Brown, Rebecca; Johnstone, Edward D; Heazell, Alexander E P
2016-01-01
Continuous longer-term fetal monitoring has been proposed to address limitations of current technologies in the detection of fetal compromise. We aimed to assess professionals' views regarding current fetal-monitoring techniques and proposed longer-term continuous fetal monitoring. A questionnaire was designed and validated to assess obstetricians' and midwives' use of current fetal-monitoring techniques and their views towards continuous monitoring. 125 of 173 received responses (72% obstetricians, 28% midwives) were analysed. Professionals had the strongest views about supporting evidence for the most commonly employed fetal-monitoring techniques (maternal awareness of fetal movements, ultrasound assessment of fetal growth and umbilical artery Doppler). 45.1% of professionals agreed that a continuous monitoring device would be beneficial (versus 28.7% who disagreed); this perceived benefit was not influenced by professionals' views regarding current techniques or professional background. Professionals have limited experience of continuous fetal monitoring, but most respondents believed that it would increase maternal anxiety (64.3%) and would have concerns with its use in clinical practice (81.7%). Continuous fetal monitoring would be acceptable to the majority of professionals. However, development of these technologies must be accompanied by extended examination of professionals' and women's views to determine barriers to its introduction.
Fetal Heart Rate Monitoring during Labor
... of monitoring? • How is auscultation performed? • How is electronic fetal monitoring performed? • How is external monitoring performed? • ... method of periodically listening to the fetal heartbeat. Electronic fetal monitoring is a procedure in which instruments ...
Fetal monitoring during nonobstetric surgery: revisiting guidelines: a case report.
Rothschild, Tod J; Morel, Bruce; Pace, Benjamin; Fuks, Aleksandr M
2015-01-01
Nonobstetric surgery during pregnancy is not an infrequent occurrence. Guidelines for fetal monitoring during nonobstetric surgery are limited. We describe a case of appendectomy during third trimester, complicated by in utero fetal demise (IUFD). A 30-year-old, Caucasian woman underwent open appendectomy for suspected acute appendicitis. The procedure was complicated by IUFD. Fetal monitoring was done prior to but not during surgery. Guidelines for fetal monitoring were revised, recommending continuous electronic fetal monitoring when possible during third trimester nonobstetric surgery after appropriate patient counseling. A subsequent series of 5 uncomplicated appendectomies demonstrated no difficulty in implementing these guidelines. Continuous electronic fetal monitoring during third trimester nonobstetric surgery should be available and implemented after appropriate patient counseling. This approach reduces the risk of fetal mortality.
21 CFR 884.2620 - Fetal electroencephalographic monitor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal electroencephalographic monitor. 884.2620... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring Devices § 884.2620 Fetal electroencephalographic monitor. (a) Identification. A fetal...
21 CFR 884.2620 - Fetal electroencephalographic monitor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal electroencephalographic monitor. 884.2620... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring Devices § 884.2620 Fetal electroencephalographic monitor. (a) Identification. A fetal...
21 CFR 884.2620 - Fetal electroencephalographic monitor.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal electroencephalographic monitor. 884.2620... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring Devices § 884.2620 Fetal electroencephalographic monitor. (a) Identification. A fetal...
21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal ultrasonic monitor and accessories. 884.2660... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring Devices § 884.2660 Fetal ultrasonic monitor and accessories. (a) Identification. A fetal ultrasonic...
21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal ultrasonic monitor and accessories. 884.2660... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring Devices § 884.2660 Fetal ultrasonic monitor and accessories. (a) Identification. A fetal ultrasonic...
21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal ultrasonic monitor and accessories. 884.2660... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring Devices § 884.2660 Fetal ultrasonic monitor and accessories. (a) Identification. A fetal ultrasonic...
21 CFR 884.2620 - Fetal electroencephalographic monitor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal electroencephalographic monitor. 884.2620... Devices § 884.2620 Fetal electroencephalographic monitor. (a) Identification. A fetal electroencephalographic monitor is a device used to detect, measure, and record in graphic form (by means of one or more...
21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal ultrasonic monitor and accessories. 884.2660... Devices § 884.2660 Fetal ultrasonic monitor and accessories. (a) Identification. A fetal ultrasonic monitor is a device designed to transmit and receive ultrasonic energy into and from the pregnant woman...
Trans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry
NASA Astrophysics Data System (ADS)
Zourabian, Anna; Siegel, Andrew M.; Chance, Britton; Ramanujam, Nirmala; Rode, Martha; Boas, David A.
2000-10-01
Pulse oximetry (oxygen saturation monitoring) has markedly improved medical care in many fields, including anesthesiology, intensive care, and newborn intensive care. In obstetrics, fetal heart rate monitoring remains the standard for intrapartum assessment of fetal well being. Fetal oxygen saturation monitoring is a new technique currently under development. It is potentially superior to electronic fetal heart rate monitoring (cardiotocography) because it allows direct assessment of both the fetal oxygen status and fetal tissue perfusion. Here we present the analysis for determining the most optimal wavelength selection for pulse oximetry. The wavelengths we chose as the most optimal are the first in the range of 670 - 720 nm and the second in the range of 825 - 925 nm. Further, we discuss the possible systematic errors during our measurements and their contribution to the obtained saturation results. We present feasibility studies for fetal pulse oximetry, monitored noninvasively through the maternal abdomen. Our preliminary experiments show that the fetal pulse can be discriminated from the maternal pulse and thus, in principle, the fetal arterial oxygen saturation can be obtained. We present the methodology for obtaining these data, and discuss the dependence of our measurements on the fetal position with respect to the optode assembly.
[Current status and recommendations for intrapartum monitoring of fetal heart rate].
Měchurová, A; Velebil, P; Hruban, L; Janků, P
2016-04-01
Monitoring of fetal heart rate is one of the basic components of obstetrical care, in which the cardiotocography remains the gold standard and screening method in early diagnosis of fetal hypoxia, even after introduction of other selective methods of intrauterine monitoring of fetal well-being. The review article is divided into several parts: pathophysiology of fetal oxygenation, fetal heart rate and changes of fetal hemodynamics, and rules for fetal heart rate auscultation. The main principles of cardiotocographic monitoring and evaluation of ante- and intrapartrum recordings according to the FIGO criteria from 1986 and evaluation of intrapartum recordings according to the 2015 FIGO recommendations are mentioned. At the end a comparative table of 1986 FIGO and 2015 FIGO criteria is presented. Review.
Internal fetal monitoring (image)
Internal fetal monitoring involves placing a electrode directly on the fetal scalp through the cervix. This test is performed to evaluate fetal heart rate and variability between beats, especially ...
Women's experiences of continuous fetal monitoring - a mixed-methods systematic review.
Crawford, Alexandra; Hayes, Dexter; Johnstone, Edward D; Heazell, Alexander E P
2017-12-01
Antepartum stillbirth is often preceded by detectable signs of fetal compromise, including changes in fetal heart rate and movement. It is hypothesized that continuous fetal monitoring could detect these signs more accurately and objectively than current forms of fetal monitoring and allow for timely intervention. This systematic review aimed to explore available evidence on women's experiences of continuous fetal monitoring to investigate its acceptability before clinical implementation and to inform clinical studies. Systematic searching of four electronic databases (Embase, PsycINFO, MEDLINE and CINAHL), using key terms defined by initial scoping searches, identified a total of 35 studies. Following title and abstract screening by two independent researchers, five studies met the inclusion criteria. Studies were not excluded based on language, methodology or quality assessment. An integrative methodology was used to synthesize qualitative and quantitative data together. Forms of continuous fetal monitoring used included Monica AN24 monitors (n = 4) and phonocardiography (n = 1). Four main themes were identified: practical limitations of the device, negative emotions, positive perceptions, and device implementation. Continuous fetal monitoring was reported to have high levels of participant satisfaction and was preferred by women to intermittent cardiotocography. This review suggests that continuous fetal monitoring is accepted by women. However, it has also highlighted both the paucity and heterogeneity of current studies and suggests that further research should be conducted into women's experiences of continuous fetal monitoring before such devices can be used clinically. © 2017 Nordic Federation of Societies of Obstetrics and Gynecology.
Prototype of a wearable system for remote fetal monitoring during pregnancy.
Fanelli, Andrea; Ferrario, Manuela; Piccini, Luca; Andreoni, Giuseppe; Matrone, Giulia; Magenes, Giovanni; Signorini, Maria G
2010-01-01
Fetal Heart Rate (FHR) monitoring gives important information about the fetus health state during pregnancy. This paper presents a new prototype for remote fetal monitoring. The device will allow to monitor FHR in a domiciliary context and to send fetal ECG traces to a hospital facility, where clinicians can interpret them. In this way the mother could receive prompt feedback about fetal wellbeing. The system is characterized by two units: (i) a wearable unit endowed with textile electrodes for abdominal ECG recordings and with a Field Programmable Gate Array (FPGA) board for fetal heart rate (FHR) extraction; (ii) a dock station for the transmission of the data through the telephone line. The system will allow to reduce costs in fetal monitoring, improving the assessment of fetal conditions. The device is actually in development state. In this paper, the most crucial aspects behind its fulfillment are discussed.
Fuchs, Tomasz; Pomorski, Michał; Grobelak, Krzysztof; Tomiałowicz, Marek; Zimmer, Mariusz
2014-01-01
Fetal electrocardiography is one of the methods for monitoring the well-being of the fetus. Signal loss limits the proper interpretation of electrocardiogram traces. The aim of this study was to assess the average signal loss in non-invasive abdominal fetal electrocardiogram (fECG) monitoring using the KOMPOREL fetal monitoring system (ITAM, Zabrze, Poland) in women between 28 and 42 week of pregnancy. The results were compared to FIGO (International Federation of Gynaecology and Obstetric) and DGGG (Deutsche Gesellschaft für Gynäkologie und Geburtshilfe e.V.) recommendations concerning fetal heart monitoring. The correlation between fetal ECG signal quality, week of pregnancy and patient BMI was evaluated. 773 pregnant women, hospitalized and diagnosed in the Department of Gynecology and Obstetrics, Wroclaw Medical University, underwent 30 min of abdominal fECG recordings using the KOMPOREL fetal monitoring system. The average signal loss in abdominal fECG monitoring in the study group was 32%. FIGO recommendations describe an acceptable fetal signal loss of 20%. In our study, 46% (357/773) of the recordings were up to FIGO standards, with fetal heart rate success rates above 80%. According to DGGG guidelines, with acceptable fetal signal loss of 15%, only 39% (303/773) of the recordings could be assessed as accurate. No correlation between fECG signal quality, week of pregnancy and patient BMI was proved. The average signal loss in abdominal fECG monitoring in our study group was 32%. Low fECG signal quality may constitute a potentially limiting factor of the described fetal heart monitoring system. No relationship between fECG signal quality, week of pregnancy and patient BMI was proved.
NASA Astrophysics Data System (ADS)
Zourabian, Anna; Boas, David A.
2001-06-01
Pulse oximetry (oxygen saturation monitoring) has markedly improved medical care in many fields, including anesthesiology, intensive care, and newborn intensive care. In obstetrics, fetal heart rate monitoring remains the standard for intrapartum assessment of fetal well being. Fetal oxygen saturation monitoring is a new technique currently under development. It is potentially superior to electronic fetal heart rate monitoring (cardiotocography) because it allows direct assessment of both fetal oxygen status and fetal tissue perfusion. Here we present the analysis for determining the most optimal wavelength selection for pulse oximetry. The wavelengths we chose as the most optimal are: the first in the range of 670-720nm and the second in the range of 825-925nm. Further we discuss the possible systematic errors during our measurements, and their contribution to the obtained saturation results.
A Mobile Multi-Agent Information System for Ubiquitous Fetal Monitoring
Su, Chuan-Jun; Chu, Ta-Wei
2014-01-01
Electronic fetal monitoring (EFM) systems integrate many previously separate clinical activities related to fetal monitoring. Promoting the use of ubiquitous fetal monitoring services with real time status assessments requires a robust information platform equipped with an automatic diagnosis engine. This paper presents the design and development of a mobile multi-agent platform-based open information systems (IMAIS) with an automated diagnosis engine to support intensive and distributed ubiquitous fetal monitoring. The automatic diagnosis engine that we developed is capable of analyzing data in both traditional paper-based and digital formats. Issues related to interoperability, scalability, and openness in heterogeneous e-health environments are addressed through the adoption of a FIPA2000 standard compliant agent development platform—the Java Agent Development Environment (JADE). Integrating the IMAIS with light-weight, portable fetal monitor devices allows for continuous long-term monitoring without interfering with a patient’s everyday activities and without restricting her mobility. The system architecture can be also applied to vast monitoring scenarios such as elder care and vital sign monitoring. PMID:24452256
Telefetalcare: a first prototype of a wearable fetal electrocardiograph.
Fanelli, A; Signorini, M G; Ferrario, M; Perego, P; Piccini, L; Andreoni, G; Magenes, G
2011-01-01
Fetal heart rate monitoring is fundamental to infer information about fetal health state during pregnancy. The cardiotocography (CTG) is the most common antepartum monitoring technique. Abdominal ECG recording represents the most valuable alternative to cardiotocography, as it allows passive, non invasive and long term fetal monitoring. Unluckily fetal ECG has low SNR and needs to be extracted from abdominal recordings using ad hoc algorithms. This work describes a prototype of a wearable fetal ECG electrocardiograph. The system has flat band frequency response between 1-60 Hz and guarantees good signal quality. It was tested on pregnant women between the 30(th) and 34(th) gestational week. Several electrodes configurations were tested, in order to identify the best solution. Implementation of a simple algorithm for FECG extraction permitted the reliable detection of maternal and fetal QRS complexes. The system will allow continuative and deep screening of fetal heart rate, introducing the possibility of home fetal monitoring.
Fetal heart and uterine contraction monitor (image)
The fetal heart monitor and uterine contraction monitor provide a continuous record of the baby's heart rate and the mother's contraction rate as labor progresses. This device can provide early warning of fetal distress.
Chen, Han-Yang; Chauhan, Suneet P; Ananth, Cande V; Vintzileos, Anthony M; Abuhamad, Alfred Z
2011-06-01
To examine the association between electronic fetal heart rate monitoring and neonatal and infant mortality, as well as neonatal morbidity. We used the United States 2004 linked birth and infant death data. Multivariable log-binomial regression models were fitted to estimate risk ratio for association between electronic fetal heart rate monitoring and mortality, while adjusting for potential confounders. In 2004, 89% of singleton pregnancies had electronic fetal heart rate monitoring. Electronic fetal heart rate monitoring was associated with significantly lower infant mortality (adjusted relative risk, 0.75); this was mainly driven by the lower risk of early neonatal mortality (adjusted relative risk, 0.50). In low-risk pregnancies, electronic fetal heart rate monitoring was associated with decreased risk for Apgar scores <4 at 5 minutes (relative risk, 0.54); in high-risk pregnancies, with decreased risk of neonatal seizures (relative risk, 0.65). In the United States, the use of electronic fetal heart rate monitoring was associated with a substantial decrease in early neonatal mortality and morbidity that lowered infant mortality. Copyright © 2011 Mosby, Inc. All rights reserved.
Biomedical Equipment Maintenance Career Ladder, AFSC 918X0
1989-01-01
incubators, fetal heart monitors, and vital sign monitors. In comparison, higher percent- ages of the 5-skill level group maintain x-ray equipment...ECG) Monitors 87 Hypo/Hyperthermia Units 85 Incubators 85 Audiometer Systems 84 Blood Pressure Monitors, Automatic 81 Fetal Heart Monitors 80 X-Ray...01462 VERIFY CALIBRATION OF FETAL HEART MONITORS 100 G281 PERFORM OPERATIONAL INSPECTIONS OF VITAL SIGN MONITORS 100 01435 PERFORM PREVENTIVE
NASA Astrophysics Data System (ADS)
Khokhlova, L. A.; Seleznev, A. I.; Zhdanov, D. S.; Zemlyakov, I. Yu; Kiseleva, E. Yu
2016-01-01
The problem of monitoring fetal health is topical at the moment taking into account a reduction in the level of fertile-age women's health and changes in the concept of perinatal medicine with reconsideration of live birth criteria. Fetal heart rate monitoring is a valuable means of assessing fetal health during pregnancy. The routine clinical measurements are usually carried out by the means of ultrasound cardiotocography. Although the cardiotocography monitoring provides valuable information on the fetal health status, the high quality ultrasound devices are expensive, they are not available for home care use. The recommended number of measurement is also limited. The passive and fully non-invasive acoustic recording provides an alternative low-cost measurement method. The article describes a device for fetal and maternal health monitoring by analyzing the frequency and periodicity of heart beats by means of acoustic signal received on the maternal abdomen. Based on the usage of this device a phonocardiographic fetal telemedicine system, which will allow to reduce the antenatal fetal mortality rate significantly due to continuous monitoring over the state of fetus regardless of mother's location, can be built.
Detection and Processing Techniques of FECG Signal for Fetal Monitoring
2009-01-01
Fetal electrocardiogram (FECG) signal contains potentially precise information that could assist clinicians in making more appropriate and timely decisions during labor. The ultimate reason for the interest in FECG signal analysis is in clinical diagnosis and biomedical applications. The extraction and detection of the FECG signal from composite abdominal signals with powerful and advance methodologies are becoming very important requirements in fetal monitoring. The purpose of this review paper is to illustrate the various methodologies and developed algorithms on FECG signal detection and analysis to provide efficient and effective ways of understanding the FECG signal and its nature for fetal monitoring. A comparative study has been carried out to show the performance and accuracy of various methods of FECG signal analysis for fetal monitoring. Finally, this paper further focused some of the hardware implementations using electrical signals for monitoring the fetal heart rate. This paper opens up a passage for researchers, physicians, and end users to advocate an excellent understanding of FECG signal and its analysis procedures for fetal heart rate monitoring system. PMID:19495912
Tapia-Conyer, Roberto; Lyford, Shelley; Saucedo, Rodrigo; Casale, Michael; Gallardo, Hector; Becerra, Karen; Mack, Jonathan; Mujica, Ricardo; Estrada, Daniel; Sanchez, Antonio; Sabido, Ramon; Meier, Carlos; Smith, Joseph
2015-01-01
Background. Fetal and neonatal morbidity and mortality are significant problems in developing countries; remote maternal-fetal monitoring offers promise in addressing this challenge. The Gary and Mary West Health Institute and the Instituto Carlos Slim de la Salud conducted a demonstration project of wirelessly enabled antepartum maternal-fetal monitoring in the state of Yucatán, Mexico, to assess whether there were any fundamental barriers preventing deployment and use. Methods. Following informed consent, high-risk pregnant women at 27–29 weeks of gestation at the Chemax primary clinic participated in remote maternal-fetal monitoring. Study participants were randomized to receive either prototype wireless monitoring or standard-of-care. Feasibility was evaluated by assessing technical aspects of performance, adherence to monitoring appointments, and response to recommendations. Results. Data were collected from 153 high-risk pregnant indigenous Mayan women receiving either remote monitoring (n = 74) or usual standard-of-care (n = 79). Remote monitoring resulted in markedly increased adherence (94.3% versus 45.1%). Health outcomes were not statistically different in the two groups. Conclusions. Remote maternal-fetal monitoring is feasible in resource-constrained environments and can improve maternal compliance for monitoring sessions. Improvement in maternal-fetal health outcomes requires integration of such technology into sociocultural context and addressing logistical challenges of access to appropriate emergency services. PMID:25691900
Operational Definitions of Labor and Delivery Nursing Activities.
1987-07-01
assess and record fetal heart rate. (S 2406 r) ZO!3 FETAL ELECTRODE INSERTION (RN): position patient, insert fetal electrode, secure monitor leads...to leg plate to patient’s lower extremity, connect, assess and record fetal heart rate. (S2405r) Z014 FETAL ELECTRODE INSERTION/INTRAUTERINE CATHETER...INSERTION, ASSIST: position patient for procedure, secure monitor Teads to patient’s lower extremity, assess and record fetal heart tones. Set up
21 CFR 884.2620 - Fetal electroencephalographic monitor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal electroencephalographic monitor. 884.2620 Section 884.2620 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring Devices § 884.2620 Fetal...
A Labor and Delivery Patient Classification System Based on Direct Nursing Care Time
1991-08-01
physician 2409 Internal or external monitoring--uterine contraction/ fetal heart tones 2410 Manual contraction assessment 2411 Pitocin induction...assisting physician 2412 Fetal heart tones, manual 2413 Fetal heart tones, doppler 2414 Fetal scalp sampling, assisting physician 241E Routine delivery room... heart tones, ultrasonic transducer 2437 Monitoring fetal heart tones, ultrasonic transducer and uterine contraction, tocotransducer 69 Appendix B: List
A novel modality for intrapartum fetal heart rate monitoring.
Ashwal, Eran; Shinar, Shiri; Aviram, Amir; Orbach, Sharon; Yogev, Yariv; Hiersch, Liran
2017-11-02
Intrapartum fetal heart rate (FHR) monitoring is well recommended during labor to assess fetal wellbeing. Though commonly used, the external Doppler and fetal scalp electrode monitor have significant shortcomings. Lately, non-invasive technologies were developed as possible alternatives. The objective of this study is to compare the accuracy of FHR trace using novel Electronic Uterine Monitoring (EUM) to that of external Doppler and fetal scalp electrode monitor. A comparative study conducted in a single tertiary medical center. Intrapartum FHR trace was recorded simultaneously using three different methods: internal fetal scalp electrode, external Doppler, and EUM. The latter, a multichannel electromyogram (EMG) device acquires a uterine signal and maternal and fetal electrocardiograms. FHR traces obtained from all devices during the first and second stages of labor were analyzed. Positive percent of agreement (PPA) and accuracy (by measuring root means square error between observed and predicted values) of EUM and external Doppler were both compared to internal scalp electrode monitoring. A Bland-Altman agreement plot was used to compare the differences in FHR trace between all modalities. For momentary recordings of fetal heart rate <110 bpm or >160 bpm level of agreement, sensitivity, and specificity were also evaluated. Overall, 712,800 FHR momentary recordings were obtained from 33 parturients. Although both EUM and external Doppler highly correlated with internal scalp electrode monitoring (r 2 = 0.98, p < .001 for both methods), the accuracy of EUM was significantly higher than external Doppler (99.0% versus 96.6%, p < .001). In addition, for fetal heart rate <110 bpm or >160 bpm, the PPA, sensitivity, and specificity of EUM as compared with internal fetal scalp electrode, were significantly greater than those of external Doppler (p < .001). Intrapartum FHR using EUM is both valid and accurate, yielding higher correlations with internal scalp electrode monitoring than external Doppler. As such, it may provide a good framework for non-invasive evaluation of intrapartum FHR.
21 CFR 884.2675 - Fetal scalp circular (spiral) electrode and applicator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Gynecological Monitoring Devices § 884.2675 Fetal scalp circular (spiral) electrode and applicator. (a... monitoring device by a shallow subcutaneous puncture of fetal scalp tissue with a curved needle or needles... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal scalp circular (spiral) electrode and...
21 CFR 884.2675 - Fetal scalp circular (spiral) electrode and applicator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Gynecological Monitoring Devices § 884.2675 Fetal scalp circular (spiral) electrode and applicator. (a... monitoring device by a shallow subcutaneous puncture of fetal scalp tissue with a curved needle or needles... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal scalp circular (spiral) electrode and...
21 CFR 884.2675 - Fetal scalp circular (spiral) electrode and applicator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Gynecological Monitoring Devices § 884.2675 Fetal scalp circular (spiral) electrode and applicator. (a... monitoring device by a shallow subcutaneous puncture of fetal scalp tissue with a curved needle or needles... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal scalp circular (spiral) electrode and...
21 CFR 884.2675 - Fetal scalp circular (spiral) electrode and applicator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Gynecological Monitoring Devices § 884.2675 Fetal scalp circular (spiral) electrode and applicator. (a... monitoring device by a shallow subcutaneous puncture of fetal scalp tissue with a curved needle or needles... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal scalp circular (spiral) electrode and...
21 CFR 884.2675 - Fetal scalp circular (spiral) electrode and applicator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Gynecological Monitoring Devices § 884.2675 Fetal scalp circular (spiral) electrode and applicator. (a... monitoring device by a shallow subcutaneous puncture of fetal scalp tissue with a curved needle or needles... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal scalp circular (spiral) electrode and...
Cerebral palsy litigation: change course or abandon ship.
Sartwelle, Thomas P; Johnston, James C
2015-06-01
The cardinal driver of cerebral palsy litigation is electronic fetal monitoring, which has continued unabated for 40 years. Electronic fetal monitoring, however, is based on 19th-century childbirth myths, a virtually nonexistent scientific foundation, and has a false positive rate exceeding 99%. It has not affected the incidence of cerebral palsy. Electronic fetal monitoring has, however, increased the cesarian section rate, with the expected increase in mortality and morbidity risks to mothers and babies alike. This article explains why electronic fetal monitoring remains endorsed as efficacious in the worlds' labor rooms and courtrooms despite being such a feeble medical modality. It also reviews the reasons professional organizations have failed to condemn the use of electronic fetal monitoring in courtrooms. The failures of tort reform, special cerebral palsy courts, and damage limits to stem the escalating litigation are discussed. Finally, the authors propose using a currently available evidence rule-the Daubert doctrine that excludes "junk science" from the courtroom-as the beginning of the end to cerebral palsy litigation and electronic fetal monitoring's 40-year masquerade as science. © The Author(s) 2014.
Understanding fetal physiology and second line monitoring during labor.
Garabedian, C; De Jonckheere, J; Butruille, L; Deruelle, P; Storme, L; Houfflin-Debarge, V
2017-02-01
Cardiotocography (CTG) is a technique used to monitor intrapartum fetal condition and is one of the most common obstetric procedures. Second line methods of fetal monitoring have been developed in an attempt to reduce unnecessary interventions due to continuous cardiotocography and to better identify fetuses at risk of intrapartum asphyxia. The acid-base balance of the fetus is evaluated by fetal blood scalp samples, the modification of the myocardial oxygenation by the fetal ECG ST-segment analysis (STAN) and the autonomic nervous system by the power spectral analysis of the fetal heart variability. To correctly interpret the features observed on CTG traces or second line methods, it seems important to understand normal physiology during labor and the compensatory mechanisms of the fetus in case of hypoxemia. Therefore, the aim of this review is first to describe fetal physiology during labor and then to explain the modification of the second line monitoring during labor. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
When Pregnancy Goes Past Your Due Date
... have testing in a postterm pregnancy? • What is electronic fetal monitoring? • What is a nonstress test? • What ... some cases, delivery may be recommended. What is electronic fetal monitoring? Tests of fetal well-being use ...
Clinical relevance of fetal hemodynamic monitoring: Perinatal implications.
Pruetz, Jay D; Votava-Smith, Jodie; Miller, David A
2015-08-01
Comprehensive assessment of fetal wellbeing involves monitoring of fetal growth, placental function, central venous pressure, and cardiac function. Ultrasound evaluation of the fetus using 2D, color Doppler, and pulse-wave Doppler techniques form the foundation of antenatal diagnosis of structural anomalies, rhythm abnormalities and altered fetal circulation. Accurate and timely prenatal identification of the fetus at risk is critical for appropriate parental counseling, antenatal diagnostic testing, consideration for fetal intervention, perinatal planning, and coordination of postnatal care delivery. Fetal hemodynamic monitoring and serial assessment are vital to ensuring fetal wellbeing, particularly in the setting of complex congenital anomalies. A complete hemodynamic evaluation of the fetus gives important information on the likelihood of a smooth postnatal transition and contributes to ensuring the best possible outcome for the neonate. Copyright © 2015 Elsevier Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
The objective of the present study was to evaluate the use of audible chart-recorded doppler ultrasonography (DUS) to monitor both uterine blood flow and fetal heart rate (FHR) during pregnancy in dairy cattle. Possible applications of DUS include the monitoring of fetal distress when a pregnancy be...
Cleal, J K; Thomas, M; Hanson, M A; Paterson-Brown, S; Gardiner, H M; Green, L R
2010-03-01
To investigate whether a noninvasive fetal electrocardiography (fECG) system can identify cardiovascular responses to fetal hypoxaemia and validate the results using standard invasive fECG monitoring techniques. Prospective cohort study. Biological research facilities at The University of Southampton. Late gestation ovine fetuses; n = 5. Five fetal lambs underwent implantation of vascular catheters, umbilical cord occluder and invasive ECG chest electrodes under general anaesthesia (3% halothane/O(2)) at 119 days of gestation (term approximately 147 days of gestation). After 5 days of recovery blood pressure, blood gases, glucose and pH were monitored. At 124 and 125 days of gestation following a 10-minute baseline period a 90-second cord occlusion was applied. Noninvasive fetal ECG was recorded from maternal transabdominal electrodes using advanced signal-processing techniques, concurrently with invasive fECG recordings. Comparison of T:QRS ratios of the ECG waveform from noninvasive and invasive fECG monitoring systems. Our fECG monitoring system is able to demonstrate changes in waveforms during periods of hypoxaemia similar to those obtained invasively, which could indicate fetal distress. These findings may indicate a future use for noninvasive electrocardiography during human fetal monitoring both before and during labour in term and preterm pregnancies.
Randomised controlled trial of intrapartum fetal heart rate monitoring.
Mahomed, K; Nyoni, R; Mulambo, T; Kasule, J; Jacobus, E
1994-02-19
To compare effectiveness of different methods of monitoring intrapartum fetal heart rate. Prospective randomised controlled trial. Referral maternity hospital, Harare, Zimbabwe. 1255 women who were 37 weeks or more pregnant with singleton cephalic presentation and normal fetal heart rate before entry into study. Intermittent monitoring of fetal heart rate by electronic monitoring, Doppler ultrasound, use of Pinard stethoscope by a research midwife, or routine use of Pinard stethoscope by attending midwife. Abnormal fetal heart rate patterns, need for operative delivery for fetal distress, neonatal mortality, Apgar scores, admission to neonatal unit, neonatal seizures, and hypoxic ischaemic encephalopathy. Abnormalities in fetal heart rate were detected in 54% (172/318) of the electronic monitoring group, 32% (100/312) of the ultrasonography group, 15% (47/310) of the Pinard stethoscope group, and 9% (28/315) of the routine monitoring group. Caesarean sections were performed for 28% (89%), 24% (76), 10% (32), and 15% (46) of the four groups respectively. Neonatal outcome was best in the ultrasonography group: hypoxic ischaemic encephalopathy occurred in two, one, seven, and 10 cases in the four groups respectively; neonatal seizures occurred only in the last two groups (six and nine cases respectively); and deaths occurred in eight, two, five, and nine cases respectively. Abnormalities in fetal heart rate were more reliably detected by Doppler ultrasonography than with Pinard stethoscope, and its use resulted in good perinatal outcome. The use of relatively cheap ultrasound monitors should be further evaluated and promoted in obstetric units caring for high risk pregnancies in developing countries with scarce resources.
Randomised controlled trial of intrapartum fetal heart rate monitoring.
Mahomed, K.; Nyoni, R.; Mulambo, T.; Kasule, J.; Jacobus, E.
1994-01-01
OBJECTIVE--To compare effectiveness of different methods of monitoring intrapartum fetal heart rate. DESIGN--Prospective randomised controlled trial. SETTING--Referral maternity hospital, Harare, Zimbabwe. SUBJECTS--1255 women who were 37 weeks or more pregnant with singleton cephalic presentation and normal fetal heart rate before entry into study. INTERVENTIONS--Intermittent monitoring of fetal heart rate by electronic monitoring, Doppler ultrasound, use of Pinard stethoscope by a research midwife, or routine use of Pinard stethoscope by attending midwife. MAIN OUTCOME MEASURES--Abnormal fetal heart rate patterns, need for operative delivery for fetal distress, neonatal mortality, Apgar scores, admission to neonatal unit, neonatal seizures, and hypoxic ischaemic encephalopathy. RESULTS--Abnormalities in fetal heart rate were detected in 54% (172/318) of the electronic monitoring group, 32% (100/312) of the ultrasonography group, 15% (47/310) of the Pinard stethoscope group, and 9% (28/315) of the routine monitoring group. Caesarean sections were performed for 28% (89%), 24% (76), 10% (32), and 15% (46) of the four groups respectively. Neonatal outcome was best in the ultrasonography group: hypoxic ischaemic encephalopathy occurred in two, one, seven, and 10 cases in the four groups respectively; neonatal seizures occurred only in the last two groups (six and nine cases respectively); and deaths occurred in eight, two, five, and nine cases respectively. CONCLUSIONS--Abnormalities in fetal heart rate were more reliably detected by Doppler ultrasonography than with Pinard stethoscope, and its use resulted in good perinatal outcome. The use of relatively cheap ultrasound monitors should be further evaluated and promoted in obstetric units caring for high risk pregnancies in developing countries with scarce resources. PMID:8136665
Vullings, Rik; Verdurmen, Kim M J; Hulsenboom, Alexandra D J; Scheffer, Stephanie; de Lau, Hinke; Kwee, Anneke; Wijn, Pieter F F; Amer-Wåhlin, Isis; van Laar, Judith O E H; Oei, S Guid
2017-01-01
Reducing perinatal morbidity and mortality is one of the major challenges in modern health care. Analysing the ST segment of the fetal electrocardiogram was thought to be the breakthrough in fetal monitoring during labour. However, its implementation in clinical practice yields many false alarms and ST monitoring is highly dependent on cardiotocogram assessment, limiting its value for the prediction of fetal distress during labour. This study aims to evaluate the relation between physiological variations in the orientation of the fetal electrical heart axis and the occurrence of ST events. A post-hoc analysis was performed following a multicentre randomised controlled trial, including 1097 patients from two participating centres. All women were monitored with ST analysis during labour. Cases of fetal metabolic acidosis, poor signal quality, missing blood gas analysis, and congenital heart disease were excluded. The orientation of the fetal electrical heart axis affects the height of the initial T/QRS baseline, and therefore the incidence of ST events. We grouped tracings with the same initial baseline T/QRS value. We depicted the number of ST events as a function of the initial baseline T/QRS value with a linear regression model. A significant increment of ST events was observed with increasing height of the initial T/QRS baseline, irrespective of the fetal condition; correlation coefficient 0.63, p<0.001. The most frequent T/QRS baseline is 0.12. The orientation of the fetal electrical heart axis and accordingly the height of the initial T/QRS baseline should be taken into account in fetal monitoring with ST analysis.
Performance of a wearable acoustic system for fetal movement discrimination
Lai, Jonathan; Woodward, Richard; Alexandrov, Yuriy; ain Munnee, Qurratul; Lees, Christoph C.
2018-01-01
Fetal movements (FM) are a key factor in clinical management of high-risk pregnancies such as fetal growth restriction. While maternal perception of reduced FM can trigger self-referral to obstetric services, maternal sensation is highly subjective. Objective, reliable monitoring of fetal movement patterns outside clinical environs is not currently possible. A wearable and non-transmitting system capable of sensing fetal movements over extended periods of time would be extremely valuable, not only for monitoring individual fetal health, but also for establishing normal levels of movement in the population at large. Wearable monitors based on accelerometers have previously been proposed as a means of tracking FM, but such systems have difficulty separating maternal and fetal activity and have not matured to the level of clinical use. We introduce a new wearable system based on a novel combination of accelerometers and bespoke acoustic sensors as well as an advanced signal processing architecture to identify and discriminate between types of fetal movements. We validate the system with concurrent ultrasound tests on a cohort of 44 pregnant women and demonstrate that the garment is capable of both detecting and discriminating the vigorous, whole-body ‘startle’ movements of a fetus. These results demonstrate the promise of multimodal sensing for the development of a low-cost, non-transmitting wearable monitor for fetal movements. PMID:29734344
Performance of a wearable acoustic system for fetal movement discrimination.
Lai, Jonathan; Woodward, Richard; Alexandrov, Yuriy; Ain Munnee, Qurratul; Lees, Christoph C; Vaidyanathan, Ravi; Nowlan, Niamh C
2018-01-01
Fetal movements (FM) are a key factor in clinical management of high-risk pregnancies such as fetal growth restriction. While maternal perception of reduced FM can trigger self-referral to obstetric services, maternal sensation is highly subjective. Objective, reliable monitoring of fetal movement patterns outside clinical environs is not currently possible. A wearable and non-transmitting system capable of sensing fetal movements over extended periods of time would be extremely valuable, not only for monitoring individual fetal health, but also for establishing normal levels of movement in the population at large. Wearable monitors based on accelerometers have previously been proposed as a means of tracking FM, but such systems have difficulty separating maternal and fetal activity and have not matured to the level of clinical use. We introduce a new wearable system based on a novel combination of accelerometers and bespoke acoustic sensors as well as an advanced signal processing architecture to identify and discriminate between types of fetal movements. We validate the system with concurrent ultrasound tests on a cohort of 44 pregnant women and demonstrate that the garment is capable of both detecting and discriminating the vigorous, whole-body 'startle' movements of a fetus. These results demonstrate the promise of multimodal sensing for the development of a low-cost, non-transmitting wearable monitor for fetal movements.
1981-09-01
Change = 2311 (257) Teaching - Diabetic = 2313 (258) Labor Room Examination and Preparation, Routine = 2434 (259) Fetal Heart Tones, Manual = 2412 (260... Fetal Heart Tones, Doppler = 2413 (261) Dilatation and Effecement Assessment = 2403 (262) Dilatation and Effacement Assessment, Assisting Physician...Ultrasonic Transducer/Tocotransducer = 2435 (270) Monitoring Fetal Heart Tones, Ultrasonic Transducer = 2436 (271) Monitoring Fetal Heart Tones, Ultrasonic
Sartwelle, Thomas P.
2015-01-01
The cardinal driver of cerebral palsy litigation is electronic fetal monitoring, which has continued unabated for 40 years. Electronic fetal monitoring, however, is based on 19th-century childbirth myths, a virtually nonexistent scientific foundation, and has a false positive rate exceeding 99%. It has not affected the incidence of cerebral palsy. Electronic fetal monitoring has, however, increased the cesarian section rate, with the expected increase in mortality and morbidity risks to mothers and babies alike. This article explains why electronic fetal monitoring remains endorsed as efficacious in the worlds’ labor rooms and courtrooms despite being such a feeble medical modality. It also reviews the reasons professional organizations have failed to condemn the use of electronic fetal monitoring in courtrooms. The failures of tort reform, special cerebral palsy courts, and damage limits to stem the escalating litigation are discussed. Finally, the authors propose using a currently available evidence rule—the Daubert doctrine that excludes “junk science” from the courtroom—as the beginning of the end to cerebral palsy litigation and electronic fetal monitoring’s 40-year masquerade as science. PMID:25183322
Nageotte, Michael P
2015-06-01
Electronic fetal heart rate monitoring is a widely utilized means of assessment of fetal status during labor. Whereas little evidence exists regarding efficacy, this modality continues to be used extensively in every modern labor and delivery unit in developed countries. It is of importance that all providers of health care to the woman in labor and her newborn have a clear understanding of the basic pathophysiology of fetal heart rate monitoring and an appreciation for labor course and concerns as they arise in order to optimize outcomes and patient safety. Copyright © 2015 Elsevier Ltd. All rights reserved.
Passive Fetal Heart Monitoring System
NASA Technical Reports Server (NTRS)
Zuckerwar, Allan J. (Inventor); Mowrey, Dennis L. (Inventor)
2003-01-01
A fetal heart monitoring system and method for detecting and processing acoustic fetal heart signals transmitted by different signal transmission modes. One signal transmission mode, the direct contact mode, occurs in a first frequency band when the fetus is in direct contact with the maternal abdominal wall. Another signal transmission mode, the fluid propagation mode, occurs in a second frequency band when the fetus is in a recessed position with no direct contact with the maternal abdominal wall. The second frequency band is relatively higher than the first frequency band. The fetal heart monitoring system and method detect and process acoustic fetal heart signals that are in the first frequency band and in the second frequency band.
Cohen, Wayne R; Hayes-Gill, Barrie
2014-06-01
To evaluate the performance of external electronic fetal heart rate and uterine contraction monitoring according to maternal body mass index. Secondary analysis of prospective equivalence study. Three US urban teaching hospitals. Seventy-four parturients with a normal term pregnancy. The parent study assessed performance of two methods of external fetal heart rate monitoring (abdominal fetal electrocardiogram and Doppler ultrasound) and of uterine contraction monitoring (electrohystero-graphy and tocodynamometry) compared with internal monitoring with fetal scalp electrode and intrauterine pressure transducer. Reliability of external techniques was assessed by the success rate and positive percent agreement with internal methods. Bland-Altman analysis determined accuracy. We analyzed data from that study according to maternal body mass index. We assessed the relationship between body mass index and monitor performance with linear regression, using body mass index as the independent variable and measures of reliability and accuracy as dependent variables. There was no significant association between maternal body mass index and any measure of reliability or accuracy for abdominal fetal electrocardiogram. By contrast, the overall positive percent agreement for Doppler ultrasound declined (p = 0.042), and the root mean square error from the Bland-Altman analysis increased in the first stage (p = 0.029) with increasing body mass index. Uterine contraction recordings from electrohysterography and tocodynamometry showed no significant deterioration related to maternal body mass index. Accuracy and reliability of fetal heart rate monitoring using abdominal fetal electrocardiogram was unaffected by maternal obesity, whereas performance of ultrasound degraded directly with maternal size. Both electrohysterography and tocodynamometry were unperturbed by obesity. © 2014 Nordic Federation of Societies of Obstetrics and Gynecology.
Low-complexity R-peak detection for ambulatory fetal monitoring.
Rooijakkers, Michael J; Rabotti, Chiara; Oei, S Guid; Mischi, Massimo
2012-07-01
Non-invasive fetal health monitoring during pregnancy is becoming increasingly important because of the increasing number of high-risk pregnancies. Despite recent advances in signal-processing technology, which have enabled fetal monitoring during pregnancy using abdominal electrocardiogram (ECG) recordings, ubiquitous fetal health monitoring is still unfeasible due to the computational complexity of noise-robust solutions. In this paper, an ECG R-peak detection algorithm for ambulatory R-peak detection is proposed, as part of a fetal ECG detection algorithm. The proposed algorithm is optimized to reduce computational complexity, without reducing the R-peak detection performance compared to the existing R-peak detection schemes. Validation of the algorithm is performed on three manually annotated datasets. With a detection error rate of 0.23%, 1.32% and 9.42% on the MIT/BIH Arrhythmia and in-house maternal and fetal databases, respectively, the detection rate of the proposed algorithm is comparable to the best state-of-the-art algorithms, at a reduced computational complexity.
NASA Technical Reports Server (NTRS)
Zahorian, Stephen A. (Inventor); Livingston, David L. (Inventor); Pretlow, III, Robert A. (Inventor)
1996-01-01
An apparatus for acquiring signals emitted by a fetus, identifying fetal heart beats and determining a fetal heart rate. Multiple sensor signals are outputted by a passive fetal heart rate monitoring sensor. Multiple parallel nonlinear filters filter these multiple sensor signals to identify fetal heart beats in the signal data. A processor determines a fetal heart rate based on these identified fetal heart beats. The processor includes the use of a figure of merit weighting of heart rate estimates based on the identified heart beats from each filter for each signal. The fetal heart rate thus determined is outputted to a display, storage, or communications channel. A method for enhanced fetal heart beat discrimination includes acquiring signals from a fetus, identifying fetal heart beats from the signals by multiple parallel nonlinear filtering, and determining a fetal heart rate based on the identified fetal heart beats. A figure of merit operation in this method provides for weighting a plurality of fetal heart rate estimates based on the identified fetal heart beats and selecting the highest ranking fetal heart rate estimate.
NASA Technical Reports Server (NTRS)
Zahorian, Stephen A. (Inventor); Livingston, David L. (Inventor); Pretlow, Robert A., III (Inventor)
1994-01-01
An apparatus for acquiring signals emitted by a fetus, identifying fetal heart beats and determining a fetal heart rate is presented. Multiple sensor signals are outputted by a passive fetal heart rate monitoring sensor. Multiple parallel nonlinear filters filter these multiple sensor signals to identify fetal heart beats in the signal data. A processor determines a fetal heart rate based on these identified fetal heart beats. The processor includes the use of a figure of merit weighting of heart rate estimates based on the identified heart beats from each filter for each signal. The fetal heart rate thus determined is outputted to a display, storage, or communications channel. A method for enhanced fetal heart beat discrimination includes acquiring signals from a fetus, identifying fetal heart beats from the signals by multiple parallel nonlinear filtering, and determining a fetal heart rate based on the identified fetal heart beats. A figure of merit operation in this method provides for weighting a plurality of fetal heart rate estimates based on the identified fetal heart beats and selecting the highest ranking fetal heart rate estimate.
21 CFR 884.2740 - Perinatal monitoring system and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... monitoring system is a device used to show graphically the relationship between maternal labor and the fetal heart rate by means of combining and coordinating uterine contraction and fetal heart monitors with...
21 CFR 884.2740 - Perinatal monitoring system and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... monitoring system is a device used to show graphically the relationship between maternal labor and the fetal heart rate by means of combining and coordinating uterine contraction and fetal heart monitors with...
21 CFR 884.2740 - Perinatal monitoring system and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... monitoring system is a device used to show graphically the relationship between maternal labor and the fetal heart rate by means of combining and coordinating uterine contraction and fetal heart monitors with...
21 CFR 884.2740 - Perinatal monitoring system and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... monitoring system is a device used to show graphically the relationship between maternal labor and the fetal heart rate by means of combining and coordinating uterine contraction and fetal heart monitors with...
21 CFR 884.2740 - Perinatal monitoring system and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... monitoring system is a device used to show graphically the relationship between maternal labor and the fetal heart rate by means of combining and coordinating uterine contraction and fetal heart monitors with...
[Labor monitoring in high-risk situations].
Houfflin-Debarge, V; Closset, E; Deruelle, P
2008-02-01
Intrapartum asphyxia is increased in several situations such as intrauterine growth retardation, preterm labor, postdate pregnancy or maternal diabetes. In all these cases, fetal heart rate monitoring should be preferred to intermittent auscultation. Fetal scalp blood pH or lactates can be used to identify fetuses at risk of intrapartum asphyxia. However, fetal scalp blood sampling should not delay delivery in case of severe abnormal fetal heart rate as fetal asphyxia could occur rapidly in theses high-risk pregnancies. Data is insufficient to recommend fetal pulse oximetry or ECG analysis. Research should be undertaken to evaluate their performance in these situations.
Update on Fetal Monitoring: Overview of Approaches and Management of Category II Tracings.
Raghuraman, Nandini; Cahill, Alison G
2017-12-01
Electronic fetal monitoring (EFM) is widely used to assess fetal status in labor. Use of intrapartum continuous EFM is associated with a lower risk of neonatal seizures but a higher risk of cesarean or operative delivery. Category II fetal heart tracings (FHTs) are indeterminate in their ability to predict fetal acidemia. Certain patterns of decelerations and variability within this category may be predictive of neonatal morbidity. Adjunct tests of fetal well-being can be used during labor to further triage patients. Intrauterine resuscitation techniques should target the suspected etiology of intrapartum fetal hypoxia. Clinical factors play a role in the interpretation of EFM. Copyright © 2017 Elsevier Inc. All rights reserved.
What may cause fetus loss from acute pancreatitis in pregnancy: Analysis of 54 cases.
Tang, Min; Xu, Jian-Ming; Song, Sha-Sha; Mei, Qiao; Zhang, Li-Jiu
2018-02-01
Acute pancreatitis in pregnancy (APIP) poses a serious threat to the mother and her fetus, and might lead to fetal loss including miscarriage and stillbirth in certain patients. We sought to identify possible factors that affect fetal distress and evaluated outcomes of patients with APIP.We retrospectively reviewed clinical records of 54 pregnant women with APIP, who were treated at 2 tertiary clinical centers over a 6-year period. Clinical characteristics including etiology and severity of APIP, fetal monitoring data, and maternofetal outcomes were analyzed.Etiology of APIP included acute biliary pancreatitis (ABP, n = 14), hyperlipidemic pancreatitis (HLP, n = 22), and other etiologies (n = 18). Severity was classified as mild acute pancreatitis (MAP, n = 23), moderately severe acute pancreatitis (MSAP, n = 24), and severe acute pancreatitis (SAP, n = 7). The incidence of preterm delivery, fetal distress, and fetal loss increased with the progression of severity of APIP (P < .05). The severity of HLP was significantly higher than that of ABP and APIP of other etiology (P < .01). HLP was more likely to lead to fetal distress than other APs (P < .01). Only 12 (22.2%) patients had fetal monitoring including non-stress test (NST); 1 case of SAP (14.3%) and 15 cases of MSAP (62.5%) were not transferred to intensive care unit for intensive monitoring.The incidence of fetal distress and fetal loss increased with worsening of APIP severity. HLP tends to result in worse fetal outcomes. The deficiencies of fetal state monitoring, lack of assessment, and management of pregnant women might increase the fetal loss in APIP.
Special Tests for Monitoring Fetal Health
... a nonstress test? The nonstress test measures the fetal heart rate in response to fetal movement over time. The ... A belt with a sensor that measures the fetal heart rate is placed around your abdomen. The fetal heart ...
Electronic fetal monitoring: family medicine obstetrics.
Rodney, John R M; Huntley, Benjamin J F; Rodney, Wm Macmillan
2012-03-01
Electronic fetal monitoring assesses fetal health during the prenatal and intrapartum process. Intermittent auscultation does not detect key elements of fetal risk, such as beat-to-beat variability. Family medicine obstetric fellowships have contributed new knowledge to this process by articulating a method of analysis that builds on evidence-based recommendations from the American College of Obstetrics and Gynecology as well as the National Institute of Child Health and Development. This article summarizes the development, interpretation, and management of electronic fetal heart rate patterns and tracings. Copyright © 2012 Elsevier Inc. All rights reserved.
Management of Complex Cardiac Issues in the Pregnant Patient.
Hu, Huayong; Pasca, Ioana
2016-01-01
Management of peripartum heart disease in the intensive care unit requires optimization of maternal hemodynamics and maintenance of fetal perfusion. This requires fetal monitoring and should address the parturient's oxygen saturation, hemoglobin, and cardiac output as it relates to uterine blood flow. Pharmacologic strategies have limited evidence pertaining to hemodynamic stabilization and fetal perfusion. There is some evidence that surgical management of critical mitral stenosis should be percutaneous when possible because cardiac bypass is associated with increased fetal mortality. Fetal monitoring strategies should address central organ perfusion because peripheral scalp pH has not been associated with improved fetal outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.
RF Safety Analysis of a Novel Ultra-wideband Fetal Monitoring System.
Bushberg, Jerrold T; Tupin, J Paul
2017-05-01
The LifeWave Ultra-Wideband RF sensor (LWUWBS) is a monitoring solution for a variety of physiologic assessment applications, including maternal fetal monitoring in both the antepartum and intrapartum periods. The system uses extremely low power radio frequency (RF) ultra-wide band (UWB) signals to provide continuous fetal heart rate and contractions monitoring during labor and delivery. Even with the incorporation of three very conservative assumptions, (1) concentration of the RF energy in 1 cm, (2) minimal (2.5 cm) maternal tissue attenuation of fetal exposure, and (3) absence of normal thermoregulatory compensation, the maternal whole body spatial-averaged specific absorption rate (WBSAR) would be 34,000 times below the FCC public exposure limit of 0.08 W kg and, at 8 wk or more gestation, the peak spatial-averaged specific absorption rate (PSSAR) in the fetus would be more than 160 times below the localized exposure limit of 1.6 mW g. Even when using very conservative assumptions, an analysis of the LWUWBS's impact on tissue heating is a factor of 7 lower than what is allowed for fetal ultrasound and at least a factor of 650 compared to fetal MRI. The actual transmitted power levels of the LWUWBS are well below all Federal safety standards, and the potential for tissue heating is substantially lower than associated with current ultrasonic fetal monitors and MRI.
Frasch, Martin G; Keen, Ashley E; Gagnon, Robert; Ross, Michael G; Richardson, Bryan S
2011-01-01
Severe fetal acidemia during labour with arterial pH below 7.00 is associated with increased risk of hypoxic-ischemic brain injury. Electronic fetal heart rate (FHR) monitoring, the mainstay of intrapartum surveillance, has poor specificity for detecting fetal acidemia. We studied brain electrical activity measured with electrocorticogram (ECOG) in the near term ovine fetus subjected to repetitive umbilical cord occlusions (UCO) inducing FHR decelerations, as might be seen in human labour, to delineate the time-course for ECOG changes with worsening acidemia and thereby assess the potential clinical utility of fetal ECOG. Ten chronically catheterized fetal sheep were studied through a series of mild, moderate and severe UCO until the arterial pH was below 7.00. At a pH of 7.24 ± 0.04, 52 ± 13 min prior to the pH dropping <7.00, spectral edge frequency (SEF) increased to 23 ± 2 Hz from 3 ± 1 Hz during each FHR deceleration (p<0.001) and was correlated to decreases in FHR and in fetal arterial blood pressure during each FHR deceleration (p<0.001). The UCO-related changes in ECOG occurred in advance of the pH decreasing below 7.00. These ECOG changes may be a protective mechanism suppressing non-essential energy needs when oxygen supply to the fetal brain is decreased acutely. By detecting such "adaptive brain shutdown," the need for delivery in high risk pregnant patients may be more accurately predicted than with FHR monitoring alone. Therefore, monitoring fetal electroencephalogram (EEG, the human equivalent of ECOG) during human labour may be a useful adjunct to FHR monitoring.
Frasch, Martin G.; Keen, Ashley E.; Gagnon, Robert; Ross, Michael G.; Richardson, Bryan S.
2011-01-01
Background Severe fetal acidemia during labour with arterial pH below 7.00 is associated with increased risk of hypoxic-ischemic brain injury. Electronic fetal heart rate (FHR) monitoring, the mainstay of intrapartum surveillance, has poor specificity for detecting fetal acidemia. We studied brain electrical activity measured with electrocorticogram (ECOG) in the near term ovine fetus subjected to repetitive umbilical cord occlusions (UCO) inducing FHR decelerations, as might be seen in human labour, to delineate the time-course for ECOG changes with worsening acidemia and thereby assess the potential clinical utility of fetal ECOG. Methodology/Principal Findings Ten chronically catheterized fetal sheep were studied through a series of mild, moderate and severe UCO until the arterial pH was below 7.00. At a pH of 7.24±0.04, 52±13 min prior to the pH dropping <7.00, spectral edge frequency (SEF) increased to 23±2 Hz from 3±1 Hz during each FHR deceleration (p<0.001) and was correlated to decreases in FHR and in fetal arterial blood pressure during each FHR deceleration (p<0.001). Conclusions/Significance The UCO-related changes in ECOG occurred in advance of the pH decreasing below 7.00. These ECOG changes may be a protective mechanism suppressing non-essential energy needs when oxygen supply to the fetal brain is decreased acutely. By detecting such “adaptive brain shutdown,” the need for delivery in high risk pregnant patients may be more accurately predicted than with FHR monitoring alone. Therefore, monitoring fetal electroencephalogram (EEG, the human equivalent of ECOG) during human labour may be a useful adjunct to FHR monitoring. PMID:21789218
Wang, Qiming; Gold, Nathan; Frasch, Martin G; Huang, Huaxiong; Thiriet, Marc; Wang, Xiaogang
2015-12-01
Fetal acidemia during labor is associated with an increased risk of brain injury and lasting neurological deficits. This is in part due to the repetitive occlusions of the umbilical cord (UCO) induced by uterine contractions. Whereas fetal heart rate (FHR) monitoring is widely used clinically, it fails to detect fetal acidemia. Hence, new approaches are needed for early detection of fetal acidemia during labor. We built a mathematical model of the UCO effects on FHR, mean arterial blood pressure (MABP), oxygenation and metabolism. Mimicking fetal experiments, our in silico model reproduces salient features of experimentally observed fetal cardiovascular and metabolic behavior including FHR overshoot, gradual MABP decrease and mixed metabolic and respiratory acidemia during UCO. Combined with statistical analysis, our model provides valuable insight into the labor-like fetal distress and guidance for refining FHR monitoring algorithms to improve detection of fetal acidemia and cardiovascular decompensation.
Signal processing methodologies for an acoustic fetal heart rate monitor
NASA Technical Reports Server (NTRS)
Pretlow, Robert A., III; Stoughton, John W.
1992-01-01
Research and development is presented of real time signal processing methodologies for the detection of fetal heart tones within a noise-contaminated signal from a passive acoustic sensor. A linear predictor algorithm is utilized for detection of the heart tone event and additional processing derives heart rate. The linear predictor is adaptively 'trained' in a least mean square error sense on generic fetal heart tones recorded from patients. A real time monitor system is described which outputs to a strip chart recorder for plotting the time history of the fetal heart rate. The system is validated in the context of the fetal nonstress test. Comparisons are made with ultrasonic nonstress tests on a series of patients. Comparative data provides favorable indications of the feasibility of the acoustic monitor for clinical use.
Cahill, Alison G; Tuuli, Methodius G; Stout, Molly J; López, Julia D; Macones, George A
2018-05-01
Intrapartum electronic fetal monitoring is the most commonly used tool in obstetrics in the United States; however, which electronic fetal monitoring patterns predict acidemia remains unclear. This study was designed to describe the frequency of patterns seen in labor using modern nomenclature, and to test the hypothesis that visually interpreted patterns are associated with acidemia and morbidities in term infants. We further identified patterns prior to delivery, alone or in combination, predictive of acidemia and neonatal morbidity. This was a prospective cohort study of 8580 women from 2010 through 2015. Patients were all consecutive women laboring at ≥37 weeks' gestation with a singleton cephalic fetus. Electronic fetal monitoring patterns during the 120 minutes prior to delivery were interpreted in 10-minute epochs. Interpretation included the category system and individual electronic fetal monitoring patterns per the Eunice Kennedy Shriver National Institute of Child Health and Human Development criteria as well as novel patterns. The primary outcome was fetal acidemia (umbilical artery pH ≤7.10); neonatal morbidities were also assessed. Final regression models for acidemia adjusted for nulliparity, pregestational diabetes, and advanced maternal age. Area under the receiver operating characteristic curves were used to assess the test characteristics of individual models for acidemia and neonatal morbidity. Of 8580 women, 149 (1.7%) delivered acidemic infants. Composite neonatal morbidity was diagnosed in 757 (8.8%) neonates within the total cohort. Persistent category I, and 10-minute period of category III, were significantly associated with normal pH and acidemia, respectively. Total deceleration area was most discriminative of acidemia (area under the receiver operating characteristic curves, 0.76; 95% confidence interval, 0.72-0.80), and deceleration area with any 10 minutes of tachycardia had the greatest discriminative ability for neonatal morbidity (area under the receiver operating characteristic curves, 0.77; 95% confidence interval, 0.75-0.79). Once the threshold of deceleration area is reached the number of cesareans needed-to-be performed to potentially prevent 1 case of acidemia and morbidity is 5 and 6, respectively. Deceleration area is the most predictive electronic fetal monitoring pattern for acidemia, and combined with tachycardia for significant risk of morbidity, from the electronic fetal monitoring patterns studied. It is important to acknowledge that this study was performed in patients delivering ≥37 weeks, which may limit the generalizability to preterm populations. We also did not use computerized analysis of the electronic fetal monitoring patterns because human visual interpretation was the basis for the Eunice Kennedy Shriver National Institute of Child Health and Human Development categories, and importantly, it is how electronic fetal monitoring is used clinically. Copyright © 2018 Elsevier Inc. All rights reserved.
Prone position craniotomy in pregnancy without fetal heart rate monitoring.
Jacob, Jean; Alexander, Ashish; Philip, Shoba; Thomas, Anoop
2016-09-01
A pregnant patient in second trimester scheduled for posterior fossa craniotomy in prone position is a challenge for the anesthesiologist. Things to consider are physiological changes during pregnancy, non-obstetric surgery in pregnant patients, neuroanesthetic principles, effects of prone positioning, and need for fetal heart rate (FHR) monitoring. We have described the anesthetic management of this case and discussed intra-operative FHR monitoring including controversies about its role, indications, and various options available as per fetal gestational age. In our case we attempted intermittent intra-operative FHR monitoring to optimize maternal positioning and fetal oxygenation even though the fetus was pre-viable. However the attempt was abandoned due to practical difficulties with prone positioning. Patient made good neurological recovery following the procedure and delivered a healthy term baby 4 months later. Decisions regarding fetal monitoring should be individualized based on viability of the fetus and feasibility of emergency cesarean delivery. Good communication between a multidisciplinary team involving neurosurgeon, anesthesiologist, obstetrician, and neonatologist is important for a successful outcome for mother and fetus. We conclude that prone position neurosurgery can safely be carried out in a pregnant patient with pre-viable fetus without FHR monitoring. Copyright © 2016 Elsevier Inc. All rights reserved.
Signorini, Maria G; Fanelli, Andrea; Magenes, Giovanni
2014-01-01
Monitoring procedures are the basis to evaluate the clinical state of patients and to assess changes in their conditions, thus providing necessary interventions in time. Both these two objectives can be achieved by integrating technological development with methodological tools, thus allowing accurate classification and extraction of useful diagnostic information. The paper is focused on monitoring procedures applied to fetal heart rate variability (FHRV) signals, collected during pregnancy, in order to assess fetal well-being. The use of linear time and frequency techniques as well as the computation of non linear indices can contribute to enhancing the diagnostic power and reliability of fetal monitoring. The paper shows how advanced signal processing approaches can contribute to developing new diagnostic and classification indices. Their usefulness is evaluated by comparing two selected populations: normal fetuses and intra uterine growth restricted (IUGR) fetuses. Results show that the computation of different indices on FHRV signals, either linear and nonlinear, gives helpful indications to describe pathophysiological mechanisms involved in the cardiovascular and neural system controlling the fetal heart. As a further contribution, the paper briefly describes how the introduction of wearable systems for fetal ECG recording could provide new technological solutions improving the quality and usability of prenatal monitoring.
Skoczylas, Michał; Laudański, Tadeusz
2003-10-01
Cardiotocography has become the standard for fetal monitoring in labor. False-positive findings during electronic fetal heart rate monitoring may were not associated with neonatal acidemia. Because of the poor specificity of fetal heart rate monitoring in predicting fetal distress, new methods are being investigated as a way to improve the accuracy of assessing the infant's condition during labor. The aim of this study was to determinate the efficiency of fetal blood oxygen saturation (FSpO2) and computer analysis of the fetal heart rate (Co-CTG) in the late 1-st stage of labor as a prognostic factor of newborn acidemia. Total 62 subjects were studied. During labors and deliveries fetal oxygen saturation was continuously recorded, with use of Nellecor N-400 fetal pulse oximeter and continous CTG were performed by Hewlett Packard 50A. Transdermal fetal oxygen saturation measurements and CTG results obtained during the labors was analyzed using MONAKO system (ITAM Zabrze). The results were compared with the values of pH and base deficit in the umbilical artery measured just after delivery. The sensitivity, specificity, negative, positive predictive values and Youden factor based on FHR and FSpO2, for prognosis of neonatal acidosis were: 65%, 80%, 16%, 97.5% 60% and 0.135 respectively FHR; and 100%, 60%, 100%, 96.8% and 0.968 respectively FSpO2. 1. The examination of fetal blood oxygen saturation in the labor is a useful prognostic factor of the newborn outcome. 2. The best predictive value for intrapartum fetal asphyxia with metabolic acidosis was found when fetal pulse oximetry is added to cardiotocography.
Afors, Karolina; Chandraharan, Edwin
2011-01-01
The aim of intrapartum continuous electronic fetal monitoring using a cardiotocograph (CTG) is to identify a fetus exposed to intrapartum hypoxic insults so that timely and appropriate action could be instituted to improve perinatal outcome. Features observed on a CTG trace reflect the functioning of somatic and autonomic nervous systems and the fetal response to hypoxic or mechanical insults during labour. Although, National Guidelines on electronic fetal monitoring exist for term fetuses, there is paucity of recommendations based on scientific evidence for monitoring preterm fetuses during labour. Lack of evidence-based recommendations may pose a clinical dilemma as preterm births account for nearly 8% (1 in 13) live births in England and Wales. 93% of these preterm births occur after 28 weeks, 6% between 22-27 weeks, and 1% before 22 weeks. Physiological control of fetal heart rate and the resultant features observed on the CTG trace differs in the preterm fetus as compared to a fetus at term making interpretation difficult. This review describes the features of normal fetal heart rate patterns at different gestations and the physiological responses of a preterm fetus compared to a fetus at term. We have proposed an algorithm "ACUTE" to aid management.
Cypryk, Katarzyna; Bartyzel, Lukasz; Zurawska-Klis, Monika; Mlynarski, Wojciech; Szadkowska, Agnieszka; Wilczynski, Jan; Nowakowska, Dorota; Wozniak, Lucyna A; Fendler, Wojciech
2015-09-01
Much evidence has shown that pregnancies in women with preexisting diabetes are affected by an increased risk of maternal and fetal adverse outcomes, probably linked to poor glycemic control. Despite great progress in medical care, the rate of stillbirths remains much higher in diabetes patients than in the general population. Recent technological advances in the field of glucose monitoring and noninvasive fetal heart rate monitoring made it possible to observe the fetal-maternal dependencies in a continuous manner. Fourteen type 1 diabetes patients were involved into the study and fitted with a blinded continuous glucose monitoring (CGM) recorder. Fetal electrocardiogram data were recorded using the Monica AN24™ device (Monica Healthcare Ltd., Nottingham, United Kingdom), the recordings of which were matched with CGM data. Statistical analysis was performed using a generalized mixed-effect logistic regression to account for individual factors. The mean number of paired data points per patient was 254±106, representing an observation period of 21.2±8.8 h. Mean glycemia equaled 5.64±0.68 mmol/L, and mean fetal heart rate was 135±6 beats/min. Higher glycemia correlated with fetal heart rate (R=0.32; P<0.0001) and was associated with higher odds of the fetus developing small accelerations (odds ratio=1.05; 95% confidence interval, 1.00-1.10; P=0.04). Elevated maternal glycemia of mothers with diabetes is associated with accelerations of fetal heart rate.
Monitoring of fetal radiation exposure during pregnancy.
Chandra, Venita; Dorsey, Chelsea; Reed, Amy B; Shaw, Palma; Banghart, Dawn; Zhou, Wei
2013-09-01
One unique concern of vascular surgeons and trainees is radiation exposure associated with increased endovascular practice. The safety of childbearing is a particular worry for current and future women in vascular surgery. Little is known regarding actual fetal radiation exposure. This multi-institutional study aimed to evaluate the radiation dosages recorded on fetal dosimeter badges and compare them to external badges worn by the same cohort of women. All women who declared pregnancy with potential radiation exposure were required to wear two radiation monitors at each institution, one outside and the other inside the lead apron. Maternal (external) and fetal monitor dosimeter readings were analyzed. Maternal radiation exposures prior to, during, and postpregnancy were also assessed to determine any associated behavior modification. Eighty-one women declared pregnancy from 2008 to 2011 and 32 had regular radiation exposure during pregnancy. Maternal whole-body exposures ranged from 21-731 mrem. The average fetal dosimeter recordings for the cohort rounded to zero. Only two women had positive fetal dosimeter recordings; one had a single recording of 3 mrem and the other had a single recording of 7 mrem. There was no significant difference between maternal exposures prior to, during, and postpregnancy. Lack of knowledge of fetal radiation exposure has concerned many vascular surgeons, prompting them to wear double lead aprons during pregnancy, and perhaps prevented numerous other women from entering the field. Our study showed negligible radiation exposure on fetal monitoring suggesting that with the appropriate safety precautions, these concerns may be unwarranted. Published by Mosby, Inc.
Aortic isthmus and cardiac monitoring of the growth-restricted fetus.
Acharya, Ganesh; Tronnes, Ashlie; Rasanen, Juha
2011-03-01
Aortic isthmus acts as an arterial watershed between the cerebral and placental circulations, connecting 2 parallel fetal ventricular pumps. It plays a crucial role in the fetal circulatory dynamics. Information about aortic isthmus blood flow may improve the management of sick fetuses. However, perceived technical difficulties limit the clinical use of aortic isthmus Doppler for fetal hemodynamic monitoring. Changes in aortic isthmus blood flow pattern seem to reflect fetal cardiovascular status accurately and predict perinatal and long-term neurodevelopmental outcome in intrauterine growth restriction. This review evaluates the available scientific information and discusses the role of aortic isthmus in fetal circulation. Copyright © 2011 Elsevier Inc. All rights reserved.
Visser, G H A; Bilardo, C M; Derks, J B; Ferrazzi, E; Fratelli, N; Frusca, T; Ganzevoort, W; Lees, C C; Napolitano, R; Todros, T; Wolf, H; Hecher, K
2017-09-01
In the TRUFFLE (Trial of Randomized Umbilical and Fetal Flow in Europe) study on the outcome of early fetal growth restriction, women were allocated to one of three groups of indication for delivery according to the following monitoring strategies: (1) reduced fetal heart rate (FHR) short-term variation (STV) on cardiotocography (CTG); (2) early changes in fetal ductus venosus (DV) waveform (DV-p95); and (3) late changes in fetal DV waveform (DV-no-A). However, many infants per monitoring protocol were delivered because of safety-net criteria, for maternal or other fetal indications, or after 32 weeks of gestation when the protocol was no longer applied. The objective of the present posthoc subanalysis was to investigate the indications for delivery in relation to 2-year outcome in infants delivered before 32 weeks to further refine management proposals. We included all 310 cases of the TRUFFLE study with known outcome at 2 years' corrected age and seven fetal deaths, excluding seven cases with inevitable perinatal death. Data were analyzed according to the allocated fetal monitoring strategy in combination with the indication for delivery. Overall, only 32% of liveborn infants were delivered according to the specified monitoring parameter for indication for delivery; 38% were delivered because of safety-net criteria, 15% for other fetal reasons and 15% for maternal reasons. In the CTG-STV group, 51% of infants were delivered because of reduced STV. In the DV-p95 group, 34% of infants were delivered because of abnormal DV and, in the DV-no-A group, only 10% of infants were delivered accordingly. The majority of infants in the DV groups were delivered for the safety-net criterion of spontaneous decelerations in FHR. Two-year intact survival was highest in the DV groups combined compared with the CTG-STV group (P = 0.05 for live births only, P = 0.21 including fetal death), with no difference between DV groups. A poorer outcome in the CTG-STV group was restricted to infants delivered because of FHR decelerations in the safety-net subgroup. Infants delivered because of maternal reasons had the highest birth weight and a non-significantly higher intact survival. In this subanalysis of infants delivered before 32 weeks, the majority were delivered for reasons other than the allocated monitoring strategy indication. Since, in the DV group, CTG-STV criteria were used as a safety net but in the CTG-STV group, no DV safety-net criteria were applied, we speculate that the slightly poorer outcome in the CTG-STV group might be explained by the absence of DV data. The optimal timing of delivery of fetuses with early intrauterine growth restriction may therefore be best determined by monitoring them longitudinally, with both DV and CTG monitoring. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Putting intelligent structured intermittent auscultation (ISIA) into practice.
Maude, Robyn M; Skinner, Joan P; Foureur, Maralyn J
2016-06-01
Fetal monitoring guidelines recommend intermittent auscultation for the monitoring of fetal wellbeing during labour for low-risk women. However, these guidelines are not being translated into practice and low-risk women birthing in institutional maternity units are increasingly exposed to continuous cardiotocographic monitoring, both on admission to hospital and during labour. When continuous fetal monitoring becomes routinised, midwives and obstetricians lose practical skills around intermittent auscultation. To support clinical practice and decision-making around auscultation modality, the intelligent structured intermittent auscultation (ISIA) framework was developed. The purpose of this discussion paper is to describe the application of intelligent structured intermittent auscultation in practice. The intelligent structured intermittent auscultation decision-making framework is a knowledge translation tool that supports the implementation of evidence into practice around the use of intermittent auscultation for fetal heart monitoring for low-risk women during labour. An understanding of the physiology of the materno-utero-placental unit and control of the fetal heart underpin the development of the framework. Intelligent structured intermittent auscultation provides midwives with a robust means of demonstrating their critical thinking and clinical reasoning and supports their understanding of normal physiological birth. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
21 CFR 884.2685 - Fetal scalp clip electrode and applicator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal scalp clip electrode and applicator. 884...
21 CFR 884.2685 - Fetal scalp clip electrode and applicator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal scalp clip electrode and applicator. 884...
21 CFR 884.2685 - Fetal scalp clip electrode and applicator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal scalp clip electrode and applicator. 884...
21 CFR 884.2685 - Fetal scalp clip electrode and applicator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal scalp clip electrode and applicator. 884...
21 CFR 884.2685 - Fetal scalp clip electrode and applicator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Monitoring Devices § 884.2685 Fetal scalp clip electrode and applicator. (a) Identification. A fetal scalp clip electrode and applicator is a device designed to establish electrical contact between fetal skin... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal scalp clip electrode and applicator. 884...
Acoustically based fetal heart rate monitor
NASA Technical Reports Server (NTRS)
Baker, Donald A.; Zuckerwar, Allan J.
1991-01-01
The acoustically based fetal heart rate monitor permits an expectant mother to perform the fetal Non-Stress Test in her home. The potential market would include the one million U.S. pregnancies per year requiring this type of prenatal surveillance. The monitor uses polyvinylidene fluoride (PVF2) piezoelectric polymer film for the acoustic sensors, which are mounted in a seven-element array on a cummerbund. Evaluation of the sensor ouput signals utilizes a digital signal processor, which performs a linear prediction routine in real time. Clinical tests reveal that the acoustically based monitor provides Non-Stress Test records which are comparable to those obtained with a commercial ultrasonic transducer.
Lew, S; Hämäläinen, M S; Okada, Y
2017-12-01
To evaluate whether a full-coverage fetal-maternal scanner can noninvasively monitor ongoing electrophysiological activity of maternal and fetal organs. A simulation study was carried out for a scanner with an array of magnetic field sensors placed all around the torso from the chest to the hip within a horizontal magnetic shielding enclosure. The magnetic fields from internal organs and an external noise source were computed for a pregnant woman with a 35-week old fetus. Signal processing methods were used to reject the external and internal interferences, to visualize uterine activity, and to detect activity of fetal heart and brain. External interference was reduced by a factor of 1000, sufficient for detecting signals from internal organs when combined with passive and active shielding. The scanner rejects internal interferences better than partial-coverage arrays. It can be used to estimate currents around the uterus. It clearly detects spontaneous activity from the fetal heart and brain without averaging and weaker evoked brain activity at all fetal head positions after averaging. The simulated device will be able to monitor the ongoing activity of the fetal and maternal organs. This type of scanner may become a novel tool in fetal medicine. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
Feasibility of a fetal measurement electrode system
NASA Technical Reports Server (NTRS)
1977-01-01
Findings of the study are summarized and conclude that all monitoring requirements are not currently satisfied. An approach is presented to provide a multiparametric monitoring system through combinations of existing transducers. This monitoring system would be appropriate, not only for intrapartum monitoring, but also for neonatal and adult blood gas evaluations. A literature search was conducted to provide an insight into current state-of-the-art in fetal monitoring.
Fetal oxygenation measurement using wireless near infrared spectroscopy
NASA Astrophysics Data System (ADS)
Macnab, Andrew; Shadgan, Babak; Janssen, Patricia; Rurak, Dan
2012-03-01
Background: Fetal well-being is determined in large part by how well the placenta is able to supply oxygen and nutrients, but current technology is unable to directly measure how well a placenta functions. Near-infrared spectroscopy (NIRS) utilizes optical methods to measure tissue oxygenation. This pilot project evaluated the feasibility of NIRS for fetal monitoring through the maternal abdominal wall using a sheep model. Methods: A miniature wireless 2-wavelength NIRS device was placed on the abdominal skin over the placenta of a pregnant ewe whose fetus had been chronically catheterized to allow arterial sampling for measurement of arterial oxygen saturation. The NIRS device has 3-paired light emitting diodes and a single photodiode detector; allowing measurement of an index of tissue oxygen saturation (TSI%). Fetal limb TSI% values were compared before and during fetal breathing movements. Correlation was made during these events between arterial values and placental TSI% monitored continuously in real time. Results: Serial measurements were obtained in a single experiment. The correlation between transcutaneous NIRS derived TSI% and direct arterial oxygen saturation was very high (R2=0.86). Measures of fetal limb TSI% were declined after episodes of fetal breathing (P<0.005). Conclusions: This correlation suggests that NIRS is sensitive enough to detect changes in fetal tissue oxygenation noninvasively through the maternal abdominal wall in real-time in a sheep model. NIRS data confirmed that fetal breathing movements decrease arterial oxygen saturation in fetal lambs. If validated by further study this optical methodology could be applied as means of monitoring fetal wellbeing in humans.
Passive Fetal Heart Monitoring System
NASA Technical Reports Server (NTRS)
Bryant, Timothy D. (Inventor); Wynkoop, Mark W. (Inventor); Holloway, Nancy M. H. (Inventor); Zuckerwar, Allan J. (Inventor)
2004-01-01
A fetal heart monitoring system preferably comprising a backing plate having a generally concave front surface and a generally convex back surface, and at least one sensor element attached to the concave front surface for acquiring acoustic fetal heart signals produced by a fetus within a body. The sensor element has a shape that conforms to the generally concave back surface of the backing plate. In one embodiment, the at least one sensor element comprises an inner sensor, and a plurality of outer sensors surrounding the inner sensor. The fetal heart monitoring system can further comprise a web belt, and a web belt guide movably attached to the web belt. The web belt guide being is to the convex back surface of the backing plate.
Ultrasound transducer positioning aid for fetal heart rate monitoring.
Hamelmann, Paul; Kolen, Alex; Schmitt, Lars; Vullings, Rik; van Assen, Hans; Mischi, Massimo; Demi, Libertario; van Laar, Judith; Bergmans, Jan
2016-08-01
Fetal heart rate (fHR) monitoring is usually performed by Doppler ultrasound (US) techniques. For reliable fHR measurements it is required that the fetal heart is located within the US beam. In clinical practice, clinicians palpate the maternal abdomen to identify the fetal presentation and then the US transducer is fixated on the maternal abdomen where the best fHR signal can be obtained. Finding the optimal transducer position is done by listening to the strength of the Doppler audio output and relying on a signal quality indicator of the cardiotocographic (CTG) measurement system. Due to displacement of the US transducer or displacement of the fetal heart out of the US beam, the fHR signal may be lost. Therefore, it is often necessary that the obstetrician repeats the tedious procedure of US transducer positioning to avoid long periods of fHR signal loss. An intuitive US transducer positioning aid would be highly desirable to increase the work flow for the clinical staff. In this paper, the possibility to determine the fetal heart location with respect to the transducer by exploiting the received signal power in the transducer elements is shown. A commercially available US transducer used for fHR monitoring is connected to an US open platform, which allows individual driving of the elements and raw US data acquisition. Based on the power of the received Doppler signals in the transducer elements, the fetal heart location can be estimated. A beating fetal heart setup was designed and realized for validation. The experimental results show the feasibility of estimating the fetal heart location with the proposed method. This can be used to support clinicians in finding the optimal transducer position for fHR monitoring more easily.
