Xing, Junchao; Jin, Huiyong; Hou, Tianyong; Chang, Zhengqi; Luo, Fei; Wang, Pinpin; Li, Zhiqiang; Xie, Zhao; Xu, Jianzhong
2014-12-01
To understand the cellular mechanism underlying bone defect healing in the context of tissue engineering, a reliable, reproducible, and standardized load-bearing large segmental bone defect model in small animals is indispensable. The aim of this study was to establish and evaluate a bilateral femoral defect model in mice. Donor mouse bone marrow mesenchymal stem cells (mBMSCs) were obtained from six mice (FVB/N) and incorporated into partially demineralized bone matrix scaffolds to construct tissue-engineered bones. In total, 36 GFP(+) mice were used for modeling. Titanium fixation plates with locking steel wires were attached to the femurs for stabilization, and 2-mm-long segmental bone defects were created in the bilateral femoral midshafts. The defects in the left and right femurs were transplanted with tissue-engineered bones and control scaffolds, respectively. The healing process was monitored by x-ray radiography, microcomputed tomography, and histology. The capacity of the transplanted mBMSCs to recruit host CD31(+) cells was investigated by immunofluorescence and real-time polymerase chain reaction. Postoperatively, no complication was observed, except that two mice died of unknown causes. Stable fixation of femurs and implants with full load bearing was achieved in all animals. The process of bone defect repair was significantly accelerated due to the introduction of mBMSCs. Moreover, the transplanted mBMSCs attracted more host CD31(+) endothelial progenitors into the grafts. The present study established a feasible, reproducible, and clinically relevant bilateral femoral large segmental bone defect mouse model. This model is potentially suitable for basic research in the field of bone tissue engineering. Copyright © 2014 Elsevier Inc. All rights reserved.
Chen, Shuang-Tao; Zhang, Wei-Ping; Liu, Chang-An; Wang, Jun-Jiang; Song, Heng-Yi; Chai, Zhi-wen
2013-03-01
To discuss the feasibility of vascular bundle implantation combined with allogeneic bone marrow stromal cells (BMSCs) transplantation in treating rabbit femoral head osteonecrosis and bone defect, in order to explore a new method for the treatment of femoral head necrosis. Thirty-six New Zealand rabbits were randomly divided into three groups,with 12 rabbits in each group. Bilateral femoral heads of the rabbits were studied in the experiment. The models were made by liquid nitrogen frozen, and the femoral heads were drilled to cause bone defect. Group A was the control group,group B was stem cells transplantaion group of allograft marrow stromal,and group C was stem cells transplantation group of allograft marrow stromal combined with vascular bundle implantation. Three rabbits of each group were sacrificed respectively at 2, 4, 8, 12 weeks after operation. All specimens of the femoral heads were sliced for HE staining. Furthermore ,vascular density and the percentage of new bone trabecula of femoral head coronary section in defect area were measured and analyzed statistically. In group C,new bone trabecula and original micrangium formed at the 2nd week after operation; new bone trabecula was lamellar and interlaced with abundant micrangium at the 8th week;at the 12th week,the broadened,coarsened bone trabecula lined up regularly,and the mature bone trabecula and new marrow were visible. At the 2nd week after operation,there was no statistical significance in the percentage of new bone trabecula of femoral head coronary section in defect area between group B and C. While at 4, 8, 12 week after operation, vascular density and the percentage of new bone trabecula of femoral head coronary section in defect area of group C was higher than that of group B. Allogeneic bone marrow stromal cells cultured in vivo can form new bone trabecula, and can be applied to allotransplant. Vascular bundle implanted into the bone defect area of femoral head necrosis could improve blood supply, and promote the formation of bone trabecula.
Zara, Janette N; Siu, Ronald K; Zhang, Xinli; Shen, Jia; Ngo, Richard; Lee, Min; Li, Weiming; Chiang, Michael; Chung, Jonguk; Kwak, Jinny; Wu, Benjamin M; Ting, Kang; Soo, Chia
2011-05-01
The major Food and Drug Association-approved osteoinductive factors in wide clinical use are bone morphogenetic proteins (BMPs). Although BMPs can promote robust bone formation, they also induce adverse clinical effects, including cyst-like bone formation and significant soft tissue swelling. In this study, we evaluated multiple BMP2 doses in a rat femoral segmental defect model and in a minimally traumatic rat femoral onlay model to determine its dose-dependent effects. Results of our femoral segmental defect model established a low BMP2 concentration range (5 and 10 μg/mL, total dose 0.375 and 0.75 μg in 75 μg total volume) unable to induce defect fusion, a mid-range BMP2 concentration range able to fuse the defect without adverse effects (30 μg/mL, total dose 2.25 μg in 75 μg total volume), and a high BMP2 concentration range (150, 300, and 600 μg/mL, total dose 11.25, 22.5, and 45 μg in 75 μg total volume) able to fuse the defect, but with formation of cyst-like bony shells filled with histologically confirmed adipose tissue. In addition, compared to control, 4 mg/mL BMP2 also induced significant tissue inflammatory infiltrates and exudates in the femoral onlay model that was accompanied by increased numbers of osteoclast-like cells at 3, 7, and 14 days. Overall, we consistently reproduced BMP2 side effects of cyst-like bone and soft tissue swelling using high BMP2 concentration approaching the typical human 1500 μg/mL.
Zara, Janette N.; Siu, Ronald K.; Zhang, Xinli; Shen, Jia; Ngo, Richard; Lee, Min; Li, Weiming; Chiang, Michael; Chung, Jonguk; Kwak, Jinny; Wu, Benjamin M.; Ting, Kang
2011-01-01
The major Food and Drug Association–approved osteoinductive factors in wide clinical use are bone morphogenetic proteins (BMPs). Although BMPs can promote robust bone formation, they also induce adverse clinical effects, including cyst-like bone formation and significant soft tissue swelling. In this study, we evaluated multiple BMP2 doses in a rat femoral segmental defect model and in a minimally traumatic rat femoral onlay model to determine its dose-dependent effects. Results of our femoral segmental defect model established a low BMP2 concentration range (5 and 10 μg/mL, total dose 0.375 and 0.75 μg in 75 μg total volume) unable to induce defect fusion, a mid-range BMP2 concentration range able to fuse the defect without adverse effects (30 μg/mL, total dose 2.25 μg in 75 μg total volume), and a high BMP2 concentration range (150, 300, and 600 μg/mL, total dose 11.25, 22.5, and 45 μg in 75 μg total volume) able to fuse the defect, but with formation of cyst-like bony shells filled with histologically confirmed adipose tissue. In addition, compared to control, 4 mg/mL BMP2 also induced significant tissue inflammatory infiltrates and exudates in the femoral onlay model that was accompanied by increased numbers of osteoclast-like cells at 3, 7, and 14 days. Overall, we consistently reproduced BMP2 side effects of cyst-like bone and soft tissue swelling using high BMP2 concentration approaching the typical human 1500 μg/mL. PMID:21247344
Hannon, Charles P; Weber, Alexander E; Gitelis, Matthew; Meyer, Maximillian A; Yanke, Adam B; Cole, Brian J
2018-04-01
To compare the osteochondral allograft (OCA) outcomes of bipolar defects with isolated femoral defects and to investigate the optimal treatment of bipolar defects by comparing femoral OCA with tibial debridement to femoral OCA and tibial microfracture. A series of patients with 2-year follow-up from March 2004 to September 2015 after femoral OCA for bipolar chondral defects was identified. Group 1 contained patients with tibial defects treated with debridement and group 2 contained patients with microfractured tibial defects. A third group (group 3) with isolated femoral defects treated with OCA was identified and matched by gender, body mass index (BMI), laterality, and OCA size to groups 1 and 2. Patient-specific, defect-specific, intraoperative, and postoperative data including patient-reported outcomes were collected on all patients. The study groups were compared using analyses of variance, paired sample t tests, and χ-square analyses. Thirty-six patients who had femoral OCA for bipolar lesions were identified with 20 patients in group 1 and 16 patients in group 2. Group 3 had 20 patients. There were no differences between the 3 groups in terms of gender (P = .616), BMI (P = .271), number of previous surgeries (P = .451), femoral or tibial defect size (P = .296), and OCA size (P = .981). Preoperative to postoperative patient-reported clinical outcomes (PROs) revealed statistical and clinically meaningful improvement in all 3 groups, but did not differ between groups. Patient-specific and defect-specific factors did not correlate with PROs. The graft survivorship for group 1 was 85% at 4.5 years, 100% for group 2 at 2.5 years, and 95% for group 3 at 3.8 years. Regardless of tibial treatment, patients with bipolar defects treated with femoral OCA have clinically meaningful improvements in PROs and excellent graft survivorship comparable to isolated femoral OCAs at more than 2 years. Level III, case-control study. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Cui, Xu; Huang, Wenhai; Zhang, Yadong; Huang, Chengcheng; Yu, Zunxiong; Wang, Lei; Liu, Wenlong; Wang, Ting; Zhou, Jie; Wang, Hui; Zhou, Nai; Wang, Deping; Pan, Haobo; Rahaman, Mohamed N
2017-04-01
There is a need for synthetic biomaterials to heal bone defects using minimal invasive surgery. In the present study, an injectable cement composed of bioactive borate glass particles and a chitosan bonding solution was developed and evaluated for its capacity to heal bone defects in a rabbit femoral condyle model. The injectability and setting time of the cement in vitro decreased but the compressive strength increased (8±2MPa to 31±2MPa) as the ratio of glass particles to chitosan solution increased (from 1.0gml -1 to 2.5gml -1 ). Upon immersing the cement in phosphate-buffered saline, the glass particles reacted and converted to hydroxyapatite, imparting bioactivity to the cement. Osteoblastic MC3T3-E1 cells showed enhanced proliferation and alkaline phosphatase activity when incubated in media containing the soluble ionic product of the cement. The bioactive glass cement showed a better capacity to stimulate bone formation in rabbit femoral condyle defects at 12weeks postimplantation when compared to a commercial calcium sulfate cement. The injectable bioactive borate glass cement developed in this study could provide a promising biomaterial to heal bone defects by minimal invasive surgery. Copyright © 2016 Elsevier B.V. All rights reserved.
Bucknall, Vittoria; Mehdi, Ali
2013-09-01
Primary total hip arthroplasty can be complicated by acetabular bony defects, threatening the biomechanical integrity of the prosthesis. Traditionally, when autologous bone is used to pack these defects, it is obtained from thin slices of femoral head in addition to acetabular reamings. We report a novel technique for the acquisition of autologous femoral head bone graft used in the reconstruction of acetabular defects during primary total hip arthroplasty. Copyright © 2013 Elsevier Inc. All rights reserved.
Nie, Boyuan; Chen, Xueying; Li, Jing; Wu, Dou; Liu, Qiang
2017-12-28
The major objective of the present study is to investigate the differences in the load and strain changes in the intertrochanteric region of human cadaveric femora between the loss of medial or lateral wall and after treatment with proximal femoral nail antirotation (PFNA). After measuring the geometry of the proximal femur region and modeling the medial or lateral wall defect femoral models, six pairs of freshly frozen human femora were randomly assigned in the medial or lateral wall group. According to a single-leg stance model, an axial loading was applied, and the strain distribution was measured before and after PFNA implantation. The strains of each specimen were recorded at load levels of 350, 700, and 1800 N and the failure load. Paired t test was performed to assess the differences between two groups. The failure mode of almost all defect model femora was consistent with that of the simulated type of intertrochanteric fractures. After the PFNA implantation, the failure mode of almost all stabilized femora was caused by new lateral wall fractures. The failure load of the lateral wall group for defect model femora was significantly higher than that of the medial wall group (p < 0.001). However, the difference disappeared after the PFNA was implanted (p = 0.990). The axial stiffness in all defect model femora showed the same results (p < 0.001). After the PFNA implantation, the axial stiffness of the lateral wall group remained higher than that of the medial wall group (p = 0.001). However, the axial stiffness of the lateral wall group showed that the femora removed from the lateral wall were higher than the PFNA-stabilized femora (p = 0.020). For the axial strain in the anterior wall after the PFNA implantation, the strain of the lateral wall group was significantly lower than that of the medial group (p = 0.003). Nevertheless, for the axial strain of the posterior wall after the PFNA implantation, the strain of the medial wall group was significantly lower than that of the lateral group (p < 0.001). In summary, this study demonstrated that PFNA is an effective intramedullary fixation system for treating unstable intertrochanteric fractures. Compared with the lateral wall, the medial femoral wall is a more important part in the intertrochanteric region. We suggest that in treating intertrochanteric femoral fractures with medial wall fractures, the medial wall fragment should be reset and fixed as much as possible.
Cipitria, Amaia; Boettcher, Kathrin; Schoenhals, Sophia; Garske, Daniela S; Schmidt-Bleek, Katharina; Ellinghaus, Agnes; Dienelt, Anke; Peters, Anja; Mehta, Manav; Madl, Christopher M; Huebsch, Nathaniel; Mooney, David J; Duda, Georg N
2017-09-15
In-situ tissue regeneration aims to utilize the body's endogenous healing capacity through the recruitment of host stem or progenitor cells to an injury site. Stromal cell-derived factor-1α (SDF-1α) is widely discussed as a potent chemoattractant. Here we use a cell-free biomaterial-based approach to (i) deliver SDF-1α for the recruitment of endogenous bone marrow-derived stromal cells (BMSC) into a critical-sized segmental femoral defect in rats and to (ii) induce hydrogel stiffness-mediated osteogenic differentiation in-vivo. Ionically crosslinked alginate hydrogels with a stiffness optimized for osteogenic differentiation were used. Fast-degrading porogens were incorporated to impart a macroporous architecture that facilitates host cell invasion. Endogenous cell recruitment to the defect site was successfully triggered through the controlled release of SDF-1α. A trend for increased bone volume fraction (BV/TV) and a significantly higher bone mineral density (BMD) were observed for gels loaded with SDF-1α, compared to empty gels at two weeks. A trend was also observed, albeit not statistically significant, towards matrix stiffness influencing BV/TV and BMD at two weeks. However, over a six week time-frame, these effects were insufficient for bone bridging of a segmental femoral defect. While mechanical cues combined with ex-vivo cell encapsulation have been shown to have an effect in the regeneration of less demanding in-vivo models, such as cranial defects of nude rats, they are not sufficient for a SDF-1α mediated in-situ regeneration approach in segmental femoral defects of immunocompetent rats, suggesting that additional osteogenic cues may also be required. Stromal cell-derived factor-1α (SDF-1α) is a chemoattractant used to recruit host cells for tissue regeneration. The concept that matrix stiffness can direct mesenchymal stromal cell (MSC) differentiation into various lineages was described a decade ago using in-vitro experiments. Recently, alginate hydrogels with an optimized stiffness and ex-vivo encapsulated MSCs were shown to have an effect in the regeneration of skull defects of nude rats. Here, we apply this material system, loaded with SDF-1α and without encapsulated MSCs, to (i) recruit endogenous cells and (ii) induce stiffness-mediated osteogenic differentiation in-vivo, using as model system a load-bearing femoral defect in immunocompetent rats. While a cell-free approach is of great interest from a translational perspective, the current limitations are described. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Chen, Hongmei; Chevrier, Anik; Hoemann, Caroline D; Sun, Jun; Picard, Genevieve; Buschmann, Michael D
2013-11-01
The influence of the location of cartilage lesions on cartilage repair outcome is incompletely understood. This study compared cartilage and bone repair in medial femoral condylar (MFC) versus femoral trochlear (TR) defects 3 months after bone marrow stimulation in mature rabbits. Intact femurs from adult rabbits served as controls. Results from quantitative histomorphometry and histological scoring showed that bone marrow stimulation produced inferior soft tissue repair in MFC versus TR defects, as indicated by significantly lower % Fill (p = 0.03), a significant increase in collagen type I immunostaining (p < 0.00001) and lower O'Driscoll scores (p < 0.05). 3D micro-CT analysis showed that repaired TR defects regained normal un-operated values of bone volume fraction, trabecular thickness, and trabecular number, whereas in MFC defects the repaired bone architecture appeared immature and less dense compared to intact un-operated MFC controls (p < 0.0001). Severe medial meniscal damage was found in 28% of operated animals and was strongly correlated with (i) low cartilage defect fill, (ii) incomplete bone repair in MFC, and (iii) with a more posterior defect placement in the weight-bearing region. We conclude that the location of cartilage lesions influences cartilage repair, with better outcome in TR versus MFC defects in rabbits. Meniscal degeneration is associated with cartilage damage. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Calcium Sulphate/Hydroxyapatite Carrier for Bone Formation in the Femoral Neck of Osteoporotic Rats.
Sirka, Aurimas; Raina, Deepak Bushan; Isaksson, Hanna; Tanner, K Elizabeth; Smailys, Alfredas; Kumar, Ashok; Tarasevicius, Sarunas; Tägil, Magnus; Lidgren, Lars
2018-06-01
We investigated bone regeneration in the femoral neck canal of osteoporotic rats using a novel animal model. We used a calcium sulphate (CS)/ Hydroxyapatite (HA) carrier to locally deliver a bisphosphonate, zoledronic acid (ZA), with or without added recombinant human bone morphogenic protein-2 (rhBMP-2). Ovariectomized Sprague-Dawley rats of 28 weeks age were used. A 1 mm diameter and 8 mm long defect was created in the femoral neck by drilling from the lateral cortex in the axis of the femoral neck leaving the surrounding cortex intact. Three treatment groups and one control group were used 1) CS/HA alone, 2) CS/HA+ ZA (10 μg) 3) CS/HA+ZA (10 μg)+rhBMP-2 (4 μg) and 4) Empty defect. The bone formation was assessed at 4 weeks post-surgery using in vivo micro computed tomography (micro-CT). At 8 weeks post-surgery, the animals were sacrificed and both defect and contralateral femurs were subjected to micro-CT, mechanical testing and histology. Micro-CT results showed that the combination of CS/HA with ZA or ZA+rhBMP-2 increased the bone formation in the defect when compared to the other groups and to the contralateral hips. Evidence of new dense bone formation in CS/HA+ZA and CS/HA+ZA+rhBMP-2 groups was seen histologically. Mechanical testing results showed no differences in the load to fracture between the treatments in either of the treated or contralateral legs. The CS/HA biomaterial can be used as a carrier for ZA and rhBMP-2 to regenerate bone in the femoral neck canal of osteoporotic rats.
Atila, Alptug; Halici, Zekai; Cadirci, Elif; Karakus, Emre; Palabiyik, Saziye Sezin; Ay, Nuran; Bakan, Feray; Yilmaz, Sahin
2016-01-01
Boron and its derivatives are effective in bone recovery and osteointegration. However, increasing the boron levels in body liquids may cause toxicity. The aim of our study is to investigate serum boron levels using ICP-MS after implantation of different ratios of nano-hBN-HA composites in rat femurs. All rats were (n=126) divided into five experimental groups (n=24) and one healthy group (6 rats); healthy (Group1), femoral defect + %100 HA (Group2), femoral defect + %2.5 hBN + %97.5 HA (Group3), femoral defect + %5 hBN + %95 HA (Group4), femoral defect + %10 hBN + %90 HA (Group5), femoral defect + %100 hBN (Group6). The femoral defect was created in the distal femur (3mm drill-bit). Each implant group was divided into four different groups (n=24) also 6 rats sacrificed for each groups in one week intervals during four weeks. In our results; at 1, 2, 3, and 4 weeks after implantation near bone tissue, serum levels of boron were evaluated using ICP-MS. We demonstrated that neither short-term nor long-term implantation of hBN-HA composite resulted in statistically increased serum boron levels in experimental groups compared to healthy group. In conclusion, this study investigated the implant material produced form hBN-HA for the first time. Our data suggest that hBN is a new promising target for biomaterial and implant bioengineers. Copyright © 2015 Elsevier B.V. All rights reserved.
[Recent advances in treatment of aseptic femoral shaft nonunion].
Zhang, Wei; Chen, Hua; Tang, Peifu
2018-05-01
To review the recent advances in treatment of aseptic femoral shaft nonunion. The clinical studies about the treatments of aseptic femoral shaft nonunion in recent years were widely reviewed and analyzed. There are several surgical methods for aseptic femoral shaft nonunion. Due to uncertain clinical outcome, dynamization of nail should be carefully selected. The exchange nailing is suitable for the hypertrophic nonunion of the isthmal femoral shaft fracture. The exchange lateral plating is suitable for nonunion with obvious malformation. However, wave plate or dual plate should be chosen when the bone nonuinon is combined with the medial defect. The augmentation plating improves the success rate of nailing for femoral shaft nonunion, but it should be carefully selected for patients with obvious deformity or bone defect. Ilizarov technique is suitable for various bone nonunion, especially with complicated or large segmental bone defects. Induced membrane technique is also an important method for the treatment of bone nonunion with large bone defects. The clinical efficacy of the blocking screw remains to be supported by further evidence. Biological stimulants are mainly used for atrophic nonunion, and the clinical efficacy of them alone are still controversial. Due to lack of comparative studies between different surgical methods, the orthopedist should choose the appropriate treatment according to the individual situations of the patient and the types of bone nonunion.
How to deal with penile carcinoma inguinal metastases invading femoral vessels.
Fodor, Marius; Petrut, Bogdan; Fodor, Lucian
2017-01-01
Penile cancer accounts for 1-10% of men neoplastic diseases and 30-60% of patients have inguinal metastases at the time of diagnosis. Inguinal metastases of penile cancer with femoral vessel involvement could lead to vascular fistula and hemorrhagic shock. We present 3 consecutive patients with inguinal metastases of penile cancer complicated by infection and hemorrhage from femoral vessels invaded by the tumor. Simultaneous extra-anatomical axillo-femoral bypass graft, wide excision of tumor and groin defect reconstruction was used to achieve "tumor-free" oncologic aim and to save the lower limb. We consider the extra-anatomic axillo-femoral bypass associated with wide inguinal tumor excision and defect covering a feasible surgical solution for improving the life quality and extend life expectancy in patients with lymph node metastasis of penile cancer complicated by necrosis, infection and femoral vessel involvement.
Han, Sangwon; Oh, Minyoung; Yoon, Seokho; Kim, Jinsoo; Kim, Ji-Wan; Chang, Jae-Suk; Ryu, Jin-Sook
2017-03-01
Avascular necrosis (AVN) of the femoral head is a major complication after internal fixation of a femoral neck fracture and determines the functional prognosis. We investigated postoperative bone single-photon emission computed tomography/computed tomography (SPECT/CT) for assessing the risk of femoral head AVN. We retrospectively reviewed 53 consecutive patients who underwent bone SPECT/CT within 2 weeks of internal fixation of a femoral neck fracture and follow-up serial hip radiographs over at least 12 months. Nine patients developed femoral head AVN. In 15 patients who showed normal uptake on immediate postoperative SPECT/CT, no AVN occurred, whereas 9 of 38 patients who showed cold defects of the femoral head later developed AVN. The negative predictive value of immediate postoperative SPECT/CT for AVN was 100 %, whereas the positive predictive value was 24 %. Among 38 patients with cold defects, 1 developed AVN 3 months postoperatively. A follow-up bone SPECT/CT was performed in the other 37 patients at 2-10 months postoperatively. The follow-up bone SPECT/CT revealed completely normalized femoral head uptake in 27, partially normalized uptake in 8, and persistent cold defects in 2 patients. AVN developed in 3.7 % (1/27), 62.5 % (5/8), and 100 % (2/2) of each group, respectively. According to the time point of imaging, radiotracer uptake patterns of the femoral head on postoperative bone SPECT/CT indicate the risk of AVN after internal fixation of femoral neck fractures differently. Postoperative bone SPECT/CT may help orthopedic surgeons determine the appropriate follow-up of these patients.
How to deal with penile carcinoma inguinal metastases invading femoral vessels
FODOR, MARIUS; PETRUT, BOGDAN; FODOR, LUCIAN
2017-01-01
Penile cancer accounts for 1–10% of men neoplastic diseases and 30–60% of patients have inguinal metastases at the time of diagnosis. Inguinal metastases of penile cancer with femoral vessel involvement could lead to vascular fistula and hemorrhagic shock. We present 3 consecutive patients with inguinal metastases of penile cancer complicated by infection and hemorrhage from femoral vessels invaded by the tumor. Simultaneous extra-anatomical axillo-femoral bypass graft, wide excision of tumor and groin defect reconstruction was used to achieve “tumor-free” oncologic aim and to save the lower limb. We consider the extra-anatomic axillo-femoral bypass associated with wide inguinal tumor excision and defect covering a feasible surgical solution for improving the life quality and extend life expectancy in patients with lymph node metastasis of penile cancer complicated by necrosis, infection and femoral vessel involvement. PMID:29151798
A-Frame free Vascularized Fibular Graft and Femoral Lengthening for Osteosarcoma Pediatric Patients.
Cashin, Megan; Coombs, Christopher; Torode, Ian
2018-02-01
Pediatric limb reconstruction after resection of a malignant tumor presents specific challenges. Multiple surgical techniques have been used to treat these patients. This paper describes a staged surgical technique for the reconstruction of large distal femoral defects due to tumor resection in skeletally immature patients. Three pediatric patients with osteosarcoma of the distal femur underwent staged reconstruction. Neoadjuvant chemotherapy was followed by en bloc tumor resection and immediate reconstruction of the distal femoral defect with a vascularized free fibular autograft utilizing a unique A-frame construct combined with intramedullary nail fixation. The second stage was a planned gradual lengthening of the healed construct, over a custom-made magnetically driven expandable intramedullary nail. All patients achieved bony union and satisfactory length with minimal complications. The patients all returned to full, unlimited physical activities. The early results confirm that the described technique is a safe and reliable procedure for the reconstruction of large femoral defects in pediatric patients with osteosarcoma. Level IV-therapeutic.
Butera, Gianfranco; Lovin, Nicusor; Basile, Domenica Paola
2017-01-01
Secundum atrial septum defect (ASD) is the most common congenital heart disease. It is usually treated by a transcatheter approach using a femoral venous access. In case of bilateral femoral vein occlusion, the internal jugular venous approach for ASD closure is an option, in particular in cases where ASD balloon occlusion test and sizing is needed. Here, we report on a new technique for ASD closure using a venous-arterial circuit from the right internal jugular vein to the femoral artery. Two patients (females, 4 and 10 years of age) had occlusion of both femoral veins because of a previous history of pulmonary atresia and intact ventricular septum, for which they underwent percutaneous radiofrequency perforation and balloon angioplasty. These subjects needed balloon occlusion test of a residual ASD to size the hole and to check for hemodynamic suitability to ASD closure. After performing a venous-arterial circuit, a 24 mm St Jude ASD sizing balloon catheter was advanced over the circuit and the defect closed for 15 min to check hemodynamics and size the defect. ASD was closed is hemodinamically suitable. This technique was safe and reliable. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Yokota, Masashi; Yasuda, Kazunori; Kitamura, Nobuto; Arakaki, Kazunobu; Onodera, Shin; Kurokawa, Takayuki; Gong, Jian-Ping
2011-02-22
Functional repair of articular osteochondral defects remains a major challenge not only in the field of knee surgery but also in tissue regeneration medicine. The purpose is to clarify whether the spontaneous hyaline cartilage regeneration can be induced in a large osteochondral defect created in the femoral condyle by means of implanting a novel double-network (DN) gel at the bottom of the defect. Twenty-five mature rabbits were used in this study. In the bilateral knees of each animal, we created an osteochondral defect having a diameter of 2.4-mm in the medial condyle. Then, in 21 rabbits, we implanted a DN gel plug into a right knee defect so that a vacant space of 1.5-mm depth (in Group I), 2.5-mm depth (in Group II), or 3.5-mm depth (in Group III) was left. In the left knee, we did not apply any treatment to the defect to obtain the control data. All the rabbits were sacrificed at 4 weeks, and the gross and histological evaluations were performed. The remaining 4 rabbits underwent the same treatment as used in Group II, and real-time PCR analysis was performed at 4 weeks. The defect in Group II was filled with a sufficient volume of the hyaline cartilage tissue rich in proteoglycan and type-2 collagen. The Wayne's gross appearance and histology scores showed that Group II was significantly greater than Group I, III, and Control (p < 0.012). The relative expression level of type-2 collagen, aggrecan, and SOX9 mRNAs was significantly greater in Group II than in the control group (p < 0.023). This study demonstrated that spontaneous hyaline cartilage regeneration can be induced in vivo in an osteochondral defect created in the femoral condyle by means of implanting the DN gel plug at the bottom of the defect so that an approximately 2-mm deep vacant space was intentionally left in the defect. This fact has prompted us to propose an innovative strategy without cell culture to repair osteochondral lesions in the femoral condyle.
Mechanical evaluation of anastomotic tension and patency in arteries.
Zhang, F; Lineaweaver, W C; Buntic, R; Walker, R
1996-02-01
This study quantified arterial anastomotic tension, evaluated subsequent patency rates, and examined the degree of tension reduction with vessel mobilization. The study was divided into two components. In part I, a mechanical analysis was undertaken to evaluate tension, based on the determination of the force required to deflect a cable (vessel) laterally, and its resulting lateral displacement. Six Sprague-Dawley rats with 12 femoral arteries were divided into two subgroups: 1) no mobilization; and 2) axial mobilization by ligation and transection of superficial epigastric and gracilis muscular branches. The tension of femoral arterial anastomoses was calculated in vessels with no segmental defect and with 1.5-, 3-, 4.5-, 6-, and 7.5-mm defects. In part II, patency was evaluated. Fifty-five rats with 110 femoral arteries were divided into two sub-groups as defined in part I: 1) no mobilization; and 2) axial mobilization by ligation and transection of superficial epigastric and gracilis muscular branches. Microvascular anastomoses were performed with no segmental defect and with 1-, 2-, 3-, 4-, 5-, 6-, 7-, 8-, 9-, and 10-mm segmental vessel defects. Patency was evaluated 24 hr postoperatively. Part I of the study revealed that anastomotic tension gradually increased along with an increase in the length of the vessel defect, from 1.9 to 11.34 g in the no-mobilization group and from 1.97 to 8.44 g in the axial-mobilization group. Comparison of tension linear regression coefficient showed a significant difference between the two groups (p < 0.05). In part II of the study, the maximum length of femoral artery defects still able to maintain 100 percent patency of anastomoses was 4 mm (tension approximately 6 g) in the no-mobilization group and 6 mm in the axial-mobilization group (tension approximately 6.48 g). Microanastomotic tension was related to the size of the vessel defect, with increasing tension leading to thrombosis. Axial mobilization significantly reduced the tension in vessels with segmental defects and decreased thrombosis rates.
Heinecke, Markus; Rathje, Fabian; Layher, Frank; Matziolis, Georg
2018-05-01
Although cementless revision arthroplasty of the hip has become the gold standard, revision arthroplasty of the distal femur is controversial. This study evaluated the anchoring principles of different femoral revision stem designs in extended bone defect situations, taking into account the anatomical conditions of the proximal and distal femur, and the resulting primary stability. Cementless press-fit stems of 4 different designs were implanted in synthetic femurs. The specimens were analyzed by computed tomography and were tested considering axial/torsional stiffness and migration resistance. Different stem designs anchored in different femoral canal geometries achieved comparable primary stability. Despite considerably different anchorage lengths, no difference in migration behavior or stiffness was found. Both in the distal femur and in the proximal femur, the conical stems showed a combination of conical and 3-point anchorage. Regarding the cylindrical stem tested, a much shorter anchorage length was sufficient in the distal femur to achieve comparable primary stability. In the investigated osseous defect model, the stem design (conical vs cylindrical), not the geometry of the femoral canal (proximal vs distal), was decisive regarding the circumferential anchorage length. For the conical stems, it can be postulated that there are reserves available for achieving a conical-circular fixation as a result of the large contact length. For the cylindrical stems, only a small reserve for a stable anchorage can be assumed. [Orthopedics. 2018; 41(3):e369-e375.]. Copyright 2018, SLACK Incorporated.
Skelly, Jordan D; Lange, Jeffrey; Filion, Tera M; Li, Xinning; Ayers, David C; Song, Jie
2014-12-01
Bone grafts simultaneously delivering therapeutic proteins and antibiotics may be valuable in orthopaedic trauma care. Previously, we developed a poly(2-hydroxyethyl methacrylate)-nanocrystalline hydroxyapatite (pHEMA-nHA) synthetic bone graft that, when preabsorbed with 400-ng rhBMP-2/7, facilitated the functional repair of critical-size rat femoral defects. Recently, we showed that pHEMA-nHA effectively retains/releases vancomycin and rhBMP-2 in vitro. The success of such a strategy requires that the incorporation of vancomycin does not compromise the structural integrity of the graft nor its ability to promote bone healing. (1) To evaluate the ability of pHEMA-nHA-vancomycin composites in combination with 3-µg rhBMP-2 to repair 5 mm rat femoral segmental defects, and (2) To determine if the encapsulated vancomycin impairs the graft/rhBMP-2-assisted bone repair. pHEMA-nHA-vancomycin, pHEMA-nHA, or collagen sponge control with/without 3-µg rhBMP-2 were press-fit in 5 mm femoral defects in SASCO-SD male rats (289-300 g). Histology, microcomputed tomography, and torsion testing were performed on 8- and 12-week explants to evaluate the extent and quality of repair. The effect of vancomycin on the temporal absorption of endogenous BMP-2 and stromal cell-derived factor-1 was evaluated by immunohistochemistry. These factors are important for bone healing initiation and stem cell recruitment, respectively. Partial bridging of the defect with bony callus by 12 weeks was observed with pHEMA-nHA-vancomycin without rhBMP-2 while full bridging with substantially mineralized callus and partial restoration of torsional strength was achieved with 3-µg rhBMP-2. The presence of vancomycin changed the absorption patterns of endogenous proteins on the grafts, but did not appear to substantially compromise graft healing. The composite pHEMA-nHA-vancomycin preabsorbed with 3-µg rhBMP-2 promoted repair of 5 mm rat femoral segmental defects. With the sample sizes applied, vancomycin encapsulation did not appear to have a negative effect on bone healing. pHEMA-nHA-vancomycin preabsorbed with rhBMP-2 may be useful in the repair of critical-size long bone defects prone to infections.
Arthroscopic retrograde osteochondral autologous transplantation to chondral lesion in femoral head.
Cetinkaya, Sarper; Toker, Berkin; Taser, Omer
2014-06-01
This report describes the treatment of 2 cases of full-thickness cartilage defect of the femoral head. The authors performed osteochondral autologous transplantation with a different technique that has not been reported to date. One patient was 37 years old, and the other was 42 years old. Both presented with hip pain. In both patients, radiograph and magnetic resonance imaging scan showed a focal chondral defect on the weight-bearing area of the femoral head and acetabular impingement. A retrograde osteochondral autologous transplantation technique combined with hip arthroscopy and arthroscopic impingement treatment was performed. After a 2-month recovery period, the symptoms were resolved. In the first year of follow-up, Harris Hip scores improved significantly (case 1, 56.6 to 87.6; case 2, 58.6 to 90). The technique described yielded good short- and midterm clinical and radiologic outcomes. To the authors' knowledge, this report is the first to describe a retrograde osteochondral transplantation technique performed with hip arthroscopy in the femoral head. Copyright 2014, SLACK Incorporated.
Biomimetic structured surfaces increase primary adhesion capacity of cartilage implants.
Lahner, Matthias; Kalwa, Lukas; Olbring, Roxana; Mohr, Charlotte; Göpfert, Lena; Seidl, Tobias
2015-01-01
In cartilage repair, scaffold-assisted single-step techniques are used to improve the cartilage regeneration. Nevertheless, the fixation of cartilage implants represents a challenge in orthopaedics, particularly in the moist conditions that pertain during arthroscopic surgery. Within the animal kingdom a broad range of species has developed working solutions to intermittent adhesion under challenging conditions. Using a top-down approach we identified promising mechanisms for biomimetic transfer The tree-frog adhesive system served as a test case to analyze the adhesion capacity of a polyglycolic acid (PGA) scaffold with and without a structural modification in a bovine articular cartilage defect model. To this end, PGA implants were modified with a simplified foot-pad structure and evaluated on femoral articular bovine cartilage lesions. Non-structured PGA scaffolds were used as control. Both implants were pressed on 20 mm × 20 mm full-thickness femoral cartilage defects using a dynamometer. The structured scaffolds showed a higher adhesion capacity on the cartilage defect than the non-structured original scaffolds. The results suggest that the adhesion ability can be increased by means of biomimetic structured surfaces without the need of additional chemical treatment and thus significantly facilitate primary fixation procedures.
Evaluation of Osteoconductive Scaffolds in the Canine Femoral Multi-Defect Model
Luangphakdy, Viviane; Walker, Esteban; Shinohara, Kentaro; Pan, Hui; Hefferan, Theresa; Bauer, Thomas W.; Stockdale, Linda; Saini, Sunil; Dadsetan, Mahrokh; Runge, M. Brett; Vasanji, Amit; Griffith, Linda; Yaszemski, Michael
2013-01-01
Treatment of large segmental bone defects remains an unsolved clinical challenge, despite a wide array of existing bone graft materials. This project was designed to rapidly assess and compare promising biodegradable osteoconductive scaffolds for use in the systematic development of new bone regeneration methodologies that combine scaffolds, sources of osteogenic cells, and bioactive scaffold modifications. Promising biomaterials and scaffold fabrication methods were identified in laboratories at Rutgers, MIT, Integra Life Sciences, and Mayo Clinic. Scaffolds were fabricated from various materials, including poly(L-lactide-co-glycolide) (PLGA), poly(L-lactide-co-ɛ-caprolactone) (PLCL), tyrosine-derived polycarbonate (TyrPC), and poly(propylene fumarate) (PPF). Highly porous three-dimensional (3D) scaffolds were fabricated by 3D printing, laser stereolithography, or solvent casting followed by porogen leaching. The canine femoral multi-defect model was used to systematically compare scaffold performance and enable selection of the most promising substrate(s) on which to add cell sourcing options and bioactive surface modifications. Mineralized cancellous allograft (MCA) was used to provide a comparative reference to the current clinical standard for osteoconductive scaffolds. Percent bone volume within the defect was assessed 4 weeks after implantation using both MicroCT and limited histomorphometry. Bone formed at the periphery of all scaffolds with varying levels of radial ingrowth. MCA produced a rapid and advanced stage of bone formation and remodeling throughout the defect in 4 weeks, greatly exceeding the performance of all polymer scaffolds. Two scaffold constructs, TyrPCPL/TCP and PPF4SLA/HAPLGA Dip, proved to be significantly better than alternative PLGA and PLCL scaffolds, justifying further development. MCA remains the current standard for osteoconductive scaffolds. PMID:23215980
Evaluation of osteoconductive scaffolds in the canine femoral multi-defect model.
Luangphakdy, Viviane; Walker, Esteban; Shinohara, Kentaro; Pan, Hui; Hefferan, Theresa; Bauer, Thomas W; Stockdale, Linda; Saini, Sunil; Dadsetan, Mahrokh; Runge, M Brett; Vasanji, Amit; Griffith, Linda; Yaszemski, Michael; Muschler, George F
2013-03-01
Treatment of large segmental bone defects remains an unsolved clinical challenge, despite a wide array of existing bone graft materials. This project was designed to rapidly assess and compare promising biodegradable osteoconductive scaffolds for use in the systematic development of new bone regeneration methodologies that combine scaffolds, sources of osteogenic cells, and bioactive scaffold modifications. Promising biomaterials and scaffold fabrication methods were identified in laboratories at Rutgers, MIT, Integra Life Sciences, and Mayo Clinic. Scaffolds were fabricated from various materials, including poly(L-lactide-co-glycolide) (PLGA), poly(L-lactide-co-ɛ-caprolactone) (PLCL), tyrosine-derived polycarbonate (TyrPC), and poly(propylene fumarate) (PPF). Highly porous three-dimensional (3D) scaffolds were fabricated by 3D printing, laser stereolithography, or solvent casting followed by porogen leaching. The canine femoral multi-defect model was used to systematically compare scaffold performance and enable selection of the most promising substrate(s) on which to add cell sourcing options and bioactive surface modifications. Mineralized cancellous allograft (MCA) was used to provide a comparative reference to the current clinical standard for osteoconductive scaffolds. Percent bone volume within the defect was assessed 4 weeks after implantation using both MicroCT and limited histomorphometry. Bone formed at the periphery of all scaffolds with varying levels of radial ingrowth. MCA produced a rapid and advanced stage of bone formation and remodeling throughout the defect in 4 weeks, greatly exceeding the performance of all polymer scaffolds. Two scaffold constructs, TyrPC(PL)/TCP and PPF4(SLA)/HA(PLGA) (Dip), proved to be significantly better than alternative PLGA and PLCL scaffolds, justifying further development. MCA remains the current standard for osteoconductive scaffolds.
Magnetic resonance imaging of hyaline cartilage regeneration in neocartilage graft implantation.
Tan, C F; Ng, K K; Ng, S H; Cheung, Y C
2003-12-01
The purpose of this study was to investigate the regenerative potential of hyaline cartilage in a neocartilage graft implant with the aid of MR cartilage imaging using a rabbit model. Surgical osteochondral defects were created in the femoral condyles of 30 mature New Zealand rabbits. The findings of neocartilage in autologous cartilage grafts packed into osteochondral defects were compared with control group of no implant to the osteochondral defect. The outcome of the implantations was correlated with histologic and MR cartilage imaging findings over a 3-month interval. Neocartilage grafts packed into osteochondral defects showed regeneration of hyaline cartilage at the outer layer of the implant using MR cartilage imaging. Fibrosis of fibrocartilage developed at the outer layer of the autologous cartilage graft together with an inflammatory reaction within the osteochondral defect. This animal study provides evidence of the regenerative ability of hyaline cartilage in neocartilage transplants to repair articular cartilage.
Harwin, Steven F
2007-03-01
During preparation for uncemented femoral arthroplasty, a phenomenon has been observed that indicates thinning of anterior metaphyseal bone to a critical level. Light can be seen from within the canal passing through the anterior cortex. This skylight sign alerts the surgeon that a cortical defect or fracture can occur on reaming, broaching, or component insertion. In 420 consecutive arthroplasties, a skylight sign was noted in 97 (23%) hips. In 5 of those hips an oval cortical defect was created and in 3 hips a fracture occurred during broaching or insertion. Loosening developed in 1 hip with fracture. No fractures or defects occurred in hips without a skylight sign. If a skylight sign is present, the femur is at risk and preventive measures should be taken.
Luangphakdy, V; Shinohara, K; Pan, H; Boehm, C; Samaranska, A; Muschler, G F
2015-01-12
Recombinant human bone morphogenetic protein-2, when applied to an absorbable type 1 bovine collagen sponge (rhBMP-2/ACS) is an effective therapy in many bone grafting settings. Bone marrow aspirate (BMA) has also been used as a source of transplantable osteogenic connective tissue progenitors. This study was designed to characterize the performance of a scaffold comprising rhBMP-2/ACS in which the sponge wraps around tri-calcium phosphate hydroxyapatite granules (rhBMP-2/ACS/TCP-HA) and to test the hypothesis that addition of BMA will improve the performance of this construct in the Canine Femoral Multi Defect Model. In each subject, two sites were grafted with rhBMP-2/ACS/TCP-HA scaffold loaded with BMA clot and two other sites with rhBMP-2/ACS/TCP-HA scaffold loaded with wound blood (WB). After correction for unresorbed TCP-HA granules, sites grafted with rhBMP-2/ACS/TCP-HA+BMA and rhBMP-2/ACS/TCP-HA+WB were similar, with mean percent bone volumes of 10.9 %±1.2 and 11.2 %±1.2, respectively. No differences were seen in quantitative histomorphometry. While bone formation using both constructs was robust, this study did not support the hypothesis that the addition of unprocessed bone marrow aspirate clot improved bone regeneration in a site engrafted with rhBMP-2/ACS/TCP-HA+BMA. In contrast to prior studies using this model, new bone formation was greater at the center of the defect where TCP-HA was distributed. This finding suggests a potential synergy between rhBMP-2 and the centrally placed ceramic and cellular components of the graft construct. Further optimization may also require more uniform distribution of TCP-HA, alternative cell delivery strategies, and a more rigorous large animal segmental defect model.
Hu, Zhi-ming; Wang, Hai-bin; Zhou, Ming-qian; Yao, Xin-sheng; Ma, Li; Wang, Xiao-ning
2006-06-01
To observe the pathological changes in the blood vessels in rabbit femoral head with glucocorticoid-induced necrosis and investigate the pathogenesis of glucocorticoid-induced osteonecrosis. Twenty New Zealand white rabbits were randomly divided into two groups, namely group A. which was injected with horse serum and prednisone and group B as the control group. Chinese ink was injected into the femoral cavity of the rabbits to observe the blood vessels in the femoral head under optical microscope and the femoral head was examined histopathologically. Compared with the normal control group, the rabbits in group A had significantly decreased number of perfused vessels, which was featured by defective perfusion, osteocytie pyknosis or necrosis, increase of empty ostoocyte lacunae and fat cells, decrease of hematopoietic tissue, and blood vessel occlusion. Vascular occlusion and vasculitis due to glucocorticoid treatment may cause avascular necrosis of the femoral head.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bargar, W.L.; Paul, H.A.; Merritt, K.
1986-01-01
A canine model was developed to investigate the use of an autogeneic iliac bone graft to treat the calcar deficiency commonly found at the time of revision surgery for femoral component loosening. Five large male mixed-breed dogs had bilateral total hip arthroplasty staged at three-month intervals, and were sacrificed at six months. Prior to cementing the femoral component, an experimental calcar defect was made, and a bicortical iliac bone graft was fashioned to fill the defect. Serial roentgenograms showed the grafts had united with no resorption. Technetium-99 bone scans showed more uptake at three months than at six months inmore » the graft region. Disulfine blue injection indicated all grafts were perfused at both three and six months. Thin section histology, fluorochromes, and microradiographs confirmed graft viability in all dogs. Semiquantitative grading of the fluorochromes indicated new bone deposition in 20%-50% of each graft at three months and 50%-80% at six months. Although the calcar bone graft was uniformly successful in this canine study, the clinical application of this technique should be evaluated by long-term results in humans.« less
2011-01-01
Background Femoral offset influences the forces at the hip and the implant stresses after revision THR. For extended bone defects, these forces may cause considerable bending moments within the implant, possibly leading to implant failure. This study investigates the influences of femoral anteversion and offset on stresses in the Wagner SL revision stem implant under varying extents of bone defect conditions. Methods Wagner SL revision stems with standard (34 mm) and increased offset (44 mm) were virtually implanted in a model femur with bone defects of variable extent (Paprosky I to IIIb). Variations in surgical technique were simulated by implanting the stems each at 4° or 14° of anteversion. Muscle and joint contact forces were applied to the reconstruction and implant stresses were determined using finite element analyses. Results Whilst increasing the implant's offset by 10 mm led to increased implant stresses (16.7% in peak tensile stresses), altering anteversion played a lesser role (5%). Generally, larger stresses were observed with reduced bone support: implant stresses increased by as much as 59% for a type IIIb defect. With increased offset, the maximum tensile stress was 225 MPa. Conclusion Although increased stresses were observed within the stem with larger offset and increased anteversion, these findings indicate that restoration of offset, key to restoring joint function, is unlikely to result in excessive implant stresses under routine activities if appropriate fixation can be achieved. PMID:21569522
Femoral-facial syndrome with malformations in the central nervous system.
Leal, Evelia; Macías-Gómez, Nelly; Rodríguez, Lisa; Mercado, F Miguel; Barros-Núñez, Patricio
2003-01-01
The femoral hypoplasia-unusual facies syndrome (FFS) is a very rare association of femoral and facial abnormalities. Maternal diabetes mellitus has been mainly involved as the causal agent. We report the second case of FFS with anomalies in the central nervous system (CNS) including corticosubcortical atrophy, colpocephaly, partial agenesis of corpus callosum, hypoplasia of the falx cerebri and absent septum pellucidum. The psychomotor development has been normal. We propose that the CNS defects observed in these patients are part of the spectrum of abnormalities in the FFS.
Liodakis, Emmanouil; Kenawey, Mohamed; Krettek, Christian; Ettinger, Max; Jagodzinski, Michael; Hankemeier, Stefan
2011-02-01
The long-term outcomes following femoral and tibial segment transports are not well documented. Purpose of the study is to compare the complication rates and life quality scores of femoral and tibial transports in order to find what are the complication rates of femoral and tibial monorail bone transports and if they are different? We retrospectively analyzed the medical records of 8 femoral and 14 tibial consecutive segment transports performed with the monorail technique between 2001 and 2008 in our institution. Mean follow-up was 5.1 ± 2.1 years with a minimum follow-up of 2 years. Aetiology of the defects was posttraumatic in all cases. Four femoral (50%) and nine tibial (64%) fractures were open. The Short Form-36 (SF-36) health survey was used to compare the life quality after femoral and tibial bone transports. The Mann-Whiney U test, Fisher exact test, and the Student's two tailed t-test were used for statistical analysis. P ≤ 0.05 was considered to be statistically significant. The tibial transport was associated with higher rates of severe complications and additional procedures (1.5 ± 0.9 vs. 3.4 ± 2.7, p = 0.048). Three patients of the tibial group were amputated because of recurrent infections and one developed a complete regenerate insufficiency that was treated with partial diaphyseal tibial replacement. Contrary to that none of patients of the femoral group developed a complete regenerate insufficiency or was amputated. Tibial bone transports have a higher rate of complete and incomplete regenerate insufficiency and can more often end in an amputation. The authors suggest systematic weekly controls of the CRP value and of the callus formation in patients with posttraumatic tibia bone transports. Further comparative studies comparing the results of bone transports with and without intramedullary implants are necessary.
Mastrokalos, Dimitrios S; Panagopoulos, Georgios N; Galanopoulos, Ioannis P; Papagelopoulos, Panayiotis J
2017-10-01
Management of a posterior shoulder dislocation with an associated reverse Hill-Sachs lesion is challenging, both diagnostically and therapeutically. Diagnosis is frequently delayed or missed, whereas the resulting humeral head defect is often larger and more difficult to salvage than in anterior shoulder dislocations. This report presents the case of a 29-year-old male with a recurrent posterior shoulder dislocation associated with a large reverse Hill-Sachs defect, treated with bone augmentation of the lesion with a combination of fresh femoral head allograft and a locally harvested humeral head autograft transfer, with a successful outcome. Level of evidence V.
2013-01-01
Introduction Free vascularized fibular grafts have been widely used for the reconstruction of long bone defects. However, the use of a vascularized tibial graft is precluded by its weight-bearing function and unacceptable donor site morbidity. Case presentation We present a rare case of using a vascularized tibia-fibular composite graft taken from a 6-year-old Chinese boy’s ipsilateral lower leg to reconstruct a large bony defect of his traumatic femur. Hypertrophy of the tibial graft, good remodeling of the femoral shaft, and atrophy of the unloaded fibular graft were noted at the 10-year follow up. He was able to participate in outdoor activities such as basketball while wearing his prosthesis. Conclusions The 10-year follow up demonstrates the feasibility of this salvage procedure for a floating knee injury with neurovascular compromise. PMID:23714102
Tomić, S; Krajcinović, O; Blagojević, Z; Apostolović, M; Lalosević, V
2006-01-01
We analyzed 30 patients with infected diaphyseal defect of femur, which have been treated by lengthening one of the bone fragments with Ilizarov apparatus. The mean length of the bone defect was 6 cm. Substitution of the defect, bone healing and elimination of the infection was achieved in 27 patients. The mean time of apparatus fixation was 10 months. According to Palley scoring system, 10 patients had excellent functional results.
Eingartner, Christoph; Volkmann, Rüdiger; Ochs, Uwe; Egetemeyr, Daniel; Weise, Kuno
2007-10-01
Healing of the periprosthetic fracture and area of defective bone by the bone healing mechanisms of intramedullary stabilization. Reconstruction of the correct length, axial alignment, and rotation of the fractured femoral shaft by anchoring a revision stem in the intact femoral diaphysis. Periprosthetic femoral shaft fracture in the region of the prosthetic stem combined with preexistent loosening and/or defect in the periprosthetic bone bed (Vancouver classification type B2 and B3). General contraindications, local infection. Lateral transmuscular approach to the femoral shaft. Longitudinal osteotomy of the proximal femur taking the geometry of the fracture into account. Opening of an anterior "bone shell". Removal of the loose prosthetic stem and cement. Debridement. Preparation of the femoral diaphysis and insertion of a distally anchored revision stem. Distal locking. Repositioning of the "bone shell", reduction of the fracture, and retention with cerclage wires. Bed rest for approximately 1 week, mobilization with 20 kg partial weight bearing for 12 weeks, gradual increase in weight bearing with radiologic checks on progress, removal of the distal locking bolts after 12-24 months at the earliest. 21 patients (13 women, eight men) aged between 43 and 86 years (mean age: 71.2 years) with periprosthetic fracture of the femur, additional loosening of the stem in eight cases (Vancouver B2) and additional bone loss in 13 cases (Vancouver B3). Postoperative complications: two fractures following another fall (repeat operations: one replacement, one plate), four revisions due to subsidence of the stem (three replacements involving change to a standard stem with healed proximal femur, one replacement with another interlocked revision stem). Bone healing occurred for all fractures after a mean 5.6 months (3-11 months). Follow- up examination after a mean 4.5 years: all patients were able to walk, average Harris Score 70.5 points (29- 95 points).
Eingartner, Christoph; Volkmann, Rüdiger; Ochs, Uwe; Egetemeyr, Daniel; Weise, Kuno
2006-10-01
Healing of the periprosthetic fracture and area of defective bone by the bone healing mechanisms of intramedullary stabilization. Reconstruction of the correct length, axial alignment, and rotation of the fractured femoral shaft by anchoring a revision stem in the intact femoral diaphysis. Periprosthetic femoral shaft fracture in the region of the prosthetic stem combined with preexistent loosening and/or defect in the periprosthetic bone bed (Vancouver classification type B2 and B3). General contraindications, local infection. Lateral transmuscular approach to the femoral shaft. Longitudinal osteotomy of the proximal femur taking the geometry of the fracture into account. Opening of an anterior "bone shell". Removal of the loose prosthetic stem and cement. Debridement. Preparation of the femoral diaphysis and insertion of a distally anchored revision stem. Distal locking. Repositioning of the "bone shell", reduction of the fracture, and retention with cerclage wires. Bed rest for approximately 1 week, mobilization with 20 kg partial weight bearing for 12 weeks, gradual increase in weight bearing with radiologic checks on progress, removal of the distal locking bolts after 12-24 months at the earliest. 21 patients (13 women, eight men) aged between 43 and 86 years (mean age: 71.2 years) with periprosthetic fracture of the femur, additional loosening of the stem in eight cases (Vancouver B2) and additional bone loss in 13 cases (Vancouver B3). Postoperative complications: two fractures following another fall (repeat operations: one replacement, one plate), four revisions due to subsidence of the stem (three replacements involving change to a standard stem with healed proximal femur, one replacement with another interlocked revision stem). Bone healing occurred for all fractures after a mean 5.6 months (3-11 months). Follow-up examination after a mean 4.5 years: all patients were able to walk, average Harris Score 70.5 points (29-95 points).
Won, Yougun; Lee, Gi Soo; Kim, Sang Bum; Kim, Sun Joong; Yang, Kyu Hyun
2016-11-01
As anatomical reduction of the articular surface of femoral head fractures and restoration of damaged cartilage are essential for good long-term results, many treatment options have been suggested, including fixation of the fracture using various surgical exposures and implants, as well as arthroscopic irrigation and debridement, bone marrow stimulating techniques, osteochondral allograft, autograft, and autogenous chondrocyte implantation. We report a case of osteochondral autograft harvested from its own femoral articular surface through surgical hip dislocation. The osteochondral graft was harvested from the inferior non-weight-bearing articular surface and grafted to the osteochondral defect. One year later, the clinical and radiological results were good, without the collapse of the femoral head or arthritic change. This procedure introduced in our case is considered convenient and able to lessen surgical time without morbidity of the donor site associated with the harvest.
Hoemann, Caroline D; Hurtig, Mark; Rossomacha, Evgeny; Sun, Jun; Chevrier, Anik; Shive, Matthew S; Buschmann, Michael D
2005-12-01
Microfracture is a surgical procedure that is used to treat focal articular cartilage defects. Although joint function improves following microfracture, the procedure elicits incomplete repair. As blood clot formation in the microfracture defect is an essential initiating event in microfracture therapy, we hypothesized that the repair would be improved if the microfracture defect were filled with a blood clot that was stabilized by the incorporation of a thrombogenic and adhesive polymer, specifically, chitosan. The objectives of the present study were to evaluate (1) blood clot adhesion in fresh microfracture defects and (2) the quality of the repair, at six months postoperatively, of microfracture defects that had been treated with or without chitosan-glycerol phosphate/blood clot implants, using a sheep model. In eighteen sheep, two 1-cm2 full-thickness chondral defects were created in the distal part of the femur and treated with microfracture; one defect was made in the medial femoral condyle, and the other defect was made in the trochlea. In four sheep, microfracture defects were created bilaterally; the microfracture defects in one knee received no further treatment, and the microfracture defects in the contralateral knee were filled with chitosan-glycerol phosphate/autologous whole blood and the implants were allowed to solidify. Fresh defects in these four sheep were collected at one hour postoperatively to compare the retention of the chitosan-glycerol phosphate/blood clot with that of the normal clot and to define the histologic characteristics of these fresh defects. In the other fourteen sheep, microfracture defects were made in only one knee and either were left untreated (control group; six sheep) or were treated with chitosan-glycerol phosphate/blood implant (treatment group; eight sheep), and the quality of repair was assessed histologically, histomorphometrically, and biochemically at six months postoperatively. In the defects that were examined one hour postoperatively, chitosan-glycerol phosphate/blood clots showed increased adhesion to the walls of the defects as compared with the blood clots in the untreated microfracture defects. After histological processing, all blood clots in the control microfracture defects had been lost, whereas chitosanglycerol phosphate/blood clot adhered to and was partly retained on the surfaces of the defect. At six months, defects that had been treated with chitosan-glycerol phosphate/blood were filled with significantly more hyaline repair tissue (p < 0.05) compared with control defects. Repair tissue from medial femoral condyle defects that had been treated with chitosan-glycerol phosphate/blood contained more cells and more collagen compared with control defects and showed complete restoration of glycosaminoglycan levels. Solidification of a chitosan-glycerol phosphate/blood implant in microfracture defects improved cartilage repair compared with microfracture alone by increasing the amount of tissue and improving its biochemical composition and cellular organization.
Dong, Jingjing; Cui, Geng; Bi, Long; Li, Jie; Lei, Wei
2013-01-01
In order to improve the mechanical and biological properties of calcium phosphate cement (CPC, nanometer-biomaterial) for bone reconstruction in the rabbit femoral defect model, fibrin glue (FG, the natural product, purified from the blood) was introduced at three different ratios. The CPC powder and the FG solution were mixed, respectively, at the powder/liquid (P/L) ratios (g/mL) of 1:1, 3:1, and 5:1 (g/mL), and pure CPC was used as a control. After being implanted into the femoral defect in rabbit, the healing process was evaluated by micro-computed tomography scan, biomechanical testing, and histological examination. By micro-computed tomography analysis, the P/L ratio of 1:1 (g/mL) group indicated the largest quantity of new bone formation at 4 weeks, 8 weeks, and 12 weeks after implantation, respectively. Bone volume per trabecular volume of the 1:1 group was highest in the four groups, which was 1.45% ± 0.42%, 7.35% ± 1.45%, and 29.10% ± 1.67% at 4 weeks, 8 weeks, and 12 weeks after the operation, respectively. In the biomechanical tests, the compressive strength and the elastic modulus of the three CPC–FG groups were much higher than those of the pure CPC group at the determined time point (P < 0.05). The histological evaluation also showed the best osseointegration in the 1:1 group at 4 weeks, 8 weeks, and 12 weeks after the operation, respectively. In the 1:1 group, the bone grew into the pore of the cement in the laminar arrangement and connected with the cement tightly at the 12th week after the operation. This present study indicated that the CPC–FG composite at the P/L ratio of 1:1 (g/mL) stimulated bone regeneration better than any other designed group, which suggested that CPC–FG at the P/L ratio of 1:1 has significant potential as the bioactive material for the treatment of bone defects. PMID:23576869
He, Fupo; Chen, Yan; Li, Jiyan; Lin, Bomiao; Ouyang, Yi; Yu, Bo; Xia, Yuanyou; Yu, Bo; Ye, Jiandong
2015-04-01
In this study, a platelet-rich plasma poly(lactic-co-glycolic acid) (PRP-PLGA)/calcium phosphate cement (CPC) composite scaffold was prepared by incorporating PRP into PLGA/CPC scaffold with unidirectional pore structure, which was fabricated by the unidirectional freeze casting of CPC slurry and the following infiltration of PLGA. The results from in vitro cell experiments and in vivo implantation in femoral defects manifested that incorporation of PRP into PLGA/CPC scaffold improved in vitro cell response (cell attachment, proliferation, and differentiation), and markedly boosted bone formation, angiogenesis and material degradation. The incorporation of PRP into scaffold showed more outstanding improvement in osteogenesis as the scaffolds were used to repair the segmental radial defects, especially at the early stage. The new bone tissues grew along the unidirectional lamellar pores of scaffold. At 12 weeks postimplantation, the segmental radial defects treated with PRP-PLGA/CPC scaffold had almost recuperated, whereas treated with the scaffold without PRP was far from healed. Taken together, the PRP-PLGA/CPC scaffold with unidirectional pore structure is a promising candidate to repair bone defects at various sites. © 2014 Wiley Periodicals, Inc.
Brimmo, Olubusola A; Bozynski, Chantelle C; Cook, Cristi R; Kuroki, Keiichi; Sherman, Seth L; Pfeiffer, Ferris M; Stoker, Aaron M; Cook, James L
2018-05-10
This study characterizes long-term outcomes associated with subchondroplasty (SCP) treatment for impact-induced subchondral bone marrow lesions (BML) using a validated pre-clinical canine model. With IACUC approval, purpose-bred research hounds (n = 16) underwent arthroscopic impact injury (40N) to both medial femoral condyles. At 3 months, functional assessments, arthroscopy and MRI were performed and knees (n = 32) were randomly assigned to SCP (3 mL fluoroscopically guided percutaneous injection of AccuFill BSM into BML bone defects) or sham injection (Control). Dogs were assessed at 3, 6, 12, and 24 months after treatment using functional assessments, radiographic evaluation, arthroscopy, and MRI. Dogs were humanely euthanatized at 3, 6, 12, or 24 months after treatment for gross, microCT, and histologic assessments. All knees had focal articular cartilage defects with associated subchondral BMLs, as well as clinical dysfunction, 3 months after injury. At the 3- and 6-months, SCP knees showed more functional impairment than Control knees, however, these differences were not statistically significant. At 1 and 2 years post-treatment, function in SCP knees was better than in Control knees with range of motion being significantly (p < 0.05) better for SCP. Radiographic, arthroscopic, MRI, gross, microCT, and histologic findings matched the functional assessments well with Control being associated with better results at the 2 early time points and SCP being associated with better results at 1 and 2 years. SCP treatment using calcium phosphate bone void filler was associated with an initial increase in pain and dysfunction followed by symptomatic benefits for up to 2 years after treatment for post-traumatic femoral condyle BMLs in a preclinical canine model. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Chondral defect repair after the microfracture procedure: a nonhuman primate model.
Gill, Thomas J; McCulloch, Patrick C; Glasson, Sonya S; Blanchet, Tracey; Morris, Elizabeth A
2005-05-01
The extent and time course of chondral defect healing after microfracture in humans are not well described. Although most physicians recommend a period of activity and weightbearing restriction to protect the healing cartilage, there are limited data on which to base decisions regarding the duration of such restrictions. Evaluation of the status of chondral defect repair at different time points after microfracture in a primate model may provide a rationale for postoperative activity recommendations. Descriptive laboratory study. Full-thickness chondral defects created on the femoral condyles and trochlea of 12 cynomolgus macaques were treated with microfracture and evaluated by gross and histologic examination at 6 and 12 weeks. At 6 weeks, there was limited chondral repair and ongoing resorption of subchondral bone. By 12 weeks, the defects were completely filled and showed more mature cartilage and bone repair. In the primate animal model, significant improvements in the extent and quality of cartilage repair were observed from the 6- to 12-week time points after microfracture. The poor status of the defect repair at 6 weeks and the ongoing healing observed from the 6- to 12-week time points may indicate that the repair is vulnerable during this initial postoperative period. Assuming the goal of postoperative weightbearing and activity restriction in patients after microfracture is to protect immature repair tissue, this study lends support to extending such recommendations longer than 6 weeks.
Calomme, M; Geusens, P; Demeester, N; Behets, G J; D'Haese, P; Sindambiwe, J B; Van Hoof, V; Vanden Berghe, D
2006-04-01
Silicon (Si) deficiency in animals results in bone defects. Choline-stabilized orthosilicic acid (ch-OSA) was found to have a high bioavailability compared to other Si supplements. The effect of ch-OSA supplementation was investigated on bone loss in aged ovariectomized (OVX) rats. Female Wistar rats (n = 58, age 9 months) were randomized in three groups. One group was sham-operated (sham, n = 21), and bilateral OVX was performed in the other two groups. OVX rats were supplemented orally with ch-OSA over 30 weeks (OVX1, n = 20; 1 mg Si/kg body weight daily) or used as controls (OVX0, n = 17). The serum Si concentration and the 24-hour urinary Si excretion of supplemented OVX rats was significantly higher compared to sham and OVX controls. Supplementation with ch-OSA significantly but partially reversed the decrease in Ca excretion, which was observed after OVX. The increase in bone turnover in OVX rats tended to be reduced by ch-OSA supplementation. ch-OSA supplementation increased significantly the femoral bone mineral content (BMC) in the distal region and total femoral BMC in OVX rats, whereas lumbar BMC was marginally increased. Femoral BMD was significantly increased at two sites in the distal region in OVX rats supplemented with ch-OSA compared to OVX controls. Total lumbar bone mineral density was marginally increased by ch-OSA supplementation. In conclusion, ch-OSA supplementation partially prevents femoral bone loss in the aged OVX rat model.
2010-04-09
polymethylmethacrylate bead implan- tation to conventional parenteral antibiotic therapy in infected total hip and knee arthroplasty, Clin. Orthop. Relat...Anger, J.A. Cobos, J.T. Mader, The treatment of infected nonunions with gentamicin- polymethylmethacrylate antibiotic beads, Clin. Orthop. Relat. Res...impregnated polymethylmethacrylate beads, Clin. Orthop. Relat. Res. (1992) 244–252. [12] D.K. Kuechle, G.C. Landon, D.M. Musher, P.C. Noble, Elution of
Porous CaP/silk composite scaffolds to repair femur defects in an osteoporotic model
Cheng, Ning; Dai, Jing; Cheng, Xiangrong; Li, Shu’e; Miron, Richard J.; Wu, Tao; Chen, Wenli; Zhang, Yufeng
2018-01-01
The most common complication for patients with postmenopausal osteoporosis is bone-related defects and fractures. While routine medication has a high probability of undesirable side effects, new approaches have aimed to develop regeneration procedures that stimulate new bone formation while reversing bone loss. Recently, we have synthesized a new hybrid CaP/silk scaffold with a CaP-phase distribution and pore architecture better suited to facilitate cell differentiation and bone formation. The aim of the present study was to compare the involved remodeling process and therapeutic effect of porous CaP/silk composite scaffolds upon local implantation into osteoporotic defects. Wistar rats were used to induce postmenopausal osteoporotic model by bilateral ovariectomy. The pure silk and hybrid CaP/silk scaffolds were implanted into critical sized defects created in distal femoral epiphysis. After 14 and 28 days, the in vivo osteogenetic efficiency was evaluated by μCT analysis, hematoxylin and eosin staining, Safranin O staining, tartrate-resistant acid phosphatase staining, and immunohistochemical assessment. Animals with or without critical-sized defects were used as drill or blank controls, respectively. The osteoporotic defect model was well established with significantly decreased μCT parameters of BV/TV, Tb.N and increased Tb.Sp, porosity, combined with changes in histological observations. During the healing process, the critical-sized drill control defects failed to regenerate appreciable bone tissue, while more significantly increased bone formation and mineralization with dynamic scaffold degradation and decreased osteoclastic bone resorption could be detected within defects with hybrid CaP/silk scaffolds compared to pure silk scaffolds. PMID:23674058
Porous CaP/silk composite scaffolds to repair femur defects in an osteoporotic model.
Cheng, Ning; Dai, Jing; Cheng, Xiangrong; Li, Shu'e; Miron, Richard J; Wu, Tao; Chen, Wenli; Zhang, Yufeng; Shi, Bin
2013-08-01
The most common complication for patients with postmenopausal osteoporosis is bone-related defects and fractures. While routine medication has a high probability of undesirable side effects, new approaches have aimed to develop regeneration procedures that stimulate new bone formation while reversing bone loss. Recently, we have synthesized a new hybrid CaP/silk scaffold with a CaP-phase distribution and pore architecture better suited to facilitate cell differentiation and bone formation. The aim of the present study was to compare the involved remodeling process and therapeutic effect of porous CaP/silk composite scaffolds upon local implantation into osteoporotic defects. Wistar rats were used to induce postmenopausal osteoporotic model by bilateral ovariectomy. The pure silk and hybrid CaP/silk scaffolds were implanted into critical sized defects created in distal femoral epiphysis. After 14 and 28 days, the in vivo osteogenetic efficiency was evaluated by μCT analysis, hematoxylin and eosin staining, Safranin O staining, tartrate-resistant acid phosphatase staining, and immunohistochemical assessment. Animals with or without critical-sized defects were used as drill or blank controls, respectively. The osteoporotic defect model was well established with significantly decreased μCT parameters of BV/TV, Tb.N and increased Tb.Sp, porosity, combined with changes in histological observations. During the healing process, the critical-sized drill control defects failed to regenerate appreciable bone tissue, while more significantly increased bone formation and mineralization with dynamic scaffold degradation and decreased osteoclastic bone resorption could be detected within defects with hybrid CaP/silk scaffolds compared to pure silk scaffolds.
Lu, Xiaozhao; Bai, Danna; Liu, Xiangwei; Zhou, Chen; Yang, Guodong
2017-01-01
Pioneering epidemiological work has established strong association of sedentary lifestyle and obesity with the risk of colorectal cancer, while the detailed underlying mechanism remains unknown. Here we show that Hotair (HOX transcript antisense RNA) is a pro-adipogenic long non-coding RNA highly expressed in gluteal-femoral fat over other fat depots. Hotair knockout in adipose tissue results in gluteal-femoral fat defect. Squeeze of the gluteal-femoral fat induces intestinal proliferation in wildtype mice, while not in Hotair knockout mice. Mechanistically, squeeze of the gluteal-femoral fat induces exosomal Hotair secretion mainly by transcriptional upregulation of Hotair via NFκB. And increased exosomal Hotair in turn circulates in the blood and is partially endocytosed by the intestine, finally promoting the stemness and proliferation of intestinal stem/progenitor cells via Wnt activation. Clinically, obese subjects with sedentary lifestyle have much higher exosomal HOTAIR expression in the serum. These findings establish that sedentary lifestyle promotes exosomal Hotair release from the gluteal-femoral fat, which in turn facilitates intestinal stem and/or progenitor proliferation, raising a possible link between sedentary lifestyle with colorectal tumorigenesis. PMID:28361920
Lu, Xiaozhao; Bai, Danna; Liu, Xiangwei; Zhou, Chen; Yang, Guodong
2017-03-31
Pioneering epidemiological work has established strong association of sedentary lifestyle and obesity with the risk of colorectal cancer, while the detailed underlying mechanism remains unknown. Here we show that Hotair (HOX transcript antisense RNA) is a pro-adipogenic long non-coding RNA highly expressed in gluteal-femoral fat over other fat depots. Hotair knockout in adipose tissue results in gluteal-femoral fat defect. Squeeze of the gluteal-femoral fat induces intestinal proliferation in wildtype mice, while not in Hotair knockout mice. Mechanistically, squeeze of the gluteal-femoral fat induces exosomal Hotair secretion mainly by transcriptional upregulation of Hotair via NFκB. And increased exosomal Hotair in turn circulates in the blood and is partially endocytosed by the intestine, finally promoting the stemness and proliferation of intestinal stem/progenitor cells via Wnt activation. Clinically, obese subjects with sedentary lifestyle have much higher exosomal HOTAIR expression in the serum. These findings establish that sedentary lifestyle promotes exosomal Hotair release from the gluteal-femoral fat, which in turn facilitates intestinal stem and/or progenitor proliferation, raising a possible link between sedentary lifestyle with colorectal tumorigenesis.
Dumas, Jerald E.; Prieto, Edna M.; Zienkiewicz, Katarzyna J.; Guda, Teja; Wenke, Joseph C.; Bible, Jesse; Holt, Ginger E.
2014-01-01
There is a compelling clinical need for bone grafts with initial bone-like mechanical properties that actively remodel for repair of weight-bearing bone defects, such as fractures of the tibial plateau and vertebrae. However, there is a paucity of studies investigating remodeling of weight-bearing bone grafts in preclinical models, and consequently there is limited understanding of the mechanisms by which these grafts remodel in vivo. In this study, we investigated the effects of the rates of new bone formation, matrix resorption, and polymer degradation on healing of settable weight-bearing polyurethane/allograft composites in a rabbit femoral condyle defect model. The grafts induced progressive healing in vivo, as evidenced by an increase in new bone formation, as well as a decrease in residual allograft and polymer from 6 to 12 weeks. However, the mismatch between the rates of autocatalytic polymer degradation and zero-order (independent of time) new bone formation resulted in incomplete healing in the interior of the composite. Augmentation of the grafts with recombinant human bone morphogenetic protein-2 not only increased the rate of new bone formation, but also altered the degradation mechanism of the polymer to approximate a zero-order process. The consequent matching of the rates of new bone formation and polymer degradation resulted in more extensive healing at later time points in all regions of the graft. These observations underscore the importance of balancing the rates of new bone formation and degradation to promote healing of settable weight-bearing bone grafts that maintain bone-like strength, while actively remodeling. PMID:23941405
Russell, Robert D; Huo, Michael H; Rodrigues, Danieli C; Kosmopoulos, Victor
2016-11-14
Stable femoral fixation during uncemented total hip arthroplasty is critical to allow for subsequent osseointegration of the prosthesis. Varying stem designs provide surgeons with multiple options to gain femoral fixation. The purpose of this study was to compare the initial fixation stability of cylindrical and tapered stem implants using two different underreaming techniques (press-fit conditions) for revision total hip arthroplasty (THA). A finite element femur model was created from three-dimensional computed tomography images simulating a trabecular bone defect commonly observed in revision THA. Two 18-mm generic femoral hip implants were modeled using the same geometry, differing only in that one had a cylindrical stem and the other had a 2 degree tapered stem. Surgery was simulated using a 0.05-mm and 0.01-mm press-fit and tested with a physiologically relevant loading protocol. Mean contact pressure was influenced more by the surgical technique than by the stem geometry. The 0.05-mm press-fit condition resulted in the highest contact pressures for both the cylindrical (27.35 MPa) and tapered (20.99 MPa) stems. Changing the press-fit to 0.01-mm greatly decreased the contact pressure by 79.8% and 78.5% for the cylindrical (5.53 MPa) and tapered (4.52 MPa) models, respectively. The cylindrical stem geometry consistently showed less relative micromotion at all the cross-sections sampled as compared to the tapered stem regardless of press-fit condition. This finite element analysis study demonstrates that tapered stem results in lower average contact pressure and greater micromotion at the implant-bone interface than a cylindrical stem geometry. More studies are needed to establish how these different stem geometries perform in such non-ideal conditions encountered in revision THA cases where less bone stock is available.
Tang, Xiaodong; Guo, Wei; Yang, Rongli; Yan, Taiqiang; Tang, Shun; Li, Dasen
2017-12-01
Pelvic reconstruction after periacetabular tumor resection is technically difficult and characterized by a high complication rate. Although endoprosthetic replacement can result in immediate postoperative functional recovery, biologic reconstructions with autograft may provide an enhanced prognosis in patients with long-term survival; however, little has been published regarding this approach. We therefore wished to evaluate whether whole-bulk femoral head autograft that is not contaminated by tumor can be used to reconstruct segmental bone defects after intraarticular resection of periacetabular tumors. In a pilot study, we evaluated (1) local tumor control, (2) complications, and (3) postoperative function as measured by the Musculoskeletal Tumor Society score. Between 2009 and 2015, we treated 13 patients with periacetabular malignant or aggressive benign tumors with en bloc resection, bulk femoral head autograft, and cemented THA (with or without a titanium acetabular reconstruction cup), and all were included for analysis here. During that time, the general indications for this approach were (1) patients anticipated to have a good oncologic prognosis and adequate surgical margins to allow this approach, (2) patients whose pelvic bone defects did not exceed two types (Types I + II or Types II + III as defined by Enneking and Dunham), and (3) patients whose medical insurance would not cover what otherwise might have been a pelvic tumor prosthesis. During this period, another 91 patients were treated with pelvic prosthetic replacement, which was our preferred approach. Median followup in this study was 36 months (range, 24-99 months among surviving patients; one patient died 8 months after surgery); no patients were lost to followup. Bone defects were Types II + III in five patients, and Types I + II in eight. After intraarticular resection, ipsilateral femoral head autograft combined with THA was used to reconstruct the segmental bone defect of the acetabulum. In patients with Types I + II resections, the connection between the sacrum and the acetabulum was reestablished with a fibular autograft or a titanium cage filled with dried bone-allograft particles which was enhanced by using a pedicle screw and rod system. Functional evaluation was done in 11 patients who remained alive and maintained the femoral head autograft at final followup; one other patient received secondary resection involving removal of the femoral head autograft and internal fixation, and was excluded from functional evaluation. Endpoints were assessed by chart review. Two patients experienced local tumor recurrence. Finally, eight patients did not show signs of the disease, one patient died of disease for local and distant tumor relapse, and four patients survived, but still had the disease. Three of these four patients had distant metastases without local recurrence and one had local control after secondary resection but still experienced system relapse. We observed the following complications: hematoma (one patient; treated surgically with hematoma clearance), delayed wound healing (one patient; treated by débridement), deep vein thrombosis (one patient), and hip dislocation (one patient; treated with open reduction). The median 1993 Musculoskeletal Tumor Society score was 83% (25 of 30 points; range, 19-29 points), and all patients were community ambulators; one used a cane, three used a walker, and nine did not use any assistive devices. In this small series at short-term followup, we found that reconstruction of segmental bone defects after intraarticular resection of periacetabular tumors with femoral head autograft does not appear to impede local tumor control; complications were in the range of what might be expected in a series of large pelvic reconstructions, and postoperative function was generally good. Level IV, therapeutic study.
Osteochondral Repair Using Porous Three-dimensional Nanocomposite Scaffolds in a Rabbit Model
ŻYLIŃSKA, BEATA; STODOLAK-ZYCH, EWA; SOBCZYŃSKA-RAK, ALEKSANDRA; SZPONDER, TOMASZ; SILMANOWICZ, PIOTR; ŁAŃCUT, MIROSŁAW; JAROSZ, ŁUKASZ; RÓŻAŃSKI, PAWEŁ; POLKOWSKA, IZABELA
2017-01-01
Aim: To evaluate the utility of a novel nanocomposite biomaterial consisting of poly-L/D-lactide, and hydroxyapatite bioceramics, enriched with sodium alginate in articular cartilage defect treatment. Materials and Methods: The biomaterial was prepared using the method of solvent casting and particle leaching. The study was conducted on 20 New Zealand White rabbits. Experimental osteochondral defects were created in the femoral trochlear grooves and filled with biomaterials. In control groups, the defects were left to spontaneously heal. The quality of newly-formed tissue was evaluated on the basis of macroscopic and histological assessment. Additionally the level of osteogenic and cartilage degradation markers were measured. Results: The majority of the defects from the treatment group were covered with tissue similar in structure and colour to healthy cartilage, whereas in the control group, tissue was uneven, and not integrated into the surrounding cartilage. Conclusion: The results obtained validate the choice of biomaterial used in this study as well as the method of its application. PMID:28882956
Zhang, Yadong; Cui, Xu; Zhao, Shichang; Wang, Hui; Rahaman, Mohamed N; Liu, Zhongtang; Huang, Wenhai; Zhang, Changqing
2015-02-04
The development of a new generation of injectable bone cements that are bioactive and have enhanced osteogenic capacity for rapid osseointegration is receiving considerable interest. In this study, a novel injectable cement (designated Sr-BBG) composed of strontium-doped borate bioactive glass particles and a chitosan-based bonding phase was prepared and evaluated in vitro and in vivo. The bioactive glass provided the benefits of bioactivity, conversion to hydroxyapatite, and the ability to stimulate osteogenesis, while the chitosan provided a cohesive biocompatible and biodegradable bonding phase. The Sr-BBG cement showed the ability to set in situ (initial setting time = 11.6 ± 1.2 min) and a compressive strength of 19 ± 1 MPa. The Sr-BBG cement enhanced the proliferation and osteogenic differentiation of human bone marrow-derived mesenchymal stem cells in vitro when compared to a similar cement (BBG) composed of chitosan-bonded borate bioactive glass particles without Sr. Microcomputed tomography and histology of critical-sized rabbit femoral condyle defects implanted with the cements showed the osteogenic capacity of the Sr-BBG cement. New bone was observed at different distances from the Sr-BBG implants within eight weeks. The bone-implant contact index was significantly higher for the Sr-BBG implant than it was for the BBG implant. Together, the results indicate that this Sr-BBG cement is a promising implant for healing irregularly shaped bone defects using minimally invasive surgery.
Fernandes, Rui; Lee, Jason
2007-10-01
The reconstruction of large avulsive tissue loss in the head and neck region is one of the most difficult tasks faced by reconstructive surgeons. The advent of free tissue transfer has improved our ability to predictably reconstruct these patients. One of the most recent advances in the field of microvascular surgery is the use of perforator flaps. We have used the lateral circumflex femoral artery perforator (LCFAP) flap for reconstructions in patients who have suffered severe gunshot wounds (GSWs) to the maxillofacial area. A retrospective chart review was conducted of patients treated with a LCFAP flap in our division for large defects of the face resulting from GSWs between July 2005 and July 2006. The patient's age and gender, site and size of defect, and degree of bone and soft tissue loss were recorded. Flap survival and donor site morbidity were noted as outcomes of the reconstruction. Four patients who met the inclusion criteria were identified. The success rate for the flaps was 100%. There was no partial necrosis of the flaps. The size of the defect ranged from 20 x 10 cm to 10 x 10 cm. None of the patients had donor site complications, and all donor sites were closed primarily. Use of the LCFAP flap for the reconstruction of large defects secondary to GSWs to the face is a reliable option for the immediate reconstruction of this patient population. The lateral circumflex femoral artery perforator (LCFAP) flap is at a site not involved in the immediate resuscitation of trauma patients, thus ensuring an intact vascular system. This fact makes the LCFAP flap a reliable source for small to large soft tissues for reconstructing avulsive soft tissue losses in the head and neck.
Fotopoulos, Vasileios Ch; Mouzopoulos, George; Floros, Themistoklis; Tzurbakis, Matthaios
2015-09-01
Osteonecrosis of the femoral head is a devastating complication of steroid administration and has rarely been observed in the treatment of immune thrombocytopenia. The treatment of osteochondral defects in advanced stages of avascular necrosis (AVN), characterized by collapse of the subchondral bone, remains an unsolved burden in orthopedic surgery. In this report, we present a case of a 19-year-old female that was admitted in the Emergency Department with walking disability and painful hip joint movement due to steroid-induced femoral head osteonecrosis. Two years before she was diagnosed with immune thrombocytopenia, for which she received pulse steroid therapy with high dose of dexamethasone and underwent a splenectomy. This case report is the first to describe the use of osteochondral autograft transplantation as a treatment of steroid-induced AVN of the femoral head due to immune thrombocytopenia at the age of 19 years with very good clinical and radiological results 3 years postoperatively.
Designer bFGF-incorporated d-form self-assembly peptide nanofiber scaffolds to promote bone repair.
He, Bin; Ou, Yunsheng; Chen, Shuo; Zhao, Weikang; Zhou, Ao; Zhao, Jinqiu; Li, Hong; Jiang, Dianming; Zhu, Yong
2017-05-01
d-Form and l-form peptide nanofiber scaffolds can spontaneously form stable β-sheet secondary structures and nanofiber hydrogel scaffolds, and hold some promise in hemostasis and wound healing. We report here on the synthetic self-assembling peptide d-RADA16 and l-RADA16 are both found to produce stable β-sheet secondary structure and nanofiber hydrogel scaffolds based on circular dichroism (CD) spectroscopy, transmission electron microscopy (TEM) and rheology analysis etc. d-RADA16 hydrogel and l-RADA16 hydrogel can enhance obvious bone repair in femoral condyle defects of the Sprague-Dawley (SD) rat model compared to PBS treatment. Based on micro-computed tomography (CT), it was revealed that d-RADA16 hydrogel and l-RADA16 hydrogel were capable to obtain the extensive bone healing. Histological evaluation also found that these two hydrogels facilitate the presence of more mature bone tissue within the femoral condyle defects. Additionally, d-RADA16 hydrogel showed some potential in storing and releasing basic-fibroblast growth factor (bFGF) which was able to further promote bone regeneration based on micro-CT analysis. These results indicate that d-form peptide nanofiber hydrogel have some special capacity for bone repair. Copyright © 2016 Elsevier B.V. All rights reserved.
Boss, J H; Misselevich, I; Bejar, J; Norman, D; Zinman, C; Reis, D N
2004-01-01
An impeded blood flow through the femoral head is incriminated in the etiopathogenesis of osteonecrosis of the femoral head. The disorder is either primary (idiopathic avascular osteonecrosis) or secondary to one condition or another, say, corticosteroid medication, fracture of the neck, coagulation defects, physical or thermal damage, storage disorders, alcoholism, and infectious, autoimmune as also marrow infiltrating diseases. In the wake of the necrosis, several mediators are released in increased amounts, prime among which is the vascular endothelial growth factor. The intermediates recruit endothelial progenitor cells, macrophages, osteoclasts, fibroblasts, and osteoblasts, which, pervading throughout the necrotic areas, initiate the reparative processes. The dead, soft and hard tissular debris is substituted by fibrous - later on by hematopoietic-fatty tissue - and bone. The newly formed, appositional and intramembranous bone is deficient in its mechanical properties. The ordinary load-carrying functions suffice to deform these weakened femoral heads so that osteoarthritic changes develop. Considering contemporary assumptions of the causes of osteonecrosis, oxygenation, revascularization, and core decompression are the realistic therapeutic interventions. Necrosis of rats' femoral heads is studied as a model of osteonecrosis in both adults and children. In view of rodents' lifelong persisting physeal cartilage, vascular deprivation-induced osteonecrosis in rats mimics children's Perthes disease. The experimental model, which is well suited to test treatment modalities, has been used to investigate the effects of exposure to hyperbaric oxygen with and without non-weight bearing, medication of enoxaparin, and creation of an intraosseous conduit on the remodeling of the avascular necrotic femoral head. Intriguingly, the shape of treated rats' femoral heads is disfigured to a greater degree than that of untreated animals. This is most likely due to the reduced yield strength and elastic modulus as well as the raised strain-to-failure of the recently formed bone making up the post-necrotic femoral heads. It follows that expedited osteogenesis is, counter intuition, detrimental to maintaining the hemispherical shape of the femoral head, and thus to an articulation with congruent load-bearing surfaces. If this is indeed the case, the remodeling of the necrotic femoral head should be delayed, rather than sped up, as the present day paradigm would have it. Bearing in mind that the dead osseous structures keep their mechanical attributes for quite a while, a slowed down new bone formation would favor the gradual replacement of the necrotic by living bone. Therefore, management of the adult patients with osteonecrosis and children with Perthes disease should focus on a slowly progressive substitution so that the decline of the bone's mechanical properties is kept to a minimum. One viable therapeutic mode is a medication of inhibitors of the vascular endothelial growth factor.
Instability of total hip replacement: A clinical study and determination of its risk factors.
Ezquerra-Herrando, L; Seral-García, B; Quilez, M P; Pérez, M A; Albareda-Albareda, J
2015-01-01
To determine the risk factors associated with prosthetic dislocation and simulate a finite element model to determine the safe range of movement of various inclination and anteversion cup positions. Retrospective Case Control study with 46 dislocated patients from 1994 to 2011. 83 randomly selected patients. Dislocation risk factors described in the literature were collected. A prosthetic model was simulated using finite elements with 28, 32, 36 mm heads, and a 52 mm cup. Acetabular position was 25°, 40°, and 60° tilt and with 0°, 15° and 25° anteversion. In extension of 0° and flexion of 90°, internal and external rotation was applied to analyze the range of movement, maximum resisting moment, and stress distribution in the acetabulum to impingement and dislocation. There was greater dislocation in older patients (p=0.002). Higher dislocation in fractures than in osteoarthritis (p=0.001). Less anteversion in dislocated patients (p=0.043). Longer femoral neck in dislocated patients (p=0.002). Finite element model: lower dislocation when there is more anteversion, tilt and bigger femoral heads. Advanced age and fractures are the major risk factors for dislocation. "Safe zone" of movement for dislocation avoidance is 40°-60° tilt and 15°-25° anteversion. Both the defect and excess of soft tissue tension predispose to dislocation. Bigger femoral heads are more stable. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.
Influence of stem design on the primary stability of megaprostheses of the proximal femur.
Kinkel, Stefan; Graage, Jan Dennis; Kretzer, Jan Philippe; Jakubowitz, Eike; Nadorf, Jan
2013-10-01
Extended bone defects of the proximal femur can be reconstructed by megaprostheses for which aseptic loosening constitutes one of the major failure modes. The basic requirement for long-term success of endoprostheses is primary stability. We therefore assessed whether sufficient primary stability can be achieved by four different megaprostheses in a standardised bone defect of the proximal femur and whether their different design leads to different fixation patterns. Four different designs of proximal femoral replacements were implanted into 16 Sawbones® after preparing segmental bone defects (AAOS type II). Primary rotational stability was analysed by application of a cyclic torque of ±7 Nm and measuring the relative micromotions between bone and implant at different levels. The main fixation zones and differences of fixation patterns of the stem designs were determined by an analysis of variance. All four implants exhibited micromotions below 150 μm, indicating adequate primary stability. Lowest micromotions for all designs were located near the femoral isthmus. The extent of primary stability and the global implant fixation pattern differed considerably and could be related to the different design concepts. All megaprostheses studied provided sufficient primary stability if the fixation conditions of the femoral isthmus were intact. The design characteristics of the different stems largely determined the extent of primary stability and fixation pattern. Understanding these different fixation types could help the surgeon to choose the most suitable implant if the fixation conditions in the isthmus are compromised.
Wieding, Jan; Souffrant, Robert; Fritsche, Andreas; Mittelmeier, Wolfram; Bader, Rainer
2012-01-01
The use of finite element analysis (FEA) has grown to a more and more important method in the field of biomedical engineering and biomechanics. Although increased computational performance allows new ways to generate more complex biomechanical models, in the area of orthopaedic surgery, solid modelling of screws and drill holes represent a limitation of their use for individual cases and an increase of computational costs. To cope with these requirements, different methods for numerical screw modelling have therefore been investigated to improve its application diversity. Exemplarily, fixation was performed for stabilization of a large segmental femoral bone defect by an osteosynthesis plate. Three different numerical modelling techniques for implant fixation were used in this study, i.e. without screw modelling, screws as solid elements as well as screws as structural elements. The latter one offers the possibility to implement automatically generated screws with variable geometry on arbitrary FE models. Structural screws were parametrically generated by a Python script for the automatic generation in the FE-software Abaqus/CAE on both a tetrahedral and a hexahedral meshed femur. Accuracy of the FE models was confirmed by experimental testing using a composite femur with a segmental defect and an identical osteosynthesis plate for primary stabilisation with titanium screws. Both deflection of the femoral head and the gap alteration were measured with an optical measuring system with an accuracy of approximately 3 µm. For both screw modelling techniques a sufficient correlation of approximately 95% between numerical and experimental analysis was found. Furthermore, using structural elements for screw modelling the computational time could be reduced by 85% using hexahedral elements instead of tetrahedral elements for femur meshing. The automatically generated screw modelling offers a realistic simulation of the osteosynthesis fixation with screws in the adjacent bone stock and can be used for further investigations. PMID:22470474
Wikiel, Krzysztof J; Eid, George M
2015-07-01
Recently new disease process, often referred to as athletic pubalgia (AP), has been acknowledged by the medical community. The patients suffering from this ailment present with unilateral or bilateral chronic groin pain associated with physical activity without a clear diagnosis of a groin hernia. Though physical therapy and medical treatments are considered first line remedies, some believe that surgical treatment may have better, quicker, and more durable outcomes and procedures aimed at groin reinforcement seem to relieve most of symptoms in the majority of the patients. Despite many surgeons consistently noting rectus insertion or adductor thinning, multiple hernia defects are often seen during dissections and the clinical significance of these findings is still not known. Between 2007 and 2011, 40 patients underwent an extra-peritoneal laparoscopic reinforcement of rectus abdominals and insertion of adductor muscles for AP. All patients underwent wide and bilateral groin dissection and the findings were cataloged. All of the patients presented with groin defects upon wide dissection. Thirty-four patients (85%) presented with small bilateral indirect inguinal defects and 28 (70%) of these patients did not have any additional defects. Five patients (12.5%) were found to have only unilateral inguinal hernia defects. One patient presented with a small direct defect. In addition to these defects, five patients (12.5%) had additional unilateral femoral hernias, whereas no patient had solitary femoral hernia defects. AP is a new diagnostic entity with poorly understood etiology. It mostly affects young active adults, often involved in competitive sports and surgical methods may be most effective at achieving the cure. In our experience all of the patients presented with groin defects, though not all were the same. It is our belief that these defects, although likely not the only component, play a significant role in the pathophysiology of AP.
Osteochondral Repair Using Porous Three-dimensional Nanocomposite Scaffolds in a Rabbit Model.
