Sample records for federal technology alert

  1. Driver alertness and fatigue : summary of completed research projects, 1995-98

    DOT National Transportation Integrated Search

    2000-01-01

    This document describes projects in the Federal Motor Carrier Safety Administration's (FMCSA) Driver Alertness and Fatigue Research and Technology (R&T) focus area that were completed during the years 1995 to 1998 under the former Office of Motor Car...

  2. Green Roofs: Federal Energy Management Program (FEMP) Federal Technology Alert

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scholz-Barth, K.; Tanner, S.

    In a ''green roof,'' a layer of vegetation (e.g., a roof garden) covers the surface of a roof to provide shade, cooler indoor and outdoor temperatures, and effective storm-water management to reduce runoff. The main components are waterproofing, soil, and plants. There are two basic kinds: intensive and extensive. An intensive green roof often features large shrubs and trees, and it can be expensive to install and maintain. An extensive green roof features shallow soil and low-growing, horizontally spreading plants that can thrive in the alpine conditions of many rooftops. These plants do not require a lot of water ormore » soil, and they can tolerate a significant amount of exposure to the sun and wind. This Federal Technology Alert focuses on the benefits, design, and implementation of extensive green roofs and includes criteria for their use on federal facilities.« less

  3. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  4. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  5. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  6. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  7. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  8. The Seismic Alert System of Mexico (SASMEX): Performance and Evolution

    NASA Astrophysics Data System (ADS)

    Espinosa Aranda, J.

    2013-05-01

    Originally the Seismic Alert System of Mexico (SASMEX) was proposed to integrate the Seismic Alert System of Mexico City (SAS), operating since 1991, with the Seismic Alert System of Oaxaca City (SASO), in services since 2003. And today, after the intense big earthquake activity observed in our world during 2010 and 2011, local governments of Mexico City, Oaxaca Estate, and the Mexican Ministry of the Interior have been promoting the expansion of this technological EEW development. Until 2012 SASMEX better coverage includes 48 new field seismic sensors (FS) deployed over the seismic region of Jalisco, Colima, Michoacan and Puebla, with someone enhancements over Guerrero and Oaxaca, to reach 97 FS. During 2013, 35 new FS has been proposed to SASMEX enhancements covering the Chiapas and Veracruz seismic regions. The SASMEX, with the support of the Mexico Valley Broadcasters Association (ARVM) since 1993, automatically issue Public and Preventive earthquake early warning signals in the Cities of Mexico, Toluca, Acapulco, Chilpancingo, and Oaxaca. The seismic warning range in each case is seated in accordance with local Civil Protection Authorities: Public Alert, if they expect strong earthquake effects, and Preventive Alert one, the effect could be moderated. Now the SASMEX warning time opportunity could be different to the 60 sec. average typically generated when SAS warned earthquake effects coming from Guerrero to Mexico City valley. Mexican EEW issued today reach: 16 Public and 62 Preventive Alert in Mexico City; 25 Public and 19 Preventive Alerts in Oaxaca City; also 14 Public and 4 Preventive Alerts in Acapulco; 14 Public and 5 Preventive Alerts in Chilpancingo. The earthquakes events registered by SASMEX FS until now reach 3448. With the support of private and Federal telecommunications infrastructure like, TELMEX, Federal Electric Commission, and the Mexican Security Ministry, it was developed a redundant communication system with pads to link the different Cities, trough VHF and UHF radio signals, Fiber Optics, and Satellite technologies, to reach more reliability and availability SASMEX functions and services. To increase the seismic early warning efficiency the Mexico City Historical Center Authorities, promoted the installation of the NOAA VHF radio transmitters system to cover the Mexico City valley, operating with the Specific Area Message Encoding (SAME) called NWR-SAME, and with the Emergency Alert Systems (EAS) protocol of United States. As an enhancement of the NOAA receiver protocol, it was innovated to permit fast Public Alert issue, in no more than 2 sec. The new receiver applied in Mexico is called SARMEX™. Local and federal authorities acquired 90,000 SARMEX™ receivers to be distributed manly in public schools of Mexican cities covered by the SASMEX™ signals; the measure with the aim to promote better natural hazard prevention attitude in the Mexican young population segment.

  9. Expert Systems Technology and Its Implication for Archives. National Archives Technical Information Paper No. 9.

    ERIC Educational Resources Information Center

    Michelson, Avra

    This report introduces archivists to the potential of expert systems for improving archives administration and alerts them to ways in which they can expect intelligent technologies to impact federal record-keeping systems and scholarly research methods. The report introduces the topic by describing expert systems used in three Fortune 500…

  10. 77 FR 26701 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-07

    ... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: In this document, the Federal Communications Commission (Commission) amends its rules governing the Emergency Alert... the manner in which EAS Participants must be able to receive alert messages formatted in the Common...

  11. 77 FR 28387 - Federal Advisory Committee Act; Communications Security, Reliability, and Interoperability Council

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-14

    ... practice recommendations on emergency alerting systems such as promoting E9-1-1 reliability and alerting platforms--Emergency Alert System and Common Alerting Protocol. DATES: June 6, 2012. ADDRESSES: Federal... Advisory Committee that will provide recommendations to the FCC regarding best practices and actions the...

  12. 47 CFR 10.210 - WEA participation election procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Section 10.210 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS... requirements implemented by the Commission; and (2) Commits to support the development and deployment of technology for the “C” interface, the CMS provider Gateway, the CMS provider infrastructure, and mobile...

  13. 47 CFR 10.210 - CMAS participation election procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Section 10.210 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM... requirements implemented by the Commission; and (2) Commits to support the development and deployment of technology for the “C” interface, the CMS provider Gateway, the CMS provider infrastructure, and mobile...

  14. 47 CFR 10.210 - CMAS participation election procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Section 10.210 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM... requirements implemented by the Commission; and (2) Commits to support the development and deployment of technology for the “C” interface, the CMS provider Gateway, the CMS provider infrastructure, and mobile...

  15. 47 CFR 10.210 - WEA participation election procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Section 10.210 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS... requirements implemented by the Commission; and (2) Commits to support the development and deployment of technology for the “C” interface, the CMS provider Gateway, the CMS provider infrastructure, and mobile...

  16. 78 FR 16806 - The Commercial Mobile Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-19

    ... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 10 [PS Docket No. 07-287; DA 13-280] The Commercial Mobile Alert System AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: In this document, the Commission amends its rules to change the name of the Commercial Mobile Alert System (CMAS...

  17. 76 FR 32367 - Agency Information Collection Activities, Proposed Collection; Comment Request; Integrated Public...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-06

    ...; Integrated Public Alert and Warning Systems (IPAWS) Inventory AGENCY: Federal Emergency Management Agency... proposed revision of the information collection concerning public alert and warning systems at the Federal... evaluation and assessment of existing public alert and warning resources and their integration with the...

  18. 76 FR 54245 - Agency Information Collection Activities: Submission for OMB Review; Comment Request, Integrated...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-31

    ... Request, Integrated Public Alert and Warning Systems (IPAWS) Inventory AGENCY: Federal Emergency... system to alert and warn the American people in situations of war, terrorist attack, natural disaster, or... inventory of public alert and warning resources, capabilities, and the degree of integration at the Federal...

  19. Traffic Alert and Collision Avoidance System (TCAS): Cockpit Display of Traffic Information (CDTI) investigation. Phase 1: Feasibility study

    NASA Technical Reports Server (NTRS)

    Burgess, Malcolm; Davis, Dean; Hollister, Walter; Sorensen, John A.

    1991-01-01

    The possibility of the Threat Alert and Collision Avoidance System (TCAS) traffic sensor and display being used for meaningful Cockpit Display of Traffic Information (CDTI) applications has resulted in the Federal Aviation Administration initiating a project to establish the technical and operational requirements to realize this potential. Phase 1 of the project is presented here. Phase 1 was organized to define specific CDTI applications for the terminal area, to determine what has already been learned about CDTI technology relevant to these applications, and to define the engineering required to supply the remaining TCAS-CDTI technology for capacity benefit realization. The CDTI applications examined have been limited to those appropriate to the final approach and departure phases of flight.

  20. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.300 Alert aggregator. [Reserved] ...

  1. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.300 Alert aggregator. [Reserved] ...

  2. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...

  3. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...

  4. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...

  5. 76 FR 80780 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-27

    ... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: In this document, the Commission amends its rules governing the Emergency Alert System (EAS) rules to extend the deadline for EAS Participants to be able to receive Common Alerting Protocol (CAP)- formatted EAS alerts to...

  6. Lessons from Hawaii: A Blessing in Disguise.

    PubMed

    Deitchman, Scott; Dallas, Cham E; Burkle, Frederick

    2018-03-20

    On January 13, 2018, Hawaii experienced an erroneous alert that falsely warned of an imminent ballistic missile strike. Rather than focus on the inconvenience caused by the false alert, we used reporting of the event to identify the missing elements that would characterize a system that could save lives by alerting and informing the public in a nuclear detonation. These include warnings that contain essential information rather than directing recipients to secondary sources; a system that issues alerts directly from federal agencies that will have the earliest warning; a robust multimodal alerting system that can deliver messages before and after the detonation; and swift activation of federal agencies immediately upon warning.

  7. 47 CFR 10.240 - Notification to new subscribers of non-participation in CMAS.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-participation in CMAS. 10.240 Section 10.240 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.240... EMERGENCY ALERTS (Commercial Mobile Alert Service) [[CMS provider

  8. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...

  9. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...

  10. 47 CFR 10.410 - Prioritization.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Prioritization. 10.410 Section 10.410 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message... required to transmit Imminent Threat Alerts and AMBER Alerts on a first in-first out (FIFO) basis. ...

  11. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  12. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  13. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  14. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...

  15. 77 FR 41331 - Commercial Mobile Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ... Mobile Alert System AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of... with the Commission's Commercial Mobile Alert System (CMS), Second Report and Order (``CMAS Second... Alert System rules contained in the Commission's Second Report and Order, FCC 08- 164, published at 73...

  16. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  17. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  18. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  19. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  20. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  1. 77 FR 33661 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-07

    ... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of... Commission's Review of the Emergency Alert System, Fifth Report and Order (Order). This document is... Expiration Date: November 30, 2012. Title: Part 11--Emergency Alert System, Fifth Report and Order, FCC 12-7...

  2. 47 CFR 10.220 - Withdrawal of election to participate in CMAS.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 10.220 Section 10.220 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.220 Withdrawal of election... subscribers as well as the Federal Communications Commission at least sixty (60) days prior to the withdrawal...

  3. 47 CFR 10.410 - Prioritization.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Prioritization. 10.410 Section 10.410 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.410 Prioritization. A Participating CMS Provider is required to transmit Presidential Alerts...

  4. A new approach to monitoring and alerting congestion in airspace sectors

    DOT National Transportation Integrated Search

    2014-09-28

    The Federal Aviation Administration (FAA) Traffic Flow Management System (TFMS)currently declares an alert for any 15 minute interval in which the predicted demand exceeds the Monitor/Alert Parameter (MAP)for any airport, sector, or fix. For airports...

  5. 47 CFR 80.1117 - Procedure for receipt and acknowledgement of distress alerts.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... radiotelephony of receipt of a distress alert from a ship station or a ship earth station must be given in the... telegraphy of receipt of a distress alert from a ship earth station must be given by the coast earth station... distress alerts. 80.1117 Section 80.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED...

  6. 47 CFR 80.1117 - Procedure for receipt and acknowledgement of distress alerts.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... radiotelephony of receipt of a distress alert from a ship station or a ship earth station must be given in the... telegraphy of receipt of a distress alert from a ship earth station must be given by the coast earth station... distress alerts. 80.1117 Section 80.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED...

  7. 47 CFR 80.1117 - Procedure for receipt and acknowledgement of distress alerts.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... radiotelephony of receipt of a distress alert from a ship station or a ship earth station must be given in the... telegraphy of receipt of a distress alert from a ship earth station must be given by the coast earth station... distress alerts. 80.1117 Section 80.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED...

  8. 47 CFR 10.440 - Embedded reference prohibition.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.440 Embedded reference prohibition. A CMAS Alert Message processed by a...

  9. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM... that each Participating Commercial Mobile Service provider is required to support and perform at its...

  10. 47 CFR 10.420 - Message elements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Message elements. 10.420 Section 10.420 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.420 Message elements. A CMAS Alert Message processed by a Participating CMS Provider shall...

  11. 47 CFR 10.10 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Definitions. 10.10 Section 10.10 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM General Information § 10.10 Definitions. (a) Alert Message. An Alert Message is a message that is intended to provide the...

  12. 47 CFR 10.440 - Embedded reference prohibition.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.440 Embedded reference prohibition. A CMAS Alert Message processed by a...

  13. 47 CFR 10.440 - Embedded reference prohibition.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.440 Embedded reference prohibition. A CMAS Alert Message processed by a...

  14. 47 CFR 10.430 - Character limit.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Character limit. 10.430 Section 10.430 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.430 Character limit. A CMAS Alert Message processed by a Participating CMS Provider must not...

  15. 75 FR 12770 - Agency Information Collection Activities: Submission for OMB Review; Comment Request, OMB No...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-17

    ...; Radiological Emergency Preparedness Program Alert and Notification Phone Survey AGENCY: Federal Emergency...; OMB No. 1660-NEW; FEMA Form 111, Radiological Emergency Preparedness Program Alert and Notification...: Radiological Emergency Preparedness Program Alert and Notification Phone Survey. Type of information collection...

  16. 47 CFR 80.1117 - Procedure for receipt and acknowledgement of distress alerts.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Communications Commission, 445 12th Street, SW., Washington, DC (Reference Information Center) or at the National... given by the coast earth station receiving the distress alert by retransmitting the ship station... distress alerts. 80.1117 Section 80.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED...

  17. 47 CFR 80.1117 - Procedure for receipt and acknowledgement of distress alerts.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Communications Commission, 445 12th Street, SW., Washington, DC (Reference Information Center) or at the National... given by the coast earth station receiving the distress alert by retransmitting the ship station... distress alerts. 80.1117 Section 80.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED...

  18. Work zone intrusion alert technologies : assessment and practical guidance : final report.

    DOT National Transportation Integrated Search

    2017-06-01

    A work zone intrusion alert technology is a type of safety system that is used in a roadway work zone to alert field workers and secure time for them to escape when errant vehicles intrude into the work zone. Although such technologies have potential...

  19. 76 FR 72306 - Federal Housing Administration (FHA) Appraiser Roster: Appraiser Qualifications for Placement on...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-23

    ... Appraiser Roster regulations by replacing the obsolete references to the Credit Alert Interactive Voice Response System (CAIVRS) with references to its successor, the online-based Credit Alert Verification... propose the elimination references to the Credit Alert Interactive Voice Response System (CAIVRS). On July...

  20. 76 FR 41441 - Federal Housing Administration (FHA) Appraiser Roster: Appraiser Qualifications for Placement on...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-14

    ... the FHA Appraiser Roster by replacing the obsolete references to the Credit Alert Interactive Voice Response System with references to its successor, the online-based Credit Alert Verification Reporting...'s Limited Denial of Participation list, or in HUD's Credit Alert Interactive Voice Response System...

  1. 47 CFR 76.1711 - Emergency alert system (EAS) tests and activation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Emergency alert system (EAS) tests and activation. 76.1711 Section 76.1711 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Documents to be Maintained for Inspection § 76.1711 Emergency alert system (EAS)...

  2. 47 CFR 76.1711 - Emergency alert system (EAS) tests and activation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Emergency alert system (EAS) tests and activation. 76.1711 Section 76.1711 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Documents to be Maintained for Inspection § 76.1711 Emergency alert system (EAS)...

  3. Bar Code Medication Administration Technology: Characterization of High-Alert Medication Triggers and Clinician Workarounds.

    PubMed

    Miller, Daniel F; Fortier, Christopher R; Garrison, Kelli L

    2011-02-01

    Bar code medication administration (BCMA) technology is gaining acceptance for its ability to prevent medication administration errors. However, studies suggest that improper use of BCMA technology can yield unsatisfactory error prevention and introduction of new potential medication errors. To evaluate the incidence of high-alert medication BCMA triggers and alert types and discuss the type of nursing and pharmacy workarounds occurring with the use of BCMA technology and the electronic medication administration record (eMAR). Medication scanning and override reports from January 1, 2008, through November 30, 2008, for all adult medical/surgical units were retrospectively evaluated for high-alert medication system triggers, alert types, and override reason documentation. An observational study of nursing workarounds on an adult medicine step-down unit was performed and an analysis of potential pharmacy workarounds affecting BCMA and the eMAR was also conducted. Seventeen percent of scanned medications triggered an error alert of which 55% were for high-alert medications. Insulin aspart, NPH insulin, hydromorphone, potassium chloride, and morphine were the top 5 high-alert medications that generated alert messages. Clinician override reasons for alerts were documented in only 23% of administrations. Observational studies assessing for nursing workarounds revealed a median of 3 clinician workarounds per administration. Specific nursing workarounds included a failure to scan medications/patient armband and scanning the bar code once the dosage has been removed from the unit-dose packaging. Analysis of pharmacy order entry process workarounds revealed the potential for missed doses, duplicate doses, and doses being scheduled at the wrong time. BCMA has the potential to prevent high-alert medication errors by alerting clinicians through alert messages. Nursing and pharmacy workarounds can limit the recognition of optimal safety outcomes and therefore workflow processes must be continually analyzed and restructured to yield the intended full benefits of BCMA technology. © 2011 SAGE Publications.

  4. 47 CFR 80.1121 - Receipt and acknowledgement of distress alerts by ship stations and ship earth stations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... by ship stations and ship earth stations. 80.1121 Section 80.1121 Telecommunication FEDERAL... § 80.1121 Receipt and acknowledgement of distress alerts by ship stations and ship earth stations. (a) Ship or ship earth stations that receive a distress alert must, as soon as possible, inform the master...

  5. 47 CFR 80.1119 - Receipt and acknowledgement of distress alerts by coast stations and coast earth stations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... by coast stations and coast earth stations. 80.1119 Section 80.1119 Telecommunication FEDERAL... § 80.1119 Receipt and acknowledgement of distress alerts by coast stations and coast earth stations. (a... for coast stations.) (b) Coast earth stations in receipt of distress alerts must ensure that they are...

  6. 47 CFR 80.1119 - Receipt and acknowledgement of distress alerts by coast stations and coast earth stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... by coast stations and coast earth stations. 80.1119 Section 80.1119 Telecommunication FEDERAL... § 80.1119 Receipt and acknowledgement of distress alerts by coast stations and coast earth stations. (a... for coast stations.) (b) Coast earth stations in receipt of distress alerts must ensure that they are...

  7. 47 CFR 80.1121 - Receipt and acknowledgement of distress alerts by ship stations and ship earth stations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... by ship stations and ship earth stations. 80.1121 Section 80.1121 Telecommunication FEDERAL... § 80.1121 Receipt and acknowledgement of distress alerts by ship stations and ship earth stations. (a) Ship or ship earth stations that receive a distress alert must, as soon as possible, inform the master...

  8. 47 CFR 80.1119 - Receipt and acknowledgement of distress alerts by coast stations and coast earth stations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... by coast stations and coast earth stations. 80.1119 Section 80.1119 Telecommunication FEDERAL... § 80.1119 Receipt and acknowledgement of distress alerts by coast stations and coast earth stations. (a... for coast stations.) (b) Coast earth stations in receipt of distress alerts must ensure that they are...

  9. 47 CFR 80.1121 - Receipt and acknowledgement of distress alerts by ship stations and ship earth stations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... by ship stations and ship earth stations. 80.1121 Section 80.1121 Telecommunication FEDERAL... § 80.1121 Receipt and acknowledgement of distress alerts by ship stations and ship earth stations. (a) Ship or ship earth stations that receive a distress alert must, as soon as possible, inform the master...

  10. 47 CFR 80.1121 - Receipt and acknowledgement of distress alerts by ship stations and ship earth stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... by ship stations and ship earth stations. 80.1121 Section 80.1121 Telecommunication FEDERAL... § 80.1121 Receipt and acknowledgement of distress alerts by ship stations and ship earth stations. (a) Ship or ship earth stations that receive a distress alert must, as soon as possible, inform the master...

  11. 47 CFR 80.1119 - Receipt and acknowledgement of distress alerts by coast stations and coast earth stations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... by coast stations and coast earth stations. 80.1119 Section 80.1119 Telecommunication FEDERAL... § 80.1119 Receipt and acknowledgement of distress alerts by coast stations and coast earth stations. (a... for coast stations.) (b) Coast earth stations in receipt of distress alerts must ensure that they are...

  12. 47 CFR 80.1119 - Receipt and acknowledgement of distress alerts by coast stations and coast earth stations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... by coast stations and coast earth stations. 80.1119 Section 80.1119 Telecommunication FEDERAL... § 80.1119 Receipt and acknowledgement of distress alerts by coast stations and coast earth stations. (a... for coast stations.) (b) Coast earth stations in receipt of distress alerts must ensure that they are...

  13. 47 CFR 80.1121 - Receipt and acknowledgement of distress alerts by ship stations and ship earth stations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... by ship stations and ship earth stations. 80.1121 Section 80.1121 Telecommunication FEDERAL... § 80.1121 Receipt and acknowledgement of distress alerts by ship stations and ship earth stations. (a) Ship or ship earth stations that receive a distress alert must, as soon as possible, inform the master...

  14. 47 CFR 10.460 - Retransmission frequency. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Retransmission frequency. [Reserved] 10.460 Section 10.460 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.460 Retransmission frequency. [Reserved] ...

  15. Summary of findings from the PIREP-based analyses conducted during the 1988 to 1990 evaluations of TDWR-based and TDWR/LLWAS-based alert services provided to landing/departing pilots

    DOT National Transportation Integrated Search

    1992-07-01

    The Federal Aviation Administration (FAA) is developing the Terminal Doppler Weather Radar (TDWR). Starting in 1985, the TDWR Program conducted a series of evaluations of a TDWR-based alert service to provide wind shear and microburst alerts to landi...

  16. Chemical Safety Alert: Safer Technology and Alternatives

    EPA Pesticide Factsheets

    This alert is intended to introduce safer technology concepts and general approaches, explains the concepts and principles, and gives brief examples of the integration of safer technologies into facility risk management activities.

  17. Visual Alert System

    NASA Technical Reports Server (NTRS)

    1985-01-01

    A visual alert system resulted from circuitry developed by Applied Cybernetics Systems for Langley as part of a space related telemetry system. James Campman, Applied Cybernetics president, left the company and founded Grace Industries, Inc. to manufacture security devices based on the Langley technology. His visual alert system combines visual and audible alerts for hearing impaired people. The company also manufactures an arson detection device called the electronic nose, and is currently researching additional applications of the NASA technology.

  18. 47 CFR 10.450 - Geographic targeting.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Geographic targeting. 10.450 Section 10.450 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.450 Geographic targeting. This section establishes minimum requirements for the geographic...

  19. 47 CFR 10.10 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM General Information § 10... Participating Commercial Mobile Service Provider under this part. (b) Common Alerting Protocol. The Common...), or any subsequent version of CAP adopted by OASIS and implemented by the CMAS. (c) Commercial Mobile...

  20. 47 CFR 10.400 - Classification.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Classification. 10.400 Section 10.400 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.400 Classification. A Participating CMS Provider is required to receive and transmit three...

  1. 47 CFR 10.400 - Classification.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Classification. 10.400 Section 10.400 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.400 Classification. A Participating CMS Provider is required to receive and transmit three...

  2. 47 CFR 10.400 - Classification.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Classification. 10.400 Section 10.400 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS Alert Message Requirements § 10.400 Classification. A Participating CMS Provider is required to receive and transmit three classes...

  3. 47 CFR 10.400 - Classification.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Classification. 10.400 Section 10.400 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.400 Classification. A Participating CMS Provider is required to receive and transmit three...

  4. 47 CFR 10.400 - Classification.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Classification. 10.400 Section 10.400 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS Alert Message Requirements § 10.400 Classification. A Participating CMS Provider is required to receive and transmit three classes...

  5. 76 FR 72922 - Federal Advisory Committee Act; Communications Security, Reliability, and Interoperability Council

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-28

    ... alerting systems, 9-1-1 location accuracy, and network security. The FCC will attempt to accommodate as... FEDERAL COMMUNICATIONS COMMISSION Federal Advisory Committee Act; Communications Security... persons that the Federal Communications Commission's (FCC) third Communications Security, Reliability, and...

  6. 47 CFR 10.470 - Roaming.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Roaming. 10.470 Section 10.470 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Alert Message Requirements § 10.470 Roaming. When, pursuant to a roaming agreement (see § 20.12 of this chapter), a...

  7. 47 CFR 10.210 - CMAS participation election procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false CMAS participation election procedures. 10.210 Section 10.210 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.210 CMAS participation election procedures...

  8. 47 CFR 10.440 - Embedded reference prohibition.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS Alert... address) to a resource on the Internet, or an embedded telephone number. This prohibition does not apply...

  9. 47 CFR 10.440 - Embedded reference prohibition.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Embedded reference prohibition. 10.440 Section 10.440 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS Alert... address) to a resource on the Internet, or an embedded telephone number. This prohibition does not apply...

  10. PERCLOS : a valid psychophysiological measure of alertness as assessed by psychomotor vigilance

    DOT National Transportation Integrated Search

    1998-10-01

    This Tech Brief summarizes an Intelligent Transportation System (ITS) study titled "Evaluation of Techniques for Ocular Measurement as an Index of Fatigue and as the Basis for Alertness Management." The study was funded in part by the Federal Highway...

  11. KSC-00padig050

    NASA Image and Video Library

    2000-10-18

    This close-up shows the pager-sized Personal Cabin Pressure Altitude Monitor developed by Jan Zysko, chief of the KSC Spaceport Engineering and Technology directorate's data and electronic systems branch. The monitor alerts wearers of a potentially dangerous or deteriorating cabin pressure altitude condition, which can lead to life-threatening hypoxia. Zysko originally designed the monitor to offer Space Shuttle and Space Station crew members added independent notification about any depressurization. However, it has drawn the interest of such organizations as the Federal Aviation Administration for use in commercial airliners and private aircraft as well

  12. 47 CFR 10.270 - Subscribers' right to terminate subscription.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Subscribers' right to terminate subscription. 10.270 Section 10.270 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.270 Subscribers' right to...

  13. 47 CFR 10.260 - Timing of subscriber notification.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Timing of subscriber notification. 10.260 Section 10.260 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.260 Timing of subscriber notification. A CMS...

  14. 47 CFR 80.1114 - False distress alerts.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false False distress alerts. 80.1114 Section 80.1114 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating Procedures for Distress and...

  15. 47 CFR 80.1114 - False distress alerts.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false False distress alerts. 80.1114 Section 80.1114 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating Procedures for Distress and...

  16. 47 CFR 80.335 - Procedures for canceling false distress alerts.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... priority message by way of the same land earth station through which the false distress alert was sent.... 80.335 Section 80.335 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress...

  17. 47 CFR 80.335 - Procedures for canceling false distress alerts.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... priority message by way of the same land earth station through which the false distress alert was sent.... 80.335 Section 80.335 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress...

  18. 47 CFR 80.335 - Procedures for canceling false distress alerts.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... priority message by way of the same land earth station through which the false distress alert was sent.... 80.335 Section 80.335 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress...

  19. 47 CFR 80.335 - Procedures for canceling false distress alerts.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... priority message by way of the same land earth station through which the false distress alert was sent.... 80.335 Section 80.335 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress...

  20. 47 CFR 80.335 - Procedures for canceling false distress alerts.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... priority message by way of the same land earth station through which the false distress alert was sent.... 80.335 Section 80.335 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Safety Watch Requirements and Procedures Distress...

  1. 47 CFR 11.52 - EAS code and Attention Signal Monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... technologies, such as instant messaging and email) the distribution of Common Alert Protocol (CAP)-formatted... Integrated Public Alert and Warning System (IPAWS) to enable (whether through “pull” interface technologies...

  2. 47 CFR 11.52 - EAS code and Attention Signal Monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... technologies, such as instant messaging and email) the distribution of Common Alert Protocol (CAP)-formatted... Integrated Public Alert and Warning System (IPAWS) to enable (whether through “pull” interface technologies...

  3. 47 CFR 11.52 - EAS code and Attention Signal Monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... technologies, such as instant messaging and email) the distribution of Common Alert Protocol (CAP)-formatted... Integrated Public Alert and Warning System (IPAWS) to enable (whether through “pull” interface technologies...

  4. Alerts in mobile healthcare applications: requirements and pilot study.

    PubMed

    Kafeza, Eleanna; Chiu, Dickson K W; Cheung, S C; Kafeza, Marina

    2004-06-01

    Recent advances in mobile technologies have greatly extended traditional communication technologies to mobile devices. At the same time, healthcare environments are by nature "mobile" where doctors and nurses do not have fixed workspaces. Irregular and exceptional events are generated in daily hospital routines, such as operations rescheduling, laboratory/examination results, and adverse drug events. These events may create requests that should be delivered to the appropriate person at the appropriate time. Those requests that are classified as urgent are referred to as alerts. Efficient routing and monitoring of alerts are keys to quality and cost-effective healthcare services. Presently, these are generally handled in an ad hoc manner. In this paper, we propose the use of a healthcare alert management system to handle these alert messages systematically. We develop a model for specifying alerts that are associated with medical tasks and a set of parameters for their routing. We design an alert monitor that matches medical staff and their mobile devices to receive alerts, based on the requirements of these alerts. We also propose a mechanism to handle and reroute, if necessary, an alert message when it has not been acknowledged within a specific deadline.

  5. Jetliner Alert Systems

    NASA Technical Reports Server (NTRS)

    1983-01-01

    NASA research and design has significantly improved crew alert systems. The Engine Indication and Crew Alerting System (EICAS), developed by Psycho-Linguistic Research Associates, is technologically advanced and able to order alerts by priority. Ames has also developed computer controlled voice synthesizers for readouts during difficult landing approaches. This is available to airplane manufacturers.

  6. 47 CFR 10.230 - New CMS providers participation in CMAS.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false New CMS providers participation in CMAS. 10.230 Section 10.230 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.230 New CMS providers participation in CMAS...

  7. 47 CFR 10.250 - Notification to existing subscribers of non-participation in CMAS.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Notification to existing subscribers of non-participation in CMAS. 10.250 Section 10.250 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.250...

  8. 47 CFR 10.280 - Subscribers' right to opt out of CMAS notifications.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Subscribers' right to opt out of CMAS notifications. 10.280 Section 10.280 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Election to Participate in Commercial Mobile Alert System § 10.280 Subscribers' right...

  9. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  10. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  11. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  12. 44 CFR 208.36 - Reimbursement for Alert.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Reimbursement for Alert. 208.36 Section 208.36 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT... § 208.41 of this part. (4) Food and beverages for Task Force Members and Support Specialists when DHS...

  13. Human factors considerations for the integration of traffic information and alerts on an airport surface map

    DOT National Transportation Integrated Search

    2010-12-01

    The purpose of this document is to provide human factors considerations in the integration of traffic information and indications and alerts for runway status on an airport surface moving map. The US DOT Volpe Center, in support of the Federal Aviati...

  14. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  15. 14 CFR 135.150 - Public address and crewmember interphone systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... to alert flight crewmembers; (iii) For the alerting system required by paragraph (b)(7)(ii) of this... systems. 135.150 Section 135.150 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Aircraft and Equipment § 135.150 Public address and crewmember interphone systems. No person may operate an...

  16. 47 CFR 80.1113 - Transmission of a distress alert.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Procedures for Distress and Safety Communications § 80.1113 Transmission of a distress alert. (a) The... Selective-Calling Equipment in the Maritime Mobile Service,” with Annexes 1 through 5, 2004, as specified in... Annexes 1 through 5, 2004, are incorporated by reference. The Director of the Federal Register approves...

  17. 47 CFR 80.1113 - Transmission of a distress alert.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Procedures for Distress and Safety Communications § 80.1113 Transmission of a distress alert. (a) The... Selective-Calling Equipment in the Maritime Mobile Service,” with Annexes 1 through 5, 2004, as specified in... Annexes 1 through 5, 2004, are incorporated by reference. The Director of the Federal Register approves...

  18. 78 FR 15722 - Federal Advisory Committee Act; Communications Security, Reliability, and Interoperability Council

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-12

    ... Alerting, E9-1-1 Location Accuracy, Network Security Best Practices, DNSSEC Implementation Practices for... FEDERAL COMMUNICATIONS COMMISSION Federal Advisory Committee Act; Communications Security... Security, Reliability, and Interoperability Council (CSRIC) meeting that was scheduled for March 6, 2013 is...

  19. Climate Prediction Center - Outlooks: UV Alert Forecast

    Science.gov Websites

    Organization Search Go Search the CPC Go About Us Our Mission Who We Are Contact Us CPC Information CPC Web Team USA.gov is the U.S. Government's official Web portal to all Federal, state and local government Web resources and services. HOME > Stratosphere Home > Stratosphere UV Index > UV Alert

  20. 77 FR 31483 - Airworthiness Directives; Gulfstream Aerospace Corporation Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-29

    ... Management Facility between 9 a.m. and 5 p.m., Monday through Friday, except Federal holidays. The AD docket... Service Information We reviewed Gulfstream III Alert Customer Bulletin 21, including Service Reply Card, dated May 18, 2012 (for Model G-1159A airplanes); and Gulfstream II/IIB Alert Customer Bulletin 36...

  1. 47 CFR 80.1115 - Transmission of a distress alert by a station not itself in distress.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Transmission of a distress alert by a station not itself in distress. 80.1115 Section 80.1115 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and...

  2. 47 CFR 80.1115 - Transmission of a distress alert by a station not itself in distress.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Transmission of a distress alert by a station not itself in distress. 80.1115 Section 80.1115 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and...

  3. 47 CFR 10.350 - CMAS testing requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... maintenance windows. (3) A Participating CMS Provider may forego an RMT if the RMT is pre-empted by actual... Gateway Administrator using a defined test message. Real event codes or alert messages shall not be used... automated log of RMT messages received by the CMS Provider Gateway from the Federal Alert Gateway. (b...

  4. 47 CFR 10.350 - CMAS Testing requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... maintenance windows. (3) A Participating CMS Provider may forego an RMT if the RMT is pre-empted by actual... Gateway Administrator using a defined test message. Real event codes or alert messages shall not be used... automated log of RMT messages received by the CMS Provider Gateway from the Federal Alert Gateway. (b...

  5. An investigation of air transportation technology at the Massachusetts Institute of Technology, 1990-1991

    NASA Technical Reports Server (NTRS)

    Simpson, Robert W.

    1991-01-01

    Brief summaries are given of research activities at the Massachusetts Institute of Technology (MIT) under the sponsorship of the FAA/NASA Joint University Program. Topics covered include hazard assessment and cockpit presentation issues for microburst alerting systems; the situational awareness effect of automated air traffic control (ATC) datalink clearance amendments; a graphical simulation system for adaptive, automated approach spacing; an expert system for temporal planning with application to runway configuration management; deterministic multi-zone ice accretion modeling; alert generation and cockpit presentation for an integrated microburst alerting system; and passive infrared ice detection for helicopter applications.

  6. Fatigue and alertness in the United States railroad industry part II: fatigue research in the Office of Research and Development at the Federal Railroad Administration

    DOT National Transportation Integrated Search

    2000-03-31

    A new approach for improving safety in the U.S. railroad industry was initiated in the 1990's by the Federal Railroad Administration (FRA). The FRA has stressed cooperative partnerships with other federal agencies, railroad management, labor unions, ...

  7. Diversion Alert: 1-Year Evaluation Across Northern New England, 2013–2014

    PubMed Central

    Desrosiers, Clare

    2016-01-01

    This report describes Diversion Alert, a unique online tool aimed at reducing misuse and diversion of prescription drugs, and reports the results of a 1-year evaluation of Diversion Alert’s impact in Maine. We used a quasi-experimental research design to compare survey data in Maine with those of neighboring states (New Hampshire and Vermont, 2013 and 2014). Compared with their counterparts in New Hampshire and Vermont who did not use Diversion Alert, prescribers and pharmacists in Maine who used Diversion Alert increased their communication with patients and other providers involved in their patients’ care, became aware of patients arrested for prescription drugs possession or diversion, used best practices associated with prevention or detection of addiction and diversion more frequently, and attributed positive changes in their prescribing practices to Diversion Alert. In combination with other state and federal programs, Diversion Alert may be an effective tool to help prevent the misuse of opioid medications. PMID:27880633

  8. Sensory Overload and Technology in Critical Care.

    PubMed

    Wung, Shu-Fen; Malone, Daniel C; Szalacha, Laura

    2018-06-01

    In this focus group study, we identified issues associated with sensory overload from medical technology alarms/alerts for intensive care unit nurses. Participants indicated that alarms from cardiopulmonary monitors, ventilators, and intravenous pumps contributed the most to sensory overload and, yet, these alarms were also deemed the most helpful. Alerts/alarms from electronic health records and medication dispensing systems were rated low in contributing to sensory overload, as well as being the least helpful. Specific device/technology barriers, related to device alerts/alarms, are detailed. Future user-centered and integrated improvements in alarm systems associated with medical devices in the intensive care unit are needed. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Impact of e-alert systems on the care of patients with acute kidney injury.

    PubMed

    Breighner, Crystal M; Kashani, Kianoush B

    2017-09-01

    With the recent advancement in electronic health record systems and meaningful use of information technology incentive programs (i.e., the American Recovery and Reinvestment Act, the Health Information Technology for Economic and Clinical Health Act, and the Centers for Medicare & Medicaid Services), interest in clinical decision support systems has risen. These systems have been used to examine a variety of different syndromes with variable reported effects. In recent years, electronic alerts (e-alerts) have been implemented at various institutions to decrease the morbidity associated with acute kidney injury (AKI). AKI is common, accounting for 1 in 7 hospital admissions, and is associated with increased length of hospital stay and mortality. AKI is often underrecognized, causing delayed intervention. The use of e-alerts may result in earlier recognition and intervention, as well as decreased morbidity and mortality. This must be balanced with the possibility of increased resource utilization that e-alerts may cause. Before widespread implementation, the ethical and legal consequences of not following e-alert recommendations must be established, and the optimal algorithm for AKI e-alert detection must be determined. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Integrative Approach for a Transformative Freshman-Level STEM Curriculum

    PubMed Central

    Curran, Kathleen L.; Olsen, Paul E.; Nwogbaga, Agashi P.; Stotts, Stephanie

    2016-01-01

    In 2014 Wesley College adopted a unified undergraduate program of evidence-based high-impact teaching practices. Through foundation and federal and state grant support, the college completely revised its academic core curriculum and strengthened its academic support structures by including a comprehensive early alert system for at-risk students. In this core, science, technology, engineering, and mathematics (STEM) faculty developed fresh manifestations of integrated concept-based introductory courses and revised upper-division STEM courses around student-centered learning. STEM majors can participate in specifically designed paid undergraduate research experiences in directed research elective courses. Such a college-wide multi-tiered approach results in institutional cultural change. PMID:27064213

  11. KSC00padig049

    NASA Image and Video Library

    2000-10-01

    Jan Zysko (left) and Rich Mizell (right) test a Personal Cabin Pressure Altitude Monitor in an altitude chamber at Tyndall Air Force Base in Florida. Zysko invented the pager-sized monitor that alerts wearers of a potentially dangerous or deteriorating cabin pressure altitude condition, which can lead to life-threatening hypoxia. Zysko is chief of the KSC Spaceport Engineering and Technology directorate's data and electronic systems branch. Mizell is a Shuttle processing engineer. The monitor, which has drawn the interest of such organizations as the Federal Aviation Administration for use in commercial airliners and private aircraft, was originally designed to offer Space Shuttle and Space Station crew members added independent notification about any depressurization

  12. KSC-00padig049

    NASA Image and Video Library

    2000-10-01

    Jan Zysko (left) and Rich Mizell (right) test a Personal Cabin Pressure Altitude Monitor in an altitude chamber at Tyndall Air Force Base in Florida. Zysko invented the pager-sized monitor that alerts wearers of a potentially dangerous or deteriorating cabin pressure altitude condition, which can lead to life-threatening hypoxia. Zysko is chief of the KSC Spaceport Engineering and Technology directorate's data and electronic systems branch. Mizell is a Shuttle processing engineer. The monitor, which has drawn the interest of such organizations as the Federal Aviation Administration for use in commercial airliners and private aircraft, was originally designed to offer Space Shuttle and Space Station crew members added independent notification about any depressurization

  13. Cabin Pressure Monitors Notify Pilots to Save Lives

    NASA Technical Reports Server (NTRS)

    2015-01-01

    In 2013, San Diego-based Aviation Technology Inc. obtained an exclusive license for the technology behind the cabin pressure monitor invented at Kennedy Space Center and built its own version of the product. The Alt Alert is designed to save lives by alerting aircraft pilots and crews when cabin pressure becomes dangerously low.

  14. Unmanned Aircraft Systems (UAS) Integration in the National Airspace System (NAS) Project: Advanced Collision Avoidance System for UAS (ACAS Xu) Interoperability White Paper Presentation

    NASA Technical Reports Server (NTRS)

    Fern, Lisa

    2017-01-01

    The Phase 1 DAA Minimum Operational Performance Standards (MOPS) provided requirements for two classes of DAA equipment: equipment Class 1 contains the basic DAA equipment required to assist a pilot in remaining well clear, while equipment Class 2 integrates the Traffic Alert and Collision Avoidance (TCAS) II system. Thus, the Class 1 system provides RWC functionality only, while the Class 2 system is intended to provide both RWC and Collision Avoidance (CA) functionality, in compliance with the Minimum Aviation System Performance (MASPS) for the Interoperability of Airborne Collision Avoidance Systems. The FAAs TCAS Program Office is currently developing Airborne Collision Avoidance System X (ACAS X) to support the objectives of the Federal Aviation Administrations (FAA) Next Generation Air Transportation System Program (NextGen). ACAS X has a suite of variants with a common underlying design that are intended to be optimized for their intended airframes and operations. ACAS Xu being is designed for UAS and allows for new surveillance technologies and tailored logic for platforms with different performance characteristics. In addition to Collision Avoidance (CA) alerting and guidance, ACAS Xu is being tuned to provide RWC alerting and guidance in compliance with the SC 228 DAA MOPS. With a single logic performing both RWC and CA functions, ACAS Xu will provide industry with an integrated DAA solution that addresses many of the interoperability shortcomings of Phase I systems. While the MOPS for ACAS Xu will specify an integrated DAA system, it will need to show compliance with the RWC alerting thresholds and alerting requirements defined in the DAA Phase 2 MOPS. Further, some functional components of the ACAS Xu system such as the remote pilots displayed guidance might be mostly references to the corresponding requirements in the DAA MOPS. To provide a seamless, integrated, RWC-CA system to assist the pilot in remaining well clear and avoiding collisions, several issues need to be addressed within the Phase 2 SC-228 DAA efforts. Interoperability of the RWC and CA alerting and guidance, and ensuring pilot comprehension, compliance and performance, will be a primary research area.