Fetal electrocardiogram (ECG) for fetal monitoring during labour.
Neilson, James P
2015-12-21
Hypoxaemia during labour can alter the shape of the fetal electrocardiogram (ECG) waveform, notably the relation of the PR to RR intervals, and elevation or depression of the ST segment. Technical systems have therefore been developed to monitor the fetal ECG during labour as an adjunct to continuous electronic fetal heart rate monitoring with the aim of improving fetal outcome and minimising unnecessary obstetric interference. To compare the effects of analysis of fetal ECG waveforms during labour with alternative methods of fetal monitoring. The Cochrane Pregnancy and Childbirth Group's Trials Register (latest search 23 September 2015) and reference lists of retrieved studies. Randomised trials comparing fetal ECG waveform analysis with alternative methods of fetal monitoring during labour. One review author independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. One review author assessed the quality of the evidence using the GRADE approach. Seven trials (27,403 women) were included: six trials of ST waveform analysis (26,446 women) and one trial of PR interval analysis (957 women). The trials were generally at low risk of bias for most domains and the quality of evidence for ST waveform analysis trials was graded moderate to high. In comparison to continuous electronic fetal heart rate monitoring alone, the use of adjunctive ST waveform analysis made no obvious difference to primary outcomes: births by caesarean section (risk ratio (RR) 1.02, 95% confidence interval (CI) 0.96 to 1.08; six trials, 26,446 women; high quality evidence); the number of babies with severe metabolic acidosis at birth (cord arterial pH less than 7.05 and base deficit greater than 12 mmol/L) (average RR 0.72, 95% CI 0.43 to 1.20; six trials, 25,682 babies; moderate quality evidence); or babies with neonatal encephalopathy (RR 0.61, 95% CI 0.30 to 1.22; six trials, 26,410 babies; high quality evidence). There were, however, on average fewer fetal scalp samples taken during labour (average RR 0.61, 95% CI 0.41 to 0.91; four trials, 9671 babies; high quality evidence) although the findings were heterogeneous and there were no data from the largest trial (from the USA). There were marginally fewer operative vaginal births (RR 0.92, 95% CI 0.86 to 0.99; six trials, 26,446 women); but no obvious difference in the number of babies with low Apgar scores at five minutes or babies requiring neonatal intubation, or babies requiring admission to the special care unit (RR 0.96, 95% CI 0.89 to 1.04, six trials, 26,410 babies; high quality evidence). There was little evidence that monitoring by PR interval analysis conveyed any benefit of any sort. The modest benefits of fewer fetal scalp samplings during labour (in settings in which this procedure is performed) and fewer instrumental vaginal births have to be considered against the disadvantages of needing to use an internal scalp electrode, after membrane rupture, for ECG waveform recordings. We found little strong evidence that ST waveform analysis had an effect on the primary outcome measures in this systematic review.There was a lack of evidence showing that PR interval analysis improved any outcomes; and a larger future trial may possibly demonstrate beneficial effects.There is little information about the value of fetal ECG waveform monitoring in preterm fetuses in labour. Information about long-term development of the babies included in the trials would be valuable.
Monitoring the fetal heart rate variability during labor.
Moslem, B; Mohydeen, A; Bazzi, O
2015-08-01
In respect to the main goal of our ongoing work for estimating the heart rate variability (HRV) from fetal electrocardiogram (FECG) signals for monitoring the health of the fetus, we investigate in this paper the possibility of extracting the fetal heart rate variability (HRV) directly from the abdominal composite recordings. Our proposed approach is based on a combination of two techniques: Periodic Component Analysis (PiCA) and recursive least square (RLS) adaptive filtering. The Fetal HRV of the estimated FECG signal is compared to a reference value extracted from an FECG signal recorded by using a spiral electrode attached directly to the fetal scalp. The results obtained show that the fetal HRV can be directly evaluated from the abdominal composite recordings without the need of recording an external reference signal.
Rooijakkers, Michiel; Rabotti, Chiara; Bennebroek, Martijn; van Meerbergen, Jef; Mischi, Massimo
2011-01-01
Non-invasive fetal health monitoring during pregnancy has become increasingly important. Recent advances in signal processing technology have enabled fetal monitoring during pregnancy, using abdominal ECG recordings. Ubiquitous ambulatory monitoring for continuous fetal health measurement is however still unfeasible due to the computational complexity of noise robust solutions. In this paper an ECG R-peak detection algorithm for ambulatory R-peak detection is proposed, as part of a fetal ECG detection algorithm. The proposed algorithm is optimized to reduce computational complexity, while increasing the R-peak detection quality compared to existing R-peak detection schemes. Validation of the algorithm is performed on two manually annotated datasets, the MIT/BIH Arrhythmia database and an in-house abdominal database. Both R-peak detection quality and computational complexity are compared to state-of-the-art algorithms as described in the literature. With a detection error rate of 0.22% and 0.12% on the MIT/BIH Arrhythmia and in-house databases, respectively, the quality of the proposed algorithm is comparable to the best state-of-the-art algorithms, at a reduced computational complexity.
Kawagoe, Yasuyuki; Sameshima, Hiroshi; Ikenoue, Tsuyomu
2008-07-01
The authors show that pulse transit time and blood pressure are reciprocal in fetal goat models. They applied this technique in clinical settings to correlate changes in pulse transit time with fetal heart rate monitoring patterns and acid-base status. In 18 uncomplicated pregnancies, pulse transit time was obtained from electrocardiograms to pulse oximeter waveform and averaged during each baseline period, defined by the interpretation of fetal heart rate monitoring. According to a > 10% change from the control value, chronological changes were categorized into shortened, unchanged, and prolonged. Pulse transit time was available in 82% +/- 11% of the recordings. In 15 fetuses, 2 (13%) showed prolonged, 7 (47%) showed shortened, and 6 (40%) showed unchanged conditions. Comparisons of the shortened and unchanged categories revealed that severe variable deceleration was significantly increased, and half or more fetuses showed hypoxemia in the shortened category. Shortening of pulse transit time, theoretically indicating a hypertensive condition, was more frequently associated with severe variable decelerations, suggesting that the pulse transit time may supplement the interpretation of fetal heart rate monitoring.
21 CFR 884.2660 - Fetal ultrasonic monitor and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal ultrasonic monitor and accessories. 884.2660 Section 884.2660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... physiological condition or characteristic in a measured value over a period of time (e.g., perinatal monitoring...
[Design of Smart Care Tele-Monitoring System for Mother and Fetus].
Xi, Haiyan; Gan, Guanghui; Zhang, Huilian; Chen, Chaomin
2015-03-01
To study and design a maternal and fetal monitoring system based on the cloud computing and internet of things, which can monitor and take smart care of the mother and fetus in 24 h. Using a new kind of wireless fetal monitoring detector and a mobile phone, thus the doctor can keep touch with hospital through internet. The mobile terminal was developed on the Android system, which accepted the data of fetal heart rate and uterine contraction transmitted from the wireless detector, exchange information with the server and display the monitoring data and the doctor's advice in real-time. The mobile phone displayed the fetal heart rate line and uterine contraction line in real-time, recorded the fetus' grow process. It implemented the real-time communication between the doctor and the user, through wireless communication technology. The system removes the constraint of traditional telephone cable for users, while the users can get remote monitoring from the medical institutions at home or in the nearest community at any time, providing health and safety guarantee for mother and fetus.
[Disputes and history of fetal heart monitoring].
Dueñas-García, Omar Felipe; Díaz-Sotomayor, Maricela
2011-01-01
The concept of fetal heart monitoring to determine the fetal wellbeing state has been employed for almost 300 years, but in the last 50 years it has observed drastic changes due to the incorporation of the electronic devices that has started controversy since the moment of its description and point of start. The purpose of this article is to mention the key points and controversial moments in the history of the cardiotocography
Afors, Karolina; Chandraharan, Edwin
2011-01-01
The aim of intrapartum continuous electronic fetal monitoring using a cardiotocograph (CTG) is to identify a fetus exposed to intrapartum hypoxic insults so that timely and appropriate action could be instituted to improve perinatal outcome. Features observed on a CTG trace reflect the functioning of somatic and autonomic nervous systems and the fetal response to hypoxic or mechanical insults during labour. Although, National Guidelines on electronic fetal monitoring exist for term fetuses, there is paucity of recommendations based on scientific evidence for monitoring preterm fetuses during labour. Lack of evidence-based recommendations may pose a clinical dilemma as preterm births account for nearly 8% (1 in 13) live births in England and Wales. 93% of these preterm births occur after 28 weeks, 6% between 22–27 weeks, and 1% before 22 weeks. Physiological control of fetal heart rate and the resultant features observed on the CTG trace differs in the preterm fetus as compared to a fetus at term making interpretation difficult. This review describes the features of normal fetal heart rate patterns at different gestations and the physiological responses of a preterm fetus compared to a fetus at term. We have proposed an algorithm “ACUTE” to aid management. PMID:21922045
Becker, Jeroen H; Krikhaar, Anniek; Schuit, Ewoud; Mårtendal, Annika; Maršál, Karel; Kwee, Anneke; Visser, Gerard H A; Amer-Wåhlin, Isis
2015-02-01
To study the predictive value of biphasic ST-events for interventions for suspected fetal distress and adverse neonatal outcome, when using ST-analysis of the fetal electrocardiogram (FECG) for intrapartum fetal monitoring. Prospective cohort study. Three academic hospitals in Sweden. Women in labor with a high-risk singleton fetus in cephalic position beyond 36 weeks of gestation. In women in labor who were monitored with conventional cardiotocography, ST-waveform analysis was recorded and concealed. Traces with biphasic ST-events of the FECG (index) were compared with traces without biphasic events of the FECG. The ability of biphasic events to predict interventions for suspected fetal distress and adverse outcome was assessed using univariable and multivariable logistic regression analyses. Interventions for suspected fetal distress and adverse outcome (defined as presence of metabolic acidosis (i.e. umbilical cord pH <7.05 and base deficit in extracellular fluid >12 mmol), umbilical cord pH <7.00, 5-min Apgar score <7, admittance to neonatal intensive care unit or perinatal death). Although the presence of biphasic events of the FECG was associated with more interventions for fetal distress and an increased risk of adverse outcome compared with cases with no biphasic events, the presence of significant (i.e. intervention advised according to cardiotocography interpretation) biphasic events showed no independent association with interventions for fetal distress [odds ratio (OR) 1.71, 95% confidence interval (CI) 0.65-4.50] or adverse outcome (OR 1.96, 95% CI 0.74-5.24). The presence of significant biphasic events did not discriminate in the prediction of interventions for fetal distress or adverse outcome. Therefore, biphasic events in relation to ST-analysis monitoring during birth should be omitted if future studies confirm our findings. © 2014 Nordic Federation of Societies of Obstetrics and Gynecology.
Sutha, P; Jayanthi, V E
2017-12-08
Birth defect-related demise is mainly due to congenital heart defects. In the earlier stage of pregnancy, fetus problem can be identified by finding information about the fetus to avoid stillbirths. The gold standard used to monitor the health status of the fetus is by Cardiotachography(CTG), cannot be used for long durations and continuous monitoring. There is a need for continuous and long duration monitoring of fetal ECG signals to study the progressive health status of the fetus using portable devices. The non-invasive method of electrocardiogram recording is one of the best method used to diagnose fetal cardiac problem rather than the invasive methods.The monitoring of the fECG requires development of a miniaturized hardware and a efficient signal processing algorithms to extract the fECG embedded in the mother ECG. The paper discusses a prototype hardware developed to monitor and record the raw mother ECG signal containing the fECG and a signal processing algorithm to extract the fetal Electro Cardiogram signal. We have proposed two methods of signal processing, first is based on the Least Mean Square (LMS) Adaptive Noise Cancellation technique and the other method is based on the Wavelet Transformation technique. A prototype hardware was designed and developed to acquire the raw ECG signal containing the mother and fetal ECG and the signal processing techniques were used to eliminate the noises and extract the fetal ECG and the fetal Heart Rate Variability was studied. Both the methods were evaluated with the signal acquired from a fetal ECG simulator, from the Physionet database and that acquired from the subject. Both the methods are evaluated by finding heart rate and its variability, amplitude spectrum and mean value of extracted fetal ECG. Also the accuracy, sensitivity and positive predictive value are also determined for fetal QRS detection technique. In this paper adaptive filtering technique uses Sign-sign LMS algorithm and wavelet techniques with Daubechies wavelet, employed along with de noising techniques for the extraction of fetal Electrocardiogram.Both the methods are having good sensitivity and accuracy. In adaptive method the sensitivity is 96.83, accuracy 89.87, wavelet sensitivity is 95.97 and accuracy is 88.5. Additionally, time domain parameters from the plot of heart rate variability of mother and fetus are analyzed.
MacEachin, S Rachel; Lopez, Connie M; Powell, Kimberly J; Corbett, Nancy L
2009-01-01
Electronic fetal monitoring has historically been interpreted with wide variation between and within disciplines on the obstetric healthcare team. This leads to inconsistent decision making in response to tracing interpretation. To implement a multidisciplinary electronic fetal monitoring training program, utilizing the best evidence available, enabling standardization of fetal heart rate interpretation to promote patient safety. Local multidisciplinary expertise along with an outside consultant collaborated over a series of meetings to create a multimedia instructional electronic fetal monitoring training program. After production was complete, a series of conferences attended by nurses, certified nurse midwives, and physician champions, from each hospital, attended to learn how to facilitate training at their own perinatal units. All healthcare personnel across the Kaiser Permanente perinatal program were trained in NICHD nomenclature, emergency response, interpretation guidelines, and how to create local collaborative practice agreements. Metrics for program effectiveness were measured through program evaluations from attendees, the Safety Attitudes Questionnaire. Program evaluations rendered very positive scores from both physicians and clinicians. Comparing baseline to 4 years later, the perception of safety from the staff has increased over 10% in 5 out of the 6 factors analyzed. Active participation from all disciplines in this training series has highlighted the importance of teamwork and communication. The Fetal Heart Rate Collaborative Practice Project continues to evolve utilizing other educational modalities, such as online EFM education and unit-based interdisciplinary tracing reviews.
Monitoring fetal maturation—objectives, techniques and indices of autonomic function*
Hoyer, Dirk; Żebrowski, Jan; Cysarz, Dirk; Gonçalves, Hernâni; Pytlik, Adelina; Amorim-Costa, Célia; Bernardes, João; Ayres-de-Campos, Diogo; Witte, Otto W; Schleußner, Ekkehard; Stroux, Lisa; Redman, Christopher; Georgieva, Antoniya; Payne, Stephen; Clifford, Gari; Signorini, Maria G; Magenes, Giovanni; Andreotti, Fernando; Malberg, Hagen; Zaunseder, Sebastian; Lakhno, Igor; Schneider, Uwe
2017-01-01
Objective Monitoring the fetal behavior does not only have implications for acute care but also for identifying developmental disturbances that burden the entire later life. The concept, of ‘fetal programming’, also known as ‘developmental origins of adult disease hypothesis’, e.g. applies for cardiovascular, metabolic, hyperkinetic, cognitive disorders. Since the autonomic nervous system is involved in all of those systems, cardiac autonomic control may provide relevant functional diagnostic and prognostic information. Approach The fetal heart rate patterns (HRP) are one of the few functional signals in the prenatal period that relate to autonomic control and, therefore, is key to fetal autonomic assessment. The development of sensitive markers of fetal maturation and its disturbances requires the consideration of physiological fundamentals, recording technology and HRP parameters of autonomic control. Main Results Based on the ESGCO2016 special session on monitoring the fetal maturation we herein report the most recent results on: (i) functional fetal autonomic brain age score (fABAS), Recurrence Quantitative Analysis and Binary Symbolic Dynamics of complex HRP resolve specific maturation periods, (ii) magnetocardiography (MCG) based fABAS was validated for cardiotocography (CTG), (iii) 30 min recordings are sufficient for obtaining episodes of high variability, important for intrauterine growth restriction (IUGR) detection in handheld Doppler, (iv) novel parameters from PRSA to identify Intra IUGR fetuses, (v) evaluation of fetal electrocardiographic (ECG) recordings, (vi) correlation between maternal and fetal HRV is disturbed in pre-eclampsia. Significance The reported novel developments significantly extend the possibilities for the established CTG methodology. Novel HRP indices improve the accuracy of assessment due to their more appropriate consideration of complex autonomic processes across the recording technologies (CTG, handheld Doppler, MCG, ECG). The ultimate objective is their dissemination into routine practice and studies of fetal developmental disturbances with implications for programming of adult diseases. PMID:28186000
Fetal Monitoring: Creating a Culture of Safety With Informed Choice
Heelan, Lisa
2013-01-01
The dominant culture in labor and birth is the medical model, not the midwifery model of woman-centered care. Consensus among professional and governmental groups is that, based on the evidence, intermittent auscultation is safer to use in healthy women with uncomplicated pregnancies than electronic fetal monitoring (EFM). Barriers impact the laboring woman’s ability to give informed choice regarding fetal monitoring. Lack of informed choice denies a woman her right to be in control of her birth experience, and is in opposition to a woman’s right to autonomy and self-determination. PMID:24868127
ACR Appropriateness Criteria® growth disturbances - risk of intrauterine growth restriction.
Zelop, Carolyn M; Javitt, Marcia C; Glanc, Phyllis; Dubinsky, Theodore; Harisinghani, Mukesh G; Harris, Robert D; Khati, Nadia J; Mitchell, Donald G; Pandharipande, Pari V; Pannu, Harpreet K; Podrasky, Ann E; Shipp, Thomas D; Siegel, Cary Lynn; Simpson, Lynn; Wall, Darci J; Wong-You-Cheong, Jade J
2013-09-01
Fetal growth disturbances include fetuses at risk for intrauterine growth restriction. These fetuses may have an estimated fetal weight at less than the 10% or demonstrate a plateau of fetal growth with an estimated fetal growth greater than the 10%. Uteroplacental insufficiency may play a major role in the etiology of intrauterine growth restriction. Fetuses at risk for intrauterine fetal growth restriction are susceptible to the potential hostility of the intrauterine environment leading to fetal hypoxia and fetal acidosis. Fetal well-being can be assessed using biophysical profile, Doppler velocimetry, fetal heart rate monitoring, and fetal movement counting.Fetal growth disturbances include fetuses at risk for intrauterine growth restriction. These fetuses may have an estimated fetal weight at less than the 10% or demonstrate a plateau of fetal growth with an estimated fetal growth greater than the 10%. Uteroplacental insufficiency may play a major role in the etiology of intrauterine growth restriction. Fetuses at risk for intrauterine fetal growth restriction are susceptible to the potential hostility of the intrauterine environment leading to fetal hypoxia and fetal acidosis. Fetal well-being can be assessed using biophysical profile, Doppler velocimetry, fetal heart rate monitoring, and fetal movement counting.The ACR Appropriateness Criteria® are evidence-based guidelines for specific clinical conditions that are reviewed every two years by a multidisciplinary expert panel. The guideline development and review include an extensive analysis of current medical literature from peer reviewed journals and the application of a well-established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances where evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment.
Lakhno, Igor; Behar, Joachim A; Oster, Julien; Shulgin, Vyacheslav; Ostras, Oleksii; Andreotti, Fernando
2017-01-01
Complete atrioventricular block in fetuses is known to be mostly associated with autoimmune disease and can be irreversible if no steroids treatment is provided. Conventional methods used in clinical practice for diagnosing fetal arrhythmia are limited since they do not reflect the primary electrophysiological conduction processes that take place in the myocardium. The non-invasive fetal electrocardiogram has the potential to better support fetal arrhythmias diagnosis through the continuous analysis of the beat to beat variation of the fetal heart rate and morphological analysis of the PQRST complex. We present two retrospective case reports on which atrioventricular block diagnosis could have been supported by the non-invasive fetal electrocardiogram. The two cases comprised a 22-year-old pregnant woman with the gestational age of 31 weeks and a 25-year-old pregnant woman with the gestational age of 41 weeks. Both women were admitted to the Department of Maternal and Fetal Medicine at the Kyiv and Kharkiv municipal perinatal clinics. Patients were observed using standard fetal monitoring methods as well as the non-invasive fetal electrocardiogram. The non-invasive fetal electrocardiographic recordings were analyzed retrospectively, where it is possible to identify the presence of the atrioventricular block. This study demonstrates, for the first time, the feasibility of the non-invasive fetal electrocardiogram as a supplementary method to diagnose of the fetal atrioventricular block. Combined with current fetal monitoring techniques, non-invasive fetal electrocardiography could support clinical decisions.
Georgieva, Antoniya; Payne, Stephen J; Moulden, Mary; Redman, Christopher W G
2011-01-01
We applied computerized methods to assess the Electronic Fetal Monitoring (EFM) in labor. We analyzed retrospectively the last hour of EFM for 1,370 babies, delivered by emergency Cesarean sections before the onset of pushing (data collected at the John Radcliffe Hospital, Oxford, UK). There were two cohorts according to the reason for intervention: (a) fetal distress, n(1) = 524 and (b) failure to progress and/or malpresentation, n(2) = 846. The cohorts were compared in terms of classical EFM features (baseline, decelerations, variability and accelerations), computed by a dedicated Oxford system for automated analysis--OxSys. In addition, OxSys was employed to simulate current clinical guidelines for the classification of fetal monitoring, i.e. providing in real time a three-tier grading system of the EFM (normal, indeterminate, or abnormal). The computerized features and the simulated guidelines corresponded well to the clinical management and to the actual labor outcome (measured by umbilical arterial pH).
A portable fetal heart monitor and its adaption to the detection of certain prenatal abnormalities
NASA Technical Reports Server (NTRS)
Zahorian, Stephen A.
1994-01-01
There were three primary objectives for this task: (1) The investigation of the feasibility of making the fetal heart rate monitor portable, using a laptop computer; (2) Improvements in the signal processing for the monitor; and (3) Implementation of a real-time hardware software system. These tasks have been completed as discussed in the following section.
Feasibility of noninvasive fetal electrocardiographic monitoring in a clinical setting.
Arya, Bhawna; Govindan, Rathinaswamy; Krishnan, Anita; Duplessis, Adre; Donofrio, Mary T
2015-06-01
Cardiac rhythm is an essential component of fetal cardiac evaluation. The Monica AN24 is a fetal heart rate monitor that may provide a quick, inexpensive modality for obtaining a noninvasive fetal electrocardiogram (fECG) in a clinical setting. The fECG device has the ability to acquire fECG signals and allow calculation of fetal cardiac time intervals between 16- and 42-week gestational age (GA). We aimed to demonstrate the feasibility of fECG acquisition in a busy fetal cardiology clinic using the Monica fetal heart rate monitor. This is a prospective observational pilot study of fECG acquired from fetuses referred for fetal echocardiography. Recordings were performed for 5-15 min. Maternal signals were attenuated and fECG averaged. fECG and fetal cardiac time intervals (PR, QRS, RR, and QT) were evaluated by two cardiologists independently and inter-observer reliability was assessed using intraclass coefficient (ICC). Sixty fECGs were collected from 50 mothers (mean GA 28.1 ± 6.1). Adequate signal-averaged waveforms were obtained in 20 studies with 259 cardiac cycles. Waveforms could not be obtained between 26 and 30 weeks. Fetal cardiac time intervals were measured and were reproducible for PR (ICC = 0.89; CI 0.77-0.94), QRS (ICC = 0.79; CI 0.51-0.91), and RR (ICC = 0.77; CI 0.53-0.88). QT ICC was poor due to suboptimal T-wave tracings. Acquisition of fECG and measurement of fetal cardiac time intervals is feasible in a clinical setting between 19- and 42-week GA, though tracings are difficult to obtain, especially between 26 and 30 weeks. There was high reliability in fetal cardiac time intervals measurements, except for QT. The device may be useful for assessing atrioventricular/intraventricular conduction in fetuses from 20 to 26 and >30 weeks. Techniques to improve signal acquisition, namely T-wave amplification, are ongoing.
Secourgeon, J-F
2012-10-01
Electronic fetal monitoring during labor is the most commonly used method to evaluate the fetal status, but it remains exposed to some criticism. By comparison with intermittent auscultation and in the light of the results of the great studies in the last 30 years, it may be accused its failure to improve the neonatal outcome and its responsibility in the increase on operative deliveries. Actually, the electronic fetal monitoring is a tool whose effectiveness is linked to the accuracy of the analysis developed by the clinician. Studies on assessment of the tracing interpretation indicate that there is always a lack of quality, which may be improved through training programs. It also reveals the benefit of the fetal blood sampling to reduce operative deliveries and the generalization of this method, in addition to electronic fetal monitoring, is recommended by referral agencies. More generally, the continuous monitoring is only a part of the patient safety strategy in the labour ward and we are currently observing, in some European countries and in the United States, the development of training programs concerning the management of the adverse outcomes in obstetrics. The good performances related to the quality of care are demonstrated by the findings of the studies performed in the centers that have implemented an active training policy. In France, the professionals directly involved in the field of the perinatology should benefit from such educational programs that could be organized within the care networks under the authority of referral agencies. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Hindley, Carol; Thomson, Ann M.
2005-01-01
Abstract Objective To investigate midwives’ attitudes, values and beliefs on the use of intrapartum fetal monitoring. Design Qualitative, semi‐structured interviews Subjects and setting Fifty‐eight registered midwives in two hospitals in the North of England. Results In this paper two main themes are discussed, these are: informed choice, and the power of the midwife. Midwives favoured the application of informed choice and shared a unanimous consensus on the definition. However, the idealistic perception of informed choice, which included contemporary notions of empowerment and autonomy for women expressing an informed choice, was not reportedly translated into practice. Midwives had to implement informed choice on intrapartum fetal monitoring within a competing set of health service agendas, i.e. medically driven protocols and a political climate of actively managed childbearing. This resulted in the manipulation of information during the midwives’ interactions with women. This ultimately meant that the women often got the choice the midwives wanted them to have. Conclusions The information that a midwife imparts may consciously or subconsciously affect the woman's uptake and understanding of information. Therefore, the midwife has a powerful role to play in balancing the benefits and risk ratios applicable to fetal heart rate monitoring. However, a deeply ingrained pre‐occupation with technological methods of intrapartum fetal monitoring over many years has made it difficult for midwives to offer alternative forms of monitoring. This has placed limits on the facilitation of informed choice and autonomous decision making for women. PMID:16266418
Antenatal Testing – A Reevaluation
Signore, Caroline; Freeman, Roger K.; Spong, Catherine Y.
2009-01-01
In August 2007, the Eunice Kennedy Shriver National Institute of Child Health and Human Development, the National Institutes of Health Office of Rare Diseases, the American College of Obstetricians and Gynecologists, and the American Academy of Pediatrics cosponsored a 2-day workshop to reassess the body of evidence supporting antepartum assessment of fetal well-being, identify key gaps in the evidence, and formulate recommendations for further research. Participants included experts in obstetrics and fetal physiology, and representatives from relevant stakeholder groups and organizations. This article is a summary of the discussions at the workshop, including synopses of oral presentations on the epidemiology of stillbirth and fetal neurological injury, fetal physiology, techniques for antenatal monitoring, and maternal and fetal indications for monitoring. Finally, a synthesis of recommendations for further research compiled from three breakout workgroups is presented. PMID:19300336
Wilson, Bailey; Burt, Bryan; Baker, Byron; Clark, Steven L; Belfort, Michael; Gandhi, Manisha
2016-01-01
Spontaneous pneumothorax during pregnancy has potentially serious implications for the mother and fetus. When surgical correction is required, complex maternal physiologic alterations may significantly affect fetal well-being. A woman underwent thoracoscopic lung resection and pleurodesis at 29 weeks of gestation. At various points during the procedure, maternal hemodynamic and respiratory consequences of anesthetic and surgical management resulted in severe fetal heart rate (FHR) decelerations and bradycardia. In each instance, physiologic manipulations based on an understanding of the likely cause of fetal hypoxia allowed correction of the FHR abnormalities without delivery. Nonsurgical perinatal intervention based on FHR monitoring and analysis of the likely pathophysiologic abnormalities underlying fetal decelerations may allow the gravid woman to undergo complex procedures and continue the pregnancy.
Luttkus, A K; Friedmann, W; Homm-Luttkus, C; Dudenhausen, J W
1998-03-01
The purpose of this study was the correlation of fetal oxygen saturation values to various fetal heart rate patterns, as well as to oxygen saturation values obtained by fetal blood analysis. These objectives need to be evaluated from the perspective that two generations of fetal oxisensors have been used. Two different oxisensor systems (FS10: 660+890 nm and FS14: 735+890 nm) and a blinded pulse oximeter (type N400, Nellcor Puritan Bennett) were utilized to monitor 112 fetuses. All data, including oxygen saturation, fetal heart rate patterns, signal and contact quality were stored on a personal computer and evaluated after delivery. The following median fetal oxygen saturation values were obtained: during reassuring fetal heart rate sequences 54% with the oxisensor FS10 and 48% with the newer FS14 oxisensor, during intervals of variable decelerations 43% with the FS10 oxisensor and 40% with the FS14 oxisensor. These differences between values obtained during normal and abnormal fetal heart rate patterns are significant. Due to non-reassuring fetal heart rate patterns 81 fetal blood analyses were performed. The values of pulse oximetry were 9% higher (6% for the FS14) than those of spectrophotometry. Correlation of both methods was r=0.66 (0.74 for the FS14). In combination with fetal heart rate monitoring, fetal pulse oximetry promises a better differentiation between low and high risk heart rate patterns. Oxygen saturation values from intermittent fetal blood sampling reassure the clinician concerning the accuracy of this new method of intrapartum fetal surveillance and underline the increased quality of the new generation of oxisensor using light of a wavelength of 735 and 890 nm.
Abi-Nader, Khalil N; Mehta, Vedanta; Shaw, S W Steven; Bellamy, Tom; Smith, Neil; Millross, Laura; Laverick, Beth; Filippi, Elisa; Boyd, Michael; Peebles, Donald M; David, Anna L
2011-01-01
Remote telemetric monitoring of fetal haemodynamics in pregnant sheep would allow unrestricted animal movement, minimize suffering and distress, and improve animal welfare, while enhancing the quality of data collected. This may also be useful in clinical practice following fetal surgery. Using an open fetal surgical technique at approximately two-thirds of gestation, we implanted the catheter of a D70-PCTP haemodynamic telemetric device (Data Sciences International, Tilburg, The Netherlands) into the carotid artery of the fetal sheep (n = 4). The attached transmitter was secured to the posterior aspect of the maternal anterior abdominal wall. Two receivers, with a range of 1 m each, were sited in an 11 m² sheep enclosure to maximize animal freedom while allowing continuous monitoring of the ewe. The receivers were connected by cable to a nearby computer. In the first two procedures, both fetuses died eight and 12 days after surgery, and the catheter tip was observed to be lying in the bicarotid trunk. In the next two procedures the catheter tip was threaded further upstream from the insertion point, in an attempt to reach the fetal aorta, and both fetuses survived until the scheduled postmortem examination at the end of pregnancy. After catheter implantation, fetal blood pressure (BP) and heart rate (HR) were successfully recorded continuously for seven days and then hourly per day for a further three weeks. The fetal BP and HR values were in the normal range for healthy sheep fetuses.
21 CFR 884.2600 - Fetal cardiac monitor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ascertain fetal heart activity during pregnancy and labor. The device is designed to separate fetal heart signals from maternal heart signals by analyzing electrocardiographic signals (electrical potentials generated during contraction and relaxation of heart muscle) obtained from the maternal abdomen with...
21 CFR 884.2600 - Fetal cardiac monitor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... ascertain fetal heart activity during pregnancy and labor. The device is designed to separate fetal heart signals from maternal heart signals by analyzing electrocardiographic signals (electrical potentials generated during contraction and relaxation of heart muscle) obtained from the maternal abdomen with...
21 CFR 884.2600 - Fetal cardiac monitor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... ascertain fetal heart activity during pregnancy and labor. The device is designed to separate fetal heart signals from maternal heart signals by analyzing electrocardiographic signals (electrical potentials generated during contraction and relaxation of heart muscle) obtained from the maternal abdomen with...
21 CFR 884.2600 - Fetal cardiac monitor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... ascertain fetal heart activity during pregnancy and labor. The device is designed to separate fetal heart signals from maternal heart signals by analyzing electrocardiographic signals (electrical potentials generated during contraction and relaxation of heart muscle) obtained from the maternal abdomen with...
21 CFR 884.2600 - Fetal cardiac monitor.
Code of Federal Regulations, 2014 CFR
2014-04-01
... ascertain fetal heart activity during pregnancy and labor. The device is designed to separate fetal heart signals from maternal heart signals by analyzing electrocardiographic signals (electrical potentials generated during contraction and relaxation of heart muscle) obtained from the maternal abdomen with...
21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...
21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...
21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...
21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...
21 CFR 884.2640 - Fetal phonocardiographic monitor and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal phonocardiographic monitor and accessories. 884.2640 Section 884.2640 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... includes the following accessories: signal analysis and display equipment, patient and equipment supports...
Mishra, Manisha; Sawhney, Ravindra; Kumar, Anil; Bapna, Kumar Ramesh; Kohli, Vijay; Wasir, Harpreet; Trehan, Naresh
2014-01-01
The fetal death rate associated with cardiac surgery with cardiopulmonary bypass (CPB) is as high as 9.5-29%. We report continuous monitoring of fetal heart rate and umbilical artery flow-velocity waveforms by transvaginal ultrasonography and their analyses in relation to events of the CPB in two cases in second trimester of pregnancy undergoing mitral valve replacement. Our findings suggest that the transition of circulation from corporeal to extracorporeal is the most important event during surgery; the associated decrease in mean arterial pressure (MAP) at this stage potentially has deleterious effects on the fetus, which get aggravated with the use of vasopressors. We suggest careful management of CPB at this stage, which include partial controlled CPB at initiation and gradual transition to full CPB; this strategy maintains high MAP and avoids the use of vasopressors. Maternal and fetal monitoring can timely recognize the potential problems and provide window for the required treatment.
Development of a piezopolymer pressure sensor for a portable fetal heart rate monitor
NASA Technical Reports Server (NTRS)
Zuckerwar, A. J.; Pretlow, R. A.; Stoughton, J. W.; Baker, D. A.
1993-01-01
A piezopolymer pressure sensor has been developed for service in a portable fetal heart rate monitor, which will permit an expectant mother to perform the fetal nonstress test, a standard predelivery test, in her home. Several sensors are mounted in an array on a belt worn by the mother. The sensor design conforms to the distinctive features of the fetal heart tone, namely, the acoustic signature, frequency spectrum, signal amplitude, and localization. The components of a sensor serve to fulfill five functions: signal detection, acceleration cancellation, acoustical isolation, electrical shielding, and electrical isolation of the mother. A theoretical analysis of the sensor response yields a numerical value for the sensor sensitivity, which is compared to experiment in an in vitro sensor calibration. Finally, an in vivo test on patients within the last six weeks of term reveals that nonstress test recordings from the acoustic monitor compare well with those obtained from conventional ultrasound.
Clark, Steven L; Hamilton, Emily F; Garite, Thomas J; Timmins, Audra; Warrick, Philip A; Smith, Samuel
2017-02-01
Despite intensive efforts directed at initial training in fetal heart rate interpretation, continuing medical education, board certification/recertification, team training, and the development of specific protocols for the management of abnormal fetal heart rate patterns, the goals of consistently preventing hypoxia-induced fetal metabolic acidemia and neurologic injury remain elusive. The purpose of this study was to validate a recently published algorithm for the management of category II fetal heart rate tracings, to examine reasons for the birth of infants with significant metabolic acidemia despite the use of electronic fetal heart rate monitoring, and to examine critically the limits of electronic fetal heart rate monitoring in the prevention of neonatal metabolic acidemia. The potential performance of electronic fetal heart rate monitoring under ideal circumstances was evaluated in an outcomes-blinded examination fetal heart rate tracing of infants with metabolic acidemia at birth (base deficit, >12) and matched control infants (base deficit, <8) under the following conditions: (1) expert primary interpretation, (2) use of a published algorithm that was developed and endorsed by a large group of national experts, (3) assumption of a 30-minute period of evaluation for noncritical category II fetal heart rate tracings, followed by delivery within 30 minutes, (4) evaluation without the need to provide patient care simultaneously, and (5) comparison of results under these circumstances with those achieved in actual clinical practice. During the study period, 120 infants were identified with an arterial cord blood base deficit of >12 mM/L. Matched control infants were not demographically different from subjects. In actual practice, operative intervention on the basis of an abnormal fetal heart rate tracings occurred in 36 of 120 fetuses (30.0%) with metabolic acidemia. Based on expert, algorithm-assisted reviews, 55 of 120 patients with acidemia (45.8%) were judged to need operative intervention for abnormal fetal heart rate tracings. This difference was significant (P=.016). In infants who were born with a base deficit of >12 mM/L in which blinded, algorithm-assisted expert review indicated the need for operative delivery, the decision for delivery would have been made an average of 131 minutes before the actual delivery. The rate of expert intervention for fetal heart rate concerns in the nonacidemic control group (22/120; 18.3%) was similar to the actual intervention rate (23/120; 19.2%; P=1.0) Expert review did not mandate earlier delivery in 65 of 120 patients with metabolic acidemia. The primary features of these 65 cases included the occurrence of sentinel events with prolonged deceleration just before delivery, the rapid deterioration of nonemergent category II fetal heart rate tracings before realistic time frames for recognition and intervention, and the failure of recognized fetal heart rate patterns such as variability to identify metabolic acidemia. Expert, algorithm-assisted fetal heart rate interpretation has the potential to improve standard clinical performance by facilitating significantly earlier recognition of some tracings that are associated with metabolic acidemia without increasing the rate of operative intervention. However, this improvement is modest. Of infants who are born with metabolic acidemia, only approximately one-half potentially could be identified and have delivery expedited even under ideal circumstances, which are probably not realistic in current US practice. This represents the limits of electronic fetal heart rate monitoring performance. Additional technologies will be necessary if the goal of the prevention of neonatal metabolic acidemia is to be realized. Copyright © 2016 Elsevier Inc. All rights reserved.
Influence of carbon monoxide poisoning on the fetal heart monitor tracing: a report of 3 cases.
Towers, Craig V; Corcoran, Vincent A
2009-03-01
The diagnosis of carbon monoxide poisoning in the third trimester of pregnancy requires an index of suspicion, and the appearance of the fetal heart monitor tracing may help in this regard. Three cases of third-trimester acute carbon monoxide poisoning occurred. In each pregnancy, the fetal heart monitor tracing on admission was correlated with the maternal carboxyhemoglobin level, and how the pattern changed following the institution of therapy was analyzed. In all 3 cases, the initial fetal heart rate pattern demonstrated decreased variability with an elevated baseline and an absence of accelerations and decelerations. Within 45-90 minutes of treatment onset, the baseline fetal heart rate dropped by 20-40 beats per minute, the variability became moderate, and accelerations occurred. Absent accelerations with minimal variability, if caused by uteroplacental insufficiency, are usually preceded by recurrent decelerations. Absent accelerations with minimal variability in the absence of recurrent decelerations may suggest another cause, of which carbon monoxide intoxication can be added to the differential, especially since this disorder often has nonspecific clinical symptoms.
Bryson, Kate; Wilkinson, Chris; Kuah, Sabrina; Matthews, Geoff; Turnbull, Deborah
2017-12-29
Women's views are critical for informing the planning and delivery of maternity care services. ST segment analysis (STan) is a promising method to more accurately detect when unborn babies are at risk of brain damage or death during labour that is being trialled for the first time in Australia. This is the first study to examine women's views about STan monitoring in this context. Semi-structured interviews were conducted with pregnant women recruited across a range of clinical locations at the study hospital. The interviews included hypothetical scenarios to assess women's prospective views about STan monitoring (as an adjunct to cardiotocography, (CTG)) compared to the existing fetal monitoring method of CTG alone. This article describes findings from an inductive and descriptive thematic analysis. Most women preferred the existing fetal monitoring method compared to STan monitoring; women's decision-making was multifaceted. Analysis yielded four themes relating to women's views towards fetal monitoring in labour: a) risk and labour b) mobility in labour c) autonomy and choice in labour d) trust in maternity care providers. Findings suggest that women's views towards CTG and STan monitoring are multifaceted, and appear to be influenced by individual labour preferences and the information being received and understood. This underlies the importance of clear communication between maternity care providers and women about technology use in intrapartum care. This research is now being used to inform the implementation of the first properly powered Australian randomised trial comparing STan and CTG monitoring.
Kohl, T; Müller, A; Tchatcheva, K; Achenbach, S; Gembruch, U
2005-12-01
Because of insufficient imaging by maternal transabdominal fetal echocardiography (TAE) in a human fetus with aortic atresia, imperforate atrial septum and progressive cardiac failure, we assessed the feasibility of fetal transesophageal echocardiography (TEE) as a monitoring tool during fetal cardiac intervention at 24 + 6 weeks of gestation. Percutaneous fetoscopic intraesophageal deployment of the ultrasound catheter was achieved and did not result in any maternal or fetal complications. Fetal TEE permitted substantially clearer definition of fetal cardiac anatomy and intracardiac device manipulations than conventional maternal TAE. Despite the employment of various devices, no sufficiently large opening could be achieved within the atrial septum. Although the fetus tolerated the procedure remarkably well and satisfactory fetoplacental flow could be documented at the end of the procedure, the fetus died from progressive cardiac failure 3 days after the intervention. Fetoscopic TEE is feasible in the human fetus and permits substantially clearer definition of fetal cardiac anatomy and intracardiac manipulations than conventional maternal TAE. Based on the observation of spontaneous closure of multiple iatrogenic perforations of the atrial septum, specialized devices are required in order to improve the technical success rate of septoplasty methods and hence the survival odds of these high-risk patients.
Does the Use of Diagnostic Technology Reduce Fetal Mortality?
Grytten, Jostein; Skau, Irene; Sørensen, Rune; Eskild, Anne
2018-01-19
To examine the effect that the introduction of new diagnostic technology in obstetric care has had on fetal death. The Medical Birth Registry of Norway provided detailed medical information for approximately 1.2 million deliveries from 1967 to 1995. Information about diagnostic technology was collected directly from the maternity units, using a questionnaire. The data were analyzed using a hospital fixed-effects regression with fetal mortality as the outcome measure. The key independent variables were the introduction of ultrasound and electronic fetal monitoring at each maternity ward. Hospital-specific trends and risk factors of the mother were included as control variables. The richness of the data allowed us to perform several robustness tests. The introduction of ultrasound caused a significant drop in fetal mortality rate, while the introduction of electronic fetal monitoring had no effect on the rate. In the population as a whole, ultrasound contributed to a reduction in fetal deaths of nearly 20 percent. For post-term deliveries, the reduction was well over 50 percent. The introduction of ultrasound made a major contribution to the decline in fetal mortality at the end of the last century. © Health Research and Educational Trust.
Canine fetal heart rate: do accelerations or decelerations predict the parturition day in bitches?
Gil, E M U; Garcia, D A A; Giannico, A T; Froes, T R
2014-10-15
Ultrasonography is a safe and efficient technique for monitoring fetal development and viability. One of the most important and widely used parameters to verify fetal viability is the fetal heart rate (HR). In human medicine, the fetal HR normally oscillates during labor in transient accelerations and decelerations associated with uterine contractions. The present study investigated whether these variations also occur in canine fetuses and its relationship to parturition. A cohort study was conducted in 15 pregnant bitches undergoing two-dimensional high-resolution ultrasonographic examination during the 8th and 9th week of gestation. Fetal HR was assessed in M-mode for 5 minutes in each fetus in all bitches. In addition, the bitches were monitored for clinical signs of imminent parturition. Associations between the HR, antepartum time, and delivery characteristics were evaluated with a Poisson regression model. Fetal HR acceleration and deceleration occurred in canine fetuses and predicted the optimal time of parturition. These findings can help veterinarians and sonographers better understand this phenomenon in canine fetuses. Copyright © 2014 Elsevier Inc. All rights reserved.
2014-01-01
Background Research-informed fetal monitoring guidelines recommend intermittent auscultation (IA) for fetal heart monitoring for low-risk women. However, the use of cardiotocography (CTG) continues to dominate many institutional maternity settings. Methods A mixed methods intervention study with before and after measurement was undertaken in one secondary level health service to facilitate the implementation of an initiative to encourage the use of IA. The intervention initiative was a decision-making framework called Intelligent Structured Intermittent Auscultation (ISIA) introduced through an education session. Results Following the intervention, medical records review revealed an increase in the use of IA during labour represented by a relative change of 12%, with improved documentation of clinical findings from assessments, and a significant reduction in the risk of receiving an admission CTG (RR 0.75, 95% CI, 0.60 – 0.95, p = 0.016). Conclusion The ISIA informed decision-making framework transformed the practice of IA and provided a mechanism for knowledge translation that enabled midwives to implement evidence-based fetal heart monitoring for low risk women. PMID:24884597
Holland, Marium
2017-01-01
Background Cytarabine use during pregnancy carries a 5–7% risk of neonatal cytopenia. We report two cases of fetal myelosuppression following high-dose cytarabine administration for acute myeloid leukemia (AML). Case 1 A 36-year-old G9P6 diagnosed with AML at 21 weeks was monitored for fetal anemia weekly and growth monthly. At 33 weeks (after 2 cycles), BPP was 2/10 and MCA PSV was elevated at 1.51 MoM. Urgent cesarean section was performed. The infant had an initial pH of 6.78 and pancytopenia (hematocrit 13.3%, platelets 3 K/UL, and white blood cell count 2.0 K/UL). Initially transfusion dependent, the neonate had count recovery by 3 weeks. Case 2 A 30-year-old G4P3 with AML at 26 weeks was monitored for fetal anemia twice weekly and growth monthly. At 34 weeks (after cycle 1), she was admitted with neutropenic fever. The fetal MCA PSV was borderline at 1.48 MoM. It improved to 1.38 MoM at 35 weeks but the fetal tracing worsened. At delivery the fetus was found to have a hematocrit of 30%, but with normal platelet and WBC. The fetus did not require any transfusions. Conclusion Cytarabine use during pregnancy may cause neonatal myelosuppression. We recommend monitoring for fetal anemia with MCA Dopplers twice weekly. PMID:29075543
Signore, Caroline; Freeman, Roger K; Spong, Catherine Y
2009-03-01
In August 2007, the Eunice Kennedy Shriver National Institute of Child Health and Human Development, the National Institutes of Health Office of Rare Diseases, the American College of Obstetricians and Gynecologists, and the American Academy of Pediatrics cosponsored a 2-day workshop to reassess the body of evidence supporting antepartum assessment of fetal well-being, identify key gaps in the evidence, and formulate recommendations for further research. Participants included experts in obstetrics and fetal physiology and representatives from relevant stakeholder groups and organizations. This article is a summary of the discussions at the workshop, including synopses of oral presentations on the epidemiology of stillbirth and fetal neurological injury, fetal physiology, techniques for antenatal monitoring, and maternal and fetal indications for monitoring. Finally, a synthesis of recommendations for further research compiled from three breakout workgroups is presented.
Kim, Y; Gelehrter, S K; Fifer, C G; Lu, J C; Owens, G E; Berman, D R; Williams, J; Wilkinson, J E; Ives, K A; Xu, Z
2011-04-01
Currently available fetal intervention techniques rely on invasive procedures that carry inherent risks. A non-invasive technique for fetal intervention could potentially reduce the risk of fetal and obstetric complications. Pulsed cavitational ultrasound therapy (histotripsy) is an ablation technique that mechanically fractionates tissue at the focal region using extracorporeal ultrasound. In this study, we investigated the feasibility of using histotripsy as a non-invasive approach to fetal intervention in a sheep model. The experiments involved 11 gravid sheep at 102-129 days of gestation. Fetal kidney, liver, lung and heart were exposed to ultrasound pulses (< 10 µs) delivered by an external 1-MHz focused ultrasound transducer at a 0.2-1-kHz pulse-repetition rate and 10-16 MPa peak negative pressure. Procedures were monitored and guided by real-time ultrasound imaging. Treated organs were examined by gross and histological inspection for location and degree of tissue injury. Hyperechoic, cavitating bubble clouds were successfully generated in 19/31 (61%) treatment attempts in 27 fetal organs beneath up to 8 cm of overlying tissue and fetal bones. Histological assessment confirmed lesion locations and sizes corresponding to regions where cavitation was monitored, with no lesions found when cavitation was absent. Inability to generate cavitation was primarily associated with increased depth to target and obstructing structures such as fetal limbs. Extracorporeal histotripsy therapy successfully created targeted lesions in fetal sheep organs without significant damage to overlying structures. With further improvements, histotripsy may evolve into a viable technique for non-invasive fetal intervention procedures. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.
Hod, Moshe; Kerner, Ram
2003-01-01
Antepartum fetal surveillance is routinely used to assess the risk of fetal death in high-risk pregnancies. Traditionally, testing is performed in the hospital or outpatient clinic by trained medical staff. New equipment is now available that is easy to operate and can be used for self-monitoring of the fetal heart rate (FHR) in the home setting. The tracings are transmitted by modem to a referral center for immediate interpretation by a health provider. The aim of this review was to assess the current data on the application of this new technology with regard to feasibility, access to care, maternal and neonatal outcome, patient and physician satisfaction, and cost-effectiveness.
Sonography in Fetal Birth Weight Estimation
ERIC Educational Resources Information Center
Akinola, R. A.; Akinola, O. I.; Oyekan, O. O.
2009-01-01
The estimation of fetal birth weight is an important factor in the management of high risk pregnancies. The information and knowledge gained through this study, comparing a combination of various fetal parameters using computer assisted analysis, will help the obstetrician to screen the high risk pregnancies, monitor the growth and development,…
Silberstein, Tali; Sheiner, Eyal; Salem, Shimrit Yaniv; Hamou, Batel; Aricha, Barak; Baumfeld, Yael; Yohay, Zehava; Elharar, Debora; Idan, Inbal; Yohay, David
2017-02-01
To determine whether fetal heart rate (FHR) monitoring categories during the 1st and 2nd stage of labor can predict arterial cord pH <7.2. A case control study was conducted including 653 consecutive term deliveries (37 weeks gestation and above) that were divided according to fetal pH ≤ 7.2 (n = 315) and fetal pH > 7.2 (n = 338). Deliveries occurred during the year 2013 in tertiary medical center, where arterial cord pH is routinely taken after birth. Intrapartum FHR monitoring categorization was defined according to the ACOG committee guidelines by two obstetricians. Multivariable models were constructed to control for confounders. Variable decelerations, late decelerations and bradycardia during the 1st and 2nd stages of labor were significantly higher in group of deliveries ended in cord pH < 7.2 compared with group of deliveries ended in cord pH > 7.2. A significant association was observed between category 2 and 3 during the 1st stage of labor and pH ≤ 7.2. However, while controlling for FHR category 3 at the 2nd stage of labor, 1st stage categorization lost its association with pH <7.2, and only category 3 during the 2nd stage were noted as an independent risk factor for acidosis. FHR monitoring category 3 during the 2nd stage of labor is an independent predictor of fetal acidosis as expressed by arterial cord pH < 7.2.
Nurani, Raisha; Chandraharan, Edwin; Lowe, Virginia; Ugwumadu, Austin; Arulkumaran, Sabaratnam
2012-12-01
To identify the incidence of fetal heart rate (FHR) accelerations in the second stage of labor and the role of fetal electrocardiograph (ECG) in avoiding misidentification of maternal heart rate (MHR) as FHR. Retrospective observational study. University hospital labor ward, London, UK. Cardiotocograph (CTG) tracings of 100 fetuses monitored using external transducers and internal scalp electrodes. CTG traces that fulfilled inclusion criteria were selected from an electronic FHR monitoring database. Rate of accelerations during external and internal monitoring as well as decelerations for a period of 60 minutes prior to delivery were determined. The role of fetal ECG in differentiating between MHR and FHR trace was explored. Decelerations occurred in 89% of CTG traces during the second stage of labor. Accelerations indicating possible recording of FHR or MHR were found in 28.1 and 10.9% of cases recorded by an external ultrasound transducer as well as internal scalp electrode, respectively. Accelerations coinciding with uterine contractions occurred only in 11.7 and 4% of external and internal recording of FHR, respectively. Absence of 'p-wave' of the ECG waveform was associated with MHR trace. Decelerations were the commonest CTG feature during the second stage of labor. The incidence of accelerations coinciding with uterine contractions was less than half in fetuses monitored using a fetal scalp electrode. Analysing the ECG waveform for the absence of 'p-wave' helps in differentiating MHR from FHR. © 2012 The Authors Acta Obstetricia et Gynecologica Scandinavica© 2012 Nordic Federation of Societies of Obstetrics and Gynecology.
ERIC Educational Resources Information Center
Banta, H. David; Thacker, Stephen B.
This report focuses on electronic fetal monitoring (EFM)--a technology that was developed during the 1960s and has rapidly spread into use in clinical obstetrics. The report includes a review of the extensive published literature on EFM and related subjects. It also contains original calculations concerning the technique's specificity and…
Effect of uterine contractions on fetal heart rate in pregnancy: a prospective observational study.
Sletten, Julie; Kiserud, Torvid; Kessler, Jörg
2016-10-01
The new Holter monitoring technology enables long-term electrocardiographic recording of the fetal heart rate without discomfort for the mother. The aim of the study was to assess the feasibility of a fetal Holter monitor. This technology was further used to study fetal heart rate outside the hospital setting during normal daily activities and to test the hypothesis that uterine activity during pregnancy influences fetal heart rate. Prospective observational study including 12 healthy pregnant women at 20-40 weeks of gestation. Data were collected using the Monica AN24 system. Outcome measures were fetal heart rate, maternal heart rate, and uterine activity categorized according to the strength of the electrohysterographic signal. The recordings had a median length of 18.8 h, and fetal heart rate and maternal heart rate were obtained with success rates of 73.1 and 99.9%, respectively. Uterine activity was found to affect fetal heart rate in all participants. Compared with the basal tone and mild levels of uterine activity, moderate and strong levels of uterine activity were associated with increases in fetal heart rate of 4.0 and 5.7 beats/min, respectively. At night, the corresponding increases were 4.9 and 7.6 beats/min. Linear correlations were found between maternal heart rate and fetal heart rate in 11 of the 12 cases, with a mean coefficient beta of 0.189. Both maternal heart rate and fetal heart rate exhibited a diurnal pattern, with lower heart rates being recorded at night. Uterine activity during pregnancy is associated with a graded response in fetal heart rate and may represent a physiological challenge for the development and adaptation of the fetal cardiovascular system. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.
Passive fetal monitoring sensor
NASA Astrophysics Data System (ADS)
Zuckerwar, Allan J.; Hall, Earl T.; Baker, Donald A.; Bryant, Timothy D.
1992-08-01
An ambulatory, passive sensor for use in a fetal monitoring system is discussed. The invention is comprised of a piezoelectric polymer film, combined with a metallic mounting plate fastened to a belt, and electrically connected to a signal processing unit by means of a shielded cable. The purpose of the sensor is to receive pressure pulses emitted by a fetus inside an expectant mother. Additionally, the monitor will filter out pressure pulses arising from other sources, such as the maternal heart.
Passive fetal monitoring sensor
NASA Technical Reports Server (NTRS)
Zuckerwar, Allan J. (Inventor); Hall, Earl T. (Inventor); Baker, Donald A. (Inventor); Bryant, Timothy D. (Inventor)
1992-01-01
An ambulatory, passive sensor for use in a fetal monitoring system is discussed. The invention is comprised of a piezoelectric polymer film, combined with a metallic mounting plate fastened to a belt, and electrically connected to a signal processing unit by means of a shielded cable. The purpose of the sensor is to receive pressure pulses emitted by a fetus inside an expectant mother. Additionally, the monitor will filter out pressure pulses arising from other sources, such as the maternal heart.
Fetal acoustic stimulation test for early intrapartum fetal monitoring.
Goonewardene, M; Hanwellage, K
2011-03-01
The fetal acoustic stimulation test (FAST) is a simple cost effective screening test for antenatal fetal monitoring. The aim of the study was to evaluate the FAST as a screening test for early intrapartum fetal well being. An initial non stress test (NST) followed by a FAST using corometric model 146 was carried out in 486 participants in early labour with uncomplicated singleton pregnancies and > 32 weeks gestation. A repeat NST was recorded in the participants who had an initial non reactive NST. The results of the NST and FAST were compared with fetal outcome. Maternal perception of fetal movements after FAST, results of NST before and after FAST, and the babies' 5 minute APGAR scores were measured. Of the 486 participants 413 (85%) noticed fetal movements after FAST. Initial NST was non reactive in 203 (42%) but 149 (31%) became reactive after FAST. Compared to the NST, FAST had a better sensitivity (97% vs 62%, p < 0.001), specificity (100% vs 87%, p = 0.017), positive predictive value (100% vs 98%, p = 0.024), negative predictive value (79% vs 17%, p < 0.001) and accuracy (99%vs 64%, p < 0.001) in predicting 5 minute APGAR < 7 in the baby. FAST is a reliable screening test for assessing fetal well being in early labour. It complements the NST and is better than the NST alone.
Gonçalves, Hernâni; Fernandes, Diana; Pinto, Paula; Ayres-de-Campos, Diogo; Bernardes, João
2017-11-01
Male gender is considered a risk factor for several adverse perinatal outcomes. Fetal gender effect on fetal heart rate (FHR) has been subject of several studies with contradictory results. The importance of maternal heart rate (MHR) monitoring during labor has also been investigated, but less is known about the effect of fetal gender on MHR. The aim of this study is to simultaneously assess maternal and FHR variability during labor in relation with fetal gender. Simultaneous MHR and FHR recordings were obtained from 44 singleton term pregnancies during the last 2 hr of labor (H 1, H 2 ). Heart rate tracings were analyzed using linear (time- and frequency-domain) and nonlinear indices. Both linear and nonlinear components were considered in assessing FHR and MHR interaction, including cross-sample entropy (cross-SampEn). Mothers carrying male fetuses (n = 22) had significantly higher values for linear indices related with MHR average and variability and sympatho-vagal balance, while the opposite occurred in the high-frequency component and most nonlinear indices. Significant differences in FHR were only observed in H 1 with higher entropy values in female fetuses. Assessing the differences between FHR and MHR, statistically significant differences were obtained in most nonlinear indices between genders. A significantly higher cross-SampEn was observed in mothers carrying female fetuses (n = 22), denoting lower synchrony or similarity between MHR and FHR. The variability of MHR and the synchrony/similarity between MHR and FHR vary with respect to fetal gender during labor. These findings suggest that fetal gender needs to be taken into account when simultaneously monitoring MHR and FHR. © 2017 Wiley Periodicals, Inc.
Fetal optimization during maternal sepsis: relevance and response of the obstetric anesthesiologist.
Chau, Anthony; Tsen, Lawrence C
2014-06-01
In many labor and delivery units, the obstetric anesthesiologist is often responsible for managing and stabilizing the acutely septic parturient. The management of maternal sepsis has been summarized previously; this study will focus on the implications of maternal sepsis on the fetus, and ways to optimize fetal outcomes. Although the complex pathophysiology of sepsis is being better understood, the incidence of maternal severe sepsis and deaths continues to increase. The differential sensitivities of systemic and uterine vasculature to catecholamines during pregnancy and the role of fetal inflammatory responses have recently been further elucidated. Additional investigations on methods of fetal monitoring are needed to assist in early identification of the compromised fetus. Despite decades of research, management of a septic parturient and her fetus, including the most appropriate resuscitation fluids, vasopressors and hemodynamic monitoring systems to maximize maternal and fetal outcomes, remain controversial. In the setting of maternal sepsis, fetal optimization is frequently best accomplished by meeting maternal hemodynamic, oxygenization, and infection treatment goals. Understanding the circulatory and pathophysiologic changes that occur within the uteroplacental unit and fetus is essential to identifying and resolving potential conflicts between maternal and fetal management goals.
Anesthesia For In Utero Repair of Myelomeningocele
Ferschl, Marla; Ball, Robert; Lee, Hanmin; Rollins, Mark D.
2013-01-01
Recently published results suggest that prenatal repair of fetal myelomeningocele is a potentially preferable alternative when compared to postnatal repair. In this article, the pathology of myelomeningocele, unique physiologic considerations, perioperative anesthetic management, and ethical considerations of open fetal surgery for prenatal myelomeningocele repair are discussed. Open fetal surgeries have many unique anesthetic issues such as inducing profound uterine relaxation, vigilance for maternal or fetal blood loss, fetal monitoring, and possible fetal resuscitation. Postoperative management, including the requirement for postoperative tocolysis and maternal analgesia are also reviewed. The success of intrauterine myelomeningocele repair relies on a well-coordinated multidisciplinary approach. Fetal surgery is an important topic for anesthesiologists to understand, as the number of fetal procedures is likely to increase as new fetal treatment centers are opened across the United States. PMID:23508219
Recent advances in fetal near-infrared spectroscopy
NASA Astrophysics Data System (ADS)
D'Antona, Donato; Aldrich, Clive J.; O'Brien, Patrick; Lawrence, Sally; Delpy, David T.; Wyatt, John S.
1997-01-01
Fetal brain injury resulting from hypoxia and ischemia during labor remains an important cause of death and long- term disability. However, little is known about fetal brain oxygenation and hemodynamics. There are currently no satisfactory clinical techniques for fetal monitoring and there remains a need for a new method to assess brain oxygenation. Fetal near infrared spectroscopy (NIRS) is a new technique that allows noninvasive observation of changes in the cerebral concentrations of oxyhemoglobin and deoxyhemoglobin to be made during labor. A specially designed optical probe is inserted through the dilated cervix and placed against the fetal head. It is then possible to compare changes in NIRS data with other observations of fetal conditions, such as fetal heart rate and acid-base status.
Rauf, Zubair; O'Brien, Ediri; Stampalija, Tamara; Ilioniu, Florin P; Lavender, Tina; Alfirevic, Zarko
2011-01-01
To evaluate the feasibility of continuous telemetric trans-abdominal fetal electrocardiogram (a-fECG) in women undergoing labour induction at home. Low risk women with singleton term pregnancy undergoing labour induction with retrievable, slow-release dinoprostone pessaries (n = 70) were allowed home for up to 24 hours, while a-fECG and uterine activity were monitored in hospital via wireless technology. Semi-structured diaries were analysed using a combined descriptive and interpretive approach. 62/70 women (89%) had successful home monitoring; 8 women (11%) were recalled because of signal loss. Home monitoring lasted between 2-22 hours (median 10 hours). Good quality signal was achieved most of the time (86%, SD 10%). 3 women were recalled back to hospital for suspicious a-fECG. In 2 cases suspicious a-fECG persisted, requiring Caesarean section after recall to hospital. 48/51 women who returned the diary coped well (94%); 46/51 were satisfied with home monitoring (90%). Continuous telemetric trans-abdominal fetal ECG monitoring of ambulatory women undergoing labour induction is feasible and acceptable to women.
Implantable ultra-low pulmonary pressure monitoring system for fetal surgery.
Etemadi, Mozziyar; Heller, J Alex; Schecter, Samuel C; Shue, Eveline H; Miniati, Doug; Roy, Shuvo
2012-11-01
Congenital pulmonary hypoplasia is a devastating condition affecting fetal and newborn pulmonary physiology, resulting in great morbidity and mortality. The fetal lung develops in a fluid-filled environment. In this work, we describe a novel, implantable pressure sensing and recording device which we use to study the pressures present in the fetal pulmonary tree throughout gestation. The system achieves 0.18 cm H2O resolution and can record for twenty one days continuously at 256 Hz. Sample tracings of in vivo fetal lamb recordings are shown.
Electronic fetal monitoring: a Canadian survey.
Davies, B L; Niday, P A; Nimrod, C A; Drake, E R; Sprague, A E; Trépanier, M J
1993-01-01
OBJECTIVES: To determine the current status of electronic fetal monitoring (EFM) in Canadian teaching and nonteaching hospitals, to review the medical and nursing standards of practice for EFM and to determine the availability of EFM educational programs. DESIGN: National survey in 1989. PARTICIPANTS: The directors of nursing at the 737 hospitals providing obstetric care were sent a questionnaire and asked to have it completed by the most appropriate staff member. The response rate was 80.5% (593/737); 44 hospitals did not have deliveries in 1988 and were excluded. The remaining hospitals varied in size from 8 to 1800 (mean 162.1) beds and had 1 to 7500 (mean 617.1) births in 1988; 18.8% were teaching hospitals. RESULTS: Of the 549 hospitals 419 (76.3%) reported having at least 1 monitor (range 1 to 30; mean 2.6); the mean number of monitors per hospital was higher in the teaching hospitals than in the nonteaching hospitals (6.2 v. 1.7). Manitoba had the lowest mean number of monitors per hospital (1.1) and Ontario the highest (3.7). In 71.8% of the hospitals with monitors almost all of the obstetric patients were monitored at some point during labour. However, 21.6% of the hospitals with monitors had no policy on EFM practice. The availability of EFM educational programs for physicians and nurses varied according to hospital size, type and region. CONCLUSIONS: Most Canadian hospitals providing obstetric services have electronic fetal monitors and use them frequently. Although substantial research has questioned the benefits of EFM, further definitive research is required. In the meantime, a national committee should be established to develop multidisciplinary guidelines for intrapartum fetal assessment. PMID:8485677
Adaptive shut-down of EEG activity predicts critical acidemia in the near-term ovine fetus.
Frasch, Martin G; Durosier, Lucien Daniel; Gold, Nathan; Cao, Mingju; Matushewski, Brad; Keenliside, Lynn; Louzoun, Yoram; Ross, Michael G; Richardson, Bryan S
2015-07-01
In fetal sheep, the electrocorticogram (ECOG) recorded directly from the cortex during repetitive heart rate (FHR) decelerations induced by umbilical cord occlusions (UCO) predictably correlates with worsening hypoxic-acidemia. In human fetal monitoring during labor, the equivalent electroencephalogram (EEG) can be recorded noninvasively from the scalp. We tested the hypothesis that combined fetal EEG - FHR monitoring allows for early detection of worsening hypoxic-acidemia similar to that shown for ECOG-FHR monitoring. Near-term fetal sheep (n = 9) were chronically instrumented with arterial and venous catheters, ECG, ECOG, and EEG electrodes and umbilical cord occluder, followed by 4 days of recovery. Repetitive UCOs of 1 min duration and increasing strength (with regard to the degree of reduction in umbilical blood flow) were induced each 2.5 min until pH dropped to <7.00. Repetitive UCOs led to marked acidosis (arterial pH 7.35 ± 0.01 to 7.00 ± 0.03). At pH of 7.22 ± 0.03 (range 7.32-7.07), and 45 ± 9 min (range 1 h 33 min-20 min) prior to attaining pH < 7.00, both ECOG and EEG amplitudes began to decrease ~fourfold during each FHR deceleration in a synchronized manner. Confirming our hypothesis, these findings support fetal EEG as a useful adjunct to FHR monitoring during human labor for early detection of incipient fetal acidemia. © 2015 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.
Boatin, Adeline A; Wylie, Blair; Goldfarb, Ilona; Azevedo, Robin; Pittel, Elena; Ng, Courtney; Haberer, Jessica
2015-01-01
We tested functionality and acceptability of a wireless fetal monitoring prototype technology in pregnant women in an inpatient labor unit in the United States. Women with full-term singleton pregnancies and no evidence of active labor were asked to wear the prototype technology for 30 minutes. We assessed functionality by evaluating the ability to successfully monitor the fetal heartbeat for 30 minutes, transmit this data to Cloud storage and view the data on a web portal. Three obstetricians also rated fetal cardiotocographs on ease of readability. We assessed acceptability by administering closed and open-ended questions on perceived utility and likeability to pregnant women and clinicians interacting with the prototype technology. Thirty-two women were enrolled, 28 of whom (87.5%) successfully completed 30 minutes of fetal monitoring including transmission of cardiotocographs to the web portal. Four sessions though completed, were not successfully uploaded to the Cloud storage. Six non-study clinicians interacted with the prototype technology. The primary technical problem observed was a delay in data transmission between the prototype and the web portal, which ranged from 2 to 209 minutes. Delays were ascribed to Wi-Fi connectivity problems. Recorded cardiotocographs received a mean score of 4.2/5 (± 1.0) on ease of readability with an interclass correlation of 0.81(95%CI 0.45, 0.96). Both pregnant women and clinicians found the prototype technology likable (81.3% and 66.7% respectively), useful (96.9% and 66.7% respectively), and would either use it again or recommend its use to another pregnant woman (77.4% and 66.7% respectively). In this pilot study we found that this wireless fetal monitoring prototype technology has potential for use in a United States inpatient setting but would benefit from some technology changes. We found it to be acceptable to both pregnant women and clinicians. Further research is needed to assess feasibility of using this technology in busy inpatient settings.
Journey to the Center of the Fetal Brain: Environmental Exposures and Autophagy.
Lei, Jun; Calvo, Pilar; Vigh, Richard; Burd, Irina
2018-01-01
Fetal brain development is known to be affected by adverse environmental exposures during pregnancy, including infection, inflammation, hypoxia, alcohol, starvation, and toxins. These exposures are thought to alter autophagy activity in the fetal brain, leading to adverse perinatal outcomes, such as cognitive and sensorimotor deficits. This review introduces the physiologic autophagy pathways in the fetal brain. Next, methods to detect and monitor fetal brain autophagy activity are outlined. An additional discussion explores possible mechanisms by which environmental exposures during pregnancy alter fetal brain autophagy activity. In the final section, a correlation of fetal autophagy activity with the observed postnatal phenotype is attempted. Our main purpose is to provide the current understanding or a lack thereof mechanisms on autophagy, underlying the fetal brain injury exposed to environmental insults.
NASA Astrophysics Data System (ADS)
Ribes, S.; Voicu, I.; Girault, J. M.; Fournier, M.; Perrotin, F.; Tranquart, F.; Kouamé, D.
2011-03-01
Electronic fetal monitoring may be required during the whole pregnancy to closely monitor specific fetal and maternal disorders. Currently used methods suffer from many limitations and are not sufficient to evaluate fetal asphyxia. Fetal activity parameters such as movements, heart rate and associated parameters are essential indicators of the fetus well being, and no current device gives a simultaneous and sufficient estimation of all these parameters to evaluate the fetus well-being. We built for this purpose, a multi-transducer-multi-gate Doppler system and developed dedicated signal processing techniques for fetal activity parameter extraction in order to investigate fetus's asphyxia or well-being through fetal activity parameters. To reach this goal, this paper shows preliminary feasibility of separating normal and compromised fetuses using our system. To do so, data set consisting of two groups of fetal signals (normal and compromised) has been established and provided by physicians. From estimated parameters an instantaneous Manning-like score, referred to as ultrasonic score was introduced and was used together with movements, heart rate and associated parameters in a classification process using Support Vector Machines (SVM) method. The influence of the fetal activity parameters and the performance of the SVM were evaluated using the computation of sensibility, specificity, percentage of support vectors and total classification accuracy. We showed our ability to separate the data into two sets : normal fetuses and compromised fetuses and obtained an excellent matching with the clinical classification performed by physician.
Prediction of fetal compromise in labor.
Prior, Tomas; Mullins, Edward; Bennett, Phillip; Kumar, Sailesh
2014-06-01
The majority of intrapartum fetal hypoxia occurs in uncomplicated pregnancies. Current intrapartum monitoring techniques have not resulted in a reduction in the incidence of cerebral palsy in term neonates. We report the development of a composite risk score to allow risk stratification of normal pregnancies before labor. Six hundred one women were recruited to this prospective observational study. All women underwent an ultrasound examination before active labor, during which fetal biometry and fetal Doppler flow resistance indices were measured. A composite risk score, amalgamating data from the umbilical artery, middle cerebral artery, and umbilical vein, was then developed and correlated with intrapartum outcomes. In cases with the highest composite risk scores, the incidence of fetal compromise (the primary outcome) was 80.0% compared with just 15.3% in cases with the lowest risk scores (relative risk 5.2, 95% confidence interval 2.7-10.1). These cases were also at increased risk of cesarean delivery (53.3% compared with 3.4%, P<.001) and of developing a fetal heart rate pattern considered pathologic by National Institute for Health and Clinical Excellence criteria (P=.003). No significant variation in Apgar scores or umbilical artery pH was observed. Intrapartum fetal compromise remains a significant global health issue. The composite risk score reported here can identify fetuses at both high risk and low risk of a subsequent diagnosis of intrapartum fetal compromise. This may enable more judicious use of current intrapartum fetal monitoring techniques, which are hampered by low specificity. II.
Integrating a Hand Held computer and Stethoscope into a Fetal Monitor
Ahmad Soltani, Mitra
2009-01-01
This article presents procedures for modifying a hand held computer or personal digital assistant (PDA) into a versatile device functioning as an electronic stethoscope for fetal monitoring. Along with functioning as an electronic stethoscope, a PDA can provide a useful information source for a medical trainee. Feedback from medical students, residents and interns suggests the device is well accepted by medical trainees. PMID:20165517
1988-07-05
ONITOR FETAL 10952.72 651501C725660 I MNrITOR OXYGEN 783.92 651501C725692 I PLMP BREAST MECHANICAL 1106.39 651501C725694 I STETHOSCOPE ULTRASOJ’D...TODDLEP 1496.12 651501C725969 I MONITOR, PHYSIOLOGICAL SYST, EMSS 2258.21 651501C726026 I FETAL HEART MCONITOR 9937.20 651501C726162 I OXI ETER, PULSE...THERMWTER FARE-EIT ELECTRONIC W/-ARGER 303.55 651501C725211 I MONITOR FETAL PULSE 1305.42 651501C725442 2 PUMP INFUSION VOLLUETRIC 1834.71 65150IC725596 I
The delivery room of the future: the fetal and neonatal resuscitation and transition suite.
Finer, Neil N; Rich, Wade; Halamek, Louis P; Leone, Tina A
2012-12-01
Despite advances in the understanding of fetal and neonatal physiology and the technology to monitor and treat premature and full-term neonates, little has changed in resuscitation rooms. The authors' vision for the Fetal and Neonatal Resuscitation and Transition Suite of the future is marked by improvements in the amount of physical space, monitoring technologies, portable diagnostic and therapeutic technologies, communication systems, and capabilities and training of the resuscitation team. Human factors analysis will play an important role in the design and testing of the improvements for safe, effective, and efficient resuscitation of the newborn. Copyright © 2012 Elsevier Inc. All rights reserved.
Robust estimation of fetal heart rate from US Doppler signals
NASA Astrophysics Data System (ADS)
Voicu, Iulian; Girault, Jean-Marc; Roussel, Catherine; Decock, Aliette; Kouame, Denis
2010-01-01
Introduction: In utero, Monitoring of fetal wellbeing or suffering is today an open challenge, due to the high number of clinical parameters to be considered. An automatic monitoring of fetal activity, dedicated for quantifying fetal wellbeing, becomes necessary. For this purpose and in a view to supply an alternative for the Manning test, we used an ultrasound multitransducer multigate Doppler system. One important issue (and first step in our investigation) is the accurate estimation of fetal heart rate (FHR). An estimation of the FHR is obtained by evaluating the autocorrelation function of the Doppler signals for ills and healthiness foetus. However, this estimator is not enough robust since about 20% of FHR are not detected in comparison to a reference system. These non detections are principally due to the fact that the Doppler signal generated by the fetal moving is strongly disturbed by the presence of others several Doppler sources (mother' s moving, pseudo breathing, etc.). By modifying the existing method (autocorrelation method) and by proposing new time and frequency estimators used in the audio' s domain, we reduce to 5% the probability of non-detection of the fetal heart rate. These results are really encouraging and they enable us to plan the use of automatic classification techniques in order to discriminate between healthy and in suffering foetus.
Yohai, David; Baumfeld, Yael; Zilberstein, Tali; Yaniv Salem, Shimrit; Elharar, Debbie; Idan, Inbal; Mastrolia, Salvatore Andrea; Sheiner, Eyal
2017-01-01
To investigate fetal gender and its influences on neonatal outcomes, taking into consideration the available tools for the assessment of fetal well-being. We conducted a retrospective study comparing maternal, fetal and neonatal outcomes according to fetal gender, in women carrying a singleton gestation. A multivariate analysis was performed for the prediction of adverse neonatal outcomes according to fetal gender, after adjustment for gestational age, maternal age and fetal weight. A total of 682 pregnancies were included in the study, of them 56% (n = 383) were carrying a male fetus and 44% (n = 299) a females fetus. Male gender was associated with a significant higher rate of abnormal fetal heart tracing patterns during the first (67.7% versus 55.1, p = 0.001) and the second stage (77.6 versus 67.7, p = 0.01) of labor. Male gender was also significantly associated with lower Apgar scores at 1' (19.1% versus 10.7%, p < 0.01), as well as lower pH values (7.18 ± 0.15 versus 7.23 ± 0.18, p < 0.001), and significant differences in cord blood components (PCO 2 , PO 2 ) compared with female fetuses. In the multivariate analysis, male gender was found to be significantly associated with first (OR 1.76, 95% CI 1.28-2.43, p = 0.001) and second stage (OR 1.73, 95% CI 1.20-2.50, p < 0.01) pathological fetal heart tracing patterns, pH < 7.1, and for Apgar scores at 1'< 7. The present study confirms the general trend of a lower clinical performance of male neonates compared with females. In addition, the relation between fetal heart rate patterns during all stages of labor and fetal gender showed an independent association between male fetal gender and abnormal fetal heart monitoring during labor.
Commercialization and Industrial Development for the Fetal Hear Rate Monitor
NASA Technical Reports Server (NTRS)
Zahorian, Stephen
2000-01-01
The primary objectives for this task were to continue the development and testing of the NASA/ODU passive acoustic fetal heart rate monitor, with the goal of transferring the technology to the commercial sector. Areas of work included: 1. To assist in the development of a new hardware front end electronics box for the fetal heart rate monitor, so as to reduce the size of the electronics box, and also to provide for a "low-frequency" and "high-frequency" mode of operation. To make necessary changes in the operating software to support the two modes of operation. 2. To provide an option for a strip chart recording for the system, so that medical personnel could more easily make comparisons with ultra sound strip chart recordings. and 3. To help with continued testing of the system.