Żylińska, Beata; Stodolak-Zych, Ewa; Sobczyńska-Rak, Aleksandra; Szponder, Tomasz; Silmanowicz, Piotr; Łańcut, Mirosław; Jarosz, Łukasz; Różański, Paweł; Polkowska, Izabela
2017-01-01
To evaluate the utility of a novel nanocomposite biomaterial consisting of poly-L/D-lactide, and hydroxyapatite bioceramics, enriched with sodium alginate in articular cartilage defect treatment. The biomaterial was prepared using the method of solvent casting and particle leaching. The study was conducted on 20 New Zealand White rabbits. Experimental osteochondral defects were created in the femoral trochlear grooves and filled with biomaterials. In control groups, the defects were left to spontaneously heal. The quality of newly-formed tissue was evaluated on the basis of macroscopic and histological assessment. Additionally the level of osteogenic and cartilage degradation markers were measured. The majority of the defects from the treatment group were covered with tissue similar in structure and colour to healthy cartilage, whereas in the control group, tissue was uneven, and not integrated into the surrounding cartilage. The results obtained validate the choice of biomaterial used in this study as well as the method of its application. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
The development of bioresorbable composite polymeric implants with high mechanical strength
NASA Astrophysics Data System (ADS)
Sharma, Upma; Concagh, Danny; Core, Lee; Kuang, Yina; You, Changcheng; Pham, Quynh; Zugates, Greg; Busold, Rany; Webber, Stephanie; Merlo, Jonathan; Langer, Robert; Whitesides, George M.; Palasis, Maria
2018-01-01
Implants for the treatment of tissue defects should mimic the mechanical properties of the native tissue of interest and should be resorbable as well as biocompatible. In this work, we developed a scaffold from variants of poly(glycolic) acid which were braided and coated with an elastomer of poly(glycolide-co-caprolactone) and crosslinked. The coating of the scaffold with the elastomer led to higher mechanical strength in terms of compression, expansion and elasticity compared to braids without the elastomer coating. These composite scaffolds were found to have expansion properties similar to metallic stents, utilizing materials which are typically much weaker than metal. We optimized the mechanical properties of the implant by tuning the elastomer branching structure, crosslink density, and molecular weight. The scaffolds were shown to be highly resorbable following implantation in a porcine femoral artery. Biocompatibility was studied in vivo in an ovine model by implanting the scaffolds into femoral arteries. The scaffolds were able to support an expanded open lumen over 12 months in vivo and also fully resorbed by 18 months in the ovine model.
Rotationplasty of the lower limb for congenital defects of the femur.
Torode, I P; Gillespie, R
1983-11-01
The operative technique for combined fusion of the knee and rotationplasty of the limb in the management of congenital deficiency of the femur is presented. The technique described allows earlier definitive prosthetic fitting of a child with proximal femoral deficiency; it has reduced the number of operative procedures needed to obtain the optimal function from that deficient limb; and it has enabled these procedures to be performed at an earlier age. The technique differs from those previously described and represents a significant improvement in management of the patient with femoral deficiency.
Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis
Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko
2016-01-01
A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal femur bone causes difficulty in setting a cementless total hip prosthesis. Therefore, total hip arthroplasty using a cemented polished tapered stem was performed via a direct lateral approach. Using a cemented polished tapered stem allowed us to deal with the femoral bone transformation and bone substance defectiveness due to exostosis and also minimized the invasiveness of the operation. PMID:27127668
Bussewitz, Bradly; DeVries, J George; Dujela, Michael; McAlister, Jeffrey E; Hyer, Christopher F; Berlet, Gregory C
2014-07-01
Large bone defects present a difficult task for surgeons when performing single-stage, complex combined hindfoot and ankle reconstruction. There exist little data in a case series format to evaluate the use of frozen femoral head allograft during tibiotalocalcaneal arthrodesis in various populations in the literature. The authors evaluated 25 patients from 2003 to 2011 who required a femoral head allograft and an intramedullary nail. The average time of final follow-up visit was 83 ± 63.6 weeks (range, 10-265). Twelve patients healed the fusion (48%). Twenty-one patients resulted in a braceable limb (84%). Four patients resulted in major amputation (16%). This series may allow surgeons to more accurately predict the success and clinical outcome of these challenging cases. Level IV, case series. © The Author(s) 2014.
Jing, Lizhong; Zhang, Jiying; Leng, Huijie; Guo, Qinwei; Hu, Yuelin
2015-04-01
To demonstrate that iliac crest cartilage may be used to repair articular cartilage defects in the knees of rabbits. Full-thickness cartilage defects were created in the medial femoral condyle on both knees of 36 New Zealand white rabbits. The 72 defects were randomly assigned to be repaired with ipsilateral iliac crest cartilage (Group I), osteochondral tissues removed at defect creation (Group II), or no treatment (negative control, Group III). Animals were killed at 6, 12, and 24 weeks post-operatively. The repaired tissues were harvested for magnetic resonance imaging (MRI), histological studies (haematoxylin and eosin and immunohistochemical staining), and mechanical testing. At 6 weeks, the iliac crest cartilage graft was not yet well integrated with the surrounding articular cartilage, but at 12 weeks, the graft deep zone had partial ossification. By 24 weeks, the hyaline cartilage-like tissue was completely integrated with the surrounding articular cartilage. Osteochondral autografts showed more rapid healing than Group I at 6 weeks and complete healing at 12 weeks. Untreated defects were concave or partly filled with fibrous tissue throughout the study. MRI showed that Group I had slower integration with surrounding normal cartilage compared with Group II. The mechanical properties of Group I were significantly lower than those of Group II at 12 weeks, but this difference was not significant at 24 weeks. Iliac crest cartilage autografts were able to repair knee cartilage defects with hyaline cartilage and showed comparable results with osteochondral autografts in the rabbit model.
Osteolysis of the femur: principles of management.
Dunbar, M J; Blackley, H R; Bourne, R B
2001-01-01
Femoral osteolysis is and will remain an important cause of THA failures. The presentation is initially radiographic and patients may or may not become symptomatic. If so, pain is the most common symptom. Infection is the most common differential diagnosis and must be excluded. Osteolysis is usually progressive and may eventually lead to loss of implant fixation, implant fracture, or periprosthetic fracture. Multiple factors influence the decision to revise a femoral component, including the degree and type of bone loss, the rate at which it is progressing, the potential for fracture, the degree of symptoms, especially pain, and the activity level and general health of the patient. There are many options for revising failed femoral stems, each with varying degrees of success. The choice of technique and prosthesis used in the revision can be guided by a simple bone defect classification presented in this chapter. Revision of femoral components in these patients can be fraught with complications and poor results; hence, the importance of preoperative planning cannot be overemphasized.
Chan, V O; Moran, D E; Mwangi, I; Eustace, S J
2013-08-01
To determine the prevalence of chondromalacia isolated to the anterior margin of the lateral femoral condyle as a component of patellofemoral disease in patients with anterior knee pain and to correlate it with patient demographics, patellar shape, and patellofemoral alignment. Retrospective study over a 1-year period reviewing the MR knee examinations of all patients who were referred for assessment of anterior knee pain. Only patients with isolated lateral patellofemoral disease were included. Age, gender, distribution of lateral patellofemoral chondromalacia, and grade of cartilaginous defects were documented for each patient. Correlation between the distribution of lateral patellofemoral chondromalacia and patient demographics, patellar shape, and indices of patellar alignment (femoral sulcus angle and modified Q angle) was then ascertained. There were 50 patients (22 males, 28 females) with anterior knee pain and isolated patellofemoral disease. The majority of the patients (78 %) had co-existent disease with grade 1 chondromalacia. No significant correlation was found between patients with chondromalacia isolated to the anterior margin of the lateral femoral condyle and age, gender, patellar shape, or modified Q angle (p > 0.05). However, patients with chondromalacia isolated to the anterior margin of the lateral femoral condyle had a shallower femoral sulcus angle (mean 141.8°) compared to the patients with lateral patellar facet disease (mean 133.8°) (p = 0.002). A small percentage of patients with anterior knee pain have chondromalacia isolated to the anterior margin of the lateral femoral condyle. This was associated with a shallower femoral sulcus angle.
Femoral Reconstruction Using External Fixation
Palatnik, Yevgeniy; Rozbruch, S. Robert
2011-01-01
Background. The use of an external fixator for the purpose of distraction osteogenesis has been applied to a wide range of orthopedic problems caused by such diverse etiologies as congenital disease, metabolic conditions, infections, traumatic injuries, and congenital short stature. The purpose of this study was to analyze our experience of utilizing this method in patients undergoing a variety of orthopedic procedures of the femur. Methods. We retrospectively reviewed our experience of using external fixation for femoral reconstruction. Three subgroups were defined based on the primary reconstruction goal lengthening, deformity correction, and repair of nonunion/bone defect. Factors such as leg length discrepancy (LLD), limb alignment, and external fixation time and complications were evaluated for the entire group and the 3 subgroups. Results. There was substantial improvement in the overall LLD, femoral length discrepancy, and limb alignment as measured by mechanical axis deviation (MAD) and lateral distal femoral angle (LDFA) for the entire group as well as the subgroups. Conclusions. The Ilizarov external fixator allows for decreased surgical exposure and preservation of blood supply to bone, avoidance of bone grafting and internal fixation, and simultaneous lengthening and deformity correction, making it a very useful technique for femoral reconstruction. PMID:21991425
Patello-femoral and tibio-femoral contact forces during kicking type of activity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Engin, A.E.; Tumer, S.T.
1996-12-31
In this paper patello-femoral and tibia-femoral contact forces during kicking type of activity is presented by means of a dynamic model of the knee joint which includes tibio-femoral and patello-femoral articulations, and the major ligaments of the joint. The model shows that the patella can be subjected to very large transient patello-femoral contact forces during a strenuous lower limb activity such as kicking even under conditions of small knee-flexion angles.
Xie, Zhongjie; Weng, Sheji; Li, Hang; Yu, Xia; Lu, Shanshan; Huang, Kate; Wu, Zongyi; Bai, Bingli; Boodhun, Viraj; Yang, Lei
2017-12-01
Accumulating evidence suggests that early angiogenesis has an important effect on the healing of injury. Teriparatide (PTH) is extensively applied for its potent anabolic activity on bone, while little is known about its angiogenic ability which may facilitate new bone formation. In this study, we tested the angiogenic ability of PTH and its effect on degradation of β-tricalcium phosphate (β-TCP) in an ovariectomized (OVX) rat distal femoral metaphysis model. After successful establishment of the OVX model was confirmed, a critical size defect was drilled into each distal femur of the OVX rats. Afterwards all animals were randomly divided into three groups: control group, group β-TCP and group β-TCP+PTH, then rats of group β-TCP+PTH were injected Teriparatide (30 μg/kg) subcutaneous every other day. Four weeks after femur surgery, five specimens from each group were used for Microfil perfusion to reveal blood vessels in the bone defect. The residual rats were harvested for micro-computed tomography, histological analysis and immunochemistry. The results showed Teriparatide facilitated neovascularization, degradation of β-TCP and new bone formation in combination with β-TCP, which may be relevant to neovascularization in an early phase. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Hindle, Paul; Baily, James; Khan, Nusrat; Biant, Leela C; Simpson, A Hamish R; Péault, Bruno
2016-11-01
Previous research has indicated that purified perivascular stem cells (PSCs) have increased chondrogenic potential compared to conventional mesenchymal stem cells (MSCs) derived in culture. This study aimed to develop an autologous large animal model for PSC transplantation and to specifically determine if implanted cells are retained in articular cartilage defects. Immunohistochemistry and fluorescence-activated cell sorting were used to ascertain the reactivity of anti-human and anti-ovine antibodies, which were combined and used to identify and isolate pericytes (CD34 - CD45 - CD146 + ) and adventitial cells (CD34 + CD45 - CD146 - ). The purified cells demonstrated osteogenic, adipogenic, and chondrogenic potential in culture. Autologous ovine PSCs (oPSCs) were isolated, cultured, and efficiently transfected using a green fluorescence protein (GFP) encoding lentivirus. The cells were implanted into articular cartilage defects on the medial femoral condyle using hydrogel and collagen membranes. Four weeks following implantation, the condyle was explanted and confocal laser scanning microscopy demonstrated the presence of oPSCs in the defect repaired with the hydrogel. These data suggest the testability in a large animal of native MSC autologous grafting, thus avoiding possible biases associated with xenotransplantation. Such a setting will be used in priority for indications in orthopedics, at first to model articular cartilage repair.
Makitsubo, Manami; Adachi, Nobuo; Nakasa, Tomoyuki; Kato, Tomohiro; Shimizu, Ryo; Ochi, Mitsuo
2016-10-04
Although differences in the results of the bone marrow stimulation technique between the knee and ankle have been reported, a detailed mechanism for those differences has not been clarified. The purpose of this study was to examine whether morphological differences between the knee and ankle joint affect the results of drilling as treatment for osteochondral defects in a rabbit model. Osteochondral defects were created at the knee and ankle joint in the rabbit. In the knee, osteochondral defects were created at the medial femoral condyle (MFC) and patellar groove (PG). At the ankle, defects were created in the talus at either a covered or uncovered area by the tibial plafond. After creating the osteochondral defect, drilling was performed. At 4, 8, and 12 weeks after surgery, repair of the osteochondral defects were evaluated histologically. The proliferation of rabbit chondrocytes and proteoglycan release of cartilage tissue in response to IL-1β were analyzed in vitro in both joints. At 8 weeks after surgery, hyaline cartilage repair was observed in defects at the covered area of the talus and the MFC. At 12 weeks, hyaline cartilage with a normal thickness was observed for the defect at the covered area of the talus, but not for the defect at the MFC. At 12 weeks, subchondral bone formation progressed and a normal contour of subchondral bone was observed on CT in the defect at the covered area of the talus. No significant differences in chondrocyte proliferation rate and proteoglycan release were detected between the knee and ankle in vitro. Our results demonstrate that the covered areas of the talus show early and sufficient osteochondral repair compared to that of the knee and the uncovered areas of the talus. These results suggest that the congruent joint shows better subchondral repair prior to cartilage repair compared to that of the incongruent joint.
[The comparative characteristics of sawcuts across the femoral bone].
Sarkisian, B A; Azarov, P A
2014-01-01
The objective of the present work was to study the differences between the morphological features of the wounds in the long tubular bones inflicted by joinery hand saws designed for longitudinal and transverse, sawing. The experimental injuries to the femoral bones were inflicted by the recurring and reciprocating saw movements. The hand saws had 5 mm high "sharp" and "blunt"-tipped teeth. A total of 40 experiments were carried out. It was shown that the sawcuts across the femoral bones and their edges have different size, shape, and morphological characteristics (defects, ledges, projections, bright spots) depending on the type of the saw, the sharpness of its teeth, and the mode of sawing. The results of the study may be used to improve diagnostics of injuries to the long tubular bones inflicted by different types of joinery saws.
Long, Teng; Zhu, Zhenan; Awad, Hani A.; Schwarz, Edward M.; Hilton, Matthew J.; Dong, Yufeng
2014-01-01
Structural bone allografts are widely used in the clinic to treat critical sized bone defects, despite lacking the osteoinductive characteristics of live autografts. To address this, we generated revitalized structural allografts wrapped with mesenchymal stem/progenitor cell (MSC) sheets, which were produced by expanding primary syngenic bone marrow derived cells on temperature-responsive plates, as a tissue engineered periosteum. In vitro assays demonstrated maintenance of the MSC phenotype in the sheets, suggesting that short-term culturing of MSC sheets is not detrimental. To test their efficacy in vivo, allografts wrapped with MSC sheets were transplanted into 4-mm murine femoral defects and compared to allografts with direct seeding of MSCs and allografts without cells. Evaluations consisted of x-ray plain radiography, 3D microCT, histology, and biomechanical testing at 4- and 6-weeks post-surgery. Our findings demonstrate that MSC sheets induce prolonged cartilage formation at the graft-host junction and enhanced bone callus formation, as well as graft-host osteointegration. Moreover, a large periosteal callus was observed spanning the allografts with MSC sheets, which partially mimics live autograft healing. Finally, biomechanical testing showed a significant increase in the structural and functional properties of MSC sheet grafted femurs. Taken together, MSC sheets exhibit enhanced osteogenicity during critical sized bone defect repair, demonstrating the feasibility of this tissue engineering solution for massive allograft healing. PMID:24393269
Adjustable stiffness, external fixator for the rat femur osteotomy and segmental bone defect models.
Glatt, Vaida; Matthys, Romano
2014-10-09
The mechanical environment around the healing of broken bone is very important as it determines the way the fracture will heal. Over the past decade there has been great clinical interest in improving bone healing by altering the mechanical environment through the fixation stability around the lesion. One constraint of preclinical animal research in this area is the lack of experimental control over the local mechanical environment within a large segmental defect as well as osteotomies as they heal. In this paper we report on the design and use of an external fixator to study the healing of large segmental bone defects or osteotomies. This device not only allows for controlled axial stiffness on the bone lesion as it heals, but it also enables the change of stiffness during the healing process in vivo. The conducted experiments have shown that the fixators were able to maintain a 5 mm femoral defect gap in rats in vivo during unrestricted cage activity for at least 8 weeks. Likewise, we observed no distortion or infections, including pin infections during the entire healing period. These results demonstrate that our newly developed external fixator was able to achieve reproducible and standardized stabilization, and the alteration of the mechanical environment of in vivo rat large bone defects and various size osteotomies. This confirms that the external fixation device is well suited for preclinical research investigations using a rat model in the field of bone regeneration and repair.
Figueroa, D; Espinosa, M; Calvo, R; Scheu, M; Valderrama, J J; Gallegos, M; Conget, P
2014-01-01
To evaluate the effect of 2 different protocols of intra-articular hyaluronic acid (HA, hylan G-F20) to articular cartilage regeneration in acute full-thickness chondral defects. Full-thickness chondral defects of 3 x 6 mm were performed into the lateral femoral condyles of New Zealand rabbits, treated with a single or three doses of HA. The animals were sacrified at 12 weeks and the regenerated tissue was evaluated by direct observation and histology with the ICRS scale. Macroscopically, in both groups treated with HA the defects were filled with irregular tissue with areas similar to hyaline cartilage and others in which depressed areas with exposed subchondral bone were observed. Histological analysis showed in both groups treated with HA a hyaline-like cartilage compared to control group. However, the score of the International Cartilage Repair Society (ICRS) scale did not show differences between the groups treated with HA. The use of single dose or 3 doses of AH in acute chondral lesions has a limited and similar benefit in articular cartilage regeneration. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.
Detection of avascular necrosis in adults by single photon emission computed tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collier, B.D.; Johnston, R.P.; Carrera, G.
1984-01-01
Twenty-one adult patients with the clinical diagnosis of avascular necrosis (AVN) of the femoral head were examined with planar bone scintigraphy (high resolution collimator) and single photon emission computed tomography (SPECT). The duration of hip pain ranged from 1 day to 18 months. Risk factors (including steroids, renal transplantation, alcoholism, and trauma) were present in 17 cases. A final diagnosis of AVN (20 hips), osteochondral facture, or stress fracture, was established for 17 patients. The 4 remaining patients, who were radiographically normal and did not complain of pain 3 months later, were thought to have no significant bone pathology. SPECTmore » and planar bone scintigraphy were reported as positive for AVN only if a photopenic bony defect could be identified. In particular, uniformly increased activity throughout the femoral head was not considered to be diagnostic of AVN. The authors conclude that by identifying a photopenic defect which is not evident on planar bone scintigraphy, SPECT can contribute to accurate diagnosis of AVN.« less
Zarei, Allahdad; Hulley, Philippa A; Sabokbar, Afsie; Javaid, M Kassim
2017-06-01
Osteoarthritis (OA) is a progressively degenerative joint disease influenced by structural and metabolic factors. There is growing evidence that subchondral bone is involved in both symptomatic and structural progression in OA. The Wnt pathway has been implicated in the progression of OA but the expression and function of the Wnt inhibitors, Dikkopf (DKK-1) and sclerostin (SOST), are unclear. We examined the regional distribution of DKK-1 and SOST in subchondral bone of the femoral head using resection specimens following arthroplasty in patients presenting with end-stage OA. Cylindrical cores for immunohistochemistry were taken through midpoint of full thickness cartilage defect, partial cartilage defect, through base of osteophyte and through macroscopically normal cartilage. Subchondral bone was thickest in cores taken from regions with full cartilage defect and thinnest in cores taken from osteophyte regions. In subchondral bone, expression of both DKK-1 and SOST was observed exclusively in osteocytes. Expression was highest in subchondral bone in cores taken from regions with partial but not full thickness cartilage defects. DKK-1 but not SOST was expressed by chondrocytes in cores with macroscopically normal cartilage. The current study describes the regional cellular distribution of SOST and DKK-1 in hip OA. Expression was highest in the osteocytes in bone underlying partial thickness cartilage defects. It is however not clear if this is a cause or a consequence of alterations in the overlying cartilage. However, it is suggestive of an active remodeling process which might be targeted by disease-modifying agents.
Global fit concept in revision hip arthroplasty for cementless press-fit femoral stems.
Canovas, F; LeBeguec, P; Batard, J; Gaillard, F; Dagneaux, L
2017-06-01
A revision stem may be required after a femoral extended trochanteric osteotomy (ETO) is made during revision hip arthroplasty. The two main complications of straight cementless femoral stems are subsidence due to inadequate osteointegration and stress-shielding. We will describe an original revision method with ETO that uses a straight cementless stem. The goal of this method was to achieve the most extensive press-fit possible during stem implantation to improve the transmission of stresses to the bone and to prevent reduction in bone density. The intramedullary preparation was done after closure and fixation of the ETO, which allows impaction of the revision stem with metaphyseal and diaphyseal press-fit. We report encouraging results with preservation of periprosthetic bone stock and good osteointegration of these revision stems at the final follow-up. Pronounced sagittal curvature or large bone defects are contraindications for this technique. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Krueger, Alexander P; Singh, Gurpal; Beil, Frank Timo; Feuerstein, Bernd; Ruether, Wolfgang; Lohmann, Christoph H
2014-05-01
Ceramic components in total knee arthroplasty (TKA) are evolving. We analyze the first case of BIOLOX delta ceramic femoral component fracture. A longitudinal midline fracture in the patellar groove was present, with an intact cement mantle and no bony defects. Fractographic analysis with laser scanning microscopy and white light interferometry showed no evidence of arrest lines, hackles, wake hackles, material flaws, fatigue or crack propagation. Analysis of periprosthetic tissues with Fourier-transform infrared (FT-IR) microscopy, contact radiography, histology, and subsequent digestion and high-speed centrifugation did not show ceramic debris. A macrophage-dominated response was present around polyethylene debris. We conclude that ceramic femoral component failure in this case was related to a traumatic event. Further research is needed to determine the suitability of ceramic components in TKA. Copyright © 2014 Elsevier Inc. All rights reserved.
Bolia, Ioanna K; Briggs, Karen K; Locks, Renato; Chahla, Jorge; Utsunomiya, Hajime; Philippon, Marc J
2018-05-02
To compare the prevalence, size, and location of Outerbridge grade III and IV cartilage defects on the femoral head and acetabulum between patients with borderline acetabular dysplasia and patients with non-borderline dysplasia who underwent hip arthroscopy for femoroacetabular impingement (FAI). Patients aged 18 years or older who underwent primary hip arthroscopy for correction of FAI and labral repair from November 2005 to April 2016 were included. We excluded patients with previous hip surgery, a radiographic hip joint space of 2 mm or less, and/or a lateral center-edge angle (LCEA) of less than 20° or greater than 40°. The study patients were divided into 2 groups based on the LCEA on the anteroposterior pelvic radiograph: Patients with an LCEA between 20° and 25° were included in the borderline group, and patients with an LCEA between 25° and 40° were included in the non-borderline group. The prevalence, size, and location of Outerbridge grade III and IV chondral lesions on the femoral head and acetabulum were recorded intraoperatively. Comparisons between groups were performed with the Mann-Whitney U test for nonparametric testing and the t test for data that were normally distributed. Data were analyzed to calculate odds ratios associated with the various factors. In total, 2,429 patients (1,114 women and 1,315 men) met the inclusion criteria. The borderline group consisted of 305 patients (150 men and 155 women), whereas the non-borderline dysplasia group comprised 2,124 patients (1,165 men and 959 women). Outerbridge grade III and IV chondral lesions were found on the femoral head in 118 patients with borderline dysplasia (39%) and 127 patients with non-borderline dysplasia (6%) and on the acetabulum in 132 patients with borderline dysplasia (43%) and 874 patients with non-borderline dysplasia (41%). Patients with borderline dysplasia were 10 times more likely (95% confidence interval, 7.3-13.4; P < .001) to have a grade III or IV cartilage defect on the weight-bearing surface of the femoral head (P < .001) than patients with non-borderline dysplasia. On the acetabular side, no difference in the prevalence of severe cartilage damage was detected between the 2 groups (P = .588). The size of chondral damage was significantly greater in patients with borderline dysplasia on the acetabulum (P = .039) compared with the non-borderline dysplasia group. Patients with FAI and borderline dysplasia are at higher risk of having Outerbridge grade III and IV chondral damage on the femoral head than patients with non-borderline dysplastic hips. Borderline dysplastic hips also presented with significantly larger chondral defects on the acetabular surface. Level III, retrospective comparative study. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Long, Teng; Zhu, Zhenan; Awad, Hani A; Schwarz, Edward M; Hilton, Matthew J; Dong, Yufeng
2014-03-01
Structural bone allografts are widely used in the clinic to treat critical sized bone defects, despite lacking the osteoinductive characteristics of live autografts. To address this, we generated revitalized structural allografts wrapped with mesenchymal stem/progenitor cell (MSC) sheets, which were produced by expanding primary syngenic bone marrow derived cells on temperature-responsive plates, as a tissue-engineered periosteum. In vitro assays demonstrated maintenance of the MSC phenotype in the sheets, suggesting that short-term culturing of MSC sheets is not detrimental. To test their efficacy in vivo, allografts wrapped with MSC sheets were transplanted into 4-mm murine femoral defects and compared to allografts with direct seeding of MSCs and allografts without cells. Evaluations consisted of X-ray plain radiography, 3D microCT, histology, and biomechanical testing at 4- and 6-weeks post-surgery. Our findings demonstrate that MSC sheets induce prolonged cartilage formation at the graft-host junction and enhanced bone callus formation, as well as graft-host osteointegration. Moreover, a large periosteal callus was observed spanning the allografts with MSC sheets, which partially mimics live autograft healing. Finally, biomechanical testing showed a significant increase in the structural and functional properties of MSC sheet grafted femurs. Taken together, MSC sheets exhibit enhanced osteogenicity during critical sized bone defect repair, demonstrating the feasibility of this tissue engineering solution for massive allograft healing. Copyright © 2013 Elsevier Ltd. All rights reserved.
Bone regeneration using injectable BMP-7 loaded chitosan microparticles in rat femoral defect.
Mantripragada, Venkata P; Jayasuriya, Ambalangodage C
2016-06-01
Injectable chitosan microparticles were prepared using a simple coacervation method under physiologically friendly conditions by eliminating oil or toxic chemical, and employing low temperature and pressure for growth factor stability. Amount of 200 ng of bone morphogenetic protein-7 (BMP-7) was incorporated in the chitosan microparticles by two methods: encapsulating and coating techniques. These microparticles were tested in vivo to determine the biological response in a rat femoral bone defect at 6 and 12 weeks. Four groups (n=10) were tested which include two groups for BMP-7 incorporated microparticles (by two techniques), microparticles without BMP-7, and defect itself (negative control). Healthy bone formation was observed around the microparticles, which were only confined to the defect site and did not disperse. Histology indicated minor inflammatory response around the microparticles at 6 weeks, which reduced by 12 weeks. Micro-CT analysis of bone surface density and porosity was found to be significantly more (p<0.05) for microparticles containing groups, in comparison with controls, which suggests that the new bone formed in the presence of microparticles is more interconnected and porous. Collagen fibrils analysis conducted using multiphoton microscopy showed significant improvement in the formation of bundled collagen area (%) in microparticles containing groups in comparison with controls, indicating higher cross-linking between the fibrils. Microparticles were biocompatible and did not degrade in the 12 week implant period. Copyright © 2016 Elsevier B.V. All rights reserved.
Jing, Da; Zhai, Mingming; Tong, Shichao; Xu, Fei; Cai, Jing; Shen, Guanghao; Wu, Yan; Li, Xiaokang; Xie, Kangning; Liu, Juan; Xu, Qiaoling; Luo, Erping
2016-01-01
Treatment of osseous defects remains a formidable clinical challenge. Porous titanium alloys (pTi) have been emerging as ideal endosseous implants due to the excellent biocompatibility and structural properties, whereas inadequate osseointegration poses risks for unreliable long-term implant stability. Substantial evidence indicates that pulsed electromagnetic fields (PEMF), as a safe noninvasive method, inhibit osteopenia/osteoporosis experimentally and clinically. We herein investigated the efficiency and potential mechanisms of PEMF on osteogenesis and osseointegration of pTi in vitro and in vivo. We demonstrate that PEMF enhanced cellular attachment and proliferation, and induced well-organized cytoskeleton for in vitro osteoblasts seeded in pTi. PEMF promoted gene expressions in Runx2, OSX, COL-1 and Wnt/β-catenin signaling. PEMF-stimulated group exhibited higher Runx2, Wnt1, Lrp6 and β-catenin protein expressions. In vivo results via μCT and histomorphometry show that 6-week and 12-week PEMF promoted osteogenesis, bone ingrowth and bone formation rate of pTi in rabbit femoral bone defect. PEMF promoted femoral gene expressions of Runx2, BMP2, OCN and Wnt/β-catenin signaling. Together, we demonstrate that PEMF improve osteogenesis and osseointegration of pTi by promoting skeletal anabolic activities through a Wnt/β-catenin signaling-associated mechanism. PEMF might become a promising biophysical modality for enhancing the repair efficiency and quality of pTi in bone defect. PMID:27555216
Keeney, Michael; van den Beucken, Jeroen J J P; van der Kraan, Peter M; Jansen, John A; Pandit, Abhay
2010-04-01
Collagen/calcium phosphate scaffolds have been used for bone reconstruction due to their inherent similarities to the bone extracellular matrix. Calcium phosphate alone has also been used as a non-viral vector for gene delivery. The aim of this study was to determine the capability of a collagen/calcium phosphate scaffold to deliver naked plasmid DNA and mediate transfection in vivo. The second goal of the study was to deliver a plasmid encoding vascular endothelial growth factor(165) (pVEGF(165)) to promote angiogenesis, and hence bone formation, in a mouse intra-femoral model. The delivery of naked plasmid DNA resulted in a 7.6-fold increase in mRNA levels of beta-Galactosidase compared to the delivery of plasmid DNA complexed with a partially degraded PAMAM dendrimer (dPAMAM) in a subcutaneous murine model. When implanted in a muirne intra-femoral model, the delivery of pVEGF(165) resulted in a 2-fold increase in bone volume at the defect site relative to control scaffolds without pVEGF(165). It was concluded that a collagen/calcium phosphate scaffold can mediate transfection without the use of additional transfection vectors and can promote bone formation in a mouse model via the delivery of pVEGF(165). 2009 Elsevier Ltd. All rights reserved.
Zhu, Shan; Liu, Yuanbo; Yu, Shengji; Zang, Mengqing; Zhao, Zhenguo; Xu, Libin; Zhang, Xinxin; Chen, Bo; Ding, Qiang
2016-01-01
To explore the feasibility and technical essentials of soft tissue defect reconstruction following malignant tumor removal of limbs using perforator propeller flaps. Between July 2008 and July 2015, 19 patients with malignant limb tumor underwent defect reconstruction following tumor removal using the perforator propeller flaps. There were 13 males and 6 females with an average age of 53.4 years (range, 20-82 years). The disease duration ranged from 1 to 420 months (mean, 82 months). The tumors located at the thigh in 10 cases, at the leg in 2 cases, at the arm in 1 case, at the forearm in 1 case, around the knee in 2 cases, and around the elbow joint in 3 cases. Totally 23 flaps (from 8 cm x 3 cm to 30 cm x 13 cm in size) were used to reconstruct defects (from 4 cm x 4 cm to 24 cm x 16 cm in size). The potential source arteries included the femoral artery (n = 2), profunda femoral artery (n = 3), superficial circumflex iliac artery (n = 1), lateral circumflex femoral artery (n = 6), superior lateral genicular artery (n = 2), peroneal artery (n = 2), anterior tibial artery (n = 1), brachial artery (n = 4), and radial artery (n = 1). The remaining one was a free style perforator flap. Partial distal flap necrosis occurred in 3 cases after surgery with rotation angles of 180, 150, and 100 degrees respectively, which were reconstructed after debridement using a free-style perforator flap in 1 case and using free skin grafting in the other 2 cases. The other 20 flaps survived completely after surgery. Primary healing of incisions was obtained at the donor and recipient sites. There was no severe complication such as infection, hematoma, and total flap failure. All patients were followed up 3 months to 5 years (mean, 19 months). One patient with malignant melanoma around the elbow joint had tumor recurrence, and underwent secondary tumor resection. The appearance, texture, and color of the flaps were similar to those at the recipient site. For patients with malignant tumor of the limb, the perforator propeller flap can be an alternative option for soft tissue defect reconstruction after tumor resection, with the advantages of relatively simple operation and remaining the main vessels.
Schmal, Hagen; Kowal, Justyna M; Kassem, Moustapha; Seidenstuecker, Michael; Bernstein, Anke; Böttiger, Katharina; Xiong, Tanshiyue; Südkamp, Norbert P; Kubosch, Eva J
2018-01-01
Known problems of the autologous chondrocyte implantation motivate the search for cellular alternatives. The aim of the study was to test the potential of synovium-derived stem cells (SMSC) to regenerate cartilage using a matrix-associated implantation. In an osteochondral defect model of the medial femoral condyle in a rabbit, a collagen membrane was seeded with either culture-expanded allogenic chondrocytes or SMSC and then transplanted into the lesion. A tailored piece synovium served as a control. Rabbit SMSC formed typical cartilage in vitro. Macroscopic evaluation of defect healing and the thickness of the regenerated tissue did not reveal a significant difference between the intervention groups. However, instantaneous and shear modulus, reflecting the biomechanical strength of the repair tissue, was superior in the implantation group using allogenic chondrocytes ( p < 0.05). This correlated with a more chondrogenic structure and higher proteoglycan expression, resulting in a lower OARSI score ( p < 0.05). The repair tissue of all groups expressed comparable amounts of the collagen types I, II, and X. Cartilage regeneration following matrix-associated implantation using allogenic undifferentiated synovium-derived stem cells in a defect model in rabbits showed similar macroscopic results and collagen composition compared to amplified chondrocytes; however, biomechanical characteristics and histological scoring were inferior.
Kowal, Justyna M.; Seidenstuecker, Michael; Bernstein, Anke; Böttiger, Katharina; Xiong, Tanshiyue; Südkamp, Norbert P.
2018-01-01
Known problems of the autologous chondrocyte implantation motivate the search for cellular alternatives. The aim of the study was to test the potential of synovium-derived stem cells (SMSC) to regenerate cartilage using a matrix-associated implantation. In an osteochondral defect model of the medial femoral condyle in a rabbit, a collagen membrane was seeded with either culture-expanded allogenic chondrocytes or SMSC and then transplanted into the lesion. A tailored piece synovium served as a control. Rabbit SMSC formed typical cartilage in vitro. Macroscopic evaluation of defect healing and the thickness of the regenerated tissue did not reveal a significant difference between the intervention groups. However, instantaneous and shear modulus, reflecting the biomechanical strength of the repair tissue, was superior in the implantation group using allogenic chondrocytes (p < 0.05). This correlated with a more chondrogenic structure and higher proteoglycan expression, resulting in a lower OARSI score (p < 0.05). The repair tissue of all groups expressed comparable amounts of the collagen types I, II, and X. Cartilage regeneration following matrix-associated implantation using allogenic undifferentiated synovium-derived stem cells in a defect model in rabbits showed similar macroscopic results and collagen composition compared to amplified chondrocytes; however, biomechanical characteristics and histological scoring were inferior. PMID:29765410
Kang, Xiangang; Zhao, Zhiyuan; Wu, Xuzhi; Shen, Qingxin; Wang, Zhiqiang; Kang, Yue; Xing, Zhenguang; Zhang, Tao
2016-03-01
To explore the feasibility of chitosan/allogeneic bone powder composite porous scaffold as scaffold material of bone tissue engineering in repairing bone defect. The composite porous scaffolds were prepared with chitosan and decalcified allogeneic bone powder at a ratio of 1 : 5 by vacuum freeze-drying technique. Chitosan scaffold served as control. Ethanol alternative method was used to measure its porosity, and scanning electron microscopy (SEM) to measure pore size. The hole of 3.5 mm in diameter was made on the bilateral femoral condyles of 40 adult Sprague Dawley rats. The composite porous scaffolds and chitosan scaffolds were implanted into the hole of the left femoral condyle (experimental group) and the hole of the right femoral condyle (control group), respectively. At 2, 4, 8, and 12 weeks after implantation, the tissues were harvested for gross observation, histological observation, and immunohistochemical staining. The composite porous scaffold prepared by vacuum freeze-drying technique had yellowish color, and brittle and easily broken texture; pore size was mostly 200-300 μm; and the porosity was 76.8% ± 1.1%, showing no significant difference when compared with the porosity of pure chitosan scaffold (78.4% ± 1.4%) (t = -2.10, P = 0.09). The gross observation and histological observation showed that the defect area was filled with new bone with time, and new bone of the experimental group was significantly more than that of the control group. At 4, 8, and 12 weeks after implantation, the bone forming area of the experimental group was significantly larger than that of the control group (P < 0.05). The immunohistochemical staining results showed that osteoprotegerin (OPG) positive expression was found in the experimental group at different time points, and the positive expression level was significantly higher than that in the control group (P < 0.05). Chitosan/allogeneic bone powder composite porous scaffold has suitable porosity and good osteogenic activity, so it is a good material for repairing bone defect, and its bone forming volume and bone formation rate are better than those of pure chitosan scaffold.
[RESEARCH PROGRESS OF EXPERIMENTAL ANIMAL MODELS OF AVASCULAR NECROSIS OF FEMORAL HEAD].
Yu, Kaifu; Tan, Hongbo; Xu, Yongqing
2015-12-01
To summarize the current researches and progress on experimental animal models of avascular necrosis of the femoral head. Domestic and internation literature concerning experimental animal models of avascular necrosis of the femoral head was reviewed and analyzed. The methods to prepare the experimental animal models of avascular necrosis of the femoral head can be mainly concluded as traumatic methods (including surgical, physical, and chemical insult), and non-traumatic methods (including steroid, lipopolysaccharide, steroid combined with lipopolysaccharide, steroid combined with horse serum, etc). Each method has both merits and demerits, yet no ideal methods have been developed. There are many methods to prepare the experimental animal models of avascular necrosis of the femoral head, but proper model should be selected based on the aim of research. The establishment of ideal experimental animal models needs further research in future.
Wieding, Jan; Souffrant, Robert; Mittelmeier, Wolfram; Bader, Rainer
2013-04-01
Repairing large segmental defects in long bones caused by fracture, tumour or infection is still a challenging problem in orthopaedic surgery. Artificial materials, i.e. titanium and its alloys performed well in clinical applications, are plenary available, and can be manufactured in a wide range of scaffold designs. Although the mechanical properties are determined, studies about the biomechanical behaviour under physiological loading conditions are rare. The goal of our numerical study was to determine the suitability of open-porous titanium scaffolds to act as bone scaffolds. Hence, the mechanical stability of fourteen different scaffold designs was characterized under both axial compression and biomechanical loading within a large segmental distal femoral defect of 30mm. This defect was stabilized with an osteosynthesis plate and physiological hip reaction forces as well as additional muscle forces were implemented to the femoral bone. Material properties of titanium scaffolds were evaluated from experimental testing. Scaffold porosity was varied between 64 and 80%. Furthermore, the amount of material was reduced up to 50%. Uniaxial compression testing revealed a structural modulus for the scaffolds between 3.5GPa and 19.1GPa depending on porosity and material consumption. The biomechanical testing showed defect gap alterations between 0.03mm and 0.22mm for the applied scaffolds and 0.09mm for the intact bone. Our results revealed that minimizing the amount of material of the inner core has a smaller influence than increasing the porosity when the scaffolds are loaded under biomechanical loading. Furthermore, an advanced scaffold design was found acting similar as the intact bone. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
Efe, Turgay; Schofer, Markus D; Füglein, Alexander; Timmesfeld, Nina; Fuchs-Winkelmann, Susanne; Stein, Thomas; El-Zayat, Bilal Farouk; Paletta, Jürgen Rj; Heyse, Thomas J
2010-12-15
Primary stability of cartilage repair constructs is of the utmost importance in the clinical setting but few continuous passive motion (CPM) models are available. Our study aimed to establish a novel ex vivo CPM animal model and to evaluate the required motion cycles for testing the mechanical properties of a new cell-free collagen type I gel plug (CaReS®-1S). A novel ex vivo CPM device was developed. Full-thickness cartilage defects (11 mm diameter by 6 mm deep) were created on the medial femoral condyle of porcine knee specimens. CaReS®-1S was implanted in 16 animals and each knee underwent continuous passive motion. After 0, 2000, 4000, 6000, and 8000 motions, standardized digital pictures of the grafts were taken, focusing on the worn surfaces. The percentage of worn surface on the total CaReS®-1S surface was evaluated with image processing software. Significant differences in the worn surface were recorded between 0 and 2000 motion cycles (p < 0.0001). After 2000 motion cycles, there was no significant difference. No total delamination of CaReS®-1S with an empty defect site was recorded. The ex vivo CPM animal model is appropriate in investigating CaReS®-1S durability under continuous passive motion. 2000 motion cycles appear adequate to assess the primary stability of type I collagen gels used to repair focal chondral defects.
2010-01-01
Background Primary stability of cartilage repair constructs is of the utmost importance in the clinical setting but few continuous passive motion (CPM) models are available. Our study aimed to establish a novel ex vivo CPM animal model and to evaluate the required motion cycles for testing the mechanical properties of a new cell-free collagen type I gel plug (CaReS®-1S). Methods A novel ex vivo CPM device was developed. Full-thickness cartilage defects (11 mm diameter by 6 mm deep) were created on the medial femoral condyle of porcine knee specimens. CaReS®-1S was implanted in 16 animals and each knee underwent continuous passive motion. After 0, 2000, 4000, 6000, and 8000 motions, standardized digital pictures of the grafts were taken, focusing on the worn surfaces. The percentage of worn surface on the total CaReS®-1S surface was evaluated with image processing software. Results Significant differences in the worn surface were recorded between 0 and 2000 motion cycles (p < 0.0001). After 2000 motion cycles, there was no significant difference. No total delamination of CaReS®-1S with an empty defect site was recorded. Conclusion The ex vivo CPM animal model is appropriate in investigating CaReS®-1S durability under continuous passive motion. 2000 motion cycles appear adequate to assess the primary stability of type I collagen gels used to repair focal chondral defects. PMID:21159196
Three-stage treatment protocol for recalcitrant distal femoral nonunion.
Ma, Ching-Hou; Chiu, Yen-Chun; Tu, Yuan-Kun; Yen, Cheng-Yo; Wu, Chin-Hsien
2017-04-01
In this study, we proposed a three-stage treatment protocol for recalcitrant distal femoral nonunion and aimed to analyze the clinical results. We retrospective reviewed 12 consecutive patients with recalcitrant distal femoral nonunion undergoing our three-stage treatment protocol from January 2010 to December 2014 in our institute. The three-stage treatment protocol comprised debridement of the nonunion site, lengthening to eliminate leg length discrepancy, deformity correction, stabilization with a locked plate, filling of the defect with cement spacer for inducing membrane formation, and bone reconstruction using a cancellous bone autograft (Masquelet technique) or free vascularized fibular bone graft. The bone union time, wound complication, lower limbs alignment, amount of lengthening, knee range of motion, and functional outcomes were evaluated. Osseous union with angular deformity <5° and leg length discrepancy <1 cm were achieved in all the patients. The average amount of lengthening was 5.88 cm (range 3.5-12 cm). Excellent or good outcomes were obtained in 9 patients. Although the current study involved only a small number of patients and the intervention comprised three stages, we believe that such a protocol may be a valuable alternative for the treatment of recalcitrant distal femoral nonunion.
Histology of 8 atypical femoral fractures: remodeling but no healing.
Schilcher, Jörg; Sandberg, Olof; Isaksson, Hanna; Aspenberg, Per
2014-06-01
The pathophysiology behind bisphosphonate-associated atypical femoral fractures remains unclear. Histological findings at the fracture site itself may provide clues. Between 2008 and 2013, we collected bone biopsies including the fracture line from 4 complete and 4 incomplete atypical femoral fractures. 7 female patients reported continuous bisphosphonate use for 10 years on average. 1 patient was a man who was not using bisphosphonates. Dual-energy X-ray absorptiometry of the hip and spine showed no osteoporosis in 6 cases. The bone biopsies were evaluated by micro-computed tomography, infrared spectroscopy, and qualitative histology. Incomplete fractures involved the whole cortical thickness and showed a continuous gap with a mean width of 180 µm. The gap contained amorphous material and was devoid of living cells. In contrast, the adjacent bone contained living cells, including active osteoclasts. The fracture surfaces sometimes consisted of woven bone, which may have formed in localized defects caused by surface fragmentation or resorption. Atypical femoral fractures show signs of attempted healing at the fracture site. The narrow width of the fracture gap and its necrotic contents are compatible with the idea that micromotion prevents healing because it leads to strains within the fracture gap that preclude cell survival.
Łapaj, Łukasz; Wendland, Justyna; Markuszewski, Jacek; Mróz, Adrian; Wiśniewski, Tomasz
2015-03-01
Data regarding in vivo performance of titanium nitride (TiN) coated prosthetic femoral heads is scarce, and available studies of older generations of implants demonstrated coating wear in vivo. That is why we conducted a retrieval analysis of 11 femoral heads (articulating in vivo for 1-56 months) with TiN film formed using physical vapor deposition (PVD), to verify if coating failure is a problem in contemporary implants. Retrieved implants were examined using scanning electron microscope, coating roughness was evaluated with a contact profilometer and adhesion was tested using a Rockwell HRC test according to VDI 3824 guideline. Although no gross failure of the TiN coating was observed in our retrievals, all implants had defects typical for PVD coatings, such as pinholes, small titanium droplets and blisters with delaminated coating. In some heads the coating was contaminated with small niobium (Nb) droplets uniformly scattered on the entire surface of the film. Presence of Nb contamination was associated with an increased number and area of other types of defects and poorer coating adhesion. In one component, subjected to multiple dislocations we found severe delamination and cracking of the coating, increased roughness and the presence of third bodies. Our results indicate, that although wear of the coating is lower than seen in older generations of implants, inconsistent quality of the TiN film among different implants indicates the need for strict monitoring of the manufacturing process. Copyright © 2015 Elsevier Ltd. All rights reserved.
Repair of full-thickness cartilage defects with cells of different origin in a rabbit model.
Yan, Hui; Yu, Changlong
2007-02-01
The purpose of this study was to evaluate the repaired tissues formed in full-thickness cartilage defects in a rabbit model implanted with 4 types of chondrogenic cells, including chondrocytes, mesenchymal stem cells (MSCs) and fibroblasts from rabbit, and human umbilical cord blood (hUCB) stem cells. Chondrocytes, MSCs, and fibroblasts were isolated from 6-week-old New Zealand rabbits; hUCB stem cells were isolated from the umbilical cord blood of newborn children. These 4 types of cells were cultured in vitro and embedded in polylactic acid (PLA) matrices. Full-thickness defects were produced in the femoral trochlear grooves of both knees in 36 adult New Zealand White rabbits. Cell/PLA composites were transplanted into cartilage defects. A total of 5 groups were formed according to implanted cell type: Group A, chondrocytes; Group B, MSCs; Group C, fibroblasts; Group D, hUCB stem cells; and Group E, no cells (control group). Repaired tissues were evaluated grossly, histologically, and immunohistochemically at 6 weeks and 12 weeks after implantation. In Groups A and B, defects were repaired with hyaline-like cartilage. In Group C, defects were repaired with fibrous tissue. In Group D, defects were repaired primarily with fibrous tissue and scattered chondrocytes; in some specimens, defects were repaired with a thin layer of hyaline-like cartilage at 12 weeks. In Group E, defects were repaired with fibrous tissue. Histologic scores in Groups A and B were significantly higher than those in Groups C, D, and E at 6 and 12 weeks after transplantation. Full-thickness cartilage defects treated with chondrocyte or MSC transplantation were repaired with hyaline-like cartilage tissue, and repair was significantly better than in tissues treated with fibroblasts and hUCB stem cells, as well as in the control group. Repaired tissues treated with MSCs appeared to have better cell arrangement, subchondral bone remodeling, and integration with surrounding cartilage than did repaired tissues generated by chondrocyte implantation. MSCs might be the most suitable cell source for cartilage repair. Further investigation into hUCB stem cell transplantation is needed. In our study of rabbits, MSCs supplied the most promising cell source for cartilage repair.
Schmutzer, Michael; Aszodi, Attila
2017-04-01
The loss and degradation of articular cartilage tissue matrix play central roles in the process of osteoarthritis (OA). New models for evaluating cartilage repair/regeneration are thus of great value for transferring various culture systems into clinically relevant situations. The repair process can be better monitored in ex vivo systems than in in vitro cell cultures. I have therefore established an ex vivo defect model prepared from bovine femoral condyles for evaluating cartilage repair by the implantation of cells cultured in various ways, e.g., monolayer-cultured cells or suspension or pellet cultures of articular bovine chondrocytes representing different cell compactions with variable densities of chondrocytes. I report that the integrin subunit α10 was significantly upregulated in suspension-cultured bovine chondrocytes at passage P2 compared with monolayer-cultured cells at P1 (p = 0.0083) and P2 (p < 0.05). Suspension-cultured cells did not promote cartilage repair when compared with implanted monolayer-cultured chondrocytes and pellets: 24.0 ± 0.66% for suspension cells, 46.4 ± 2.9% for monolayer cells, and 127.64 ± 0.90% for pellets (p < 0.0001) of the original defect volume (percentage of defect). Additional cultivation with chondrogenesis-promoting growth factors TGF-β1 and BMP-2 revealed an enhancing effect on cartilage repair in all settings. The advantage and innovation of this system over in vitro differentiation (e.g., micromass, pellet) assays is the possibility of examining and evaluating cartilage regeneration in an environment in which implanted cells are embedded within native surrounding tissue at the defect site. Such ex vivo explants might serve as a better model system to mimic clinical situations. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
de Albuquerque, Paulo Cezar Vidal Carneiro; Dos Santos, Saulo Monteiro; de Andrade Aguiar, José Lamartine; Filho, Nicodemus Pontes; de Mello, Roberto José Vieira; Costa, Mariana Lúcia Correia Ramos; de Albuquerque Olbertz, Clarissa Miranda Carneiro; de Souza Almeida, Tarciana Mendonça; da Silva Santos, Alessandro Henrique; da Silva, Joacil Carlos
2011-01-01
To study the surface, coloring, consistency, continuity and healing of osteochondral defects produced in the femoral condyles of rabbits and filled with sugar cane biopolymer gel (SCBG), after 90, 120 and 180 days, and in comparison with a control group. Sixteen adult New Zealand white rabbits aged 6 to 7 months, weighing between 2 and 2.5 kg and without locomotor system abnormalities were studied. In all the animals, a defect was made in the femoral condyles of the right and left knees, measuring 3.2 mm in diameter and 4 mm in depth, using a trephine. The animals were divided into two groups: study group formed by the right knees, in which the medial and lateral condyles received implants of SCBG; and control group formed by the left knees, in which the medial and lateral condyles were allowed to heal naturally. The knees were assessed 90, 120 and 180 days after the operation. After the animals had been sacrificed, the anatomical specimens were resected and placed in Bouin's solution. They were then photographed with a Nikon Coolpix 5400(®) coupled to a Nikon SM2800(®) stereoscopic loupe, to analyze the surface, coloring, consistency, continuity and healing. The results were evaluated using the chi-square test. There were no significant differences in the macroscopic assessments of healing between the study and control groups. With regard to the surface, coloring, consistency, continuity and healing of the defects, the macroscopic appearance of the tissue repaired with SCBG was similar to that of the control group.
Sakellariou, Vasileios I; Babis, George C
2014-01-01
The number of revision total hip arthroplasties is expected to rise as the indications for arthroplasty will expand due to the aging population. The prevalence of extensive proximal femoral bone loss is expected to increase subsequently. The etiology of bone loss from the proximal femur after total hip arthroplasty is multifactorial. Stress shielding, massive osteolysis, extensive loosening and history of multiple surgeries consist the most common etiologies. Reconstruction of extensive bone loss of the proximal femur during a revision hip arthroplasty is a major challenge for even the most experienced orthopaedic surgeon. The amount of femoral bone loss and the bone quality of the remaining metaphyseal and diaphyseal bone dictate the selection of appropriate reconstructive option. These include the use of impaction allografting, distal press-fit fixation, allograft-prosthesis composites and tumor megaprostheses. This review article is a concise review of the current literature and provides an algorithmic approach for reconstruction of different types of proximal femoral bone defects. PMID:25405090
Amstutz, Harlan C; Le Duff, Michel J
2008-09-01
Hip resurfacing is currently the fastest growing hip procedure worldwide. We reviewed 1000 hips in 838 patients who received a Conserve Plus (Wright Medical Technology, Inc., Arlington, Tenn) resurfacing at a single institution. The mean age of the patients was 50.0 years with 74.7% male. The hips were resurfaced irrespective of femoral defect size or etiology. The mean follow-up was 5.6 years (range, 1.1-11.0 years). All clinical scores improved significantly (P < .05). There was no acetabular component loosening. Ten were converted to total hip arthroplasty for femoral neck fracture, 20 for femoral loosening, 2 for sepsis, and 1 for recurrent subluxations. The 5-year survivorship was 95.2% with no failures in hips implanted since 2002. Short-term failures can be prevented. First-generation surgical technique and a low body mass index were the most important risk factors for the procedure. Improvements in bone preparation significantly increased prosthetic survival in hips with risk factors for failure.
Stifle osteochondritis dissecans in snow leopards (Uncia uncia).
Herrin, Kimberly Vinette; Allan, Graeme; Black, Anthony; Aliah, Rhonda; Howlett, Cameron Rolfe
2012-06-01
Three snow leopard (Uncia uncia) cubs, female and male siblings and an unrelated female, had lameness attributed to osteochondritis dissecans (OCD) lesions noted at 6, 8, and 10 mo of age, respectively. All cubs were diagnosed with OCD via radiographs. The sibling cubs both had lesions of the right lateral femoral condyles, while the unrelated cub had bilateral lesions of the lateral femoral condyles. Subsequently, OCD was confirmed in all three cases during surgical correction of the lateral femoral condyle lesions via lateral stifle arthrotomies, flap removal, and debridement of the defect sites. Histopathology also supported the diagnosis of OCD. Postoperatively, the sibling cubs developed seromas at the incision sites and mild lameness, which resolved within a month. To date, two cubs have been orthopedically sound, while one of the sibling cubs has developed mild osteoarthritis. OCD has rarely been reported in domestic felids, and to the authors' knowledge these are the first reported cases of OCD in nondomestic felids.
Kanazawa, Masayuki; Tsuru, Kanji; Fukuda, Naoyuki; Sakemi, Yuta; Nakashima, Yasuharu; Ishikawa, Kunio
2017-06-01
This study aimed to evaluate in vivo behavior of a carbonate apatite (CO 3 Ap) block fabricated by compositional transformation via a dissolution-precipitation reaction using a calcium hydrogen phosphate dihydrate [DCPD: CaHPO 4 ·2H 2 O] block as a precursor. These blocks were used to reconstruct defects in the femur and tibia of rabbits, using sintered dense hydroxyapatite (HAp) blocks as the control. Both the CO 3 Ap and HAp blocks showed excellent tissue response and good osteoconductivity. HAp block maintained its structure even after 24 weeks of implantation, so no bone replacement of the implant was observed throughout the post-implantation period in either femoral or tibial bone defects. In contrast, CO 3 Ap was resorbed with increasing time after implantation and replaced with new bone. The CO 3 Ap block was resorbed approximately twice as fast at the metaphysis of the proximal tibia than at the epiphysis of the distal femur. The CO 3 Ap block was resorbed at an approximately linear change over time, with complete resorption was estimated by extrapolation of data at approximately 1-1.5 years. Hence, the CO 3 Ap block fabricated in this study has potential value as an ideal artificial bone substitute because of its resorption and subsequent replacement by bone.
Animal models for bone tissue engineering and modelling disease
Griffin, Michelle
2018-01-01
ABSTRACT Tissue engineering and its clinical application, regenerative medicine, are instructing multiple approaches to aid in replacing bone loss after defects caused by trauma or cancer. In such cases, bone formation can be guided by engineered biodegradable and nonbiodegradable scaffolds with clearly defined architectural and mechanical properties informed by evidence-based research. With the ever-increasing expansion of bone tissue engineering and the pioneering research conducted to date, preclinical models are becoming a necessity to allow the engineered products to be translated to the clinic. In addition to creating smart bone scaffolds to mitigate bone loss, the field of tissue engineering and regenerative medicine is exploring methods to treat primary and secondary bone malignancies by creating models that mimic the clinical disease manifestation. This Review gives an overview of the preclinical testing in animal models used to evaluate bone regeneration concepts. Immunosuppressed rodent models have shown to be successful in mimicking bone malignancy via the implantation of human-derived cancer cells, whereas large animal models, including pigs, sheep and goats, are being used to provide an insight into bone formation and the effectiveness of scaffolds in induced tibial or femoral defects, providing clinically relevant similarity to human cases. Despite the recent progress, the successful translation of bone regeneration concepts from the bench to the bedside is rooted in the efforts of different research groups to standardise and validate the preclinical models for bone tissue engineering approaches. PMID:29685995
Slaus, Mario; Cicvara-Pećina, Tatjana; Lucijanić, Ivica; Pećina, Marko; Stilinović, Davor
2010-06-01
Although osteochondritis dissecans of the knee has been known for a long time, we still do not fully understand why it develops. This prompted us to present and describe an example of osteochondritis dissecans identified in the Osteological Collection of the Croatian Academy of Sciences and Arts. The case of osteochondritis dissecans described in this report was recovered from the Gluvine kuće cemetery in the Dalmatian hinterland, approximately 28 km north-east of Split. A total of 77 graves were excavated and the individual exhibiting osteochondritis dissecans was recovered from grave number 16 that belongs to the younger phase of the cemetery that lasted during the second half of the 9th century A.D. Osteochondritis dissecans was noted in a subadult individual. The pathological changes consistent with osteochondritis dissecans are present on both medial femoral condyles. The lesion on the right femoral condyle is an oval crater-like defect with well defined margins and a porous floor of rough trabecular bone. The lesion on the left femoral condyle is basically, with two small provisions, identical to the one on the right side. The first is that it is slightly smaller, while the second is that unlike its antimere, it has a well preserved bone fragment that fits perfectly into the ostechondritic pit. Radiographic analyses of the femoral condyles support a diagnosis of osteochondritis dissecans and show a well-demarcated radiolucent defect in the articular surfaces of both joints surrounded by a thin sclerotic repair zone. According to the classification systems this degree of change corresponds to stage 3 or grade 3 osteochondritis dissecans--a detached but non-displaced fragment. Returning, for a second, to the opinion that prompted us to present this case, it is clear that during the last 1100 years there have been no significant morphological or radiological changes in the characteristics of osteochondritis dissecans.
An integrated CAD/CAM/robotic milling method for custom cementless femoral prostheses.
Wen-ming, Xi; Ai-min, Wang; Qi, Wu; Chang-hua, Liu; Jian-fei, Zhu; Fang-fang, Xia
2015-09-01
Aseptic loosening is the primary cause of cementless femoral prosthesis failure and is related to the primary stability of the cementless femoral prosthesis in the femoral cavity. The primary stability affects both the osseointegration and the long-term stability of cementless femoral prostheses. A custom cementless femoral prosthesis can improve the fit and fill of the prosthesis in the femoral cavity and decrease the micromotion of the proximal prosthesis such that the primary stability of the custom prosthesis can be improved, and osseointegration of the proximal prosthesis is achieved. These results will help to achieve long-term stability in total hip arthroplasty (THA). In this paper, we introduce an integrated CAD/CAM/robotic method of milling custom cementless femoral prostheses. The 3D reconstruction model uses femoral CT images and 3D design software to design a CAD model of the custom prosthesis. After the transformation matrices between two units of the robotic system are calibrated, consistency between the CAM software and the robotic system can be achieved, and errors in the robotic milling can be limited. According to the CAD model of the custom prosthesis, the positions of the robotic tool points are produced by the CAM software of the CNC machine. The normal vector of the three adjacent robotic tool point positions determines the pose of the robotic tool point. In conclusion, the fit rate of custom pig femur stems in the femoral cavities was 90.84%. After custom femoral prostheses were inserted into the femoral cavities, the maximum gaps between the prostheses and the cavities measured less than 1 mm at the diaphysis and 1.3 mm at the metaphysis. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Kitamura, Nobuto; Yasuda, Kazunori; Ogawa, Munehiro; Arakaki, Kazunobu; Kai, Shuken; Onodera, Shin; Kurokawa, Takayuki; Gong, Jian Ping
2011-06-01
A double-network (DN) gel, which was composed of poly-(2-acrylamido-2-methylpropanesulfonic acid) and poly-(N,N'-dimetyl acrylamide) (PAMPS/PDMAAm), has the potential to induce chondrogenesis both in vitro and in vivo. To establish the efficacy of a therapeutic strategy for an articular cartilage defect using a DN gel. Controlled laboratory study. A 4.3-mm-diameter osteochondral defect was created in rabbit trochlea. A DN gel plug was implanted into the defect of the right knee so that a defect 2 mm in depth remained after surgery. An untreated defect of the left knee provided control data. The osteochondral defects created were examined by histological and immunohistochemical evaluations, surface assessment using confocal laser scanning microscopy, and real-time polymerase chain reaction (PCR) analysis at 4 and 12 weeks. Samples were quantitatively evaluated with 2 scoring systems reported by Wayne et al and O'Driscoll et al. The DN gel-implanted defect was filled with a sufficient volume of the hyaline cartilage tissue rich in proteoglycan and type 2 collagen. Quantitative evaluation using the grading scales revealed a significantly higher score in the DN gel-implanted defects compared with the untreated control at each period (P < .0001). The mean relative values of type 2 collagen mRNAs in the regenerated tissue were obviously higher in the DN gel-implanted defect than in the untreated control at each period. The mean surface roughness of the untreated control was significantly higher than the normal cartilage at 12 weeks (P = .0106), while there was no statistical difference between the DN gel-implanted and normal knees. This study using the mature rabbit femoral trochlea osteochondral defect model demonstrated that DN gel implantation is an effective treatment to induce cartilage regeneration in vivo without any cultured cells or mammalian-derived scaffolds. This study has prompted us to develop a potential innovative strategy to repair cartilage lesions in the field of joint surgery.
NRC/AMRMC Resident Research Associateship Program
2015-03-01
antimicrobials (and antiseptics) as well as to evaluate the effectiveness of various biofilm dispersal agents utilizing a number of bacterial species as...combat related wounds. 3 Demonstrated the utility of combinations of biofilm dispersal agents and antimicrobials as an alternate therapy for...alone or in combination with antimicrobials ) to reduce infection in contaminated femoral segmental defects. 5 Characterized host responses of
Bonadio, Marcelo B; Friedman, James M; Sennett, Mackenzie L; Mauck, Robert L; Dodge, George R; Madry, Henning
2017-12-01
This study compares a traditional parapatellar retinaculum-sacrificing arthrotomy to a retinaculum-sparing arthrotomy in a porcine stifle joint as a cartilage repair model. Surgical exposure of the femoral trochlea of ten Yucatan pigs stifle joint was performed using either a traditional medial parapatellar approach with retinaculum incision and luxation of the patella (n = 5) or a minimally invasive (MIS) approach which spared the patellar retinaculum (n = 5). Both classical and MIS approaches provided adequate access to the trochlea, enabling the creation of cartilage defects without difficulties. Four full thickness, 4 mm circular full-thickness cartilage defects were created in each trochlea. There were no intraoperative complications observed in either surgical approach. All pigs were allowed full weight-bearing and full range of motion immediately postoperatively and were euthanized between 2 and 3 weeks. The traditional approach was associated with increased cartilage wear compared to the MIS approach. Two blinded raters performed gross evaluation of the trochlea cartilage surrounding the defects according to the modified ICRS cartilage injury classification. The traditional approach cartilage received a significantly worse score than the MIS approach group from both scorers (3.2 vs 0.8, p = 0.01 and 2.8 vs 0, p = 0.005 respectively). The MIS approach results in less damage to the trochlear cartilage and faster return to load bearing activities. As an arthrotomy approach in the porcine model, MIS is superior to the traditional approach.
The effect of hip positioning on the projected femoral neck-shaft angle: a modeling study.
Bhashyam, Abhiram R; Rodriguez, Edward K; Appleton, Paul; Wixted, John J
2018-04-03
The femoral neck-shaft angle (NSA) is used to restore normal hip geometry during hip fracture repair. Femoral rotation is known to affect NSA measurement, but the effect of hip flexion-extension is unknown. The goals of this study were to determine and test mathematical models of the relationship between hip flexion-extension, femoral rotation and NSA. We hypothesized that hip flexion-extension and femoral rotation would result in NSA measurement error. Two mathematical models were developed to predict NSA in varying degrees of hip flexion-extension and femoral rotation. The predictions of the equations were tested in vitro using a model that varied hip flexion-extension while keeping rotation constant, and vice versa. The NSA was measured from an AP radiograph obtained with a C-arm. Attributable measurement error based on hip positioning was calculated from the models. The predictions of the model correlated well with the experimental data (correlation coefficient = 0.82 - 0.90). A wide range of patient positioning was found to result in less than 5-10 degree error in the measurement of NSA. Hip flexion-extension and femoral rotation had a synergistic effect in measurement error of the NSA. Measurement error was minimized when hip flexion-extension was within 10 degrees of neutral. This study demonstrates that hip flexion-extension and femoral rotation significantly affect the measurement of the NSA. To avoid inadvertently fixing the proximal femur in varus or valgus, the hip should be positioned within 10 degrees of neutral flexion-extension with respect to the C-arm to minimize positional measurement error. N/A, basic science study.
Human cartilage repair with a photoreactive adhesive-hydrogel composite.
Sharma, Blanka; Fermanian, Sara; Gibson, Matthew; Unterman, Shimon; Herzka, Daniel A; Cascio, Brett; Coburn, Jeannine; Hui, Alexander Y; Marcus, Norman; Gold, Garry E; Elisseeff, Jennifer H
2013-01-09
Surgical options for cartilage resurfacing may be significantly improved by advances and application of biomaterials that direct tissue repair. A poly(ethylene glycol) diacrylate (PEGDA) hydrogel was designed to support cartilage matrix production, with easy surgical application. A model in vitro system demonstrated deposition of cartilage-specific extracellular matrix in the hydrogel biomaterial and stimulation of adjacent cartilage tissue development by mesenchymal stem cells. For translation to the joint environment, a chondroitin sulfate adhesive was applied to covalently bond and adhere the hydrogel to cartilage and bone tissue in articular defects. After preclinical testing in a caprine model, a pilot clinical study was initiated where the biomaterials system was combined with standard microfracture surgery in 15 patients with focal cartilage defects on the medial femoral condyle. Control patients were treated with microfracture alone. Magnetic resonance imaging showed that treated patients achieved significantly higher levels of tissue fill compared to controls. Magnetic resonance spin-spin relaxation times (T(2)) showed decreasing water content and increased tissue organization over time. Treated patients had less pain compared with controls, whereas knee function [International Knee Documentation Committee (IKDC)] scores increased to similar levels between the groups over the 6 months evaluated. No major adverse events were observed over the study period. With further clinical testing, this practical biomaterials strategy has the potential to improve the treatment of articular cartilage defects.
Patrascu, Jenel M; Krüger, Jan Philipp; Böss, Hademar G; Ketzmar, Anna-Katharina; Freymann, Undine; Sittinger, Michael; Notter, Michael; Endres, Michaela; Kaps, Christian
2013-10-01
In cartilage repair, scaffold-assisted one-step approaches are used to improve the microfracture (Mfx) technique. Since the number of progenitors in Mfx is low and may further decrease with age, aim of our study was to analyze the chondrogenic potential of freeze-dried polyglycolic acid-hyaluronan (PGA-HA) implants preloaded with mesenchymal stem cells (MSCs) in vitro and in a rabbit articular cartilage defect model. Human bone marrow-derived MSC from iliac crest were cultured in freeze-dried PGA-HA implants for chondrogenic differentiation. In a pilot study, implants were loaded with autologous rabbit MSC and used to cover 5 mm × 6 mm full-thickness femoral articular cartilage defects (n = 4). Untreated defects (n = 3) served as controls. Gene expression analysis and histology showed induction of typical chondrogenic marker genes like type II collagen and formation of hyaline-like cartilaginous tissue in MSC-laden PGA-HA implants. Histological evaluation of rabbit repair tissue formation after 30 and 45 days showed formation of repair tissue, rich in chondrocytic cells and of a hyaline-like appearance. Controls showed no articular resurfacing, tissue repair in the subchondral zone and fibrin formation. These results suggest that MSC-laden PGA-HA scaffolds have chondrogenic potential and are a promising option for stem cell-mediated cartilage regeneration. Copyright © 2013 Wiley Periodicals, Inc.
Bardos, Tamas; Farkas, Boglarka; Mezes, Beata; Vancsodi, Jozsef; Kvell, Krisztian; Czompoly, Tamas; Nemeth, Peter; Bellyei, Arpad; Illes, Tamas
2009-11-01
A focal cartilage lesion has limited capacity to heal, and the repair modalities used at present are still unable to provide a universal solution. Pure cartilage graft implantation appears to be a simple option, but it has not been applied widely as cartilage will not reattach easily to the subchondral bone. We used a multiple-incision technique (processed chondrograft) to increase cartilage graft surface. We hypothesized that pure cartilage graft with augmented osteochondral fusion capacity may be used for cartilage repair and we compared this method with other repair techniques. Controlled laboratory study. Full-thickness focal cartilage defects were created on the medial femoral condyle of 9-month-old pigs; defects were repaired using various methods including bone marrow stimulation, autologous chondrocyte implantation, and processed chondrograft. After the repair, at weeks 6 and 24, macroscopic and histologic evaluation was carried out. Compared with other methods, processed chondrograft was found to be similarly effective in cartilage repair. Defects without repair and defects treated with bone marrow stimulation appeared slightly irregular with fibrocartilage filling. Autologous chondrocyte implantation produced hyalinelike cartilage, although its cellular organization was distinguishable from the surrounding articular cartilage. Processed chondrograft demonstrated good osteochondral integration, and the resulting tissue appeared to be hyaline cartilage. The applied cartilage surface processing method allows acceptable osteochondral integration, and the repair tissue appears to have good macroscopic and histologic characteristics. If further studies confirm its efficacy, this technique could be considered for human application in the future.
Stent Coating Integrity of Durable and Biodegradable Coated Drug Eluting Stents.
Yazdani, Saami K; Sheehy, Alexander; Pacetti, Stephen; Rittlemeyer, Brandon; Kolodgie, Frank D; Virmani, Renu
2016-10-01
Coatings consisting of a polymer and drug are widely used in drug-eluting stents (DES) and are essential in providing programmable drug release kinetics. Among other factors, stent coating technologies can influence blood compatibility, affect acute and sub-acute healing, and potentially trigger a chronic inflammatory response. The aim of this study was to investigate the short-term (7 and 28 days) and long-term (90 and 180 days) coating integrity of the Xience Prime Everolimus-Eluting Stent (EES), Resolute Zotarolimus-Eluting Stent (ZES), Taxus Paclitaxel-Eluting Stent (PES), and Nobori Biolimus A9-Eluting Stent (BES) in a rabbit ilio-femoral stent model. Stented arteries (n = 48) were harvested and the tissue surrounding the implanted stents digested away with an enzymatic solution. Results demonstrated that the majority of struts of EES were without any coating defects with a few struts showing minor defects. Similarly, for the ZES, most of the struts were without coating defects at all time points except at 180 days. The majority of PES demonstrated mostly webbing and uneven coating. In the BES group, the majority of strut coating showed polymer cracking. Overall, the EES and ZES had fewer coating defects than the PES and BES. Coating defects, however increase over time for the ZES, whereas the percent of coating irregularities remained constant for the EES. These results provide, for the first time, a comparison of the long-term durability of these drug-eluting stent coatings in vivo. © 2016, Wiley Periodicals, Inc.
Management of complex femoral nonunion with monorail external fixator: A prospective study.
Agrawal, Hemendra Kumar; Garg, Mohit; Singh, Balvinder; Jaiman, Ashish; Khatkar, Vipin; Khare, Shailender; Batra, Sumit; Sharma, Vinod Kumar
2016-01-01
To evaluate 30 patients who underwent distraction osteogenesis with monorail external fixator for complex femoral nonunion. Complex femoral nonunion includes infective non-union, gap nonunion, and limb-length discrepancy secondary to traumatic bone loss, which needs specialized treatment to ensure the functional integrity of femoral bone. 30 patients, including 28 male and 2 female (aged 22-62 years) patients, underwent surgical debridement followed by bone transport with monorail fixator. The lengthening index, radiographic consolidation index, functional status, bone healing, and various problems, obstacles, and complications encountered during the treatment were assessed. Patients underwent a mean of 2.2 (range 1-4) surgeries before presentation. The mean bone defect after surgical debridement was 5.83 cm (range 2-16 cm). The mean treatment duration was 204.7 days (range 113-543 days). The mean lengthening index was 13.06 days/cm with range from 12 to 16 days/cm. Mean maturation index was 23.51 days/cm with range from 17 to 45.5 days/cm. In our study, bone result was excellent in 17, good in 9, fair in 3, and poor in 1 patient. In our study functional outcome is excellent in 9 [30%], good in 14 [46.67%], fair in 5, and poor in 2 patients. In our study, we encountered 34 problems, 17 obstacles, and 8 complications. We concluded that monorail external fixator is an effective treatment option for complex nonunion femoral shaft fracture and its functional outcome is comparable with any other treatment options. Lack of complications and its effectiveness makes monorail external fixator the treatment of choice for complex nonunion femoral shaft.
Onishi, Tadanobu; Shimizu, Takamasa; Omokawa, Shohei; Sananpanich, Kanit; Kido, Akira; Mahakkanukrauh, Pasuk; Tanaka, Yasuhito
2018-05-30
There is lack of anatomical information regarding cutaneous perforator of the popliteal artery and its connections with the descending branch of the inferior gluteal and profunda femoris arteries. We aimed to evaluate the anatomical basis of popliteal artery perforator-based propeller flap from the posterior thigh region and to demonstrate our experience utilizing this flap. Ten fresh cadaveric lower extremities were dissected following injection of a silicone compound into the femoral artery. We investigated the number, location, length, and diameter of cutaneous perforators of the popliteal artery. Based on the results, we treated three cases with a large soft tissue defect around the knee using popliteal artery perforator-based propeller flap. We found a mean of 1.9 cutaneous perforators arising from the popliteal artery with a mean pedicle length of 6 cm and a mean arterial internal diameter of 0.9 mm, which were located at an average of 4 cm proximal to the bicondylar line. The most distal perforator consistently arose along the small saphenous vein and connected proximally with concomitant artery of the posterior femoral cutaneous nerve, forming a connection with perforating arteries of the profunda femoris artery. A mean of 4.5 cutaneous perforators branched from the arterial connection sites. All clinical cases healed without any complications. The popliteal artery perforator-based propeller flap is reliable for reconstruction of soft tissue defects around the knee. The flap should include the deep fascia and concomitant artery along with the posterior femoral cutaneous nerve for maintaining the blood supply.
Haishima, Yuji; Hasegawa, Chie; Todoki, Kazuo; Sasaki, Kazuo; Niimi, Shingo; Ozono, Satoru
2017-08-01
The purpose of this study was to accurately quantify the risk of endotoxin contamination in biomaterials for bone regeneration in order to establish the acceptable endotoxin limit. Collagen sheets containing varying amounts of purified endotoxin from Escherichia coli and dried, heat-killed E. coli or Staphylococcus aureus cells were implanted into cranial or femoral defects in rats. These defects were artificially prepared to a size of 5 × 5 mm or a diameter of 1 mm, respectively. The degree of osteoanagenesis was assessed by soft X-ray radiography and histopathology at 1 and 4 weeks after implantation. The collagen sheet containing the dried E. coli cells showed a dose-dependent delay in cranial and/or femoral osteoanagenesis at endotoxin activities of more than 33.6 EU/mg, at which no inflammatory response was observed. In contrast, no such observation occurred with the collagen sheet containing S. aureus cells. These results suggest that endotoxins may affect the process of osteoanagenesis. Additionally, the no-observed-adverse-effect level was 9.6 EU/mg, corresponding to 255 EU/kg body weight in rats. Interestingly, no delay in osteoanagenesis was induced by the implantation of collagen sheets containing purified endotoxin at any dose tested. This suggested that pure endotoxin implanted into tissues having poor circulation of bodily fluids without bleeding may not be recognized as a foreign substance and may not induce a significant biological response. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1514-1524, 2017. © 2016 Wiley Periodicals, Inc.
O'Connell, Kathleen; Pierlot, Caitlin; O'Shea, Helen; Beaudry, Diane; Chagnon, Madeleine; Assad, Michel; Boyd, Daniel
2017-10-01
Borate glasses have shown promising potential as bioactive materials. With recent research demonstrating that glass properties may be modulated by appropriate compositional design. This may provide for indication specific material characteristics and controlled release of therapeutic inorganic ions (i.e., strontium); controlling such release is critical in order to harness the therapeutic potential. Within this sub-chronic pilot study, a rabbit long-bone model was utilized to explore the safety and efficacy of a high borate glass (LB102: 70B 2 O 3 -20SrO-6Na 2 O-4La 2 O 3 ) particulate (90 - 710 μm) for bone regeneration. Six bilateral full-thickness defects (Ø = 3.5 mm; L = 8 mm) were created in three white New Zealand rabbits. Longitudinal non-decalcified sections of each defect site were produced and stained with Goldner's Trichrome. Histopathological examination revealed that LB102 demonstrated osteoconductive and osseointegrative properties with greater new bone being formed within and surrounding LB102 particles, when compared to the sham control. The inflammatory cell infiltration was observed to be slightly higher in the control when compared to LB102 defect sites, while no significant difference in fibrosis and neovascularization was determined, indicating that healing was occurring in a normal fashion. These data further suggest the possible utility of high borate glasses with appropriate compositional design for medical applications, such as bone augmentation. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1818-1827, 2017. © 2016 Wiley Periodicals, Inc.
Jia, Yanhui; Yuan, Mei; Guo, Weimin; Huang, Jingxiang; Zhao, Bin; Xu, Wenjing; Lu, Shibi
2017-01-01
Umbilical cord Wharton's jelly-derived mesenchymal stem cell (WJMSC) is a new-found mesenchymal stem cell in recent years with multiple lineage potential. Due to its abundant resources, no damage procurement, and lower immunogenicity than other adult MSCs, WJMSC promises to be a good xenogenous cell candidate for tissue engineering. This in vivo pilot study explored the use of human umbilical cord Wharton's jelly mesenchymal stem cells (hWJMSCs) containing a tissue engineering construct xenotransplant in rabbits to repair full-thickness cartilage defects in the femoral patellar groove. We observed orderly spatial-temporal remodeling of hWJMSCs into cartilage tissues during repair over 16 months, with characteristic architectural features, including a hyaline-like neocartilage layer with good surface regularity, complete integration with adjacent host cartilage, and regenerated subchondral bone. No immune rejection was detected when xenograft hWJMSCs were implanted into rabbit cartilage defects. The repair results using hWJMSCs were superior to those of chondrogenically induced hWJMSCs after assessing gross appearance and histological grading scores. These preliminary results suggest that using novel undifferentiated hWJMSCs as seed cells might be a better approach than using transforming growth factor-β-induced differentiated hWJMSCs for in vivo tissue engineering treatment of cartilage defects. hWJMSC allografts may be promising for clinical applications. PMID:28261617
Liu, Hongwei; Weng, Yiping; Zhang, Yunkun; Xu, Nanwei; Tong, Jing; Wang, Caimei
2015-09-01
To study the feasibility of preparation of the individualized femoral prosthesis through computer assisted design and electron beammelting rapid prototyping (EBM-RP) metal three-dimensional (3D) printing technology. One adult male left femur specimen was used for scanning with 64-slice spiral CT; tomographic image data were imported into Mimics15.0 software to reconstruct femoral 3D model, then the 3D model of individualized femoral prosthesis was designed through UG8.0 software. Finally the 3D model data were imported into EBM-RP metal 3D printer to print the individualized sleeve. According to the 3D model of individualized prosthesis, customized sleeve was successfully prepared through the EBM-RP metal 3D printing technology, assembled with the standard handle component of SR modular femoral prosthesis to make the individualized femoral prosthesis. Customized femoral prosthesis accurately matching with metaphyseal cavity can be designed through the thin slice CT scanning and computer assisted design technology. Titanium alloy personalized prosthesis with complex 3D shape, pore surface, and good matching with metaphyseal cavity can be manufactured by the technology of EBM-RP metal 3D printing, and the technology has convenient, rapid, and accurate advantages.
Han, Rui; Geng, Chengkui; Wang, Yongnian; Wei, Lei
2008-01-01
The objective of this research was to induce a new animal model of osteonecrosis of the femoral head (ONFH) by microwave heating and then repair with tissue engineered bone. The bilateral femoral heads of 84 rabbits were heated by microwave at various temperatures. Tissue engineered bone was used to repair the osteonecrosis of femoral heads induced by microwave heating. The roentgenographic and histological examinations were used to evaluate the results. The femoral heads heated at 55°C for ten minutes showed low density and cystic changes in X-ray photographs, osteonecrosis and repair occurred simultaneously in histology at four and eight weeks, and 69% femoral heads collapsed at 12 weeks. The ability of tissue engineered bone to repair the osteonecrosis was close to that of cancellous bone autograft. The new animal model of ONFH could be induced by microwave heating, and the tissue engineering technique will provide an effective treatment. PMID:18956184
Human Urine Derived Stem Cells in Combination with β-TCP Can Be Applied for Bone Regeneration.
Guan, Junjie; Zhang, Jieyuan; Li, Haiyan; Zhu, Zhenzhong; Guo, Shangchun; Niu, Xin; Wang, Yang; Zhang, Changqing
2015-01-01
Bone tissue engineering requires highly proliferative stem cells that are easy to isolate. Human urine stem cells (USCs) are abundant and can be easily harvested without using an invasive procedure. In addition, in our previous studies, USCs have been proved to be able to differentiate into osteoblasts, chondrocytes, and adipocytes. Therefore, USCs may have great potential and advantages to be applied as a cell source for tissue engineering. However, there are no published studies that describe the interactions between USCs and biomaterials and applications of USCs for bone tissue engineering. Therefore, the objective of the present study was to evaluate the interactions between USCs with a typical bone tissue engineering scaffold, beta-Tricalcium Phosphate (β-TCP), and to determine whether the USCs seeded onto β-TCP scaffold can promote bone regeneration in a segmental femoral defect of rats. Primary USCs were isolated from urine and seeded on β-TCP scaffolds. Results showed that USCs remained viable and proliferated within β-TCP. The osteogenic differentiation of USCs within the scaffolds was demonstrated by increased alkaline phosphatase activity and calcium content. Furthermore, β-TCP with adherent USCs (USCs/β-TCP) were implanted in a 6-mm critical size femoral defect of rats for 12 weeks. Bone regeneration was determined using X-ray, micro-CT, and histologic analyses. Results further demonstrated that USCs in the scaffolds could enhance new bone formation, which spanned bone defects in 5 out of 11 rats while β-TCP scaffold alone induced modest bone formation. The current study indicated that the USCs can be used as a cell source for bone tissue engineering as they are compatible with bone tissue engineering scaffolds and can stimulate the regeneration of bone in a critical size bone defect.
Nelson, Brad B; Kawcak, Chris E; Goodrich, Laurie R; Werpy, Natasha M; Valdés-Martínez, Alejandro; McIlwraith, C Wayne
2016-07-01
The femorotibial joints are a common source of lameness in Western performance horses. The objective of this prospective study was to compare the radiography, ultrasonography, computed tomographic arthrography (CTA), and arthroscopy findings in horses with lameness localized to the femorotibial joints. Twenty-five stifles in 24 horses were included and were evaluated with all four of these diagnostic methods. Defects detected in femorotibial joint structures were compared between diagnostic methods using a McNemar's test to evaluate for disagreement. Cranial medial meniscotibial desmopathy was most detected on arthroscopy (in 14/25 cases) and was only detected on ultrasonography in three out of 11 (27.3%) arthroscopically observed cases, but was detected on CTA in nine out of 12 (75%) arthroscopically observed cases. Medial meniscal injury located on the craniolateral border was most detected on arthroscopy (n = 9) and was detected on CTA in five cases, but on ultrasonography in 0 cases. Detection of articular cartilage defects on the medial femoral condyle was most detected with arthroscopy (24/25, 96% cases) and was also detected on CTA in 12/20 (60%) cases with a significant disagreement identified between modalities (P = 0.02). Cranial and caudal cruciate ligament defects were detected on CTA in 6/22 (27.3%) and 7/19 (36.8%) cases, respectively, and with arthroscopy in 3/25 (12%) and 2/25 (8%) cases, respectively. The use of CTA detected more defects in the cruciate ligaments, proximal tibia, and ligament entheses than the other diagnostic methods, but was not reliable for detection of articular cartilage damage on the medial femoral condyle. © 2016 American College of Veterinary Radiology.
Computational Modelling of Patella Femoral Kinematics During Gait Cycle and Experimental Validation
NASA Astrophysics Data System (ADS)
Maiti, Raman
2016-06-01
The effect of loading and boundary conditions on patellar mechanics is significant due to the complications arising in patella femoral joints during total knee replacements. To understand the patellar mechanics with respect to loading and motion, a computational model representing the patella femoral joint was developed and validated against experimental results. The computational model was created in IDEAS NX and simulated in MSC ADAMS/VIEW software. The results obtained in the form of internal external rotations and anterior posterior displacements for a new and experimentally simulated specimen for patella femoral joint under standard gait condition were compared with experimental measurements performed on the Leeds ProSim knee simulator. A good overall agreement between the computational prediction and the experimental data was obtained for patella femoral kinematics. Good agreement between the model and the past studies was observed when the ligament load was removed and the medial lateral displacement was constrained. The model is sensitive to ±5 % change in kinematics, frictional, force and stiffness coefficients and insensitive to time step.
Computational Modelling of Patella Femoral Kinematics During Gait Cycle and Experimental Validation
NASA Astrophysics Data System (ADS)
Maiti, Raman
2018-06-01
The effect of loading and boundary conditions on patellar mechanics is significant due to the complications arising in patella femoral joints during total knee replacements. To understand the patellar mechanics with respect to loading and motion, a computational model representing the patella femoral joint was developed and validated against experimental results. The computational model was created in IDEAS NX and simulated in MSC ADAMS/VIEW software. The results obtained in the form of internal external rotations and anterior posterior displacements for a new and experimentally simulated specimen for patella femoral joint under standard gait condition were compared with experimental measurements performed on the Leeds ProSim knee simulator. A good overall agreement between the computational prediction and the experimental data was obtained for patella femoral kinematics. Good agreement between the model and the past studies was observed when the ligament load was removed and the medial lateral displacement was constrained. The model is sensitive to ±5 % change in kinematics, frictional, force and stiffness coefficients and insensitive to time step.
NRC/AMRMC Resident Research Associateship Program
2015-03-01
antimicrobials (and antiseptics) as well as to evaluate the effectiveness of various biofilm dispersal agents utilizing a number of bacterial species as well...combat related wounds. 3 Demonstrated the utility of combinations of biofilm dispersal agents and antimicrobials as an alternate therapy for targeting...alone or in combination with antimicrobials ) to reduce infection in contaminated femoral segmental defects. 5 Characterized host responses of
Sasaki, T.; Akagi, R.; Akatsu, Y.; Fukawa, T.; Hoshi, H.; Yamamoto, Y.; Enomoto, T.; Sato, Y.; Nakagawa, R.; Takahashi, K.; Yamaguchi, S.
2017-01-01
Objectives The aim of this study was to investigate the effect of granulocyte-colony stimulating factor (G-CSF) on mesenchymal stem cell (MSC) proliferation in vitro and to determine whether pre-microfracture systemic administration of G-CSF (a bone marrow stimulant) could improve the quality of repaired tissue of a full-thickness cartilage defect in a rabbit model. Methods MSCs from rabbits were cultured in a control medium and medium with G-CSF (low-dose: 4 μg, high-dose: 40 μg). At one, three, and five days after culturing, cells were counted. Differential potential of cultured cells were examined by stimulating them with a osteogenic, adipogenic and chondrogenic medium. A total of 30 rabbits were divided into three groups. The low-dose group (n = 10) received 10 μg/kg of G-CSF daily, the high-dose group (n = 10) received 50 μg/kg daily by subcutaneous injection for three days prior to creating cartilage defects. The control group (n = 10) was administered saline for three days. At 48 hours after the first injection, a 5.2 mm diameter cylindrical osteochondral defect was created in the femoral trochlea. At four and 12 weeks post-operatively, repaired tissue was evaluated macroscopically and microscopically. Results The cell count in the low-dose G-CSF medium was significantly higher than that in the control medium. The differentiation potential of MSCs was preserved after culturing them with G-CSF. Macroscopically, defects were filled and surfaces were smoother in the G-CSF groups than in the control group at four weeks. At 12 weeks, the quality of repaired cartilage improved further, and defects were almost completely filled in all groups. Microscopically, at four weeks, defects were partially filled with hyaline-like cartilage in the G-CSF groups. At 12 weeks, defects were repaired with hyaline-like cartilage in all groups. Conclusions G-CSF promoted proliferation of MSCs in vitro. The systemic administration of G-CSF promoted the repair of damaged cartilage possibly through increasing the number of MSCs in a rabbit model. Cite this article: T. Sasaki, R. Akagi, Y. Akatsu, T. Fukawa, H. Hoshi, Y. Yamamoto, T. Enomoto, Y. Sato, R. Nakagawa, K. Takahashi, S. Yamaguchi, T. Sasho. The effect of systemic administration of G-CSF on a full-thickness cartilage defect in a rabbit model MSC proliferation as presumed mechanism: G-CSF for cartilage repair. Bone Joint Res 2017;6:123–131. DOI: 10.1302/2046-3758.63.BJR-2016-0083. PMID:28258115
von Engelhardt, Lars Victor; El Tabbakh, Mohammed Roshdy; Engers, Rainer; Lahner, Matthias; Jerosch, Jörg
2016-11-14
Osteoid osteoma is an osteoblastic benign bone tumor usually affecting young adolescents. Intra-articular lesions are not common; usually the diagnosis is delayed. A lot of studies report difficulties and complications in the management of osteoid osteoma of the hip joint using imaging guided techniques or open surgical procedures. Only few published cases have described that it can be treated precisely using hip arthroscopy. Additionally, the use of hip arthroscopy to apply the Chondrofiller®, an acellular collagen matrix for the management of articular cartilage defects of the hip joint, has not yet been described. This report presents an osteoid osteoma of the femoral neck. A 20-year-old female professional basketball player presented with pain in the left groin since more than 12 months. On magnetic resonance and computed tomography imaging, an osteoid osteoma was suggested. The lesion was successfully removed using arthroscopy. During surgery, a concomitant grade 4 cartilage lesion on the femoral head was detected. For the treatment of this severe defect we used the Chondrofiller®, which is a new acellular collagen implant for auto-regeneration of articular cartilage. This matrix was filled into the prepared and dried defect using CO2 arthroscopy. After the hardening of the matrix the surgery was finished. The patient was pain free shortly after the operation and returned to sports within 16 weeks. Return to high-performance sports 8 months after surgery was without of any sign of complaints. This article demonstrates that hip arthroscopy is a valuable tool for biopsy and excision of intra-articular osteoid osteoma affecting the hip joint, as well as for addressing other concomitant pathologies such as a severe synovitis or cartilage defects. CO2 arthroscopy provided good conditions for the drying and filling of the cartilage defect with the Chondrofiller®.
Li, Xue; Xu, Chang-peng; Cui, Zhuang; Jiang, Nan; Jia, Jun-jie; Yu, Bin
2014-01-01
Objective Current medical practice for the treatment of articular cartilage lesions remains a clinical challenge due to the limited self-repair ability of articular cartilage. Both experimental and clinical researches show that moderate exercise can improve articular cartilage repair process. However, optimal timing of moderate exercise is unclear. We aimed to evaluate the effect of timing of moderate treadmill exercise on repair of full-thickness defects of articular cartilage. Design Full-thickness cartilage defects were drilled in the patellar groove of bilateral femoral condyles in a total of 40 male SD rats before they were randomly assigned into four even groups. In sedentary control (SED) group, no exercise was given; in 2-week (2W), 4-week (4W) and 8-week groups, moderate treadmill exercise was initiated respectively two, four and eight weeks after operation. Half of the animals were sacrificed at week 10 after operation and half at week 14 after operation. Femoral condyles were harvested for gross observation and histochemical measurement by O'Driscoll scoring system. Collagen type II was detected by immunohistochemistry and mRNA expressions of aggrecan and collagen type II cartilage by RT-PCR. Results Both 10 and 14 weeks post-operation, the best results were observed in 4W group and the worst results appeared in 2W group. The histochemistry scores and the expressions of collagen type II and aggrecan were significantly higher in 4W group than that in other three groups (P<0.05). Conclusions Moderate exercise at a selected timing (approximately 4 weeks) after injury can significantly promote the healing of cartilage defects but may hamper the repair process if performed too early while delayed intervention by moderate exercise may reduce its benefits in repair of the defects. PMID:24595327
[Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis].
Medenica, Ivica; Luković, Milan; Radoicić, Dragan
2010-02-01
The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score--7.1). We performed total rearthroplasty by a custom-made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score--87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specificaly for a patient) and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.
