leaves (of plants on the grounds of the facility) from a large-scale e-waste recycling facility and in surface soil from a chemical-industrial complex (comprising a coke-oven plant, a coal-fired power plant, and a chlor-alkali plant) as well as agricultural areas in eastern China. Total PBDD/F concentrations in environmental samples were in the range of 113-818 pg/g dry wt (dw) for leaves, 392-18500 pg/g dw for electronic shredder residues, 716-800000 pg/g dw for soil samples, and 89600-pg/g dw for workshop-floor dust from the e-waste recycling facility and in a range from nondetect (ND) to 427 pg/g dw in soil from the chemical-industrial complex. The highest mean concentrations of total PBDD/Fs were found in soil samples and workshop-floor dust from the e-waste recycling facility. The dioxin-like toxic equivalent (measured as TEQ) concentrations of PBDD/Fs were greater than the TEQs of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) reported in our previous study for the same set of samples. The concentrations of PBDFs were several orders of magnitude higher than the concentrations of PBDDs in samples from the e-waste facility or from soil from the chemical-industrial complex. A significant correlation was found between the concentrations of sigmaPBDD/Fs and sigmaPBDEs (r = 0.769, p < 0.01) and between sigmaPBDD/Fs and the previously reported sigmaPCDD/F concentrations (r = 0.805, p < 0.01). The estimated daily human intakes of TEQs contributed by PBDD/Fs via soil/dust ingestion and dermal exposures in e-waste recycling facilities were higher than the intakes of TEQs contributed by PCDD/ Fs, calculated in our previous study.

  14. Geochemical data package for the Hanford immobilized low-activity tank waste performance assessment (ILAW PA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DI Kaplan; RJ Serne

    Lockheed Martin Hanford Company (LMHC) is designing and assessing the performance of disposal facilities to receive radioactive wastes that are stored in single- and double-shell tanks at the Hanford Site. The preferred method of disposing of the portion that is classified as low-activity waste is to vitrify the liquid/slurry and place the solid product in near-surface, shallow-land burial facilities. The LMHC project to assess the performance of these disposal facilities is the Hanford Immobilized Low-Activity Tank Waste (ILAW) Performance Assessment (PA) activity. The goal of this project is to provide a reasonable expectation that the disposal of the waste ismore » protective of the general public, groundwater resources, air resources, surface-water resources, and inadvertent intruders. Achieving this goal will require prediction of contaminant migration from the facilities. This migration is expected to occur primarily via the movement of water through the facilities, and the consequent transport of dissolved contaminants in the porewater of the vadose zone. Pacific Northwest National Laboratory assists LMHC in their performance assessment activities. One of the PNNL tasks is to provide estimates of the geochemical properties of the materials comprising the disposal facility, the disturbed region around the facility, and the physically undisturbed sediments below the facility (including the vadose zone sediments and the aquifer sediments in the upper unconfined aquifer). The geochemical properties are expressed as parameters that quantify the adsorption of contaminants and the solubility constraints that might apply for those contaminants that may exceed solubility constraints. The common parameters used to quantify adsorption and solubility are the distribution coefficient (K{sub d}) and the thermodynamic solubility product (K{sub sp}), respectively. In this data package, the authors approximate the solubility of contaminants using a more simplified construct, called the solution concentration limit, a constant value. In future geochemical data packages, they will determine whether a more rigorous measure of solubility is necessary or warranted based on the dose predictions emanating from the ILAW 2001 PA and reviewers' comments. The K{sub d}s and solution concentration limits for each contaminant are direct inputs to subsurface flow and transport codes used to predict the performance of the ILAW system. In addition to the best-estimate K{sub d}s, a reasonable conservative value and a range are provided. They assume that K{sub d} values are log normally distributed over the cited ranges. Currently, they do not give estimates for the range in solubility limits or their uncertainty. However, they supply different values for both the K{sub d}s and solution concentration limits for different spatial zones in the ILAW system and supply time-varying K{sub d}s for the concrete zone, should the final repository design include concrete vaults or cement amendments to buffer the system pH.« less