  15. Education and Training Module in Alertness Management

    NASA Technical Reports Server (NTRS)

    Mallis, M. M.; Brandt, S. L.; Oyung, R. L.; Reduta, D. D.; Rosekind, M. R.

    2006-01-01

    The education and training module (ETM) in alertness management has now been integrated as part of the training regimen of the Pilot Proficiency Awards Program ("WINGS") of the Federal Aviation Administration. Originated and now maintained current by the Fatigue Countermeasures Group at NASA Ames Research Center, the ETM in Alertness Management is designed to give pilots the benefit of the best and most recent research on the basics of sleep physiology, the causes of fatigue, and strategies for managing alertness during flight operations. The WINGS program is an incentive program that encourages pilots at all licensing levels to participate in recurrent training, upon completion of which distinctive lapel or tie pins (wings) and certificates of completion are awarded. In addition to flight training, all WINGS applicants must attend at least one FAA-sponsored safety seminar, FAA-sanctioned safety seminar, or industry recurrent training program. The Fatigue Countermeasures Group provides an FAA-approved industry recurrent training program through an on-line General Aviation (GA) WINGS ETM in alertness management to satisfy this requirement. Since 1993, the Fatigue Countermeasures Group has translated fatigue and alertness information to operational environments by conducting two-day ETM workshops oriented primarily toward air-carrier operations subject to Part 121 of the Federal Aviation Regulations pertaining to such operations. On the basis of the information presented in the two-day ETM workshops, an ETM was created for GA pilots and was transferred to a Web-based version. To comply with the requirements of the WINGS Program, the original Web-based version has been modified to include hypertext markup language (HTML) content that makes information easily accessible, in-depth testing of alertness-management knowledge, new interactive features, and increased informational resources for GA pilots. Upon successful completion of this training module, a participant receives a computer- screen display of a certificate of completion. The certificate, which includes the pilot s name and an identifying number, can be printed out and submitted, for ground training credit, with the pilot s WINGS application.

  16. 75 FR 28249 - Comment Sought on Measures Designed To Assist U.S. Wireless Consumers To Avoid “Bill Shock”

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-20

    ... feasibility of instituting usage alerts and cut-off mechanisms similar to those required under the European... other things, the Commission noted that advances in technology, including usage alerts delivered via... the kind and degree of information available to consumers.'' On the issue of usage alerts, the...

  17. Commercial Mobile Alert Service (CMAS) Scenarios

    DTIC Science & Technology

    2012-05-01

    Commercial Mobile Alert Service (CMAS) Scenarios The WEA Project Team May 2012 SPECIAL REPORT CMU/SEI-2012-SR-020 CERT® Division, Software ...Homeland Security under Contract No. FA8721-05-C-0003 with Carnegie Mellon University for the operation of the Software Engineering Institute, a federally...DISTRIBUTES IT “AS IS.” References herein to any specific commercial product, process, or service by trade name, trade mark, manufacturer, or otherwise

  18. Alertness management : strategic naps in operational settings

    DOT National Transportation Integrated Search

    1995-01-01

    Managing fatigue in complex operational settings requires attention to multiple factors, including hours of service, scheduling, education and training, countermeasures, technology, and research. Alertness-management strategies can be used to promote...

  19. Weather Advisory: Tornados | Poster

    Cancer.gov

    Summer months carry the threat of severe storms and tornados in our area. Take a few moments to consider how well you are prepared in the event of a tornado warning. The time to prepare for a tornado is before it happens. The Federal Emergency Management Agency (FEMA) provides information on how to prepare and what to do in the event of a tornado. Take a few moments to read the important safety information FEMA has assembled: http://www.ready.gov/tornadoes. Sign Up for Text Alerts from Frederick County You can also sign up for text alerts to your cell phone from Frederick County at http://www.frederickcountymd.gov/ALERT.

  20. Cognitive Radio will revolutionize American transportation

    ScienceCinema

    None

    2018-02-07

    Cognitive Radio will revolutionize American transportation. Through smart technology, it will anticipate user needs; detect available bandwidths and frequencies then seamlessly connect vehicles, infrastructures, and consumer devices; and it will support the Department of Transportation IntelliDrive Program, helping researchers, auto manufacturers, and Federal and State officials advance the connectivity of US transportation systems for improved safety, mobility, and environmental conditions. Using cognitive radio, a commercial vehicle will know its driver, onboard freight and destination route. Drivers will save time and resources communicating with automatic toll booths and know ahead of time whether to stop at a weigh station or keep rolling. At accident scenes, cognitive radio sensors on freight and transportation modes can alert emergency personnel and measure on-site, real-time conditions such as a chemical leak. The sensors will connect freight to industry, relaying shipment conditions and new delivery schedules. For industry or military purposes, cognitive radio will enable real-time freight tracking around the globe and its sensory technology can help prevent cargo theft or tampering by alerting shipper and receiver if freight is tampered with while en route. For the average consumer, a vehicle will tailor the transportation experience to the passenger such as delivering age-appropriate movies via satellite. Cognitive radio will enhance transportation safety by continually sensing what is important to the user adapting to its environment and incoming information, and proposing solutions that improve mobility and quality of life.

  1. Building a Communication, Education, an Outreach Program for the ShakeAlert National Earthquake Early Warning Program - Recommendations for Public Alerts Via Cell Phones

    NASA Astrophysics Data System (ADS)

    DeGroot, R. M.; Long, K.; Strauss, J. A.

    2017-12-01

    The United States Geological Survey (USGS) and its partners are developing the ShakeAlert Earthquake Early Warning System for the West Coast of the United States. To be an integral part of successful implementation, ShakeAlert engagement programs and materials must integrate with and leverage broader earthquake risk programs. New methods and products for dissemination must be multidisciplinary, cost effective, and consistent with existing hazards education and communication efforts. The ShakeAlert Joint Committee for Communication, Education, and Outreach (JCCEO), is identifying, developing, and cultivating partnerships with ShakeAlert stakeholders including Federal, State, academic partners, private companies, policy makers, and local organizations. Efforts include developing materials, methods for delivery, and reaching stakeholders with information on ShakeAlert, earthquake preparedness, and emergency protective actions. It is essential to develop standards to ensure information communicated via the alerts is consistent across the public and private sector and achieving a common understanding of what actions users take when they receive a ShakeAlert warning. In February 2017, the JCCEO convened the Warning Message Focus Group (WMFG) to provide findings and recommendations to the Alliance for Telecommunications Industry Solutions on the use of earthquake early warning message content standards for public alerts via cell phones. The WMFG represents communications, education, and outreach stakeholders from various sectors including ShakeAlert regional coordinators, industry, emergency managers, and subject matter experts from the social sciences. The group knowledge was combined with an in-depth literature review to ensure that all groups who could receive the message would be taken into account. The USGS and the participating states and agencies acknowledge that the implementation of ShakeAlert is a collective effort requiring the participation of hundreds of stakeholders committed to ensuring public accessibility.

  2. Real time alert system: a disease management system leveraging health information exchange.

    PubMed

    Anand, Vibha; Sheley, Meena E; Xu, Shawn; Downs, Stephen M

    2012-01-01

    Rates of preventive and disease management services can be improved by providing automated alerts and reminders to primary care providers (PCPs) using of health information technology (HIT) tools. Using Adaptive Turnaround Documents (ATAD), an existing Health Information Exchange (HIE) infrastructure and office fax machines, we developed a Real Time Alert (RTA) system. RTA is a computerized decision support system (CDSS) that is able to deliver alerts to PCPs statewide for recommended services around the time of the patient visit. RTA is also able to capture structured clinical data from providers using existing fax technology. In this study, we evaluate RTA's performance for alerting PCPs when their patients with asthma have an emergency room visit anywhere in the state. Our results show that RTA was successfully able to deliver "just in time" patient-relevant alerts to PCPs across the state. Furthermore, of those ATADs faxed back and automatically interpreted by the RTA system, 35% reported finding the provided information helpful. The PCPs who reported finding information helpful also reported making a phone call, sending a letter or seeing the patient for follow up care. We have successfully demonstrated the feasibility of electronically exchanging important patient related information with the PCPs statewide. This is despite a lack of a link with their electronic health records. We have shown that using our ATAD technology, a PCP can be notified quickly of an important event such as a patient's asthma related emergency room admission so further follow up can happen in near real time.

  3. Application of mobile phone technology for managing chemotherapy-associated side-effects.

    PubMed

    Weaver, A; Young, A M; Rowntree, J; Townsend, N; Pearson, S; Smith, J; Gibson, O; Cobern, W; Larsen, M; Tarassenko, L

    2007-11-01

    Novel mobile phone technology linked to a server that communicates patients' symptoms to healthcare professionals has been adapted to register the side- effects of chemotherapy and provide advice on management of toxicity. We report a feasibility study to examine the utility of home monitoring of patients' symptoms via a mobile phone. Six colon cancer patients receiving adjuvant chemotherapy, entered symptom data onto user friendly screens on a mobile phone twice daily. This 'real time' self assessment of nausea, vomiting, mucositis, diarrhoea and hand-foot syndrome and measurement of temperature was sent via a secured connection to a remote computer. In the event of moderate or severe symptoms (generating amber and red alerts respectively), the nurse was immediately alerted by the computer, via a pager. The nurse then contacted the patient to reinforce the automatic advice sent to the patient on their phone and to assess the patient using clinical algorithms. The patient used the mobile phones during the first two cycles of chemotherapy. The data were successfully analysed by the server software and alerts were generated alerting the study nurses to patients' symptoms at the appropriate time. There were 91 alerts-54 red and 37 amber; 54% (29/54) of the red alerts were data delay and transmission problems which were swiftly rectified. The remaining red alerts were managed appropriately by the study nurses. Both patients and staff felt confident in this approach to symptom management. This study demonstrates that the technology for monitoring patients' symptoms worked well. The patients felt secure in the knowledge that their symptoms were being closely monitored and that they were participating effectively in their own care management.

  4. Real Time Alert System: A Disease Management System Leveraging Health Information Exchange

    PubMed Central

    Anand, Vibha; Sheley, Meena E.; Xu, Shawn; Downs, Stephen M.

    2012-01-01

    Background Rates of preventive and disease management services can be improved by providing automated alerts and reminders to primary care providers (PCPs) using of health information technology (HIT) tools. Methods: Using Adaptive Turnaround Documents (ATAD), an existing Health Information Exchange (HIE) infrastructure and office fax machines, we developed a Real Time Alert (RTA) system. RTA is a computerized decision support system (CDSS) that is able to deliver alerts to PCPs statewide for recommended services around the time of the patient visit. RTA is also able to capture structured clinical data from providers using existing fax technology. In this study, we evaluate RTA’s performance for alerting PCPs when their patients with asthma have an emergency room visit anywhere in the state. Results: Our results show that RTA was successfully able to deliver “just in time” patient-relevant alerts to PCPs across the state. Furthermore, of those ATADs faxed back and automatically interpreted by the RTA system, 35% reported finding the provided information helpful. The PCPs who reported finding information helpful also reported making a phone call, sending a letter or seeing the patient for follow up care. Conclusions: We have successfully demonstrated the feasibility of electronically exchanging important patient related information with the PCPs statewide. This is despite a lack of a link with their electronic health records. We have shown that using our ATAD technology, a PCP can be notified quickly of an important event such as a patient’s asthma related emergency room admission so further follow up can happen in near real time. PMID:23569648

  5. PEER News Alerts | PEER News

    Science.gov Websites

    Email Address * First Name * Last Name * Title * Organization * Organization Type * Federal Government State Government Local Government Research Center Testing Lab Non-profit Earthquake Organization For

  6. Vehicle proximity alert system for highway-railroad grade crossings-prototype research

    DOT National Transportation Integrated Search

    2001-04-01

    This report describes testing of prototype vehicle proximity alert system (VPAS) technologies, and presents and evaluates the results. The object was to determine the feasibility of VPAS for possible use in priority vehicles (i.e., emergency vehicles...

  7. The Low-Level Wind Shear Alert System (LLWSAS)

    DTIC Science & Technology

    1980-05-01

    ALERT SYSTEM (LLWSAS). (May R.. a.-ol - 8..’P" Imng Organization Report No, 9, Perfo~ring Or~ni-otlon Ro-r. -andAddress 10. Work Unit No. (TRAIS) Federal...rather than electronic approach. The 2-minute average adheres to recommended International Civil Aviation Organization (ICAO) standards (referernce 14...speed of 140 knots. **Cold front. 80 ’ # 90 0 STRONG CASES: COFF , 1975 80 9STRONG CASES: UNPU1BLISHED 70 60 A STRONG CASES: COFF , et al., 1978 50 \\ 50 -0

  8. Alert management for home healthcare based on home automation analysis.

    PubMed

    Truong, T T; de Lamotte, F; Diguet, J-Ph; Said-Hocine, F

    2010-01-01

    Rising healthcare for elder and disabled people can be controlled by offering people autonomy at home by means of information technology. In this paper, we present an original and sensorless alert management solution which performs multimedia and home automation service discrimination and extracts highly regular home activities as sensors for alert management. The results of simulation data, based on real context, allow us to evaluate our approach before application to real data.

  9. Cognitive Radio will revolutionize American transportation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Cognitive Radio will revolutionize American transportation. Through smart technology, it will anticipate user needs; detect available bandwidths and frequencies then seamlessly connect vehicles, infrastructures, and consumer devices; and it will support the Department of Transportation IntelliDrive Program, helping researchers, auto manufacturers, and Federal and State officials advance the connectivity of US transportation systems for improved safety, mobility, and environmental conditions. Using cognitive radio, a commercial vehicle will know its driver, onboard freight and destination route. Drivers will save time and resources communicating with automatic toll booths and know ahead of time whether to stop at a weigh station or keepmore » rolling. At accident scenes, cognitive radio sensors on freight and transportation modes can alert emergency personnel and measure on-site, real-time conditions such as a chemical leak. The sensors will connect freight to industry, relaying shipment conditions and new delivery schedules. For industry or military purposes, cognitive radio will enable real-time freight tracking around the globe and its sensory technology can help prevent cargo theft or tampering by alerting shipper and receiver if freight is tampered with while en route. For the average consumer, a vehicle will tailor the transportation experience to the passenger such as delivering age-appropriate movies via satellite. Cognitive radio will enhance transportation safety by continually sensing what is important to the user adapting to its environment and incoming information, and proposing solutions that improve mobility and quality of life.« less

  10. Evaluation of Antimicrobial Stewardship-Related Alerts Using a Clinical Decision Support System.

    PubMed

    Ghamrawi, Riane J; Kantorovich, Alexander; Bauer, Seth R; Pallotta, Andrea M; Sekeres, Jennifer K; Gordon, Steven M; Neuner, Elizabeth A

    2017-11-01

    Background: Information technology, including clinical decision support systems (CDSS), have an increasingly important and growing role in identifying opportunities for antimicrobial stewardship-related interventions. Objective: The aim of this study was to describe and compare types and outcomes of CDSS-built antimicrobial stewardship alerts. Methods: Fifteen alerts were evaluated in the initial antimicrobial stewardship program (ASP) review. Preimplementation, alerts were reviewed retrospectively. Postimplementation, alerts were reviewed in real-time. Data collection included total number of actionable alerts, recommendation acceptance rates, and time spent on each alert. Time to de-escalation to narrower spectrum agents was collected. Results: In total, 749 alerts were evaluated. Overall, 306 (41%) alerts were actionable (173 preimplementation, 133 postimplementation). Rates of actionable alerts were similar for custom-built and prebuilt alert types (39% [53 of 135] vs 41% [253 of 614], P = .68]. In the postimplementation group, an intervention was attempted in 97% of actionable alerts and 70% of interventions were accepted. The median time spent per alert was 7 minutes (interquartile range [IQR], 5-13 minutes; 15 [12-17] minutes for actionable alerts vs 6 [5-7] minutes for nonactionable alerts, P < .001). In cases where the antimicrobial was eventually de-escalated, the median time to de-escalation was 28.8 hours (95% confidence interval [CI], 10.0-69.1 hours) preimplementation vs 4.7 hours (95% CI, 2.4-22.1 hours) postimplementation, P < .001. Conclusions: CDSS have played an important role in ASPs to help identify opportunities to optimize antimicrobial use through prebuilt and custom-built alerts. As ASP roles continue to expand, focusing time on customizing institution specific alerts will be of vital importance to help redistribute time needed to manage other ASP tasks and opportunities.

  11. Technologic Distractions (Part 1): Summary of Approaches to Manage Alert Quantity With Intent to Reduce Alert Fatigue and Suggestions for Alert Fatigue Metrics.

    PubMed

    Kane-Gill, Sandra L; O'Connor, Michael F; Rothschild, Jeffrey M; Selby, Nicholas M; McLean, Barbara; Bonafide, Christopher P; Cvach, Maria M; Hu, Xiao; Konkani, Avinash; Pelter, Michele M; Winters, Bradford D

    2017-09-01

    To provide ICU clinicians with evidence-based guidance on tested interventions that reduce or prevent alert fatigue within clinical decision support systems. Systematic review of PubMed, Embase, SCOPUS, and CINAHL for relevant literature from 1966 to February 2017. Focus on critically ill patients and included evaluations in other patient care settings, as well. Identified interventions designed to reduce or prevent alert fatigue within clinical decision support systems. Study selection was based on one primary key question to identify effective interventions that attempted to reduce alert fatigue and three secondary key questions that covered the negative effects of alert fatigue, potential unintended consequences of efforts to reduce alert fatigue, and ideal alert quantity. Data were abstracted by two reviewers independently using a standardized abstraction tool. Surveys, meeting abstracts, "gray" literature, studies not available in English, and studies with non-original data were excluded. For the primary key question, articles were excluded if they did not provide a comparator as key question 1 was designed as a problem, intervention, comparison, and outcome question. We anticipated that reduction in alert fatigue, including the concept of desensitization may not be directly measured and thus considered interventions that reduced alert quantity as a surrogate marker for alert fatigue. Twenty-six articles met the inclusion criteria. Approaches for managing alert fatigue in the ICU are provided as a result of reviewing tested interventions that reduced alert quantity with the anticipated effect of reducing fatigue. Suggested alert management strategies include prioritizing alerts, developing sophisticated alerts, customizing commercially available alerts, and including end user opinion in alert selection. Alert fatigue itself is studied less frequently, as an outcome, and there is a need for more precise evaluation. Standardized metrics for alert fatigue is needed to advance the field. Suggestions for standardized metrics are provided in this document.

  12. NASA aviation safety reporting system

    NASA Technical Reports Server (NTRS)

    1978-01-01

    An analytical study of reports relating to cockpit altitude alert systems was performed. A recent change in the Federal Air Regulation permits the system to be modified so that the alerting signal approaching altitude has only a visual component; the auditory signal would continue to be heard if a deviation from an assigned altitude occurred. Failure to observe altitude alert signals and failure to reset the system were the commonest cause of altitude deviations related to this system. Cockpit crew distraction was the most frequent reason for these failures. It was noted by numerous reporters that the presence of altitude alert system made them less aware of altitude; this lack of altitude awareness is discussed. Failures of crew coordination were also noted. It is suggested that although modification of the altitude alert system may be highly desirable in short-haul aircraft, it may not be desirable for long-haul aircraft in which cockpit workloads are much lower for long periods of time. In these cockpits, the aural alert approaching altitudes is perceived as useful and helpful. If the systems are to be modified, it appears that additional emphasis on altitude awareness during recurrent training will be necessary; it is also possible that flight crew operating procedures during climb and descent may need examination with respect to monitoring responsibilities. A selection of alert bulletins and responses to them is presented.

  13. Federal Trade Commission

    MedlinePlus

    ... a Consumer Complaint Report Identity Theft Get Your Free Credit Report Register for Do Not Call Get Scam Alerts ... File a claim if you were scammed via money transfer Ed tech, Privacy Workshop FTC, Department of ...

  14. Executable Architectures for Modeling Command and Control Processes

    DTIC Science & Technology

    2006-06-01

    of introducing new NCES capabilities (such as the Federated Search ) to the ‘To Be’ model. 2 Table of Contents 1 INTRODUCTION...Conventional Method for SME Discovery ToBe.JCAS.3.2 Send Alert and/or Request OR AND ToBe.JCAS.3.4 Employ Federated Search for CAS-related Info JCAS.1.3.6.13...instant messaging, web browser, etc. • Federated Search – this capability provides a way to search enterprise contents across various search-enabled

  15. Evaluation of growth based rapid microbiological methods for sterility testing of vaccines and other biological products.

    PubMed

    Parveen, Seema; Kaur, Simleen; David, Selwyn A Wilson; Kenney, James L; McCormick, William M; Gupta, Rajesh K

    2011-10-19

    Most biological products, including vaccines, administered by the parenteral route are required to be tested for sterility at the final container and also at various stages during manufacture. The sterility testing method described in the Code of Federal Regulations (21 CFR 610.12) and the United States Pharmacopoeia (USP, Chapter <71>) is based on the observation of turbidity in liquid culture media due to growth of potential contaminants. We evaluated rapid microbiological methods (RMM) based on detection of growth 1) by adenosine triphosphate (ATP) bioluminescence technology (Rapid Milliflex(®) Detection System [RMDS]), and 2) by CO(2) monitoring technologies (BacT/Alert and the BACTEC systems), as alternate sterility methods. Microorganisms representing Gram negative, Gram positive, aerobic, anaerobic, spore forming, slow growing bacteria, yeast, and fungi were prepared in aliquots of Fluid A or a biological matrix (including inactivated influenza vaccines) to contain approximately 0.1, 1, 10 and 100 colony forming units (CFU) in an inoculum of 10 ml. These preparations were inoculated to the specific media required for the various methods: 1) fluid thioglycollate medium (FTM) and tryptic soy broth (TSB) of the compendial sterility method (both membrane filtration and direct inoculation); 2) tryptic soy agar (TSA), Sabouraud dextrose agar (SDA) and Schaedler blood agar (SBA) of the RMDS; 3) iAST and iNST media of the BacT/Alert system and 4) Standard 10 Aerobic/F and Standard Anaerobic/F media of the BACTEC system. RMDS was significantly more sensitive in detecting various microorganisms at 0.1CFU than the compendial methods (p<0.05), whereas the compendial membrane filtration method was significantly more sensitive than the BACTEC and BacT/Alert methods (p<0.05). RMDS detected all microorganisms significantly faster than the compendial method (p<0.05). BacT/Alert and BACTEC methods detected most microorganisms significantly faster than the compendial method (p<0.05), but took almost the same time to detect the slow growing microorganism P. acnes, compared to the compendial method. RMDS using SBA detected all test microorganisms in the presence of a matrix containing preservative 0.01% thimerosal, whereas the BacT/Alert and BACTEC systems did not consistently detect all the test microorganisms in the presence of 0.01% thimerosal. RMDS was compatible with inactivated influenza vaccines and aluminum phosphate or aluminum hydroxide adjuvants at up to 8 mg/ml without any interference in bioluminescence. RMDS was shown to be acceptable as an alternate sterility method taking 5 days as compared to the 14 days required of the compendial method. Isolation of microorganisms from the RMDS was accomplished by re-incubation of membranes with fresh SBA medium and microbial identification was confirmed using the MicroSEQ Identification System. BacT/Alert and BACTEC systems may be applicable as alternate methods to the compendial direct inoculation sterility method for products that do not contain preservatives or anti-microbial agents. Published by Elsevier Ltd.

  16. PleurAlert: an augmented chest drainage system with electronic sensing, automated alerts and internet connectivity.

    PubMed

    Leeson, Cory E; Weaver, Robert A; Bissell, Taylor; Hoyer, Rachel; McClain, Corinne; Nelson, Douglas A; Samosky, Joseph T

    2012-01-01

    We have enhanced a common medical device, the chest tube drainage container, with electronic sensing of fluid volume, automated detection of critical alarm conditions and the ability to automatically send alert text messages to a nurse's cell phone. The PleurAlert system provides a simple touch-screen interface and can graphically display chest tube output over time. Our design augments a device whose basic function dates back 50 years by adding technology to automate and optimize a monitoring process that can be time consuming and inconvenient for nurses. The system may also enhance detection of emergency conditions and speed response time.

  17. Tsunami.gov: NOAA's Tsunami Information Portal

    NASA Astrophysics Data System (ADS)

    Shiro, B.; Carrick, J.; Hellman, S. B.; Bernard, M.; Dildine, W. P.

    2014-12-01

    We present the new Tsunami.gov website, which delivers a single authoritative source of tsunami information for the public and emergency management communities. The site efficiently merges information from NOAA's Tsunami Warning Centers (TWC's) by way of a comprehensive XML feed called Tsunami Event XML (TEX). The resulting unified view allows users to quickly see the latest tsunami alert status in geographic context without having to understand complex TWC areas of responsibility. The new site provides for the creation of a wide range of products beyond the traditional ASCII-based tsunami messages. The publication of modern formats such as Common Alerting Protocol (CAP) can drive geographically aware emergency alert systems like FEMA's Integrated Public Alert and Warning System (IPAWS). Supported are other popular information delivery systems, including email, text messaging, and social media updates. The Tsunami.gov portal allows NOAA staff to easily edit content and provides the facility for users to customize their viewing experience. In addition to access by the public, emergency managers and government officials may be offered the capability to log into the portal for special access rights to decision-making and administrative resources relevant to their respective tsunami warning systems. The site follows modern HTML5 responsive design practices for optimized use on mobile as well as non-mobile platforms. It meets all federal security and accessibility standards. Moving forward, we hope to expand Tsunami.gov to encompass tsunami-related content currently offered on separate websites, including the NOAA Tsunami Website, National Tsunami Hazard Mitigation Program, NOAA Center for Tsunami Research, National Geophysical Data Center's Tsunami Database, and National Data Buoy Center's DART Program. This project is part of the larger Tsunami Information Technology Modernization Project, which is consolidating the software architectures of NOAA's existing TWC's into a single system. We welcome your feedback to help Tsunami.gov become an effective public resource for tsunami information and a medium to enable better global tsunami warning coordination.

  18. Functional Requirements for the Next Generation of Mass Notification

    ERIC Educational Resources Information Center

    Trumbo, Berkly

    2012-01-01

    While the latest update to National Fire Protection Association (NFPA) redefines mass notification as "emergency communications systems" (ECS), the end user community is formulating expectations related to the future functionality of today's alerting solutions. Numerous best practices have surfaced since alerting technology began its rapid,…

  19. Status of Public Earthquake Early Warning in the U.S

    NASA Astrophysics Data System (ADS)

    Given, D. D.

    2013-12-01

    Earthquake Early Warning (EEW) is a proven use of seismological science that can give people and businesses outside the epicentral area of a large earthquake up to a minute to take protective actions before the most destructive shaking hits them. Since 2006 several organizations have been collaborating to create such a system in the United States. These groups include the US Geological Survey, Caltech, UC Berkeley, the University of Washington, the Southern California Earthquake Center, the Swiss Federal Institute of Technology, Zürich, the California Office of Emergency Services, and the California Geological Survey. A demonstration version of the system, called ShakeAlert, began sending test notifications to selected users in California in January 2012. In August 2012 San Francisco's Bay Area Rapid Transit district began slowing and stopping trains in response to strong ground shaking. The next step in the project is to progress to a production prototype for the west coast. The system is built on top of the considerable technical and organizational earthquake monitoring infrastructure of the Advanced National Seismic System (ANSS). While a fully functional, robust, public EEW system will require significant new investment and development in several major areas, modest progress is being made with current resources. First, high-quality sensors must be installed with sufficient density, particularly near source faults. Where possible, we are upgrading and augmenting the existing ANSS networks on the west coast. Second, data telemetry from those sensors must be engineered for speed and reliability. Next, robust central processing infrastructure is being designed and built. Also, computer algorithms to detect and characterize the evolving earthquake must be further developed and tested. Last year the Gordon and Betty Moore Foundation funded USGS, Caltech, UCB and UW to accelerate R&D efforts. Every available means of distributing alerts must be used to insure the system's effectiveness. We have developed an internet-based UserDisplay application and a smartphone app based on Google Cloud Messaging. In addition, USGS has applied for authorization to alert over FEMA's Integrated Pubic Alert and Warning System. We are also working with private companies to develop alert distribution channels and end user implementation capabilities. Finally, because policy makers, institutional users, and the public must be educated about the system, social scientists and communicators are determining how to communicate the alerts most effectively. Progress is also being made in several related areas. Real-time GPS position data is becoming available on a large scale and algorithms are being developed to use these data to rapidly characterize the fault rupture as it propagates. New, advanced seismological and geodetic algorithms for the Cascadia megathrust and San Andreas fault are being developed. We are exploring public-private partnerships to develop commercial EEW applications. And Federal, State and local agencies are working out their roles and responsibilities in building, operating and educating users about the system. There is much more to be done and funding the creation and operation of this new capability is a challenge in the current budget climate. However, our goal is to build an EEW system before the next big earthquake rather than in its aftermath.

  20. Innovative Software Tools Measure Behavioral Alertness

    NASA Technical Reports Server (NTRS)

    2014-01-01

    To monitor astronaut behavioral alertness in space, Johnson Space Center awarded Philadelphia-based Pulsar Informatics Inc. SBIR funding to develop software to be used onboard the International Space Station. Now used by the government and private companies, the technology has increased revenues for the firm by an average of 75 percent every year.

  1. Developing, Implementing, and Assessing an Early Alert System

    ERIC Educational Resources Information Center

    Tampke, Dale R.

    2013-01-01

    Early alert systems offer institutions systematic approaches to identifying and intervening with students exhibiting at-risk behaviors. Many of these systems rely on a common format for student referral to central receiving point. Systems at larger institutions often use web-based technology to allow for a scalable (available campus wide) approach…

  2. 47 CFR 10.540 - Attestation requirement. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Attestation requirement. [Reserved] 10.540 Section 10.540 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Equipment Requirements § 10.540 Attestation requirement. [Reserved] ...

  3. 77 FR 65880 - Information Collections Being Reviewed by the Federal Communications Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-31

    ... of the functions of the Commission, including whether the information shall have practical utility..., Leased Access; 76.1711, Emergency Alert System (EAS) Tests and Activation. Form Number: N/A. Type of...

  4. A CCTV system with SMS alert (CMDSA): An implementation of pixel processing algorithm for motion detection

    NASA Astrophysics Data System (ADS)

    Rahman, Nurul Hidayah Ab; Abdullah, Nurul Azma; Hamid, Isredza Rahmi A.; Wen, Chuah Chai; Jelani, Mohamad Shafiqur Rahman Mohd

    2017-10-01

    Closed-Circuit TV (CCTV) system is one of the technologies in surveillance field to solve the problem of detection and monitoring by providing extra features such as email alert or motion detection. However, detecting and alerting the admin on CCTV system may complicate due to the complexity to integrate the main program with an external Application Programming Interface (API). In this study, pixel processing algorithm is applied due to its efficiency and SMS alert is added as an alternative solution for users who opted out email alert system or have no Internet connection. A CCTV system with SMS alert (CMDSA) was developed using evolutionary prototyping methodology. The system interface was implemented using Microsoft Visual Studio while the backend components, which are database and coding, were implemented on SQLite database and C# programming language, respectively. The main modules of CMDSA are motion detection, capturing and saving video, image processing and Short Message Service (SMS) alert functions. Subsequently, the system is able to reduce the processing time making the detection process become faster, reduce the space and memory used to run the program and alerting the system admin instantly.

  5. Modeling Pilot State in Next Generation Aircraft Alert Systems

    NASA Technical Reports Server (NTRS)

    Carlin, Alan S.; Alexander, Amy L.; Schurr, Nathan

    2011-01-01

    The Next Generation Air Transportation System will introduce new, advanced sensor technologies into the cockpit that must convey a large number of potentially complex alerts. Our work focuses on the challenges associated with prioritizing aircraft sensor alerts in a quick and efficient manner, essentially determining when and how to alert the pilot This "alert decision" becomes very difficult in NextGen due to the following challenges: 1) the increasing number of potential hazards, 2) the uncertainty associated with the state of potential hazards as well as pilot slate , and 3) the limited time to make safely-critical decisions. In this paper, we focus on pilot state and present a model for anticipating duration and quality of pilot behavior, for use in a larger system which issues aircraft alerts. We estimate pilot workload, which we model as being dependent on factors including mental effort, task demands. and task performance. We perform a mathematically rigorous analysis of the model and resulting alerting plans. We simulate the model in software and present simulated results with respect to manipulation of the pilot measures.

  6. USGS Earthquake Program GPS Use Case : Earthquake Early Warning

    DOT National Transportation Integrated Search

    2015-03-12

    USGS GPS receiver use case. Item 1 - High Precision User (federal agency with Stafford Act hazard alert responsibilities for earthquakes, volcanoes and landslides nationwide). Item 2 - Description of Associated GPS Application(s): The USGS Eart...

  7. Use of auxiliary external alerting devices to improve locomotive conspicuity

    DOT National Transportation Integrated Search

    1995-07-01

    Historically, highway-railroad grade crossings have represented a major hazard to motor vehicle drivers. The Federal Railroad Administration (FRA), U.S. Department of Transportation (USDOT) has initiated a comprehensive research program to address gr...

  8. Results of DATAS Investigation of ATCRBS Environment at Los Angeles International Airport

    DOT National Transportation Integrated Search

    1993-04-01

    Federal Aviation Administration (FAA) Technical Center Data Link project : personnel designed, developed, and deployed a system to record Traffic Alert : and Collision Avoidance System (TCAS) activity. Through coordinated efforts with : TCAS project ...

  9. V-Alert: Description and Validation of a Vulnerable Road User Alert System in the Framework of a Smart City.

    PubMed

    Hernandez-Jayo, Unai; De-la-Iglesia, Idoia; Perez, Jagoba

    2015-07-29

    V-Alert is a cooperative application to be deployed in the frame of Smart Cities with the aim of reducing the probability of accidents involving Vulnerable Road Users (VRU) and vehicles. The architecture of V-Alert combines short- and long-range communication technologies in order to provide more time to the drivers and VRU to take the appropriate maneuver and avoid a possible collision. The information generated by mobile sensors (vehicles and cyclists) is sent over this heterogeneous communication architecture and processed in a central server, the Drivers Cloud, which is in charge of generating the messages that are shown on the drivers' and cyclists' Human Machine Interface (HMI). First of all, V-Alert has been tested in a simulated scenario to check the communications architecture in a complex scenario and, once it was validated, all the elements of V-Alert have been moved to a real scenario to check the application reliability. All the results are shown along the length of this paper.

  10. 47 CFR 11.11 - The Emergency Alert System (EAS).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... through the use of a single set of EAS equipment at the hub station (or common studio or control point... the FCC in any agreements. (e) Other technologies and public service providers, such as low earth... 47 Telecommunication 1 2014-10-01 2014-10-01 false The Emergency Alert System (EAS). 11.11 Section...

  11. 47 CFR 11.11 - The Emergency Alert System (EAS).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... through the use of a single set of EAS equipment at the hub station (or common studio or control point... the FCC in any agreements. (e) Other technologies and public service providers, such as low earth... 47 Telecommunication 1 2013-10-01 2013-10-01 false The Emergency Alert System (EAS). 11.11 Section...

  12. 47 CFR 11.11 - The Emergency Alert System (EAS).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... through the use of a single set of EAS equipment at the hub station (or common studio or control point... the FCC in any agreements. (e) Other technologies and public service providers, such as low earth... 47 Telecommunication 1 2012-10-01 2012-10-01 false The Emergency Alert System (EAS). 11.11 Section...

  13. Unmanned Aircraft Systems Human-in-the-Loop Controller and Pilot Acceptability Study: Collision Avoidance, Self-Separation, and Alerting Times (CASSAT)

    NASA Technical Reports Server (NTRS)

    Comstock, James R., Jr.; Ghatas, Rania W.; Vincent, Michael J.; Consiglio, Maria C.; Munoz, Cesar; Chamberlain, James P.; Volk, Paul; Arthur, Keith E.

    2016-01-01

    The Federal Aviation Administration (FAA) has been mandated by the Congressional funding bill of 2012 to open the National Airspace System (NAS) to Unmanned Aircraft Systems (UAS). With the growing use of unmanned systems, NASA has established a multi-center "UAS Integration in the NAS" Project, in collaboration with the FAA and industry, and is guiding its research efforts to look at and examine crucial safety concerns regarding the integration of UAS into the NAS. Key research efforts are addressing requirements for detect-and-avoid (DAA), self-separation (SS), and collision avoidance (CA) technologies. In one of a series of human-in-the-loop experiments, NASA Langley Research Center set up a study known as Collision Avoidance, Self-Separation, and Alerting Times (CASSAT). The first phase assessed active air traffic controller interactions with DAA systems and the second phase examined reactions to the DAA system and displays by UAS Pilots at a simulated ground control station (GCS). Analyses of the test results from Phase I and Phase II are presented in this paper. Results from the CASSAT study and previous human-in-the-loop experiments will play a crucial role in the FAA's establishment of rules, regulations, and procedures to safely, efficiently, and effectively integrate UAS into the NAS.

  14. An Analysis of Federal Airport and Air Carrier Employee Access Control, Screening. and Training Regulations

    DTIC Science & Technology

    1998-03-01

    traveling public, air carriers, and persons employed by or conducting business at public airports. 14. SUBJECT TERMS Airport Security , Federal...26 4. Sterile Area 28 5. Exclusive Area 28 E. SECURITY ALERT LEVELS 29 F. AIRPORT SECURITY TOOLS 30 1. Electronic Detection System 31 a... Security Coordinator ASP Airport Security Program BIS Biometrie Identification System CCTV Closed Circuit Television CJIS Criminal Justice Information

  15. Massachusetts wants a tougher federal oil spill control plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Massachusetts wants a tougher federal oil spill control plan and has petitioned the U.S. Council on Environmental Quality (CEQ). The present oil spill contingency plan is inadequate, according to M. Dukakis (Gov. Mass.). The Massachusetts plan, which CEQ officials view favorably, would extend responsibility to the 200 mi fishing limit, provide for protection of birds, and set up an oil strike force on 24 hr alert.

  16. 47 CFR 10.330 - Provider infrastructure requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Provider infrastructure requirements. 10.330 Section 10.330 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.330 Provider infrastructure requirements. This section specifies the general...

  17. 47 CFR 10.330 - Provider infrastructure requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Provider infrastructure requirements. 10.330 Section 10.330 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.330 Provider infrastructure requirements. This section specifies the general...

  18. 47 CFR 10.330 - Provider infrastructure requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Provider infrastructure requirements. 10.330 Section 10.330 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.330 Provider infrastructure requirements. This section specifies the general...

  19. 47 CFR 10.330 - Provider infrastructure requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Provider infrastructure requirements. 10.330 Section 10.330 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.330 Provider infrastructure requirements. This section specifies the general...

  20. 47 CFR 10.330 - Provider infrastructure requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Provider infrastructure requirements. 10.330 Section 10.330 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.330 Provider infrastructure requirements. This section specifies the general...

  1. Dual-task performance consequences of imperfect alerting associated with a cockpit display of traffic information.

    PubMed

    Wickens, Christopher; Colcombe, Angela

    2007-10-01

    Performance consequences related to integrating an imperfect alert within a complex task domain were examined in two experiments. Cockpit displays of traffic information (CDTIs) are being designed for use in airplane cockpits as responsibility for safe separation becomes shared between pilots and controllers. Of interest in this work is how characteristics of the alarm system such as threshold, modality, and number of alert levels impact concurrent task (flight control) performance and response to potential conflicts. Student pilots performed a tracking task analogous to flight control while simultaneously monitoring for air traffic conflicts with the aid of a CDTI alert as the threshold, modality, and level of alert was varied. As the alerting system became more prone to false alerts, pilot compliance decreased and concurrent performance improved. There was some evidence of auditory preemption with auditory alerts as the false alarm rate increased. Finally, there was no benefit to a three-level system over a two-level system. There is justification for increased false alarm rates, as miss-prone systems appear to be costly. The 4:1 false alarm to miss ratio employed here improved accuracy and concurrent task performance. More research needs to address the potential benefits of likelihood alerting. The issues addressed in this research can be applied to any imperfect alerting system such as in aviation, driving, or air traffic control. It is crucial to understand the performance consequences of new technology and the efficacy of potential mitigating design features within the specific context desired.

  2. Human Factors Evaluation of Conflict Detection Tool for Terminal Area

    NASA Technical Reports Server (NTRS)

    Verma, Savita Arora; Tang, Huabin; Ballinger, Deborah; Chinn, Fay Cherie; Kozon, Thomas E.

    2013-01-01

    A conflict detection and resolution tool, Terminal-area Tactical Separation-Assured Flight Environment (T-TSAFE), is being developed to improve the timeliness and accuracy of alerts and reduce the false alert rate observed with the currently deployed technology. The legacy system in use today, Conflict Alert, relies primarily on a dead reckoning algorithm, whereas T-TSAFE uses intent information to augment dead reckoning. In previous experiments, T-TSAFE was found to reduce the rate of false alerts and increase time between the alert to the controller and a loss of separation over the legacy system. In the present study, T-TSAFE was tested under two meteorological conditions, 1) all aircraft operated under instrument flight regimen, and 2) some aircraft operated under mixed operating conditions. The tool was used to visually alert controllers to predicted Losses of separation throughout the terminal airspace, and show compression errors, on final approach. The performance of T-TSAFE on final approach was compared with Automated Terminal Proximity Alert (ATPA), a tool recently deployed by the FAA. Results show that controllers did not report differences in workload or situational awareness between the T-TSAFE and ATPA cones but did prefer T-TSAFE features over ATPA functionality. T-TSAFE will provide one tool that shows alerts in the data blocks and compression errors via cones on the final approach, implementing all tactical conflict detection and alerting via one tool in TRACON airspace.