Hoagland, Monica A; Chatterjee, Debnath
2017-04-01
Fetal therapy is an exciting and growing field of medicine. Advances in prenatal imaging and continued innovations in surgical and anesthetic techniques have resulted in a wide range of fetal interventions including minimally invasive, open mid-gestation, and ex-utero intrapartum treatment procedures. The potential for maternal morbidity is significant and must be carefully weighed against claimed benefits to the fetus. Appropriate patient selection is critical, and a multidisciplinary team-based approach is strongly recommended. The anesthetic management should focus on maintaining uteroplacental circulation, achieving profound uterine relaxation, optimizing surgical conditions, monitoring fetal hemodynamics, and minimizing maternal and fetal risk. © 2017 John Wiley & Sons Ltd.
Lu, Heqing; Zhang, Xiaofeng; Li, Bin
2017-09-30
Through illustrating the designing of high-risk pregnancy maternal-fetal monitoring system based on the internet of things, this paper introduced the specific application of using wearable medical devices to provide maternal-fetal mobile medical services. With the help of big data and cloud obstetrics platform, the monitoring and warning network was further improved, the level-to-level administration of high-risk pregnancy was realized, the level of perinatal health care was enhanced and the risk of critical emergency of pregnancy decreased.
What we have learned about intrapartum fetal monitoring trials in the MFMU Network.
Bloom, Steven L; Belfort, Michael; Saade, George
2016-08-01
The vast majority of pregnant women are subjected to electronic fetal heart monitoring during labor. There is limited evidence to support its benefit compared with intermittent auscultation. In addition, there is significant variability in interpretation and its false-positive rate is high. The latter may have contributed to the rise in operative deliveries. In order to address the critical need for better approaches to intrapartum monitoring, the MFMU Network has completed two large multisite randomized trials, one to evaluate fetal pulse oximetry and the other to evaluate fetal ECG ST segment analysis (STAN). Both of these technologies had been approved for clinical use in the United States based on prior smaller trials. These technologies were evaluated in laboring women near term and their primary outcomes were overall cesarean delivery for the oximetry trial and a composite adverse neonatal outcome for STAN. Both the trials failed to show a benefit of the technology, neither in the rates of operative deliveries nor in the rates of adverse neonatal outcomes. The experience with these trials, summarized in this report, highlights the need for rigorous evidence before introduction of new technology into clinical practice and provides a blueprint for future trials to address the need for better intrapartum monitoring approaches. Copyright © 2016 Elsevier Inc. All rights reserved.
Ahmad, Husna Azyan Binti; El-Badawy, Ismail M; Singh, Om Prakash; Hisham, Rozana Binti; Malarvili, M B
2018-04-27
Fetal heart rate (FHR) monitoring device is highly demanded to assess the fetus health condition in home environments. Conventional standard devices such as ultrasonography and cardiotocography are expensive, bulky and uncomfortable and consequently not suitable for long-term monitoring. Herein, we report a device that can be used to measure fetal heart rate in clinical and home environments. The proposed device measures and displays the FHR on a screen liquid crystal display (LCD). The device consists of hardware that comprises condenser microphone sensor, signal conditioning, microcontroller and LCD, and software that involves the algorithm used for processing the conditioned fetal heart signal prior to FHR display. The device's performance is validated based on analysis of variance (ANOVA) test. FHR data was recorded from 22 pregnant women during the 17th to 37th week of gestation using the developed device and two standard devices; AngelSounds and Electronic Stethoscope. The results show that F-value (1.5) is less than F, (3.1) and p-value (p> 0.05). Accordingly, there is no significant difference between the mean readings of the developed and existing devices. Hence, the developed device can be used for monitoring FHR in clinical and home environments.
Development of a Smart Mobile Data Module for Fetal Monitoring in E-Healthcare.
Houzé de l'Aulnoit, Agathe; Boudet, Samuel; Génin, Michaël; Gautier, Pierre-François; Schiro, Jessica; Houzé de l'Aulnoit, Denis; Beuscart, Régis
2018-03-23
The fetal heart rate (FHR) is a marker of fetal well-being in utero (when monitoring maternal and/or fetal pathologies) and during labor. Here, we developed a smart mobile data module for the remote acquisition and transmission (via a Wi-Fi or 4G connection) of FHR recordings, together with a web-based viewer for displaying the FHR datasets on a computer, smartphone or tablet. In order to define the features required by users, we modelled the fetal monitoring procedure (in home and hospital settings) via semi-structured interviews with midwives and obstetricians. Using this information, we developed a mobile data transfer module based on a Raspberry Pi. When connected to a standalone fetal monitor, the module acquires the FHR signal and sends it (via a Wi-Fi or a 3G/4G mobile internet connection) to a secure server within our hospital information system. The archived, digitized signal data are linked to the patient's electronic medical records. An HTML5/JavaScript web viewer converts the digitized FHR data into easily readable and interpretable graphs for viewing on a computer (running Windows, Linux or MacOS) or a mobile device (running Android, iOS or Windows Phone OS). The data can be viewed in real time or offline. The application includes tools required for correct interpretation of the data (signal loss calculation, scale adjustment, and precise measurements of the signal's characteristics). We performed a proof-of-concept case study of the transmission, reception and visualization of FHR data for a pregnant woman at 30 weeks of amenorrhea. She was hospitalized in the pregnancy assessment unit and FHR data were acquired three times a day with a Philips Avalon® FM30 fetal monitor. The prototype (Raspberry Pi) was connected to the fetal monitor's RS232 port. The emission and reception of prerecorded signals were tested and the web server correctly received the signals, and the FHR recording was visualized in real time on a computer, a tablet and smartphones (running Android and iOS) via the web viewer. This process did not perturb the hospital's computer network. There was no data delay or loss during a 60-min test. The web viewer was tested successfully in the various usage situations. The system was as user-friendly as expected, and enabled rapid, secure archiving. We have developed a system for the acquisition, transmission, recording and visualization of RCF data. Healthcare professionals can view the FHR data remotely on their computer, tablet or smartphone. Integration of FHR data into a hospital information system enables optimal, secure, long-term data archiving.
Fetal distress and the condition of newborn infants.
Sykes, G S; Molloy, P M; Johnson, P; Stirrat, G M; Turnbull, A C
1983-01-01
In a prospective audit of the obstetric management of 1210 consecutive deliveries the association was investigated between the need for operative delivery for fetal distress during labour and the condition of the newborn infant. Operative delivery was performed for only 11.5% of the newborn infants with severe acidosis at birth (umbilical artery pH less than 7.12, base deficit greater than 12 mmol (mEq)/1), 24.1% of those with an Apgar score less than 7 at one minute, and 15.8% of those with both severe acidosis and a one minute Apgar score less than 7. Most of the infants delivered operatively were in a vigorous condition at birth and did not have severe acidosis. Fetal blood sampling was done in 4.0% of labours. As none of the fetal blood values were less than 7.20 and only three of the infants sampled in utero suffered severe acidosis at birth, fetal blood sampling would have had to be performed much more often to provide a useful guide to metabolic state at birth. While the large majority of "at risk" fetuses had continuous fetal heart rate monitoring in labour, this had not been provided in 48.7% of the labours of infants with severe acidosis, 38.7% of infants with a one minute Apgar score less than 7, and 47.4% of infants with both severe acidosis and a one minute Apgar score less than 7. Continuous fetal heart rate monitoring was associated with a much higher incidence of operative delivery for fetal distress than was intermittent fetal heart rate auscultation. These results suggest an urgent need to review present methods for assessing the intrapartum condition of the fetus, making the diagnosis of fetal distress, and assessing the condition of the infant at birth. PMID:6412897
Reducing stillbirths: screening and monitoring during pregnancy and labour
Haws, Rachel A; Yakoob, Mohammad Yawar; Soomro, Tanya; Menezes, Esme V; Darmstadt, Gary L; Bhutta, Zulfiqar A
2009-01-01
Background Screening and monitoring in pregnancy are strategies used by healthcare providers to identify high-risk pregnancies so that they can provide more targeted and appropriate treatment and follow-up care, and to monitor fetal well-being in both low- and high-risk pregnancies. The use of many of these techniques is controversial and their ability to detect fetal compromise often unknown. Theoretically, appropriate management of maternal and fetal risk factors and complications that are detected in pregnancy and labour could prevent a large proportion of the world's 3.2 million estimated annual stillbirths, as well as minimise maternal and neonatal morbidity and mortality. Methods The fourth in a series of papers assessing the evidence base for prevention of stillbirths, this paper reviews available published evidence for the impact of 14 screening and monitoring interventions in pregnancy on stillbirth, including identification and management of high-risk pregnancies, advanced monitoring techniques, and monitoring of labour. Using broad and specific strategies to search PubMed and the Cochrane Library, we identified 221 relevant reviews and studies testing screening and monitoring interventions during the antenatal and intrapartum periods and reporting stillbirth or perinatal mortality as an outcome. Results We found a dearth of rigorous evidence of direct impact of any of these screening procedures and interventions on stillbirth incidence. Observational studies testing some interventions, including fetal movement monitoring and Doppler monitoring, showed some evidence of impact on stillbirths in selected high-risk populations, but require larger rigourous trials to confirm impact. Other interventions, such as amniotic fluid assessment for oligohydramnios, appear predictive of stillbirth risk, but studies are lacking which assess the impact on perinatal mortality of subsequent intervention based on test findings. Few rigorous studies of cardiotocography have reported stillbirth outcomes, but steep declines in stillbirth rates have been observed in high-income settings such as the U.S., where cardiotocography is used in conjunction with Caesarean section for fetal distress. Conclusion There are numerous research gaps and large, adequately controlled trials are still needed for most of the interventions we considered. The impact of monitoring interventions on stillbirth relies on use of effective and timely intervention should problems be detected. Numerous studies indicated that positive tests were associated with increased perinatal mortality, but while some tests had good sensitivity in detecting distress, false-positive rates were high for most tests, and questions remain about optimal timing, frequency, and implications of testing. Few studies included assessments of impact of subsequent intervention needed before recommending particular monitoring strategies as a means to decrease stillbirth incidence. In high-income countries such as the US, observational evidence suggests that widespread use of cardiotocography with Caesarean section for fetal distress has led to significant declines in stillbirth rates. Efforts to increase availability of Caesarean section in low-/middle-income countries should be coupled with intrapartum monitoring technologies where resources and provider skills permit. PMID:19426468
Custom FPGA processing for real-time fetal ECG extraction and identification.
Torti, E; Koliopoulos, D; Matraxia, M; Danese, G; Leporati, F
2017-01-01
Monitoring the fetal cardiac activity during pregnancy is of crucial importance for evaluating fetus health. However, there is a lack of automatic and reliable methods for Fetal ECG (FECG) monitoring that can perform this elaboration in real-time. In this paper, we present a hardware architecture, implemented on the Altera Stratix V FPGA, capable of separating the FECG from the maternal ECG and to correctly identify it. We evaluated our system using both synthetic and real tracks acquired from patients beyond the 20th pregnancy week. This work is part of a project aiming at developing a portable system for FECG continuous real-time monitoring. Its characteristics of reduced power consumption, real-time processing capability and reduced size make it suitable to be embedded in the overall system, that is the first proposed exploiting Blind Source Separation with this technology, to the best of our knowledge. Copyright © 2016 Elsevier Ltd. All rights reserved.
Automated Fetal Heart Rate Analysis in Labor: Decelerations and Overshoots
NASA Astrophysics Data System (ADS)
Georgieva, A. E.; Payne, S. J.; Moulden, M.; Redman, C. W. G.
2010-10-01
Electronic fetal heart rate (FHR) recording is a standard way of monitoring fetal health in labor. Decelerations and accelerations usually indicate fetal distress and normality respectively. But one type of acceleration may differ, namely an overshoot that may atypically reflect fetal stress. Here we describe a new method for detecting decelerations, accelerations and overshoots as part of a novel system for computerized FHR analysis (OxSyS). There was poor agreement between clinicians when identifying these FHR features visually, which precluded setting a gold standard of interpretation. We therefore introduced `modified' Sensitivity (SE°) and `modified' Positive Predictive Value (PPV°) as appropriate performance measures with which the algorithm was optimized. The relation between overshoots and fetal compromise in labor was studied in 15 cases and 15 controls. Overshoots showed promise as an indicator of fetal compromise. Unlike ordinary accelerations, overshoots cannot be considered to be reassuring features of fetal health.
Optimizing hidden layer node number of BP network to estimate fetal weight
NASA Astrophysics Data System (ADS)
Su, Juan; Zou, Yuanwen; Lin, Jiangli; Wang, Tianfu; Li, Deyu; Xie, Tao
2007-12-01
The ultrasonic estimation of fetal weigh before delivery is of most significance for obstetrical clinic. Estimating fetal weight more accurately is crucial for prenatal care, obstetrical treatment, choosing appropriate delivery methods, monitoring fetal growth and reducing the risk of newborn complications. In this paper, we introduce a method which combines golden section and artificial neural network (ANN) to estimate the fetal weight. The golden section is employed to optimize the hidden layer node number of the back propagation (BP) neural network. The method greatly improves the accuracy of fetal weight estimation, and simultaneously avoids choosing the hidden layer node number with subjective experience. The estimation coincidence rate achieves 74.19%, and the mean absolute error is 185.83g.
[Prenatal management of isolated IUGR].
Senat, M-V; Tsatsaris, V
2013-12-01
To evaluate the performance of different antenatal tools for the monitoring of fetuses with isolated intrauterine growth restriction (IUGR). To define the prenatal management of IUGR and indications for delivery before and after 32 weeks of gestation. PubMed, Embase and the Cochrane databases were searched using the keywords "IUGR", "fetal growth restriction", "cardiotocography", "amniotic fluid", "ultrasound assessment", "biophysical profile", "Doppler ultrasonography", "randomized trial", "meta-analysis". These terms were also combined together. Fetal monitoring of isolated IUGR should be based on the combined use of fetal heart rate (FHR) and ultrasound Doppler. The use of computerized FHR, with short-term variability (STV) measurement allows longitudinal monitoring and provides objective values upon which to decide very premature delivery (LE3). The use of umbilical Doppler is associated with a decrease in perinatal morbidity, especially in IUGR (LE1). It should be the first-line mean for the monitoring of SGA and IUGR fetuses (LE1). The additional use of cerebral Doppler is associated with a better predictive value for a poor perinatal outcome than the umbilical Doppler alone (LE3). Therefore, cerebral Doppler should be used in fetuses with IUGR, whether the umbilical Doppler is normal or not. As morbidity and mortality is increased in IUGR with pathological ductus venosus, the use of this Doppler should be considered in the monitoring of IUGR at before 32 weeks (professional consensus). Routine hospitalization is not mandatory for the monitoring of fetuses with IUGR/SGA. However, tertiary referral is advisable in cases of severe IUGR at between 26 to 32 weeks (professional consensus). The decision for delivery cannot be standardized and should be based on the combined analysis of gestational age, fetal heart rate analysis and Doppler study (professional consensus). Monitoring of fetuses with IUGR and decision for delivery should be based on the combined analysis of gestational age, fetal heart rate analysis and Doppler study before 32 weeks, this should ideally be performed by the association of computerized FHR and arterial and venous Doppler. Copyright © 2013. Published by Elsevier Masson SAS.
2015-01-01
Fetal heart rate surveillance is a standard component of intrapartum care. The fetal heart rate can be evaluated using intermittent auscultation or electronic fetal monitoring. Research that has compared these 2 strategies found them to be equivalent with respect to long-term neonatal outcomes. The purpose of this clinical bulletin by the American College of Nurse-Midwives is to review the evidence for use of intermittent auscultation and provide recommendations for intermittent auscultation technique, interpretation, and documentation. © 2015 by the American College of Nurse-Midwives.
Central Fetal Monitoring With and Without Computer Analysis: A Randomized Controlled Trial.
Nunes, Inês; Ayres-de-Campos, Diogo; Ugwumadu, Austin; Amin, Pina; Banfield, Philip; Nicoll, Antony; Cunningham, Simon; Sousa, Paulo; Costa-Santos, Cristina; Bernardes, João
2017-01-01
To evaluate whether intrapartum fetal monitoring with computer analysis and real-time alerts decreases the rate of newborn metabolic acidosis or obstetric intervention when compared with visual analysis. A randomized clinical trial carried out in five hospitals in the United Kingdom evaluated women with singleton, vertex fetuses of 36 weeks of gestation or greater during labor. Continuous central fetal monitoring by computer analysis and online alerts (experimental arm) was compared with visual analysis (control arm). Fetal blood sampling and electrocardiographic ST waveform analysis were available in both arms. The primary outcome was incidence of newborn metabolic acidosis (pH less than 7.05 and base deficit greater than 12 mmol/L). Prespecified secondary outcomes included operative delivery, use of fetal blood sampling, low 5-minute Apgar score, neonatal intensive care unit admission, hypoxic-ischemic encephalopathy, and perinatal death. A sample size of 3,660 per group (N=7,320) was planned to be able to detect a reduction in the rate of metabolic acidosis from 2.8% to 1.8% (two-tailed α of 0.05 with 80% power). From August 2011 through July 2014, 32,306 women were assessed for eligibility and 7,730 were randomized: 3,961 to computer analysis and online alerts, and 3,769 to visual analysis. Baseline characteristics were similar in both groups. Metabolic acidosis occurred in 16 participants (0.40%) in the experimental arm and 22 participants (0.58%) in the control arm (relative risk 0.69 [0.36-1.31]). No statistically significant differences were found in the incidence of secondary outcomes. Compared with visual analysis, computer analysis of fetal monitoring signals with real-time alerts did not significantly reduce the rate of metabolic acidosis or obstetric intervention. A lower-than-expected rate of newborn metabolic acidosis was observed in both arms of the trial. ISRCTN Registry, http://www.isrctn.com, ISRCTN42314164.
Antepartum Fetal Monitoring and Spectral Analysis of Preterm Birth Risk
NASA Astrophysics Data System (ADS)
Păsăricără, Alexandru; Nemescu, Dragoş; Arotăriţei, Dragoş; Rotariu, Cristian
2017-11-01
The monitoring and analysis of antepartum fetal and maternal recordings is a research area of notable interest due to the relatively high value of preterm birth. The interest stems from the improvement of devices used for monitoring. The current paper presents the spectral analysis of antepartum heart rate recordings conducted during a study in Romania at the Cuza Voda Obstetrics and Gynecology Clinical Hospital from Iasi between 2010 and 2014. The study focuses on normal and preterm birth risk subjects in order to determine differences between these two types or recordings in terms of spectral analysis.
Passive fetal monitoring sensor
NASA Astrophysics Data System (ADS)
1990-07-01
The invention is an ambulatory, passive sensor for use in a fetal monitoring system. The invention incorporates piezoelectric polymer film combined with a metallic mounting plate fastened to a belt and electrically connected to a signal processing unit by means of a shielded cable. The purpose of the sensor is to receive pressure pulses emitted from a fetus inside an expectant mother and to provide means for filtering out pressure pulses arising from other sources, such as the maternal heart.
Gyamfi Bannerman, Cynthia; Grobman, William A; Antoniewicz, Leah; Hutchinson, Maria; Blackwell, Sean
2011-09-01
In 2008, a National Institute of Child Health and Human Development/Society for Maternal-Fetal Medicine-sponsored workshop on electronic fetal monitoring recommended a new fetal heart tracing interpretation system. Comparison of this 3-tier system with other systems is lacking. Our purpose was to determine the relationships between fetal heart rate categories for the 3 existing systems. Three Maternal-Fetal Medicine specialists reviewed 120 fetal heart rates. All tracings were from term, singleton pregnancies with known umbilical artery pH. The fetal heart rates were classified by a 2-tier, 3-tier, and 5-tier system. Each Maternal-Fetal Medicine examiner reviewed 120 fetal heart rate segments. When compared with the 2-tier system, 0%, 54%, and 100% tracings in categories 1, 2, and 3 were "nonreassuring." There was strong concordance between category 1 and "green" as well as category 3 and "red" tracings. The 3-tier and 5-tier systems were similar in fetal heart rate interpretations for tracings that were either very normal or very abnormal. Whether one system is superior to the others in predicting fetal acidemia remains unknown. Copyright © 2011 Mosby, Inc. All rights reserved.
Use of diagnostic imaging procedures and fetal monitoring devices in the care of pregnant women.
Moore, R M; Jeng, L L; Kaczmarek, R G; Placek, P J
1990-01-01
Medical devices and diagnostic imaging procedures such as ultrasound, X-rays, and electronic fetal monitoring devices are used in the medical care of many pregnant women today. The responsibility for the safety and effectiveness of these diagnostic technologies is shared by a number of Public Health Service agencies, one of which is the Center for Devices and Radiological Health (CDRH), a unit within the Food and Drug Administration. The CDRH collaborated with the National Center for Health Statistics (NCHS) in conducting a study of recent trends in the uses of diagnostic ultrasound, medical X-rays, and electronic fetal monitoring devices in the medical care of pregnant women. This study used data from the 1980 National Natality and Fetal Mortality Surveys and the 1987 pretest to the National Maternal and Infant Health Survey. Hospitals and prenatal care providers of the pregnant women contributed information regarding the use of these medical devices. Between 1980 and 1987, ultrasound use more than doubled, increasing from 33.5 percent of pregnancies in 1980 to 78.8 percent in 1987 (P less than 0.001). More ultrasound examinations were performed earlier in gestation in 1987 than in 1980, with 10.1 percent being performed during the first trimester in 1987, compared with 6.9 percent in 1980 (P less than 0.001). Use of external electronic fetal monitoring devices during delivery also increased significantly between 1980 and 1987, from 33.5 percent to 74.6 percent (P less than 0.001). Use of medical X-rays among women with live births remained relatively unchanged, 15.0 percent in 1980 and 15.3 percent in 1987 (P = .282). The implications of these trends are discussed.
Feasibility of in utero telemetric fetal ECG monitoring in a lamb model.
Hermans, Bart; Lewi, Liesbeth; Jani, Jacques; De Buck, Frederik; Deprest, Jan; Puers, Robert
2008-01-01
If fetal ECG (fECG) devices could be miniaturized sufficiently, one could consider their implantation at the time of fetal surgery to allow permanent monitoring of the fetus and timely intervention in the viable period. We set up an experiment to evaluate the feasibility of in utero direct fECG monitoring and telemetric transmission using a small implantable device in a lamb model. A 2-lead miniature ECG sensor (volume 1.9 cm(3); weight 3.9 g) was subcutaneously implanted in 2 fetal lambs at 122 days gestation (range 119-125; term 145 days). The ECG sensor can continuously register and transmit fECG. The signal is captured by an external receiving antenna taped to the maternal abdominal wall. We developed dedicated software running on a commercial laptop for on-line analysis of the transmitted fECG signal. This was a noninterventional study, i.e. daily readings of the fECG signal were done without clinical consequences to the observations. fECG could be successfully registered, transmitted by telemetry and analyzed from the moment of implantation till term birth in one case (24 days). In the second case, unexplained in utero fetal death occurred 12 days after implantation. In this subject, agonal fECG changes were recorded. An implanted miniature (<2 ml) ECG sensor can be used to retrieve, process and transmit continuously a qualitative fECG signal in third-trimester fetal lambs. The telemetric signal could be picked up by an external antenna located within a 20-cm range. In this experiment, this was achieved through taping the external receiver to the maternal abdomen. Any acquired signal could be transmitted to a commercially available laptop that could perform on-line analysis of the signal. (c) 2008 S. Karger AG, Basel.
Vijgen, Sylvia M C; Westerhuis, Michelle E M H; Opmeer, Brent C; Visser, Gerard H A; Moons, Karl G M; Porath, Martina M; Oei, Guid S; Van Geijn, Herman P; Bolte, Antoinette C; Willekes, Christine; Nijhuis, Jan G; Van Beek, Erik; Graziosi, Giuseppe C M; Schuitemaker, Nico W E; Van Lith, Jan M M; Van Den Akker, Eline S A; Drogtrop, Addy P; Van Dessel, Hendrikus J H M; Rijnders, Robbert J P; Oosterbaan, Herman P; Mol, Ben Willem J; Kwee, Anneke
2011-07-01
To assess the cost-effectiveness of addition of ST analysis of the fetal electrocardiogram (ECG; STAN) to cardiotocography (CTG) for fetal surveillance during labor compared with CTG only. Cost-effectiveness analysis based on a randomized clinical trial on ST analysis of the fetal ECG. Obstetric departments of three academic and six general hospitals in The Netherlands. Population. Laboring women with a singleton high-risk pregnancy, a fetus in cephalic presentation, a gestational age >36 weeks and an indication for internal electronic fetal monitoring. A trial-based cost-effectiveness analysis was performed from a health-care provider perspective. Primary health outcome was the incidence of metabolic acidosis measured in the umbilical artery. Direct medical costs were estimated from start of labor to childbirth. Cost-effectiveness was expressed as costs to prevent one case of metabolic acidosis. The incidence of metabolic acidosis was 0.7% in the ST-analysis group and 1.0% in the CTG-only group (relative risk 0.70; 95% confidence interval 0.38-1.28). Per delivery, the mean costs per patient of CTG plus ST analysis (n= 2 827) were €1,345 vs. €1,316 for CTG only (n= 2 840), with a mean difference of €29 (95% confidence interval -€9 to €77) until childbirth. The incremental costs of ST analysis to prevent one case of metabolic acidosis were €9 667. The additional costs of monitoring by ST analysis of the fetal ECG are very limited when compared with monitoring by CTG only and very low compared with the total costs of delivery. © 2011 The Authors Acta Obstetricia et Gynecologica Scandinavica© 2011 Nordic Federation of Societies of Obstetrics and Gynecology.
Warmerdam, G; Vullings, R; Van Pul, C; Andriessen, P; Oei, S G; Wijn, P
2013-01-01
Non-invasive fetal electrocardiography (ECG) can be used for prolonged monitoring of the fetal heart rate (FHR). However, the signal-to-noise-ratio (SNR) of non-invasive ECG recordings is often insufficient for reliable detection of the FHR. To overcome this problem, source separation techniques can be used to enhance the fetal ECG. This study uses a physiology-based source separation (PBSS) technique that has already been demonstrated to outperform widely used blind source separation techniques. Despite the relatively good performance of PBSS in enhancing the fetal ECG, PBSS is still susceptible to artifacts. In this study an augmented PBSS technique is developed to reduce the influence of artifacts. The performance of the developed method is compared to PBSS on multi-channel non-invasive fetal ECG recordings. Based on this comparison, the developed method is shown to outperform PBSS for the enhancement of the fetal ECG.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Georgieva, A. E.; Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Old Road Campus Research Building Oxford OX3 7DQ; Payne, S. J.
Electronic fetal heart rate (FHR) recording is a standard way of monitoring fetal health in labor. Decelerations and accelerations usually indicate fetal distress and normality respectively. But one type of acceleration may differ, namely an overshoot that may atypically reflect fetal stress. Here we describe a new method for detecting decelerations, accelerations and overshoots as part of a novel system for computerized FHR analysis (OxSyS). There was poor agreement between clinicians when identifying these FHR features visually, which precluded setting a gold standard of interpretation. We therefore introduced 'modified' Sensitivity (SE deg.) and 'modified' Positive Predictive Value (PPV deg.) asmore » appropriate performance measures with which the algorithm was optimized. The relation between overshoots and fetal compromise in labor was studied in 15 cases and 15 controls. Overshoots showed promise as an indicator of fetal compromise. Unlike ordinary accelerations, overshoots cannot be considered to be reassuring features of fetal health.« less
Spyridou, K; Chouvarda, I; Hadjileontiadis, L; Maglaveras, N
2018-01-30
This work aims to investigate the impact of gestational age and fetal gender on fetal heart rate (FHR) tracings. Different linear and nonlinear parameters indicating correlation or complexity were used to study the influence of fetal age and gender on FHR tracings. The signals were recorded from 99 normal pregnant women in a singleton pregnancy at gestational ages from 28 to 40 weeks, before the onset of labor. There were 56 female fetuses and 43 male. Analysis of FHR shows that the means as well as measures of irregularity of FHR, such as approximate entropy and algorithmic complexity, decrease as gestation progresses. There were also indications that mutual information and multiscale entropy were lower in male fetuses in early pregnancy. Fetal age and gender seem to influence FHR tracings. Taking this into consideration would improve the interpretation of FHR monitoring.
Legionnaire's disease complicating pregnancy: a case report with intrauterine fetal demise.
Vimercati, A; Greco, P; Bettocchi, S; Resta, L; Selvaggi, L
2000-01-01
Legionnaire's disease complicating pregnancy is an unusual event that can seriously compromise both the mother and the fetus. We describe one case of such association, with an unfavourable intrauterine fetal outcome, secondary to acute placental insufficiency, related to infection. It is important in these high risk pregnancies complicated by acute pneumonia to take into consideration the diagnosis, as early as possible, and the appropriate treatment or the careful monitoring of fetal wellbeing.
Thanaraj, Palani; Roshini, Mable; Balasubramanian, Parvathavarthini
2016-11-14
The fetal electrocardiogram (FECG) signals are essential to monitor the health condition of the baby. Fetal heart rate (FHR) is commonly used for diagnosing certain abnormalities in the formation of the heart. Usually, non-invasive abdominal electrocardiogram (AbECG) signals are obtained by placing surface electrodes in the abdomen region of the pregnant woman. AbECG signals are often not suitable for the direct analysis of fetal heart activity. Moreover, the strength and magnitude of the FECG signals are low compared to the maternal electrocardiogram (MECG) signals. The MECG signals are often superimposed with the FECG signals that make the monitoring of FECG signals a difficult task. Primary goal of the paper is to separate the fetal electrocardiogram (FECG) signals from the unwanted maternal electrocardiogram (MECG) signals. A multivariate signal processing procedure is proposed here that combines the Multivariate Empirical Mode Decomposition (MEMD) and Independent Component Analysis (ICA). The proposed method is evaluated with clinical abdominal signals taken from three pregnant women (N= 3) recorded during the 38-41 weeks of the gestation period. The number of fetal R-wave detected (NEFQRS), the number of unwanted maternal peaks (NMQRS), the number of undetected fetal R-wave (NUFQRS) and the FHR detection accuracy quantifies the performance of our method. Clinical investigation with three test subjects shows an overall detection accuracy of 92.8%. Comparative analysis with benchmark signal processing method such as ICA suggests the noteworthy performance of our method.
Contribution of fetal brain MRI in management of severe fetal anemia.
Ghesquière, L; Houfflin-Debarge, V; Verpillat, P; Fourquet, T; Joriot, S; Coulon, C; Vaast, P; Garabedian, C
2018-06-06
Intrauterine transfusion (IUT) has changed fetal anemia prognosis. However, long-term neurodevelopmental outcome is altered in 5% of children. Our objective was to study the contribution of fetal MRI to diagnosis brain lesions in case of fetal anemia. Retrospective monocentric descriptive study from 2005 to 2016, including all patients followed for fetal anemia requiring IUT. The indications for MRI were: hydrops fetalis and / or hemoglobin <5 g / dL and / or more than 3 IUTs and / or acute severe anemia and / or ultrasound abnormality. Fetal and neonatal outcome and pediatric neurological monitoring were studied. 89 patients were followed for fetal anemia with IUT and 28 (29.1%) had fetal MRI, 12 of which were abnormal. Two out of twelve had abnormal ultrasound. Seven out of twelve had poor neurological prognosis: 2 medical terminations of pregnancy were performed; 2 children had severe developmental delay and 3 children had schooling difficulties. Five out of twelve children had favorable neurological prognosis. MRI of the fetal brain makes it possible to better detect brain lesions than ultrasound does in the management of severe fetal anemia and seems particularly appropriate in cases of acute anemia. Copyright © 2018 Elsevier B.V. All rights reserved.
Estimation of Measurement Characteristics of Ultrasound Fetal Heart Rate Monitor
NASA Astrophysics Data System (ADS)
Noguchi, Yasuaki; Mamune, Hideyuki; Sugimoto, Suguru; Yoshida, Atsushi; Sasa, Hidenori; Kobayashi, Hisaaki; Kobayashi, Mitsunao
1995-05-01
Ultrasound fetal heart rate monitoring is very useful to determine the status of the fetus because it is noninvasive. In order to ensure the accuracy of the fetal heart rate (FHR) obtained from the ultrasound Doppler data, we measure the fetal electrocardiogram (ECG) directly and obtain the Doppler data simultaneously. The FHR differences of the Doppler data from the direct ECG data are concentrated at 0 bpm (beats per minute), and are practically symmetrical. The distribution is found to be very close to the Student's t distribution by the test of goodness of fit with the chi-square test. The spectral density of the FHR differences shows the white noise spectrum without any dominant peaks. Furthermore, the f-n (n>1) fluctuation is observed both with the ultrasound Doppler FHR and with the direct ECG FHR. Thus, it is confirmed that the FHR observation and observation of the f-n (n>1) fluctuation using the ultrasound Doppler FHR are as useful as the direct ECG.
Fetal ECG extraction using independent component analysis by Jade approach
NASA Astrophysics Data System (ADS)
Giraldo-Guzmán, Jader; Contreras-Ortiz, Sonia H.; Lasprilla, Gloria Isabel Bautista; Kotas, Marian
2017-11-01
Fetal ECG monitoring is a useful method to assess the fetus health and detect abnormal conditions. In this paper we propose an approach to extract fetal ECG from abdomen and chest signals using independent component analysis based on the joint approximate diagonalization of eigenmatrices approach. The JADE approach avoids redundancy, what reduces matrix dimension and computational costs. Signals were filtered with a high pass filter to eliminate low frequency noise. Several levels of decomposition were tested until the fetal ECG was recognized in one of the separated sources output. The proposed method shows fast and good performance.
Tracking fetal development through molecular analysis of maternal biofluids☆
Edlow, Andrea G.; Bianchi, Diana W.
2015-01-01
Current monitoring of fetal development includes fetal ultrasonography, chorionic villus sampling or amniocentesis for chromosome analysis, and maternal serum biochemical screening for analytes associated with aneuploidy and open neural tube defects. Over the last 15 years, significant advances in noninvasive prenatal diagnosis (NIPD) via cell-free fetal (cff) nucleic acids in maternal plasma have resulted in the ability to determine fetal sex, RhD genotype, and aneuploidy. Cff nucleic acids in the maternal circulation originate primarily from the placenta. This contrasts with cff nucleic acids in amniotic fluid, which derive from the fetus, and are present in significantly higher concentrations than in maternal blood. The fetal origin of cff nucleic acids in the amniotic fluid permits the acquisition of real-time information about fetal development and gene expression. This review seeks to provide a comprehensive summary of the molecular analysis of cff nucleic acids in maternal biofluids to elucidate mechanisms of fetal development, physiology, and pathology. This article is part of a Special Issue entitled: Molecular Genetics of Human Reproductive Failure. PMID:22542507
Effect of tocolytic drugs on fetal heart rate variability: a systematic review.
Verdurmen, Kim M J; Hulsenboom, Alexandra D J; van Laar, Judith O E H; Oei, S Guid
2017-10-01
Tocolytics may cause changes in fetal heart rate (HR) pattern, while fetal heart rate variability (HRV) is an important marker of fetal well-being. We aim to systematically review the literature on how tocolytic drugs affect fetal HRV. We searched CENTRAL, PubMed and EMBASE up to June 2016. Studies published in English, using computerized or visual analysis to describe the effect of tocolytics on HRV in human fetuses were included. Studies describing tocolytics during labor, external cephalic version, pre-eclampsia and infection were excluded. Eventually, we included six studies, describing 169 pregnant women. Nifedipine, atosiban and indomethacin administration show no clinically important effect on fetal HRV. Following administration of magnesium sulfate decreased variability and cases of bradycardia are described. Fenoterol administration results in a slight increase in fetal HR with no changes in variability. After ritodrine administration increased fetal HR and decreased variability is seen. The effect of co-administration of corticosteroids should be taken into account. In order to prevent iatrogenic preterm labor, the effects of tocolytic drugs on fetal HRV should be taken into account when monitoring these fetuses.
Lee, Kwang Jin; Lee, Boreom
2016-01-01
Fetal heart rate (FHR) is an important determinant of fetal health. Cardiotocography (CTG) is widely used for measuring the FHR in the clinical field. However, fetal movement and blood flow through the maternal blood vessels can critically influence Doppler ultrasound signals. Moreover, CTG is not suitable for long-term monitoring. Therefore, researchers have been developing algorithms to estimate the FHR using electrocardiograms (ECGs) from the abdomen of pregnant women. However, separating the weak fetal ECG signal from the abdominal ECG signal is a challenging problem. In this paper, we propose a method for estimating the FHR using sequential total variation denoising and compare its performance with that of other single-channel fetal ECG extraction methods via simulation using the Fetal ECG Synthetic Database (FECGSYNDB). Moreover, we used real data from PhysioNet fetal ECG databases for the evaluation of the algorithm performance. The R-peak detection rate is calculated to evaluate the performance of our algorithm. Our approach could not only separate the fetal ECG signals from the abdominal ECG signals but also accurately estimate the FHR. PMID:27376296
Lee, Kwang Jin; Lee, Boreom
2016-07-01
Fetal heart rate (FHR) is an important determinant of fetal health. Cardiotocography (CTG) is widely used for measuring the FHR in the clinical field. However, fetal movement and blood flow through the maternal blood vessels can critically influence Doppler ultrasound signals. Moreover, CTG is not suitable for long-term monitoring. Therefore, researchers have been developing algorithms to estimate the FHR using electrocardiograms (ECGs) from the abdomen of pregnant women. However, separating the weak fetal ECG signal from the abdominal ECG signal is a challenging problem. In this paper, we propose a method for estimating the FHR using sequential total variation denoising and compare its performance with that of other single-channel fetal ECG extraction methods via simulation using the Fetal ECG Synthetic Database (FECGSYNDB). Moreover, we used real data from PhysioNet fetal ECG databases for the evaluation of the algorithm performance. The R-peak detection rate is calculated to evaluate the performance of our algorithm. Our approach could not only separate the fetal ECG signals from the abdominal ECG signals but also accurately estimate the FHR.
Vairavan, S; Ulusar, U D; Eswaran, H; Preissl, H; Wilson, J D; Mckelvey, S S; Lowery, C L; Govindan, R B
2016-02-01
We propose a novel computational approach to automatically identify the fetal heart rate patterns (fHRPs), which are reflective of sleep/awake states. By combining these patterns with presence or absence of movements, a fetal behavioral state (fBS) was determined. The expert scores were used as the gold standard and objective thresholds for the detection procedure were obtained using Receiver Operating Characteristics (ROC) analysis. To assess the performance, intraclass correlation was computed between the proposed approach and the mutually agreed expert scores. The detected fHRPs were then associated to their corresponding fBS based on the fetal movement obtained from fetal magnetocardiogaphic (fMCG) signals. This approach may aid clinicians in objectively assessing the fBS and monitoring fetal wellbeing. Copyright © 2015 Elsevier Ltd. All rights reserved.
Buss, Claudia; Davis, Elysia Poggi; Class, Quetzal A; Gierczak, Matt; Pattillo, Carol; Glynn, Laura M; Sandman, Curt A
2009-10-01
Despite the evidence for early fetal experience exerting programming influences on later neurological development and health risk, very few prospective studies of human fetal behavior have been reported. In a prospective longitudinal study, fetal nervous system maturation was serially assessed by monitoring fetal heart rate (FHR) responses to vibroacoustic stimulation (VAS) in 191 maternal/fetal dyads. Responses were not detected at 26 weeks gestational age (GA). Sex-specific, age-characteristic changes in the FHR response to VAS were observed by 31 weeks' GA. Males showed larger responses and continued to exhibit maturational changes until 37 weeks' GA, females however, presented with a mature FHR startle response by 31 weeks' GA. The results indicate that there are different rates of maturation in the male and female fetuses that may have implications for sex-specific programming influences.
Verdurmen, Kim M J; Warmerdam, Guy J J; Lempersz, Carlijn; Hulsenboom, Alexandra D J; Renckens, Joris; Dieleman, Jeanne P; Vullings, Rik; van Laar, Judith O E H; Oei, S Guid
2018-04-01
Betamethasone is widely used to enhance fetal lung maturation in case of threatened preterm labour. Fetal heart rate variability is one of the most important parameters to assess in fetal monitoring, since it is a reliable indicator for fetal distress. To describe the effect of betamethasone on fetal heart rate variability, by applying spectral analysis on non-invasive fetal electrocardiogram recordings. Prospective cohort study. Patients that require betamethasone, with a gestational age from 24 weeks onwards. Fetal heart rate variability parameters on day 1, 2, and 3 after betamethasone administration are compared to a reference measurement. Following 68 inclusions, 12 patients remained with complete series of measurements and sufficient data quality. During day 1, an increase in absolute fetal heart rate variability values was seen. During day 2, a decrease in these values was seen. All trends indicate to return to pre-medication values on day 3. Normalised high- and low-frequency power show little changes during the study period. The changes in fetal heart rate variability following betamethasone administration show the same pattern when calculated by spectral analysis of the fetal electrocardiogram, as when calculated by cardiotocography. Since normalised spectral values show little changes, the influence of autonomic modulation seems minor. Copyright © 2018 Elsevier B.V. All rights reserved.
Method for simultaneously making a plurality of acoustic signal sensor elements
NASA Technical Reports Server (NTRS)
Bryant, Timothy D. (Inventor); Wynkoop, Mark W. (Inventor); Holloway, Nancy M. H. (Inventor); Zuckerwar, Allan J. (Inventor)
2005-01-01
A fetal heart monitoring system preferably comprising a backing plate having a generally concave front surface and a generally convex back surface, and at least one sensor element attached to the concave front surface for acquiring acoustic fetal heart signals produced by a fetus within a body. The sensor element has a shape that conforms to the generally concave back surface of the backing plate. In one embodiment, the at least one sensor element comprises an inner sensor, and a plurality of outer sensors surrounding the inner sensor. The fetal heart monitoring system can further comprise a web belt, and a web belt guide movably attached to the web belt. The web belt guide being is to the convex back surface of the backing plate.
Method for Simultaneously Making a Plurality of Acoustic Signal Sensor Elements
NASA Technical Reports Server (NTRS)
Bryant, Timothy D.; Wynkoop, Mark W.; Holloway, Nancy M. H.; Zuckerwar, Allan J.
2005-01-01
A fetal heart monitoring system preferably comprising a backing plate having a generally concave front surface and a generally convex back surface, and at least one sensor element attached to the concave front surface for acquiring acoustic fetal heart signals produced by a fetus within a body. The sensor element has a shape that conforms to the generally concave back surface of the backing plate. In one embodiment, the at least one sensor element comprises an inner sensor, and a plurality of outer sensors surrounding the inner sensor. The fetal heart monitoring system can further comprise a web belt, and a web belt guide movably attached to the web belt. The web belt guide being is to the convex back surface of the backing plate.
Halaska, M J; Komar, M; Vlk, R; Tomek, V; Skultety, J; Robova, H; Rob, L
2014-03-01
To monitor fetal anemia during administration of chemotherapy to the fetus's mother. Between 2007 and 2012 six patients with malignancy diagnosed during pregnancy were included in our prospective study. For evaluation of fetal anemia, peak systolic velocimetry (PSV) of the middle cerebral artery is considered the best method. The patients were repeatedly examined one day before and on the third day after the administration of chemotherapy. At least three measurements were performed and the highest value was used as appropriate. Multiples of the median (MoM) were calculated using the website http://www.perinatology.com/calculators/MCA.htm. When the MoM reached 1.29, moderate anemia was diagnosed. The women's average age was 30 years. The average gestational age at diagnosis was 20.7 weeks of pregnancy. Borderline fetal anemia was detected in only in one patient. After delivery newborns were examined by standard pediatric evaluation and blood count was provided. There was no evidence of any newborn anemia. Chemotherapy administered during pregnancy is becoming more frequent due to increasing knowledge and data on such cases. Close monitoring of the fetus should be performed in specialized centers. For detection of chemotherapy-induced anemia, PSV measurement should be employed. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Ryan, Gareth; Dooley, Joe; Windrim, Rory; Bollinger, Megan; Gerber Finn, Lianne; Kelly, Len
2017-06-01
To describe/analyse a novel, community-based prenatal monitoring protocol for opioid-exposed pregnancies developed by our centre in 2014 to optimize prenatal care for this population. A literature review of published monitoring protocols for this population is also presented. Retrospective comparison of pre-protocol (n = 215) and post-protocol (n = 251) cohorts. Medline and Embase were searched between 2000-2016 using MeSH terms: [fetal monitoring OR prenatal care] AND [opioid-related disorders OR substance-related disorders] in Medline and [fetal monitoring OR prenatal care] AND [opiate addiction OR substance abuse] in Embase, producing 518 results. Thirteen studies included protocols for monitoring opioid-exposed pregnancies. No comprehensive monitoring protocols with high-quality supporting evidence were found. We evaluated 466 opioid-exposed pregnancies, 215 before and 251 after introduction of the protocol. Since implementation, there was a significant increase in the number of opioid-exposed patients who have underwent urine drug screening (72.6% to 89.2%, P < 0.0001); a significant reduction in the number of urine drug screenings positive for illicit opioids (50.2% to 29.1%, P < 0.0001); and a significant increase in the number of patients who discontinued illicit opioid use by the time of delivery (24.7% to 39.4%, P < 0.01). There was no difference in the CS rate (27.4% vs. 26.3%, P > 0.05). There were no observed differences in the rate of preterm birth, birth weight <2500 g, or Apgar score <7 (P > 0.05). Care of women with increased opioid use during pregnancy is an important but under-studied health issue. A novel protocol for focused antenatal care provision for women with opioid-exposed pregnancies improves standard of care and maternal/fetal outcomes. Copyright © 2017. Published by Elsevier Inc.
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2014 CFR
2014-04-01
... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2012 CFR
2012-04-01
... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2013 CFR
2013-04-01
... monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Computerized Labor Monitoring System. 884.2800... (CONTINUED) MEDICAL DEVICES OBSTETRICAL AND GYNECOLOGICAL DEVICES Obstetrical and Gynecological Monitoring...
Apparatus for Assisting Childbirth
NASA Technical Reports Server (NTRS)
Smeltzer, Stanley S., III (Inventor); Lawson, Seth W. (Inventor)
1997-01-01
The invention consists of novel, scissors-like forceps in combination with optical monitoring hardware for measuring the extraction forces on a fetal head. The novel features of the forceps together with knowledge of real time forces on the fetal head enable a user to make a much safer delivery for mother and baby.
A Managed Care Model for the Military Departments
1990-05-15
Seattle reports that a widely used technique for electronic monitoring of a fetal heart during delivery is "no more effective than a stethoscope in 6...detecting fetal distress." The study director went on to say that obstetricians will probably continue to use the technique to avoid possible
A novel technique for fetal heart rate estimation from Doppler ultrasound signal
2011-01-01
Background The currently used fetal monitoring instrumentation that is based on Doppler ultrasound technique provides the fetal heart rate (FHR) signal with limited accuracy. It is particularly noticeable as significant decrease of clinically important feature - the variability of FHR signal. The aim of our work was to develop a novel efficient technique for processing of the ultrasound signal, which could estimate the cardiac cycle duration with accuracy comparable to a direct electrocardiography. Methods We have proposed a new technique which provides the true beat-to-beat values of the FHR signal through multiple measurement of a given cardiac cycle in the ultrasound signal. The method consists in three steps: the dynamic adjustment of autocorrelation window, the adaptive autocorrelation peak detection and determination of beat-to-beat intervals. The estimated fetal heart rate values and calculated indices describing variability of FHR, were compared to the reference data obtained from the direct fetal electrocardiogram, as well as to another method for FHR estimation. Results The results revealed that our method increases the accuracy in comparison to currently used fetal monitoring instrumentation, and thus enables to calculate reliable parameters describing the variability of FHR. Relating these results to the other method for FHR estimation we showed that in our approach a much lower number of measured cardiac cycles was rejected as being invalid. Conclusions The proposed method for fetal heart rate determination on a beat-to-beat basis offers a high accuracy of the heart interval measurement enabling reliable quantitative assessment of the FHR variability, at the same time reducing the number of invalid cardiac cycle measurements. PMID:21999764
21 CFR 884.2800 - Computerized Labor Monitoring System.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Computerized Labor Monitoring System. 884.2800... Devices § 884.2800 Computerized Labor Monitoring System. (a) Identification. A computerized labor monitoring system is a system intended to continuously measure cervical dilation and fetal head descent and...
A uniform management approach to optimize outcome in fetal growth restriction.
Seravalli, Viola; Baschat, Ahmet A
2015-06-01
A uniform approach to the diagnosis and management of fetal growth restriction (FGR) consistently produces better outcome, prevention of unanticipated stillbirth, and appropriate timing of delivery. Early-onset and late-onset FGR represent two distinct clinical phenotypes of placental dysfunction. Management challenges in early-onset FGR revolve around prematurity and coexisting maternal hypertensive disease, whereas in late-onset disease failure of diagnosis or surveillance leading to unanticipated stillbirth is the primary issue. Identifying the surveillance tests that have the highest predictive accuracy for fetal acidemia and establishing the appropriate monitoring interval to detect fetal deterioration is a high priority. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yan, Hua-Wen; Huang, Xiao-Lin; Zhao, Ying; Si, Jun-Feng; Liu, Tie-Bing; Liu, Hong-Xing
2014-11-01
A series of experiments are conducted to confirm whether the vectors calculated for an early section of a continuous non-invasive fetal electrocardiogram (fECG) recording can be directly applied to subsequent sections in order to reduce the computation required for real-time monitoring. Our results suggest that it is generally feasible to apply the initial optimal maternal and fetal ECG combination vectors to extract the fECG and maternal ECG in subsequent recorded sections.
Monitoring the condition of the fetus during delivery.
Sarvilinna, Nanna; Isaksson, Camilla; Kokljuschkin, Henrica; Timonen, Susanna; Halmesmäki, Erja
Uterine contractions during delivery increase the resistance to flow in the blood vessels of the placenta and decreases placental blood circulation, possibly subjecting the fetus to hypoxia. Several methods have been developed for monitoring the condition of the fetus during delivery. Cardiotocography is used to monitor the fetus's heart rate and variability in relation to the mother's contractions. A change in cardiotocography recording due to stimulation of the presenting part is an indication of a healthy fetus. ST analysis of fetal ECG depicts the oxygenation of fetal cardiac muscle during delivery. In addition to cardiotocography and ST analysis, analysis of blood gases and lactate determination are used in assessing the condition of the fetus.
Multi-channel non-invasive fetal electrocardiography detection using wavelet decomposition
NASA Astrophysics Data System (ADS)
Almeida, Javier; Ruano, Josué; Corredor, Germán.; Romo-Bucheli, David; Navarro-Vargas, José Ricardo; Romero, Eduardo
2017-11-01
Non-invasive fetal electrocardiography (fECG) has attracted the medical community because of the importance of fetal monitoring. However, its implementation in clinical practice is challenging: the fetal signal has a low Signal- to-Noise-Ratio and several signal sources are present in the maternal abdominal electrocardiography (AECG). This paper presents a novel method to detect the fetal signal from a multi-channel maternal AECG. The method begins by applying filters and signal detrending the AECG signals. Afterwards, the maternal QRS complexes are identified and subtracted. The residual signals are used to detect the fetal QRS complex. Intervals of these signals are analyzed by using a wavelet decomposition. The resulting representation feds a previously trained Random Forest (RF) classifier that identifies signal intervals associated to fetal QRS complex. The method was evaluated on a public available dataset: the Physionet2013 challenge. A set of 50 maternal AECG records were used to train the RF classifier. The evaluation was carried out in signals intervals extracted from additional 25 maternal AECG. The proposed method yielded an 83:77% accuracy in the fetal QRS complex classification task.
NASA Astrophysics Data System (ADS)
Struzik, Zbigniew R.; van Wijngaarden, Willem J.
We introduce a special purpose cumulative indicator, capturing in real time the cumulative deviation from the reference level of the exponent h (local roughness, Hölder exponent) of the fetal heartbeat during labour. We verify that the indicator applied to the variability component of the heartbeat coincides with the fetal outcome as determined by blood samples. The variability component is obtained from running real time decomposition of fetal heartbeat into independent components using an adaptation of an oversampled Haar wavelet transform. The particular filters used and resolutions applied are motivated by obstetricial insight/practice. The methodology described has the potential for real-time monitoring of the fetus during labour and for the prediction of the fetal outcome, allerting the attending staff in the case of (threatening) hypoxia.
Lavesson, Tony; Amer-Wåhlin, Isis; Hansson, Stefan; Ley, David; Marsál, Karel; Olofsson, Per
2010-06-01
To evaluate a new technical equipment for continuous recording of human fetal scalp temperature in labor. Experimental animal study. Two temperature sensors were placed subcutaneously and intracranially on the forehead of 10 fetal lambs and connected to a temperature monitoring system. The system records temperatures simultaneously on-line and stores data to be analyzed off-line. Throughout the experiment, the fetus was oxygenated via the umbilical cord circulation. Asphyxia was induced by intermittent cord compression, as assessed by pH in jugular vein blood. The intracranial (ICT) and subcutaneous (SCT) temperatures were compared with simple and polynomial regression analyses. Absolute and delta ICT and SCT changes. ICT and SCT were both successfully recorded in all 10 cases. With increasing acidosis, the temperatures decreased. The correlation coefficient between ICT and SCT had a range of 0.76-0.97 (median 0.88) by simple linear regression and 0.80-0.99 (median 0.89) by second grade polynomial regression. After an initial system stabilization period of 10 minutes, the delta temperature values (ICT minus SCT) were less than 1.5 degrees C throughout the experiment in all but one case. The fetal forehead SCT mirrored the ICT closely, with the ICT being higher.
NASA Astrophysics Data System (ADS)
Mantini, D.; Alleva, G.; Comani, S.
2005-10-01
Fetal magnetocardiography (fMCG) allows monitoring the fetal heart function through algorithms able to retrieve the fetal cardiac signal, but no standardized automatic model has become available so far. In this paper, we describe an automatic method that restores the fetal cardiac trace from fMCG recordings by means of a weighted summation of fetal components separated with independent component analysis (ICA) and identified through dedicated algorithms that analyse the frequency content and temporal structure of each source signal. Multichannel fMCG datasets of 66 healthy and 4 arrhythmic fetuses were used to validate the automatic method with respect to a classical procedure requiring the manual classification of fetal components by an expert investigator. ICA was run with input clusters of different dimensions to simulate various MCG systems. Detection rates, true negative and false positive component categorization, QRS amplitude, standard deviation and signal-to-noise ratio of reconstructed fetal signals, and real and per cent QRS differences between paired fetal traces retrieved automatically and manually were calculated to quantify the performances of the automatic method. Its robustness and reliability, particularly evident with the use of large input clusters, might increase the diagnostic role of fMCG during the prenatal period.
Linear Phase Sharp Transition BPF to Detect Noninvasive Maternal and Fetal Heart Rate.
Marchon, Niyan; Naik, Gourish; Pai, K R
2018-01-01
Fetal heart rate (FHR) detection can be monitored using either direct fetal scalp electrode recording (invasive) or by indirect noninvasive technique. Weeks before delivery, the invasive method poses a risk factor to the fetus, while the latter provides accurate fetal ECG (FECG) information which can help diagnose fetal's well-being. Our technique employs variable order linear phase sharp transition (LPST) FIR band-pass filter which shows improved stopband attenuation at higher filter orders. The fetal frequency fiduciary edges form the band edges of the filter characterized by varying amounts of overlap of maternal ECG (MECG) spectrum. The one with the minimum maternal spectrum overlap was found to be optimum with no power line interference and maximum fetal heart beats being detected. The improved filtering is reflected in the enhancement of the performance of the fetal QRS detector (FQRS). The improvement has also occurred in fetal heart rate obtained using our algorithm which is in close agreement with the true reference (i.e., invasive fetal scalp ECG). The performance parameters of the FQRS detector such as sensitivity (Se), positive predictive value (PPV), and accuracy (F 1 ) were found to improve even for lower filter order. The same technique was extended to evaluate maternal QRS detector (MQRS) and found to yield satisfactory maternal heart rate (MHR) results.
... or, later in pregnancy, give you an electronic fetal non-stress test. This involves lying on your back with electronic monitors attached to your abdomen. The monitors record the baby's heart rate, movements, and contractions of the uterus. Why Do ...
Treatment of Sleep Disordered Breathing Reverses Low Fetal Activity Levels in Preeclampsia
Blyton, Diane M.; Skilton, Michael R.; Edwards, Natalie; Hennessy, Annemarie; Celermajer, David S.; Sullivan, Colin E.
2013-01-01
Study Objectives: Preeclampsia affects 5% to 7% of pregnancies, is strongly associated with low birth weight and fetal death, and is accompanied by sleep disordered breathing. We hypothesized that sleep disordered breathing may link preeclampsia with reduced fetal movements (a marker of fetal health), and that treatment of sleep disordered breathing might improve fetal activity during sleep. Design, Setting, and Participants: First, a method of fetal movement recording was validated against ultrasound in 20 normal third trimester pregnancies. Second, fetal movement was measured overnight with concurrent polysomnography in 20 patients with preeclampsia and 20 control subjects during third trimester. Third, simultaneous polysomnography and fetal monitoring was done in 10 additional patients with preeclampsia during a control night and during a night of nasal CPAP. Intervention: Overnight continuous positive airway pressure. Measurements and Results: Women with preeclampsia had inspiratory flow limitation and an increased number of oxygen desaturations during sleep (P = 0.008), particularly during REM sleep. Preeclampsia was associated with reduced total fetal movements overnight (319 [SD 32]) versus controls (689 [SD 160], P < 0.0001) and a change in fetal movement patterns. The number of fetal hiccups was also substantially reduced in preeclampsia subjects (P < 0.0001). Continuous positive airway pressure treatment increased the number of fetal movements and hiccups (P < 0.0001 and P = 0.0002, respectively). Conclusions: The effectiveness of continuous positive airway pressure in improving fetal movements suggests a pathogenetic role for sleep disordered breathing in the reduced fetal activity and possibly in the poorer fetal outcomes associated with preeclampsia. Citation: Blyton DM; Skilton MR; Edwards N; Hennessy A; Celermajer DS; Sullivan CE. Treatment of sleep disordered breathing reverses low fetal activity levels in preeclampsia. SLEEP 2013;36(1):15–21. PMID:23288967
Miller, Lisa A; Miller, David A
2013-01-01
Intrapartum electronic fetal monitoring (EFM) is one of the most common procedures in obstetrics. Current consensus statements provide clinicians with a common language for EFM as well as provide a basis for a simplified approach to interpretation and management. This article presents a summary of the content and implementation of a statewide initiative in interdisciplinary EFM education and training designed to give clinicians of all backgrounds a shared mental model in EFM. Challenges to implementation at individual institutions may include physician and nursing engagement as well as time and cost constraints.
Optoacoustic measurements of human placenta and umbilical blood oxygenation
NASA Astrophysics Data System (ADS)
Nanovskaya, T. N.; Petrov, I. Y.; Petrov, Y.; Patrikeeva, S. L.; Ahmed, M. S.; Hankins, G. D. V.; Prough, D. S.; Esenaliev, R. O.
2016-03-01
Adequate oxygenation is essential for normal embryogenesis and fetal growth. Perturbations in the intrauterine oxidative environment during pregnancy are associated with several pathophysiological disorders such as pregnancy loss, preeclampsia, and intrauterine growth restriction. We proposed to use optoacoustic technology for monitoring placental and fetal umbilical blood oxygenation. In this work, we studied optoacoustic monitoring of oxygenation in placenta and umbilical cord blood ex vivo using technique of placenta perfusion. We used a medical grade, nearinfrared, tunable, optoacoustic system developed and built for oxygenation monitoring in blood vessels and in tissues. First, we calibrated the system for cord blood oxygenation measurements by using a CO-Oximeter (gold standard). Then we performed validation in cord blood circulating through the catheters localized on the fetal side of an isolated placental lobule. Finally, the oxygenation measurements were performed in the perfused placental tissue. To increase or decrease blood oxygenation, we used infusion of a gas mixture of 95% O2 + 5% CO2 and 95% N2 + 5% CO2, respectively. In placental tissue, up to four cycles of changes in oxygenation were performed. The optoacoustically measured oxygenation in circulating cord blood and in placental lobule closely correlated with the actual oxygenation data measured by CO-Oximeter. We plan to further test the placental and cord blood oxygenation monitoring with optoacoustics in animal and clinical studies.
Kisilevsky, Barbara S; Brown, C Ann
2016-02-01
To determine the reliability at term of: (1) two methods of measuring fetal heart rate (HR), electrocardiographic (ECG, the 'gold standard') and cardiotocographic (CTG) and (2) two ECG methods of measuring maternal HR variability over relatively brief periods of time (s-min). During 20 min of rest (N=39) and during 2 min of auditory stimulation (mother's recorded voice, n=19), fetal HR data were collected using an ECG (Monica AN24) and a Hewlett-Packard Model 1351A CTG. Simultaneously, maternal HR data (n=37) were collected using the same ECG device (Monica AN24) and a second stand-alone cardiac monitor (Spacelab 514T cardiac monitor with a QRS detector). During 20 min of maternal rest, correlations of individual fetal CTG with ECG measures of HR at each second were moderate to high (r=.57-.97) for 77% of fetuses. Correlations of HR averaged over fetuses and over each of the 20 min were high (r=.93-.97); fetal HR averaged over 20 min varied between devices from 0.0 to 0.8 bpm. During 2 min of maternal voice presentation, correlations of fetal HR over each second were moderate to high (r=.54-.99) for 95% of fetuses and high (all rs=.99) when averaged across fetuses in 30s or 2 min epochs. Average fetal HR between devices over the 2 min voice varied from 0.0 to 0.6 bpm. Correlations and/or % agreement between the two ECG methods of measuring maternal HR were high. Average maternal HR over 10 min showed 81% of pairs with a difference of ≤ 1 bpm; correlations for HR variability measures varied from r=.89 to .97. Good reliability was demonstrated between individual spontaneous and auditory induced fetal CTG and ECG with high correlations when HR data were averaged over fetuses or in 30-120 s epochs. High reliability of maternal HR measures was obtained using two ECG devices. Copyright © 2016 Elsevier Inc. All rights reserved.
Fetal heart rate monitoring of short term variation (STV): a methodological observational study.
Wretler, Stina; Holzmann, Malin; Graner, Sophie; Lindqvist, Pelle; Falck, Susanne; Nordström, Lennart
2016-03-16
Cardiotocography (CTG) has high sensitivity, but less specificity in detection of fetal hypoxia. There is need for adjunctive methods easy to apply during labor. Low fetal heart rate short term variation (STV) is predictive for hypoxia during the antenatal period. The objectives of our study were to methodologically evaluate monitoring of STV during labor and to compare two different monitors (Sonicaid™ and EDAN™) for antenatal use. A prospective observational study at the obstetric department, Karolinska University hospital, Stockholm (between September 2011 and April 2015). In 100 women of ≥ 36 weeks gestation, STV values were calculated during active labor. In a subset of 20 women we compared STV values between internal and external signal acquisition. Additionally we compared antenatal monitoring with two different monitors in another 20 women. Median STV in 100 fetuses monitored with scalp electrode during labor (EDAN™) was 7.1 msec (range 1.3-25.9) with no difference between early (3-6 cm) and late (7-10 cm) labor (7.1 vs 6.8 msec; p = 0.80). STV calculated from scalp electrode signals were positively correlated with delta-STV (STV internal -external) (R = 0.70; p < 0.01). No significant differences were found between Sonicaid™ and EDAN™ in antenatal external monitoring of STV (median difference 0.9 msec, Spearman Rank Correlation Sonicaid vs delta-STV; R = 0.35; p = 0.14). Median intrapartum STV was 7.1 msec. Significant differences were found between internal and external signal acquisition, a finding that suggests further intrapartum studies to be analysed separately depending upon type of signal acquisition. Antenatal external monitoring with Sonicaid™ and EDAN™ indicates that the devices perform equally well in the identification of acidemic fetuses. Further studies are needed to assess the clinical value of intrapartum STV.
Biomedical Instruments for Fetal and Neonatal Surveillance
NASA Astrophysics Data System (ADS)
Rolfe, P.; Scopesi, F.; Serra, G.
2006-10-01
Specialised instruments have been developed to aid the care of the fetus and the newborn baby. Miniature sensors using optical, electrical, chemical, mechanical and magnetic principles have been produced for capturing key measurands. These include temperature, pressure, flow and dimension, as well as several specific molecules such as glucose, oxygen and carbon dioxide. During pregnancy ultrasound imaging and blood flow techniques provide valuable information concerning fetal abnormalities, fetal growth, fetal breathing and fetal heart rate. Signal processing and pattern recognition can be useful for deriving indicators of fetal distress and clinical status, based on biopotentials as well as ultrasound signals. Fetal pH measurement is a critical requirement during labour and delivery. The intensive care of ill preterm babies involves provision of an optimal thermal environment and respiratory support. Monitoring of blood gas and acid-base status is essential, and this involves both blood sampling for in vitro analysis as well as the use of invasive or non-invasive sensors. For the future it will be vital that the technologies used are subjected to controlled trials to establish benefit or otherwise.
[Ultrasound in monitoring of the second stage of labour].
Fouché, C J; Simon, E G; Potin, J; Perrotin, F
2012-11-01
In the second stage of labor, fetal head rotation and fetal head position are determinant for the management of labor to attempt a vaginal delivery or a cesarean section. However, digital examination is highly subjective. Nowadays, delivery rooms are often equipped with compact and high performance ultrasound systems. The clinical examination can be easily completed by quantified and reproducible methods. Transabdominal ultrasonography is a well-known and efficient way to determine the fetal head position. Nevertheless, ultrasound approach to assess fetal head descent is less widespread. We can use translabial or transperineal way to evaluate fetal head position. We describe precisely two different types of methods: the linear methods (3 different types) and the angles of progression (4 different types of measurement). Among all those methods, the main pelvic landmarks are the symphysis pubis and the fetal skull. The angle of progression appears promising but the assessment was restricted to occipitoanterior fetal position cases. In the coming years, ultrasound will likely play a greater role in the management of labor. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Fetal motion estimation from noninvasive cardiac signal recordings.
Biglari, Hadis; Sameni, Reza
2016-11-01
Fetal motility is a widely accepted indicator of the well-being of a fetus. In previous research, it has be shown that fetal motion (FM) is coherent with fetal heart rate accelerations and an indicator for active/rest cycles of the fetus. The most common approach for FM and fetal heart rate (FHR) assessment is by Doppler ultrasound (DUS). While DUS is the most common approach for studying the mechanical activities of the heart, noninvasive fetal electrocardiogram (ECG) and magnetocardiogram (MCG) recording and processing techniques have been considered as a possible competitor (or complement) for the DUS. In this study, a fully automatic and robust framework is proposed for the extraction, ranking and alignment of fetal QRS-complexes from noninvasive fetal ECG/MCG. Using notions from subspace tracking, two measures, namely the actogram and rotatogram, are defined for fetal motion tracking. The method is applied to four fetal ECG/MCG databases, including twin MCG recordings. By defining a novel measure of causality, it is shown that there is significant coherency and causal relationship between the actogram/rotatogram and FHR accelerations/decelerations. Using this measure, it is shown that in many cases, the actogram and rotatogram precede the FHR variations, which supports the idea of motion-induced FHR accelerations/decelerations for these cases and raises attention for the non-motion-induced FHR variations, which can be associated to the fetal central nervous system developments. The results of this study can lead to novel perspectives of the fetal sympathetic and parasympathetic brain systems and future requirements of fetal cardiac monitoring.
Hayashi, Risa; Nakai, Kenji; Fukushima, Akimune; Itoh, Manabu; Sugiyama, Toru
2009-03-01
Although ultrasonic diagnostic imaging and fetal heart monitors have undergone great technological improvements, the development and use of fetal electrocardiograms to evaluate fetal arrhythmias and autonomic nervous activity have not been fully established. We verified the clinical significance of the novel signal-averaged vector-projected high amplification ECG (SAVP-ECG) method in fetuses from 48 gravidas at 32-41 weeks of gestation and in 34 neonates. SAVP-ECGs from fetuses and newborns were recorded using a modified XYZ-leads system. Once noise and maternal QRS waves were removed, the P, QRS, and T wave intervals were measured from the signal-averaged fetal ECGs. We also compared fetal and neonatal heart rates (HRs), coefficients of variation of heart rate variability (CV) as a parasympathetic nervous activity, and the ratio of low to high frequency (LF/HF ratio) as a sympathetic nervous activity. The rate of detection of a fetal ECG by SAVP-ECG was 72.9%, and the fetal and neonatal QRS and QTc intervals were not significantly different. The neonatal CVs and LF/HF ratios were significantly increased compared with those in the fetus. In conclusion, we have developed a fetal ECG recording method using the SAVP-ECG system, which we used to evaluate autonomic nervous system development.
Fetal growth velocity and body proportion in the assessment of growth.
Hiersch, Liran; Melamed, Nir
2018-02-01
Fetal growth restriction implies failure of a fetus to meet its growth potential and is associated with increased perinatal mortality and morbidity. Therefore, antenatal detection of fetal growth restriction is of major importance in an attempt to deliver improved clinical outcomes. The most commonly used approach towards screening for fetal growth restriction is by means of sonographic fetal weight estimation, to detect fetuses small for gestational age, defined by an estimated fetal weight <10th percentile for gestational age. However, the predictive accuracy of this approach is limited both by suboptimal detection rate (as it may overlook non-small-for-gestational-age growth-restricted fetuses) and by a high false-positive rate (as most small-for-gestational-age fetuses are not growth restricted). Here, we review 2 strategies that may improve the diagnostic accuracy of sonographic fetal biometry for fetal growth restriction. The first strategy involves serial ultrasound evaluations of fetal biometry. The information obtained through these serial assessments can be interpreted using several different approaches including fetal growth velocity, conditional percentiles, projection-based methods, and individualized growth assessment that can be viewed as mathematical techniques to quantify any decrease in estimated fetal weight percentile, a phenomenon that many care providers assess and monitor routinely in a qualitative manner. This strategy appears promising in high-risk pregnancies where it seems to improve the detection of growth-restricted fetuses at increased risk of adverse perinatal outcomes and, at the same time, decrease the risk of falsely diagnosing healthy constitutionally small-for-gestational-age fetuses as growth restricted. Further studies are needed to determine the utility of this strategy in low-risk pregnancies as well as to optimize its performance by determining the optimal timing and interval between exams. The second strategy refers to the use of fetal body proportions to classify fetuses as either symmetric or asymmetric using 1 of several ratios; these include the head circumference to abdominal circumference ratio, transverse cerebellar diameter to abdominal circumference ratio, and femur length to abdominal circumference ratio. Although these ratios are associated with small for gestational age at birth and with adverse perinatal outcomes, their predictive accuracy is too low for clinical practice. Furthermore, these associations become questionable when other, potentially more specific measures such as umbilical artery Doppler are being used. Furthermore, these ratios are of limited use in determining the etiology underlying fetal smallness. It is possible that the use of the 2 gestational-age-independent ratios (transverse cerebellar diameter to abdominal circumference and femur length to abdominal circumference) may have a role in the detection of mild-moderate fetal growth restriction in pregnancies without adequate dating. In addition, despite their limited predictive accuracy, these ratios may become abnormal early in the course of fetal growth restriction and may therefore identify pregnancies that may benefit from closer monitoring of fetal growth. Copyright © 2017 Elsevier Inc. All rights reserved.
Brown, James; McIntyre, Andrew; Gasparotto, Robyn; McGee, Therese M
2016-06-01
Many birth units use central fetal monitoring (CFM) under the assumption that greater surveillance improves perinatal outcomes. The unexpected loss of the CFM system at a tertiary unit provided a unique opportunity to evaluate outcomes and staff attitudes toward CFM. This retrospective cohort study compared patient data from 2,855 electronically monitored women delivering over a 12-month period, where CFM was available for the first 6 months but unavailable for the following 6 months. Primary outcomes relating to neonatal morbidity and secondary outcomes relating to intrapartum interventions were examined. Additionally, birth unit staff members were surveyed about aspects of care related to CFM. There were no significant differences in perinatal outcomes between the cohorts. While unadjusted analysis suggested a lower spontaneous vaginal birth rate (55.4% vs 60.3%) and a higher cesarean delivery rate (25.1% vs 22.0%, p = 0.026), together with higher epidural (53.0% vs 49.2%, p = 0.04) and fetal blood sampling (11.8% vs 9.4%, p = 0.03) rates in the presence of CFM, these differences were lost when adjusted for prostaglandin ripening. Over half of the staff (56.0% of midwives, 54.0% of obstetricians) reported spending more time with the laboring woman in the period without CFM. This single institution's experience indicates that in birth units staffed for one-to-one care in labor, central fetal monitoring does not appear to be associated with either a benefit on perinatal outcomes or an increase in cesarean delivery and other interventions. However, it is associated with a reduction in the time a midwife spends with the laboring woman. © 2016 Wiley Periodicals, Inc.
[Intrapartum amnioinfusion in patients with meconium-stained amniotic fluid].
Engel, Karina; Samborska, Monika; Bilar, Marek; Sipak-Szmigiel, Olimpia; Ronin-Walknowska, Elzbieta
2008-09-01
The aim of the study was to evaluate the effect of intrapartum amnioinfusion in the presence of meconium stained amniotic fluid. 93 women with meconium-stained amniotic fluid were assigned to receive amnioinfusion or no amnioinfusion (128 women). The trials were evaluated for fetal distress syndrome, route of delivery, fetal acidemia, Apgar score at 1 and 5 min., meconium aspiration syndrome, postpartum endometritis and maternal hospital stays. Amnioinfusion in cases of meconium-stained fluid did not improve the number of fetal distress symptoms during fetal heart rate monitoring. Amnioinfusion was associated with a significant decrease of neonatal acidemia although it did not improve Apgar score. In our study amnioinfusion was not associated with reduction in the incidence of neonatal outcome and puerperial complications.
Maternal exercise, season and sex modify the daily fetal heart rate rhythm.
Sletten, J; Cornelissen, G; Assmus, J; Kiserud, T; Albrechtsen, S; Kessler, J
2018-05-13
The knowledge on biological rhythms is rapidly expanding. We aimed to define the longitudinal development of the daily (24-hour) fetal heart rate rhythm in an unrestricted, out-of-hospital setting and to examine the effects of maternal physical activity, season and fetal sex. We recruited 48 women with low-risk singleton pregnancies. Using a portable monitor for continuous fetal electrocardiography, fetal heart rate recordings were obtained around gestational weeks 24, 28, 32 and 36. Daily rhythms in fetal heart rate and fetal heart rate variation were detected by cosinor analysis; developmental trends were calculated by population-mean cosinor and multilevel analysis. For the fetal heart rate and fetal heart rate variation, a significant daily rhythm was present in 122/123 (99.2%) and 116/121 (95.9%) of the individual recordings respectively. The rhythms were best described by combining cosine waves with periods of 24 and 8 hours. With increasing gestational age, the magnitude of the fetal heart rate rhythm increased, and the peak of the fetal heart rate variation rhythm shifted from a mean of 14:25 (24 weeks) to 20:52 (36 weeks). With advancing gestation, the rhythm-adjusted mean value of the fetal heart rate decreased linearly in females (P < .001) and nonlinearly in males (quadratic function, P = .001). At 32 and 36 weeks, interindividual rhythm diversity was found in male fetuses during higher maternal physical activity and during the summer season. The dynamic development of the daily fetal heart rate rhythm during the second half of pregnancy is modified by fetal sex, maternal physical activity and season. © 2018 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.
Biotelemeters for Space Flights and Fetal Monitoring
NASA Technical Reports Server (NTRS)
Mundt, Carsten W.; Ricks, Robert D.; Hines, John W.
1999-01-01
Pill-shaped biotelemeters originally designed for space flight applications will soon be used for monitoring the health of a fetus during and after in-utero fetal surgery. The authors developed a family of biotelemeters that are not only small enough for rodent studies on board the space shuttle or international space station, but also fit through a 10 mm trocar, a plastic tube that is used in endoscopic fetal surgery to obtain minimally invasive access to the fetus. The first 'pill' measures pressure and temperature, and is currently undergoing long-term leakage and biocompatibility tests. A second pill under development measures pH and temperature. A prototype of the 'pH-pill' has been built and successfully tested and is presently being miniaturized into the same dimensions as the 'pressure pill'. Additional pills measuring heart rate, ECG, other ions such as calcium and potassium, and eventually glucose and blood gases, will follow. All pills are designed for ultra-low power consumption yielding lifetimes of up to 10 months in order to meet the requirements of fetal monitoring, but also to provide the capability of long-term space station experiments. Each pill transmits its pulse-interval-modulated signal on a unique carrier frequency in the frequency range of 174-216MHz. A custom-designed multi-channel receiver demodulates and decodes each pill signal and sends the data to a LabVIEW program that performs real-time data analysis and display. A patent for the pill family and its data analysis system is pending.
Fetal Heart Rate Monitoring during Intrauterine Open Surgery for Myelomeningocele Repair.
Santana, Eduardo Félix Martins; Moron, Antônio Fernandes; Barbosa, Maurício Mendes; Milani, Herbene Jose Figuinha; Sarmento, Stephanno Gomes Pereira; Araujo Júnior, Edward; Rolo, Liliam Cristine; Cavalheiro, Sérgio
2016-01-01
The aim of this study was to assess fetal hemodynamics during intrauterine open surgery for myelomeningocele (MMC) repair by describing fetal heart rate (FHR) monitoring in detail related to each part of the procedure. A study was performed with 57 fetuses submitted to intrauterine MMC repair between the 24th and 27th week of gestation. Evaluations of FHR were made in specific periods: before anesthesia, after anesthesia, at the beginning of laparotomy, during uterus abdominal withdrawal, hysterotomy, neurosurgery (before incision, during early skin manipulation, spinal cord releasing, and at the end of neurosurgery), abdominal cavity reintroduction, and abdominal closure, and at the end of surgery. Means ± standard deviations of FHR were established for each period, and analysis of variance with repeated measures was used to assess differences between these periods. The mean differences were assessed with 95% confidence intervals and were analyzed by Tukey's multiple comparison test. The mean FHR during the specific periods mentioned above was 140.2, 140, 139.2, 138.8, 135.1, 133.9, 123.1, 134.0, 134.5, 137.9, and 139.9 bpm, respectively (p < 0.0001). Comparing the different periods, the highest frequencies were observed in the initial and final moments. The neurosurgery stage presents lower frequencies, especially during the release of the spinal cord. FHR monitoring revealed interesting findings in terms of physiological fetal changes during MMC repair, especially during neurosurgery, which was the most critical period. © 2015 S. Karger AG, Basel.