  15. ARC-2006-ACD06-0177-013

    NASA Image and Video Library

    2006-10-04

    CEV (Crew Escape Vehicle) capsule Balistic Range testing to examine static and dynamic stability characteristics (at the Hypervelocity Free-Flight Facility) HFF - Don Holt (L) & Don Bowling (r) in control room examining poloroids

  16. ARC-2006-ACD06-0177-002

    NASA Image and Video Library

    2006-09-20

    CEV (Crew Escape Vehicle) capsule Balistic Range testing to examine static and dynamic stability characteristics (at the Hypervelocity Free-Flight Facility) HFF - model M-1 in 40 degree initial launch angle with sabot

  17. ARC-2006-ACD06-0177-003

    NASA Image and Video Library

    2006-09-20

    CEV (Crew Escape Vehicle) capsule Balistic Range testing to examine static and dynamic stability characteristics (at the Hypervelocity Free-Flight Facility) HFF - model M-1 in 40 degree initial launch angle with sabot

  18. {open_quotes}Airborne Research Australia (ARA){close_quotes} a new research aircraft facility on the southern hemisphere

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hacker, J.M.

    1996-11-01

    {open_quotes}Airborne Research Australia{close_quotes} (ARA) is a new research aircraft facility in Australia. It will serve the scientific community of Australia and will also make its aircraft and expertise available for commercial users. To cover the widest possible range of applications, the facility will operate up to five research aircraft, from a small, low-cost platform to medium-sized multi-purpose aircraft, as well as a unique high altitude aircraft capable of carrying scientific loads to altitudes of up to 15km. The aircraft will be equipped with basic instrumentation and data systems, as well as facilities to mount user-supplied instrumentation and systems internally andmore » externally on the aircraft. The ARA operations base consisting of a hangar, workshops, offices, laboratories, etc. is currently being constructed at Parafield Airport near Adelaide/South Australia. The following text reports about the current state of development of the facility. An update will be given in a presentation at the Conference. 6 figs.« less

  19. Status and Perspectives of Neutron Imaging Facilities

    NASA Astrophysics Data System (ADS)

    Lehmann, E.; Trtik, P.; Ridikas, D.

    The methodology and the application range of neutron imaging techniques have been significantly improved at numerous facilities worldwide in the last decades. This progress has been achieved by new detector systems, the setup of dedicated, optimized and flexible beam lines and the much better understanding of the complete imaging process thanks to complementary simulations. Furthermore, new applications and research topics were found and implemented. However, since the quality and the number of neutron imaging facilities depend much on the access to suitable beam ports, there is still an enormous potential to implement state-of-the-art neutron imaging techniques at many more facilities. On the one hand, there are prominent and powerful sources which do not intend/accept the implementation of neutron imaging techniques due to the priorities set for neutron scattering and irradiation techniques exclusively. On the other hand, there are modern and useful devices which remain under-utilized and have either not the capacity or not the know-how to develop attractive user programs and/or industrial partnerships. In this overview of the international status of neutron imaging facilities, we will specify details about the current situation.

  20. Fabrication and characterization of SPR chips with the modified bovine serum albumin

    NASA Astrophysics Data System (ADS)

    Chen, Xing; Zhang, Lu-lu; Cui, Da-fu

    2016-03-01

    A facile surface plasmon resonance (SPR) chip is developed for small molecule determination and analysis. The SPR chip was prepared based on a self assembling principle, in which the modified bovine serum albumin (BSA) was directly self-assembled onto the bare gold surface. The surface morphology of the chip with the modified BSA was investigated by atomic force microscopy (AFM) and its optical properties were characterized. The surface binding capacity of the bare facile SPR chip with a uniform morphology is 8 times of that of the bare control SPR chip. Based on the experiments of immune reaction between cortisol antibody and cortisol derivative, the sensitivity of the facile SPR chip with the modified BSA is much higher than that of the control SPR chip with the un-modified BSA. The facile SPR chip has been successfully used to detect small molecules. The lowest detection limit is 5 ng/mL with a linear range of 5—100 ng/mL for cortisol analysis. The novel facile SPR chip can also be applied to detect other small molecules.

Top