  3. Alert!: In Emergencies, Schools Use Technology to Get the Message out Quickly

    ERIC Educational Resources Information Center

    Violino, Bob

    2008-01-01

    This article describes how a growing number of community colleges have begun deploying emergency alert systems that can be used to send information via e-mail and text messaging directly to students' cell phones and other portable devices. Such systems enable authorized campus administrators to send messages to thousands of people within minutes.…

  4. Pilot evaluation of a method to assess prescribers' information processing of medication alerts.

    PubMed

    Russ, Alissa L; Melton, Brittany L; Daggy, Joanne K; Saleem, Jason J

    2017-02-01

    Prescribers commonly receive alerts during medication ordering. Prescribers work in a complex, time-pressured environment; to enhance the effectiveness of safety alerts, the effort needed to cognitively process these alerts should be minimized. Methods to evaluate the extent to which computerized alerts support prescribers' information processing are lacking. To develop a methodological protocol to assess the extent to which alerts support prescribers' information processing at-a-glance; specifically, the incorporation of information into their working memory. We hypothesized that the method would be feasible and that we would be able to detect a significant difference in prescribers' information processing with a revised alert display that incorporates warning design guidelines compared to the original alert display. A counterbalanced, within-subject study was conducted with 20 prescribers in a human-computer interaction laboratory. We tested a single alert that was displayed in two different ways. Prescribers were informed that an alert would appear for 10s. After the alert was shown, a white screen was displayed, and prescribers were asked to verbally describe what they saw; indicate how many total warnings; and describe anything else they remembered about the alert. We measured information processing via the accuracy of prescribers' free recall and their ability to identify that three warning messages were present. Two analysts independently evaluated participants' responses against a comprehensive catalog of alert elements and then discussed discrepancies until reaching consensus. This feasibility study demonstrated that the method seemed to be effective for evaluating prescribers' information processing of medication alert displays. With this method, we were able to detect significant differences in prescribers' recall of alert information. The proportion of total data elements that prescribers were able to accurately recall was significantly greater for the revised versus original alert display (p=0.006). With the revised display, more prescribers accurately reported that three warnings were shown (p=0.002). The methodological protocol was feasible for evaluating the alert display and yielded important findings on prescribers' information processing. Study methods supplement traditional usability evaluation methods and may be useful for evaluating information processing of other healthcare technologies. Published by Elsevier Inc.

  5. Earthquake early Warning ShakeAlert system: West coast wide production prototype

    USGS Publications Warehouse

    Kohler, Monica D.; Cochran, Elizabeth S.; Given, Douglas; Guiwits, Stephen; Neuhauser, Doug; Hensen, Ivan; Hartog, Renate; Bodin, Paul; Kress, Victor; Thompson, Stephen; Felizardo, Claude; Brody, Jeff; Bhadha, Rayo; Schwarz, Stan

    2017-01-01

    Earthquake early warning (EEW) is an application of seismological science that can give people, as well as mechanical and electrical systems, up to tens of seconds to take protective actions before peak earthquake shaking arrives at a location. Since 2006, the U.S. Geological Survey has been working in collaboration with several partners to develop EEW for the United States. The goal is to create and operate an EEW system, called ShakeAlert, for the highest risk areas of the United States, starting with the West Coast states of California, Oregon, and Washington. In early 2016, the Production Prototype v.1.0 was established for California; then, in early 2017, v.1.2 was established for the West Coast, with earthquake notifications being distributed to a group of beta users in California, Oregon, and Washington. The new ShakeAlert Production Prototype was an outgrowth from an earlier demonstration EEW system that began sending test notifications to selected users in California in January 2012. ShakeAlert leverages the considerable physical, technical, and organizational earthquake monitoring infrastructure of the Advanced National Seismic System, a nationwide federation of cooperating seismic networks. When fully implemented, the ShakeAlert system may reduce damage and injury caused by large earthquakes, improve the nation’s resilience, and speed recovery.

  6. 47 CFR 10.340 - Digital television transmission towers retransmission capability.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Digital television transmission towers retransmission capability. 10.340 Section 10.340 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.340 Digital television transmission towers...

  7. 47 CFR 10.340 - Digital television transmission towers retransmission capability.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Digital television transmission towers retransmission capability. 10.340 Section 10.340 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.340 Digital television transmission towers...

  8. 47 CFR 10.340 - Digital television transmission towers retransmission capability.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Digital television transmission towers retransmission capability. 10.340 Section 10.340 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.340 Digital television transmission towers...

  9. 47 CFR 10.340 - Digital television transmission towers retransmission capability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Digital television transmission towers retransmission capability. 10.340 Section 10.340 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.340 Digital television transmission towers...

  10. PRN 94-6: Pesticide Products Registered for Use on Humans to Control Lice (Pediculicides)

    EPA Pesticide Factsheets

    This notice alerts pesticide registrants to a rule issued by Food and Drug Administration (FDA) under the Federal Food, Drug and Cosmetic Act (FFDCA) establishing conditions for safe and effective use of pediculicide drug products.

  11. Beware of Illegally Marketed Diabetes Treatments

    MedlinePlus

    ... exercise program,” Humbert said. Health care professionals and consumers should report any problems or reactions—often referred to as ... Continuing Education Inspections & Compliance Federal, State & Local Officials ... Content Home Latest Recalls Report an Adverse Event MedWatch Safety Alerts News Releases ...

  12. Think Before You Ink: Are Tattoos Safe?

    MedlinePlus

    ... about the ink and your reaction and outcome. Reports from consumers are one of our most important sources of ... Continuing Education Inspections & Compliance Federal, State & Local Officials ... Content Home Latest Recalls Report an Adverse Event MedWatch Safety Alerts News Releases ...

  13. 77 FR 37041 - Information Collection(s) Being Reviewed by the Federal Communications Commission for Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-20

    ... currently valid OMB control number. No person shall be subject to any penalty for failing to comply with a... contains rules and regulations addressing the nation's Emergency Alert System (EAS). The EAS provides the...

  14. V-Alert: Description and Validation of a Vulnerable Road User Alert System in the Framework of a Smart City

    PubMed Central

    Hernandez-Jayo, Unai; De-la-Iglesia, Idoia; Perez, Jagoba

    2015-01-01

    V-Alert is a cooperative application to be deployed in the frame of Smart Cities with the aim of reducing the probability of accidents involving Vulnerable Road Users (VRU) and vehicles. The architecture of V-Alert combines short- and long-range communication technologies in order to provide more time to the drivers and VRU to take the appropriate maneuver and avoid a possible collision. The information generated by mobile sensors (vehicles and cyclists) is sent over this heterogeneous communication architecture and processed in a central server, the Drivers Cloud, which is in charge of generating the messages that are shown on the drivers’ and cyclists’ Human Machine Interface (HMI). First of all, V-Alert has been tested in a simulated scenario to check the communications architecture in a complex scenario and, once it was validated, all the elements of V-Alert have been moved to a real scenario to check the application reliability. All the results are shown along the length of this paper. PMID:26230695

  15. A graphical workstation based part-task flight simulator for preliminary rapid evaluation of advanced displays

    NASA Technical Reports Server (NTRS)

    Wanke, Craig; Kuchar, James; Hahn, Edward; Pritchett, A.; Hansman, R. John

    1994-01-01

    Advances in avionics and display technology are significantly changing the cockpit environment in current transport aircraft. The MIT Aeronautical Systems Lab (ASL) developed a part-task flight simulator specifically to study the effects of these new technologies on flight crew situational awareness and performance. The simulator is based on a commercially-available graphics workstation, and can be rapidly reconfigured to meet the varying demands of experimental studies. The simulator was successfully used to evaluate graphical microbursts alerting displays, electronic instrument approach plates, terrain awareness and alerting displays, and ATC routing amendment delivery through digital datalinks.

  16. Analysis of acoustic data for hybrid and electric vehicles measured on hemi-anechoic chambers

    DOT National Transportation Integrated Search

    2015-04-01

    The Pedestrian Safety Enhancement Act of 2010 requires the National Highway Traffic Safety : Administration to conduct a rulemaking to establish a Federal Motor Vehicle Safety Standard requiring an alert sound for pedestrians to be emitted by electri...

  17. 47 CFR 10.2 - Purpose.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Purpose. 10.2 Section 10.2 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM General Information § 10.2 Purpose. The rules in this part establish the requirements for participation in the voluntary Commercial...

  18. 47 CFR 10.520 - Common audio attention signal.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Common audio attention signal. 10.520 Section 10.520 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Equipment Requirements § 10.520 Common audio attention signal. A Participating CMS Provider and equipment...

  19. 47 CFR 10.530 - Common vibration cadence.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Common vibration cadence. 10.530 Section 10.530 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Equipment Requirements § 10.530 Common vibration cadence. A Participating CMS Provider and equipment manufacturers may only...

  20. 47 CFR 10.510 - Call preemption prohibition.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Call preemption prohibition. 10.510 Section 10.510 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Equipment Requirements § 10.510 Call preemption prohibition. Devices marketed for public use under part 10...

  1. 47 CFR 10.11 - CMAS implementation timeline.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false CMAS implementation timeline. 10.11 Section 10.11 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM General Information § 10.11 CMAS implementation timeline. Notwithstanding anything in this part to the contrary, a...

  2. 47 CFR 10.500 - General requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false General requirements. 10.500 Section 10.500 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM Equipment Requirements § 10.500 General requirements. CMAS mobile device functionality is dependent on the capabilities of a...

  3. Assessment of current and proposed audio alarms in terminal air traffic control.

    DOT National Transportation Integrated Search

    2000-09-01

    The National Airspace System Human Factors Branch (ACT-530) has been engaged in research on the characteristics and use of audio : alerts and alarms in Air Traffic Control. In support of this program, Federal Data Corporation performed a comparative ...

  4. 47 CFR 11.43 - National level participation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false National level participation. 11.43 Section 11.43 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT SYSTEM (EAS... national level EAS may submit a written request to the Chief, Public Safety and Homeland Security Bureau...

  5. CHOOSING THE OPTIMUM FINANCIAL STRATEGY FOR POLLUTION CONTROL INVESTMENTS

    EPA Science Inventory

    This publication was designed to alert industry to qualifications for and availability of financial assistance from federal, state and local governments, and will illustrate that it is well worth the time to analyze the special methods of financing pollution control expenditures ...

  6. Safety of highway-railroad grade crossings : use of auxiliary external alerting devices to improve locomotive conspicuity.

    DOT National Transportation Integrated Search

    1995-07-31

    Historically, highway-railroad grade crossings have represented a major hazard to motor vehicle drivers. The Federal Railroad Administration (FRA), U.S. Department of Transportation (USDOT) has initiated a comprehensive research program to address gr...

  7. Commercial Motor Vehicle, Driver Fatigue And Alertness Study, Technical Summary

    DOT National Transportation Integrated Search

    1999-05-01

    The principal purpose of this study was to provide the Federal Highway Administration with measures to evaluate and assess if the Commercial Driver's License (CDL) program has been effective in (1) addressing problems that led to the enactment of the...

  8. Looking Ahead: The Consequences of a Society with Less Cash/Less Checks

    ERIC Educational Resources Information Center

    MOSAIC, 1976

    1976-01-01

    This technological assessment, conducted by the Arthur D. Little organization, studied the technology of electronic funds transfer. Technology assessment analyzes the economic, social, environmental, and institutional consequences of the introduction or expansion of a technology into society and alerts decision makers to the possible future…

  9. 41 CFR 105-72.503 - Competition.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false Competition. 105-72.503 Section 105-72.503 Public Contracts and Property Management Federal Property Management Regulations System... practical, open and free competition. The recipient shall be alert to organizational conflicts of interest...

  10. Acoustic Data for Hybrid and Electric Heavy-Duty Vehicles and Electric Motorcycles

    DOT National Transportation Integrated Search

    2015-12-01

    The Pedestrian Safety Enhancement Act (PSEA) of 2010 requires NHTSA to conduct a rulemaking to establish a Federal Motor Vehicle Safety Standard requiring an alert sound for pedestrians to be emitted by all types of motor vehicles that are electric o...

  11. 78 FR 53640 - Airworthiness Directives; Airbus Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-30

    ... Airworthiness Directives; Airbus Airplanes AGENCY: Federal Aviation Administration (FAA), Department of... Airbus Model A330-200 Freighter series airplanes; Model A330-200 and - 300 series airplanes, and Model... of the forward or aft cargo door. To address this condition, Airbus issued four separate Alert...

  12. Earthquake alarm; operating the seismograph station at the University of California, Berkeley.

    USGS Publications Warehouse

    Stump, B.

    1980-01-01

    At the University of California seismographic stations, the task of locating and determining magnitudes for both local and distant earthquakes is a continuous one. Teleseisms must be located rapidly so that events that occur in the Pacific can be identified and the Pacific Tsunami Warning System alerted. For great earthquakes anywhere, there is a responsibility to notify public agencies such as the California Office of Emergency Services, the Federal Disaster Assistance Administration, the Earthquake Engineering Research Institute, the California Seismic Safety Commission, and the American Red Cross. In the case of damaging local earthquakes, it is necessary to alert also the California Department of Water Resources, California Division of Mines and Geology, U.S Army Corps of Engineers, Federal Bureau of Reclamation, and the Bay Area Rapid Transit. These days, any earthquakes that are felt in northern California cause immediate inquiries from the news media and an interested public. The series of earthquakes that jolted the Livermore area from January 24 to 26 1980, is a good case in point. 

  13. Combating Terrorism Technology Support Office 2006 Review

    DTIC Science & Technology

    2006-01-01

    emplaced beyond the control point, activated manually or automatically , with warning lights and an audible alarm to alert innocent pedestrians. The...throughout a vehicle. When a tamper event is detected, SERVANT automatically records sensor data and surveillance video and sends an alert to the security...exposure to organophosphate nerve agents, botulinum toxin, cyanide, and carbon monoxide and will be packaged into a portable , lightweight, mobile hand

  14. How Do Science and Technology Affect International Affairs?

    ERIC Educational Resources Information Center

    Weiss, Charles

    2015-01-01

    Science and technology influence international affairs by many different mechanisms. Both create new issues, risks and uncertainties. Advances in science alert the international community to new issues and risks. New technological capabilities transform war, diplomacy, commerce, intelligence, and investment. This paper identifies six basic…

  15. Impact of electronic-alerting of acute kidney injury: workgroup statements from the 15(th) ADQI Consensus Conference.

    PubMed

    Hoste, Eric A J; Kashani, Kianoush; Gibney, Noel; Wilson, F Perry; Ronco, Claudio; Goldstein, Stuart L; Kellum, John A; Bagshaw, Sean M

    2016-01-01

    Among hospitalized patients, acute kidney injury is common and associated with significant morbidity and risk for mortality. The use of electronic health records (EHR) for prediction and detection of this important clinical syndrome has grown in the past decade. The steering committee of the 15(th) Acute Dialysis Quality Initiative (ADQI) conference dedicated a workgroup with the task of identifying elements that may impact the course of events following Acute Kidney Injury (AKI) e-alert. Following an extensive, non-systematic literature search, we used a modified Delphi process to reach consensus regarding several aspects of the utilization of AKI e-alerts. Topics discussed in this workgroup included progress in evidence base practices, the characteristics of an optimal e-alert, the measures of efficacy and effectiveness, and finally what responses would be considered best practices following AKI e-alerts. Authors concluded that the current evidence for e-alert system efficacy, although growing, remains insufficient. Technology and human-related factors were found to be crucial elements of any future investigation or implementation of such tools. The group also concluded that implementation of such systems should not be done without a vigorous plan to evaluate the efficacy and effectiveness of e-alerts. Efficacy and effectiveness of e-alerts should be measured by context-specific process and patient outcomes. Finally, the group made several suggestions regarding the clinical decision support that should be considered following successful e-alert implementation. This paper reflects the findings of a non-systematic review and expert opinion. We recommend implementation of the findings of this workgroup report for use of AKI e-alerts.

  16. Highway work zone intrusion alert systems implementation guide.

    DOT National Transportation Integrated Search

    2017-07-01

    Adopting new technology and innovation is vital for governmental entities to effectively conduct business for its citizens. One major challenge of capturing and realizing the multitude of benefits produced by innovative safety technologies is proper ...

  17. 47 CFR 10.1 - Basis.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Basis. 10.1 Section 10.1 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM General Information § 10.1 Basis... 109-347, Titles I through III of the Communications Act of 1934, as amended, and Executive Order 13407...

  18. 47 CFR 10.350 - WEA Testing requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false WEA Testing requirements. 10.350 Section 10.350 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.350 WEA Testing requirements. This section specifies the testing that will be required, no later than the...

  19. 47 CFR 10.350 - WEA Testing requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false WEA Testing requirements. 10.350 Section 10.350 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.350 WEA Testing requirements. This section specifies the testing that will be required, no later than the...

  20. 47 CFR 10.1 - Basis.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Basis. 10.1 Section 10.1 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM General Information § 10.1 Basis... Response Network Act, Title VI of the Security and Accountability for Every Port Act of 2006, Public Law...

  1. 47 CFR 80.1089 - Ship radio equipment-Sea areas A1 and A2.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... alerts by a radio service other than MF operating either: (i) Through the polar orbiting satellite...; or (iii) Through the INMARSAT geostationary satellite service if within INMARSAT coverage; this....1089 Section 80.1089 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL...

  2. 47 CFR 80.1089 - Ship radio equipment-Sea areas A1 and A2.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... alerts by a radio service other than MF operating either: (i) Through the polar orbiting satellite...; or (iii) Through the INMARSAT geostationary satellite service if within INMARSAT coverage; this....1089 Section 80.1089 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL...

  3. 47 CFR 11.32 - EAS Encoder.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT SYSTEM (EAS) Equipment Requirements § 11... fundamental frequencies of 853 and 960 Hz and not vary over ±0.5 Hz. (ii) Harmonic Distortion. The total... the two tones for calibration of associated systems. (iv) Time Period for Transmission of Tones. The...

  4. 47 CFR 10.1 - Basis.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Network Act, Title VI of the Security and Accountability for Every Port Act of 2006, Public Law 109-347... 47 Telecommunication 1 2013-10-01 2013-10-01 false Basis. 10.1 Section 10.1 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS General Information § 10.1 Basis. The...

  5. 47 CFR 10.1 - Basis.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Network Act, Title VI of the Security and Accountability for Every Port Act of 2006, Public Law 109-347... 47 Telecommunication 1 2014-10-01 2014-10-01 false Basis. 10.1 Section 10.1 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS General Information § 10.1 Basis. The...

  6. The Common Alerting Protocol (CAP) adaption in National Early Warning Alerting Systems of China

    NASA Astrophysics Data System (ADS)

    Li, Chao

    2017-04-01

    The Common Alerting Protocol (CAP) [1] is an XML-based data format for exchanging public warnings and emergencies between alerting technologies. In China, from local communities to entire nations, there was a patchwork of specialized hazard public alerting systems. And each system was often designed just for certain emergency situations and for certain communications media. Application took place in the NEWAS (National Early Warning Alerting Systems) [2]project where CAP serves as central message to integrate all kind of hazard situations, including the natural calamity, accident disaster, public health emergency , social safety etc. Officially operated on May 2015, NEWAS now has completed docking work with 14 departments including civil administration, safety supervision, forestry, land, water conservancy, earthquake, traffic, meteorology, agriculture, tourism, food and drug supervision, public security and oceanic administration. Thus, several items in CAP has been modified, redefined and extended according to the various grading standards and publishing strategies, as well as the characteristics of Chinese Geocoding. NEWAS successfully delivers information to end users through 4 levels (i.e. State, province, prefecture and county) structure and by various means. [1] CAP, http://www.oasis-emergency.org/cap [2] http://www.12379.cn/

  7. The Effect of Automated Alerts on Provider Ordering Behavior in an Outpatient Setting

    PubMed Central

    Steele, Andrew W; Eisert, Sheri; Witter, Joel; Lyons, Pat; Jones, Michael A; Gabow, Patricia; Ortiz, Eduardo

    2005-01-01

    Background Computerized order entry systems have the potential to prevent medication errors and decrease adverse drug events with the use of clinical-decision support systems presenting alerts to providers. Despite the large volume of medications prescribed in the outpatient setting, few studies have assessed the impact of automated alerts on medication errors related to drug–laboratory interactions in an outpatient primary-care setting. Methods and Findings A primary-care clinic in an integrated safety net institution was the setting for the study. In collaboration with commercial information technology vendors, rules were developed to address a set of drug–laboratory interactions. All patients seen in the clinic during the study period were eligible for the intervention. As providers ordered medications on a computer, an alert was displayed if a relevant drug–laboratory interaction existed. Comparisons were made between baseline and postintervention time periods. Provider ordering behavior was monitored focusing on the number of medication orders not completed and the number of rule-associated laboratory test orders initiated after alert display. Adverse drug events were assessed by doing a random sample of chart reviews using the Naranjo scoring scale. The rule processed 16,291 times during the study period on all possible medication orders: 7,017 during the pre-intervention period and 9,274 during the postintervention period. During the postintervention period, an alert was displayed for 11.8% (1,093 out of 9,274) of the times the rule processed, with 5.6% for only “missing laboratory values,” 6.0% for only “abnormal laboratory values,” and 0.2% for both types of alerts. Focusing on 18 high-volume and high-risk medications revealed a significant increase in the percentage of time the provider stopped the ordering process and did not complete the medication order when an alert for an abnormal rule-associated laboratory result was displayed (5.6% vs. 10.9%, p = 0.03, Generalized Estimating Equations test). The provider also increased ordering of the rule-associated laboratory test when an alert was displayed (39% at baseline vs. 51% during post intervention, p < 0.001). There was a non-statistically significant difference towards less “definite” or “probable” adverse drug events defined by Naranjo scoring (10.3% at baseline vs. 4.3% during postintervention, p = 0.23). Conclusion Providers will adhere to alerts and will use this information to improve patient care. Specifically, in response to drug–laboratory interaction alerts, providers will significantly increase the ordering of appropriate laboratory tests. There may be a concomitant change in adverse drug events that would require a larger study to confirm. Implementation of rules technology to prevent medication errors could be an effective tool for reducing medication errors in an outpatient setting. PMID:16128621

  8. A graphical workstation based part-task flight simulator for preliminary rapid evaluation of advanced displays

    NASA Technical Reports Server (NTRS)

    Wanke, Craig; Kuchar, James; Hahn, Edward; Pritchett, Amy; Hansman, R. J.

    1992-01-01

    Advances in avionics and display technology are significantly changing the cockpit environment in current transport aircraft. The MIT Aeronautical Systems Lab (ASL) has developed a part-task flight simulator specifically to study the effects of these new technologies on flight crew situational awareness and performance. The simulator is based on a commercially-available graphics workstation, and can be rapidly reconfigured to meet the varying demands of experimental studies. The simulator has been successfully used to evaluate graphical microburst alerting displays, electronic instrument approach plates, terrain awareness and alerting displays, and ATC routing amendment delivery through digital datalinks.

  9. Nanotechnology Propellant Health Monitoring Sensors; Success Through Multi-Stakeholder Interests

    DTIC Science & Technology

    2014-11-01

    Passive AgeAlert sensors integrate well with passive (no battery!) RFID technology: • RFID reader provides rf energy to read tag providing tag...be added • Reader access to secure server means real time updates Propellant aging sensor Shock sensor Passive RFID tag RFID reader Polymer Aging...Aging Concepts, Inc., Distribution A: Approved for Public Release; Distribution Unlimited Integration of AgeAlert Sensors and Passive RFID 12

  10. Usability Flaws in Medication Alerting Systems: Impact on Usage and Work System.

    PubMed

    Marcilly, R; Ammenwerth, E; Roehrer, E; Pelayo, S; Vasseur, F; Beuscart-Zéphir, M-C

    2015-08-13

    Previous research has shown that medication alerting systems face usability issues. There has been no previous attempt to systematically explore the consequences of usability flaws in such systems on users (i.e. usage problems) and work systems (i.e. negative outcomes). This paper aims at exploring and synthesizing the consequences of usability flaws in terms of usage problems and negative outcomes on the work system. A secondary analysis of 26 papers included in a prior systematic review of the usability flaws in medication alerting was performed. Usage problems and negative outcomes were extracted and sorted. Links between usability flaws, usage problems, and negative outcomes were also analyzed. Poor usability generates a large variety of consequences. It impacts the user from a cognitive, behavioral, emotional, and attitudinal perspective. Ultimately, usability flaws have negative consequences on the workflow, the effectiveness of the technology, the medication management process, and, more importantly, patient safety. Only few complete pathways leading from usability flaws to negative outcomes were identified. Usability flaws in medication alerting systems impede users, and ultimately their work system, and negatively impact patient safety. Therefore, the usability dimension may act as a hidden explanatory variable that could explain, at least partly, the (absence of) intended outcomes of new technology.

  11. Usability Flaws in Medication Alerting Systems: Impact on Usage and Work System

    PubMed Central

    Ammenwerth, E.; Roehrer, E.; Pelayo, S.; Vasseur, F.; Beuscart-Zéphir, M.-C.

    2015-01-01

    Summary Objectives Previous research has shown that medication alerting systems face usability issues. There has been no previous attempt to systematically explore the consequences of usability flaws in such systems on users (i.e. usage problems) and work systems (i.e. negative outcomes). This paper aims at exploring and synthesizing the consequences of usability flaws in terms of usage problems and negative outcomes on the work system. Methods A secondary analysis of 26 papers included in a prior systematic review of the usability flaws in medication alerting was performed. Usage problems and negative outcomes were extracted and sorted. Links between usability flaws, usage problems, and negative outcomes were also analyzed. Results Poor usability generates a large variety of consequences. It impacts the user from a cognitive, behavioral, emotional, and attitudinal perspective. Ultimately, usability flaws have negative consequences on the workflow, the effectiveness of the technology, the medication management process, and, more importantly, patient safety. Only few complete pathways leading from usability flaws to negative outcomes were identified. Conclusion Usability flaws in medication alerting systems impede users, and ultimately their work system, and negatively impact patient safety. Therefore, the usability dimension may act as a hidden explanatory variable that could explain, at least partly, the (absence of) intended outcomes of new technology. PMID:26123906

  12. A New Paradigm of Technology-Enabled ‘Vital Signs’ for Early Detection of Health Change for Older Adults.

    PubMed

    Rantz, Marilyn J; Skubic, Marjorie; Popescu, Mihail; Galambos, Colleen; Koopman, Richelle J; Alexander, Gregory L; Phillips, Lorraine J; Musterman, Katy; Back, Jessica; Miller, Steven J

    2015-01-01

    Environmentally embedded (nonwearable) sensor technology is in continuous use in elder housing to monitor a new set of ‘vital signs' that continuously measure the functional status of older adults, detect potential changes in health or functional status, and alert healthcare providers for early recognition and treatment of those changes. Older adult participants' respiration, pulse, and restlessness are monitored as they sleep. Gait speed, stride length, and stride time are calculated daily, and automatically assess for increasing fall risk. Activity levels are summarized and graphically displayed for easy interpretation. Falls are detected when they occur and alerts are sent immediately to healthcare providers, so time to rescue may be reduced. Automated health alerts are sent to healthcare staff, based on continuously running algorithms applied to the sensor data, days and weeks before typical signs or symptoms are detected by the person, family members, or healthcare providers. Discovering these new functional status ‘vital signs', developing automated methods for interpreting them, and alerting others when changes occur have the potential to transform chronic illness management and facilitate aging in place through the end of life. Key findings of research in progress at the University of Missouri are discussed in this viewpoint article, as well as obstacles to widespread adoption.

  13. 47 CFR 10.340 - Digital television transmission towers retransmission capability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... retransmission capability. 10.340 Section 10.340 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.340 Digital television transmission towers... those terms as defined in section 397(6) of the Communications Act of 1934 (47 U.S.C. 397(6))) are...

  14. 47 CFR 11.31 - EAS protocol.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... End Of Message (EOM) Codes. (1) The Preamble and EAS Codes must use Audio Frequency Shift Keying at a rate of 520.83 bits per second to transmit the codes. Mark frequency is 2083.3 Hz and space frequency... Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT SYSTEM (EAS) Equipment Requirements § 11...

  15. 47 CFR 11.31 - EAS protocol.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... End Of Message (EOM) Codes. (1) The Preamble and EAS Codes must use Audio Frequency Shift Keying at a rate of 520.83 bits per second to transmit the codes. Mark frequency is 2083.3 Hz and space frequency... Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT SYSTEM (EAS) Equipment Requirements § 11...

  16. 47 CFR 11.31 - EAS protocol.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... End Of Message (EOM) Codes. (1) The Preamble and EAS Codes must use Audio Frequency Shift Keying at a rate of 520.83 bits per second to transmit the codes. Mark frequency is 2083.3 Hz and space frequency... Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT SYSTEM (EAS) Equipment Requirements § 11...

  17. 47 CFR 11.31 - EAS protocol.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... End Of Message (EOM) Codes. (1) The Preamble and EAS Codes must use Audio Frequency Shift Keying at a rate of 520.83 bits per second to transmit the codes. Mark frequency is 2083.3 Hz and space frequency... Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT SYSTEM (EAS) Equipment Requirements § 11...

  18. 47 CFR 11.31 - EAS protocol.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... End Of Message (EOM) Codes. (1) The Preamble and EAS Codes must use Audio Frequency Shift Keying at a rate of 520.83 bits per second to transmit the codes. Mark frequency is 2083.3 Hz and space frequency... Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT SYSTEM (EAS) Equipment Requirements § 11...

  19. 47 CFR 11.19 - EAS Non-participating National Authorization Letter.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false EAS Non-participating National Authorization Letter. 11.19 Section 11.19 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT... level EAS. It states that the EAS Participant has agreed to go off the air or discontinue programming on...

  20. 47 CFR 11.19 - EAS Non-participating National Authorization Letter.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false EAS Non-participating National Authorization Letter. 11.19 Section 11.19 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT... level EAS. It states that the EAS Participant has agreed to go off the air or discontinue programming on...

  1. 76 FR 60387 - Privacy Act of 1974: Implementation of Exemptions; Department of Homeland Security Federal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-29

    ...)(3) (Accounting for Disclosures) because release of the accounting of disclosures could alert the... recipient agency. Disclosure of the accounting would therefore present a serious impediment to law enforcement efforts and/or efforts to preserve national security. Disclosure of the accounting would also...

  2. 47 CFR 11.14 - Primary Entry Point (PEP) System.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Primary Entry Point (PEP) System. 11.14 Section 11.14 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT SYSTEM (EAS) General § 11.14 Primary Entry Point (PEP) System. The PEP system is a nationwide network of broadcast...

  3. 47 CFR 11.14 - Primary Entry Point (PEP) System.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Primary Entry Point (PEP) System. 11.14 Section 11.14 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL EMERGENCY ALERT SYSTEM (EAS) General § 11.14 Primary Entry Point (PEP) System. The PEP system is a nationwide network of broadcast...

  4. Integrative Approach for a Transformative Freshman-Level STEM Curriculum

    ERIC Educational Resources Information Center

    D'Souza, Malcolm J.; Curran, Kathleen L.; Olsen, Paul E.; Nwogbaga, Agashi P.; Stotts, Stephanie

    2016-01-01

    In 2014 Wesley College adopted a unified undergraduate program of evidence-based high-impact teaching practices. Through foundation and federal and state grant support, the college completely revised its academic core curriculum and strengthened its academic support structures by including a comprehensive early alert system for at-risk students.…

  5. 47 CFR 10.350 - CMAS Testing requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... later than the date of deployment of the CMAS, of CMAS components. (a) Required monthly tests. Testing... a required monthly test (RMT) message initiated by the Federal Alert Gateway Administrator. (2... maintenance windows. (3) A Participating CMS Provider may forego an RMT if the RMT is pre-empted by actual...

  6. Effect of an active another train coming warning system on pedestrian behavior at a highway-rail grade crossing

    DOT National Transportation Integrated Search

    2014-04-01

    The Federal Railroad Administration (FRA) was interested in evaluating a type of grade crossing safety enhancement which alerts pedestrians at the crossing to the presence of a second train. The system chosen for this analysis, known as an Another Tr...

  7. 47 CFR 80.1089 - Ship radio equipment-Sea areas A1 and A2.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... alerts by a radio service other than MF operating either: (i) Through the polar orbiting satellite... the ship is normally navigated); or (ii) On HF using DSC; or (iii) Through the INMARSAT geostationary....1089 Section 80.1089 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL...

  8. 47 CFR 80.1089 - Ship radio equipment-Sea areas A1 and A2.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... alerts by a radio service other than MF operating either: (i) Through the polar orbiting satellite... the ship is normally navigated); or (ii) On HF using DSC; or (iii) Through the INMARSAT geostationary....1089 Section 80.1089 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL...

  9. 47 CFR 80.1089 - Ship radio equipment-Sea areas A1 and A2.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... alerts by a radio service other than MF operating either: (i) Through the polar orbiting satellite... the ship is normally navigated); or (ii) On HF using DSC; or (iii) Through the INMARSAT geostationary....1089 Section 80.1089 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL...

  10. Counterfeit Version of Botox Found in the United States

    MedlinePlus

    ... fax, or by phone. Health care professionals and consumers can either: Complete and submit the report online: www.fda.gov/MedWatch/report.htm , or ... Continuing Education Inspections & Compliance Federal, State & Local Officials ... Content Home Latest Recalls Report an Adverse Event MedWatch Safety Alerts News Releases ...

  11. 32 CFR 37.570 - What must I do if a CAS-covered participant accounts differently for its own and the Federal...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Accounting Standard (CAS) 402. Noncompliance with CAS 402 is a potential issue only for a participant that... contractors with their ACOs (currently on the World Wide Web at http://alerts.dcmdw.dcma.mil/support, a site...

  12. Global trends in critical values practices and their harmonization.

    PubMed

    Kost, Gerald J; Hale, Kristin N

    2011-02-01

    The objectives of this article were 1) to identify current trends in critical values practices in North America, Europe, and other regions; 2) to describe progress toward harmonization of critical limits; and 3) to synthesize strategies that will encourage global consensus. Critical limits are described in national surveys. Critical value practices are guided by federal statutes, The Joint Commission regulations, and accreditation requirements in the US; by provincial healthcare agencies in Canada; by thought leaders and ISO EN 15189:2007 in Europe; and in SE Asia, mostly by ad hoc policies lacking statutory grip. Review of databases, literature, websites, federal statutes, litigation, official policies, current affairs, and accreditation agency requirements. Practical strategies will accelerate harmonization of critical values practices, as follows: a) continue national and international survey comparisons; b) clarify age, ethnic, and subject dependencies; c) standardize qualitative and quantitative decision levels for urgent clinician notification; d) monitor compliance and timeliness for safety; and e) alert high frequencies of critical values related to adverse events. New expectations and communication technologies present opportunities for enhanced performance using wireless closed-loop reporting with recipient acknowledgment to reduce phone calls and improve efficiency. Hospitals worldwide can benefit from developing consensus for critical values practices.

  13. Technological Proficiency as a Key to Job Security. Trends and Issues Alert No. 6.

    ERIC Educational Resources Information Center

    Imel, Susan

    Although not all current jobs require basic computer skills, technological advances in society have created new jobs and changed the ways many existing jobs are performed. Clearly, workers who are proficient in technology have a greater advantage in the current workplace and the need for technologically proficient workers will only continue to…

  14. Physicians’ use of computerized clinical decision supports to improve medication management in the elderly – the Seniors Medication Alert and Review Technology intervention

    PubMed Central

    Alagiakrishnan, Kannayiram; Wilson, Patricia; Sadowski, Cheryl A; Rolfson, Darryl; Ballermann, Mark; Ausford, Allen; Vermeer, Karla; Mohindra, Kunal; Romney, Jacques; Hayward, Robert S

    2016-01-01

    Background Elderly people (aged 65 years or more) are at increased risk of polypharmacy (five or more medications), inappropriate medication use, and associated increased health care costs. The use of clinical decision support (CDS) within an electronic medical record (EMR) could improve medication safety. Methods Participatory action research methods were applied to preproduction design and development and postproduction optimization of an EMR-embedded CDS implementation of the Beers’ Criteria for medication management and the Cockcroft–Gault formula for estimating glomerular filtration rates (GFR). The “Seniors Medication Alert and Review Technologies” (SMART) intervention was used in primary care and geriatrics specialty clinics. Passive (chart messages) and active (order-entry alerts) prompts exposed potentially inappropriate medications, decreased GFR, and the possible need for medication adjustments. Physician reactions were assessed using surveys, EMR simulations, focus groups, and semi-structured interviews. EMR audit data were used to identify eligible patient encounters, the frequency of CDS events, how alerts were managed, and when evidence links were followed. Results Analysis of subjective data revealed that most clinicians agreed that CDS appeared at appropriate times during patient care. Although managing alerts incurred a modest time burden, most also agreed that workflow was not disrupted. Prevalent concerns related to clinician accountability and potential liability. Approximately 36% of eligible encounters triggered at least one SMART alert, with GFR alert, and most frequent medication warnings were with hypnotics and anticholinergics. Approximately 25% of alerts were overridden and ~15% elicited an evidence check. Conclusion While most SMART alerts validated clinician choices, they were received as valuable reminders for evidence-informed care and education. Data from this study may aid other attempts to implement Beers’ Criteria in ambulatory care EMRs. PMID:26869776

  15. Wireless Emergency Alerts: New York City Demonstration

    DTIC Science & Technology

    2013-06-01

    CMU/SEI-2012-SR-016 | 16  Consider factors affecting continuity of operations, such as support of remote employ- ees, mobile alerting...visitors and tourists , we’ll be even safer when authorities can broadcast warnings to everyone in a geographic area regardless of where they came from or...using technology to help keep people safe. [Office of the Mayor 2011b] Mayor Bloomberg declared his intention to make this new service available to New

  16. 77 FR 13483 - Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-07

    ... Directives; Rolls-Royce plc (RR) Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION... service information identified in this AD, contact Rolls-Royce plc, Corporate Communications, P.O. Box 31...), or, have Rolls-Royce plc revise Alert Service Bulletin (ASB) No. RB.211-72-AF964 to remove the...

  17. 10 CFR Appendix E to Part 50 - Emergency Planning and Preparedness for Production and Utilization Facilities

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... organization shall be described. The communication steps to be taken to alert or activate emergency personnel... operations facility must include the following: (1) Space for members of an NRC site team and Federal, State, and local responders; (2) Additional space for conducting briefings with emergency response personnel...

  18. 10 CFR Appendix E to Part 50 - Emergency Planning and Preparedness for Production and Utilization Facilities

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... organization shall be described. The communication steps to be taken to alert or activate emergency personnel... operations facility must include the following: (1) Space for members of an NRC site team and Federal, State, and local responders; (2) Additional space for conducting briefings with emergency response personnel...

  19. 10 CFR Appendix E to Part 50 - Emergency Planning and Preparedness for Production and Utilization Facilities

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... organization shall be described. The communication steps to be taken to alert or activate emergency personnel... operations facility must include the following: (1) Space for members of an NRC site team and Federal, State, and local responders; (2) Additional space for conducting briefings with emergency response personnel...

  20. 78 FR 41342 - Approval and Promulgation of Air Quality Implementation Plans; State of Colorado Second Ten-Year...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-10

    ... instructions for submitting comments. Email: ostigaard.crystal@epa.gov . Fax: (303) 312-6064 (please alert the.... FOR FURTHER INFORMATION CONTACT: Crystal Ostigaard, Air Program, U.S. Environmental Protection Agency....crystal@epa.gov . SUPPLEMENTARY INFORMATION: In the Rules section of this Federal Register, EPA is...

  1. 78 FR 57573 - Approval and Promulgation of Air Quality Implementation Plans; State of Colorado Second Ten-Year...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-19

    ... submitting comments. Email: ostigaard.crystal@epa.gov . Fax: (303) 312-6064 (please alert the individual.... FOR FURTHER INFORMATION CONTACT: Crystal Ostigaard, Air Program, U.S. Environmental Protection Agency....crystal@epa.gov . SUPPLEMENTARY INFORMATION: In the Rules section of this Federal Register, EPA is...

  2. 14 CFR 91.219 - Altitude alerting system or device: Turbojet-powered civil airplanes.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...: Turbojet-powered civil airplanes. 91.219 Section 91.219 Aeronautics and Space FEDERAL AVIATION... system or device: Turbojet-powered civil airplanes. (a) Except as provided in paragraph (d) of this section, no person may operate a turbojet-powered U.S.-registered civil airplane unless that airplane is...

  3. 14 CFR 91.219 - Altitude alerting system or device: Turbojet-powered civil airplanes.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...: Turbojet-powered civil airplanes. 91.219 Section 91.219 Aeronautics and Space FEDERAL AVIATION... system or device: Turbojet-powered civil airplanes. (a) Except as provided in paragraph (d) of this section, no person may operate a turbojet-powered U.S.-registered civil airplane unless that airplane is...

  4. 14 CFR 91.219 - Altitude alerting system or device: Turbojet-powered civil airplanes.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...: Turbojet-powered civil airplanes. 91.219 Section 91.219 Aeronautics and Space FEDERAL AVIATION... system or device: Turbojet-powered civil airplanes. (a) Except as provided in paragraph (d) of this section, no person may operate a turbojet-powered U.S.-registered civil airplane unless that airplane is...

  5. 14 CFR 91.219 - Altitude alerting system or device: Turbojet-powered civil airplanes.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...: Turbojet-powered civil airplanes. 91.219 Section 91.219 Aeronautics and Space FEDERAL AVIATION... system or device: Turbojet-powered civil airplanes. (a) Except as provided in paragraph (d) of this section, no person may operate a turbojet-powered U.S.-registered civil airplane unless that airplane is...

  6. 76 FR 70638 - Privacy Act of 1974: Implementation of Exemptions; Department of Homeland Security/U.S...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-15

    ... Disclosures) because release of the accounting of disclosures could alert the subject of an investigation of... efforts to preserve national security. Disclosure of the accounting would also permit the individual who... of Federal Regulations, as follows: PART 5--DISCLOSURE OF RECORDS AND INFORMATION 0 1. The authority...

  7. 76 FR 42004 - Privacy Act of 1974: Implementation of Exemptions; Department of Homeland Security Federal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-18

    ... compromise the objectivity or fairness of the testing or examination process.'' Exemptions from these..., for the following reasons: (a) From subsection (c)(3) (Accounting for Disclosures) because release of the accounting of disclosures could alert the subject of an investigation of an actual or potential...

  8. 14 CFR 91.219 - Altitude alerting system or device: Turbojet-powered civil airplanes.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...: Turbojet-powered civil airplanes. 91.219 Section 91.219 Aeronautics and Space FEDERAL AVIATION... system or device: Turbojet-powered civil airplanes. (a) Except as provided in paragraph (d) of this section, no person may operate a turbojet-powered U.S.-registered civil airplane unless that airplane is...

  9. 77 FR 33995 - Petition Filed by American Cable Association for Partial Reconsideration of the Commission's...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-08

    ... Fifth Report and Order; Announces Schedule for Pleading Cycle AGENCY: Federal Communications Commission... Alert System (EAS) Fifth Report and Order, and announces a schedule for the pleading cycle. DATES... process last at least one year. By the Public Notice, the Commission establishes a pleading cycle for...

  10. How to Get JDRP Approval of Career Education Activities.

    ERIC Educational Resources Information Center

    Hamilton, Jack A.

    The purpose of this monograph is to aid practitioners in gaining federal Joint Dissemination Review Panel (JDRP) approval of career education projects. It helps them understand the importance of designing and implementing a sound evaluation from the early stages of the program, alerts them to common errors or omissions that weaken or destroy…

  11. 16 CFR Appendix A to Part 681 - Interagency Guidelines on Identity Theft Detection, Prevention, and Mitigation

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation A Appendix A to Part 681 Commercial Practices FEDERAL TRADE COMMISSION...

  12. 16 CFR Appendix A to Part 681 - Interagency Guidelines on Identity Theft Detection, Prevention, and Mitigation

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation A Appendix A to Part 681 Commercial Practices FEDERAL TRADE COMMISSION...