Fetal well-being: nonimaging assessment and the biophysical profile.
Jackson, G M; Forouzan, I; Cohen, A W
1991-01-01
All of the testing methods described above are very good at predicting continued fetal health when test results are reassuring. Each test also suffers from a very poor ability to predict compromise when results are abnormal. Thus, the primary value of antepartum fetal monitoring is in identifying those pregnancies that do not require immediate intervention and may be allowed to continue. Certainly, all pregnant women (regardless of risk status) should monitor fetal movement as part of their fetal surveillance. For patients at risk, a variety of testing schemes are available using combinations of the NST, CST and BPP. There are several reasons for using the NST as the primary testing method for those at risk. Even a small antenatal testing area can accommodate three or four FHR monitors, and a single antenatal testing nurse can perform several NSTs at a time. Because the BPP requires an ultrasound machine and a trained technician to perform, and because only one BPP can be done at a time, many obstetricians who do their own in-office fetal testing are unable to adopt BPP testing as their primary means of surveillance. Additionally, it is more economical to use the NST than the BPP for first-line testing. Assuming charges of $150 and $300 for the NST and BPP, respectively, and assuming that 20% of NSTs are nonreactive and require a BPP for second-line testing, the weekly cost of testing 100 patients is $21,000 for the NST and $37,500 for the BPP. This increase-in-testing cost must be balanced against the small improvement in perinatal mortality rates achieved with the use of the BPP. Because it must be performed in a hospital setting and takes an average of 90 minutes to complete, the CST is more expensive and time-consuming than either the NST or BPP and it is less frequently used as the primary method of fetal testing. In the past the CST was the most commonly used secondary test after a nonreactive NST, but use of the BPP in this situation has now become commonplace. Although the CST still has an important role in fetal testing, the BPP is better suited for use in this setting because of its technical ease and low incidence of abnormal results. Thus, many centers use the NST as the primary mode of testing for the fetus at risk, often with a sonographic assessment of AFV.(ABSTRACT TRUNCATED AT 400 WORDS)
Eden, Robert D; Evans, Mark I; Evans, Shara M; Schifrin, Barry S
2018-01-01
Electronic fetal monitoring (EFM) correlates poorly with neonatal outcome. We present a new metric: the "Fetal Reserve Index" (FRI), formally incorporating EFM with maternal, obstetrical, fetal risk factors, and excessive uterine activity for assessment of risk for cerebral palsy (CP). We performed a retrospective, case-control series of 50 term CP cases with apparent intrapartum neurological injury and 200 controls. All were deemed neurologically normal on admission. We compared the FRI against ACOG Category (I-III) system and long-term outcome parameters against ACOG monograph (NEACP) requirements for labor-induced fetal neurological injury. Abnormal FRI's identified 100% of CP cases and did so hours before injury. ACOG Category III identified only 44% and much later. Retrospective ACOG monograph criteria were found in at most 30% of intrapartum-acquired CP patients; only 27% had umbilical or neonatal pH <7.0. In this initial, retrospective trial, an abnormal FRI identified all cases of labor-related neurological injury more reliably and earlier than Category III, which may allow fetal therapy by intrauterine resuscitation. The combination of traditional EFM with maternal, obstetrical, and fetal risk factors creating the FRI performed much better as a screening test than EFM alone. Our quantified screening system needs further evaluation in prospective trials. © 2017 S. Karger AG, Basel.
Fetal QRS detection and heart rate estimation: a wavelet-based approach.
Almeida, Rute; Gonçalves, Hernâni; Bernardes, João; Rocha, Ana Paula
2014-08-01
Fetal heart rate monitoring is used for pregnancy surveillance in obstetric units all over the world but in spite of recent advances in analysis methods, there are still inherent technical limitations that bound its contribution to the improvement of perinatal indicators. In this work, a previously published wavelet transform based QRS detector, validated over standard electrocardiogram (ECG) databases, is adapted to fetal QRS detection over abdominal fetal ECG. Maternal ECG waves were first located using the original detector and afterwards a version with parameters adapted for fetal physiology was applied to detect fetal QRS, excluding signal singularities associated with maternal heartbeats. Single lead (SL) based marks were combined in a single annotator with post processing rules (SLR) from which fetal RR and fetal heart rate (FHR) measures can be computed. Data from PhysioNet with reference fetal QRS locations was considered for validation, with SLR outperforming SL including ICA based detections. The error in estimated FHR using SLR was lower than 20 bpm for more than 80% of the processed files. The median error in 1 min based FHR estimation was 0.13 bpm, with a correlation between reference and estimated FHR of 0.48, which increased to 0.73 when considering only records for which estimated FHR > 110 bpm. This allows us to conclude that the proposed methodology is able to provide a clinically useful estimation of the FHR.
Wavelet-Based Adaptive Denoising of Phonocardiographic Records
2001-10-25
phonocardiography, including the recording of fetal heart sounds on the maternal abdominal surface. Keywords - phonocardiography, wavelets, denoising, signal... fetal heart rate monitoring [2], [7], [8]. Unfortunately, heart sound records are very often disturbed by various factors, which can prohibit their...recorded the acoustic signals. The first microphone was inserted into the focus of a stethoscope and it recorded the acoustic signals of the heart ( heart
Effects of hypercapnia and hypoxemia on fetal breathing after decortication.
Ioffe, S; Jansen, A H; Chernick, V
1986-09-01
The effects of hypercapnia and hypoxemia on breathing movements were studied in 12 chronically decorticated fetal sheep, 127-140 days gestation. The fetal state of consciousness was defined in terms of activity of the lateral rectus and nuchal muscles. Arterial blood pressure was monitored. Fetal breathing was determined by integrated diaphragmatic electromyogram (EMG) and analyzed in terms of inspiratory time (TI), expiratory time (TE), electrical equivalent of tidal volume (EVT), breath interval (TT), duty cycle (TI/TT), mean inspiratory flow equivalent (EVT/TI), and instantaneous ventilation equivalent (EVT/TT). Fetal breathing occurred only during episodes of rapid-eye movements, and the response to hypercapnia consisted of an increase in EVT, TI, EVE, and EVT/TI and a decrease in the coefficient of variation of all measured parameters. Induction of hypoxia during episodes of spontaneous fetal breathing produced a decrease in the rate of breathing and an increase in EVT and TI with no change in the variability of all parameters studied. Since similar responses to hypercapnia and hypoxemia are seen in the intact fetus, we conclude that the cerebral cortex has no obvious effect on the chemical control of fetal breathing.
Gestational and Fetal Outcomes in B19 Maternal Infection: a Problem of Diagnosis▿
Bonvicini, Francesca; Puccetti, Chiara; Salfi, Nunzio C. M.; Guerra, Brunella; Gallinella, Giorgio; Rizzo, Nicola; Zerbini, Marialuisa
2011-01-01
Parvovirus B19 infection during pregnancy is a potential hazard to the fetus because of the virus' ability to infect fetal erythroid precursor cells and fetal tissues. Fetal complications range from transitory fetal anemia and nonimmune fetal hydrops to miscarriage and intrauterine fetal death. In the present study, 72 pregnancies complicated by parvovirus B19 infection were followed up: fetal and neonatal specimens were investigated by serological and/or virological assays to detect fetal/congenital infection, and fetuses and neonates were clinically evaluated to monitor pregnancy outcomes following maternal infection. Analysis of serological and virological maternal B19 markers of infection demonstrated that neither B19 IgM nor B19 DNA detected all maternal infections. IgM serology correctly diagnosed 94.1% of the B19 infections, while DNA testing correctly diagnosed 96.3%. The maximum sensitivity was achieved with the combined detection of both parameters. B19 vertical transmission was observed in 39% of the pregnancies, with an overall 10.2% rate of fetal deaths. The highest rates of congenital infections and B19-related fatal outcomes were observed when maternal infections occurred by the gestational week 20. B19 fetal hydrops occurred in 11.9% of the fetuses, and 28.6% resolved the hydrops with a normal neurodevelopment outcome at 1- to 5-year follow-up. In conclusion, maternal screening based on the concurrent analysis of B19 IgM and DNA should be encouraged to reliably diagnose maternal B19 infection and correctly manage pregnancies at risk. PMID:21849687
Kiserud, Torvid; Benachi, Alexandra; Hecher, Kurt; Perez, Rogelio González; Carvalho, José; Piaggio, Gilda; Platt, Lawrence D
2018-02-01
Ultrasound biometry is an important clinical tool for the identification, monitoring, and management of fetal growth restriction and development of macrosomia. This is even truer in populations in which perinatal morbidity and mortality rates are high, which is a reason that much effort is put onto making the technique available everywhere, including low-income societies. Until recently, however, commonly used reference ranges were based on single populations largely from industrialized countries. Thus, the World Health Organization prioritized the establishment of fetal growth charts for international use. New fetal growth charts for common fetal measurements and estimated fetal weight were based on a longitudinal study of 1387 low-risk pregnant women from 10 countries (Argentina, Brazil, Democratic Republic of Congo, Denmark, Egypt, France, Germany, India, Norway, and Thailand) that provided 8203 sets of ultrasound measurements. The participants were characterized by median age 28 years, 58% nulliparous, normal body mass index, with no socioeconomic or nutritional constraints (median caloric intake, 1840 calories/day), and had the ability to attend the ultrasound sessions, thus essentially representing urban populations. Median gestational age at birth was 39 weeks, and birthweight was 3300 g, both with significant differences among countries. Quantile regression was used to establish the fetal growth charts, which also made it possible to demonstrate a number of features of fetal growth that previously were not well appreciated or unknown: (1) There was an asymmetric distribution of estimated fetal weight in the population. During early second trimester, the distribution was wider among fetuses <50th percentile compared with those above. The pattern was reversed in the third trimester, with a notably wider variation >50th percentile. (2) Although fetal sex, maternal factors (height, weight, age, and parity), and country had significant influence on fetal weight (1-4.5% each), their effect was graded across the percentiles. For example, the positive effect of maternal height on fetal weight was strongest on the lowest percentiles and smallest on the highest percentiles for estimated fetal weight. (3) When adjustment was made for maternal covariates, there was still a significant effect of country as covariate that indicated that ethnic, cultural, and geographic variation play a role. (4) Variation between populations was not restricted to fetal size because there were also differences in growth trajectories. (5) The wide physiologic ranges, as illustrated by the 5th-95th percentile for estimated fetal weight being 2205-3538 g at 37 weeks gestation, signify that human fetal growth under optimized maternal conditions is not uniform. Rather, it has a remarkable variation that largely is unexplained by commonly known factors. We suggest this variation could be part of our common biologic strategy that makes human evolution extremely successful. The World Health Organization fetal growth charts are intended to be used internationally based on low-risk pregnancies from populations in Africa, Asia, Europe, and South America. We consider it prudent to test and monitor whether the growth charts' performance meets the local needs, because refinements are possible by a change in cut-offs or customization for fetal sex, maternal factors, and populations. In the same line, the study finding of variations emphasizes the need for carefully adjusted growth charts that reflect optimal local growth when public health issues are addressed. Copyright © 2017 Elsevier Inc. All rights reserved.
Martinek, Radek; Kelnar, Michal; Koudelka, Petr; Vanus, Jan; Bilik, Petr; Janku, Petr; Nazeran, Homer; Zidek, Jan
2016-02-01
This paper describes the design, construction, and testing of a multi-channel fetal electrocardiogram (fECG) signal generator based on LabVIEW. Special attention is paid to the fetal heart development in relation to the fetus' anatomy, physiology, and pathology. The non-invasive signal generator enables many parameters to be set, including fetal heart rate (FHR), maternal heart rate (MHR), gestational age (GA), fECG interferences (biological and technical artifacts), as well as other fECG signal characteristics. Furthermore, based on the change in the FHR and in the T wave-to-QRS complex ratio (T/QRS), the generator enables manifestations of hypoxic states (hypoxemia, hypoxia, and asphyxia) to be monitored while complying with clinical recommendations for classifications in cardiotocography (CTG) and fECG ST segment analysis (STAN). The generator can also produce synthetic signals with defined properties for 6 input leads (4 abdominal and 2 thoracic). Such signals are well suited to the testing of new and existing methods of fECG processing and are effective in suppressing maternal ECG while non-invasively monitoring abdominal fECG. They may also contribute to the development of a new diagnostic method, which may be referred to as non-invasive trans-abdominal CTG + STAN. The functional prototype is based on virtual instrumentation using the LabVIEW developmental environment and its associated data acquisition measurement cards (DAQmx). The generator also makes it possible to create synthetic signals and measure actual fetal and maternal ECGs by means of bioelectrodes.
Gonçalves, Hernâni; Pinto, Paula; Silva, Manuela; Ayres-de-Campos, Diogo; Bernardes, João
2016-04-01
Fetal heart rate (FHR) monitoring is used routinely in labor, but conventional methods have a limited capacity to detect fetal hypoxia/acidosis. An exploratory study was performed on the simultaneous assessment of maternal heart rate (MHR) and FHR variability, to evaluate their evolution during labor and their capacity to detect newborn acidemia. MHR and FHR were simultaneously recorded in 51 singleton term pregnancies during the last two hours of labor and compared with newborn umbilical artery blood (UAB) pH. Linear/nonlinear indices were computed separately for MHR and FHR. Interaction between MHR and FHR was quantified through the same indices on FHR-MHR and through their correlation and cross-entropy. Univariate and bivariate statistical analysis included nonparametric confidence intervals and statistical tests, receiver operating characteristic curves and linear discriminant analysis. Progression of labor was associated with a significant increase in most MHR and FHR linear indices, whereas entropy indices decreased. FHR alone and in combination with MHR as FHR-MHR evidenced the highest auROC values for prediction of fetal acidemia, with 0.76 and 0.88 for the UAB pH thresholds 7.20 and 7.15, respectively. The inclusion of MHR on bivariate analysis achieved sensitivity and specificity values of nearly 100 and 89.1%, respectively. These results suggest that simultaneous analysis of MHR and FHR may improve the identification of fetal acidemia compared with FHR alone, namely during the last hour of labor.
Acute behavioral effects of intrapleural OK-432 (Picibanil) administration in preterm fetal sheep.
Cowie, Rosalind V; Stone, Peter R; Parry, Emma; Jensen, Ellen C; Gunn, Alistair J; Bennet, Laura
2009-01-01
To develop a model to study the fetal effects of intrapleural infusion of OK-432 (Picibanil), a pleurodesis agent derived from killed Gram-positive streptococci. OK-432 (0.1 mg, n = 5), or normal saline (n = 5) were infused over 20 min into the pleural space of chronically instrumented preterm fetal sheep at 0.7 gestation. Fetal physiological parameters, including breathing and nuchal activity were monitored in utero from 6 h before infusion until 12 h afterward, and fetuses were killed after 7 days recovery. OK-432 was associated with transient suppression of fetal EEG activity, breathing and body movements from 3-6 h after infusion. Hypotension and hypoxia did not occur. At postmortem, local pleural adhesions were seen around the site of OK-432 infusion but not in saline treated fetuses. Intrapleural administration of OK-432 is associated with marked but transient fetal behavioral effects. This model will enable preclinical investigation of the neural and cardiovascular safety of OK-432 at a clinical relevant stage of development. Copyright 2009 S. Karger AG, Basel.
STUDIES IN FETAL BEHAVIOR: REVISITED, RENEWED, AND REIMAGINED.
DiPietro, Janet A; Costigan, Kathleen A; Voegtline, Kristin M
2015-09-01
Among the earliest volumes of this monograph series was a report by Lester Sontag and colleagues, of the esteemed Fels Institute, on the heart rate of the human fetus as an expression of the developing nervous system. Here, some 75 years later, we commemorate this work and provide historical and contemporary context on knowledge regarding fetal development, as well as results from our own research. These are based on synchronized monitoring of maternal and fetal parameters assessed between 24 and 36 weeks gestation on 740 maternal-fetal pairs compiled from eight separate longitudinal studies, which commenced in the early 1990s. Data include maternal heart rate, respiratory sinus arrhythmia, and electrodrmal activity and fetal heartrate, motor activity, and their integration. Hierarchical linear modeling of developmental trajectories reveals that the fetus develops in predictable ways consistent with advancing parasympathetic regulation. Findings also include:within-fetus stability (i.e., preservation of rank ordering over time) for heart rate, motor, and coupling measures; a transitional period of decelerating development near 30 weeks gestation; sex differences in fetal heart rate measures but not in most fetal motor activity measures; modest correspondence in fetal neurodevelopment among siblings as compared to unrelated fetuses; and deviations from normative fetal development in fetuses affected by intrauterine growth restriction and other conditions. Maternal parameters also change during this period of gestation and there is evidence that fetal sex and individual variation in fetal neurobehavior influence maternal physio-logical processes and the local intrauterine context. Results are discussed within the framework of neuromaturation, the emergence of individual differences, and the bidirectional nature of the maternal-fetal relationship.We pose a number of open questions for future research. Although the human fetus remains just out of reach, new technologies portend an era of accelerated discovery of the earliest period of development
Wang, Xiaogang; Durosier, L Daniel; Ross, Michael G; Richardson, Bryan S; Frasch, Martin G
2014-01-01
Severe fetal acidemia during labour can result in life-lasting neurological deficits, but the timely detection of this condition is often not possible. This is because the positive predictive value (PPV) of fetal heart rate (FHR) monitoring, the mainstay of fetal health surveillance during labour, to detect concerning fetal acidemia is around 50%. In fetal sheep model of human labour, we reported that severe fetal acidemia (pH<7.00) during repetitive umbilical cord occlusions (UCOs) is preceded ∼60 minutes by the synchronization of electroencephalogram (EEG) and FHR. However, EEG and FHR are cyclic and noisy, and although the synchronization might be visually evident, it is challenging to detect automatically, a necessary condition for bedside utility. Here we present and validate a novel non-parametric statistical method to detect fetal acidemia during labour by using EEG and FHR. The underlying algorithm handles non-stationary and noisy data by recording number of abnormal episodes in both EEG and FHR. A logistic regression is then deployed to test whether these episodes are significantly related to each other. We then apply the method in a prospective study of human labour using fetal sheep model (n = 20). Our results render a PPV of 68% for detecting impending severe fetal acidemia ∼60 min prior to pH drop to less than 7.00 with 100% negative predictive value. We conclude that this method has a great potential to improve PPV for detection of fetal acidemia when it is implemented at the bedside. We outline directions for further refinement of the algorithm that will be achieved by analyzing larger data sets acquired in prospective human pilot studies.
Studies in Fetal Behavior: Revisited, Renewed, and Reimagined
DiPietro, Janet A.; Costigan, Kathleen A.; Voegtline, Kristin M.
2016-01-01
Among the earliest volumes of this Monograph series was a report by Lester Sontag and colleagues, of the esteemed Fels Institute, on the heart rate of the human fetus as an expression of the developing nervous system. Here, some 75 years later, we commemorate this work and provide historical and contemporary context on knowledge regarding fetal development, as well as results from our own research. These are based on synchronized monitoring of maternal and fetal parameters assessed between 24 and 36 weeks gestation on 740 maternal-fetal pairs compiled from eight separate longitudinal studies, which commenced in the early 1990s. Data include maternal heart rate, respiratory sinus arrhythmia, and electrodermal activity and fetal heart rate, motor activity, and their integration. Hierarchical linear modeling of developmental trajectories reveals that the fetus develops in predictable ways consistent with advancing parasympathetic regulation. Findings also include: within-fetus stability (i.e., preservation of rank ordering over time) for heart rate, motor, and coupling measures; a transitional period of decelerating development near 30 weeks gestation; sex differences in fetal heart rate measures but not in most fetal motor activity measures; modest correspondence in fetal neurodevelopment among siblings as compared to unrelated fetuses; and deviations from normative fetal development in fetuses affected by intrauterine growth restriction and other conditions. Maternal parameters also change during this period of gestation and there is evidence that fetal sex and individual variation in fetal neurobehavior influence maternal physiological processes and the local intrauterine context. Results are discussed within the framework of neuromaturation, the emergence of individual differences, and the bidirectional nature of the maternal-fetal relationship. We pose a number of open questions for future research. Although the human fetus remains just out of reach, new technologies portend an era of accelerated discovery of the earliest period of development. PMID:26303396
Broder, Jacqueline M; Macfadden, Annabell J; Cosens, Lindsay M; Rosenstein, Diana S; Harrison, Tara M
2008-01-01
Closely monitoring snow leopard (Uncia uncia) fetal developments via transabdominal ultrasound, with minimal stress to the animal, was the goal of this project. The staff at Potter Park Zoo has used the principles of habituation, desensitization, and positive reinforcement to train a female snow leopard (U. uncia). Ultrasound examinations were preformed on an unanesthetized feline at 63 and 84 days. The animal remained calm and compliant throughout both procedures. Fetuses were observed and measured on both occasions. The absence of anesthesia eliminated components of psychologic and physiologic stress associated with sedation. This was the first recorded instance of transabdominal ultrasound being carried out on an unanesthetized snow leopard. It documents the feasibility of detecting pregnancy and monitoring fetal development via ultrasound. Zoo Biol 27:78-85, 2008. (c) 2007 Wiley-Liss, Inc.
Anesthesia for myelomeningocele surgery in fetus.
Devoto, Juan Carlos; Alcalde, Juan Luis; Otayza, Felipe; Sepulveda, Waldo
2017-07-01
Administering anesthesia for prenatal repair of myelomeningocele reveals several issues that are unique to this new form of treatment. This includes issues such as fetal well-being, surgical conditions and monitoring, among others. Exploring, analyzing, and understanding the different variables that are involved will help us reduce the high level of risk associated with this surgery. This review provides a systematic approach to the issues that are faced by anesthesiologists during fetal surgery.
Computerized fetal heart rate monitoring after vibroacoustic stimulation in the anencephalic fetus.
Park, Yong-Jin; Park, Seon-Hye; Kim, Young-Jae; Hoh, Jeong-Kyu; Park, Young-Sun; Park, Moon-Il
2010-09-01
To quantify changes in fetal heart rate (FHR) parameters after vibroacoustic stimulation (VAS) and to evaluate the usefulness of VAS testing (VAST) in anencephalic fetuses. Our findings may also help to clarify the route(s) of vibration and sound transmission during VAST. We obtained the antepartum FHR tracings of 16 anencephalic fetuses, including both the nonstress test (NST) and VAST. Using a computerized monitoring system, HYFM, we determined all FHR parameters from data collected for 10 min before and 10 min after VAS, at successive gestational stages. We observed three false reactive responses at term. The false reactive rate for VAST (3/16) was higher than that for NST (1/16). No FHR parameters increased significantly after VAS except for the number of fetal movements (FM), which increased significantly in all gestational groups (25th-32nd and 33rd-40th weeks). These findings call attention to an increased probability of a false reactive response in VAST analysis, when the fetus is affected by a CNS disorder. Increased numbers of FM after VAS suggest that the vibratory pathway is more likely to elicit fetal response than the auditory pathway in this setting, and that the vibratory stimulation travels by subcortical rather than by cortical pathways. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Byaruhanga, R; Bassani, D G; Jagau, A; Muwanguzi, P; Montgomery, A L; Lawn, J E
2015-01-01
Objectives In resource-poor settings, the standard of care to inform labour management is the partograph plus Pinard stethoscope for intermittent fetal heart rate (FHR) monitoring. We compared FHR monitoring in labour using a novel, robust wind-up handheld Doppler with the Pinard as a primary screening tool for abnormal FHR on perinatal outcomes. Design Prospective equally randomised clinical trial. Setting The labour and delivery unit of a teaching hospital in Kampala, Uganda. Participants Of the 2042 eligible antenatal women, 1971 women in active term labour, following uncomplicated pregnancies, were randomised to either the standard of care or not. Intervention Intermittent FHR monitoring using Doppler. Primary outcome measures Incidence of FHR abnormality detection, intrapartum stillbirth and neonatal mortality prior to discharge. Results Age, parity, gestational age, mode of delivery and newborn weight were similar between study groups. In the Doppler group, there was a significantly higher rate of FHR abnormalities detected (incidence rate ratio (IRR)=1.61, 95% CI 1.13 to 2.30). However, in this group, there were also higher though not statistically significant rates of intrapartum stillbirths (IRR=3.94, 0.44 to 35.24) and neonatal deaths (IRR=1.38, 0.44 to 4.34). Conclusions Routine monitoring with a handheld Doppler increased the identification of FHR abnormalities in labour; however, our trial did not find evidence that this leads to a decrease in the incidence of intrapartum stillbirth or neonatal death. Trial registration number Clinical Trails.gov (1000031587). PMID:25636792
Byaruhanga, R; Bassani, D G; Jagau, A; Muwanguzi, P; Montgomery, A L; Lawn, J E
2015-01-30
In resource-poor settings, the standard of care to inform labour management is the partograph plus Pinard stethoscope for intermittent fetal heart rate (FHR) monitoring. We compared FHR monitoring in labour using a novel, robust wind-up handheld Doppler with the Pinard as a primary screening tool for abnormal FHR on perinatal outcomes. Prospective equally randomised clinical trial. The labour and delivery unit of a teaching hospital in Kampala, Uganda. Of the 2042 eligible antenatal women, 1971 women in active term labour, following uncomplicated pregnancies, were randomised to either the standard of care or not. Intermittent FHR monitoring using Doppler. Incidence of FHR abnormality detection, intrapartum stillbirth and neonatal mortality prior to discharge. Age, parity, gestational age, mode of delivery and newborn weight were similar between study groups. In the Doppler group, there was a significantly higher rate of FHR abnormalities detected (incidence rate ratio (IRR)=1.61, 95% CI 1.13 to 2.30). However, in this group, there were also higher though not statistically significant rates of intrapartum stillbirths (IRR=3.94, 0.44 to 35.24) and neonatal deaths (IRR=1.38, 0.44 to 4.34). Routine monitoring with a handheld Doppler increased the identification of FHR abnormalities in labour; however, our trial did not find evidence that this leads to a decrease in the incidence of intrapartum stillbirth or neonatal death. Clinical Trails.gov (1000031587). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Sholapurkar, S L
2010-01-01
Intermittent auscultation of fetal heart rate is an accepted practice in low risk labours in many countries. National guidelines on intrapartum fetal monitoring were critically reviewed regarding timing and frequency of intermittent auscultation. Hypothetical but plausible examples are presented to illustrate that it may be possible to miss significant fetal distress with strict adherence to current guidelines. Opinion is forwarded that intermittent auscultation should be performed for 60 seconds before and after three contractions over about 10 min every half an hour in the first stage of labour. Reasons are put forward to show how this could be more practical and patient friendly and at the same time could improve detection of fetal distress. The current recommendation of intermittent auscultation every 15 min in the first stage is associated with poor compliance and leads to unnecessary burden, stress and medicolegal liability for birth attendants. Modification of current national guidelines would be desirable.
A phantom with pulsating artificial vessels for non-invasive fetal pulse oximetry.
Laqua, Daniel; Pollnow, Stefan; Fischer, Jan; Ley, Sebastian; Husar, Peter
2014-01-01
Arterial oxygen saturation of the fetus is an important parameter for monitoring its physical condition. During labor and delivery the transabdominal non-invasive fetal pulse oximetry could minimize the risk for mother and fetus, compared to other existing invasive examination methods. In this contribution, we developed a physical-like phantom to investigate new sensor circuits and algorithms of a non-invasive diagnostic method for fetal pulse oximetry. Hence, the developed artificial vascular system consists of two independent tube systems representing the maternal and fetal vessel system. The arterial blood pressure is reproduced with a pre-pressure and an artificial vascular system. Each pulse wave can be reproduced, by digital control of a proportional valve, adjustable viscoelastic elements, and resistances. The measurements are performed by pressure transducers, optical sensor units, and a coplanar capacitive sensor. Transmission and reflection measurements have shown that the fetal and maternal pulse waves can be reproduced qualitatively. The measured light represents the transabdominal modulated signal on an abdomen of a pregnant woman.
Fetal growth in muskoxen determined by transabdominal ultrasonography.
Pharr, J W; Rowell, J E; Flood, P F
1994-01-01
A 5 MHz commercial sector scanner was used to monitor 13 muskox pregnancies and establish normal fetal growth curves. Examinations were carried out between 40 and 197 days of gestation and pregnancy could be detected throughout the period. Early pregnancies were found by scanning lateral to the udder but as pregnancy progressed the fetus was found closer to the dam's umbilicus. Measurements of cranial and abdominal diameters taken at about two week intervals in seven uncomplicated pregnancies in four cows were used to construct fetal growth curves. These can be reliably used in the reproductive management of muskoxen. In addition a series of regressions based on measurements of the fetuses of muskoxen killed in the Arctic are provided. These allow cranial and abdominal diameters to be related to fetal weight and crown-rump length. Images Fig. 1. Fig. 2. PMID:7954117
Horowitz, David P; Wang, Tony J C; Wuu, Cheng-Shie; Feng, Wenzheng; Drassinower, Daphnie; Lasala, Anita; Pieniazek, Radoslaw; Cheng, Simon; Connolly, Eileen P; Lassman, Andrew B
2014-11-01
We examined the fetal dose from irradiation of glioblastoma during pregnancy using intensity modulated radiation therapy (IMRT), and describe fetal dose minimization using mobile shielding devices. A case report is described of a pregnant woman with glioblastoma who was treated during the third trimester of gestation with 60 Gy of radiation delivered via a 6 MV photon IMRT plan. Fetal dose without shielding was estimated using an anthropomorphic phantom with ion chamber and diode measurements. Clinical fetal dose with shielding was determined with optically stimulated luminescent dosimeters and ion chamber. Clinical target volume (CTV) and planning target volume (PTV) coverage was 100 and 98 % receiving 95 % of the prescription dose, respectively. Normal tissue tolerances were kept below quantitative analysis of normal tissue effects in the clinic (QUANTEC) recommendations. Without shielding, anthropomorphic phantom measurements showed a cumulative fetal dose of 0.024 Gy. In vivo measurements with shielding in place demonstrated a cumulative fetal dose of 0.016 Gy. The fetal dose estimated without shielding was 0.04 % and with shielding was 0.026 % of the target dose. In vivo estimation of dose equivalent received by the fetus was 24.21 mSv. Using modern techniques, brain irradiation can be delivered to pregnant patients in the third trimester with very low measured doses to the fetus, without compromising target coverage or normal tissue dose constraints. Fetal dose can further be reduced with the use of shielding devices, in keeping with the principle of as low as reasonably achievable.
The ovine fetal endocrine reflex responses to haemorrhage are not mediated by cardiac nerves
Wood, Charles E
2002-01-01
This study was designed to test the hypothesis that cardiac receptors tonically inhibit the secretion of renin, arginine vasopressin (AVP) and adrenocorticotropic hormone (ACTH) in late-gestation fetal sheep. Eight chronically catheterised fetal sheep between 122 and 134 days gestation were subjected to injection or infusion of saline or 4 % procaine into the pericardial space. Fetal blood pressure and heart rate were monitored and fetal blood samples were drawn to measure the response to these injections. Injection of procaine into the pericardial space effectively blocked cardiac nerves, as evidenced by a reduction in the variability of fetal heart rate and by the blockade of reflex reductions in fetal heart rate after intravenous injection of phenylephrine (an α-adrenergic agonist which raises blood pressure). Injection of saline had no discernable effects on any of the measured variables. A single injection of procaine, followed by a slow infusion, produced a transient blockade of cardiac nerves. Multiple injections of procaine produced a sustained blockade of cardiac nerves and a sustained rise in fetal plasma renin activity and ACTH. In none of the experiments did procaine significantly alter fetal plasma AVP concentrations. In 11 fetuses between 121 and 134 days gestation, we combined the cardiac nerve blockade with slow haemorrhage to test the cardiac nerves as mediators of the endocrine response to haemorrhage in utero. Cardiac nerve blockade exaggerated the fetal blood gas response to haemorrhage somewhat but did not significantly alter the magnitude of the ACTH, AVP, or plasma renin activity response to haemorrhage. We conclude that cardiac nerves in the late-gestation fetal sheep have minor influences on plasma renin activity and ACTH in normovolaemic fetuses, but that changes in cardiac nerve activity do not mediate the endocrine responsiveness to haemorrhage. PMID:12042365
Noninvasive monitoring of fetal growth and development in the Siberian polecat (Mustela eversmanni)
Wimsatt, Jeffrey; Johnson, Jay D.; Wrigley, Robert H.; Biggins, Dean E.; Godbey, Jerry L.
1998-01-01
The Siberian polecat (Mustela eversmanni) is the preferred species to assess procedures and establish normative values for application in the related and endangered black-footed ferret (Mustela nigripes). This study was undertaken to physically, ultrasonographically, and radiographically evaluate fetal development in a spontaneously breeding captive Siberian polecat population. Ultrasonographically, fetal sac enlargement allowed presumptive preg nancy detection as early as 12 days of gestation, the fetal pole was the first definitive sign of pregnancy at about 18 days of gestation, when the fetal heart beat also appeared, and definitive pregnancy detection by ultrasound was essentially 100% accurate after 18 days. The estimation of fetal number by ultrasound was less reliable than by radiography, as it is in other litter-bearing species. Crown-rump growth, organ differentiation, and calcification patterns resembled those of domestic carnivores except that comparable developmental stages in polecats occurred at dispro portionately later times, suggesting that young Siberian polecats are delivered in a less developed state. Careful palpation permitted detection of pregnancy after day 17 but with less certainty than with ultrasound. Radiographic evaluation was insensitive and of limited value for pregnancy detection until near term. Litter number and fetal detail were difficult to assess until ossification could be observed, 3-6 days before parturition.
Noninvasive monitoring of fetal growth and development in the Siberian polecat (Mustela eversmanni).
Wimsatt, J; Johnson, J D; Wrigley, R H; Biggins, D E; Godbey, J L
1998-12-01
The Siberian polecat (Mustela eversmanni) is the preferred species to assess procedures and establish normative values for application in the related and endangered black-footed ferret (Mustela nigripes). This study was undertaken to physically, ultrasonographically, and radiographically evaluate fetal development in a spontaneously breeding captive Siberian polecat population. Ultrasonographically, fetal sac enlargement allowed presumptive pregnancy detection as early as 12 days of gestation, the fetal pole was the first definitive sign of pregnancy at about 18 days of gestation, when the fetal heart beat also appeared, and definitive pregnancy detection by ultrasound was essentially 100% accurate after 18 days. The estimation of fetal number by ultrasound was less reliable than by radiography, as it is in other litter-bearing species. Crown-rump growth, organ differentiation, and calcification patterns resembled those of domestic carnivores except that comparable developmental stages in polecats occurred at disproportionately later times, suggesting that young Siberian polecats are delivered in a less developed state. Careful palpation permitted detection of pregnancy after day 17 but with less certainty than with ultrasound. Radiographic evaluation was insensitive and of limited value for pregnancy detection until near term. Litter number and fetal detail were difficult to assess until ossification could be observed, 3-6 days before parturition.
Künzel, Wolfgang; Misselwitz, Björn
2003-09-22
To investigate the causes of ante partum fetal death (APFD) and to evaluate the diagnostic methods for prevention. A population-based retrospective study was conducted in 293091 deliveries from 1996 to 2000 in the State of Hesse, Germany. The investigations focus on mortality of infants during pregnancy, separated between singletons of 37-42 weeks (n=361) and 23-36 weeks (n=550), and multiple births (n=76). In 44 cases, the gestational age was unknown and in 19 cases lower than 23 weeks or greater than 43 weeks. In total 1006 cases remained and were subject for evaluation. Perinatal mortality (PM) was 0.56%. APFD occurred in 1050 cases (0.3%), i.e. 63.5% of PM. Risk factors from the medical history during pregnancy could be identified in 515 cases (51.2%). Significant risk factors were social burden (odds ratio (OR) 58.3), diabetes mellitus (OR 5.4) and gestational diabetes (OR 2.1), psychological burden (OR 4.8), proteinuria (OR 2.8), maternal age (OR 1.7) and maternal smoking, depending on the number of cigarettes. The risk factors show a difference in significance, if related to the gestational age and multiple pregnancies. The contribution of malformations to APFD was 7.8%. There was however a number of unexpected fetal deaths with unidentified risk factors: n=415 (41.3%). In this group, fetal growth restriction was observed in 38.1%. Compared to control, APFD was three to five times higher in fetal growth retardation below the 10th percentile. Fetal death was closely related to fetal surveillance, i.e. the number of antenatal visits, ultrasound measurements, and fetal heart rate monitoring. Fetal ante partum fetal death can be reduced at least by 50%, if the available methods for fetal surveillance are employed aiming to detect indications of fetal oxygen deprivation at an early stage.
Frasch, Martin G; Baier, Carlos J; Antonelli, Marta C; Metz, Gerlinde A S
2018-01-01
Prenatal stress (PS) impacts early behavioral, neuroimmune, and cognitive development. Pregnant rat models have been very valuable in examining the mechanisms of such fetal programming. A newer pregnant sheep model of maternal stress offers the unique advantages of chronic in utero monitoring and manipulation. This chapter presents the techniques used to model single and multigenerational stress exposures and their pleiotropic effects on the offspring.
Eden, Robert D; Evans, Mark I; Evans, Shara M; Schifrin, Barry S
2018-04-01
The near-ubiquitous use of electronic fetal monitoring has failed to lower the rates of both cerebral palsy and emergency operative deliveries (EODs). Its performance metrics have low sensitivity, specificity, and predictive values for both. There are many EODs, but the vast majority have normal outcomes. The EODs, however, cause serious disruption in the delivery suite routine with increased complications, anxiety, and concern for all. We developed the fetal reserve index (FRI) as multicomponent algorithm including 4 FHR components (analyzed individually), uterine activity, and maternal, obstetrical, and fetal risk factors to assess risk of cerebral palsy and EOD. Scores were categorized into green, yellow, and red zones. Here, we studied 300 patients by the FRI, all of whom had normal neonatal outcomes. We attempted to distinguish the clinical course of those cases which required an EOD versus controls which did not. 51 cases with EOD had FRIs much lower than 249 non-EOD cases. The red zone was reached more frequently ( P < .001) and lasted longer (1.06 vs 0.05 hours; P < .001). Reaching the red zone had a sensitivity of 92% for EOD, with a positive predictive value of 64% and a false positive rate of 10.4%. Our data suggest the FRI can significantly lower the incidence of EODs by identifying the opportunity for intrauterine resuscitation. Our approach can reduce the disruptive effects of EODs and their concomitant increased risks of complications. The FRI may provide a metric that can refine labor management to reduce CP and EODs.
Zhao, S; Ai, L; Zhang, H
2000-01-01
To discuss the significance of amnioinfusion and amniotic fluid exchange under continuous internal fetal heart rate (FHR) monitoring for management of fetal distress during labor. 136 cases with frequent variable deceleration (VD) and meconium stained amniotic fluid during labor were divided into two groups: the study group (68 cases) and the control group (68 cases). The former were treated by amnioinfusion and amniotic fluid exchange, while oxygen inhalation, change of body position, and intravenous infusion for the control group. In the study group, VD disappeared or relieved in 62 cases obviously, and the efficacy rate reached 91.2% (62/68). 48 cases with II degree meconium stained amniotic fluid were treated by amniotic fluid exchange, amniotic fluid became clear or turned to I degree stained in 39 cases. In the control group, VD relieved in 20 cases, the efficacy rate was 19.4%, significantly lower than that of the study group (P < 0.01). In the study group, cesarean section rate was 14.7% neonatal asphyxia 7.4% while they were 47.1% and 48.5% in the control group respectively (P < 0.01; P < 0.01). Neonatal pneumonia caused by meconium aspiration occurred in 13 cases, meconium aspiration syndrome (MAS) 8 cases, with 5 newborns died in the control group, while there was no neonatal death in the study group. There was no significant difference on puerperal morbidity between the 2 groups (P > 0.05). Amnioinfusion and AF exchange during labor are one of the effective treatment methods for fetal distress and prevention for MAS.
Fetal phonocardiography--past and future possibilities.
Kovács, Ferenc; Horváth, Csaba; Balogh, Adám T; Hosszú, Gábor
2011-10-01
The paper presents an overview of the 15 year long development of fetal phonocardiography including the works on the applied signal processing methods for identification of sound components. Based on the improvements achieved on this field, the paper shows that beyond the traditional CTG test the phonocardiography may be successfully applied for long-term fetal measurements and home monitoring. In addition, by indication of heart murmurs based on a comprehensive analysis of the recorded heart sound congenital heart defects can also be detected together with additional features in the third trimester. This makes an early widespread screening possible combined with the prescribed CTG test even at home using a telemedicine system. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
[Guaranteeing fetal well-being in water childbirth: is it possible?].
Dodero, D; Caporale, E; Cardamone, C; Corticelli, A; Messuti, G; Francescangeli, U; Sirito, R
2000-01-01
The criteria, which a modern obstetric department is based on, are to deliver serenely and naturally according to the mother's personal exigencies and preserving the child's right to his/her own safety. The attempt to offer the woman a natural place with respect for these principles has improved the knowledge about the physiologic changes of the female organism during labour and water birth. Our experience about water birth began on 1st of July 2000, the day of the inauguration of the new birth room of the maternal-infantile department of the hospital of Lavagna. We nursed 15 women during labour and water birth, 11 were multiparas, 4 were primiparas, the average age was 31-year-old. We used the existing criteria of maternal and fetal selection for the care of physiologic water birth with a low risk. Particularly, the fetal heart rate was monitored at least for 30 minutes before the immersion into water and then at scheduled intervals during labour. To this purpose we used a cardiotocograph provided with an ultrasound probe (with high density of crystals) and with a toco (with high sensitivity), both waterproof and wireless. In our sample the episiotomy was not performed and 3rd degree lacerations did not happen. The neonatal average weight was 3100 gr for the primiparas and 3040 gr for the multiparas, respectively. The Apgar measurement was never lower than 8. The average time of labour was 6 hours for the group of the primiparas and 4.25 hours for the multiparas, respectively. In conclusion the monitoring of fetal welfare during water labour does not substantially differ from the monitoring of traditional labour, but it requires specific equipments.
Kc, Ashish; Wrammert, Johan; Clark, Robert B; Ewald, Uwe; Målqvist, Mats
2016-08-19
Newborns are at the greatest risk for dying during the intrapartum period, including labor and delivery, and the first day of life. Fetal heart rate monitoring (FHRM) and partogram use to track labor progress are evidence-based techniques that can help to identify maternal and fetal risk factors so that these can be addressed early. The objective of this study was to assess health worker adherence to protocols for FHRM and partogram use during the intrapartum period, and to assess the association between adherence and intrapartum stillbirth in a tertiary hospital of Nepal. A case-referent study was conducted over a 15-month period. Cases included all intrapartum stillbirths, while 20 % of women with live births were randomly selected on admission to make up the referent population. The frequency of FHRM and the use of partogram were measured and their association to intrapartum stillbirth was assessed using logistic regression analysis. During the study period, 4,476 women with live births were enrolled as referents and 136 with intrapartum stillbirths as cases. FHRM every 30 min was only completed in one-fourth of the deliveries, and labor progress was monitored using a partogram in just over half. With decreasing frequency of FHRM, there was an increased risk of intrapartum stillbirth; FHRM at intervals of more than 30 min resulted in a four-fold risk increase for intrapartum stillbirth (aOR 4.17, 95 % CI 2.0-8.7), and the likelihood of intrapartum stillbirth increased seven times if FHRM was performed less than every hour or not at all (aOR 7.38, 95 % CI 3.5-15.4). Additionally, there was a three-fold increased risk of intrapartum stillbirth if the partogram was not used (aOR 3.31, 95 % CI 2.0-5.4). The adherence to FHRM and partogram use was inadequate for monitoring intrapartum progress in a tertiary hospital of Nepal. There was an increased risk of intrapartum stillbirth when fetal heart rate was inadequately monitored and when the progress of labor was not monitored using a partogram. Further exploration is required in order to determine and understand the barriers to adherence; and further, to develop tools, techniques and interventions to prevent intrapartum stillbirth. ISRCTN97846009 .
[Fetal version as ambulatory intervention].
Nohe, G; Hartmann, W; Klapproth, C E
1996-06-01
The external cephalic version (ECV) of the fetus at term reduces the maternal and fetal risks of intrapartum breech presentation and Caesarean delivery. Since 1986 over 800 external cephalic versions were performed in the outpatient Department of Obstetrics and Gynaecology of the Städtische Frauenklinik Stuttgart. 60.5% were successful. NO severe complications occurred. Sufficient amniotic fluid as well as the mobility of the fetal breech is a major criterion for the success of the ECV. Management requires a safe technique for mother and fetus. This includes ultrasonography, elektronic fetal monitoring and the ability to perform immediate caesarean delivery as well as the performance of ECV without analgesicas and sedatives. More than 70% of the ECV were successful without tocolysis. In unsuccessful cases the additional use of tocolysis improves the success rate only slightly. Therefore routine use of tocolysis does not appear necessary. External cephalic version can be recommended as an outpatient treatment without tocolysis.
Merialdi, Mario; Widmer, Mariana; Gülmezoglu, Ahmet Metin; Abdel-Aleem, Hany; Bega, George; Benachi, Alexandra; Carroli, Guillermo; Cecatti, Jose Guilherme; Diemert, Anke; Gonzalez, Rogelio; Hecher, Kurt; Jensen, Lisa N; Johnsen, Synnøve L; Kiserud, Torvid; Kriplani, Alka; Lumbiganon, Pisake; Tabor, Ann; Talegawkar, Sameera A; Tshefu, Antoinette; Wojdyla, Daniel; Platt, Lawrence
2014-05-02
In 2006 WHO presented the infant and child growth charts suggested for universal application. However, major determinants for perinatal outcomes and postnatal growth are laid down during antenatal development. Accordingly, monitoring fetal growth in utero by ultrasonography is important both for clinical and scientific reasons. The currently used fetal growth references are derived mainly from North American and European population and may be inappropriate for international use, given possible variances in the growth rates of fetuses from different ethnic population groups. WHO has, therefore, made it a high priority to establish charts of optimal fetal growth that can be recommended worldwide. This is a multi-national study for the development of fetal growth standards for international application by assessing fetal growth in populations of different ethnic and geographic backgrounds. The study will select pregnant women of high-middle socioeconomic status with no obvious environmental constraints on growth (adequate nutritional status, non-smoking), and normal pregnancy history with no complications likely to affect fetal growth. The study will be conducted in centres from ten developing and industrialized countries: Argentina, Brazil, Democratic Republic of Congo, Denmark, Egypt, France, Germany, India, Norway, and Thailand. At each centre, 140 pregnant women will be recruited between 8 + 0 and 12 + 6 weeks of gestation. Subsequently, visits for fetal biometry will be scheduled at 14, 18, 24, 28, 32, 36, and 40 weeks (+/- 1 week) to be performed by trained ultrasonographers.The main outcome of the proposed study will be the development of fetal growth standards (either global or population specific) for international applications. The data from this study will be incorporated into obstetric practice and national health policies at country level in coordination with the activities presently conducted by WHO to implement the use of the Child Growth Standards.
A half century of electronic fetal monitoring and bioethics: silence speaks louder than words.
Sartwelle, Thomas P; Johnston, James C; Arda, Berna
2017-01-01
Bioethics abolished the prevailing Hippocratic tenet instructing physicians to make treatment decisions, replacing it with autonomy through informed consent. Informed consent allows the patient to choose treatment after options are explained by the physician. The appearance of bioethics in 1970 coincided with the introduction of electronic fetal monitoring (EFM), which evolved to become the fetal surveillance modality of choice for virtually all women in labor. Autonomy rapidly pervaded all medical procedures, but there was a clear exemption for EFM. Even today, EFM remains immune to the doctrine of informed consent despite continually mounting evidence which proves the procedure is nothing more than myth, illusion and junk science that subjects mothers and babies alike to increased risks of morbidity and mortality. And ethicists have remained utterly silent through a half century of EFM misuse. Our article explores this egregious ethical failure by reviewing EFM's lack of clinical efficacy, discussing the EFM related harm to mothers and babies, and focusing on the reasons that this obstetrical procedure eluded the revolutionary change from the Hippocratic tradition to autonomy through informed consent.
Hoerst, B J; Fairman, J
2000-06-01
Electronic fetal monitoring (EFM) is one example of a biomedical technology that rapidly diffused from an experimental innovation into a standard medical practice. First developed in the 1950s, EFM became commercially available in the early 1970s and quickly transformed intrapartum obstetrical practice. Assessments and interventions, which practitioners had previously based primarily on laboring women's subjective reports of bodily sensations, were now being based on quantifiable objective data from uterine activity and fetal heart rate transducers. Despite concerns of over-medicalization of the natural event of birth, iatrogenesis related to the increased incidence of operative deliveries, and escalating costs, EFM became widely accepted as routine and necessary by both practitioners and patients. By presenting the confident expectations and cautious reservations of various practitioners and patients to EFM, this article explores the rapid diffusion of EFM within the social context of the 1970s. A special focus is given to the perspective of intrapartum obstetrical nurses, because they have been the primary users of this perinatal technology since its introduction.
Diffuse optical tomography and spectroscopy of breast cancer and fetal brain
NASA Astrophysics Data System (ADS)
Choe, Regine
Diffuse optical techniques utilize light in the near infrared spectral range to measure tissue physiology non-invasively. Based on these measurements, either on average or a three-dimensional spatial map of tissue properties such as total hemoglobin concentration, blood oxygen saturation and scattering can be obtained using model-based reconstruction algorithms. In this thesis, diffuse optical techniques were applied for in vivo breast cancer imaging and trans-abdominal fetal brain oxygenation monitoring. For in vivo breast cancer imaging, clinical diffuse optical tomography and related instrumentation was developed and used in several contexts. Bulk physiological properties were quantified for fifty-two healthy subjects in the parallel-plate transmission geometry. Three-dimensional images of breast were reconstructed for subjects with breast tumors and, tumor contrast with respect to normal tissue was found in total hemoglobin concentration and scattering and was quantified for twenty-two breast carcinomas. Tumor contrast and tumor volume changes during neoadjuvant chemotherapy were tracked for one subject and compared to the dynamic contrast-enhanced MRI. Finally, the feasibility for measuring blood flow of breast tumors using optical methods was demonstrated for seven subjects. In a qualitatively different set of experiments, the feasibility for trans-abdominal fetal brain oxygenation monitoring was demonstrated on pregnant ewes with induced fetal hypoxia. Preliminary clinical experiences were discussed to identify future directions. In total, this research has translated diffuse optical tomography techniques into clinical research environment.
Fetal Mouse Cardiovascular Imaging Using a High-frequency Ultrasound (30/45MHZ) System.
Touma, Marlin
2018-05-05
Congenital heart defects (CHDs) are the most common cause of childhood morbidity and early mortality. Prenatal detection of the underlying molecular mechanisms of CHDs is crucial for inventing new preventive and therapeutic strategies. Mutant mouse models are powerful tools to discover new mechanisms and environmental stress modifiers that drive cardiac development and their potential alteration in CHDs. However, efforts to establish the causality of these putative contributors have been limited to histological and molecular studies in non-survival animal experiments, in which monitoring the key physiological and hemodynamic parameters is often absent. Live imaging technology has become an essential tool to establish the etiology of CHDs. In particular, ultrasound imaging can be used prenatally without surgically exposing the fetuses, allowing maintaining their baseline physiology while monitoring the impact of environmental stress on the hemodynamic and structural aspects of cardiac chamber development. Herein, we use the High-Frequency Ultrasound (30/45) system to examine the cardiovascular system in fetal mice at E18.5 in utero at the baseline and in response to prenatal hypoxia exposure. We demonstrate the feasibility of the system to measure cardiac chamber size, morphology, ventricular function, fetal heart rate, and umbilical artery flow indices, and their alterations in fetal mice exposed to systemic chronic hypoxia in utero in real time.
Neldam, S; Osler, M; Hansen, P K; Nim, J; Smith, S F; Hertel, J
1986-10-01
In a prospective clinical randomized investigation 487 women had the condition of the fetus during labour supervised by means of stethoscope (AUS), while 482 women went through labour under surveillance of electronic fetal monitoring, cardiotocography (EFM). 349 women refused to participate in the investigation (NAI) and had delivery conducted according to the normal procedures of the department (70% AUS, 30% EFM). Significantly more pathological fetal heart rate patterns (FHR) were found in the EFM group compared to the AUS group in both the first and the second stage of labour. As a result significantly more vacuum extractions were performed in the EFM group than in the AUS group, while no statistical difference was found between the groups in the incidence of acute cesarean sections carried out for asphyxia. One case of intrapartum death occurred in the AUS group. No differences were found in Apgar scores after 1 and 5 min or in neonatal morbidity at examination on the 2nd and 5th days after delivery. A tendency towards more biochemically compromised children was found in the AUS group. The specificity for both methods was found to be acceptably high (80%), while the predictive value for both methods was low (50%). More research is therefore urgently needed to evaluate supplementary investigations and parameters for the evaluation of the intrapartum fetal condition.
Application of higher-order cepstral techniques in problems of fetal heart signal extraction
NASA Astrophysics Data System (ADS)
Sabry-Rizk, Madiha; Zgallai, Walid; Hardiman, P.; O'Riordan, J.
1996-10-01
Recently, cepstral analysis based on second order statistics and homomorphic filtering techniques have been used in the adaptive decomposition of overlapping, or otherwise, and noise contaminated ECG complexes of mothers and fetals obtained by a transabdominal surface electrodes connected to a monitoring instrument, an interface card, and a PC. Differential time delays of fetal heart beats measured from a reference point located on the mother complex after transformation to cepstra domains are first obtained and this is followed by fetal heart rate variability computations. Homomorphic filtering in the complex cepstral domain and the subuent transformation to the time domain results in fetal complex recovery. However, three problems have been identified with second-order based cepstral techniques that needed rectification in this paper. These are (1) errors resulting from the phase unwrapping algorithms and leading to fetal complex perturbation, (2) the unavoidable conversion of noise statistics from Gaussianess to non-Gaussianess due to the highly non-linear nature of homomorphic transform does warrant stringent noise cancellation routines, (3) due to the aforementioned problems in (1) and (2), it is difficult to adaptively optimize windows to include all individual fetal complexes in the time domain based on amplitude thresholding routines in the complex cepstral domain (i.e. the task of `zooming' in on weak fetal complexes requires more processing time). The use of third-order based high resolution differential cepstrum technique results in recovery of the delay of the order of 120 milliseconds.
Newnham, J P; Phillips, J M; Stock, R
1992-11-16
To report the first four years' clinical experience with fetal intravascular blood transfusion for the treatment of fetal haemolytic anaemia in Western Australia. King Edward Memorial Hospital, Perth, which is the sole tertiary level perinatal centre in Western Australia with a referral base of approximately 25,000 pregnancies each year. Transfusion was by injection of packed cells from Rh-negative donors into the fetal umbilical vein near the site of insertion into the placenta. Fetal haemoglobin levels were measured before and after each transfusion. In most cases, the fetus was paralysed by intramuscular tubocurarine. Sixty intravenous transfusions were performed in 20 pregnancies. At the time of the initial transfusion, the mean haemoglobin level was 5.8 g/dL (range, 2.5-8.5 g/dL) and six fetuses had signs of hydrops. The case survival rate was 80% and the procedure survival rate was 93%. Three of the deaths occurred in the first five cases. Caesarean section was performed during two of the procedures, one because of bleeding from the cord puncture site and one because of tamponade of the umbilical vessels. Fetal intravascular transfusion is a highly effective treatment for fetal alloimmunisation and allows pregnancies to continue to term and to be delivered vaginally. However, the procedure may be difficult and requires a team approach with ready access to fetal monitoring and emergency caesarean section. Our results suggest that increasing experience of the team is a major factor in improved outcome.
Patey, Andrea M; Curran, Janet A; Sprague, Ann E; Francis, Jill J; Driedger, S Michelle; Légaré, France; Lemyre, Louise; Pomey, Marie-Pascale A; Grimshaw, Jeremy M
2017-09-25
Intermittent Auscultation (IA) is the recommended method of fetal surveillance for healthy women in labour. However, the majority of women receive continuous electronic monitoring. We used the Theoretical Domains Framework (TDF) to explore the views of Birthing Unit nurses about using IA as their primary method of fetal surveillance for healthy women in labour. Using a semi-structured interview guide, we interviewed a convenience sample of birthing unit nurses throughout Ontario, Canada to elicit their views about fetal surveillance. Interviews were recorded and transcribed verbatim. Transcripts were content analysed using the TDF and themes were framed as belief statements. Domains potentially key to changing fetal surveillance behaviour and informing intervention design were identified by noting the frequencies of beliefs, content, and their reported influence on the use of IA. We interviewed 12 birthing unit nurses. Seven of the 12 TDF domains were perceived to be key to changing birthing unit nurses' behaviour The nurses reported that competing tasks, time constraints and the necessity to multitask often limit their ability to perform IA (domains Beliefs about capabilities; Environmental context and resources). Some nurses noted the decision to use IA was something that they consciously thought about with every patient while others stated it their default decision as long as there were no risk factors (Memory, attention and decision processes, Nature of behaviour). They identified positive consequences (e.g. avoid unnecessary interventions, mother-centered care) and negative consequences of using IA (e.g. legal concerns) and reported that the negative consequences can often outweigh positive consequences (Beliefs about consequences). Some reported that hospital policies and varying support from care teams inhibited their use of IA (Social influences), and that support from the entire team and hospital management would likely increase their use (Social influences; Behavioural regulation). We identified potential influences on birthing unit nurses' use of IA as their primary method of fetal surveillance. These beliefs suggest potential targets for behaviour change interventions to promote IA use.
A simplified form of cardiotocography for antenatal fetal assessment.
Mahomed, K; Gupta, B K; Matikiti, L; Murape, T S
1992-12-01
Antenatal cardiotocography has become the primary method of evaluation of fetal wellbeing, and the relationship between the presence of fetal heart rate accelerations in response to fetal movement and subsequent good fetal outcome has been demonstrated. However, in areas where electronic monitors are few or not available it would be useful if such accelerations could be demonstrated using the Pinard stethoscope. A prospective study involving 200 women with a singleton pregnancy of more than 34 weeks gestation was performed at Harare Maternity Hospital, Harare, Zimbabwe, when a 6 min electronic trace using an external transducer was compared with simultaneously performed 6 min manual record using the Pinard stethoscope. The findings showed that the manual record has a sensitivity of 75% and although traces with excessive base line variability would show an acceleration on the manual record, in no case with a flat trace was an acceleration noted on the manual record. This acceptable degree of sensitivity would allow for a significant decrease in the number of women being referred for electronic tracing and would be a more appropriate use of limited resources in terms of manpower and equipment.
Soncini, Emanuele; Paganelli, Simone; Vezzani, Cristina; Gargano, Giancarlo; Giovanni Battista, La Sala
2014-09-01
To assess the ability of the intrapartum fetal heart rate interpretation system developed in 2008 by the National Institute of Child Health and Human Development (NICHD) to predict fetal metabolic acidosis at delivery and neonatal neurological morbidity. We analyzed the intrapartum fetal heart rate tracings of 314 singleton fetuses at ≥ 37 weeks using the NICHD three-tier system of interpretation: Category I (normal), Category II (indeterminate) and Category III (abnormal). Category II was further divided into Category IIA, with moderate fetal heart rate variability or accelerations, and Category IIB, with minimal/absent fetal heart rate variability and no accelerations. The presence and duration of the different patterns were compared with several clinical neonatal outcomes and with umbilical artery acid-base balance at birth. The mean values of pH and base excess decreased proportionally as tracings worsened (p < 0.001). The duration of at least 30 min for Category III tracings was highly predictive of a pH <7.00 and a base excess ≤-12 mmol/L. The same was true for the duration of Category IIB tracings that lasted for at least 50 min. Our study demonstrates that the interpretation of fetal heart rate tracings based on a strictly standardized system is closely associated with umbilical artery acid-base status at delivery.
Bracken, M B; Belanger, K; Hellenbrand, K; Dlugosz, L; Holford, T R; McSharry, J E; Addesso, K; Leaderer, B
1995-05-01
Several animal and human studies indicate that fetal growth may be retarded following exposure to electromagnetic fields (EMF). We conducted a prospective study (N = 2,967) to evaluate the relation of birthweight and fetal growth retardation with use of electrically heated beds (electric blankets and heated water beds) during pregnancy. A "nested" study design allowed monitoring of exposure at different stages of pregnancy using both direct and indirect methods. We assessed EMF exposure using personal monitors, home measurement, video display terminal use, and wire code. Exposure to EMF during pregnancy, either at conception, at < or = 16 weeks, or in the third trimester, showed no important relation to risk of low birth-weight or fetal growth retardation. This result was the same whether we used subjective measures of exposure or direct measurement. Use of video display terminals at home or work, exposure to > or = 2.0-milligauss fields as measured by home or personal monitors, and home wire code were unrelated to the reproductive outcomes studied. A time-weighted analysis of electric bed use, which accounted for strength of EMF exposure and hours of use, also showed evidence of no meaningful increase in risk. None of the exposure measures showed a dose response relation to risk. We conclude that risk of low birth-weight and intrauterine growth retardation is not increased after electrically heated bed use during pregnancy.
Prenatal air pollution exposure and ultrasound measures of fetal growth in Los Angeles, California.
Ritz, Beate; Qiu, Jiaheng; Lee, Pei-Chen; Lurmann, Fred; Penfold, Bryan; Erin Weiss, Robert; McConnell, Rob; Arora, Chander; Hobel, Calvin; Wilhelm, Michelle
2014-04-01
Few previous studies examined the impact of prenatal air pollution exposures on fetal development based on ultrasound measures during pregnancy. In a prospective birth cohort of more than 500 women followed during 1993-1996 in Los Angeles, California, we examined how air pollution impacts fetal growth during pregnancy. Exposure to traffic related air pollution was estimated using CALINE4 air dispersion modeling for nitrogen oxides (NOx) and a land use regression (LUR) model for nitrogen monoxide (NO), nitrogen dioxide (NO2) and NOx. Exposures to carbon monoxide (CO), NO2, ozone (O3) and particles <10μm in aerodynamic diameter (PM10) were estimated using government monitoring data. We employed a linear mixed effects model to estimate changes in fetal size at approximately 19, 29 and 37 weeks gestation based on ultrasound. Exposure to traffic-derived air pollution during 29 to 37 weeks was negatively associated with biparietal diameter at 37 weeks gestation. For each interquartile range (IQR) increase in LUR-based estimates of NO, NO2 and NOx, or freeway CALINE4 NOx we estimated a reduction in biparietal diameter of 0.2-0.3mm. For women residing within 5km of a monitoring station, we estimated biparietal diameter reductions of 0.9-1.0mm per IQR increase in CO and NO2. Effect estimates were robust to adjustment for a number of potential confounders. We did not observe consistent patterns for other growth endpoints we examined. Prenatal exposure to traffic-derived pollution was negatively associated with fetal head size measured as biparietal diameter in late pregnancy. Copyright © 2014 Elsevier Inc. All rights reserved.
Mode of delivery has an independent impact on neonatal condition at birth.
Prior, Tomas; Kumar, Sailesh
2014-10-01
Current intra-partum monitoring techniques are often criticized for their poor specificity, with their performance frequently evaluated using measures of the neonatal condition at birth as a surrogate marker for intra-partum fetal compromise. However, these measures may potentially be influenced by a multitude of other factors, including the mode of delivery itself. This study aimed to investigate the impact of mode of delivery on neonatal condition at birth. This prospective observational study, undertaken at a tertiary referral maternity unit in London, UK, included 604 'low risk' women recruited prior to delivery. Commonly assessed neonatal outcome variables (Apgar score at 1 and 5min, umbilical artery pH and base excess, neonatal unit admission, and a composite neonatal outcome score) were used to compare the condition at birth between babies born by different modes of delivery, using one-way ANOVA and chi-squared testing. Infants born by instrumental delivery for presumed fetal compromise had the poorest condition at birth (mean composite score=1.20), whereas those born by Cesarean section for presumed fetal compromise had a better condition at birth (mean composite score=0.64) (p=<0.001). No difference in composite neonatal outcome scores was observed between babies born by instrumental delivery for a prolonged second stage (no evidence of compromise), and those born by Cesarean delivery for presumed fetal compromise. Mode of delivery represents a potential confounding factor when using condition at birth as a surrogate marker of intra-partum fetal compromise. When evaluating the efficacy of intra-partum monitoring techniques, the isolated use of Apgar scores, umbilical artery acidosis and neonatal unit admission should be discouraged. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Prenatal Air Pollution Exposure and Ultrasound Measures of Fetal Growth in Los Angeles, California
Ritz, Beate; Qiu, Jiaheng; Lee, Pei-Chen; Lurmann, Fred; Penfold, Bryan; Weiss, Robert Erin; McConnell, Rob; Arora, Chander; Hobel, Calvin; Wilhelm, Michelle
2014-01-01
Background Few previous studies examined the impact of prenatal air pollution exposures on fetal development based on ultrasound measures during pregnancy. Methods In a prospective birth cohort of more than 500 women followed during 1993-1996 in Los Angeles, California, we examined how air pollution impacts fetal growth during pregnancy. Exposure to traffic related air pollution was estimated using CALINE4 air dispersion modeling for nitrogen oxides (NOx) and a land use regression (LUR) model for nitrogen monoxide (NO), nitrogen dioxide (NO2) and NOx. Exposures to carbon monoxide (CO), NO2, ozone (O3) and particles <10 μm in aerodynamic diameter (PM10) were estimated using government monitoring data. We employed a linear mixed effects model to estimate changes in fetal size at approximately 19, 29 and 37 weeks gestation based on ultrasound. Results Exposure to traffic-derived air pollution during 29 to 37 weeks was negatively associated with biparietal diameter at 37 weeks gestation. For each interquartile range (IQR) increase in LUR-based estimates of NO, NO2 and NOx, or freeway CALINE4 NOx we estimated a reduction in biparietal diameter of 0.2-0.3 mm. For women residing within 5 km of a monitoring station, we estimated biparietal diameter reductions of 0.9-1.0 mm per IQR increase in CO and NO2. Effect estimates were robust to adjustment for a number of potential confounders. We did not observe consistent patterns for other growth endpoints we examined. Conclusions Prenatal exposure to traffic-derived pollution was negatively associated with fetal head size measured as biparietal diameter in late pregnancy. PMID:24517884
Payne, Beth A; Kyle, Phillipa M; Lim, Kenneth; Lisonkova, Sarka; Magee, Laura A; Pullar, Barbra; Qu, Ziguang; von Dadelszen, Peter
2013-07-01
Pre-eclampsia is associated with increased risk to both the mother and fetus. Effective monitoring of the fetal condition is essential to the management of women with pre-eclampsia. The biophysical profile (BPP) is one monitoring tool available to clinicians. To compare the BPP test with cardiotocography/non-stress test (CTG/NST) alone for their ability to predict fetal acidemia at birth or a composite adverse perinatal outcome among women with preeclampsia and to estimate the effect of BPP assessment on mode of delivery and birth outcome. Secondary analysis of a prospective cohort of women with preeclampsia. The predictive ability of the tests was assessed based on sensitivity, specificity, positive and negative likelihood ratios (LR+, LR-). Women assessed with the BPP were compared with matched controls not assessed with the BPP to determine the odds of Cesarean delivery or adverse perinatal outcomes after adjustment for potential confounders. Five out of 89 women (5.6%) had an abnormal BPP; 18 out of 89 (20.2%) had an abnormal CTG/NST. Fetal acidemia was diagnosed in 13 fetuses (14.6%); composite adverse perinatal outcome in 68 fetuses/infants (76.4%). Both tests had relatively poor predictive performance for both outcomes (LR+ between 2.50 and 3.90 and LR- between 0.64 and 0.93). Assessment with the BPP was positively associated with fetal acidemia (adjusted OR 4.84; 95% CI 1.33-17.66). The BPP and CTG/NST alone were poor predictors of perinatal outcome in this cohort; multiple tests should be considered when assessing fetal risk in women with preeclampsia. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.
Fetal Alcohol Spectrum Disorders (FASDs): Alcohol Use Quiz
... Data & Statistics State-Level Estimates 2016 Research & Tracking Monitoring Alcohol Use International Research Training & Education Online Training Past Activities Articles & Key Findings Materials & Multimedia Fact Sheets & Brochures ...
Barrett, Angela N; Xiong, Li; Tan, Tuan Z; Advani, Henna V; Hua, Rui; Laureano-Asibal, Cecille; Soong, Richie; Biswas, Arijit; Nagarajan, Niranjan; Choolani, Mahesh
2017-01-01
Cell-free DNA from maternal plasma can be used for non-invasive prenatal testing for aneuploidies and single gene disorders, and also has applications as a biomarker for monitoring high-risk pregnancies, such as those at risk of pre-eclampsia. On average, the fractional cell-free fetal DNA concentration in plasma is approximately 15%, but can vary from less than 4% to greater than 30%. Although quantification of cell-free fetal DNA is straightforward in the case of a male fetus, there is no universal fetal marker; in a female fetus measurement is more challenging. We have developed a panel of multiplexed insertion/deletion polymorphisms that can measure fetal fraction in all pregnancies in a simple, targeted sequencing reaction. A multiplex panel of primers was designed for 35 indels plus a ZFX/ZFY amplicon. cfDNA was extracted from plasma from 157 pregnant women, and maternal genomic DNA was extracted for 20 of these samples for panel validation. Sixty-one samples from pregnancies with a male fetus were subjected to whole genome sequencing on the Ion Proton sequencing platform, and fetal fraction derived from Y chromosome counts was compared to fetal fraction measured using the indel panel. A total of 157 cell-free DNA samples were sequenced using the indel panel, and informativity was assessed, along with the proportion of fetal DNA. Using gDNA we optimised the indel panel, removing amplicons giving rise to PCR bias. Good correlation was found between fetal fraction using indels and using whole genome sequencing of the Y chromosome (Spearmans r = 0.69). A median of 12 indels were informative per sample. The indel panel was informative in 157/157 cases (mean fetal fraction 14.4% (±0.58%)). Using our targeted next generation sequencing panel we can readily assess the fetal DNA percentage in male and female pregnancies.
Xiong, Li; Tan, Tuan Z.; Advani, Henna V.; Hua, Rui; Laureano-Asibal, Cecille; Soong, Richie; Biswas, Arijit; Nagarajan, Niranjan; Choolani, Mahesh
2017-01-01
Objective Cell-free DNA from maternal plasma can be used for non-invasive prenatal testing for aneuploidies and single gene disorders, and also has applications as a biomarker for monitoring high-risk pregnancies, such as those at risk of pre-eclampsia. On average, the fractional cell-free fetal DNA concentration in plasma is approximately 15%, but can vary from less than 4% to greater than 30%. Although quantification of cell-free fetal DNA is straightforward in the case of a male fetus, there is no universal fetal marker; in a female fetus measurement is more challenging. We have developed a panel of multiplexed insertion/deletion polymorphisms that can measure fetal fraction in all pregnancies in a simple, targeted sequencing reaction. Methods A multiplex panel of primers was designed for 35 indels plus a ZFX/ZFY amplicon. cfDNA was extracted from plasma from 157 pregnant women, and maternal genomic DNA was extracted for 20 of these samples for panel validation. Sixty-one samples from pregnancies with a male fetus were subjected to whole genome sequencing on the Ion Proton sequencing platform, and fetal fraction derived from Y chromosome counts was compared to fetal fraction measured using the indel panel. A total of 157 cell-free DNA samples were sequenced using the indel panel, and informativity was assessed, along with the proportion of fetal DNA. Results Using gDNA we optimised the indel panel, removing amplicons giving rise to PCR bias. Good correlation was found between fetal fraction using indels and using whole genome sequencing of the Y chromosome (Spearmans r = 0.69). A median of 12 indels were informative per sample. The indel panel was informative in 157/157 cases (mean fetal fraction 14.4% (±0.58%)). Conclusions Using our targeted next generation sequencing panel we can readily assess the fetal DNA percentage in male and female pregnancies. PMID:29084245
Time and number of displays impact critical signal detection in fetal heart rate tracings.
Anderson, Brittany L; Scerbo, Mark W; Belfore, Lee A; Abuhamad, Alfred Z
2011-06-01
Interest in centralized monitoring in labor and delivery units is growing because it affords the opportunity to monitor multiple patients simultaneously. However, a long history of research on sustained attention reveals these types of monitoring tasks can be problematic. The goal of the present experiment was to examine the ability of individuals to detect critical signals in fetal heart rate (FHR) tracings in one or more displays over an extended period of time. Seventy-two participants monitored one, two, or four computer-simulated FHR tracings on a computer display for the appearance of late decelerations over a 48-minute vigil. Measures of subjective stress and workload were also obtained before and after the vigil. The results showed that detection accuracy decreased over time and also declined as the number of displays increased. The subjective reports indicated that participants found the task to be stressful and mentally demanding, effortful, and frustrating. The results suggest that centralized monitoring that allows many patients to be monitored simultaneously may impose a detrimental attentional burden on the observer. Furthermore, this seemingly benign task may impose an additional source of stress and mental workload above what is commonly found in labor and delivery units. © Thieme Medical Publishers.
Rivenes Lafontan, Sara; Sundby, Johanne; Ersdal, Hege L.; Abeid, Muzdalifat; Kidanto, Hussein L.; Mbekenga, Columba K.
2018-01-01
To increase labor monitoring and prevent neonatal morbidity and mortality, a new wireless, strap-on electronic fetal heart rate monitor called Moyo was introduced in Tanzania in 2016. As part of the ongoing evaluation of the introduction of the monitor, the aim of this study was to explore the attitudes and perceptions of women who had worn the monitor continuously during their most recent delivery and perceptions about how it affected care. This knowledge is important to identify barriers towards adaptation in order to introduce new technology more effectively. We carried out 20 semi-structured individual interviews post-labor at two hospitals in Tanzania. A thematic content analysis was used to analyze the data. Our results indicated that the use of the monitor positively affected the women’s birth experience. It provided much-needed reassurance about the wellbeing of the child. The women considered that wearing Moyo improved care due to an increase in communication and attention from birth attendants. However, the women did not fully understand the purpose and function of the device and overestimated its capabilities. This highlights the need to improve how and when information is conveyed to women in labor. PMID:29425167
Del Gaudio, Costantino; Carotti, Adriano; Grigioni, Mauro; Morbiducci, Umberto
2012-05-01
Fetal cardiac surgery (FCS) represents a challenging issue for the in utero treatment of congenital heart defects. However, FCS has still not gained the sufficient reliability for clinical practice due to an incompletely elucidated fetal stress response. For example, blood sampling can contribute to its onset, leading to fetoplacental unit dysfunction, one of the main causes of failure of the surgical procedure. In order to address this issue, the role of the autonomic control system during an experimental procedure of cardiac bypass on ewe fetuses was investigated by means of recurrence quantification analysis (RQA), a well-recognized method for the analysis of nonlinear systems. RQA was applied to time series extracted from fetal arterial pressure recordings before and after the cardiac bypass established by means of an extracorporeal circuit, including an axial blood pump, and taking advantage of the capability of the placenta to work as a natural oxygenator. Statistically significant correlations were found among RQA-based metrics and fetal blood gas data, suggesting the possibility to infer the clinical status of the fetus starting from its hemodynamic signals.This study shows the relevance of RQA as a complementary tool for the monitoring of the fetal status during cardiac bypass.
Pecks, Ulrich; Wölter, Manja; Borchers, Christoph; Smith, Derek; Maass, Nicolai; Glocker, Michael; Rath, Werner
2013-04-01
Fetal umbilical cord HDL concentration is lower in IUGR neonates as compared to gestational age matched controls (CTRL). The causes by now are unknown. A full apolipoprotein analysis of cord blood might help in understanding the changes in lipid metabolism seen in IUGR. To characterize cord blood apolipoprotein profile of IUGR neonates. Serum of venous umbilical cord blood (15 IUGR vs. 15 CTRL) was analyzed by Multiple Reaction Monitoring (MRM). 15 different known apolipoproteins were profiled. HDL and LDL were measured by colorimetric methods in fetal cord blood and their corresponding mothers. Fetal HDL (p<0.0001), ApoC1 (p<0.0001), and ApoE (p=0.0001) levels were lower in IUGR as compared to CTRL. Fetal HDL levels were positive correlated to ApoE, ApoC1, and ApoA2 (r=0.79, r=0.74, r=0.56). Fetal LDL levels were positive correlated to ApoB, ApoE, ApoA2, and ApoC3 (r=0.74, r=0.67, r=0.57, r=0.55). Maternal LDL concentrations correlated positive to fetal ApoC1, ApoC2, and LCAT-concentration (r=0.54, r=0.52, r=0.52). The results underlines the relevance of ApoE in fetal development. Moreover, we speculate that maternal lipid profile has an impact on fetal lipid metabolisms as evidenced by the association of maternal LDL levels and fetal ApoC1, ApoC2, and LCAT concentrations. This observation requires further confirmation and is worth to be analyzed since it provides a mechanistic link for therapeutic options. Copyright © 2013. Published by Elsevier B.V.