Duan, Hong; Yang, Hongsheng; Xiong, Yan; Zhang, Bin; Ren, Cheng; Min, Li; Zhang, Wenli; Yan, Yonggang; Li, Hong; Pei, Fuxing; Tu, Chongqi
2013-01-01
Background and methods Guided bone regeneration (GBR) is a new treatment for bone defects, and the property of membrane is critical to the success of GBR. This study focuses on a novel membrane tube for GBR, which was prepared by a nanocalcium-deficient hydroxyapatite–multi(amino acid) copolymer (n-CDHA-MAC) composite. The biomechanical strength and degradability of this membrane tube under mechanical loading after immersion in phosphate-buffered solution were investigated to evaluate the effects of mechanical loading on the membrane tube. The membrane-tube group with no mechanical loading and femora bone were used as controls. Results The compressive strength and bending strength of n-CDHA-MAC membrane tubes were 66.4 ± 10.2 MPa and 840.7 ± 12.1 MPa, which were lower than those of the goats’ femoral bones (69.0 ± 5.5 MPa and 900.2 ± 17.3 MPa), but there were no significant (P > 0.05) differences. In the in vitro degradability experiment, all membrane tubes were degradable and showed a surface-erosion degradation model. The PH of solution fluctuated from 7.2 to 7.5. The weight and mechanical strength of loaded tubes decreased more quickly than nonloaded ones, with significant differences (P < 0.05). However, the strength of the loaded group after degradation achieved 20.4 ± 1.2 MPa, which was greater than the maximum mechanical strength of 4.338 MPa based on goat femoral middle stationary state by three-dimensional finite-element analysis. Conclusions n-CDHA-MAC membrane tubes have good biomechanical strength during degradation under mechanical loading. Therefore, this membrane tube is an ideal GBR membrane for critical size defects of long bones in goats for animal experiments. PMID:23946651
Gagala, J; Tarczynska, M; Gaweda, K; Matuszewski, L
2014-09-01
Osteonecrosis of the femoral head is an entity which occurs mainly in young and active patients aged between 20 and 50. The success of hip joint preserving treatments ranges from 15% to 50% depending on the stage and amount of osteonecrotic lesion. Total hip replacement is indicated in late post-collapse hips but it has unsatisfactory survival because of the wear and osteolysis in young and active patients. Osteochondral allografts have been reported in the treatment of large articular lesions with defects in underlying bone in knee, talus and shoulder. By combining osteoconductive properties of osteochondral allograft with osteogenic abilities of bone marrow-derived mesenchymal cells it has a potential to be an alternative to an autologous graft. The adjunct of hinged joint distraction should minimize stresses in subchondral bone to promote creeping substitution and prevent femoral head collapse. Unlike current treatment modalities, it would provide both structural support and allow bony and articular substitution. Copyright © 2014 Elsevier Ltd. All rights reserved.
A three-dimensional axis for the study of femoral neck orientation
Bonneau, Noémie; Libourel, Paul-Antoine; Simonis, Caroline; Puymerail, Laurent; Baylac, Michel; Tardieu, Christine; Gagey, Olivier
2012-01-01
A common problem in the quantification of the orientation of the femoral neck is the difficulty to determine its true axis; however, this axis is typically estimated visually only. Moreover, the orientation of the femoral neck is commonly analysed using angles that are dependent on anatomical planes of reference and only quantify the orientation in two dimensions. The purpose of this study is to establish a method to determine the three-dimensional orientation of the femoral neck using a three-dimensional model. An accurate determination of the femoral neck axis requires a reconsideration of the complex architecture of the proximal femur. The morphology of the femoral neck results from both the medial and arcuate trabecular systems, and the asymmetry of the cortical bone. Given these considerations, two alternative models, in addition to the cylindrical one frequently assumed, were tested. The surface geometry of the femoral neck was subsequently used to fit one cylinder, two cylinders and successive cross-sectional ellipses. The model based on successive ellipses provided a significantly smaller average deviation than the two other models (P < 0.001) and reduced the observer-induced measurement error. Comparisons with traditional measurements and analyses on a sample of 91 femora were also performed to assess the validity of the model based on successive ellipses. This study provides a semi-automatic and accurate method for the determination of the functional three-dimensional femoral neck orientation avoiding the use of a reference plane. This innovative method has important implications for future studies that aim to document and understand the change in the orientation of the femoral neck associated with the acquisition of a bipedal gait in humans. Moreover, the precise determination of the three-dimensional orientation has implications in current research involved in developing clinical applications in diagnosis, hip surgery and rehabilitation. PMID:22967192
Evaluating the relationship between muscle and bone modeling response in older adults.
Reider, Lisa; Beck, Thomas; Alley, Dawn; Miller, Ram; Shardell, Michelle; Schumacher, John; Magaziner, Jay; Cawthon, Peggy M; Barbour, Kamil E; Cauley, Jane A; Harris, Tamara
2016-09-01
Bone modeling, the process that continually adjusts bone strength in response to prevalent muscle-loading forces throughout an individual's lifespan, may play an important role in bone fragility with age. Femoral stress, an index of bone modeling response, can be estimated using measurements of DXA derived bone geometry and loading information incorporated into an engineering model. Assuming that individuals have adapted to habitual muscle loading forces, greater stresses indicate a diminished response and a weaker bone. The purpose of this paper was to evaluate the associations of lean mass and muscle strength with the femoral stress measure generated from the engineering model and to examine the extent to which lean mass and muscle strength account for variation in femoral stress among 2539 healthy older adults participating in the Health ABC study using linear regression. Mean femoral stress was higher in women (9.51, SD=1.85Mpa) than in men (8.02, SD=1.43Mpa). Percent lean mass explained more of the variation in femoral stress than did knee strength adjusted for body size (R(2)=0.187 vs. 0.055 in men; R(2)=0.237 vs. 0.095 in women). In models adjusted for potential confounders, for every percent increase in lean mass, mean femoral stress was 0.121Mpa lower (95% CI: -0.138, -0.104; p<0.001) in men and 0.139Mpa lower (95% CI: -0.158, -0.121; p<0.001) in women. The inverse association of femoral stress with lean mass and with knee strength did not differ by category of BMI. Results from this study provide insight into bone modeling differences as measured by femoral stress among older men and women and indicate that lean mass may capture elements of bone's response to load. Copyright © 2016 Elsevier Inc. All rights reserved.
Unexpected angular or rotational deformity after corrective osteotomy
2014-01-01
Background Codman’s paradox reveals a misunderstanding of geometry in orthopedic practice. Physicians often encounter situations that cannot be understood intuitively during orthopedic interventions such as corrective osteotomy. Occasionally, unexpected angular or rotational deformity occurs during surgery. This study aimed to draw the attention of orthopedic surgeons toward the concepts of orientation and rotation and demonstrate the potential for unexpected deformity after orthopedic interventions. This study focused on three situations: shoulder arthrodesis, femoral varization derotational osteotomy, and femoral derotation osteotomy. Methods First, a shoulder model was generated to calculate unexpected rotational deformity to demonstrate Codman’s paradox. Second, femoral varization derotational osteotomy was simulated using a cylinder model. Third, a reconstructed femoral model was used to calculate unexpected angular or rotational deformity during femoral derotation osteotomy. Results Unexpected external rotation was found after forward elevation and abduction of the shoulder joint. In the varization and derotation model, closed-wedge osteotomy and additional derotation resulted in an unexpected extension and valgus deformity, namely, under-correction of coxa valga. After femoral derotational osteotomy, varization and extension of the distal fragment occurred, although the extension was negligible. Conclusions Surgeons should be aware of unexpected angular deformity after surgical procedure involving bony areas. The degree of deformity differs depending on the context of the surgical procedure. However, this study reveals that notable deformities can be expected during orthopedic procedures such as femoral varization derotational osteotomy. PMID:24886469
Zhang, Liyan; Sun, Xin; Tian, Dan; Xu, Rui; Lei, Hao; Al, Jinhui; Zhao, Bo; Chen, Jiying; Chai, Wei; Ma, Shoucheng; Liu, Weijia; Shen, Siyuan
2015-10-01
To establish an rabbit model of early steroid-induced avascular necrosis of the femoral head (SANFH) and evaluate its validity with MRI and pathological examination. Twenty 6-month-old rabbits (weighing, 2-3 kg) were randomly divided into 2 groups (control group and model group), 10 rabbits in each group. Dexamethasone sodium phosphate solution (10 mg/kg) was injected into bilateral gluteus in model group, and the same amount of saline was injected in control group, every 3 days for 14 times. General observation was done after modelling. Osteonecrosis was verified by pathological observation and MRI findings at 6 weeks. After 6 weeks, rabbits did not show obvious changes in control group; increased hair removal, decreased food intake, and slight limp were observed in model group. The MRI results showed normal shape of the bilateral femoral head and no abnormal signals in control group; irregular shape of the bilateral femoral head and a slice of irregular abnormal signals were observed, and necrosis and cystolization of the subchondral bone and sparse changes of trabecular bone were shown in model group. General observation from coronal section of femoral head showed smooth red cartilage surface in control group; on the contrary, the cartilage surface of the femoral head became dull, thin even visible hemorrhage under articular cartilage and necrosis of the femoral head were observed. The histopathological examination indicated that trabecular bone of the femoral head in control group was massive, thick, and close and osteocytes in the bone lacunae had normal shapes. The osseous trabecular became thinner and broken; karyopyknosis of osteocytes and bone empty lacunae could be obviously seen in model. group. The rates of empty lacunae were 8.0% ± 0.5% in control group and 49.0% ± 0.3% in model group, showing significant difference (t = 21.940, P = 0.000). Establishing a model of early SANFH through injecting short-term, shock, and high dose of dexamethasone, and it can been evaluated effectively with MRI and pathological examination.
Hip Resurfacing Using Highly Cross-linked Polyethylene: Prospective Study Results at 8.5 Years.
Pritchett, James W
2016-10-01
Hip resurfacing is an option to consider when treating younger, more active patients. Advantages over total hip arthroplasty include a more normal gait and a lower incidence of thigh pain. In this prospective study, 190 hip resurfacing procedures (164 participants) were performed using a cobalt-chromium femoral component and a cementless acetabular cup with a 3.8-mm highly cross-linked polyethylene acetabular liner. The mean follow-up was 8.5 (range, 7-10) years. Two participants were lost to follow-up and 2 died. One participant underwent successful revision surgery for acetabular loosening. Four participants underwent successful revision to a total hip arthroplasty because of femoral neck fracture (2), femoral loosening, or infection. The Kaplan-Meier survivorship was 97%. Acetabular bone conservation was assessed using computed tomography by measuring the medial acetabular wall. The mean thickness was 9 mm. Femoral bone was well preserved with a mean head:neck ratio of 1.37. There were 4 (2%) osteolytic defects up to 0.9 cm(3) on computed tomography and no instances of impending polyethylene wear-through. Seven polyethylene retrievals had a measured wear rate of 0.05 mm/y. Hip resurfacing using a highly cross-linked polyethylene acetabular component is a reliable procedure. Both femoral and acetabular bones are reasonably preserved compared with prior resurfacing methods. The low incidence of osteolysis and the low rate of wear found on retrievals suggest that many years of use in highly active patients is possible. Copyright © 2016 Elsevier Inc. All rights reserved.
Abdullah, Abdul Halim; Todo, Mitsugu; Nakashima, Yasuharu
2017-06-01
Femoral bone fracture is one of the main causes for the failure of hip arthroplasties (HA). Being subjected to abrupt and high impact forces in daily activities may lead to complex loading configuration such as bending and sideway falls. The objective of this study is to predict the risk of femoral bone fractures in total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA). A computed tomography (CT) based on finite element analysis was conducted to demonstrate damage formation in a three dimensional model of HAs. The inhomogeneous model of femoral bone was constructed from a 79 year old female patient with hip osteoarthritis complication. Two different femoral components were modeled with titanium alloy and cobalt chromium and inserted into the femoral bones to present THA and RHA models respectively. The analysis included six configurations, which exhibited various loading and boundary conditions, including axial compression, torsion, lateral bending, stance and two types of falling configurations. The applied hip loadings were normalized to body weight (BW) and accumulated from 1 BW to 3 BW. Predictions of damage formation in the femoral models were discussed as the resulting tensile failure as well as the compressive yielding and failure elements. The results indicate that loading directions can forecast the pattern and location of fractures at varying magnitudes of loading. Lateral bending configuration experienced the highest damage formation in both THA and RHA models. Femoral neck and trochanteric regions were in a common location in the RHA model in most configurations, while the predicted fracture locations in THA differed as per the Vancouver classification. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Marra, Marco A; Strzelczak, Marta; Heesterbeek, Petra J C; van de Groes, Sebastiaan A W; Janssen, Dennis; Koopman, Bart F J M; Verdonschot, Nico; Wymenga, Ate B
2018-03-20
When downsizing the femoral component to prevent mediolateral overhang, notching of the anterior femoral cortex may occur, which could be solved by flexing the femoral component. In this study, we investigated the effect of flexion of the femoral component on patellar tendon moment arm, patellofemoral forces and kinematics in posterior-referencing CR-TKA. Our hypothesis was that flexion of the femoral component increases the patellar tendon moment arm, reduces the patellofemoral forces and provides stable kinematics. A validated musculoskeletal model of CR-TKA was used. The flexion of the femoral component was increased in four steps (0°, 3°, 6°, 9°) using posterior referencing, and different alignments were analysed in combination with three implant sizes (3, 4, 5). A chair-rising trial was analysed using the model, while simultaneously estimating quadriceps muscle force, patellofemoral contact force, tibiofemoral and patellofemoral kinematics. Compared to the reference case (size 4 and 0° flexion), for every 3° of increase in flexion of the femoral component the patellar tendon moment arm increased by 1% at knee extension. The peak quadriceps muscle force and patellofemoral contact force decreased by 2%, the patella shifted 0.8 mm more anteriorly and the remaining kinematics remained stable, with knee flexion. With the smaller size, the patellar tendon moment arm decreased by 6%, the quadriceps muscle force and patellofemoral contact force increased by 8 and 12%, and the patellar shifted 5 mm more posteriorly. Opposite trends were found with the bigger size. Flexing the femoral component with posterior referencing reduced the patellofemoral contact forces during a simulated chair-rising trial with a patient-specific musculoskeletal model of CR-TKA. There seems to be little risk when flexing and downsizing the femoral component, compared to when using a bigger size and neutral alignment. These findings provide relevant information to surgeons who wish to prevent anterior notching when downsizing the femoral component.
2014-10-03
frac tures? J Orthop Res 29, 33, 2011. Epub 2010/07/08. 2. Russell, T.A., and Leighton , R.K. Comparison of autogenous bone graft and endothermic...Boyd, S.K., Christiansen , B.A., Guldberg, R.E., Jepsen, K.J., and Muller, R. Guidelines for assessment of bone microstructure in rodents using micro
Hingorani, Anil P; Ascher, Enrico; Marks, Natalie; Shiferson, Alexander; Patel, Nirav; Gopal, Kapil; Jacob, Theresa
2009-09-01
Early limb occlusions following endovascular treatment of aorto-iliac aneurysmal disease is not uncommon (4%-13%). To assess whether the femoral artery entry site could potentially cause this complication, we prospectively evaluated the ipsilateral common femoral artery (CFA) and distal external iliac artery (EIA) with intraoperative duplex scans (IDS). There were 134 patients with infrarenal nonruptured abdominal aorto-iliac aneurysms treated with endografts since 2002 at our institution. Age ranged from 65 to 89 years (mean: 77 +/- 7 years). Aneuryx (n = 41), Zenith (n = 50), and Excluder (n = 43) endografts were used for repair. All procedures were performed via open exposure of the CFA. Introducer diameter varied from 12 mm to 22 mm. All patients underwent IDS of the CFA and distal EIA after repair of the arteriotomies. In 34 patients (25%), we documented intimal dissections causing severe (>70%) stenoses. Of the 271 arteries that were examined, 38 (14%) had abnormal findings that demanded intervention. These were repaired with flap excision, tacking sutures revision, or patch angioplasty (n = 36). Repeat IDS confirmed the adequacy of the repair. No statistical difference was noted if the site of larger introducer sheath and the incidence of flap formation. In addition, 10 small flaps or plaques were visualized but did not create significant stenosis. No differences were noted in the incidence of positive duplex exams between each type graft (P = .4). No early or late iliac limb occlusions were noted. Follow-up of 94% was obtained. Completion arterial duplex scans are helpful in detecting a substantial number of clinically unsuspected technical defects caused by introducer sheaths. Timely diagnosis and repair of these defects may decrease the incidence of early limb occlusion following endograft placement.
Wang, Dean; Jones, Kristofer J; Eliasberg, Claire D; Pais, Mollyann D; Rodeo, Scott A; Williams, Riley J
2017-10-04
Condyle-specific matching for osteochondral allograft transplantation (OCA) pairs donor and recipient condyles in an attempt to minimize articular incongruity. While the majority of cartilage defects are located on the medial femoral condyle, lateral femoral condyles are more commonly available as a graft source. The purpose of this study was to compare the clinical outcomes of patients treated with non-orthotopic (lateral-to-medial condyle or medial-to-lateral condyle) OCA with those treated with traditional orthotopic (medial-to-medial condyle or lateral-to-lateral condyle) OCA. We hypothesized that clinical outcomes would be similar between groups at midterm follow-up. A retrospective review of prospectively collected data on patients treated with OCA from 2000 to 2014 was conducted. Seventy-seven patients with a full-thickness cartilage defect of a femoral condyle were treated with either orthotopic (n = 50) or non-orthotopic (n = 27) OCA. A minimum follow-up of 2 years was required for analysis. Patients in each group were matched according to sex, age, and total chondral defect size. Reoperations and patient responses to validated outcome measures were reviewed. Failure was defined as any revision cartilage procedure or conversion to knee arthroplasty. The mean duration of follow-up was 4.0 years (range, 2 to 16 years). The orthotopic and non-orthotopic OCA groups were comparable in terms of demographics, the mean number of prior ipsilateral knee operations, and the percentage of concomitant procedures at baseline. Reoperation (p = 0.427) and failure (p = 0.917) rates did not differ significantly between groups. Both groups demonstrated significant increases in the Short Form-36 (SF-36) physical functioning and pain, International Knee Documentation Committee (IKDC), and Knee Outcome Survey-Activities of Daily Living (KOS-ADL) scores compared with baseline (p < 0.004). Outcome scores (baseline and postoperative) and change scores did not differ significantly between groups. Clinical outcomes do not differ between patients treated with orthotopic OCA and those treated with non-orthotopic OCA, suggesting that condyle-specific matching may not be necessary. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
CHOI, Sungjin; LIU, I-Li; YAMAMOTO, Kenichi; HONNAMI, Muneki; SAKAI, Takamasa; OHBA, Shinsuke; ECHIGO, Ryosuke; SUZUKI, Shigeki; NISHIMURA, Ryouhei; CHUNG, Ung-il; SASAKI, Nobuo; MOCHIZUKI, Manabu
2013-01-01
ABSTRACT We investigated biodegradability and new bone formation after implantation of tetrapod-shaped granular artificial bone (Tetrabone®) or β-tricalcium phosphate granules (β-TCP) in experimental critical-size defects in dogs, which were created through medial and lateral femoral condyles. The defect was packed with Tetrabone® (Tetrabone group) or β-TCP (β-TCP group) or received no implant (control group). Computed tomography (CT) was performed at 0, 4 and 8 weeks after implantation. Micro-CT and histological analysis were conducted to measure the non-osseous tissue rate and the area and distribution of new bone tissue in the defect at 8 weeks after implantation. On CT, β-TCP was gradually resorbed, while Tetrabone® showed minimal resorption at 8 weeks after implantation. On micro-CT, non-osseous tissue rate of the control group was significantly higher compared with the β-TCP and Tetrabone groups (P<0.01), and that of the β-TCP group was significantly higher compared with the Tetrabone group (P<0.05). On histology, area of new bone tissue of the β-TCP group was significantly greater than those of the Tetrabone and control groups (P<0.05), and new bone distribution of the Tetrabone group was significantly greater than those of the β-TCP and control groups (P<0.05). These results indicate differences in biodegradability and connectivity of intergranule pore structure between study samples. In conclusion, Tetrabone® may be superior for the repair of large bone defects in dogs. PMID:24161964
Choi, Sungjin; Liu, I-Li; Yamamoto, Kenichi; Honnami, Muneki; Sakai, Takamasa; Ohba, Shinsuke; Echigo, Ryosuke; Suzuki, Shigeki; Nishimura, Ryouhei; Chung, Ung-Il; Sasaki, Nobuo; Mochizuki, Manabu
2014-03-01
We investigated biodegradability and new bone formation after implantation of tetrapod-shaped granular artificial bone (Tetrabone®) or β-tricalcium phosphate granules (β-TCP) in experimental critical-size defects in dogs, which were created through medial and lateral femoral condyles. The defect was packed with Tetrabone® (Tetrabone group) or β-TCP (β-TCP group) or received no implant (control group). Computed tomography (CT) was performed at 0, 4 and 8 weeks after implantation. Micro-CT and histological analysis were conducted to measure the non-osseous tissue rate and the area and distribution of new bone tissue in the defect at 8 weeks after implantation. On CT, β-TCP was gradually resorbed, while Tetrabone® showed minimal resorption at 8 weeks after implantation. On micro-CT, non-osseous tissue rate of the control group was significantly higher compared with the β-TCP and Tetrabone groups (P<0.01), and that of the β-TCP group was significantly higher compared with the Tetrabone group (P<0.05). On histology, area of new bone tissue of the β-TCP group was significantly greater than those of the Tetrabone and control groups (P<0.05), and new bone distribution of the Tetrabone group was significantly greater than those of the β-TCP and control groups (P<0.05). These results indicate differences in biodegradability and connectivity of intergranule pore structure between study samples. In conclusion, Tetrabone® may be superior for the repair of large bone defects in dogs.
Modified femoral pressuriser generates a longer lasting high pressure during cement pressurisation
2011-01-01
Background The strength of the cement-bone interface in hip arthroplasty is strongly related to cement penetration into the bone. A modified femoral pressuriser has been investigated, designed for closer fitting into the femoral opening to generate higher and more constant cement pressure compared to a commercial (conventional) design. Methods Femoral cementation was performed in 10 Sawbones® models, five using the modified pressuriser and five using a current commercial pressuriser as a control. Pressure during the cementation was recorded at the proximal and distal regions of the femoral implant. The peak pressure and the pressure-time curves were analysed by student's t-test and Two way ANOVA. Results The modified pressuriser showed significantly and substantially longer durations at higher cementation pressures and slightly, although not statistically, higher peak pressures compared to the conventional pressuriser. The modified pressuriser also produced more controlled cement leakage. Conclusion The modified pressuriser generates longer higher pressure durations in the femoral model. This design modification may enhance cement penetration into cancellous bone and could improve femoral cementation. PMID:22004662
Further consideration of the curvature of the Neandertal Femur.
Chapman, Tara; Sholukha, Victor; Semal, Patrick; Louryan, Stéphane; Van Sint Jan, Serge
2018-01-01
Neandertal femora are particularly known for having a marked sagittal femoral curvature. This study examined femoral curvature in Neandertals in comparison to a modern human population from Belgium by the use of three-dimensional (3D) quadric surfaces modeled from the bone surface. 3D models provide detailed information and enabled femoral curvature to be analyzed in conjunction with other morphological parameters. 3D models were created from CT scans of 75 modern human femora and 7 Neandertal femora. Quadric surfaces (QS) were created from the triangulated surface vertices in all areas of interest (neck, head, diaphyseal shaft, condyles) extracted from previously placed anatomical landmarks. The diaphyseal shaft was divided into five QS shapes and curvature was measured by degrees of difference between QS shapes. Each bone was placed in a local coordinate system enabling each bone to be analyzed in the same way. The use of 3D quadric surface fitting allowed the distribution of curvature with similarly curved femora to be analyzed and the different patterns of curvature between the two groups to be determined. The Neandertals were shown to have a higher degree of femoral curvature and a more distal point of femoral curvature than the modern human population from Belgium. Morphological aspects of the Neandertal femur are different from this modern human population although mainly seem unrelated to femoral curvature. The relative lack of correlations with other femoral bony morphological factors suggests femoral curvature variations may be related to other aspects. © 2017 Wiley Periodicals, Inc.
Baksi, D D; Pal, A K; Baksi, D P
2016-01-01
Background: Ununited femoral neck fracture is seen commonly in developing countries due to delayed presentation or failure of primary internal fixation. Such fractures, commonly present with partial or total absorption of femoral neck, osteonecrosis of femoral head in 8–30% cases with upward migration of trochanter posing problem for osteosynthesis, especially in younger individuals. Several techniques for treatment of such conditions are described like osteotomies or nonvascularied cortical or cancellous bone grafting provided varying degrees of success in terms of fracture union but unsatisfactory long term results occurred due to varying incidence of avascular necrosis (AVN) of femoral head. Moreover, in presence of AVN of femoral head neither free fibular graft nor cancellous bone graft is satisfactory. The vascularied bone grafting by deep circumflex iliac artery based on iliac crest bone grafting, free vascularied fibular grafting and muscle pedicle periosteal grafting showed high incidence of success rate. Osteosynthesis is the preferred treatment of choice in ununited femoral neck fracture in younger individuals. Materials and Methods: Of the 293 patients operated during the period from June 1977 to June 2009, 42 were lost to followup. Seven patients with gluteus medius muscle pedicle bone grafting (MPBG) were excluded. Thus, out of 244 patients, 208 (85.3%) untreated nonunion and 36 (14.7%) following failure of primary internal fixation were available for studies. Time interval between the date of injury and operation in untreated nonunion cases was mean 6.5 months and in failed internal fixation cases was mean 11.2 months. Ages of the patients varied from 16 to 55 years. Seventy patients had partial and 174 had subtotal absorption of the femoral neck. Evidence of avascular necrosis (AVN) femoral head was found histologically in 135 (54.3%) and radiologically in 48 (19.7%) patients. The patients were operated by open reduction of fracture, cannulated hip screw fixation, iliac crest bone chips and quadratus femoris MPBG. Results: The mean followup is 12.5 years (range 3-35). The union of fractures occurred in 202 (82.8%), delayed union in 18 (7.3%), and established nonunion in 24 (9.8%) patients. Full weight bearing was permitted at 16–22 weeks after union of fractures. Mean Harris hip score at the longest followup was 85.5. Among the complications, superficial wound infection occurred in 20 (8.2%), deep infection in seven (2.9%), and coxa vara in 39 (16%) patients. Preoperative radiodensity of femoral head disappeared mostly after the union of fracture whereas fresh radiodensity of femoral head appeared in 20 (8%) patients; nine (45%) of them developed segmental collapse. Conclusion: Ununited femoral neck fractureis characterized by absorption of femoral neck, posterior cortical defect, smoothening and overriding of fracture surfaces with intervening fibrous tissues associated with or without AVN of femoral head. The above method of osteosynthesis rectified the above pathology and provided satisfactory results with union of fractures in 90.1% patients at long term followup. PMID:27512217
Kitamura, Shingo; Shirota, Minori; Fukuda, Wakako; Inamura, Takao; Fukuda, Ikuo
2016-12-01
Computational numerical analysis was performed to elucidate the flow dynamics of femoral artery perfusion. Numerical simulation of blood flow was performed from the right femoral artery in an aortic model. An incompressible Navier-Stokes equation and continuity equation were solved using computed flow dynamics software. Three different perfusion models were analyzed: a 4.0-mm cannula (outer diameter 15 French size), a 5.2-mm cannula (18 French size) and an 8-mm prosthetic graft. The cannula was inserted parallel to the femoral artery, while the graft was anastomosed perpendicular to the femoral artery. Shear stress was highest with the 4-mm cannula (172 Pa) followed by the graft (127 Pa) and the 5.2-mm cannula (99 Pa). The cannula exit velocity was high, even when the 5.2-mm cannula was used. Although side-armed perfusion with an 8-mm graft generated a high shear stress area near the point of anastomosis, flow velocity at the external iliac artery was decreased. The jet speed decreased due to the Coanda effect caused by the recirculation behind sudden expansion of diameter, and the flow velocity maintains a constant speed after the reattachment length of the flow. This study showed that iliac artery shear stress was lower with the 5.2-mm cannula than with the 4-mm cannula when used for femoral perfusion. Side-armed graft perfusion generates a high shear stress area around the anastomotic site, but flow velocity in the iliac artery is slower in the graft model than in the 5.2-mm cannula model.
Effects of Multiple Drilling on the Ischemic Capital Femoral Epiphysis of Immature Piglets
Gong, Sun Young; Kim, Hyun Woo; Park, Hui-Wan; Lee, Seung Yup
2011-01-01
Purpose This study investigated the effects of multiple drilling on the immature capital femoral epiphysis following ischemic injury in a piglet model. Materials and Methods Ischemic necrosis of capital femoral epiphysis was induced bilaterally in 12 piglets using a cervical ligation method. Three weeks later, medial, central, and lateral 3 drill holes were made on the left femoral head using 0.062" K-wire. At 3, 6, 9, and 12 weeks following the multiple drilling, femoral heads were harvested from each three piglets. On histologic examination, percent of revascularization, percent of osteoblast surface, capital femoral epiphyseal quotient and proximal femoral growth plate height were evaluated. Untreated right femoral heads served as control. Results While percent of revascularization of left capital femoral epiphysis with multiple drilling was significantly higher than untreated control side (p<0.001), percent of osteoblast surface, capital femoral epiphyseal quotient and proximal femoral growth plate height showed no significant difference. Conclusion This study indicates that multiple drilling could promote revascularization of ischemic capital femoral epiphysis, and multiple drilling does not appear to produce bony physeal bars at short-term, if using small diameter drill. However, multiple drilling alone does not seem to prevent femoral head deformity or to promote new bone formation. PMID:21786447
Kim, Sung-Jae; Chun, Yong-Min; Kim, Sung-Hwan; Moon, Hong-Kyo; Jang, Jae-Won
2013-07-01
The purpose of this study was to compare four graft-tunnel angles (GTA), the femoral GTA formed by three different femoral tunneling techniques (the outside-in, a modified inside-out technique in the posterior sag position with knee hyperflexion, and the conventional inside-out technique) and the tibia GTA in 3-dimensional (3D) knee flexion models, as well as to examine the influence of femoral tunneling techniques on the contact pressure between the intra-articular aperture of the femoral tunnel and the graft. Twelve cadaveric knees were tested. Computed tomography scans were performed at different knee flexion angles (0°, 45°, 90°, and 120°). Femoral and tibial GTAs were measured at different knee flexion angles on the 3D knee models. Using pressure sensitive films, stress on the graft of the angulation of the femoral tunnel aperture was measured in posterior cruciate ligament reconstructed cadaveric knees. Between 45° and 120° of knee flexion, there were no significant differences between the outside-in and modified inside-out techniques. However, the femoral GTA for the conventional inside-out technique was significantly less than that for the other two techniques (p<0.001). In cadaveric experiments using pressure-sensitive film, the maximum contact pressure for the modified inside-out and outside-in technique was significantly lower than that for the conventional inside-out technique (p=0.024 and p=0.017). The conventional inside-out technique results in a significantly lesser GTA and higher stress at the intra-articular aperture of the femoral tunnel than the outside-in technique. However, the results for the modified inside-out technique are similar to those for the outside-in technique.
Mao, Yujiang; Song, Jie; Wei, Jie; Wang, Manyi
2010-01-01
Unrecognized joint penetration (UJP) by screw penetration through the articular surface undetectable on routine anteroposterior (AP) and lateral radiographs can cause serious complications. We have developed a geometric model to analyze UJP, and methods for the prevention of the problem. A Steinmetz Solid (SS) is the overlapping portion between two identical, vertically intersecting cylinders. The AP and lateral radiographs of a femoral head (simplified as a sphere) are projections of two cylinder-shaped images. A screw that appears to be within the femoral head in fact only lies within the cylinder. A screw apparently within the femoral head on both AP and lateral images is only confined to the SS generated by two cylinders, but not necessarily confined to the femoral head itself. We have therefore analyzed UJP using a geometric model based on SS. The geometric basis of UJP lies in the fact that the SS is larger than the sphere (femoral head) with a volume ratio of 4: π. The theoretical risk of UJP for any screw therefore can be as high as 21.5% ((4-π)/4). In reality, screws are always carefully placed to ensure a distance between the screw's tip and the edge of femoral head (tip-to-edge distance, or TED). This TED effectively lowers the risk of UJP by reducing the size of the screw-confining SS. When the SS entirely fits into (internally tangential to) the femoral head, the risk of UJP approaches zero. A TED fulfilling this requirement can be regarded as safe (approximately 0.29 x femoral head radius). With a femoral head diameter of 5 cm, the safe TED is approximately 7 mm.
Effects of osteochondral defect size on cartilage regeneration using a double-network hydrogel.
Higa, Kotaro; Kitamura, Nobuto; Goto, Keiko; Kurokawa, Takayuki; Gong, Jian Ping; Kanaya, Fuminori; Yasuda, Kazunori
2017-05-22
There has been increased interest in one-step cell-free procedures to avoid the problems related to cell manipulation and its inherent disadvantages. We have studied the chondrogenic induction ability of a PAMPS/PDMAAm double-network (DN) gel and found it to induce chondrogenesis in animal osteochondral defect models. The purpose of this study was to investigate whether the healing process and the degree of cartilage regeneration induced by the cell-free method using DN gel are influenced by the size of osteochondral defects. A total of 63 mature female Japanese white rabbits were used in this study, randomly divided into 3 groups of 21 rabbits each. A 2.5-mm diameter osteochondral defect was created in the femoral trochlea of the patellofemoral joint of bilateral knees in Group I, a 4.3-mm osteochondral defect in Group II, and a 5.8-mm osteochondral defect in Group III. In the right knee of each animal, a DN gel plug was implanted so that a vacant space of 2-mm depth was left above the plug. In the left knee, we did not conduct any treatment to obtain control data. Animals were sacrificed at 2, 4, and 12 weeks after surgery, and gross and histological evaluations were made. The present study demonstrated that all sizes of the DN gel implanted defects as well as the 2.5mm untreated defects showed cartilage regeneration at 4 and 12 weeks. The 4.3-mm and 5.8-mm untreated defects did not show cartilage regeneration during the 12-week period. The quantitative score reported by O'Driscoll et al. was significantly higher in the 4.3-mm and 5.8-mm DN gel-implanted defects than the untreated defects at 4 and 12 weeks (p < 0.05). The 2.5-mm and 4.3-mm DN gel implanted defects maintained relatively high macroscopic and histological scores for the 12-week implantation period, while the histological score of the 5.8-mm DN gel implanted defect had decreased somewhat but statistically significantly at 12 weeks (p = 0.0057). The DN gel induced cartilage regeneration in defects between 2.5 and 5.8 mm, offering a promising device to establish a cell-free cartilage regeneration therapy and applicable to various sizes of osteochondral defects.
Evaluation of a press-fit osteochondral poly(ester-urethane) scaffold in a rabbit defect model.
Dresing, Iska; Zeiter, Stephan; Auer, Jörg; Alini, Mauro; Eglin, David
2014-07-01
The purpose of this study was to evaluate the impact on osteochondral healing of press-fitted multiphasic osteochondral scaffolds consisting of poly(ester-urethane) (PUR) and hydroxyapatite into a cylindric osteochondral defect in the distal non-weight bearing femoral trochlear ridge of the rabbit. Two scaffolds were investigated, one with and one without an intermediate microporous membrane between the cartilage and the bone compartment of the scaffold. A control group without a scaffold placed into the defect was included. After 12 weeks macroscopic and histomorphological analyses were performed. The scaffold was easily press-fitted and provided a stable matrix for tissue repair. The membrane did not demonstrate a detrimental effect on tissue healing compared with the scaffold without membrane. However, the control group had statistically superior healing as reflected by histological differences in the cartilage and subchondral bone compartment between control group and each scaffold group. A more detailed analysis revealed that the difference was localized in the bone compartment healing. The present study demonstrates that an elastomeric PUR scaffold can easily be press-fitted into an osteochondral defect and provides a stable matrix for tissue repair. However, the multi-phasic scaffold did not provide a clear advantage for tissue healing. Future investigations should refine especially the bone phase of the implant to increase its stiffness, biocompatibility and osteoconductive activity. A more precise fabrication technique would be necessary for the matching of tissue organisation.
Knothe Tate, Melissa L; Dolejs, Scott; McBride, Sarah H; Matthew Miller, R; Knothe, Ulf R
2011-08-01
The link between mechanics and biology in the generation and the adaptation of bone has been studied for more than a century in the context of skeletal development and fracture healing. However, the interplay between mechanics and biology in de novo generation of bone in postnatal defects as well as healing of morcellized bone graft or massive cortical bone autografts is less well understood. To address this, here we integrate insights from our previously published studies describing the mechanobiology on both de novo bone generation and graft healing in a common ovine femoral defect model. Studying these effects in a common experimental model provides a unique opportunity to elucidate factors conducive to harnessing the regenerative power of the periosteum, and ultimately, to provide mechanistic insights into the multiscale mechanobiology of bone generation, remodeling and adaptation. Taken together, the studies indicate that, as long as adequate, directional transport of cells and molecules can be insured (e.g. with periosteum in situ or a delivery device), biological factors intrinsic to the periosteum suffice to bridge critical sized bone defects, even in the absence of a patent blood supply. Furthermore, mechanical stimuli are crucial for the success of periosteal bone generation and bone graft healing. Interestingly, areas of highest periosteal strain around defects correlate with greatest amounts albeit not greatest mineralization of newly generated bone. This may indicate a role for convection enhanced transport of cells and molecules in modulation of tissue generation by pluripotent cells that ingress into the defect center, away from the periosteum and toward the surface of the intramedullary nail that fills the medullary cavity. These insights bring us much closer to understanding the mechanobiological environment and stimuli that stimulate the proliferation and differentiation of periosteum-derived progenitor cells and ultimately drive the generation of new bone tissue. Furthermore, these insights provide a foundation to create virtual predictive computational models of bone mechanophysiology, to develop cell seeding protocols for scale up and manufacture of engineered tissues, to optimize surgical procedures, and to develop post-surgical therapies with the ultimate goal of achieving the best possible healing outcomes for treatment and/or reconstruction of postnatal bone defects. Copyright © 2011 Elsevier Ltd. All rights reserved.
Hu, Zhi-ming; Zhou, Ming-qian; Gao, Ji-min
2008-12-01
To evaluate the therapeutic effect of vascular endothelial growth factor (VEGF) and tumor necrosis factor receptor (TNFR) on avascular necrosis of the femoral head in rabbits. Avascular necrosis of the femoral head was induced in 26 New Zealand white rabbits by injections of horse serum and prednisolone. The rabbits were then divided into VEGF/TNFR treatment group, VEGF treatment group, and untreated model group, with another 4 normal rabbits as the normal control group. In the two treatment groups, the therapeutic agents were injected percutaneously into the femoral head. Enzyme-linked immunosorbent assay was performed to determine the concentration of TNF-alpha in rabbit serum followed by pathological examination of the changes in the bone tissues, bone marrow hematopoietic tissue and the blood vessels in the femoral head. Compared with the model group, the rabbits with both VEGF and TNFR treatment showed decreased serum concentration of TNF-alpha with obvious new vessel formation, decreased empty bone lacunae in the femoral head and hematopoietic tissue proliferation in the bone marrow cavity. Percutaneous injection of VEGF and TNFR into the femoral head can significantly enhance bone tissue angiogenesis and ameliorate osteonecrosis in rabbits with experimental femoral head necrosis.
New options for vascularized bone reconstruction in the upper extremity.
Houdek, Matthew T; Wagner, Eric R; Wyles, Cody C; Nanos, George P; Moran, Steven L
2015-02-01
Originally described in the 1970s, vascularized bone grafting has become a critical component in the treatment of bony defects and non-unions. Although well established in the lower extremity, recent years have seen many novel techniques described to treat a variety of challenging upper extremity pathologies. Here the authors review the use of different techniques of vascularized bone grafts for the upper extremity bone pathologies. The vascularized fibula remains the gold standard for the treatment of large bone defects of the humerus and forearm, while also playing a role in carpal reconstruction; however, two other important options for larger defects include the vascularized scapula graft and the Capanna technique. Smaller upper extremity bone defects and non-unions can be treated with the medial femoral condyle (MFC) free flap or a vascularized rib transfer. In carpal non-unions, both pedicled distal radius flaps and free MFC flaps are viable options. Finally, in skeletally immature patients, vascularized fibular head epiphyseal transfer can provide growth potential in addition to skeletal reconstruction.
Bota, Olimpiu; Spindler, Nick; Sauber, Jeannine; Aydogan, Emrah; Langer, Stefan
2017-08-01
Soft-tissue defects caused by radiation injury are a challenging task for the reconstructive surgeon, due to the extent of the soft-tissue damage and the associated injuries of the local blood vessels and bone tissue. We present the application of the versatile deep inferior epigastric perforator (DIEP) flap for the coverage of an extended lateral thigh soft-tissue defect after the surgical resection of an undifferentiated pleomorphic high-grade sarcoma, neoadjuvant chemotherapy, and adjuvant chemo- and radiotherapy. A double-pedicled free DIEP flap (756 cm 2 ) was harvested and anastomosed to the transverse branch of the lateral femoral circumflex artery and a lateral branch of the popliteal artery (P1). The flap survived completely without serious complications, and the patient was able to walk with crutches 3 months postoperatively. This is the first case report of a free bipedicled DIEP flap for the coverage of a thigh defect in a male patient.
Spindler, Nick; Sauber, Jeannine; Aydogan, Emrah; Langer, Stefan
2017-01-01
Summary: Soft-tissue defects caused by radiation injury are a challenging task for the reconstructive surgeon, due to the extent of the soft-tissue damage and the associated injuries of the local blood vessels and bone tissue. We present the application of the versatile deep inferior epigastric perforator (DIEP) flap for the coverage of an extended lateral thigh soft-tissue defect after the surgical resection of an undifferentiated pleomorphic high-grade sarcoma, neoadjuvant chemotherapy, and adjuvant chemo- and radiotherapy. A double-pedicled free DIEP flap (756 cm2) was harvested and anastomosed to the transverse branch of the lateral femoral circumflex artery and a lateral branch of the popliteal artery (P1). The flap survived completely without serious complications, and the patient was able to walk with crutches 3 months postoperatively. This is the first case report of a free bipedicled DIEP flap for the coverage of a thigh defect in a male patient. PMID:28894652
Gok, Kadir; Inal, Sermet; Gok, Arif; Gulbandilar, Eyyup
2017-05-01
In this study, biomechanical behaviors of three different screw materials (stainless steel, titanium and cobalt-chromium) have analyzed to fix with triangle fixation under axial loading in femoral neck fracture and which material is best has been investigated. Point cloud obtained after scanning the human femoral model with the three dimensional (3D) scanner and this point cloud has been converted to 3D femoral model by Geomagic Studio software. Femoral neck fracture was modeled by SolidWorks software for only triangle configuration and computer-aided numerical analyses of three different materials have been carried out by AnsysWorkbench finite element analysis (FEA) software. The loading, boundary conditions and material properties have prepared for FEA and Von-Misses stress values on upper and lower proximity of the femur and screws have been calculated. At the end of numerical analyses, the best advantageous screw material has calculated as titanium because it creates minimum stress at the upper and lower proximity of the fracture line.
Fixation free femoral hernia repair with a 3D dynamic responsive implant. A case series report.
Amato, G; Romano, G; Agrusa, A; Gordini, L; Gulotta, E; Erdas, E; Calò, P G
2018-04-23
To date, no gold standard for the surgical treatment of femoral hernia exists. Pure tissue repair as well as mesh/plug implantation, open or laparoscopic, are the most performed methods. Nevertheless, all these techniques need sutures or mesh fixation. This implies the risk of damaging sensitive structures of the femoral area, along with complications related to tissue tear and postoperative discomfort consequent to poor quality mesh incorporation. The present retrospective multicenter case series highlights the results of femoral hernia repair procedures performed with a 3D dynamic responsive implant in a cohort of 32 patients during a mean follow up of 27 months. Aiming to simplify the surgical procedure and reduce complications, a 3D dynamic responsive implant was delivered for femoral hernia repair, in a patient cohort. After returning the hernia sack to the abdominal cavity, the implant was simply delivered into the hernia defect where it remained, thanks to its inherent centrifugal expansion, obliterating the hernia opening without need of fixation. Postoperative pain assessment was determined using the VAS score system. The use of the 3D prosthetic device allowed for easier and faster surgical repair in a fixation free fashion. None of the typical fixation related complications occurred in the examined patients. Postoperative pain assessment with VAS score showed a very low level of pain, allowing the return of patients to normal activities in extremely reduced times. In the late postoperative period, no discomfort or chronic pain was reported. Femoral hernia repair with the 3D dynamic revealed a quick and safe placement procedure. The reduced pain intensity, as well as the absence of adverse events consequent to sutures or mesh fixation, seems to be a significant benefit of the motile compliance of the device. Furthermore, this 3D prosthesis has already proven to induce an enhanced probiotic response showing ingrowth in the implant of the typical tissue components of the abdominal wall, instead of the low quality tissue ingrowth typical in conventional meshes and plugs. The highlighted features seem to represent a more physiologic and updated repair concept of femoral protrusions. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Self-fitting shape memory polymer foam inducing bone regeneration: A rabbit femoral defect study.
Xie, Ruiqi; Hu, Jinlian; Hoffmann, Oskar; Zhang, Yuanchi; Ng, Frankie; Qin, Tingwu; Guo, Xia
2018-04-01
Although tissue engineering has been attracted greatly for healing of critical-sized bone defects, great efforts for improvement are still being made in scaffold design. In particular, bone regeneration would be enhanced if a scaffold precisely matches the contour of bone defects, especially if it could be implanted into the human body conveniently and safely. In this study, polyurethane/hydroxyapatite-based shape memory polymer (SMP) foam was fabricated as a scaffold substrate to facilitate bone regeneration. The minimally invasive delivery and the self-fitting behavior of the SMP foam were systematically evaluated to demonstrate its feasibility in the treatment of bone defects in vivo. Results showed that the SMP foam could be conveniently implanted into bone defects with a compact shape. Subsequently, it self-matched the boundary of bone defects upon shape-recovery activation in vivo. Micro-computed tomography determined that bone ingrowth initiated at the periphery of the SMP foam with a constant decrease towards the inside. Successful vascularization and bone remodeling were also demonstrated by histological analysis. Thus, our results indicate that the SMP foam demonstrated great potential for bone regeneration. Copyright © 2018 Elsevier B.V. All rights reserved.
Komatsu, Jun; Nagura, Nana; Iwase, Hideaki; Igarashi, Mamoru; Ohbayashi, Osamu; Nagaoka, Isao; Kaneko, Kazuo
2018-01-01
Grafting β-tricalcium phosphate (TCP) is a well-established method for restoring bone defects; however, there is concern that the mechanical stability of the grafted β-TCP is not maintained during bone translation. Teriparatide has an anabolic effect, stimulating bone formation and increasing bone mineral density for the treatment of osteoporosis. The aim of the present study was to evaluate the effect of intermittent teriparatide treatment on changes in bone grafted with β-TCP using a rabbit bone defect model. Bone defects (5×15 mm) were created in the distal femoral condyle of Japanese white rabbits, and β-TCP granules of two different total porosities were manually grafted. Teriparatide (40 µg/kg) or 0.2% rabbit serum albumin solution as a vehicle control was subcutaneously injected three times per week following the surgery. At 4 or 8 weeks post-surgery, serum samples were obtained and the levels of γ-carboxylated osteocalcin (Gla-OC) were quantified using ELISA. Histomorphometry was also performed using sections of graft sites following staining for tartrate resistant acid phosphatase. Activity and mechanical strength (maximum shear strength, maximum shear stiffness and total energy absorption) were evaluated using an axial push-out load to failure test. Teriparatide treatment significantly increased (P<0.05) the serum levels of Gla-OC, a specific marker for bone formation, suggesting that teriparatide enhances bone formation in β-TCP-grafted rabbits. Furthermore teriparatide increased the degradation of β-TCP by bone remodeling (P<0.05) and promoted the formation of new bone following application of the graft compared with the control group (P<0.01). Furthermore, teriparatide suppressed the reduction in mechanical strength (P<0.05) during bone translation in bone defects grafted with β-TCP. The results of the present study demonstrate that teriparatide is effective in maintaining the mechanical stability of grafted β-TCP, possibly by promoting new bone formation. PMID:29387179
Osteochondral graft from the pre-achilles area for replacement of articular surface defects
NASA Astrophysics Data System (ADS)
Kuznetsov, V. V.; Pahomov, I. A.; Prohorenko, V. M.; Sadovoy, M. A.; Korel, A. V.; Zaydman, A. M.; Repin, A. V.; Gudi, S. M.; Korochkin, S. B.
2017-09-01
We substantiate a new technique for obtaining osteochondral autograft to replace osteochondral defects resulting from various lesions of the talar trochlea by means of morphological examination of the following microslides: talar cartilage (cadaver material), cartilage portion of the pre-achilles zone of the calcaneum, lateral femoral condyle, and necrotic area of the talus. Examination of the specimens of the pre-achilles cartilage of the calcaneus revealed a large number of poorly differentiated chondroblasts in the homogeneously stained extracellular matrix; the presence of all zones (superficial zone, zone of columnar structures, and "tidemark"). This is indicative of structural and functional preservation of this cartilage, which therefore can be considered as an autograft material.
Pediatric femoral hernia in the laparoscopic era.
Aneiros Castro, Belén; Cano Novillo, Indalecio; García Vázquez, Araceli; López Díaz, María; Benavent Gordo, María Isabel; Gómez Fraile, Andrés
2017-12-20
Femoral hernia is a rare and often misdiagnosed condition in childhood. The aim of our study was to demonstrate that the laparoscopic approach improves diagnostic accuracy and offers a safe and effective treatment. A retrospective study of 687 pediatric patients who underwent laparoscopic inguinal hernia repair from January 2000 to December 2015 was performed. Femoral hernias were identified in 16 patients (2.3%). The right side was affected in 10 cases (62.5%), the left side in 5 (31.2%), and 1 case was bilateral (6.2%). The mean age of patients was 8.00 ± 3.81 years, and there was a male predominance. Preoperative diagnosis was femoral hernia in eight cases (50%) and indirect inguinal hernia in the remaining eight (50%). Seven children (43.8%) presented with hernia recurrence after having undergone an open ipsilateral indirect hernia repair. A modified laparoscopic McVay technique was performed in 12 cases (70.6%). An epigastric artery injury by trocar occurred in one patient. All operations were completed laparoscopically. The mean surgical time was 45.6 ± 22.9 min for unilateral cases and 110 ± 10.0 min for bilateral cases. No immediate postoperative complications were noted. The mean postoperative hospital stay was 0.6 ± 0.4 days. No recurrence was observed after a median follow-up of 11 years (range, 4-16 years). Femoral hernia is a rare pathology in pediatric patients that is often difficult to diagnose. The laparoscopic approach is effective in the diagnosing and treating these hernias, and it allows for the simultaneous repair of multiple groin defects. © 2017 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.
Sasaki, T; Akagi, R; Akatsu, Y; Fukawa, T; Hoshi, H; Yamamoto, Y; Enomoto, T; Sato, Y; Nakagawa, R; Takahashi, K; Yamaguchi, S; Sasho, T
2017-03-01
The aim of this study was to investigate the effect of granulocyte-colony stimulating factor (G-CSF) on mesenchymal stem cell (MSC) proliferation in vitro and to determine whether pre-microfracture systemic administration of G-CSF (a bone marrow stimulant) could improve the quality of repaired tissue of a full-thickness cartilage defect in a rabbit model. MSCs from rabbits were cultured in a control medium and medium with G-CSF (low-dose: 4 μg, high-dose: 40 μg). At one, three, and five days after culturing, cells were counted. Differential potential of cultured cells were examined by stimulating them with a osteogenic, adipogenic and chondrogenic medium.A total of 30 rabbits were divided into three groups. The low-dose group (n = 10) received 10 μg/kg of G-CSF daily, the high-dose group (n = 10) received 50 μg/kg daily by subcutaneous injection for three days prior to creating cartilage defects. The control group (n = 10) was administered saline for three days. At 48 hours after the first injection, a 5.2 mm diameter cylindrical osteochondral defect was created in the femoral trochlea. At four and 12 weeks post-operatively, repaired tissue was evaluated macroscopically and microscopically. The cell count in the low-dose G-CSF medium was significantly higher than that in the control medium. The differentiation potential of MSCs was preserved after culturing them with G-CSF.Macroscopically, defects were filled and surfaces were smoother in the G-CSF groups than in the control group at four weeks. At 12 weeks, the quality of repaired cartilage improved further, and defects were almost completely filled in all groups. Microscopically, at four weeks, defects were partially filled with hyaline-like cartilage in the G-CSF groups. At 12 weeks, defects were repaired with hyaline-like cartilage in all groups. G-CSF promoted proliferation of MSCs in vitro . The systemic administration of G-CSF promoted the repair of damaged cartilage possibly through increasing the number of MSCs in a rabbit model. Cite this article : T. Sasaki, R. Akagi, Y. Akatsu, T. Fukawa, H. Hoshi, Y. Yamamoto, T. Enomoto, Y. Sato, R. Nakagawa, K. Takahashi, S. Yamaguchi, T. Sasho. The effect of systemic administration of G-CSF on a full-thickness cartilage defect in a rabbit model MSC proliferation as presumed mechanism: G-CSF for cartilage repair. Bone Joint Res 2017;6:123-131. DOI: 10.1302/2046-3758.63.BJR-2016-0083. © 2017 Sasho et al.
Hydroxyapatite clay for gap filling and adequate bone ingrowth.
Maruyama, M; Terayama, K; Ito, M; Takei, T; Kitagawa, E
1995-03-01
In uncemented total hip arthroplasty, a complete filling of the gap between femoral prosthesis and the host bone is difficult and defects would remain, because the anatomy of the reamed intramedullary canal cannot fit the prosthesis. Therefore, it seems practical to fill the gap with a clay containing hydroxyapatite (HA), which has an osteoconductive character. The clay (HA clay) is made by mixing HA granules (size 0.1 mm or more) having a homogeneous pore distribution and a porosity of 35-48 vol%, and a viscous substance such as a saline solution of sodium alginate (SSSA). In the first experiment, the ratio of HA granules and sodium alginate in SSSA is set for the same handling properties of HA clay and polymethylmethacrylate bone cement (standard viscosity) before hardening. As a result, the ratio is set for 55 wt% of HA in the clay and 12.5 wt% of sodium alginate in SSSA (i.e., HA:sodium alginate:saline solution = 9.8:1:7). In the second study, the gap between the femoral stem and bone model is completely filled with HA clay. However, the gap is not filled only with HA granules or HA granules mixed with saline solution. In the third animal experiment, using an unloaded model, histology shows that HA clay has an osteoconductive property bridging the gap between the implant and the cortical bone without any adverse reaction. HA clay is considered a useful biomaterial to fill the gap with adequate bone ingrowth.
Baier, Martin; Staudt, Patric; Klein, Roman; Sommer, Ulrike; Wenz, Robert; Grafe, Ingo; Meeder, Peter Jürgen; Nawroth, Peter P; Kasperk, Christian
2013-06-07
Calcium phosphate cements are used frequently in orthopedic and dental surgeries. Strontium-containing drugs serve as systemic osteoblast-activating medication in various clinical settings promoting mechanical stability of the osteoporotic bone. Strontium-containing calcium phosphate cement (SPC) and calcium phosphate cement (CPC) were compared regarding their local and systemic effects on bone tissue in a standard animal model for osteoporotic bone. A bone defect was created in the distal femoral metaphysis of 60 ovariectomized Sprague-Dawley rats. CPC and SPC were used to fill the defects in 30 rats in each group. Local effects were assessed by histomorphometry at the implant site. Systemic effects were assessed by bone mineral density (BMD) measurements at the contralateral femur and the spine. Faster osseointegration and more new bone formation were found for SPC as compared to CPC implant sites. SPC implants exhibited more cracks than CPC implants, allowing more bone formation within the implant. Contralateral femur BMD and spine BMD did not differ significantly between the groups. The addition of strontium to calcium phosphate stimulates bone formation in and around the implant. Systemic release of strontium from the SPC implants did not lead to sufficiently high serum strontium levels to induce significant systemic effects on bone mass in this rat model.
Mallik, Prafulla Kumar; Basu, Bikramjit
2014-03-01
In view of the fact that bone healing can be enhanced due to external electric field application, it is important to assess the influence of the implant conductivity on the bone regeneration in vivo. To address this issue, this study reports the in vivo biocompatibility property of multistage spark plasma sintered hydroxyapatite (HA)-80 wt % calcium titanate (CaTiO3 ) composites and monolithic HA, which have widely different conductivity property (14 orders of magnitude difference). The ability of bone regeneration was assessed by implantation in cylindrical femoral bone defects of rabbit animal model for varying time period of 1, 4, and 12 weeks. The overall assessment of the histology results suggests that the progressive healing of bone defects around HA-80 wt % CaTiO3 is associated with a better efficacy with respect to (w.r.t) early stage neobone formation, which is histomorphometrically around 140% higher than monolithic HA. Overall, this study demonstrates that the in vivo biocompatibility property of HA-80 wt % CaTiO3 with respect to local effects after 12 weeks of implantation is not compromised both qualitatively and quantitatively, and a comparison with control implant (HA) points toward the critical role of electrical conductivity on better early stage bone regeneration. Copyright © 2013 Wiley Periodicals, Inc.
Biodegradable implants for Pipkin fractures.
Prokop, Axel; Helling, Hanns-Joachim; Hahn, Ulrich; Udomkaewkanjana, Chira; Rehm, Klaus Emil
2005-03-01
The current study was designed to clarify whether biodegradable poly-L/DL lactide pins provide an operative alternative for fixation of Pipkin fractures. Nine patients with Pipkin fractures (one with Pipkin Type I, one with Pipkin Type II, and seven with Pipkin Type IV fractures) were treated surgically between 1996 and 2002. In all patients, the femoral head fractures were fixed with biodegradable, 2.7-mm and 2.0-mm polylactide pins. Eight patients were followed up for an average of 54.2 months. One patient died before the final followup. Eight fractures healed uneventfully. In one patient, a persisting femoral head defect led to posttraumatic arthritis requiring insertion of a femoral endoprosthesis at 1 year. The average range of motion of the affected hips of all patients at followup was 109 degrees -0 degrees -0 degrees in flexion and extension. External and internal rotation averaged 37 degrees -0 degrees -29 degrees . One patient had Brooker Grade I heterotopic ossification develop, and another had a Grade II heterotopic develop. Merle d'Aubigne and Postel ratings showed two excellent and five satisfactory results (average score, 13.1). Adverse effects from the polylactide implants were not observed. Pipkin fractures can be fixed successfully with biodegradable polylactide pins.
Guzzini, Matteo; Guidi, Marco; Civitenga, Carolina; Ferri, Germano; Ferretti, Andrea
2016-01-01
Introduction. The vascularized corticoperiosteal flap is harvested from the medial femoral condyle and it is nourished by the articular branch of the descending genicular artery and the superomedial genicular artery. This flap is usually harvested as a free flap for the reconstruction of bone defects at forearm, distal radius, carpus, hand, and recently at lower limb too. Case Report. A 50-year-old Caucasian man referred to our department for hypertrophic nonunion of the distal femur, refractory to the conservative treatments. The first surgical choice was the revision of the nail and the bone reconstruction with a corticoperiosteal pedicled flap from the medial femoral condyle. We considered union to have occurred 3.5 months after surgery when radiographs showed bridging of at least three of the four bony cortices and clinically the patient was able to walk with full weight bearing without any pain. At the last follow-up (25 months), the patient was completely satisfied with the procedure. Discussion. The corticoperiosteal flap allows a faster healing of fractures with a minimal morbidity at the donor site. We suggest that the corticoperiosteal pedicled flap graft is a reliable and effective treatment for distal femur nonunion. PMID:27064589
The influence of patient factors on femoral rotation after total hip arthroplasty.
Tezuka, Taro; Inaba, Yutaka; Kobayashi, Naomi; Choe, Hyonmin; Higashihira, Syota; Saito, Tomoyuki
2018-06-09
A postoperative change in femoral rotation following total hip arthroplasty (THA) might be the cause of dislocation due to the change in combined anteversion. However, very few studies have evaluated the femoral rotation angle following THA, or the factors that influence femoral rotation. We aimed to evaluate changes in femoral rotation after THA, and to investigate preoperative patient factors that influence femoral rotation after THA. This study involved 211 hips treated with primary THA. We used computed tomography to measure the femoral rotation angle before and one week after THA. In addition, multiple regression analysis was performed to evaluate preoperative patient factors that could influence femoral rotation after THA. The femoral rotation angle was 0.2 ± 14° externally before surgery and 4.4 ± 12° internally after surgery (p < 0.001). Multiple regression analysis revealed that sex (β = 0.19; p = 0.003), age (β = 0.15; p = 0.017), preoperative anatomical femoral anteversion (β = - 0.25; p = 0.002), and preoperative femoral rotation angle (β = 0.36; p < 0.001) were significantly associated with the postoperative femoral rotation angle. The final model of the regression formula was described by the following equation: [postoperative femoral rotation angle = 5.41 × sex (female: 0, male: 1) + 0.15 × age - 0.22 × preoperative anatomical femoral anteversion + 0.33 × preoperative femoral rotation angle - 10.1]. The current study showed the mean internal change of 4.6° in the femoral rotation angle one week after THA. Sex, age, preoperative anatomical femoral anteversion and preoperative femoral rotation were associated with postoperative femoral rotation. The patients who were male, older, and who exhibited lesser preoperative anatomical femoral anteversion or greater preoperative femoral rotation angles, tended to demonstrate an externally rotated femur after THA. Conversely, patients who were female, younger, and who exhibited greater preoperative anatomical femoral anteversion or lesser preoperative femoral rotation angles, tended to demonstrate an internal rotation of the femur after THA.
Nagel, Thomas; Kelly, Daniel J
2010-06-01
A number of mechano-regulation theories have been proposed that relate the differentiation pathway of mesenchymal stem cells (MSCs) to their local biomechanical environment. During spontaneous repair processes in skeletal tissues, the organisation of the extracellular matrix is a key determinant of its mechanical fitness. In this paper, we extend the mechano-regulation theory proposed by Prendergast et al. (J Biomech 30(6):539-548, 1997) to include the role of the mechanical environment on the collagen architecture in regenerating soft tissues. A large strain anisotropic poroelastic material model is used in a simulation of tissue differentiation in a fracture subject to cyclic bending (Cullinane et al. in J Orthop Res 20(3):579-586, 2002). The model predicts non-union with cartilage and fibrous tissue formation in the defect. Predicted collagen fibre angles, as determined by the principal decomposition of strain- and stress-type tensors, are similar to the architecture seen in native articular cartilage and neoarthroses induced by bending of mid-femoral defects in rats. Both stress and strain-based remodelling stimuli successfully predicted the general patterns of collagen fibre organisation observed in vivo. This provides further evidence that collagen organisation during tissue differentiation is determined by the mechanical environment. It is envisioned that such predictive models can play a key role in optimising MSC-based skeletal repair therapies where recapitulation of the normal tissue architecture is critical to successful repair.
Bone regeneration capacity of magnesium phosphate cements in a large animal model.
Kanter, Britta; Vikman, Anna; Brückner, Theresa; Schamel, Martha; Gbureck, Uwe; Ignatius, Anita
2018-03-15
Magnesium phosphate minerals have captured increasing attention during the past years as suitable alternatives for calcium phosphate bone replacement materials. Here, we investigated the degradation and bone regeneration capacity of experimental struvite (MgNH 4 PO 4 ·6H 2 O) forming magnesium phosphate cements in two different orthotopic ovine implantation models. Cements formed at powder to liquid ratios (PLR) of 2.0 and 3.0 g ml -1 were implanted into trabecular bone using a non-load-bearing femoral drill-hole model and a load-bearing tibial defect model. After 4, 7 and 10 months the implants were retrieved and cement degradation and new bone formation was analyzed by micro-computed tomography (µCT) and histomorphometry. The results showed cement degradation in concert with new bone formation at both defect locations. Both cements were almost completely degraded after 10 months. The struvite cement formed with a PLR of 2.0 g ml -1 exhibited a slightly accelerated degradation kinetics compared to the cement with a PLR of 3.0 g ml -1 . Tartrat-resistant acid phosphatase (TRAP) staining indicated osteoclastic resorption at the cement surface. Energy dispersive X-ray analysis (EDX) revealed that small residual cement particles were mostly accumulated in the bone marrow in between newly formed bone trabeculae. Mechanical loading did not significantly increase bone formation associated with cement degradation. Concluding, struvite-forming cements might be promising bone replacement materials due to their good degradation which is coupled with new bone formation. Recently, the interest in magnesium phosphate cements (MPC) for bone substitution increased, as they exhibit high initial strength, comparably elevated degradation potential and the release of valuable magnesium ions. However, only few in vivo studies, mostly including non-load-bearing defects in small animals, have been performed to analyze the degradation and regeneration capability of MPC derived compounds. The present study examined the in vivo behavior of magnesiumammoniumphosphate hexahydrate (struvite) implants with different porosity in both mechanically loaded and non-loaded defects of merino sheep. For the first time, the effect of mechanical stimuli on the biological outcome of this clinically relevant replacement material is shown and directly compared to the conventional unloaded defect situation in a large animal model. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Bonasia, Davide Edoardo; Martin, James A; Marmotti, Antonio; Kurriger, Gail L; Lehman, Abigail D; Rossi, Roberto; Amendola, Annunziato
2016-12-01
The goal of the study was to evaluate the repair of chondral lesions treated with combined autologous adult/allogenic juvenile cartilage fragments, compared with isolated adult and isolated juvenile cartilage fragments. Fifty-eight adult (>16 week old) and five juvenile (<6 week old) New Zealand White female rabbits were used. A large osteochondral defect was created in the center of the femoral trochlea of adult rabbits. The rabbits were divided in four groups: Group 1 = untreated defects (controls); Group 2 = adult cartilage fragments; Group 3 = juvenile cartilage fragments; and Group 4 = adult + juvenile cartilage fragments. Killings were performed at 3 and 6 months. The defects were evaluated with ICRS macroscopic score, modified O'Driscoll score, and Collagen type II immunostaining. At 3 months, Group 4 performed better than Group 1, in terms of modified O'Driscoll score (p = 0.001) and Collagen type II immunostaining (p = 0.015). At 6 months, Group 4 showed higher modified O'Driscoll score (p = 0.003) and Collagen type II immunostaining score (p < 0.001) than Group 1. Histologically, also Group 3 performed better than Group 1 (p = 0.03), and Group 4 performed better than Group 2 (p = 0.004). Mixing adult and juvenile cartilage fragments improved cartilage repair in a rabbit model. In the clinical setting, a new "one-stage" procedure combining the two cartilage sources can be hypothesized, with the advantages of improved chondral repair and large defect coverage, because of the use of an off-the-shelf juvenile allograft. Further studies on larger animals and clinical trials are required to confirm these results.
Femoral head epiphysis growth and development among Chinese children aged 0-5 years.
Luo, Jiayou; Tang, Jin; Zhou, Libo; Zeng, Rong; Mou, Jinsong; Zhang, Lingli
2009-05-01
The aim of this study was to examine the pattern of femoral head epiphysis growth and development among Chinese children. Between January and December, 2007, we randomly sampled 1,450 healthy Chinese children (0-5 years old) from Hunan Provincial Children's Hospital in Changsha, Hunan, China. The diameter of femoral head epiphysis was measured by pelvic X-ray photography and processed by medical image processing software. The growth of femoral head epiphysis in girls was 2-3 months earlier than that in boys. The diameter of femoral head epiphysis increased with advancing age in both girls and boys, but the diameter of femoral head epiphysis in 2, 3, 4, 6, and 10-month-old girls was significantly larger than that in boys. Cubic regression equations between the diameter of femoral head epiphysis and age were created for boys and girls that could be used to predict the diameter of femoral head epiphysis. In conclusion, there was gender difference in femoral head epiphysis growth and development among Chinese children, and our prediction models will provide the guidance for early diagnosis of diseases related to the growth and development of the femoral head epiphysis.
NASA Astrophysics Data System (ADS)
Shi, X. H.; Jiang, W.; Chen, H. Z.; Zou, W.; Wang, W. D.; Guo, Z.; Luo, J. M.; Gu, Z. W.; Zhang, X. D.
2008-11-01
The mechanical behaviors of calcar-defected femur and restorations under physiological load are the key factors that will greatly influence the success of femur calcar defect repairing, especially the stress distribution on the bone-restoration interface. 3D finite elements analysis (FEA) was used to analyze the mechanical characters on the interfaces between femoral calcar defects and bone cement or HA restorations. Under the load of two times of a human weight (1436.03 N) and with the increase of the defect dimension from 6 mm to 12 mm, the maximal stresses on the surface of restorations are from 7.06 MPa to 11.89 MPa for bone cement and 2.97-9 MPa for HA separately. In this condition, HA restoration will probably be broken on the bone-restoration interface when the defect diameter is beyond 8 mm. Furthermore, under the load of 1.5 times of a human weight, HA restoration would not be safe unless the defect dimension is smaller than 10 mm, because the maximal stress (4.62 MPa) on the restoration is only a little lower than compressive strength of HA, otherwise the bone fixation device should be applied to ensure the safety. It is relatively safe for all restorations under all the tested defect sizes when the load is just the weight of a human body.
Rüdiger, Hannes A; Parvex, Valérie; Terrier, Alexandre
2016-03-01
Although the importance of accurate femoral reconstruction to achieve a good functional outcome is well documented, quantitative data on the effects of a displacement of the femoral center of rotation on moment arms are scarce. The purpose of this study was to calculate moment arms after nonanatomical femoral reconstruction. Finite element models of 15 patients including the pelvis, the femur, and the gluteal muscles were developed. Moment arms were calculated within the native anatomy and compared to distinct displacement of the femoral center of rotation (leg lengthening of 10 mm, loss of femoral offset of 20%, anteversion ±10°, and fixed anteversion at 15°). Calculations were performed within the range of motion observed during a normal gait cycle. Although with all evaluated displacements of the femoral center of rotation, the abductor moment arm remained positive, some fibers initially contributing to extension became antagonists (flexors) and vice versa. A loss of 20% of femoral offset led to an average decrease of 15% of abductor moment. Femoral lengthening and changes in femoral anteversion (±10°, fixed at 15°) led to minimal changes in abductor moment arms (maximum change of 5%). Native femoral anteversion correlated with the changes in moment arms induced by the 5 variations of reconstruction. Accurate reconstruction of offset is important to maintaining abductor moment arms, while changes of femoral rotation had minimal effects. Patients with larger native femoral anteversion appear to be more susceptible to femoral head displacements. Copyright © 2016 Elsevier Inc. All rights reserved.
Finite Element Analysis of Patella Alta: A Patellofemoral Instability Model.
Watson, Nicole A; Duchman, Kyle R; Grosland, Nicole M; Bollier, Matthew J
2017-01-01
This study aims to provide biomechanical data on the effect of patella height in the setting of medial patellofemoral ligament (MPFL) reconstruction using finite element analysis. The study will also examine patellofemoral joint biomechanics using variable femoral insertion sites for MPFL reconstruction. A previously validated finite element knee model was modified to study patella alta and baja by translating the patella a given distance to achieve each patella height ratio. Additionally, the models were modified to study various femoral insertion sites of the MPFL (anatomic, anterior, proximal, and distal) for each patella height model, resulting in 32 unique scenarios available for investigation. In the setting of patella alta, the patellofemoral contact area decreased, resulting in a subsequent increase in maximum patellofemoral contact pressures as compared to the scenarios with normal patellar height. Additionally, patella alta resulted in decreased lateral restraining forces in the native knee scenario as well as following MPFL reconstruction. Changing femoral insertion sites had a variable effect on patellofemoral contact pressures; however, distal and anterior femoral tunnel malpositioning in the setting of patella alta resulted in grossly elevated maximum patellofemoral contact pressures as compared to other scenarios. Patella alta after MPFL reconstruction results in decreased lateral restraining forces and patellofemoral contact area and increased maximum patellofemoral contact pressures. When the femoral MPFL tunnel is malpositioned anteriorly or distally on the femur, the maximum patellofemoral contact pressures increase with severity of patella alta. When evaluating patients with patellofemoral instability, it is important to recognize patella alta as a potential aggravating factor. Failure to address patella alta in the setting of MPFL femoral tunnel malposition may result in even further increases in patellofemoral contact pressures, making it essential to optimize intraoperative techniques to confirm anatomic MPFL femoral tunnel positioning.
Finite Element Analysis of Patella Alta: A Patellofemoral Instability Model
Duchman, Kyle R.; Grosland, Nicole M.; Bollier, Matthew J.
2017-01-01
Abstract Background: This study aims to provide biomechanical data on the effect of patella height in the setting of medial patellofemoral ligament (MPFL) reconstruction using finite element analysis. The study will also examine patellofemoral joint biomechanics using variable femoral insertion sites for MPFL reconstruction. Methods: A previously validated finite element knee model was modified to study patella alta and baja by translating the patella a given distance to achieve each patella height ratio. Additionally, the models were modified to study various femoral insertion sites of the MPFL (anatomic, anterior, proximal, and distal) for each patella height model, resulting in 32 unique scenarios available for investigation. Results: In the setting of patella alta, the patellofemoral contact area decreased, resulting in a subsequent increase in maximum patellofemoral contact pressures as compared to the scenarios with normal patellar height. Additionally, patella alta resulted in decreased lateral restraining forces in the native knee scenario as well as following MPFL reconstruction. Changing femoral insertion sites had a variable effect on patellofemoral contact pressures; however, distal and anterior femoral tunnel malpositioning in the setting of patella alta resulted in grossly elevated maximum patellofemoral contact pressures as compared to other scenarios. Conclusions: Patella alta after MPFL reconstruction results in decreased lateral restraining forces and patellofemoral contact area and increased maximum patellofemoral contact pressures. When the femoral MPFL tunnel is malpositioned anteriorly or distally on the femur, the maximum patellofemoral contact pressures increase with severity of patella alta. Clinical Relevance: When evaluating patients with patellofemoral instability, it is important to recognize patella alta as a potential aggravating factor. Failure to address patella alta in the setting of MPFL femoral tunnel malposition may result in even further increases in patellofemoral contact pressures, making it essential to optimize intraoperative techniques to confirm anatomic MPFL femoral tunnel positioning. PMID:28852343
Preininger, Bernd; Duda, Georg; Gerigk, Hinnerk; Bruckner, Jonas; Ellinghaus, Agnes; Sass, F. Andrea; Perka, Carsten; Schmidt-Bleek, Katharina; Dienelt, Anke
2013-01-01
Sufficient angiogenesis is crucial during tissue regeneration and therefore also pivotal in bone defect healing. Recently, peripheral blood derived progenitor cells have been identified to have in addition to their angiogenic potential also osteogenic characteristics, leading to the hypothesis that bone regeneration could be stimulated by local administration of these cells. The aim of this study was to evaluate the angiogenic potential of locally administered progenitor cells to improve bone defect healing. Cells were separated from the peripheral blood of donor animals using the markers CD34 and CD133. Results of the in vitro experiments confirmed high angiogenic potential in the CD133(+) cell group. CD34(+) and CD133(+) cells were tested in an in vivo rat femoral defect model of delayed healing for their positive effect on the healing outcome. An increased callus formation and higher bone mineral density of callus tissue was found after the CD133(+) cell treatment compared to the group treated with CD34(+) cells and the control group without cells. Histological findings confirmed an increase in vessel formation and mineralization at day 42 in the osteotomy gap after CD133(+) cell transplantation. The higher angiogenic potential of CD133(+) cells from the in vitro experients therefore correlates with the in vivo data. This study demonstrates the suitability of angiogenic precursors to further bone healing and gives an indication that peripheral blood is a promising source for progenitor cells circumventing the problems associated with bone marrow extraction. PMID:23457441
Mack, Andrew W; Helgeson, Melvin D; Tis, John E
2008-09-01
Combat-related blast injuries often cause devastating extremity trauma. We report a case of a 21-year-old male service member who sustained massive bilateral lower extremity trauma secondary to a blast injury. His orthopaedic injuries included a near traumatic disarticulation of the right knee and a left open type IIIB periarticular knee fracture with traumatic patellectomy, loss of the extensor mechanism, and segmental loss of the distal 11 cm of his femur. Definitive treatment of his injuries included a contralateral structural cortical femoral autograft which was implanted into the left knee segmental defect to facilitate knee fusion with an intramedullary knee fusion nail and a right transfemoral amputation. Radiographic evidence of solid fusion was obtained 8 months postoperatively. Currently, the patient is a community ambulator with the aid of his right lower extremity prosthetic limb and cane.
Lerch, M; Olender, G; von der Höh, N; Thorey, F; von Lewinski, G; Meyer-Lindenberg, A; Windhagen, H; Hurschler, C
2009-01-01
Microfractures of the femoral head during implantation of the femoral components are suspected to be a cause of fractures at the implant/neck junction which represent a common failure mode in hip resurfacing arthroplasty. Callus formation observed in femoral head retrievals suggests the occurrence of microfractures inside the femoral head, which might be inadvertently caused by the surgeon during implantation. The aim of this biomechanical study was to analyse whether or not the implantation of a cementless femoral component hip resurfacing system causes microfractures in the femoral head. After the preparation of 20 paired human cadaveric femoral heads, the cementless femoral component ESKA Typ BS (ESKA Implants GmbH & Co., Lübeck) was implanted on 9 specimens with an impaction device that generates 4.5 kN impaction force. On 9 specimens the femoral component was implanted by hand. One head was used as a fracture model, 1 specimen served as control without manipulation. The femoral component used for impaction was equipped with hinges to enable its removal without further interfering with the bone stock. Specimens were scanned with a microCT device before and after impaction and the microCT datasets before and after impaction were compared to identify possible microfractures. Twenty strikes per hand or with the impaction device provided sufficient implant seating. Neither the macroscopic examination nor the 2-dimensional microCT analysis revealed any fractures of the femoral heads after impaction. At least macroscopically and in the 2-dimensional microCT analysis, implantation of the cementless hip resurfacing femoral component ESKA Typ BS with 4.5 kN or by hand does not seem to cause fractures of the femoral head. Georg Thieme Verlag KG Stuttgart, New York.
Yim, Jung-Eun; Heshka, Stanley; Albu, Jeanine B.; Heymsfield, Steven; Gallagher, Dympna
2009-01-01
—Femoral-gluteal adipose tissue (AT) may be cardioprotective through fatty acids uptake. Femoral-gluteal AT has previously been defined as leg fat measured by dual energy x-ray absorptiometry (DXA); however, subcutaneous adipose tissue (SAT) and intermuscular adipose tissue (IMAT) are inseparable using DXA. This study investigated the independent relationships between femoral-gluteal SAT, femoral-gluteal IMAT, and cardiovascular disease (CVD) risk factors [fasting serum measures of glucose, total cholesterol (TC), high density lipoprotein cholesterol (HDLC), triglycerides (TG) and insulin] and whether race differences exist in femoral-gluteal AT distribution. Adult Caucasians (56 men and 104 women), African-Americans (37 men and 76 women), and Asians (11 men and 35 women) had total AT (TAT) including femoral-gluteal AT (upper leg SAT and IMAT) and visceral AT (VAT) by magnetic resonance imaging (MRI). General linear models identified the independent effects of femoral-gluteal SAT and femoral-gluteal IMAT on each risk factor after covarying for TAT, VAT, age, race, sex, and two-way interactions. Femoral-gluteal IMAT and glucose (P < 0.05) were positively associated independent of VAT. There were also significant inverse associations between femoral-gluteal SAT and insulin (P < 0.01) and TG (P < 0.05), although the addition of VAT rendered these effects nonsignificant, possibly due to collinearity. Asian women had less femoral-gluteal SAT and greater VAT than Caucasians and African-Americans (P < 0.05) and Asian and African-American men had greater femoral-gluteal IMAT than Caucasians, adjusted for age and TAT (P < 0.05 for both). Femoral-gluteal SAT and femoral-gluteal IMAT distribution varies by sex and race, and these two components have independent and opposing relationships with CVD risk factors. PMID:18079271
Kia, Mohammad; Wright, Timothy M; Cross, Michael B; Mayman, David J; Pearle, Andrew D; Sculco, Peter K; Westrich, Geoffrey H; Imhauser, Carl W
2018-01-01
The correct amount of external rotation of the femoral component during TKA is controversial because the resulting changes in biomechanical knee function associated with varying degrees of femoral component rotation are not well understood. We addressed this question using a computational model, which allowed us to isolate the biomechanical impact of geometric factors including bony shapes, location of ligament insertions, and implant size across three different knees after posterior-stabilized (PS) TKA. Using a computational model of the tibiofemoral joint, we asked: (1) Does external rotation unload the medial collateral ligament (MCL) and what is the effect on lateral collateral ligament tension? (2) How does external rotation alter tibiofemoral contact loads and kinematics? (3) Does 3° external rotation relative to the posterior condylar axis align the component to the surgical transepicondylar axis (sTEA) and what anatomic factors of the femoral condyle explain variations in maximum MCL tension among knees? We incorporated a PS TKA into a previously developed computational knee model applied to three neutrally aligned, nonarthritic, male cadaveric knees. The computational knee model was previously shown to corroborate coupled motions and ligament loading patterns of the native knee through a range of flexion. Implant geometries were virtually installed using hip-to-ankle CT scans through measured resection and anterior referencing surgical techniques. Collateral ligament properties were standardized across each knee model by defining stiffness and slack lengths based on the healthy population. The femoral component was externally rotated from 0° to 9° relative to the posterior condylar axis in 3° increments. At each increment, the knee was flexed under 500 N compression from 0° to 90° simulating an intraoperative examination. The computational model predicted collateral ligament forces, compartmental contact forces, and tibiofemoral internal/external and varus-valgus rotation through the flexion range. The computational model predicted that femoral component external rotation relative to the posterior condylar axis unloads the MCL and the medial compartment; however, these effects were inconsistent from knee to knee. When the femoral component was externally rotated by 9° rather than 0° in knees one, two, and three, the maximum force carried by the MCL decreased a respective 55, 88, and 297 N; the medial contact forces decreased at most a respective 90, 190, and 570 N; external tibial rotation in early flexion increased by a respective 4.6°, 1.1°, and 3.3°; and varus angulation of the tibia relative to the femur in late flexion increased by 8.4°, 8.0°, and 7.9°, respectively. With 3° of femoral component external rotation relative to the posterior condylar axis, the femoral component was still externally rotated by up to 2.7° relative to the sTEA in these three neutrally aligned knees. Variations in MCL force from knee to knee with 3° of femoral component external rotation were related to the ratio of the distances from the femoral insertion of the MCL to the posterior and distal cuts of the implant; the closer this ratio was to 1, the more uniform were the MCL tensions from 0° to 90° flexion. A larger ratio of distances from the femoral insertion of the MCL to the posterior and distal cuts may cause clinically relevant increases in both MCL tension and compartmental contact forces. To obtain more consistent ligament tensions through flexion, it may be important to locate the posterior and distal aspects of the femoral component with respect to the proximal insertion of the MCL such that a ratio of 1 is achieved.
Amstutz, Harlan C; Takamura, Karren M; Le Duff, Michel J
2011-04-01
The results of metal-on-metal hip Conserve® Plus resurfacings with up to 14 years of follow-up with and without risk factors of small component size and/or large femoral defects were compared as performed with either first- or second-generation surgical techniques. There was a 99.7% survivorship at ten years for ideal hips (large components and small defects) and a 95.3% survivorship for hips with risk factors optimized technique has measurably improved durability in patients with risk factors at the 8-year mark. The lessons learned can help offset the observed learning curve of resurfacing. Copyright © 2011 Elsevier Inc. All rights reserved.
Transfer of obturator nerve for femoral nerve injury: an experiment study in rats.
Meng, Depeng; Zhou, Jun; Lin, Yaofa; Xie, Zheng; Chen, Huihao; Yu, Ronghua; Lin, Haodong; Hou, Chunlin
2018-07-01
Quadriceps palsy is mainly caused by proximal lesions in the femoral nerve. The obturator nerve has been previously used to repair the femoral nerve, although only a few reports have described the procedure, and the outcomes have varied. In the present study, we aimed to confirm the feasibility and effectiveness of this treatment in a rodent model using the randomized control method. Sixty Sprague-Dawley rats were randomized into two groups: the experimental group, wherein rats underwent femoral neurectomy and obturator nerve transfer to the femoral nerve motor branch; and the control group, wherein rats underwent femoral neurectomy without nerve transfer. Functional outcomes were measured using the BBB score, muscle mass, and histological assessment. At 12 and 16 weeks postoperatively, the rats in the experimental group exhibited recovery to a stronger stretch force of the knee and higher BBB score, as compared to the control group (p < 0.05). The muscle mass and myofiber cross-sectional area of the quadriceps were heavier and larger than those in the control group (p < 0.05). A regenerated nerve with myelinated and unmyelinated fibers was observed in the experimental group. No significant differences were observed between groups at 8 weeks postoperatively (p > 0.05). Obturator nerve transfer for repairing femoral nerve injury was feasible and effective in a rat model, and can hence be considered as an option for the treatment of femoral nerve injury.
NASA Technical Reports Server (NTRS)
van der Meulen, M. C.; Marcus, R.; Bachrach, L. K.; Carter, D. R.
1997-01-01
We have developed an analytical model of long bone cross-sectional ontogeny in which appositional growth of the diaphysis is primarily driven by mechanical stimuli associated with increasing body mass during growth and development. In this study, our goal was to compare theoretical predictions of femoral diaphyseal structure from this model with measurements of femoral bone mineral and geometry by dual energy x-ray absorptiometry. Measurements of mid-diaphyseal femoral geometry and structure were made previously in 101 Caucasian adolescents and young adults 9-26 years of age. The data on measured bone mineral content and calculated section modulus were compared with the results of our analytical model of cross-sectional development of the human femur over the same age range. Both bone mineral content and section modulus showed good correspondence with experimental measurements when the relationships with age and body mass were examined. Strong linear relationships were evident for both parameters when examined as a function of body mass.
Femoral curvature variability in modern humans using three-dimensional quadric surface fitting.
Chapman, Tara; Sholukha, Victor; Semal, Patrick; Louryan, Stéphane; Rooze, Marcel; Van Sint Jan, Serge
2015-12-01
This study analysed femoral curvature in a population from Belgium in conjunction with other morphological characteristics by the use of three-dimensional (3D) quadric surfaces (QS) modelled from the bone surface. 3D models were created from computed tomography data of 75 femoral modern human bones. Anatomical landmarks (ALs) were palpated in specific bony areas of the femur (shaft, condyles, neck and head). QS were then created from the surface vertices which enclose these ALs. The diaphyseal shaft was divided into five QS shapes to analyse curvature in different parts of the shaft. Femoral bending differs in different parts of the diaphyseal shaft. The greatest degree of curvature was found in the distal shaft (mean 4.5° range 0.2°-10°) followed by the proximal (mean 4.4° range 1.5°-10.2°), proximal intermediate (mean 3.7° range 0.9°-7.9°) and distal intermediate (mean 1.8° range 0.2°-5.6°) shaft sections. The proximal and distal angles were significantly more bowed than the intermediate proximal and the intermediate distal angle. There was no significant difference between the proximal and distal angle. No significant correlations were found between morphological characteristics and femoral curvature. An extremely large variability of femoral curvature with several bones displaying very high or low degrees of femoral curvature was also found. 3D QS fitting enables the creation of accurate models which can discriminate between different patterns in similar curvatures and demonstrates there is a clear difference between curvature in different parts of the shaft.
Khanal, Laxman; Shah, Sandip; Koirala, Sarun
2017-03-01
Length of long bones is taken as an important contributor for estimating one of the four elements of forensic anthropology i.e., stature of the individual. Since physical characteristics of the individual differ among different groups of population, population specific studies are needed for estimating the total length of femur from its segment measurements. Since femur is not always recovered intact in forensic cases, it was the aim of this study to derive regression equations from measurements of proximal and distal fragments in Nepalese population. A cross-sectional study was done among 60 dry femora (30 from each side) without sex determination in anthropometry laboratory. Along with maximum femoral length, four proximal and four distal segmental measurements were measured following the standard method with the help of osteometric board, measuring tape and digital Vernier's caliper. Bones with gross defects were excluded from the study. Measured values were recorded separately for right and left side. Statistical Package for Social Science (SPSS version 11.5) was used for statistical analysis. The value of segmental measurements were different between right and left side but statistical difference was not significant except for depth of medial condyle (p=0.02). All the measurements were positively correlated and found to have linear relationship with the femoral length. With the help of regression equation, femoral length can be calculated from the segmental measurements; and then femoral length can be used to calculate the stature of the individual. The data collected may contribute in the analysis of forensic bone remains in study population.
Devane, P A; Horne, J G; Foley, G; Stanley, J
2017-10-01
This paper describes the methodology, validation and reliability of a new computer-assisted method which uses models of the patient's bones and the components to measure their migration and polyethylene wear from radiographs after total hip arthroplasty (THA). Models of the patient's acetabular and femoral component obtained from the manufacturer and models of the patient's pelvis and femur built from a single computed tomography (CT) scan, are used by a computer program to measure the migration of the components and the penetration of the femoral head from anteroposterior and lateral radiographs taken at follow-up visits. The program simulates the radiographic setup and matches the position and orientation of the models to outlines of the pelvis, the acetabular and femoral component, and femur on radiographs. Changes in position and orientation reflect the migration of the components and the penetration of the femoral head. Validation was performed using radiographs of phantoms simulating known migration and penetration, and the clinical feasibility of measuring migration was assessed in two patients. Migration of the acetabular and femoral components can be measured with limits of agreement (LOA) of 0.37 mm and 0.33 mm, respectively. Penetration of the femoral head can be measured with LOA of 0.161 mm. The migration of components and polyethylene wear can be measured without needing specialised radiographs. Accurate measurement may allow earlier prediction of failure after THA. Cite this article: Bone Joint J 2017;99-B:1290-7. ©2017 The British Editorial Society of Bone & Joint Surgery.
Computation of Femoral Canine Morphometric Parameters in Three-Dimensional Geometrical Models.
Savio, Gianpaolo; Baroni, Teresa; Concheri, Gianmaria; Baroni, Ermenegildo; Meneghello, Roberto; Longo, Federico; Isola, Maurizio
2016-11-01
To define and validate a method for the measurement of 3-dimensional (3D) morphometric parameters in polygonal mesh models of canine femora. Ex vivo/computerized model. Sixteen femora from 8 medium to large-breed canine cadavers (mean body weight 28.3 kg, mean age 5.3 years). Femora were measured with a 3D scanner, obtaining 3D meshes. A computer-aided design-based (CAD) software tool was purposely developed, which allowed automatic calculation of morphometric parameters on a mesh model. Anatomic and mechanical lateral proximal femoral angles (aLPFA and mLPFA), anatomic and mechanical lateral distal femoral angles (aLDFA and mLDFA), femoral neck angle (FNA), femoral torsion angle (FTA), and femoral varus angle (FVA) were measured in 3D space. Angles were also measured onto projected planes and radiographic images. Mean (SD) femoral angles (degrees) measured in 3D space were: aLPFA 115.2 (3.9), mLPFA 105.5 (4.2), aLDFA 88.6 (4.5), mLDFA 93.4 (3.9), FNA 129.6 (4.3), FTA 45 (4.5), and FVA -1.4 (4.5). Onto projection planes, aLPFA was 103.7 (5.9), mLPFA 98.4 (5.3), aLDFA 88.3 (5.5), mLDFA 93.6 (4.2), FNA 132.1 (3.5), FTA 19.1 (5.7), and FVA -1.7 (5.5). With radiographic imaging, aLPFA was 109.6 (5.9), mLPFA 105.3 (5.2), aLDFA 92.6 (3.8), mLDFA 96.9 (2.9), FNA 120.2 (8.0), FTA 30.2 (5.7), and FVA 2.6 (3.8). The proposed method gives reliable and consistent information about 3D bone conformation. Results are obtained automatically and depend only on femur morphology, avoiding any operator-related bias. Angles in 3D space are different from those measured with standard radiographic methods, mainly due to the different definition of femoral axes. © Copyright 2016 by The American College of Veterinary Surgeons.
Kluess, Daniel; Mittelmeier, Wolfram; Bader, Rainer
2010-12-01
In connection with technological advances in the manufacturing of medical ceramics, a newly developed ceramic femoral component was introduced in total knee arthroplasty. We generated an explicit finite-element-model to calculate the stresses developed under the highly dynamic intraoperative impaction with regard to cobalt-chromium and ceramic implant material as well as application of a silicone cover in order to reduce stress. The impaction was calculated with the hammer hitting the backside of the impactor at previously measured initial velocities. Subsequently the impactor, consisting of a steel handhold and a polyoxymethylene head, hit the femoral component. Instead of modelling femoral bone, the implant was mounted on four spring elements with spring constants previously determined in an experimental impaction model. The maximum principal stresses in the implants were evaluated at 8000 increments during the first 4 ms of impact. The ceramic implant showed principal stresses 10% to 48% higher than the cobalt chromium femoral component. The simulation of a 5mm thick silicone layer between the impactor and the femoral component showed a strong decrease of vibration resulting in a reduction of 54% to 68% of the maximum stress amounts. The calculated amounts of principal stress were beneath the ultimate bending strengths of each material. Based on the results, intraoperative fracture of femoral components in total knee replacement may not be caused solely by impaction, but also by contributing geometrical factors such as inadequate preparation of the distal femur. In order to minimize the influence of impaction related stress peaks we recommend limiting the velocity as well as the weight of the impaction hammer when inserting femoral components. The silicone cover seems to deliver a strong decrease of implant stress and should be considered in surgery technique in the future. Copyright © 2010 Elsevier Ltd. All rights reserved.
Fink, Bernd; Schlumberger, Michael; Oremek, Damian
2017-08-01
The treatment of periprosthetic infections of hip arthroplasties typically involves use of either a single- or two-stage (with implantation of a temporary spacer) revision surgery. In patients with severe acetabular bone deficiencies, either already present or after component removal, spacers cannot be safely implanted. In such hips where it is impossible to use spacers and yet a two-stage revision of the prosthetic stem is recommended, we have combined a two-stage revision of the stem with a single revision of the cup. To our knowledge, this approach has not been reported before. (1) What proportion of patients treated with single-stage acetabular reconstruction as part of a two-stage revision for an infected THA remain free from infection at 2 or more years? (2) What are the Harris hip scores after the first stage and at 2 years or more after the definitive reimplantation? Between June 2009 and June 2014, we treated all patients undergoing surgical treatment for an infected THA using a single-stage acetabular revision as part of a two-stage THA exchange if the acetabular defect classification was Paprosky Types 2B, 2C, 3A, 3B, or pelvic discontinuity and a two-stage procedure was preferred for the femur. The procedure included removal of all components, joint débridement, definitive acetabular reconstruction (with a cage to bridge the defect, and a cemented socket), and a temporary cemented femoral component at the first stage; the second stage consisted of repeat joint and femoral débridement and exchange of the femoral component to a cementless device. During the period noted, 35 patients met those definitions and were treated with this approach. No patients were lost to followup before 2 years; mean followup was 42 months (range, 24-84 months). The clinical evaluation was performed with the Harris hip scores and resolution of infection was assessed by the absence of clinical signs of infection and a C-reactive protein level less than 10 mg/L. All patients were assessed before surgery, between stages, every 3 months during the first year after surgery, every 6 months during the second year postoperative, and at latest followup, and were retrospectively drawn from a longitudinally maintained institutional database. Thirty-four of 35 patients (97.2%; 95% CI, 85.4%-99.5%) appeared free of infection by criteria of Masri et al. and Zimmerli et al. at latest followup. The Harris hip score was 61 ± 13 points after the first operation and 82 ± 16 points 2 years after the second operation. This technique is a promising treatment option for periprosthetic infections of the hip in which substantial acetabular defects exclude implantation of a normal spacer and a two-stage revision of the femoral component is favored. Level IV, therapeutic study.