  13. 16 CFR Appendix A to Part 681 - Interagency Guidelines on Identity Theft Detection, Prevention, and Mitigation

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation A Appendix A to Part 681 Commercial Practices FEDERAL TRADE COMMISSION...

  14. 16 CFR Appendix A to Part 681 - Interagency Guidelines on Identity Theft Detection, Prevention, and Mitigation

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation A Appendix A to Part 681 Commercial Practices FEDERAL TRADE COMMISSION...

  15. School on Alert over Water Quality

    ERIC Educational Resources Information Center

    Bowman, Darcia Harris

    2004-01-01

    This article examines the issue on the quality of water in Seattle's school districts. Seattle's water woes became public when four little containers of rust-colored water from fountains in the city district's Wedgewood Elementary School, collected by concerned parents, were tested by a certified laboratory and found to exceed federal lead limits.…

  16. 77 FR 69558 - Airworthiness Directives; Eurocopter Deutschland GmbH Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-20

    ... Airworthiness Directives; Eurocopter Deutschland GmbH Helicopters AGENCY: Federal Aviation Administration (FAA... airworthiness directive (AD) for Eurocopter Deutschland GmbH (ECD) Model EC135 P1, EC135 P2, EC135 P2+, EC135 T1... with this AD through an AMOC. (h) Additional Information (1) Eurocopter Emergency Alert Service...

  17. Sounding the Alert: Designing an Effective Voice for Earthquake Early Warning

    NASA Astrophysics Data System (ADS)

    Burkett, E. R.; Given, D. D.

    2015-12-01

    The USGS is working with partners to develop the ShakeAlert Earthquake Early Warning (EEW) system (http://pubs.usgs.gov/fs/2014/3083/) to protect life and property along the U.S. West Coast, where the highest national seismic hazard is concentrated. EEW sends an alert that shaking from an earthquake is on its way (in seconds to tens of seconds) to allow recipients or automated systems to take appropriate actions at their location to protect themselves and/or sensitive equipment. ShakeAlert is transitioning toward a production prototype phase in which test users might begin testing applications of the technology. While a subset of uses will be automated (e.g., opening fire house doors), other applications will alert individuals by radio or cellphone notifications and require behavioral decisions to protect themselves (e.g., "Drop, Cover, Hold On"). The project needs to select and move forward with a consistent alert sound to be widely and quickly recognized as an earthquake alert. In this study we combine EEW science and capabilities with an understanding of human behavior from the social and psychological sciences to provide insight toward the design of effective sounds to help best motivate proper action by alert recipients. We present a review of existing research and literature, compiled as considerations and recommendations for alert sound characteristics optimized for EEW. We do not yet address wording of an audible message about the earthquake (e.g., intensity and timing until arrival of shaking or possible actions), although it will be a future component to accompany the sound. We consider pitch(es), loudness, rhythm, tempo, duration, and harmony. Important behavioral responses to sound to take into account include that people respond to discordant sounds with anxiety, can be calmed by harmony and softness, and are innately alerted by loud and abrupt sounds, although levels high enough to be auditory stressors can negatively impact human judgment.

  18. Sense and avoid technology for unmanned aircraft systems

    NASA Astrophysics Data System (ADS)

    McCalmont, John; Utt, James; Deschenes, Michael; Taylor, Michael; Sanderson, Richard; Montgomery, Joel; Johnson, Randal S.; McDermott, David

    2007-04-01

    The Sensors Directorate of the Air Force Research Laboratory (AFRL), in conjunction with the Global Hawk Systems Group, the J-UCAS System Program Office and contractor Defense Research Associates, Inc. (DRA) is conducting an Advanced Technology Demonstration (ATD) of a sense-and-avoid capability with the potential to satisfy the Federal Aviation Administration's (FAA) requirement for Unmanned Aircraft Systems (UAS) to provide "an equivalent level of safety, comparable to see-and-avoid requirements for manned aircraft". This FAA requirement must be satisfied for UAS operations within the national airspace. The Sense-and-Avoid, Phase I (Man-in-the-Loop) and Phase II (Autonomous Maneuver) ATD demonstrated an on-board, wide field of regard, multi-sensor visible imaging system operating in real time and capable of passively detecting approaching aircraft, declaring potential collision threats in a timely manner and alerting the human pilot located in the remote ground control station or autonomously maneuvered the aircraft. Intruder declaration data was collected during the SAA I & II Advanced Technology Demonstration flights conducted during December 2006. A total of 27 collision scenario flights were conducted and analyzed. The average detection range was 6.3 NM and the mean declaration range was 4.3 NM. The number of false alarms per engagement has been reduced to approximately 3 per engagement.

  19. 2005 Science and Technology for Chem-Bio Information Systems (S and T CBIS). Volume 2 - Wednesday

    DTIC Science & Technology

    2005-10-28

    historical example of using both an audible and visual alerting method. In April 1775, Revere hung two lanterns in the bell-tower of Christ Church in...individual building systems, outdoor systems, telephone notification systems and a network of alert sensors . Fire protection systems are often... sensor , be it a pushbutton at a gate, a wireless “panic” button or a CBRNE detector, may be programmed to trigger notifications without further

  20. Point Positioning Service for Natural Hazard Monitoring

    NASA Astrophysics Data System (ADS)

    Bar-Sever, Y. E.

    2014-12-01

    In an effort to improve natural hazard monitoring, JPL has invested in updating and enlarging its global real-time GNSS tracking network, and has launched a unique service - real-time precise positioning for natural hazard monitoring, entitled GREAT Alert (GNSS Real-Time Earthquake and Tsunami Alert). GREAT Alert leverages the full technological and operational capability of the JPL's Global Differential GPS System [www.gdgps.net] to offer owners of real-time dual-frequency GNSS receivers: Sub-5 cm (3D RMS) real-time, absolute positioning in ITRF08, regardless of location Under 5 seconds turnaround time Full covariance information Estimates of ancillary parameters (such as troposphere) optionally provided This service enables GNSS networks operators to instantly have access to the most accurate and reliable real-time positioning solutions for their sites, and also to the hundreds of participating sites globally, assuring inter-consistency and uniformity across all solutions. Local authorities with limited technical and financial resources can now access to the best technology, and share environmental data to the benefit of the entire pacific region. We will describe the specialized precise point positioning techniques employed by the GREAT Alert service optimized for natural hazard monitoring, and in particular Earthquake monitoring. We address three fundamental aspects of these applications: 1) small and infrequent motion, 2) the availability of data at a central location, and 3) the need for refined solutions at several time scales

  1. Impact of real-time electronic alerting of acute kidney injury on therapeutic intervention and progression of RIFLE class.

    PubMed

    Colpaert, Kirsten; Hoste, Eric A; Steurbaut, Kristof; Benoit, Dominique; Van Hoecke, Sofie; De Turck, Filip; Decruyenaere, Johan

    2012-04-01

    To evaluate whether a real-time electronic alert system or "AKI sniffer," which is based on the RIFLE classification criteria (Risk, Injury and Failure), would have an impact on therapeutic interventions and acute kidney injury progression. Prospective intervention study. Surgical and medical intensive care unit in a tertiary care hospital. A total of 951 patients having in total 1,079 admission episodes were admitted during the study period (prealert control group: 227, alert group: 616, and postalert control group: 236). Three study phases were compared: A 1.5-month prealert control phase in which physicians were blinded for the acute kidney injury sniffer and a 3-month intervention phase with real-time alerting of worsening RIFLE class through the Digital Enhanced Cordless Technology telephone system followed by a second 1.5-month postalert control phase. A total of 2593 acute kidney injury alerts were recorded with a balanced distribution over all study phases. Most acute kidney injury alerts were RIFLE class risk (59.8%) followed by RIFLE class injury (34.1%) and failure (6.1%). A higher percentage of patients in the alert group received therapeutic intervention within 60 mins after the acute kidney injury alert (28.7% in alert group vs. 7.9% and 10.4% in the pre- and postalert control groups, respectively, p μ .001). In the alert group, more patients received fluid therapy (23.0% vs. 4.9% and 9.2%, p μ .01), diuretics (4.2% vs. 2.6% and 0.8%, p μ .001), or vasopressors (3.9% vs. 1.1% and 0.8%, p μ .001). Furthermore, these patients had a shorter time to intervention (p μ .001). A higher proportion of patients in the alert group showed return to a baseline kidney function within 8 hrs after an acute kidney injury alert "from normal to risk" compared with patients in the control group (p = .048). The real-time alerting of every worsening RIFLE class by the acute kidney injury sniffer increased the number and timeliness of early therapeutic interventions. The borderline significant improvement of short-term renal outcome in the RIFLE class risk patients needs to be confirmed in a large multicenter trial.

  2. Crew Alertness Management on the Flight Deck: Cognitive and Vigilance Performance

    NASA Technical Reports Server (NTRS)

    Dinges, David F.

    1998-01-01

    This project had three broad goals: (1) to identify environmental and organismic risks to performance of long-haul cockpit crews; (2) to assess how cognitive and psychomotor vigilance performance, and subjective measures of alertness, were affected by work-rest schedules typical of long-haul cockpit crews; and (3) to determine the alertness-promoting effectiveness of behavioral and technological countermeasures to fatigue on the flight deck. During the course of the research, a number of studies were completed in cooperation with the NASA Ames Fatigue Countermeasures Program. The publications emerging from this project are listed in a bibliography in the appendix. Progress toward these goals will be summarized below according to the period in which it was accomplished.

  3. Which components of health information technology will drive financial value?

    PubMed

    Kern, Lisa M; Wilcox, Adam; Shapiro, Jason; Dhopeshwarkar, Rina V; Kaushal, Rainu

    2012-08-01

    The financial effects of electronic health records (EHRs) and health information exchange (HIE) are largely unknown, despite unprecedented federal incentives for their use. We sought to understand which components of EHRs and HIE are most likely to drive financial savings in the ambulatory, inpatient, and emergency department settings. Framework development and a national expert panel. We searched the literature to identify functionalities enabled by EHRs and HIE across the 3 healthcare settings. We rated each of 233 functionality-setting combinations on their likelihood of having a positive financial effect. We validated the top-scoring functionalities with a panel of 28 national experts, and we compared the high-scoring functionalities with Stage 1 meaningful use criteria. We identified 54 high-scoring functionality- setting combinations, 27 for EHRs and 27 for HIE. Examples of high-scoring functionalities included providing alerts for expensive medications, providing alerts for redundant lab orders, sending and receiving imaging reports, and enabling structured medication reconciliation. Of the 54 high-scoring functionalities, 25 (46%) are represented in Stage 1 meaningful use. Many of the functionalities not yet represented in meaningful use correspond with functionalities that focus directly on healthcare utilization and costs rather than on healthcare quality per se. This work can inform the development and selection of future meaningful use measures; inform implementation efforts, as clinicians and hospitals choose from among a "menu" of measures for meaningful use; and inform evaluation efforts, as investigators seek to measure the actual financial impact of EHRs and HIE.

  4. Future Earth: Reducing Loss By Automating Response to Earthquake Shaking

    NASA Astrophysics Data System (ADS)

    Allen, R. M.

    2014-12-01

    Earthquakes pose a significant threat to society in the U.S. and around the world. The risk is easily forgotten given the infrequent recurrence of major damaging events, yet the likelihood of a major earthquake in California in the next 30 years is greater than 99%. As our societal infrastructure becomes ever more interconnected, the potential impacts of these future events are difficult to predict. Yet, the same inter-connected infrastructure also allows us to rapidly detect earthquakes as they begin, and provide seconds, tens or seconds, or a few minutes warning. A demonstration earthquake early warning system is now operating in California and is being expanded to the west coast (www.ShakeAlert.org). In recent earthquakes in the Los Angeles region, alerts were generated that could have provided warning to the vast majority of Los Angelinos who experienced the shaking. Efforts are underway to build a public system. Smartphone technology will be used not only to issue that alerts, but could also be used to collect data, and improve the warnings. The MyShake project at UC Berkeley is currently testing an app that attempts to turn millions of smartphones into earthquake-detectors. As our development of the technology continues, we can anticipate ever-more automated response to earthquake alerts. Already, the BART system in the San Francisco Bay Area automatically stops trains based on the alerts. In the future, elevators will stop, machinery will pause, hazardous materials will be isolated, and self-driving cars will pull-over to the side of the road. In this presentation we will review the current status of the earthquake early warning system in the US. We will illustrate how smartphones can contribute to the system. Finally, we will review applications of the information to reduce future losses.

  5. Over-reliance on technology is bad news for care.

    PubMed

    Davies, Julia

    2010-09-22

    I teach pre-registration nursing students clinical skills. Here in Shropshire, hospitals use an automated data collection system designed to alert nurses when the patient's condition is deteriorating. The dominance of such technology sometimes makes me think about hanging up my uniform for good.

  6. US and Dutch nurse experiences with fall prevention technology within nursing home environment and workflow: A qualitative study.

    PubMed

    Vandenberg, Ann E; van Beijnum, Bert-Jan; Overdevest, Vera G P; Capezuti, Elizabeth; Johnson, Theodore M

    Falls remain a major geriatric problem, and the search for new solutions continues. We investigated how existing fall prevention technology was experienced within nursing home nurses' environment and workflow. Our NIH-funded study in an American nursing home was followed by a cultural learning exchange with a Dutch nursing home. We constructed two case reports from interview and observational data and compared the magnitude of falls, safety cultures, and technology characteristics and effectiveness. Falls were a high-magnitude problem at the US site, with a collectively vigilant safety culture attending to non-directional audible alarms; falls were a low-magnitude problem at the NL site which employed customizable, infrared sensors that directed text alerts to assigned staff members' mobile devices in patient-centered care culture. Across cases, 1) a coordinated communication system was essential in facilitating effective fall prevention alert response, and 2) nursing home safety culture is tightly associated with the chosen technological system. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Impact of Technology on Human Rights: Responsibilities and Opportunities for the Social Studies.

    ERIC Educational Resources Information Center

    Higbee, Jay A.

    The author purports the need to control technology for the well-being of mankind by understanding and cultivating its beneficial features and countering its harmful effects and misuse. The intent of the paper is to alert social studies teachers to the responsibility of bridging the gap between scientific and technological knowledge and civic and…

  8. Automatic feedback to promote safe walking and speech loudness control in persons with multiple disabilities: two single-case studies.

    PubMed

    Lancioni, Giulio E; Singh, Nirbhay N; O'Reilly, Mark F; Green, Vanessa A; Alberti, Gloria; Boccasini, Adele; Smaldone, Angela; Oliva, Doretta; Bosco, Andrea

    2014-08-01

    Assessing automatic feedback technologies to promote safe travel and speech loudness control in two men with multiple disabilities, respectively. The men were involved in two single-case studies. In Study I, the technology involved a microprocessor, two photocells, and a verbal feedback device. The man received verbal alerting/feedback when the photocells spotted an obstacle in front of him. In Study II, the technology involved a sound-detecting unit connected to a throat and an airborne microphone, and to a vibration device. Vibration occurred when the man's speech loudness exceeded a preset level. The man included in Study I succeeded in using the automatic feedback in substitution of caregivers' alerting/feedback for safe travel. The man of Study II used the automatic feedback to successfully reduce his speech loudness. Automatic feedback can be highly effective in helping persons with multiple disabilities improve their travel and speech performance.

  9. Safety & Health. Resource Guide for Occupational/Technology Education.

    ERIC Educational Resources Information Center

    Kirk, Albert S., Ed.

    This guide is intended to alert occupational/technology teachers, teacher educators, school administrators, and industrial education supervisors to the need and importance of a strong and active safety program. Responsibilities are detailed for all individuals involved. Teacher liability is addressed. A section on emergency procedures covers…

  10. Afterschool Programs: Keeping Kids -- and Communities -- Safe. Afterschool Alert. Issue Brief No. 27

    ERIC Educational Resources Information Center

    Afterschool Alliance, 2007

    2007-01-01

    After 14 years of decline, cities across the nation are reporting spikes in crime rates, which many law enforcement officials attribute to decreased federal spending on crime prevention and more juveniles becoming involved in violent crimes. This report highlights the "after-school" gap: 20-25 hours per week that children are out of…

  11. New Federal Rule Can Help You Fight Asbestos in Your Children's School.

    ERIC Educational Resources Information Center

    Gibbs, Lois; And Others

    1982-01-01

    This article alerts parents to the danger of asbestos exposure in schools and urges parent teacher associations to demand corrective action. It explains: (1) how to identify asbestos; (2) how to remove it; and (3) how to recover costs from the industry. A recently enacted rule by the Environmental Protection Agency is stated. (PP)

  12. 77 FR 1387 - Privacy Act of 1974: Implementation of Exemptions; Department of Homeland Security/Federal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-10

    ... request is made, for the following reasons: (a) From subsection (c)(3) (Accounting for Disclosures) because release of the accounting of disclosures could alert the subject of an investigation of an actual... national security. Disclosure of the accounting would also permit the individual who is the subject of a...

  13. 78 FR 59090 - Nissan North America, Incorporated, Grant of Petition for Decision of Inconsequential Noncompliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-25

    ... alert a driver exiting the vehicle if the key remained in the starting system. Furthermore, if the..., buses or multipurpose passenger vehicles (MPVs) manufactured from December 20, 2010 to July 17, 2012, do not fully comply with paragraph S3.1.4.1 of Federal Motor Vehicle Safety Standard (FMVSS) No. 102...

  14. 12 CFR Appendix J to Part 222 - Interagency Guidelines on Identity Theft Detection, Prevention, and Mitigation

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation J Appendix J to Part 222 Banks and Banking FEDERAL RESERVE SYSTEM...

  15. 12 CFR Appendix J to Part 334 - Interagency Guidelines on Identity Theft Detection, Prevention, and Mitigation

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... should take steps to ensure that the activity of the service provider is conducted in accordance with... financial institution or creditor detects a fraud or active duty alert; (c) Implementing any requirements... Detection, Prevention, and Mitigation J Appendix J to Part 334 Banks and Banking FEDERAL DEPOSIT INSURANCE...

  16. 12 CFR Appendix to Subpart C of... - Interagency Guidelines on Identity Theft Detection, Prevention, and Mitigation

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the financial institution or creditor should take steps to ensure that the activity of the service... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation Appendix to Subpart C of Part 391 Banks and Banking FEDERAL DEPOSIT...

  17. 12 CFR Appendix J to Part 222 - Interagency Guidelines on Identity Theft Detection, Prevention, and Mitigation

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation J Appendix J to Part 222 Banks and Banking FEDERAL RESERVE SYSTEM...

  18. 12 CFR Appendix J to Part 334 - Interagency Guidelines on Identity Theft Detection, Prevention, and Mitigation

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... should take steps to ensure that the activity of the service provider is conducted in accordance with... financial institution or creditor detects a fraud or active duty alert; (c) Implementing any requirements... Detection, Prevention, and Mitigation J Appendix J to Part 334 Banks and Banking FEDERAL DEPOSIT INSURANCE...

  19. 12 CFR Appendix to Subpart C of... - Interagency Guidelines on Identity Theft Detection, Prevention, and Mitigation

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the financial institution or creditor should take steps to ensure that the activity of the service... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation Appendix to Subpart C of Part 391 Banks and Banking FEDERAL DEPOSIT...

  20. 12 CFR Appendix J to Part 222 - Interagency Guidelines on Identity Theft Detection, Prevention, and Mitigation

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation J Appendix J to Part 222 Banks and Banking FEDERAL RESERVE SYSTEM...

  1. 12 CFR Appendix J to Part 222 - Interagency Guidelines on Identity Theft Detection, Prevention, and Mitigation

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... covered accounts the financial institution or creditor should take steps to ensure that the activity of... detects a fraud or active duty alert; (c) Implementing any requirements for furnishers of information to... Detection, Prevention, and Mitigation J Appendix J to Part 222 Banks and Banking FEDERAL RESERVE SYSTEM...

  2. 12 CFR Appendix J to Part 334 - Interagency Guidelines on Identity Theft Detection, Prevention, and Mitigation

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... should take steps to ensure that the activity of the service provider is conducted in accordance with... financial institution or creditor detects a fraud or active duty alert; (c) Implementing any requirements... Detection, Prevention, and Mitigation J Appendix J to Part 334 Banks and Banking FEDERAL DEPOSIT INSURANCE...

  3. Ultrawideband Electromagnetic Interference to Aircraft Radios: Results of Limited Functional Testing With United Airlines and Eagles Wings Incorporated, in Victorville, California

    NASA Technical Reports Server (NTRS)

    Ely, Jay J.; Shaver, Timothy W.; Fuller, Gerald L.

    2002-01-01

    On February 14, 2002, the FCC adopted a FIRST REPORT AND ORDER, released it on April 22, 2002, and on May 16, 2002 published in the Federal Register a Final Rule, permitting marketing and operation of new products incorporating UWB technology. Wireless product developers are working to rapidly bring this versatile, powerful and expectedly inexpensive technology into numerous consumer wireless devices. Past studies addressing the potential for passenger-carried portable electronic devices (PEDs) to interfere with aircraft electronic systems suggest that UWB transmitters may pose a significant threat to aircraft communication and navigation radio receivers. NASA, United Airlines and Eagles Wings Incorporated have performed preliminary testing that clearly shows the potential for handheld UWB transmitters to cause cockpit failure indications for the air traffic control radio beacon system (ATCRBS), blanking of aircraft on the traffic alert and collision avoidance system (TCAS) displays, and cause erratic motion and failure of instrument landing system (ILS) localizer and glideslope pointers on the pilot horizontal situation and attitude director displays. This report provides details of the preliminary testing and recommends further assessment of aircraft systems for susceptibility to UWB electromagnetic interference.

  4. Incidence of potential drug interactions in a transplant centre setting and relevance of electronic alerts for clinical practice support.

    PubMed

    Polidori, Piera; Di Giorgio, Concetta; Provenzani, Alessio

    2012-01-01

    Adverse drug events may occur as a result of drug-drug interactions (DDIs). Information technology (IT) systems can be an important decision-making tool for healthcare workers to identify DDIs. The aim of the study is to analyse drug prescriptions in our main hospital units, in order to measure the incidence and severity of potential DDIs. The utility of clinical decision-support systems (CDSSs) and computerised physician order entry (CPOE) in term of alerts adherence was also assessed. DDIs were assessed using a Micromedex® healthcare series database. The system, adopted by the hospital, generates alerts for prescriptions with negative interactions and thanks to an 'acknowledgement function' it is possible to verify physician adherence to alerts. This function, although used previously, became mandatory from September 2010. Physician adherence to alerts and mean monthly incidence of potential DDIs in analysed units, before and after the mandatory 'acknowledgement function', were calculated. The intensive care unit (ICU) registered the greatest incidence of potential DDIs (49.0%), followed by the abdominal surgery unit and dialysis (43.4 and 42.0%, respectively). The cardiothoracic surgery unit (41.6%), step-down unit (38.3%) and post-anaesthesia care unit (30.0%) were comparable. The operating theatre and endoscopy registered the fewest potential DDIs (28.2 and 22.7%, respectively). Adherence to alerts after the 'acknowledgement function' increased by 25.0% in the ICU, 54.0% in the cardiothoracic surgery unit, 52.5% in the abdominal surgery unit, 58.0% in the stepdown unit, 67.0% in dialysis, 51.0% in endoscopy and 48.0% in the post-anaesthesia care unit. In the operating theatre, adherence to alerts decreased from 34.0 to 30.0%. The incidence of potential DDIs after mandatory use of the 'acknowledgement function' decreased slightly in endoscopy (-2.9%), the abdominal surgery unit (-2.7%), dialysis (-1.9%) and the step-down unit (-1.4%). Improving DDI alerts will improved patient safety by more appropriately alerting clinicians.

  5. Presenting Critical Space Weather Information to Customers and Stakeholders (Invited)

    NASA Astrophysics Data System (ADS)

    Viereck, R. A.; Singer, H. J.; Murtagh, W. J.; Rutledge, B.

    2013-12-01

    Space weather involves changes in the near-Earth space environment that impact technological systems such as electric power, radio communication, satellite navigation (GPS), and satellite opeartions. As with terrestrial weather, there are several different kinds of space weather and each presents unique challenges to the impacted technologies and industries. But unlike terrestrial weather, many customers are not fully aware of space weather or how it impacts their systems. This issue is further complicated by the fact that the largest space weather events occur very infrequently with years going by without severe storms. Recent reports have estimated very large potential costs to the economy and to society if a geomagnetic storm were to cause major damage to the electric power transmission system. This issue has come to the attention of emergency managers and federal agencies including the office of the president. However, when considering space weather impacts, it is essential to also consider uncertainties in the frequency of events and the predicted impacts. The unique nature of space weather storms, the specialized technologies that are impacted by them, and the disparate groups and agencies that respond to space weather forecasts and alerts create many challenges to the task of communicating space weather information to the public. Many customers that receive forecasts and alerts are highly technical and knowledgeable about the subtleties of the space environment. Others know very little and require ongoing education and explanation about how a space weather storm will affect their systems. In addition, the current knowledge and understanding of the space environment that goes into forecasting storms is quite immature. It has only been within the last five years that physics-based models of the space environment have played important roles in predictions. Thus, the uncertainties in the forecasts are quite large. There is much that we don't know about space weather and this influences our forecasts. In this presentation, I will discuss the unique challenges that space weather forecasters face when explaining what we know and what we don't know about space weather events to customers and policy makers.

  6. The Electronic Portfolio: Ethical Considerations

    ERIC Educational Resources Information Center

    McFadden, Joan R.; Saiki, Diana

    2005-01-01

    Computer technology has become important in Family and Consumer Science (FCS) because it offers improved communication with capabilities such as the Internet that allows for a "more productive workplace" (Jones, 2003, p. 38). Kittross and Gordon (2003) alerted users that as computer technology evolves, there is a need for colleges and universities…

  7. Electronic Current Awareness in the Corporate Environment.

    ERIC Educational Resources Information Center

    Sale, Elizabeth

    Technological developments such as groupware and World Wide Web technology have opened up new opportunities for the delivery of information directly to the end-user's desktop. These advances have meant that suppliers are now producing a new breed of current awareness services (CAS), termed alerting services, which automatically filter newswires…

  8. The EDUTECH Report, 2001-2002.

    ERIC Educational Resources Information Center

    Warger, Thomas, Ed.

    2002-01-01

    This document consists of 12 issues of the "EDUTECH Report." The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two feature articles, a page of news briefs, and a question and answer column. Issues also contain brief quotations on education technology topics. The…

  9. Important imaging finding e-mail alert system: experience after 3 years of implementation.

    PubMed

    Abujudeh, Hani H; Kaewlai, Rathachai; Choy, Garry; Whelton, Dianne G; Rosenthal, Daniel I

    2009-09-01

    To evaluate the effectiveness of an important finding alert (IFA) system that uses e-mail technology to alert referring physicians to an important but nonurgent imaging finding. The institutional review board approved the study; the requirement for informed consent was waived. The authors retrospectively reviewed the radiology reports generated from January 2005 to December 2007 to determine how many reports contained an IFA statement, how many IFA messages were sent, and how many such messages were viewed by referring physicians. They reviewed 1000 randomly selected radiology reports that contained the IFA statement to identify the imaging modalities and findings that triggered the radiologists' use of the IFA system. A total of 1540254 radiology reports were generated during the 3-year period. A total of 56 691 (3.7%) reports contained the IFA statement. IFA e-mail messages were sent for 52 883 (93.3%) of the 56 691 reports, and 42 285 (74.6%) of the 56 691 reports were viewed by the referring physicians. The most common important but nonurgent findings were definitive (449 [44.9%] of 1000 reports) and indeterminate (260 [26.0%] of 1000 reports) abnormalities. More than half (n = 503) of the alerts were related to computed tomographic examinations, and the majority (n = 677, 67.7%) of them were initiated by thoracic and abdominal radiologists. The IFA system is a potentially useful method of communicating nonurgent but important imaging findings with use of e-mail technology.

  10. Fatigue in Younger and Older Drivers: Effectiveness of an Alertness-Maintaining Task.

    PubMed

    Song, Woojin; Woon, Fu L; Doong, Alice; Persad, Carol; Tijerina, Louis; Pandit, Pooja; Cline, Carol; Giordani, Bruno

    2017-09-01

    The aim of this study was to examine the effects of an alertness-maintaining task (AMT) in older, fatigued drivers. Fatigue during driving increases crash risk, and previous research suggests that alertness and driving in younger adults may be improved using a secondary AMT during boring, fatigue-eliciting drives. However, the potential impact of an AMT on driving has not been investigated in older drivers whose ability to complete dual tasks has been shown to decline and therefore may be negatively affected with an AMT in driving. Younger ( n = 29) and older drivers ( n = 39) participated in a 50-minute simulated drive designed to induce fatigue, followed by four 10-minute sessions alternating between driving with and without an AMT. Younger drivers were significantly more affected by fatigue on driving performance than were older drivers but benefitted significantly from the AMT. Older drivers did not demonstrate increased driver errors with fatigue, and driving did not deteriorate significantly during participation in the AMT condition, although their speed was significantly more variable with the AMT. Consistent with earlier research, an AMT applied during fatiguing driving is effective in improving alertness and reducing driving errors in younger drivers. Importantly, older drivers were relatively unaffected by fatigue, and use of an AMT did not detrimentally affect their driving performance. These results support the potential use of an AMT as a new automotive technology to improve fatigue and promote driver safety, though the benefits of such technology may differ between different age groups.

  11. A trial of retrofitted advisory collision avoidance technology in government fleet vehicles.

    PubMed

    Thompson, James P; Mackenzie, Jamie R R; Dutschke, Jeffrey K; Baldock, Matthew R J; Raftery, Simon J; Wall, John

    2018-06-01

    In-vehicle collision avoidance technology (CAT) has the potential to prevent crash involvement. In 2015, Transport for New South Wales undertook a trial of a Mobileye 560 CAT system that was installed in 34 government fleet vehicles for a period of seven months. The system provided headway monitoring, lane departure, forward collision and pedestrian collision warnings, using audio and visual alerts. The purpose of the trial was to determine whether the technology could change the driving behaviour of fleet vehicle drivers and improve their safety. The evaluation consisted of three components: (1) analysis of objective data to examine effects of the technology on driving behaviour, (2) analysis of video footage taken from a sample of the vehicles to examine driving circumstances that trigger headway monitoring and forward collision warnings, and (3) a survey completed by 122 of the 199 individuals who drove the trial vehicles to examine experiences with, and attitudes to, the technology. Analysis of the objective data found that the system resulted in changes in behaviour with increased headway and improved lane keeping, but that these improvements dissipated once the warning alerts were switched off. Therefore, the system is capable of altering behaviour but only when it is actively providing alerts. In-vehicle video footage revealed that over a quarter of forward collision warnings were false alarms, in which a warning event was triggered despite there being no vehicle travelling ahead. The surveyed drivers recognised that the system could improve safety but most did not wish to use it themselves as they found it to be distracting and felt that it would not prevent them from having a crash. The results demonstrate that collision avoidance technology can improve driving behaviour but drivers may need to be educated about the potential benefits for their driving in order to accept the technology. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Design of anti-theft/cable cut real time alert system for copper cable using microcontroller and GSM technology

    NASA Astrophysics Data System (ADS)

    Lim, E. K.; Norizan, M. N.; Mohamad, I. S.; Yasin, M. N. M.; Murad, S. A. Z.; Baharum, N. A.; Jamalullail, N.

    2017-09-01

    This paper presents the design of anti-theft/cable cut real time alert system using microcontroller and GSM technology. The detection part is using the electrical circuit wire connection in detecting the voltage drop of the cable inside the microcontroller digital input port. The GSM wireless modem is used to send the location of cable cut directly to the authority mobile phone. Microcontroller SK40C with Microchip PIC16F887 is used as a controller to control the wireless modem and also the detection device. The device is able to detect and display the location of the cable cut on the LCD display besides of and sending out the location of the cable break to the authority mobile phone wirelessly via SMS.

  13. 49 CFR Appendix A to Part 209 - Statement of Agency Policy Concerning Enforcement of the Federal Railroad Safety Laws

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... exercise of jurisdiction. In this context, the presence of intrusion detection devices to alert one or both... about sufficient intrusion detection and related safety measures designed to avoid a collision between...). By “general railroad system of transportation,” FRA refers to the network of standard gage track over...

  14. 49 CFR Appendix A to Part 209 - Statement of Agency Policy Concerning Enforcement of the Federal Railroad Safety Laws

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... exercise of jurisdiction. In this context, the presence of intrusion detection devices to alert one or both... about sufficient intrusion detection and related safety measures designed to avoid a collision between...). By “general railroad system of transportation,” FRA refers to the network of standard gage track over...

  15. 49 CFR Appendix A to Part 209 - Statement of Agency Policy Concerning Enforcement of the Federal Railroad Safety Laws

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... exercise of jurisdiction. In this context, the presence of intrusion detection devices to alert one or both... about sufficient intrusion detection and related safety measures designed to avoid a collision between...). By “general railroad system of transportation,” FRA refers to the network of standard gage track over...

  16. A Quantitative Experimental Study of the Effectiveness of Systems to Identify Network Attackers

    ERIC Educational Resources Information Center

    Handorf, C. Russell

    2016-01-01

    This study analyzed the meta-data collected from a honeypot that was run by the Federal Bureau of Investigation for a period of 5 years. This analysis compared the use of existing industry methods and tools, such as Intrusion Detection System alerts, network traffic flow and system log traffic, within the Open Source Security Information Manager…

  17. 75 FR 38394 - Airworthiness Directives; The Boeing Company Model 747-100, -200B, and -200F Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-02

    ... Airworthiness Directives; The Boeing Company Model 747-100, - 200B, and -200F Series Airplanes AGENCY: Federal... inconsistent with the terminology used in the structural repair manual and Boeing Alert Service Bulletin 747... The Boeing Company Model 747-100, 747- 200B, and 747-200F series airplanes, certificated in any...

  18. 76 FR 76068 - Airworthiness Directives; Eurocopter Deutschland GmbH Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-06

    ... Deutschland GmbH Helicopters AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed... GmbH Model BO-105A, BO-105C, BO-105LS A-1, BO- 105LS A-3, and BO-105S helicopters. This proposed AD... airworthy main rotor blade. Note 1: Eurocopter Deutschland GmbH Emergency Alert Service Bulletin No. BO105...

  19. Alerting, orienting or executive attention networks: differential patters of pupil dilations

    PubMed Central

    Geva, Ronny; Zivan, Michal; Warsha, Aviv; Olchik, Dov

    2013-01-01

    Attention capacities, alerting responses, orienting to sensory stimulation, and executive monitoring of performance are considered independent yet interrelated systems. These operations play integral roles in regulating the behavior of diverse species along the evolutionary ladder. Each of the primary attention constructs—alerting, orienting, and executive monitoring—involves salient autonomic correlates as evidenced by changes in reactive pupil dilation (PD), heart rate, and skin conductance. Recent technological advances that use remote high-resolution recording may allow the discernment of temporo-spatial attributes of autonomic responses that characterize the alerting, orienting, and executive monitoring networks during free viewing, irrespective of voluntary performance. This may deepen the understanding of the roles of autonomic regulation in these mental operations and may deepen our understanding of behavioral changes in verbal as well as in non-verbal species. The aim of this study was to explore differences between psychosensory PD responses in alerting, orienting, and executive conflict monitoring tasks to generate estimates of concurrent locus coeruleus (LC) noradrenergic input trajectories in healthy human adults using the attention networks test (ANT). The analysis revealed a construct-specific pattern of pupil responses: alerting is characterized by an early component (Pa), its acceleration enables covert orienting, and executive control is evidenced by a prominent late component (Pe). PD characteristics seem to be task-sensitive, allowing exploration of mental operations irrespective of conscious voluntary responses. These data may facilitate development of studies designed to assess mental operations in diverse species using autonomic responses. PMID:24133422

  20. A Hole in the Weather Warning System.

    NASA Astrophysics Data System (ADS)

    Wood, Vincent T.; Weisman, Robert A.

    2003-02-01

    lack of text information. These problems had forced deaf and hard of hearing people to rely on looking at the sky or having hearing people alert them as their primary methods of receiving emergency information. These problems are documented through the use of a survey of 277 deaf and hard of hearing people in Minnesota and Oklahoma as well as specific examples.During the last two years, some progress has been made to "close this hole" in the weather warning system. The Federal Communications Commission has approved new rules, requiring that all audio emergency information provided by television stations, satellite, and cable operators must also be provided visually. In addition, the use of new technology such as pager systems, weather radios adapted for use by those with special needs, the Internet, and satellite warning systems have allowed deaf and hard of hearing people to have more access to emergency information.In this article, these improvements are documented but continuing problems and possible solutions are also listed.

  1. Surveillance data management system

    NASA Astrophysics Data System (ADS)

    Teague, Ralph

    2002-10-01

    On October 8, 2001, an Executive Order was signed creating the White House Office of Homeland Security. With its formaiton comes focused attention in setting goals and priorities for homeland security. Analysis, preparation, and implementation of strategies will hinge not only on how information is collected and analyzed, but more important, on how it is coordinated and shared. Military installations/facilities, Public safety agencies, airports, federal and local offices, public utilities, harbors, transportation and others critical areas must work either independently or as a team to ensure the safety of our citizens and visitor. In this new era of increased security, the key to interoperation is continuous information exchanged-events must be rapidly identified, reported and responded to by the appropriate agencies. For instance when a threat has been detected the security officers must be immediately alerted and must have access to the type of threat, location, movement, heading, threat size, etc to respond accordingly and the type of support required. This requires instant communications and teamwork with reliable and flexible technology.

  2. Adaptive notification framework for smart nursing home.

    PubMed

    Betge-Brezetz, S; Dupont, M P; Ghorbel, M; Kamga, G B; Piekarec, S

    2009-01-01

    This paper presents an adaptive notification framework which allows to optimally deliver and handle multimedia requests and alerts in a nursing home. This framework is operated with various applications (e.g., health alert, medicine reminder, and activity proposition) and has been evaluated with different real end-users (elderly resident and medical staff) in a pilot site. Results of these evaluations are presented and highlight the added value of the framework technology to enhance the quality of life of elderly people as well as the efficiency of the medical staff.

  3. Translating the Science of Alertness and Performance from Laboratory to Field: Using State-of-the-Art Monitoring Imaging and Performance Enhancement Technologies to Improve the Alertness and Safety of the Military and Civilian Workforce

    DTIC Science & Technology

    2008-06-01

    imaging (fMRI) environments, b) custom 32 channel electrode caps for use in fMRI environmentsnew EEG/ EOG signal analysts software, c) ambulatory...personnel 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: REPORT b. ABSTRACT u c. THIS PAGE U 17. LIMITATION OF ABSTRACT SAR 18. NUMBER...digital electroencephalogram (EEG) and electrooculogram ( EOG ) recording systems for ambulatory use as well as for use in functional magnet-resonance

  4. E-print Network home page -- Energy, science, and technology for the

    Science.gov Websites

    Home * About * Advanced Search * Browse by Discipline * Scientific Societies * E-print Alerts * Add E -prints Energy, science, and technology for the research community! Enter Search Terms Search Advanced at advanced levels. . . . a gateway to over 35,300 websites and databases worldwide, containing over

  5. New Technologies and Emerging Careers. Trends and Issues Alerts.

    ERIC Educational Resources Information Center

    Kerka, Sandra

    Technological innovations are giving rise to structural changes in the economy that are in turn creating profound changes in the nature of work and work organizations. Predicted changes are: traditional hierarchical organizations in the workplace will give way to network or weblike forms of organization; customary vertical divisions of labor will…

  6. Florida manatee avoidance technology: A pilot program by the Florida Fish and Wildlife Conservation Commission

    NASA Astrophysics Data System (ADS)

    Frisch, Katherine; Haubold, Elsa

    2003-10-01

    Since 1976, approximately 25% of the annual Florida manatee (Trichechus manatus latirostris) mortality has been attributed to collisions with watercraft. In 2001, the Florida Legislature appropriated $200,000 in funds for research projects using technological solutions to directly address the problem of collisions between manatees and watercraft. The Florida Fish & Wildlife Conservation Commission initially funded seven projects for the first two fiscal years. The selected proposals were designed to explore technology that had not previously been applied to the manatee/boat collision problem and included many acoustic concepts related to voice recognition, sonar, and an alerting device to be put on boats to warn manatees. The most promising results to date are from projects employing voice-recognition techniques to identify manatee vocalizations and warn boaters of the manatees' presence. Sonar technology, much like that used in fish finders, is promising but has met with regulatory problems regarding permitting and remains to be tested, as has the manatee-alerting device. The state of Florida found results of the initial years of funding compelling and plans to fund further manatee avoidance technology research in a continued effort to mitigate the problem of manatee/boat collisions.

  7. Humanizing Aggregated Data: Developing Personas to Prioritize User Needs for Earthquake Early Warning

    NASA Astrophysics Data System (ADS)

    Burkett, E. R.; Jayanty, N. K.; Sellnow, D. D.; Given, D. D.; DeGroot, R. M.

    2016-12-01

    Methods that use storytelling to gather and synthesize data from people can be advantageous in understanding user needs and designing successful communication products. Using a multidisciplinary approach, we research and prioritize user needs for the ShakeAlert Earthquake Early Warning system (http://pubs.usgs.gov/fs/2014/3083/), drawing on best practices from social and behavioral science, risk communication, and human-centered design. We apply quantitative and qualitative human data collection methods including user surveys, interviews, journey maps, personas, and scenarios. Human-centered design methods leverage storytelling (a) in the acquisition of qualitative behavioral data (e.g. with journey mapping), (b) through goal-driven behaviors and needs that are synthesized into a persona as a composite model of the data, and (c) within context scenarios (the story plot or projected circumstances) in which the persona is placed in context to inform the design of relevant and usable products or services. ShakeAlert, operated by the USGS and partners, has transitioned into a production prototype phase in which users are permitted to begin testing pilot implementations to take protective actions in response to an earthquake alert. While a subset of responses will be automated (e.g., opening fire house doors), other applications of the technology will alert individuals by broadcast, public address, or mobile device notifications and require self-protective behavioral decisions (e.g., "Drop, Cover, and Hold On"). To better understand ShakeAlert user decisions and needs, we use human-centered design methods to synthesize aggregated behavioral data into "personas," which model the common behavioral patterns that can be used to guide plans for the ShakeAlert interface, messaging, and training. We present user data, methods, and resulting personas that will inform decisions moving forward to shape ShakeAlert messaging and training that will be most usable by alert recipients.

  8. Biofeedback: It's Time to Try Hardware in the Classroom

    ERIC Educational Resources Information Center

    Mulholland, Thomas B.

    1973-01-01

    A pioneer in the field tries to close the communications gap between biofeedback and education by showing how the technology can help students stay alert, feel better and explore inner space. (Editor)

  9. 75 FR 27964 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-22B and RB211-524 Series Turbofan Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-19

    ...-1157; Directorate Identifier 2009-NE-26-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... p.m., Monday through Friday, except Federal holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc... Information Rolls-Royce plc has issued Alert Service Bulletin RB.211-72-AF336, dated October 24, 2007. The...