Noninvasive Fetal Electrocardiography Part II: Segmented-Beat Modulation Method for Signal Denoising
Agostinelli, Angela; Sbrollini, Agnese; Burattini, Luca; Fioretti, Sandro; Di Nardo, Francesco; Burattini, Laura
2017-01-01
Background: Fetal well-being evaluation may be accomplished by monitoring cardiac activity through fetal electrocardiography. Direct fetal electrocardiography (acquired through scalp electrodes) is the gold standard but its invasiveness limits its clinical applicability. Instead, clinical use of indirect fetal electrocardiography (acquired through abdominal electrodes) is limited by its poor signal quality. Objective: Aim of this study was to evaluate the suitability of the Segmented-Beat Modulation Method to denoise indirect fetal electrocardiograms in order to achieve a signal-quality at least comparable to the direct ones. Method: Direct and indirect recordings, simultaneously acquired from 5 pregnant women during labor, were filtered with the Segmented-Beat Modulation Method and correlated in order to assess their morphological correspondence. Signal-to-noise ratio was used to quantify their quality. Results: Amplitude was higher in direct than indirect fetal electrocardiograms (median:104 µV vs. 22 µV; P=7.66·10-4), whereas noise was comparable (median:70 µV vs. 49 µV, P=0.45). Moreover, fetal electrocardiogram amplitude was significantly higher than affecting noise in direct recording (P=3.17·10-2) and significantly in indirect recording (P=1.90·10-3). Consequently, signal-to-noise ratio was initially higher for direct than indirect recordings (median:3.3 dB vs. -2.3 dB; P=3.90·10-3), but became lower after denoising of indirect ones (median:9.6 dB; P=9.84·10-4). Eventually, direct and indirect recordings were highly correlated (median: ρ=0.78; P<10-208), indicating that the two electrocardiograms were morphologically equivalent. Conclusion: Segmented-Beat Modulation Method is particularly useful for denoising of indirect fetal electrocardiogram and may contribute to the spread of this noninvasive technique in the clinical practice. PMID:28567129
Lv, Jiaxuan; Wang, Wei; Li, Yuehong
2015-08-01
To define the outcomes and risk predictors of fetal and maternal consequences of pregnancy in lupus nephritis (LN) patients. Maternal and fetal outcomes of pregnancy in 52 systemic lupus erythematosus (SLE) patients were observed. Patients were allocated into two groups according to the presence or absence of LN. LN patients were subject to a higher risk of fetal complications, including fetal loss (7/24, 29.2 %, P = 0.001), lower birth weight (2548.2 ± 540.8 vs. 2949.1 ± 592.6 g, P = 0.028) and a higher frequency of small for gestational age births (33.3 vs. 10.7 %, P = 0.002). Higher rates of lupus flares (83.3 vs. 21.4 %, P = 0.001) and increased LAI-P scores (0.65 ± 0.36 vs. 0.21 ± 0.27, P = 0.001) during pregnancy were observed in LN patients. Multivariate analysis showed that increased SLE activity (P = 0.02, OR 4.2, 95 % CI 1.2-14.5), renal damage (P = 0.001, OR 8.4, 95 % CI 2.2-31.8), hypocomplementemia (P = 0.05, OR 3.23, 95 % CI 1.0-10.7), hypoalbuminemia (P = 0.011, OR 5.62, 95 % CI 1.4-23.0) and hypertension (P = 0.021, OR 6.0, 95 % CI 1.5-24.2) during pregnancy were predictors of adverse fetal outcomes. Pregnancy in LN patients should be monitored before and during pregnancy because of poor fetal and maternal outcomes. Increased LAI-P scores, renal damage, hypocomplementemia, hypoalbuminemia and hypertension are predictors of adverse fetal outcomes for SLE patients.
Banigé, Maïa; Estellat, Candice; Biran, Valerie; Desfrere, Luc; Champion, Valerie; Benachi, Alexandra; Ville, Yves; Dommergues, Marc; Jarreau, Pierre-Henri; Mokhtari, Mostafa; Boithias, Claire; Brioude, Frederic; Mandelbrot, Laurent; Ceccaldi, Pierre-François; Mitanchez, Delphine; Polak, Michel; Luton, Dominique
2017-06-01
Neonatal hyperthyroidism was first described in 1912 and in 1964 was shown to be linked to transplacental passage of maternal antibodies. Few multicenter studies have described the perinatal factors leading to fetal and neonatal dysthyroidism. To show how fetal dysthyroidism (FD) and neonatal dysthyroidism (ND) can be predicted from perinatal variables, in particular, the levels of anti-thyrotropin receptor antibodies (TRAbs) circulating in the mother and child. This was a retrospective multicenter study of data from the medical records of all patients monitored for pregnancy from 2007 to 2014. Among 280,000 births, the medical records of 2288 women with thyroid dysfunction were selected and screened, and 417 women with Graves disease and positive for TRAbs during pregnancy were included. Using the maternal TRAb levels, the cutoff value of 2.5 IU/L best predicted for FD, with a sensitivity of 100% and specificity of 64%. Using the newborn TRAb levels, the cutoff value of 6.8 IU/L best predicted for ND, with a sensitivity of 100% and a specificity of 94%. In our study, 65% of women with a history of Graves disease did not receive antithyroid drugs during pregnancy but still had infants at risk of ND. In pregnant women with TRAb levels ≥2.5 IU/L, fetal ultrasound monitoring is essential until delivery. All newborns with TRAb levels ≥6.8 IU/L should be examined by a pediatrician with special attention for thyroid dysfunction and treated, if necessary.
Importance of a multidisciplinary approach and monitoring in fetal warfarin syndrome.
Silveira, Daniélle B; da Rosa, Ernani B; de Mattos, Vinicius F; Goetze, Thayse B; Sleifer, Pricila; Santa Maria, Fernanda D; Rosa, Rosana C M; Rosa, Rafael F M; Zen, Paulo R G
2015-06-01
Warfarin is a synthetic oral anticoagulant that crosses the placenta and can lead to a number of congenital abnormalities known as fetal warfarin syndrome. Our aim is to report on the follow-up from birth to age 8 years of a patient with fetal warfarin syndrome. He presented significant respiratory dysfunction, as well as dental and speech and language complications. The patient was the second child of a mother who took warfarin during pregnancy due to a metallic heart valve. The patient had respiratory dysfunction at birth. On physical examination, he had a hypoplastic nose, pectus excavatum, and clubbing of the fingers. Nasal fibrobronchoscopy showed upper airway obstruction due to narrowing of the nasal cavities. He underwent surgical correction with Max Pereira graft, zetaplasty, and osteotomies for the piriform aperture. At dental evaluation, he had caries and delayed eruption of the upper incisors. Speech and language assessment revealed high palate, mouth breathing, little nasal patency, and shortened upper lip. Auditory long latency and cognitive-related potential to auditory stimuli demonstrated functional changes in the cortical auditory pathways. We believe that the frequency of certain findings observed in our patient may be higher in fetal warfarin syndrome than is appreciated, since a significant number result in abortions, stillbirths, or children evaluated in the first year of life without a follow-up. Thus, a multidisciplinary approach and long-term monitoring of these patients may be necessary. © 2015 Wiley Periodicals, Inc.
The role of neuropeptide Y in the ovine fetal cardiovascular response to reduced oxygenation
Sanhueza, Emilia M; Johansen-Bibby, Anja A; Fletcher, Andrew J W; Riquelme, Raquel A; Daniels, Alejandro J; Serón-Ferré, Maria; Gaete, Cristián R; Carrasco, Jorge E; Llanos, Aníbal J; Giussani, Dino A
2003-01-01
This study investigated the role of neuropeptide Y (NPY) in mediating cardiovascular responses to reduced oxygenation in the late gestation ovine fetus by: (1) comparing the effects on the cardiovascular system of an exogenous infusion of NPY with those elicited by moderate or severe reductions in fetal oxygenation; and (2) determining the effect of fetal i.v. treatment with a selective NPY-Y1 receptor antagonist on the fetal cardiovascular responses to acute moderate hypoxaemia. Under general anaesthesia, 14 sheep fetuses (0.8–0.9 of gestation) were surgically prepared with vascular and amniotic catheters. In 5 of these fetuses, a Transonic flow probe was also implanted around a femoral artery. Following at least 5 days of recovery, one group of fetuses (n = 9) was subjected to a 30 min treatment period with exogenous NPY (17 μg kg−1 bolus plus 0.85 μg kg−1 min−1 infusion). In this group, fetal blood pressure and heart rate were monitored continuously and the distribution of the fetal combined ventricular output was assessed via injection of radiolabelled microspheres before and during treatment. The second group of fetuses instrumented with the femoral flow probe (n = 5) were subjected to a 3 h experiment consisting of 1 h of normoxia, 1 h of hypoxaemia, and 1 h of recovery during a slow i.v. infusion of vehicle. One or two days later, the acute hypoxaemia protocol was repeated during fetal i.v. treatment with a selective NPY-Y1 receptor antagonist (50 μg kg−1bolus + 1.5 μg kg−1 min−1 infusion). In these fetuses, fetal arterial blood pressure, heart rate and femoral vascular resistance were recorded continuously. The results show that fetal treatment with exogenous NPY mimics the fetal cardiovascular responses to asphyxia, and that treatment of the sheep fetus with a selective NPY-Y1 receptor antagonist does not affect the fetal cardiovascular response to acute moderate hypoxaemia. These results support a greater role for NPY in mediating the fetal cardiovascular responses to acute asphyxia than to acute moderate hypoxaemia. PMID:12563013
Uromodulin: a new biomarker of fetal renal function?
Botelho, Thais Emanuelle Faria; Pereira, Alamanda Kfoury; Teixeira, Patrícia Gonçalves; Lage, Eura Martins; Osanan, Gabriel Costa; Silva, Ana Cristina Simões E
2016-12-01
Obstructive uropathies are main diseases affecting the fetus. Early diagnosis allows to establish the appropriate therapy to minimize the risk of damage to kidney function at birth. Biochemical markers have been used to predict the prognosis of renal function in fetuses. Uromodulin, also known by Tamm-Horsfall protein (THP) is exclusively produced in the kidneys and in normal conditions is the protein excreted in larger amounts in human urine. It plays important roles in kidneys and urinary tract. Also it participates in ion transport processes, interact with various components of the immune system and has a role in defense against urinary tract infections. Moreover, this protein was proved to be a good marker of renal function in adult patients with several renal diseases. To evaluate if uromodulin is produced and eliminated by the kidneys during fetal life by analyzing fetal urine and amniotic fluid and to establish correlation with biochemical parameter of renal function already used in Fetal Medicine Center at the Clinic Hospital of UFMG (CEMEFE/HC). Between 2013 and 2015, were selected 29 fetuses with indication of invasive tests for fetal diagnosis in monitoring at the CEMEFE/HC. The determination of uromodulin was possible and measurable in all samples and showed statistically significant correlation with the osmolarity. There was a tendency of lower levels of Uromodulin values in fetuses with severe renal impairment prenatally. Thus, high levels of this protein in fetal amniotic fluid or fetal urine dosages possibly mean kidney function preserved.
Statham, H; Solomou, W; Green, J
2006-12-01
UK abortion law allows terminations for fetal abnormality without gestational limit. This study aimed to understand the decision-making experiences of fetal medicine professionals working within this legal framework. Qualitative study using semistructured interviews. Four English fetal medicine units. Fifteen doctors and midwives working in fetal medicine units and the Director of a related voluntary sector group. Thematic analysis of transcribed interviews. Attitudes to abortion legislation; how decisions are made about the offer of late abortion and feticide. Fetal medicine specialists acknowledged the difficulties of ensuring that they worked within the law and within their own ethical frameworks when making decisions about offering terminations after viability. Practice regarding which abnormalities meet the legal criteria appeared to be governed largely by consensus between colleagues within their own and other units and in discussion with other specialists. Study participants reported individual differences about abnormalities where they personally would not wish to be involved in a termination, and also noted a shift in general attitudes over time as to conditions that meet the legal criteria. A proscribed list was believed to be both unworkable, given the variability in diagnoses and unhelpful, leading to reduced patient care. Research is needed to monitor attitudes to, and interpretation of, UK abortion legislation, which permits termination after a late diagnosis of fetal abnormality without gestational limit. If attitudes are changing, it is important to understand why, and what the consequences will be for parents and for health professionals.
A novel method of mouse ex utero transplantation of hepatic progenitor cells into the fetal liver
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shikanai, Mima; Asahina, Kinji; Iseki, Sachiko
2009-04-03
Avoiding the limitations of the adult liver niche, transplantation of hepatic stem/progenitor cells into fetal liver is desirable to analyze immature cells in a hepatic developmental environment. Here, we established a new monitor tool for cell fate of hepatic progenitor cells transplanted into the mouse fetal liver by using ex utero surgery. When embryonic day (ED) 14.5 hepatoblasts were injected into the ED14.5 fetal liver, the transplanted cells expressed albumin abundantly or {alpha}-fetoprotein weakly, and contained glycogen in the neonatal liver, indicating that transplanted hepatoblasts can proliferate and differentiate in concord with surrounding recipient parenchymal cells. The transplanted cells becamemore » mature in the liver of 6-week-old mice. Furthermore, this method was applicable to transplantation of hepatoblast-like cells derived from mouse embryonic stem cells. These data indicate that this unique technique will provide a new in vivo experimental system for studying cell fate of hepatic stem/progenitor cells and liver organogenesis.« less
Ugwumadu, A
2014-08-01
Original interpretations of fetal heart rate (FHR) patterns equated FHR decelerations with 'fetal distress', requiring expeditious delivery. This simplistic interpretation is still implied in our clinical guidelines despite 40 years of increasing understanding of the behaviour and regulation of the fetal cardiovascular system during labour. The physiological basis of FHR responses and adaptations to oxygen deprivation is de-emphasised, whilst generations of obstetricians and midwives are trained to focus on, and classify, the morphological appearances of decelerations into descriptive categories, with no attempt to understand how the fetus defends itself and compensates for intrapartum hypoxic ischaemic insults, or the patterns that suggest progressive loss of compensation. Consequently, there is a lack of confidence, marked variation in FHR interpretation, defensive practices, unnecessary operative interventions, and a failure to recognise abnormal FHR patterns, resulting in adverse outcomes and expensive litigation. © 2014 Royal College of Obstetricians and Gynaecologists.
Song, Shuang; Rooijakkers, Michael; Harpe, Pieter; Rabotti, Chiara; Mischi, Massimo; van Roermund, Arthur H M; Cantatore, Eugenio
2015-04-01
This paper presents a low-voltage current-reuse chopper-stabilized frontend amplifier for fetal ECG monitoring. The proposed amplifier allows for individual tuning of the noise in each measurement channel, minimizing the total power consumption while satisfying all application requirements. The low-voltage current reuse topology exploits power optimization in both the current and the voltage domain, exploiting multiple supply voltages (0.3, 0.6 and 1.2 V). The power management circuitry providing the different supplies is optimized for high efficiency (peak charge-pump efficiency = 90%).The low-voltage amplifier together with its power management circuitry is implemented in a standard 0.18 μm CMOS process and characterized experimentally. The amplifier core achieves both good noise efficiency factor (NEF=1.74) and power efficiency factor (PEF=1.05). Experiments show that the amplifier core can provide a noise level of 0.34 μVrms in a 0.7 to 182 Hz band, consuming 1.17 μW power. The amplifier together with its power management circuitry consumes 1.56 μW, achieving a PEF of 1.41. The amplifier is also validated with adult ECG and pre-recorded fetal ECG measurements.
2014-01-01
Background In 2006 WHO presented the infant and child growth charts suggested for universal application. However, major determinants for perinatal outcomes and postnatal growth are laid down during antenatal development. Accordingly, monitoring fetal growth in utero by ultrasonography is important both for clinical and scientific reasons. The currently used fetal growth references are derived mainly from North American and European population and may be inappropriate for international use, given possible variances in the growth rates of fetuses from different ethnic population groups. WHO has, therefore, made it a high priority to establish charts of optimal fetal growth that can be recommended worldwide. Methods This is a multi-national study for the development of fetal growth standards for international application by assessing fetal growth in populations of different ethnic and geographic backgrounds. The study will select pregnant women of high-middle socioeconomic status with no obvious environmental constraints on growth (adequate nutritional status, non-smoking), and normal pregnancy history with no complications likely to affect fetal growth. The study will be conducted in centres from ten developing and industrialized countries: Argentina, Brazil, Democratic Republic of Congo, Denmark, Egypt, France, Germany, India, Norway, and Thailand. At each centre, 140 pregnant women will be recruited between 8 + 0 and 12 + 6 weeks of gestation. Subsequently, visits for fetal biometry will be scheduled at 14, 18, 24, 28, 32, 36, and 40 weeks (+/− 1 week) to be performed by trained ultrasonographers. The main outcome of the proposed study will be the development of fetal growth standards (either global or population specific) for international applications. Discussion The data from this study will be incorporated into obstetric practice and national health policies at country level in coordination with the activities presently conducted by WHO to implement the use of the Child Growth Standards. PMID:24886101
[Excrement of the meconium and the intra-partum cardiotocogram].
Santeler, P; Hochuli, E
1976-01-01
Of 2233 parturients, 170 cases with evidence of meconium during delivery were examined. We tried to establish the correlation between the appearance of meconium and the occurance of contraction induced FHR-decelerations in continuous intra partum monitoring. In addition we purposed to determine, whether the appearing of meconium during labor can be used as a clinical prognosite sign for fetal outcome. Our data support the assumption that the passage of meconium during any stage of labor only represents a sign of potential fetal distress showing the intra partum records pathology FHF-patterns. The appearance of meconium alone -- diagnosed at the time of the entrance of parturients or in an advanced stage of labor -- demands supplemented diagnostic methods for a better interpreting of an actual or compensated fetal distress.
Zheleznyak, Alexander; Garbow, Joel R; Neeman, Michal; Lapi, Suzanne E
2015-01-01
The goal of this work was to study the efficacy of the positron emission tomography (PET) tracers 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) and 64Cu-diacetyl-bis(N4-methylthiosemicarbazone) ([64Cu]ATSM) and in monitoring placental and fetal functional response to acute hyperoxia in late-term pregnant mice subjected to experimentally induced chronic hypoxia. E15 mice were maintained at 12% inspired oxygen for 72 hours and then imaged during oxygen inhalation with either [18F]FDG to monitor nutrient transport or 64Cu-ATSM to establish the presence of hypoxia. Computed tomography (CT) with contrast allowed clear visualization of both placentas and fetuses. The average ratio of fetal to placental [18F]FDG uptake was 0.45 ± 0.1 for the hypoxic animals and 0.55 ± 0.1 for the normoxic animals, demonstrating a significant decrease (p = .0002) in placental function in dams exposed to chronic hypoxic conditions. Hypoxic placentas and fetuses retained more 64Cu-ATSM compared to normoxic placentas and fetuses. Herein we report first-in-mouse PET imaging of fetuses employing both tracers [18F]FDG (metabolism) and 64Cu-ATSM (hypoxia). [18F]FDG PET/CT imaging allowed clear visualization of placental-fetal structures and supported quantification of tracer uptake, making this a sensitive tool for monitoring placental function in preclinical rodent models. These measurements illustrate the potentially irreversible damage generated by chronic exposure to hypoxia, which cannot be corrected by acute exposure to hyperoxia.
Kennelly, Máiréad M; Sturgiss, Stephen N
2007-01-01
To evaluate a strategy of daily biophysical profile (BPP) for pregnancies with small-for-gestational-age twins and with absent or reversed end diastolic flow (AREDF) in the umbilical artery of one twin and to assess the latency interval between detection and delivery in monochorionic (MC) and dichorionic (DC) twin pregnancy. A search of the Fetal Medicine Database was carried out between 2000 and 2005 at a single tertiary centre to identify all cases with AREDF in the umbilical artery with one small-for-gestational-age twin. Active monitoring with daily BPP was undertaken, once the estimated fetal weights (EFW) was >or= 500 g and at a gestational age of >or= 24 weeks in both twins. Delivery was timed on the basis of an abnormal BPP, two equivocal BPP within 12 h or gestational age of >or= 32(+0) weeks. Twenty-two MC and 17 DC twin pregnancies were identified. There were no fetal losses in the viable actively monitored MC (19) and DC (13) twins. There was a longer latency interval in the MC group at 21.7 days versus 14.4 days in the DC group (p = 0.13). Delivery was indicated for an abnormal BPP (57.8% MC vs 30.8% DC). A strategy of daily BPP can be used to monitor preterm twin fetuses with AREDF, prolonging pregnancy with an acceptable perinatal outcome. Copyright 2007 John Wiley & Sons, Ltd.
[Aneurysm of the ascending aorta, hyperthyroidism and pregnancy. Case report].
Zavala-Barrios, Berenice; García-Castanedo, Carla; Viruez-Soto, José Antonio; Briones-Garduño, Jesús Carlos; Coronel-Cruz, Fausto
2015-10-01
Aortic aneurysms are a rare condition in childhood and youth, etiology, evolution, natural progression and prognosis in pregnancy unknown. Hyperthyroidism occurs when there is a synthesis and/or excessive secretion of thyroid hormones during pregnancy poses difficulty for diagnosis. The new monitoring hemodynamics in pregnancy by transthoracic bioimpedance is a feasible alternative, noninvasive and real-time hemodynamic monitoring pregnant women. Primiparity 18, is referred to present tachycardia, hyperthyroidism is diagnosed and drug treatment is initiated with antithyroid from week 14.1 echocardiogram reports bivalve aortic aneurysm in the sinus of Valsalva is performed. He was determined to continue the same under strict hemodynamic and fetal monitoring. Pregnancy concludes at the end obtained through the abdomen, at 40.4 weeks, with male product, weight 2250 g, Apgar 9/9, with growth restriction type I. The mother and baby were discharged simultaneously without complications. The hyperdynamic state of pregnant patients in hyperthyroidism and aneurysms is complex and potentially complicable is why the hemodynamic patient monitoring is essential to detect changes in it that endanger the life of the binomial to this condition. Heart disease and hyperthyroidism, in this case, consistent with a fetal complications level is described as intrauterine growth restriction, however narrow and multidisciplinary monitoring and timely interventions binomial lead to satisfactory results in this case.
Sapin, E; Mahieu, D; Borgnon, J; Douvier, S; Carricaburu, E; Sagot, P
2000-04-01
Despite dramatic improvement in survival rate for neonates with gastroschisis, significant postoperative morbidity and a low mortality rate still occur. Furthermore, even in recent publications, some fetal death has been reported. Does this mean that antenatal diagnosis of gastroschisis is a missed opportunity? In fact, decreased amniotic fluid (AF) volume is observed in some fetuses with gastroschisis. However, oligohydramnios is associated with an increased risk of fetal suffering. When severe oligohydramnios is observed, intrapartum amnioinfusion, to restore AF volume, may help avoid fetal complications. Two fetuses with gastroschisis and severe oligohydramnios were treated antenatally with amnioinfusion of saline solution. In one case, fetal heart beat decelerations were observed at 27 weeks' gestation among with the oligohydroamnios and serial transabdominal amnioinfusions were performed. In the second case, severe oligohydramnios was observed at 31, weeks and an amnioinfusion was performed. The 2 babies were delivered at 31 and 34 weeks, respectively. In both cases, exteriorized bowel was nearly normal at birth, and primary closure could be performed. Outcome was favorable, and they were discharged home on day 43 and day 54, respectively. Because fetuses with gastroschisis and oligohydramnios are part of a particular high-risk group, serial ultrasound examination and computerized fetal heart beat monitoring are necessary during the third trimester. In selected cases of gastroschisis associated with severe oligohydramnios, serial amnioinfusion may be required.
Billeci, Lucia; Varanini, Maurizio
2017-01-01
The non-invasive fetal electrocardiogram (fECG) technique has recently received considerable interest in monitoring fetal health. The aim of our paper is to propose a novel fECG algorithm based on the combination of the criteria of independent source separation and of a quality index optimization (ICAQIO-based). The algorithm was compared with two methods applying the two different criteria independently—the ICA-based and the QIO-based methods—which were previously developed by our group. All three methods were tested on the recently implemented Fetal ECG Synthetic Database (FECGSYNDB). Moreover, the performance of the algorithm was tested on real data from the PhysioNet fetal ECG Challenge 2013 Database. The proposed combined method outperformed the other two algorithms on the FECGSYNDB (ICAQIO-based: 98.78%, QIO-based: 97.77%, ICA-based: 97.61%). Significant differences were obtained in particular in the conditions when uterine contractions and maternal and fetal ectopic beats occurred. On the real data, all three methods obtained very high performances, with the QIO-based method proving slightly better than the other two (ICAQIO-based: 99.38%, QIO-based: 99.76%, ICA-based: 99.37%). The findings from this study suggest that the proposed method could potentially be applied as a novel algorithm for accurate extraction of fECG, especially in critical recording conditions. PMID:28509860
Liu, Hai Lun; Garzoni, Luca; Herry, Christophe; Durosier, Lucien Daniel; Cao, Mingju; Burns, Patrick; Fecteau, Gilles; Desrochers, André; Patey, Natalie; Seely, Andrew J E; Faure, Christophe; Frasch, Martin G
2016-04-01
Necrotizing enterocolitis of the neonate is an acute inflammatory intestinal disease that can cause necrosis and sepsis. Chorioamnionitis is a risk factor of necrotizing enterocolitis. The gut represents the biggest vagus-innervated organ. Vagal activity can be measured via fetal heart rate variability. We hypothesized that fetal heart rate variability can detect fetuses with incipient gut inflammation. Prospective animal study. University research laboratory. Chronically instrumented near-term fetal sheep (n = 21). Animals were surgically instrumented with vascular catheters and electrocardiogram to allow manipulation and recording from nonanesthetized animals. In 14 fetal sheep, inflammation was induced with lipopolysaccharide (IV) to mimic chorioamnionitis. Fetal arterial blood samples were drawn at selected time points over 54 hours post lipopolysaccharide for blood gas and cytokines (interleukin-6 and tumor necrosis factor-α enzymelinked immunosorbent assay). Fetal heart rateV was quantified throughout the experiment. The time-matched fetal heart rate variability measures were correlated to the levels of interleukin-6 and tumor necrosis factor-α. Upon necropsy, ionized calcium binding adaptor molecule 1+ (Iba1+), CD11c+ (M1), CD206+ (M2 macrophages), and occludin (leakiness marker) immunofluorescence in the terminal ileum was quantified along with regional Iba1+ signal in the brain (microglia). Interleukin-6 peaked at 3 hours post lipopolysaccharide accompanied by mild cardiovascular signs of sepsis. At 54 hours, we identified an increase in Iba1+ and, specifically, M1 macrophages in the ileum accompanied by increased leakiness, with no change in Iba1 signal in the brain. Preceding this change on tissue level, at 24 hours, a subset of nine fetal heart rate variability measures correlated exclusively to the Iba+ markers of ileal, but not brain, inflammation. An additional fetal heart rate variability measure, mean of the differences of R-R intervals, correlated uniquely to M1 ileum macrophages increasing due to lipopolysaccharide. We identified a unique subset of fetal heart rate variability measures reflecting 1.5 days ahead of time the levels of macrophage activation and increased leakiness in terminal ileum. We propose that such subset of fetal heart rate variability measures reflects brain-gut communication via the vagus nerve. Detecting such noninvasively obtainable organ-specific fetal heart rate variability signature of inflammation would alarm neonatologists about neonates at risk of developing necrotizing enterocolitis and sepsis. Clinical validation studies are required.
Thyroid hormone is required for growth adaptation to pressure load in the ovine fetal heart.
Segar, Jeffrey L; Volk, Ken A; Lipman, Michael H B; Scholz, Thomas D
2013-03-01
Thyroid hormone exerts broad effects on the adult heart, but little is known regarding the role of thyroid hormone in the regulation of cardiac growth early in development and in response to pathophysiological conditions. To address this issue, we determined the effects of fetal thyroidectomy on cardiac growth and growth-related gene expression in control and pulmonary-artery-banded fetal sheep. Fetal thyroidectomy (THX) and/or placement of a restrictive pulmonary artery band (PAB) were performed at 126 ± 1 days of gestation (term, 145 days). Four groups of animals [n = 5-6 in each group; (i) control; (ii) fetal THX; (iii) fetal PAB; and (iv) fetal PAB + THX] were monitored for 1 week prior to being killed. Fetal heart rate was significantly lower in the two THX groups compared with the non-THX groups, while mean arterial blood pressure was similar among groups. Combined left and right ventricle free wall + septum weight, expressed per kilogram of fetal weight, was significantly increased in PAB (6.27 ± 0.85 g kg(-1)) compared with control animals (4.72 ± 0.12 g kg(-1)). Thyroidectomy significantly attenuated the increase in cardiac mass associated with PAB (4.94 ± 0.13 g kg(-1)), while THX alone had no detectable effect on heart mass (4.95 ± 0.27 g kg(-1)). The percentage of binucleated cardiomyocytes was significantly decreased in THX and PAB +THX groups (∼16%) compared with the non-THX groups (∼27%). No differences in levels of activated Akt, extracellular signal-regulated kinase or c-Jun N-terminal kinase were detected among the groups. Markers of cellular proliferation but not apoptosis or expression of growth-related genes were lower in the THX and THX+ PAB groups relative to thyroid-intact animals. These findings suggest that in the late-gestation fetal heart, thyroid hormone has important cellular growth functions in both physiological and pathophysiological states. Specifically, thyroid hormone is required for adaptive fetal cardiac growth in response to pressure overload.
Three-dimensional growth dynamics of the liver in the human fetus.
Szpinda, Michał; Paruszewska-Achtel, Monika; Woźniak, Alina; Badura, Mateusz; Mila-Kierzenkowska, Celestyna; Wiśniewski, Marcin
2015-07-01
The fetal liver is indubitably the earliest and the most severely affected organ by abnormal fetal growth. The size of the fetal liver assessed by three-dimensional ultrasonography is indispensable in determining the status of fetal growth, nutrition and maturity, and in the early recognition and monitoring fetal micro- and macrosomias. The aim of the present study was to measure the human fetal liver length, transverse and sagittal diameters to establish their age-specific reference intervals, the 3rd, 10th, 50th, 90th, and 97th smoothed centile curves, and the relative growth of the liver calculated for the 50th centile. Using anatomical, digital (NIS-Elements AR 3.0, Nikon) and statistical methods (one-way ANOVA test for paired data and post hoc RIR Tukey test, Shapiro-Wilk test, Fisher's test, Student's t test, the Altman-Chitty method), length, transverse and sagittal diameters of the liver for the 3rd, 10th, 50th, 90th, and 97th centiles were assessed in 69 human fetuses of both sexes (32 males and 37 females) aged 18-30 weeks, derived from spontaneous abortions or stillbirths. No male-female differences (P > 0.05) concerning the three parameters studied were found. During the study period, the fetal liver increased tri-dimensionally: in length from 19.51 ± 1.02 to 39.65 ± 7.05 mm, in transverse diameter from 29.44 ± 3.73 to 53.13 ± 5.31 mm, and in sagittal diameter from 22.97 ± 3.79 to 43.22 ± 5.49 mm. The natural logarithmic models were found to fit the data with gestational age (P < 0.001) in the following five cutoff points: 3rd, 10th, 50th, 90th and 97th centiles. The values of liver parameters in relation to gestational age in weeks were calculated by the following logarithmic regressions: y = -82.778 + 35.752 × ln(age) ± Z × (-2.778 + 0.308 × age) for liver length, y = -123.06 + 52.668 × ln(age) ± Z × (3.156 + 0.049 × age) for liver transverse diameter, and y = -108.94 + 46.052 × ln(age) ± Z × (-0.541 + 0.188 × age) for liver sagittal diameter. For the 50th centile, at the range of 18-30 weeks, the growth rates per week were gradually decreasing from 1.93 to 1.21 mm for length, from 2.85 to 1.79 mm for transverse diameter, and from 2.49 to 1.56 mm for sagittal diameter of the liver (P < 0.05). During the study period both the length-to-transverse diameter ratio and the sagittal-to-transverse diameter ratio of the liver changed little, attaining the values of 0.71 ± 0.11 and 0.87 ± 0.12, respectively. The fetal liver does not reveal sex differences in its length, transverse and sagittal diameters. The fetal liver length, transverse and sagittal diameters grow logarithmically. The regression equations for the estimation of the mean and standard deviation of liver length, transverse and sagittal diameters allow for calculating any desired centiles according to gestational age. The three-dimensional evolution of the fetal liver follows proportionately. The age-specific reference intervals for evolving liver length, transverse and sagittal diameters constitute the normative values of potential relevance in monitoring normal fetal development and screening for disturbances in fetal growth.
Cruz-Lemini, Mónica; Crispi, Fátima; Valenzuela-Alcaraz, Brenda; Figueras, Francesc; Gómez, Olga; Sitges, Marta; Bijnens, Bart; Gratacós, Eduard
2014-06-01
Intrauterine growth restricted (IUGR) fetuses experience cardiovascular remodeling that persists into infancy and has been related to cardiovascular outcomes in adulthood. Hypertension in infancy has been demonstrated to be a strong risk factor for later cardiovascular disease. Close monitoring together with dietary interventions have shown to improve cardiovascular health in hypertensive children; however, not all IUGR infants show increased blood pressure. We evaluated the potential of fetal echocardiography for predicting hypertension and arterial remodeling in 6-month-old IUGR infants. One hundred consecutive IUGR and 100 control fetuses were observed into infancy. Fetal assessment included perinatal Doppler imaging, cardiac morphometry, ejection fraction, cardiac output, isovolumic relaxation time (IVRT), tricuspid annular-plane systolic excursion (TAPSE), and tissue Doppler imaging. Infant hypertension and arterial remodeling were defined as mean blood pressure of >95th percentile together with aortic intima-media thickness of >75th percentile at 6 months of age. Odds ratio were obtained for fetal parameters that were associated with infant outcomes. Fetal TAPSE, right sphericity index, IVRT, and cerebroplacental ratio were the strongest predictors for postnatal vascular remodeling. A cardiovascular risk score that was based on fetal TAPSE, cerebroplacental ratio, right sphericity index, and IVRT was highly predictive of infant hypertension and arterial remodeling (area under the curve, 0.87; 95% confidence interval, 0.79-0.93; P < .001). Fetal echocardiographic parameters identify a high-risk group within the IUGR fetuses who could be targeted for early screening of blood pressure and other cardiovascular risk factors and for promoting healthy diet and physical exercise. Copyright © 2014 Mosby, Inc. All rights reserved.
Estellat, Candice; Biran, Valerie; Desfrere, Luc; Champion, Valerie; Benachi, Alexandra; Ville, Yves; Dommergues, Marc; Jarreau, Pierre-Henri; Mokhtari, Mostafa; Boithias, Claire; Brioude, Frederic; Mandelbrot, Laurent; Ceccaldi, Pierre-François; Mitanchez, Delphine; Polak, Michel; Luton, Dominique
2017-01-01
Context: Neonatal hyperthyroidism was first described in 1912 and in 1964 was shown to be linked to transplacental passage of maternal antibodies. Few multicenter studies have described the perinatal factors leading to fetal and neonatal dysthyroidism. Objective: To show how fetal dysthyroidism (FD) and neonatal dysthyroidism (ND) can be predicted from perinatal variables, in particular, the levels of anti-thyrotropin receptor antibodies (TRAbs) circulating in the mother and child. Design and Patients: This was a retrospective multicenter study of data from the medical records of all patients monitored for pregnancy from 2007 to 2014. Setting: Among 280,000 births, the medical records of 2288 women with thyroid dysfunction were selected and screened, and 417 women with Graves disease and positive for TRAbs during pregnancy were included. Results: Using the maternal TRAb levels, the cutoff value of 2.5 IU/L best predicted for FD, with a sensitivity of 100% and specificity of 64%. Using the newborn TRAb levels, the cutoff value of 6.8 IU/L best predicted for ND, with a sensitivity of 100% and a specificity of 94%. In our study, 65% of women with a history of Graves disease did not receive antithyroid drugs during pregnancy but still had infants at risk of ND. Conclusions: In pregnant women with TRAb levels ≥2.5 IU/L, fetal ultrasound monitoring is essential until delivery. All newborns with TRAb levels ≥6.8 IU/L should be examined by a pediatrician with special attention for thyroid dysfunction and treated, if necessary. PMID:29130077
Korabecna, Marie; Ulcova-Gallova, Zdenka; Horinek, Ales; Pazourková, Eva; Calda, Pavel
2014-11-01
Apoptosis of tissues of fetal origin is thought to be one of the main sources of cell-free fetal DNA (cffDNA) in maternal circulation, impaired apoptosis is also involved in the mechanisms contributing to recurrent spontaneous miscarriages (RSM) associated with antiphospholipid syndrome (APS). The APS increases the risk for preeclampsia nine times. In preeclampsia, the elevated levels of cffDNA were described by different authors. To our knowledge, cffDNA in pregnant patients with APS was never studied. In our pilot study, we focused on the levels of cffDNA in four pregnant patients with treated primary APS and compared them with values obtained in twenty-one healthy subjects of comparable gestation age (the third trimester of pregnancy). We supposed that the increase of cffDNA concentration in our treated patients would signalize the elevated apoptosis of fetal tissues as in other pathological changes of placentation. The aim of our pilot study was to determine cffDNA concentrations in patients with treated APS and to compare them with values detected in healthy pregnant women of comparable gestation age in order to discover potential non-physiological elevations in patients. The elevated values of cffDNA were not observed in our patients (p value = 0.4363, Mann-Whitney test). All patients delivered healthy children. The measurement of concentrations of cffDNA seems to be a promising tool for monitoring of therapy effectiveness in pregnant women with APS but evaluation of randomized controlled trials would be necessary to determine the specificity and the sensitivity of this test.
The current crisis in obstetrics.
Low, James A
2005-11-01
Of the issues leading to legal actions in obstetrics, the most important are events occurring before delivery that are deemed to account for the birth of a physically or mentally challenged child. In determining causation in the clinical setting, the diagnosis of fetal asphyxia can be made using blood gas and acid-base assessment. However, there are many subsidiary questions that in most cases cannot be answered, including when the asphyxia began, the severity and nature of the asphyxia during the exposure, the quality of the cardiovascular compensation, and when the brain damage occurred. When scientific proof is not available, the dilemma for the court is the requirement to reach a conclusion about the timing of brain damage on the balance of probabilities. Although it is of value, clinical risk scoring using fetal heart rate (FHR) monitoring may result in false positive predictions of fetal asphyxia. The problem in FHR monitoring is the lack of a detailed algorithm for the interpretation of FHR patterns with appropriate recommendations for management. Until such an algorithm is developed, health care workers cannot be expected to respond to fetal heart rate patterns consistently. Responsibility for the crisis in obstetrics must rest with the members of the health care disciplines who provide expert testimony. Progress made in research encourages us to assume that more is known about the causes of brain damage in the clinical setting than in fact is known. Similarly, health care professionals, parents, and lawyers often assume current methods of prediction and diagnosis to be more effective than they actually are.
The obstetric management of sickle cell disease.
Howard, Jo; Oteng-Ntim, Eugene
2012-02-01
Sickle cell disease (SCD) is the most common inherited disease worldwide and is associated with anaemia and intermittent severe pain. Pregnant women who are affected have increased maternal and fetal mortality and morbidity. In view of this obstetricians should have an awareness of this condition and its complications, and pregnancies in women with SCD should be managed by a multidisciplinary team with experience of high risk pregnancies. Ideally women should be seen preconceptually for optimisation of their SCD and partner screening. Antenatal care should include regular outpatient visits with regular monitoring for pre-eclampsia and of fetal growth. Blood transfusion should be used for the treatment of acute anaemia, acute chest syndrome or acute stroke but there is not sufficient evidence currently to recommend its use prophylactically. There is an increased prevalence of sickle crisis during pregnancy and patients should be monitored carefully throughout this time. Copyright © 2011 Elsevier Ltd. All rights reserved.
Amorim-Costa, C; Ayres-de-Campos, D; Costa-Santos, C; Bernardes, J
2014-01-01
Digital storage of cardiotocographic (CTG) tracings by fetal central monitoring systems (fCMS) obviates the need for printing, or alternatively, the tracings can be printed in regular paper instead of CTG thermal paper. We aimed at evaluating the impact of the introduction of the Omniview-SisPorto(®) system on CTG paper costs in a large university hospital. After introduction of the fCMS, there was an 87% reduction in median annual expenses with CTG paper in the labour ward (p = 0.011) and a 78% decrease in the prenatal clinic (p = 0.017), despite a more than 40% increase in the median number of observed women. Routine use of fCMS may provide an important reduction in hospital expenses associated with the use of thermal CTG paper, thus reducing the investment made in their acquisition and maintenance.
Information Theory to Probe Intrapartum Fetal Heart Rate Dynamics
NASA Astrophysics Data System (ADS)
Granero-Belinchon, Carlos; Roux, Stéphane; Abry, Patrice; Doret, Muriel; Garnier, Nicolas
2017-11-01
Intrapartum fetal heart rate (FHR) monitoring constitutes a reference tool in clinical practice to assess the baby health status and to detect fetal acidosis. It is usually analyzed by visual inspection grounded on FIGO criteria. Characterization of Intrapartum fetal heart rate temporal dynamics remains a challenging task and continuously receives academic research efforts. Complexity measures, often implemented with tools referred to as \\emph{Approximate Entropy} (ApEn) or \\emph{Sample Entropy} (SampEn), have regularly been reported as significant features for intrapartum FHR analysis. We explore how Information Theory, and especially {\\em auto mutual information} (AMI), is connected to ApEn and SampEn and can be used to probe FHR dynamics. Applied to a large (1404 subjects) and documented database of FHR data, collected in a French academic hospital, it is shown that i) auto mutual information outperforms ApEn and SampEn for acidosis detection in the first stage of labor and continues to yield the best performance in the second stage; ii) Shannon entropy increases as labor progresses, and is always much larger in the second stage;iii) babies suffering from fetal acidosis additionally show more structured temporal dynamics than healthy ones and that this progressive structuration can be used for early acidosis detection.
Fetal growth restriction: current knowledge.
Nardozza, Luciano Marcondes Machado; Caetano, Ana Carolina Rabachini; Zamarian, Ana Cristina Perez; Mazzola, Jaqueline Brandão; Silva, Carolina Pacheco; Marçal, Vivian Macedo Gomes; Lobo, Thalita Frutuoso; Peixoto, Alberto Borges; Araujo Júnior, Edward
2017-05-01
Fetal growth restriction (FGR) is a condition that affects 5-10% of pregnancies and is the second most common cause of perinatal mortality. This review presents the most recent knowledge on FGR and focuses on the etiology, classification, prediction, diagnosis, and management of the condition, as well as on its neurological complications. The Pubmed, SCOPUS, and Embase databases were searched using the term "fetal growth restriction". Fetal growth restriction (FGR) may be classified as early or late depending on the time of diagnosis. Early FGR (<32 weeks) is associated with substantial alterations in placental implantation with elevated hypoxia, which requires cardiovascular adaptation. Perinatal morbidity and mortality rates are high. Late FGR (≥32 weeks) presents with slight deficiencies in placentation, which leads to mild hypoxia and requires little cardiovascular adaptation. Perinatal morbidity and mortality rates are lower. The diagnosis of FGR may be clinical; however, an arterial and venous Doppler ultrasound examination is essential for diagnosis and follow-up. There are currently no treatments to control FGR; the time at which pregnancy is interrupted is of vital importance for protecting both the mother and fetus. Early diagnosis of FGR is very important, because it enables the identification of the etiology of the condition and adequate monitoring of the fetal status, thereby minimizing risks of premature birth and intrauterine hypoxia.
Shapiro, Karen; Miller, Melissa A; Packham, Andrea E; Aguilar, Beatriz; Conrad, Patricia A; Vanwormer, Elizabeth; Murray, Michael J
2016-03-01
Toxoplasma gondii and Sarcocystis neurona are protozoan parasites with terrestrial definitive hosts, and both pathogens can cause fatal disease in a wide range of marine animals. Close monitoring of threatened southern sea otters (Enhydra lutris nereis) in California allowed for the diagnosis of dual transplacental transmission of T. gondii and S. neurona in a wild female otter that was chronically infected with both parasites. Congenital infection resulted in late-term abortion due to disseminated toxoplasmosis. Toxoplasma gondii and S. neurona DNA was amplified from placental tissue culture, as well as from fetal lung tissue. Molecular characterization of T. gondii revealed a Type X genotype in isolates derived from placenta and fetal brain, as well as in all tested fetal organs (brain, lung, spleen, liver and thymus). This report provides the first evidence for transplacental transmission of T. gondii in a chronically infected wild sea otter, and the first molecular and immunohistochemical confirmation of concurrent transplacental transmission of T. gondii and S. neurona in any species. Repeated fetal and/or neonatal losses in the sea otter dam also suggested that T. gondii has the potential to reduce fecundity in chronically infected marine mammals through parasite recrudescence and repeated fetal infection.
Vonnahme, Kimberly A; Lemley, Caleb O
2011-01-01
As placental growth and vascularity precedes exponential fetal growth, not only is proper establishment of the placenta important, but also a continual plasticity of placental function throughout gestation. Inadequate maternal environment, such as nutritional plane, has been documented to alter fetal organogenesis and growth, thus leading to improper postnatal growth and performance in many livestock species. The timing and duration of maternal nutritional restriction appears to influence the capillary vascularity, angiogenic profile and vascular function of the placenta in cattle and sheep. In environments where fetal growth and/or fetal organogenesis are compromised, potential therapeutics may augment placental nutrient transport capacity and improve offspring performance. Supplementation of specific nutrients, including protein, as well as hormone supplements, such as indolamines, during times of nutrient restriction may assist placental function. Current use of Doppler ultrasonography has allowed for repeated measurements of uterine and umbilical blood flow including assessment of uteroplacental hemodynamics in cattle, sheep and swine. Moreover, these variables can be monitored in conjugation with placental capacity and fetal growth at specific time points of gestation. Elucidating the consequences of inadequate maternal intake on the continual plasticity of placental function will allow us to determine the proper timing and duration for intervention.
NASA Technical Reports Server (NTRS)
Mundt, C.
1999-01-01
Sensors 2000! is developing pill-shaped biotelemeters for measuring physiological parameters during space flight life sciences experiments using rodents aboard the ISS Gravitational Biology Facility, with the additional capability for monitoring the health of astronauts in the Human Research Facility. The first "pill transmitter" is capable of measuring pressure and temperature for up to 10 months. The NASA objective is to utilize these devices. The pill-transmitters can also be used by non-NASA users for medical applications. One application is fetal surgery. The 44pill" is small enough to be endoscopically placed into the womb through a tube used during surgeries to correct fetal defects before birth. After surgery, the pill-transmitter will continue to monitor body temperature, pressure and other vital signs in the womb, radioing results to physicians. It will help them to detect preterm-labor, a serious problem after fetal surgery. The pill is about one-third-of-an-inch across and one-and-one-third-inches long. Future pill-versions will include pH, heartrate, and ECG. A pH-pill prototype is currently being tested. Sensors 2000! has also designed and built a 2-channel biotelemetry receiver and has developed data acquisition software to display and record the measured physiological parameters. A DSP-base hand-held receiver (trisponder) is currently under development.
Martinek, Radek; Nedoma, Jan; Fajkus, Marcel; Kahankova, Radana; Konecny, Jaromir; Janku, Petr; Kepak, Stanislav; Bilik, Petr; Nazeran, Homer
2017-04-18
This paper focuses on the design, realization, and verification of a novel phonocardiographic- based fiber-optic sensor and adaptive signal processing system for noninvasive continuous fetal heart rate (fHR) monitoring. Our proposed system utilizes two Mach-Zehnder interferometeric sensors. Based on the analysis of real measurement data, we developed a simplified dynamic model for the generation and distribution of heart sounds throughout the human body. Building on this signal model, we then designed, implemented, and verified our adaptive signal processing system by implementing two stochastic gradient-based algorithms: the Least Mean Square Algorithm (LMS), and the Normalized Least Mean Square (NLMS) Algorithm. With this system we were able to extract the fHR information from high quality fetal phonocardiograms (fPCGs), filtered from abdominal maternal phonocardiograms (mPCGs) by performing fPCG signal peak detection. Common signal processing methods such as linear filtering, signal subtraction, and others could not be used for this purpose as fPCG and mPCG signals share overlapping frequency spectra. The performance of the adaptive system was evaluated by using both qualitative (gynecological studies) and quantitative measures such as: Signal-to-Noise Ratio-SNR, Root Mean Square Error-RMSE, Sensitivity-S+, and Positive Predictive Value-PPV.
Martinek, Radek; Nedoma, Jan; Fajkus, Marcel; Kahankova, Radana; Konecny, Jaromir; Janku, Petr; Kepak, Stanislav; Bilik, Petr; Nazeran, Homer
2017-01-01
This paper focuses on the design, realization, and verification of a novel phonocardiographic- based fiber-optic sensor and adaptive signal processing system for noninvasive continuous fetal heart rate (fHR) monitoring. Our proposed system utilizes two Mach-Zehnder interferometeric sensors. Based on the analysis of real measurement data, we developed a simplified dynamic model for the generation and distribution of heart sounds throughout the human body. Building on this signal model, we then designed, implemented, and verified our adaptive signal processing system by implementing two stochastic gradient-based algorithms: the Least Mean Square Algorithm (LMS), and the Normalized Least Mean Square (NLMS) Algorithm. With this system we were able to extract the fHR information from high quality fetal phonocardiograms (fPCGs), filtered from abdominal maternal phonocardiograms (mPCGs) by performing fPCG signal peak detection. Common signal processing methods such as linear filtering, signal subtraction, and others could not be used for this purpose as fPCG and mPCG signals share overlapping frequency spectra. The performance of the adaptive system was evaluated by using both qualitative (gynecological studies) and quantitative measures such as: Signal-to-Noise Ratio—SNR, Root Mean Square Error—RMSE, Sensitivity—S+, and Positive Predictive Value—PPV. PMID:28420215
Influence of gestational age and time of day in baseline and heart rate variation of fetuses.
Li, Guangfei; Zhang, Song; Yang, Lin; Li, Shufang; Wang, Yan; Hao, Dongmei; Yang, Yimin; Li, Xuwen; Zhang, Lei; Xu, Mingzhou
2016-04-29
Fetal electrocardiography (FECG) places electrodes on the maternal abdomen to convert the fetal electrocardiosignals into fetal heart rate (FHR), improving the accuracy and comfort of pregnant woman. At the same time, FECG simplifies the procedure of long term monitoring in the perinatal period. Investigating the influence of gestational age and time of day on FHR features to distinguish between non-stress test (NST) normal fetuses and NST suspicious fetuses. A novel method of FHR baseline estimation was presented; then baseline value and fetal heart rate variation (FHRV) were analyzed in the time domain using FHR signals recorded from 52 fetuses. Baseline values in 1:00, 2:00, 4:00, 5:00 and heart rate variation (HRV) distribution showed a significant difference (p< 0.05) between NST normal fetuses and NST suspicious fetuses. The results suggest that NST normal and suspicious fetuses had same outcome and different FHR features. Accurately distinguishing normal fetuses and suspicious fetuses is important for lowering the false positive rate and reducing unnecessary clinical intervention.
Real time observation of mouse fetal skeleton using a high resolution X-ray synchrotron
Chang, Dong Woo; Kim, Bora; Shin, Jae Hoon; Yun, Young Min; Je, Jung Ho; Hwu, Yeu kuang; Yoon, Jung Hee
2011-01-01
The X-ray synchrotron is quite different from conventional radiation sources. This technique may expand the capabilities of conventional radiology and be applied in novel manners for special cases. To evaluate the usefulness of X-ray synchrotron radiation systems for real time observations, mouse fetal skeleton development was monitored with a high resolution X-ray synchrotron. A non-monochromatized X-ray synchrotron (white beam, 5C1 beamline) was employed to observe the skeleton of mice under anesthesia at embryonic day (E)12, E14, E15, and E18. At the same time, conventional radiography and mammography were used to compare with X-ray synchrotron. After synchrotron radiation, each mouse was sacrificed and stained with Alizarin red S and Alcian blue to observe bony structures. Synchrotron radiation enabled us to view the mouse fetal skeleton beginning at gestation. Synchrotron radiation systems facilitate real time observations of the fetal skeleton with greater accuracy and magnification compared to mammography and conventional radiography. Our results show that X-ray synchrotron systems can be used to observe the fine structures of internal organs at high magnification. PMID:21586868
Growth curves for twins in Slovenia.
Bricelj, Katja; Blickstein, Isaac; Bržan-Šimenc, Gabrijela; Janša, Vid; Lučovnik, Miha; Verdenik, Ivan; Trojner-Bregar, Andreja; Tul, Nataša
2017-02-01
Abnormalities of fetal growth are more common in twins. We introduce the growth curves for monitoring fetal growth in twin pregnancies in Slovenia. Slovenian National Perinatal Information System for the period between 2002 and 2010 was used to calculate birth weight percentiles for all live born twins for each week from 22nd to 40th week. The calculated percentiles of birth weight for all live-born twins in Slovenia served as the basis for drawing 'growth' curves. The calculated growth curves for twins will help accurately diagnose small or large twin fetuses for their gestational age in the native central European population.
Perinatal Care of Infants with Congenital Birth Defects.
Sewell, Elizabeth K; Keene, Sarah
2018-06-01
Prenatal diagnosis has changed perinatal medicine dramatically, allowing for additional fetal monitoring, referral and counseling, delivery planning, the option of fetal intervention, and targeted postnatal management. Teams participating in the delivery room care of infants with known anomalies should be knowledgeable about specific needs and expectations but also ready for unexpected complications. A small number of neonates will need rapid access to postnatal interventions, such as surgery, but most can be stabilized with appropriate neonatal care. These targeted perinatal interventions have been shown to improve outcome in selected diagnoses. Copyright © 2018 Elsevier Inc. All rights reserved.
Doppler ultrasound monitoring technology.
Docker, M F
1993-03-01
Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.
Intrauterine Growth Restriction (IUGR)
... IUGR, such as: fetal monitoring to track the baby's heart rate and movements screenings for infections amniocentesis to help find the cause of IUGR (and sometimes to help determine lung maturity and whether the baby is likely to be able to breathe on ...
The neural and vascular effects of killed Su-Streptococcus pyogenes (OK-432) in preterm fetal sheep
Cowie, R. V.; Stone, P. R.; Barrett, R.; Naylor, A. S.; Blood, A. B.; Gunn, A. J.
2010-01-01
Fetal exposure to inflammatory mediators is associated with a greater risk of brain injury and may cause endothelial dysfunction; however, nearly all the evidence is derived from gram-negative bacteria. Intrapleural injections of OK-432, a killed Su-strain of Streptococcus pyogenes, has been used to treat fetal chylothorax. In this study, we evaluated the neural and cardiovascular effects of OK-432 in preterm fetal sheep (104 ± 1 days, term 147 days). OK-432 (0.1 mg, n = 6) or saline vehicle (n = 7) was infused in the fetal pleura, and fetuses were monitored for 7 days. Blood samples were taken routinely for plasma nitrite measurement. Fetal brains were taken for histological assessment at the end of the experiment. Between 3 and 7 h postinjection, OK-432 administration was associated with transient suppression of fetal body and breathing movements and electtroencephalogram activity (P < 0.05), increased carotid and femoral vascular resistance (P < 0.05), but no change in blood pressure. Brain activity and behavior then returned to normal except in one fetus that developed seizures. OK-432 fetuses showed progressive, sustained vasodilatation (P < 0.05), with lower blood pressure after 4 days (P < 0.05), but normal heart rate. There were no changes in plasma nitrite levels. Histological studies showed bilateral infarction in the dorsal limb of the hippocampus of the fetus that developed seizures, but no injury in other fetuses. We conclude that a single low-dose injection of OK-432 can be associated with risk of focal cerebral injury in the preterm fetus and chronic central and peripheral vasodilatation that does not appear to be mediated by nitric oxide. PMID:20484698
The neural and vascular effects of killed Su-Streptococcus pyogenes (OK-432) in preterm fetal sheep.
Bennet, L; Cowie, R V; Stone, P R; Barrett, R; Naylor, A S; Blood, A B; Gunn, A J
2010-08-01
Fetal exposure to inflammatory mediators is associated with a greater risk of brain injury and may cause endothelial dysfunction; however, nearly all the evidence is derived from gram-negative bacteria. Intrapleural injections of OK-432, a killed Su-strain of Streptococcus pyogenes, has been used to treat fetal chylothorax. In this study, we evaluated the neural and cardiovascular effects of OK-432 in preterm fetal sheep (104 +/- 1 days, term 147 days). OK-432 (0.1 mg, n = 6) or saline vehicle (n = 7) was infused in the fetal pleura, and fetuses were monitored for 7 days. Blood samples were taken routinely for plasma nitrite measurement. Fetal brains were taken for histological assessment at the end of the experiment. Between 3 and 7 h postinjection, OK-432 administration was associated with transient suppression of fetal body and breathing movements and electtroencephalogram activity (P < 0.05), increased carotid and femoral vascular resistance (P < 0.05), but no change in blood pressure. Brain activity and behavior then returned to normal except in one fetus that developed seizures. OK-432 fetuses showed progressive, sustained vasodilatation (P < 0.05), with lower blood pressure after 4 days (P < 0.05), but normal heart rate. There were no changes in plasma nitrite levels. Histological studies showed bilateral infarction in the dorsal limb of the hippocampus of the fetus that developed seizures, but no injury in other fetuses. We conclude that a single low-dose injection of OK-432 can be associated with risk of focal cerebral injury in the preterm fetus and chronic central and peripheral vasodilatation that does not appear to be mediated by nitric oxide.
Fetal source extraction from magnetocardiographic recordings by dependent component analysis
NASA Astrophysics Data System (ADS)
de Araujo, Draulio B.; Kardec Barros, Allan; Estombelo-Montesco, Carlos; Zhao, Hui; Roque da Silva Filho, A. C.; Baffa, Oswaldo; Wakai, Ronald; Ohnishi, Noboru
2005-10-01
Fetal magnetocardiography (fMCG) has been extensively reported in the literature as a non-invasive, prenatal technique that can be used to monitor various functions of the fetal heart. However, fMCG signals often have low signal-to-noise ratio (SNR) and are contaminated by strong interference from the mother's magnetocardiogram signal. A promising, efficient tool for extracting signals, even under low SNR conditions, is blind source separation (BSS), or independent component analysis (ICA). Herein we propose an algorithm based on a variation of ICA, where the signal of interest is extracted using a time delay obtained from an autocorrelation analysis. We model the system using autoregression, and identify the signal component of interest from the poles of the autocorrelation function. We show that the method is effective in removing the maternal signal, and is computationally efficient. We also compare our results to more established ICA methods, such as FastICA.
Survey of Cooling Options for Application in a Low-TC Squid System for Fetal Magnetocardiography
NASA Astrophysics Data System (ADS)
Rijpma, A. P.; Uzunbajakau, S.; ter Brake, H. J. M.; Peters, M. J.; Rogalla, H.
2004-06-01
As part of the development of a low-Tc SQUID-based magnetometer system for measuring fetal heart activity, the means of cooling is evaluated. To lower the threshold for the clinical application of this fetal heart monitor, it should be simple to operate. It is, therefore, deemed necessary to replace the liquid helium by a closed-cycle refrigerator. In this paper, the requirements with respect to the cryogenic system are defined. These include operating temperature (4 K), temperature stability (<0.2 K), cooling power (>0.1 W) and requirements on magnetic and mechanical interference. The paper also reviews the most relevant options for the realization of the cryogenic system. After comparison, we selected a 4-K mechanical cooler. To reduce the interference, it is placed at several meters from the magnetometer. The cooling power is to be transferred by circulation of helium.
de Haas, Masja; Thurik, Florentine F; van der Ploeg, Catharina P B; Veldhuisen, Barbera; Hirschberg, Hoang; Soussan, Aicha Ait; Woortmeijer, Heleen; Abbink, Frithjofna; Page-Christiaens, Godelieve C M L; Scheffer, Peter G; Ellen van der Schoot, C
2016-11-07
To determine the accuracy of non-invasive fetal testing for the RHD gene in week 27 of pregnancy as part of an antenatal screening programme to restrict anti-D immunoglobulin use to women carrying a child positive for RHD DESIGN: Prospectively monitoring of fetal RHD testing accuracy compared with serological cord blood typing on introduction of the test. Fetal RHD testing was performed with a duplex real time quantitative polymerase chain reaction, with cell-free fetal DNA isolated from 1 mL of maternal plasma The study period was between 4 July 2011 and 7 October 2012. The proportion of women participating in screening was determined. Nationwide screening programme, the Netherlands. Tests are performed in a centralised setting. 25 789 RhD negative pregnant women. Sensitivity, specificity, false negative rate, and false positive rate of fetal RHD testing compared with serological cord blood typing; proportion of technical failures; and compliance to the screening programme. A fetal RHD test result and serological cord blood result were available for 25 789 pregnancies. Sensitivity for detection of fetal RHD was 99.94% (95% confidence interval 99.89% to 99.97%) and specificity was 97.74% (97.43% to 98.02%). Nine false negative results for fetal RHD testing were registered (0.03%, 95% confidence interval 0.01% to 0.06%). In two cases these were due to technical failures. False positive fetal RHD testing results were registered for 225 samples (0.87%, 0.76% to 0.99%). Weak RhD expression was shown in 22 of these cases, justifying anti-D immunoglobulin use. The negative and positive predictive values were 99.91% (95% confidence interval 99.82% to 99.95%) and 98.60% (98.40% to 98.77%), respectively. More than 98% of the women participated in the screening programme. Fetal RHD testing in week 27 of pregnancy as part of a national antenatal screening programme is highly reliable and can be used to target both antenatal and postnatal anti-D immunoglobulin use. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Vitner, D; Paltieli, Y; Haberman, S; Gonen, R; Ville, Y; Nizard, J
2015-11-01
To assess the relationship between fetal head position and head station during labor, as measured using an ultrasound-based system, and the occurrence of occiput posterior (OP) position at delivery. This was an international prospective observational study including women who delivered between January 2009 and September 2013 in four centers: one in Brooklyn, NY, USA; one in Haifa, Israel; and two in Paris, France. We used an ultrasound-based system (LaborPro) to monitor fetal head station and position non-invasively throughout labor. We collected data on demographics, labor parameters and outcome. A total of 595 women were included. In 563 (94.6%) women, fetal head position at delivery was occiput anterior (OA), in 31 (5.2%) it was OP and in one (0.2%) it was occiput transverse. In 89% of pregnancies with intrapartum OP when fetal head station was above -2, the head position turned to OA at delivery; the equivalent figures were 74% and 63% OA at delivery when intrapartum OP was diagnosed at head stations of -2 to < 0, and 0 and below, respectively. Cesarean delivery was performed in 35% of pregnancies with fetal head in OP position at delivery, as opposed to 10% of those with non-OP position at delivery. On retrospective analysis, all deliveries in OP were already in OP at station -2 and below. In this first assessment of fetal head position at delivery according to fetal head position at various station levels, our data show that 100% of OP positions at delivery were already in OP position at station -2 and below. We did not observe rotation from a non-OP to an OP position from station -2 and below. Nearly two-thirds of fetuses in OP at station 0 and below will rotate to an OA position for delivery. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.
Fetal movement detection: comparison of the Toitu actograph with ultrasound from 20 weeks gestation.
DiPietro, J A; Costigan, K A; Pressman, E K
1999-01-01
This study evaluates the validity of Doppler-detected fetal movement by a commercially available monitor and investigates whether characteristics of maternal body habitus and the intrauterine environment affect its performance. Fetal movement was evaluated in normal pregnancies using both ultrasound visualization and a fetal actocardiograph (Toitu MT320; Tofa Medical Inc., Malvern, PA). Data were collected for 32 min on 34 fetuses stratified by gestational age (20-25 weeks; 28-32 weeks; 35-39 weeks). Fetal and maternal characteristics were recorded. Comparisons between ultrasound-detected trunk and limb movements and actograph records were conducted based both on 10-s time intervals and on detection of individual movements. Time-based comparisons indicated agreement between ultrasound and actograph 94.7% of the time; this association rose to 98% when movements of less than 1 s duration were excluded. Individual movements observed on ultrasound were detected by the actograph 91% of the time, and 97% of the time when brief, isolated movements were excluded. The overall kappa value for agreement was 0.88. The actograph was reliable in detecting periods of quiescence as well as activity. These findings did not vary by gestational age. The number of movements detected by the actograph, but not the single-transducer ultrasound, significantly increased over gestation. Maternal age, parity, weight, height, or body mass index were not consistently associated with actograph validity. Characteristics of the uterine environment, including placenta location, fetal presentation, and amniotic fluid volume also did not affect results. The Toitu actograph accurately detects fetal movement and quiescence from as early as 20 weeks gestation and has utility in both clinical and research settings. Actographs are most useful for providing objective and quantifiable measures of fetal activity level, including number and duration of movements, while visualization through ultrasound is necessary for studies of movement quality, source, or mechanics.
Sousa, Francisco C A; Pessoa, Gerson T; Moura, Laecio S; Rodrigues, Renan P S; Diniz, Anaemilia N; Souza, André B; Silva, Elzivânia G; Sanches, Marina P; Silva-Filho, Osmar F; Guerra, Porfirio C; Sousa, João M; Neves, Willams C; Alves, Flávio R
2016-11-01
The use of ultrasound for pregnancy monitoring is critical for the evaluation of hemodynamic parameters essential to fetal viability. In the present study, using B-mode and Doppler ultrasound, we characterized the placenta, subplacenta, maternal, and fetal vessels during normal gestation of healthy agoutis raised in captivity. In total, 30 agoutis were obtained from the Center for the Study and Preservation of Wild Animals, Center of Agricultural Sciences, Federal University of Piauí (Núcleo de Estudos e Preservação de Animais Silvestres-NEPAS, Centro de Ciências Agrárias-CCA, Universidade Federal do Piauí-UFPI). These animals were subjected to B-mode and Doppler ultrasound examinations to evaluate their maternal and fetal hemodynamic profiles. The placenta was located in the mesometrial region and had a discoid, ellipsoid, or globular aspect. With spectral Doppler, characteristic systolic and diastolic flow was observed in the umbilical artery. This flow increased during pregnancy. A cross-sectional view revealed a goblet-shaped placenta. The uteroplacental blood flow was characterized by a marked increase in systolic peak velocity during pregnancy, the presence of a rapid deceleration ramp, and a relatively high diastolic speed. The fetal aortic vascular flow was predominantly systolic and diastolic. The caudal vena cava blood flow was characterized by a systolic peak followed by a decreased diastolic wave throughout pregnancy. In the present study, we characterized the morphologic and hemodynamic interactions of the placenta/subplacenta with maternal and fetal vessels in agoutis at 30, 45, 60, 75, and 90 days gestation using B-mode and Doppler ultrasound. We determined the approximation and separation of the blood flow values of the umbilical artery, subplacental flow, uteroplacental artery, fetal aorta, and fetal vena cava. We believe these values may contribute to an understanding of the gestational biology and aid delivery prediction in this species. Copyright © 2016 Elsevier Inc. All rights reserved.
Reproductive health indicators and fetal medicine - many things will change.
Olsen, Jørn; Pedersen, Lars Henning
2016-06-01
Reproductive epidemiologists study disease outcomes over three time periods: (i) from conception, or before, to birth, (ii) from birth to death and (iii) from death and into the next generations. They have traditionally been short of data from the time of conception to birth, and we use data at birth to estimate fetal growth or the incidence of congenital malformations. Although we are interested in incidence data for defects that start early in gestation, we have to use prevalence data at birth. Cumulative incidence will only be similar to prevalence at birth given no competing risks - or no fetal death after the onset of the lesion. Routinely use of ultrasound methods in fetal medicine will change our monitoring of structural birth defects. We may now be able to link exposures to events with the right time sequence, for example on fetal growth deviations and get better data on fetal deaths also for twins and triplets. The scientific challenges will mainly come from induced abortions following ultrasound examinations. Ultrasound data from the time of pregnancy will be of crucial importance for studies on fetal programming or "developmental origins of health and disease" (DOHaD). In humans, babies that are small at birth have an increased risk of, eg, cardiovascular disease, as shown by DJ Barker in the 1980s (1), but this association is probably not a direct consequence of the low birth weight but rather caused by external or internal exposures during fetal life. DOHaD studies that use outcomes at birth, including weight, as exposures or intermediates may be biased. One notorious example is the apparent protective effect of smoking on the mortality of children with a low birth weight (2). This bias, partly related to collider stratification bias, is potentially less important in studies using direct ultrasound assessments. The risk of reverse causation may also be reduced in longitudinal studies based on ultrasound data. Fetal ultrasound examinations are also done to detect fetal structural abnormalities in order to start early treatment or terminate an effected pregnancy if that is permitted and requested by the parents. This change in timing and validity of determining congenital abnormalities (CA) will have substantial consequences for our monitoring of CA over time. Most of the existing monitoring systems are based on measuring prevalence of CA at time of birth, often allowing for a time period of detection from months to years since some of the CA are not detected at birth. They may be detected by ultrasound during gestation, but even for CA detectable in gestational weeks 20-24 and at birth, the sensitivity and specificity of times of diagnosing may differ so much that the measures are not comparable. Furthermore, the time from ultrasound to birth is sometimes interrupted by late fetal deaths and some of these deaths may be induced on indication. In any case, it will be difficult to reestablish long-term monitoring trends by applying birth correcting factors that will differ by the type of CA. We probably have to accept that long-term time trends need years to be reestablished and will have to be based on updated diagnostic facilities that will change over time. It may be difficult to spot increases in the incidence of CA in the future. An increase could be real or related to better diagnostic facilities operating in the time period from conception to birth. Fetal medicine will sometimes make it possible to study causes and events in the proper time sequence, which is important since a cause has to precede an event as the only sine qua non causal criteria. Measurements of recurrence "risks" of CA in families have always been complicated. It is well known that several CA have a tendency to be repeated in a subsequent pregnancy, most likely related to genetic factors or other time stable environmental exposures. Better diagnostic facilities with an option for an induced abortion may encourage high-risk parents to try to become pregnant and this may affect estimates of recurrence risk. In any case, calculating recurrence risk for newborns following siblings with the CA in question will probably no longer work (maybe it never worked) since the desire to reach a given family size depends on many factors, including the perceived risk of a CA. Access to prenatal diagnostic data may therefore well produce data closer to recurrence risk than data recorded at the time of birth. Pediatrics and Perinatal Epidemiology recently published a series of papers initiated by Olga Basso (3, 4) addressing in part the problem of moving from time scale one (starting at conception) to time scale two (starting at birth). Part of the addressed problems relate to a lack of options for starting observations on causal factors at the onset of exposure or, at best, before exposure. If that exposure happens early in fetal life, outcomes will be complicated by fetal deaths that probably end observation for ≥30% of subjects. That equals mortality rates we see for ≥95-year-olds or equals a cumulative death risk seen for newborns from birth to ≥65 years of age. If the exposure of interest is related to fetal death that opens up for strong collider stratification bias and selection when we condition on survival in our analyses for observations at the beginning of the second time scale (5). A negative association on that time scale need not reflect "prevention" in any sense other than suicides early in life will prevent later cancer deaths. It is difficult to imagine a counterfactual comparison to an exposed had he/she not been exposed and had survived fetal life. Those who were susceptible did not all survive. If we study fetal programming of adult diseases, we have to "condition on birth" in our studies, but we should be aware of the selection bias that follows. Fetal medicine will in many ways produce better data or data we never have had before, but it will change the conditions in many aspects of reproductive epidemiology. The main advantage in analytical epidemiology is to get the time sequence right from exposure to outcome to avoid the problem of reverse causation and to do proper mediation analyses. Conflict of interest The authors declare no conflicts of interest.
Ferro, Marta; Macher, Hada C; Noguerol, Pilar; Jimenez-Arriscado, Pilar; Molinero, Patrocinio; Guerrero, Juan M; Rubio, Amalia
2016-01-01
Fetal and Neonatal alloimmune thrombocytopenia (FNAIT) is a condition which could occur when pregnant women develop an alloimmunization against paternally inherited antigens of the fetal platelets. Approximately 80 % of FNAIT cases are caused by anti-HPA-1a, about 15 % by anti-HPA-5b and 5 % by other HPA antibodies. Only 2 % of the total population is HPA-1a negative (HPA-1b1b). The HPA-1a allele differs by one single nucleotide from HPA-1b allele, yet it represents around 27 % of total severe thrombocytopenias. HPA-1 was studied in serum cDNA from 12 volunteer pregnant women to determine their HPA-1 genotype by HRM (high resolution melting) PCR. When an homozygous HPA-1 gene was detected in a mother, a COLD HRM was performed to determine whether or not the fetal genotype differs from the mother's.The differences in the melting curve shapes allow us to accurately distinguish the three pregnants genotypes. The fetal heterozygous genotype of homozygous pregnant women was correctly detected by COLD PCR HRM in maternal serum. HPA-1 genotyping by HRM may be a useful aproach for genotyping all pregnant women in inexpensively. Moreover, when HPA-1 homozygosis was detected in a pregnant woman, fetal heterozygosis may be diagnosed by COLD HRM to select pregnancies for preventive monitoring.
Ohara, Noriyuki; Tsujino, Taro; Maruo, Takeshi
2004-11-01
To review the literature on the roles of thyroid hormone in trophoblast function, early pregnancy maintenance, and fetal neurodevelopment. MEDLINE was searched for English-language papers published from 1971 to 2003, using the key words "brain," "hypothyroidism," "placenta," "pregnancy," "threatened abortion," "thyroid hormone," "thyroid hormone receptor," "thyroid hormone replacement therapy," "thyroid hormone-responsive gene," and "trophoblast." Transplacental transfer of thyroid hormone occurs before the onset of fetal thyroid hormone secretion. Thyroid hormone receptors and iodothyronine deiodinases are present in the placenta and the fetal central nervous system early in pregnancy, and thyroid hormone plays a crucial role both in trophoblast function and fetal neurodevelopment. Maternal hypothyroxinemia is associated with a high rate of spontaneous abortion and long-term neuropsychological deficits in children born of hypothyroid mothers. Maternal iodine deficiency also causes a wide spectrum of neuropsychological disorders in children, ranging from subclinical deficits in cognitive motor and auditory functions to hypothyroid-induced cognitive impairment in infants. However, these conditions are preventable when iodine supplementation is initiated before the second trimester. Although thyroid hormone replacement therapy is effective for reducing the adverse effects complicated by maternal hypothyroidism, the appropriate dose of thyroid hormone is mandatory in protecting the early stage of pregnancy. Close monitoring of maternal thyroid hormone status and ensuring adequate maternal thyroid hormone levels in early pregnancy are of great importance to prevent miscarriage and neuropsychological deficits in infants.
Olutoye, Oluyinka O; Johnson, Mark P; Coleman, Beverly G; Crombleholme, Timothy M; Adzick, N Scott; Flake, Alan W
2004-01-01
To identify factors predictive of fetal demise in fetuses with sacrococcygeal teratoma (SCT). The recent management of monochorionic twins discordant for a large SCT and a singleton with a large SCT was reviewed. Serial fetal echocardiography and ultrasonography with Doppler flow measurements documented rapid growth of the SCT in both cases with a relatively modest increase in combined cardiac output. No placentomegaly or hydrops was observed at any time. In both fetuses with SCT, evolution of abnormal umbilical artery waveforms was observed with the ultimate development of reversed end-diastolic umbilical arterial flow that was followed by sudden fetal demise. Death in these 2 fetuses with large SCTs in the absence of placentomegaly/hydrops or hemodynamic changes suggestive of evolving high-output failure suggests a previously unrecognized mechanism of death in fetuses with large rapidly growing SCTs. In these cases, fetal demise may only be heralded by abnormal umbilical artery waveforms that progress to the premorbid observation of reversed diastolic umbilical artery blood flow. Umbilical artery waveform analysis should be closely monitored with other hemodynamic parameters in fetuses with large SCTs. In such fetuses, depending on the gestational age, abnormalities in umbilical artery waveform should be considered indications for early delivery or in utero intervention to prevent fetal demise. Copyright 2004 S. Karger AG, Basel
Olutoye, Oluyinka O; Johnson, Mark P; Coleman, Beverly G; Crombleholme, Timothy M; Adzick, N Scott; Flake, Alan W
2003-01-01
To identify factors predictive of fetal demise in fetuses with sacrococcygeal teratoma (SCT). The recent management of monochorionic twins discordant for a large SCT and a singleton with a large SCT were reviewed. Serial fetal echocardiography and ultrasonography with Doppler flow measurements documented rapid growth of the SCT in both cases with a relatively modest increase in combined cardiac output. No placentomegaly or hydrops was observed at any time. In both fetuses with SCT, evolution of abnormal umbilical artery waveforms was observed with the ultimate development of reversed end-diastolic umbilical arterial flow that was followed by sudden fetal demise. Death in these 2 fetuses with large SCTs in the absence of placentomegaly/hydrops or hemodynamic changes suggestive of evolving high-output failure suggests a previously unrecognized mechanism of death in fetuses with large rapidly growing SCTs. In these cases, fetal demise may only be heralded by abnormal umbilical artery waveforms that progress to the premorbid observation of reversed diastolic umbilical artery blood flow. Umbilical artery waveform analysis should be closely monitored with other hemodynamic parameters in fetuses with large SCTs. In such fetuses, depending on the gestational age, abnormalities in umbilical artery waveform should be considered indications for early delivery or in utero intervention to prevent fetal demise. Copyright 2003 S. Karger AG, Basel
Reinhard, J.; Hayes-Gill, B. R.; Schiermeier, S.; Hatzmann, W.; Heinrich, T. M.; Hüsken-Janßen, H.; Herrmann, E.; Louwen, F.
2012-01-01
Objective: To investigate the functional adaptive process of the fetal autonomic nervous system during hypnosis from the 20th week of gestation till term. Are there changes in the power spectrum analysis of fetal heart rate when the mother is having a clinical hypnosis or control period? Study Design: Fourty-nine FHR recordings were analysed. Included recordings were from singletons and abdominal fetal ECG-monitored pregnancies. All women were randomised to receive clinical hypnosis followed by a period with no intervention or vice versa. Statistical analyses were performed with the Wilcoxon signed ranks and Spearman rho correlation tests. Results: There was a significant difference found between fetal heart rate at baseline (144.3 ± 6.0) and hypnosis (142.1 ± 6.4). A difference was also detected between the standard deviation of the heart rate between baseline (6.7 ± 1.9) and hypnosis (6.8 ± 3.5). LFnu was smaller during baseline (80.2 ± 5.3) than during hypnosis (82.1 ± 5.7), whereas HFnu was significantly larger (19.8 ± 5.3 vs. 17.9 ± 5.7). There was no correlation between the gestation age and the change in LFnu, HFnu or ratio LF/HF due to the hypnosis intervention. Conclusion: The functional adaptive process of the fetal autonomic system during hypnosis is reflected by a sympathovagal shift towards increased sympathetic modulation. PMID:25284838
Size-based molecular diagnostics using plasma DNA for noninvasive prenatal testing.