Orth, Patrick; Duffner, Julia; Zurakowski, David; Cucchiarini, Magali; Madry, Henning
2016-01-01
Microfracture is the most commonly applied arthroscopic marrow stimulation procedure. Articular cartilage repair is improved when the subchondral bone is perforated by small-diameter microfracture awls compared with larger awls. Controlled laboratory study. Standardized rectangular (4 × 8 mm) full-thickness chondral defects (N = 24) were created in the medial femoral condyle of 16 adult sheep and debrided down to the subchondral bone plate. Three treatment groups (n = 8 defects each) were tested: 6 microfracture perforations using small-diameter awls (1.0 mm; group 1), large-diameter awls (1.2 mm; group 2), or without perforations (debridement control; group 3). Osteochondral repair was assessed at 6 months in vivo using established macroscopic, histological, immunohistochemical, biochemical, and micro-computed tomography analyses. Compared with control defects, histological cartilage repair was always improved after both microfracture techniques (P < .023). Application of 1.0-mm microfracture awls led to a significantly improved histological overall repair tissue quality (7.02 ± 0.70 vs 9.03 ± 0.69; P = .008) and surface grading (1.05 ± 0.28 vs 2.10 ± 0.19; P = .001) compared with larger awls. The small-diameter awl decreased relative bone volume of the subarticular spongiosa (bone volume/tissue volume ratio: 23.81% ± 3.37% vs 30.58% ± 2.46%; P = .011). Subchondral bone cysts and intralesional osteophytes were frequently observed after either microfracture treatment. Macroscopic grading, DNA, proteoglycan, and type I and type II collagen contents as well as degenerative changes within the adjacent cartilage remained unaffected by the awl diameter. Small-diameter microfracture awls improve articular cartilage repair in the translational sheep model more effectively than do larger awls. These data support the use of small microfracture instruments for the surgical treatment of cartilage defects and warrant prolonged clinical investigations. © 2015 The Author(s).
Socket position determines hip resurfacing 10-year survivorship.
Amstutz, Harlan C; Le Duff, Michel J; Johnson, Alicia J
2012-11-01
Modern metal-on-metal hip resurfacing arthroplasty designs have been used for over a decade. Risk factors for short-term failure include small component size, large femoral head defects, low body mass index, older age, high level of sporting activity, and component design, and it is established there is a surgeon learning curve. Owing to failures with early surgical techniques, we developed a second-generation technique to address those failures. However, it is unclear whether the techniques affected the long-term risk factors. We (1) determined survivorship for hips implanted with the second-generation cementing technique; (2) identified the risk factors for failure in these patients; and (3) determined the effect of the dominant risk factors on the observed modes of failure. We retrospectively reviewed the first 200 hips (178 patients) implanted using our second-generation surgical technique, which consisted of improvements in cleaning and drying the femoral head before and during cement application. There were 129 men and 49 women. Component orientation and contact patch to rim distance were measured. We recorded the following modes of failure: femoral neck fracture, femoral component loosening, acetabular component loosening, wear, dislocation, and sepsis. The minimum followup was 25 months (mean, 106.5 months; range, 25-138 months). Twelve hips were revised. Kaplan-Meier survivorship was 98.0% at 5 years and 94.3% at 10 years. The only variable associated with revision was acetabular component position. Contact patch to rim distance was lower in hips that dislocated, were revised for wear, or were revised for acetabular loosening. The dominant modes of failure were related to component wear or acetabular component loosening. Acetabular component orientation, a factor within the surgeon's control, determines the long-term success of our current hip resurfacing techniques. Current techniques have changed the modes of failure from aseptic femoral failure to wear or loosening of the acetabular component. Level III, prognostic study. See Guidelines for Authors for a complete description of levels of evidence.
Zhang, Yijia; Jia, Zhenshan; Yuan, Hongjiang; Dusad, Anand; Ren, Ke; Wei, Xin; Fehringer, Edward V.; Purdue, P. Edward; Daluiski, Aaron; Goldring, Steven R.; Wang, Dong
2016-01-01
Purpose To evaluate the therapeutic efficiency of a micellar prodrug formulation of simvastatin (SIM/SIM-mPEG) and explore its safety in a closed femoral fracture mouse model. Methods The amphiphilic macromolecular prodrug of simvastatin (SIM-mPEG) was synthesized and formulated together with free simvastatin into micelles. It was also labeled with a near infrared dye for in vivo imaging purpose. A closed femoral fracture mouse model was established using a three-point bending device. The mice with established closed femoral fracture were treated with SIM/SIM-mPEG micelle, using free simvastatin and saline as controls. The therapeutic efficacy of the micelles was evaluated using a high-resolution micro-CT. Serum biochemistry and histology analyses were performed to explore the potential toxicity of the micelle formulation. Results Near Infrared Fluorescence (NIRF) imaging confirmed the passive targeting of SIM/SIM-mPEG micelles to the bone lesion of the mice with closed femoral fracture. The micelle was found to promote fracture healing with an excellent safety profile. In addition, the accelerated healing of the femoral fracture also helped to prevent disuse-associated same-side tibia bone loss accompanying the femur fracture. Conclusion SIM/SIM-mPEG micelle was found to be an effective and safe treatment for closed femoral fracture repair in mice. The evidence obtained in this study suggests that it may have the potential to be translated into a novel therapy for clinical management of skeletal fractures and non-union. PMID:27164897
Femoral Access and Delivery of Continuous Renal Replacement Therapy Dose.
Bellomo, Rinaldo; Mårtensson, Johan; Lo, Serigne; Kaukonen, Kirsi-Maija; Cass, Alan; Gallagher, Martin
2016-01-01
The study aims to describe the use of dialysis catheters in critically ill patients treated with continuous renal replacement therapy (CRRT) and to study the impact of femoral versus non-femoral access on CRRT dose. Statistical analysis and predictive modelling of data from the Randomized Evaluation of Normal vs. Augmented Level renal replacement therapy trial. The femoral vein was the first access site in 937 (67%) of 1,399 patients. These patients had higher Acute Physiology and Chronic Health Evaluation and Sequential Organ Failure Assessment scores (p = 0.009) and lower pH (p < 0.001) but similar mortality to patients with non-femoral access (44 vs. 45%; p = 0.63). Lower body weight was independently associated with femoral access placement (OR 0.97, 95% CI 0.96-0.98). Femoral access was associated with a 1.03% lower CRRT dose (p = 0.05), but a 4.20% higher dose was achieved with 13.5 Fr catheters (p = 0.03). Femoral access was preferred in lighter and sicker patients. Catheter gauge had greater impact than catheter site in CRRT dose delivery. Video Journal Club "Cappuccino with Claudio Ronco" at http://www.karger.com/?doi=439581. © 2015 S. Karger AG, Basel.
Benefit of cup medialization in total hip arthroplasty is associated with femoral anatomy.
Terrier, Alexandre; Levrero Florencio, Francesc; Rüdiger, Hannes A
2014-10-01
Medialization of the cup with a respective increase in femoral offset has been proposed in THA to increase abductor moment arms. Insofar as there are potential disadvantages to cup medialization, it is important to ascertain whether the purported biomechanical benefits of cup medialization are large enough to warrant the downsides; to date, studies regarding this question have disagreed. The purpose of this study was to quantify the effect of cup medialization with a compensatory increase in femoral offset compared with anatomic reconstruction for patients undergoing THA. We tested the hypothesis that there is a (linear) correlation between preoperative anatomic parameters and muscle moment arm increase caused by cup medialization. Fifteen patients undergoing THA were selected, covering a typical range of preoperative femoral offsets. For each patient, a finite element model was built based on a preoperative CT scan. The model included the pelvis, femur, gluteus minimus, medius, and maximus. Two reconstructions were compared: (1) anatomic position of the acetabular center of rotation, and (2) cup medialization compensated by an increase in the femoral offset. Passive abduction-adduction and flexion-extension were simulated in the range of normal gait. Muscle moment arms were evaluated and correlated to preoperative femoral offset, acetabular offset, height of the greater trochanter (relative to femoral center of rotation), and femoral antetorsion angle. The increase of muscle moment arms caused by cup medialization varied among patients. Muscle moment arms increase by 10% to 85% of the amount of cup medialization for abduction-adduction and from -35% (decrease) to 50% for flexion-extension. The change in moment arm was inversely correlated (R(2) = 0.588, p = 0.001) to femoral antetorsion (anteversion), such that patients with less femoral antetorsion gained more in terms of hip muscle moments. No linear correlation was observed between changes in moment arm and other preoperative parameters in this series. The benefit of cup medialization is variable and depends on the individual anatomy. Cup medialization with compensatory increase of the femoral offset may be particularly effective in patients with less femoral antetorsion. However, cup medialization must be balanced against its tradeoffs, including the additional loss of medial acetabular bone stock, and eventual proprioceptive implications of the nonanatomic center of rotation and perhaps joint reaction forces. Clinical studies should better determine the relevance of small changes of moment arms on function and joint reaction forces.
Identifying diversion of inferior vena cava after repair of atrial septal defect.
Lee, Yi Wei; Lee, Wei Chieh; Chua, Sarah
2015-10-01
Inadvertent IVC diversion into left atrium is a rare morbidity following ASD repair. Reported risk factors included a large secundum, or low-lying ASD, or inferior sinus venosus defect, and anomalous pulmonary connection into the RA. In our case, transesophageal echocardiogram showed abnormal connection of IVC to LA, but could not be identified owing to limited window. Cardiac CT could offer better anatomic clarification. On contrast transesophageal echocardiogram with agitated saline injected via right femoral vein, an abnormal right-to-left shunt was demonstrated by transit of microbubbles from IVC into LA, while majority of rest entered into the RA. Therefore, we confirm the IVC diversion into LA. Detection of such unusual condition is a challenge due to the fact that special echocardiographic windows are often needed.
Flatz, K M; Glaser, C; Flatz, W H; Reiser, M F; Matis, U
2014-01-01
The aim of our study was to implement and test an imaging protocol for the detection and evaluation of standardised cartilage defects using high-field magnetic resonance imaging (MRI) and to determine its limitations. A total of 84 cartilage defects were created in the femoral condyles of euthanized dogs with a minimum body mass of 25 kg. The cartilage defects had a depth of 0.3 to 1.0 mm and a diameter of 1 to 5 mm. T1-FLASH-3D-WE-sequences with an isotropic voxel size of 0.5 x 0.5 x 0.5 mm and an anisotropic voxel size of 0.3 x 0.3 x 0.8 mm were used. In addition to quantitative evaluation of the cartilage defects, the sig- nal intensities, signal-to-noise ratios and contrast-to-noise ratios of the cartilage were determined. Of special interest were the limita- tions in identifying and delineating the standardised cartilage defects. With the anisotropic voxel size, more cartilage defects were detectable. Our results demonstrated that cartilage defects as small as 3.0 mm in diameter and 0.4 mm in depth were reliably detected using anisotropic settings. Cartilage defects below this size were not reliably detected. We found that for optimal delineation of the joint cartilage and associated defects, a higher in-plane resolution with a larger slice thickness should be used, corresponding to the anisotropic settings employed in this study. For the delineation of larger cartilage defects, both the anisotropic and isotropic imaging methods can be used.
Henrich, D; Seebach, C; Verboket, R; Schaible, A; Marzi, I; Bonig, H
2018-03-06
Bone marrow mononuclear cells (BMC) seeded on a scaffold of β-tricalcium phosphate (β-TCP) promote bone healing in a critical-size femur defect model. Being BMC a mixed population of predominantly mature haematopoietic cells, which cell type(s) is(are) instrumental for healing remains elusive. Although clinical therapies using BMC are often dubbed as stem cell therapies, whether stem cells are relevant for the therapeutic effects is unclear and, at least in the context of bone repair, seems dubious. Instead, in light of the critical contribution of monocytes and macrophages to tissue development, homeostasis and injury repair, in the current study it was hypothesised that BMC-mediated bone healing derived from the stem cell population. To test this hypothesis, bone remodelling studies were performed in an established athymic rats critical-size femoral defect model, with β-TCP scaffolds augmented with complete BMC or BMC immunomagnetically depleted of stem cells (CD34+) or monocytes/macrophages (CD14+). Bone healing was assessed 8 weeks after transplantation. Compared to BMC-augmented controls, when CD14- BMC, but not CD34- BMC were transplanted into the bone defect, femora possessed dramatically decreased biomechanical stability and new bone formation was markedly reduced, as measured by histology. The degree of vascularisation did not differ between the two groups. It was concluded that the monocyte fraction within the BMC provided critical osteo-inductive cues during fracture healing. Which factors were responsible at the molecular levels remained elusive. However, this study marked a significant progress towards elucidating the mechanisms by which BMC elicit their therapeutic effects, at least in bone regeneration.
NASA Technical Reports Server (NTRS)
Werner, Christopher R.; Mulugeta, Lealem; Myers, J. G.; Pennline, J. A.
2015-01-01
NASA's Digital Astronaut Project (DAP) has developed a bone remodeling model that has been validated for predicting volumetric bone mineral density (vBMD) changes of trabecular and cortical bone in the absence of mechanical loading. The model was recently updated to include skeletal loading from exercise and free living activities to maintain healthy bone using a new daily load stimulus (DLS). This new formula was developed based on an extensive review of existing DLS formulas, as discussed in the abstract by Pennline et al. The DLS formula incorporated into the bone remodeling model utilizes strains and stress calculated from finite element model (FEM) of the bone region of interest. The proximal femur was selected for the initial application of the DLS formula, with a specific focus on the femoral neck. METHODS: The FEM was generated from CAD geometry of a femur using de-identified CT data. The femur was meshed using linear tetrahedral elements Figure (1) with higher mesh densities in the femoral neck region, which is the primary region of interest for the initial application of the DLS formula in concert with the DAP bone remodeling model. Nodal loads were applied to the femoral head and the greater trochanter and the base of the femur was held fixed. An L2 norm study was conducted to reduce the length of the femoral shaft without significantly impacting the stresses in the femoral neck. The material properties of the FEM of the proximal femur were separated between cortical and trabecular regions to work with the bone remodeling model. Determining the elements with cortical material properties in the FEM was based off of publicly available CT hip scans [4] that were segmented, cleaned, and overlaid onto the FEM.
Proximal femoral anatomy and collared stems in hip arthroplasty: is a single collar size sufficient?
Bonin, Nicolas; Gedouin, Jean-Emmanuel; Pibarot, Vincent; Bejui-Hughues, Jacques; Bothorel, Hugo; Saffarini, Mo; Batailler, Cécile
2017-10-03
Even if the benefits of collars are unclear, they remain widely used, in several femoral stem designs. This study aimed to determine whether collar size should be proportional to hip dimensions and morphology. The hypothesis was that the collar should be larger for greater stem sizes and for varus femoral necks. Computed Tomography scans of 204 healthy hips were digitally analysed and manually templated to determine principle dimensions, appropriate stem size and model, as well as cortical distance at the femoral calcar (ideal collar size). Univariable analysis revealed that cortical distance was moderately correlated with mediolateral offset (r = 0.572; p < 0.0001) and stem model (r = 0.520; p < 0.0001). Cortical distance was weakly correlated with head diameter (r = 0.399; p < 0.0001), stem size (r = 0.200; p = 0.017), and patient gender (r = 0.361; p < 0.0001). Multivariable analysis confirmed that stem model (p < 0.0001) and head diameter (p = 0.0162) are directly correlated to cortical distance. We found that cortical distance along the femoral calcar is directly correlated with the model of the stem implanted ('standard' or 'varus') and with the head diameter. This cortical distance indicates optimal collar size, which would grant maximum calcar coverage without prosthetic overhang. Collar size should be proportional to the size of the operated hip, and should be larger for 'varus' stem models than for 'standard' stem models.
Mumme, Marcus; Barbero, Andrea; Miot, Sylvie; Wixmerten, Anke; Feliciano, Sandra; Wolf, Francine; Asnaghi, Adelaide M; Baumhoer, Daniel; Bieri, Oliver; Kretzschmar, Martin; Pagenstert, Geert; Haug, Martin; Schaefer, Dirk J; Martin, Ivan; Jakob, Marcel
2016-10-22
Articular cartilage injuries have poor repair capacity, leading to progressive joint damage, and cannot be restored predictably by either conventional treatments or advanced therapies based on implantation of articular chondrocytes. Compared with articular chondrocytes, chondrocytes derived from the nasal septum have superior and more reproducible capacity to generate hyaline-like cartilage tissues, with the plasticity to adapt to a joint environment. We aimed to assess whether engineered autologous nasal chondrocyte-based cartilage grafts allow safe and functional restoration of knee cartilage defects. In a first-in-human trial, ten patients with symptomatic, post-traumatic, full-thickness cartilage lesions (2-6 cm 2 ) on the femoral condyle or trochlea were treated at University Hospital Basel in Switzerland. Chondrocytes isolated from a 6 mm nasal septum biopsy specimen were expanded and cultured onto collagen membranes to engineer cartilage grafts (30 × 40 × 2 mm). The engineered tissues were implanted into the femoral defects via mini-arthrotomy and assessed up to 24 months after surgery. Primary outcomes were feasibility and safety of the procedure. Secondary outcomes included self-assessed clinical scores and MRI-based estimation of morphological and compositional quality of the repair tissue. This study is registered with ClinicalTrials.gov, number NCT01605201. The study is ongoing, with an approved extension to 25 patients. For every patient, it was feasible to manufacture cartilaginous grafts with nasal chondrocytes embedded in an extracellular matrix rich in glycosaminoglycan and type II collagen. Engineered tissues were stable through handling with forceps and could be secured in the injured joints. No adverse reactions were recorded and self-assessed clinical scores for pain, knee function, and quality of life were improved significantly from before surgery to 24 months after surgery. Radiological assessments indicated variable degrees of defect filling and development of repair tissue approaching the composition of native cartilage. Hyaline-like cartilage tissues, engineered from autologous nasal chondrocytes, can be used clinically for repair of articular cartilage defects in the knee. Future studies are warranted to assess efficacy in large controlled trials and to investigate an extension of indications to early degenerative states or to other joints. Deutsche Arthrose-Hilfe. Copyright © 2016 Elsevier Ltd. All rights reserved.
Goebel, L; Orth, P; Cucchiarini, M; Pape, D; Madry, H
2017-04-01
To correlate osteochondral repair assessed by validated macroscopic scoring systems with established semiquantitative histological analyses in an ovine model and to test the hypothesis that important macroscopic individual categories correlate with their corresponding histological counterparts. In the weight-bearing portion of medial femoral condyles (n = 38) of 19 female adult Merino sheep (age 2-4 years; weight 70 ± 20 kg) full-thickness chondral defects were created (size 4 × 8 mm; International Cartilage Repair Society (ICRS) grade 3C) and treated with Pridie drilling. After sacrifice, 1520 blinded macroscopic observations from three observers at 2-3 time points including five different macroscopic scoring systems demonstrating all grades of cartilage repair where correlated with corresponding categories from 418 blinded histological sections. Categories "defect fill" and "total points" of different macroscopic scoring systems correlated well with their histological counterparts from the Wakitani and Sellers scores (all P ≤ 0.001). "Integration" was assessed in both histological scoring systems and in the macroscopic ICRS, Oswestry and Jung scores. Here, a significant relationship always existed (0.020 ≤ P ≤ 0.049), except for Wakitani and Oswestry (P = 0.054). No relationship was observed for the "surface" between histology and macroscopy (all P > 0.05). Major individual morphological categories "defect fill" and "integration", and "total points" of macroscopic scoring systems correlate with their corresponding categories in elementary and complex histological scoring systems. Thus, macroscopy allows to precisely predict key histological aspects of articular cartilage repair, underlining the specific value of macroscopic scoring for examining cartilage repair. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
3D-Printed Patient-Specific ACL Femoral Tunnel Guide from MRI.
Rankin, Iain; Rehman, Haroon; Frame, Mark
2018-01-01
Traditional ACL reconstruction with non-anatomic techniques can demonstrate unsatisfactory long-term outcomes with regards instability and the degenerative knee changes observed with these results. Anatomic ACL reconstruction attempts to closely reproduce the patient's individual anatomic characteristics with the aim of restoring knee kinematics, in order to improve patient short and long-term outcomes. We designed an arthroscopic, patient-specific, ACL femoral tunnel guide to aid anatomical placement of the ACL graft within the femoral tunnel. The guide design was based on MRI scan of the subject's uninjured contralateral knee, identifying the femoral footprint and its anatomical position relative to the borders of the femoral articular cartilage. Image processing software was used to create a 3D computer aided design which was subsequently exported to a 3D-printing service. Transparent acrylic based photopolymer, PA220 plastic and 316L stainless steel patient-specific ACL femoral tunnel guides were created; the models produced were accurate with no statistical difference in size and positioning of the center of the ACL femoral footprint guide to MRI ( p =0.344, p =0.189, p =0.233 respectively). The guides aim to provide accurate marking of the starting point of the femoral tunnel in arthroscopic ACL reconstruction. This study serves as a proof of concept for the accurate creation of 3D-printed patient-specific guides for the anatomical placement of the femoral tunnel during ACL reconstruction.
[Retrieval and failure analysis of surgical implants in Brazil: the need for proper regulation].
Azevedo, Cesar R de Farias; Hippert, Eduardo
2002-01-01
This paper summarizes several cases of metallurgical failure analysis of surgical implants conducted at the Laboratory of Failure Analysis, Instituto de Pesquisas Tecnológicas (IPT), in Brazil. Failures with two stainless steel femoral compression plates, one stainless steel femoral nail plate, one Ti-6Al-4V alloy maxillary reconstruction plate, and five Nitinol wires were investigated. The results showed that the implants were not in accordance with ISO standards and presented evidence of corrosion-assisted fracture. Furthermore, some of the implants presented manufacturing/processing defects which also contributed to their premature failure. Implantation of materials that are not biocompatible may cause several types of adverse effects in the human body and lead to premature implant failure. A review of prevailing health legislation is needed in Brazil, along with the adoption of regulatory mechanisms to assure the quality of surgical implants on the market, providing for compulsory procedures in the reporting and investigation of surgical implants which have failed in service.
Biomechanical behavior of a cemented ceramic knee replacement under worst case scenarios
NASA Astrophysics Data System (ADS)
Kluess, D.; Mittelmeier, W.; Bader, R.
2009-12-01
In connection with technological advances in the manufacturing of medical ceramics, a newly developed ceramic femoral component was introduced in total knee arthroplasty (TKA). The motivation to consider ceramics in TKA is based on the allergological and tribological benefits as proven in total hip arthroplasty. Owing to the brittleness and reduced fracture toughness of ceramic materials, the biomechanical performance has to be examined intensely. Apart from standard testing, we calculated the implant performance under different worst case scenarios including malposition, bone defects and stumbling. A finite-element-model was developed to calculate the implant performance in situ. The worst case conditions revealed principal stresses 12.6 times higher during stumbling than during normal gait. Nevertheless, none of the calculated principal stress amounts were above the critical strength of the ceramic material used. The analysis of malposition showed the necessity of exact alignment of the implant components.
Biomechanical behavior of a cemented ceramic knee replacement under worst case scenarios
NASA Astrophysics Data System (ADS)
Kluess, D.; Mittelmeier, W.; Bader, R.
2010-03-01
In connection with technological advances in the manufacturing of medical ceramics, a newly developed ceramic femoral component was introduced in total knee arthroplasty (TKA). The motivation to consider ceramics in TKA is based on the allergological and tribological benefits as proven in total hip arthroplasty. Owing to the brittleness and reduced fracture toughness of ceramic materials, the biomechanical performance has to be examined intensely. Apart from standard testing, we calculated the implant performance under different worst case scenarios including malposition, bone defects and stumbling. A finite-element-model was developed to calculate the implant performance in situ. The worst case conditions revealed principal stresses 12.6 times higher during stumbling than during normal gait. Nevertheless, none of the calculated principal stress amounts were above the critical strength of the ceramic material used. The analysis of malposition showed the necessity of exact alignment of the implant components.
A TPMS-based method for modeling porous scaffolds for bionic bone tissue engineering.
Shi, Jianping; Zhu, Liya; Li, Lan; Li, Zongan; Yang, Jiquan; Wang, Xingsong
2018-05-09
In the field of bone defect repair, gradient porous scaffolds have received increased attention because they provide a better environment for promoting tissue regeneration. In this study, we propose an effective method to generate bionic porous scaffolds based on the TPMS (triply periodic minimal surface) and SF (sigmoid function) methods. First, cortical bone morphological features (e.g., pore size and distribution) were determined for several regions of a rabbit femoral bone by analyzing CT-scans. A finite element method was used to evaluate the mechanical properties of the bone at these respective areas. These results were used to place different TPMS substructures into one scaffold domain with smooth transitions. The geometrical parameters of the scaffolds were optimized to match the elastic properties of a human bone. With this proposed method, a functional gradient porous scaffold could be designed and produced by an additive manufacturing method.
Lazik, Andrea; Landgraeber, Stefan; Claßen, Tim; Kraff, Oliver; Lauenstein, Thomas C; Theysohn, Jens M
2015-10-01
To analyze remodeling processes after advanced core decompression (ACD) in patients with avascular femoral head necrosis by means of 3T MRI and to identify indicators for clinical outcome considering the defect size and characteristics of the bone graft and of the neighboring regeneration tissue. Thirty-four hips, with preexisting preoperative MRIs in 21 cases, were examined 1-34 months (mean 12.7) postoperatively by 3T MRI. The volume of necrosis was measured manually pre- and postoperatively to calculate absolute as well as percentage necrosis reduction. The signal intensity of the bone graft was quantified using a 4-point scale. Border phenomena between the bone graft and bone were described and classified into groups. Wilcoxon sign-rank test was used to identify correlations between the analyzed items and clinical signs of femoral head collapse after a mean follow-up time of 28.6 months (10.4-46.8). Mean percentage reduction of necrosis was significantly higher in asymptomatic patients (59.36%) compared to patients with signs of femoral head collapse (28.78%, p = 0.008). Signal intensity of the bone graft increased in T1w and T2w TIRM sequences over time after surgery and was significantly higher in asymptomatic patients. Five border phenomena between the bone graft and healthy bone were identified. Among them, the so-called "rail sign" representing three layers of remodeling tissue correlated with the histological observations. A variety of border phenomena representing remodeling processes have been described using 3T MRI. Beneath the percentage amount of necrosis reduction, we identified the signal intensity of the bone graft as an indicator for clinical outcome.
Influence of bone density on the cement fixation of femoral hip resurfacing components.
Bitsch, Rudi G; Jäger, Sebastian; Lürssen, Marcus; Loidolt, Travis; Schmalzried, Thomas P; Clarius, Michael
2010-08-01
In clinical outcome studies, small component sizes, female gender, femoral shape, focal bone defects, bad bone quality, and biomechanics have been associated with failures of resurfacing arthroplasties. We used a well-established experimental setup and human bone specimens to analyze the effects of bone density on cement fixation of femoral hip resurfacing components. Thirty-one fresh frozen femora were prepared for resurfacing using the original instruments. ASR resurfacing prostheses were implanted after dual-energy X-ray densitometer scans. Real-time measurements of pressure and temperature during implantation, analyses of cement penetration, and measurements of micro motions under torque application were performed. The associations of bone density and measurement data were examined calculating regression lines and multiple correlation coefficients; acceptability was tested with ANOVA. We found significant relations between bone density and micro motion, cement penetration, cement mantle thickness, cement pressure, and interface temperature. Mean bone density of the femora was 0.82 +/- 0.13 g/cm(2), t-score was -0.7 +/- 1.0, and mean micro motion between bone and femoral resurfacing component was 17.5 +/- 9.1 microm/Nm. The regression line between bone density and micro motion was equal to -56.7 x bone density + 63.8, R = 0.815 (p < 0.001). Bone density scans are most helpful for patient selection in hip resurfacing, and a better bone quality leads to higher initial component stability. A sophisticated cementing technique is recommended to avoid vigorous impaction and incomplete seating, since increasing bone density also results in higher cement pressures, lower cement penetration, lower interface temperatures, and thicker cement mantles. Copyright 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Total knee arthroplasty following prior distal femoral fracture.
Papadopoulos, Elias C; Parvizi, Javad; Lai, Choon H; Lewallen, David G
2002-12-01
Femoral fracture may predispose the knee to the development of post-traumatic arthritis by either a direct intra-articular injury or residual limb malalignment. Malunion, intra-articular osseous defects, limb malalignment, retained internal fixation devices, and compromised surrounding soft tissues may in turn affect the outcome of total knee arthroplasty (TKA) in these patients. The aim of our study was to evaluate the result of TKA in patients with previous distal femoral fracture. The results of 48 cemented condylar total knee arthroplasties, performed between 1980 to 1998, in 47 patients with a previous distal femoral fracture were reviewed. There were 37 females and 10 males with an average age of 65 years (range, 19-84 years). Follow-up averaged 6.2 years (range, 2-16 years). No patients were lost to follow-up. At the time of arthroplasty a femoral fracture non-union was present in three knees, all of which were treated with a long stem cemented femoral component and bone grafting. Malunion, defined as angulation greater than 10 degrees in the coronal plain or greater than 15 degrees in the sagittal plain, was present in 21 knees. Of these, six underwent distal femoral osteotomy during TKA. In the remaining 15 patients, with a malunion, the deformity was addressed by alterations in the orientation and location of bone resection. Other procedures were commonly needed at the time of arthroplasty and included: lateral retinacular release (22 knees), extensor mechanism realignment (eight knees), and collateral ligament reconstruction (two knees). The mean pre-operative Knee Society Scores were 40 (range, 0-80) for pain and 48 (range, 0-100) for function and improved significantly to a mean of 84 (range, 37-99) and 66 (range, 0-100) points, respectively, at the latest follow-up (P<0.001). The knee arc of motion improved from a pre-operative mean of 83-99 degrees at the latest follow-up (P<0.004). Post-operative manipulation under anesthesia for poor motion was carried out in four knees. Two knees had aseptic loosening that required subsequent revisions. Three knees developed deep infection which was treated with debridement and retention of components in one knee, arthrodesis in another, and eventual amputation in one knee. Significant improvement in function and relief of pain is seen in the vast majority of patients with previous distal femoral fractures undergoing subsequent TKA. However, these patients are at increased risk for restricted motion and perioperative complications following TKA. Special efforts to preserve the vascularity of the skin and subcutaneous tissues, restore limb alignment, ensure correct component positioning, and achieve soft tissue balance may help minimize the problems identified in this study.
USE OF BIOCERAMICS IN FILLING BONE DEFECTS
Garrido, Carlos Antõnio; Sampaio, Tania Clarete Fonseca Vieira Sales
2015-01-01
Objective: To present the results from using biological ceramics for filling bone defects resulting from post-traumatic or orthopedic injuries. Methods: Thirty-six patients with bone defects caused by trauma or orthopedic injury were evaluated. Nineteen patients were male (52.8%) and 17 were female (47.2%). Their ages ranged from 19 to 84 years, with a mean of 45.7 years and median of 37 years. Only patients with defects that required at least five grams of biological ceramic were included. Eighteen cases were classified as orthopedic: bone defects were observed in 11 cases of total hip arthroplasty; one case of primary total hip arthroplasty, due to coxarthrosis; five cases of femoral or tibial open wedge osteotomy; and one case of tarsal arthrodesis. There were 18 cases of trauma-related defects; uninfected pseudarthrosis, eight cases; recent fractures of the tibial plateau with compression of the spongy bone, three cases; and exposed fractures treated with external fixators, seven cases. The surgical technique consisted of curetting and debriding the injury until bone suitable for grafting was found. Biological ceramic was then used to fill the defect and some kind of fixation was applied. Results: Among the 36 patients evaluated, it was seen that 35 (97.2%) presented integration of the biological ceramic, while one case of open fracture treated with external fixation had poor integration of the biological ceramic. Conclusion: Treatment of bone defects of orthopedic or post-traumatic etiology using a phosphocalcium ceramic composed of hydroxyapatite was shown to be a practical, effective and safe method. PMID:27022576
Osteogenic efficacy of strontium hydroxyapatite micro-granules in osteoporotic rat model.
Chandran, Sunitha; Babu S, Suresh; Vs, Hari Krishnan; Varma, H K; John, Annie
2016-10-01
Excessive demineralization in osteoporotic bones impairs its self-regeneration potential following a defect/fracture and is of great concern among the aged population. In this context, implants with inherent osteogenic ability loaded with therapeutic ions like Strontium (Sr 2+ ) may bring forth promising outcomes. Micro-granular Strontium incorporated Hydroxyapatite scaffolds have been synthesized and in vivo osteogenic efficacy was evaluated in a long-term osteoporosis-induced aged (LOA) rat model. Micro-granules with improved surface area are anticipated to resorb faster and together with the inherent bioactive properties of Hydroxyapatite with the leaching of Strontium ions from the scaffold, osteoporotic bone healing may be promoted. Long-term osteoporosis-induced aged rat model was chosen to extrapolate the results to clinical osteoporotic condition in the aged. Micro-granular 10% Strontium incorporated Hydroxyapatite synthesized by wet precipitation method exhibited increased in vitro dissolution rate and inductively coupled plasma studies confirmed Strontium ion release of 0.01 mM, proving its therapeutic potential for osteoporotic applications. Wistar rats were induced to long-term osteoporosis-induced aged model by ovariectomy along with a prolonged induction period of 10 months. Thereafter, osteogenic efficacy of Strontium incorporated Hydroxyapatite micro-granules was evaluated in femoral bone defects in the long-term osteoporosis-induced aged model. Post eight weeks of implantation in vivo regeneration efficacy ratio was highest in the Strontium incorporated Hydroxyapatite implanted group (0.92 ± 0.04) compared to sham and Hydroxyapatite implanted group. Micro CT evaluation further substantiated the improved osteointegration of Strontium incorporated Hydroxyapatite implants from the density histograms. Thus, the therapeutical potential of micro-granular Strontium incorporated Hydroxyapatite scaffolds becomes relevant, especially as bone void fillers in osteoporotic cases of tumor resection or trauma. © The Author(s) 2016.
NASA Technical Reports Server (NTRS)
Arbeille, P.; Berson, M.; Blondeau, B.; Durand, A.; Bodard, S.; Locatelli, A.; Fox, G. E. (Principal Investigator)
1995-01-01
The object of this study was to define and validate a non-invasive method of evaluation and monitoring of vascular resistances in the leg. Blood flow velocity was measured by Doppler ultrasound in an animal model (ewe) with similar blood flow characteristics in the lower limb as man and allowing access to the required invasive measurements for validation of the method (pressure and flow). Vascular resistances distal to the measuring point (femoral, for example) were assessed using the resistance index R = D/S, S being the peak systolic deflection and D that of diastolic reflux of the Doppler spectral analysis of flow in the femoral artery. The values and variations of this resistance index were compared with the vascular resistances calculated from measurements of pressure and flow at the point of Doppler sampling and expressed in mmHg/ml/min. Femoral flow was measured by Doppler ultrasound (Doppler-echo), and mean pressure by an arterial catheter introduced into the abdominal aorta. Compression of the lower limb veins induced a venous return resulting in a reduction of cardiac output and femoral flow. During compression, femoral flow decreased by an average of 29% (p < 0.001) although mean pressure and heart rate did not change significantly. The femoral resistance index (Rf) increased by an average of 37.5% (p < 0.01) and vascular resistances increased by 45.9% (p < 0.01). Injection of 1 mg adrenaline induced peripheral vasoconstriction with an increase in blood pressure and a decrease in heart rate and femoral flow.(ABSTRACT TRUNCATED AT 250 WORDS).
Designing an Optimized Novel Femoral Stem
Babaniamansour, Parto; Ebrahimian-Hosseinabadi, Mehdi; Zargar-Kharazi, Anousheh
2017-01-01
Background: After total hip arthroplasty, there would be some problems for the patients. Implant loosening is one of the significant problems which results in thigh pain and even revision surgery. Difference between Young's modulus of bone-metal is the cause of stress shielding, atrophy, and subsequent implant loosening. Materials and Methods: In this paper, femoral stem stiffness is reduced by novel biomechanical and biomaterial design which includes using proper design parameters, coating it with porous surface, and modeling the sketch by the software. Parametric design of femoral stem is done on the basis of clinical reports. Results: Optimized model for femoral stem is proposed. Curved tapered stem with trapezoidal cross-section and particular neck and offset is designed. Fully porous surface is suggested. Moreover, Designed femoral stem analysis showed the Ti6Al4V stem which is covered with layer of 1.5 mm in thickness and 50% of porosity is as stiff as 77 GPa that is 30% less than the stem without any porosity. Porous surface of designed stem makes it fix biologically; thus, prosthesis loosening probability decreases. Conclusion: By optimizing femoral stem geometry (size and shape) and also making a porous surface, which had an intermediate stiffness of bone and implant, a more efficient hip joint prosthesis with more durability fixation was achieved due to better stress transmission from implant to the bone. PMID:28840118
Mathijssen, N M C; Sturm, P D; Pilot, P; Bloem, R M; Buma, P; Petit, P L; Schreurs, B W
2013-12-01
With bone impaction grafting, cancellous bone chips made from allograft femoral heads are impacted in a bone defect, which introduces an additional source of infection. The potential benefit of the use of pre-processed bone chips was investigated by comparing the bacterial contamination of bone chips prepared intraoperatively with the bacterial contamination of pre-processed bone chips at different stages in the surgical procedure. To investigate baseline contamination of the bone grafts, specimens were collected during 88 procedures before actual use or preparation of the bone chips: in 44 procedures intraoperatively prepared chips were used (Group A) and in the other 44 procedures pre-processed bone chips were used (Group B). In 64 of these procedures (32 using locally prepared bone chips and 32 using pre-processed bone chips) specimens were also collected later in the procedure to investigate contamination after use and preparation of the bone chips. In total, 8 procedures had one or more positive specimen(s) (12.5 %). Contamination rates were not significantly different between bone chips prepared at the operating theatre and pre-processed bone chips. In conclusion, there was no difference in bacterial contamination between bone chips prepared from whole femoral heads in the operating room and pre-processed bone chips, and therefore, both types of bone allografts are comparable with respect to risk of infection.
Yue, Yong; Yao, Yong-jie; Xie, Xiao-ping; Wang, Bing; Zhu, Qing-sheng; Wu, Xing-yu
2002-12-01
Objective. To observe the changes of pressure-volume relationships of rabbit femoral veins and their structural changes caused by simulated weightlessness. Method. Head-Down Tilt (HDT) -20 degrees rabbit model was used to simulate weightlessness. Twenty four healthy male New Zealand Rabbits were randomly divided into 21 d HDT group,10 d HDT group and control group, (8 in each group). Pressure-volume (P-V) relationship of rabbits femoral veins was measured and the microstructure of the veins was observed. Result. The femoral vein P-V relationship curves of HDT groups showed a larger volume change ratio than that of control group. This change was that 21 d HDT group was even more obvious than that of HDT-10 d group. B1 and B2 in quadratic equations of 21 d HDT group were significantly higher than the values of both 10 d HDT group and control group during expansion (inflow) and collapse (outflow) (P<0.01). The result of histological examination showed that the contents and structure of femoral vein wall of HDT-rabbits changed significantly. Endothelial cells of femoral vein became short and columnar or cubic, some of which fell off. Smooth muscle layer became thinner. Conclusion. Femoral venous compliance increased after weightlessness-simulation and the femoral venous compliance in 21 d-HDT rabbits increased more obviously than that in 10 d-HDT rabbits. The structure of femoral vein wall had changed obviously.
A Mutation in the Dmp1 Gene Alters Phosphate Responsiveness in Mice
Gerard-O'Riley, Rita L.; Acton, Dena; McQueen, Amie K.; Strobel, Isabel E.; Witcher, Phillip C.; Feng, Jian Q.; Econs, Michael J.
2017-01-01
Mutations in the dentin matrix protein 1 (DMP1) gene cause autosomal recessive hypophosphatemic rickets (ARHR). Hypophosphatemia in ARHR results from increased circulating levels of the phosphaturic hormone, fibroblast growth factor 23 (FGF23). Similarly, elevated FGF23, caused by mutations in the PHEX gene, is responsible for the hypophosphatemia in X-linked hypophosphatemic rickets (XLH). Previously, we demonstrated that a Phex mutation in mice creates a lower set point for extracellular phosphate, where an increment in phosphorus further stimulates Fgf23 production to maintain low serum phosphorus levels. To test the presence of the similar set point defect in ARHR, we generated 4- and 12-week-old Dmp1/Galnt3 double knockout mice and controls, including Dmp1 knockout mice (a murine model of ARHR), Galnt3 knockout mice (a murine model of familial tumoral calcinosis), and phenotypically normal double heterozygous mice. Galnt3 knockout mice had increased proteolytic cleavage of Fgf23, leading to low circulating intact Fgf23 levels with consequent hyperphosphatemia. In contrast, Dmp1 knockout mice had little Fgf23 cleavage and increased femoral Fgf23 expression, resulting in hypophosphatemia and low femoral bone mineral density (BMD). However, introduction of the Galnt3 null allele to Dmp1 knockout mice resulted in a significant increase in serum phosphorus and normalization of BMD. This increased serum phosphorus was accompanied by markedly elevated Fgf23 expression and circulating Fgf23 levels, an attempt to reduce serum phosphorus in the face of improving phosphorus levels. These data indicate that a Dmp1 mutation creates a lower set point for extracellular phosphate and maintains it through the regulation of Fgf23 cleavage and expression. PMID:28005411
A Mutation in the Dmp1 Gene Alters Phosphate Responsiveness in Mice.
Ichikawa, Shoji; Gerard-O'Riley, Rita L; Acton, Dena; McQueen, Amie K; Strobel, Isabel E; Witcher, Phillip C; Feng, Jian Q; Econs, Michael J
2017-03-01
Mutations in the dentin matrix protein 1 (DMP1) gene cause autosomal recessive hypophosphatemic rickets (ARHR). Hypophosphatemia in ARHR results from increased circulating levels of the phosphaturic hormone, fibroblast growth factor 23 (FGF23). Similarly, elevated FGF23, caused by mutations in the PHEX gene, is responsible for the hypophosphatemia in X-linked hypophosphatemic rickets (XLH). Previously, we demonstrated that a Phex mutation in mice creates a lower set point for extracellular phosphate, where an increment in phosphorus further stimulates Fgf23 production to maintain low serum phosphorus levels. To test the presence of the similar set point defect in ARHR, we generated 4- and 12-week-old Dmp1/Galnt3 double knockout mice and controls, including Dmp1 knockout mice (a murine model of ARHR), Galnt3 knockout mice (a murine model of familial tumoral calcinosis), and phenotypically normal double heterozygous mice. Galnt3 knockout mice had increased proteolytic cleavage of Fgf23, leading to low circulating intact Fgf23 levels with consequent hyperphosphatemia. In contrast, Dmp1 knockout mice had little Fgf23 cleavage and increased femoral Fgf23 expression, resulting in hypophosphatemia and low femoral bone mineral density (BMD). However, introduction of the Galnt3 null allele to Dmp1 knockout mice resulted in a significant increase in serum phosphorus and normalization of BMD. This increased serum phosphorus was accompanied by markedly elevated Fgf23 expression and circulating Fgf23 levels, an attempt to reduce serum phosphorus in the face of improving phosphorus levels. These data indicate that a Dmp1 mutation creates a lower set point for extracellular phosphate and maintains it through the regulation of Fgf23 cleavage and expression. Copyright © 2017 by the Endocrine Society.
Measuring Femoral Torsion In Vivo Using Freehand 3-D Ultrasound Imaging.
Passmore, Elyse; Pandy, Marcus G; Graham, H Kerr; Sangeux, Morgan
2016-02-01
Despite variation in bone geometry, muscle and joint function is often investigated using generic musculoskeletal models. Patient-specific bone geometry can be obtained from computerised tomography, which involves ionising radiation, or magnetic resonance imaging (MRI), which is costly and time consuming. Freehand 3-D ultrasound provides an alternative to obtain bony geometry. The purpose of this study was to determine the accuracy and repeatability of 3-D ultrasound in measuring femoral torsion. Measurements of femoral torsion were performed on 10 healthy adults using MRI and 3-D ultrasound. Measurements of femoral torsion from 3-D ultrasound were, on average, smaller than those from MRI (mean difference = 1.8°; 95% confidence interval: -3.9°, 7.5°). MRI and 3-D ultrasound had Bland and Altman repeatability coefficients of 3.1° and 3.7°, respectively. Accurate measurements of femoral torsion were obtained with 3-D ultrasound offering the potential to acquire patient-specific bone geometry for musculoskeletal modelling. Three-dimensional ultrasound is non-invasive and relatively inexpensive and can be integrated into gait analysis. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Kang, K-T.; Koh, Y-G.; Son, J.; Kwon, O-R.; Baek, C.; Jung, S. H.
2016-01-01
Objectives Malrotation of the femoral component can result in post-operative complications in total knee arthroplasty (TKA), including patellar maltracking. Therefore, we used computational simulation to investigate the influence of femoral malrotation on contact stresses on the polyethylene (PE) insert and on the patellar button as well as on the forces on the collateral ligaments. Materials and Methods Validated finite element (FE) models, for internal and external malrotations from 0° to 10° with regard to the neutral position, were developed to evaluate the effect of malrotation on the femoral component in TKA. Femoral malrotation in TKA on the knee joint was simulated in walking stance-phase gait and squat loading conditions. Results Contact stress on the medial side of the PE insert increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. There was an opposite trend in the lateral side of the PE insert case. Contact stress on the patellar button increased with internal femoral malrotation and decreased with external femoral malrotation in both stance-phase gait and squat loading conditions. In particular, contact stress on the patellar button increased by 98% with internal malrotation of 10° in the squat loading condition. The force on the medial collateral ligament (MCL) and the lateral collateral ligament (LCL) increased with internal and external femoral malrotations, respectively. Conclusions These findings provide support for orthopaedic surgeons to determine a more accurate femoral component alignment in order to reduce post-operative PE problems. Cite this article: K-T. Kang, Y-G. Koh, J. Son, O-R. Kwon, C. Baek, S. H. Jung, K. K. Park. Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation. Bone Joint Res 2016;5:552–559. DOI: 10.1302/2046-3758.511.BJR-2016-0107.R1. PMID:28094763
Finite element modelling of primary hip stem stability: the effect of interference fit.
Abdul-Kadir, Mohammed Rafiq; Hansen, Ulrich; Klabunde, Ralf; Lucas, Duncan; Amis, Andrew
2008-01-01
The most commonly reported complications related to cementless hip stems are loosening and thigh pain; both of these have been attributed to high levels of relative micromotion at the bone-implant interface due to insufficient primary fixation. Primary fixation is believed by many to rely on achieving a sufficient interference fit between the implant and the bone. However, attempting to achieve a high interference fit not infrequently leads to femoral canal fracture either intra-operatively or soon after. The appropriate range of diametrical interference fit that ensures primary stability without risking femoral fracture is not well understood. In this study, a finite element model was constructed to predict micromotion and, therefore, instability of femoral stems. The model was correlated with an in vitro micromotion experiment carried out on four cadaver femurs. It was confirmed that interference fit has a very significant effect on micromotion and ignoring this parameter in an analysis of primary stability is likely to underestimate the stability of the stem. Furthermore, it was predicted that the optimal level of interference fit is around 50 microm as this is sufficient to achieve good primary fixation while having a safety factor of 2 against femoral canal fracture. This result is of clinical relevance as it indicates a recommendation for the surgeon to err on the side of a low interference fit rather than risking femoral fracture.
Knobloch, K; Herold, C; Vogt, P M
2012-04-01
Sustainable and durable soft tissue coverage at the lower extremity following trauma, tumor resections, sequelae of radiation therapy or osteomyelitis using free latissimus dorsi muscle transfer is provided by a free latissimus dorsi muscle flap. Soft tissue defects at the lower extremity following trauma, tumor resections, and sequelae of radiation therapy or osteomyelitis. Thoracotomy with incision of the latissimus dorsi muscle; a relative contraindication in wheelchair drivers as well as in overhead athletes due to potential diminished strength and shoulder proprioception following latissimus dorsi muscle transplantation. Under general anesthesia the patient is positioned laterally, and a substantial and meticulous debridement of the defect is performed, as is the identification and preparation of the target vessel, which is preferentially the posterior tibial artery at the calf, or more proximally the popliteal or femoral artery from the medial side as well as concomitant veins/the great saphenous vein. A tailored latissimus dorsi musculocutaneous flap is harvested with subsequent microsurgical anastomosis to the target vessel with preferential end-to-side anastomosis of the artery and end-to-end anastomosis of one or two veins. A 24-h intermediate care unit, clinical flap monitoring for at least 5-7 days, dangling of the flap using an elastic bandage for an initial 3 times 5 min starting on POD 7, compression stockings for at least 6 months subsequently. From 2001-2007 75 free latissimus dorsi flaps were performed (53 ± 17 years) for soft tissue coverage at the lower extremity. In 58% the target vessel was the posterior tibial artery, in 11% the femoral artery, in 8% the anterior tibial artery and in 8% the popliteal artery. In 15% an arteriovenous (AV) loop was applied. Overall free flap survival was 95%. We encountered four total flap losses, exclusively in complex reconstructions with AV-loop situations.
Hanke, M; Djonov, V; Tannast, M; Keel, M J; Bastian, J D
2016-06-01
Medial penetration of the helical blade into the hip joint after fixation of trochanteric fractures using the proximal femur nail antirotation (PFN-A) is a potential failure mode. In low demand patients a blade exchange with cement augmentation may be an option if conversion to total hip arthroplasty is unfeasible to salvage the cut-through. This article describes a technique to avoid intraarticular cement leakage using a cement plug to close the defect in the femoral head caused by the cut-through.
Santoni, Brandon G; Nayak, Aniruddh N; Cooper, Seth A; Smithson, Ian R; Cox, Jacob L; Marberry, Scott T; Sanders, Roy W
2016-04-01
This study compared the stabilizing effect of 2 intertrochanteric (IT) fracture fixation devices in a cadaveric hemi-pelvis biomechanical model. Eleven pairs of cadaveric osteopenic female hemi-pelves with intact hip joint and capsular ligaments were used. An unstable IT fracture (OTA 31-A2) was created in each specimen and stabilized with a single lag screw device (Gamma 3) or an integrated dual screw (IDS) device (InterTAN). The hemi-pelves were inverted, coupled to a biaxial apparatus and subjected to 13.5 k cycles of loading (3 months) using controlled, oscillating pelvic rotation (0-90 degrees) plus cyclic axial femoral loading at a 2:1 body weight (BW) ratio. Femoral head rotation and varus collapse were monitored optoelectonically. For specimens surviving 3 months of loading, additional loading was performed in 0.25 × BW/250 cycle increments to a maximum of 4 × BW or failure. Femoral head rotation with IDS fixation was significantly less than the single lag screw construct after 3 months of simulated loading (P = 0.016). Maximum femoral head rotation at the end of 4 × BW loading was 7× less for the IDS construct (P = 0.006). Varus collapse was significantly less with the IDS construct over the entire loading cycle (P = 0.021). In this worst-case model of an osteopenic, unstable, IT fracture, the IDS construct, likely owing to its larger surface area, noncylindrical profile, and fracture compression, provided significantly greater stability and resistance to femoral head rotation and varus collapse.
Beaulieu, Mélanie L.; Wojtys, Edward M.; Ashton-Miller, James A.
2015-01-01
Background A reduced range of hip internal rotation is associated with increased peak anterior cruciate ligament (ACL) strain and risk for injury. It is unknown, however, whether limiting the available range of internal femoral rotation increases the susceptibility of the ACL to fatigue failure. Hypothesis Risk of ACL failure is significantly greater in female knee specimens with a limited range of internal femoral rotation, smaller femoral-ACL attachment angle, and smaller tibial eminence volume during repeated in vitro simulated single-leg pivot landings. Study Design Controlled laboratory study. Methods A custom-built testing apparatus was used to simulate repeated single-leg pivot landings with a 4×-body weight impulsive load that induces knee compression, knee flexion, and internal tibial torque in 32 paired human knee specimens from 8 male and 8 female donors. These test loads were applied to each pair of specimens, in one knee with limited internal femoral rotation and in the contralateral knee with femoral rotation resisted by 2 springs to simulate the active hip rotator muscles’ resistance to stretch. The landings were repeated until ACL failure occurred or until a minimum of 100 trials were executed. The angle at which the ACL originates from the femur and the tibial eminence volume were measured on magnetic resonance images. Results The final Cox regression model (P = .024) revealed that range of internal femoral rotation and sex of donor were significant factors in determining risk of ACL fatigue failure. The specimens with limited range of internal femoral rotation had a failure risk 17.1 times higher than did the specimens with free rotation (P = .016). The female knee specimens had a risk of ACL failure 26.9 times higher than the male specimens (P = .055). Conclusion Limiting the range of internal femoral rotation during repetitive pivot landings increases the risk of an ACL fatigue failure in comparison with free rotation in a cadaveric model. Clinical Relevance Screening for restricted internal rotation at the hip in ACL injury prevention programs as well as in individuals with ACL injuries and/or reconstructions is warranted. PMID:26122384
Beaulieu, Mélanie L; Wojtys, Edward M; Ashton-Miller, James A
2015-09-01
A reduced range of hip internal rotation is associated with increased peak anterior cruciate ligament (ACL) strain and risk for injury. It is unknown, however, whether limiting the available range of internal femoral rotation increases the susceptibility of the ACL to fatigue failure. Risk of ACL failure is significantly greater in female knee specimens with a limited range of internal femoral rotation, smaller femoral-ACL attachment angle, and smaller tibial eminence volume during repeated in vitro simulated single-leg pivot landings. Controlled laboratory study. A custom-built testing apparatus was used to simulate repeated single-leg pivot landings with a 4×-body weight impulsive load that induces knee compression, knee flexion, and internal tibial torque in 32 paired human knee specimens from 8 male and 8 female donors. These test loads were applied to each pair of specimens, in one knee with limited internal femoral rotation and in the contralateral knee with femoral rotation resisted by 2 springs to simulate the active hip rotator muscles' resistance to stretch. The landings were repeated until ACL failure occurred or until a minimum of 100 trials were executed. The angle at which the ACL originates from the femur and the tibial eminence volume were measured on magnetic resonance images. The final Cox regression model (P = .024) revealed that range of internal femoral rotation and sex of donor were significant factors in determining risk of ACL fatigue failure. The specimens with limited range of internal femoral rotation had a failure risk 17.1 times higher than did the specimens with free rotation (P = .016). The female knee specimens had a risk of ACL failure 26.9 times higher than the male specimens (P = .055). Limiting the range of internal femoral rotation during repetitive pivot landings increases the risk of an ACL fatigue failure in comparison with free rotation in a cadaveric model. Screening for restricted internal rotation at the hip in ACL injury prevention programs as well as in individuals with ACL injuries and/or reconstructions is warranted. © 2015 The Author(s).
Kuriyama, Shinichi; Ishikawa, Masahiro; Nakamura, Shinichiro; Furu, Moritoshi; Ito, Hiromu; Matsuda, Shuichi
2016-08-01
Condylar lift-off can induce excessive polyethylene wear after total knee arthroplasty (TKA). A computer simulation was used to evaluate the influence of femoral varus alignment and lateral collateral ligament (LCL) laxity on lift-off after single-design TKA. It was hypothesised that proper ligament balancing and coronal alignment would prevent lift-off. The computer model in this study is a dynamic musculoskeletal program that simulates gait up to 60° of knee flexion. The lift-off phenomenon was defined as positive with an intercomponent distance of >2 mm. In neutrally aligned components in the coronal plane, the femoral and tibial components were set perpendicular to the femoral and tibial mechanical axis, respectively. The femoral coronal alignment was changed from neutral to 5° varus in 1° increments. Simultaneously, the LCL length was elongated from 0 to 5 mm in 1-mm increments to provide a model of pathological slack. Within 2° of femoral varus alignment, lift-off did not occur even if the LCL was elongated by up to 5 mm. However, lift-off occurred easily in the stance phase in femoral varus alignments of >3° with slight LCL slack. The contact forces of the tibiofemoral joint were influenced more by femoral varus alignment than by LCL laxity. Aiming for neutral alignment in severely varus knees makes it difficult to achieve appropriate ligament balance. Our study suggests that no lift-off occurs with excessive LCL laxity alone in a neutrally aligned TKA and therefore that varus alignment should be avoided to decrease lift-off after TKA. Case series, Level IV.
Jungmann, P.M.; Kraus, M.S.; Nardo, L.; Liebl, H.; Alizai, H.; Joseph, G.B.; Liu, F.; Lynch, J.; McCulloch, C.E.; Nevitt, M.C.; Link, T.M.
2014-01-01
Purpose To study the natural evolution of cartilage T2 relaxation times in knees with various extents of morphological cartilage abnormalities, assessed with 3T MRI from the Osteoarthritis Initiative. Materials and Methods Right knee MRIs of 245, 45–60 year old individuals without radiographic OA were included. Cartilage was segmented and T2 maps were generated in five compartments (patella, medial and lateral femoral condyle, medial and lateral tibia) at baseline and two-year follow-up. We examined the association of T2 values and two-year change of T2 values with various Whole-Organ MR Imaging Scores (WORMS). Statistical analysis was performed with ANOVA and Students t-tests. Results Higher baseline T2 was associated with more severe cartilage defects at baseline and subsequent cartilage loss (P<0.001). However, longitudinal T2 change was inversely associated with both baseline (P=0.038) and follow-up (P=0.002) severity of cartilage defects. Knees that developed new cartilage defects had smaller increases in T2 than subjects without defects (P=0.045). Individuals with higher baseline T2 showed smaller T2 increases over time (P<0.001). Conclusion An inverse correlation of longitudinal T2 changes versus baseline T2 values and morphological cartilage abnormalities suggests that once morphological cartilage defects occur, T2 values may be limited for evaluating further cartilage degradation. PMID:24038491
Munirah, S; Samsudin, O C; Chen, H C; Salmah, S H Sharifah; Aminuddin, B S; Ruszymah, B H I
2008-07-01
Chondrocytes were isolated from articular cartilage biopsy and were cultivated in vitro. Approximately 30 million of cultured chondrocytes per ml were incorporated with autologous plasma-derived fibrin to form three-dimensional construct. Full-thickness punch hole defects were created in lateral and medial femoral condyles. The defects were implanted either with the autologous 'chondrocytes-fibrin' construct (ACFC), autologous chondrocytes (ACI) or fibrin blank (AF). Sheep were euthanized after 12 weeks. The gross morphology of all defects treated with ACFC implantation, ACI and AF exhibited median scores which correspond to a nearly normal appearance according to the International Cartilage Repair Society (ICRS) classification. ACFC significantly enhanced cartilage repair compared to ACI and AF in accordance with the modified O'Driscoll histological scoring scale. The relative sulphated glycosaminoglycans content (%) was significantly higher (p < 0.05) in ACFC when compared to control groups; ACI vs. fibrin only vs. untreated (blank). Results showed that ACFC implantation exhibited superior cartilage-like tissue regeneration compared to ACI. If the result is applicable to the human, it possibly will improve the existing treatment approaches for cartilage restoration in orthopaedic surgery.
Yu, Weilin; Sun, Tuan-Wei; Qi, Chao; Ding, Zhenyu; Zhao, Huakun; Zhao, Shichang; Shi, Zhongmin; Zhu, Ying-Jie; Chen, Daoyun; He, Yaohua
2017-01-01
Biomaterials with high osteogenic activity are desirable for sufficient healing of bone defects resulting from trauma, tumor, infection, and congenital abnormalities. Synthetic materials mimicking the structure and composition of human trabecular bone are of considerable potential in bone augmentation. In the present study, a zinc (Zn)-doped mesoporous hydroxyapatite microspheres (Zn-MHMs)/collagen scaffold (Zn-MHMs/Coll) was developed through a lyophilization fabrication process and designed to mimic the trabecular bone. The Zn-MHMs were synthesized through a microwave-hydrothermal method by using creatine phosphate as an organic phosphorus source. Zn-MHMs that consist of hydroxyapatite nanosheets showed relatively uniform spherical morphology, mesoporous hollow structure, high specific surface area, and homogeneous Zn distribution. They were additionally investigated as a drug nanocarrier, which was efficient in drug delivery and presented a pH-responsive drug release behavior. Furthermore, they were incorporated into the collagen matrix to construct a biomimetic scaffold optimized for bone tissue regeneration. The Zn-MHMs/Coll scaffolds showed an interconnected pore structure in the range of 100–300 μm and a sustained release of Zn ions. More importantly, the Zn-MHMs/Coll scaffolds could enhance the osteogenic differentiation of rat bone marrow-derived mesenchymal stem cells. Finally, the bone defect repair results of critical-sized femoral condyle defect rat model demonstrated that the Zn-MHMs/Coll scaffolds could enhance bone regeneration compared with the Coll or MHMs/Coll scaffolds. The results suggest that the biomimetic Zn-MHMs/Coll scaffolds may be of enormous potential in bone repair and regeneration. PMID:28392688
Yu, Weilin; Sun, Tuan-Wei; Qi, Chao; Ding, Zhenyu; Zhao, Huakun; Zhao, Shichang; Shi, Zhongmin; Zhu, Ying-Jie; Chen, Daoyun; He, Yaohua
2017-01-01
Biomaterials with high osteogenic activity are desirable for sufficient healing of bone defects resulting from trauma, tumor, infection, and congenital abnormalities. Synthetic materials mimicking the structure and composition of human trabecular bone are of considerable potential in bone augmentation. In the present study, a zinc (Zn)-doped mesoporous hydroxyapatite microspheres (Zn-MHMs)/collagen scaffold (Zn-MHMs/Coll) was developed through a lyophilization fabrication process and designed to mimic the trabecular bone. The Zn-MHMs were synthesized through a microwave-hydrothermal method by using creatine phosphate as an organic phosphorus source. Zn-MHMs that consist of hydroxyapatite nanosheets showed relatively uniform spherical morphology, mesoporous hollow structure, high specific surface area, and homogeneous Zn distribution. They were additionally investigated as a drug nanocarrier, which was efficient in drug delivery and presented a pH-responsive drug release behavior. Furthermore, they were incorporated into the collagen matrix to construct a biomimetic scaffold optimized for bone tissue regeneration. The Zn-MHMs/Coll scaffolds showed an interconnected pore structure in the range of 100-300 μm and a sustained release of Zn ions. More importantly, the Zn-MHMs/Coll scaffolds could enhance the osteogenic differentiation of rat bone marrow-derived mesenchymal stem cells. Finally, the bone defect repair results of critical-sized femoral condyle defect rat model demonstrated that the Zn-MHMs/Coll scaffolds could enhance bone regeneration compared with the Coll or MHMs/Coll scaffolds. The results suggest that the biomimetic Zn-MHMs/Coll scaffolds may be of enormous potential in bone repair and regeneration.
Westberry, David E; Wack, Linda I; Davis, Roy B; Hardin, James W
2018-05-01
Multiple measurement methods are available to assess transverse plane alignment of the lower extremity. This study was performed to determine the extent of correlation between femoral anteversion assessment using simultaneous biplanar radiographs and three-dimensional modeling (EOS imaging), clinical hip rotation by physical examination, and dynamic hip rotation assessed by gait analysis. Seventy-seven patients with cerebral palsy (GMFCS Level I and II) and 33 neurologically typical children with torsional abnormalities completed a comprehensive gait analysis with same day biplanar anterior-posterior and lateral radiographs and three-dimensional transverse plane assessment of femoral anteversion. Correlations were determined between physical exam of hip rotation, EOS imaging of femoral anteversion, and transverse plane hip kinematics for this retrospective review study. Linear regression analysis revealed a weak relationship between physical examination measures of hip rotation and biplanar radiographic assessment of femoral anteversion. Similarly, poor correlation was found between clinical evaluation of femoral anteversion and motion assessment of dynamic hip rotation. Correlations were better in neurologically typical children with torsional abnormalities compared to children with gait dysfunction secondary to cerebral palsy. Dynamic hip rotation cannot be predicted by physical examination measures of hip range of motion or from three-dimensional assessment of femoral anteversion derived from biplanar radiographs. Copyright © 2018 Elsevier B.V. All rights reserved.
Pithioux, Martine; Roseren, Flavy; Jalain, Christian; Launay, Franck; Charpiot, Philippe; Chabrand, Patrick; Roffino, Sandrine; Lamy, Edouard
2017-10-23
This protocol describes the use of a newly developed external fixator for distraction osteogenesis in a rat femoral model. Distraction osteogenesis (DO) is a surgical technique leading to bone regeneration after an osteotomy. The osteotomized extremities are moved away from each other by gradual distraction to reach the desired elongation. This procedure is widely used in humans for lower and upper limb lengthening, treatment after a bone nonunion, or the regeneration of a bone defect following surgery for bone tumor excision, as well as in maxillofacial reconstruction. Only a few studies clearly demonstrate the efficiency of their protocol in obtaining a functional regenerated bone, i.e., bone that will support physiological weight-bearing without fracture after removal of the external fixator. Moreover, protocols for DO vary and reproducibility is limited by lack of information, making comparison between studies difficult. The aim of this study was to develop a reproducible protocol comprising an appropriate external fixator design for rat limb lengthening, with a detailed surgical technique that permits physiological weight-bearing by the animal after removal of the external fixator.
Bone mineral density of the femoral neck in resurfacing hip arthroplasty
Ovesen, Ole; Brixen, Kim; Varmarken, Jens-Erik; Overgaard, SØren
2010-01-01
Background and purpose Resurfacing total hip arthroplasty (RTHA) may preserve the femoral neck bone stock postoperatively. Bone mineral density (BMD) may be affected by the hip position, which might bias longitudinal studies. We investigated the dependency of BMD precision on type of ROI and hip position. Method We DXA-scanned the femoral neck of 15 resurfacing patients twice with the hip in 3 different rotations: 15° internal, neutral, and 15° external. For each position, BMD was analyzed with 3 surface area models. One model measured BMD in the total femoral neck, the second model divided the neck in two, and the third model had 6 divisions. Results When all hip positions were pooled, average coefficients of variation (CVs) of 3.1%, 3.6%, and 4.6% were found in the 1-, 2-, and 6-region models, respectively. The externally rotated hip position was less reproducible. When rotating in increments of 15° or 30°, the average CVs rose to 7.2%, 7.3%, and 12% in the 3 models. Rotation affected the precision most in the model that divided the neck in 6 subregions, predominantly in the lateral and distal regions. For larger-region models, some rotation could be allowed without compromising the precision. Interpretation If hip rotation is strictly controlled, DXA can reliably provide detailed topographical information about the BMD changes around an RTHA. As rotation strongly affects the precision of the BMD measurements in small regions, we suggest that a less detailed model should be used for analysis in studies where the leg position has not been firmly controlled. PMID:20367420
Miles, Brad; Kolos, Elizabeth; Walter, William L; Appleyard, Richard; Shi, Angela; Li, Qing; Ruys, Andrew J
2015-06-01
Subject-specific finite element (FE) modeling methodology could predict peri-prosthetic femoral fracture (PFF) for cementless hip arthoplasty in the early postoperative period. This study develops methodology for subject-specific finite element modeling by using the element deactivation technique to simulate bone failure and validate with experimental testing, thereby predicting peri-prosthetic femoral fracture in the early postoperative period. Material assignments for biphasic and triphasic models were undertaken. Failure modeling with the element deactivation feature available in ABAQUS 6.9 was used to simulate a crack initiation and propagation in the bony tissue based upon a threshold of fracture strain. The crack mode for the biphasic models was very similar to the experimental testing crack mode, with a similar shape and path of the crack. The fracture load is sensitive to the friction coefficient at the implant-bony interface. The development of a novel technique to simulate bone failure by element deactivation of subject-specific finite element models could aid prediction of fracture load in addition to fracture risk characterization for PFF. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Longo, F; Nicetto, T; Banzato, T; Savio, G; Drigo, M; Meneghello, R; Concheri, G; Isola, M
2018-02-01
The aim of this ex vivo study was to test a novel three-dimensional (3D) automated computer-aided design (CAD) method (aCAD) for the computation of femoral angles in dogs from 3D reconstructions of computed tomography (CT) images. The repeatability and reproducibility of three manual radiography, manual CT reconstructions and the aCAD method for the measurement of three femoral angles were evaluated: (1) anatomical lateral distal femoral angle (aLDFA); (2) femoral neck angle (FNA); and (3) femoral torsion angle (FTA). Femoral angles of 22 femurs obtained from 16 cadavers were measured by three blinded observers. Measurements were repeated three times by each observer for each diagnostic technique. Femoral angle measurements were analysed using a mixed effects linear model for repeated measures to determine the levels of intra-observer agreement (repeatability) and inter-observer agreement (reproducibility). Repeatability and reproducibility of measurements using the aCAD method were excellent (intra-class coefficients, ICCs≥0.98) for all three angles assessed. Manual radiography and CT exhibited excellent agreement for the aLDFA measurement (ICCs≥0.90). However, FNA repeatability and reproducibility were poor (ICCs<0.8), whereas FTA measurement showed slightly higher ICCs values, except for the radiographic reproducibility, which was poor (ICCs<0.8). The computation of the 3D aCAD method provided the highest repeatability and reproducibility among the tested methodologies. Copyright © 2017 Elsevier Ltd. All rights reserved.
Doherty, Michael; Courtney, Philip; Doherty, Sally; Jenkins, Wendy; Maciewicz, Rose A; Muir, Kenneth; Zhang, Weiya
2008-10-01
To determine whether 2-dimensional measures of femoral head shape and angle are associated with hip osteoarthritis (OA). We compared cases with symptomatic radiographic hip OA with asymptomatic controls with no radiographic hip OA. On anteroposterior pelvis radiographs, we measured "pistol grip deformity" for each hip (visually categorized as nonspherical, indeterminate, or spherical), the femoral head-to-femoral neck ratio as an interval measure of femoral head shape, and the femoral neck shaft angle. The relative risk of hip OA associated with each feature was estimated using odds ratios (ORs) and 95% confidence intervals (95% CIs), adjusted for possible confounders using a logistic regression model. Of 1,007 cases, 965 had definite radiographic hip OA; of 1,123 controls, 1,111 had no radiographic OA. The prevalence of pistol grip deformity in at least 1 hip was 3.61% in controls and 17.71% in cases (OR 6.95 [95% CI 4.64-10.41]), and the prevalence of abnormal femoral head-to-femoral neck ratio in at least 1 hip was 3.70% in controls and 24.27% in cases (OR 12.08 [95% CI 8.05-18.15]). The risk of hip OA increased as the femoral head-to-femoral neck ratio decreased (P for trend<0.001) and with each extreme of neck shaft angle (P<0.05). In cases with unilateral hip OA, the prevalence of abnormal femoral head-to-femoral neck ratio in the unaffected hip was 2 times greater than that in controls (OR 1.82 [95% CI 1.07-3.07]); in contrast, an abnormally low, but not abnormally high, neck shaft angle was more common in unaffected hips than in controls (OR 1.79 [95% CI 1.03-3.14]). Our findings indicate that pistol grip deformity is associated with hip OA. The increased prevalence of pistol grip deformity and an abnormally low neck shaft angle in unaffected hips of cases with unilateral OA suggests that they are risk factors for development of hip OA. However, both a nonspherical head shape and an increase in neck shaft angle may occur as a consequence of OA.
Proximal Femoral Reconstructions with Bone Impaction Grafting and Metal Mesh
Comba, Fernando; Piccaluga, Francisco
2009-01-01
Extensive circumferential proximal cortical bone loss is considered by some a contraindication for impaction bone grafting in the femur. We asked whether reconstruction with a circumferential metal mesh, impacted bone allografts, and a cemented stem would lead to acceptable survival in these patients. We retrospectively reviewed 14 patients (15 hips) with severe proximal femoral bone defects (average, 12 cm long; 14 type IV and one type IIIB using the classification of Della Valle and Paprosky) reconstructed with this method. The minimum followup was 20 months (average, 43.2 months; range, 20–72 months). Preoperative Merle D’Aubigné and Postel score averaged 4.8 points. With revision of the stem as the end point, the survivorship of the implant was 100% at one year and 86.6% at 72 months. The mean functional score at last followup was 14.4 points. We observed two fractures of the metal mesh at 31 and 48 months in cases reconstructed with a stem that did not bypass the mesh. Dislocation (3 cases) and acute deep infection (3 cases) were the most frequent complications. Patients with complete absence of the proximal femur may be candidates for biological proximal femoral reconstructions using this salvage procedure. Bone impaction grafting must be a routine technique if this method is selected. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:19294476
NASA Astrophysics Data System (ADS)
Tamez-Peña, José G.; Barbu-McInnis, Monica; Totterman, Saara
2006-03-01
Abnormal MR findings including cartilage defects, cartilage denuded areas, osteophytes, and bone marrow edema (BME) are used in staging and evaluating the degree of osteoarthritis (OA) in the knee. The locations of the abnormal findings have been correlated to the degree of pain and stiffness of the joint in the same location. The definition of the anatomic region in MR images is not always an objective task, due to the lack of clear anatomical features. This uncertainty causes variance in the location of the abnormality between readers and time points. Therefore, it is important to have a reproducible system to define the anatomic regions. This works present a computerized approach to define the different anatomic knee regions. The approach is based on an algorithm that uses unique features of the femur and its spatial relation in the extended knee. The femur features are found from three dimensional segmentation maps of the knee. From the segmentation maps, the algorithm automatically divides the femur cartilage into five anatomic regions: trochlea, medial weight bearing area, lateral weight bearing area, posterior medial femoral condyle, and posterior lateral femoral condyle. Furthermore, the algorithm automatically labels the medial and lateral tibia cartilage. The unsupervised definition of the knee regions allows a reproducible way to evaluate regional OA changes. This works will present the application of this automated algorithm for the regional analysis of the cartilage tissue.
Li, Zhang-hua; Liao, Wen; Cui, Xi-long; Zhao, Qiang; Liu, Ming; Chen, You-hao; Liu, Tian-shu; Liu, Nong-le; Wang, Fang; Yi, Yang; Shao, Ning-sheng
2011-01-09
In this study, we investigated the feasibility and safety of intravenous transplantation of allogeneic bone marrow mesenchymal stem cells (MSCs) for femoral head repair, and observed the migration and distribution of MSCs in hosts. MSCs were labeled with green fluorescent protein (GFP) in vitro and injected into nude mice via vena caudalis, and the distribution of MSCs was dynamically monitored at 0, 6, 24, 48, 72 and 96 h after transplantation. Two weeks after the establishment of a rabbit model of femoral head necrosis, GFP labeled MSCs were injected into these rabbits via ear vein, immunological rejection and graft versus host disease were observed and necrotic and normal femoral heads, bone marrows, lungs, and livers were harvested at 2, 4 and 6 w after transplantation. The sections of these tissues were observed under fluorescent microscope. More than 70 % MSCs were successfully labeled with GFP at 72 h after labeling. MSCs were uniformly distributed in multiple organs and tissues including brain, lungs, heart, kidneys, intestine and bilateral hip joints of nude mice. In rabbits, at 6 w after intravenous transplantation, GFP labeled MSCs were noted in the lungs, liver, bone marrow and normal and necrotic femoral heads of rabbits, and the number of MSCs in bone marrow was higher than that in the, femoral head, liver and lungs. Furthermore, the number of MSCs peaked at 6 w after transplantation. Moreover, no immunological rejection and graft versus host disease were found after transplantation in rabbits. Our results revealed intravenously implanted MSCs could migrate into the femoral head of hosts, and especially migrate directionally and survive in the necrotic femoral heads. Thus, it is feasible and safe to treat femoral head necrosis by intravenous transplantation of allogeneic MSCs.
Fiz, Nicolás; Delgado, Diego; Sánchez, Xabier; Sánchez, Pello; Bilbao, Ane Miren; Oraa, Jaime; Sánchez, Mikel
2017-10-01
In some surgical techniques like femoral derotation osteotomy, accuracy is a key factor that often is not optimal because of the lack of appropriate technology. 3D printing is emerging in many professional areas and its use in the medical field may enhance the results of certain surgeries. This case describes a patient who underwent an intramedullary nail fixation to treat a femoral shaft fracture. After nine months, the patient presented hip pain and "in toe" walking caused by a malrotation produced during the surgery. To address the consequent femoral derotation osteotomy, 3D technology was used throughout the whole process. A 3D model of the patient's femur was created to conduct a real and accuracy assessment of femoral anteversion. Then, a customized surgical guide was designed and printed to ensure the proper alignment during surgery. Given the success of this surgery, 3D printing can be considered a quick and inexpensive tool to improve surgical results.
Hernández-Cortés, Pedro; Monje, Alberto; Galindo-Moreno, Pablo; Catena, Andrés; Ortega-Oller, Inmaculada; Salas-Pérez, José; Mesa, Francisco; Gómez-Sánchez, Rafael; Aguilar, Mariano; Aguilar, David; O'Valle, Francisco
2014-01-01
This study was designed to explore relationships of resonance frequency analysis (RFA)-assessed implant stability (ISQ values) with bone morphometric parameters and bone quality in an ex vivo model of dental implants placed in human femoral heads and to evaluate the usefulness of this model for dental implant studies. This ex vivo study included femoral heads from 17 patients undergoing surgery for femoral neck fracture due to osteoporosis (OP) (n = 7) or for total prosthesis joint replacement due to severe hip osteoarthrosis (OA) (n = 10). Sixty 4.5 × 13 mm Dentsply Astra implants were placed, followed by RFA. CD44 immunohistochemical analysis for osteocytes was also carried out. As expected, the analysis yielded significant effects of femoral head type (OA versus OA) (P < 0.001), but not of the implants (P = 0.455) or of the interaction of the two factors (P = 0.848). Bonferroni post hoc comparisons showed a lower mean ISQ for implants in decalcified (50.33 ± 2.92) heads than in fresh (66.93 ± 1.10) or fixated (70.77 ± 1.32) heads (both P < 0.001). The ISQ score (fresh) was significantly higher for those in OA (73.52 ± 1.92) versus OP (67.13 ± 1.09) heads. However, mixed linear analysis showed no significant association between ISQ scores and morphologic or histomorphometric results (P > 0.5 in all cases), and no significant differences in ISQ values were found as a function of the length or area of the cortical layer (both P > 0.08). Although RFA-determined ISQ values are not correlated with morphometric parameters, they can discriminate bone quality (OP versus OA). This ex vivo model is useful for dental implant studies.
Shi, Jingsheng; Chen, Jie; Wu, Jianguo; Chen, Feiyan; Huang, Gangyong; Wang, Zhan; Zhao, Guanglei; Wei, Yibing; Wang, Siqun
2014-01-01
Background The aim of this study was to contrast the collapse values of the postoperative weight-bearing areas of different tantalum rod implant positions, fibula implantation, and core decompression model and to investigate the advantages and disadvantages of tantalum rod implantation in different ranges of osteonecrosis in comparison with other methods. Material/Methods The 3D finite element method was used to establish the 3D finite element model of normal upper femur, 3D finite element model after tantalum rod implantation into different positions of the upper femur in different osteonecrosis ranges, and other 3D finite element models for simulating fibula implant and core decompression. Results The collapse values in the weight-bearing area of the femoral head of the tantalum rod implant model inside the osteonecrosis area, implant model in the middle of the osteonecrosis area, fibula implant model, and shortening implant model exhibited no statistically significant differences (p>0.05) when the osteonecrosis range was small (60°). The stress values on the artificial bone surface for the tantalum rod implant model inside the osteonecrosis area and the shortening implant model exhibited statistical significance (p<0.01). Conclusions Tantalum rod implantation into the osteonecrosis area can reduce the collapse values in the weight-bearing area when osteonecrosis of the femoral head (ONFH) was in a certain range, thereby obtaining better clinical effects. When ONFH was in a large range (120°), the tantalum rod implantation inside the osteonecrosis area, shortening implant or fibula implant can reduce the collapse values of the femoral head, as assessed by other methods. PMID:25479830
[Changes of blood vessels in glucocorticoid-induced avascular necrosis of femoral head in rabbits].
Zhou, Q; Li, Q; Yang, L; Liu, F
2000-03-01
To evaluate the effects of fatty tamponade in medullary cavity (serious intramedullary fatty infiltration) on the changes of blood vessels in femoral heads during the pathological process of glucocorticoid (GC)-induced avascular necrosis (AVM) of the femoral heads. The animal model of AVN was established with injection of dexamethasone (DEX) at a high dose of 2.5 mg x kg(-1) x d(-1) in rabbits. Histopathological and morphological changes of blood vessels in the femoral heads were investigated during GC-treatment and after the cessation scanning electron microscope, light microscope, and image analysis. At the 2nd week of DEX-treatment, the fatty tamponade in the medullary cavity appeared in the femoral heads. Intramedullary vascular sinusoids were pressed by an excess of lipocytes and became narrow. The impressions of lipocytes on the surface of vascular sinusoids were definitely displayed on the vascular casts and ink-perfused slides of the femoral heads. These changes were pronounced with the prolongation of the treatment and the vascular sinusoids gradually lost their characteristics. Image analysis showed that the vascular area in the femoral heads continuously decreased. At the 8th week, the effects of fatty tamponade were the most marked. Intramedullary vessels became very sparse and the vascular area decreased to 1/4 of the controls. At the 6th week after the GC-treatment cessation, intramedullary fatty infiltration still existed. The blood vessels were fine and sparse, and the structural features of vascular sinusoids disappeared in the load-bearing regions of the femoral heads. At the 4th week, typical osteonecrosis focuses appeared in the femoral heads. The focuses became larger and the degree of osteonecrosis was increasing with the time of experiment. The fatty tamponade in the medullary cavity is one of the important pathological factors causing ischemic damage to the femoral heads, and plays an important role in the early stage of GC-induced AVN.
USDA-ARS?s Scientific Manuscript database
Femoral head separation (FHS) is an idiopathic bone problem that causes lameness and production losses in commercial poultry. In a model of prednisolone induced susceptibility to FHS, the changes in plasma proteins and peptides were analyzed to find possible biomarkers. Plasma from control and FHS-s...
Alterations of sympathetic nerve fibers in avascular necrosis of femoral head.
Li, Deqiang; Liu, Peilai; Zhang, Yuankai; Li, Ming
2015-01-01
Avascular necrosis of the femoral head (ANFH) was mainly due to alterations of bone vascularity. And noradrenaline (NA), as the neurotransmitter of the sympathetic nervous system (SNS), leads to the vasoconstriction by activating its α-Receptor. This study was to explore the nerve fiber density of the femoral head in the rabbit model of ANFH. Twenty New Zealand white rabbits were used in this study. The rabbit model of ANFH was established by the injection of methylprednisolone acetate. The nerve fiber density and distribution in the femoral head was determined using an Olympus BH2 microscope. Significant fewer sympathetic nerve fibers was found in the ANFH intertrochanteric bone samples (P = 0.036) with osteonecrosis. The number of sympathetic nerve fibers was compared between the two groups. And less sympathetic nerve fibers were found in later stage ANFH samples in comparison with those of early stages. ANFH might be preceded by an inflammatory reaction, and an inflammatory response might lead to arthritic changes in tissue samples, which in turn reduces the number of sympathetic nerve fibers.
Peripheral Blood Mononuclear Cells Enhance Cartilage Repair in in vivo Osteochondral Defect Model.
Hopper, Niina; Wardale, John; Brooks, Roger; Power, Jonathan; Rushton, Neil; Henson, Frances
2015-01-01
This study characterized peripheral blood mononuclear cells (PBMC) in terms of their potential in cartilage repair and investigated their ability to improve the healing in a pre-clinical large animal model. Human PBMCs were isolated with gradient centrifugation and adherent PBMC's were evaluated for their ability to differentiate into adipogenic, chondrogenic and osteogenic lineages and also for their expression of musculoskeletal genes. The phenotype of the PBMCs was evaluated using Stro-1, CD34, CD44, CD45, CD90, CD106, CD105, CD146 and CD166 cell surface markers. Osteochondral defects were created in the medial femoral condyle (MFC) of 24 Welsh mountain sheep and evaluated at a six month time point. Four cell treatment groups were evaluated in combination with collagen-GAG-scaffold: (1) MSC alone; (2) MSCs and PBMCs at a ratio of 20:1; (3) MSCs and PBMC at a ratio of 2:1 and (4) PBMCs alone. Samples from the surgical site were evaluated for mechanical properties, ICRS score and histological repair. Fresh PBMC samples were 90% positive for hematopoietic cell surface markers and negative for the MSC antibody panel (<1%, p = 0.006). However, the adherent PBMC population expressed mesenchymal stem cell markers in hypoxic culture and lacked CD34/45 positive cells (<0.2%). This finding demonstrated that the adherent cells had acquired an MSC-like phenotype and transformed in hypoxia from their original hematopoietic lineage. Four key genes in muskuloskeletal biology were significantly upregulated in adherent PBMCs by hypoxia: BMP2 4.2-fold (p = 0.0007), BMP6 10.7-fold (p = 0.0004), GDF5 2.0-fold (p = 0.002) and COL1 5.0-fold (p = 0.046). The monolayer multilineage analysis confirmed the trilineage mesenchymal potential of the adherent PBMCs. PBMC cell therapy was equally good as bone marrow MSC therapy for defects in the ovine large animal model. Our results show that PBMCs support cartilage healing and oxygen tension of the environment was found to have a key effect on the derivation of a novel adherent cell population with an MSC-like phenotype. This study presents a novel and easily attainable point-of-care cell therapy with PBMCs to treat osteochondral defects in the knee avoiding any cell manipulations outside the surgical room.
Li, Zhanghua; Liao, Wen; Zhao, Qiang; Liu, Ming; Xia, Wei; Yang, Yi; Shao, Ningsheng
2013-07-01
To explore the feasibility of allogeneic mesenchymal stem cells (MSCs) transplanted intravenously for angiogenesis and bone repair in a rabbit model of avascular necrosis of femoral head (ANFH). Forty-five rabbits were randomized into three groups: a blank control group (without treatment), a necrotic control group (ANFH induced but without therapy), and an MSC transplantation group (ANFH induced and treated with MSC transplantation). The biopsies, blood sampling, and imaging examinations were performed on each animal at different time points (2, 4, and 6 wk). To monitor angiogenesis and bone repair progress, examinations included real-time polymerase chain reaction, Western blot analysis, x-ray, computed tomography, Masson trichrome staining, picrosirius red staining, and immunohistochemical staining. Necrosis and bone collapse were observed in bilateral femoral heads of necrotic rabbits of the necrotic control group, whereas the femoral head morphology was generally restored in the MSC transplantation group. The mRNA levels of Cbfa1, BMP, VEGF, and OPN in bone tissue were significantly higher in the MSC transplantation group than in the necrotic control group. In addition, the total protein amount of Cbfa1 in the MSC transplantation group was also significantly higher than that in the necrotic control group (P < 0.05). Intravenous transplantation of allogeneic MSCs can promote vascular and bone regeneration in the necrotic region of the femoral head in a rabbit model of ANFH. The results of our study suggest that the intravenous transplantation of MSCs could be a potential and minimally invasive treatment option for ANFH patients. Copyright © 2013 Elsevier Inc. All rights reserved.
Tao, Zhou-Shan; Zhou, Wan-Shu; Wu, Xin-Jing; Wang, Lin; Yang, Min; Xie, Jia-Bing; Xu, Zhu-Jun; Ding, Guo-Zheng
2018-02-01
Parathyroid hormone (1-34, PTH) combined β-tricalcium phosphate (β-TCP) achieves stable bone regeneration without cell transplantation in previous studies. Recently, with the development of tissue engineering slow release technology, PTH used locally to promote bone defect healing become possible. This study by virtue of collagen with a combination of drugs and has a slow release properties, and investigated bone regeneration by β-TCP/collagen (β-TCP/COL) with the single local administration of PTH. After the creation of a rodent critical-sized femoral metaphyseal bone defect, β-TCP/COL was prepared by mixing sieved granules of β-TCP and atelocollagen for medical use, then β-TCP/COL with dripped PTH solution (1.0 µg) was implanted into the defect of OVX rats until death at 4 and 8 weeks. The defected area in distal femurs of rats was harvested for evaluation by histology, micro-CT, and biomechanics. The results of our study show that single-dose local administration of PTH combined local usage of β-TCP/COL can increase the healing of defects in OVX rats. Furthermore, treatments with single-dose local administration of PTH and β-TCP/COL showed a stronger effect on accelerating the local bone formation than β-TCP/COL used alone. The results from our study demonstrate that combination of single-dose local administration of PTH and β-TCP/COL had an additive effect on local bone formation in osteoporosis rats.
Rue, John-Paul H; Ghodadra, Neil; Bach, Bernard R
2008-01-01
There is controversy regarding the necessity of reconstructing both the posterolateral and anteromedial bundles of the anterior cruciate ligament. A laterally oriented transtibial drilled femoral tunnel replaces portions of the femoral footprints of the anteromedial and posterolateral bundles of the anterior cruciate ligament. Descriptive laboratory study. Footprints of the anteromedial and posterolateral bundles of the anterior cruciate ligament were preserved on 7 matched pairs (5 female, 2 male) of fresh-frozen human cadaveric femurs (14 femurs total). Each femur was anatomically oriented and secured in a custom size-appropriate, side-matched replica tibia model to simulate transtibial retrograde drilling of a 10-mm femoral tunnel in each specimen. The relationship of the tunnel relative to footprints of both bundles of the anterior cruciate ligament was recorded using a Microscribe MX digitizer. The angle of the femoral tunnel relative to the vertical 12-o'clock position was recorded for all 14 specimens; only 10 specimens were used for footprint measurements. On average, the 10-mm femoral tunnel overlapped 50% of the anteromedial bundle (range, 2%-83%) and 51% of the posterolateral bundle (range, 16%-97%). The footprint of the anteromedial bundle occupied 32% (range, 3%-49%) of the area of the tunnel; the footprint of the posterolateral bundle contributed 26% (range, 7%-41%). The remainder of the area of the 10-mm tunnel did not overlap with the anterior cruciate ligament footprint. The mean absolute angle of the femoral tunnel as measured directly on the specimen was 48 degrees (range, 42 degrees-53 degrees) from vertical, corresponding to approximately a 10:30 clock face position on a right knee. Anterior cruciate ligament reconstruction using a laterally oriented transtibial drilled femoral tunnel incorporates portions of the anteromedial and posterolateral bundle origins of the native anterior cruciate ligament. A laterally oriented transtibial drilled femoral tunnel placed at the 10:30 position (1:30 for left knees) reconstructs portions of the anteromedial and posterolateral bundles of the anterior cruciate ligament.
Okazaki, Ken; Osaki, Kanji; Nishikawa, Kazutaka; Matsubara, Hirokazu; Tashiro, Yasutaka; Iwamoto, Yukihide
2016-08-01
When the femoral tunnel socket is reamed in an oblique direction from the wall of inter-condylar notch in anterior cruciate ligament (ACL) reconstruction, the tunnel length can be shorter at the periphery than at the centre. Because surgeons can manipulate the direction of tunnel in the outside-in femoral tunnel drilling technique, this length mismatch would vary depending on the direction of the tunnel. The purpose of this study was to investigate this length mismatch when reamed in various directions. In total of thirteen points were defined as femoral drilling entry points on concentric lines with 0, 1, 2, and 3 cm radius from the lateral epicondyle of a three-dimensional bone model from 40 subjects. Femoral tunnel drilling was simulated on the models by connecting the centre of the ACL footprint with each defined point on the lateral femoral surface. The mismatch length was measured between the centre and the shortest peripheral side of the tunnel socket. When the distance between the drilling entry point on the lateral femoral surface and the lateral epicondyle was increased to anterior proximal direction, there was a significant increase in the mismatch length. The mismatch length became more than 2 mm when the entry point was located more than 2 cm away from the lateral epicondyle. When the drilling entry point is set far away from the lateral epicondyle, a significant increase was observed in tunnel length mismatch between the centre of the tunnel and its shortest peripheral side. Because the tunnel length is measured with a guide pin introduced at the centre of the tunnel before reaming in retrograde outside-in technique, this length mismatch could cause an overestimation of the tunnel length. Surgeons should recognise this mismatch when preparing the length of graft and socket to optimise the graft insertion length into the socket.
Ahmad Hatem, Munif; Ferreira da Luz, Bernardo; Nishimoto Nishi, Rodrigo; Gilberto Cimbalista de Alencar, Paulo
2014-01-01
Objective To evaluate the results from proximal fixation of uncemented conical femoral components in patients with a type C proximal femur and compare them with the results obtained from type A and B femurs. Methods This was a retrospective study on 87 patients with 90 uncemented total hip arthroplasty procedures. Three patients (three hips) were excluded because their follow-up lasted for less than two years. The follow-up ranged from 2 to 4.3 years and the mean was 2.8 years. The Bicontact femoral implant model was used. The preoperative radiographs were evaluated, the femurs were classified as Dorr types A, B or C and the cortical indices were measured. The patients were evaluated clinically by means of the Harris Hip Score (HHS), before the surgery and at the last follow-up. The sequences of postoperative radiographs were compared regarding stability, complications and any signs of osseointegration of the femoral prosthesis. Results Among the 87 hips with follow-up greater than two years, 32 femurs were type A (37%), 37 type B (42%) and 18 type C (21%). Before the operation, the mean HHS was 39.4 for types A and B and 38.8 for type C. At the last follow-up, the mean HHS was 89.8 for types A and B and 86 for type C. None of the 87 femoral components had been revised by the time of the last follow-up; all of them were considered stable. In 86 cases, the radiographs showed signs of osseointegration. Conclusion There were no significant differences in the clinical results or in the fixation (and osseointegration) of conical uncemented femoral prostheses with proximal porosity, among femurs with different types of femoral morphology according to the Dorr classification. This conclusion may vary if another implant model were to be used. PMID:26229810
Doshi, Ankur M; Hoffman, David; Kierans, Andrea S; Ream, Justin M; Rosenkrantz, Andrew B
2015-10-01
The objective of this study is to assess the performance of qualitative and quantitative imaging features for the differentiation of deep venous thrombosis (DVT) from mixing artifact on routine portal venous phase abdominopelvic CT. This retrospective study included 40 adult patients with a femoral vein filling defect on portal venous phase CT and a Duplex ultrasound (n = 36) or catheter venogram (n = 4) to confirm presence or absence of DVT. Two radiologists (R1, R2) assessed the femoral veins for various qualitative and quantitative features. 60% of patients were confirmed to have DVT and 40% had mixing artifact. Features with significantly greater frequency in DVT than mixing artifact (all p ≤ 0.006) were central location (R1 90% vs. 28%; R2 96% vs. 31%), sharp margin (R1 83% vs. 28%; R2 96% vs. 31%), venous expansion (R1 48% vs. 6%, R2 56% vs. 6%), and venous wall enhancement (R1 62% vs. 0%; R2 48% vs. 0%). DVT exhibited significantly lower mean attenuation than mixing artifact (R1 42.1 ± 20.2 vs. 57.1 ± 23.6 HU; R2 43.6 ± 19.4 vs. 58.8 ± 23.4 HU, p ≤ 0.031) and a significantly larger difference in vein diameter compared to the contralateral vein (R1 0.4 ± 0.4 vs. 0.1 ± 0.2 cm; R2 0.3 ± 0.4 vs. 0.0 ± 0.1 cm, p ≤ 0.026). At multivariable analysis, central location and sharp margin were significant independent predictors of DVT for both readers (p ≤ 0.013). Awareness of these qualitative and quantitative imaging features may improve radiologists' confidence for differentiating femoral vein DVT and mixing artifact on routine portal venous phase CT. However, given overlap with mixing artifact, larger studies remain warranted.