  10. 75 FR 61363 - Airworthiness Directives; Rolls-Royce plc RB211-524 Series, -535 Series, RB211 Trent 700 Series...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-05

    ...-0993; Directorate Identifier 2010-NE-08-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc... Federal holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United... examining the MCAI in the AD docket. Relevant Service Information Rolls-Royce plc has issued Alert Service...

  11. 75 FR 48615 - Airworthiness Directives; Eurocopter France (ECF) Model AS350B3 and EC130 B4 Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-11

    .... Related Service Information ECF has issued Alert Service Bulletin (ASB) No. 05.00.61 for the Model AS350B3... Airworthiness Directives; Eurocopter France (ECF) Model AS350B3 and EC130 B4 Helicopters AGENCY: Federal... adopt a new airworthiness directive (AD) for the specified ECF model helicopters. This proposed AD...

  12. 76 FR 76293 - Airworthiness Directives; BRP-Powertrain GmbH & Co. KG Reciprocating Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-07

    ... Airworthiness Directives; BRP-Powertrain GmbH & Co. KG Reciprocating Engines AGENCY: Federal Aviation... directive (AD) for BRP- Powertrain GmbH & Co. KG Rotax 912 F2, 912 F3, 912 F4, 912 S2, 912 S3, 912 S4, 914...-Powertrain GmbH & Co. KG, Rotax Aircraft Engines, Mandatory Alert Service Bulletins (ASB) Nos. ASB-912-059...

  13. Development and validation of a survey instrument for assessing prescribers' perception of computerized drug-drug interaction alerts.

    PubMed

    Zheng, Kai; Fear, Kathleen; Chaffee, Bruce W; Zimmerman, Christopher R; Karls, Edward M; Gatwood, Justin D; Stevenson, James G; Pearlman, Mark D

    2011-12-01

    To develop a theoretically informed and empirically validated survey instrument for assessing prescribers' perception of computerized drug-drug interaction (DDI) alerts. The survey is grounded in the unified theory of acceptance and use of technology and an adapted accident causation model. Development of the instrument was also informed by a review of the extant literature on prescribers' attitude toward computerized medication safety alerts and common prescriber-provided reasons for overriding. To refine and validate the survey, we conducted a two-stage empirical validation study consisting of a pretest with a panel of domain experts followed by a field test among all eligible prescribers at our institution. The resulting survey instrument contains 28 questionnaire items assessing six theoretical dimensions: performance expectancy, effort expectancy, social influence, facilitating conditions, perceived fatigue, and perceived use behavior. Satisfactory results were obtained from the field validation; however, a few potential issues were also identified. We analyzed these issues accordingly and the results led to the final survey instrument as well as usage recommendations. High override rates of computerized medication safety alerts have been a prevalent problem. They are usually caused by, or manifested in, issues of poor end user acceptance. However, standardized research tools for assessing and understanding end users' perception are currently lacking, which inhibits knowledge accumulation and consequently forgoes improvement opportunities. The survey instrument presented in this paper may help fill this methodological gap. We developed and empirically validated a survey instrument that may be useful for future research on DDI alerts and other types of computerized medication safety alerts more generally.

  14. Hazards in Motion: Development of Mobile Geofences for Use in Logging Safety

    PubMed Central

    Zimbelman, Eloise G.; Keefe, Robert F.; Strand, Eva K.; Kolden, Crystal A.; Wempe, Ann M.

    2017-01-01

    Logging is one of the most hazardous occupations in the United States. Real-time positioning that uses global navigation satellite system (GNSS) technology paired with radio frequency transmission (GNSS-RF) has the potential to reduce fatal and non-fatal accidents on logging operations through the use of geofences that define safe work areas. Until recently, most geofences have been static boundaries. The aim of this study was to evaluate factors affecting mobile geofence accuracy in order to determine whether virtual safety zones around moving ground workers or equipment are a viable option for improving situational awareness on active timber sales. We evaluated the effects of walking pace, transmission interval, geofence radius, and intersection angle on geofence alert delay using a replicated field experiment. Simulation was then used to validate field results and calculate the proportion of GNSS error bearings resulting in early alerts. The interaction of geofence radius and intersection angle affected safety geofence alert delay in the field experiment. The most inaccurate alerts were negative, representing early warning. The magnitude of this effect was largest at the greatest intersection angles. Simulation analysis supported these field results and also showed that larger GNSS error corresponded to greater variability in alert delay. Increasing intersection angle resulted in a larger proportion of directional GNSS error that triggered incorrect, early warnings. Because the accuracy of geofence alerts varied greatly depending on GNSS error and angle of approach, geofencing for occupational safety is most appropriate for general situational awareness unless real-time correction methods to improve accuracy or higher quality GNSS-RF transponders are used. PMID:28394303

  15. Centralized Alert-Processing and Asset Planning for Sensorwebs

    NASA Technical Reports Server (NTRS)

    Castano, Rebecca; Chien, Steve A.; Rabideau, Gregg R.; Tang, Benyang

    2010-01-01

    A software program provides a Sensorweb architecture for alert-processing, event detection, asset allocation and planning, and visualization. It automatically tasks and re-tasks various types of assets such as satellites and robotic vehicles in response to alerts (fire, weather) extracted from various data sources, including low-level Webcam data. JPL has adapted cons iderable Sensorweb infrastructure that had been previously applied to NASA Earth Science applications. This NASA Earth Science Sensorweb has been in operational use since 2003, and has proven reliability of the Sensorweb technologies for robust event detection and autonomous response using space and ground assets. Unique features of the software include flexibility to a range of detection and tasking methods including those that require aggregation of data over spatial and temporal ranges, generality of the response structure to represent and implement a range of response campaigns, and the ability to respond rapidly.

  16. Unmanned Aircraft Systems Minimum Operations Performance Standards End-to-End Verification and Validation (E2-V2) Simulation

    NASA Technical Reports Server (NTRS)

    Ghatas, Rania W.; Jack, Devin P.; Tsakpinis, Dimitrios; Vincent, Michael J.; Sturdy, James L.; Munoz, Cesar A.; Hoffler, Keith D.; Dutle, Aaron M.; Myer, Robert R.; Dehaven, Anna M.; hide

    2017-01-01

    As Unmanned Aircraft Systems (UAS) make their way to mainstream aviation operations within the National Airspace System (NAS), research efforts are underway to develop a safe and effective environment for their integration into the NAS. Detect and Avoid (DAA) systems are required to account for the lack of "eyes in the sky" due to having no human on-board the aircraft. The current NAS relies on pilot's vigilance and judgement to remain Well Clear (CFR 14 91.113) of other aircraft. RTCA SC-228 has defined DAA Well Clear (DAAWC) to provide a quantified Well Clear volume to allow systems to be designed and measured against. Extended research efforts have been conducted to understand and quantify system requirements needed to support a UAS pilot's ability to remain well clear of other aircraft. The efforts have included developing and testing sensor, algorithm, alerting, and display requirements. More recently, sensor uncertainty and uncertainty mitigation strategies have been evaluated. This paper discusses results and lessons learned from an End-to-End Verification and Validation (E2-V2) simulation study of a DAA system representative of RTCA SC-228's proposed Phase I DAA Minimum Operational Performance Standards (MOPS). NASA Langley Research Center (LaRC) was called upon to develop a system that evaluates a specific set of encounters, in a variety of geometries, with end-to-end DAA functionality including the use of sensor and tracker models, a sensor uncertainty mitigation model, DAA algorithmic guidance in both vertical and horizontal maneuvering, and a pilot model which maneuvers the ownship aircraft to remain well clear from intruder aircraft, having received collective input from the previous modules of the system. LaRC developed a functioning batch simulation and added a sensor/tracker model from the Federal Aviation Administration (FAA) William J. Hughes Technical Center, an in-house developed sensor uncertainty mitigation strategy, and implemented a pilot model similar to one from the Massachusetts Institute of Technology's Lincoln Laboratory (MIT/LL). The resulting simulation provides the following key parameters, among others, to evaluate the effectiveness of the MOPS DAA system: severity of loss of well clear (SLoWC), alert scoring, and number of increasing alerts (alert jitter). The technique, results, and lessons learned from a detailed examination of DAA system performance over specific test vectors and encounter cases during the simulation experiment will be presented in this paper.

  17. Alerting or Somnogenic Light: Pick Your Color.

    PubMed

    Bourgin, Patrice; Hubbard, Jeffrey

    2016-08-01

    In mammals, light exerts pervasive effects on physiology and behavior in two ways: indirectly through clock synchronization and the phase adjustment of circadian rhythms, and directly through the promotion of alertness and sleep, respectively, in diurnal and nocturnal species. A recent report by Pilorz and colleagues describes an even more complex role for the acute effects of light. In mice, blue light acutely causes behavioral arousal, whereas green wavelengths promote sleep. These opposing effects are mediated by melanopsin-based phototransduction through different neural pathways. These findings reconcile nocturnal and diurnal species through a common alerting response to blue light. One can hypothesize that the opposite responses to natural polychromatic light in night- or day-active animals may reflect higher sensitivity of nocturnal species to green, and diurnals to blue wavelengths, resulting in hypnogenic and alerting effects, respectively. Additional questions remain to be clarified. How do different light wavelengths affect other behaviors such as mood and cognition? How do those results apply to humans? How does light pose either a risk or benefit, depending on whether one needs to be asleep or alert? Indeed, in addition to timing, luminance levels, and light exposure duration, these findings stress the need to understand how best to adapt the color spectrum of light to our needs and to take this into account for the design of daily lighting concepts-a key challenge for today's society, especially with the emergence of LED light technology.

  18. Experiences of model year 2011 Dodge and Jeep owners with collision avoidance and related technologies.

    PubMed

    Cicchino, Jessica B; McCartt, Anne T

    2015-01-01

    Crash avoidance technologies have the potential to prevent or mitigate many crashes, but their effectiveness depends on drivers' acceptance and proper use. Owners of 2011 Dodge Charger, Dodge Durango, and Jeep Grand Cherokee vehicles were interviewed about their experiences with their vehicles' technologies. Interviews were conducted in April 2013 with 215 owners of Dodge and Jeep vehicles with adaptive cruise control and forward collision warning and 215 owners with blind spot monitoring and rear cross-path detection. Most owners said that they always keep each collision avoidance technology turned on, and more than 90% of owners with each system would want the technology again on their next vehicle. The majority believed that the systems had helped prevent a collision; this ranged from 54% of drivers with forward collision warning to more than three-quarters with blind spot monitoring and rear cross-path detection. Some owners reported behavioral changes with the systems, but over-reliance on them is not prevalent. Reported use of the systems varied by the age and gender of the driver and duration of vehicle ownership to a greater degree than in previous surveys of luxury Volvo and Infiniti vehicles with collision avoidance technologies. Notably, drivers aged 40 and younger were most likely to report that forward collision warning had alerted them multiple times and that it had prevented a collision and that they follow the vehicle ahead less closely with adaptive cruise control. Reports of waiting for the alert from forward collision warning before braking were infrequent but increased with duration of ownership. However, these reports could reflect confusion of the system with adaptive cruise control, which alerts drivers when braking is necessary to maintain a preset speed or following distance but a crash is not imminent. Consistent with previous surveys of luxury vehicle owners with collision avoidance technologies, acceptance and use remains high among owners of more mainstream vehicles. Varying experiences with the technologies by driver age and gender suggest that safety benefits are not uniform for all drivers, and differential benefits may become increasingly apparent as collision avoidance technologies become available to a more heterogeneous population of drivers. The potential for over-reliance on the technologies should continue to be monitored, especially as drivers gain more experience with them.

  19. DANTi: Detect and Avoid iN The Cockpit

    NASA Technical Reports Server (NTRS)

    Chamberlain, James; Consiglio, Maria; Munoz, Cesar

    2017-01-01

    Mid-air collision risk continues to be a concern for manned aircraft operations, especially near busy non-towered airports. The use of Detect and Avoid (DAA) technologies and draft standards developed for unmanned aircraft systems (UAS), either alone or in combination with other collision avoidance technologies, may be useful in mitigating this collision risk for manned aircraft. This paper describes a NASA research effort known as DANTi (DAA iN The Cockpit), including the initial development of the concept of use, a software prototype, and results from initial flight tests conducted with this prototype. The prototype used a single Automatic Dependent Surveillance - Broadcast (ADS-B) traffic sensor and the own aircraft's position, track, heading and air data information, along with NASA-developed DAA software to display traffic alerts and maneuver guidance to manned aircraft pilots on a portable tablet device. Initial flight tests with the prototype showed a successful DANTi proof-of-concept, but also demonstrated that the traffic separation parameter set specified in the RTCA SC-228 Phase I DAA MOPS may generate excessive false alerts during traffic pattern operations. Several parameter sets with smaller separation values were also tested in flight, one of which yielded more timely alerts for the maneuvers tested. Results from this study may further inform future DANTi efforts as well as Phase II DAA MOPS development.

  20. An investigation of air transportation technology at the Massachusetts Institute of Technology, 1992-1993

    NASA Technical Reports Server (NTRS)

    Simpson, Robert W.

    1994-01-01

    An investigation of air transportation technology at MIT during 1992 - 1993 is presented. One completed project and two continuing research activities are under the sponsorship of the FAA/NASA Joint University Program. The completed project was on tracking aircraft around a turn with wind effects. Active research projects are on ASLOTS - an interactive adaptive system of automated approach spacing of aircraft and alerting in automated and datalink capable cockpits.

  1. Site Remediation Technology InfoBase: A Guide to Federal Programs, Information Resources, and Publications on Contaminated Site Cleanup Technologies. First Edition

    NASA Technical Reports Server (NTRS)

    1998-01-01

    Table of Contents: Federal Cleanup Programs; Federal Site Remediation Technology Development Assistance Programs; Federal Site Remediation Technology Development Electronic Data Bases; Federal Electronic Resources for Site Remediation Technology Information; Other Electronic Resources for Site Remediation Technology Information; Other Electronic Resources for Site Remediation Technology Information; Selected Bibliography: Federal Publication on Alternative and Innovative Site Remediation; and Appendix: Technology Program Contacts.

  2. 31 CFR 901.4 - Reporting debts.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and Urban Development's Credit Alert Interactive Voice Response System (CAIVRS). For information about the CAIVRS program, agencies should contact the Director of Information Resources Management Policy and Management Division, Office of Information Technology, Department of Housing and Urban Development...

  3. 31 CFR 901.4 - Reporting debts.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and Urban Development's Credit Alert Interactive Voice Response System (CAIVRS). For information about the CAIVRS program, agencies should contact the Director of Information Resources Management Policy and Management Division, Office of Information Technology, Department of Housing and Urban Development...

  4. National Institutes of Health Clinical Alerts and Advisories

    MedlinePlus

    ... Health & Toxicology Health Services Research & Public Health Health Information Technology NLM for You Grants & Funding Meaningful Use Tools Training & Outreach Network of Medical Libraries Regional ... Important Therapeutic Information on the Benefit of Zidovudine (AZT) for the ...

  5. Health information technology to guide pediatric obesity management.

    PubMed

    McDonald, Julia; Goldman, Roberta E; O'Brien, Ashley; Ayash, Christine; Mitchell, Kathy; Marshall, Richard; Simon, Steven R; Taveras, Elsie M

    2011-06-01

    The purpose of this study was to examine pediatricians' familiarity with expert committee recommendations on the management of childhood obesity and their use of health information technology for obesity-related care. The authors interviewed 35 pediatricians from 17 primary care practices using an electronic health record; immersion crystallization facilitated analysis of the qualitative data. Nearly all pediatricians were unfamiliar with expert recommendations; however, all participants reported using growth charts and providing nutrition and physical activity counseling. Most participants wanted easy access to educational materials they could print for patients. The majority of participants were in favor of an electronic alert to identify obese patients, remind clinicians of current guidelines, and facilitate ordering, believing it would help standardize care. Concerns included "alert fatigue," distraction, and disruption of workflow. Suggestions for future electronic functions included tailored educational materials and physical activity resources customized by patient address.

  6. U.S. preparedness for severe storms questioned

    NASA Astrophysics Data System (ADS)

    Showstack, Randy

    Doug Hill, chief meteorologist for WJLA-TV in Washington, D.C., recalled the broadcast news coverage of two supercell thunderstorms that swept through the region on September 24, producing three tornadoes and causing two fatalities. Hill said that only one local radio station which airs his forecasts activated the federal emergency alert system to immediately notify the public about the tornadoes, and added that there should be some changes in requirements. “Somehow, broadcast stations have to get the idea that these warnings and requests to activate [the alerts] are not done [just] for fun,” he said.Hill was among several experts appearing at an October 11 congressional hearing, “Weatherproofing the U.S.: Are We Prepared for Severe Storms?” The hearing, which was held by the U.S. House of Representatives' Science Committee, included testimony about the nation's emergency preparedness in dealing with several types of severe weather: tornadoes, hurricanes, and wind storms.

  7. REFINE (Reducing Falls in In-patient Elderly)--a randomised controlled trial.

    PubMed

    Vass, Catherine D; Sahota, Opinder; Drummond, Avril; Kendrick, Denise; Gladman, John; Sach, Tracey; Avis, Mark; Grainge, Matthew

    2009-09-10

    Falls in hospitals are common, resulting in injury and anxiety to patients, and large costs to NHS organisations. More than half of all in-patient falls in elderly people in acute care settings occur at the bedside, during transfers or whilst getting up to go to the toilet. In the majority of cases these falls are unwitnessed. There is insufficient evidence underpinning the effectiveness of interventions to guide clinical staff regarding the reduction of falls in the elderly inpatient. New patient monitoring technologies have the potential to offer advances in falls prevention. Bedside sensor equipment can alert staff, not in the immediate vicinity, to a potential problem and avert a fall. However no studies utilizing this assistive technology have demonstrated a significant reduction in falls rates in a randomised controlled trial setting. The research design is an individual patient randomised controlled trial of bedside chair and bed pressure sensors, incorporating a radio-paging alerting mode to alert staff to patients rising from their bed or chair, across five acute elderly care wards in Nottingham University Hospitals NHS Trust. Participants will be randomised to bedside chair and bed sensors or to usual care (without the use of sensors). The primary outcome is the number of bedside in-patient falls. The REFINE study is the first randomised controlled trial of bedside pressure sensors in elderly inpatients in an acute NHS Trust. We will assess whether falls can be successfully and cost effectively reduced using this technology, and report on its acceptability to both patients and staff.

  8. Evening use of light-emitting eReaders negatively affects sleep, circadian timing, and next-morning alertness

    PubMed Central

    Chang, Anne-Marie; Aeschbach, Daniel; Duffy, Jeanne F.; Czeisler, Charles A.

    2015-01-01

    In the past 50 y, there has been a decline in average sleep duration and quality, with adverse consequences on general health. A representative survey of 1,508 American adults recently revealed that 90% of Americans used some type of electronics at least a few nights per week within 1 h before bedtime. Mounting evidence from countries around the world shows the negative impact of such technology use on sleep. This negative impact on sleep may be due to the short-wavelength–enriched light emitted by these electronic devices, given that artificial-light exposure has been shown experimentally to produce alerting effects, suppress melatonin, and phase-shift the biological clock. A few reports have shown that these devices suppress melatonin levels, but little is known about the effects on circadian phase or the following sleep episode, exposing a substantial gap in our knowledge of how this increasingly popular technology affects sleep. Here we compare the biological effects of reading an electronic book on a light-emitting device (LE-eBook) with reading a printed book in the hours before bedtime. Participants reading an LE-eBook took longer to fall asleep and had reduced evening sleepiness, reduced melatonin secretion, later timing of their circadian clock, and reduced next-morning alertness than when reading a printed book. These results demonstrate that evening exposure to an LE-eBook phase-delays the circadian clock, acutely suppresses melatonin, and has important implications for understanding the impact of such technologies on sleep, performance, health, and safety. PMID:25535358

  9. Evening use of light-emitting eReaders negatively affects sleep, circadian timing, and next-morning alertness.

    PubMed

    Chang, Anne-Marie; Aeschbach, Daniel; Duffy, Jeanne F; Czeisler, Charles A

    2015-01-27

    In the past 50 y, there has been a decline in average sleep duration and quality, with adverse consequences on general health. A representative survey of 1,508 American adults recently revealed that 90% of Americans used some type of electronics at least a few nights per week within 1 h before bedtime. Mounting evidence from countries around the world shows the negative impact of such technology use on sleep. This negative impact on sleep may be due to the short-wavelength-enriched light emitted by these electronic devices, given that artificial-light exposure has been shown experimentally to produce alerting effects, suppress melatonin, and phase-shift the biological clock. A few reports have shown that these devices suppress melatonin levels, but little is known about the effects on circadian phase or the following sleep episode, exposing a substantial gap in our knowledge of how this increasingly popular technology affects sleep. Here we compare the biological effects of reading an electronic book on a light-emitting device (LE-eBook) with reading a printed book in the hours before bedtime. Participants reading an LE-eBook took longer to fall asleep and had reduced evening sleepiness, reduced melatonin secretion, later timing of their circadian clock, and reduced next-morning alertness than when reading a printed book. These results demonstrate that evening exposure to an LE-eBook phase-delays the circadian clock, acutely suppresses melatonin, and has important implications for understanding the impact of such technologies on sleep, performance, health, and safety.

  10. Hypoglycemic Accuracy and Improved Low Glucose Alerts of the Latest Dexcom G4 Platinum Continuous Glucose Monitoring System.

    PubMed

    Peyser, Thomas A; Nakamura, Katherine; Price, David; Bohnett, Lucas C; Hirsch, Irl B; Balo, Andrew

    2015-08-01

    Accuracy of continuous glucose monitoring (CGM) devices in hypoglycemia has been a widely reported shortcoming of this technology. We report the accuracy in hypoglycemia of a new version of the Dexcom (San Diego, CA) G4 Platinum CGM system (software 505) and present results regarding the optimum setting of CGM hypoglycemic alerts. CGM values were compared with YSI analyzer (YSI Life Sciences, Yellow Springs, OH) measurements every 15 min. We reviewed the accuracy of the CGM system in the hypoglycemic range using standard metrics. We analyzed the time required for the CGM system to detect biochemical hypoglycemia (70 mg/dL) compared with the YSI with alert settings at 70 mg/dL and 80 mg/dL. We also analyzed the time between the YSI value crossing 55 mg/dL, defined as the threshold for cognitive impairment due to hypoglycemia, and when the CGM system alerted for hypoglycemia. The mean absolute difference for a glucose level of less than 70 mg/dL was 6 mg/dL. Ninety-six percent of CGM values were within 20 mg/dL of the YSI values between 40 and 80 mg/dL. When the CGM hypoglycemic alert was set at 80 mg/dL, the device provided an alert for biochemical hypoglycemia within 10 min in 95% of instances and at least a 10-min advance warning before the cognitive impairment threshold in 91% of instances in the study. Use of an 80 mg/dL threshold setting for hypoglycemic alerts on the G4 Platinum (software 505) may provide patients with timely warning of hypoglycemia before the onset of cognitive impairment, enabling them to treat themselves for hypoglycemia with fast-acting carbohydrates and prevent neuroglycopenia associated with very low glucose levels.

  11. Acute Kidney Injury in the Era of the AKI E-Alert

    PubMed Central

    Holmes, Jennifer; Rainer, Timothy; Geen, John; Roberts, Gethin; May, Kate; Wilson, Nick; Williams, John D.

    2016-01-01

    Background and objectives Our aim was to use a national electronic AKI alert to define the incidence and outcome of all episodes of community– and hospital–acquired adult AKI. Design, setting, participants, & measurements A prospective national cohort study was undertaken in a population of 3.06 million. Data were collected between March of 2015 and August of 2015. All patients with adult (≥18 years of age) AKI were identified to define the incidence and outcome of all episodes of community- and hospital-acquired AKI in adults. Mortality and renal outcomes were assessed at 90 days. Results There was a total of 31,601 alerts representing 17,689 incident episodes, giving an incidence of AKI of 577 per 100,000 population. Community-acquired AKI accounted for 49.3% of all incident episodes, and 42% occurred in the context of preexisting CKD (Chronic Kidney Disease Epidemiology Collaboration eGFR); 90-day mortality rate was 25.6%, and 23.7% of episodes progressed to a higher AKI stage than the stage associated with the alert. AKI electronic alert stage and peak AKI stage were associated with mortality, and mortality was significantly higher for hospital-acquired AKI compared with alerts generated in a community setting. Among patients who survived to 90 days after the AKI electronic alert, those who were not hospitalized had a lower rate of renal recovery and a greater likelihood of developing an eGFR<60 ml/min per 1.73 m2 for the first time, which may be indicative of development of de novo CKD. Conclusions The reported incidence of AKI is far greater than the previously reported incidence in studies reliant on clinical identification of adult AKI or hospital coding data. Although an electronic alert system is Information Technology driven and therefore, lacks intelligence and clinical context, these data can be used to identify deficiencies in care, guide the development of appropriate intervention strategies, and provide a baseline against which the effectiveness of these interventions may be measured. PMID:27793961

  12. Best practices: an electronic drug alert program to improve safety in an accountable care environment.

    PubMed

    Griesbach, Sara; Lustig, Adam; Malsin, Luanne; Carley, Blake; Westrich, Kimberly D; Dubois, Robert W

    2015-04-01

    The accountable care organization (ACO), one of the most promising and talked about new models of care, focuses on improving communication and care transitions by tying potential shared savings to specific clinical and financial benchmarks. An important factor in meeting these benchmarks is an ACO's ability to manage medications in an environment where medical and pharmacy care has been integrated. The program described in this article highlights the critical components of Marshfield Clinic's Drug Safety Alert Program (DSAP), which focuses on prioritizing and communicating safety issues related to medications with the goal of reducing potential adverse drug events. Once the medication safety concern is identified, it is reviewed to evaluate whether an alert warrants sending prescribers a communication that identifies individual patients or a general communication to all physicians describing the safety concern. Instead of basing its decisions regarding clinician notification about drug alerts on subjective criteria, the Marshfield Clinic's DSAP uses an internally developed scoring system. The scoring system includes criteria developed from previous drug alerts, such as level of evidence, size of population affected, severity of adverse event identified or targeted, litigation risk, available alternatives, and potential for duration of medication use. Each of the 6 criteria is assigned a weight and is scored based upon the content and severity of the alert received.  In its first 12 months, the program targeted 6 medication safety concerns involving the following medications: topiramate, glyburide, simvastatin, citalopram, pioglitazone, and lovastatin. Baseline and follow-up prescribing data were gathered on the targeted medications. Follow-up review of prescribing data demonstrated that the DSAP provided quality up-to-date safety information that led to changes in drug therapy and to decreases in potential adverse drug events. In aggregate, nearly 10,000 total potential adverse drug events were identified with baseline data from the DSAP initiatives, and nearly 8,000 were resolved by changes in prescribing.  Implications and additional thoughts from The Working Group on Optimizing Medication Therapy in Value-Based Healthcare were provided for the following categories: leveraging electronic health records, importance of data collection and reassessment, preventing alert fatigue utilizing various techniques, relevance to ACO quality measurement, and limitations of a retrospective system. While health information technologies have been recognized as a cornerstone for an ACO's success, additional research is needed on comparing these types of technological innovations. Future research should focus on reviewing comparable scoring criteria and alert systems utilized in a variety of ACOs. In addition, an examination of different data mining procedures used within different electronic health record platforms would prove useful to ACOs looking to improve the care of not only the subpopulations with specific metrics associated with them, but their patient population as a whole. The authors also highlight the need for additional research on health information exchanges, including the cost and resource requirements needed to successfully participate in these types of networks.

  13. Technology utilization to prevent medication errors.

    PubMed

    Forni, Allison; Chu, Hanh T; Fanikos, John

    2010-01-01

    Medication errors have been increasingly recognized as a major cause of iatrogenic illness and system-wide improvements have been the focus of prevention efforts. Critically ill patients are particularly vulnerable to injury resulting from medication errors because of the severity of illness, need for high risk medications with a narrow therapeutic index and frequent use of intravenous infusions. Health information technology has been identified as method to reduce medication errors as well as improve the efficiency and quality of care; however, few studies regarding the impact of health information technology have focused on patients in the intensive care unit. Computerized physician order entry and clinical decision support systems can play a crucial role in decreasing errors in the ordering stage of the medication use process through improving the completeness and legibility of orders, alerting physicians to medication allergies and drug interactions and providing a means for standardization of practice. Electronic surveillance, reminders and alerts identify patients susceptible to an adverse event, communicate critical changes in a patient's condition, and facilitate timely and appropriate treatment. Bar code technology, intravenous infusion safety systems, and electronic medication administration records can target prevention of errors in medication dispensing and administration where other technologies would not be able to intercept a preventable adverse event. Systems integration and compliance are vital components in the implementation of health information technology and achievement of a safe medication use process.

  14. Integrating UF6 Cylinder RF Tracking With Continuous Load Cell Monitoring for Verifying Declared UF6 Feed and Withdrawal Operations Verifying Declared UF6 Feed and Withdrawal Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krichinsky, Alan M; Miller, Paul; Pickett, Chris A

    2009-01-01

    Oak Ridge National Laboratory is demonstrating the integration of UF6 cylinder tracking, using RF technology, with continuous load cell monitoring (CLCM) at mock UF6 feed and withdrawal (F&W) stations. CLCM and cylinder tracking are two of several continuous-monitoring technologies that show promise in providing integrated safeguards of F&W operations at enrichment plants. Integrating different monitoring technologies allows advanced, automated event processing to screen innocuous events thereby minimizing false alerts to independent inspectors. Traditionally, international inspectors rely on batch verification of material inputs and outputs derived from operator declarations and periodic on-site inspections at uranium enrichment plants or other nuclear processingmore » facilities. Continuously monitoring F&W activities between inspections while providing filtered alerts of significant operational events will substantially increase the amount of valuable information available to inspectors thereby promising to enhance the effectiveness of safeguards and to improve efficiency in conducting on-site inspections especially at large plants for ensuring that all operations are declared.« less

  15. The effectiveness of computerized drug-lab alerts: a systematic review and meta-analysis.

    PubMed

    Bayoumi, Imaan; Al Balas, Mosab; Handler, Steven M; Dolovich, Lisa; Hutchison, Brian; Holbrook, Anne

    2014-06-01

    Inadequate lab monitoring of drugs is a potential cause of ADEs (adverse drug events) which is remediable. To determine the effectiveness of computerized drug-lab alerts to improve medication-related outcomes. Citations from the Computerized Clinical Decision Support System Systematic Review (CCDSSR) and MMIT (Medications Management through Health Information Technology) databases, which had searched MEDLINE, EMBASE, CINAHL, Cochrane Database of Systematic Reviews, International Pharmaceutical Abstracts from 1974 to March 27, 2013. Randomized controlled trials (RCTs) of clinician-targeted computerized drug lab alerts conducted in any healthcare setting. Two reviewers performed full text review to determine study eligibility. A single reviewer abstracted data and evaluated validity of included studies using Cochrane handbook domains. Thirty-six studies met the inclusion criteria (25 single drug studies with 22,504 participants, 14 targeting anticoagulation; 11 multi-drug studies with 56,769 participants). ADEs were reported as an outcome in only four trials, all targeting anticoagulants. Computerized drug-lab alerts did not reduce ADEs (OR 0.89, 95% CI 0.79-1.00, p=0.05), length of hospital stay (SMD 0.00, 95%CI -0.93 to 0.93, p=0.055, 1 study), likelihood of hypoglycemia (OR 1.29, 95% CI 0.31-5.37) or likelihood of bleeding, but were associated with increased likelihood of prescribing changes (OR 1.73, 95% CI 1.21-2.47) or lab monitoring (OR 1.47, 95% confidence interval 1.12-1.94) in accordance with the alert. There is no evidence that computerized drug-lab alerts are associated with important clinical benefits, but there is evidence of improvement in selected clinical surrogate outcomes (time in therapeutic range for vitamin K antagonists), and changes in process outcomes (lab monitoring and prescribing decisions). Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Terrain Display Alternatives Assessment of Information Density and Alerting Strategies

    DOT National Transportation Integrated Search

    1998-04-01

    Current technology makes it possible to display navigation and terrain information on electronic : screens in the cockpit. The conventions used for position and terrain information must be clearly : presented so pilots can maintain their positional a...

  17. Building a Communication, Education, an Outreach Program for the ShakeAlert National Earthquake Early Warning Program

    NASA Astrophysics Data System (ADS)

    DeGroot, R. M.; Strauss, J. A.; Given, D. D.; Cochran, E. S.; Burkett, E. R.; Long, K.

    2016-12-01

    Earthquake Early Warning (EEW) systems can provide as much as tens of seconds of warning to people and automated systems before strong shaking arrives. The United States Geological Survey (USGS) and its partners are developing an EEW system for the West Coast of the United States. To be an integral part of successful implementation, EEW engagement programs and materials must integrate with and leverage broader earthquake risk programs. New methods and products for dissemination must be multidisciplinary, cost effective, and consistent with existing hazards education efforts. Our presentation outlines how the USGS and its partners will approach this effort in the context of the EEW system through the work of a multistate and multiagency committee that participates in the design, implementation, and evaluation of a portfolio of programs and products. This committee, referred to as the ShakeAlert Joint Committee for Communication, Education, and Outreach (ShakeAlert CEO), is working to identify, develop, and cultivate partnerships with EEW stakeholders including Federal, State, academic partners, private companies, policy makers, and local organizations. Efforts include developing materials, methods for delivery, and reaching stakeholders with information on EEW, earthquake preparedness, and emergency protective actions. It is essential to develop standards to ensure information communicated via the EEW alerts is consistent across the public and private sector and achieving a common understanding of what actions users take when they receive an EEW warning. The USGS and the participating states and agencies acknowledge that the implementation of EEW is a collective effort requiring the participation of hundreds of stakeholders committed to ensuring public accessibility.

  18. ShakeAlert—An earthquake early warning system for the United States west coast

    USGS Publications Warehouse

    Burkett, Erin R.; Given, Douglas D.; Jones, Lucile M.

    2014-08-29

    Earthquake early warning systems use earthquake science and the technology of monitoring systems to alert devices and people when shaking waves generated by an earthquake are expected to arrive at their location. The seconds to minutes of advance warning can allow people and systems to take actions to protect life and property from destructive shaking. The U.S. Geological Survey (USGS), in collaboration with several partners, has been working to develop an early warning system for the United States. ShakeAlert, a system currently under development, is designed to cover the West Coast States of California, Oregon, and Washington.

  19. Responder Technology Alert Monthly (January 2015)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Upton, Jaki F.; Stein, Steven L.

    As part of technology foraging for the Responder Technology Alliance, established by the Department of Homeland Science and Technologies First Responders Group, this report summarizes technologies that are relevant in the area of “wearables,” with the potential for use by first responders. The content was collected over the previous month(s) and reproduced from a general Internet search using the term wearables. Additional information is available at the websites provided. This report is not meant to be an exhaustive list nor an endorsement of any technology described herein. Rather, it is meant to provide useful information about current developments in themore » areas wearable technology.« less

  20. Responder Technology Alert (February 2015)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Upton, Jaki F.; Stein, Steven L.

    2015-04-10

    As part of technology foraging for the Responder Technology Alliance, established by the Department of Homeland Science and Technologies First Responders Group, this report summarizes technologies that are relevant in the area of “wearables,” with the potential for use by first responders. The content was collected over the previous month(s) and reproduced from a general Internet search using the term wearables. Additional information is available at the websites provided. This report is not meant to be an exhaustive list nor an endorsement of any technology described herein. Rather, it is meant to provide useful information about current developments in themore » areas wearable technology.« less

  1. Responder Technology Alert Monthly (Oct-Nov 2014)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Upton, Jaki F.; Stein, Steven L.

    As part of technology foraging for the Responder Technology Alliance, established by the Department of Homeland Science and Technologies First Responders Group, this report summarizes technologies that are relevant in the area of “wearables,” with the potential for use by first responders. The content was collected over the previous month(s) and reproduced from a general Internet search using the term wearables. Additional information is available at the websites provided. This report is not meant to be an exhaustive list nor an endorsement of any technology described herein. Rather, it is meant to provide useful information about current developments in themore » areas wearable technology.« less

  2. Afterschool: Middle School and Science, Technology, Engineering and Math (STEM). MetLife Foundation Afterschool Alert. Issue Brief No. 44

    ERIC Educational Resources Information Center

    Afterschool Alliance, 2010

    2010-01-01

    The 21st Century's information economy has been creating more jobs that require not only a college education but also a fair amount of expertise in the fields of science, technology, engineering and math--collectively known as STEM. The last several decades have seen the industrial- and manufacturing-based economy shift to a service economy fueled…

  3. 48 CFR 352.239-72 - Security requirements for Federal information technology resources.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Federal information technology resources. 352.239-72 Section 352.239-72 Federal Acquisition Regulations... Provisions and Clauses 352.239-72 Security requirements for Federal information technology resources. As... Federal Information Technology Resources (January 2010) (a) Applicability. This clause applies whether the...

  4. Identifying new technologies that save energy and reduce costs to the Federal sector: The New Technology Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunt, W.D.M.; Conover, D.R.; Stockmeyer, M.K.

    1995-11-01

    In 1990 the New Technology Demonstration Program (formerly the Test Bed Demonstration Program) was initiated by the US Department of Energy`s Office (DOE`s) of Federal Energy Management Programs with the purpose of accelerating the introduction of new technologies into the Federal sector. The program has since expanded into a multi-laboratory collaborative effort that evaluates new technologies and shares the results with the Federal design and procurement communities. These evaluations are performed on a collaborative basis which typically includes technology manufacturers, Federal facilities, utilities, trade associations, research institutes, and other in partnership with DOE. The end result is a range ofmore » effective technology transfer tools that provide operations and performance data on new technologies to Federal designers, building managers, and procurement officials. These tools assist in accelerating a technology`s Federal application and realizing reductions in energy consumption and costs.« less

  5. The Advanced Linked Extended Reconnaissance & Targeting Technology Demonstration project

    NASA Astrophysics Data System (ADS)

    Edwards, Mark

    2008-04-01

    The Advanced Linked Extended Reconnaissance & Targeting (ALERT) Technology Demonstration (TD) project is addressing many operational needs of the future Canadian Army's Surveillance and Reconnaissance forces. Using the surveillance system of the Coyote reconnaissance vehicle as an experimental platform, the ALERT TD project aims to significantly enhance situational awareness by fusing multi-sensor and tactical data, developing automated processes, and integrating beyond line-of-sight sensing. The project is exploiting important advances made in computer processing capability, displays technology, digital communications, and sensor technology since the design of the original surveillance system. As the major research area within the project, concepts are discussed for displaying and fusing multi-sensor and tactical data within an Enhanced Operator Control Station (EOCS). The sensor data can originate from the Coyote's own visible-band and IR cameras, laser rangefinder, and ground-surveillance radar, as well as from beyond line-of-sight systems such as mini-UAVs and unattended ground sensors. Video-rate image processing has been developed to assist the operator to detect poorly visible targets. As a second major area of research, automatic target cueing capabilities have been added to the system. These include scene change detection, automatic target detection and aided target recognition algorithms processing both IR and visible-band images to draw the operator's attention to possible targets. The merits of incorporating scene change detection algorithms are also discussed. In the area of multi-sensor data fusion, up to Joint Defence Labs level 2 has been demonstrated. The human factors engineering aspects of the user interface in this complex environment are presented, drawing upon multiple user group sessions with military surveillance system operators. The paper concludes with Lessons Learned from the project. The ALERT system has been used in a number of C4ISR field trials, most recently at Exercise Empire Challenge in China Lake CA, and at Trial Quest in Norway. Those exercises provided further opportunities to investigate operator interactions. The paper concludes with recommendations for future work in operator interface design.

  6. The RHESA-CARE study: an extended baseline survey of the regional myocardial infarction registry of Saxony-Anhalt (RHESA) design and objectives.

    PubMed

    Hirsch, Katharina; Bohley, Stefanie; Mau, Wilfried; Schmidt-Pokrzywniak, Andrea

    2016-08-17

    Cardiovascular disease (CVD) is a leading cause of death in Europe. In Germany, a declining mortality rate from acute myocardial infarction (AMI) has been observed in the last decades. Nevertheless, there are large differences between the federal states when looking at the mortality and morbidity of AMI. Saxony-Anhalt is one of the federal states with the highest mortality rates for AMI in Germany. In 2012, the regional myocardial infarction registry of Saxony-Anhalt (RHESA) was established to investigate the individual, infrastructural, and health care factors with respect to an urban (city of Halle) and rural (region of Altmark) population. For detailed observation the RHESA-CARE study was conducted in 2014. RHESA-CARE focuses on the symptoms during infarction, the behaviour of patients while alerting for infarction, the use of rehabilitation possibilities, and long-term care. RHESA-CARE is an extended baseline survey of AMI patients registered in RHESA who are aged 25 or more, and inhabitants of the city of Halle (Saale) or the district of Altmark in the federal state of Saxony-Anhalt, Germany. Detailed information was collected on classical and psychosocial cardiovascular risk factors as well as factors of alerting behaviour, first aid, and utilization of medical and rehabilitation services. High data quality is ensured by a detailed system of quality control. RHESA-CARE has the main objective to investigate factors that influence morbidity and mortality rates due to AMI. Another purpose is the comparison of a rural and urban patient population. It provides an opportunity to serve as a base for improvement of patients' behaviour and health care as well as further research.

  7. Initial Evaluation of a Conflict Detection Tool in the Terminal Area

    NASA Technical Reports Server (NTRS)

    Verma Savita Arora; Tang, Huabin; Ballinger, Deborah S.; Kozon, Thomas E.; Farrahi, Amir Hossein

    2012-01-01

    Despite the recent economic recession and its adverse impact on air travel, the Federal Aviation Administration (FAA) continues to forecast an increase in air traffic demand that may see traffic double or triple by the year 2025. Increases in air traffic will burden the air traffic management system, and higher levels of safety and efficiency will be required. The air traffic controllers primary task is to ensure separation between aircraft in their airspace and keep the skies safe. As air traffic is forecasted to increase in volume and complexity [1], there is an increased likelihood of conflicts between aircraft, which adds risk and inefficiency to air traffic management and increases controller workload. To attenuate these factors, recent ATM research has shown that air and ground-based automation tools could reduce controller workload, especially if the automation is focused on conflict detection and resolution. Conflict Alert is a short time horizon conflict detection tool deployed in the Terminal Radar Approach Control (TRACON), which has limited utility due to the high number of false alerts generated and its use of dead reckoning to predict loss of separation between aircraft. Terminal Tactical Separation Assurance Flight Environment (T-TSAFE) is a short time horizon conflict detection tool that uses both flight intent and dead reckoning to detect conflicts. Results of a fast time simulation experiment indicated that TTSAFE provided a more effective alert lead-time and generated less false alerts than Conflict Alert [2]. TSAFE was previously tested in a Human-In-The-Loop (HITL) simulation study that focused on the en route phase of flight [3]. The current study tested the T-TSAFE tool in an HITL simulation study, focusing on the terminal environment with current day operations. The study identified procedures, roles, responsibilities, information requirements and usability, with the help of TRACON controllers who participated in the experiment. Metrics such as lead alert time, alert response time, workload, situation awareness and other measures were statistically analyzed. These metrics were examined from an overall perspective and comparisons between conditions (altitude resolutions via keyboard entry vs. ADS-B entry) and controller positions (two final approach sectors and two feeder sectors) were also examined. Results of these analyses and controller feedback provided evidence of T-TSAFE s potential promise as a useful air traffic controller tool. Heuristic analysis also provided information on ways in which the T-TSAFE tool can be improved. Details of analyses results will be presented in the full paper.