Yu, Stephanie C Y; Chan, K C Allen; Zheng, Yama W L; Jiang, Peiyong; Liao, Gary J W; Sun, Hao; Akolekar, Ranjit; Leung, Tak Y; Go, Attie T J I; van Vugt, John M G; Minekawa, Ryoko; Oudejans, Cees B M; Nicolaides, Kypros H; Chiu, Rossa W K; Lo, Y M Dennis
2014-06-10
Noninvasive prenatal testing using fetal DNA in maternal plasma is an actively researched area. The current generation of tests using massively parallel sequencing is based on counting plasma DNA sequences originating from different genomic regions. In this study, we explored a different approach that is based on the use of DNA fragment size as a diagnostic parameter. This approach is dependent on the fact that circulating fetal DNA molecules are generally shorter than the corresponding maternal DNA molecules. First, we performed plasma DNA size analysis using paired-end massively parallel sequencing and microchip-based capillary electrophoresis. We demonstrated that the fetal DNA fraction in maternal plasma could be deduced from the overall size distribution of maternal plasma DNA. The fetal DNA fraction is a critical parameter affecting the accuracy of noninvasive prenatal testing using maternal plasma DNA. Second, we showed that fetal chromosomal aneuploidy could be detected by observing an aberrant proportion of short fragments from an aneuploid chromosome in the paired-end sequencing data. Using this approach, we detected fetal trisomy 21 and trisomy 18 with 100% sensitivity (T21: 36/36; T18: 27/27) and 100% specificity (non-T21: 88/88; non-T18: 97/97). For trisomy 13, the sensitivity and specificity were 95.2% (20/21) and 99% (102/103), respectively. For monosomy X, the sensitivity and specificity were both 100% (10/10 and 8/8). Thus, this study establishes the principle of size-based molecular diagnostics using plasma DNA. This approach has potential applications beyond noninvasive prenatal testing to areas such as oncology and transplantation monitoring.
Size-based molecular diagnostics using plasma DNA for noninvasive prenatal testing
Yu, Stephanie C. Y.; Chan, K. C. Allen; Zheng, Yama W. L.; Jiang, Peiyong; Liao, Gary J. W.; Sun, Hao; Akolekar, Ranjit; Leung, Tak Y.; Go, Attie T. J. I.; van Vugt, John M. G.; Minekawa, Ryoko; Oudejans, Cees B. M.; Nicolaides, Kypros H.; Chiu, Rossa W. K.; Lo, Y. M. Dennis
2014-01-01
Noninvasive prenatal testing using fetal DNA in maternal plasma is an actively researched area. The current generation of tests using massively parallel sequencing is based on counting plasma DNA sequences originating from different genomic regions. In this study, we explored a different approach that is based on the use of DNA fragment size as a diagnostic parameter. This approach is dependent on the fact that circulating fetal DNA molecules are generally shorter than the corresponding maternal DNA molecules. First, we performed plasma DNA size analysis using paired-end massively parallel sequencing and microchip-based capillary electrophoresis. We demonstrated that the fetal DNA fraction in maternal plasma could be deduced from the overall size distribution of maternal plasma DNA. The fetal DNA fraction is a critical parameter affecting the accuracy of noninvasive prenatal testing using maternal plasma DNA. Second, we showed that fetal chromosomal aneuploidy could be detected by observing an aberrant proportion of short fragments from an aneuploid chromosome in the paired-end sequencing data. Using this approach, we detected fetal trisomy 21 and trisomy 18 with 100% sensitivity (T21: 36/36; T18: 27/27) and 100% specificity (non-T21: 88/88; non-T18: 97/97). For trisomy 13, the sensitivity and specificity were 95.2% (20/21) and 99% (102/103), respectively. For monosomy X, the sensitivity and specificity were both 100% (10/10 and 8/8). Thus, this study establishes the principle of size-based molecular diagnostics using plasma DNA. This approach has potential applications beyond noninvasive prenatal testing to areas such as oncology and transplantation monitoring. PMID:24843150
Zornoza-Moreno, Matilde; Fuentes-Hernández, Silvia; Prieto-Sánchez, María T; Blanco, José E; Pagán, Ana; Rol, María-Ángeles; Parrilla, Juan J; Madrid, Juan A; Sánchez-Solis, Manuel; Larqué, Elvira
2013-09-01
To analyse the circadian rhythm maturation of temperature, activity and sleep during the first year of life in offspring of diabetic mothers (ODM) and its relationship with obesity markers. A prospective analysis of the children of 63 pregnant women (23 controls, 21 gestational diabetes mellitus (GDM) controlled with diet and 19 GDM with insulin). Fetal abdominal circumference was evaluated ecographically during gestation. Skin temperature and rest-activity rhythms were monitored for 3 consecutive days in children at 15 days and 1, 3 and 6 months. Anthropometrical parameters of the children were evaluated during the first year of life. Children from the GDM groups tended to higher fetal abdominal circumference z-score than controls at the beginning of the last trimester (p = 0.077) and at delivery (p = 0.078). Mean skin temperature or activity was not different among the groups. The I < O sleep index pointed to increasing concordance with parental sleeping at 3 and 6 months but no significant GDM-dependent differences. However, some of the parameters that define temperature maturation and also the circadian function index from the temperature-activity variable were significantly lower at 6 months in the GDM + insulin group. Fetal abdominal circumference z-score, as a predictor of fetal adiposity, correlated negatively with parameters related to circadian rhythm maturation as the circadian/ultradian rhythm (P1 /Pult ratio). Fetal adiposity correlated with a worse circadian rhythm regulation in ODM. In addition, ODM insulin-treated showed a disturbed pattern of the circadian function index of temperature activity at 6 months of age. Copyright © 2013 John Wiley & Sons, Ltd.
Hardware Prototyping of Neural Network based Fetal Electrocardiogram Extraction
NASA Astrophysics Data System (ADS)
Hasan, M. A.; Reaz, M. B. I.
2012-01-01
The aim of this paper is to model the algorithm for Fetal ECG (FECG) extraction from composite abdominal ECG (AECG) using VHDL (Very High Speed Integrated Circuit Hardware Description Language) for FPGA (Field Programmable Gate Array) implementation. Artificial Neural Network that provides efficient and effective ways of separating FECG signal from composite AECG signal has been designed. The proposed method gives an accuracy of 93.7% for R-peak detection in FHR monitoring. The designed VHDL model is synthesized and fitted into Altera's Stratix II EP2S15F484C3 using the Quartus II version 8.0 Web Edition for FPGA implementation.
Age-dependent loss of the C-terminal amino acid from alpha crystallin
NASA Technical Reports Server (NTRS)
Emmons, T.; Takemoto, L.; Spooner, B. S. (Principal Investigator)
1992-01-01
Antiserum made against the C-terminal region of alpha-A crystallin was used to monitor the purification of a tryptic peptide containing the C-terminus of the molecule from fetal versus adult bovine lenses. Mass spectral analysis of the peptide preparations obtained from these lenses demonstrated the presence of a peptide (T20) containing an intact C-terminus from fetal lenses and the presence of an additional peptide (T20') from older lenses that contained a cleaved C-terminal serine. These results demonstrate an age-dependent processing of alpha-A crystallin in the bovine lens, resulting in removal of the C-terminal amino acid residue.
Successful electrical cardioversion of supraventricular tachycardia in a pregnant patient
Yılmaz, Fevzi; Beydilli, Inan; Kavalcı, Cemil; Yılmaz, Serkan
2012-01-01
Summary Background: Pregnancy can precipitate cardiac arrhythmias not previously present in seemingly well individuals. Atrial and ventricular premature beats are frequently present during pregnancy and are usually benign. Supraventricular tachycardia and malignant ventricular tachyarrhythmias occur less frequently. Maternal and fetal arrhythmias occurring during pregnancy may jeopardize the life of the mother and the fetus. Case Report: A 32-year-old pregnant women at 26 weeks gestation presented to the emergency department with palpitation. She had mild chest discomfort after a supraventricular tachycardia (SVT) episode but did not have syncope. After monitoring and access of an IV line, vagal manoeuvres were applied but the rhythm was resistant. Then she was treated with 5 mg metoprolol IV, but the SVT persisted. Then after IV infusion of adenosine triphosphate 6 to 12 mg, the rhythm was resistant. Synchronized cardioversion with 100 joules was performed. Patients’ rhythm was normalized to a sinus rhythm. She was discharged from hospital without any adverse effects following 24-hour monitoring. Conclusions: All pregnant patients with SVT require careful maternal and fetal monitoring during treatment, and close collaboration between the managing obstetrician and the cardiologist is essential. PMID:23569481
Transabdominal ultrasound for pregnancy diagnosis in Reeves' muntjac deer.
Walton, Kelly D; McNulty, Erin; Nalls, Amy V; Mathiason, Candace K
2014-01-07
Reeves' muntjac deer (Muntiacus reevesi) are a small cervid species native to southeast Asia, and are currently being investigated as a potential model of prion disease transmission and pathogenesis. Vertical transmission is an area of interest among researchers studying infectious diseases, including prion disease, and these investigations require efficient methods for evaluating the effects of maternal infection on reproductive performance. Ultrasonographic examination is a well-established tool for diagnosing pregnancy and assessing fetal health in many animal species(1-7), including several species of farmed cervids(8-19), however this technique has not been described in Reeves' muntjac deer. Here we describe the application of transabdominal ultrasound to detect pregnancy in muntjac does and to evaluate fetal growth and development throughout the gestational period. Using this procedure, pregnant animals were identified as early as 35 days following doe-buck pairing and this was an effective means to safely monitor the pregnancy at regular intervals. Future goals of this work will include establishing normal fetal measurement references for estimation of gestational age, determining sensitivity and specificity of the technique for diagnosing pregnancy at various stages of gestation, and identifying variations in fetal growth and development under different experimental conditions.
2006-06-30
Mexico suggested bringing together government agencies, academics, and industry representatives with an interest in medical simulation to identify ways...test, take online continuing medical education (CME) courses on electronic fetal monitoring and shoulder dystocia , and complete a physician
Perpetuating Myths, Fables, and Fairy Tales: A Half Century of Electronic Fetal Monitoring
Sartwelle, Thomas P.; Johnston, James C.; Arda, Berna
2015-01-01
Electronic fetal monitoring (EFM) entered clinical medical practice at the same time bioethics became reality. Bioethics changed the medical ethics landscape by replacing the traditional Hippocratic benign paternalism with patient autonomy, informed consent, beneficence, and nonmaleficence. But EFM use represents the polar opposite of bioethics' revered principles—it has been documented for half a century to be completely ineffectual, used without informed consent, and harmful to mothers and newborns alike. Despite EFM's ethical misuse, there has been no outcry from the bioethical world. Why? This article answers that question, discussing EFM's history and the reasons it was issued an ethics pass. And it explores the reason that even today mothers are still treated with blatant medical paternalism, deprived of autonomy and informed consent, and subjected to real medical risks under the guise that EFM is an essential safety device when in fact it is used almost solely to protect physicians and hospitals from cerebral palsy lawsuits. PMID:28824967
Langli Ersdal, Hege; Mduma, Estomih; Svensen, Erling; Sundby, Johanne; Perlman, Jeffrey
2012-01-01
Intermittent fetal heart rate (FHR) monitoring during labor using an acoustic stethoscope is the most frequent method for fetal assessment of well-being in low- and middle-income countries. Evidence concerning reliability and efficacy of this technique is almost nonexistent. To determine the value of routine intermittent FHR monitoring during labor in the detection of FHR abnormalities, and the relationship of abnormalities to the subsequent fresh stillbirths (FSB), birth asphyxia (BA), need for neonatal face mask ventilation (FMV), and neonatal deaths within 24 h. This is a descriptive observational study in a delivery room from November 2009 through December 2011. Research assistants/observers (n = 14) prospectively observed every delivery and recorded labor information including FHR and interventions, neonatal information including responses in the delivery room, and fetal/neonatal outcomes (FSB, death within 24 h, admission neonatal area, or normal). 10,271 infants were born. FHR was abnormal (i.e. <120 or >160 beats/min) in 279 fetuses (2.7%) and absent in 200 (1.9%). Postnatal outcomes included FSB in 159 (1.5%), need for FMV in 695 (6.8%), BA (i.e. 5-min Apgar score <7) in 69 (0.7%), and deaths in 89 (0.9%). Abnormal FHR was associated with labor complications (OR = 31.4; 95% CI: 23.1-42.8), increased need for FMV (OR = 7.8; 95% CI: 5.9-10.1), BA (OR = 21.7; 95% CI: 12.7-37.0), deaths (OR = 9.9; 95% CI: 5.6-17.5), and FSB (OR = 35; 95% CI: 20.3-60.4). An undetected FHR predicted FSB (OR = 1,983; 95% CI: 922-4,264). Intermittent detection of an absent or abnormal FHR using a fetal stethoscope is associated with FSB, increased need for neonatal resuscitation, BA, and neonatal death in a limited-resource setting. The likelihood of an abnormal FHR is magnified with labor complications. Copyright © 2012 S. Karger AG, Basel.
Roberts, Llinos A; Ling, Hua Zen; Poon, Liona; Nicolaides, Kypros H; Kametas, Nikos A
2018-04-01
To assess whether in a cohort of patients with small for gestational age (SGA) foetuses with estimated fetal weight ≤10 th percentile, maternal hemodynamics, fetal biometry and Dopplers at presentation, can predict the subsequent development of abnormal fetal Dopplers or delivery with birthweight <3 rd percentile. The study population comprised of 86 singleton pregnancies with SGA fetuses presenting at a median gestational age of 32 (range 26-35) weeks. We measured maternal cardiac function with a non-invasive transthoracic bioreactance monitor (NICOM, Cheetah), mean arterial pressure, fetal biometry, umbilical artery (UA), middle cerebral artery (MCA) and uterine artery (UT) pulsatility index (PI) and the deepest vertical pool (DVP) of amniotic fluid. Z-scores of these variables were calculated based on reported reference ranges and the values were compared between those with evidence of abnormal fetal Dopplers at presentation (group 1), those that developed abnormal Dopplers in subsequent visits (group 2) and those who did not develop abnormal Dopplers throughout pregnancy (group 3). Abnormal fetal Dopplers were defined as UAPI >95 th percentile, or MCA PI <5 th percentile. Differences in measured variables at presentation were also compared between pregnancies delivering a baby with birthweight <3 rd and ≥3 rd percentile. Multivariate logistic regression analysis was used to determine significant predictors of birthweight <3 rd percentile and evolution from normal fetal Dopplers to abnormal fetal Dopplers in groups 2 and 3. In the study population 14 (16%) cases were in group 1, 19 (22%) in group 2 and 53 (62%) in group 3. The birthweight was <3 rd percentile in 39 (45%) cases and ≥3 rd percentile in 47 (55%). In the study groups, compared to normal populations, there was decreased cardiac output and stroke volume and increased peripheral vascular resistance and mean arterial pressure (MAP) and the deviations from normal were most marked in group 1. Pregnancies with a birthweight <3 rd , compared to those ≥3 rd percentile, had higher deviations from normal in fetal biometry, maternal cardiac output, stroke volume, heart rate and peripheral vascular resistance and UT-PI. Multivariate logistic regression analysis demonstrated that in the prediction of birth weight ≤3 rd percentile, maternal hemodynamics provided significant improvement to the prediction provided by maternal demographics, fetal biometry and UT-PI, UA-PI and MCA-PI (difference between AUCs 0.18, 95% CI 0.06-0.29, p=0.002). In contrast, there was no significant independent contribution from maternal hemodynamics in the prediction of subsequent abnormal fetal Dopplers. In pregnancies with SGA fetuses there is decreased maternal cardiac output and stroke volume and increased peripheral vascular resistance and MAP and the deviations from normal are most marked in cases of redistribution in the fetal circulation and reduced amniotic fluid volume. This article is protected by copyright. All rights reserved.
Monitoring fetal pH by telemetry
NASA Technical Reports Server (NTRS)
Blum, A.; Donahoe, T.; Jhabvala, M. D.; Ryan, W.
1980-01-01
Telemetry unit has been developed for possible use in measuring scalp-tissue pH and heart rate of unborn infant. Unit radius data to receiver as much as 50 ft. away. Application exists during hours just prior to childbirth to give warning of problems that might require cesarean delivery.
Therapeutic drug monitoring of antithyroid drugs in pregnancy: the knowledge gaps.
Koren, Gideon; Soldin, Offie
2006-02-01
Despite being a common condition in pregnancy, and despite propylthiouracil (PTU) being perceived as safer than methimazole, there are virtually no epidemiological controlled studies on malformation rate an neurobehavioral outcomes with the former. This knowledge gap must be filled to ensure fetal safety.
Intermittent auscultation (IA) of fetal heart rate in labour for fetal well-being.
Martis, Ruth; Emilia, Ova; Nurdiati, Detty S; Brown, Julie
2017-02-13
The goal of fetal monitoring in labour is the early detection of a hypoxic baby. There are a variety of tools and methods available for intermittent auscultation (IA) of the fetal heart rate (FHR). Low- and middle-income countries usually have only access to a Pinard/Laënnec or the use of a hand-held Doppler device. Currently, there is no robust evidence to guide clinical practice on the most effective IA tool to use, timing intervals and length of listening to the fetal heart for women during established labour. To evaluate the effectiveness of different tools for IA of the fetal heart rate during labour including frequency and duration of auscultation. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (19 September 2016), contacted experts and searched reference lists of retrieved articles. All published and unpublished randomised controlled trials (RCTs) or cluster-RCTs comparing different tools and methods used for intermittent fetal auscultation during labour for fetal and maternal well-being. Quasi-RCTs, and cross-over designs were not eligible for inclusion. All review authors independently assessed eligibility, extracted data and assessed risk of bias for each trial. Data were checked for accuracy. We included three studies (6241 women and 6241 babies), but only two studies are included in the meta-analyses (3242 women and 3242 babies). Both were judged as high risk for performance bias due to the inability to blind the participants and healthcare providers to the interventions. Evidence was graded as moderate to very low quality; the main reasons for downgrading were study design limitations and imprecision of effect estimates. Intermittent Electronic Fetal Monitoring (EFM) using Cardiotocography (CTG) with routine Pinard (one trial)There was no clear difference between groups in low Apgar scores at five minutes (reported as < six at five minutes after birth) (risk ratio (RR) 0.66, 95% confidence interval (CI) 0.24 to 1.83, 633 babies, very low-quality evidence). There were no clear differences for perinatal mortality (RR 0.88, 95% CI 0.34 to 2.25; 633 infants, very low-quality evidence). Neonatal seizures were reduced in the EFM group (RR 0.05, 95% CI 0.00 to 0.89; 633 infants, very low-quality evidence). Other important infant outcomes were not reported: mortality or serious morbidity (composite outcome), cerebral palsy or neurosensory disability. For maternal outcomes, women allocated to intermittent electronic fetal monitoring (EFM) (CTG) had higher rates of caesarean section for fetal distress (RR 2.92, 95% CI 1.78 to 4.80, 633 women, moderate-quality evidence) compared with women allocated to routine Pinard. There was no clear difference between groups in instrumental vaginal births (RR 1.46, 95% CI 0.86 to 2.49, low-quality evidence). Other outcomes were not reported (maternal mortality, instrumental vaginal birth for fetal distress and or acidosis, analgesia in labour, mobility or restriction during labour, and postnatal depression). Doppler ultrasonography with routine Pinard (two trials)There was no clear difference between groups in Apgar scores < seven at five minutes after birth (reported as < six in one of the trials) (average RR 0.76, 95% CI 0.20 to 2.87; two trials, 2598 babies, I 2 = 72%, very low-quality evidence); there was high heterogeneity for this outcome. There was no clear difference between groups for perinatal mortality (RR 0.69, 95% CI 0.09 to 5.40; 2597 infants, two studies, very low-quality evidence), or neonatal seizures (RR 0.05, 95% CI 0.00 to 0.91; 627 infants, one study, very low-quality evidence). Other important infant outcomes were not reported (cord blood acidosis, composite of mortality and serious morbidity, cerebral palsy, neurosensory disability). Only one study reported maternal outcomes. Women allocated to Doppler ultrasonography had higher rates of caesarean section for fetal distress compared with those allocated to routine Pinard (RR 2.71, 95% CI 1.64 to 4.48, 627 women, moderate-quality evidence). There was no clear difference in instrumental vaginal births between groups (RR 1.35, 95% CI 0.78 to 2.32, 627 women, low-quality evidence). Other maternal outcomes were not reported. Intensive Pinard versus routine Pinard (one trial)One trial compared intensive Pinard (a research midwife following the protocol in a one-to-one care situation) with routine Pinard (as per protocol but midwife may be caring for more than one woman in labour). There was no clear difference between groups in low Apgar score (reported as < six this trial) (RR 0.90, 95% CI 0.35 to 2.31, 625 babies, very low-quality evidence). There were also no clear differences identified for perinatal mortality (RR 0.56, 95% CI 0.19 to 1.67; 625 infants, very low-quality evidence), or neonatal seizures (RR 0.68, 95% CI 0.24 to 1.88, 625 infants, very low-quality evidence)). Other infant outcomes were not reported. For maternal outcomes, there were no clear differences between groups for caesarean section or instrumental delivery (RR 0.70, 95% CI 0.35 to 1.38, and RR 1.21, 95% CI 0.69 to 2.11, respectively, 625 women, both low-quality evidence)) Other outcomes were not reported. Using a hand-held (battery and wind-up) Doppler and intermittent CTG with an abdominal transducer without paper tracing for IA in labour was associated with an increase in caesarean sections due to fetal distress. There was no clear difference in neonatal outcomes (low Apgar scores at five minutes after birth, neonatal seizures or perinatal mortality). Long-term outcomes for the baby (including neurodevelopmental disability and cerebral palsy) were not reported. The quality of the evidence was assessed as moderate to very low and several important outcomes were not reported which means that uncertainty remains regarding the use of IA of FHR in labour.As intermittent CTG and Doppler were associated with higher rates of caesarean sections compared with routine Pinard monitoring, women, health practitioners and policy makers need to consider these results in the absence of evidence of short- and long-term benefits for the mother or baby.Large high-quality randomised trials, particularly in low-income settings, are needed. Trials should assess both short- and long-term health outcomes, comparing different monitoring tools and timing for IA.
Fetal heart rate and fetal heart rate variability in Lipizzaner broodmares.
Baska-Vincze, Boglárka; Baska, Ferenc; Szenci, Ottó
2015-03-01
Monitoring fetal heart rate (FHR) and fetal heart rate variability (FHRV) helps to understand and evaluate normal and pathological conditions in the foal. The aim of this study was to establish normal heart rate reference values for the ongoing equine pregnancy and to perform a heart rate variability (HRV) time-domain analysis in Lipizzaner mares. Seventeen middle- and late-term (days 121-333) pregnant Lipizzaner mares were examined using fetomaternal electrocardiography (ECG). The mean FHR (P = 0.004) and the standard deviation of FHR (P = 0.012) significantly decreased during the pregnancy. FHR ± SD values decreased from 115 ± 35 to 79 ± 9 bpm between months 5 and 11. Our data showed that HRV in the foal decreased as the pregnancy progressed, which is in contrast with the findings of earlier equine studies. The standard deviation of normal-normal intervals (SDNN) was higher (70 ± 25 to 166 ± 108 msec) than described previously. The root mean square of successive differences (RMSSD) decreased from 105 ± 69 to 77 ± 37 msec between the 5th and 11th month of gestation. Using telemetric ECG equipment, we could detect equine fetal heartbeat on day 121 for the first time. In addition, the large differences observed in the HR values of four mare-fetus pairs in four consecutive months support the assumption that there might be 'high-HR' and 'low-HR' fetuses in horses. It can be concluded that the analysis of FHR and FHRV is a promising tool for the assessment of fetal well-being but the applicability of these parameters in the clinical setting and in studs requires further investigation.
Van Leeuwen, Peter; Werner, Lisa; Hilal, Ziad; Schiermeier, Sven; Hatzmann, Wolfgang; Grönemeyer, Dietrich
2014-03-01
This study examines signal availability in fetal electrocardiogram (FECG) beat-to-beat acquisition and the accuracy of fetal heart rate variability (HRV) analysis in the clinical setting using a commercially available FECG monitor. Signal availability was examined in 130 FECG recordings of 0.3-17.5 h duration collected in 63 fetuses (25th-42nd week of gestation) under uncontrolled conditions. Identification of R-peaks demonstrated a signal loss of 30% ± 24% with 3.6 ± 1.7 signal gaps per minute. Median duration of the gaps within a recording was 1.8 ± 0.2 s. Per hour of recording, 1.8 ± 2.1 episodes of 5 min of uninterrupted data were found. Signal availability improved with gestational age and was poorer in women with high body-mass index. Fetal HRV between weeks 36-42 was examined on the basis of 5 min RR-interval episodes obtained under controlled quiet conditions in 55 FECG compared to 46 high quality fetal magnetocardiograms. There were no differences in RR-interval duration, its standard deviation and low frequency power. However, various measures of short-term HRV were significantly higher in the FECG data: root mean square of successive differences (10.0 ± 1.8 versus 6.6 ± 3.0 ms, p < 0.001, high frequency spectral power (24 ± 12 versus 13 ± 13 ms(2), p < 0.001) and approximate entropy (0.86 ± 0.16 versus 0.73 ± 0.24, p = 0.007). We conclude that, in spite of considerable signal loss, FECG recordings can accurately estimate heart rate and its overall variance. However, measures that quantify short-term beat-to-beat HRV will be compromised due to possible recurring inappropriate detection of single R-peaks.
Hansen, Craig A; Barnett, Adrian G; Pritchard, Gary
2008-03-01
Over the past decade there has been mounting evidence that ambient air pollution during pregnancy influences fetal growth. This study was designed to examine possible associations between fetal ultrasonic measurements collected from 15,623 scans (13-26 weeks gestation) and ambient air pollution during early pregnancy. We calculated mothers' average monthly exposures over the first 4 months of pregnancy for the following pollutants: particulate matter < 10 microm aerodynamic diameter (PM10), ozone, nitrogen dioxide, and sulfur dioxide. We examined associations with fetal femur length (FL), biparietal diameter (BPD), head circumference (HC), and abdominal circumference (AC). Final analyses included scans from only those women within 2 km of an air pollution monitoring site. We controlled for long-term trend, season, temperature, gestation, mother's age, socioeconomic status, and fetal sex. A reduction in fetal AC was associated with O3 during days 31-60 [-1.42 mm; 95% confidence interval (CI), -2.74 to -0.09], SO2 during days 61-90 (-1.67 mm; 95% CI, -2.94 to -0.40), and PM10 during days 91-120 (-0.78 mm; 95% CI, -1.49 to -0.08). Other results showed a reduction in BPD (-0.68 mm; 95% CI, -1.09 to -0.27) associated with SO2 during days 0-30, a reduction in HC (-1.02 mm; 95% CI, -1.78 to -0.26) associated with PM10 during days 91-120, and a reduction in FL associated with PM10 during days 0-30 (-0.28 mm; 95% CI, -0.48 to -0.08) and 91-120 (-0.23; 95% CI, -0.42 to -0.04). We found strong effects of ambient air pollution on ultrasound measures. Future research, including more individually detailed data, is needed to confirm our results.
Doret, Muriel; Spilka, Jiří; Chudáček, Václav; Gonçalves, Paulo; Abry, Patrice
2015-01-01
Background The fetal heart rate (FHR) is commonly monitored during labor to detect early fetal acidosis. FHR variability is traditionally investigated using Fourier transform, often with adult predefined frequency band powers and the corresponding LF/HF ratio. However, fetal conditions differ from adults and modify spectrum repartition along frequencies. Aims This study questions the arbitrariness definition and relevance of the frequency band splitting procedure, and thus of the calculation of the underlying LF/HF ratio, as efficient tools for characterizing intrapartum FHR variability. Study Design The last 30 minutes before delivery of the intrapartum FHR were analyzed. Subjects Case-control study. A total of 45 singletons divided into two groups based on umbilical cord arterial pH: the Index group with pH ≤ 7.05 (n = 15) and Control group with pH > 7.05 (n = 30). Outcome Measures Frequency band-based LF/HF ratio and Hurst parameter. Results This study shows that the intrapartum FHR is characterized by fractal temporal dynamics and promotes the Hurst parameter as a potential marker of fetal acidosis. This parameter preserves the intuition of a power frequency balance, while avoiding the frequency band splitting procedure and thus the arbitrary choice of a frequency separating bands. The study also shows that extending the frequency range covered by the adult-based bands to higher and lower frequencies permits the Hurst parameter to achieve better performance for identifying fetal acidosis. Conclusions The Hurst parameter provides a robust and versatile tool for quantifying FHR variability, yields better acidosis detection performance compared to the LF/HF ratio, and avoids arbitrariness in spectral band splitting and definitions. PMID:26322889
A Comparative Study on Fetal Heart Rates Estimated from Fetal Phonography and Cardiotocography
Ibrahim, Emad A.; Al Awar, Shamsa; Balayah, Zuhur H.; Hadjileontiadis, Leontios J.; Khandoker, Ahsan H.
2017-01-01
The aim of this study is to investigate that fetal heart rates (fHR) extracted from fetal phonocardiography (fPCG) could convey similar information of fHR from cardiotocography (CTG). Four-channel fPCG sensors made of low cost (<$1) ceramic piezo vibration sensor within 3D-printed casings were used to collect abdominal phonogram signals from 20 pregnant mothers (>34 weeks of gestation). A novel multi-lag covariance matrix-based eigenvalue decomposition technique was used to separate maternal breathing, fetal heart sounds (fHS) and maternal heart sounds (mHS) from abdominal phonogram signals. Prior to the fHR estimation, the fPCG signals were denoised using a multi-resolution wavelet-based filter. The proposed source separation technique was first tested in separating sources from synthetically mixed signals and then on raw abdominal phonogram signals. fHR signals extracted from fPCG signals were validated using simultaneous recorded CTG-based fHR recordings.The experimental results have shown that the fHR derived from the acquired fPCG can be used to detect periods of acceleration and deceleration, which are critical indication of the fetus' well-being. Moreover, a comparative analysis demonstrated that fHRs from CTG and fPCG signals were in good agreement (Bland Altman plot has mean = −0.21 BPM and ±2 SD = ±3) with statistical significance (p < 0.001 and Spearman correlation coefficient ρ = 0.95). The study findings show that fHR estimated from fPCG could be a reliable substitute for fHR from the CTG, opening up the possibility of a low cost monitoring tool for fetal well-being. PMID:29089896
Oximeter for reliable clinical determination of blood oxygen saturation in a fetus
Robinson, Mark R.; Haaland, David M.; Ward, Kenneth J.
1996-01-01
With the crude instrumentation now in use to continuously monitor the status of the fetus at delivery, the obstetrician and labor room staff not only over-recognize the possibility of fetal distress with the resultant rise in operative deliveries, but at times do not identify fetal distress which may result in preventable fetal neurological harm. The invention, which addresses these two basic problems, comprises a method and apparatus for non-invasive determination of blood oxygen saturation in the fetus. The apparatus includes a multiple frequency light source which is coupled to an optical fiber. The output of the fiber is used to illuminate blood containing tissue of the fetus. In the preferred embodiment, the reflected light is transmitted back to the apparatus where the light intensities are simultaneously detected at multiple frequencies. The resulting spectrum is then analyzed for determination of oxygen saturation. The analysis method uses multivariate calibration techniques that compensate for nonlinear spectral response, model interfering spectral responses and detect outlier data with high sensitivity.
Paris, A; Maurice-Tison, S; Coatleven, F; Vandenbossche, F; Dallay, D; Horovitz, J
2012-06-01
To compare the interest of lactate microanalysis with pH measurement (Gold Standard procedure) in cord blood and fetal scalp blood samples for the assessment of abnormal fetal heart rate (FHR) during labour. A prospective observational study conducted from July 1st 2007 till March 31st 2008 on 162 patients with abnormal FHR during labour. Sampling failure for scalp lactate was less than 1 % compared to a failure of 10.5 % for scalp pH (P<0.001). There was a good correlation between pH and lactates in fetal scalp blood samples and in cord blood samples, between lactate in the last fetal scalp sample and in cord blood. When there was umbilical acidosis (pH≤7.15 or lactate≥5mmol/L), Apgar score at 5 minutes was significantly lower than when there was no acidosis (4.66±3.59 versus 8.35±2.73 for pH ; 6.6±3.77 versus 8.45±2.58 for lactate). The specificity of the lactate in the umbilical cord artery (≥5 mmol/laws) was 76.4 % for predicting an Apgar score at 5 minutes less than 7 ; 79.7 % for predicting the need for immediate neonatal care ; 77.3 % for predicting an hospital stay in neonatal unit. These figures were generally worse but close to those found for a threshold value of umbilical artery pH≤7.15. The values of lactate in cord blood and fetal scalp blood samples were comparable to pH values (Gold standard procedure). This method is easy to perform and is an attractive alternative to pH for monitoring fetal asphyxia. It is our opinion that the combination of the two methods is of interest. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Assessing the impact of total extracorporeal circulation on hemodynamics in an ovine fetal model.
Xiao, Fei; Zhuang, Jian; Zhou, Cheng-Bin; Chen, Ji-Mei; Cen, Jian-Zheng; Xu, Gang; Wen, Shu-Sheng
2017-09-01
The present study aimed to evaluate the impact of total extracorporeal circulation on hemodynamics and placental function in an ovine fetal model. Mid-term ovine fetuses (n=6) underwent extracorporeal circulation (30 min), cardioplegic arrest (20 min) and monitoring (120 min). The ascending aorta and umbilical cords of the fetuses were occluded during the bypass and an extracorporeal membrane oxygenator was used as the oxygen source. Biventricular intracardiac pressures, echocardiographic data, blood gas levels and placental function variables were recorded, and statistical analysis was performed using the repeated-measure analysis of variance test. The data indicated that fetal heart rate and blood pressure at 30, 60, 90 and 120 min following the bypass were stable relative to pre-arrest baseline (pre-bypass) values (P>0.05). However, end diastolic pressures in the ovine right ventricles post-bypass were significantly increased at 30, 60, 90 and 120 min relative to pre-bypass pressures (P<0.05). The pulsatility index also increased at 30 min post-bypass relative to the pre-bypass score (0.91±0.06 vs. 0.61±0.14; P=0.007). The mean resistivity index at all time points post-bypass was consistent with the pre-bypass score (P>0.05), while the mean Tei index values for the left and right ventricles post-bypass were significantly higher at all time points relative to pre-bypass values (P<0.05). The pre-bypass fetal blood pH, SaO 2 , base excess and lactate values were maintained during arrest (P>0.05). Fetal hemodynamics and placental function additionally remained stable for up to 2 h upon reperfusion following total extracorporeal circulation and cardioplegic arrest. Collectively these data suggest that the reproducible ovine fetal model may be useful in the evaluation of fetal cardiac surgery.
[Pregnancy in systemic autoimmune diseases: Myths, certainties and doubts].
Danza, Álvaro; Ruiz-Irastorza, Guillermo; Khamashta, Munther
2016-10-07
Systemic autoimmune diseases especially affect young women during childbearing age. The aim of this review is to update systemic lupus erythematosus, antiphospholipid syndrome and systemic sclerosis management during pregnancy. These diseases present variable maternal and fetal risks. Studies show that an appropriate disease control and a reasonable remission period prior to pregnancy are associated with satisfactory obstetric outcomes. Antiphospholipid autoantibodies profile, anti-Ro/anti-La antibodies, pulmonary pressure and activity evaluation are crucial to assess the pregnancy risk. Monitoring requires a multidisciplinary team, serial analytic controls and Doppler ultrasound of maternal and fetal circulation. Evaluation of the activity of the disease is essential. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.
Haker, Björn; Fuchs, Sigrid; Dierlamm, Judith; Brümmendorf, Tim H; Wege, Henning
2007-10-18
As a culture model to study hepatocarcinogenesis, telomerase-immortalized human fetal hepatocytes were monitored for karyotype changes evolving in long-term culture and development of functional defects in DNA damage response. G-banding revealed acquisition of characteristic karyotype abnormalities, e.g., trisomy 7 and monosomy X, in two independently immortalized and cultured populations after 80-100 population doublings. Interestingly, the detected aneuploidies resemble some of the genetic events observed in hepatocellular cancer. However, these genetic changes were not sufficient to induce oncogenic transformation reflected by absence of anchorage-independent growth. Furthermore, long-term cultured telomerase-immortalized cells preserved p53 expression levels and effective p53-mediated damage response.
Assessment of the fetus: relevance to brain injury.
Hill, A
1989-06-01
This article reviews recent advances in the antepartum and intrapartum assessment of the fetus and their relationship to brain injury in the newborn. The antepartum assessment involves observation of fetal body and eye movements, the nonstress and contraction stress tests, measurement of amniotic fluid volume, the fetal biophysical score and measurement of fetoplacental blood physiology. There is evidence to suggest that seizures may either be epileptic in origin or initiated and mediated by nonepileptic mechanisms. Therapeutic decisions may be based on bedside assessment of the pathophysiology of observed seizures. Although EEG/video monitoring plays a role in the management of neonatal seizures, clinical evaluation of the seizures may provide initial data critical to decisions concerning immediate management.
Uauy, R; Casanello, P; Krause, B; Kuzanovic, J P; Corvalan, C
2013-09-01
Healthy growth in utero and after birth is fundamental for lifelong health and wellbeing. The World Health Organization (WHO) recently published standards for healthy growth from birth to 6 years of age; analogous standards for healthy fetal growth are not currently available. Current fetal growth charts in use are not true standards, since they are based on cross-sectional measurements of attained size under conditions that do not accurately reflect normal growth. In most cases, the pregnant populations and environments studied are far from ideal; thus the data are unlikely to reflect optimal fetal growth. A true standard should reflect how fetuses and newborns 'should' grow under ideal environmental conditions. The development of prescriptive intrauterine and newborn growth standards derived from the INTERGROWTH-21(st) Project provides the data that will allow us for the first time to establish what is 'normal' fetal growth. The INTERGROWTH-21(st) study centres provide the data set obtained under pre-established standardised criteria, and details of the methods used are also published. Multicentre study with sites in all major geographical regions of the world using a standard evaluation protocol. These standards will assess risk of abnormal size at birth and serve to evaluate potentially effective interventions to promote optimal growth beyond securing survival. The new normative standards have the potential to impact perinatal and neonatal survival and beyond, particularly in developing countries where fetal growth restriction is most prevalent. They will help us identify intrauterine growth restriction at earlier stages of development, when preventive or corrective strategies might be more effective than at present. These growth standards will take us one step closer to effective action in preventing and potentially reversing abnormal intrauterine growth. Achieving 'optimal' fetal growth requires that we act not only during pregnancy but that we optimize the maternal uterine environment from the time before conception, through embryonic development until fetal growth is complete. The remaining challenge is how 'early' will we be able to act, now that we can better monitor fetal growth. © 2013 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2013 RCOG.
East, Christine E; Kane, Stefan C; Davey, Mary-Ann; Kamlin, C Omar; Brennecke, Shaun P
2015-11-03
The rate of caesarean sections around the world is rising each year, reaching epidemic proportions. Although many caesarean sections are performed for concerns about fetal welfare on the basis of abnormal cardiotocography, the majority of babies are shown to be well at birth, meaning that the operation, with its inherent short and long term risks, could have been avoided without compromising the baby's health. Previously, fetal scalp blood sampling for pH estimation was performed in the context of an abnormal cardiotocograph, to improve the identification of babies in need of expedited delivery. This test has largely been replaced by lactate measurement, although its validity is yet to be established through a randomised controlled trial. This study aims to test the hypothesis that the performance of fetal scalp blood lactate measurement for women in labour with an abnormal cardiotocograph will reduce the rate of birth by caesarean section from 38 % to 25 % (a 35 % relative reduction). Prospective unblinded randomised controlled trial conducted at a single tertiary perinatal centre. Women labouring with a singleton fetus in cephalic presentation at 37 or more weeks' gestation with ruptured membranes and with an abnormal cardiotocograph will be eligible. Participants will be randomised to one of two groups: fetal monitoring by cardiotocography alone, or cardiotocography augmented by fetal scalp blood lactate analysis. Decisions regarding the timing and mode of delivery will be made by the treating team, in accordance with hospital protocols. The primary study endpoint is caesarean section with secondary outcomes collected from maternal, fetal and neonatal clinical course and morbidities. A cost effectiveness analysis will also be performed. A sample size of 600 will provide 90 % power to detect the hypothesised difference in the proportion of women who give birth by caesarean section. This world-first trial is adequately powered to determine the impact of fetal scalp blood lactate measurement on rates of caesarean section. Preventing unnecessary caesarean sections will reduce the health and financial burdens associated with this operation, both in the index and any future pregnancies. Australian New Zealand Clinical Trials Registry ACTRN12611000172909.
Maturation of Human Fetal Responses to Vibroacoustic Stimulation.
ERIC Educational Resources Information Center
Kisilevsky, Barbara S.; And Others
1992-01-01
Fetuses received vibroacoustic stimulation while movement and heart rate were monitored. From 29 weeks, at least 83 percent of fetuses responded to stimulation with heart rate acceleration. Between 26 and 36 weeks, the percentage of fetuses responding to stimulation with movement increased from 58 to 100 percent. (BC)
Holding Fixture For Making Piezoelectric Acoustic Sensors
NASA Technical Reports Server (NTRS)
Hall, E. Thomas, Jr.
1993-01-01
Vacuum holding device provides quick and easy method of bonding together two strips of thin film with fast-setting epoxy adhesive. Fixture holds films in place by vacuum while adhesive applied, maintaining uniform bond line between films, providing internal connection port between nickel coats on films for center conductor of coaxial cable, and eliminating need to clean up excessive adhesive. Used to fabricate acoustic sensors for use in ambulatory fetal heart monitors. Potential for other heart-monitoring applications and other applications in which acoustic sensors used.
Ultrasonographic monitoring of a spontaneous abortion in an owl monkey (Aotus nancymaae).
Schuler, A Michele; Parks, Virginia L; Abee, Christian R; Scammell, Jonathan G
2007-07-01
This case report describes the ultrasonographic findings during an idiopathic spontaneous abortion in an owl monkey. The female owl monkey presented for a transabdominal ultrasonogram to evaluate her pregnancy. This evaluation is a routine monitoring procedure in our owl monkey breeding colony. Although the fetus and placenta appeared normal at the initial scan, no fetal heartbeat could be detected. We followed the abortion with serial ultrasonographic scans and documented complete involution of the uterus post-abortion.
Ayres-de-Campos, Diogo; Rei, Mariana; Nunes, Inês; Sousa, Paulo; Bernardes, João
2017-01-01
SisPorto 4.0 is the most recent version of a program for the computer analysis of cardiotocographic (CTG) signals and ST events, which has been adapted to the 2015 International Federation of Gynaecology and Obstetrics (FIGO) guidelines for intrapartum foetal monitoring. This paper provides a detailed description of the analysis performed by the system, including the signal-processing algorithms involved in identification of basic CTG features and the resulting real-time alerts.
Fetal spasms after the administration of electroconvulsive therapy in pregnancy: our experience.
Halmo, Martin; Spodniaková, Barbara; Nosáľová, Petra
2014-09-01
Most psychotropic drugs are not approved for use during pregnancy. Electroconvulsive therapy (ECT) might be an effective and safe treatment option for several psychiatric disorders in pregnant women. This study assessed ECT for treating major psychoses during pregnancy, taking all possible adverse effects into account. We scrutinized all biomedical reviews on ECT during pregnancy published within the past 10 years, and present our experience with 3 patients in different phases of pregnancy that were treated with ECT between December 2009 and July 2012. Four to 5 ECT sessions were administered to pregnant women (10th to 28th week of pregnancy) with severe psychoses, and fetal heartbeat and movements were monitored during ECT and for 2 hours afterward. Bizarre fetal spasms occurred in pregnant women treated with ECT. The authors are not aware of any similar description in the published reviews on this topic, to date. Still, all 3 women had successful deliveries, and the infants remained healthy during follow-ups ranging from 1 to 3.5 years. These data fill a lacking gap in the literature regarding long-term infant outcomes after ECT administration to pregnant women. This supports the theory that ECT may be an excellent treatment solution for pregnant women with certain severe mental disorders. Electroconvulsive therapy may be an acceptable approach for preventing pharmacotherapy risks or danger arising from injuries associated with mental illnesses in pregnant women. Nonetheless, careful monitoring of both mother and baby is absolutely necessary when considering ECT during pregnancy.
Stochastic time series analysis of fetal heart-rate variability
NASA Astrophysics Data System (ADS)
Shariati, M. A.; Dripps, J. H.
1990-06-01
Fetal Heart Rate(FHR) is one of the important features of fetal biophysical activity and its long term monitoring is used for the antepartum(period of pregnancy before labour) assessment of fetal well being. But as yet no successful method has been proposed to quantitatively represent variety of random non-white patterns seen in FHR. Objective of this paper is to address this issue. In this study the Box-Jenkins method of model identification and diagnostic checking was used on phonocardiographic derived FHR(averaged) time series. Models remained exclusively autoregressive(AR). Kalman filtering in conjunction with maximum likelihood estimation technique forms the parametric estimator. Diagnosrics perfonned on the residuals indicated that a second order model may be adequate in capturing type of variability observed in 1 up to 2 mm data windows of FHR. The scheme may be viewed as a means of data reduction of a highly redundant information source. This allows a much more efficient transmission of FHR information from remote locations to places with facilities and expertise for doser analysis. The extracted parameters is aimed to reflect numerically the important FHR features. These are normally picked up visually by experts for their assessments. As a result long term FHR recorded during antepartum period could then be screened quantitatively for detection of patterns considered normal or abnonnal. 1.
Gamma-linoleic acid and ascorbate improves skeletal ossification in offspring of diabetic rats.
Braddock, Rattana; Simán, C Martin; Hamilton, Katherine; Garland, Hugh O; Sibley, Colin P
2002-05-01
Maternal diabetes causes a range of complications in offspring, including reduced skeletal ossification. This study examined whether feeding gamma-linoleic acid (GLA) and ascorbate, alone or in combination, to diabetic pregnant rats improves skeletal development in their offspring. In addition, Ca(2+) concentration was monitored in maternal plasma and fetal tissue, as well as placental mRNA expression of calbindin-D(9k). Female rats rendered diabetic with streptozotocin were fed GLA (500 mg/kg/d), ascorbate (290 mg/kg/d), ascorbyl-GLA (790 mg/kg/d), or GLA and ascorbate (500 and 290 mg/kg/d, respectively) throughout pregnancy. Fetal skeletons were studied after alizarin red staining. Fewer ossification centers were observed in offspring of diabetic rats compared with offspring of control rats (68 +/- 4% of control, p = 0.01). An almost complete restoration of ossification occurred with all the treatments (92-95 +/- 3% of control). The effects of treatment on fetal ossification could not be explained by altered maternal plasma Ca(2+) concentrations or by mRNA expression of the placental Ca(2+)-transporting protein calbindin-D(9K). We conclude that GLA and/or ascorbate treatment was effective against diabetes-induced fetal ossification defects by a mechanism not related to placental Ca(2+) supply.
Green, Benedict T; Panter, Kip E; Lee, Stephen T; Welch, Kevin D; Pfister, James A; Gardner, Dale R; Stegelmeier, Bryan L; Davis, T Zane
2015-11-01
Calves with congenital defects born to cows that have grazed teratogenic Lupinus spp. during pregnancy can suffer from what is termed crooked calf syndrome. Crooked calf syndrome defects include cleft palate, spinal column defects and limb malformations formed by alkaloid-induced inhibition of fetal movement. In this study, we tested the hypothesis that there are differences in fetal activity of fetuses carried by Holstein verses Angus heifers orally dosed with 1.1 g/kg dried ground Lupinus leucophyllus. Fetal activity was monitored via transrectal ultrasonography and maternal serum was analyzed for specific lupine alkaloids. There were more (P < 0.05) movements in fetuses of Holstein heifers than those in Angus heifers at eight and 12 h after oral dosing. In addition to serum alkaloid toxicokinetic differences, the Holstein heifers had significantly lower serum concentrations of anagyrine at 2, 4, and 8 h after oral dosing than Angus heifers. Holstein heifers also had significantly greater serum concentrations of lupanine at 12, 18 and 24 h after dosing than the Angus heifers. These results suggest that there are breed differences in susceptibility to lupine-induced crooked calf syndrome. These differences may also be used to discover genetic markers that identify resistant animals, thus facilitating selective breeding of resistant herds. Published by Elsevier Ltd.
VandeVoort, Catherine A.; Gerona, Roy R.; vom Saal, Frederick S.; Tarantal, Alice F.; Hunt, Patricia A.; Hillenweck, Anne; Zalko, Daniel
2016-01-01
The present study was conducted in pregnant rhesus monkeys to determine the rapidity and extent to which BPA reaches the fetal compartment following oral ingestion, and the 24-hr fate of BPA. To assess metabolism changes during the course of pregnancy, we compared BPA biotransformation during the second and third trimesters in the same animals, measuring the levels of sulfated, gluronidated, and free BPA in maternal serum, amniotic fluid, and fetal serum. All animals showed measurable unconjugated and conjugated BPA in the fetal compartment and slow clearance compared to maternal serum. There were higher levels of BPA-G in amniotic fluid at 150 days gestation compared to 100 days gestation, as well as higher levels of BPA-G than BPA-S. We also monitored 3H-BPA (and metabolites) in key tissues and excreta from a mother and fetus and from a non-pregnant female. The elimination of radioactivity was rapid, but residues were still detectable 24 hr after dosing in all tissues analyzed. These data suggest that, in primates, rapid maternal processing of BPA does not alleviate the risk of exposure to the developing fetus. This study elevates concerns about levels of current BPA human exposure from potentially a large number of unknown sources and the risks posed to developing fetuses. PMID:27930651
Sex differences in the fetal heart rate variability indices of twins.
Tendais, Iva; Figueiredo, Bárbara; Gonçalves, Hernâni; Bernardes, João; Ayres-de-Campos, Diogo; Montenegro, Nuno
2015-03-01
To evaluate the differences in linear and complex heart rate dynamics in twin pairs according to fetal sex combination [male-female (MF), male-male (MM), and female-female (FF)]. Fourteen twin pairs (6 MF, 3 MM, and 5 FF) were monitored between 31 and 36.4 weeks of gestation. Twenty-six fetal heart rate (FHR) recordings of both twins were simultaneously acquired and analyzed with a system for computerized analysis of cardiotocograms. Linear and nonlinear FHR indices were calculated. Overall, MM twins presented higher intrapair average in linear indices than the other pairs, whereas FF twins showed higher sympathetic-vagal balance. MF twins exhibited higher intrapair average in entropy indices and MM twins presented lower entropy values than FF twins considering the (automatically selected) threshold rLu. MM twin pairs showed higher intrapair differences in linear heart rate indices than MF and FF twins, whereas FF twins exhibited lower intrapair differences in entropy indices. The results of this exploratory study suggest that twins have sex-specific differences in linear and nonlinear indices of FHR. MM twins expressed signs of a more active autonomic nervous system and MF twins showed the most active complexity control system. These results suggest that fetal sex combination should be taken into consideration when performing detailed evaluation of the FHR in twins.
Carotid blood flow changes with behavioral states in the late gestation llama fetus in utero.
Blanco, C E; Giussani, D A; Riquelme, R A; Hanson, M A; Llanos, A J
1997-12-19
This study tested the hypothesis that in the llama fetus changes in cerebral blood flow are closely associated with changes in cerebral oxidative metabolism such as occur during transitions between electrocortical states. For the first time reported in any species, instantaneous changes in common carotid blood flow, employed as a continuous index of cerebrovascular perfusion, were related to instantaneous changes in electrocortical activity. Three late gestation fetal llamas were surgically prepared under general anesthesia with vascular catheters, a tracheal and amniotic catheter, and with electrodes implanted to monitor the fetal electrocorticogram (ECoG). In addition, Transonic flow probes were placed around a common carotid artery and a femoral artery. At least 4 days after surgery fetal arterial blood, amniotic and tracheal pressures, carotid and femoral blood flows and the fetal ECoG were recorded continuously. Our results suggest a close association between increases in common carotid blood flow and low voltage ECoG in the llama fetus. Close coupling between instantaneous changes in carotid blood flow and electrocortical states together with the lack of an increase in brain blood flow without increased cerebral oxygen extraction during hypoxemia in the llama fetus supports a fall in cerebral oxidative metabolism in this species during hypoxemic episodes.
Asymptomatic bacteriuria in pregnancy: a diagnostic and therapeutic approach.
Grio, R; Porpiglia, M; Vetro, E; Uligini, R; Piacentino, R; Minì, D; Marchino, G L
1994-12-01
Pregnancy is a predisposing factor for urinary tract infection and pregnant women suffering from this pathology are exposed to dangerous risks which may condition maternal wellbeing and fetal prognosis. The apparently paradoxal finding of a higher incidence of perinatal problems in pregnant women with asymptomatic bacteriuria compared to those with manifest infections may be explained by the fact that the latter are adequately treated, whereas asymptomatic bacteriuria, which is difficult to diagnose, may continue in a subtle form for the entire duration of pregnancy. This emphasises the importance of the early diagnosis of infection using a protocol based on urine tests and urine culture and the adequate treatment of all cases of asymptomatic bacteriuria in order to reduce the incidence of maternal and fetal complications (acute pyelonephritis, increased fetal morbidity and mortality). The choice of the antibiotic to be used must be made on the basis of the urine culture test, the stage of gestation, maternal clinical data and the characteristics of the antibiotic itself (pharmacokinetics, maternal and fetal toxicity). With regard to the treatment protocol, the "single-dose" protocol is currently preferred. After negative urine culture tests, all patients must carry out a complete urine test each month with hormonal and echographic monitoring of the fetoplacental unit.
A novel method to estimate safety factor of capture by a fetal micropacemaker.
Vest, Adriana Nicholson; Zhou, Li; Bar-Cohen, Yaniv; Eli Loeb, Gerald
2016-07-01
We have developed a rechargeable fetal micropacemaker in order to treat severe fetal bradycardia with comorbid hydrops fetalis, a life-threatening condition in pre-term non-viable fetuses for which there are no effective treatment options. The small size and minimally invasive form factor of our design limit the volume available for circuitry and a power source. The device employs a fixed-rate and fixed-amplitude relaxation oscillator and a tiny, rechargeable lithium ion power cell. For both research and clinical applications, it is valuable to monitor the electrode-myocardium interface in order to determine that adequate pacemaker output is being provided. This is typically accomplished by observing the minimal stimulus strength that achieves threshold for pacing capture. The output of our simple micropacemaker cannot be programmatically altered to determine this minimal capture threshold, but a safety factor can be inferred by determining the refractory period for ventricular capture at a given stimulus strength. This is done by measuring the minimal timing between naturally occurring QRS complexes and pacing stimuli that successfully generate a premature ventricular contraction. The method was tested in a pilot study in four fetal sheep and the data demonstrate that a relative measure of threshold is obtainable. This method provides valuable real-time information about the electrode-tissue interface.
Bourtembourg, A; Ramanah, R; Martin, A; Pugin-Vivot, A; Maillet, R; Riethmuller, D
2015-06-01
Expulsion upon vaginal delivery is a period at risk for the foetus, especially in case of breech presentation. In fact, monitoring the fetal well-being is complex in this phase. The correct interpretation of fetal heart rate (FHR) during expulsion, using Melchior's classification, is important because it helps screen for fetal acidosis. The aim of this study was to determine if it was possible to tolerate an abnormal FHR during expulsion of breech presentations. A retrospective study was conducted to compare FHR during expulsion and neonatal results between breech and cephalic presentations at Besançon's university hospital. We collected data from 118 breech presentations and 236 cephalic presentations. Melchior's FHR classification types were significantly different between breech and cephalic presentations with a majority of type 1. Neonatal results were significantly less favorable for breech presentations, but without any increase in mortality and in severe morbidity. Melchior's expulsion FHR classification seems to be applicable for breech presentations with a different distribution of FHR types compared to cephalic presentations. Following the results of this study, it seems to be possible to tolerate an abnormal FHR during expulsion of breech presentation, so far as is reasonable. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
A novel method to estimate safety factor of capture by a fetal micropacemaker
Vest, Adriana Nicholson; Zhou, Li; Bar-Cohen, Yaniv; Loeb, Gerald Eli
2016-01-01
We have developed a rechargeable fetal micropacemaker in order to treat severe fetal bradycardia with comorbid hydrops fetalis, a life-threatening condition in pre-term non-viable fetuses for which there are no effective treatment options. The small size and minimally invasive form factor of our design limit the volume available for circuitry and a power source. The device employs a fixed-rate and fixed-amplitude relaxation oscillator and a tiny, rechargeable lithium ion power cell. For both research and clinical applications, it is valuable to monitor the electrode-myocardium interface in order to determine that adequate pacemaker output is being provided. This is typically accomplished by observing the minimal stimulus strength that achieves threshold for pacing capture. The output of our simple micropacemaker cannot be programmatically altered to determine this minimal capture threshold, but a safety factor can be inferred by determining the refractory period for ventricular capture at a given stimulus strength. This is done by measuring the minimal timing between naturally occurring QRS complexes and pacing stimuli that successfully generate a premature ventricular contraction. The method was tested in a pilot study in 4 fetal sheep and the data demonstrate that a relative measure of threshold is obtainable. This method provides valuable real-time information about the electrode-tissue interface. PMID:27340134
Schnorbusch, Kathy; Lembrechts, Robrecht; Brouns, Inge; Pintelon, Isabel; Timmermans, Jean-Pierre; Adriaensen, Dirk
2012-01-01
We recently developed an ex vivo lung slice model that allows for confocal live cell imaging (LCI) of neuroepithelial bodies (NEBs) in postnatal mouse lungs (postnatal days 1-21 and adult). NEBs are morphologically well-characterized, extensively innervated groups of neuroendocrine cells in the airway epithelium, which are shielded from the airway lumen by 'Clara-like' cells. The prominent presence of differentiated NEBs from early embryonic development onwards, strongly suggests that NEBs may exert important functions during late fetal and neonatal life. The main goal of the present study was to adapt the current postnatal LCI lung slice model to enable functional studies of fetal mouse lungs (gestational days 17-20).In vibratome lung slices of prenatal mice, NEBs could be unequivocally identified with the fluorescent stryryl pyridinium dye 4-Di-2-ASP. Changes in the intracellular free calcium concentration and in mitochondrial membrane potential could be monitored using appropriate functional fluorescent indicators (e.g. Fluo-4).It is clear that the described fetal mouse lung slice model is suited for LCI studies of Clara cells, ciliated cells, and the NEB microenvironment, and offers excellent possibilities to further unravel the significance of NEBs during the prenatal and perinatal period.
Web-based comparison of historical vs contemporary methods of fetal heart rate interpretation.
Epstein, Aaron J; Iriye, Brian K; Hancock, Lyle; Quilligan, Edward J; Rumney, Pamela J; Hancock, Judy; Ghamsary, Mark; Eakin, Cortney M; Smith, Cheryl; Wing, Deborah A
2016-10-01
Contemporary interpretation of fetal heart rate patterns is based largely on the tenets of Drs Quilligan and Hon. This method differs from an older method that was championed by Dr Caldeyro-Barcia in recording speed and classification of decelerations. The latter uses a paper speed of 1 cm/min and classifies decelerations referent to uterine contractions as type I or II dips, compared with conventional classification as early, late, or variable with paper speed of 3 cm/min. We hypothesized that 3 cm/min speed may lead to over-analysis of fetal heart rate and that 1 cm/min may provide adequate information without compromising accuracy or efficiency. The purpose of this study was to compare the Hon-Quilligan method of fetal heart rate interpretation with the Caldeyro-Barcia method among groups of obstetrics care providers with the use of an online interactive testing tool. We deidentified 40 fetal heart rate tracings from the terminal 30 minutes before delivery. A website was created to view these tracings with the use of the standard Hon-Quilligan method and adjusted the same tracings to the 1 cm/min monitoring speed for the Caldeyro-Barcia method. We invited 2-4 caregivers to participate: maternal-fetal medicine experts, practicing maternal-fetal medicine specialists, maternal-fetal medicine fellows, obstetrics nurses, and certified nurse midwives. After completing an introductory tutorial and quiz, they were asked to interpret the fetal heart rate tracings (the order was scrambled) to manage and predict maternal and neonatal outcomes using both methods. Their results were compared with those of our expert, Edward Quilligan, and were compared among groups. Analysis was performed with the use of 3 measures: percent classification, Kappa, and adjusted Gwet-Kappa (P < .05 was considered significant). Overall, our results show from moderate to almost perfect agreement with the expert and both between and within examiners (Gwet-Kappa 0.4-0.8). The agreement at each stratum of practitioner was generally highest for ascertainment of baseline and for management; the least agreement was for assessment of variability. We examined the agreement of fetal heart rate interpretation with a defined set of rules among a number of different obstetrics practitioners using 3 different statistical methods and found moderate-to-substantial agreement among the clinicians for matching the interpretation of the expert. This implies that the simpler Caldeyro-Barcia method may perform as well as the newer classification system. Copyright © 2016 Elsevier Inc. All rights reserved.
Ropacka-Lesiak, Mariola; Lebioda, Anna; Breborowicz, Grzegorz
2012-09-01
A case of an umbilical cord collision diagnosed in the first trimester of a monochorionic monoamniotic twin pregnancy is presented. An intensive surveillance included ultrasound monitoring with color and spectral Doppler and fetal echocardiography. The first signs of fetal distress were observed at 31 weeks of gestation. The brain sparing effect as well as a periodic appearance of the "notch" in the wave forms obtained from the umbilical artery from the collision region were observed. In the first ultrasound scan there were no abnormalities in twin I. In contrast, in twin II a vascular resistance in the umbilical artery was at the upper limit for the gestational age. Five days later, decreased vascular resistance in the middle cerebral artery, which fluctuated at the lower limit, was noticed in twin II. After the next four days, PI in the middle cerebral artery decreased below the lower limit and tricuspid regurgitation appeared. In twin I the vascular resistance in the umbilical artery increased and remained at the upper limit of the reference ranges. Cardiotocographic records did not reveal signs of fetal distress. After a week the signs of brain sparing effect were visible in both fetuses. However, twin II showed features of umbilical cord clamping in the form of abnormal blood flow waveforms in the umbilical artery ("notch"). Therefore, despite the absence of signs of fetal distress in CTG in monochorionic monoamniotic twins with growth discordance of 20% and exponents of periodical clamping of the umbilical cord in twin II at 34 weeks, the decision to perform a caesarean section was made. The patient gave birth to two daughters (twin I: weight 1780g, Ap 10, pH 7.39, 7.40, BE -3.0, -2.6, and twin II: weight 1860g, Ap 10, pH 7.29, 7.35, BE -1.4, -2.4). During the delivery the umbilical cords collision was found at the region close to the body of twins. This case presents the possibility of using ultrasound and Doppler in the early diagnosis, monitoring and surveillance of pregnancies complicated by umbilical cords collision in monochorionic monoamniotic twins from the first trimester. Application of these methods allowed a safe monitoring of the fetuses and the identification of the onset of the cords collision. This in turn allowed the achievement of fetal maturity at 34 weeks, when both the risk of death and neonatal morbidity are significantly minimized. The use of Doppler blood flow velocimetry allowed the diagnosis of umbilical cords tightening before there were any signs of cardiac dysfunction in the CTG. This enabled to determine the most favorable, earlier time for delivery. The paper presents diagnostic management and surveillance in monochorionic monoamniotic pregnancy complicated by umbilical cord collision since the early pregnancy.
Robeck, Todd R; Gill, Claudia; Doescher, Bethany M; Sweeney, Jay; De Laender, Piet; Van Elk, Cornelis E; O'Brien, Justine K
2012-06-01
Progesterone production is essential for growth and development of the conceptus during pregnancy. Abnormal development of the corpus luteum (CL) after conception can result in early embryonic loss or fetal abortion. Routine monitoring of bottlenose dolphin (Tursiops truncatus) pregnancy after artificial insemination or natural conception with ultrasonography and serum progesterone determination has allowed for the establishment of expected fetal growth rates and hormone concentrations. Using these monitoring techniques, we revealed four pregnant dolphins (12-24 yr old) with abnormally low progesterone production indicative of luteal insufficiency. Once diagnosed, animals were placed on altrenogest (0.044-0.088 mg/kg once daily) alone or with oral progesterone (50-200 mg twice daily). Doses of hormone were increased or decreased in each animal based on how fetal skull biparietal and thoracic growth rates compared with published normal values. Hormones were withdrawn starting from day 358 of gestation in animals 1 and 2, with labor occurring 6 and 7 days after withdrawal and at 376 and 373 days of gestation, respectively. Both deliveries were dystocic, with each calf requiring manual extraction and fetotomy for calf 1. The fetuses in animals 3 and 4 died at 348 and 390 days of gestation, respectively. Induction of labor was attempted in both animals, after fetal death, by using a combination of rapid progesterone withdrawal and steroid and prostaglandin F2alpha administration. The calf of animal 4 had to be removed with manual cervical dilation and fetotomy All adult females survived the procedures. These data provide the first in vivo evidence that the CL is the primary source of progesterone throughout pregnancy in the bottlenose dolphin. Until further characterization of hormones required during pregnancy and at parturition has been accomplished, the exogenous progestagen supplementation protocol described here cannot be recommended for treatment of progesterone insufficiency in bottlenose dolphins.
Monitoring human growth and development: a continuum from the womb to the classroom.
Villar, José; Papageorghiou, Aris T; Pang, Ruyan; Salomon, Laurent J; Langer, Ana; Victora, Cesar; Purwar, Manorama; Chumlea, Cameron; Qingqing, Wu; Scherjon, Sicco A; Barros, Fernando C; Carvalho, Maria; Altman, Douglas G; Giuliani, Francesca; Bertino, Enrico; Jaffer, Yasmin A; Cheikh Ismail, Leila; Ohuma, Eric O; Lambert, Ann; Noble, J Alison; Gravett, Michael G; Bhutta, Zulfiqar A; Kennedy, Stephen H
2015-10-01
A comprehensive set of fully integrated anthropometric measures is needed to evaluate human growth from conception to infancy so that consistent judgments can be made about the appropriateness of fetal and infant growth. At present, there are 2 barriers to this strategy. First, descriptive reference charts, which are derived from local, unselected samples with inadequate methods and poor characterization of their putatively healthy populations, commonly are used rather than prescriptive standards. The use of prescriptive standards is justified by the extensive biologic, genetic, and epidemiologic evidence that skeletal growth is similar from conception to childhood across geographic populations, when health, nutrition, environmental, and health care needs are met. Second, clinicians currently screen fetuses, newborn infants, and infants at all levels of care with a wide range of charts and cutoff points, often with limited appreciation of the underlying population or quality of the study that generated the charts. Adding to the confusion, infants are evaluated after birth with a single prescriptive tool: the World Health Organization Child Growth Standards, which were derived from healthy, breastfed newborn infants, infants, and young children from populations that have been exposed to few growth-restricting factors. The International Fetal and Newborn Growth Consortium for the 21st Century Project addressed these issues by providing international standards for gestational age estimation, first-trimester fetal size, fetal growth, newborn size for gestational age, and postnatal growth of preterm infants, all of which complement the World Health Organization Child Growth Standards conceptually, methodologically, and analytically. Hence, growth and development can now, for the first time, be monitored globally across the vital first 1000 days and all the way to 5 years of age. It is clear that an integrative approach to monitoring growth and development from pregnancy to school age is desirable, scientifically supported, and likely to improve care, referral patterns, and reporting systems. Such integration can be achieved only through the use of international growth standards, especially in increasingly diverse, mixed ancestry populations. Resistance to new scientific developments has been hugely problematic in medicine; however, we are confident that the obstetric and neonatal communities will join their pediatric colleagues worldwide in the adoption of this integrative strategy. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
2017-04-29
Continuous electronic fetal heart-rate monitoring is widely used during labour, and computerised interpretation could increase its usefulness. We aimed to establish whether the addition of decision-support software to assist in the interpretation of cardiotocographs affected the number of poor neonatal outcomes. In this unmasked randomised controlled trial, we recruited women in labour aged 16 years or older having continuous electronic fetal monitoring, with a singleton or twin pregnancy, and at 35 weeks' gestation or more at 24 maternity units in the UK and Ireland. They were randomly assigned (1:1) to decision support with the INFANT system or no decision support via a computer-generated stratified block randomisation schedule. The primary outcomes were poor neonatal outcome (intrapartum stillbirth or early neonatal death excluding lethal congenital anomalies, or neonatal encephalopathy, admission to the neonatal unit within 24 h for ≥48 h with evidence of feeding difficulties, respiratory illness, or encephalopathy with evidence of compromise at birth), and developmental assessment at age 2 years in a subset of surviving children. Analyses were done by intention to treat. This trial is completed and is registered with the ISRCTN Registry, number 98680152. Between Jan 6, 2010, and Aug 31, 2013, 47 062 women were randomly assigned (23 515 in the decision-support group and 23 547 in the no-decision-support group) and 46 042 were analysed (22 987 in the decision-support group and 23 055 in the no-decision-support group). We noted no difference in the incidence of poor neonatal outcome between the groups-172 (0·7%) babies in the decision-support group compared with 171 (0·7%) babies in the no-decision-support group (adjusted risk ratio 1·01, 95% CI 0·82-1·25). At 2 years, no significant differences were noted in terms of developmental assessment. Use of computerised interpretation of cardiotocographs in women who have continuous electronic fetal monitoring in labour does not improve clinical outcomes for mothers or babies. National Institute for Health Research. Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.
Home blood-pressure monitoring in a hypertensive pregnant population: cost minimisation study.
Xydopoulos, G; Perry, H; Sheehan, E; Thilaganathan, B; Fordham, R; Khalil, A
2018-03-08
Traditional monitoring of blood pressure in hypertensive pregnant women requires frequent visits to the maternity outpatient services. Home blood-pressure monitoring (HBPM) could offer a cost-saving alternative that is acceptable to patients. The main objective of this study was to undertake a health economic analysis of HBPM compared with traditional monitoring in hypertensive pregnant women. This was a case-control study. Cases were pregnant women with hypertension who had HBPM with or without the adjunct of a smartphone app, via a specially designed pathway. The control group were managed as per existing hospital guidelines. Specific outcome measures were the number of outpatient visits, inpatient bed stays and investigations performed. Maternal, fetal and neonatal adverse outcomes were also recorded. Health economic analysis was performed using two methods: direct cost comparison of the study dataset and process scenario modelling. There were 108 women in the HBPM group, of whom 29 recorded their results on the smartphone app (App-HBPM) and 79 in their notes (Non-app HBPM). The control group comprised of 58 patients. There were significantly more women with chronic hypertension in the HBPM group (49.1% vs 25.9%, P = 0.004). The HBPM group had significantly longer duration of monitoring (9 weeks vs 5 weeks P = 0.004) and started monitoring from an earlier gestation (30 weeks vs 33.6 weeks, P = 0.001). Despite these differences, the mean saving per week for HBPM compared with the control group was £200.69. For the App-HBPM cohort, the saving per week compared with the control group was £286.53. The process modelling method predicted savings of between £98.32 and £245.80 per week using HBPM compared to the traditional monitoring. HBPM in hypertensive pregnancies appears to be cost-saving compared with traditional monitoring, without compromising maternal, fetal or neonatal safety. Larger studies are required to confirm these findings. This article is protected by copyright. All rights reserved.
Evans, Mark I; Eden, Robert D; Britt, David W; Evans, Shara M; Schifrin, Barry S
2018-02-28
Even key opinion leaders now concede that electronic fetal monitoring (EFM) cannot reliably identify fetal acidemia which many vouch as the only labor mediated pathophysiologic precursor for cerebral palsy (CP). We have developed the "Fetal Reserve Index" - an algorithm combining five dynamic components of EFM (1. Rate, 2. Variability, 3. Accelerations, 4. Decelerations, and 5. Excessive uterine activity) considered individually that are combined with the presence of: 6. maternal, 7. obstetrical, and 8. fetal risk factors. Here, we compare this 8-point fetal reserve index (FRI) against the performance of ACOG monograph criteria and ACOG Category systems for predicting risk for both CP and the need for emergency operative delivery (EOD). We then studied how varied management for screen positives (Red zone-defined below) impacts the outcome of such cases. Four hundred twenty term patients were studied: all entered labor with normal EFMs and no apparent cause of harm except events of labor and delivery. Sixty subsequently developed CP, and 360 were apparently normal controls. An FRI, normal on all eight parameters scored 100%, 4 of the 8 was 50%, etc. We divided cases into Green zone >50%, Yellow 50-26%, and Red ≤25%. An FRI in the Red zone was considered a positive screen. We then compared performance metrics for the three evaluation schemes and differences between controls that reached Red against those controls whose worst scores were Green/Yellow. For detection of injury during labor, the FRI performed much better than the ACOG Category criteria (sensitivity 28%), and Category III (45%) (p < .001). All CP cases reached Red zone and were Red for a minimum of 2 hours (mean = 5.35 hours). Twenty-four% of controls reached Red, but were only Red for average of 1 hr. The incidence of low Apgar's, pH, FRI, and Lowest FRI increased progressively from Green/Yellow controls to red controls to CP cases. Irrespective, CP cases met ACOG Monograph criteria for labor injury less than 50% of the time. Only half of CP babies had umbilical artery pH values <7.00, and less than 50% showed Category III patterns. The earlier in labor the Red zone was reached, the more likely for a baby to develop CP or the mother to require an EOD regardless of fetal outcome. Successful intrauterine resuscitations (IR) diminished time spent in the Red zone and the need for EODs. FRI shows better discrimination for adverse fetal outcome and EOD than traditional EFM interpretation. The Category system is a very poor, subjective screening method as the vast majority of CP babies never reach the "action point" result of Category III. While reaching the Red zone does not ordain a bad outcome, how it is managed, does. Compared to CP cases, Red controls were delivered faster, had higher FRIs, and often had prompt management including IR maneuvers, which improved the FRI and lowered the risk of EODs even for cases with normal outcomes. With further study and validation, the quantitative FRI approach may replace the current, very subjective interpretation with a quantitative "lab test" approach.
Frusca, Tiziana; Todros, Tullia; Lees, Christoph; Bilardo, Caterina M
2018-02-01
Early-onset fetal growth restriction represents a particular dilemma in clinical management balancing the risk of iatrogenic prematurity with waiting for the fetus to gain more maturity, while being exposed to the risk of intrauterine death or the sequelae of acidosis. The Trial of Umbilical and Fetal Flow in Europe was a European, multicenter, randomized trial aimed to determine according to which criteria delivery should be triggered in early fetal growth restriction. We present the key findings of the primary and secondary analyses. Women with fetal abdominal circumference <10th percentile and umbilical pulsatility index >95th percentile between 26-32 weeks were randomized to 1 of 3 monitoring and delivery protocols. These were: fetal heart rate variability based on computerized cardiotocography; and early or late ductus venosus Doppler changes. A safety net based on fetal heart rate abnormalities or umbilical Doppler changes mandated delivery irrespective of randomized group. The primary outcome was normal neurodevelopmental outcome at 2 years. Among 511 women randomized, 362/503 (72%) had associated hypertensive conditions. In all, 463/503 (92%) of fetuses survived and cerebral palsy occurred in 6/443 (1%) with known outcome. Among all women there was no difference in outcome based on randomized group; however, of survivors, significantly more fetuses randomized to the late ductus venosus group had a normal outcome (133/144; 95%) than those randomized to computerized cardiotocography alone (111/131; 85%). In 118/310 (38%) of babies delivered <32 weeks, the indication was safety-net criteria: 55/106 (52%) in late ductus venosus, 37/99 (37%) in early ductus venosus, and 26/105 (25%) in computerized cardiotocography groups. Higher middle cerebral artery impedance adjusted for gestation was associated with neonatal survival without severe morbidity (odds ratio, 1.24; 95% confidence interval, 1.02-1.52) and infant survival without neurodevelopmental impairment at 2 years (odds ratio, 1.33; 95% confidence interval, 1.03-1.72) although birthweight and gestational age were more important determinants. Perinatal and 2-year outcome was better than expected in all randomized groups. Among survivors, 2-year neurodevelopmental outcome was best in those randomized to delivery based on late ductus venosus changes. Given a high rate of delivery based on the safety-net criteria, deciding delivery based on late ductus venosus changes and abnormal computerized fetal heart rate variability seems prudent. There is no rationale for delivery based on cerebral Doppler changes alone. Of note, most women with early-onset fetal growth restriction develop hypertension. Copyright © 2018 Elsevier Inc. All rights reserved.
Ultrasonographic features of the mule embryo, fetus and fetal-placental unit.
Paolucci, M; Palombi, C; Sylla, L; Stradaioli, G; Monaci, M
2012-01-15
The aim of this study was to establish baseline ultrasound data concerning the mule conceptus during gestation. Ten multiparous Trotter mares were artificially inseminated with chilled semen from an Amiatino jack donkey. Daily transrectal ultrasonography was carried out from the day of ovulation until Day 50 of gestation to determine the following: first detection of the embryonic vesicle (EV), mobility phase, EV diameter, day of EV fixation, changes in EV shape, date of yolk sac regression and embryo crown-rump length. Monthly ultrasonic assessments from Day 50 of gestation to term were carried out. These assessments included an evaluation of fetal well-being and the growth of the mule conceptus, which were monitored using the following variables: cardiac activity, fetal activity and presentation, fetal fluid echogenicity, combined thickness of the utero-placenta unit and fetal orbital and aortic diameter. Mule EV first detection was observed earlier (37% at Day 8) than that observed in the equine pregnancy. EV diameter at first detection was 4.6 ± 1.1 mm. At Day 10, 75% of EVs were detected. EV fixation occurred on Day 17.1 ± 1.1, with a mean EV diameter of 2.5 ± 0.2 cm. EV growth rate was 4.04 mm/day from Days 11 to 16, 0.4 mm/day from Days 16 to 28 and 1.78 mm/day from Days 28 to 45 of pregnancy. The embryo proper was first detected on Day 19.9 ± 1.9 (average length 2.4 ± 1.4 mm), and the embryonic heartbeat was first detected on Day 24 ± 2.4. The fetal carotid pulse was observed at six months of gestation and provided a good means by which to estimate fetal cardiac activity in advanced gestation. The fetal heart rate was recorded from Month 2 of gestation to term. The mean ± SD of the combined uteroplacental thickness was assessed at the cervical-placental junction and at the ventral abdomen in mares between Months 2 and 5 until term, respectively. An abnormal fetal-placental unit and fetal inactivity was observed in association with abortion. Mule-conceptus biometric measurements correlated significantly with the gestational age, and these data were used to predict an unusually large mule fetus, which might result in dystocia. In conclusion, we can assume that early diagnosis of pregnancy failure and assessment of fetal biophysical profile and growth charts could improve the chances of gestation completion in mule-pregnant mares. The early detection of mares at risk for an abnormal pregnancy or delivery may increase the success of prompt treatments, therefore preventing costly emergency procedures and allowing proper obstetrical and neonatal assistance. Copyright © 2012 Elsevier Inc. All rights reserved.