Sirri, F; Maiorano, G; Tavaniello, S; Chen, J; Petracci, M; Meluzzi, A
2016-08-01
The aim of the experiment was to assess the effects of 2 dietary levels of trace minerals (TM) zinc, manganese, and copper either from organic (OTM) or inorganic (ITM) sources on broiler performance, carcass traits, intramuscular collagen (IMC) properties, occurrence of hock burns (HB), foot pad dermatitis (FPD), femoral and tibia head necrosis, and breast muscle abnormalities (white striping, WS; wooden breast, WB; poor cohesion, PC). A total of 3,600 one-day-old male chicks were randomly assigned to one of 4 dietary treatments in a 2 × 2 factorial arrangement (9 replicates of 100 birds/dietary treatment). Birds were slaughtered at 31 (thinning) and 51 d of age. Body weight, daily weight gain (DWG), feed intake, feed conversion rate (FCR), and mortality were determined. A significant effect of the source of TM supplementation was found only in 51-day-old chickens. Birds of the OTM groups were heavier (P < 0.05), with a higher (P < 0.05) DWG and a better FCR (P < 0.05) compared with those of the ITM groups. OTM significantly reduced the lesion scores of femoral head (P = 0.004) and total leg (femur + tibia, P = 0.02) compared to ITM, which is mainly caused by the reduction of the percentages of femoral head transitional degeneration (FHT, P = 0.04) and femoral head necrosis (FHN, P = 0.07). Carcass traits were similar among the experimental groups. No alleviating effect of TM administration on the incidence of FPD and HB in 31- and 51-day-old chickens was found. Similarly, the occurrence and the degrees of WS and WB in 51-day-old chickens was affected neither by the doses nor by the source of TM supplied. IMC characteristics of broiler pectoral muscle were not affected (P > 0.05) by the different sources and doses of TM administrated. © 2016 Poultry Science Association Inc.
Megas, Panagiotis; Georgiou, Christos S; Panagopoulos, Andreas; Kouzelis, Antonis
2014-12-31
The transfemoral and the extended trochanteric osteotomies are the most common osteotomies used in femoral revision, both when proximal or diaphyseal fixation of the new component has been decided. We present an alternative approach to the trochanteric osteotomies, most frequently used with distally fixated stems, to overcome their shortcomings of osteotomy migration and nonunion, but, most of all, the uncontrollable fragmentation of the femur. The procedure includes a complete circular femoral osteotomy just below the stem tip to prevent distal fracture propagation and a subsequent preplanned segmentation of the proximal femur for better exposure and fast removal of the old prosthesis. The bone fragments are reattached with cerclage wires to the revision prosthesis, which is safely anchored distally. A modified posterolateral approach is used, as the preservation of the continuity of the abductors, the greater trochanter, and the vastus lateralis is a prerequisite. Between 2006 and 2012, 47 stems (33 women, 14 men, mean age 68 years, range 39-88 years) were revised using this technique. They were 12 (26%) stable and 35 (74%) loose prostheses and were all revised to tapered, fluted, grit-blasted stems. No fracture of the trochanters or the distal femur occurred intraoperatively. Mean follow-up was 28 months (range 6-70 months). No case of trochanteric migration or nonunion of the osteotomies was recorded. Restoration of the preexisting bone defects occurred in 83% of the patients. Three patients required repeat revision due to dislocation and one due to a postoperative periprosthetic fracture. None of the failures was attributed to the procedure itself. This new osteotomy technique may seem aggressive at first, but, at least in our hands, has effectively increased the speed of the femoral revision, particularly for the most difficult well-fixed components, but not at the expense of safety.
[Influence of shenxu gutong capsule on femoral inorganic elements content and ash weight in rats].
Chen, X; Wei, J; Chen, Y
1998-02-01
To explore the mechanism of Shenxu Gutong Capsule (SXGTC) in treating postmenopausal osteoporosis. Using ovariectomized rats as the model of postmenopausal osteoporosis, the effect of SXGTC on inorganic element content of femur and femoral ash weight of the model rats were surveyed. Animals were divided into model group, SXGTC high dose group, SXGTC low dose group, positive control group (treated with Gushukang) and normal control group. The medication began at one week after operation and lasting for 120 days. The contents of inorganic elements, including Ca, P, Mg, Zn, Cu and Mn in the three medicated groups were higher than those of the model group (P < 0.01). The effect of SXGTC was dose dependent. The difference between the SXGTC groups and the positive control group was insignificant. The femoral ash weight of the SXGTC high dose group and the positive control group was significantly higher than that of the model group (P < 0.01). SXGTC could antagonize the rat's bony change caused by ovariectomy to increase the inorganic contents in bone, which may, in grneral, lead to a bone-strengthening effect.
In Vivo Hypobaric Hypoxia Performed During the Remodeling Process Accelerates Bone Healing in Mice
Durand, Marjorie; Collombet, Jean-Marc; Frasca, Sophie; Begot, Laurent; Lataillade, Jean-Jacques; Le Bousse-Kerdilès, Marie-Caroline
2014-01-01
We investigated the effects of respiratory hypobaric hypoxia on femoral bone-defect repair in mice because hypoxia is believed to influence both mesenchymal stromal cell (MSC) and hematopoietic stem cell mobilization, a process involved in the bone-healing mechanism. To mimic conditions of non-weight-bearing limb immobilization in patients suffering from bone trauma, our hypoxic mouse model was further subjected to hind-limb unloading. A hole was drilled in the right femur of adult male C57/BL6J mice. Four days after surgery, mice were subjected to hind-limb unloading for 1 week. Seven days after surgery, mice were either housed for 4 days in a hypobaric room (FiO2 at 10%) or kept under normoxic conditions. Unsuspended control mice were housed in either hypobaric or normoxic conditions. Animals were sacrificed on postsurgery day 11 to allow for collection of both contralateral and lesioned femurs, blood, and spleen. As assessed by microtomography, delayed hypoxia enhanced bone-healing efficiency by increasing the closing of the cortical defect and the newly synthesized bone volume in the cavity by +55% and +35%, respectively. Proteome analysis and histomorphometric data suggested that bone-repair improvement likely results from the acceleration of the natural bone-healing process rather than from extended mobilization of MSC-derived osteoprogenitors. Hind-limb unloading had hardly any effect beyond delayed hypoxia-enhanced bone-healing efficiency. PMID:24944208
Ishihara, Akikazu; Weisbrode, Steve E; Bertone, Alicia L
2015-10-01
Cell-mediated gene therapy may treat bone fragility disorders. Dermal fibroblasts (DFb) may be an alternative cell source to stem cells for orthopedic gene therapy because of their rapid cell yield and excellent plasticity with bone morphogenetic protein-2 (BMP2) gene transduction. Autologous DFb or BMP2-expressing autologous DFb were administered in twelve rabbits by two delivery routes; a transcortical intra-medullar infusion into tibiae and delayed intra-osseous injection into femoral drill defects. Both delivery methods of DFb-BMP2 resulted in a successful cell engraftment, increased bone volume, bone mineral density, improved trabecular bone microarchitecture, greater bone defect filling, external callus formation, and trabecular surface area, compared to non-transduced DFb or no cells. Cell engraftment within trabecular bone and bone marrow tissue was most efficiently achieved by intra-osseous injection of DFb-BMP2. Our results suggested that BMP2-expressing autologous DFb have enhanced efficiency of engraftment in target bones resulting in a measurable biologic response by the bone of improved bone mineral density and bone microarchitecture. These results support that autologous implantation of DFb-BMP2 warrants further study on animal models of bone fragility disorders, such as osteogenesis imperfecta and osteoporosis to potentially enhance bone quality, particularly along with other gene modification of these diseases. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Prieto, Edna M.; Talley, Anne D.; Gould, Nicholas R.; Zienkiewicz, Katarzyna J.; Drapeau, Susan J.; Kalpakci, Kerem N.
2014-01-01
Established clinical approaches to treat bone voids include the implantation of autograft or allograft bone, ceramics, and other bone void fillers (BVFs). Composites prepared from lysine-derived polyurethanes and allograft bone can be injected as a reactive liquid and set to yield BVFs with mechanical strength comparable to trabecular bone. In this study, we investigated the effects of porosity, allograft particle size, and matrix mineralization on remodeling of injectable and settable allograft/polymer composites in a rabbit femoral condyle plug defect model. Both low viscosity (LV) and high viscosity (HV) grafts incorporating small (<105 μm) particles only partially healed at 12 weeks, and the addition of 10% demineralized bone matrix did not enhance healing. In contrast, composite grafts with large (105 – 500 μm) allograft particles healed at 12 weeks post-implantation, as evidenced by radial μCT and histomorphometric analysis. This study highlights particle size and surface connectivity as influential parameters regulating the remodeling of composite bone scaffolds. PMID:25581686
Long, Hua; Zheng, Liheng; Gomes, Fernando Cardoso; Zhang, Jinhui; Mou, Xiang; Yuan, Hua
2013-09-01
To clarify the effects of low sound pressure level (LSPL) infrasound on local bone turnover and explore its underlying mechanisms, femoral defected rats were stabilized with a single-side external fixator. After exposure to LSPL infrasound for 30min twice everyday for 6 weeks, the pertinent features of bone healing were assessed by radiography, peripheral quantitative computerized tomography (pQCT), histology and immunofluorescence assay. Infrasound group showed a more consecutive and smoother process of fracture healing and modeling in radiographs and histomorphology. It also showed significantly higher average bone mineral content (BMC) and bone mineral density (BMD). Immunofluorescence showed increased expression of calcitonin gene related peptide (CGRP) and decreased Neuropeptide Y (NPY) innervation in microenvironment. The results suggested the osteogenesis promotion effects of LSPL infrasound in vivo. Neuro-osteogenic network in local microenvironment was probably one target mediating infrasonic osteogenesis, which might provide new strategy to accelerate bone healing and remodeling. Copyright © 2013 Elsevier B.V. All rights reserved.
Li, Jun-Hui; Wu, Ya-Ling; Ye, Jian-Hong; Ning, Ya-Gong; Yu, Hai-Ying; Peng, Zhong-Jie; Luan, Xiao-Wen
2009-09-01
To observe the promoting effects of blood-activating and stasis-removing Chinese drugs combined with vascular endothelial growth factor (VEGF) gene transfer on angiogenesis in ischemic necrosis of the femoral head. Forty Japanese giant-ear rabbits were randomly divided into a control group, a model group, a Chinese drug group, a gene group, and a combined group. After 8 weeks of treatment, the rate of VEGF positive cell expression in the synovium of the femoral head was measured using the immunohistochemical method, and the number of blood vessels in the femoral head was measured by digital subtraction angiography. The rate of VEGF positive cell expression in the model group was significantly lower than that in the Chinese drug group (P < 0.05) and very significantly lower than those in other groups (P < 0.01); but in the combined group it was significantly higher than in the Chinese drug group (P < 0.05). The differences in the number of blood vessels in area A between the model group and other groups were not statistically significant. However, in area B, the number of blood vessels significantly increased in the control group, the gene group and the combined group as compared with the model group (P < 0.05), and in the combined group the number of blood vessels was significantly more than in the gene group (P < 0.05); but in the Chinese drug group it was not significantly different than the model group (P > 0.05). Either the blood-activating and stasis-removing Chinese drugs or VEGF gene transfer can promote the angiogenesis and building of collateral circulation for femoral head ischemic necrosis, and the combined therapy with Chinese drugs or VEGF gene transfer may show a better therapeutic effect. The present study provides an experimental basis for clinical application of the combined therapy with the blood-activating and stasis-removing Chinese drugs and VEGF gene transfer.
Image analysis software as a strategy to improve the radiographic determination of fracture healing.
Duryea, Jeffrey; Evans, Christopher; Glatt, Vaida
2018-05-28
To develop and validate an unbiased, accurate, convenient and inexpensive means of determining when an osseous defect has healed and recovered sufficient strength to allow weight-bearing. A novel image processing software algorithm was created to analyze the radiographic images and produce a metric designed to reflect the bone strength. We used a rat femoral segmental defect model that provides a range of healing responses from complete union to non-union. Femora were examined by X-ray, micro-computed tomography (µCT) and mechanical testing. Accurate simulated radiographic images at different incident X-ray beam angles were produced from the µCT data files. The software-generated metric (SC) showed high levels of correlation with both the mechanical strength (τMech) and the polar moment of inertia (pMOI), with the mechanical testing data having the highest association. The optimization analysis yielded optimal oblique angles θB of 125° for τMech and 50° for pMOI. The Pearson's R values for the optimized model were 0.71 and 0.64 for τMech and pMOI, respectively. Further validation using true radiographs also demonstrated that the metric was accurate, and that the simulations were realistic. The preliminary findings suggest a very promising methodology to assess bone fracture healing using conventional radiography. With radiographs acquired at appropriate incident angles, it proved possible to calculate accurately the degree of healing and the mechanical strength of the bone. Further research is necessary to refine this approach and determine whether it translates to the human clinical setting.
Shimomura, Kazunori; Ando, Wataru; Tateishi, Kosuke; Nansai, Ryosuke; Fujie, Hiromichi; Hart, David A; Kohda, Hideyuki; Kita, Keisuke; Kanamoto, Takashi; Mae, Tatsuo; Nakata, Ken; Shino, Konsei; Yoshikawa, Hideki; Nakamura, Norimasa
2010-11-01
One of the potential factors that may affect the results of mesenchymal stem cell (MSC)-based therapy is the age of donors and recipients. However, there have been no controlled studies to investigate the influence of skeletal maturity on the MSC-based repair of cartilage. The purpose of this study was to compare the repair quality of damaged articular cartilage treated by a scaffold-free three-dimensional tissue-engineered construct (TEC) derived from synovial MSCs between immature and mature pigs. Synovial MSCs were isolated from immature and mature pigs and the proliferation and chondrogenic differentiation capacities were compared. The TEC derived from the synovial MSCs were then implanted into equivalent chondral defects in the medial femoral condyle of both immature and mature pigs, respectively. The implanted defects were morphologically and biomechanically evaluated at 6 months postoperatively. There was no skeletal maturity-dependent difference in proliferation or chondrogenic differentiation capacity of the porcine synovial MSCs. The TEC derived from synovial MSCs promoted the repair of chondral lesion in both immature and mature pigs without the evidence of immune reaction. The repaired tissue by the TEC also exhibited similar viscoelastic properties to normal cartilage regardless of the skeletal maturity. The results of the present study not only suggest the feasibility of allogenic MSC-based cartilage repair over generations but also may validate the use of immature porcine model as clinically relevant to test the feasibility of synovial MSC-based therapies in chondral lesions. Copyright 2010 Elsevier Ltd. All rights reserved.
Motoneuron regeneration accuracy and recovery of gait after femoral nerve injuries in rats.
Kruspe, M; Thieme, H; Guntinas-Lichius, O; Irintchev, A
2014-11-07
The rat femoral nerve is a valuable model allowing studies on specificity of motor axon regeneration. Despite common use of this model, the functional consequences of femoral nerve lesions and their relationship to precision of axonal regeneration have not been evaluated. Here we assessed gait recovery after femoral nerve injuries of varying severity in adult female Wistar rats using a video-based approach, single-frame motion analysis (SFMA). After nerve crush, recovery was complete at 4 weeks after injury (99% of maximum 100% as estimated by a recovery index). Functional restoration after nerve section/suture was much slower and incomplete (84%) even 20 weeks post-surgery. A 5-mm gap between the distal and proximal nerve stumps additionally delayed recovery and worsened the outcome (68% recovery). As assessed by retrograde labeling in the same rats at 20 weeks after injury, the anatomical outcome was also dependent on lesion severity. After nerve crush, 97% of the femoral motoneurons (MNs) had axons correctly projecting only into the distal quadriceps branch of the femoral nerve. The percentage of correctly projecting MNs was only 55% and 15% after nerve suture and gap repair, respectively. As indicated by regression analyses, better functional recovery was associated with higher numbers of correctly projecting MNs and, unexpectedly, lower numbers of MNs projecting to both muscle and skin. The data show that type of nerve injury and repair profoundly influence selectivity of motor reinnervation and, in parallel, functional outcome. The results also suggest that MNs' projection patterns may influence their contribution to muscle performance. In addition to the experiments described above, we performed repeated measurements and statistical analyses to validate the SFMA. The results revealed high accuracy and reproducibility of the SFMA measurements. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.
Gupta, Chandra Prakash; Kureel, Jyoti; Mansoori, Mohd Nizam; Shukla, Priyanka; John, Aijaz A.; Singh, Kavita; Purohit, Dipak; Awasthi, Pallavi; Singh, Divya; Goel, Atul
2015-01-01
We evaluated the bone regeneration and healing effect of Medicarpin (med) in cortical bone defect model that heals by intramembranous ossification. For the study, female Sprague–Dawley rats were ovariectomized and rendered osteopenic. A drill hole injury was generated in mid femoral bones of all the animals. Med treatment was commenced the day after and continued for 15 days. PTH was taken as a reference standard. Fifteen days post-treatment, animals were sacrificed. Bones were collected for histomorphometry studies at the injury site by micro-computed tomography (μCT) and confocal microscopy. RNA and protein was harvested from newly generated bone. For immunohistochemistry, 5μm sections of decalcified femur bone adjoining the drill hole site were cut. By μCT analysis and calcein labeling of newly generated bone it was found that med promotes bone healing and new bone formation at the injury site and was comparable to PTH in many aspects. Med treatment led to increase in the Runx-2 and osteocalcin signals indicating expansion of osteoprogenitors at the injury site as evaluated by qPCR and immunohistochemical localization. It was observed that med promoted bone regeneration by activating canonical Wnt and notch signaling pathway. This was evident by increased transcript and protein levels of Wnt and notch signaling components in the defect region. Finally, we confirmed that med treatment leads to elevated bone healing in pre-osteoblasts by co localization of beta catenin with osteoblast marker alkaline phosphatase. In conclusion, med treatment promotes new bone regeneration and healing at the injury site by activating Wnt/canonical and notch signaling pathways. This study also forms a strong case for evaluation of med in delayed union and non-union fracture cases. PMID:26657206
Dixit, Manisha; Raghuvanshi, Ashutosh; Gupta, Chandra Prakash; Kureel, Jyoti; Mansoori, Mohd Nizam; Shukla, Priyanka; John, Aijaz A; Singh, Kavita; Purohit, Dipak; Awasthi, Pallavi; Singh, Divya; Goel, Atul
2015-01-01
We evaluated the bone regeneration and healing effect of Medicarpin (med) in cortical bone defect model that heals by intramembranous ossification. For the study, female Sprague-Dawley rats were ovariectomized and rendered osteopenic. A drill hole injury was generated in mid femoral bones of all the animals. Med treatment was commenced the day after and continued for 15 days. PTH was taken as a reference standard. Fifteen days post-treatment, animals were sacrificed. Bones were collected for histomorphometry studies at the injury site by micro-computed tomography (μCT) and confocal microscopy. RNA and protein was harvested from newly generated bone. For immunohistochemistry, 5μm sections of decalcified femur bone adjoining the drill hole site were cut. By μCT analysis and calcein labeling of newly generated bone it was found that med promotes bone healing and new bone formation at the injury site and was comparable to PTH in many aspects. Med treatment led to increase in the Runx-2 and osteocalcin signals indicating expansion of osteoprogenitors at the injury site as evaluated by qPCR and immunohistochemical localization. It was observed that med promoted bone regeneration by activating canonical Wnt and notch signaling pathway. This was evident by increased transcript and protein levels of Wnt and notch signaling components in the defect region. Finally, we confirmed that med treatment leads to elevated bone healing in pre-osteoblasts by co localization of beta catenin with osteoblast marker alkaline phosphatase. In conclusion, med treatment promotes new bone regeneration and healing at the injury site by activating Wnt/canonical and notch signaling pathways. This study also forms a strong case for evaluation of med in delayed union and non-union fracture cases.
Finite element analysis of unicompartmental knee arthroplasty.
Hopkins, Andrew R; New, Andrew M; Rodriguez-y-Baena, Ferdinando; Taylor, Mark
2010-01-01
Concerns over accelerated damage to the untreated compartment of the knee following unicompartmental knee arthroplasty (UKA), as well as the relatively poor success rates observed for lateral as opposed to the medial arthroplasty, remain issues for attention. Finite element analysis (FEA) was used to assess changes to the kinematics and potential for cartilage damage across the knee joint in response to the implantation of the Oxford Mobile Bearing UKA. FE models of lateral and medial compartment arthroplasty were developed, in addition to a healthy natural knee model, to gauge changes incurred through the arthroplasty. Varus-valgus misalignments were introduced to the femoral components to simulate surgical inaccuracy or over-correction. Boundary conditions from the Stanmore knee simulator during the stance phase of level gait were used. AP translations of the tibia in the medial UKA models were comparable to the behaviour of the natural knee models (+/-0.6mm deviation from pre-operative motion). Following lateral UKA, 4.1mm additional posterior translation of the tibia was recorded than predicted for the natural knee. IE rotations of the medial UKA models were less consistent with the pre-operative knee model than the lateral UKA models (7.7 degrees vs. 3.6 degrees deviation). Varus misalignment of the femoral prosthesis was more influential than valgus for medial UKA kinematics, whereas in lateral UKA, a valgus misalignment of the femoral prosthesis was most influential on the kinematics. Resection of the cartilage in the medial compartment reduced the overall risk of progressive OA in the knee, whereas removing the cartilage from the lateral compartment, and in particular introducing a valgus femoral misalignment, increased the overall risk of progressive OA in the knee. Based on these results, under the conditions tested herein, both medial and lateral UKA can be said to induce kinematics of the knee which could be considered broadly comparable to those of the natural knee, and that even a 10 degrees varus-valgus misalignment of the femoral component may not induce highly irregular kinematics. However, elevated posterior translation of the tibia in lateral UKA and large excursions of the insert may explain the higher incidence of bearing dislocation observed in some clinical studies. (c) 2009 IPEM. All rights reserved.
The tolerance of the femoral shaft in combined axial compression and bending loading.
Ivarsson, B Johan; Genovese, Daniel; Crandall, Jeff R; Bolton, James R; Untaroiu, Costin D; Bose, Dipan
2009-11-01
The likelihood of a front seat occupant sustaining a femoral shaft fracture in a frontal crash has traditionally been assessed by an injury criterion relying solely on the axial force in the femur. However, recently published analyses of real world data indicate that femoral shaft fracture occurs at axial loads levels below those found experimentally. One hypothesis attempting to explain this discrepancy suggests that femoral shaft fracture tends to occur as a result of combined axial compression and applied bending. The current study aims to evaluate this hypothesis by investigating how these two loading components interact. Femoral shafts harvested from human cadavers were loaded to failure in axial compression, sagittal plane bending, and combined axial compression and sagittal plane bending. All specimens subjected to bending and combined loading fractured midshaft, whereas the specimens loaded in axial compression demonstrated a variety of failure locations including midshaft and distal end. The interaction between the recorded levels of applied moment and axial compression force at fracture were evaluated using two different analysis methods: fitting of an analytical model to the experimental data and multiple regression analysis. The two analysis methods yielded very similar relationships between applied moment and axial compression force at midshaft fracture. The results indicate that posteroanterior bending reduces the tolerance of the femoral shaft to axial compression and that that this type of combined loading therefore may contribute to the high prevalence of femoral shaft fracture in frontal crashes.
Jenkins, Paul J; Ramaesh, Rishikesan; Pankaj, Pankaj; Patton, James T; Howie, Colin R; Goffin, Jérôme M; Merwe, Andrew van der; Wallace, Robert J; Porter, Daniel E; Simpson, A Hamish
2013-10-01
The micro-architecture of bone has been increasingly recognized as an important determinant of bone strength. Successful operative stabilization of fractures depends on bone strength. We evaluated the osseous micro-architecture and strength of the osteoporotic human femoral head. 6 femoral heads, obtained during arthroplasty surgery for femoral neck fracture, underwent micro-computed tomography (microCT) scanning at 30 μm, and bone volume ratio (BV/TV), trabecular thickness, structural model index, connection density, and degree of anisotropy for volumes of interest throughout the head were derived. A further 15 femoral heads underwent mechanical testing of compressive failure stress of cubes of trabecular bone from different regions of the head. The greatest density and trabecular thickness was found in the central core that extended from the medial calcar to the physeal scar. This region also correlated with the greatest degree of anisotropy and proportion of plate-like trabeculae. In the epiphyseal region, the trabeculae were organized radially from the physeal scar. The weakest area was found at the apex and peripheral areas of the head. The strongest region was at the center of the head. The center of the femoral head contained the strongest trabecular bone, with the thickest, most dense trabeculae. The apical region was weaker. From an anatomical and mechanical point of view, implants that achieve fixation in or below this central core may achieve the most stable fixation during fracture healing.
Quantitative Comparison of the Microscopic Anatomy of the Human ACL Femoral and Tibial Entheses
Beaulieu, Mélanie L.; Carey, Grace E.; Schlecht, Stephen H.; Wojtys, Edward M.; Ashton-Miller, James A.
2015-01-01
The femoral enthesis of the human anterior cruciate ligament (ACL) is known to be more susceptible to injury than the tibial enthesis. To determine whether anatomic differences might help explain this difference, we quantified the microscopic appearance of both entheses in 15 unembalmed knee specimens using light microscopy, toluidine blue stain and image analysis. The amount of calcified fibrocartilage and uncalcified fibrocartilage, and the ligament entheseal attachment angle were then compared between the femoral and tibial entheses via linear mixed-effects models. The results showed marked differences in anatomy between the two entheses. The femoral enthesis exhibited a 3.9-fold more acute ligament attachment angle than the tibial enthesis (p < 0.001), a 43% greater calcified fibrocartilage tissue area (p < 0.001), and a 226% greater uncalcified fibrocartilage depth (p < 0.001), with the latter differences being particularly pronounced in the central region. We conclude that the ACL femoral enthesis has more fibrocartilage and a more acute ligament attachment angle than the tibial enthesis, which provides insight into why it is more vulnerable to failure. PMID:26134706
Zheng, Zhong; Yin, Wei; Zara, Janette N.; Li, Weiming; Kwak, Jinny; Mamidi, Rachna; Lee, Min; Siu, Ronald K.; Ngo, Richard; Wang, Joyce; Carpenter, Doug; Zhang, Xinli; Wu, Benjamin; Ting, Kang; Soo, Chia
2010-01-01
Healing of contaminated/infected bone defects is a significant clinical challenge. Prevalence of multi-antibiotic resistant organisms has renewed interest in the use of antiseptic silver as an effective, but less toxic antimicrobial with decreased potential for bacterial resistance. In this study, we demonstrated that metallic nanosilver particles (with a size of 20–40 nm)-poly(lactic-co-glycolic acid) (PLGA) composite grafts have strong antibacterial properties. In addition, nanosilver particles-PLGA composite grafts did not inhibit adherence, proliferation, alkaline phosphatase activity, or mineralization of ongrowth MC3T3-E1 pre-osteoblasts compared to PLGA controls. Furthermore, nanosilver particles did not affect the osteoinductivity of bone morphogenetic protein 2 (BMP-2). Infected femoral defects implanted with BMP-2 coupled 2.0% nanosilver particles-PLGA composite grafts healed in 12 weeks without evidence of residual bacteria. In contrast, BMP-2 coupled PLGA control grafts failed to heal in the presence of continued bacterial colonies. Our results indicate that nanosilver of defined particle size is bactericidal without discernable in vitro and in vivo cytotoxicity or negative effects on BMP-2 osteoinductivity, making it an ideal antimicrobial for bone regeneration in infected wounds. PMID:20864167
Tibiotalar nonunion corrected by hindfoot arthrodesis.
Giza, Eric; Sarcon, Annahita K; Kreulen, Christopher
2010-04-01
A 65-year-old man without significant comorbidities was referred to the senior author (EG) 9 months after an ankle arthrodesis procedure with complaints of pain, swelling, and progressive hindfoot valgus. The patient had elected to have the index surgery because of severe ankle arthritis due to longstanding lateral ankle instability. Physical examination revealed a well-healed anterior, midline ankle incision with normal pulses and sensation. Painful, limited ankle and subtalar range of motion was noted along with 20 degrees of hindfoot valgus and subfibular impingement. Radiographs of the ankle revealed an attempted ankle fusion using a knee arthroplasty trabecular metal augment placed vertically at the tibiotalar joint. There were no screws or other hardware present to provide compression and stability of the fusion. A computed tomography scan showed a tibiotalar nonunion, erosion of the talar body, and severe tibiotalar and subtalar arthritis. Inflammatory markers were within normal range. Based on the findings of a failed fusion and progressive painful hindfoot deformity, it was determined that the patient would benefit from removal of the hardware and revision fusion surgery. Tibiotalocalcaneal (TTC) hindfoot fusion was planned because of the patient's talar collapse and tibiotalar/ subtalar arthritis. The TTC procedure was performed with a retrograde intramedullary nail, femoral head allograft, and morselized fibular autograft enriched with platelet-rich plasma. The femoral head was used as a structural allograft to fill the large bone defect, prevent limb shortening, and assist in correction of the hindfoot deformity. Intraoperative findings revealed severe metallic synovitis of the ankle and subtalar joints, metal debris at the site of the trabecular implant, and segmental defects of the distal tibia and talus. Weight bearing was permitted after 16 weeks when evidence of successful ankle fusion was confirmed radiographically. At 24 months, the patient was pain free and ambulating without difficulty.
Ke, Dongxu; Robertson, Samuel F; Dernell, William S; Bandyopadhyay, Amit; Bose, Susmita
2017-08-09
Plasma-sprayed hydroxyapatite (HA)-coated titanium implants have been widely used in orthopedic applications due to their inheritance of an excellent mechanical property from titanium and great osteoconductivity from HA. However, the lack of osteoinductivity limits their further applications. In this study, 1 wt % MgO and 0.5 wt % SiO 2 were mixed with HA for making plasma-sprayed coatings on titanium implants. Plasma-sprayed HA- and MgO/SiO 2 -HA-coated titanium implants showed adhesive bond strengths of 25.73 ± 1.92 and 23.44 ± 2.89 MPa, respectively. The presence of MgO and SiO 2 significantly increased the osteogenesis, osseointegration, and bone mineralization of HA-coated titanium implants by the evaluation of their histomorphology after 6, 10, and 14 weeks of implantation in rat distal femoral defects. Implant pushout tests also showed a shear modulus of 149.83 ± 3.69 MPa for MgO/SiO 2 -HA-coated implants after 14 weeks of implantation, compared to 52.68 ± 10.41 MPa for uncoated implants and 83.92 ± 3.68 MPa for pure HA-coated implants; These are differences in the shear modulus of 96% and 56.4%, respectively. This study assesses for the first time the quality of the bone-implant interface of induction plasma-sprayed MgO and SiO 2 binary-doped HA coatings on load-bearing implants compared to bare titanium and pure HA coatings in a quantitative manner. Relating the osseointegration and interface shear modulus to the quality of implant fixation is critical to the advancement and implementation of HA-coated orthopedic implants.
Microstructures and properties of cancellous bone of avascular necrosis of femoral heads
NASA Astrophysics Data System (ADS)
Yao, Xuefeng; Wang, Peng; Dai, Ruchun; Yeh, Hsien Yang
2010-03-01
The aim of this study is to investigate microscopic structure and characterize cancellous bone of avascular necrosis of the femoral head (ANFH). The rabbit model of the ANFH is established. The histopathologic features are studied successfully. The differences between the steroid-injection group (S.G.) and the controlled group (C.G.) are examined, including the weight of rabbits, the hematological examination and the three-dimensional structures. It is found that the plasma levels of cholesterol (CHO), high-density lipoprotein (HDL) and low-density lipoprotein (LDL) in S.G. are lower than those in C.G. when the triglyceride (TG) increased in the S.G.; but the bone mineral content (BMC) and the structural model index (SMI) of the organ and tissue decreased significantly in S.G. Three-dimensional structures of the femoral head are obtained using micro-computed tomography (CT) scanning and the mechanical model is established to analyze the influences of these structural changes on the mechanical properties of the cancellous bone.
Atzori, F; Sabatini, L; Deledda, D; Schirò, M; Lo Baido, R; Baido, R L; Massè, A
2015-04-01
Total knee arthroplasty gives excellent objective results. Nevertheless, the subjective findings do not match the normal knee perception: Often, it depends on patellar pain onset. In this study, we analyzed clinical and radiological items that can affect resurfaced patellar tracking, and role of a patella-friendly femoral component and patellar size on patellar pain onset. Thirty consecutive patients were implanted using the same-cemented posterior-stabilized TKA associated with patella resurfacing. Fifteen patients were implanted using a classical femoral component, while another 15 patients were implanted using a patella-friendly femoral component. The statistical analysis was set to detect a significant difference (p < 0.05) in clinical and radiological outcomes related to several surgical parameters. Clinical and functional outcomes were recorded using the Knee Society Scoring System (KSS) and patellar pain with the Burnett questionnaire. Mean follow-up was 25 months. KSS results were excellent in both groups. Group 2 (patella-friendly femoral model) reached a higher percentage of 100 points in the clinical and functional KSS, but there was no statistical difference. Also, no statistical differences for Burnett Questionnaire results were recorded. We had one case of patellar clunk syndrome in the standard femoral component group and one poor result in the second group. Postoperative radiographic measurements evidenced no statistical differences in both groups. In group 1 (classical femoral component), better significant result (p < 0.05) war recorded at clinical evaluation according to the Knee Society Scoring System (KSS) in case of wider patellar component resurfaced. The present study reveals no statistically significant difference in the incidence of anterior knee pain between classical and "patella-friendly" femoral components. With the particular type of implant design utilized in this study, when the classical femoral component is used, bigger patellar implant sizes (38 and 41 mm) showed superior clinical outcome.
Sim, Jae-Ang; Kim, Jong-Min; Lee, Sahnghoon; Bae, Ji-Yong; Seon, Jong-Keun
2017-04-01
Although trans-portal and outside-in techniques are commonly used for anatomical ACL reconstruction, there is very little information on variability in tunnel placement between two techniques. A total of 103 patients who received ACL reconstruction using trans-portal (50 patients) and outside-in techniques (53 patients) were included in the study. The ACL tunnel location, length and graft-femoral tunnel angle were analyzed using the 3D CT knee models, and we compared the location and length of the femoral and tibial tunnels, and graft bending angle between the two techniques. The variability in each technique regarding the tunnel location, length and graft tunnel angle using the range values was also compared. There were no differences in the average of femoral tunnel depth and height between the two groups. The ranges of femoral tunnel depth and height showed no difference between two groups (36 and 41 % in trans-portal technique vs. 32 and 41 % in outside-in technique). The average value and ranges of tibial tunnel location also showed similar results in two groups. The outside-in technique showed longer femoral tunnel than the trans-portal technique (34.0 vs. 36.8 mm, p = 0.001). The range of femoral tunnel was also wider in trans-portal technique than in outside-in technique. Although the outside-in technique showed significant acute graft bending angle than trans-portal technique in average values, the trans-portal technique showed wider ranges in graft bending angle than outside-in technique [ranges 73° (SD 13.6) vs. 53° (SD 10.7), respectively]. Although both trans-portal and outside-in techniques in ACL reconstruction can provide relatively consistent in femoral and tibial tunnel locations, trans-portal technique showed high variability in femoral tunnel length and graft bending angles than outside-in technique. Therefore, the outside-in technique in ACL reconstruction is considered as the effective method for surgeons to make more consistent femoral tunnel. III.
Pascual-Garrido, Cecilia; Daley, Erika; Verma, Nikhil N; Cole, Brian J
2017-02-01
To compare the results of focal metallic resurfacing with biologic procedures in patients more than 35 years of age with isolated, full thickness defects of the femoral condyle. A total of 61 patients met the selection criteria resulting in 30 patients treated with biological procedures, including debridement, microfracture, osteochondral autograft transplantation, osteochondral allograft, and autologous chondrocyte implantation (BIO group), and 32 patients treated with focal metallic resurfacing (CAP group). The BIO and CAP groups were matched according to treatment location, defect grade and size, and age profile. Outcomes included Western Ontario and McMaster Osteoarthritis Index (WOMAC), Short Form-12, and satisfaction. The primary combination endpoint was determined as a 20% improvement (minimum clinically important difference-20) on WOMAC pain and function at 2 years and no additional index lesion-related surgical intervention. Safety and effectiveness were also reported. Thirty patients in the BIO group (mean age of 44.6, range 35-64) had an average follow-up of 2.6 years and 32 patients in the CAP group (mean age 47.9, range 37-68) were followed for 2.0 years. Fifty-three percent in the BIO group and 75% in the CAP group achieved success per the endpoint definition. The mean total WOMAC score improved significantly for both groups (BIO: 57-78; P < .001) (CAP: 41-86; P < .001). The physical component score (Short Form-12 PCS) improved significantly in the CAP group only (30-36.4; P < .001). Good to excellent patient satisfaction was achieved by 80% in BIO and 91% in CAP. There were 4 secondary procedures on the index lesion in the BIO group and 2 in the CAP group. Careful patient selection can achieve high satisfaction rates with both biological and focal metal resurfacing procedures for the treatment of isolated focal chondral lesions of the femoral condyle in the knee. Focal metallic resurfacing results in similar clinical outcomes and provides excellent success rates at short-term follow-up. Level III comparative study. Copyright © 2016. Published by Elsevier Inc.
Cao, Lei; Li, Xiaokang; Zhou, Xiaoshu; Li, Yong; Vecchio, Kenneth S; Yang, Lina; Cui, Wei; Yang, Rui; Zhu, Yue; Guo, Zheng; Zhang, Xing
2017-03-22
Sea urchin spines (Heterocentrotus mammillatus), with a hierarchical open-cell structure similar to that of human trabecular bone and superior mechanical property (compressive strength ∼43.4 MPa) suitable for machining to shape, were explored for potential applications of bone defect repair. Finite element analyses reveal that the compressive stress concentrates along the dense growth rings and dissipates through strut structures of the stereoms, indicating that the exquisite mesostructures play an important role in high strength-to-weight ratios. The fracture strength of magnesium-substituted tricalcium phosphate (β-TCMP) scaffolds produced by hydrothermal conversion of urchin spines is about 9.3 MPa, comparable to that of human trabecular bone. New bone forms along outer surfaces of β-TCMP scaffolds after implantation in rabbit femoral defects for one month and grows into the majority of the inner open-cell spaces postoperation in three months, showing tight interface between the scaffold and regenerative bone tissue. Fusion of beagle lumbar facet joints using a Ti-6Al-4V cage and β-TCMP scaffold can be completed within seven months with obvious biodegradation of the β-TCMP scaffold, which is nearly completely degraded and replaced by newly formed bone ten months after implantation. Thus, sea urchin spines suitable for machining to shape have advantages for production of biodegradable artificial grafts for bone defect repair.
Osteopenia as a feature of the androgen insensitivity syndrome.
Soule, S G; Conway, G; Prelevic, G M; Prentice, M; Ginsburg, J; Jacobs, H S
1995-12-01
The syndrome of androgen insensitivity, a paradigm of a hormone resistance syndrome, manifests as failure of masculinization despite normal or high concentrations of serum testosterone. The defect in these 46 XY patients resides in the androgen receptor gene, with consequent defective androgen action and abnormal sexual differentiation. We sought to evaluate whether the adverse sequelae of androgen resistance may extend to skeletal tissue by measuring bone mineral density in six patients with androgen insensitivity. A cross-sectional retrospective study. Bone mineral density was measured by means of a Dexa (Hologic QDR 1000 scanner). The diagnosis of androgen insensitivity was confirmed in each patient by karyotype and assay of sex hormones. The five adult patients with androgen insensitivity had been exposed to both defective androgen action and variable periods of oestrogen deficiency. The latter resulted from the low circulating oestrogen concentrations (for premenopausal females) before gonadectomy and inadequate oestrogen replacement after gonadectomy. All five adults with androgen insensitivity had osteopenia in both the lumbar spine (T-score -1.52 to -3.85) and femoral neck (T-score -1.34 to -4.91). Osteopenia in patients with androgen insensitivity may relate to defective androgen action, oestrogen deficiency or a combination of the two. These observations have implications for the management of patients with androgen insensitivity and may provide insight into the effects of androgens on the female as well as the male skeleton.
Chou, Ying-Chao; Lee, Demei; Chang, Tzu-Min; Hsu, Yung-Heng; Yu, Yi-Hsun; Liu, Shih-Jung; Ueng, Steve Wen-Neng
2016-04-20
This study aimed to develop a new biodegradable polymeric cage to convert corticocancellous bone chips into a structured strut graft for treating segmental bone defects. A total of 24 adult New Zealand white rabbits underwent a left femoral segmental bone defect creation. Twelve rabbits in group A underwent three-dimensional (3D) printed cage insertion, corticocancellous chips implantation, and Kirschner-wire (K-wire) fixation, while the other 12 rabbits in group B received bone chips implantation and K-wire fixation only. All rabbits received a one-week activity assessment and the initial image study at postoperative 1 week. The final image study was repeated at postoperative 12 or 24 weeks before the rabbit scarification procedure on schedule. After the animals were sacrificed, both femurs of all the rabbits were prepared for leg length ratios and 3-point bending tests. The rabbits in group A showed an increase of activities during the first week postoperatively and decreased anterior cortical disruptions in the postoperative image assessments. Additionally, higher leg length ratios and 3-point bending strengths demonstrated improved final bony ingrowths within the bone defects for rabbits in group A. In conclusion, through this bone graft converting technique, orthopedic surgeons can treat segmental bone defects by using bone chips but with imitate characters of structured cortical bone graft.
Chou, Ying-Chao; Lee, Demei; Chang, Tzu-Min; Hsu, Yung-Heng; Yu, Yi-Hsun; Liu, Shih-Jung; Ueng, Steve Wen-Neng
2016-01-01
This study aimed to develop a new biodegradable polymeric cage to convert corticocancellous bone chips into a structured strut graft for treating segmental bone defects. A total of 24 adult New Zealand white rabbits underwent a left femoral segmental bone defect creation. Twelve rabbits in group A underwent three-dimensional (3D) printed cage insertion, corticocancellous chips implantation, and Kirschner-wire (K-wire) fixation, while the other 12 rabbits in group B received bone chips implantation and K-wire fixation only. All rabbits received a one-week activity assessment and the initial image study at postoperative 1 week. The final image study was repeated at postoperative 12 or 24 weeks before the rabbit scarification procedure on schedule. After the animals were sacrificed, both femurs of all the rabbits were prepared for leg length ratios and 3-point bending tests. The rabbits in group A showed an increase of activities during the first week postoperatively and decreased anterior cortical disruptions in the postoperative image assessments. Additionally, higher leg length ratios and 3-point bending strengths demonstrated improved final bony ingrowths within the bone defects for rabbits in group A. In conclusion, through this bone graft converting technique, orthopedic surgeons can treat segmental bone defects by using bone chips but with imitate characters of structured cortical bone graft. PMID:27104525
Harada, Yohei; Nakasa, Tomoyuki; Mahmoud, Elhussein Elbadry; Kamei, Goki; Adachi, Nobuo; Deie, Masataka; Ochi, Mitsuo
2015-10-01
The present study investigated intra-articular injection of bone-marrow-derived mesenchymal stem cells (MSCs) combined with articulated joint distraction as treatment for osteochondral defects. Large osteochondral defects were created in the weight-bearing area of the medial femoral condyle in rabbit knees. Four weeks after defect creation, rabbits were divided into six groups: control group, MSC group, distraction group, distraction + MSC group, temporary distraction group, and temporary distraction + MSC group. Groups with MSC received intra-articular injection of MSCs. Groups with distraction underwent articulated distraction arthroplasty. Groups with temporary distraction discontinued the distraction after 4 weeks. The rabbits were euthanized at 4, 8, and 12 weeks after treatment except temporary distraction groups which were euthanized at only 12 weeks. Histological scores in the distraction + MSC group were significantly better than in the control, MSC group or distraction group at 4 and 8 weeks, but showed no further improvement. At 12 weeks, the temporary distraction + MSC group showed the best results, demonstrating hyaline cartilage repair with regeneration of the osteochondral junction. In conclusion, joint distraction with intra-articular injection of MSCs promotes early cartilage repair, and compressive loading of the repair tissue after temporary distraction stimulates articular cartilage regeneration. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Tribological changes in the articular cartilage of a human femoral head with avascular necrosis.
Seo, Eun-Min; Shrestha, Suman K; Duong, Cong-Truyen; Sharma, Ashish Ranjan; Kim, Tae-Woo; Vijayachandra, Ayyappan; Thompson, Mark S; Cho, Myung Guk; Park, Sungchan; Kim, Kwanghoon; Park, Seonghun; Lee, Sang-Soo
2015-06-29
The present study evaluated the tribological properties of the articular cartilage surface of the human femoral head with postcollapse stage avascular necrosis (AVN) using atomic force microscopy. The cartilage surface in the postcollapse stage AVN of the femoral head was reported to resemble those of disuse conditions, which suggests that the damage could be reversible and offers the possibilities of success of head-sparing surgeries. By comparing the tribological properties of articular cartilage in AVN with that of osteoarthritis, the authors intended to understand the cartilage degeneration mechanism and reversibility of AVN. Human femoral heads with AVN were explanted from the hip replacement surgery of four patients (60-83 years old). Nine cylindrical cartilage samples (diameter, 5 mm and height, 0.5 mm) were sectioned from the weight-bearing areas of the femoral head with AVN, and the cartilage surface was classified according to the Outerbridge Classification System (AVN0, normal; AVN1, softening and swelling; and AVN2, partial thickness defect and fissuring). Tribological properties including surface roughness and frictional coefficients and histochemistry including Safranin O and lubricin staining were compared among the three groups. The mean surface roughness Rq values of AVN cartilage increased significantly with increasing Outerbridge stages: Rq = 137 ± 26 nm in AVN0, Rq = 274 ± 49 nm in AVN1, and Rq = 452 ± 77 nm in AVN2. Significant differences in Rq were observed among different Outerbridge stages in all cases (p < 0.0001). The frictional coefficients (μ) also increased with increasing Outerbridge stages. The frictional coefficient values were μ = 0.115 ± 0.034 in AVN0, μ = 0.143 ± 0.025 in AVN1, and μ = 0.171 ± 0.039 in AVN2. Similarly to the statistical analysis of surface roughness, significant statistical differences were detected between different Outerbridge stages in all cases (p < 0.05). Both surface roughness and frictional coefficient of cartilage, which were linearly correlated, increased with increasing Outerbridge stages in postcollapse AVN. The underlying mechanism of these results can be related to proteoglycan loss within the articular cartilage that is also observed in osteoarthritis. With regard to the tribological properties, the cartilage degeneration mechanism in AVN was similar to that of osteoarthritis without reversibility.
Effects of Proud Large Osteochondral Plugs on Contact Forces and Knee Kinematics: A Robotic Study.
Du, Peter Z; Markolf, Keith L; Boguszewski, Daniel V; Yamaguchi, Kent T; Lama, Christopher J; McAllister, David R; Jones, Kristofer J
2018-05-01
Osteochondral allograft (OCA) transplantation is used to treat large focal femoral condylar articular cartilage defects. A proud plug could affect graft survival by altering contact forces (CFs) and knee kinematics. A proud OCA plug will significantly increase CF and significantly alter knee kinematics throughout controlled knee flexion. Controlled laboratory study. Human cadaver knees had miniature load cells, each with a 20-mm-diameter cylinder of native bone/cartilage attached at its exact anatomic position, installed in both femoral condyles at standardized locations representative of clinical defects. Spacers were inserted to create proud plug conditions of +0.5, +1.0, and +1.5 mm. CFs and knee kinematics were recorded as a robot flexed the knee continuously from 0° to 50° under 1000 N of tibiofemoral compression. CFs were increased significantly (vs flush) for all proudness conditions between 0° and 45° of flexion (medial) and 0° to 50° of flexion (lateral). At 20°, the average increases in medial CF for +0.5-mm, +1-mm, and +1.5-mm proudness were +80 N (+36%), +155 N (+70%), and +193 N (+87%), respectively. Corresponding increases with proud lateral plugs were +44 N (+14%), +90 N (+29%), and +118 N (+38%). CF increases for medial plugs at 20° of flexion were significantly greater than those for lateral plugs at all proudness conditions. At 50°, a 1-mm proud lateral plug significantly decreased internal tibial rotation by 15.4° and decreased valgus rotation by 2.5°. A proud medial or lateral plug significantly increased CF between 0° and 45° of flexion. Our results suggest that a medial plug at 20° may be more sensitive to graft incongruity than a lateral plug. The changes in rotational kinematics with proud lateral plugs were attributed to earlier contact between the proud plug's surface and the lateral meniscus, leading to rim impingement with decreased tibial rotation. Increased CF and altered knee kinematics from a proud femoral plug could affect graft viability. Plug proudness of only 0.5 mm produced significant changes in CF and knee kinematics, and the clinically accepted 1-mm tolerance may need to be reexamined in view of our findings.
[Groin abscesses and vascular catastrophes in intravenous drug users--strategy and results].
Scheuerlein, H; Ruff, S; Haage, P; Zirngibl, H; Fraunhofer, S; Settmacher, U
2008-02-01
Drug addiction is a global medical and public health-care problem. Infections of the groin and fossa cubitalis are a common clinical problem in these patients. Severe vascular complications are rare but if they occur, therapy is difficult and requires emergency management and surgery because of bleeding problems. In a retrospective case series, we report on patients treated within an emergency setting in our hospital because of groin abscesses with vascular involvement between 2003 and 2006. The therapeutic concepts and results are reported and discussed in the context of a review of the international literature. We report on 4 patients with a long-standing history of i. v. drug abuse (average age 33, range 29-36 years). All were hepatitis C Ag positive and HIV negative. The general health and nutritional status were not compromised, all patients had one or more DVT in their medical history. In two cases, emergency surgery with revascularisation was necessary (after 2 days in one case and 4 weeks in the other) because of septic bleeding subsequent to abscess incision. Two patients underwent primary revascularisation because of pseudoaneurysms. The grafts were a saphenous vein patch and a superficial femoral artery patch in one and deep vein segments in two cases. In two cases, a sartorius muscle flap and VAC therapy were used to cover the defect. All patients survived, minor amputation became necessary in one case. Abscess excision and debridement have to be as complete as possible and primary revascularisation is the procedure of choice in cases of severe groin infection. In the case of large vessel involvement, abscess incision alone without revision of the vascular structures is dangerous because of subsequent complications like secondary ruptures. For this reason, these patients require intensive care and close monitoring. Successful treatment exclusively based on ligation is described in literature with regard to isolated lesions of the superficial or deep femoral artery. Because of the very common involvement of the femoral bifurcation, revascularisation is, however, necessary in most cases and should be performed with autologous grafts if possible. If complete covering of the defect is not possible, a sartorius muscle flap is a good choice. Primary wound closure can be problematic because of recurrences, therefore vacuum-assisted wound closure is a valuable addition to the overall therapeutic approach in these cases.
Model-based Roentgen stereophotogrammetry of orthopaedic implants.
Valstar, E R; de Jong, F W; Vrooman, H A; Rozing, P M; Reiber, J H
2001-06-01
Attaching tantalum markers to prostheses for Roentgen stereophotogrammetry (RSA) may be difficult and is sometimes even impossible. In this study, a model-based RSA method that avoids the attachment of markers to prostheses is presented and validated. This model-based RSA method uses a triangulated surface model of the implant. A projected contour of this model is calculated and this calculated model contour is matched onto the detected contour of the actual implant in the RSA radiograph. The difference between the two contours is minimized by variation of the position and orientation of the model. When a minimal difference between the contours is found, an optimal position and orientation of the model has been obtained. The method was validated by means of a phantom experiment. Three prosthesis components were used in this experiment: the femoral and tibial component of an Interax total knee prosthesis (Stryker Howmedica Osteonics Corp., Rutherfort, USA) and the femoral component of a Profix total knee prosthesis (Smith & Nephew, Memphis, USA). For the prosthesis components used in this study, the accuracy of the model-based method is lower than the accuracy of traditional RSA. For the Interax femoral and tibial components, significant dimensional tolerances were found that were probably caused by the casting process and manual polishing of the components surfaces. The largest standard deviation for any translation was 0.19mm and for any rotation it was 0.52 degrees. For the Profix femoral component that had no large dimensional tolerances, the largest standard deviation for any translation was 0.22mm and for any rotation it was 0.22 degrees. From this study we may conclude that the accuracy of the current model-based RSA method is sensitive to dimensional tolerances of the implant. Research is now being conducted to make model-based RSA less sensitive to dimensional tolerances and thereby improving its accuracy.
Hernández-Cortés, Pedro; Galindo-Moreno, Pablo; Catena, Andrés; Ortega-Oller, Inmaculada; Salas-Pérez, José; Gómez-Sánchez, Rafael; Aguilar, Mariano; Aguilar, David
2014-01-01
Objective. This study was designed to explore relationships of resonance frequency analysis (RFA)—assessed implant stability (ISQ values) with bone morphometric parameters and bone quality in an ex vivo model of dental implants placed in human femoral heads and to evaluate the usefulness of this model for dental implant studies. Material and Methods. This ex vivo study included femoral heads from 17 patients undergoing surgery for femoral neck fracture due to osteoporosis (OP) (n = 7) or for total prosthesis joint replacement due to severe hip osteoarthrosis (OA) (n = 10). Sixty 4.5 × 13 mm Dentsply Astra implants were placed, followed by RFA. CD44 immunohistochemical analysis for osteocytes was also carried out. Results. As expected, the analysis yielded significant effects of femoral head type (OA versus OA) (P < 0.001), but not of the implants (P = 0.455) or of the interaction of the two factors (P = 0.848). Bonferroni post hoc comparisons showed a lower mean ISQ for implants in decalcified (50.33 ± 2.92) heads than in fresh (66.93 ± 1.10) or fixated (70.77 ± 1.32) heads (both P < 0.001). The ISQ score (fresh) was significantly higher for those in OA (73.52 ± 1.92) versus OP (67.13 ± 1.09) heads. However, mixed linear analysis showed no significant association between ISQ scores and morphologic or histomorphometric results (P > 0.5 in all cases), and no significant differences in ISQ values were found as a function of the length or area of the cortical layer (both P > 0.08). Conclusion. Although RFA-determined ISQ values are not correlated with morphometric parameters, they can discriminate bone quality (OP versus OA). This ex vivo model is useful for dental implant studies. PMID:24995307
Bone repair using a new injectable self-crosslinkable bone substitute.
Fellah, Borhane H; Weiss, Pierre; Gauthier, Olivier; Rouillon, Thierry; Pilet, Paul; Daculsi, Guy; Layrolle, Pierre
2006-04-01
A new injectable and self-crosslinkable bone substitute (IBS2) was developed for filling bone defects. The IBS2 consisted of a chemically modified polymer solution mixed with biphasic calcium phosphate (BCP) ceramic particles. The polymer hydroxypropylmethyl cellulose was functionalized with silanol groups (Si-HPMC) and formed a viscous solution (3 wt %) in alkaline medium. With a decrease in pH, self-hardening occurred due to the formation of intermolecular -Si-O- bonds. During setting, BCP particles, 40 to 80 microm in diameter, were added to the polymer solution at a weight ratio of 50/50. The resulting injectable material was bilaterally implanted into critically sized bone defects at the distal femoral epiphyses of nine New Zealand White rabbits. The IBS2 filled the bone defects entirely and remained in place. After 8 weeks, bone had grown centripetally and progressed towards the center of the defects. Newly formed bone, ceramic, and nonmineralized tissue ratios were 24.6% +/- 5.6%, 21.6% +/- 5.8%, and 53.7% +/- 0.1%, respectively. Mineralized and mature bone was observed between and in contact with the BCP particles. The bone/ceramic apposition was 73.4% +/- 10.6%. The yield strength for the IBS2-filled defects was 16.4 +/- 7.2 MPa, significantly higher than for the host trabecular bone tissue (2.7 +/- 0.4 MPa). This study showed that BCP particles supported the bone healing process by osteoconduction while the Si-HPMC hydrogel created intergranular space for bone ingrowth. This new injectable and self-crosslinkable bone substitute could be used conveniently in orthopedic surgery for filling critical-size bone defects. Copyright 2006 Orthopaedic Research Society
Gasper, Warren J; Jimenez, Cynthia A; Walker, Joy; Conte, Michael S; Seward, Kirk; Owens, Christopher D
2013-12-01
Endovascular interventions on peripheral arteries are limited by high rates of restenosis. Our hypothesis was that adventitial injection of rapamycin nanoparticles would be safe and reduce luminal stenosis in a porcine femoral artery balloon angioplasty model. Eighteen juvenile male crossbred swine were included. Single-injury (40%-60% femoral artery balloon overstretch injury; n=2) and double-injury models (endothelial denudation injury 2 weeks before a 20%-30% overstretch injury; n=2) were compared. The double-injury model produced significantly more luminal stenosis at 28 days, P=0.002, and no difference in medial fibrosis or inflammation. Four pigs were randomized to the double-injury model and adventitial injection of saline (n=2) or 500 μg of nanoparticle albumin-bound rapamycin (nab-rapamycin; n=2) with an endovascular microinfusion catheter. There was 100% procedural success and no difference in endothelial regeneration. At 28 days, nab-rapamycin led to significant reductions in luminal stenosis, 17% (interquartile range, 12%-35%) versus 10% (interquartile range, 8.3%-14%), P=0.001, medial cell proliferation, P<0.001, and fibrosis, P<0.001. There were significantly fewer adventitial leukocytes at 3 days, P<0.001, but no difference at 28 days. Pharmacokinetic analysis (single-injury model) found rapamycin concentrations 1500× higher in perivascular tissues than in blood at 1 hour. Perivascular rapamycin persisted ≥8 days and was not detectable at 28 days. Adventitial nab-rapamycin injection was safe and significantly reduced luminal stenosis in a porcine femoral artery balloon angioplasty model. Observed reductions in early adventitial leukocyte infiltration and late medial cell proliferation and fibrosis suggest an immunosuppressive and antiproliferative mechanism. An intraluminal microinfusion catheter for adventitial injection represents an alternative to stent- or balloon-based local drug delivery.
Hip morphology predicts posterior hip impingement in a cadaveric model.
Morris, William Z; Fowers, Cody A; Weinberg, Douglas S; Millis, Michael B; Tu, Leigh-Anne; Liu, Raymond W
2018-05-01
Posterior hip impingement is a recently-identified cause of hip pain. The purpose of this study is to characterise posterior femoroacetabular and ischiofemoral impingement and identify its predisposing morphologic traits. Two hundred and six cadaveric hips were randomly selected and taken through controlled motion in two pure axes associated with posterior hip impingement: external rotation (through the mechanical axis) and adduction (coronal plane). The range of motion and location of impingement was noted for each specimen. Morphologic traits including femoral/acetabular version, and true neck-shaft angle (TNSA) were also measured. External rotation impingement occurred between the femoral neck and acetabulum in 83.0% of hips, and between the lesser trochanter and ischial tuberosity in 17.0%. Adduction impingement occurred between the lesser trochanter and ischial tuberosity in 78.6% of hips, and between the femoral neck and acetabulum in 21.4%. Multiple regression revealed that increased femoral/acetabular version predicted earlier external rotation and adduction impingement. Unstandardised betas ranging from -0.39 to -0.64 reflect that each degree of increased femoral/acetabular version individually accounts for a loss of external rotation or adduction of approximately half a degree before impingement ( p < 0.001 for each). Increased TNSA was associated with earlier adduction impingement only (unstandardised beta -0.35, p = 0.005). Relative femoral/acetabular anteversion was associated with earlier posterior hip impingement. Coxa valga was associated with earlier adduction impingement, but protective against external rotation impingement. These findings highlight the importance of monitoring correction during femoral/acetabular osteotomies, as overcorrection of retroversion may predispose to earlier posterior impingement.
Salikhov, Ramil Z.; Masgutov, Ruslan F.; Chekunov, Mikhail A.; Tazetdinova, Leysan G.; Masgutova, Galina; Teplov, Oleg V.; Galimov, Damir; Plakseichuk, Yuri; Yagudin, Ramil; Pankov, Igor O.; Rizvanov, Albert
2018-01-01
In this study we applied autologous fat tissue stromal vascular fraction (SVF) cells in combination with microfracturing technique in a 36-year-old man with an osteochondral lesion of the medial femoral condyle 8 months after the injury. Cell material was generated by fat tissue liposuction from the anterior abdominal wall with subsequent extraction of the SVF and injected through a mini-arthrotomy portal with subsequent fibrin sealant fixation. The follow-up period was 2 years. Clinical score improved from 23 to 96 according to IKDC and from 10 to 90 according to EQ-VAS at 24 months follow-up. Magnetic resonance imaging (MRI) before the surgery revealed an osteochondral lesion with development of significant trabecular edema that remained unchanged for 6 months despite conservative treatment. MRI 1 and 2 years after the surgery showed the recovery of the damaged cartilage thickness with somewhat uneven structure and a decrease in the trabecular edema of the femoral condyle. The use of SVF cells with fibrin sealant fixation might be a promising approach in the treatment of osteochondral joint lesions. Further studies are required. PMID:29900170
Kim, Yong Sun; Choi, Hyeong Ho; Cho, Young Nam; Park, Yong Jae; Lee, Jong B; Yang, King H; King, Albert I
2005-11-01
Although biomechanical studies on the knee-thigh-hip (KTH) complex have been extensive, interactions between the KTH and various vehicular interior design parameters in frontal automotive crashes for newer models have not been reported in the open literature to the best of our knowledge. A 3D finite element (FE) model of a 50(th) percentile male KTH complex, which includes explicit representations of the iliac wing, acetabulum, pubic rami, sacrum, articular cartilage, femoral head, femoral neck, femoral condyles, patella, and patella tendon, has been developed to simulate injuries such as fracture of the patella, femoral neck, acetabulum, and pubic rami of the KTH complex. Model results compared favorably against regional component test data including a three-point bending test of the femur, axial loading of the isolated knee-patella, axial loading of the KTH complex, axial loading of the femoral head, and lateral loading of the isolated pelvis. The model was further integrated into a Wayne State University upper torso model and validated against data obtained from whole body sled tests. The model was validated against these experimental data over a range of impact speeds, impactor masses and boundary conditions. Using Design Of Experiment (DOE) methods based on Taguchi's approach and the developed FE model of the whole body, including the KTH complex, eight vehicular interior design parameters, namely the load limiter force, seat belt elongation, pretensioner inlet amount, knee-knee bolster distance, knee bolster angle, knee bolster stiffness, toe board angle and impact speed, each with either two or three design levels, were simulated to predict their respective effects on the potential of KTH injury in frontal impacts. Simulation results proposed best design levels for vehicular interior design parameters to reduce the injury potential of the KTH complex due to frontal automotive crashes. This study is limited by the fact that prediction of bony fracture was based on an element elimination method available in the LS-DYNA code. No validation study was conducted to determine if this method is suitable when simulating fractures of biological tissues. More work is still needed to further validate the FE model of the KTH complex to increase its reliability in the assessment of various impact loading conditions associated with vehicular crash scenarios.
Whyte, Graeme P; McGee, Alan; Jazrawi, Laith; Meislin, Robert
2016-05-01
To evaluate the fixation integrity at time zero of a type I/III collagen patch secured to a chondral defect in the porcine knee using methods typically employed in autologous chondrocyte implantation (ACI) and matrix-assisted chondrocyte implantation. Twenty-four porcine knee specimens underwent a medial parapatellar arthrotomy. A prefabricated template was used to create cartilage defects of 2 cm(2) in the medial femoral condyle. A size-matched collagen patch was fashioned. Four methods of fixation to the chondral defect were analyzed: group 1-saline, group 2-fibrin glue around the periphery of the patch, group 3-fibrin glue applied to the base of the defect and around the periphery of the patch, group 4-6-0 vicryl suture and fibrin glue around the periphery of the patch. Collagen patch fixation was assessed at intervals of 60, 300, 600, 900, and 1,200 cycles from full extension to 90° of flexion, performed manually without application of axial force. Patch fixation was evaluated by 2 independent observers using a customized scoring scale. Mean peripheral detachment of the patch and chondral defect uncovering remained less than 25% for all groups. Area of defect uncovering was significantly increased in group 2 compared with group 4 after 900 and 1,200 cycles (P = .0014 and P = .0025, respectively). Fibrin glue applied to the base of the defect, or suturing of the patch, reduced deformation significantly after 900 cycles. Suture increases the stability of fixation of a type I/III collagen patch to a chondral defect better than fibrin glue alone in the porcine knee after repetitive cycling, with respect to patch detachment and chondral defect uncovering. Application of fibrin glue to the base of the defect, or securing the patch with suture, decreases collagen patch deformation. In cases where minimally invasive techniques do not allow suture fixation of the collagen patch, scaffold fixation may be compromised during articular motion protocols typically used after second- and third-generation ACI procedures. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Moreno-Jiménez, Inés; Hulsart-Billstrom, Gry; Lanham, Stuart A.; Janeczek, Agnieszka A.; Kontouli, Nasia; Kanczler, Janos M.; Evans, Nicholas D.; Oreffo, Richard Oc
2016-08-01
Biomaterial development for tissue engineering applications is rapidly increasing but necessitates efficacy and safety testing prior to clinical application. Current in vitro and in vivo models hold a number of limitations, including expense, lack of correlation between animal models and human outcomes and the need to perform invasive procedures on animals; hence requiring new predictive screening methods. In the present study we tested the hypothesis that the chick embryo chorioallantoic membrane (CAM) can be used as a bioreactor to culture and study the regeneration of human living bone. We extracted bone cylinders from human femoral heads, simulated an injury using a drill-hole defect, and implanted the bone on CAM or in vitro control-culture. Micro-computed tomography (μCT) was used to quantify the magnitude and location of bone volume changes followed by histological analyses to assess bone repair. CAM blood vessels were observed to infiltrate the human bone cylinder and maintain human cell viability. Histological evaluation revealed extensive extracellular matrix deposition in proximity to endochondral condensations (Sox9+) on the CAM-implanted bone cylinders, correlating with a significant increase in bone volume by μCT analysis (p < 0.01). This human-avian system offers a simple refinement model for animal research and a step towards a humanized in vivo model for tissue engineering.
Gil-Albarova, Jorge; Salinas, Antonio J; Bueno-Lozano, Antonio L; Román, Jesus; Aldini-Nicolo, Nicolo; García-Barea, Agustina; Giavaresi, Gianluca; Fini, Milena; Giardino, Roberto; Vallet-Regí, Maria
2005-07-01
The in vivo evaluation, in New Zealand rabbits, of a sol-gel glass 70% CaO-30% SiO2 (in mol%) and a glass-ceramic obtained from thermal treatment of the glass, both bioactive in Kokubo's simulated body fluid (SBF), is presented. Femoral bone diaphyseal critical defects were filled with: (i) sol-gel glass cylinders, (ii) glass-ceramic cylinders, or (iii) no material (control group). Osteosynthesis was done by means of anterior screwed plates with an associate intramedullar Kirschner wire. Each group included 10 mature rabbits, 9 months old. Follow-up was 6 months. After sacrifice, macroscopic study showed healing of bone defects, with bone coating over the cylinders, but without evidence of satisfactory repair in control group. Radiographic study showed good implant stability and periosteal growth and bone remodelling around and over the filled bone defect. The morphometric study showed minimum evidences of degradation or resorption in glass-ceramic cylinders, maintaining its original shape, but sol-gel glass cylinders showed abundant fragmentation and surface resorption. An intimate union of the new-formed bone to both materials was observed. Mechanical study showed the higher results in the glass-ceramic group, whereas sol-gel glass and control group showed no differences. The minimum degradation of glass-ceramic cylinders suggests their application in critical bone defects locations of transmission forces or load bearing. The performance of sol-gel glass cylinders suggests their usefulness in locations where a quick resorption should be preferable, considering the possibility of serving as drug or cells vehicle for both of them.
Martinez-Carranza, Nicolas; Hultenby, Kjell; Lagerstedt, Anne Sofie; Schupbach, Peter; Berg, Hans E
2017-07-01
Background Full-depth cartilage lesions do not heal and the long-term clinical outcome is uncertain. In the symptomatic middle-aged (35-60 years) patient, treatment with metal implants has been proposed. However, the cartilage health surrounding these implants has not been thoroughly studied. Our objective was to evaluate the health of cartilage opposing and adjacent to metal resurfacing implants. Methods The medial femoral condyle was operated in 9 sheep bilaterally. A metallic resurfacing metallic implant was immediately inserted into an artificially created 7.5 mm defect while on the contralateral knee the defect was left untreated. Euthanasia was performed at 6 months. Six animals, of similar age and study duration, from a previous study were used for comparison in the evaluation of cartilage health adjacent to the implant. Cartilage damage to joint surfaces within the knee, cartilage repair of the defect, and cartilage adjacent to the implant was evaluated macroscopically and microscopically. Results Six animals available for evaluation of cartilage health within the knee showed a varying degree of cartilage damage with no statistical difference between defects treated with implants or left untreated ( P = 0.51; 95% CI -3.7 to 6.5). The cartilage adjacent to the implant (score 0-14; where 14 indicates no damage) remained healthy in these 6 animals showing promising results (averaged 10.5; range 9-11.5, SD 0.95). Cartilage defects did not heal in any case. Conclusion Treatment of a critical size focal lesion with a metal implant is a viable alternative treatment.
Van Rompaey, Jason; Bowers, Greg; Radhakrishnan, Jay; Panizza, Benedict; Solares, C Arturo
2014-06-01
Injury to the internal carotid artery is a feared complication of endoscopic endonasal surgery of the skull base. Such an event, although rare, is associated with high morbidity and mortality. Even if bleeding is controlled, permanent neurological defects frequently persist. Many techniques have been developed to manage internal carotid artery rupture with varying degrees of success. The purpose of this study was to explore endoscopic management of arterial damage with endovascular closure devices used for a femoral arteriotomy. The ability to remotely suture a damaged artery permits the possible adaptation of this technology in managing endoscopic arterial complications. Technical note. After the creation of an endoscopic endonasal corridor in a cadaveric specimen, an arteriotomy was created at the cavernous portion of the internal carotid artery. The Angio-Seal, StarClose, and MynxGrip vascular closure devices were utilized under endoscopic guidance to repair the arteriotomy. Angiography was then done on a cadaver sutured with the StarClose. Both the Angio-Seal and StarClose were deployed quickly and appeared to provide sufficient closure of the arteriotomy. The Angio-Seal required the use of a guidewire and was longer to deploy when compared with the StarClose. The StarClose deployment was quick and facile. The MynxGrip also deployed without difficulty. The Angio-Seal and StarClose systems were both successfully deployed utilizing an endoscopic endonasal approach. The MynxGrip was the easiest to deploy and has the greatest potential to be of benefit in this application. Further studies with hemodynamic models are required to properly assess the appropriateness in this setting. NA. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
Precision of computer-assisted core decompression drilling of the femoral head.
Beckmann, J; Goetz, J; Baethis, H; Kalteis, T; Grifka, J; Perlick, L
2006-08-01
Osteonecrosis of the femoral head is a local destructive disease with progression into devastating stages. Left untreated it mostly leads to severe secondary osteoarthrosis and early endoprosthetic joint replacement. Core decompression by exact drilling into the ischemic areas can be performed in early stages according to Ficat or ARCO. Computer-aided surgery might enhance the precision of the drilling and lower the radiation exposure time of both staff and patients. The aim of this study was to evaluate the precision of the fluoroscopically based VectorVision navigation system in an in vitro model. Thirty sawbones were prepared with a defect filled up with a radiopaque gypsum sphere mimicking the osteonecrosis. Twenty sawbones were drilled by guidance of an intraoperative navigation system VectorVision (BrainLAB, Munich, Germany) and 10 sawbones by fluoroscopic control only. No gypsum sphere was missed. There was a statistically significant difference regarding the three-dimensional deviation (Euclidian norm) as well as maximum deviation in x-, y- or z-direction (maximum norm) to the desired mid-point of the lesion, with a mean of 0.51 and 0.4 mm in the navigated group and 1.1 and 0.88 mm in the control group, respectively. Furthermore, significant difference was found in the number of drilling corrections as well as the radiation time needed: no second drilling or correction of drilling direction was necessary in the navigated group compared to 1.4 in the control group. The radiation time needed was less than 1 s compared to 3.1 s, respectively. The fluoroscopy-based VectorVision navigation system shows a high feasibility of computer-guided drilling with a clear reduction of radiation exposure time and can therefore be integrated into clinical routine. The additional time needed is acceptable regarding the simultaneous reduction of radiation time.
Quantitative comparison of the microscopic anatomy of the human ACL femoral and tibial entheses.
Beaulieu, Mélanie L; Carey, Grace E; Schlecht, Stephen H; Wojtys, Edward M; Ashton-Miller, James A
2015-12-01
The femoral enthesis of the human anterior cruciate ligament (ACL) is known to be more susceptible to injury than the tibial enthesis. To determine whether anatomic differences might help explain this difference, we quantified the microscopic appearance of both entheses in 15 unembalmed knee specimens using light microscopy, toluidine blue stain and image analysis. The amount of calcified fibrocartilage and uncalcified fibrocartilage, and the ligament entheseal attachment angle were then compared between the femoral and tibial entheses via linear mixed-effects models. The results showed marked differences in anatomy between the two entheses. The femoral enthesis exhibited a 3.9-fold more acute ligament attachment angle than the tibial enthesis (p<0.001), a 43% greater calcified fibrocartilage tissue area (p<0.001), and a 226% greater uncalcified fibrocartilage depth (p<0.001), with the latter differences being particularly pronounced in the central region. We conclude that the ACL femoral enthesis has more fibrocartilage and a more acute ligament attachment angle than the tibial enthesis, which provides insight into why it is more vulnerable to failure. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Hip joint replacement using monofilament polypropylene surgical mesh: an animal model.
Białecki, Jacek; Majchrzycki, Marian; Szymczak, Antoni; Klimowicz-Bodys, Małgorzata Dorota; Wierzchoś, Edward; Kołomecki, Krzysztof
2014-01-01
Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur) leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS), triple pelvic osteotomy (TPO), total hip replacement (THR), and femoral head and neck resection (FHNE). The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform.
Aynardi, Michael C; Atwater, Lara C; Melvani, Roshan; Parks, Brent G; Paez, Adrian G; Miller, Stuart D
2017-10-01
Large Achilles tendon defects pose a treatment challenge. The standard treatment with a turndown flap requires a large extensile incision, puts the sural nerve at risk, and demands slow, careful rehabilitation. Dual allograft semitendinosus reconstruction is a new clinical alternative that has the theoretical advantages of a smaller incision, less dissection, and a stronger construct that may allow for faster rehabilitation. In a cadaver biomechanical model, we compared the dual allograft semitendinosus reconstruction with the myofascial turndown in terms of (1) mechanical strength and resistance to deformation and (2) failure mechanisms in reconstruction of large segmental Achilles defects. An 8-cm segmental Achilles defect was created in 18 cadaveric lower extremities, nine matched pairs without defect or previous surgery (mean age, 78.4 years; range, 60-97 years; three female and six male pairs). Femoral neck densitometry to determine bone mineral density found that all specimens except two were osteopenic or osteoporotic. Specimens in each pair were assigned to allograft or turndown reconstruction. The constructs were mounted on a load frame and differential variable reluctance transducers were applied to measure deformation. Specimens were preconditioned and then loaded axially. Tensile force and proximal and distal construct deformation were measured at clinical failure, defined as 10 mm of displacement, and at ultimate failure, defined as failure of the reconstruction. Failure mechanism was recorded. Tensile strength at time zero was higher in the allograft versus the turndown construct at clinical failure (156.9 ± 29.7 N versus 107.2 ± 20.0 N, respectively; mean difference, -49.7 N; 95% CI, -66.3 to -33.0 N; p < 0.001) and at ultimate failure (290.9 ± 83.2 N versus 140.7 ± 43.5 N, respectively; mean difference, -150.2 N; 95% CI, -202.9 to -97.6 N; p < 0.001). Distal construct deformation was lower in the turndown versus the allograft construct at clinical failure (1.6 ± 1.0 mm versus 4.7 ± 0.7 mm medially and 2.2 ± 1.0 mm versus 4.8 ± 1.1 mm laterally; p < 0.001). Semitendinosus allograft failure occurred via calcaneal bone bridge fracture in eight of nine specimens. All myofascial turndowns failed via suture pullout through the fascial tissue at its insertion. In this comparative biomechanical study, dual semitendinosus allograft reconstruction showed greater tensile strength and construct deformation compared with myofascial turndown in a cadaveric model of large Achilles tendon defects. Further study of dual semitendinosus allograft for treatment of severe Achilles tendon defects with cyclic loading and investigation of clinical results will better elucidate the clinical utility and indications for this technique.
Theodorou, E.G; Provatidis, C.G; Babis, G.C; Georgiou, C.S; Megas, P.D
2011-01-01
Total Hip Arthroplasty aims at fully recreating a functional hip joint. Over the past years modular implant systems have become common practice and are widely used, due to the surgical options they provide. In addition Big Femoral Heads have also been implemented in the process, providing more flexibility for the surgeon. The current study aims at investigating the effects that femoral heads of bigger diameter may impose on the mechanical behavior of the bone-implant assembly. Using data acquired by Computed Tomographies and a Coordinate Measurement Machine, a cadaveric femur and a Profemur-E modular stem were fully digitized, leading to a three dimensional finite element model in ANSYS Workbench. Strains and stresses were then calculated, focusing on areas of clinical interest, based on Gruen zones: the calcar and the corresponding below the greater trochanter area in the proximal femur, the stem tip region and a profile line along linea aspera. The performed finite elements analysis revealed that the use of large diameter heads produces significant changes in strain development within the bone volume, especially in the lateral side. The application of Frost’s law in bone remodeling, validated the hypothesis that for all diameters normal bone growth occurs. However, in the calcar area lower strain values were recorded, when comparing with the reference model featuring a 28mm femoral head. Along line aspera and for the stem tip area, higher values were recorded. Finally, stresses calculated on the modular neck revealed increased values, but without reaching the yield strength of the titanium alloy used. PMID:21792381
Theodorou, E G; Provatidis, C G; Babis, G C; Georgiou, C S; Megas, P D
2011-01-01
Total Hip Arthroplasty aims at fully recreating a functional hip joint. Over the past years modular implant systems have become common practice and are widely used, due to the surgical options they provide. In addition Big Femoral Heads have also been implemented in the process, providing more flexibility for the surgeon. The current study aims at investigating the effects that femoral heads of bigger diameter may impose on the mechanical behavior of the bone-implant assembly. Using data acquired by Computed Tomographies and a Coordinate Measurement Machine, a cadaveric femur and a Profemur-E modular stem were fully digitized, leading to a three dimensional finite element model in ANSYS Workbench. Strains and stresses were then calculated, focusing on areas of clinical interest, based on Gruen zones: the calcar and the corresponding below the greater trochanter area in the proximal femur, the stem tip region and a profile line along linea aspera. The performed finite elements analysis revealed that the use of large diameter heads produces significant changes in strain development within the bone volume, especially in the lateral side. The application of Frost's law in bone remodeling, validated the hypothesis that for all diameters normal bone growth occurs. However, in the calcar area lower strain values were recorded, when comparing with the reference model featuring a 28mm femoral head. Along line aspera and for the stem tip area, higher values were recorded. Finally, stresses calculated on the modular neck revealed increased values, but without reaching the yield strength of the titanium alloy used.
New approach to probability estimate of femoral neck fracture by fall (Slovak regression model).
Wendlova, J
2009-01-01
3,216 Slovak women with primary or secondary osteoporosis or osteopenia, aged 20-89 years, were examined with the bone densitometer DXA (dual energy X-ray absorptiometry, GE, Prodigy - Primo), x = 58.9, 95% C.I. (58.42; 59.38). The values of the following variables for each patient were measured: FSI (femur strength index), T-score total hip left, alpha angle - left, theta angle - left, HAL (hip axis length) left, BMI (body mass index) was calculated from the height and weight of the patients. Regression model determined the following order of independent variables according to the intensity of their influence upon the occurrence of values of dependent FSI variable: 1. BMI, 2. theta angle, 3. T-score total hip, 4. alpha angle, 5. HAL. The regression model equation, calculated from the variables monitored in the study, enables a doctor in praxis to determine the probability magnitude (absolute risk) for the occurrence of pathological value of FSI (FSI < 1) in the femoral neck area, i. e., allows for probability estimate of a femoral neck fracture by fall for Slovak women. 1. The Slovak regression model differs from regression models, published until now, in chosen independent variables and a dependent variable, belonging to biomechanical variables, characterising the bone quality. 2. The Slovak regression model excludes the inaccuracies of other models, which are not able to define precisely the current and past clinical condition of tested patients (e.g., to define the length and dose of exposure to risk factors). 3. The Slovak regression model opens the way to a new method of estimating the probability (absolute risk) or the odds for a femoral neck fracture by fall, based upon the bone quality determination. 4. It is assumed that the development will proceed by improving the methods enabling to measure the bone quality, determining the probability of fracture by fall (Tab. 6, Fig. 3, Ref. 22). Full Text (Free, PDF) www.bmj.sk.
Goebel, L; Zurakowski, D; Müller, A; Pape, D; Cucchiarini, M; Madry, H
2014-10-01
To compare the 2D and 3D MOCART system obtained with 9.4 T high-field magnetic resonance imaging (MRI) for the ex vivo analysis of osteochondral repair in a translational model and to correlate the data with semiquantitative histological analysis. Osteochondral samples representing all levels of repair (sheep medial femoral condyles; n = 38) were scanned in a 9.4 T high-field MRI. The 2D and adapted 3D MOCART systems were used for grading after point allocation to each category. Each score was correlated with corresponding reconstructions between both MOCART systems. Data were next correlated with corresponding categories of an elementary (Wakitani) and a complex (Sellers) histological scoring system as gold standards. Correlations between most 2D and 3D MOCART score categories were high, while mean total point values of 3D MOCART scores tended to be 15.8-16.1 points higher compared to the 2D MOCART scores based on a Bland-Altman analysis. "Defect fill" and "total points" of both MOCART scores correlated with corresponding categories of Wakitani and Sellers scores (all P ≤ 0.05). "Subchondral bone plate" also correlated between 3D MOCART and Sellers scores (P < 0.001). Most categories of the 2D and 3D MOCART systems correlate, while total scores were generally higher using the 3D MOCART system. Structural categories "total points" and "defect fill" can reliably be assessed by 9.4 T MRI evaluation using either system, "subchondral bone plate" using the 3D MOCART score. High-field MRI is valuable to objectively evaluate osteochondral repair in translational settings. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Ukwatta, Eranga; Yuan, Jing; Qiu, Wu; Rajchl, Martin; Chiu, Bernard; Fenster, Aaron
2015-12-01
Three-dimensional (3D) measurements of peripheral arterial disease (PAD) plaque burden extracted from fast black-blood magnetic resonance (MR) images have shown to be more predictive of clinical outcomes than PAD stenosis measurements. To this end, accurate segmentation of the femoral artery lumen and outer wall is required for generating volumetric measurements of PAD plaque burden. Here, we propose a semi-automated algorithm to jointly segment the femoral artery lumen and outer wall surfaces from 3D black-blood MR images, which are reoriented and reconstructed along the medial axis of the femoral artery to obtain improved spatial coherence between slices of the long, thin femoral artery and to reduce computation time. The developed segmentation algorithm enforces two priors in a global optimization manner: the spatial consistency between the adjacent 2D slices and the anatomical region order between the femoral artery lumen and outer wall surfaces. The formulated combinatorial optimization problem for segmentation is solved globally and exactly by means of convex relaxation using a coupled continuous max-flow (CCMF) model, which is a dual formulation to the convex relaxed optimization problem. In addition, the CCMF model directly derives an efficient duality-based algorithm based on the modern multiplier augmented optimization scheme, which has been implemented on a GPU for fast computation. The computed segmentations from the developed algorithm were compared to manual delineations from experts using 20 black-blood MR images. The developed algorithm yielded both high accuracy (Dice similarity coefficients ≥ 87% for both the lumen and outer wall surfaces) and high reproducibility (intra-class correlation coefficient of 0.95 for generating vessel wall area), while outperforming the state-of-the-art method in terms of computational time by a factor of ≈ 20. Copyright © 2015 Elsevier B.V. All rights reserved.
Maruki, Hideyuki; Sato, Masato; Takezawa, Toshiaki; Tani, Yoshiki; Yokoyama, Munetaka; Takahashi, Takumi; Toyoda, Eriko; Okada, Eri; Aoki, Shigehisa; Mochida, Joji; Kato, Yoshiharu
2017-11-01
We studied the ability of collagen vitrigel material to repair cartilage in vivo when used alone or with transforming growth factor-β (TGF-β). We measured the time course and quantity of TGF-β1 released from the collagen vitrigel in vitro to quantify the controlled release of TGF-β1. Over 14 days, 0.91 ng of TGF-β was released from the collagen vitrigel. Osteochondral defects were made in the femoral trochlear groove in 36 Japanese white rabbits, which were divided into three groups: untreated group (group A), collagen vitrigel-implanted group (group B), and TGF-β1-incorporated collagen vitrigel-implanted group (group C). The weight distribution ratio between the affected and unaffected limbs served as an indicator of pain. Animals were sacrificed at 4 and 12 weeks after surgery, and their tissues were assessed histologically. The weight distribution ratio increased in all groups and did not differ significantly between groups at 12 weeks. Group A needed 6 weeks to attain maximum improvement, and groups B and C showed near-maximum improvement at 4 and 2 weeks, respectively. The International Cartilage Repair Society II score improved significantly in group C relative to the other groups. These findings suggest that sustained, slow release of TGF-β caused early pain mitigation and cartilage repair. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2592-2602, 2017. © 2016 Wiley Periodicals, Inc.
Dashtdar, Havva; Murali, Malliga Raman; Abbas, Azlina Amir; Suhaeb, Abdulrazzaq Mahmod; Selvaratnam, Lakshmi; Tay, Liang Xin; Kamarul, Tunku
2015-05-01
To investigate whether mesenchymal stem cells (MSCs) seeded in novel polyvinyl alcohol (PVA)-chitosan composite hydrogel can provide comparable or even further improve cartilage repair outcomes as compared to previously established alginate-transplanted models. Medial femoral condyle defect was created in both knees of twenty-four mature New Zealand white rabbits, and the animals were divided into four groups containing six animals each. After 3 weeks, the right knees were transplanted with PVA-chitosan-MSC, PVA-chitosan scaffold alone, alginate-MSC construct or alginate alone. The left knee was kept as untreated control. Animals were killed at the end of 6 months after transplantation, and the cartilage repair was assessed through Brittberg morphological score, histological grading by O'Driscoll score and quantitative glycosaminoglycan analysis. Morphological and histological analyses showed significant (p < 0.05) tissue repair when treated with PVA-chitosan-MSC or alginate MSC as compared to the scaffold only and untreated control. In addition, safranin O staining and the glycosaminoglycan (GAG) content were significantly higher (p < 0.05) in MSC treatment groups than in scaffold-only or untreated control group. No significant difference was observed between the PVA-chitosan-MSC- and alginate-MSC-treated groups. PVA-chitosan hydrogel seeded with mesenchymal stem cells provides comparable treatment outcomes to that of previously established alginate-MSC construct implantation. This study supports the potential use of PVA-chitosan hydrogel seeded with MSCs for clinical use in cartilage repair such as traumatic injuries.
Mortality Following Periprosthetic Proximal Femoral Fractures Versus Native Hip Fractures.
Boylan, Matthew R; Riesgo, Aldo M; Paulino, Carl B; Slover, James D; Zuckerman, Joseph D; Egol, Kenneth A
2018-04-04
The number of periprosthetic proximal femoral fractures is expected to increase with the increasing prevalence of hip arthroplasties. While native hip fractures have a well-known association with mortality, there are currently limited data on this outcome among the subset of patients with periprosthetic proximal femoral fractures. Using the New York Statewide Planning and Research Cooperative System, we identified patients from 60 to 99 years old who were admitted to a hospital in the state with a periprosthetic proximal femoral fracture (n = 1,655) or a native hip (femoral neck or intertrochanteric) fracture (n = 97,231) between 2006 and 2014. Within the periprosthetic fracture cohort, the indication for the existing implant was not available in the data set. We used mixed-effects regression models to compare mortality at 1 and 6 months and 1 year for periprosthetic compared with native hip fractures. The risk of mortality for patients who sustained a periprosthetic proximal femoral fracture was no different from that for patients who sustained a native hip fracture at 1 month after injury (3.2% versus 4.6%; odds ratio [OR], 0.90; 95% confidence interval [CI], 0.68 to 1.19; p = 0.446), but was lower at 6 months (3.8% versus 6.5%; OR, 0.74; 95% CI, 0.57 to 0.95; p = 0.020) and 1 year (9.7% versus 15.9%; OR, 0.71; 95% CI, 0.60 to 0.85; p < 0.001). Among periprosthetic proximal femoral fractures, factors associated with a significantly increased risk of mortality at 1 year included advanced age, male sex, and higher Deyo comorbidity scores. In the acute phase, any type of hip fracture appears to confer a similar risk of death. Over the long term, however, periprosthetic proximal femoral fractures are associated with lower mortality rates than native hip fractures, even after accounting for age and comorbidities. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Relationship of femoral artery ultrasound measures of atherosclerosis with chronic kidney disease.
Hsu, Simon; Rifkin, Dena E; Criqui, Michael H; Suder, Natalie C; Garimella, Pranav; Ginsberg, Charles; Marasco, Antoinette M; McQuaide, Belinda J; Barinas-Mitchell, Emma J; Allison, Matthew A; Wassel, Christina L; Ix, Joachim H
2017-12-22
Chronic kidney disease (CKD) is strongly associated with peripheral artery disease (PAD). Detection of subclinical PAD may allow early interventions for or prevention of PAD in persons with CKD. Whether the presence of atherosclerotic plaque and femoral intima-media thickness (IMT) are associated with kidney function is unknown. We performed a cross-sectional observational study of 1029 community-living adults. We measured superficial and common femoral artery IMT and atherosclerotic plaque presence by ultrasound. Estimated glomerular filtration rate (eGFR; continuous) and eGFR <60 mL/min/1.73 m 2 (binary) were evaluated as outcomes. Mean age was 70 ± 10 years, mean eGFR was 78 ± 17 mL/min/1.73 m 2 , and 156 (15%) individuals had eGFR <60 mL/min/1.73 m 2 ; 260 (25%) had femoral artery plaque. In models adjusted for demographics and cardiovascular risk factors, individuals with femoral artery plaque had mean eGFR approximately 3.0 (95% confidence interval, -5.3 to -0.8) mL/min/1.73 m 2 lower than those without plaque (P < .01). The presence of plaque was also associated with a 1.7-fold higher odds of eGFR <60 mL/min/1.73 m 2 (95% confidence interval, 1.1-2.8; P < .02). Associations were similar in persons with normal ankle-brachial index. The directions of associations were similar for femoral IMT measures with eGFR and CKD but were rendered no longer statistically significant with adjustment for demographic variables and cardiovascular disease risk factors. Femoral artery plaque is significantly associated with CKD prevalence in community-living individuals, even among those with normal ankle-brachial index. Femoral artery ultrasound may allow evaluation of relationships and risk factors linking PAD and kidney disease earlier in its course. Copyright © 2017 Society for Vascular Surgery. All rights reserved.
Whitney, Darryl C; Sturnick, Daniel R; Vacek, Pamela M; DeSarno, Mike J; Gardner-Morse, Mack; Tourville, Timothy W; Smith, Helen C; Slauterbeck, James R; Johnson, Robert J; Shultz, Sandra J; Hashemi, Javad; Beynnon, Bruce D
2014-08-01
The morphometric characteristics of the anterior cruciate ligament (ACL) and the femoral intercondylar notch within which it resides have been implicated as risk factors for injuries to this important stabilizer of the knee. Prior research has produced equivocal results with differing methodologies, and consequently, it is unclear how these characteristics affect the injury risk in male and female patients. The morphometric characteristics of the ACL and femoral intercondylar notch are individually and independently associated with the risk of suffering a noncontact ACL injury, and these relationships are different in male and female patients. Case-control study; Level of evidence, 3. Magnetic resonance imaging scans of the bilateral knees were obtained on 88 case-control pairs (27 male, 61 female) matched for age, sex, and participation on the same sports team. Patients had suffered a grade III, first-time, noncontact ACL tear. The femoral notch width at 4 locations, the thickness of the bony ridge at the anteromedial outlet of the femoral notch, the femoral notch volume, ACL volume, and ACL cross-sectional area were measured. Multivariate analysis of combined data from male and female patients revealed that decreased ACL volume (odds ratio [OR], 0.829), decreased femoral notch width (OR, 0.700), and increased bony ridge thickness at the anteromedial outlet of the femoral notch (OR, 1.614) were significant independent predictors of an ACL injury. Separate analyses of male and female patients indicated that the femoral notch ridge may be more strongly associated with a risk in female patients, while ACL volume is more strongly associated with a risk in male patients. However, statistical analysis performed with an adjustment for body weight strengthened the association between ACL volume and the risk of injuries in female patients. Morphometric features of both the ACL and femoral notch combine to influence the risk of suffering a noncontact ACL injury. When included together in a multivariate model that adjusts for body weight, the effects of the morphometric measurements are similar in male and female patients. If body weight is not taken into consideration, ACL volume is not associated with a risk in female patients. © 2014 The Author(s).