  8. Implementing a national early awareness and alert system for new and emerging health technologies in Italy: the COTE Project.

    PubMed

    Migliore, Antonio; Perrini, Maria Rosaria; Jefferson, Tom; Cerbo, Marina

    2012-07-01

    The aim of this study was to establish a national Early Awareness and Alert (EAA) system for the identification and assessment of new and emerging health technologies in Italy. In 2008, Agenas, a public body supporting Regions and the Ministry of Health (MoH) in health services research, started a project named COTE (Observatory of New and Emerging Health Technologies) with the ultimate aim of implementing a national EAA system. The COTE project involved all stakeholders (MoH, Regions, Industry, Universities, technical government bodies, and Scientific Societies), in defining the key characteristics and methods of the EAA system. Agreement with stakeholders was reached using three separate workshops. During the workshops, participants shared and agreed methods for identification of new and emerging health technologies, prioritization, and assessment. The structure of the Horizon Scanning (HS) reports was discussed and defined. The main channels for dissemination of outputs were identified as the EuroScan database, and the stakeholders' Web portals. During the final workshop, Agenas presented the first three HS reports produced at national level and proposed the establishment of a permanent national EAA system. The COTE Project created the basis for a permanent national EAA system in Italy. An infrastructure to enable the stakeholders network to grow was created, methods to submit new and emerging health technologies for possible evaluation were established, methods for assessment of the technologies selected were defined, and the stakeholders involvement was delineated (in the identification, assessment, and dissemination stages).

  9. Examining the Role of Metadata in Testing IED Detection Systems

    DTIC Science & Technology

    2009-09-01

    energy management, crop assessment, weather forecasting, disaster alerts, and endangered species assessment [ Biagioni and Bridges 2002; Main- waring et...accessed June 10, 2008). Biagioni , E. and K. Bridges. 2002. The application of remote sensor technology to assist the recovery of rare endangered species

  10. Evaluation of the COMETT Programme.

    ERIC Educational Resources Information Center

    Thompson, Quentin; Ambler, Mark

    1990-01-01

    The evaluation report of the European Community Action Programme for Education and Training for Technology (COMETT) examines COMETT program content, COMETT projects, and initial program impact. It was concluded that COMETT has alerted the educational sector and industry to benefits of cooperative training but that transnational cooperative…

  11. Improving Environmental Literacy through GO3 Citizen Science Project

    NASA Astrophysics Data System (ADS)

    Wilkening, B.

    2011-12-01

    In the Global Ozone (GO3) Project students measure ground-level ozone on a continuous basis and upload their results to a global network used by atmospheric scientists and schools. Students learn important concepts such as chemical measurement methods; instrumentation; calibration; data acquisition using computers; data quality; statistics; data analysis and graphing; posting of data to the web; the chemistry of air pollution; stratospheric ozone depletion and global climate change. Students collaborate with researchers and other students globally in the GO3 network. Wilson K-8 School is located in a suburban area in Pima County, Arizona. Throughout the year we receive high ozone alert days. Prior to joining the GO3 project, my students were unaware of air pollution alerts, risks and causes. In the past when Pima County issued alerts to the school, they were posted on signs around the school. No explanation was provided to the students and the signs were often left up for days. This discounted the potential health effects of the situation, resulting in the alerts effectively being ignored. The GO3 project is transforming both my students and our school community. Now my students are:

    • Performing science research
    • Utilizing technology and increasing their skills
    • Collaborating in a responsible manner on the global GO3 social network
    • Communicating their work to the community
    • Issuing their own ozone alerts to their school
    • Advocating for actions that will improve air quality
    My students participation in this citizen science project is creating a more cognizant and active community in regards to air pollution.

  12. The Generic Resolution Advisor and Conflict Evaluator (GRACE) for Detect-And-Avoid (DAA) Systems

    NASA Technical Reports Server (NTRS)

    Abramson, Michael; Refai, Mohamad; Santiago, Confesor

    2017-01-01

    The paper describes the Generic Resolution Advisor and Conflict Evaluator (GRACE), a novel alerting and guidance algorithm that combines flexibility, robustness, and computational efficiency. GRACE is "generic" in that it makes no assumptions regarding temporal or spatial scales, aircraft performance, or its sensor and communication systems. Accordingly, GRACE is well suited to research applications where alerting and guidance is a central feature and requirements are fluid involving a wide range of aviation technologies. GRACE has been used at NASA in a number of real-time and fast-time experiments supporting evolving requirements of DAA research, including parametric studies, NAS-wide simulations, human-in-the-loop experiments, and live flight tests.

  13. Simulator Evaluation of Runway Incursion Prevention Technology for General Aviation Operations

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.; Prinzel, Lawrence J., III

    2011-01-01

    A Runway Incursion Prevention System (RIPS) has been designed under previous research to enhance airport surface operations situation awareness and provide cockpit alerts of potential runway conflict, during transport aircraft category operations, in order to prevent runway incidents while also improving operations capability. This study investigated an adaptation of RIPS for low-end general aviation operations using a fixed-based simulator at the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC). The purpose of the study was to evaluate modified RIPS aircraft-based incursion detection algorithms and associated alerting and airport surface display concepts for low-end general aviation operations. This paper gives an overview of the system, simulation study, and test results.

  14. Runway Incursion Prevention System Simulation Evaluation

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.

    2002-01-01

    A Runway Incursion Prevention System (RIPS) was evaluated in a full mission simulation study at the NASA Langley Research center in March 2002. RIPS integrates airborne and ground-based technologies to provide (1) enhanced surface situational awareness to avoid blunders and (2) alerts of runway conflicts in order to prevent runway incidents while also improving operational capability. A series of test runs was conducted in a high fidelity simulator. The purpose of the study was to evaluate the RIPS airborne incursion detection algorithms and associated alerting and airport surface display concepts. Eight commercial airline crews participated as test subjects completing 467 test runs. This paper gives an overview of the RIPS, simulation study, and test results.

  15. A New GRB follow-up Software at TUG

    NASA Astrophysics Data System (ADS)

    Dindar, M.; Parmaksizoglu, M.; Helhel, S.; Esenoglu, H.; Kirbiyik, H.

    2016-12-01

    A gamma-ray burst (GRB) optical photometric follow-up system at TUBITAK (Scientic and Technological Research Council of Turkey) National Observatory (TUG) has been planned. It uses the 0.6 m Telescope (T60) and can automatically respond to GRB Coordinates Network (GCN) alerts. The telescopes slew relatively fast, being able to point to a new target field within 30 s upon a request. Whenever available, the 1 m T100 and 2.5 m RTT150 telescopes will be used in the future. As an example in 2015, the GRB software system (will be server side) at T60-telescope responded to GRB alert and started the observation as early as 129 s after the GRB trigger autonomously.

  16. Operational Space Weather Activities in the US

    NASA Astrophysics Data System (ADS)

    Berger, Thomas; Singer, Howard; Onsager, Terrance; Viereck, Rodney; Murtagh, William; Rutledge, Robert

    2016-07-01

    We review the current activities in the civil operational space weather forecasting enterprise of the United States. The NOAA/Space Weather Prediction Center is the nation's official source of space weather watches, warnings, and alerts, working with partners in the Air Force as well as international operational forecast services to provide predictions, data, and products on a large variety of space weather phenomena and impacts. In October 2015, the White House Office of Science and Technology Policy released the National Space Weather Strategy (NSWS) and associated Space Weather Action Plan (SWAP) that define how the nation will better forecast, mitigate, and respond to an extreme space weather event. The SWAP defines actions involving multiple federal agencies and mandates coordination and collaboration with academia, the private sector, and international bodies to, among other things, develop and sustain an operational space weather observing system; develop and deploy new models of space weather impacts to critical infrastructure systems; define new mechanisms for the transition of research models to operations and to ensure that the research community is supported for, and has access to, operational model upgrade paths; and to enhance fundamental understanding of space weather through support of research models and observations. The SWAP will guide significant aspects of space weather operational and research activities for the next decade, with opportunities to revisit the strategy in the coming years through the auspices of the National Science and Technology Council.

  17. Influence of satellite alerts on the efficiency of aircraft monitoring of maritime oil pollution in German waters

    NASA Astrophysics Data System (ADS)

    Helmke, Peer; Baschek, Björn; Hunsänger, Thomas; Kranz, Susanne

    2014-10-01

    For detecting accidental and illegal pollution by mineral oil, the German exclusive economic zone and surrounding waters have been monitored by aircraft operationally for more than 25 years. Aircraft surveillance uses predominantly Side-Looking-Airborne-Radar for visualization of the effect of oil to smoothen capillary waves. A set of near range sensors complements the remote sensing data available for the human operator to classify the detected features as "mineral oil", "natural phenomenon", "other substance" or "unknown" pollution. Today, as an add-on to aerial surveillance, the German Central Command of Maritime Emergencies uses the operational satellite service "CleanSeaNet" provided by the European Maritime Safety Agency: Radar satellite data is analyzed in near real time and alerts of potential pollution are sent out. Shortly after receiving the results, aircraft surveillance flights are started by the 3rd Naval Air Wing and the locations of the satellite alerts are checked. Thus, a combined system of satellite and aerial surveillance is in place. The German Federal Institute of Hydrology, BfG, has access to the data of the pollution events detected during these flights and the corresponding meta-data of flights and satellite images. In this work, a period of two years of this data is analyzed. The probability to detect pollutions is evaluated for (A) flight missions associated with satellite scenes, and (B) additional flights performed independently from satellite scenes. Thus, the influence of satellite alerts on the efficiency of aircraft monitoring is investigated. Coverage and coordination of the monitoring by aircraft and satellite are assessed and implications for the operational monitoring are discussed.

  18. Flight Deck Display Technologies for 4DT and Surface Equivalent Visual Operations

    NASA Technical Reports Server (NTRS)

    Prinzel, Lawrence J., III; Jones, Denis R.; Shelton, Kevin J.; Arthur, Jarvis J., III; Bailey, Randall E.; Allamandola, Angela S.; Foyle, David C.; Hooey, Becky L.

    2009-01-01

    NASA research is focused on flight deck display technologies that may significantly enhance situation awareness, enable new operating concepts, and reduce the potential for incidents/accidents for terminal area and surface operations. The display technologies include surface map, head-up, and head-worn displays; 4DT guidance algorithms; synthetic and enhanced vision technologies; and terminal maneuvering area traffic conflict detection and alerting systems. This work is critical to ensure that the flight deck interface technologies and the role of the human participants can support the full realization of the Next Generation Air Transportation System (NextGen) and its novel operating concepts.

  19. Signal Processing in Reverberation- A Summary of Performance Capability

    DTIC Science & Technology

    1972-08-30

    34 LkP+52-DOGLB. UNCLASSIFIED N, TM No. TC- 173-72 LC INAVAL UNDERWATER SYSTEMS CENTER Technical Memorandum SIGNAL PROCESSING IN REVERBERATION- A...SUMMARY OF PERFORMANCE CAPABILITY Date: 30 August 1972 Prepared by: -- v i Alert H. Nuttall Office of the Director of Science and Technology 2TICELECTEI...Nuffall Office of the Director of Science and Technology Approved for public release; distribution unlimited UNCLASSIFIED TM No. TC- I7P-72 NAVAL

  20. Conceptual model for collision detection and avoidance for runway incursion prevention

    NASA Astrophysics Data System (ADS)

    Latimer, Bridgette A.

    The Federal Aviation Administration (FAA), National Transportation and Safety Board (NTSB), National Aeronautics and Space Administration (NASA), numerous corporate entities, and research facilities have each come together to determine ways to make air travel safer and more efficient. These efforts have resulted in the development of a concept known as the Next Generation (Next Gen) of Aircraft or Next Gen. The Next Gen concept promises to be a clear departure from the way in which aircraft operations are performed today. The Next Gen initiatives require that modifications are made to the existing National Airspace System (NAS) concept of operations, system level requirements, software (SW) and hardware (HW) requirements, SW and HW designs and implementations. A second example of the changes in the NAS is the shift away from air traffic controllers having the responsibility for separation assurance. In the proposed new scheme of free flight, each aircraft would be responsible for assuring that it is safely separated from surrounding aircraft. Free flight would allow the separation minima for enroute aircraft to be reduced from 2000 nautical miles (nm) to 1000 nm. Simply put "Free Flight is a concept of air traffic management that permits pilots and controllers to share information and work together to manage air traffic from pre-flight through arrival without compromising safety [107]." The primary goal of this research project was to create a conceptual model that embodies the essential ingredients needed for a collision detection and avoidance system. This system was required to operate in two modes: air traffic controller's perspective and pilot's perspective. The secondary goal was to demonstrate that the technologies, procedures, and decision logic embedded in the conceptual model were able to effectively detect and avoid collision risks from both perspectives. Embodied in the conceptual model are five distinct software modules: Data Acquisition, State Processor, Projection, Collision Detection, and Alerting and Resolution. The underlying algorithms in the Projection module are linear projection and Kalman filtering which are used to estimate the future state of the aircraft. The Resolution and Alerting module is comprised of two algorithms: a generic alerting algorithm and the potential fields algorithm [71]. The conceptual model was created using Enterprise Architect RTM and MATLAB RTM was used to code the methods and to simulate conflict scenarios.

  1. E-Learning. Trends and Issues Alert.

    ERIC Educational Resources Information Center

    Imel, Susan

    Electronic learning, also known as e-learning, is generally defined as instruction and learning experiences that are delivered via electronic technology such as the Internet, audiotape and videotape, satellite broadcast, interactive television, and CD-ROM. Web-based learning, computer-based learning, and virtual classrooms are some of the…

  2. Crew interface with windshear systems

    NASA Technical Reports Server (NTRS)

    Carbaugh, Dave

    1988-01-01

    A review is given of the areas within Boeing that are working on the NASA contract to conduct windshear studies. A synopsis is given of the work that Boeing Flight Deck Research is doing. A short review of nuisance and alerts is given in light of upcoming forward look technology.

  3. Voice Enabled Framework to Support Post-Surgical Discharge Monitoring

    PubMed Central

    Blansit, Kevin; Marmor, Rebecca; Zhao, Beiqun; Tien, Dan

    2017-01-01

    Unplanned surgical readmissions pose a challenging problem for the American healthcare system. We propose to combine consumer electronic voice recognition technology with the FHIR standard to create a post-surgical discharge monitoring app to identify and alert physicians to a patient’s deteriorating status. PMID:29854267

  4. Applications of aerospace technology in industry, a technology transfer profile: Fire safety

    NASA Technical Reports Server (NTRS)

    Kottenstette, J. P.; Freeman, J. E.; Heins, C. R.; Hildred, W. M.; Johnson, F. D.; Staskin, E. R.

    1971-01-01

    The fire safety field is considered as being composed of three parts: an industry, a technology base, and a user base. An overview of the field is presented, including a perspective on the magnitude of the national fire safety problem. Selected NASA contributions to the technology of fire safety are considered. Communication mechanisms, particularly conferences and publications, used by NASA to alert the community to new developments in the fire safety field, are reviewed. Several examples of nonaerospace applications of NASA-generated fire safety technology are also presented. Issues associated with attempts to transfer this technology from the space program to other sectors of the American economy are outlined.

  5. Alert dwell time: introduction of a measure to evaluate interruptive clinical decision support alerts

    PubMed Central

    McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras

    2016-01-01

    Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time—the time elapsed from when an interruptive alert is generated to when it is dismissed—could be calculated by using historical alert data from log files. Drug–drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1–4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < .001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < .001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. PMID:26499101

  6. Developing Software to “Track and Catch” Missed Follow-up of Abnormal Test Results in a Complex Sociotechnical Environment

    PubMed Central

    Smith, M.; Murphy, D.; Laxmisan, A.; Sittig, D.; Reis, B.; Esquivel, A.; Singh, H.

    2013-01-01

    Summary Background Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider’s prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up. Objectives The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. Methods We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA’s EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Results Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility’s “test” EHR system, thus demonstrating technical compatibility. Conclusion To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results. PMID:24155789

  7. Developing software to "track and catch" missed follow-up of abnormal test results in a complex sociotechnical environment.

    PubMed

    Smith, M; Murphy, D; Laxmisan, A; Sittig, D; Reis, B; Esquivel, A; Singh, H

    2013-01-01

    Abnormal test results do not always receive timely follow-up, even when providers are notified through electronic health record (EHR)-based alerts. High workload, alert fatigue, and other demands on attention disrupt a provider's prospective memory for tasks required to initiate follow-up. Thus, EHR-based tracking and reminding functionalities are needed to improve follow-up. The purpose of this study was to develop a decision-support software prototype enabling individual and system-wide tracking of abnormal test result alerts lacking follow-up, and to conduct formative evaluations, including usability testing. We developed a working prototype software system, the Alert Watch And Response Engine (AWARE), to detect abnormal test result alerts lacking documented follow-up, and to present context-specific reminders to providers. Development and testing took place within the VA's EHR and focused on four cancer-related abnormal test results. Design concepts emphasized mitigating the effects of high workload and alert fatigue while being minimally intrusive. We conducted a multifaceted formative evaluation of the software, addressing fit within the larger socio-technical system. Evaluations included usability testing with the prototype and interview questions about organizational and workflow factors. Participants included 23 physicians, 9 clinical information technology specialists, and 8 quality/safety managers. Evaluation results indicated that our software prototype fit within the technical environment and clinical workflow, and physicians were able to use it successfully. Quality/safety managers reported that the tool would be useful in future quality assurance activities to detect patients who lack documented follow-up. Additionally, we successfully installed the software on the local facility's "test" EHR system, thus demonstrating technical compatibility. To address the factors involved in missed test results, we developed a software prototype to account for technical, usability, organizational, and workflow needs. Our evaluation has shown the feasibility of the prototype as a means of facilitating better follow-up for cancer-related abnormal test results.

  8. Pilot Evaluations of Runway Status Light System

    NASA Technical Reports Server (NTRS)

    Young, Steven D.; Wills, Robert W.; Smith, R. Marshall

    1996-01-01

    This study focuses on use of the Transport Systems Research Vehicle (TSRV) Simulator at the Langley Research Center to obtain pilot opinion and input on the Federal Aviation Administration's Runway Status Light System (RWSL) prior to installation in an operational airport environment. The RWSL has been designed to reduce the likelihood of runway incursions by visually alerting pilots when a runway is occupied. Demonstrations of the RWSL in the TSRV Simulator allowed pilots to evaluate the system in a realistic cockpit environment.

  9. SisPorto 4.0 - computer analysis following the 2015 FIGO Guidelines for intrapartum fetal monitoring.

    PubMed

    Ayres-de-Campos, Diogo; Rei, Mariana; Nunes, Inês; Sousa, Paulo; Bernardes, João

    2017-01-01

    SisPorto 4.0 is the most recent version of a program for the computer analysis of cardiotocographic (CTG) signals and ST events, which has been adapted to the 2015 International Federation of Gynaecology and Obstetrics (FIGO) guidelines for intrapartum foetal monitoring. This paper provides a detailed description of the analysis performed by the system, including the signal-processing algorithms involved in identification of basic CTG features and the resulting real-time alerts.

  10. Minuteman III Cost Per Alert Hour Analysis

    DTIC Science & Technology

    2012-03-22

    Proverbs 16:3 I am eternally grateful for such a lovely wife and vibrant children; without your patience and support, I would...section. 12 Table 1: Alternative CPFH Factors H ild eb ra nt (1 99 0) W al la ce (2 00 0) Ki le y (2 00 1) Py le s (2 00 3) La ub ac he r (2 00 4...Installation Law Enforcement ( LE ) Operations. Installation LE Operations includes enforcing federal, state and military law, enforcing installation

  11. Construction and validation of the EEG analogues of the Karolinska sleepiness scale based on the Karolinska drowsiness test.

    PubMed

    Putilov, Arcady A; Donskaya, Olga G

    2013-07-01

    Simple methods of sleepiness assessment are greatly needed for both fundamental research and practical applications. The Karolinska drowsiness test (KDT) was applied to construct physiological alertness scales and to validate them against such well-known instrument of subjective sleepiness assessment as the Karolinska sleepiness scale (KSS). Seven-min EEG recordings were obtained with 2-h interval from frontal and occipital derivations during the last 32-50 h of 44-61-h wakefulness of 15 healthy study participants. Occipital alpha-theta power difference and frontal and occipital scores on the 2nd principal component of the EEG spectrum were calculated for each one-min interval of 5-min eyes closed section of the record. To obtain scores (from 0 to 5) on alertness scales for each of these EEG indexes, all positive one-min values of the index were assigned to 1, and all remaining (negative) values were assigned to 0. Scores on any of the physiological alertness scales were found to be strongly associated with KSS scores. Physiological analogues of KSS were offered by utilising the EEG recordings on eyes closed interval of KDT. The constructed physiological scales can help in improving validity and user-friendliness of the field and laboratory methods of quantification of drowsy state. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  12. Validating and Verifying Biomathematical Models of Human Fatigue

    NASA Technical Reports Server (NTRS)

    Martinez, Siera Brooke; Quintero, Luis Ortiz; Flynn-Evans, Erin

    2015-01-01

    Airline pilots experience acute and chronic sleep deprivation, sleep inertia, and circadian desynchrony due to the need to schedule flight operations around the clock. This sleep loss and circadian desynchrony gives rise to cognitive impairments, reduced vigilance and inconsistent performance. Several biomathematical models, based principally on patterns observed in circadian rhythms and homeostatic drive, have been developed to predict a pilots levels of fatigue or alertness. These models allow for the Federal Aviation Administration (FAA) and commercial airlines to make decisions about pilot capabilities and flight schedules. Although these models have been validated in a laboratory setting, they have not been thoroughly tested in operational environments where uncontrolled factors, such as environmental sleep disrupters, caffeine use and napping, may impact actual pilot alertness and performance. We will compare the predictions of three prominent biomathematical fatigue models (McCauley Model, Harvard Model, and the privately-sold SAFTE-FAST Model) to actual measures of alertness and performance. We collected sleep logs, movement and light recordings, psychomotor vigilance task (PVT), and urinary melatonin (a marker of circadian phase) from 44 pilots in a short-haul commercial airline over one month. We will statistically compare with the model predictions to lapses on the PVT and circadian phase. We will calculate the sensitivity and specificity of each model prediction under different scheduling conditions. Our findings will aid operational decision-makers in determining the reliability of each model under real-world scheduling situations.

  13. 48 CFR 352.239-72 - Security requirements for Federal information technology resources.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...' mission. The term “information technology (IT)”, as used in this clause, includes computers, ancillary... Federal information technology resources. 352.239-72 Section 352.239-72 Federal Acquisition Regulations... Provisions and Clauses 352.239-72 Security requirements for Federal information technology resources. As...

  14. 48 CFR 352.239-72 - Security requirements for Federal information technology resources.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...' mission. The term “information technology (IT)”, as used in this clause, includes computers, ancillary... Federal information technology resources. 352.239-72 Section 352.239-72 Federal Acquisition Regulations... Provisions and Clauses 352.239-72 Security requirements for Federal information technology resources. As...

  15. 48 CFR 352.239-72 - Security requirements for Federal information technology resources.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...' mission. The term “information technology (IT)”, as used in this clause, includes computers, ancillary... Federal information technology resources. 352.239-72 Section 352.239-72 Federal Acquisition Regulations... Provisions and Clauses 352.239-72 Security requirements for Federal information technology resources. As...

  16. 48 CFR 352.239-72 - Security requirements for Federal information technology resources.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...' mission. The term “information technology (IT)”, as used in this clause, includes computers, ancillary... Federal information technology resources. 352.239-72 Section 352.239-72 Federal Acquisition Regulations... Provisions and Clauses 352.239-72 Security requirements for Federal information technology resources. As...

  17. Reduced Effectiveness of Interruptive Drug-Drug Interaction Alerts after Conversion to a Commercial Electronic Health Record.

    PubMed

    Wright, Adam; Aaron, Skye; Seger, Diane L; Samal, Lipika; Schiff, Gordon D; Bates, David W

    2018-05-15

    Drug-drug interaction (DDI) alerts in electronic health records (EHRs) can help prevent adverse drug events, but such alerts are frequently overridden, raising concerns about their clinical usefulness and contribution to alert fatigue. To study the effect of conversion to a commercial EHR on DDI alert and acceptance rates. Two before-and-after studies. 3277 clinicians who received a DDI alert in the outpatient setting. Introduction of a new, commercial EHR and subsequent adjustment of DDI alerting criteria. Alert burden and proportion of alerts accepted. Overall interruptive DDI alert burden increased by a factor of 6 from the legacy EHR to the commercial EHR. The acceptance rate for the most severe alerts fell from 100 to 8.4%, and from 29.3 to 7.5% for medium severity alerts (P < 0.001). After disabling the least severe alerts, total DDI alert burden fell by 50.5%, and acceptance of Tier 1 alerts rose from 9.1 to 12.7% (P < 0.01). Changing from a highly tailored DDI alerting system to a more general one as part of an EHR conversion decreased acceptance of DDI alerts and increased alert burden on users. The decrease in acceptance rates cannot be fully explained by differences in the clinical knowledge base, nor can it be fully explained by alert fatigue associated with increased alert burden. Instead, workflow factors probably predominate, including timing of alerts in the prescribing process, lack of differentiation of more and less severe alerts, and features of how users interact with alerts.

  18. INITIATE: An Intelligent Adaptive Alert Environment.

    PubMed

    Jafarpour, Borna; Abidi, Samina Raza; Ahmad, Ahmad Marwan; Abidi, Syed Sibte Raza

    2015-01-01

    Exposure to a large volume of alerts generated by medical Alert Generating Systems (AGS) such as drug-drug interaction softwares or clinical decision support systems over-whelms users and causes alert fatigue in them. Some of alert fatigue effects are ignoring crucial alerts and longer response times. A common approach to avoid alert fatigue is to devise mechanisms in AGS to stop them from generating alerts that are deemed irrelevant. In this paper, we present a novel framework called INITIATE: an INtellIgent adapTIve AlerT Environment to avoid alert fatigue by managing alerts generated by one or more AGS. We have identified and categories the lifecycle of different alerts and have developed alert management logic as per the alerts' lifecycle. Our framework incorporates an ontology that represents the alert management strategy and an alert management engine that executes this strategy. Our alert management framework offers the following features: (1) Adaptability based on users' feedback; (2) Personalization and aggregation of messages; and (3) Connection to Electronic Medical Records by implementing a HL7 Clinical Document Architecture parser.

  19. IP telephony based danger alert communication system and its implementation

    NASA Astrophysics Data System (ADS)

    Rezac, Filip; Safarik, Jakub; Voznak, Miroslav; Tomala, Karel; Partila, Pavol

    2013-05-01

    This article discusses a danger alert system created as a part of the research project at Department of Telecommunications of Technical University of Ostrava. The aim of the system is to distribute pre-recorded voice messages in order to alert the called party in danger. This article describes individual technologies, which the application uses for its operation as well as issues relating to hardware requirements and transfer line bandwidth load. The article also describes new algorithms, which had to be developed in order to ensure the reliability of the system. Our intent is focused on disaster management, the message, which should be delivered within specified time span, is typed in the application and text-to-speech module ensures its transformation to a speech format, after that a particular scenario or warned area is selected and a target group is automatically unloaded. For this purpose, we have defined XML format for delivery of phone numbers which are located in the target area and these numbers are obtained from mobile BTS's (Base transmission stations). The benefit of such communication compared to others, is the fact, that it uses a phone call and, therefore, it is possible to get feedback who accepted the message and to improve efficiency of alert system. Finally, the list of unanswered calls is exported and these users can be informed via SMS.

  20. The Schoolhouse Is Raining

    ERIC Educational Resources Information Center

    Yee, Roger

    1974-01-01

    Built into 26 new Chicago school designs are two features: physical plants offering educators latitude to remove nearly all internal partitions for open plan teaching or to return to a traditional "eggorate" format if need be; and a new fire control technology placing a building on electronic alert for immediate reaction to dangerous symptoms with…

  1. The EDUTECH Report, 2002-2003.

    ERIC Educational Resources Information Center

    Warger, Thomas, Ed.

    2003-01-01

    This document consists of 12 issues, an entire volume year, of "The EDUTECH Report." The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two feature articles, a page of news briefs, and a question and answer column. Most issues also contain brief quotations on education…

  2. Transferring new technologies within the federal sector: The New Technology Demonstration Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conover, D.R.; Hunt, D.M.

    1994-08-01

    The federal sector is the largest consumer of products in the United States and annually purchases almost 1.5 quads of energy measured at the building site at a cost of almost $10 billion (U.S. Department of Energy 1991). A review of design, construction, and procurement practices in the federal sector, as well as discussions with manufacturers and vendors, indicated that new technologies are not utilized in as timely a manner as possible. As a consequence of this technology transfer lag, the federal sector loses valuable energy and environmental benefits that can be derived through the application of new technologies. Inmore » addition, opportunities are lost to reduce federal energy expenditures and spur U.S. economic growth through the procurement of such technologies. In 1990, under the direction of the U.S. Department of Energy (DOE) Federal Energy Management Program, the Pacific Northwest Laboratory began the design of a program to accelerate the introduction of new U.S. technologies into the federal sector. Designated first as the Test Bed Demonstration Program and more recently the New Technology Demonstration Program, it sought to shorten the acceptance period of new technologies within the federal sector. By installing and evaluating various new technologies at federal facilities, the Program attempts to increase the acceptance of those new technologies through the results of {open_quotes}real-world{close_quotes} federal installations. Since that time, the Program has conducted new technology demonstrations and evaluations, evolved to address the need for more timely information transfer, and explored collaborative opportunities with other DOE offices and laboratories. This paper explains the processes by which a new technology demonstration project is implemented and presents a general description of the Program results to date.« less

  3. Sleepiness and Safety: Where Biology Needs Technology.

    PubMed

    Abe, Takashi; Mollicone, Daniel; Basner, Mathias; Dinges, David F

    2014-04-01

    Maintaining human alertness and behavioral capability under conditions of sleep loss and circadian misalignment requires fatigue management technologies due to: (1) dynamic nonlinear modulation of performance capability by the interaction of sleep homeostatic drive and circadian regulation; (2) large differences among people in neurobehavioral vulnerability to sleep loss; (3) error in subjective estimates of fatigue on performance; and (4) to inform people of the need for recovery sleep. Two promising areas of technology have emerged for managing fatigue risk in safety-sensitive occupations. The first involves preventing fatigue by optimizing work schedules using biomathematical models of performance changes associated with sleep homeostatic and circadian dynamics. Increasingly these mathematical models account for individual differences to achieve a more accurate estimate of the timing and magnitude of fatigue effects on individuals. The second area involves technologies for detecting transient fatigue from drowsiness. The Psychomotor Vigilance Test (PVT), which has been extensively validated to be sensitive to deficits in attention from sleep loss and circadian misalignment, is an example in this category. Two shorter-duration versions of the PVT recently have been developed for evaluating whether operators have sufficient behavioral alertness prior to or during work. Another example is online tracking the percent of slow eyelid closures (PERCLOS), which has been shown to reflect momentary fluctuations of vigilance. Technologies for predicting and detecting sleepiness/fatigue have the potential to predict and prevent operator errors and accidents in safety-sensitive occupations, as well as physiological and mental diseases due to inadequate sleep and circadian misalignment.

  4. A Near Real-time Decision Support System Improving Forest Management in the Tropics

    NASA Astrophysics Data System (ADS)

    Tabor, K.; Musinsky, J.; Ledezma, J.; Rasolohery, A.; Mendoza, E.; Kistler, H.; Steininger, M.; Morton, D. C.; Melton, F. S.; Manwell, J.; Koenig, K.

    2013-12-01

    Conservation International (CI) has a decade of experience developing near real-time fire and deforestation monitoring and forecasting systems that channel monitoring information from satellite observations directly to national and sub-national government agencies, Non-Government Organizations (NGOs), and local communities. These systems are used to strengthen forest surveillance and monitoring, fire management and prevention, protected areas management and sustainable land use planning. With support from a NASA Wildland Fires grant, in September 2013 CI will launch a brand new near real-time alert system (FIRECAST) to better meet the outstanding needs and challenges users face in addressing ecosystem degradation from wildland fire and illegal forest activities. Outreach efforts and user feedback have indicated the need for seasonal fire forecasts for effective land use planning, faster alert delivery to enhance response to illegal forest activities, and expanded forest monitoring capabilities that enable proactive responses and that strengthen forest conservation and sustainable development actions. The new FIRECAST system addresses these challenges by integrating the current fire alert and deforestation systems and adding improved ecological forecasting of fire risk; expanding data exchange capabilities with mobile technologies; and delivering a deforestation alert product that can inform policies related to land use management and Reduced Emissions from Deforestation and forest Degradation (REDD+). In addition to demonstrating the capabilities of this new real-time alert system, we also highlight how coordination with host-country institutions enhances the system's capacity to address the implementation needs of REDD+ forest carbon projects, improve tropical forest management, strengthen environmental law enforcement, and facilitate the uptake of near real-time satellite monitoring data into business practices of these national/sub-national institutions.

  5. TARGETED TECHNOLOGY TRANSFER TO US INDEPENDENTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Donald F. Duttlinger; E. Lance Cole

    2005-01-01

    The Petroleum Technology Transfer Council (PTTC) continued pursuing its mission of assisting U.S. independent oil and gas producers with timely, informed technology decisions during Fiscal Year 2004 (FY04). PTTC has active grassroots programs through its 10 Regional Lead Organizations (RLOs) and 2 satellite offices. They bring research and academia to the table via their association with geological surveys and engineering departments. The regional directors interact with independent oil and gas producers through technology workshops, resource centers, websites, newsletters, technical publications and other cooperative outreach efforts. PTTC's Headquarters (HQ) staff receives direction from a National Board of Directors predominantly comprised ofmore » American natural gas and oil producers to plan and manage the overall technology transfer program. PTTC HQ implements a comprehensive communications program by interconnecting the talents of the National Board, 10 Regional Producer Advisory Groups (PAG) and the RLOs with industry across the U.S. PTTC effectively combines federal funding through the Department of Energy's (DOE) Office of Fossil Energy, namely the Strategic Center for Natural Gas and Oil with state and industry contributions to share application of upstream technologies. Ultimately, these efforts factor in to provide a safe, secure and reliable energy supply for American consumers. This integrated resource base, combined with industry volunteers guiding PTTC's activities and the dedication of national and regional staff, are achieving notable results regarding domestic production figures. PTTC is increasingly recognized as a critical resource for information and access to technologies by providing direct contact with research, development and demonstration (RD&D) results. A key to the program is demonstrating proven technologies that can be applied broadly and rapidly. This technical progress report summarizes PTTC's accomplishments during FY04. Activities remained at high levels. Board and staff interaction has defined strategic thrusts to further outreach. Networking, involvement in technical activities and an active exhibit schedule are increasing PTTC's sphere of influence with both producers and the service sector. PTTC's reputation for unbiased bottom line information stimulates cooperative ventures with other organizations. Efforts to build the contact database and a growing E-mail Technology Alert service are expanding PTTC's audience.« less

  6. Alert dwell time: introduction of a measure to evaluate interruptive clinical decision support alerts.

    PubMed

    McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras; Hoffman, James M

    2016-04-01

    Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time-the time elapsed from when an interruptive alert is generated to when it is dismissed-could be calculated by using historical alert data from log files. Drug-drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1-4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < 001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < 001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Emergency management response to a warning-level Alaska-source tsunami impacting California: Chapter J in The SAFRR (Science Application for Risk Reduction) Tsunami Scenario

    USGS Publications Warehouse

    Miller, Kevin M.; Long, Kate

    2013-01-01

    This chapter is directed towards two audiences: Firstly, it targets nonemergency management readers, providing them with insight on the process and challenges facing emergency managers in responding to tsunami Warning, particularly given this “short fuse” scenario. It is called “short fuse” because there is only a 5.5-hour window following the earthquake before arrival of the tsunami within which to evaluate the threat, disseminate alert and warning messages, and respond. This action initiates a period when crisis communication is of paramount importance. An additional dynamic that is important to note is that within 15 minutes of the earthquake, the National Oceanic and Atmospheric Administration (NOAA) and the National Weather Service (NWS) will issue alert bulletins for the entire Pacific Coast. This is one-half the time actually presented by recent tsunamis from Japan, Chile, and Samoa. Second, the chapter provides emergency managers at all levels with insights into key considerations they may need to address in order to augment their existing plans and effectively respond to tsunami events. We look at emergency management response to the tsunami threat from three perspectives:“Top Down” (Threat analysis and Alert/Warning information from the Federal agency charged with Alert and Warning) “Bottom Up” (Emergency management’s Incident Command approach to responding to emergencies and disasters based on the needs of impacted local jurisdictions) “Across Time” (From the initiating earthquake event through emergency response) We focus on these questions: What are the government roles, relationships, and products that support Tsunami Alert and Warning dissemination? (Emergency Planning and Preparedness.) What roles, relationships, and products support emergency management response to Tsunami Warning and impact? (Engendering prudent public safety response.) What are the key emergency management activities, considerations, and challenges brought out by the SAFRR tsunami scenario? (Real emergencies) How do these activities, considerations, and challenges play out as the tsunami event unfolds across the “life” of the event? (Lessons)

  8. NREL Solar Cell Wins Federal Technology Transfer Prize | News | NREL

    Science.gov Websites

    Solar Cell Wins Federal Technology Transfer Prize News Release: NREL Solar Cell Wins Federal ) Solar Cell was named a winner of the 2009 Award for Excellence in Technology Transfer by the Federal Laboratory Consortium for Technology Transfer. The original IMM cell was invented by Mark Wanlass of NREL's

  9. An Analysis of the Federal Role in Instructional Technology in the Era of the New Federalism.

    ERIC Educational Resources Information Center

    Scandura, Joseph M.

    This analysis of how the federal government might best promote excellence in education via instructional technology identifies strengths and weaknesses of instructional technology during the 1980's, indicates how technology might aid the teaching and learning process, and suggests how the federal goverment might best assist states and localities…

  10. Definition of common support equipment and space station interface requirements for IOC model technology experiments

    NASA Technical Reports Server (NTRS)

    Russell, Richard A.; Waiss, Richard D.

    1988-01-01

    A study was conducted to identify the common support equipment and Space Station interface requirements for the IOC (initial operating capabilities) model technology experiments. In particular, each principal investigator for the proposed model technology experiment was contacted and visited for technical understanding and support for the generation of the detailed technical backup data required for completion of this study. Based on the data generated, a strong case can be made for a dedicated technology experiment command and control work station consisting of a command keyboard, cathode ray tube, data processing and storage, and an alert/annunciator panel located in the pressurized laboratory.

  11. Hazard alerting and situational awareness in advanced air transport cockpits

    NASA Technical Reports Server (NTRS)

    Hansman, R. John; Wanke, Craig; Kuchar, James; Mykityshyn, Mark; Hahn, Edward; Midkiff, Alan

    1993-01-01

    Advances in avionics and display technology have significantly changed the cockpit environment in current 'glass cockpit' aircraft. Recent developments in display technology, on-board processing, data storage, and datalinked communications are likely to further alter the environment in second and third generation 'glass cockpit' aircraft. The interaction of advanced cockpit technology with human cognitive performance has been a major area of activity within the MIT Aeronautical Systems Laboratory. This paper presents an overview of the MIT Advanced Cockpit Simulation Facility. Several recent research projects are briefly reviewed and the most important results are summarized.

  12. Critical event management with geographic information system technology

    NASA Astrophysics Data System (ADS)

    Booth, John F.; Young, Jeffrey M.

    1997-02-01

    Critical event management at the Los Angeles County Regional Criminal Information Clearinghouse (LACRCIC) provides for the deconfliction of operations, such as reverse stings, arrests, undercover buys/busts, searches, surveillances, and site surveys in the Los Angeles, Orange, Riverside, and San Bernardino county area. During these operations, the opportunity for officer-to-officer confrontation is high, possibly causing a worse case scenario -- officers drawing on each other resulting in friendly fire injuries or casualties. In order to prevent local, state, and federal agencies in the Los Angeles area from experiencing this scenario, the LACRCIC provides around the clock critical event management services via its secure war room. The war room maintains a multicounty detailed street-level map base and geographic information system (GIS) application to support this effort. Operations are telephoned in by the participating agencies and posted in the critical event management system by war room analysts. The application performs both a proximity search around the address and a commonality of suspects search. If a conflict is found, the system alerts the analyst by sounding an audible alarm and flashing the conflicting events on the automated basemap. The analyst then notifies the respective agencies of the conflicting critical events so coordination or rescheduling can occur.

  13. Three Decades of Research on Computer Applications in Health Care

    PubMed Central

    Michael Fitzmaurice, J.; Adams, Karen; Eisenberg, John M.

    2002-01-01

    The Agency for Healthcare Research and Quality and its predecessor organizations—collectively referred to here as AHRQ—have a productive history of funding research and development in the field of medical informatics, with grant investments since 1968 totaling $107 million. Many computerized interventions that are commonplace today, such as drug interaction alerts, had their genesis in early AHRQ initiatives. This review provides a historical perspective on AHRQ investment in medical informatics research. It shows that grants provided by AHRQ resulted in achievements that include advancing automation in the clinical laboratory and radiology, assisting in technology development (computer languages, software, and hardware), evaluating the effectiveness of computer-based medical information systems, facilitating the evolution of computer-aided decision making, promoting computer-initiated quality assurance programs, backing the formation and application of comprehensive data banks, enhancing the management of specific conditions such as HIV infection, and supporting health data coding and standards initiatives. Other federal agencies and private organizations have also supported research in medical informatics, some earlier and to a greater degree than AHRQ. The results and relative roles of these related efforts are beyond the scope of this review. PMID:11861630

  14. Advanced alerting features: displaying new relevant data and retracting alerts.

    PubMed Central

    Kuperman, G. J.; Hiltz, F. L.; Teich, J. M.