Mugyenyi, Godfrey R; Atukunda, Esther C; Ngonzi, Joseph; Boatin, Adeline; Wylie, Blair J; Haberer, Jessica E
2017-06-08
Over 3 million stillbirths occur annually in sub Saharan Africa; most occur intrapartum and are largely preventable. The standard of care for fetal heart rate (FHR) assessment in most sub-Saharan African settings is a Pinard Stethoscope, limiting observation to one person, at one point in time. We aimed to test the functionality and acceptability of a wireless FHR monitor that could allow for expanded monitoring capacity in rural Southwestern Uganda. In a mixed method prospective study, we enrolled 1) non-laboring healthy term pregnant women to wear the device for 30 min and 2) non-study clinicians to observe its use. The battery-powered prototype uses Doppler technology to measure fetal cardiotocographs (CTG), which are displayed via an android device and wirelessly transmit to cloud storage where they are accessible via a password protected website. Prototype functionality was assessed by the ability to obtain and transmit a 30-min CTG. Three obstetricians independently rated CTGs for readability and agreement between raters was calculated. All participants completed interviews on acceptability. Fifty pregnant women and 7 clinicians were enrolled. 46 (92.0%) CTGs were successfully recorded and stored. Mean scores for readability were 4.71, 4.71 and 4.83 (out of 5) with high agreement (intra class correlation 0.84; 95% CI 0.74 to 0.91). All pregnant women reported liking or really liking the device, as well as high levels of comfort, flexibility and usefulness of the prototype; all would recommend it to others. Clinicians described the prototype as portable, flexible, easy-to-use and a time saver. Adequate education for clinicians and women also seemed to improve correct usage and minimise concerns on safety of the device. This prototype wireless FHR monitor functioned well in a low-resource setting and was found to be acceptable and useful to both pregnant women and clinicians. The device also seemed to have potential to improve the experience of the users compared with standard of care and expand monitoring capacity in settings where bulky, wired or traditional equipment are unreliable. Further research needs to investigate the potential impact and cost of such innovations to improve perinatal outcomes.
Dry electrode bio-potential recordings.
Gargiulo, Gaetano; Bifulco, Paolo; McEwan, Alistair; Nasehi Tehrani, Joubin; Calvo, Rafael A; Romano, Maria; Ruffo, Mariano; Shephard, Richard; Cesarelli, Mario; Jin, Craig; Mohamed, Armin; van Schaik, André
2010-01-01
As wireless bio-medical long term monitoring moves towards personal monitoring it demands very high input impedance systems capable to extend the reading of bio-signal during the daily activities offering a kind of "stress free", convenient connection, with no need for skin preparation. In particular we highlight the development and broad applications of our own circuits for wearable bio-potential sensor systems enabled by the use of an FET based amplifier circuit with sufficiently high impedance to allow the use of passive dry electrodes which overcome the significant barrier of gel based contacts. In this paper we present the ability of dry electrodes in long term monitoring of ECG, EEG and fetal ECG.
East, Christine E; Leader, Leo R; Sheehan, Penelope; Henshall, Naomi E; Colditz, Paul B; Lau, Rosalind
2015-05-01
Fetal scalp blood sampling for lactate estimation may be considered following identification of an abnormal or non-reassuring fetal heart rate pattern. The smaller volume of blood required for this test, compared with the more traditional pH estimation, may improve sampling rates. The appropriate use of this practice mandates systematic review of its safety and clinical effectiveness prior to widespread introduction. To evaluate the effectiveness and risks of fetal scalp lactate sampling in the assessment of fetal well-being during labour, compared with no testing or alternative testing. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 January 2015). All published and unpublished randomised and quasi-randomised trials that compared fetal scalp lactate testing with no testing or alternative testing to evaluate fetal status in the presence of a non-reassuring cardiotocograph during labour. We used the standard methodological procedures of the Cochrane Pregnancy and Childbirth Group. Two review authors independently assessed the studies. The search identified two completed randomised controlled trials (RCTs) and two ongoing trials. The two published RCTs considered outcomes for 3348 mother-baby pairs allocated to either lactate or pH estimation of fetal blood samples when clinically indicated in labour. Overall, the published RCTs were of low or unclear risk of bias. There was a high risk of performance bias, because it would not have been feasible to blind clinicians or participants.No statistically significant between-group differences were found for neonatal encephalopathy (risk ratio (RR) 1.00, 95% confidence interval (CI) 0.32 to 3.09, one study, 2992 infants) or death. No studies reported neonatal seizures. We had planned to report death with other morbidities, for example, neonatal encephalopathy; however, the data were not available in a format suitable for this, therefore death due to congenital abnormality was considered alone. The three reported neonatal deaths occurred in babies with diaphragmatic hernias (n = 2) or congenital cardiac fibrosis (n = 1). All three babies had been randomised to the pH group and were not acidaemic at birth.There were no statistically significant differences for any of the pre-specified secondary fetal/neonatal/infant outcomes for which data were available. This included low Apgar score at five minutes (RR 1.13, 95% CI 0.76 to 1.68, two studies, 3319 infants) and admission to neonatal intensive care units (RR 1.02, 95% CI 0.83 to 1.25, one study, 2992 infants), or metabolic acidaemia (RR 0.91, 95% CI 0.60 to 1.36, one study, 2675 infants) considered within the studies, either overall or where data were available for those where fetal blood sampling had occurred within 60 minutes of delivery.Similar proportions of fetuses underwent additional tests to further evaluate well-being during labour, including scalp pH if in the lactate group or scalp lactate if in the pH group (RR 0.22, 95% CI 0.04 to 1.30, two studies, 3333 infants;Tau² 1.00, I² = 58%). Fetal blood sampling attempts for lactate and pH estimation were successful in 98.7% and 79.4% of procedures respectively in the one study that reported this outcome.There were no significant between-group differences in mode of birth or operative birth for non-reassuring fetal status, either for all women, or within the group where the fetal blood sample had been taken within 60 minutes of delivery (for example, caesarean section for all enrolled, RR 1.09, 95% CI 0.97 to 1.22, two studies, 3319 women; operative delivery for non-reassuring fetal status for all enrolled RR 1.02, 95% CI 0.93 to 1.11, one study, 2992 women).Neither study reported on adverse effects of fetal scalp lacerations or maternal anxiety. When further testing to assess fetal well-being in labour is indicated, fetal scalp blood lactate estimation is more likely to be successfully undertaken than pH estimation. Further studies may consider subgroup analysis by gestational age, the stage of labour and sampling within a prolonged second stage of labour. Additionally, we await the findings from the ongoing studies that compare allocation to no fetal blood sample with sampling for lactate and address longer-term neonatal outcomes, maternal satisfaction with intrapartum fetal monitoring and an economic analysis.
Ursem, Nicolette T C; Peters, Ingrid A; Kraan-van der Est, Mieke N; Reijerink-Verheij, Jacqueline C I Y; Knapen, Maarten F C M; Cohen-Overbeek, Titia E
2017-06-01
Since 2007 the second-trimester fetal anomaly scan is offered to all pregnant women as part of the national prenatal screening program in the Netherlands. Dutch population-based screening programs generally have a well-described system to achieve quality assurance. Because of the absence of a uniform system to monitor the actual performance of the fetal anomaly scan in 2012, we developed a standardized image-scoring method. The aim of this study was to evaluate the scanning performance of all sonographers in the southwestern region of the Netherlands using this image-scoring method. Each sonographer was requested to set up a digital portfolio. A portfolio consists of five logbooks from five different pregnant women, each containing 25 fetal anatomical structures and six biometric measures of randomly selected fetal anomaly scans. During the study period, 425 logbooks of 85 sonographers were assessed as part of the audit process. Seventy-three out of 85 sonographers (86%) met the criteria in the primary audit, and 12 sonographers required individual hands-on training. A successful assessment was achieved for 11 sonographers in the re-audit and one sonographer ceased her contract. Moreover, 2.1% of the required images were not digitally stored and therefore could not be reviewed. Quality assessment using the image-scoring method demonstrated that most of the sonographers met the expectations of the audit process, but those who had subpar performance met the expectations after retraining. © 2017 by the American Institute of Ultrasound in Medicine.
Huang, Jun; Mo, Jinhua; Zhao, Guili; Lin, Qiyin; Wei, Guanhui; Deng, Weinan; Chen, Dunjin; Yu, Bolan
2017-11-01
Although monitoring and diagnosis of fetal diseases in utero remains a challenge, metabolomics may provide an additional tool to study the etiology and pathophysiology of fetal diseases at a functional level. In order to explore specific markers of fetal disease, metabolites were analyzed in two separate sets of experiments using amniotic fluid from fetuses with Down syndrome (DS) as a model. Both sets included 10‑15 pairs of controls and cases, and amniotic fluid samples were processed separately; metabolomic fingerprinting was then conducted using UPLC‑MS. Significantly altered metabolites involved in respective metabolic pathways were compared in the two experimental sets. In addition, significantly altered metabolic pathways were further compared with the genomic characters of the DS fetuses. The data suggested that metabolic profiles varied across different experiments, however alterations in the 4 metabolic pathways of the porphyrin metabolism, bile acid metabolism, hormone metabolism and amino acid metabolism, were validated for the two experimental sets. Significant changes in metabolites of coproporphyrin III, glycocholic acid, taurochenodeoxycholate, taurocholate, hydrocortisone, pregnenolone sulfate, L‑histidine, L‑arginine, L‑glutamate and L‑glutamine were further confirmed. Analysis of these metabolic alterations was linked to aberrant gene expression at chromosome 21 of the DS fetus. The decrease in coproporphyrin III in the DS fetus may portend abnormal erythropoiesis, and unbalanced glutamine‑glutamate concentration was observed to be closely associated with abnormal brain development in the DS fetus. Therefore, alterations in amniotic fluid metabolites may provide important clues to understanding the etiology of fetal disease and help to develop diagnostic testing for clinical applications.
Postpartum acute kidney injury: a review of 99 cases.
Eswarappa, Mahesh; Madhyastha, P Rakesh; Puri, Sonika; Varma, Vijay; Bhandari, Aneesh; Chennabassappa, Gurudev
2016-07-01
Postpartum acute kidney injury (PPAKI) constitutes an important cause of obstetric AKI. It is associated with high maternal and fetal mortality in developing nations. The aim of this study is to survey the etiology and outcomes of PPAKI in a tertiary care Indian hospital. Ninety-nine patients, without prior comorbidities, treated for PPAKI, between 2005-2014 at M.S. Ramaiah Medical College, were included for analysis in this retrospective, observational study. AKI was analyzed in terms of maximal stage of renal injury attained as per RIFLE criteria. Outcomes included requirement for renal replacement therapy (RRT), maternal and fetal outcomes. PPAKI constituted 60% of all obstetric AKI cases. Median maternal age was 23 years and 52% of patients were primigravidas. Mean serum creatinine was 4.1 mg/dL. Failure (33%) and injury (31%) were the major categories as per RIFLE criteria. Thirty-nine percent of cases required RRT. Sepsis, particularly puerperal sepsis, was the leading causes of PPAKI (75% of cases) and maternal mortality (94% of deaths). Maternal and fetal mortality were 19% and 22% respectively. The incidence of cortical necrosis was 10.3%. Three patients required long-term RRT. In conclusion, consistent with other Indian literature, we report a high incidence of PPAKI. We found incremental mortality on moving from "Risk" to "Failure" category of RIFLE. PPAKI was associated with high maternal and fetal mortality with sepsis being the leading cause. Our study highlights the need for provision of better quality of maternal care and fetal monitoring to decrease mortality associated with PPAKI in developing countries.
Berry, Diane C; Boggess, Kim; Johnson, Quinetta B
2016-05-01
The obesity epidemic has fueled an epidemic of prediabetes and type 2 diabetes mellitus in women of childbearing age. This paper examines the state of the science on preconception and pregnancy management of women with type 2 diabetes to optimize outcomes for the women and their infants. In addition, the consequence of fetal programming as a result of suboptimal maternal glycemic control is discussed. The paper focuses on type 2 diabetes, not type 1 diabetes or gestational diabetes. Management of women with type 2 diabetes includes preconception counseling, preconception weight management and weight loss, proper weight gain during pregnancy, self-monitoring of blood glucose levels, medication, medical nutrition therapy, and exercise.
[Myocardiopathy diagnosed in utero in a mother with SS-A antibodies treated with plasmapheresis].
Arroyave, C M; Puente Ledezma, F; Montiel Amoroso, G; Martínez García, A C
1995-03-01
We report a 36 years old patient with Sjogren's syndrome, who during her second pregnancy, the product developed a miocardiopathy with complete heart block that was diagnosed in utero at 26 weeks of pregnancy. Simultaneously, laboratory data reported a SS-A/Ro titer of 1:50,000 with positive antiphospholipids antibodies. Patient was subjected three times to plasmapheresis with three blood volume exchange each time. During the procedures, we had monitor the product and no hemodinamic changes were observed. Unfortunately, 25 days later the patient reported absence of fetal movement and by ecosonography and Doppler was not observed fetal movement or cardiac function. This pregnancy ends in cesarea. The patient is in perfect clinical conditions under control using prednisone and methotrexate.
Complexity analysis of fetal heart rate preceding intrauterine demise.
Schnettler, William T; Goldberger, Ary L; Ralston, Steven J; Costa, Madalena
2016-08-01
Visual non-stress test interpretation lacks the optimal specificity and observer-agreement of an ideal screening tool for intrauterine fetal demise (IUFD) syndrome prevention. Computational methods based on traditional heart rate variability have also been of limited value. Complexity analysis probes properties of the dynamics of physiologic signals that are otherwise not accessible and, therefore, might be useful in this context. To explore the association between fetal heart rate (FHR) complexity analysis and subsequent IUFD. Our specific hypothesis is that the complexity of the fetal heart rate dynamics is lower in the IUFD group compared with controls. This case-control study utilized cases of IUFD at a single tertiary-care center among singleton pregnancies with at least 10min of continuous electronic FHR monitoring on at least 2 weekly occasions in the 3 weeks immediately prior to fetal demise. Controls delivered a live singleton beyond 35 weeks' gestation and were matched to cases by gestational age, testing indication, and maternal age in a 3:1 ratio. FHR data was analyzed using the multiscale entropy (MSE) method to derive their complexity index. In addition, pNNx, a measure of short-term heart rate variability, which in adults is ascribable primarily to cardiac vagal tone modulation, was also computed. 211 IUFDs occurred during the 9-year period of review, but only 6 met inclusion criteria. The median gestational age at the time of IUFD was 35.5 weeks. Three controls were matched to each case for a total of 24 subjects, and 87 FHR tracings were included for analysis. The median gestational age at the first fetal heart rate tracing was similar between groups (median [1st-3rd quartiles] weeks: IUFD cases: 34.7 (34.4-36.2); controls: 35.3 (34.4-36.1); p=.94). The median complexity of the cases' tracings was significantly less than the controls' (12.44 [8.9-16.77] vs. 17.82 [15.21-22.17]; p<.0001). Furthermore, the cases' median complexity decreased as gestation advanced whereas the controls' median complexity increased over time. However, this difference was not statistically significant [-0.83 (-2.03 to 0.47) vs. 0.14 (-1.25 to 0.94); p=.62]. The degree of short-term variability of FHR tracings, as measured by the pNN metric, was significantly lower (p<.005) for the controls (1.1 [0.8-1.3]) than the IUFD cases (1.3 [1.1-1.6]). FHR complexity analysis using multiscale entropy analysis may add value to other measures in detecting and monitoring pregnancies at the highest risk for IUFD. The decrease in complexity and short-term variability seen in the IUFD cases may reflect perturbations in neuroautonomic control due to multiple maternal-fetal factors. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Papageorghiou, Aris T; Kennedy, Stephen H; Salomon, Laurent J; Altman, Douglas G; Ohuma, Eric O; Stones, William; Gravett, Michael G; Barros, Fernando C; Victora, Cesar; Purwar, Manorama; Jaffer, Yasmin; Noble, Julia A; Bertino, Enrico; Pang, Ruyan; Cheikh Ismail, Leila; Lambert, Ann; Bhutta, Zulfiqar A; Villar, José
2018-02-01
The purpose of the INTERGROWTH-21 st project was to develop international, prescriptive standards for fetal growth assessed by ultrasound and fundal height, preterm postnatal growth, newborn size and body composition, maternal weight gain, and infant development at the age of 2 years. Hence, we have produced, based on World Health Organization recommendations, the first comprehensive set of international standards of optimal fetal and newborn growth that perfectly match the existing World Health Organization child growth standards. Uniquely, the same population was followed up longitudinally from 9 weeks of fetal life to 2 years of age, with growth, health, and nutritional status assessment at 2 years supporting the appropriateness of the population for construction of growth standards. The resulting package of clinical tools allows, for the first time, growth and development to be monitored from early pregnancy to infancy. The INTERGROWTH-21 st fetal growth standards, which are based on observing >4500 healthy pregnancies, nested in a study of >59,000 pregnancies from populations with low rates of adverse perinatal outcomes, show how fetuses should grow-rather than the more limited objective of past references, which describe how they have grown at specific times and locations. Our work has confirmed the fundamental biological principle that variation in human growth across different populations is mostly dependent on environmental, nutritional, and socioeconomic factors. We found that when mothers' nutritional and health needs are met and there are few environmental constraints on growth, <3.5% of the total variability of skeletal growth was due to differences between populations. We propose that not recognizing the concept of optimal growth could deprive the most vulnerable mothers and their babies of optimal care, because local growth charts normalize those at highest risk for growth restriction and overweight, and can be valuable for policymakers to ensure rigorous evaluation and effective resource allocation. We strongly encourage colleagues to join efforts to provide integrated, evidence-based growth monitoring to pregnant women and their infants worldwide. Presently, there are 23.3 million infants born small for gestational age in low- to middle-income countries according to the INTERGROWTH-21 st newborn size standards. We suggest that misclassification of these infants by using local charts could affect the delivery of optimal health care. Copyright © 2018. Published by Elsevier Inc.
Cortés-Hernández, J; Ordi-Ros, J; Paredes, F; Casellas, M; Castillo, F; Vilardell-Tarres, M
2002-06-01
Our aim was to assess the outcome of pregnancy in a cohort of patients with SLE and to evaluate clinical and laboratory markers for fetal outcome and maternal flares. Sixty patients with 103 pregnancies were evaluated prospectively between 1984 and 1999. There were 68 live births, 15 spontaneous abortions, 12 stillbirths and eight therapeutic abortions. Of liveborn infant births, 19 were premature, 24 had suffered intrauterine growth restriction and one had neonatal lupus. Maternal lupus flares occurred in 33% of pregnancies, mostly in the second trimester (26%) and in the post-partum period (51%). Flares during pregnancy showed a statistically significant association with discontinuation of chloroquine treatment, a history of more than three flares before gestation, and a SLEDAI (Systemic Lupus Erythematosus Disease Activity Index) score of >or=5 in these flares. Antiphospholipid antibodies, C3 hypocomplementaemia and hypertension during pregnancy were significantly associated with fetal loss, prematurity and intrauterine growth restriction. Patients with more active SLE and those with aPL antibodies and hypertension should be monitored and managed carefully during pregnancy.
Chudáček, V; Spilka, J; Janků, P; Koucký, M; Lhotská, L; Huptych, M
2011-08-01
Cardiotocography is the monitoring of fetal heart rate (FHR) and uterine contractions (TOCO), used routinely since the 1960s by obstetricians to detect fetal hypoxia. The evaluation of the FHR in clinical settings is based on an evaluation of macroscopic morphological features and so far has managed to avoid adopting any achievements from the HRV research field. In this work, most of the features utilized for FHR characterization, including FIGO, HRV, nonlinear, wavelet, and time and frequency domain features, are investigated and assessed based on their statistical significance in the task of distinguishing the FHR into three FIGO classes. We assess the features on a large data set (552 records) and unlike in other published papers we use three-class expert evaluation of the records instead of the pH values. We conclude the paper by presenting the best uncorrelated features and their individual rank of importance according to the meta-analysis of three different ranking methods. The number of accelerations and decelerations, interval index, as well as Lempel-Ziv complexity and Higuchi's fractal dimension are among the top five features.
Magenes, G; Bellazzi, R; Malovini, A; Signorini, M G
2016-08-01
The onset of fetal pathologies can be screened during pregnancy by means of Fetal Heart Rate (FHR) monitoring and analysis. Noticeable advances in understanding FHR variations were obtained in the last twenty years, thanks to the introduction of quantitative indices extracted from the FHR signal. This study searches for discriminating Normal and Intra Uterine Growth Restricted (IUGR) fetuses by applying data mining techniques to FHR parameters, obtained from recordings in a population of 122 fetuses (61 healthy and 61 IUGRs), through standard CTG non-stress test. We computed N=12 indices (N=4 related to time domain FHR analysis, N=4 to frequency domain and N=4 to non-linear analysis) and normalized them with respect to the gestational week. We compared, through a 10-fold crossvalidation procedure, 15 data mining techniques in order to select the more reliable approach for identifying IUGR fetuses. The results of this comparison highlight that two techniques (Random Forest and Logistic Regression) show the best classification accuracy and that both outperform the best single parameter in terms of mean AUROC on the test sets.
Sueters, Marieke; Oepkes, Dick
2014-02-01
Monochorionic twin pregnancies are well known to be at risk for a variety of severe complications, a true challenge for the maternal-fetal medicine specialist. With current standards of care, monochorionicity should be established in the first trimester. Subsequently, frequent monitoring using the appropriate diagnostic tools, and in-depth knowledge about the pathophysiology of all possible clinical presentations of monochorionic twin abnormalities, should lead to timely recognition, and appropriate management. Virtually all unique diseases found in monochorionic twins are directly related to placental angio-architecture. This, however, cannot be established reliably before birth. The clinician needs to be aware of the definitions and symptoms of twin-to twin transfusion syndrome, selective fetal growth restriction, twin anaemia-polycythaemia sequence, and twin reversed arterial perfusion sequence, to be able to recognise each disease and take the required action. In this chapter, we address current standards on correct and timely diagnoses of severe complications of monochorionic twin pregnancies. Copyright © 2014 Elsevier Ltd. All rights reserved.
Implementation of an Oxytocin Checklist to Improve Clinical Outcomes.
Sundin, Courtney; Mazac, Lauren; Ellis, Kathleen; Garbo, Candon
Oxytocin is one of the most common drugs administered in obstetrics. Since its designation as a high-alert medication by the Institute for Safe Medication Practices in 2007, there has been much attention to oxytocin administration during labor. Oxytocin is generally safe when administered correctly, but adverse perinatal outcomes can occur during uterine tachysystole. The purpose of this project was to evaluate and compare results of maternal and fetal outcomes of induction of labor for women at term prior to and after implementation of a newly developed oxytocin checklist. To evaluate the practice change associated with the implementation of the new oxytocin checklist, 200 cases based on retrospective medical record reviews were compared with 200 cases after implementation. Use of the checklist was associated with several significant clinical outcomes, including decreases in tachysystole, decreases in cesarean births for concern about fetal status based on electronic fetal monitoring data, decreases in length of first stage labor, and decreases in maximum dose of oxytocin. Results are similar to previous research. Early physician buy-in, clinical team education, and ongoing evaluation enhanced facilitation of the oxytocin checklist. Clinical outcomes were favorable.
Graham, Ian D; Logan, Jo; Davies, Barbara; Nimrod, Carl
2004-12-01
Decreasing the use of continuous electronic fetal monitoring and increasing professional labor support for low-risk pregnancies are recommended by the Society of Obstetricians and Gynecologists of Canada. This study explored factors influencing the successful (and unsuccessful) introduction of an evidence-based fetal health surveillance guideline. This qualitative case study was conducted at two tertiary and one community hospital. Data were collected in 14 clinician focus groups (51 nurses), followed by 8 interviews with nurse administrators and educators. Analysis of verbatim transcripts and unit records included coding and categorizing data to form profiles that were compared across hospitals. Implementation of the guideline recommendations in the hospital settings was affected by many different factors originating in the practice environment, with the potential adopters, and related to the characteristics of the guideline. The influences of these diverse factors interacted sometimes to magnify or counteract each other's effect. The physical setting, adopter concerns, and the medicolegal issues surrounding the guideline played critical roles in uptake. In addition, changes preceding the introduction of the recommendations, the institution's agenda, and nursing and medical leadership influenced the uptake of guideline recommendations. The number and experience of nurses in each setting and availability of equipment also affected guideline acceptance and use. When implementing best practice, it is important to identify organizational barriers to the change that will need managing by the appropriate level of administration in the organization. Careful tailoring of implementation interventions to the barriers originating with the potential adopters is also necessary. Be prepared for unanticipated effects.
Risk Factors for Dystocia in Pigtailed Macaques (Macaca nemestrina)
Stockinger, Diane E; Torrence, Anne E; Hukkanen, Renee R; Vogel, Keith W; Hotchkiss, Charlotte E; Ha, James C
2011-01-01
Dystocia (difficult labor) is an important component of the management of nonhuman primates and results in significant fetal and maternal morbidity and increased use of veterinary resources. Dystocias can arise from abnormalities of the maternal pelvis or fetus or uncoordinated uterine activity. Although risk factors for stillbirths have been established in nonhuman primates, risk factors for dystocias have not. The objective of this study was to determine maternal and fetal risk factors for dystocia in macaques. Retrospective data were collected from 83 pigtailed macaques (Macaca nemestrina) diagnosed with dystocia. The diagnosis of dystocia was made based on clinical or pathologic evidence. Maternal records of age, reproductive history, experimental history, clinical records, and fetal birth weight and any applicable fetal necropsy reports were reviewed. The gestational age of the fetus, the infant's birth weight, total previous births by the dam, and the proportions of both viable delivery (inverse effect) and surgical pregnancy interventions (direct effect) in the dam's history generated a model that maximized the experimental variance for predicting dystocia in the current pregnancy and explained 24% of the dystocia deliveries. The number of total previous births and proportion of previous cesarean sections accounted for the greatest effect. This model can identify individual dams within a colony that are at risk for dystocias and allow for changes in breeding colony management, more intense monitoring of dams at risk, or allocation of additional resources. PMID:21535929
Two-Dimensional Echocardiography Estimates of Fetal Ventricular Mass throughout Gestation.
Aye, Christina Y L; Lewandowski, Adam James; Ohuma, Eric O; Upton, Ross; Packham, Alice; Kenworthy, Yvonne; Roseman, Fenella; Norris, Tess; Molloholli, Malid; Wanyonyi, Sikolia; Papageorghiou, Aris T; Leeson, Paul
2017-08-12
Two-dimensional (2D) ultrasound quality has improved in recent years. Quantification of cardiac dimensions is important to screen and monitor certain fetal conditions. We assessed the feasibility and reproducibility of fetal ventricular measures using 2D echocardiography, reported normal ranges in our cohort, and compared estimates to other modalities. Mass and end-diastolic volume were estimated by manual contouring in the four-chamber view using TomTec Image Arena 4.6 in end diastole. Nomograms were created from smoothed centiles of measures, constructed using fractional polynomials after log transformation. The results were compared to those of previous studies using other modalities. A total of 294 scans from 146 fetuses from 15+0 to 41+6 weeks of gestation were included. Seven percent of scans were unanalysable and intraobserver variability was good (intraclass correlation coefficients for left and right ventricular mass 0.97 [0.87-0.99] and 0.99 [0.95-1.0], respectively). Mass and volume increased exponentially, showing good agreement with 3D mass estimates up to 28 weeks of gestation, after which our measurements were in better agreement with neonatal cardiac magnetic resonance imaging. There was good agreement with 4D volume estimates for the left ventricle. Current state-of-the-art 2D echocardiography platforms provide accurate, feasible, and reproducible fetal ventricular measures across gestation, and in certain circumstances may be the modality of choice. © 2017 S. Karger AG, Basel.
Computerized analysis of fetal heart rate variability signal during the stages of labor.
Annunziata, Maria Laura; Tagliaferri, Salvatore; Esposito, Francesca Giovanna; Giuliano, Natascia; Mereghini, Flavia; Di Lieto, Andrea; Campanile, Marta
2016-03-01
To analyze computerized cardiotocographic (cCTG) parameters (baseline fetal heart rate, baseline FHR; short term variability, STV; approximate entropy, ApEn; low frequency, LF; movement frequency, MF; high frequency, HF) in physiological pregnancy in order to correlate them with the stages of labor. This could provide more information for understanding the mechanisms of nervous system control of FHR during labor progression. A total of 534 pregnant women were monitored on cCTG from the 37th week before the onset of spontaneous labor and during the first and the second stage of labor. Statistical analysis was performed using Kruskal-Wallis test and Wilcoxon rank-sum test with the Bonferroni adjusted α (< 0.05). Statistically significant differences were seen between baseline FHR, MF and HF (P < 0.001), in which the first two were reduced and the third was increased when compared between pre-labor, and the first and second stages of labor. Differences between some of the stages were found for ApEn, LF and for LF/(HF + MF), where the first and the third were reduced and the second was increased. cCTG modifications during labor may reflect the physiologic increased activation of the autonomous nervous system. Using computerized fetal heart rate analysis during labor it may be possible to obtain more information from the fetal cardiac signal, in comparison with the traditional tracing. © 2016 Japan Society of Obstetrics and Gynecology.
Music-of-Light Stethoscope: A Demonstration of the Photoacoustic Effect
ERIC Educational Resources Information Center
Nikitichev, D. I.; Xia, W.; Hill, E.; Mosse, C. A.; Perkins, T.; Konyn, K.; Ourselin, S.; Desjardins, A. E.; Vercauteren, T.
2016-01-01
In this paper we present a system aimed at demonstrating the photoacoustic (PA) effect for educational purposes. PA imaging is a hybrid imaging modality that requires no contrast agent and has a great potential for spine and brain lesion characterisation, breast cancer and blood flow monitoring notably in the context of fetal surgery. It relies on…
USDA-ARS?s Scientific Manuscript database
Our objectives were to develop an ovine model for Escherichia coli-induced preterm delivery, and monitor E. coli (lux modified for photonic detection) invasion of the fetal environment—ewes (124 ± 18 d of gestation) received intrauterine inoculations using E. coli-lux as follows: control (n = 5), 1....
Stott, D; Papastefanou, I; Paraschiv, D; Clark, K; Kametas, N A
2017-01-01
To examine whether treatment for hypertension in pregnancy that is guided by serial monitoring of maternal central hemodynamics leads to a reduction in the rate of severe hypertension, defined as blood pressure ≥ 160/110 mmHg; and to assess the distinct longitudinal hemodynamic profiles associated with beta-blocker monotherapy, vasodilator monotherapy and dual agent therapy, and their relationships with outcomes, including fetal growth restriction. This was a prospective observational study at a dedicated antenatal hypertension clinic in a tertiary UK hospital. Fifty-two untreated women presenting with hypertension were recruited consecutively and started on treatment, either with a beta-blocker or a vasodilator. The choice of initial antihypertensive agent was determined according to a model constructed previously to predict the response to the beta-blocker labetalol in pregnant women needing antihypertensive treatment. At presentation, the demographic and maternal hemodynamic variables associated with a therapeutic response to labetalol, defined as blood pressure control < 140/90 mmHg with labetalol monotherapy throughout pregnancy, were ascertained and analyzed with logistic regression to create a model to predict sustained blood pressure control as described above. The women were reviewed regularly until delivery and underwent serial hemodynamic monitoring throughout pregnancy. If their blood pressure was elevated, the prediction model was referred to again to determine if alternative antihypertensive therapy, either with additional beta-blocker or a vasodilator, should be added. Treatment by referring to results of serial hemodynamic monitoring reduced the rate of severe antenatal hypertension from 18% to 3.8%. Seventy-seven percent of women were initially prescribed a beta-blocker and 23% a vasodilator. The group that maintained good blood pressure control with beta-blocker monotherapy had the best fetal and maternal outcomes. They had lower blood pressures at presentation and throughout gestation, demonstrated well-maintained cardiac output and had the lowest rates of fetal growth restriction. The groups that required dual therapy to control their blood pressure had persistently higher blood pressure and rate of fetal growth restriction. The groups that required vasodilator therapy due to high levels of peripheral vascular resistance, either at presentation or later in pregnancy, accounted for 81% of cases with fetal growth restriction. Using serial hemodynamic monitoring in pregnancy to guide treatment of hypertension significantly reduces the rate of severe hypertension and allows identification of high-resistance, low-output hypertensive pregnancies that are associated with an increased rate of fetal growth restriction. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Examinar si el tratamiento para la hipertensión en el embarazo guiado por un seguimiento en serie de las principales constantes hemodinámicas de la madre conduce a una reducción en la tasa de hipertensión grave, definida como presión arterial ≥ 160/110 mmHg; y evaluar los diferentes perfiles hemodinámicos longitudinales asociados a la monoterapia con beta-bloqueantes, la monoterapia con vasodilatadores y la terapia dual, y su relación con los resultados, como la restricción del crecimiento fetal. MÉTODOS: Se realizó un estudio observacional prospectivo en una clínica especializada en hipertensión prenatal de un hospital de atención terciaria del Reino Unido. Se reclutaron consecutivamente a cincuenta y dos mujeres no tratadas que presentaban hipertensión y se comenzó a tratarlas, bien con un beta-bloqueante o bien con un vasodilatador. La elección del agente antihipertensivo inicial se determinó de acuerdo con un modelo elaborado previamente para predecir la respuesta al beta-bloqueante labetalol en mujeres embarazadas que necesitaban tratamiento antihipertensivo. Al inicio se registraron las características demográficas y las variables hemodinámicas maternas asociadas con una respuesta terapéutica al labetalol, definida como un control de la presión arterial < 140/90 mmHg con monoterapia de labetalol durante todo el embarazo que se analizó mediante regresión logística para crear un modelo con el que pronosticar un control sostenido de la presión arterial, como se describe arriba. Las mujeres fueron sometidas a revisiones regulares hasta el momento del parto y se les hizo un seguimiento hemodinámico en serie durante todo el embarazo. Si la presión arterial era elevada, se empleó de nuevo el modelo de predicción para determinar si se debería añadir un tratamiento antihipertensivo alternativo, ya sea con un beta-bloqueante adicional o con un vasodilatador. El tratamiento que tuvo en cuenta los resultados del seguimiento hemodinámico en serie redujo la tasa de hipertensión prenatal grave del 18% al 3,8%. Al 77% de las mujeres se les recetó inicialmente un y al 23% un vasodilatador. El grupo que mantuvo un buen control de la presión arterial con monoterapia de beta-bloqueantes logró mejores resultados fetales y maternos. Este grupo tuvo menor presión arterial al inicio y durante toda la gestación, mostró un gasto cardíaco en buen estado y tuvo las tasas más bajas de restricción del crecimiento fetal. Los grupos que requirieron terapia dual para controlar su presión arterial mostraron persistentemente una mayor presión arterial y un mayor ritmo de restricción del crecimiento fetal. Los grupos que requirieron tratamiento vasodilatador debido a los altos niveles de resistencia vascular periférica, tanto al inicio como durante el embarazo, representaron el 81% de los casos con restricción del crecimiento fetal. CONCLUSIÓN: El uso de un seguimiento hemodinámico en serie en el embarazo como guía para el tratamiento de la hipertensión reduce significativamente la tasa de hipertensión severa y permite la identificación de embarazos con hipertensión de alta resistencia y malos resultados, asociados con una mayor tasa de restricción del crecimiento fetal. : (≥ 160/110 mmHg);β、,()。 : 。52、,β。β。,(<140/90 mmHg),logistic,。,。,(β)。 : ,18%3.8%。77%β,23%。β。,,。,。,81%。 : ,,、。. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
Rapacz-Leonard, A; Kankofer, M; Leonard, M; Wawrzykowski, J; Dąbrowska, M; Raś, A; Paździor-Czapula, K; Janowski, T
2015-10-01
In mammals, placenta separation at term may involve degradation of the extracellular matrix by matrix metalloproteinases (MMPs). The activity of MMPs is modulated by TIMPs. We hypothesized that the placentas of mares that deliver fetal membranes physiologically and those that retain fetal membranes (FMR) differ in terms of histology; mRNA expression of MMP-2 and MMP-9; protein expression of MMP-2, MMP-9, and TIMP-2; and the potential activity of both MMPs. Placenta biopsies were taken from mares (n = 9; 4 FMR, 5 controls) immediately after foal expulsion. Retention was defined as failure to expel all fetal membranes within 3 h of expulsion. All mares were monitored for time of expulsion. The degree of allantochorial/endometrial adhesion was determined in FMR mares, and biopsies from all mares were histologically examined. mRNA expression, protein immunolocalization, protein amount and potential enzyme activity were determined with RT-PCR, immunohistochemistry, Western Blotting and zymography, respectively. FMR mares had strong to extremely strong allantochorial/endometrial adhesion, and significantly more connective tissue in the allantochorial villi than controls. The range of MMP-2 mRNA expression levels was more than 13 times greater in FMR mares than in controls. Protein content of both MMPs and TIMP-2 differed significantly between groups. The range of potential MMP-2 and MMP-9 activity was larger in FMR mares, and MMP-2 potential activity was 1.4 times higher in controls (P = 0.02). These results indicate differences in extracellular matrix remodeling in FMR mares and controls, and suggest dysregulation of MMP expression and activation in FMR mares. Copyright © 2015 Elsevier Ltd. All rights reserved.
Thyroid-Stimulating Hormone Receptor Antibodies in Pregnancy: Clinical Relevance
Bucci, Ines; Giuliani, Cesidio; Napolitano, Giorgio
2017-01-01
Graves’ disease is the most common cause of thyrotoxicosis in women of childbearing age. Approximately 1% of pregnant women been treated before, or are being treated during pregnancy for Graves’ hyperthyroidism. In pregnancy, as in not pregnant state, thyroid-stimulating hormone (TSH) receptor (TSHR) antibodies (TRAbs) are the pathogenetic hallmark of Graves’ disease. TRAbs are heterogeneous for molecular and functional properties and are subdivided into activating (TSAbs), blocking (TBAbs), or neutral (N-TRAbs) depending on their effect on TSHR. The typical clinical features of Graves’ disease (goiter, hyperthyroidism, ophthalmopathy, dermopathy) occur when TSAbs predominate. Graves’ disease shows some peculiarities in pregnancy. The TRAbs disturb the maternal as well as the fetal thyroid function given their ability to cross the placental barrier. The pregnancy-related immunosuppression reduces the levels of TRAbs in most cases although they persist in women with active disease as well as in women who received definitive therapy (radioiodine or surgery) before pregnancy. Changes of functional properties from stimulating to blocking the TSHR could occur during gestation. Drug therapy is the treatment of choice for hyperthyroidism during gestation. Antithyroid drugs also cross the placenta and therefore decrease both the maternal and the fetal thyroid hormone production. The management of Graves’ disease in pregnancy should be aimed at maintaining euthyroidism in the mother as well as in the fetus. Maternal and fetal thyroid dysfunction (hyperthyroidism as well as hypothyroidism) are in fact associated with several morbidities. Monitoring of the maternal thyroid function, TRAbs measurement, and fetal surveillance are the mainstay for the management of Graves’ disease in pregnancy. This review summarizes the biochemical, immunological, and therapeutic aspects of Graves’ disease in pregnancy focusing on the role of the TRAbs in maternal and fetal function. PMID:28713331
Qayyum, Arslan; Arshad, Usman; Yousuf, Muhammad Rizwan; Ahmad, Nasim
2018-03-01
The aim of this study was to determine the effect of breeding method and season on pregnancy rate and cumulative embryonic and fetal losses in Nili-Ravi buffalo. Estrus detection was performed twice a day by teaser buffalo bull for 1 hour each. A 2 × 2 factorial design was used to address the breeding method and season. Buffaloes (n = 130) exhibiting estrus were randomly assigned to be bred either in peak breeding season (PBS; n = 80) or low breeding season (LBS; n = 50). Within each season, buffaloes were divided to receive either natural service (NS; n = 65) or artificial insemination (AI; n = 65). NS buffaloes, in estrus, were allowed to remain with the bull until mating. AI was achieved, using frozen thawed semen of bull of known fertility. PBS comprised of September to December and LBS were from May to July. Serial ultrasonography was performed on days 30, 45, 60, and 90 after breeding (day 0) to monitor pregnancy rate and embryonic and fetal losses. The pregnancy rate on day 30 after breeding was higher in NS as compared to AI group (63 vs. 43%; P < 0.05) during PBS while it did not differ (48 vs. 32%; P > 0.05) in LBS. The cumulative embryonic and fetal losses between days 31 and 90 were significantly lower in PBS than LBS (33 vs. 60%; P < 0.05), ignoring breeding method. Pregnancy rates were better with NS in PBS, and cumulative embryonic fetal losses were higher in LBS in Nili-Ravi buffalo.
Harris, E K; Berg, E P; Berg, E L; Vonnahme, K A
2013-02-01
Yorkshire gilts either remained in their individual stall from d 40 to term (CON; n = 7) or were subjected to exercise for 30 min 3 times per week from mid to late gestation (EX; n = 7) to determine the impact of increased maternal activity during gestation on maternal behavior, fetal growth, umbilical blood flow, and parturition. In parity 1, maternal body composition (10th rib back fat and LM area), maternal behavior, and farrowing characteristics were recorded. In parities 1 and 2, fetal growth, fetal heart rate, pulsatility index and resistance index, and umbilical blood flow were monitored beginning at d 39 of gestation continuing to d 81 of gestation. Exercise continued until d 104. Gilts allowed to exercise sat less (P < 0.01), stood more (P < 0.01), tended (P = 0.06) to lie down less, and had fewer postural changes (P < 0.01) compared with CON gilts. Umbilical blood flow increased (P < 0.01) in EX compared with CON gilts. Moreover, gilts had greater (P < 0.01) umbilical blood flow in their first parity compared with their second. Indices of vascular resistance were not affected (P ≥ 0.15) by maternal treatment; however, EX gilts reached peak pulsatility index earlier than CON gilts (56.2 vs. 64.3 ± 3.6 d). Fetal weights, piglet birth weights, placental weight, interval between piglet births, and blood lactate of newborn piglets were unaffected (P ≥ 0.15) by maternal treatment. Although maternal exercise during gestation in the pig increased umbilical blood flow and appeared to reduce maternal restlessness, impacts on offspring development in postnatal life are not known.
Tagliaferri, Salvatore; Esposito, Francesca Giovanna; Ippolito, Adelaide; Mereghini, Flavia; Magenes, Giovanni; Martinelli, Pasquale; Campanile, Marta; Signorini, Maria Gabriella
2017-03-01
The objective of this article is to provide an overview of the clinical experience of our telemedicine network (TOCOMAT) for fetal well-being assessment through computerized Cardiotocography (cCTG), analyzing cultural, socioeconomic, and environmental conditions of pregnant women and its economic sustainability over time. We used the central data store, including all cCTG records collected in Campania region (Italy) during 17 years of activity. The Operations Center acquires the traces recorded in the Remote Units and simultaneously performs a complex fetal heart rate analysis. An Internet or phone conference calling is available to discuss the information transmitted. Finally, the report is send back to the Remote Units. The number of cCTG traces performed was constantly increasing, despite the progressive reduction in the number of peripheral units involved. Pregnant women in Remote Unit group were younger and overweight and showed a higher incidence of diabetes and fetal defects than Operations Center ones. Moreover, a high rate of African migrant women and low socioeconomic and cultural standards were found in Remote Unit group. The cost analysis showed an economic advantage both in the reduction of inappropriate admissions and in the improvement of admission indicators (hospital stay days) for pregnant women. The global economic recession has had a significant impact on the Italian regional healthcare system and socioeconomic deprivation. Telemedicine could avoid unnecessary referral to Level III centers (Hospital) in Campania region, where the average population density is very high, allowing equal access to ultra-specialist assessment irrespective of the geographical location of the pregnant woman with medium to high risk, as well as rationalizing the costs for maternal and fetal care.
Millar, Kathryn; Patel, Suha; Munson, Meghan; Vesel, Linda; Subbiah, Shalini; Jones, Rachel M; Little, Sarah; Papageorghiou, Aris T; Villar, Jose; Wegner, Mary Nell; Pearson, Nick; Muigai, Faith; Ongeti, Catherine; Langer, Ana
2018-06-22
The burden of preterm birth, fetal growth impairment, and associated neonatal deaths disproportionately falls on low- and middle-income countries where modern obstetric tools are not available to date pregnancies and monitor fetal growth accurately. The INTERGROWTH-21 st gestational dating, fetal growth monitoring, and newborn size at birth standards make this possible. To scale up the INTERGROWTH-21 st standards, it is essential to assess the feasibility and acceptability of their implementation and their effect on clinical decision-making in a low-resource clinical setting. This study protocol describes a pre-post, quasi-experimental implementation study of the standards at Jacaranda Health, a maternity hospital in peri-urban Nairobi, Kenya. All women with viable fetuses receiving antenatal and delivery services, their resulting newborns, and the clinicians caring for them from March 2016 to March 2018 are included. The study comprises a 12-month preimplementation phase, a 12-month implementation phase, and a 5-month post-implementation phase to be completed in August 2018. Quantitative clinical and qualitative data collected during the preimplementation and implementation phases will be assessed. A clinician survey was administered eight months into the implementation phase, month 20 of the study. Implementation outcomes include quantitative and qualitative analyses of feasibility, acceptability, adoption, appropriateness, fidelity, and penetration of the standards. Clinical outcomes include appropriateness of referral and effect of the standards on clinical care and decision-making. Descriptive analyses will be conducted, and comparisons will be made between pre- and postimplementation outcomes. Qualitative data will be analyzed using thematic coding and compared across time. The study was approved by the Amref Ethics and Scientific Review Committee (Kenya) and the Harvard University Institutional Review Board. Study results will be shared with stakeholders through conferences, seminars, publications, and knowledge management platforms. From October 2016 to February 2017, over 90% of all full-time Jacaranda clinicians (26/28) received at least one of the three aspects of the INTERGROWTH-21 st training: gestational dating ultrasound, fetal growth monitoring ultrasound, and neonatal anthropometry standards. Following the training, implementation and evaluation of the standards in Jacaranda Health's clinical workflow will take place from March 2017 through March 5, 2018. Data analysis will be finalized, and results will be shared by August 2018. The findings of this study will have major implications on the national and global scale up of the INTERGROWTH-21 st standards and on the process of scaling up global standards in general, particularly in limited-resource settings. RR1-10.2196/10293. ©Kathryn Millar, Suha Patel, Meghan Munson, Linda Vesel, Shalini Subbiah, Rachel M. Jones, Sarah Little, Aris T. Papageorghiou, Jose Villar, Mary Nell Wegner, Nick Pearson, Faith Muigai, Catherine Ongeti, Ana Langer. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 22.06.2018.
Villar, José; Cheikh Ismail, Leila; Staines Urias, Eleonora; Giuliani, Francesca; Ohuma, Eric O; Victora, Cesar G; Papageorghiou, Aris T; Altman, Douglas G; Garza, Cutberto; Barros, Fernando C; Puglia, Fabien; Ochieng, Roseline; Jaffer, Yasmin A; Noble, Julia A; Bertino, Enrico; Purwar, Manorama; Pang, Ruyan; Lambert, Ann; Chumlea, Cameron; Stein, Alan; Fernandes, Michelle; Bhutta, Zulfiqar A; Kennedy, Stephen H
2018-02-01
The World Health Organization recommends that human growth should be monitored with the use of international standards. However, in obstetric practice, we continue to monitor fetal growth using numerous local charts or equations that are based on different populations for each body structure. Consistent with World Health Organization recommendations, the INTERGROWTH-21 st Project has produced the first set of international standards to date pregnancies; to monitor fetal growth, estimated fetal weight, Doppler measures, and brain structures; to measure uterine growth, maternal nutrition, newborn infant size, and body composition; and to assess the postnatal growth of preterm babies. All these standards are based on the same healthy pregnancy cohort. Recognizing the importance of demonstrating that, postnatally, this cohort still adhered to the World Health Organization prescriptive approach, we followed their growth and development to the key milestone of 2 years of age. The purpose of this study was to determine whether the babies in the INTERGROWTH-21 st Project maintained optimal growth and development in childhood. In the Infant Follow-up Study of the INTERGROWTH-21 st Project, we evaluated postnatal growth, nutrition, morbidity, and motor development up to 2 years of age in the children who contributed data to the construction of the international fetal growth, newborn infant size and body composition at birth, and preterm postnatal growth standards. Clinical care, feeding practices, anthropometric measures, and assessment of morbidity were standardized across study sites and documented at 1 and 2 years of age. Weight, length, and head circumference age- and sex-specific z-scores and percentiles and motor development milestones were estimated with the use of the World Health Organization Child Growth Standards and World Health Organization milestone distributions, respectively. For the preterm infants, corrected age was used. Variance components analysis was used to estimate the percentage variability among individuals within a study site compared with that among study sites. There were 3711 eligible singleton live births; 3042 children (82%) were evaluated at 2 years of age. There were no substantive differences between the included group and the lost-to-follow up group. Infant mortality rate was 3 per 1000; neonatal mortality rate was 1.6 per 1000. At the 2-year visit, the children included in the INTERGROWTH-21 st Fetal Growth Standards were at the 49th percentile for length, 50th percentile for head circumference, and 58th percentile for weight of the World Health Organization Child Growth Standards. Similar results were seen for the preterm subgroup that was included in the INTERGROWTH-21 st Preterm Postnatal Growth Standards. The cohort overlapped between the 3rd and 97th percentiles of the World Health Organization motor development milestones. We estimated that the variance among study sites explains only 5.5% of the total variability in the length of the children between birth and 2 years of age, although the variance among individuals within a study site explains 42.9% (ie, 8 times the amount explained by the variation among sites). An increase of 8.9 cm in adult height over mean parental height is estimated to occur in the cohort from low-middle income countries, provided that children continue to have adequate health, environmental, and nutritional conditions. The cohort enrolled in the INTERGROWTH-21 st standards remained healthy with adequate growth and motor development up to 2 years of age, which supports its appropriateness for the construction of international fetal and preterm postnatal growth standards. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.
Rei, Mariana; Tavares, Sara; Pinto, Pedro; Machado, Ana P; Monteiro, Sofia; Costa, Antónia; Costa-Santos, Cristina; Bernardes, João; Ayres-De-Campos, Diogo
2016-10-01
Visual analysis of cardiotocographic (CTG) tracings has been shown to be prone to poor intra- and interobserver agreement when several interpretation guidelines are used, and this may have an important impact on the technology's performance. The aim of this study was to evaluate agreement in CTG interpretation using the new 2015 FIGO guidelines on intrapartum fetal monitoring. A pre-existing database of intrapartum CTG tracings was used to sequentially select 151 cases acquired with a fetal electrode, with duration exceeding 60minutes, and signal loss less than 15%. These tracings were presented to six clinicians, three with more than 5 years' experience in the labor ward, and three with 5 or less years' experience. Observers were asked to evaluate tracings independently, to assess basic CTG features: baseline, variability, accelerations, decelerations, sinusoidal pattern, tachysystole, and to classify each tracing as normal, suspicious or pathologic, according to the 2015 FIGO guidelines on intrapartum fetal monitoring. Agreement between observers was evaluated using the proportions of agreement (Pa), with 95% confidence intervals (95%CI). A good interobserver agreement was found in the evaluation of most CTG features, but not bradycardia, reduced variability, saltatory pattern, absence of accelerations and absence of decelerations. For baseline classification Pa was 0.85 [0.82-0.90], for variability 0.82 [0.78-0.85], for accelerations 0.72 [0.68-0.75], for tachysystole 0.77 [0.74-0.81], for decelerations 0.92 [0.90-0.95], for variable decelerations 0.62 [0.58-0.65], for late decelerations 0.63 [0.59-0.66], for repetitive decelerations 0.73 [0.69-0.78], and for prolonged decelerations 0.81 [0.77-0.85]. For overall CTG classification, Pa were 0.60 [0.56-0.64], for classification as normal 0.67 [0.61-0.72], for suspicious 0.54 [0.48-0.60] and for pathologic 0.59 [0.51-0.66]. No differences in agreement according to the level of expertise were observed, except in the identification of accelerations, where it was better in the more experienced group. A good interobserver agreement was found in evaluation of most CTG features and in overall tracing classification. Results were better than those reported in previous studies evaluating agreement in overall tracing classification. Observer experience did not appear to play a role in agreement. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Ethnic analogies and differences in fetal heart rate variability signal: A retrospective study.
Tagliaferri, Salvatore; Esposito, Francesca Giovanna; Fagioli, Rosa; Di Cresce, Marco; Sacchi, Lucia; Signorini, Maria Gabriella; Campanile, Marta; Martinelli, Pasquale; Magenes, Giovanni
2017-02-01
We aimed to analyze computerized cardiotocographic (cCTG) parameters (including fetal heart rate baseline, short-term variability, Delta, long-term irregularity [LTI], interval index [II], low frequency [LF], movement frequency [MF], high frequency [HF], and approximate entropy [ApEn]) in physiological term pregnancies in order to correlate them with ethnic differences. The clinical meaning of numerical parameters may explain physiological or paraphysiological phenomena that occur in fetuses of different ethnic origins. A total of 696 pregnant women, including 384 from Europe, 246 from sub-Saharan Africa, 45 from South-East Asia, and 21 from South America, were monitored from the 37th to the 41st week of gestation. Statistical analysis was performed with the analysis of variance test, Pearson correlation test and receiver-operator curves (P < 0.05). Our results showed statistically significant differences (P < 0.05) between white and black women for Delta, LTI, LF, MF, HF, and ApEn; between white and Asian women for Delta, LTI, MF, and the LF/(HF + MF) ratio; and between white and Latina women for Delta, LTI, and ApEn. In particular, Delta and LTI performed better in the white group than in the black, Asian, and Latina groups. Instead, LF, MF, HF, and ApEn performed better in the black than in the white group. Our results confirmed the integrity and normal functionality of both central and autonomic nervous system components for all fetuses investigated. Therefore, CTG monitoring should include both linear and nonlinear components of fetal heart rate variability in order to avoid misinterpretations of the CTG trace among ethnic groups. © 2016 Japan Society of Obstetrics and Gynecology.
The Belgian, French and Dutch midwife on trial: A critical case study.
Eggermont, Marlies
2015-05-01
to develop juridical recommendations in order to avoid midwifery medical liability when providing intrapartum care. case law of the past 40 years concerning midwifery medical negligence when assisting labour/delivery in a hospital was analysed. Databases used were Jura and Judit (Belgium), Legifrance, Juricaf and Dalloz (France) and Recht, Rechtspraak (The Netherlands). A minority of cases were retrieved through contacts with insurance companies (only Belgium), lawyers and courts. law suits in Belgium, France and The Netherlands. the 100 analysed cases could be categorised into four types. The judicial assessment was focused on three domains of expertise of the midwife. Most cases involved interpreting fetal monitoring (47%), followed by recognising a specific pathology (32%) and responding to a complication (12%). A fourth type of case concerned exceeding the boundaries of the legal competencies of the midwife (9%). not identifying fetal distress through fetal monitoring was the most common cause of midwifery liability (15/47), followed by not recognising the symptoms of a pathology (10/32), particularly placental abruption and uterine rupture. Also an inaccurate response to complications (3/12) and evidently exceeding the professional competencies involved midwifery liability. achieving cardiotocograph interpretation skills is the first and most important recommendation. In pathologic cases, the midwife should immediately refer to an obstetrician, without any hesitation. The third recommendation is working in a team with the obstetrician. If the midwife has reasonable (evidence-based) doubts about the practice of the obstetrician, she should insist on re-assessment with respect to the boundaries of her competencies. The fourth recommendation concerns practising with knowledge of the client׳s/patient׳s medical record and updating the record with performances and observations. Consciously choosing the type of medical intervention in urgent cases of pathology is the final recommendation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Bertsias, G K; Agmon-Levin, N; Brown, S; Cervera, R; Costedoat-Chalumeau, N; Doria, A; Fischer-Betz, R; Forger, F; Moraes-Fontes, M F; Khamashta, M; King, J; Lojacono, A; Marchiori, F; Meroni, P L; Mosca, M; Motta, M; Ostensen, M; Pamfil, C; Raio, L; Schneider, M; Svenungsson, E; Tektonidou, M; Yavuz, S; Boumpas, D; Tincani, A
2017-01-01
Objectives Develop recommendations for women's health issues and family planning in systemic lupus erythematosus (SLE) and/or antiphospholipid syndrome (APS). Methods Systematic review of evidence followed by modified Delphi method to compile questions, elicit expert opinions and reach consensus. Results Family planning should be discussed as early as possible after diagnosis. Most women can have successful pregnancies and measures can be taken to reduce the risks of adverse maternal or fetal outcomes. Risk stratification includes disease activity, autoantibody profile, previous vascular and pregnancy morbidity, hypertension and the use of drugs (emphasis on benefits from hydroxychloroquine and antiplatelets/anticoagulants). Hormonal contraception and menopause replacement therapy can be used in patients with stable/inactive disease and low risk of thrombosis. Fertility preservation with gonadotropin-releasing hormone analogues should be considered prior to the use of alkylating agents. Assisted reproduction techniques can be safely used in patients with stable/inactive disease; patients with positive antiphospholipid antibodies/APS should receive anticoagulation and/or low-dose aspirin. Assessment of disease activity, renal function and serological markers is important for diagnosing disease flares and monitoring for obstetrical adverse outcomes. Fetal monitoring includes Doppler ultrasonography and fetal biometry, particularly in the third trimester, to screen for placental insufficiency and small for gestational age fetuses. Screening for gynaecological malignancies is similar to the general population, with increased vigilance for cervical premalignant lesions if exposed to immunosuppressive drugs. Human papillomavirus immunisation can be used in women with stable/inactive disease. Conclusions Recommendations for women's health issues in SLE and/or APS were developed using an evidence-based approach followed by expert consensus. PMID:27457513
[Nursing practice in maternity intensive care units. Severe pre-eclampsia in a primigravida].
Carmona-Guirado, A J; Escaño-Cardona, V; García-Cañedo, F J
2015-01-01
39 year old woman, pregnant for 31+5 weeks, who came to our intensive care unit (ICU) referred from the emergency department of the hospital, having swollen ankles, headache and fatigue at moderate effort. We proceeded to take blood pressure (158/96 mmHg) and assess lower limb edema. The fetal heart rate monitoring was normal. Knowledgeable and user of healthy guidelines during her pregnancy, she did not follow any treatment. Single mother, she worried about her fetus (achieved through in vitro fertilization), her mother offered to help for any mishap. We developed an Individualized Care Plan. For data collection we used: Rating 14 Virginia Henderson Needs and diagnostic taxonomy NANDA, NOC, NIC. Nursing diagnoses of "fluid volume excess" and "risk of impaired maternal-fetal dyad" were detected, as well as potential complications such as eclampsia and fetal prematurity. Our overall objectives (NOC) were to integrate the woman in the process she faced and that she knew how to recognize the risk factors inherent in her illness. Nursing interventions (NIC) contemplated the awareness and treatment of her illness and the creation of new healthy habits. The work of nursing Maternal ICU allowed women to help maintain maximum maternal and fetal well-being by satisfying any of her needs. Mishandling of the situation leads into a framework of high morbidity and mortality in our units. Copyright © 2014 Elsevier España, S.L.U. y SEEIUC. All rights reserved.
Maternal positioning affects fetal heart rate changes after epidural analgesia for labour.
Preston, R; Crosby, E T; Kotarba, D; Dudas, H; Elliott, R D
1993-12-01
Adverse fetal heart rate (FHR) changes suggestive of fetal hypoxia are seen in patients with normal term pregnancies after initiation of epidural block for labour analgesia. It was our hypothesis that, in some parturients, these changes were a consequence of concealed aortocaval compression resulting in decreased uterine blood flow. We expected that the full lateral position compared with the wedged supine position would provide more effective prophylaxis against aortocaval compression. To test our hypothesis we studied the role of maternal positioning on FHR changes during onset of epidural analgesia for labour. Eighty-eight ASA Class I or II term parturients were randomized into two groups: those to be nursed in the wedged supine position and those to be nursed in the full lateral position during induction of an epidural block. External FHR monitoring was employed to assess the fetal response to initiation of labour epidural analgesia. Epidural catheters were sited with the parturients in the sitting position and the patients then assumed the study position. After a negative test dose, a standardized regimen of bupivacaine 0.25% was employed to provide labour analgesia. The quality and efficacy of the block were assessed using VAS pain scores, motor block scores and sensory levels. The results demonstrated that there was no difference in the quality of analgesia provided nor in the incidence of asymmetric blocks. There was no difference in the observed incidence of FHR changes occurring during the initiation of the epidural block.(ABSTRACT TRUNCATED AT 250 WORDS)
Graves hyperthyroidism and pregnancy: a clinical update.
Patil-Sisodia, Komal; Mestman, Jorge H
2010-01-01
To provide a clinical update on Graves' hyperthyroidism and pregnancy with a focus on treatment with antithyroid drugs. We searched the English-language literature for studies published between 1929 and 2009 related to management of hyperthyroidism in pregnancy. In this review, we discuss differential diagnosis of hyperthyroidism, management, importance of early diagnosis, and importance of achieving proper control to avoid maternal and fetal complications. Diagnosing hyperthyroidism during pregnancy can be challenging because many of the signs and symptoms are similar to normal physiologic changes that occur in pregnancy. Patients with Graves disease require prompt treatment with antithyroid drugs and should undergo frequent monitoring for signs of fetal and maternal hyperthyroidism and hypothyroidism. Rates of maternal and perinatal complications are directly related to control of hyperthyroidism in the mother. Thyroid receptor antibodies should be assessed in all women with hyperthyroidism to help predict and reduce the risk of fetal or neonatal hyperthyroidism or hypothyroidism. The maternal thyroxine level should be kept in the upper third of the reference range or just above normal, using the lowest possible antithyroid drug dosage. Hyperthyroidism may recur in the postpartum period as Graves disease or postpartum thyroiditis; thus, it is prudent to evaluate thyroid function 6 weeks after delivery. Preconception counseling, a multidisciplinary approach to care, and patient education regarding potential maternal and fetal complications that can occur with different types of treatment are important. Preconception counseling and a multifaceted approach to care by the endocrinologist and the obstetric team are imperative for a successful pregnancy in women with Graves hyperthyroidism.
Fucharoen, Suthat; Inati, Adlette; Siritanaratku, Noppadol; Thein, Swee Lay; Wargin, William C.; Koussa, Suzanne; Taher, Ali; Chaneim, Nattawara; Boosalis, Michael; Berenson, Ronald; Perrine, Susan P.
2014-01-01
β–thalassemia intermedia syndromes (BTI) cause hemolytic anemia, ineffective erythropoiesis, and widespread complications. Higher fetal globin expression within genotypes reduces globin imbalance and ameliorates anemia. Sodium 2,2 dimethylbutyrate (HQK-1001), an orally bioavailable short-chain fatty acid derivative, induces γ-globin expression experimentally and is well-tolerated in normal subjects. Accordingly, a randomized, blinded, placebo-controlled, Phase I/II trial was performed in 21 adult BTI patients (14 with HbE/β0 thalassemia and 7 with β+/β0 thalassemia intermedia, to determine effective doses for fetal globin induction, safety, and tolerability. HQK-1001 or placebo were administered once daily for 8 weeks at four dose levels (10, 20, 30, or 40 mg/kg/day), and subjects were monitored for laboratory and clinical events. Pharmacokinetic profiles demonstrated a t1/2 of 10–12 hours. Adverse events with HQK-1001 treatment were not significantly different from placebo treatment. Median HbF increased with the 20 mg/kg treatment doses above baseline levels by 6.6% and 0.44 g/dL (p <0.01) in 8/9 subjects; total hemoglobin (Hgb) increased by a mean of 1.1 gm/dL in 4/9 subjects. These findings identify a safe oral therapeutic which induces fetal globin in BTI. Further investigation of HQK-1001 with longer dosing to definitively evaluate its hematologic potential appears warranted. PMID:23530969
Yoshida-Komiya, Hiromi; Goto, Aya; Yasumura, Seiji; Fujimori, Keiya; Abe, Masafumi
2015-01-01
The Fukushima Pregnancy and Birth Survey was launched to monitor pregnant mothers' health after the Great East Japan Earthquake and Fukushima Daiichi Nuclear Power Plant (NPP) accident. Several lines of investigations have indicated that a disaster impacts maternal mental health with childbirth. However, there is no research regarding mental health of mothers with fetal loss after a disaster. In this report, we focus on those women immediately after the Great East Japan Earthquake and Fukushima NPP accident and discuss their support needs. Data regarding 61 miscarriages, 5 abortions, and 22 stillbirths were analyzed among the women who were pregnant at the time of the accident in the present study. We used a two-item case-finding instrument for depression screening, and compared the childbirth group with the fetal loss groups. We also analyzed mothers' opinions written as free-form text. Among the three fetal loss groups, the proportion of positive depression screens was significantly higher in the miscarriage and stillbirth group than in the childbirth group. Mothers' opinions were grouped into six categories, with pregnancy-related items being most common, especially in the miscarriage and stillbirth groups. A higher proportion of Fukushima mothers with fetal loss, especially those with miscarriage and stillbirth, had depressive symptoms compared to those who experienced childbirth. Health care providers need to pay close attention to this vulnerable group and respond to their concerns regarding the effects on their fertility.
Anselem, Olivia; Tsatsaris, Vassilis; Lopez, Emmanuel; Krivine, Anne; Le Ray, Camille; Loulergue, Pierre; Floret, Daniel; Goffinet, Francois; Launay, Odile
2011-11-01
Because of insufficient vaccine coverage, there is an outbreak of measles since 2008 in France with an increasing incidence of cases, most of them among children less than 1 year old or young adults. When measles occurs during pregnancy, maternal and fetal morbidity is increased. Particularly pregnant women are exposed to a higher risk of severe respiratory distress that might cause death. Measles virus can be detected in the placenta. Placental infection appears to be involved in some cases of fetal death. The virus is not responsible for congenital defects but can induce histologic damages inside the placenta which may lead to fetal death. Major perinatal risks are also miscarriage and prematurity. When measles occurs in late pregnancy, congenital infection is possible with variable expression and a risk of subacute sclerosing panencephalitis. Non immune pregnant women or neonates exposed to measles should receive an immunoglobulin prophylaxis within 6 days after contact in order to reduce the risk of infection and severe morbidity. In case of declared measles infection, symptomatic treatment can be proposed and tocolysis can be used if preterm labor is associated. Daily fetal monitoring during the 14 days following the beginning of the eruption can be offered when the fetus is viable. Vaccination is recommended for the people born in France after 1980 with 2 doses of vaccine against measles, rubeola and mumps. Measles vaccine, an attenuated living vaccine, should not be administered during pregnancy but must be proposed before pregnancy or during the post-partum period. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Morén, Constanza; Hernández, Sandra; Guitart-Mampel, Mariona; Garrabou, Glòria
2014-09-22
Mitochondrial toxicity can be one of the most dreadful consequences of exposure to a wide range of external agents including pathogens, therapeutic agents, abuse drugs, toxic gases and other harmful chemical substances. However, little is known about the effects of mitochondrial toxicity on pregnant women exposed to these agents that may exert transplacental activity and condition fetal remodeling. It has been hypothesized that mitochondrial toxicity may be involved in some adverse obstetric outcomes. In the present study, we investigated the association between exposure to mitochondrial toxic agents and pathologic conditions ranging from fertility defects, detrimental fetal development and impaired newborn health due to intra-uterine exposure. We have reviewed data from studies in human subjects to propose mechanisms of mitochondrial toxicity that could be associated with the symptoms present in both exposed pregnant and fetal patients. Since some therapeutic interventions or accidental exposure cannot be avoided, further research is needed to gain insight into the molecular pathways leading to mitochondrial toxicity during pregnancy. The ultimate objective of these studies should be to reduce the mitochondrial toxicity of these agents and establish biomarkers for gestational monitoring of harmful effects.
Pregnancy and contraception in systemic and cutaneous lupus erythematosus.
Guettrot-Imbert, G; Morel, N; Le Guern, V; Plu-Bureau, G; Frances, C; Costedoat-Chalumeau, N
2016-10-01
A causal link has long been described between estrogen and systemic lupus erythematosus activity. Contraceptive and pregnancy management is now common for lupus patients, but pregnancy continues to be associated with higher maternal and fetal mortality/morbidity in systemic lupus erythematosus patients than among the general population. Potential complications include lupus flares, obstetric complications (fetal loss, in utero growth retardation, premature birth) and neonatal lupus syndrome. Association with antiphospholipid antibodies or antiphospholipid syndrome increases the risk of obstetric complications. Anti-SSA and/or anti-SSB antibodies put fetuses at risk for neonatal lupus. Improving the outcome of such pregnancies depends upon optimal systematic planning of pregnancy at a preconception counseling visit coupled with a multidisciplinary approach. Absence of lupus activity, use of appropriate medication during pregnancy based on the patient's medical history and risk factors, and regular monitoring constitute the best tools for achieving a favorable outcome in such high-risk pregnancies. The aim of this review is to provide an update on the management of contraception and pregnancy in systemic lupus erythematosus, cutaneous lupus and/or antiphospholipid syndrome in order to reduce the risk of complications and to ensure the best maternal and fetal prognosis. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Hemolytic disease of the fetus and newborn: managing the mother, fetus, and newborn.
Delaney, Meghan; Matthews, Dana C
2015-01-01
Hemolytic disease of the fetus and newborn (HDFN) affects 3/100 000 to 80/100 000 patients per year. It is due to maternal blood group antibodies that cause fetal red cell destruction and in some cases, marrow suppression. This process leads to fetal anemia, and in severe cases can progress to edema, ascites, heart failure, and death. Infants affected with HDFN can have hyperbilirubinemia in the acute phase and hyporegenerative anemia for weeks to months after birth. The diagnosis and management of pregnant women with HDFN is based on laboratory and radiographic monitoring. Fetuses with marked anemia may require intervention with intrauterine transfusion. HDFN due to RhD can be prevented by RhIg administration. Prevention for other causal blood group specificities is less studied. © 2015 by The American Society of Hematology. All rights reserved.
Prenatal development in fishers (Martes pennanti)
Frost, H.C.; Krohn, W.B.; Bezembluk, E.A.; Lott, R.; Wallace, C.R.
2005-01-01
We evaluated and quantified prenatal growth of fishers (Martes pennanti) using ultrasonography. Seven females gave birth to 21 kits. The first identifiable embryonic structures were seen 42 d prepartum; these appeared to be unimplanted blastocysts or gestational sacs, which subsequently implanted in the uterine horns. Maternal and fetal heart rates were monitored from first detection to birth. Maternal heart rates did not differ among sampling periods, while fetal hearts rates increased from first detection to birth. Head and body differentiation, visible limbs and skeletal ossification were visible by 30, 23 and 21 d prepartum, respectively. Mean diameter of gestational sacs and crown-rump lengths were linearly related to gestational age (P < 0.001). Biparietal and body diameters were also linearly related to gestational age (P < 0.001) and correctly predicted parturition dates within 1-2 d. ?? 2004 Elsevier Inc. All rights reserved.
Management of hypertension in pregnancy.
Chung, N A; Beevers, D G; Lip, G Y
2001-01-01
Hypertension is an important cause of both maternal and fetal morbidity and mortality in pregnant women. There are still no definitive guidelines as to when and how patients should be treated, but it is important that appropriate treatment is initiated early in patients at highest risk and they are closely monitored. Hypertension in pregnancy can be a difficult condition to diagnose and treat because of the numerous and differing classification systems that have been used in the past. One classification system, which accounts for the multisystem involvement which can occur in pre-eclampsia and eclampsia, divides hypertension in pregnancy into 3 main groups: pre-eclampsia, gestational hypertension and chronic hypertension. Little benefit to the fetus has been shown from treating gestational and chronic hypertension, but studies in this area have been small and would not have had the power to show a difference in outcome between treated and untreated groups. However, the reduction in morbidity and mortality in the treatment of pre-eclampsia is significant. Therefore, all pregnancies complicated by hypertension require monitoring to detect the possible onset of superimposed pre-eclampsia/eclampsia. Institutions should have a management strategy for those mothers with severe hypertension including a multidisciplinary approach, where the patient is to be monitored and which antihypertensive agents are to be used. It should not be forgotten that the definitive treatment for severe hypertension is delivery of the fetus despite risks to fetal morbidity and mortality. This will reduce blood pressure, but hypertension per se may still persist post partum requiring short term therapy.
Real-time monitoring of enzyme-free strand displacement cascades by colorimetric assays
NASA Astrophysics Data System (ADS)
Duan, Ruixue; Wang, Boya; Hong, Fan; Zhang, Tianchi; Jia, Yongmei; Huang, Jiayu; Hakeem, Abdul; Liu, Nannan; Lou, Xiaoding; Xia, Fan
2015-03-01
The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications.The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications. Electronic supplementary information (ESI) available: Experimental procedures and analytical data are provided. See DOI: 10.1039/c5nr00697j
Step 6: Does Not Routinely Employ Practices, Procedures Unsupported by Scientific Evidence
Goer, Henci; Sagady Leslie, Mayri; Romano, Amy
2007-01-01
Step 6 of the Ten Steps of Mother-Friendly Care addresses two issues: 1) the routine use of interventions (shaving, enemas, intravenous drips, withholding food and fluids, early rupture of membranes, and continuous electronic fetal monitoring; and 2) the optimal rates of induction, episiotomy, cesareans, and vaginal births after cesarean. Rationales for compliance and systematic reviews are presented. PMID:18523680
Assessment of the Noise Immune Stethoscope in a Clinical Environment
2014-03-01
compared to using a traditional stethoscope . Anecdotal feedback from the clinicians indicated that sounds from the heart and related cardiothoracic...same technology as widely available fetal heart rate monitors for the consumer market. Comparable to other devices that combine acoustic and Doppler...understand Doppler” Congestive heart failure “able to hear crackles” Aortic stenosis “similar to traditional stethoscope , able to hear flows across
Neurodevelopmental outcome of the late preterm infant.
Adams-Chapman, Ira
2006-12-01
There is very limited information about the developmental outcome of the late preterm infant. The developing brain is vulnerable to injury during this very active and important stage of fetal brain development; therefore, it is important to carefully monitor the neurologic outcome of these infants. This article discusses gestational brain development and complications of late preterm birth that contribute to the overall risk of brain injury.
Fuchs, Tomasz; Grobelak, Krzysztof; Pomorski, Michał; Zimmer, Mariusz
2016-01-01
Cardiotocography (CTG) is the most widely used procedure despite its low specificity for fetal acidosis and poor perinatal outcome. Fetal electrocardiography (fECG) with transabdominal electrodes is a new, non-invasive and promising method with greater potential for detecting impairment of fetal circulation. This study is the first that attempts to assess the usefulness of fECG in comparison to CTG during antepartum period. To determine if a single fECG examination along with CTG tracing and Doppler flow measurement in the fetal vessels has any additional clinical value in normal and intrauterine growth restricted (IUGR) fetuses. The study included 93 pregnancies with IUGR, 37 pregnancies with IUGR and brain sparing effect, and 324 healthy pregnant women. The T/QRS ratio, cerebro-placental ratio (CRP), and CTG tracings were analyzed. One-way analysis of variance and Spearman's rank correlation coefficient were applied. The relationship between results of the T/QRS ratio and CTG examination among the study groups was analyzed. The highest average mean value of the T/QRS ratio was recorded in the IUGR group with a normal CPR and a pathologic CTG (0.235 ± 0.014). The highest average maximum values were observed in the groups of IUGR pregnancies with a reduced CPR with normal (0.309 ± 0.100), suspicious (0.330 ± 0.102) and pathologic (0.319 ± 0.056) CTGs. Analysis of variance revealed differences between study groups regarding maximum values and the difference between maximum and minimal values of T/QRS. Correlations between groups were insignificant. Higher values of T/QRS ratio in IUGR pregnancies with normal and reduced CPR than in control group regardless of the result of CTG examination may indicate minimal worsening of intrauterine fetal well-being in growth retarded fetuses. No relationship between fECG examination and CTG tracings suggests that a single fECG does not provide any additional clinically significant information determining the condition of the fetus; however, further studies are required.
[Chronic hypertension and pregnancy].
Lecarpentier, Edouard; Tsatsaris, Vassili
2012-09-01
Hypertensive disorders in pregnancy are a leading cause of maternal and perinatal mortality and morbidity. The management of patients with chronic hypertension requires a multidisciplinary approach prior to conception, during pregnancy and post-partum. In the preconception period, fetotoxic agents should be discontinued. It is also essential to undertake a full cardiovascular examination which may, in some cases, question the possibility of pregnancy. During pregnancy, blood pressure should be monitored and controlled, but not necessarily returned to a normal value. Low blood pressure levels could indeed lead to placental hypoperfusion and fetal growth restriction. Close clinical, biological and ultrasound monitoring is recommended, even postpartum, since those patients are at higher risk for preeclampsia.
Green, C R; Mihic, A M; Brien, D C; Armstrong, I T; Nikkel, S M; Stade, B C; Rasmussen, C; Munoz, D P; Reynolds, J N
2009-03-01
Prenatal exposure to alcohol can result in a spectrum of adverse developmental outcomes, collectively termed fetal alcohol spectrum disorders (FASDs). This study evaluated deficits in sensory, motor and cognitive processing in children with FASD that can be identified using eye movement testing. Our study group was composed of 89 children aged 8-15 years with a diagnosis within the FASD spectrum [i.e. fetal alcohol syndrome (FAS), partial fetal alcohol syndrome (pFAS), and alcohol-related neurodevelopmental disorder (ARND)], and 92 controls. Subjects looked either towards (prosaccade) or away from (antisaccade) a peripheral target that appeared on a computer monitor, and eye movements were recorded with a mobile, video-based eye tracker. We hypothesized that: (i) differences in the magnitude of deficits in eye movement control exist across the three diagnostic subgroups; and (ii) children with FASD display a developmental delay in oculomotor control. Children with FASD had increased saccadic reaction times (SRTs), increased intra-subject variability in SRTs, and increased direction errors in both the prosaccade and antisaccade tasks. Although development was associated with improvements across tasks, children with FASD failed to achieve age-matched control levels of performance at any of the ages tested. Moreover, children with ARND had faster SRTs and made fewer direction errors in the antisaccade task than children with pFAS or FAS, although all subgroups were different from controls. Our results demonstrate that eye tracking can be used as an objective measure of brain injury in FASD, revealing behavioral deficits in all three diagnostic subgroups independent of facial dysmorphology.