Venting during prophylactic nailing for femoral metastases: current orthopedic practice.
Dalgorf, Dustin; Borkhoff, Cornelia M; Stephen, David J G; Finkelstein, Joel; Kreder, Hans J
2003-12-01
Reamed intramedullary nailing, recommended for impending fracture of a femur weakened by bone metastases, causes a rise in intramedullary pressure and increases the risk of a fat embolism syndrome. The pressure can be equalized by the technique of venting--drilling a hole into the distal cortex of the femur. Our objective was to study the current practice of orthopedic surgeons in Ontario with respect to venting during prophylactic intramedullary nailing for an impending femoral fracture due to bone metastases. We mailed a questionnaire to all orthopedic surgeons from the Province of Ontario listed in the 1999 Canadian Medical Directory or on the Canadian Orthopaedic Association membership list, asking if they vent when prophylactically nailing an impending pathologic femoral fracture. The responses were modelled as a function of surgeon volume and year of graduation. Of the 415 surveys mailed, 223 (54%) surgeons responded. Of these, 81% reported having prophylactically treated a femoral metastatic lesion during the previous year; 67% treated 1 to 3 metastatic lesions and 14% treated more than 3; 19% did not treat a metastatic femoral lesion prophylactically. Over two-thirds of surgeons had never considered venting, whereas one-third always or sometimes vented the femoral canal. More recent graduates were 3 times more likely to vent than earlier (before 1980) graduates (odds ratio [OR] = 3.2, 95% confidence interval [CI] 1.6-6.5) as were those who treat a greater number of impending fractures (OR = 1.4, 95% CI 1.1-1.7). Although there is a theoretical rationale for routine venting, there is disagreement among Ontario orthopedic surgeons regarding the use of this technique during prophylactic nailing for femoral metastatic lesions. Prospective evidence will be required to warrant a change in the standard of care.
Brar, Abheetinder S; Howell, Stephen M; Hull, Maury L; Mahfouz, Mohamed R
2016-08-01
Kinematically aligned total knee arthroplasty uses a femoral component designed for mechanical alignment (MA) and sets the component in more internal, valgus, and flexion rotation than MA. It is unknown how much kinematic alignment (KA) and flexion of the femoral component reduce the proximal and lateral reach of the trochlea; two reductions that could increase the risk of abnormal patella tracking. We simulated MA and KA of the femoral component in 0° of flexion on 20 3-dimensional bone models of normal femurs. The mechanically and kinematically aligned components were then aligned in 5°, 10°, and 15° of flexion and downsized until the flange contacted the anterior femur. The reductions in the proximal and lateral reach from the proximal point of the trochlea of the MA component set in 0° of flexion were computed. KA at 0° of flexion did not reduce the proximal reach and reduced the lateral reach an average of 3 mm. Flexion of the MA and KA femoral component 5°, 10°, and 15° reduced the proximal reach an average of 4 mm, 8 mm, and 12 mm, respectively (0.8 mm/degree of flexion), and reduced the lateral reach an average of 1 mm and 4 mm regardless of the degree of flexion, respectively. Arthroplasty surgeons and biomechanical engineers striving to optimize patella tracking might consider developing surgical techniques to minimize flexion of the femoral component when performing KA and MA total knee arthroplasty to promote early patella engagement and consider designing a femoral component with a trochlea shaped specifically for KA. Copyright © 2016 Elsevier Inc. All rights reserved.
Chou, Ying-Chao; Cheng, Yi-Shiun; Hsu, Yung-Heng; Yu, Yi-Hsun; Liu, Shih-Jung
2016-04-01
The aim of this study was to evaluate the efficacy of a biodegradable, lidocaine-embedded, nanofibrous membrane for the sustainable analgesic release onto fragments of a segmental femoral fracture site. Membranes of three different lidocaine concentrations (10%, 30%, and 50%) were produced via an electrospinning technique. In vitro lidocaine release was assessed by high-performance liquid chromatography. A femoral segmental fracture, with intramedullary Kirschner-wire fixation and polycaprolactone stent enveloping the fracture site, was set-up in a rabbit model for in vivo assessment of post-operative recovery of activity. Eighteen rabbits were randomly assigned to three groups (six rabbits per group): group A comprised of rabbits with femoral fractures and underwent fixation; group B comprised of a comparable fracture model to that of group A with the implantation of lidocaine-loaded nanofibers; and group C, the control group, received only anesthesia. The following variables were measured: change in body weight, food and water intake before and after surgery, and total activity count post-surgery. All membranes eluted effective levels of lidocaine for more than 3 weeks post-surgery. Rabbits in group B showed faster recovery of activity post-operatively, compared with those in group A, which confirmed the pain relief efficacy of the lidocaine-embedded nanofibers. Nanofibers with sustainable lidocaine release have adequate efficacy and durability for pain relief in rabbits with segmental long bone fractures. Copyright © 2016 Elsevier B.V. All rights reserved.
Outerbridge Grade IV Cartilage Lesions in the Hip Identified at Arthroscopy.
Bhatia, Sanjeev; Nowak, Douglas D; Briggs, Karen K; Patterson, Diana C; Philippon, Marc J
2016-05-01
To determine factors associated with grade IV cartilage defects in the hip in patients undergoing hip arthroscopy with joint pain. Data from consecutive patients who underwent hip arthroscopy performed by a single surgeon over a period of 4 years were included in this study. The study group included 1,097 patients (491 women and 606 men; mean age, 37 years) who underwent hip arthroscopy for pain, had no prior hip surgery, and were aged 18 years or older. Preoperative radiographs, patient demographic characteristics, and operative details were used to identify risk factors for cartilage defects. Grade IV chondral defects were present in 308 of 1,097 hips (28%). Isolated chondral lesions were more frequently observed on the acetabulum (76%) than on the femoral head (24%). Defects of the acetabulum were more commonly anterosuperior (94.7%) and less commonly posterolateral (5.3%). Patients with less than 2 mm of joint space on preoperative radiographs were 8 times more likely to have a grade IV lesion than those with more than 2 mm. Men were more likely than women to have grade IV lesions (35% v 19%, P = .0001); patients with grade IV lesions were older than those without (42 years v 34 years, P = .0001). Hips with grade IV lesions had significantly higher alpha angles than those without (74° v 70°, P = .0001). Patients with grade IV defects reported a longer duration of symptoms than those without (37 months v 27 months, P = .007). Independent risk factors for the presence of grade IV chondral defects were less than 2 mm of joint space, male gender, increasing age, larger alpha angle, and longer duration of symptoms. Grade IV chondral defects in patients undergoing hip arthroscopy were associated with decreased joint space, increased time from symptom onset to arthroscopy, male gender, and larger alpha angles associated with femoroacetabular impingement. Level IV, prognostic case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Morphometric analysis of acetabular dysplasia in cerebral palsy: three-dimensional CT study.
Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi
2009-12-01
Three-dimensional computed tomography (3D-CT) eliminates the positioning errors and allows the clinician to more accurately assess the radiographic parameters present. To elucidate the 3D geometry of the acetabulum and the extent of hip subluxation/dislocation in patients with cerebral palsy (CP), quantitative morphometric analysis was performed using 3D-CT data. We evaluated 150 hips in 75 patients with bilateral spastic CP. The mean age of the patients was 5.4 years (range: 2.7 to 6.9 y). The fitting plane of the ilium was projected onto the coronal plane and then onto the sagittal plane, and then the angle formed with a horizontal line was defined as CTalpha (the lateral opening angle) and CTbeta (the sagittal inclination angle), respectively. The center of the acetabulum and the femoral head were defined, and the distance between these centers was divided by the femoral head diameter, defined as CT migration percentage (CTMP, %). In 123 (82%) of the 150 hips, the femoral head center was located posteriorly, superiorly, and laterally relative to the acetabular center. Large CTalpha cases tended to show large CTMP. CTalpha and CTMP were significantly larger in the cases with Gross Motor Functional Classification System (GMFCS) level IV/V and spastic quadriplegia, than in the cases with GMFCS level II/III and spastic diplegia. CTbeta showed significant correlation with the acetabular defect on the lateral 3D reconstructed images. Three-dimensional acetabular geometry and migration percentage in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. The extent of acetabular dysplasia and subluxation is more severe in patients with GMFCS level IV/V and spastic quadriplesia. Level 4.
Kim, Ha Yong; Cha, Yong Han; Choy, Won Sik; Jeung, Sang Wook; Min, Yeon Seung
2018-05-01
This research focuses on femoral head wedge resection for the treatment of avascular necrosis (AVN) of the femoral head. A 9-year-old girl presented to the emergency room complaining of right hip pain that occurred after a pedestrian car accident. After 8 months of internal fixation using cannulated screws for Delbet-type 2 fracture of the femoral neck, AVN of the femoral head developed in the patient. Even though valgus-derotation-extension intertrochanteric osteotomy was performed for the treatment of AVN, it progressed further and femoral head wedge resection was performed to recover the femoral head sphericity. After 3 years of follow-up, radiograph results showed appropriate and satisfactory congruency and containment. This research shows that the treatment of AVN of the femoral head using femoral head wedge resection is an effective method that can yield excellent results.
Santanelli Di Pompeo, Fabio; Longo, Benedetto; Pagnoni, Marco; Laporta, Rosaria
2015-05-01
Recidivating pressure sores are a frequent complication in meningomyelocele patients because of their limitation in motility and their scarce ability to monitor the pressure applied on insensate areas while seated. We report the utilization of the sensate pedicled anterolateral thigh perforator flap for reconstruction of ischiatic sores in meningomyelocele patients. Between May 2011 and September 2013, five patients underwent transfer of a sensate pedicled anterolateral thigh flap, by an intermuscular passageway through the upper thigh, to reach the ischial defect. Flap was properly harvested from the thigh after assessment of the lateral cutaneous femoral nerve sensitive area with the Pressure-Specified Sensory Device. In all cases the flap reached the ischial defect harmlessly, healing was uneventful with no immediate nor late complications. Each patient showed persistence of sensitivity at the reconstructed area and no recurrent ischiatic sore was observed at mean follow-up of 26.4 months. The sensate pedicled anterolateral thigh flap is a valuable solution for coverage of recurrent ischial sores in meningomyelocele patients, in which pressure consciousness is fundamental. The intermuscular passageway allows to reduce the distance between flap's vascular pedicle origin and the ischial defect, hence to use the more reliable skin from the middle third of the anterolateral thigh. © 2014 Wiley Periodicals, Inc.
Gil-Albarova, Jorge; Garrido-Lahiguera, Ruth; Salinas, Antonio J; Román, Jesús; Bueno-Lozano, Antonio L; Gil-Albarova, Raúl; Vallet-Regí, María
2004-08-01
The in vivo evaluation, in New Zealand rabbits, of a SiO(2)-P(2)O(5)-CaO sol-gel glass and a SiO(2)-P(2)O(5)-CaO-MgO glass-ceramic, both bioactive in Kokubo's simulated body fluid (SBF), is presented. Bone defects, performed in the lateral aspect of distal right femoral epiphysis, 5mm in diameter and 4mm in depth, were filled with (i) sol-gel glass disks, (ii) glass-ceramic disks, or (iii) no material (control group). Each group included 8 mature and 8 immature rabbits. A 4-month radiographic study showed good implant stability without axial deviation of extremities in immature animals and periosteal growth and remodelling around and over the bone defect. After sacrifice, the macroscopic study showed healing of bone defects, with bone coating over the implants. The morphometric study showed a more generous bone formation in animals receiving sol-gel glass or glass-ceramic disks than in control group. Histomorphometric study showed an intimate union of the new-formed bone to the implants. This study allows considering both materials as eligible for bone substitution or repair. Their indications could include cavities filling and the coating of implant surfaces. The minimum degradation of glass-ceramic disks suggests its application in locations of load or transmission forces. As specific indication in growth plate surgery, both materials could be used as material of interposition after bony bridges resection.
Wang, Xinyang; Wang, Yuanyuan; Bennell, Kim L; Wrigley, Tim V; Cicuttini, Flavia M; Fortin, Karine; Saxby, David J; Van Ginckel, Ans; Dempsey, Alasdair R; Grigg, Nicole; Vertullo, Christopher; Feller, Julian A; Whitehead, Tim; Lloyd, David G; Bryant, Adam L
2017-02-01
To examine differences in cartilage morphology between young adults 2-3 years post-anterior cruciate ligament reconstruction (ACLR), with or without meniscal pathology, and control participants. Knee MRI was performed on 130 participants aged 18-40 years (62 with isolated ACLR, 38 with combined ACLR and meniscal pathology, and 30 healthy controls). Cartilage defects, cartilage volume and bone marrow lesions (BMLs) were assessed from MRI using validated methods. Cartilage defects were more prevalent in the isolated ACLR (69 %) and combined group (84 %) than in controls (10 %, P < 0.001). Furthermore, the combined group showed higher prevalence of cartilage defects on medial femoral condyle (OR 4.7, 95 % CI 1.3-16.6) and patella (OR 7.8, 95 % CI 1.5-40.7) than the isolated ACLR group. Cartilage volume was lower in both ACLR groups compared with controls (medial tibia, lateral tibia and patella, P < 0.05), whilst prevalence of BMLs was higher on lateral tibia (P < 0.001), with no significant differences between the two ACLR groups for either measure. Cartilage morphology was worse in ACLR patients compared with healthy controls. ACLR patients with associated meniscal pathology have a higher prevalence of cartilage defects than ACLR patients without meniscal pathology. The findings suggest that concomitant meniscal pathology may lead to a greater risk of future OA than isolated ACLR. III.
Janko, Maren; Dietz, Konstantin; Rachor, Julia; Sahm, Julian; Schroder, Katrin; Schaible, Alexander; Nau, Christoph; Seebach, Caroline; Marzi, Ingo; Henrich, Dirk
2018-04-23
Transplanted bone marrow mononuclear cells (BMC) support the healing of large bone defects. Neutralization of microRNA (MiR) that negatively affects key processes of the reparative response in BMC might help to further improve the beneficial effect of transplanted BMC in bone healing. Hence, the aim of this study was to evaluate if the neutralization of MiR-92A (vascularization) and MiR-335-5p (osteogenic differentiation) in BMC using specific antiMiRs leads to a further improvement of the BMC-supported therapy of large bone defects. BMC transiently transfected with antiMiR- 92A, antiMiR-335, antiMiR-92A, and antiMiR-355 or control antiMiR were seeded on β-TCP (beta-tricalcium phosphate) and placed in a femoral large bone defect (5 mm) in Sprague-Dawley rats. Ultimate load as well as osseous integration of the β-TCP-scaffolds were significantly improved in the antiMiR-335 group compared to the control group after 8 weeks, whereas neutralization of antiMiR-92A lead to an improvement of early vascularization after 1 week, but not to enhanced bone healing after 8 weeks. We demonstrated that the targeted inhibition of MiRs in transplanted BMC is a new approach that enhances BMC-supported bone healing.
Terjesen, Terje; Wiig, Ola; Svenningsen, Svein
2012-09-01
In the Norwegian prospective study on Legg-Calvé-Perthes disease (LCPD), we found varus femoral osteotomy gave better femoral head sphericity at a mean of 5 years postoperative than physiotherapy in children older than 6.0 years at diagnosis with femoral head necrosis of more than 50%. That study did not include separate analyses for hips with 100% necrosis and those with a percentage of necrosis between 50% and 100%. We asked whether (1) femoral osteotomy improves femoral head sphericity at followup in all patients with more than 50% femoral head necrosis or in selected groups only and (2) there is a critical age between 6.0 and 10.0 years over which femoral osteotomy does not improve the prognosis. We treated 70 patients with unilateral LCPD, age at diagnosis of more than 6.0 years, and femoral head necrosis of more than 50% with varus femoral osteotomy between 1996 and 2000. We classified necrosis using the Catterall classification. We established a control group of 51 similar children who received physiotherapy. At the 5-year followup visit, the hips were graded according to femoral head shape: spherical, ovoid, or flat. At 5-year followup, there was no difference between the treatment groups in radiographic outcome in Catterall Group 3 hips. In Catterall Group 4 hips, femoral head sphericity was better in the osteotomy group, with flat femoral heads in 14% compared to 75% after physiotherapy. The same trend toward better head sphericity occurred when the lateral pillar classification was used. In children aged 6.0 to 10.0 years, in whom the whole femoral head is affected, femoral head sphericity 5 years after femoral osteotomy was better than that after physiotherapy.
Gasior, Pawel; Cheng, Yanping; Valencia, Andres F; McGregor, Jenn; Conditt, Gerard B; Kaluza, Grzegorz L; Granada, Juan F
2017-05-01
A polymer-free peripheral paclitaxel-eluting stent (PES, Zilver PTX, Cook, IN) has shown to improve vessel patency after superficial femoral angioplasty. A new-generation fluoropolymer-based PES (FP-PES; Eluvia, Boston Scientific, MA) displaying more controlled and sustained paclitaxel delivery promise to improve the clinical outcomes of first-generation PES. We sought to compare the biological effect of paclitaxel delivered by 2 different stent-coating technologies (fluoropolymer-based versus polymer-free) on neointimal proliferation and healing response in the familial hypercholesterolemic swine model of femoral restenosis. The biological efficacy of clinically available FP-PES (n=12) and PES (n=12) was compared against a bare metal stent control (n=12; Innova, Boston Scientific, MA) after implantation in the femoral arteries of 18 familial hypercholesterolemic swine. Longitudinal quantitative vascular angiography and optical coherence tomography were performed at baseline and at 30 and 90 days. Histological evaluation was performed at 90 days. Ninety-day quantitative vascular angiography results showed a lower percent diameter stenosis for FP-PES (38.78% [31.27-47.66]) compared with PES (54.16% [42.60-61.97]) and bare metal stent (74.52% [47.23-100.00]; P <0.001). Ninety-day optical coherence tomography results demonstrated significantly lower neointimal area in FP-PES (8.01 mm 2 [7.65-9.21]) compared with PES (10.95 mm 2 [9.64-12.46]) and bare metal stent (13.83 mm 2 [11.53-17.03]; P <0.001). Histological evaluation showed larger lumen areas and evidence of higher biological activity (smooth muscle cell loss and fibrin deposition) in the FP-PES compared with PES and bare metal stent. In the familial hypercholesterolemic swine model of femoral restenosis, the implantation of an FP-PES resulted in lower levels of neointimal proliferation and sustained biological effect ≤90 days compared with a polymer-free stent-based approach. © 2017 American Heart Association, Inc.
Brandt, J-M; Guenther, L; O'Brien, S; Vecherya, A; Turgeon, T R; Bohm, E R
2013-12-01
The surface characteristics of the femoral component affect polyethylene wear in modular total knee replacements. In the present retrieval study, the surface characteristics of cobalt-chromium (CoCr) alloy and oxidized zirconium (OxZr) femoral components were assessed and compared. Twenty-six retrieved CoCr alloy femoral components were matched with twenty-six retrieved OxZr femoral components for implantation period, body-mass index, patient gender, implant type, and polyethylene insert thickness. The surface damage on the retrieved femoral components was evaluated using a semi-quantitative assessment method, scanning electron microscopy, and contact profilometry. The retrieved CoCr alloy femoral components showed less posterior surface gouging than OxZr femoral components; however, at a higher magnification, the grooving damage features on the retrieved CoCr alloy femoral components confirmed an abrasive wear mechanism. The surface roughness values Rp, Rpm, and Rpk for the retrieved CoCr alloy femoral components were found to be significantly higher than those of the retrieved OxZr femoral components (p≤0.031). The surface roughness values were higher on the medial condyles than on the lateral condyles of the retrieved CoCr alloy femoral components; such a difference was not observed on the retrieved OxZr femoral components. The surface roughness of CoCr alloy femoral components increased while the surface roughness of the OxZr femoral components remained unchanged after in vivo service. Therefore, the OxZr femoral components' resistance to abrasive wear may enable lower polyethylene wear and ensure long-term durability in vivo. Level IV. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.
Limited rotation of the mobile-bearing in a rotating platform total knee prosthesis.
Garling, E H; Kaptein, B L; Nelissen, R G H H; Valstar, E R
2007-01-01
The hypothesis of this study was that the polyethylene bearing in a rotating platform total knee prosthesis shows axial rotation during a step-up motion, thereby facilitating the theoretical advantages of mobile-bearing knee prostheses. We examined 10 patients with rheumatoid arthritis who had a rotating platform total knee arthroplasty (NexGen LPS mobile, Zimmer Inc. Warsaw, USA). Fluoroscopic data was collected during a step-up motion six months postoperatively. A 3D-2D model fitting technique was used to reconstruct the in vivo 3D kinematics. The femoral component showed more axial rotation than the polyethylene mobile-bearing insert compared to the tibia during extension. In eight knees, the femoral component rotated internally with respect to the tibia during extension. In the other two knees the femoral component rotated externally with respect to the tibia. In all 10 patients, the femur showed more axial rotation than the mobile-bearing insert indicating the femoral component was sliding on the polyethylene of the rotating platform during the step-up motion. Possible explanations are a too limited conformity between femoral component and insert, the anterior located pivot location of the investigated rotating platform design, polyethylene on metal impingement and fibrous tissue formation between the mobile-bearing insert and the tibial plateau.
Hip Joint Replacement Using Monofilament Polypropylene Surgical Mesh: An Animal Model
Białecki, Jacek; Klimowicz-Bodys, Małgorzata Dorota; Wierzchoś, Edward; Kołomecki, Krzysztof
2014-01-01
Hip joint dysplasia is a deformation of the articular elements (pelvic acetabulum, head of the femur, and/or ligament of the head of the femur) leading to laxity of the hip components and dislocation of the femoral head from the pelvic acetabulum. Diagnosis is based on symptoms observed during clinical and radiological examinations. There are two treatment options: conservative and surgical. The classic surgical procedures are juvenile pubic symphysiodesis (JPS), triple pelvic osteotomy (TPO), total hip replacement (THR), and femoral head and neck resection (FHNE). The aim of this experiment was to present an original technique of filling the acetabulum with a polypropylene implant, resting the femoral neck directly on the mesh. The experiment was performed on eight sheep. The clinical value of the new surgical technique was evaluated using clinical, radiological, and histological methods. This technique helps decrease the loss of limb length by supporting the femoral neck on the mesh equivalent to the femoral head. It also reduces joint pain and leads to the formation of stable and mobile pseudarthrosis. The mesh manifested osteoprotective properties and enabled the formation of a stiff-elastic connection within the hip joint. The method is very cost-effective and the technique itself is simple to perform. PMID:24987672
Citrus juice modulates bone strength in male senescent rat model of osteoporosis.
Deyhim, Farzad; Garica, Kristy; Lopez, Erica; Gonzalez, Julia; Ino, Sumiyo; Garcia, Michelle; Patil, Bhimanagouda S
2006-05-01
An experiment evaluated the effect of citrus juice on enhancing serum antioxidant status and on osteoporosis prevention in orchidectomized rats. Thirty-six 1-y-old male rats were randomized to two groups: a sham-control group (n = 9) and an orchidectomized group (n = 27). The orchidectomized group was divided into three groups of nine and assigned to one of the following treatments: orchidectomy, orchidectomy plus orange juice, and orchidectomy plus grapefruit juice. Sixty days after initiation of the study, all rats were killed, blood was collected, and serum was harvested for total antioxidant status and indices of bone formation and resorption. Femoral density and biomechanical properties were monitored. Orchidectomy decreased (P < 0.05) total antioxidant capacity, femoral density, and biomechanical properties and increased (P < 0.05) alkaline phosphatase, acid phosphatase, and urinary excretion of hydroxyproline compared with the sham-control group. In contrast to orchidectomy, orchidectomy plus orange juice and orchidectomy plus grapefruit juice reversed (P < 0.05) orchidectomy-induced antioxidant suppression, decreased (P < 0.05) alkaline phosphatase and acid phosphatase activities, moderately restored (P = 0.07) femoral density, increased (P < 0.05) femoral strength, significantly delayed time-induced femoral fracture, and decreased (P < 0.05) urinary excretion of hydroxyproline. The present study supports the supposition in that drinking citrus juice positively affects serum antioxidant status and bone strength.
Du, Zhe; Chen, Shichang; Yan, Mengning; Yue, Bing; Zeng, Yiming; Wang, You
2017-01-06
Our study aimed to investigate whether geometrical features (size, shape, or alignment parameters) of the femoral condyle affect the morphology of the trochlear groove. Computed tomography models of 195 femurs (97 and 98 knees from male and female subjects, respectively) were reconstructed into three-dimensional models and categorised into four types of trochlear groove morphology based on the position of the turning point in relation to the mechanical axis (types 45°, 60°, 75°, and 90°). Only subjects with healthy knees were included, whereas individuals with previous knee trauma or knee pain, soft tissue injury, osteoarthritis, or other chronic diseases of the musculoskeletal system were excluded. The size parameters were: radius of the best-fit cylinder, anteroposterior dimension of the lateral condyles (AP), and distal mediolateral dimension (ML). The shape parameters were: aspect ratio (AP/ML), arc angle, and proximal- and distal- end angles. The alignment parameters were: knee valgus physiologic angle (KVPA), mechanical medial distal femoral angle (mMDFA), and hip-knee-ankle angle (HKA). All variables were measured in the femoral condyle models, and the means for each groove type were compared using one-way analysis of variance. No significant difference among groove types was observed regarding size parameters. There were significant differences when comparing type 45° with types 60°, 75°, and 90° regarding aspect ratio and distal-end angle (p < 0.05), but not regarding proximal-end angle. There were significant differences when comparing type 90° with types 45°, 60°, and 75° regarding KVPA, mMDFA, and HKA (p < 0.05). Among size, shape, and alignment parameters, the latter two exhibited partial influence on the morphology of the trochlear groove. Shape parameters affected the trochlear groove for trochlear type 45°, for which the femoral condyle was relatively flat, whereas alignment parameters affected the trochlear groove for trochlear type 90°, showing that knees in type 90° tend to be valgus. The morphometric analysis based on trochlear groove classification may be helpful for the future design of individualized prostheses.
Active shape modeling of the hip in the prediction of incident hip fracture.
Baker-LePain, Julie C; Luker, Kali R; Lynch, John A; Parimi, Neeta; Nevitt, Michael C; Lane, Nancy E
2011-03-01
The objective of this study was to evaluate right proximal femur shape as a risk factor for incident hip fracture using active shape modeling (ASM). A nested case-control study of white women 65 years of age and older enrolled in the Study of Osteoporotic Fractures (SOF) was performed. Subjects (n = 168) were randomly selected from study participants who experienced hip fracture during the follow-up period (mean 8.3 years). Controls (n = 231) had no fracture during follow-up. Subjects with baseline radiographic hip osteoarthritis were excluded. ASM of digitized right hip radiographs generated 10 independent modes of variation in proximal femur shape that together accounted for 95% of the variance in proximal femur shape. The association of ASM modes with incident hip fracture was analyzed by logistic regression. Together, the 10 ASM modes demonstrated good discrimination of incident hip fracture. In models controlling for age and body mass index (BMI), the area under receiver operating characteristic (AUROC) curve for hip shape was 0.813, 95% confidence interval (CI) 0.771-0.854 compared with models containing femoral neck bone mineral density (AUROC = 0.675, 95% CI 0.620-0.730), intertrochanteric bone mineral density (AUROC = 0.645, 95% CI 0.589-0.701), femoral neck length (AUROC = 0.631, 95% CI 0.573-0.690), or femoral neck width (AUROC = 0.633, 95% CI 0.574-0.691). The accuracy of fracture discrimination was improved by combining ASM modes with femoral neck bone mineral density (AUROC = 0.835, 95% CI 0.795-0.875) or with intertrochanteric bone mineral density (AUROC = 0.834, 95% CI 0.794-0.875). Hips with positive standard deviations of ASM mode 4 had the highest risk of incident hip fracture (odds ratio = 2.48, 95% CI 1.68-3.31, p < .001). We conclude that variations in the relative size of the femoral head and neck are important determinants of incident hip fracture. The addition of hip shape to fracture-prediction tools may improve the risk assessment for osteoporotic hip fractures. Copyright © 2011 American Society for Bone and Mineral Research.
[A giant myxoid leiomyoma mimicking an inguinal hernia].
Huszár, Orsolya; Zaránd, Attila; Szántó, Gyöngyi; Juhász, Viktória; Székely, Eszter; Novák, András; Molnár, Béla Ákos; Harsányi, László
2016-03-06
Leiomyoma is a rare, smooth muscle tumour that can occur everywhere in the human body. The authors present the history of a 60-year-old female, who had a giant, Mullerian type myxoid leiomyoma in the inguinal region mimicking acute abdominal symptoms. After examination the authors removed the soft tissue mass in the right femoral region reaching down in supine position to the middle third of the leg measuring 335 × 495 × 437 mm in greatest diameters in weight 33 kg. Reconstruction of the tissue defect was performed using oncoplastic guidelines. During the follow-up time no tumour recurrence was detected and the quality of life of the patient improved significantly.
Chung, Chih-Yang; Chang, Yi-Wei; Huang, Chun-Jen; Wang, Po-Kai; Wan, Hung-Chieh; Lin, Yi-Ying; Kao, Ming-Chang
2017-08-24
Ischemia-reperfusion (IR) in the rat femoral artery has been proposed as an experimental model of vasculitic peripheral neuropathy (VPN) which presents neuropathic pain and peripheral nerve injury patterns observed clinically. This study investigates the involvement of the proinflammatory signaling pathway underlying the peripheral mechanisms of VPN. Male Sprague-Dawley rats were allocated to receive either a sham operation or IR. IR was induced by occluding the right femoral artery for 4h followed by reperfusion periods from 0 to 72h. The behavioral parameters were assessed at baseline as well as at days 1, 2 and 3 after reperfusion. The time-course analyses of proinflammatory mediators in the sciatic nerves were also performed on rats of the sham group or IR groups with reperfusion periods of 0, 2, 4, 24 and 72h, respectively. The behavioral data confirmed that this VPN model induced hindpaw mechano-allodynia and heat hyperalgesia as well as impaired hindpaw grip strength. The molecular data revealed that IR in the femoral artery activated the expression of nuclear factor-κB (NF-κB) in the sciatic nerve indicating a neuroinflammatory response. Moreover, IR in the femoral artery increased the expression of proinflammatory cytokines TNF-α and IL-1β in the sciatic nerve. This study elucidated the novel time-course expression profiles of NF-κB and proinflammatory cytokines in VPN induced by IR which may be involved in the development of neuropathic pain. Since NF-κB is a key element during neuroinflammation, strategies targeting the NF-κB signaling pathway may provide therapeutic potential against VPN induced by IR. Copyright © 2017 Elsevier B.V. All rights reserved.
Kim, Harry K W; Aruwajoye, Olumide; Du, Justin; Kamiya, Nobuhiro
2014-09-17
Non-weight-bearing decreases the femoral head deformity but increases bone resorption without increasing bone formation in an experimental animal model of Legg-Calvé-Perthes disease. We sought to determine if local administration of bone morphogenetic protein (BMP)-2 with or without bisphosphonate can increase the bone formation during the non-weight-bearing treatment in the large animal model of Legg-Calvé-Perthes disease. Eighteen piglets were surgically induced with femoral head ischemia. Immediately following the surgery, all animals received an above-the-knee amputation to enforce local non-weight-bearing (NWB). One to two weeks later, six animals received local BMP-2 to the necrotic head (BMP group), six received local BMP-2 and ibandronate (BMP+IB group), and the remaining six received no treatment (NWB group). All animals were killed at eight weeks after the induction of ischemia. Radiographic, microcomputed tomography (micro-CT), and histomorphometric assessments were performed. Radiographic assessment showed that the femoral heads in the NWB, BMP, and BMP+IB groups had a decrease of 20%, 14%, and 10%, respectively, in their mean epiphyseal quotient in comparison with the normal control group. Micro-CT analyses showed significantly higher femoral head bone volume in the BMP+IB group than in the BMP group (p = 0.02) and the NWB group (p < 0.001). BMP+IB and BMP groups had a significantly higher trabecular number (p < 0.01) and lower trabecular separation (p < 0.02) than the NWB group. In addition, the osteoclast number per bone surface was significantly lower in the BMP+IB group compared with the NWB group. Calcein labeling showed significantly higher bone formation in the BMP and BMP+IB groups than in the NWB group (p < 0.05). Heterotopic ossification was found in the capsule of four hips in the BMP+IB group but not in the BMP group. Administration of BMP-2 with bisphosphonate best decreased bone resorption and increased new bone formation during non-weight-bearing treatment of ischemic osteonecrosis in a pig model, but heterotopic ossification is a concern. This preclinical study provides new evidence that BMP-2 with bisphosphonate can effectively prevent the extreme bone loss associated with the non-weight-bearing treatment and increase new bone formation in the femoral head in this animal model of ischemic osteonecrosis. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Yoshioka, Tomokazu; Mishima, Hajime; Sakai, Shinsuke; Uemura, Toshimasa
2013-10-01
The purpose of this study was to evaluate the long-term results of cartilage repair after allogeneic transplantation of cartilaginous aggregates formed from bone marrow-derived cells. Bone marrow cells were harvested from 12-day-old rabbits. The cells were subjected to a monolayer culture, and the spindle-shaped cells attached to the flask surface were defined as bone marrow-derived mesenchymal cells. After the monolayer culture, a 3-dimensional cartilaginous aggregate was formed using a bioreactor with chondrogenesis. We created osteochondral defects, measuring 5 mm in diameter and 4 mm in depth, at the femoral trochlea of 10-week-old rabbits. Two groups were established, the transplanted group in which the cartilaginous aggregate was transplanted into the defect, and the control group in which the defect was left untreated. Twenty-six and 52 weeks after surgery, the rabbits were sacrificed and their tissue repair status was evaluated macroscopically (International Cartilage Repair Society [ICRS] score) and histologically (O'Driscoll score). The ICRS scores were as follows: at week 26, 7.2 ± 0.5 and 7.6 ± 0.8; at week 52, 7.6 ± 1.1 and 9.7 ± 0.7, for the transplanted and control groups, respectively. O'Driscoll scores were as follows: at week 26, 12.6 ± 1.9 and 10.1 ± 1.9; at week 52, 9.6 ± 3.0 and 14.0 ± 1.4, each for transplanted and control groups, respectively. No significant differences were observed between the groups. This study demonstrates that allogeneic transplantation of cartilaginous aggregates formed from bone marrow-derived cells produces comparable long-term results based on macroscopic and histological outcome measures when compared with osteochondral defects that are left untreated.
Characterization of cartilage defects detected by MRI in Kellgren-Lawrence grade 0 or 1 knees.
Taguchi, Kenji; Chiba, Ko; Okazaki, Narihiro; Kido, Yasuo; Miyamoto, Takashi; Yonekura, Akihiko; Tomita, Masato; Uetani, Masataka; Osaki, Makoto
2017-09-01
Osteoarthritis of the knee is generally evaluated by plain X-rays, which are incapable of detecting small cartilage damage. There are some patients who have small cartilage defects on MRI with no abnormal findings on plain X-rays. In this study, the prevalence and regional characteristics of cartilage defects detected by MRI were studied in cases with normal X-ray findings (Kellgren-Lawrence grade 0 and 1). Relationships between the cartilage defects and OA risk factors such as obesity and leg alignment were also investigated. A total of 51 knees of Kellgren-Lawrence grade 0 or 1 without knee joint pain were included. Fat-suppressed spoiled-gradient recalled (SPGR) sagittal images were scanned by 3 T MRI, and the presence of cartilage damage was confirmed. Cartilage damage was visualized three-dimensionally, and its location and morphology were analyzed. On a full length standing radiograph of the lower extremities, leg alignment and other parameters were measured, and their associations with cartilage damage were analyzed. Cartilage defects were detected in 26% of women aged >50 years. Cartilage damage was located on the medial femoral condyle near the intercondylar notch, and was mostly elliptically shaped in the anteroposterior direction. Subjects with damaged cartilage were not obese and did not have abnormal leg alignment. It should be borne in mind that some elderly women may have damaged cartilage on the intercondylar notch side of the medial joint, even though plain X-rays appear normal, and this cannot be predicted by obesity or leg alignment. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Bell, Angela D; Lascau-Coman, Viorica; Sun, Jun; Chen, Gaoping; Lowerison, Mark W; Hurtig, Mark B; Hoemann, Caroline D
2013-04-01
Delivery of chitosan to subchondral bone is a novel approach for augmented marrow stimulation. We evaluated the effect of 3 presolidified chitosan-blood implant formulations on osteochondral repair progression compared with untreated defects. In N = 5 adult sheep, six 2-mm diameter Jamshidi biopsy holes were created bilaterally in the medial femoral condyle and treated with presolidified chitosan-blood implant with fluorescent chitosan tracer (10 kDa, 40 kDa, or 150k Da chitosan, left knee) or left to bleed (untreated, right knee). Implant residency and osteochondral repair were assessed at 1 day (N = 1), 3 weeks (N = 2), or 3 months (N = 2) postoperative using fluorescence microscopy, histomorphometry, stereology, and micro-computed tomography. Chitosan implants were retained in 89% of treated Jamshidi holes up to 3 weeks postoperative. At 3 weeks, biopsy sites were variably covered by cartilage flow, and most bone holes contained cartilage flow fragments and heterogeneous granulation tissues with sparse leukocytes, stromal cells, and occasional adipocytes (volume density 1% to 3%). After 3 months of repair, most Jamshidi bone holes were deeper, remodeling at the edges, filled with angiogenic granulation tissue, and lined with variably sized chondrogenic foci fused to bone trabeculae or actively repairing bone plate. The 150-kDa chitosan implant elicited more subchondral cartilage formation compared with 40-kDa chitosan-treated and control defects (P < 0.05, N = 4). Treated defects contained more mineralized repair tissue than control defects at 3 months (P < 0.05, N = 12). Bone plate-induced chondroinduction is an articular cartilage repair mechanism. Jamshidi biopsy repair takes longer than 3 months and can be influenced by subchondral chitosan-blood implant.
Glatt, Vaida; Bartnikowski, Nicole; Quirk, Nicholas; Schuetz, Michael; Evans, Christopher
2016-01-01
Background: Reverse dynamization is a technology for enhancing the healing of osseous defects. With use of an external fixator, the axial stiffness across the defect is initially set low and subsequently increased. The purpose of the study described in this paper was to explore the efficacy of reverse dynamization under different conditions. Methods: Rat femoral defects were stabilized with external fixators that allowed the stiffness to be modulated on living animals. Recombinant human bone morphogenetic protein-2 (rhBMP-2) was implanted into the defects on a collagen sponge. Following a dose-response experiment, 5.5 μg of rhBMP-2 was placed into the defect under conditions of very low (25.4-N/mm), low (114-N/mm), medium (185-N/mm), or high (254-N/mm) stiffness. Reverse dynamization was evaluated with 2 different starting stiffnesses: low (114 N/mm) and very low (25.4 N/mm). In both cases, high stiffness (254 N/mm) was imposed after 2 weeks. Healing was assessed with radiographs, micro-computed tomography (μCT), histological analysis, and mechanical testing. Results: In the absence of dynamization, the medium-stiffness fixators provided the best healing. Reverse dynamization starting with very low stiffness was detrimental to healing. However, with low initial stiffness, reverse dynamization considerably improved healing with minimal residual cartilage, enhanced cortication, increased mechanical strength, and smaller callus. Histological analysis suggested that, in all cases, healing provoked by rhBMP-2 occurred by endochondral ossification. Conclusions: These data confirm the potential utility of reverse dynamization as a way of improving bone healing but indicate that the stiffness parameters need to be selected carefully. Clinical Relevance: Reverse dynamization may reduce the amount of rhBMP-2 needed to induce healing of recalcitrant osseous lesions, reduce the time to union, and decrease the need for prolonged external fixation. PMID:27098327
Bell, Angela D.; Lascau-Coman, Viorica; Sun, Jun; Chen, Gaoping; Lowerison, Mark W.; Hurtig, Mark B.
2013-01-01
Objective: Delivery of chitosan to subchondral bone is a novel approach for augmented marrow stimulation. We evaluated the effect of 3 presolidified chitosan-blood implant formulations on osteochondral repair progression compared with untreated defects. Design: In N = 5 adult sheep, six 2-mm diameter Jamshidi biopsy holes were created bilaterally in the medial femoral condyle and treated with presolidified chitosan-blood implant with fluorescent chitosan tracer (10 kDa, 40 kDa, or 150k Da chitosan, left knee) or left to bleed (untreated, right knee). Implant residency and osteochondral repair were assessed at 1 day (N = 1), 3 weeks (N = 2), or 3 months (N = 2) postoperative using fluorescence microscopy, histomorphometry, stereology, and micro–computed tomography. Results: Chitosan implants were retained in 89% of treated Jamshidi holes up to 3 weeks postoperative. At 3 weeks, biopsy sites were variably covered by cartilage flow, and most bone holes contained cartilage flow fragments and heterogeneous granulation tissues with sparse leukocytes, stromal cells, and occasional adipocytes (volume density 1% to 3%). After 3 months of repair, most Jamshidi bone holes were deeper, remodeling at the edges, filled with angiogenic granulation tissue, and lined with variably sized chondrogenic foci fused to bone trabeculae or actively repairing bone plate. The 150-kDa chitosan implant elicited more subchondral cartilage formation compared with 40-kDa chitosan-treated and control defects (P < 0.05, N = 4). Treated defects contained more mineralized repair tissue than control defects at 3 months (P < 0.05, N = 12). Conclusion: Bone plate–induced chondroinduction is an articular cartilage repair mechanism. Jamshidi biopsy repair takes longer than 3 months and can be influenced by subchondral chitosan-blood implant. PMID:26069656
Dashtdar, Havva; Rothan, Hussin A; Tay, Terence; Ahmad, Raja Elina; Ali, Razif; Tay, Liang Xin; Chong, Pan Pan; Kamarul, Tunku
2011-09-01
Chondrogenic differentiated mesenchymal stem cells (CMSCs) have been shown to produce superior chondrogenic expression markers in vitro. However, the use of these cells in vivo has not been fully explored. In this study, in vivo assessment of cartilage repair potential between allogenic-derived chondrogenic pre-differentiated mesenchymal stem cells and undifferentiated MSCs (MSCs) were compared. Bilateral full thickness cartilage defects were created on the medial femoral condyles of 12 rabbits (n = 12). Rabbits were divided into two groups. In one group, the defects in the right knees were repaired using alginate encapsulated MSCs while in the second group, CMSCs were used. The animals were sacrificed and the repaired and control knees were assessed at 3 and 6 months after implantation. Quantitative analysis was performed by measuring the Glycosaminoglycans (GAGs)/total protein content. The mean Brittberg score was higher in the transplanted knees as compared to the untreated knee at 6 months (p < 0.05). Quantitative analysis of GAGs was consistent with these results. Histological and immunohistochemical analysis demonstrated hyaline-like cartilage regeneration in the transplanted sites. Significant differences between the histological scores based on O'Driscoll histological grading were observed between contralateral knees at both 3 and 6 months (p < 0.05). No significant differences were observed between the Britberg, O'Driscoll scores, and GAGs/total protein content when comparing defect sites treated with MSC and CMSC (p > 0.05). This study demonstrates that the use of either MSC or CMSC produced superior healing when compared to cartilage defects that were untreated. However, both cells produced comparable treatment outcomes. Copyright © 2011 Orthopaedic Research Society.
Park, Jaeyeong; Kim, Jun-Young; Kim, Hyun Deok; Kim, Young Cheol; Seo, Anna; Je, Minkyu; Mun, Jong Uk; Kim, Bia; Park, Il Hyung; Kim, Shin-Yoon
2017-05-01
Radiographic measurements using two-dimensional (2D) plain radiographs or planes from computed tomography (CT) scans have several drawbacks, while measurements using images of three-dimensional (3D) reconstructed bone models can provide more consistent anthropometric information. We compared the consistency of results using measurements based on images of 3D reconstructed bone models (3D measurements) with those using planes from CT scans (measurements using 2D slice images). Ninety-six of 561 patients who had undergone deep vein thrombosis-CT between January 2013 and November 2014 were randomly selected. We evaluated measurements using 2D slice images and 3D measurements. The images used for 3D reconstruction of bone models were obtained and measured using [Formula: see text] and [Formula: see text] (Materialize, Leuven, Belgium). The mean acetabular inclination, acetabular anteversion and femoral anteversion values on 2D slice images were 42.01[Formula: see text], 18.64[Formula: see text] and 14.44[Formula: see text], respectively, while those using images of 3D reconstructed bone models were 52.80[Formula: see text], 14.98[Formula: see text] and 17.26[Formula: see text]. Intra-rater reliabilities for acetabular inclination, acetabular anteversion, and femoral anteversion on 2D slice images were 0.55, 0.81, and 0.85, respectively, while those for 3D measurements were 0.98, 0.99, and 0.98. Inter-rater reliabilities for acetabular inclination, acetabular anteversion and femoral anteversion on 2D slice images were 0.48, 0.86, and 0.84, respectively, while those for 3D measurements were 0.97, 0.99, and 0.97. The differences between the two measurements are explained by the use of different tools. However, more consistent measurements were possible using the images of 3D reconstructed bone models. Therefore, 3D measurement can be a good alternative to measurement using 2D slice images.
Osaki, Kanji; Okazaki, Ken; Matsubara, Hirokazu; Kuwashima, Umito; Murakami, Koji; Iwamoto, Yukihide
2015-12-01
To investigate the mismatch between the length at the center and the length on the shortest and longest peripheral sides of the femoral tunnel socket, reamed with the transportal (TP), outside-in (OI), and modified transtibial (TT) techniques, in anterior cruciate ligament (ACL) reconstruction. Femoral tunnel drilling was simulated on 3-dimensional bone models from 40 subjects. The tunnel directions used with the TP, OI, and modified TT techniques were previously described. By use of the resulting angle, a femoral tunnel socket of 9 mm in diameter was drilled from the center of the femoral ACL insertion. The virtual femoral tunnel was extracted, and the length mismatch was measured between the center and the shortest and longest peripheral sides of the tunnel socket. The mean socket length mismatch between the center and the shortest peripheral part of the femoral tunnel socket was 4.2 ± 0.9 mm with the TP technique, 5.2 ± 1.3 mm with the OI technique, and 3.2 ± 0.8 mm with the modified TT technique. The mean socket length mismatch between the center and the longest peripheral part of the femoral tunnel socket was 3.5 ± 0.9 mm with the TP technique, 4.8 ± 1.5 mm with the OI technique, and 3.3 ± 1.2 mm with the modified TT technique. The length mismatch was significantly higher when the tunnel socket was created by the OI technique (P < .01). A length mismatch with the tunnel socket exists after reaming with either the TP, OI, or modified TT technique. In particular, there was a significant increase in length mismatch when the tunnel socket was created by the OI technique, and the length mismatch would easily become greater than 5 mm. The surgeon should recognize this mismatch when it is created and measure the femoral tunnel socket. In anatomic ACL reconstruction, a mismatch between the length at the center and the length at periphery of the femoral tunnel socket occurs, and this is increased particularly when using the OI technique. The discrepancy in tunnel length between its center and its periphery could cause an overestimation of the tunnel length that could result in an error in length during graft preparation. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Sirleo, Luigi; Innocenti, Massimo; Innocenti, Matteo; Civinini, Roberto; Carulli, Christian; Matassi, Fabrizio
2018-02-01
To evaluate the feedback from post-operative three-dimensional computed tomography (3D-CT) on femoral tunnel placement in the learning process, to obtain an anatomic anterior cruciate ligament (ACL) reconstruction. A series of 60 consecutive patients undergoing primary ACL reconstruction using autologous hamstrings single-bundle outside-in technique were prospectively included in the study. ACL reconstructions were performed by the same trainee-surgeon during his learning phase of anatomic ACL femoral tunnel placement. A CT scan with dedicated tunnel study was performed in all patients within 48 h after surgery. The data obtained from the CT scan were processed into a three-dimensional surface model, and a true medial view of the lateral femoral condyle was used for the femoral tunnel placement analysis. Two independent examiners analysed the tunnel placements. The centre of femoral tunnel was measured using a quadrant method as described by Bernard and Hertel. The coordinates measured were compared with anatomic coordinates values described in the literature [deep-to-shallow distance (X-axis) 28.5%; high-to-low distance (Y-axis) 35.2%]. Tunnel placement was evaluated in terms of accuracy and precision. After each ACL reconstruction, results were shown to the surgeon to receive an instant feedback in order to achieve accurate correction and improve tunnel placement for the next surgery. Complications and arthroscopic time were also recorded. Results were divided into three consecutive series (1, 2, 3) of 20 patients each. A trend to placing femoral tunnel slightly shallow in deep-to-shallow distance and slightly high in high-to-low distance was observed in the first and the second series. A progressive improvement in tunnel position was recorded from the first to second series and from the second to the third series. Both accuracy (+52.4%) and precision (+55.7%) increased from the first to the third series (p < 0.001). Arthroscopic time decreased from a mean of 105 min in the first series to 57 min in the third series (p < 0.001). After 50 ACL reconstructions, a satisfactory anatomic femoral tunnel was reached. Feedback from post-operative 3D-CT is effective in the learning process to improve accuracy and precision of femoral tunnel placement in order to obtain anatomic ACL reconstruction and helps to reduce also arthroscopic time and learning curve. For clinical relevance, trainee-surgeons should use feedback from post-operative 3DCT to learn anatomic ACL femoral tunnel placement and apply it appropriately. Consecutive case series, Level IV.
Novel Model of Somatosensory Nerve Transfer in the Rat.
Paskal, Adriana M; Paskal, Wiktor; Pelka, Kacper; Podobinska, Martyna; Andrychowski, Jaroslaw; Wlodarski, Pawel K
2018-05-09
Nerve transfer (neurotization) is a reconstructive procedure in which the distal denervated nerve is joined with a proximal healthy nerve of a less significant function. Neurotization models described to date are limited to avulsed roots or pure motor nerve transfers, neglecting the clinically significant mixed nerve transfer. Our aim was to determine whether femoral-to-sciatic nerve transfer could be a feasible model of mixed nerve transfer. Three Sprague Dawley rats were subjected to unilateral femoral-to-sciatic nerve transfer. After 50 days, functional recovery was evaluated with a prick test. At the same time, axonal tracers were injected into each sciatic nerve distally to the lesion site, to determine nerve fibers' regeneration. In the prick test, the rats retracted their hind limbs after stimulation, although the reaction was moderately weaker on the operated side. Seven days after injection of axonal tracers, dyes were visualized by confocal microscopy in the spinal cord. Innervation of the recipient nerve originated from higher segments of the spinal cord than that on the untreated side. The results imply that the femoral nerve axons, ingrown into the damaged sciatic nerve, reinnervate distal targets with a functional outcome.
Chen, Weng-Pin; Tai, Ching-Lung; Tan, Chih-Feng; Shih, Chun-Hsiung; Hou, Shun-Hsin; Lee, Mel S
2005-01-01
Transtrochanteric rotational osteotomy is a technical demanding procedure. Currently, the pre-operative planning of the transtrochanteric rotational osteotomy is mostly based on X-ray images. The surgeons would need to reconstruct the three-dimensional structure of the femoral head and the necrosis in their mind. This study develops a simulation platform using computer models based on the computed tomography images of the femoral head to evaluate the degree to which transtrochanteric rotational osteotomy moves the region of osteonecrotic femoral head out of the weight-bearing area in stance and gait cycle conditions. Based on this simulation procedure, the surgeons would be better informed before the surgery and the indication can be carefully assessed. A case with osteonecrosis involving 15% of the femoral head was recruited. Virtual models with the same size lesion but at different locations were devised. Computer models were created using SolidWorks 2000 CAD software. The area ratio of weight-bearing zone occupied by the necrotic lesion on two conditions, stance and gait cycle, were measured after surgery simulations. For the specific case and virtual models devised in this study, computer simulation showed the following two findings: (1) The degrees needed to move the necrosis out of the weight-bearing zone in stance were less by anterior rotational osteotomy as compared to that of posterior rotational osteotomy. However, the necrotic region would still overlap with the weight-bearing area during gait cycle. (2) Because the degrees allowed for posterior rotation were less restricted than anterior rotation, posterior rotational osteotomies were often more effective to move the necrotic region out of the weight-bearing area during gait cycle. The computer simulation platform by registering actual CT images is a useful tool to assess the direction and degrees needed for transtrochanteric rotational osteotomy. Although the results indicated that anterior rotational osteotomy was more effective to move the necrosis out of the weight-bearing zone in stance for models devised in this study, in circumstances where the necrotic region located at various locale, considering the limitation of anterior rotation inherited with the risk of vascular compromise, it might be more beneficial to perform posterior rotation osteotomy in taking account of gait cycle.
Cerebrovascular Damage Mediates Relations Between Aortic Stiffness and Memory.
Cooper, Leroy L; Woodard, Todd; Sigurdsson, Sigurdur; van Buchem, Mark A; Torjesen, Alyssa A; Inker, Lesley A; Aspelund, Thor; Eiriksdottir, Gudny; Harris, Tamara B; Gudnason, Vilmundur; Launer, Lenore J; Mitchell, Gary F
2016-01-01
Aortic stiffness is associated with cognitive decline. Here, we examined the association between carotid-femoral pulse wave velocity and cognitive function and investigated whether cerebrovascular remodeling and parenchymal small vessel disease damage mediate the relation. Analyses were based on 1820 (60% women) participants in the Age, Gene/Environment Susceptibility-Reykjavik Study. Multivariable linear regression models adjusted for vascular and demographic confounders showed that higher carotid-femoral pulse wave velocity was related to lower memory score (standardized β: -0.071±0.023; P=0.002). Cerebrovascular resistance and white matter hyperintensities were each associated with carotid-femoral pulse wave velocity and memory (P<0.05). Together, cerebrovascular resistance and white matter hyperintensities (total indirect effect: -0.029; 95% CI, -0.043 to -0.017) attenuated the direct relation between carotid-femoral pulse wave velocity and memory (direct effect: -0.042; 95% CI, -0.087 to 0.003; P=0.07) and explained ≈41% of the observed effect. Our results suggest that in older adults, associations between aortic stiffness and memory are mediated by pathways that include cerebral microvascular remodeling and microvascular parenchymal damage. © 2015 American Heart Association, Inc.
Song, Weiye; Zhou, Libo; Kot, Kevin Liu; Fan, Huijie; Han, Jingyan; Yi, Ji
2018-05-31
Flow-mediated vasodilation (FMD) is used for assessment of vascular endothelial function in humans as a predictor of cardiovascular events. It has been challenging to carry it on preclinical murine models due to the diminutive size of the femoral artery. Here, we present a new approach to accurately measure the blood velocity and femoral artery diameters of mice by acquiring Doppler optical coherence tomography (DOCT) and optical coherence tomography angiography (OCTA) continuously within one single experimental scanning protocol. Using the high precision three-dimensional imaging and new velocity algorithm, the measurement precision of diameter, blood flow, velocity, and wall shear stress are improved to 0.91%, 11.0%, 10.7%, and 14.0%, respectively. FMD of healthy mouse femoral artery measured by this method was 11.96 ± 0.98%, which was blunted to 5.69±0.4% by intravenous administration of eNOS inhibitor (L-NAME), in agreement with that reported in the literature. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Anatomical and biomechanical investigations of the iliotibial tract.
Birnbaum, K; Siebert, C H; Pandorf, T; Schopphoff, E; Prescher, A; Niethard, F U
2004-12-01
Divergent descriptions of the anatomic location and biomechanical function of the iliotibial tract (IT) can be found in the literature. This study attempted to obtain exact data regarding the anatomic course and material characteristics including the biomechanical properties of this structure. The following were its aims: (1) anatomical investigations of the IT; (2) mechanical properties of the IT; (3) femoral head centralizing force of the IT and subligamentous forces in the height of the greater trochanter in different joint positions by using a custom-made measuring prosthesis and a subligamentous positioned sensor; (4) construction of a finite element model of the proximal femur including the IT and measuring the femoral neck angle under variation. The hip joints and IT in a total of 18 unfixed corpses were evaluated. We studied the anatomic relationship to surrounding structures, as well as the material properties with the help of tensile strength testing utilizing an uniaxial apparatus. During the test, a load-displacement curve was registered, documenting the maximum load and deformation of the IT. To measure the subligamentous pressure at the height of the greater trochanter, a custom-made sensor with a power-recording instrument was constructed. Furthermore, an altered hip prosthesis with a pressure gauge at the height of the femoral neck was used to measure the forces which are directed at the acetabulum. The investigations were done in neutral-0 position and ab/adduction of the hip joint of the unfixed corpse. In addition, we varied the femoral neck angle between 115 degrees and 155 degrees in 5 degrees steps. To confirm the subligamentous forces, we did the same measurements intraoperatively at the height of the greater trochanter before and after hip joint replacement in 12 patients. We constructed a finite element model of the proximal femur and considering the IT. The acquisition of the data was done at physiological (128 degrees), varus (115 degrees), and valgus (155 degrees) femoral neck angles. The influencing forces of the IT at the height of the greater trochanter and the forces at the femoral head or the acetabulum could be measured. Our anatomical investigations revealed a splitting of the IT into a superficial and a deep portion, which covers the tensor fasciae latae. The tensor fasciae latae has an insertion on the IT. The IT continues down the femur, passing over the greater trochanter without developing an actual fixation to the bone. Part of the insertion of the gluteus maximus radiates into the IT. The IT passes over the vastus lateralis and inserts at the infracondylar tubercle of the tibia or Gerdy's tubercle, at the head of the fibula, as well as at the lateral intermuscular septum. Portions also insert on the transverse and longitudinal retinaculum of the patella. Concerning the material properties of the IT, we found a structural stiffness of 17 N/mm extension on average (D = 17 N/mm). The subligamentous measurements at the height of the greater trochanter in the unfixed corpse and intraoperatively during hip joint replacement showed an increase of the forces during adduction and a decrease during abduction of the hip joint. We found thereby a maximum increase up to 106 N with 40 degrees adduction. Concerning the femoral neck angle, we can state that valgus leads to lower subligamentous forces and varus to higher subligamentous forces. The forces directed at the acetabulum, which were measured by the prosthesis with a sensor along the femoral neck, showed a decrease with varus angles and an increase with valgus angles. The highest force of 624 N was measured with 40 degrees adduction and an angle of 155 degrees. The finite element model of the proximal femur showed a sole hip joint-centralizing force of the IT of 655 N with a femoral neck angle of 128 degrees after subtraction of the gluteal muscle force and the body weight. At 115 degrees, we found an increase up to 997 N and a decrease to 438 N at 155 degrees. Concerning the resulting forces in the acetabulum, we found opposite forces in comparison with the force of the IT at the height of the greater trochanter: at 115 degrees, a femoral head-centralizing force of 1601 N; at 128 degrees, 2360 N; and at 155 degrees, 2422 N. By our investigations, we can approximately prove the hip joint-centralizing force of the IT. By variation of the femoral neck angle and the position of the hip joint, we can predict the subligamentous force of the IT and the resulting force at the femoral head or at the acetabulum. The intraoperative measurement of the subligamentous forces of the IT is a good monitoring mechanism for the persistent hip-centralizing function of the IT in the course of hip joint replacement. The surgeon has the opportunity to check the stability of the hip joint after replacement. The finite element model gives the opportunity to check the divergent relative strength by variation of the femoral neck angle and the tension of the IT. In this way, the changes in the forces induced by a displacement osteotomy could be estimated preoperatively.
Femoral head asymmetry and coxa magna: anatomic study.
Young, Ernest Y; Gebhart, Jeremy J; Bajwa, Navkirat; Cooperman, Daniel R; Ahn, Nicholas U
2014-06-01
Coxa magna, the asymmetrical circumferential enlargement of the femoral head, is an important sequela of pediatric disorders such as Legg-Calvé-Perthes disease. Definitions vary because of lack of controls and a scarcity of research on the distribution of the femoral head asymmetry. This study aims at defining the normal distribution of asymmetry between the left and the right femoral head and neck in the population and how demographics affect these properties. The study also looked at the distribution of side dominance (left or right). This study measured 230 paired femurs from individuals (20 to 40 y old) distributed for sex and ethnicity. The height and weight of the individuals were also recorded. The femoral head diameter and minimal femoral neck diameter in the anteroposterior view were measured on each paired femurs. The absolute and percent differences were determined to define asymmetry. Most of the population fell within 3% of asymmetry for the femoral head and 4% for the femoral neck. The maximum head percent asymmetry was 7.4%. Absolute difference in millimeters to percent asymmetry showed a ratio of 2:1 for the femoral head and 3:1 for the femoral neck. African Americans showed greater femoral head symmetry and a bias toward left-sided femoral head and neck enlargement when compared with their white counterparts. There was a high degree of symmetry between the left and right femoral heads and necks, which supports definitions found in the literature that define coxa magna above 10%. This study defines asymmetry in the femoral head in the normal population, which will help to define a quantitative definition of coxa magna.
Tuberculosis of hip in children: A retrospective analysis
Moon, Myung-Sang; Kim, Sung-Soo; Lee, Sung-Rak; Moon, Young-Wan; Moon, Jeong-Lim; Moon, Seog-In
2012-01-01
Background: Tuberculosis (TB) of hip constitutes nearly 15% of all cases of osteoarticular tuberculosis. We report a retrospective study carried out on 43 children with hip TB. Materials and Methods: Forty-three children of TB hip treated between 1971 and 2000 were analysed. Twenty-four children of the early series were treated with streptomycin (S), isoniazid (H) and PAS (Pa) for 18 months (3HPaS, 15 HPa), while 19 children in the later series were treated with isoniazid (H), rifampicin (R) and ethambutol (E) or pyrazinamide (Z) for 12 months [(12 RHE(Z)]. Five out of 18 children with radiologically normal appearing type hip TB were treated with chemotherapy alone and 38 children were subjected to surgery; simple synovectomy alone in 31 hips, joint debridement in six hips, and proximal femoral varisation osteotomy in one. After surgery hips were immobilized in cast for one to three months according to the severity of the disease and patients pain tolerance, and then were mobilized under leg traction in bed gradually till pain subsided completely. Results: TB of hip healed with minimum sequelae in all children. In 18 Type one hip TB, normal hip (synovial form) anatomy was maintained, and in 25 patients with advanced lesions some defect in the femoral head and acetabulum was noticed, though painless good hip motion was maintained. Excellent to good results were obtained in 31 children (73.1%), fair in eight (18.6%), and poor in four (9.3%). In four patients with poor results, there was some residual morphological defect in the hip. None developed ankylosis of hip. Conclusion: We achieved good outcome with minimum sequelae in this series. The management goal should be aimed not only to heal the disease but also to maintain a painless mobile hip and anatomical cephalocotyloid relationship until maturity, and retard the development of secondary osteoarthritis. PMID:22448058
Chitosan porous 3D scaffolds embedded with resolvin D1 to improve in vivo bone healing.
Vasconcelos, Daniela P; Costa, Madalena; Neves, Nuno; Teixeira, José H; Vasconcelos, Daniel M; Santos, Susana G; Águas, Artur P; Barbosa, Mário A; Barbosa, Judite N
2018-06-01
The aim of this study was to investigate the effect chitosan (Ch) porous 3D scaffolds embedded with resolvin D1 (RvD1), an endogenous pro-resolving lipid mediator, on bone tissue healing. These scaffolds previous developed by us have demonstrated to have immunomodulatory properties namely in the modulation of the macrophage inflammatory phenotypic profile in an in vivo model of inflammation. Herein, results obtained in an in vivo rat femoral defect model demonstrated that two months after Ch + RvD1 scaffolds implantation, an increase in new bone formation, in bone trabecular thickness, and in collagen type I and Coll I/Coll III ratio were observed. These results suggest that Ch scaffolds embedded with RvD1 were able to lead to the formation of new bone with improvement of trabecular thickness. This study shows that the presence of RvD1 in the acute phase of the inflammatory response to the implanted biomaterial had a positive role in the subsequent bone tissue repair, thus demonstrating the importance of innovative approaches for the control of immune responses to biomedical implants in the design of advanced strategies for regenerative medicine. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1626-1633, 2018. © 2018 Wiley Periodicals, Inc.
Shen, Jia; James, Aaron W.; Zhang, Xinli; Pang, Shen; Zara, Janette N.; Asatrian, Greg; Chiang, Michael; Lee, Min; Khadarian, Kevork; Nguyen, Alan; Lee, Kevin S.; Siu, Ronald K.; Tetradis, Sotirios; Ting, Kang; Soo, Chia
2017-01-01
The differentiation factor NEL-like molecule-1 (NELL-1) has been reported as osteoinductive in multiple in vivo preclinical models. Bone morphogenetic protein (BMP)-2 is used clinically for skeletal repair, but in vivo administration can induce abnormal, adipose-filled, poor-quality bone. We demonstrate that NELL-1 combined with BMP2 significantly optimizes osteogenesis in a rodent femoral segmental defect model by minimizing the formation of BMP2-induced adipose-filled cystlike bone. In vitro studies using the mouse bone marrow stromal cell line M2-10B4 and human primary bone marrow stromal cells have confirmed that NELL-1 enhances BMP2-induced osteogenesis and inhibits BMP2-induced adipogenesis. Importantly, the ability of NELL-1 to direct BMP2-treated cells toward osteogenesis and away from adipogenesis requires intact canonical Wnt signaling. Overall, these studies establish the feasibility of combining NELL-1 with BMP2 to improve clinical bone regeneration and provide mechanistic insight into canonical Wnt pathway activity during NELL-1 and BMP2 osteogenesis. The novel abilities of NELL-1 to stimulate Wnt signaling and to repress adipogenesis may highlight new treatment approaches for bone loss in osteoporosis. PMID:26772960
Manunta, Andrea Fabio; Zedde, Pietro; Pilicchi, Susanna; Rocca, Stefano; Pool, Roy R; Dattena, Maria; Masala, Gerolamo; Mara, Laura; Casu, Sara; Sanna, Daniela; Manunta, Maria Lucia; Passino, Eraldo Sanna
2016-01-01
the aim of this study was to determine whether local delivery of embryonic stem-like (ESL) cells into osteochondral defects in the femoral condyles of sheep would enhance regeneration of hyaline articular cartilage. male ESL cells embedded in fibrin glue were engrafted into osteochondral defects in the medial condyles (ESL-M) of the left femur in 22 ewes. An identical defect was created in the medial condyle of the contralateral stifle joint and left untreated as a control (empty defect, ED). The ewes were divided into 5 groups. Four sheep each were euthanized at 1, 2, 6, and 12 months from surgery, and 6 ewes were euthanized 24 months post-implantation. To study the effect of varying loads on the long-term regeneration process, an identical defect was also created and ESL cell engraftment performed in the lateral condyle (ESL-L) of the left stifle joint of the animals in the 12- and 24-month groups. The evaluation of regenerated tissue was performed by biomechanical, macroscopic, histological, immunohistochemical (collagen type II) and fluorescent in situ hybridization (FISH) assays. no significant differences were found between treated and control sites in the biomechanical assays at any time point. ESL cell grafts showed significantly greater macroscopic evidence of regeneration as compared to controls at 24 months after surgery; significantly better histological evidence of repair in ESL-M samples versus controls was found throughout the considered period. At 24 months from surgery there was significantly improved integration of graft edges with the host tissue in the ESL-M as compared to the ESL-L samples, demonstrating that load bearing positively affects the long-term regeneration process. ESL cells enhanced the regeneration of hyaline cartilage. FISH confirmed that the regenerative tissue originated from ESL cells. ESL cells are able to self-renew for prolonged periods without differentiation and, most importantly, to differentiate into a large variety of tissues.
MANUNTA, ANDREA FABIO; ZEDDE, PIETRO; PILICCHI, SUSANNA; ROCCA, STEFANO; POOL, ROY R.; DATTENA, MARIA; MASALA, GEROLAMO; MARA, LAURA; CASU, SARA; SANNA, DANIELA; MANUNTA, MARIA LUCIA; PASSINO, ERALDO SANNA
2016-01-01
Purpose the aim of this study was to determine whether local delivery of embryonic stem-like (ESL) cells into osteochondral defects in the femoral condyles of sheep would enhance regeneration of hyaline articular cartilage. Methods male ESL cells embedded in fibrin glue were engrafted into osteochondral defects in the medial condyles (ESL-M) of the left femur in 22 ewes. An identical defect was created in the medial condyle of the contralateral stifle joint and left untreated as a control (empty defect, ED). The ewes were divided into 5 groups. Four sheep each were euthanized at 1, 2, 6, and 12 months from surgery, and 6 ewes were euthanized 24 months post-implantation. To study the effect of varying loads on the long-term regeneration process, an identical defect was also created and ESL cell engraftment performed in the lateral condyle (ESL-L) of the left stifle joint of the animals in the 12- and 24-month groups. The evaluation of regenerated tissue was performed by biomechanical, macroscopic, histological, immunohistochemical (collagen type II) and fluorescent in situ hybridization (FISH) assays. Results no significant differences were found between treated and control sites in the biomechanical assays at any time point. ESL cell grafts showed significantly greater macroscopic evidence of regeneration as compared to controls at 24 months after surgery; significantly better histological evidence of repair in ESL-M samples versus controls was found throughout the considered period. At 24 months from surgery there was significantly improved integration of graft edges with the host tissue in the ESL-M as compared to the ESL-L samples, demonstrating that load bearing positively affects the long-term regeneration process. Conclusions ESL cells enhanced the regeneration of hyaline cartilage. FISH confirmed that the regenerative tissue originated from ESL cells. Clinical Relevance ESL cells are able to self-renew for prolonged periods without differentiation and, most importantly, to differentiate into a large variety of tissues. PMID:27602346
Glatt, Vaida; Bartnikowski, Nicole; Quirk, Nicholas; Schuetz, Michael; Evans, Christopher
2016-04-20
Reverse dynamization is a technology for enhancing the healing of osseous defects. With use of an external fixator, the axial stiffness across the defect is initially set low and subsequently increased. The purpose of the study described in this paper was to explore the efficacy of reverse dynamization under different conditions. Rat femoral defects were stabilized with external fixators that allowed the stiffness to be modulated on living animals. Recombinant human bone morphogenetic protein-2 (rhBMP-2) was implanted into the defects on a collagen sponge. Following a dose-response experiment, 5.5 μg of rhBMP-2 was placed into the defect under conditions of very low (25.4-N/mm), low (114-N/mm), medium (185-N/mm), or high (254-N/mm) stiffness. Reverse dynamization was evaluated with 2 different starting stiffnesses: low (114 N/mm) and very low (25.4 N/mm). In both cases, high stiffness (254 N/mm) was imposed after 2 weeks. Healing was assessed with radiographs, micro-computed tomography (μCT), histological analysis, and mechanical testing. In the absence of dynamization, the medium-stiffness fixators provided the best healing. Reverse dynamization starting with very low stiffness was detrimental to healing. However, with low initial stiffness, reverse dynamization considerably improved healing with minimal residual cartilage, enhanced cortication, increased mechanical strength, and smaller callus. Histological analysis suggested that, in all cases, healing provoked by rhBMP-2 occurred by endochondral ossification. These data confirm the potential utility of reverse dynamization as a way of improving bone healing but indicate that the stiffness parameters need to be selected carefully. Reverse dynamization may reduce the amount of rhBMP-2 needed to induce healing of recalcitrant osseous lesions, reduce the time to union, and decrease the need for prolonged external fixation. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Dupont, Kenneth M; Boerckel, Joel D; Stevens, Hazel Y; Diab, Tamim; Kolambkar, Yash M; Takahata, Masahiko; Schwarz, Edward M; Guldberg, Robert E
2012-03-01
Biomaterial scaffolds functionalized to stimulate endogenous repair mechanisms via the incorporation of osteogenic cues offer a potential alternative to bone grafting for the treatment of large bone defects. We first quantified the ability of a self-complementary adeno-associated viral vector encoding bone morphogenetic protein 2 (scAAV2.5-BMP2) to enhance human stem cell osteogenic differentiation in vitro. In two-dimensional culture, scAAV2.5-BMP2-transduced human mesenchymal stem cells (hMSCs) displayed significant increases in BMP2 production and alkaline phosphatase activity compared with controls. hMSCs and human amniotic-fluid-derived stem cells (hAFS cells) seeded on scAAV2.5-BMP2-coated three-dimensional porous polymer Poly(ε-caprolactone) (PCL) scaffolds also displayed significant increases in BMP2 production compared with controls during 12 weeks of culture, although only hMSC-seeded scaffolds displayed significantly increased mineral formation. PCL scaffolds coated with scAAV2.5-BMP2 were implanted into critically sized immunocompromised rat femoral defects, both with or without pre-seeding of hMSCs, representing ex vivo and in vivo gene therapy treatments, respectively. After 12 weeks, defects treated with acellular scAAV2.5-BMP2-coated scaffolds displayed increased bony bridging and had significantly higher bone ingrowth and mechanical properties compared with controls, whereas defects treated with scAAV2.5-BMP2 scaffolds pre-seeded with hMSCs failed to display significant differences relative to controls. When pooled, defect treatment with scAAV2.5-BMP2-coated scaffolds, both with or without inclusion of pre-seeded hMSCs, led to significant increases in defect mineral formation at all time points and increased mechanical properties compared with controls. This study thus presents a novel acellular bone-graft-free endogenous repair therapy for orthotopic tissue-engineered bone regeneration.
Lai, Davy; Chen, Chuan-Mu; Chiu, Fang-Yao; Chang, Ming-Chau; Chen, Tain-Hsiung
2007-01-01
We evaluate the effect of reconstructing huge defects (mean, 15.8 cm) of the distal femur with Ilizarov's distraction osteogenesis and free twin-barreled vascularized fibular bone graft (TVFG). We retrospectively reviewed a consecutive series of five patients who had cases of distal femoral fractures with huge defects and infection that were treated by the Ilizarov's distraction osteogenesis. After radical debridement, two of the five cases had free TVFG and monolocal distraction osteogenesis, and another two cases had multilocal distraction osteogenesis with knee fusion because of loss of the joint congruity. The other case with floating knee injury had bilocal distraction osteogenesis and a preserved knee joint. The mean defect of distal femur was 15.8 cm (range, 14-18 cm) in length. The mean length of distraction osteogenesis by Ilizarov's apparatus was 8.2 cm. The mean length of TVFG was 8 cm. The average duration from application of Ilizarov's apparatus to achievement of bony union was 10.2 months (range, 8-13 months). At the end of the follow-up, ranges of motion of three knees were 0 to 45 degrees, 0 to 60 degrees, and 0 to 90 degrees. Two cases had knee arthrodesis with bony fusion because of loss of the joint congruity. There were no leg length discrepancies in all five patients. In addition, three patients had pin tract infections and one case had a 10 degree varus deformity of the femur. Juxta-articular huge defect (>10 cm) of distal femur remains a challenge to orthopedic surgeons. Ilizarov's technique provides the capability to maintain stability, eradicate infection, restore leg length, and to perform adjuvant reconstructive procedure easily. In this study, we found that combining Ilizarov's distraction osteogenesis with TVFG results in improved patient outcome for patients with injuries such as supracondylar or intercondylar infected fractures or nonunion of distal femur with huge bone defect.
Zhang, Wei; Zhu, Feng; Dong, Hanqing; Xu, Yaozeng
2016-04-01
To our knowledge, the type of combination of ipsilateral femoral neck and sub-trochanteric fracture is rare. And the long term follow-up is seldom been reported. A 60 year old woman suffered from a traffic accident. We gave her the intramedullary nail treatment for the combination of ipsilateral femoral neck and sub-trochanteric fracture, and the fracture indeed cured after one year and there is no clue of necrosis of the femoral head, but after 5 years, there is an evidence of necrosis of the femoral head. Combination of ipsilateral femoral neck and sub-trochanteric fracture should be kept in mind. Patients with this unusual fracture should be kept under surveillance for longer than might be thought currently to be necessary for there is a possibility of necrosis of the femoral head, even a nondisplaced femoral neck fracture.
Mechanism of chlorogenic acid treatment on femoral head necrosis and its protection of osteoblasts.
Zhang, Mingjuan; Hu, Xianda
2016-07-01
The aim of the present study was to investigate the therapeutic effect of chlorogenic acid on hormonal femoral head necrosis and its protection of osteoblasts. The study established a femoral head necrosis model in Wistar rats using Escherichia coli endotoxin and prednisolone acetate. The rats were divided into five groups and were treated with different concentrations of chlorogenic acid (1, 10 and 20 mg/kg). The main detected indicators were the blood rheology, bone mineral density, and the hydroxyproline and hexosamine (HOM) contents. At a cellular level, osteoblasts were cultured and treated by drug-containing serum. Subsequently, cell proliferation and the osteoblast cycle were measured using flow cytometry, and the protein expression levels of Bax and B-cell lymphoma 2 (Bcl-2) were detected using western blotting. Chlorogenic acid at a concentration of 20 mg/kg (high-dose) enhanced the bone mineral density of the femoral head and femoral neck following ischemia. Simultaneously, blood flow following the injection of prednisolone acetate was significantly improved, and the HOM contents of the high-dose chlorogenic acid group were significantly different. The results from the flow cytometry analysis indicated that chlorogenic acid can efficiently ameliorate hormone-induced necrosis. The osteoblasts were isolated and cultured. The MTT colorimetric assay showed that chlorogenic acid at different densities can increase the proliferation capabilities of osteoblasts and accelerate the transition process of G 0 /G 1 phase to S phase, as well as enhance mitosis and the regeneration of osteoblasts. Western blotting detection indicated that chlorogenic acid may prohibit the decrease of Bcl-2 and the increase of Bax during apoptosis, thereby inhibiting osteoblast apoptosis and preventing the deterioration of femoral head necrosis. In conclusion, chlorogenic acid at the density of 20 mg/kg is effective in the treatment of hormonal femoral head necrosis, which may be applicable for future treatment.
Szuper, Kinga; Schlégl, Ádám Tibor; Leidecker, Eleonóra; Vermes, Csaba; Somoskeöy, Szabolcs; Than, Péter
2015-03-01
The anatomy and biomechanics of the pelvis and lower limbs play a key role in the development of orthopaedic disorders. This study aimed to establish normal reference standards for the measurement of gender-specific pelvic and femoral parameters in children and adolescents with the EOS 2-D/3-D system. EOS 2-D images of 508 individuals (ages 4-16 years) were obtained as part of routine diagnostics. Patients with lower limb abnormalities were excluded. Pelvic and femoral surface 3-D models were generated and clinical parameters calculated by sterEOS 3-D reconstruction software. Data were evaluated using Spearman correlation, paired-samples and independent-samples t-test and linear regression analysis. Changes in anatomical parameters were found to correlate with age and gender in 1) femoral mechanical axis length: 27.3-43.7 cm (males), 25.5-41.2 cm (females), 2) femoral head diameter: 29.4-46.1 mm (males), 27.7-41.3 mm (females), 3) femoral offset: 26.8-42.4 mm (males), 25.5-37.9 mm (females) and 4) femoral neck length: 35.1-52.9 mm (males), 32.8-48.1 mm (females). There was no gender-specific correlation for the neck shaft angle with values from 130.4° to 129.3°, for femoral torsion (22.5°-19.4°), for sacral slope (39.0°-44.4°) and for lateral pelvic tilt (5.1 mm-6.2 mm). Sagittal pelvic tilt exhibited no significant correlation with age showing average values of 6.5°. The EOS 2-D/3-D system proved to be a valuable method in the evaluation of female and male developmental changes in pelvic and lower limb anatomical parameters, in normal individuals younger than 16 years of age.
Use of routine clinical multimodality imaging in a rabbit model of osteoarthritis--part I.
Bouchgua, M; Alexander, K; d'Anjou, M André; Girard, C A; Carmel, E Norman; Beauchamp, G; Richard, H; Laverty, S
2009-02-01
To evaluate in vivo the evolution of osteoarthritis (OA) lesions temporally in a rabbit model of OA with clinically available imaging modalities: computed radiography (CR), helical single-slice computed tomography (CT), and 1.5 tesla (T) magnetic resonance imaging (MRI). Imaging was performed on knees of anesthetized rabbits [10 anterior cruciate ligament transection (ACLT) and contralateral sham joints and six control rabbits] at baseline and at intervals up to 12 weeks post-surgery. Osteophytosis, subchondral bone sclerosis, bone marrow lesions (BMLs), femoropatellar effusion and articular cartilage were assessed. CT had the highest sensitivity (90%) and specificity (91%) to detect osteophytes. A significant increase in total joint osteophyte score occurred at all time-points post-operatively in the ACLT group alone. BMLs were identified and occurred most commonly in the lateral femoral condyle of the ACLT joints and were not identified in the tibia. A significant increase in joint effusion was present in the ACLT joints until 8 weeks after surgery. Bone sclerosis or cartilage defects were not reliably assessed with the selected imaging modalities. Combined, clinically available CT and 1.5 T MRI allowed the assessment of most of the characteristic lesions of OA and at early time-points in the development of the disease. However, the selected 1.5 T MRI sequences and acquisition times did not permit the detection of cartilage lesions in this rabbit OA model.
NASA Astrophysics Data System (ADS)
Blaber, Elizabeth; Almeida, Eduardo; Grigoryan, Eleonora; Globus, Ruth
Scientific understanding of the effects of microgravity on mammalian physiology has been limited to short duration spaceflight experiments (10-15 days). As long duration and inter-planetary missions are being initiated, there is a great need to understand the long-term effects of spaceflight on various physiological processes, including stem cell-based tissue regeneration. Bion-M1, for the first time, enabled the possibility of studying the effects of 30-days of microgravity exposure on a mouse model with sufficient sample size to enable statistical analysis. In this experiment, we hypothesized that microgravity negatively impacts stem cell based tissue regeneration, such as bone remodeling and regeneration from hematopoietic and mesenchymal precursors, thereby resulting in tissue degeneration in mice exposed to spaceflight. To test this hypothesis we collected the pelvis and proximal femur from space-flown mice and asynchronous ground controls and analyzed bone and bone marrow using techniques including Microcomputed Tomography (MicroCT), and in-vitro differentiation and differentiating cell motility assays. To determine the effects of 30-days spaceflight on bone tissue mass, we used MicroCT to analyze the trabecular bone of the femoral head and the cortical bone of the femoral neck and mid-shaft. We found that spaceflight caused a 45% decrease in bone volume ratio, a 17% decrease in trabecular thickness, a 25% decrease in trabecular number, and a 17% increase in trabecular spacing of trabecular bone. Furthermore, structural model index and trabecular pattern factor were increased by 32% and 82% respectively indicating that 30-days spaceflight resulted not only in a large loss of trabecular bone but also in a decrease of bone strength indicators. Analysis of the femoral neck cortical bone showed an increase in marrow area and cortical porosity indicating an overall widening of the femoral neck. Interestingly, no significant alterations were found in the cortical bone of the femoral mid-shaft. To determine the regenerative potential of osteoblasts derived from mesenchymal stem cells flown in microgravity we conducted post-flight in-vitro osteoblastogenesis and mineralized nodule formation assays. We found an increase in post-flight differentiation and mineralization of microgravity-flown osteogenic cells, suggesting an accumulation of precursor cells that fail to fully differentiate in space, and then resume vigorous osteogenesis upon reloading at 1g. Overall, these preliminary results indicate that exposure to 30-days spaceflight causes significant trabecular bone loss in the femoral head, a decrease in trabecular bone strength indicators, and compensatory widening of the femoral neck. These results, coupled with diminished regenerative potential of bone marrow stem cells during mechanical unloading in microgravity, have potentially serious implications for bone health and fracture risk during long-duration spaceflight.
Cementless fixation of "isoelastic" hip endoprostheses manufactured from plastic materials.
Morscher, E W; Dick, W
1983-06-01
Nine years of clinical experience with an "isoelastic" shaft prosthesis manufactured using polyacetal resin reveal that for the transmission of forces from the pelvis through the femoral head and neck into the femoral shaft, some rigidity of the proximal part of the prosthesis is necessary. The object is to eliminate micromovements, which lead to bone resorption and implant loosening. However, elasticity greater than that present in metallic implants prevents stress concentrations and disuse stress protection atrophy of the bone. Greater elasticity of the prosthesis, which can be achieved by plastic materials, makes possible a more even, harmonious distribution of the forces transmitted from the implant to the bone and vice versa. A more elastic implant can also act as a better shock absorber than a rigid one. The results in 627 cementless polyethylene cups after a maximum observation period of 5.5 years reveal good incorporation and no aseptic loosening. Especially favorable results occurred in 61 cases by replacing loosened cemented cups with bone grafts and cementless polyethylene cups. On the femoral shaft side too high an elasticity in the proximal part of the prosthesis led to bone resorption and loosening with the first model of the prosthesis. By reinforcing the proximal part of the femoral component, much better results were obtained. The isoelastic femoral shaft, however, is in an early stage of experimentation.
Gebauer, Matthias; Stark, Olaf; Vettorazzi, Eik; Grifka, Joachim; Püschel, Klaus; Amling, Michael; Beckmann, Johannes
2014-01-01
The validity of dual energy X-ray absorptiometry (DXA) and peripheral quantitative computed tomography (pQCT) measurements as predictors of pertrochanteric and femoral neck fracture loads was compared in an experimental simulation of a fall on the greater trochanter. 65 proximal femora were harvested from patients at autopsy. All specimens were scanned with use of DXA for areal bone mineral density and pQCT for volumetric densities at selected sites of the proximal femur. A three-point bending test simulating a side-impact was performed to determine fracture load and resulted in 16 femoral neck and 49 pertrochanteric fractures. Regression analysis revealed that DXA BMD trochanter was the best variable at predicting fracture load of pertrochanteric fractures with an adjusted R(2) of 0.824 (p < 0.0001). There was no correlation between densitometric parameters and the fracture load of femoral neck fractures. A significant correlation further was found between body weight, height, femoral head diameter, and neck length on the one side and fracture load on the other side, irrespective of the fracture type. Clinically, the DXA BMD trochanter should be favored and integrated routinely as well as biometric and geometric parameters, particularly in elderly people with known osteoporosis at risk for falls. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Wang, Chen; Xu, Gui-Jun; Han, Zhe; Jiang, Xuan; Zhang, Cheng-Bao; Dong, Qiang; Ma, Jian-Xiong; Ma, Xin-Long
2015-11-01
The aim of the study was to introduce a new method for measuring the residual displacement of the femoral head after internal fixation and explore the relationship between residual displacement and osteonecrosis with femoral head, and to evaluate the risk factors associated with osteonecrosis of the femoral head in patients with femoral neck fractures treated by closed reduction and percutaneous cannulated screw fixation.One hundred and fifty patients who sustained intracapsular femoral neck fractures between January 2011 and April 2013 were enrolled in the study. All were treated with closed reduction and percutaneous cannulated screw internal fixation. The residual displacement of the femoral head after surgery was measured by 3-dimensional reconstruction that evaluated the quality of the reduction. Other data that might affect prognosis were also obtained from outpatient follow-up, telephone calls, or case reviews. Multivariate logistic regression analysis was applied to assess the intrinsic relationship between the risk factors and the osteonecrosis of the femoral head.Osteonecrosis of the femoral head occurred in 27 patients (18%). Significant differences were observed regarding the residual displacement of the femoral head and the preoperative Garden classification. Moreover, we found more or less residual displacement of femoral head in all patients with high quality of reduction based on x-ray by the new technique. There was a close relationship between residual displacement and ONFH.There exists limitation to evaluate the quality of reduction by x-ray. Three-dimensional reconstruction and digital measurement, as a new method, is a more accurate method to assess the quality of reduction. Residual displacement of the femoral head and the preoperative Garden classification were risk factors for osteonecrosis of the femoral head. High-quality reduction was necessary to avoid complications.
Cheng, Bi-Hua; Chu, Tien-Min G.; Chang, Chawnshang; Kang, Hong-Yo; Huang, Ko-En
2013-01-01
Loss of large bone segments due to fracture resulting from trauma or tumor removal is a common clinical problem. The goal of this study was to evaluate the use of scaffolds containing testosterone, bone morphogenetic protein-2 (BMP-2), or a combination of both for treatment of critical-size segmental bone defects in mice. A 2.5-mm wide osteotomy was created on the left femur of wildtype and androgen receptor knockout (ARKO) mice. Testosterone, BMP-2, or both were delivered locally using a scaffold that bridged the fracture. Results of X-ray imaging showed that in both wildtype and ARKO mice, BMP-2 treatment induced callus formation within 14 days after initiation of the treatment. Testosterone treatment also induced callus formation within 14 days in wildtype but not in ARKO mice. Micro-computed tomography and histological examinations revealed that testosterone treatment caused similar degrees of callus formation as BMP-2 treatment in wildtype mice, but had no such effect in ARKO mice, suggesting that the androgen receptor is required for testosterone to initiate fracture healing. These results demonstrate that testosterone is as effective as BMP-2 in promoting the healing of critical-size segmental defects and that combination therapy with testosterone and BMP-2 is superior to single therapy. Results of this study may provide a foundation to develop a cost effective and efficient therapeutic modality for treatment of bone fractures with segmental defects. PMID:23940550
Femoral artery pseudoaneurysm as a complication of angioplasty. How can it be prevented?
Gupta, Prabha Nini; Salam Basheer, Abdul; Sukumaran, Gireesh Gomaty; Padmajan, Sabin; Praveen, Satheesan; Velappan, Praveen; Nair, Bigesh Unnikrishnan; Nair, Sandeep Govindan; Kunjuraman, Usha Kumari; Madthipat, Unnikrishnan; R, Jayadevan
2013-01-01
Femoral pseudoaneurysm is a common complication of repeated femoral puncture during cardiac catheterisation. We describe here the development of femoral pseudoaneurysms in a patient with Takayasu's arteritis, which healed in response to conservative treatment, and review the literature on the prevention and treatment of femoral pseudoaneurysm. PMID:27326111
Shandling, Adrian; Donohue, Daniel; Tobias, Serge; Wu, Iris; Brar, Ramandeep
2010-01-01
Cardiac resynchronization therapy, which involves the placement of a pacing lead in the right atrium and in each ventricle, is effective in treating heart failure that is caused by left bundle branch block and cardiomyopathy. The left ventricular lead is usually placed into a lateral branch of the coronary sinus via the subclavian route. When the subclavian route is unavailable, insertion of a standard, passive-fixation coronary sinus lead via the femoral approach is feasible; however, the likelihood of subsequent dislodgment is high. Herein, we describe the placement of a novel, self-retaining, active-fixation coronary sinus lead—the Attain StarFix® Model 4195 OTW Lead—in an elderly heart-failure patient, via the femoral approach. We believe that this is the 1st report of this procedure. PMID:20200636
Briffa, Nikolai; Karthickeyan, Raju; Jacob, Joshua; Khaleel, Arshad
2016-11-01
The aim of this study was to compare the biomechanical properties of medial and lateral plating of a medially comminuted supracondylar femoral fracture. A supracondylar femoral fracture model comparing two fixation methods was tested cyclically in axial loading. One-centimetre supracondylar gap osteotomies were created in six synthetic femurs approximately 6 cm proximal to the knee joint. There were two constructs investigated: group 1 and group 2 were stabilized with an 8-hole LC-DCP, medially and laterally, respectively. Both construct groups were axially loaded. Global displacement (total length), wedge displacement, bending moment and strain were measured. Medial plating showed a significantly decreased displacement, bending moment and strain at the fracture site in axial loading. Medial plating of a comminuted supracondylar femur fracture is more stable than lateral plating.
In vivo performance of novel soybean/gelatin-based bioactive and injectable hydroxyapatite foams
Kovtun, Anna; Goeckelmann, Melanie J.; Niclas, Antje A.; Montufar, Edgar B.; Ginebra, Maria-Pau; Planell, Josep A.; Santin, Matteo; Ignatius, Anita
2015-01-01
Major limitations of calcium phosphate cements (CPCs) are their relatively slow degradation rate and the lack of macropores allowing the ingrowth of bone tissue. The development of self-setting cement foams has been proposed as a suitable strategy to overcome these limitations. In previous work we developed a gelatine-based hydroxyapatite foam (G-foam), which exhibited good injectability and cohesion, interconnected porosity and good biocompatibility in vitro. In the present study we evaluated the in vivo performance of the G-foam. Furthermore, we investigated whether enrichment of the foam with soybean extract (SG-foam) increased its bioactivity. G-foam, SG-foam and non-foamed CPC were implanted in a critical-size bone defect in the distal femoral condyle of New Zealand white rabbits. Bone formation and degradation of the materials were investigated after 4, 12 and 20 weeks using histological and biomechanical methods. The foams maintained their macroporosity after injection and setting in vivo. Compared to non-foamed CPC, cellular degradation of the foams was considerably increased and accompanied by new bone formation. The additional functionalization with soybean extract in the SG-foam slightly reduced the degradation rate and positively influenced bone formation in the defect. Furthermore, both foams exhibited excellent biocompatibility, implying that these novel materials may be promising for clinical application in non-loaded bone defects. PMID:25448348
In vivo performance of novel soybean/gelatin-based bioactive and injectable hydroxyapatite foams.
Kovtun, Anna; Goeckelmann, Melanie J; Niclas, Antje A; Montufar, Edgar B; Ginebra, Maria-Pau; Planell, Josep A; Santin, Matteo; Ignatius, Anita
2015-01-01
Major limitations of calcium phosphate cements (CPCs) are their relatively slow degradation rate and the lack of macropores allowing the ingrowth of bone tissue. The development of self-setting cement foams has been proposed as a suitable strategy to overcome these limitations. In previous work we developed a gelatine-based hydroxyapatite foam (G-foam), which exhibited good injectability and cohesion, interconnected porosity and good biocompatibility in vitro. In the present study we evaluated the in vivo performance of the G-foam. Furthermore, we investigated whether enrichment of the foam with soybean extract (SG-foam) increased its bioactivity. G-foam, SG-foam and non-foamed CPC were implanted in a critical-size bone defect in the distal femoral condyle of New Zealand white rabbits. Bone formation and degradation of the materials were investigated after 4, 12 and 20weeks using histological and biomechanical methods. The foams maintained their macroporosity after injection and setting in vivo. Compared to non-foamed CPC, cellular degradation of the foams was considerably increased and accompanied by new bone formation. The additional functionalization with soybean extract in the SG-foam slightly reduced the degradation rate and positively influenced bone formation in the defect. Furthermore, both foams exhibited excellent biocompatibility, implying that these novel materials may be promising for clinical application in non-loaded bone defects. Copyright © 2014 Acta Materialia Inc. All rights reserved.