    1997-01-01

    We added two advanced features to our automated alerting system. The first feature identifies and displays, at the time an alert is reviewed, relevant data filed between the login time of a specimen leading to an alerting result and the time the alert is reviewed. Relevant data is defined as data of the same kind as generated the alert. The other feature retracts alerts when the alerting value is edited and no longer satisfies the alerting criteria. We evaluated the two features for a 14-week period (new relevant data) and a 6-week period (retraction). Of a total of 1104 alerts in the 14-week evaluation, 286 (25.9%) had new relevant data displayed at alert review time. Of the 286, 75.2% were due to additions of comments to the original piece of alerting data; 24.1% were due to new or pending laboratory results of the same type that generated the alert. Two alerts (out of 490) were retracted in a 6 week period. We conclude that in our system, new clinically relevant data is often added between the time of specimen login and the time that an alerting result from that specimen is reviewed. Retractions occur rarely but are important to detect and communicate. PMID:9357625

  15. The Changing Work Force. Trends and Issues Alerts.

    ERIC Educational Resources Information Center

    Lankard, Bettina A.

    Economic pressures, work force diversity, and advances in technology are changing the nature of work and organizational policy and management. A predicted decline in the annual growth in gross national product is expected to trigger a slowdown in the labor force, especially in occupations that employ workers with only a high school education.…

  16. The Mobile Worker in the Flexible Workplace. Trends and Issues Alert No. 10.

    ERIC Educational Resources Information Center

    Brown, Bettina Lankard

    New information technologies, changing work force demographics, rising customer expectations, transnational companies, and cost pressures are altering traditional views of what constitutes a workplace and have given rise to a new trend: the mobile worker in the flexible workplace. Two factors promote acceptance of telework or telecommuting: (1)…

  17. A Multiple Case Study of Applied Scholastic's Study Technology Program

    ERIC Educational Resources Information Center

    Guidry, Chejuana

    2017-01-01

    In 1966, the Coleman Report alerted the American people to the unfolding tragedy of a dysfunctional educational system. Seventeen years later, the National Commission on Excellence in Education issued its report titled "A Nation At Risk: The Imperative for Educational Reform," on the declining quality of American schools in general. This…

  18. Using Texas Instruments Emulators as Teaching Tools in Quantitative Chemical Analysis

    ERIC Educational Resources Information Center

    Young, Vaneica Y.

    2011-01-01

    This technology report alerts upper-division undergraduate chemistry faculty and lecturers to the use of Texas Instruments emulators as virtual graphing calculators. These may be used in multimedia lectures to instruct students on the use of their graphing calculators to obtain solutions to complex chemical problems. (Contains 1 figure.)

  19. The Changing Adolescent Experience: Societal Trends and the Transition to Adulthood.

    ERIC Educational Resources Information Center

    Mortimer, Jeylan T.; Larson, Reed W.

    The path adolescents take from childhood to adulthood is a product of social, economic, political, and technological forces. These forces may facilitate youths preparation to become healthy adults, or they may leave youth unprepared for adulthood. Knowledgeable projections are vital in shaping the agenda for research; for alerting educators,…

  20. The EDUTECH Report, 1997-1998.

    ERIC Educational Resources Information Center

    EDUTECH Report, 1998

    1998-01-01

    This document consists of 12 issues of the EDUTECH Report. 1998. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two feature articles, a page of news briefs, a preview of the upcoming issue, and a question and answer column. Most issues also contain brief quotations on…

  1. The EDUTECH Report, 1995-96.

    ERIC Educational Resources Information Center

    EDUTECH Report, 1996

    1996-01-01

    This document consists of 12 issues, an entire volume year, of the EDUTECH Report published between April 1995 and March 1996. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue typically contains two feature articles, a page of news briefs, a preview of the upcoming issue, and a…

  2. The EDUTECH Report, 2000-2001.

    ERIC Educational Resources Information Center

    Warger, Thomas, Ed.

    2001-01-01

    This document consists of 12 issues, an entire volume year, of the EDUTECH Report. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two feature articles, a page of news briefs, a preview of the upcoming issue, and a question and answer column. Most issues also contain brief…

  3. The EDUTECH Report, 1998-1999.

    ERIC Educational Resources Information Center

    EDUTECH Report, 1999

    1999-01-01

    This document consists of 12 issues, an entire volume year, of the EDUTECH Report. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two feature articles, a page of news briefs, a preview of the upcoming issue, and a question and answer column. Most issues also contain brief…

  4. The EDUTECH Report, 1996-97.

    ERIC Educational Resources Information Center

    EDUTECH Report, 1996

    1996-01-01

    This document consists of 12 issues, an entire volume year, of the EDUTECH Report published between April 1996 and March 1997. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue typically contains two feature articles, a page of news briefs, a preview of the upcoming issue, and a…

  5. The EDUTECH Report, 1999-2000.

    ERIC Educational Resources Information Center

    EDUTECH Report, 2000

    2000-01-01

    This document consists of the 12 issues, an entire volume year, of the 1999-2000 EDUTECH Report. The newsletter's purpose is to alert faculty and administrators to issues in educational technology. Each issue contains two or three articles, a page of news briefs, a preview of the upcoming issue, and a question and answer column. Most issues also…

  6. Science information systems: Archive, access, and retrieval

    NASA Technical Reports Server (NTRS)

    Campbell, William J.

    1991-01-01

    The objective of this research is to develop technology for the automated characterization and interactive retrieval and visualization of very large, complex scientific data sets. Technologies will be developed for the following specific areas: (1) rapidly archiving data sets; (2) automatically characterizing and labeling data in near real-time; (3) providing users with the ability to browse contents of databases efficiently and effectively; (4) providing users with the ability to access and retrieve system independent data sets electronically; and (5) automatically alerting scientists to anomalies detected in data.

  7. Hypo- and Hyperglycemic Alarms

    PubMed Central

    Howsmon, Daniel; Bequette, B. Wayne

    2015-01-01

    Soon after the discovery that insulin regulates blood glucose by Banting and Best in 1922, the symptoms and risks associated with hypoglycemia became widely recognized. This article reviews devices to warn individuals of impending hypo- and hyperglycemia; biosignals used by these devices include electroencephalography, electrocardiography, skin galvanic resistance, diabetes alert dogs, and continuous glucose monitors (CGMs). While systems based on other technology are increasing in performance and decreasing in size, CGM technology remains the best method for both reactive and predictive alarming of hypo- or hyperglycemia. PMID:25931581

  8. Effect of Traffic Position Accuracy for Conducting Safe Airport Surface Operations

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.; Prinzel, Lawrence J., III; Bailey, Randall E.; Arthur, Jarvis J., III; Barnes, James R.

    2014-01-01

    The Next Generation Air Transportation System (NextGen) concept proposes many revolutionary operational concepts and technologies, such as display of traffic information and movements, airport moving maps (AMM), and proactive alerts of runway incursions and surface traffic conflicts, to deliver an overall increase in system capacity and safety. A piloted simulation study was conducted at the National Aeronautics and Space Administration (NASA) Langley Research Center to evaluate the ability to conduct safe and efficient airport surface operations while utilizing an AMM displaying traffic of various position accuracies as well as the effect of traffic position accuracy on airport conflict detection and resolution (CD&R) capability. Nominal scenarios and off-nominal conflict scenarios were conducted using 12 airline crews operating in a simulated Memphis International Airport terminal environment. The data suggest that all traffic should be shown on the airport moving map, whether qualified or unqualified, and conflict detection and resolution technologies provide significant safety benefits. Despite the presence of traffic information on the map, collisions or near collisions still occurred; when indications or alerts were generated in these same scenarios, the incidences were averted.

  9. 77 FR 30289 - Federal Advisory Committee Act; Technological Advisory Council

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-22

    ... FEDERAL COMMUNICATIONS COMMISSION Federal Advisory Committee Act; Technological Advisory Council... Communications Commission's (FCC) Technological Advisory Council will hold a meeting on Wednesday, June 27, 2012... INFORMATION: The FCC Technological Advisory Council proposed a new work agenda for the [[Page 30290

  10. Clinical Decision Support Alert Appropriateness: A Review and Proposal for Improvement

    PubMed Central

    McCoy, Allison B.; Thomas, Eric J.; Krousel-Wood, Marie; Sittig, Dean F.

    2014-01-01

    Background Many healthcare providers are adopting clinical decision support (CDS) systems to improve patient safety and meet meaningful use requirements. Computerized alerts that prompt clinicians about drug-allergy, drug-drug, and drug-disease warnings or provide dosing guidance are most commonly implemented. Alert overrides, which occur when clinicians do not follow the guidance presented by the alert, can hinder improved patient outcomes. Methods We present a review of CDS alerts and describe a proposal to develop novel methods for evaluating and improving CDS alerts that builds upon traditional informatics approaches. Our proposal incorporates previously described models for predicting alert overrides that utilize retrospective chart review to determine which alerts are clinically relevant and which overrides are justifiable. Results Despite increasing implementations of CDS alerts, detailed evaluations rarely occur because of the extensive labor involved in manual chart reviews to determine alert and response appropriateness. Further, most studies have solely evaluated alert overrides that are appropriate or justifiable. Our proposal expands the use of web-based monitoring tools with an interactive dashboard for evaluating CDS alert and response appropriateness that incorporates the predictive models. The dashboard provides 2 views, an alert detail view and a patient detail view, to provide a full history of alerts and help put the patient's events in context. Conclusion The proposed research introduces several innovations to address the challenges and gaps in alert evaluations. This research can transform alert evaluation processes across healthcare settings, leading to improved CDS, reduced alert fatigue, and increased patient safety. PMID:24940129

  11. A framework for evaluating the appropriateness of clinical decision support alerts and responses

    PubMed Central

    Waitman, Lemuel R; Lewis, Julia B; Wright, Julie A; Choma, David P; Miller, Randolph A; Peterson, Josh F

    2011-01-01

    Objective Alerting systems, a type of clinical decision support, are increasingly prevalent in healthcare, yet few studies have concurrently measured the appropriateness of alerts with provider responses to alerts. Recent reports of suboptimal alert system design and implementation highlight the need for better evaluation to inform future designs. The authors present a comprehensive framework for evaluating the clinical appropriateness of synchronous, interruptive medication safety alerts. Methods Through literature review and iterative testing, metrics were developed that describe successes, justifiable overrides, provider non-adherence, and unintended adverse consequences of clinical decision support alerts. The framework was validated by applying it to a medication alerting system for patients with acute kidney injury (AKI). Results Through expert review, the framework assesses each alert episode for appropriateness of the alert display and the necessity and urgency of a clinical response. Primary outcomes of the framework include the false positive alert rate, alert override rate, provider non-adherence rate, and rate of provider response appropriateness. Application of the framework to evaluate an existing AKI medication alerting system provided a more complete understanding of the process outcomes measured in the AKI medication alerting system. The authors confirmed that previous alerts and provider responses were most often appropriate. Conclusion The new evaluation model offers a potentially effective method for assessing the clinical appropriateness of synchronous interruptive medication alerts prior to evaluating patient outcomes in a comparative trial. More work can determine the generalizability of the framework for use in other settings and other alert types. PMID:21849334

  12. Medication-related clinical decision support alert overrides in inpatients.

    PubMed

    Nanji, Karen C; Seger, Diane L; Slight, Sarah P; Amato, Mary G; Beeler, Patrick E; Her, Qoua L; Dalleur, Olivia; Eguale, Tewodros; Wong, Adrian; Silvers, Elizabeth R; Swerdloff, Michael; Hussain, Salman T; Maniam, Nivethietha; Fiskio, Julie M; Dykes, Patricia C; Bates, David W

    2018-05-01

    To define the types and numbers of inpatient clinical decision support alerts, measure the frequency with which they are overridden, and describe providers' reasons for overriding them and the appropriateness of those reasons. We conducted a cross-sectional study of medication-related clinical decision support alerts over a 3-year period at a 793-bed tertiary-care teaching institution. We measured the rate of alert overrides, the rate of overrides by alert type, the reasons cited for overrides, and the appropriateness of those reasons. Overall, 73.3% of patient allergy, drug-drug interaction, and duplicate drug alerts were overridden, though the rate of overrides varied by alert type (P < .0001). About 60% of overrides were appropriate, and that proportion also varied by alert type (P < .0001). Few overrides of renal- (2.2%) or age-based (26.4%) medication substitutions were appropriate, while most duplicate drug (98%), patient allergy (96.5%), and formulary substitution (82.5%) alerts were appropriate. Despite warnings of potential significant harm, certain categories of alert overrides were inappropriate >75% of the time. The vast majority of duplicate drug, patient allergy, and formulary substitution alerts were appropriate, suggesting that these categories of alerts might be good targets for refinement to reduce alert fatigue. Almost three-quarters of alerts were overridden, and 40% of the overrides were not appropriate. Future research should optimize alert types and frequencies to increase their clinical relevance, reducing alert fatigue so that important alerts are not inappropriately overridden.

  13. Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting

    PubMed Central

    Harrison, Andrew M.; Thongprayoon, Charat; Aakre, Christopher A.; Jeng, Jack Y.; Dziadzko, Mikhail A.; Gajic, Ognjen; Pickering, Brian W.

    2017-01-01

    Background Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. Objective To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. Study Design In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. Results The alert acknowledgement rate from the severe sepsis alert system was 3% (N = 148) and 51% (N = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min (N = 5) and median 2 min (N = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Conclusion Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting. PMID:28316887

  14. Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting.

    PubMed

    Harrison, Andrew M; Thongprayoon, Charat; Aakre, Christopher A; Jeng, Jack Y; Dziadzko, Mikhail A; Gajic, Ognjen; Pickering, Brian W; Herasevich, Vitaly

    2017-01-01

    Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. The alert acknowledgement rate from the severe sepsis alert system was 3% ( N  = 148) and 51% ( N  = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min ( N  = 5) and median 2 min ( N  = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting.

  15. Blending technology and teamwork for successful management of product recalls.

    PubMed

    Frush, Karen; Pleasants, Jane; Shulby, Gail; Hendrix, Barbara; Berson, Brooke; Gordon, Cynthia; Cuffe, Michael S

    2009-12-01

    Patient safety programs have been developed in many hospitals to reduce the risk of harm to patients. Proactive, real-time, and retrospective risk-reduction strategies should be implemented in hospitals, but patient safety leaders should also be cognizant of the risks associated with thousands of products that enter the hospital through the supply chain. A growing number of recalls and alerts related to these products are received by health care facilities each year, through a recall process that is fraught with challenges. Despite the best efforts of health care providers, weaknesses and gaps in the process lead to delays, fragmentation, and disruptions, thus extending the number of days patients may be at risk from potentially faulty or misused products. To address these concerns, Duke Medicine, which comprises an academic medical center, two community hospitals, outlying clinics, physicians' offices, and home health and hospice, implemented a Web-based recall management system. Within three months, the time required to receive, deliver, and close alerts decreased from 43 days to 2.74 days. To maximize the effectiveness of the recall management process, a team of senior Duke Medicine leaders was established to evaluate the impact of product recalls and alerts on patient safety, to evaluate response action plans, and to provide oversight of patient and provider communication strategies. Alerts are now communicated more effectively and responded to in a more consistent and global manner. This comprehensive approach to product recalls is a critical component of a broader Duke Medicine strategy to improve patient safety.

  16. Homeless patients' perceptions about using cell phones to manage medications and attend appointments.

    PubMed

    Moczygemba, Leticia R; Cox, Lauren S; Marks, Samantha A; Robinson, Margaret A; Goode, Jean-Venable R; Jafari, Nellie

    2017-06-01

    The objectives of this study were to (1) describe homeless persons' access and use of cell phones and their perceptions about using cell phone alerts to help manage medications and attend health care appointments and (2) identify demographic characteristics, medication use and appointment history and perceptions associated with interest in receiving cell phone alerts to manage medications and appointments. A cross-sectional survey was conducted in 2013 at a homeless clinic in Virginia. The questionnaire comprised items about cell phone usage, ownership and functions such as text messaging. Participants reported medication use and appointment history, perceptions about cell phone alerts and interest in receiving alerts to manage medications and appointments. Descriptive statistics for all variables are reported. Logistic regression was used to examine predictors of interest in using a cell phone to manage medications and appointments. A total of 290 participants completed the survey; 89% had a cell phone. Seventy-seven percent were interested in appointment reminders, whereas 66%, 60% and 54% were interested in refill reminders, medication taking reminders and medication information messages respectively. Those who believed reminders were helpful were more likely to be interested in medication taking, refill and appointment reminder messages compared to those who did not believe reminders were helpful. A history of running out of medicine and forgetting appointments were predictors of interest in refill and appointment reminders. Mobile technology is a feasible method for communicating medication and appointment information to those experiencing or at risk for homelessness. © 2016 Royal Pharmaceutical Society.

  17. Mobile Traffic Alert and Tourist Route Guidance System Design Using Geospatial Data

    NASA Astrophysics Data System (ADS)

    Bhattacharya, D.; Painho, M.; Mishra, S.; Gupta, A.

    2017-09-01

    The present study describes an integrated system for traffic data collection and alert warning. Geographical information based decision making related to traffic destinations and routes is proposed through the design. The system includes a geospatial database having profile relating to a user of a mobile device. The processing and understanding of scanned maps, other digital data input leads to route guidance. The system includes a server configured to receive traffic information relating to a route and location information relating to the mobile device. Server is configured to send a traffic alert to the mobile device when the traffic information and the location information indicate that the mobile device is traveling toward traffic congestion. Proposed system has geospatial and mobile data sets pertaining to Bangalore city in India. It is envisaged to be helpful for touristic purposes as a route guidance and alert relaying information system to tourists for proximity to sites worth seeing in a city they have entered into. The system is modular in architecture and the novelty lies in integration of different modules carrying different technologies for a complete traffic information system. Generic information processing and delivery system has been tested to be functional and speedy under test geospatial domains. In a restricted prototype model with geo-referenced route data required information has been delivered correctly over sustained trials to designated cell numbers, with average time frame of 27.5 seconds, maximum 50 and minimum 5 seconds. Traffic geo-data set trials testing is underway.

  18. CERN alerter—RSS based system for information broadcast to all CERN offices

    NASA Astrophysics Data System (ADS)

    Otto, R.

    2008-07-01

    Nearly every large organization uses a tool to broadcast messages and information across the internal campus (messages like alerts announcing interruption in services or just information about upcoming events). These tools typically allow administrators (operators) to send 'targeted' messages which are sent only to specific groups of users or computers, e/g only those located in a specified building or connected to a particular computing service. CERN has a long history of such tools: CERNVMS's SPM_quotMESSAGE command, Zephyr [2] and the most recent the NICE Alerter based on the NNTP protocol. The NICE Alerter used on all Windows-based computers had to be phased out as a consequence of phasing out NNTP at CERN. The new solution to broadcast information messages on the CERN campus continues to provide the service based on cross-platform technologies, hence minimizing custom developments and relying on commercial software as much as possible. The new system, called CERN Alerter, is based on RSS (Really Simple Syndication) [9] for the transport protocol and uses Microsoft SharePoint as the backend for database and posting interface. The windows-based client relies on Internet Explorer 7.0 with custom code to trigger the window pop-ups and the notifications for new events. Linux and Mac OS X clients could also rely on any RSS readers to subscribe to targeted notifications. The paper covers the architecture and implementation aspects of the new system.

  19. Physicians’ response to computerised alerts for psychotropic drugs in older persons: a multilevel analysis of the associated alert, patient and physician characteristics

    PubMed Central

    Tamblyn, Robyn; Reidel, Kristen; Patel, Vaishali

    2012-01-01

    Objective Computerised drug alerts are expected to reduce patients’ risk of adverse drug events. However, physicians over-ride most drug alerts, because they believe that the benefit exceeds the risk. The purpose of this study was to determine the drug alert, patient and physician characteristics associated with the: (1) occurrence of psychotropic drug alerts for elderly patients and the (2) response to these alerts by their primary care physicians. Setting Primary care, Quebec, Canada. Design Prospective cohort study. Participants Sixty-one physicians using an electronic prescribing and drug alert decision-support system in their practice, and 3413 elderly patients using psychotropic drugs. Primary and secondary measures Psychotropic drug class, alert severity, patient risk for fall injuries and physician experience, practice volume and computer use were evaluated in relationship to the likelihood of having: (1) a psychotropic drug alert, (2) the prescription revised in response to an alert. Cluster-adjusted alternating logistic regression was used to assess multilevel predictors of alert occurrence and response. Results In total 13 080 psychotropic drug alerts were generated in 8931 visits. Alerts were more likely to be generated for male patients at higher risk of fall-related injury and for physicians who established the highest alert threshold. In 9.9% of alerts seen, the prescription was revised. The highest revision rate was for antipsychotic alerts (22.6%). Physicians were more likely to revise prescriptions for severe alerts (OR 2.03; 95%CI 1.39 to 2.98), if patients had cognitive impairment (OR 1.95; 95%CI 1.13 to 3.36), and if they made more visits to their physician (OR 1.05 per 5 visits; 95%CI 1 to 1.09). Conclusions Physicians view and respond to a small proportion of alerts, mainly for higher-risk patients. To reduce the risk of psychotropic drug-related fall injuries, a new generation of evidence-based drug alerts should be developed. PMID:23024254

  20. Operational Overview for UAS Integration in the NAS Project Flight Test Series 3

    NASA Technical Reports Server (NTRS)

    Valkov, Steffi B.; Sternberg, Daniel; Marston, Michael

    2018-01-01

    The National Aeronautics and Space Administration Unmanned Aircraft Systems Integration in the National Airspace System Project has conducted a series of flight tests intended to support the reduction of barriers that prevent unmanned aircraft from flying without the required waivers from the Federal Aviation Administration. The 2015 Flight Test Series 3, supported two separate test configurations. The first configuration investigated the timing of Detect and Avoid alerting thresholds using a radar equipped unmanned vehicle and multiple live intruders flown at varying encounter geometries.

  1. Differential effects of phasic and tonic alerting on the efficiency of executive attention.

    PubMed

    Asanowicz, Dariusz; Marzecová, Anna

    2017-05-01

    The study examined how alerting and executive attention interact in a task involving conflict resolution. We proposed a tentative scenario in which an initial exogenous phasic alerting phase is followed by an endogenous tonic alerting phase, and hypothesized that these two processes may have distinct effects on conflict resolution. Phasic alerting was expected to increase the conflict, whereas tonic alerting was expected to decrease the conflict. Three experiments were conducted using different variants of the flanker task with visual alerting cues and varied cue-target intervals (SOA), to differentiate between effects of phasic alerting (short SOA) and tonic alerting (long SOA). The results showed that phasic alerting consistently decreased the efficiency of conflict resolution indexed by response time and accuracy, whereas tonic alerting increased the accuracy of conflict resolution, but at a cost in the speed of processing the conflict. The third experiment additionally showed that the effects of phasic alerting may be modulated by the psychophysical strength of alerting cues. Discussed are possible mechanisms that could account for the observed interactions between alerting and conflict resolution, as well as some discrepancies between the current and previous studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. 48 CFR 27.204 - Patented technology under trade agreements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Patented technology under trade agreements. 27.204 Section 27.204 Federal Acquisition Regulations System FEDERAL ACQUISITION... Patented technology under trade agreements. ...

  3. 48 CFR 27.204 - Patented technology under trade agreements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Patented technology under trade agreements. 27.204 Section 27.204 Federal Acquisition Regulations System FEDERAL ACQUISITION... Patented technology under trade agreements. ...

  4. 48 CFR 27.204 - Patented technology under trade agreements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Patented technology under trade agreements. 27.204 Section 27.204 Federal Acquisition Regulations System FEDERAL ACQUISITION... Patented technology under trade agreements. ...

  5. 48 CFR 27.204 - Patented technology under trade agreements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Patented technology under trade agreements. 27.204 Section 27.204 Federal Acquisition Regulations System FEDERAL ACQUISITION... Patented technology under trade agreements. ...

  6. 48 CFR 27.204 - Patented technology under trade agreements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Patented technology under trade agreements. 27.204 Section 27.204 Federal Acquisition Regulations System FEDERAL ACQUISITION... Patented technology under trade agreements. ...

  7. Optimizing the real-time ground level enhancement alert system based on neutron monitor measurements: Introducing GLE Alert Plus

    NASA Astrophysics Data System (ADS)

    Souvatzoglou, G.; Papaioannou, A.; Mavromichalaki, H.; Dimitroulakos, J.; Sarlanis, C.

    2014-11-01

    Whenever a significant intensity increase is being recorded by at least three neutron monitor stations in real-time mode, a ground level enhancement (GLE) event is marked and an automated alert is issued. Although, the physical concept of the algorithm is solid and has efficiently worked in a number of cases, the availability of real-time data is still an open issue and makes timely GLE alerts quite challenging. In this work we present the optimization of the GLE alert that has been set into operation since 2006 at the Athens Neutron Monitor Station. This upgrade has led to GLE Alert Plus, which is currently based upon the Neutron Monitor Database (NMDB). We have determined the critical values per station allowing us to issue reliable GLE alerts close to the initiation of the event while at the same time we keep the false alert rate at low levels. Furthermore, we have managed to treat the problem of data availability, introducing the Go-Back-N algorithm. A total of 13 GLE events have been marked from January 2000 to December 2012. GLE Alert Plus issued an alert for 12 events. These alert times are compared to the alert times of GOES Space Weather Prediction Center and Solar Energetic Particle forecaster of the University of Málaga (UMASEP). In all cases GLE Alert Plus precedes the GOES alert by ≈8-52 min. The comparison with UMASEP demonstrated a remarkably good agreement. Real-time GLE alerts by GLE Alert Plus may be retrieved by http://cosray.phys.uoa.gr/gle_alert_plus.html, http://www.nmdb.eu, and http://swe.ssa.esa.int/web/guest/space-radiation. An automated GLE alert email notification system is also available to interested users.

  8. Evaluation of health alerts from an early illness warning system in independent living.

    PubMed

    Rantz, Marilyn J; Scott, Susan D; Miller, Steven J; Skubic, Marjorie; Phillips, Lorraine; Alexander, Greg; Koopman, Richelle J; Musterman, Katy; Back, Jessica

    2013-06-01

    Passive sensor networks were deployed in independent living apartments to monitor older adults in their home environments to detect signs of impending illness and alert clinicians so they can intervene and prevent or delay significant changes in health or functional status. A retrospective qualitative deductive content analysis was undertaken to refine health alerts to improve clinical relevance to clinicians as they use alerts in their normal workflow of routine care delivery to older adults. Clinicians completed written free-text boxes to describe actions taken (or not) as a result of each alert; they also rated the clinical significance (relevance) of each health alert on a scale of 1 to 5. Two samples of the clinician's written responses to the health alerts were analyzed after alert algorithms had been adjusted based on results of a pilot study using health alerts to enhance clinical decision-making. In the first sample, a total of 663 comments were generated by seven clinicians in response to 385 unique alerts; there are more comments than alerts because more than one clinician rated the same alert. The second sample had a total of 142 comments produced by three clinicians in response to 88 distinct alerts. The overall clinical relevance of the alerts, as judged by the content of the qualitative comments by clinicians for each alert, improved from 33.3% of the alerts in the first sample classified as clinically relevant to 43.2% in the second. The goal is to produce clinically relevant alerts that clinicians find useful in daily practice. The evaluation methods used are described to assist others as they consider building and iteratively refining health alerts to enhance clinical decision making.

  9. An IDS Alerts Aggregation Algorithm Based on Rough Set Theory

    NASA Astrophysics Data System (ADS)

    Zhang, Ru; Guo, Tao; Liu, Jianyi

    2018-03-01

    Within a system in which has been deployed several IDS, a great number of alerts can be triggered by a single security event, making real alerts harder to be found. To deal with redundant alerts, we propose a scheme based on rough set theory. In combination with basic concepts in rough set theory, the importance of attributes in alerts was calculated firstly. With the result of attributes importance, we could compute the similarity of two alerts, which will be compared with a pre-defined threshold to determine whether these two alerts can be aggregated or not. Also, time interval should be taken into consideration. Allowed time interval for different types of alerts is computed individually, since different types of alerts may have different time gap between two alerts. In the end of this paper, we apply proposed scheme on DAPRA98 dataset and the results of experiment show that our scheme can efficiently reduce the redundancy of alerts so that administrators of security system could avoid wasting time on useless alerts.

  10. Alertness and cognitive control: Toward a spatial grouping hypothesis.

    PubMed

    Schneider, Darryl W

    2018-05-01

    A puzzling interaction involving alertness and cognitive control is indicated by the finding of faster performance but larger congruency effects on alert trials (on which alerting cues are presented before the task stimuli) than on no-alert trials in selective attention tasks. In the present study, the author conducted four experiments to test hypotheses about the interaction. Manipulation of stimulus spacing revealed a difference in congruency effects between alert and no-alert trials for narrowly spaced stimuli but not for widely spaced stimuli, inconsistent with the hypothesis that increased alertness is associated with more diffuse attention. Manipulation of color grouping revealed similar differences in congruency effects between alert and no-alert trials for same-color and different-color groupings of targets and distractors, inconsistent with the general hypothesis that increased alertness is associated with more perceptual grouping. To explain the results, the author proposes that increased alertness is associated specifically with more spatial grouping of stimuli, possibly by modulating the threshold for parsing stimulus displays into distinct objects.

  11. Managing the Alert Process at NewYork-Presbyterian Hospital

    PubMed Central

    Kuperman, Gilad J; Diamente, Rosanna; Khatu, Vrinda; Chan-Kraushar, Terri; Stetson, Pete; Boyer, Aurelia; Cooper, Mary

    2005-01-01

    Clinical decision support can improve the quality of care, but requires substantial knowledge management activities. At NewYork-Presbyterian Hospital in New York City, we have implemented a formal alert management process whereby only hospital committees and departments can request alerts. An explicit requestor, who will help resolve the details of the alert logic and the alert message must be identified. Alerts must be requested in writing using a structured alert request form. Alert requests are reviewed by the Alert Committee and then forwarded to the Information Systems department for a software development estimate. The model required that clinical committees and departments become more actively involved in the development of alerts than had previously been necessary. In the 12 months following implementation, 10 alert requests were received. The model has been well received. A lot of the knowledge engineering work has been distributed and burden has been removed from scarce medical informatics resources. PMID:16779073

  12. Optimizing drug-dose alerts using commercial software throughout an integrated health care system.

    PubMed

    Saiyed, Salim M; Greco, Peter J; Fernandes, Glenn; Kaelber, David C

    2017-11-01

    All default electronic health record and drug reference database vendor drug-dose alerting recommendations (single dose, daily dose, dose frequency, and dose duration) were silently turned on in inpatient, outpatient, and emergency department areas for pediatric-only and nonpediatric-only populations. Drug-dose alerts were evaluated during a 3-month period. Drug-dose alerts fired on 12% of orders (104 098/834 911). System-level and drug-specific strategies to decrease drug-dose alerts were analyzed. System-level strategies included: (1) turning off all minimum drug-dosing alerts, (2) turning off all incomplete information drug-dosing alerts, (3) increasing the maximum single-dose drug-dose alert threshold to 125%, (4) increasing the daily dose maximum drug-dose alert threshold to 125%, and (5) increasing the dose frequency drug-dose alert threshold to more than 2 doses per day above initial threshold. Drug-specific strategies included changing drug-specific maximum single and maximum daily drug-dose alerting parameters for the top 22 drug categories by alert frequency. System-level approaches decreased alerting to 5% (46 988/834 911) and drug-specific approaches decreased alerts to 3% (25 455/834 911). Drug-dose alerts varied between care settings and patient populations. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Event-Driven Technology to Generate Relevant Collections of Near-Realtime Data

    NASA Astrophysics Data System (ADS)

    Graves, S. J.; Keiser, K.; Nair, U. S.; Beck, J. M.; Ebersole, S.

    2017-12-01

    Getting the right data when it is needed continues to be a challenge for researchers and decision makers. Event-Driven Data Delivery (ED3), funded by the NASA Applied Science program, is a technology that allows researchers and decision makers to pre-plan what data, information and processes they need to have collected or executed in response to future events. The Information Technology and Systems Center at the University of Alabama in Huntsville (UAH) has developed the ED3 framework in collaboration with atmospheric scientists at UAH, scientists at the Geological Survey of Alabama, and other federal, state and local stakeholders to meet the data preparedness needs for research, decisions and situational awareness. The ED3 framework supports an API that supports the addition of loosely-coupled, distributed event handlers and data processes. This approach allows the easy addition of new events and data processes so the system can scale to support virtually any type of event or data process. Using ED3's underlying services, applications have been developed that monitor for alerts of registered event types and automatically triggers subscriptions that match new events, providing users with a living "album" of results that can continued to be curated as more information for an event becomes available. This capability can allow users to improve capacity for the collection, creation and use of data and real-time processes (data access, model execution, product generation, sensor tasking, social media filtering, etc), in response to disaster (and other) events by preparing in advance for data and information needs for future events. This presentation will provide an update on the ED3 developments and deployments, and further explain the applicability for utilizing near-realtime data in hazards research, response and situational awareness.

  14. Advanced text and video analytics for proactive decision making

    NASA Astrophysics Data System (ADS)

    Bowman, Elizabeth K.; Turek, Matt; Tunison, Paul; Porter, Reed; Thomas, Steve; Gintautas, Vadas; Shargo, Peter; Lin, Jessica; Li, Qingzhe; Gao, Yifeng; Li, Xiaosheng; Mittu, Ranjeev; Rosé, Carolyn Penstein; Maki, Keith; Bogart, Chris; Choudhari, Samrihdi Shree

    2017-05-01

    Today's warfighters operate in a highly dynamic and uncertain world, and face many competing demands. Asymmetric warfare and the new focus on small, agile forces has altered the framework by which time critical information is digested and acted upon by decision makers. Finding and integrating decision-relevant information is increasingly difficult in data-dense environments. In this new information environment, agile data algorithms, machine learning software, and threat alert mechanisms must be developed to automatically create alerts and drive quick response. Yet these advanced technologies must be balanced with awareness of the underlying context to accurately interpret machine-processed indicators and warnings and recommendations. One promising approach to this challenge brings together information retrieval strategies from text, video, and imagery. In this paper, we describe a technology demonstration that represents two years of tri-service research seeking to meld text and video for enhanced content awareness. The demonstration used multisource data to find an intelligence solution to a problem using a common dataset. Three technology highlights from this effort include 1) Incorporation of external sources of context into imagery normalcy modeling and anomaly detection capabilities, 2) Automated discovery and monitoring of targeted users from social media text, regardless of language, and 3) The concurrent use of text and imagery to characterize behaviour using the concept of kinematic and text motifs to detect novel and anomalous patterns. Our demonstration provided a technology baseline for exploiting heterogeneous data sources to deliver timely and accurate synopses of data that contribute to a dynamic and comprehensive worldview.

  15. U.S. EPA Federal Technology Transfer Program Fact Sheet

    EPA Pesticide Factsheets

    The Federal Technology Transfer Act (FTTA), enacted by Congress in 1986 and building on previous legislation, improves access to federal laboratories by non-federal organizations for research and development opportunities.

  16. A systematic review of the effectiveness of interruptive medication prescribing alerts in hospital CPOE systems to change prescriber behavior and improve patient safety.

    PubMed

    Page, N; Baysari, M T; Westbrook, J I

    2017-09-01

    To assess the evidence of the effectiveness of different categories of interruptive medication prescribing alerts to change prescriber behavior and/or improve patient outcomes in hospital computerized provider order entry (CPOE) systems. PubMed, Embase, CINAHL and the Cochrane Library were searched for relevant articles published between January 2000 and February 2016. Studies were included if they compared the outcomes of automatic, interruptive medication prescribing alert/s to a control/comparison group to determine alert effectiveness. Twenty-three studies describing 32 alerts classified into 11 alert categories were identified. The most common alert categories studied were drug-condition interaction (n=6), drug-drug interaction alerts (n=6) and corollary order alerts (n=6). All 23 papers investigated the effect of the intervention alert on at least one outcome measure of prescriber behavior. Just over half of the studies (53%, n=17) reported a statistically significant beneficial effect from the intervention alert; 34% (n=11) reported no statistically significant effect, and 6% (n=2) reported a significant detrimental effect. Two studies also evaluated the effect of alerts on patient outcome measures; neither finding that patient outcomes significantly improved following alert implementation (6%, n=2). The greatest volume of evidence relates to three alert categories: drug-condition, drug-drug and corollary order alerts. Of these, drug-condition alerts had the greatest number of studies reporting positive effects (five out of six studies). Only two of six studies of drug-drug interaction and one of six of corollary alerts reported positive benefits. The current evidence-base does not show a clear indication that particular categories of alerts are more effective than others. While the majority of alert categories were shown to improve outcomes in some studies, there were also many cases where outcomes did not improve. This lack of evidence hinders decisions about the amount and type of decision support that should be integrated into CPOE systems to increase safety while reducing the risk of alert fatigue. Virtually no studies have sought to investigate the impact on changes to prescriber behavior and outcomes overall when alerts from multiple categories are incorporated within the same system. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Defining the Collision Avoidance Region for DAA Systems

    NASA Technical Reports Server (NTRS)

    Thipphavong, David; Cone, Andrew; Park, Chunki; Lee, Seung Man; Santiago, Confesor

    2016-01-01

    Unmanned aircraft systems (UAS) will be required to equip with a detect-­-and-­-avoid (DAA) system in order to satisfy the federal aviation regulations to maintain well clear of other aircraft, some of which may be equipped with a Traffic Collision Avoidance System (TCAS) to mitigate the possibility of mid-­-air collisions. As such, the minimum operational performance standards (MOPS) for UAS DAA systems are being designed with TCAS interoperability in mind by a group of industry, government, and academic institutions named RTCA Special Committee-228 (SC-228). This document will discuss the development of the spatial-­-temporal volume known as the collision avoidance region in which the DAA system is not allowed to provide vertical guidance to maintain or regain DAA well clear that could conflict with resolution advisories (RAs) issued by the intruder aircraft's TCAS system. Three collision avoidance region definition candidates were developed based on the existing TCAS RA and DAA alerting definitions. They were evaluated against each other in terms of their interoperability with TCAS RAs and DAA alerts in an unmitigated factorial encounter analysis of 1.3 million simulated pairs.

  18. Prescription order risk factors for pediatric dosing alerts.

    PubMed

    Stultz, J S; Porter, K; Nahata, M C

    2015-02-01

    To determine dosing alert rates based on prescription order characteristics and identify prescription order risk factors for the occurrence of dosing alerts. A retrospective analysis of inpatient medication orders and dosing alerts occurring during October 2011 and January, April, and July 2012 at a pediatric institution. Prescription orders and alerts were categorized by: medication class, patient age, route of administration, and month of the year. There were 228,259 orders during the studied period, with 11,072 alerted orders (4.9%). The most frequently alerted medication class was the non-analgesic central nervous system agent class (14% of alerts). Age, route, medication class, and month all independently affected dosing alert rates. The alert rate was highest for immunosuppressive agents (54%), neonates (6.7%), and orders for rectal administration (9.5%). The alert rate was higher in adult patients receiving their care at a pediatric institution (5.7%) compared to children (4.7%), but after multivariate analysis, pediatric orders had higher odds for an alert (OR 1.1, 95% CI 1.05-1.16). Mercaptopurine had the highest alert rate when categorized by active ingredient (73.9%). Albuterol 2.5mg/mL continuous aerosol and heparin 1000 units in 0.9% sodium chloride injection solution were the unique medications with the highest alert rates (100.0% and 97.7%, respectively). Certain types of prescription orders have a higher risk for causing dosing alerts than others. Patient age, medication class, route of administration, and the month of year can affect dosing alert rates. Design and customization efforts should focus on these medications and prescription order characteristics that increase the risk for dosing alerts. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Factors influencing alert acceptance: a novel approach for predicting the success of clinical decision support

    PubMed Central

    Seidling, Hanna M; Phansalkar, Shobha; Seger, Diane L; Paterno, Marilyn D; Shaykevich, Shimon; Haefeli, Walter E

    2011-01-01

    Background Clinical decision support systems can prevent knowledge-based prescription errors and improve patient outcomes. The clinical effectiveness of these systems, however, is substantially limited by poor user acceptance of presented warnings. To enhance alert acceptance it may be useful to quantify the impact of potential modulators of acceptance. Methods We built a logistic regression model to predict alert acceptance of drug–drug interaction (DDI) alerts in three different settings. Ten variables from the clinical and human factors literature were evaluated as potential modulators of provider alert acceptance. ORs were calculated for the impact of knowledge quality, alert display, textual information, prioritization, setting, patient age, dose-dependent toxicity, alert frequency, alert level, and required acknowledgment on acceptance of the DDI alert. Results 50 788 DDI alerts were analyzed. Providers accepted only 1.4% of non-interruptive alerts. For interruptive alerts, user acceptance positively correlated with frequency of the alert (OR 1.30, 95% CI 1.23 to 1.38), quality of display (4.75, 3.87 to 5.84), and alert level (1.74, 1.63 to 1.86). Alert acceptance was higher in inpatients (2.63, 2.32 to 2.97) and for drugs with dose-dependent toxicity (1.13, 1.07 to 1.21). The textual information influenced the mode of reaction and providers were more likely to modify the prescription if the message contained detailed advice on how to manage the DDI. Conclusion We evaluated potential modulators of alert acceptance by assessing content and human factors issues, and quantified the impact of a number of specific factors which influence alert acceptance. This information may help improve clinical decision support systems design. PMID:21571746

  20. Community Alert: Using Text Messaging and Social Media to Improve Campus Emergency Planning

    ERIC Educational Resources Information Center

    Connolly, Maureen

    2014-01-01

    This article describes emergency management and the part that social media technologies and mobile messaging have made when they are included as part of the campus emergency plan. Administrators have found that ample notification and preparedness must be built into campus communication systems. Social media platforms such as Twitter and Facebook…

  1. 76 FR 37796 - Notice of Availability of Government-Owned Inventions; Available for Licensing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-28

    ... Aircraft Division, Business and Partnership Office, Office of Research and Technology Applications... October 26, 2010 U.S. Patent Application No. 7,839,304 B2: Method and System for Alerting Aircrew to... Application No. 12/868,772: Colorimetric Method for Detection of Biodiesel in Fuel, Navy Case No. PAX37, filed...

  2. Early Alert of Academically At-Risk Students: An Open Source Analytics Initiative

    ERIC Educational Resources Information Center

    Jayaprakash, Sandeep M.; Moody, Erik W.; Lauría, Eitel J. M.; Regan, James R.; Baron, Joshua D.

    2014-01-01

    The Open Academic Analytics Initiative (OAAI) is a collaborative, multi-year grant program aimed at researching issues related to the scaling up of learning analytics technologies and solutions across all of higher education. The paper describes the goals and objectives of the OAAI, depicts the process and challenges of collecting, organizing and…

  3. On the Horizon. The Environmental Scanning Newsletter for Leaders in Higher Education, 1992-1993.

    ERIC Educational Resources Information Center

    Morrison, James L., Ed.