Rosenfeld, Hila; Ornoy, Asher; Shechtman, Svetlana; Diav-Citrin, Orna
2009-01-01
AIMS Propylthiouracil (PTU) is presently considered to be the treatment of choice for hyperthyroidism in pregnancy. It is known to cross the human placenta, and therefore may affect the fetus. The major aims of this study were to evaluate the rate of major anomalies and to report the rate of fetal goitre, accompanied by hypothyroidism, in fetuses/ newborns of mothers after in utero exposure to PTU. METHODS Prospective observational controlled cohort study of PTU-exposed pregnancies of women counselled by the Israeli Teratology Information Service between the years 1994 and 2004 compared with women exposed to nonteratogens. RESULTS We followed up 115 PTU-exposed pregnancies and 1141 controls. The rate of major anomalies was comparable between the groups [PTU 1/80 (1.3%), control 34/1066 (3.2%), P= 0.507]. Hypothyroidism was found in 9.5% of fetuses/neonates (56.8% of whom with goitre). Hyperthyroidism, possibly resulting from maternal disease, was found in 10.3%. Goitres prenatally diagnosed by ultrasound were successfully treated in utero by maternal dose adjustment. In most cases neonatal thyroid functions normalized during the first month of life without any treatment. Median neonatal birth weight was lower [PTU 3145 g (2655–3537) vs. control 3300 g (2968–3600), P= 0.018]. CONCLUSIONS PTU does not seem to be a major human teratogen. However, it could cause fetal/neonatal hypothyroidism with or without goitre. Fetal thyroid size monitoring and neonatal thyroid function tests are important for appropriate prevention and treatment. PMID:19843064
YOSHIDA-KOMIYA, HIROMI; GOTO, AYA; YASUMURA, SEIJI; FUJIMORI, KEIYA; ABE, MASAFUMI; FOR THE PREGNANCY AND BIRTH SURVEY GROUP OF THE FUKUSHIMA HEALTH MANAGEMENT SURVEY
2015-01-01
ABSTRACT Background: The Fukushima Pregnancy and Birth Survey was launched to monitor pregnant mothers’ health after the Great East Japan Earthquake and Fukushima Daiichi Nuclear Power Plant (NPP) accident. Several lines of investigations have indicated that a disaster impacts maternal mental health with childbirth. However, there is no research regarding mental health of mothers with fetal loss after a disaster. In this report, we focus on those women immediately after the Great East Japan Earthquake and Fukushima NPP accident and discuss their support needs. Materials and Methods: Data regarding 61 miscarriages, 5 abortions, and 22 stillbirths were analyzed among the women who were pregnant at the time of the accident in the present study. We used a two-item case-finding instrument for depression screening, and compared the childbirth group with the fetal loss groups. We also analyzed mothers’ opinions written as free-form text. Results: Among the three fetal loss groups, the proportion of positive depression screens was significantly higher in the miscarriage and stillbirth group than in the childbirth group. Mothers’ opinions were grouped into six categories, with pregnancy-related items being most common, especially in the miscarriage and stillbirth groups. Conclusion: A higher proportion of Fukushima mothers with fetal loss, especially those with miscarriage and stillbirth, had depressive symptoms compared to those who experienced childbirth. Health care providers need to pay close attention to this vulnerable group and respond to their concerns regarding the effects on their fertility. PMID:26063510
A high- Tc SQUID-based sensor head cooled by a Joule-Thomson cryocooler
NASA Astrophysics Data System (ADS)
Rijpma, A. P.; ter Brake, H. J. M.; de Vries, E.; Nijhof, N.; Holland, H. J.; Rogalla, H.
2002-08-01
The goal of the so-called FHARMON project is to develop a high- Tc SQUID-based magnetometer system for the measurement of fetal heart activity in standard clinical environments. To lower the threshold for the application of this fetal heart monitor, it should be simple to operate. It is, therefore, advantageous to replace the liquid cryogen bath by a closed-cycle refrigerator. For this purpose, we selected a mixed-gas Joule-Thomson cooler; the APD Cryotiger ©. Because of its magnetic interference, the compressor of this closed-cycle cooler will be placed at a distance of ≈2 m from the actual sensor, which is an axial second order gradiometer. The gradiometer is formed by three magnetometers placed on an alumina cylinder, which is connected to the cold head of the cooler. This paper describes the sensor head in detail and reports on test experiments.
The choice of amniotic fluid in metabolomics for the monitoring of fetus health.
Palmas, Francesco; Fattuoni, Claudia; Noto, Antonio; Barberini, Luigi; Dessì, Angelica; Fanos, Vassilios
2016-01-01
Amniotic fluid (AF) is a biological fluid in which metabolite transport is regulated by the placenta, the permeable skin, fetal lung egress and gastric fluid. During pregnancy, the composition of AF changes from similar to the interstitial fluid of the mother, to a more complex system, influenced by the fetus's urine. Since AF reflects the mother's and the fetus's health status at the same time, it may be an important diagnostic tool for a wider spectrum of clinical conditions. Indeed, the metabolic characterization of AF in relation to pathological occurrences may lead to the discovery of new biomarkers for a better clinical practice. For this reason, metabolomics may be the most suitable strategy for this task. In this review, research works on metabolomic AF analysis are discussed according to the morbidity of interest, being preterm birth/labor, gestational age and diabetes and fetal malformations, along with a number of other important studies.
Fetal growth and perinatal outcome of pregnancies continuing after threatened abortion.
Das, A G; Gopalan, S; Dhaliwal, L K
1996-05-01
The present study was conducted with the aim to find out the effect of threatened abortion in the current pregnancy on the subsequent perinatal outcome and follow the growth pattern of the fetuses of such complicated pregnancies. The study group consisted of 55 women with threatened abortion and 55 women with normal pregnancies formed the control group. Most of the patients presented at 6-12 weeks' gestation. The fetal growth was monitored by both clinical as well as ultrasound (USG) parameters. The mean growth rates were almost identical throughout gestation. The mean values of each parameter of the study group were found lying with 95% confidence limit values of their control group. The apparent increased incidence of low lying placenta in early pregnancy probably contributed to threatened abortion. There was no significant difference in preterm delivery, low birth-weight and overall perinatal outcome.
1980-08-16
A retrospective study of 25,000 deliveries found that the outcome of pregnancy was suboptimal twice as frequently when a threatened abortion had occurred. The study from California showed the incidence of prematurity was increased as were those of low birth weight, breech delivery, and perinatal death when there was vaginal bleeding during gestation. 50-60% of those women admitted to hospital with threatened abortion aborted their pregnancy spontaneously. The study found no statistically significant increase in fetal congenital anomalies where the pregnancy had been complicated by vaginal bleeding in the first or second trimester. Other studies have suggested conflicting conclusions, but generally, threatened abortion indicates that a pregnancy is at risk. When the dates are uncertain the gestational age should be assessed by ultrasound. In the third trimester, the fetal wellbeing should be monitored by serial estimations of estrogen concentration, ultrasonography, and in selected cases, antenatal cardiotocography. Good antenatal care can minimize the effects of threatened abortion.
Neng, Jing; Li, Yina; Driscoll, Ashley J; Wilson, William C; Johnson, Patrick A
2018-06-06
A robust immunoassay based on surface-enhanced Raman scattering (SERS) has been developed to simultaneously detect trace quantities of multiple pathogenic antigens from West Nile virus, Rift Valley fever virus, and Yersinia pestis in fetal bovine serum. Antigens were detected by capture with silica-encapsulated nanotags and magnetic nanoparticles conjugated with polyclonal antibodies. The magnetic pull-down resulted in aggregation of the immune complexes, and the silica-encapsulated nanotags provided distinct spectra corresponding to each antigen captured. The limit of detection was ∼10 pg/mL in 20% fetal bovine serum, a significant improvement over previous studies in terms of sensitivity, level of multiplexing, and medium complexity. This highly sensitive multiplex immunoassay platform provides a promising method to detect various antigens directly in crude serum samples without the tedious process of sample preparation, which is desirable for on-site diagnostic testing and real-time disease monitoring.
1989-04-01
Development . Prenatal developmental stages are especially sensitive to environmental perturbations. At present, there is conflicting evidence of direct EM...effects on embryonic or fetal development . In addition, possible effects of the ELF system on parental behavior could also have an indirect effect on... development . The purpose of this element is to determine the incidence of abnormalities in embryonic development in tree swallows at treatment and control
Goldenberg, Robert L.; McClure, Elizabeth M.; Kodkany, Bhala; Wembodinga, Gilbert; Pasha, Omrana; Esamai, Fabian; Tshefu, Antoinette; Patel, Archana; Mabaye, Hillary; Goudar, Shivaparasad; Saleem, Sarah; Waikar, Manjushri; Langer, Ana; Bose, Carl L.; Rubens, Craig E.; Wright, Linda L.; Moore, Janet; Blanc, Ann
2013-01-01
Objective To determine the feasibility of introducing a simple indicator of quality of obstetric and neonatal care and to determine the proportion of potentially avoidable perinatal deaths in hospitals in low-income countries. Methods Between September 1, 2011, and February 29, 2012, data were collected from women who had a term pregnancy and were admitted to the labor ward of 1 of 6 hospitals in 4 low-income countries. Fetal heart tones on admission were monitored, and demographic and birth data were recorded. Results Data were obtained for 3555 women and 3593 neonates (including twins). The doptone was used on 97% of women admitted. The overall perinatal mortality rate was 34 deaths per 1000 deliveries. Of the perinatal deaths, 40%–45% occurred in the hospital and were potentially preventable by better hospital care. Conclusion The results demonstrated that it is possible to accurately determine fetal viability on admission via a doptone. Implementation of doptone use, coupled with a concise data record, might form the basis of a low-cost and sustainable program to monitor and evaluate efforts to improve quality of care and ultimately might to help to reduce the in-hospital component of perinatal mortality in low-income countries. PMID:23796259
Odendaal, H J; Hall, D R; Grové, D
2000-07-01
We set out to determine which patients admitted for expectant management of early onset severe pre-eclampsia develop abruptio placentae and to compare the perinatal mortality rate of patients who developed abruptio placentae with those who did not have this complication. This was a case controlled study, using gestational age at delivery to select a control group for 69 patients who developed abruptio placentae. The only significant difference on admission was the higher uric acid levels in patients who developed abruptio placentae. Mean admission to delivery intervals were 11.9 and 8.8 days for the control and abruption groups respectively (P = 0.0083). Fifty-eight per cent of the babies in the abruptio placentae group developed late decelerations, as determined by fetal heart rate monitoring compared with 32% in the control group. Lactate dehydrogenase levels before delivery were significantly higher in the abruption group, but it only became elevated shortly before delivery and in the minority of cases. There were two intrauterine and four neonatal deaths in the abruption group and two neonatal deaths in the control group. Late decelerations detected by frequent fetal heart rate monitoring in patients with early onset severe pre-eclampsia is the only early warning of abruptio placentae.
Ruano, Rodrigo; Klinkner, Denise B; Balakrishnan, Karthik; Novoa Y Novoa, Victoria A; Davies, Norman; Potter, Dean D; Carey, William A; Colby, Christopher E; Kolbe, Amy B; Arendt, Katherine W; Segura, Leal; Sviggum, Hans P; Lemens, Maureen A; Famuyide, Abimbola; Terzic, Andre
2018-05-15
To introduce the prenatal regenerative medicine service at Mayo Clinic for fetal endoscopic tracheal occlusion (FETO) care for severe congenital diaphragmatic hernia (CDH). Two cases of prenatal management of severe CDH with FETO between January and August 2017 are reported. Per protocol, FETO was offered for life-threatening severe CDH at between 26 and 29 weeks' gestation. Regenerative outcome end point was fetal lung growth. Gestational age at procedure and maternal and perinatal outcomes were additional monitored parameters. Diagnosis by ultrasonography of severe CDH was based on extremely reduced lung size (observed-to-expected lung area to head circumference ratio [o/e-LHR], eg, o/e-LHR of 20.3% for fetus 1 and 23.0% for fetus 2) along with greater than one-third of the liver herniated into the chest in both fetuses. Both patients underwent successful FETO at 28 weeks. At the time of intervention, no maternal or fetal complications were observed. Postintervention, fetal lung growth was observed in both fetuses, reaching an o/e-LHR of 62.7% at 36 weeks in fetus 1 and 52.4% at 32 weeks in fetus 2. The balloons were removed successfully at 35 weeks and 4 days by ultrasound-guided puncture in the first patient and at 32 weeks and 3 days by ex utero intrapartum therapy-to-airway procedure in the second patient. Postnatal management followed standard of care with patch CDH therapy. At discharge, one patient was breathing normally, whereas the other required minimal nasal cannula oxygen support. The successful launch of the first fetoscopic therapy for CDH at Mayo Clinic reveals its feasibility and safety, with early signs of benefit documented by fetal lung growth and reversal of severe pulmonary hypoplasia. clinicaltrials.gov Identifier: G170062. Copyright © 2018 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.
Spiroski, A M; Oliver, M H; Jaquiery, A L; Prickett, T C R; Espiner, E A; Harding, J E; Bloomfield, F H
2017-12-12
Fetal growth restriction increases the risk of fetal and neonatal mortality and morbidity, and contributes to increased risk of chronic disease later in life. Intra-amniotic insulin-like growth factor-1 (IGF1) treatment of the growth-restricted ovine fetus improves fetal growth, but postnatal effects are unknown. Here we report that intra-amniotic IGF1 treatment of the growth-restricted ovine fetus alters size at birth and mechanisms of early postnatal growth in a sex-specific manner. We also show that maternal plasma C-type natriuretic peptide (CNP) products are related to fetal oxygenation and size at birth, and hence may be useful for non-invasive monitoring of fetal growth restriction. Intrauterine IGF1 treatment in late gestation is a potentially clinically relevant intervention that may ameliorate the postnatal complications of fetal growth restriction. Placental insufficiency-mediated fetal growth restriction (FGR) is associated with altered postnatal growth and metabolism, which are, in turn, associated with increased risk of adult disease. Intra-amniotic insulin-like growth factor-1 (IGF1) treatment of ovine FGR increases growth rate in late gestation, but the effects on postnatal growth and metabolism are unknown. We investigated the effects of intra-amniotic IGF1 administration to ovine fetuses with uteroplacental embolisation-induced FGR on phenotypical and physiological characteristics in the 2 weeks after birth. We measured early postnatal growth velocity, amino-terminal propeptide of C-type natriuretic peptide (NTproCNP), body composition, tissue-specific mRNA expression, and milk intake in singleton lambs treated weekly with 360 μg intra-amniotic IGF1 (FGRI; n = 13 females, 19 males) or saline (FGRS; n = 18 females, 12 males) during gestation, and in controls (CON; n = 15 females, 22 males). There was a strong positive correlation between maternal NTproCNP and fetal oxygenation, and size at birth in FGR lambs. FGR lambs were ∼20% lighter at birth and demonstrated accelerated postnatal growth velocity. IGF1 treatment did not alter perinatal mortality, partially abrogated the reduction in newborn size in females, but not males, and reduced accelerated growth in both sexes. IGF1-mediated upregulation of somatotrophic genes in males during the early postnatal period could suggest that treatment effects are associated with delayed axis maturation, whilst treatment outcomes in females may rely on the reprogramming of nutrient-dependent mechanisms of growth. These data suggest that the growth-restricted fetus is responsive to intra-amniotic intervention with IGF1, and that sex-specific somatotrophic effects persist in the early postnatal period. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.
Non-invasive Fetal ECG Signal Quality Assessment for Multichannel Heart Rate Estimation.
Andreotti, Fernando; Graser, Felix; Malberg, Hagen; Zaunseder, Sebastian
2017-12-01
The noninvasive fetal ECG (NI-FECG) from abdominal recordings offers novel prospects for prenatal monitoring. However, NI-FECG signals are corrupted by various nonstationary noise sources, making the processing of abdominal recordings a challenging task. In this paper, we present an online approach that dynamically assess the quality of NI-FECG to improve fetal heart rate (FHR) estimation. Using a naive Bayes classifier, state-of-the-art and novel signal quality indices (SQIs), and an existing adaptive Kalman filter, FHR estimation was improved. For the purpose of training and validating the proposed methods, a large annotated private clinical dataset was used. The suggested classification scheme demonstrated an accuracy of Krippendorff's alpha in determining the overall quality of NI-FECG signals. The proposed Kalman filter outperformed alternative methods for FHR estimation achieving accuracy. The proposed algorithm was able to reliably reflect changes of signal quality and can be used in improving FHR estimation. NI-ECG signal quality estimation and multichannel information fusion are largely unexplored topics. Based on previous works, multichannel FHR estimation is a field that could strongly benefit from such methods. The developed SQI algorithms as well as resulting classifier were made available under a GNU GPL open-source license and contributed to the FECGSYN toolbox.
2013-01-01
Background Stillbirth classifications use various strategies to synthesise information associated with fetal demise with the aim of identifying key causes for the death. RECODE is a hierarchical classification of death-related conditions, which grants a major place to fetal growth restriction (FGR). Our objective was to explore how placement of FGR in the hierarchy affected results from the classification. Methods In the Rhône-Alpes region, all stillbirths were recorded in a local registry from 2000 to 2010 in three districts (N = 969). Small for gestational age (SGA) was defined as a birthweight below the 10th percentile. We applied RECODE and then modified the hierarchy, including FGR as the penultimate category (RECODE-R). Results 49.0% of stillbirths were SGA. From RECODE to RECODE-R, stillbirths attributable to FGR decreased from 38% to 14%, in favour of other related conditions. Nearly half of SGA stillbirths (49%) were reclassified. There was a non-significant tendency toward moderate SGA, singletons and full-term stillbirths to older mothers being reclassified. Conclusions The position of FGR in hierarchical stillbirth classification has a major impact on the first condition associated with stillbirth. RECODE-R calls less attention to monitoring SGA fetuses but illustrates the diversity of death-related conditions for small fetuses. PMID:24090495
Social variations in fetal growth in a Russian setting: an analysis of medical records.
Grjibovski, Andrej M; Bygren, Lars O; Svartbo, Boo; Magnus, Per
2003-10-01
The study examines variations in fetal growth by maternal social circumstances in a Russian town. All pregnant women registered at the antenatal clinics in 1999 in Severodvinsk (north-west Russia) and their live born infants comprised the study base (n=1399). Multivariate linear regression analysis was applied to quantify the effect of socio-demographic factors on birthweight and the ponderal index (PI). A clear gradient of birthweight in relation to mothers' education was revealed. Babies of the most educated mothers were 207 g (95% CI, 55, 358) heavier than babies of mothers with basic education. The average weight of those born to mothers with secondary and vocational levels of education was 172 g (95% CI, 91, 253) and 83 g (95% CI, 9, 163) lower compared with infants born to mothers with a university level of education after adjustment for age, parity, pre-pregnancy weight, marital status, maternal occupation, length of gestation, and sex of the baby. Maternal education also influenced the PI. Further studies should focus on the mechanisms of the coherence of maternal education and fetal growth. To ensure that all parts of the society benefit equally from economic and social reforms, social variations in pregnancy outcomes should be monitored during the time of transition.
Amin, Ruchi; Domack, Aaron; Bartoletti, Joseph; Peterson, Erika; Rink, Britton; Bruggink, Jennifer; Christensen, Melissa; Johnson, Anthony; Polzin, William; Wagner, Amy J
2018-05-23
Gastroschisis is an abdominal wall defect with increasing incidence. Given the lack of surveillance guidelines among maternal-fetal medicine (MFM) specialists, this study describes current practices in gastroschisis management. An online survey was administered to MFM specialists from institutions affiliated with the North American Fetal Therapy Network (NAFTNet). Questions focused on surveillance timing, testing, findings that changed clinical management, and delivery plan. Responses were obtained from 29/29 (100%) NAFTNet centers, comprising 143/371 (39%) providers. The majority had a regimen for antenatal surveillance in patients with stable gastroschisis (94%; 134/141). Antenatal testing began at 32 weeks for 68% (89/131) of MFM specialists. The nonstress test (55%; 72/129), biophysical profile (50%; 63/126), and amniotic fluid index (64%; 84/131) were used weekly. Estimated fetal weight (EFW) was performed monthly by 79% (103/131) of providers. At 28 weeks, abnormal EFW (77%; 97/126) and Doppler ultrasound (78%; 99/127) most frequently altered management. In stable gastroschisis, 43% (60/140) of providers delivered at 37 weeks, and 29% (40/ 140) at 39 weeks. Gastroschisis management differs among NAFTNet centers, although the majority initiate surveillance at 32 weeks. Timing of delivery still requires consensus. Prospective studies are necessary to further optimize practice guidelines and patient care. © 2018 S. Karger AG, Basel.
[Toxoplasmic infections in pregnancy: about 94 cases diagnosed at the Pasteur Institute of Tunis].
Siala, E; Ben Abdallah, R; Laouiti, F; Maatoug, R; Souissi, O; Aoun, K; Bouratbine, A
2014-05-01
The objectives of this study were to estimate the risk of maternal-fetal transmission of toxoplasmosis and its consequences on the fetus and to emphasize the importance of follow-up of newborns in Tunisia. It was a retrospective study of 94 cases of pergravidic toxoplasmic seroconversion who were diagnosed and followed in the Laboratory of Parasitology of Pasteur Institute of Tunis between 2005 and 2010. In our series, amniocentesis was performed for 60 parturients. Among the amniotic fluid tested, research of toxoplasmosis DNA by PCR was positive in 12 cases (12/60, 20 %). Twenty-six cases of congenital toxoplasmosis were diagnosed with 14 postnatal cases. The rate of maternal-fetal transmission of Toxoplasma gondii was 27.6 % (26/94). This risk increases with gestational age, from 19 % at seroconversion of the 1st quarter to 29.4 % in the 2nd quarter and 44.4 % in the 3rd trimester. Monitoring of newborns with congenital toxoplasmosis showed that only 3 children were symptomatic. There were 2 cases of toxoplasmic chorioretinitis and a case of brain damage. Under serological monitoring of newborns, 21 cases were lost to follow-up and monitoring was stopped for 29 after decrease of anti-toxoplasmic IgG. The prenatal diagnosis allowed to decrease the severe forms of congenital toxoplasmosis in Tunisia. Nevertheless, it is always necessary to raise the problem of the significant number of newborn children whose follow-up is incomplete. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Kaltner, H; Lips, K S; Reuter, G; Lippert, S; Sinowatz, F; Gabius, H J
1997-10-01
The display of cellular oligosaccharide chains is known to undergo marked developmental changes, as monitored histochemically with plant lectins. In conjunction with endogenous lectins respective ligand structures may have a functional role during fetal development. The assumption of a recognitive, functionally productive interplay prompts the study of the expression of a tissue lectin and of lectin-reactive glycoconjugates concomitantly. Focusing on common beta-galactosides as constituents of oligosaccharide chains and the predominant member of the family of galectins in mammals, namely galectin-1, the question therefore is addressed as to whether expression of lectin and lectin-reactive glycoconjugates exhibits alterations, assessed in three morphologically defined fetal stages and in adult bovine organs. Using a sandwich ELISA, the level of the rather ubiquitous galectin-1 is mostly increased in adult organs relative to respective fetal stages, except for the case of kidney. This developmental course is seen rather seldom, when the amounts of lectin-reactive glycoproteins or glycolipids are quantitated in solid-phase assays after tissue homogenization. Western blotting, combined with probing by labeled galectin-1, discloses primarily quantitative changes in the reactivity of individual glycoproteins. Performing the same assays on extract aliquots with a plant agglutinin, namely the galactoside-binding mistletoe lectin, whose fine specificity is different from galectin-1, its reduced extent of binding in solid-phase assays and the disparate profile of lectin-reactive glycoproteins reveal a non-uniform developmental alteration within the group of structural variants of beta-galactosides. Although sample preparation can affect ligand preservation and/or presentation and thus restricts the comparability of biochemical and histochemical results, especially for soluble reactants, the histochemical studies on frozen and paraffin-embedded sections of bovine heart, kidney and liver demonstrate that the localization of the galectin and of lectin-reactive epitopes can show a similar distribution, as seen in liver and heart, with organ-typical quantitative changes of a rather similar staining profile (heart, kidney) or notable changes in the spatial distribution (liver) in the course of development. This report emphasizes the potential value of combined monitoring of the lectin and its potential in vivo ligands to contribute to eventually unravel organ-related function(s) of a tissue lectin.
Sentilhes, Loïc; Sénat, Marie-Victoire; Boulogne, Anne-Isabelle; Deneux-Tharaux, Catherine; Fuchs, Florent; Legendre, Guillaume; Le Ray, Camille; Lopez, Emmanuel; Schmitz, Thomas; Lejeune-Saada, Véronique
2016-08-01
Shoulder dystocia (SD) is defined as a vaginal delivery in cephalic presentation that requires additional obstetric maneuvers to deliver the fetus after the head has delivered and gentle traction has failed. It complicates 0.5-1% of vaginal deliveries. Risks of brachial plexus birth injury (level of evidence [LE]3), clavicle and humeral fracture (LE3), perinatal asphyxia (LE2), hypoxic-ischemic encephalopathy (LE3) and perinatal mortality (LE2) increase with SD. Its main risk factors are previous SD and macrosomia, but both are poorly predictive; 50-70% of SD cases occur in their absence, and most deliveries when they are present do not result in SD. No study has proven that the correction of these risk factors (except gestational diabetes) would reduce the risk of SD. Physical activity is recommended before and during pregnancy to reduce the occurrence of some risk factors for SD (Grade C). In obese women, physical activity should be coupled with dietary measures to reduce fetal macrosomia and weight gain during pregnancy (Grade A). Women with gestational diabetes require diabetes care (diabetic diet, glucose monitoring, insulin if needed) (Grade A) because it reduces the risk of macrosomia and SD (LE1). Only two measures are proposed for avoiding SD and its complications. First, induction of labor is recommended in cases of impending macrosomia if the cervix is favorable at a gestational age of 39 weeks or more (professional consensus). Second, cesarean delivery is recommended before labor in three situations and during labor in one: (i) estimated fetal weight (EFW) >4500g if associated with maternal diabetes (Grade C), (ii) EFW >5000g in women without diabetes (Grade C), (iii) history of SD associated with severe neonatal or maternal complications (professional consensus), and finally during labor, (iv) in case of fetal macrosomia and failure to progress in the second stage, when the fetal head station is above +2 (Grade C). In cases of SD, it is recommended to avoid the following actions: excessive traction on the fetal head (Grade C), fundal pressure (Grade C), and inverse rotation of the fetal head (professional consensus). The McRoberts maneuver, with or without suprapubic pressure, is recommended first (Grade C). If it fails and the posterior shoulder is engaged, Wood's maneuver should be performed preferentially; if the posterior shoulder is not engaged, it is preferable to attempt to deliver the posterior arm next (professional consensus). It appears necessary to know at least two maneuvers to perform should the McRoberts maneuver fail (professional consensus). A pediatrician should be immediately informed of SD. The initial clinical examination should check for complications, such as brachial plexus injury or clavicle fracture (professional consensus). If no complications are observed, neonatal monitoring need not be modified (professional consensus). The implementation of practical training with simulation for all care providers in the delivery room is associated with a significant reduction in neonatal (LE3) but not maternal (LE3) injury. SD remains an unpredictable obstetric emergency. All physicians and midwives should know and perform obstetric maneuvers if needed, quickly but calmly. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Fetal growth: a review of terms, concepts and issues relevant to obstetrics.
Mayer, C; Joseph, K S
2013-02-01
The perinatal literature includes several potentially confusing and controversial terms and concepts related to fetal size and growth. This article discusses fetal growth from an obstetric perspective and addresses various issues including the physiologic mechanisms that determine fetal growth trajectories, known risk factors for abnormal fetal growth, diagnostic and prognostic issues related to restricted and excessive growth and temporal trends in fetal growth. Also addressed are distinctions between fetal growth 'standards' and fetal growth 'references', and between fetal growth charts based on estimated fetal weight vs those based on birth weight. Other concepts discussed include the incidence of fetal growth restriction in pregnancy (does the frequency of fetal growth restriction increase or decrease with increasing gestation?), the obstetric implications of studies showing associations between fetal growth and adult chronic illnesses (such as coronary heart disease) and the need for customizing fetal growth standards. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.
High-throughput cell analysis and sorting technologies for clinical diagnostics and therapeutics
NASA Astrophysics Data System (ADS)
Leary, James F.; Reece, Lisa M.; Szaniszlo, Peter; Prow, Tarl W.; Wang, Nan
2001-05-01
A number of theoretical and practical limits of high-speed flow cytometry/cell sorting are important for clinical diagnostics and therapeutics. Three applications include: (1) stem cell isolation with tumor purging for minimal residual disease monitoring and treatment, (2) identification and isolation of human fetal cells from maternal blood for prenatal diagnostics and in-vitro therapeutics, and (3) high-speed library screening for recombinant vaccine production against unknown pathogens.
Achieving Strong Teamwork Practices in Hospital Labor and Delivery Units
2010-01-01
measures Maternal deaths 750 Uterine rupture 100 Unplanned maternal admission to ICU 65 Return to OR/L&D 40 3rd- or 4th-degree perineal laceration 5 Maternal...maternal lacerations ) Site 5 Improvement in communication due to team huddles/briefs at morning shift change None reported Debriefs have matured...practices, including a review of oxy- tocin use, use of standardized protocols, an exam for electronic fetal monitoring, and lowering surgical-site
Real-time monitoring of enzyme-free strand displacement cascades by colorimetric assays.
Duan, Ruixue; Wang, Boya; Hong, Fan; Zhang, Tianchi; Jia, Yongmei; Huang, Jiayu; Hakeem, Abdul; Liu, Nannan; Lou, Xiaoding; Xia, Fan
2015-03-19
The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications.
Ethics of fetal tissue transplantation.
Sanders, L M; Giudice, L; Raffin, T A
1993-01-01
Now that the Clinton Administration has overturned the ban on federal funding for fetal tissue transplantation, old ethical issues renew their relevance and new ethical issues arise. Is fetal tissue transplantation necessary and beneficial? Are fetal rights violated by the use of fetal tissue in research? Is there a moral danger that the potential of fetal tissue donation will encourage elective abortions? Should pregnant women be allowed to designate specific fetal transplant recipients? What criteria should be used to select fetal tissue transplants? Whose consent should be required for the use of fetal tissue for transplantation? We review the current state of clinical research with fetal tissue transplantation, the legal history of fetal tissue research, the major arguments against the use of fetal tissue for transplantation, and the new postmoratorium ethical dilemmas. We include recommendations for guidelines to govern the medical treatment of fetal tissue in transplantation. Images PMID:8236984
Andreoli, L; Bertsias, G K; Agmon-Levin, N; Brown, S; Cervera, R; Costedoat-Chalumeau, N; Doria, A; Fischer-Betz, R; Forger, F; Moraes-Fontes, M F; Khamashta, M; King, J; Lojacono, A; Marchiori, F; Meroni, P L; Mosca, M; Motta, M; Ostensen, M; Pamfil, C; Raio, L; Schneider, M; Svenungsson, E; Tektonidou, M; Yavuz, S; Boumpas, D; Tincani, A
2017-03-01
Develop recommendations for women's health issues and family planning in systemic lupus erythematosus (SLE) and/or antiphospholipid syndrome (APS). Systematic review of evidence followed by modified Delphi method to compile questions, elicit expert opinions and reach consensus. Family planning should be discussed as early as possible after diagnosis. Most women can have successful pregnancies and measures can be taken to reduce the risks of adverse maternal or fetal outcomes. Risk stratification includes disease activity, autoantibody profile, previous vascular and pregnancy morbidity, hypertension and the use of drugs (emphasis on benefits from hydroxychloroquine and antiplatelets/anticoagulants). Hormonal contraception and menopause replacement therapy can be used in patients with stable/inactive disease and low risk of thrombosis. Fertility preservation with gonadotropin-releasing hormone analogues should be considered prior to the use of alkylating agents. Assisted reproduction techniques can be safely used in patients with stable/inactive disease; patients with positive antiphospholipid antibodies/APS should receive anticoagulation and/or low-dose aspirin. Assessment of disease activity, renal function and serological markers is important for diagnosing disease flares and monitoring for obstetrical adverse outcomes. Fetal monitoring includes Doppler ultrasonography and fetal biometry, particularly in the third trimester, to screen for placental insufficiency and small for gestational age fetuses. Screening for gynaecological malignancies is similar to the general population, with increased vigilance for cervical premalignant lesions if exposed to immunosuppressive drugs. Human papillomavirus immunisation can be used in women with stable/inactive disease. Recommendations for women's health issues in SLE and/or APS were developed using an evidence-based approach followed by expert consensus. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Intravenous ferric carboxymaltose for anaemia in pregnancy.
Froessler, Bernd; Collingwood, Joshua; Hodyl, Nicolette A; Dekker, Gustaaf
2014-03-25
Iron deficiency is a common nutritional deficiency amongst women of childbearing age. Peri-partum iron deficiency anaemia (IDA) is associated with significant maternal, fetal and infant morbidity. Current options for treatment are limited: these include oral iron supplementation, which can be ineffective and poorly tolerated, and red blood cell transfusions, which carry an inherent risk and should be avoided. Ferric carboxymaltose is a new treatment option that may be better tolerated.The study was designed to assess the safety and efficacy of iron deficiency anaemia (IDA) correction with intravenous ferric carboxymaltose in pregnant women with mild, moderate and severe anaemia in the second and third trimester. Prospective observational study; 65 anaemic pregnant women received ferric carboxymaltose up to 15 mg/kg between 24 and 40 weeks of pregnancy (median 35 weeks gestational age, SD 3.6). Treatment effectiveness was assessed by repeat haemoglobin (Hb) measurements and patient report of well-being in the postpartum period. Safety was assessed by analysis of adverse drug reactions and fetal heart rate monitoring during the infusion. Intravenous ferric carboxymaltose infusion significantly increased Hb values (p < 0.01) above baseline levels in all women. Increased Hb values were observed at 3 and 6 weeks post infusion and up to 8 weeks post-infusion. Ferritin values increased significantly after the infusion. Only 4 women had repeat ferritin values post-partum which remained above baseline levels. Fetal heart rate monitoring did not indicate a drug related negative impact on the fetus. Of the 29 (44.6%) women interviewed, 19 (65.5%) women reported an improvement in their well-being and 9 (31%) felt no different after the infusion. None of the women felt worse. No serious adverse effects were found and minor side effects occurred in 13 (20%) patients. Our prospective data is consistent with existing observational reports of the safe and effective use of ferric carboxymaltose in the treatment of iron deficiency anaemia in pregnancy.
Tiedeken, Jessica A; Ramsdell, John S
2010-04-01
Fetal poisoning of California sea lions (CSLs; Zalophus californianus) has been associated with exposure to the algal toxin domoic acid. These same sea lions accumulate a mixture of persistent environmental contaminants including pesticides and industrial products such as polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs). Developmental exposure to the pesticide dichlorodiphenyltrichloroethane (DDT) and its stable metabolite 1,1-bis-(4-chlorophenyl)-2,2-dichloroethene (p,p -DDE) has been shown to enhance domoic acid-induced seizures in zebrafish; however, the contribution of other co-occurring contaminants is unknown. We formulated a mixture of contaminants to include PCBs, PBDEs, hexachlorocyclohexane (HCH), and chlordane at levels matching those reported for fetal CSL blubber to determine the impact of co-occurring persistent contaminants with p,p -DDE on chemically induced seizures in zebrafish as a model for the CSLs. Embryos were exposed (6-30 hr postfertilization) to p,p -DDE in the presence or absence of a defined contaminant mixture prior to neurodevelopment via either bath exposure or embryo yolk sac microinjection. After brain maturation (7 days postfertilization), fish were exposed to a chemical convulsant, either pentylenetetrazole or domoic acid; resulting seizure behavior was then monitored and analyzed for changes, using cameras and behavioral tracking software. Induced seizure behavior did not differ significantly between subjects with embryonic exposure to a contaminant mixture and those exposed to p,p -DDE only. These studies demonstrate that p,p -DDE--in the absence of PCBs, HCH, chlordane, and PBDEs that co-occur in fetal sea lions--accounts for the synergistic activity that leads to greater sensitivity to domoic acid seizures.
Karalexi, M A; Dessypris, N; Skalkidou, A; Biniaris-Georgallis, S -I; Kalogirou, Ε Ι; Thomopoulos, T P; Herlenius, E; Spector, L G; Loutradis, D; Chrousos, G P; Petridou, E Th
2017-06-01
History of fetal loss including miscarriage and stillbirth has been inconsistently associated with childhood (0-14 years) leukemia in subsequent offspring. A quantitative synthesis of the inconclusive literature by leukemia subtype was therefore conducted. Eligible studies (N = 32) were identified through the screening of over 3500 publications. Random-effects meta-analyses were conducted on the association of miscarriage/stillbirth history with overall (AL; 18,868 cases/35,685 controls), acute lymphoblastic (ALL; 16,150 cases/38,655 controls), and myeloid (AML; 3042 cases/32,997 controls) leukemia. Sensitivity and subgroup analyses by age and ALL subtype, as well as meta-regression were undertaken. Fetal loss history was associated with increased AL risk [Odds Ratio (OR) 1.10, 95% Confidence Intervals (CI) 1.04-1.18]. The positive association was seen for ALL (OR 1.12, 95%CI 1.05-1.19) and for AML (OR 1.13, 95%CI 0.91-1.41); for the latter the OR increased in sensitivity analyses. Notably, stillbirth history was significantly linked to ALL risk (OR 1.33, 95%CI 1.02-1.74), but not AML. By contrast, the association of ALL and AML with previous miscarriage reached marginal significance. The association of miscarriage history was strongest in infant ALL (OR 2.34, 95%CI 1.19-4.60). In this meta-analysis involving >50,000 children, we found noteworthy associations by indices of fetal loss, age at diagnosis, and leukemia type; namely, of stillbirth with ALL and miscarriage history with infant ALL. Elucidation of plausible underlying mechanisms may provide insight into leukemia pathogenesis and indicate monitoring interventions prior to and during pregnancy.
Stern, Judy E; Gopal, Daksha; Liberman, Rebecca F; Anderka, Marlene; Kotelchuck, Milton; Luke, Barbara
2016-09-01
To assess the validity of outcome data reported to the Society for Assisted Reproductive Technology Clinic Outcome Reporting System (SART CORS) compared with data from vital records and the birth defects registry in Massachusetts. Longitudinal cohort. Not applicable. A total of 342,035 live births and fetal deaths from Massachusetts mothers giving birth in the state from July 1, 2004, to December 31, 2008; 9,092 births and fetal deaths were from mothers who had conceived with the use of assisted reproductive technology (ART) and whose cycle data had been reported to the SART CORS. Not applicable. Percentage agreement between maternal race and ethnicity, delivery outcome (live birth or fetal death), plurality (singleton, twin, or triplet+), delivery date, and singleton birth weight reported in the SART CORS versus vital records; sensitivity and specificity for birth defects among singletons as reported in the SART CORS versus the Massachusetts Birth Defects Monitoring Program (BDMP). There was >95% agreement between the SART CORS and vital records for fields of maternal race/ethnicity, live birth/fetal death, and plurality; birth outcome date was within 1 day with 94.9% agreement and birth weight was within 100 g with 89.6% agreement. In contrast, sensitivity for report of any birth defect was 38.6%, with a range of 18.4%-50.0%, for specific birth defect categories. Although most SART CORS outcome fields are accurately reported, birth defect variables showed poor sensitivity compared with the gold standard data from the BDMP. We suggest that reporting of birth defects be discontinued. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Maturation of the Mitochondrial Redox Response to Profound Asphyxia in Fetal Sheep
Drury, Paul P.; Bennet, Laura; Booth, Lindsea C.; Davidson, Joanne O.; Wassink, Guido; Gunn, Alistair J.
2012-01-01
Fetal susceptibility to hypoxic brain injury increases over the last third of gestation. This study examined the hypothesis that this is associated with impaired mitochondrial adaptation, as measured by more rapid oxidation of cytochrome oxidase (CytOx) during profound asphyxia. Methods: Chronically instrumented fetal sheep at 0.6, 0.7, and 0.85 gestation were subjected to either 30 min (0.6 gestational age (ga), n = 6), 25 min (0.7 ga, n = 27) or 15 min (0.85 ga, n = 17) of complete umbilical cord occlusion. Fetal EEG, cerebral impedance (to measure brain swelling) and near-infrared spectroscopy-derived intra-cerebral oxygenation (ΔHb = HbO2 – Hb), total hemoglobin (THb) and CytOx redox state were monitored continuously. Occlusion was associated with profound, rapid fall in ΔHb in all groups to a plateau from 6 min, greatest at 0.85 ga compared to 0.6 and 0.7 ga (p<0.05). THb initially increased at all ages, with the greatest rise at 0.85 ga (p<0.05), followed by a progressive fall from 7 min in all groups. CytOx initially increased in all groups with the greatest rise at 0.85 ga (p<0.05), followed by a further, delayed increase in preterm fetuses, but a striking fall in the 0.85 group after 6 min of occlusion. Cerebral impedance (a measure of cytotoxic edema) increased earlier and more rapidly with greater gestation. In conclusion, the more rapid rise in CytOx and cortical impedance during profound asphyxia with greater maturation is consistent with increasing dependence on oxidative metabolism leading to earlier onset of neural energy failure before the onset of systemic hypotension. PMID:22720088
Abbasi, Hamid; Bennet, Laura; Gunn, Alistair J; Unsworth, Charles P
2016-08-01
Perinatal hypoxic-ischemic encephalopathy (HIE) around the time of birth due to lack of oxygen can lead to debilitating neurological conditions such as epilepsy and cerebral palsy. Experimental data have shown that brain injury evolves over time, but during the first 6-8 hours after HIE the brain has recovered oxidative metabolism in a latent phase, and brain injury is reversible. Treatments such as therapeutic cerebral hypothermia (brain cooling) are effective when started during the latent phase, and continued for several days. Effectiveness of hypothermia is lost if started after the latent phase. Post occlusion monitoring of particular micro-scale transients in the hypoxic-ischemic (HI) Electroencephalogram (EEG), from an asphyxiated fetal sheep model in utero, could provide precursory evidence to identify potential biomarkers of injury when brain damage is still treatable. In our studies, we have reported how it is possible to automatically detect HI EEG transients in the form of spikes and sharp waves during the latent phase of the HI EEG of the preterm fetal sheep. This paper describes how to identify stereotypic evolving micro-scale seizures (SEMS) which have a relatively abrupt onset and termination in a frequency range of 1.8-3Hz (Delta waves) superimposed on a suppressed EEG amplitude background post occlusion. This research demonstrates how a Wavelet Type-II Fuzzy Logic System (WT-Type-II-FLS) can be used to automatically identify subtle abnormal SEMS that occur during the latent phase with a preliminary average validation overall performance of 78.71%±6.63 over the 390 minutes of the latent phase, post insult, using in utero pre-term hypoxic fetal sheep models.
Chan, W S; Anand, S; Ginsberg, J S
2000-01-24
The management of women with prosthetic heart valves during pregnancy poses a particular challenge as there are no available controlled clinical trials to provide guidelines for effective antithrombotic therapy. Oral anticoagulants such as warfarin sodium cause fetal embryopathy; subcutaneous administration of heparin sodium has been reported to be ineffective in preventing thromboembolic complications. To identify the risks of maternal and fetal complications in women with mechanical heart valves treated with different anticoagulation regimens during pregnancy. We performed a systematic review of the literature to determine pooled estimates of maternal and fetal risks associated with the 3 commonly used approaches: (1) oral anticoagulants (OA) throughout pregnancy, (2) replacing OA with heparin in the first trimester (from 6-12 weeks' gestation), and (3) heparin use throughout pregnancy. Fetal outcomes included spontaneous abortions and fetopathic effects, and maternal outcomes were major bleeding, thromboembolic complications, and death. The use of OA throughout pregnancy is associated with warfarin embryopathy in 6.4% (95% confidence interval [CI], 4.6%-8.9%) of livebirths. The substitution of heparin at or prior to 6 weeks, and continued until 12 weeks, eliminated this risk. Overall risks for fetal wastage (spontaneous abortion, stillbirths, and neonatal deaths) were similar in women treated with OA throughout, compared with women treated with heparin in the first trimester. Maternal mortality was 2.9% (95% CI, 1.9%-4.2%). Maj or bleeding events occurred in 2.5% (95% CI, 1.7%-3.5%) of all pregnancies, most at the time of delivery. The regimen associated with the lowest risk of valve thrombosis (3.9%; 95% CI, 2.9-5.9%) was the use of OA throughout; using heparin only between 6 and 12 weeks' gestation was associated with an increased risk of valve thrombosis (9.2%; 95% CI, 5.9%-13.9%). Thromboembolic prophylaxis of women with mechanical heart valves during pregnancy is best achieved with OA; however, this increases the risk of fetal embryopathy. Substituting OA with heparin between 6 and 12 weeks reduces the risk of fetopathic effects, but with an increased risk of thromboembolic complications. The use of low-dose heparin is definitely inadequate; the use of adjusted-dose heparin warrants aggressive monitoring and appropriate dose adjustment. Large prospective trials to determine the best regimen for these women are needed.
Lobato, Gustavo; Soncini, Cristina Silveira
2008-01-01
To evaluate the influence of fetal hydrops and other variables on fetal hematocrit (Hct) decrease after the first intrauterine transfusion (IUT) in alloimmunized pregnancies. From 1996 to 2006, the data of all alloimmunized pregnancies submitted to IUT were assessed. Exclusion criteria included: fetuses submitted to intraperitoneal transfusion; pregnancies complicated by other fetal abnormalities; pregnancies submitted to only one IUT, and cases in which posttransfusion or pretransfusion blood samples were not obtained. Linear regression models were implemented to assess the relationship between the rate of Hct fall after the first IUT and the following variables: fetal hydrops; antibody titer; gestational age at the first IUT; number of days between the first and second IUT; pretransfusion and posttransfusion fetal Hct values. Fifty fetuses fulfilled the study criteria. The fetal Hct decrease after the first IUT was 1.21 (range 0.18-2.3) %/day. The variables independently associated with the fetal Hct drop after the first IUT were the fetal hydrops (p = 0.000), the pretransfusion fetal Hct (p = 0.001) and the posttransfusion fetal Hct (p = 0.016). Fetal hydrops, pretransfusion fetal Hct and posttransfusion fetal Hct seem to influence the fetal Hct decrease between the first and second IUT. These findings may be helpful for estimating the rate of fetal Hct drop and programming the following IUT. Copyright 2008 S. Karger AG, Basel.
Increasing fetal ovine number per gestation alters fetal plasma clinical chemistry values.
Zywicki, Micaela; Blohowiak, Sharon E; Magness, Ronald R; Segar, Jeffrey L; Kling, Pamela J
2016-08-01
Intrauterine growth restriction (IUGR) is interconnected with developmental programming of lifelong pathophysiology. IUGR is seen in human multifetal pregnancies, with stepwise rises in fetal numbers interfering with placental nutrient delivery. It remains unknown whether fetal blood analyses would reflect fetal nutrition, liver, and excretory function in the last trimester of human or ovine IUGR In an ovine model, we hypothesized that fetal plasma biochemical values would reflect progressive placental, fetal liver, and fetal kidney dysfunction as the number of fetuses per gestation rose. To determine fetal plasma biochemical values in singleton, twin, triplet, and quadruplet/quintuplet ovine gestation, we investigated morphometric measures and comprehensive metabolic panels with nutritional measures, liver enzymes, and placental and fetal kidney excretory measures at gestational day (GD) 130 (90% gestation). As anticipated, placental dysfunction was supported by a stepwise fall in fetal weight, fetal plasma glucose, and triglyceride levels as fetal number per ewe rose. Fetal glucose and triglycerides were directly related to fetal weight. Plasma creatinine, reflecting fetal renal excretory function, and plasma cholesterol, reflecting placental excretory function, were inversely correlated with fetal weight. Progressive biochemical disturbances and growth restriction accompanied the rise in fetal number. Understanding the compensatory and adaptive responses of growth-restricted fetuses at the biochemical level may help explain how metabolic pathways in growth restriction can be predetermined at birth. This physiological understanding is important for clinical care and generating interventional strategies to prevent altered developmental programming in multifetal gestation. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.
Claims for compensation after alleged birth asphyxia: a nationwide study covering 15 years.
Andreasen, Stine; Backe, Bjørn; Øian, Pål
2014-02-01
To analyze compensation claims with neurological sequela or death following alleged birth asphyxia. A cohort study. A nationwide study in Norway. All claims made to The Norwegian System of Compensation to Patients (NPE) concerning sequela related to alleged birth asphyxia, between 1994 and 2008. A total of 315 claims of which 161 were awarded compensation. Examination of hospital records, experts' assessments and the decisions made by the NPE, the appeal body and courts of law. Characteristics of deliveries resulting in intrapartum asphyxia and causes of substandard care categorized in eight groups. In the 161 compensated cases, 107 children survived (96 with neurological sequela), and 54 children died. Human error was a frequent reason of substandard care, seen as inadequate fetal monitoring (50%), lack of clinical knowledge and skills (14%), noncompliance with clinical guidelines (11%), failure in referral for senior medical help (10%) and error in drug administration (4%). System errors were registered in only 3%, seen as poor organization of the department, lack of guidelines and time conflicts. The health personnel held responsible for substandard care was an obstetrician in 49% and a midwife in 46%. Substandard care is common in birth asphyxia, and human error is the cause in most cases. Inadequate fetal monitoring and lack of clinical knowledge and skills are the most frequent reasons for compensation after birth asphyxia. © 2013 Nordic Federation of Societies of Obstetrics and Gynecology.
Alfirevic, Zarko; Devane, Declan; Gyte, Gillian Ml; Cuthbert, Anna
2017-02-03
Cardiotocography (CTG) records changes in the fetal heart rate and their temporal relationship to uterine contractions. The aim is to identify babies who may be short of oxygen (hypoxic) to guide additional assessments of fetal wellbeing, or determine if the baby needs to be delivered by caesarean section or instrumental vaginal birth. This is an update of a review previously published in 2013, 2006 and 2001. To evaluate the effectiveness and safety of continuous cardiotocography when used as a method to monitor fetal wellbeing during labour. We searched the Cochrane Pregnancy and Childbirth Group Trials Register (30 November 2016) and reference lists of retrieved studies. Randomised and quasi-randomised controlled trials involving a comparison of continuous cardiotocography (with and without fetal blood sampling) with no fetal monitoring, intermittent auscultation intermittent cardiotocography. Two review authors independently assessed study eligibility, quality and extracted data from included studies. Data were checked for accuracy. We included 13 trials involving over 37,000 women. No new studies were included in this update.One trial (4044 women) compared continuous CTG with intermittent CTG, all other trials compared continuous CTG with intermittent auscultation. No data were found comparing no fetal monitoring with continuous CTG. Overall, methodological quality was mixed. All included studies were at high risk of performance bias, unclear or high risk of detection bias, and unclear risk of reporting bias. Only two trials were assessed at high methodological quality.Compared with intermittent auscultation, continuous cardiotocography showed no significant improvement in overall perinatal death rate (risk ratio (RR) 0.86, 95% confidence interval (CI) 0.59 to 1.23, N = 33,513, 11 trials, low quality evidence), but was associated with halving neonatal seizure rates (RR 0.50, 95% CI 0.31 to 0.80, N = 32,386, 9 trials, moderate quality evidence). There was no difference in cerebral palsy rates (RR 1.75, 95% CI 0.84 to 3.63, N = 13,252, 2 trials, low quality evidence). There was an increase in caesarean sections associated with continuous CTG (RR 1.63, 95% CI 1.29 to 2.07, N = 18,861, 11 trials, low quality evidence). Women were also more likely to have instrumental vaginal births (RR 1.15, 95% CI 1.01 to 1.33, N = 18,615, 10 trials, low quality evidence). There was no difference in the incidence of cord blood acidosis (RR 0.92, 95% CI 0.27 to 3.11, N = 2494, 2 trials, very low quality evidence) or use of any pharmacological analgesia (RR 0.98, 95% CI 0.88 to 1.09, N = 1677, 3 trials, low quality evidence).Compared with intermittent CTG, continuous CTG made no difference to caesarean section rates (RR 1.29, 95% CI 0.84 to 1.97, N = 4044, 1 trial) or instrumental births (RR 1.16, 95% CI 0.92 to 1.46, N = 4044, 1 trial). Less cord blood acidosis was observed in women who had intermittent CTG, however, this result could have been due to chance (RR 1.43, 95% CI 0.95 to 2.14, N = 4044, 1 trial).Data for low risk, high risk, preterm pregnancy and high-quality trials subgroups were consistent with overall results. Access to fetal blood sampling did not appear to influence differences in neonatal seizures or other outcomes.Evidence was assessed using GRADE. Most outcomes were graded as low quality evidence (rates of perinatal death, cerebral palsy, caesarean section, instrumental vaginal births, and any pharmacological analgesia), and downgraded for limitations in design, inconsistency and imprecision of results. The remaining outcomes were downgraded to moderate quality (neonatal seizures) and very low quality (cord blood acidosis) due to similar concerns over limitations in design, inconsistency and imprecision. CTG during labour is associated with reduced rates of neonatal seizures, but no clear differences in cerebral palsy, infant mortality or other standard measures of neonatal wellbeing. However, continuous CTG was associated with an increase in caesarean sections and instrumental vaginal births. The challenge is how best to convey these results to women to enable them to make an informed decision without compromising the normality of labour.The question remains as to whether future randomised trials should measure efficacy (the intrinsic value of continuous CTG in trying to prevent adverse neonatal outcomes under optimal clinical conditions) or effectiveness (the effect of this technique in routine clinical practice).Along with the need for further investigations into long-term effects of operative births for women and babies, much remains to be learned about the causation and possible links between antenatal or intrapartum events, neonatal seizures and long-term neurodevelopmental outcomes, whilst considering changes in clinical practice over the intervening years (one-to-one-support during labour, caesarean section rates). The large number of babies randomised to the trials in this review have now reached adulthood and could potentially provide a unique opportunity to clarify if a reduction in neonatal seizures is something inconsequential that should not greatly influence women's and clinicians' choices, or if seizure reduction leads to long-term benefits for babies. Defining meaningful neurological and behavioural outcomes that could be measured in large cohorts of young adults poses huge challenges. However, it is important to collect data from these women and babies while medical records still exist, where possible describe women's mobility and positions during labour and birth, and clarify if these might impact on outcomes. Research should also address the possible contribution of the supine position to adverse outcomes for babies, and assess whether the use of mobility and positions can further reduce the low incidence of neonatal seizures and improve psychological outcomes for women.
Fetal short time variation during labor: a non-invasive alternative to fetal scalp pH measurements?
Schiermeier, Sven; Reinhard, Joscha; Hatzmann, Hendrike; Zimmermann, Ralf C; Westhof, Gregor
2009-01-01
To determine whether short time variation (STV) of fetal heart beat correlates with scalp pH measurements during labor. From 1279 deliveries, 197 women had at least one fetal scalp pH measurement. Using the CTG-Player, STVs were calculated from the electronically saved cardiotocography (CTG) traces and related to the fetal scalp pH measurements. There was no correlation between STV and fetal scalp pH measurements (r=-0.0592). Fetal STV is an important parameter with high sensitivity for antenatal fetal acidosis. This study shows that STV calculations do not correlate with fetal scalp pH measurements during labor, hence are not helpful in identifying fetal acidosis.
Giambi, C; Montaño-Remacha, C; Celentano, L Pastore; Derrough, T
2015-09-11
Rubella elimination and congenital rubella syndrome (CRS) prevention are targets for achievement by 2015 in the WHO-EURO Region. This paper describes the existing surveillance systems for CRS and rubella in pregnancy in order to critically interpret the findings in relation to the 2012 WHO-EURO surveillance guidelines. In 2012 we conducted a survey to collect information on surveillance of CRS and rubella in pregnancy in 29 EU/EEA countries. Questionnaires explored the characteristics of the surveillance systems, case definition, epidemiological investigation and follow-up of cases, reference laboratories and types of tests performed. Twenty-eight countries had surveillance systems for CRS, mostly nationwide, mandatory, passive and case-based; 23 collected information on the origin of the infection; 11 reported asymptomatic infections; 6 required zero-reporting. Case definitions varied among countries, although 24 used the EU definition. Laboratories reported cases in 18 countries. Twenty countries collected information on pregnancy within the rubella surveillance system and 5 had specific surveillance for rubella in pregnancy. Two countries did not monitor outcomes of suspected infections in pregnancy; infants with CRS were monitored in all the remaining countries; asymptomatic infected infants in 15; stillbirths and fetal deaths in 13; therapeutic and spontaneous abortions in 8 and 7. Twenty-seven countries had a national reference laboratory for CRS and rubella in pregnancy; genotyping was performed in 15. The current surveillance systems allow adequate CRS monitoring in EU. Further efforts are needed to improve their quality, including uniform case definitions, collection of information on the origin of infection, and promotion of reporting from laboratories. Follow-up of pregnant women with suspected infection should be strengthened because it is an entry point for CRS, including detection of fetal deaths, stillbirths and abortions. Laboratory capacity for confirming congenital rubella infections and infections in pregnancy is good in EU, however the use of genotyping should be encouraged. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ebersole, Jeffery L.; de Villiers, Willem J. S.
2014-01-01
Objectives and design Microbial products can act via stress-induced signaling cascades to link dysregulated endogenous microbiota to immune activation (e.g., macrophages) and pregnancy loss. Our previous studies demonstrated that mice deficient in the macrophage pattern recognition scavenger receptors, SR-A and CD36, are more susceptible to inflammatory complications including gut leakiness and experimental colitis. We hypothesized that bacterial penetration of the maternal mucosal surfaces and replication in embryonic fluids compromise the fetal status and can result in miscarriage. Materials and methods Eighty pregnant ICR and SR-A/CD36-deficient mice were injected via tail vein or intraperitoneally with commensal bacteria (Streptococcus cricetus and/or Actinobacillus sp.) or sham controls. Dams were monitored daily for physical distress, pain and abortion. Results Dams injected with single dose bacterial inoculum did not develop clinical symptoms. Day old pups injected with bacteria developed internal focal abscesses, lost weight but recovered after 1 week. Dams receiving a second bacterial inoculum delivered dead fetuses. However, SR-A/CD36-deficnet dams demonstrated 100% fetal death via aborted fetuses, and significant up-regulation of the proinflammatory markers (IL-6, serum Amyloid A) 24–74 h after single inoculum. Conclusions These data indicate that macrophage scavenger receptors are required for the fetal protection against microbial attack and support that maternal transfer of innate immunity contributes to this protection. PMID:20711846
Pisani, Cédric; Rascol, Estelle; Dorandeu, Christophe; Gaillard, Jean-Charles; Charnay, Clarence; Guari, Yannick; Chopineau, Joël; Armengaud, Jean; Devoisselle, Jean-Marie; Prat, Odette
2017-01-01
The formation of a protein corona around nanoparticles can influence their toxicity, triggering cellular responses that may be totally different from those elicited by pristine nanoparticles. The main objective of this study was to investigate whether the species origin of the serum proteins forming the corona influences the in vitro toxicity assessment of silica nanoparticles. Coronas were preformed around nanoparticles before cell exposures by incubation in fetal bovine (FBS) or human (HS) serum. The compositions of these protein coronas were assessed by nano-LC MS/MS. The effects of these protein-coated nanoparticles on HepG2 cells were monitored using real-time cell impedance technology. The nanoparticle coronas formed in human or fetal bovine serum comprised many homologous proteins. Using human compared with fetal bovine serum, nanoparticle toxicity in HepG2 cells decreased by 4-fold and 1.5-fold, when used at 50 and 10μg/mL, respectively. It is likely that "markers of self" are present in the serum and are recognized by human cell receptors. Preforming a corona with human serum seems to be more appropriate for in vitro toxicity testing of potential nanocarriers using human cells. In vitro cytotoxicity assays must reflect in vivo conditions as closely as possible to provide solid and useful results.
Perrotin, F; Simon, E G; Potin, J; Laffon, M
2013-12-01
The purpose of this paper is to review available data regarding the management of delivery in intra uterine growth retarded fetuses and try to get recommendations for clinical obstetrical practice. Bibliographic research performed by consulting PubMed database and recommendations from scientific societies with the following words: small for gestational age, intra-uterine growth restriction, fetal growth restriction, very low birth weight infants, as well as mode of delivery, induction of labor, cesarean section and operative delivery. The diagnosis of severe IUGR justifies the orientation of the patient to a referral centre with all necessary resources for very low birth weight or premature infants Administration of corticosteroids for fetal maturation (before 34 WG) and a possible neuroprotective treatment by with magnesium sulphate (before 32-33 WG) should be discussed. Although elective caesarean section is common, there is no current evidence supporting the use of systematic cesarean section, especially when the woman is in labor. Induction of labor, even with unfavorable cervix is possible under continuous FHR monitoring, in favorable obstetric situations and in the absence of severe fetal hemodynamic disturbances. Instrumental delivery and routine episiotomy are not recommended. For caesarean section under spinal anesthesia, an adequate anesthetic management must ensure the maintenance of basal blood pressure. Compared with appropriate for gestational age fetus, IUGR fetus is at increased risk of metabolic acidosis or perinatal asphyxia during delivery. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Gilhar, A; Ullmann, Y; Shalagino, R; Weisinger, G
1998-01-01
Whether the impact of skin biological age on cytokine expression is a result of this tissue's proliferation potential or not is an important issue in dermatology. We investigated these questions by monitoring cytokine marker mRNA expression from human skin samples from healthy groups of individuals. The skin samples studied represented three age groups: fetal (17-21 weeks), young (18-35 years) and aged (76-88 years). Furthermore, upon skin transplantation of tissue from different age groups onto nude mice, we investigated whether cytokine marker RNA levels would change or normalize. Interestingly, both TNF-alpha and P53 mRNA showed a similar pattern of expression. Both were significantly higher in fetal skin (p < 0.0001 and p < 0.05, respectively), and no difference was noted between aged versus young skin. In contrast to this, IL1-alpha mRNA was expressed at its lowest and highest levels in fetal and young skin, respectively. Following skin transplantation, cytokines and P53 mRNA expression were normalized to similar levels in all age groups. This study implies that when cytokine expression was determined directly at the mRNA level, post-natal expression was not significantly different at either age group. Furthermore, it seems that the environmental conditions surrounding the grafted human skin found on nude mice encouraged normalization of donor cytokine expression.
Seasonal ambient air pollution correlates strongly with spontaneous abortion in Mongolia
2014-01-01
Background Air pollution is a major health challenge worldwide and has previously been strongly associated with adverse reproductive health. This study aimed to examine the association between spontaneous abortion and seasonal variation of air pollutants in Ulaanbaatar, Mongolia. Methods Monthly average O3, SO2, NO2, CO, PM10 and PM2.5 levels were measured at Mongolian Government Air Quality Monitoring stations. The medical records of 1219 women admitted to the hospital due to spontaneous abortion between 2009–2011 were examined retrospectively. Fetal deaths per calendar month from January-December, 2011 were counted and correlated with mean monthly levels of various air pollutants by means of regression analysis. Results Regression of ambient pollutants against fetal death as a dose–response toxicity curve revealed very strong dose–response correlations for SO2 r > 0.9 (p < 0.001) while similarly strongly significant correlation coefficients were found for NO2 (r > 0.8), CO (r > 0.9), PM10 (r > 0.9) and PM2.5 (r > 0.8), (p < 0.001), indicating a strong correlation between air pollution and decreased fetal wellbeing. Conclusion The present study identified alarmingly strong statistical correlations between ambient air pollutants and spontaneous abortion. Further studies need to be done to examine possible correlations between personal exposure to air pollutants and pregnancy loss. PMID:24758249
Multivariate analyses applied to fetal, neonatal and pediatric MRI of neurodevelopmental disorders
Levman, Jacob; Takahashi, Emi
2015-01-01
Multivariate analysis (MVA) is a class of statistical and pattern recognition methods that involve the processing of data that contains multiple measurements per sample. MVA can be used to address a wide variety of medical neuroimaging-related challenges including identifying variables associated with a measure of clinical importance (i.e. patient outcome), creating diagnostic tests, assisting in characterizing developmental disorders, understanding disease etiology, development and progression, assisting in treatment monitoring and much more. Compared to adults, imaging of developing immature brains has attracted less attention from MVA researchers. However, remarkable MVA research growth has occurred in recent years. This paper presents the results of a systematic review of the literature focusing on MVA technologies applied to neurodevelopmental disorders in fetal, neonatal and pediatric magnetic resonance imaging (MRI) of the brain. The goal of this manuscript is to provide a concise review of the state of the scientific literature on studies employing brain MRI and MVA in a pre-adult population. Neurological developmental disorders addressed in the MVA research contained in this review include autism spectrum disorder, attention deficit hyperactivity disorder, epilepsy, schizophrenia and more. While the results of this review demonstrate considerable interest from the scientific community in applications of MVA technologies in pediatric/neonatal/fetal brain MRI, the field is still young and considerable research growth remains ahead of us. PMID:26640765
Multivariate analyses applied to fetal, neonatal and pediatric MRI of neurodevelopmental disorders.
Levman, Jacob; Takahashi, Emi
2015-01-01
Multivariate analysis (MVA) is a class of statistical and pattern recognition methods that involve the processing of data that contains multiple measurements per sample. MVA can be used to address a wide variety of medical neuroimaging-related challenges including identifying variables associated with a measure of clinical importance (i.e. patient outcome), creating diagnostic tests, assisting in characterizing developmental disorders, understanding disease etiology, development and progression, assisting in treatment monitoring and much more. Compared to adults, imaging of developing immature brains has attracted less attention from MVA researchers. However, remarkable MVA research growth has occurred in recent years. This paper presents the results of a systematic review of the literature focusing on MVA technologies applied to neurodevelopmental disorders in fetal, neonatal and pediatric magnetic resonance imaging (MRI) of the brain. The goal of this manuscript is to provide a concise review of the state of the scientific literature on studies employing brain MRI and MVA in a pre-adult population. Neurological developmental disorders addressed in the MVA research contained in this review include autism spectrum disorder, attention deficit hyperactivity disorder, epilepsy, schizophrenia and more. While the results of this review demonstrate considerable interest from the scientific community in applications of MVA technologies in pediatric/neonatal/fetal brain MRI, the field is still young and considerable research growth remains ahead of us.
Predictive value of late decelerations for fetal acidemia in unselective low-risk pregnancies.
Sameshima, Hiroshi; Ikenoue, Tsuyomu
2005-01-01
We evaluated the clinical significance of late decelerations (LD) of intrapartum fetal heart rate (FHR) monitoring to detect low pH (< 7.1) in low-risk pregnancies. We selected two secondary and two tertiary-level institutions where 10,030 women delivered. Among them, 5522 were low-risk pregnancies. The last 2 hours of FHR patterns before delivery were interpreted according to the guidelines of the National Institute of Child Health and Human Development. The correlation between the incidence of LD (occasional, < 50%; recurrent, > or = 50%) and severity (reduced baseline FHR accelerations and variability) of LD, and low pH (< 7.1) were evaluated. Statistical analyses included a contingency table with chi2 and the Fisher test, and one-way analysis of variance with the Bonferroni/Dunn test. In the 5522 low-risk pregnancies, 301 showed occasional LD and 99 showed recurrent LD. Blood gases and pH values deteriorated as the incidence of LD increased and as baseline accelerations or variability was decreased. Positive predictive value for low pH (< 7.1) was exponentially elevated from 0% at no deceleration, 1% in occasional LD, and > 50% in recurrent LD with no baseline FHR accelerations and reduced variability. In low-risk pregnancies, information on LD combined with acceleration and baseline variability enables us to predict the potential incidence of fetal acidemia.
Heimstad, Runa; Skogvoll, Eirik; Mattsson, Lars-Ake; Johansen, Ole Jakob; Eik-Nes, Sturla H; Salvesen, Kjell A
2007-03-01
To compare induction of labor at gestational age 41 weeks with expectant management in regard to neonatal morbidity. Secondary aims were to assess the effect of these managements on mode of delivery and maternal complications. Between September 2002 and July 2004, postterm women with singleton cephalic presentation and no prelabor rupture of membranes were randomly assigned to induction of labor at 289 days or antenatal fetal surveillance every third day until spontaneous labor. Main outcome measures were neonatal morbidity, operative delivery rates, and maternal complications. Five hundred eight women were randomly assigned, 254 in each group. No differences of clinical importance were observed in women in whom labor was induced compared with women who were expectantly managed with regard to the following outcomes: neonates whose 5-minute Apgar score was less than 7 (three neonates in the induction group compared with four in the monitoring group, P=.72); neonates whose umbilical cord pH was less than 7 (three compared with two, P=.69); prevalence of cesarean delivery (28 compared with 33, P=.50); or prevalence of operative vaginal delivery (32 compared with 27, P=.49). In the induction group more women had precipitate labors (33 compared with 12, P<.01; number needed to treat was 13), and the duration of second stage of labor was more often less than 15 minutes (94 compared with 56, P<.01; number needed to treat was 7). No differences were found between the induced and monitored groups regarding neonatal morbidity or mode of delivery, and the outcomes were generally good. ClinicalTrials.gov, www.clinicaltrials.gov, NCT00385229. I.
Iodine Deficiency and Iodine Prophylaxis in Pregnancy.
Trofimiuk-Mudlner, Malgorzata; Hubalewska-Dydejczyk, Alicja
2017-01-01
Physiological changes in pregnancy result in increased iodine demand, which may not be met in areas of mild-to-moderate iodine deficiency or borderline sufficiency. As a pregnant woman is the only source of thyroid hormones for her child during early gestation, iodine deficiencyinduced hypothyroxinemia may have deleterious effects on fetal development. To present the current approach to iodine deficiency and its prophylaxis during pregnancy. A review of the current literature including patents on iodine deficiency in pregnancy has been performed. Negative influence of severe iodine deficiency on fetal development has been proved, and evidence on a deleterious impact of milder forms of iodine deficiency on cognition of the offspring is rapidly growing. Although the WHO has addressed the issues of monitoring iodine status during pregnancy, prophylactic measures and assessment of their effectiveness, there are some controversies, regarding for example the best methods for control of iodine status. New patents in urinary iodine measurement methods may make iodine nutrition monitoring easier. The main method of iodine prophylaxis, in pregnancy also, is universal salt iodization. However, particularly if there is not sufficient coverage of the households with iodized salt, additional measures, such as oral supplementation with potassium iodide tablets, are necessary in pregnant women to provide adequate iodine nutrition. Iodine supplementation improves maternal thyroid function indices; particularly, it prevents goiter formation. Stronger evidence on beneficial effects of iodine supplementation of mild-to-moderate iodine deficient pregnant women on cognitive function of their children is still needed. It may be provided by randomized controlled trials and international initiatives. Changes in the iodine prophylaxis system should be monitored, both to prevent decreased or excessive iodine intake. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Rapid cortical oscillations and early motor activity in premature human neonate.
Milh, Mathieu; Kaminska, Anna; Huon, Catherine; Lapillonne, Alexandre; Ben-Ari, Yehezkel; Khazipov, Rustem
2007-07-01
Delta-brush is the dominant pattern of rapid oscillatory activity (8-25 Hz) in the human cortex during the third trimester of gestation. Here, we studied the relationship between delta-brushes in the somatosensory cortex and spontaneous movements of premature human neonates of 29-31 weeks postconceptional age using a combination of scalp electroencephalography and monitoring of motor activity. We found that sporadic hand and foot movements heralded the appearance of delta-brushes in the corresponding areas of the cortex (lateral and medial regions of the contralateral central cortex, respectively). Direct hand and foot stimulation also reliably evoked delta-brushes in the same areas. These results suggest that sensory feedback from spontaneous fetal movements triggers delta-brush oscillations in the central cortex in a somatotopic manner. We propose that in the human fetus in utero, before the brain starts to receive elaborated sensory input from the external world, spontaneous fetal movements provide sensory stimulation and drive delta-brush oscillations in the developing somatosensory cortex contributing to the formation of cortical body maps.
How maternal malnutrition affects linear growth and development in the offspring.
Papathakis, Peggy C; Singh, Lauren N; Manary, Mark J
2016-11-05
Maternal malnutrition is common in the developing world and has detrimental effects on both the mother and infant. Pre-pregnancy nutritional status and weight gain during pregnancy are positively related to fetal growth and development. Internationally, there is no agreement on the method of diagnosis or treatment of moderate or severe malnutrition during pregnancy. Establishing clear guidelines for diagnosis and treatment will be essential in elevating the problem. Possible anthropometric measurements used to detect and monitor maternal malnutrition include pre-pregnancy BMI, weight gain, and mid upper arm circumference. Food supplements have the potential to increase gestational weight gain and energy intake which are positively associated with fetal growth and development. Overall more studies are needed to conclude the impact of food/nutrient supplements on infant growth in undernourished pregnant women in developing countries. Currently, a study underway may provide much needed documentation of the benefits of treating malnutrition in pregnancy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Maternal predictors of intrauterine growth restriction.
Cetin, Irene; Mandò, Chiara; Calabrese, Stefania
2013-05-01
Intrauterine growth restriction (IUGR) occurs when fetal growth rate falls below the genetic potential and affects a significant number of pregnancies, but still no therapy has been developed for this pregnancy disease. This article reviews the most recent findings concerning maternal characteristics and behaviours predisposing to IUGR as well as maternal early markers of the disease. A comprehensive understanding of factors associated with IUGR will help in providing important tools for preventing and understanding adverse outcomes. Maternal nutritional status, diet and exposure to environmental factors are increasingly acknowledged as potential factors affecting fetal growth both by altering nutrient availability to the fetus and by modulating placental gene expression, thus modifying placental function. Assessing nutritional and environmental factors associated with IUGR, and the molecular mechanisms by which they may have a role in the disease onset, is necessary to provide comprehensive and common guidelines for maternal care and recommended behaviours. Moreover, maternal genetic predispositions and early serum markers may allow a better and more specific monitoring of high risk pregnancies, optimizing the timing of delivery.
Advances in early fetal loss research: importance for risk assessment.
Sweeney, A M; LaPorte, R E
1991-01-01
The assessment of early fetal losses (EFLs) in relationship to environmental agents offers unique advantages compared to other end points for hazard assessment. There is a high incidence (greater than 20% of all pregnancies end in an EFL), and the interval between exposure and end point is the short duration between conception and event, i.e., approximately 12 weeks. In contrast, cancer, which is the primary end point evaluated in risk assessment models, occurs with much lower frequency, and the latency period is measured in years or decades. EFLs have not been used effectively for risk assessment because most of the events are not detected. Prospective studies provide the only approach whereby it is possible to link exposure to EFLs. Recent methodologic advancements have demonstrated that it is now possible to conduct population-based studies of EFLs. It is likely that EFLs could serve as sentinels to monitor adverse health effects of many potential environmental hazards. The methodology will be demonstrated using lead exposure in utero as an example. PMID:2050056
Development and clinical evaluation of noninvasive near-infrared monitoring of cerebral oxygenation
NASA Astrophysics Data System (ADS)
Wickramasinghe, Yappa A.; Rolfe, Peter J.; Palmer, Keith; Watkins, S.; Spencer, S. A.; Doyle, M.; O'Brien, S.; Walker, A.; Rice, C.; Smallpeice, C.
1994-02-01
Near infrared spectroscopy (NIRS) is a relatively new method which is suitable for monitoring oxygenation in blood and tissue in the brain of the fetus and the neonate. The technique involves in-vivo determination of the absorption of light in the wavelength range 775 to 900 nm through such tissue and converting such changes in absorbance to provide information about the changes in the concentration of oxygenated and de-oxygenated haemoglobin (HbO2 and Hb). Recent developments of the methodology now enable the calculation of changes in cerebral blood volume (CBV) as well as absolute CBV and cerebral blood flow (CBF). The attraction of this method is its applicability to monitor cerebral function in a wide variety of patient groups. Although primarily developed for neonatal use it is today applied on the fetus to investigate fetal hypoxia and on adults undergoing surgery.
Quadruplet pregnancy: contemporary management and outcome.
Elliott, J P; Radin, T G
1992-09-01
Quadruplets are occurring more frequently as assisted-reproduction techniques improve fertility in couples previously unable to conceive. Ten quadruplet pregnancies cared for in one perinatal practice over 5 years had excellent outcome. The mean gestational age at delivery was 32.5 weeks, compared with approximately 30 weeks in the literature. There were no perinatal deaths and no long-term morbidity. Our patients were compared with a series of 57 consecutive patients with quadruplet pregnancies monitored by a home monitoring system. Parity of 1 or more appeared to improve outcome. Pregnancy-induced hypertension occurred in nine of our pregnancies and necessitated delivery in seven instances. Fetal distress was responsible for two deliveries and uncontrollable preterm labor for only one. Key points in our management protocol include prophylactic use of low-dose aspirin, home contraction monitoring, use of terbutaline pump tocolysis, and bed rest at home starting at 16 weeks.
Henry, A; Welsh, A W
2015-11-01
To investigate use of the fetal myocardial performance index (MPI) in assessing intrahepatic cholestasis of pregnancy (ICP). This was a cohort study including cross-sectional and longitudinal data from 31 women with ICP recruited from June 2012 to March 2014. Fetal left, right and delta MPI (LMPI, RMPI and DMPI), and routine measures of fetal growth and wellbeing, were obtained at each ultrasound examination. Results were evaluated with respect to gestational age (GA)-adjusted reference intervals, level of maternal serum bile acid (SBA) and fetal outcome. Lower SBA (≥ 7.5 and < 40 μmol/L) and high SBA (≥ 40 μmol/L) subgroups of cases were defined for the analysis. A total of 51 ultrasound examinations were performed in 33 fetuses. The mean LMPI, and means of its isovolumetric relaxation time (IRT) and isovolumetric contraction time (ICT) components were significantly higher in all subgroups of cases of ICP relative to the normal reference mean. Considering only the first examination in each case of ICP, IRT was significantly more prolonged in the high SBA group (n = 10) in comparison to the lower SBA group (n = 23) (52.7 ± 8.0 ms vs 47.3 ± 4.8 ms, P = 0.02), and both IRT (r = 0.538, P = 0.001) and LMPI (r = 0.367, P = 0.036) were significantly correlated with SBA concentration. The proportion of high SBA cases with LMPI, RMPI or DMPI > 2 SD above the GA-adjusted reference mean was not significantly greater than for the lower SBA group. On analysis of all data from those cases with more than one examination, no significant correlation was found between SBA concentration and any of the MPI variables. LMPI values increase above the population GA-adjusted mean in cases of ICP, particularly amongst women with higher SBA. A significant correlation between IRT and LMPI at initial examination and increasing SBA concentration was found. A future multicenter prospective study may clarify the prognostic utility of MPI in ICP. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.