Cunniffe, Gráinne M; Vinardell, Tatiana; Murphy, J Mary; Thompson, Emmet M; Matsiko, Amos; O'Brien, Fergal J; Kelly, Daniel J
2015-09-01
Clinical translation of tissue engineered therapeutics is hampered by the significant logistical and regulatory challenges associated with such products, prompting increased interest in the use of decellularized extracellular matrix (ECM) to enhance endogenous regeneration. Most bones develop and heal by endochondral ossification, the replacement of a hypertrophic cartilaginous intermediary with bone. The hypothesis of this study is that a porous scaffold derived from decellularized tissue engineered hypertrophic cartilage will retain the necessary signals to instruct host cells to accelerate endogenous bone regeneration. Cartilage tissue (CT) and hypertrophic cartilage tissue (HT) were engineered using human bone marrow derived mesenchymal stem cells, decellularized and the remaining ECM was freeze-dried to generate porous scaffolds. When implanted subcutaneously in nude mice, only the decellularized HT-derived scaffolds were found to induce vascularization and de novo mineral accumulation. Furthermore, when implanted into critically-sized femoral defects, full bridging was observed in half of the defects treated with HT scaffolds, while no evidence of such bridging was found in empty controls. Host cells which had migrated throughout the scaffold were capable of producing new bone tissue, in contrast to fibrous tissue formation within empty controls. These results demonstrate the capacity of decellularized engineered tissues as 'off-the-shelf' implants to promote tissue regeneration. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Rehabilitation after cell transplantation for cartilage defects.
Deszczynski, J; Slynarski, K
2006-01-01
Rehabilitation is a key element of successful treatment of cartilage defects with cell transplantation. The process of graft maturation takes approximately 18 months and cannot be accelerated, but requires carefully introduced steps leading to early recovery of joint function. Rehabilitation starts at 8 hours after surgery with the continuous passive motion (CPM) exercises and physiotherapy. For the first 6 weeks, patients continue with CPM in the range of 0 degrees to 45 degrees for femoral and tibial defects and 0 degrees to 30 degrees for patellofemoral joint reconstruction. Isometric muscle training and scar manual therapy are introduced. Patients are allowed to weight-bear as tolerated from the second week after surgery. After this initial phase, from 6 to 8 weeks after surgery, rehabilitation is accelerated with increased load-bearing and progressive range of motion to full flexion. Usually patients are able to walk without crutches in this time. Proprioceptive training is introduced with the advance of pain-free full range of motion and no discomfort with full weight-bearing. At 6 months after surgery, most patients recover joint function, making it possible for them to return to daily living activities. However, they need to continue with muscle, proprioceptive, and sports-specific rehabilitation exercises. The rehabilitation process is complicated, requiring close cooperation between the patient and surgeon-physiotherapist team to understand the symptoms and address them in a timely fashion.
Davies, J P; Tse, M K; Harris, W H
1996-08-01
Debonding of the cement-metal interface of cemented femoral components of total hip arthroplasty has been shown from clinical and autopsy material to be a common occurrence. Experimentally, debonding has been shown to increase markedly the strains in the adjacent cement mantle. Studies of autopsy-retrieved specimens demonstrate that debonding of the cement-metal interface is a key initiating event in loosening of cemented femoral components of total hip arthroplasty. However, both the radiographic and autopsy evidence of cement-metal interfacial debonding exist after the fact, that is, after debonding has occurred. The lack of prospective data showing that debonding does indeed occur under physiologic loading and occurs prior to other forms of failure of fixation leaves uncertain the issue of debonding and its role in initiating loosening of cemented femoral components. Knowing when, where, and to what extent the cement-metal interface debonds is critical information in understanding the process of loosening of cemented femoral components. Such information would contribute to improving the durability of stems and improving cementing techniques. In this study, the two nondestructive techniques of acoustic emission and ultrasonic evaluation of the cement-metal interface of cemented femoral stems of total hip arthroplasty were combined to investigate when, where, and to what extent cement-metal debonding occurred in vitro in simulated femurs loaded physiologically in fatigue in simulated single-leg stance. Debonding of the cement-metal interface of a cemented femoral component in this model was both an initiating event and a major mechanism of compromise of the cement-metal interface. Additional acoustic emission signals arose from cracks that developed in the cement.
Ramme, Austin J; Egol, Jonathan; Chang, Gregory; Davidovitch, Roy I; Konda, Sanjit
2017-07-01
Difficulty determining anatomic rotation following intramedullary (IM) nailing of the femur continues to be problematic for surgeons. Clinical exam and fluoroscopic imaging of the hip and knee have been used to estimate femoral version, but are inaccurate. We hypothesize that 3D c-arm imaging can be used to accurately measure femoral version following IM nailing of femur fractures to prevent rotational malreduction. A midshaft osteotomy was created in a femur Sawbone to simulate a transverse diaphyseal fracture. An intramedullary (IM) nail was inserted into the Sawbone femur without locking screws or cephalomedullary fixation. A goniometer was used to simulate four femoral version situations after IM nailing: 20° retroversion, 0° version, 15° anteversion, and 30° anteversion. In each simulated position, 3D c-arm imaging and, for comparison purposes, perfect lateral radiographs of the knee and hip were performed. The femoral version of each simulated 3D and fluoroscopic case was measured and the results were tabulated. The measured version from the 3D c-arm images was 22.25° retroversion, 0.66° anteversion, 19.53° anteversion, and 25.15° anteversion for the simulated cases of 20° retroversion, 0° version, 15° anteversion, and 30° anteversion, respectively. The lateral fluoroscopic views were measured to be 9.66° retroversion, 12.12° anteversion, 20.91° anteversion, and 18.77° anteversion for the simulated cases, respectively. This study demonstrates the utility of a novel intraoperative method to evaluate femur rotational malreduction following IM nailing. The use of 3D c-arm imaging to measure femoral version offers accuracy and reproducibility. Copyright © 2017 Elsevier Ltd. All rights reserved.
Gocha, Timothy P; Agnew, Amanda M
2016-05-01
Intracortical remodeling, and the osteons it produces, is one aspect of the bone microstructure that is influenced by and, in turn, can influence its mechanical properties. Previous research examining the spatial distribution of intracortical remodeling density across the femoral midshaft has been limited to either considering only small regions of the cortex or, when looking at the entirety of the cortex, considering only a single individual. This study examined the spatial distribution of all remodeling events (intact osteons, fragmentary osteons, and resorptive bays) across the entirety of the femoral midshaft in a sample of 30 modern cadaveric donors. The sample consisted of 15 males and 15 females, aged 21-97 years at time of death. Using geographic information systems software, the femoral cortex was subdivided radially into thirds and circumferentially into octants, and the spatial location of all remodeling events was marked. Density maps and calculation of osteon population density in cortical regions of interest revealed that remodeling density is typically highest in the periosteal third of the bone, particularly in the lateral and anterolateral regions of the cortex. Due to modeling drift, this area of the midshaft femur has some of the youngest primary tissue, which consequently reveals that the lateral and anterolateral regions of the femoral midshaft have higher remodeling rates than elsewhere in the cortex. This is likely the result of tension/shear forces and/or greater strain magnitudes acting upon the anterolateral femur, which results in a greater amount of microdamage in need of repair than is seen in the medial and posterior regions of the femoral midshaft, which are more subject to compressive forces and/or lesser strain magnitudes. © 2015 Anatomical Society.
Choi, Chong Hyuk; Kim, Sung-Jae; Chun, Yong-Min; Kim, Sung-Hwan; Lee, Su-Keon; Eom, Nam-Kyu; Jung, Min
2018-01-01
The purpose of this study was to find appropriate flexion angle and transverse drill angle for optimal femoral tunnels of anteromedial (AM) bundle and posterolateral (PL) bundle in double-bundle ACL reconstruction using transportal technique. Thirty three-dimensional knee models were reconstructed. Knee flexion angles were altered from 100° to 130° at intervals of 10°. Maximum transverse drill angle (MTA), MTA minus 10° and 20° were set up. Twelve different tunnels were determined by four flexion angles and three transverse drill angles for each bundle. Tunnel length, wall breakage, inter-tunnel communication and graft-bending angle were assessed. Mean tunnel length of AM bundle was >30mm at 120° and 130° of flexion in all transverse drill angles. Mean tunnel length of PL bundle was >30mm during every condition. There were ≥1 cases of wall breakage except at 120° and 130° of flexion with MTA for AM bundle. There was no case of wall breakage for PL bundle. Considering inter-tunnel gap of >2mm without communication and obtuse graft-bending angle, 120° of flexion and MTA could be recommended as optimal condition for femoral tunnels of AM and PL bundles. Flexion angle and transverse drill angle had combined effect on femoral tunnel in double-bundle ACL reconstruction using transportal technique. Achieving flexion angle of 120° and transverse drill angle close to the medial femoral condyle could be recommended as optimal condition for femoral tunnels of AM and PL bundles to avoid insufficient tunnel length, wall breakage, inter-tunnel communication and acute graft-bending angle. Copyright © 2017 Elsevier B.V. All rights reserved.
García Guerrero, Juan J; Fernández de la Concha Castañeda, Joaquín; Doblado Calatrava, Manuel; Redondo Méndez, Ángel; Lázaro Medrano, Manuel; Merchán Herrera, Antonio
2017-06-01
When permanent pacemaker implantation is not possible or advisable via superior venous access (i.e., axillary or subclavian veins), safe and feasible surgical alternatives are required. The femoral approach is relatively unknown and seldom studied. This single-center study analyzed 10-year outcomes of a femoral implantation approach. Data about the implantation procedure (indication, approach, lead and pacemaker models, complications), patient characteristics (age, sex, medications, comorbidities), and follow-up were analyzed for all permanent pacemaker implantations using the femoral approach between June 2001 and June 2011. A permanent pacemaker was implanted with the femoral approach in 50 patients (mean age, 76 years [range: 45-96], 31 [61%] men). The most frequent indication was atrioventricular block, associated with sinus rhythm in 30 patients and with atrial fibrillation in eight patients. Overall, 20 patients (40%) were treated with oral anticoagulants postimplantation. Mean implantation time was 64 minutes (range: 20-210) and mean fluoroscopy time was 6.7 minutes (range: 0.2-50). Minimum follow-up window was 1 year (June 2012), with a mean of 50 months [range: 1-113]). No deaths, septic episodes, or severe complications were associated with the procedure, acute or long-term. Follow-up data were available for 46 patients, of who 21 (46%) died during follow-up (mean age, 87 years [range: 73-101]). No cause of death was associated with the femoral technique. Permanent pacemaker implantation through femoral access is not difficult for an experienced implant surgeon. Outcomes were comparable to systems implanted by superior venous approach, and no severe complications were observed at 10-year follow-up. © 2017 Wiley Periodicals, Inc.
Zhang, X-L; Wang, Y-M; Chu, K; Wang, Z-H; Liu, Y-H; Jiang, L-H; Chen, X; Zhou, Z-Y; Yin, G
2018-02-01
In view of the high occurrence of avascular necrosis of the femoral head (ANFH) after femoral neck fracture and the difficulties in the treatment, our work aimed to explore the effects of platelet-rich plasma (PRP) combined with tri-calcium phosphate (TCP) on the repair of ANFH after femoral neck fracture and to provide reference for clinical treatment. Thirty New Zealand white rabbits were randomly divided into control group, TCP group, and PRP+TCP group. The rabbit ANFH model was established and femoral head tissues were collected. HE staining was used for histological observation. Image analysis and statistical analysis were used to calculate the New Bone Area fraction (NBA %). The levels of bone morphogenetic protein (BMP)-7, transforming growth factor (TGF)-β1, basic fibroblast growth factor (bFGF), interleukin (IL)-6 and tumor necrosis factor (TNF)-a in serum were detected by Enzyme-Linked ImmunoSorbent Assay (ELISA). The new bone area of TCP group was significantly lower than that of PRP+TCP group (p<0.05). Compared with the control group, the levels of BMP-7, TGF-β1 and bFGF were significantly increased in both TCP and PRP+TCP groups (p<0.05), and the increase in PRP+TCP group was higher than that in TCP group. TCP and PRP+TCP can both significantly reduce the content of IL-6 and TNF-a (p<0.05); however, higher decrease was found in PRP+TCP group compared with the TCP group at 8 weeks after injection. PRP combined with TCP, which can promote new bone formation and inhibit inflammatory response, showed higher efficiency in repairing ANFH than internal fixation alone.
Characterization of an Ex vivo Femoral Head Model Assessed by Markers of Bone and Cartilage Turnover
Madsen, Suzi Hoegh; Goettrup, Anne Sofie; Thomsen, Gedske; Christensen, Søren Tvorup; Schultz, Nikolaj; Henriksen, Kim; Bay-Jensen, Anne-Christine; Karsdal, Morten Asser
2011-01-01
Objective: The pathophysiology of osteoarthritis involves the whole joint and is characterized by cartilage degradation and altered subchondral bone turnover. At present, there is a need for biological models that allow investigation of the interactions between the key cellular players in bone/cartilage: osteoblasts, osteoclasts, and chondrocytes. Methods: Femoral heads from 3-, 6-, 9-, and 12-week-old female mice were isolated and cultured for 10 days in serum-free media in the absence or presence of IGF-I (100 nM) (anabolic stimulation) or OSM (10 ng/mL) + TNF-α (20 ng/mL) (catabolic stimulation). Histology on femoral heads before and after culture was performed, and the growth plate size was examined to evaluate the effects on cell metabolism. The conditioned medium was examined for biochemical markers of bone and cartilage degradation/formation. Results: Each age group represented a unique system regarding the interest of bone or cartilage metabolism. Stimulation over 10 days with OSM + TNF-α resulted in depletion of proteoglycans from the cartilage surface in all ages. Furthermore, OSM + TNF-α decreased growth plate size, whereas IGF-I increased the size. Measurements from the conditioned media showed that OSM + TNF-α increased the number of osteoclasts by approximately 80% and induced bone and cartilage degradation by approximately 1200% and approximately 2600%, respectively. Stimulation with IGF-I decreased the osteoclast number and increased cartilage formation by approximately 30%. Conclusion: Biochemical markers and histology together showed that the catabolic stimulation induced degradation and the anabolic stimulation induced formation in the femoral heads. We propose that we have established an explant whole-tissue model for investigating cell-cell interactions, reflecting parts of the processes in the pathogenesis of joint degenerative diseases. PMID:26069585
[Navigated drilling for femoral head necrosis. Experimental and clinical results].
Beckmann, J; Tingart, M; Perlick, L; Lüring, C; Grifka, J; Anders, S
2007-05-01
In the early stages of osteonecrosis of the femoral head, core decompression by exact drilling into the ischemic areas can reduce pain and achieve reperfusion. Using computer aided surgery, the precision of the drilling can be improved while simultaneously lowering radiation exposure time for both staff and patients. We describe the experimental and clinical results of drilling under the guidance of the fluoroscopically-based VectorVision navigation system (BrainLAB, Munich, Germany). A total of 70 sawbones were prepared mimicking an osteonecrosis of the femoral head. In two experimental models, bone only and obesity, as well as in a clinical setting involving ten patients with osteonecrosis of the femoral head, the precision and the duration of radiation exposure were compared between the VectorVision system and conventional drilling. No target was missed. For both models, there was a statistically significant difference in terms of the precision, the number of drilling corrections as well as the radiation exposure time. The average distance to the desired midpoint of the lesion of both models was 0.48 mm for navigated drilling and 1.06 mm for conventional drilling, the average drilling corrections were 0.175 and 2.1, and the radiation exposure time less than 1 s and 3.6 s, respectively. In the clinical setting, the reduction of radiation exposure (below 1 s for navigation compared to 56 s for the conventional technique) as well as of drilling corrections (0.2 compared to 3.4) was also significant. Computer guided drilling using the fluoroscopically based VectorVision navigation system shows a clearly improved precision with a enormous simultaneous reduction in radiation exposure. It is therefore recommended for clinical routine.
Sekiya, Ichiro; Muneta, Takeshi; Horie, Masafumi; Koga, Hideyuki
2015-07-01
Transplantation of mesenchymal stem cells (MSCs) is one possible strategy to achieve articular cartilage repair. We previously reported that synovial MSCs were highly proliferative and able to undergo chondrogenesis. We also found that placing a suspension of synovial MSCs on a cartilage defect for 10 minutes promoted cartilage repair in rabbit and pig models. However, the in vivo efficacy of this approach has not been tested clinically. We asked whether transplantation of synovial MSCs improves (1) MRI features, (2) histologic features, and (3) clinical evaluation scores in patients with cartilage defects in the knee? Patients with a symptomatic single cartilage lesion of the femoral condyle were indicated for inclusion in our study, and between April 2008 and April 2011, 10 patients were enrolled in this study. All patients completed followups of 3 years or more. The average followup period was 52 months (range, 37-80 months). Synovial MSCs were expanded with 10% autologous human serum for 14 days after digestion. For transplantation, the patient was positioned so that the cartilage defect was facing upward, and synovial MSC suspension was placed on the cartilage defect with a syringe under arthroscopic control. The defect with the applied suspension then was held in the upward position for 10 minutes. Five patients underwent concomitant ACL reconstructions, among whom two had meniscus suturing performed simultaneously. For MRI quantification, the cartilage defect was scored from 0 to 5. Second-look arthroscopy was performed for four patients and biopsy specimens were evaluated histologically. Clinical outcome was assessed using the Lysholm score and Tegner Activity Level Scale at final followup. Comparisons of MRI and Lysholm scores before and after treatment for each patient were analyzed using the Wilcoxon signed-rank test. MRI score (median ± 95% CI) was 1.0 ± 0.3 before and 5.0 ± 0.7 after, and increased after treatment in each patient (p = 0.005). Second-look arthroscopy in four patients showed that the cartilage defect appeared to be qualitatively better in all cases. Histologic analyses showed hyaline cartilage in three patients and fibrous cartilage in one at the deep zone. The Lysholm score (median ± 95% CI) was 76 ± 7 before and 95 ± 3 after, and increased after treatment in each patient (p = 0.005). The Tegner Activity Level Scale did not decrease after treatment in each patient. For this small initial case series, transplantation of synovial MSCs was effective in terms of MRI score, qualitative histology, and Lysholm score. The use of synovial MSCs has an advantage in that the cells can be prepared at passage 0 in only 14 days. Transplantation of synovial MSCs may be less invasive than mosaicplasty and autologous chondrocyte implantation. To conclusively show the effectiveness of this treatment requires comparative studies, especially with more established arthroscopic procedures, such as marrow stimulation techniques. Level IV, therapeutic study.
In vivo and in vitro characteristic of HIF-1α and relative genes in ischemic femoral head necrosis
Zhang, Wanglin; Yuan, Zhe; Pei, Xinhong; Ma, Ruixue
2015-01-01
Background: Legg-Calvé-Perthes Disease (Perthes’ disease) is a childhood hip disorder initiated by ischemic necrosis of the growing femoral head. So far, the etiology and pathogenesis of Perthes’ disease is poorly understood. Materials and methods: Avascular osteonecrosis rat model was established to mimic the pathophysiological changes of femoral head necrosis. The chondrocytes of newborn Sprague-Dawley rats were isolated and cultured in hypoxic and normoxic condition. The expression characteristic of the hypoxia-inducible factor-1 alpha (HIF-1α) was evaluated both in vivo and in vitro models. Vascular endothelial growth factor (VEGF) and apoptotic genes in chondrocytes treated with normoxia and hypoxia were also studied. Results: HIF-1α expression increased greatly after ischemic operation and kept at relative high level in the arthromeningitis stage and declined in the stages of osteonecrosis and reconstruction. The HIF-1α mRNA levels of chondrocytes incubated at hypoxia were significantly higher than the cells treated with normoxia at 24 and 72 hours. Hypoxia inhibited VEGF expression; chondrocytes could oppose this inhibition manifested by the increasing of VEGF mRNA level after 72 hours hypoxia. The expression of apoptotic genes, Casp3, Casp8 and Casp9, elevated in chondrocytes after hypoxia with time differences. Conclusion: Hypoxia might be an etiological factor for femoral head necrosis, HIF-1α, VEGF as well as apoptotic genes participated the pathophysiological process of ischemic osteonecrosis. PMID:26261616
Femoral neck shortening after internal fixation of a femoral neck fracture.
Zielinski, Stephanie M; Keijsers, Noël L; Praet, Stephan F E; Heetveld, Martin J; Bhandari, Mohit; Wilssens, Jean Pierre; Patka, Peter; Van Lieshout, Esther M M
2013-07-01
This study assesses femoral neck shortening and its effect on gait pattern and muscle strength in patients with femoral neck fractures treated with internal fixation. Seventy-six patients from a multicenter randomized controlled trial participated. Patient characteristics and Short Form 12 and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were collected. Femoral neck shortening, gait parameters, and maximum isometric forces of the hip muscles were measured and differences between the fractured and contralateral leg were calculated. Variables of patients with little or no shortening, moderate shortening, and severe shortening were compared using univariate and multivariate analyses. Median femoral neck shortening was 1.1 cm. Subtle changes in gait pattern, reduced gait velocity, and reduced abductor muscle strength were observed. Age, weight, and Pauwels classification were risk factors for femoral neck shortening. Femoral neck shortening decreased gait velocity and seemed to impair gait symmetry and physical functioning. In conclusion, internal fixation of femoral neck fractures results in permanent physical limitations. The relatively young and healthy patients in our study seem capable of compensating. Attention should be paid to femoral neck shortening and proper correction with a heel lift, as inadequate correction may cause physical complaints and influence outcome. Copyright 2013, SLACK Incorporated.
Malairungsakul, Anan
2014-12-01
Patients who undergo knee replacement surgery may need to receive a blood transfusion due to blood loss during the operation. Therefore it was important to improve the design of knee implant operative procedures in an attempt to reduce the rate of blood loss. The present study aimed to compare the blood loss between two types of knee replacement surgery. This is a retrospective study in which 78 patients received cemented knee replacements in Phayao Hospital between October 2010 and March 2012. There were two types of surgical procedure: 1) using an implant position covering the end of the femoral bone without cutting into the central part of the distal femoral, 2) using an implant position covering the end of the femoral bone cutting the central part of the distal femoral. Blood loss, blood transfusion, hemoglobin and hematocrit were recorded preoperatively, immediately postsurgery and 48 hours after surgery. Findings revealed that the knee replacement surgery using the implant position covering the end of the femoral bone without cutting the central part of the distal femoral significantly lowered the rate of blood loss when compared to using the implant position covering the end of the femoral bone with central cutting of the distal femor. The average blood loss during the operation without cutting at the central part of distal femoral was 49.50 ± 11.11 mL; whereas the operation cutting the central part of the distal femoral was 58.50 ± 11.69 mL. As regards blood loss, the knee replacement surgery using the implant position covering the end ofthefemoral bone without cutting the central part of distal femor was better than using the implant position covering the end of the femoral bone cutting at the central part of the distal femor.
Prospective evaluation of femoral head viability following femoral neck fracture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Binkert, B.; Kroop, S.A.; Nepola, I.V.
1984-01-01
The bone scans of 33 patients (pts) with recent subcapital fractures (fx) of the femur were evaluated prospectively to determine their value in predicting femoral head visability. Each of the 33 pts (ll men, 22 women, age range 30-92) had a pre-operative bone scan within 72 hrs of the fx (23 pts within 24 hrs). Anterior and posterior planar views of both hips and pinhole views (50% of pts) were obtained 2 hrs after administration of Tc-99m HDP. The femoral head was classified as perfused if it showed the same activity as the opposite normal side or if it showedmore » only slightly decreased activity. Femoral heads showing absent activity were classified as nonperfused. Overall, 20 of the 33 pts showed a photopenic femoral head on the side of the fx. Only 2 pts showed increased activity at hte site of the fx. Internal fixation of the fx was performed in 23 pts, 12 of whom had one or more follow-up scans. Five of these 12 pts showed absent femoral head activity on their initial scan, but 2 showed later reperfusion. The other 7 pts showed good perfusion initially, with only 1 later showing decreased femoral head activity. The other 10 pts (7 of whom had absent femoral head activity) had immediate resection of the femoral head and insertion of a Cathcart prosthesis. The results suggest that femoral head activity seen on a bone scan in the immediate post-fx period is not always a reliable indicator of femoral head viability. Decreased femoral head activity may reflect, in part, compromised perfusion secondary to post-traumatic edema, with or without anatomic disruption of the blood supply.« less
3D geometrical assessment of femoral curvature: a reverse engineering technique.
Chantarapanich, Nattapon; Sitthiseripratip, Kriskrai; Mahaisavariya, Banchong; Wongcumchang, Marut; Siribodhi, Pongwit
2008-09-01
Investigate the 2D/3D geometry of femoral curvature and femoral length using the advanced technique of computerized tomography combined with reverse engineering techniques. The present study was performed using reverse engineering technique based on CT data of 99 cadaveric femora. The femur was divided into three segments, proximal, mid-shaft, and distal regions by defining 35% and 65% of the femoral total length as a boundary of each region. The intramedullary canal in the mid-shaft region was mainly extracted to determine the set of circular center, which could consequence to approximate the 3D femoral radius of curvature using the 3D least square best fit. The 3D femoral curvature was then projected into A-P and M-L directions to investigate the correlation of 2D/3D femoral curvature as normal radiographic images. It was found that the average 3D Thai femoral curvature was 895.46-mm (SD = 238.06) and the average femoral total length is 421.96-mm (SD = 27.61). In addition, the 2D femoral curvature derived from sagittal radiographic image can be used to determine the 3D femoral curvature with this equation: R3D = RSagittal + 3.67 with r = 0.987. This described technique is a non-destructive method that can effectively assess the internal/ external 3D geometric data of the femur The obtained data is useful to develop a proper design of prosthesis that required inserting into the intramedullary canal. From the present study, it can be concluded that the 2DSagittal femoral curvature derived from standard radiographic image can be represented for the 3D femoral curvature.
The femoral nerve is located in the leg and supplies the muscles that assist help straighten the leg. It supplies sensation ... leg. One risk of damage to the femoral nerve is pelvic fracture. Symptoms of femoral nerve damage ...
Morphometric analysis of the femur in cerebral palsy: 3-dimensional CT study.
Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi
2010-09-01
The cause of hip disorder in cerebral palsy (CP) has been thought to involve muscle imbalance, flexion, and adduction contracture of the hip joint, acetabular dysplasia, and femoral growth abnormalities. The aim of this study was to quantitatively evaluate the 3-dimensional femoral geometry and subluxation/dislocation of the hip in spastic CP using 3D-CT reconstructed images of the pelvis and the femur, focusing on the femoral growth abnormalities in CP. Between June 2006 and September 2009, 186 hips in 93 bilateral spastic CP patients, including spastic diplegia (SD) in 73 patients and spastic quadriplegia (SQ) in 20 patients, who had not received any surgical treatment, were investigated using 3D-CT at our hospital. There were 59 boys and 34 girls with an average age of 5.3 years (range: 2.6 to 6.8 y). As an index for the femoral geometry, the neck-shaft angle, the femoral anteversion, and the femoral offset were 3-dimensionally measured. The center of the acetabulum and the femoral head were determined to calculate the CT migration percentage as the distance between these centers divided by the femoral head diameter. To elucidate the factors related to hip subluxation/dislocation, the relationships between the neck-shaft angle, the femoral anteversion, the femoral offset, and the CT migration percentage were investigated. The mean neck-shaft angle was 150.4+/-9.4 degrees (range: 129.4 to 173.2 degrees). The mean femoral anteversion was 44.4+/-13.6 degrees (range: 5.8 to 84.0 degrees). The mean CT migration percentage was 22.4+/-22.7% (range: 3 to 129%). There was positive correlation between the CT migration percentage and the neck-shaft angle (r=0.49). Hips with large CT migration percentage tended to show coxa valga. There was an inverse correlation between the neck-shaft angle and the femoral offset (r=-0.90), but no correlation between the CT migration percentage and the femoral anteversion (r=0.26), between the femoral offset and the femoral anteversion (r=-0.25), or between the neck-shaft angle and the femoral anteversion (r=0.23). The neck-shaft angle, the femoral anteversion, and the CT migration percentage were significantly larger, and the femoral offset was significantly smaller, in patients with the Gross Motor Functional Classification System (GMFCS) level IV/V (nonwalking children) and SQ type, than in patients with GMFCS level II/III (mostly walking children) and SD type. The 3-dimensional femoral geometry in CP patients can be analyzed quantitatively using 3D-CT regardless of the abnormal spastic posture. Our data indicate that 3-dimensional evaluation is accurate and useful for analysis of the femur and acetabulum in CP, and that the extent of coxa valga and femoral anteversion is more severe in the patients with GMFCS level IV/V and SQ type. Level IV.
Hybrid BCI approach to control an artificial tibio-femoral joint.
Mercado, Luis; Rodriguez-Linan, Angel; Torres-Trevino, Luis M; Quiroz, G
2016-08-01
Brain-Computer Interfaces (BCIs) for disabled people should allow them to use their remaining functionalities as control possibilities. BCIs connect the brain with external devices to perform the volition or intent of movement, regardless if that individual is unable to perform the task due to body impairments. In this work we fuse electromyographic (EMG) with electroencephalographic (EEG) activity in a framework called "Hybrid-BCI" (hBCI) approach to control the movement of a simulated tibio-femoral joint. Two mathematical models of a tibio-femoral joint are used to emulate the kinematic and dynamic behavior of the knee. The interest is to reproduce different velocities of the human gait cycle. The EEG signals are used to classify the user intent, which are the velocity changes, meanwhile the superficial EMG signals are used to estimate the amplitude of such intent. A multi-level controller is used to solve the trajectory tracking problem involved. The lower level consists of an individual controller for each model, it solves the tracking of the desired trajectory even considering different velocities of the human gait cycle. The mid-level uses a combination of a logical operator and a finite state machine for the switching between models. Finally, the highest level consists in a support vector machine to classify the desired activity.
Modeling knee joint endoprosthesis mode of deformation
NASA Astrophysics Data System (ADS)
Skeeba, V. Yu; Ivancivsky, V. V.
2018-03-01
The purpose of the work was to define the efficient design of the endoprosthesis, working in a multiple-cycle loading environment. Methodology and methods: triangulated surfaces of the base contact surfaces of endoprosthesis butt elements have been created using the PowerShape and SolidWorks software functional environment, and the assemblies of the possible combinations of the knee joint prosthetic designs have been prepared. The mode of deformation modeling took place in the multipurpose program complex ANSYS. Results and discussion: as a result of the numerical modeling, the following data were obtained for each of the developed knee joint versions: the distribution fields of absolute (total) and relative deformations; equivalent stress distribution fields; fatigue strength coefficient distribution fields. In the course of the studies, the following efficient design assembly has been established: 1) Ti-Al-V alloy composite femoral component with polymer inserts; 2) ceramic liners of the compound separator; 3) a Ti-Al-V alloy composite tibial component. The fatigue strength coefficient for the femoral component is 4.2; for the femoral component polymer inserts is 1.2; for the ceramic liners of the compound separator is 3.1; for the tibial component is 2.7. This promising endoprosthesis structure is recommended for further design and technological development.
Anderson, Dennis E; Madigan, Michael L
2013-10-01
Maintenance of healthy bone mineral density (BMD) is important for preventing fractures in older adults. Strains experienced by bone in vivo stimulate remodeling processes, which can increase or decrease BMD. However, there has been little study of age differences in bone strains. This study examined the relative contributions of age-related differences in femoral loading and BMD to age-related differences in femoral strains during walking using gait analysis, static optimization, and finite element modeling. Strains in older adult models were similar or larger than in young adult models. Reduced BMD increased strains in a fairly uniform manner, whereas older adult loading increased strains in early stance but decreased strains in late stance. Peak ground reaction forces, hip joint contact forces, and hip flexor forces were lower in older adults in late stance phase, and this helped older adults maintain strains similar to those of young adults despite lower BMD. Because walking likely represents a "baseline" level of stimulus for bone remodeling processes, increased strains during walking in older adults might indicate the extent of age-related impairment in bone remodeling processes. Such a measure might be clinically useful if it could be accurately determined with age-appropriate patient-specific loading, geometry, and BMD.
Stojanović, Marko; Prostran, Milica; Janković, Radmila; Radenković, Miroslav
2017-07-01
Recent findings have demonstrated that serotonin is an important participant in the development and progression of peripheral artery diseases. Taking this into consideration, the goals of this study were to investigate the effects of serotonin on isolated Wistar rat femoral arteries in both healthy and diabetic animals, with and without artery occlusion, with a particular focus on determining the role of calcium in this process. Contraction experiments with serotonin on intact and denuded femoral artery rings, in the presence or absence of nifedipine and ouabain (both separately, or in combination), as well as Ca 2+ -free Krebs-Ringer bicarbonate solution were performed. The serotonin-induced results were concentration dependent, but only in healthy animals. The endothelium-dependent contraction of the femoral artery was assessed. In healthy animals, the endothelium-reliant part of contraction was dependent on the extracellular calcium, while the smooth muscle-related part was instead dependent on the intracellular calcium. In diabetic animals, both nifedipine and ouabain influenced serotonin-induced vascular effects by blocking intracellular calcium pathways. However, this was diminished after the simultaneous administration of both blockers. © 2017 John Wiley & Sons Australia, Ltd.
Lonchena, Tiffany K; McFadden, Kathryn; Orebaugh, Steven L
2016-01-01
Correlation between ultrasound appearance, gross anatomic characteristics, and histologic structure of the femoral nerve (FN) is lacking. Utilizing cadavers, we sought to characterize the anatomy of the FN, and provide a quantitative measure of its branching. We hypothesize that at the femoral crease, the FN exists as a group of nerve branches, rather than a single nerve structure, and secondarily, that this transition into many branches is apparent on ultrasonography. Nineteen preserved cadavers were investigated. Ultrasonography was sufficient to evaluate the femoral nerve in nine specimens; gross dissection was utilized in all 19. Anatomic characteristics were recorded, including distances from the inguinal ligament to femoral crease, first nerve branch, and complete arborization of the nerve. The nerves from nine specimens were excised for histologic analysis. On ultrasound, the nerve became more flattened, widened, and less discrete as it coursed distally. Branching of the nerve was apparent in 12 of 18 images, with mean distance from inguinal ligament of 3.9 (1.0) cm. However, upon dissection, major branching of the femoral nerve occurred at 3.1 (1.0) cm distal to the inguinal ligament, well proximal to the femoral crease. Histologic analysis was consistent with findings at dissection. The femoral nerve arborizes into multiple branches between the inguinal ligament and the femoral crease. Initial branching is often high in the femoral triangle. As hypothesized, the FN exists as a closely associated group of nerve branches at the level of the femoral crease; however, the termination of the nerve into multiple branches is not consistently apparent on ultrasonography.
Hiramatsu, Kunihiko; Mae, Tatsuo; Tachibana, Yuta; Nakagawa, Shigeto; Shino, Konsei
2018-02-01
The purpose of this study was to compare the femoral tunnel length, the femoral graft bending angle at the femoral tunnel aperture, and the contact area between the femoral tunnel wall and an interference screw used for fixation in anatomic rectangular tunnel anterior cruciate ligament (ACL) reconstruction (ART ACLR). The study included 149 patients with primary ACL injury who underwent ART ACLR. Preoperatively, flexion angle of the index knee was checked under general anaesthesia. Those of less than 130° of passive flexion were assigned to the outside-in (OI) technique (78 patients), while the others to the trans-portal inside-out (TP) technique (71 patients). The patients underwent computed tomography with multiplanar reconstruction at 3-5 weeks post-operatively. Femoral tunnel length, graft bending angle, and contact ratio between the IFS and femoral tunnel were assessed. P < 0.05 was considered statistically significant. The femoral tunnel length in the OI technique was significantly longer than that in the TP technique (P < 0.001). The femoral graft bending angle in the OI technique was significantly more acute than that in the TP technique (P < 0.001). The contact ratio in the OI technique was significantly larger than that in the TP technique at every point in the femoral tunnel (P < 0.001). The OI technique resulted in a more acute femoral graft bending angle, longer mean femoral tunnel length, and larger contact ratio than the TP technique after ART ACLR. Retrospective comparative study, Level III.
Bhattacharyya, Rahul; Ker, Andrew; Fogg, Quentin; Spencer, Simon J; Joseph, Jibu
2018-02-01
Incorrect femoral tunnel placement is the most common cause of graft failure during Anterior Cruciate Ligament (ACL) Reconstruction. A reliable landmark can minimize errors. To identify whether the Lateral Intercondylar Ridge (LIR) is a consistent anatomical structure and define its relationship with the femoral ACL insertion. Phase 1: we studied 23 femoral dry bone specimens macroscopically. Using a digital microscribe, the medial surface of the lateral femoral condyle was reconstructed (3D) to evaluate whether there was an identifiable bony ridge. Phase 2: 7 cadaveric specimens with intact soft tissues were dissected to identify the femoral ACL insertion. A 3D reconstruction of the femoral ACL insertion and the surface allowed us to define the relationship between the LIR and the ACL insertion. All specimens had a defined LIR on the medial surface of the lateral femoral condyle. The ridge was consistently located just anterior to the femoral ACL insertion. The ACL footprint was present in the depression between the ridge and the Inferior Articular Cartilage Margin (IACM). The mean distance from the midpoint of the IACM to the LIR was 10.1 mm. This is the first study to use the microscribe to digitally reconstruct the medial surface of the lateral femoral condyle. It shows that the LIR is a consistent anatomical structure that defines the anterior margin of the femoral ACL insertion, which guides femoral tunnel placement. Our findings support the ruler technique, which is a commonly used method for anatomic single bundle ACL reconstruction. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Operative Mortality After Arthroplasty for Femoral Neck Fracture and Hospital Volume.
Maceroli, Michael A; Nikkel, Lucas E; Mahmood, Bilal; Elfar, John C
2015-12-01
The purpose of the present study is to use a statewide, population-based data set to identify mortality rates at 30-day and 1-year postoperatively following total hip arthroplasty (THA) and hemiarthroplasty (HA) for displaced femoral neck fractures. The secondary aim of the study is to determine whether arthroplasty volume confers a protective effect on the mortality rate following femoral neck fracture treatment. New York's Statewide Planning and Research Cooperative System was used to identify 45 749 patients older than 60 years of age with a discharge diagnosis of femoral neck fracture undergoing THA or HA from 2000 through 2010. Comorbidities were identified using the Charlson comorbidity index. Mortality risk was modeled using Cox proportional hazards models while controlling for demographic and comorbid characteristics. High-volume THA centers were defined as those in the top quartile of arthroplasty volume, while low-volume centers were defined as the bottom quartile. Patients undergoing THA for femoral neck fracture rather than HA were younger (79 vs 83 years, P < .001), more likely to have rheumatoid disease, and less likely to have heart disease, dementia, cancer, or diabetes (all P < .05). Thirty-day mortality after HA was higher (8.4% vs 5.7%; P < .001) as was 1-year mortality (25.9% vs 17.8%; P < .001). After controlling for age, gender, ethnicity, and comorbidities, risk of mortality following THA was 21% lower (hazard ratio [HR] 0.79; P = .003) at 30 days and 22% lower (HR 0.78; P < .001) at 1 year than HA. Patients undergoing THA at high-volume arthroplasty centers had improved 1-year mortality when compared to those undergoing THA at low-volume hospitals (HR 0.55; P = .008). Based on this large, population-based study, there is no basis to assume THA carries a greater mortality risk after hip fracture than does standard HA, even when accounting for institutional volume of hip arthroplasty.
Tang, Jing; Thorhauer, Eric; Marsh, Chelsea; Fu, Freddie H.
2013-01-01
Purpose Femoral tunnel angle (FTA) has been proposed as a metric for evaluating whether ACL reconstruction was performed anatomically. In clinic, radiographic images are typically acquired with an uncertain amount of internal/external knee rotation. The extent to which knee rotation will influence FTA measurement is unclear. Furthermore, differences in FTA measurement between the two common positions (0° and 45° knee flexion) have not been established. The purpose of this study was to investigate the influence of knee rotation on FTA measurement after ACL reconstruction. Methods Knee CT data from 16 subjects were segmented to produce 3D bone models. Central axes of tunnels were identified. The 0° and 45° flexion angles were simulated. Knee internal/external rotations were simulated in a range of ±20°. FTA was defined as the angle between the tunnel axis and femoral shaft axis, orthogonally projected into the coronal plane. Results Femoral tunnel angle was positively/negatively correlated with knee rotation angle at 0°/45° knee flexion. At 0° knee flexion, FTA for anterio-medial (AM) tunnels was significantly decreased at 20° of external knee rotation. At 45° knee flexion, more than 16° external or 19° internal rotation significantly altered FTA measurements for single-bundle tunnels; smaller rotations (±9° for AM, ±5° for PL) created significant errors in FTA measurements after double-bundle reconstruction. Conclusion Femoral tunnel angle measurements were correlated with knee rotation. Relatively small imaging malalignment introduced significant errors with knee flexed 45°. This study supports using the 0° flexion position for knee radiographs to reduce errors in FTA measurement due to knee internal/external rotation. Level of evidence Case–control study, Level III. PMID:23589127
Wassel, Christina L; Ellis, Alicia M; Suder, Natalie C; Barinas-Mitchell, Emma; Rifkin, Dena E; Forbang, Nketi I; Denenberg, Julie O; Marasco, Antoinette M; McQuaide, Belinda J; Jenny, Nancy S; Allison, Matthew A; Ix, Joachim H; Criqui, Michael H
2017-07-20
The ankle-brachial index (ABI) is inadequate to detect early-stage atherosclerotic disease, when interventions to prevent functional decline may be the most effective. We determined associations of femoral artery atherosclerosis with physical functioning, across the spectrum of the ABI, and within the normal ABI range. In 2007-2011, 1103 multiethnic men and women participated in the San Diego Population Study, and completed all components of the summary performance score. Using Doppler ultrasound, superficial and common femoral intima media thickness and plaques were ascertained. Logistic regression was used to assess associations of femoral atherosclerosis with the summary performance score and its individual components. Models were adjusted for demographics, lifestyle factors, comorbidities, lipids, and kidney function. In adjusted models, among participants with a normal-range ABI (1.00-1.30), the highest tertile of superficial intima media thickness was associated with lower odds of a perfect summary performance score of 12 (odds ratio=0.56 [0.36, 0.87], P =0.009), and lower odds of a 4-m walk score of 4 (0.34 [0.16, 0.73], P =0.006) and chair rise score of 4 (0.56 [0.34, 0.94], P =0.03). Plaque presence (0.53 [0.29, 0.99], P =0.04) and greater total plaque burden (0.61 [0.43, 0.87], P =0.006) were associated with worse 4-m walk performance in the normal-range ABI group. Higher superficial intima media thickness was associated with lower summary performance score in all individuals ( P =0.02). Findings suggest that use of femoral artery atherosclerosis measures may be effective in individuals with a normal-range ABI, especially, for example, those with diabetes mellitus or a family history of peripheral artery disease, when detection can lead to earlier intervention to prevent functional declines and improve quality of life. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Dargel, Jens; Koebke, Jürgen; Brüggemann, Gert-Peter; Pennig, Dietmar; Schmidt-Wiethoff, Rüdiger
2009-10-01
This study investigates the influence of various femoral anterior cruciate ligament graft fixation methods on the amount of tension degradation and the initial fixation strength after cyclic flexion-extension loading in a porcine knee model. One hundred twenty porcine digital extensor tendons, used as 4-stranded free tendon grafts, were fixated within porcine femoral bone tunnels by use of extracortical button, cross-pin, or interference screw fixation. One hundred twenty porcine patellar tendon-bone grafts were fixated by use of cross-pin, interference screw, or press-fit fixation. Each femur-graft complex was submitted to cyclic flexion-extension loading for 1,000 cycles throughout different loading ranges, and the total loss of tension was determined. After cyclic testing, the grafts were loaded to failure, and the data were compared with a pullout series without cyclic loading. Tension degradation after 1,000 cycles of flexion-extension loading averaged 62.6% +/- 10.0% in free tendon grafts and 48.9% +/- 13.35% in patellar tendon-bone grafts. There was no influence of the loading range on the total amount of tension degradation. The total amount of tension degradation was the highest with interference screw fixation of free tendon and patellar tendon-bone grafts. Despite excessive loss of tension, the initial fixation strength of the femur-graft complex was not reduced. The method of femoral graft fixation significantly influenced tension degradation during dynamic flexion-extension loading. Femoral graft fixation methods that secure the graft close to the tunnel entrance and that displace the graft substance from the center of the bone tunnel show the largest amount of tension degradation during cyclic flexion-extension loading. The graft substance, not the fixation site, was the weakest link of the graft complex within this investigation. We believe that the graft fixation method should be considered when aiming to improve the precision of femoral graft placement in anterior cruciate ligament reconstruction.
Novel Method to Assess Arterial Insufficiency in Rodent Hindlimb
Ziegler, Matthew A.; DiStasi, Matthew R.; Miller, Steven J.; Dalsing, Michael C.; Unthank, Joseph L.
2015-01-01
Background Lack of techniques to assess maximal blood flow capacity thwarts the use of rodent models of arterial insufficiency to evaluate therapies for intermittent claudication. We evaluated femoral vein outflow (VO) in combination with stimulated muscle contraction as a potential method to assess functional hindlimb arterial reserve and therapeutic efficacy in a rodent model of subcritical limb ischemia. Materials and methods VO was measured with perivascular flow probes at rest and during stimulated calf muscle contraction in young healthy rats (Wistar Kyoto, WKY; lean Zucker, LZR) and rats with cardiovascular risk factors (Spontaneously Hypertensive, SHR; Obese Zucker, OZR) with acute and/or chronic femoral arterial occlusion. Therapeutic efficacy was assessed by administration of Ramipril or Losartan to SHR after femoral artery excision. Results VO measurement in WKY demonstrated the utility of this method to assess hindlimb perfusion at rest and during calf muscle contraction. While application to diseased models (OZR, SHR) demonstrated normal resting perfusion compared to contralateral limbs, a significant reduction in reserve capacity was uncovered with muscle stimulation. Administration of Ramipril and Losartan demonstrated significant improvement in functional arterial reserve. Conclusion The results demonstrate that this novel method to assess distal limb perfusion in small rodents with subcritical limb ischemia is sufficient to unmask perfusion deficits not apparent at rest, detect impaired compensation in diseased animal models with risk factors, and assess therapeutic efficacy. The approach provides a significant advance in methods to investigate potential mechanisms and novel therapies for subcritical limb ischemia in pre-clinical rodent models. PMID:26850199
Lecerf, G; Fessy, M H; Philippot, R; Massin, P; Giraud, F; Flecher, X; Girard, J; Mertl, P; Marchetti, E; Stindel, E
2009-05-01
BACKGROUND OBJECTIVE: Femoral offset is supposed to influence the results of hip replacement but little is known about the accurate method of measure and the true effect of offset modifications. This article is a collection of independent anatomic, radiological and clinical works, which purpose is to assess knowledge of the implications of femoral offset for preoperative templating and total hip arthroplasty. There is a strong correlation between femoral offset, abductors lever arm and hip abductor strength. Hip lateralization is independent of the femoral endomedullary characteristics. The abductors lever arm is highly correlated to the gluteus medius activation angle. There were correlations between femoral offset and endomedullary shape. The hip center was high and medial for stovepipe metaphysis while it was lower and lateralized for champagne - flute upper femur. A study was performed to compare the femoral offset measured by X-ray and CT-scan in 50 patients, demonstrated that plain radiography underestimates offset measurement. The 2D templating cannot appreciate the rotation of the lower limb. Taking into account the horizontal plane is essential to obtain proper 3D planning of the femoral offset. A randomized study was designed to compare femoral offset measurements after hip resurfacing and total hip arthroplasty. This study underlined hip resurfacing reduced the femoral offset, while hip replacement increased offset. However, the reduction of femoral offset after hip resurfacing does not affect the function. A pilot study was designed to assess the results of 120 hip arthroplasties with a modular femoral neck. This study showed that the use of a modular collar ensures an easier restoration of the femoral offset. A cohort of high offset stems (Lubinus 117 degrees) was retrospectively assessed. The survival rate was slightly lower that the standard design reported in the Swedish register. Finally, the measurement of offset and leg length was assessed with the help of computer assistance. The software changed the initial schedule (obtained by templating) in 29%. Therefore, femoral offset restoration is essential to improve function and longevity of hip arthroplasty. CT-scan is more accurate than plain radiography to assess femoral offset. Hip resurfacing decreases offset without effect on function. Modular neck and computer assistance may improve intraoperative calculation and reproduction of femoral offset. Increasing offset with a standard cemented design may decrease long-term fixation. Level IV: Retrospective or historical series.
Ma, Xiao-Wei; Cui, Da-Ping; Zhao, De-Wei
2015-01-01
Vascular endothelial cell growth factor (VEGF) combined with bone morphogenetic protein (BMP) was used to repair avascular necrosis of the femoral head, which can maintain the osteogenic phenotype of seed cells, and effectively secrete VEGF and BMP-2, and effectively promote blood vessel regeneration and contribute to formation and revascularization of tissue engineered bone tissues. To observe the therapeutic effect on the treatment of avascular necrosis of the femoral head by using bone marrow mesenchymal stem cells (BMSCs) modified by VEGF-165 and BMP-2 in vitro. The models were avascular necrosis of femoral head of rabbits on right leg. There groups were single core decompression group, core decompression + BMSCs group, core decompression + VEGF-165/BMP-2 transfect BMSCs group. Necrotic bone was cleared out under arthroscope. Arthroscopic observation demonstrated that necrotic bone was cleared out in each group, and fresh blood flowed out. Histomorphology determination showed that blood vessel number and new bone area in the repair region were significantly greater at various time points following transplantation in the core decompression + VEGF-165/BMP-2 transfect BMSCs group compared with single core decompression group and core decompression + BMSCs group (P < 0.05). These suggested that VEGF-165/BMP-2 gene transfection strengthened osteogenic effects of BMSCs, elevated number and quality of new bones and accelerated the repair of osteonecrosis of the femoral head. PMID:26629044
Brown, Philip J; Mannava, Sandeep; Seyler, Thorsten M; Plate, Johannes F; Van Sikes, Charles; Stitzel, Joel D; Lang, Jason E
2016-10-26
Femoral head core decompression is an efficacious joint-preserving procedure for treatment of early stage avascular necrosis. However, postoperative fractures have been described which may be related to the decompression technique used. Femoral head decompressions were performed on 12 matched human cadaveric femora comparing large 8mm single bore versus multiple 3mm small drilling techniques. Ultimate failure strength of the femora was tested using a servo-hydraulic material testing system. Ultimate load to failure was compared between the different decompression techniques using two paired ANCOVA linear regression models. Prior to biomechanical testing and after the intervention, volumetric bone mineral density was determined using quantitative computed tomography to account for variation between cadaveric samples and to assess the amount of bone disruption by the core decompression. Core decompression, using the small diameter bore and multiple drilling technique, withstood significantly greater load prior to failure compared with the single large bore technique after adjustment for bone mineral density (p< 0.05). The 8mm single bore technique removed a significantly larger volume of bone compared to the 3mm multiple drilling technique (p< 0.001). However, total fracture energy was similar between the two core decompression techniques. When considering core decompression for the treatment of early stage avascular necrosis, the multiple small bore technique removed less bone volume, thereby potentially leading to higher load to failure.
Fajardo, Roberto J; Müller, Ralph; Ketcham, Rich A; Colbert, Matthew
2007-04-01
Functional analyses of human and nonhuman anthropoid primate femoral neck structure have largely ignored the trabecular bone. We tested hypotheses regarding differences in the relative distribution and structural anisotropy of trabecular bone in the femoral neck of quadrupedal and climbing/suspensory anthropoids. We used high-resolution X-ray computed tomography to analyze quantitatively the femoral neck trabecular structure of Ateles geoffroyi, Symphalangus syndactylus, Alouatta seniculus, Colobus guereza, Macaca fascicularis, and Papio cynocephalus (n = 46). We analyzed a size-scaled superior and inferior volume of interest (VOI) in the femoral neck. The ratio of the superior to inferior VOI bone volume fraction indicated that the distribution of trabecular bone was inferiorly skewed in most (but not all) quadrupeds and evenly distributed the climbing/suspensory species, but interspecific comparisons indicated that all taxa overlapped in these measurements. Degree of anisotropy values were generally higher in the inferior VOI of all species and the results for the two climbing/suspensory taxa, A. geoffroyi (1.71 +/- 0.30) and S. syndactylus (1.55 +/- 0.04), were similar to the results for the quadrupedal anthropoids, C. guereza (male = 1.64 +/- 0.13; female = 1.68 +/- 0.07) and P. cynocephalus (1.47 +/- 0.13). These results suggest strong trabecular architecture similarity across body sizes, anthropoid phylogenetic backgrounds, and locomotor mode. This structural similarity might be explained by greater similarity in anthropoid hip joint loading mechanics than previously considered. It is likely that our current models of anthropoid hip joint mechanics are overly simplistic.
Han, Yung; Sardar, Zeeshan; McGrail, Scott; Steffen, Thomas; Martineau, Paul A
2011-12-01
Sixteen case reports of distal femur fractures as post-operative complications after anterior cruciate ligament (ACL) reconstruction have been described in the literature. The femoral tunnel has been suggested as a potential stress riser for fracture formation. Additionally, double bundle ACL reconstructions may compound this risk. This is the first biomechanical study to examine the significance of a stress riser effect of the femoral tunnel(s) after ACL reconstruction. The hypotheses tested in this study are that the femoral tunnel acts as a stress riser for fracture and that this effect increases with the size of the tunnel (8 mm vs. 10 mm) and with the number of tunnels (1 vs. 2). Femoral tunnels simulating single bundle (SB) hamstring graft (8 mm), bone-patellar tendon-bone graft (10 mm), and double bundle (DB) ACL reconstruction (7, 6 mm) were drilled in fourth-generation saw bones. These three experimental groups and a control group consisting of native saw bones without tunnels were loaded to failure. All fractures occurred through the tunnels in the DB group, whereas fractures did not consistently occur through the tunnels in the SB groups. The mean fracture load was 6,145N ± 471N in the native group, 5,691N ± 198N in the 8 mm SB group, 5,702N ± 282N in the 10 mm SB group, and 4,744N ± 418N in the DB group. The mean fracture load for the DB group was significantly lower when compared to the native, 8 mm SB, and 10 mm SB groups independently (P value = 0.0016, 0.0060, and 0.0038, respectively). The mean fracture loads for neither SB groups were not significantly different from the native group. An anatomically placed femoral tunnel in single bundle ACL reconstruction in our experimental model was not a significant stress riser to fracture, whereas the two femoral tunnels in double bundle ACL reconstruction significantly decreased load to failure. The results support the sparsity of reported peri-ACL reconstruction femur fractures in single femoral tunnel techniques. However, the increased fracture risk in double bundle ACL reconstruction may be a cause for concern and impact patient selection.
Mechanical consequences of core drilling and bone-grafting on osteonecrosis of the femoral head.
Brown, T D; Pedersen, D R; Baker, K J; Brand, R A
1993-09-01
We employed an anatomically realistic three-dimensional finite-element model to explore several biomechanical variables involved in coring or bone-grafting of a segmentally necrotic femoral head. The mechanical efficacy of several variants of these procedures was indexed in terms of their alteration of the stress:strength ratio in at-risk necrotic cancellous bone. For coring alone, the associated structural compromise was generally modest, provided that the tract did not extend near the subchondral plate. Cortical bone-grafting was potentially of great structural benefit for femoral heads in which the graft penetrated deeply into the superocentral or lateral aspect of the lesion, ideally with abutment against the subchondral plate. By contrast, central or lateral grafts that stopped well short of the subchondral plate were contraindicated biomechanically because they caused marked elevations in stress on the necrotic cancellous bone. Calculated levels of stress were relatively insensitive to variations in the diameter of the graft.
Kroeber, Markus W; Rovinsky, David; Haskell, Andrew; Heilmann, Moira; Llotz, Jeff; Otsuka, Norman
2002-06-01
This study compared cannulated 4.5-mm bioabsorbable screws made of self-reinforced poly-levolactic acid to cannulated 4.5-mm steel and titanium screws for resistance to shear stress and ability to generate compression in a polyurethane foam model of slipped capital femoral epiphysis fixation. The maximum shear stress resisted by the three screw types was similar (self-reinforced poly-levolactic acid 371 +/- 146 MPa, steel 442 +/- 43 MPa, and titanium 470 +/- 91 MPa). The maximum compression generated by both the self-reinforced poly-levolactic acid screw (68.5 +/- 3.3 N) and the steel screw (63.3 +/- 5.9 N) was greater than that for the titanium screw (3 +/- 1.4 N, P <.05). These data suggest cannulated self-reinforced poly-levolactic acid screws can be used in the treatment of slipped capital femoral epiphysis because of their sufficient biomechanical strength.
Manzini, Francesco; Manzini, Claudio; Cesana, Giancarlo; Riva, Michele Augusto
2017-02-01
During the Middle Ages and the Renaissance, intellectuals often included clinical cases and medical descriptions in their literary works. These authors appeared to be more interested in internal and infectious diseases rather than in musculoskeletal disorders and orthopaedics. François Rabelais (1490-1553) was one of the most renowned humanists and philologists of the sixteenth century. He was also a physician with an interest in translating ancient texts of medical authors. Rabelais rediscovered a device for treating femoral fracture originally described by the Roman physician Galen and named as glossocomion. Since the original apparatus had some imperfections, Rabelais redesigned and modified it. This new, improved version became a model for new devices for treating femoral fracture, as also reported by the great French surgeon Ambroise Paré. For this contribution, Rabelais deserves major consideration in the history of orthopaedics and traumatology.
Inzana, Jason A.; Schwarz, Edward M.; Kates, Stephen L.; Awad, Hani A.
2014-01-01
Mice are the small animal model of choice in biomedical research due to the low cost and availability of genetically engineered lines. However, the devices utilized in current mouse models of implant-associated bone infection have been limited to intramedullary or trans-cortical pins, which are not amenable to treatments involving extensive debridement of a full-thickness bone loss and placement of a segmental antibiotic spacer. To overcome these limitations, we developed a clinically faithful model that utilizes a locking fracture fixation plate to enable debridement of an infected segmental bone defect (full-thickness osteotomy) during a revision surgery, and investigated the therapeutic effects of placing an antibiotic-laden spacer in the segmental bone defect. To first determine the ideal time point for revision following infection, a 0.7 mm osteotomy in the femoral mid-shaft was stabilized with a radiolucent PEEK fixation plate. The defect was inoculated with bioluminescent Staphylococcus aureus, and the infection was monitored over 14 days by bioluminescent imaging (BLI). Osteolysis and reactive bone formation were assessed by X-ray and micro-computed tomography (micro-CT). The active bacterial infection peaked by 5 days post-inoculation, however the stability of the implant fixation became compromised by 10–14 days post-inoculation due to osteolysis around the screws. Thus, day 7 was defined as the ideal time point to perform the revision surgery. During the revision surgery, the infected tissue was debrided and the osteotomy was widened to 3 mm to place a poly-methyl methacrylate spacer, with or without vancomycin. Half of the groups also received systemic vancomycin for the remaining 21 days of the study. The viable bacteria remaining at the end of the study were measured using colony forming unit assays. Volumetric bone changes (osteolysis and reactive bone formation) were directly measured using micro-CT image analysis. Mice that were treated with local or systemic vancomycin did not display gross pathology at the end of the study. While localized vancomycin delivery alone tended to decrease the bacterial burden and osteolysis, these effects were only significant when combined with systemic antibiotic therapy. This novel mouse model replicates key features of implant-associated osteomyelitis that make treatment extremely difficult, such as biofilm formation and osteolysis, and imitates the clinical practice of placing an antibiotic-laden spacer after infected tissue debridement. In addition, the model demonstrates the limitations of current PMMA spacers and could be an invaluable tool for evaluating alternative antimicrobial treatments for implant-associated bone infection. PMID:25459073
Tang, Fan; Zhou, Yong; Zhang, Wenli; Min, Li; Shi, Rui; Luo, Yi; Duan, Hong; Tu, Chongqi
2017-04-04
Whether all-polyethylene tibial (APT) components are beneficial to patients who received distal femur limb-salvage surgery lacks high-quality clinical follow-up and mechanical evidence. This study aimed to investigate the biomechanics of the distal femur reconstructed with APT tumor knee prostheses using finite element (FE) analysis based on our previous, promising clinical outcome. Three-dimensional FE models that use APT and metal-backed tibial (MBT) prostheses to reconstruct distal femoral bone defects were developed and input into the Abaqus FEA software version 6.10.1. Mesh refinement tests and gait simulation with a single foot both in the upright and 15°-flexion positions with mechanical loading were conducted. Stress distribution analysis was compared between APT and MBT at the two static positions. For both prosthesis types, the stress was concentrated on the junction of the stem and shaft, and the maximum stress in the femoral axis base was more than 100 Mpa. The stress on the tibial surface was relatively distributed, which was 1-19 MPa. The stress on the tibial bone-cement layer of the APT prosthesis was approximately 20 times higher than that on the MBT prosthesis in the same region. The stress on the proximal tibial cancellous bone and cortical bone of the APT prosthesis was 3-5 times greater than that of the MBT prosthesis, and it was more distributed. Although the stress of bone-cement around the APT component is relatively high, the stress was better distributed at the polyethylene-cement-bone interface in APT than in MBT prosthesis, which effectively protects the proximal tibia in distal femur tumor knee prosthesis replacement. These results should be considered when selecting the appropriate tibial component for a patient, especially under the foreseeable conditions of osteoporosis.
Actis Total Hip System 2 Year Follow-up
2017-08-14
Osteoarthritis; Traumatic Arthritis; Rheumatoid Arthritis; Congenital Hip Dysplasia; Avascular Necrosis of the Femoral Head; Acute Traumatic Fracture of the Femoral Head or Neck; Certain Cases of Ankylosis; Non-union of Femoral Neck Fractures; Certain High Sub-Capital & Femoral Neck Fractures in Elderly
Patient-specific finite element modeling for femoral bone augmentation
Basafa, Ehsan; Armiger, Robert S.; Kutzer, Michael D.; Belkoff, Stephen M.; Mears, Simon C.; Armand, Mehran
2015-01-01
The aim of this study was to provide a fast and accurate finite element (FE) modeling scheme for predicting bone stiffness and strength suitable for use within the framework of a computer-assisted osteoporotic femoral bone augmentation surgery system. The key parts of the system, i.e. preoperative planning and intraoperative assessment of the augmentation, demand the finite element model to be solved and analyzed rapidly. Available CT scans and mechanical testing results from nine pairs of osteoporotic femur bones, with one specimen from each pair augmented by polymethylmethacrylate (PMMA) bone cement, were used to create FE models and compare the results with experiments. Correlation values of R2 = 0.72–0.95 were observed between the experiments and FEA results which, combined with the fast model convergence (~3 min for ~250,000 degrees of freedom), makes the presented modeling approach a promising candidate for the intended application of preoperative planning and intraoperative assessment of bone augmentation surgery. PMID:23375663
Vora, Padmanabh H; Musa, Rameez; Bhavsar, Neel M; Shah, Darshan
2017-01-01
Introduction: Giant Cell Tumor(GCT) is one of an infrequently encountered tumor by orthopaedic surgeons in clinical practice. It is described as ‘locally malignant’ tumor found in epimetaphyseal region of long bones, peculiarly around knee. We present a case of a solitary, benign Campanacci Grade 2 GCT in right lateral femoral condyle in 38 year old female and our treatment. Case Report: A 38 year old female presented to our outpatient department with chief complaint of constant, moderate pain in right knee increasing in duration since 3 months. No history of precedent trauma. Radiological imaging with radiographs showed suspicious lytic lesion in lateral femoral condyle. MRI scan was done.On biopsy, histopathological evaluation showed presence of characteristic multinucleated giant-cells. After confirmation, tumor en bloc resection was done, followed by chemical cauterization with 5 % phenol. Articular margins were realigned under direct vision and fixed with 1.8 mm threaded K wires. PMMA cementing in bone defect was done after achieving adequate hemostasis. At two years follow-up, patient had good result in terms of pain, knee range of motion and weight bearing. Conclusion: Combination treatment of radical curettage, phenol irrigation, electrocautery and cementation is effective in preventing local recurrence. This can replace en bloc resection with a wide margin. Using subchondral threaded Kirschner wires to maintain articular margins is cheap alternative to costly implants in economically underprivileged patients. PMID:29181359
Bose, Susmita; Tarafder, Solaiman; Bandyopadhyay, Amit
2017-01-01
The functionality or survival of tissue engineering constructs depends on the adequate vascularization through oxygen transport and metabolic waste removal at the core. This study reports the presence of magnesium and silicon in direct three dimensional printed (3DP) tricalcium phosphate (TCP) scaffolds promotes in vivo osteogenesis and angiogenesis when tested in rat distal femoral defect model. Scaffolds with three different interconnected macro pore sizes were fabricated using direct three dimensional printing. In vitro ion release in phosphate buffer for 30 days showed sustained Mg 2+ and Si 4+ release from these scaffolds. Histolomorphology and histomorphometric analysis from the histology tissue sections revealed a significantly higher bone formation, between 14 and 20% for 4-16 weeks, and blood vessel formation, between 3 and 6% for 4-12 weeks, due to the presence of magnesium and silicon in TCP scaffolds compared to bare TCP scaffolds. The presence of magnesium in these 3DP TCP scaffolds also caused delayed TRAP activity. These results show that magnesium and silicon incorporated 3DP TCP scaffolds with multiscale porosity have huge potential for bone tissue repair and regeneration.
Precision of computer-assisted core decompression drilling of the knee.
Beckmann, J; Goetz, J; Bäthis, H; Kalteis, T; Grifka, J; Perlick, L
2006-06-01
Core decompression by exact drilling into the ischemic areas is the treatment of choice in early stages of osteonecrosis of the femoral condyle. Computer-aided surgery might enhance the precision of the drilling and lower the radiation exposure time of both staff and patients. The aim of this study was to evaluate the precision of the fluoroscopically based VectorVision-navigation system in an in vitro model. Thirty sawbones were prepared with a defect filled up with a radiopaque gypsum sphere mimicking the osteonecrosis. 20 sawbones were drilled by guidance of an intraoperative navigation system VectorVision (BrainLAB, Munich, Germany). Ten sawbones were drilled by fluoroscopic control only. A statistically significant difference with a mean distance of 0.58 mm in the navigated group and 0.98 mm in the control group regarding the distance to the desired mid-point of the lesion could be stated. Significant difference was further found in the number of drilling corrections as well as radiation time needed. The fluoroscopic-based VectorVision-navigation system shows a high feasibility and precision of computer-guided drilling with simultaneously reduction of radiation time and therefore could be integrated into clinical routine.
Bose, Susmita; Tarafder, Solaiman; Bandyopadhyay, Amit
2016-01-01
The functionality or survival of tissue engineering constructs depends on the adequate vascularization through oxygen transport and metabolic waste removal at the core. This study reports the presence of magnesium and silicon in 3D printed tricalcium phosphate (TCP) scaffolds promotes in vivo osteogenesis and angiogenesis when tested in rat distal femoral defect model. Scaffolds with three different interconnected macro pore sizes were fabricated using direct three dimensional printing (3DP). In vitro release in phosphate buffer for 30 days showed sustained Mg2+ and Si4+ release from these scaffolds. Histolomorphology and histomorphometric analysis from the histology tissue sections revealed a significantly higher bone, between 14 and 20 % for 4 to 16 weeks, and blood vessel, between 3 and 6% for 4 to 12 weeks, formation due to the presence of magnesium and silicon in TCP scaffolds compared to bare TCP scaffolds. The presence of magnesium in these 3DP TCP scaffolds also caused delayed TRAP activity. These results show that magnesium and silicon incorporated 3DP TCP scaffolds with multiscale porosity have huge potential for bone tissue repair and regeneration. PMID:27287311
Hyaline cartilage degenerates after autologous osteochondral transplantation.
Tibesku, C O; Szuwart, T; Kleffner, T O; Schlegel, P M; Jahn, U R; Van Aken, H; Fuchs, S
2004-11-01
Autologous osteochondral grafting is a well-established clinical procedure to treat focal cartilage defects in patients, although basic research on this topic remains sparse. The aim of the current study was to evaluate (1) histological changes of transplanted hyaline cartilage of osteochondral grafts and (2) the tissue that connects the transplanted cartilage with the adjacent cartilage in a sheep model. Both knee joints of four sheep were opened surgically and osteochondral grafts were harvested and simultaneously transplanted to the contralateral femoral condyle. The animals were sacrificed after three months and the received knee joints were evaluated histologically. Histological evaluation showed a complete ingrowth of the osseous part of the osteochondral grafts. A healing or ingrowth at the level of the cartilage could not be observed. Histological evaluation of the transplanted grafts according to Mankin revealed significantly more and more severe signs of degeneration than the adjacent cartilage, such as cloning of chondrocytes and irregularities of the articular surface. We found no connecting tissue between the transplanted and the adjacent cartilage and histological signs of degeneration of the transplanted hyaline cartilage. In the light of these findings, long-term results of autologous osteochondral grafts in human beings have to be followed critically.
Femoral Head Avascular Necrosis Is Not Caused by Arthroscopic Posterolateral Femoroplasty.
Rupp, Robert E; Rupp, Sasha N
2016-05-01
This study was conducted to identify the risk of avascular necrosis of the femoral head after arthroscopic femoroplasty extending to the posterolateral femoral neck, the source of the primary blood supply to the femoral head. Cam lesions of femoroacetabular impingement are typically anterior along the junction of the femoral head and neck. However, anatomic variations can involve the posterolateral vascular region of the femoral head and neck. Femoroplasty involving this vascular region can lead to injury to the blood supply to the femoral head, with subsequent avascular necrosis. If the posterolateral portion of the cam lesion is preserved, persistent femoroacetabular impingement may occur. A retrospective review identified 112 patients who underwent arthroscopic femoroplasty for femoroacetabular impingement over a 2-year period. Of these patients, 14 had femoroplasty that extended to the posterolateral femoral head. Of this group, 5 had undergone magnetic resonance imaging (MRI) after femoroplasty and the other 9 were contacted to undergo MRI of the hip to evaluate for avascular necrosis. A radiologist and the senior author evaluated all MRI scans specifically for avascular necrosis of the femoral head. All procedures were performed by the senior author. Mean age of the 14 patients (8 women and 6 men) with femoroplasty that extended into the posterolateral vascular region of the femoral head was 44 years (range, 23-69 years). All 14 patients underwent MRI evaluation of the affected hip a mean of 25 months (range, 7-44 months) after femoroplasty. No MRI scans showed evidence of avascular necrosis of the femoral head. Femoroplasty of the posterolateral vascular region of the femoral head is not associated with avascular necrosis. Patients with femoroacetabular impingement and a cam lesion extending to the posterolateral femoral head can undergo femoroplasty of this region without the development of avascular necrosis. [Orthopedics. 2016; 39(3):177-180.]. Copyright 2016, SLACK Incorporated.
Adhikari, Srikar; Zeger, Wes; Thom, Christopher; Fields, J Matthew
2015-09-01
Two-point compression ultrasonography focuses on the evaluation of common femoral and popliteal veins for complete compressibility. The presence of isolated thrombi in proximal veins other than the common femoral and popliteal veins should prompt modification of 2-point compression technique. The objective of this study is to determine the prevalence and distribution of deep venous thrombi isolated to lower-extremity veins other than the common femoral and popliteal veins in emergency department (ED) patients with clinically suspected deep venous thrombosis. This was a retrospective study of all adult ED patients who received a lower-extremity venous duplex ultrasonographic examination for evaluation of deep venous thrombosis during a 6-year period. The ultrasonographic protocol included B-mode, color-flow, and spectral Doppler scanning of the common femoral, femoral, deep femoral, popliteal, and calf veins. Deep venous thrombosis was detected in 362 of 2,451 patients (14.7%; 95% confidence interval [CI] 13.3% to 16.1%). Thrombus confined to the common femoral vein alone was found in 5 of 362 cases (1.4%; 95% CI 0.2% to 2.6%). Isolated femoral vein thrombus was identified in 20 of 362 patients (5.5%; 95% CI 3.2% to 7.9%). Isolated deep femoral vein thrombus was found in 3 of 362 cases (0.8%; 95% CI -0.1% to 1.8%). Thrombus in the popliteal vein alone was identified in 53 of 362 cases (14.6%; 95% CI 11% to 18.2%). In our study, 6.3% of ED patients with suspected deep venous thrombosis had isolated thrombi in proximal veins other than common femoral and popliteal veins. Our study results support the addition of femoral and deep femoral vein evaluation to standard compression ultrasonography of the common femoral and popliteal vein, assuming that this does not have a deleterious effect on specificity. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Okamoto, Shigetoshi; Mizu-uchi, Hideki; Okazaki, Ken; Hamai, Satoshi; Tashiro, Yasutaka; Nakahara, Hiroyuki; Iwamoto, Yukihide
2016-01-01
The first purpose of this study was to compare the reproducibility of two-dimensional (2D) and three-dimensional (3D) measurements for preoperative planning of the femoral side in total knee arthroplasty (TKA). The second purpose was to evaluate the factors affecting the differences between the 2D and 3D measurements. Two-dimensional and 3D measurements for preoperative planning of the femoral side in TKA were evaluated in 75 varus knees with osteoarthritis. The femoral valgus angle, defined as the angle between the mechanical and anatomical axes of the femur, and the clinical rotation angle and surgical rotation angle, defined by the angles between the posterior condylar line and the clinical or surgical transepicondylar axes, respectively, were analysed using 2D (radiographs and axial CT slices) and 3D (3D bone models reconstructed from CT images) measurements. For all variables, 3D measurements were more reliable and reproducible than 2D measurements. The medians and ranges of the clinical rotation angle and surgical rotation angle were 6.6° (-1.7° to 12.1°) and 2.3° (-2.5° to 8.6°) in 2D, and 7.1° (2.7° to 11.4°) and 3.0° (-2.0° to 7.5°) in 3D. Varus/valgus alteration of the CT scanning direction relative to the mechanical axis affected the difference in clinical rotation angles between 2D and 3D measurements. Significantly, smaller values of the clinical rotation angle and surgical rotation angle were obtained by 2D compared to 3D measurements, which could result in internal rotation of the femoral component even if the surgeon performs the bone cutting precisely. Regarding clinical relevance, first, this study confirmed the reliability of 3D measurements. Second, it underscored the risk of internal rotation of the femoral component when using 2D measurement, even with precise bone cutting technique. These results will help surgeons avoid malpositioning of the femoral component if 2D measurements are used for preoperative planning in TKA. Prospective comparative study, Level Ш.
Cruz, Aristides I; Lakomkin, Nikita; Fabricant, Peter D; Lawrence, J Todd R
2016-06-01
Most studies examining the safety and efficacy of transphyseal anterior cruciate ligament (ACL) reconstruction for skeletally immature patients utilize transtibial drilling. Independent femoral tunnel drilling may impart a different pattern of distal femoral physeal involvement. To radiographically assess differences in distal femoral physeal disruption between transtibial and independent femoral tunnel drilling. We hypothesized that more oblique tunnels associated with independent drilling involve a significantly larger area of physeal disruption compared with vertically oriented tunnels. Cross-sectional study; Level of evidence, 3. We analyzed skeletally immature patients aged between 10 and 15 years who underwent transphyseal ACL reconstruction utilizing an independent femoral tunnel drilling technique between January 1, 2008, and March 31, 2011. These patients were matched with a transtibial technique cohort based on age and sex. Radiographic measurements were recorded from preoperative magnetic resonance imaging and postoperative radiographs. Ten patients in each group were analyzed. There were significant differences between independent drilling and transtibial drilling cohorts in the estimated area of physeal disruption (1.64 vs 0.74 cm(2); P < .001), femoral tunnel angles (32.1° vs 72.8°; P < .001), and medial/lateral location of the femoral tunnel (24.2 vs 36.1 mm from lateral cortex; P = .001), respectively. There was a significant inverse correlation between femoral tunnel angle and estimated area of distal femoral physeal disruption (r = -0.8255, P = .003). Femoral tunnels created with an independent tunnel drilling technique disrupt a larger area of the distal femoral physis and create more eccentric tunnels compared with a transtibial technique. As most studies noting the safety of transphyseal ACL reconstruction have utilized a central, vertical femoral tunnel, surgeons should be aware that if an independent femoral tunnel technique is utilized during transphyseal ACL reconstruction, more physeal tissue is at risk and tunnels are more eccentrically placed across the physis when drilling at more horizontal angles. Prior studies have shown that greater physeal involvement and eccentric tunnels may increase the risk of growth disturbance.
Kort, N P; van Raay, J J A M; Thomassen, B J W
2007-08-01
Use of an intramedullary rod is advised for the alignment of the femoral component of an Oxford phase-III prosthesis. There are users moving toward extramedullary alignment, which is merely an indicator of frustration with accuracy of intramedullary alignment. The results of our study with 10 cadaver femora demonstrate that use of a short and long intramedullary femoral rod may result in excessive flexion alignment error of the femoral component. Understanding of the extramedullary alignment possibility and experience with the visual alignment of the femoral drill guide is essential toward minimizing potential errors in the alignment of the femoral component.
Lubowitz, James H; Konicek, John
2010-10-01
The purpose was to measure anterior cruciate ligament (ACL) femoral tunnel lengths comparing anteromedial (AM) portal and outside-in techniques. ACL femoral guide pins were drilled into 12 cadaveric knees through the AM portal technique and then the outside-in technique in each specimen. Pin intraosseous distance was measured in millimeters by a MicroScribe 3-dimensional digitizer (Immersion, San Jose, CA). With the AM portal technique, the mean ACL femoral tunnel distance was 30.5 mm. With the outside-in technique, the mean ACL femoral tunnel distance was 34.1 mm. The difference was statistically significant (P = .04). Our results show that the outside-in technique for creating the ACL femoral tunnel results in a longer mean tunnel length than the AM portal technique for creating the ACL femoral tunnel. The outside-in technique best prevents excessively short tunnels. Our results have clinical relevance for surgeons who desire to perform independent, rather than transtibial, drilling of the ACL femoral tunnel and desire adequate length of tendon graft within the femoral bone tunnel. Copyright © 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Femoral head shape differences during development may identify hips at risk of degeneration.
Vanden Berg-Foels, Wendy S; Schwager, Steven J; Todhunter, Rory J; Reeves, Anthony P
2011-12-01
Developmental dysplasia of the hip (DDH) is a common cause of elevated contact stress and early onset osteoarthritis (OA). We hypothesized that adaptation to focal loading during postnatal development would result in signature changes to the shape of the femoral head secondary center of ossification (SCO). SCO shape was evaluated in a canine model of DDH at ages 14 and 32 weeks. The evolving 3D morphology of the SCO was captured using serial quantitative computed tomography. A discrete medial representation shape model was fit to each SCO and served as the basis for quantitative thickness and bending measurements. Shape measurements were tested for associations with hip subluxation and degeneration. At 32 weeks, the SCO was thinner (flatter) in the perifoveal region, the site of focal loading; a greater bend to the SCO was present lateral to the site of thinning; SCO thinning and bending were associated with less femoral head coverage and with a higher probability of degeneration. Shape changes were not detected at 14 weeks. Measurement and visualization of SCO shape changes due to altered loading may provide a basis for identifying hips at risk of early onset OA and a tool for surgical planning of hip restructuring.
Femoral condyle curvature is correlated with knee walking kinematics in ungulates.
Sylvester, Adam D
2015-12-01
The knee has been the focus of many studies linking mammalian postcranial form with locomotor behaviors and animal ecology. A more difficult task has been linking joint morphology with joint kinematics during locomotor tasks. Joint curvature represents one opportunity to link postcranial morphology with walking kinematics because joint curvature develops in response to mechanical loading. As an initial examination of mammalian knee joint curvature, the curvature of the medial femoral condyle was measured on femora representing 11 ungulate species. The position of a region of low curvature was measured using a metric termed the "angle to low curvature". This low-curvature region is important because it provides the greatest contact area between femoral and tibial condyles. Kinematic knee angles during walking were derived from the literature and kinematic knee angles across the gait cycle were correlated with angle to low curvature values. The highest correlation between kinematic knee angle and the angle to low curvature metric occurred at 20% of the walking gait cycle. This early portion of the walking gait cycle is associated with a peak in the vertical ground reaction force for some mammals. The chondral modeling theory predicts that frequent and heavy loading of particular regions of a joint surface during ontogeny will result in these regions being flatter than the surrounding joint surface. The locations of flatter regions of the femoral condyles of ungulates, and their association with knee angles used during the early stance phase of walking provides support for the chondral modeling theory. © 2015 Wiley Periodicals, Inc.
Using Ultrasound to Enhance Medical Students' Femoral Vascular Physical Examination Skills.
Ahn, Justin S; French, Andrew J; Thiessen, Molly E W; Browne, Vaughn; Deutchman, Mark; Guiton, Gretchen; Madigosky, Wendy; Kendall, John L
2015-10-01
To determine whether the addition of ultrasound to traditional physical examination instruction improves junior medical students' abilities to locate the femoral pulse. Initially, 150 second-year medical students were taught the femoral pulse examination using traditional bedside teaching on standardized patients and online didactic videos. Students were then randomized into 2 groups: group 1 received ultrasound training first and then completed the standardized examination; and group 2 performed the standardized examination first and then received ultrasound training. On the standardized patients, the femoral artery was marked with invisible ink before the sessions using ultrasound. Compared to these markers, students were then evaluated on the accuracy of femoral artery pulse palpation and the estimated location of the femoral vein. All students completed a self-assessment survey after the ultrasound sessions. Ultrasound training improved the students' ability to palpate the femoral pulse (P= .02). However, ultrasound did not facilitate correct estimation of the femoral vein's anatomic location (P = .09). Confidence levels in localizing the femoral artery and vein were equal between groups at baseline, and both increased after the ultrasound sessions. The addition of ultrasound teaching to traditional physical examination instruction enhanced medical student competency and confidence with the femoral vascular examination. However, understanding of anatomy may require emphasis on precourse didactic material, but further study is required. © 2015 by the American Institute of Ultrasound in Medicine.
[Isolated true aneurysm of the deep femoral artery].
Salomon du Mont, L; Holzer, T; Kazandjian, C; Saucy, F; Corpataux, J M; Rinckenbach, S; Déglise, S
2016-07-01
Aneurysms of the deep femoral artery, accounting for 5% of all femoral aneurysms, are uncommon. There is a serious risk of rupture. We report the case of an 83-year-old patient with a painless pulsatile mass in the right groin due to an aneurysm of the deep femoral artery. History taking revealed no cardiovascular risk factors and no other aneurysms at other localizations. The etiology remained unclear because no recent history of local trauma or puncture was found. ACT angiography was performed, revealing a true isolated aneurysm of the deep femoral artery with a diameter of 90mm, beginning 1cm after its origin. There were no signs of rupture or distal emboli. Due to unsuitable anatomy for an endovascular approach, the patient underwent open surgery, with exclusion of the aneurysm and interposition of an 8-mm Dacron graft to preserve deep femoral artery flow. Due to their localization, the diagnosis and the management of aneurysms of the deep femoral artery can be difficult. Options are surgical exclusion or an endovascular approach in the absence of symptoms or as a bridging therapy. If possible, blood flow to the distal deep femoral artery should be maintained, the decision depending also on the patency of the superficial femoral artery. In case of large size, aneurysms of the deep femoral artery should be treated without any delay. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Chang, N-J; Lam, C-F; Lin, C-C; Chen, W-L; Li, C-F; Lin, Y-T; Yeh, M-L
2013-10-01
Repairing articular cartilage is clinically challenging. We investigated a simple, effective and clinically feasible cell-based therapeutic approach using a poly(lactide-co-glycolide) (PLGA) scaffold seeded with autologous endothelial progenitor cells (EPC) to repair a full-thickness osteochondral defect in rabbits using a one-step surgery. EPC obtained by purifying a small amount of peripheral blood from rabbits were seeded into a highly porous, biocompatible PLGA scaffold, namely, EPC-PLGA, and implanted into the osteochondral defect in the medial femoral condyle. Twenty two rabbits were randomized into one of three groups: the empty defect group (ED), the PLGA-only group or the EPC-PLGA group. The defect sites were evaluated 4 and 12 weeks after implantation. At the end of testing, only the EPC-PLGA group showed the development of new cartilage tissue with a smooth, transparent and integrated articular surface. Moreover, histological analysis showed obvious differences in cartilage regeneration. At week 4, the EPC-PLGA group showed considerably higher TGF-β2 and TGF-β3 expression, a greater amount of synthesized glycosaminoglycan (GAG) content, and a higher degree of osteochondral angiogenesis in repaired tissues. At week 12, the EPC-PLGA group showed enhanced hyaline cartilage regeneration with a normal columnar chondrocyte arrangement, higher SOX9 expression, and greater GAG and collagen type II (COLII) content. Moreover, the EPC-PLGA group showed organized osteochondral integration, the formation of vessel-rich tubercular bone and significantly higher bone volume per tissue volume and trabecular thickness (Tb.Th). The present EPC-PLGA cell delivery system generates a suitable in situ microenvironment for osteochondral regeneration without the supplement of exogenous growth factors. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Mohseni, Mahmoud; Jahandideh, Alireza; Abedi, Gholamreza; Akbarzadeh, Abolfazl; Hesaraki, Saeed
2018-03-01
Bone regeneration is an important objective in clinical practice and has been used for different applications. The aim of this study was to evaluate the effectiveness of nanocomposite tricalcium phosphate (TCP)/collagen scaffolds combined with hydroxyapatite scaffold for bone healing in surgery of femoral defects in rabbits. In this study, 45 mature male New Zealand white rabbits between 6 and 8 months old and weighting between 3 and 3.5 kg were examined. Rabbits were divided into three groups. Surgical procedures were performed after intramuscular injection of Ketamine 10% (ketamine hydrochloride, 50 mg/kg) and Rompun 5% (xylazine, 5 mg/kg). Then an approximately 6 mm diameter-5 mm cylinder bone defect was created in the femur of one of the hind limbs. After inducing the surgical wound, all rabbits were coloured and randomly divided into three experimental groups of 15 animals each. Group 1 received pure medical nanocomposite TCP/collagen granules, group 2 received hydroxyapatite, and third group was a control group which received no treatment. Histopathological evaluation was performed on days 15, 30, and 45 after surgery. On days 15, 30, and 45 after surgery, the quantity and the velocity of stages of bone formation at the healing site in nanocomposite TCP/collagen group were better than HA and control groups and the quantity of newly formed lamellar bone at the healing site in nanocomposite TCP/collagen group were better than onward compared with HA and control groups. In conclusion, it seems that TCP/collagen nanocomposite has a significant role in the reconstruction of bone defects and can be used as scaffold in bone fractures.
21 CFR 888.3570 - Knee joint femoral (hemi-knee) metallic uncemented prosthesis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femoral (hemi-knee) metallic uncemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3570 Knee joint femoral (hemi-knee) metallic uncemented prosthesis. (a) Identification. A knee joint femoral (hemi-knee...
21 CFR 888.3400 - Hip joint femoral (hemi-hip) metallic resurfacing prosthesis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic resurfacing... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3400 Hip joint femoral (hemi-hip) metallic resurfacing prosthesis. (a) Identification. A hip joint femoral (hemi-hip...
Dewi, Anne Handrini; Ana, Ika Dewi; Wolke, Joop; Jansen, John
2015-10-01
Gypsum or calcium sulfate (CS) or plaster of Paris (POP) is considered as a fast degradable material that usually resorbs before the bone defect area is completely filled by new bone. In this study, the incorporation of CaCO3 hydrogel into POP in different compositions was proposed to enhance the bone biological activity of POP and to decrease its degradability. The mechanical and degradation properties of the various materials were characterized by in vitro analysis. Subsequently, the materials were inserted into cylindrically sized bone defects as created into the femoral condyle of rats and left in situ for 1, 4, and 8 weeks. Histological analysis of the retrieved specimens indicated that the addition of CaCO3 hydrogel into POP increased bone formation, angiogenesis and collagen density and resulted into faster bone formation and maturation. It was also confirmed that the degradation rate of the POP decreased by the addition of CaCO3 hydrogel. The in vivo findings did corroborate with the in vitro analysis. In conclusion, the incorporation of CaCO3 hydrogel provides a promising technology to improve the properties of POP, the oldest biomaterial used for bone grafting. © 2015 Wiley Periodicals, Inc.
Babis, G C; Sakellariou, V I; Chatziantoniou, A N; Soucacos, P N; Megas, P
2011-12-01
We report the results of 62 hips in 62 patients (17 males, 45 females) with mean age of 62.4 years (37 to 81), who underwent revision of the acetabular component of a total hip replacement due to aseptic loosening between May 2003 and November 2007. All hips had a Paprosky type IIIa acetabular defect. Acetabular revision was undertaken using a Procotyl E cementless oblong implant with modular side plates and a hook combined with impaction allografting. At a mean follow-up of 60.5 months (36 to 94) with no patients lost to follow-up and one died due to unrelated illness, the complication rate was 38.7%. Complications included aseptic loosening (19 hips), deep infection (3 hips), broken hook and side plate (one hip) and a femoral nerve palsy (one hip). Further revision of the acetabular component was required in 18 hips (29.0%) and a further four hips (6.4%) are currently loose and awaiting revision. We observed unacceptably high rates of complication and failure in our group of patients and cannot recommend this implant or technique.
Mishima, Hajime; Sakai, Shinsuke; Uemura, Toshimasa
2013-01-01
Objective: The purpose of this study was to evaluate the long-term results of cartilage repair after allogeneic transplantation of cartilaginous aggregates formed from bone marrow–derived cells. Methods: Bone marrow cells were harvested from 12-day-old rabbits. The cells were subjected to a monolayer culture, and the spindle-shaped cells attached to the flask surface were defined as bone marrow–derived mesenchymal cells. After the monolayer culture, a 3-dimensional cartilaginous aggregate was formed using a bioreactor with chondrogenesis. We created osteochondral defects, measuring 5 mm in diameter and 4 mm in depth, at the femoral trochlea of 10-week-old rabbits. Two groups were established, the transplanted group in which the cartilaginous aggregate was transplanted into the defect, and the control group in which the defect was left untreated. Twenty-six and 52 weeks after surgery, the rabbits were sacrificed and their tissue repair status was evaluated macroscopically (International Cartilage Repair Society [ICRS] score) and histologically (O’Driscoll score). Results: The ICRS scores were as follows: at week 26, 7.2 ± 0.5 and 7.6 ± 0.8; at week 52, 7.6 ± 1.1 and 9.7 ± 0.7, for the transplanted and control groups, respectively. O’Driscoll scores were as follows: at week 26, 12.6 ± 1.9 and 10.1 ± 1.9; at week 52, 9.6 ± 3.0 and 14.0 ± 1.4, each for transplanted and control groups, respectively. No significant differences were observed between the groups. Conclusions: This study demonstrates that allogeneic transplantation of cartilaginous aggregates formed from bone marrow–derived cells produces comparable long-term results based on macroscopic and histological outcome measures when compared with osteochondral defects that are left untreated. PMID:26069678
Liu, Jing; You, Xiao-hua; Zhao, Xian-xian; Hu, Jian-qiang; Cao, Jiang; Xu, Rong-liang; Wu, Hong; Chen, Shao-ping; Zhang, Jian-liang; Zheng, Xing; Qin, Yong-wen
2010-04-01
To evaluate the efficacy and adverse effects of transcatheter closure of perimembranous ventricular septal defect (pmVSD) with modified double-disk occluder device (MDVO). Clinical data including clinical examination, electrocardiography daily after the procedure for a week, chest-X-rays and TTE before discharge and at 3-5 days after the procedure were analyzed from 604 patients underwent percutaneous closure of a pmVSD with MDVO at our department between December 2001 and December 2008. Procedure was successful in 576 out of 604 patients (95.4%) and 583 VSD occluders were placed. Endocarditis, thromboembolism, or deaths were not observed after procedure. Conduction block occurred in 81 patients (56 RBBB, 14 LBBB) and transient nonparoxysmal ventricular tachycardia in 31 patients after the procedure. Complete heart block occurred in 11 patients, 9 of them recovered in 3 weeks, permanent pacemaker was implanted in 2 patients (one had transient III degrees AVB before the procedure, the other underwent simultaneous closure of ventricular septal defect and atrial septal defect). Trivial/small residual shunts were found in 69 patients (12.0%). The residual shunts disappeared in 31 patients and remained unchanged in 38 patients (6.6%) 7 days after procedures. Aortic regurgitation developed in 5 patients (2 trivial/small, 3 small/moderate), and tricuspid regurgitation was present in 35 patients (32 trivial/small, 3 moderate). Five patients developed haemolysis (device retrieved via catheter in 1 patient due to persistent haemolysis, the other 4 patients recovered 3-14 days post procedure). Pseudoaneurysm of femoral artery occurred in 1 patient, and disappeared by pressure dressing. Device was successfully replaced in 2 patients with either device embolization (n = 1) or device misplacement (n = 1) after device retrieval by catheter. It is safe and effective to close congenital perimembranous ventricular septal defect with domestic-made occluder device.