    1993-01-01

    This document consists of the preview issue and first five issues of a new newsletter designed to alert members of the higher education community to driving forces and potential developments in the macroenvironment that constitute threats or opportunities to colleges and universities. It reports news from the social, technological, economic,…

  4. The Web: Creating and Changing Jobs. Trends and Issues Alerts.

    ERIC Educational Resources Information Center

    Brown, Bettina Lankard

    The World Wide Web is changing not only how individuals locate jobs but also the ways existing jobs are performed. Individuals seeking work will need to know how to use the Web as a tool for enhancing their job performance. The enhanced global communication made possible through Internet technology and the increase of marketing plans combining…

  5. ACCESSING FEDERAL DATA BASES FOR CONTAMINATED SITE CLEAN-UP TECHNOLOGIES

    EPA Science Inventory

    The Federal Remediation Technologies Roundtable (Roundtable) eveloped this publication to provide information on accessing Federal data bases that contain data on innovative remediation technologies. The Roundtable includes representatives from the Department of Defense (DoD), En...

  6. Optimization of drug-drug interaction alert rules in a pediatric hospital's electronic health record system using a visual analytics dashboard.

    PubMed

    Simpao, Allan F; Ahumada, Luis M; Desai, Bimal R; Bonafide, Christopher P; Gálvez, Jorge A; Rehman, Mohamed A; Jawad, Abbas F; Palma, Krisha L; Shelov, Eric D

    2015-03-01

    To develop and evaluate an electronic dashboard of hospital-wide electronic health record medication alerts for an alert fatigue reduction quality improvement project. We used visual analytics software to develop the dashboard. We collaborated with the hospital-wide Clinical Decision Support committee to perform three interventions successively deactivating clinically irrelevant drug-drug interaction (DDI) alert rules. We analyzed the impact of the interventions on care providers' and pharmacists' alert and override rates using an interrupted time series framework with piecewise regression. We evaluated 2 391 880 medication alerts between January 31, 2011 and January 26, 2014. For pharmacists, the median alert rate prior to the first DDI deactivation was 58.74 alerts/100 orders (IQR 54.98-60.48) and 25.11 alerts/100 orders (IQR 23.45-26.57) following the three interventions (p<0.001). For providers, baseline median alert rate prior to the first round of DDI deactivation was 19.73 alerts/100 orders (IQR 18.66-20.24) and 15.11 alerts/100 orders (IQR 14.44-15.49) following the three interventions (p<0.001). In a subgroup analysis, we observed a decrease in pharmacists' override rates for DDI alerts that were not modified in the system from a median of 93.06 overrides/100 alerts (IQR 91.96-94.33) to 85.68 overrides/100 alerts (IQR 84.29-87.15, p<0.001). The medication serious safety event rate decreased during the study period, and there were no serious safety events reported in association with the deactivated alert rules. An alert dashboard facilitated safe rapid-cycle reductions in alert burden that were temporally associated with lower pharmacist override rates in a subgroup of DDIs not directly affected by the interventions; meanwhile, the pharmacists' frequency of selecting the 'cancel' option increased. We hypothesize that reducing the alert burden enabled pharmacists to devote more attention to clinically relevant alerts. © The Author 2014. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Provider management strategies of abnormal test result alerts: a cognitive task analysis.

    PubMed

    Hysong, Sylvia J; Sawhney, Mona K; Wilson, Lindsay; Sittig, Dean F; Espadas, Donna; Davis, Traber; Singh, Hardeep

    2010-01-01

    Electronic medical records (EMRs) facilitate abnormal test result communication through "alert" notifications. The aim was to evaluate how primary care providers (PCPs) manage alerts related to critical diagnostic test results on their EMR screens, and compare alert-management strategies of providers with high versus low rates of timely follow-up of results. 28 PCPs from a large, tertiary care Veterans Affairs Medical Center (VAMC) were purposively sampled according to their rates of timely follow-up of alerts, determined in a previous study. Using techniques from cognitive task analysis, participants were interviewed about how and when they manage alerts, focusing on four alert-management features to filter, sort and reduce unnecessary alerts on their EMR screens. Provider knowledge of alert-management features ranged between 4% and 75%. Almost half (46%) of providers did not use any of these features, and none used more than two. Providers with higher versus lower rates of timely follow-up used the four features similarly, except one (customizing alert notifications). Providers with low rates of timely follow-up tended to manually scan the alert list and process alerts heuristically using their clinical judgment. Additionally, 46% of providers used at least one workaround strategy to manage alerts. Considerable heterogeneity exists in provider use of alert-management strategies; specific strategies may be associated with lower rates of timely follow-up. Standardization of alert-management strategies including improving provider knowledge of appropriate tools in the EMR to manage alerts could reduce the lack of timely follow-up of abnormal diagnostic test results.

  8. Lessons for tsunami risk mitigation from recent events occured in Chile: research findings for alerting and evacuation from interdisciplinary perspectives

    NASA Astrophysics Data System (ADS)

    Cienfuegos, R.; Catalan, P. A.; Leon, J.; Gonzalez, G.; Repetto, P.; Urrutia, A.; Tomita, T.; Orellana, V.

    2016-12-01

    In the wake of the 2010 tsunami that hit Chile, a major public effort to promote interdisciplinary disaster reseach was undertaken by the Comisión Nacional de Investigación Científica y Tecnológica (Conicyt) allocating funds to create the Center for Integrated Research on Natural Risks Management (CIGIDEN). This effort has been key in promoting associativity between national and international research teams in order to transform the frequent occurrence of extreme events that affect Chile into an opportunity for interdisciplinary research. In this presentation we will summarize some of the fundamental research findings regarding tsunami forecasting, alerting, and evacuation processes based on interdisciplinary field work campaigns and modeling efforts conducted in the wake of the three most recent destructive events that hit Chile in 2010, 2014, and 2015. One of the main results that we shall emphatize from these findings, is that while research and operational efforts to model and forecast tsunamis are important, technological positivisms should not undermine educational efforts that have proved to be effective in reducing casualties due to tsunamis in the near field. Indeed, in recent events that hit Chile, first tsunami waves reached the adjacent generation zones in time scales comparable with the required time for data gathering and modeling even for the most sophisticated early warning tsunami algorithms currently available. The latter emphasizes self-evacuation from coastal areas, while forecasting and monitoring tsunami hazards remain very important for alerting more distant areas, and are essential for alert cancelling especially when shelf and embayment resonance, and edge wave propagation may produce destructive late tsunami arrivals several hours after the nucleation of the earthquake. By combining some of the recent evidence we have gathered in Chile on seismic source uncertainities (both epistemic and aleatoric), tsunami hydrodynamics, the response of official national institutions in charge of emergency management, and the evacuation processess observed, we will attempt to bring some elements for discussing on the complex balance between technological positivism and risk awareness and education programs that may help prioritizing funding efforts in tsunami prone regions.

  9. The NAS Alert System: A look at the first eight years

    USGS Publications Warehouse

    Fuller, Pamela L.; Neilson, Matt; Huge, Dane H.

    2013-01-01

    The U.S. Geological Survey's Nonindigenous Aquatic Species (NAS) database program (http://nas.er.usgs.gov) tracks the distribution of introduced aquatic organisms across the United States. Awareness of, and timely response to, novel species introductions by those involved in nonindigenous aquatic species management and research requires a framework for rapid dissemination of occurrence data as it is incorporated into the NAS database. In May 2004, the NAS program developed an alert system to notify registered users of new introductions as part of a national early detection/rapid response system. This article summarizes information on system users and dispatched alerts from the system's inception through the end of 2011. The NAS alert system has registered over 1,700 users, with approximately 800 current subscribers. A total of 1,189 alerts had been transmitted through 2011. More alerts were sent for Florida (134 alerts) than for any other state. Fishes comprise the largest taxonomic group of alerts (440), with mollusks, plants, and crustaceans each containing over 100 alerts. Most alerts were for organisms that were intentionally released (414 alerts), with shipping, escape from captivity, and hitchhiking also representing major vectors. To explore the archive of sent alerts and to register, the search and signup page for the alert system can be found online at http://nas.er.usgs.gov/AlertSystem/default.aspx.

  10. The Impact of the Photocopier on Peer Review and Nursing Theory.

    PubMed

    Nicoll, Leslie H

    Two influential publications in nursing, Nursing Research and Perspectives on Nursing Theory, are used to illustrate how a specific technology change-the invention and marketing of the photocopier-influenced knowledge dissemination and information utilization in nursing, perhaps in ways not immediately apparent. Content analysis and historical comparison, using editorials from Nursing Research, historical reports on technology development, and personal reflections on the genesis of Perspectives on Nursing Theory are used to create an argument for the role of technology in peer review, information utilization, and knowledge development in nursing. Multiple forces influence nursing science. Scholars should be alert to data inputs from many sources and respond accordingly.

  11. Emerging Technologies: Web 2.0.

    PubMed

    Holt, Claire

    2011-03-01

    Web 2.0 has brought a change to how we communicate and disseminate information with the use of Twitter, Facebook, YouTube, instant messaging and blogging. This technology is beginning to be used in the health field for public awareness campaigns, emergency health alerts, medical education and remote healthcare services. Australian Health Information Managers will be called upon to reconcile their organisations' policies and procedures regarding the use of Web 2.0 technologies within the existing legal framework of privacy, confidentiality and consent. This article explores various applications of Web 2.0, their benefits and some of their potential legal and ethical implications when implemented in Australia.

  12. Study of Federal technology transfer activities in areas of interest to NASA Office of Space and Terrestrial Applications

    NASA Technical Reports Server (NTRS)

    Madigan, J. A.; Earhart, R. W.

    1978-01-01

    Forty-three ongoing technology transfer programs in Federal agencies other than NASA were selected from over 200 current Federal technology transfer activities. Selection was made and specific technology transfer mechanisms utilized. Detailed information was obtained on the selected programs by reviewing published literature, and conducting telephone interviews with each program manager. Specific information collected on each program includes technology areas; user groups, mechanisms employed, duration of program, and level of effort. Twenty-four distinct mechanisms are currently employed in Federal technology transfer activities totaling $260 million per year. Typical applications of each mechanism were reviewed, and caveats on evaluating program effectiveness were discussed. A review of recent federally funded research in technology transfer to state and local governments was made utilizing the Smithsonian Science Information Exchange, and abstracts of interest to NASA were selected for further reference.

  13. Horizon scanning of new and emerging medical technology in Australia: its relevance to Medical Services Advisory Committee health technology assessments and public funding.

    PubMed

    O'Malley, Sue P; Jordan, Ernest

    2009-07-01

    In 1998, a formal process using full health technology assessments (HTAs) was implemented to determine the suitability for public subsidy of new and emerging medical technologies in the Australian private healthcare sector. This process is overseen by the Medical Services Advisory Committee (MSAC). In 2004, horizon scanning was introduced in Australia with the stated objective of identifying new and emerging medical technologies into the public healthcare sector, with consideration to the publicly subsidized private healthcare sector. How well horizon scanning works in identifying new and emerging technologies suitable for government subsidized funding in the private healthcare sector is examined in this study. A descriptive evaluation of the impact of horizon scanning as an early alert and awareness system identifying new and emerging technologies before these technologies are submitted to MSAC for a full HTA. All MSAC HTAs commenced after the introduction of horizon scanning in 2004 were cross-checked with the list of Prioritizing Summaries or Horizon Scanning Reports to determine whether a prior Prioritizing Summary or Horizon Scanning Report had been carried out. Of the forty-three technologies that were the subject of a full MSAC HTAs in the time period examined, only eleven had been the subject of either a Prioritizing Summary or Horizon Scanning Report. As a result of a full MSAC HTA, twelve of the technologies that were not the subject of a Prioritizing Summary or Horizon Scanning Report were given positive recommendations for public funding. Horizon scanning was set up to scan the introduction of new and emerging medical technologies into the public healthcare sector, with consideration to the publicly subsidized private healthcare sector. Based on the number of new and emerging technologies that have been the subject of a full MSAC HTA without first being subjected to either a Prioritizing Summary or Horizon Scanning Report, horizon scanning in Australia does not function as an "early alert and awareness system" for funding in the publicly subsidized private healthcare sector in Australia.

  14. Federal Technology Transfer Act Success Stories

    EPA Pesticide Factsheets

    Successful Federal Technology Transfer Act (FTTA) partnerships demonstrate the many advantages of technology transfer and collaboration. EPA and partner organizations create valuable and applicable technologies for the marketplace.

  15. Applying human factors principles to alert design increases efficiency and reduces prescribing errors in a scenario-based simulation

    PubMed Central

    Russ, Alissa L; Zillich, Alan J; Melton, Brittany L; Russell, Scott A; Chen, Siying; Spina, Jeffrey R; Weiner, Michael; Johnson, Elizabette G; Daggy, Joanne K; McManus, M Sue; Hawsey, Jason M; Puleo, Anthony G; Doebbeling, Bradley N; Saleem, Jason J

    2014-01-01

    Objective To apply human factors engineering principles to improve alert interface design. We hypothesized that incorporating human factors principles into alerts would improve usability, reduce workload for prescribers, and reduce prescribing errors. Materials and methods We performed a scenario-based simulation study using a counterbalanced, crossover design with 20 Veterans Affairs prescribers to compare original versus redesigned alerts. We redesigned drug–allergy, drug–drug interaction, and drug–disease alerts based upon human factors principles. We assessed usability (learnability of redesign, efficiency, satisfaction, and usability errors), perceived workload, and prescribing errors. Results Although prescribers received no training on the design changes, prescribers were able to resolve redesigned alerts more efficiently (median (IQR): 56 (47) s) compared to the original alerts (85 (71) s; p=0.015). In addition, prescribers rated redesigned alerts significantly higher than original alerts across several dimensions of satisfaction. Redesigned alerts led to a modest but significant reduction in workload (p=0.042) and significantly reduced the number of prescribing errors per prescriber (median (range): 2 (1–5) compared to original alerts: 4 (1–7); p=0.024). Discussion Aspects of the redesigned alerts that likely contributed to better prescribing include design modifications that reduced usability-related errors, providing clinical data closer to the point of decision, and displaying alert text in a tabular format. Displaying alert text in a tabular format may help prescribers extract information quickly and thereby increase responsiveness to alerts. Conclusions This simulation study provides evidence that applying human factors design principles to medication alerts can improve usability and prescribing outcomes. PMID:24668841

  16. Applying human factors principles to alert design increases efficiency and reduces prescribing errors in a scenario-based simulation.

    PubMed

    Russ, Alissa L; Zillich, Alan J; Melton, Brittany L; Russell, Scott A; Chen, Siying; Spina, Jeffrey R; Weiner, Michael; Johnson, Elizabette G; Daggy, Joanne K; McManus, M Sue; Hawsey, Jason M; Puleo, Anthony G; Doebbeling, Bradley N; Saleem, Jason J

    2014-10-01

    To apply human factors engineering principles to improve alert interface design. We hypothesized that incorporating human factors principles into alerts would improve usability, reduce workload for prescribers, and reduce prescribing errors. We performed a scenario-based simulation study using a counterbalanced, crossover design with 20 Veterans Affairs prescribers to compare original versus redesigned alerts. We redesigned drug-allergy, drug-drug interaction, and drug-disease alerts based upon human factors principles. We assessed usability (learnability of redesign, efficiency, satisfaction, and usability errors), perceived workload, and prescribing errors. Although prescribers received no training on the design changes, prescribers were able to resolve redesigned alerts more efficiently (median (IQR): 56 (47) s) compared to the original alerts (85 (71) s; p=0.015). In addition, prescribers rated redesigned alerts significantly higher than original alerts across several dimensions of satisfaction. Redesigned alerts led to a modest but significant reduction in workload (p=0.042) and significantly reduced the number of prescribing errors per prescriber (median (range): 2 (1-5) compared to original alerts: 4 (1-7); p=0.024). Aspects of the redesigned alerts that likely contributed to better prescribing include design modifications that reduced usability-related errors, providing clinical data closer to the point of decision, and displaying alert text in a tabular format. Displaying alert text in a tabular format may help prescribers extract information quickly and thereby increase responsiveness to alerts. This simulation study provides evidence that applying human factors design principles to medication alerts can improve usability and prescribing outcomes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Provider acceptance of an automated electronic alert for acute kidney injury

    PubMed Central

    Oh, Janice; Bia, Joshua R.; Ubaid-Ullah, Muhamad; Testani, Jeffrey M.; Wilson, Francis Perry

    2016-01-01

    Background Clinical decision support systems, including electronic alerts, ideally provide immediate and relevant patient-specific information to improve clinical decision-making. Despite the growing capabilities of such alerts in conjunction with an expanding electronic medical record, there is a paucity of information regarding their perceived usefulness. We surveyed healthcare providers' opinions concerning the practicality and efficacy of a specific text-based automated electronic alert for acute kidney injury (AKI) in a single hospital during a randomized trial of AKI alerts. Methods Providers who had received at least one electronic AKI alert in the previous 6 months, as part of a separate randomized controlled trial (clinicaltrials.gov #01862419), were asked to complete a survey concerning their opinions about this specific AKI alert system. Individual approval of the alert system was defined by a provider's desire to continue receiving the alert after termination of the trial. Results A total of 98 individuals completed the survey, including 62 physicians, 27 pharmacists and 7 non-physician providers. Sixty-nine percent of responders approved the alert, with no significant difference among the various professions (P = 0.28). Alert approval was strongly correlated with the belief that the alerts improved patient care (P < 0.0001), and negatively correlated with the belief that alerts did not provide novel information (P = 0.0001). With each additional 30 days of trial duration, odds of approval decreased by 20% (3–35%) (P = 0.02). Conclusions The alert system was generally well received, although approval waned with time. Approval was correlated with the belief that this type of alert improved patient care. These findings suggest that perceived efficacy is critical to the success of future alert trials. PMID:27478598

  18. Making electronic prescribing alerts more effective: scenario-based experimental study in junior doctors

    PubMed Central

    Shah, Priya; Wyatt, Jeremy C; Makubate, Boikanyo; Cross, Frank W

    2011-01-01

    Objective Expert authorities recommend clinical decision support systems to reduce prescribing error rates, yet large numbers of insignificant on-screen alerts presented in modal dialog boxes persistently interrupt clinicians, limiting the effectiveness of these systems. This study compared the impact of modal and non-modal electronic (e-) prescribing alerts on prescribing error rates, to help inform the design of clinical decision support systems. Design A randomized study of 24 junior doctors each performing 30 simulated prescribing tasks in random order with a prototype e-prescribing system. Using a within-participant design, doctors were randomized to be shown one of three types of e-prescribing alert (modal, non-modal, no alert) during each prescribing task. Measurements The main outcome measure was prescribing error rate. Structured interviews were performed to elicit participants' preferences for the prescribing alerts and their views on clinical decision support systems. Results Participants exposed to modal alerts were 11.6 times less likely to make a prescribing error than those not shown an alert (OR 11.56, 95% CI 6.00 to 22.26). Those shown a non-modal alert were 3.2 times less likely to make a prescribing error (OR 3.18, 95% CI 1.91 to 5.30) than those not shown an alert. The error rate with non-modal alerts was 3.6 times higher than with modal alerts (95% CI 1.88 to 7.04). Conclusions Both kinds of e-prescribing alerts significantly reduced prescribing error rates, but modal alerts were over three times more effective than non-modal alerts. This study provides new evidence about the relative effects of modal and non-modal alerts on prescribing outcomes. PMID:21836158

  19. 76 FR 71033 - Federal Advisory Committee Act; Technological Advisory Council

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-16

    ... FEDERAL COMMUNICATIONS COMMISSION Federal Advisory Committee Act; Technological Advisory Council... Communications Commission's (FCC) Technological Advisory Council will hold a meeting on Tuesday, December 20... in progress and discuss potential agendas for the coming year. The FCC will attempt to accommodate as...

  20. Provider management strategies of abnormal test result alerts: a cognitive task analysis

    PubMed Central

    Sawhney, Mona K; Wilson, Lindsay; Sittig, Dean F; Espadas, Donna; Davis, Traber; Singh, Hardeep

    2010-01-01

    Objective Electronic medical records (EMRs) facilitate abnormal test result communication through “alert” notifications. The aim was to evaluate how primary care providers (PCPs) manage alerts related to critical diagnostic test results on their EMR screens, and compare alert-management strategies of providers with high versus low rates of timely follow-up of results. Design 28 PCPs from a large, tertiary care Veterans Affairs Medical Center (VAMC) were purposively sampled according to their rates of timely follow-up of alerts, determined in a previous study. Using techniques from cognitive task analysis, participants were interviewed about how and when they manage alerts, focusing on four alert-management features to filter, sort and reduce unnecessary alerts on their EMR screens. Results Provider knowledge of alert-management features ranged between 4% and 75%. Almost half (46%) of providers did not use any of these features, and none used more than two. Providers with higher versus lower rates of timely follow-up used the four features similarly, except one (customizing alert notifications). Providers with low rates of timely follow-up tended to manually scan the alert list and process alerts heuristically using their clinical judgment. Additionally, 46% of providers used at least one workaround strategy to manage alerts. Conclusion Considerable heterogeneity exists in provider use of alert-management strategies; specific strategies may be associated with lower rates of timely follow-up. Standardization of alert-management strategies including improving provider knowledge of appropriate tools in the EMR to manage alerts could reduce the lack of timely follow-up of abnormal diagnostic test results. PMID:20064805

  1. Bladder Monitor

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Diagnostic Ultrasound Corporation's Bladder Scan Monitor continuously records and monitors bladder fullness and alerts the wearer or caretaker when voiding is required. The sensor is held against the lower abdomen by a belt and connected to the monitor by a cable. The sensor obtains bladder volume data from sound waves reflecting off the bladder wall. The device was developed by Langley Research Center, the Ames Research Center and the NASA Technology Applications Team. It utilizes Langley's advanced ultrasound technology. It is licensed to the ARC for medical applications, and sublicensed to Diagnostics Ultrasound. Central monitoring systems are planned for the future.

  2. THE TSUNAMI SERVICE BUS, AN INTEGRATION PLATFORM FOR HETEROGENEOUS SENSOR SYSTEMS

    NASA Astrophysics Data System (ADS)

    Fleischer, J.; Häner, R.; Herrnkind, S.; Kriegel, U.; Schwarting, H.; Wächter, J.

    2009-12-01

    The Tsunami Service Bus (TSB) is the sensor integration platform of the German Indonesian Tsunami Early Warning System (GITEWS) [1]. The primary goal of GITEWS is to deliver reliable tsunami warnings as fast as possible. This is achieved on basis of various sensor systems like seismometers, ocean instrumentation, and GPS stations, all providing fundamental data to support prediction of tsunami wave propagation by the GITEWS warning center. However, all these sensors come with their own proprietary data formats and specific behavior. Also new sensor types might be added, old sensors will be replaced. To keep GITEWS flexible the TSB was developed in order to access and control sensors in a uniform way. To meet these requirements the TSB follows the architectural blueprint of a Service Oriented Architecture (SOA). The integration platform implements dedicated services communicating via a service infrastructure. The functionality required for early warnings is provided by loosely coupled services replacing the "hard-wired" coupling at data level. Changes in the sensor specification are confined to the data level without affecting the warning center. Great emphasis was laid on following the Sensor Web Enablement (SWE) standard [2], specified by the Open Geospatial Consortium (OGC) [3]. As a result the full functionality needed in GITEWS could be achieved by implementing the four SWE services: The Sensor Observation Service for retrieving sensor measurements, the Sensor Alert Service in order to deliver sensor alerts, the Sensor Planning Service for tasking sensors, and the Web Notification Service for conduction messages to various media channels. Beyond these services the TSB also follows SWE Observation & Measurements specifications (O&M) for data encoding and Sensor Model Language (SensorML) for meta information. Moreover, accessing sensors via the TSB is not restricted to GITEWS. Multiple instances of the TSB can be composed to realize federate warning system. Beside the already operating TSB at the BMKG warning center [4], two other organizations in Indonesia ([5], [6]) consider using the TSB, making their data centers available to GITEWS. The presentation takes a look at the concepts and implementation and reflects the usefulness of the mentioned standards. REFERENCES [1] GITEWS is a project of the German Federal Government to aid the recon¬struction of the tsunami-prone region of the Indian Ocean, http://www.gitews.org/ [2] SWE, www.opengeospatial.org/projects/groups/sensorweb [3] OGC, www.opengeospatial.org [4] Meteorological and Geophysical Agency of Indonesia (BMKG), www.bmg.go.id [5] National Coordinating Agency for Surveys and Mapping (BAKOSURTANAL), www.bakosurtanal.go.id [6] Agency for the Assessment & Application of Technology (BPPT), www.bppt.go.id

  3. Structure alerts for carcinogenicity, and the Salmonella assay system: a novel insight through the chemical relational databases technology.

    PubMed

    Benigni, Romualdo; Bossa, Cecilia

    2008-01-01

    In the past decades, chemical carcinogenicity has been the object of mechanistic studies that have been translated into valuable experimental (e.g., the Salmonella assays system) and theoretical (e.g., compilations of structure alerts for chemical carcinogenicity) models. These findings remain the basis of the science and regulation of mutagens and carcinogens. Recent advances in the organization and treatment of large databases consisting of both biological and chemical information nowadays allows for a much easier and more refined view of data. This paper reviews recent analyses on the predictive performance of various lists of structure alerts, including a new compilation of alerts that combines previous work in an optimized form for computer implementation. The revised compilation is part of the Toxtree 1.50 software (freely available from the European Chemicals Bureau website). The use of structural alerts for the chemical biological profiling of a large database of Salmonella mutagenicity results is also reported. Together with being a repository of the science on the chemical biological interactions at the basis of chemical carcinogenicity, the SAs have a crucial role in practical applications for risk assessment, for: (a) description of sets of chemicals; (b) preliminary hazard characterization; (c) formation of categories for e.g., regulatory purposes; (d) generation of subsets of congeneric chemicals to be analyzed subsequently with QSAR methods; (e) priority setting. An important aspect of SAs as predictive toxicity tools is that they derive directly from mechanistic knowledge. The crucial role of mechanistic knowledge in the process of applying (Q)SAR considerations to risk assessment should be strongly emphasized. Mechanistic knowledge provides a ground for interaction and dialogue between model developers, toxicologists and regulators, and permits the integration of the (Q)SAR results into a wider regulatory framework, where different types of evidence and data concur or complement each other as a basis for making decisions and taking actions.

  4. Geoethical issues involved in Tsunami Warning System concepts and operations

    NASA Astrophysics Data System (ADS)

    Charalampakis, Marinos; Papadopoulos, Gerassimos A.; Tinti, Stefano

    2016-04-01

    The main goal of a Tsunami Warning System (TWS) is to mitigate the effect of an incoming tsunami by alerting coastal population early enough to allow people to evacuate safely from inundation zones. Though this representation might seem oversimplified, nonetheless, achieving successfully this goal requires a positive synergy of geoscience, communication, emergency management, technology, education, social sciences, politics. Geoethical issues arise always when there is an interaction between geoscience and society, and TWS is a paradigmatic case where interaction is very strong and is made critical because a) the formulation of the tsunami alert has to be made in a time as short as possible and therefore on uncertain data, and b) any evaluation error (underestimation or overestimation) can lead to serious (and sometimes catastrophic) consequences involving wide areas and a large amount of population. From the geoethical point of view three issues are critical: how to (i) combine forecasts and uncertainties reasonably and usefully, (ii) cope and possibly solve the dilemma whether it is better over-alerting or under-alerting population and (iii) deal with responsibility and liability of geoscientists, TWS operators, emergency operators and coastal population. The discussion will be based on the experience of the Hellenic National Tsunami Warning Center (HL-NTWC, Greece), which operates on 24/7 basis as a special unit of the Institute of Geodynamics, National Observatory of Athens, and acts also as Candidate Tsunami Service Provider (CTSP) in the framework of the North-Eastern Atlantic, the Mediterranean and connected seas Tsunami Warning System (NEAMTWS) of the IOC/UNESCO. Since August 2012, when HL-NTWC was officially declared as operational, 14 tsunami warning messages have been disseminated to a large number of subscribers after strong submarine earthquakes occurring in Greece and elsewhere in the eastern Mediterranean. It is recognized that the alerting process and procedure are quite complex and deserve an open and wide debate, that at the moment seems to be absent from media, scientific community and society, very likely until the next tsunami disaster.

  5. Digital technology in respiratory diseases: Promises, (no) panacea and time for a new paradigm.

    PubMed

    Pinnock, Hilary; McKinstry, Brian

    2016-05-01

    In a world where digital technology has revolutionized the way we work, shop and manage our finances it is unsurprising that digital systems are suggested as potential solutions to delivering clinically and cost-effective care for an aging population with one or more long-term conditions. However, recent evidence suggesting that telehealth may not be quite the panacea that was promised, has led to discussions on the mechanisms and role of digital technology in respiratory care. Implementation in rural and remote settings offers significant benefits in terms of convenient access to care, but is contingent on technical and organizational infrastructure. Telemonitoring systems rely on algorithms to detect deterioration and trigger alerts; machine learning may enable telemonitoring of the future to develop personalized systems that are sensitive to clinical status whilst reducing false alerts. By providing access to information, offering convenient and flexible modes of communication and enabling the transfer of monitoring data to support professional assessment, telehealth can support self-management. At present, all too often, expensive 'off the shelf' systems are purchased and given to clinicians to use. It is time for the paradigm to shift. As clinicians we should identify the specific challenges we face in delivering care, and expect flexible systems that can be customized to individual patients' requirements and adapted to our diverse healthcare contexts. © The Author(s) 2016.

  6. Temporal Informative Analysis in Smart-ICU Monitoring: M-HealthCare Perspective.

    PubMed

    Bhatia, Munish; Sood, Sandeep K

    2016-08-01

    The rapid introduction of Internet of Things (IoT) Technology has boosted the service deliverance aspects of health sector in terms of m-health, and remote patient monitoring. IoT Technology is not only capable of sensing the acute details of sensitive events from wider perspectives, but it also provides a means to deliver services in time sensitive and efficient manner. Henceforth, IoT Technology has been efficiently adopted in different fields of the healthcare domain. In this paper, a framework for IoT based patient monitoring in Intensive Care Unit (ICU) is presented to enhance the deliverance of curative services. Though ICUs remained a center of attraction for high quality care among researchers, still number of studies have depicted the vulnerability to a patient's life during ICU stay. The work presented in this study addresses such concerns in terms of efficient monitoring of various events (and anomalies) with temporal associations, followed by time sensitive alert generation procedure. In order to validate the system, it was deployed in 3 ICU room facilities for 30 days in which nearly 81 patients were monitored during their ICU stay. The results obtained after implementation depicts that IoT equipped ICUs are more efficient in monitoring sensitive events as compared to manual monitoring and traditional Tele-ICU monitoring. Moreover, the adopted methodology for alert generation with information presentation further enhances the utility of the system.

  7. Does one hour of bright or short-wavelength filtered tablet screenlight have a meaningful effect on adolescents' pre-bedtime alertness, sleep, and daytime functioning?

    PubMed

    Heath, Melanie; Sutherland, Cate; Bartel, Kate; Gradisar, Michael; Williamson, Paul; Lovato, Nicole; Micic, Gorica

    2014-05-01

    Electronic media use is prevalent among adolescent populations, as is the frequency of sleeplessness. One mechanism proposed for technology affecting adolescents' sleep is the alerting effects from bright screens. Two explanations are provided. First, screens emit significant amounts of short-wavelength light (i.e. blue), which produces acute alertness and alters sleep timing. Second, later chronotypes are hypothesised to be hypersensitive to evening light. This study analysed the pre-sleep alertness (GO/NOGO task speed, accuracy; subjective sleepiness), sleep (sleep diary, polysomnography), and morning functioning of 16 healthy adolescents (M = 17.4 ± 1.9 yrs, 56% f) who used a bright tablet screen (80 lux), dim screen (1 lux) and a filtered short-wavelength screen (f.lux; 50 lux) for 1 hr before their usual bedtime in a within-subjects protocol. Chronotype was analysed as a continuous between-subjects factor; however, no significant interactions occurred. Significant effects occurred between bright and dim screens for GO/NOGO speed and accuracy. However, the magnitude of these differences was small (e.g. GO/NOGO speed = 23 ms, accuracy = 13%), suggesting minimal clinical significance. No significant effects were found for sleep onset latency, slow-rolling eye movements, or the number of SWS and REM minutes in the first two sleep cycles. Future independent studies are needed to test short (1 hr) vs longer (>2 hrs) screen usage to provide evidence for safe-to-harmful levels of screenlight exposure before adolescents' usual bedtime.

  8. Evaluation of the attention network test using vibrotactile stimulations.

    PubMed

    Salzer, Yael; Oron-Gilad, Tal; Henik, Avishai

    2015-06-01

    We report a vibrotactile version of the attention network test (ANT)-the tactile ANT (T-ANT). It has been questioned whether attentional components are modality specific or not. The T-ANT explores alertness, orienting, cognitive control, and their relationships, similar to its visual counterpart, in the tactile modality. The unique features of the T-ANT are in utilizing stimuli on a single plane-the torso-and replacing the original imperative flanker task with a tactile Simon task. Subjects wore a waist belt mounted with two vibrotactile stimulators situated on the back and positioned to the right and left of the spinal column. They responded by pressing keys with their right or left hand in reaction to the type of vibrotactile stimulation (pulsed/continuous signal). On a single trial, an alerting tone was followed by a short tactile (informative/noninformative) peripheral cue and an imperative tactile Simon task target. The T-ANT was compared with a variant of the ANT in which the flanker task was replaced with a visual Simon task. Experimental data showed effects of orienting over control only when the peripheral cues were informative. In contrast to the visual task, interactions between alertness and control or alertness and orienting were not found in the tactile task. A possible rationale for these results is discussed. The T-ANT allows examination of attentional processes among patients with tactile attentional deficits and patients with eyesight deficits who cannot take part in visual tasks. Technological advancement would enable implementation of the T-ANT in brain-imaging studies.

  9. The effect of phasic auditory alerting on visual perception.

    PubMed

    Petersen, Anders; Petersen, Annemarie Hilkjær; Bundesen, Claus; Vangkilde, Signe; Habekost, Thomas

    2017-08-01

    Phasic alertness refers to a short-lived change in the preparatory state of the cognitive system following an alerting signal. In the present study, we examined the effect of phasic auditory alerting on distinct perceptual processes, unconfounded by motor components. We combined an alerting/no-alerting design with a pure accuracy-based single-letter recognition task. Computational modeling based on Bundesen's Theory of Visual Attention was used to examine the effect of phasic alertness on visual processing speed and threshold of conscious perception. Results show that phasic auditory alertness affects visual perception by increasing the visual processing speed and lowering the threshold of conscious perception (Experiment 1). By manipulating the intensity of the alerting cue, we further observed a positive relationship between alerting intensity and processing speed, which was not seen for the threshold of conscious perception (Experiment 2). This was replicated in a third experiment, in which pupil size was measured as a physiological marker of alertness. Results revealed that the increase in processing speed was accompanied by an increase in pupil size, substantiating the link between alertness and processing speed (Experiment 3). The implications of these results are discussed in relation to a newly developed mathematical model of the relationship between levels of alertness and the speed with which humans process visual information. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Preventing dispensing errors by alerting for drug confusions in the pharmacy information system-A survey of users.

    PubMed

    Campmans, Zizi; van Rhijn, Arianne; Dull, René M; Santen-Reestman, Jacqueline; Taxis, Katja; Borgsteede, Sander D

    2018-01-01

    Drug confusion is thought to be the most common type of dispensing error. Several strategies can be implemented to reduce the risk of medication errors. One of these are alerts in the pharmacy information system. To evaluate the experiences of pharmacists and pharmacy technicians with alerts for drug name and strength confusion. In May 2017, a cross-sectional survey of pharmacists and pharmacy technicians was performed in community pharmacies in the Netherlands using an online questionnaire. Of the 269 respondents, 86% (n = 230) had noticed the alert for drug name confusion, and 26% (n = 67) for drug strength confusion. Of those 230, 9% (n = 20) had experienced that the alert had prevented dispensing the wrong drug. For drug strength confusion, this proportion was 12% (n = 8). Respondents preferred to have an alert for drug name and strength confusion in the pharmacy information system. 'Alert fatigue' was an important issue, so alerts should only be introduced for frequent confusions or confusions with serious consequences. Pharmacists and pharmacy technicians were positive about having alerts for drug confusions in their pharmacy information system and experienced that alerts contributed to the prevention of dispensing errors. To prevent alert fatigue, it was considered important not to include all possible confusions as a new alert: the potential contribution to the prevention of drug confusion should be weighed against the risk of alert fatigue.

  11. Federal/State Jurisdictional Split: Implications for Emerging Electricity Technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dennis, Jeffery S.; Kelly, Suedeen G.; Nordhaus, Robert R.

    The first Administration-wide Quadrennial Energy Review (QER), released in April 2015, found that the “interacting and overlapping” division of authority between “federal, regional and state institutions and regulatory structures” for the electricity sector could “impede development of the grid of the future [and] . . . the development of markets that efficiently integrate” new and emerging technologies.1 While “technology is indifferent to state-Federal boundaries and jurisdictions,” the QER explained, “technology users cannot be.”2 The report concluded that “[b]oth Federal and state governments need to play constructive and collaborative roles in the future to ensure that consumers and industry are ablemore » to maximize the value of new technologies.”3 The QER recommended that the Department of Energy (“DOE”) facilitate such collaboration by playing a “convening role” to bring together state and federal regulators and other stakeholders to consider these issues.4 This paper provides background and analysis on these jurisdictional issues and the impact they may have on adoption of emerging energy technologies and coordination of markets for those technologies, in support of future dialogs on these subjects. In particular, this paper reviews the structure of the Federal Power Act (“FPA”),5 and compares the division of authority between the federal and state governments adopted there with other federal energy and energy-related statutes.« less

  12. Technology: Transforming Federal Training. Report to the President.

    ERIC Educational Resources Information Center

    President's Task Force on Federal Training Technology, Washington, DC.

    The federal government's ability to provide the services and products that the American public expects depends on the talents and skills of the federal workforce. Therefore, federal employees must undertake retraining to learn new skills. Accelerating the use of learning technology will contribute to the learning process. A federal task force on…

  13. Can A Self-Diagnostic Digitally Controlled Pacemaker/Defibrillator Device be Used For Alerting Military Personnel When a Soldier Health Condition Becomes Compromised Out in the Field

    DTIC Science & Technology

    2006-09-26

    its technology began over 200 years ago when such pioneers as Luigi Galvani and Alessandro Volta brought about the awareness of electricity...biology, and electro-chemistry. Volta , whose name is synonymous with the rating of batteries (Volts), did remarkable studies in the area of electricity

  14. Can a Self-Diagnostic Digitally Controlled Pacemaker/Defibrillator Device be Used for Alerting Military Personnel When a Soldier Health Condition Becomes Compromised Out in the Field

    DTIC Science & Technology

    2007-01-26

    its technology began over 200 years ago when such pioneers as Luigi Galvani and Alessandro Volta brought about the awareness of electricity...biology, and electro-chemistry. Volta , whose name is synonymous with the rating of batteries (Volts), did remarkable studies in the area of electricity

  15. Afterschool: A Natural Platform for Career Development. Afterschool Alert. Issue Brief No. 19

    ERIC Educational Resources Information Center

    Afterschool Alliance, 2004

    2004-01-01

    As technology evolves and the economy changes, greater demands will be placed on the workforce of the future. Myriad opportunities are and will be available to those who have the knowledge and the skills to meet those challenges. Afterschool programs offer a key opportunity to expose students to ideas and teach them skills that can unlock doors to…

  16. JPRS Report, Science and Technology USSR: Life Sciences.

    DTIC Science & Technology

    1990-10-02

    13 Epidemiology of HIV Infection in USSR [V. V. Pokrovskiy, L Yu. Yeramova, et al...tetracycline- resistant clones of this plasmid, obtained in vitro by the This paper examines the molecular epidemiological fea- prescribed method...noted in the last decade; it cases of illness, and a high proportion of late diagnoses is associated with a decline in epidemiological alertness owing

  17. Resolving the Problem of Aligning Communities of Interest, Data Format Differences, Orthogonal Sensor Views, Intermittency, and Security - DoD Homeland Security Command and Control Advanced Concept Technology Demonstration

    DTIC Science & Technology

    2005-06-01

    provisioning, maintaining and guaranteeing service levels for the shared services ? Although these shared, distributed services lie well within the... shared services that interact with a common object definition for transporting alerts. The system is built on top of a rapid SOA application

  18. Effectiveness of a Mobile Short-Message-Service–Based Disease Outbreak Alert System in Kenya

    PubMed Central

    Njeru, Ian; Zurovac, Dejan; Tipo, Shikanga O; Kareko, David; Mwau, Matilu; Morita, Kouichi

    2016-01-01

    We conducted a randomized, controlled trial to test the effectiveness of a text-messaging system used for notification of disease outbreaks in Kenya. Health facilities that used the system had more timely notifications than those that did not (19.2% vs. 2.6%), indicating that technology can enhance disease surveillance in resource-limited settings. PMID:26981628

  19. Human Factors Considerations for Safe Recovery from Faults In Flight Control Systems

    NASA Technical Reports Server (NTRS)

    Pritchett, Amy; Belcastro, C. M. (Technical Monitor)

    2003-01-01

    It is now possible - and important - to develop systems to help resolve Flight Control System (FCS) faults. From a human factors viewpoint, it is imperative that these systems take on roles, and provide functions, that are the most supportive to the pilot, given the stress, time pressure and workload they may experience following a FCS fault. FCS fault recovery systems may provide several different functions, including alerting, control assistance, and decision aiding. The biggest human factors questions are in the role suitable for the technology, and its specific functioning to achieve that role. Specifically, for these systems to be effective, they must meet the fundamental requirements that (1) they alert pilots to problems early enough that the pilot can reasonably resolve the fault and regain control of the aircraft and that (2) if the aircraft s handling qualities are severely degraded the HMS provide the appropriate stability augmentation to help the pilot stabilize and control the aircraft. This project undertook several research steps to develop such systems, focusing on the capabilities of pilots and on realistically attainable technologies. The ability to estimate which functions are the most valuable will help steer system development in the directions that can establish the highest safety levels.

  20. Reducing duplicate testing: a comparison of two clinical decision support tools.

    PubMed

    Procop, Gary W; Keating, Catherine; Stagno, Paul; Kottke-Marchant, Kandice; Partin, Mary; Tuttle, Robert; Wyllie, Robert

    2015-05-01

    Unnecessary duplicate laboratory testing is common and costly. Systems-based means to avert unnecessary testing should be investigated and employed. We compared the effectiveness and cost savings associated with two clinical decision support tools to stop duplicate testing. The Hard Stop required telephone contact with the laboratory and justification to have the duplicate test performed, whereas the Smart Alert allowed the provider to bypass the alert at the point of order entry without justification. The Hard Stop alert was significantly more effective than the Smart Alert (92.3% vs 42.6%, respectively; P < .0001). The cost savings realized per alert activation was $16.08/alert for the Hard Stop alert vs $3.52/alert for the Smart Alert. Structural and process changes that require laboratory contact and justification for duplicate testing are more effective than interventions that allow providers to bypass alerts without justification at point of computerized physician order entry. Copyright© by the American Society for Clinical Pathology.

Top