Chang, Bei; Song, Wen; Han, Tianxiao; Yan, Jun; Li, Fuping; Zhao, Lingzhou; Kou, Hongchao; Zhang, Yumei
2016-03-01
The present work assesses the potential of three-dimensional (3D) porous titanium (pore size of 188-390 μm and porosity of 70%) fabricated by vacuum diffusion bonding of titanium meshes for applications in bone engineering. Rat bone marrow mesenchymal stem cells were used to investigate the proliferation and differentiation of cells on titanium scaffolds with different pore sizes at day 7, day 14 and day 21 based on DNA contents, alkaline phosphatase (ALP) activity, collagen (COL) secretion and osteogenic gene expressions including ALP, COL-1, bone morphogenetic protein-2 (BMP-2), osteopontin (OPN), runt-related transcription factor 2 (RUNX2), using smooth solid titanium plate as reference material. The rabbit models with distal femoral condyles defect were used to investigate the bone ingrowth into the porous titanium. All samples were subjected to Micro-CT and histological analysis after 4 and 12 weeks of healing. A one-way ANOVA followed by Tukey post hoc tests was used to analyze the data. It was found that the differentiation stage of cells on the porous titanium delayed compared with the smooth solid titanium plate and Ti 188 was more inclined to promote cell differentiation at the initial stage (day 14) while cell proliferation (day 1, 4, 7, 10, 14 and 21) and bone ingrowth (4 and 12 weeks) were biased to Ti 313 and Ti 390. The study indicates that the hybrid porous implant design which combines the advantages of different pore sizes may be meaningful and promising for bone defect restoration. One of the significant challenges in bone defect restoration is the integration of biomaterials and surrounding bone tissue. Porous titanium may be a promising choice for bone ingrowth and mineralization with appropriate mechanical and biological properties. In this study, based on porous titanium fabricated by vacuum diffusion bonding of titanium meshes, we have evaluated the influence of various pore sizes on rat bone marrow mesenchymal stem cells (rBMMSCs) penetration in vitro and bone ingrowth in vivo. It was interesting that we found the proliferation and differentiation abilities of rBMMSCs, as well as bone ingrowth were related to different pore sizes of such porous scaffolds. The results may provide guidance for porous titanium design for bone defect restoration. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Curate, F; Umbelino, C; Perinha, A; Nogueira, C; Silva, A M; Cunha, E
2017-11-01
The assessment of sex is of paramount importance in the establishment of the biological profile of a skeletal individual. Femoral relevance for sex estimation is indisputable, particularly when other exceedingly dimorphic skeletal regions are missing. As such, this study intended to generate population-specific osteometric models for the estimation of sex with the femur and to compare the accuracy of the models obtained through classical and machine-learning classifiers. A set of 15 standard femoral measurements was acquired in a training sample (100 females; 100 males) from the Coimbra Identified Skeletal Collection (University of Coimbra, Portugal) and models for sex classification were produced with logistic regression (LR), linear discriminant analysis (LDA), support vector machines (SVM), and reduce error pruning trees (REPTree). Under cross-validation, univariable sectioning points generated with REPTree correctly estimated sex in 60.0-87.5% of cases (systematic error ranging from 0.0 to 37.0%), while multivariable models correctly classified sex in 84.0-92.5% of cases (bias from 0.0 to 7.0%). All models were assessed in a holdout sample (24 females; 34 males) from the 21st Century Identified Skeletal Collection (University of Coimbra, Portugal), with an allocation accuracy ranging from 56.9 to 86.2% (bias from 4.4 to 67.0%) in the univariable models, and from 84.5 to 89.7% (bias from 3.7 to 23.3%) in the multivariable models. This study makes available a detailed description of sexual dimorphism in femoral linear dimensions in two Portuguese identified skeletal samples, emphasizing the relevance of the femur for the estimation of sex in skeletal remains in diverse conditions of completeness and preservation. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
Bioactive scaffold for bone tissue engineering: An in vivo study
NASA Astrophysics Data System (ADS)
Livingston, Treena Lynne
Massive bone loss of the proximal femur is a common problem in revision cases of total hip implants. Allograft is typically used to reconstruct the site for insertion of the new prosthesis. However, for long term fixation and function, it is desirable that the allograft becomes fully replaced by bone tissue and aids in the regeneration of bone to that site. However, allograft use is typically associated with delayed incorporation and poor remodeling. Due to these profound limitations, alternative approaches are needed. Tissue engineering is an attractive approach to designing improved graft materials. By combining osteogenic activity with a resorbable scaffold, bone formation can be stimulated while providing structure and stability to the limb during incorporation and remodeling of the scaffold. Porous, surface modified bioactive ceramic scaffolds (pSMC) have been developed which stimulate the expression of the osteoblastic phenotype and production of bone-like tissue in vitro. The scaffold and two tissue-engineered constructs, osteoprogenitor cells seeded onto scaffolds or cells expanded in culture to form bone tissue on the scaffolds prior to implantation, were investigated in a long bone defect model. The rate of incorporation was assessed. Both tissue-engineered constructs stimulated bone formation and comparable repair at 2 weeks. In a rat femoral window defect model, bone formation increased over time for all groups in concert with scaffold resorption, leading to a 40% increase in bone and 40% reduction of the scaffold in the defect by 12 weeks. Both tissue-engineered constructs enhanced the rate of mechanical repair of long bones due to better bony union with the host cortex. Long bones treated with tissue engineered constructs demonstrated a return in normal torsional properties by 4 weeks as compared to 12 weeks for long bones treated with pSMC. Culture expansion of cells to produce bone tissue in vitro did not accelerate incorporation over the treatment with cells seeded at the time of surgery. Porous, surface modified bioactive ceramic is a promising scaffold material for tissue-engineered bone repair. Bone formation and scaffold resorption act in concert for maintenance and improvement of the structural properties of the long bones over time. As determined histomorphometrically and mechanically, the rate of incorporation of the scaffold was enhanced with the tissue-engineered constructs.
Kovanda, M; Havlícek, V; Hudec, J
2009-04-01
PURPOSE OF THE STUDY The mid-term longevity of femoral components varies considerably, with some showing failure due to early aseptic loosening. Since the hip joint is subject to heavy mechanical loads, it can be assumed that the mechanical interaction of the implant, bone cement and femur will play a key role in the resultant reliability of an arthroplasty. This study was designed to examine this mechanical interaction in four femoral components different in construction (Poldi-Cech, CF-30, MS-30 and PFC) using mathematical simulation. MATERIAL AND METHODS Four stem/cement/femur 3-D mathematical models, comparable in quality, infolving the Poldi-Cech, CF-30, MS-30 and PFC stems, respectively, were constructed. A 3-D model for each stem was created according to its real, middle-size femoral component. Each 3-D model of the cement mantle corresponded in shape to the mantle of the appropriate real stem, with its thickness based on the recommended values of 4-7 mm in the proximal and 1-3 mm in the distal part, and with the cement mantle reaching as far as 10 mm distal to the femoral stem tip. For simplicitys sake the outer surface of the cement mantle was simulated as smooth. A 3-D model involving the proximal epiphysis and the metaphysis of a femur was reconstructed, based on a series of CT cross-sections obtained periodically at 10.5-mm and 2.5-mm distances. The sten/cement/femur model with the MS-30 stem also included a centraliser. The mechanical interaction of the stem, bone cement and bone tissue was examined by means of mathematical stimulation using ANSYS 5.7 software based on finite element analysis. RESULTS For the sake of simplicity, only two key parameters are presented, namely, contact stress at the stem-cement interface and equivalent deformation in the stem/cement/femur system. The least satisfactory stress loading was in the CF-30 stem whose sharp edges showed the values of contact stress about six-times higher than on the mid-medial portion of the stem, with the sharp edges behaving as stress concentrators. A satisfactory stress loading was found in Poldi-Cech, MS-30 and PFC stems, in which contact stress was evenly distributed along the whole lenght of the stem and the values at the edges and on the midmedial portion did not differ much. DISCUSSION The distribution of contact stress is one of the most important factors for the long-term longevity of implants. It was found least satisfactory in the CF-30 stem whose sharp edges act as stress condenser adversely affecting not only the stemcement interface, but also the resultant stress distribution within the femur. The most satisfactory results of stress distribution were recorded in the Poldi-Cech and MS-30 stems. The PFC stem also responded satisfactorily to the simulated stress loading. However, on loading whose substantial part would be torsion, the stems circular or oval cross-section could interfere with rotation stability of the implant; but this was impossible to detect by the mathematical simulation used in this study. CONCLUSIONS The results presented here show that, in the Poldi-Cech, CF-30, MS-30 and PFC femoral stems, a good agreement was achieved between the results of their clinical application and those of mathematical modelling of their mechanical properties. It can be concluded that mechanical interaction among the femoral stem, cement mantle and bone tissue plays the key role in the long-term longevity of such an implant. Key words: Poldi-Cech, CF-30, MS-30, PFC, mechanical interaction, contact stress.
Tyrosine kinase inhibitor NVP-BGJ398 functionally improves FGFR3-related dwarfism in mouse model.
Komla-Ebri, Davide; Dambroise, Emilie; Kramer, Ina; Benoist-Lasselin, Catherine; Kaci, Nabil; Le Gall, Cindy; Martin, Ludovic; Busca, Patricia; Barbault, Florent; Graus-Porta, Diana; Munnich, Arnold; Kneissel, Michaela; Di Rocco, Federico; Biosse-Duplan, Martin; Legeai-Mallet, Laurence
2016-05-02
Achondroplasia (ACH) is the most frequent form of dwarfism and is caused by gain-of-function mutations in the fibroblast growth factor receptor 3-encoding (FGFR3-encoding) gene. Although potential therapeutic strategies for ACH, which aim to reduce excessive FGFR3 activation, have emerged over many years, the use of tyrosine kinase inhibitor (TKI) to counteract FGFR3 hyperactivity has yet to be evaluated. Here, we have reported that the pan-FGFR TKI, NVP-BGJ398, reduces FGFR3 phosphorylation and corrects the abnormal femoral growth plate and calvaria in organ cultures from embryos of the Fgfr3Y367C/+ mouse model of ACH. Moreover, we demonstrated that a low dose of NVP-BGJ398, injected subcutaneously, was able to penetrate into the growth plate of Fgfr3Y367C/+ mice and modify its organization. Improvements to the axial and appendicular skeletons were noticeable after 10 days of treatment and were more extensive after 15 days of treatment that started from postnatal day 1. Low-dose NVP-BGJ398 treatment reduced intervertebral disc defects of lumbar vertebrae, loss of synchondroses, and foramen-magnum shape anomalies. NVP-BGJ398 inhibited FGFR3 downstream signaling pathways, including MAPK, SOX9, STAT1, and PLCγ, in the growth plates of Fgfr3Y367C/+ mice and in cultured chondrocyte models of ACH. Together, our data demonstrate that NVP-BGJ398 corrects pathological hallmarks of ACH and support TKIs as a potential therapeutic approach for ACH.
Reimeringer, M; Nuño, N; Desmarais-Trépanier, C; Lavigne, M; Vendittoli, P A
2013-01-01
One of the crucial factors for short- and long-term clinical success of total hip arthroplasty cementless implants is primary stability. Indeed, motion at the bone-implant interface above 40 μm leads to partial bone ingrowth, while motion exceeding 150 μm completely inhibits bone ingrowth. The aim of this study was to investigate the effect of two cementless femoral stem designs with different lengths on the primary stability. A finite element model of a composite Sawbones(®) fourth generation, implanted with five lengths of the straight prosthesis design and four lengths of the curved prosthesis design, was loaded with hip joint and abductor forces representing two physiological activities: fast walking and stair climbing. We found that reducing the straight stem length from 146 to 54 mm increased the average micromotion from 17 to 52 μm during fast walking, while the peak value increased from 42 to 104 μm. With the curved stem, reducing length from 105 to 54 mm increased the average micromotion from 10 to 29 μm, while the peak value increased from 37 to 101 μm. Similar findings are obtained for stair climbing for both stems. Although the present study showed that femoral stem length as well as stem design directly influences its primary stability, for the two femoral stems tested, length could be reduced substantially without compromising the primary stability. With the aim of minimising surgical invasiveness, newer femoral stem design and currently well performing stems might be used with a reduced length without compromising primary stability and hence, long-term survivorship.
Hori, Eisei; Kikuchi, Chigusa; Nagami, Chie; Kajikuri, Junko; Itoh, Takeo; Takeuchi, Masayoshi; Matsunaga, Tamihide
2017-11-01
A complication of diabetes mellitus is the over-production of vascular superoxides, which contribute to the development of arteriosclerosis and peripheral arterial disease (PAD). Hyperglycemia induces the formation and accumulation of advanced glycation end-products (AGEs), which in turn stimulate vascular superoxide production. The mechanism underlying AGE-mediated vascular superoxide production remains to be clarified in lower limb complications associated with diabetes. In the present study, we investigated the role of AGEs and the mitochondrial respiratory complex in superoxide production in femoral arteries using the type 2 diabetes model Otsuka Long-Evans Tokushima Fatty (OLETF) rats [vs. non-diabetic Long-Evans Tokushima Otsuka (LETO) rats]. The effects of in vivo administration of pravastatin on superoxide production in femoral arteries were also examined. Using chemiluminescent assays, luminescence microscopy, and competitive enzyme-linked immunosorbent assay (ELISA), we determined that vascular superoxide production and serum glyceraldehyde-derived AGEs (Glycer-AGEs) increased in OLETF rats. Pravastatin inhibited these responses without changing serum total cholesterol concentrations. The mitochondrial complex II inhibitor thenoyltrifluoroacetone (TTFA) also inhibited vascular superoxide production. Application of Glycer-AGEs in situ increased superoxide production in the vascular wall of femoral arteries from pravastatin-treated OLETF rats, which was then inhibited by TTFA. These results suggest that hyperglycemia increases serum Glycer-AGEs, which subsequently induce superoxide production in the femoral artery of OLETF rats in a mitochondrial complex II-dependent manner. Collectively, our results have partially elucidated the pathological mechanisms leading to diabetes-related PAD, and indicate dual beneficial actions of pravastatin for the prevention of oxidative damage to the vascular wall.
Faizan, Ahmad; Bhowmik-Stoker, Manoshi; Alipit, Vincent; Kirk, Amanda E; Krebs, Viktor E; Harwin, Steven F; Meneghini, R Michael
2017-06-01
Porous metaphyseal cones are widely used in revision knee arthroplasty. A new system of porous titanium metaphyseal cones has been designed based on the femoral and tibial morphology derived from a computed tomography-based anatomical database. The purpose of this study is to evaluate the initial mechanical stability of the new porous titanium revision cone system by measuring the micromotion under physiologic loading compared with a widely-used existing porous tantalum metaphyseal cone system. The new cones were designed to precisely fit the femoral and tibial anatomy, and 3D printing technology was used to manufacture these porous titanium cones. The stability of the new titanium cones and the widely-used tantalum cones were compared under physiologic loading conditions in bench top test model. The stability of the new titanium cones was either equivalent or better than the tantalum cones. The new titanium femoral cone construct had significantly less micromotion compared with the traditional femoral cone construct in 5 of the 12 directions measured (P < .05), whereas no statistical difference was found in 7 directions. The new porous titanium metaphyseal tibial cones demonstrated less micromotion in medial varus/valgus (P = .004) and posterior compressive micromotion (P = .002) compared with the traditional porous tantalum system. The findings of this biomechanical study demonstrate satisfactory mechanical stability of an anatomical-based porous titanium metaphyseal cone system for femoral and tibial bone loss as measured by micromotion under physiologic loading. The new cone design, in combination with instrumentation that facilitates surgical efficiency, is encouraging. Long-term clinical follow-up is warranted. Copyright © 2017 Elsevier Inc. All rights reserved.
Bone apatite composition of necrotic trabecular bone in the femoral head of immature piglets.
Aruwajoye, Olumide O; Kim, Harry K W; Aswath, Pranesh B
2015-04-01
Ischemic osteonecrosis of the femoral head (IOFH) can lead to excessive resorption of the trabecular bone and collapse of the femoral head as a structure. A well-known mineral component to trabecular bone is hydroxyapatite, which can be present in many forms due to ionic substitution, thus altering chemical composition. Unfortunately, very little is known about the chemical changes to bone apatite following IOFH. We hypothesized that the apatite composition changes in necrotic bone possibly contribute to increased osteoclast resorption and structural collapse of the femoral head. The purpose of this study was to assess the macroscopic and local phosphate composition of actively resorbed necrotic trabecular bone to isolate differences between areas of increased osteoclast resorption and normal bone formation. A piglet model of IOFH was used. Scanning electron microscopy (SEM), histology, X-ray absorbance near edge structure (XANES), and Raman spectroscopy were performed on femoral heads to characterize normal and necrotic trabecular bone. Backscattered SEM, micro-computed tomography and histology showed deformity and active resorption of necrotic bone compared to normal. XANES and Raman spectroscopy obtained from actively resorbed necrotic bone and normal bone showed increased carbonate-to-phosphate content in the necrotic bone. The changes in the apatite composition due to carbonate substitution may play a role in the increased resorption of necrotic bone due to its increase in solubility. Indeed, a better understanding of the apatite composition of necrotic bone could shed light on osteoclast activity and potentially improve therapeutic treatments that target excessive resorption of bone.
Femoral neck buttressing: a radiographic and histologic analysis.
Dixon, T; Benjamin, J; Lund, P; Graham, A; Krupinski, E
2000-10-01
To examine the incidence, radiographic and histologic findings of medial femoral neck buttressing in a consecutive group of patients undergoing total hip arthroplasty. Biomechanical parameters were evaluated on standard anteroposterior pelvic radiographs of 113 patients prior to hip replacement surgery. Demographic information on all patients was reviewed and histologic evaluation was performed on specimens obtained at the time of surgery. The incidence of medial femoral neck buttressing was found to be 50% in a consecutive series of patients undergoing total hip arthroplasty. The incidence was slightly higher in women (56% vs. 41%). Patients with buttressing had increased neck-shaft angles and smaller femoral neck diameters than were seen in patients without buttressing. Histologic evaluation demonstrated that the buttress resulted from deposition bone by the periosteum on the femoral neck in the absence of any evidence of femoral neck fracture. It would appear that femoral neck buttressing occurs in response to increased joint reactive forces seen at the hip being transmitted through the femoral neck. The increased joint reactive force can be related to the increased neck shaft angle seen in patients with buttressing.
NASA Astrophysics Data System (ADS)
Jing, Da; Tong, Shichao; Zhai, Mingming; Li, Xiaokang; Cai, Jing; Wu, Yan; Shen, Guanghao; Zhang, Xuhui; Xu, Qiaoling; Guo, Zheng; Luo, Erping
2015-11-01
Emerging evidence substantiates the potential of porous titanium alloy (pTi) as an ideal bone-graft substitute because of its excellent biocompatibility and structural properties. However, it remains a major clinical concern for promoting high-efficiency and high-quality osseointegration of pTi, which is beneficial for securing long-term implant stability. Accumulating evidence demonstrates the capacity of low-amplitude whole-body vibration (WBV) in preventing osteopenia, whereas the effects and mechanisms of WBV on osteogenesis and osseointegration of pTi remain unclear. Our present study shows that WBV enhanced cellular attachment and proliferation, and induced well-organized cytoskeleton of primary osteoblasts in pTi. WBV upregulated osteogenesis-associated gene and protein expression in primary osteoblasts, including OCN, Runx2, Wnt3a, Lrp6 and β-catenin. In vivo findings demonstrate that 6-week and 12-week WBV stimulated osseointegration, bone ingrowth and bone formation rate of pTi in rabbit femoral bone defects via μCT, histological and histomorphometric analyses. WBV induced higher ALP, OCN, Runx2, BMP2, Wnt3a, Lrp6 and β-catenin, and lower Sost and RANKL/OPG gene expression in rabbit femora. Our findings demonstrate that WBV promotes osteogenesis and osseointegration of pTi via its anabolic effect and potential anti-catabolic activity, and imply the promising potential of WBV for enhancing the repair efficiency and quality of pTi in osseous defects.
Jing, Da; Tong, Shichao; Zhai, Mingming; Li, Xiaokang; Cai, Jing; Wu, Yan; Shen, Guanghao; Zhang, Xuhui; Xu, Qiaoling; Guo, Zheng; Luo, Erping
2015-01-01
Emerging evidence substantiates the potential of porous titanium alloy (pTi) as an ideal bone-graft substitute because of its excellent biocompatibility and structural properties. However, it remains a major clinical concern for promoting high-efficiency and high-quality osseointegration of pTi, which is beneficial for securing long-term implant stability. Accumulating evidence demonstrates the capacity of low-amplitude whole-body vibration (WBV) in preventing osteopenia, whereas the effects and mechanisms of WBV on osteogenesis and osseointegration of pTi remain unclear. Our present study shows that WBV enhanced cellular attachment and proliferation, and induced well-organized cytoskeleton of primary osteoblasts in pTi. WBV upregulated osteogenesis-associated gene and protein expression in primary osteoblasts, including OCN, Runx2, Wnt3a, Lrp6 and β-catenin. In vivo findings demonstrate that 6-week and 12-week WBV stimulated osseointegration, bone ingrowth and bone formation rate of pTi in rabbit femoral bone defects via μCT, histological and histomorphometric analyses. WBV induced higher ALP, OCN, Runx2, BMP2, Wnt3a, Lrp6 and β-catenin, and lower Sost and RANKL/OPG gene expression in rabbit femora. Our findings demonstrate that WBV promotes osteogenesis and osseointegration of pTi via its anabolic effect and potential anti-catabolic activity, and imply the promising potential of WBV for enhancing the repair efficiency and quality of pTi in osseous defects. PMID:26601709
A Novel Low-Molecular-Weight Compound Enhances Ectopic Bone Formation and Fracture Repair
Wong, Eugene; Sangadala, Sreedhara; Boden, Scott D.; Yoshioka, Katsuhito; Hutton, William C.; Oliver, Colleen; Titus, Louisa
2013-01-01
Background: Use of recombinant human bone morphogenetic protein-2 (rhBMP-2) is expensive and may cause local side effects. A small synthetic molecule, SVAK-12, has recently been shown in vitro to potentiate rhBMP-2-induced transdifferentiation of myoblasts into the osteoblastic phenotype. The aims of this study were to test the ability of SVAK-12 to enhance bone formation in a rodent ectopic model and to test whether a single percutaneous injection of SVAK-12 can accelerate callus formation in a rodent femoral fracture model. Methods: Collagen disks with rhBMP-2 alone or with rhBMP-2 and SVAK-12 were implanted in a standard athymic rat chest ectopic model, and radiographic analysis was performed at four weeks. In a second set of rats (Sprague-Dawley), SVAK-12 was percutaneously injected into the site of a closed femoral fracture. The fractures were analyzed radiographically and biomechanically (with torsional testing) five weeks after surgery. Results: In the ectopic model, there was dose-dependent enhancement of rhBMP-2 activity with use of SVAK-12 at doses of 100 to 500 μg. In the fracture model, the SVAK-12-treated group had significantly higher radiographic healing scores than the untreated group (p = 0.028). Biomechanical testing revealed that the fractured femora in the 200 to 250-μg SVAK-12 group were 43% stronger (p = 0.008) and 93% stiffer (p = 0.014) than those in the control group. In summary, at five weeks the femoral fracture group injected with SVAK-12 showed significantly improved radiographic and biomechanical evidence of healing compared with the controls. Conclusions: A single local dose of a low-molecular-weight compound, SVAK-12, enhanced bone-healing in the presence of low-dose exogenous rhBMP-2 (in the ectopic model) and endogenous rhBMPs (in the femoral fracture model). Clinical Relevance: This study demonstrates that rhBMP-2 responsiveness can be enhanced by a novel small molecule, SVAK-12. Local application of anabolic small molecules has the potential for potentiating and accelerating fracture-healing. Use of this small molecule to lower required doses of rhBMPs might both decrease their cost and improve their safety profile. PMID:23467869
Ding, Ming; Andreasen, Christina M; Dencker, Mads L; Jensen, Anders E; Theilgaard, Naseem; Overgaard, Søren
2015-04-01
Cylindrical critical size defects were created at the distal femoral condyles bilaterally of eight female adult sheep. Titanium implants with 2-mm concentric gaps were inserted and the gaps were filled with one of the four materials: allograft; a synthetic 15-amino acid cell-binding peptide coated hydroxyapatite (ABM/P-15); hydroxyapatite + βtricalciumphosphate+ Poly-Lactic-Acid (HA/βTCP-PDLLA); or ABM/P-15+HA/βTCP-PDLLA. After nine weeks, bone-implant blocks were harvested and sectioned for micro-CT scanning, push-out test, and histomorphometry. Significant bone formation and implant fixation could be observed in all four groups. Interestingly, the microarchitecture of the ABM/P-15 group was significantly different from the control group. Tissue volume fraction and thickness were significantly greater in the ABM/P-15 group than in the allograft group. Bone formation and bone ingrowth to porous titanium implant were not significantly different among the four groups. The ABM/P-15 group had similar shear mechanical properties on implant fixation as the allograft group. Adding HA/βTCP-PDLLA to ABM/P-15 did not significantly change these parameters. This study revealed that ABM/P-15 had significantly bone formation in concentric gap, and its enhancements on bone formation and implant fixation were at least as good as allograft. It is suggested that ABM/P-15 might be a good alternative biomaterial for bone implant fixation in this well-validated critical-size defect gap model in sheep. Nevertheless, future clinical researches should focus on prospective, randomized, controlled trials in order to fully elucidate whether ABM/P-15 could be a feasible candidate for bone substitute material in orthopedic practices. © 2014 Wiley Periodicals, Inc.
Yamaguchi, Shoki; Aoyama, Tomoki; Ito, Akira; Nagai, Momoko; Iijima, Hirotaka; Tajino, Junichi; Zhang, Xiangkai; Kiyan, Wataru; Kuroki, Hiroshi
2016-01-01
The repair of articular cartilage is challenging owing to the restriction in the ability of articular cartilage to repair itself. Therefore, cell supplementation therapy is possible cartilage repair method. However, few studies have verified the efficacy and safety of cell supplementation therapy. The current study assessed the effect of exercise on early the phase of cartilage repair following cell supplementation utilizing mesenchymal stromal cell (MSC) intra-articular injection. An osteochondral defect was created on the femoral grooves bilaterally of Wistar rats. Mesenchymal stromal cells that were obtained from male Wistar rats were cultured in monolayer. After 4 weeks, MSCs were injected into the right knee joint and the rats were randomized into an exercise or no-exercise intervention group. The femurs were divided as follows: C group (no exercise without MSC injection); E group (exercise without MSC injection); M group (no exercise with MSC injection); and ME group (exercise with MSC injection). At 2, 4, and 8 weeks after the injection, the femurs were sectioned and histologically graded using the Wakitani cartilage repair scoring system. At 2 weeks after the injection, the total histological scores of the M and ME groups improved significantly compared with those of the C group. Four weeks after the injection, the scores of both the M and ME groups improved significantly. Additionally, the scores in the ME group showed a significant improvement compared to those in the M group. The improvement in the scores of the E, M, and ME groups at 8 weeks were not significantly different. The findings indicate that exercise may enhance cartilage repair after an MSC intra-articular injection. This study highlights the importance of exercise following cell transplantation therapy. PMID:26968036
Yamaguchi, Shoki; Aoyama, Tomoki; Ito, Akira; Nagai, Momoko; Iijima, Hirotaka; Tajino, Junichi; Zhang, Xiangkai; Kiyan, Wataru; Kuroki, Hiroshi
2016-01-01
The repair of articular cartilage is challenging owing to the restriction in the ability of articular cartilage to repair itself. Therefore, cell supplementation therapy is possible cartilage repair method. However, few studies have verified the efficacy and safety of cell supplementation therapy. The current study assessed the effect of exercise on early the phase of cartilage repair following cell supplementation utilizing mesenchymal stromal cell (MSC) intra-articular injection. An osteochondral defect was created on the femoral grooves bilaterally of Wistar rats. Mesenchymal stromal cells that were obtained from male Wistar rats were cultured in monolayer. After 4 weeks, MSCs were injected into the right knee joint and the rats were randomized into an exercise or no-exercise intervention group. The femurs were divided as follows: C group (no exercise without MSC injection); E group (exercise without MSC injection); M group (no exercise with MSC injection); and ME group (exercise with MSC injection). At 2, 4, and 8 weeks after the injection, the femurs were sectioned and histologically graded using the Wakitani cartilage repair scoring system. At 2 weeks after the injection, the total histological scores of the M and ME groups improved significantly compared with those of the C group. Four weeks after the injection, the scores of both the M and ME groups improved significantly. Additionally, the scores in the ME group showed a significant improvement compared to those in the M group. The improvement in the scores of the E, M, and ME groups at 8 weeks were not significantly different. The findings indicate that exercise may enhance cartilage repair after an MSC intra-articular injection. This study highlights the importance of exercise following cell transplantation therapy.
Zacharin, Margaret; Foster, Bruce; Donald, Geoffrey; Hassall, Timothy; Siafarikas, Aris; Johnson, Michael; Tham, Elaine; Whitewood, Colin; Gebski, Val; Cowell, Chris T; Little, David Graham; Munns, Craig Frank
2017-01-01
Introduction Perthes disease (PD) is an idiopathic disorder presenting with avascular necrosis to the femoral head, which frequently results in flattening. Long-term function is directly related to the subsequent femoral head sphericity. Current treatment includes mechanical modalities and surgical procedures, which are therapeutic but are not uniformly able to prevent collapse. The use of the nitrogen-containing bisphosphonate zoledronic acid (ZA) to inhibit osteoclastic bone resorption is aimed at preserving femoral head strength, reducing collapse and thus maintaining shape. The proposed multicentre, prospective, randomised controlled trial intends to evaluate the efficacy of ZA treatment in PD. Methods and analysis An open-label randomised control trial recruiting 100 children (50 each treatment arm) 5 to 16 years old with unilateral PD. Subjects are randomly assigned to either (a) ZA and standard care or (b) Standard care. The primary outcome measure is deformity index (DI), a radiographic parameter of femoral head roundness assessed at 24 months, following 12 months of ZA treatment (3-monthly doses of ZA 0.025 mg/kg at baseline, 3, 6, 9 and 12 months) plus 12 months observation (group A) or 24 months of observation (group B). Secondary outcome measures are femoral head subluxation, Faces Pain scale, Harris hip score and quality of life. Assessments are made at baseline, 3 monthly during the first year of follow-up and then 6 monthly, until the 24th month. Ethics and dissemination The study commenced following the written approval from the Human Research Ethics Committee. Safety considerations regarding the effects of ZA are monitored which include the subject’s symptomatology, mineral status, bone mass and turnover activity, and metaphyseal modelling. Data handling plan requires that all documents, clinical information, biological samples and investigation results will be held in strict confidence by study investigators to preserve its safety and confidentiality. Trial registration number Australian and New Zealand Clinical Trials ACTRN12610000407099, pre-results. PMID:29637122
Jenkins, Thomas; Coutts, Louise V; D'Angelo, Stefania; Dunlop, Douglas G; Oreffo, Richard O C; Cooper, Cyrus; Harvey, Nicholas C; Thurner, Phillipp J
2016-01-01
In contrast to traditional approaches to fracture risk assessment using clinical risk factors and bone mineral density (BMD), a new technique, reference point microindentation (RPI), permits direct assessment of bone quality; in vivo tibial RPI measurements appear to discriminate patients with a fragility fracture from controls. However, it is unclear how this relates to the site of the most clinically devastating fracture, the femoral neck, and whether RPI provides information complementary to that from existing assessments. Femoral neck samples were collected at surgery after low-trauma hip fracture (n = 46; 17 male; aged 83 [interquartile range 77-87] years) and compared, using RPI (Biodent Hfc), with 16 cadaveric control samples, free from bone disease (7 male; aged 65 [IQR 61-74] years). A subset of fracture patients returned for dual-energy X-ray absorptiometry (DXA) assessment (Hologic Discovery) and, for the controls, a micro-computed tomography setup (HMX, Nikon) was used to replicate DXA scans. The indentation depth was greater in femoral neck samples from osteoporotic fracture patients than controls (p < 0.001), which persisted with adjustment for age, sex, body mass index (BMI), and height (p < 0.001) but was site-dependent, being less pronounced in the inferomedial region. RPI demonstrated good discrimination between fracture and controls using receiver-operating characteristic (ROC) analyses (area under the curve [AUC] = 0.79 to 0.89), and a model combining RPI to clinical risk factors or BMD performed better than the individual components (AUC = 0.88 to 0.99). In conclusion, RPI at the femoral neck discriminated fracture cases from controls independent of BMD and traditional risk factors but dependent on location. The clinical RPI device may, therefore, supplement risk assessment and requires testing in prospective cohorts and comparison between the clinically accessible tibia and the femoral neck. © 2015 American Society for Bone and Mineral Research. © 2015 American Society for Bone and Mineral Research.
Genomic expression analysis of rat chromosome 4 for skeletal traits at femoral neck.
Alam, Imranul; Sun, Qiwei; Liu, Lixiang; Koller, Daniel L; Liu, Yunlong; Edenberg, Howard J; Econs, Michael J; Foroud, Tatiana; Turner, Charles H
2008-10-08
Hip fracture is the most devastating osteoporotic fracture type with significant morbidity and mortality. Several studies in humans and animal models identified chromosomal regions linked to hip size and bone mass. Previously, we identified that the region of 4q21-q41 on rat chromosome (Chr) 4 harbors multiple femoral neck quantitative trait loci (QTLs) in inbred Fischer 344 (F344) and Lewis (LEW) rats. The purpose of this study is to identify the candidate genes for femoral neck structure and density by correlating gene expression in the proximal femur with the femoral neck phenotypes linked to the QTLs on Chr 4. RNA was extracted from proximal femora of 4-wk-old rats from F344 and LEW strains, and two other strains, Copenhagen 2331 and Dark Agouti, were used as a negative control. Microarray analysis was performed using Affymetrix Rat Genome 230 2.0 arrays. A total of 99 genes in the 4q21-q41 region were differentially expressed (P < 0.05) among all strains of rats with a false discovery rate <10%. These 99 genes were then ranked based on the strength of correlation between femoral neck phenotypes measured in F2 animals, homozygous for a particular strain's allele at the Chr 4 QTL and the expression level of the gene in that strain. A total of 18 candidate genes were strongly correlated (r(2) > 0.50) with femoral neck width and prioritized for further analysis. Quantitative PCR analysis confirmed 14 of 18 of the candidate genes. Ingenuity pathway analysis revealed several direct or indirect relationships among the candidate genes related to angiogenesis (VEGF), bone growth (FGF2), bone formation (IGF2 and IGF2BP3), and resorption (TNF). This study provides a shortened list of genetic determinants of skeletal traits at the hip and may lead to novel approaches for prevention and treatment of hip fracture.
Genomic expression analysis of rat chromosome 4 for skeletal traits at femoral neck
Alam, Imranul; Sun, Qiwei; Liu, Lixiang; Koller, Daniel L.; Liu, Yunlong; Edenberg, Howard J.; Econs, Michael J.; Foroud, Tatiana; Turner, Charles H.
2008-01-01
Hip fracture is the most devastating osteoporotic fracture type with significant morbidity and mortality. Several studies in humans and animal models identified chromosomal regions linked to hip size and bone mass. Previously, we identified that the region of 4q21-q41 on rat chromosome (Chr) 4 harbors multiple femoral neck quantitative trait loci (QTLs) in inbred Fischer 344 (F344) and Lewis (LEW) rats. The purpose of this study is to identify the candidate genes for femoral neck structure and density by correlating gene expression in the proximal femur with the femoral neck phenotypes linked to the QTLs on Chr 4. RNA was extracted from proximal femora of 4-wk-old rats from F344 and LEW strains, and two other strains, Copenhagen 2331 and Dark Agouti, were used as a negative control. Microarray analysis was performed using Affymetrix Rat Genome 230 2.0 arrays. A total of 99 genes in the 4q21-q41 region were differentially expressed (P < 0.05) among all strains of rats with a false discovery rate <10%. These 99 genes were then ranked based on the strength of correlation between femoral neck phenotypes measured in F2 animals, homozygous for a particular strain's allele at the Chr 4 QTL and the expression level of the gene in that strain. A total of 18 candidate genes were strongly correlated (r2 > 0.50) with femoral neck width and prioritized for further analysis. Quantitative PCR analysis confirmed 14 of 18 of the candidate genes. Ingenuity pathway analysis revealed several direct or indirect relationships among the candidate genes related to angiogenesis (VEGF), bone growth (FGF2), bone formation (IGF2 and IGF2BP3), and resorption (TNF). This study provides a shortened list of genetic determinants of skeletal traits at the hip and may lead to novel approaches for prevention and treatment of hip fracture. PMID:18728226
Wang, Xiaona; Ye, Ping; Cao, Ruihua; Yang, Xu; Xiao, Wenkai; Zhang, Yun; Bai, Yongyi; Wu, Hongmei
2016-05-18
Epidemiological studies have disclosed an independent effect of triglycerides on coronary heart disease despite achievement of low-density lipoprotein cholesterol goals with statin therapy. Arterial stiffness has been increasingly recognized as a strong predictor of cardiovascular disease and atherosclerotic disease. The association between triglycerides and arterial stiffness is not well characterized. We aimed to determine the relationship between triglycerides and arterial stiffness in a community-based longitudinal sample from Beijing, China. We related levels of plasma TGs to measures of arterial stiffness (carotid-femoral pulse wave velocity [PWV] and carotid-radial PWV) in 1447 subjects (mean age, 61.3 years) from a community-based population in Beijing, China. After a median follow-up interval of 4.8 years, multiple linear regression analysis revealed that TGs were independently associated with carotid-femoral PWV (β = 0.747, P < 0.001) and carotid-radial PWV (β = 0.367, P = 0.001). In the group older than 65 years, the association between baseline TG levels and follow-up carotid-femoral PWV (β = 1.094, P = 0.001) and carotid-radial PWV (β = 0.524, P = 0.002) were strengthened. In forward stepwise multivariate logistic regression analysis, every SD increase in TGδ was associated with a 1.296-increased likelihood of the presence of carotid-femoral PWVδII (OR [per SD increase in TGδ]: 1.296; 95% CI: 1.064 ~ 1.580; P = 0.010) in Model 2, whereas the relationship between TGδ and carotid-radial PWVδII disappeared. In addition, the relationship was strengthened between TGδ and the presence of carotid-femoral PWVδII (OR 1.526, 95% CI: 1.088-2.141, P = 0.014) in the group older than 65 years but not carotid-radial PWVδII. No association was noted in subjects younger than 65 years. Lower triglyceride levels were significantly associated with decreases in carotid-femoral PWV, indicating that achieving low TG levels may be an additional therapeutic consideration in subjects with atherosclerotic disease.
Inoue, Hiroaki; Atsumi, Satoru; Ichimaru, Shohei; Fujiwara, Hiroyoshi; Kubo, Toshikazu
2014-01-01
Complications of patellar dislocation include osteochondral injury of the lateral femoral condyle and patella. Most cases of osteochondral injury occur in the anterior region, which is the non-weight-bearing portion of the lateral femoral condyle. We describe two patients with osteochondral injury of the weight-bearing surface of the lateral femoral condyle associated with lateral dislocation of the patella. The patients were 18- and 11-year-old females. Osteochondral injury occurred on the weight-bearing surface distal to the lateral femoral condyle. The presence of a free osteochondral fragment and osteochondral injury of the lateral femoral condyle was confirmed on MRI and reconstruction CT scan. Treatment consisted of osteochondral fragment fixation or microfracture, as well as patellar stabilization. Osteochondral injury was present in the weight-bearing portion of the lateral femoral condyle in both patients, suggesting that the injury was caused by friction between the patella and lateral femoral condyle when the patella was dislocated or reduced at about 90° flexion of the knee joint. These findings indicate that patellar dislocation may occur and osteochondral injury may extend to the weight-bearing portion of the femur even in deep flexion, when the patella is stabilized on the bones of the femoral groove. PMID:25506015
Stone, Jonathan; Matchett, Gerald
2014-01-01
Management of pain from skeletal metastases is notoriously difficult. Case reports and case series have described radiofrequency ablation of the obturator nerve branches to the femoral head for treatment of intractable hip pain. Ablation of the obturator branches to the femoral head is technically difficult because of bony and vascular anatomy, including close proximity of the femoral vessels. Here we present the case of a 79-year-old woman with intractable right hip pain and inability to ambulate secondary to metastatic non-small cell lung cancer in the femoral head and acetabulum, treated with thermal radiofrequency ablation of the obturator and femoral nerve branches to the femoral head. Ablation of the obturator nerve was done via anterior placement of the radiofrequency needle under combined ultrasound and fluoroscopic guidance, passing the radiofrequency needle between the femoral artery and femoral vein. Real-time ultrasound guidance was used to avoid vascular puncture. Thermal radiofrequency ablation resulted in sustained pain relief, and resumption in the ability of the patient to ambulate. From this case we suggest that an anterior approach to the obturator nerve branches to the femoral head may be technically feasible using combined ultrasound and fluoroscopic guidance to avoid vascular puncture.
Bălan, Mirela; Kiefer, Friedemann
2015-01-01
Creating a model for intravital visualization of femoral bone marrow, a major site of hematopoiesis in adult mammalian organisms, poses a serious challenge, in that it needs to overcome bone opacity and the inaccessibility of marrow. Furthermore, meaningful analysis of bone marrow developmental and differentiation processes requires the repetitive observation of the same site over long periods of time, which we refer to as chronic imaging. To surmount these issues, we developed a chronic intravital imaging model that allows the observation of split femurs, ectopically transplanted into a dorsal skinfold chamber of a host mouse. Repeated, long term observations are facilitated by multiphoton microscopy, an imaging technique that combines superior imaging capacity at greater tissue depth with low phototoxicity. The transplanted, ectopic femur was stabilized by its sterile environment and rapidly connected to the host vasculature, allowing further development and observation of extended processes. After optimizing transplant age and grafting procedure, we observed the development of new woven bone and maturation of secondary ossification centers in the transplanted femurs, preceded by the sprouting of a sinusoidal-like vascular network, which was almost entirely composed of femoral endothelial cells. After two weeks, the transplant was still populated with stromal and haematopoietic cells belonging both to donor and host. Over this time frame, the transplant partially retained myeloid progenitor cells with single and multi-lineage differentiation capacity. In summary, our model allowed repeated intravital imaging of bone marrow angiogenesis and hematopoiesis. It represents a promising starting point for the development of improved chronic optical imaging models for femoral bone marrow. PMID:28243515
Petit, Yvan; Cloutier, Luc P; Duke, Kajsa; Laflamme, G Yves
2012-04-01
Greater trochanter (GT) stabilization techniques following a fracture or an osteotomy are still showing high levels of postoperative complications. Understanding the effect of femoral neck cut placement, cable tension and muscles forces on GT fragment displacements could help surgeons optimize their techniques. A 3D finite element model has been developed to evaluate, through a statistical experimental design, the impact of the above variables on the GT fragment gap and sliding displacements. Muscles forces were simulating typical daily activities. Stresses were also investigated. The femoral neck cut placement had the most significant effect on the fragment displacement. Lowering it by 5 mm increased the gap and sliding fragment displacements by 288 and 128 %, respectively. Excessive cable tightening provided no significant reduction in fragment displacement. Muscle activities increased the gap and the sliding displacements for all muscle configurations. The maximum total displacement of 0.41 mm was present with a 10 mm femoral neck cut, a cable tension of 178 N, and stair climbing. Caution must be used not to over tighten the cables as the potential damage caused by the increased stress is more significant than any reduction in fragment displacement. Furthermore, preservation of the contact area is important for GT stabilization.
Wegrzyn, Julien; Roux, Jean-Paul; Loriau, Charlotte; Bonin, Nicolas; Pibarot, Vincent
2018-02-22
Using a cementless femoral stem in total hip arthroplasty (THA), optimal filling of the proximal femoral metaphyseal volume (PFMV) and restoration of the extramedullary proximal femoral (PF) parameters (i.e., femoral offset (FO), neck length (FNL), and head height (FHH)) constitute key goals for optimal hip biomechanics, functional outcome, and THA survivorship. However, almost 30% of mismatch between the PF anatomy and implant geometry of the most widely implanted non-modular cementless femoral stem has been demonstrated in a computed tomography scan (CT scan) study. Therefore, this anatomic study aimed to evaluate the relationship between the intra- and extramedullary PF parameters using tridimensional CT scan reconstructions. One hundred fifty-one CT scans of adult healthy hips were obtained from 151 male Caucasian patients (mean age = 66 ± 11 years) undergoing lower limb CT scan arteriography. Tridimensional PF reconstructions and parameter measurements were performed using a corrected PF coronal plane-defined by the femoral neck and diaphyseal canal longitudinal axes-to avoid influence of PF helitorsion and femoral neck version on extramedullary PF parameters. Independently of the femoral neck-shaft angle, the PFMV was significantly and positively correlated with the FO, FNL, and FHH (r = 0.407 to 0.420; p < 0.0001). This study emphasized that the tridimensional PF geometry measurement in the corrected coronal plane of the femoral neck can be useful to determine and optimize the design of a non-modular cementless femoral stem. Particularly, continuous homothetic size progression of the intra- and extramedullary PF parameters should be achieved to assure stem fixation and restore anatomic hip biomechanics.
Steinbrück, Arnd; Schröder, Christian; Woiczinski, Matthias; Schmidutz, Florian; Müller, Peter E; Jansson, Volkmar; Fottner, Andreas
2017-11-01
Increased retropatellar pressure and altered kinematics are associated with anterior knee pain and unsatisfied patients after total knee arthroplasty (TKA). Since malposition of the implant is believed to contribute to postoperative pain, we performed this in vitro study to evaluate the influence of mediolateral femoral component position on retropatellar pressure as well as tibio-femoral and patella kinematics. For the test, a fixed-bearing TKA was implanted in eight fresh frozen cadaver specimens. To determine the impact of mediolateral (ML) position, three variants of femoral components (3-mm medialization, neutral position and 3-mm lateralization) were produced using rapid prototyping replicas. In a knee rig, a loaded squat from 20° to 120° of flexion was applied. Retropatellar pressure distribution was measured with a pressure-sensitive film. Additionally, an ultrasonic-based three-dimensional motion analysis system was used to register patello- and tibio-femoral kinematics. ML translation of the femoral component by 3 mm did not lead to a significant alteration in retropatellar peak pressure (medial 6.5 ± 2.5 MPa vs. lateral 6.0 ± 2.4 MPa). Following the ML translation of the femoral component, the patella was significantly shifted and tilted in the same directions. Varying the ML femoral component position also led to a significant alteration in femoral roll-back. In day-by-day use, ML position should be chosen with care since there is a significant influence on patella shift and femoral roll-back. Retropatellar pressure is not significantly altered, so there is no clear evidence of an impact on anterior knee pain.
Dumbre Patil, Sampat S; Karkamkar, Sachin S; Patil, Vaishali S Dumbre; Patil, Shailesh S; Ranaware, Abhijeet S
2016-01-01
When primary fixation of proximal femoral fractures with implants fails, revision osteosynthesis may be challenging. Tracts of previous implants and remaining insufficient bone stock in the proximal femur pose unique problems for the treatment. Intramedullary implants like proximal femoral nail (PFN) or surface implants like Dynamic Condylar Screw (DCS) are few of the described implants for revision surgery. There is no evidence in the literature to choose one implant over the other. We used the reverse distal femur locking compression plate (LCP) of the contralateral side in such cases undergoing revision surgery. This implant has multiple options of fixation in proximal femur and its curvature along the length matches the anterior bow of the femur. We aimed to evaluate the efficacy of this implant in salvage situations. Twenty patients of failed primary proximal femoral fractures who underwent revision surgery with reverse distal femoral locking plate from February 2009 to November 2012 were included in this retrospective study. There were 18 subtrochanteric fractures and two ipsilateral femoral neck and shaft fractures, which exhibited delayed union or nonunion. The study included 14 males and six females. The mean patient age was 43.6 years (range 22-65 years) and mean followup period was 52.1 months (range 27-72 months). Delayed union was considered when clinical and radiological signs of union failed to progress at the end of four months from initial surgery. All fractures exhibited union without any complications. Union was assessed clinically and radiologically. One case of ipsilateral femoral neck and shaft fracture required bone grafting at the second stage for delayed union of the femoral shaft fracture. Reverse distal femoral LCP of the contralateral side can be used as a salvage option for failed fixation of proximal femoral fractures exhibiting nonunion.
[Correlation analysis on the disorders of patella-femoral joint and torsional deformity of tibia].
Sun, Zhen-Jie; Yuan, Yi; Liu, Rui-Bo
2015-03-01
To reveal the possible mechanism involved in patella-femoral degenerative arthritis (PFDA) in- duced by torsion-deformity of tibia via analyzing the relationship between torsion-deformity of the tibia in patients with PFDA and the disorder of patella-femoral joint under the static and dynamic conditions. From October 2009 to October 2010, 50 patients (86 knees, 24 knees of male patients and 62 knees of female patients) with PFDA were classified as disease group and 16 people (23 knees, 7 knees of males and 16 knees of females) in the control group. The follow indexes were measured: the torsion-angle of tibia on CT scanning imagings, the patella-femoral congruence angle and lateral patella-femoral angle under static and dynamic conditions when the knee bent at 30 degrees of flexion. Based on the measurement results, the relationship between the torsion-deformity of tibias and the disorders of patella-femoral joints in patients with PFDA were analyzed. Finally,the patients were divided into three groups including large torsion-angle group, small torsion-angle group and normal group according to the size of torsion-angle, in order to analyze the relationship between torsion-deformity and disorders of patella-femoral joint, especially under the dynamic conditions. Compared with patients without PFDA, the ones with PFDA had bigger torsion-angle (30.30 ± 7.11)° of tibia, larger patella-femoral congruence angle (13.20 ± 3.94)° and smaller lateral patella-femoral angle (12.30 ± 3.04)°. The congruence angle and lateral patella-femoral angle under static and dynamic conditions had statistical differences respectively in both too-big torsion-angle group and too-small torsion-angle group. The congruence angle and lateral patella-femoral angle under static and dynamic conditions had no statistical differences in normal torsion-angle group. Torsion-deformity of tibia is the main reason for disorder of patella-femoral joint in the patients with PFDA. Torsion-deformity of tibia is always accompanied by instability of patella-femoral joint,especially under the dynamic condition, thus causing PFDA. It can not only provide arrangement information and degenerative condition of patella-femoral joint,but also provide guidance through the analysis on the relationship for better clinical prevention and early treatment of degenerative bone and joint disease.
Objectively measured physical activity and bone strength in 9-year-old boys and girls.
Sardinha, Luís B; Baptista, Fátima; Ekelund, Ulf
2008-09-01
The purpose of this work was to analyze the relationship between intensity and duration of physical activity and composite indices of femoral neck strength and bone-mineral content of the femoral neck, lumbar spine, and total body. Physical activity was assessed by accelerometry in 143 girls and 150 boys (mean age: 9.7 years). Measurement of bone-mineral content, femoral neck bone-mineral density, femoral neck width, hip axis length, and total body fat-free mass was performed with dual-energy radiograph absorptiometry. Compressive [(bone-mineral density x femoral neck width/weight)] and bending strength [(bone-mineral density x femoral neck width(2))/(hip axis length x weight)] express the forces that the femoral neck has to withstand in weight bearing, whereas impact strength [(bone-mineral density x femoral neck width x hip axis length)/(height x weight)] expresses the energy that the femoral neck has to absorb in an impact from standing height. Analysis of covariance (fat-free mass and age adjusted) showed differences between boys and girls of approximately 9% for compressive, 10% for bending, and 9% for impact strength. Stepwise regression analysis using time spent at sedentary, light, moderate, and vigorous physical activity as predictors revealed that vigorous physical activity explained 5% to 9% of femoral neck strength variable variance in both genders, except for bending strength in boys, and approximately 1% to 3% of total body and femoral neck bone-mineral content variance. Vigorous physical activity was then used to categorize boys and girls into quartiles. Pairwise comparison indicated that boys in the third and fourth quartiles (accumulation of >26 minutes/day) demonstrated higher compressive (11%-12%), bending (10%), and impact (14%) strength than boys in the first quartile. In girls, comparison revealed a difference between the fourth (accumulation of >25 minutes/day) and first quartiles for bending strength (11%). We did not observe any relationship between physical activity and lumbar spine strength. Femoral neck strength is higher in boys than girls. Vigorous intensity emerged as the main physical activity predictor of femoral neck strength but did not explain gender differences. Daily vigorous physical activity for at least approximately 25 minutes seems to improve femoral neck bone health in children.
Grau, Luis; Collon, Kevin; Alhandi, Ali; Kaimrajh, David; Varon, Maria; Latta, Loren; Vilella, Fernando
2018-06-01
The aim of this study is to evaluate the biomechanical effect of filling locking variable angle (VA) screw holes at the area of metaphyseal fracture comminution in a Sawbones® (Sawbones USA, Vashon, Washington) model (AO/OTA 33A-3 fracture) using a Synthes VA locking compression plate (LCP) (Depuy Synthes, Warsaw, Indiana). Seven Sawbones® femur models had a Synthes VA-LCP placed as indicated by the manufacturers technique. A 4cm osteotomy was then created to simulate an AO/OTA 33-A3 femoral fracture pattern with metaphyseal comminution. The control group consisted of four constructs in which the open screw holes at the area of comminution were left unfilled; the experimental group consisted of three constructs in which the VA screw holes were filled with locking screws. One of the control constructs was statically loaded to failure at a rate of 5mm/min. A value equal to 75% of the ultimate load to failure was used as the loading force for fatigue testing of 250,000 cycles at 3Hz. Cycles to failure was recorded for each construct and averages were compared between groups. The average number of cycles to failure in the control and experimental groups were 37524±8187 and 43304±23835, respectively (p=0.72). No significant difference was observed with respect to cycles to failure or mechanism of failure between groups. In all constructs in both the control and experimental groups, plate failure reproducibly occurred with cracks through the variable angle holes in the area of bridged comminution. The Synthes VA-LCP in a simulated AO/OTA 33-A3 comminuted metaphyseal femoral fracture fails in a reproducible manner at the area of comminution through the "honeycomb" VA screw holes. Filling open VA screw holes at the site of comminution with locking screws does not increase fatigue life of the Synthes VA-LCP in a simulated AO/OTA 33-A3 distal femoral fracture. Further studies are necessary to determine whether use of this particular plate is contraindicated when bridging distal femoral fractures with metaphyseal comminution.
Lichstein, Paul M; Kleimeyer, John P; Githens, Michael; Vorhies, John S; Gardner, Michael J; Bellino, Michael; Bishop, Julius
2018-07-01
A well-reduced femoral neck fracture is more likely to heal than a poorly reduced one, and increasing the quality of the surgical exposure makes it easier to achieve anatomic fracture reduction. Two open approaches are in common use for femoral neck fractures, the modified Smith-Petersen and Watson-Jones; however, to our knowledge, the quality of exposure of the femoral neck exposure provided by each approach has not been investigated. (1) What is the respective area of exposed femoral neck afforded by the Watson-Jones and modified Smith-Petersen approaches? (2) Is there a difference in the ability to visualize and/or palpate important anatomic landmarks provided by the Watson-Jones and modified Smith-Petersen approaches? Ten fresh-frozen human pelvi underwent both modified Smith-Petersen (utilizing the caudal extent of the standard Smith-Petersen interval distal to the anterosuperior iliac spine and parallel to the palpable interval between the tensor fascia lata and the sartorius) and Watson-Jones approaches. Dissections were performed by three fellowship-trained orthopaedic traumatologists with extensive experience in both approaches. Exposure (in cm) was quantified with calibrated digital photographs and specialized software. Modified Smith-Petersen approaches were analyzed before and after rectus femoris tenotomy. The ability to visualize and palpate seven clinically relevant anatomic structures (the labrum, femoral head, subcapital femoral neck, basicervical femoral neck, greater trochanter, lesser trochanter, and medial femoral neck) was also recorded. The quantified area of the exposed proximal femur was utilized to compare which approach afforded the largest field of view of the femoral neck and articular surface for assessment of femoral neck fracture and associated femoral head injury. The ability to visualize and palpate surrounding structures was assessed so that we could better understand which approach afforded the ability to assess structures that are relevant to femoral neck fracture reduction and fixation. After controlling for age, body mass index, height, and sex, we found the modified Smith-Petersen approach provided a mean of 2.36 cm (95% confidence interval [CI], 0.45-4.28 cm; p = 0.015) additional exposure without rectus femoris tenotomy (p = 0.015) and 3.33 cm (95% CI, 1.42-5.24 cm; p = 0.001) additional exposure with a tenotomy compared with the Watson-Jones approach. The labrum, femoral head, subcapital femoral neck, basicervical femoral neck, and greater trochanter were reliably visible and palpable in both approaches. The lesser trochanter was palpable in all of the modified Smith-Petersen and none of the Watson-Jones approaches (p < 0.001). All modified Smith-Petersen approaches (10 of 10) provided visualization and palpation of the medial femoral neck, whereas visualization of the medial femoral neck was only possible in one of 10 Watson-Jones approaches (p < 0.001) and palpation was possible in eight of 10 Watson-Jones versus all 10 modified Smith-Petersen approaches (p = 0.470). In the hands of surgeons experienced with both surgical approaches to the femoral neck, the modified Smith-Petersen approach, with or without rectus femoris tenotomy, provides superior exposure of the femoral neck and articular surface as well as visualization and palpation of clinically relevant proximal femoral anatomic landmarks compared with the Watson-Jones approach. Open reduction and internal fixation of a femoral neck fracture is typically performed in a young patient (< 60 years old) with the objective of obtaining anatomic reduction that would not be possible by closed manipulation, thus enhancing healing potential. In the hands of surgeons experienced in both approaches, the modified Smith-Petersen approach offers improved direct access for reduction and fixation. Higher quality reductions and fixation are expected to translate to improved healing potential and outcomes. Although our experimental results are promising, further clinical studies are needed to verify if this larger exposure area imparts increased quality of reduction, healing, and improved outcomes compared with other approaches. The learning curve for the exposure is unclear, but the approach has broad applications and is frequently used in other subspecialties such as for direct anterior THA and pediatric septic hip drainage. Surgeons treating femoral neck fractures with open reduction and fixation should familiarize themselves with the modified Smith-Petersen approach.
21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metal/polymer... § 888.3390 Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis is a two-part...
Huang, Zan; Li, Yanlin; Hu, Meng; Li, Jian; You, Zhimin; Wang, Guoliang; He, Chuan
2015-02-01
To study the difference of femoral condylar twist angle (CTA) measurement in three dimensional (3-D) reconstruction digital models of human knee joint based on the two dimensional (2-D) images of MRI and CT so as to provide a reference for selecting the best method of CTA measurement in preoperative design for the femoral prosthesis rotational position. The CTA of 10 human cadaveric knee joint was measured in 3-D digital models based on MRI (group A), in 3-D digital models based on CT (group B), in the cadaveric knee joint with cartilage (group C), and in the cadaveric knee joint without cartilage (group D), respectively. The statistical analysis of the differences was made among the measurements of the CTA. The CTA values measured in 3-D digital models were (6.43 ± 0.53) degrees in group A and (3.31 ± 1.07) degrees in group B, showing significant difference (t = 10.235, P = 0.000). The CTA values measured in the cadaveric knee joint were (5.21 ± 1.28) degrees in group C and (3.33 ± 1.12) degrees in group D, showing significant difference (t = 5.770, P = 0.000). There was significant difference in the CTA values between group B and group C (t = 5.779, P = 0.000), but no significant difference was found between group A and group C (t = 3.219, P = 0.110). The CTA values measured in the 3-D digital models based on MRI are closer to the actual values measured in the knee joint with cartilage, and benefit for preoperative plan.
Simulation of Anterior Cruciate Ligament Deficiency in a Musculoskeletal Model with Anatomical Knees
Guess, Trent M; Stylianou, Antonis
2012-01-01
Abnormal knee kinematics and meniscus injury resulting from anterior cruciate ligament (ACL) deficiency are often implicated in joint degeneration even though changes in tibio-femoral contact location after injury are small, typically only a few millimeters. Ligament reconstruction surgery does not significantly reduce the incidence of early onset osteoarthritis. Increased knowledge of knee contact mechanics would increase our understanding of the effects of ACL injury and help guide ACL reconstruction methods. Presented here is a cadaver specific computational knee model combined with a body-level musculoskeletal model from a subject of similar height and weight as the cadaver donor. The knee model was developed in the multi-body framework and includes representation of the menisci. Experimental body-level measurements provided input to the musculoskeletal model. The location of tibio-menisco-femoral contact as well as contact pressures were compared for models with an intact ACL, partial ACL transection (posterolateral bundle transection), and full ACL transection during a muscle driven forward dynamics simulation of a dual limb squat. During the squat, small changes in femur motion relative to the tibia for both partial and full ACL transection push the lateral meniscus in the posterior direction at extension. The central-anterior region of the lateral meniscus then becomes “wedged” between the tibia and femur during knee flexion. This “wedging” effect does not occur for the intact knee. Peak contact pressure and contact locations are similar for the partial tear and complete ACL transection during the deep flexion portion of the squat, particularly on the lateral side. The tibio-femoral contact location on the tibia plateau shifts slightly to the posterior and lateral direction with ACL transection. PMID:22470411
Bragdon, Charles R; Malchau, Henrik; Yuan, Xunhua; Perinchief, Rebecca; Kärrholm, Johan; Börlin, Niclas; Estok, Daniel M; Harris, William H
2002-07-01
The purpose of this study was to develop and test a phantom model based on actual total hip replacement (THR) components to simulate the true penetration of the femoral head resulting from polyethylene wear. This model was used to study both the accuracy and the precision of radiostereometric analysis, RSA, in measuring wear. We also used this model to evaluate optimum tantalum bead configuration for this particular cup design when used in a clinical setting. A physical model of a total hip replacement (a phantom) was constructed which could simulate progressive, three-dimensional (3-D) penetration of the femoral head into the polyethylene component of a THR. Using a coordinate measuring machine (CMM) the positioning of the femoral head using the phantom was measured to be accurate to within 7 microm. The accuracy and precision of an RSA analysis system was determined from five repeat examinations of the phantom using various experimental set-ups of the phantom. The accuracy of the radiostereometric analysis, in this optimal experimental set-up studied was 33 microm for the medial direction, 22 microm for the superior direction, 86 microm for the posterior direction and 55 microm for the resultant 3-D vector length. The corresponding precision at the 95% confidence interval of the test results for repositioning the phantom five times, measured 8.4 microm for the medial direction, 5.5 microm for the superior direction, 16.0 microm for the posterior direction, and 13.5 microm for the resultant 3-D vector length. This in vitro model is proposed as a useful tool for developing a standard for the evaluation of radiostereometric and other radiographic methods used to measure in vivo wear.
Yang, Shuman; Luo, Yunhua; Yang, Lang; Dall'Ara, Enrico; Eastell, Richard; Goertzen, Andrew L; McCloskey, Eugene V; Leslie, William D; Lix, Lisa M
2018-05-01
Dual-energy X-ray absorptiometry (DXA)-based finite element analysis (FEA) has been studied for assessment of hip fracture risk. Femoral strength (FS) is the maximum force that the femur can sustain before its weakest region reaches the yielding limit. Fracture risk index (FRI), which also considers subject-specific impact force, is defined as the ratio of von Mises stress induced by a sideways fall to the bone yield stress over the proximal femur. We compared risk stratification for prior hip fracture using FS and FRI derived from DXA-based FEA. The study cohort included women aged ≥65years undergoing baseline hip DXA, with femoral neck T-scores <-1 and no osteoporosis treatment; 324 cases had prior hip fracture and 655 controls had no prior fracture. Using anonymized DXA hip scans, we measured FS and FRI. Separate multivariable logistic regression models were used to estimate odds ratios (ORs), c-statistics and their 95% confidence intervals (95% CIs) for the association of hip fracture with FS and FRI. Increased hip fracture risk was associated with lower FS (OR per SD 1.36, 95% CI: 1.15, 1.62) and higher FRI (OR per SD 1.99, 95% CI: 1.63, 2.43) after adjusting for Fracture Risk Assessment Tool (FRAX) hip fracture probability computed with bone mineral density (BMD). The c-statistic for the model containing FS (0.69; 95% CI: 0.65, 0.72) was lower than the c-statistic for the model with FRI (0.77; 95% CI: 0.74, 0.80) or femoral neck BMD (0.74; 95% CI: 0.71, 0.77; all P<0.05). FS and FRI were independently associated with hip fracture, but there were differences in performance characteristics. Copyright © 2018 Elsevier Inc. All rights reserved.
Effects of posture on shear rates in human brachial and superficial femoral arteries
Newcomer, S. C.; Sauder, C. L.; Kuipers, N. T.; Laughlin, M. H.; Ray, C. A.
2012-01-01
Shear rate is significantly lower in the superficial femoral compared with the brachial artery in the supine posture. The relative shear rates in these arteries of subjects in the upright posture (seated and/or standing) are unknown. The purpose of this investigation was to test the hypothesis that upright posture (seated and/or standing) would produce greater shear rates in the superficial femoral compared with the brachial artery. To test this hypothesis, Doppler ultrasound was used to measure mean blood velocity (MBV) and diameter in the brachial and superficial femoral arteries of 21 healthy subjects after being in the supine, seated, and standing postures for 10 min. MBV was significantly higher in the brachial compared with the superficial femoral artery during upright postures. Superficial femoral artery diameter was significantly larger than brachial artery diameter. However, posture had no significant effect on either brachial or superficial femoral artery diameter. The calculated shear rate was significantly greater in the brachial (73 ± 5, 91 ± 11, and 97 ± 13 s−1) compared with the superficial femoral (53 ± 4, 39 ± 77, and 44 ± 5 s−1) artery in the supine, seated, and standing postures, respectively. Contrary to our hypothesis, our current findings indicate that mean shear rate is lower in the superficial femoral compared with the brachial artery in the supine, seated, and standing postures. These findings of lower shear rates in the superficial femoral artery may be one mechanism for the higher propensity for atherosclerosis in the arteries of the leg than of the arm. PMID:18245564
Narouze, Samer N; Zakari, Adel; Vydyanathan, Amaresh
2009-01-01
Femoral nerve injury is a rare complication of cardiac catheterization and is usually caused by direct trauma during femoral artery access, compression from a hematoma, or prolonged digital pressure for post-procedural hemostasis. Peripheral nerve stimulation has been used to treat different pain syndromes in the upper and lower extremities with variable success and it typically requires direct vision with open surgical approach. Since the femoral nerve can be readily seen with ultrasonography, an ultrasound-guided lead placement seemed practical. A 61-year-old morbidly obese male who sustained femoral nerve injury during cardiac catheterization continued to complain of intractable femoral neuropathy 18 months afterwords. He failed multiple treatment modalities and continued to complain of severe neuropathic pains that markedly interfere with his daily activities. Two percutaneous leads were placed under real-time ultrasonography and the placement was confirmed with fluoroscopy. One lead was placed along the longitudinal axis of the nerve and the patient had good coverage over the anterior thigh but not below the knee. So another lead was placed horizontally across the femoral nerve in order to stimulate all the branches and the patient reported good coverage along the saphenous nerve distribution down to the foot. The patient continues to be pain free 20 months after the implant. Here we described a novel non-invasive percutaneous approach for femoral nerve stimulation with ultrasound guidance which allowed precise placement of the stimulating lead very close to the femoral nerve without the need for surgical exploration.
Reduced head-neck offset in nontraumatic osteonecrosis of the femoral head.
Fraitzl, Christian R; Kappe, Thomas; Brugger, Annina; Billich, Christian; Reichel, Heiko
2013-08-01
Risk factors for nontraumatic osteonecrosis of the femoral head have in common that they trigger intravascular coagulation and thus lead to devascularization of the femoral head. In part of the patients, however, no risk factors seem to be evident. Mechanical reasons contributing to nontraumatic osteonecrosis have not been discussed so far. We hypothesized that recurrent traumatization of the vessels supplying the femoral head by a cam-type mechanism as in femoroacetabular impingement could add to intravascular coagulation. We, therefore, asked whether structural abnormalities at the femoral head-neck junction indicative of such a mechanism could be observed in radiographs of patients with osteonecrosis of the femoral head. The preoperative anteroposterior and lateral radiographs of 77 patients who underwent surgery because of osteonecrosis of the femoral head were retrospectively screened for a reduced head-neck offset by measuring the α-angle. For comparison, the α-angle was measured on anteroposterior and lateral radiographs of 339 control subjects without evident underlying hip pathology. The mean α-angle was 62.8° (SD 18.7°) for anteroposterior and 67.6° (SD 13.2°) for lateral radiographs in patients with nontraumatic osteonecrosis of the femoral head, whereas in control subjects, the mean α-angle was 47.2° (SD 9.6°) (p < 0.0001) and 47.6° (SD 10.3°) (p < 0.0001), respectively. A reduced head-neck offset in patients with nontraumatic osteonecrosis of the femoral head may act as a mechanical (co-)factor in developing osteonecrosis of the femoral head.
Influence of Femoral Component Design on Retrograde Femoral Nail Starting Point.
Service, Benjamin C; Kang, William; Turnbull, Nathan; Langford, Joshua; Haidukewych, George; Koval, Kenneth J
2015-10-01
Our experience with retrograde femoral nailing after periprosthetic distal femur fractures was that femoral components with deep trochlear grooves posteriorly displace the nail entry point resulting in recurvatum deformity. This study evaluated the influence of distal femoral prosthetic design on the starting point. One hundred lateral knee images were examined. The distal edge of Blumensaat's line was used to create a ratio of its location compared with the maximum anteroposterior condylar width called the starting point ratio (SPR). Femoral trials from 6 manufacturers were analyzed to determine the location of simulated nail position in the sagittal plane compared with the maximum anteroposterior prosthetic width. These measurements were used to create a ratio, the femoral component ratio (FCR). The FCR was compared with the SPR to determine if a femoral component would be at risk for retrograde nail starting point posterior to the Blumensaat's line. The mean SPR was 0.392 ± 0.03, and the mean FCR was 0.416 ± 0.05, which was significantly greater (P = 0.003). The mean FCR was 0.444 ± 0.06 for the cruciate retaining (CR) trials and was 0.393 ± 0.04 for the posterior stabilized trials; this difference was significant (P < 0.001). The FCR for the femoral trials studied was significantly greater than the SPR for native knees and was significantly greater for CR femoral components compared with posterior stabilized components. These findings demonstrate that many total knee prostheses, particularly CR designs, are at risk for a starting point posterior to Blumensaat's line.
Gao, Fuqiang; Sun, Wei; Guo, Wanshou; Wang, Bailiang; Cheng, Liming; Li, Zirong
2016-01-01
Osteonecrosis of the femoral head (ONFH) following femoral neck fractures is a rare, yet severe, disorder in children and adolescents. This study evaluated the effectiveness of core decompression (CD) combined with implantation of bone marrow–derived cells (BMDC) and rhBMP-2 for osteonecrosis of femoral head (ONFH) after femoral neck fractures in children and adolescents. This study included 51 patients, aged 11.4–18.1 years, with ARCO stages I–III ONFH after femoral neck fractures between 2004 and 2010. The hips were divided into two groups based on whether the lateral pillar of the femoral head (LPFH) was preserved: LPFH and non-LPFH groups. All patients were followed up clinically and radiographically for a minimum of 5 years. 44 patients (86.3%) had improved clinical outcome. Radiologically, 9 of the 51 hips (17.6%) exhibited collapse onset or progression of the femoral head or narrowing of the hip joint space, and one patient in the non-LPFH group required hip arthroplasty due to the worsened syndrome. The technique provided an effective therapeutic option for children and adolescents with ONFH following femoral neck fractures. It relieves hip pain and prevents the progression of osteonecrosis in young patients lasting more than 5 years after surgery. PMID:27477836
Gupta, Vipul; Feng, Kent; Cheruvu, Pavan; Boyer, Nathan; Yeghiazarians, Yerem; Ports, Thomas A; Zimmet, Jeffrey; Shunk, Kendrick; Boyle, Andrew J
2014-09-01
Recent advances in technology have led to an increase in the use of bilateral femoral artery access and the requirement for large-bore access. Optimal access is in the common femoral artery (CFA), rather than higher (in the external iliac artery) or lower (in one of the branches of the CFA). However, there is a paucity of data in the literature about the relationship between bifurcation level of one CFA and the contralateral CFA. To define the prevalence of high bifurcation of the CFA and the relationship between bifurcation level on both sides, we performed a retrospective analysis of all patients with bilateral femoral angiography. From 4880 femoral angiograms performed at UCSF cardiac catheterization laboratory between 2005-2013, a total of 273 patients had bilateral femoral angiograms. The prevalence of low/normal, high, and very-high femoral bifurcations was 70%, 26%, and 4%, respectively, with no difference between sides. A high or very-high bifurcation significantly increased the likelihood of a high bifurcation on the contralateral side (odds ratio >3.0). Multivariable logistic regression analysis revealed age, gender, self-reported race, height, weight, and body mass index were not predictive of high or very-high bifurcations on either side. In conclusion, high femoral artery bifurcations are common and increase the likelihood of a high bifurcation of the contralateral femoral artery.
Bergschmidt, Philipp; Dammer, Rebecca; Zietz, Carmen; Finze, Susanne; Mittelmeier, Wolfram; Bader, Rainer
2016-06-01
Evaluation of the adhesive strength of femoral components to the bone cement is a relevant parameter for predicting implant safety. In the present experimental study, three types of cemented femoral components (metallic, ceramic and silica/silane-layered ceramic) of the bicondylar Multigen Plus knee system, implanted on composite femora were analysed. A pull-off test with the femoral components was performed after different load and several cementing conditions (four groups and n=3 components of each metallic, ceramic and silica/silane-layered ceramic in each group). Pull-off forces were comparable for the metallic and the silica/silane-layered ceramic femoral components (mean 4769 N and 4298 N) under standard test condition, whereas uncoated ceramic femoral components showed reduced pull-off forces (mean 2322 N). Loading under worst-case conditions led to decreased adhesive strength by loosening of the interface implant and bone cement using uncoated metallic and ceramic femoral components, respectively. Silica/silane-coated ceramic components were stably fixed even under worst-case conditions. Loading under high flexion angles can induce interfacial tensile stress, which could promote early implant loosening. In conclusion, a silica/silane-coating layer on the femoral component increased their adhesive strength to bone cement. Thicker cement mantles (>2 mm) reduce adhesive strength of the femoral component and can increase the risk of cement break-off.
Premature femoral neck physeal closure in Perthes' disease.
Bowen, J R; Schreiber, F C; Foster, B K; Wein, B K
1982-01-01
One hundred premature femoral neck physeal closures in 430 hips with Perthes' disease have occurred in two patterns central and lateral. Abnormal physeal growth can be demonstrated early by a narrowed physeal plate with overlying avascular epiphysis and marked metaphyseal reaction below. Subsequently, a bony bridge forms between the metaphysis and epiphysis. If the physeal closure is central, the mature hip will have a short femoral neck, a relatively round femoral head, a trochanter that has overgrown the femoral head, a short leg, and a mildly deformed acetabulum. If the physeal closure is lateral, the mature hip will have a femoral head that is externally tilted as the medial neck lengthens and the lateral neck remains short, a trochanter that has overgrown the femoral head, an oval femoral head, a short leg, and a deformed acetabulum. A physeal arrest is a contraindication for a varus osteotomy because it accentuates the deformity, especially in the greater trochanter. The leg-length discrepancy may be treated by epiphysiodesis of the contralateral femur, when necessary, and the abductor muscle insufficiency may be treated by an exercise program or distal and lateral transfer of the greater trochanter.
Development of a method for measuring femoral torsion using real-time ultrasound.
Hafiz, Eliza; Hiller, Claire E; Nicholson, Leslie L; Nightingale, E Jean; Clarke, Jillian L; Grimaldi, Alison; Eisenhuth, John P; Refshauge, Kathryn M
2014-07-01
Excessive femoral torsion has been associated with various musculoskeletal and neurological problems. To explore this relationship, it is essential to be able to measure femoral torsion in the clinic accurately. Computerized tomography (CT) and magnetic resonance imaging (MRI) are thought to provide the most accurate measurements but CT involves significant radiation exposure and MRI is expensive. The aim of this study was to design a method for measuring femoral torsion in the clinic, and to determine the reliability of this method. Details of design process, including construction of a jig, the protocol developed and the reliability of the method are presented. The protocol developed used ultrasound to image a ridge on the greater trochanter, and a customized jig placed on the femoral condyles as reference points. An inclinometer attached to the customized jig allowed quantification of the degree of femoral torsion. Measurements taken with this protocol had excellent intra- and inter-rater reliability (ICC2,1 = 0.98 and 0.97, respectively). This method of measuring femoral torsion also permitted measurement of femoral torsion with a high degree of accuracy. This method is applicable to the research setting and, with minor adjustments, will be applicable to the clinical setting.
Bilateral femoral neck stress fractures in military recruits with unilateral hip pain.
Moo, Ing How; Lee, Y H D; Lim, K K; Mehta, K V
2016-10-01
Femoral neck stress fractures are rare and can be easily missed and failure to diagnose these injuries early can lead to avascular necrosis, malunion and osteoarthritis. It is important to have a high index of suspicion for femoral neck stress fractures in military recruits. We present three cases of bilateral femoral neck fractures in military recruits, all presenting with unilateral hip symptoms and signs. All the asymptomatic contralateral hips had femoral neck stress fractures diagnosed by screening MRI. Tension type and displaced femoral neck fractures were treated surgically. All the fractures managed healing without complications. Military recruits with unilateral groin pain should have an early referral for MRI hip to rule out femoral neck stress fractures and those military personnel with ipsilateral femoral neck fracture should have MRI of the contralateral hip. Two of the patients had vitamin D deficiency, of which one had elevated parathyroid hormones and low bone mineral density. Our case series highlights the significance of vitamin D deficiency among military recruits. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Modular femoral component for conversion of previous hip surgery in total hip arthroplasty.
Goldstein, Wayne M; Branson, Jill J
2005-09-01
The conversion of previous hip surgery to total hip arthroplasty creates a durable construct that is anatomically accurate. Most femoral components with either cemented or cementless design have a fixed tapered proximal shape. The proximal femoral anatomy is changed due to previous hip surgery for fixation of an intertrochanteric hip fracture, proximal femoral osteotomy, or a fibular allograft for avascular necrosis. The modular S-ROM (DePuy Orthopaedics Inc., Warsaw, Ind) hip stem accommodates these issues and independently prepares the proximal and distal portion of the femur. In preparation and implantation, the S-ROM hip stem creates less hoop stresses on potentially fragile stress risers from screws and thin bone. The S-ROM hip stem also prepares a previously distorted anatomy by milling through cortical bone that can occlude the femoral medullar canals and recreate proper femoral anteversion and reduces the risk of intraoperative or postoperative periprosthetic fracture due to the flexible titanium-slotted stem. The S-ROM femoral stem is recommended for challenging total hip reconstructions.
[Femoral arteriovenous fistula: a late uncommon complication of central venous catheterization].
Conz, P A; Malagoli, A; Normanno, M; Munaro, D
2007-01-01
A 77-year-old woman was admitted due to AV graft thrombosis; given the technical impossibility of performing other native AV fistulas, we chose to insert a tunnelled central venous catheter. Considering the vascular history of the patient, the central venous catheter could not be placed into the internal jugular vein; it was therefore put into the left femoral vein. Following a 3-month-period of the catheter working properly, the patient was hospitalized due to sudden acute pain in the left thigh. In a few days the patient developed an important haematoma with serious anemization in the left lower limb. Ultrasonography showed the presence of a fistula between the left common femoral artery and the femoral vein, leading to the subsequent successful positioning of a stent into the common femoral artery through right trans-femoral access. Angiography examination showed the femoral vein patency along the proximal stretch with respect to the function of the tunnelled venous catheter.
Tellez, Armando; Dattilo, Raymond; Mustapha, Jihad A; Gongora, Carlos A; Hyon, Chelsea M; Palmieri, Taylor; Rousselle, Serge; Kaluza, Greg L; Granada, Juan F
2014-12-01
The efficacy of paclitaxel-coated balloons (PCB) for the treatment of superficial femoral artery (SFA) disease has been demonstrated in the clinical setting. Due to the high frequency of arterial calcification found in this vascular territory, the adjunctive use of atherectomy plus PCB has been proposed. In this study, we aimed to evaluate the biological effect on vascular healing and drug retention of this combination approach in the familial hypercholesterolaemic swine (FHS) model of femoral artery stenosis. Eleven femoral arteries (six superficial and five profunda arteries) were included. Vessels were injured (x2) over a 28-day period and all animals were maintained on a high cholesterol diet for 60 days following initial injury. Vessels were randomised to PCB (n=5) or orbital atherectomy system (OAS) plus PCB (n=6). At 28 days following therapy, vessels were followed with angiography, intravascular ultrasound (IVUS) and optical coherence tomography (OCT). Vessels were harvested for histological and pharmacokinetic analysis. Angiographic findings were comparable at termination between both groups. The OCT findings were comparable at termination. There were no differences in the vascular healing profile between both groups. The paclitaxel levels at termination were comparable between both groups (PCB=5.16 vs. OAS+PCB=3.03 ng/mg). In the experimental setting, the combination of OAS+PCB appears to be safe by demonstrating a vascular healing profile and drug tissue levels comparable to PCB only. The vascular effect of PCB may be enhanced by the use of OAS by decreasing plaque burden and cholesterol crystals.
Baksi, A John; Davies, Justin E; Hadjiloizou, Nearchos; Baruah, Resham; Unsworth, Beth; Foale, Rodney A; Korolkova, Olga; Siggers, Jennifer H; Francis, Darrel P; Mayet, Jamil; Parker, Kim H; Hughes, Alun D
2016-01-01
Wave reflection may be an important influence on blood pressure, but the extent to which reflections undergo attenuation during retrograde propagation has not been studied. We quantified retrograde transmission of a reflected wave created by occlusion of the left femoral artery in man. 20 subjects (age 31-83 years; 14 male) underwent invasive measurement of pressure and flow velocity with a sensor-tipped intra-arterial wire at multiple locations distal to the proximal aorta before, during and following occlusion of the left femoral artery by thigh cuff inflation. A numerical model of the circulation was also used to predict reflected wave transmission. Wave reflection was measured as the ratio of backward to forward wave energy (WRI) and the ratio of peak backward to forward pressure (Pb/Pf). Cuff inflation caused a marked reflection which was largest at 5-10 cm from the cuff (change (Δ) in WRI=0.50 (95% CI 0.38, 0.62); p<0.001, ΔPb/Pf=0.23 (0.18-0.29); p<0.001). The magnitude of the cuff-induced reflection decreased progressively at more proximal locations and was barely discernible at sites>40 cm from the cuff including in the proximal aorta. Numerical modelling gave similar predictions to those observed experimentally. Reflections due to femoral artery occlusion are markedly attenuated by the time they reach the proximal aorta. This is due to impedance mismatches of bifurcations traversed in the backward direction. This degree of attenuation is inconsistent with the idea of a large discrete reflected wave arising from the lower limb and propagating back into the aorta. Copyright © 2015. Published by Elsevier Ireland Ltd.
Scintigraphy of infected total hip arthroplasty (THA): A canine model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merkel, K.D.; Brown, M.L.; Fitzgerald, R.H.
1984-01-01
Differentiating low-grade sepsis from aseptic loosening of an orthopedic prosthesis is difficult. This study was designed to compare the ability of Tc-99m-HMDP, Ga-67, and In-111 leukocytes (WC) to differentiate low-grade sepsis from aseptic THA component loosening in a canine model. A canine THA was implanted in 14 dogs. Six dogs were given infected femoral components by injecting 10/sup 5/ colony-forming units of Staphylococcus aureus into the femoral canal 6y0 to 90 seconds prior to cementing. Four dogs had an aseptic loose femoral component, and four dogs had an aseptic tight femoral component (control). At six months all dogs were evaluatedmore » with X-ray, lab scintigraphy, and tissue quantitation of each tracer. Diagnosis was confirmed by histology and quantitative microbiology. White blood cell counts and differentials were normal in all dogs, and in only one out of six infected dogs was the sedimentation rate abnormal. X-rays were interpreted as possible infection in five dogs and probable infection in only one dog. In-111 WBC scans were more accurate than sequential Tc-Ga scans (sensitivity 94% vs 61%, specificity 86% vs 71% accuracy 90% vs 67%). Quantitative counting of gamma camera data and tissue samples demonstrated significantly (P < .01) higher accumulation of In-111 WBC about the infected than the loose or control component. No significant difference was demonstrated between the loose and septic components with TC-HMDP or Ga. These results correlate well and confirm our clinical data that In-111 WBC scanning is accurate and useful in the workup of the painful orthopedic prosthesis.« less
Deng, Guoying; Dai, Chenyun; Chen, Jinyuan; Ji, Anqi; Zhao, Jingpeng; Zhai, Yue; Kang, Yingjie; Liu, Xijian; Wang, Yin; Wang, Qiugen
2018-01-01
Methylprednisolone (MPS) is an important drug used in therapy of many diseases. However, osteonecrosis of the femoral head is a serious damage in the MPS treatment. Thus, it is imperative to develop new drugs to prevent the serious side effect of MPS. The potential interferences Se@SiO 2 nanocomposites may have to the therapeutic effect of methylprednisolone (MPS) were evaluated by classical therapeutic effect index of acute respiratory distress syndrome (ARDS), such as wet-to-dry weight ratio, inflammatory factors IL-1β and TNF-α. And oxidative stress species (ROS) index like superoxide dismutase (SOD) and glutathione (GSH) were tested. Then, the protection effects of Se@SiO 2 have in osteonecrosis of the femoral head (ONFH) were evaluated by micro CT, histologic analysis and Western-blot analysis. In the present study, we found that in the rat model of ARDS, Se@SiO 2 nanocomposites induced SOD and GSH indirectly to reduce ROS damage. The wet-to-dry weight ratio of lung was significantly decreased after MPS treatment compared with the control group, whereas the Se@SiO 2 did not affect the reduced wet-to-dry weight ratio of MPS. Se@SiO 2 also did not impair the effect of MPS on the reduction of inflammatory factors IL-1β and TNF-α, and on the alleviation of structural destruction. Furthermore, micro CT and histologic analysis confirmed that Se@SiO 2 significantly alleviate MPS-induced destruction of femoral head. Moreover, compared with MPS group, Se@SiO 2 could increase collagen II and aggrecan, and reduce the IL-1β level in the cartilage of femoral head. In addition, the biosafety of Se@SiO 2 in vitro and in vivo were supported by cell proliferation assay and histologic analysis of main organs from rat models. Se@SiO 2 nanocomposites have a protective effect in MPS-induced ONFH without influence on the therapeutic activity of MPS, suggesting the potential as effective drugs to avoid ONFH in MPS therapy.
Porous Se@SiO2 nanocomposites protect the femoral head from methylprednisolone-induced osteonecrosis
Chen, Jinyuan; Ji, Anqi; Zhao, Jingpeng; Zhai, Yue; Kang, Yingjie; Liu, Xijian; Wang, Yin; Wang, Qiugen
2018-01-01
Background Methylprednisolone (MPS) is an important drug used in therapy of many diseases. However, osteonecrosis of the femoral head is a serious damage in the MPS treatment. Thus, it is imperative to develop new drugs to prevent the serious side effect of MPS. Methods The potential interferences Se@SiO2 nanocomposites may have to the therapeutic effect of methylprednisolone (MPS) were evaluated by classical therapeutic effect index of acute respiratory distress syndrome (ARDS), such as wet-to-dry weight ratio, inflammatory factors IL-1β and TNF-α. And oxidative stress species (ROS) index like superoxide dismutase (SOD) and glutathione (GSH) were tested. Then, the protection effects of Se@SiO2 have in osteonecrosis of the femoral head (ONFH) were evaluated by micro CT, histologic analysis and Western-blot analysis. Results In the present study, we found that in the rat model of ARDS, Se@SiO2 nanocomposites induced SOD and GSH indirectly to reduce ROS damage. The wet-to-dry weight ratio of lung was significantly decreased after MPS treatment compared with the control group, whereas the Se@SiO2 did not affect the reduced wet-to-dry weight ratio of MPS. Se@SiO2 also did not impair the effect of MPS on the reduction of inflammatory factors IL-1β and TNF-α, and on the alleviation of structural destruction. Furthermore, micro CT and histologic analysis confirmed that Se@SiO2 significantly alleviate MPS-induced destruction of femoral head. Moreover, compared with MPS group, Se@SiO2 could increase collagen II and aggrecan, and reduce the IL-1β level in the cartilage of femoral head. In addition, the biosafety of Se@SiO2 in vitro and in vivo were supported by cell proliferation assay and histologic analysis of main organs from rat models. Conclusion Se@SiO2 nanocomposites have a protective effect in MPS-induced ONFH without influence on the therapeutic activity of MPS, suggesting the potential as effective drugs to avoid ONFH in MPS therapy. PMID:29606872
... top of the thighbone (femoral head) and its socket (acetabulum) in the pelvic bone. It can be ... hip, the femoral head rests comfortably in its socket. In babies with DDH, the femoral head moves ...
Cameron, James I; McCauley, Julie C; Kermanshahi, Arash Y; Bugbee, William D
2015-06-01
Distal femoral varus osteotomy may be used to treat valgus knee malalignment or to protect a knee compartment in which cartilage restoration surgery (such as osteochondral or meniscus allografting) has been performed. Medial closing-wedge osteotomy has demonstrated good success in treatment of osteoarthritis in published series, but few studies have evaluated distal femoral lateral opening-wedge osteotomy in terms of correction of deformity, pain and function, and survivorship. (1) Does lateral opening-wedge osteotomy lead to accurate correction? (2) What pain and function levels do patients experience after lateral opening-wedge osteotomy? (3) What are the nonunion, complication, and reoperation rates after lateral opening-wedge osteotomy? Between 2000 and 2010, we performed 40 distal femoral osteotomies. Two knees (two patients) underwent a medial closing-wedge osteotomy and were excluded from the present study. Thirty-eight knees (97%) in 36 patients were lateral opening-wedge varus-producing osteotomies; of those, 31 knees (82%) in 30 patients had followup at a minimum of 2 years (mean, 5 years; SD, 2; range, 2-12 years) and comprised the study population. The indications for osteotomy included symptomatic lateral compartment arthritis with clinical valgus deformity or a cartilage or meniscal defect in the lateral compartment with clinical valgus alignment. The study population was stratified into two groups based on reason for osteotomy: patients with isolated symptomatic lateral compartment arthritis (arthritis group; 19 knees [61%]) and patients who underwent joint preservation procedures including osteochondral allograft transplantation or meniscal allograft transplantation (joint preservation group; 12 knees [39%]). Data collection from our institution's osteotomy database included patient demographics, lower extremity coronal alignment, and operative details. Pain and function were measured preoperatively and postoperatively using the International Knee Documentation Committee (IKDC) score. Time to radiographic union, complications, and reoperations were recorded. Twenty-one of 31 knees had postoperative radiographic data available for review. Of these, seven of 15 knees in the arthritis group and three of six knees in the joint preservation group were within the correction goal of ± 3° from neutral mechanical alignment. In the arthritis group, the mean IKDC total score improved from 47 (SD, 15) preoperatively to 67 (SD, 10) postoperatively. In the joint preservation group, the mean IKDC total score improved from 36 (SD, 12) preoperatively to 62 (SD, 18) postoperatively. One nonunion occurred in the arthritis group. No postoperative complications were experienced. Ten knees in the arthritis group and six knees in the joint preservation group had additional surgery after the osteotomy, consisting primarily of hardware removal, arthroscopy for cartilage-related conditions, or conversion to arthroplasty. Survivorship at 5 years, with conversion to arthroplasty as the endpoint, was 74% in the arthritis group and 92% in the joint preservation group. Lateral opening-wedge distal femoral osteotomy was less accurate in correction of valgus deformity than expected, but the procedure was associated with improved knee pain and function scores. Our clinical and radiographic results are comparable to published series evaluating medial closing-wedge distal femoral osteotomy. Achieving our desired correction of ± 3° from neutral alignment was clinically difficult. An improved method of preoperative templating and refinement of the intraoperative technique may improve this. Future studies with more patients and longer followup will provide clarity on this topic. Level IV, therapeutic study.
Chun, So Hyun; Cho, Belong; Yang, Hyung-Kook; Ahn, Eunmi; Han, Min Kyu; Oh, Bumjo; Shin, Dong Wook; Son, Ki Young
Falls and fractures in older adults are often preventable, yet remain major health concerns as comprehensive physical function assessment may not be readily available. This study investigated whether simple timed up and go test (TUG) and unipedal stance test (UST) are effective in identifying people with an increased risk of fractures, femoral fractures, or admissions due to femoral fractures. Community-dwelling Korean older adults aged 66 years participated in the Korean National Screening Program for the Transitional Ages (n=557,648) between 2007 and 2010. Overall fractures, femoral fractures, and admissions due to femoral fracture during this period were outcome measures. The outcome measures were overall fractures, femoral fractures, and admissions due to femoral fracture after the health screening. The associations between inferior physical function test results and outcome measures were evaluated. A total of 523,502 subjects were followed-up for a mean period of 1.42 years, which resulted in 12,965 subjects with any fractures. Fracture data were retrieved from medical claims record. Subjects who performed poorly on one or both of the two physical function tests experienced higher number of overall fractures (aHR 1.21, 95% CI: 1.16-1.26), femoral fractures (aHR 1.80, 95% CI: 1.59-2.17), and admissions due to femoral fractures (aHR 1.85, 95% CI: 1.55-2.22) as compared to subjects with normal results on both tests. Combining TUG and UST was not superior to performing UST alone in predicting the increased risk of overall fractures (p=0.347), femoral fractures (p=0.402) or admissions due to femoral fractures (p=0.774). Poor performance on physical performance tests is associated with a higher risk of overall fractures, femoral fractures and admissions due to femoral fractures. The TUG and UST can be used to identify community-dwelling older individuals who are more vulnerable to fractures. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Evaluation of left ventricular function in anesthetized patients using femoral artery dP/dt(max).
De Hert, Stefan G; Robert, Dominique; Cromheecke, Stefanie; Michard, Frédéric; Nijs, Jan; Rodrigus, Inez E
2006-06-01
The purpose of this study was to compare dP/dt(max) estimated from a femoral artery pressure tracing to left ventricular (LV) dP/dt(max) during various alterations in myocardial loading and contractile function. Seventy patients scheduled for elective coronary artery bypass surgery. All patients were instrumented with a high-fidelity LV catheter, a pulmonary artery catheter, and a femoral arterial catheter. In 40 patients, hemodynamic measurements were performed before and after passive leg raising and before and after calcium administration (5 mg/kg); and in 30 other patients, hemodynamic measurements were performed before and after dobutamine infusion (5 microg/kg/min over 10 minutes). LV and femoral dP/dt(max) were significantly correlated (r = 0.82, p < 0.001), but femoral dP/dt(max) systematically underestimated LV dP/dt(max) (bias = -361 +/- 96 mmHg/s). Passive leg raising induced significant increases in central venous pressure and LV end-diastolic pressure, but femoral dP/dt(max), stroke volume, and LV dP/dt(max) remained unaltered. Calcium administration induced significant and marked increases in LV dP/dt(max) (23% +/- 9%) and femoral dP/dt(max) (37% +/- 14%) associated with a significant increase in stroke volume (9% +/- 2%). Dobutamine infusion also induced significant and marked increases in LV dP/dt(max) (25% +/- 8%) and femoral dP/dt(max) (35% +/- 12%) associated with a significant increase in stroke volume (14% +/- 3%). Overall, a very close linear relationship (r = 0.93) and a good agreement (bias = -5 +/- 17 mmHg/s) were found between changes in LV dP/dt(max) and changes in femoral dP/dt(max). A very close relationship was also observed between changes in LV dP/dt(max) and changes in femoral dP/dt(max) during each intervention (leg raising, calcium administration, and dobutamine infusion). Femoral dP/dt(max) underestimated LV dP/dt(max), but changes in femoral dP/dt(max) accurately reflected changes in LV dP/dt(max) during various interventions.